Sample records for real time correlation

  1. Real-time software receiver

    NASA Technical Reports Server (NTRS)

    Psiaki, Mark L. (Inventor); Kintner, Jr., Paul M. (Inventor); Ledvina, Brent M. (Inventor); Powell, Steven P. (Inventor)

    2007-01-01

    A real-time software receiver that executes on a general purpose processor. The software receiver includes data acquisition and correlator modules that perform, in place of hardware correlation, baseband mixing and PRN code correlation using bit-wise parallelism.

  2. Real-time software receiver

    NASA Technical Reports Server (NTRS)

    Psiaki, Mark L. (Inventor); Ledvina, Brent M. (Inventor); Powell, Steven P. (Inventor); Kintner, Jr., Paul M. (Inventor)

    2006-01-01

    A real-time software receiver that executes on a general purpose processor. The software receiver includes data acquisition and correlator modules that perform, in place of hardware correlation, baseband mixing and PRN code correlation using bit-wise parallelism.

  3. ALMA Correlator Real-Time Data Processor

    NASA Astrophysics Data System (ADS)

    Pisano, J.; Amestica, R.; Perez, J.

    2005-10-01

    The design of a real-time Linux application utilizing Real-Time Application Interface (RTAI) to process real-time data from the radio astronomy correlator for the Atacama Large Millimeter Array (ALMA) is described. The correlator is a custom-built digital signal processor which computes the cross-correlation function of two digitized signal streams. ALMA will have 64 antennas with 2080 signal streams each with a sample rate of 4 giga-samples per second. The correlator's aggregate data output will be 1 gigabyte per second. The software is defined by hard deadlines with high input and processing data rates, while requiring interfaces to non real-time external computers. The designed computer system - the Correlator Data Processor or CDP, consists of a cluster of 17 SMP computers, 16 of which are compute nodes plus a master controller node all running real-time Linux kernels. Each compute node uses an RTAI kernel module to interface to a 32-bit parallel interface which accepts raw data at 64 megabytes per second in 1 megabyte chunks every 16 milliseconds. These data are transferred to tasks running on multiple CPUs in hard real-time using RTAI's LXRT facility to perform quantization corrections, data windowing, FFTs, and phase corrections for a processing rate of approximately 1 GFLOPS. Highly accurate timing signals are distributed to all seventeen computer nodes in order to synchronize them to other time-dependent devices in the observatory array. RTAI kernel tasks interface to the timing signals providing sub-millisecond timing resolution. The CDP interfaces, via the master node, to other computer systems on an external intra-net for command and control, data storage, and further data (image) processing. The master node accesses these external systems utilizing ALMA Common Software (ACS), a CORBA-based client-server software infrastructure providing logging, monitoring, data delivery, and intra-computer function invocation. The software is being developed in tandem with the correlator hardware which presents software engineering challenges as the hardware evolves. The current status of this project and future goals are also presented.

  4. Real-time envelope cross-correlation detector: application to induced seismicity in the Insheim and Landau deep geothermal reservoirs

    NASA Astrophysics Data System (ADS)

    Vasterling, Margarete; Wegler, Ulrich; Becker, Jan; Brüstle, Andrea; Bischoff, Monika

    2017-01-01

    We develop and test a real-time envelope cross-correlation detector for use in seismic response plans to mitigate hazard of induced seismicity. The incoming seismological data are cross-correlated in real-time with a set of previously recorded master events. For robustness against small changes in the earthquake source locations or in the focal mechanisms we cross-correlate the envelopes of the seismograms rather than the seismograms themselves. Two sequenced detection conditions are implemented: After passing a single trace cross-correlation condition, a network cross-correlation is calculated taking amplitude ratios between stations into account. Besides detecting the earthquake and assigning it to the respective reservoir, real-time magnitudes are important for seismic response plans. We estimate the magnitudes of induced microseismicity using the relative amplitudes between master event and detected event. The real-time detector is implemented as a SeisComP3 module. We carry out offline and online performance tests using seismic monitoring data of the Insheim and Landau geothermal power plants (Upper Rhine Graben, Germany), also including blasts from a nearby quarry. The comparison of the automatic real-time catalogue with a manually processed catalogue shows, that with the implemented parameters events are always correctly assigned to the respective reservoir (4 km distance between reservoirs) or the quarry (8 km and 10 km distance, respectively, from the reservoirs). The real-time catalogue achieves a magnitude of completeness around 0.0. Four per cent of the events assigned to the Insheim reservoir and zero per cent of the Landau events are misdetections. All wrong detections are local tectonic events, whereas none are caused by seismic noise.

  5. The VLBA correlator: Real-time in the distributed era

    NASA Technical Reports Server (NTRS)

    Wells, D. C.

    1992-01-01

    The correlator is the signal processing engine of the Very Long Baseline Array (VLBA). Radio signals are recorded on special wideband (128 Mb/s) digital recorders at the 10 telescopes, with sampling times controlled by hydrogen maser clocks. The magnetic tapes are shipped to the Array Operations Center in Socorro, New Mexico, where they are played back simultaneously into the correlator. Real-time software and firmware controls the playback drives to achieve synchronization, compute models of the wavefront delay, control the numerous modules of the correlator, and record FITS files of the fringe visibilities at the back-end of the correlator. In addition to the more than 3000 custom VLSI chips which handle the massive data flow of the signal processing, the correlator contains a total of more than 100 programmable computers, 8-, 16- and 32-bit CPUs. Code is downloaded into front-end CPU's dependent on operating mode. Low-level code is assembly language, high-level code is C running under a RT OS. We use VxWorks on Motorola MVME147 CPU's. Code development is on a complex of SPARC workstations connected to the RT CPU's by Ethernet. The overall management of the correlation process is dependent on a database management system. We use Ingres running on a Sparcstation-2. We transfer logging information from the database of the VLBA Monitor and Control System to our database using Ingres/NET. Job scripts are computed and are transferred to the real-time computers using NFS, and correlation job execution logs and status flow back by the route. Operator status and control displays use windows on workstations, interfaced to the real-time processes by network protocols. The extensive network protocol support provided by VxWorks is invaluable. The VLBA Correlator's dependence on network protocols is an example of the radical transformation of the real-time world over the past five years. Real-time is becoming more like conventional computing. Paradoxically, 'conventional' computing is also adopting practices from the real-time world: semaphores, shared memory, light-weight threads, and concurrency. This appears to be a convergence of thinking.

  6. Real-Time and Memory Correlation via Acousto-Optic Processing,

    DTIC Science & Technology

    1978-06-01

    acousto - optic technology as an answer to these requirements appears very attractive. Three fundamental signal-processing schemes using the acousto ... optic interaction have been investigated: (i) real-time correlation and convolution, (ii) Fourier and discrete Fourier transformation, and (iii

  7. Real-time optical holographic tracking of multiple objects

    NASA Technical Reports Server (NTRS)

    Chao, Tien-Hsin; Liu, Hua-Kuang

    1989-01-01

    A coherent optical correlation technique for real-time simultaneous tracking of several different objects making independent movements is described, and experimental results are presented. An evaluation of this system compared with digital computing systems is made. The real-time processing capability is obtained through the use of a liquid crystal television spatial light modulator and a dichromated gelatin multifocus hololens. A coded reference beam is utilized in the separation of the output correlation plane associated with each input target so that independent tracking can be achieved.

  8. Time-varying correlations in global real estate markets: A multivariate GARCH with spatial effects approach

    NASA Astrophysics Data System (ADS)

    Gu, Huaying; Liu, Zhixue; Weng, Yingliang

    2017-04-01

    The present study applies the multivariate generalized autoregressive conditional heteroscedasticity (MGARCH) with spatial effects approach for the analysis of the time-varying conditional correlations and contagion effects among global real estate markets. A distinguishing feature of the proposed model is that it can simultaneously capture the spatial interactions and the dynamic conditional correlations compared with the traditional MGARCH models. Results reveal that the estimated dynamic conditional correlations have exhibited significant increases during the global financial crisis from 2007 to 2009, thereby suggesting contagion effects among global real estate markets. The analysis further indicates that the returns of the regional real estate markets that are in close geographic and economic proximities exhibit strong co-movement. In addition, evidence of significantly positive leverage effects in global real estate markets is also determined. The findings have significant implications on global portfolio diversification opportunities and risk management practices.

  9. A real-time monitoring system for the facial nerve.

    PubMed

    Prell, Julian; Rachinger, Jens; Scheller, Christian; Alfieri, Alex; Strauss, Christian; Rampp, Stefan

    2010-06-01

    Damage to the facial nerve during surgery in the cerebellopontine angle is indicated by A-trains, a specific electromyogram pattern. These A-trains can be quantified by the parameter "traintime," which is reliably correlated with postoperative functional outcome. The system presented was designed to monitor traintime in real-time. A dedicated hardware and software platform for automated continuous analysis of the intraoperative facial nerve electromyogram was specifically designed. The automatic detection of A-trains is performed by a software algorithm for real-time analysis of nonstationary biosignals. The system was evaluated in a series of 30 patients operated on for vestibular schwannoma. A-trains can be detected and measured automatically by the described method for real-time analysis. Traintime is monitored continuously via a graphic display and is shown as an absolute numeric value during the operation. It is an expression of overall, cumulated length of A-trains in a given channel; a high correlation between traintime as measured by real-time analysis and functional outcome immediately after the operation (Spearman correlation coefficient [rho] = 0.664, P < .001) and in long-term outcome (rho = 0.631, P < .001) was observed. Automated real-time analysis of the intraoperative facial nerve electromyogram is the first technique capable of reliable continuous real-time monitoring. It can critically contribute to the estimation of functional outcome during the course of the operative procedure.

  10. From truck to optical fibre: the coming-of-age of eVLBI

    NASA Astrophysics Data System (ADS)

    Szomoru, A.; Biggs, A.; Garrett, M.; van Langevelde, H. J.; Olnon, F.; Paragi, Z.; Parsley, S.; Pogrebenko, S.; Reynolds, C.

    Spurred by the advent of disk-based recording systems and the nearly explosive increase of internet bandwidth, eVLBI (Parsley et al. te{parsley}) has undergone a remarkable development over the past two years. From ftp-based transfers of small amounts of astronomical data, through near real-time correlation (disk-buffered at the correlator), it has culminated this spring in the first three telescope real-time correlation at JIVE (Onsala, Westerbork and Jodrell Bank). In this paper we will give a review of this development and the current state of affairs. We will also address the current limitations and the way we may improve both bandwidth and reliability and finally we will discuss the opportunities a true high-bandwidth real-time VLBI correlator will provide. (astro-ph/0412686)

  11. Real-time estimation of prostate tumor rotation and translation with a kV imaging system based on an iterative closest point algorithm.

    PubMed

    Tehrani, Joubin Nasehi; O'Brien, Ricky T; Poulsen, Per Rugaard; Keall, Paul

    2013-12-07

    Previous studies have shown that during cancer radiotherapy a small translation or rotation of the tumor can lead to errors in dose delivery. Current best practice in radiotherapy accounts for tumor translations, but is unable to address rotation due to a lack of a reliable real-time estimate. We have developed a method based on the iterative closest point (ICP) algorithm that can compute rotation from kilovoltage x-ray images acquired during radiation treatment delivery. A total of 11 748 kilovoltage (kV) images acquired from ten patients (one fraction for each patient) were used to evaluate our tumor rotation algorithm. For each kV image, the three dimensional coordinates of three fiducial markers inside the prostate were calculated. The three dimensional coordinates were used as input to the ICP algorithm to calculate the real-time tumor rotation and translation around three axes. The results show that the root mean square error was improved for real-time calculation of tumor displacement from a mean of 0.97 mm with the stand alone translation to a mean of 0.16 mm by adding real-time rotation and translation displacement with the ICP algorithm. The standard deviation (SD) of rotation for the ten patients was 2.3°, 0.89° and 0.72° for rotation around the right-left (RL), anterior-posterior (AP) and superior-inferior (SI) directions respectively. The correlation between all six degrees of freedom showed that the highest correlation belonged to the AP and SI translation with a correlation of 0.67. The second highest correlation in our study was between the rotation around RL and rotation around AP, with a correlation of -0.33. Our real-time algorithm for calculation of rotation also confirms previous studies that have shown the maximum SD belongs to AP translation and rotation around RL. ICP is a reliable and fast algorithm for estimating real-time tumor rotation which could create a pathway to investigational clinical treatment studies requiring real-time measurement and adaptation to tumor rotation.

  12. Real-time estimation of prostate tumor rotation and translation with a kV imaging system based on an iterative closest point algorithm

    NASA Astrophysics Data System (ADS)

    Nasehi Tehrani, Joubin; O'Brien, Ricky T.; Rugaard Poulsen, Per; Keall, Paul

    2013-12-01

    Previous studies have shown that during cancer radiotherapy a small translation or rotation of the tumor can lead to errors in dose delivery. Current best practice in radiotherapy accounts for tumor translations, but is unable to address rotation due to a lack of a reliable real-time estimate. We have developed a method based on the iterative closest point (ICP) algorithm that can compute rotation from kilovoltage x-ray images acquired during radiation treatment delivery. A total of 11 748 kilovoltage (kV) images acquired from ten patients (one fraction for each patient) were used to evaluate our tumor rotation algorithm. For each kV image, the three dimensional coordinates of three fiducial markers inside the prostate were calculated. The three dimensional coordinates were used as input to the ICP algorithm to calculate the real-time tumor rotation and translation around three axes. The results show that the root mean square error was improved for real-time calculation of tumor displacement from a mean of 0.97 mm with the stand alone translation to a mean of 0.16 mm by adding real-time rotation and translation displacement with the ICP algorithm. The standard deviation (SD) of rotation for the ten patients was 2.3°, 0.89° and 0.72° for rotation around the right-left (RL), anterior-posterior (AP) and superior-inferior (SI) directions respectively. The correlation between all six degrees of freedom showed that the highest correlation belonged to the AP and SI translation with a correlation of 0.67. The second highest correlation in our study was between the rotation around RL and rotation around AP, with a correlation of -0.33. Our real-time algorithm for calculation of rotation also confirms previous studies that have shown the maximum SD belongs to AP translation and rotation around RL. ICP is a reliable and fast algorithm for estimating real-time tumor rotation which could create a pathway to investigational clinical treatment studies requiring real-time measurement and adaptation to tumor rotation.

  13. Ultrafast Target Recognition via Super-Parallel Holograph Based Correlator, RAM and Associative Memory

    DTIC Science & Technology

    2008-03-11

    JTC) 2𔃾 based on a dynamic material answers the challenge of fast correlation with large databases. Images retrieved from the SPHRAM and used as the...transform (JTC) and matched spatial filter or VanderLugt ( VLC ) correlators, either of which can be implemented in real-time by degenerate four wave-mixing in...proposed system, consisting of the SPHROM coupled with a shift-invariant real-time VLC . The correlation is performed in the VLC architecture to

  14. Identifying Optimal Temporal Scale for the Correlation of AOD and Ground Measurements of PM2.5 to Improve the Modeling Performance in a Real-Time Air Quality Estimation System

    NASA Technical Reports Server (NTRS)

    Li,Hui; Faruque, Fazlay; Williams, Worth; Al-Hamdan, Mohammad; Luvall, Jeffrey; Crosson, William; Rickman, Douglas; Limaye, Ashutosh

    2008-01-01

    Aerosol optical depth (AOD), derived from satellite measurements using Moderate Resolution Imaging Spectrometer (MODIS), offers indirect estimates of particle matter. Research shows a significant positive correlation between satellite-based measurements of AOD and ground-based measurements of particulate matter with aerodynamic diameter less than or equal to 2.5 micrometers (PM2.5). In addition, satellite observations have also shown great promise in improving estimates of PM2.5 air quality surface. Research shows that correlations between AOD and ground PM2.5 are affected by a combination of many factors such as inherent characteristics of satellite observations, terrain, cloud cover, height of the mixing layer, and weather conditions, and thus might vary widely in different regions, different seasons, and even different days in a same location. Analysis of correlating AOD with ground measured PM2.5 on a day-to-day basis suggests the temporal scale, a number of immediate latest days for a given run's day, for their correlations needs to be considered to improve air quality surface estimates, especially when satellite observations are used in a real-time pollution system. The second reason is that correlation coefficients between AOD and ground PM2.5 cannot be predetermined and needs to be calculated for each day's run for a real-time system because the coefficients can vary over space and time. Few studies have been conducted to explore the optimal way to apply AOD data to improve model accuracies of PM2.5 surface estimation in a real-time air quality system. This paper discusses the best temporal scale to calculate the correlation of AOD and ground particle matter data to improve the results of pollution models in real-time system.

  15. Real-time PCR quantification of Vibrio parahaemolyticus in oysters using an alternative matrix.

    PubMed

    Kaufman, G E; Blackstone, G M; Vickery, M C L; Bej, A K; Bowers, J; Bowen, Michael D; Meyer, Richard F; DePaola, A

    2004-11-01

    This study examined the relationship between levels of total Vibrio parahaemolyticus found in oyster tissues and mantle fluid with the goal of using mantle fluid as a template matrix in a new quantitative real-time PCR assay targeting the thermolabile hemolysin (tlh) gene for the enumeration of total V. parahaemolyticus in oysters. Oysters were collected near Mobile Bay, Ala., in June, July, and September and tested immediately after collection and storage at 26 degrees C for 24 h. Initial experiments using DNA colony hybridization targeting tlh demonstrated that natural V. parahaemolyticus levels in the mantle fluid of individual oysters were strongly correlated (r = 0.85, P < 0.05) with the levels found in their tissues. When known quantities of cultured V. parahaemolyticus cells were added to real-time PCR reactions that contained mantle fluid and oyster tissue matrices separately pooled from multiple oysters, a strong linear correlation was observed between the real-time PCR cycle threshold and the log concentration of cells inoculated into each PCR reaction (mantle fluid: r = 0.98, P < 0.05; and oyster: r = 0.99, P < 0.05). However, the mantle fluid exhibited less inhibition of the PCR amplification than the homogenized oyster tissue. Analysis of natural V. parahaemolyticus populations in mantle fluids using both colony hybridization and real-time PCR demonstrated a significant (P < 0.05) but reduced correlation (r = -0.48) between the two methods. Reductions in the efficiency of the real-time PCR that resulted from low population densities of V. parahaemolyticus and PCR inhibitors present in the mantle fluid of some oysters (with significant oyster-to-oyster variation) contributed to the reduction in correlation between the methods that was observed when testing natural V. parahaemolyticus populations. The V. parahaemolyticus-specific real-time PCR assay used for this study could estimate elevated V. parahaemolyticus levels in oyster mantle fluid within 1 h from sampling time.

  16. Real time monitoring of induced seismicity in the Insheim and Landau deep geothermal reservoirs, Upper Rhine Graben, using the new SeisComP3 cross-correlation detector

    NASA Astrophysics Data System (ADS)

    Vasterling, Margarete; Wegler, Ulrich; Bruestle, Andrea; Becker, Jan

    2016-04-01

    Real time information on the locations and magnitudes of induced earthquakes is essential for response plans based on the magnitude frequency distribution. We developed and tested a real time cross-correlation detector focusing on induced microseismicity in deep geothermal reservoirs. The incoming seismological data are cross-correlated in real time with a set of known master events. We use the envelopes of the seismograms rather than the seismograms themselves to account for small changes in the source locations or in the focal mechanisms. Two different detection conditions are implemented: After first passing a single trace correlation condition, secondly a network correlation is calculated taking the amplitude information of the seismic network into account. The magnitude is estimated by using the respective ratio of the maximum amplitudes of the master event and the detected event. The detector is implemented as a real time tool and put into practice as a SeisComp3 module, an established open source software for seismological real time data handling and analysis. We validated the reliability and robustness of the detector by an offline playback test using four month of data from monitoring the power plant in Insheim (Upper Rhine Graben, SW Germany). Subsequently, in October 2013 the detector was installed as real time monitoring system within the project "MAGS2 - Microseismic Activity of Geothermal Systems". Master events from the two neighboring geothermal power plants in Insheim and Landau and two nearby quarries are defined. After detection, manual phase determination and event location are performed at the local seismological survey of the Geological Survey and Mining Authority of Rhineland-Palatinate. Until November 2015 the detector identified 454 events out of which 95% were assigned correctly to the respective source. 5% were misdetections caused by local tectonic events. To evaluate the completeness of the automatically obtained catalogue, it is compared to the event catalogue of the Seismological Service of Southwestern Germany and to the events reported by the company tasked with seismic monitoring of the Insheim power plant. Events missed by the cross-correlation detector are generally very small. They are registered at too few stations to meet the detection criteria. Most of these small events were not locatable. The automatic catalogue has a magnitude of completeness around 0.0 and is significantly more detailed than the catalogue from standard processing of the Seismological Service of Southwestern Germany for this region. For events in the magnitude range of the master event the magnitude estimated from the amplitude ratio reproduces the local magnitude well. For weaker events there tends to be a small offset. Altogether, the developed real time cross correlation detector provides robust detections with reliable association of the events to the respective sources and valid magnitude estimates. Thus, it provides input parameters for the mitigation of seismic hazard by using response plans in real time.

  17. [Analytical performances of real-time PCR by Abbott RealTime CMV with m2000 for the detection of cytomegalovirus in urine].

    PubMed

    De Monte, Anne; Cannavo, Isabelle; Caramella, Anne; Ollier, Laurence; Giordanengo, Valérie

    2016-01-01

    Congenital cytomegalovirus (CMV) infection is the leading cause of sensoneurinal disability due to infectious congenital disease. The diagnosis of congenital CMV infection is based on the search of CMV in the urine within the first two weeks of life. Viral culture of urine is the gold standard. However, the PCR is highly sensitive and faster. It is becoming an alternative choice. The objective of this study is the validation of real-time PCR by Abbott RealTime CMV with m2000 for the detection of cytomegalovirus in urine. Repeatability, reproducibility, detection limit and inter-sample contamination were evaluated. Urine samples from patients (n=141) were collected and analyzed simultaneously in culture and PCR in order to assess the correlation of these two methods. The sensitivity and specificity of PCR were also calculated. The Abbott RealTime CMV PCR in urine is an automated and sensitive method (detection limit 200 UI/mL). Fidelity is very good (standard deviation of repeatability: 0.08 to 0.15 LogUI/mL and reproducibility 0.18 LogUI/mL). We can note a good correlation between culture and Abbott RealTime CMV PCR (kappa 96%). When considering rapid culture as reference, real-time PCR was highly sensitive (100%) and specific (98.2%). The real-time PCR by Abbott RealTime CMV with m2000 is optimal for CMV detection in urine.

  18. High-resolution correlation

    NASA Astrophysics Data System (ADS)

    Nelson, D. J.

    2007-09-01

    In the basic correlation process a sequence of time-lag-indexed correlation coefficients are computed as the inner or dot product of segments of two signals. The time-lag(s) for which the magnitude of the correlation coefficient sequence is maximized is the estimated relative time delay of the two signals. For discrete sampled signals, the delay estimated in this manner is quantized with the same relative accuracy as the clock used in sampling the signals. In addition, the correlation coefficients are real if the input signals are real. There have been many methods proposed to estimate signal delay to more accuracy than the sample interval of the digitizer clock, with some success. These methods include interpolation of the correlation coefficients, estimation of the signal delay from the group delay function, and beam forming techniques, such as the MUSIC algorithm. For spectral estimation, techniques based on phase differentiation have been popular, but these techniques have apparently not been applied to the correlation problem . We propose a phase based delay estimation method (PBDEM) based on the phase of the correlation function that provides a significant improvement of the accuracy of time delay estimation. In the process, the standard correlation function is first calculated. A time lag error function is then calculated from the correlation phase and is used to interpolate the correlation function. The signal delay is shown to be accurately estimated as the zero crossing of the correlation phase near the index of the peak correlation magnitude. This process is nearly as fast as the conventional correlation function on which it is based. For real valued signals, a simple modification is provided, which results in the same correlation accuracy as is obtained for complex valued signals.

  19. Model for Correlating Real-Time Survey Results to Contaminant Concentrations - 12183

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walker, Stuart A.

    2012-07-01

    The U.S. Environmental Protection Agency (EPA) Superfund program is developing a new Counts Per Minute (CPM) calculator to correlate real-time survey results, which are often expressed as counts per minute, to contaminant concentrations that are more typically provided in risk assessments or for cleanup levels, usually expressed in pCi/g or pCi/m{sup 2}. Currently there is no EPA guidance for Superfund sites on correlating count per minute field survey readings back to risk, dose, or other ARAR based concentrations. The CPM calculator is a web-based model that estimates a gamma detector response for a given level of contamination. The intent ofmore » the CPM calculator is to facilitate more real-time measurements within a Superfund response framework. The draft of the CPM calculator is still undergoing internal EPA review. This will be followed by external peer review. It is expected that the CPM calculator will at least be in peer review by the time of WM2012 and possibly finalized at that time. The CPM calculator should facilitate greater use of real-time measurement at Superfund sites. The CPM calculator may also standardize the process of converting lab data to real time measurements. It will thus lessen the amount of lab sampling that is needed for site characterization and confirmation surveys, but it will not remove the need for sampling. (authors)« less

  20. Quantitative EEG analysis using error reduction ratio-causality test; validation on simulated and real EEG data.

    PubMed

    Sarrigiannis, Ptolemaios G; Zhao, Yifan; Wei, Hua-Liang; Billings, Stephen A; Fotheringham, Jayne; Hadjivassiliou, Marios

    2014-01-01

    To introduce a new method of quantitative EEG analysis in the time domain, the error reduction ratio (ERR)-causality test. To compare performance against cross-correlation and coherence with phase measures. A simulation example was used as a gold standard to assess the performance of ERR-causality, against cross-correlation and coherence. The methods were then applied to real EEG data. Analysis of both simulated and real EEG data demonstrates that ERR-causality successfully detects dynamically evolving changes between two signals, with very high time resolution, dependent on the sampling rate of the data. Our method can properly detect both linear and non-linear effects, encountered during analysis of focal and generalised seizures. We introduce a new quantitative EEG method of analysis. It detects real time levels of synchronisation in the linear and non-linear domains. It computes directionality of information flow with corresponding time lags. This novel dynamic real time EEG signal analysis unveils hidden neural network interactions with a very high time resolution. These interactions cannot be adequately resolved by the traditional methods of coherence and cross-correlation, which provide limited results in the presence of non-linear effects and lack fidelity for changes appearing over small periods of time. Copyright © 2013 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  1. Real-time micro-vibration multi-spot synchronous measurement within a region based on heterodyne interference

    NASA Astrophysics Data System (ADS)

    Lan, Ma; Xiao, Wen; Chen, Zonghui; Hao, Hongliang; Pan, Feng

    2018-01-01

    Real-time micro-vibration measurement is widely used in engineering applications. It is very difficult for traditional optical detection methods to achieve real-time need in a relatively high frequency and multi-spot synchronous measurement of a region at the same time,especially at the nanoscale. Based on the method of heterodyne interference, an experimental system of real-time measurement of micro - vibration is constructed to satisfy the demand in engineering applications. The vibration response signal is measured by combing optical heterodyne interferometry and a high-speed CMOS-DVR image acquisition system. Then, by extracting and processing multiple pixels at the same time, four digital demodulation technique are implemented to simultaneously acquire the vibrating velocity of the target from the recorded sequences of images. Different kinds of demodulation algorithms are analyzed and the results show that these four demodulation algorithms are suitable for different interference signals. Both autocorrelation algorithm and cross-correlation algorithm meet the needs of real-time measurements. The autocorrelation algorithm demodulates the frequency more accurately, while the cross-correlation algorithm is more accurate in solving the amplitude.

  2. Exploring inter-frame correlation analysis and wavelet-domain modeling for real-time caption detection in streaming video

    NASA Astrophysics Data System (ADS)

    Li, Jia; Tian, Yonghong; Gao, Wen

    2008-01-01

    In recent years, the amount of streaming video has grown rapidly on the Web. Often, retrieving these streaming videos offers the challenge of indexing and analyzing the media in real time because the streams must be treated as effectively infinite in length, thus precluding offline processing. Generally speaking, captions are important semantic clues for video indexing and retrieval. However, existing caption detection methods often have difficulties to make real-time detection for streaming video, and few of them concern on the differentiation of captions from scene texts and scrolling texts. In general, these texts have different roles in streaming video retrieval. To overcome these difficulties, this paper proposes a novel approach which explores the inter-frame correlation analysis and wavelet-domain modeling for real-time caption detection in streaming video. In our approach, the inter-frame correlation information is used to distinguish caption texts from scene texts and scrolling texts. Moreover, wavelet-domain Generalized Gaussian Models (GGMs) are utilized to automatically remove non-text regions from each frame and only keep caption regions for further processing. Experiment results show that our approach is able to offer real-time caption detection with high recall and low false alarm rate, and also can effectively discern caption texts from the other texts even in low resolutions.

  3. Comparison of the Roche COBAS Amplicor Monitor, Roche COBAS Ampliprep/COBAS Taqman and Abbott RealTime Test assays for quantification of hepatitis C virus and HIV RNA.

    PubMed

    Wolff, Dietmar; Gerritzen, Andreas

    2007-01-01

    We have evaluated the performance of two newly developed automated real-time PCR assays, the COBAS Ampliprep/COBAS TaqMan (CAP/CTM) and the Abbott RealTime tests, in the quantification of human immunodeficiency virus (HIV) and hepatitis C virus (HCV) RNA. The widely used semi-automated COBAS Amplicor Monitor (CAM) assay served as the reference test. Several specimens were analyzed, including 102 plasma samples from HCV patients and 109 from HIV patients and 10 samples from negative donors, as well as Quality Control in Molecular Diagnostics (QCMD) and National Institute for Biological Standards and Controls (NIBSC) proficiency program panels. Good correlation was observed among the three assays, with correlation coefficients (R2) of 0.8 (CAM-CAP/CTM), 0.89 (CAM-RealTime) and 0.91 (CAP/CTM-RealTime) for HCV and 0.83 (CAM-RealTime), 0.85 (CAM-CAP/CTM) and 0.89 (CAP/CTM-RealTime) for HIV. The overall concordance for negative/positive results was 100% for HCV and 98% for HIV. All assays were equally able to quantify HCV genotypes 1, 3, 5 and HIV group M (subtypes A-H) and N from QCMD and NIBSC panels. In terms of workflow, the RealTime assay requires more hands-on-time than the CAP/CTM assay. The results indicate that real-time PCR assays can improve the efficiency of end-point PCR tests by better covering viral dynamic ranges and providing higher throughput and automation.

  4. Development of a Software-Defined Radar

    DTIC Science & Technology

    2017-10-01

    waveform to the widest available (unoccupied) instantaneous bandwidth in real time. Consequently, the radar range resolution and target detection are...LabVIEW The matched filter range profile is calculated in real time using fast Fourier transform (FFT) operations to perform a cross-correlation...between the transmitted waveform and the received complex data. Figure 4 demonstrates the block logic used to achieve real -time range profile

  5. Real-time eye lens dose monitoring during cerebral angiography procedures.

    PubMed

    Safari, M J; Wong, J H D; Kadir, K A A; Thorpe, N K; Cutajar, D L; Petasecca, M; Lerch, M L F; Rosenfeld, A B; Ng, K H

    2016-01-01

    To develop a real-time dose-monitoring system to measure the patient's eye lens dose during neuro-interventional procedures. Radiation dose received at left outer canthus (LOC) and left eyelid (LE) were measured using Metal-Oxide-Semiconductor Field-Effect Transistor dosimeters on 35 patients who underwent diagnostic or cerebral embolization procedures. The radiation dose received at the LOC region was significantly higher than the dose received by the LE. The maximum eye lens dose of 1492 mGy was measured at LOC region for an AVM case, followed by 907 mGy for an aneurysm case and 665 mGy for a diagnostic angiography procedure. Strong correlations (shown as R(2)) were observed between kerma-area-product and measured eye doses (LOC: 0.78, LE: 0.68). Lateral and frontal air-kerma showed strong correlations with measured dose at LOC (AKL: 0.93, AKF: 0.78) and a weak correlation with measured dose at LE. A moderate correlation was observed between fluoroscopic time and dose measured at LE and LOC regions. The MOSkin dose-monitoring system represents a new tool enabling real-time monitoring of eye lens dose during neuro-interventional procedures. This system can provide interventionalists with information needed to adjust the clinical procedure to control the patient's dose. Real-time patient dose monitoring helps interventionalists to monitor doses. Strong correlation was observed between kerma-area-product and measured eye doses. Radiation dose at left outer canthus was higher than at left eyelid.

  6. Use of quantitative real-time RT-PCR to investigate the correlation between viremia and viral shedding of canine distemper virus, and infection outcomes in experimentally infected dogs.

    PubMed

    Sehata, Go; Sato, Hiroaki; Ito, Toshihiro; Imaizumi, Yoshitaka; Noro, Taichi; Oishi, Eiji

    2015-07-01

    We used real-time RT-PCR and virus titration to examine canine distemper virus (CDV) kinetics in peripheral blood and rectal and nasal secretions from 12 experimentally infected dogs. Real-time RT-PCR proved extremely sensitive, and the correlation between the two methods for rectal and nasal (r=0.78, 0.80) samples on the peak day of viral RNA was good. Although the dogs showed diverse symptoms, viral RNA kinetics were similar; the peak of viral RNA in the symptomatic dogs was consistent with the onset of symptoms. These results indicate that real-time RT-PCR is sufficiently sensitive to monitor CDV replication in experimentally infected dogs regardless of the degree of clinical manifestation and suggest that the peak of viral RNA reflects active CDV replication.

  7. Use of quantitative real-time RT-PCR to investigate the correlation between viremia and viral shedding of canine distemper virus, and infection outcomes in experimentally infected dogs

    PubMed Central

    SEHATA, Go; SATO, Hiroaki; ITO, Toshihiro; IMAIZUMI, Yoshitaka; NORO, Taichi; OISHI, Eiji

    2015-01-01

    We used real-time RT-PCR and virus titration to examine canine distemper virus (CDV) kinetics in peripheral blood and rectal and nasal secretions from 12 experimentally infected dogs. Real-time RT-PCR proved extremely sensitive, and the correlation between the two methods for rectal and nasal (r=0.78, 0.80) samples on the peak day of viral RNA was good. Although the dogs showed diverse symptoms, viral RNA kinetics were similar; the peak of viral RNA in the symptomatic dogs was consistent with the onset of symptoms. These results indicate that real-time RT-PCR is sufficiently sensitive to monitor CDV replication in experimentally infected dogs regardless of the degree of clinical manifestation and suggest that the peak of viral RNA reflects active CDV replication. PMID:25728411

  8. Comparison between the robo-horse and real horse movements for hippotherapy.

    PubMed

    Park, Ji H; Shurtleff, Timothy; Engsberg, Jack; Rafferty, Sandy; You, Joshua Y; You, Isaac Y; You, Sung H

    2014-01-01

    While the novel robotic hippotherapy system has gradually gained clinical application for therapeutic intervention on postural and locomotor control in individuals with neurological or musculoskeletal impairments, the system's validity and reliability for the robotic hippotherapy system has not been well established. The objective of the current study was to investigate the validity and test-retest reliability of the robotic hippotherapy system by comparing with real horse movements. The 3-axis accelerometer sensors attached on the robotic and real horse saddles were used to collect 3-dimensional acceleration data at a preferred walking velocity. Linear regression analysis showed an excellent correlation in the time-to-peak acceleration (TPA) (R(2)=0.997), but little correlation in X-axis acceleration between the real and robotic horses (R(2)=0.177), thus confirming consistent time control and a certain degree of variability between the robotic and real horse movements. The mean resultant accelerations for a real horse and robotic horse were 3.22 m/s(2) and 0.67 m/s(2), respectively, accounting for almost five times greater acceleration in the real horse than the robotic horse.

  9. Direct modulation of aberrant brain network connectivity through real-time NeuroFeedback.

    PubMed

    Ramot, Michal; Kimmich, Sara; Gonzalez-Castillo, Javier; Roopchansingh, Vinai; Popal, Haroon; White, Emily; Gotts, Stephen J; Martin, Alex

    2017-09-16

    The existence of abnormal connectivity patterns between resting state networks in neuropsychiatric disorders, including Autism Spectrum Disorder (ASD), has been well established. Traditional treatment methods in ASD are limited, and do not address the aberrant network structure. Using real-time fMRI neurofeedback, we directly trained three brain nodes in participants with ASD, in which the aberrant connectivity has been shown to correlate with symptom severity. Desired network connectivity patterns were reinforced in real-time, without participants' awareness of the training taking place. This training regimen produced large, significant long-term changes in correlations at the network level, and whole brain analysis revealed that the greatest changes were focused on the areas being trained. These changes were not found in the control group. Moreover, changes in ASD resting state connectivity following the training were correlated to changes in behavior, suggesting that neurofeedback can be used to directly alter complex, clinically relevant network connectivity patterns.

  10. A real-time extension of density matrix embedding theory for non-equilibrium electron dynamics

    NASA Astrophysics Data System (ADS)

    Kretchmer, Joshua S.; Chan, Garnet Kin-Lic

    2018-02-01

    We introduce real-time density matrix embedding theory (DMET), a dynamical quantum embedding theory for computing non-equilibrium electron dynamics in strongly correlated systems. As in the previously developed static DMET, real-time DMET partitions the system into an impurity corresponding to the region of interest coupled to the surrounding environment, which is efficiently represented by a quantum bath of the same size as the impurity. In this work, we focus on a simplified single-impurity time-dependent formulation as a first step toward a multi-impurity theory. The equations of motion of the coupled impurity and bath embedding problem are derived using the time-dependent variational principle. The accuracy of real-time DMET is compared to that of time-dependent complete active space self-consistent field (TD-CASSCF) theory and time-dependent Hartree-Fock (TDHF) theory for a variety of quantum quenches in the single impurity Anderson model (SIAM), in which the Hamiltonian is suddenly changed (quenched) to induce a non-equilibrium state. Real-time DMET shows a marked improvement over the mean-field TDHF, converging to the exact answer even in the non-trivial Kondo regime of the SIAM. However, as expected from analogous behavior in static DMET, the constrained structure of the real-time DMET wavefunction leads to a slower convergence with respect to active space size, in the single-impurity formulation, relative to TD-CASSCF. Our initial results suggest that real-time DMET provides a promising framework to simulate non-equilibrium electron dynamics in which strong electron correlation plays an important role, and lays the groundwork for future multi-impurity formulations.

  11. A real-time extension of density matrix embedding theory for non-equilibrium electron dynamics.

    PubMed

    Kretchmer, Joshua S; Chan, Garnet Kin-Lic

    2018-02-07

    We introduce real-time density matrix embedding theory (DMET), a dynamical quantum embedding theory for computing non-equilibrium electron dynamics in strongly correlated systems. As in the previously developed static DMET, real-time DMET partitions the system into an impurity corresponding to the region of interest coupled to the surrounding environment, which is efficiently represented by a quantum bath of the same size as the impurity. In this work, we focus on a simplified single-impurity time-dependent formulation as a first step toward a multi-impurity theory. The equations of motion of the coupled impurity and bath embedding problem are derived using the time-dependent variational principle. The accuracy of real-time DMET is compared to that of time-dependent complete active space self-consistent field (TD-CASSCF) theory and time-dependent Hartree-Fock (TDHF) theory for a variety of quantum quenches in the single impurity Anderson model (SIAM), in which the Hamiltonian is suddenly changed (quenched) to induce a non-equilibrium state. Real-time DMET shows a marked improvement over the mean-field TDHF, converging to the exact answer even in the non-trivial Kondo regime of the SIAM. However, as expected from analogous behavior in static DMET, the constrained structure of the real-time DMET wavefunction leads to a slower convergence with respect to active space size, in the single-impurity formulation, relative to TD-CASSCF. Our initial results suggest that real-time DMET provides a promising framework to simulate non-equilibrium electron dynamics in which strong electron correlation plays an important role, and lays the groundwork for future multi-impurity formulations.

  12. Can Subjects be Guided to Optimal Decisions The Use of a Real-Time Training Intervention Model

    DTIC Science & Technology

    2016-06-01

    execution of the task and may then be analyzed to determine if there is correlation between designated factors (scores, proportion of time in each...state with their decision performance in real time could allow training systems to be designed to tailor training to the individual decision maker...release; distribution is unlimited CAN SUBJECTS BE GUIDED TO OPTIMAL DECISIONS? THE USE OF A REAL- TIME TRAINING INTERVENTION MODEL by Travis D

  13. Seeing real-space dynamics of liquid water through inelastic x-ray scattering.

    PubMed

    Iwashita, Takuya; Wu, Bin; Chen, Wei-Ren; Tsutsui, Satoshi; Baron, Alfred Q R; Egami, Takeshi

    2017-12-01

    Water is ubiquitous on earth, but we know little about the real-space motion of molecules in liquid water. We demonstrate that high-resolution inelastic x-ray scattering measurement over a wide range of momentum and energy transfer makes it possible to probe real-space, real-time dynamics of water molecules through the so-called Van Hove function. Water molecules are found to be strongly correlated in space and time with coupling between the first and second nearest-neighbor molecules. The local dynamic correlation of molecules observed here is crucial to a fundamental understanding of the origin of the physical properties of water, including viscosity. The results also suggest that the quantum-mechanical nature of hydrogen bonds could influence its dynamics. The approach used here offers a powerful experimental method for investigating real-space dynamics of liquids.

  14. Real-time three-dimensional color doppler evaluation of the flow convergence zone for quantification of mitral regurgitation: Validation experimental animal study and initial clinical experience

    NASA Technical Reports Server (NTRS)

    Sitges, Marta; Jones, Michael; Shiota, Takahiro; Qin, Jian Xin; Tsujino, Hiroyuki; Bauer, Fabrice; Kim, Yong Jin; Agler, Deborah A.; Cardon, Lisa A.; Zetts, Arthur D.; hide

    2003-01-01

    BACKGROUND: Pitfalls of the flow convergence (FC) method, including 2-dimensional imaging of the 3-dimensional (3D) geometry of the FC surface, can lead to erroneous quantification of mitral regurgitation (MR). This limitation may be mitigated by the use of real-time 3D color Doppler echocardiography (CE). Our objective was to validate a real-time 3D navigation method for MR quantification. METHODS: In 12 sheep with surgically induced chronic MR, 37 different hemodynamic conditions were studied with real-time 3DCE. Using real-time 3D navigation, the radius of the largest hemispherical FC zone was located and measured. MR volume was quantified according to the FC method after observing the shape of FC in 3D space. Aortic and mitral electromagnetic flow probes and meters were balanced against each other to determine reference MR volume. As an initial clinical application study, 22 patients with chronic MR were also studied with this real-time 3DCE-FC method. Left ventricular (LV) outflow tract automated cardiac flow measurement (Toshiba Corp, Tokyo, Japan) and real-time 3D LV stroke volume were used to quantify the reference MR volume (MR volume = 3DLV stroke volume - automated cardiac flow measurement). RESULTS: In the sheep model, a good correlation and agreement was seen between MR volume by real-time 3DCE and electromagnetic (y = 0.77x + 1.48, r = 0.87, P <.001, delta = -0.91 +/- 2.65 mL). In patients, real-time 3DCE-derived MR volume also showed a good correlation and agreement with the reference method (y = 0.89x - 0.38, r = 0.93, P <.001, delta = -4.8 +/- 7.6 mL). CONCLUSIONS: real-time 3DCE can capture the entire FC image, permitting geometrical recognition of the FC zone geometry and reliable MR quantification.

  15. An extension of stochastic hierarchy equations of motion for the equilibrium correlation functions

    NASA Astrophysics Data System (ADS)

    Ke, Yaling; Zhao, Yi

    2017-06-01

    A traditional stochastic hierarchy equations of motion method is extended into the correlated real-time and imaginary-time propagations, in this paper, for its applications in calculating the equilibrium correlation functions. The central idea is based on a combined employment of stochastic unravelling and hierarchical techniques for the temperature-dependent and temperature-free parts of the influence functional, respectively, in the path integral formalism of the open quantum systems coupled to a harmonic bath. The feasibility and validity of the proposed method are justified in the emission spectra of homodimer compared to those obtained through the deterministic hierarchy equations of motion. Besides, it is interesting to find that the complex noises generated from a small portion of real-time and imaginary-time cross terms can be safely dropped to produce the stable and accurate position and flux correlation functions in a broad parameter regime.

  16. Retarded correlators in kinetic theory: branch cuts, poles and hydrodynamic onset transitions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Romatschke, Paul

    In this paper, the collective modes of an effective kinetic theory description based on the Boltzmann equation in a relaxation-time approximation applicable to gauge theories at weak but finite coupling and low frequencies are studied. Real time retarded two-point correlators of the energy-momentum tensor and the R-charge current are calculated at finite temperature in flat space-times for large N gauge theories. It is found that the real-time correlators possess logarithmic branch cuts which in the limit of large coupling disappear and give rise to non-hydrodynamic poles that are reminiscent of quasi-normal modes in black holes. In addition to branch cuts,more » correlators can have simple hydrodynamic poles, generalizing the concept of hydrodynamic modes to intermediate wavelength. Surprisingly, the hydrodynamic poles cease to exist for some critical value of the wavelength and coupling reminiscent of the properties of onset transitions.« less

  17. Retarded correlators in kinetic theory: branch cuts, poles and hydrodynamic onset transitions

    DOE PAGES

    Romatschke, Paul

    2016-06-24

    In this paper, the collective modes of an effective kinetic theory description based on the Boltzmann equation in a relaxation-time approximation applicable to gauge theories at weak but finite coupling and low frequencies are studied. Real time retarded two-point correlators of the energy-momentum tensor and the R-charge current are calculated at finite temperature in flat space-times for large N gauge theories. It is found that the real-time correlators possess logarithmic branch cuts which in the limit of large coupling disappear and give rise to non-hydrodynamic poles that are reminiscent of quasi-normal modes in black holes. In addition to branch cuts,more » correlators can have simple hydrodynamic poles, generalizing the concept of hydrodynamic modes to intermediate wavelength. Surprisingly, the hydrodynamic poles cease to exist for some critical value of the wavelength and coupling reminiscent of the properties of onset transitions.« less

  18. New technique for real-time distortion-invariant multiobject recognition and classification

    NASA Astrophysics Data System (ADS)

    Hong, Rutong; Li, Xiaoshun; Hong, En; Wang, Zuyi; Wei, Hongan

    2001-04-01

    A real-time hybrid distortion-invariant OPR system was established to make 3D multiobject distortion-invariant automatic pattern recognition. Wavelet transform technique was used to make digital preprocessing of the input scene, to depress the noisy background and enhance the recognized object. A three-layer backpropagation artificial neural network was used in correlation signal post-processing to perform multiobject distortion-invariant recognition and classification. The C-80 and NOA real-time processing ability and the multithread programming technology were used to perform high speed parallel multitask processing and speed up the post processing rate to ROIs. The reference filter library was constructed for the distortion version of 3D object model images based on the distortion parameter tolerance measuring as rotation, azimuth and scale. The real-time optical correlation recognition testing of this OPR system demonstrates that using the preprocessing, post- processing, the nonlinear algorithm os optimum filtering, RFL construction technique and the multithread programming technology, a high possibility of recognition and recognition rate ere obtained for the real-time multiobject distortion-invariant OPR system. The recognition reliability and rate was improved greatly. These techniques are very useful to automatic target recognition.

  19. Rapid detection of highly pathogenic porcine reproductive and respiratory syndrome virus by a fluorescent probe-based isothermal recombinase polymerase amplification assay.

    PubMed

    Yang, Yang; Qin, Xiaodong; Sun, Yingjun; Chen, Ting; Zhang, Zhidong

    2016-12-01

    A novel fluorescent probe-based real-time reverse transcription recombinase polymerase amplification (real-time RT-RPA) assay was developed for rapid detection of highly pathogenic type 2 porcine reproductive and respiratory syndrome virus (HP-PRRSV). The sensitivity analysis showed that the detection limit of RPA was 70 copies of HP-PRRSV RNA/reaction. The real-time RT-RPA highly specific amplified HP-PRRSV with no cross-reaction with classic PRRSV, classic swine fever virus, pseudorabies virus, and foot-and-mouth disease virus. Assessment with 125 clinical samples showed that the developed real-time RT-RPA assay was well correlated with real-time RT-qPCR assays for detection of HP-PRRSV. These results suggest that the developed real-time RT-RPA assay is suitable for rapid detection of HP-PRRSV.

  20. Seeing real-space dynamics of liquid water through inelastic x-ray scattering

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Iwashita, Takuya; Wu, Bin; Chen, Wei-Ren

    Water is ubiquitous on earth, but we know little about the real-space motion of molecules in liquid water. We demonstrate that high-resolution inelastic x-ray scattering measurement over a wide range of momentum and energy transfer makes it possible to probe real-space, real-time dynamics of water molecules through the so-called Van Hove function. Water molecules are found to be strongly correlated in space and time with coupling between the first and second nearest-neighbor molecules. The local dynamic correlation of molecules observed here is crucial to a fundamental understanding of the origin of the physical properties of water, including viscosity. The resultsmore » also suggest that the quantum-mechanical nature of hydrogen bonds could influence its dynamics. Finally, the approach used here offers a powerful experimental method for investigating real-space dynamics of liquids.« less

  1. Seeing real-space dynamics of liquid water through inelastic x-ray scattering

    DOE PAGES

    Iwashita, Takuya; Wu, Bin; Chen, Wei-Ren; ...

    2017-12-22

    Water is ubiquitous on earth, but we know little about the real-space motion of molecules in liquid water. We demonstrate that high-resolution inelastic x-ray scattering measurement over a wide range of momentum and energy transfer makes it possible to probe real-space, real-time dynamics of water molecules through the so-called Van Hove function. Water molecules are found to be strongly correlated in space and time with coupling between the first and second nearest-neighbor molecules. The local dynamic correlation of molecules observed here is crucial to a fundamental understanding of the origin of the physical properties of water, including viscosity. The resultsmore » also suggest that the quantum-mechanical nature of hydrogen bonds could influence its dynamics. Finally, the approach used here offers a powerful experimental method for investigating real-space dynamics of liquids.« less

  2. Comparison of Two Commercial Automated Nucleic Acid Extraction and Integrated Quantitation Real-Time PCR Platforms for the Detection of Cytomegalovirus in Plasma

    PubMed Central

    Tsai, Huey-Pin; Tsai, You-Yuan; Lin, I-Ting; Kuo, Pin-Hwa; Chen, Tsai-Yun; Chang, Kung-Chao; Wang, Jen-Ren

    2016-01-01

    Quantitation of cytomegalovirus (CMV) viral load in the transplant patients has become a standard practice for monitoring the response to antiviral therapy. The cut-off values of CMV viral load assays for preemptive therapy are different due to the various assay designs employed. To establish a sensitive and reliable diagnostic assay for preemptive therapy of CMV infection, two commercial automated platforms including m2000sp extraction system integrated the Abbott RealTime (m2000rt) and the Roche COBAS AmpliPrep for extraction integrated COBAS Taqman (CAP/CTM) were evaluated using WHO international CMV standards and 110 plasma specimens from transplant patients. The performance characteristics, correlation, and workflow of the two platforms were investigated. The Abbott RealTime assay correlated well with the Roche CAP/CTM assay (R2 = 0.9379, P<0.01). The Abbott RealTime assay exhibited higher sensitivity for the detection of CMV viral load, and viral load values measured with Abbott RealTime assay were on average 0.76 log10 IU/mL higher than those measured with the Roche CAP/CTM assay (P<0.0001). Workflow analysis on a small batch size at one time, using the Roche CAP/CTM platform had a shorter hands-on time than the Abbott RealTime platform. In conclusion, these two assays can provide reliable data for different purpose in a clinical virology laboratory setting. PMID:27494707

  3. Inertial sensors as real-time feedback improve learning posterior-anterior thoracic manipulation: a randomized controlled trial.

    PubMed

    Cuesta-Vargas, Antonio I; González-Sánchez, Manuel; Lenfant, Yves

    2015-01-01

    The purpose of this study was to analyze the effect of real-time feedback on the learning process for posterior-anterior thoracic manipulation (PATM) comparing 2 undergraduate physiotherapy student groups. The study design was a randomized controlled trial in an educational setting. Sixty-one undergraduate physiotherapy students were divided randomly into 2 groups, G1 (n = 31; group without feedback in real time) and G2 (n = 30; group with real-time feedback) participated in this randomized controlled trial. Two groups of physiotherapy students learned PATM, one using a traditional method and the other using real-time feedback (inertial sensor). Measures were obtained preintervention and postintervention. Intragroup preintervention and postintervention and intergroup postintervention scores were calculated. An analysis of the measures' stability was developed through an interclass correlation index. Time, displacement and velocity, and improvement (only between groups) to reach maximum peak and to reach minimum peak from maximum peak, total manipulation time, and stability of all outcome measures were the outcome measures. Statistically significant differences were found in all variables analyzed (intragroup and intergroup) in favor of G2. The values of interclass correlation ranged from 0.627 to 0.706 (G1) and between 0.881 and 0.997 (G2). This study found that the learning process for PATM is facilitated when the student receives real-time feedback. Copyright © 2015 National University of Health Sciences. Published by Elsevier Inc. All rights reserved.

  4. Direct modulation of aberrant brain network connectivity through real-time NeuroFeedback

    PubMed Central

    Kimmich, Sara; Gonzalez-Castillo, Javier; Roopchansingh, Vinai; Popal, Haroon; White, Emily; Gotts, Stephen J; Martin, Alex

    2017-01-01

    The existence of abnormal connectivity patterns between resting state networks in neuropsychiatric disorders, including Autism Spectrum Disorder (ASD), has been well established. Traditional treatment methods in ASD are limited, and do not address the aberrant network structure. Using real-time fMRI neurofeedback, we directly trained three brain nodes in participants with ASD, in which the aberrant connectivity has been shown to correlate with symptom severity. Desired network connectivity patterns were reinforced in real-time, without participants’ awareness of the training taking place. This training regimen produced large, significant long-term changes in correlations at the network level, and whole brain analysis revealed that the greatest changes were focused on the areas being trained. These changes were not found in the control group. Moreover, changes in ASD resting state connectivity following the training were correlated to changes in behavior, suggesting that neurofeedback can be used to directly alter complex, clinically relevant network connectivity patterns. PMID:28917059

  5. Nonlinear Analysis on Cross-Correlation of Financial Time Series by Continuum Percolation System

    NASA Astrophysics Data System (ADS)

    Niu, Hongli; Wang, Jun

    We establish a financial price process by continuum percolation system, in which we attribute price fluctuations to the investors’ attitudes towards the financial market, and consider the clusters in continuum percolation as the investors share the same investment opinion. We investigate the cross-correlations in two return time series, and analyze the multifractal behaviors in this relationship. Further, we study the corresponding behaviors for the real stock indexes of SSE and HSI as well as the liquid stocks pair of SPD and PAB by comparison. To quantify the multifractality in cross-correlation relationship, we employ multifractal detrended cross-correlation analysis method to perform an empirical research for the simulation data and the real markets data.

  6. Real-time MST radar signal processing using a microcomputer running under FORTH

    NASA Technical Reports Server (NTRS)

    Bowhill, S. A.

    1983-01-01

    Data on power, correlation time, and velocity were obtained at the Urbana radar using microcomputer and a single floppy disk drive. This system includes the following features: (1) measurement of the real and imaginary components of the received signal at 20 altitudes spaced by 1.5 km; (2) coherent integration of these components over a 1/8-s time period; (3) continuous real time display of the height profiles of the two coherently integrated components; (4) real time calculation of the 1 minute averages of the power and autocovariance function up to 6 lags; (5) output of these data to floppy disk once every 2 minutes; (6) display of the 1 minute power profiles while the data are stored to the disk; (7) visual prompting for the operator to change disks when required at the end of each hour of data; and (8) continuous audible indication of the status of the interrupt service routine. Accomplishments were enabled by two developments: the use of a new correlation algorithm and the use of the FORTH language to manage the various low level and high level procedures involved.

  7. One year of real-time radon monitoring at Stromboli volcano and the effect of environmental parameters on 222Rn concentrations

    NASA Astrophysics Data System (ADS)

    Cigolini, C.; Laiolo, M.; Coppola, D.; Piscopo, D.; Bertolino, S.

    2009-12-01

    Real-time radon monitoring at Stromboli volcano has been operative within the last two years. In this contribution we will discuss the recent one-year-long time series analyses in the light of environmental parameters. Two sites for real-time monitoring have been identified by means of a network of periodic radon surveys in order to locate the areas of more efficient response to seismic transients and/or volcanic degassing. Two real-time stations are positioned at Stromboli: one at the summit and located along a fracture zone where the gas flux is concentrated, and the second one at a lower altitude in a sector of diffuse degassing. The signals of the two time-series are essentially concordant but radon concentrations are considerably higher at the summit station. Raw data show that there is a negative correlation between radon emissions and seasonal temperature variations, whereas the correlation with atmospheric pressure is negative for the site of diffuse degassing and sligthly positive for the station lacated along the summit fracture zone. These data and the previously collected ones show that SW winds may substantially decrease radon concentrations at the summit station. Multivarite regression statistics on the radon signals in the light of the above enviromental parameters and tidal forces, may contribute to better idenfify the correlation between radon emissions and variations in volcanic activity. Fig. 1. Radon monitoring stations at Stromboli and the two major summit faults. Stars identify sites for real-time monitoring: LSC and PZZ. The diamond is the location of the automated Labronzo Station. Full dots are stations for periodic measurements using alpha track-etches detectors and E-PERM® electrets. Inset with the location of Stromboli and the major structures of the Aeolian arc.

  8. FY*X real-time polymerase chain reaction with melting curve analysis associated with a complete one-step real-time FY genotyping.

    PubMed

    Ansart-Pirenne, H; Martin-Blanc, S; Le Pennec, P-Y; Rouger, P; Cartron, J-P; Tournamille, C

    2007-02-01

    The Duffy (FY) blood group system is controlled by four major alleles: FY*A and FY*B, the Caucasian common alleles, encoding Fy(a) and Fy(b) antigens; FY*X allele responsible for a poorly expressed Fy(b) antigen, and FY*Fy a silent predominant allele among Black population. Despite the recent development of a real-time fluorescent polymerase chain reaction (PCR) method for FY genotyping FY*X genotyping has not been described by this method. This study focused on the real-time FY*X genotyping development associated with a complete, one-step real-time FY genotyping, based on fluorescence resonance energy transfer (FRET) technology. Seventy-two blood samples from Fy(a+b-) Caucasian blood donors were studied by real-time PCR only. Forty-seven Caucasian and Black individual blood samples, referred to our laboratory, were studied by PCR-RFLP and real-time PCR. For each individual, the result of the genotype was compared to the known phenotype. The FY*X allele frequency calculated in an Fy(a+b-) Caucasian blood donors population was 0.014. With the Caucasian and Black patient samples we found a complete correlation between PCR-RFLP and the real-time PCR method whatever the alleles combination tested. When the known phenotype was not correlated to FY*X genotype, the presence of the Fy(b) antigen was always confirmed by adsorption-elution. The real-time technology method is rapid and accurate for FY genotyping. From now, we are able to detect the FY*X allele in all the alleles combinations studied. Regarding its significant frequency, the detection of the FY*X allele is useful for the correct typing of blood donors and recipients considering the therapeutic use of blood units and the preparation of test red blood cells for antibody screening.

  9. Cooperative multi-user detection and ranging based on pseudo-random codes

    NASA Astrophysics Data System (ADS)

    Morhart, C.; Biebl, E. M.

    2009-05-01

    We present an improved approach for a Round Trip Time of Flight distance measurement system. The system is intended for the usage in a cooperative localisation system for automotive applications. Therefore, it is designed to address a large number of communication partners per measurement cycle. By using coded signals in a time divison multiple access order, we can detect a large number of pedestrian sensors with just one car sensor. We achieve this by using very short transmit bursts in combination with a real time correlation algorithm. Futhermore, the correlation approach offers real time data, concerning the time of arrival, that can serve as a trigger impulse for other comunication systems. The distance accuracy of the correlation result was further increased by adding a fourier interpolation filter. The system performance was checked with a prototype at 2.4 GHz. We reached a distance measurement accuracy of 12 cm at a range up to 450 m.

  10. Commercial counterboard for 10 ns software correlator for photon and fluorescence correlation spectroscopy.

    PubMed

    Molteni, Matteo; Ferri, Fabio

    2016-11-01

    A 10 ns time resolution, multi-tau software correlator, capable of computing simultaneous autocorrelation (A-A, B-B) and cross (A-B) correlation functions at count rates up to ∼10 MHz, with no data loss, has been developed in LabVIEW and C++ by using the National Instrument timer/counterboard (NI PCIe-6612) and a fast Personal Computer (PC) (Intel Core i7-4790 Processor 3.60 GHz ). The correlator works by using two algorithms: for large lag times (τ ≳ 1 μs), a classical time-mode scheme, based on the measure of the number of pulses per time interval, is used; differently, for τ ≲ 1 μs a photon-mode (PM) scheme is adopted and the correlation function is retrieved from the sequence of the photon arrival times. Single auto- and cross-correlation functions can be processed online in full real time up to count rates of ∼1.8 MHz and ∼1.2 MHz, respectively. Two autocorrelation (A-A, B-B) and a cross correlation (A-B) functions can be simultaneously processed in full real time only up to count rates of ∼750 kHz. At higher count rates, the online processing takes place in a delayed modality, but with no data loss. When tested with simulated correlation data and latex spheres solutions, the overall performances of the correlator appear to be comparable with those of commercial hardware correlators, but with several nontrivial advantages related to its flexibility, low cost, and easy adaptability to future developments of PC and data acquisition technology.

  11. Commercial counterboard for 10 ns software correlator for photon and fluorescence correlation spectroscopy

    NASA Astrophysics Data System (ADS)

    Molteni, Matteo; Ferri, Fabio

    2016-11-01

    A 10 ns time resolution, multi-tau software correlator, capable of computing simultaneous autocorrelation (A-A, B-B) and cross (A-B) correlation functions at count rates up to ˜10 MHz, with no data loss, has been developed in LabVIEW and C++ by using the National Instrument timer/counterboard (NI PCIe-6612) and a fast Personal Computer (PC) (Intel Core i7-4790 Processor 3.60 GHz ). The correlator works by using two algorithms: for large lag times (τ ≳ 1 μs), a classical time-mode scheme, based on the measure of the number of pulses per time interval, is used; differently, for τ ≲ 1 μs a photon-mode (PM) scheme is adopted and the correlation function is retrieved from the sequence of the photon arrival times. Single auto- and cross-correlation functions can be processed online in full real time up to count rates of ˜1.8 MHz and ˜1.2 MHz, respectively. Two autocorrelation (A-A, B-B) and a cross correlation (A-B) functions can be simultaneously processed in full real time only up to count rates of ˜750 kHz. At higher count rates, the online processing takes place in a delayed modality, but with no data loss. When tested with simulated correlation data and latex spheres solutions, the overall performances of the correlator appear to be comparable with those of commercial hardware correlators, but with several nontrivial advantages related to its flexibility, low cost, and easy adaptability to future developments of PC and data acquisition technology.

  12. Optimized effective potential in real time: Problems and prospects in time-dependent density-functional theory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mundt, Michael; Kuemmel, Stephan

    2006-08-15

    The integral equation for the time-dependent optimized effective potential (TDOEP) in time-dependent density-functional theory is transformed into a set of partial-differential equations. These equations only involve occupied Kohn-Sham orbitals and orbital shifts resulting from the difference between the exchange-correlation potential and the orbital-dependent potential. Due to the success of an analog scheme in the static case, a scheme that propagates orbitals and orbital shifts in real time is a natural candidate for an exact solution of the TDOEP equation. We investigate the numerical stability of such a scheme. An approximation beyond the Krieger-Li-Iafrate approximation for the time-dependent exchange-correlation potential ismore » analyzed.« less

  13. Real-time high-velocity resolution color Doppler OCT

    NASA Astrophysics Data System (ADS)

    Westphal, Volker; Yazdanfar, Siavash; Rollins, Andrew M.; Izatt, Joseph A.

    2001-05-01

    Color Doppler optical coherence tomography (CDOCT), also called Optical Doppler Tomography) is a noninvasive optical imaging technique, which allows for micron-scale physiological flow mapping simultaneous with morphological OCT imaging. Current systems for real-time endoscopic optical coherence tomography (EOCT) would be enhanced by the capability to visualize sub-surface blood flow for applications in early cancer diagnosis and the management of bleeding ulcers. Unfortunately, previous implementations of CDOCT have either been sufficiently computationally expensive (employing Fourier or Hilbert transform techniques) to rule out real-time imaging of flow, or have been restricted to imaging of excessively high flow velocities when used in real time. We have developed a novel Doppler OCT signal-processing strategy capable of imaging physiological flow rates in real time. This strategy employs cross-correlation processing of sequential A-scans in an EOCT image, as opposed to autocorrelation processing as described previously. To measure Doppler shifts in the kHz range using this technique, it was necessary to stabilize the EOCT interferometer center frequency, eliminate parasitic phase noise, and to construct a digital cross correlation unit able to correlate signals of megahertz bandwidth by a fixed lag of up to a few ms. The performance of the color Doppler OCT system was demonstrated in a flow phantom, demonstrating a minimum detectable flow velocity of ~0.8 mm/s at a data acquisition rate of 8 images/second (with 480 A-scans/image) using a handheld probe. Dynamic flow as well as using it freehanded was shown. Flow was also detectable in a phantom in combination with a clinical usable endoscopic probe.

  14. A Lagrangian Subgridscale Model for Particle Transport Improvement and Application in the Adriatic Sea Using the Navy Coastal Ocean Model

    DTIC Science & Technology

    2006-12-01

    based on input statistical parameters , such as the turbulent velocity fluc- tuation and correlation time scale, without the need of an underlying...8217mVr) 2 + (ar, r- ;m Vm) 2 (8) Tr + Tm which is zero if the model and real parameters coincide. The correlation coefficient rmc between the...well correlated with the latter. The parameters estimated from the corrected velocity, Real(top), Model(mid), Corrected(bottom), Tm=1.5, Gm=l 0, Tr

  15. Real-time edge-enhanced optical correlator

    NASA Technical Reports Server (NTRS)

    Liu, Tsuen-Hsi (Inventor); Cheng, Li-Jen (Inventor)

    1992-01-01

    Edge enhancement of an input image by four-wave mixing a first write beam with a second write beam in a photorefractive crystal, GaAs, was achieved for VanderLugt optical correlation with an edge enhanced reference image by optimizing the power ratio of a second write beam to the first write beam (70:1) and optimizing the power ratio of a read beam, which carries the reference image to the first write beam (100:701). Liquid crystal TV panels are employed as spatial light modulators to change the input and reference images in real time.

  16. A real-time method for autonomous passive acoustic detection-classification of humpback whales.

    PubMed

    Abbot, Ted A; Premus, Vincent E; Abbot, Philip A

    2010-05-01

    This paper describes a method for real-time, autonomous, joint detection-classification of humpback whale vocalizations. The approach adapts the spectrogram correlation method used by Mellinger and Clark [J. Acoust. Soc. Am. 107, 3518-3529 (2000)] for bowhead whale endnote detection to the humpback whale problem. The objective is the implementation of a system to determine the presence or absence of humpback whales with passive acoustic methods and to perform this classification with low false alarm rate in real time. Multiple correlation kernels are used due to the diversity of humpback song. The approach also takes advantage of the fact that humpbacks tend to vocalize repeatedly for extended periods of time, and identification is declared only when multiple song units are detected within a fixed time interval. Humpback whale vocalizations from Alaska, Hawaii, and Stellwagen Bank were used to train the algorithm. It was then tested on independent data obtained off Kaena Point, Hawaii in February and March of 2009. Results show that the algorithm successfully classified humpback whales autonomously in real time, with a measured probability of correct classification in excess of 74% and a measured probability of false alarm below 1%.

  17. Evaluation of a real-time PCR assay for malaria diagnosis in patients from Vietnam and in returned travellers.

    PubMed

    Vo, Thi Kim Duy; Bigot, Patricia; Gazin, Pierre; Sinou, Veronique; De Pina, Jean Jacques; Huynh, Dinh Chien; Fumoux, Francis; Parzy, Daniel

    2007-05-01

    Real-time PCR diagnosis of malaria has advantages over traditional microscopic methods, especially when parasitaemia is low and when dealing with mixed infections. We have developed a new real-time PCR with specific genes in each Plasmodium species present only in one copy to identify the four pathogenic Plasmodium spp. for humans. The sensitivity was less than 25 parasites/microl. No cross-hybridisation was observed with human DNA or among the four Plasmodium spp. Using LightCycler PCR and conventional microscopy, we compared the diagnosis of malaria in patients from Vietnam and in returned European travellers with suspicion of malaria. In patients from Vietnam with suspicion of malaria, one mixed infection was observed by PCR only; the remaining data (54 of 55 patients) correlated with microscopy. In 79 patients without symptoms, low parasitaemia was detected in 7 samples by microscopy and in 16 samples by PCR. In returned travellers, PCR results were correlated with microscopy for all four species in 48 of 56 samples. The eight discrepant results were resolved in favour of real-time PCR diagnosis. This new real-time PCR is a rapid, accurate and efficient method for malaria diagnosis in returned travellers as well as for epidemiological studies or antimalarial efficiency trials in the field.

  18. Trends in Correlation-Based Pattern Recognition and Tracking in Forward-Looking Infrared Imagery

    PubMed Central

    Alam, Mohammad S.; Bhuiyan, Sharif M. A.

    2014-01-01

    In this paper, we review the recent trends and advancements on correlation-based pattern recognition and tracking in forward-looking infrared (FLIR) imagery. In particular, we discuss matched filter-based correlation techniques for target detection and tracking which are widely used for various real time applications. We analyze and present test results involving recently reported matched filters such as the maximum average correlation height (MACH) filter and its variants, and distance classifier correlation filter (DCCF) and its variants. Test results are presented for both single/multiple target detection and tracking using various real-life FLIR image sequences. PMID:25061840

  19. Introduction to Econophysics

    NASA Astrophysics Data System (ADS)

    Mantegna, Rosario N.; Stanley, H. Eugene

    2007-08-01

    Preface; 1. Introduction; 2. Efficient market hypothesis; 3. Random walk; 4. Lévy stochastic processes and limit theorems; 5. Scales in financial data; 6. Stationarity and time correlation; 7. Time correlation in financial time series; 8. Stochastic models of price dynamics; 9. Scaling and its breakdown; 10. ARCH and GARCH processes; 11. Financial markets and turbulence; 12. Correlation and anti-correlation between stocks; 13. Taxonomy of a stock portfolio; 14. Options in idealized markets; 15. Options in real markets; Appendix A: notation guide; Appendix B: martingales; References; Index.

  20. Electro-optical processing of phased array data

    NASA Technical Reports Server (NTRS)

    Casasent, D.

    1973-01-01

    An on-line spatial light modulator for application as the input transducer for a real-time optical data processing system is described. The use of such a device in the analysis and processing of radar data in real time is reported. An interface from the optical processor to a control digital computer was designed, constructed, and tested. The input transducer, optical system, and computer interface have been operated in real time with real time radar data with the input data returns recorded on the input crystal, processed by the optical system, and the output plane pattern digitized, thresholded, and outputted to a display and storage in the computer memory. The correlation of theoretical and experimental results is discussed.

  1. Quantitative microbiological study of human carious dentine by culture and real-time PCR: association of anaerobes with histopathological changes in chronic pulpitis.

    PubMed

    Martin, F Elizabeth; Nadkarni, Mangala A; Jacques, Nicholas A; Hunter, Neil

    2002-05-01

    The bacteria found in carious dentine were correlated with the tissue response of the dental pulps of 65 teeth extracted from patients with advanced caries and pulpitis. Standardized homogenates of carious dentine were plated onto selective and nonselective media under anaerobic and microaerophilic conditions. In addition, real-time PCR was used to quantify the recovery of anaerobic bacteria. Primers and fluorogenic probes were designed to detect the total anaerobic microbial load, the genera Prevotella and Fusobacterium, and the species Prevotella melaninogenica, Porphyromonas endodontalis, Porphyromonas gingivalis, and Micromonas (formerly Peptostreptococcus) micros. The pulpal pathology was categorized according to the cellular response and degenerative changes. Analysis of cultured bacteria showed a predominance of gram-positive microorganisms, particularly lactobacilli. Gram-negative bacteria were also present in significant numbers with Prevotella spp., the most numerous anaerobic group cultured. Real-time PCR analysis indicated a greater microbial load than that determined by colony counting. The total number of anaerobes detected was 41-fold greater by real-time PCR than by colony counting, while the numbers of Prevotella and Fusobacterium spp. detected were 82- and 2.4-fold greater by real-time PCR than by colony counting, respectively. Real-time PCR also identified M. micros, P. endodontalis, and P. gingivalis in 71, 60, and 52% of carious samples, respectively. Correlation matrices of the real-time PCR data revealed significant positive associations between M. micros and P. endodontalis detection and inflammatory degeneration of pulpal tissues. These anaerobes have been strongly implicated in endodontic infections that occur as sequelae to carious pulpitis. Accordingly, the data suggest that the presence of high levels of these bacteria in carious lesions may be indicative of irreversible pulpal pathology.

  2. A self optimizing synthetic organic reactor system using real-time in-line NMR spectroscopy.

    PubMed

    Sans, Victor; Porwol, Luzian; Dragone, Vincenza; Cronin, Leroy

    2015-02-01

    A configurable platform for synthetic chemistry incorporating an in-line benchtop NMR that is capable of monitoring and controlling organic reactions in real-time is presented. The platform is controlled via a modular LabView software control system for the hardware, NMR, data analysis and feedback optimization. Using this platform we report the real-time advanced structural characterization of reaction mixtures, including 19 F, 13 C, DEPT, 2D NMR spectroscopy (COSY, HSQC and 19 F-COSY) for the first time. Finally, the potential of this technique is demonstrated through the optimization of a catalytic organic reaction in real-time, showing its applicability to self-optimizing systems using criteria such as stereoselectivity, multi-nuclear measurements or 2D correlations.

  3. Robust real-time cell analysis method for determining viral infectious titers during development of a viral vaccine production process.

    PubMed

    Charretier, Cédric; Saulnier, Aure; Benair, Loïc; Armanet, Corinne; Bassard, Isabelle; Daulon, Sandra; Bernigaud, Bertrand; Rodrigues de Sousa, Emanuel; Gonthier, Clémence; Zorn, Edouard; Vetter, Emmanuelle; Saintpierre, Claire; Riou, Patrice; Gaillac, David

    2018-02-01

    The classical cell-culture methods, such as cell culture infectious dose 50% (CCID 50 ) assays, are time-consuming, end-point assays currently used during the development of a viral vaccine production process to measure viral infectious titers. However, they are not suitable for handling the large number of tests required for high-throughput and large-scale screening analyses. Impedance-based bio-sensing techniques used in real-time cell analysis (RTCA) to assess cell layer biological status in vitro, provide real-time data. In this proof-of-concept study, we assessed the correlation between the results from CCID 50 and RTCA assays and compared time and costs using monovalent and tetravalent chimeric yellow fever dengue (CYD) vaccine strains. For the RTCA assay, Vero cells were infected with the CYD sample and real-time impedance was recorded, using the dimensionless cell index (CI). The CI peaked just after infection and decreased as the viral cytopathic effect occurred in a dose-dependent manner. The time to the median CI (CIT med ) was correlated with viral titers determined by CCID 50 over a range of about 4-5log 10 CCID 50 /ml. This in-house RTCA virus-titration assay was shown to be a robust method for determining real-time viral infectious titers, and could be an alternative to the classical CCID 50 assay during the development of viral vaccine production process. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  4. Real time observation and automated measurement of red blood cells agglutination inside a passive microfluidic biochip containing embedded reagents.

    PubMed

    Huet, Maxime; Cubizolles, Myriam; Buhot, Arnaud

    2017-07-15

    The process of agglutination is commonly used for the detection of biomarkers like proteins or viruses. The multiple bindings between micrometer sized particles, either latex beads or red blood cells (RBCs), create aggregates that are easily detectable and give qualitative information about the presence of the biomarkers. In most cases, the detection is made by simple naked-eye observation of agglutinates without any access to the kinetics of agglutination. In this study, we address the development of a real-time time observation of RBCs agglutination. Using ABO blood typing as a proof-of-concept, we developed i) an integrated biological protocol suitable for further use as point-of-care (POC) analysis and ii) two dedicated image processing algorithms for the real-time and quantitative measurement of agglutination. Anti-A or anti-B typing reagents were dried inside the microchannel of a passive microfluidic chip designed to enhance capillary flow. A blood drop deposit at the tip of the biochip established a simple biological protocol. In situ agglutination of autologous RBCs was achieved by means of embedded reagents and real time agglutination process was monitored by video recording. Using a training set of 24 experiments, two real-time indicators based on correlation and variance of gray levels were optimized and then further confirmed on a validation set. 100% correct discrimination between positive and negative agglutinations was performed within less than 2min by measuring real-time evolution of both correlation and variance indicators. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. High speed optical object recognition processor with massive holographic memory

    NASA Technical Reports Server (NTRS)

    Chao, T.; Zhou, H.; Reyes, G.

    2002-01-01

    Real-time object recognition using a compact grayscale optical correlator will be introduced. A holographic memory module for storing a large bank of optimum correlation filters, to accommodate the large data throughput rate needed for many real-world applications, has also been developed. System architecture of the optical processor and the holographic memory will be presented. Application examples of this object recognition technology will also be demonstrated.

  6. Clustering of time-course gene expression profiles using normal mixture models with autoregressive random effects

    PubMed Central

    2012-01-01

    Background Time-course gene expression data such as yeast cell cycle data may be periodically expressed. To cluster such data, currently used Fourier series approximations of periodic gene expressions have been found not to be sufficiently adequate to model the complexity of the time-course data, partly due to their ignoring the dependence between the expression measurements over time and the correlation among gene expression profiles. We further investigate the advantages and limitations of available models in the literature and propose a new mixture model with autoregressive random effects of the first order for the clustering of time-course gene-expression profiles. Some simulations and real examples are given to demonstrate the usefulness of the proposed models. Results We illustrate the applicability of our new model using synthetic and real time-course datasets. We show that our model outperforms existing models to provide more reliable and robust clustering of time-course data. Our model provides superior results when genetic profiles are correlated. It also gives comparable results when the correlation between the gene profiles is weak. In the applications to real time-course data, relevant clusters of coregulated genes are obtained, which are supported by gene-function annotation databases. Conclusions Our new model under our extension of the EMMIX-WIRE procedure is more reliable and robust for clustering time-course data because it adopts a random effects model that allows for the correlation among observations at different time points. It postulates gene-specific random effects with an autocorrelation variance structure that models coregulation within the clusters. The developed R package is flexible in its specification of the random effects through user-input parameters that enables improved modelling and consequent clustering of time-course data. PMID:23151154

  7. Detection of tumor markers in prostate cancer and comparison of sensitivity between real time and nested PCR.

    PubMed

    Matsuoka, Takayuki; Shigemura, Katsumi; Yamamichi, Fukashi; Fujisawa, Masato; Kawabata, Masato; Shirakawa, Toshiro

    2012-06-27

    The objective of this study is to investigate and compare the sensitivity in conventional PCR, quantitative real time PCR, nested PCR and western blots for detection of prostate cancer tumor markers using prostate cancer (PCa) cells. We performed conventional PCR, quantitative real time PCR, nested PCR, and western blots using 5 kinds of PCa cells. Prostate specific antigen (PSA), prostate specific membrane antigen (PSMA), and androgen receptor (AR) were compared for their detection sensitivity by real time PCR and nested PCR. In real time PCR, there was a significant correlation between cell number and the RNA concentration obtained (R(2)=0.9944) for PSA, PSMA, and AR. We found it possible to detect these markers from a single LNCaP cell in both real time and nested PCR. By comparison, nested PCR reached a linear curve in fewer PCR cycles than real time PCR, suggesting that nested PCR may offer PCR results more quickly than real time PCR. In conclusion, nested PCR may offer tumor maker detection in PCa cells more quickly (with fewer PCR cycles) with the same high sensitivity as real time PCR. Further study is necessary to establish and evaluate the best tool for PCa tumor marker detection.

  8. Real-time spatio-temporal coherence estimation for autonomous mode identification and invariance tracking

    NASA Technical Reports Server (NTRS)

    Park, Han G. (Inventor); Zak, Michail (Inventor); James, Mark L. (Inventor); Mackey, Ryan M. E. (Inventor)

    2003-01-01

    A general method of anomaly detection from time-correlated sensor data is disclosed. Multiple time-correlated signals are received. Their cross-signal behavior is compared against a fixed library of invariants. The library is constructed during a training process, which is itself data-driven using the same time-correlated signals. The method is applicable to a broad class of problems and is designed to respond to any departure from normal operation, including faults or events that lie outside the training envelope.

  9. Optical Pattern Recognition With Self-Amplification

    NASA Technical Reports Server (NTRS)

    Liu, Hua-Kuang

    1994-01-01

    In optical pattern recognition system with self-amplification, no reference beam used in addressing mode. Polarization of laser beam and orientation of photorefractive crystal chosen to maximize photorefractive effect. Intensity of recognition signal is orders of magnitude greater than other optical correlators. Apparatus regarded as real-time or quasi-real-time optical pattern recognizer with memory and reprogrammability.

  10. Correlations and risk contagion between mixed assets and mixed-asset portfolio VaR measurements in a dynamic view: An application based on time varying copula models

    NASA Astrophysics Data System (ADS)

    Han, Yingying; Gong, Pu; Zhou, Xiang

    2016-02-01

    In this paper, we apply time varying Gaussian and SJC copula models to study the correlations and risk contagion between mixed assets: financial (stock), real estate and commodity (gold) assets in China firstly. Then we study the dynamic mixed-asset portfolio risk through VaR measurement based on the correlations computed by the time varying copulas. This dynamic VaR-copula measurement analysis has never been used on mixed-asset portfolios. The results show the time varying estimations fit much better than the static models, not only for the correlations and risk contagion based on time varying copulas, but also for the VaR-copula measurement. The time varying VaR-SJC copula models are more accurate than VaR-Gaussian copula models when measuring more risky portfolios with higher confidence levels. The major findings suggest that real estate and gold play a role on portfolio risk diversification and there exist risk contagion and flight to quality between mixed-assets when extreme cases happen, but if we take different mixed-asset portfolio strategies with the varying of time and environment, the portfolio risk will be reduced.

  11. Real-Time Unsteady Loads Measurements Using Hot-Film Sensors

    NASA Technical Reports Server (NTRS)

    Mangalam, Arun S.; Moes, Timothy R.

    2004-01-01

    Several flight-critical aerodynamic problems such as buffet, flutter, stall, and wing rock are strongly affected or caused by abrupt changes in unsteady aerodynamic loads and moments. Advanced sensing and flow diagnostic techniques have made possible simultaneous identification and tracking, in real-time, of the critical surface, viscosity-related aerodynamic phenomena under both steady and unsteady flight conditions. The wind tunnel study reported here correlates surface hot-film measurements of leading edge stagnation point and separation point, with unsteady aerodynamic loads on a NACA 0015 airfoil. Lift predicted from the correlation model matches lift obtained from pressure sensors for an airfoil undergoing harmonic pitchup and pitchdown motions. An analytical model was developed that demonstrates expected stall trends for pitchup and pitchdown motions. This report demonstrates an ability to obtain unsteady aerodynamic loads in real-time, which could lead to advances in air vehicle safety, performance, ride-quality, control, and health management.

  12. Correlation between unstimulated salivary flow, pH and streptococcus mutans, analysed with real time PCR, in caries-free and caries-active children.

    PubMed

    Abbate, G M; Borghi, D; Passi, A; Levrini, L

    2014-03-01

    Evaluate the correlations between unstimulated salivary flow, pH and level of S. mutans, analysed through real time PCR, in caries-free and caries-active children. Thirty healthy children were divided into 2 groups: test group (DMFT/dmft ≥ 3 and at least 1 active caries lesion) and control group (DMFT/dmft=0). Un-stimulated saliva was collected, pH was measured and S. mutans and total bacterial amount were evaluated with real-time PCR analysis. Unstimulated salivary flow in the test group was significantly lower (p = 0.0269) compared to group control. The level of S. mutans was higher in the test group (p = 0.176), and an inverse correlation was recorded between total bacterial amount and un-stimulated salivary flow (p = 0.063). In the control group a positive relationship was found between total bacterial amount and S. mutans (p = 0.045) and an inverse correlation between pH and S. mutans (p = 0.088). A t-test and a linear regression analysis were performed. A higher salivary flow and an increased salivary pH seem to represent protective factors against caries in children, while high levels of S. mutans are correlated with caries active lesions. Caries risk assessment should be performed considering all parameters involved in the development of the disease.

  13. Toward determining melt pool quality metrics via coaxial monitoring in laser powder bed fusion.

    PubMed

    Fisher, Brian A; Lane, Brandon; Yeung, Ho; Beuth, Jack

    2018-01-01

    The current industry trend in metal additive manufacturing is towards greater real time process monitoring capabilities during builds to ensure high quality parts. While the hardware implementations that allow for real time monitoring of the melt pool have advanced significantly, the knowledge required to correlate the generated data to useful metrics of interest are still lacking. This research presents promising results that aim to bridge this knowledge gap by determining a novel means to correlate easily obtainable sensor data (thermal emission) to key melt pool size metrics (e.g., melt pool cross sectional area).

  14. [Measurement of left atrial and ventricular volumes in real-time 3D echocardiography. Validation by nuclear magnetic resonance

    NASA Technical Reports Server (NTRS)

    Bauer, F.; Shiota, T.; Qin, J. X.; White, R. D.; Thomas, J. D.

    2001-01-01

    The measurement of the left ventricular ejection fraction is important for the evaluation of cardiomyopathy and depends on the measurement of left ventricular volumes. There are no existing conventional echocardiographic means of measuring the true left atrial and ventricular volumes without mathematical approximations. The aim of this study was to test anew real time 3-dimensional echocardiographic system of calculating left atrial and ventricular volumes in 40 patients after in vitro validation. The volumes of the left atrium and ventricle acquired from real time 3-D echocardiography in the apical view, were calculated in 7 sections parallel to the surface of the probe and compared with atrial (10 patients) and ventricular (30 patients) volumes calculated by nuclear magnetic resonance with the simpson method and with volumes of water in balloons placed in a cistern. Linear regression analysis showed an excellent correlation between the real volume of water in the balloons and volumes given in real time 3-dimensional echocardiography (y = 0.94x + 5.5, r = 0.99, p < 0.001, D = -10 +/- 4.5 ml). A good correlation was observed between real time 3-dimensional echocardiography and nuclear magnetic resonance for the measurement of left atrial and ventricular volumes (y = 0.95x - 10, r = 0.91, p < 0.001, D = -14.8 +/- 19.5 ml and y = 0.87x + 10, r = 0.98, P < 0.001, D = -8.3 +/- 18.7 ml, respectively. The authors conclude that real time three-dimensional echocardiography allows accurate measurement of left heart volumes underlying the clinical potential of this new 3-D method.

  15. A novel accelerated in vitro release method to evaluate the release of thymopentin from PLGA microspheres.

    PubMed

    Xie, Xiangyang; Li, Zhiping; Zhang, Ling; Chi, Qiang; Yang, Yanfang; Zhang, Hui; Yang, Yang; Mei, Xingguo

    2015-01-01

    A novel accelerated method of good correlations with "real-time" release to evaluate in vitro thymopentin release from poly (D, L-lactide-co-glycolide) (PLGA) microsphere was developed. Thymopentin-loaded microspheres were made from three types of PLGA, and peptide release was studied in various conditions. Incomplete release of peptide (<60%) from microspheres was found in accelerated testing with two typical release media. This problem was circumvented by adding organic solvents to the release media and varying the temperature in the media heating process. Release media containing three kinds of organic solvents at 50 °C were tested, respectively, and hydro-alcoholic solution was selected for further study. After the surfactant concentration (0.06%, W/V) and ethanol concentration (20%, V/V) were fixed, a gradient heating program, consisting of three stages and each stage with a different temperature, was introduced to enhance the correlations between the short- and long-term release. After adjusting the heating time of each stage, a good correlation (R(2) = 9896, formulation 8 K; R(2) = 0.9898, formulation 13 K; R(2) = 0.9886, formulation 28 K) between accelerated and "real-time" release was obtained. By optimizing the conditions as ethanol concentration and temperature gradients, this accelerated method may be appropriate for similar peptide formulations that not well correlate with "real-time" release.

  16. Multiplex Real-Time PCR for Monitoring Heterobasidion annosum Colonization in Norway Spruce Clones That Differ in Disease Resistance

    PubMed Central

    Hietala, Ari M.; Eikenes, Morten; Kvaalen, Harald; Solheim, Halvor; Fossdal, Carl G.

    2003-01-01

    A multiplex real-time PCR assay was developed to monitor the dynamics of the Picea abies-Heterobasidion annosum pathosystem. Tissue cultures and 32-year-old trees with low or high resistance to this pathogen were used as the host material. Probes and primers were based on a laccase gene for the pathogen and a polyubiquitin gene for the host. The real-time PCR procedure was compared to an ergosterol-based quantification method in a tissue culture experiment, and there was a strong correlation (product moment correlation coefficient, 0.908) between the data sets. The multiplex real-time PCR procedure had higher resolution and sensitivity during the early stages of colonization and also could be used to monitor the host. In the tissue culture experiment, host DNA was degraded more rapidly in the clone with low resistance than in the clone with high resistance. In the field experiment, the lesions elicited were not strictly proportional to the area colonized by the pathogen. Fungal colonization was more restricted and localized in the lesion in the clone with high resistance, whereas in the clone with low resistance, the fungus could be detected until the visible end of the lesion. Thus, the real-time PCR assay gives better resolution than does the traditionally used lesion length measurement when screening host clones for resistance. PMID:12902224

  17. Neural population-level memory traces in the mouse hippocampus.

    PubMed

    Chen, Guifen; Wang, L Phillip; Tsien, Joe Z

    2009-12-16

    One of the fundamental goals in neurosciences is to elucidate the formation and retrieval of brain's associative memory traces in real-time. Here, we describe real-time neural ensemble transient dynamics in the mouse hippocampal CA1 region and demonstrate their relationships with behavioral performances during both learning and recall. We employed the classic trace fear conditioning paradigm involving a neutral tone followed by a mild foot-shock 20 seconds later. Our large-scale recording and decoding methods revealed that conditioned tone responses and tone-shock association patterns were not present in CA1 during the first pairing, but emerged quickly after multiple pairings. These encoding patterns showed increased immediate-replay, correlating tightly with increased immediate-freezing during learning. Moreover, during contextual recall, these patterns reappeared in tandem six-to-fourteen times per minute, again correlating tightly with behavioral recall. Upon traced tone recall, while various fear memories were retrieved, the shock traces exhibited a unique recall-peak around the 20-second trace interval, further signifying the memory of time for the expected shock. Therefore, our study has revealed various real-time associative memory traces during learning and recall in CA1, and demonstrates that real-time memory traces can be decoded on a moment-to-moment basis over any single trial.

  18. Multi-Level Pre-Correlation RFI Flagging for Real-Time Implementation on UniBoard

    NASA Astrophysics Data System (ADS)

    Dumez-Viou, Cédric; Weber, Rodolphe; Ravier, Philippe

    2016-03-01

    Because of the denser active use of the spectrum, and because of radio telescopes higher sensitivity, radio frequency interference (RFI) mitigation has become a sensitive topic for current and future radio telescope designs. Even if quite sophisticated approaches have been proposed in the recent years, the majority of RFI mitigation operational procedures are based on post-correlation corrupted data flagging. Moreover, given the huge amount of data delivered by current and next generation radio telescopes, all these RFI detection procedures have to be at least automatic and, if possible, real-time. In this paper, the implementation of a real-time pre-correlation RFI detection and flagging procedure into generic high-performance computing platforms based on field programmable gate arrays (FPGA) is described, simulated and tested. One of these boards, UniBoard, developed under a Joint Research Activity in the RadioNet FP7 European programme is based on eight FPGAs interconnected by a high speed transceiver mesh. It provides up to 4 TMACs with ®Altera Stratix IV FPGA and 160 Gbps data rate for the input data stream. The proposed concept is to continuously monitor the data quality at different stages in the digital preprocessing pipeline between the antennas and the correlator, at the station level and the core level. In this way, the detectors are applied at stages where different time-frequency resolutions can be achieved and where the interference-to-noise ratio (INR) is maximum right before any dilution of RFI characteristics by subsequent channelizations or signal recombinations. The detection decisions could be linked to a RFI statistics database or could be attached to the data for later stage flagging. Considering the high in-out data rate in the pre-correlation stages, only real-time and go-through detectors (i.e. no iterative processing) can be implemented. In this paper, a real-time and adaptive detection scheme is described. An ongoing case study has been set up with the Electronic Multi-Beam Radio Astronomy Concept (EMBRACE) radio telescope facility at Nançay Observatory. The objective is to evaluate the performances of this concept in term of hardware complexity, detection efficiency and additional RFI metadata rate cost. The UniBoard implementation scheme is described.

  19. Optical chaos and hybrid WDM/TDM based large capacity quasi-distributed sensing network with real-time fiber fault monitoring.

    PubMed

    Luo, Yiyang; Xia, Li; Xu, Zhilin; Yu, Can; Sun, Qizhen; Li, Wei; Huang, Di; Liu, Deming

    2015-02-09

    An optical chaos and hybrid wavelength division multiplexing/time division multiplexing (WDM/TDM) based large capacity quasi-distributed sensing network with real-time fiber fault monitoring is proposed. Chirped fiber Bragg grating (CFBG) intensity demodulation is adopted to improve the dynamic range of the measurements. Compared with the traditional sensing interrogation methods in time, radio frequency and optical wavelength domains, the measurand sensing and the precise locating of the proposed sensing network can be simultaneously interrogated by the relative amplitude change (RAC) and the time delay of the correlation peak in the cross-correlation spectrum. Assisted with the WDM/TDM technology, hundreds of sensing units could be potentially multiplexed in the multiple sensing fiber lines. Based on the proof-of-concept experiment for axial strain measurement with three sensing fiber lines, the strain sensitivity up to 0.14% RAC/με and the precise locating of the sensors are achieved. Significantly, real-time fiber fault monitoring in the three sensing fiber lines is also implemented with a spatial resolution of 2.8 cm.

  20. The Effects of Real-Time Interactive Multimedia Teleradiology System

    PubMed Central

    Al-Safadi, Lilac

    2016-01-01

    This study describes the design of a real-time interactive multimedia teleradiology system and assesses how the system is used by referring physicians in point-of-care situations and supports or hinders aspects of physician-radiologist interaction. We developed a real-time multimedia teleradiology management system that automates the transfer of images and radiologists' reports and surveyed physicians to triangulate the findings and to verify the realism and results of the experiment. The web-based survey was delivered to 150 physicians from a range of specialties. The survey was completed by 72% of physicians. Data showed a correlation between rich interactivity, satisfaction, and effectiveness. The results of our experiments suggest that real-time multimedia teleradiology systems are valued by referring physicians and may have the potential for enhancing their practice and improving patient care and highlight the critical role of multimedia technologies to provide real-time multimode interactivity in current medical care. PMID:27294118

  1. High-accuracy and real-time 3D positioning, tracking system for medical imaging applications based on 3D digital image correlation

    NASA Astrophysics Data System (ADS)

    Xue, Yuan; Cheng, Teng; Xu, Xiaohai; Gao, Zeren; Li, Qianqian; Liu, Xiaojing; Wang, Xing; Song, Rui; Ju, Xiangyang; Zhang, Qingchuan

    2017-01-01

    This paper presents a system for positioning markers and tracking the pose of a rigid object with 6 degrees of freedom in real-time using 3D digital image correlation, with two examples for medical imaging applications. Traditional DIC method was improved to meet the requirements of the real-time by simplifying the computations of integral pixel search. Experiments were carried out and the results indicated that the new method improved the computational efficiency by about 4-10 times in comparison with the traditional DIC method. The system was aimed for orthognathic surgery navigation in order to track the maxilla segment after LeFort I osteotomy. Experiments showed noise for the static point was at the level of 10-3 mm and the measurement accuracy was 0.009 mm. The system was demonstrated on skin surface shape evaluation of a hand for finger stretching exercises, which indicated a great potential on tracking muscle and skin movements.

  2. Real-time autocorrelator for fluorescence correlation spectroscopy based on graphical-processor-unit architecture: method, implementation, and comparative studies

    NASA Astrophysics Data System (ADS)

    Laracuente, Nicholas; Grossman, Carl

    2013-03-01

    We developed an algorithm and software to calculate autocorrelation functions from real-time photon-counting data using the fast, parallel capabilities of graphical processor units (GPUs). Recent developments in hardware and software have allowed for general purpose computing with inexpensive GPU hardware. These devices are more suited for emulating hardware autocorrelators than traditional CPU-based software applications by emphasizing parallel throughput over sequential speed. Incoming data are binned in a standard multi-tau scheme with configurable points-per-bin size and are mapped into a GPU memory pattern to reduce time-expensive memory access. Applications include dynamic light scattering (DLS) and fluorescence correlation spectroscopy (FCS) experiments. We ran the software on a 64-core graphics pci card in a 3.2 GHz Intel i5 CPU based computer running Linux. FCS measurements were made on Alexa-546 and Texas Red dyes in a standard buffer (PBS). Software correlations were compared to hardware correlator measurements on the same signals. Supported by HHMI and Swarthmore College

  3. Quantification of the biocontrol agent Trichoderma harzianum with real-time TaqMan PCR and its potential extrapolation to the hyphal biomass.

    PubMed

    López-Mondéjar, Rubén; Antón, Anabel; Raidl, Stefan; Ros, Margarita; Pascual, José Antonio

    2010-04-01

    The species of the genus Trichoderma are used successfully as biocontrol agents against a wide range of phytopathogenic fungi. Among them, Trichoderma harzianum is especially effective. However, to develop more effective fungal biocontrol strategies in organic substrates and soil, tools for monitoring the control agents are required. Real-time PCR is potentially an effective tool for the quantification of fungi in environmental samples. The aim of this study consisted of the development and application of a real-time PCR-based method to the quantification of T. harzianum, and the extrapolation of these data to fungal biomass values. A set of primers and a TaqMan probe for the ITS region of the fungal genome were designed and tested, and amplification was correlated to biomass measurements obtained with optical microscopy and image analysis, of the hyphal length of the mycelium of the colony. A correlation of 0.76 between ITS copies and biomass was obtained. The extrapolation of the quantity of ITS copies, calculated based on real-time PCR data, into quantities of fungal biomass provides potentially a more accurate value of the quantity of soil fungi. Copyright 2009 Elsevier Ltd. All rights reserved.

  4. Real-time PCR for quantification of viable Renibacterium salmoninarum in chum salmon Oncorhynchus keta.

    PubMed

    Suzuki, Kunio; Sakai, D K

    2007-03-13

    Quantification of msa gene mRNA of Renibacterium salmoninarum, the causative agent of bacterial kidney disease (BKD), was investigated using reverse transcription followed by real-time PCR assay on R. salmoninarum in culture, and in experimentally challenged chum salmon Oncorhynchus keta fry kidney tissues (total of 70 samples) after intraperitoneal (i.p.) injection and bath infection. Correlations of msa gene mRNA concentrations with culturable cell concentrations (as colony forming units [CFU]), determined by drop-plate culture method on selective kidney disease medium (SKDM) agar through a 12 wk incubation time, and msa gene DNA concentrations by real-time PCR assay were examined. Furthermore, ovarian fluid samples from wild chum salmon adults with no clinical signs of disease were collected from 8 rivers and from clinically infected kokanee 0. nerka and masu salmon O. masou that were reared in 1 and 2 hatcheries, respectively (total of 414 samples). All samples were examined by nested PCR assay. Then, positive samples were examined by real-time PCR assays for mRNA and DNA; mRNA was detectable at 8 log units (5.0 x 101 to 5.0 x 10(9) copies p11(-1)) with high correlation (R2 = 0.999). The mRNA concentration correlated with CFU in kidney tissue from fish infected by i.p. injection (R2 = 0.924), by bath infection (R2 = 0.502) and in culture (R2 = 0.888). R. salmoninarum was detected and quantified by real-time PCR assay for mRNA in ovarian fluid samples in both subclinically infected chum salmon adults and clinically infected kokanee and masu salmon adults; detection rates ranged from 0 to 44.4% and concentrations ranged from 9.7 x 10(2) to 5.6 x 10(5) copies pl(-1). These results indicate that real-time PCR assay for the mRNA is a rapid, sensitive and reliable method to detect and quantify the viability of R. salmoninarum in kidney and ovarian fluid samples of salmonid fishes with both clinical and subclinical infection of the pathogen.

  5. New digital measurement methods for left ventricular volume using real-time three-dimensional echocardiography: comparison with electromagnetic flow method and magnetic resonance imaging

    NASA Technical Reports Server (NTRS)

    Qin, J. J.; Jones, M.; Shiota, T.; Greenberg, N. L.; Firstenberg, M. S.; Tsujino, H.; Zetts, A. D.; Sun, J. P.; Cardon, L. A.; Odabashian, J. A.; hide

    2000-01-01

    AIM: The aim of this study was to investigate the feasibility and accuracy of using symmetrically rotated apical long axis planes for the determination of left ventricular (LV) volumes with real-time three-dimensional echocardiography (3DE). METHODS AND RESULTS: Real-time 3DE was performed in six sheep during 24 haemodynamic conditions with electromagnetic flow measurements (EM), and in 29 patients with magnetic resonance imaging measurements (MRI). LV volumes were calculated by Simpson's rule with five 3DE methods (i.e. apical biplane, four-plane, six-plane, nine-plane (in which the angle between each long axis plane was 90 degrees, 45 degrees, 30 degrees or 20 degrees, respectively) and standard short axis views (SAX)). Real-time 3DE correlated well with EM for LV stroke volumes in animals (r=0.68-0.95) and with MRI for absolute volumes in patients (r-values=0.93-0.98). However, agreement between MRI and apical nine-plane, six-plane, and SAX methods in patients was better than those with apical four-plane and bi-plane methods (mean difference = -15, -18, -13, vs. -31 and -48 ml for end-diastolic volume, respectively, P<0.05). CONCLUSION: Apically rotated measurement methods of real-time 3DE correlated well with reference standards for calculating LV volumes. Balancing accuracy and required time for these LV volume measurements, the apical six-plane method is recommended for clinical use.

  6. Utilization of real time PCR for the assessment of egg burden in the organs of Schistosoma japonicum experimentally infected mice.

    PubMed

    Dang-Trinh, Minh-Anh; Angeles, Jose Ma M; Moendeg, Kharleezelle J; Macalanda, Adrian Miki C; Higuchi, Luna; Oto, Chiho; Kirinoki, Masashi; Chigusa, Yuichi; Kawazu, Shin-Ichiro

    2018-06-01

    Schistosoma japonicum, causing zoonotic intestinal schistosomiasis, is found in China, the Philippines and parts of Indonesia. Severe disease manifestations are basically due to the deposition of eggs in some vital organs such as the liver, spleen and brain. Traditionally, histopathological microscopic examination of the egg burden was used to evaluate the intensity of infection in the affected organs. However, this technique is laborious, time-consuming and requires trained personnel. In this study, real time PCR targeting the mitochondrial NADH dehydrogenase I gene was used to compare with microscopic examination of tissue sections in evaluating the egg burdens in different affected organs. Livers, spleens and brains of the S. japonicum infected mice after 8 and 18 weeks post-infection (p.i) were harvested and examined. Results showed that there were statistically significant correlations between the egg burden evaluated by tissue section examination, and the Ct values of the real time PCR of livers with heavy egg burden at 8 (r = -0.81) and 18 (r = -0.80) weeks p.i. Furthermore, a correlation (r = -0.56) between the egg burden assessed by the microscopic examination and Ct value of the real time PCR of spleens with moderate egg burden after 18 weeks p.i and not 8 weeks p.i was also observed. Brains with low egg burden showed no schistosome eggs in the microscopic examination, however one sample tested positive by real time PCR. These results suggested that real time PCR is useful in evaluating schistosome egg burden in the organs of the experimentally infected mice model that will give further insights into the pathology of schistosomiasis. Copyright © 2018 Elsevier Inc. All rights reserved.

  7. Comparative evaluation of the performance of the Abbott RealTime HIV-1 assay for measurement of HIV-1 plasma viral load on genetically diverse samples from Greece

    PubMed Central

    2011-01-01

    Background HIV-1 is characterized by increased genetic heterogeneity which tends to hinder the reliability of detection and accuracy of HIV-1 RNA quantitation assays. Methods In this study, the Abbott RealTime HIV-1 (Abbott RealTime) assay was compared to the Roche Cobas TaqMan HIV-1 (Cobas TaqMan) and the Siemens Versant HIV-1 RNA 3.0 (bDNA 3.0) assays, using clinical samples of various viral load levels and subtypes from Greece, where the recent epidemiology of HIV-1 infection has been characterized by increasing genetic diversity and a marked increase in subtype A genetic strains among newly diagnosed infections. Results A high correlation was observed between the quantitative results obtained by the Abbott RealTime and the Cobas TaqMan assays. Viral load values quantified by the Abbott RealTime were on average lower than those obtained by the Cobas TaqMan, with a mean (SD) difference of -0.206 (0.298) log10 copies/ml. The mean differences according to HIV-1 subtypes between the two techniques for samples of subtype A, B, and non-A/non-B were 0.089, -0.262, and -0.298 log10 copies/ml, respectively. Overall, differences were less than 0.5 log10 for 85% of the samples, and >1 log10 in only one subtype B sample. Similarly, Abbott RealTime and bDNA 3.0 assays yielded a very good correlation of quantitative results, whereas viral load values assessed by the Abbott RealTime were on average higher (mean (SD) difference: 0.160 (0.287) log10 copies/ml). The mean differences according to HIV-1 subtypes between the two techniques for subtype A, B and non-A/non-B samples were 0.438, 0.105 and 0.191 log10 copies/ml, respectively. Overall, the majority of samples (86%) differed by less than 0.5 log10, while none of the samples showed a deviation of more than 1.0 log10. Conclusions In an area of changing HIV-1 subtype pattern, the Abbott RealTime assay showed a high correlation and good agreement of results when compared both to the Cobas TaqMan and bDNA 3.0 assays, for all HIV-1 subtypes tested. All three assays could determine viral load from samples of different HIV-1 subtypes adequately. However, assay variation should be taken into account when viral load monitoring of the same individual is assessed by different systems. PMID:21219667

  8. Matching-pursuit/split-operator-Fourier-transform computations of thermal correlation functions.

    PubMed

    Chen, Xin; Wu, Yinghua; Batista, Victor S

    2005-02-08

    A rigorous and practical methodology for evaluating thermal-equilibrium density matrices, finite-temperature time-dependent expectation values, and time-correlation functions is described. The method involves an extension of the matching-pursuit/split-operator-Fourier-transform method to the solution of the Bloch equation via imaginary-time propagation of the density matrix and the evaluation of Heisenberg time-evolution operators through real-time propagation in dynamically adaptive coherent-state representations.

  9. A COMPARATIVE STUDY OF REAL-TIME AND STATIC ULTRASONOGRAPHY DIAGNOSES FOR THE INCIDENTAL DETECTION OF DIFFUSE THYROID DISEASE.

    PubMed

    Kim, Dong Wook

    2015-08-01

    The aim of this study was to compare the diagnostic accuracy of real-time and static ultrasonography (US) for the incidental detection of diffuse thyroid disease (DTD). In 118 consecutive patients, a single radiologist performed real-time US before thyroidectomy. For static US, the same radiologist retrospectively investigated the sonographic findings on a picture-archiving and communication system after 3 months. The diagnostic categories of both real-time and static US diagnoses were determined based on the number of abnormal findings, and the diagnostic indices were calculated by a receiver operating characteristic (ROC) curve analysis using the histopathologic results as the reference standard. Histopathologic results included normal thyroid (n = 77), Hashimoto thyroiditis (n = 11), non-Hashimoto lymphocytic thyroiditis (n = 29), and diffuse hyperplasia (n = 1). Normal thyroid and DTD showed significant differences in echogenicity, echotexture, glandular margin, and vascularity on both real-time and static US. There was a positive correlation between US categories and histopathologic results in both real-time and static US. The highest diagnostic indices were obtained when the cutoff criteria of real-time and static US diagnoses were chosen as indeterminate and suspicious for DTD, respectively. The ROC curve analysis showed that real-time US was superior to static US in diagnostic accuracy. Both real-time and static US may be helpful for the detection of incidental DTD, but real-time US is superior to static US for detecting incidental DTD.

  10. Photonic correlator pattern recognition: Application to autonomous docking

    NASA Technical Reports Server (NTRS)

    Sjolander, Gary W.

    1991-01-01

    Optical correlators for real-time automatic pattern recognition applications have recently become feasible due to advances in high speed devices and filter formulation concepts. The devices are discussed in the context of their use in autonomous docking.

  11. Characterization Of Improved Binary Phase-Only Filters In A Real-Time Coherent Optical Correlation System

    NASA Astrophysics Data System (ADS)

    Flannery, D.; Keller, P.; Cartwright, S.; Loomis, J.

    1987-06-01

    Attractive correlation system performance potential is possible using magneto-optic spatial light modulators (SLM) to implement binary phase-only reference filters at high rates, provided the correlation performance of such reduced-information-content filters is adequate for the application. In the case studied here, the desired filter impulse response is a rectangular shape, which cannot be achieved with the usual binary phase-only filter formulation. The correlation application problem is described and techniques for synthesizing improved filter impulse response are considered. A compromise solution involves the cascading of a fixed amplitude-only weighting mask with the binary phase-only SLM. Based on simulations presented, this approach provides improved impulse responses and good correlation performance, while retaining the critical feature of real-time variations of the size, shape, and orientation of the rectangle by electronic programming of the phase pattern in the SLM. Simulations indicate that, for at least one very challenging input scene clutter situation, these filters provide higher correlation signal-to-noise than does "ideal" correlation, i.e. using a perfect rectangle filter response.

  12. [Comparative analysis of real-time quantitative PCR-Sanger sequencing method and TaqMan probe method for detection of KRAS/BRAF mutation in colorectal carcinomas].

    PubMed

    Zhang, Xun; Wang, Yuehua; Gao, Ning; Wang, Jinfen

    2014-02-01

    To compare the application values of real-time quantitative PCR-Sanger sequencing and TaqMan probe method in the detection of KRAS and BRAF mutations, and to correlate KRAS/BRAF mutations with the clinicopathological characteristics in colorectal carcinomas. Genomic DNA of the tumor cells was extracted from formalin fixed paraffin embedded (FFPE) tissue samples of 344 colorectal carcinomas by microdissection. Real-time quantitative PCR-Sanger sequencing and TaqMan probe method were performed to detect the KRAS/BRAF mutations. The frequency and types of KRAS/BRAF mutations, clinicopathological characteristics and survival time were analyzed. KRAS mutations were detected in 39.8% (137/344) and 38.7% (133/344) of 344 colorectal carcinomas by using real-time quantitative PCR-Sanger sequencing and TaqMan probe method, respectively. BRAF mutation was detected in 4.7% (16/344) and 4.1% (14/344), respectively. There was no significant correlation between the two methods. The frequency of the KRAS mutation in female was higher than that in male (P < 0.05). The frequency of the BRAF mutation in colon was higher than that in rectum. The frequency of the BRAF mutation in stage III-IV cases was higher than that in stageI-II cases. The frequency of the BRAF mutation in signet ring cell carcinoma was higher than that in mucinous carcinoma and nonspecific adenocarcinoma had the lowest mutation rate. The frequency of the BRAF mutation in grade III cases was higher than that in grade II cases (P < 0.05). The overall concordance for the two methods of KRAS/BRAF mutation detection was 98.8% (kappa = 0.976). There was statistic significance between BRAF and KRAS mutations for the survival time of colorectal carcinomas (P = 0.039). There were no statistic significance between BRAF mutation type and BRAF/KRAS wild type (P = 0.058). (1) Compared with real-time quantitative PCR-Sanger sequencing, TaqMan probe method is better with regard to handling time, efficiency, repeatability, cost and equipment. (2) The frequency of the KRAS mutation is correlated with gender. BRAF mutation is correlated with primary tumor site, TNM stage, histological types and histological grades.(3) BRAF gene mutation is an independent prognostic marker for colorectal carcinomas.

  13. [Performance evaluation of Abbott RealTime HBV Quantification Kit for HBV viral load by real-time PCR].

    PubMed

    Kim, Myeong Hee; Cha, Choong Hwan; An, Dongheui; Choi, Sung Eun; Oh, Heung Bum

    2008-04-01

    Hepatitis B virus (HBV) DNA quantification is necessary for starting and monitoring of antiviral therapy in patients with chronic hepatitis B. This study was intended to assess the clinical performance of Abbott RealTime HBV Quantification kit (Abbott Laboratories, USA). The performance was evaluated in terms of precision, linearity, detection sensitivity, cross-reactivity, and carry-over. A correlation with the Real-Q HBV Quantification kit (BioSewoom Inc., Korea) was also examined using serum samples from 64 patients diagnosed with chronic hepatitis B and underwent lamivudine therapy in Asan Medical Center. We verified the trueness of the system by comparing the outputs with the assigned values of the BBI panel (BBI Diagnostics, USA). Within-run and between-run coefficients of variation (CV) were 3.56-4.71% and 3.03-4.98%, respectively. Linearity was manifested ranging from 53 to 10(9)copies/mL and the detection sensitivity was verified to be 51 copies/mL. None of hepatitis C virus showed cross-reactivity. No cross-contamination occurred when negative and positive samples were alternatively placed in a row. It showed a good correlation with the Real-Q HBV (r(2)=0.9609) and the test results for the BBI panel were also well agreed to the assigned values (r(2)=0.9933). The performance of Abbott RealTime HBV Quantification kit was excellent; thus, it should be widely used in starting and monitoring of antiviral therapy in Korean patients with chronic hepatitis B.

  14. Real time SAR processing

    NASA Technical Reports Server (NTRS)

    Premkumar, A. B.; Purviance, J. E.

    1990-01-01

    A simplified model for the SAR imaging problem is presented. The model is based on the geometry of the SAR system. Using this model an expression for the entire phase history of the received SAR signal is formulated. From the phase history, it is shown that the range and the azimuth coordinates for a point target image can be obtained by processing the phase information during the intrapulse and interpulse periods respectively. An architecture for a VLSI implementation for the SAR signal processor is presented which generates images in real time. The architecture uses a small number of chips, a new correlation processor, and an efficient azimuth correlation process.

  15. Ambient measurements of biological aerosol particles near Killarney, Ireland: a comparison between real-time fluorescence and microscopy techniques

    NASA Astrophysics Data System (ADS)

    Healy, D. A.; Huffman, J. A.; O'Connor, D. J.; Pöhlker, C.; Pöschl, U.; Sodeau, J. R.

    2014-08-01

    Primary biological aerosol particles (PBAPs) can contribute significantly to the coarse particle burden in many environments. PBAPs can thus influence climate and precipitation systems as cloud nuclei and can spread disease to humans, animals, and plants. Measurement data and techniques for PBAPs in natural environments at high time- and size resolution are, however, sparse, and so large uncertainties remain in the role that biological particles play in the Earth system. In this study two commercial real-time fluorescence particle sensors and a Sporewatch single-stage particle impactor were operated continuously from 2 August to 2 September 2010 at a rural sampling location in Killarney National Park in southwestern Ireland. A cascade impactor was operated periodically to collect size-resolved particles during exemplary periods. Here we report the first ambient comparison of a waveband integrated bioaerosol sensor (WIBS-4) with a ultraviolet aerodynamic particle sizer (UV-APS) and also compare these real-time fluorescence techniques with results of fluorescence and optical microscopy of impacted samples. Both real-time instruments showed qualitatively similar behavior, with increased fluorescent bioparticle concentrations at night, when relative humidity was highest and temperature was lowest. The fluorescent particle number from the FL3 channel of the WIBS-4 and from the UV-APS were strongly correlated and dominated by a 3 μm mode in the particle size distribution. The WIBS FL2 channel exhibited particle modes at approx. 1 and 3 μm, and each was correlated with the concentration of fungal spores commonly observed in air samples collected at the site (ascospores, basidiospores, Ganoderma spp.). The WIBS FL1 channel exhibited variable multimodal distributions turning into a broad featureless single mode after averaging, and exhibited poor correlation with fungal spore concentrations, which may be due to the detection of bacterial and non-biological fluorescent particles. Cladosporium spp., which are among the most abundant fungal spores in many terrestrial environments, were not correlated with any of the real-time fluorescence channels, suggesting that the real-time fluorescence instruments are relatively insensitive to PBAP classes with dark, highly absorptive cell walls. Fluorescence microscopy images of cascade impactor plates showed large numbers of coarse-mode particles consistent with the morphology and weak fluorescence expected of sea salt. Some of these particles were attached to biological cells, suggesting that a marine source influenced the PBAPs observed at the site and that the ocean may be an important contributor to PBAP loadings in coastal environments.

  16. Ambient measurements of biological aerosol particles near Killarney, Ireland: a comparison between real-time fluorescence and microscopy techniques

    NASA Astrophysics Data System (ADS)

    Healy, D. A.; Huffman, J. A.; O'Connor, D. J.; Pöhlker, C.; Pöschl, U.; Sodeau, J. R.

    2014-02-01

    Primary biological aerosol particles (PBAP) can contribute significantly to the coarse particle burden in many environments, may thus influence climate and precipitation systems as cloud nuclei, and can spread disease to humans, animals, and plants. Measurements of PBAP in natural environments taken at high time- and size- resolution are, however, sparse and so large uncertainties remain in the role that biological particles play in the Earth system. In this study two commercial real-time fluorescence particle sensors and a Sporewatch single-stage particle impactor were operated continuously from 2 August to 2 September 2010 at a rural sampling location in Killarney National Park in south western Ireland. A cascade impactor was operated periodically to collect size-resolved particles during exemplary periods. Here we report the first ambient comparison of the waveband integrated bioaerosol sensor (WIBS-4) with the ultraviolet aerodynamic particle sizer (UV-APS) and also compare these real-time fluorescence techniques with results of fluorescence and optical microscopy of impacted samples. Both real-time instruments showed qualitatively similar behaviour, with increased fluorescent bioparticle concentrations at night when relative humidity was highest and temperature was lowest. The fluorescent particle number from the FL3 channel of the WIBS-4 and from the UV-APS were strongly correlated and dominated by a 3 μm mode in the particle size distribution. The WIBS FL2 channel exhibited particle modes at approx. 1 and 3 μm, and each were correlated with the concentration of fungal spores commonly observed in air samples collected at the site (ascospores, basidiospores, Ganoderma spp.). The WIBS FL1 channel exhibited variable multi-modal distributions turning into a broad featureless single mode after averaging and exhibited poor correlation with fungal spore concentrations, which may be due to the detection of bacterial and non-biological fluorescent particles. Cladosporium spp., which are among the most abundant fungal spores in many terrestrial environments, were not correlated with any of the real-time fluorescence channels, suggesting that the real-time fluorescence instruments are insensitive to PBAP classes with dark, highly absorptive cell walls. Fluorescence microscopy images of cascade impactor plates showed large numbers of coarse mode particles consistent with the morphology and weak fluorescence expected of sea salt. Some of these particles were attached to biological cells, suggesting that a marine source influenced the PBAP observed at the site and that the ocean may be an important contributor to PBAP loadings in coastal environments.

  17. Incidence of pulmonary aspergillosis and correlation of conventional diagnostic methods with nested PCR and real-time PCR assay using BAL fluid in intensive care unit patients.

    PubMed

    Zarrinfar, Hossein; Makimura, Koichi; Satoh, Kazuo; Khodadadi, Hossein; Mirhendi, Hossein

    2013-05-01

    Although the incidence of invasive aspergillosis in the intensive care unit (ICU) is scarce, it has emerged as major problems in critically ill patients. In this study, the incidence of pulmonary aspergillosis (PA) in ICU patients has evaluated and direct microscopy and culture has compared with nested polymerase chain reaction (PCR) and real-time PCR for detection of Aspergillus fumigatus and A. flavus in bronchoalveolar lavage (BAL) samples of the patients. Thirty BAL samples obtained from ICU patients during a 16-month period were subjected to direct examinations on 20% potassium hydroxide (KOH) and culture on two culture media. Nested PCR targeting internal transcribed spacer ribosomal DNA and TaqMan real-time PCR assay targeting β-tubulin gene were used for the detection of A. fumigatus and A. flavus. Of 30 patients, 60% were men and 40% were women. The diagnosis of invasive PA was probable in 1 (3%), possible in 11 (37%), and not IPA in 18 (60%). Nine samples were positive in nested PCR including seven samples by A. flavus and two by A. fumigatus specific primers. The lowest amount of DNA that TaqMan real-time PCR could detect was ≥40 copy numbers. Only one of the samples had a positive result of A. flavus real-time PCR with Ct value of 37.5. Although a significant number of specimens were positive in nested PCR, results of this study showed that establishment of a correlation between the conventional methods with nested PCR and real-time PCR needs more data confirmed by a prospective study with a larger sample group. © 2013 Wiley Periodicals, Inc.

  18. Asymptotic coincidence of the statistics for degenerate and non-degenerate correlated real Wishart ensembles

    NASA Astrophysics Data System (ADS)

    Wirtz, Tim; Kieburg, Mario; Guhr, Thomas

    2017-06-01

    The correlated Wishart model provides the standard benchmark when analyzing time series of any kind. Unfortunately, the real case, which is the most relevant one in applications, poses serious challenges for analytical calculations. Often these challenges are due to square root singularities which cannot be handled using common random matrix techniques. We present a new way to tackle this issue. Using supersymmetry, we carry out an anlaytical study which we support by numerical simulations. For large but finite matrix dimensions, we show that statistical properties of the fully correlated real Wishart model generically approach those of a correlated real Wishart model with doubled matrix dimensions and doubly degenerate empirical eigenvalues. This holds for the local and global spectral statistics. With Monte Carlo simulations we show that this is even approximately true for small matrix dimensions. We explicitly investigate the k-point correlation function as well as the distribution of the largest eigenvalue for which we find a surprisingly compact formula in the doubly degenerate case. Moreover we show that on the local scale the k-point correlation function exhibits the sine and the Airy kernel in the bulk and at the soft edges, respectively. We also address the positions and the fluctuations of the possible outliers in the data.

  19. Real-time Fatigue and Free-Living Physical Activity in Hematopoietic Stem Cell Transplantation Cancer Survivors and Healthy Controls: A Preliminary Examination of the Temporal, Dynamic Relationship.

    PubMed

    Hacker, Eileen Danaher; Kim, Inah; Park, Chang; Peters, Tara

    Fatigue and physical inactivity, critical problems facing cancer survivors, impact overall health and functioning. Our group designed a novel methodology to evaluate the temporal, dynamic patterns in real-world settings. Using real-time technology, the temporal, dynamic relationship between real-time fatigue and free-living is described and compared in cancer survivors who were treated with hematopoietic stem cell transplantation (n = 25) and age- and gender-matched healthy controls (n = 25). Subjects wore wrist actigraphs on their nondominant hand to assess free-living physical activity, measured in 1-minute epochs, over 7 days. Subjects entered real-time fatigue assessments directly into the subjective event marker of the actigraph 5 times per day. Running averages of mean 1-minute activity counts 30, 60, and 120 minutes before and after each real-time fatigue score were correlated with real-time fatigue using generalized estimating equations, RESULTS:: A strong inverse relationship exists between real-time fatigue and subsequent free-living physical activity. This inverse relationship suggests that increasing real-time fatigue limits subsequent physical activity (B range= -0.002 to -0.004; P < .001). No significant differences in the dynamic patterns of real-time fatigue and free-living physical activity were found between groups. To our knowledge, this is the first study to document the temporal and potentially causal relationship between real-time fatigue and free-living physical activity in real-world setting. These findings suggest that fatigue drives the subsequent physical activity and the relationship may not be bidirectional. Understanding the temporal, dynamic relationship may have important health implications for developing interventions to address fatigue in cancer survivors.

  20. Real-time emergency forecasting technique for situation management systems

    NASA Astrophysics Data System (ADS)

    Kopytov, V. V.; Kharechkin, P. V.; Naumenko, V. V.; Tretyak, R. S.; Tebueva, F. B.

    2018-05-01

    The article describes the real-time emergency forecasting technique that allows increasing accuracy and reliability of forecasting results of any emergency computational model applied for decision making in situation management systems. Computational models are improved by the Improved Brown’s method applying fractal dimension to forecast short time series data being received from sensors and control systems. Reliability of emergency forecasting results is ensured by the invalid sensed data filtering according to the methods of correlation analysis.

  1. Real-time processing in picture naming in adults who stutter: ERP evidence

    PubMed Central

    Maxfield, Nathan D.; Morris, Kalie; Frisch, Stefan A.; Morphew, Kathryn; Constantine, Joseph L.

    2014-01-01

    Objective The aim was to compare real-time language/cognitive processing in picture naming in adults who stutter (AWS) versus typically-fluent adults (TFA). Methods Participants named pictures preceded by masked prime words. Primes and target picture labels were Identical or mismatched. Priming effects on naming and picture-elicited ERP activity were analyzed. Vocabulary knowledge correlations with these measures were assessed. Results Priming improved naming RTs and accuracy in both groups. RTs were longer for AWS, and correlated positively with receptive vocabulary in TFA. Electrophysiologically, posterior-P1 amplitude negatively correlated with expressive vocabulary in TFA versus receptive vocabulary in AWS. Frontal/temporal-P1 amplitude correlated positively with expressive vocabulary in AWS. Identity priming enhanced frontal/posterior-N2 amplitude in both groups, and attenuated P280 amplitude in AWS. N400 priming was topographically-restricted in AWS. Conclusions Results suggest that conceptual knowledge was perceptually-grounded in expressive vocabulary in TFA versus receptive vocabulary in AWS. Poorer expressive vocabulary in AWS was potentially associated with greater suppression of irrelevant conceptual information. Priming enhanced N2-indexed cognitive control and visual attention in both groups. P280-indexed focal attention attenuated with priming in AWS only. Topographically-restricted N400 priming suggests that lemma/word form connections were weaker in AWS. Significance Real-time language/cognitive processing in picture naming operates differently in AWS. PMID:24910149

  2. Methods of Constructing a Blended Performance Function Suitable for Formation Flight

    NASA Technical Reports Server (NTRS)

    Ryan, John J.

    2017-01-01

    This paper presents two methods for constructing an approximate performance function of a desired parameter using correlated parameters. The methods are useful when real-time measurements of a desired performance function are not available to applications such as extremum-seeking control systems. The first method approximates an a priori measured or estimated desired performance function by combining real-time measurements of readily available correlated parameters. The parameters are combined using a weighting vector determined from a minimum-squares optimization to form a blended performance function. The blended performance function better matches the desired performance function mini- mum than single-measurement performance functions. The second method expands upon the first by replacing the a priori data with near-real-time measurements of the desired performance function. The resulting blended performance function weighting vector is up- dated when measurements of the desired performance function are available. Both methods are applied to data collected during formation- flight-for-drag-reduction flight experiments.

  3. Feature-extracted joint transform correlation.

    PubMed

    Alam, M S

    1995-12-10

    A new technique for real-time optical character recognition that uses a joint transform correlator is proposed. This technique employs feature-extracted patterns for the reference image to detect a wide range of characters in one step. The proposed technique significantly enhances the processing speed when compared with the presently available joint transform correlator architectures and shows feasibility for multichannel joint transform correlation.

  4. Segmentation of time series with long-range fractal correlations.

    PubMed

    Bernaola-Galván, P; Oliver, J L; Hackenberg, M; Coronado, A V; Ivanov, P Ch; Carpena, P

    2012-06-01

    Segmentation is a standard method of data analysis to identify change-points dividing a nonstationary time series into homogeneous segments. However, for long-range fractal correlated series, most of the segmentation techniques detect spurious change-points which are simply due to the heterogeneities induced by the correlations and not to real nonstationarities. To avoid this oversegmentation, we present a segmentation algorithm which takes as a reference for homogeneity, instead of a random i.i.d. series, a correlated series modeled by a fractional noise with the same degree of correlations as the series to be segmented. We apply our algorithm to artificial series with long-range correlations and show that it systematically detects only the change-points produced by real nonstationarities and not those created by the correlations of the signal. Further, we apply the method to the sequence of the long arm of human chromosome 21, which is known to have long-range fractal correlations. We obtain only three segments that clearly correspond to the three regions of different G + C composition revealed by means of a multi-scale wavelet plot. Similar results have been obtained when segmenting all human chromosome sequences, showing the existence of previously unknown huge compositional superstructures in the human genome.

  5. Automated real-time needle-guide tracking for fast 3-T MR-guided transrectal prostate biopsy: a feasibility study.

    PubMed

    Zamecnik, Patrik; Schouten, Martijn G; Krafft, Axel J; Maier, Florian; Schlemmer, Heinz-Peter; Barentsz, Jelle O; Bock, Michael; Fütterer, Jurgen J

    2014-12-01

    To assess the feasibility of automatic needle-guide tracking by using a real-time phase-only cross correlation ( POCC phase-only cross correlation ) algorithm-based sequence for transrectal 3-T in-bore magnetic resonance (MR)-guided prostate biopsies. This study was approved by the ethics review board, and written informed consent was obtained from all patients. Eleven patients with a prostate-specific antigen level of at least 4 ng/mL (4 μg/L) and at least one transrectal ultrasonography-guided biopsy session with negative findings were enrolled. Regions suspicious for cancer were identified on 3-T multiparametric MR images. During a subsequent MR-guided biopsy, the regions suspicious for cancer were reidentified and targeted by using the POCC phase-only cross correlation -based tracking sequence. Besides testing a general technical feasibility of the biopsy procedure by using the POCC phase-only cross correlation -based tracking sequence, the procedure times were measured, and a pathologic analysis of the biopsy cores was performed. Thirty-eight core samples were obtained from 25 regions suspicious for cancer. It was technically feasible to perform the POCC phase-only cross correlation -based biopsies in all regions suspicious for cancer in each patient, with adequate biopsy samples obtained with each biopsy attempt. The median size of the region suspicious for cancer was 8 mm (range, 4-13 mm). In each region suspicious for cancer (median number per patient, two; range, 1-4), a median of one core sample per region was obtained (range, 1-3). The median time for guidance per target was 1.5 minutes (range, 0.7-5 minutes). Nineteen of 38 core biopsy samples contained cancer. This study shows that it is feasible to perform transrectal 3-T MR-guided biopsies by using a POCC phase-only cross correlation algorithm-based real-time tracking sequence. © RSNA, 2014.

  6. Paradoxical results of two automated real-time PCR assays in the diagnosis of pleural tuberculosis.

    PubMed

    Morales-López, Soraya E; Yepes, Jayr A; Anzola, Irina; Aponte, Hernán; Llerena-Polo, Claudia R

    2017-01-01

    Tuberculosis (TB) is a major cause of worldwide mortality. We report the case of a non-HIV-infected woman with clinical suspicion of pleural tuberculosis and contradictory results between Xpert ® MTB/RIF and Abbott RealTime MTB assays from pleural fluid specimen. Liquid and solid cultures for tuberculosis were performed with negative results. The patient received treatment, and clinical improvement was observed. Both techniques detect Mycobacterium tuberculosis complex, but they have different targets and limits of detection. Abbott RealTime MTB results correlated well with the clinical findings of the patient. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  7. Real-time detection of natural objects using AM-coded spectral matching imager

    NASA Astrophysics Data System (ADS)

    Kimachi, Akira

    2004-12-01

    This paper describes application of the amplitude-modulation (AM)-coded spectral matching imager (SMI) to real-time detection of natural objects such as human beings, animals, vegetables, or geological objects or phenomena, which are much more liable to change with time than artificial products while often exhibiting characteristic spectral functions associated with some specific activity states. The AM-SMI produces correlation between spectral functions of the object and a reference at each pixel of the correlation image sensor (CIS) in every frame, based on orthogonal amplitude modulation (AM) of each spectral channel and simultaneous demodulation of all channels on the CIS. This principle makes the SMI suitable to monitoring dynamic behavior of natural objects in real-time by looking at a particular spectral reflectance or transmittance function. A twelve-channel multispectral light source was developed with improved spatial uniformity of spectral irradiance compared to a previous one. Experimental results of spectral matching imaging of human skin and vegetable leaves are demonstrated, as well as a preliminary feasibility test of imaging a reflective object using a test color chart.

  8. Real-time detection of natural objects using AM-coded spectral matching imager

    NASA Astrophysics Data System (ADS)

    Kimachi, Akira

    2005-01-01

    This paper describes application of the amplitude-modulation (AM)-coded spectral matching imager (SMI) to real-time detection of natural objects such as human beings, animals, vegetables, or geological objects or phenomena, which are much more liable to change with time than artificial products while often exhibiting characteristic spectral functions associated with some specific activity states. The AM-SMI produces correlation between spectral functions of the object and a reference at each pixel of the correlation image sensor (CIS) in every frame, based on orthogonal amplitude modulation (AM) of each spectral channel and simultaneous demodulation of all channels on the CIS. This principle makes the SMI suitable to monitoring dynamic behavior of natural objects in real-time by looking at a particular spectral reflectance or transmittance function. A twelve-channel multispectral light source was developed with improved spatial uniformity of spectral irradiance compared to a previous one. Experimental results of spectral matching imaging of human skin and vegetable leaves are demonstrated, as well as a preliminary feasibility test of imaging a reflective object using a test color chart.

  9. Combined Use of a Patient Dose Monitoring System and a Real-Time Occupational Dose Monitoring System for Fluoroscopically Guided Interventions.

    PubMed

    Heilmaier, Christina; Kara, Levent; Zuber, Niklaus; Berthold, Christian; Weishaupt, Dominik

    2016-04-01

    To determine the effect on patient radiation exposure of the combined use of a patient dose monitoring system and real-time occupational dose monitoring during fluoroscopically guided interventions (FGIs). Patient radiation exposure, in terms of the kerma area product (KAP; Gy ∙ cm(2)), was measured in period 1 with a patient dose monitoring system, and a real-time occupational dose monitoring system was additionally applied in period 2. Mean/median KAP in 19 different types of FGIs was analyzed in both periods for two experienced interventional radiologists combined as well as individually. Patient dose and occupational dose were correlated, applying Pearson and Spearman correlation coefficients. Although FGIs were similar in numbers and types over both periods, a substantial decrease was found for period 2 in total mean ± SD/median KAP for both operators together (period 1, 47 Gy ∙ cm(2) ± 67/41 Gy ∙ cm(2); period 2, 37 Gy ∙ cm(2) ± 69/34 Gy ∙ cm(2)) as well as for each individual operator (for all, P < .05). Overall, KAP declined considerably in 15 of 19 types of FGIs in period 2. Mean accumulated dose per intervention was 4.6 µSv, and mean dose rate was 0.24 mSv/h. There was a strong positive correlation between patient and occupational dose (r = 0.88). Combined use of a patient dose monitoring system and a real-time occupational dose monitoring system in FGIs significantly lessens patient and operator doses. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.

  10. Real three-dimensional objects: effects on mental rotation.

    PubMed

    Felix, Michael C; Parker, Joshua D; Lee, Charles; Gabriel, Kara I

    2011-08-01

    The current experiment investigated real three-dimensional (3D) objects with regard to performance on a mental rotation task and whether the appearance of sex differences may be mediated by experiences with spatially related activities. 40 men and 40 women were presented with alternating timed trials consisting of real-3D objects or two-dimensional illustrations of 3D objects. Sex differences in spatially related activities did not significantly influence the finding that men outperformed women on mental rotation of either stimulus type. However, on measures related to spatial activities, self-reported proficiency using maps correlated positively with performance only on trials with illustrations whereas self-reported proficiency using GPS correlated negatively with performance regardless of stimulus dimensionality. Findings may be interpreted as suggesting that rotating real-3D objects utilizes distinct but overlapping spatial skills compared to rotating two-dimensional representations of 3D objects, and real-3D objects can enhance mental rotation performance.

  11. Continuous Rapid Quantification of Stroke Volume Using Magnetohydrodynamic Voltages in 3T Magnetic Resonance Imaging.

    PubMed

    Gregory, T Stan; Oshinski, John; Schmidt, Ehud J; Kwong, Raymond Y; Stevenson, William G; Ho Tse, Zion Tsz

    2015-12-01

    To develop a technique to noninvasively estimate stroke volume in real time during magnetic resonance imaging (MRI)-guided procedures, based on induced magnetohydrodynamic voltages (VMHD) that occur in ECG recordings during MRI exams, leaving the MRI scanner free to perform other imaging tasks. Because of the relationship between blood flow (BF) and VMHD, we hypothesized that a method to obtain stroke volume could be derived from extracted VMHD vectors in the vectorcardiogram (VCG) frame of reference (VMHDVCG). To estimate a subject-specific BF-VMHD model, VMHDVCG was acquired during a 20-s breath-hold and calibrated versus aortic BF measured using phase-contrast magnetic resonance in 10 subjects (n=10) and 1 subject diagnosed with premature ventricular contractions. Beat-to-beat validation of VMHDVCG-derived BF was performed using real-time phase-contrast imaging in 7 healthy subjects (n=7) during 15-minute cardiac exercise stress tests and 30 minutes after stress relaxation in 3T MRIs. Subject-specific equations were derived to correlate VMHDVCG with BF at rest and validated using real-time phase-contrast. An average error of 7.22% and 3.69% in stroke volume estimation, respectively, was found during peak stress and after complete relaxation. Measured beat-to-beat BF time history derived from real-time phase-contrast and VMHD was highly correlated using a Spearman rank correlation coefficient during stress tests (0.89) and after stress relaxation (0.86). Accurate beat-to-beat stroke volume and BF were estimated using VMHDVCG extracted from intra-MRI 12-lead ECGs, providing a means to enhance patient monitoring during MR imaging and MR-guided interventions. © 2015 American Heart Association, Inc.

  12. Estimation and enhancement of real-time software reliability through mutation analysis

    NASA Technical Reports Server (NTRS)

    Geist, Robert; Offutt, A. J.; Harris, Frederick C., Jr.

    1992-01-01

    A simulation-based technique for obtaining numerical estimates of the reliability of N-version, real-time software is presented. An extended stochastic Petri net is employed to represent the synchronization structure of N versions of the software, where dependencies among versions are modeled through correlated sampling of module execution times. Test results utilizing specifications for NASA's planetary lander control software indicate that mutation-based testing could hold greater potential for enhancing reliability than the desirable but perhaps unachievable goal of independence among N versions.

  13. Correlations and clustering in wholesale electricity markets

    DOE PAGES

    Cui, Tianyu; Caravelli, Francesco; Ududec, Cozmin

    2017-11-24

    We study the structure of locational marginal prices in day-ahead and real-time wholesale electricity markets. In particular, we consider the case of two North American markets and show that the price correlations contain information on the locational structure of the grid. We study various clustering methods and introduce a type of correlation function based on event synchronization for spiky time series, and another based on string correlations of location names provided by the markets. As a result, this allows us to reconstruct aspects of the locational structure of the grid.

  14. Correlations and clustering in wholesale electricity markets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cui, Tianyu; Caravelli, Francesco; Ududec, Cozmin

    We study the structure of locational marginal prices in day-ahead and real-time wholesale electricity markets. In particular, we consider the case of two North American markets and show that the price correlations contain information on the locational structure of the grid. We study various clustering methods and introduce a type of correlation function based on event synchronization for spiky time series, and another based on string correlations of location names provided by the markets. As a result, this allows us to reconstruct aspects of the locational structure of the grid.

  15. Correlations and clustering in wholesale electricity markets

    NASA Astrophysics Data System (ADS)

    Cui, Tianyu; Caravelli, Francesco; Ududec, Cozmin

    2018-02-01

    We study the structure of locational marginal prices in day-ahead and real-time wholesale electricity markets. In particular, we consider the case of two North American markets and show that the price correlations contain information on the locational structure of the grid. We study various clustering methods and introduce a type of correlation function based on event synchronization for spiky time series, and another based on string correlations of location names provided by the markets. This allows us to reconstruct aspects of the locational structure of the grid.

  16. Optical information-processing systems and architectures II; Proceedings of the Meeting, San Diego, CA, July 9-13, 1990

    NASA Astrophysics Data System (ADS)

    Javidi, Bahram

    The present conference discusses topics in the fields of neural networks, acoustooptic signal processing, pattern recognition, phase-only processing, nonlinear signal processing, image processing, optical computing, and optical information processing. Attention is given to the optical implementation of an inner-product neural associative memory, optoelectronic associative recall via motionless-head/parallel-readout optical disk, a compact real-time acoustooptic image correlator, a multidimensional synthetic estimation filter, and a light-efficient joint transform optical correlator. Also discussed are a high-resolution spatial light modulator, compact real-time interferometric Fourier-transform processors, a fast decorrelation algorithm for permutation arrays, the optical interconnection of optical modules, and carry-free optical binary adders.

  17. Detection of Alicyclobacillus spp. in Fruit Juice by Combination of Immunomagnetic Separation and a SYBR Green I Real-Time PCR Assay

    PubMed Central

    Yuan, Yahong; Liu, Bin; Wang, Ling; Yue, Tianli

    2015-01-01

    An approach based on immunomagnetic separation (IMS) and SYBR Green I real-time PCR (real-time PCR) with species-specific primers and melting curve analysis was proposed as a rapid and effective method for detecting Alicyclobacillus spp. in fruit juices. Specific primers targeting the 16S rDNA sequences of Alicyclobacillus spp. were designed and then confirmed by the amplification of DNA extracted from standard strains and isolates. Spiked samples containing known amounts of target bacteria were used to obtain standard curves; the correlation coefficient was greater than 0.986 and the real-time PCR amplification efficiencies were 98.9%- 101.8%. The detection limit of the testing system was 2.8×101 CFU/mL. The coefficient of variation for intra-assay and inter-assay variability were all within the acceptable limit of 5%. Besides, the performance of the IMS-real-time PCR assay was further investigated by detecting naturally contaminated kiwi fruit juice; the sensitivity, specificity and accuracy were 91.7%, 95.9% and 95.3%, respectively. The established IMS-real-time PCR procedure provides a new method for identification and quantitative detection of Alicyclobacillus spp. in fruit juice. PMID:26488469

  18. Real-Time Robust Tracking for Motion Blur and Fast Motion via Correlation Filters.

    PubMed

    Xu, Lingyun; Luo, Haibo; Hui, Bin; Chang, Zheng

    2016-09-07

    Visual tracking has extensive applications in intelligent monitoring and guidance systems. Among state-of-the-art tracking algorithms, Correlation Filter methods perform favorably in robustness, accuracy and speed. However, it also has shortcomings when dealing with pervasive target scale variation, motion blur and fast motion. In this paper we proposed a new real-time robust scheme based on Kernelized Correlation Filter (KCF) to significantly improve performance on motion blur and fast motion. By fusing KCF and STC trackers, our algorithm also solve the estimation of scale variation in many scenarios. We theoretically analyze the problem for CFs towards motions and utilize the point sharpness function of the target patch to evaluate the motion state of target. Then we set up an efficient scheme to handle the motion and scale variation without much time consuming. Our algorithm preserves the properties of KCF besides the ability to handle special scenarios. In the end extensive experimental results on benchmark of VOT datasets show our algorithm performs advantageously competed with the top-rank trackers.

  19. Detection of bacteria and fungi in blood of patients with febrile neutropenia by real-time PCR with universal primers and probes.

    PubMed

    Teranishi, Hideto; Ohzono, Nanae; Inamura, Norikazu; Kato, Atsushi; Wakabayashi, Tokio; Akaike, Hiroto; Terada, Kihei; Ouchi, Kazunobu

    2015-03-01

    Febrile neutropenia is the main treatment-related cause of mortality in cancer patients. During June 2012 to April 2014, 97 blood culture samples were collected from patients receiving chemotherapy for hematological malignancy and cancer with febrile neutropenia episodes (FNEs). The samples were examined for the presence of bacteria and fungi using real-time PCR amplification and sequencing of 16S and 18S rRNA genes. Bacteria were identified in 20 of 97 samples (20.6%) by the real-time PCR assay and in 10 of 97 (10.3%) samples by blood culture. In 6 blood culture-positive samples, the real-time PCR assay detected the same type of bacteria. No fungi were detected by the real-time PCR assay or blood culture. During antibiotic therapy, all samples were negative by blood culture, but the real-time PCR assay yielded a positive result in 2 cases of 2 (100%). The bacterial DNA copy number was not well correlated with the serum C-reactive protein titer of patients with FNEs. We conclude that a real-time PCR assay could provide better detection of causative microbes' in a shorter time, and with a smaller blood sample than blood culture. Using a real-time PCR assay in combination with blood culture could improve microbiological documentation of FNEs. Copyright © 2014 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  20. Correlative atomic force microscopy quantitative imaging-laser scanning confocal microscopy quantifies the impact of stressors on live cells in real-time.

    PubMed

    Bhat, Supriya V; Sultana, Taranum; Körnig, André; McGrath, Seamus; Shahina, Zinnat; Dahms, Tanya E S

    2018-05-29

    There is an urgent need to assess the effect of anthropogenic chemicals on model cells prior to their release, helping to predict their potential impact on the environment and human health. Laser scanning confocal microscopy (LSCM) and atomic force microscopy (AFM) have each provided an abundance of information on cell physiology. In addition to determining surface architecture, AFM in quantitative imaging (QI) mode probes surface biochemistry and cellular mechanics using minimal applied force, while LSCM offers a window into the cell for imaging fluorescently tagged macromolecules. Correlative AFM-LSCM produces complimentary information on different cellular characteristics for a comprehensive picture of cellular behaviour. We present a correlative AFM-QI-LSCM assay for the simultaneous real-time imaging of living cells in situ, producing multiplexed data on cell morphology and mechanics, surface adhesion and ultrastructure, and real-time localization of multiple fluorescently tagged macromolecules. To demonstrate the broad applicability of this method for disparate cell types, we show altered surface properties, internal molecular arrangement and oxidative stress in model bacterial, fungal and human cells exposed to 2,4-dichlorophenoxyacetic acid. AFM-QI-LSCM is broadly applicable to a variety of cell types and can be used to assess the impact of any multitude of contaminants, alone or in combination.

  1. Real time evolution at finite temperatures with operator space matrix product states

    NASA Astrophysics Data System (ADS)

    Pižorn, Iztok; Eisler, Viktor; Andergassen, Sabine; Troyer, Matthias

    2014-07-01

    We propose a method to simulate the real time evolution of one-dimensional quantum many-body systems at finite temperature by expressing both the density matrices and the observables as matrix product states. This allows the calculation of expectation values and correlation functions as scalar products in operator space. The simulations of density matrices in inverse temperature and the local operators in the Heisenberg picture are independent and result in a grid of expectation values for all intermediate temperatures and times. Simulations can be performed using real arithmetics with only polynomial growth of computational resources in inverse temperature and time for integrable systems. The method is illustrated for the XXZ model and the single impurity Anderson model.

  2. Scale-invariant structure of energy fluctuations in real earthquakes

    NASA Astrophysics Data System (ADS)

    Wang, Ping; Chang, Zhe; Wang, Huanyu; Lu, Hong

    2017-11-01

    Earthquakes are obviously complex phenomena associated with complicated spatiotemporal correlations, and they are generally characterized by two power laws: the Gutenberg-Richter (GR) and the Omori-Utsu laws. However, an important challenge has been to explain two apparently contrasting features: the GR and Omori-Utsu laws are scale-invariant and unaffected by energy or time scales, whereas earthquakes occasionally exhibit a characteristic energy or time scale, such as with asperity events. In this paper, three high-quality datasets on earthquakes were used to calculate the earthquake energy fluctuations at various spatiotemporal scales, and the results reveal the correlations between seismic events regardless of their critical or characteristic features. The probability density functions (PDFs) of the fluctuations exhibit evidence of another scaling that behaves as a q-Gaussian rather than random process. The scaling behaviors are observed for scales spanning three orders of magnitude. Considering the spatial heterogeneities in a real earthquake fault, we propose an inhomogeneous Olami-Feder-Christensen (OFC) model to describe the statistical properties of real earthquakes. The numerical simulations show that the inhomogeneous OFC model shares the same statistical properties with real earthquakes.

  3. A pilot study characterizing real time exposures to particulate matter and carbon monoxide from cookstove related woodsmoke in rural Peru

    NASA Astrophysics Data System (ADS)

    Commodore, Adwoa A.; Hartinger, Stella M.; Lanata, Claudio F.; Mäusezahl, Daniel; Gil, Ana I.; Hall, Daniel B.; Aguilar-Villalobos, Manuel; Naeher, Luke P.

    2013-11-01

    Nearly half of the world's population is exposed to household air pollution (HAP) due to long hours spent in close proximity to unvented cooking fires. We aimed to use PM2.5 and CO measurements to characterize exposure to cookstove generated woodsmoke in real time among control (n = 10) and intervention (n = 9) households in San Marcos, Cajamarca Region, Peru. Real time personal particulate matter with an aerodynamic diameter ≤2.5 μm (PM2.5), and personal and kitchen carbon monoxide (CO) samples were taken. Control households used a number of stoves including open fire and chimney stoves while intervention households used study-promoted chimney stoves. Measurements were categorized into lunch (9 am-1 pm) and dinner (3 pm-7 pm) periods, where applicable, to adjust for a wide range of sampling periods (2.8-13.1 h). During the 4-h time periods, mean personal PM2.5 exposures were correlated with personal CO exposures during lunch (r = 0.67 p = 0.024 n = 11) and dinner (r = 0.72 p = 0.0011 n = 17) in all study households. Personal PM2.5 exposures and kitchen CO concentrations were also correlated during lunch (r = 0.76 p = 0.018 n = 9) and dinner (r = 0.60 p = 0.018 n = 15). CO may be a useful indicator of PM during 4-h time scales measured in real time, particularly during high woodsmoke exposures, particularly during residential biomass cooking.

  4. RealTime Physics: Active learning laboratory

    NASA Astrophysics Data System (ADS)

    Thornton, Ronald K.; Sokoloff, David R.

    1997-03-01

    Our research shows that student learning of physics concepts in introductory physics courses is enhanced by the use of special guided discovery laboratory curricula which embody the results of educational research and which are supported by the use of the Tools for Scientific Thinking microcomputer-based laboratory (MBL) tools. In this paper we first describe the general characteristics of the research-based RealTime Physics laboratory curricula developed for use in introductory physics classes in colleges, universities and high schools. We then describe RealTime Physics Mechanics in detail. Finally we examine student learning of dynamics in traditional physics courses and in courses using RealTime Physics Mechanics, primarily by the use of correlated questions on the Force and Motion Conceptual Evaluation. We present considerable evidence that students who use the new laboratory curricula demonstrate significantly improved learning and retention of dynamics concepts compared to students taught by traditional methods.

  5. Decay of Complex-Time Determinantal and Pfaffian Correlation Functionals in Lattices

    NASA Astrophysics Data System (ADS)

    Aza, N. J. B.; Bru, J.-B.; de Siqueira Pedra, W.

    2018-04-01

    We supplement the determinantal and Pfaffian bounds of Sims and Warzel (Commun Math Phys 347:903-931, 2016) for many-body localization of quasi-free fermions, by considering the high dimensional case and complex-time correlations. Our proof uses the analyticity of correlation functions via the Hadamard three-line theorem. We show that the dynamical localization for the one-particle system yields the dynamical localization for the many-point fermionic correlation functions, with respect to the Hausdorff distance in the determinantal case. In Sims and Warzel (2016), a stronger notion of decay for many-particle configurations was used but only at dimension one and for real times. Considering determinantal and Pfaffian correlation functionals for complex times is important in the study of weakly interacting fermions.

  6. Decay of Complex-Time Determinantal and Pfaffian Correlation Functionals in Lattices

    NASA Astrophysics Data System (ADS)

    Aza, N. J. B.; Bru, J.-B.; de Siqueira Pedra, W.

    2018-06-01

    We supplement the determinantal and Pfaffian bounds of Sims and Warzel (Commun Math Phys 347:903-931, 2016) for many-body localization of quasi-free fermions, by considering the high dimensional case and complex-time correlations. Our proof uses the analyticity of correlation functions via the Hadamard three-line theorem. We show that the dynamical localization for the one-particle system yields the dynamical localization for the many-point fermionic correlation functions, with respect to the Hausdorff distance in the determinantal case. In Sims and Warzel (2016), a stronger notion of decay for many-particle configurations was used but only at dimension one and for real times. Considering determinantal and Pfaffian correlation functionals for complex times is important in the study of weakly interacting fermions.

  7. Self-learning health monitoring algorithm in composite structures

    NASA Astrophysics Data System (ADS)

    Grassia, Luigi; Iannone, Michele; Califano, America; D'Amore, Alberto

    2018-02-01

    The paper describes a system that it is able of monitoring the health state of a composite structure in real time. The hardware of the system consists of a wire of strain sensors connected to a control unit. The software of the system elaborates the strain data and in real time is able to detect the presence of an eventual damage of the structures monitored with the strain sensors. The algorithm requires as input only the strains of the monitored structured measured on real time, i.e. those strains coming from the deformations of the composite structure due to the working loads. The health monitoring system does not require any additional device to interrogate the structure as often used in the literature, instead it is based on a self-learning procedure. The strain data acquired when the structure is healthy are used to set up the correlations between the strain in different positions of structure by means of neural network. Once the correlations between the strains in different position have been set up, these correlations act as a fingerprint of the healthy structure. In case of damage the correlation between the strains in the position of the structure near the damage will change due to the change of the stiffness of the structure caused by the damage. The developed software is able to recognize the change of the transfer function between the strains and consequently is able to detect the damage.

  8. Comparison of Abbott and Da-an real-time PCR for quantitating serum HBV DNA.

    PubMed

    Qiu, Ning; Li, Rui; Yu, Jian-Guo; Yang, Wen; Zhang, Wei; An, Yong; Li, Tong; Liu, Xue-En; Zhuang, Hui

    2014-09-07

    To compare the performance of the Da-an real-time hepatitis B virus (HBV) DNA assay and Abbott RealTime HBV assay. HBV DNA standards as well as a total of 180 clinical serum samples from patients with chronic hepatitis B were measured using the Abbott and Da-an real-time polymerase chain reaction (PCR) assays. Correlation and Bland-Altman plot analysis was used to compare the performance of the Abbott and Da-an assays. The HBV DNA levels were logarithmically transformed for analysis. All statistical analyses were performed using SPSS for Windows version 18.0. The correlation between the two assays was analyzed by Pearson's correlation and linear regression. The Bland-Altman plots were used for the analysis of agreement between the two assays. A P value of < 0.05 was considered statistically significant. The HBV DNA values measured by the Abbott or Da-an assay were significantly correlated with the expected values of HBV DNA standards (r = 0.999, for Abbott; r = 0.987, for Da-an, P < 0.001). A Bland-Altman plot showed good agreement between these two assays in detecting HBV DNA standards. Among the 180 clinical serum samples, 126 were quantifiable by both assays. Fifty-two samples were detectable by the Abbott assay but below the detection limit of the Da-an assay. Moreover, HBV DNA levels measured by the Abbott assay were significantly higher than those of the Da-an assay (6.23 ± 1.76 log IU/mL vs 5.46 ± 1.55 log IU/mL, P < 0.001). A positive correlation was observed between HBV DNA concentrations determined by the two assays in 126 paired samples (r = 0.648, P < 0.001). One hundred and fifteen of 126 (91.3%) specimens tested with both assays were within mean difference ± 1.96 SD of HBV DNA levels. The Da-an assay presented lower sensitivity and a narrower linear range as compared to the Abbott assay, suggesting the need to be improved.

  9. Method of Individual Adjustment for 3D CT Analysis: Linear Measurement.

    PubMed

    Kim, Dong Kyu; Choi, Dong Hun; Lee, Jeong Woo; Yang, Jung Dug; Chung, Ho Yun; Cho, Byung Chae; Choi, Kang Young

    2016-01-01

    Introduction . We aim to regularize measurement values in three-dimensional (3D) computed tomography (CT) reconstructed images for higher-precision 3D analysis, focusing on length-based 3D cephalometric examinations. Methods . We measure the linear distances between points on different skull models using Vernier calipers (real values). We use 10 differently tilted CT scans for 3D CT reconstruction of the models and measure the same linear distances from the picture archiving and communication system (PACS). In both cases, each measurement is performed three times by three doctors, yielding nine measurements. The real values are compared with the PACS values. Each PACS measurement is revised based on the display field of view (DFOV) values and compared with the real values. Results . The real values and the PACS measurement changes according to tilt value have no significant correlations ( p > 0.05). However, significant correlations appear between the real values and DFOV-adjusted PACS measurements ( p < 0.001). Hence, we obtain a correlation expression that can yield real physical values from PACS measurements. The DFOV value intervals for various age groups are also verified. Conclusion . Precise confirmation of individual preoperative length and precise analysis of postoperative improvements through 3D analysis is possible, which is helpful for facial-bone-surgery symmetry correction.

  10. Scheme for Terminal Guidance Utilizing Acousto-Optic Correlator.

    DTIC Science & Technology

    longitudinally extending acousto - optic device as index of refraction variation pattern signals. Real time signals corresponding to the scene actually being viewed...by the vehicle are propagated across the stored signals, and the results of an acousto - optic correlation are utilized to determine X and Y error

  11. Segmentation of time series with long-range fractal correlations

    PubMed Central

    Bernaola-Galván, P.; Oliver, J.L.; Hackenberg, M.; Coronado, A.V.; Ivanov, P.Ch.; Carpena, P.

    2012-01-01

    Segmentation is a standard method of data analysis to identify change-points dividing a nonstationary time series into homogeneous segments. However, for long-range fractal correlated series, most of the segmentation techniques detect spurious change-points which are simply due to the heterogeneities induced by the correlations and not to real nonstationarities. To avoid this oversegmentation, we present a segmentation algorithm which takes as a reference for homogeneity, instead of a random i.i.d. series, a correlated series modeled by a fractional noise with the same degree of correlations as the series to be segmented. We apply our algorithm to artificial series with long-range correlations and show that it systematically detects only the change-points produced by real nonstationarities and not those created by the correlations of the signal. Further, we apply the method to the sequence of the long arm of human chromosome 21, which is known to have long-range fractal correlations. We obtain only three segments that clearly correspond to the three regions of different G + C composition revealed by means of a multi-scale wavelet plot. Similar results have been obtained when segmenting all human chromosome sequences, showing the existence of previously unknown huge compositional superstructures in the human genome. PMID:23645997

  12. SU-G-JeP4-12: Real-Time Organ Motion Monitoring Using Ultrasound and KV Fluoroscopy During Lung SBRT Delivery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Omari, E; Tai, A; Li, X

    Purpose: Real-time ultrasound monitoring during SBRT is advantageous in understanding and identifying motion irregularities which may cause geometric misses. In this work, we propose to utilize real-time ultrasound to track the diaphragm in conjunction with periodical kV fluoroscopy to monitor motion of tumor or landmarks during SBRT delivery. Methods: Transabdominal Ultrasound (TAUS) b-mode images were collected from 10 healthy volunteers using the Clarity Autoscan System (Elekta). The autoscan transducer, which has a center frequency of 5 MHz, was utilized for the scans. The acquired images were contoured using the Clarity Automatic Fusion and Contouring workstation software. Monitoring sessions of 5more » minute length were observed and recorded. The position correlation between tumor and diaphragm could be established with periodic kV fluoroscopy periodically acquired during treatment with Elekta XVI. We acquired data using a tissue mimicking ultrasound phantom with embedded spheres placed on a motion stand using ultrasound and kV Fluoroscopy. MIM software was utilized for image fusion. Correlation of diaphragm and target motion was also validated using 4D-MRI and 4D-CBCT. Results: The diaphragm was visualized as a hyperechoic region on the TAUS b-mode images. Volunteer set-up can be adjusted such that TAUS probe will not interfere with treatment beams. A segment of the diaphragm was contoured and selected as our tracking structure. Successful monitoring sessions of the diaphragm were recorded. For some volunteers, diaphragm motion over 2 times larger than the initial motion has been observed during tracking. For the phantom study, we were able to register the 2D kV Fluoroscopy with the US images for position comparison. Conclusion: We demonstrated the feasibility of tracking the diaphragm using real-time ultrasound. Real-time tracking can help in identifying such irregularities in the respiratory motion which is correlated to tumor motion. We also showed the feasibility of acquiring 2D KV Fluoroscopy and registering the images with Ultrasound.« less

  13. Real-time assessment of perioperative behaviors in children and parents: development and validation of the perioperative adult child behavioral interaction scale.

    PubMed

    Sadhasivam, Senthilkumar; Cohen, Lindsey L; Hosu, Liana; Gorman, Kristin L; Wang, Yu; Nick, Todd G; Jou, Jing Fang; Samol, Nancy; Szabova, Alexandra; Hagerman, Nancy; Hein, Elizabeth; Boat, Anne; Varughese, Anna; Kurth, Charles Dean; Willging, J Paul; Gunter, Joel B

    2010-04-01

    Behavior in response to distressful events during outpatient pediatric surgery can contribute to postoperative maladaptive behaviors, such as temper tantrums, nightmares, bed-wetting, and attention seeking. Currently available perioperative behavioral assessment tools have limited utility in guiding interventions to ameliorate maladaptive behaviors because they cannot be used in real time, are only intended to be used during 1 phase of the experience (e.g., perioperative), or provide only a static assessment of the child (e.g., level of anxiety). A simple, reliable, real-time tool is needed to appropriately identify children and parents whose behaviors in response to distressful events at any point in the perioperative continuum could benefit from timely behavioral intervention. Our specific aims were to (1) refine the Perioperative Adult Child Behavioral Interaction Scale (PACBIS) to improve its reliability in identifying perioperative behaviors and (2) validate the refined PACBIS against several established instruments. The PACBIS was used to assess the perioperative behaviors of 89 children aged 3 to 12 years presenting for adenotonsillectomy and their parents. Assessments using the PACBIS were made during perioperative events likely to prove distressing to children and/or parents (perioperative measurement of blood pressure, induction of anesthesia, and removal of the IV catheter before discharge). Static measurements of perioperative anxiety and behavioral compliance during anesthetic induction were made using the modified Yale Preoperative Anxiety Scale and the Induction Compliance Checklist (ICC). Each event was videotaped for later scoring using the Child-Adult Medical Procedure Interaction Scale-Short Form (CAMPIS-SF) and Observational Scale of Behavioral Distress (OSBD). Interrater reliability using linear weighted kappa (kappa(w)) and multiple validations using Spearman correlation coefficients were analyzed. The PACBIS demonstrated good to excellent interrater reliability, with kappa(w) ranging from 0.62 to 0.94. The Child Coping and Child Distress subscores of the PACBIS demonstrated strong concurrent correlations with the modified Yale Preoperative Anxiety Scale, ICC, CAMPIS-SF, and OSBD. The Parent Positive subscore of the PACBIS correlated strongly with the CAMPIS-SF and OSBD, whereas the Parent Negative subscore showed significant correlation with the ICC. The PACBIS has strong construct and predictive validities. The PACBIS is a simple, easy to use, real-time instrument to evaluate perioperative behaviors of both children and parents. It has good to excellent interrater reliability and strong concurrent validity against currently accepted scales. The PACBIS offers a means to identify maladaptive child or parental behaviors in real time, making it possible to intervene to modify such behaviors in a timely fashion.

  14. A VLSI implementation for synthetic aperture radar image processing

    NASA Technical Reports Server (NTRS)

    Premkumar, A.; Purviance, J.

    1990-01-01

    A simple physical model for the Synthetic Aperture Radar (SAR) is presented. This model explains the one dimensional and two dimensional nature of the received SAR signal in the range and azimuth directions. A time domain correlator, its algorithm, and features are explained. The correlator is ideally suited for VLSI implementation. A real time SAR architecture using these correlators is proposed. In the proposed architecture, the received SAR data is processed using one dimensional correlators for determining the range while two dimensional correlators are used to determine the azimuth of a target. The architecture uses only three different types of custom VLSI chips and a small amount of memory.

  15. In vivo time-gated diffuse correlation spectroscopy at quasi-null source-detector separation.

    PubMed

    Pagliazzi, M; Sekar, S Konugolu Venkata; Di Sieno, L; Colombo, L; Durduran, T; Contini, D; Torricelli, A; Pifferi, A; Mora, A Dalla

    2018-06-01

    We demonstrate time domain diffuse correlation spectroscopy at quasi-null source-detector separation by using a fast time-gated single-photon avalanche diode without the need of time-tagging electronics. This approach allows for increased photon collection, simplified real-time instrumentation, and reduced probe dimensions. Depth discriminating, quasi-null distance measurement of blood flow in a human subject is presented. We envision the miniaturization and integration of matrices of optical sensors of increased spatial resolution and the enhancement of the contrast of local blood flow changes.

  16. Real-time oil-saturation monitoring in rock cores with low-field NMR.

    PubMed

    Mitchell, J; Howe, A M; Clarke, A

    2015-07-01

    Nuclear magnetic resonance (NMR) provides a powerful suite of tools for studying oil in reservoir core plugs at the laboratory scale. Low-field magnets are preferred for well-log calibration and to minimize magnetic-susceptibility-induced internal gradients in the porous medium. We demonstrate that careful data processing, combined with prior knowledge of the sample properties, enables real-time acquisition and interpretation of saturation state (relative amount of oil and water in the pores of a rock). Robust discrimination of oil and brine is achieved with diffusion weighting. We use this real-time analysis to monitor the forced displacement of oil from porous materials (sintered glass beads and sandstones) and to generate capillary desaturation curves. The real-time output enables in situ modification of the flood protocol and accurate control of the saturation state prior to the acquisition of standard NMR core analysis data, such as diffusion-relaxation correlations. Although applications to oil recovery and core analysis are demonstrated, the implementation highlights the general practicality of low-field NMR as an inline sensor for real-time industrial process control. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Quantification of Wilms' tumor 1 mRNA by digital polymerase chain reaction.

    PubMed

    Koizumi, Yuki; Furuya, Daisuke; Endo, Teruo; Asanuma, Kouichi; Yanagihara, Nozomi; Takahashi, Satoshi

    2018-02-01

    Wilms' tumor 1 (WT1) is overexpressed in various hematopoietic tumors and widely used as a marker of minimal residual disease. WT1 mRNA has been analyzed using quantitative real-time polymerase chain reaction (real-time PCR). In the present study, we analyzed 40 peripheral blood and bone marrow samples obtained from cases of acute myeloid leukemia, acute lymphoblastic leukemia, and myelodysplastic syndrome at Sapporo Medical University Hospital from April 2012 to January 2015. We performed quantification of WT1 was performed using QuantStudio 3D Digital PCR System (Thermo Fisher Scientific‎) and compared the results between digital PCR and real-time PCR technology. The correlation between digital PCR and real-time PCR was very strong (R = 0.99), and the detection limits of the two methods were equivalent. Digital PCR was able to accurately detect lower WT levels compared with real-time PCR. Digital PCR technology can thus be utilized to predict WT1/ABL1 expression level accurately and should thus be useful for diagnosis or the evaluation of drug efficiency in patients with leukemia.

  18. Evaluation of a shortened QIAsymphony DNA extraction protocol for stool samples using a multiplex real-time PCR for the detection of enteric pathogens.

    PubMed

    van Zanten, E; Wisselink, G J; Stoll, S; Alvarez, R; Kooistra-Smid, A M D

    2011-02-01

    A shortened DNA extraction protocol for the QIAsymphony SP was evaluated by quantitative and qualitative comparison of real-time PCR results of 150 co-extracted stool samples. The average ∆Cycle threshold value for positive pathogenic targets was 0.28 Ct. A consensus of 96.91%, with a correlation coefficient of 0.9880 was recorded. Copyright © 2010 Elsevier B.V. All rights reserved.

  19. Real-time three-dimensional digital image correlation for biomedical applications

    NASA Astrophysics Data System (ADS)

    Wu, Rong; Wu, Hua; Arola, Dwayne; Zhang, Dongsheng

    2016-10-01

    Digital image correlation (DIC) has been successfully applied for evaluating the mechanical behavior of biological tissues. A three-dimensional (3-D) DIC system has been developed and applied to examining the motion of bones in the human foot. To achieve accurate, real-time displacement measurements, an algorithm including matching between sequential images and image pairs has been developed. The system was used to monitor the movement of markers which were attached to a precisely motorized stage. The accuracy of the proposed technique for in-plane and out-of-plane measurements was found to be -0.25% and 1.17%, respectively. Two biomedical applications were presented. In the experiment involving the foot arch, a human cadaver lower leg and foot specimen were subjected to vertical compressive loads up to 700 N at a rate of 10 N/s and the 3-D motions of bones in the foot were monitored in real time. In the experiment involving distal tibio fibular syndesmosis, a human cadaver lower leg and foot specimen were subjected to a monotonic rotational torque up to 5 Nm at a speed of 5 deg per min and the relative displacements of the tibia and fibula were monitored in real time. Results showed that the system could reach a frequency of up to 16 Hz with 6 points measured simultaneously. This technique sheds new lights on measuring 3-D motion of bones in biomechanical studies.

  20. Accuracy of clinical observations of push-off during gait after stroke.

    PubMed

    McGinley, Jennifer L; Morris, Meg E; Greenwood, Ken M; Goldie, Patricia A; Olney, Sandra J

    2006-06-01

    To determine the accuracy (criterion-related validity) of real-time clinical observations of push-off in gait after stroke. Criterion-related validity study of gait observations. Rehabilitation hospital in Australia. Eleven participants with stroke and 8 treating physical therapists. Not applicable. Pearson product-moment correlation between physical therapists' observations of push-off during gait and criterion measures of peak ankle power generation from a 3-dimensional motion analysis system. A high correlation was obtained between the observational ratings and the measurements of peak ankle power generation (Pearson r =.98). The standard error of estimation of ankle power generation was .32W/kg. Physical therapists can make accurate real-time clinical observations of push-off during gait following stroke.

  1. Toward real-time quantum imaging with a single pixel camera

    DOE PAGES

    Lawrie, B. J.; Pooser, R. C.

    2013-03-19

    In this paper, we present a workbench for the study of real-time quantum imaging by measuring the frame-by-frame quantum noise reduction of multi-spatial-mode twin beams generated by four wave mixing in Rb vapor. Exploiting the multiple spatial modes of this squeezed light source, we utilize spatial light modulators to selectively pass macropixels of quantum correlated modes from each of the twin beams to a high quantum efficiency balanced detector. Finally, in low-light-level imaging applications, the ability to measure the quantum correlations between individual spatial modes and macropixels of spatial modes with a single pixel camera will facilitate compressive quantum imagingmore » with sensitivity below the photon shot noise limit.« less

  2. CINCH (confocal incoherent correlation holography) super resolution fluorescence microscopy based upon FINCH (Fresnel incoherent correlation holography).

    PubMed

    Siegel, Nisan; Storrie, Brian; Bruce, Marc; Brooker, Gary

    2015-02-07

    FINCH holographic fluorescence microscopy creates high resolution super-resolved images with enhanced depth of focus. The simple addition of a real-time Nipkow disk confocal image scanner in a conjugate plane of this incoherent holographic system is shown to reduce the depth of focus, and the combination of both techniques provides a simple way to enhance the axial resolution of FINCH in a combined method called "CINCH". An important feature of the combined system allows for the simultaneous real-time image capture of widefield and holographic images or confocal and confocal holographic images for ready comparison of each method on the exact same field of view. Additional GPU based complex deconvolution processing of the images further enhances resolution.

  3. Research on Optimization of GLCM Parameter in Cell Classification

    NASA Astrophysics Data System (ADS)

    Zhang, Xi-Kun; Hou, Jie; Hu, Xin-Hua

    2016-05-01

    Real-time classification of biological cells according to their 3D morphology is highly desired in a flow cytometer setting. Gray level co-occurrence matrix (GLCM) algorithm has been developed to extract feature parameters from measured diffraction images ,which are too complicated to coordinate with the real-time system for a large amount of calculation. An optimization of GLCM algorithm is provided based on correlation analysis of GLCM parameters. The results of GLCM analysis and subsequent classification demonstrate optimized method can lower the time complexity significantly without loss of classification accuracy.

  4. Real-time radiography support for Titan LAM

    NASA Astrophysics Data System (ADS)

    Anderson, M. G.

    1992-07-01

    This paper discusses real-time radiography (RTR) support for the Titan Lightweight Analog Motor (LAM) cold gas tests. RTR was used as a diagnostic technique to measure propellant deformation within the motors as gaseous nitrogen, at various pressures, was flowed over the propellant grain. The data consisted of video images that correlated the propellant deformation to time and to chamber pressure. Measurements were made on three propellant configurations in 17 tests. Specific issues addressed include the approach taken to gather the data, the system layout, and image processing techniques used to interpret the data.

  5. Evaluating the influence of wastewater composition on the growth of Microthrix parvicella by GCxGC/qMS and real-time PCR.

    PubMed

    Dunkel, Thiemo; de León Gallegos, Erika Lizette; Schönsee, Carina D; Hesse, Tobias; Jochmann, Maik; Wingender, Jost; Denecke, Martin

    2016-01-01

    This study underlines the significance of long chain fatty acid (LCFA) content in wastewater influents as an influencing factor promoting the growth of Candidatus 'Microthrix parvicella' (M. parvicella), the most common filamentous bacteria causing foam in activated sludge systems worldwide. Quantification of M. parvicella by real-time polymerase chain reaction (real-time PCR) and analysis of LCFAs by means of two-dimensional gas chromatography coupled with mass spectrometry (GCxGC/qMS), involving solid phase micro-extraction (SPME) to enhance sensitivity, were combined for the first time as a monitoring tool. The results indicate a highly significant correlation between the abundance of M. parvicella and the total LCFA loading (r = 0.96) and linolenic acid C18:3 (r = 0.98) in particular. Additionally, comparison of slope values for the direct correlations of all significant LCFAs found in the analyses showed that the influence of LCFAs on M. parvicella growth increases with an increasing degree of unsaturation of carbon chains. These findings suggest that by removing lipid compounds from the incoming waters, substrate availability would be limited for M. parvicella. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Real-Time Assessment of Mechanical Tissue Trauma in Surgery.

    PubMed

    Chandler, James H; Mushtaq, Faisal; Moxley-Wyles, Benjamin; West, Nicholas P; Taylor, Gregory W; Culmer, Peter R

    2017-10-01

    This work presents a method to assess and prevent tissue trauma in real-time during surgery. Tissue trauma occurs routinely during laparoscopic surgery with potentially severe consequences. As such, it is crucial that a surgeon is able to regulate the pressure exerted by surgical instruments. We propose a novel method to assess the onset of tissue trauma by considering the mechanical response of tissue as it is loaded in real-time. We conducted a parametric study using a lab-based grasping model and differing load conditions. Mechanical stress-time data were analyzed to characterize the tissue response to grasps. Qualitative and quantitative histological analyses were performed to inspect damage characteristics of the tissue under different load conditions. These were correlated against the mechanical measures to identify the nature of trauma onset with respect to our predictive metric. Results showed increasing tissue trauma with load and a strong correlation with the mechanical response of the tissue. Load rate and load history also showed a clear effect on tissue response. The proposed method for trauma assessment was effective in identifying damage. The metric can be normalized with respect to loading rate and history, making it feasible in the unconstrained environment of intraoperative surgery. This work demonstrates that tissue trauma can be predicted using mechanical measures in real-time. Applying this technique to laparoscopic tools has the potential to reduce unnecessary tissue trauma and its associated complications by indicating through user feedback or actively regulating the mechanical impact of surgical instruments.

  7. Predicting reduced visibility related crashes on freeways using real-time traffic flow data.

    PubMed

    Hassan, Hany M; Abdel-Aty, Mohamed A

    2013-06-01

    The main objective of this paper is to investigate whether real-time traffic flow data, collected from loop detectors and radar sensors on freeways, can be used to predict crashes occurring at reduced visibility conditions. In addition, it examines the difference between significant factors associated with reduced visibility related crashes to those factors correlated with crashes occurring at clear visibility conditions. Random Forests and matched case-control logistic regression models were estimated. The findings indicated that real-time traffic variables can be used to predict visibility related crashes on freeways. The results showed that about 69% of reduced visibility related crashes were correctly identified. The results also indicated that traffic flow variables leading to visibility related crashes are slightly different from those variables leading to clear visibility crashes. Using time slices 5-15 minutes before crashes might provide an opportunity for the appropriate traffic management centers for a proactive intervention to reduce crash risk in real-time. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. A self optimizing synthetic organic reactor system using real-time in-line NMR spectroscopy† †Electronic supplementary information (ESI) available: Details about the methodology, LabView scripts, experimental set-ups, additional spectra and self-optimization can be found in the SI. See DOI: 10.1039/c4sc03075c Click here for additional data file.

    PubMed Central

    Sans, Victor; Porwol, Luzian; Dragone, Vincenza

    2015-01-01

    A configurable platform for synthetic chemistry incorporating an in-line benchtop NMR that is capable of monitoring and controlling organic reactions in real-time is presented. The platform is controlled via a modular LabView software control system for the hardware, NMR, data analysis and feedback optimization. Using this platform we report the real-time advanced structural characterization of reaction mixtures, including 19F, 13C, DEPT, 2D NMR spectroscopy (COSY, HSQC and 19F-COSY) for the first time. Finally, the potential of this technique is demonstrated through the optimization of a catalytic organic reaction in real-time, showing its applicability to self-optimizing systems using criteria such as stereoselectivity, multi-nuclear measurements or 2D correlations. PMID:29560211

  9. Impact of the New Abbott mPLUS Feature on Clinical Laboratory Efficiencies of Abbott RealTime Assays for Detection of HIV-1, Hepatitis C Virus, Hepatitis B Virus, Chlamydia trachomatis, and Neisseria gonorrhoeae

    PubMed Central

    Jones, Sara; Wiesneth, Russ; Barry, Cathy; Webb, Erika; Belova, Larissa; Dolan, Peggy; Ho, Shiaolan; Abravaya, Klara; Cloherty, Gavin

    2013-01-01

    Diagnostic laboratories are under increasing pressure to improve and expand their services. Greater flexibility in sample processing is a critical factor that can improve the time to results while reducing reagent waste, making laboratories more efficient and cost-effective. The introduction of the Abbott mPLUS feature, with the capacity for extended use of amplification reagents, significantly increases the flexibility of the m2000 platform and enables laboratories to customize their workflows based on sample arrival patterns. The flexibility in sample batch size offered by mPLUS enables significant reductions in processing times. For hepatitis B virus tests, a reduction in sample turnaround times of up to 30% (105 min) was observed for batches of 12 samples compared with those for batches of 24 samples; for Chlamydia trachomatis/Neisseria gonorrhoeae tests, the ability to run batches of 24 samples reduced the turnaround time by 83% (54 min) compared with that for batches of 48 samples. Excellent correlations between mPLUS and m2000 standard condition results were observed for all RealTime viral load assays evaluated in this study, with correlation r values of 0.998 for all assays tested. For the qualitative RealTime C. trachomatis/N. gonorrhoeae assay, the overall agreements between the two conditions tested were >98% for C. trachomatis and 100% for N. gonorrhoeae. Comparable precision results were observed for the two conditions tested for all RealTime assays. The enhanced mPLUS capability provides clinical laboratories with increased efficiencies to meet increasingly stringent turnaround time requirements without increased costs associated with discarding partially used amplification reagents. PMID:24088850

  10. Impact of the New Abbott mPLUS feature on clinical laboratory efficiencies of abbott RealTime assays for detection of HIV-1, Hepatitis C Virus, Hepatitis B Virus, Chlamydia trachomatis, and Neisseria gonorrhoeae.

    PubMed

    Lucic, Danijela; Jones, Sara; Wiesneth, Russ; Barry, Cathy; Webb, Erika; Belova, Larissa; Dolan, Peggy; Ho, Shiaolan; Abravaya, Klara; Cloherty, Gavin

    2013-12-01

    Diagnostic laboratories are under increasing pressure to improve and expand their services. Greater flexibility in sample processing is a critical factor that can improve the time to results while reducing reagent waste, making laboratories more efficient and cost-effective. The introduction of the Abbott mPLUS feature, with the capacity for extended use of amplification reagents, significantly increases the flexibility of the m2000 platform and enables laboratories to customize their workflows based on sample arrival patterns. The flexibility in sample batch size offered by mPLUS enables significant reductions in processing times. For hepatitis B virus tests, a reduction in sample turnaround times of up to 30% (105 min) was observed for batches of 12 samples compared with those for batches of 24 samples; for Chlamydia trachomatis/Neisseria gonorrhoeae tests, the ability to run batches of 24 samples reduced the turnaround time by 83% (54 min) compared with that for batches of 48 samples. Excellent correlations between mPLUS and m2000 standard condition results were observed for all RealTime viral load assays evaluated in this study, with correlation r values of 0.998 for all assays tested. For the qualitative RealTime C. trachomatis/N. gonorrhoeae assay, the overall agreements between the two conditions tested were >98% for C. trachomatis and 100% for N. gonorrhoeae. Comparable precision results were observed for the two conditions tested for all RealTime assays. The enhanced mPLUS capability provides clinical laboratories with increased efficiencies to meet increasingly stringent turnaround time requirements without increased costs associated with discarding partially used amplification reagents.

  11. Real-Time Assessment of Fatigue in Patients With Multiple Sclerosis: How Does It Relate to Commonly Used Self-Report Fatigue Questionnaires?

    PubMed

    Heine, Martin; van den Akker, Lizanne Eva; Blikman, Lyan; Hoekstra, Trynke; van Munster, Erik; Verschuren, Olaf; Visser-Meily, Anne; Kwakkel, Gert

    2016-11-01

    (1) To assess real-time patterns of fatigue; (2) to assess the association between a real-time fatigue score and 3 commonly used questionnaires (Checklist Individual Strength [CIS] fatigue subscale, Modified Fatigue Impact Scale (MFIS), and Fatigue Severity Scale [FSS]); and (3) to establish factors that confound the association between the real-time fatigue score and the conventional fatigue questionnaires in patients with multiple sclerosis (MS). Cross-sectional study. MS-specialized outpatient facility. Ambulant patients with MS (N=165) experiencing severe self-reported fatigue. Not applicable. A real-time fatigue score was assessed by sending participants 4 text messages on a particular day (How fatigued do you feel at this moment?; score range, 0-10). Latent class growth mixed modeling was used to determine diurnal patterns of fatigue. Regression analyses were used to assess the association between the mean real-time fatigue score and the CIS fatigue subscale, MFIS, and FSS. Significant associations were tested for candidate confounders (eg, disease severity, work status, sleepiness). Four significantly different fatigue profiles were identified by the real-time fatigue score, namely a stable high (n=79), increasing (n=57), stable low (n=16), and decreasing (n=13). The conventional questionnaires correlated poorly (r<.300) with the real-time fatigue score. The Epworth Sleepiness Scale significantly reduced the regression coefficient between the real-time fatigue score and conventional questionnaires, ranging from 15.4% to 35%. Perceived fatigue showed 4 different diurnal patterns in patients with MS. Severity of sleepiness is an important confounder to take into account in the assessment of fatigue. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  12. Self-calibrated correlation imaging with k-space variant correlation functions.

    PubMed

    Li, Yu; Edalati, Masoud; Du, Xingfu; Wang, Hui; Cao, Jie J

    2018-03-01

    Correlation imaging is a previously developed high-speed MRI framework that converts parallel imaging reconstruction into the estimate of correlation functions. The presented work aims to demonstrate this framework can provide a speed gain over parallel imaging by estimating k-space variant correlation functions. Because of Fourier encoding with gradients, outer k-space data contain higher spatial-frequency image components arising primarily from tissue boundaries. As a result of tissue-boundary sparsity in the human anatomy, neighboring k-space data correlation varies from the central to the outer k-space. By estimating k-space variant correlation functions with an iterative self-calibration method, correlation imaging can benefit from neighboring k-space data correlation associated with both coil sensitivity encoding and tissue-boundary sparsity, thereby providing a speed gain over parallel imaging that relies only on coil sensitivity encoding. This new approach is investigated in brain imaging and free-breathing neonatal cardiac imaging. Correlation imaging performs better than existing parallel imaging techniques in simulated brain imaging acceleration experiments. The higher speed enables real-time data acquisition for neonatal cardiac imaging in which physiological motion is fast and non-periodic. With k-space variant correlation functions, correlation imaging gives a higher speed than parallel imaging and offers the potential to image physiological motion in real-time. Magn Reson Med 79:1483-1494, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  13. Development of quantitative real-time PCR for detection and enumeration of Enterobacteriaceae.

    PubMed

    Takahashi, Hajime; Saito, Rumi; Miya, Satoko; Tanaka, Yuichiro; Miyamura, Natsumi; Kuda, Takashi; Kimura, Bon

    2017-04-04

    The family Enterobacteriaceae, members of which are widely distributed in the environment, includes many important human pathogens. In this study, a rapid real-time PCR method targeting rplP, coding for L16 protein, a component of the ribosome large subunit, was developed for enumerating Enterobacteriaceae strains, and its efficiency was evaluated using naturally contaminated food products. The rplP-targeted real-time PCR amplified Enterobacteriaceae species with Ct values of 14.0-22.8, whereas the Ct values for non-Enterobacteriaceae species were >30, indicating the specificity of this method for the Enterobacteriaceae. Using a calibration curve of Ct=-3.025 (log CFU/g)+37.35, which was calculated from individual plots of the cell numbers in different concentrations of 5 Enterobacteriaceae species, the rplP-targeted real-time PCR was applied to 51 food samples. A <1log difference between the real-time PCR and culture methods was obtained in a majority of the food samples (81.8%), with good correlation (r 2 =0.8285). This study demonstrated that the rplP-targeted real-time PCR method could detect and enumerate Enterobacteriaceae species in foods rapidly and accurately, and therefore, it can be used for the microbiological risk analysis of foods. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. A Miniature Forward-imaging B-scan Optical Coherence Tomography Probe to Guide Real-time Laser Ablation

    PubMed Central

    Li, Zhuoyan; Shen, Jin H.; Kozub, John A.; Prasad, Ratna; Lu, Pengcheng; Joos, Karen M.

    2014-01-01

    Background and Objective Investigations have shown that pulsed lasers tuned to 6.1 μm in wavelength are capable of ablating ocular and neural tissue with minimal collateral damage. This study investigated whether a miniature B-scan forward-imaging optical coherence tomography (OCT) probe can be combined with the laser to provide real-time visual feedback during laser incisions. Study Design/Methods and Materials A miniature 25-gauge B-scan forward-imaging OCT probe was developed and combined with a 250 μm hollow-glass waveguide to permit delivery of 6.1 μm laser energy. A gelatin mixture and both porcine corneal and retinal tissues were simultaneously imaged and lased (6.1 μm, 10 Hz, 0.4-0.7 mJ) through air. The ablation studies were observed and recorded in real time. The crater dimensions were measured using OCT imaging software (Bioptigen, Durham, NC). Histological analysis was performed on the ocular tissues. Results The combined miniature forward-imaging OCT and mid-infrared laser-delivery probe successfully imaged real-time tissue ablation in gelatin, corneal tissue, and retinal tissue. Application of a constant number of 60 pulses at 0.5 mJ/pulse to the gelatin resulted in a mean crater depth of 123 ± 15 μm. For the corneal tissue, there was a significant correlation between the number of pulses used and depth of the lased hole (Pearson correlation coefficient = 0.82; P = 0.0002). Histological analysis of the cornea and retina tissues showed discrete holes with minimal thermal damage. Conclusions A combined miniature OCT and laser -delivery probe can monitor real-time tissue laser ablation. With additional testing and improvements, this novel instrument has the future possibility of effectively guiding surgeries by simultaneously imaging and ablating tissue. PMID:24648326

  15. Statistical test for ΔρDCCA cross-correlation coefficient

    NASA Astrophysics Data System (ADS)

    Guedes, E. F.; Brito, A. A.; Oliveira Filho, F. M.; Fernandez, B. F.; de Castro, A. P. N.; da Silva Filho, A. M.; Zebende, G. F.

    2018-07-01

    In this paper we propose a new statistical test for ΔρDCCA, Detrended Cross-Correlation Coefficient Difference, a tool to measure contagion/interdependence effect in time series of size N at different time scale n. For this proposition we analyzed simulated and real time series. The results showed that the statistical significance of ΔρDCCA depends on the size N and the time scale n, and we can define a critical value for this dependency in 90%, 95%, and 99% of confidence level, as will be shown in this paper.

  16. Improved Short-Term Clock Prediction Method for Real-Time Positioning.

    PubMed

    Lv, Yifei; Dai, Zhiqiang; Zhao, Qile; Yang, Sheng; Zhou, Jinning; Liu, Jingnan

    2017-06-06

    The application of real-time precise point positioning (PPP) requires real-time precise orbit and clock products that should be predicted within a short time to compensate for the communication delay or data gap. Unlike orbit correction, clock correction is difficult to model and predict. The widely used linear model hardly fits long periodic trends with a small data set and exhibits significant accuracy degradation in real-time prediction when a large data set is used. This study proposes a new prediction model for maintaining short-term satellite clocks to meet the high-precision requirements of real-time clocks and provide clock extrapolation without interrupting the real-time data stream. Fast Fourier transform (FFT) is used to analyze the linear prediction residuals of real-time clocks. The periodic terms obtained through FFT are adopted in the sliding window prediction to achieve a significant improvement in short-term prediction accuracy. This study also analyzes and compares the accuracy of short-term forecasts (less than 3 h) by using different length observations. Experimental results obtained from International GNSS Service (IGS) final products and our own real-time clocks show that the 3-h prediction accuracy is better than 0.85 ns. The new model can replace IGS ultra-rapid products in the application of real-time PPP. It is also found that there is a positive correlation between the prediction accuracy and the short-term stability of on-board clocks. Compared with the accuracy of the traditional linear model, the accuracy of the static PPP using the new model of the 2-h prediction clock in N, E, and U directions is improved by about 50%. Furthermore, the static PPP accuracy of 2-h clock products is better than 0.1 m. When an interruption occurs in the real-time model, the accuracy of the kinematic PPP solution using 1-h clock prediction product is better than 0.2 m, without significant accuracy degradation. This model is of practical significance because it solves the problems of interruption and delay in data broadcast in real-time clock estimation and can meet the requirements of real-time PPP.

  17. Feasibility of real-time MR thermal dose mapping for predicting radiofrequency ablation outcome in the myocardium in vivo.

    PubMed

    Toupin, Solenn; Bour, Pierre; Lepetit-Coiffé, Matthieu; Ozenne, Valéry; Denis de Senneville, Baudouin; Schneider, Rainer; Vaussy, Alexis; Chaumeil, Arnaud; Cochet, Hubert; Sacher, Frédéric; Jaïs, Pierre; Quesson, Bruno

    2017-01-25

    Clinical treatment of cardiac arrhythmia by radiofrequency ablation (RFA) currently lacks quantitative and precise visualization of lesion formation in the myocardium during the procedure. This study aims at evaluating thermal dose (TD) imaging obtained from real-time magnetic resonance (MR) thermometry on the heart as a relevant indicator of the thermal lesion extent. MR temperature mapping based on the Proton Resonance Frequency Shift (PRFS) method was performed at 1.5 T on the heart, with 4 to 5 slices acquired per heartbeat. Respiratory motion was compensated using navigator-based slice tracking. Residual in-plane motion and related magnetic susceptibility artifacts were corrected online. The standard deviation of temperature was measured on healthy volunteers (N = 5) in both ventricles. On animals, the MR-compatible catheter was positioned and visualized in the left ventricle (LV) using a bSSFP pulse sequence with active catheter tracking. Twelve MR-guided RFA were performed on three sheep in vivo at various locations in left ventricle (LV). The dimensions of the thermal lesions measured on thermal dose images, on 3D T1-weighted (T1-w) images acquired immediately after the ablation and at gross pathology were correlated. MR thermometry uncertainty was 1.5 °C on average over more than 96% of the pixels covering the left and right ventricles, on each volunteer. On animals, catheter repositioning in the LV with active slice tracking was successfully performed and each ablation could be monitored in real-time by MR thermometry and thermal dosimetry. Thermal lesion dimensions on TD maps were found to be highly correlated with those observed on post-ablation T1-w images (R = 0.87) that also correlated (R = 0.89) with measurements at gross pathology. Quantitative TD mapping from real-time rapid CMR thermometry during catheter-based RFA is feasible. It provides a direct assessment of the lesion extent in the myocardium with precision in the range of one millimeter. Real-time MR thermometry and thermal dosimetry may improve safety and efficacy of the RFA procedure by offering a reliable indicator of therapy outcome during the procedure.

  18. A real-time spectroscopic sensor for monitoring laser welding processes.

    PubMed

    Sibillano, Teresa; Ancona, Antonio; Berardi, Vincenzo; Lugarà, Pietro Mario

    2009-01-01

    In this paper we report on the development of a sensor for real time monitoring of laser welding processes based on spectroscopic techniques. The system is based on the acquisition of the optical spectra emitted from the laser generated plasma plume and their use to implement an on-line algorithm for both the calculation of the plasma electron temperature and the analysis of the correlations between selected spectral lines. The sensor has been patented and it is currently available on the market.

  19. Twitter Sentiment Predicts Affordable Care Act Marketplace Enrollment

    PubMed Central

    Sap, Maarten; Schwartz, Andrew; Town, Robert; Baker, Tom; Ungar, Lyle; Merchant, Raina M

    2015-01-01

    Background Traditional metrics of the impact of the Affordable Care Act (ACA) and health insurance marketplaces in the United States include public opinion polls and marketplace enrollment, which are published with a lag of weeks to months. In this rapidly changing environment, a real-time barometer of public opinion with a mechanism to identify emerging issues would be valuable. Objective We sought to evaluate Twitter’s role as a real-time barometer of public sentiment on the ACA and to determine if Twitter sentiment (the positivity or negativity of tweets) could be predictive of state-level marketplace enrollment. Methods We retrospectively collected 977,303 ACA-related tweets in March 2014 and then tested a correlation of Twitter sentiment with marketplace enrollment by state. Results A 0.10 increase in the sentiment score was associated with an 8.7% increase in enrollment at the state level (95% CI 1.32-16.13; P=.02), a correlation that remained significant when adjusting for state Medicaid expansion (P=.02) or use of a state-based marketplace (P=.03). Conclusions This correlation indicates Twitter’s potential as a real-time monitoring strategy for future marketplace enrollment periods; marketplaces could systematically track Twitter sentiment to more rapidly identify enrollment changes and potentially emerging issues. As a repository of free and accessible consumer-generated opinions, this study reveals a novel role for Twitter in the health policy landscape. PMID:25707038

  20. Automated Real-Time Behavioral and Physiological Data Acquisition and Display Integrated with Stimulus Presentation for fMRI

    PubMed Central

    Voyvodic, James T.; Glover, Gary H.; Greve, Douglas; Gadde, Syam

    2011-01-01

    Functional magnetic resonance imaging (fMRI) is based on correlating blood oxygen-level dependent (BOLD) signal fluctuations in the brain with other time-varying signals. Although the most common reference for correlation is the timing of a behavioral task performed during the scan, many other behavioral and physiological variables can also influence fMRI signals. Variations in cardiac and respiratory functions in particular are known to contribute significant BOLD signal fluctuations. Variables such as skin conduction, eye movements, and other measures that may be relevant to task performance can also be correlated with BOLD signals and can therefore be used in image analysis to differentiate multiple components in complex brain activity signals. Combining real-time recording and data management of multiple behavioral and physiological signals in a way that can be routinely used with any task stimulus paradigm is a non-trivial software design problem. Here we discuss software methods that allow users control of paradigm-specific audio–visual or other task stimuli combined with automated simultaneous recording of multi-channel behavioral and physiological response variables, all synchronized with sub-millisecond temporal accuracy. We also discuss the implementation and importance of real-time display feedback to ensure data quality of all recorded variables. Finally, we discuss standards and formats for storage of temporal covariate data and its integration into fMRI image analysis. These neuroinformatics methods have been adopted for behavioral task control at all sites in the Functional Biomedical Informatics Research Network (FBIRN) multi-center fMRI study. PMID:22232596

  1. Real-time and imaginary-time quantum hierarchal Fokker-Planck equations

    NASA Astrophysics Data System (ADS)

    Tanimura, Yoshitaka

    2015-04-01

    We consider a quantum mechanical system represented in phase space (referred to hereafter as "Wigner space"), coupled to a harmonic oscillator bath. We derive quantum hierarchal Fokker-Planck (QHFP) equations not only in real time but also in imaginary time, which represents an inverse temperature. This is an extension of a previous work, in which we studied a spin-boson system, to a Brownian system. It is shown that the QHFP in real time obtained from a correlated thermal equilibrium state of the total system possesses the same form as those obtained from a factorized initial state. A modified terminator for the hierarchal equations of motion is introduced to treat the non-Markovian case more efficiently. Using the imaginary-time QHFP, numerous thermodynamic quantities, including the free energy, entropy, internal energy, heat capacity, and susceptibility, can be evaluated for any potential. These equations allow us to treat non-Markovian, non-perturbative system-bath interactions at finite temperature. Through numerical integration of the real-time QHFP for a harmonic system, we obtain the equilibrium distributions, the auto-correlation function, and the first- and second-order response functions. These results are compared with analytically exact results for the same quantities. This provides a critical test of the formalism for a non-factorized thermal state and elucidates the roles of fluctuation, dissipation, non-Markovian effects, and system-bath coherence. Employing numerical solutions of the imaginary-time QHFP, we demonstrate the capability of this method to obtain thermodynamic quantities for any potential surface. It is shown that both types of QHFP equations can produce numerical results of any desired accuracy. The FORTRAN source codes that we developed, which allow for the treatment of Wigner space dynamics with any potential form (TanimuranFP15 and ImTanimuranFP15), are provided as the supplementary material.

  2. Data Quality Control of the French Permanent Broadband Network in the RESIF Framework.

    NASA Astrophysics Data System (ADS)

    Grunberg, M.; Lambotte, S.; Engels, F.

    2014-12-01

    In the framework of the RESIF (Réseau Sismologique et géodésique Français) project, a new information system is setting up, allowing the improvement of the management and the distribution of high quality data from the different elements of RESIF. Within this information system, EOST (in Strasbourg) is in charge of collecting real-time permanent broadband seismic waveform, and performing Quality Control on these data. The real-time and validated data set are pushed to the French National Distribution Center (Isterre/Grenoble) to make them publicly available. Furthermore EOST hosts the BCSF-ReNaSS, in charge of the French metropolitan seismic bulletin. This allows to benefit from some high-end quality control based on the national and world-wide seismicity. Here we present the real-time seismic data flow from the stations of the French National Broad Band Network to EOST, and then, the data Quality Control procedures that were recently installed, including some new developments.The data Quality Control consists in applying a variety of processes to check the consistency of the whole system from the stations to the data center. This allows us to verify that instruments and data transmission are operating correctly. Moreover, time quality is critical for most of the scientific data applications. To face this challenge and check the consistency of polarities and amplitudes, we deployed several high-end processes including a noise correlation procedure to check for timing accuracy (intrumental time errors result in a time-shift of the whole cross-correlation, clearly distinct from those due to change in medium physical properties), and a systematic comparison of synthetic and real data for teleseismic earthquakes of magnitude larger than 6.5 to detect timing errors as well as polarity and amplitude problems.

  3. Regional Level Influenza Study with Geo-Tagged Twitter Data.

    PubMed

    Wang, Feng; Wang, Haiyan; Xu, Kuai; Raymond, Ross; Chon, Jaime; Fuller, Shaun; Debruyn, Anton

    2016-08-01

    The rich data generated and read by millions of users on social media tells what is happening in the real world in a rapid and accurate fashion. In recent years many researchers have explored real-time streaming data from Twitter for a broad range of applications, including predicting stock markets and public health trend. In this paper we design, implement, and evaluate a prototype system to collect and analyze influenza statuses over different geographical locations with real-time tweet streams. We investigate the correlation between the Twitter flu counts and the official statistics from the Center for Disease Control and Prevention (CDC) and discover that real-time tweet streams capture the dynamics of influenza cases at both national and regional level and could potentially serve as an early warning system of influenza epidemics. Furthermore, we propose a dynamic mathematical model which can forecast Twitter flu counts with high accuracy.

  4. Comparative Evaluation of Four Real-Time PCR Methods for the Quantitative Detection of Epstein-Barr Virus from Whole Blood Specimens.

    PubMed

    Buelow, Daelynn; Sun, Yilun; Tang, Li; Gu, Zhengming; Pounds, Stanley; Hayden, Randall

    2016-07-01

    Monitoring of Epstein-Barr virus (EBV) load in immunocompromised patients has become integral to their care. An increasing number of reagents are available for quantitative detection of EBV; however, there are little published comparative data. Four real-time PCR systems (one using laboratory-developed reagents and three using analyte-specific reagents) were compared with one another for detection of EBV from whole blood. Whole blood specimens seeded with EBV were used to determine quantitative linearity, analytical measurement range, lower limit of detection, and CV for each assay. Retrospective testing of 198 clinical samples was performed in parallel with all methods; results were compared to determine relative quantitative and qualitative performance. All assays showed similar performance. No significant difference was found in limit of detection (3.12-3.49 log10 copies/mL; P = 0.37). A strong qualitative correlation was seen with all assays that used clinical samples (positive detection rates of 89.5%-95.8%). Quantitative correlation of clinical samples across assays was also seen in pairwise regression analysis, with R(2) ranging from 0.83 to 0.95. Normalizing clinical sample results to IU/mL did not alter the quantitative correlation between assays. Quantitative EBV detection by real-time PCR can be performed over a wide linear dynamic range, using three different commercially available reagents and laboratory-developed methods. EBV was detected with comparable sensitivity and quantitative correlation for all assays. Copyright © 2016 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  5. Real-Time Robust Tracking for Motion Blur and Fast Motion via Correlation Filters

    PubMed Central

    Xu, Lingyun; Luo, Haibo; Hui, Bin; Chang, Zheng

    2016-01-01

    Visual tracking has extensive applications in intelligent monitoring and guidance systems. Among state-of-the-art tracking algorithms, Correlation Filter methods perform favorably in robustness, accuracy and speed. However, it also has shortcomings when dealing with pervasive target scale variation, motion blur and fast motion. In this paper we proposed a new real-time robust scheme based on Kernelized Correlation Filter (KCF) to significantly improve performance on motion blur and fast motion. By fusing KCF and STC trackers, our algorithm also solve the estimation of scale variation in many scenarios. We theoretically analyze the problem for CFs towards motions and utilize the point sharpness function of the target patch to evaluate the motion state of target. Then we set up an efficient scheme to handle the motion and scale variation without much time consuming. Our algorithm preserves the properties of KCF besides the ability to handle special scenarios. In the end extensive experimental results on benchmark of VOT datasets show our algorithm performs advantageously competed with the top-rank trackers. PMID:27618046

  6. Unleashing Creativity in Linguistic Discourses through Advertising Skills

    ERIC Educational Resources Information Center

    Suneetha, Y.

    2015-01-01

    Creative fluency is positively correlated with the quantity and quality of talk as well. The fluency gives an indication of the learner's ability to cope with real-time communication. This paper makes a correlative study on nurturing narrative tasks through advertising skills. English advertising exploits from the high adaptability of the English…

  7. Intracellular applications of fluorescence correlation spectroscopy: prospects for neuroscience.

    PubMed

    Kim, Sally A; Schwille, Petra

    2003-10-01

    Based on time-averaging fluctuation analysis of small fluorescent molecular ensembles in equilibrium, fluorescence correlation spectroscopy has recently been applied to investigate processes in the intracellular milieu. The exquisite sensitivity of fluorescence correlation spectroscopy provides access to a multitude of measurement parameters (rates of diffusion, local concentration, states of aggregation and molecular interactions) in real time with fast temporal and high spatial resolution. The introduction of dual-color cross-correlation, imaging, two-photon excitation, and coincidence analysis coupled with fluorescence correlation spectroscopy has expanded the utility of the technique to encompass a wide range of promising applications in living cells that may provide unprecedented insight into understanding the molecular mechanisms of intracellular neurobiological processes.

  8. On the possibility of real time air quality and toxicology assessment using multi-wavelength photoacoustic spectroscopy

    NASA Astrophysics Data System (ADS)

    Ajtai, Tibor; Pinter, Mate; Utry, Noemi; Kiss-Albert, Gergely; Palagyi, Andrea; Manczinger, Laszlo; Vagvölgyi, Csaba; Szabo, Gabor; Bozoki, Zoltan

    2016-04-01

    In this study we present results of field measurement campaigns focusing on the in-situ characterization of absorption spectra and the health relevance of light absorbing carbonaceous (LAC) in the ambient. The absorption spectra is measured @ 266, 355, 532 and 1064 nm by our state-of-the-art four-wavelength photoacoustic instrument, while for health relevance the eco- cito and genotoxicity parameters were measured using standardized methodologies. We experimentally demonstrated a correlation between the toxicities and the measured absorption spectra quantified by its wavelength dependency. Based on this correlation, we present novel possibilities on real-time air quality monitoring. LAC is extensively studied not only because of its considerable climate effects but as a serious air pollutant too. Gradually increasing number of studies demonstrated experimentally that the health effect of LAC is more serious than it is expected based on its share in total atmospheric aerosol mass. Furthermore during many local pollution events LAC not only has dominancy but it is close to exclusivity. Altogether due to its climate and health effects many studies and proposed regulations focus on the physical, chemical and toxicological properties of LAC as well as on its source apportionment. Despites of its importance, there is not yet a widely accepted standard methodology for the real-time and selective identification of LAC. There are many different reasons of that: starting from its complex inherent physicochemical features including many unknown constituents, via masking effect of ambient on the inherent physicochemical properties taking place even in case of a short residence, ending with the lack of reliable instrumentation for its health or source relevant parameters. Therefore, the methodology and instrument development for selective and reliable identification of LAC is timely and important issues in climate and air quality researches. Recently, many studies demonstrated correlation between the chemical compositions and the absorption features of LAC which open up novel possibilities in real time source apportionment and in air quality monitoring.

  9. The Identification and Tracking of Uterine Contractions Using Template Based Cross-Correlation.

    PubMed

    McDonald, Sarah C; Brooker, Graham; Phipps, Hala; Hyett, Jon

    2017-09-01

    The purpose of this paper is to outline a novel method of using template based cross-correlation to identify and track uterine contractions during labour. A purpose built six-channel Electromyography (EMG) device was used to collect data from consenting women during labour and birth. A range of templates were constructed for the purpose of identifying and tracking uterine activity when cross-correlated with the EMG signal. Peak finding techniques were applied on the cross-correlated result to simplify and automate the identification and tracking of contractions. The EMG data showed a unique pattern when a woman was contracting with key features of the contraction signal remaining consistent and identifiable across subjects. Contraction profiles across subjects were automatically identified using template based cross-correlation. Synthetic templates from a rectangular function with a duration of between 5 and 10 s performed best at identifying and tracking uterine activity across subjects. The successful application of this technique provides opportunity for both simple and accurate real-time analysis of contraction data while enabling investigations into the application of techniques such as machine learning which could enable automated learning from contraction data as part of real-time monitoring and post analysis.

  10. CINCH (confocal incoherent correlation holography) super resolution fluorescence microscopy based upon FINCH (Fresnel incoherent correlation holography)

    PubMed Central

    Siegel, Nisan; Storrie, Brian; Bruce, Marc

    2016-01-01

    FINCH holographic fluorescence microscopy creates high resolution super-resolved images with enhanced depth of focus. The simple addition of a real-time Nipkow disk confocal image scanner in a conjugate plane of this incoherent holographic system is shown to reduce the depth of focus, and the combination of both techniques provides a simple way to enhance the axial resolution of FINCH in a combined method called “CINCH”. An important feature of the combined system allows for the simultaneous real-time image capture of widefield and holographic images or confocal and confocal holographic images for ready comparison of each method on the exact same field of view. Additional GPU based complex deconvolution processing of the images further enhances resolution. PMID:26839443

  11. Comparison of Hybrid Capture 2 Assay with Real-time-PCR for Detection and Quantitation of Hepatitis B Virus DNA.

    PubMed

    Majid, Farjana; Jahan, Munira; Lutful Moben, Ahmed; Tabassum, Shahina

    2014-01-01

    Both real-time-polymerase chain reaction (PCR) and hybrid capture 2 (HC2) assay can detect and quantify hepatitis B virus (HBV) DNA. However, real-time-PCR can detect a wide range of HBV DNA, while HC2 assay could not detect lower levels of viremia. The present study was designed to detect and quantify HBV DNA by real-time-PCR and HC2 assay and compare the quantitative data of these two assays. A cross-sectional study was conducted in between July 2010 and June 2011. A total of 66 serologically diagnosed chronic hepatitis B (CHB) patients were selected for the study. Real-time-PCR and HC2 assay was done to detect HBV DNA. Data were analyzed by statistical Package for the social sciences (SPSS). Among 66 serologically diagnosed chronic hepatitis B patients 40 (60.61%) patients had detectable and 26 (39.39%) had undetectable HBV DNA by HC2 assay. Concordant results were obtained for 40 (60.61%) out of these 66 patients by real-time-PCR and HC2 assay with mean viral load of 7.06 ± 1.13 log 10 copies/ml and 6.95 ± 1.08 log 10 copies/ml, respectively. In the remaining 26 patients, HBV DNA was detectable by real-time-PCR in 20 patients (mean HBV DNA level was 3.67 ± 0.72 log 10 copies/ml. However, HBV DNA could not be detectable in six cases by the both assays. The study showed strong correlation (r = 0.915) between real-time-PCR and HC2 assay for the detection and quantification of HBV DNA. HC2 assay may be used as an alternative to real-time-PCR for CHB patients. How to cite this article: Majid F, Jahan M, Moben AL, Tabassum S. Comparison of Hybrid Capture 2 Assay with Real-time-PCR for Detection and Quantitation of Hepatitis B Virus DNA. Euroasian J Hepato-Gastroenterol 2014;4(1):31-35.

  12. Real-Time Imaging System for the OpenPET

    NASA Astrophysics Data System (ADS)

    Tashima, Hideaki; Yoshida, Eiji; Kinouchi, Shoko; Nishikido, Fumihiko; Inadama, Naoko; Murayama, Hideo; Suga, Mikio; Haneishi, Hideaki; Yamaya, Taiga

    2012-02-01

    The OpenPET and its real-time imaging capability have great potential for real-time tumor tracking in medical procedures such as biopsy and radiation therapy. For the real-time imaging system, we intend to use the one-pass list-mode dynamic row-action maximum likelihood algorithm (DRAMA) and implement it using general-purpose computing on graphics processing units (GPGPU) techniques. However, it is difficult to make consistent reconstructions in real-time because the amount of list-mode data acquired in PET scans may be large depending on the level of radioactivity, and the reconstruction speed depends on the amount of the list-mode data. In this study, we developed a system to control the data used in the reconstruction step while retaining quantitative performance. In the proposed system, the data transfer control system limits the event counts to be used in the reconstruction step according to the reconstruction speed, and the reconstructed images are properly intensified by using the ratio of the used counts to the total counts. We implemented the system on a small OpenPET prototype system and evaluated the performance in terms of the real-time tracking ability by displaying reconstructed images in which the intensity was compensated. The intensity of the displayed images correlated properly with the original count rate and a frame rate of 2 frames per second was achieved with average delay time of 2.1 s.

  13. Evaluation of performance across the dynamic range of the Abbott RealTime HIV-1 assay as compared to VERSANT HIV-1 RNA 3.0 and AMPLICOR HIV-1 MONITOR v1.5 using serial dilutions of 39 group M and O viruses.

    PubMed

    Swanson, Priscilla; Huang, Shihai; Abravaya, Klara; de Mendoza, Carmen; Soriano, Vincent; Devare, Sushil G; Hackett, John

    2007-04-01

    Performance of the Abbott m2000 instrument system and the Abbott RealTime HIV-1 assay was evaluated using a panel of 37 group M (subtypes A-D, F, G, CRF01_AE, CRF02_AG and unique recombinant forms) and 2 group O virus isolates. Testing was performed on 273 sample dilutions and compared to VERSANT HIV-1 RNA 3.0 (bDNA) and AMPLICOR HIV-1 MONITOR v1.5 (Monitor v1.5) test results. RealTime HIV-1, bDNA, and Monitor v1.5 tests quantified 87%, 78%, and 81% of samples, respectively. RealTime HIV-1 detected an additional 31 samples at < 40 copies/mL. For group M, RealTime HIV-1 dilution profiles and viral loads were highly correlated with bDNA and Monitor v1.5 values; 87% and 89% of values were within 0.5 log(10) copies/mL. In contrast, the group O viruses were not detected by Monitor v1.5 and were substantially underquantified by approximately 2 log(10) copies/mL in bDNA relative to the RealTime HIV-1 assay. Sequence analysis revealed that RealTime HIV-1 primer/probe binding sites are highly conserved and exhibit fewer nucleotide mismatches relative to Monitor v1.5. The automated m2000 system and RealTime HIV-1 assay offer the advantages of efficient sample processing and throughput with reduced "hands-on" time while providing improved sensitivity, expanded dynamic range and reliable quantification of genetically diverse HIV-1 strains.

  14. Quantitative detection of the potato cyst nematode, Globodera pallida, and the beet cyst nematode, Heterodera schachtii, using Real-Time PCR with SYBR green I dye.

    PubMed

    Madani, Mehrdad; Subbotin, Sergei A; Moens, Maurice

    2005-04-01

    The potato cyst nematode Globodera pallida and the beet cyst nematode Heterodera schachtii are major nematode pests in world agriculture. Precise identification and knowledge about the number of nematodes in field soil are necessary to develop effective integrated pest control. Here we report the results of the Real-Time PCR assay for the rapid detection and quantification of G. pallida and H. schachtii. Using species specific primers and SYBR green I dye, we were able to detect a single second stage juvenile of cyst forming nematodes in samples. The specificity of the reaction was confirmed by the lack of amplification of DNAs from other Heterodera or Globodera species. Validation tests showed a rather high correlation between real numbers of second stage juveniles in a sample and expected numbers detected by Real-Time PCR. Reasons for observed differences in sensitivity and reliability of quantification detection for two species as well as other problems of Real-Time PCR are discussed. The Real-Time PCR assay with SYBR green I dye targeting fragments of the ITS-rDNA provided a sensitive means for the rapid and simultaneous detection and quantification of juveniles of these pests.

  15. Stressors, Appraisal of Stressors, Experienced Stress and Cardiac Response: A Real-Time, Real-Life Investigation of Work Stress in Nurses.

    PubMed

    Johnston, Derek; Bell, Cheryl; Jones, Martyn; Farquharson, Barbara; Allan, Julia; Schofield, Patricia; Ricketts, Ian; Johnston, Marie

    2016-04-01

    Stress in health care professionals may reflect both the work and appraisal of work and impacts on the individuals, their patients, colleagues and managers. The purpose of the present study is to examine physiological and psychological effects of stressors (tasks) and theory-based perceptions of work stressors within and between nurses in real time. During two work shifts, 100 nurses rated experienced stress, affect, fatigue, theory-based measures of work stress and nursing tasks on electronic diaries every 90 min, whereas heart rate and activity were measured continuously. Heart rate was associated with both demand and effort. Experienced stress was related to demand, control, effort and reward. Effort and reward interacted as predicted (but only within people). Results were unchanged when allowance was made for work tasks. Real-time appraisals were more important than actual tasks in predicting both psychological and physiological correlates of stress. At times when effort was high, perceived reward reduced stress.

  16. [Real-time PCR kits for the detection of the African Swine Fever virus].

    PubMed

    Latyshev, O E; Eliseeva, O V; Grebennikova, T V; Verkhovskiĭ, O A; Tsibezov, V V; Chernykh, O Iu; Dzhailidi, G A; Aliper, T I

    2014-01-01

    The results obtained using the diagnostic kit based on real-time polymerase chain reaction to detect the DNA of the African Swine Fever in the pathological material, as well as in the culture fluid, are presented. A high sensitivity and specificity for detection of the DNA in the organs and tissues of animals was shown to be useful for detection in the European Union referentiality reagent kits for DNA detection by real time PCR of ASFV. More rapid and effective method of DNA extraction using columns mini spin Quick gDNA(TM) MiniPrep was suggested and compared to the method of DNA isolation on the inorganic sorbent. High correlation of the results of the DNA detection of ASFV by real-time PCR and antigen detection results ASFV by competitive ELISA obtained with the ELISA SEROTEST/INGEZIM COMRAC PPA was demonstrated. The kit can be used in the veterinary services for effective monitoring of ASFV to contain, eliminate and prevent further spread of the disease.

  17. Inter-laboratory quality control for hormone-dependent gene expression in human breast tumors using real-time reverse transcription-polymerase chain reaction.

    PubMed

    de Cremoux, P; Bieche, I; Tran-Perennou, C; Vignaud, S; Boudou, E; Asselain, B; Lidereau, R; Magdelénat, H; Becette, V; Sigal-Zafrani, B; Spyratos, F

    2004-09-01

    Quantitative reverse transcription-polymerase chain reaction (RT-PCR) used to detect minor changes in specific mRNA concentrations may be associated with poor reproducibility. Stringent quality control is therefore essential at each step of the protocol, including the PCR procedure. We performed inter-laboratory quality control of quantitative PCR between two independent laboratories, using in-house RT-PCR assays on a series of hormone-related target genes in a retrospective consecutive series of 79 breast tumors. Total RNA was reverse transcribed in a single center. Calibration curves were performed for five target genes (estrogen receptor (ER)alpha, ERbeta, progesterone receptor (PR), CYP19 (aromatase) and Ki 67) and for two reference genes (human acidic ribosomal phosphoprotein PO (RPLPO) and TATA box-binding protein (TBP)). Amplification efficiencies of the calibrator were determined for each run and used to calculate mRNA expression. Correlation coefficients were evaluated for each target and each reference gene. A good correlation was observed for all target and reference genes in both centers using their own protocols and kits (P < 0.0001). The correlation coefficients ranged from 0.90 to 0.98 for the various target genes in the two centers. A good correlation was observed between the level of expression of the ERalpha and the PR transcripts (P < 0.001). A weak inverse correlation was observed in both centers between ERalpha and ERbeta levels, but only when TBP was the reference gene. No other correlation was observed with other parameters. Real-time PCR assays allow convenient quantification of target mRNA transcripts and quantification of target-derived nucleic acids in clinical specimens. This study addresses the importance of inter-laboratory quality controls for the use of a panel of real-time PCR assays devoted to clinical samples and protocols and to ensure their appropriate accuracy. This can also facilitate exchanges and multicenter comparison of data.

  18. Sensitivity analysis of water consumption in an office building

    NASA Astrophysics Data System (ADS)

    Suchacek, Tomas; Tuhovcak, Ladislav; Rucka, Jan

    2018-02-01

    This article deals with sensitivity analysis of real water consumption in an office building. During a long-term real study, reducing of pressure in its water connection was simulated. A sensitivity analysis of uneven water demand was conducted during working time at various provided pressures and at various time step duration. Correlations between maximal coefficients of water demand variation during working time and provided pressure were suggested. The influence of provided pressure in the water connection on mean coefficients of water demand variation was pointed out, altogether for working hours of all days and separately for days with identical working hours.

  19. Extracting physical quantities from BES data

    NASA Astrophysics Data System (ADS)

    Fox, Michael; Field, Anthony; Schekochihin, Alexander; van Wyk, Ferdinand; MAST Team

    2015-11-01

    We propose a method to extract the underlying physical properties of turbulence from measurements, thereby facilitating quantitative comparisons between theory and experiment. Beam Emission Spectroscopy (BES) diagnostics record fluctuating intensity time series, which are related to the density field in the plasma through Point-Spread Functions (PSFs). Assuming a suitable form for the correlation function of the underlying turbulence, analytical expressions are derived that relate the correlation parameters of the intensity field: the radial and poloidal correlation lengths and wavenumbers, the correlation time and the fluctuation amplitude, to the equivalent correlation properties of the density field. In many cases, the modification caused by the PSFs is substantial enough to change conclusions about physics. Our method is tested by applying PSFs to the ``real'' density field, generated by non-linear gyrokinetic simulations of MAST, to create synthetic turbulence data, from which the method successfully recovers the correlation function of the ``real'' density field. This method is applied to BES data from MAST to determine the scaling of the 2D structure of the ion-scale turbulence with equilibrium parameters, including the ExB flow shear. Work funded by the Euratom research and training programme 2014-2018 under grant agreement No 633053 and from the RCUK Energy Programme [grant number EP/I501045].

  20. Detection of individual atoms in helium buffer gas and observation of their real-time motion

    NASA Technical Reports Server (NTRS)

    Pan, C. L.; Prodan, J. V.; Fairbank, W. M., Jr.; She, C. Y.

    1980-01-01

    Single atoms are detected and their motion measured for the first time to our knowledge by the fluorescence photon-burst method in the presence of large quantities of buffer gas. A single-clipped digital correlator records the photon burst in real time and displays the atom's transit time across the laser beam. A comparison is made of the special requirements for single-atom detection in vacuum and in a buffer gas. Finally, the probability distribution of the bursts from many atoms is measured. It further proves that the bursts observed on resonance are due to single atoms and not simply to noise fluctuations.

  1. Design and evaluation of an inlet conditioner to dry particles for real-time particle sizers.

    PubMed

    Peters, Thomas M; Riss, Adam L; Holm, Ricky L; Singh, Manisha; Vanderpool, Robert W

    2008-04-01

    Real-time particle sizers provide rapid information about atmospheric particles, particularly peak exposures, which may be important in the development of adverse health outcomes. However, these instruments are subject to erroneous readings in high-humidity environments when compared with measurements from filter-based, federal reference method (FRM) samplers. Laboratory tests were conducted to evaluate the ability of three inlet conditioners to dry aerosol prior to entering a real-time particle sizer for measuring coarse aerosols (Model 3321 Aerodynamic Particle Sizer, APS) under simulated highly humid conditions. Two 30 day field studies in Birmingham, AL, USA were conducted to compare the response of two APSs operated with and without an inlet conditioner to that measured with FRM samplers. In field studies, the correlation of PM(10-2.5) derived from the APS and that measured with the FRM was substantially stronger with an inlet conditioner applied (r2 ranged from 0.91 to 0.99) than with no conditioner (r2 = 0.61). Laboratory experiments confirmed the ability of the heater and desiccant conditioner to remove particle-borne moisture. In field tests, water was found associated with particles across the sizing range of the APS (0.5 microm to 20 microm) when relative humidity was high in Birmingham. Certain types of inlet conditioners may substantially improve the correlation between particulate mass concentration derived from real-time particle sizers and filter-based samplers in humid conditions.

  2. CortiQ-based Real-Time Functional Mapping for Epilepsy Surgery.

    PubMed

    Kapeller, Christoph; Korostenskaja, Milena; Prueckl, Robert; Chen, Po-Ching; Lee, Ki Heyeong; Westerveld, Michael; Salinas, Christine M; Cook, Jane C; Baumgartner, James E; Guger, Christoph

    2015-06-01

    To evaluate the use of the cortiQ-based mapping system (g.tec medication engineering GmbH, Austria) for real-time functional mapping (RTFM) and to compare it to results from electrical cortical stimulation mapping (ESM) and functional magnetic resonance imaging (fMRI). Electrocorticographic activity was recorded in 3 male patients with intractable epilepsy by using cortiQ mapping system and analyzed in real time. Activation related to motor, sensory, and receptive language tasks was determined by evaluating the power of the high gamma frequency band (60-170 Hz). The sensitivity and specificity of RTFM were tested against ESM and fMRI results. "Next-neighbor" approach demonstrated [sensitivity/specificity %] (1) RTFM against ESM: 100.00/79.70 for hand motor; 100.00/73.87 for hand sensory; -/87 for language (it was not identified by the ESM); (2) RTFM against fMRI: 100.00/84.4 for hand motor; 66.70/85.35 for hand sensory; and 87.85/77.70 for language. The results of the quantitative "next-neighbor" RTFM evaluation were concordant to those from ESM and fMRI. The RTFM correlates well with localization of hand motor function provided by ESM and fMRI, which may offer added localization in the operating room and guidance for extraoperative ESM mapping. Real-time functional mapping correlates with fMRI language activation when ESM findings are negative. It has fewer limitations than ESM and greater flexibility in activation paradigms and measuring responses.

  3. Real-Time Continuous Response Spectra Exceedance Calculation

    NASA Astrophysics Data System (ADS)

    Vernon, Frank; Harvey, Danny; Lindquist, Kent; Franke, Mathias

    2017-04-01

    A novel approach is presented for near real-time earthquake alarms for critical structures at distributed locations using real-time estimation of response spectra obtained from near free-field motions. Influential studies dating back to the 1980s identified spectral response acceleration as a key ground motion characteristic that correlates well with observed damage in structures. Thus, monitoring and reporting on exceedance of spectra-based thresholds are useful tools for assessing the potential for damage to facilities or multi-structure campuses based on input ground motions only. With as little as one strong-motion station per site, this scalable approach can provide rapid alarms on the damage status of remote towns, critical infrastructure (e.g., hospitals, schools) and points of interests (e.g., bridges) for a very large number of locations enabling better rapid decision making during critical and difficult immediate post-earthquake response actions. Real-time calculation of PSA exceedance and alarm dissemination are enabled with Bighorn, a module included in the Antelope software package that combines real-time spectral monitoring and alarm capabilities with a robust built-in web display server. Examples of response spectra from several M 5 events recorded by the ANZA seismic network in southern California will be presented.

  4. Neural correlates of risk perception during real-life risk communication.

    PubMed

    Schmälzle, Ralf; Häcker, Frank; Renner, Britta; Honey, Christopher J; Schupp, Harald T

    2013-06-19

    During global health crises, such as the recent H1N1 pandemic, the mass media provide the public with timely information regarding risk. To obtain new insights into how these messages are received, we measured neural data while participants, who differed in their preexisting H1N1 risk perceptions, viewed a TV report about H1N1. Intersubject correlation (ISC) of neural time courses was used to assess how similarly the brains of viewers responded to the TV report. We found enhanced intersubject correlations among viewers with high-risk perception in the anterior cingulate, a region which classical fMRI studies associated with the appraisal of threatening information. By contrast, neural coupling in sensory-perceptual regions was similar for the high and low H1N1-risk perception groups. These results demonstrate a novel methodology for understanding how real-life health messages are processed in the human brain, with particular emphasis on the role of emotion and differences in risk perceptions.

  5. Neural Correlates of Risk Perception during Real-Life Risk Communication

    PubMed Central

    Häcker, Frank; Renner, Britta; Honey, Christopher J.; Schupp, Harald T.

    2013-01-01

    During global health crises, such as the recent H1N1 pandemic, the mass media provide the public with timely information regarding risk. To obtain new insights into how these messages are received, we measured neural data while participants, who differed in their preexisting H1N1 risk perceptions, viewed a TV report about H1N1. Intersubject correlation (ISC) of neural time courses was used to assess how similarly the brains of viewers responded to the TV report. We found enhanced intersubject correlations among viewers with high-risk perception in the anterior cingulate, a region which classical fMRI studies associated with the appraisal of threatening information. By contrast, neural coupling in sensory-perceptual regions was similar for the high and low H1N1-risk perception groups. These results demonstrate a novel methodology for understanding how real-life health messages are processed in the human brain, with particular emphasis on the role of emotion and differences in risk perceptions. PMID:23785147

  6. Augmented Reality Technology Using Microsoft HoloLens in Anatomic Pathology.

    PubMed

    Hanna, Matthew G; Ahmed, Ishtiaque; Nine, Jeffrey; Prajapati, Shyam; Pantanowitz, Liron

    2018-05-01

    Context Augmented reality (AR) devices such as the Microsoft HoloLens have not been well used in the medical field. Objective To test the HoloLens for clinical and nonclinical applications in pathology. Design A Microsoft HoloLens was tested for virtual annotation during autopsy, viewing 3D gross and microscopic pathology specimens, navigating whole slide images, telepathology, as well as real-time pathology-radiology correlation. Results Pathology residents performing an autopsy wearing the HoloLens were remotely instructed with real-time diagrams, annotations, and voice instruction. 3D-scanned gross pathology specimens could be viewed as holograms and easily manipulated. Telepathology was supported during gross examination and at the time of intraoperative consultation, allowing users to remotely access a pathologist for guidance and to virtually annotate areas of interest on specimens in real-time. The HoloLens permitted radiographs to be coregistered on gross specimens and thereby enhanced locating important pathologic findings. The HoloLens also allowed easy viewing and navigation of whole slide images, using an AR workstation, including multiple coregistered tissue sections facilitating volumetric pathology evaluation. Conclusions The HoloLens is a novel AR tool with multiple clinical and nonclinical applications in pathology. The device was comfortable to wear, easy to use, provided sufficient computing power, and supported high-resolution imaging. It was useful for autopsy, gross and microscopic examination, and ideally suited for digital pathology. Unique applications include remote supervision and annotation, 3D image viewing and manipulation, telepathology in a mixed-reality environment, and real-time pathology-radiology correlation.

  7. Optical Sensor for real-time Monitoring of CO(2) Laser Welding Process.

    PubMed

    Ancona, A; Spagnolo, V; Lugarà, P M; Ferrara, M

    2001-11-20

    An optical sensor for real-time monitoring of laser welding based on a spectroscopic study of the optical emission of plasma plumes has been developed. The welding plasma's electron temperature was contemporarily monitored for three of the chemical species that constitute the plasma plume by use of related emission lines. The evolution of electron temperature was recorded and analyzed during several welding procedures carried out under various operating conditions. A clear correlation between the mean value and the standard deviation of the plasma's electron temperature and the quality of the welded joint has been found. We used this information to find optimal welding parameters and for real-time detection of weld defects such as crater formation, lack of penetration, weld disruptions, and seam oxidation.

  8. Benchmarking real-time RGBD odometry for light-duty UAVs

    NASA Astrophysics Data System (ADS)

    Willis, Andrew R.; Sahawneh, Laith R.; Brink, Kevin M.

    2016-06-01

    This article describes the theoretical and implementation challenges associated with generating 3D odometry estimates (delta-pose) from RGBD sensor data in real-time to facilitate navigation in cluttered indoor environments. The underlying odometry algorithm applies to general 6DoF motion; however, the computational platforms, trajectories, and scene content are motivated by their intended use on indoor, light-duty UAVs. Discussion outlines the overall software pipeline for sensor processing and details how algorithm choices for the underlying feature detection and correspondence computation impact the real-time performance and accuracy of the estimated odometry and associated covariance. This article also explores the consistency of odometry covariance estimates and the correlation between successive odometry estimates. The analysis is intended to provide users information needed to better leverage RGBD odometry within the constraints of their systems.

  9. Comparison of two quantitative fit-test methods using N95 filtering facepiece respirators.

    PubMed

    Sietsema, Margaret; Brosseau, Lisa M

    2016-08-01

    Current regulations require annual fit testing before an employee can wear a respirator during work activities. The goal of this research is to determine whether respirator fit measured with two TSI Portacount instruments simultaneously sampling ambient particle concentrations inside and outside of the respirator facepiece is similar to fit measured during an ambient aerosol condensation nuclei counter quantitative fit test. Sixteen subjects (ten female; six male) were recruited for a range of facial sizes. Each subject donned an N95 filtering facepiece respirator, completed two fit tests in random order (ambient aerosol condensation nuclei counter quantitative fit test and two-instrument real-time fit test) without removing or adjusting the respirator between tests. Fit tests were compared using Spearman's rank correlation coefficients. The real-time two-instrument method fit factors were similar to those measured with the single-instrument quantitative fit test. The first four exercises were highly correlated (r > 0.7) between the two protocols. Respirator fit was altered during the talking or grimace exercise, both of which involve facial movements that could dislodge the facepiece. Our analyses suggest that the new real-time two-instrument methodology can be used in future studies to evaluate fit before and during work activities.

  10. New multiplex real-time PCR approach to detect gene mutations for spinal muscular atrophy.

    PubMed

    Liu, Zhidai; Zhang, Penghui; He, Xiaoyan; Liu, Shan; Tang, Shi; Zhang, Rong; Wang, Xinbin; Tan, Junjie; Peng, Bin; Jiang, Li; Hong, Siqi; Zou, Lin

    2016-08-17

    Spinal muscular atrophy (SMA) is the most common autosomal recessive disease in children, and the diagnosis is complicated and difficult, especially at early stage. Early diagnosis of SMA is able to improve the outcome of SMA patients. In our study, Real-time PCR was developed to measure the gene mutation or deletion of key genes for SMA and to further analyse genotype-phenotype correlation. The multiple real-time PCR for detecting the mutations of survival of motor neuron (SMN), apoptosis inhibitory protein (NAIP) and general transcription factor IIH, polypeptide 2 gene (GTF2H2) was established and confirmed by DNA sequencing and multiplex ligation-dependent probe amplification (MLPA). The diagnosis and prognosis of 141 hospitalized children, 100 normal children and further 2000 cases of dry blood spot (DBS) samples were analysed by this multiple real-time PCR. The multiple real-time PCR was established and the accuracy of it to detect the mutations of SMN, NAIP and GTF2H2 was at least 98.8 % comparing with DNA sequencing and MLPA. Among 141 limb movement disorders children, 75 cases were SMA. 71 cases of SMA (94.67 %) were with SMN c.840 mutation, 9 cases (12 %) with NAIP deletion and 3 cases (4 %) with GTF2H2 deletion. The multiple real-time PCR was able to diagnose and predict the prognosis of SMA patients. Simultaneously, the real-time PCR was applied to detect trace DNA from DBS and able to make an early diagnosis of SMA. The clinical and molecular characteristics of SMA in Southwest of China were presented. Our work provides a novel way for detecting SMA in children by using real-time PCR and the potential usage in newborn screening for early diagnosis of SMA.

  11. Haystack Observatory VLBI Correlator

    NASA Technical Reports Server (NTRS)

    Titus, Mike; Cappallo, Roger; Corey, Brian; Dudevoir, Kevin; Niell, Arthur; Whitney, Alan

    2013-01-01

    This report summarizes the activities of the Haystack Correlator during 2012. Highlights include finding a solution to the DiFX InfiniBand timeout problem and other DiFX software development, conducting a DBE comparison test following the First International VLBI Technology Workshop, conducting a Mark IV and DiFX correlator comparison, more broadband delay experiments, more u- VLBI Galactic Center observations, and conversion of RDV session processing to the Mark IV/HOPS path. Non-real-time e-VLBI transfers and engineering support of other correlators continued.

  12. Using photographs to study animal social cognition and behaviour: Do capuchins' responses to photos reflect reality?

    PubMed

    Morton, F Blake; Brosnan, Sarah F; Prétôt, Laurent; Buchanan-Smith, Hannah M; O'Sullivan, Eoin; Stocker, Martina; D'Mello, Daniel; Wilson, Vanessa A D

    2016-03-01

    Behavioural responses to photos are often used to infer what animals understand about their social environment, but are rarely validated against the same stimuli in real life. If subjects' responses to photos do not reflect responses to the same live stimuli, it is difficult to conclude what happens in reality based on photo responses alone. We compared capuchins' responses to photos versus live stimuli in an identical scenario within research cubicles. Subjects had the opportunity to approach food placed in front of an alpha group member and, in a separate condition, photos depicting the same individual. Subjects' latencies to approach food when placed in front of the real alpha negatively correlated with time subjects spent in close proximity to the alpha in their main enclosure. We therefore predicted subjects' latencies to approach food in the presence of photos would positively correlate with their latencies to approach food in the presence of the real alpha inside the cubicles, but negatively correlate with time they spent in proximity to the alpha in their enclosure. Neither prediction was supported. While not necessarily surprising, we explain why these results should be an important reminder that care is needed when interpreting results from photo studies. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Comparative Evaluation of Three Nucleic Acid-Based Assays for BK Virus Quantification

    PubMed Central

    Descamps, Veronique; Martin, Elodie; Morel, Virginie; François, Catherine; Helle, François; Duverlie, Gilles; Castelain, Sandrine

    2015-01-01

    With the growing importance of BK virus (BKV), effective and efficient screening for BKV replication in plasma and urine samples is very important for monitoring renal transplant and hematopoietic stem cell transplant recipients, who are at increased risk of BKV-associated diseases. However, recent assays proposed by many manufacturers have not been tested, and the available tests have not been standardized. The aim of the present study was to evaluate and compare the performances of three commercially available kits, R-gene, GeneProof, and RealStar, on plasma and urine specimens from patients infected with various genotypes and to determine the correlations with the results from a reference laboratory. A qualitatively excellent global agreement (96.8%) was obtained. RealStar PCR tended to give a higher sensitivity, especially for subtype Ib1 samples. Comparison of 30 plasma samples and 53 urine samples showed a good agreement between the three assays, with Spearman's Rho correlation coefficient values falling between 0.92 and 0.98 (P < 0.001). Moreover, a perfect correlation was obtained for comparison of the assay performances with the AcroMetrix BKV panel (P < 0.001 for all comparisons). According to Bland-Altman analysis, more than 95% (240/249 comparisons) of sample comparisons were situated in the range of the mean ± 2 standard deviations (SD). The greatest variability between assays was observed for 10.2% of subtype Ib2 samples, with differences of >1 log10 copies/ml. In conclusion, this study demonstrated the reliable and comparable performances of the R-gene, GeneProof, and RealStar real-time PCR systems for quantification of BKV in urine and plasma samples. All three real-time PCR assays are appropriate for screening of BKV replication in patients. PMID:26424842

  14. Visualisation and quantitative analysis of the rodent malaria liver stage by real time imaging.

    PubMed

    Ploemen, Ivo H J; Prudêncio, Miguel; Douradinha, Bruno G; Ramesar, Jai; Fonager, Jannik; van Gemert, Geert-Jan; Luty, Adrian J F; Hermsen, Cornelus C; Sauerwein, Robert W; Baptista, Fernanda G; Mota, Maria M; Waters, Andrew P; Que, Ivo; Lowik, Clemens W G M; Khan, Shahid M; Janse, Chris J; Franke-Fayard, Blandine M D

    2009-11-18

    The quantitative analysis of Plasmodium development in the liver in laboratory animals in cultured cells is hampered by low parasite infection rates and the complicated methods required to monitor intracellular development. As a consequence, this important phase of the parasite's life cycle has been poorly studied compared to blood stages, for example in screening anti-malarial drugs. Here we report the use of a transgenic P. berghei parasite, PbGFP-Luc(con), expressing the bioluminescent reporter protein luciferase to visualize and quantify parasite development in liver cells both in culture and in live mice using real-time luminescence imaging. The reporter-parasite based quantification in cultured hepatocytes by real-time imaging or using a microplate reader correlates very well with established quantitative RT-PCR methods. For the first time the liver stage of Plasmodium is visualized in whole bodies of live mice and we were able to discriminate as few as 1-5 infected hepatocytes per liver in mice using 2D-imaging and to identify individual infected hepatocytes by 3D-imaging. The analysis of liver infections by whole body imaging shows a good correlation with quantitative RT-PCR analysis of extracted livers. The luminescence-based analysis of the effects of various drugs on in vitro hepatocyte infection shows that this method can effectively be used for in vitro screening of compounds targeting Plasmodium liver stages. Furthermore, by analysing the effect of primaquine and tafenoquine in vivo we demonstrate the applicability of real time imaging to assess parasite drug sensitivity in the liver. The simplicity and speed of quantitative analysis of liver-stage development by real-time imaging compared to the PCR methodologies, as well as the possibility to analyse liver development in live mice without surgery, opens up new possibilities for research on Plasmodium liver infections and for validating the effect of drugs and vaccines on the liver stage of Plasmodium.

  15. Visualisation and Quantitative Analysis of the Rodent Malaria Liver Stage by Real Time Imaging

    PubMed Central

    Douradinha, Bruno G.; Ramesar, Jai; Fonager, Jannik; van Gemert, Geert-Jan; Luty, Adrian J. F.; Hermsen, Cornelus C.; Sauerwein, Robert W.; Baptista, Fernanda G.; Mota, Maria M.; Waters, Andrew P.; Que, Ivo; Lowik, Clemens W. G. M.; Khan, Shahid M.; Janse, Chris J.; Franke-Fayard, Blandine M. D.

    2009-01-01

    The quantitative analysis of Plasmodium development in the liver in laboratory animals in cultured cells is hampered by low parasite infection rates and the complicated methods required to monitor intracellular development. As a consequence, this important phase of the parasite's life cycle has been poorly studied compared to blood stages, for example in screening anti-malarial drugs. Here we report the use of a transgenic P. berghei parasite, PbGFP-Luccon, expressing the bioluminescent reporter protein luciferase to visualize and quantify parasite development in liver cells both in culture and in live mice using real-time luminescence imaging. The reporter-parasite based quantification in cultured hepatocytes by real-time imaging or using a microplate reader correlates very well with established quantitative RT-PCR methods. For the first time the liver stage of Plasmodium is visualized in whole bodies of live mice and we were able to discriminate as few as 1–5 infected hepatocytes per liver in mice using 2D-imaging and to identify individual infected hepatocytes by 3D-imaging. The analysis of liver infections by whole body imaging shows a good correlation with quantitative RT-PCR analysis of extracted livers. The luminescence-based analysis of the effects of various drugs on in vitro hepatocyte infection shows that this method can effectively be used for in vitro screening of compounds targeting Plasmodium liver stages. Furthermore, by analysing the effect of primaquine and tafenoquine in vivo we demonstrate the applicability of real time imaging to assess parasite drug sensitivity in the liver. The simplicity and speed of quantitative analysis of liver-stage development by real-time imaging compared to the PCR methodologies, as well as the possibility to analyse liver development in live mice without surgery, opens up new possibilities for research on Plasmodium liver infections and for validating the effect of drugs and vaccines on the liver stage of Plasmodium. PMID:19924309

  16. A demonstration of real-time connected element interferometry for spacecraft navigation

    NASA Technical Reports Server (NTRS)

    Edwards, C.; Rogstad, D.; Fort, D.; White, L.; Iijima, B.

    1992-01-01

    Connected element interferometry is a technique of observing a celestial radio source at two spatially separated antennas, and then interfering the received signals to extract the relative phase of the signal at the two antennas. The high precision of the resulting phase delay data type can provide an accurate determination of the angular position of the radio source relative to the baseline vector between the two stations. A connected element interferometer on a 21-km baseline between two antennas at the Deep Space Network's Goldstone, CA tracking complex is developed. Fiber optic links are used to transmit the data at 112 Mbit/sec to a common site for processing. A real-time correlator to process these data in real-time is implemented. The architecture of the system is described, and observational data is presented to characterize the potential performance of such a system. The real-time processing capability offers potential advantages in terms of increased reliability and improved delivery of navigational data for time-critical operations. Angular accuracies of 50-100 nrad are achievable on this baseline.

  17. The goldstone real-time connected element interferometer

    NASA Technical Reports Server (NTRS)

    Edwards, C., Jr.; Rogstad, D.; Fort, D.; White, L.; Iijima, B.

    1992-01-01

    Connected element interferometry (CEI) is a technique of observing a celestial radio source at two spatially separated antennas and then interfering the received signals to extract the relative phase of the signal at the two antennas. The high precision of the resulting phase delay data type can provide an accurate determination of the angular position of the radio source relative to the baseline vector between the two stations. This article describes a recently developed connected element interferometer on a 21-km baseline between two antennas at the Deep Space Network's Goldstone, California, tracking complex. Fiber-optic links are used to transmit the data to a common site for processing. The system incorporates a real-time correlator to process these data in real time. The architecture of the system is described, and observational data are presented to characterize the potential performance of such a system. The real-time processing capability offers potential advantages in terms of increased reliability and improved delivery of navigational data for time-critical operations. Angular accuracies of 50-100 nrad are achievable on this baseline.

  18. Network-based real-time radiation monitoring system in Synchrotron Radiation Research Center.

    PubMed

    Sheu, R J; Wang, J P; Chen, C R; Liu, J; Chang, F D; Jiang, S H

    2003-10-01

    The real-time radiation monitoring system (RMS) in the Synchrotron Radiation Research Center (SRRC) has been upgraded significantly during the past years. The new framework of the RMS is built on the popular network technology, including Ethernet hardware connections and Web-based software interfaces. It features virtually no distance limitations, flexible and scalable equipment connections, faster response time, remote diagnosis, easy maintenance, as well as many graphic user interface software tools. This paper briefly describes the radiation environment in SRRC and presents the system configuration, basic functions, and some operational results of this real-time RMS. Besides the control of radiation exposures, it has been demonstrated that a variety of valuable information or correlations could be extracted from the measured radiation levels delivered by the RMS, including the changes of operating conditions, beam loss pattern, radiation skyshine, and so on. The real-time RMS can be conveniently accessed either using the dedicated client program or World Wide Web interface. The address of the Web site is http:// www-rms.srrc.gov.tw.

  19. Direct detection by real-time PCR of ftsI gene mutations affecting MICs of β-lactam agents for Haemophilus influenzae isolates from meningitis.

    PubMed

    Kishii, Kozue; Morozumi, Miyuki; Chiba, Naoko; Ono, Akiko; Ubukata, Kimiko

    2011-10-01

    One resistance mechanism of Haemophilus influenzae to ampicillin involves decreased affinity of penicillin-binding protein (PBP) 3 for β-lactam antibiotics reflecting amino acid substitutions in PBP3 encoded by the ftsI gene. Three amino acid substitutions, Ser385Thr, Arg517His, and Asn526Lys, are especially responsible for β-lactam resistance. We constructed a new real-time polymerase chain reaction (PCR) to directly detect these substitutions in addition to 16S ribosomal RNA (rRNA), cap, and bla(TEM) genes. Our real-time PCR was evaluated using 206 clinical H. influenzae strains isolated from pediatric patients with meningitis. Relative sensitivities and specificities of real-time PCR were 90.5-100% and 96.3-100% for all resistance classes compared with our previously reported conventional PCR. In addition, real-time PCR shortened time required from 3 h by conventional PCR to 1.5 h. When correlations between combinations of amino acid substitutions in the ftsI gene detected by real-time PCR and minimum inhibitory concentrations (MICs) of β-lactam antibiotics were evaluated, MIC(90)s of ampicillin for β-lactamase-nonproducing ampicillin-intermediate-resistant strains with Asn526Lys, β-lactamase-nonproducing, ampicillin-resistant strains with Ser385Thr, and β-lactamase-nonproducing ampicillin-resistant strains with both Asn526Lys and Ser385Thr, respectively, were two, four, and eight times higher than those for sensitive strains. Similarly, MIC(90)s of cephalosporins for these strains, respectively, were two, 16-32, and 16-32 times higher than those for sensitive strains. Thus, real-time PCR can guide antibiotic use.

  20. Sustained Reduction of Ventilator-Associated Pneumonia Rates Using Real-Time Course Correction With a Ventilator Bundle Compliance Dashboard.

    PubMed

    Talbot, Thomas R; Carr, Devin; Parmley, C Lee; Martin, Barbara J; Gray, Barbara; Ambrose, Anna; Starmer, Jack

    2015-11-01

    The effectiveness of practice bundles on reducing ventilator-associated pneumonia (VAP) has been questioned. To implement a comprehensive program that included a real-time bundle compliance dashboard to improve compliance and reduce ventilator-associated complications. DESIGN Before-and-after quasi-experimental study with interrupted time-series analysis. SETTING Academic medical center. In 2007 a comprehensive institutional ventilator bundle program was developed. To assess bundle compliance and stimulate instant course correction of noncompliant parameters, a real-time computerized dashboard was developed. Program impact in 6 adult intensive care units (ICUs) was assessed. Bundle compliance was noted as an overall cumulative bundle adherence assessment, reflecting the percentage of time all elements were concurrently in compliance for all patients. The VAP rate in all ICUs combined decreased from 19.5 to 9.2 VAPs per 1,000 ventilator-days following program implementation (P<.001). Bundle compliance significantly increased (Z100 score of 23% in August 2007 to 83% in June 2011 [P<.001]). The implementation resulted in a significant monthly decrease in the overall ICU VAP rate of 3.28/1,000 ventilator-days (95% CI, 2.64-3.92/1,000 ventilator-days). Following the intervention, the VAP rate decreased significantly at a rate of 0.20/1,000 ventilator-days per month (95% CI, 0.14-0.30/1,000 ventilator-days per month). Among all adult ICUs combined, improved bundle compliance was moderately correlated with monthly VAP rate reductions (Pearson correlation coefficient, -0.32). A prevention program using a real-time bundle adherence dashboard was associated with significant sustained decreases in VAP rates and an increase in bundle compliance among adult ICU patients.

  1. MO-FG-BRD-01: Real-Time Imaging and Tracking Techniques for Intrafractional Motion Management: Introduction and KV Tracking

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fahimian, B.

    2015-06-15

    Intrafraction target motion is a prominent complicating factor in the accurate targeting of radiation within the body. Methods compensating for target motion during treatment, such as gating and dynamic tumor tracking, depend on the delineation of target location as a function of time during delivery. A variety of techniques for target localization have been explored and are under active development; these include beam-level imaging of radio-opaque fiducials, fiducial-less tracking of anatomical landmarks, tracking of electromagnetic transponders, optical imaging of correlated surrogates, and volumetric imaging within treatment delivery. The Joint Imaging and Therapy Symposium will provide an overview of the techniquesmore » for real-time imaging and tracking, with special focus on emerging modes of implementation across different modalities. In particular, the symposium will explore developments in 1) Beam-level kilovoltage X-ray imaging techniques, 2) EPID-based megavoltage X-ray tracking, 3) Dynamic tracking using electromagnetic transponders, and 4) MRI-based soft-tissue tracking during radiation delivery. Learning Objectives: Understand the fundamentals of real-time imaging and tracking techniques Learn about emerging techniques in the field of real-time tracking Distinguish between the advantages and disadvantages of different tracking modalities Understand the role of real-time tracking techniques within the clinical delivery work-flow.« less

  2. MO-FG-BRD-04: Real-Time Imaging and Tracking Techniques for Intrafractional Motion Management: MR Tracking

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Low, D.

    2015-06-15

    Intrafraction target motion is a prominent complicating factor in the accurate targeting of radiation within the body. Methods compensating for target motion during treatment, such as gating and dynamic tumor tracking, depend on the delineation of target location as a function of time during delivery. A variety of techniques for target localization have been explored and are under active development; these include beam-level imaging of radio-opaque fiducials, fiducial-less tracking of anatomical landmarks, tracking of electromagnetic transponders, optical imaging of correlated surrogates, and volumetric imaging within treatment delivery. The Joint Imaging and Therapy Symposium will provide an overview of the techniquesmore » for real-time imaging and tracking, with special focus on emerging modes of implementation across different modalities. In particular, the symposium will explore developments in 1) Beam-level kilovoltage X-ray imaging techniques, 2) EPID-based megavoltage X-ray tracking, 3) Dynamic tracking using electromagnetic transponders, and 4) MRI-based soft-tissue tracking during radiation delivery. Learning Objectives: Understand the fundamentals of real-time imaging and tracking techniques Learn about emerging techniques in the field of real-time tracking Distinguish between the advantages and disadvantages of different tracking modalities Understand the role of real-time tracking techniques within the clinical delivery work-flow.« less

  3. MO-FG-BRD-02: Real-Time Imaging and Tracking Techniques for Intrafractional Motion Management: MV Tracking

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berbeco, R.

    2015-06-15

    Intrafraction target motion is a prominent complicating factor in the accurate targeting of radiation within the body. Methods compensating for target motion during treatment, such as gating and dynamic tumor tracking, depend on the delineation of target location as a function of time during delivery. A variety of techniques for target localization have been explored and are under active development; these include beam-level imaging of radio-opaque fiducials, fiducial-less tracking of anatomical landmarks, tracking of electromagnetic transponders, optical imaging of correlated surrogates, and volumetric imaging within treatment delivery. The Joint Imaging and Therapy Symposium will provide an overview of the techniquesmore » for real-time imaging and tracking, with special focus on emerging modes of implementation across different modalities. In particular, the symposium will explore developments in 1) Beam-level kilovoltage X-ray imaging techniques, 2) EPID-based megavoltage X-ray tracking, 3) Dynamic tracking using electromagnetic transponders, and 4) MRI-based soft-tissue tracking during radiation delivery. Learning Objectives: Understand the fundamentals of real-time imaging and tracking techniques Learn about emerging techniques in the field of real-time tracking Distinguish between the advantages and disadvantages of different tracking modalities Understand the role of real-time tracking techniques within the clinical delivery work-flow.« less

  4. MO-FG-BRD-03: Real-Time Imaging and Tracking Techniques for Intrafractional Motion Management: EM Tracking

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Keall, P.

    2015-06-15

    Intrafraction target motion is a prominent complicating factor in the accurate targeting of radiation within the body. Methods compensating for target motion during treatment, such as gating and dynamic tumor tracking, depend on the delineation of target location as a function of time during delivery. A variety of techniques for target localization have been explored and are under active development; these include beam-level imaging of radio-opaque fiducials, fiducial-less tracking of anatomical landmarks, tracking of electromagnetic transponders, optical imaging of correlated surrogates, and volumetric imaging within treatment delivery. The Joint Imaging and Therapy Symposium will provide an overview of the techniquesmore » for real-time imaging and tracking, with special focus on emerging modes of implementation across different modalities. In particular, the symposium will explore developments in 1) Beam-level kilovoltage X-ray imaging techniques, 2) EPID-based megavoltage X-ray tracking, 3) Dynamic tracking using electromagnetic transponders, and 4) MRI-based soft-tissue tracking during radiation delivery. Learning Objectives: Understand the fundamentals of real-time imaging and tracking techniques Learn about emerging techniques in the field of real-time tracking Distinguish between the advantages and disadvantages of different tracking modalities Understand the role of real-time tracking techniques within the clinical delivery work-flow.« less

  5. MO-FG-BRD-00: Real-Time Imaging and Tracking Techniques for Intrafractional Motion Management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    2015-06-15

    Intrafraction target motion is a prominent complicating factor in the accurate targeting of radiation within the body. Methods compensating for target motion during treatment, such as gating and dynamic tumor tracking, depend on the delineation of target location as a function of time during delivery. A variety of techniques for target localization have been explored and are under active development; these include beam-level imaging of radio-opaque fiducials, fiducial-less tracking of anatomical landmarks, tracking of electromagnetic transponders, optical imaging of correlated surrogates, and volumetric imaging within treatment delivery. The Joint Imaging and Therapy Symposium will provide an overview of the techniquesmore » for real-time imaging and tracking, with special focus on emerging modes of implementation across different modalities. In particular, the symposium will explore developments in 1) Beam-level kilovoltage X-ray imaging techniques, 2) EPID-based megavoltage X-ray tracking, 3) Dynamic tracking using electromagnetic transponders, and 4) MRI-based soft-tissue tracking during radiation delivery. Learning Objectives: Understand the fundamentals of real-time imaging and tracking techniques Learn about emerging techniques in the field of real-time tracking Distinguish between the advantages and disadvantages of different tracking modalities Understand the role of real-time tracking techniques within the clinical delivery work-flow.« less

  6. A KST framework for correlation network construction from time series signals

    NASA Astrophysics Data System (ADS)

    Qi, Jin-Peng; Gu, Quan; Zhu, Ying; Zhang, Ping

    2018-04-01

    A KST (Kolmogorov-Smirnov test and T statistic) method is used for construction of a correlation network based on the fluctuation of each time series within the multivariate time signals. In this method, each time series is divided equally into multiple segments, and the maximal data fluctuation in each segment is calculated by a KST change detection procedure. Connections between each time series are derived from the data fluctuation matrix, and are used for construction of the fluctuation correlation network (FCN). The method was tested with synthetic simulations and the result was compared with those from using KS or T only for detection of data fluctuation. The novelty of this study is that the correlation analyses was based on the data fluctuation in each segment of each time series rather than on the original time signals, which would be more meaningful for many real world applications and for analysis of large-scale time signals where prior knowledge is uncertain.

  7. Algorithm for real-time detection of signal patterns using phase synchrony: an application to an electrode array

    NASA Astrophysics Data System (ADS)

    Sadeghi, Saman; MacKay, William A.; van Dam, R. Michael; Thompson, Michael

    2011-02-01

    Real-time analysis of multi-channel spatio-temporal sensor data presents a considerable technical challenge for a number of applications. For example, in brain-computer interfaces, signal patterns originating on a time-dependent basis from an array of electrodes on the scalp (i.e. electroencephalography) must be analyzed in real time to recognize mental states and translate these to commands which control operations in a machine. In this paper we describe a new technique for recognition of spatio-temporal patterns based on performing online discrimination of time-resolved events through the use of correlation of phase dynamics between various channels in a multi-channel system. The algorithm extracts unique sensor signature patterns associated with each event during a training period and ranks importance of sensor pairs in order to distinguish between time-resolved stimuli to which the system may be exposed during real-time operation. We apply the algorithm to electroencephalographic signals obtained from subjects tested in the neurophysiology laboratories at the University of Toronto. The extension of this algorithm for rapid detection of patterns in other sensing applications, including chemical identification via chemical or bio-chemical sensor arrays, is also discussed.

  8. Evaluation of the Aptima(®) HIV-1 Quant Dx assay for HIV-1 RNA viral load detection and quantitation in plasma of HIV-1-infected individuals: A comparison with Abbott RealTime HIV-1 assay.

    PubMed

    Amendola, Alessandra; Pisciotta, Maria; Aleo, Loredana; Ferraioli, Valeria; Angeletti, Claudio; Capobianchi, Maria Rosaria

    2016-09-01

    The Hologic Aptima(®) HIV-1 Quant Dx assay (Aptima HIV) is a real-time transcription-mediated amplification method CE-approved for use in diagnosis and monitoring of HIV-1 infection. The analytical performance of this new assay was compared to the FDA-approved Abbott RealTime HIV-1 (RealTime). The evaluation was performed using 220 clinical plasma samples, the WHO 3rd HIV-1 International Standard, and the QCMD HIV-1 RNA EQA. Concordance on qualitative results, correlation between quantitative results, accuracy, and reproducibility of viral load data were analyzed. The ability to measure HIV-1 subtypes was assessed on the second WHO International Reference Preparation Panel for HIV-1 Subtypes. With clinical samples, inter-assay agreement for qualitative results was high (91.8%) with Cohen's kappa statistic equal to 0.836. For samples with quantitative results in both assays (n = 93), Lin's concordance correlation coefficient was 0.980 (P < 0.0001) and mean differences of measurement, conducted according to Bland-Altman method, was low (0.115 log10  copies/ml). The Aptima HIV quantified the WHO 3rd HIV-1 International Standard diluted from 2000 to 31 cp/ml (5,700-88 IU/ml) at expected values with excellent linearity (R(2)  > 0.970) and showed higher sensitivity compared to RealTime being able to detect HIV-1 RNA in 10 out of 10 replicates containing down to 7 cp/ml (20 IU/ml). Reproducibility was very high, even at low HIV-1 RNA values. The Aptima HIV was able to detect and accurately quantify all the main HIV-1 subtypes in both reference panels and clinical samples. Besides excellent performance, Aptima HIV shows full automation, ease of use, and improved workflow compared to RealTime. J. Med. Virol. 88:1535-1544, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  9. Real-Time Tracking of Selective Auditory Attention From M/EEG: A Bayesian Filtering Approach

    PubMed Central

    Miran, Sina; Akram, Sahar; Sheikhattar, Alireza; Simon, Jonathan Z.; Zhang, Tao; Babadi, Behtash

    2018-01-01

    Humans are able to identify and track a target speaker amid a cacophony of acoustic interference, an ability which is often referred to as the cocktail party phenomenon. Results from several decades of studying this phenomenon have culminated in recent years in various promising attempts to decode the attentional state of a listener in a competing-speaker environment from non-invasive neuroimaging recordings such as magnetoencephalography (MEG) and electroencephalography (EEG). To this end, most existing approaches compute correlation-based measures by either regressing the features of each speech stream to the M/EEG channels (the decoding approach) or vice versa (the encoding approach). To produce robust results, these procedures require multiple trials for training purposes. Also, their decoding accuracy drops significantly when operating at high temporal resolutions. Thus, they are not well-suited for emerging real-time applications such as smart hearing aid devices or brain-computer interface systems, where training data might be limited and high temporal resolutions are desired. In this paper, we close this gap by developing an algorithmic pipeline for real-time decoding of the attentional state. Our proposed framework consists of three main modules: (1) Real-time and robust estimation of encoding or decoding coefficients, achieved by sparse adaptive filtering, (2) Extracting reliable markers of the attentional state, and thereby generalizing the widely-used correlation-based measures thereof, and (3) Devising a near real-time state-space estimator that translates the noisy and variable attention markers to robust and statistically interpretable estimates of the attentional state with minimal delay. Our proposed algorithms integrate various techniques including forgetting factor-based adaptive filtering, ℓ1-regularization, forward-backward splitting algorithms, fixed-lag smoothing, and Expectation Maximization. We validate the performance of our proposed framework using comprehensive simulations as well as application to experimentally acquired M/EEG data. Our results reveal that the proposed real-time algorithms perform nearly as accurately as the existing state-of-the-art offline techniques, while providing a significant degree of adaptivity, statistical robustness, and computational savings. PMID:29765298

  10. Real-Time Tracking of Selective Auditory Attention From M/EEG: A Bayesian Filtering Approach.

    PubMed

    Miran, Sina; Akram, Sahar; Sheikhattar, Alireza; Simon, Jonathan Z; Zhang, Tao; Babadi, Behtash

    2018-01-01

    Humans are able to identify and track a target speaker amid a cacophony of acoustic interference, an ability which is often referred to as the cocktail party phenomenon. Results from several decades of studying this phenomenon have culminated in recent years in various promising attempts to decode the attentional state of a listener in a competing-speaker environment from non-invasive neuroimaging recordings such as magnetoencephalography (MEG) and electroencephalography (EEG). To this end, most existing approaches compute correlation-based measures by either regressing the features of each speech stream to the M/EEG channels (the decoding approach) or vice versa (the encoding approach). To produce robust results, these procedures require multiple trials for training purposes. Also, their decoding accuracy drops significantly when operating at high temporal resolutions. Thus, they are not well-suited for emerging real-time applications such as smart hearing aid devices or brain-computer interface systems, where training data might be limited and high temporal resolutions are desired. In this paper, we close this gap by developing an algorithmic pipeline for real-time decoding of the attentional state. Our proposed framework consists of three main modules: (1) Real-time and robust estimation of encoding or decoding coefficients, achieved by sparse adaptive filtering, (2) Extracting reliable markers of the attentional state, and thereby generalizing the widely-used correlation-based measures thereof, and (3) Devising a near real-time state-space estimator that translates the noisy and variable attention markers to robust and statistically interpretable estimates of the attentional state with minimal delay. Our proposed algorithms integrate various techniques including forgetting factor-based adaptive filtering, ℓ 1 -regularization, forward-backward splitting algorithms, fixed-lag smoothing, and Expectation Maximization. We validate the performance of our proposed framework using comprehensive simulations as well as application to experimentally acquired M/EEG data. Our results reveal that the proposed real-time algorithms perform nearly as accurately as the existing state-of-the-art offline techniques, while providing a significant degree of adaptivity, statistical robustness, and computational savings.

  11. Traffic Predictive Control: Case Study and Evaluation

    DOT National Transportation Integrated Search

    2017-06-26

    This project developed a quantile regression method for predicting future traffic flow at a signalized intersection by combining both historical and real-time data. The algorithm exploits nonlinear correlations in historical measurements and efficien...

  12. General ultrafast pulse measurement using the cross-correlation single-shot sonogram technique.

    PubMed

    Reid, Derryck T; Garduno-Mejia, Jesus

    2004-03-15

    The cross-correlation single-shot sonogram technique offers exact pulse measurement and real-time pulse monitoring via an intuitive time-frequency trace whose shape and orientation directly indicate the spectral chirp of an ultrashort laser pulse. We demonstrate an algorithm that solves a fundamental limitation of the cross-correlation sonogram method, namely, that the time-gating operation is implemented using a replica of the measured pulse rather than the ideal delta-function-like pulse. Using a modified principal-components generalized projections algorithm, we experimentally show accurate pulse retrieval of an asymmetric double pulse, a case that is prone to systematic error when one is using the original sonogram retrieval algorithm.

  13. Combined multi-distance frequency domain and diffuse correlation spectroscopy system with simultaneous data acquisition and real-time analysis.

    PubMed

    Carp, Stefan A; Farzam, Parisa; Redes, Norin; Hueber, Dennis M; Franceschini, Maria Angela

    2017-09-01

    Frequency domain near infrared spectroscopy (FD-NIRS) and diffuse correlation spectroscopy (DCS) have emerged as synergistic techniques for the non-invasive assessment of tissue health. Combining FD-NIRS oximetry with DCS measures of blood flow, the tissue oxygen metabolic rate can be quantified, a parameter more closely linked to underlying physiology and pathology than either NIRS or DCS estimates alone. Here we describe the first commercially available integrated instrument, called the "MetaOx", designed to enable simultaneous FD-NIRS and DCS measurements at rates of 10 + Hz, and offering real-time data evaluation. We show simultaneously acquired characterization data demonstrating performance equivalent to individual devices and sample in vivo measurements of pulsation resolved blood flow, forearm occlusion hemodynamic changes and muscle oxygen metabolic rate monitoring during stationary bike exercise.

  14. Combined multi-distance frequency domain and diffuse correlation spectroscopy system with simultaneous data acquisition and real-time analysis

    PubMed Central

    Carp, Stefan A.; Farzam, Parisa; Redes, Norin; Hueber, Dennis M.; Franceschini, Maria Angela

    2017-01-01

    Frequency domain near infrared spectroscopy (FD-NIRS) and diffuse correlation spectroscopy (DCS) have emerged as synergistic techniques for the non-invasive assessment of tissue health. Combining FD-NIRS oximetry with DCS measures of blood flow, the tissue oxygen metabolic rate can be quantified, a parameter more closely linked to underlying physiology and pathology than either NIRS or DCS estimates alone. Here we describe the first commercially available integrated instrument, called the “MetaOx”, designed to enable simultaneous FD-NIRS and DCS measurements at rates of 10 + Hz, and offering real-time data evaluation. We show simultaneously acquired characterization data demonstrating performance equivalent to individual devices and sample in vivo measurements of pulsation resolved blood flow, forearm occlusion hemodynamic changes and muscle oxygen metabolic rate monitoring during stationary bike exercise. PMID:29026684

  15. Accuracy of indocyanine green pulse spectrophotometry clearance test for liver function prediction in transplanted patients

    PubMed Central

    Hsieh, Chung-Bao; Chen, Chung-Jueng; Chen, Teng-Wei; Yu, Jyh-Cherng; Shen, Kuo-Liang; Chang, Tzu-Ming; Liu, Yao-Chi

    2004-01-01

    AIM: To investigate whether the non-invasive real-time Indocynine green (ICG) clearance is a sensitive index of liver viability in patients before, during, and after liver transplantation. METHODS: Thirteen patients were studied, two before, three during, and eight following liver transplantation, with two patients suffering acute rejection. The conventional invasive ICG clearance test and ICG pulse spectrophotometry non-invasive real-time ICG clearance test were performed simultaneously. Using linear regression analysis we tested the correlation between these two methods. The transplantation condition of these patients and serum total bilirubin (T. Bil), alanine aminotransferase (ALT), and platelet count were also evaluated. RESULTS: The correlation between these two methods was excellent (r2 = 0.977). CONCLUSION: ICG pulse spectrophotometry clearance is a quick, non-invasive, and reliable liver function test in transplantation patients. PMID:15285026

  16. Quantitative assessment of tumor angiogenesis using real-time motion-compensated contrast-enhanced ultrasound imaging

    PubMed Central

    Pysz, Marybeth A.; Guracar, Ismayil; Foygel, Kira; Tian, Lu; Willmann, Jürgen K.

    2015-01-01

    Purpose To develop and test a real-time motion compensation algorithm for contrast-enhanced ultrasound imaging of tumor angiogenesis on a clinical ultrasound system. Materials and methods The Administrative Institutional Panel on Laboratory Animal Care approved all experiments. A new motion correction algorithm measuring the sum of absolute differences in pixel displacements within a designated tracking box was implemented in a clinical ultrasound machine. In vivo angiogenesis measurements (expressed as percent contrast area) with and without motion compensated maximum intensity persistence (MIP) ultrasound imaging were analyzed in human colon cancer xenografts (n = 64) in mice. Differences in MIP ultrasound imaging signal with and without motion compensation were compared and correlated with displacements in x- and y-directions. The algorithm was tested in an additional twelve colon cancer xenograft-bearing mice with (n = 6) and without (n = 6) anti-vascular therapy (ASA-404). In vivo MIP percent contrast area measurements were quantitatively correlated with ex vivo microvessel density (MVD) analysis. Results MIP percent contrast area was significantly different (P < 0.001) with and without motion compensation. Differences in percent contrast area correlated significantly (P < 0.001) with x- and y-displacements. MIP percent contrast area measurements were more reproducible with motion compensation (ICC = 0.69) than without (ICC = 0.51) on two consecutive ultrasound scans. Following anti-vascular therapy, motion-compensated MIP percent contrast area significantly (P = 0.03) decreased by 39.4 ± 14.6 % compared to non-treated mice and correlated well with ex vivo MVD analysis (Rho = 0.70; P = 0.05). Conclusion Real-time motion-compensated MIP ultrasound imaging allows reliable and accurate quantification and monitoring of angiogenesis in tumors exposed to breathing-induced motion artifacts. PMID:22535383

  17. Quantitative assessment of tumor angiogenesis using real-time motion-compensated contrast-enhanced ultrasound imaging.

    PubMed

    Pysz, Marybeth A; Guracar, Ismayil; Foygel, Kira; Tian, Lu; Willmann, Jürgen K

    2012-09-01

    To develop and test a real-time motion compensation algorithm for contrast-enhanced ultrasound imaging of tumor angiogenesis on a clinical ultrasound system. The Administrative Institutional Panel on Laboratory Animal Care approved all experiments. A new motion correction algorithm measuring the sum of absolute differences in pixel displacements within a designated tracking box was implemented in a clinical ultrasound machine. In vivo angiogenesis measurements (expressed as percent contrast area) with and without motion compensated maximum intensity persistence (MIP) ultrasound imaging were analyzed in human colon cancer xenografts (n = 64) in mice. Differences in MIP ultrasound imaging signal with and without motion compensation were compared and correlated with displacements in x- and y-directions. The algorithm was tested in an additional twelve colon cancer xenograft-bearing mice with (n = 6) and without (n = 6) anti-vascular therapy (ASA-404). In vivo MIP percent contrast area measurements were quantitatively correlated with ex vivo microvessel density (MVD) analysis. MIP percent contrast area was significantly different (P < 0.001) with and without motion compensation. Differences in percent contrast area correlated significantly (P < 0.001) with x- and y-displacements. MIP percent contrast area measurements were more reproducible with motion compensation (ICC = 0.69) than without (ICC = 0.51) on two consecutive ultrasound scans. Following anti-vascular therapy, motion-compensated MIP percent contrast area significantly (P = 0.03) decreased by 39.4 ± 14.6 % compared to non-treated mice and correlated well with ex vivo MVD analysis (Rho = 0.70; P = 0.05). Real-time motion-compensated MIP ultrasound imaging allows reliable and accurate quantification and monitoring of angiogenesis in tumors exposed to breathing-induced motion artifacts.

  18. Ultra-rapid earth rotation determination with VLBI during CONT11 and CONT14

    NASA Astrophysics Data System (ADS)

    Haas, Rüdiger; Hobiger, Thomas; Kurihara, Shinobu; Hara, Tetsuya

    2015-08-01

    In 2007 the Geospatial Information Authority of Japan (GSI) and the Onsala Space Observatory (OSO) started a collaboration project aiming at determining the earth rotation angle, usually expressed as UT1-UTC, in near real-time. In the beginning of this project dedicated one hour long one-baseline experiments were observed periodically using the VLBI stations Onsala (Sweden) and Tsukuba (Japan). The strategy is that the observed VLBI data are sent in real-time via the international optical fibre backbone to the correlator at Tsukuba where the data are correlated with a software correlator and analyzed in near-real time with the c5++ VLBI data analysis software, thus producing UT1-UTC results with very low latency. The latency between the observation at the stations and the determination of UT1-UTC is on the order of a few minutes, thus we can talk about an ultra-rapid determination of UT1-UTC. An offline version of this strategy was adopted in 2009 for the regular VLBI intensive series INT-2, organized by the International VLBI Service for Geodesy and Astrometry (IVS), that involves Wettzell (Germany) and Tsukuba. Since March 2010 the INT-2 is using real-time e-transfer, too, and since June 2010 also automated analysis. Starting in 2009 the ultra-rapid approach was applied to regular 24 hour long IVS VLBI-sessions that involve Tsukuba and Onsala, so that ultra-rapid UT1-UTC results can be produced already during ongoing VLBI-sessions. This strategy was successfully operated during the 15 days long continuous VLBI campaigns CONT11 and CONT14. In this presentation we give an overview of the ultra-rapid concept, present the results derived during CONT11 and CONT14, and compare these ultra-rapid results to results derived from post-processing

  19. Ultra-rapid earth rotation determination with VLBI during CONT11 and CONT14

    NASA Astrophysics Data System (ADS)

    Haas, Rüdiger; Hobiger, Thomas; Kurihara, Shinobu; Hara, Tetsuya

    2016-04-01

    In 2007 the Geospatial Information Authority of Japan (GSI) and the Onsala Space Observatory (OSO) started a collaboration project aiming at determining the earth rotation angle, usually expressed as UT1-UTC, in near real-time. In the beginning of this project dedicated one hour long one-baseline experiments were observed periodically using the VLBI stations Onsala (Sweden) and Tsukuba (Japan). The strategy is that the observed VLBI data are sent in real-time via the international optical fibre backbone to the correlator at Tsukuba where the data are correlated with a software correlator and analyzed in near-real time with the c5++ VLBI data analysis software, thus producing UT1-UTC results with very low latency. The latency between the observation at the stations and the determination of UT1-UTC is on the order of a few minutes, thus we can talk about an ultra-rapid determination of UT1-UTC. An offline version of this strategy was adopted in 2009 for the regular VLBI intensive series INT-2, organized by the International VLBI Service for Geodesy and Astrometry (IVS), that involves Wettzell (Germany) and Tsukuba. Since March 2010 the INT-2 is using real-time e-transfer, too, and since June 2010 also automated analysis. Starting in 2009 the ultra-rapid approach was applied to regular 24 hour long IVS VLBI-sessions that involve Tsukuba and Onsala, so that ultra-rapid UT1-UTC results can be produced already during ongoing VLBI-sessions. This strategy was successfully operated during the 15 days long continuous VLBI campaigns CONT11 and CONT14. In this presentation we give an overview of the ultra-rapid concept, present the results derived during CONT11 and CONT14, and compare these ultra-rapid results to results derived from post-processing.

  20. [Application of transcription mediated amplification and real-time reverse transcription polymerase chain reaction in detection of human immunodeficiency virus RNA].

    PubMed

    Wu, Daxian; Tao, Shuhui; Liu, Shuiping; Zhou, Jiebin; Tan, Deming; Hou, Zhouhua

    2017-07-28

    To observe the sensitivity of transcription mediated amplification (TMA), and to compare its performance with real-time reverse transcription polymerase chain reaction (real-time RT-PCR) in detecting human immunodeficiency virus RNA (HIV RNA).
 Methods: TMA system was established with TaqMan probes, specific primers, moloney murine leukemia virus (MMLV) reverse transcriptase, T7 RNA polymerase, and reaction substrates. The sensitivity of TMA was evaluated by amplifying a group of 10-fold diluted HIV RNA standards which were transcribed in vitro. A total of 60 plasma of HIV infected patients were measured by TMA and Cobas Amplicor HIV-1 Monitor test to observe the positive rate. The correlation and concordance of the above two technologies were investigated by linear regression and Bland-Altman analysis.
 Results: TMA system was established successfully and HIV RNA transcribed standards at concentration of equal or more than 10 copies/mL could be detected by TMA technology. Among 60 samples of plasma from HIV infected patients, 46 were positively detected and 12 were negatively amplified by both TMA and Cobas reagents; 2 samples were positively tested by Cobas reagent but negatively tested by TMA system. The concordance rate of the two methods was 97.1% and the difference of positive detection rate between the two methods was not statistically significant (P>0.05). Linear regression was used for 46 samples which were positively detected by both TMA and Cobas reagents and showed an excellent correlation between the two reagents (r=0.997, P<0.001). Bland-Altma analysis revealed that the mean different value of HIV RNA levels for denary logarithm was 0.02. Forty-four samples were included in 95% of credibility interval of concordance.
 Conclusion: TMA system has the potential of high sensitivity. TMA and real-time RT-PCR keep an excellent correlation and consistency in detecting HIV RNA.

  1. Diagnosis of invasive fungal infections using real-time PCR assay in paediatric acute leukaemia induction.

    PubMed

    Mandhaniya, Sushil; Iqbal, Sobuhi; Sharawat, Surender Kumar; Xess, Immaculata; Bakhshi, Sameer

    2012-07-01

    Invasive fungal infections (IFI) lead to morbidity and mortality in neutropenic patients and in allogenic stem cell transplantation. Serum-based fungal detection assays have limitation of specificity or sensitivity. Studies on fungal DNA detection using real-time PCR in childhood leukaemia are lacking. The aim of this study was to develop sensitive and specific diagnostic tools for IFI in paediatric acute leukaemia patients using real-time PCR. Of 100 randomised paediatric acute leukaemia patients receiving antifungal prophylaxis with voriconazole/amphotericin B, single peripheral whole blood sample in EDTA was used for Pan-AC real-time PCR assay (detects nine Candida and six Aspergillus species) in patients who failed prophylaxis due to proven, probable, possible or suspected fungal infections. PCR results were retrospectively correlated with clinical profile. Real-time PCR test was positive in 18/29 (62%) patients who failed prophylaxis. The only patient with proven IFI (mucormycosis), real-time PCR assay was negative. Real-time PCR was positive in 2/4 (50%) patients with possible and 16/24 (66.6%) suspected IFI and 5/10 (50%) patients with pneumonia. By applying method A/B, sensitivity and positive predictive value could not be commented due to unproven Aspergillus or Candida infections; specificity and negative predictive values (NPV) were 41% and 100% respectively; by method C (included episodes of possible IFI as true positive), sensitivity, specificity, PPV and NPV were 50%, 36%, 11% and 81% respectively. In those with suspected IFI, 8/24 (33.3%) were PCR negative and unnecessarily received empirical antifungal therapy (EAFT). Real-time PCR is a practical, rapid, non-invasive screening test for excluding IFI in paediatric leukaemia. The high NPV makes real-time PCR a promising tool to use this prior to initiating EAFT in antibiotic-resistant febrile neutropenic patients; this would avoid toxicity, cost and hospitalisation for EAFT (ClinicalTrials.gov identifier:NCT00624143). © 2011 Blackwell Verlag GmbH.

  2. Label-free CMOS bio sensor with on-chip noise reduction scheme for real-time quantitative monitoring of biomolecules.

    PubMed

    Seong-Jin Kim; Euisik Yoon

    2012-06-01

    We present a label-free CMOS field-effect transistor sensing array to detect the surface potential change affected by the negative charge in DNA molecules for real-time monitoring and quantification. The proposed CMOS bio sensor includes a new sensing pixel architecture implemented with correlated double sampling for reducing offset fixed pattern noise and 1/f noise of the sensing devices. We incorporated non-surface binding detection which allows real-time continuous monitoring of DNA concentrations without immobilizing them on the sensing surface. Various concentrations of 19-bp oligonucleotides solution can be discriminated using the prototype device fabricated in 1- μm double-poly double-metal standard CMOS process. The detection limit was measured as 1.1 ng/μl with a dynamic range of 40 dB and the transient response time was measured less than 20 seconds.

  3. Performance evaluation of the Champagne source reconstruction algorithm on simulated and real M/EEG data.

    PubMed

    Owen, Julia P; Wipf, David P; Attias, Hagai T; Sekihara, Kensuke; Nagarajan, Srikantan S

    2012-03-01

    In this paper, we present an extensive performance evaluation of a novel source localization algorithm, Champagne. It is derived in an empirical Bayesian framework that yields sparse solutions to the inverse problem. It is robust to correlated sources and learns the statistics of non-stimulus-evoked activity to suppress the effect of noise and interfering brain activity. We tested Champagne on both simulated and real M/EEG data. The source locations used for the simulated data were chosen to test the performance on challenging source configurations. In simulations, we found that Champagne outperforms the benchmark algorithms in terms of both the accuracy of the source localizations and the correct estimation of source time courses. We also demonstrate that Champagne is more robust to correlated brain activity present in real MEG data and is able to resolve many distinct and functionally relevant brain areas with real MEG and EEG data. Copyright © 2011 Elsevier Inc. All rights reserved.

  4. Application of digital image correlation for long-distance bridge deflection measurement

    NASA Astrophysics Data System (ADS)

    Tian, Long; Pan, Bing; Cai, Youfa; Liang, Hui; Zhao, Yan

    2013-06-01

    Due to its advantages of non-contact, full-field and high-resolution measurement, digital image correlation (DIC) method has gained wide acceptance and found numerous applications in the field of experimental mechanics. In this paper, the application of DIC for real-time long-distance bridge deflection detection in outdoor environments is studied. Bridge deflection measurement using DIC in outdoor environments is more challenging than regular DIC measurements performed under laboratory conditions. First, much more image noise due to variations in ambient light will be presented in the images recorded in outdoor environments. Second, how to select the target area becomes a key factor because long-distance imaging results in a large field of view of the test object. Finally, the image acquisition speed of the camera must be high enough (larger than 100 fps) to capture the real-time dynamic motion of a bridge. In this work, the above challenging issues are addressed and several improvements were made to DIC method. The applicability was demonstrated by real experiments. Experimental results indicate that the DIC method has great potentials in motion measurement in various large building structures.

  5. Real-time control data wrangling for development of mathematical control models of technological processes

    NASA Astrophysics Data System (ADS)

    Vasilyeva, N. V.; Koteleva, N. I.; Fedorova, E. R.

    2018-05-01

    The relevance of the research is due to the need to stabilize the composition of the melting products of copper-nickel sulfide raw materials in the Vanyukov furnace. The goal of this research is to identify the most suitable methods for the aggregation of the real time data for the development of a mathematical model for control of the technological process of melting copper-nickel sulfide raw materials in the Vanyukov furnace. Statistical methods of analyzing the historical data of the real technological object and the correlation analysis of process parameters are described. Factors that exert the greatest influence on the main output parameter (copper content in matte) and ensure the physical-chemical transformations are revealed. An approach to the processing of the real time data for the development of a mathematical model for control of the melting process is proposed. The stages of processing the real time information are considered. The adopted methodology for the aggregation of data suitable for the development of a control model for the technological process of melting copper-nickel sulfide raw materials in the Vanyukov furnace allows us to interpret the obtained results for their further practical application.

  6. Developments in real-time monitoring for geologic hazard warnings (Invited)

    NASA Astrophysics Data System (ADS)

    Leith, W. S.; Mandeville, C. W.; Earle, P. S.

    2013-12-01

    Real-time data from global, national and local sensor networks enable prompt alerts and warnings of earthquakes, tsunami, volcanic eruptions, geomagnetic storms , broad-scale crustal deformation and landslides. State-of-the-art seismic systems can locate and evaluate earthquake sources in seconds, enabling 'earthquake early warnings' to be broadcast ahead of the damaging surface waves so that protective actions can be taken. Strong motion monitoring systems in buildings now support near-real-time structural damage detection systems, and in quiet times can be used for state-of-health monitoring. High-rate GPS data are being integrated with seismic strong motion data, allowing accurate determination of earthquake displacements in near-real time. GPS data, combined with rainfall, groundwater and geophone data, are now used for near-real-time landslide monitoring and warnings. Real-time sea-floor water pressure data are key for assessing tsunami generation by large earthquakes. For monitoring remote volcanoes that lack local ground-based instrumentation, the USGS uses new technologies such as infrasound arrays and the worldwide lightning detection array to detect eruptions in progress. A new real-time UV-camera system for measuring the two dimensional SO2 flux from volcanic plumes will allow correlations with other volcano monitoring data streams to yield fundamental data on changes in gas flux as an eruption precursor, and how magmas de-gas prior to and during eruptions. Precision magnetic field data support the generation of real-time indices of geomagnetic disturbances (Dst, K and others), and can be used to model electrical currents in the crust and bulk power system. Ground-induced electrical current monitors are used to track those currents so that power grids can be effectively managed during geomagnetic storms. Beyond geophysical sensor data, USGS is using social media to rapidly detect possible earthquakes and to collect firsthand accounts of the impacts of natural disasters useful for social science studies. Monitoring of tweets in real-time, when analyzed statistically and geographically, can give a prompt indication of an earthquake, well before seismic networks in sparsely instrumented regions can locate an event and determine its magnitude. With more and more real-time data becoming available, new applications and products are inevitable.

  7. Real time emotion aware applications: a case study employing emotion evocative pictures and neuro-physiological sensing enhanced by Graphic Processor Units.

    PubMed

    Konstantinidis, Evdokimos I; Frantzidis, Christos A; Pappas, Costas; Bamidis, Panagiotis D

    2012-07-01

    In this paper the feasibility of adopting Graphic Processor Units towards real-time emotion aware computing is investigated for boosting the time consuming computations employed in such applications. The proposed methodology was employed in analysis of encephalographic and electrodermal data gathered when participants passively viewed emotional evocative stimuli. The GPU effectiveness when processing electroencephalographic and electrodermal recordings is demonstrated by comparing the execution time of chaos/complexity analysis through nonlinear dynamics (multi-channel correlation dimension/D2) and signal processing algorithms (computation of skin conductance level/SCL) into various popular programming environments. Apart from the beneficial role of parallel programming, the adoption of special design techniques regarding memory management may further enhance the time minimization which approximates a factor of 30 in comparison with ANSI C language (single-core sequential execution). Therefore, the use of GPU parallel capabilities offers a reliable and robust solution for real-time sensing the user's affective state. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  8. Digital sleep logs reveal potential impacts of modern temporal structure on class performance in different chronotypes.

    PubMed

    Smarr, Benjamin Lee

    2015-02-01

    Stability of sleep and circadian rhythms are important for healthy learning and memory. While experimental manipulations of lifestyle and learning outcomes present major obstacles, the ongoing increase in data sources allows retrospective data mining of people's sleep timing variation. Here I use digital sleep-log data generated by 1109 students in a biology lab course at the University of Washington to test the hypothesis that higher variance in time asleep and later sleep-onset times negatively correlate with class performance, used here as a real-world proxy for learning and memory. I find that sleep duration variance and mean sleep-onset times both significantly correlate with class performance. These correlations are powerful on weeknights but undetectable on Friday and Saturday nights ("free nights"). Finally, although these data come with no demographic information beyond sex, the constructed demographic groups of "larks" and "owls" within the sexes reveal a significant decrease in performance of owls relative to larks in male students, whereas the correlation of performance with sleep-onset time for all male students was only a near-significant trend. This provides a proof of concept that deeper demographic mining of digital logs in the future may identify subgroups for which certain sleep phenotypes have greater predictive value for performance outcomes. The data analyzed are consistent with known patterns, including sleep-timing delays from weeknights to free nights and sleep-timing delays in men relative to women. These findings support the hypothesis that modern schedule impositions on sleep and circadian timing have consequences for real-world learning and memory. This study also highlights the low-cost, large-scale benefits of personal, daily, digital records as an augmentation of sleep and circadian studies. © 2015 The Author(s).

  9. Near real-time monitoring of UT1 with geodetic VLBI

    NASA Astrophysics Data System (ADS)

    Haas, R.; Hobiger, T.; Sekido, M.; Koyama, Y.; Kondo, T.; Takiguchi, H.; Kurihara, S.; Kokado, K.; Tanimoto, D.; Nozawa, K.; Wagner, J.; Ritakari, J.; Mujunen, A.; Uunila, M.

    2011-07-01

    Geodetic VLBI is unique among the geodetic space techniques since it provides a direct connection between the international terrestrial reference frame and the international celestial reference frame. The Earth rotation angle, usually expressed as UT1, can be determined directly from geodetic VLBI observations. Accurate information about the Earth rotation angle is necessary and important for navigation purposes, in particular for satellite missions and space navigation. A near real-time knowledge of UT1 with high accuracy is therefore highly desirable. During the last few years the advances in data transfer over high-speed optical fibre lines have made it possible to electronically send the observational data from a VLBI radio telescope on one side of the globe in real-time to a VLBI correlator on the other side of the globe. Thus, data of two telescopes on opposite sides of the Earth, forming a long east-west oriented baseline, can be correlated in near real-time. Furthermore, advances in automated processing of the correlation results have made it possible to derive the Earth rotation angle UT1 in near real-time. Since 2007, the VLBI research groups in Sweden, Finland and Japan collaborate to derive UT1 in near real-time. Several dedicated so-called ultra-rapid UT1-sessions with 1-2 hours duration were performed. It was shown that final UT1-results can be derived within a few minutes after the end of an observing session (Sekido et al., 2008; Matsuzaka et al., 2008). The quality of the UT1-results is on the same level as the so-called IERS rapid solutions, but with a much lower latency (Haas et al., 2010). Recently, the ultra-rapid approach has been applied to standard 24 hour long VLBI observing sessions that are organized by the International VLBI Service for Geodesy and Astrometry (IVS). The long east-west baseline between Onsala (Sweden) and Tsukuba (Japan) is used to derive UT1 with a sliding window approach already during the ongoing IVS-session. The data processing and analysis is performed with a fully automated analysis software (Hobiger et al., 2010). We present results from the ultra-rapid UT1-sessions, both, from dedicated one-baseline sessions, as well from 24-hour ultra-rapid sessions during standard IVS-experiments. The near real-time UT1 results are compared to corresponding post-processing results, and results from independent analyses and techniques. Refrences: Sekido et al. (2008) Ultra-rapid UT1 measurements by e-VLBI, Earth Planets and Space, Vol. 60, 865-870. Matsuzaka et al. (2008) Ultra Rapid UT1 Experiment with e-VLBI, In: Proc. 5th IVS General Meeting, 68-71. Haas R et al. (2010) Ultra-Rapid DUT1-Observations with E-VLBI. Artificial Satellites, 45, 75-79. Hobiger et al. (2010) Fully automated VLBI analysis with c5++ for ultra-rapid determination of UT1, Earth Planets Space.

  10. Fast gradient-based algorithm on extended landscapes for wave-front reconstruction of Earth observation satellite

    NASA Astrophysics Data System (ADS)

    Thiebaut, C.; Perraud, L.; Delvit, J. M.; Latry, C.

    2016-07-01

    We present an on-board satellite implementation of a gradient-based (optical flows) algorithm for the shifts estimation between images of a Shack-Hartmann wave-front sensor on extended landscapes. The proposed algorithm has low complexity in comparison with classical correlation methods which is a big advantage for being used on-board a satellite at high instrument data rate and in real-time. The electronic board used for this implementation is designed for space applications and is composed of radiation-hardened software and hardware. Processing times of both shift estimations and pre-processing steps are compatible of on-board real-time computation.

  11. Small-world bias of correlation networks: From brain to climate

    NASA Astrophysics Data System (ADS)

    Hlinka, Jaroslav; Hartman, David; Jajcay, Nikola; Tomeček, David; Tintěra, Jaroslav; Paluš, Milan

    2017-03-01

    Complex systems are commonly characterized by the properties of their graph representation. Dynamical complex systems are then typically represented by a graph of temporal dependencies between time series of state variables of their subunits. It has been shown recently that graphs constructed in this way tend to have relatively clustered structure, potentially leading to spurious detection of small-world properties even in the case of systems with no or randomly distributed true interactions. However, the strength of this bias depends heavily on a range of parameters and its relevance for real-world data has not yet been established. In this work, we assess the relevance of the bias using two examples of multivariate time series recorded in natural complex systems. The first is the time series of local brain activity as measured by functional magnetic resonance imaging in resting healthy human subjects, and the second is the time series of average monthly surface air temperature coming from a large reanalysis of climatological data over the period 1948-2012. In both cases, the clustering in the thresholded correlation graph is substantially higher compared with a realization of a density-matched random graph, while the shortest paths are relatively short, showing thus distinguishing features of small-world structure. However, comparable or even stronger small-world properties were reproduced in correlation graphs of model processes with randomly scrambled interconnections. This suggests that the small-world properties of the correlation matrices of these real-world systems indeed do not reflect genuinely the properties of the underlying interaction structure, but rather result from the inherent properties of correlation matrix.

  12. Small-world bias of correlation networks: From brain to climate.

    PubMed

    Hlinka, Jaroslav; Hartman, David; Jajcay, Nikola; Tomeček, David; Tintěra, Jaroslav; Paluš, Milan

    2017-03-01

    Complex systems are commonly characterized by the properties of their graph representation. Dynamical complex systems are then typically represented by a graph of temporal dependencies between time series of state variables of their subunits. It has been shown recently that graphs constructed in this way tend to have relatively clustered structure, potentially leading to spurious detection of small-world properties even in the case of systems with no or randomly distributed true interactions. However, the strength of this bias depends heavily on a range of parameters and its relevance for real-world data has not yet been established. In this work, we assess the relevance of the bias using two examples of multivariate time series recorded in natural complex systems. The first is the time series of local brain activity as measured by functional magnetic resonance imaging in resting healthy human subjects, and the second is the time series of average monthly surface air temperature coming from a large reanalysis of climatological data over the period 1948-2012. In both cases, the clustering in the thresholded correlation graph is substantially higher compared with a realization of a density-matched random graph, while the shortest paths are relatively short, showing thus distinguishing features of small-world structure. However, comparable or even stronger small-world properties were reproduced in correlation graphs of model processes with randomly scrambled interconnections. This suggests that the small-world properties of the correlation matrices of these real-world systems indeed do not reflect genuinely the properties of the underlying interaction structure, but rather result from the inherent properties of correlation matrix.

  13. Comparison of Three Real-Time Measurement Methods for Airborne Ultrafine Particles in the Silicon Alloy Industry.

    PubMed

    Kero, Ida Teresia; Jørgensen, Rikke Bramming

    2016-09-01

    The aim of this study was to compare the applicability and the correlation between three commercially available instruments capable of detection, quantification, and characterization of ultrafine airborne particulate matter in the industrial setting of a tapping area in a silicon alloy production plant. The number concentration of ultrafine particles was evaluated using an Electric Low Pressure Impactor (ELPI(TM)), a Fast Mobility Particle Sizer (FMPS(TM)), and a Condensation Particle Counter (CPC). The results are discussed in terms of particle size distribution and temporal variations linked to process operations. The instruments show excellent temporal covariation and the correlation between the FMPS and ELPI is good. The advantage of the FMPS is the excellent time- and size resolution of the results. The main advantage of the ELPI is the possibility to collect size-fractionated samples of the dust for subsequent analysis by, for example, electron microscopy. The CPC does not provide information about the particle size distribution and its correlation to the other two instruments is somewhat poor. Nonetheless, the CPC gives basic, real-time information about the ultrafine particle concentration and can therefore be used for source identification.

  14. NASA SMART Probe: Breast Cancer Application

    NASA Technical Reports Server (NTRS)

    Mah, Robert W.; Norvig, Peter (Technical Monitor)

    2000-01-01

    There is evidence in breast cancer and other malignancies that the physiologic environment within a tumor correlates with clinical outcome. We are developing a unique percutaneous Smart Probe to be used at the time of needle biopsy of the breast. The Smart Probe will simultaneously measure multiple physiologic parameters within a breast tumor. Direct and indirect measurements of tissue oxygen levels, blood flow, pH, and tissue fluid pressure will be analyzed in real-time. These parameters will be interpreted individually and collectively by innovative neural network techniques using advanced intelligent software. The goals are 1) develop a pecutaneous Smart Probe with multiple sensor modalities and applying advanced Information Technologies to provide real time diagnostic information of the tissue at tip of the probe, 2) test the percutaneous Smart Probe in women with benign and malignant breast masses who will be undergoing surgical biopsy, 3) correlate probe sensor data with benign and malignant status of breast masses, 4) determine whether the probe can detect physiologic differences within a breast tumor, and its margins, and in adjacent normal breast tissue, 5) correlate probe sensor data with known prognostic factors for breast caner, including tumor size, tumor grade, axillary lymph node metastases, estrogen receptor and progesterone receptor status.

  15. Comparison of Three Real-Time Measurement Methods for Airborne Ultrafine Particles in the Silicon Alloy Industry

    PubMed Central

    Kero, Ida Teresia; Jørgensen, Rikke Bramming

    2016-01-01

    The aim of this study was to compare the applicability and the correlation between three commercially available instruments capable of detection, quantification, and characterization of ultrafine airborne particulate matter in the industrial setting of a tapping area in a silicon alloy production plant. The number concentration of ultrafine particles was evaluated using an Electric Low Pressure Impactor (ELPITM), a Fast Mobility Particle Sizer (FMPSTM), and a Condensation Particle Counter (CPC). The results are discussed in terms of particle size distribution and temporal variations linked to process operations. The instruments show excellent temporal covariation and the correlation between the FMPS and ELPI is good. The advantage of the FMPS is the excellent time- and size resolution of the results. The main advantage of the ELPI is the possibility to collect size-fractionated samples of the dust for subsequent analysis by, for example, electron microscopy. The CPC does not provide information about the particle size distribution and its correlation to the other two instruments is somewhat poor. Nonetheless, the CPC gives basic, real-time information about the ultrafine particle concentration and can therefore be used for source identification. PMID:27598180

  16. The near real time image navigation of pictures returned by Voyager 2 at Neptune

    NASA Technical Reports Server (NTRS)

    Underwood, Ian M.; Bachman, Nathaniel J.; Taber, William L.; Wang, Tseng-Chan; Acton, Charles H.

    1990-01-01

    The development of a process for performing image navigation in near real time is described. The process was used to accurately determine the camera pointing for pictures returned by the Voyager 2 spacecraft at Neptune Encounter. Image navigation improves knowledge of the pointing of an imaging instrument at a particular epoch by correlating the spacecraft-relative locations of target bodies in inertial space with the locations of their images in a picture taken at that epoch. More than 8,500 pictures returned by Voyager 2 at Neptune were processed in near real time. The results were used in several applications, including improving pointing knowledge for nonimaging instruments ('C-smithing'), making 'Neptune, the Movie', and providing immediate access to geometrical quantities similar to those traditionally supplied in the Supplementary Experiment Data Record.

  17. Correlation of immune activation with HIV-1 RNA levels assayed by real-time RT-PCR in HIV-1 Subtype C infected patients in Northern India

    PubMed Central

    Agarwal, Atima; Sankaran, Sumathi; Vajpayee, Madhu; Sreenivas, V; Seth, Pradeep; Dandekar, Satya

    2014-01-01

    Background Assays with specificity and cost effectiveness are needed for the measurement of HIV-1 burden to monitor disease progression or response to anti-retroviral therapy (ART) in HIV-1 subtype C infected patients. Objectives The objective of this study was to develop and validate an affordable; one step Real-Time RT-PCR assay with high specificity and sensitivity to measure plasma HIV-1 loads in HIV-1 subtype C infected patients. Results We developed an RT-PCR assay to detect and quantitate plasma HIV-1 levels in HIV-1 subtype C infected patients. An inverse correlation between plasma viral loads (PVL) and CD4+ T-cell numbers was detected at all CDC stages. Significant correlations were found between CD8+ T-cell activation and PVL, as well as with the clinical and immunological status of the patients. Conclusions The RT-PCR assay provides a sensitive method to measure PVL in HIV-1 subtype C infected patients. Viral loads correlated with immune activation and can be used to monitor HIV care in India. PMID:17962068

  18. The Quasar Network Observations in e-VLBI Mode

    NASA Astrophysics Data System (ADS)

    Bezrukov, I.; Finkelstein, A.; Ipatov, A.; Kaidanovsky, A.; Mikhailov, A.; Salnikov, A.; Yakovlev, V.

    2011-07-01

    This paper describes activity of the Institute of Applied Astronomy in developing real-time VLBI-system using high speed digital communication links. Real-time VLBI-technology has been developing at IAA since 2007 when the very first experiment was successfully done with Haystack observatory. All observatories of VLBI-Network Quasar were connected by "last mile" communication channels and via the Internet at 100 Mbps rate. Additional UNIX servers were installed for data buffering. Now e-VLBI sessions are carried out routinely within domestic VLBI-programs for UT1-determination. Observational data of 1-hour sessions are transmitted simultaneously from Svetloe, Zelenchukskaya and Badary observatories to the IAA Data Processing Center in Saint-Petersburg through fiber lines at 50-70 Mbps via Tsunami-UDP protocol. In September 2010 few scans were successfully transmitted from Quasar-Network observatories to Correlator Center at Shanghai observatory and vice-versa from Shanghai observatory to Correlator of RAS. Within these experiments observation data recorded by Mark 5B recorder are transmitted to the buffer server during time interval when an antenna pointed from one source to another. This procedure allows us to reduce total time of obtaining final result by 30%. Now an advanced algorithm for automation of the data transmitting process from the recorder to correlator is developing.

  19. Quantification of Campylobacter spp. in pig feces by direct real-time PCR with an internal control of extraction and amplification.

    PubMed

    Leblanc-Maridor, Mily; Garénaux, Amélie; Beaudeau, François; Chidaine, Bérangère; Seegers, Henri; Denis, Martine; Belloc, Catherine

    2011-04-01

    The rapid and direct quantification of Campylobacter spp. in complex substrates like feces or environmental samples is crucial to facilitate epidemiological studies on Campylobacter in pig production systems. We developed a real-time PCR assay for detecting and quantifying Campylobacter spp. directly in pig feces with the use of an internal control. Campylobacter spp. and Yersinia ruckeri primers-probes sets were designed and checked for specificity with diverse Campylobacter, related organisms, and other bacterial pathogens before being used in field samples. The quantification of Campylobacter spp. by the real-time PCR then was realized on 531 fecal samples obtained from experimentally and naturally infected pigs; the numeration of Campylobacter on Karmali plate was done in parallel. Yersinia ruckeri, used as bacterial internal control, was added to the samples before DNA extraction to control DNA-extraction and PCR-amplification. The sensitivity of the PCR assay was 10 genome copies. The established Campylobacter real-time PCR assay showed a 7-log-wide linear dynamic range of quantification (R²=0.99) with a detection limit of 200 Colony Forming Units of Campylobacter per gram of feces. A high correlation was found between the results obtained by real-time PCR and those by culture at both qualitative and quantitative levels. Moreover, DNA extraction followed by real-time PCR reduced the time needed for analysis to a few hours (within a working day). In conclusion, the real-time PCR developed in this study provides new tools for further epidemiological surveys to investigate the carriage and excretion of Campylobacter by pigs. Copyright © 2011 Elsevier B.V. All rights reserved.

  20. Five-dimensional ultrasound system for soft tissue visualization.

    PubMed

    Deshmukh, Nishikant P; Caban, Jesus J; Taylor, Russell H; Hager, Gregory D; Boctor, Emad M

    2015-12-01

    A five-dimensional ultrasound (US) system is proposed as a real-time pipeline involving fusion of 3D B-mode data with the 3D ultrasound elastography (USE) data as well as visualization of these fused data and a real-time update capability over time for each consecutive scan. 3D B-mode data assist in visualizing the anatomy of the target organ, and 3D elastography data adds strain information. We investigate the feasibility of such a system and show that an end-to-end real-time system, from acquisition to visualization, can be developed. We present a system that consists of (a) a real-time 3D elastography algorithm based on a normalized cross-correlation (NCC) computation on a GPU; (b) real-time 3D B-mode acquisition and network transfer; (c) scan conversion of 3D elastography and B-mode volumes (if acquired by 4D wobbler probe); and (d) visualization software that fuses, visualizes, and updates 3D B-mode and 3D elastography data in real time. We achieved a speed improvement of 4.45-fold for the threaded version of the NCC-based 3D USE versus the non-threaded version. The maximum speed was 79 volumes/s for 3D scan conversion. In a phantom, we validated the dimensions of a 2.2-cm-diameter sphere scan-converted to B-mode volume. Also, we validated the 5D US system visualization transfer function and detected 1- and 2-cm spherical objects (phantom lesion). Finally, we applied the system to a phantom consisting of three lesions to delineate the lesions from the surrounding background regions of the phantom. A 5D US system is achievable with real-time performance. We can distinguish between hard and soft areas in a phantom using the transfer functions.

  1. A novel real-time duplex PCR assay for detecting penA and ponA genotypes in Neisseria gonorrhoeae: Comparison with phenotypes determined by the E-test.

    PubMed

    Vernel-Pauillac, Frédérique; Merien, Fabrice

    2006-12-01

    For many years, the pathogenic bacterium Neisseria gonorrhoeae, the etiologic agent of gonorrhea, was generally susceptible to penicillin, until the emergence of resistant strains. Well-characterized genetic variations in the penicillin resistance-determining region correlate with decreased susceptibility to penicillin. At least 5 genes (penA, penB, mtrR, ponA, and penC) are involved in the chromosomally mediated resistance to this antibiotic. To date, no development of multiplex PCR assays targeting a range of gonococcal genes and variations as a means of predicting antibiotic resistance has been reported. The aim of this study was to develop a duplex assay using DNA from isolated strains. We describe the development and evaluation on the LightCycler platform of a real-time duplex PCR assay (hybridization probe format) for rapid and specific detection of ponA and penA variations, predicting penicillin susceptibilities. The real-time duplex PCR assay successfully detected variations in ponA and penA genes by use of distinct melting temperatures from a total of 120 Neisseria gonorrhoeae isolates. Moreover, the variation profiles obtained with the real-time PCR and the melting analysis showed good correlation with the pattern of penicillin susceptibility generated with classical antibiograms. Nucleotide sequencing data were in complete agreement with multiplex assay results. The presented assay is suitable for the detection of chromosomally mediated resistant strains of Neisseria gonorrhoeae in genotyping studies and could be valuable in the effective antimicrobial strategy to gonococci.

  2. Pneumococcal colonisation density: a new marker for disease severity in HIV-infected adults with pneumonia

    PubMed Central

    Albrich, Werner C; Madhi, Shabir A; Adrian, Peter V; van Niekerk, Nadia; Telles, Jean-Noel; Ebrahim, N; Messaoudi, Melina; Paranhos-Baccalà, Glaucia; Giersdorf, Sven; Vernet, Guy; Mueller, Beat; Klugman, Keith P

    2014-01-01

    Objective A high genomic load of Pneumococcus from blood or cerebrospinal fluid has been associated with increased mortality. We aimed to analyse whether nasopharyngeal colonisation density in HIV-infected patients with community-acquired pneumonia (CAP) is associated with markers of disease severity or poor outcome. Methods Quantitative lytA real-time PCR was performed on nasopharyngeal swabs in HIV-infected South African adults hospitalised for acute CAP at Chris Hani Baragwanath Hospital, Soweto, South Africa. Pneumonia aetiology was considered pneumococcal if any sputum culture or Gram stain, urinary pneumococcal C-polysaccharide-based antigen, blood culture or whole blood lytA real-time PCR revealed pneumococci. Results There was a moderate correlation between the mean nasopharyngeal colonisation densities and increasing CURB65 scores among all-cause patients with pneumonia (Spearman correlation coefficient r=0.15, p=0.06) or with the Pitt bacteraemia score among patients with pneumococcal bacteraemia (p=0.63). In patients with pneumococcal pneumonia, nasopharyngeal pneumococcal colonisation density was higher among non-survivors than survivors (7.7 vs 6.1 log10 copies/mL, respectively, p=0.02) and among those who had pneumococci identified from blood cultures and/or by whole blood lytA real-time PCR than those with non-bacteraemic pneumococcal pneumonia (6.6 vs 5.6 log10 copies/mL, p=0.03). Nasopharyngeal colonisation density correlated positively with the biomarkers procalcitonin (Spearman correlation coefficient r=0.37, p<0.0001), proadrenomedullin (r=0.39, p=0.008) and copeptin (r=0.30, p=0.01). Conclusions In addition to its previously reported role as a diagnostic tool for pneumococcal pneumonia, quantitative nasopharyngeal colonisation density also correlates with mortality and prognostic biomarkers. It may also be useful as a severity marker for pneumococcal pneumonia in HIV-infected adults. PMID:25113557

  3. Comparison of Hybrid Capture 2 Assay with Real-time-PCR for Detection and Quantitation of Hepatitis B Virus DNA

    PubMed Central

    Jahan, Munira; Lutful Moben, Ahmed; Tabassum, Shahina

    2014-01-01

    ABSTRACT Background Both real-time-polymerase chain reaction (PCR) and hybrid capture 2 (HC2) assay can detect and quantify hepatitis B virus (HBV) DNA. However, real-time-PCR can detect a wide range of HBV DNA, while HC2 assay could not detect lower levels of viremia. The present study was designed to detect and quantify HBV DNA by real-time-PCR and HC2 assay and compare the quantitative data of these two assays. Materials and methods A cross-sectional study was conducted in between July 2010 and June 2011. A total of 66 serologically diagnosed chronic hepatitis B (CHB) patients were selected for the study. Real-time-PCR and HC2 assay was done to detect HBV DNA. Data were analyzed by statistical Package for the social sciences (SPSS). Results Among 66 serologically diagnosed chronic hepatitis B patients 40 (60.61%) patients had detectable and 26 (39.39%) had undetectable HBV DNA by HC2 assay. Concordant results were obtained for 40 (60.61%) out of these 66 patients by real-time-PCR and HC2 assay with mean viral load of 7.06 ± 1.13 log10 copies/ml and 6.95 ± 1.08 log10 copies/ml, respectively. In the remaining 26 patients, HBV DNA was detectable by real-time-PCR in 20 patients (mean HBV DNA level was 3.67 ± 0.72 log10 copies/ml. However, HBV DNA could not be detectable in six cases by the both assays. The study showed strong correlation (r = 0.915) between real-time-PCR and HC2 assay for the detection and quantification of HBV DNA. Conclusion HC2 assay may be used as an alternative to real-time-PCR for CHB patients. How to cite this article: Majid F, Jahan M, Moben AL, Tabassum S. Comparison of Hybrid Capture 2 Assay with Real-time-PCR for Detection and Quantitation of Hepatitis B Virus DNA. Euroasian J Hepato-Gastroenterol 2014;4(1):31-35. PMID:29264316

  4. Cognitive functioning is more closely related to real-life mobility than to laboratory-based mobility parameters.

    PubMed

    Giannouli, Eleftheria; Bock, Otmar; Zijlstra, Wiebren

    2018-03-01

    Increasing evidence indicates that mobility depends on cognitive resources, but the exact relationships between various cognitive functions and different mobility parameters still need to be investigated. This study examines the hypothesis that cognitive functioning is more closely related to real-life mobility performance than to mobility capacity as measured with standardized laboratory tests. The final sample used for analysis consisted of 66 older adults (72.3 ± 5.6 years). Cognition was assessed by measures of planning (HOTAP test), spatial working memory (Grid-Span test) and visuospatial attention (Attention Window test). Mobility capacity was assessed by an instrumented version of the Timed Up-and-Go test (iTUG). Mobility performance was assessed with smartphones which collected accelerometer and GPS data over one week to determine the spatial extent and temporal duration of real-life activities. Data analyses involved an exploratory factor analysis and correlation analyses. Mobility measures were reduced to four orthogonal factors: the factor 'real-life mobility' correlated significantly with most cognitive measures (between r   =  .229 and r   =  .396); factors representing 'sit-to-stand transition' and 'turn' correlated with fewer cognitive measures (between r   =  .271 and r   =  .315 and between r   =  .210 and r   =  .316, respectively), and the factor representing straight gait correlated with only one cognitive measure ( r   =  .237). Among the cognitive functions tested, visuospatial attention was associated with most mobility measures, executive functions with fewer and spatial working memory with only one mobility measure. Capacity and real-life performance represent different aspects of mobility. Real-life mobility is more closely associated with cognition than mobility capacity, and in our data this association is most pronounced for visuospatial attention. The close link between real-life mobility and visuospatial attention should be considered by interventions targeting mobility in old age.

  5. Ultra-rapid EOP determination with VLBI

    NASA Astrophysics Data System (ADS)

    Haas, Rüdiger; Kurihara, Shinobu; Nozawa, Kentaro; Hobiger, Thomas; Lovell, Jim; McCallum, Jamie; Quick, Jonathan

    2013-04-01

    In 2007 the Geospatial information Authority of Japan (GSI) and the Onsala Space Observatory (OSO) started a project aiming at determining the earth rotation angle, usually expressed as dUT1, in near real-time. In the beginning of this project dedicated one hour long one-baseline experiments were observed periodically using the VLBI stations Onsala (Sweden) and Tsukuba (Japan). The strategy is that the observed VLBI-data are sent in real-time via the international optical fibre backbone to the VLBI-correlator at Tsukuba where the data are correlated and analyzed in near-real time, producing ultra-rapid dUT1 results. An offline version of this strategy has been adopted in 2009 for the regular VLBI intensive series INT-2 involving Wettzell (Germany) and Tsukuba. Since March 2010 the INT-2 is using real-time e-transfer, too, and since June 2010 also automated analysis. Starting in 2009 the ultra-rapid approach was applied to regular 24 hour long VLBI-sessions that involve Tsukuba and Onsala, so that ultra-rapid dUT1 results can be produced already during ongoing VLBI-sessions. This strategy was successfully operated during the 15 days long CONT11 campaign. In 2011 the ultra-rapid strategy was extended to involve a network of VLBI-stations, so that not only dUT1 but also the polar motion components can be determined in near real-time. Initially, in November 2011 a dedicated three-station session was observed involving Onsala, Tsukuba and Hobart (Tasmania, Australia). In 2012 several regular 24 hour long IVS-sessions that involved Onsala, Tsukuba and HartRAO (South Africa) were operated with the ultra-rapid strategy, and in several cases also Hobart was added as a fourth station. For this project we use the new analysis software c5++ developed by the National Institute of Information and Communications Technology (NICT). In this presentation we give an overview of the UREOP-project, describe the recent developments, and discuss the obtained results.

  6. Impact of left ventricular outflow tract area on systolic outflow velocity in hypertrophic cardiomyopathy: a real-time three-dimensional echocardiographic study

    NASA Technical Reports Server (NTRS)

    Qin, Jian Xin; Shiota, Takahiro; Lever, Harry M.; Rubin, David N.; Bauer, Fabrice; Kim, Yong Jin; Sitges, Marta; Greenberg, Neil L.; Drinko, Jeanne K.; Martin, Maureen; hide

    2002-01-01

    OBJECTIVES: The aim of this study was to use real-time three-dimensional echocardiography (3DE) to investigate the quantitative relation between minimal left ventricular (LV) outflow tract area (A(LVOT)) and maximal LV outflow tract (LVOT) velocity in patients with hypertrophic obstructive cardiomyopathy (HCM). BACKGROUND: In patients with HCM, LVOT velocity should change inversely with minimal A(LVOT) unless LVOT obstruction reduces the pumping capacity of the ventricle. METHODS: A total of 25 patients with HCM with systolic anterior motion (SAM) of the mitral valve leaflets underwent real-time 3DE. The smallest A(LVOT) during systole was measured using anatomically oriented two-dimensional "C-planes" within the pyramidal 3DE volume. Maximal velocity across LVOT was evaluated by two-dimensional Doppler echocardiography (2DE). For comparison with 3DE A(LVOT), the SAM-septal distance was determined by 2DE. RESULTS: Real-time 3DE provided unique information about the dynamic SAM-septal relation during systole, with A(LVOT) ranging from 0.6 to 5.2 cm(2) (mean: 2.2 +/- 1.4 cm(2)). Maximal velocity (v) correlated inversely with A(LVOT) (v = 496 A(LVOT)(-0.80), r = -0.95, p < 0.001), but the exponent (-0.80) was significantly different from -1.0 (95% confidence interval: -0.67 to -0.92), indicating a significant impact of small A(LVOT) on the peak LVOT flow rate. By comparison, the best correlation between velocity and 2DE SAM-septal distance was significantly (p < 0.01) poorer at -0.83, indicating the superiority of 3DE for assessing A(LVOT). CONCLUSIONS: Three-dimensional echocardiography-measured A(LVOT) provides an assessment of HCM geometry that is superior to 2DE methods. These data indicate that the peak LVOT flow rate appears to be significantly decreased by reduced A(LVOT). Real-time 3DE is a potentially valuable clinical tool for assessing patients with HCM.

  7. Investigation of hit-and-run crash occurrence and severity using real-time loop detector data and hierarchical Bayesian binary logit model with random effects.

    PubMed

    Xie, Meiquan; Cheng, Wen; Gill, Gurdiljot Singh; Zhou, Jiao; Jia, Xudong; Choi, Simon

    2018-02-17

    Most of the extensive research dedicated to identifying the influential factors of hit-and-run (HR) crashes has utilized typical maximum likelihood estimation binary logit models, and none have employed real-time traffic data. To fill this gap, this study focused on investigating factors contributing to HR crashes, as well as the severity levels of HR. This study analyzed 4-year crash and real-time loop detector data by employing hierarchical Bayesian models with random effects within a sequential logit structure. In addition to evaluation of the impact of random effects on model fitness and complexity, the prediction capability of the models was examined. Stepwise incremental sensitivity and specificity were calculated and receiver operating characteristic (ROC) curves were utilized to graphically illustrate the predictive performance of the model. Among the real-time flow variables, the average occupancy and speed from the upstream detector were observed to be positively correlated with HR crash possibility. The average upstream speed and speed difference between upstream and downstream speeds were correlated with the occurrence of severe HR crashes. In addition to real-time factors, other variables found influential for HR and severe HR crashes were length of segment, adverse weather conditions, dark lighting conditions with malfunctioning street lights, driving under the influence of alcohol, width of inner shoulder, and nighttime. This study suggests the potential traffic conditions of HR and severe HR occurrence, which refer to relatively congested upstream traffic conditions with high upstream speed and significant speed deviations on long segments. The above findings suggest that traffic enforcement should be directed toward mitigating risky driving under the aforementioned traffic conditions. Moreover, enforcement agencies may employ alcohol checkpoints to counter driving under the influence (DUI) at night. With regard to engineering improvements, wider inner shoulders may be constructed to potentially reduce HR cases and street lights should be installed and maintained in working condition to make roads less prone to such crashes.

  8. Quantitative analysis of dengue-2 virus RNA during the extrinsic incubation period in individual Aedes aegypti.

    PubMed

    Richardson, Jason; Molina-Cruz, Alvaro; Salazar, Ma Isabel; Black, William

    2006-01-01

    Dengue virus-2 (DENV-2) RNA was quantified from the midgut and legs of individual Aedes aegypti at each of 14 days postinfectious blood meal (dpi) in a DENV-2 susceptible strain from Chetumal, Mexico. A SYBR Green I based strand-specific, quantitative real-time reverse transcription-polymerase chain reaction (RT-PCR) assay was developed. The lower detection and quantitation limits were 20 and 200 copies per reaction, respectively. Amounts of positive and negative strand viral RNA strands were correlated. Numbers of plaque-forming units (PFU) were correlated with DENV-2 RNA copy number in both C6/36 cell cultures and mosquitoes. PFU were consistently lower than RNA copy number by 2-3 log(10). Midgut levels of DENV-2 RNA peaked 8 dpi and fluctuated erratically between 6 and 9 dpi. Copies of DENV-2 RNA varied significantly among infected mosquitoes at each time point. Quantitative real-time RT-PCR is a convenient and reliable method that provides new insights into virus-vector interactions.

  9. Real-Time Reciprocal Space Mapping of Nano-Islands Induced by Quantum Confinement

    NASA Astrophysics Data System (ADS)

    Hong, Hawoong; Gray, Aaron; Chiang, T.-C.

    2011-01-01

    The effects of quantum confinement have been observed pronouncedly in the island morphology of Pb thin films. The evolution of these nano-islands on Si (111)-(7 × 7) and sapphire (001) surfaces has been studied with a new X-ray diffraction method. A charge-coupled device (CCD) camera was used to collect two- and three-dimensional (2-D and 3-D, respectively) maps of the surface X-ray diffraction in real time. Large ranges of the reflectivity curves, with rocking curves at every point on the reflectivity curves, could be measured continuously in a relatively short amount of time. The abundance of information from 2-D k-space maps reveals clear changes in the growth modes of these thin Pb films. With the 3-D extension of this method, it was possible to observe the ordering of the islands. The islands maintain a nearly uniform interisland distance but lack any angular correlation. The interisland ordering is correlated well with the development of "magic" island heights caused by quantum confinement.

  10. Real-time radon monitoring at Stromboli volcano: influence of environmental parameters on 222Rn degassing

    NASA Astrophysics Data System (ADS)

    Cigolini, C.; Ripepe, M.; Poggi, P.; Laiolo, M.

    2008-12-01

    Two real-time stations for radon monitoring are currently operative at Stromboli volcano. The 222Rn electronic dosimeters are interfaced with an electronic board connected to a radiomodem for wireless data transfer (through a directional antenna) to a receiving station at the volcano observatory (COA). Radon activity data and enviromental parameters (soil temperature and atmospheric pressure) are sampled every 15 minutes and are instantaneously elaborated and transferred via web so that they can be checked in remote. Collected time series show that there is an overall inverse correlation between radon emissions and seasonal temperature variations. Signal processing analysis show that radon emissions in sectors of diffuse degassing are modulated by tidal forces as well. In addition, radon activities recorded at the summit station, located along the summit fracture zone where the gas flux is concentrated, are positively correlated with changes in atmospheric pressure and confirm the occurrence of the 'atmospheric stack effect'. It is not excluded that this process may play an active role in modulating Stromboli explosivity.

  11. [Estimation of Maximum Entrance Skin Dose during Cerebral Angiography].

    PubMed

    Kawauchi, Satoru; Moritake, Takashi; Hayakawa, Mikito; Hamada, Yusuke; Sakuma, Hideyuki; Yoda, Shogo; Satoh, Masayuki; Sun, Lue; Koguchi, Yasuhiro; Akahane, Keiichi; Chida, Koichi; Matsumaru, Yuji

    2015-09-01

    Using radio-photoluminescence glass dosimeter, we measured the entrance skin dose (ESD) in 46 cases and analyzed the correlations between maximum ESD and angiographic parameters [total fluoroscopic time (TFT); number of digital subtraction angiography (DSA) frames, air kerma at the interventional reference point (AK), and dose-area product (DAP)] to estimate the maximum ESD in real time. Mean (± standard deviation) maximum ESD, dose of the right lens, and dose of the left lens were 431.2 ± 135.8 mGy, 33.6 ± 15.5 mGy, and 58.5 ± 35.0 mGy, respectively. Correlation coefficients (r) between maximum ESD and TFT, number of DSA frames, AK, and DAP were r=0.379 (P<0.01), r=0.702 (P<0.001), r=0.825 (P<0.001), and r=0.709 (P<0.001), respectively. AK was identified as the most useful parameter for real-time prediction of maximum ESD. This study should contribute to the development of new diagnostic reference levels in our country.

  12. Real time monitoring of water distribution in an operando fuel cell during transient states

    NASA Astrophysics Data System (ADS)

    Martinez, N.; Peng, Z.; Morin, A.; Porcar, L.; Gebel, G.; Lyonnard, S.

    2017-10-01

    The water distribution of an operating proton exchange membrane fuel cell (PEMFC) was monitored in real time by using Small Angle Neutron Scattering (SANS). The formation of liquid water was obtained simultaneously with the evolution of the water content inside the membrane. Measurements were performed when changing current with a time resolution of 10 s, providing insights on the kinetics of water management prior to the stationary phase. We confirmed that water distribution is strongly heterogeneous at the scale at of the whole Membrane Electrode Assembly. As already reported, at the local scale there is no straightforward link between the amounts of water present inside and outside the membrane. However, we show that the temporal evolutions of these two parameters are strongly correlated. In particular, the local membrane water content is nearly instantaneously correlated to the total liquid water content, whether it is located at the anode or cathode side. These results can help in optimizing 3D stationary diphasic models used to predict PEMFC water distribution.

  13. Rainfall estimation for real time flood monitoring using geostationary meteorological satellite data

    NASA Astrophysics Data System (ADS)

    Veerakachen, Watcharee; Raksapatcharawong, Mongkol

    2015-09-01

    Rainfall estimation by geostationary meteorological satellite data provides good spatial and temporal resolutions. This is advantageous for real time flood monitoring and warning systems. However, a rainfall estimation algorithm developed in one region needs to be adjusted for another climatic region. This work proposes computationally-efficient rainfall estimation algorithms based on an Infrared Threshold Rainfall (ITR) method calibrated with regional ground truth. Hourly rain gauge data collected from 70 stations around the Chao-Phraya river basin were used for calibration and validation of the algorithms. The algorithm inputs were derived from FY-2E satellite observations consisting of infrared and water vapor imagery. The results were compared with the Global Satellite Mapping of Precipitation (GSMaP) near real time product (GSMaP_NRT) using the probability of detection (POD), root mean square error (RMSE) and linear correlation coefficient (CC) as performance indices. Comparison with the GSMaP_NRT product for real time monitoring purpose shows that hourly rain estimates from the proposed algorithm with the error adjustment technique (ITR_EA) offers higher POD and approximately the same RMSE and CC with less data latency.

  14. Real-Time Decision Making and Aggressive Behavior in Youth: A Heuristic Model of Response Evaluation and Decision (RED)

    PubMed Central

    Fontaine, Reid Griffith; Dodge, Kenneth A.

    2009-01-01

    Considerable scientific and intervention attention has been paid to judgment and decision-making systems associated with aggressive behavior in youth. However, most empirical studies have investigated social-cognitive correlates of stable child and adolescent aggressiveness, and less is known about real-time decision making to engage in aggressive behavior. A model of real-time decision making must incorporate both impulsive actions and rational thought. The present paper advances a process model (response evaluation and decision; RED) of real-time behavioral judgments and decision making in aggressive youths with mathematic representations that may be used to quantify response strength. These components are a heuristic to describe decision making, though it is doubtful that individuals always mentally complete these steps. RED represents an organization of social–cognitive operations believed to be active during the response decision step of social information processing. The model posits that RED processes can be circumvented through impulsive responding. This article provides a description and integration of thoughtful, rational decision making and nonrational impulsivity in aggressive behavioral interactions. PMID:20802851

  15. Real-Time Decision Making and Aggressive Behavior in Youth: A Heuristic Model of Response Evaluation and Decision (RED).

    PubMed

    Fontaine, Reid Griffith; Dodge, Kenneth A

    2006-11-01

    Considerable scientific and intervention attention has been paid to judgment and decision-making systems associated with aggressive behavior in youth. However, most empirical studies have investigated social-cognitive correlates of stable child and adolescent aggressiveness, and less is known about real-time decision making to engage in aggressive behavior. A model of real-time decision making must incorporate both impulsive actions and rational thought. The present paper advances a process model (response evaluation and decision; RED) of real-time behavioral judgments and decision making in aggressive youths with mathematic representations that may be used to quantify response strength. These components are a heuristic to describe decision making, though it is doubtful that individuals always mentally complete these steps. RED represents an organization of social-cognitive operations believed to be active during the response decision step of social information processing. The model posits that RED processes can be circumvented through impulsive responding. This article provides a description and integration of thoughtful, rational decision making and nonrational impulsivity in aggressive behavioral interactions.

  16. An efficient ASIC implementation of 16-channel on-line recursive ICA processor for real-time EEG system.

    PubMed

    Fang, Wai-Chi; Huang, Kuan-Ju; Chou, Chia-Ching; Chang, Jui-Chung; Cauwenberghs, Gert; Jung, Tzyy-Ping

    2014-01-01

    This is a proposal for an efficient very-large-scale integration (VLSI) design, 16-channel on-line recursive independent component analysis (ORICA) processor ASIC for real-time EEG system, implemented with TSMC 40 nm CMOS technology. ORICA is appropriate to be used in real-time EEG system to separate artifacts because of its highly efficient and real-time process features. The proposed ORICA processor is composed of an ORICA processing unit and a singular value decomposition (SVD) processing unit. Compared with previous work [1], this proposed ORICA processor has enhanced effectiveness and reduced hardware complexity by utilizing a deeper pipeline architecture, shared arithmetic processing unit, and shared registers. The 16-channel random signals which contain 8-channel super-Gaussian and 8-channel sub-Gaussian components are used to analyze the dependence of the source components, and the average correlation coefficient is 0.95452 between the original source signals and extracted ORICA signals. Finally, the proposed ORICA processor ASIC is implemented with TSMC 40 nm CMOS technology, and it consumes 15.72 mW at 100 MHz operating frequency.

  17. Aortic valve type and calcification as assessed by transthoracic and transoesophageal echocardiography.

    PubMed

    Yousry, Mohamed; Rickenlund, Anette; Petrini, Johan; Jenner, Jonas; Liska, Jan; Eriksson, Per; Franco-Cereceda, Anders; Eriksson, Maria J; Caidahl, Kenneth

    2015-07-01

    Aortic valve calcification (AVC) may predict poor outcome. Bicuspid aortic valve (BAV) leads to several haemodynamic changes accelerating the progress of aortic valve (AV) disease. To compare the diagnostic accuracy of transoesophageal echocardiography (TEE) and transthoracic echocardiography (TTE) in the assessment of aortic valve phenotype and degree of AVC, with intra-operative evaluation as a reference. We examined 169 patients (median age 65 years, 51 women) without significant coronary artery disease undergoing AV and/or aortic root surgery. TTE was performed within a week prior to surgery and TEE at the time of surgery. Compared with surgical AVC assessment, visual evaluation using a 5-grade scoring system and real-time images showed a higher correlation (TTE r = 0·83 and TEE r = 0·82) than visual (TTE r = 0·64 and TEE 0·63) or grey scale mean (GSMn) (TTE r = 0·63 and TEE r = 0·52) assessment of end-diastolic still frames. AVC assessment using real-time images showed high intraclass correlation coefficients (TTE 0·94 and TEE 0·93). With regard to BAV, TEE was superior to TTE with a higher interobserver agreement, sensitivity and specificity (0·86, 92% and 94% versus 0·57, 77% and 82%, respectively). Semi-quantitative AVC assessment of real-time cine loops from both TEE and TTE correlated well with intra-operative evaluation of AVC. Applying a predefined scoring system for AVC evaluation assures a high interobserver correlation. TEE was superior to TTE for evaluation of valve phenotype and should be considered when a diagnosis of BAV is clinically important. © 2014 The Authors. Clinical Physiology and Functional Imaging published by John Wiley & Sons Ltd on behalf of Scandinavian Society of Clinical Physiology and Nuclear Medicine.

  18. Relationship between Cough-Associated Changes in CSF Flow and Disease Severity in Chiari I Malformation: An Exploratory Study Using Real-Time MRI.

    PubMed

    Bezuidenhout, A F; Khatami, D; Heilman, C B; Kasper, E M; Patz, S; Madan, N; Zhao, Y; Bhadelia, R A

    2018-05-10

    Currently no quantitative objective test exists to determine disease severity in a patient with Chiari I malformation. Our aim was to correlate disease severity in symptomatic patients with Chiari I malformation with cough-associated changes in CSF flow as measured with real-time MR imaging. Thirteen symptomatic patients with Chiari I malformation (tonsillar herniation of ≥5 mm) were prospectively studied. A real-time, flow-sensitized pencil-beam MR imaging scan was used to measure CSF stroke volume during rest and immediately following coughing and relaxation periods (total scan time, 90 seconds). Multiple posterior fossa and craniocervical anatomic measurements were also obtained. Patients were classified into 2 groups by neurosurgeons blinded to MR imaging measurements: 1) nonspecific Chiari I malformation (5/13)-Chiari I malformation with nonspecific symptoms like non-cough-related or mild occasional cough-related headache, neck pain, dizziness, paresthesias, and/or trouble swallowing; 2) specific Chiari I malformation (8/13)-patients with Chiari I malformation with specific symptoms and/or objective findings like severe cough-related headache, myelopathy, syringomyelia, and muscle atrophy. The Spearman correlation was used to determine correlations between MR imaging measurements and disease severity, and both groups were also compared using a Mann-Whitney U test. There was a significant negative correlation between the percentage change in CSF stroke volume (resting to postcoughing) and Chiari I malformation disease severity ( R = 0.59; P = .03). Mann-Whitney comparisons showed the percentage change in CSF stroke volume (resting to postcoughing) to be significantly different between patient groups ( P = .04). No other CSF flow measurement or anatomic measure was significantly different between the groups. Our exploratory study suggests that assessment of CSF flow response to a coughing challenge has the potential to become a valuable objective noninvasive test for clinical assessment of disease severity in patients with Chiari I malformation. © 2018 by American Journal of Neuroradiology.

  19. Measurement of real-time tissue elastography in a phantom model and comparison with transient elastography in pediatric patients with liver diseases.

    PubMed

    Schenk, Jens-Peter; Alzen, Gerhard; Klingmüller, Volker; Teufel, Ulrike; El Sakka, Saroa; Engelmann, Guido; Selmi, Buket

    2014-01-01

    We aimed to determine the comparability of real-time tissue elastography (RTE) and transient elastography (TE) in pediatric patients with liver diseases. RTE was performed on the Elasticity QA Phantom Model 049 (Computerized Imaging Reference Systems Company Inc., Norfolk, Virginia, USA), which has five areas with different levels of stiffness. RTE measurements of relative stiffness (MEAN [mean value of tissue elasticity], AREA [% of blue color-coded stiffer tissue]) in the phantom were compared with the phantom stiffness specified in kPa (measurement unit of TE). RTE and TE were performed on 147 pediatric patients with various liver diseases. A total of 109 measurements were valid. The participants had following diseases: metabolic liver disease (n=25), cystic fibrosis (n=20), hepatopathy of unknown origin (n=11), autoimmune hepatitis (n=12), Wilson's disease (n=11), and various liver parenchyma alterations (n=30). Correlations between RTE and TE measurements in the patients were calculated. In addition, RTE was performed on a control group (n=30), and the RTE values between the patient and control groups were compared. The RTE parameters showed good correlation in the phantom model with phantom stiffness (MEAN/kPa, r=-0.97; AREA/kPa, r=0.98). However, the correlation of RTE and TE was weak in the patient group (MEAN/kPa, r=-0.23; AREA/kPa, r=0.24). A significant difference was observed between the patient and control groups (MEAN, P = 5.32 e-7; AREA, P = 1.62 e-6). In the phantom model, RTE was correlated with kPa, confirming the presumed comparability of the methods. However, there was no direct correlation between RTE and TE in patients with defined liver diseases under real clinical conditions.

  20. SGR 1822-1606: Constant Spin Period

    NASA Astrophysics Data System (ADS)

    Serim, M.; Baykal, A.; Inam, S. C.

    2011-08-01

    We have analyzed light curve of the new source SGR 1822-1606 (Cummings et al. GCN 12159) using the real time data of RXTE observations. We have extracted light curve for 11 pointings with a time span of about 20 days and employed pulse timing analysis using the harmonic representation of pulses. Using the cross correlation of harmonic representation of pulses, we have obtained pulse arrival times.

  1. Real-time and imaginary-time quantum hierarchal Fokker-Planck equations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tanimura, Yoshitaka, E-mail: tanimura@kuchem.kyoto-u.ac.jp

    2015-04-14

    We consider a quantum mechanical system represented in phase space (referred to hereafter as “Wigner space”), coupled to a harmonic oscillator bath. We derive quantum hierarchal Fokker-Planck (QHFP) equations not only in real time but also in imaginary time, which represents an inverse temperature. This is an extension of a previous work, in which we studied a spin-boson system, to a Brownian system. It is shown that the QHFP in real time obtained from a correlated thermal equilibrium state of the total system possesses the same form as those obtained from a factorized initial state. A modified terminator for themore » hierarchal equations of motion is introduced to treat the non-Markovian case more efficiently. Using the imaginary-time QHFP, numerous thermodynamic quantities, including the free energy, entropy, internal energy, heat capacity, and susceptibility, can be evaluated for any potential. These equations allow us to treat non-Markovian, non-perturbative system-bath interactions at finite temperature. Through numerical integration of the real-time QHFP for a harmonic system, we obtain the equilibrium distributions, the auto-correlation function, and the first- and second-order response functions. These results are compared with analytically exact results for the same quantities. This provides a critical test of the formalism for a non-factorized thermal state and elucidates the roles of fluctuation, dissipation, non-Markovian effects, and system-bath coherence. Employing numerical solutions of the imaginary-time QHFP, we demonstrate the capability of this method to obtain thermodynamic quantities for any potential surface. It is shown that both types of QHFP equations can produce numerical results of any desired accuracy. The FORTRAN source codes that we developed, which allow for the treatment of Wigner space dynamics with any potential form (TanimuranFP15 and ImTanimuranFP15), are provided as the supplementary material.« less

  2. Real-time reconstruction of three-dimensional brain surface MR image using new volume-surface rendering technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Watanabe, T.; Momose, T.; Oku, S.

    It is essential to obtain realistic brain surface images, in which sulci and gyri are easily recognized, when examining the correlation between functional (PET or SPECT) and anatomical (MRI) brain studies. The volume rendering technique (VRT) is commonly employed to make three-dimensional (3D) brain surface images. This technique, however, takes considerable time to make only one 3D image. Therefore it has not been practical to make the brain surface images in arbitrary directions on a real-time basis using ordinary work stations or personal computers. The surface rendering technique (SRT), on the other hand, is much less computationally demanding, but themore » quality of resulting images is not satisfactory for our purpose. A new computer algorithm has been developed to make 3D brain surface MR images very quickly using a volume-surface rendering technique (VSRT), in which the quality of resulting images is comparable to that of VRT and computation time to SRT. In VSRT the process of volume rendering is done only once to the direction of the normal vector of each surface point, rather than each time a new view point is determined as in VRT. Subsequent reconstruction of the 3D image uses a similar algorithm to that of SRT. Thus we can obtain brain surface MR images of sufficient quality viewed from any direction on a real-time basis using an easily available personal computer (Macintosh Quadra 800). The calculation time to make a 3D image is less than 1 sec. in VSRT, while that is more than 15 sec. in the conventional VRT. The difference of resulting image quality between VSRT and VRT is almost imperceptible. In conclusion, our new technique for real-time reconstruction of 3D brain surface MR image is very useful and practical in the functional and anatomical correlation study.« less

  3. Using Citizen Science and Crowdsourcing via Aurorasaurus as a Near Real Time Data Source for Space Weather Applications

    NASA Astrophysics Data System (ADS)

    MacDonald, E.; Heavner, M.; Hall, M.; Tapia, A.; Lalone, N.; Clayon, J.; Case, N.

    2014-12-01

    Aurorasaurus is on the cutting edge of space science, citizen science, and computer science simultaneously with the broad goals to develop a real-time citizen science network, educate the general public about the northern lights, and revolutionize real-time space weather nowcasting of the aurora for the public. We are currently in the first solar maximum with social media, which enables the technological roots to connect users, citizen scientists, and professionals around a shared global, rare interest. We will introduce the project which has been in a prototype mode since 2012 and recently relaunched with a new mobile and web presence and active campaigns. We will showcase the interdisciplinary advancements which include a more educated public, disaster warning system applications, and improved real-time ground truth data including photographs and observations of the Northern Lights. We will preview new data which validates the proof of concept for significant improvements in real-time space weather nowcasting. Our aim is to provide better real-time notifications of the visibility of the Northern Lights to the interested public via the combination of noisy crowd-sourced ground truth with noisy satellite-based predictions. The latter data are available now but are often delivered with significant jargon and uncertainty, thus reliable, timely interpretation of such forecasts by the public are problematic. The former data show real-time characteristic significant rises (in tweets for instance) that correlate with other non-real-time indices of auroral activity (like the Kp index). We will discuss the source of 'noise' in each data source. Using citizen science as a platform to provide a basis for deeper understanding is one goal; secondly we want to improve understanding of and appreciation for the dynamics and beauty of the Northern Lights by the public and scientists alike.

  4. The potential of lipopolysaccharide as a real-time biomarker of bacterial contamination in marine bathing water.

    PubMed

    Sattar, Anas A; Jackson, Simon K; Bradley, Graham

    2014-03-01

    The use of total lipopolysaccharide (LPS) as a rapid biomarker for bacterial pollution was investigated at a bathing and surfing beach during the UK bathing season. The levels of faecal indicator bacteria Escherichia coli (E. coli), the Gram-positive enterococci, and organisms commonly associated with faecal material, such as total coliforms and Bacteroides, were culturally monitored over four months to include a period of heavy rainfall and concomitant pollution. Endotoxin measurement was performed using a kinetic Limulus Amebocyte Lysate (LAL) assay and found to correlate well with all indicators. Levels of LPS in excess of 50 Endotoxin Units (EU) mL(-1) were found to correlate with water that was unsuitable for bathing under the current European regulations. Increases in total LPS, mainly from Gram-negative indicator bacteria, are thus a potential real-time, qualitative method for testing bacterial quality of bathing waters.

  5. Real-Time Unsteady Loads Measurements Using Hot-Film Sensors

    NASA Technical Reports Server (NTRS)

    Mangalam, Arun S.; Moes, Timothy R.

    2004-01-01

    Several flight-critical aerodynamic problems such as buffet, flutter, stall, and wing rock are strongly affected or caused by abrupt changes in unsteady aerodynamic loads and moments. Advanced sensing and flow diagnostic techniques have made possible simultaneous identification and tracking, in realtime, of the critical surface, viscosity-related aerodynamic phenomena under both steady and unsteady flight conditions. The wind tunnel study reported here correlates surface hot-film measurements of leading edge stagnation point and separation point, with unsteady aerodynamic loads on a NACA 0015 airfoil. Lift predicted from the correlation model matches lift obtained from pressure sensors for an airfoil undergoing harmonic pitchup and pitchdown motions. An analytical model was developed that demonstrates expected stall trends for pitchup and pitchdown motions. This report demonstrates an ability to obtain unsteady aerodynamic loads in real time, which could lead to advances in air vehicle safety, performance, ride-quality, control, and health management.

  6. The Geography of Happiness: Connecting Twitter Sentiment and Expression, Demographics, and Objective Characteristics of Place

    PubMed Central

    Mitchell, Lewis; Frank, Morgan R.; Harris, Kameron Decker; Dodds, Peter Sheridan; Danforth, Christopher M.

    2013-01-01

    We conduct a detailed investigation of correlations between real-time expressions of individuals made across the United States and a wide range of emotional, geographic, demographic, and health characteristics. We do so by combining (1) a massive, geo-tagged data set comprising over 80 million words generated in 2011 on the social network service Twitter and (2) annually-surveyed characteristics of all 50 states and close to 400 urban populations. Among many results, we generate taxonomies of states and cities based on their similarities in word use; estimate the happiness levels of states and cities; correlate highly-resolved demographic characteristics with happiness levels; and connect word choice and message length with urban characteristics such as education levels and obesity rates. Our results show how social media may potentially be used to estimate real-time levels and changes in population-scale measures such as obesity rates. PMID:23734200

  7. Comparison of Solar and Wind Power Output and Correlation with Real-Time Pricing

    NASA Astrophysics Data System (ADS)

    Hoepfl, Kathryn E.; Compaan, Alvin D.; Solocha, Andrew

    2011-03-01

    This study presents a method that can be used to determine the least volatile power output of a wind and solar hybrid energy system in which wind and solar systems have the same peak power. Hourly data for wind and PV systems in Northwest Ohio are used to show that a combination of both types of sustainable energy sources produces a more stable power output and would be more valuable to the grid than either individually. This method could be used to determine the ideal ratio in any part of the country and should help convince electric utility companies to bring more renewable generation online. This study also looks at real-time market pricing and how each system (solar, wind, and hybrid) correlates with 2009 hourly pricing from the Midwest Interconnect. KEH acknowledges support from the NSF-REU grant PHY-1004649 to the Univ. of Toledo and Garland Energy Systems/Ohio Department of Development.

  8. Design considerations for a real-time ocular counterroll instrument

    NASA Technical Reports Server (NTRS)

    Hatamian, M.; Anderson, D. J.

    1983-01-01

    A real-time algorithm for measuring three-dimensional movement of the human eye, especially torsional movement, is presented. As its input, the system uses images of the eyeball taken at video rate. The amount of horizontal and vertical movement is extracted using a pupil tracking technique. The torsional movement is then measured by computing the discrete cross-correlation function between the circular samples of successive images of the iris patterns and searching for the position of the peak of the function. A local least square interpolation around the peak of the cross-correlation function is used to produce nearly unbiased estimates of torsion angle with accuracy of about 3-4 arcmin. Accuracies of better than 0.03 deg are achievable in torsional measurement with SNR higher than 36 dB. Horizontal and vertical rotations of up to + or - 13 deg can occur simultaneously with torsion without introducing any appreciable error in the counterrolling measurement process.

  9. The geography of happiness: connecting twitter sentiment and expression, demographics, and objective characteristics of place.

    PubMed

    Mitchell, Lewis; Frank, Morgan R; Harris, Kameron Decker; Dodds, Peter Sheridan; Danforth, Christopher M

    2013-01-01

    We conduct a detailed investigation of correlations between real-time expressions of individuals made across the United States and a wide range of emotional, geographic, demographic, and health characteristics. We do so by combining (1) a massive, geo-tagged data set comprising over 80 million words generated in 2011 on the social network service Twitter and (2) annually-surveyed characteristics of all 50 states and close to 400 urban populations. Among many results, we generate taxonomies of states and cities based on their similarities in word use; estimate the happiness levels of states and cities; correlate highly-resolved demographic characteristics with happiness levels; and connect word choice and message length with urban characteristics such as education levels and obesity rates. Our results show how social media may potentially be used to estimate real-time levels and changes in population-scale measures such as obesity rates.

  10. A dual near-infrared and dielectric spectroscopies strategy to monitor populations of Chinese hamster ovary cells in bioreactor.

    PubMed

    Courtès, Franck; Ebel, Bruno; Guédon, Emmanuel; Marc, Annie

    2016-05-01

    to develop a new strategy combining near-infrared (NIR) and dielectric spectroscopies for real-time monitoring and in-depth characterizing populations of Chinese hamster ovary cells throughout cultures performed in bioreactors. Spectral data processing was based on off-line analyses of the cells, including trypan blue exclusion method, and lactate dehydrogenase activity (LDH). Viable cell density showed a linear correlation with permittivity up to 6 × 10(6) cells ml(-1), while a logarithmic correlation was found between non-lysed dead cell density and conductivity up to 10(7) cells ml(-1). Additionally, partial least square technique was used to develop a calibration model of the supernatant LDH activity based on online NIR spectra with a RMSEC of 55 U l(-1). Considering the LDH content of viable cells measured to be 110 U per 10(9) cells, the lysed dead cell density could be then estimated. These calibration models provided real-time prediction accuracy (R(2) ≥ 0.95) for the three types of cell populations. The high potential of a dual spectroscopy strategy to enhance the online bioprocesses characterization is demonstrated since it allows the simultaneous determination of viable, dead and lysed cell populations in real time.

  11. Investigation of Legionella Contamination in Bath Water Samples by Culture, Amoebic Co-Culture, and Real-Time Quantitative PCR Methods.

    PubMed

    Edagawa, Akiko; Kimura, Akio; Kawabuchi-Kurata, Takako; Adachi, Shinichi; Furuhata, Katsunori; Miyamoto, Hiroshi

    2015-10-19

    We investigated Legionella contamination in bath water samples, collected from 68 bathing facilities in Japan, by culture, culture with amoebic co-culture, real-time quantitative PCR (qPCR), and real-time qPCR with amoebic co-culture. Using the conventional culture method, Legionella pneumophila was detected in 11 samples (11/68, 16.2%). Contrary to our expectation, the culture method with the amoebic co-culture technique did not increase the detection rate of Legionella (4/68, 5.9%). In contrast, a combination of the amoebic co-culture technique followed by qPCR successfully increased the detection rate (57/68, 83.8%) compared with real-time qPCR alone (46/68, 67.6%). Using real-time qPCR after culture with amoebic co-culture, more than 10-fold higher bacterial numbers were observed in 30 samples (30/68, 44.1%) compared with the same samples without co-culture. On the other hand, higher bacterial numbers were not observed after propagation by amoebae in 32 samples (32/68, 47.1%). Legionella was not detected in the remaining six samples (6/68, 8.8%), irrespective of the method. These results suggest that application of the amoebic co-culture technique prior to real-time qPCR may be useful for the sensitive detection of Legionella from bath water samples. Furthermore, a combination of amoebic co-culture and real-time qPCR might be useful to detect viable and virulent Legionella because their ability to invade and multiply within free-living amoebae is considered to correlate with their pathogenicity for humans. This is the first report evaluating the efficacy of the amoebic co-culture technique for detecting Legionella in bath water samples.

  12. Investigation of Legionella Contamination in Bath Water Samples by Culture, Amoebic Co-Culture, and Real-Time Quantitative PCR Methods

    PubMed Central

    Edagawa, Akiko; Kimura, Akio; Kawabuchi-Kurata, Takako; Adachi, Shinichi; Furuhata, Katsunori; Miyamoto, Hiroshi

    2015-01-01

    We investigated Legionella contamination in bath water samples, collected from 68 bathing facilities in Japan, by culture, culture with amoebic co-culture, real-time quantitative PCR (qPCR), and real-time qPCR with amoebic co-culture. Using the conventional culture method, Legionella pneumophila was detected in 11 samples (11/68, 16.2%). Contrary to our expectation, the culture method with the amoebic co-culture technique did not increase the detection rate of Legionella (4/68, 5.9%). In contrast, a combination of the amoebic co-culture technique followed by qPCR successfully increased the detection rate (57/68, 83.8%) compared with real-time qPCR alone (46/68, 67.6%). Using real-time qPCR after culture with amoebic co-culture, more than 10-fold higher bacterial numbers were observed in 30 samples (30/68, 44.1%) compared with the same samples without co-culture. On the other hand, higher bacterial numbers were not observed after propagation by amoebae in 32 samples (32/68, 47.1%). Legionella was not detected in the remaining six samples (6/68, 8.8%), irrespective of the method. These results suggest that application of the amoebic co-culture technique prior to real-time qPCR may be useful for the sensitive detection of Legionella from bath water samples. Furthermore, a combination of amoebic co-culture and real-time qPCR might be useful to detect viable and virulent Legionella because their ability to invade and multiply within free-living amoebae is considered to correlate with their pathogenicity for humans. This is the first report evaluating the efficacy of the amoebic co-culture technique for detecting Legionella in bath water samples. PMID:26492259

  13. Real-time optical correlator using computer-generated holographic filter on a liquid crystal light valve

    NASA Technical Reports Server (NTRS)

    Chao, Tien-Hsin; Yu, Jeffrey

    1990-01-01

    Limitations associated with the binary phase-only filter often used in optical correlators are presently circumvented in the writing of complex-valued data on a gray-scale spatial light modulator through the use of a computer-generated hologram (CGH) algorithm. The CGH encodes complex-valued data into nonnegative real CGH data in such a way that it may be encoded in any of the available gray-scale spatial light modulators. A CdS liquid-crystal light valve is used for the complex-valued CGH encoding; computer simulations and experimental results are compared, and the use of such a CGH filter as the synapse hologram in a holographic optical neural net is discussed.

  14. Real-time vehicle emissions monitoring using a compact LiDAR system and conventional instruments: first results of an experimental campaign in a suburban area in southern Italy

    NASA Astrophysics Data System (ADS)

    Parracino, Stefano; Richetta, Maria; Gelfusa, Michela; Malizia, Andrea; Bellecci, Carlo; De Leo, Leonardo; Perrimezzi, Carlo; Fin, Alessandro; Forin, Marco; Giappicucci, Francesca; Grion, Massimo; Marchese, Giuseppe; Gaudio, Pasquale

    2016-10-01

    Urban air pollution causes deleterious effects on human health and the environment. To meet stringent standards imposed by the European Commission, advanced measurement methods are required. Remote sensing techniques, such as light detection and ranging (LiDAR), can be a valuable option for evaluating particulate matter (PM), emitted by vehicles in urban traffic, with high sensitivity and in shorter time intervals. Since air quality problems persist not only in large urban areas, a measuring campaign was specifically performed in a suburban area of Crotone, Italy, using both a compact LiDAR system and conventional instruments for real-time vehicle emissions monitoring along a congested road. First results reported in this paper show a strong dependence between variations of LiDAR backscattering signals and traffic-related air pollution levels. Moreover, time-resolved LiDAR data averaged in limited regions, directly above conventional monitoring stations at the border of an intersection, were found to be linearly correlated to the PM concentration levels with a correlation coefficient between 0.75 and 0.84.

  15. Dynamic Singularity Spectrum Distribution of Sea Clutter

    NASA Astrophysics Data System (ADS)

    Xiong, Gang; Yu, Wenxian; Zhang, Shuning

    2015-12-01

    The fractal and multifractal theory have provided new approaches for radar signal processing and target-detecting under the background of ocean. However, the related research mainly focuses on fractal dimension or multifractal spectrum (MFS) of sea clutter. In this paper, a new dynamic singularity analysis method of sea clutter using MFS distribution is developed, based on moving detrending analysis (DMA-MFSD). Theoretically, we introduce the time information by using cyclic auto-correlation of sea clutter. For transient correlation series, the instantaneous singularity spectrum based on multifractal detrending moving analysis (MF-DMA) algorithm is calculated, and the dynamic singularity spectrum distribution of sea clutter is acquired. In addition, we analyze the time-varying singularity exponent ranges and maximum position function in DMA-MFSD of sea clutter. For the real sea clutter data, we analyze the dynamic singularity spectrum distribution of real sea clutter in level III sea state, and conclude that the radar sea clutter has the non-stationary and time-varying scale characteristic and represents the time-varying singularity spectrum distribution based on the proposed DMA-MFSD method. The DMA-MFSD will also provide reference for nonlinear dynamics and multifractal signal processing.

  16. Application of troposphere model from NWP and GNSS data into real-time precise positioning

    NASA Astrophysics Data System (ADS)

    Wilgan, Karina; Hadas, Tomasz; Kazmierski, Kamil; Rohm, Witold; Bosy, Jaroslaw

    2016-04-01

    The tropospheric delay empirical models are usually functions of meteorological parameters (temperature, pressure and humidity). The application of standard atmosphere parameters or global models, such as GPT (global pressure/temperature) model or UNB3 (University of New Brunswick, version 3) model, may not be sufficient, especially for positioning in non-standard weather conditions. The possible solution is to use regional troposphere models based on real-time or near-real time measurements. We implement a regional troposphere model into the PPP (Precise Point Positioning) software GNSS-WARP (Wroclaw Algorithms for Real-time Positioning) developed at Wroclaw University of Environmental and Life Sciences. The software is capable of processing static and kinematic multi-GNSS data in real-time and post-processing mode and takes advantage of final IGS (International GNSS Service) products as well as IGS RTS (Real-Time Service) products. A shortcoming of PPP technique is the time required for the solution to converge. One of the reasons is the high correlation among the estimated parameters: troposphere delay, receiver clock offset and receiver height. To efficiently decorrelate these parameters, a significant change in satellite geometry is required. Alternative solution is to introduce the external high-quality regional troposphere delay model to constrain troposphere estimates. The proposed model consists of zenith total delays (ZTD) and mapping functions calculated from meteorological parameters from Numerical Weather Prediction model WRF (Weather Research and Forecasting) and ZTDs from ground-based GNSS stations using the least-squares collocation software COMEDIE (Collocation of Meteorological Data for Interpretation and Estimation of Tropospheric Pathdelays) developed at ETH Zurich.

  17. Methods and Measurements in Real-Time Air Traffic Control System Simulation

    DTIC Science & Technology

    1983-04-01

    Percent of Variance Consumed by Factors 28 7 Correlations Between ABM II Factor Scores and SE14 1 30 Sector-Density Cell -Based Facter Scores 8 SEX I Cell ...runs for each of 31 subjects under each of 6 sector geometry-traffic density combinations ( cells ). Initial analyses, involving correlations between the...two runs in each cell , indicated very low correlations between the replicates. It was decided that before going further it would be best to conduct a

  18. Comparing synthetic imagery with real imagery for visible signature analysis: human observer results

    NASA Astrophysics Data System (ADS)

    Culpepper, Joanne B.; Richards, Noel; Madden, Christopher S.; Winter, Neal; Wheaton, Vivienne C.

    2017-10-01

    Synthetic imagery could potentially enhance visible signature analysis by providing a wider range of target images in differing environmental conditions than would be feasible to collect in field trials. Achieving this requires a method for generating synthetic imagery that is both verified to be realistic and produces the same visible signature analysis results as real images. Is target detectability as measured by image metrics the same for real images and synthetic images of the same scene? Is target detectability as measured by human observer trials the same for real images and synthetic images of the same scene, and how realistic do the synthetic images need to be? In this paper we present the results of a small scale exploratory study on the second question: a photosimulation experiment conducted using digital photographs and synthetic images generated of the same scene. Two sets of synthetic images were created: a high fidelity set created using an image generation tool, E-on Vue, and a low fidelity set created using a gaming engine, Unity 3D. The target detection results obtained using digital photographs were compared with those obtained using the two sets of synthetic images. There was a moderate correlation between the high fidelity synthetic image set and the real images in both the probability of correct detection (Pd: PCC = 0.58, SCC = 0.57) and mean search time (MST: PCC = 0.63, SCC = 0.61). There was no correlation between the low fidelity synthetic image set and the real images for the Pd, but a moderate correlation for MST (PCC = 0.67, SCC = 0.55).

  19. Strain expansion-reduction approach

    NASA Astrophysics Data System (ADS)

    Baqersad, Javad; Bharadwaj, Kedar

    2018-02-01

    Validating numerical models are one of the main aspects of engineering design. However, correlating million degrees of freedom of numerical models to the few degrees of freedom of test models is challenging. Reduction/expansion approaches have been traditionally used to match these degrees of freedom. However, the conventional reduction/expansion approaches are only limited to displacement, velocity or acceleration data. While in many cases only strain data are accessible (e.g. when a structure is monitored using strain-gages), the conventional approaches are not capable of expanding strain data. To bridge this gap, the current paper outlines a reduction/expansion technique to reduce/expand strain data. In the proposed approach, strain mode shapes of a structure are extracted using the finite element method or the digital image correlation technique. The strain mode shapes are used to generate a transformation matrix that can expand the limited set of measurement data. The proposed approach can be used to correlate experimental and analytical strain data. Furthermore, the proposed technique can be used to expand real-time operating data for structural health monitoring (SHM). In order to verify the accuracy of the approach, the proposed technique was used to expand the limited set of real-time operating data in a numerical model of a cantilever beam subjected to various types of excitations. The proposed technique was also applied to expand real-time operating data measured using a few strain gages mounted to an aluminum beam. It was shown that the proposed approach can effectively expand the strain data at limited locations to accurately predict the strain at locations where no sensors were placed.

  20. Detection of defects in laser welding of AZ31B magnesium alloy in zero-gap lap joint configuration by a real-time spectroscopic analysis

    NASA Astrophysics Data System (ADS)

    Harooni, Masoud; Carlson, Blair; Kovacevic, Radovan

    2014-05-01

    The effect of surface oxide layer existing at the lap-joint faying surface of magnesium sheets is investigated on the keyhole dynamics of the weld pool and weld bead qualities. It is observed that by removing the oxide layer from the faying surface of the lap joint, a high quality weld can be achieved in the laser welding process. However, the presence of an oxide layer deteriorates the quality of the weld by forming pores at the interface of the two overlapped sheets. The purpose of this paper is to identify the correlation between the integrity of the weld and the interaction between the laser and material. A spectroscopy sensor was applied to detect the spectra emitted from a plasma plume during the laser welding of AZ31B magnesium alloy in a zero-gap lap joint configuration. The electron temperature was calculated by applying a Boltzmann plot method based on the detected spectra, and the correlation between the pore formation and the spectral signals was studied. The laser molten pool and the keyhole condition were monitored in real-time by a high speed charge-coupled device (CCD) camera. A green laser was used as an illumination source in order to detect the influence of the oxide layer on the dynamic behavior of the molten pool. Results revealed that the detected spectrum and weld defects had a meaningful correlation for real-time monitoring of the weld quality during laser welding of magnesium alloys.

  1. The influence of clutter on real-world scene search: evidence from search efficiency and eye movements.

    PubMed

    Henderson, John M; Chanceaux, Myriam; Smith, Tim J

    2009-01-23

    We investigated the relationship between visual clutter and visual search in real-world scenes. Specifically, we investigated whether visual clutter, indexed by feature congestion, sub-band entropy, and edge density, correlates with search performance as assessed both by traditional behavioral measures (response time and error rate) and by eye movements. Our results demonstrate that clutter is related to search performance. These results hold for both traditional search measures and for eye movements. The results suggest that clutter may serve as an image-based proxy for search set size in real-world scenes.

  2. Real-time piloted simulation of fully automatic guidance and control for rotorcraft nap-of-the-earth (NOE) flight following planned profiles

    NASA Technical Reports Server (NTRS)

    Clement, Warren F.; Gorder, Pater J.; Jewell, Wayne F.; Coppenbarger, Richard

    1990-01-01

    Developing a single-pilot all-weather NOE capability requires fully automatic NOE navigation and flight control. Innovative guidance and control concepts are being investigated to (1) organize the onboard computer-based storage and real-time updating of NOE terrain profiles and obstacles; (2) define a class of automatic anticipative pursuit guidance algorithms to follow the vertical, lateral, and longitudinal guidance commands; (3) automate a decision-making process for unexpected obstacle avoidance; and (4) provide several rapid response maneuvers. Acquired knowledge from the sensed environment is correlated with the recorded environment which is then used to determine an appropriate evasive maneuver if a nonconformity is observed. This research effort has been evaluated in both fixed-base and moving-base real-time piloted simulations thereby evaluating pilot acceptance of the automated concepts, supervisory override, manual operation, and reengagement of the automatic system.

  3. Real-time imaging of the growth-inhibitory effect of JS399-19 on Fusarium.

    PubMed

    Wollenberg, Rasmus D; Donau, Søren S; Nielsen, Thorbjørn T; Sørensen, Jens L; Giese, Henriette; Wimmer, Reinhard; Søndergaard, Teis E

    2016-11-01

    Real-time imaging was used to study the effects of a novel Fusarium-specific cyanoacrylate fungicide (JS399-19) on growth and morphology of four Fusarium sp. This fungicide targets the motor domain of type I myosin. Fusarium graminearum PH-1, Fusarium solani f. sp. pisi 77-13-4, Fusarium avenaceum IBT8464, and Fusarium avenaceum 05001, which has a K216Q amino-acid substitution at the resistance-implicated site in its myosin type I motor domain, were analyzed. Real-time imaging shows that JS399-19 inhibits fungal growth but not to the extent previously reported. The fungicide causes the hypha to become entangled and unable to extend vertically. This implies that type I myosin in Fusarium is essential for hyphal and mycelia propagation. The K216Q substitution correlates with reduced susceptibility in F. avenaceum. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Application of a molecular beacon based real-time isothermal amplification (MBRTIA) technology for simultaneous detection of Bacillus cereus and Staphylococcus aureus.

    PubMed

    Mandappa, I M; Joglekar, Prasanna; Manonmani, H K

    2015-07-01

    A multiplex real-time isothermal amplification assay was developed using molecular beacons for the detection of Bacillus cereus and Staphylococcus aureus by targeting four important virulence genes. A correlation between targeting highly accessible DNA sequences and isothermal amplification based molecular beacon efficiency and sensitivity was demonstrated using phi(Φ)29 DNA polymerase at a constant isothermal temperature of 30 °C. It was very selective and consistently detected down to 10(1) copies of DNA. The specificity and sensitivity of this assay, when tested with pure culture were high, surpassing those of currently used PCR assays for the detection of these organisms. The molecular beacon based real-time isothermal amplification (MBRTIA) assay could be carried out entirely in 96 well plates or well strips, enabling a rapid and high-throughput detection of food borne pathogens.

  5. Automated real-time structure health monitoring via signature pattern recognition

    NASA Astrophysics Data System (ADS)

    Sun, Fanping P.; Chaudhry, Zaffir A.; Rogers, Craig A.; Majmundar, M.; Liang, Chen

    1995-05-01

    Described in this paper are the details of an automated real-time structure health monitoring system. The system is based on structural signature pattern recognition. It uses an array of piezoceramic patches bonded to the structure as integrated sensor-actuators, an electric impedance analyzer for structural frequency response function acquisition and a PC for control and graphic display. An assembled 3-bay truss structure is employed as a test bed. Two issues, the localization of sensing area and the sensor temperature drift, which are critical for the success of this technique are addressed and a novel approach of providing temperature compensation using probability correlation function is presented. Due to the negligible weight and size of the solid-state sensor array and its ability to sense incipient-type damage, the system can eventually be implemented on many types of structures such as aircraft, spacecraft, large-span dome roof and steel bridges requiring multilocation and real-time health monitoring.

  6. Quantification of HIV-1 DNA using real-time recombinase polymerase amplification.

    PubMed

    Crannell, Zachary Austin; Rohrman, Brittany; Richards-Kortum, Rebecca

    2014-06-17

    Although recombinase polymerase amplification (RPA) has many advantages for the detection of pathogenic nucleic acids in point-of-care applications, RPA has not yet been implemented to quantify sample concentration using a standard curve. Here, we describe a real-time RPA assay with an internal positive control and an algorithm that analyzes real-time fluorescence data to quantify HIV-1 DNA. We show that DNA concentration and the onset of detectable amplification are correlated by an exponential standard curve. In a set of experiments in which the standard curve and algorithm were used to analyze and quantify additional DNA samples, the algorithm predicted an average concentration within 1 order of magnitude of the correct concentration for all HIV-1 DNA concentrations tested. These results suggest that quantitative RPA (qRPA) may serve as a powerful tool for quantifying nucleic acids and may be adapted for use in single-sample point-of-care diagnostic systems.

  7. Deactivation of Zeolite Catalyst H-ZSM-5 during Conversion of Methanol to Gasoline: Operando Time- and Space-Resolved X-ray Diffraction.

    PubMed

    Rojo-Gama, Daniel; Mentel, Lukasz; Kalantzopoulos, Georgios N; Pappas, Dimitrios K; Dovgaliuk, Iurii; Olsbye, Unni; Lillerud, Karl Petter; Beato, Pablo; Lundegaard, Lars F; Wragg, David S; Svelle, Stian

    2018-03-15

    The deactivation of zeolite catalyst H-ZSM-5 by coking during the conversion of methanol to hydrocarbons was monitored by high-energy space- and time-resolved operando X-ray diffraction (XRD) . Space resolution was achieved by continuous scanning along the axial length of a capillary fixed bed reactor with a time resolution of 10 s per scan. Using real structural parameters obtained from XRD, we can track the development of coke at different points in the reactor and link this to a kinetic model to correlate catalyst deactivation with structural changes occurring in the material. The "burning cigar" model of catalyst bed deactivation is directly observed in real time.

  8. Estimating serial correlation and self-similarity in financial time series-A diversification approach with applications to high frequency data

    NASA Astrophysics Data System (ADS)

    Gerlich, Nikolas; Rostek, Stefan

    2015-09-01

    We derive a heuristic method to estimate the degree of self-similarity and serial correlation in financial time series. Especially, we propagate the use of a tailor-made selection of different estimation techniques that are used in various fields of time series analysis but until now have not consequently found their way into the finance literature. Following the idea of portfolio diversification, we show that considerable improvements with respect to robustness and unbiasedness can be achieved by using a basket of estimation methods. With this methodological toolbox at hand, we investigate real market data to show that noticeable deviations from the assumptions of constant self-similarity and absence of serial correlation occur during certain periods. On the one hand, this may shed a new light on seemingly ambiguous scientific findings concerning serial correlation of financial time series. On the other hand, a proven time-changing degree of self-similarity may help to explain high-volatility clusters of stock price indices.

  9. Wind Energy System Time-domain (WEST) analyzers using hybrid simulation techniques

    NASA Technical Reports Server (NTRS)

    Hoffman, J. A.

    1979-01-01

    Two stand-alone analyzers constructed for real time simulation of the complex dynamic characteristics of horizontal-axis wind energy systems are described. Mathematical models for an aeroelastic rotor, including nonlinear aerodynamic and elastic loads, are implemented with high speed digital and analog circuitry. Models for elastic supports, a power train, a control system, and a rotor gimbal system are also included. Limited correlation efforts show good comparisons between results produced by the analyzers and results produced by a large digital simulation. The digital simulation results correlate well with test data.

  10. An interactive internet-based plate for assessing lunchtime food intake: a validation study on male employees.

    PubMed

    Svensson, Madeleine; Bellocco, Rino; Bakkman, Linda; Trolle Lagerros, Ylva

    2013-01-18

    Misreporting food intake is common because most health screenings rely on self-reports. The more accurate methods (eg, weighing food) are costly, time consuming, and impractical. We developed a new instrument for reporting food intake--an Internet-based interactive virtual food plate. The objective of this study was to validate this instrument's ability to assess lunch intake. Participants were asked to compose an ordinary lunch meal using both a virtual and a real lunch plate (with real food on a real plate). The participants ate their real lunch meals on-site. Before and after pictures of the composed lunch meals were taken. Both meals included identical food items. Participants were randomized to start with either instrument. The 2 instruments were compared using correlation and concordance measures (total energy intake, nutritional components, quantity of food, and participant characteristics). A total of 55 men (median age: 45 years, median body mass index [BMI]: 25.8 kg/m(2)) participated. We found an overall overestimation of reported median energy intake using the computer plate (3044 kJ, interquartile range [IQR] 1202 kJ) compared with the real lunch plate (2734 kJ, IQR 1051 kJ, P<.001). Spearman rank correlations and concordance correlations for energy intake and nutritional components ranged between 0.58 to 0.79 and 0.65 to 0.81, respectively. Although it slightly overestimated, our computer plate provides promising results in assessing lunch intake.

  11. An Interactive Internet-Based Plate for Assessing Lunchtime Food Intake: A Validation Study on Male Employees

    PubMed Central

    Bellocco, Rino; Bakkman, Linda; Trolle Lagerros, Ylva

    2013-01-01

    Background Misreporting food intake is common because most health screenings rely on self-reports. The more accurate methods (eg, weighing food) are costly, time consuming, and impractical. Objectives We developed a new instrument for reporting food intake—an Internet-based interactive virtual food plate. The objective of this study was to validate this instrument’s ability to assess lunch intake. Methods Participants were asked to compose an ordinary lunch meal using both a virtual and a real lunch plate (with real food on a real plate). The participants ate their real lunch meals on-site. Before and after pictures of the composed lunch meals were taken. Both meals included identical food items. Participants were randomized to start with either instrument. The 2 instruments were compared using correlation and concordance measures (total energy intake, nutritional components, quantity of food, and participant characteristics). Results A total of 55 men (median age: 45 years, median body mass index [BMI]: 25.8 kg/m2) participated. We found an overall overestimation of reported median energy intake using the computer plate (3044 kJ, interquartile range [IQR] 1202 kJ) compared with the real lunch plate (2734 kJ, IQR 1051 kJ, P<.001). Spearman rank correlations and concordance correlations for energy intake and nutritional components ranged between 0.58 to 0.79 and 0.65 to 0.81, respectively. Conclusion Although it slightly overestimated, our computer plate provides promising results in assessing lunch intake. PMID:23335728

  12. Assessing the performance of a motion tracking system based on optical joint transform correlation

    NASA Astrophysics Data System (ADS)

    Elbouz, M.; Alfalou, A.; Brosseau, C.; Ben Haj Yahia, N.; Alam, M. S.

    2015-08-01

    We present an optimized system specially designed for the tracking and recognition of moving subjects in a confined environment (such as an elderly remaining at home). In the first step of our study, we use a VanderLugt correlator (VLC) with an adapted pre-processing treatment of the input plane and a postprocessing of the correlation plane via a nonlinear function allowing us to make a robust decision. The second step is based on an optical joint transform correlation (JTC)-based system (NZ-NL-correlation JTC) for achieving improved detection and tracking of moving persons in a confined space. The proposed system has been found to have significantly superior discrimination and robustness capabilities allowing to detect an unknown target in an input scene and to determine the target's trajectory when this target is in motion. This system offers robust tracking performance of a moving target in several scenarios, such as rotational variation of input faces. Test results obtained using various real life video sequences show that the proposed system is particularly suitable for real-time detection and tracking of moving objects.

  13. Time-to-space mapping of femtosecond pulses.

    PubMed

    Nuss, M C; Li, M; Chiu, T H; Weiner, A M; Partovi, A

    1994-05-01

    We report time-to-space mapping of femtosecond light pulses in a temporal holography setup. By reading out a temporal hologram of a short optical pulse with a continuous-wave diode laser, we accurately convert temporal pulse-shape information into a spatial pattern that can be viewed with a camera. We demonstrate real-time acquisition of electric-field autocorrelation and cross correlation of femtosecond pulses with this technique.

  14. Real-Time Detection of Tsunami Ionospheric Disturbances with a Stand-Alone GNSS Receiver: An Integration of GPS and Galileo Systems

    NASA Astrophysics Data System (ADS)

    Savastano, Giorgio; Komjathy, Attila; Verkhoglyadova, Olga; Wei, Yong; Mazzoni, Augusto; Crespi, Mattia

    2017-04-01

    Tsunamis can produce gravity waves that propagate up to the ionosphere generating disturbed electron densities in the E and F regions. These ionospheric disturbances are studied in detail using ionospheric total electron content (TEC) measurements collected by continuously operating ground-based receivers from the Global Navigation Satellite Systems (GNSS). Here, we present results using a new approach, named VARION (Variometric Approach for Real-Time Ionosphere Observation), and for the first time, we estimate slant TEC (sTEC) variations in a real-time scenario from GPS and Galileo constellations. Specifically, we study the 2016 New Zealand tsunami event using GNSS receivers with multi-constellation tracking capabilities located in the Pacific region. We compare sTEC estimates obtained using GPS and Galileo constellations. The efficiency of the real-time sTEC estimation using the VARION algorithm has been demonstrated for the 2012 Haida Gwaii tsunami event. TEC variations induced by the tsunami event are computed using 56 GPS receivers in Hawai'i. We observe TEC perturbations with amplitudes up to 0.25 TEC units and traveling ionospheric disturbances moving away from the epicenter at a speed of about 316 m/s. We present comparisons with the real-time tsunami model MOST (Method of Splitting Tsunami) provided by the NOAA Center for Tsunami Research. We observe variations in TEC that correlate well in time and space with the propagating tsunami waves. We conclude that the integration of different satellite constellations is a crucial step forward to increasing the reliability of real-time tsunami detection systems using ground-based GNSS receivers as an augmentation to existing tsunami early warning systems.

  15. Active pain coping is associated with the response in real-time fMRI neurofeedback during pain.

    PubMed

    Emmert, Kirsten; Breimhorst, Markus; Bauermann, Thomas; Birklein, Frank; Rebhorn, Cora; Van De Ville, Dimitri; Haller, Sven

    2017-06-01

    Real-time functional magnetic resonance imaging (rt-fMRI) neurofeedback is used as a tool to gain voluntary control of activity in various brain regions. Little emphasis has been put on the influence of cognitive and personality traits on neurofeedback efficacy and baseline activity. Here, we assessed the effect of individual pain coping on rt-fMRI neurofeedback during heat-induced pain. Twenty-eight healthy subjects completed the Coping Strategies Questionnaire (CSQ) prior to scanning. The first part of the fMRI experiment identified target regions using painful heat stimulation. Then, subjects were asked to down-regulate the pain target brain region during four neurofeedback runs with painful heat stimulation. Functional MRI analysis included correlation analysis between fMRI activation and pain ratings as well as CSQ ratings. At the behavioral level, the active pain coping (first principal component of CSQ) was correlated with pain ratings during neurofeedback. Concerning neuroimaging, pain sensitive regions were negatively correlated with pain coping. During neurofeedback, the pain coping was positively correlated with activation in the anterior cingulate cortex, prefrontal cortex, hippocampus and visual cortex. Thermode temperature was negatively correlated with anterior insula and dorsolateral prefrontal cortex activation. In conclusion, self-reported pain coping mechanisms and pain sensitivity are a source of variance during rt-fMRI neurofeedback possibly explaining variations in regulation success. In particular, active coping seems to be associated with successful pain regulation.

  16. Field Demonstration of Real-Time Wind Turbine Foundation Strain Monitoring.

    PubMed

    Rubert, Tim; Perry, Marcus; Fusiek, Grzegorz; McAlorum, Jack; Niewczas, Pawel; Brotherston, Amanda; McCallum, David

    2017-12-31

    Onshore wind turbine foundations are generally over-engineered as their internal stress states are challenging to directly monitor during operation. While there are industry drivers to shift towards more economical foundation designs, making this transition safely will require new monitoring techniques, so that the uncertainties around structural health can be reduced. This paper presents the initial results of a real-time strain monitoring campaign for an operating wind turbine foundation. Selected reinforcement bars were instrumented with metal packaged optical fibre strain sensors prior to concrete casting. In this paper, we outline the sensors' design, characterisation and installation, and present 67 days of operational data. During this time, measured foundation strains did not exceed 95 μ ϵ , and showed a strong correlation with both measured tower displacements and the results of a foundation finite element model. The work demonstrates that real-time foundation monitoring is not only achievable, but that it has the potential to help operators and policymakers quantify the conservatism of their existing design codes.

  17. Field Demonstration of Real-Time Wind Turbine Foundation Strain Monitoring

    PubMed Central

    Rubert, Tim; Niewczas, Pawel; Brotherston, Amanda; McCallum, David

    2017-01-01

    Onshore wind turbine foundations are generally over-engineered as their internal stress states are challenging to directly monitor during operation. While there are industry drivers to shift towards more economical foundation designs, making this transition safely will require new monitoring techniques, so that the uncertainties around structural health can be reduced. This paper presents the initial results of a real-time strain monitoring campaign for an operating wind turbine foundation. Selected reinforcement bars were instrumented with metal packaged optical fibre strain sensors prior to concrete casting. In this paper, we outline the sensors’ design, characterisation and installation, and present 67 days of operational data. During this time, measured foundation strains did not exceed 95 μϵ, and showed a strong correlation with both measured tower displacements and the results of a foundation finite element model. The work demonstrates that real-time foundation monitoring is not only achievable, but that it has the potential to help operators and policymakers quantify the conservatism of their existing design codes. PMID:29301232

  18. Monitoring tumor motion by real time 2D/3D registration during radiotherapy.

    PubMed

    Gendrin, Christelle; Furtado, Hugo; Weber, Christoph; Bloch, Christoph; Figl, Michael; Pawiro, Supriyanto Ardjo; Bergmann, Helmar; Stock, Markus; Fichtinger, Gabor; Georg, Dietmar; Birkfellner, Wolfgang

    2012-02-01

    In this paper, we investigate the possibility to use X-ray based real time 2D/3D registration for non-invasive tumor motion monitoring during radiotherapy. The 2D/3D registration scheme is implemented using general purpose computation on graphics hardware (GPGPU) programming techniques and several algorithmic refinements in the registration process. Validation is conducted off-line using a phantom and five clinical patient data sets. The registration is performed on a region of interest (ROI) centered around the planned target volume (PTV). The phantom motion is measured with an rms error of 2.56 mm. For the patient data sets, a sinusoidal movement that clearly correlates to the breathing cycle is shown. Videos show a good match between X-ray and digitally reconstructed radiographs (DRR) displacement. Mean registration time is 0.5 s. We have demonstrated that real-time organ motion monitoring using image based markerless registration is feasible. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  19. Real-time simulation of the nonlinear visco-elastic deformations of soft tissues.

    PubMed

    Basafa, Ehsan; Farahmand, Farzam

    2011-05-01

    Mass-spring-damper (MSD) models are often used for real-time surgery simulation due to their fast response and fairly realistic deformation replication. An improved real time simulation model of soft tissue deformation due to a laparoscopic surgical indenter was developed and tested. The mechanical realization of conventional MSD models was improved using nonlinear springs and nodal dampers, while their high computational efficiency was maintained using an adapted implicit integration algorithm. New practical algorithms for model parameter tuning, collision detection, and simulation were incorporated. The model was able to replicate complex biological soft tissue mechanical properties under large deformations, i.e., the nonlinear and viscoelastic behaviors. The simulated response of the model after tuning of its parameters to the experimental data of a deer liver sample, closely tracked the reference data with high correlation and maximum relative differences of less than 5 and 10%, for the tuning and testing data sets respectively. Finally, implementation of the proposed model and algorithms in a graphical environment resulted in a real-time simulation with update rates of 150 Hz for interactive deformation and haptic manipulation, and 30 Hz for visual rendering. The proposed real time simulation model of soft tissue deformation due to a laparoscopic surgical indenter was efficient, realistic, and accurate in ex vivo testing. This model is a suitable candidate for testing in vivo during laparoscopic surgery.

  20. Comparing Gravimetric and Real-Time Sampling of PM2.5 Concentrations Inside Truck Cabins

    PubMed Central

    Zhu, Ying; Smith, Thomas J.; Davis, Mary E.; Levy, Jonathan I.; Herrick, Robert; Jiang, Hongyu

    2012-01-01

    As part of a study on truck drivers’ exposure and health risk, pickup and delivery (P&D) truck drivers’ on-road exposure patterns to PM2.5 were assessed in five weeklong sampling trips in metropolitan areas of five U.S. cities from April to August of 2006. Drivers were sampled with real-time (DustTrak) and gravimetric samplers to measure average in-cabin PM2.5 concentrations and to compare their correspondence in moving trucks. In addition, GPS measurements of truck locations, meteorological data, and driver behavioral data were collected throughout the day to determine which factors influence the relationship between real-time and gravimetric samplers. Results indicate that the association between average real-time and gravimetric PM2.5 measurements on moving trucks was fairly consistent (Spearman rank correlation of 0.63), with DustTrak measurements exceeding gravimetric measurements by approximately a factor of 2. This ratio differed significantly only between the industrial Midwest cities and the other three sampled cities scattered in the South and West. There was also limited evidence of an effect of truck age. Filter samples collected concurrently with DustTrak measurements can be used to calibrate average mass concentration responses for the DustTrak, allowing for real-time measurements to be integrated into longer-term studies of inter-city and intra-urban exposure patterns for truck drivers. PMID:21991940

  1. Comparing gravimetric and real-time sampling of PM(2.5) concentrations inside truck cabins.

    PubMed

    Zhu, Ying; Smith, Thomas J; Davis, Mary E; Levy, Jonathan I; Herrick, Robert; Jiang, Hongyu

    2011-11-01

    As part of a study on truck drivers' exposure and health risk, pickup and delivery (P&D) truck drivers' on-road exposure patterns to PM(2.5) were assessed in five, weeklong sampling trips in metropolitan areas of five U.S. cities from April to August of 2006. Drivers were sampled with real-time (DustTrak) and gravimetric samplers to measure average in-cabin PM(2.5) concentrations and to compare their correspondence in moving trucks. In addition, GPS measurements of truck locations, meteorological data, and driver behavioral data were collected throughout the day to determine which factors influence the relationship between real-time and gravimetric samplers. Results indicate that the association between average real-time and gravimetric PM(2.5) measurements on moving trucks was fairly consistent (Spearman rank correlation of 0.63), with DustTrak measurements exceeding gravimetric measurements by approximately a factor of 2. This ratio differed significantly only between the industrial Midwest cities and the other three sampled cities scattered in the South and West. There was also limited evidence of an effect of truck age. Filter samples collected concurrently with DustTrak measurements can be used to calibrate average mass concentration responses for the DustTrak, allowing for real-time measurements to be integrated into longer-term studies of inter-city and intra-urban exposure patterns for truck drivers.

  2. Canine spontaneous glioma: A translational model system for convection-enhanced delivery

    PubMed Central

    Dickinson, Peter J.; LeCouteur, Richard A.; Higgins, Robert J.; Bringas, John R.; Larson, Richard F.; Yamashita, Yoji; Krauze, Michal T.; Forsayeth, John; Noble, Charles O.; Drummond, Daryl C.; Kirpotin, Dmitri B.; Park, John W.; Berger, Mitchel S.; Bankiewicz, Krystof S.

    2010-01-01

    Canine spontaneous intracranial tumors bear striking similarities to their human tumor counterparts and have the potential to provide a large animal model system for more realistic validation of novel therapies typically developed in small rodent models. We used spontaneously occurring canine gliomas to investigate the use of convection-enhanced delivery (CED) of liposomal nanoparticles, containing topoisomerase inhibitor CPT-11. To facilitate visualization of intratumoral infusions by real-time magnetic resonance imaging (MRI), we included identically formulated liposomes loaded with Gadoteridol. Real-time MRI defined distribution of infusate within both tumor and normal brain tissues. The most important limiting factor for volume of distribution within tumor tissue was the leakage of infusate into ventricular or subarachnoid spaces. Decreased tumor volume, tumor necrosis, and modulation of tumor phenotype correlated with volume of distribution of infusate (Vd), infusion location, and leakage as determined by real-time MRI and histopathology. This study demonstrates the potential for canine spontaneous gliomas as a model system for the validation and development of novel therapeutic strategies for human brain tumors. Data obtained from infusions monitored in real time in a large, spontaneous tumor may provide information, allowing more accurate prediction and optimization of infusion parameters. Variability in Vd between tumors strongly suggests that real-time imaging should be an essential component of CED therapeutic trials to allow minimization of inappropriate infusions and accurate assessment of clinical outcomes. PMID:20488958

  3. Real-Time Detection of Tsunami Ionospheric Disturbances with a Stand-Alone GNSS Receiver: A Preliminary Feasibility Demonstration

    NASA Astrophysics Data System (ADS)

    Savastano, Giorgio; Komjathy, Attila; Verkhoglyadova, Olga; Mazzoni, Augusto; Crespi, Mattia; Wei, Yong; Mannucci, Anthony J.

    2017-04-01

    It is well known that tsunamis can produce gravity waves that propagate up to the ionosphere generating disturbed electron densities in the E and F regions. These ionospheric disturbances can be studied in detail using ionospheric total electron content (TEC) measurements collected by continuously operating ground-based receivers from the Global Navigation Satellite Systems (GNSS). Here, we present results using a new approach, named VARION (Variometric Approach for Real-Time Ionosphere Observation), and estimate slant TEC (sTEC) variations in a real-time scenario. Using the VARION algorithm we compute TEC variations at 56 GPS receivers in Hawaii as induced by the 2012 Haida Gwaii tsunami event. We observe TEC perturbations with amplitudes of up to 0.25 TEC units and traveling ionospheric perturbations (TIDs) moving away from the earthquake epicenter at an approximate speed of 316 m/s. We perform a wavelet analysis to analyze localized variations of power in the TEC time series and we find perturbation periods consistent with a tsunami typical deep ocean period. Finally, we present comparisons with the real-time tsunami MOST (Method of Splitting Tsunami) model produced by the NOAA Center for Tsunami Research and we observe variations in TEC that correlate in time and space with the tsunami waves.

  4. Real-Time Detection of Tsunami Ionospheric Disturbances with a Stand-Alone GNSS Receiver: A Preliminary Feasibility Demonstration

    PubMed Central

    Savastano, Giorgio; Komjathy, Attila; Verkhoglyadova, Olga; Mazzoni, Augusto; Crespi, Mattia; Wei, Yong; Mannucci, Anthony J.

    2017-01-01

    It is well known that tsunamis can produce gravity waves that propagate up to the ionosphere generating disturbed electron densities in the E and F regions. These ionospheric disturbances can be studied in detail using ionospheric total electron content (TEC) measurements collected by continuously operating ground-based receivers from the Global Navigation Satellite Systems (GNSS). Here, we present results using a new approach, named VARION (Variometric Approach for Real-Time Ionosphere Observation), and estimate slant TEC (sTEC) variations in a real-time scenario. Using the VARION algorithm we compute TEC variations at 56 GPS receivers in Hawaii as induced by the 2012 Haida Gwaii tsunami event. We observe TEC perturbations with amplitudes of up to 0.25 TEC units and traveling ionospheric perturbations (TIDs) moving away from the earthquake epicenter at an approximate speed of 316 m/s. We perform a wavelet analysis to analyze localized variations of power in the TEC time series and we find perturbation periods consistent with a tsunami typical deep ocean period. Finally, we present comparisons with the real-time tsunami MOST (Method of Splitting Tsunami) model produced by the NOAA Center for Tsunami Research and we observe variations in TEC that correlate in time and space with the tsunami waves. PMID:28429754

  5. Real-Time Detection of Tsunami Ionospheric Disturbances with a Stand-Alone GNSS Receiver: A Preliminary Feasibility Demonstration.

    PubMed

    Savastano, Giorgio; Komjathy, Attila; Verkhoglyadova, Olga; Mazzoni, Augusto; Crespi, Mattia; Wei, Yong; Mannucci, Anthony J

    2017-04-21

    It is well known that tsunamis can produce gravity waves that propagate up to the ionosphere generating disturbed electron densities in the E and F regions. These ionospheric disturbances can be studied in detail using ionospheric total electron content (TEC) measurements collected by continuously operating ground-based receivers from the Global Navigation Satellite Systems (GNSS). Here, we present results using a new approach, named VARION (Variometric Approach for Real-Time Ionosphere Observation), and estimate slant TEC (sTEC) variations in a real-time scenario. Using the VARION algorithm we compute TEC variations at 56 GPS receivers in Hawaii as induced by the 2012 Haida Gwaii tsunami event. We observe TEC perturbations with amplitudes of up to 0.25 TEC units and traveling ionospheric perturbations (TIDs) moving away from the earthquake epicenter at an approximate speed of 316 m/s. We perform a wavelet analysis to analyze localized variations of power in the TEC time series and we find perturbation periods consistent with a tsunami typical deep ocean period. Finally, we present comparisons with the real-time tsunami MOST (Method of Splitting Tsunami) model produced by the NOAA Center for Tsunami Research and we observe variations in TEC that correlate in time and space with the tsunami waves.

  6. Ultrasonic Determination Of Recrystallization

    NASA Technical Reports Server (NTRS)

    Generazio, Edward R.

    1988-01-01

    State of recrystallization identified. Measurement of ultrasonic attenuation shows promise as means of detecting recrystallization in metal. Technique applicable to real-time acoustic monitoring of thermomechanical treatments. Starting with work-hardened material, one ultrasonically determines effect of annealing, using correlation between ultrasonic attenuation and temperature.

  7. The value of molecular expression of KIT and KIT ligand analysed using real-time polymerase chain reaction and immunohistochemistry as a prognostic indicator for canine cutaneous mast cell tumours.

    PubMed

    Costa Casagrande, T A; de Oliveira Barros, L M; Fukumasu, H; Cogliati, B; Chaible, L M; Dagli, M L Z; Matera, J M

    2015-03-01

    This study investigated the correlation between KIT gene expression determined by immunohistochemistry and real-time polymerase chain reaction (RT-PCR) and the rate of tumour recurrence and tumour-related deaths in dogs affected with mast cell tumour (MCT). Kaplan-Meier curves were constructed to compare tumour recurrence and tumour-related death between patients. The log-rank test was used to check for significant differences between curves. KIT-I, KIT-II and KIT-III staining patterns were observed in 9 (11.11%), 50 (61.73%) and 22 (27.16%) tumours, respectively. Tumour recurrence rates and tumour-related deaths were not associated with KIT staining patterns (P = 0278, P > 0.05), KIT (P = 0.289, P > 0.05) or KIT ligand (P = 0.106, P > 0.05) gene expression. Despite the lack of association between KIT staining pattern and patient survival time, the results suggest a correlation between aberrant KIT localization and increased proliferative activity of MCTs. RT-PCR seems to be a sensible method for quantitative detection of KIT gene expression in canine MCT, although expressions levels are not correlated with prognosis. © 2013 Blackwell Publishing Ltd.

  8. Lack of correlation between reaction speed and analytical sensitivity in isothermal amplification reveals the value of digital methods for optimization: validation using digital real-time RT-LAMP

    PubMed Central

    Khorosheva, Eugenia M.; Karymov, Mikhail A.; Selck, David A.; Ismagilov, Rustem F.

    2016-01-01

    In this paper, we asked if it is possible to identify the best primers and reaction conditions based on improvements in reaction speed when optimizing isothermal reactions. We used digital single-molecule, real-time analyses of both speed and efficiency of isothermal amplification reactions, which revealed that improvements in the speed of isothermal amplification reactions did not always correlate with improvements in digital efficiency (the fraction of molecules that amplify) or with analytical sensitivity. However, we observed that the speeds of amplification for single-molecule (in a digital device) and multi-molecule (e.g. in a PCR well plate) formats always correlated for the same conditions. Also, digital efficiency correlated with the analytical sensitivity of the same reaction performed in a multi-molecule format. Our finding was supported experimentally with examples of primer design, the use or exclusion of loop primers in different combinations, and the use of different enzyme mixtures in one-step reverse-transcription loop-mediated amplification (RT-LAMP). Our results show that measuring the digital efficiency of amplification of single-template molecules allows quick, reliable comparisons of the analytical sensitivity of reactions under any two tested conditions, independent of the speeds of the isothermal amplification reactions. PMID:26358811

  9. Vehicle-borne IED detection using the ULTOR correlation processor

    NASA Astrophysics Data System (ADS)

    Burcham, Joel D.; Vachon, Joyce E.

    2006-05-01

    Advanced Optical Systems, Inc. developed the ULTOR(r) system, a real-time correlation processor that looks for improvised explosive devices (IED) by examining imagery of vehicles. The system determines the level of threat an approaching vehicle may represent. The system works on incoming video collected at different wavelengths, including visible, infrared, and synthetic aperture radar. Sensors that attach to ULTOR can be located wherever necessary to improve the safety around a checkpoint. When a suspect vehicle is detected, ULTOR can track the vehicle, alert personnel, check for previous instances of the vehicle, and update other networked systems with the threat information. The ULTOR processing engine focuses on the spatial frequency information available in the image. It correlates the imagery with templates that specify the criteria defining a suspect vehicle. It can perform full field correlations at a rate of 180 Hz or better. Additionally, the spatial frequency information is applied to a trained neural network to identify suspect vehicles. We have performed various laboratory and field experiments to verify the performance of the ULTOR system in a counter IED environment. The experiments cover tracking specific targets in video clips to demonstrating real-time ULTOR system performance. The selected targets in the experiments include various automobiles in both visible and infrared video.

  10. Phase transitions in the first-passage time of scale-invariant correlated processes

    PubMed Central

    Carretero-Campos, Concepción; Bernaola-Galván, Pedro; Ch. Ivanov, Plamen

    2012-01-01

    A key quantity describing the dynamics of complex systems is the first-passage time (FPT). The statistical properties of FPT depend on the specifics of the underlying system dynamics. We present a unified approach to account for the diversity of statistical behaviors of FPT observed in real-world systems. We find three distinct regimes, separated by two transition points, with fundamentally different behavior for FPT as a function of increasing strength of the correlations in the system dynamics: stretched exponential, power-law, and saturation regimes. In the saturation regime, the average length of FPT diverges proportionally to the system size, with important implications for understanding electronic delocalization in one-dimensional correlated-disordered systems. PMID:22400544

  11. A 32-channel photon counting module with embedded auto/cross-correlators for real-time parallel fluorescence correlation spectroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gong, S.; Labanca, I.; Rech, I.

    2014-10-15

    Fluorescence correlation spectroscopy (FCS) is a well-established technique to study binding interactions or the diffusion of fluorescently labeled biomolecules in vitro and in vivo. Fast FCS experiments require parallel data acquisition and analysis which can be achieved by exploiting a multi-channel Single Photon Avalanche Diode (SPAD) array and a corresponding multi-input correlator. This paper reports a 32-channel FPGA based correlator able to perform 32 auto/cross-correlations simultaneously over a lag-time ranging from 10 ns up to 150 ms. The correlator is included in a 32 × 1 SPAD array module, providing a compact and flexible instrument for high throughput FCS experiments.more » However, some inherent features of SPAD arrays, namely afterpulsing and optical crosstalk effects, may introduce distortions in the measurement of auto- and cross-correlation functions. We investigated these limitations to assess their impact on the module and evaluate possible workarounds.« less

  12. Black carbon emissions in gasoline vehicle exhaust: a measurement and instrument comparison.

    PubMed

    Kamboures, Michael A; Hu, Shishan; Yu, Yong; Sandoval, Julia; Rieger, Paul; Huang, Shiou-Mei; Zhang, Sherry; Dzhema, Inna; Huo, Darey; Ayala, Alberto; Chang, M C Oliver

    2013-08-01

    A pilot study was conducted to evaluate the performance and agreement of several commercially available black carbon (BC) measurement instruments, when applied to the quantification of BC in light-duty vehicle (LDV) exhaust. Samples from six vehicles, three fuels, and three driving cycles were used. The pilot study included determinations of the method detection limit (MDL) and repeatability. With respect to the MDL, the real-time instruments outperformed the time-integrated instruments, with MDL = 0.12 mg/mi for the AE51 Aethalometer, and 0.15 mg/mi for the Micro Soot Sensor (MSS), versus 0.38 mg/mi for the IMPROVE_A thermal/ optical method, and 0.35 mg/mi for the OT21_T Optical Transmissometer. The real-time instruments had repeatability values ranging from 30% to 35%, which are somewhat better than those of the time-integrated instruments (40-41%). These results suggest that, despite being less resource intensive, real-time methods can be equivalent or superior to time-integrated methods in terms of sensitivity and repeatability. BC mass data, from the photoacoustic and light attenuation instruments, were compared against same-test EC data, determined using the IMPROVE_A method. The MSS BC data was well correlated with EC, with R2 = 0.85 for the composite results and R2 = 0.86 for the phase-by-phase (PBP) results. The correlation of BC, by the AE51, AE22, and OT21_T with EC was moderate to weak. The weaker correlation was driven by the inclusion of US06 test data in the linear regression analysis. We hypothesize that test-cycle-dependent BC:EC ratios are due to the different physicochemical properties of particulate matter (PM) in US06 and Federal Test Procedure (FTP) tests. Correlation amongst the real-time MSS, PASS-1, AE51, and AE22 instruments was excellent (R2 = 0.83-0.95), below 1 mg/mi levels. In the process of investigating these BC instruments, we learned that BC emissions at sub-1 mg/mi levels can be measured and are achievable by current-generation gasoline engines. Most comparison studies of black carbon (BC) measurement methods were carried out in the ambient air. This study assesses the agreement among various BC measurement instrument in emissions from light-duty gasoline vehicles (LDGVs) on standard test cycles, and evaluates applicability of these methods under various fuel types, driving cycles, and engine combustion technologies. This research helps to fill in the knowledge gap of BC method standardization as stated in the U.S. Environmental Protection Agency (EPA) 2011 Report to Congress on Black Carbon, and these results demonstrate the feasibility of quantification of BC at the 1 mg/mi PM standard in California Low Emission Vehicle III regulations.

  13. Robust technology and system for management of sucker rod pumping units in oil wells

    NASA Astrophysics Data System (ADS)

    Aliev, T. A.; Rzayev, A. H.; Guluyev, G. A.; Alizada, T. A.; Rzayeva, N. E.

    2018-01-01

    We propose a technology for calculating the robust, normalized correlation functions of the signal from the force sensor on the rod string attached to the hanger of the sucker rod pumping unit. The robust normalized correlation functions are used to form sets of informative attribute combinations, each of which corresponds to a technical condition of the sucker rod pumping unit. We demonstrate how these sets can be used to solve identification and management problems in the oil production process in real time using inexpensive controllers. The results obtained from using the system on real objects are also presented in this paper. It was determined that the energy saved and prolonged overhaul period substantially increased the cost-effectiveness.

  14. Dynamic Monitoring of Cleanroom Fallout Using an Air Particle Counter

    NASA Technical Reports Server (NTRS)

    Perry, Radford

    2011-01-01

    The particle fallout limitations and periodic allocations for the James Webb Space Telescope are very stringent. Standard prediction methods are complicated by non-linearity and monitoring methods that are insufficiently responsive. A method for dynamically predicting the particle fallout in a cleanroom using air particle counter data was determined by numerical correlation. This method provides a simple linear correlation to both time and air quality, which can be monitored in real time. The summation of effects provides the program better understanding of the cleanliness and assists in the planning of future activities. Definition of fallout rates within a cleanroom during assembly and integration of contamination-sensitive hardware, such as the James Webb Space Telescope, is essential for budgeting purposes. Balancing the activity levels for assembly and test with the particle accumulation rate is paramount. The current approach to predicting particle fallout in a cleanroom assumes a constant air quality based on the rated class of a cleanroom, with adjustments for projected work or exposure times. Actual cleanroom class can also depend on the number of personnel present and the type of activities. A linear correlation of air quality and normalized particle fallout was determined numerically. An air particle counter (standard cleanroom equipment) can be used to monitor the air quality on a real-time basis and determine the "class" of the cleanroom (per FED-STD-209 or ISO-14644). The correlation function provides an area coverage coefficient per class-hour of exposure. The prediction of particle accumulations provides scheduling inputs for activity levels and cleanroom class requirements.

  15. Real-time optical image processing techniques

    NASA Technical Reports Server (NTRS)

    Liu, Hua-Kuang

    1988-01-01

    Nonlinear real-time optical processing on spatial pulse frequency modulation has been pursued through the analysis, design, and fabrication of pulse frequency modulated halftone screens and the modification of micro-channel spatial light modulators (MSLMs). Micro-channel spatial light modulators are modified via the Fabry-Perot method to achieve the high gamma operation required for non-linear operation. Real-time nonlinear processing was performed using the halftone screen and MSLM. The experiments showed the effectiveness of the thresholding and also showed the needs of higher SBP for image processing. The Hughes LCLV has been characterized and found to yield high gamma (about 1.7) when operated in low frequency and low bias mode. Cascading of two LCLVs should also provide enough gamma for nonlinear processing. In this case, the SBP of the LCLV is sufficient but the uniformity of the LCLV needs improvement. These include image correlation, computer generation of holograms, pseudo-color image encoding for image enhancement, and associative-retrieval in neural processing. The discovery of the only known optical method for dynamic range compression of an input image in real-time by using GaAs photorefractive crystals is reported. Finally, a new architecture for non-linear multiple sensory, neural processing has been suggested.

  16. Towards real time 2D to 3D registration for ultrasound-guided endoscopic and laparoscopic procedures.

    PubMed

    San José Estépar, Raúl; Westin, Carl-Fredrik; Vosburgh, Kirby G

    2009-11-01

    A method to register endoscopic and laparoscopic ultrasound (US) images in real time with pre-operative computed tomography (CT) data sets has been developed with the goal of improving diagnosis, biopsy guidance, and surgical interventions in the abdomen. The technique, which has the potential to operate in real time, is based on a new phase correlation technique: LEPART, which specifies the location of a plane in the CT data which best corresponds to the US image. Validation of the method was carried out using an US phantom with cyst regions and with retrospective analysis of data sets from animal model experiments. The phantom validation study shows that local translation displacements can be recovered for each US frame with a root mean squared error of 1.56 +/- 0.78 mm in less than 5 sec, using non-optimized algorithm implementations. A new method for multimodality (preoperative CT and intraoperative US endoscopic images) registration to guide endoscopic interventions was developed and found to be efficient using clinically realistic datasets. The algorithm is inherently capable of being implemented in a parallel computing system so that full real time operation appears likely.

  17. Dual-probe real-time PCR assay for detection of variola or other orthopoxviruses with dried reagents.

    PubMed

    Aitichou, Mohamed; Saleh, Sharron; Kyusung, Park; Huggins, John; O'Guinn, Monica; Jahrling, Peter; Ibrahim, Sofi

    2008-11-01

    A real-time, multiplexed polymerase chain reaction (PCR) assay based on dried PCR reagents was developed. Only variola virus could be specifically detected by a FAM (6-carboxyfluorescein)-labeled probe while camelpox, cowpox, monkeypox and vaccinia viruses could be detected by a TET (6-carboxytetramethylrhodamine)-labeled probe in a single PCR reaction. Approximately 25 copies of cloned variola virus DNA and 50 copies of genomic orthopoxviruses DNA could be detected with high reproducibility. The assay exhibited a dynamic range of seven orders of magnitude with a correlation coefficient value greater than 0.97. The sensitivity and specificity of the assay, as determined from 100 samples that contained nucleic acids from a multitude of bacterial and viral species were 96% and 98%, respectively. The limit of detection, sensitivity and specificity of the assay were comparable to standard real-time PCR assays with wet reagents. Employing a multiplexed format in this assay allows simultaneous discrimination of the variola virus from other closely related orthopoxviruses. Furthermore, the implementation of dried reagents in real-time PCR assays is an important step towards simplifying such assays and allowing their use in areas where cold storage is not easily accessible.

  18. Integrated inertial sensors and mobile computing for real-time cycling performance guidance via pedaling profile classification.

    PubMed

    Xu, James Y; Nan, Xiaomeng; Ebken, Victor; Wang, Yan; Pottie, Greg J; Kaiser, William J

    2015-03-01

    Today, the bicycle is utilized as a daily commute tool, a physical rehabilitation asset, and sporting equipment, prompting studies into the biomechanics of cycling. Of the number of important parameters that affect cycling efficiency, the foot angle profile is one of the most important as it correlates directly with the effective force applied to the bike. However, there has been no compact and portable solution for measuring the foot angle and for providing the cyclist with real-time feedback due to a number of difficulties of the current tracking and sensing technologies and the myriad types of bikes available. This paper presents a novel sensing and mobile computing system for classifying the foot angle profiles during cycling and for providing real-time guidance to the user to achieve the correct profile. Continuous foot angle tracking is firstly converted into a discrete problem requiring only recognition of acceleration profiles of the foot using a single shoe mounted tri-axial accelerometer during each pedaling cycle. A classification method is then applied to identify the pedaling profile. Finally, a mobile solution is presented to provide real-time signal processing and guidance.

  19. Real-time geometry-aware augmented reality in minimally invasive surgery.

    PubMed

    Chen, Long; Tang, Wen; John, Nigel W

    2017-10-01

    The potential of augmented reality (AR) technology to assist minimally invasive surgery (MIS) lies in its computational performance and accuracy in dealing with challenging MIS scenes. Even with the latest hardware and software technologies, achieving both real-time and accurate augmented information overlay in MIS is still a formidable task. In this Letter, the authors present a novel real-time AR framework for MIS that achieves interactive geometric aware AR in endoscopic surgery with stereo views. The authors' framework tracks the movement of the endoscopic camera and simultaneously reconstructs a dense geometric mesh of the MIS scene. The movement of the camera is predicted by minimising the re-projection error to achieve a fast tracking performance, while the three-dimensional mesh is incrementally built by a dense zero mean normalised cross-correlation stereo-matching method to improve the accuracy of the surface reconstruction. The proposed system does not require any prior template or pre-operative scan and can infer the geometric information intra-operatively in real time. With the geometric information available, the proposed AR framework is able to interactively add annotations, localisation of tumours and vessels, and measurement labelling with greater precision and accuracy compared with the state-of-the-art approaches.

  20. Real-time intravascular photoacoustic-ultrasound imaging of lipid-laden plaque at speed of video-rate level

    NASA Astrophysics Data System (ADS)

    Hui, Jie; Cao, Yingchun; Zhang, Yi; Kole, Ayeeshik; Wang, Pu; Yu, Guangli; Eakins, Gregory; Sturek, Michael; Chen, Weibiao; Cheng, Ji-Xin

    2017-03-01

    Intravascular photoacoustic-ultrasound (IVPA-US) imaging is an emerging hybrid modality for the detection of lipidladen plaques by providing simultaneous morphological and lipid-specific chemical information of an artery wall. The clinical utility of IVPA-US technology requires real-time imaging and display at speed of video-rate level. Here, we demonstrate a compact and portable IVPA-US system capable of imaging at up to 25 frames per second in real-time display mode. This unprecedented imaging speed was achieved by concurrent innovations in excitation laser source, rotary joint assembly, 1 mm IVPA-US catheter, differentiated A-line strategy, and real-time image processing and display algorithms. By imaging pulsatile motion at different imaging speeds, 16 frames per second was deemed to be adequate to suppress motion artifacts from cardiac pulsation for in vivo applications. Our lateral resolution results further verified the number of A-lines used for a cross-sectional IVPA image reconstruction. The translational capability of this system for the detection of lipid-laden plaques was validated by ex vivo imaging of an atherosclerotic human coronary artery at 16 frames per second, which showed strong correlation to gold-standard histopathology.

  1. Evaluation of fatty liver fibrosis in rabbits using real-time shear wave elastography

    PubMed Central

    LU, YONGPING; WEI, JIA; TANG, YUEYUE; YUAN, YUAN; HUANG, YANLING; ZHANG, YONG; LI, YUNYAN

    2014-01-01

    The aim of the present study was to detect the elastic modulus (stiffness) of the livers of rabbits with non-alcoholic and alcoholic fatty liver disease using real-time shear wave elastography (SWE), and to investigate the fibrosis development process in the formation of fatty liver. The stiffness of the fatty livers in rabbit models prepared via feeding with alcohol or a high-fat diet were measured using a real-time SWE ultrasound system and a 4–15-MHz linear array probe, and the liver stiffness was compared with the pathological staging of the disease. The stiffness of the liver was positively correlated with the degree of pathological change in fatty liver disease (P<0.01). The stiffness of the liver in the alcoholic fatty liver group was higher compared with that in the non-alcoholic fatty liver and control groups, and the stiffness in the non-alcoholic fatty liver group was higher than that in the control group (P<0.01). Real-time SWE objectively identified the trend in the changing stiffness of the liver and noninvasively detected the development of fibrosis in the progression of non-alcoholic and alcoholic fatty liver disease. PMID:25009583

  2. A nanometallic nickel-coated, glass-fibre-based structural health monitoring system for polymer composites

    NASA Astrophysics Data System (ADS)

    Balaji, R.; Sasikumar, M.

    2017-09-01

    Glass-fibre-reinforced polymer matrix composites are widely used in various industries because of their unique high strength to weight ratio. Unlike metals, strain-induced and damage states of composites are complicated to predict under real-time loading due to their anisotropic nature. With that focus, a piezoresistive nanomaterial-based structural health monitoring system for laminated polymer composites is proposed to measure the strain induced in the composite under real-time loading. Nanometallic nickel-coated glass fibres are embedded into the polymer composites to monitor the strain and damage induced in them. The nanometallic nickel is coated over the glass fibre by a dip coating technique using epoxy as the binding agent. A microcontroller-based electrical resistance measurement system is used to measure the piezoresistive variation in the coated glass fibre under real-time loading. Using the piezoresistance variation of the embedded nanometallic nickel-coated glass fibre, the real-time strain and damage induced in the composite can be correlated. The piezoresistive response of the coated glass fibre is descibed in two phases, the deformation phase and the failure phase, which clearly show the various states of strain and damage induced in the composites.

  3. [Experimental studies of using real-time fluorescence quantitative PCR and RT-PCR to detect E6 and E7 genes of human papillomavirus type 16 in cervical carcinoma cell lines].

    PubMed

    Chen, Yue-yue; Peng, Zhi-lan; Liu, Shan-ling; He, Bing; Hu, Min

    2007-06-01

    To establish a method of using real-time fluorescence quantitative PCR and RT-PCR to detect the E6 and E7 genes of human papillomavirus type 16 (HPV-16). Plasmids containing HPV-16 E6 or E7 were used to generate absolute standard curves. Three cervical carcinoma cell lines CaSki, SiHa and HeLa were tested by real-time fluorescence quantitative PCR and RT-PCR analyses for the expressions of HPV-16 E6 and E7. The correlation coefficients of standard curves were larger than 0. 99, and the PCR efficiency was more than 90%. The relative levels of HPV-16 E6 and E7 DNA and RNA were CaSki>SiHa>HeLa cell. HPV-16 E6 and E7 quantum by real-time fluorescence quantitative PCR and RT-PCR analyses may serve as a reliable and sensitive tool. This study provides the possibility of further researches on the relationship between HPV-16 E6 or E7 copy number and cervical carcinoma.

  4. Rapid and sensitive detection of canine distemper virus by real-time reverse transcription recombinase polymerase amplification.

    PubMed

    Wang, Jianchang; Wang, Jinfeng; Li, Ruiwen; Liu, Libing; Yuan, Wanzhe

    2017-08-15

    Canine distemper, caused by Canine distemper virus (CDV), is a highly contagious and fatal systemic disease in free-living and captive carnivores worldwide. Recombinase polymerase amplification (RPA), as an isothermal gene amplification technique, has been explored for the molecular detection of diverse pathogens. A real-time reverse transcription RPA (RT-RPA) assay for the detection of canine distemper virus (CDV) using primers and exo probe targeting the CDV nucleocapsid protein gene was developed. A series of other viruses were tested by the RT-RPA.Thirty-two field samples were further tested by RT-RPA, and the resuts were compared with those obtained by the real-time RT-PCR. The RT-RPA assay was performed successfully at 40 °C, and the results were obtained within 3 min-12 min. The assay could detect CDV, but did not show cross-detection of canine parvovirus-2 (CPV-2), canine coronavirus (CCoV), canine parainfluenza virus (CPIV), pseudorabies virus (PRV) or Newcastle disease virus (NDV), demonstrating high specificity. The analytical sensitivity of RT-RPA was 31.8 copies in vitro transcribed CDV RNA, which is 10 times lower than the real-time RT-PCR. The assay performance was validated by testing 32 field samples and compared to real-time RT-PCR. The results indicated an excellent correlation between RT-RPA and a reference real-time RT-PCR method. Both assays provided the same results, and R 2 value of the positive results was 0.947. The results demonstrated that the RT-RPA assay offers an alternative tool for simple, rapid, and reliable detection of CDV both in the laboratory and point-of-care facility, especially in the resource-limited settings.

  5. Evaluation of the Abbott RealTime HCV assay for quantitative detection of hepatitis C virus RNA.

    PubMed

    Michelin, Birgit D A; Muller, Zsofia; Stelzl, Evelyn; Marth, Egon; Kessler, Harald H

    2007-02-01

    The Abbott RealTime HCV assay for quantitative detection of HCV RNA has recently been introduced. In this study, the performance of the Abbott RealTime HCV assay was evaluated and compared to the COBAS AmpliPrep/COBAS TaqMan HCV test. Accuracy, linearity, interassay and intra-assay variations were determined, and a total of 243 routine clinical samples were investigated. When accuracy of the new assay was tested, the majority of results were found to be within +/-0.5 log(10) unit of the results obtained by reference laboratories. Determination of linearity resulted in a quasilinear curve up to 1.0 x 10(6)IU/ml. The interassay variation ranged from 15% to 32%, and the intra-assay variation ranged from 5% to 8%. When clinical samples were tested by the Abbott RealTime HCV assay and the results were compared with those obtained by the COBAS AmpliPrep/COBAS TaqMan HCV test, the results for 93% of all samples with positive results by both tests were found to be within +/-1.0 log(10) unit. The viral loads for all patients measured by the Abbott and Roche assays showed a high correlation (R(2)=0.93); quantitative results obtained by the Abbott assay were found to be lower than those obtained by the Roche assay. The Abbott RealTime HCV assay proved to be suitable for use in the routine diagnostic laboratory. The time to results was similar for both of the assays.

  6. Lead-lag cross-sectional structure and detection of correlated anticorrelated regime shifts: Application to the volatilities of inflation and economic growth rates

    NASA Astrophysics Data System (ADS)

    Zhou, Wei-Xing; Sornette, Didier

    2007-07-01

    We have recently introduced the “thermal optimal path” (TOP) method to investigate the real-time lead-lag structure between two time series. The TOP method consists in searching for a robust noise-averaged optimal path of the distance matrix along which the two time series have the greatest similarity. Here, we generalize the TOP method by introducing a more general definition of distance which takes into account possible regime shifts between positive and negative correlations. This generalization to track possible changes of correlation signs is able to identify possible transitions from one convention (or consensus) to another. Numerical simulations on synthetic time series verify that the new TOP method performs as expected even in the presence of substantial noise. We then apply it to investigate changes of convention in the dependence structure between the historical volatilities of the USA inflation rate and economic growth rate. Several measures show that the new TOP method significantly outperforms standard cross-correlation methods.

  7. Real-time in situ nanoclustering during initial stages of artificial aging of Al-Cu alloys

    NASA Astrophysics Data System (ADS)

    Zatsepin, Nadia A.; Dilanian, Ruben A.; Nikulin, Andrei Y.; Gao, Xiang; Muddle, Barry C.; Matveev, Victor N.; Sakata, Osami

    2010-01-01

    We report an experimental demonstration of real-time in situ x-ray diffraction investigations of clustering and dynamic strain in early stages of nanoparticle growth in Al-Cu alloys. Simulations involving a simplified model of local strain are well correlated with the x-ray diffraction data, suggesting a redistribution of point defects and the formation of nanoscale clusters in the bulk material. A modal, representative nanoparticle size is determined subsequent to the final stage of artificial aging. Such investigations are imperative for the understanding, and ultimately the control, of nanoparticle nucleation and growth in this technologically important alloy.

  8. Parallel, Real-Time and Pipeline Data Reduction for the ROVER Sub-mm Heterodyne Polarimeter on the JCMT with ACSIS and ORAC-DR

    NASA Astrophysics Data System (ADS)

    Leech, J.; Dewitt, S.; Jenness, T.; Greaves, J.; Lightfoot, J. F.

    2005-12-01

    ROVER is a rotating waveplate polarimeter for use with (sub)mm heterodyne instruments, particularly the 16 element focal plane Heterodyne Array Receiver HARP tep{Smit2003} due for commissioning on the JCMT in 2004. The ROVER/HARP back-end will be a digital auto-correlation spectrometer, known as ACSIS, designed specifically for the demanding data volumes from the HARP array receiver. ACSIS is being developed by DRAO, Penticton and UKATC. This paper will describe the data reduction of ROVER polarimetry data both in real-time by ACSIS-DR, and through the ORAC-DR data reduction pipeline.

  9. Performance of point-of-care Xpert HIV-1 plasma viral load assay at a tertiary HIV care centre in Southern India.

    PubMed

    Swathirajan, Chinnambedu Ravichandran; Vignesh, Ramachandran; Boobalan, Jayaseelan; Solomon, Sunil Suhas; Saravanan, Shanmugam; Balakrishnan, Pachamuthu

    2017-10-01

    Sustainable suppression of HIV replication forms the basis of anti-retroviral therapy (ART) medication. Thus, reliable quantification of HIV viral load has become an essential factor to monitor the effectiveness of the ART. Longer turnaround-time (TAT), batch testing and technical skills are major drawbacks of standard real-time PCR assays. The performance of the point-of-care Xpert HIV-1 viral load assay was evaluated against the Abbott RealTime PCR m2000rt system. A total of 96 plasma specimens ranging from 2.5 log10 copies ml -1 to 4.99 log10 copies ml -1 and proficiency testing panel specimens were used. Precision and accuracy were checked using the Pearson correlation co-efficient test and Bland-Altman analysis. Compared to the Abbott RealTime PCR, the Xpert HIV-1 viral load assay showed a good correlation (Pearson r=0.81; P<0.0001) with a mean difference of 0.27 log10 copies ml -1 (95 % CI, -0.41 to 0.96 log10 copies ml -1 ; sd, 0.35 log10 copies ml -1 ). Reliable and ease of testing individual specimens could make the Xpert HIV-1 viral load assay an efficient alternative method for ART monitoring in clinical management of HIV disease in resource-limited settings. The rapid test results (less than 2 h) could help in making an immediate clinical decision, which further strengthens patient care.

  10. The SENSE-Isomorphism Theoretical Image Voxel Estimation (SENSE-ITIVE) Model for Reconstruction and Observing Statistical Properties of Reconstruction Operators

    PubMed Central

    Bruce, Iain P.; Karaman, M. Muge; Rowe, Daniel B.

    2012-01-01

    The acquisition of sub-sampled data from an array of receiver coils has become a common means of reducing data acquisition time in MRI. Of the various techniques used in parallel MRI, SENSitivity Encoding (SENSE) is one of the most common, making use of a complex-valued weighted least squares estimation to unfold the aliased images. It was recently shown in Bruce et al. [Magn. Reson. Imag. 29(2011):1267–1287] that when the SENSE model is represented in terms of a real-valued isomorphism, it assumes a skew-symmetric covariance between receiver coils, as well as an identity covariance structure between voxels. In this manuscript, we show that not only is the skew-symmetric coil covariance unlike that of real data, but the estimated covariance structure between voxels over a time series of experimental data is not an identity matrix. As such, a new model, entitled SENSE-ITIVE, is described with both revised coil and voxel covariance structures. Both the SENSE and SENSE-ITIVE models are represented in terms of real-valued isomorphisms, allowing for a statistical analysis of reconstructed voxel means, variances, and correlations resulting from the use of different coil and voxel covariance structures used in the reconstruction processes to be conducted. It is shown through both theoretical and experimental illustrations that the miss-specification of the coil and voxel covariance structures in the SENSE model results in a lower standard deviation in each voxel of the reconstructed images, and thus an artificial increase in SNR, compared to the standard deviation and SNR of the SENSE-ITIVE model where both the coil and voxel covariances are appropriately accounted for. It is also shown that there are differences in the correlations induced by the reconstruction operations of both models, and consequently there are differences in the correlations estimated throughout the course of reconstructed time series. These differences in correlations could result in meaningful differences in interpretation of results. PMID:22617147

  11. Mapping auroral activity with Twitter

    NASA Astrophysics Data System (ADS)

    Case, N. A.; MacDonald, E. A.; Heavner, M.; Tapia, A. H.; Lalone, N.

    2015-05-01

    Twitter is a popular, publicly accessible, social media service that has proven useful in mapping large-scale events in real time. In this study, for the first time, the use of Twitter as a measure of auroral activity is investigated. Peaks in the number of aurora-related tweets are found to frequently coincide with geomagnetic disturbances (detection rate of 91%). Additionally, the number of daily aurora-related tweets is found to strongly correlate with several auroral strength proxies (ravg≈0.7). An examination is made of the bias for location and time of day within Twitter data, and a first-order correction of these effects is presented. Overall, the results suggest that Twitter can provide both specific details about an individual aurora and accurate real-time indication of when, and even from where, an aurora is visible.

  12. Intraoperative diagnosis of nonpigmented nail tumours with ex vivo fluorescence confocal microscopy: 10 cases.

    PubMed

    Debarbieux, S; Gaspar, R; Depaepe, L; Dalle, S; Balme, B; Thomas, L

    2015-04-01

    Ex vivo fluorescence confocal microscopy (FCM) permits real-time imaging of freshly excised skin tissues. Its usefulness as a time-sparing alternative to frozen sections in Mohs surgery of basal cell carcinoma is well documented. The purpose of this study was to describe the ex vivo FCM features of a series of benign and malignant nonpigmented tumours of the nail unit, and to correlate them with conventional histopathology. Nail apparatus tumours from 10 patients were imaged during surgical exploration using ex vivo FCM after immersion in acridine orange. Confocal mosaics of the freshly performed biopsies were evaluated in real time and retrospectively compared with haematoxylin and eosin sections. Our series included two invasive epithelial tumours (Group 1), four in situ or minimally invasive squamous cell carcinomas (SCC) (Group 2), three benign epithelial tumours (Group 3) and one nodular melanoma (Group 4). The correlation was excellent for malignant epithelial tumours exhibiting marked cytological and architectural atypias (Bowen disease, invasive SCC and onycholemmal carcinoma). Onychomatricomas exhibited a very peculiar aspect with densely cellular papillae. The correlation was less favourable for minimally invasive well-differentiated SCCs with slight cytological atypias. The correlation was poor for our case of amelanotic invasive subungual melanoma. Ex vivo FCM could be a useful tool to shorten management of nonpigmented nail tumours: in the case of a malignant tumour, it could indeed lead to performing wide excision during the same surgical procedure and possibly assessing the surgical margins. © 2014 British Association of Dermatologists.

  13. On the equivalence of the RTI and SVM approaches to time correlated analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Croft, S.; Favalli, A.; Henzlova, D.

    2014-11-21

    Recently two papers on how to perform passive neutron auto-correlation analysis on time gated histograms formed from pulse train data, generically called time correlation analysis (TCA), have appeared in this journal [1,2]. For those of us working in international nuclear safeguards these treatments are of particular interest because passive neutron multiplicity counting is a widely deployed technique for the quantification of plutonium. The purpose of this letter is to show that the skewness-variance-mean (SVM) approach developed in [1] is equivalent in terms of assay capability to the random trigger interval (RTI) analysis laid out in [2]. Mathematically we could alsomore » use other numerical ways to extract the time correlated information from the histogram data including for example what we might call the mean, mean square, and mean cube approach. The important feature however, from the perspective of real world applications, is that the correlated information extracted is the same, and subsequently gets interpreted in the same way based on the same underlying physics model.« less

  14. Development of on package indicator sensor for real-time monitoring of meat quality

    PubMed Central

    Shukla, Vivek; Kandeepan, G.; Vishnuraj, M. R.

    2015-01-01

    Aim: The aim was to develop an indicator sensor for real-time monitoring of meat quality and to compare the response of indicator sensor with meat quality parameters at ambient temperature. Materials and Methods: Indicator sensor was prepared using bromophenol blue (1% w/v) as indicator solution and filter paper as indicator carrier. Indicator sensor was fabricated by coating indicator solution onto carrier by centrifugation. To observe the response of indicator sensor buffalo meat was packed in polystyrene foam trays covered with PVC film and indicator sensor was attached to the inner side of packaging film. The pattern of color change in indicator sensor was monitored and compared with meat quality parameters viz. total volatile basic nitrogen, D-glucose, standard plate count and tyrosine value to correlate ability of indicator sensor for its suitability to predict the meat quality and storage life. Results: The indicator sensor changed its color from yellow to blue starting from margins during the storage period of 24 h at ambient temperature and this correlated well with changes in meat quality parameters. Conclusions: The indicator sensor can be used for real-time monitoring of meat quality as the color of indicator sensor changed from yellow to blue starting from margins when meat deteriorates with advancement of the storage period. Thus by observing the color of indicator sensor quality of meat and shelf life can be predicted. PMID:27047103

  15. Detection of ground motions using high-rate GPS time-series

    NASA Astrophysics Data System (ADS)

    Psimoulis, Panos A.; Houlié, Nicolas; Habboub, Mohammed; Michel, Clotaire; Rothacher, Markus

    2018-05-01

    Monitoring surface deformation in real-time help at planning and protecting infrastructures and populations, manage sensitive production (i.e. SEVESO-type) and mitigate long-term consequences of modifications implemented. We present RT-SHAKE, an algorithm developed to detect ground motions associated with landslides, sub-surface collapses, subsidences, earthquakes or rock falls. RT-SHAKE detects first transient changes in individual GPS time series before investigating for spatial correlation(s) of observations made at neighbouring GPS sites and eventually issue a motion warning. In order to assess our algorithm on fast (seconds to minute), large (from 1 cm to meters) and spatially consistent surface motions, we use the 1 Hz GEONET GNSS network data of the Tohoku-Oki MW9.0 2011 as a test scenario. We show the delay of detection of seismic wave arrival by GPS records is of ˜10 seconds with respect to an identical analysis based on strong-motion data and this time delay depends on the level of the time-variable noise. Nevertheless, based on the analysis of the GPS network noise level and ground motion stochastic model, we show that RT-SHAKE can narrow the range of earthquake magnitude, by setting a lower threshold of detected earthquakes to MW6.5-7, if associated with a real-time automatic earthquake location system.

  16. Upgrades and Real Time Ntm Control Application of the Ece Radiometer on Asdex Upgrade

    NASA Astrophysics Data System (ADS)

    Hicks, N. K.; Suttrop, W.; Behler, K.; Giannone, L.; Manini, A.; Maraschek, M.; Raupp, G.; Reich, M.; Sips, A. C. C.; Stober, J.; Treutterer, W.; ASDEX Upgrade Team; Cirant, S.

    2009-04-01

    The 60-channel electron cyclotron emission (ECE) radiometer diagnostic on the ASDEX Upgrade tokamak is presently being upgraded to include a 1 MHz sampling rate data acquisition system. This expanded capability allows electron temperature measurements up to 500 kHz (anti-aliasing filter cut-off) with spatial resolution ~1 cm, and will thus provide measurement of plasma phenomena on the MHD timescale, such as neoclassical tearing modes (NTMs). The upgraded and existing systems may be run in parallel for comparison, and some of the first plasma measurements using the two systems together are presented. A particular planned application of the upgraded radiometer is integration into a real-time NTM stabilization loop using targeted deposition of electron cyclotron resonance heating (ECRH). For this loop, it is necessary to determine the locations of the NTM and ECRH deposition using ECE measurements. As the magnetic island of the NTM repeatedly rotates through the ECE line of sight, electron temperature fluctuations at the NTM frequency are observed. The magnetic perturbation caused by the NTM is independently measured using Mirnov coils, and a correlation profile between these magnetic measurements and the ECE data is constructed. The phase difference between ECE oscillations on opposite sides of the island manifests as a zero-crossing of the correlation profile, which determines the NTM location in ECE channel space. To determine the location of ECRH power deposition, the power from a given gyrotron may be modulated at a particular frequency. Correlation analysis of this modulated signal and the ECE data identifies a particular ECE channel associated with the deposition of that gyrotron. Real time equilibrium reconstruction allows the ECE channels to be translated into flux surface and spatial coordinates for use in the feedback loop.

  17. Large-memory real-time multichannel multiplexed pattern recognition

    NASA Technical Reports Server (NTRS)

    Gregory, D. A.; Liu, H. K.

    1984-01-01

    The principle and experimental design of a real-time multichannel multiplexed optical pattern recognition system via use of a 25-focus dichromated gelatin holographic lens (hololens) are described. Each of the 25 foci of the hololens may have a storage and matched filtering capability approaching that of a single-lens correlator. If the space-bandwidth product of an input image is limited, as is true in most practical cases, the 25-focus hololens system has 25 times the capability of a single lens. Experimental results have shown that the interfilter noise is not serious. The system has already demonstrated the storage and recognition of over 70 matched filters - which is a larger capacity than any optical pattern recognition system reported to date.

  18. Real-time lexical comprehension in young children learning American Sign Language.

    PubMed

    MacDonald, Kyle; LaMarr, Todd; Corina, David; Marchman, Virginia A; Fernald, Anne

    2018-04-16

    When children interpret spoken language in real time, linguistic information drives rapid shifts in visual attention to objects in the visual world. This language-vision interaction can provide insights into children's developing efficiency in language comprehension. But how does language influence visual attention when the linguistic signal and the visual world are both processed via the visual channel? Here, we measured eye movements during real-time comprehension of a visual-manual language, American Sign Language (ASL), by 29 native ASL-learning children (16-53 mos, 16 deaf, 13 hearing) and 16 fluent deaf adult signers. All signers showed evidence of rapid, incremental language comprehension, tending to initiate an eye movement before sign offset. Deaf and hearing ASL-learners showed similar gaze patterns, suggesting that the in-the-moment dynamics of eye movements during ASL processing are shaped by the constraints of processing a visual language in real time and not by differential access to auditory information in day-to-day life. Finally, variation in children's ASL processing was positively correlated with age and vocabulary size. Thus, despite competition for attention within a single modality, the timing and accuracy of visual fixations during ASL comprehension reflect information processing skills that are important for language acquisition regardless of language modality. © 2018 John Wiley & Sons Ltd.

  19. Quantitative detection of Lactarius deliciosus extraradical soil mycelium by real-time PCR and its application in the study of fungal persistence and interspecific competition.

    PubMed

    Parladé, J; Hortal, S; Pera, J; Galipienso, L

    2007-01-30

    Real-Time PCR has been applied to quantify extraradical soil mycelium of the edible ectomycorrhizal fungus Lactarius deliciosus in an interspecific competition experiment under greenhouse conditions. Couples of Pinus pinea seedlings inoculated with either L. deliciosus, Rhizopogon roseolus, or non-inoculated (control) were transplanted into pots filled with two types of soil in all the possible combinations. Total DNA was extracted from soil samples at 3 and 6 months after transplantation to perform real-time PCR analysis. DNA extractions from soil mixed with known amounts of mycelium of L. deliciosus were used as standards. Six months after transplantation, the percentage of mycorrhizas of L. deliciosus and seedling growth were significantly affected by the soil type. Extraradical soil mycelium of L. deliciosus was positively correlated with the final percentage of mycorrhizas and significantly affected by the sampling time and soil depth. The competition effect of R. roseolus was not significant for any of the measured parameters, probably due to the sharp decrease of the mycorrhizal colonization by this fungus. We conclude that real-time PCR is a powerful technique for extraradical mycelium quantification in studies aimed at evaluating the persistence of introduced strains of L. deliciosus in field plantations.

  20. Nanopatterning of metal-coated silicon surfaces via ion beam irradiation: Real time x-ray studies reveal the effect of silicide bonding

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    El-Atwani, Osman; Birck Nanotechnology Center, Purdue University, West Lafayette, Indiana 47907; Gonderman, Sean

    We investigated the effect of silicide formation on ion-induced nanopatterning of silicon with various ultrathin metal coatings. Silicon substrates coated with 10 nm Ni, Fe, and Cu were irradiated with 200 eV argon ions at normal incidence. Real time grazing incidence small angle x-ray scattering (GISAXS) and x-ray fluorescence (XRF) were performed during the irradiation process and real time measurements revealed threshold conditions for nanopatterning of silicon at normal incidence irradiation. Three main stages of the nanopatterning process were identified. The real time GISAXS intensity of the correlated peaks in conjunction with XRF revealed that the nanostructures remain for amore » time period after the removal of the all the metal atoms from the sample depending on the binding energy of the metal silicides formed. Ex-situ XPS confirmed the removal of all metal impurities. In-situ XPS during the irradiation of Ni, Fe, and Cu coated silicon substrates at normal incidence demonstrated phase separation and the formation of different silicide phases that occur upon metal-silicon mixing. Silicide formation leads to nanostructure formation due the preferential erosion of the non-silicide regions and the weakening of the ion induced mass redistribution.« less

  1. Novel Real-time Alignment and Calibration of the LHCb detector in Run2

    NASA Astrophysics Data System (ADS)

    Martinelli, Maurizio; LHCb Collaboration

    2017-10-01

    LHCb has introduced a novel real-time detector alignment and calibration strategy for LHC Run2. Data collected at the start of the fill are processed in a few minutes and used to update the alignment parameters, while the calibration constants are evaluated for each run. This procedure improves the quality of the online reconstruction. For example, the vertex locator is retracted and reinserted for stable beam conditions in each fill to be centred on the primary vertex position in the transverse plane. Consequently its position changes on a fill-by-fill basis. Critically, this new real-time alignment and calibration procedure allows identical constants to be used in the online and offline reconstruction, thus improving the correlation between triggered and offline-selected events. This offers the opportunity to optimise the event selection in the trigger by applying stronger constraints. The required computing time constraints are met thanks to a new dedicated framework using the multi-core farm infrastructure for the trigger. The motivation for a real-time alignment and calibration of the LHCb detector is discussed from both the operational and physics performance points of view. Specific challenges of this novel configuration are discussed, as well as the working procedures of the framework and its performance.

  2. Attack tolerance of correlated time-varying social networks with well-defined communities

    NASA Astrophysics Data System (ADS)

    Sur, Souvik; Ganguly, Niloy; Mukherjee, Animesh

    2015-02-01

    In this paper, we investigate the efficiency and the robustness of information transmission for real-world social networks, modeled as time-varying instances, under targeted attack in shorter time spans. We observe that these quantities are markedly higher than that of the randomized versions of the considered networks. An important factor that drives this efficiency or robustness is the presence of short-time correlations across the network instances which we quantify by a novel metric the-edge emergence factor, denoted as ξ. We find that standard targeted attacks are not effective in collapsing this network structure. Remarkably, if the hourly community structures of the temporal network instances are attacked with the largest size community attacked first, the second largest next and so on, the network soon collapses. This behavior, we show is an outcome of the fact that the edge emergence factor bears a strong positive correlation with the size ordered community structures.

  3. Effects of physical randomness training on virtual and laboratory golf putting performance in novices.

    PubMed

    Pataky, T C; Lamb, P F

    2018-06-01

    External randomness exists in all sports but is perhaps most obvious in golf putting where robotic putters sink only 80% of 5 m putts due to unpredictable ball-green dynamics. The purpose of this study was to test whether physical randomness training can improve putting performance in novices. A virtual random-physics golf-putting game was developed based on controlled ball-roll data. Thirty-two subjects were assigned a unique randomness gain (RG) ranging from 0.1 to 2.0-times real-world randomness. Putter face kinematics were measured in 5 m laboratory putts before and after five days of virtual training. Performance was quantified using putt success rate and "miss-adjustment correlation" (MAC), the correlation between left-right miss magnitude and subsequent right-left kinematic adjustments. Results showed no RG-success correlation (r = -0.066, p = 0.719) but mildly stronger correlations with MAC for face angle (r = -0.168, p = 0.358) and clubhead path (r = -0.302, p = 0.093). The strongest RG-MAC correlation was observed during virtual training (r = -0.692, p < 0.001). These results suggest that subjects quickly adapt to physical randomness in virtual training, and also that this learning may weakly transfer to real golf putting kinematics. Adaptation to external physical randomness during virtual training may therefore help golfers adapt to external randomness in real-world environments.

  4. Impact of Autocorrelation on Functional Connectivity

    PubMed Central

    Arbabshirani, Mohammad R.; Damaraju, Eswar; Phlypo, Ronald; Plis, Sergey; Allen, Elena; Ma, Sai; Mathalon, Daniel; Preda, Adrian; Vaidya, Jatin G.; Adali, Tülay; Calhoun, Vince D.

    2014-01-01

    Although the impact of serial correlation (autocorrelation) in residuals of general linear models for fMRI time-series has been studied extensively, the effect of autocorrelation on functional connectivity studies has been largely neglected until recently. Some recent studies based on results from economics have questioned the conventional estimation of functional connectivity and argue that not correcting for autocorrelation in fMRI time-series results in “spurious” correlation coefficients. In this paper, first we assess the effect of autocorrelation on Pearson correlation coefficient through theoretical approximation and simulation. Then we present this effect on real fMRI data. To our knowledge this is the first work comprehensively investigating the effect of autocorrelation on functional connectivity estimates. Our results show that although FC values are altered, even following correction for autocorrelation, results of hypothesis testing on FC values remain very similar to those before correction. In real data we show this is true for main effects and also for group difference testing between healthy controls and schizophrenia patients. We further discuss model order selection in the context of autoregressive processes, effects of frequency filtering and propose a preprocessing pipeline for connectivity studies. PMID:25072392

  5. Real-time MR imaging of adeno-associated viral vector delivery to the primate brain

    PubMed Central

    Fiandaca, Massimo S.; Varenika, Vanja; Eberling, Jamie; McKnight, Tracy; Bringas, John; Pivirotto, Phillip; Beyer, Janine; Hadaczek, Piotr; Bowers, William; Park, John; Federoff, Howard; Forsayeth, John; Bankiewicz, Krystof S.

    2009-01-01

    We are developing a method for real-time magnetic resonance imaging (MRI) visualization of convection-enhanced delivery (CED) of adeno-associated viral vectors (AAV) to the primate brain. By including gadolinium-loaded liposomes (GDL) with AAV, we can track the convective movement of viral particles by continuous monitoring of distribution of surrogate GDL. In order to validate this approach, we infused two AAV (AAV1-GFP and AAV2-hAADC) into three different regions of non-human primate brain (corona radiata, putamen, and thalamus). The procedure was tolerated well by all three animals in the study. The distribution of GFP determined by immunohistochemistry in both brain regions correlated closely with distribution of GDL determined by MRI. Co-distribution was weaker with AAV2-hAADC, although in vivo PET scanning with FMT for AADC activity correlated well with immunohistochemistry of AADC. Although this is a relatively small study, it appears that AAV1 correlates better with MRI-monitored delivery than does AAV2. It seems likely that the difference in distribution may be due to differences in tissue specificity of the two serotypes. PMID:19095069

  6. Correlator data analysis for the array feed compensation system

    NASA Technical Reports Server (NTRS)

    Iijima, B.; Fort, D.; Vilnrotter, V.

    1994-01-01

    The real-time array feed compensation system is currently being evaluated at DSS 13. This system recovers signal-to-noise ratio (SNR) loss due to mechanical antenna deformations by using an array of seven Ka-band (33.7-GHz) horns to collect the defocused signal fields. The received signals are downconverted and digitized, in-phase and quadrature samples are generated, and combining weights are applied before the samples are recombined. It is shown that when optimum combining weights are employed, the SNR of the combined signal approaches the sum of the channel SNR's. The optimum combining weights are estimated directly from the signals in each channel by the Real-Time Block 2 (RTB2) correlator; since it was designed for very-long-baseline interferometer (VLBI) applications, it can process broadband signals as well as tones to extract the required weight estimates. The estimation algorithms for the optimum combining weights are described for tones and broadband sources. Data recorded in correlator output files can also be used off-line to estimate combiner performance by estimating the SNR in each channel, which was done for data taken during a Jupiter track at DSS 13.

  7. Detection of five potentially periodontal pathogenic bacteria in peri-implant disease: A comparison of PCR and real-time PCR.

    PubMed

    Schmalz, Gerhard; Tsigaras, Sandra; Rinke, Sven; Kottmann, Tanja; Haak, Rainer; Ziebolz, Dirk

    2016-07-01

    The aim of this study was to compare the microbial analysis methods of polymerase chain reaction (PCR) and real-time PCR (RT-PCR) in terms of detection of five selected potentially periodontal pathogenic bacteria in peri-implant disease. Therefore 45 samples of healthy, mucositis and peri-implantitis (n = 15 each) were assessed according to presence of the following bacteria using PCR (DNA-strip technology) and RT-PCR (fluorescent dye SYBR green-system): Aggregatibacter actinomycetemcomitans (Aa), Porphyromonas gingivalis (Pg), Treponema denticola (Td), Tanerella forsythia (Tf), and Fusobacterium nucleatum (Fn). There were no significant correlations between the bacterial and disease patterns, so the benefit of using microbiological tests for the diagnosis of peri-implant diseases is questionable. Correlations between the methods were highest for Tf (Kendall's Tau: 0.65, Spearman: 0.78), Fn (0.49, 0.61) and Td (0.49, 0.59). For Aa (0.38, 0.42) and Pg (0.04, 0.04), lower correlation values were detected. Accordingly, conventional semi-quantitative PCR seems to be sufficient for analyzing potentially periodontal pathogenic bacterial species. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Spring thaw predictor & development of real time spring load restrictions.

    DOT National Transportation Integrated Search

    2011-02-01

    This report summarizes the results of a study to develop a correlation between weather forecasts and the : spring thaw in order to reduce the duration of load limits on New Hampshire roadways. The study used a falling : weight deflectometer at 10 sit...

  9. Efficacy of the detection of Legionella in hot and cold water samples by culture and PCR. I. Standardization of methods.

    PubMed

    Wójcik-Fatla, Angelina; Stojek, Nimfa Maria; Dutkiewicz, Jacek

    2012-01-01

    The aim of the present study was: - to compare methods for concentration and isolation of Legionella DNA from water; - to examine the efficacy of various modifications of PCR test (PCR, semi-nested PCR, and real-time PCR) for the detection of known numbers of Legionella pneumophila in water samples artificially contaminated with the strain of this bacterium and in randomly selected samples of environmental water, in parallel with examination by culture. It was found that filtration is much more effective than centrifugation for the concentration of DNA in water samples, and that the Qiamp DNA Mini-Kit is the most efficient for isolation of Legionella DNA from water. The semi-nested PCR and real-time PCR proved to be the most sensitive methods for detection of Legionella DNA in water samples. Both PCR modifications showed a high correlation with recovery of Legionella by culture (p<0.01), while no correlation occurred between the results of one-stage PCR and culture (p>0.1).

  10. Computer-aided diagnosis of colorectal polyp histology by using a real-time image recognition system and narrow-band imaging magnifying colonoscopy.

    PubMed

    Kominami, Yoko; Yoshida, Shigeto; Tanaka, Shinji; Sanomura, Yoji; Hirakawa, Tsubasa; Raytchev, Bisser; Tamaki, Toru; Koide, Tetsusi; Kaneda, Kazufumi; Chayama, Kazuaki

    2016-03-01

    It is necessary to establish cost-effective examinations and treatments for diminutive colorectal tumors that consider the treatment risk and surveillance interval after treatment. The Preservation and Incorporation of Valuable Endoscopic Innovations (PIVI) committee of the American Society for Gastrointestinal Endoscopy published a statement recommending the establishment of endoscopic techniques that practice the resect and discard strategy. The aims of this study were to evaluate whether our newly developed real-time image recognition system can predict histologic diagnoses of colorectal lesions depicted on narrow-band imaging and to satisfy some problems with the PIVI recommendations. We enrolled 41 patients who had undergone endoscopic resection of 118 colorectal lesions (45 nonneoplastic lesions and 73 neoplastic lesions). We compared the results of real-time image recognition system analysis with that of narrow-band imaging diagnosis and evaluated the correlation between image analysis and the pathological results. Concordance between the endoscopic diagnosis and diagnosis by a real-time image recognition system with a support vector machine output value was 97.5% (115/118). Accuracy between the histologic findings of diminutive colorectal lesions (polyps) and diagnosis by a real-time image recognition system with a support vector machine output value was 93.2% (sensitivity, 93.0%; specificity, 93.3%; positive predictive value (PPV), 93.0%; and negative predictive value, 93.3%). Although further investigation is necessary to establish our computer-aided diagnosis system, this real-time image recognition system may satisfy the PIVI recommendations and be useful for predicting the histology of colorectal tumors. Copyright © 2016 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  11. Validation of Geno-Sen's Scrub Typhus Real Time Polymerase Chain Reaction Kit by its Comparison with a Serological ELISA Test

    PubMed Central

    Anitharaj, Velmurugan; Stephen, Selvaraj; Pradeep, Jothimani; Pooja, Pratheesh; Preethi, Sridharan

    2017-01-01

    Background: In the recent past, scrub typhus (ST) has been reported from different parts of India, based on Weil-Felix/enzyme-linked immunosorbent assay (ELISA)/indirect immunofluorescence assay (IFA). Molecular tests are applied only by a few researchers. Aims: Evaluation of a new commercial real time polymerase chain reaction (PCR) kit for molecular diagnosis of ST by comparing it with the commonly used IgM ELISA is our aim. Settings and Design: ST has been reported all over India including Puducherry and surrounding Tamil Nadu and identified as endemic for ST. This study was designed to correlate antibody detection by IgM ELISA and Orientia tsutsugamushi DNA in real time PCR. Materials and Methods: ST IgM ELISA (InBios Inc., USA) was carried out for 170 consecutive patients who presented with the symptoms of acute ST during 11 months (November, 2015– September, 2016). All 77 of these patients with IgM ELISA positivity and 49 of 93 IgM ELISA negative patients were subjected to real time PCR (Geno-Sen's ST real time PCR, Himachal Pradesh, India). Statistical Analysis: Statistical analysis for clinical and laboratory results was performed using IBM SPSS Statistics 17 for Windows (SPSS Inc., Chicago, USA). Chi-square test with Yates correction (Fisher's test) was employed for a small number of samples. Results and Conclusion: Among 77 suspected cases of acute ST with IgM ELISA positivity and 49 IgM negative patients, 42 and 7 were positive, respectively, for O. tsutsugamushi 56-kDa type-specific gene in real time PCR kit. Until ST IFA, the gold standard diagnostic test, is properly validated in India, diagnosis of acute ST will depend on both ELISA and quantitative PCR. PMID:28878522

  12. Validation of Geno-Sen's Scrub Typhus Real Time Polymerase Chain Reaction Kit by its Comparison with a Serological ELISA Test.

    PubMed

    Anitharaj, Velmurugan; Stephen, Selvaraj; Pradeep, Jothimani; Pooja, Pratheesh; Preethi, Sridharan

    2017-01-01

    In the recent past, scrub typhus (ST) has been reported from different parts of India, based on Weil-Felix/enzyme-linked immunosorbent assay (ELISA)/indirect immunofluorescence assay (IFA). Molecular tests are applied only by a few researchers. Evaluation of a new commercial real time polymerase chain reaction (PCR) kit for molecular diagnosis of ST by comparing it with the commonly used IgM ELISA is our aim. ST has been reported all over India including Puducherry and surrounding Tamil Nadu and identified as endemic for ST. This study was designed to correlate antibody detection by IgM ELISA and Orientia tsutsugamushi DNA in real time PCR. ST IgM ELISA (InBios Inc., USA) was carried out for 170 consecutive patients who presented with the symptoms of acute ST during 11 months (November, 2015- September, 2016). All 77 of these patients with IgM ELISA positivity and 49 of 93 IgM ELISA negative patients were subjected to real time PCR (Geno-Sen's ST real time PCR, Himachal Pradesh, India). Statistical analysis for clinical and laboratory results was performed using IBM SPSS Statistics 17 for Windows (SPSS Inc., Chicago, USA). Chi-square test with Yates correction (Fisher's test) was employed for a small number of samples. Among 77 suspected cases of acute ST with IgM ELISA positivity and 49 IgM negative patients, 42 and 7 were positive, respectively, for O. tsutsugamushi 56-kDa type-specific gene in real time PCR kit. Until ST IFA, the gold standard diagnostic test, is properly validated in India, diagnosis of acute ST will depend on both ELISA and quantitative PCR.

  13. Real-Time PCR Analysis of Vibrio vulnificus from Oysters

    PubMed Central

    Campbell, Mark S.; Wright, Anita C.

    2003-01-01

    Vibrio vulnificus is an opportunistic human pathogen commonly found in estuarine environments. Infections are associated with raw oyster consumption and can produce rapidly fatal septicemia in susceptible individuals. Standard enumeration of this organism in shellfish or seawater is laborious and inaccurate; therefore, more efficient assays are needed. An oligonucleotide probe derived from the cytolysin gene, vvhA, was previously used for colony hybridizations to enumerate V. vulnificus. However, this method requires overnight growth, and vibrios may lack culturability under certain conditions. In the present study, we targeted the same locus for development of a TaqMan real-time PCR assay. Probe specificity was confirmed by amplification of 28 V. vulnificus templates and by the lack of a PCR product with 22 non-V. vulnificus strains. Detection of V. vulnificus in pure cultures was observed over a 6-log-unit linear range of concentration (102 to 108 CFU ml−1), with a lower limit of 72 fg of genomic DNA μl of PCR mixture−1 or the equivalent of six cells. Similar sensitivity was observed in DNA extracted from mixtures of V. vulnificus and V. parahaemolyticus cells. Real-time PCR enumeration of artificially inoculated oyster homogenates correlated well with colony hybridization counts (r2 = 0.97). Numbers of indigenous V. vulnificus cells in oysters by real-time PCR showed no significant differences from numbers from plate counts with probe (t test; P = 0.43). Viable but nonculturable cells were also enumerated by real-time PCR and confirmed by the BacLight viability assay. These data indicate that real-time PCR can provide sensitive species-specific detection and enumeration of V. vulnificus in seafood. PMID:14660359

  14. Evaluation of non-extracted genital swabs for real-time HSV PCR.

    PubMed

    Miari, Victoria F; Wall, Gavin R; Clark, Duncan A

    2015-01-01

    Nucleic acid extraction of clinical samples is accepted as a key requirement in molecular diagnostics. At Barts Health NHS Trust, swabs taken from patients with clinical suspicion of HSV infection were routinely extracted on the Qiagen MDx BioRobot prior to testing with a real-time triplex PCR for HSV1, HSV2, and VZV. The aim of this study was to adapt an existing HSV1/HSV2/VZV real-time PCR by replacing VZV with phocine herpesvirus 1 (PhHV) as an internal control (IC) and evaluate whether this adapted assay required the nucleic acid extraction step for predominantly genital swabs. First 313 non-extracted and extracted swabs were tested in parallel with the existing triplex HSV1/HSV2/VZV real-time PCR. The second stage involved testing 176 non-extracted swabs using a triplex real-time PCR for HSV1, HSV2, and PhHV and comparing the results with the samples extracted and tested by the original triplex assay. The results correlated well when the existing assay was used, with only three non-extracted samples that would have been reported as negative compared to the extracted sample result (Cq s 33, 39, 35-two samples HSV1, one sample HSV2). In the evaluation using the adapted assay containing the IC, two of 176 samples were discordant, where a HSV negative non-extracted sample result would have been reported differently to the extracted sample result (Cq s 32, 33-both HSV1). This study demonstrated that it is feasible to test non-extracted swabs for HSV in a real-time PCR that includes an IC. J. Med. Virol. 87: 125-129, 2015. © 2014 Wiley Periodicals, Inc. © 2014 Wiley Periodicals, Inc.

  15. Identification by real-time PCR with SYBR Green of Leishmania spp. and Serratia marcescens in canine 'sterile' cutaneous nodular lesions.

    PubMed

    Cornegliani, Luisa; Corona, Antonio; Vercelli, Antonella; Roccabianca, Paola

    2015-06-01

    Noninfectious, non-neoplastic, nodular to diffuse, so-called 'sterile' granulomatous/pyogranulomatous skin lesions (SGPSLs) are infrequently identified in dogs and may represent a diagnostic challenge. Their correct identification is based on history, histopathology and absence of intralesional foreign bodies and micro-organisms. The aim of this study was to investigate the presence of Leishmania spp., Mycobacterium spp., Serratia marcescens and Nocardia spp. by real-time PCR in canine nodular skin lesions histologically diagnosed as putatively sterile. Formalin-fixed skin biopsies were collected from 40 dogs. All samples were associated with an SGPSL diagnosis characterized by multifocal, nodular to diffuse, periadnexal and perifollicular pyogranulomas/granulomas. Neither micro-organisms nor foreign bodies were detected with haematoxylin and eosin staining, under polarized light. Further analyses included periodic acid Schiff, Ziehl-Neelsen, Fite Faraco, Giemsa and Gram histochemical stains; anti-Bacillus Calmette-Guérin (BCG) and Leishmania spp. immunohistochemistry; and real-time PCR analysis for Leishmania spp., Mycobacterium spp., S. marcescens and Nocardia spp. Special stains and BCG/immunohistochemistry were negative in all samples. Real-time PCR was positive for Leishmania spp. in four of 40 biopsies and for S. marcescens in two of 40 samples. Real-time PCR for Mycobacterium spp. and Nocardia spp. was negative. No correlation between real-time PCR positivity and a specific histological pattern was identified. Leishmania spp. have been previously identified as possible agents of certain SGPSLs, while the involvement of S. marcescens has not been investigated previously. According to our findings, Serratia spp. should be included in the list of agents possibly associated with a subgroup of granulomatous/pyogranulomatous skin lesions in dogs. © 2015 ESVD and ACVD.

  16. Simultaneous real-time monitoring of multiple cortical systems.

    PubMed

    Gupta, Disha; Jeremy Hill, N; Brunner, Peter; Gunduz, Aysegul; Ritaccio, Anthony L; Schalk, Gerwin

    2014-10-01

    Real-time monitoring of the brain is potentially valuable for performance monitoring, communication, training or rehabilitation. In natural situations, the brain performs a complex mix of various sensory, motor or cognitive functions. Thus, real-time brain monitoring would be most valuable if (a) it could decode information from multiple brain systems simultaneously, and (b) this decoding of each brain system were robust to variations in the activity of other (unrelated) brain systems. Previous studies showed that it is possible to decode some information from different brain systems in retrospect and/or in isolation. In our study, we set out to determine whether it is possible to simultaneously decode important information about a user from different brain systems in real time, and to evaluate the impact of concurrent activity in different brain systems on decoding performance. We study these questions using electrocorticographic signals recorded in humans. We first document procedures for generating stable decoding models given little training data, and then report their use for offline and for real-time decoding from 12 subjects (six for offline parameter optimization, six for online experimentation). The subjects engage in tasks that involve movement intention, movement execution and auditory functions, separately, and then simultaneously. Main Results: Our real-time results demonstrate that our system can identify intention and movement periods in single trials with an accuracy of 80.4% and 86.8%, respectively (where 50% would be expected by chance). Simultaneously, the decoding of the power envelope of an auditory stimulus resulted in an average correlation coefficient of 0.37 between the actual and decoded power envelopes. These decoders were trained separately and executed simultaneously in real time. This study yielded the first demonstration that it is possible to decode simultaneously the functional activity of multiple independent brain systems. Our comparison of univariate and multivariate decoding strategies, and our analysis of the influence of their decoding parameters, provides benchmarks and guidelines for future research on this topic.

  17. Fully Automated Quantification of Cytomegalovirus (CMV) in Whole Blood with the New Sensitive Abbott RealTime CMV Assay in the Era of the CMV International Standard

    PubMed Central

    Schnepf, Nathalie; Scieux, Catherine; Resche-Riggon, Matthieu; Feghoul, Linda; Xhaard, Alienor; Gallien, Sébastien; Molina, Jean-Michel; Socié, Gérard; Viglietti, Denis; Simon, François; Mazeron, Marie-Christine

    2013-01-01

    Fully standardized reproducible and sensitive quantification assays for cytomegalovirus (CMV) are needed to better define thresholds for antiviral therapy initiation and interruption. We evaluated the newly released Abbott RealTime CMV assay for CMV quantification in whole blood (WB) that includes automated extraction and amplification (m2000 RealTime system). Sensitivity, accuracy, linearity, and intra- and interassay variability were validated in a WB matrix using Quality Control for Molecular Diagnostics (QCMD) panels and the WHO international standard (IS). The intra- and interassay coefficients of variation were 1.37% and 2.09% at 5 log10 copies/ml and 2.41% and 3.80% at 3 log10 copies/ml, respectively. According to expected values for the QCMD and Abbott RealTime CMV methods, the lower limits of quantification were 104 and <50 copies/ml, respectively. The conversion factor between international units and copies (2.18), determined from serial dilutions of the WHO IS in WB, was significantly different from the factor provided by the manufacturer (1.56) (P = 0.001). Results from 302 clinical samples were compared with those from the Qiagen artus CMV assay on the same m2000 RealTime system. The two assays provided highly concordant results (concordance correlation coefficient, 0.92), but the Abbott RealTime CMV assay detected and quantified, respectively, 20.6% and 47.8% more samples than the Qiagen/artus CMV assay. The sensitivity and reproducibility of the results, along with the automation, fulfilled the quality requirements for implementation of the Abbott RealTime CMV assay in clinical settings. Our results highlight the need for careful validation of conversion factors provided by the manufacturers for the WHO IS in WB to allow future comparison of results obtained with different assays. PMID:23616450

  18. Simultaneous Real-Time Monitoring of Multiple Cortical Systems

    PubMed Central

    Gupta, Disha; Hill, N. Jeremy; Brunner, Peter; Gunduz, Aysegul; Ritaccio, Anthony L.; Schalk, Gerwin

    2014-01-01

    Objective Real-time monitoring of the brain is potentially valuable for performance monitoring, communication, training or rehabilitation. In natural situations, the brain performs a complex mix of various sensory, motor, or cognitive functions. Thus, real-time brain monitoring would be most valuable if (a) it could decode information from multiple brain systems simultaneously, and (b) this decoding of each brain system were robust to variations in the activity of other (unrelated) brain systems. Previous studies showed that it is possible to decode some information from different brain systems in retrospect and/or in isolation. In our study, we set out to determine whether it is possible to simultaneously decode important information about a user from different brain systems in real time, and to evaluate the impact of concurrent activity in different brain systems on decoding performance. Approach We study these questions using electrocorticographic (ECoG) signals recorded in humans. We first document procedures for generating stable decoding models given little training data, and then report their use for offline and for real-time decoding from 12 subjects (6 for offline parameter optimization, 6 for online experimentation). The subjects engage in tasks that involve movement intention, movement execution and auditory functions, separately, and then simultaneously. Main results Our real-time results demonstrate that our system can identify intention and movement periods in single trials with an accuracy of 80.4% and 86.8%, respectively (where 50% would be expected by chance). Simultaneously, the decoding of the power envelope of an auditory stimulus resulted in an average correlation coefficient of 0.37 between the actual and decoded power envelope. These decoders were trained separately and executed simultaneously in real time. Significance This study yielded the first demonstration that it is possible to decode simultaneously the functional activity of multiple independent brain systems. Our comparison of univariate and multivariate decoding strategies, and our analysis of the influence of their decoding parameters, provides benchmarks and guidelines for future research on this topic. PMID:25080161

  19. Real-time microstructural and functional imaging and image processing in optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Westphal, Volker

    Optical Coherence Tomography (OCT) is a noninvasive optical imaging technique that allows high-resolution cross-sectional imaging of tissue microstructure, achieving a spatial resolution of about 10 mum. OCT is similar to B-mode ultrasound (US) except that it uses infrared light instead of ultrasound. In contrast to US, no coupling gel is needed, simplifying the image acquisition. Furthermore, the fiber optic implementation of OCT is compatible with endoscopes. In recent years, the transition from slow imaging, bench-top systems to real-time clinical systems has been under way. This has lead to a variety of applications, namely in ophthalmology, gastroenterology, dermatology and cardiology. First, this dissertation will demonstrate that OCT is capable of imaging and differentiating clinically relevant tissue structures in the gastrointestinal tract. A careful in vitro correlation study between endoscopic OCT images and corresponding histological slides was performed. Besides structural imaging, OCT systems were further developed for functional imaging, as for example to visualize blood flow. Previously, imaging flow in small vessels in real-time was not possible. For this research, a new processing scheme similar to real-time Doppler in US was introduced. It was implemented in dedicated hardware to allow real-time acquisition and overlayed display of blood flow in vivo. A sensitivity of 0.5mm/s was achieved. Optical coherence microscopy (OCM) is a variation of OCT, improving the resolution even further to a few micrometers. Advances made in the OCT scan engine for the Doppler setup enabled real-time imaging in vivo with OCM. In order to generate geometrical correct images for all the previous applications in real-time, extensive image processing algorithms were developed. Algorithms for correction of distortions due to non-telecentric scanning, nonlinear scan mirror movements, and refraction were developed and demonstrated. This has led to interesting new applications, as for example in imaging of the anterior segment of the eye.

  20. Use of MV and kV imager correlation for maintaining continuous real-time 3D internal marker tracking during beam interruptions

    NASA Astrophysics Data System (ADS)

    Wiersma, R. D.; Riaz, N.; Dieterich, Sonja; Suh, Yelin; Xing, L.

    2009-01-01

    The integration of onboard kV imaging together with a MV electronic portal imaging device (EPID) on linear accelerators (LINAC) can provide an easy to implement real-time 3D organ position monitoring solution for treatment delivery. Currently, real-time MV-kV tracking has only been demonstrated by simultaneous imagining by both MV and kV imaging devices. However, modalities such as step-and-shoot IMRT (SS-IMRT), which inherently contain MV beam interruptions, can lead to loss of target information necessary for 3D localization. Additionally, continuous kV imaging throughout the treatment delivery can lead to high levels of imaging dose to the patient. This work demonstrates for the first time how full 3D target tracking can be maintained even in the presence of such beam interruption, or MV/kV beam interleave, by use of a relatively simple correlation model together with MV-kV tracking. A moving correlation model was constructed using both present and prior positions of the marker in the available MV or kV image to compute the position of the marker on the interrupted imager. A commercially available radiotherapy system, equipped with both MV and kV imaging devices, was used to deliver typical SS-IMRT lung treatment plans to a 4D phantom containing internally embedded metallic markers. To simulate actual lung tumor motion, previous recorded 4D lung patient motion data were used. Lung tumor motion data of five separate patients were inputted into the 4D phantom, and typical SS-IMRT lung plans were delivered to simulate actual clinical deliveries. Application of the correlation model to SS-IMRT lung treatment deliveries was found to be an effective solution for maintaining continuous 3D tracking during 'step' beam interruptions. For deliveries involving five or more gantry angles with 50 or more fields per plan, the positional errors were found to have <=1 mm root mean squared error (RMSE) in all three spatial directions. In addition to increasing the robustness of MV-kV tracking against beam interruption, it was also found that use of correlation can be an effective way of lowering kV dose to the patient and for increasing kV image quality by reduction of MV scatter interference.

  1. An ISEE 3 high time resolution study of interplanetary parameter correlations with magnetospheric activity

    NASA Technical Reports Server (NTRS)

    Baker, D. N.; Zwickl, R. D.; Bame, S. J.; Hones, E. W., Jr.; Tsurutani, B. T.; Smith, E. J.; Akasofu, S.-I.

    1983-01-01

    The coupling between the solar wind and the geomagnetic disturbances was examined using data from the ISEE-3 spacecraft at an earth-sun libration point and ground-based data. One minute data were used to avoid aliasing in determining the internal magnetospheric response to solar wind conditions. Attention was given to the cross-correlations between the geomagnetic index (AE), the total energy dissipation rate (UT), and the solar wind parameters, as well as the spatial and temporal scales on which the magnetosphere reacts to the solar wind conditions. It was considered necessary to characterize the physics of the solar wind-magnetosphere coupling in order to define the requirements for a spacecraft like the ISEE-3 that could be used as a real time monitoring system for predicting storms and substorms. The correlations among all but one parameter were lower during disturbance intervals; UT was highly correlated with all parameters during the disturbed times. An intrinsic 25-40 min delay was detected between interplanetary activity and magnetospheric response in quite times, diminishing to no more than 15 min during disturbed times.

  2. Low Computational Signal Acquisition for GNSS Receivers Using a Resampling Strategy and Variable Circular Correlation Time

    PubMed Central

    Zhang, Yeqing; Wang, Meiling; Li, Yafeng

    2018-01-01

    For the objective of essentially decreasing computational complexity and time consumption of signal acquisition, this paper explores a resampling strategy and variable circular correlation time strategy specific to broadband multi-frequency GNSS receivers. In broadband GNSS receivers, the resampling strategy is established to work on conventional acquisition algorithms by resampling the main lobe of received broadband signals with a much lower frequency. Variable circular correlation time is designed to adapt to different signal strength conditions and thereby increase the operation flexibility of GNSS signal acquisition. The acquisition threshold is defined as the ratio of the highest and second highest correlation results in the search space of carrier frequency and code phase. Moreover, computational complexity of signal acquisition is formulated by amounts of multiplication and summation operations in the acquisition process. Comparative experiments and performance analysis are conducted on four sets of real GPS L2C signals with different sampling frequencies. The results indicate that the resampling strategy can effectively decrease computation and time cost by nearly 90–94% with just slight loss of acquisition sensitivity. With circular correlation time varying from 10 ms to 20 ms, the time cost of signal acquisition has increased by about 2.7–5.6% per millisecond, with most satellites acquired successfully. PMID:29495301

  3. Low Computational Signal Acquisition for GNSS Receivers Using a Resampling Strategy and Variable Circular Correlation Time.

    PubMed

    Zhang, Yeqing; Wang, Meiling; Li, Yafeng

    2018-02-24

    For the objective of essentially decreasing computational complexity and time consumption of signal acquisition, this paper explores a resampling strategy and variable circular correlation time strategy specific to broadband multi-frequency GNSS receivers. In broadband GNSS receivers, the resampling strategy is established to work on conventional acquisition algorithms by resampling the main lobe of received broadband signals with a much lower frequency. Variable circular correlation time is designed to adapt to different signal strength conditions and thereby increase the operation flexibility of GNSS signal acquisition. The acquisition threshold is defined as the ratio of the highest and second highest correlation results in the search space of carrier frequency and code phase. Moreover, computational complexity of signal acquisition is formulated by amounts of multiplication and summation operations in the acquisition process. Comparative experiments and performance analysis are conducted on four sets of real GPS L2C signals with different sampling frequencies. The results indicate that the resampling strategy can effectively decrease computation and time cost by nearly 90-94% with just slight loss of acquisition sensitivity. With circular correlation time varying from 10 ms to 20 ms, the time cost of signal acquisition has increased by about 2.7-5.6% per millisecond, with most satellites acquired successfully.

  4. Performance of real-time strain elastography, transient elastography, and aspartate-to-platelet ratio index in the assessment of fibrosis in chronic hepatitis C.

    PubMed

    Ferraioli, Giovanna; Tinelli, Carmine; Malfitano, Antonello; Dal Bello, Barbara; Filice, Gaetano; Filice, Carlo; Above, Elisabetta; Barbarini, Giorgio; Brunetti, Enrico; Calderon, Willy; Di Gregorio, Marta; Lissandrin, Raffaella; Ludovisi, Serena; Maiocchi, Laura; Michelone, Giuseppe; Mondelli, Mario; Patruno, Savino F A; Perretti, Alessandro; Poma, Gianluigi; Sacchi, Paolo; Zaramella, Marco; Zicchetti, Mabel

    2012-07-01

    The purpose of this article is to evaluate the diagnostic performance of transient elastography, real-time strain elastography, and aspartate-to-platelet ratio index in assessing fibrosis in patients with chronic hepatitis C by using histologic Metavir scores as reference standard. Consecutive patients with chronic hepatitis C scheduled for liver biopsy were enrolled. Liver biopsy was performed on the same day as transient elastography and real-time strain elastography. Transient elastography and real-time strain elastography were performed in the same patient encounter by a single investigator using a medical device based on elastometry and an ultrasound machine, respectively. Diagnostic performance was assessed by using receiver operating characteristic curves and area under the receiver operating characteristic curve (AUC) analysis. One hundred thirty patients (91 men and 39 women) were analyzed. The cutoff values for transient elastography, real-time strain elastography, and aspartate-to-platelet ratio index were 6.9 kPa, 1.82, and 0.37, respectively, for fibrosis score of 2 or higher; 7.3 kPa, 1.86, and 0.70, respectively, for fibrosis score of 3 or higher; and 9.3 kPa, 2.33, and 0.70, respectively, for fibrosis score of 4. AUC values of transient elastography, real-time strain elastography, aspartate-to-platelet ratio index were 0.88, 0.74, and 0.86, respectively, for fibrosis score of 2 or higher; 0.95, 0.80, and 0.89, respectively, for fibrosis score of 3 or higher; and 0.97, 0.80, and 0.84, respectively, for fibrosis score of 4. A combination of the three methods, when two of three were in agreement, showed AUC curves of 0.93, 0.95, and 0.95 for fibrosis scores of 2 or higher, 3 or higher, and 4, respectively. Transient elastography, real-time strain elastography, and aspartate-to-platelet ratio index values were correlated with histologic stages of fibrosis. Transient elastography offered excellent diagnostic performance in assessing severe fibrosis and cirrhosis. Real-time elastography does not yet have the potential to substitute for transient elastography in the assessment of liver fibrosis.

  5. Real-time prediction of mediastinal lymph node malignancy by endobronchial ultrasound.

    PubMed

    Shafiek, Hanaa; Fiorentino, Federico; Peralta, Alejandro David; Serra, Enrique; Esteban, Blanca; Martinez, Rocío; Noguera, Maria Angels; Moyano, Pere; Sala, Ernest; Sauleda, Jaume; Cosío, Borja G

    2014-06-01

    To evaluate the utility of different ultrasonographic (US) features in differentiating benign and malignant lymph node (LN) by endobronchial ultrasound (EBUS) and validate a score for real-time clinical application. 208 mediastinal LN acquired from 141 patients were analyzed. Six different US criteria were evaluated (short axis ≥10 mm, shape, margin, echogenicity, and central hilar structure [CHS], and presence of hyperechoic density) by two observers independently. A simplified score was generated where the presence of margin distinction, round shape and short axis ≥10 mm were scored as 1 and heterogeneous echogenicity and absence of CHS were scored as 1.5. The score was evaluated prospectively for real-time clinical application in 65 LN during EBUS procedure in 39 patients undertaken by two experienced operators. These criteria were correlated with the histopathological results and the sensitivity, specificity, positive and negative predictive values (PPV and NPV) were calculated. Both heterogenicity and absence of CHS had the highest sensitivity and NPV (≥90%) for predicting LN malignancy with acceptable inter-observer agreement (92% and 87% respectively). On real-time application, the sensitivity and specificity of the score >5 were 78% and 86% respectively; only the absence of CHS, round shape and size of LN were significantly associated with malignant LN. Combination of different US criteria can be useful for prediction of mediastinal LN malignancy and valid for real-time clinical application. Copyright © 2013 SEPAR. Published by Elsevier Espana. All rights reserved.

  6. Analytical Performances of Human Immunodeficiency Virus Type 1 RNA-Based Amplix® Real-Time PCR Platform for HIV-1 RNA Quantification

    PubMed Central

    Mboumba Bouassa, Ralph-Sydney; Jenabian, Mohammad-Ali; Wolyec, Serge Tonen; Robin, Leman; Matta, Mathieu; Longo, Jean de Dieu; Grésenguet, Gérard; Andreoletti, Laurent; Bélec, Laurent

    2016-01-01

    Objectives. We evaluated the performances of Amplix real-time PCR platform developed by Biosynex (Strasbourg, France), combining automated station extraction (Amplix station 16 Dx) and real-time PCR (Amplix NG), for quantifying plasma HIV-1 RNA by lyophilized HIV-1 RNA-based Amplix reagents targeting gag and LTR, using samples from HIV-1-infected adults from Central African Republic. Results. Amplix real-time PCR assay showed low limit of detection (28 copies/mL), across wide dynamic range (1.4–10 log copies/mL), 100% sensitivity and 99% specificity, high reproducibility, and accuracy with mean bias < 5%. The assay showed excellent correlations and concordance of 95.3% with the reference HIV-1 RNA load assay (Roche), with mean absolute bias of +0.097 log copies/mL by Bland-Altman analysis. The assay was able to detect and quantify the most prevalent HIV-1 subtype strains and the majority of non-B subtypes, CRFs of HIV-1 group M, and HIV-1 groups N and O circulating in Central Africa. The Amplix assay showed 100% sensitivity and 99.6% specificity to diagnose virological failure in clinical samples from antiretroviral drug-experienced patients. Conclusions. The HIV-1 RNA-based Amplix real-time PCR platform constitutes sensitive and reliable system for clinical monitoring of HIV-1 RNA load in HIV-1-infected children and adults, particularly adapted to intermediate laboratory facilities in sub-Saharan Africa. PMID:28050283

  7. Whole blood Nested PCR and Real-time PCR amplification of Talaromyces marneffei specific DNA for diagnosis.

    PubMed

    Lu, Sha; Li, Xiqing; Calderone, Richard; Zhang, Jing; Ma, Jianchi; Cai, Wenying; Xi, Liyan

    2016-02-01

    Talaromyces marneffei is a dimorphic pathogenic fungus, which is a life-threatening invasive mycosis in the immunocompromised host. Prompt diagnosis of T. marneffei infection remains difficult although there has been progress in attempts to expedite the diagnosis of this infection. We previously demonstrated the value of nested polymerase chain reaction (PCR) to detect T. marneffei in paraffin embedded tissue samples with high sensitivity and specificity. In this study, this assay was used to detect the DNA of T. marneffei in whole blood samples. Real-time PCR assay was also evaluated to identify T. marneffei in the same samples. Twenty out of 30 whole blood samples (67%) collected from 23 patients were found positive by using the nested PCR assay, while 23/30 (77%) samples were found positive by using the real-time PCR assay. In order to express accurately the fungal loads, we used a normalized linearized plasmid as an internal control for real-time PCR. The assay results were correlated as the initial quantity (copies/μl) with fungal burden. These data indicate that combination of nested PCR and real-time PCR assay provides an attractive alternative for identification of T. marneffei DNA in whole blood samples of HIV-infected patients. © The Author 2015. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  8. Real-time three-dimensional optical coherence tomography image-guided core-needle biopsy system.

    PubMed

    Kuo, Wei-Cheng; Kim, Jongsik; Shemonski, Nathan D; Chaney, Eric J; Spillman, Darold R; Boppart, Stephen A

    2012-06-01

    Advances in optical imaging modalities, such as optical coherence tomography (OCT), enable us to observe tissue microstructure at high resolution and in real time. Currently, core-needle biopsies are guided by external imaging modalities such as ultrasound imaging and x-ray computed tomography (CT) for breast and lung masses, respectively. These image-guided procedures are frequently limited by spatial resolution when using ultrasound imaging, or by temporal resolution (rapid real-time feedback capabilities) when using x-ray CT. One feasible approach is to perform OCT within small gauge needles to optically image tissue microstructure. However, to date, no system or core-needle device has been developed that incorporates both three-dimensional OCT imaging and tissue biopsy within the same needle for true OCT-guided core-needle biopsy. We have developed and demonstrate an integrated core-needle biopsy system that utilizes catheter-based 3-D OCT for real-time image-guidance for target tissue localization, imaging of tissue immediately prior to physical biopsy, and subsequent OCT imaging of the biopsied specimen for immediate assessment at the point-of-care. OCT images of biopsied ex vivo tumor specimens acquired during core-needle placement are correlated with corresponding histology, and computational visualization of arbitrary planes within the 3-D OCT volumes enables feedback on specimen tissue type and biopsy quality. These results demonstrate the potential for using real-time 3-D OCT for needle biopsy guidance by imaging within the needle and tissue during biopsy procedures.

  9. Complex-valued time-series correlation increases sensitivity in FMRI analysis.

    PubMed

    Kociuba, Mary C; Rowe, Daniel B

    2016-07-01

    To develop a linear matrix representation of correlation between complex-valued (CV) time-series in the temporal Fourier frequency domain, and demonstrate its increased sensitivity over correlation between magnitude-only (MO) time-series in functional MRI (fMRI) analysis. The standard in fMRI is to discard the phase before the statistical analysis of the data, despite evidence of task related change in the phase time-series. With a real-valued isomorphism representation of Fourier reconstruction, correlation is computed in the temporal frequency domain with CV time-series data, rather than with the standard of MO data. A MATLAB simulation compares the Fisher-z transform of MO and CV correlations for varying degrees of task related magnitude and phase amplitude change in the time-series. The increased sensitivity of the complex-valued Fourier representation of correlation is also demonstrated with experimental human data. Since the correlation description in the temporal frequency domain is represented as a summation of second order temporal frequencies, the correlation is easily divided into experimentally relevant frequency bands for each voxel's temporal frequency spectrum. The MO and CV correlations for the experimental human data are analyzed for four voxels of interest (VOIs) to show the framework with high and low contrast-to-noise ratios in the motor cortex and the supplementary motor cortex. The simulation demonstrates the increased strength of CV correlations over MO correlations for low magnitude contrast-to-noise time-series. In the experimental human data, the MO correlation maps are noisier than the CV maps, and it is more difficult to distinguish the motor cortex in the MO correlation maps after spatial processing. Including both magnitude and phase in the spatial correlation computations more accurately defines the correlated left and right motor cortices. Sensitivity in correlation analysis is important to preserve the signal of interest in fMRI data sets with high noise variance, and avoid excessive processing induced correlation. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Soft sensor for monitoring biomass subpopulations in mammalian cell culture processes.

    PubMed

    Kroll, Paul; Stelzer, Ines V; Herwig, Christoph

    2017-11-01

    Biomass subpopulations in mammalian cell culture processes cause impurities and influence productivity, which requires this critical process parameter to be monitored in real-time. For this reason, a novel soft sensor concept for estimating viable, dead and lysed cell concentration was developed, based on the robust and cheap in situ measurements of permittivity and turbidity in combination with a simple model. It could be shown that the turbidity measurements contain information about all investigated biomass subpopulations. The novelty of the developed soft sensor is the real-time estimation of lysed cell concentration, which is directly correlated to process-related impurities such as DNA and host cell protein in the supernatant. Based on data generated by two fed-batch processes the developed soft sensor is described and discussed. The presented soft sensor concept provides a tool for viable, dead and lysed cell concentration estimation in real-time with adequate accuracy and enables further applications with respect to process optimization and control.

  11. A high sensitivity real-time NVR monitor. [Nonvolatile Residue

    NASA Technical Reports Server (NTRS)

    Bowers, William D.; Chuan, R. L.

    1992-01-01

    The use of a temperature-controlled 200-MHz SAW resonator piezoelectric mass microbalance to monitor the mass of nonvolatile residue (NVR) deposited on its surface in real time is reported. The fundamental frequency of this device is mainly dependent on the configuration of the transducers and not on the thickness of the substrate. Therefore, higher operating frequencies can be achieved without reducing the thickness of the crystal. The real-time instrument was integrated onto a conventional stainless steel NVR plate and operated flawlessly over a 14-d period at Kennedy Space Center and successfully measured less than 1 ng/sq cm d NVR contamination. Contamination episodes detected by the instrument were correlated with scheduled activities on the test stand. Under the assumption of a baseline noise level of +/- 2 Hz, the absolute mass lower limit of detection would be 0.065 ng/sq cm. This would enable the detection of a daily NVR deposition rate of less than 0.1 ng/sq cm d.

  12. Comparison of clinical application of the Abbott HBV PCR kit and the VERSANT HBV DNA 3.0 test to measure serum hepatitis B virus DNA in Taiwanese patients.

    PubMed

    Yang, Jeng-Fu; Lin, Ya-Yun; Huang, Jee-Fu; Liu, Shu-Fen; Chu, Pei-Yu; Hsieh, Ming-Yen; Lin, Zu-Yau; Chen, Shinn-Cherng; Wang, Liang-Yen; Dai, Chia-Yen; Chuang, Wan-Long; Yu, Ming-Lung

    2009-08-01

    With an estimated 350-400 million people worldwide chronically infected with hepatitis B virus (HBV), and the subsequent serious complications caused by liver damage including cirrhosis, liver failure, and hepatocellular carcinoma, HBV infection remains a global health issue, particularly in Taiwan, an HBV-hyperendemic area. Sensitive and accurate quantification of HBV DNA is necessary to monitor patients with chronic hepatitis B who are receiving antiviral therapy to determine treatment response and adapt therapy. We evaluated and compared the clinical performance of two HBV DNA assays based on different technologies: the RealArt HBV PCR Kit (Abbott HBV DNA PCR kit, real-time polymerase chain reaction assay, detection limit: 27 IU/mL) and the VERSANT bDNA 3.0 assay (Bayer, branched DNA signal amplification assay, detection limit: 357 IU/mL). Serum levels of HBV DNA in 173 chronic HBV carriers were determined using both the RealArt HBV PCR Kit and the VERSANT bDNA 3.0 test. Of the 173 samples analyzed for baseline viral load detection, HBV DNA was quantifiable in 147 patients (82.1%) by the RealArt HBV PCR Kit, which was significantly higher than the 92 (53.2%) samples quantified by the VERSANT bDNA 3.0 assay. A total of 86 (49.7%) samples were quantifiable by both assays, whereas 25 (14.5%) were below the detection limit of both assays. The HBV DNA quantification values measured by the RealArt HBV PCR Kit and the VERSANT bDNA 3.0 assay were positively correlated (Spearman's rank correlation coefficient r = 0.932, p < 0.001). On average, the results derived from the RealArt HBV PCR Kit were 0.67 log lower than those of the VERSANT bDNA 3.0 assay. HBV DNA concentrations were significantly higher in 63 HBV e antigen (HBeAg)-seropositive patients than in 110 HBeAg-seronegative patients (5.42 +/- 2.34 logs vs. 3.21 +/- 2.27 logs, p < 0.001). The RealArt HBV PCR Kit is more sensitive and has a wider dynamic range than the VERSANT bDNA 3.0 assay in the clinical setting of chronic hepatitis B patients. The sensitivity and wide dynamic range of the PCR assay allow optimal monitoring and timely adaptation of antiviral therapy. Nevertheless, the HBV DNA values measured by the RealArt HBV PCR Kit and the VERSANT bDNA 3.0 assay were significantly correlated.

  13. There Is No Correlation Between Erectile Dysfunction and Dose to Penile Bulb and Neurovascular Bundles Following Real-Time Low-Dose-Rate Prostate Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Solan, Amy N.; Cesaretti, Jamie A.; Stone, Nelson N.

    2009-04-01

    Purpose: We evaluated the relationship between the onset of erectile dysfunction and dose to the penile bulb and neurovascular bundles (NVBs) after real-time ultrasound-guided prostate brachytherapy. Methods and Materials: One hundred forty-seven patients who underwent prostate brachytherapy met the following eligibility criteria: (1) treatment with {sup 125}I brachytherapy to a prescribed dose of 160 Gy with or without hormones without supplemental external beam radiation therapy, (2) identification as potent before the time of implantation based on a score of 2 or higher on the physician-assigned Mount Sinai Erectile Function Score and a score of 16 or higher on the abbreviatedmore » International Index of Erectile Function patient assessment, and (3) minimum follow-up of 12 months. Median follow-up was 25.7 months (range, 12-47 months). Results: The 3-year actuarial rate of impotence was 23% (34 of 147 patients). An additional 43% of potent patients (49 of 113 patients) were using a potency aid at last follow-up. The penile bulb volume receiving 100% of the prescription dose (V{sub 100}) ranged from 0-0.05 cc (median, 0 cc), with a dose to the hottest 5% (D{sub 5}) range of 12.5-97.9 Gy (median, 40.8 Gy). There was no correlation between penile bulb D{sub 5} or V{sub 100} and postimplantation impotency on actuarial analysis. For the combined right and left NVB structures, V{sub 100} range was 0.3-5.1 cc (median, 1.8 cc), and V{sub 150} range was 0-1.5 cc (median, 0.31 cc). There was no association between NVB V{sub 100} or V{sub 150} and postimplantation impotency on actuarial analysis. Conclusion: Penile bulb doses are low after real-time ultrasound-guided prostate brachytherapy. We found no correlation between dose to either the penile bulb or NVBs and the development of postimplantation impotency.« less

  14. SU-E-J-66: Evaluation of a Real-Time Positioning Assistance Simulator System for Skull Radiography Using the Microsoft Kinect

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurata, T; Ono, M; Kozono, K

    2014-06-01

    Purpose: The purpose of this study is to investigate the feasibility of a low cost, small size positioning assistance simulator system for skull radiography using the Microsoft Kinect sensor. A conventional radiographic simulator system can only measure the three-dimensional coordinates of an x-ray tube using angle sensors, but not measure the movement of the subject. Therefore, in this study, we developed a real-time simulator system using the Microsoft Kinect to measure both the x-ray tube and the subject, and evaluated its accuracy and feasibility by comparing the simulated and the measured x-ray images. Methods: This system can track a headmore » phantom by using Face Tracking, which is one of the functions of the Kinect. The relative relationship between the Kinect and the head phantom was measured and the projection image was calculated by using the ray casting method, and by using three-dimensional CT head data with 220 slices at 512 × 512 pixels. X-ray images were thus obtained by using a computed radiography (CR) system. We could then compare the simulated projection images with the measured x-ray images from 0 degrees to 45 degrees at increments of 15 degrees by calculating the cross correlation coefficient C. Results: The calculation time of the simulated projection images was almost real-time (within 1 second) by using the Graphics Processing Unit(GPU). The cross-correlation coefficients C are: 0.916; 0.909; 0.891; and, 0.886 at 0, 15, 30, and 45 degrees, respectively. As a result, there were strong correlations between the simulated and measured images. Conclusion: This system can be used to perform head positioning more easily and accurately. It is expected that this system will be useful for learning radiographic techniques by students. Moreover, it could also be used for predicting the actual x-ray image prior to x-ray exposure in clinical environments.« less

  15. An interdimensional correlation framework for real-time estimation of six degree of freedom target motion using a single x-ray imager during radiotherapy

    NASA Astrophysics Data System (ADS)

    Nguyen, D. T.; Bertholet, J.; Kim, J.-H.; O'Brien, R.; Booth, J. T.; Poulsen, P. R.; Keall, P. J.

    2018-01-01

    Increasing evidence suggests that intrafraction tumour motion monitoring needs to include both 3D translations and 3D rotations. Presently, methods to estimate the rotation motion require the 3D translation of the target to be known first. However, ideally, translation and rotation should be estimated concurrently. We present the first method to directly estimate six-degree-of-freedom (6DoF) motion from the target’s projection on a single rotating x-ray imager in real-time. This novel method is based on the linear correlations between the superior-inferior translations and the motion in the other five degrees-of-freedom. The accuracy of the method was evaluated in silico with 81 liver tumour motion traces from 19 patients with three implanted markers. The ground-truth motion was estimated using the current gold standard method where each marker’s 3D position was first estimated using a Gaussian probability method, and the 6DoF motion was then estimated from the 3D positions using an iterative method. The 3D position of each marker was projected onto a gantry-mounted imager with an imaging rate of 11 Hz. After an initial 110° gantry rotation (200 images), a correlation model between the superior-inferior translations and the five other DoFs was built using a least square method. The correlation model was then updated after each subsequent frame to estimate 6DoF motion in real-time. The proposed algorithm had an accuracy (±precision) of  -0.03  ±  0.32 mm, -0.01  ±  0.13 mm and 0.03  ±  0.52 mm for translations in the left-right (LR), superior-inferior (SI) and anterior-posterior (AP) directions respectively; and, 0.07  ±  1.18°, 0.07  ±  1.00° and 0.06  ±  1.32° for rotations around the LR, SI and AP axes respectively on the dataset. The first method to directly estimate real-time 6DoF target motion from segmented marker positions on a 2D imager was devised. The algorithm was evaluated using 81 motion traces from 19 liver patients and was found to have sub-mm and sub-degree accuracy.

  16. HIV-1 viral load measurement in venous blood and fingerprick blood using Abbott RealTime HIV-1 DBS assay.

    PubMed

    Tang, Ning; Pahalawatta, Vihanga; Frank, Andrea; Bagley, Zowie; Viana, Raquel; Lampinen, John; Leckie, Gregor; Huang, Shihai; Abravaya, Klara; Wallis, Carole L

    2017-07-01

    HIV RNA suppression is a key indicator for monitoring success of antiretroviral therapy. From a logistical perspective, viral load (VL) testing using Dried Blood Spots (DBS) is a promising alternative to plasma based VL testing in resource-limited settings. To evaluate the analytical and clinical performance of the Abbott RealTime HIV-1 assay using a fully automated one-spot DBS sample protocol. Limit of detection (LOD), linearity, lower limit of quantitation (LLQ), upper limit of quantitation (ULQ), and precision were determined using serial dilutions of HIV-1 Virology Quality Assurance stock (VQA Rush University), or HIV-1-containing armored RNA, made in venous blood. To evaluate correlation, bias, and agreement, 497 HIV-1 positive adult clinical samples were collected from Ivory Coast, Uganda and South Africa. For each HIV-1 participant, DBS-fingerprick, DBS-venous and plasma sample results were compared. Correlation and bias values were obtained. The sensitivity and specificity were analyzed at a threshold of 1000 HIV-1 copies/mL generated using the standard plasma protocol. The Abbott HIV-1 DBS protocol had an LOD of 839 copies/mL, a linear range from 500 to 1×10 7 copies/mL, an LLQ of 839 copies/mL, a ULQ of 1×10 7 copies/mL, and an inter-assay SD of ≤0.30 log copies/mL for all tested levels within this range. With clinical samples, the correlation coefficient (r value) was 0.896 between DBS-fingerprick and plasma and 0.901 between DBS-venous and plasma, and the bias was -0.07 log copies/mL between DBS-fingerprick and plasma and -0.02 log copies/mL between DBS-venous and plasma. The sensitivity of DBS-fingerprick and DBS-venous was 93%, while the specificity of both DBS methods was 95%. The results demonstrated that the Abbott RealTime HIV-1 assay with DBS sample protocol is highly sensitive, specific and precise across a wide dynamic range and correlates well with plasma values. The Abbott RealTime HIV-1 assay with DBS sample protocol provides an alternative sample collection and transfer option in resource-limited settings and expands the utility of a viral load test to monitor HIV-1 ART treatment for infected patients. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.

  17. Identification of real-time diagnostic measures of visual distraction with an automatic eye-tracking system.

    PubMed

    Zhang, Harry; Smith, Matthew R H; Witt, Gerald J

    2006-01-01

    This study was conducted to identify eye glance measures that are diagnostic of visual distraction. Visual distraction degrades performance, but real-time diagnostic measures have not been identified. In a driving simulator, 14 participants responded to a lead vehicle braking at -2 or -2.7 m/s2 periodically while reading a varying number of words (6-15 words every 13 s) on peripheral displays (with diagonal eccentricities of 24 degrees, 43 degrees, and 75 degrees). As the number of words and display eccentricity increased, total glance duration and reaction time increased and driving performance suffered. Correlation coefficients between several glance measures and reaction time or performance variables were reliably high, indicating that these glance measures are diagnostic of visual distraction. It is predicted that for every 25% increase in total glance duration, reaction time is increased by 0.39 s and standard deviation of lane position is increased by 0.06 m. Potential applications of this research include assessing visual distraction in real time, delivering advisories to distracted drivers to reorient their attention to driving, and using distraction information to adapt forward collision and lane departure warning systems to enhance system effectiveness.

  18. Quantifying Differential Privacy under Temporal Correlations.

    PubMed

    Cao, Yang; Yoshikawa, Masatoshi; Xiao, Yonghui; Xiong, Li

    2017-04-01

    Differential Privacy (DP) has received increasing attention as a rigorous privacy framework. Many existing studies employ traditional DP mechanisms (e.g., the Laplace mechanism) as primitives, which assume that the data are independent, or that adversaries do not have knowledge of the data correlations. However, continuous generated data in the real world tend to be temporally correlated, and such correlations can be acquired by adversaries. In this paper, we investigate the potential privacy loss of a traditional DP mechanism under temporal correlations in the context of continuous data release. First, we model the temporal correlations using Markov model and analyze the privacy leakage of a DP mechanism when adversaries have knowledge of such temporal correlations. Our analysis reveals that the privacy loss of a DP mechanism may accumulate and increase over time . We call it temporal privacy leakage . Second, to measure such privacy loss, we design an efficient algorithm for calculating it in polynomial time. Although the temporal privacy leakage may increase over time, we also show that its supremum may exist in some cases. Third, to bound the privacy loss, we propose mechanisms that convert any existing DP mechanism into one against temporal privacy leakage. Experiments with synthetic data confirm that our approach is efficient and effective.

  19. Accurate estimation of influenza epidemics using Google search data via ARGO.

    PubMed

    Yang, Shihao; Santillana, Mauricio; Kou, S C

    2015-11-24

    Accurate real-time tracking of influenza outbreaks helps public health officials make timely and meaningful decisions that could save lives. We propose an influenza tracking model, ARGO (AutoRegression with GOogle search data), that uses publicly available online search data. In addition to having a rigorous statistical foundation, ARGO outperforms all previously available Google-search-based tracking models, including the latest version of Google Flu Trends, even though it uses only low-quality search data as input from publicly available Google Trends and Google Correlate websites. ARGO not only incorporates the seasonality in influenza epidemics but also captures changes in people's online search behavior over time. ARGO is also flexible, self-correcting, robust, and scalable, making it a potentially powerful tool that can be used for real-time tracking of other social events at multiple temporal and spatial resolutions.

  20. Note: a 4 ns hardware photon correlator based on a general-purpose field-programmable gate array development board implemented in a compact setup for fluorescence correlation spectroscopy.

    PubMed

    Kalinin, Stanislav; Kühnemuth, Ralf; Vardanyan, Hayk; Seidel, Claus A M

    2012-09-01

    We present a fast hardware photon correlator implemented in a field-programmable gate array (FPGA) combined with a compact confocal fluorescence setup. The correlator has two independent units with a time resolution of 4 ns while utilizing less than 15% of a low-end FPGA. The device directly accepts transistor-transistor logic (TTL) signals from two photon counting detectors and calculates two auto- or cross-correlation curves in real time. Test measurements demonstrate that the performance of our correlator is comparable with the current generation of commercial devices. The sensitivity of the optical setup is identical or even superior to current commercial devices. The FPGA design and the optical setup both allow for a straightforward extension to multi-color applications. This inexpensive and compact solution with a very good performance can serve as a versatile platform for uses in education, applied sciences, and basic research.

  1. Note: A 4 ns hardware photon correlator based on a general-purpose field-programmable gate array development board implemented in a compact setup for fluorescence correlation spectroscopy

    NASA Astrophysics Data System (ADS)

    Kalinin, Stanislav; Kühnemuth, Ralf; Vardanyan, Hayk; Seidel, Claus A. M.

    2012-09-01

    We present a fast hardware photon correlator implemented in a field-programmable gate array (FPGA) combined with a compact confocal fluorescence setup. The correlator has two independent units with a time resolution of 4 ns while utilizing less than 15% of a low-end FPGA. The device directly accepts transistor-transistor logic (TTL) signals from two photon counting detectors and calculates two auto- or cross-correlation curves in real time. Test measurements demonstrate that the performance of our correlator is comparable with the current generation of commercial devices. The sensitivity of the optical setup is identical or even superior to current commercial devices. The FPGA design and the optical setup both allow for a straightforward extension to multi-color applications. This inexpensive and compact solution with a very good performance can serve as a versatile platform for uses in education, applied sciences, and basic research.

  2. Lack of correlation between reaction speed and analytical sensitivity in isothermal amplification reveals the value of digital methods for optimization: validation using digital real-time RT-LAMP.

    PubMed

    Khorosheva, Eugenia M; Karymov, Mikhail A; Selck, David A; Ismagilov, Rustem F

    2016-01-29

    In this paper, we asked if it is possible to identify the best primers and reaction conditions based on improvements in reaction speed when optimizing isothermal reactions. We used digital single-molecule, real-time analyses of both speed and efficiency of isothermal amplification reactions, which revealed that improvements in the speed of isothermal amplification reactions did not always correlate with improvements in digital efficiency (the fraction of molecules that amplify) or with analytical sensitivity. However, we observed that the speeds of amplification for single-molecule (in a digital device) and multi-molecule (e.g. in a PCR well plate) formats always correlated for the same conditions. Also, digital efficiency correlated with the analytical sensitivity of the same reaction performed in a multi-molecule format. Our finding was supported experimentally with examples of primer design, the use or exclusion of loop primers in different combinations, and the use of different enzyme mixtures in one-step reverse-transcription loop-mediated amplification (RT-LAMP). Our results show that measuring the digital efficiency of amplification of single-template molecules allows quick, reliable comparisons of the analytical sensitivity of reactions under any two tested conditions, independent of the speeds of the isothermal amplification reactions. © The Author(s) 2015. Published by Oxford University Press on behalf of Nucleic Acids Research.

  3. Real-time PCR to determine transgene copy number and to quantitate the biolocalization of adoptively transferred cells from EGFP-transgenic mice.

    PubMed

    Joshi, Molishree; Keith Pittman, H; Haisch, Carl; Verbanac, Kathryn

    2008-09-01

    Quantitative real-time PCR (qPCR) is a sensitive technique for the detection and quantitation of specific DNA sequences. Here we describe a Taqman qPCR assay for quantification of tissue-localized, adoptively transferred enhanced green fluorescent protein (EGFP)-transgenic cells. A standard curve constructed from serial dilutions of a plasmid containing the EGFP transgene was (i) highly reproducible, (ii) detected as few as two copies, and (iii) was included in each qPCR assay. qPCR analysis of genomic DNA was used to determine transgene copy number in several mouse strains. Fluorescent microscopy of tissue sections showed that adoptively transferred vascular endothelial cells (VEC) from EGFP-transgenic mice specifically localized to tissue with metastatic tumors in syngeneic recipients. VEC microscopic enumeration of liver metastases strongly correlated with qPCR analysis of identical sections (Pearson correlation 0.81). EGFP was undetectable in tissue from control mice by qPCR. In another study using intra-tumor EGFP-VEC delivery to subcutaneous tumors, manual cell count and qPCR analysis of alternating sections also strongly correlated (Pearson correlation 0.82). Confocal microscopy of the subcutaneous tumor sections determined that visual fluorescent signals were frequently tissue artifacts. This qPCR methodology offers specific, objective, and rapid quantitation, uncomplicated by tissue autofluorescence, and should be readily transferable to other in vivo models to quantitate the biolocalization of transplanted cells.

  4. Improved real-time dynamics from imaginary frequency lattice simulations

    NASA Astrophysics Data System (ADS)

    Pawlowski, Jan M.; Rothkopf, Alexander

    2018-03-01

    The computation of real-time properties, such as transport coefficients or bound state spectra of strongly interacting quantum fields in thermal equilibrium is a pressing matter. Since the sign problem prevents a direct evaluation of these quantities, lattice data needs to be analytically continued from the Euclidean domain of the simulation to Minkowski time, in general an ill-posed inverse problem. Here we report on a novel approach to improve the determination of real-time information in the form of spectral functions by setting up a simulation prescription in imaginary frequencies. By carefully distinguishing between initial conditions and quantum dynamics one obtains access to correlation functions also outside the conventional Matsubara frequencies. In particular the range between ω0 and ω1 = 2πT, which is most relevant for the inverse problem may be more highly resolved. In combination with the fact that in imaginary frequencies the kernel of the inverse problem is not an exponential but only a rational function we observe significant improvements in the reconstruction of spectral functions, demonstrated in a simple 0+1 dimensional scalar field theory toy model.

  5. Forecast and Specification of Radiation Belt Electrons Based on Solar Wind Measurements

    NASA Astrophysics Data System (ADS)

    Li, X.; Barker, A.; Burin Des Roziers, E.

    2003-12-01

    Relativistic electrons in the Earth's magnetosphere are of considerable practical importance because of their effect on spacecraft and because of their radiation hazard to astronauts who perform extravehicular activity. The good correlation between solar wind velocity and MeV electron fluxes at geosynchronous orbit has long been established. We have developed a radial diffusion model, using solar wind parameters as the only input, to reproduce the variation of the MeV electrons at geosynchronous orbit. Based on this model, we have constructed a real-time model that forecasts one to two days in advance the daily averaged >2 MeV electron flux at geosynchronous orbit using real-time solar wind data from ACE. The forecasts from this model are available on the web in real time. A natural extension of our current model is to create a system for making quantitative forecasts and specifications of radiation belt electrons at different radial distances and different local times based on the solar wind conditions. The successes and obstacles associated with this extension will be discussed in this presentation.

  6. Sensing Cell-Culture Assays with Low-Cost Circuitry.

    PubMed

    Pérez, Pablo; Huertas, Gloria; Maldonado-Jacobi, Andrés; Martín, María; Serrano, Juan A; Olmo, Alberto; Daza, Paula; Yúfera, Alberto

    2018-06-11

    An alternative approach for cell-culture end-point protocols is proposed herein. This new technique is suitable for real-time remote sensing. It is based on Electrical Cell-substrate Impedance Spectroscopy (ECIS) and employs the Oscillation-Based Test (OBT) method. Simple and straightforward circuit blocks form the basis of the proposed measurement system. Oscillation parameters - frequency and amplitude - constitute the outcome, directly correlated with the culture status. A user can remotely track the evolution of cell cultures in real time over the complete experiment through a web tool continuously displaying the acquired data. Experiments carried out with commercial electrodes and a well-established cell line (AA8) are described, obtaining the cell number in real time from growth assays. The electrodes have been electrically characterized along the design flow in order to predict the system performance and the sensitivity curves. Curves for 1-week cell growth are reported. The obtained experimental results validate the proposed OBT for cell-culture characterization. Furthermore, the proposed electrode model provides a good approximation for the cell number and the time evolution of the studied cultures.

  7. Flow-induced corrosion of absorbable magnesium alloy: In-situ and real-time electrochemical study

    PubMed Central

    Wang, Juan; Jang, Yongseok; Wan, Guojiang; Giridharan, Venkataraman; Song, Guang-Ling; Xu, Zhigang; Koo, Youngmi; Qi, Pengkai; Sankar, Jagannathan; Huang, Nan; Yun, Yeoheung

    2016-01-01

    An in-situ and real-time electrochemical study in a vascular bioreactor was designed to analyze corrosion mechanism of magnesium alloy (MgZnCa) under mimetic hydrodynamic conditions. Effect of hydrodynamics on corrosion kinetics, types, rates and products was analyzed. Flow-induced shear stress (FISS) accelerated mass and electron transfer, leading to an increase in uniform and localized corrosions. FISS increased the thickness of uniform corrosion layer, but filiform corrosion decreased this layer resistance at high FISS conditions. FISS also increased the removal rate of localized corrosion products. Impedance-estimated and linear polarization-measured polarization resistances provided a consistent correlation to corrosion rate calculated by computed tomography. PMID:28626241

  8. Flow-induced corrosion of absorbable magnesium alloy: In-situ and real-time electrochemical study.

    PubMed

    Wang, Juan; Jang, Yongseok; Wan, Guojiang; Giridharan, Venkataraman; Song, Guang-Ling; Xu, Zhigang; Koo, Youngmi; Qi, Pengkai; Sankar, Jagannathan; Huang, Nan; Yun, Yeoheung

    2016-03-01

    An in-situ and real-time electrochemical study in a vascular bioreactor was designed to analyze corrosion mechanism of magnesium alloy (MgZnCa) under mimetic hydrodynamic conditions. Effect of hydrodynamics on corrosion kinetics, types, rates and products was analyzed. Flow-induced shear stress (FISS) accelerated mass and electron transfer, leading to an increase in uniform and localized corrosions. FISS increased the thickness of uniform corrosion layer, but filiform corrosion decreased this layer resistance at high FISS conditions. FISS also increased the removal rate of localized corrosion products. Impedance-estimated and linear polarization-measured polarization resistances provided a consistent correlation to corrosion rate calculated by computed tomography.

  9. Real-Time Maps of Fluid Flow Fields in Porous Biomaterials

    PubMed Central

    Mack, Julia J.; Youssef, Khalid; Noel, Onika D.V.; Lake, Michael P.; Wu, Ashley; Iruela-Arispe, M. Luisa; Bouchard, Louis-S.

    2013-01-01

    Mechanical forces such as fluid shear have been shown to enhance cell growth and differentiation, but knowledge of their mechanistic effect on cells is limited because the local flow patterns and associated metrics are not precisely known. Here we present real-time, noninvasive measures of local hydrodynamics in 3D biomaterials based on nuclear magnetic resonance. Microflow maps were further used to derive pressure, shear and fluid permeability fields. Finally, remodeling of collagen gels in response to precise fluid flow parameters was correlated with structural changes. It is anticipated that accurate flow maps within 3D matrices will be a critical step towards understanding cell behavior in response to controlled flow dynamics. PMID:23245922

  10. Magnitude and sign of long-range correlated time series: Decomposition and surrogate signal generation.

    PubMed

    Gómez-Extremera, Manuel; Carpena, Pedro; Ivanov, Plamen Ch; Bernaola-Galván, Pedro A

    2016-04-01

    We systematically study the scaling properties of the magnitude and sign of the fluctuations in correlated time series, which is a simple and useful approach to distinguish between systems with different dynamical properties but the same linear correlations. First, we decompose artificial long-range power-law linearly correlated time series into magnitude and sign series derived from the consecutive increments in the original series, and we study their correlation properties. We find analytical expressions for the correlation exponent of the sign series as a function of the exponent of the original series. Such expressions are necessary for modeling surrogate time series with desired scaling properties. Next, we study linear and nonlinear correlation properties of series composed as products of independent magnitude and sign series. These surrogate series can be considered as a zero-order approximation to the analysis of the coupling of magnitude and sign in real data, a problem still open in many fields. We find analytical results for the scaling behavior of the composed series as a function of the correlation exponents of the magnitude and sign series used in the composition, and we determine the ranges of magnitude and sign correlation exponents leading to either single scaling or to crossover behaviors. Finally, we obtain how the linear and nonlinear properties of the composed series depend on the correlation exponents of their magnitude and sign series. Based on this information we propose a method to generate surrogate series with controlled correlation exponent and multifractal spectrum.

  11. Real-time acquisition and preprocessing system of transient electromagnetic data based on LabVIEW

    NASA Astrophysics Data System (ADS)

    Zhao, Huinan; Zhang, Shuang; Gu, Lingjia; Sun, Jian

    2014-09-01

    Transient electromagnetic method (TEM) is regarded as an everlasting issue for geological exploration. It is widely used in many research fields, such as mineral exploration, hydrogeology survey, engineering exploration and unexploded ordnance detection. The traditional measurement systems are often based on ARM DSP or FPGA, which have not real-time display, data preprocessing and data playback functions. In order to overcome the defects, a real-time data acquisition and preprocessing system based on LabVIEW virtual instrument development platform is proposed in the paper, moreover, a calibration model is established for TEM system based on a conductivity loop. The test results demonstrated that the system can complete real-time data acquisition and system calibration. For Transmit-Loop-Receive (TLR) response, the correlation coefficient between the measured results and the calculated results is 0.987. The measured results are basically consistent with the calculated results. Through the late inversion process for TLR, the signal of underground conductor was obtained. In the complex test environment, abnormal values usually exist in the measured data. In order to solve this problem, the judgment and revision algorithm of abnormal values is proposed in the paper. The test results proved that the proposed algorithm can effectively eliminate serious disturbance signals from the measured transient electromagnetic data.

  12. Quantitative analysis of diet structure by real-time PCR, reveals different feeding patterns by two dominant grasshopper species

    PubMed Central

    Huang, Xunbing; Wu, Huihui; McNeill, Mark Richard; Qin, Xinghu; Ma, Jingchuan; Tu, Xiongbing; Cao, Guangchun; Wang, Guangjun; Nong, Xiangqun; Zhang, Zehua

    2016-01-01

    Studies on grasshopper diets have historically employed a range of methodologies, each with certain advantages and disadvantages. For example, some methodologies are qualitative instead of quantitative. Others require long experimental periods or examine population-level effects, only. In this study, we used real-time PCR to examine diets of individual grasshoppers. The method has the advantage of being both fast and quantitative. Using two grasshopper species, Oedaleus asiaticus and Dasyhippus barbipes, we designed ITS primer sequences for their three main host plants, Stipa krylovii, Leymus chinensis and Cleistogenes squarrosa and used real-time PCR method to test diet structure both qualitatively and quantitatively. The lowest detection efficiency of the three grass species was ~80% with a strong correlation between actual and PCR-measured food intake. We found that Oedaleus asiaticus maintained an unchanged diet structure across grasslands with different grass communities. By comparison, Dasyhippus barbipes changed its diet structure. These results revealed why O. asiaticus distribution is mainly confined to Stipa-dominated grassland, and D. barbipes is more widely distributed across Inner Mongolia. Overall, real-time PCR was shown to be a useful tool for investigating grasshopper diets, which in turn offers some insight into grasshopper distributions and improved pest management. PMID:27562455

  13. Field transients of coherent terahertz synchrotron radiation accessed via time-resolving and correlation techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pohl, A.; Hübers, H.-W.; Institute of Optical Sensor Systems, German Aerospace Center

    2016-03-21

    Decaying oscillations of the electric field in repetitive pulses of coherent synchrotron radiation in the terahertz frequency range was evaluated by means of time-resolving and correlation techniques. Comparative analysis of real-time voltage transients of the electrical response and interferograms, which were obtained with an ultrafast zero-bias Schottky diode detector and a Martin-Puplett interferometer, delivers close values of the pulse duration. Consistent results were obtained via the correlation technique with a pair of Golay Cell detectors and a pair of resonant polarisation-sensitive superconducting detectors integrated on one chip. The duration of terahertz synchrotron pulses does not closely correlate with the durationmore » of single-cycle electric field expected for the varying size of electron bunches. We largely attribute the difference to the charge density oscillations in electron bunches and to the low-frequency spectral cut-off imposed by both the synchrotron beamline and the coupling optics of our detectors.« less

  14. Prediction of lamb carcass composition by impedance spectroscopy.

    PubMed

    Altmann, M; Pliquett, U; Suess, R; von Borell, E

    2004-03-01

    The objective of this study was to compare impedance spectroscopy with resistance measurements at a single frequency (50 kHz) for the prediction of lamb carcass composition. The impedance spectrum is usually recorded by measuring the complex impedance at various frequencies (frequency domain); however, in this study, we also applied the faster and simpler measurement in the time domain (application of a current step and measurement of the voltage response). The study was carried out on 24 male, German Black-headed Mutton lambs with an average BW of 45 kg. Frequency- and time domain-based impedance measurements were collected at 20 min and 24 h postmortem with different electrode placements. Real and imaginary parts at various frequencies were calculated from the locus diagram. Left sides were dissected into lean, fat, and bone, and right sides were ground to determine actual carcass composition. Crude fat, crude protein, and moisture were chemically analyzed on ground samples. Frequency- and time domain-based measurements did not provide the same absolute impedance values; however, the high correlations (P < 0.001) between these methods for the "real parts" showed that they ranked individuals in the same order. Most of the time domain data correlated higher to carcass composition than did the frequency domain data. The real parts of impedance showed correlations between -0.37 (P > 0.05) and -0.74 (P < 0.001) to water, crude fat, lean, and fatty tissue, whereas the relations to CP were much lower (from 0.00 to -0.47, P < 0.05). Electrode placements at different locations did not substantially improve the correlations with carcass composition. The "imaginary parts" of impedance were not suitable for the prediction of carcass composition. The highest accuracy (R2 = 0.66) was reached for the estimation of crude fat percentage by a regression equation with the time domain-based impedance measured at 24 h postmortem. Furthermore, there was not a clear superiority of measurements in a wide frequency range over a single frequency measurement at 50 kHz for the prediction of carcass composition. Even though we calculated the impedance at 50 kHz based on the locus diagram, which allowed for a high precision for predicting this impedance trait, single-frequency impedance devices typically used in practice cannot record the locus diagram and, therefore, exhibit a greater amount of uncertainty.

  15. Portable, real-time alloy identification of metallic wear debris from machinery lubrication systems: laser-induced breakdown spectroscopy versus x-ray fluorescence

    NASA Astrophysics Data System (ADS)

    Suresh, Pooja

    2014-05-01

    Alloy identification of oil-borne wear debris captured on chip detectors, filters and magnetic plugs allows the machinery maintainer to assess the health of the engine or gearbox and identify specific component damage. Today, such identification can be achieved in real time using portable, at-line laser-induced breakdown spectroscopy (LIBS) and Xray fluorescence (XRF) instruments. Both techniques can be utilized in various industries including aviation, marine, railways, heavy diesel and other industrial machinery with, however, some substantial differences in application and instrument performance. In this work, the performances of a LIBS and an XRF instrument are compared based on measurements of a wide range of typical aerospace alloys including steels, titanium, aluminum and nickel alloys. Measurement results were analyzed with a staged correlation technique specifically developed for the purposes of this study - identifying the particle alloy composition using a pre-recorded library of spectral signatures. The analysis is performed in two stages: first, the base element of the alloy is determined by correlation with the stored elemental spectra and then, the alloy is identified by matching the particle's spectral signature using parametric correlation against the stored spectra of all alloys that have the same base element. The correlation analysis has achieved highly repeatable discrimination between alloys of similar composition. Portable LIBS demonstrates higher detection accuracy and better identification of alloys comprising lighter elements as compared to that of the portable XRF system, and reveals a significant reduction in the analysis time over XRF.

  16. Identifying Optimal Temporal Scale for the Correlation of AOD and Ground Measurements of PM2.5 to Improve the Model Performance in a Real-time Air Quality Estimation System

    NASA Technical Reports Server (NTRS)

    Li, Hui; Faruque, Fazlay; Williams, Worth; Al-Hamdan, Mohammad; Luvall, Jeffrey C.; Crosson, William; Rickman, Douglas; Limaye, Ashutosh

    2009-01-01

    Aerosol optical depth (AOD), an indirect estimate of particle matter using satellite observations, has shown great promise in improving estimates of PM 2.5 air quality surface. Currently, few studies have been conducted to explore the optimal way to apply AOD data to improve the model accuracy of PM 2.5 surface estimation in a real-time air quality system. We believe that two major aspects may be worthy of consideration in that area: 1) the approach to integrate satellite measurements with ground measurements in the pollution estimation, and 2) identification of an optimal temporal scale to calculate the correlation of AOD and ground measurements. This paper is focused on the second aspect on the identifying the optimal temporal scale to correlate AOD with PM2.5. Five following different temporal scales were chosen to evaluate their impact on the model performance: 1) within the last 3 days, 2) within the last 10 days, 3) within the last 30 days, 4) within the last 90 days, and 5) the time period with the highest correlation in a year. The model performance is evaluated for its accuracy, bias, and errors based on the following selected statistics: the Mean Bias, the Normalized Mean Bias, the Root Mean Square Error, Normalized Mean Error, and the Index of Agreement. This research shows that the model with the temporal scale of within the last 30 days displays the best model performance in this study area using 2004 and 2005 data sets.

  17. Beating the limits with initial correlations

    NASA Astrophysics Data System (ADS)

    Basilewitsch, Daniel; Schmidt, Rebecca; Sugny, Dominique; Maniscalco, Sabrina; Koch, Christiane P.

    2017-11-01

    Fast and reliable reset of a qubit is a key prerequisite for any quantum technology. For real world open quantum systems undergoing non-Markovian dynamics, reset implies not only purification, but in particular erasure of initial correlations between qubit and environment. Here, we derive optimal reset protocols using a combination of geometric and numerical control theory. For factorizing initial states, we find a lower limit for the entropy reduction of the qubit as well as a speed limit. The time-optimal solution is determined by the maximum coupling strength. Initial correlations, remarkably, allow for faster reset and smaller errors. Entanglement is not necessary.

  18. Optical stereo video signal processor

    NASA Technical Reports Server (NTRS)

    Craig, G. D. (Inventor)

    1985-01-01

    An otpical video signal processor is described which produces a two-dimensional cross-correlation in real time of images received by a stereo camera system. The optical image of each camera is projected on respective liquid crystal light valves. The images on the liquid crystal valves modulate light produced by an extended light source. This modulated light output becomes the two-dimensional cross-correlation when focused onto a video detector and is a function of the range of a target with respect to the stereo camera. Alternate embodiments utilize the two-dimensional cross-correlation to determine target movement and target identification.

  19. Parallel algorithm of VLBI software correlator under multiprocessor environment

    NASA Astrophysics Data System (ADS)

    Zheng, Weimin; Zhang, Dong

    2007-11-01

    The correlator is the key signal processing equipment of a Very Lone Baseline Interferometry (VLBI) synthetic aperture telescope. It receives the mass data collected by the VLBI observatories and produces the visibility function of the target, which can be used to spacecraft position, baseline length measurement, synthesis imaging, and other scientific applications. VLBI data correlation is a task of data intensive and computation intensive. This paper presents the algorithms of two parallel software correlators under multiprocessor environments. A near real-time correlator for spacecraft tracking adopts the pipelining and thread-parallel technology, and runs on the SMP (Symmetric Multiple Processor) servers. Another high speed prototype correlator using the mixed Pthreads and MPI (Massage Passing Interface) parallel algorithm is realized on a small Beowulf cluster platform. Both correlators have the characteristic of flexible structure, scalability, and with 10-station data correlating abilities.

  20. System and Method for Finite Element Simulation of Helicopter Turbulence

    NASA Technical Reports Server (NTRS)

    McFarland, R. E. (Inventor); Dulsenberg, Ken (Inventor)

    1999-01-01

    The present invention provides a turbulence model that has been developed for blade-element helicopter simulation. This model uses an innovative temporal and geometrical distribution algorithm that preserves the statistical characteristics of the turbulence spectra over the rotor disc, while providing velocity components in real time to each of five blade-element stations along each of four blades. for a total of twenty blade-element stations. The simulator system includes a software implementation of flight dynamics that adheres to the guidelines for turbulence set forth in military specifications. One of the features of the present simulator system is that it applies simulated turbulence to the rotor blades of the helicopter, rather than to its center of gravity. The simulator system accurately models the rotor penetration into a gust field. It includes time correlation between the front and rear of the main rotor, as well as between the side forces felt at the center of gravity and at the tail rotor. It also includes features for added realism, such as patchy turbulence and vertical gusts in to which the rotor disc penetrates. These features are realized by a unique real time implementation of the turbulence filters. The new simulator system uses two arrays one on either side of the main rotor to record the turbulence field and to produce time-correlation from the front to the rear of the rotor disc. The use of Gaussian Interpolation between the two arrays maintains the statistical properties of the turbulence across the rotor disc. The present simulator system and method may be used in future and existing real-time helicopter simulations with minimal increase in computational workload.

  1. Testing for the Presence of Correlation Changes in a Multivariate Time Series: A Permutation Based Approach.

    PubMed

    Cabrieto, Jedelyn; Tuerlinckx, Francis; Kuppens, Peter; Hunyadi, Borbála; Ceulemans, Eva

    2018-01-15

    Detecting abrupt correlation changes in multivariate time series is crucial in many application fields such as signal processing, functional neuroimaging, climate studies, and financial analysis. To detect such changes, several promising correlation change tests exist, but they may suffer from severe loss of power when there is actually more than one change point underlying the data. To deal with this drawback, we propose a permutation based significance test for Kernel Change Point (KCP) detection on the running correlations. Given a requested number of change points K, KCP divides the time series into K + 1 phases by minimizing the within-phase variance. The new permutation test looks at how the average within-phase variance decreases when K increases and compares this to the results for permuted data. The results of an extensive simulation study and applications to several real data sets show that, depending on the setting, the new test performs either at par or better than the state-of-the art significance tests for detecting the presence of correlation changes, implying that its use can be generally recommended.

  2. Real-time imaging as an emerging process analytical technology tool for monitoring of fluid bed coating process.

    PubMed

    Naidu, Venkata Ramana; Deshpande, Rucha S; Syed, Moinuddin R; Wakte, Pravin S

    2018-07-01

    A direct imaging system (Eyecon TM ) was used as a Process Analytical Technology (PAT) tool to monitor fluid bed coating process. Eyecon TM generated real-time onscreen images, particle size and shape information of two identically manufactured laboratory-scale batches. Eyecon TM has accuracy of measuring the particle size increase of ±1 μm on particles in the size range of 50-3000 μm. Eyecon TM captured data every 2 s during the entire process. The moving average of D90 particle size values recorded by Eyecon TM were calculated for every 30 min to calculate the radial coating thickness of coated particles. After the completion of coating process, the radial coating thickness was found to be 11.3 and 9.11 μm, with a standard deviation of ±0.68 and 1.8 μm for Batch 1 and Batch 2, respectively. The coating thickness was also correlated with percent weight build-up by gel permeation chromatography (GPC) and dissolution. GPC indicated weight build-up of 10.6% and 9.27% for Batch 1 and Batch 2, respectively. In conclusion, weight build-up of 10% can also be correlated with 10 ± 2 μm increase in the coating thickness of pellets, indicating the potential applicability of real-time imaging as an endpoint determination tool for fluid bed coating process.

  3. Reorganization of functional brain networks mediates the improvement of cognitive performance following real-time neurofeedback training of working memory.

    PubMed

    Zhang, Gaoyan; Yao, Li; Shen, Jiahui; Yang, Yihong; Zhao, Xiaojie

    2015-05-01

    Working memory (WM) is essential for individuals' cognitive functions. Neuroimaging studies indicated that WM fundamentally relied on a frontoparietal working memory network (WMN) and a cinguloparietal default mode network (DMN). Behavioral training studies demonstrated that the two networks can be modulated by WM training. Different from the behavioral training, our recent study used a real-time functional MRI (rtfMRI)-based neurofeedback method to conduct WM training, demonstrating that WM performance can be significantly improved after successfully upregulating the activity of the target region of interest (ROI) in the left dorsolateral prefrontal cortex (Zhang et al., [2013]: PloS One 8:e73735); however, the neural substrate of rtfMRI-based WM training remains unclear. In this work, we assessed the intranetwork and internetwork connectivity changes of WMN and DMN during the training, and their correlations with the change of brain activity in the target ROI as well as with the improvement of post-training behavior. Our analysis revealed an "ROI-network-behavior" correlation relationship underlying the rtfMRI training. Further mediation analysis indicated that the reorganization of functional brain networks mediated the effect of self-regulation of the target brain activity on the improvement of cognitive performance following the neurofeedback training. The results of this study enhance our understanding of the neural basis of real-time neurofeedback and suggest a new direction to improve WM performance by regulating the functional connectivity in the WM related networks. © 2014 Wiley Periodicals, Inc.

  4. Real-time evaluation of diffusion of the local anesthetic solution during peribulbar block using ultrasound imaging and clinical correlates of diffusion.

    PubMed

    Luyet, Cédric; Eng, Kenneth T; Kertes, Peter J; Avila, Arsenio; Muni, Rajeev H; McHardy, Paul

    2012-01-01

    The aims of this prospective observational study were to assess the incidence of intraconal spread during peribulbar (extraconal) anesthesia by real-time ultrasound imaging of the retro-orbital compartment and to determine whether a complete sensory and motor block (with akinesia) of the eye is directly related to the intraconal spread. Ultrasound imaging was performed in 100 patients who underwent a surgical procedure on the posterior segment of the eye. All patients received a peribulbar block using the inferolateral approach. Once the needle was in place, a linear ultrasound transducer was placed over the eyelid and the spread of local anesthetics was assessed during the injection (real time). Akinesia was assessed by a blinded observer 10 minutes after block placement. The incidence of intraconal spread and its correlation with a complete akinesia was measured. The overall block failure rate was 28% in terms of akinesia, and the rate of rescue blocks was 20%. Clear intraconal spread during injection of the local anesthetic mixture could be detected with ultrasound imaging in 61 of 100 patients. The positive predictive value for successful block when intraconal spread was detected was 98% (95% confidence interval, 91%-100%). The association between clear and no evidence of intraconal spread and effective block was statistically significant (χ test, P < 0.001). Ultrasound imaging provides information of local anesthetic spread within the retro-orbital space, which might assist in the prediction of block success.

  5. Accelerated in vitro release testing method for naltrexone loaded PLGA microspheres.

    PubMed

    Andhariya, Janki V; Choi, Stephanie; Wang, Yan; Zou, Yuan; Burgess, Diane J; Shen, Jie

    2017-03-30

    The objective of the present study was to develop a discriminatory and reproducible accelerated release testing method for naltrexone loaded parenteral polymeric microspheres. The commercially available naltrexone microsphere product (Vivitrol ® ) was used as the testing formulation in the in vitro release method development, and both sample-and-separate and USP apparatus 4 methods were investigated. Following an in vitro drug stability study, frequent media replacement and addition of anti-oxidant in the release medium were used to prevent degradation of naltrexone during release testing at "real-time" (37°C) and "accelerated" (45°C), respectively. The USP apparatus 4 method was more reproducible than the sample-and-separate method. In addition, the accelerated release profile obtained using USP apparatus 4 had a shortened release duration (within seven days), and good correlation with the "real-time" release profile. Lastly, the discriminatory ability of the developed accelerated release method was assessed using compositionally equivalent naltrexone microspheres with different release characteristics. The developed accelerated USP apparatus 4 release method was able to detect differences in the release characteristics of the prepared naltrexone microspheres. Moreover, a linear correlation was observed between the "real-time" and accelerated release profiles of all the formulations investigated, suggesting that the release mechanism(s) may be similar under both conditions. These results indicate that the developed accelerated USP apparatus 4 method has the potential to be an appropriate fast quality control tool for long-acting naltrexone PLGA microspheres. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Targeted resequencing reveals ALK fusions in non-small cell lung carcinomas detected by FISH, immunohistochemistry, and real-time RT-PCR: a comparison of four methods.

    PubMed

    Tuononen, Katja; Sarhadi, Virinder Kaur; Wirtanen, Aino; Rönty, Mikko; Salmenkivi, Kaisa; Knuuttila, Aija; Remes, Satu; Telaranta-Keerie, Aino I; Bloor, Stuart; Ellonen, Pekka; Knuutila, Sakari

    2013-01-01

    Anaplastic lymphoma receptor tyrosine kinase (ALK) gene rearrangements occur in a subgroup of non-small cell lung carcinomas (NSCLCs). The identification of these rearrangements is important for guiding treatment decisions. The aim of our study was to screen ALK gene fusions in NSCLCs and to compare the results detected by targeted resequencing with results detected by commonly used methods, including fluorescence in situ hybridization (FISH), immunohistochemistry (IHC), and real-time reverse transcription-PCR (RT-PCR). Furthermore, we aimed to ascertain the potential of targeted resequencing in detection of ALK-rearranged lung carcinomas. We assessed ALK fusion status for 95 formalin-fixed paraffin-embedded tumor tissue specimens from 87 patients with NSCLC by FISH and real-time RT-PCR, for 57 specimens from 56 patients by targeted resequencing, and for 14 specimens from 14 patients by IHC. All methods were performed successfully on formalin-fixed paraffin-embedded tumor tissue material. We detected ALK fusion in 5.7% (5 out of 87) of patients examined. The results obtained from resequencing correlated significantly with those from FISH, real-time RT-PCR, and IHC. Targeted resequencing proved to be a promising method for ALK gene fusion detection in NSCLC. Means to reduce the material and turnaround time required for analysis are, however, needed.

  7. Latency Determination and Compensation in Real-Time Gnss/ins Integrated Navigation Systems

    NASA Astrophysics Data System (ADS)

    Solomon, P. D.; Wang, J.; Rizos, C.

    2011-09-01

    Unmanned Aerial Vehicle (UAV) technology is now commonplace in many defence and civilian environments. However, the high cost of owning and operating a sophisticated UAV has slowed their adoption in many commercial markets. Universities and research groups are actively experimenting with UAVs to further develop the technology, particularly for automated flying operations. The two main UAV platforms used are fixed-wing and helicopter. Helicopter-based UAVs offer many attractive features over fixed-wing UAVs, including vertical take-off, the ability to loiter, and highly dynamic flight. However the control and navigation of helicopters are significantly more demanding than those of fixed-wing UAVs and as such require a high bandwidth real-time Position, Velocity, Attitude (PVA) navigation system. In practical Real-Time Navigation Systems (RTNS) there are delays in the processing of the GNSS data prior to the fusion of the GNSS data with the INS measurements. This latency must be compensated for otherwise it degrades the solution of the navigation filter. This paper investigates the effect of latency in the arrival time of the GNSS data in a RTNS. Several test drives and flights were conducted with a low-cost RTNS, and compared with a high quality GNSS/INS solution. A technique for the real-time, automated and accurate estimation of the GNSS latency in low-cost systems was developed and tested. The latency estimates were then verified through cross-correlation with the time-stamped measurements from the reference system. A delayed measurement Extended Kalman Filter was then used to allow for the real-time fusing of the delayed measurements, and then a final system developed for on-the-fly measurement and compensation of GNSS latency in a RTNS.

  8. Performance on a computerized shopping task significantly predicts real world functioning in persons diagnosed with bipolar disorder.

    PubMed

    Laloyaux, Julien; Pellegrini, Nadia; Mourad, Haitham; Bertrand, Hervé; Domken, Marc-André; Van der Linden, Martial; Larøi, Frank

    2013-12-15

    Persons diagnosed with bipolar disorder often suffer from cognitive impairments. However, little is known concerning how these cognitive deficits impact their real world functioning. We developed a computerized real-life activity task, where participants are required to shop for a list of grocery store items. Twenty one individuals diagnosed with bipolar disorder and 21 matched healthy controls were administered the computerized shopping task. Moreover, the patient group was assessed with a battery of cognitive tests and clinical scales. Performance on the shopping task significantly differentiated patients and healthy controls for two variables: Total time to complete the shopping task and Mean time spent to consult the shopping list. Moreover, in the patient group, performance on these variables from the shopping task correlated significantly with cognitive functioning (i.e. processing speed, verbal episodic memory, planning, cognitive flexibility, and inhibition) and with clinical variables including duration of illness and real world functioning. Finally, variables from the shopping task were found to significantly explain 41% of real world functioning of patients diagnosed with bipolar disorder. These findings suggest that the shopping task provides a good indication of real world functioning and cognitive functioning of persons diagnosed with bipolar disorder. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  9. Measurement and correlation of acoustic cavitation with cellular bioeffects.

    PubMed

    Hallow, Daniel M; Mahajan, Anuj D; McCutchen, Todd E; Prausnitz, Mark R

    2006-07-01

    Using broadband noise as a measure of cavitation activity, this study determined the kinetics of cavitation during sonication of Optison contrast agent and tested whether cellular bioeffects can be predicted by cavitation dose. Cell suspensions were exposed to ultrasound at varying acoustic frequency, pressure, exposure time, Optison concentration and cell type to obtain a broad range of bioeffects, i.e., intracellular uptake and loss of viability, as quantified by flow cytometry. We found that cavitation activity measured by broadband noise increased and peaked within 20 ms and then decayed with a half-life of tens to hundreds of milliseconds. Intracellular uptake and loss of viability correlated well with the cavitation dose determined by the time integral of broadband noise magnitude. These results demonstrate that broadband noise correlates with bioeffects over a broad range of experimental conditions, which suggests a noninvasive feedback method to control ultrasound's bioeffects in real time.

  10. Application of speckle dynamics for studying metabolic activity of cell cultures with herpes virus

    NASA Astrophysics Data System (ADS)

    Vladimirov, A. P.; Bakharev, A. A.; Malygin, A. S.; Mikhaylova, J. A.; Borodin, E. M.; Poryvayeva, A. P.; Glinskikh, N. P.

    2014-05-01

    The report considers the results of the experiments in which digital values of light intensity I and the image area correlation index η values were recorded on a real-time basis for one or two days. Three cell cultures with viruses along with intact cultures were investigated. High correlation of dependence of η values on time t values was demonstrated for three cultures. The η=η(t) and I=I(t) dependences for cells with and without viruses differ considerably. It was shown that the presence of viruses could be determined as early as ten minutes after measurements were started.

  11. Wind energy system time-domain (WEST) analyzers

    NASA Technical Reports Server (NTRS)

    Dreier, M. E.; Hoffman, J. A.

    1981-01-01

    A portable analyzer which simulates in real time the complex nonlinear dynamics of horizontal axis wind energy systems was constructed. Math models for an aeroelastic rotor featuring nonlinear aerodynamic and inertial terms were implemented with high speed digital controllers and analog calculation. This model was combined with other math models of elastic supports, control systems, a power train and gimballed rotor kinematics. A stroboscopic display system graphically depicting distributed blade loads, motion, and other aerodynamic functions on a cathode ray tube is included. Limited correlation efforts showed good comparison between the results of this analyzer and other sophisticated digital simulations. The digital simulation results were successfully correlated with test data.

  12. An investigation of correlation between pilot scanning behavior and workload using stepwise regression analysis

    NASA Technical Reports Server (NTRS)

    Waller, M. C.

    1976-01-01

    An electro-optical device called an oculometer which tracks a subject's lookpoint as a time function has been used to collect data in a real-time simulation study of instrument landing system (ILS) approaches. The data describing the scanning behavior of a pilot during the instrument approaches have been analyzed by use of a stepwise regression analysis technique. A statistically significant correlation between pilot workload, as indicated by pilot ratings, and scanning behavior has been established. In addition, it was demonstrated that parameters derived from the scanning behavior data can be combined in a mathematical equation to provide a good representation of pilot workload.

  13. Demonstration of quantum synchronization based on second-order quantum coherence of entangled photons

    PubMed Central

    Quan, Runai; Zhai, Yiwei; Wang, Mengmeng; Hou, Feiyan; Wang, Shaofeng; Xiang, Xiao; Liu, Tao; Zhang, Shougang; Dong, Ruifang

    2016-01-01

    Based on the second-order quantum interference between frequency entangled photons that are generated by parametric down conversion, a quantum strategic algorithm for synchronizing two spatially separated clocks has been recently presented. In the reference frame of a Hong-Ou-Mandel (HOM) interferometer, photon correlations are used to define simultaneous events. Once the HOM interferometer is balanced by use of an adjustable optical delay in one arm, arrival times of simulta- neously generated photons are recorded by each clock. The clock offset is determined by correlation measurement of the recorded arrival times. Utilizing this algorithm, we demonstrate a proof-of-principle experiment for synchronizing two clocks separated by 4 km fiber link. A minimum timing stability of 0.44 ps at averaging time of 16000 s is achieved with an absolute time accuracy of 73.2 ps. The timing stability is verified to be limited by the correlation measurement device and ideally can be better than 10 fs. Such results shine a light to the application of quantum clock synchronization in the real high-accuracy timing system. PMID:27452276

  14. Theory of Financial Risk and Derivative Pricing

    NASA Astrophysics Data System (ADS)

    Bouchaud, Jean-Philippe; Potters, Marc

    2009-01-01

    Foreword; Preface; 1. Probability theory: basic notions; 2. Maximum and addition of random variables; 3. Continuous time limit, Ito calculus and path integrals; 4. Analysis of empirical data; 5. Financial products and financial markets; 6. Statistics of real prices: basic results; 7. Non-linear correlations and volatility fluctuations; 8. Skewness and price-volatility correlations; 9. Cross-correlations; 10. Risk measures; 11. Extreme correlations and variety; 12. Optimal portfolios; 13. Futures and options: fundamental concepts; 14. Options: hedging and residual risk; 15. Options: the role of drift and correlations; 16. Options: the Black and Scholes model; 17. Options: some more specific problems; 18. Options: minimum variance Monte-Carlo; 19. The yield curve; 20. Simple mechanisms for anomalous price statistics; Index of most important symbols; Index.

  15. Theory of Financial Risk and Derivative Pricing - 2nd Edition

    NASA Astrophysics Data System (ADS)

    Bouchaud, Jean-Philippe; Potters, Marc

    2003-12-01

    Foreword; Preface; 1. Probability theory: basic notions; 2. Maximum and addition of random variables; 3. Continuous time limit, Ito calculus and path integrals; 4. Analysis of empirical data; 5. Financial products and financial markets; 6. Statistics of real prices: basic results; 7. Non-linear correlations and volatility fluctuations; 8. Skewness and price-volatility correlations; 9. Cross-correlations; 10. Risk measures; 11. Extreme correlations and variety; 12. Optimal portfolios; 13. Futures and options: fundamental concepts; 14. Options: hedging and residual risk; 15. Options: the role of drift and correlations; 16. Options: the Black and Scholes model; 17. Options: some more specific problems; 18. Options: minimum variance Monte-Carlo; 19. The yield curve; 20. Simple mechanisms for anomalous price statistics; Index of most important symbols; Index.

  16. 454 next generation-sequencing outperforms allele-specific PCR, Sanger sequencing, and pyrosequencing for routine KRAS mutation analysis of formalin-fixed, paraffin-embedded samples

    PubMed Central

    Altimari, Annalisa; de Biase, Dario; De Maglio, Giovanna; Gruppioni, Elisa; Capizzi, Elisa; Degiovanni, Alessio; D’Errico, Antonia; Pession, Annalisa; Pizzolitto, Stefano; Fiorentino, Michelangelo; Tallini, Giovanni

    2013-01-01

    Detection of KRAS mutations in archival pathology samples is critical for therapeutic appropriateness of anti-EGFR monoclonal antibodies in colorectal cancer. We compared the sensitivity, specificity, and accuracy of Sanger sequencing, ARMS-Scorpion (TheraScreen®) real-time polymerase chain reaction (PCR), pyrosequencing, chip array hybridization, and 454 next-generation sequencing to assess KRAS codon 12 and 13 mutations in 60 nonconsecutive selected cases of colorectal cancer. Twenty of the 60 cases were detected as wild-type KRAS by all methods with 100% specificity. Among the 40 mutated cases, 13 were discrepant with at least one method. The sensitivity was 85%, 90%, 93%, and 92%, and the accuracy was 90%, 93%, 95%, and 95% for Sanger sequencing, TheraScreen real-time PCR, pyrosequencing, and chip array hybridization, respectively. The main limitation of Sanger sequencing was its low analytical sensitivity, whereas TheraScreen real-time PCR, pyrosequencing, and chip array hybridization showed higher sensitivity but suffered from the limitations of predesigned assays. Concordance between the methods was k = 0.79 for Sanger sequencing and k > 0.85 for the other techniques. Tumor cell enrichment correlated significantly with the abundance of KRAS-mutated deoxyribonucleic acid (DNA), evaluated as ΔCt for TheraScreen real-time PCR (P = 0.03), percentage of mutation for pyrosequencing (P = 0.001), ratio for chip array hybridization (P = 0.003), and percentage of mutation for 454 next-generation sequencing (P = 0.004). Also, 454 next-generation sequencing showed the best cross correlation for quantification of mutation abundance compared with all the other methods (P < 0.001). Our comparison showed the superiority of next-generation sequencing over the other techniques in terms of sensitivity and specificity. Next-generation sequencing will replace Sanger sequencing as the reference technique for diagnostic detection of KRAS mutation in archival tumor tissues. PMID:23950653

  17. Development of real time abdominal compression force monitoring and visual biofeedback system

    NASA Astrophysics Data System (ADS)

    Kim, Tae-Ho; Kim, Siyong; Kim, Dong-Su; Kang, Seong-Hee; Cho, Min-Seok; Kim, Kyeong-Hyeon; Shin, Dong-Seok; Suh, Tae-Suk

    2018-03-01

    In this study, we developed and evaluated a system that could monitor abdominal compression force (ACF) in real time and provide a surrogating signal, even under abdominal compression. The system could also provide visual-biofeedback (VBF). The real-time ACF monitoring system developed consists of an abdominal compression device, an ACF monitoring unit and a control system including an in-house ACF management program. We anticipated that ACF variation information caused by respiratory abdominal motion could be used as a respiratory surrogate signal. Four volunteers participated in this test to obtain correlation coefficients between ACF variation and tidal volumes. A simulation study with another group of six volunteers was performed to evaluate the feasibility of the proposed system. In the simulation, we investigated the reproducibility of the compression setup and proposed a further enhanced shallow breathing (ESB) technique using VBF by intentionally reducing the amplitude of the breathing range under abdominal compression. The correlation coefficient between the ACF variation caused by the respiratory abdominal motion and the tidal volume signal for each volunteer was evaluated and R 2 values ranged from 0.79 to 0.84. The ACF variation was similar to a respiratory pattern and slight variations of ACF ranges were observed among sessions. About 73-77% average ACF control rate (i.e. compliance) over five trials was observed in all volunteer subjects except one (64%) when there was no VBF. The targeted ACF range was intentionally reduced to achieve ESB for VBF simulation. With VBF, in spite of the reduced target range, overall ACF control rate improved by about 20% in all volunteers except one (4%), demonstrating the effectiveness of VBF. The developed monitoring system could help reduce the inter-fraction ACF set up error and the intra fraction ACF variation. With the capability of providing a real time surrogating signal and VBF under compression, it could improve the quality of respiratory tumor motion management in abdominal compression radiation therapy.

  18. Real-Time EEG Signal Enhancement Using Canonical Correlation Analysis and Gaussian Mixture Clustering

    PubMed Central

    Huang, Chih-Sheng; Yang, Wen-Yu; Chuang, Chun-Hsiang; Wang, Yu-Kai

    2018-01-01

    Electroencephalogram (EEG) signals are usually contaminated with various artifacts, such as signal associated with muscle activity, eye movement, and body motion, which have a noncerebral origin. The amplitude of such artifacts is larger than that of the electrical activity of the brain, so they mask the cortical signals of interest, resulting in biased analysis and interpretation. Several blind source separation methods have been developed to remove artifacts from the EEG recordings. However, the iterative process for measuring separation within multichannel recordings is computationally intractable. Moreover, manually excluding the artifact components requires a time-consuming offline process. This work proposes a real-time artifact removal algorithm that is based on canonical correlation analysis (CCA), feature extraction, and the Gaussian mixture model (GMM) to improve the quality of EEG signals. The CCA was used to decompose EEG signals into components followed by feature extraction to extract representative features and GMM to cluster these features into groups to recognize and remove artifacts. The feasibility of the proposed algorithm was demonstrated by effectively removing artifacts caused by blinks, head/body movement, and chewing from EEG recordings while preserving the temporal and spectral characteristics of the signals that are important to cognitive research. PMID:29599950

  19. Histologic, Serologic, and Molecular Analysis of Persistent Ehrlichiosis in a Murine Model

    PubMed Central

    Olano, Juan P.; Wen, Gary; Feng, Hui-Min; McBride, Jere W.; Walker, David H.

    2004-01-01

    Human monocytotropic ehrlichiosis caused by Ehrlichia chaffeensis was reported in 1987. An animal model to study acute fatal ehrlichiosis in mice that has been developed closely resembles the fatal form of human monocytotropic ehrlichiosis. However, animal models for persistent infection in the genus Ehrlichia in immunocompetent mice have not been characterized. We report the histopathological progression of Ehrlichia muris infection in immunocompetent mice (AKR and C57BL/6 strains) correlated with their antibody response determined by indirect immunofluorescence and Western immunoblotting, and the distribution and quantity of the ehrlichial load by immunohistochemistry, polymerase chain reaction (PCR), and real-time PCR in lungs, liver, and spleen. Mild to moderate correlation was observed between histopathological grading in these organs and relative ehrlichial loads. The highest ehrlichial loads were present between days 4 and 14 after infection. E. muris was detected in tissues examined up to 150 days after infection by real-time PCR. Analysis of the serological response revealed several immunodominant antigens, including 200-, 180-, 100-, 73/75-, 45-, and 28-kd proteins. In conclusion, we have provided for the first time a complete histopathological, serological, immunohistochemical, and quantitative analysis of an animal model for the study of persistent ehrlichial infection. PMID:15331423

  20. Intensity Maps Production Using Real-Time Joint Streaming Data Processing From Social and Physical Sensors

    NASA Astrophysics Data System (ADS)

    Kropivnitskaya, Y. Y.; Tiampo, K. F.; Qin, J.; Bauer, M.

    2015-12-01

    Intensity is one of the most useful measures of earthquake hazard, as it quantifies the strength of shaking produced at a given distance from the epicenter. Today, there are several data sources that could be used to determine intensity level which can be divided into two main categories. The first category is represented by social data sources, in which the intensity values are collected by interviewing people who experienced the earthquake-induced shaking. In this case, specially developed questionnaires can be used in addition to personal observations published on social networks such as Twitter. These observations are assigned to the appropriate intensity level by correlating specific details and descriptions to the Modified Mercalli Scale. The second category of data sources is represented by observations from different physical sensors installed with the specific purpose of obtaining an instrumentally-derived intensity level. These are usually based on a regression of recorded peak acceleration and/or velocity amplitudes. This approach relates the recorded ground motions to the expected felt and damage distribution through empirical relationships. The goal of this work is to implement and evaluate streaming data processing separately and jointly from both social and physical sensors in order to produce near real-time intensity maps and compare and analyze their quality and evolution through 10-minute time intervals immediately following an earthquake. Results are shown for the case study of the M6.0 2014 South Napa, CA earthquake that occurred on August 24, 2014. The using of innovative streaming and pipelining computing paradigms through IBM InfoSphere Streams platform made it possible to read input data in real-time for low-latency computing of combined intensity level and production of combined intensity maps in near-real time. The results compare three types of intensity maps created based on physical, social and combined data sources. Here we correlate the count and density of Tweets with intensity level and show the importance of processing combined data sources at the earliest time stages after earthquake happens. This method can supplement existing approaches of intensity level detection, especially in the regions with high number of Twitter users and low density of seismic networks.

  1. Real-Time Continuous Response Spectra Exceedance Calculation Displayed in a Web-Browser Enables Rapid and Robust Damage Evaluation by First Responders

    NASA Astrophysics Data System (ADS)

    Franke, M.; Skolnik, D. A.; Harvey, D.; Lindquist, K.

    2014-12-01

    A novel and robust approach is presented that provides near real-time earthquake alarms for critical structures at distributed locations and large facilities using real-time estimation of response spectra obtained from near free-field motions. Influential studies dating back to the 1980s identified spectral response acceleration as a key ground motion characteristic that correlates well with observed damage in structures. Thus, monitoring and reporting on exceedance of spectra-based thresholds are useful tools for assessing the potential for damage to facilities or multi-structure campuses based on input ground motions only. With as little as one strong-motion station per site, this scalable approach can provide rapid alarms on the damage status of remote towns, critical infrastructure (e.g., hospitals, schools) and points of interests (e.g., bridges) for a very large number of locations enabling better rapid decision making during critical and difficult immediate post-earthquake response actions. Details on the novel approach are presented along with an example implementation for a large energy company. Real-time calculation of PSA exceedance and alarm dissemination are enabled with Bighorn, an extension module based on the Antelope software package that combines real-time spectral monitoring and alarm capabilities with a robust built-in web display server. Antelope is an environmental data collection software package from Boulder Real Time Technologies (BRTT) typically used for very large seismic networks and real-time seismic data analyses. The primary processing engine produces continuous time-dependent response spectra for incoming acceleration streams. It utilizes expanded floating-point data representations within object ring-buffer packets and waveform files in a relational database. This leads to a very fast method for computing response spectra for a large number of channels. A Python script evaluates these response spectra for exceedance of one or more specified spectral limits, reporting any such exceedances via alarm packets that are put in the object ring-buffer for use by any alarm processes that need them. The web-display subsystem allows alert dissemination, interactive exploration, and alarm cancellation via the WWW.

  2. SU-F-J-54: Towards Real-Time Volumetric Imaging Using the Treatment Beam and KV Beam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, M; Rozario, T; Liu, A

    Purpose: Existing real-time imaging uses dual (orthogonal) kV beam fluoroscopies and may result in significant amount of extra radiation to patients, especially for prolonged treatment cases. In addition, kV projections only provide 2D information, which is insufficient for in vivo dose reconstruction. We propose real-time volumetric imaging using prior knowledge of pre-treatment 4D images and real-time 2D transit data of treatment beam and kV beam. Methods: The pre-treatment multi-snapshot volumetric images are used to simulate 2D projections of both the treatment beam and kV beam, respectively, for each treatment field defined by the control point. During radiation delivery, the transitmore » signals acquired by the electronic portal image device (EPID) are processed for every projection and compared with pre-calculation by cross-correlation for phase matching and thus 3D snapshot identification or real-time volumetric imaging. The data processing involves taking logarithmic ratios of EPID signals with respect to the air scan to reduce modeling uncertainties in head scatter fluence and EPID response. Simulated 2D projections are also used to pre-calculate confidence levels in phase matching. Treatment beam projections that have a low confidence level either in pre-calculation or real-time acquisition will trigger kV beams so that complementary information can be exploited. In case both the treatment beam and kV beam return low confidence in phase matching, a predicted phase based on linear regression will be generated. Results: Simulation studies indicated treatment beams provide sufficient confidence in phase matching for most cases. At times of low confidence from treatment beams, kV imaging provides sufficient confidence in phase matching due to its complementary configuration. Conclusion: The proposed real-time volumetric imaging utilizes the treatment beam and triggers kV beams for complementary information when the treatment beam along does not provide sufficient confidence for phase matching. This strategy minimizes the use of extra radiation to patients. This project is partially supported by a Varian MRA grant.« less

  3. Extending body space in immersive virtual reality: a very long arm illusion.

    PubMed

    Kilteni, Konstantina; Normand, Jean-Marie; Sanchez-Vives, Maria V; Slater, Mel

    2012-01-01

    Recent studies have shown that a fake body part can be incorporated into human body representation through synchronous multisensory stimulation on the fake and corresponding real body part - the most famous example being the Rubber Hand Illusion. However, the extent to which gross asymmetries in the fake body can be assimilated remains unknown. Participants experienced, through a head-tracked stereo head-mounted display a virtual body coincident with their real body. There were 5 conditions in a between-groups experiment, with 10 participants per condition. In all conditions there was visuo-motor congruence between the real and virtual dominant arm. In an Incongruent condition (I), where the virtual arm length was equal to the real length, there was visuo-tactile incongruence. In four Congruent conditions there was visuo-tactile congruence, but the virtual arm lengths were either equal to (C1), double (C2), triple (C3) or quadruple (C4) the real ones. Questionnaire scores and defensive withdrawal movements in response to a threat showed that the overall level of ownership was high in both C1 and I, and there was no significant difference between these conditions. Additionally, participants experienced ownership over the virtual arm up to three times the length of the real one, and less strongly at four times the length. The illusion did decline, however, with the length of the virtual arm. In the C2-C4 conditions although a measure of proprioceptive drift positively correlated with virtual arm length, there was no correlation between the drift and ownership of the virtual arm, suggesting different underlying mechanisms between ownership and drift. Overall, these findings extend and enrich previous results that multisensory and sensorimotor information can reconstruct our perception of the body shape, size and symmetry even when this is not consistent with normal body proportions.

  4. Extending Body Space in Immersive Virtual Reality: A Very Long Arm Illusion

    PubMed Central

    Kilteni, Konstantina; Normand, Jean-Marie; Sanchez-Vives, Maria V.; Slater, Mel

    2012-01-01

    Recent studies have shown that a fake body part can be incorporated into human body representation through synchronous multisensory stimulation on the fake and corresponding real body part – the most famous example being the Rubber Hand Illusion. However, the extent to which gross asymmetries in the fake body can be assimilated remains unknown. Participants experienced, through a head-tracked stereo head-mounted display a virtual body coincident with their real body. There were 5 conditions in a between-groups experiment, with 10 participants per condition. In all conditions there was visuo-motor congruence between the real and virtual dominant arm. In an Incongruent condition (I), where the virtual arm length was equal to the real length, there was visuo-tactile incongruence. In four Congruent conditions there was visuo-tactile congruence, but the virtual arm lengths were either equal to (C1), double (C2), triple (C3) or quadruple (C4) the real ones. Questionnaire scores and defensive withdrawal movements in response to a threat showed that the overall level of ownership was high in both C1 and I, and there was no significant difference between these conditions. Additionally, participants experienced ownership over the virtual arm up to three times the length of the real one, and less strongly at four times the length. The illusion did decline, however, with the length of the virtual arm. In the C2–C4 conditions although a measure of proprioceptive drift positively correlated with virtual arm length, there was no correlation between the drift and ownership of the virtual arm, suggesting different underlying mechanisms between ownership and drift. Overall, these findings extend and enrich previous results that multisensory and sensorimotor information can reconstruct our perception of the body shape, size and symmetry even when this is not consistent with normal body proportions. PMID:22829891

  5. Measuring Sea-Ice Motion in the Arctic with Real Time Photogrammetry

    NASA Astrophysics Data System (ADS)

    Brozena, J. M.; Hagen, R. A.; Peters, M. F.; Liang, R.; Ball, D.

    2014-12-01

    The U.S. Naval Research Laboratory, in coordination with other groups, has been collecting sea-ice data in the Arctic off the north coast of Alaska with an airborne system employing a radar altimeter, LiDAR and a photogrammetric camera in an effort to obtain wide swaths of measurements coincident with Cryosat-2 footprints. Because the satellite tracks traverse areas of moving pack ice, precise real-time estimates of the ice motion are needed to fly a survey grid that will yield complete data coverage. This requirement led us to develop a method to find the ice motion from the aircraft during the survey. With the advent of real-time orthographic photogrammetric systems, we developed a system that measures the sea ice motion in-flight, and also permits post-process modeling of sea ice velocities to correct the positioning of radar and LiDAR data. For the 2013 and 2014 field seasons, we used this Real Time Ice Motion Estimation (RTIME) system to determine ice motion using Applanix's Inflight Ortho software with an Applanix DSS439 system. Operationally, a series of photos were taken in the survey area. The aircraft then turned around and took more photos along the same line several minutes later. Orthophotos were generated within minutes of collection and evaluated by custom software to find photo footprints and potential overlap. Overlapping photos were passed to the correlation software, which selects a series of "chips" in the first photo and looks for the best matches in the second photo. The correlation results are then passed to a density-based clustering algorithm to determine the offset of the photo pair. To investigate any systematic errors in the photogrammetry, we flew several flight lines over a fixed point on various headings, over an area of non-moving ice in 2013. The orthophotos were run through the correlation software to find any residual offsets, and run through additional software to measure chip positions and offsets relative to the aircraft heading. X- and Y-offsets in situations where one of the chips was near the center of its photo were plotted to find the along- and across-track errors vs. distance from the photo center. Corrections were determined and applied to the survey data, reducing the mean error by about 1 meter. The corrections were applied to all of the subsequent survey data.

  6. Study of image matching algorithm and sub-pixel fitting algorithm in target tracking

    NASA Astrophysics Data System (ADS)

    Yang, Ming-dong; Jia, Jianjun; Qiang, Jia; Wang, Jian-yu

    2015-03-01

    Image correlation matching is a tracking method that searched a region most approximate to the target template based on the correlation measure between two images. Because there is no need to segment the image, and the computation of this method is little. Image correlation matching is a basic method of target tracking. This paper mainly studies the image matching algorithm of gray scale image, which precision is at sub-pixel level. The matching algorithm used in this paper is SAD (Sum of Absolute Difference) method. This method excels in real-time systems because of its low computation complexity. The SAD method is introduced firstly and the most frequently used sub-pixel fitting algorithms are introduced at the meantime. These fitting algorithms can't be used in real-time systems because they are too complex. However, target tracking often requires high real-time performance, we put forward a fitting algorithm named paraboloidal fitting algorithm based on the consideration above, this algorithm is simple and realized easily in real-time system. The result of this algorithm is compared with that of surface fitting algorithm through image matching simulation. By comparison, the precision difference between these two algorithms is little, it's less than 0.01pixel. In order to research the influence of target rotation on precision of image matching, the experiment of camera rotation was carried on. The detector used in the camera is a CMOS detector. It is fixed to an arc pendulum table, take pictures when the camera rotated different angles. Choose a subarea in the original picture as the template, and search the best matching spot using image matching algorithm mentioned above. The result shows that the matching error is bigger when the target rotation angle is larger. It's an approximate linear relation. Finally, the influence of noise on matching precision was researched. Gaussian noise and pepper and salt noise were added in the image respectively, and the image was processed by mean filter and median filter, then image matching was processed. The result show that when the noise is little, mean filter and median filter can achieve a good result. But when the noise density of salt and pepper noise is bigger than 0.4, or the variance of Gaussian noise is bigger than 0.0015, the result of image matching will be wrong.

  7. Evaluation of Augmented Reality Feedback in Surgical Training Environment.

    PubMed

    Zahiri, Mohsen; Nelson, Carl A; Oleynikov, Dmitry; Siu, Ka-Chun

    2018-02-01

    Providing computer-based laparoscopic surgical training has several advantages that enhance the training process. Self-evaluation and real-time performance feedback are 2 of these advantages, which avoid dependency of trainees on expert feedback. The goal of this study was to investigate the use of a visual time indicator as real-time feedback correlated with the laparoscopic surgical training. Twenty novices participated in this study working with (and without) different presentations of time indicators. They performed a standard peg transfer task, and their completion times and muscle activity were recorded and compared. Also of interest was whether the use of this type of feedback induced any side effect in terms of motivation or muscle fatigue. Of the 20 participants, 15 (75%) preferred using a time indicator in the training process rather than having no feedback. However, time to task completion showed no significant difference in performance with the time indicator; furthermore, no significant differences in muscle activity or muscle fatigue were detected with/without time feedback. The absence of significant difference between task performance with/without time feedback shows that using visual real-time feedback can be included in surgical training based on user preference. Trainees may benefit from this type of feedback in the form of increased motivation. The extent to which this can influence training frequency leading to performance improvement is a question for further study.

  8. Real-Time Earthquake Monitoring with Spatio-Temporal Fields

    NASA Astrophysics Data System (ADS)

    Whittier, J. C.; Nittel, S.; Subasinghe, I.

    2017-10-01

    With live streaming sensors and sensor networks, increasingly large numbers of individual sensors are deployed in physical space. Sensor data streams are a fundamentally novel mechanism to deliver observations to information systems. They enable us to represent spatio-temporal continuous phenomena such as radiation accidents, toxic plumes, or earthquakes almost as instantaneously as they happen in the real world. Sensor data streams discretely sample an earthquake, while the earthquake is continuous over space and time. Programmers attempting to integrate many streams to analyze earthquake activity and scope need to write code to integrate potentially very large sets of asynchronously sampled, concurrent streams in tedious application code. In previous work, we proposed the field stream data model (Liang et al., 2016) for data stream engines. Abstracting the stream of an individual sensor as a temporal field, the field represents the Earth's movement at the sensor position as continuous. This simplifies analysis across many sensors significantly. In this paper, we undertake a feasibility study of using the field stream model and the open source Data Stream Engine (DSE) Apache Spark(Apache Spark, 2017) to implement a real-time earthquake event detection with a subset of the 250 GPS sensor data streams of the Southern California Integrated GPS Network (SCIGN). The field-based real-time stream queries compute maximum displacement values over the latest query window of each stream, and related spatially neighboring streams to identify earthquake events and their extent. Further, we correlated the detected events with an USGS earthquake event feed. The query results are visualized in real-time.

  9. Schramm-Loewner evolution of the accessible perimeter of isoheight lines of correlated landscapes

    NASA Astrophysics Data System (ADS)

    Posé, N.; Schrenk, K. J.; Araújo, N. A. M.; Herrmann, H. J.

    Real landscapes exhibit long-range height-height correlations, which are quantified by the Hurst exponent H. We give evidence that for negative H, in spite of the long-range nature of correlations, the statistics of the accessible perimeter of isoheight lines is compatible with Schramm-Loewner evolution curves and therefore can be mapped to random walks, their fractal dimension determining the diffusion constant. Analytic results are recovered for H=-1 and H=0 and a conjecture is proposed for the values in between. By contrast, for positive H, we find that the random walk is not Markovian but strongly correlated in time. Theoretical and practical implications are discussed.

  10. Dynamic time-correlated single-photon counting laser ranging

    NASA Astrophysics Data System (ADS)

    Peng, Huan; Wang, Yu-rong; Meng, Wen-dong; Yan, Pei-qin; Li, Zhao-hui; Li, Chen; Pan, Hai-feng; Wu, Guang

    2018-03-01

    We demonstrate a photon counting laser ranging experiment with a four-channel single-photon detector (SPD). The multi-channel SPD improve the counting rate more than 4×107 cps, which makes possible for the distance measurement performed even in daylight. However, the time-correlated single-photon counting (TCSPC) technique cannot distill the signal easily while the fast moving targets are submersed in the strong background. We propose a dynamic TCSPC method for fast moving targets measurement by varying coincidence window in real time. In the experiment, we prove that targets with velocity of 5 km/s can be detected according to the method, while the echo rate is 20% with the background counts of more than 1.2×107 cps.

  11. Bold-line Monte Carlo and the nonequilibrium physics of strongly correlated many-body systems

    NASA Astrophysics Data System (ADS)

    Cohen, Guy

    2015-03-01

    This talk summarizes real time bold-line diagrammatic Monte-Carlo approaches to quantum impurity models, which make significant headway against the sign problem by summing over corrections to self-consistent diagrammatic expansions rather than a bare diagrammatic series. When the bold-line method is combined with reduced dynamics techniques both local single-time properties and two time correlators such as Green functions can be computed at very long timescales, enabling studies of nonequilibrium steady state behavior of quantum impurity models and creating new solvers for nonequilibrium dynamical mean field theory. This work is supported by NSF DMR 1006282, NSF CHE-1213247, DOE ER 46932, TG-DMR120085 and TG-DMR130036, and the Yad Hanadiv-Rothschild Foundation.

  12. An asymptotic theory for cross-correlation between auto-correlated sequences and its application on neuroimaging data.

    PubMed

    Zhou, Yunyi; Tao, Chenyang; Lu, Wenlian; Feng, Jianfeng

    2018-04-20

    Functional connectivity is among the most important tools to study brain. The correlation coefficient, between time series of different brain areas, is the most popular method to quantify functional connectivity. Correlation coefficient in practical use assumes the data to be temporally independent. However, the time series data of brain can manifest significant temporal auto-correlation. A widely applicable method is proposed for correcting temporal auto-correlation. We considered two types of time series models: (1) auto-regressive-moving-average model, (2) nonlinear dynamical system model with noisy fluctuations, and derived their respective asymptotic distributions of correlation coefficient. These two types of models are most commonly used in neuroscience studies. We show the respective asymptotic distributions share a unified expression. We have verified the validity of our method, and shown our method exhibited sufficient statistical power for detecting true correlation on numerical experiments. Employing our method on real dataset yields more robust functional network and higher classification accuracy than conventional methods. Our method robustly controls the type I error while maintaining sufficient statistical power for detecting true correlation in numerical experiments, where existing methods measuring association (linear and nonlinear) fail. In this work, we proposed a widely applicable approach for correcting the effect of temporal auto-correlation on functional connectivity. Empirical results favor the use of our method in functional network analysis. Copyright © 2018. Published by Elsevier B.V.

  13. Cerebellar Purkinje Cells Generate Highly Correlated Spontaneous Slow-Rate Fluctuations.

    PubMed

    Cao, Ying; Liu, Yu; Jaeger, Dieter; Heck, Detlef H

    2017-01-01

    Cerebellar Purkinje cells (PC) fire action potentials at high, sustained rates. Changes in spike rate that last a few tens of milliseconds encode sensory and behavioral events. Here we investigated spontaneous fluctuations of PC simple spike rate at a slow time scale of the order of 1 s. Simultaneous recordings from pairs of PCs that were aligned either along the sagittal or transversal axis of the cerebellar cortex revealed that simple spike rate fluctuations at the 1 s time scale were highly correlated. Each pair of PCs had either a predominantly positive or negative slow-rate correlation, with negative correlations observed only in PC pairs aligned along the transversal axis. Slow-rate correlations were independent of faster rate changes that were correlated with fluid licking behavior. Simultaneous recordings from PCs and cerebellar nuclear (CN) neurons showed that slow-rate fluctuations in PC and CN activity were also highly correlated, but their correlations continually alternated between periods of positive and negative correlation. The functional significance of this new aspect of cerebellar spike activity remains to be determined. Correlated slow-rate fluctuations seem too slow to be involved in the real-time control of ongoing behavior. However, slow-rate fluctuations of PCs converging on the same CN neuron are likely to modulate the excitability of the CN neuron, thus introduce a possible slow modulation of cerebellar output activity.

  14. Searching for structural medium changes during the 2011 El Hierro (Spain) submarine eruption

    NASA Astrophysics Data System (ADS)

    Sánchez-Pastor, Pilar S.; Schimmel, Martin; López, Carmen

    2017-04-01

    Submarine volcanic eruptions are often difficult to study due to their restricted access that usually inhibits direct observations. That happened with the 2011 El Hierro eruption, which is the first eruption that has been tracked in real time in Canary Islands. For instance, despite the real-time tracking it was not possible to determine the exact end of the eruption. Besides, volcanic eruptions involve many dynamic (physical and chemical) processes, which cause structural changes in the surrounding medium that we expect to observe and monitor through passive seismic approaches. The purpose of this study is to detect and analyse these changes as well as to search for precursory signals to the eruption itself using ambient noise auto and cross-correlations. We employ different correlation strategies (classical and phase cross-correlation) and apply them to field data recorded by the IGN network during 2011 and 2012. The different preprocessing and processing steps are tested and compared to better understand the data, to find the robust signatures, and to define a routine work procedure. One of the problems we face is the presence of volcanic tremors, which cause a varying seismic response that we can not attribute to structural changes. So far, structural changes could not be detected unambiguously and we present our ongoing research in this field.

  15. Cross-correlation-based earthquake relocation and ambient noise imaging at Axial Seamount

    NASA Astrophysics Data System (ADS)

    Tan, Y. J.; Waldhauser, F.; Tolstoy, M.; Wilcock, W. S. D.

    2016-12-01

    The seismic network that was installed on Axial Seamount as part of the Ocean Observatory Initiative's Cabled Array has been streaming live data since November 2014, encompassing an eruption in April-May of 2015. The network includes two broadband and five short-period seismometers spanning the southern half of the caldera. Almost 200,000 local earthquakes were detected in the first year of operation. Earthquake locations based on phase picks delineate outward dipping ring faults inferred to have accommodated deflation and guided dike propagation during the eruption (Wilcock et al., submitted). We will present results from our current effort of computing cross-correlation-based double-difference hypocenter locations to derive a more detailed image of the structures that provide insight into the active processes leading up to, during, and after the volcano's eruption. The new high-resolution hypocenters will form the base catalog for real-time double-difference monitoring of the seismicity recorded by the Cabled Array, allowing for high-precision evaluation of variation in seismogenic properties. We will also present results of measurements of temporal velocity changes associated with the eruption using seismic noise cross-correlations. This method has the potential to reveal areas of dike injection and magma withdrawal, as well as for real-time monitoring of temporal velocity variations associated with active volcanic processes.

  16. Neural Correlates of Fixation Duration during Real-world Scene Viewing: Evidence from Fixation-related (FIRE) fMRI.

    PubMed

    Henderson, John M; Choi, Wonil

    2015-06-01

    During active scene perception, our eyes move from one location to another via saccadic eye movements, with the eyes fixating objects and scene elements for varying amounts of time. Much of the variability in fixation duration is accounted for by attentional, perceptual, and cognitive processes associated with scene analysis and comprehension. For this reason, current theories of active scene viewing attempt to account for the influence of attention and cognition on fixation duration. Yet almost nothing is known about the neurocognitive systems associated with variation in fixation duration during scene viewing. We addressed this topic using fixation-related fMRI, which involves coregistering high-resolution eye tracking and magnetic resonance scanning to conduct event-related fMRI analysis based on characteristics of eye movements. We observed that activation in visual and prefrontal executive control areas was positively correlated with fixation duration, whereas activation in ventral areas associated with scene encoding and medial superior frontal and paracentral regions associated with changing action plans was negatively correlated with fixation duration. The results suggest that fixation duration in scene viewing is controlled by cognitive processes associated with real-time scene analysis interacting with motor planning, consistent with current computational models of active vision for scene perception.

  17. Accurate estimation of influenza epidemics using Google search data via ARGO

    PubMed Central

    Yang, Shihao; Santillana, Mauricio; Kou, S. C.

    2015-01-01

    Accurate real-time tracking of influenza outbreaks helps public health officials make timely and meaningful decisions that could save lives. We propose an influenza tracking model, ARGO (AutoRegression with GOogle search data), that uses publicly available online search data. In addition to having a rigorous statistical foundation, ARGO outperforms all previously available Google-search–based tracking models, including the latest version of Google Flu Trends, even though it uses only low-quality search data as input from publicly available Google Trends and Google Correlate websites. ARGO not only incorporates the seasonality in influenza epidemics but also captures changes in people’s online search behavior over time. ARGO is also flexible, self-correcting, robust, and scalable, making it a potentially powerful tool that can be used for real-time tracking of other social events at multiple temporal and spatial resolutions. PMID:26553980

  18. Real-space investigation of short-range magnetic correlations in fluoride pyrochlores NaCaCo 2F 7 and NaSrCo 2F 7 with magnetic pair distribution function analysis

    DOE PAGES

    Frandsen, Benjamin A.; Billinge, Simon J. L.; Ross, Kathryn A.; ...

    2017-12-29

    Here, we present time-of-flight neutron total scattering and polarized neutron scattering measurements of the magnetically frustrated compounds NaCaCo 2F 7 and NaSrCo 2F 7, which belong to a class of recently discovered pyrochlore compounds based on transition metals and fluorine. The magnetic pair distribution function (mPDF) technique is used to analyze and model the total scattering data in real space. We find that a previously-proposed model of short-range XY-like correlations with a length scale of 10-15 Å, combined with nearest-neighbor collinear antiferromagnetic correlations, accurately describes the mPDF data at low temperature, confirming the magnetic ground state in these materials. Thismore » model is further verified by the polarized neutron scattering data. From an analysis of the temperature dependence of the mPDF and polarized neutron scattering data, we find that short-range correlations persist on the nearest-neighbor length scale up to 200 K, approximately two orders of magnitude higher than the spin freezing temperatures of these compounds. These results highlight the opportunity presented by these new pyrochlore compounds to study the effects of geometric frustration at relatively high temperatures, while also advancing the mPDF technique and providing a novel opportunity to investigate a genuinely short-range-ordered magnetic ground state directly in real space.« less

  19. Real-space investigation of short-range magnetic correlations in fluoride pyrochlores NaCaCo 2F 7 and NaSrCo 2F 7 with magnetic pair distribution function analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frandsen, Benjamin A.; Billinge, Simon J. L.; Ross, Kathryn A.

    Here, we present time-of-flight neutron total scattering and polarized neutron scattering measurements of the magnetically frustrated compounds NaCaCo 2F 7 and NaSrCo 2F 7, which belong to a class of recently discovered pyrochlore compounds based on transition metals and fluorine. The magnetic pair distribution function (mPDF) technique is used to analyze and model the total scattering data in real space. We find that a previously-proposed model of short-range XY-like correlations with a length scale of 10-15 Å, combined with nearest-neighbor collinear antiferromagnetic correlations, accurately describes the mPDF data at low temperature, confirming the magnetic ground state in these materials. Thismore » model is further verified by the polarized neutron scattering data. From an analysis of the temperature dependence of the mPDF and polarized neutron scattering data, we find that short-range correlations persist on the nearest-neighbor length scale up to 200 K, approximately two orders of magnitude higher than the spin freezing temperatures of these compounds. These results highlight the opportunity presented by these new pyrochlore compounds to study the effects of geometric frustration at relatively high temperatures, while also advancing the mPDF technique and providing a novel opportunity to investigate a genuinely short-range-ordered magnetic ground state directly in real space.« less

  20. The correlation between preoperative volumetry and real graft weight: comparison of two volumetry programs.

    PubMed

    Mussin, Nadiar; Sumo, Marco; Lee, Kwang-Woong; Choi, YoungRok; Choi, Jin Yong; Ahn, Sung-Woo; Yoon, Kyung Chul; Kim, Hyo-Sin; Hong, Suk Kyun; Yi, Nam-Joon; Suh, Kyung-Suk

    2017-04-01

    Liver volumetry is a vital component in living donor liver transplantation to determine an adequate graft volume that meets the metabolic demands of the recipient and at the same time ensures donor safety. Most institutions use preoperative contrast-enhanced CT image-based software programs to estimate graft volume. The objective of this study was to evaluate the accuracy of 2 liver volumetry programs (Rapidia vs . Dr. Liver) in preoperative right liver graft estimation compared with real graft weight. Data from 215 consecutive right lobe living donors between October 2013 and August 2015 were retrospectively reviewed. One hundred seven patients were enrolled in Rapidia group and 108 patients were included in the Dr. Liver group. Estimated graft volumes generated by both software programs were compared with real graft weight measured during surgery, and further classified into minimal difference (≤15%) and big difference (>15%). Correlation coefficients and degree of difference were determined. Linear regressions were calculated and results depicted as scatterplots. Minimal difference was observed in 69.4% of cases from Dr. Liver group and big difference was seen in 44.9% of cases from Rapidia group (P = 0.035). Linear regression analysis showed positive correlation in both groups (P < 0.01). However, the correlation coefficient was better for the Dr. Liver group (R 2 = 0.719), than for the Rapidia group (R 2 = 0.688). Dr. Liver can accurately predict right liver graft size better and faster than Rapidia, and can facilitate preoperative planning in living donor liver transplantation.

  1. Real-space investigation of short-range magnetic correlations in fluoride pyrochlores NaCaCo2F7 and NaSrCo2F7 with magnetic pair distribution function analysis

    NASA Astrophysics Data System (ADS)

    Frandsen, Benjamin A.; Ross, Kate A.; Krizan, Jason W.; Nilsen, Gøran J.; Wildes, Andrew R.; Cava, Robert J.; Birgeneau, Robert J.; Billinge, Simon J. L.

    2017-12-01

    We present time-of-flight neutron total scattering and polarized neutron scattering measurements of the magnetically frustrated compounds NaCaCo2F7 and NaSrCo2F7 , which belong to a class of recently discovered pyrochlore compounds based on transition metals and fluorine. The magnetic pair distribution function (mPDF) technique is used to analyze and model the total scattering data in real space. We find that a previously proposed model of short-range XY-like correlations with a length scale of 10-15 Å, combined with nearest-neighbor collinear antiferromagnetic correlations, accurately describes the mPDF data at low temperature, confirming the magnetic ground state in these materials. This model is further verified by the polarized neutron scattering data. From an analysis of the temperature dependence of the mPDF and polarized neutron scattering data, we find that short-range correlations persist on the nearest-neighbor length scale up to 200 K, approximately two orders of magnitude higher than the spin freezing temperatures of these compounds. These results highlight the opportunity presented by these new pyrochlore compounds to study the effects of geometric frustration at relatively high temperatures, while also advancing the mPDF technique and providing an opportunity to investigate a genuinely short-range-ordered magnetic ground state directly in real space.

  2. Real-time fMRI neurofeedback of the mediodorsal and anterior thalamus enhances correlation between thalamic BOLD activity and alpha EEG rhythm.

    PubMed

    Zotev, Vadim; Misaki, Masaya; Phillips, Raquel; Wong, Chung Ki; Bodurka, Jerzy

    2018-02-01

    Real-time fMRI neurofeedback (rtfMRI-nf) with simultaneous EEG allows volitional modulation of BOLD activity of target brain regions and investigation of related electrophysiological activity. We applied this approach to study correlations between thalamic BOLD activity and alpha EEG rhythm. Healthy volunteers in the experimental group (EG, n = 15) learned to upregulate BOLD activity of the target region consisting of the mediodorsal (MD) and anterior (AN) thalamic nuclei using rtfMRI-nf during retrieval of happy autobiographical memories. Healthy subjects in the control group (CG, n = 14) were provided with a sham feedback. The EG participants were able to significantly increase BOLD activities of the MD and AN. Functional connectivity between the MD and the inferior precuneus was significantly enhanced during the rtfMRI-nf task. Average individual changes in the occipital alpha EEG power significantly correlated with the average MD BOLD activity levels for the EG. Temporal correlations between the occipital alpha EEG power and BOLD activities of the MD and AN were significantly enhanced, during the rtfMRI-nf task, for the EG compared to the CG. Temporal correlations with the alpha power were also significantly enhanced for the posterior nodes of the default mode network, including the precuneus/posterior cingulate, and for the dorsal striatum. Our findings suggest that the temporal correlation between the MD BOLD activity and posterior alpha EEG power is modulated by the interaction between the MD and the inferior precuneus, reflected in their functional connectivity. Our results demonstrate the potential of the rtfMRI-nf with simultaneous EEG for noninvasive neuromodulation studies of human brain function. © 2017 Wiley Periodicals, Inc.

  3. Behavioral and Neural Correlates of Imagined Walking and Walking-While-Talking in the Elderly

    PubMed Central

    Blumen, Helena M.; Holtzer, Roee; Brown, Lucy L.; Gazes, Yunglin; Verghese, Joe

    2014-01-01

    Cognition is important for locomotion and gait decline increases the risk for morbidity, mortality, cognitive decline, and dementia. Yet, the neural correlates of gait are not well established, because most neuroimaging methods cannot image the brain during locomotion. Imagined gait protocols overcome this limitation. This study examined the behavioral and neural correlates of a new imagined gait protocol that involved imagined walking (iW), imagined talking (iT), and imagined walking-while-talking (iWWT). In Experiment 1, 82 cognitively-healthy older adults (M = 80.45) walked (W), iW, walked while talking (WWT) and iWWT. Real and imagined walking task times were strongly correlated, particularly real and imagined dual-task times (WWT and iWWT). In Experiment 2, 33 cognitively-healthy older adults (M = 73.03) iW, iT, and iWWT during functional Magnetic Resonance Imaging. A multivariate Ordinal Trend (OrT) Covariance analysis identified a pattern of brain regions that: 1) varied as a function of imagery task difficulty (iW, iT and iWWT), 2) involved cerebellar, precuneus, supplementary motor and other prefrontal regions, and 3) were associated with kinesthetic imagery ratings and behavioral performance during actual WWT. This is the first study to compare the behavioral and neural correlates of imagined gait in single and dual-task situations, an issue that is particularly relevant to elderly populations. These initial findings encourage further research and development of this imagined gait protocol as a tool for improving gait and cognition among the elderly. PMID:24522972

  4. An investigation into the use of surface waves for the real-time inspection of polymer composites during fabrication

    NASA Astrophysics Data System (ADS)

    Linstrom, Elizabeth Jane

    A new approach to the nondestructive evaluation of polymer matrix/graphite fiber composites is presented. This technique permits the determination of the top ply bond strength of a laminate based on the results of ultrasonic testing. This technique is designed to be used for the real-time, nondestructive evaluation of composites during tape laying. By separately bonding the top ply of thermoset and thermoplastic polymer composite laminates, a poor ply bond was achieved solely at the interface of the top ply and the rest of the laminate. Using angled incidence, a 5 MHz, 4 musecond ultrasonic pulse was induced into the composite samples. This created waves traveling along the surface of the composite samples that were picked up by a receiving transducer. The received signal was cross-correlated with an artificially constructed replica of the input signal. The maximum amplitude of the cross-correlated signal was recorded. The cross-correlated signal was then converted to the frequency spectra using a fast Fourier transform. The maximum amplitude of the frequency spectra was then recorded. These measurements were repeated at 18 to 30 different locations on each composite sample. The resulting collection of maximum amplitudes of cross-correlated signals and frequency spectra were fit to two parameter Weibull distributions. The composite samples were destructively evaluated using a flat-wise tensile test. The B-basis values of the ultrasonic data Weibull distributions were compared to the B-basis values of the Weibull distribution of the strength data. A good correlation was found.

  5. Autofocus algorithm using one-dimensional Fourier transform and Pearson correlation

    NASA Astrophysics Data System (ADS)

    Bueno Mario, A.; Alvarez-Borrego, Josue; Acho, L.

    2004-10-01

    A new autofocus algorithm based on one-dimensional Fourier transform and Pearson correlation for Z automatized microscope is proposed. Our goal is to determine in fast response time and accuracy, the best focused plane through an algorithm. We capture in bright and dark field several images set at different Z distances from biological organism sample. The algorithm uses the one-dimensional Fourier transform to obtain the image frequency content of a vectors pattern previously defined comparing the Pearson correlation of these frequency vectors versus the reference image frequency vector, the most out of focus image, we find the best focusing. Experimental results showed the algorithm has fast response time and accuracy in getting the best focus plane from captured images. In conclusions, the algorithm can be implemented in real time systems due fast response time, accuracy and robustness. The algorithm can be used to get focused images in bright and dark field and it can be extended to include fusion techniques to construct multifocus final images beyond of this paper.

  6. Parameter Optimization for Selected Correlation Analysis of Intracranial Pathophysiology.

    PubMed

    Faltermeier, Rupert; Proescholdt, Martin A; Bele, Sylvia; Brawanski, Alexander

    2015-01-01

    Recently we proposed a mathematical tool set, called selected correlation analysis, that reliably detects positive and negative correlations between arterial blood pressure (ABP) and intracranial pressure (ICP). Such correlations are associated with severe impairment of the cerebral autoregulation and intracranial compliance, as predicted by a mathematical model. The time resolved selected correlation analysis is based on a windowing technique combined with Fourier-based coherence calculations and therefore depends on several parameters. For real time application of this method at an ICU it is inevitable to adjust this mathematical tool for high sensitivity and distinct reliability. In this study, we will introduce a method to optimize the parameters of the selected correlation analysis by correlating an index, called selected correlation positive (SCP), with the outcome of the patients represented by the Glasgow Outcome Scale (GOS). For that purpose, the data of twenty-five patients were used to calculate the SCP value for each patient and multitude of feasible parameter sets of the selected correlation analysis. It could be shown that an optimized set of parameters is able to improve the sensitivity of the method by a factor greater than four in comparison to our first analyses.

  7. Parameter Optimization for Selected Correlation Analysis of Intracranial Pathophysiology

    PubMed Central

    Faltermeier, Rupert; Proescholdt, Martin A.; Bele, Sylvia; Brawanski, Alexander

    2015-01-01

    Recently we proposed a mathematical tool set, called selected correlation analysis, that reliably detects positive and negative correlations between arterial blood pressure (ABP) and intracranial pressure (ICP). Such correlations are associated with severe impairment of the cerebral autoregulation and intracranial compliance, as predicted by a mathematical model. The time resolved selected correlation analysis is based on a windowing technique combined with Fourier-based coherence calculations and therefore depends on several parameters. For real time application of this method at an ICU it is inevitable to adjust this mathematical tool for high sensitivity and distinct reliability. In this study, we will introduce a method to optimize the parameters of the selected correlation analysis by correlating an index, called selected correlation positive (SCP), with the outcome of the patients represented by the Glasgow Outcome Scale (GOS). For that purpose, the data of twenty-five patients were used to calculate the SCP value for each patient and multitude of feasible parameter sets of the selected correlation analysis. It could be shown that an optimized set of parameters is able to improve the sensitivity of the method by a factor greater than four in comparison to our first analyses. PMID:26693250

  8. Software Correlator for Radioastron Mission

    NASA Astrophysics Data System (ADS)

    Likhachev, Sergey F.; Kostenko, Vladimir I.; Girin, Igor A.; Andrianov, Andrey S.; Rudnitskiy, Alexey G.; Zharov, Vladimir E.

    In this paper, we discuss the characteristics and operation of Astro Space Center (ASC) software FX correlator that is an important component of space-ground interferometer for Radioastron project. This project performs joint observations of compact radio sources using 10m space radio telescope (SRT) together with ground radio telescopes at 92, 18, 6 and 1.3 cm wavelengths. In this paper, we describe the main features of space-ground VLBI data processing of Radioastron project using ASC correlator. Quality of implemented fringe search procedure provides positive results without significant losses in correlated amplitude. ASC Correlator has a computational power close to real time operation. The correlator has a number of processing modes: “Continuum”, “Spectral Line”, “Pulsars”, “Giant Pulses”,“Coherent”. Special attention is paid to peculiarities of Radioastron space-ground VLBI data processing. The algorithms of time delay and delay rate calculation are also discussed, which is a matter of principle for data correlation of space-ground interferometers. During five years of Radioastron SRT successful operation, ASC correlator showed high potential of satisfying steady growing needs of current and future ground and space VLBI science. Results of ASC software correlator operation are demonstrated.

  9. A robust adaptive denoising framework for real-time artifact removal in scalp EEG measurements

    NASA Astrophysics Data System (ADS)

    Kilicarslan, Atilla; Grossman, Robert G.; Contreras-Vidal, Jose Luis

    2016-04-01

    Objective. Non-invasive measurement of human neural activity based on the scalp electroencephalogram (EEG) allows for the development of biomedical devices that interface with the nervous system for scientific, diagnostic, therapeutic, or restorative purposes. However, EEG recordings are often considered as prone to physiological and non-physiological artifacts of different types and frequency characteristics. Among them, ocular artifacts and signal drifts represent major sources of EEG contamination, particularly in real-time closed-loop brain-machine interface (BMI) applications, which require effective handling of these artifacts across sessions and in natural settings. Approach. We extend the usage of a robust adaptive noise cancelling (ANC) scheme ({H}∞ filtering) for removal of eye blinks, eye motions, amplitude drifts and recording biases simultaneously. We also characterize the volume conduction, by estimating the signal propagation levels across all EEG scalp recording areas due to ocular artifact generators. We find that the amplitude and spatial distribution of ocular artifacts vary greatly depending on the electrode location. Therefore, fixed filtering parameters for all recording areas would naturally hinder the true overall performance of an ANC scheme for artifact removal. We treat each electrode as a separate sub-system to be filtered, and without the loss of generality, they are assumed to be uncorrelated and uncoupled. Main results. Our results show over 95-99.9% correlation between the raw and processed signals at non-ocular artifact regions, and depending on the contamination profile, 40-70% correlation when ocular artifacts are dominant. We also compare our results with the offline independent component analysis and artifact subspace reconstruction methods, and show that some local quantities are handled better by our sample-adaptive real-time framework. Decoding performance is also compared with multi-day experimental data from 2 subjects, totaling 19 sessions, with and without {H}∞ filtering of the raw data. Significance. The proposed method allows real-time adaptive artifact removal for EEG-based closed-loop BMI applications and mobile EEG studies in general, thereby increasing the range of tasks that can be studied in action and context while reducing the need for discarding data due to artifacts. Significant increase in decoding performances also justify the effectiveness of the method to be used in real-time closed-loop BMI applications.

  10. Real-time monitoring of laser hot-wire cladding of Inconel 625

    NASA Astrophysics Data System (ADS)

    Liu, Shuang; Liu, Wei; Harooni, Masoud; Ma, Junjie; Kovacevic, Radovan

    2014-10-01

    Laser hot-wire cladding (LHWC), characterized by resistance heating of the wire, largely increases the productivity and saves the laser energy. However, the main issue of applying this method is the occurrence of arcing which causes spatters and affects the stability of the process. In this study, an optical spectrometer was used for real-time monitoring of the LHWC process. The corresponding plasma intensity was analyzed under various operating conditions. The electron temperature of the plasma was calculated for elements of nickel and chromium that mainly comprised the plasma plume. There was a correlation between the electron temperature and the stability of the process. The characteristics of the resulted clad were also investigated by measuring the dilution, hardness and microstructure.

  11. Native denaturation differential scanning fluorimetry: Determining the effect of urea using a quantitative real-time thermocycler.

    PubMed

    Childers, Christine L; Green, Stuart R; Dawson, Neal J; Storey, Kenneth B

    2016-09-01

    The effect of protein stability on kinetic function is monitored with many techniques that often require large amounts of expensive substrates and specialized equipment not universally available. We present differential scanning fluorimetry (DSF), a simple high-throughput assay performed in real-time thermocyclers, as a technique for analysis of protein unfolding. Furthermore, we demonstrate a correlation between the half-maximal rate of protein unfolding (Knd), and protein unfolding by urea (I50). This demonstrates that DSF methods can determine the structural stability of an enzyme's active site and can compare the relative structural stability of homologous enzymes with a high degree of sequence similarity. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Smart catheter flow sensor for real-time continuous regional cerebral blood flow monitoring

    NASA Astrophysics Data System (ADS)

    Li, Chunyan; Wu, Pei-Ming; Hartings, Jed A.; Wu, Zhizhen; Ahn, Chong H.; LeDoux, David; Shutter, Lori A.; Narayan, Raj K.

    2011-12-01

    We present a smart catheter flow sensor for real-time, continuous, and quantitative measurement of regional cerebral blood flow using in situ temperature and thermal conductivity compensation. The flow sensor operates in a constant-temperature mode and employs a periodic heating and cooling technique. This approach ensures zero drift and provides highly reliable data with microelectromechanical system-based thin film sensors. The developed flow sensor has a sensitivity of 0.973 mV/ml/100 g/min in the range from 0 to 160 ml/100 g/min with a linear correlation coefficient of R2 = 0.9953. It achieves a resolution of 0.25 ml/100 g/min and an accuracy better than 5 ml/100 g/min.

  13. Colometer: a real-time quality feedback system for screening colonoscopy.

    PubMed

    Filip, Dobromir; Gao, Xuexin; Angulo-Rodríguez, Leticia; Mintchev, Martin P; Devlin, Shane M; Rostom, Alaa; Rosen, Wayne; Andrews, Christopher N

    2012-08-28

    To investigate the performance of a new software-based colonoscopy quality assessment system. The software-based system employs a novel image processing algorithm which detects the levels of image clarity, withdrawal velocity, and level of the bowel preparation in a real-time fashion from live video signal. Threshold levels of image blurriness and the withdrawal velocity below which the visualization could be considered adequate have initially been determined arbitrarily by review of sample colonoscopy videos by two experienced endoscopists. Subsequently, an overall colonoscopy quality rating was computed based on the percentage of the withdrawal time with adequate visualization (scored 1-5; 1, when the percentage was 1%-20%; 2, when the percentage was 21%-40%, etc.). In order to test the proposed velocity and blurriness thresholds, screening colonoscopy withdrawal videos from a specialized ambulatory colon cancer screening center were collected, automatically processed and rated. Quality ratings on the withdrawal were compared to the insertion in the same patients. Then, 3 experienced endoscopists reviewed the collected videos in a blinded fashion and rated the overall quality of each withdrawal (scored 1-5; 1, poor; 3, average; 5, excellent) based on 3 major aspects: image quality, colon preparation, and withdrawal velocity. The automated quality ratings were compared to the averaged endoscopist quality ratings using Spearman correlation coefficient. Fourteen screening colonoscopies were assessed. Adenomatous polyps were detected in 4/14 (29%) of the collected colonoscopy video samples. As a proof of concept, the Colometer software rated colonoscope withdrawal as having better visualization than the insertion in the 10 videos which did not have any polyps (average percent time with adequate visualization: 79% ± 5% for withdrawal and 50% ± 14% for insertion, P < 0.01). Withdrawal times during which no polyps were removed ranged from 4-12 min. The median quality rating from the automated system and the reviewers was 3.45 [interquartile range (IQR), 3.1-3.68] and 3.00 (IQR, 2.33-3.67) respectively for all colonoscopy video samples. The automated rating revealed a strong correlation with the reviewer's rating (ρ coefficient= 0.65, P = 0.01). There was good correlation of the automated overall quality rating and the mean endoscopist withdrawal speed rating (Spearman r coefficient= 0.59, P = 0.03). There was no correlation of automated overall quality rating with mean endoscopists image quality rating (Spearman r coefficient= 0.41, P = 0.15). The results from a novel automated real-time colonoscopy quality feedback system strongly agreed with the endoscopists' quality assessments. Further study is required to validate this approach.

  14. A novel tool for continuous fracture aftercare - Clinical feasibility and first results of a new telemetric gait analysis insole.

    PubMed

    Braun, Benedikt J; Bushuven, Eva; Hell, Rebecca; Veith, Nils T; Buschbaum, Jan; Holstein, Joerg H; Pohlemann, Tim

    2016-02-01

    Weight bearing after lower extremity fractures still remains a highly controversial issue. Even in ankle fractures, the most common lower extremity injury no standard aftercare protocol has been established. Average non weight bearing times range from 0 to 7 weeks, with standardised, radiological healing controls at fixed time intervals. Recent literature calls for patient-adapted aftercare protocols based on individual fracture and load scenarios. We show the clinical feasibility and first results of a new, insole embedded gait analysis tool for continuous monitoring of gait, load and activity. Ten patients were monitored with a new, independent gait analysis insole for up to 3 months postoperatively. Strict 20 kg partial weight bearing was ordered for 6 weeks. Overall activity, load spectrum, ground reaction forces, clinical scoring and general health data were recorded and correlated. Statistical analysis with power analysis, t-test and Spearman correlation was performed. Only one patient completely adhered to the set weight bearing limit. Average time in minutes over the limit was 374 min. Based on the parameters load, activity, gait time over 20 kg weight bearing and maximum ground reaction force high and low performers were defined after 3 weeks. Significant difference in time to painless full weight bearing between high and low performers was shown. Correlation analysis revealed a significant correlation between weight bearing and clinical scoring as well as pain (American Orthopaedic Foot and Ankle Society (AOFAS) Score rs=0.74; Olerud-Molander Score rs=0.93; VAS pain rs=-0.95). Early, continuous gait analysis is able to define aftercare performers with significant differences in time to full painless weight bearing where clinical or radiographic controls could not. Patient compliance to standardised weight bearing limits and protocols is low. Highly individual rehabilitation patterns were seen in all patients. Aftercare protocols should be adjusted to real-time patient conditions, rather than fixed intervals and limits. With a real-time measuring device high performers could be identified and influenced towards optimal healing conditions early, while low performers are recognised and missing healing influences could be corrected according to patient condition. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. A similarity hypothesis for the two-point correlation tensor in a temporally evolving plane wake

    NASA Technical Reports Server (NTRS)

    Ewing, D. W.; George, W. K.; Moser, R. D.; Rogers, M. M.

    1995-01-01

    The analysis demonstrated that the governing equations for the two-point velocity correlation tensor in the temporally evolving wake admit similarity solutions, which include the similarity solutions for the single-point moment as a special case. The resulting equations for the similarity solutions include two constants, beta and Re(sub sigma), that are ratios of three characteristic time scales of processes in the flow: a viscous time scale, a time scale characteristic of the spread rate of the flow, and a characteristic time scale of the mean strain rate. The values of these ratios depend on the initial conditions of the flow and are most likely measures of the coherent structures in the initial conditions. The occurrences of these constants in the governing equations for the similarity solutions indicates that these solutions, in general, will only be the same for two flows if these two constants are equal (and hence the coherent structures in the flows are related). The comparisons between the predictions of the similarity hypothesis and the data presented here and elsewhere indicate that the similarity solutions for the two-point correlation tensors provide a good approximation of the measures of those motions that are not significantly affected by the boundary conditions caused by the finite extent of real flows. Thus, the two-point similarity hypothesis provides a useful tool for both numerical and physical experimentalist that can be used to examine how the finite extent of real flows affect the evolution of the different scales of motion in the flow.

  16. Bubble-Induced Color Doppler Feedback for Histotripsy Tissue Fractionation.

    PubMed

    Miller, Ryan M; Zhang, Xi; Maxwell, Adam D; Cain, Charles A; Xu, Zhen

    2016-03-01

    Histotripsy therapy produces cavitating bubble clouds to increasingly fractionate and eventually liquefy tissue using high-intensity ultrasound pulses. Following cavitation generated by each pulse, coherent motion of the cavitation residual nuclei can be detected using metrics formed from ultrasound color Doppler acquisitions. In this paper, three experiments were performed to investigate the characteristics of this motion as real-time feedback on histotripsy tissue fractionation. In the first experiment, bubble-induced color Doppler (BCD) and particle image velocimetry (PIV) analysis monitored the residual cavitation nuclei in the treatment region in an agarose tissue phantom treated with two-cycle histotripsy pulses at [Formula: see text] using a 500-kHz transducer. Both BCD and PIV results showed brief chaotic motion of the residual nuclei followed by coherent motion first moving away from the transducer and then rebounding back. Velocity measurements from both PIV and BCD agreed well, showing a monotonic increase in rebound time up to a saturation point for increased therapy dose. In a second experiment, a thin layer of red blood cells (RBC) was added to the phantom to allow quantification of the fractionation of the RBC layer to compare with BCD metrics. A strong linear correlation was observed between the fractionation level and the time to BCD peak rebound velocity over histotripsy treatment. Finally, the correlation between BCD feedback and histotripsy tissue fractionation was validated in ex vivo porcine liver evaluated histologically. BCD metrics showed strong linear correlation with fractionation progression, suggesting that BCD provides useful quantitative real-time feedback on histotripsy treatment progression.

  17. Bubble-induced Color Doppler Feedback for Histotripsy Tissue Fractionation

    PubMed Central

    Miller, Ryan M.; Zhang, Xi; Maxwell, Adam; Cain, Charles; Xu, Zhen

    2016-01-01

    Histotripsy therapy produces cavitating bubble clouds to increasingly fractionate and eventually liquefy tissue using high intensity ultrasound pulses. Following cavitation generated by each pulse, coherent motion of the cavitation residual nuclei can be detected using metrics formed from ultrasound color Doppler acquisitions. In this paper, three experiments were performed to investigate the characteristics of this motion as real-time feedback on histotripsy tissue fractionation. In the first experiment, bubble-induced color Doppler (BCD) and particle image velocimetry (PIV) analysis monitored the residual cavitation nuclei in the treatment region in an agarose tissue phantom treated with 2-cycle histotripsy pulses at > 30 MPa using a 500 kHz transducer. Both BCD and PIV results showed brief chaotic motion of the residual nuclei followed by coherent motion first moving away from the transducer and then rebounding back. Velocity measurements from both PIV and BCD agreed well, showing a monotonic increase in rebound time up to a saturation point for increased therapy dose. In a second experiment, a thin layer of red blood cells (RBC) was added to the phantom to allow quantification of the fractionation of the RBC layer to compare with BCD metrics. A strong linear correlation was observed between the fractionation level and the time to BCD peak rebound velocity over histotripsy treatment. Finally, the correlation between BCD feedback and histotripsy tissue fractionation was validated in ex vivo porcine liver evaluated histologically. BCD metrics showed strong linear correlation with fractionation progression, suggesting that BCD provides useful quantitative real-time feedback on histotripsy treatment progression. PMID:26863659

  18. Comparison between xCELLigence biosensor technology and conventional cell culture system for real-time monitoring human tenocytes proliferation and drugs cytotoxicity screening.

    PubMed

    Chiu, Chih-Hao; Lei, Kin Fong; Yeh, Wen-Ling; Chen, Poyu; Chan, Yi-Sheng; Hsu, Kuo-Yao; Chen, Alvin Chao-Yu

    2017-10-16

    Local injections of anesthetics, NSAIDs, and corticosteroids for tendinopathies are empirically used. They are believed to have some cytotoxicity toward tenocytes. The maximal efficacy dosages of local injections should be determined. A commercial 2D microfluidic xCELLigence system had been developed to detect real-time cellular proliferation and their responses to different stimuli and had been used in several biomedical applications. The purpose of this study is to determine if human tenocytes can successfully proliferate inside xCELLigence system and the result has high correlation with conventional cell culture methods in the same condition. First passage of human tenocytes was seeded in xCELLigence and conventional 24-well plates. Ketorolac tromethamine, bupivacaine, methylprednisolone, and betamethasone with different concentrations (100, 50, and 10% diluted of clinical usage) were exposed in both systems. Gene expression of type I collagen, type III collagen, tenascin-C, decorin, and scleraxis were compared between two systems. Human tenocytes could proliferate both in xCELLigence and conventional cell culture systems. Cytotoxicity of each drug revealed dose-dependency when exposed to tenocytes in both systems. Significance was found between groups. All the four drugs had comparable cytotoxicity in their 100% concentration. When 50% concentration was used, betamethasone had a relatively decreased cytotoxicity among them in xCELLigence but not in conventional culture. When 10% concentration was used, betamethasone had the least cytotoxicity. Strong and positive correlation was found between cell index of xCELLigence and result of WST-1 assay (Pearson's correlation [r] = 0.914). Positive correlation of gene expression between tenocytes in xCELLigence and conventional culture was also observed. Type I collagen: [r] = 0.823; type III collagen: [r] = 0.899; tenascin-C: [r] = 0.917; decorin: [r] = 0.874; and scleraxis: [r] = 0.965. Human tenocytes could proliferate inside xCELLigence system. These responses varied when tenocytes were exposed to different concentrations of ketorolac tromethamine, bupivacaine, methylprednisolone, and betamethasone. The result of cell proliferation and gene expression of tenocytes in both xCELLigence and conventional culture system is strongly correlated. xCELLigence culture system may replace conventional cell culture, which made real-time tenocyte proliferation monitoring possible.

  19. Coincidence ion imaging with a fast frame camera

    NASA Astrophysics Data System (ADS)

    Lee, Suk Kyoung; Cudry, Fadia; Lin, Yun Fei; Lingenfelter, Steven; Winney, Alexander H.; Fan, Lin; Li, Wen

    2014-12-01

    A new time- and position-sensitive particle detection system based on a fast frame CMOS (complementary metal-oxide semiconductors) camera is developed for coincidence ion imaging. The system is composed of four major components: a conventional microchannel plate/phosphor screen ion imager, a fast frame CMOS camera, a single anode photomultiplier tube (PMT), and a high-speed digitizer. The system collects the positional information of ions from a fast frame camera through real-time centroiding while the arrival times are obtained from the timing signal of a PMT processed by a high-speed digitizer. Multi-hit capability is achieved by correlating the intensity of ion spots on each camera frame with the peak heights on the corresponding time-of-flight spectrum of a PMT. Efficient computer algorithms are developed to process camera frames and digitizer traces in real-time at 1 kHz laser repetition rate. We demonstrate the capability of this system by detecting a momentum-matched co-fragments pair (methyl and iodine cations) produced from strong field dissociative double ionization of methyl iodide.

  20. Real-Time Tracking of the Extreme Rainfall of Hurricanes Harvey, Irma, and Maria using UCI CHRS's iRain System

    NASA Astrophysics Data System (ADS)

    Shearer, E. J.; Nguyen, P.; Ombadi, M.; Palacios, T.; Huynh, P.; Furman, D.; Tran, H.; Braithwaite, D.; Hsu, K. L.; Sorooshian, S.; Logan, W. S.

    2017-12-01

    During the 2017 hurricane season, three major hurricanes-Harvey, Irma, and Maria-devastated the Atlantic coast of the US and the Caribbean Islands. Harvey set the record for the rainiest storm in continental US history, Irma was the longest-lived powerful hurricane ever observed, and Maria was the costliest storm in Puerto Rican history. The recorded maximum precipitation totals for these storms were 65, 16, and 20 inches respectively. These events provided the Center for Hydrometeorology and Remote Sensing (CHRS) an opportunity to test its global real-time satellite precipitation observation system, iRain, for extreme storm events. The iRain system has been under development through a collaboration between CHRS at the University of California, Irvine (UCI) and UNESCO's International Hydrological Program (IHP). iRain provides near real-time high resolution (0.04°, approx. 4km) global (60°N - 60°S) satellite precipitation data estimated by the PERSIANN-Cloud Classification System (PERSIANN-CCS) algorithm developed by the scientists at CHRS. The user-interactive and web-accessible iRain system allows users to visualize and download real-time global satellite precipitation estimates and track the development and path of the current 50 largest storms globally from data generated by the PERSIANN-CCS algorithm. iRain continuously proves to be an effective tool for measuring real-time precipitation amounts of extreme storms-especially in locations that do not have extensive rain gauge or radar coverage. Such areas include large portions of the world's oceans and over continents such as Africa and Asia. CHRS also created a mobile app version of the system named "iRain UCI", available for iOS and Android devices. During these storms, real-time rainfall data generated by PERSIANN-CCS was consistently comparable to radar and rain gauge data. This presentation evaluates iRain's efficiency as a tool for extreme precipitation monitoring and provides an evaluation of the PERSIANN-CCS real-time rainfall estimates during Hurricanes Harvey, Irma, and Maria in relation to radar and rain gauge data using continuous (correlation, root mean square error, and bias) and categorical (POD and FAR) indices. These results present the relative skill of PERSIANN-CCS real-time data to radar and rain gauge data.

  1. MONITORING FECAL INDICATOR BACTERIA WITH ALTERNATIVE REAL-TIME PCR INSTRUMENTS TO ASSESS HEALTH RISKS ASSOCIATED WITH RECREATIONAL WATER USE

    EPA Science Inventory

    U.S. EPA guidance on the safety of surface waters for recreational use is currently based on epidemiological studies conducted in the 1980?s that demonstrated a strong positive correlation between bathing-associated illness rates and concentrations of culturable fecal indicator b...

  2. Application of wearable optical coherence tomography (OCT) and loop-mediated isothermal amplification (LAMP) techniques for in situ real-time field inspection of apple Marssonina blotch disease

    NASA Astrophysics Data System (ADS)

    Wijesinghe, Ruchire Eranga; Lee, Seung-Yeol; Ravichandran, Naresh Kumar; Shirazi, Muhammad Faizan; Han, Sangyeop; Jeong, Hyosang; Kim, Pilun; Jung, Hee-Young; Jeon, Mansik; Kim, Jeehyun

    2017-04-01

    Here we describe the possible application of optical coherence tomography (OCT) to inspect Marssonina coronaria infected apple blotch disease of in situ apple leaves. To fulfill the in situ field inspection requirement, we developed a compact wearable OCT system. For the confirmation of OCT results, simultaneous experiment was performed in realtime using loop-mediated isothermal amplification (LAMP), which is frequently used in agriculture. LAMP method was developed as an alternative approach for the inspection of disease. We performed field inspection for 30 consecutive days, and all the acquired results from both OCT and lamp were compared to confirm the correlation. A clear identification between healthy specimens, apparently healthy but infected specimens, and infected specimens could be obtained through the real-time OCT images, and the correlation between OCT and lamp results was confirmed through the obtained realtime lamp results. Based on this feasibility study, we conclude that the combination of both these diagnosing modalities can be effective for various novel agricultural discoveries.

  3. Detection of Streptococcus mutans Genomic DNA in Human DNA Samples Extracted from Saliva and Blood

    PubMed Central

    Vieira, Alexandre R.; Deeley, Kathleen B.; Callahan, Nicholas F.; Noel, Jacqueline B.; Anjomshoaa, Ida; Carricato, Wendy M.; Schulhof, Louise P.; DeSensi, Rebecca S.; Gandhi, Pooja; Resick, Judith M.; Brandon, Carla A.; Rozhon, Christopher; Patir, Asli; Yildirim, Mine; Poletta, Fernando A.; Mereb, Juan C.; Letra, Ariadne; Menezes, Renato; Wendell, Steven; Lopez-Camelo, Jorge S.; Castilla, Eduardo E.; Orioli, Iêda M.; Seymen, Figen; Weyant, Robert J.; Crout, Richard; McNeil, Daniel W.; Modesto, Adriana; Marazita, Mary L.

    2011-01-01

    Caries is a multifactorial disease, and studies aiming to unravel the factors modulating its etiology must consider all known predisposing factors. One major factor is bacterial colonization, and Streptococcus mutans is the main microorganism associated with the initiation of the disease. In our studies, we have access to DNA samples extracted from human saliva and blood. In this report, we tested a real-time PCR assay developed to detect copies of genomic DNA from Streptococcus mutans in 1,424 DNA samples from humans. Our results suggest that we can determine the presence of genomic DNA copies of Streptococcus mutans in both DNA samples from caries-free and caries-affected individuals. However, we were not able to detect the presence of genomic DNA copies of Streptococcus mutans in any DNA samples extracted from peripheral blood, which suggests the assay may not be sensitive enough for this goal. Values of the threshold cycle of the real-time PCR reaction correlate with higher levels of caries experience in children, but this correlation could not be detected for adults. PMID:21731912

  4. Development of a real time monitor and multivariate method for long term diagnostics of atmospheric pressure dielectric barrier discharges: application to He, He/N2, and He/O2 discharges.

    PubMed

    O'Connor, N; Milosavljević, V; Daniels, S

    2011-08-01

    In this paper we present the development and application of a real time atmospheric pressure discharge monitoring diagnostic. The software based diagnostic is designed to extract latent electrical and optical information associated with the operation of an atmospheric pressure dielectric barrier discharge (APDBD) over long time scales. Given that little is known about long term temporal effects in such discharges, the diagnostic methodology is applied to the monitoring of an APDBD in helium and helium with both 0.1% nitrogen and 0.1% oxygen gas admixtures over periods of tens of minutes. Given the large datasets associated with the experiments, it is shown that this process is much expedited through the novel application of multivariate correlations between the electrical and optical parameters of the corresponding chemistries which, in turn, facilitates comparisons between each individual chemistry also. The results of these studies show that the electrical and optical parameters of the discharge in helium and upon the addition of gas admixtures evolve over time scales far longer than the gas residence time and have been compared to current modelling works. It is envisaged that the diagnostic together with the application of multivariate correlations will be applied to rapid system identification and prototyping in both experimental and industrial APDBD systems in the future.

  5. Quantifying Differential Privacy under Temporal Correlations

    PubMed Central

    Cao, Yang; Yoshikawa, Masatoshi; Xiao, Yonghui; Xiong, Li

    2017-01-01

    Differential Privacy (DP) has received increasing attention as a rigorous privacy framework. Many existing studies employ traditional DP mechanisms (e.g., the Laplace mechanism) as primitives, which assume that the data are independent, or that adversaries do not have knowledge of the data correlations. However, continuous generated data in the real world tend to be temporally correlated, and such correlations can be acquired by adversaries. In this paper, we investigate the potential privacy loss of a traditional DP mechanism under temporal correlations in the context of continuous data release. First, we model the temporal correlations using Markov model and analyze the privacy leakage of a DP mechanism when adversaries have knowledge of such temporal correlations. Our analysis reveals that the privacy loss of a DP mechanism may accumulate and increase over time. We call it temporal privacy leakage. Second, to measure such privacy loss, we design an efficient algorithm for calculating it in polynomial time. Although the temporal privacy leakage may increase over time, we also show that its supremum may exist in some cases. Third, to bound the privacy loss, we propose mechanisms that convert any existing DP mechanism into one against temporal privacy leakage. Experiments with synthetic data confirm that our approach is efficient and effective. PMID:28883711

  6. High speed imaging for assessment of impact damage in natural fibre biocomposites

    NASA Astrophysics Data System (ADS)

    Ramakrishnan, Karthik Ram; Corn, Stephane; Le Moigne, Nicolas; Ienny, Patrick; Leger, Romain; Slangen, Pierre R.

    2017-06-01

    The use of Digital Image Correlation has been generally limited to the estimation of mechanical properties and fracture behaviour at low to moderate strain rates. High speed cameras dedicated to ballistic testing are often used to measure the initial and residual velocities of the projectile but rarely for damage assessment. The evaluation of impact damage is frequently achieved post-impact using visual inspection, ultrasonic C-scan or other NDI methods. Ultra-high speed cameras and developments in image processing have made possible the measurement of surface deformations and stresses in real time during dynamic cracking. In this paper, a method is presented to correlate the force- displacement data from the sensors to the slow motion tracking of the transient failure cracks using real-time high speed imaging. Natural fibre reinforced composites made of flax fibres and polypropylene matrix was chosen for the study. The creation of macro-cracks during the impact results in the loss of stiffness and a corresponding drop in the force history. However, optical instrumentation shows that the initiation of damage is not always evident and so the assessment of damage requires the use of a local approach. Digital Image Correlation is used to study the strain history of the composite and to identify the initiation and progression of damage. The effect of fly-speckled texture on strain measurement by image correlation is also studied. The developed method can be used for the evaluation of impact damage for different composite materials.

  7. TROP2 correlates with microvessel density and poor prognosis in hilar cholangiocarcinoma.

    PubMed

    Ning, Shanglei; Guo, Sen; Xie, Jianjun; Xu, Yunfei; Lu, Xiaofei; Chen, Yuxin

    2013-02-01

    Trophoblast cell surface antigen 2 (TROP2) was found to be associated with tumor progression and poor prognosis in a variety of epithelial carcinomas. The aim of the study was to investigate TROP2 expression and its prognostic impact in hilar cholangiocarcinoma. Immunohistochemistry and quantitative real-time PCR were used to determine TROP2 expression in surgical specimens from 70 hilar cholangiocarcinoma patients receiving radical resection. The relationship between TROP2 expression and microvessel density was investigated and standard statistical analysis was used to evaluate TROP2 prognosis significance in hilar cholangiocarcinoma. High TROP2 expression by immunohistochemistry was found in 43 (61.4 %) of the 70 tumor specimens. Quantitative real-time PCR confirmed that TROP2 level in tumor was significantly higher than in non-tumoral biliary tissues (P = 0.001). Significant correlations were found between TROP2 expression and histological differentiation (P = 0.016) and tumor T stage (P = 0.031) in hilar cholangiocarcinoma. TROP2 expression correlated with microvessel density in hilar cholangiocarcinoma (P = 0.026). High TROP2 expression patients had a significantly poorer overall survival rate than those with low TROP2 expression (30 vs. 68.5 %, P = 0.001), and multivariate Cox regression analysis indicated TROP2 as an independent prognostic factor for hilar cholangiocarcinoma (P = 0.004). TROP2 expression correlates with microvessel density significantly and is an independent prognostic factor in human hilar cholangiocarcinoma.

  8. Circulating long non-coding RNAs NRON and MHRT as novel predictive biomarkers of heart failure.

    PubMed

    Xuan, Lina; Sun, Lihua; Zhang, Ying; Huang, Yuechao; Hou, Yan; Li, Qingqi; Guo, Ying; Feng, Bingbing; Cui, Lina; Wang, Xiaoxue; Wang, Zhiguo; Tian, Ye; Yu, Bo; Wang, Shu; Xu, Chaoqian; Zhang, Mingyu; Du, Zhimin; Lu, Yanjie; Yang, Bao Feng

    2017-09-01

    This study sought to evaluate the potential of circulating long non-coding RNAs (lncRNAs) as biomarkers for heart failure (HF). We measured the circulating levels of 13 individual lncRNAs which are known to be relevant to cardiovascular disease in the plasma samples from 72 HF patients and 60 non-HF control participants using real-time reverse transcription-polymerase chain reaction (real-time RT-PCR) methods. We found that out of the 13 lncRNAs tested, non-coding repressor of NFAT (NRON) and myosin heavy-chain-associated RNA transcripts (MHRT) had significantly higher plasma levels in HF than in non-HF subjects: 3.17 ± 0.30 versus 1.0 ± 0.07 for NRON (P < 0.0001) and 1.66 ± 0.14 versus 1.0 ± 0.12 for MHRT (P < 0.0001). The area under the ROC curve was 0.865 for NRON and 0.702 for MHRT. Univariate and multivariate analyses identified NRON and MHRT as independent predictors for HF. Spearman's rank correlation analysis showed that NRON was negatively correlated with HDL and positively correlated with LDH, whereas MHRT was positively correlated with AST and LDH. Hence, elevation of circulating NRON and MHRT predicts HF and may be considered as novel biomarkers of HF. © 2017 The Authors. Journal of Cellular and Molecular Medicine published by John Wiley & Sons Ltd and Foundation for Cellular and Molecular Medicine.

  9. Real-time probabilistic covariance tracking with efficient model update.

    PubMed

    Wu, Yi; Cheng, Jian; Wang, Jinqiao; Lu, Hanqing; Wang, Jun; Ling, Haibin; Blasch, Erik; Bai, Li

    2012-05-01

    The recently proposed covariance region descriptor has been proven robust and versatile for a modest computational cost. The covariance matrix enables efficient fusion of different types of features, where the spatial and statistical properties, as well as their correlation, are characterized. The similarity between two covariance descriptors is measured on Riemannian manifolds. Based on the same metric but with a probabilistic framework, we propose a novel tracking approach on Riemannian manifolds with a novel incremental covariance tensor learning (ICTL). To address the appearance variations, ICTL incrementally learns a low-dimensional covariance tensor representation and efficiently adapts online to appearance changes of the target with only O(1) computational complexity, resulting in a real-time performance. The covariance-based representation and the ICTL are then combined with the particle filter framework to allow better handling of background clutter, as well as the temporary occlusions. We test the proposed probabilistic ICTL tracker on numerous benchmark sequences involving different types of challenges including occlusions and variations in illumination, scale, and pose. The proposed approach demonstrates excellent real-time performance, both qualitatively and quantitatively, in comparison with several previously proposed trackers.

  10. [Real-time monitoring of anti-influenza vaccination in the 65 and over population in France based on vaccine sales].

    PubMed

    Pivette, M; Auvigne, V; Guérin, P; Mueller, J E

    2017-04-01

    The aim of this study was to describe a tool based on vaccine sales to estimate vaccination coverage against seasonal influenza in near real-time in the French population aged 65 and over. Vaccine sales data available on sale-day +1 came from a stratified sample of 3004 pharmacies in metropolitan France. Vaccination coverage rates were estimated between 2009 and 2014 and compared with those obtained based on vaccination refund data from the general health insurance scheme. The seasonal vaccination coverage estimates were highly correlated with those obtained from refund data. They were also slightly higher, which can be explained by the inclusion of non-reimbursed vaccines and the consideration of all individuals aged 65 and over. We have developed an online tool that provides estimates of daily vaccination coverage during each vaccination campaign. The developed tool provides a reliable and near real-time estimation of vaccination coverage among people aged 65 and over. It can be used to evaluate and adjust public health messages. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  11. Real-time understanding of lignocellulosic bioethanol fermentation by Raman spectroscopy

    PubMed Central

    2013-01-01

    Background A substantial barrier to commercialization of lignocellulosic ethanol production is a lack of process specific sensors and associated control strategies that are essential for economic viability. Current sensors and analytical techniques require lengthy offline analysis or are easily fouled in situ. Raman spectroscopy has the potential to continuously monitor fermentation reactants and products, maximizing efficiency and allowing for improved process control. Results In this paper we show that glucose and ethanol in a lignocellulosic fermentation can be accurately monitored by a 785 nm Raman spectroscopy instrument and novel immersion probe, even in the presence of an elevated background thought to be caused by lignin-derived compounds. Chemometric techniques were used to reduce the background before generating calibration models for glucose and ethanol concentration. The models show very good correlation between the real-time Raman spectra and the offline HPLC validation. Conclusions Our results show that the changing ethanol and glucose concentrations during lignocellulosic fermentation processes can be monitored in real-time, allowing for optimization and control of large scale bioconversion processes. PMID:23425590

  12. Real-time three-dimensional color Doppler echocardiography for characterizing the spatial velocity distribution and quantifying the peak flow rate in the left ventricular outflow tract

    NASA Technical Reports Server (NTRS)

    Tsujino, H.; Jones, M.; Shiota, T.; Qin, J. X.; Greenberg, N. L.; Cardon, L. A.; Morehead, A. J.; Zetts, A. D.; Travaglini, A.; Bauer, F.; hide

    2001-01-01

    Quantification of flow with pulsed-wave Doppler assumes a "flat" velocity profile in the left ventricular outflow tract (LVOT), which observation refutes. Recent development of real-time, three-dimensional (3-D) color Doppler allows one to obtain an entire cross-sectional velocity distribution of the LVOT, which is not possible using conventional 2-D echo. In an animal experiment, the cross-sectional color Doppler images of the LVOT at peak systole were derived and digitally transferred to a computer to visualize and quantify spatial velocity distributions and peak flow rates. Markedly skewed profiles, with higher velocities toward the septum, were consistently observed. Reference peak flow rates by electromagnetic flow meter correlated well with 3-D peak flow rates (r = 0.94), but with an anticipated underestimation. Real-time 3-D color Doppler echocardiography was capable of determining cross-sectional velocity distributions and peak flow rates, demonstrating the utility of this new method for better understanding and quantifying blood flow phenomena.

  13. 25 ns software correlator for photon and fluorescence correlation spectroscopy

    NASA Astrophysics Data System (ADS)

    Magatti, Davide; Ferri, Fabio

    2003-02-01

    A 25 ns time resolution, multi-tau software correlator developed in LABVIEW based on the use of a standard photon counting unit, a fast timer/counter board (6602-PCI National Instrument) and a personal computer (PC) (1.5 GHz Pentium 4) is presented and quantitatively discussed. The correlator works by processing the stream of incoming data in parallel according to two different algorithms: For large lag times (τ⩾100 μs), a classical time-mode (TM) scheme, based on the measure of the number of pulses per time interval, is used; differently, for τ⩽100 μs a photon-mode (PM) scheme is adopted and the time sequence of the arrival times of the photon pulses is measured. By combining the two methods, we developed a system capable of working out correlation functions on line, in full real time for the TM correlator and partially in batch processing for the PM correlator. For the latter one, the duty cycle depends on the count rate of the incoming pulses, being ˜100% for count rates ⩽3×104 Hz, ˜15% at 105 Hz, and ˜1% at 106 Hz. For limitations imposed by the fairly small first-in, first-out (FIFO) buffer available on the counter board, the maximum count rate permissible for a proper functioning of the PM correlator is limited to ˜105 Hz. However, this limit can be removed by using a board with a deeper FIFO. Similarly, the 25 ns time resolution is only limited by maximum clock frequency available on the 6602-PCI and can be easily improved by using a faster clock. When tested on dilute solutions of calibrated latex spheres, the overall performances of the correlator appear to be comparable with those of commercial hardware correlators, but with several nontrivial advantages related to its flexibility, low cost, and easy adaptability to future developments of PC and data acquisition technology.

  14. Continuous, Large-Scale Processing of Seismic Archives for High-Resolution Monitoring of Seismic Activity and Seismogenic Properties

    NASA Astrophysics Data System (ADS)

    Waldhauser, F.; Schaff, D. P.

    2012-12-01

    Archives of digital seismic data recorded by seismometer networks around the world have grown tremendously over the last several decades helped by the deployment of seismic stations and their continued operation within the framework of monitoring earthquake activity and verification of the Nuclear Test-Ban Treaty. We show results from our continuing effort in developing efficient waveform cross-correlation and double-difference analysis methods for the large-scale processing of regional and global seismic archives to improve existing earthquake parameter estimates, detect seismic events with magnitudes below current detection thresholds, and improve real-time monitoring procedures. We demonstrate the performance of these algorithms as applied to the 28-year long seismic archive of the Northern California Seismic Network. The tools enable the computation of periodic updates of a high-resolution earthquake catalog of currently over 500,000 earthquakes using simultaneous double-difference inversions, achieving up to three orders of magnitude resolution improvement over existing hypocenter locations. This catalog, together with associated metadata, form the underlying relational database for a real-time double-difference scheme, DDRT, which rapidly computes high-precision correlation times and hypocenter locations of new events with respect to the background archive (http://ddrt.ldeo.columbia.edu). The DDRT system facilitates near-real-time seismicity analysis, including the ability to search at an unprecedented resolution for spatio-temporal changes in seismogenic properties. In areas with continuously recording stations, we show that a detector built around a scaled cross-correlation function can lower the detection threshold by one magnitude unit compared to the STA/LTA based detector employed at the network. This leads to increased event density, which in turn pushes the resolution capability of our location algorithms. On a global scale, we are currently building the computational framework for double-difference processing the combined parametric and waveform archives of the ISC, NEIC, and IRIS with over three million recorded earthquakes worldwide. Since our methods are scalable and run on inexpensive Beowulf clusters, periodic re-analysis of such archives may thus become a routine procedure to continuously improve resolution in existing global earthquake catalogs. Results from subduction zones and aftershock sequences of recent great earthquakes demonstrate the considerable social and economic impact that high-resolution images of active faults, when available in real-time, will have in the prompt evaluation and mitigation of seismic hazards. These results also highlight the need for consistent long-term seismic monitoring and archiving of records.

  15. Enhanced tactical radar correlator (ETRAC): true interoperability of the 1990s

    NASA Astrophysics Data System (ADS)

    Guillen, Frank J.

    1994-10-01

    The enhanced tactical radar correlator (ETRAC) system is under development at Westinghouse Electric Corporation for the Army Space Program Office (ASPO). ETRAC is a real-time synthetic aperture radar (SAR) processing system that provides tactical IMINT to the corps commander. It features an open architecture comprised of ruggedized commercial-off-the-shelf (COTS), UNIX based workstations and processors. The architecture features the DoD common SAR processor (CSP), a multisensor computing platform to accommodate a variety of current and future imaging needs. ETRAC's principal functions include: (1) Mission planning and control -- ETRAC provides mission planning and control for the U-2R and ASARS-2 sensor, including capability for auto replanning, retasking, and immediate spot. (2) Image formation -- the image formation processor (IFP) provides the CPU intensive processing capability to produce real-time imagery for all ASARS imaging modes of operation. (3) Image exploitation -- two exploitation workstations are provided for first-phase image exploitation, manipulation, and annotation. Products include INTEL reports, annotated NITF SID imagery, high resolution hard copy prints and targeting data. ETRAC is transportable via two C-130 aircraft, with autonomous drive on/off capability for high mobility. Other autonomous capabilities include rapid setup/tear down, extended stand-alone support, internal environmental control units (ECUs) and power generation. ETRAC's mission is to provide the Army field commander with accurate, reliable, and timely imagery intelligence derived from collections made by the ASARS-2 sensor, located on-board the U-2R aircraft. To accomplish this mission, ETRAC receives video phase history (VPH) directly from the U-2R aircraft and converts it in real time into soft copy imagery for immediate exploitation and dissemination to the tactical users.

  16. Direct measurement of proximal isovelocity surface area by real-time three-dimensional color Doppler for quantitation of aortic regurgitant volume: an in vitro validation.

    PubMed

    Pirat, Bahar; Little, Stephen H; Igo, Stephen R; McCulloch, Marti; Nosé, Yukihiko; Hartley, Craig J; Zoghbi, William A

    2009-03-01

    The proximal isovelocity surface area (PISA) method is useful in the quantitation of aortic regurgitation (AR). We hypothesized that actual measurement of PISA provided with real-time 3-dimensional (3D) color Doppler yields more accurate regurgitant volumes than those estimated by 2-dimensional (2D) color Doppler PISA. We developed a pulsatile flow model for AR with an imaging chamber in which interchangeable regurgitant orifices with defined shapes and areas were incorporated. An ultrasonic flow meter was used to calculate the reference regurgitant volumes. A total of 29 different flow conditions for 5 orifices with different shapes were tested at a rate of 72 beats/min. 2D PISA was calculated as 2pi r(2), and 3D PISA was measured from 8 equidistant radial planes of the 3D PISA. Regurgitant volume was derived as PISA x aliasing velocity x time velocity integral of AR/peak AR velocity. Regurgitant volumes by flow meter ranged between 12.6 and 30.6 mL/beat (mean 21.4 +/- 5.5 mL/beat). Regurgitant volumes estimated by 2D PISA correlated well with volumes measured by flow meter (r = 0.69); however, a significant underestimation was observed (y = 0.5x + 0.6). Correlation with flow meter volumes was stronger for 3D PISA-derived regurgitant volumes (r = 0.83); significantly less underestimation of regurgitant volumes was seen, with a regression line close to identity (y = 0.9x + 3.9). Direct measurement of PISA is feasible, without geometric assumptions, using real-time 3D color Doppler. Calculation of aortic regurgitant volumes with 3D color Doppler using this methodology is more accurate than conventional 2D method with hemispheric PISA assumption.

  17. Strain measurement of abdominal aortic aneurysm with real-time 3D ultrasound speckle tracking.

    PubMed

    Bihari, P; Shelke, A; Nwe, T H; Mularczyk, M; Nelson, K; Schmandra, T; Knez, P; Schmitz-Rixen, T

    2013-04-01

    Abdominal aortic aneurysm rupture is caused by mechanical vascular tissue failure. Although mechanical properties within the aneurysm vary, currently available ultrasound methods assess only one cross-sectional segment of the aorta. This study aims to establish real-time 3-dimensional (3D) speckle tracking ultrasound to explore local displacement and strain parameters of the whole abdominal aortic aneurysm. Validation was performed on a silicone aneurysm model, perfused in a pulsatile artificial circulatory system. Wall motion of the silicone model was measured simultaneously with a commercial real-time 3D speckle tracking ultrasound system and either with laser-scan micrometry or with video photogrammetry. After validation, 3D ultrasound data were collected from abdominal aortic aneurysms of five patients and displacement and strain parameters were analysed. Displacement parameters measured in vitro by 3D ultrasound and laser scan micrometer or video analysis were significantly correlated at pulse pressures between 40 and 80 mmHg. Strong local differences in displacement and strain were identified within the aortic aneurysms of patients. Local wall strain of the whole abdominal aortic aneurysm can be analysed in vivo with real-time 3D ultrasound speckle tracking imaging, offering the prospect of individual non-invasive rupture risk analysis of abdominal aortic aneurysms. Copyright © 2013 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  18. Development of a real time bistatic radar receiver using signals of opportunity

    NASA Astrophysics Data System (ADS)

    Rainville, Nicholas

    Passive bistatic radar remote sensing offers a novel method of monitoring the Earth's surface by observing reflected signals of opportunity. The Global Positioning System (GPS) has been used as a source of signals for these observations and the scattering properties of GPS signals from rough surfaces are well understood. Recent work has extended GPS signal reflection observations and scattering models to include communications signals such as XM radio signals. However the communication signal reflectometry experiments to date have relied on collecting raw, high data-rate signals which are then post-processed after the end of the experiment. This thesis describes the development of a communication signal bistatic radar receiver which computes a real time correlation waveform, which can be used to retrieve measurements of the Earth's surface. The real time bistatic receiver greatly reduces the quantity of data that must be stored to perform the remote sensing measurements, as well as offering immediate feedback. This expands the applications for the receiver to include space and bandwidth limited platforms such as aircraft and satellites. It also makes possible the adjustment of flight plans to the observed conditions. This real time receiver required the development of an FGPA based signal processor, along with the integration of commercial Satellite Digital Audio Radio System (SDARS) components. The resulting device was tested both in a lab environment as well on NOAA WP-3D and NASA WB-57 aircraft.

  19. Development of a real-time PCR assay for Penicillium expansum quantification and patulin estimation in apples.

    PubMed

    Tannous, Joanna; Atoui, Ali; El Khoury, André; Kantar, Sally; Chdid, Nader; Oswald, Isabelle P; Puel, Olivier; Lteif, Roger

    2015-09-01

    Due to the occurrence and spread of the fungal contaminants in food and the difficulties to remove their resulting mycotoxins, rapid and accurate methods are needed for early detection of these mycotoxigenic fungi. The polymerase chain reaction and the real time PCR have been widely used for this purpose. Apples are suitable substrates for fungal colonization mostly caused by Penicillium expansum, which produces the mycotoxin patulin during fruit infection. This study describes the development of a real-time PCR assay incorporating an internal amplification control (IAC) to specifically detect and quantify P. expansum. A specific primer pair was designed from the patF gene, involved in patulin biosynthesis. The selected primer set showed a high specificity for P. expansum and was successfully employed in a standardized real-time PCR for the direct quantification of this fungus in apples. Using the developed system, twenty eight apples were analyzed for their DNA content. Apples were also analyzed for patulin content by HPLC. Interestingly, a positive correlation (R(2) = 0.701) was found between P. expansum DNA content and patulin concentration. This work offers an alternative to conventional methods of patulin quantification and mycological detection of P. expansum and could be very useful for the screening of patulin in fruits through the application of industrial quality control. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Subdecoherence time generation and detection of orbital entanglement in quantum dots.

    PubMed

    Brange, F; Malkoc, O; Samuelsson, P

    2015-05-01

    Recent experiments have demonstrated subdecoherence time control of individual single-electron orbital qubits. Here we propose a quantum-dot-based scheme for generation and detection of pairs of orbitally entangled electrons on a time scale much shorter than the decoherence time. The electrons are entangled, via two-particle interference, and transferred to the detectors during a single cotunneling event, making the scheme insensitive to charge noise. For sufficiently long detector dot lifetimes, cross-correlation detection of the dot charges can be performed with real-time counting techniques, providing for an unambiguous short-time Bell inequality test of orbital entanglement.

  1. Change blindness, aging, and cognition

    PubMed Central

    Rizzo, Matthew; Sparks, JonDavid; McEvoy, Sean; Viamonte, Sarah; Kellison, Ida; Vecera, Shaun P.

    2011-01-01

    Change blindness (CB), the inability to detect changes in visual scenes, may increase with age and early Alzheimer’s disease (AD). To test this hypothesis, participants were asked to localize changes in natural scenes. Dependent measures were response time (RT), hit rate, false positives (FP), and true sensitivity (d′). Increased age correlated with increased sensitivity and RT; AD predicted even slower RT. Accuracy and RT were negatively correlated. Differences in FP were nonsignificant. CB correlated with impaired attention, working memory, and executive function. Advanced age and AD were associated with increased CB, perhaps due to declining memory and attention. CB could affect real-world tasks, like automobile driving. PMID:19051127

  2. Change blindness, aging, and cognition.

    PubMed

    Rizzo, Matthew; Sparks, Jondavid; McEvoy, Sean; Viamonte, Sarah; Kellison, Ida; Vecera, Shaun P

    2009-02-01

    Change blindness (CB), the inability to detect changes in visual scenes, may increase with age and early Alzheimer's disease (AD). To test this hypothesis, participants were asked to localize changes in natural scenes. Dependent measures were response time (RT), hit rate, false positives (FP), and true sensitivity (d'). Increased age correlated with increased sensitivity and RT; AD predicted even slower RT. Accuracy and RT were negatively correlated. Differences in FP were nonsignificant. CB correlated with impaired attention, working memory, and executive function. Advanced age and AD were associated with increased CB, perhaps due to declining memory and attention. CB could affect real-world tasks, like automobile driving.

  3. Communication: a density functional with accurate fractional-charge and fractional-spin behaviour for s-electrons.

    PubMed

    Johnson, Erin R; Contreras-García, Julia

    2011-08-28

    We develop a new density-functional approach combining physical insight from chemical structure with treatment of multi-reference character by real-space modeling of the exchange-correlation hole. We are able to recover, for the first time, correct fractional-charge and fractional-spin behaviour for atoms of groups 1 and 2. Based on Becke's non-dynamical correlation functional [A. D. Becke, J. Chem. Phys. 119, 2972 (2003)] and explicitly accounting for core-valence separation and pairing effects, this method is able to accurately describe dissociation and strong correlation in s-shell many-electron systems. © 2011 American Institute of Physics

  4. Evaluation of an antigen-capture EIA for the diagnosis of hepatitis E virus infection.

    PubMed

    Zhao, C; Geng, Y; Harrison, T J; Huang, W; Song, A; Wang, Y

    2015-11-01

    An enzyme immunoassay (EIA) has been developed for hepatitis E virus (HEV) antigen (HEV-Ag) detection and marketed in China. This study aimed to evaluate the sensitivity of the assay and assess the value of HEV-Ag detection in the diagnosis of HEV infection in comparison with HEV RNA detection. Using serial dilutions of a genotype 4 HEV strain, significant correlation was found between the EIA (S/CO) and HEV RNA (IU/mL) concentration in the range 10(3.5) to 10(0.5) IU/mL HEV RNA, the Pearson correlation coefficient r approached 0.97. The EIA detection limit was 54.6 IU/mL, compared to 24 IU/mL for HEV RNA using real-time RT-PCR. In clinical samples from hepatitis E patients, the HEV-Ag and HEV RNA positivity rates were 55.6% (65/117) and 60.7% (71/117) in sera and 76.7% (56/73) and 84.9% (62/73) in stools, and the concordance of these two markers was 77.8% in sera and 80.8% in stools. In serum samples, the HEV-Ag positivity rate and the concordance between HEV-Ag and HEV RNA were inversely proportional to the presence of anti-HEV antibody. The presence of anti-HEV IgG could reduce the S/CO of the HEV-Ag EIA. These results reveal a significant correlation between the detection of HEV-Ag and HEV RNA. The sensitivity of the HEV-Ag EIA was lower than real-time RT-PCR but could be higher than conventional nested RT-PCR. Therefore, the detection of HEV-Ag in serum and faeces is valuable for the diagnosis and prognosis of HEV infection in developing regions where real-time RT-PCR is not available. © 2015 John Wiley & Sons Ltd.

  5. Use of the Microsoft Kinect system to characterize balance ability during balance training.

    PubMed

    Lim, Dohyung; Kim, ChoongYeon; Jung, HoHyun; Jung, Dukyoung; Chun, Keyoung Jin

    2015-01-01

    The risk of falling increases significantly in the elderly because of deterioration of the neural musculature regulatory mechanisms. Several studies have investigated methods of preventing falling using real-time systems to evaluate balance; however, it is difficult to monitor the results of such characterizations in real time. Herein, we describe the use of Microsoft's Kinect depth sensor system to evaluate balance in real time. Six healthy male adults (25.5±1.8 years, 173.9±6.4 cm, 71.4±6.5 kg, and 23.6±2.4 kg/m(2)), with normal balance abilities and with no musculoskeletal disorders, were selected to participate in the experiment. Movements of the participants were induced by controlling the base plane of the balance training equipment in various directions. The dynamic motion of the subjects was measured using two Kinect depth sensor systems and a three-dimensional motion capture system with eight infrared cameras. The two systems yielded similar results for changes in the center of body mass (P>0.05) with a large Pearson's correlation coefficient of γ>0.60. The results for the two systems showed similarity in the mean lower-limb joint angle with flexion-extension movements, and these values were highly correlated (hip joint: within approximately 4.6°; knee joint: within approximately 8.4°) (0.40<γ<0.74) (P>0.05). Large differences with a low correlation were, however, observed for the lower-limb joint angle in relation to abduction-adduction and internal-external rotation motion (γ<0.40) (P<0.05). These findings show that clinical and dynamic accuracy can be achieved using the Kinect system in balance training by measuring changes in the center of body mass and flexion-extension movements of the lower limbs, but not abduction-adduction and internal-external rotation.

  6. 64Cu-DOTATATE PET/MRI for Detection of Activated Macrophages in Carotid Atherosclerotic Plaques: Studies in Patients Undergoing Endarterectomy.

    PubMed

    Pedersen, Sune Folke; Sandholt, Benjamin Vikjær; Keller, Sune Høgild; Hansen, Adam Espe; Clemmensen, Andreas Ettrup; Sillesen, Henrik; Højgaard, Liselotte; Ripa, Rasmus Sejersten; Kjær, Andreas

    2015-07-01

    A feature of vulnerable atherosclerotic plaques of the carotid artery is high activity and abundance of lesion macrophages. There is consensus that this is of importance for plaque vulnerability, which may lead to clinical events, such as stroke and transient ischemic attack. We used positron emission tomography (PET) and the novel PET ligand [(64)Cu] [1,4,7,10-tetraazacyclododecane-N,N',N″,N‴-tetraacetic acid]-d-Phe1,Tyr3-octreotate ((64)Cu-DOTATATE) to specifically target macrophages via the somatostatin receptor subtype-2 in vivo. Ten patients underwent simultaneous PET/MRI to measure (64)Cu-DOTATATE uptake in carotid artery plaques before carotid endarterectomy. (64)Cu-DOTATATE uptake was significantly higher in symptomatic plaque versus the contralateral carotid artery (P<0.001). Subsequently, a total of 62 plaque segments were assessed for gene expression of selected markers of plaque vulnerability using real-time quantitative polymerase chain reaction. These results were compared with in vivo (64)Cu-DOTATATE uptake calculated as the mean standardized uptake value. Univariate analysis of real-time quantitative polymerase chain reaction and PET showed that cluster of differentiation 163 (CD163) and CD68 gene expression correlated significantly but weakly with mean standardized uptake value in scans performed 85 minutes post injection (P<0.001 and P=0.015, respectively). Subsequent multivariate analysis showed that CD163 correlated independently with (64)Cu-DOTATATE uptake (P=0.031) whereas CD68 did not contribute significantly to the final model. The novel PET tracer (64)Cu-DOTATATE accumulates in atherosclerotic plaques of the carotid artery. CD163 gene expression correlated independently with (64)Cu-DOTATATE uptake measured by real-time quantitative polymerase chain reaction in the final multivariate model, indicating that (64)Cu-DOTATATE PET is detecting alternatively activated macrophages. This association could potentially improve noninvasive identification and characterization of vulnerable plaques. © 2015 The Authors.

  7. Sound stream segregation: a neuromorphic approach to solve the “cocktail party problem” in real-time

    PubMed Central

    Thakur, Chetan Singh; Wang, Runchun M.; Afshar, Saeed; Hamilton, Tara J.; Tapson, Jonathan C.; Shamma, Shihab A.; van Schaik, André

    2015-01-01

    The human auditory system has the ability to segregate complex auditory scenes into a foreground component and a background, allowing us to listen to specific speech sounds from a mixture of sounds. Selective attention plays a crucial role in this process, colloquially known as the “cocktail party effect.” It has not been possible to build a machine that can emulate this human ability in real-time. Here, we have developed a framework for the implementation of a neuromorphic sound segregation algorithm in a Field Programmable Gate Array (FPGA). This algorithm is based on the principles of temporal coherence and uses an attention signal to separate a target sound stream from background noise. Temporal coherence implies that auditory features belonging to the same sound source are coherently modulated and evoke highly correlated neural response patterns. The basis for this form of sound segregation is that responses from pairs of channels that are strongly positively correlated belong to the same stream, while channels that are uncorrelated or anti-correlated belong to different streams. In our framework, we have used a neuromorphic cochlea as a frontend sound analyser to extract spatial information of the sound input, which then passes through band pass filters that extract the sound envelope at various modulation rates. Further stages include feature extraction and mask generation, which is finally used to reconstruct the targeted sound. Using sample tonal and speech mixtures, we show that our FPGA architecture is able to segregate sound sources in real-time. The accuracy of segregation is indicated by the high signal-to-noise ratio (SNR) of the segregated stream (90, 77, and 55 dB for simple tone, complex tone, and speech, respectively) as compared to the SNR of the mixture waveform (0 dB). This system may be easily extended for the segregation of complex speech signals, and may thus find various applications in electronic devices such as for sound segregation and speech recognition. PMID:26388721

  8. Sound stream segregation: a neuromorphic approach to solve the "cocktail party problem" in real-time.

    PubMed

    Thakur, Chetan Singh; Wang, Runchun M; Afshar, Saeed; Hamilton, Tara J; Tapson, Jonathan C; Shamma, Shihab A; van Schaik, André

    2015-01-01

    The human auditory system has the ability to segregate complex auditory scenes into a foreground component and a background, allowing us to listen to specific speech sounds from a mixture of sounds. Selective attention plays a crucial role in this process, colloquially known as the "cocktail party effect." It has not been possible to build a machine that can emulate this human ability in real-time. Here, we have developed a framework for the implementation of a neuromorphic sound segregation algorithm in a Field Programmable Gate Array (FPGA). This algorithm is based on the principles of temporal coherence and uses an attention signal to separate a target sound stream from background noise. Temporal coherence implies that auditory features belonging to the same sound source are coherently modulated and evoke highly correlated neural response patterns. The basis for this form of sound segregation is that responses from pairs of channels that are strongly positively correlated belong to the same stream, while channels that are uncorrelated or anti-correlated belong to different streams. In our framework, we have used a neuromorphic cochlea as a frontend sound analyser to extract spatial information of the sound input, which then passes through band pass filters that extract the sound envelope at various modulation rates. Further stages include feature extraction and mask generation, which is finally used to reconstruct the targeted sound. Using sample tonal and speech mixtures, we show that our FPGA architecture is able to segregate sound sources in real-time. The accuracy of segregation is indicated by the high signal-to-noise ratio (SNR) of the segregated stream (90, 77, and 55 dB for simple tone, complex tone, and speech, respectively) as compared to the SNR of the mixture waveform (0 dB). This system may be easily extended for the segregation of complex speech signals, and may thus find various applications in electronic devices such as for sound segregation and speech recognition.

  9. Design and implementation of low complexity wake-up receiver for underwater acoustic sensor networks

    NASA Astrophysics Data System (ADS)

    Yue, Ming

    This thesis designs a low-complexity dual Pseudorandom Noise (PN) scheme for identity (ID) detection and coarse frame synchronization. The two PN sequences for a node are identical and are separated by a specified length of gap which serves as the ID of different sensor nodes. The dual PN sequences are short in length but are capable of combating severe underwater acoustic (UWA) multipath fading channels that exhibit time varying impulse responses up to 100 taps. The receiver ID detection is implemented on a microcontroller MSP430F5529 by calculating the correlation between the two segments of the PN sequence with the specified separation gap. When the gap length is matched, the correlator outputs a peak which triggers the wake-up enable. The time index of the correlator peak is used as the coarse synchronization of the data frame. The correlator is implemented by an iterative algorithm that uses only one multiplication and two additions for each sample input regardless of the length of the PN sequence, thus achieving low computational complexity. The real-time processing requirement is also met via direct memory access (DMA) and two circular buffers to accelerate data transfer between the peripherals and the memory. The proposed dual PN detection scheme has been successfully tested by simulated fading channels and real-world measured channels. The results show that, in long multipath channels with more than 60 taps, the proposed scheme achieves high detection rate and low false alarm rate using maximal-length sequences as short as 31 bits to 127 bits, therefore it is suitable as a low-power wake-up receiver. The future research will integrate the wake-up receiver with Digital Signal Processors (DSP) for payload detection.

  10. Evaluation of conventional and alternative monitoring methods for a recreational marine beach with nonpoint source of fecal contamination.

    PubMed

    Shibata, Tomoyuki; Solo-Gabriele, Helena M; Sinigalliano, Christopher D; Gidley, Maribeth L; Plano, Lisa R W; Fleisher, Jay M; Wang, John D; Elmir, Samir M; He, Guoqing; Wright, Mary E; Abdelzaher, Amir M; Ortega, Cristina; Wanless, David; Garza, Anna C; Kish, Jonathan; Scott, Troy; Hollenbeck, Julie; Backer, Lorraine C; Fleming, Lora E

    2010-11-01

    The objectives of this work were to compare enterococci (ENT) measurements based on the membrane filter, ENT(MF) with alternatives that can provide faster results including alternative enterococci methods (e.g., chromogenic substrate (CS), and quantitative polymerase chain reaction (qPCR)), and results from regression models based upon environmental parameters that can be measured in real-time. ENT(MF) were also compared to source tracking markers (Staphylococcus aureus, Bacteroidales human and dog markers, and Catellicoccus gull marker) in an effort to interpret the variability of the signal. Results showed that concentrations of enterococci based upon MF (<2 to 3320 CFU/100 mL) were significantly different from the CS and qPCR methods (p < 0.01). The correlations between MF and CS (r = 0.58, p < 0.01) were stronger than between MF and qPCR (r ≤ 0.36, p < 0.01). Enterococci levels by MF, CS, and qPCR methods were positively correlated with turbidity and tidal height. Enterococci by MF and CS were also inversely correlated with solar radiation but enterococci by qPCR was not. The regression model based on environmental variables provided fair qualitative predictions of enterococci by MF in real-time, for daily geometric mean levels, but not for individual samples. Overall, ENT(MF) was not significantly correlated with source tracking markers with the exception of samples collected during one storm event. The inability of the regression model to predict ENT(MF) levels for individual samples is likely due to the different sources of ENT impacting the beach at any given time, making it particularly difficult to to predict short-term variability of ENT(MF) for environmental parameters.

  11. Self-consistent DFT +U method for real-space time-dependent density functional theory calculations

    NASA Astrophysics Data System (ADS)

    Tancogne-Dejean, Nicolas; Oliveira, Micael J. T.; Rubio, Angel

    2017-12-01

    We implemented various DFT+U schemes, including the Agapito, Curtarolo, and Buongiorno Nardelli functional (ACBN0) self-consistent density-functional version of the DFT +U method [Phys. Rev. X 5, 011006 (2015), 10.1103/PhysRevX.5.011006] within the massively parallel real-space time-dependent density functional theory (TDDFT) code octopus. We further extended the method to the case of the calculation of response functions with real-time TDDFT+U and to the description of noncollinear spin systems. The implementation is tested by investigating the ground-state and optical properties of various transition-metal oxides, bulk topological insulators, and molecules. Our results are found to be in good agreement with previously published results for both the electronic band structure and structural properties. The self-consistent calculated values of U and J are also in good agreement with the values commonly used in the literature. We found that the time-dependent extension of the self-consistent DFT+U method yields improved optical properties when compared to the empirical TDDFT+U scheme. This work thus opens a different theoretical framework to address the nonequilibrium properties of correlated systems.

  12. Development of an Efficient Binaural Simulation for the Analysis of Structural Acoustic Data

    NASA Technical Reports Server (NTRS)

    Johnson, Marty E.; Lalime, Aimee L.; Grosveld, Ferdinand W.; Rizzi, Stephen A.; Sullivan, Brenda M.

    2003-01-01

    Applying binaural simulation techniques to structural acoustic data can be very computationally intensive as the number of discrete noise sources can be very large. Typically, Head Related Transfer Functions (HRTFs) are used to individually filter the signals from each of the sources in the acoustic field. Therefore, creating a binaural simulation implies the use of potentially hundreds of real time filters. This paper details two methods of reducing the number of real-time computations required by: (i) using the singular value decomposition (SVD) to reduce the complexity of the HRTFs by breaking them into dominant singular values and vectors and (ii) by using equivalent source reduction (ESR) to reduce the number of sources to be analyzed in real-time by replacing sources on the scale of a structural wavelength with sources on the scale of an acoustic wavelength. The ESR and SVD reduction methods can be combined to provide an estimated computation time reduction of 99.4% for the structural acoustic data tested. In addition, preliminary tests have shown that there is a 97% correlation between the results of the combined reduction methods and the results found with the current binaural simulation techniques

  13. Optical joint correlator for real-time image tracking and retinal surgery

    NASA Technical Reports Server (NTRS)

    Juday, Richard D. (Inventor)

    1991-01-01

    A method for tracking an object in a sequence of images is described. Such sequence of images may, for example, be a sequence of television frames. The object in the current frame is correlated with the object in the previous frame to obtain the relative location of the object in the two frames. An optical joint transform correlator apparatus is provided to carry out the process. Such joint transform correlator apparatus forms the basis for laser eye surgical apparatus where an image of the fundus of an eyeball is stabilized and forms the basis for the correlator apparatus to track the position of the eyeball caused by involuntary movement. With knowledge of the eyeball position, a surgical laser can be precisely pointed toward a position on the retina.

  14. ICA-Derived EEG Correlates to Mental Fatigue, Effort, and Workload in a Realistically Simulated Air Traffic Control Task.

    PubMed

    Dasari, Deepika; Shou, Guofa; Ding, Lei

    2017-01-01

    Electroencephalograph (EEG) has been increasingly studied to identify distinct mental factors when persons perform cognitively demanding tasks. However, most of these studies examined EEG correlates at channel domain, which suffers the limitation that EEG signals are the mixture of multiple underlying neuronal sources due to the volume conduction effect. Moreover, few studies have been conducted in real-world tasks. To precisely probe EEG correlates with specific neural substrates to mental factors in real-world tasks, the present study examined EEG correlates to three mental factors, i.e., mental fatigue [also known as time-on-task (TOT) effect], workload and effort, in EEG component signals, which were obtained using an independent component analysis (ICA) on high-density EEG data. EEG data were recorded when subjects performed a realistically simulated air traffic control (ATC) task for 2 h. Five EEG independent component (IC) signals that were associated with specific neural substrates (i.e., the frontal, central medial, motor, parietal, occipital areas) were identified. Their spectral powers at their corresponding dominant bands, i.e., the theta power of the frontal IC and the alpha power of the other four ICs, were detected to be correlated to mental workload and effort levels, measured by behavioral metrics. Meanwhile, a linear regression analysis indicated that spectral powers at five ICs significantly increased with TOT. These findings indicated that different levels of mental factors can be sensitively reflected in EEG signals associated with various brain functions, including visual perception, cognitive processing, and motor outputs, in real-world tasks. These results can potentially aid in the development of efficient operational interfaces to ensure productivity and safety in ATC and beyond.

  15. Adaptive Liquid Crystal TV Based Joint Transform Correlator as Applied to Real-Time Pattern Recognition

    DTIC Science & Technology

    1991-05-23

    rotational objects can b ec-tetd. E-Ac Ceedent 3exp-erimental demon ct r-ati ons for these tuo zethodsc hare L-en nerfor-med.A aner atohi naturve xs...dependent nature ---f the Joint rransifore f.Iter. Unlike theVa.dr %g~ii ssignal indepndent. a0. eir -las 3advata in real-tim ’-n14-a-entatio-n...a-tit reI ra-’ t --er is n -) 0 s-’ow Uha thsthoesc~-heo 8 spectral content of the target. A paper of this nature is published in the Optics and

  16. Development of VIS/NIR spectroscopic system for real-time prediction of fresh pork quality

    NASA Astrophysics Data System (ADS)

    Zhang, Haiyun; Peng, Yankun; Zhao, Songwei; Sasao, Akira

    2013-05-01

    Quality attributes of fresh meat will influence nutritional value and consumers' purchasing power. The aim of the research was to develop a prototype for real-time detection of quality in meat. It consisted of hardware system and software system. A VIS/NIR spectrograph in the range of 350 to 1100 nm was used to collect the spectral data. In order to acquire more potential information of the sample, optical fiber multiplexer was used. A conveyable and cylindrical device was designed and fabricated to hold optical fibers from multiplexer. High power halogen tungsten lamp was collected as the light source. The spectral data were obtained with the exposure time of 2.17ms from the surface of the sample by press down the trigger switch on the self-developed system. The system could automatically acquire, process, display and save the data. Moreover the quality could be predicted on-line. A total of 55 fresh pork samples were used to develop prediction model for real time detection. The spectral data were pretreated with standard normalized variant (SNV) and partial least squares regression (PLSR) was used to develop prediction model. The correlation coefficient and root mean square error of the validation set for water content and pH were 0.810, 0.653, and 0.803, 0.098 respectively. The research shows that the real-time non-destructive detection system based on VIS/NIR spectroscopy can be efficient to predict the quality of fresh meat.

  17. Dopant-assisted negative photoionization Ion mobility spectrometry coupled with on-line cooling inlet for real-time monitoring H2S concentration in sewer gas.

    PubMed

    Peng, Liying; Jiang, Dandan; Wang, Zhenxin; Hua, Lei; Li, Haiyang

    2016-06-01

    Malodorous hydrogen sulfide (H2S) gas often exists in the sewer system and associates with the problems of releasing the dangerous odor to the atmosphere and causing sewer pipe to be corroded. A simple method is in demand for real-time measuring H2S level in the sewer gas. In this paper, an innovated method based on dopant-assisted negative photoionization ion mobility spectrometry (DANP-IMS) with on-line semiconductor cooling inlet was put forward and successfully applied for the real-time measurement of H2S in sewer gas. The influence of moisture was effectively reduced via an on-line cooling method and a non-equilibrium dilution with drift gas. The limits of quantitation for the H2S in ≥60% relative humidity air could be obtained at ≤79.0ng L(-1) with linear ranges of 129-2064ng L(-1). The H2S concentration in a sewer manhole was successfully determined while its product ions were identified by an ion-mobility time-of-fight mass spectrometry. Finally, the correlation between sewer H2S concentration and the daily routines and habits of residents was investigated through hourly or real-time monitoring the variation of sewer H2S in manholes, indicating the power of this DANP-IMS method in assessing the H2S concentration in sewer system. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. [Methods Used for Monitoring Cure Reactions in Real-time in an Autoclave

    NASA Technical Reports Server (NTRS)

    Cooper, John B.; Wise, Kent L.; Jensen, Brian J. (Technical Monitor)

    2000-01-01

    The goal of the research was to investigate methods for monitoring cure reactions in real-time in an autoclave. This is of particular importance to NASA Langley Research Center because polyimides were proposed for use in the High Speed Civil Transport (HSCT) program. Understanding the cure chemistry behind the polyimides would allow for intelligent processing of the composites made from their use. This work has led to two publications in peer-reviewed journals and a patent. The journal articles are listed as Appendix A which is on the instrument design of the research and Appendix B which is on the cure chemistry. Also, a patent has been awarded for the instrumental design developed under this grant which is given as Appendix C. There has been a significant amount of research directed at developing methods for monitoring cure reactions in real-time within the autoclave. The various research efforts can be categorized as methods providing either direct chemical bonding information or methods that provide indirect chemical bonding information. Methods falling into the latter category are fluorescence, dielectric loss, ultrasonic and similar type methods. Correlation of such measurements with the underlying chemistry is often quite difficult since these techniques do not allow monitoring of the curing chemistry which is ultimately responsible for material properties. Direct methods such as vibrational spectroscopy, however, can often be easily correlated with the underlying chemistry of a reaction. Such methods include Raman spectroscopy, mid-IR absorbance, and near-IR absorbance. With the recent advances in fiber-optics, these spectroscopic techniques can be applied to remote on-line monitoring.

  19. Alteration of functional connectivity during real-time fMRI regulation of PCC

    NASA Astrophysics Data System (ADS)

    Zhang, Gaoyan; Yao, Li; Long, Zhiying

    2012-03-01

    Real-time functional magnetic resonance imaging (rtfMRI) can be used to train the subjects to selectively control activity of specific brain area so as to affect the activation in the target region and even to improve cognition and behavior. So far, whether brain activity in posterior cingulate cortex (PCC) can be regulated by rtfMRI has not been reported. In the present study, we aimed at investigating whether real-time regulation of activity in PCC can change the functional connectivity between PCC and other brain regions. A total of 12 subjects underwent two training runs, each lasts 782s. During the training, subjects were instructed to down regulate activity in PCC by imagining right hand finger movement with the sequence of 4-2-3-1-3-4-2 during task and relax as possible as they can during rest. To control for any effects induced by repeated practice, another 12 subjects in the control group received the same experiment procedure and instruction except with no feedback during training. Experiment results show that increased functional connectivity of PCC with medial frontal cortex (MFC) was observed in both groups during the two training runs. However, PCC of the experimental group is correlated with larger areas in MFC than the control group. Because the positive correlation between task performance and MFC to PCC connectivity has been demonstrated previously, we infer that the stronger connectivity between PCC and MFC in the experimental group may suggest that the experimental group with neurofeedback can more efficiently regulate PCC than the control group without neurofeedback.

  20. Real-time surrogate analysis for potential oil and gas contamination of drinking water resources

    NASA Astrophysics Data System (ADS)

    Son, Ji-Hee; Carlson, Kenneth H.

    2015-09-01

    Public concerns related to the fast-growing shale oil and gas industry have increased during recent years. The major concern regarding shale gas production is the potential of fracturing fluids being injected into the well or produced fluids flowing out of the well to contaminate drinking water resources such as surface water and groundwater. Fracturing fluids contain high total dissolved solids (TDS); thus, changes in TDS concentrations in groundwater might indicate influences of fracturing fluids. An increase of methane concentrations in groundwater could also potentially be due to hydraulic fracturing activities. To understand the possible contamination of groundwater by fracturing activities, real-time groundwater monitoring is being implemented in the Denver-Julesburg basin of northeast Colorado. A strategy of monitoring of surrogate parameters was chosen instead of measuring potential contaminants directly, an approach that is not cost effective or operationally practical. Contaminant surrogates of TDS and dissolved methane were proposed in this study, and were tested for correlation and data distribution with laboratory experiments. Correlations between TDS and electrical conductivity (EC), and between methane contamination and oxidation-reduction potential (ORP) were strong at low concentrations of contaminants (1 mg/L TDS and 0.3 mg/L CH4). Dissolved oxygen (DO) was only an effective surrogate at higher methane concentrations (≥2.5 mg/L). The results indicated that EC and ORP are effective surrogates for detecting concentration changes of TDS and methane, respectively, and that a strategy of monitoring for easy to measure parameters can be effective detecting real-time, anomalous behavior relative to a predetermined baseline.

Top