Bite Force Recording Devices - A Review
Kumathalli, Kanteshwari Iranagouda; Jain, Vinay; Kumar, Rajesh
2017-01-01
In dental research, bite force serves as a valuable parameter to evaluate the efficacy of masticatory system. A variety of devices with different design and working principle have been used to record bite force, but no single device is capable to record all the required forces. One may find it difficult to choose a device that will fulfil the purpose of recording bite force for research. So, the present review aims to report and compare the wide range of devices and will help in describing their uses for recording bite force. PMID:29207848
Motor unit size estimation: confrontation of surface EMG with macro EMG.
Roeleveld, K; Stegeman, D F; Falck, B; Stålberg, E V
1997-06-01
Surface EMG (SEMG) is little used for diagnostic purposes in clinical neurophysiology, mainly because it provides little direct information on individual motor units (MUs). One of the techniques to estimate the MU size is intra-muscular Macro EMG. The present study compares SEMG with Macro EMG. Fifty-eight channel SEMG was recorded simultaneously with Macro EMG. Individual MUPs were obtained by single fiber triggered averaging. All recordings were made from the biceps brachii of healthy subjects during voluntary contraction at low force. High positive correlations were found between all Macro and Surface motor unit potential (MUP) parameters: area, peak-to-peak amplitude, negative peak amplitude and positive peak amplitude. The MUPs recorded with SEMG were dependent on the distance between the MU and the skin surface. Normalizing the SEMG parameters for MU location did not improve the correlation coefficient between the parameters of both techniques. The two measurement techniques had almost the same relative range in MUP parameters in any individual subject compared to the others, especially after normalizing the surface MUP parameters for MU location. MUPs recorded with this type of SEMG provide useful information about the MU size.
Haering, Diane; Huchez, Aurore; Barbier, Franck; Holvoët, Patrice; Begon, Mickaël
2017-01-01
Introduction Teaching acrobatic skills with a minimal amount of repetition is a major challenge for coaches. Biomechanical, statistical or computer simulation tools can help them identify the most determinant factors of performance. Release parameters, change in moment of inertia and segmental momentum transfers were identified in the prediction of acrobatics success. The purpose of the present study was to evaluate the relative contribution of these parameters in performance throughout expertise or optimisation based improvements. The counter movement forward in flight (CMFIF) was chosen for its intrinsic dichotomy between the accessibility of its attempt and complexity of its mastery. Methods Three repetitions of the CMFIF performed by eight novice and eight advanced female gymnasts were recorded using a motion capture system. Optimal aerial techniques that maximise rotation potential at regrasp were also computed. A 14-segment-multibody-model defined through the Rigid Body Dynamics Library was used to compute recorded and optimal kinematics, and biomechanical parameters. A stepwise multiple linear regression was used to determine the relative contribution of these parameters in novice recorded, novice optimised, advanced recorded and advanced optimised trials. Finally, fixed effects of expertise and optimisation were tested through a mixed-effects analysis. Results and discussion Variation in release state only contributed to performances in novice recorded trials. Moment of inertia contribution to performance increased from novice recorded, to novice optimised, advanced recorded, and advanced optimised trials. Contribution to performance of momentum transfer to the trunk during the flight prevailed in all recorded trials. Although optimisation decreased transfer contribution, momentum transfer to the arms appeared. Conclusion Findings suggest that novices should be coached on both contact and aerial technique. Inversely, mainly improved aerial technique helped advanced gymnasts increase their performance. For both, reduction of the moment of inertia should be focused on. The method proposed in this article could be generalized to any aerial skill learning investigation. PMID:28422954
Bruna, Ondřej; Levora, Tomáš; Holub, Jan
2018-05-08
Pilots of ultra light aircraft have limited training resources, but with the use of low cost simulators it might be possible to train and test some parts of their training on the ground. The purpose of this paper is to examine possibility of stress inducement on a low cost flight simulator. Stress is assessed from electrocardiogram and respiration. Engine failure during flight served as a stress inducement stimuli. For one flight, pilots had access to an emergency navigation system. There were recorded some statistically significant changes in parameters regarding breathing frequency. Although no significant change was observed in ECG parameters, there appears to be an effect on respiration parameters. Physiological signals processed with analysis of variance suggest, that the moment of engine failure and approach for landing affected average breathing frequency. Presence of navigation interface does not appear to have a significant effect on pilots.
40 CFR 98.195 - Procedures for estimating missing data.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 21 2014-07-01 2014-07-01 false Procedures for estimating missing data... estimating missing data. For the procedure in § 98.193(b)(1), a complete record of all measured parameters... all available process data or data used for accounting purposes. (b) For missing values related to the...
NASA Astrophysics Data System (ADS)
Jelinek, Herbert F.; Pham, Phuong; Struzik, Zbigniew R.; Spence, Ian
2007-07-01
Diabetes mellitus (DM) is a serious and increasing health problem worldwide. Compared to non-diabetics, patients experience an increased risk of all cardiovascular diseases, including dysfunctional neural control of the heart. Poor diagnoses of cardiac autonomic neuropathy (CAN) may result in increased incidence of silent myocardial infarction and ischaemia, which can lead to sudden death. Traditionally the Ewing battery of tests is used to identify CAN. The purpose of this study is to examine the usefulness of heart rate variability (HRV) analyses of short-term ECG recordings as a method for detecting CAN. HRV may be able to identify asymptomatic individuals, which the Ewing battery is not able to do. Several HRV parameters are assessed, including time and frequency domain, as well as nonlinear parameters. Eighteen out of thirty-eight individuals with diabetes were positive for two or more of the Ewing battery of tests indicating CAN. Approximate Entropy (ApEn), log normalized total power (LnTP) and log normalized high frequency (LnHF) power demonstrate a significant difference at p < 0.05 between CAN+ and CAN-. This indicates that nonlinear scaling parameters are able to identify people with cardiac autonomic neuropathy in short ECG recordings. Our study paves the way to assess the utility of nonlinear parameters in identifying asymptomatic CAN.
40 CFR 98.195 - Procedures for estimating missing data.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 22 2012-07-01 2012-07-01 false Procedures for estimating missing data... estimating missing data. For the procedure in § 98.193(b)(1), a complete record of all measured parameters... available process data or data used for accounting purposes. (b) For missing values related to the CaO and...
40 CFR 98.195 - Procedures for estimating missing data.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 21 2011-07-01 2011-07-01 false Procedures for estimating missing data... estimating missing data. For the procedure in § 98.193(b)(1), a complete record of all measured parameters... available process data or data used for accounting purposes. (b) For missing values related to the CaO and...
40 CFR 98.195 - Procedures for estimating missing data.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Procedures for estimating missing data... estimating missing data. For the procedure in § 98.193(b)(2), a complete record of all measured parameters... process data or data used for accounting purposes. (b) For missing values related to the CaO and MgO...
40 CFR 98.195 - Procedures for estimating missing data.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 22 2013-07-01 2013-07-01 false Procedures for estimating missing data... estimating missing data. For the procedure in § 98.193(b)(1), a complete record of all measured parameters... available process data or data used for accounting purposes. (b) For missing values related to the CaO and...
Potential for geophysical experiments in large scale tests.
Dieterich, J.H.
1981-01-01
Potential research applications for large-specimen geophysical experiments include measurements of scale dependence of physical parameters and examination of interactions with heterogeneities, especially flaws such as cracks. In addition, increased specimen size provides opportunities for improved recording resolution and greater control of experimental variables. Large-scale experiments using a special purpose low stress (100MPa).-Author
Kim, Myung Jun
2017-01-01
Purpose. To study the correlation between ocular parameters and subjective pain that patients perceived during phacoemulsification. Methods. Medical records of 142 patients who underwent standard phacoemulsification under topical anesthesia between March and August 2016 were retrospectively reviewed. The pain during phacoemulsification and 1 h after surgery was assessed and compared using a visual analog scale. In addition, demographic data, preoperative biometric parameters, and intraoperative surgical parameters were recorded. Results. Mean age of patients was 67.49 ± 12.50 years. The mean pain score was 2.26 ± 0.85 during phacoemulsification and 0.40 ± 0.69 postoperatively. Intraoperative pain was significantly associated with higher preoperative intraocular pressure (β = 0.220, P = 0.016), greater anterior chamber depth (β = 0.210, P = 0.028), and greater axial length (β = 0.181, P = 0.043). Conclusions. To reduce the subjective pain when patients have high preoperative intraocular pressure, large anterior chamber depth, or great axial length, supplementary procedures may be required. PMID:28491473
Broux, B; De Clercq, D; Decloedt, A; Ven, S; Vera, L; van Steenkiste, G; Mitchell, K; Schwarzwald, C; van Loon, G
2017-11-01
Atrial fibrillation (AF) is the most common pathological arrhythmia in horses. After successful treatment, recurrence is common. Heart rate monitors are easily applicable in horses and some devices offer basic heart rate variability (HRV) calculations. If HRV can be used to distinguish between AF and sinus rhythm (SR), this could become a monitoring tool for horses at risk for recurrence of AF. The purpose of this study was to assess whether in horses AF (before cardioversion) and SR (after cardioversion) can be differentiated based upon HRV parameters. Cohort study with internal controls. Six HRV parameters were determined in 20 horses, both in AF and in SR, at rest (2- and 5-min and 1- and 4-h recordings) and during exercise (walk and trot, 2-min recordings). Time-domain (standard deviation of the NN intervals, root mean squared successive differences in NN intervals and triangular index), frequency domain (low/high frequency ratio) and nonlinear parameters (standard deviation of the Poincaré plot [SD]1 and SD2) were used. Statistical analysis was done using paired Wilcoxon signed rank tests and receiver operating characteristic curves. HRV was higher during AF compared to SR. Results for the detection of AF were good (area under the receiver operating characteristic curve [AUC] 0.8-1) for most HRV parameters. Root mean squared successive differences in NN intervals and SD1 yielded the best results (AUC 0.9-1). Sensitivity and specificity were high for all parameters at all recordings, but highest during exercise. Although AUCs improved with longer recordings, short recordings were also good (AUC 0.8-1) for the detection of AF. In horses with frequent second degree atrioventricular block, HRV at rest is increased and recordings at walk or trot are recommended. Animals served as their own controls and there was no long-term follow-up to identify AF recurrence. AF (before cardioversion) and SR (after cardioversion) could be distinguished with HRV. This technique has promise as a monitoring tool in horses at risk for AF development. © 2017 EVJ Ltd.
Mutoh, Tomoko; Mutoh, Tatsushi; Takada, Makoto; Doumura, Misato; Ihara, Masayo; Taki, Yasuyuki; Tsubone, Hirokazu; Ihara, Masahiro
2016-01-01
[Purpose] This case series aims to evaluate the effects of hippotherapy on gait and balance ability of children and adolescents with cerebral palsy using quantitative parameters for physical activity. [Subjects and Methods] Three patients with gait disability as a sequela of cerebral palsy (one female and two males; age 5, 12, and 25 years old) were recruited. Participants received hippotherapy for 30 min once a week for 2 years. Gait parameters (step rate, step length, gait speed, mean acceleration, and horizontal/vertical displacement ratio) were measured using a portable motion recorder equipped with a tri-axial accelerometer attached to the waist before and after a 10-m walking test. [Results] There was a significant increase in step length between before and after a single hippotherapy session. Over the course of 2 year intervention, there was a significant increase in step rate, gait speed, step length, and mean acceleration and a significant improvement in horizontal/vertical displacement ratio. [Conclusion] The data suggest that quantitative parameters derived from a portable motion recorder can track both immediate and long-term changes in the walking ability of children and adolescents with cerebral palsy undergoing hippotherapy. PMID:27821971
Remote control of the industry processes. POWERLINK protocol application
NASA Astrophysics Data System (ADS)
Wóbel, A.; Paruzel, D.; Paszkiewicz, B.
2017-08-01
The present technological development enables the use of solutions characterized by a lower failure rate, and work with greater precision. This allows you to obtain the most efficient production, high speed production and reliability of individual components. The main scope of this article was POWERLINK protocol application for communication with the controller B & R through communication Ethernet for recording process parameters. This enables control of run production cycle using an internal network connected to the PC industry. Knowledge of the most important parameters of the production in real time allows detecting of a failure immediately after occurrence. For this purpose, the position of diagnostic use driver X20CP1301 B&R to record measurement data such as pressure, temperature valve between the parties and the torque required to change the valve setting was made. The use of POWERLINK protocol allows for the transmission of information on the status of every 200 μs.
Kölling, Sarah; Endler, Stefan; Ferrauti, Alexander; Meyer, Tim; Kellmann, Michael
2016-01-01
This study compared subjective with objective sleep parameters among 72 physical education students. Furthermore, the study determined whether 24-hr recording differs from nighttime recording only. Participants wore the SenseWear Armband™ for three consecutive nights and kept a sleep log. Agreement rates ranged from moderate to low for sleep onset latency (ICC = 0.39 to 0.70) and wake after sleep onset (ICC = 0.22 to 0.59), while time in bed (ICC = 0.93 to 0.95) and total sleep time (ICC = 0.90 to 0.92) revealed strong agreement during this period. Comparing deviations between 24-hr wearing time (n = 24) and night-only application (n = 20) revealed no statistical difference (p > 0.05). As athletic populations have yet to be investigated for these purposes, this study provides useful indicators and practical implications for future studies.
Dependence of cerebral-cortex activation in women on environmental factors
NASA Astrophysics Data System (ADS)
Pavlov, K. I.; Mukhin, V. N.; Kamenskaya, V. G.; Klimenko, V. M.
2016-12-01
The investigation of female physiological reactions to different meteorological conditions and space weather is relevant, since there are little experimental findings in this field. The purpose of this work is to determine how the level of cerebral-cortex activity in women depends on the meteorological and cosmophysical parameters of weather and space processes. We studied electroencephalograms (EEGs) recorded at rest in the sitting position and with eyes closed. We performed four series of measurements of brain bioelectrical activity from February to June 2013. We found that the level of cortical activity recorded by EEG changed significantly during these 6 months. Significant differences were detected between the cortical activity and the parameters of weather and space processes; namely, an increase in the air temperature and a decrease in the wind speed and cosmic-ray energy result in a decrease in the activity rate of the right occipital lobe.
Rast, Georg; Weber, Jürgen; Disch, Christoph; Schuck, Elmar; Ittrich, Carina; Guth, Brian D
2015-01-01
Human induced pluripotent stem cell-derived cardiomyocytes are available from various sources and they are being evaluated for safety testing. Several platforms are available offering different assay principles and read-out parameters: patch-clamp and field potential recording, imaging or photometry, impedance measurement, and recording of contractile force. Routine use will establish which assay principle and which parameters best serve the intended purpose. We introduce a combination of field potential recording and calcium ratiometry from spontaneously beating cardiomyocytes as a novel assay providing a complementary read-out parameter set. Field potential recording is performed using a commercial multi-well multi-electrode array platform. Calcium ratiometry is performed using a fiber optic illumination and silicon avalanche photodetectors. Data condensation and statistical analysis are designed to enable statistical inference of differences and equivalence with regard to a solvent control. Simultaneous recording of field potentials and calcium transients from spontaneously beating monolayers was done in a nine-well format. Calcium channel blockers (e.g. nifedipine) and a blocker of calcium store release (ryanodine) can be recognized and discriminated based on the calcium transient signal. An agonist of L-type calcium channels, FPL 64176, increased and prolonged the calcium transient, whereas BAY K 8644, another L-type calcium channel agonist, had no effect. Both FPL 64176 and various calcium channel antagonists have chronotropic effects, which can be discriminated from typical "chronotropic" compounds, like (±)isoprenaline (positive) and arecaidine propargyl ester (negative), based on their effects on the calcium transient. Despite technical limitations in temporal resolution and exact matching of composite calcium transient with the field potential of a subset of cells, the combined recording platform enables a refined interpretation of the field potential recording and a more reliable identification of drug effects on calcium handling. Copyright © 2015 Elsevier Inc. All rights reserved.
Nakamura, K
1978-09-01
With this system, several parameters can be recorded continuously over several months without exterior stimuli. Time per revolution is counted and punched into the paper tape as binary coded numbers, and the number of revolutions and the frequency of "passage" in a given time are printed out on a rolled paper by a digital recorder. "Passage" is defined as one revolving trial without a pause over a fixed time (criterion time) and used as a behavioral unit of "stop and go". The raw data on the paper tape are processed and analyzed with a general-purpose computer. It was confirmed that when a mouse became well accustomed to the revolving activity cage, the time per revolution followed the law of exponential distribution probability, while the length of passage (i.e. the number of revolutions per revolving trial) followed that of geometrical distribution probability. The revolving activity of mice treated with single subcutaneous injection of methamphetamine was examined using these parameters.
Capturing Revolute Motion and Revolute Joint Parameters with Optical Tracking
NASA Astrophysics Data System (ADS)
Antonya, C.
2017-12-01
Optical tracking of users and various technical systems are becoming more and more popular. It consists of analysing sequence of recorded images using video capturing devices and image processing algorithms. The returned data contains mainly point-clouds, coordinates of markers or coordinates of point of interest. These data can be used for retrieving information related to the geometry of the objects, but also to extract parameters for the analytical model of the system useful in a variety of computer aided engineering simulations. The parameter identification of joints deals with extraction of physical parameters (mainly geometric parameters) for the purpose of constructing accurate kinematic and dynamic models. The input data are the time-series of the marker’s position. The least square method was used for fitting the data into different geometrical shapes (ellipse, circle, plane) and for obtaining the position and orientation of revolute joins.
Khanduja, Sumeet; Sampangi, Raju; Hemlatha, B C; Singh, Satvir; Lall, Ashish
2018-01-01
Purpose: The purpose of this study is to describe the use of commercial digital single light reflex (DSLR) for vitreoretinal surgery recording and compare it to standard 3-chip charged coupling device (CCD) camera. Methods: Simultaneous recording was done using Sony A7s2 camera and Sony high-definition 3-chip camera attached to each side of the microscope. The videos recorded from both the camera systems were edited and sequences of similar time frames were selected. Three sequences that selected for evaluation were (a) anterior segment surgery, (b) surgery under direct viewing system, and (c) surgery under indirect wide-angle viewing system. The videos of each sequence were evaluated and rated on a scale of 0-10 for color, contrast, and overall quality Results: Most results were rated either 8/10 or 9/10 for both the cameras. A noninferiority analysis by comparing mean scores of DSLR camera versus CCD camera was performed and P values were obtained. The mean scores of the two cameras were comparable for each other on all parameters assessed in the different videos except of color and contrast in posterior pole view and color on wide-angle view, which were rated significantly higher (better) in DSLR camera. Conclusion: Commercial DSLRs are an affordable low-cost alternative for vitreoretinal surgery recording and may be used for documentation and teaching. PMID:29283133
J.H. Gove; D.Y. Hollinger; D.Y. Hollinger
2006-01-01
A dual unscented Kalman filter (UKF) was used to assimilate net CO2 exchange (NEE) data measured over a spruce-hemlock forest at the Howland AmeriFlux site in Maine, USA, into a simple physiological model for the purpose of filling gaps in an eddy flux time series. In addition to filling gaps in the measurement record, the UKF approach provides continuous estimates of...
Reliable sagittal plane kinematic gait assessments are feasible using low-cost webcam technology.
Saner, Robert J; Washabaugh, Edward P; Krishnan, Chandramouli
2017-07-01
Three-dimensional (3-D) motion capture systems are commonly used for gait analysis because they provide reliable and accurate measurements. However, the downside of this approach is that it is expensive and requires technical expertise; thus making it less feasible in the clinic. To address this limitation, we recently developed and validated (using a high-precision walking robot) a low-cost, two-dimensional (2-D) real-time motion tracking approach using a simple webcam and LabVIEW Vision Assistant. The purpose of this study was to establish the repeatability and minimal detectable change values of hip and knee sagittal plane gait kinematics recorded using this system. Twenty-one healthy subjects underwent two kinematic assessments while walking on a treadmill at a range of gait velocities. Intraclass correlation coefficients (ICC) and minimal detectable change (MDC) values were calculated for commonly used hip and knee kinematic parameters to demonstrate the reliability of the system. Additionally, Bland-Altman plots were generated to examine the agreement between the measurements recorded on two different days. The system demonstrated good to excellent reliability (ICC>0.75) for all the gait parameters tested on this study. The MDC values were typically low (<5°) for most of the parameters. The Bland-Altman plots indicated that there was no systematic error or bias in kinematic measurements and showed good agreement between measurements obtained on two different days. These results indicate that kinematic gait assessments using webcam technology can be reliably used for clinical and research purposes. Copyright © 2017 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Madlazim,, E-mail: m-lazim@physics.its.ac.id; Hariyono, E., E-mail: m-lazim@physics.its.ac.id
The purpose of the study was to estimate P-wave rupture durations (T{sub dur}), dominant periods (T{sub d}) and exceeds duration (T{sub 50Ex}) simultaneously for local events, shallow earthquakes which occurred off the coast of Indonesia. Although the all earthquakes had parameters of magnitude more than 6,3 and depth less than 70 km, part of the earthquakes generated a tsunami while the other events (Mw=7.8) did not. Analysis using Joko Tingkir of the above stated parameters helped understand the tsunami generation of these earthquakes. Measurements from vertical component broadband P-wave quake velocity records and determination of the above stated parameters canmore » provide a direct procedure for assessing rapidly the potential for tsunami generation. The results of the present study and the analysis of the seismic parameters helped explain why the events generated a tsunami, while the others did not.« less
NASA Astrophysics Data System (ADS)
Ramesha, D. K.; Thimmannachar, Rajiv K.; Simhasan, R.; Nagappa, Manjunath; Gowda, P. M.
2012-07-01
Bio-fuel is a clean burning fuel made from natural renewable energy resource; it operates in C. I. engine similar to the petroleum diesel. The rising cost of diesel and the danger caused to the environment has led to an intensive and desperate search for alternative fuels. Among them, animal fats like the fish oil have proven to be a promising substitute to diesel. In this experimental study, A computerized 4-stroke, single cylinder, constant speed, direct injection diesel engine was operated on fish oil-biodiesel of different blends. Three different blends of 10, 20, and 30 % by volume were used for this study. Various engine performance, combustion and emission parameters such as Brake Thermal Efficiency, Brake Specific Fuel Consumption, Heat Release Rate, Peak Pressure, Exhaust Gas Temperature, etc. were recorded from the acquired data. The data was recorded with the help of an engine analysis software. The recorded parameters were studied for varying loads and their corresponding graphs have been plotted for comparison purposes. Petroleum Diesel has been used as the reference. From the properties and engine test results it has been established that fish oil biodiesel is a better replacement for diesel without any engine modification.
Multi-model approach to characterize human handwriting motion.
Chihi, I; Abdelkrim, A; Benrejeb, M
2016-02-01
This paper deals with characterization and modelling of human handwriting motion from two forearm muscle activity signals, called electromyography signals (EMG). In this work, an experimental approach was used to record the coordinates of a pen tip moving on the (x, y) plane and EMG signals during the handwriting act. The main purpose is to design a new mathematical model which characterizes this biological process. Based on a multi-model approach, this system was originally developed to generate letters and geometric forms written by different writers. A Recursive Least Squares algorithm is used to estimate the parameters of each sub-model of the multi-model basis. Simulations show good agreement between predicted results and the recorded data.
Code of Federal Regulations, 2011 CFR
2011-10-01
... use of such record for a purpose compatible with the purpose for which it was collected, including... purposes ordered by a court referral to potential employers, and for security clearance; Statistical record means a record in a system of records maintained for statistical research or reporting purposes only and...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Diener, T; Wilkinson, D
Purpose: To improve workflow efficiency and patient safety by assessing the quality control documentation for HDR brachytherapy within our Electronic Medical Record System (Mosaiq). Methods: A list of parameters based on NRC regulations, our quality management program (QMP), recommendations of the ACR and the American Brachytherapy Society, and HDR treatment planning risks identified in our previous FMEA study was made. Next, the parameter entries were classified according to the type of data input—manual, electronic, or both. Manual entry included the electronic Brachytherapy Treatment Record (BTR) and pre-treatment Mosaiq Assessments list. Oncentra Treatment Reports (OTR) from the Oncentra Treatment Control Systemmore » constituted the electronic data. The OTR includes a Pre-treatment Report for each fraction, and a Treatment Summary Report at the completion of treatment. Each entry was then examined for appropriateness and completeness of data; adjustments and additions as necessary were then made. Results: Ten out of twenty-one recorded treatment parameters were identified to be documented within both the BTR and OTR. Of these ten redundancies, eight were changed from recorded values to a simple checklist in the BTR to avoid recording errors. The other redundancies were kept in both documents due to their value to ensuring patient safety. An edit was made to the current BTR quality assessment; this change revises the definition of a medical event in accordance with ODH Regulation 3701:1-58-101. One addition was made to the current QMP documents regarding HDR. This addition requires a physician to be present through the duration of HDR treatment in accordance with ODH Regulation 3701:1-58-59; Paragraph (F); Section (2); Subsection (a). Conclusion: Careful examination of HDR documentation that originates from different sources can help to improve the accuracy and reliability of the documents. In addition, there may be a small improvement in efficiency due to elimination of unnecessary redundancies.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marekova, Elisaveta
Series of relatively large earthquakes in different regions of the Earth are studied. The regions chooses are of a high seismic activity and has a good contemporary network for recording of the seismic events along them. The main purpose of this investigation is the attempt to describe analytically the seismic process in the space and time. We are considering the statistical distributions the distances and the times between consecutive earthquakes (so called pair analysis). Studies conducted on approximating the statistical distribution of the parameters of consecutive seismic events indicate the existence of characteristic functions that describe them best. Such amore » mathematical description allows the distributions of the examined parameters to be compared to other model distributions.« less
NASA Astrophysics Data System (ADS)
Verhoeven, G.; Wieser, M.; Briese, C.; Doneus, M.
2013-07-01
Since manned, airborne aerial reconnaissance for archaeological purposes is often characterised by more-or-less random photographing of archaeological features on the Earth, the exact position and orientation of the camera during image acquisition becomes very important in an effective inventorying and interpretation workflow of these aerial photographs. Although the positioning is generally achieved by simultaneously logging the flight path or directly recording the camera's position with a GNSS receiver, this approach does not allow to record the necessary roll, pitch and yaw angles of the camera. The latter are essential elements for the complete exterior orientation of the camera, which allows - together with the inner orientation of the camera - to accurately define the portion of the Earth recorded in the photograph. This paper proposes a cost-effective, accurate and precise GNSS/IMU solution (image position: 2.5 m and orientation: 2°, both at 1σ) to record all essential exterior orientation parameters for the direct georeferencing of the images. After the introduction of the utilised hardware, this paper presents the developed software that allows recording and estimating these parameters. Furthermore, this direct georeferencing information can be embedded into the image's metadata. Subsequently, the first results of the estimation of the mounting calibration (i.e. the misalignment between the camera and GNSS/IMU coordinate frame) are provided. Furthermore, a comparison with a dedicated commercial photographic GNSS/IMU solution will prove the superiority of the introduced solution. Finally, an outlook on future tests and improvements finalises this article.
Scharf, A; Staboulidou, I; Günter, H H; Wüstemann, M; Sohn, C
2003-01-01
Acupuncture as a non-evidence-based therapy modality is widely used in obstetrics prior to and during delivery. Thus far, only few studies investigated the impact of acupuncture on obstetric surveillance parameters like cardiotocography. The aim of this study was to control the effect of clearly-defined acupuncture on CTG parameters. 61 low-risk singleton pregnancies between 30 + 0 and 39 + 6 weeks of gestation were prospectively treated with acupuncture at GV 20 and ST 36 bilaterally for the purpose of maternal relaxation by the same investigator under CTG control. Before (Phase 1), during (Phase 2) and after (Phase 3) treatment the cardiotocogram was recorded. Controlled parameters of outcome were the Fisher score, uterine activity (Phase 1, 2, 3) and maternal blood pressure and pulse before (Phase 1) and after (Phase 2) administration of acupuncture. In a matched control group, 60 pregnant women were monitored by an identical scheme without application of acupuncture and the same outcome parameters were recorded. : The CTG analysis revealed a statistically significant increase of the Fisher score as well as uterine activity which tended to trace back to pretherapeutic initial values. The systolic maternal blood pressure was found to show a statistically significant decrease while diastolic blood pressure and pulse frequency remained unchanged. In the control group, the comparison of phase 1 vs. phase 2 showed a statistically significant increase of the Fischer score and uterine activity. During phase 3 the Fischer score further increased in contrast to a statistically significant slight reduction of uterine activity. Maternal systolic blood pressure measured at the end of phase 2 was found to be statistically reduced while diastolic blood pressure and pulse remained unchanged. The extent of the systolic blood pressure reduction was markedly higher in the acupuncture group as compared to the control group. Antenatal acupuncture as a reflex therapy for the purpose of maternal relaxation seems to exert an influence on short-term alterations of the fetal activity (transient increase in terms of Fischer score) with reversibly increased uterine activity as detected by cardiotocography. Also, a slight reduction of the maternal blood pressure seems to be effected. The phenomena recorded in the control group (relaxation without supportive acupuncture treatment) revealed to be partially concordant (reversibly increased uterine activity, mild maternal reduction of systolic blood pressure) and partially discordant (persisting increase of Fischer score) as compared with the acupuncture group. Acupuncture seems not only to have a psychological, but also a short-term somatic effect with direct influence on maternal and fetal circulation parameters. Other established surveillance parameters and different points of acupuncture should be studied to further elucidate the underlying interaction as well as the duration of this effect.
Telemetric measurement system of beehive environment conditions
NASA Astrophysics Data System (ADS)
Walendziuk, Wojciech; Sawicki, Aleksander
2014-11-01
This work presents a measurement system of beehive environmental conditions. The purpose of the device is to perform measurements of parameters such as ambient temperature, atmospheric pressure, internal temperature, humidity and sound level. The measured values were transferred to the MySQL database, which is located on an external server, with the use of GPRS protocol. A website presents the measurement data in the form of tables and graphs. The study also shows exemplary results of environmental conditions measurements recorded in the beehive by hour cycle.
Sewer deterioration modeling with condition data lacking historical records.
Egger, C; Scheidegger, A; Reichert, P; Maurer, M
2013-11-01
Accurate predictions of future conditions of sewer systems are needed for efficient rehabilitation planning. For this purpose, a range of sewer deterioration models has been proposed which can be improved by calibration with observed sewer condition data. However, if datasets lack historical records, calibration requires a combination of deterioration and sewer rehabilitation models, as the current state of the sewer network reflects the combined effect of both processes. Otherwise, physical sewer lifespans are overestimated as pipes in poor condition that were rehabilitated are no longer represented in the dataset. We therefore propose the combination of a sewer deterioration model with a simple rehabilitation model which can be calibrated with datasets lacking historical information. We use Bayesian inference for parameter estimation due to the limited information content of the data and limited identifiability of the model parameters. A sensitivity analysis gives an insight into the model's robustness against the uncertainty of the prior. The analysis reveals that the model results are principally sensitive to the means of the priors of specific model parameters, which should therefore be elicited with care. The importance sampling technique applied for the sensitivity analysis permitted efficient implementation for regional sensitivity analysis with reasonable computational outlay. Application of the combined model with both simulated and real data shows that it effectively compensates for the bias induced by a lack of historical data. Thus, the novel approach makes it possible to calibrate sewer pipe deterioration models even when historical condition records are lacking. Since at least some prior knowledge of the model parameters is available, the strength of Bayesian inference is particularly evident in the case of small datasets. Copyright © 2013 Elsevier Ltd. All rights reserved.
Massobrio, Giuseppe; Martinoia, Sergio; Massobrio, Paolo
2018-02-01
In the latest years, several attempts to develop extracellular microtransducers to record electrophysiological activity of excitable cells have been done. In particular, many efforts have been oriented to increase the coupling conditions, and, thus, improving the quality of the recorded signal. Gold mushroom-shaped microelectrodes (GMμE) are an example of nano-devices to achieve those requirements. In this study, we developed an equivalent electrical circuit of the neuron-microelectrode system interface to simulate signal recordings from both planar and engulfed micro-nano-electrodes. To this purpose, models of the neuron, planar, gold planar microelectrode, and GMμE, neuro-electronic junction (microelectrode-electrolyte interface, cleft effect, and protein-glycocalyx electric double layer) are presented. Then, neuronal electrical activity is simulated by Hspice software, and analyzed as a function of the most sensitive biophysical models parameters, such as the neuron-microelectrode cleft width, spreading and seal resistances, ion-channel densities, double-layer properties, and microelectrode geometries. Results are referenced to the experimentally recorded electrophysiological neuronal signals reported in the literature.
Grounding, bonding and shielding for safety and signal interference control
NASA Technical Reports Server (NTRS)
Forsyth, T. J.; Bautista, AL
1990-01-01
Aircraft models and other aerodynamic tests are conducted at the NASA Ames Research Center National Full Scale Aerodynamics Complex (NFAC). The models, tested in NFAC's wind tunnels, are sometimes heavily instrumented and are connected to a data acquisition system. Besides recording data for evaluation, certain critical information must be monitored to be sure the model is within operational limits. The signals for these parameters are for the most part low-level signals that require good instrumentation amplification. These amplifiers need to be grounded and shielded for common mode rejection and noise reduction. The instrumentation also needs to be grounded to prevent electrical shock hazards. The purpose of this paper is to present an understanding of the principles and purpose of grounding, bonding, and shielding.
Computer implemented method, and apparatus for controlling a hand-held tool
NASA Technical Reports Server (NTRS)
Wagner, Kenneth William (Inventor); Taylor, James Clayton (Inventor)
1999-01-01
The invention described here in is a computer-implemented method and apparatus for controlling a hand-held tool. In particular, the control of a hand held tool is for the purpose of controlling the speed of a fastener interface mechanism and the torque applied to fasteners by the fastener interface mechanism of the hand-held tool and monitoring the operating parameters of the tool. The control is embodied in intool software embedded on a processor within the tool which also communicates with remote software. An operator can run the tool, or through the interaction of both software, operate the tool from a remote location, analyze data from a performance history recorded by the tool, and select various torque and speed parameters for each fastener.
SU-F-T-458: Tracking Trends of TG-142 Parameters Via Analysis of Data Recorded by 2D Chamber Array
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alexandrian, A; Kabat, C; Defoor, D
Purpose: With increasing QA demands of medical physicists in clinical radiation oncology, the need for an effective method of tracking clinical data has become paramount. A tool was produced which scans through data automatically recorded by a 2D chamber array and extracts relevant information recommended by TG-142. Using this extracted information a timely and comprehensive analysis of QA parameters can be easily performed enabling efficient monthly checks on multiple linear accelerators simultaneously. Methods: A PTW STARCHECK chamber array was used to record several months of beam outputs from two Varian 2100 series linear accelerators and a Varian NovalisTx−. In conjunctionmore » with the chamber array, a beam quality phantom was used to simultaneously to determine beam quality. A minimalist GUI was created in MatLab that allows a user to set the file path of the data for each modality to be analyzed. These file paths are recorded to a MatLab structure and then subsequently accessed by a script written in Python (version 3.5.1) which then extracts values required to perform monthly checks as outlined by recommendations from TG-142. The script incorporates calculations to determine if the values recorded by the chamber array fall within an acceptable threshold. Results: Values obtained by the script are written to a spreadsheet where results can be easily viewed and annotated with a “pass” or “fail” and saved for further analysis. In addition to creating a new scheme for reviewing monthly checks, this application allows for able to succinctly store data for follow up analysis. Conclusion: By utilizing this tool, parameters recommended by TG-142 for multiple linear accelerators can be rapidly obtained and analyzed which can be used for evaluation of monthly checks.« less
Early Shear Failure Prediction in Incremental Sheet Forming Process Using FEM and ANN
NASA Astrophysics Data System (ADS)
Moayedfar, Majid; Hanaei, Hengameh; Majdi Rani, Ahmad; Musa, Mohd Azam Bin; Sadegh Momeni, Mohammad
2018-03-01
The application of incremental sheet forming process as a rapid forming technique is rising in variety of industries such as aerospace, automotive and biomechanical purposes. However, the sheet failure is a big challenge in this process which leads wasting lots of materials. Hence, this study tried to propose a method to predict the early sheet failure in this process using mathematical solution. For the feasibility of the study, design of experiment with the respond surface method is employed to extract a set of experiments data for the simulation. The significant forming parameters were recognized and their integration was used for prediction system. Then, the results were inserted to the artificial neural network as input parameters to predict a vast range of applicable parameters avoiding sheet failure in ISF. The value of accuracy R2 ∼0.93 was obtained and the maximum sheet stretch in the depth of 25mm were recorded. The figures generate from the trend of interaction between effective parameters were provided for future studies.
Geological and vegetational applications of Shuttle Imaging Radar-B, Mineral County, Nevada
NASA Technical Reports Server (NTRS)
Borengasser, M. X.; Kleiner, E. F.; Peterson, F. F.; Klieforth, H.; Vreeland, P.
1988-01-01
Multiple-incidence angle and multi-azimuth radar data were acquired from a Shuttle platform over test sites in Nevada in October 1984. An attempt was made to correlate these data with ground features for the purpose of evaluating the use of such data for geological and vegetational assessment. Standard ecological parameters with respect to the flora (community composition, dominance, and relative cover) were recorded in the field at the time of overflight. Although a total of 33 species representing 11 plant families were recognized, and plant cover ranged from 13 to 26 percent, radar data could not be used to separate plant communities. The signal return is more a function of abiotic conditions than vegetative characteristics. Illumination geometry plays an important role in the ability to detect strike-slip and dip-slip faults. Local incidence angle is the most important parameter, and SIR-B data takes with small incidence angles are superior for identifying certain styles of faulting. Look direction is critical for detecting faults with a dip-slip component. New structural features were not observed. Problems with radar antenna power and recording significantly affected data quality.
36 CFR 1206.30 - What is the scope and purpose of records grants?
Code of Federal Regulations, 2010 CFR
2010-07-01
... of records grants? 1206.30 Section 1206.30 Parks, Forests, and Public Property NATIONAL ARCHIVES AND... Grants § 1206.30 What is the scope and purpose of records grants? (a) Records grants support projects... the purpose of furthering an understanding and appreciation of United States history and assuring the...
Marto, Aminaton; Jahed Armaghani, Danial; Tonnizam Mohamad, Edy; Makhtar, Ahmad Mahir
2014-01-01
Flyrock is one of the major disturbances induced by blasting which may cause severe damage to nearby structures. This phenomenon has to be precisely predicted and subsequently controlled through the changing in the blast design to minimize potential risk of blasting. The scope of this study is to predict flyrock induced by blasting through a novel approach based on the combination of imperialist competitive algorithm (ICA) and artificial neural network (ANN). For this purpose, the parameters of 113 blasting operations were accurately recorded and flyrock distances were measured for each operation. By applying the sensitivity analysis, maximum charge per delay and powder factor were determined as the most influential parameters on flyrock. In the light of this analysis, two new empirical predictors were developed to predict flyrock distance. For a comparison purpose, a predeveloped backpropagation (BP) ANN was developed and the results were compared with those of the proposed ICA-ANN model and empirical predictors. The results clearly showed the superiority of the proposed ICA-ANN model in comparison with the proposed BP-ANN model and empirical approaches. PMID:25147856
Marto, Aminaton; Hajihassani, Mohsen; Armaghani, Danial Jahed; Mohamad, Edy Tonnizam; Makhtar, Ahmad Mahir
2014-01-01
Flyrock is one of the major disturbances induced by blasting which may cause severe damage to nearby structures. This phenomenon has to be precisely predicted and subsequently controlled through the changing in the blast design to minimize potential risk of blasting. The scope of this study is to predict flyrock induced by blasting through a novel approach based on the combination of imperialist competitive algorithm (ICA) and artificial neural network (ANN). For this purpose, the parameters of 113 blasting operations were accurately recorded and flyrock distances were measured for each operation. By applying the sensitivity analysis, maximum charge per delay and powder factor were determined as the most influential parameters on flyrock. In the light of this analysis, two new empirical predictors were developed to predict flyrock distance. For a comparison purpose, a predeveloped backpropagation (BP) ANN was developed and the results were compared with those of the proposed ICA-ANN model and empirical predictors. The results clearly showed the superiority of the proposed ICA-ANN model in comparison with the proposed BP-ANN model and empirical approaches.
32 CFR 34.40 - Purpose of reports and records.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 32 National Defense 1 2012-07-01 2012-07-01 false Purpose of reports and records. 34.40 Section 34.40 National Defense Department of Defense OFFICE OF THE SECRETARY OF DEFENSE DoD GRANT AND AGREEMENT... Requirements Reports and Records § 34.40 Purpose of reports and records. Sections 34.41 and 34.42 prescribe...
32 CFR 34.40 - Purpose of reports and records.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 32 National Defense 1 2014-07-01 2014-07-01 false Purpose of reports and records. 34.40 Section 34.40 National Defense Department of Defense OFFICE OF THE SECRETARY OF DEFENSE DoD GRANT AND AGREEMENT... Requirements Reports and Records § 34.40 Purpose of reports and records. Sections 34.41 and 34.42 prescribe...
32 CFR 34.40 - Purpose of reports and records.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 32 National Defense 1 2013-07-01 2013-07-01 false Purpose of reports and records. 34.40 Section 34.40 National Defense Department of Defense OFFICE OF THE SECRETARY OF DEFENSE DoD GRANT AND AGREEMENT... Requirements Reports and Records § 34.40 Purpose of reports and records. Sections 34.41 and 34.42 prescribe...
32 CFR 34.40 - Purpose of reports and records.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 32 National Defense 1 2011-07-01 2011-07-01 false Purpose of reports and records. 34.40 Section 34.40 National Defense Department of Defense OFFICE OF THE SECRETARY OF DEFENSE DoD GRANT AND AGREEMENT... Requirements Reports and Records § 34.40 Purpose of reports and records. Sections 34.41 and 34.42 prescribe...
32 CFR 34.40 - Purpose of reports and records.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 32 National Defense 1 2010-07-01 2010-07-01 false Purpose of reports and records. 34.40 Section 34.40 National Defense Department of Defense OFFICE OF THE SECRETARY OF DEFENSE DoD GRANT AND AGREEMENT... Requirements Reports and Records § 34.40 Purpose of reports and records. Sections 34.41 and 34.42 prescribe...
NASA Astrophysics Data System (ADS)
Kisi, Ozgur; Ay, Murat
2014-05-01
Low, medium and high values of a parameter are very important issues in climatological, meteorological and hydrological events. Moreover these values are used to decide various design parameters based on scientific aspects and real applications everywhere in the world. With this concept, a new trend method recently proposed by Şen was used for water parameters, pH, T, EC, Na+, K+, CO3-2, HCO3-, Cl-, SO4-2, B+3 and Q recorded at five different stations (station numbers and locations: 1535-Sogutluhan (Sivas), 1501-Yamula (Kayseri), 1546-Tuzkoy (Kayseri), 1503-Yahsihan (Kirsehir), and 1533-Inozu (Samsun)) selected from the Kizilirmak River in Turkey. Low, medium and high values of the parameters were graphically evaluated with this method. For comparison purposes, the Mann-Kendall trend test was also applied to the same data. Differences of the two trend tests were also emphasised. It was found that the Şen trend test compared with the MK trend test had several advantages. The results also revealed that the Şen trend test could be successfully used for trend analysis of water parameters especially in terms of evaluation of low, medium and high values of data.
NASA Astrophysics Data System (ADS)
Yang, Xiaolin; Wu, Zhongliang; Jiang, Changsheng; Xia, Min
2011-05-01
One of the important issues in macroseismology and engineering seismology is how to get as much intensity and/or strong motion data as possible. We collected and studied several cases in the May 12, 2008, Wenchuan earthquake, exploring the possibility of estimating intensities and/or strong ground motion parameters using civilian monitoring videos which were deployed originally for security purposes. We used 53 video recordings in different places to determine the intensity distribution of the earthquake, which is shown to be consistent with the intensity distribution mapped by field investigation, and even better than that given by the Community Internet Intensity Map. In some of the videos, the seismic wave propagation is clearly visible, and can be measured with the reference of some artificial objects such as cars and/or trucks. By measuring the propagating wave, strong motion parameters can be roughly but quantitatively estimated. As a demonstration of this `propagating-wave method', we used a series of civilian videos recorded in different parts of Sichuan and Shaanxi and estimated the local PGAs. The estimate is compared with the measurement reported by strong motion instruments. The result shows that civilian monitoring video provide a practical way of collecting and estimating intensity and/or strong motion parameters, having the advantage of being dynamic, and being able to be played back for further analysis, reflecting a new trend for macroseismology in our digital era.
Simultaneous monitoring of multiple contrast agents using a hybrid MR-DOT system
NASA Astrophysics Data System (ADS)
Gulsen, Gultekin; Unlu, Mehmet Burcin; Birgul, Ozlem; Nalcioglu, Orhan
2007-02-01
Frequency domain diffuse optical tomography (DOT) is a recently emerging technique that uses arrays of sources and detectors to obtain spatially dependent optical parameters of tissue. Here, we describe the design of a hybrid MR-DOT system for dynamic imaging cancer. The combined system acquires both MR and optical data simultaneously. The performance of the system is tested with phantom and in-vivo studies. Gd-DTPA and ICG was used for this purpose and the enhancement kinetics of both agents are recorded using the hybrid system.
Nadeau, Sylvie; Labelle, Hubert
2007-01-01
Gait analysis is actually used in subjects with scoliosis to determine the change in lower limb parameters after surgery, but the reliability of these parameters still remained unknown. The purpose of this study was to assess the repeatability of traditional gait parameters in subjects with adolescent idiopathic scoliosis (AIS) and to estimate the associated standard error of measurement (SEM). A test–retest design was used to assess the reliability of gait parameters at self-selected and fast speeds. A convenience sample of 20 girls aged from 12 to 17 years, with an idiopathic scoliosis (King classification: types I, II or III; Cobb angle 17–50°) participated in the study. Five good trials were recorded on two occasions. The time-distance, kinematic, and kinetic gait parameters were recorded using foot-switches in combination with a three-dimensional motion analysis system (Optotrak) and Advanced Mechanical Technologies Inc., (AMTI) Watertown, MA, USA; force plates. The coefficients of dependability and SEM derived from the generalizability theory were used to assess the reliability. Inter-trial reliability was good for time-distance, kinematic, and kinetic (absolute and normalized) gait parameters except for the medio-lateral ground reaction force (GRF) component and the ankle dorsiflexor moment (ϕ = 0.60–0.77). Test–retest reliability was higher for the kinetic than for the kinematic parameters. These coefficients ranged from 0.42 to 0.58 for the time-distance parameters; from 0.55 to 0.88 for the angular displacements and from 0.25 to 0.99 for the kinetic parameters. The SEMs were lower than 3.3° for the angular displacements and lower than 8 Nm (0.15 Nm/kg) and 36 W (0.54 W/Kg) for the joint moments and powers regardless of the speed. Several gait parameters are reliable among subjects with AIS and can be used to assess the evolution of the spinal modifications and the impact of treatment on their lower limb gait pattern. PMID:17891424
22 CFR 226.50 - Purpose of reports and records.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Purpose of reports and records. 226.50 Section 226.50 Foreign Relations AGENCY FOR INTERNATIONAL DEVELOPMENT ADMINISTRATION OF ASSISTANCE AWARDS TO U.S. NON-GOVERNMENTAL ORGANIZATIONS Post-award Requirements Reports and Records § 226.50 Purpose of...
NASA Astrophysics Data System (ADS)
Khanmohammadi, Neda; Rezaie, Hossein; Montaseri, Majid; Behmanesh, Javad
2017-10-01
The reference evapotranspiration (ET0) plays an important role in water management plans in arid or semi-arid countries such as Iran. For this reason, the regional analysis of this parameter is important. But, ET0 process is affected by several meteorological parameters such as wind speed, solar radiation, temperature and relative humidity. Therefore, the effect of distribution type of effective meteorological variables on ET0 distribution was analyzed. For this purpose, the regional probability distribution of the annual ET0 and its effective parameters were selected. Used data in this research was recorded data at 30 synoptic stations of Iran during 1960-2014. Using the probability plot correlation coefficient (PPCC) test and the L-moment method, five common distributions were compared and the best distribution was selected. The results of PPCC test and L-moment diagram indicated that the Pearson type III distribution was the best probability distribution for fitting annual ET0 and its four effective parameters. The results of RMSE showed that the ability of the PPCC test and L-moment method for regional analysis of reference evapotranspiration and its effective parameters was similar. The results also showed that the distribution type of the parameters which affected ET0 values can affect the distribution of reference evapotranspiration.
32 CFR 32.50 - Purpose of reports and records.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 32 National Defense 1 2012-07-01 2012-07-01 false Purpose of reports and records. 32.50 Section 32.50 National Defense Department of Defense OFFICE OF THE SECRETARY OF DEFENSE DoD GRANT AND AGREEMENT..., HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Reports and Records § 32.50 Purpose of...
32 CFR 32.50 - Purpose of reports and records.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 32 National Defense 1 2013-07-01 2013-07-01 false Purpose of reports and records. 32.50 Section 32.50 National Defense Department of Defense OFFICE OF THE SECRETARY OF DEFENSE DoD GRANT AND AGREEMENT..., HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Reports and Records § 32.50 Purpose of...
32 CFR 32.50 - Purpose of reports and records.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 32 National Defense 1 2010-07-01 2010-07-01 false Purpose of reports and records. 32.50 Section 32.50 National Defense Department of Defense OFFICE OF THE SECRETARY OF DEFENSE DoD GRANT AND AGREEMENT..., HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Reports and Records § 32.50 Purpose of...
32 CFR 32.50 - Purpose of reports and records.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 32 National Defense 1 2011-07-01 2011-07-01 false Purpose of reports and records. 32.50 Section 32.50 National Defense Department of Defense OFFICE OF THE SECRETARY OF DEFENSE DoD GRANT AND AGREEMENT..., HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Reports and Records § 32.50 Purpose of...
32 CFR 32.50 - Purpose of reports and records.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 32 National Defense 1 2014-07-01 2014-07-01 false Purpose of reports and records. 32.50 Section 32.50 National Defense Department of Defense OFFICE OF THE SECRETARY OF DEFENSE DoD GRANT AND AGREEMENT..., HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Reports and Records § 32.50 Purpose of...
49 CFR 801.57 - Records compiled for law enforcement purposes.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 7 2010-10-01 2010-10-01 false Records compiled for law enforcement purposes. 801... compiled for law enforcement purposes. Pursuant to 5 U.S.C. 552(b)(7), any records compiled for law or..., would disclose investigative procedures and practices, or would endanger the life or security of law...
4 CFR 83.1 - Purpose and scope of part.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 4 Accounts 1 2011-01-01 2011-01-01 false Purpose and scope of part. 83.1 Section 83.1 Accounts GOVERNMENT ACCOUNTABILITY OFFICE RECORDS PRIVACY PROCEDURES FOR PERSONNEL RECORDS § 83.1 Purpose and scope of... maintenance and disclosure of personnel records; (b) Inform individuals of the existence of systems of...
Schlegel, Patrick; Stingl, Michael; Kunduk, Melda; Kniesburges, Stefan; Bohr, Christopher; Döllinger, Michael
2018-05-31
The phonatory process is often judged during sustained phonation by analyzing the acoustic voice signal and the vocal fold vibrations. Many formulas and parameters have been suggested for qualifying the characteristics of the acoustic signal and the vocal fold vibrations during sustained phonation. These parameters are directly computed from the acoustic signal and the endoscopic glottal area waveform (GAW). The GAW is calculated from laryngeal high-speed videoendoscopy (HSV) recordings and describes the increase and decrease of the glottal area during the phonation process, that is, the opening and closing of the two oscillating vocal folds over time. However, some of the parameters have strong mathematical dependencies with one another and some are ill-defined. The purpose of this study is to identify mathematical dependencies between parameters with the aim of reducing their numbers and suggesting which parameters may best describe the properties of the GAW and the acoustical signal. In this preliminary investigation, 20 frequently used parameters are examined: 10 GAW only and 10 both GAW and acoustic parameters. In total 13 parameters can be neglected because of mathematical dependencies. In addition, nine of these parameters show problematic features that range from unexpected behavior to ill definition. Reducing the number of parameters appears to be necessary to standardize vocal fold function analysis. This may lead to better comparability of research results from different studies. Copyright © 2018 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Construction of a measuring vehicle for recording basic data of roads
NASA Astrophysics Data System (ADS)
Wittig, Marcus; Häupl, Ronny; Hartmann, Tommy; Lehmann, Ringo; Wetzel, Dominik; Kühn, Wolfgang; Hartmann, Peter
2017-06-01
We have developed sensor units and additionally installed them on an existing measuring vehicle in order to record various road parameters. These parameters mainly include the inclination of the road both parallel and perpendicular to the travel movement, the width of the road, the detection and location of road markings and the detection of weather-related road damage. These values can be used to calculate the maximum speed, the shock absorber settings or the optimization of the driving comfort of vehicles traversing these roads. The roll-angle-module, in conjunction with the additional values given by the measuring vehicle itself, provides the transverse inclination of the road. For this purpose, the distances obtained from two infrared (IR) modules located on the outside of the vehicle are recorded in real time and the resulting angle of the vehicle with respect to the road is determined with a suitable function. This is necessary since the measured value changes of the two modules based on the rotation-related movement and the radiation characteristics of the IR modules do not have the same magnitude. Thus, without mathematical adjustment, the ascertained value of the inclination would be greater than the actual angle of vehicle to the road. This value is again calculated with the angle from the vehicle to the center of the earth, which is output directly from the vehicles accelerometers and GPS data, and the angle of the road is obtained. The angle in the direction of travel is calculated purely on the GPS data. A mesh of the road topography can be created by the superposition of the angular values at all measurement coordinates. The width module, which consists of a camera and two line lasers, provides the width of the roadway in a post-processing step. Furthermore, road markings are detected and provided with the corresponding time stamp of the video and grouped on the basis of various criteria. The lasers used here serve as a wide standard for calibration. A schematic diagram of the measuring vehicle is shown in Figure 1. The post-processing is done by means of a Python code which stores the individual frames of the recorded video one by one. By means of a routine colors are detected, a recalibration of the width over the created "green" image is executed and then the "white" image is examined on objects with specific parameters and divided into groups, such as "pedestrian crossing". The bluish-colored cameras shown in Fig. 1 are used for the stereoscopic recording of the road and the subsequent processing and recognition of road signs, traffic lights and roadside borders. The output can be saved as a text document or as a collection in the graphical user interface. Furthermore, a laser module is used to generate a structured light pattern in order to detect weather-induced influences on the road, such as potholes. For this purpose a routine was developed and adapted, which can determine the dimensions of the road defects based on the position of the imaged points and the known geometric parameters.
Küçük, Fadime; Livanelioglu, Ayşe
2015-11-01
[Purpose] Exercise is one of the most important components of a healthy life. The purpose of this study was to analyze exercise beliefs and psychosocial factors in sedentary and active healthy women and observe the changes in these parameters resulting from clinical Pilates exercises and verbal education in healthy women. [Subjects and Methods] Sixty-six healthy women were included in the study. Participants were divided into clinical Pilates (n=21), verbal education (n=25), and control groups (n=20). Prior to and at the end of the study, demographic information, body mass index, waist-hip circumference, exercise beliefs, physical activity index, and psychosocial factors (Rosenberg self-esteem scale, Body Cathexis Index, SF-36 quality of life, Beck Depression Scale, visual analog scale for tiredness) of the subjects were recorded. [Results] Meaningful changes for all the parameters took place in the clinical Pilates and verbal education groups. Our analyses indicated that the changes in the clinical Pilates group were more meaningful than those in the verbal education group. When the data of the study groups were compared with those of the control group, the clinical Pilates group showed meaningful differences. [Conclusion] The result of this study indicate that both clinical Pilates and verbal education are effective in changing exercise beliefs and physical and psychosocial parameters.
NASA Technical Reports Server (NTRS)
Mondelain, Didier; Payan, Sebastien; Deng, Wenping; Camy-Peyret, Claude; Hurtmans, Daniel; Mantz, Arlan W.
2007-01-01
We measured the temperature dependence of the nitrogen broadening, narrowing and line-mixing coefficients of four lines of the P9 manifold in the v3 band of 12CH4 for atmospheric purposes. The data were collected using our tunable diode laser (TDL) spectrometer with active wavenumber control coupled to a newly developed cold Herriott cell with a path length of 5.37 m and a temperature uniformity of better than 0.01 K along the cell. We recorded and analyzed spectra recorded at sample temperature between 90 K and room temperature. We have investigate the influence of our new results in the inversion model used to retrieve methane profiles from atmospheric spectra; our new results make it possible to retrieve significantly more precise methane profiles. The atmospheric spectra we utilized were obtained by several of us with a balloon-born Fourier Transform infrared experiment in a limb configuration. Differences up to 7% on the retrieved volume mixing ratio were found compared to an inversion model using only HITRAN04 spectroscopic parameters.
32 CFR 318.14 - Blanket routine uses.
Code of Federal Regulations, 2013 CFR
2013-07-01
... of Personnel Management. A record from a system of records subject to the Privacy Act and maintained... the General Services Administration (GSA) for the purpose of records management inspections conducted... purpose of records management inspections conducted under authority of 44 U.S.C. 2904 and 2906. (n...
5 CFR 297.401 - Conditions of disclosure.
Code of Federal Regulations, 2010 CFR
2010-01-01
... with advance adequate written assurance that the record will be used solely as a statistical research... records; and (ii) Certification that the records will be used only for statistical purposes. (2) These... information from records released for statistical purposes, the system manager will reasonably ensure that the...
Application of up-sampling and resolution scaling to Fresnel reconstruction of digital holograms.
Williams, Logan A; Nehmetallah, Georges; Aylo, Rola; Banerjee, Partha P
2015-02-20
Fresnel transform implementation methods using numerical preprocessing techniques are investigated in this paper. First, it is shown that up-sampling dramatically reduces the minimum reconstruction distance requirements and allows maximal signal recovery by eliminating aliasing artifacts which typically occur at distances much less than the Rayleigh range of the object. Second, zero-padding is employed to arbitrarily scale numerical resolution for the purpose of resolution matching multiple holograms, where each hologram is recorded using dissimilar geometric or illumination parameters. Such preprocessing yields numerical resolution scaling at any distance. Both techniques are extensively illustrated using experimental results.
Optimizing Vowel Formant Measurements in Four Acoustic Analysis Systems for Diverse Speaker Groups
Derdemezis, Ekaterini; Kent, Ray D.; Fourakis, Marios; Reinicke, Emily L.; Bolt, Daniel M.
2016-01-01
Purpose This study systematically assessed the effects of select linear predictive coding (LPC) analysis parameter manipulations on vowel formant measurements for diverse speaker groups using 4 trademarked Speech Acoustic Analysis Software Packages (SAASPs): CSL, Praat, TF32, and WaveSurfer. Method Productions of 4 words containing the corner vowels were recorded from 4 speaker groups with typical development (male and female adults and male and female children) and 4 speaker groups with Down syndrome (male and female adults and male and female children). Formant frequencies were determined from manual measurements using a consensus analysis procedure to establish formant reference values, and from the 4 SAASPs (using both the default analysis parameters and with adjustments or manipulations to select parameters). Smaller differences between values obtained from the SAASPs and the consensus analysis implied more optimal analysis parameter settings. Results Manipulations of default analysis parameters in CSL, Praat, and TF32 yielded more accurate formant measurements, though the benefit was not uniform across speaker groups and formants. In WaveSurfer, manipulations did not improve formant measurements. Conclusions The effects of analysis parameter manipulations on accuracy of formant-frequency measurements varied by SAASP, speaker group, and formant. The information from this study helps to guide clinical and research applications of SAASPs. PMID:26501214
Code of Federal Regulations, 2014 CFR
2014-07-01
... REPORTING OCCUPATIONAL INJURIES AND ILLNESSES Purpose § 1904.0 Purpose. The purpose of this rule (Part 1904) is to require employers to record and report work-related fatalities, injuries and illnesses. Note to § 1904.0: Recording or reporting a work-related injury, illness, or fatality does not mean that the...
Code of Federal Regulations, 2012 CFR
2012-07-01
... REPORTING OCCUPATIONAL INJURIES AND ILLNESSES Purpose § 1904.0 Purpose. The purpose of this rule (Part 1904) is to require employers to record and report work-related fatalities, injuries and illnesses. Note to § 1904.0: Recording or reporting a work-related injury, illness, or fatality does not mean that the...
Systems for monitoring and digitally recording water-quality parameters
Smoot, George F.; Blakey, James F.
1966-01-01
Digital recording of water-quality parameters is a link in the automated data collection and processing system of the U.S. Geological Survey. The monitoring and digital recording systems adopted by the Geological Survey, while punching all measurements on a standard paper tape, provide a choice of compatible components to construct a system to meet specific physical problems and data needs. As many as 10 parameters can be recorded by an Instrument, with the only limiting criterion being that measurements are expressed as electrical signals.
77 FR 29596 - Privacy Act of 1974; Revision and Republication of Systems of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-18
...-based media storage. B. Complete Systems of Records A report of this system of records has been provided... address: Hotline Contract Officer, Office of Communications, Consumer Product Safety Commission, 4330 East... 8101. Purpose(s): Information in these records is used by the Ethics Counselor in making a...
Computer-assisted image processing to detect spores from the fungus Pandora neoaphidis.
Korsnes, Reinert; Westrum, Karin; Fløistad, Erling; Klingen, Ingeborg
2016-01-01
This contribution demonstrates an example of experimental automatic image analysis to detect spores prepared on microscope slides derived from trapping. The application is to monitor aerial spore counts of the entomopathogenic fungus Pandora neoaphidis which may serve as a biological control agent for aphids. Automatic detection of such spores can therefore play a role in plant protection. The present approach for such detection is a modification of traditional manual microscopy of prepared slides, where autonomous image recording precedes computerised image analysis. The purpose of the present image analysis is to support human visual inspection of imagery data - not to replace it. The workflow has three components:•Preparation of slides for microscopy.•Image recording.•Computerised image processing where the initial part is, as usual, segmentation depending on the actual data product. Then comes identification of blobs, calculation of principal axes of blobs, symmetry operations and projection on a three parameter egg shape space.
Probabilistic seismic demand analysis using advanced ground motion intensity measures
Tothong, P.; Luco, N.
2007-01-01
One of the objectives in performance-based earthquake engineering is to quantify the seismic reliability of a structure at a site. For that purpose, probabilistic seismic demand analysis (PSDA) is used as a tool to estimate the mean annual frequency of exceeding a specified value of a structural demand parameter (e.g. interstorey drift). This paper compares and contrasts the use, in PSDA, of certain advanced scalar versus vector and conventional scalar ground motion intensity measures (IMs). One of the benefits of using a well-chosen IM is that more accurate evaluations of seismic performance are achieved without the need to perform detailed ground motion record selection for the nonlinear dynamic structural analyses involved in PSDA (e.g. record selection with respect to seismic parameters such as earthquake magnitude, source-to-site distance, and ground motion epsilon). For structural demands that are dominated by a first mode of vibration, using inelastic spectral displacement (Sdi) can be advantageous relative to the conventionally used elastic spectral acceleration (Sa) and the vector IM consisting of Sa and epsilon (??). This paper demonstrates that this is true for ordinary and for near-source pulse-like earthquake records. The latter ground motions cannot be adequately characterized by either Sa alone or the vector of Sa and ??. For structural demands with significant higher-mode contributions (under either of the two types of ground motions), even Sdi (alone) is not sufficient, so an advanced scalar IM that additionally incorporates higher modes is used.
A new real-time tsunami detection algorithm
NASA Astrophysics Data System (ADS)
Chierici, F.; Embriaco, D.; Pignagnoli, L.
2016-12-01
Real-time tsunami detection algorithms play a key role in any Tsunami Early Warning System. We have developed a new algorithm for tsunami detection based on the real-time tide removal and real-time band-pass filtering of sea-bed pressure recordings. The algorithm greatly increases the tsunami detection probability, shortens the detection delay and enhances detection reliability, at low computational cost. The algorithm is designed to be used also in autonomous early warning systems with a set of input parameters and procedures which can be reconfigured in real time. We have also developed a methodology based on Monte Carlo simulations to test the tsunami detection algorithms. The algorithm performance is estimated by defining and evaluating statistical parameters, namely the detection probability, the detection delay, which are functions of the tsunami amplitude and wavelength, and the occurring rate of false alarms. Pressure data sets acquired by Bottom Pressure Recorders in different locations and environmental conditions have been used in order to consider real working scenarios in the test. We also present an application of the algorithm to the tsunami event which occurred at Haida Gwaii on October 28th, 2012 using data recorded by the Bullseye underwater node of Ocean Networks Canada. The algorithm successfully ran for test purpose in year-long missions onboard the GEOSTAR stand-alone multidisciplinary abyssal observatory, deployed in the Gulf of Cadiz during the EC project NEAREST and on NEMO-SN1 cabled observatory deployed in the Western Ionian Sea, operational node of the European research infrastructure EMSO.
78 FR 78512 - Privacy Act of 1974, as Amended; System of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-26
... Purpose(s): The purpose of this system of records is to establish a manual and electronic database that..., identity theft or fraud, or harm to the security or integrity of this system or other systems or programs...
32 CFR Appendix C to Part 806b - DoD ‘Blanket Routine Uses’
Code of Federal Regulations, 2012 CFR
2012-07-01
... the Office of Personnel Management Routine Use A record from a system of records subject to the... as a routine use to the General Services Administration (GSA) for the purpose of records management... the purpose of records management inspections conducted under authority of 44 U.S.C. 2904 and 2906. m...
Autonomic nervous system responses to sweet taste: evidence for habituation rather than pleasure.
Leterme, A; Brun, L; Dittmar, A; Robin, O
2008-03-18
Previous recordings of the variations of autonomic nervous system (ANS) parameters associated with each primary taste (sweet, salty, sour and bitter) showed that sweet taste induced very weak ANS responses, in the same range or weaker than responses evoked by mineral water. The purpose of this study was then to determine whether this weak ANS activation reflects the pleasant hedonic valence of sweet or the habituation of the organism to this innate-accepted taste. Twenty healthy volunteer subjects (8 males and 12 females, mean age=22.85 years) participated in the experiment. Taste stimuli were a solution of 0.3 M sucrose and three sweet flavours (orange juice, coke, lemonade) as "pleasant" sweet stimuli, and a solution of 0.15 M NaCl as an "unpleasant" stimulus. "Evian" mineral water served as the diluent and as a neutral stimulus. Throughout the test, five ANS parameters (skin potential and skin resistance, skin blood flow and skin temperature, instantaneous heart rate) were simultaneously and continuously recorded. After they had tasted each solution, subjects filled out a questionnaire in which they had to evaluate the hedonic dimension and the sweet intensity of each gustative stimulus. The lack of correlation between the mean hedonic scores associated with the four sweet stimuli and the mean values of the autonomic parameter variations tends to indicate that the weak ANS responses induced by the sweet gustative stimuli rather reflect the habituation of the organism to sweet taste than a gradation in sensory pleasure.
Gudelj, Ines; Babić, Vesna; Milat, Sanja; Čavala, Marijana; Zagorac, Siniša; Katić, Ratko
2015-07-01
The basic aim of this research was to determine the differences of kinematic parameters in two qualitatively different groups of young pole vaulters. With this purpose, a research was conducted in which the video records from a competition were acquired. The sample of entities (N = 71) consisted of successful vaults of 30 pole vaulters, whose attempts were recorded at the European Junior Championship in Novi Sad, held on 23-26th July 2009. The examinees performed the vaults as a part of the elimination competition for the finals, and during the final part of the competition. The age of examinees was from 17 to 19 years, and the span of their best results was from 4.70 to 5.30 meters. The kinematic analysis was conducted according to the standards of APAS procedure (Ariel Performance Analysis System, USA), determining 25 kinematic variables necessary for further analysis. The entities (vaults) were divided into two categories (qualitative classes) based on the expert knowledge. Group 1 consisted of successful vaults up to 4.90 m (N = 46), while group 2 consisted of successful vaults whose height was more than 4.90 m (N = 25). The discrimination analysis determined the parameters differentiating the vaults of different quantitative classes. Also, it was confirmed that the result efficiency in pole vault was primarily determined by the variables defined by motor abilities, as well as the indicators determining the vault performance technique.
10 CFR 600.340 - Purpose of reports and records.
Code of Federal Regulations, 2010 CFR
2010-01-01
... and reporting financial and program performance and for records retention. ... 10 Energy 4 2010-01-01 2010-01-01 false Purpose of reports and records. 600.340 Section 600.340 Energy DEPARTMENT OF ENERGY (CONTINUED) ASSISTANCE REGULATIONS FINANCIAL ASSISTANCE RULES Administrative...
Lourenço, Elizabete Captivo; Almeida, Juliana Cardoso; Famadas, Kátia Maria
2016-11-01
The family Streblidae consists of obligate hematophagous ectoparasites of bats. The richness of Streblidae may be affected by environmental and host-related variables, collection methods, and sampling effort. The purposes of this study were to list the Streblidae species recorded in Brazil, verify their distribution in the Brazilian biomes and states, and pinpoint the parameters that favored the greatest richness. Through queries in online databases and libraries, 86 publications were found containing records of 83 species in 24 genera. The state with the largest number of publications was São Paulo and Federal District presented the highest richness of Streblidae. The largest number of records of Streblidae species was in Cerrado biome. The meta-analyses utilizing 26 Brazilian inventories showed that the richness of Streblidae was positively correlated with the number of flies and richness and abundance of Phyllostomidae. We hope that the results of this study will contribute to a better understanding of the distribution of research on Streblidae in Brazil and confirming the specificity between Streblidae and Phyllostomidae.
Yong, Jennifer R; Silder, Amy; Montgomery, Kate L; Fredericson, Michael; Delp, Scott L
2018-05-18
Tibial stress fractures are a common and debilitating injury that occur in distance runners. Runners may be able to decrease tibial stress fracture risk by adopting a running pattern that reduces biomechanical parameters associated with a history of tibial stress fracture. The purpose of this study was to test the hypothesis that converting to a forefoot striking pattern or increasing cadence without focusing on changing foot strike type would reduce injury risk parameters in recreational runners. Running kinematics, ground reaction forces and tibial accelerations were recorded from seventeen healthy, habitual rearfoot striking runners while running in their natural running pattern and after two acute retraining conditions: (1) converting to forefoot striking without focusing on cadence and (2) increasing cadence without focusing on foot strike. We found that converting to forefoot striking decreased two risk factors for tibial stress fracture: average and peak loading rates. Increasing cadence decreased one risk factor: peak hip adduction angle. Our results demonstrate that acute adaptation to forefoot striking reduces different injury risk parameters than acute adaptation to increased cadence and suggest that both modifications may reduce the risk of tibial stress fractures. Copyright © 2018 Elsevier Ltd. All rights reserved.
Crackle analysis for chest auscultation and comparison with high-resolution CT findings.
Kawamura, Takeo; Matsumoto, Tsuneo; Tanaka, Nobuyuki; Kido, Shoji; Jiang, Zhongwei; Matsunaga, Naofumi
2003-01-01
The purpose of our study was to clarify the correlation between respiratory sounds and the high-resolution CT (HRCT) findings of lung diseases. Respiratory sounds were recorded using a stethoscope in 41 patients with crackles. All had undergone inspiratory and expiratory CT. Subjects included 18 patients with interstitial pneumonia and 23 without interstitial pneumonia. Two parameters, two-cycle duration (2CD) and initial deflection width (IDW) of the "crackle," were induced by time-expanded waveform analysis. Two radiologists independently assessed 11 HRCT findings. An evaluation was carried out to determine whether there was a significant difference in the two parameters between the presence and absence of each HRCT finding. The two parameters of crackles were significantly shorter in the interstitial pneumonia group than the non-interstitial pneumonia group. Ground-glass opacity, honeycombing, lung volume reduction, traction bronchiectasis, centrilobular nodules, emphysematous change, and attenuation and volume change between inspiratory and expiratory CT were correlated with one or two parameters in all patients, whereas the other three findings were not. Among the interstitial pneumonia group, traction bronchiectasis, emphysematous change, and attenuation and volume change between inspiratory and expiratory CT were significantly correlated with one or two parameters. Abnormal respiratory sounds were correlated with some HRCT findings.
Quantitative fluorescence angiography for neurosurgical interventions.
Weichelt, Claudia; Duscha, Philipp; Steinmeier, Ralf; Meyer, Tobias; Kuß, Julia; Cimalla, Peter; Kirsch, Matthias; Sobottka, Stephan B; Koch, Edmund; Schackert, Gabriele; Morgenstern, Ute
2013-06-01
Present methods for quantitative measurement of cerebral perfusion during neurosurgical operations require additional technology for measurement, data acquisition, and processing. This study used conventional fluorescence video angiography--as an established method to visualize blood flow in brain vessels--enhanced by a quantifying perfusion software tool. For these purposes, the fluorescence dye indocyanine green is given intravenously, and after activation by a near-infrared light source the fluorescence signal is recorded. Video data are analyzed by software algorithms to allow quantification of the blood flow. Additionally, perfusion is measured intraoperatively by a reference system. Furthermore, comparing reference measurements using a flow phantom were performed to verify the quantitative blood flow results of the software and to validate the software algorithm. Analysis of intraoperative video data provides characteristic biological parameters. These parameters were implemented in the special flow phantom for experimental validation of the developed software algorithms. Furthermore, various factors that influence the determination of perfusion parameters were analyzed by means of mathematical simulation. Comparing patient measurement, phantom experiment, and computer simulation under certain conditions (variable frame rate, vessel diameter, etc.), the results of the software algorithms are within the range of parameter accuracy of the reference methods. Therefore, the software algorithm for calculating cortical perfusion parameters from video data presents a helpful intraoperative tool without complex additional measurement technology.
Comparison of a single-channel EEG sleep study to polysomnography
Lucey, Brendan P.; McLeland, Jennifer S.; Toedebusch, Cristina D.; Boyd, Jill; Morris, John C.; Landsness, Eric C.; Yamada, Kelvin; Holtzman, David M.
2016-01-01
Summary An accurate home sleep study to assess electroencephalography (EEG)-based sleep stages and EEG power would be advantageous for both clinical and research purposes, such as for longitudinal studies measuring changes in sleep stages over time. The purpose of this study was to compare sleep scoring of a single-channel EEG recorded simultaneously on the forehead against attended polysomnography. Participants were recruited from both a clinical sleep center and a longitudinal research study investigating cognitively-normal aging and Alzheimer's disease. Analysis for overall epoch-by-epoch agreement found strong and substantial agreement between the single-channel EEG compared to polysomnography (kappa=0.67). Slow wave activity in the frontal regions was also similar when comparing the single-channel EEG device to polysomnography. As expected, stage N1 showed poor agreement (sensitivity 0.2) due to lack of occipital electrodes. Other sleep parameters such as sleep latency and REM onset latency had decreased agreement. Participants with disrupted sleep consolidation, such as from obstructive sleep apnea, also had poor agreement. We suspect that disagreement in sleep parameters between the single-channel EEG and polysomnography is partially due to altered waveform morphology and/or poorer signal quality in the single-channel derivation. Our results show that single-channel EEG provides comparable results to polysomnography in assessing REM, combined stages N2 and N3 sleep, and several other parameters including frontal slow wave activity. The data establish that single-channel EEG can be a useful research tool. PMID:27252090
18 CFR 3b.225 - Written consent for disclosure.
Code of Federal Regulations, 2010 CFR
2010-04-01
... as a statistical research or reporting record, and the record is to be transferred in a form that is... for statistical purposes. In addition to stripping personally identifying information from records released for statistical purposes, the system manager will ensure that the identity of the individual...
Code of Federal Regulations, 2010 CFR
2010-10-01
... control of the NTSB pursuant to Federal law or in connection with the transaction of public business... purposes ordered by a court referral to potential employers, and for security clearance; Statistical record means a record in a system of records maintained for statistical research or reporting purposes only and...
Underground coal mine instrumentation and test
NASA Technical Reports Server (NTRS)
Burchill, R. F.; Waldron, W. D.
1976-01-01
The need to evaluate mechanical performance of mine tools and to obtain test performance data from candidate systems dictate that an engineering data recording system be built. Because of the wide range of test parameters which would be evaluated, a general purpose data gathering system was designed and assembled to permit maximum versatility. A primary objective of this program was to provide a specific operating evaluation of a longwall mining machine vibration response under normal operating conditions. A number of mines were visited and a candidate for test evaluation was selected, based upon management cooperation, machine suitability, and mine conditions. Actual mine testing took place in a West Virginia mine.
42 CFR 2.3 - Purpose and effect.
Code of Federal Regulations, 2010 CFR
2010-10-01
... ALCOHOL AND DRUG ABUSE PATIENT RECORDS Introduction § 2.3 Purpose and effect. (a) Purpose. Under the... use of alcohol and drug abuse patient records which are maintained in connection with the performance of any federally assisted alcohol and drug abuse program. The regulations specify: (1) Definitions...
42 CFR 2.3 - Purpose and effect.
Code of Federal Regulations, 2014 CFR
2014-10-01
... ALCOHOL AND DRUG ABUSE PATIENT RECORDS Introduction § 2.3 Purpose and effect. (a) Purpose. Under the... use of alcohol and drug abuse patient records which are maintained in connection with the performance of any federally assisted alcohol and drug abuse program. The regulations specify: (1) Definitions...
42 CFR 2.3 - Purpose and effect.
Code of Federal Regulations, 2013 CFR
2013-10-01
... ALCOHOL AND DRUG ABUSE PATIENT RECORDS Introduction § 2.3 Purpose and effect. (a) Purpose. Under the... use of alcohol and drug abuse patient records which are maintained in connection with the performance of any federally assisted alcohol and drug abuse program. The regulations specify: (1) Definitions...
42 CFR 2.3 - Purpose and effect.
Code of Federal Regulations, 2012 CFR
2012-10-01
... ALCOHOL AND DRUG ABUSE PATIENT RECORDS Introduction § 2.3 Purpose and effect. (a) Purpose. Under the... use of alcohol and drug abuse patient records which are maintained in connection with the performance of any federally assisted alcohol and drug abuse program. The regulations specify: (1) Definitions...
42 CFR 2.3 - Purpose and effect.
Code of Federal Regulations, 2011 CFR
2011-10-01
... ALCOHOL AND DRUG ABUSE PATIENT RECORDS Introduction § 2.3 Purpose and effect. (a) Purpose. Under the... use of alcohol and drug abuse patient records which are maintained in connection with the performance of any federally assisted alcohol and drug abuse program. The regulations specify: (1) Definitions...
Subjective scaling of spatial room acoustic parameters influenced by visual environmental cues
Valente, Daniel L.; Braasch, Jonas
2010-01-01
Although there have been numerous studies investigating subjective spatial impression in rooms, only a few of those studies have addressed the influence of visual cues on the judgment of auditory measures. In the psychophysical study presented here, video footage of five solo music∕speech performers was shown for four different listening positions within a general-purpose space. The videos were presented in addition to the acoustic signals, which were auralized using binaural room impulse responses (BRIR) that were recorded in the same general-purpose space. The participants were asked to adjust the direct-to-reverberant energy ratio (D∕R ratio) of the BRIR according to their expectation considering the visual cues. They were also directed to rate the apparent source width (ASW) and listener envelopment (LEV) for each condition. Visual cues generated by changing the sound-source position in the multi-purpose space, as well as the makeup of the sound stimuli affected the judgment of spatial impression. Participants also scaled the direct-to-reverberant energy ratio with greater direct sound energy than was measured in the acoustical environment. PMID:20968367
Evaluation of Anterior Segment Parameters in Obesity
Uzun, Feyzahan; Karaca, Emine Esra; Kalaycı, Mustafa
2015-01-01
Purpose To investigate anterior segment parameters in obese patients in comparison to healthy individuals. Methods Thirty-four obese subjects and 34 age-sex-matched healthy subjects were enrolled in this prospective cross-sectional study. Ophthalmological examinations including intraocular pressure (IOP), central corneal thickness (CCT), anterior chamber depth (ACD), anterior chamber volume (ACV), anterior chamber angle (ACA), and axial length (AL) measurements were performed on each subject. Height and weight of all subjects were recorded and body mass index (BMI) was calculated. Results IOP was significantly higher in the obese group (p = 0.003). The mean ACD in obese subjects was significantly lower than that in control subjects (p = 0.036). AL, ACV, ACA and CCT were not significantly different between the groups. There was a positive correlation between BMI and IOP (r = 0.404, p < 0.001). ACD and ACA were negatively correlated with BMI. Conclusions IOP was significantly higher and ACD was significantly lower in obese subjects. AL, ACV, ACA and CCT were not significantly different between the groups. The impact of obesity on anterior chamber parameters should be further investigated. PMID:26240505
An alternative respiratory sounds classification system utilizing artificial neural networks.
Oweis, Rami J; Abdulhay, Enas W; Khayal, Amer; Awad, Areen
2015-01-01
Computerized lung sound analysis involves recording lung sound via an electronic device, followed by computer analysis and classification based on specific signal characteristics as non-linearity and nonstationarity caused by air turbulence. An automatic analysis is necessary to avoid dependence on expert skills. This work revolves around exploiting autocorrelation in the feature extraction stage. All process stages were implemented in MATLAB. The classification process was performed comparatively using both artificial neural networks (ANNs) and adaptive neuro-fuzzy inference systems (ANFIS) toolboxes. The methods have been applied to 10 different respiratory sounds for classification. The ANN was superior to the ANFIS system and returned superior performance parameters. Its accuracy, specificity, and sensitivity were 98.6%, 100%, and 97.8%, respectively. The obtained parameters showed superiority to many recent approaches. The promising proposed method is an efficient fast tool for the intended purpose as manifested in the performance parameters, specifically, accuracy, specificity, and sensitivity. Furthermore, it may be added that utilizing the autocorrelation function in the feature extraction in such applications results in enhanced performance and avoids undesired computation complexities compared to other techniques.
20 CFR 903.1 - Purpose and scope of regulations.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 20 Employees' Benefits 3 2011-04-01 2011-04-01 false Purpose and scope of regulations. 903.1 Section 903.1 Employees' Benefits JOINT BOARD FOR THE ENROLLMENT OF ACTUARIES ACCESS TO RECORDS Records... all records maintained by the Joint Board for the Enrollment of Actuaries (Joint Board) which are...
20 CFR 903.1 - Purpose and scope of regulations.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 20 Employees' Benefits 4 2013-04-01 2013-04-01 false Purpose and scope of regulations. 903.1 Section 903.1 Employees' Benefits JOINT BOARD FOR THE ENROLLMENT OF ACTUARIES ACCESS TO RECORDS Records... all records maintained by the Joint Board for the Enrollment of Actuaries (Joint Board) which are...
20 CFR 903.1 - Purpose and scope of regulations.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 20 Employees' Benefits 4 2014-04-01 2014-04-01 false Purpose and scope of regulations. 903.1 Section 903.1 Employees' Benefits JOINT BOARD FOR THE ENROLLMENT OF ACTUARIES ACCESS TO RECORDS Records... all records maintained by the Joint Board for the Enrollment of Actuaries (Joint Board) which are...
20 CFR 903.1 - Purpose and scope of regulations.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 20 Employees' Benefits 4 2012-04-01 2012-04-01 false Purpose and scope of regulations. 903.1 Section 903.1 Employees' Benefits JOINT BOARD FOR THE ENROLLMENT OF ACTUARIES ACCESS TO RECORDS Records... all records maintained by the Joint Board for the Enrollment of Actuaries (Joint Board) which are...
20 CFR 903.1 - Purpose and scope of regulations.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Purpose and scope of regulations. 903.1 Section 903.1 Employees' Benefits JOINT BOARD FOR THE ENROLLMENT OF ACTUARIES ACCESS TO RECORDS Records... all records maintained by the Joint Board for the Enrollment of Actuaries (Joint Board) which are...
Code of Federal Regulations, 2014 CFR
2014-07-01
... AND VIDEO RECORDINGS § 142.1 Purpose. This part provides policy, prescribes procedures, and assigned responsibilities regarding the use of copyrighted sound and video recordings within the Department of Defense. ...
39 CFR 262.1 - Purpose and scope.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 39 Postal Service 1 2011-07-01 2011-07-01 false Purpose and scope. 262.1 Section 262.1 Postal Service UNITED STATES POSTAL SERVICE ORGANIZATION AND ADMINISTRATION RECORDS AND INFORMATION MANAGEMENT DEFINITIONS § 262.1 Purpose and scope. This part contains the official definition of those basic records and...
39 CFR 262.1 - Purpose and scope.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 39 Postal Service 1 2010-07-01 2010-07-01 false Purpose and scope. 262.1 Section 262.1 Postal Service UNITED STATES POSTAL SERVICE ORGANIZATION AND ADMINISTRATION RECORDS AND INFORMATION MANAGEMENT DEFINITIONS § 262.1 Purpose and scope. This part contains the official definition of those basic records and...
39 CFR 262.1 - Purpose and scope.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 39 Postal Service 1 2014-07-01 2014-07-01 false Purpose and scope. 262.1 Section 262.1 Postal Service UNITED STATES POSTAL SERVICE ORGANIZATION AND ADMINISTRATION RECORDS AND INFORMATION MANAGEMENT DEFINITIONS § 262.1 Purpose and scope. This part contains the official definition of those basic records and...
39 CFR 262.1 - Purpose and scope.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 39 Postal Service 1 2013-07-01 2013-07-01 false Purpose and scope. 262.1 Section 262.1 Postal Service UNITED STATES POSTAL SERVICE ORGANIZATION AND ADMINISTRATION RECORDS AND INFORMATION MANAGEMENT DEFINITIONS § 262.1 Purpose and scope. This part contains the official definition of those basic records and...
Effects of System Timing Parameters on Operator Performance in a Personnel Records Task
1981-03-01
work sampling, embedded performance measures, and operator satisfaction ratings) are needed to provide a complete analysis of the effects of the four...HFL-8 l-l/NPRDC-8 1-1 March 1981 EFFECTS OF SYSTEM TIMING PARAMETERS ON OPERATOR PERFORMANCE IN A PERSONNEL RECORDS TASK Robert C. Williges Beverly H...and Subtitle) S. TYPE OF REPORT & PERIOD COVERED EFFECTS OF SYSTEM TIMING PARAMETERS ON OPERATOR PERFORMANCE IN A PERSONNEL RECORDS TASK Final
Spatial-structural analysis of leafless woody riparian vegetation for hydraulic considerations
NASA Astrophysics Data System (ADS)
Weissteiner, Clemens; Jalonen, Johanna; Järvelä, Juha; Rauch, Hans Peter
2013-04-01
Woody riparian vegetation is a vital element of riverine environments. On one hand woody riparian vegetation has to be taken into account from a civil engineering point of view due to boundary shear stress and vegetation drag. On the other hand it has to be considered from a river ecological point of view due to shadowing effects and as a source of organic material for aquatic habitats. In hydrodynamic and hydro-ecological studies the effects of woody riparian vegetation on flow patterns are usually investigated on a very detailed level. On the contrary vegetation elements and their spatial patterns are generally analysed and discussed on the basis of an integral approach measuring for example basal diameters, heights and projected plant areas. For a better understanding of the influence of woody riparian vegetation on turbulent flow and on river ecology, it is essential to record and analyse plant data sets on the same level of quality as for hydrodynamic or hydro-ecologic purposes. As a result of the same scale of the analysis it is possible to incorporate riparian vegetation as a sub-model in the hydraulic analysis. For plant structural components, such as branches on different topological levels it is crucial to record plant geometrical parameters describing the habitus of the plant on branch level. An exact 3D geometrical model of real plants allows for an extraction of various spatial-structural plant parameters. In addition, allometric relationships help to summarize and describe plant traits of riparian vegetation. This paper focuses on the spatial-structural composition of leafless riparia woddy vegetation. Structural and spatial analyses determine detailed geometric properties of the structural components of the plants. Geometrical and topological parameters were recorded with an electro-magnetic scanning device. In total, 23 plants (willows, alders and birches) were analysed in the study. Data were recorded on branch level, which allowed for the development of a 3D geometric plant model. The results are expected to improve knowledge on how the architectural system and allometric relationships of the plants relate to ecological and hydrodynamic properties.
28 CFR 904.1 - Purpose and authority.
Code of Federal Regulations, 2011 CFR
2011-07-01
... HISTORY RECORD SCREENING STANDARDS § 904.1 Purpose and authority. Pursuant to the National Crime..., Article IV (c), the Compact Council hereby establishes record screening standards for criminal history...
28 CFR 904.1 - Purpose and authority.
Code of Federal Regulations, 2014 CFR
2014-07-01
... HISTORY RECORD SCREENING STANDARDS § 904.1 Purpose and authority. Pursuant to the National Crime..., Article IV (c), the Compact Council hereby establishes record screening standards for criminal history...
28 CFR 904.1 - Purpose and authority.
Code of Federal Regulations, 2013 CFR
2013-07-01
... HISTORY RECORD SCREENING STANDARDS § 904.1 Purpose and authority. Pursuant to the National Crime..., Article IV (c), the Compact Council hereby establishes record screening standards for criminal history...
28 CFR 904.1 - Purpose and authority.
Code of Federal Regulations, 2012 CFR
2012-07-01
... HISTORY RECORD SCREENING STANDARDS § 904.1 Purpose and authority. Pursuant to the National Crime..., Article IV (c), the Compact Council hereby establishes record screening standards for criminal history...
28 CFR 904.1 - Purpose and authority.
Code of Federal Regulations, 2010 CFR
2010-07-01
... HISTORY RECORD SCREENING STANDARDS § 904.1 Purpose and authority. Pursuant to the National Crime..., Article IV (c), the Compact Council hereby establishes record screening standards for criminal history...
Morisawa, Tomoyuki; Takahashi, Tetsuya; Sasanuma, Naoki; Mabuchi, Satoshi; Takeda, Kenta; Hori, Naoto; Ohashi, Naotsugu; Ide, Takeshi; Domen, Kazuhisa; Nishi, Shinichi
2017-02-01
[Purpose] The purpose of this study was to clarify the effects of passive exercise of the lower limbs and trunk (PELT) in ICU patients after cardiovascular surgery with decreased bowel motility. [Subjects and Methods] Ten ICU patients with clinically-apparent decreased bowel motility during the period of April to July 2016 were enrolled this study. Bowel sounds (BS) for 5 minutes at rest and 5 minutes after PELT were recorded through an electronic stethoscope. A frequency analysis was performed and the BS before and after PELT were compared. In addition, the percent change in BS before and after PELT was determined, and the relationship between the percent change in BS and individual parameters (invasiveness of surgery, inflammation, nutrition, renal function) was examined. [Results] Average BS (integral value) for 5 minutes before and after PELT were 63.1 ± 41.3 mVsec and 115.0 ± 57.8 mVsec, respectively; therefore, BS was significantly increased by PELT. When compared to patients at rest, a significant increase was found 0-4 minutes after PELT. None of the individual parameters was significantly correlated with the percent change. [Conclusion] PELT can increase the bowel motility of ICU patients with decreased bowel motility.
27 CFR 40.232 - Experimental purposes.
Code of Federal Regulations, 2010 CFR
2010-04-01
..., DEPARTMENT OF THE TREASURY (CONTINUED) TOBACCO MANUFACTURE OF TOBACCO PRODUCTS, CIGARETTE PAPERS AND TUBES... after their use for experimental purposes. (e) Record of use. In addition to the records prescribed by...
27 CFR 40.232 - Experimental purposes.
Code of Federal Regulations, 2011 CFR
2011-04-01
..., DEPARTMENT OF THE TREASURY (CONTINUED) TOBACCO MANUFACTURE OF TOBACCO PRODUCTS, CIGARETTE PAPERS AND TUBES... after their use for experimental purposes. (e) Record of use. In addition to the records prescribed by...
27 CFR 40.232 - Experimental purposes.
Code of Federal Regulations, 2014 CFR
2014-04-01
..., DEPARTMENT OF THE TREASURY (CONTINUED) TOBACCO MANUFACTURE OF TOBACCO PRODUCTS, CIGARETTE PAPERS AND TUBES... after their use for experimental purposes. (e) Record of use. In addition to the records prescribed by...
27 CFR 40.232 - Experimental purposes.
Code of Federal Regulations, 2013 CFR
2013-04-01
..., DEPARTMENT OF THE TREASURY (CONTINUED) TOBACCO MANUFACTURE OF TOBACCO PRODUCTS, CIGARETTE PAPERS AND TUBES... after their use for experimental purposes. (e) Record of use. In addition to the records prescribed by...
Khanduja, Sumeet; Sampangi, Raju; Hemlatha, B C; Singh, Satvir; Lall, Ashish
2018-01-01
The purpose of this study is to describe the use of commercial digital single light reflex (DSLR) for vitreoretinal surgery recording and compare it to standard 3-chip charged coupling device (CCD) camera. Simultaneous recording was done using Sony A7s2 camera and Sony high-definition 3-chip camera attached to each side of the microscope. The videos recorded from both the camera systems were edited and sequences of similar time frames were selected. Three sequences that selected for evaluation were (a) anterior segment surgery, (b) surgery under direct viewing system, and (c) surgery under indirect wide-angle viewing system. The videos of each sequence were evaluated and rated on a scale of 0-10 for color, contrast, and overall quality Results: Most results were rated either 8/10 or 9/10 for both the cameras. A noninferiority analysis by comparing mean scores of DSLR camera versus CCD camera was performed and P values were obtained. The mean scores of the two cameras were comparable for each other on all parameters assessed in the different videos except of color and contrast in posterior pole view and color on wide-angle view, which were rated significantly higher (better) in DSLR camera. Commercial DSLRs are an affordable low-cost alternative for vitreoretinal surgery recording and may be used for documentation and teaching.
SU-E-T-473: A Patient-Specific QC Paradigm Based On Trajectory Log Files and DICOM Plan Files
DOE Office of Scientific and Technical Information (OSTI.GOV)
DeMarco, J; McCloskey, S; Low, D
Purpose: To evaluate a remote QC tool for monitoring treatment machine parameters and treatment workflow. Methods: The Varian TrueBeamTM linear accelerator is a digital machine that records machine axis parameters and MLC leaf positions as a function of delivered monitor unit or control point. This information is saved to a binary trajectory log file for every treatment or imaging field in the patient treatment session. A MATLAB analysis routine was developed to parse the trajectory log files for a given patient, compare the expected versus actual machine and MLC positions as well as perform a cross-comparison with the DICOM-RT planmore » file exported from the treatment planning system. The parsing routine sorts the trajectory log files based on the time and date stamp and generates a sequential report file listing treatment parameters and provides a match relative to the DICOM-RT plan file. Results: The trajectory log parsing-routine was compared against a standard record and verify listing for patients undergoing initial IMRT dosimetry verification and weekly and final chart QC. The complete treatment course was independently verified for 10 patients of varying treatment site and a total of 1267 treatment fields were evaluated including pre-treatment imaging fields where applicable. In the context of IMRT plan verification, eight prostate SBRT plans with 4-arcs per plan were evaluated based on expected versus actual machine axis parameters. The average value for the maximum RMS MLC error was 0.067±0.001mm and 0.066±0.002mm for leaf bank A and B respectively. Conclusion: A real-time QC analysis program was tested using trajectory log files and DICOM-RT plan files. The parsing routine is efficient and able to evaluate all relevant machine axis parameters during a patient treatment course including MLC leaf positions and table positions at time of image acquisition and during treatment.« less
49 CFR 19.50 - Purpose of reports and records.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 1 2010-10-01 2010-10-01 false Purpose of reports and records. 19.50 Section 19.50 Transportation Office of the Secretary of Transportation UNIFORM ADMINISTRATIVE REQUIREMENTS FOR GRANTS AND AGREEMENTS WITH INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Reports and Records...
49 CFR 19.50 - Purpose of reports and records.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 1 2011-10-01 2011-10-01 false Purpose of reports and records. 19.50 Section 19.50 Transportation Office of the Secretary of Transportation UNIFORM ADMINISTRATIVE REQUIREMENTS FOR GRANTS AND AGREEMENTS WITH INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Reports and Records...
Apparatus Characterizes Transient Voltages in Real Time
NASA Technical Reports Server (NTRS)
Medelius, Pedro
2005-01-01
The figure shows a prototype of a relatively inexpensive electronic monitoring apparatus that measures and records selected parameters of lightning-induced transient voltages on communication and power cables. The selected parameters, listed below, are those most relevant to the ability of lightning-induced transients to damage electronic equipment. This apparatus bridges a gap between some traditional transient-voltage recorders that record complete waveforms and other traditional transient-voltage recorders that record only peak values: By recording the most relevant parameters and only those parameters this apparatus yields more useful information than does a traditional peak-value (only) recorder while imposing much smaller data-storage and data-transmission burdens than does a traditional complete-waveform recorder. Also, relative to a complete-waveform recorder, this apparatus is more reliable and can be built at lower cost because it contains fewer electronic components. The transients generated by sources other than lightning tend to have frequency components well below 1 MHz. Most commercial transient recorders can detect and record such transients, but cannot respond rapidly enough for recording lightning-induced transient voltage peaks, which can rise from 10 to 90 percent of maximum amplitude in a fraction of a microsecond. Moreover, commercial transient recorders cannot rearm themselves rapidly enough to respond to the multiple transients that occur within milliseconds of each other on some lightning strikes. One transient recorder, designed for Kennedy Space Center earlier [ Fast Transient-Voltage Recorder (KSC- 11991), NASA Tech Briefs, Vol. 23, No. 10, page 6a (October 1999)], is capable of sampling transient voltages at peak values up to 50 V in four channels at a rate of 20 MHz. That recorder contains a trigger circuit that continuously compares the amplitudes of the signals on four channels to a preset triggering threshold. When a trigger signal is received, a volatile memory is filled with data for a total time of 200 ms. After the data are transferred to nonvolatile memory, the recorder rearms itself within 400 ms to enable recording of subsequent transients. Unfortunately, the recorded data must be retrieved through a serial communication link. Depending on the amount of data recorded, the memory can be filled before retrieval is completed. Although large amounts of data are recorded and retrieved, only a small part of the information (the selected parameters) is usually required. The present transient-voltage recorder provides the required information, without incurring the overhead associated with the recording, storage, and retrieval of complete transient-waveform data. In operation, this apparatus processes transient voltage waveforms in real time to extract and record the selected parameters. An analog-to-digital converter that operates at a speed of as much as 100 mega-samples per second is used to sample a transient waveform. A real-time comparator and peak detector are implemented by use of fast field-programmable gate arrays.
Code of Federal Regulations, 2010 CFR
2010-01-01
... with enforcing criminal or civil laws. (d) Documents exempted. Exemptions will be applied only when... material compiled for law enforcement purposes. 503.2 Section 503.2 Banks and Banking OFFICE OF THRIFT... material compiled for law enforcement purposes. (a) Scope. The Office has established a system of records...
Code of Federal Regulations, 2014 CFR
2014-01-01
... with enforcing criminal or civil laws. (d) Documents exempted. Exemptions will be applied only when... material compiled for law enforcement purposes. 503.2 Section 503.2 Banks and Banking OFFICE OF THRIFT... material compiled for law enforcement purposes. (a) Scope. The Office has established a system of records...
Code of Federal Regulations, 2012 CFR
2012-01-01
... with enforcing criminal or civil laws. (d) Documents exempted. Exemptions will be applied only when... material compiled for law enforcement purposes. 503.2 Section 503.2 Banks and Banking OFFICE OF THRIFT... material compiled for law enforcement purposes. (a) Scope. The Office has established a system of records...
Code of Federal Regulations, 2011 CFR
2011-01-01
... with enforcing criminal or civil laws. (d) Documents exempted. Exemptions will be applied only when... material compiled for law enforcement purposes. 503.2 Section 503.2 Banks and Banking OFFICE OF THRIFT... material compiled for law enforcement purposes. (a) Scope. The Office has established a system of records...
Code of Federal Regulations, 2013 CFR
2013-01-01
... with enforcing criminal or civil laws. (d) Documents exempted. Exemptions will be applied only when... material compiled for law enforcement purposes. 503.2 Section 503.2 Banks and Banking OFFICE OF THRIFT... material compiled for law enforcement purposes. (a) Scope. The Office has established a system of records...
4 CFR 83.1 - Purpose and scope of part.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 4 Accounts 1 2010-01-01 2010-01-01 false Purpose and scope of part. 83.1 Section 83.1 Accounts GOVERNMENT ACCOUNTABILITY OFFICE RECORDS PRIVACY PROCEDURES FOR PERSONNEL RECORDS § 83.1 Purpose and scope of part. This part describes the policy and prescribes the procedures of the U.S. Government...
76 FR 4449 - Privacy Act of 1974; Report of Modified or Altered System of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-25
... for the purpose of assisting the Department's efforts to respond to a suspected or confirmed breach of... returned to submitter. Used between specialty units for research purposes; and for epidemiological... or Altered System of Records Narrative Statement I. Background and Purpose of the System A...
76 FR 4446 - Privacy Act of 1974; Report of Modified or Altered System of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-25
... the information for the purpose of assisting the Department's efforts to respond to a suspected or...--Report of Modified or Altered System of Records Narrative Statement I. Background and Purpose of the... information for the purpose of assisting the Department's efforts to respond to a suspected or confirmed...
40 CFR 60.1850 - What records must I keep for continuously monitored pollutants or parameters?
Code of Federal Regulations, 2010 CFR
2010-07-01
... carbon dioxide, as specified in § 60.1745. (h) Records of calendar dates. Include the calendar date on... continuously monitored pollutants or parameters? 60.1850 Section 60.1850 Protection of Environment... or Before August 30, 1999 Model Rule-Recordkeeping § 60.1850 What records must I keep for...
40 CFR 60.1850 - What records must I keep for continuously monitored pollutants or parameters?
Code of Federal Regulations, 2012 CFR
2012-07-01
... carbon dioxide, as specified in § 60.1745. (h) Records of calendar dates. Include the calendar date on... continuously monitored pollutants or parameters? 60.1850 Section 60.1850 Protection of Environment... or Before August 30, 1999 Model Rule-Recordkeeping § 60.1850 What records must I keep for...
40 CFR 60.1850 - What records must I keep for continuously monitored pollutants or parameters?
Code of Federal Regulations, 2011 CFR
2011-07-01
... carbon dioxide, as specified in § 60.1745. (h) Records of calendar dates. Include the calendar date on... continuously monitored pollutants or parameters? 60.1850 Section 60.1850 Protection of Environment... or Before August 30, 1999 Model Rule-Recordkeeping § 60.1850 What records must I keep for...
40 CFR 60.1850 - What records must I keep for continuously monitored pollutants or parameters?
Code of Federal Regulations, 2013 CFR
2013-07-01
... carbon dioxide, as specified in § 60.1745. (h) Records of calendar dates. Include the calendar date on... continuously monitored pollutants or parameters? 60.1850 Section 60.1850 Protection of Environment... or Before August 30, 1999 Model Rule-Recordkeeping § 60.1850 What records must I keep for...
40 CFR 60.1850 - What records must I keep for continuously monitored pollutants or parameters?
Code of Federal Regulations, 2014 CFR
2014-07-01
... carbon dioxide, as specified in § 60.1745. (h) Records of calendar dates. Include the calendar date on... continuously monitored pollutants or parameters? 60.1850 Section 60.1850 Protection of Environment... or Before August 30, 1999 Model Rule-Recordkeeping § 60.1850 What records must I keep for...
SU-E-P-05: Electronic Brachytherapy: A Physics Perspective On Field Implementation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pai, S; Ayyalasomayajula, S; Lee, S
2015-06-15
Purpose: We want to summarize our experience implementing a successful program of electronic brachytherapy at several dermatology clinics with the help of a cloud based software to help us define the key program parameters and capture physics QA aspects. Optimally developed software helps the physicist in peer review and qualify the physical parameters. Methods: Using the XOFT™ Axxent™ electronic brachytherapy system in conjunction with a cloud-based software, a process was setup to capture and record treatments. It was implemented initially at about 10 sites in California. For dosimetric purposes, the software facilitated storage of the physics parameters of surface applicatorsmore » used in treatment and other source calibration parameters. In addition, the patient prescription, pathology and other setup considerations were input by radiation oncologist and the therapist. This facilitated physics planning of the treatment parameters and also independent check of the dwell time. From 2013–2014, nearly1500 such calculation were completed by a group of physicists. A total of 800 patients with multiple lesions have been treated successfully during this period. The treatment log files have been uploaded and documented in the software which facilitated physics peer review of treatments per the standards in place by AAPM and ACR. Results: The program model was implemented successfully at multiple sites. The cloud based software allowed for proper peer review and compliance of the program at 10 clinical sites. Dosimtery was done on 800 patients and executed in a timely fashion to suit the clinical needs. Accumulated physics data in the software from the clinics allows for robust analysis and future development. Conclusion: Electronic brachytherapy implementation experience from a quality assurance perspective was greatly enhanced by using a cloud based software. The comprehensive database will pave the way for future developments to yield superior physics outcomes.« less
40 CFR 60.1365 - What records must I keep for continuously monitored pollutants or parameters?
Code of Federal Regulations, 2010 CFR
2010-07-01
... diluent gas, document the relationship between oxygen and carbon dioxide, as specified in § 60.1255. (h... continuously monitored pollutants or parameters? 60.1365 Section 60.1365 Protection of Environment... Recordkeeping § 60.1365 What records must I keep for continuously monitored pollutants or parameters? You must...
40 CFR 60.1365 - What records must I keep for continuously monitored pollutants or parameters?
Code of Federal Regulations, 2011 CFR
2011-07-01
... diluent gas, document the relationship between oxygen and carbon dioxide, as specified in § 60.1255. (h... continuously monitored pollutants or parameters? 60.1365 Section 60.1365 Protection of Environment... Recordkeeping § 60.1365 What records must I keep for continuously monitored pollutants or parameters? You must...
40 CFR 60.1365 - What records must I keep for continuously monitored pollutants or parameters?
Code of Federal Regulations, 2013 CFR
2013-07-01
... diluent gas, document the relationship between oxygen and carbon dioxide, as specified in § 60.1255. (h... continuously monitored pollutants or parameters? 60.1365 Section 60.1365 Protection of Environment... Recordkeeping § 60.1365 What records must I keep for continuously monitored pollutants or parameters? You must...
40 CFR 60.1365 - What records must I keep for continuously monitored pollutants or parameters?
Code of Federal Regulations, 2012 CFR
2012-07-01
... diluent gas, document the relationship between oxygen and carbon dioxide, as specified in § 60.1255. (h... continuously monitored pollutants or parameters? 60.1365 Section 60.1365 Protection of Environment... Recordkeeping § 60.1365 What records must I keep for continuously monitored pollutants or parameters? You must...
40 CFR 60.1365 - What records must I keep for continuously monitored pollutants or parameters?
Code of Federal Regulations, 2014 CFR
2014-07-01
... diluent gas, document the relationship between oxygen and carbon dioxide, as specified in § 60.1255. (h... continuously monitored pollutants or parameters? 60.1365 Section 60.1365 Protection of Environment... Recordkeeping § 60.1365 What records must I keep for continuously monitored pollutants or parameters? You must...
Wheelchair propulsion kinematics in beginners and expert users: influence of wheelchair settings.
Gorce, P; Louis, N
2012-01-01
Biomechanical studies have linked the handrim wheelchair propulsion with a prevalence of upper limb musculoskeletal disorders. The purpose of this study was to examine the influence of the wheelchair settings on upper limb kinematics during wheelchair propulsion. Recordings were made under various wheelchair configuration conditions to understand the effect of wheelchair settings on kinematics parameters such shoulder, elbow and wrist angles. Ten experts and ten beginners' subjects propelled an experimental wheelchair on a roller ergometer system at a comfortable speed. Twelve wheelchair configurations were tested. Kinematics were recorded for each configuration. Based on the hand position relatively to the handrim, the main kinematic parameters of wheelchair propulsion were investigated on the whole propulsion cycle and a key event such as handrim contact and release. Compared to the beginner subjects, all the experts' subjects generally present higher joint amplitude and propulsion speeds. Seat height and antero-posterior axle position influence usage of the hand-rim, timing parameters and configurations of upper limb joints. Results seem to confirm that low and backward seat position allow a greater efficiency. Nevertheless, according that proximity of joint limit is a well known factor of musculoskeletal disorders, our results let us think that too low and backward seat position, increasing joints positions and amplitudes, could increase the risk of upper limb injuries in relation with manual wheelchair propulsion. Kinematic differences highlight that future studies on wheelchair propulsion should only be done with impaired experienced subjects. Furthermore, this study provides indications on how wheelchair settings can be used for upper limb injury prevention. Copyright © 2011 Elsevier Ltd. All rights reserved.
20 CFR 200.5 - Protection of privacy of records maintained on individuals.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 20 Employees' Benefits 1 2013-04-01 2012-04-01 true Protection of privacy of records maintained on individuals. 200.5 Section 200.5 Employees' Benefits RAILROAD RETIREMENT BOARD GENERAL ADMINISTRATION GENERAL ADMINISTRATION § 200.5 Protection of privacy of records maintained on individuals. (a) Purpose and scope. The purpose of this section is t...
20 CFR 200.5 - Protection of privacy of records maintained on individuals.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 20 Employees' Benefits 1 2011-04-01 2011-04-01 false Protection of privacy of records maintained on individuals. 200.5 Section 200.5 Employees' Benefits RAILROAD RETIREMENT BOARD GENERAL ADMINISTRATION GENERAL ADMINISTRATION § 200.5 Protection of privacy of records maintained on individuals. (a) Purpose and scope. The purpose of this section is...
20 CFR 200.5 - Protection of privacy of records maintained on individuals.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 20 Employees' Benefits 1 2014-04-01 2012-04-01 true Protection of privacy of records maintained on individuals. 200.5 Section 200.5 Employees' Benefits RAILROAD RETIREMENT BOARD GENERAL ADMINISTRATION GENERAL ADMINISTRATION § 200.5 Protection of privacy of records maintained on individuals. (a) Purpose and scope. The purpose of this section is t...
20 CFR 200.5 - Protection of privacy of records maintained on individuals.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 20 Employees' Benefits 1 2012-04-01 2012-04-01 false Protection of privacy of records maintained on individuals. 200.5 Section 200.5 Employees' Benefits RAILROAD RETIREMENT BOARD GENERAL ADMINISTRATION GENERAL ADMINISTRATION § 200.5 Protection of privacy of records maintained on individuals. (a) Purpose and scope. The purpose of this section is...
ERIC Educational Resources Information Center
Wiggley, Shirley L.
2011-01-01
Purpose: The purpose of this study was to examine the relationship between the electronic health record system components and patient outcomes in an acute hospital setting, given that the current presidential administration has earmarked nearly $50 billion to the implementation of the electronic health record. The relationship between the…
76 FR 4478 - Privacy Act of 1974; Report of Modified or Altered System of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-25
... contractors that have a need to know the information for the purpose of assisting the Department's efforts to... Records Narrative Statement I. Background and Purpose of the System A. Background The Department of Health... information for the purpose of assisting the Department's efforts to respond to a suspected or confirmed...
76 FR 4454 - Privacy Act of 1974; Report of Modified or Altered System of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-25
... Federal agencies and Department contractors that have a need to know the information for the purpose of.../NIOSH.'' The purpose of this system is to develop composite data summaries to support the development of... Records Narrative Statement I. Background and Purpose of the System A. Background The Department of Health...
76 FR 4445 - Privacy Act of 1974; Report of Modified or Altered System of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-25
... federal agencies and Department contractors that have a need to know the information for the purpose of... of Records Narrative Statement I. Background and Purpose of the System A. Background The Department... and Department contractors that have a need to know the information for the purpose of assisting the...
76 FR 4438 - Privacy Act of 1974; Report of Modified or Altered System of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-25
... information for the purpose of assisting the Department's efforts to respond to a suspected or confirmed... Altered System of Records Narrative Statement I. Background and Purpose of the System A. Background The... for the purpose of assisting the Department's efforts to respond to a suspected or confirmed breach of...
76 FR 4440 - Privacy Act of 1974; Report of Modified or Altered System of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-25
... that have a need to know the information for the purpose of assisting the Department's efforts to... Mycobacterioses--Report of Modified or Altered System of Records Narrative Statement I. Background and Purpose of... that have a need to know the information for the purpose of assisting the Department's efforts to...
18 CFR 1301.11 - Purpose and scope.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 18 Conservation of Power and Water Resources 2 2011-04-01 2011-04-01 false Purpose and scope. 1301... Privacy Act § 1301.11 Purpose and scope. (a) The regulations in §§ 1301.11 to 1301.24 implement section 3... existence of the record, when TVA receives requests related to these records, TVA will immediately refer the...
18 CFR 1301.11 - Purpose and scope.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 18 Conservation of Power and Water Resources 2 2010-04-01 2010-04-01 false Purpose and scope. 1301... Privacy Act § 1301.11 Purpose and scope. (a) The regulations in §§ 1301.11 to 1301.24 implement section 3... existence of the record, when TVA receives requests related to these records, TVA will immediately refer the...
Eissa, Iman M; Khalil, Noha M; El-Gendy, Heba A
2016-01-01
Purpose. To assess the tear film quantity and correlate it with the quality and stability of the tear film in diabetics and compare them to age matched controls. Introduction. Diabetes affects tear film parameters in multiple ways. Poor metabolic control and neuropathy are postulated factors. To further understand how diabetes affects tear film parameters this study was conducted. Subjects and Methods. Tear meniscus height was measured by anterior segment OCT, along with tear thinning time, a subtype of noninvasive tear break-up time, and blinking rate per minute which were all recorded for 22 diabetic patients. Correlations between these tear film parameters were studied and then compared to 16 age matched controls. Results. A statistically significant difference was found in blinking rate between the diabetic and the control group (P = 0.002), with higher blinking rate among diabetics. All tear film parameters were negatively correlated with duration of diabetes. A positive correlation was found between tear film volume and stability. Conclusion. Diabetes affects the tear film in various ways. Diabetics should be examined for dry eye signs even in absence of symptoms which may be masked by associated neuropathy. Duration of diabetes has an impact on tear film status.
NASA Astrophysics Data System (ADS)
Vaithiyanathan, Thanapal; Sundaramoorthy, Perumal
2017-12-01
Sugar industry is a very important agro-based industry in India and it discharges large amount of effluent into water bodies to create high pollution in water bodies which affects the plants and other living organisms. In the present investigation, the physico-chemical analyses of N. P. K. R. Ramaswamy co-operative sugar mill effluent was determined and impact of different concentrations (control, 10, 25, 50, 75 and 100%) of sugar mill effluent on seed germination behavior of African marigold ( Tagetes erecta L.) was studied. The morphological parameters such as germination percentage, shoot length, root length, fresh weight and dry weight of seedlings, seed vigour index, tolerance index and percentage of phytotoxicity were calculated. The results recorded for the analyses of sugar mill effluent indicated their some parameters such as PH, EC, acidity, TDS, TS, BOD, COD, sulphate, magnesium, nitrogen, zinc, iron, copper, lead, manganese and oil and grease exceeded the permissible limit compared to Tamil Nadu Pollution Control Board (TNPCB) and then germination and growth parameters increased in lower (10%) concentration of sugar mill effluent and this morphological parameters gradually decreased with increasing effluent concentration. The lower (10%) concentration of sugar mill effluent may be used for irrigation purposes.
Kondo, Takashi; Muneta, Takeshi; Fukui, Tsutomu
2017-03-01
[Purpose] To investigate the relationship between the static measurement of the transverse arch of the forefoot, using a 3-dimensional (3D) foot scanner, and kinetics and kinematics of gait parameters in the sagittal plane. [Subjects and Methods] Twenty healthy subjects participated in this study. The transverse arch of the forefoot was measured under three conditions as follows: condition 1, sitting; condition 2, standing; and condition 3, foot forward and lower leg tilting anteriorly to the maximum position with heel contact. Gait parameters were recorded using a 3D motion analysis system and force plate. Correlation coefficients between TAF for each comparison of conditions and gait parameters were calculated using the Spearman correlation analysis. [Results] Rates of the transverse arch of the forefoot width and height between condition 2 and condition 3 were significantly correlated with the anterior and posterior component of ground reaction forces, the hip joint extension angle, and the ankle plantar flexion moment. [Conclusion] Our study's findings indicated that increased stiffness of the transverse arch of the forefoot was related to the increase in ankle plantar moment, and decreased stiffness of the transverse arch of the forefoot was related to the increase in hip joint extension angle during gait.
Kondo, Takashi; Muneta, Takeshi; Fukui, Tsutomu
2017-01-01
[Purpose] To investigate the relationship between the static measurement of the transverse arch of the forefoot, using a 3-dimensional (3D) foot scanner, and kinetics and kinematics of gait parameters in the sagittal plane. [Subjects and Methods] Twenty healthy subjects participated in this study. The transverse arch of the forefoot was measured under three conditions as follows: condition 1, sitting; condition 2, standing; and condition 3, foot forward and lower leg tilting anteriorly to the maximum position with heel contact. Gait parameters were recorded using a 3D motion analysis system and force plate. Correlation coefficients between TAF for each comparison of conditions and gait parameters were calculated using the Spearman correlation analysis. [Results] Rates of the transverse arch of the forefoot width and height between condition 2 and condition 3 were significantly correlated with the anterior and posterior component of ground reaction forces, the hip joint extension angle, and the ankle plantar flexion moment. [Conclusion] Our study’s findings indicated that increased stiffness of the transverse arch of the forefoot was related to the increase in ankle plantar moment, and decreased stiffness of the transverse arch of the forefoot was related to the increase in hip joint extension angle during gait. PMID:28356622
Prasad, Nikhil K; Coleman Wood, Krista A; Spinner, Robert J; Kaufman, Kenton R
The assessment of neuromuscular recovery after peripheral nerve surgery has typically been a subjective physical examination. The purpose of this report was to assess the value of gait analysis in documenting recovery quantitatively. A professional football player underwent gait analysis before and after surgery for a peroneal intraneural ganglion cyst causing a left-sided foot drop. Surface electromyography (SEMG) recording from surface electrodes and motion parameter acquisition from a computerized motion capture system consisting of 10 infrared cameras were performed simultaneously. A comparison between SEMG recordings before and after surgery showed a progression from disorganized activation in the left tibialis anterior and peroneus longus muscles to temporally appropriate activation for the phase of the gait cycle. Kinematic analysis of ankle motion planes showed resolution from a complete foot drop preoperatively to phase-appropriate dorsiflexion postoperatively. Gait analysis with dynamic SEMG and motion capture complements physical examination when assessing postoperative recovery in athletes.
NASA Technical Reports Server (NTRS)
Biezad, D. J.; Schmidt, D. K.; Leban, F.; Mashiko, S.
1986-01-01
Single-channel pilot manual control output in closed-tracking tasks is modeled in terms of linear discrete transfer functions which are parsimonious and guaranteed stable. The transfer functions are found by applying a modified super-position time series generation technique. A Levinson-Durbin algorithm is used to determine the filter which prewhitens the input and a projective (least squares) fit of pulse response estimates is used to guarantee identified model stability. Results from two case studies are compared to previous findings, where the source of data are relatively short data records, approximately 25 seconds long. Time delay effects and pilot seasonalities are discussed and analyzed. It is concluded that single-channel time series controller modeling is feasible on short records, and that it is important for the analyst to determine a criterion for best time domain fit which allows association of model parameter values, such as pure time delay, with actual physical and physiological constraints. The purpose of the modeling is thus paramount.
NASA Technical Reports Server (NTRS)
Pace, N.; Rahlmann, D. F.; Mains, R. C.; Kodama, A. M.; Mccutcheon, E. P.
1978-01-01
An adult male pig-tailed monkey (Macaca nemestrina) with surgically implanted biotelemetry unit was inserted into a fiberglass pod system which was installed in a Spacelab mock-up to simulate a 6-day mission during which extensive physiological measurements were obtained. The purpose of the pod was to make possible the study of respiratory gas exchange. Body temperature and selected cardiovascular parameters were recorded continuously for 2.6 days prior to 'launch', 6.3 days during 'flight', and 1.8 days after 'landing'. The results are surveyed, and it is concluded that it is feasible to perform sound physiological experiments on nonhuman primates in the Spacelab environment
An Automated Recording Method in Clinical Consultation to Rate the Limp in Lower Limb Osteoarthritis
Barrois, R.; Gregory, Th.; Oudre, L.; Moreau, Th.; Truong, Ch.; Aram Pulini, A.; Vienne, A.; Labourdette, Ch.; Vayatis, N.; Buffat, S.; Yelnik, A.; de Waele, C.; Laporte, S.; Vidal, P. P.; Ricard, D.
2016-01-01
For diagnosis and follow up, it is important to be able to quantify limp in an objective, and precise way adapted to daily clinical consultation. The purpose of this exploratory study was to determine if an inertial sensor-based method could provide simple features that correlate with the severity of lower limb osteoarthritis evaluated by the WOMAC index without the use of step detection in the signal processing. Forty-eight patients with lower limb osteoarthritis formed two severity groups separated by the median of the WOMAC index (G1, G2). Twelve asymptomatic age-matched control subjects formed the control group (G0). Subjects were asked to walk straight 10 meters forward and 10 meters back at self-selected walking speeds with inertial measurement units (IMU) (3-D accelerometers, 3-D gyroscopes and 3-D magnetometers) attached on the head, the lower back (L3-L4) and both feet. Sixty parameters corresponding to the mean and the root mean square (RMS) of the recorded signals on the various sensors (head, lower back and feet), in the various axes, in the various frames were computed. Parameters were defined as discriminating when they showed statistical differences between the three groups. In total, four parameters were found discriminating: mean and RMS of the norm of the acceleration in the horizontal plane for contralateral and ipsilateral foot in the doctor’s office frame. No discriminating parameter was found on the head or the lower back. No discriminating parameter was found in the sensor linked frames. This study showed that two IMUs placed on both feet and a step detection free signal processing method could be an objective and quantitative complement to the clinical examination of the physician in everyday practice. Our method provides new automatically computed parameters that could be used for the comprehension of lower limb osteoarthritis. It may not only be used in medical consultation to score patients but also to monitor the evolution of their clinical syndrome during and after rehabilitation. Finally, it paves the way for the quantification of gait in other fields such as neurology and for monitoring the gait at a patient’s home. PMID:27776168
NASA Astrophysics Data System (ADS)
Karimzadeh, Shaghayegh; Askan, Aysegul; Yakut, Ahmet
2017-09-01
Simulated ground motions can be used in structural and earthquake engineering practice as an alternative to or to augment the real ground motion data sets. Common engineering applications of simulated motions are linear and nonlinear time history analyses of building structures, where full acceleration records are necessary. Before using simulated ground motions in such applications, it is important to assess those in terms of their frequency and amplitude content as well as their match with the corresponding real records. In this study, a framework is outlined for assessment of simulated ground motions in terms of their use in structural engineering. Misfit criteria are determined for both ground motion parameters and structural response by comparing the simulated values against the corresponding real values. For this purpose, as a case study, the 12 November 1999 Duzce earthquake is simulated using stochastic finite-fault methodology. Simulated records are employed for time history analyses of frame models of typical residential buildings. Next, the relationships between ground motion misfits and structural response misfits are studied. Results show that the seismological misfits around the fundamental period of selected buildings determine the accuracy of the simulated responses in terms of their agreement with the observed responses.
NASA Astrophysics Data System (ADS)
Mavroidis, Panayiotis; Lind, Bengt K.; Theodorou, Kyriaki; Laurell, Göran; Fernberg, Jan-Olof; Lefkopoulos, Dimitrios; Kappas, Constantin; Brahme, Anders
2004-08-01
The purpose of this work is to provide some statistical methods for evaluating the predictive strength of radiobiological models and the validity of dose-response parameters for tumour control and normal tissue complications. This is accomplished by associating the expected complication rates, which are calculated using different models, with the clinical follow-up records. These methods are applied to 77 patients who received radiation treatment for head and neck cancer and 85 patients who were treated for arteriovenous malformation (AVM). The three-dimensional dose distribution delivered to esophagus and AVM nidus and the clinical follow-up results were available for each patient. Dose-response parameters derived by a maximum likelihood fitting were used as a reference to evaluate their compatibility with the examined treatment methodologies. The impact of the parameter uncertainties on the dose-response curves is demonstrated. The clinical utilization of the radiobiological parameters is illustrated. The radiobiological models (relative seriality and linear Poisson) and the reference parameters are validated to prove their suitability in reproducing the treatment outcome pattern of the patient material studied (through the probability of finding a worse fit, area under the ROC curve and khgr2 test). The analysis was carried out for the upper 5 cm of the esophagus (proximal esophagus) where all the strictures are formed, and the total volume of AVM. The estimated confidence intervals of the dose-response curves appear to have a significant supporting role on their clinical implementation and use.
Code of Federal Regulations, 2011 CFR
2011-07-01
... wish to film, photograph, or videotape for news purposes at a Presidential library or at a regional records services facility, you must contact the director of the library (see 36 CFR 1253.3 for contact... 1254 for permission to film archival records and donated materials for research purposes or for...
Code of Federal Regulations, 2014 CFR
2014-07-01
... wish to film, photograph, or videotape for news purposes at a Presidential library or at a regional records services facility, you must contact the director of the library (see 36 CFR 1253.3 for contact... 1254 for permission to film archival records and donated materials for research purposes or for...
Code of Federal Regulations, 2012 CFR
2012-07-01
... wish to film, photograph, or videotape for news purposes at a Presidential library or at a regional records services facility, you must contact the director of the library (see 36 CFR 1253.3 for contact... 1254 for permission to film archival records and donated materials for research purposes or for...
5 CFR 293.101 - Purpose and scope.
Code of Federal Regulations, 2010 CFR
2010-01-01
....101 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS PERSONNEL RECORDS Basic Policies on Maintenance of Personnel Records § 293.101 Purpose and scope. (a) This subpart sets forth basic policies governing the creation, development, maintenance, processing, use...
NASA Astrophysics Data System (ADS)
Ji, Kun; Bouaanani, Najib; Wen, Ruizhi; Ren, Yefei
2018-05-01
This paper aims at implementing and introducing the use of conditional mean spectrum (CMS) and conditional spectrum (CS) as the main input parameters in the practice of seismic safety evaluation (SSE) in China, instead of the currently used uniform hazard spectrum (UHS). For this purpose, a procedure for M-R-epsilon seismic hazard deaggregation in China was first developed. For illustration purposes, two different typical sites in China, with one to two dominant seismic zones, were considered as examples to carry out seismic hazard deaggregation and illustrate the construction of CMS/CS. Two types of correlation coefficients were used to generate CMS and the results were compared over a vibration period range of interest. Ground motion records were selected from the NSMONS (2007-2015) and PEER NGA-West2 databases to correspond to the target CMS and CS. Hazard consistency of the spectral accelerations of the selected ground motion records was evaluated and validated by computing the annual exceedance probability rate of the response spectra and comparing the results to the hazard curve corresponding to each site of concern at different periods. The tools developed in this work and their illustrative application to specific case studies in China are a first step towards the adoption of CMS and CS into the practice of seismic safety evaluation in this country.
The fractal-multifractal method and temporal resolution: Application to precipitation and streamflow
NASA Astrophysics Data System (ADS)
Maskey, M.; Puente, C. E.; Sivakumar, B.
2017-12-01
In the past, we have established that the deterministic fractal-multifractal (FM) method is a promising geometric tool to analyze hydro-climatic variables, such as precipitation, river flow, and temperature. In this study, we address the issue of temporal resolution to advance the suitability and usefulness of the FM approach in hydro-climate. Specifically, we elucidate the evolution of FM geometric parameters as computed at different time scales ranging from a day to a month (30-day) in increments of a day. For this purpose, both rainfall and river discharge records at Sacramento, California gathered over a year are encoded at different time scales. The analysis reveals that: (a) the FM approach yields faithful encodings of both kinds of data sets at the resolutions considered with reasonably small errors; and (b) the "best" FM parameters ultimately converge when the resolution is increased, thus allowing visualizing both hydrologic attributes. By addressing the scalability of the geometric patterns, these results further advance the suitability of the FM approach.
Monitoring and evaluation of the water quality of Budeasa Reservoir-Arges River, Romania.
Ion, Antoanela; Vladescu, Luminita; Badea, Irinel Adriana; Comanescu, Laura
2016-09-01
The purpose of this study was to monitor and record the specific characteristics and properties of the Arges River water in the Budeasa Reservoir (the principal water resources of municipal tap water of the big Romanian city Pitesti and surrounding area) for a period of 5 years (2005-2009). The monitored physical and chemical parameters were turbidity, pH, electrical conductivity, chemical oxygen demand, 5 days biochemical oxygen demand, free dissolved oxygen, nitrite, nitrate, ammonia nitrogen, chloride, total dissolved iron ions, sulfate, manganese, phosphate, total alkalinity, and total hardness. The results were discussed in correlation with the precipitation values during the study. Monthly and annual values of each parameter determined in the period January 2005-December 2009 were used as a basis for the classification of Budeasa Reservoir water, according to the European legislation, as well as for assessing its quality as a drinking water supply. Principal component analysis and Pearson correlation coefficients were used as statistical procedures in order to evaluate the data obtained during this study.
Savitha, D; Sejil, T V; Rao, Shwetha; Roshan, C J; Roshan, C J
2013-01-01
The purpose of the study was to investigate the effect of vocal and instrumental music on various physiological parameters during submaximal exercise. Each subject underwent three sessions of exercise protocol without music, with vocal music, and instrumental versions of same piece of music. The protocol consisted of 10 min treadmill exercise at 70% HR(max) and 20 min of recovery. Minute to minute heart rate and breath by breath recording of respiratory parameters, rate of energy expenditure and perceived exertion levels were measured. Music, irrespective of the presence or absence of lyrics, enabled the subjects to exercise at a significantly lower heart rate and oxygen consumption, reduced the metabolic cost and perceived exertion levels of exercise (P < 0.05). There was faster recovery of systolic and diastolic blood pressures and exertion levels during the post exercise period. Music having a relaxant effect could have probably increased the parasympathetic activation leading to these effects.
EMG parameters and EEG α Index change at fatigue period during different types of muscle contraction
NASA Astrophysics Data System (ADS)
Zhang, Li; Zhou, Bin; Song, Gaoqing
2010-10-01
The purpose of this study is to measure and analyze the characteristics in change of EMG and EEG parameters at muscle fatigue period in participants with different exercise capacity. Twenty participants took part in the tests. They were divided into two groups, Group A (constant exerciser) and Group B (seldom-exerciser). MVC dynamic and 1/3 isometric exercises were performed; EMG and EEG signals were recorded synchronously during different type of muscle contraction. Results indicated that values of MVC, RMS and IEMG in Group A were greater than Group B, but isometric exercise time was shorter than the time of dynamic exercise although its intensity was light. Turning point of IEMG and α Index occurred synchronously during constant muscle contraction of isometric or dynamic exercise. It is concluded that IEMG turning point may be an indication to justify muscle fatigue. Synchronization of EEG and EMG reflects its common characteristics on its bio-electric change.
EMG parameters and EEG α Index change at fatigue period during different types of muscle contraction
NASA Astrophysics Data System (ADS)
Zhang, Li; Zhou, Bin; Song, Gaoqing
2011-03-01
The purpose of this study is to measure and analyze the characteristics in change of EMG and EEG parameters at muscle fatigue period in participants with different exercise capacity. Twenty participants took part in the tests. They were divided into two groups, Group A (constant exerciser) and Group B (seldom-exerciser). MVC dynamic and 1/3 isometric exercises were performed; EMG and EEG signals were recorded synchronously during different type of muscle contraction. Results indicated that values of MVC, RMS and IEMG in Group A were greater than Group B, but isometric exercise time was shorter than the time of dynamic exercise although its intensity was light. Turning point of IEMG and α Index occurred synchronously during constant muscle contraction of isometric or dynamic exercise. It is concluded that IEMG turning point may be an indication to justify muscle fatigue. Synchronization of EEG and EMG reflects its common characteristics on its bio-electric change.
Kent, A R; Grill, W M
2012-01-01
Deep brain stimulation (DBS) is an effective treatment for movement disorders, but the selection of stimulus parameters is a clinical burden and often yields sub-optimal outcomes for patients. Measurement of electrically evoked compound action potentials (ECAPs) during DBS could offer insight into the type and spatial extent of neural element activation and provide a potential feedback signal for the rational selection of stimulus parameters and closed-loop DBS. However, recording ECAPs presents a significant technical challenge due to the large stimulus artefact, which can saturate recording amplifiers and distort short latency ECAP signals. We developed DBS-ECAP recording instrumentation combining commercial amplifiers and circuit elements in a serial configuration to reduce the stimulus artefact and enable high fidelity recording. We used an electrical circuit equivalent model of the instrumentation to understand better the sources of the stimulus artefact and the mechanisms of artefact reduction by the circuit elements. In vitro testing validated the capability of the instrumentation to suppress the stimulus artefact and increase gain by a factor of 1,000 to 5,000 compared to a conventional biopotential amplifier. The distortion of mock ECAP (mECAP) signals was measured across stimulation parameters, and the instrumentation enabled high fidelity recording of mECAPs with latencies of only 0.5 ms for DBS pulse widths of 50 to 100 μs/phase. Subsequently, the instrumentation was used to record in vivo ECAPs, without contamination by the stimulus artefact, during thalamic DBS in an anesthetized cat. The characteristics of the physiological ECAP were dependent on stimulation parameters. The novel instrumentation enables high fidelity ECAP recording and advances the potential use of the ECAP as a feedback signal for the tuning of DBS parameters. PMID:22510375
Phonatory vocal tract stability in stuttering children before and after fluency--enhancing therapy.
Dehqan, A; Ali Dashti, G; Mirzadeh, M
2010-01-01
Stuttering is a complex disorder. Essentially, it is a neuromuscular disorder whose core consists of tiny lags and disruptions in the timing of the complicated movements required for speech. The purpose of the current study was to collec and comparg jitters and shimmer values in children who stutter before and after fluency--enhancing therapy. Subjects consisted of 15 Iranian preschool girls with stutterg, and 15 Iranial preschool girls without afflictions, matched according to age. Vocal jittering and shimmer measurements of thesphonation of the children were compared before and after therapy. Each subject phonated vowels nine times in a random order. Each phonation was sustained for at least five seconds and was recorded. The middle three-second portion of each recorded vowel phonation was subjected to jitter and shimmer analysis. On shimmer measures between pre-treatment and post treatment, significant differences were found in all sustained vowels of persons who stutter group and means of shimmer in post therapy were significantly lower than pre-treatment. Differences in jitter measurements were not significant between pre-treatment and post-treatment statuses and this parameter did not change after therapy. The findings showed that therapy resulted in decreaseg irregularity in the amplitude of vibrations (shimmer). In other words, the therapy increases the steady-state of the laryngeal system. Moreover, this parameter may be used as an index for the effectiveness of therapy.
NASA Astrophysics Data System (ADS)
Chowdhary, Girish; Mühlegg, Maximilian; Johnson, Eric
2014-08-01
In model reference adaptive control (MRAC) the modelling uncertainty is often assumed to be parameterised with time-invariant unknown ideal parameters. The convergence of parameters of the adaptive element to these ideal parameters is beneficial, as it guarantees exponential stability, and makes an online learned model of the system available. Most MRAC methods, however, require persistent excitation of the states to guarantee that the adaptive parameters converge to the ideal values. Enforcing PE may be resource intensive and often infeasible in practice. This paper presents theoretical analysis and illustrative examples of an adaptive control method that leverages the increasing ability to record and process data online by using specifically selected and online recorded data concurrently with instantaneous data for adaptation. It is shown that when the system uncertainty can be modelled as a combination of known nonlinear bases, simultaneous exponential tracking and parameter error convergence can be guaranteed if the system states are exciting over finite intervals such that rich data can be recorded online; PE is not required. Furthermore, the rate of convergence is directly proportional to the minimum singular value of the matrix containing online recorded data. Consequently, an online algorithm to record and forget data is presented and its effects on the resulting switched closed-loop dynamics are analysed. It is also shown that when radial basis function neural networks (NNs) are used as adaptive elements, the method guarantees exponential convergence of the NN parameters to a compact neighbourhood of their ideal values without requiring PE. Flight test results on a fixed-wing unmanned aerial vehicle demonstrate the effectiveness of the method.
Tape tracking and handling for magnetic tape recorders. [aboard spacecraft
NASA Technical Reports Server (NTRS)
Paroby, W.; Disilvestre, R.
1975-01-01
One of the critical performance and life limiting elements of a spacecraft tape recorder instrumentation system which has received little attention in technical literature is magnetic tape tracking and handling technology. This technology is required to understand how to gently transfer tape from one reel to another with proper alignment and a desirable uniform velocity at the read and write transducer heads. The increased demand for high data rate (i.e., multi-track spacecraft recording instrumentation systems), coupled with performance under extreme environmental conditions, requires a thorough knowledge of the various parameters which establish an optimum designed tape tracking and handling system. Stress analysis techniques are required to evaluate these parameters substantiated with test tape tracking data, to show the effect of each parameter on a tape recorder instrumentation tracking system. The technology is applicable to ground type tape recorders where the detrimental effects of edge guidance can be eliminated.
Single-Station Sigma for the Iranian Strong Motion Stations
NASA Astrophysics Data System (ADS)
Zafarani, H.; Soghrat, M. R.
2017-11-01
In development of ground motion prediction equations (GMPEs), the residuals are assumed to have a log-normal distribution with a zero mean and a standard deviation, designated as sigma. Sigma has significant effect on evaluation of seismic hazard for designing important infrastructures such as nuclear power plants and dams. Both aleatory and epistemic uncertainties are involved in the sigma parameter. However, ground-motion observations over long time periods are not available at specific sites and the GMPEs have been derived using observed data from multiple sites for a small number of well-recorded earthquakes. Therefore, sigma is dominantly related to the statistics of the spatial variability of ground motion instead of temporal variability at a single point (ergodic assumption). The main purpose of this study is to reduce the variability of the residuals so as to handle it as epistemic uncertainty. In this regard, it is tried to partially apply the non-ergodic assumption by removing repeatable site effects from total variability of six GMPEs driven from the local, Europe-Middle East and worldwide data. For this purpose, we used 1837 acceleration time histories from 374 shallow earthquakes with moment magnitudes ranging from M w 4.0 to 7.3 recorded at 370 stations with at least two recordings per station. According to estimated single-station sigma for the Iranian strong motion stations, the ratio of event-corrected single-station standard deviation ( Φ ss) to within-event standard deviation ( Φ) is about 0.75. In other words, removing the ergodic assumption on site response resulted in 25% reduction of the within-event standard deviation that reduced the total standard deviation by about 15%.
Prioritized Contact Transport Stream
NASA Technical Reports Server (NTRS)
Hunt, Walter Lee, Jr. (Inventor)
2015-01-01
A detection process, contact recognition process, classification process, and identification process are applied to raw sensor data to produce an identified contact record set containing one or more identified contact records. A prioritization process is applied to the identified contact record set to assign a contact priority to each contact record in the identified contact record set. Data are removed from the contact records in the identified contact record set based on the contact priorities assigned to those contact records. A first contact stream is produced from the resulting contact records. The first contact stream is streamed in a contact transport stream. The contact transport stream may include and stream additional contact streams. The contact transport stream may be varied dynamically over time based on parameters such as available bandwidth, contact priority, presence/absence of contacts, system state, and configuration parameters.
Methods of Muscle Activation Onset Timing Recorded During Spinal Manipulation.
Currie, Stuart J; Myers, Casey A; Krishnamurthy, Ashok; Enebo, Brian A; Davidson, Bradley S
2016-05-01
The purpose of this study was to determine electromyographic threshold parameters that most reliably characterize the muscular response to spinal manipulation and compare 2 methods that detect muscle activity onset delay: the double-threshold method and cross-correlation method. Surface and indwelling electromyography were recorded during lumbar side-lying manipulations in 17 asymptomatic participants. Muscle activity onset delays in relation to the thrusting force were compared across methods and muscles using a generalized linear model. The threshold combinations that resulted in the lowest Detection Failures were the "8 SD-0 milliseconds" threshold (Detection Failures = 8) and the "8 SD-10 milliseconds" threshold (Detection Failures = 9). The average muscle activity onset delay for the double-threshold method across all participants was 149 ± 152 milliseconds for the multifidus and 252 ± 204 milliseconds for the erector spinae. The average onset delay for the cross-correlation method was 26 ± 101 for the multifidus and 67 ± 116 for the erector spinae. There were no statistical interactions, and a main effect of method demonstrated that the delays were higher when using the double-threshold method compared with cross-correlation. The threshold parameters that best characterized activity onset delays were an 8-SD amplitude and a 10-millisecond duration threshold. The double-threshold method correlated well with visual supervision of muscle activity. The cross-correlation method provides several advantages in signal processing; however, supervision was required for some results, negating this advantage. These results help standardize methods when recording neuromuscular responses of spinal manipulation and improve comparisons within and across investigations. Copyright © 2016 National University of Health Sciences. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Carniel, Roberto; Di Cecca, Mauro; Jaquet, Olivier
2006-05-01
In the framework of the EU-funded project "Multi-disciplinary monitoring, modelling and forecasting of volcanic hazard" (MULTIMO), multiparametric data have been recorded at the MULTIMO station in Montserrat. Moreover, several other long time series, recorded at Montserrat and at other volcanoes, have been acquired in order to test stochastic and deterministic methodologies under development. Creating a general framework to handle data efficiently is a considerable task even for homogeneous data. In the case of heterogeneous data, this becomes a major issue. A need for a consistent way of browsing such a heterogeneous dataset in a user-friendly way therefore arose. Additionally, a framework for applying the calculation of the developed dynamical parameters on the data series was also needed in order to easily keep these parameters under control, e.g. for monitoring, research or forecasting purposes. The solution which we present is completely based on Open Source software, including Linux operating system, MySql database management system, Apache web server, Zope application server, Scilab math engine, Plone content management framework, Unified Modelling Language. From the user point of view the main advantage is the possibility of browsing through datasets recorded on different volcanoes, with different instruments, with different sampling frequencies, stored in different formats, all via a consistent, user- friendly interface that transparently runs queries to the database, gets the data from the main storage units, generates the graphs and produces dynamically generated web pages to interact with the user. The involvement of third parties for continuing the development in the Open Source philosophy and/or extending the application fields is now sought.
NASA Astrophysics Data System (ADS)
Ricciuto, Daniel M.; King, Anthony W.; Dragoni, D.; Post, Wilfred M.
2011-03-01
Many parameters in terrestrial biogeochemical models are inherently uncertain, leading to uncertainty in predictions of key carbon cycle variables. At observation sites, this uncertainty can be quantified by applying model-data fusion techniques to estimate model parameters using eddy covariance observations and associated biometric data sets as constraints. Uncertainty is reduced as data records become longer and different types of observations are added. We estimate parametric and associated predictive uncertainty at the Morgan Monroe State Forest in Indiana, USA. Parameters in the Local Terrestrial Ecosystem Carbon (LoTEC) are estimated using both synthetic and actual constraints. These model parameters and uncertainties are then used to make predictions of carbon flux for up to 20 years. We find a strong dependence of both parametric and prediction uncertainty on the length of the data record used in the model-data fusion. In this model framework, this dependence is strongly reduced as the data record length increases beyond 5 years. If synthetic initial biomass pool constraints with realistic uncertainties are included in the model-data fusion, prediction uncertainty is reduced by more than 25% when constraining flux records are less than 3 years. If synthetic annual aboveground woody biomass increment constraints are also included, uncertainty is similarly reduced by an additional 25%. When actual observed eddy covariance data are used as constraints, there is still a strong dependence of parameter and prediction uncertainty on data record length, but the results are harder to interpret because of the inability of LoTEC to reproduce observed interannual variations and the confounding effects of model structural error.
20 CFR 435.50 - Purpose of reports and records.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false Purpose of reports and records. 435.50 Section 435.50 Employees' Benefits SOCIAL SECURITY ADMINISTRATION UNIFORM ADMINISTRATIVE REQUIREMENTS FOR GRANTS AND AGREEMENTS WITH INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, OTHER NON-PROFIT ORGANIZATIONS...
22 CFR 505.1 - Purpose and scope.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Relations BROADCASTING BOARD OF GOVERNORS PRIVACY ACT REGULATION § 505.1 Purpose and scope. The Broadcasting Board of Governors (BBG) will protect individuals' privacy from misuses of their records, and grant individuals access to records concerning them which are maintained by the Agency's domestic and overseas...
Yuan, Hongwei; Poeggel, Sven; Newe, Thomas; Lewis, Elfed; Viphavakit, Charusluk; Leen, Gabriel
2017-03-10
A comprehensive study of the effect of a wide range of controlled human subject motion on Photoplethysmographic signals is reported. The investigation includes testing of two separate groups of 5 and 18 subjects who were asked to undertake set exercises whilst simultaneously monitoring a wide range of physiological parameters including Breathing Rate, Heart Rate and Localised Blood Pressure using commercial clinical sensing systems. The unique finger mounted PPG probe equipped with miniature three axis accelerometers for undertaking this investigation was a purpose built in-house version which is designed to facilitate reproducible application to a wide range of human subjects and the study of motion. The subjects were required to undertake several motion based exercises including standing, sitting and lying down and transitions between these states. They were also required to undertake set arm movements including arm-swinging and wrist rotation. A comprehensive set of experimental results corresponding to all motion inducing exercises have been recorded and analysed including the baseline (BL) value (DC component) and the amplitude of the oscillation of the PPG. All physiological parameters were also recorded as a simultaneous time varying waveform. The effects of the motion and specifically the localised Blood Pressure (BP) have been studied and related to possible influences of the Autonomic Nervous System (ANS) and hemodynamic pressure variations. It is envisaged that a comprehensive study of the effect of motion and the localised pressure fluctuations will provide valuable information for the future minimisation of motion artefact effect on the PPG signals of this probe and allow the accurate assessment of total haemoglobin concentration which is the primary function of the probe.
Brunner, Matthias; Romano, Vito; Steger, Bernhard; Vinciguerra, Riccardo; Lawman, Samuel; Williams, Bryan; Hicks, Nicholas; Czanner, Gabriela; Zheng, Yalin; Willoughby, Colin E; Kaye, Stephen B
2018-03-01
The purpose of this study was to compare optical coherence tomography angiography (OCTA) and indocyanine green angiography (ICGA) for the assessment of corneal neovascularization (CoNV). Patients with CoNV extending at least 3 mm into the cornea were included. All patients underwent corneal imaging at the same visit. Images were recorded using the AngioVue OCTA system (Optovue, Inc.) with the long corneal adaptor module (CAM-L). ICGA images were recorded with fluorescent filters using the Heidelberg system (HRA2 Scanning Laser Ophthalmoscope; Heidelberg Engineering). Images were graded for quality by two independent observers. Vessel parameters: area, number, diameter, branch and end points, and tortuosity, were compared between devices. Bland-Altman plots were used to assess differences between parameters. Fifteen patients with CoNV predominantly associated with microbial keratitis were included. Mean subjective image quality score was better for ICGA (3.3 ± 0.9) than for OCTA (2.1 ± 1.2, P = 0.002), with almost perfect interobserver agreement for ICGA images (κ = 0.83) and substantial agreement for OCTA images (κ = 0.69). Agreement of grading of all investigated vessel parameters between ICGA and OCT images was slight to moderate, with significant differences found for vessel diameter (-8.98 μm, P = 0.01, 95% limits of agreement [LOA]: -15.89 to -2.07), number of branch (25.93, P = 0.09, 95% LOA: -4.31 to 56.17), and terminal points (49, P = 0.05, 95% LOA: 0.78 to 97.22). Compared with ICGA, current OCTA systems are less precise in capturing small vessels in CoNV complexes, and validation studies are needed for OCTA segmentation software. OCTA, however, complements ICGA by providing evidence of red blood cell flow, which together with depth information, may be helpful when planning treatment of CoNV.
Differences between Outdoor and Indoor Sound Levels for Open, Tilted, and Closed Windows
Locher, Barbara; Piquerez, André; Habermacher, Manuel; Ragettli, Martina; Cajochen, Christian; Vienneau, Danielle; Foraster, Maria; Müller, Uwe; Wunderli, Jean Marc
2018-01-01
Noise exposure prediction models for health effect studies normally estimate free field exposure levels outside. However, to assess the noise exposure inside dwellings, an estimate of indoor sound levels is necessary. To date, little field data is available about the difference between indoor and outdoor noise levels and factors affecting the damping of outside noise. This is a major cause of uncertainty in indoor noise exposure prediction and may lead to exposure misclassification in health assessments. This study aims to determine sound level differences between the indoors and the outdoors for different window positions and how this sound damping is related to building characteristics. For this purpose, measurements were carried out at home in a sample of 102 Swiss residents exposed to road traffic noise. Sound pressure level recordings were performed outdoors and indoors, in the living room and in the bedroom. Three scenarios—of open, tilted, and closed windows—were recorded for three minutes each. For each situation, data on additional parameters such as the orientation towards the source, floor, and room, as well as sound insulation characteristics were collected. On that basis, linear regression models were established. The median outdoor–indoor sound level differences were of 10 dB(A) for open, 16 dB(A) for tilted, and 28 dB(A) for closed windows. For open and tilted windows, the most relevant parameters affecting the outdoor–indoor differences were the position of the window, the type and volume of the room, and the age of the building. For closed windows, the relevant parameters were the sound level outside, the material of the window frame, the existence of window gaskets, and the number of windows. PMID:29346318
Differences between Outdoor and Indoor Sound Levels for Open, Tilted, and Closed Windows.
Locher, Barbara; Piquerez, André; Habermacher, Manuel; Ragettli, Martina; Röösli, Martin; Brink, Mark; Cajochen, Christian; Vienneau, Danielle; Foraster, Maria; Müller, Uwe; Wunderli, Jean Marc
2018-01-18
Noise exposure prediction models for health effect studies normally estimate free field exposure levels outside. However, to assess the noise exposure inside dwellings, an estimate of indoor sound levels is necessary. To date, little field data is available about the difference between indoor and outdoor noise levels and factors affecting the damping of outside noise. This is a major cause of uncertainty in indoor noise exposure prediction and may lead to exposure misclassification in health assessments. This study aims to determine sound level differences between the indoors and the outdoors for different window positions and how this sound damping is related to building characteristics. For this purpose, measurements were carried out at home in a sample of 102 Swiss residents exposed to road traffic noise. Sound pressure level recordings were performed outdoors and indoors, in the living room and in the bedroom. Three scenarios-of open, tilted, and closed windows-were recorded for three minutes each. For each situation, data on additional parameters such as the orientation towards the source, floor, and room, as well as sound insulation characteristics were collected. On that basis, linear regression models were established. The median outdoor-indoor sound level differences were of 10 dB(A) for open, 16 dB(A) for tilted, and 28 dB(A) for closed windows. For open and tilted windows, the most relevant parameters affecting the outdoor-indoor differences were the position of the window, the type and volume of the room, and the age of the building. For closed windows, the relevant parameters were the sound level outside, the material of the window frame, the existence of window gaskets, and the number of windows.
36 CFR 1256.1 - What does this part cover?
Code of Federal Regulations, 2010 CFR
2010-07-01
... and to records in the physical custody of the Federal records centers. This part applies to records... Representatives, and Architect of the Capitol records except for the purpose of directing mandatory review...
2011-01-01
Background Electronic patient records are generally coded using extensive sets of codes but the significance of the utilisation of individual codes may be unclear. Item response theory (IRT) models are used to characterise the psychometric properties of items included in tests and questionnaires. This study asked whether the properties of medical codes in electronic patient records may be characterised through the application of item response theory models. Methods Data were provided by a cohort of 47,845 participants from 414 family practices in the UK General Practice Research Database (GPRD) with a first stroke between 1997 and 2006. Each eligible stroke code, out of a set of 202 OXMIS and Read codes, was coded as either recorded or not recorded for each participant. A two parameter IRT model was fitted using marginal maximum likelihood estimation. Estimated parameters from the model were considered to characterise each code with respect to the latent trait of stroke diagnosis. The location parameter is referred to as a calibration parameter, while the slope parameter is referred to as a discrimination parameter. Results There were 79,874 stroke code occurrences available for analysis. Utilisation of codes varied between family practices with intraclass correlation coefficients of up to 0.25 for the most frequently used codes. IRT analyses were restricted to 110 Read codes. Calibration and discrimination parameters were estimated for 77 (70%) codes that were endorsed for 1,942 stroke patients. Parameters were not estimated for the remaining more frequently used codes. Discrimination parameter values ranged from 0.67 to 2.78, while calibration parameters values ranged from 4.47 to 11.58. The two parameter model gave a better fit to the data than either the one- or three-parameter models. However, high chi-square values for about a fifth of the stroke codes were suggestive of poor item fit. Conclusion The application of item response theory models to coded electronic patient records might potentially contribute to identifying medical codes that offer poor discrimination or low calibration. This might indicate the need for improved coding sets or a requirement for improved clinical coding practice. However, in this study estimates were only obtained for a small proportion of participants and there was some evidence of poor model fit. There was also evidence of variation in the utilisation of codes between family practices raising the possibility that, in practice, properties of codes may vary for different coders. PMID:22176509
Code of Federal Regulations, 2010 CFR
2010-01-01
... Administrative Personnel MERIT SYSTEMS PROTECTION BOARD ORGANIZATION AND PROCEDURES AVAILABILITY OF OFFICIAL INFORMATION Purpose and Scope § 1204.2 Scope. (a) For the purpose of this part, the term record and any other term used in reference to information includes any information that would be a Board record subject to...
Code of Federal Regulations, 2012 CFR
2012-01-01
... Administrative Personnel MERIT SYSTEMS PROTECTION BOARD ORGANIZATION AND PROCEDURES AVAILABILITY OF OFFICIAL INFORMATION Purpose and Scope § 1204.2 Scope. (a) For the purpose of this part, the term record and any other term used in reference to information includes any information that would be a Board record subject to...
Code of Federal Regulations, 2013 CFR
2013-01-01
... Administrative Personnel MERIT SYSTEMS PROTECTION BOARD ORGANIZATION AND PROCEDURES AVAILABILITY OF OFFICIAL INFORMATION Purpose and Scope § 1204.2 Scope. (a) For the purpose of this part, the term record and any other term used in reference to information includes any information that would be a Board record subject to...
Code of Federal Regulations, 2011 CFR
2011-01-01
... Administrative Personnel MERIT SYSTEMS PROTECTION BOARD ORGANIZATION AND PROCEDURES AVAILABILITY OF OFFICIAL INFORMATION Purpose and Scope § 1204.2 Scope. (a) For the purpose of this part, the term record and any other term used in reference to information includes any information that would be a Board record subject to...
Code of Federal Regulations, 2014 CFR
2014-01-01
... Administrative Personnel MERIT SYSTEMS PROTECTION BOARD ORGANIZATION AND PROCEDURES AVAILABILITY OF OFFICIAL INFORMATION Purpose and Scope § 1204.2 Scope. (a) For the purpose of this part, the term record and any other term used in reference to information includes any information that would be a Board record subject to...
40 CFR 98.214 - Monitoring and QA/QC requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... (for Equation U-2 of this subpart) must be determined annually from monthly measurements using the same plant instruments used for accounting purposes including purchase records or direct measurement, such as... accounting purposes including purchase records or direct measurement, such as weigh hoppers or belt weigh...
40 CFR 98.334 - Monitoring and QA/QC requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... used for accounting purposes including direct measurement weighing or through the use of purchase records same plant instruments or procedures that are used for accounting purposes (such as weigh hoppers... density and volume measurements, etc.). Record the total mass for the materials consumed each calendar...
14 CFR 49.15 - Fees for recording.
Code of Federal Regulations, 2014 CFR
2014-01-01
... therein $5.00 (2) Conveyance, made for security purposes, of a specifically identified aircraft engine or propeller, or any assignment or amendment thereof, or supplement thereto, recorded under Subpart D— For each engine or propeller 5.00 (3) Conveyance, made for security purposes, of aircraft engines, propellers...
14 CFR 49.15 - Fees for recording.
Code of Federal Regulations, 2012 CFR
2012-01-01
... therein $5.00 (2) Conveyance, made for security purposes, of a specifically identified aircraft engine or propeller, or any assignment or amendment thereof, or supplement thereto, recorded under Subpart D— For each engine or propeller 5.00 (3) Conveyance, made for security purposes, of aircraft engines, propellers...
14 CFR 49.15 - Fees for recording.
Code of Federal Regulations, 2013 CFR
2013-01-01
... therein $5.00 (2) Conveyance, made for security purposes, of a specifically identified aircraft engine or propeller, or any assignment or amendment thereof, or supplement thereto, recorded under Subpart D— For each engine or propeller 5.00 (3) Conveyance, made for security purposes, of aircraft engines, propellers...
14 CFR 49.15 - Fees for recording.
Code of Federal Regulations, 2010 CFR
2010-01-01
... therein $5.00 (2) Conveyance, made for security purposes, of a specifically identified aircraft engine or propeller, or any assignment or amendment thereof, or supplement thereto, recorded under Subpart D— For each engine or propeller 5.00 (3) Conveyance, made for security purposes, of aircraft engines, propellers...
14 CFR 49.15 - Fees for recording.
Code of Federal Regulations, 2011 CFR
2011-01-01
... therein $5.00 (2) Conveyance, made for security purposes, of a specifically identified aircraft engine or propeller, or any assignment or amendment thereof, or supplement thereto, recorded under Subpart D— For each engine or propeller 5.00 (3) Conveyance, made for security purposes, of aircraft engines, propellers...
[Ethics guidelines for the creation and use of registries for biomedical research purposes].
Abajo Iglesias, Francisco J de; Feito Grande, Lydia; Júdez Gutiérrez, Javier; Martín Arribas, M Concepción; Terracini, Benedetto; Pàmpols Ros, Teresa; Campos Castelló, Jaime; Martín Uranga, Amelia; Abascal Alonso, Moisés; Herrera Carranza, Joaquín; Sánchez Martínez, María José
2008-01-01
The clinical information stored in registries and records of different types is a fundamental tool for biomedical research. Up until just a few years ago, hardly any limitations existed on the creation and use of epidemiological registries or the use of information from pre-existing records for research purposes. This situation has changed substantially due mainly to the growing importance current laws place upon the safeguarding of the privacy and confidentiality of personal data. Although the legal framework is already quite explicit, a certain degree of leeway exists for ethical debate and prudence advice for the purpose of conducting valid, useful research with this information which will also respect the rights of the subjects and the laws in force. These guidelines deal with those aspects which have been considered relevant from an ethical standpoint in the handling of records and registries for research-related purposes, including not only the use but also the creation proper of the registries. A total of twenty-four recommendations are provided, grouped into ten sections: warranting of the creation of registry, organization and definition of responsibilities, scientific validity of the research project, ethical requirements of the collections of anonymous and anonymized data, ethical requirements of the registries including personal data, uses of medical records for research purposes, use of historical records of deceased individuals, contact with the research subjects, notification of results and review by a Research Ethics Committee.
Comparison between uroflowmetry and sonouroflowmetry in recording of urinary flow in healthy men.
Krhut, Jan; Gärtner, Marcel; Sýkora, Radek; Hurtík, Petr; Burda, Michal; Luňáček, Libor; Zvarová, Katarína; Zvara, Peter
2015-08-01
To evaluate the accuracy of sonouroflowmetry in recording urinary flow parameters and voided volume. A total of 25 healthy male volunteers (age 18-63 years) were included in the study. All participants were asked to carry out uroflowmetry synchronous with recording of the sound generated by the urine stream hitting the water level in the urine collection receptacle, using a dedicated cell phone. From 188 recordings, 34 were excluded, because of voided volume <150 mL or technical problems during recording. Sonouroflowmetry recording was visualized in a form of a trace, representing sound intensity over time. Subsequently, the matching datasets of uroflowmetry and sonouroflowmetry were compared with respect to flow time, voided volume, maximum flow rate and average flow rate. Pearson's correlation coefficient was used to compare parameters recorded by uroflowmetry with those calculated based on sonouroflowmetry recordings. The flow pattern recorded by sonouroflowmetry showed a good correlation with the uroflowmetry trace. A strong correlation (Pearson's correlation coefficient 0.87) was documented between uroflowmetry-recorded flow time and duration of the sound signal recorded with sonouroflowmetry. A moderate correlation was observed in voided volume (Pearson's correlation coefficient 0.68) and average flow rate (Pearson's correlation coefficient 0.57). A weak correlation (Pearson's correlation coefficient 0.38) between maximum flow rate recorded using uroflowmetry and sonouroflowmetry-recorded peak sound intensity was documented. The present study shows that the basic concept utilizing sound analysis for estimation of urinary flow parameters and voided volume is valid. However, further development of this technology and standardization of recording algorithm are required. © 2015 The Japanese Urological Association.
Privacy Act System of Records: Libby Asbestos Exposure Assessment Records, EPA-48
Learn about the Libby Asbestos Exposure Assessment Records System, including who is covered in the system, the purpose of data collection, routine uses for the system's records, and other security procedure.
Privacy Act System of Records: EPA Telecommunications Detail Records, EPA-32
Learn more about the EPA Telecommunications Detail Records System, including who is covered in the system, the purpose of data collection, routine uses for the system's records, and other security procedures.
Signal Feature Analysis Using Neural Networks & Psychoacoustics
1993-05-01
large class file on the DAT recording . This processing produced signals which ranged in length from 13200 and 39650 points. The extractions produced ... recorded . This signal set, denoted as "Air" signals , lacked the parameter of angle but added the parameter of striker (metal, plastic, and wood...the subjects were recorded . These became r.4 w data for confusion matrices which described how often a subject confused the class of a signal
Lee, Wonseok; Bae, Hyoung Won; Lee, Si Hyung; Kim, Chan Yun
2017-01-01
Purpose To assess the accuracy of intraocular lens (IOL) power prediction for cataract surgery with open angle glaucoma (OAG) and to identify preoperative angle parameters correlated with postoperative unpredicted refractive errors. Materials and Methods This study comprised 45 eyes from 45 OAG subjects and 63 eyes from 63 non-glaucomatous cataract subjects (controls). We investigated differences in preoperative predicted refractive errors and postoperative refractive errors for each group. Preoperative predicted refractive errors were obtained by biometry (IOL-master) and compared to postoperative refractive errors measured by auto-refractometer 2 months postoperatively. Anterior angle parameters were determined using swept source optical coherence tomography. We investigated correlations between preoperative angle parameters [angle open distance (AOD); trabecular iris surface area (TISA); angle recess area (ARA); trabecular iris angle (TIA)] and postoperative unpredicted refractive errors. Results In patients with OAG, significant differences were noted between preoperative predicted and postoperative real refractive errors, with more myopia than predicted. No significant differences were recorded in controls. Angle parameters (AOD, ARA, TISA, and TIA) at the superior and inferior quadrant were significantly correlated with differences between predicted and postoperative refractive errors in OAG patients (-0.321 to -0.408, p<0.05). Superior quadrant AOD 500 was significantly correlated with postoperative refractive differences in multivariate linear regression analysis (β=-2.925, R2=0.404). Conclusion Clinically unpredicted refractive errors after cataract surgery were more common in OAG than in controls. Certain preoperative angle parameters, especially AOD 500 at the superior quadrant, were significantly correlated with these unpredicted errors. PMID:28120576
77 FR 28383 - Information Collection Being Reviewed by the Federal Communications Commission
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-14
..., Digital Selective Calling (DSC) Operating Procedures--Maritime Mobile Identity (MMSI). Form Number: N/A... Annual Cost: N/A. Privacy Impact Assessment: Yes. The Commission maintains a system of records notice (SORN), FCC/WTB-1, ``Wireless Services Licensing Records,'' that covers this collection, purpose(s...
75 FR 21264 - Privacy Act of 1974; System of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-23
... Defense. A0030-22 AMC System name: Army Food Management Information System Records System location.... 9397, as amended. Purpose(s): The Army Food Management Information System will be used to automate the...: Supervisor, Army Food Management Information System, Program Manager, 401 First Street, Suite 157, Fort Lee...
21 CFR 21.61 - Exempt systems.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 1 2013-04-01 2013-04-01 false Exempt systems. 21.61 Section 21.61 Food and Drugs... Exemptions § 21.61 Exempt systems. (a) Investigatory records compiled for law enforcement purposes, including criminal law enforcement purposes, in the Food and Drug Administration Privacy Act Record Systems listed in...
21 CFR 21.61 - Exempt systems.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 1 2012-04-01 2012-04-01 false Exempt systems. 21.61 Section 21.61 Food and Drugs... Exemptions § 21.61 Exempt systems. (a) Investigatory records compiled for law enforcement purposes, including criminal law enforcement purposes, in the Food and Drug Administration Privacy Act Record Systems listed in...
Physician Sensemaking and Readiness for Electronic Medical Records
ERIC Educational Resources Information Center
Riesenmy, Kelly Rouse
2010-01-01
Purpose: The purpose of this paper is to explore physician sensemaking and readiness to implement electronic medical records (EMR) as a first step to finding strategies that enhance EMR adoption behaviors. Design/methodology/approach: The case study approach provides a detailed analysis of individuals within an organizational unit. Using a…
32 CFR 1901.01 - Authority and purpose.
Code of Federal Regulations, 2011 CFR
2011-07-01
... National Defense Other Regulations Relating to National Defense CENTRAL INTELLIGENCE AGENCY PUBLIC RIGHTS... Intelligence Agency Act of 1949, as amended (50 U.S.C. 403g). (b) Purpose in general. This part prescribes... Intelligence Agency maintains a record concerning them in any non-exempt portion of a system of records or any...
32 CFR 1901.01 - Authority and purpose.
Code of Federal Regulations, 2013 CFR
2013-07-01
... National Defense Other Regulations Relating to National Defense CENTRAL INTELLIGENCE AGENCY PUBLIC RIGHTS... Intelligence Agency Act of 1949, as amended (50 U.S.C. 403g). (b) Purpose in general. This part prescribes... Intelligence Agency maintains a record concerning them in any non-exempt portion of a system of records or any...
27 CFR 40.183 - Record of tobacco products.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 27 Alcohol, Tobacco Products and Firearms 2 2012-04-01 2011-04-01 true Record of tobacco products...) Use of the United States, and (6) Experimental purposes off factory premises; (g) Otherwise disposed...) Use for experimental purposes on factory premises, (4) Loss, (5) Destruction, and (6) Reduction to...
49 CFR 802.1 - Purpose and scope.
Code of Federal Regulations, 2010 CFR
2010-10-01
... RULES IMPLEMENTING THE PRIVACY ACT OF 1974 Applicability and Policy § 802.1 Purpose and scope. The.... NTSB policy encompasses the safeguarding of individual privacy from any misuse of Federal records and the provision of access to individuals to NTSB records concerning them, except where such access is in...
45 CFR 74.50 - Purpose of reports and records.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 45 Public Welfare 1 2013-10-01 2013-10-01 false Purpose of reports and records. 74.50 Section 74.50 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL ADMINISTRATION UNIFORM ADMINISTRATIVE REQUIREMENTS FOR AWARDS AND SUBAWARDS TO INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, OTHER NONPROFIT ORGANIZATIONS, AND COMMERCIAL ORGANIZATIONS...
INTEGRATION OF AIRBORNE DATA RECORDERS AND GROUND-BASED COMPUTERS FOR ENGINE MAINTENANCE PURPOSES.
what is known as ASTROLOG . The other parts of the ASTROLOG include FAA crash recording capability on an extra channel of the existing voice recorder...and a continuously recording, magnetic tape, flight performance recorder. Highlights of the engine maintenance recorder portion of the ASTROLOG are discussed.
36 CFR 1600.3 - Requests for records.
Code of Federal Regulations, 2011 CFR
2011-07-01
... FOIA does not require the Foundation to: (1) Compile or create records solely for the purpose of satisfying a request for records; (2) Provide records not yet in existence, even if such records may be expected to come into existence at some future time; or (3) Restore records destroyed or otherwise disposed...
Messaraa, C; Metois, A; Walsh, M; Hurley, S; Doyle, L; Mansfield, A; O'Connor, C; Mavon, A
2018-01-24
Skin topographic measurements are of paramount importance in the field of dermo-cosmetic evaluation. The aim of this study was to investigate how the Antera 3D, a multi-purpose handheld camera, correlates with other topographic techniques and changes in skin topography following the use of a cosmetic product. Skin topographic measurements were collected on 26 female volunteers aged 45-70 years with the Antera 3D, the DermaTOP and image analysis on parallel-polarized pictures. Different filters for analysis from the Antera 3D were investigated for repeatability, correlations with other imaging techniques and ability to detect improvements of skin topography following application of a serum. Most of Antera 3D parameters were found to be strongly correlated with the DermaTOP parameters. No association was found between the Antera 3D parameters and measurements on parallel-polarized photographs. The measurements repeatability was comparable among the different filters for analysis, with the exception of wrinkle max depth and roughness Rt. Following a single application of a tightening serum, both Antera 3D wrinkles and texture parameters were able to record significant improvements, with the best improvements observed with the large filter. The Antera 3D demonstrated its relevance for cosmetic product evaluation. We also provide recommendations for the analysis based on our findings. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Kent, A R; Grill, W M
2012-06-01
The clinical efficacy of deep brain stimulation (DBS) for the treatment of movement disorders depends on the identification of appropriate stimulation parameters. Since the mechanisms of action of DBS remain unclear, programming sessions can be time consuming, costly and result in sub-optimal outcomes. Measurement of electrically evoked compound action potentials (ECAPs) during DBS, generated by activated neurons in the vicinity of the stimulating electrode, could offer insight into the type and spatial extent of neural element activation and provide a potential feedback signal for the rational selection of stimulation parameters and closed-loop DBS. However, recording ECAPs presents a significant technical challenge due to the large stimulus artefact, which can saturate recording amplifiers and distort short latency ECAP signals. We developed DBS-ECAP recording instrumentation combining commercial amplifiers and circuit elements in a serial configuration to reduce the stimulus artefact and enable high fidelity recording. We used an electrical circuit equivalent model of the instrumentation to understand better the sources of the stimulus artefact and the mechanisms of artefact reduction by the circuit elements. In vitro testing validated the capability of the instrumentation to suppress the stimulus artefact and increase gain by a factor of 1000 to 5000 compared to a conventional biopotential amplifier. The distortion of mock ECAP (mECAP) signals was measured across stimulation parameters, and the instrumentation enabled high fidelity recording of mECAPs with latencies of only 0.5 ms for DBS pulse widths of 50 to 100 µs/phase. Subsequently, the instrumentation was used to record in vivo ECAPs, without contamination by the stimulus artefact, during thalamic DBS in an anesthetized cat. The characteristics of the physiological ECAP were dependent on stimulation parameters. The novel instrumentation enables high fidelity ECAP recording and advances the potential use of the ECAP as a feedback signal for the tuning of DBS parameters.
Privacy Act System of Records: Employee Counseling and Assistance Program Records, EPA-27
Learn about the Employee Counseling and Assistance Program Records System, including who is covered in the system, the purpose of data collection, routine uses for the system's records, and other security procedures.
Evaluation of auto incident recording system (AIRS).
DOT National Transportation Integrated Search
2005-05-01
The Auto Incident Recording System (AIRS) is a sound-actuated video recording system. It automatically records potential incidents when activated by sound (horns, clashing metal, squealing tires, etc.). The purpose is to detect patterns of crashes at...
Establishing an Agency Records Management Program.
ERIC Educational Resources Information Center
New York State Education Dept., Albany. State Archives and Records Administration.
The New York State Archives and Records Administration (SARA) provides centralized records management services to State agencies. The State Government Records Management Information Series includes booklets and brochures on many aspects of sound records and information management. This booklet explains the purposes and benefits of records…
Kothari, Bhaveshkumar H; Fahmy, Raafat; Claycamp, H Gregg; Moore, Christine M V; Chatterjee, Sharmista; Hoag, Stephen W
2017-05-01
The goal of this study was to utilize risk assessment techniques and statistical design of experiments (DoE) to gain process understanding and to identify critical process parameters for the manufacture of controlled release multiparticulate beads using a novel disk-jet fluid bed technology. The material attributes and process parameters were systematically assessed using the Ishikawa fish bone diagram and failure mode and effect analysis (FMEA) risk assessment methods. The high risk attributes identified by the FMEA analysis were further explored using resolution V fractional factorial design. To gain an understanding of the processing parameters, a resolution V fractional factorial study was conducted. Using knowledge gained from the resolution V study, a resolution IV fractional factorial study was conducted; the purpose of this IV study was to identify the critical process parameters (CPP) that impact the critical quality attributes and understand the influence of these parameters on film formation. For both studies, the microclimate, atomization pressure, inlet air volume, product temperature (during spraying and curing), curing time, and percent solids in the coating solutions were studied. The responses evaluated were percent agglomeration, percent fines, percent yield, bead aspect ratio, median particle size diameter (d50), assay, and drug release rate. Pyrobuttons® were used to record real-time temperature and humidity changes in the fluid bed. The risk assessment methods and process analytical tools helped to understand the novel disk-jet technology and to systematically develop models of the coating process parameters like process efficiency and the extent of curing during the coating process.
Smith, Cory M; Housh, Terry J; Herda, Trent J; Zuniga, Jorge M; Ryan, Eric D; Camic, Clayton L; Bergstrom, Haley C; Smith, Doug B; Weir, Joseph P; Cramer, Joel T; Hill, Ethan C; Cochrane, Kristen C; Jenkins, Nathaniel D M; Schmidt, Richard J; Johnson, Glen O
2015-08-01
The purposes of the present study were to examine the effects of electrode placements over, proximal, and distal to the innervation zone (IZ) on electromyographic (EMG) amplitude (RMS) and frequency (MPF) responses during: (1) a maximal voluntary isometric contraction (MVIC), and; (2) a sustained, submaximal isometric muscle action. A linear array was used to record EMG signals from the vastus lateralis over the IZ, 30mm proximal, and 30mm distal to the IZ during an MVIC and a sustained isometric muscle action of the leg extensors at 50% MVIC. During the MVIC, lower EMG RMS (p>0.05) and greater EMG MPF (p<0.05) values were recorded over the IZ compared to away from the IZ, however, no differences in slope coefficients for the EMG RMS and MPF versus time relationships over, proximal, and distal to the IZ occurred. Thus, the results of the present study indicated that during an MVIC, EMG RMS and MPF values recorded over the IZ are not comparable to those away from the IZ. However, the rates of fatigue-induced changes in EMG RMS and MPF during sustained, submaximal isometric muscle actions of the leg extensors were the same regardless of the electrode placement locations relative to the IZ. Copyright © 2015 Elsevier Ltd. All rights reserved.
Motion analysis for duplicate frame removal in wireless capsule endoscope
NASA Astrophysics Data System (ADS)
Lee, Hyun-Gyu; Choi, Min-Kook; Lee, Sang-Chul
2011-03-01
Wireless capsule endoscopy (WCE) has been intensively researched recently due to its convenience for diagnosis and extended detection coverage of some diseases. Typically, a full recording covering entire human digestive system requires about 8 to 12 hours for a patient carrying a capsule endoscope and a portable image receiver/recorder unit, which produces 120,000 image frames on average. In spite of the benefits of close examination, WCE based test has a barrier for quick diagnosis such that a trained diagnostician must examine a huge amount of images for close investigation, normally over 2 hours. The main purpose of our work is to present a novel machine vision approach to reduce diagnosis time by automatically detecting duplicated recordings caused by backward camera movement, typically containing redundant information, in small intestine. The developed technique could be integrated with a visualization tool which supports intelligent inspection method, such as automatic play speed control. Our experimental result shows high accuracy of the technique by detecting 989 duplicate image frames out of 10,000, equivalently to 9.9% data reduction, in a WCE video from a real human subject. With some selected parameters, we achieved the correct detection ratio of 92.85% and the false detection ratio of 13.57%.
A smart health monitoring chair for nonintrusive measurement of biological signals.
Baek, Hyun Jae; Chung, Gih Sung; Kim, Ko Keun; Park, Kwang Suk
2012-01-01
We developed nonintrusive methods for simultaneous electrocardiogram, photoplethysmogram, and ballistocardiogram measurements that do not require direct contact between instruments and bare skin. These methods were applied to the design of a diagnostic chair for unconstrained heart rate and blood pressure monitoring purposes. Our methods were operationalized through capacitively coupled electrodes installed in the chair back that include high-input impedance amplifiers, and conductive textiles installed in the seat for capacitive driven-right-leg circuit configuration that is capable of recording electrocardiogram information through clothing. Photoplethysmograms were measured through clothing using seat mounted sensors with specially designed amplifier circuits that vary in light intensity according to clothing type. Ballistocardiograms were recorded using a film type transducer material, polyvinylidenefluoride (PVDF), which was installed beneath the seat cover. By simultaneously measuring signals, beat-to-beat heart rates could be monitored even when electrocardiograms were not recorded due to movement artifacts. Beat-to-beat blood pressure was also monitored using unconstrained measurements of pulse arrival time and other physiological parameters, and our experimental results indicated that the estimated blood pressure tended to coincide with actual blood pressure measurements. This study demonstrates the feasibility of our method and device for biological signal monitoring through clothing for unconstrained long-term daily health monitoring that does not require user awareness and is not limited by physical activity.
State of Kansas traffic records assessment : March 21-25, 2005
DOT National Transportation Integrated Search
2005-01-01
The scope of this traffic records assessment included all of the data systems comprising a traffic records system. The purpose of this assessment is to determine whether Kansass traffic records system is capable of supporting managements needs ...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-06
... Subpart A--General. Sec. 707.11 Scope and purpose. Sec. 707.12 Definitions. Sec. 707.13 Preservation of records. Subpart B--Requests for access to records; amendment of records, accounting of disclosures.... Sec. 707.23 Requests for amendment of records. Sec. 707.24 Requests for an accounting of record...
Characterization, parameter estimation, and aircraft response statistics of atmospheric turbulence
NASA Technical Reports Server (NTRS)
Mark, W. D.
1981-01-01
A nonGaussian three component model of atmospheric turbulence is postulated that accounts for readily observable features of turbulence velocity records, their autocorrelation functions, and their spectra. Methods for computing probability density functions and mean exceedance rates of a generic aircraft response variable are developed using nonGaussian turbulence characterizations readily extracted from velocity recordings. A maximum likelihood method is developed for optimal estimation of the integral scale and intensity of records possessing von Karman transverse of longitudinal spectra. Formulas for the variances of such parameter estimates are developed. The maximum likelihood and least-square approaches are combined to yield a method for estimating the autocorrelation function parameters of a two component model for turbulence.
Code of Federal Regulations, 2010 CFR
2010-07-01
... and evaluative purposes, it is impossible to determine in advance what information might be of... Records, USPS 100.300; Personnel Research Records, 100.600; and Emergency Management Records, USPS 500.300...
Code of Federal Regulations, 2013 CFR
2013-07-01
... and evaluative purposes, it is impossible to determine in advance what information might be of... Records, USPS 100.300; Personnel Research Records, 100.600; and Emergency Management Records, USPS 500.300...
Code of Federal Regulations, 2014 CFR
2014-07-01
... and evaluative purposes, it is impossible to determine in advance what information might be of... Records, USPS 100.300; Personnel Research Records, 100.600; and Emergency Management Records, USPS 500.300...
Code of Federal Regulations, 2011 CFR
2011-07-01
... and evaluative purposes, it is impossible to determine in advance what information might be of... Records, USPS 100.300; Personnel Research Records, 100.600; and Emergency Management Records, USPS 500.300...
Code of Federal Regulations, 2012 CFR
2012-07-01
... and evaluative purposes, it is impossible to determine in advance what information might be of... Records, USPS 100.300; Personnel Research Records, 100.600; and Emergency Management Records, USPS 500.300...
Stabilometric parameters are affected by anthropometry and foot placement.
Chiari, Lorenzo; Rocchi, Laura; Cappello, Angelo
2002-01-01
To recognize and quantify the influence of biomechanical factors, namely anthropometry and foot placement, on the more common measures of stabilometric performance, including new-generation stochastic parameters. Fifty normal-bodied young adults were selected in order to cover a sufficiently wide range of anthropometric properties. They were allowed to choose their preferred side-by-side foot position and their quiet stance was recorded with eyes open and closed by a force platform. biomechanical factors are known to influence postural stability but their impact on stabilometric parameters has not been extensively explored yet. Principal component analysis was used for feature selection among several biomechanical factors. A collection of 55 stabilometric parameters from the literature was estimated from the center-of-pressure time series. Linear relations between stabilometric parameters and selected biomechanical factors were investigated by robust regression techniques. The feature selection process returned height, weight, maximum foot width, base-of-support area, and foot opening angle as the relevant biomechanical variables. Only eleven out of the 55 stabilometric parameters were completely immune from a linear dependence on these variables. The remaining parameters showed a moderate to high dependence that was strengthened upon eye closure. For these parameters, a normalization procedure was proposed, to remove what can well be considered, in clinical investigations, a spurious source of between-subject variability. Care should be taken when quantifying postural sway through stabilometric parameters. It is suggested as a good practice to include some anthropometric measurements in the experimental protocol, and to standardize or trace foot position. Although the role of anthropometry and foot placement has been investigated in specific studies, there are no studies in the literature that systematically explore the relationship between such BF and stabilometric parameters. This knowledge may contribute to better defining the experimental protocol and improving the functional evaluation of postural sway for clinical purposes, e.g. by removing through normalization the spurious effects of body properties and foot position on postural performance.
36 CFR 703.1 - Purpose and scope of this subpart.
Code of Federal Regulations, 2010 CFR
2010-07-01
... subpart. 703.1 Section 703.1 Parks, Forests, and Public Property LIBRARY OF CONGRESS DISCLOSURE OR PRODUCTION OF RECORDS OR INFORMATION Availability of Library of Congress Records § 703.1 Purpose and scope of this subpart. (a) This subpart implements the policy of the Library with respect to the public...
36 CFR 703.1 - Purpose and scope of this subpart.
Code of Federal Regulations, 2014 CFR
2014-07-01
... subpart. 703.1 Section 703.1 Parks, Forests, and Public Property LIBRARY OF CONGRESS DISCLOSURE OR PRODUCTION OF RECORDS OR INFORMATION Availability of Library of Congress Records § 703.1 Purpose and scope of this subpart. (a) This subpart implements the policy of the Library with respect to the public...
36 CFR 703.1 - Purpose and scope of this subpart.
Code of Federal Regulations, 2012 CFR
2012-07-01
... subpart. 703.1 Section 703.1 Parks, Forests, and Public Property LIBRARY OF CONGRESS DISCLOSURE OR PRODUCTION OF RECORDS OR INFORMATION Availability of Library of Congress Records § 703.1 Purpose and scope of this subpart. (a) This subpart implements the policy of the Library with respect to the public...
36 CFR 703.1 - Purpose and scope of this subpart.
Code of Federal Regulations, 2011 CFR
2011-07-01
... subpart. 703.1 Section 703.1 Parks, Forests, and Public Property LIBRARY OF CONGRESS DISCLOSURE OR PRODUCTION OF RECORDS OR INFORMATION Availability of Library of Congress Records § 703.1 Purpose and scope of this subpart. (a) This subpart implements the policy of the Library with respect to the public...
45 CFR 2543.50 - Purpose of reports and records.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 45 Public Welfare 4 2012-10-01 2012-10-01 false Purpose of reports and records. 2543.50 Section 2543.50 Public Welfare Regulations Relating to Public Welfare (Continued) CORPORATION FOR NATIONAL AND COMMUNITY SERVICE GRANTS AND AGREEMENTS WITH INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements...
43 CFR 12.950 - Purpose of reports and records.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 43 Public Lands: Interior 1 2011-10-01 2011-10-01 false Purpose of reports and records. 12.950 Section 12.950 Public Lands: Interior Office of the Secretary of the Interior ADMINISTRATIVE AND AUDIT REQUIREMENTS AND COST PRINCIPLES FOR ASSISTANCE PROGRAMS Uniform Administrative Requirements for Grants and Agreements With Institutions of Higher...
A Sensitivity Analysis of Tsunami Inversions on the Number of Stations
NASA Astrophysics Data System (ADS)
An, Chao; Liu, Philip L.-F.; Meng, Lingsen
2018-05-01
Current finite-fault inversions of tsunami recordings generally adopt as many tsunami stations as possible to better constrain earthquake source parameters. In this study, inversions are evaluated by the waveform residual that measures the difference between model predictions and recordings, and the dependence of the quality of inversions on the number tsunami stations is derived. Results for the 2011 Tohoku event show that, if the tsunami stations are optimally located, the waveform residual decreases significantly with the number of stations when the number is 1 ˜ 4 and remains almost constant when the number is larger than 4, indicating that 2 ˜ 4 stations are able to recover the main characteristics of the earthquake source. The optimal location of tsunami stations is explained in the text. Similar analysis is applied to the Manila Trench in the South China Sea using artificially generated earthquakes and virtual tsunami stations. Results confirm that 2 ˜ 4 stations are necessary and sufficient to constrain the earthquake source parameters, and the optimal sites of stations are recommended in the text. The conclusion is useful for the design of new tsunami warning systems. Current strategies of tsunameter network design mainly focus on the early detection of tsunami waves from potential sources to coastal regions. We therefore recommend that, in addition to the current strategies, the waveform residual could also be taken into consideration so as to minimize the error of tsunami wave prediction for warning purposes.
Zhu, Ye-Hua; Wang, Xun; Zhang, Jin; Chen, Yong-Hui; Kong, Wen; Huang, Yi-Ran
2014-09-01
The purpose of this study was to assess the relation between tumor enhancement on multiphase contrast-enhanced CT images and Fuhrman grade of clear cell renal cell carcinoma. A single-institution retrospective review was conducted on the records of 255 patients who underwent radical or partial nephrectomy and received a histologic diagnosis of clear cell renal cell carcinoma. Two radiologists recorded the radiographic features of each patient, including the attenuation value of the lesion, lesion size, calcification within the lesion, cystic versus solid appearance, and margin regularity. Parameters representing the extent of tumor enhancement were defined and calculated. The association between tumor enhancement and Fuhrman grade was analyzed, and multivariate analysis was performed to find independent predictors of high tumor grade. Significant differences existed in tumor enhancement among different Fuhrman grades (p < 0.001). High-grade tumors had significantly lower enhancement (p < 0.001). The enhancement parameter had a sensitivity of 0.84 and specificity of 0.93 in prediction of high tumor grade. In the multivariate analysis, more advanced age, irregular margin, and low tumor enhancement were the three independent predictors of high tumor grade. Tumor enhancement of clear cell renal cell carcinoma on multiphase contrast-enhanced CT images is associated with Fuhrman grade. Low tumor enhancement in the corticomedullary phase is an independent predictor of high tumor grade. This system may be helpful in clinical decision making about the care of patients treated by nonsurgical approaches.
[A personal computer-based system for online monitoring of neurologic intensive care patients].
Stoll, M; Hamann, G; Jost, V; Schimrigk, K
1992-03-01
In the management of neurological intensive care patients with an intracranial space-consuming process the measurement and recording of intracranial pressure together with arterial blood pressure is of special interest. These parameters can be used to monitor the treatment of brain edema and hypertension. Intracranial pressure measurement is also important in the diagnosis of the various subtypes of hydrocephalus. Not only the absolute figures, but also the recognition of specific pressure-patterns is of particular clinical and scientific interest. This new, easily installed and inexpensive system comprises a PC and a conventional monitor, which are connected by an AD-conversion card. Our software, specially developed for this system demonstrates, stores and prints the online-course and the trend of the measurements. In addition it is also possible to view the online-course of conspicuous parts of the trend curve retrospectively and to use these values for statistical analyses. Object-orientated software development techniques were used for flexible graphic output on the screen, printer or to a file. Though developed for this specific purpose, this system is also suitable for recording continuous, longer-term measurements in general.
Object-based image analysis for cadastral mapping using satellite images
NASA Astrophysics Data System (ADS)
Kohli, D.; Crommelinck, S.; Bennett, R.; Koeva, M.; Lemmen, C.
2017-10-01
Cadasters together with land registry form a core ingredient of any land administration system. Cadastral maps comprise of the extent, ownership and value of land which are essential for recording and updating land records. Traditional methods for cadastral surveying and mapping often prove to be labor, cost and time intensive: alternative approaches are thus being researched for creating such maps. With the advent of very high resolution (VHR) imagery, satellite remote sensing offers a tremendous opportunity for (semi)-automation of cadastral boundaries detection. In this paper, we explore the potential of object-based image analysis (OBIA) approach for this purpose by applying two segmentation methods, i.e. MRS (multi-resolution segmentation) and ESP (estimation of scale parameter) to identify visible cadastral boundaries. Results show that a balance between high percentage of completeness and correctness is hard to achieve: a low error of commission often comes with a high error of omission. However, we conclude that the resulting segments/land use polygons can potentially be used as a base for further aggregation into tenure polygons using participatory mapping.
NASA Astrophysics Data System (ADS)
Rahman, Nur Aira Abd; Yussup, Nolida; Salim, Nazaratul Ashifa Bt. Abdullah; Ibrahim, Maslina Bt. Mohd; Mokhtar, Mukhlis B.; Soh@Shaari, Syirrazie Bin Che; Azman, Azraf B.; Ismail, Nadiah Binti
2015-04-01
Neutron Activation Analysis (NAA) had been established in Nuclear Malaysia since 1980s. Most of the procedures established were done manually including sample registration. The samples were recorded manually in a logbook and given ID number. Then all samples, standards, SRM and blank were recorded on the irradiation vial and several forms prior to irradiation. These manual procedures carried out by the NAA laboratory personnel were time consuming and not efficient. Sample registration software is developed as part of IAEA/CRP project on `Development of Process Automation in the Neutron Activation Analysis (NAA) Facility in Malaysia Nuclear Agency (RC17399)'. The objective of the project is to create a pc-based data entry software during sample preparation stage. This is an effective method to replace redundant manual data entries that needs to be completed by laboratory personnel. The software developed will automatically generate sample code for each sample in one batch, create printable registration forms for administration purpose, and store selected parameters that will be passed to sample analysis program. The software is developed by using National Instruments Labview 8.6.
Generalized extreme gust wind speeds distributions
Cheng, E.; Yeung, C.
2002-01-01
Since summer 1996, the US wind engineers are using the extreme gust (or 3-s gust) as the basic wind speed to quantify the destruction of extreme winds. In order to better understand these destructive wind forces, it is important to know the appropriate representations of these extreme gust wind speeds. Therefore, the purpose of this study is to determine the most suitable extreme value distributions for the annual extreme gust wind speeds recorded in large selected areas. To achieve this objective, we are using the generalized Pareto distribution as the diagnostic tool for determining the types of extreme gust wind speed distributions. The three-parameter generalized extreme value distribution function is, thus, reduced to either Type I Gumbel, Type II Frechet or Type III reverse Weibull distribution function for the annual extreme gust wind speeds recorded at a specific site.With the considerations of the quality and homogeneity of gust wind data collected at more than 750 weather stations throughout the United States, annual extreme gust wind speeds at selected 143 stations in the contiguous United States were used in the study. ?? 2002 Elsevier Science Ltd. All rights reserved.
Laryngeal aerodynamics associated with oral contraceptive use: preliminary findings.
Gorham-Rowan, Mary; Fowler, Linda
2009-01-01
The purpose of this study was to examine possible differences in laryngeal aerodynamic measures during connected speech associated with oral contraceptive (OC) use. Eight women taking an OC, and eight others not taking an OC, participated in the study. Three trials of syllable /p/repetitions were obtained using a circumferentially vented face mask and small translabial tube. All participants were recorded on or near days 7 and 14 of their menstrual cycle. Subglottal pressure (P(SG)) and average airflow rates were obtained to determine laryngeal airway resistance. Glottal airflow measures of peak flow, minimum flow, alternating flow, as well as relative sound level (RSL) were obtained. P(SG) was obtained from the pressure peak associated with/p/. All airflow parameters and RSL were obtained from the vowel portion. No significant differences were found related to day of recording or OC use, indicating that OC use does not significantly affect laryngeal airflow regulation. The reader will better understand the effects of hormones and oral contraceptives on the female voice, as well as the specific changes in vocal function that may occur in conjunction with the use of oral contraceptives.
NASA Astrophysics Data System (ADS)
Ren, Yefei; Wen, Ruizhi; Yao, Xinxin; Ji, Kun
2017-08-01
The consideration of soil nonlinearity is important for the accurate estimation of the site response. To evaluate the soil nonlinearity during the 2008 Ms8.0 Wenchuan Earthquake, 33 strong-motion records obtained from the main shock and 890 records from 157 aftershocks were collected for this study. The horizontal-to-vertical spectral ratio (HVSR) method was used to calculate five parameters: the ratio of predominant frequency (RFp), degree of nonlinearity (DNL), absolute degree of nonlinearity (ADNL), frequency of nonlinearity (fNL), and percentage of nonlinearity (PNL). The purpose of this study was to evaluate the soil nonlinearity level of 33 strong-motion stations and to investigate the characteristics, performance, and effective usage of these five parameters. Their correlations with the peak ground acceleration (PGA), peak ground velocity (PGV), average uppermost 30-m shear-wave velocity ( V S30), and maximum amplitude of HVSR ( A max) were investigated. The results showed that all five parameters correlate well with PGA and PGV. The DNL, ADNL, and PNL also show a good correlation with A max, which means that the degree of soil nonlinearity not only depends on the ground-motion amplitude (e.g., PGA and PGV) but also on the site condition. The fNL correlates with PGA and PGV but shows no correlation with either A max or V S30, implying that the frequency width affected by the soil nonlinearity predominantly depends on the ground-motion amplitude rather than the site condition. At 16 of the 33 stations analyzed in this study, the site response showed evident (i.e., strong and medium) nonlinearity during the main shock of the Wenchuan Earthquake, where the ground-motion level was almost beyond the threshold of PGA > 200 cm/s2 or PGV > 15 cm/s. The site response showed weak and no nonlinearity at the other 14 and 3 stations. These results also confirm that RFp, DNL, ADNL, and PNL are effective in identifying the soil nonlinearity behavior. The identification results vary for different parameters because each parameter has individual features. The performance of the PNL was better than that of DNL and ADNL in this case study. The thresholds of ADNL and PNL are proposed to be 2.0 and 7%, respectively.[Figure not available: see fulltext.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 41 Public Contracts and Property Management 3 2011-01-01 2011-01-01 false Records. 109-38.902... 38-MOTOR EQUIPMENT MANAGEMENT 38.9-Federal Motor Vehicle Fleet Report § 109-38.902 Records. The... adequate records for accounting and reporting purposes. ...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 41 Public Contracts and Property Management 3 2014-01-01 2014-01-01 false Records. 109-38.902... 38-MOTOR EQUIPMENT MANAGEMENT 38.9-Federal Motor Vehicle Fleet Report § 109-38.902 Records. The... adequate records for accounting and reporting purposes. ...
Privacy Act System of Records: Medical and Research Study Records of Human Volunteers, EPA-34
Learn about the Medical and Research Study Records of Human Volunteers System, including who is covered in the system, the purpose of data collection, routine uses for the system's records, and other security procedures.
Open access intrapartum CTG database.
Chudáček, Václav; Spilka, Jiří; Burša, Miroslav; Janků, Petr; Hruban, Lukáš; Huptych, Michal; Lhotská, Lenka
2014-01-13
Cardiotocography (CTG) is a monitoring of fetal heart rate and uterine contractions. Since 1960 it is routinely used by obstetricians to assess fetal well-being. Many attempts to introduce methods of automatic signal processing and evaluation have appeared during the last 20 years, however still no significant progress similar to that in the domain of adult heart rate variability, where open access databases are available (e.g. MIT-BIH), is visible. Based on a thorough review of the relevant publications, presented in this paper, the shortcomings of the current state are obvious. A lack of common ground for clinicians and technicians in the field hinders clinically usable progress. Our open access database of digital intrapartum cardiotocographic recordings aims to change that. The intrapartum CTG database consists in total of 552 intrapartum recordings, which were acquired between April 2010 and August 2012 at the obstetrics ward of the University Hospital in Brno, Czech Republic. All recordings were stored in electronic form in the OB TraceVue®;system. The recordings were selected from 9164 intrapartum recordings with clinical as well as technical considerations in mind. All recordings are at most 90 minutes long and start a maximum of 90 minutes before delivery. The time relation of CTG to delivery is known as well as the length of the second stage of labor which does not exceed 30 minutes. The majority of recordings (all but 46 cesarean sections) is - on purpose - from vaginal deliveries. All recordings have available biochemical markers as well as some more general clinical features. Full description of the database and reasoning behind selection of the parameters is presented in the paper. A new open-access CTG database is introduced which should give the research community common ground for comparison of results on reasonably large database. We anticipate that after reading the paper, the reader will understand the context of the field from clinical and technical perspectives which will enable him/her to use the database and also understand its limitations.
Experimental Study on Strength Evaluation Applied for Teeth Extraction: An In Vivo Study
Cicciù, Marco; Bramanti, Ennio; Signorino, Fabrizio; Cicciù, Alessandra; Sortino, Francesco
2013-01-01
Purpose: The aim of this work was to analyse all the applied movements when extracting healthy upper and lower jaw premolars for orthodontic purposes. The authors wanted to demonstrate that the different bone densities of the mandible and maxilla are not a significant parameter when related to the extraction force applied. The buccal and palatal rocking movements, plus the twisting movements were also measured in this in-vivo study during premolar extraction for orthodontic purposes. Methods: The physical strains or forces transferred onto the teeth during extraction are the following three movements: gripping, twisting, and traction. A strain measurement gauge was attached onto an ordinary dentistry plier. The strain measurement gauge was constituted with an extensimetric washer with three 45º grids. The system operation was correlated to the variation of electrical resistance. Results: The variations of resistance (∆R) and all the different forces applied to the teeth (∆V) were recorded by a computerized system. Data results were processed through Microsoft Excel. The results underlined the stress distribution on the extracted teeth during gripping, twisting and flexion. Conclusions: The obtained data showed that the strength required to effect teeth extraction is not influenced by the quality of the bone but is instead influenced by the shape of the tooth’s root. PMID:23539609
Kukke, Sahana N; Paine, Rainer W; Chao, Chi-Chao; de Campos, Ana C; Hallett, Mark
2014-06-01
The purpose of this study is to develop a method to reliably characterize multiple features of the corticospinal system in a more efficient manner than typically done in transcranial magnetic stimulation studies. Forty transcranial magnetic stimulation pulses of varying intensity were given over the first dorsal interosseous motor hot spot in 10 healthy adults. The first dorsal interosseous motor-evoked potential size was recorded during rest and activation to create recruitment curves. The Boltzmann sigmoidal function was fit to the data, and parameters relating to maximal motor-evoked potential size, curve slope, and stimulus intensity leading to half-maximal motor-evoked potential size were computed from the curve fit. Good to excellent test-retest reliability was found for all corticospinal parameters at rest and during activation with 40 transcranial magnetic stimulation pulses. Through the use of curve fitting, important features of the corticospinal system can be determined with fewer stimuli than typically used for the same information. Determining the recruitment curve provides a basis to understand the state of the corticospinal system and select subject-specific parameters for transcranial magnetic stimulation testing quickly and without unnecessary exposure to magnetic stimulation. This method can be useful in individuals who have difficulty in maintaining stillness, including children and patients with motor disorders.
Identification of temporal pathomechanical factors during the tennis serve.
Martin, Caroline; Kulpa, Richard; Ropars, Mickaël; Delamarche, Paul; Bideau, Benoit
2013-11-01
The purpose of this study was twofold: (a) to measure the effects of temporal parameters on both ball velocity and upper limb joint kinetics to identify pathomechanical factors during the tennis serve and (b) to validate these pathomechanical factors by comparing injured and noninjured players. The serves of expert tennis players were recorded with an optoelectronic motion capture system. These experts were then followed during two seasons to identify overuse injuries of the upper limb. Correlation coefficients assessed the relationships between temporal parameters, ball velocity, and peaks of upper limb joint kinetics to identify pathomechanical factors. Temporal parameters and ball velocity were compared between injured and noninjured groups. Temporal pathomechanical factors were identified. The timings of peak angular velocities of pelvis longitudinal rotation, upper torso longitudinal rotation, trunk sagittal rotation, and trunk transverse rotation and the duration between instants of shoulder horizontal adduction and external rotation were significantly related to upper limb joint kinetics and ball velocity. Injured players demonstrated later timings of trunk rotations, improper differences in time between instants of shoulder horizontal adduction and external rotation, lower ball velocities, and higher joint kinetics. The findings of this study imply that improper temporal mechanics during the tennis serve can decrease ball velocity, increase upper limb joint kinetics, and thus possibly increase overuse injuries of the upper limb.
Angular photogrammetric comparison of the soft-tissue facial profile of Kenyans and Chinese.
Wamalwa, Peter; Amisi, Stella Kabarika; Wang, Yunji; Chen, Song
2011-05-01
The purpose of this study was to determine the average angular dimensions that define the normal soft-tissue facial profiles of black Kenyans and Chinese and compare them with each other and with values proposed for whites. Standardized facial profile photographs, taken in natural head position, of 177 black Kenyans and 156 Chinese with normal occlusion and well-balanced faces were analyzed for 12 angular parameters. Two-sample t-tests were used to determine sex and racial differences. Kenyan and Chinese averages were compared with proposed white values using 1-sample t-tests. Eight parameters in Kenyans and 7 in Chinese showed sex differences. All angles, except for facial convexity, nasal dorsum, and inferior facial height, were different between Kenyans and Chinese. Kenyan and Chinese averages for all parameters were different from proposed white average, except for facial convexity. Nasolabial and mentolabial angles showed large individual variability and racial differences. The study demonstrated many differences in average angular measurements of the facial profiles of black Kenyans, Chinese, and white standards. Orthodontists, maxillofacial and plastic surgeons, and other clinicians working in the craniofacial region should bear these in mind when setting aesthetic treatment goals for patients of different races. Mean values from this study can be used for comparison with similar records of subjects with same ethnicity.
NASA Astrophysics Data System (ADS)
Madlazim; Prastowo, T.; Supardiyono; Hardy, T.
2018-03-01
Monitoring of volcanoes has been an important issue for many purposes, particularly hazard mitigation. With regard to this, the aims of the present work are to estimate and analyse source parameters of a volcanic earthquake driven by recent magmatic events of Mount Agung in Bali island that occurred on September 28, 2017. The broadband seismogram data consisting of 3 local component waveforms were recorded by the IA network of 5 seismic stations: SRBI, DNP, BYJI, JAGI, and TWSI (managed by BMKG). These land-based observatories covered a full 4-quadrant region surrounding the epicenter. The methods used in the present study were seismic moment-tensor inversions, where the data were all analyzed to extract the parameters, namely moment magnitude, type of a volcanic earthquake indicated by percentages of seismic components: compensated linear vector dipole (CLVD), isotropic (ISO), double-couple (DC), and source depth. The results are given in the forms of variance reduction of 65%, a magnitude of M W 3.6, a CLVD of 40%, an ISO of 33%, a DC of 27% and a centroid-depth of 9.7 km. These suggest that the unusual earthquake was dominated by a vertical CLVD component, implying the dominance of uplift motion of magmatic fluid flow inside the volcano.
Szyperski, Piotr D
2018-06-01
The purpose of this research was to evaluate the applicability of the fractal dimension (FD) estimators to assess lateral shearing interferometric (LSI) measurements of tear film surface quality. Retrospective recordings of tear film measured with LSI were used: 69 from healthy subjects and 41 from patients diagnosed with dry eye syndrome. Five surface quality descriptors were considered, four based on FD and a previously reported descriptor operating in a spatial frequency domain (M 2 ), presenting temporal kinetics of post-blink tear film. A set of 12 regression parameters has been extracted and analyzed for classification purposes. The classifiers are assessed in terms of receiver operating characteristics and areas under their curves (AUC). Also, the computational loads are estimated. The maximum AUC of 82.4% was achieved for M 2 , closely followed by the binary box-counting (BBC) FD estimator with AUC=78.6%. For all descriptors, statistically significant differences between the subject groups were found (p<0.05). The BBC FD estimator was characterized with the highest empirical computational efficiency that was about 30% faster than that of M 2 , while that based on the differential box-counting exhibited the lowest efficiency (4.5 times slower than the best one). Concluding, FD estimators can be utilized for quantitative assessment of tear film kinetics. They provide a viable alternative to previously used spectral counter parameters, and at the same time allow higher computational efficiency.
76 FR 12549 - Public Availability of Government Accountability Office Records
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-08
... agency for law enforcement purposes. * * * * * (m) * * * Records obtained by the GAO Forensic Audits and... collects, during the course of its audits and investigations, records from law enforcement agencies that...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Banic, A.; Kouris, K.; Lewis, D.H.
1990-10-01
The aim of the study was experimentally to evaluate the capability and reliability of laser Doppler flowmetry (LDF) in conditions of circulatory deficiency, by correlating it to flow-related parameters measured by a radionuclide-imaging technique and using 99m-Tc red blood cells (RBCs). For this purpose, a pedicle island flap in the sheep was used, with well-perfused proximal parts and with evident stasis in the distal third of the flap. No correlation was found between results obtained with the two techniques. In regions with evident stasis, falsely high LDF readings were recorded. This may be due to a back-and-forth motion of themore » RBCs under the probe, rather than to true flow. It was concluded that, while LDF seems reliable in detecting complete arterial occlusion, it is unreliable in predicting either complete venous occlusion or partial obstruction of the flow to and from the flap. Clinical use for this purpose cannot be recommended.« less
36 CFR 1290.6 - Originals and copies.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Section 1290.6 Parks, Forests, and Public Property NATIONAL ARCHIVES AND RECORDS ADMINISTRATION JFK... ASSASSINATION RECORDS COLLECTION ACT OF 1992 (JFK ACT) § 1290.6 Originals and copies. (a) For purposes of.... Kennedy Assassination Records Collection (JFK Assassination Records Collection) established under the JFK...
36 CFR 1290.6 - Originals and copies.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Section 1290.6 Parks, Forests, and Public Property NATIONAL ARCHIVES AND RECORDS ADMINISTRATION JFK... ASSASSINATION RECORDS COLLECTION ACT OF 1992 (JFK ACT) § 1290.6 Originals and copies. (a) For purposes of.... Kennedy Assassination Records Collection (JFK Assassination Records Collection) established under the JFK...
36 CFR 1290.6 - Originals and copies.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Section 1290.6 Parks, Forests, and Public Property NATIONAL ARCHIVES AND RECORDS ADMINISTRATION JFK... ASSASSINATION RECORDS COLLECTION ACT OF 1992 (JFK ACT) § 1290.6 Originals and copies. (a) For purposes of.... Kennedy Assassination Records Collection (JFK Assassination Records Collection) established under the JFK...
8 CFR 103.40 - Genealogical Research Requests.
Code of Federal Regulations, 2012 CFR
2012-01-01
... BENEFITS; BIOMETRIC REQUIREMENTS; AVAILABILITY OF RECORDS Availability of Records § 103.40 Genealogical... historical records relating to a deceased person, usually for genealogy and family history research purposes. (b) Manner of requesting genealogical searches and records. Requests must be submitted on Form G-1041...
8 CFR 103.40 - Genealogical Research Requests.
Code of Federal Regulations, 2013 CFR
2013-01-01
... BENEFITS; BIOMETRIC REQUIREMENTS; AVAILABILITY OF RECORDS Availability of Records § 103.40 Genealogical... historical records relating to a deceased person, usually for genealogy and family history research purposes. (b) Manner of requesting genealogical searches and records. Requests must be submitted on Form G-1041...
Determination of surface layer parameters at the edge of a suburban area
NASA Astrophysics Data System (ADS)
Likso, T.; Pandžić, K.
2012-05-01
Vertical wind and air temperature profile related parameters in the surface layer at the edge of suburban area of Zagreb (Croatia) have been considered. For that purpose, adopted Monin-Obukhov similarity theory and a set of observations of wind and air temperature at 2 and 10 m above ground, recorded in 2005, have been used. The root mean square differences (errors) principle has been used as a tool to estimate the effective roughness length as well as standard deviations of wind speed and wind gusts. The results of estimation are effective roughness lengths dependent on eight wind direction sectors unknown before. Gratefully to that achievement, representativeness of wind data at standard 10-m height can be clarified more deeply for an area of at least about 1 km in upwind direction from the observation site. Extrapolation of wind data for lower or higher levels from standard 10-m height are thus properly representative for a wider inhomogeneous suburban area and can be used as such in numerical models, flux and wind energy estimation, civil engineering, air pollution and climatological applications.
Markessis, Emily; Poncelet, Luc; Colin, Cécile; Hoonhorst, Ingrid; Collet, Grégory; Deltenre, Paul; Moore, Brian C J
2010-06-01
Auditory steady-state evoked potential (ASSEP) tuning curves were compared to compound action potential (CAP) tuning curves, both measured at 2 Hz, using sedated beagle puppies. The effect of two types of masker (narrowband noise and sinusoidal) on the tuning curve parameters was assessed. Whatever the masker type, CAP tuning curve parameters were qualitatively and quantitatively similar to the ASSEP ones, with a similar inter-subject variability, but with a greater incidence of upward tip displacement. Whatever the procedure, sinusoidal maskers produced sharper tuning curves than narrow-band maskers. Although these differences are not likely to have significant implications for clinical work, from a fundamental point of view, their origin requires further investigations. The same amount of time was needed to record a CAP and an ASSEP 13-point tuning curve. The data further validate the ASSEP technique, which has the advantages of having a smaller tendency to produce upward tip shifts than the CAP technique. Moreover, being non invasive, ASSEP tuning curves can be easily repeated over time in the same subject for clinical and research purposes.
Serious games for elderly continuous monitoring.
Lemus-Zúñiga, Lenin-G; Navarro-Pardo, Esperanza; Moret-Tatay, Carmen; Pocinho, Ricardo
2015-01-01
Information technology (IT) and serious games allow older population to remain independent for longer. Hence, when designing technology for this population, developmental changes, such as attention and/or perception, should be considered. For instance, a crucial developmental change has been related to cognitive speed in terms of reaction time (RT). However, this variable presents a skewed distribution that difficult data analysis. An alternative strategy is to characterize the data to an ex-Gaussian function. Furthermore, this procedure provides different parameters that have been related to underlying cognitive processes in the literature. Another issue to be considered is the optimal data recording, storing and processing. For that purpose mobile devices (smart phones and tablets) are a good option for targeting serious games where valuable information can be stored (time spent in the application, reaction time, frequency of use, and a long etcetera). The data stored inside the smartphones and tablets can be sent to a central computer (cloud storage) in order to store the data collected to not only fill the distribution of reaction times to mathematical functions, but also to estimate parameters which may reflect cognitive processes underlying language, aging, and decisional process.
Skrzypczak, M; Szwed, A
2005-01-01
The main purpose of this paper is to describe the variability of the body mass index (BMI) and selected physiological parameters (serum glucose, total serum cholesterol, systolic and diastolic blood pressure) in women before and after menopause. The empirical basis for the assessment is the material obtained in cross-sectional studies carried out in the years 1998-2001 in a group of 2204 women aged 35-65 years, residents of the Wielkopolska region, Poland. The results indicate that hormonal changes taking place in the climacterium bring about an increase in the BMI. It was observed that women receiving Hormone Replacement Therapy in the perimenopause had BMI significantly lower than naturally menopausal women. Increased levels of total serum cholesterol and blood glucose were recorded. The trend has a stronger relation with the age of the subjects than with the character of the menopause. The systolic and diastolic blood pressure values were also found to increase significantly after the menopause, but no relationship with the type of menopause was found.
AQUIRE: Aquatic Toxicity Information Retrieval data base. Data file
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anderson, E.; Pilli, A.
The purpose of Aquatic Toxicity Information Retrieval (AQUIRE) data base is to provide scientists and managers quick access to a comprehensive, systematic, computerized compilation of aquatic toxicity data. Scientific papers published both nationally and internationally on the toxicity of chemicals to aquatic organisms and plants are collected and reviewed for AQUIRE. Independently compiled data files that meet AQUIRE parameter and quality assurance criteria are also included. Selected toxicity-test results and related testing information for any individual chemical from laboratory and field aquatic toxicity tests are extracted and added to AQUIRE. Acute, sublethal, and bioconcentration effects are included for tests withmore » freshwater and marine organisms. The total number of data records in AQUIRE now equals 104,500. This includes data from 6000 references, for 5200 chemicals and 2400 test species. A major data file, Acute Toxicity of Organic Chemicals (ATOC), has been incorporated into AQUIRE. The ATOC file contains laboratory acute test data on 525 organic chemicals using juvenile fathead minnows. The complete data file can be accessed by requesting review code 5 as a search parameter.« less
36 CFR § 703.1 - Purpose and scope of this subpart.
Code of Federal Regulations, 2013 CFR
2013-07-01
... subpart. § 703.1 Section § 703.1 Parks, Forests, and Public Property LIBRARY OF CONGRESS DISCLOSURE OR PRODUCTION OF RECORDS OR INFORMATION Availability of Library of Congress Records § 703.1 Purpose and scope of this subpart. (a) This subpart implements the policy of the Library with respect to the public...
78 FR 14295 - Privacy Act of 1974; System of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-05
.... SUPPLEMENTARY INFORMATION: The Department of the Air Force's notices for systems of records subject to the...: Delete entry and replace with ``10 U.S.C., 8013, Secretary of the Air Force; 10 U.S.C. Sections 885... E.O. 9397 (SSN), as amended.'' Purpose(s): Delete entry and replace with ``To support the Air Force...
Privacy Impact Assessment for the Wellness Program Medical Records
The Wellness Program Medical Records System collects contact information and other Personally Identifiable Information (PII). Learn how this data is collected, used, accessed, the purpose of data collection, and record retention policies.
Joint Inversion of Earthquake Source Parameters with local and teleseismic body waves
NASA Astrophysics Data System (ADS)
Chen, W.; Ni, S.; Wang, Z.
2011-12-01
In the classical source parameter inversion algorithm of CAP (Cut and Paste method, by Zhao and Helmberger), waveform data at near distances (typically less than 500km) are partitioned into Pnl and surface waves to account for uncertainties in the crustal models and different amplitude weight of body and surface waves. The classical CAP algorithms have proven effective for resolving source parameters (focal mechanisms, depth and moment) for earthquakes well recorded on relatively dense seismic network. However for regions covered with sparse stations, it is challenging to achieve precise source parameters . In this case, a moderate earthquake of ~M6 is usually recorded on only one or two local stations with epicentral distances less than 500 km. Fortunately, an earthquake of ~M6 can be well recorded on global seismic networks. Since the ray paths for teleseismic and local body waves sample different portions of the focal sphere, combination of teleseismic and local body wave data helps constrain source parameters better. Here we present a new CAP mothod (CAPjoint), which emploits both teleseismic body waveforms (P and SH waves) and local waveforms (Pnl, Rayleigh and Love waves) to determine source parameters. For an earthquake in Nevada that is well recorded with dense local network (USArray stations), we compare the results from CAPjoint with those from the traditional CAP method involving only of local waveforms , and explore the efficiency with bootstraping statistics to prove the results derived by CAPjoint are stable and reliable. Even with one local station included in joint inversion, accuracy of source parameters such as moment and strike can be much better improved.
Boryshpolets, S; Kowalski, R K; Dietrich, G J; Dzyuba, B; Ciereszko, A
2013-10-15
In this study, we examined different computer-assisted sperm analysis (CASA) systems (CRISMAS, Hobson Sperm Tracker, and Image J CASA) on the exact same video recordings to evaluate the differences in sperm motility parameters related to the specific CASA used. To cover a wide range of sperm motility parameters, we chose 12-second video recordings at 25 and 50 Hz frame rates after sperm motility activation using three taxonomically distinct fish species (sterlet: Acipenser ruthenus L.; common carp: Cyprinus carpio L.; and rainbow trout: Oncorhynchus mykiss Walbaum) that are characterized by essential differences in sperm behavior during motility. Systematically higher values of velocity and beat cross frequency (BCF) were observed in video recordings obtained at 50 Hz frame frequency compared with 25 Hz for all three systems. Motility parameters were affected by the CASA and species used for analyses. Image J and CRISMAS calculated higher curvilinear velocity (VCL) values for rainbow trout and common carp at 25 Hz frequency compared with the Hobson Sperm Tracker, whereas at 50 Hz, a significant difference was observed only for rainbow trout sperm recordings. No significant difference was observed between the CASA systems for sterlet sperm motility at 25 and 50 Hz. Additional analysis of 1-second segments taken at three time points (1, 6, and 12 seconds of the recording) revealed a dramatic decrease in common carp and rainbow trout sperm speed. The motility parameters of sterlet spermatozoa did not change significantly during the 12-second motility period and should be considered as a suitable model for longer motility analyses. Our results indicated that the CASA used can affect motility results even when the same motility recordings are used. These results could be critically altered by the recording quality, time of analysis, and frame rate of camera, and could result in erroneous conclusions. Copyright © 2013 Elsevier Inc. All rights reserved.
Relationships of stroke patients' gait parameters with fear of falling.
Park, Jin; Yoo, Ingyu
2014-12-01
[Purpose] The purpose of this study was to assess the correlation of gait parameters with fear of falling in stroke survivors. [Subjects] In total, 12 patients with stroke participated. [Methods] The subjects performed on a Biodex Gait Trainer 2 for 5 min to evaluate characteristic gait parameters. The kinematic gait parameters measured were gait speed, step cycle, step length, and time on each foot (step symmetry). All the subjects also completed a fall anxiety survey. [Results] Correlations between gait parameters and fear of falling scores were calculated. There was a moderate degree of correlation between fear of falling scores and the step cycle item of gait parameters. [Conclusions] According to our results, the step cycle gait parameter may be related to increased fall anxiety.
20 CFR 402.105 - Exemption seven for withholding records: Law enforcement.
Code of Federal Regulations, 2010 CFR
2010-04-01
... enforcement purposes. The records may apply to actual or potential violations of either criminal or civil laws... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false Exemption seven for withholding records: Law... INFORMATION AND RECORDS TO THE PUBLIC § 402.105 Exemption seven for withholding records: Law enforcement. We...
20 CFR 402.105 - Exemption seven for withholding records: Law enforcement.
Code of Federal Regulations, 2012 CFR
2012-04-01
... enforcement purposes. The records may apply to actual or potential violations of either criminal or civil laws... 20 Employees' Benefits 2 2012-04-01 2012-04-01 false Exemption seven for withholding records: Law... INFORMATION AND RECORDS TO THE PUBLIC § 402.105 Exemption seven for withholding records: Law enforcement. We...
20 CFR 402.105 - Exemption seven for withholding records: Law enforcement.
Code of Federal Regulations, 2013 CFR
2013-04-01
... enforcement purposes. The records may apply to actual or potential violations of either criminal or civil laws... 20 Employees' Benefits 2 2013-04-01 2013-04-01 false Exemption seven for withholding records: Law... INFORMATION AND RECORDS TO THE PUBLIC § 402.105 Exemption seven for withholding records: Law enforcement. We...
20 CFR 402.105 - Exemption seven for withholding records: Law enforcement.
Code of Federal Regulations, 2014 CFR
2014-04-01
... enforcement purposes. The records may apply to actual or potential violations of either criminal or civil laws... 20 Employees' Benefits 2 2014-04-01 2014-04-01 false Exemption seven for withholding records: Law... INFORMATION AND RECORDS TO THE PUBLIC § 402.105 Exemption seven for withholding records: Law enforcement. We...
20 CFR 402.105 - Exemption seven for withholding records: Law enforcement.
Code of Federal Regulations, 2011 CFR
2011-04-01
... enforcement purposes. The records may apply to actual or potential violations of either criminal or civil laws... 20 Employees' Benefits 2 2011-04-01 2011-04-01 false Exemption seven for withholding records: Law... INFORMATION AND RECORDS TO THE PUBLIC § 402.105 Exemption seven for withholding records: Law enforcement. We...
7 CFR 984.80 - Books and other records.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 7 Agriculture 8 2014-01-01 2014-01-01 false Books and other records. 984.80 Section 984.80... Regulating Handling Reports, Books, and Other Records § 984.80 Books and other records. Each handler shall... for the purpose of performing its functions under this subpart. Such books and records shall be...
7 CFR 984.80 - Books and other records.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 8 2011-01-01 2011-01-01 false Books and other records. 984.80 Section 984.80... Regulating Handling Reports, Books, and Other Records § 984.80 Books and other records. Each handler shall... for the purpose of performing its functions under this subpart. Such books and records shall be...
7 CFR 984.80 - Books and other records.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 7 Agriculture 8 2012-01-01 2012-01-01 false Books and other records. 984.80 Section 984.80... Regulating Handling Reports, Books, and Other Records § 984.80 Books and other records. Each handler shall... for the purpose of performing its functions under this subpart. Such books and records shall be...
7 CFR 984.80 - Books and other records.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 8 2010-01-01 2010-01-01 false Books and other records. 984.80 Section 984.80... Regulating Handling Reports, Books, and Other Records § 984.80 Books and other records. Each handler shall... for the purpose of performing its functions under this subpart. Such books and records shall be...
7 CFR 984.80 - Books and other records.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 7 Agriculture 8 2013-01-01 2013-01-01 false Books and other records. 984.80 Section 984.80... Regulating Handling Reports, Books, and Other Records § 984.80 Books and other records. Each handler shall... for the purpose of performing its functions under this subpart. Such books and records shall be...
30 CFR 75.339 - Seals records.
Code of Federal Regulations, 2014 CFR
2014-07-01
... serve the purpose for which it is built. (3) Gas sampling records 75.336(e)(2) 1 year. (4) Record of... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Seals records. 75.339 Section 75.339 Mineral.... Table—§ 75.339(a) Seal Recordkeeping Requirements Record Section reference Retention time (1) Approved...
Code of Federal Regulations, 2010 CFR
2010-04-01
... record keeping functions; exercise of control over and hence responsibility and accountability for... proper and necessary uses even if any such uses occur infrequently. (h) Statistical record. A record in a system of records maintained for statistical research or reporting purposes only and not used in whole or...
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 1 2012-10-01 2012-10-01 false Records. 3.406 Section 3... PRACTICES AND PERSONAL CONFLICTS OF INTEREST Contingent Fees 3.406 Records. For enforcement purposes... all other pertinent data, including a record of actions taken. Contracting offices shall not retire or...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 1 2011-10-01 2011-10-01 false Records. 3.406 Section 3... PRACTICES AND PERSONAL CONFLICTS OF INTEREST Contingent Fees 3.406 Records. For enforcement purposes... all other pertinent data, including a record of actions taken. Contracting offices shall not retire or...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Records. 3.406 Section 3... PRACTICES AND PERSONAL CONFLICTS OF INTEREST Contingent Fees 3.406 Records. For enforcement purposes... all other pertinent data, including a record of actions taken. Contracting offices shall not retire or...
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 1 2014-10-01 2014-10-01 false Records. 3.406 Section 3... PRACTICES AND PERSONAL CONFLICTS OF INTEREST Contingent Fees 3.406 Records. For enforcement purposes... all other pertinent data, including a record of actions taken. Contracting offices shall not retire or...
Towards the mechanical characterization of abdominal wall by inverse analysis.
Simón-Allué, R; Calvo, B; Oberai, A A; Barbone, P E
2017-02-01
The aim of this study is to characterize the passive mechanical behaviour of abdominal wall in vivo in an animal model using only external cameras and numerical analysis. The main objective lies in defining a methodology that provides in vivo information of a specific patient without altering mechanical properties. It is demonstrated in the mechanical study of abdomen for hernia purposes. Mechanical tests consisted on pneumoperitoneum tests performed on New Zealand rabbits, where inner pressure was varied from 0mmHg to 12mmHg. Changes in the external abdominal surface were recorded and several points were tracked. Based on their coordinates we reconstructed a 3D finite element model of the abdominal wall, considering an incompressible hyperelastic material model defined by two parameters. The spatial distributions of these parameters (shear modulus and non linear parameter) were calculated by inverse analysis, using two different types of regularization: Total Variation Diminishing (TVD) and Tikhonov (H 1 ). After solving the inverse problem, the distribution of the material parameters were obtained along the abdominal surface. Accuracy of the results was evaluated for the last level of pressure. Results revealed a higher value of the shear modulus in a wide stripe along the craneo-caudal direction, associated with the presence of linea alba in conjunction with fascias and rectus abdominis. Non linear parameter distribution was smoother and the location of higher values varied with the regularization type. Both regularizations proved to yield in an accurate predicted displacement field, but H 1 obtained a smoother material parameter distribution while TVD included some discontinuities. The methodology here presented was able to characterize in vivo the passive non linear mechanical response of the abdominal wall. Copyright © 2016 Elsevier Ltd. All rights reserved.
31 CFR 1.5 - Specific requests for other records.
Code of Federal Regulations, 2011 CFR
2011-07-01
... threat to the life or physical safety of an individual. The requester shall fully explain the... information for the purpose of creating a record or records that do not exist. (h) Initial determination—(1...
Li, Yongping; Lao, Jie; Zhao, Xin; Tian, Dong; Zhu, Yi; Wei, Xiaochun
2014-01-01
The distance between the two electrode tips can greatly influence the parameters used for recording compound nerve action potentials. To investigate the optimal parameters for these recordings in the rat median nerve, we dissociated the nerve using different methods and compound nerve action potentials were orthodromically or antidromically recorded with different electrode spacings. Compound nerve action potentials could be consistently recorded using a method in which the middle part of the median nerve was intact, with both ends dissociated from the surrounding fascia and a ground wire inserted into the muscle close to the intact part. When the distance between two stimulating electrode tips was increased, the threshold and supramaximal stimulating intensity of compound nerve action potentials were gradually decreased, but the amplitude was not changed significantly. When the distance between two recording electrode tips was increased, the amplitude was gradually increased, but the threshold and supramaximal stimulating intensity exhibited no significant change. Different distances between recording and stimulating sites did not produce significant effects on the aforementioned parameters. A distance of 5 mm between recording and stimulating electrodes and a distance of 10 mm between recording and stimulating sites were found to be optimal for compound nerve action potential recording in the rat median nerve. In addition, the orthodromic compound action potential, with a biphasic waveform that was more stable and displayed less interference (however also required a higher threshold and higher supramaximal stimulus), was found to be superior to the antidromic compound action potential. PMID:25206798
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-05
...; Information Collection; Examination of Records by Comptroller General and Contract Audit AGENCIES: Department... examination of records by comptroller general and contract audit. Public comments are particularly invited on... e-mail [email protected] . SUPPLEMENTARY INFORMATION: A. Purpose The Audit and Records...
Code of Federal Regulations, 2013 CFR
2013-07-01
... you wish to film, photograph, or videotape for news purposes at a Presidential library or at a regional records services facility, you must contact the director of the library (see 36 CFR 1253.3 for... in 36 CFR part 1254 for permission to film archival records and donated materials for research...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Post, Wilfred M; King, Anthony Wayne; Dragoni, Danilo
Many parameters in terrestrial biogeochemical models are inherently uncertain, leading to uncertainty in predictions of key carbon cycle variables. At observation sites, this uncertainty can be quantified by applying model-data fusion techniques to estimate model parameters using eddy covariance observations and associated biometric data sets as constraints. Uncertainty is reduced as data records become longer and different types of observations are added. We estimate parametric and associated predictive uncertainty at the Morgan Monroe State Forest in Indiana, USA. Parameters in the Local Terrestrial Ecosystem Carbon (LoTEC) are estimated using both synthetic and actual constraints. These model parameters and uncertainties aremore » then used to make predictions of carbon flux for up to 20 years. We find a strong dependence of both parametric and prediction uncertainty on the length of the data record used in the model-data fusion. In this model framework, this dependence is strongly reduced as the data record length increases beyond 5 years. If synthetic initial biomass pool constraints with realistic uncertainties are included in the model-data fusion, prediction uncertainty is reduced by more than 25% when constraining flux records are less than 3 years. If synthetic annual aboveground woody biomass increment constraints are also included, uncertainty is similarly reduced by an additional 25%. When actual observed eddy covariance data are used as constraints, there is still a strong dependence of parameter and prediction uncertainty on data record length, but the results are harder to interpret because of the inability of LoTEC to reproduce observed interannual variations and the confounding effects of model structural error.« less
Code of Federal Regulations, 2010 CFR
2010-07-01
... Which Construction is Commenced After June 20, 1996 Pt. 60, Subpt. Ec, Table 3 Table 3 to Subpart Ec of... Operating parameters to be monitored Minimum frequency Data measurement Data recording Control system Dry scrubber followed by fabric filter Wet scrubber Dry scrubber followed by fabric filter and wet scrubber...
Code of Federal Regulations, 2011 CFR
2011-07-01
..., Forests, and Public Property NATIONAL ARCHIVES AND RECORDS ADMINISTRATION JFK ASSASSINATION RECORDS... COLLECTION ACT OF 1992 (JFK ACT) § 1290.4 Types of materials included in scope of assassination record and... information includes, for purposes of interpreting and implementing the JFK Act: (a) Papers, maps, and other...
Code of Federal Regulations, 2013 CFR
2013-07-01
..., Forests, and Public Property NATIONAL ARCHIVES AND RECORDS ADMINISTRATION JFK ASSASSINATION RECORDS... COLLECTION ACT OF 1992 (JFK ACT) § 1290.4 Types of materials included in scope of assassination record and... information includes, for purposes of interpreting and implementing the JFK Act: (a) Papers, maps, and other...
Code of Federal Regulations, 2012 CFR
2012-07-01
..., Forests, and Public Property NATIONAL ARCHIVES AND RECORDS ADMINISTRATION JFK ASSASSINATION RECORDS... COLLECTION ACT OF 1992 (JFK ACT) § 1290.4 Types of materials included in scope of assassination record and... information includes, for purposes of interpreting and implementing the JFK Act: (a) Papers, maps, and other...
Code of Federal Regulations, 2014 CFR
2014-07-01
..., Forests, and Public Property NATIONAL ARCHIVES AND RECORDS ADMINISTRATION JFK ASSASSINATION RECORDS... COLLECTION ACT OF 1992 (JFK ACT) § 1290.4 Types of materials included in scope of assassination record and... information includes, for purposes of interpreting and implementing the JFK Act: (a) Papers, maps, and other...
Code of Federal Regulations, 2010 CFR
2010-07-01
..., Forests, and Public Property NATIONAL ARCHIVES AND RECORDS ADMINISTRATION JFK ASSASSINATION RECORDS... COLLECTION ACT OF 1992 (JFK ACT) § 1290.4 Types of materials included in scope of assassination record and... information includes, for purposes of interpreting and implementing the JFK Act: (a) Papers, maps, and other...
12 CFR 404.19 - Request for accounting of record disclosures.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 12 Banks and Banking 4 2010-01-01 2010-01-01 false Request for accounting of record disclosures... Access to Records Under the Privacy Act of 1974 § 404.19 Request for accounting of record disclosures. (a... maintain an accurate accounting of the date, nature, and purpose of each external disclosure of a record...
15 CFR 762.4 - Original records required.
Code of Federal Regulations, 2012 CFR
2012-01-01
... to rely on that record to meet the recordkeeping requirements of the EAR, that person must retain the... print out of the complete document is deemed to be an original record for purposes of this section. [61...
15 CFR 762.4 - Original records required.
Code of Federal Regulations, 2011 CFR
2011-01-01
... to rely on that record to meet the recordkeeping requirements of the EAR, that person must retain the... print out of the complete document is deemed to be an original record for purposes of this section. [61...
15 CFR 762.4 - Original records required.
Code of Federal Regulations, 2013 CFR
2013-01-01
... to rely on that record to meet the recordkeeping requirements of the EAR, that person must retain the... print out of the complete document is deemed to be an original record for purposes of this section. [61...
15 CFR 762.4 - Original records required.
Code of Federal Regulations, 2014 CFR
2014-01-01
... to rely on that record to meet the recordkeeping requirements of the EAR, that person must retain the... print out of the complete document is deemed to be an original record for purposes of this section. [61...
Construction records study : final report.
DOT National Transportation Integrated Search
1975-09-01
The purpose of this study was to determine the extent of change and revision necessary for efficient record keeping and to revise the record keeping process in the field, eliminating irrelevant entries. This study attempted to standardize field recor...
The ADA's practice parameters.
Ellek, Donalda M
2005-01-01
The ADA parameters of care have served the needs of practicing dentists for fifteen years. Their purpose is to describe a range of treatment options that dentists will want to consider, in combination with particular clinical conditions and patient preferences. These options have been developed based on available evidence and a consensus of professional judgment. The ADA has exercised concern that parameters not be used, out of the context of individual professional judgment, for policy purposes.
Kamendi, Harriet; Barthlow, Herbert; Lengel, David; Beaudoin, Marie‐Eve; Snow, Debra
2016-01-01
Background and Purpose While the molecular pathways of baclofen toxicity are understood, the relationships between baclofen‐mediated perturbation of individual target organs and systems involved in cardiovascular regulation are not clear. Our aim was to use an integrative approach to measure multiple cardiovascular‐relevant parameters [CV: mean arterial pressure (MAP), systolic BP, diastolic BP, pulse pressure, heart rate (HR); CNS: EEG; renal: chemistries and biomarkers of injury] in tandem with the pharmacokinetic properties of baclofen to better elucidate the site(s) of baclofen activity. Experimental Approach Han‐Wistar rats were administered vehicle or ascending doses of baclofen (3, 10 and 30 mg·kg−1, p.o.) at 4 h intervals and baclofen‐mediated changes in parameters recorded. A pharmacokinetic–pharmacodynamic model was then built by implementing an existing mathematical model of BP in rats. Key Results Final model fits resulted in reasonable parameter estimates and showed that the drug acts on multiple homeostatic processes. In addition, the models testing a single effect on HR, total peripheral resistance or stroke volume alone did not describe the data. A final population model was constructed describing the magnitude and direction of the changes in MAP and HR. Conclusions and Implications The systems pharmacology model developed fits baclofen‐mediated changes in MAP and HR well. The findings correlate with known mechanisms of baclofen pharmacology and suggest that similar models using limited parameter sets may be useful to predict the cardiovascular effects of other pharmacologically active substances. PMID:27448216
NASA Astrophysics Data System (ADS)
Meguellati, F.; Graner, G.; Burczyk, K.; Bürger, H.
1997-10-01
High-resolution infrared spectra of monoisotopic samples of F35Cl18O3and F37Cl18O3have been recorded with the purpose of analyzing the ν3fundamental at 535 cm-1. However, this band could not be observed whereas it had been seen and studied earlier in F35Cl16O3. To determine the parameters of thev3= 1 state, indirect methods were used. Hot bands νn+ ν3- ν3(n= 1 or 2) were first analyzed and their LSCD (Lower State Combination Differences) yielded rotational parameters of ν3. Then, with the help of ν1+ ν3, all rovibrational parameters of ν3were obtained. Similar methods were applied to spectra of F35Cl16O3and F37Cl16O3to prove that the parameters of ν3obtained in this fashion are identical to those determined directly for these isotopomers and are even more comprehensive. It is shown that the different character of ν3in the two18O and in the two16O isotopomers is due to the fact that the former are much closer to a spherical top molecule ((A0- B0)/A0= 0.015). This is not only reflected in intensities different by two orders of magnitude but also in the very different values of α3Bin these two pairs.
Slanina, Tomáš; Miškeje, Michal; Tirpák, Filip; Błaszczyk, Martyna; Formicki, Grzegorz; Massányi, Peter
2018-03-01
The purpose of this study was to evaluate the impact of caffeine on turkey spermatozoa during in vitro incubation. Experimental samples were prepared by diluting the raw semen with nine different concentrations of caffeine - from 0.078125 mg/mL to 10 mg/mL. The individual motility parameters were evaluated by the Computer Assisted Semen Analyser (CASA) system, and the viability of spermatozoa was evaluated using eosin-nigrosin staining. Selected parameters were recorded at six time periods: 0, 1, 2, 3, 4 and 5 h at 5 °C and 41 °C. A significantly higher motility and progressive motility of spermatozoa (P < 0.01 and P < 0.001, respectively) was detected in the samples containing caffeine ranging from 0.15625 to 7.5 mg/mL as compared to the control sample at 5 °C. At an incubation temperature of 41 °C the positive effect of caffeine on motility parameters was observed only at the beginning of incubation (at times 0 and 1). The tested caffeine concentrations showed no significant effect on the viability of turkey spermatozoa at any time period of incubation. A higher percentage of dead spermatozoa was observed for incubation at 41 °C (from 5.96% to 11.1%) in comparison to 5 °C (from 1.62% to 5.79%). The results suggest that caffeine can be used as a suitable component of turkey semen extenders and has the potential to improve fertility.
75 FR 54966 - Privacy Act of 1974: Computer Matching Program
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-09
... agencies for purposes of verification of income for determining eligibility for benefits. 38 U.S.C. 1710(a... income verification process. The VA records involved in the match are ``Enrollment and Eligibility Records--VA'' (147VA16). The SSA records are from the Earnings Recording and Self- Employment Income...
78 FR 21713 - Privacy Act of 1974: Computer Matching Program
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-11
... income information from other agencies for purposes of verification of income for determining eligibility... data needed for the income verification process. The VA records involved in the match are ``Enrollment and Eligibility Records--VA'' (147VA16). The SSA records are from the Earnings Recording and Self...
36 CFR 1270.50 - Consultation with law enforcement agencies.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Consultation with law enforcement agencies. 1270.50 Section 1270.50 Parks, Forests, and Public Property NATIONAL ARCHIVES AND RECORDS ADMINISTRATION PRESIDENTIAL RECORDS PRESIDENTIAL RECORDS Presidential Records Compiled for Law Enforcement Purposes § 1270.50 Consultation with...
29 CFR 2702.5 - Fees applicable-categories of requesters.
Code of Federal Regulations, 2013 CFR
2013-07-01
... searching for, reviewing for release, and duplicating the records sought. (b) When records are being requested by educational or noncommercial scientific institutions whose purpose is scholarly or scientific... records sought, but no charge will be made for the first 100 paper pages reproduced. (c) When records are...
29 CFR 2702.5 - Fees applicable-categories of requesters.
Code of Federal Regulations, 2012 CFR
2012-07-01
... searching for, reviewing for release, and duplicating the records sought. (b) When records are being requested by educational or noncommercial scientific institutions whose purpose is scholarly or scientific... records sought, but no charge will be made for the first 100 paper pages reproduced. (c) When records are...
29 CFR 2702.5 - Fees applicable-categories of requesters.
Code of Federal Regulations, 2014 CFR
2014-07-01
... searching for, reviewing for release, and duplicating the records sought. (b) When records are being requested by educational or noncommercial scientific institutions whose purpose is scholarly or scientific... records sought, but no charge will be made for the first 100 paper pages reproduced. (c) When records are...
29 CFR 2702.5 - Fees applicable-categories of requesters.
Code of Federal Regulations, 2011 CFR
2011-07-01
... searching for, reviewing for release, and duplicating the records sought. (b) When records are being requested by educational or noncommercial scientific institutions whose purpose is scholarly or scientific... records sought, but no charge will be made for the first 100 paper pages reproduced. (c) When records are...
Banar, Müfide; Ozkan, Aysun; Kürkçüoğlu, Mine
2006-10-01
The aim of this study is to evaluate extensively the characterization and identification of major pollutant parameters by paying attention to the organic chemical pollution for unregulated dumping site leachate in Eskişehir/Turkey. The study that is first and only one research has been very important data related with before new sanitary landfill site in Eskişehir city. For this purpose, in this study leachate samples were collected in-situ at monthly interval for a period of 8 months. Firstly, thirty three physicochemical parameters were monitored. Secondly, SPME technique was used for identification of organic pollutants. Meteorological data were also recorded for the same sampling period to correlate meteorological data and physicochemical parameters. Mean values are used in the correlation analysis. Correlation is shown only for the relationship between air temperature and NO(3) (-). No correlation has been found between rain and leachate quality parameters since the amount of rain was very low during the sampling period. However, analysis results were generally decreased in winter season when each parameter and each sampling point are examined separately. According to correlation between every parameter, especially solid content and dissolved oxygen concentration of leachate is affecting to other parameters. Also, sodium and potassium are changing proportionally with same parameters (suspended solids, fixed solids, dissolved oxygen) and high correlation between chloride and heavy metal concentration is showing. The results were statistically evaluated by use of SPSS 10.0 program. Second part of the study, the leachate was extracted by Solid Phase Microextraction (SPME) technique and then analyzed. Of the methodologies tested in this study, the best one selected was based on 100 micro m polydimethylsiloxane coated fiber (PDMS), headspace with heating (Delta HS) sampling mode and an extraction time of 15 min. at a temperature of 50 degrees C. Thirty three organic compounds in leachate were identified by GC/MS.
14 CFR 125.228 - Flight data recorders: filtered data.
Code of Federal Regulations, 2014 CFR
2014-01-01
... when an original sensor signal has been changed in any way, other than changes necessary to: (1... sensor. (b) An original sensor signal for any flight recorder parameter required to be recorded under... original sensor signal value can be reconstructed from the recorded data. This demonstration requires that...
14 CFR 135.156 - Flight data recorders: filtered data.
Code of Federal Regulations, 2013 CFR
2013-01-01
... when an original sensor signal has been changed in any way, other than changes necessary to: (1... sensor. (b) An original sensor signal for any flight recorder parameter required to be recorded under... original sensor signal value can be reconstructed from the recorded data. This demonstration requires that...
14 CFR 125.228 - Flight data recorders: filtered data.
Code of Federal Regulations, 2012 CFR
2012-01-01
... when an original sensor signal has been changed in any way, other than changes necessary to: (1... sensor. (b) An original sensor signal for any flight recorder parameter required to be recorded under... original sensor signal value can be reconstructed from the recorded data. This demonstration requires that...
14 CFR 135.156 - Flight data recorders: filtered data.
Code of Federal Regulations, 2012 CFR
2012-01-01
... when an original sensor signal has been changed in any way, other than changes necessary to: (1... sensor. (b) An original sensor signal for any flight recorder parameter required to be recorded under... original sensor signal value can be reconstructed from the recorded data. This demonstration requires that...
14 CFR 135.156 - Flight data recorders: filtered data.
Code of Federal Regulations, 2014 CFR
2014-01-01
... when an original sensor signal has been changed in any way, other than changes necessary to: (1... sensor. (b) An original sensor signal for any flight recorder parameter required to be recorded under... original sensor signal value can be reconstructed from the recorded data. This demonstration requires that...
14 CFR 125.228 - Flight data recorders: filtered data.
Code of Federal Regulations, 2013 CFR
2013-01-01
... when an original sensor signal has been changed in any way, other than changes necessary to: (1... sensor. (b) An original sensor signal for any flight recorder parameter required to be recorded under... original sensor signal value can be reconstructed from the recorded data. This demonstration requires that...
Optical studies in the holographic ground station
NASA Technical Reports Server (NTRS)
Workman, Gary L.
1991-01-01
The Holographic Group System (HGS) Facility in rooms 22 & 123, Building 4708 has been developed to provide for ground based research in determining pre-flight parameters and analyzing the results from space experiments. The University of Alabama, Huntsville (UAH) has researched the analysis aspects of the HGS and reports their findings here. Some of the results presented here also occur in the Facility Operating Procedure (FOP), which contains instructions for power up, operation, and powerdown of the Fluid Experiment System (FES) Holographic Ground System (HGS) Test Facility for the purpose of optically recording fluid and/or crystal behavior in a test article during ground based testing through the construction of holograms and recording of videotape. The alignment of the optical bench components, holographic reconstruction and and microscopy alignment sections were also included in the document for continuity even though they are not used until after optical recording of the test article) setup of support subsystems and the Automated Holography System (AHS) computer. The HGS provides optical recording and monitoring during GCEL runs or development testing of potential FES flight hardware or software. This recording/monitoring can be via 70mm holographic film, standard videotape, or digitized images on computer disk. All optical bench functions necessary to construct holograms will be under the control of the AHS personal computer (PC). These include type of exposure, time intervals between exposures, exposure length, film frame identification, film advancement, film platen evacuation and repressurization, light source diffuser introduction, and control of realtime video monitoring. The completed sequence of hologram types (single exposure, diffuse double exposure, etc.) and their time of occurrence can be displayed, printed, or stored on floppy disk posttest for the user.
Manual editing of automatically recorded data in an anesthesia information management system.
Wax, David B; Beilin, Yaakov; Hossain, Sabera; Lin, Hung-Mo; Reich, David L
2008-11-01
Anesthesia information management systems allow automatic recording of physiologic and anesthetic data. The authors investigated the prevalence of such data modification in an academic medical center. The authors queried their anesthesia information management system database of anesthetics performed in 2006 and tabulated the counts of data points for automatically recorded physiologic and anesthetic parameters as well as the subset of those data that were manually invalidated by clinicians (both with and without alternate values manually appended). Patient, practitioner, data source, and timing characteristics of recorded values were also extracted to determine their associations with editing of various parameters in the anesthesia information management system record. A total of 29,491 cases were analyzed, 19% of which had one or more data points manually invalidated. Among 58 attending anesthesiologists, each invalidated data in a median of 7% of their cases when working as a sole practitioner. A minority of invalidated values were manually appended with alternate values. Pulse rate, blood pressure, and pulse oximetry were the most commonly invalidated parameters. Data invalidation usually resulted in a decrease in parameter variance. Factors independently associated with invalidation included extreme physiologic values, American Society of Anesthesiologists physical status classification, emergency status, timing (phase of the procedure/anesthetic), presence of an intraarterial catheter, resident or certified registered nurse anesthetist involvement, and procedure duration. Editing of physiologic data automatically recorded in an anesthesia information management system is a common practice and results in decreased variability of intraoperative data. Further investigation may clarify the reasons for and consequences of this behavior.
Code of Federal Regulations, 2011 CFR
2011-07-01
... to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR RECORDING AND REPORTING OCCUPATIONAL INJURIES AND ILLNESSES Purpose § 1904.0 Purpose. The purpose of this rule (Part 1904... employer or employee was at fault, that an OSHA rule has been violated, or that the employee is eligible...
Code of Federal Regulations, 2010 CFR
2010-07-01
... to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR RECORDING AND REPORTING OCCUPATIONAL INJURIES AND ILLNESSES Purpose § 1904.0 Purpose. The purpose of this rule (Part 1904... employer or employee was at fault, that an OSHA rule has been violated, or that the employee is eligible...
20 CFR 401.155 - Law enforcement purposes.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false Law enforcement purposes. 401.155 Section 401... INFORMATION Disclosure of Official Records and Information § 401.155 Law enforcement purposes. (a) General. The Privacy Act allows us to disclose information for law enforcement purposes under certain...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 32 National Defense 2 2010-07-01 2010-07-01 false Form Letter-Conditions Governing Access to Official Records for Historical Research Purposes E Appendix E to Part 197 National Defense Department of... THE FILES OF THE OFFICE OF THE SECRETARY OF DEFENSE (OSD) Pt. 197, App. E Appendix E to Part 197—Form...
Hanada, Takashi; Katsuta, Shoichi; Yorozu, Atsunori; Maruyama, Koichi
2009-01-01
When using a HDR remote afterloading brachytherapy unit, results of treatment can be greatly influenced by both source position and treatment time. The purpose of this study is to obtain information on the source of the HDR remote afterloading unit, such as its position and time structure, with the use of a simple system consisting of a plastic scintillator block and a charge‐coupled device (CCD) camera. The CCD camera was used for recording images of scintillation luminescence at a fixed rate of 30 frames per second in real time. The source position and time structure were obtained by analyzing the recorded images. For a preset source‐step‐interval of 5 mm, the measured value of the source position was 5.0±1.0mm, with a pixel resolution of 0.07 mm in the recorded images. For a preset transit time of 30 s, the measured value was 30.0±0.6 s, when the time resolution of the CCD camera was 1/30 s. This system enabled us to obtain the source dwell time and movement time. Therefore, parameters such as I192r source position, transit time, dwell time, and movement time at each dwell position can be determined quantitatively using this plastic scintillator‐CCD camera system. PACS number: 87.53.Jw
Assessing performance of feedlot operations using epidemiology.
Corbin, Marilyn J; Griffin, Dee
2006-03-01
The progressive feedlot veterinarian must be well versed not only in individual production animal medicine, but also in population-based medicine. Feedlot health programs must be goal oriented, and evaluation of these goals is accomplished through diligent use of record systems and analytic evaluation of these record systems. Basic feedlot monitoring parameters include health and economic parameters in addition to the use of bench marking parameters between and among feed yards. When these parameters have significant changes, steps should be initiated to begin field investigations. Feedlot epidemiology uses several novel applications such as partial budgeting, risk assessment, and packing plant audits to provide scientifically sound and economically feasible solutions for the feeding industry.
Validation of computer simulation training for esophagogastroduodenoscopy: Pilot study.
Sedlack, Robert E
2007-08-01
Little is known regarding the value of esophagogastroduodenoscopy (EGD) simulators in education. The purpose of the present paper was to validate the use of computer simulation in novice EGD training. In phase 1, expert endoscopists evaluated various aspects of simulation fidelity as compared to live endoscopy. Additionally, computer-recorded performance metrics were assessed by comparing the recorded scores from users of three different experience levels. In phase 2, the transfer of simulation-acquired skills to the clinical setting was assessed in a two-group, randomized pilot study. The setting was a large gastroenterology (GI) Fellowship training program; in phase 1, 21 subjects (seven expert, intermediate and novice endoscopist), made up the three experience groups. In phase 2, eight novice GI fellows were involved in the two-group, randomized portion of the study examining the transfer of simulation skills to the clinical setting. During the initial validation phase, each of the 21 subjects completed two standardized EDG scenarios on a computer simulator and their performance scores were recorded for seven parameters. Following this, staff participants completed a questionnaire evaluating various aspects of the simulator's fidelity. Finally, four novice GI fellows were randomly assigned to receive 6 h of simulator-augmented training (SAT group) in EGD prior to beginning 1 month of patient-based EGD training. The remaining fellows experienced 1 month of patient-based training alone (PBT group). Results of the seven measured performance parameters were compared between three groups of varying experience using a Wilcoxon ranked sum test. The staffs' simulator fidelity survey used a 7-point Likert scale (1, very unrealistic; 4, neutral; 7, very realistic) for each of the parameters examined. During the second phase of this study, supervising staff rated both SAT and PBT fellows' patient-based performance daily. Scoring in each skill was completed using a 7-point Likert scale (1, strongly disagree; 4, neutral; 7, strongly agree). Median scores were compared between groups using the Wilcoxon ranked sum test. Staff evaluations of fidelity found that only two of the parameters examined (anatomy and scope maneuverability) had a significant degree of realism. The remaining areas were felt to be limited in their fidelity. Of the computer-recorded performance scores, only the novice group could be reliably identified from the other two experience groups. In the clinical application phase, the median Patient Discomfort ratings were superior in the PBT group (6; interquartile range [IQR], 5-6) as compared to the SAT group (5; IQR, 4-6; P = 0.015). PBT fellows' ratings were also superior in Sedation, Patient Discomfort, Independence and Competence during various phases of the evaluation. At no point were SAT fellows rated higher than the PBT group in any of the parameters examined. This EGD simulator has limitations to the degree of fidelity and can differentiate only novice endoscopists from other levels of experience. Finally, skills learned during EGD simulation training do not appear to translate well into patient-based endoscopy skills. These findings suggest against a key element of validity for the use of this computer simulator in novice EGD training.
SU-E-T-11: A Cloud Based CT and LINAC QA Data Management System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wiersma, R; Grelewicz, Z; Belcher, A
Purpose: The current status quo of QA data management consists of a mixture of paper-based forms and spreadsheets for recording the results of daily, monthly, and yearly QA tests for both CT scanners and LINACs. Unfortunately, such systems suffer from a host of problems as, (1) records can be easily lost or destroyed, (2) data is difficult to access — one must physically hunt down records, (3) poor or no means of historical data analysis, and (4) no remote monitoring of machine performance off-site. To address these issues, a cloud based QA data management system was developed and implemented. Methods:more » A responsive tablet interface that optimizes clinic workflow with an easy-to-navigate interface accessible from any web browser was implemented in HTML/javascript/CSS to allow user mobility when entering QA data. Automated image QA was performed using a phantom QA kit developed in Python that is applicable to any phantom and is currently being used with the Gammex ACR, Las Vegas, Leeds, and Catphan phantoms for performing automated CT, MV, kV, and CBCT QAs, respectively. A Python based resource management system was used to distribute and manage intensive CPU tasks such as QA phantom image analysis or LaTeX-to-PDF QA report generation to independent process threads or different servers such that website performance is not affected. Results: To date the cloud QA system has performed approximately 185 QA procedures. Approximately 200 QA parameters are being actively tracked by the system on a monthly basis. Electronic access to historical QA parameter information was successful in proactively identifying a Linac CBCT scanner’s performance degradation. Conclusion: A fully comprehensive cloud based QA data management system was successfully implemented for the first time. Potential machine performance issues were proactively identified that would have been otherwise missed by a paper or spreadsheet based QA system.« less
Field spectrometer (S191H) preprocessor tape quality test program design document
NASA Technical Reports Server (NTRS)
Campbell, H. M.
1976-01-01
Program QA191H performs quality assurance tests on field spectrometer data recorded on 9-track magnetic tape. The quality testing involves the comparison of key housekeeping and data parameters with historic and predetermined tolerance limits. Samples of key parameters are processed during the calibration period and wavelength cal period, and the results are printed out and recorded on an historical file tape.
Capesius, Joseph P.; Sullivan, Joseph R.; O'Neill, Gregory B.; Williams, Cory A.
2005-01-01
Accurate ice-affected streamflow records are difficult to obtain for several reasons, which makes the management of instream-flow water rights in the wintertime a challenging endeavor. This report documents a method to improve ice-affected streamflow records for two gaging stations in Colorado. In January and February 2002, the U.S. Geological Survey, in cooperation with the Colorado Water Conservation Board, conducted an experiment using a sodium chloride tracer to measure streamflow under ice cover by the tracer-dilution discharge method. The purpose of this study was to determine the feasibility of obtaining accurate ice-affected streamflow records by using a sodium chloride tracer that was injected into the stream. The tracer was injected at two gaging stations once per day for approximately 20 minutes for 25 days. Multiple-parameter water-quality sensors at the two gaging stations monitored background and peak chloride concentrations. These data were used to determine discharge at each site. A comparison of the current-meter streamflow record to the tracer-dilution streamflow record shows different levels of accuracy and precision of the tracer-dilution streamflow record at the two sites. At the lower elevation and warmer site, Brandon Ditch near Whitewater, the tracer-dilution method overestimated flow by an average of 14 percent, but this average is strongly biased by outliers. At the higher elevation and colder site, Keystone Gulch near Dillon, the tracer-dilution method experienced problems with the tracer solution partially freezing in the injection line. The partial freezing of the tracer contributed to the tracer-dilution method underestimating flow by 52 percent at Keystone Gulch. In addition, a tracer-pump-reliability test was conducted to test how accurately the tracer pumps can discharge the tracer solution in conditions similar to those used at the gaging stations. Although the pumps were reliable and consistent throughout the 25-day study period, the pumps underdischarged the tracer by 5.8-15.9 percent as compared to the initial pumping rate setting, which may explain some of the error in the tracer-dilution streamflow record as compared to current-meter streamflow record.
Freundt, Miriam; Lunz, Dirk; Philipp, Alois; Panholzer, Bernd; Lubnow, Matthias; Friedrich, Christine; Rupprecht, Leopold; Hirt, Stephan; Haneya, Assad
2017-01-01
Veno-arterial extracorporeal life support (ECLS) is an established method to stabilize acute circulatory failure. Parameters and data on when to ideally wean circulatory support are limited. Bilirubin is a marker of end-organ damage. Therefore, the purpose of this large study was to evaluate the impact of dynamic changes of elevated bilirubin levels on survival in patients on ECLS. We reviewed 502 consecutive cases of ECLS from 2007 to 2015. Bilirubin levels were recorded before implantation and until six days after explantation. Dynamic bilirubin changes, and hemodynamic and laboratory outcome parameters were compared in survivors and nonsurvivors. Reason for ECLS implantation was cardiac arrest with ongoing resuscitation in 230 (45.8%), low cardiac output in 174 (34.7%) and inability to wean off cardiopulmonary bypass in 98 (19.5%) patients. 307 (61.2%) patients were weaned off ECLS, however, 206 (41.0%) survived. Mean duration of ECLS was 3 (2-6) days, and survivors received significantly longer ECLS (5 vs 3 days, p < 0.001). Survivors had significantly lower baseline bilirubin levels (p = 0.003). Bilirubin started to rise from day 2 in all patients. In survivors, bilirubin levels had trended down on the day of ECLS explantation and stayed at an acceptable level. However, in weaned patients who did not survive and patients who died on ECLS bilirubin levels continued to rise during the recorded period. ECLS support improves survival in patients with acute circulatory failure. Down trending bilirubin levels on veno-arterial ECLS indicate improved chances of successful weaning and survival in hemodynamically stable patients.
Makki, Elsamawal Khalil
2014-01-01
Little quantitative information is available on animal power in the Nile Valley in Sudan, despite that it is being used in the area for centuries and playing an important role in agriculture in the present day. A survey was conducted to assess draught oxen management and its association with field capacity and efficiency at the farm level and to identify potential areas for intervention. A sample of 50 farmers was selected for this purpose using the systematic random sampling technique. The main management parameters discussed were animal health, feeding, housing, work strategy and care for yoke and plough. The results showed that most of the farmers poorly manage their animals, and this was reflected in low working speeds and field efficiencies. The main dimensions of poor management were in veterinary care (78 % did not take their animals to the veterinary centre), feeding (66 % feed their animals shortly before work) and care for yoke (80 % did not follow daily care measures for their yokes) and plough (74 % did not follow plough care measure before and after work). Low working speeds (0.90–2.0 km/h) were recorded by the majority of the farmers (64 %). The majority of the farmers (70 %) recorded field capacities between 0.06 and 0.10 ha/h, while all of them worked at high field efficiencies of >86 %. The only parameter that significantly affected field capacity was the yoke-related wounds (p = 0.019). Extension advice and capacity building in husbandry and working practices were identified as principal entry points for intervention.
40 CFR 63.5190 - What records must I maintain?
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 12 2011-07-01 2009-07-01 true What records must I maintain? 63.5190... What records must I maintain? (a) You must maintain the records specified in paragraphs (a) and (b) of...) Volatile matter and solids content data for the purpose of demonstrating compliance in accordance with § 63...
76 FR 4880 - Privacy Act of 1974; Systems of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-27
... (December 5, 2006); (12) MSPB/GOVT-1: Appeals and Case Records, 67 FR 70254 (November 21, 2002); (13) OGE... case EAC determines that the disclosure is compatible with the purpose for which the records were... 300, Washington, DC 20005. In the case where an individual believes EAC maintains records pertaining...
36 CFR 1012.7 - Can I get an authenticated copy of a Presidio Trust record?
Code of Federal Regulations, 2010 CFR
2010-07-01
... copy of a Presidio Trust record, for purposes of admissibility under Federal, State or Tribal law. We... copy of a Presidio Trust record? 1012.7 Section 1012.7 Parks, Forests, and Public Property PRESIDIO TRUST LEGAL PROCESS: TESTIMONY BY EMPLOYEES AND PRODUCTION OF RECORDS Responsibilities of Requesters...
12 CFR 914.3 - Access to books and records.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 12 Banks and Banking 7 2010-01-01 2010-01-01 false Access to books and records. 914.3 Section 914... BANKS DATA AVAILABILITY AND REPORTING § 914.3 Access to books and records. Each Bank shall make its books and records readily available for inspection and other supervisory purposes within a reasonable...
12 CFR 914.3 - Access to books and records.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 12 Banks and Banking 7 2011-01-01 2011-01-01 false Access to books and records. 914.3 Section 914... BANKS DATA AVAILABILITY AND REPORTING § 914.3 Access to books and records. Each Bank shall make its books and records readily available for inspection and other supervisory purposes within a reasonable...
22 CFR 215.1 - Purpose and scope.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 22 Foreign Relations 1 2011-04-01 2011-04-01 false Purpose and scope. 215.1 Section 215.1 Foreign... Purpose and scope. (a) It is the purpose and objective of the International Development Cooperation Agency... procedures by which an individual may obtain notification of the existence of Agency records pertaining to...
22 CFR 215.1 - Purpose and scope.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Purpose and scope. 215.1 Section 215.1 Foreign... Purpose and scope. (a) It is the purpose and objective of the International Development Cooperation Agency... procedures by which an individual may obtain notification of the existence of Agency records pertaining to...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Guang-Pei, E-mail: gpchen@mcw.edu; Ahunbay, Ergun; Li, X. Allen
Purpose: To develop an integrated quality assurance (QA) software tool for online replanning capable of efficiently and automatically checking radiation treatment (RT) planning parameters and gross plan quality, verifying treatment plan data transfer from treatment planning system (TPS) to record and verify (R&V) system, performing a secondary monitor unit (MU) calculation with or without a presence of a magnetic field from MR-Linac, and validating the delivery record consistency with the plan. Methods: The software tool, named ArtQA, was developed to obtain and compare plan and treatment parameters from both the TPS and the R&V system database. The TPS data aremore » accessed via direct file reading and the R&V data are retrieved via open database connectivity and structured query language. Plan quality is evaluated with both the logical consistency of planning parameters and the achieved dose–volume histograms. Beams in between the TPS and R&V system are matched based on geometry configurations. To consider the effect of a 1.5 T transverse magnetic field from MR-Linac in the secondary MU calculation, a method based on modified Clarkson integration algorithm was developed and tested for a series of clinical situations. Results: ArtQA has been used in their clinic and can quickly detect inconsistencies and deviations in the entire RT planning process. With the use of the ArtQA tool, the efficiency for plan check including plan quality, data transfer, and delivery check can be improved by at least 60%. The newly developed independent MU calculation tool for MR-Linac reduces the difference between the plan and calculated MUs by 10%. Conclusions: The software tool ArtQA can be used to perform a comprehensive QA check from planning to delivery with conventional Linac or MR-Linac and is an essential tool for online replanning where the QA check needs to be performed rapidly.« less
Application of "FLUOR-P" device for analysis of the space flight effects on the intracellular level.
NASA Astrophysics Data System (ADS)
Grigorieva, Olga; Rudimov, Evgeny; Buravkova, Ludmila; Galchuk, Sergey
The mechanisms of cellular gravisensitivity still remain unclear despite the intensive research in the hypogravity effects on cellular function. In most cell culture experiments on unmanned vehicles "Bion" and "Photon", as well as on the ISS only allow post-flight analysis of biological material, including fixed cells is provided. The dynamic evaluation cellular parameters over a prolonged period of time is not possible. Thus, a promising direction is the development of equipment for onboard autonomous experiments. For this purpose, the SSC RF IBMP RAS has developed "FLUOR-P" device for measurement and recording of the dynamic differential fluorescent signal from nano- and microsized objects of organic and inorganic nature (human and animal cells, unicellular algae, bacteria, cellular organelles suspension) in hermetically sealed cuvettes. Besides, the device allows to record the main physical factors affecting the analyzed object (temperature and gravity loads: position in space, any vector acceleration, shock) in sync with the main measurements. The device is designed to perform long-term programmable autonomous experiments in space flight on biological satellites. The device software of allows to carry out complex experiments using cell. Permanent registration of data on built-in flash will give the opportunity to analyze the dynamics of the estimated parameters. FLUOR-P is designed as a monobloc (5.5 kg weight), 8 functional blocks are located in the inner space of the device. Each registration unit of the FLUOR-P has two channels of fluorescence intensity and excitation light source with the wavelength range from 300 nm to 700 nm. During biosatellite "Photon" flight is supposed to conduct a full analysis of the most important intracellular parameters (mitochondria activity and intracellular pH) dynamics under space flight factors and to assess the possible contribution of temperature on the effects of microgravity. Work is supported by Roskosmos and the Russian Academy of Sciences.
Effects of acute brainstem compression on auditory brainstem response in the guinea pig.
Tu, T Y; Yu, L H; Chiu, J H; Shu, C H; Shiao, A S; Lien, C F
1998-11-01
The purpose of this study was to establish the norm for parameters of auditory brainstem response (ABR) in the guinea pig and to investigate if acute brainstem compression results in significant changes to these parameters. Thirty-six guinea pigs with positive Preyer's reflex were anesthetized. A craniectomy was performed to remove the right occipital bone and the dura mater was opened to expose the brain, cerebellum and cerebellopontine angle (CPA). A small inflatable balloon was placed into the CPA precisely and slowly. ABR was recorded before incision of the skin as a baseline value, after placement and after inflation of the balloon with water at 0.1-ml intervals. Five stable peaks were recorded in 27 experimental animals. When the balloon was inflated with 0.1 ml water, the absolute latency (AL) of peaks IV and V and the interpeak latency (IPL) of peaks III and IV, and IV and V were prolonged. The amplitude ratios (AR) of peaks II, III, IV and V to peak I decreased. Inflation of the balloon with 0.2 ml of water caused further elongation of ALs of peaks IV and V and decreases in each AR. When the balloon volume increased to 0.3 ml, peak V became unrecognizable and peaks III and IV showed significant elongation of AL; peaks I and II did not show significant change in ALs. Further increase of the balloon volume to 0.4 ml resulted in disappearance of peaks III, IV and V; AL of peak II was also elongated. However, the amplitude and AL of peak I remained unchanged. Similar changes were observed in IPLs. This study establishes the norm of parameters of ABR in guinea pigs and demonstrates that acute brainstem compression causes elongation of ALs and IPLs of peaks II, III, IV and V. This suggests that peaks II, III, IV and V come from the brainstem and that peak I is not generated from the brainstem in the guinea pig.
Resting and postexercise heart rate variability in professional handball players.
Kayacan, Yildirim; Yildiz, Sedat
2016-03-01
The aim of this study was to evaluate heart rate variability (HRV) in professional handball players during rest and following a 5 min mild jogging exercise. For that purpose, electrocardiogram (ECG) of male handball players (N.=12, mean age 25±3.95 years) and sedentary controls (N.=14, mean age 23.5±2.95 years) were recorded for 5 min at rest and just after 5 min of mild jogging. ECGs were recorded and following HRV parameters were calculated: time-domain variables such as heart rate (HR), average normal-to-normal RR intervals, standard deviation of normal-to-normal RR intervals, square root of the mean of the squares of differences between adjacent NN intervals, percentage of differences between adjacent NN intervals that are greater than 50 milliseconds (pNN50), and frequency-domain variables such as very low frequency, low (LF) and high frequency (HF) of the power and LF/HF ratio. Unpaired t-test was used to find out differences among groups while paired t-test was used for comparison of each group for pre- and postjogging HRV. Pearson correlations were carried out to find out the relationships between the parameters. Blood pressures were not different between handball players and sedentary controls but exercise increased systolic blood pressure (P<0.01). HR was increased with exercise (P<0.001) and was slower in handball players (P<0.01). QTc was increased with exercise (P<0.001) and was higher in handball players (P<0.001). Exercise decreased pNN50 values in both groups but LF/HF ratio increased only in sedentary subjects. In conclusion, results of the HRV parameters show that sympathovagal balance does not appear to change in handball players in response to a mild, short-time (5 min) jogging exercise. However, in sedentary subjects, either the sympathetic regulation of the autonomous nervous system increased or vagal withdrawal occurred.
Osawa, T; Kuchida, K; Hidaka, S; Kato, T
2008-01-01
In Japan, the degree of marbling in ribeye (M. longissimus thoracis) is evaluated in the beef meat grading process. However, other muscles (e.g., M. trapezius) are also important in determining the meat quality and carcass market prices. The purpose of this study was to estimate genetic parameters for M. longissimus thoracis (M-LONG) and M. trapezius (M-TRAP) of carcass cross section of Japanese Black steers by computer image analysis. The number of records of Japanese Black steers and the number of pedigree records were 2,925 and 10,889, respectively. Digital images of the carcass cross section were taken between the sixth and seventh ribs by photographing equipment. Muscle area (MA), fat area ratio (FAR), overall coarseness of marbling particles (OCM), and coarseness of maximum marbling particle (MMC) in M-LONG and M-TRAP were calculated by image analysis. Genetic parameters for these traits were estimated using the AIREMLF90 program with an animal model. Fixed effects that were included in the model were dates of arrival at the carcass market and slaughter age (mo), and random effects of fattening farms, additive genetic effects and residuals were included in the model. For M-LONG, heritability estimates (+/-SE) were 0.46 +/- 0.06, 0.59 +/- 0.06, 0.47 +/- 0.06, and 0.20 +/- 0.05 for MA, FAR, OCM, and MMC, respectively. Heritability estimates (+/-SE) in M-TRAP were 0.47 +/- 0.06, 0.57 +/- 0.07, 0.49 +/- 0.07, and 0.13 +/- 0.04 for the same traits. Genetic correlations between subcutaneous fat thickness and FAR for M-LONG and M-TRAP were negative (-0.21 and -0.19, respectively). Those correlations between M-LONG and M-TRAP were moderate to high for MA, FAR, OCM, and MMC (0.38, 0.52, 0.39, and 0.60, respectively). These results indicate that other muscles including M-LONG should be evaluated for more efficient genetic improvement.
NASA Astrophysics Data System (ADS)
Chen, X.; Abercrombie, R. E.; Pennington, C.
2017-12-01
Recorded seismic waveforms include contributions from earthquake source properties and propagation effects, leading to long-standing trade-off problems between site/path effects and source effects. With near-field recordings, the path effect is relatively small, so the trade-off problem can be simplified to between source and site effects (commonly referred as "kappa value"). This problem is especially significant for small earthquakes where the corner frequencies are within similar ranges of kappa values, so direct spectrum fitting often leads to systematic biases due to corner frequency and magnitude. In response to the significantly increased seismicity rate in Oklahoma, several local networks have been deployed following major earthquakes: the Prague, Pawnee and Fairview earthquakes. Each network provides dense observations within 20 km surrounding the fault zone, recording tens of thousands of aftershocks between M1 to M3. Using near-field recordings in the Prague area, we apply a stacking approach to separate path/site and source effects. The resulting source parameters are consistent with parameters derived from ground motion and spectral ratio methods from other studies; they exhibit spatial coherence within the fault zone for different fault patches. We apply these source parameter constraints in an analysis of kappa values for stations within 20 km of the fault zone. The resulting kappa values show significantly reduced variability compared to those from direct spectral fitting without constraints on the source spectrum; they are not biased by earthquake magnitudes. With these improvements, we plan to apply the stacking analysis to other local arrays to analyze source properties and site characteristics. For selected individual earthquakes, we will also use individual-pair empirical Green's function (EGF) analysis to validate the source parameter estimations.
Registering parameters and granules of wave observations: IMAGE RPI success story
NASA Astrophysics Data System (ADS)
Galkin, I. A.; Charisi, A.; Fung, S. F.; Benson, R. F.; Reinisch, B. W.
2015-12-01
Modern metadata systems strive to help scientists locate data relevant to their research and then retrieve them quickly. Success of this mission depends on the organization and completeness of metadata. Each relevant data resource has to be registered; each content has to be described; each data file has to be accessible. Ultimately, data discoverability is about the practical ability to describe data content and location. Correspondingly, data registration has a "Parameter" level, at which content is specified by listing available observed properties (parameters), and a "Granule" level, at which download links are given to data records (granules). Until recently, both parameter- and granule-level data registrations were accomplished at NASA Virtual System Observatory easily by listing provided parameters and building Granule documents with URLs to the datafile locations, usually those at NASA CDAWeb data warehouse. With the introduction of the Virtual Wave Observatory (VWO), however, the parameter/granule concept faced a scalability challenge. The wave phenomenon content is rich with descriptors of the wave generation, propagation, interaction with propagation media, and observation processes. Additionally, the wave phenomenon content varies from record to record, reflecting changes in the constituent processes, making it necessary to generate granule documents at sub-minute resolution. We will present the first success story of registering 234,178 records of IMAGE Radio Plasma Imager (RPI) plasmagram data and Level 2 derived data products in ESPAS (near-Earth Space Data Infrastructure for e-Science), using the VWO-inspired wave ontology. The granules are arranged in overlapping display and numerical data collections. Display data include (a) auto-prospected plasmagrams of potential interest, (b) interesting plasmagrams annotated by human analysts or software, and (c) spectacular plasmagrams annotated by analysts as publication-quality examples of the RPI science. Numerical data products include plasmagram-derived records containing signatures of local and remote signal propagation, as well as field-aligned profiles of electron density in the plasmasphere. Registered granules of RPI observations are available in ESPAS for their content-targeted search and retrieval.
Obenaus, Manuel; Burgsteiner, Harald
2014-01-01
To increase the patient's acceptance of electronic health records and understanding for their laboratory findings a web application was developed which presents all parameters and possible deviations of standard values in a clear way and visualizes the time based trend of all recorded parameters graphically. Documents corresponding to the Clinical document architecture (CDA) R2 laboratory reports standard and a rapid prototyping framework called Groovy on Grails were used. This work shows, that it is possible to create a useful, standards based tool for patients and physicians with comparatively few resources - an application that could be in similar form a part of an electronic Health Record (EHR) system like the Austrian electronic Health Record (ELGA).
77 FR 15587 - Privacy Act of 1974; Implementation
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-16
... in DMDC 11, entitled ``Investigative Records Repository'', when investigatory material is compiled... Records Repository. (i) Exemptions: (A) Investigatory material compiled for law enforcement purposes may...
Code of Federal Regulations, 2011 CFR
2011-04-01
... AND ETHICS; AND INFORMATION AND REQUESTS Regulations Pertaining to the Privacy of Individuals and Systems of Records Maintained by the Commission § 200.302 Definitions. The following definitions shall apply for purposes of this subpart: (a) The terms individual, maintain, record, system of records, and...
Code of Federal Regulations, 2010 CFR
2010-04-01
... AND ETHICS; AND INFORMATION AND REQUESTS Regulations Pertaining to the Privacy of Individuals and Systems of Records Maintained by the Commission § 200.302 Definitions. The following definitions shall apply for purposes of this subpart: (a) The terms individual, maintain, record, system of records, and...
Privacy Impact Assessment for the Lead-based Paint System of Records
The Lead-based Paint System of Records collects personally identifiable information, test scores, and submitted fees. Learn how this data is collected, how it will be used, access to the data, the purpose of data collection, and record retention policies.
49 CFR Appendix to Part 10 - Exemptions
Code of Federal Regulations, 2013 CFR
2013-10-01
... Federal Records Centers located throughout the country. 2. FHWA Investigations Case File System... following systems of records that consist of (a) Information compiled for the purpose of identifying...) (Publication of existence and character of system); (e)(6) (Ensure records are accurate, relevant, timely, and...
49 CFR Appendix to Part 10 - Exemptions
Code of Federal Regulations, 2014 CFR
2014-10-01
... Federal Records Centers located throughout the country. 2. FHWA Investigations Case File System... following systems of records that consist of (a) Information compiled for the purpose of identifying...) (Publication of existence and character of system); (e)(6) (Ensure records are accurate, relevant, timely, and...
49 CFR Appendix to Part 10 - Exemptions
Code of Federal Regulations, 2012 CFR
2012-10-01
... Federal Records Centers located throughout the country. 2. FHWA Investigations Case File System... following systems of records that consist of (a) Information compiled for the purpose of identifying...) (Publication of existence and character of system); (e)(6) (Ensure records are accurate, relevant, timely, and...
Together and apart: a typology of re-partnering in old age.
Koren, Chaya
2014-08-01
The human need for love, friendship, and physical contact, and the fear of loneliness do not diminish with age. Widowhood and late-life divorce and increased life expectancy are likely to lead to alternative relationships, such as re-partnering. The purpose of this paper is to explore interplays between emotional and physical components of re-partnering in old age. Theoretical sampling of 20 couples included men who re-partnered at the age of 65+ years and women at the age of 60+ years, following termination of lifelong marriages due to death or divorce. Living arrangements included married or unmarried cohabitation under the same roof or in separate homes. Forty semi-structured interviews were tape-recorded and transcribed verbatim. The couple was the unit of analysis. Interplays between physical and emotional dimensions were examined using five abductive parameters derived from data analysis resulting in a fourfold typology of emotional and physical closeness/distance in re-partnering in old age: (1) living together (physically and emotionally); (2) living apart (physically) together (emotionally); (3) living together (physically) apart (emotionally); and (4) living apart (physically and emotionally). Findings revealed types of partner relationships that are different from lifelong marriages. The typology could help professionals working with older persons regarding what to expect in re-partnering in old age and be included in developmental theories as an option in old age. A quantitative tool for research and therapy purposes, entitled The Re-partnering in Old Age Typology Scale (RPOAT Scale), based on abductive parameters, could be established for measuring re-partnering relationship quality and classifying re-partnering couples.
Medical Area Body Network. Final rule.
2012-09-11
This document expands the Commission's Medical Device Radiocommunications Service (MedRadio) rules to permit the development of new Medical Body Area Network (MBAN) devices in the 2360-2400 MHz band. The MBAN technology will provide a flexible platform for the wireless networking of multiple body transmitters used for the purpose of measuring and recording physiological parameters and other patient information or for performing diagnostic or therapeutic functions, primarily in health care facilities. This platform will enhance patient safety, care and comfort by reducing the need to physically connect sensors to essential monitoring equipment by cables and wires. This decision is the latest in a series of actions to expand the spectrum available for wireless medical use. The Commission finds that the risk of increased interference is minimal and is greatly outweighed by the benefits of the MBAN rules.
Estimating the mutual information of an EEG-based Brain-Computer Interface.
Schlögl, A; Neuper, C; Pfurtscheller, G
2002-01-01
An EEG-based Brain-Computer Interface (BCI) could be used as an additional communication channel between human thoughts and the environment. The efficacy of such a BCI depends mainly on the transmitted information rate. Shannon's communication theory was used to quantify the information rate of BCI data. For this purpose, experimental EEG data from four BCI experiments was analyzed off-line. Subjects imaginated left and right hand movements during EEG recording from the sensorimotor area. Adaptive autoregressive (AAR) parameters were used as features of single trial EEG and classified with linear discriminant analysis. The intra-trial variation as well as the inter-trial variability, the signal-to-noise ratio, the entropy of information, and the information rate were estimated. The entropy difference was used as a measure of the separability of two classes of EEG patterns.
Aerodynamic static stability and control effectiveness of a parametric shuttle launch configuration
NASA Technical Reports Server (NTRS)
Ramsey, P. E.
1972-01-01
Experimental aerodynamic investigations were conducted in the NASA/MSFC 14-inch Trisonic Wind Tunnel on a 0.004-scale model of the NR ATP baseline Shuttle launch configuration. The test model consisted of the NR ATP baseline orbiter, external tank, and SRB's with nozzles. Six component aerodynamic force and moment data were recorded over an angle of attack range from minus 10 deg to 10 deg at zero degrees sideslip and angle of sideslip range of minus 10 deg to 10 deg at zero angle of attack for a Mach range of 0.6 to 4.96. Rudder flare was constant at 10 deg during the entire test. The purpose of the test was to define the performance, stability, and control characteristics of the launch configuration as well as to investigate the buildup effect of two geometrical parameters.
Spelten, Evelien R; Martin, Linda; Gitsels, Janneke T; Pereboom, Monique T R; Hutton, Eileen K; van Dulmen, Sandra
2015-01-01
video recording studies have been found to be complex; however very few studies describe the actual introduction and enrolment of the study, the resulting dataset and its interpretation. In this paper we describe the introduction and the use of video recordings of health care provider (HCP)-client interactions in primary care midwifery for research purposes. We also report on the process of data management, data coding and the resulting data set. we describe our experience in undertaking a study using video recording to assess the interaction of the midwife and her client in the first antenatal consultation, in a real life clinical practice setting in the Netherlands. Midwives from six practices across the Netherlands were recruited to videotape 15-20 intakes. The introduction, complexity of the study and intrusiveness of the study were discussed within the research group. The number of valid recordings and missing recordings was measured; reasons not to participate, non-response analyses, and the inter-rater reliability of the coded videotapes were assessed. Video recordings were supplemented by questionnaires for midwives and clients. The Roter Interaction Analysis System (RIAS) was used for coding as well as an obstetric topics scale. at the introduction of the study, more initial hesitation in co-operation was found among the midwives than among their clients. The intrusive nature of the recording on the interaction was perceived to be minimal. The complex nature of the study affected recruitment and data collection. Combining the dataset with the questionnaires and medical records proved to be a challenge. The final dataset included videotapes of 20 midwives (7-23 recordings per midwife). Of the 460 eligible clients, 324 gave informed consent. The study resulted in a significant dataset of first antenatal consultations involving recording 269 clients and 194 partners. video recording of midwife-client interaction was both feasible and challenging and resulted in a unique dataset of recordings of midwife-client interaction. Video recording studies will benefit from a tight design, and vigilant monitoring during the data collection to ensure effective data collection. We provide suggestions to promote successful introduction of video recording for research purposes. Copyright © 2014 Elsevier Ltd. All rights reserved.
Defining care products to finance health care in the Netherlands.
Westerdijk, Machiel; Zuurbier, Joost; Ludwig, Martijn; Prins, Sarah
2012-04-01
A case-mix project started in the Netherlands with the primary goal to define a complete set of health care products for hospitals. The definition of the product structure was completed 4 years later. The results are currently being used for billing purposes. This paper focuses on the methodology and techniques that were developed and applied in order to define the casemix product structure. The central research question was how to develop a manageable product structure, i.e., a limited set of hospital products, with acceptable cost homogeneity. For this purpose, a data warehouse with approximately 1.5 million patient records from 27 hospitals was build up over a period of 3 years. The data associated with each patient consist of a large number of a priori independent parameters describing the resource utilization in different stages of the treatment process, e.g., activities in the operating theatre, the lab and the radiology department. Because of the complexity of the database, it was necessary to apply advanced data analysis techniques. The full analyses process that starts from the database and ends up with a product definition consists of four basic analyses steps. Each of these steps has revealed interesting insights. This paper describes each step in some detail and presents the major results of each step. The result consists of 687 product groups for 24 medical specialties used for billing purposes.
NASA Astrophysics Data System (ADS)
Luo, Ning; Illman, Walter A.
2016-09-01
Analyses are presented of long-term hydrographs perturbed by variable pumping/injection events in a confined aquifer at a municipal water-supply well field in the Region of Waterloo, Ontario (Canada). Such records are typically not considered for aquifer test analysis. Here, the water-level variations are fingerprinted to pumping/injection rate changes using the Theis model implemented in the WELLS code coupled with PEST. Analyses of these records yield a set of transmissivity ( T) and storativity ( S) estimates between each monitoring and production borehole. These individual estimates are found to poorly predict water-level variations at nearby monitoring boreholes not used in the calibration effort. On the other hand, the geometric means of the individual T and S estimates are similar to those obtained from previous pumping tests conducted at the same site and adequately predict water-level variations in other boreholes. The analyses reveal that long-term municipal water-level records are amenable to analyses using a simple analytical solution to estimate aquifer parameters. However, uniform parameters estimated with analytical solutions should be considered as first rough estimates. More accurate hydraulic parameters should be obtained by calibrating a three-dimensional numerical model that rigorously captures the complexities of the site with these data.
NASA Astrophysics Data System (ADS)
Jamlos, Mohd Aminudin; Ismail, Abdul Hafiizh; Jamlos, Mohd Faizal; Narbudowicz, Adam
2017-01-01
Hybrid graphene-copper ultra-wideband array sensor applied to microwave imaging technique is successfully used in detecting and visualizing tumor inside human brain. The sensor made of graphene coated film for the patch while copper for both the transmission line and parasitic element. The hybrid sensor performance is better than fully copper sensor. Hybrid sensor recorded wider bandwidth of 2.0-10.1 GHz compared with fully copper sensor operated from 2.5 to 10.1 GHz. Higher gain of 3.8-8.5 dB is presented by hybrid sensor, while fully copper sensor stated lower gain ranging from 2.6 to 6.7 dB. Both sensors recorded excellent total efficiency averaged at 97 and 94%, respectively. The sensor used for both transmits equivalent signal and receives backscattering signal from stratified human head model in detecting tumor. Difference in the data of the scattering parameters recorded from the head model with presence and absence of tumor is used as the main data to be further processed in confocal microwave imaging algorithm in generating image. MATLAB software is utilized to analyze S-parameter signals obtained from measurement. Tumor presence is indicated by lower S-parameter values compared to higher values recorded by tumor absence.
Code of Federal Regulations, 2011 CFR
2011-07-01
... operating parameter value and corrective action taken. (6) For each continuous monitoring system, records... operator may retain records on microfilm, computer disks, magnetic tape, or microfiche; and (3) The owner or operator may report required information on paper or on a labeled computer disk using commonly...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rahman, Nur Aira Abd, E-mail: nur-aira@nuclearmalaysia.gov.my; Yussup, Nolida; Ibrahim, Maslina Bt. Mohd
Neutron Activation Analysis (NAA) had been established in Nuclear Malaysia since 1980s. Most of the procedures established were done manually including sample registration. The samples were recorded manually in a logbook and given ID number. Then all samples, standards, SRM and blank were recorded on the irradiation vial and several forms prior to irradiation. These manual procedures carried out by the NAA laboratory personnel were time consuming and not efficient. Sample registration software is developed as part of IAEA/CRP project on ‘Development of Process Automation in the Neutron Activation Analysis (NAA) Facility in Malaysia Nuclear Agency (RC17399)’. The objective ofmore » the project is to create a pc-based data entry software during sample preparation stage. This is an effective method to replace redundant manual data entries that needs to be completed by laboratory personnel. The software developed will automatically generate sample code for each sample in one batch, create printable registration forms for administration purpose, and store selected parameters that will be passed to sample analysis program. The software is developed by using National Instruments Labview 8.6.« less
Latash, M L; Goodman, S R
1994-01-01
The purpose of this work has been to develop a model of electromyographic (EMG) patterns during single-joint movements based on a version of the equilibrium-point hypothesis, a method for experimental reconstruction of the joint compliant characteristics, the dual-strategy hypothesis, and a kinematic model of movement trajectory. EMG patterns are considered emergent properties of hypothetical control patterns that are equally affected by the control signals and peripheral feedback reflecting actual movement trajectory. A computer model generated the EMG patterns based on simulated movement kinematics and hypothetical control signals derived from the reconstructed joint compliant characteristics. The model predictions have been compared to published recordings of movement kinematics and EMG patterns in a variety of movement conditions, including movements over different distances, at different speeds, against different-known inertial loads, and in conditions of possible unexpected decrease in the inertial load. Changes in task parameters within the model led to simulated EMG patterns qualitatively similar to the experimentally recorded EMG patterns. The model's predictive power compares it favourably to the existing models of the EMG patterns. Copyright © 1994. Published by Elsevier Ltd.
Hani, Younes Mohamed Ismail; Turies, Cyril; Palluel, Olivier; Delahaut, Laurence; Gaillet, Véronique; Bado-Nilles, Anne; Porcher, Jean-Marc; Geffard, Alain; Dedourge-Geffard, Odile
2018-06-01
The development of predictive, sensitive and reliable biomarkers is of crucial importance for aquatic biomonitoring to assess the effects of chemical substances on aquatic organisms, especially when it comes to combined effects with other stressors (e.g. temperature). The first purpose of the present study was to evaluate the single and combined effects of 90 days of exposure to an environmental cadmium concentration (0.5 μg L -1 ) and two water temperatures (16 and 21 °C) on different parameters. These parameters are involved in (i) the antioxidant system (superoxide dismutase activity -SOD- and total glutathione levels -GSH-), (ii) the energy metabolism, i.e. energy reserves (glycogen, lipids, proteins) and digestive enzymes (trypsin, amylase, intestinal alkaline phosphatase -IAP-), and (iii) biometric parameters (weight, length, Fulton's condition factor, and the gonadosomatic index -GSI-) of threespine stickleback (Gasterosteus aculeatus). The second purpose was to determine the interest of the three digestive enzymes as biomarkers in comparison with the other parameters. The higher temperature (21 °C) impacted the anti-oxidant and energy reserve parameters. In liver, GSH levels increased on day 60, while SOD decreased on days 15 and 90, with a significant decrease of protein and lipid energy reserves on day 90. In muscle, the higher temperature decreased SOD activity only on day 90. G. aculeatus biometric parameters were also impacted by the higher temperature, which limited stickleback growth after 90 days of exposure. In female sticklebacks, the GSI peaked on day 60 and decreased sharply on day 90, while the highest values were reached at day 90 in the control groups, suggesting impaired reproduction in sticklebacks raised at 21 °C. These results suggest that 21 °C is an upper-limit temperature for long-term physiological processes in sticklebacks. In contrast, very low-concentration cadmium exposure had no effect on classical biomarkers (energy reserves, antioxidant parameters, biometric parameters). However, digestive enzymes showed an interesting sensitivity to cadmium, which was emphasized by high temperature. The activity of the three digestive enzymes decreased significantly on day 90 when sticklebacks were exposed to cadmium alone, while the decrease was stronger and was recorded earlier (from day 15) when they were exposed to the cadmium-temperature combination. Compared to conventional measurements, digestive enzymes responded rapidly. This could be an important advantage for them to be used as early warning tools to reflect the health status of organisms, particularly for trypsin and IAP activities. Copyright © 2018 Elsevier B.V. All rights reserved.
Serdaroğlu, Meltem; Nacak, Berker; Karabıyıkoğlu, Merve
2017-01-01
The objective of this study was to investigate the effect of using gelled emulsion (olive oil 46%, inulin 9%, gelatin 3%) as fat replacer on some quality parameters of chicken patties. For this purpose GE, prepared with olive oil, gelatin and inulin was replaced with beef fat at a level of 0%, 25%, 50%, 100% (C, G25, G50, G100). In this study syneresis, thermal stability, centrifuge and creaming stability of gelled emulsion were analyzed. Chemical composition, technological paramerers (cooking yield, water holding capacity, diameter reduction, fat and moisture retention) and textural and sensory properites were evaluated in comparision to control patties. High thermal stability was recorded in GE (93%), also creaming stability results showed that GE protected its stability without any turbidity and separation of the layer. The complete replacement of beef fat with GE showed detrimental effect on all investigated cooking characteristics except fat retention. Replacement of beef fat with GE at a level of 50% resulted similar cooking characteristics with C samples. Color parameters of samples were affected by GE addition, higher CIE b* values observed with respect to GE concentration. The presence of GE significantly affected textural behaviors of samples ( p <0.05). Our results showed that GE prepared with inulin and olive oil is a viable fat replacer for the manufacture of chicken patty.
Initial FDG-PET/CT predicts survival in adults Ewing sarcoma family of tumors
Jamet, Bastien; Carlier, Thomas; Campion, Loic; Bompas, Emmanuelle; Girault, Sylvie; Borrely, Fanny; Ferrer, Ludovic; Rousseau, Maxime; Venel, Yann; Kraeber-Bodéré, Françoise; Rousseau, Caroline
2017-01-01
Purpose The aim of this retrospective study was to determine, at baseline, the prognostic value of different FDG-PET/CT quantitative parameters in a homogenous Ewing Sarcoma Family of Tumors (ESFT) adult population, compared with clinically relevant prognostic factors. Methods Adult patients from 3 oncological centers, all with proved ESFT, were retrospectively included. Quantitative FDG-PET/CT parameters (SUV (maximum, peak and mean), metabolic tumor volume (MTV) and total lesion glycolysis (TLG) of the primary lesion of each patient were recorded before treatment, as well as usual clinical prognostic factors (stage of disease, location, tumor size, gender and age). Then, their relation with progression free survival (PFS) and overall survival (OS) was evaluated. Results 32 patients were included. Median age was 21 years (range, 15 to 61). Nineteen patients (59%) were initially metastatic. On multivariate analysis, high SUVmax remained independent predictor of worst OS (p=0.02) and PFS (p=0.019), metastatic disease of worst PFS (p=0.01) and high SUVpeak of worst OS (p=0.01). Optimal prognostic cut-off of SUVpeak was found at 12.5 in multivariate analyses for PFS and OS (p=0.0001). Conclusions FDG-PET/CT, recommended at ESFT diagnosis for initial staging, can be a useful tool for predicting long-term adult patients outcome through semi-quantitative parameters. PMID:29100369
Selection of optimal multispectral imaging system parameters for small joint arthritis detection
NASA Astrophysics Data System (ADS)
Dolenec, Rok; Laistler, Elmar; Stergar, Jost; Milanic, Matija
2018-02-01
Early detection and treatment of arthritis is essential for a successful outcome of the treatment, but it has proven to be very challenging with existing diagnostic methods. Novel methods based on the optical imaging of the affected joints are becoming an attractive alternative. A non-contact multispectral imaging (MSI) system for imaging of small joints of human hands and feet is being developed. In this work, a numerical simulation of the MSI system is presented. The purpose of the simulation is to determine the optimal design parameters. Inflamed and unaffected human joint models were constructed with a realistic geometry and tissue distributions, based on a MRI scan of a human finger with a spatial resolution of 0.2 mm. The light transport simulation is based on a weighted-photon 3D Monte Carlo method utilizing CUDA GPU acceleration. An uniform illumination of the finger within the 400-1100 nm spectral range was simulated and the photons exiting the joint were recorded using different acceptance angles. From the obtained reflectance and transmittance images the spectral and spatial features most indicative of inflammation were identified. Optimal acceptance angle and spectral bands were determined. This study demonstrates that proper selection of MSI system parameters critically affects ability of a MSI system to discriminate the unaffected and inflamed joints. The presented system design optimization approach could be applied to other pathologies.
Sussadee, Metita; Phavaphutanon, Janjira; Kornkaewrat, Kornchai
2015-01-01
The purpose of the present study was to establish normal electroretinogram (ERG) parameters using 56 normal eyes of four dog breeds common in Thailand: poodle, Labrador retriever, Thai ridgeback, and Thai Bangkaew. Standard ERG findings were bilaterally recorded using a handheld multi-species ERG unit with an ERG-jet lens electrode for 28 dogs under preanesthesia with diazepam, anesthesia with propofol, and anesthesia maintenance with isoflurane. There were significant differences in the mean values of ERG amplitudes and implicit times among the four dog breeds (p < 0.05) except for the b-wave implicit time of the photopic 30 Hz flicker response with 3 cd.s/m2 (p = 0.610). Out of the four breeds, Thai Bangkaew had the longest implicit time (p < 0.001) of scotopic low intensity responses, b-wave of scotopic standard intensity responses (3 cd.s/m2), a-wave of the higher intensity response (10 cd.s/m2), and a-wave of the photopic single flash response (3 cd.s/m2). For the b/a ratio, only the ratio of the Cone response was significantly different among the different breeds. In this summary, normal ERG parameters for four dog breeds were reported. Data from the investigation supported the hypothesis that determination of breed-specific limits of normality for ERG responses is necessary for individual clinics and laboratories. PMID:25269713
Women use voice parameters to assess men's characteristics
Bruckert, Laetitia; Liénard, Jean-Sylvain; Lacroix, André; Kreutzer, Michel; Leboucher, Gérard
2005-01-01
The purpose of this study was: (i) to provide additional evidence regarding the existence of human voice parameters, which could be reliable indicators of a speaker's physical characteristics and (ii) to examine the ability of listeners to judge voice pleasantness and a speaker's characteristics from speech samples. We recorded 26 men enunciating five vowels. Voices were played to 102 female judges who were asked to assess vocal attractiveness and speakers' age, height and weight. Statistical analyses were used to determine: (i) which physical component predicted which vocal component and (ii) which vocal component predicted which judgment. We found that men with low-frequency formants and small formant dispersion tended to be older, taller and tended to have a high level of testosterone. Female listeners were consistent in their pleasantness judgment and in their height, weight and age estimates. Pleasantness judgments were based mainly on intonation. Female listeners were able to correctly estimate age by using formant components. They were able to estimate weight but we could not explain which acoustic parameters they used. However, female listeners were not able to estimate height, possibly because they used intonation incorrectly. Our study confirms that in all mammal species examined thus far, including humans, formant components can provide a relatively accurate indication of a vocalizing individual's characteristics. Human listeners have the necessary information at their disposal; however, they do not necessarily use it. PMID:16519239
2017-01-01
The objective of this study was to investigate the effect of using gelled emulsion (olive oil 46%, inulin 9%, gelatin 3%) as fat replacer on some quality parameters of chicken patties. For this purpose GE, prepared with olive oil, gelatin and inulin was replaced with beef fat at a level of 0%, 25%, 50%, 100% (C, G25, G50, G100). In this study syneresis, thermal stability, centrifuge and creaming stability of gelled emulsion were analyzed. Chemical composition, technological paramerers (cooking yield, water holding capacity, diameter reduction, fat and moisture retention) and textural and sensory properites were evaluated in comparision to control patties. High thermal stability was recorded in GE (93%), also creaming stability results showed that GE protected its stability without any turbidity and separation of the layer. The complete replacement of beef fat with GE showed detrimental effect on all investigated cooking characteristics except fat retention. Replacement of beef fat with GE at a level of 50% resulted similar cooking characteristics with C samples. Color parameters of samples were affected by GE addition, higher CIE b* values observed with respect to GE concentration. The presence of GE significantly affected textural behaviors of samples (p<0.05). Our results showed that GE prepared with inulin and olive oil is a viable fat replacer for the manufacture of chicken patty. PMID:28747823
Quality assurance of dynamic parameters in volumetric modulated arc therapy.
Manikandan, A; Sarkar, B; Holla, R; Vivek, T R; Sujatha, N
2012-07-01
The purpose of this study was to demonstrate quality assurance checks for accuracy of gantry speed and position, dose rate and multileaf collimator (MLC) speed and position for a volumetric modulated arc treatment (VMAT) modality (Synergy S; Elekta, Stockholm, Sweden), and to check that all the necessary variables and parameters were synchronous. Three tests (for gantry position-dose delivery synchronisation, gantry speed-dose delivery synchronisation and MLC leaf speed and positions) were performed. The average error in gantry position was 0.5° and the average difference was 3 MU for a linear and a parabolic relationship between gantry position and delivered dose. In the third part of this test (sawtooth variation), the maximum difference was 9.3 MU, with a gantry position difference of 1.2°. In the sweeping field method test, a linear relationship was observed between recorded doses and distance from the central axis, as expected. In the open field method, errors were encountered at the beginning and at the end of the delivery arc, termed the "beginning" and "end" errors. For MLC position verification, the maximum error was -2.46 mm and the mean error was 0.0153 ±0.4668 mm, and 3.4% of leaves analysed showed errors of >±1 mm. This experiment demonstrates that the variables and parameters of the Synergy S are synchronous and that the system is suitable for delivering VMAT using a dynamic MLC.
Somkuwar, R G; Bahetwar, Anita; Khan, I; Satisha, J; Ramteke, S D; Itroutwar, Prerna; Bhongale, Aarti; Oulkar, Dashrath
2014-11-01
The study on photosynthetic activity and biochemical parameters in Thompson Seedless grapes grafted on Dog Ridge rootstock and its impact on growth, yield and amino acid profile at various stages of berry development was conducted during the year 2012-2013. Leaf and berry samples from ten year old vines of Thompson Seedless were collected at different growth and berry developmental stages. The analysis showed difference in photosynthetic activity, biochemical parameters and amino acid status with the changes in berry development stage. Higher photosynthetic rate of 17.39 umol cm(-2) s(-1) was recorded during 3-4mm berry size and the lowest (10.08 umol cm(-2) s(-1)) was recorded during the veraison stage. The photosynthetic activity showed gradual decrease with the onset of harvest while the different biochemical parameters showed increase and decrease from one stage to another in both berry and leaves. Changes in photosynthetic activity and biochemical parameters thereby affected the growth, yield and amino acid content of the berry. Positive correlation of leaf area and photosynthetic rate was recorded during the period of study. Reducing sugar (352.25 mg g(-1)) and total carbohydrate (132.52 mg g(-1)) was more in berries as compared to leaf. Amino acid profile showed variations in different stages of berry development. Marked variations in photosynthetic as well as biochemical and amino acid content at various berry development stages was recorded and thereby its cumulative effect on the development of fruit quality.
Ballestros Peña, Sendoa; Lorrio Palomino, Sergio; Ariz Zubiaur, Mónica
2012-11-01
BASICS: A Prehospital Care and Transfer Recording (PCTR) is an out-of-hospital medical recording. This paper was made to assess and compare the level of fulfillment of the basic parameters of the PCTR developed by the Life Support Units with nurses (Life Support Units with Nurse, LSUwN and without nurses (Basic Life Support Units, BLSU) from SAMUR Bilbao in 2010. A descriptive, retrospective and comparative study was performed by analysing a randomized sample of 660 PCTR (precision 3%), aiming to check the fulfillment of the basic data. 98.33% of total recordings were readable. In overall, fulfillment rate was 90.31% (CI 89.24- 97.3 71%) of all basic parameters for LSUwN PCTR and 84.81% (CI 83.56 to 86%) for BLSU. 34.1% of PCTR were completely and correctly fulfilled. The LSUwN scored significantly better (p < 0.000). There were recording failures in "date and time", "address" and "physical examination". There were differences between the recording of clinical and administrative information (88.64% vs 86.72%, p = 0.02). In order to consider a parameter has optimal, it has to reach 100% of fulfillment. If it doesn't, and its score reaches no more than 80%, it should be reviewed. In this case, the results would be considered acceptable, but the administrative items of BLSU records, and allergies in both units should be strengthened. LSUwN has obtained better scores. The need of recording clinical information must be instilled as evidence of quality care.
Evaluation of sequential images for photogrammetrically point determination
NASA Astrophysics Data System (ADS)
Kowalczyk, M.
2011-12-01
Close range photogrammetry encounters many problems with reconstruction of objects three-dimensional shape. Relative orientation parameters of taken photos makes usually key role leading to right solution of this problem. Automation of technology process is hardly performed due to recorded scene complexity and configuration of camera positions. This configuration makes the process of joining photos into one set usually impossible automatically. Application of camcorder is the solution widely proposed in literature for support in 3D models creation. Main advantages of this tool are connected with large number of recorded images and camera positions. Exterior orientation changes barely between two neighboring frames. Those features of film sequence gives possibilities for creating models with basic algorithms, working faster and more robust, than with remotely taken photos. The first part of this paper presents results of experiments determining interior orientation parameters of some sets of frames, presenting three-dimensional test field. This section describes calibration repeatability of film frames taken from camcorder. It is important due to stability of interior camera geometric parameters. Parametric model of systematical errors was applied for correcting images. Afterwards a short film of the same test field had been taken for determination of check points group. This part has been done for controlling purposes of camera application in measurement tasks. Finally there are presented some results of experiments which compare determination of recorded object points in 3D space. In common digital photogrammetry, where separate photos are used, first levels of image pyramids are taken to connect with feature based matching. This complicated process creates a lot of emergencies, which can produce false detections of image similarities. In case of digital film camera, authors of publications avoid this dangerous step, going straightly to area based matching, aiming high degree of similarity for two corresponding film frames. First approximation, in establishing connections between photos, comes from whole image distance. This image distance method can work with more than just two dimensions of translation vector. Scale and angles are also used for improving image matching. This operation creates more similar looking frames where corresponding characteristic points lays close to each other. Procedure searching for pairs of points works faster and more accurately, because analyzed areas can be reduced. Another proposed solution comes from image created by adding differences between particular frames, gives more rough results, but works much faster than standard matching.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Evaluating Motor Vehicle Driving Record Data The purpose of this appendix is to outline the procedures... Vehicle Driving Record Data C Appendix C to Part 240 Transportation Other Regulations Relating to... that railroads consider the motor vehicle driving record of each person prior to issuing him or her...
Code of Federal Regulations, 2012 CFR
2012-10-01
... Vehicle Driving Record Data The purpose of this appendix is to outline the procedures available to... Vehicle Driving Record Data C Appendix C to Part 242 Transportation Other Regulations Relating to... provisions require that railroads consider the motor vehicle driving record of each person prior to issuing...
32 CFR Appendix C to Part 310 - DoD Blanket Routine Uses
Code of Federal Regulations, 2013 CFR
2013-07-01
... to the Office of Personnel Management A record from a system of records subject to the Privacy Act... General Services Administration (GSA) for the purpose of records management inspections conducted under... paragraph (c) of § 310.22 of subpart E) A. Routine Use—Law Enforcement If a system of records maintained by...
10 CFR 9.80 - Disclosure of record to persons other than the individual to whom it pertains.
Code of Federal Regulations, 2010 CFR
2010-01-01
... has provided the agency with advance adequate written assurance that the record will be used solely as a statistical research or reporting record and the record is transferred in a form that is not individually identifiable. The advance written statement of assurance shall (i) state the purpose for which the...
NASA Astrophysics Data System (ADS)
Prathabrao, M.; Nawawi, Azli; Sidek, Noor Azizah
2017-04-01
Radio Frequency Identification (RFID) system has multiple benefits which can improve the operational efficiency of the organization. The advantages are the ability to record data systematically and quickly, reducing human errors and system errors, update the database automatically and efficiently. It is often more readers (reader) is needed for the installation purposes in RFID system. Thus, it makes the system more complex. As a result, RFID network planning process is needed to ensure the RFID system works perfectly. The planning process is also considered as an optimization process and power adjustment because the coordinates of each RFID reader to be determined. Therefore, algorithms inspired by the environment (Algorithm Inspired by Nature) is often used. In the study, PSO algorithm is used because it has few number of parameters, the simulation time is fast, easy to use and also very practical. However, PSO parameters must be adjusted correctly, for robust and efficient usage of PSO. Failure to do so may result in disruption of performance and results of PSO optimization of the system will be less good. To ensure the efficiency of PSO, this study will examine the effects of two parameters on the performance of PSO Algorithm in RFID tag coverage optimization. The parameters to be studied are the swarm size and iteration number. In addition to that, the study will also recommend the most optimal adjustment for both parameters that is, 200 for the no. iterations and 800 for the no. of swarms. Finally, the results of this study will enable PSO to operate more efficiently in order to optimize RFID network planning system.
Uloza, Virgilijus; Padervinskis, Evaldas; Uloziene, Ingrida; Saferis, Viktoras; Verikas, Antanas
2015-09-01
The aim of the present study was to evaluate the reliability of the measurements of acoustic voice parameters obtained simultaneously using oral and contact (throat) microphones and to investigate utility of combined use of these microphones for voice categorization. Voice samples of sustained vowel /a/ obtained from 157 subjects (105 healthy and 52 pathological voices) were recorded in a soundproof booth simultaneously through two microphones: oral AKG Perception 220 microphone (AKG Acoustics, Vienna, Austria) and contact (throat) Triumph PC microphone (Clearer Communications, Inc, Burnaby, Canada) placed on the lamina of thyroid cartilage. Acoustic voice signal data were measured for fundamental frequency, percent of jitter and shimmer, normalized noise energy, signal-to-noise ratio, and harmonic-to-noise ratio using Dr. Speech software (Tiger Electronics, Seattle, WA). The correlations of acoustic voice parameters in vocal performance were statistically significant and strong (r = 0.71-1.0) for the entire functional measurements obtained for the two microphones. When classifying into healthy-pathological voice classes, the oral-shimmer revealed the correct classification rate (CCR) of 75.2% and the throat-jitter revealed CCR of 70.7%. However, combination of both throat and oral microphones allowed identifying a set of three voice parameters: throat-signal-to-noise ratio, oral-shimmer, and oral-normalized noise energy, which provided the CCR of 80.3%. The measurements of acoustic voice parameters using a combination of oral and throat microphones showed to be reliable in clinical settings and demonstrated high CCRs when distinguishing the healthy and pathological voice patient groups. Our study validates the suitability of the throat microphone signal for the task of automatic voice analysis for the purpose of voice screening. Copyright © 2015 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Preliminary Estimation of Kappa Parameter in Croatia
NASA Astrophysics Data System (ADS)
Stanko, Davor; Markušić, Snježana; Ivančić, Ines; Mario, Gazdek; Gülerce, Zeynep
2017-12-01
Spectral parameter kappa κ is used to describe spectral amplitude decay “crash syndrome” at high frequencies. The purpose of this research is to estimate spectral parameter kappa for the first time in Croatia based on small and moderate earthquakes. Recordings of local earthquakes with magnitudes higher than 3, epicentre distances less than 150 km, and focal depths less than 30 km from seismological stations in Croatia are used. The value of kappa was estimated from the acceleration amplitude spectrum of shear waves from the slope of the high-frequency part where the spectrum starts to decay rapidly to a noise floor. Kappa models as a function of a site and distance were derived from a standard linear regression of kappa-distance dependence. Site kappa was determined from the extrapolation of the regression line to a zero distance. The preliminary results of site kappa across Croatia are promising. In this research, these results are compared with local site condition parameters for each station, e.g. shear wave velocity in the upper 30 m from geophysical measurements and with existing global shear wave velocity - site kappa values. Spatial distribution of individual kappa’s is compared with the azimuthal distribution of earthquake epicentres. These results are significant for a couple of reasons: to extend the knowledge of the attenuation of near-surface crust layers of the Dinarides and to provide additional information on the local earthquake parameters for updating seismic hazard maps of studied area. Site kappa can be used in the re-creation, and re-calibration of attenuation of peak horizontal and/or vertical acceleration in the Dinarides area since information on the local site conditions were not included in the previous studies.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 22 Foreign Relations 2 2014-04-01 2014-04-01 false Purpose. 308.1 Section 308.1 Foreign Relations PEACE CORPS IMPLEMENTATION OF THE PRIVACY ACT OF 1974 § 308.1 Purpose. The purpose of this part is to set forth the basic policies of the Peace Corps governing the maintenance of systems of records...
Code of Federal Regulations, 2011 CFR
2011-04-01
... 22 Foreign Relations 2 2011-04-01 2009-04-01 true Purpose. 308.1 Section 308.1 Foreign Relations PEACE CORPS IMPLEMENTATION OF THE PRIVACY ACT OF 1974 § 308.1 Purpose. The purpose of this part is to set forth the basic policies of the Peace Corps governing the maintenance of systems of records...
Code of Federal Regulations, 2011 CFR
2011-01-01
.... The participant's Social Security number will remain the identifier for the submission of data and... individual or other identifying particular assigned to the individual; (l) Statistical record means a record in a system of records maintained for statistical research or reporting purposes only and not used in...
34 CFR 6.4 - Central records; confidentiality.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Education Office of the Secretary, Department of Education INVENTIONS AND PATENTS (GENERAL) § 6.4 Central records; confidentiality. Central files and records shall be maintained of all inventions, patents, and... Department under such patents. Invention reports required from employees or others for the purpose of...
Wearable, multimodal, vitals acquisition unit for intelligent field triage.
Beck, Christoph; Georgiou, Julius
2016-09-01
In this Letter, the authors describe the characterisation design and development of the authors' wearable, multimodal vitals acquisition unit for intelligent field triage. The unit is able to record the standard electrocardiogram, blood oxygen and body temperature parameters and also has the unique capability to record up to eight custom designed acoustic streams for heart and lung sound auscultation. These acquisition channels are highly synchronised to fully maintain the time correlation of the signals. The unit is a key component enabling systematic and intelligent field triage to continuously acquire vital patient information. With the realised unit a novel data-set with highly synchronised vital signs was recorded. The new data-set may be used for algorithm design in vital sign analysis or decision making. The monitoring unit is the only known body worn system that records standard emergency parameters plus eight multi-channel auscultatory streams and stores the recordings and wirelessly transmits them to mobile response teams.
Coercivity mechanisms and thermal stability of thin film magnetic recording media
NASA Astrophysics Data System (ADS)
Yang, Cheng
1999-09-01
Coercivity mechanisms and thermal stability of magnetic recording media were studied. It was found that magnetization reversal mainly occurs by nucleation mechanism. The correlation was established between the c/ a ratio of Co HCP structure and other process parameters that are thought to be the dominant factors in determining the anisotropy and therefore the coercivity of Co based thin film magnetic recording media. Time decay and switching of the magnetization in thin film magnetic recording media depend on the grain size distribution and easy-axis orientation distribution according to the proposed two- energy-level model. Relaxation time is the most fundamental parameter that determines the time decay performance of the magnetic recording media. An algorithm was proposed to calculate its distribution directly from the experimental data without any presumption. It was found for the first time that the distribution of relaxation time takes the form of Weibull distribution.
NIMBUS 7 Earth Radiation Budget (ERB) Matrix User's Guide. Volume 2: Tape Specifications
NASA Technical Reports Server (NTRS)
Ray, S. N.; Vasanth, K. L.
1984-01-01
The ERB MATRIX tape is generated by an IBM 3081 computer program and is a 9 track, 1600 BPI tape. The gross format of the tape given on Page 1, shows an initial standard header file followed by data files. The standard header file contains two standard header records. A trailing documentation file (TDF) is the last file on the tape. Pages 9 through 17 describe, in detail, the standard header file and the TDF. The data files contain data for 37 different ERB parameters. Each file has data based on either a daily, 6 day cyclic, or monthly time interval. There are three types of physical records in the data files; namely, the world grid physical record, the documentation mercator/polar map projection physical record, and the monthly calibration physical record. The manner in which the data for the 37 ERB parameters are stored in the physical records comprising the data files, is given in the gross format section.
A comparison of two recorders for obtaining in-flight heart rate data.
Dahlstrom, Nicklas; Nahlinder, Staffan
2006-09-01
: Measurement of mental workload has been widely used for evaluation of aircraft design, mission analysis and assessment of pilot performance during flight operations. Heart rate is the psychophysiological measure that has been most frequently used for this purpose. The risk of interference with flight safety and pilot performance, as well as the generally constrained access to flights, make it difficult for researchers to collect in-flight heart rate data. Thus, this study was carried out to investigate whether small, non-intrusive sports recorders can be used for in-flight data collection for research purposes. Data was collected from real and simulated flights with student pilots using the Polar Team System sports recorder and the Vitaport II, a clinical and research recording device. Comparison of the data shows that in-flight heart rate data from the smaller and less intrusive sports recorder have a correlation of.981 with that from the clinical recorder, thus indicating that the sports recorder is reliable and cost-effective for obtaining heart rate data for many research situations.
Kashfi, H.; Yazdani, A. R.; Latifi, M.; Shirani Bidabadi, F.
2011-01-01
The purpose of this research is to study any effects of managerial strategies on prevention of ketosis metabolic disorder in transition period in Shahroud commercial dairy farms. For this purpose, a questionnaire was prepared in order to obtain required information about the performance of these managerial strategies, performance costs, involvement situation with disorders relying upon clinical signs and treatment and health records, producing and economic situation, and fertility rate and its costs. The considered managerial guidelines include body condition score management or type evaluation in transition period, increase in dry matter intake close to parturition, using propylene glycol, using niacin, and high-quality feeding (the importance of feed quality) in transition period. Finally and upon arrangement of data, it was possible to study any effects of mentioned managerial strategies on related variants through multiple linear regressions. Furthermore, in order to study any relation among variables, we considered Pearson correlation coefficients as well. Finally, it was revealed that any application of managerial strategies for prevention from Ketosis in transition period has a significant effect in betterment of managerial and economic parameters. PMID:23738102
Prediction of blast-induced air overpressure: a hybrid AI-based predictive model.
Jahed Armaghani, Danial; Hajihassani, Mohsen; Marto, Aminaton; Shirani Faradonbeh, Roohollah; Mohamad, Edy Tonnizam
2015-11-01
Blast operations in the vicinity of residential areas usually produce significant environmental problems which may cause severe damage to the nearby areas. Blast-induced air overpressure (AOp) is one of the most important environmental impacts of blast operations which needs to be predicted to minimize the potential risk of damage. This paper presents an artificial neural network (ANN) optimized by the imperialist competitive algorithm (ICA) for the prediction of AOp induced by quarry blasting. For this purpose, 95 blasting operations were precisely monitored in a granite quarry site in Malaysia and AOp values were recorded in each operation. Furthermore, the most influential parameters on AOp, including the maximum charge per delay and the distance between the blast-face and monitoring point, were measured and used to train the ICA-ANN model. Based on the generalized predictor equation and considering the measured data from the granite quarry site, a new empirical equation was developed to predict AOp. For comparison purposes, conventional ANN models were developed and compared with the ICA-ANN results. The results demonstrated that the proposed ICA-ANN model is able to predict blast-induced AOp more accurately than other presented techniques.
Evaluation of the IRT Parameter Invariance Property for the MCAT.
ERIC Educational Resources Information Center
Kelkar, Vinaya; Wightman, Linda F.; Luecht, Richard M.
The purpose of this study was to investigate the viability of the property of parameter invariance for the one-parameter (1P), two-parameter (2P), and three-parameter (3P) item response theory (IRT) models for the Medical College Admissions Tests (MCAT). Invariance of item parameters across different gender, ethnic, and language groups and the…
10 CFR 609.17 - Audit and access to records.
Code of Federal Regulations, 2011 CFR
2011-01-01
... access, for the purpose of audit and examination, to any pertinent books, documents, papers and records... utilize employees of other Federal agencies, independent accountants, or other persons. ...
10 CFR 609.17 - Audit and access to records.
Code of Federal Regulations, 2013 CFR
2013-01-01
... access, for the purpose of audit and examination, to any pertinent books, documents, papers and records... utilize employees of other Federal agencies, independent accountants, or other persons. ...
10 CFR 609.17 - Audit and access to records.
Code of Federal Regulations, 2014 CFR
2014-01-01
... access, for the purpose of audit and examination, to any pertinent books, documents, papers and records... utilize employees of other Federal agencies, independent accountants, or other persons. ...
10 CFR 609.17 - Audit and access to records.
Code of Federal Regulations, 2012 CFR
2012-01-01
... access, for the purpose of audit and examination, to any pertinent books, documents, papers and records... utilize employees of other Federal agencies, independent accountants, or other persons. ...
Isaacson, M D; Srinivasan, S; Lloyd, L L
2010-01-01
MathSpeak is a set of rules for non speaking of mathematical expressions. These rules have been incorporated into a computerised module that translates printed mathematics into the non-ambiguous MathSpeak form for synthetic speech rendering. Differences between individual utterances produced with the translator module are difficult to discern because of insufficient pausing between utterances; hence, the purpose of this study was to develop an algorithm for improving the synthetic speech rendering of MathSpeak. To improve synthetic speech renderings, an algorithm for inserting pauses was developed based upon recordings of middle and high school math teachers speaking mathematic expressions. Efficacy testing of this algorithm was conducted with college students without disabilities and high school/college students with visual impairments. Parameters measured included reception accuracy, short-term memory retention, MathSpeak processing capacity and various rankings concerning the quality of synthetic speech renderings. All parameters measured showed statistically significant improvements when the algorithm was used. The algorithm improves the quality and information processing capacity of synthetic speech renderings of MathSpeak. This increases the capacity of individuals with print disabilities to perform mathematical activities and to successfully fulfill science, technology, engineering and mathematics academic and career objectives.
SETTING UP FARM RECORDS TO PROVIDE FOR ANALYSIS.
ERIC Educational Resources Information Center
Illinois Univ., Urbana. Coll. of Agriculture.
RESOURCE MATERIAL ON FARM RECORD ANALYSIS FOR USE IN HIGH SCHOOL VOCATIONAL AGRICULTURE AND ADULT FARMER CLASSES WAS DESIGNED BY SUBJECT MATTER SPECIALISTS, TEACHER EDUCATORS, SUPERVISORS, AND TEACHERS TO PROVIDE TEXTUAL MATERIAL FOR STUDENTS ON THE PURPOSES OF RECORDS, ANALYSIS MEASURES, INVENTORIES, DEPRECIATION SCHEDULES, FINANCIAL TRANSACTION…
Code of Federal Regulations, 2010 CFR
2010-01-01
..., reports, and records: Falsification, reproduction, or alteration; incorrect statements. 67.403 Section 67..., logbooks, reports, and records: Falsification, reproduction, or alteration; incorrect statements. (a) No... reproduction, for fraudulent purposes, of any medical certificate under this part; or (4) An alteration of any...
Code of Federal Regulations, 2011 CFR
2011-01-01
..., reports, and records: Falsification, reproduction, or alteration; incorrect statements. 67.403 Section 67..., logbooks, reports, and records: Falsification, reproduction, or alteration; incorrect statements. (a) No... reproduction, for fraudulent purposes, of any medical certificate under this part; or (4) An alteration of any...
29 CFR 2400.6 - Procedures for requesting records.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 29 Labor 9 2010-07-01 2010-07-01 false Procedures for requesting records. 2400.6 Section 2400.6 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH REVIEW COMMISSION REGULATIONS IMPLEMENTING THE PRIVACY ACT § 2400.6 Procedures for requesting records. The purpose of this...
29 CFR 2400.6 - Procedures for requesting records.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 29 Labor 9 2011-07-01 2011-07-01 false Procedures for requesting records. 2400.6 Section 2400.6 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH REVIEW COMMISSION REGULATIONS IMPLEMENTING THE PRIVACY ACT § 2400.6 Procedures for requesting records. The purpose of this...
75 FR 52798 - State-07, Cryptographic Clearance Records
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-27
... of records, Authority for maintenance of the system, Purpose, Safeguards and Retrievability as well... INDIVIDUALS COVERED BY THE SYSTEM: All current Civil Service and Foreign Service direct hire employees of the... well as those who have already received cryptographic clearance. CATEGORIES OF RECORDS IN THE SYSTEM...
18 CFR 1301.7 - Exempt records.
Code of Federal Regulations, 2010 CFR
2010-04-01
... or intra-agency memorandums or letters which would not be available by law to a private party in... unwarranted invasion of personal privacy; (7) Records or information compiled for law enforcement purposes, but only to the extent that the production of such law enforcement records or information: (i) Could...
Code of Federal Regulations, 2010 CFR
2010-01-01
... individual or other identifying particular assigned to the individual; (l) Statistical record means a record in a system of records maintained for statistical research or reporting purposes only and not used in... when the Board is open for the conduct of Government business and does not include Saturdays, Sundays...
A simple system for detection of EEG artifacts in polysomnographic recordings.
Durka, P J; Klekowicz, H; Blinowska, K J; Szelenberger, W; Niemcewicz, Sz
2003-04-01
We present an efficient parametric system for automatic detection of electroencephalogram (EEG) artifacts in polysomnographic recordings. For each of the selected types of artifacts, a relevant parameter was calculated for a given epoch. If any of these parameters exceeded a threshold, the epoch was marked as an artifact. Performance of the system, evaluated on 18 overnight polysomnographic recordings, revealed concordance with decisions of human experts close to the interexpert agreement and the repeatability of expert's decisions, assessed via a double-blind test. Complete software (Matlab source code) for the presented system is freely available from the Internet at http://brain.fuw.edu.pl/artifacts.
Code of Federal Regulations, 2012 CFR
2012-04-01
.... (1) For purposes of this section, the term procurement means the process which leads to any award of... shall maintain records sufficient to detail the significant history of a procurement. These records...
Li, Liang; Mao, Huzhang; Ishwaran, Hemant; Rajeswaran, Jeevanantham; Ehrlinger, John; Blackstone, Eugene H.
2016-01-01
Atrial fibrillation (AF) is an abnormal heart rhythm characterized by rapid and irregular heart beat, with or without perceivable symptoms. In clinical practice, the electrocardiogram (ECG) is often used for diagnosis of AF. Since the AF often arrives as recurrent episodes of varying frequency and duration and only the episodes that occur at the time of ECG can be detected, the AF is often underdiagnosed when a limited number of repeated ECGs are used. In studies evaluating the efficacy of AF ablation surgery, each patient undergo multiple ECGs and the AF status at the time of ECG is recorded. The objective of this paper is to estimate the marginal proportions of patients with or without AF in a population, which are important measures of the efficacy of the treatment. The underdiagnosis problem is addressed by a three-class mixture regression model in which a patient’s probability of having no AF, paroxysmal AF, and permanent AF is modeled by auxiliary baseline covariates in a nested logistic regression. A binomial regression model is specified conditional on a subject being in the paroxysmal AF group. The model parameters are estimated by the EM algorithm. These parameters are themselves nuisance parameters for the purpose of this research, but the estimators of the marginal proportions of interest can be expressed as functions of the data and these nuisance parameters and their variances can be estimated by the sandwich method. We examine the performance of the proposed methodology in simulations and two real data applications. PMID:27983754
Intraocular straylight screening in medical testing centres for driver licence holders in Spain
Michael, Ralph; Barraquer, Rafael I.; Rodríguez, Judith; Tuñi i Picado, Josep; Jubal, Joan Serra; González Luque, Juan Carlos; van den Berg, Tom
2010-01-01
Purpose To test the performance of the C-quant straylight meter during the daily routine work in medical testing centres for driver license applicants and driver license holders in Spain. Methods Altogether 914 subjects, of which 376 younger than 35 years, 428 between 35 and 60 years and 110 over 60 years were measured with the C-quant in three medical testing centres (Barcelona, Zaragoza and Palma de Mallorca) in 2006. Technicians were instructed once and the measurements were done during the daily routine work. We recorded: age, BCVA, self-reported subjective blinding at night; and from the C-quant: straylight parameter (log s), measurement quality parameters (ESD, Q) and test duration. Results Total C-quant test duration increases slightly with age from a mean of 7 min (< 35 years) to a mean of 9 min (> 60). At first attempt, 82 % of all subjects produced reliable results (ESD < 0.12). The straylight parameter for this group was independent of ESD and ESD was independent of total test duration. The known age dependence of the straylight parameter and the weak correlation with BCVA was confirmed. The distribution of subjective blinding at night was very different between test centres. Subjects with “very strong” subjective blinding had significantly higher straylight values than subjects with “no” subjective blinding. Subjects avoiding night driving had significant higher straylight values than subjects driving at night. Conclusion The C-quant measure is reasonable fast. Good subject instruction is important to get first attempt reliable results. Self-reported subjective blinding results depend strongly on the interviewer.
Relationship between masticatory performance using a gummy jelly and masticatory movement.
Uesugi, Hanako; Shiga, Hiroshi
2017-10-01
The purpose of this study was to clarify the relationship between masticatory performance using a gummy jelly and masticatory movement. Thirty healthy males were asked to chew a gummy jelly on their habitual chewing side for 20s, and the parameters of masticatory performance and masticatory movement were calculated as follows. For evaluating the masticatory performance, the amount of glucose extraction during chewing of a gummy jelly was measured. For evaluating the masticatory movement, the movement of the mandibular incisal point was recorded using the MKG K6-I, and ten parameters of the movement path (opening distance and masticatory width), movement rhythm (opening time, closing time, occluding time, and cycle time), stability of movement (stability of path and stability of rhythm), and movement velocity (opening maximum velocity and closing maximum velocity) were calculated from 10 cycles of chewing beginning with the fifth cycle. The relationship between the amount of glucose extraction and parameters representing masticatory movement was investigated and then stepwise multiple linear regression analysis was performed. The amount of glucose extraction was associated with 7 parameters representing the masticatory movement. Stepwise multiple linear regression analysis showed that the opening distance, closing time, stability of rhythm, and closing maximum velocity were the most important factors affecting the glucose extraction. From these results it was suggested that there was a close relation between masticatory performance and masticatory movement, and that the masticatory performance could be increased by rhythmic, rapid and stable mastication with a large opening distance. Copyright © 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Sege, J.; Li, Y.; Chang, C. F.; Chen, J.; Chen, Z.; Rubin, Y.; Li, X.; Hehua, Z.; Wang, C.; Osorio-Murillo, C. A.
2015-12-01
This study will develop a numerical model to characterize the perturbation of local groundwater systems by underground tunnel construction. Tunnels and other underground spaces act as conduits that remove water from the surrounding aquifer, and may lead to drawdown of the water table. Significant declines in water table elevation can cause environmental impacts by altering root zone soil moisture and changing inflows to surface waters. Currently, it is common to use analytical solutions to estimate groundwater fluxes through tunnel walls. However, these solutions often neglect spatial and temporal heterogeneity in aquifer parameters and system stresses. Some heterogeneous parameters, such as fracture densities, can significantly affect tunnel inflows. This study will focus on numerical approaches that incorporate heterogeneity across a range of scales. Time-dependent simulations will be undertaken to compute drawdown at various stages of excavation, and to model water table recovery after low-conductivity liners are applied to the tunnel walls. This approach will assist planners in anticipating environmental impacts to local surface waters and vegetation, and in computing the amount of tunnel inflow reduction required to meet environmental targets. The authors will also focus on managing uncertainty in model parameters. For greater planning applicability, extremes of a priori parameter ranges will be explored in order to anticipate best- and worst-case scenarios. For calibration and verification purposes, the model will be applied to a completed tunnel project in Mount Mingtang, China, where tunnel inflows were recorded throughout the construction process.
Li, Liang; Mao, Huzhang; Ishwaran, Hemant; Rajeswaran, Jeevanantham; Ehrlinger, John; Blackstone, Eugene H
2017-03-01
Atrial fibrillation (AF) is an abnormal heart rhythm characterized by rapid and irregular heartbeat, with or without perceivable symptoms. In clinical practice, the electrocardiogram (ECG) is often used for diagnosis of AF. Since the AF often arrives as recurrent episodes of varying frequency and duration and only the episodes that occur at the time of ECG can be detected, the AF is often underdiagnosed when a limited number of repeated ECGs are used. In studies evaluating the efficacy of AF ablation surgery, each patient undergoes multiple ECGs and the AF status at the time of ECG is recorded. The objective of this paper is to estimate the marginal proportions of patients with or without AF in a population, which are important measures of the efficacy of the treatment. The underdiagnosis problem is addressed by a three-class mixture regression model in which a patient's probability of having no AF, paroxysmal AF, and permanent AF is modeled by auxiliary baseline covariates in a nested logistic regression. A binomial regression model is specified conditional on a subject being in the paroxysmal AF group. The model parameters are estimated by the Expectation-Maximization (EM) algorithm. These parameters are themselves nuisance parameters for the purpose of this research, but the estimators of the marginal proportions of interest can be expressed as functions of the data and these nuisance parameters and their variances can be estimated by the sandwich method. We examine the performance of the proposed methodology in simulations and two real data applications. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Administration DEPARTMENT OF JUSTICE CRIMINAL JUSTICE INFORMATION SYSTEMS General Provisions § 20.1 Purpose. It is the purpose of these regulations to assure that criminal history record information wherever it..., integrity, and security of such information and to protect individual privacy. [Order No. 2258-99, 64 FR...
The Use of Recorded Lectures in Education and the Impact on Lecture Attendance and Exam Performance
ERIC Educational Resources Information Center
Bos, Nynke; Groeneveld, Caspar; van Bruggen, Jan; Brand-Gruwel, Saskia
2016-01-01
Universities increasingly record lectures and make them available online for students. Though the technology to record these lectures is now solidly implemented and embedded in many institutions, the impact of the usage of recorded lectures on exam performance is not clear. The purpose of the current study is to address the use of recorded…
78 FR 39016 - Office of Presidential Libraries; Proposed Disposal of George H.W. Bush and Clinton...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-28
... for disaster recovery purposes, NARA is following a procedure similar to that in GRS 24 for Federal... made for emergency purposes are not record keeping media; rather, their sole purpose is to be available... backup tapes have already served that purpose and NARA has no need to conduct any further restoration...
Instrumentation to Record Evoked Potentials for Closed-Loop Control of Deep Brain Stimulation
Kent, Alexander R.; Grill, Warren M.
2012-01-01
Closed-loop deep brain stimulation (DBS) systems offer promise in relieving the clinical burden of stimulus parameter selection and improving treatment outcomes. In such a system, a feedback signal is used to adjust automatically stimulation parameters and optimize the efficacy of stimulation. We explored the feasibility of recording electrically evoked compound action potentials (ECAPs) during DBS for use as a feedback control signal. A novel instrumentation system was developed to suppress the stimulus artifact and amplify the small magnitude, short latency ECAP response during DBS with clinically relevant parameters. In vitro testing demonstrated the capabilities to increase the gain by a factor of 1,000x over a conventional amplifier without saturation, reduce distortion of mock ECAP signals, and make high fidelity recordings of mock ECAPs at latencies of only 0.5 ms following DBS pulses of 50 to 100 μs duration. Subsequently, the instrumentation was used to make in vivo recordings of ECAPs during thalamic DBS in cats, without contamination by the stimulus artifact. The signal characteristics were similar across three experiments, suggesting common neural activation patterns. The ECAP recordings enabled with this novel instrumentation may provide insight into the type and spatial extent of neural elements activated during DBS, and could serve as feedback control signals for closed-loop systems. PMID:22255894
12 CFR 360.11 - Records of failed insured depository institutions.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 12 Banks and Banking 5 2014-01-01 2014-01-01 false Records of failed insured depository... STATEMENTS OF GENERAL POLICY RESOLUTION AND RECEIVERSHIP RULES § 360.11 Records of failed insured depository institutions. (a) Definitions. For purposes of this section, the following definitions apply— (1) Failed...
26 CFR 1.6038A-3 - Record maintenance.
Code of Federal Regulations, 2011 CFR
2011-04-01
... control RC and the two corporations do not constitute a group of “controlled taxpayers” for purposes of... party does not control. Functional equivalents of the specified documents are acceptable. Record.... If, however, on audit it is determined that F does control RC, all records relevant to determining...
26 CFR 1.6038A-3 - Record maintenance.
Code of Federal Regulations, 2014 CFR
2014-04-01
... control RC and the two corporations do not constitute a group of “controlled taxpayers” for purposes of... party does not control. Functional equivalents of the specified documents are acceptable. Record.... If, however, on audit it is determined that F does control RC, all records relevant to determining...
14 CFR Section 14 - Objective Classification-Nonoperating Income and Expense
Code of Federal Regulations, 2010 CFR
2010-01-01
.... [ER-1401, 50 FR 245, Jan. 3, 1985] 81Interest on Long-term Debt and Capital Leases. (a) Record here... sheet classification purposes. 81.2Interest expense—capital leases. Record here for all capitalized... reasonably identifiable. (c) Amortization expense attributable to capital leases recorded in balance sheet...
78 FR 54945 - Privacy Act; System of Records: Protocol Records, State-33
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-06
... accounting of those U.S. government officials receiving gifts and decorations from foreign governments and to....C. 2625, 22 U.S.C. 4301 et seq. PURPOSE: The information in this system of records is an accounting... public and professional institutions possessing relevant information. SYSTEMS EXEMPTED FROM CERTAIN...
Principles of Successful Implementation of Lecture Recordings in Higher Education
ERIC Educational Resources Information Center
Ollermann, Frank; Rolf, Rüdiger; Greweling, Christian; Klaßen, André
2017-01-01
Purpose: This paper aims to describe the principles underlying the successful implementation of a lecture recording service in higher education. Design/methodology/approach: The paper qualitatively reviews the practices and experiences of several years of automated lecture recording at a medium-sized university in Germany. Findings: The paper…
28 CFR 906.2 - Third party handling of criminal history record information.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 28 Judicial Administration 2 2014-07-01 2014-07-01 false Third party handling of criminal history... of criminal history record information. (a) Except as prohibited in paragraph (b) of this section, criminal history record information obtained from the III System for noncriminal justice purposes may be...
28 CFR 906.2 - Third party handling of criminal history record information.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 28 Judicial Administration 2 2013-07-01 2013-07-01 false Third party handling of criminal history... of criminal history record information. (a) Except as prohibited in paragraph (b) of this section, criminal history record information obtained from the III System for noncriminal justice purposes may be...
28 CFR 906.2 - Third party handling of criminal history record information.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 28 Judicial Administration 2 2011-07-01 2011-07-01 false Third party handling of criminal history... of criminal history record information. (a) Except as prohibited in paragraph (b) of this section, criminal history record information obtained from the III System for noncriminal justice purposes may be...
28 CFR 906.2 - Third party handling of criminal history record information.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 28 Judicial Administration 2 2012-07-01 2012-07-01 false Third party handling of criminal history... of criminal history record information. (a) Except as prohibited in paragraph (b) of this section, criminal history record information obtained from the III System for noncriminal justice purposes may be...
22 CFR 308.4 - Disclosure of records.
Code of Federal Regulations, 2010 CFR
2010-04-01
... record for statistical research provided that such record is transmitted in a form which is not... will be used only for statistical purposes. (f) To the National Archives of the United States as a... governmental jurisdiction within the control of the United States for civil or criminal law enforcement...
Code of Federal Regulations, 2010 CFR
2010-10-01
... Officer refers to the individual designated to process requests and handle various other matters relating... finger or voice print or a photograph. Statistical Record means a record in a system of records maintained for statistical research or reporting purposes only and not used in whole or in part in making any...
28 CFR 906.2 - Third party handling of criminal history record information.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Third party handling of criminal history... of criminal history record information. (a) Except as prohibited in paragraph (b) of this section, criminal history record information obtained from the III System for noncriminal justice purposes may be...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-18
...; Submission for OMB Review; Examination of Records by Comptroller General and Contract Audit AGENCY... by comptroller general and contract audit. A request for public comments was published in the Federal... [email protected] . SUPPLEMENTARY INFORMATION: A. Purpose The Audit and Records-Negotiation clause...
Digital Data Collection and Analysis: Application for Clinical Practice
ERIC Educational Resources Information Center
Ingram, Kelly; Bunta, Ferenc; Ingram, David
2004-01-01
Technology for digital speech recording and speech analysis is now readily available for all clinicians who use a computer. This article discusses some advantages of moving from analog to digital recordings and outlines basic recording procedures. The purpose of this article is to familiarize speech-language pathologists with computerized audio…
7 CFR 3200.9 - Accountability and record keeping.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 15 2011-01-01 2011-01-01 false Accountability and record keeping. 3200.9 Section... TRANSFER OF EXCESS PERSONAL PROPERTY § 3200.9 Accountability and record keeping. USDA requires that Federal... use for a research, educational, technical, or scientific activity, or for a related purpose, within 1...
Code of Federal Regulations, 2011 CFR
2011-04-01
... individual's name or personal identifier, such as a social security number. (g) Routine use. With respect to... proper and necessary uses even if any such uses occur infrequently. (h) Statistical record. A record in a system of records maintained for statistical research or reporting purposes only and not used in whole or...
17 CFR 10.65 - Record of hearing.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 17 Commodity and Securities Exchanges 1 2010-04-01 2010-04-01 false Record of hearing. 10.65 Section 10.65 Commodity and Securities Exchanges COMMODITY FUTURES TRADING COMMISSION RULES OF PRACTICE Hearings § 10.65 Record of hearing. (a) Reporting and transcription. Hearings for the purpose of taking...
17 CFR 10.65 - Record of hearing.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 17 Commodity and Securities Exchanges 1 2011-04-01 2011-04-01 false Record of hearing. 10.65 Section 10.65 Commodity and Securities Exchanges COMMODITY FUTURES TRADING COMMISSION RULES OF PRACTICE Hearings § 10.65 Record of hearing. (a) Reporting and transcription. Hearings for the purpose of taking...
14 CFR Section 14 - Objective Classification-Nonoperating Income and Expense
Code of Federal Regulations, 2011 CFR
2011-01-01
.... [ER-1401, 50 FR 245, Jan. 3, 1985] 81Interest on Long-term Debt and Capital Leases. (a) Record here... sheet classification purposes. 81.2Interest expense—capital leases. Record here for all capitalized... reasonably identifiable. (c) Amortization expense attributable to capital leases recorded in balance sheet...
DOT National Transportation Integrated Search
1973-01-01
The purpose of the study was to define the current traffic records system of the Commonwealth so as to identify deficiencies as specifically as possible; to suggest changes to upgrade the system to meet current and projected demands at maximum effici...
5 CFR 294.107 - Places to obtain records.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Retirement; life and health insurance. Associate Director for Personnel Systems and Oversight Personnel...) Creating records. If a person seeks information from OPM in a format that does not currently exist, OPM will not ordinarily compile the information for the purpose of creating a record to respond to the...
Saturated-unsaturated flow to a well with storage in a compressible unconfined aquifer
NASA Astrophysics Data System (ADS)
Mishra, Phoolendra Kumar; Neuman, Shlomo P.
2011-05-01
Mishra and Neuman (2010) developed an analytical solution for flow to a partially penetrating well of zero radius in a compressible unconfined aquifer that allows inferring its saturated and unsaturated hydraulic properties from responses recorded in the saturated and/or unsaturated zones. Their solution accounts for horizontal as well as vertical flows in each zone. It represents unsaturated zone constitutive properties in a manner that is at once mathematically tractable and sufficiently flexible to provide much improved fits to standard constitutive models. In this paper we extend the solution of [2010] to the case of a finite diameter pumping well with storage; investigate the effects of storage in the pumping well and delayed piezometer response on drawdowns in the saturated and unsaturated zones as functions of position and time; validate our solution against numerical simulations of drawdown in a synthetic aquifer having unsaturated properties described by the [1980]- [1976] model; use our solution to analyze 11 transducer-measured drawdown records from a seven-day pumping test conducted by University of Waterloo researchers at the Canadian Forces Base Borden in Ontario, Canada; validate our parameter estimates against manually-measured drawdown records in 14 other piezometers at Borden; and compare (a) our estimates of aquifer parameters with those obtained on the basis of all these records by [2008], (b) on the basis of 11 transducer-measured drawdown records by [2007], (c) our estimates of van Genuchten-Mualem parameters with those obtained on the basis of laboratory drainage data from the site by [1992], and (d) our corresponding prediction of how effective saturation varies with elevation above the initial water table under static conditions with a profile based on water contents measured in a neutron access tube at a radial distance of about 5 m from the center of the pumping well. We also use our solution to analyze 11 transducer-measured drawdown records from a 7 day pumping test conducted by University of Waterloo researchers at the Canadian Forces Base Borden in Ontario, Canada. We validate our parameter estimates against manually measured drawdown records in 14 other piezometers at Borden. We compare our estimates of aquifer parameters with those obtained on the basis of all these records by Moench (2008) and on the basis of 11 transducer-measured drawdown records by Endres et al. (2007), and we compare our estimates of van Genuchten-Mualem parameters with those obtained on the basis of laboratory drainage data from the site by Akindunni and Gillham (1992); finally, we compare our corresponding prediction of how effective saturation varies with elevation above the initial water table under static conditions with a profile based on water contents measured in a neutron access tube at a radial distance of about 5 m from the center of the pumping well.
Wang, Duolao; Bakhai, Ameet; Arezina, Radivoj; Täubel, Jörg
2016-11-01
Electrocardiogram (ECG) variability is greatly affected by the ECG recording method. This study aims to compare Holter and standard ECG recording methods in terms of central locations and variations of ECG data. We used the ECG data from a double-blinded, placebo-controlled, randomized clinical trial and used a mixed model approach to assess the agreement between two methods in central locations and variations of eight ECG parameters (Heart Rate, PR, QRS, QT, RR, QTcB, QTcF, and QTcI intervals). A total of 34 heathy male subjects with mean age of 25.7 ± 4.78 years were randomized to receive either active drug or placebo. Digital 12-lead ECG and digital 12-lead Holter ECG recordings were performed to assess ECG variability. There are no significant differences in least square mean between the Holter and the standard method for all ECG parameters. The total variance is consistently higher for the Holter method than the standard method for all ECG parameters except for QRS. The intraclass correlation coefficient (ICC) values for the Holter method are consistently lower than those for the standard method for all ECG parameters except for QRS, in particular, the ICC for QTcF is reduced from 0.86 for the standard method to 0.67 for the Holter method. This study suggests that Holter ECGs recorded in a controlled environment are not significantly different but more variable than those from the standard method. © 2016 Wiley Periodicals, Inc.
14 CFR Appendix B to Part 135 - Airplane Flight Recorder Specifications
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Airplane Flight Recorder Specifications B Appendix B to Part 135 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION.... B Appendix B to Part 135—Airplane Flight Recorder Specifications Parameters Range Installed system 1...
14 CFR Appendix B to Part 135 - Airplane Flight Recorder Specifications
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Airplane Flight Recorder Specifications B Appendix B to Part 135 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION.... B Appendix B to Part 135—Airplane Flight Recorder Specifications Parameters Range Installed system 1...
14 CFR Appendix E to Part 91 - Airplane Flight Recorder Specifications
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 2 2013-01-01 2013-01-01 false Airplane Flight Recorder Specifications E Appendix E to Part 91 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... Appendix E to Part 91—Airplane Flight Recorder Specifications Parameters Range Installed system 1 minimum...
14 CFR Appendix E to Part 91 - Airplane Flight Recorder Specifications
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 2 2014-01-01 2014-01-01 false Airplane Flight Recorder Specifications E Appendix E to Part 91 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... Appendix E to Part 91—Airplane Flight Recorder Specifications Parameters Range Installed system 1 minimum...
14 CFR Appendix B to Part 135 - Airplane Flight Recorder Specifications
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Airplane Flight Recorder Specifications B Appendix B to Part 135 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION.... B Appendix B to Part 135—Airplane Flight Recorder Specifications Parameters Range Installed system 1...
14 CFR Appendix E to Part 91 - Airplane Flight Recorder Specifications
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 2 2011-01-01 2011-01-01 false Airplane Flight Recorder Specifications E Appendix E to Part 91 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... Appendix E to Part 91—Airplane Flight Recorder Specifications Parameters Range Installed system 1 minimum...
14 CFR Appendix B to Part 135 - Airplane Flight Recorder Specifications
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Airplane Flight Recorder Specifications B Appendix B to Part 135 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION.... B Appendix B to Part 135—Airplane Flight Recorder Specifications Parameters Range Installed system 1...
14 CFR Appendix C to Part 135 - Helicopter Flight Recorder Specifications
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Helicopter Flight Recorder Specifications C Appendix C to Part 135 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION.... C Appendix C to Part 135—Helicopter Flight Recorder Specifications Parameters Range Installed system...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 41 Public Contracts and Property Management 3 2013-07-01 2013-07-01 false Purpose. 105-60.101 Section 105-60.101 Public Contracts and Property Management Federal Property Management Regulations System... AVAILABILITY OF AGENCY RECORDS AND INFORMATIONAL MATERIALS 60.1-General Provisions § 105-60.101 Purpose. This...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 41 Public Contracts and Property Management 3 2012-01-01 2012-01-01 false Purpose. 105-60.101 Section 105-60.101 Public Contracts and Property Management Federal Property Management Regulations System... AVAILABILITY OF AGENCY RECORDS AND INFORMATIONAL MATERIALS 60.1-General Provisions § 105-60.101 Purpose. This...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 41 Public Contracts and Property Management 3 2014-01-01 2014-01-01 false Purpose. 105-60.101 Section 105-60.101 Public Contracts and Property Management Federal Property Management Regulations System... AVAILABILITY OF AGENCY RECORDS AND INFORMATIONAL MATERIALS 60.1-General Provisions § 105-60.101 Purpose. This...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false Purpose. 105-60.101 Section 105-60.101 Public Contracts and Property Management Federal Property Management Regulations System... AVAILABILITY OF AGENCY RECORDS AND INFORMATIONAL MATERIALS 60.1-General Provisions § 105-60.101 Purpose. This...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 41 Public Contracts and Property Management 3 2011-01-01 2011-01-01 false Purpose. 105-60.101 Section 105-60.101 Public Contracts and Property Management Federal Property Management Regulations System... AVAILABILITY OF AGENCY RECORDS AND INFORMATIONAL MATERIALS 60.1-General Provisions § 105-60.101 Purpose. This...
20 CFR 416.803 - Evaluation of evidence.
Code of Federal Regulations, 2010 CFR
2010-04-01
..., BLIND, AND DISABLED Determination of Age § 416.803 Evaluation of evidence. Generally, the highest.... Among the documents which may be submitted for such purpose are: school record, census record, Bible or...
21 CFR 20.64 - Records or information compiled for law enforcement purposes.
Code of Federal Regulations, 2011 CFR
2011-04-01
... AND HUMAN SERVICES GENERAL PUBLIC INFORMATION Exemptions § 20.64 Records or information compiled for... conducting a lawful national security intelligence investigation; (5) Would disclose techniques and...
Code of Federal Regulations, 2010 CFR
2010-10-01
..., or corporations. A business firm which is identified by the name of one or more persons is not an.... (l) Statistical record means a record maintained for statistical research or reporting purposes only...
1994-09-01
materials. Also, available data from drilling rates in the mining and tunneling industries (Howarth and Rowlands 1987, Somerton 1959) indicate a...selected uniform natural rock materials and several man -made rock simulants were used to obtain drilling parameter records for materials of known...Dredging Seminar, Atlantic City, NJ, May 1993. Western Dredging Association (WEDA) and Texas A&M University. Somerton , W. H. (1959). "A laboratory study of
32 CFR 320.1 - Purpose and scope.
Code of Federal Regulations, 2010 CFR
2010-07-01
... NATIONAL GEOSPATIAL-INTELLIGENCE AGENCY (NGA) PRIVACY § 320.1 Purpose and scope. (a) This part is published... whether the National Geospatial-Intelligence Agency (NGA) maintains or has disclosed a record pertaining...
32 CFR 320.1 - Purpose and scope.
Code of Federal Regulations, 2014 CFR
2014-07-01
... NATIONAL GEOSPATIAL-INTELLIGENCE AGENCY (NGA) PRIVACY § 320.1 Purpose and scope. (a) This part is published... whether the National Geospatial-Intelligence Agency (NGA) maintains or has disclosed a record pertaining...
32 CFR 320.1 - Purpose and scope.
Code of Federal Regulations, 2012 CFR
2012-07-01
... NATIONAL GEOSPATIAL-INTELLIGENCE AGENCY (NGA) PRIVACY § 320.1 Purpose and scope. (a) This part is published... whether the National Geospatial-Intelligence Agency (NGA) maintains or has disclosed a record pertaining...
28 CFR 16.30 - Purpose and scope.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Production of FBI Identification Records in Response to Written Requests by Subjects Thereof § 16.30 Purpose and scope. This subpart contains the regulations of the Federal Bureau of Investigation (FBI...
28 CFR 16.30 - Purpose and scope.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Production of FBI Identification Records in Response to Written Requests by Subjects Thereof § 16.30 Purpose and scope. This subpart contains the regulations of the Federal Bureau of Investigation (FBI...
28 CFR 16.30 - Purpose and scope.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Production of FBI Identification Records in Response to Written Requests by Subjects Thereof § 16.30 Purpose and scope. This subpart contains the regulations of the Federal Bureau of Investigation (FBI...
28 CFR 16.30 - Purpose and scope.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Production of FBI Identification Records in Response to Written Requests by Subjects Thereof § 16.30 Purpose and scope. This subpart contains the regulations of the Federal Bureau of Investigation (FBI...
28 CFR 16.30 - Purpose and scope.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Production of FBI Identification Records in Response to Written Requests by Subjects Thereof § 16.30 Purpose and scope. This subpart contains the regulations of the Federal Bureau of Investigation (FBI...
40 CFR 63.2998 - What records must I maintain?
Code of Federal Regulations, 2010 CFR
2010-07-01
...) Records of maintenance and inspections performed on the control devices. (e) If an operating parameter... which corrective actions were initiated and completed; (4) A brief description of the corrective actions...
Code of Federal Regulations, 2010 CFR
2010-10-01
... of the existence and character of the systems of records which it maintains. Such notice will include... the records contained in each system including the categories of users and the purpose of each use; (e...
4 CFR 28.63 - Closing the record.
Code of Federal Regulations, 2011 CFR
2011-01-01
... left open for such time as the administrative judge grants for that purpose. (b) Once the record is... new and material evidence has become available which was not available despite due diligence prior to...
4 CFR 28.63 - Closing the record.
Code of Federal Regulations, 2010 CFR
2010-01-01
... left open for such time as the administrative judge grants for that purpose. (b) Once the record is... new and material evidence has become available which was not available despite due diligence prior to...
Adaptive estimation of hand movement trajectory in an EEG based brain-computer interface system
NASA Astrophysics Data System (ADS)
Robinson, Neethu; Guan, Cuntai; Vinod, A. P.
2015-12-01
Objective. The various parameters that define a hand movement such as its trajectory, speed, etc, are encoded in distinct brain activities. Decoding this information from neurophysiological recordings is a less explored area of brain-computer interface (BCI) research. Applying non-invasive recordings such as electroencephalography (EEG) for decoding makes the problem more challenging, as the encoding is assumed to be deep within the brain and not easily accessible by scalp recordings. Approach. EEG based BCI systems can be developed to identify the neural features underlying movement parameters that can be further utilized to provide a detailed and well defined control command set to a BCI output device. A real-time continuous control is better suited for practical BCI systems, and can be achieved by continuous adaptive reconstruction of movement trajectory than discrete brain activity classifications. In this work, we adaptively reconstruct/estimate the parameters of two-dimensional hand movement trajectory, namely movement speed and position, from multi-channel EEG recordings. The data for analysis is collected by performing an experiment that involved center-out right-hand movement tasks in four different directions at two different speeds in random order. We estimate movement trajectory using a Kalman filter that models the relation between brain activity and recorded parameters based on a set of defined predictors. We propose a method to define these predictor variables that includes spatial, spectral and temporally localized neural information and to select optimally informative variables. Main results. The proposed method yielded correlation of (0.60 ± 0.07) between recorded and estimated data. Further, incorporating the proposed predictor subset selection, the correlation achieved is (0.57 ± 0.07, p {\\lt }0.004) with significant gain in stability of the system, as well as dramatic reduction in number of predictors (76%) for the savings of computational time. Significance. The proposed system provides a real time movement control system using EEG-BCI with control over movement speed and position. These results are higher and statistically significant compared to existing techniques in EEG based systems and thus promise the applicability of the proposed method for efficient estimation of movement parameters and for continuous motor control.
Access Control Model for Sharing Composite Electronic Health Records
NASA Astrophysics Data System (ADS)
Jin, Jing; Ahn, Gail-Joon; Covington, Michael J.; Zhang, Xinwen
The adoption of electronically formatted medical records, so called Electronic Health Records (EHRs), has become extremely important in healthcare systems to enable the exchange of medical information among stakeholders. An EHR generally consists of data with different types and sensitivity degrees which must be selectively shared based on the need-to-know principle. Security mechanisms are required to guarantee that only authorized users have access to specific portions of such critical record for legitimate purposes. In this paper, we propose a novel approach for modelling access control scheme for composite EHRs. Our model formulates the semantics and structural composition of an EHR document, from which we introduce a notion of authorized zones of the composite EHR at different granularity levels, taking into consideration of several important criteria such as data types, intended purposes and information sensitivities.
Development of Poincare Software to Predict Arrythmias
NASA Technical Reports Server (NTRS)
Maaliki, Samer
2003-01-01
The most distressing types of heart malfunction occur because of an abnormal rhythm of the heart. Cardiac arrythmias can be caused by abnormal rhythmicity of the pacemaker, electrolyte disturbances, blockage of the transmission of the electric impulse through the heart, and other abnormalities. There is strong evidence that space flight is associated with decreased cardiac electrical stability that may pose a life threatening risk to astronauts. For example, during the Skylab missions, a crewmember had a five beat run of ventricular tachycardia during lower body negative pressure. Also, analysis of nine 24-hour Holter monitor recordings obtained during long term spaceflight on Mir revealed one 14-beat run of ventricular tachycardia. A Mir cosmonaut was replaced in 1986 because of cardiac dysrhythmias. Most recently, in July of 1997, a Mir commander was unable to participate in the Spektr module repair due to complaints of an irregular heart rhythm. Despite these examples, possible mechanisms of arrhythmias and countermeasure strategies have barely been addressed. The Poincare method has been proposed as a technique that might potentially predict life-threatening arrhythmias before they occur. According to this method, each RR interval obtained from an EKG recording is plotted sequentially vs. the previous RR interval. Several studies using the method have demonstrated a strong correlation between the shape of the Poincare plot and ventricular arrhythmia. Our purpose was to develop an automated software program that detects the R peaks from an EKG recording while simultaneously displaying the Poincare plot and other related parameters.
Repeated Earthquakes in the Vrancea Subcrustal Source and Source Scaling
NASA Astrophysics Data System (ADS)
Popescu, Emilia; Otilia Placinta, Anica; Borleasnu, Felix; Radulian, Mircea
2017-12-01
The Vrancea seismic nest, located at the South-Eastern Carpathians Arc bend, in Romania, is a well-confined cluster of seismicity at intermediate depth (60 - 180 km). During the last 100 years four major shocks were recorded in the lithosphere body descending almost vertically beneath the Vrancea region: 10 November 1940 (Mw 7.7, depth 150 km), 4 March 1977 (Mw 7.4, depth 94 km), 30 August 1986 (Mw 7.1, depth 131 km) and a double shock on 30 and 31 May 1990 (Mw 6.9, depth 91 km and Mw 6.4, depth 87 km, respectively). The probability of repeated earthquakes in the Vrancea seismogenic volume is relatively large taking into account the high density of foci. The purpose of the present paper is to investigate source parameters and clustering properties for the repetitive earthquakes (located close each other) recorded in the Vrancea seismogenic subcrustal region. To this aim, we selected a set of earthquakes as templates for different co-located groups of events covering the entire depth range of active seismicity. For the identified clusters of repetitive earthquakes, we applied spectral ratios technique and empirical Green’s function deconvolution, in order to constrain as much as possible source parameters. Seismicity patterns of repeated earthquakes in space, time and size are investigated in order to detect potential interconnections with larger events. Specific scaling properties are analyzed as well. The present analysis represents a first attempt to provide a strategy for detecting and monitoring possible interconnections between different nodes of seismic activity and their role in modelling tectonic processes responsible for generating the major earthquakes in the Vrancea subcrustal seismogenic source.
Thermo-mechanical simulation of liquid-supported stretch blow molding
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zimmer, J.; Stommel, M.
2015-05-22
Stretch blow molding is the well-established plastics forming method to produce Polyehtylene therephtalate (PET) bottles. An injection molded preform is heated up above the PET glass transition temperature (Tg∼85°C) and subsequently inflated by pressurized air into a closed cavity. In the follow-up filling process, the resulting bottle is filled with the final product. A recently developed modification of the process combines the blowing and filling stages by directly using the final liquid product to inflate the preform. In a previously published paper, a mechanical simulation and successful evaluation of this liquid-driven stretch blow molding process was presented. In this way,more » a realistic process parameter dependent simulation of the preform deformation throughout the forming process was enabled, whereas the preform temperature evolution during forming was neglected. However, the formability of the preform is highly reduced when the temperature sinks below Tg during forming. Experimental investigations show temperature-induced failure cases due to the fast heat transfer between hot preform and cold liquid. Therefore, in this paper, a process dependent simulation of the temperature evolution during processing to avoid preform failure is presented. For this purpose, the previously developed mechanical model is used to extract the time dependent thickness evolution. This information serves as input for the heat transfer simulation. The required material parameters are calibrated from preform cooling experiments recorded with an infrared-camera. Furthermore, the high deformation ratios during processing lead to strain induced crystallization. This exothermal reaction is included into the simulation by extracting data from preform measurements at different stages of deformation via Differential Scanning Calorimetry (DSC). Finally, the thermal simulation model is evaluated by free forming experiments, recorded by a high-speed infrared camera.« less
NASA Astrophysics Data System (ADS)
Amodeo, Tanguy; Dutouquet, Christophe; Le Bihan, Olivier; Attoui, Michel; Frejafon, Emeric
2009-10-01
Laser-Induced Breakdown Spectroscopy has been employed to detect sodium chloride and metallic particles with sizes ranging from 40 nm up to 1 µm produced by two different particle generators. The Laser-Induced Breakdown Spectroscopy technique combined with a Scanning Mobility Particle Sizer was evaluated as a potential candidate for workplace surveillance in industries producing nanoparticle-based materials. Though research is still currently under way to secure nanoparticle production processes, the risk of accidental release is not to be neglected. Consequently, there is an urgent need for the manufacturers to have at their command a tool enabling leak detection in-situ and in real time so as to protect workers from potential exposure. In this context, experiments dedicated to laser-induced plasma particle interaction were performed. To begin with, spectral images of the laser-induced plasma vaporizing particles were recorded to visualize the spatio-temporal evolution of the atomized matter and to infer the best recording parameters for Laser-Induced Breakdown Spectroscopy analytical purposes, taking into account our experimental set-up specificity. Then, on this basis, time-resolved spectroscopic measurements were performed to make a first assumption of the Laser-Induced Breakdown Spectroscopy potentialities. Particle size dependency on the LIBS signal was examined. Repeatability and limits of detection were assessed and discussed. All the experiments carried out with low particle concentrations point out the high time delays corresponding to the Laser-Induced Breakdown Spectroscopy signal emergence. Plasma temperature temporal evolution was found to be a key parameter to explain this peculiarity inherent to laser/plasma/particle interaction.
The antioxidant and anti-inflammatory efficiency of hyaluronic acid after third molar extraction.
Gocmen, Gokhan; Gonul, Onur; Oktay, Nihal Sehkar; Yarat, Aysen; Goker, Kamil
2015-09-01
Hyaluronic acid (HA) has a number of clinical applications in current practice. Therefore, correlation of HA with free radicals and inflammatory cells is clinically important. The purpose of this study is to measure the efficacy of high molecular weight HA on the oxidative stress of oral wounds (glutathione (GSH) and lipid peroxidation (LPO) levels), the inflammatory reaction (leucocytes, collagen and angiogenesis content), pain (visual analogue scale (VAS) records) and trismus (maximum interincisal opening (MIO) records) after third molar (M3) extraction. 40 patients were included in this study. 0.2 ml 0.8% HA was applied immediately after surgery within the HA group (n = 20). Nothing was applied to the control group (n = 20). The primary outcome variables were the changes in the inflammatory reaction (leucocyte, angiogenesis and collagen content), oxidative stress (GSH, LPO) and clinical parameters (VAS, MIO). Results were compared immediately after extraction (T0) and 1 week after surgery (T1). Bivariate analyses were used to assess the differences between the HA and control groups for each study variable. There was a statistically significant difference of leucocyte infiltration and angiogenesis between the groups at T1. The HA group showed less leucocyte infiltration and more angiogenesis than the control group. There was no statistically significant difference in oxidative stress, VAS or MIO levels between the groups. Our results confirm the hypothesis that HA has an anti-inflammatory effect following M3 extraction. However, the oxidative stress levels and clinical outcomes were similar after one week. Further studies examining these parameters at different times are necessary. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Influence of denture adhesives on occlusion and disocclusion times.
Abdelnabi, Mohamed Hussein; Swelem, Amal Ali; Al-Dharrab, Ayman A
2016-03-01
The effectiveness of adhesives in enhancing several functional aspects of complete denture performance has been well established. The direct influence of adhesives on occlusal contact simultaneity has not yet been investigated. The purpose of this crossover clinical trial was to evaluate quantitatively the influence of adhesives on occlusal balance by recording timed occlusal contacts; namely occlusion time (OT) and disocclusion time during right (DT-right) and left (DT-left) excursions by using computerized occlusal analysis. A crossover clinical trial was adopted. Assessments were carried out while participants (n=49) wore their dentures first without then with adhesives. Computerized occlusal analysis using the T-Scan III system was conducted to perform baseline computer-guided occlusal adjustment for conventionally fabricated dentures. Retention and stability assessment using the modified Kapur index and recording of OT and DT-right and DT-left values using the T-Scan III were subsequently carried out for all dentures, first without adhesives and then after application of adhesive. All T-Scan procedures were carried out by the same clinician. Wilcoxon signed-rank test was used to analyze the Kapur index scores and occlusal parameters (α=.05). Stability and retention of conventional dentures ranged initially from good to very good. However, adhesive application resulted in significant improvement (P<.001) in stability and retention and a significant decrease in duration of all occlusal parameters (OT [P=.003], DT-right [P=.003], and DT-left [P=.008]). Adhesives significantly decreased OT and DT durations in initially well-fitting complete dentures with fairly well balanced occlusion, and further enhanced denture stability and occlusal contact simultaneity. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Mittal, Yogesh; Varghese, K George; Mohan, S; Jayakumar, N; Chhag, Somil
2016-03-01
Three dimensional titanium plating system was developed by Farmand in 1995 to meet the requirements of semi rigid fixation with lesser complication. The purpose of this in vivo prospective study was to evaluate and compare the clinical effectiveness of three dimensional and two dimensional Titanium miniplates for open reduction and fixation of mandibular parasymphysis fracture. Thirty patients with non-comminuted mandibular parasymphysis fractures were divided randomly into two equal groups and were treated with 2 mm 3D and 2D miniplate system respectively. All patients were systematically monitored at 1st, 2nd, 3rd, 6th week, 3rd and 6th month postoperatively. The outcome parameters recorded were severity of pain, infection, mobility, occlusion derangement, paresthesia and implant failure. The data so collected was analyzed using independent t test and Chi square test (α = .05). The results showed that one patient in each group had post-operative infection, occlusion derangement and mobility (p > .05). In Group A, one patient had paresthesia while in Group B, two patients had paresthesia (p > .05). None of the patients in both the groups had implant failure. There was no statistically significant difference between 3D and 2D miniplate system in all the recorded parameters at all the follow-ups (p > .05). 3D miniplates were found to be better than 2D miniplates in terms of cost, ease of surgery and operative time. However, 3D miniplates were unfavorable for cases where fracture line was oblique and in close proximity to mental foramen, where they were difficult to adapt and more chances for tooth-root damage and inadvertent injury to the mental nerve due to traction.
Morimoto, Takeshi; Kanda, Hiroyuki; Miyoshi, Tomomitsu; Hirohara, Yoko; Mihashi, Toshifumi; Kitaguchi, Yoshiyuki; Nishida, Kohji; Fujikado, Takashi
2014-01-01
Transcorneal electrical stimulation (TES) activates retinal neurons leading to visual sensations. How the retinal cells are activated by TES has not been definitively determined. Investigating the reflectance changes of the retina is an established technique and has been used to determine the mechanism of retinal activation. The purpose of this study was to evaluate the reflectance changes elicited by TES in cat eyes. Eight eyes of Eight cats were studied under general anesthesia. Biphasic electrical pulses were delivered transcornealy. The fundus images observed with near-infrared light (800-880 nm) were recorded every 25 ms for 26 s. To improve the signal-to-noise ratio, the images of 10 consecutive recordings were averaged. Two-dimensional topographic maps of the reflective changes were constructed by subtracting images before from those after the TES. The effects of different stimulus parameters, e.g., current intensity, pulse duration, frequency, and stimulus duration, on the reflective changes were studied. Our results showed that after TES, the reflective changes appeared on the retinal vessels and optic disc. The intensity of reflectance changes increased as the current intensity, pulse duration, and stimulation duration increased (P<0.05 for all). The maximum intensity of the reflective change was obtained when the stimulus frequency was 20 Hz. The time course of the reflectance changes was also altered by the stimulation parameters. The response started earlier and returned to the baseline later with higher current intensities, longer pulse durations, but the time of the peak of the response was not changed. These results showed that the reflective changes were due to the activation of retinal neurons by TES and might involve the vascular changes induced by an activation of the retinal neurons.
Vanderick, S; Troch, T; Gillon, A; Glorieux, G; Gengler, N
2014-12-01
Calving ease scores from Holstein dairy cattle in the Walloon Region of Belgium were analysed using univariate linear and threshold animal models. Variance components and derived genetic parameters were estimated from a data set including 33,155 calving records. Included in the models were season, herd and sex of calf × age of dam classes × group of calvings interaction as fixed effects, herd × year of calving, maternal permanent environment and animal direct and maternal additive genetic as random effects. Models were fitted with the genetic correlation between direct and maternal additive genetic effects either estimated or constrained to zero. Direct heritability for calving ease was approximately 8% with linear models and approximately 12% with threshold models. Maternal heritabilities were approximately 2 and 4%, respectively. Genetic correlation between direct and maternal additive effects was found to be not significantly different from zero. Models were compared in terms of goodness of fit and predictive ability. Criteria of comparison such as mean squared error, correlation between observed and predicted calving ease scores as well as between estimated breeding values were estimated from 85,118 calving records. The results provided few differences between linear and threshold models even though correlations between estimated breeding values from subsets of data for sires with progeny from linear model were 17 and 23% greater for direct and maternal genetic effects, respectively, than from threshold model. For the purpose of genetic evaluation for calving ease in Walloon Holstein dairy cattle, the linear animal model without covariance between direct and maternal additive effects was found to be the best choice. © 2014 Blackwell Verlag GmbH.
ERIC Educational Resources Information Center
Can, Ibrahim
2018-01-01
The purpose of this study was to investigate the relationship between sprint and jump performance with velocity parameters in the loaded-squat jump exercise (SQ[subscript Loaded]). In accordance with this purpose, a total of 13 athletes competing in martial sports have participated in this study voluntarily. In this study, sprint tests, vertical…
7 CFR 1.1 - Purpose and scope.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 1 2010-01-01 2010-01-01 false Purpose and scope. 1.1 Section 1.1 Agriculture Office of the Secretary of Agriculture ADMINISTRATIVE REGULATIONS Official Records § 1.1 Purpose and scope... process. This subpart also serves as the implementing regulations (referred to in § 1.3, “Agency...