Sample records for recording system ears

  1. Physiological artifacts in scalp EEG and ear-EEG.

    PubMed

    Kappel, Simon L; Looney, David; Mandic, Danilo P; Kidmose, Preben

    2017-08-11

    A problem inherent to recording EEG is the interference arising from noise and artifacts. While in a laboratory environment, artifacts and interference can, to a large extent, be avoided or controlled, in real-life scenarios this is a challenge. Ear-EEG is a concept where EEG is acquired from electrodes in the ear. We present a characterization of physiological artifacts generated in a controlled environment for nine subjects. The influence of the artifacts was quantified in terms of the signal-to-noise ratio (SNR) deterioration of the auditory steady-state response. Alpha band modulation was also studied in an open/closed eyes paradigm. Artifacts related to jaw muscle contractions were present all over the scalp and in the ear, with the highest SNR deteriorations in the gamma band. The SNR deterioration for jaw artifacts were in general higher in the ear compared to the scalp. Whereas eye-blinking did not influence the SNR in the ear, it was significant for all groups of scalps electrodes in the delta and theta bands. Eye movements resulted in statistical significant SNR deterioration in both frontal, temporal and ear electrodes. Recordings of alpha band modulation showed increased power and coherence of the EEG for ear and scalp electrodes in the closed-eyes periods. Ear-EEG is a method developed for unobtrusive and discreet recording over long periods of time and in real-life environments. This study investigated the influence of the most important types of physiological artifacts, and demonstrated that spontaneous activity, in terms of alpha band oscillations, could be recorded from the ear-EEG platform. In its present form ear-EEG was more prone to jaw related artifacts and less prone to eye-blinking artifacts compared to state-of-the-art scalp based systems.

  2. Comparison between Scalp EEG and Behind-the-Ear EEG for Development of a Wearable Seizure Detection System for Patients with Focal Epilepsy

    PubMed Central

    Gu, Ying; Cleeren, Evy; Dan, Jonathan; Claes, Kasper; Hunyadi, Borbála

    2017-01-01

    A wearable electroencephalogram (EEG) device for continuous monitoring of patients suffering from epilepsy would provide valuable information for the management of the disease. Currently no EEG setup is small and unobtrusive enough to be used in daily life. Recording behind the ear could prove to be a solution to a wearable EEG setup. This article examines the feasibility of recording epileptic EEG from behind the ear. It is achieved by comparison with scalp EEG recordings. Traditional scalp EEG and behind-the-ear EEG were simultaneously acquired from 12 patients with temporal, parietal, or occipital lobe epilepsy. Behind-the-ear EEG consisted of cross-head channels and unilateral channels. The analysis on Electrooculography (EOG) artifacts resulting from eye blinking showed that EOG artifacts were absent on cross-head channels and had significantly small amplitudes on unilateral channels. Temporal waveform and frequency content during seizures from behind-the-ear EEG visually resembled that from scalp EEG. Further, coherence analysis confirmed that behind-the-ear EEG acquired meaningful epileptic discharges similarly to scalp EEG. Moreover, automatic seizure detection based on support vector machine (SVM) showed that comparable seizure detection performance can be achieved using these two recordings. With scalp EEG, detection had a median sensitivity of 100% and a false detection rate of 1.14 per hour, while, with behind-the-ear EEG, it had a median sensitivity of 94.5% and a false detection rate of 0.52 per hour. These findings demonstrate the feasibility of detecting seizures from EEG recordings behind the ear for patients with focal epilepsy. PMID:29295522

  3. Meniere's Disease

    MedlinePlus

    ... are recorded as warm and cool water or air are gently introduced into each ear canal. Since the eyes and ears work in coordination through the nervous system, measurement of eye movements can be used to test ...

  4. Systems and methods for biometric identification using the acoustic properties of the ear canal

    DOEpatents

    Bouchard, Ann Marie; Osbourn, Gordon Cecil

    1998-01-01

    The present invention teaches systems and methods for verifying or recognizing a person's identity based on measurements of the acoustic response of the individual's ear canal. The system comprises an acoustic emission device, which emits an acoustic source signal s(t), designated by a computer, into the ear canal of an individual, and an acoustic response detection device, which detects the acoustic response signal f(t). A computer digitizes the response (detected) signal f(t) and stores the data. Computer-implemented algorithms analyze the response signal f(t) to produce ear-canal feature data. The ear-canal feature data obtained during enrollment is stored on the computer, or some other recording medium, to compare the enrollment data with ear-canal feature data produced in a subsequent access attempt, to determine if the individual has previously been enrolled. The system can also be adapted for remote access applications.

  5. Systems and methods for biometric identification using the acoustic properties of the ear canal

    DOEpatents

    Bouchard, A.M.; Osbourn, G.C.

    1998-07-28

    The present invention teaches systems and methods for verifying or recognizing a person`s identity based on measurements of the acoustic response of the individual`s ear canal. The system comprises an acoustic emission device, which emits an acoustic source signal s(t), designated by a computer, into the ear canal of an individual, and an acoustic response detection device, which detects the acoustic response signal f(t). A computer digitizes the response (detected) signal f(t) and stores the data. Computer-implemented algorithms analyze the response signal f(t) to produce ear-canal feature data. The ear-canal feature data obtained during enrollment is stored on the computer, or some other recording medium, to compare the enrollment data with ear-canal feature data produced in a subsequent access attempt, to determine if the individual has previously been enrolled. The system can also be adapted for remote access applications. 5 figs.

  6. [Effects of electromagnetic fields emitted by cellular phone on auditory and vestibular labyrinth].

    PubMed

    Sievert, U; Eggert, S; Goltz, S; Pau, H W

    2007-04-01

    It is the subject of this study to investigate the biological effect of the HF radiation produced by the Global System for Mobile Communications-( GSM)-mobile phone on the inner ear with its sensors of the vestibular and auditive systems. Thermographic investigations made on various model materials and on the human temporal bone should show whether mobile phone does induce any increases of temperature which would lead to a relevant stimulus for the auditive and vestibular system or not. We carried out video-nystagmographic recordings of 13 subjects, brainstem electric response audiometry of 24 ears, and recordings of distorsion products of otoacoustic emissions of 20 ears. All tests were made with and without a mobile phone in use. The data was then analyzed for variation patterns in the functional parameters of the hearing and balance system that are subject to the (non)existence of electromagnetic radiation from the mobile phone. The thermographic investigations suggest that the mobile phone does not induce any increases of temperature which would lead to a relevant stimulus for the auditive and vestibular system. Video-nystagmographic recordings under field effect do not furnish any indication of vestibular reactions generated by field effects. Compared with the recording without field, the brainstem electric response audiometry under field effect did not reveal any changes of the parameters investigated, i. e. absolute latency of the peaks I, III, V and the interpeak latency between the peaks I and V. The distorsion products of otoacoustic emissions do not indicate, comparing the three measuring situations, i. e. before field effect, pulsed field and continuous field, any possible impacts of the HF field on the spectrum or levels of emissions for none of the probands. The investigations made show that the electromagnetic fields generated in using the mobile phone do not have an effect on the inner ear and auditive system to the colliculus inferior in the brainstem and on the vestibular receptors in the inner ear and the vestibular system.

  7. Contralateral ear occlusion for improving the reliability of otoacoustic emission screening tests.

    PubMed

    Papsin, Emily; Harrison, Adrienne L; Carraro, Mattia; Harrison, Robert V

    2014-01-01

    Newborn hearing screening is an established healthcare standard in many countries and testing is feasible using otoacoustic emission (OAE) recording. It is well documented that OAEs can be suppressed by acoustic stimulation of the ear contralateral to the test ear. In clinical otoacoustic emission testing carried out in a sound attenuating booth, ambient noise levels are low such that the efferent system is not activated. However in newborn hearing screening, OAEs are often recorded in hospital or clinic environments, where ambient noise levels can be 60-70 dB SPL. Thus, results in the test ear can be influenced by ambient noise stimulating the opposite ear. Surprisingly, in hearing screening protocols there are no recommendations for avoiding contralateral suppression, that is, protecting the opposite ear from noise by blocking the ear canal. In the present study we have compared transient evoked and distortion product OAEs measured with and without contralateral ear plugging, in environmental settings with ambient noise levels <25 dB SPL, 45 dB SPL, and 55 dB SPL. We found out that without contralateral ear occlusion, ambient noise levels above 55 dB SPL can significantly attenuate OAE signals. We strongly suggest contralateral ear occlusion in OAE based hearing screening in noisy environments.

  8. Ability to monitor driving under the influence of marijuana among non-fatal motor-vehicle crashes: An evaluation of the Colorado electronic accident reporting system.

    PubMed

    Peterson, Alexis B; Sauber-Schatz, Erin K; Mack, Karin A

    2018-06-01

    As more states legalize medical/recreational marijuana use, it is important to determine if state motor-vehicle surveillance systems can effectively monitor and track driving under the influence (DUI) of marijuana. This study assessed Colorado's Department of Revenue motor-vehicle crash data system, Electronic Accident Reporting System (EARS), to monitor non-fatal crashes involving driving under the influence (DUI) of marijuana. Centers for Disease Control and Prevention guidelines on surveillance system evaluation were used to assess EARS' usefulness, flexibility, timeliness, simplicity, acceptability, and data quality. We assessed system components, interviewed key stakeholders, and analyzed completeness of Colorado statewide 2014 motor-vehicle crash records. EARS contains timely and complete data, but does not effectively monitor non-fatal motor-vehicle crashes related to DUI of marijuana. Information on biological sample type collected from drivers and toxicology results were not recorded into EARS; however, EARS is a flexible system that can incorporate new data without increasing surveillance system burden. States, including Colorado, could consider standardization of drug testing and mandatory reporting policies for drivers involved in motor-vehicle crashes and proactively address the narrow window of time for sample collection to improve DUI of marijuana surveillance. Practical applications: The evaluation of state motor-vehicle crash systems' ability to capture crashes involving drug impaired driving (DUID) is a critical first step for identifying frequency and risk factors for crashes related to DUID. Published by Elsevier Ltd.

  9. Identifying auditory attention with ear-EEG: cEEGrid versus high-density cap-EEG comparison

    NASA Astrophysics Data System (ADS)

    Bleichner, Martin G.; Mirkovic, Bojana; Debener, Stefan

    2016-12-01

    Objective. This study presents a direct comparison of a classical EEG cap setup with a new around-the-ear electrode array (cEEGrid) to gain a better understanding of the potential of ear-centered EEG. Approach. Concurrent EEG was recorded from a classical scalp EEG cap and two cEEGrids that were placed around the left and the right ear. Twenty participants performed a spatial auditory attention task in which three sound streams were presented simultaneously. The sound streams were three seconds long and differed in the direction of origin (front, left, right) and the number of beats (3, 4, 5 respectively), as well as the timbre and pitch. The participants had to attend to either the left or the right sound stream. Main results. We found clear attention modulated ERP effects reflecting the attended sound stream for both electrode setups, which agreed in morphology and effect size. A single-trial template matching classification showed that the direction of attention could be decoded significantly above chance (50%) for at least 16 out of 20 participants for both systems. The comparably high classification results of the single trial analysis underline the quality of the signal recorded with the cEEGrids. Significance. These findings are further evidence for the feasibility of around the-ear EEG recordings and demonstrate that well described ERPs can be measured. We conclude that concealed behind-the-ear EEG recordings can be an alternative to classical cap EEG acquisition for auditory attention monitoring.

  10. Identifying auditory attention with ear-EEG: cEEGrid versus high-density cap-EEG comparison.

    PubMed

    Bleichner, Martin G; Mirkovic, Bojana; Debener, Stefan

    2016-12-01

    This study presents a direct comparison of a classical EEG cap setup with a new around-the-ear electrode array (cEEGrid) to gain a better understanding of the potential of ear-centered EEG. Concurrent EEG was recorded from a classical scalp EEG cap and two cEEGrids that were placed around the left and the right ear. Twenty participants performed a spatial auditory attention task in which three sound streams were presented simultaneously. The sound streams were three seconds long and differed in the direction of origin (front, left, right) and the number of beats (3, 4, 5 respectively), as well as the timbre and pitch. The participants had to attend to either the left or the right sound stream. We found clear attention modulated ERP effects reflecting the attended sound stream for both electrode setups, which agreed in morphology and effect size. A single-trial template matching classification showed that the direction of attention could be decoded significantly above chance (50%) for at least 16 out of 20 participants for both systems. The comparably high classification results of the single trial analysis underline the quality of the signal recorded with the cEEGrids. These findings are further evidence for the feasibility of around the-ear EEG recordings and demonstrate that well described ERPs can be measured. We conclude that concealed behind-the-ear EEG recordings can be an alternative to classical cap EEG acquisition for auditory attention monitoring.

  11. Analysis of Saccular Function With Vestibular Evoked Myogenic Potential Test in Meniere's Disease.

    PubMed

    Dabiri, Sasan; Yazdani, Nasrin; Esfahani, Mahdis; Tari, Niloufar; Adil, Susan; Mahvi, Zahra; Rezazadeh, Nima

    2017-02-01

    Meniere's disease is the disorder of inner ear characterized by vertigo, tinnitus and sensorineural hearing loss. The vestibular evoked myogenic potential (VEMP) test could be useful in the analysis of saccular function, and diagnosis of Meniere's disease. In this study, we've analyzed the saccular function, using VEMP test in different groups of Meniere's disease. Patients were categorized as possible, probable or definite Meniere's disease groups according to the guideline of American Academy of Otolaryngology-Head and Neck Surgery. The exclusion criteria were neuromuscular system diseases, diseases of central nervous system, inner ear disorders, conductive hearing loss, a history of ototoxic drug consumption, being a drug abuser and a positive history of inner ear surgery or manipulations. The VEMP test is the recording of positive and negative waves from sternocleidomastoid muscle that is made by an auditory click to the ear. From the total of 100 patients, the waves of VEMP test was seen in 59 patients which 19 patients had abnormal amplitude, and latency and 40 patients were with normally recorded waves. There was a significant relationship between the severity of hearing loss and a VEMP test without any recorded waves. Most of the cases with 'no wave recorded' VEMP test, were patients with severe hearing loss. However, there wasn't any relation between the pattern of hearing loss and 'no wave recorded' VEMP test. VEMP test could be a valuable diagnostic clue especially in patients with definite Meniere's disease.

  12. 15 CFR 752.15 - Export clearance.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... System (AES) record. The SED or AES record covering an export made under an SCL must be prepared in... EAR. (1) Item descriptions. Item descriptions on the SED or AES record must indicate specifically the... each shipment on the respective SED or AES record. (3) SCL number. The SED or AES record must include...

  13. Computational Modeling of Blast Wave Transmission Through Human Ear.

    PubMed

    Leckness, Kegan; Nakmali, Don; Gan, Rong Z

    2018-03-01

    Hearing loss has become the most common disability among veterans. Understanding how blast waves propagate through the human ear is a necessary step in the development of effective hearing protection devices (HPDs). This article presents the first 3D finite element (FE) model of the human ear to simulate blast wave transmission through the ear. The 3D FE model of the human ear consisting of the ear canal, tympanic membrane, ossicular chain, and middle ear cavity was imported into ANSYS Workbench for coupled fluid-structure interaction analysis in the time domain. Blast pressure waveforms recorded external to the ear in human cadaver temporal bone tests were applied at the entrance of the ear canal in the model. The pressure waveforms near the tympanic membrane (TM) in the canal (P1) and behind the TM in the middle ear cavity (P2) were calculated. The model-predicted results were then compared with measured P1 and P2 waveforms recorded in human cadaver ears during blast tests. Results show that the model-derived P1 waveforms were in an agreement with the experimentally recorded waveforms with statistic Kurtosis analysis. The FE model will be used for the evaluation of HPDs in future studies.

  14. The Electronically Activated Recorder (EAR): A Method for the Naturalistic Observation of Daily Social Behavior

    PubMed Central

    Mehl, Matthias R.

    2016-01-01

    This article reviews the Electronically Activated Recorder or EAR as an ambulatory ecological momentary assessment tool for the real-world observation of daily behavior. Technically, the EAR is an audio recorder that intermittently records snippets of ambient sounds while participants go about their lives. Conceptually, it is a naturalistic observation method that yields an acoustic log of a person’s day as it unfolds. The power of the EAR lies in unobtrusively collecting authentic real-life observational data. In preserving a high degree of naturalism at the level of the raw recordings, it resembles ethnographic methods; through its sampling and coding, it enables larger empirical studies. The article provides an overview of the EAR method, reviews its validity, utility, and limitations, and discusses it in the context of current developments in ambulatory assessment, specifically the emerging field of mobile sensing. PMID:28529411

  15. The Electronically Activated Recorder (EAR): A Method for the Naturalistic Observation of Daily Social Behavior.

    PubMed

    Mehl, Matthias R

    2017-04-01

    This article reviews the Electronically Activated Recorder or EAR as an ambulatory ecological momentary assessment tool for the real-world observation of daily behavior. Technically, the EAR is an audio recorder that intermittently records snippets of ambient sounds while participants go about their lives. Conceptually, it is a naturalistic observation method that yields an acoustic log of a person's day as it unfolds. The power of the EAR lies in unobtrusively collecting authentic real-life observational data. In preserving a high degree of naturalism at the level of the raw recordings, it resembles ethnographic methods; through its sampling and coding, it enables larger empirical studies. The article provides an overview of the EAR method, reviews its validity, utility, and limitations, and discusses it in the context of current developments in ambulatory assessment, specifically the emerging field of mobile sensing.

  16. Wireless behind-the-ear EEG recording device with wireless interface to a mobile device (iPhone/iPod touch).

    PubMed

    Do Valle, Bruno G; Cash, Sydney S; Sodini, Charlie G

    2014-01-01

    EEG remains the mainstay test for the diagnosis and treatment of patients with epilepsy. Unfortunately, ambulatory EEG systems are far from ideal for patients that have infrequent seizures. The systems only last up to 3 days and if a seizure is not captured during the recordings, the doctor cannot give a definite diagnosis of the patient's condition. The ambulatory systems also suffers from being too bulky and posing some constraints on the patient, such as not being able to shower during the recordings. This paper presents a novel behind-the-ear EEG recording device that uses an iPhone or iPod Touch to continuously upload the patient's data to a secure server. This device not only gives the doctors access to the EEG data in real time but it can be easily removed and re-applied by the patient at any time, thus reducing the interference with quality of life.

  17. Correlational Study of Diabetic Retinopathy and Hearing Loss.

    PubMed

    Ooley, Caroline; Jun, Weon; Le, Kim; Kim, Allen; Rock, Nathan; Cardenal, Molly; Kline, Rebecca; Aldrich, Drew; Hayes, John

    2017-03-01

    Our research goal was to complete a retrospective chart review to determine if there is a correlation between the level of diabetic retinopathy and diabetic neurosensory hearing loss. A retrospective analysis of 175 Department of Veterans Affairs Computerized Patient Record System charts was completed at the VA Portland Health Care System. Subjects were classified by degree of diabetic retinopathy as follows: no diabetic retinopathy (n = 80), mild nonproliferative diabetic retinopathy (n = 51), moderate nonproliferative diabetic retinopathy (n = 25), and combined severe nonproliferative diabetic retinopathy and proliferative diabetic retinopathy (PDR) (n = 17). Degree of sensorineural hearing was collected for each ear. Additionally, measures of diabetic control, including hemoglobin A1C, and creatinine, were recorded. After controlling for diabetic control, as measured by HbA1C and creatinine, level of diabetic retinopathy was significantly associated with hearing loss severity in both ears (right ear, P = .018 and left ear, P = .007). When adjusted to include diabetes control, the severity of diabetic retinopathy showed a correlation with degree of hearing loss at most levels. Because of this association, recommendation for hearing evaluations may be considered for those with mild, moderate, or severe nonproliferative or proliferative diabetic retinopathy.

  18. Characteristics of the swallowing sounds recorded in the ear, nose and on trachea.

    PubMed

    Sarraf-Shirazi, Samaneh; Baril, Jonathan-F; Moussavi, Zahra

    2012-08-01

    The various malfunctions and difficulties of the swallowing mechanism necessitate various diagnostic techniques to address those problems. Swallowing sounds recorded from the trachea have been suggested as a noninvasive method of swallowing assessment. However, acquiring signals from the trachea can be difficult for those with loose skin. The objective of this pilot study was to explore the viability of using the ear and nose as alternative recording locations for recording swallowing sounds. We recorded the swallowing and breathing sounds of five healthy young individuals from the ear, nose and trachea, simultaneously. We computed time-frequency features and compared them for the different locations of recording. The features included the peak and the maximum frequencies of the power spectrum density, average power at different frequency bands and the wavelet coefficients. The average power calculated over the 4 octave bands between 150 and 2,400 Hz showed a consistent trend with less than 20 dB difference for the breath sounds of all the recording locations. Thus, analyzing breath sounds recorded from the ear and nose for the purpose of aspiration detection would give similar results to those from tracheal recordings; thus, ear and nose recording may be a viable alternative when tracheal recording is not possible.

  19. Ear-EEG detects ictal and interictal abnormalities in focal and generalized epilepsy - A comparison with scalp EEG monitoring.

    PubMed

    Zibrandtsen, I C; Kidmose, P; Christensen, C B; Kjaer, T W

    2017-12-01

    Ear-EEG is recording of electroencephalography from a small device in the ear. This is the first study to compare ictal and interictal abnormalities recorded with ear-EEG and simultaneous scalp-EEG in an epilepsy monitoring unit. We recorded and compared simultaneous ear-EEG and scalp-EEG from 15 patients with suspected temporal lobe epilepsy. EEGs were compared visually by independent neurophysiologists. Correlation and time-frequency analysis was used to quantify the similarity between ear and scalp electrodes. Spike-averages were used to assess similarity of interictal spikes. There were no differences in sensitivity or specificity for seizure detection. Mean correlation coefficient between ear-EEG and nearest scalp electrode was above 0.6 with a statistically significant decreasing trend with increasing distance away from the ear. Ictal morphology and frequency dynamics can be observed from visual inspection and time-frequency analysis. Spike averages derived from ear-EEG electrodes yield a recognizable spike appearance. Our results suggest that ear-EEG can reliably detect electroencephalographic patterns associated with focal temporal lobe seizures. Interictal spike morphology from sufficiently large temporal spike sources can be sampled using ear-EEG. Ear-EEG is likely to become an important tool in clinical epilepsy monitoring and diagnosis. Copyright © 2017 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.

  20. New Evaluation of the Electronically Activated Recorder (EAR): Obtrusiveness, Compliance, and Participant Self-selection Effects.

    PubMed

    Manson, Joseph H; Robbins, Megan L

    2017-01-01

    The Electronically Activated Recorder (EAR) is a method for collecting periodic brief audio snippets of participants' daily lives using a portable recording device. The EAR can potentially intrude into people's privacy, alter their natural behavior, and introduce self-selection biases greater than in other types of social science methods. Previous research (Mehl and Holleran, 2007, hereafter M&H) has shown that participant non-compliance with, and perceived obtrusiveness of, an EAR protocol are both low. However, these questions have not been addressed in jurisdictions that require the consent of all parties to recording conversations. This EAR study required participants to wear a button bearing a microphone icon and the words "This conversation may be recorded" to comply with California's all-party consent law. Results revealed self-reported obtrusiveness and non-compliance were actually lower in the present study than in the M&H study. Behaviorally assessed non-compliance did not differ between the two studies. Participants in the present study talked more about being in the study than participants in the M&H study, but such talk still comprised <2% of sampled conversations. Another potential problem with the EAR, participant self-selection bias, was addressed by comparing the EAR volunteers' HEXACO personality dimensions to a non-volunteer sample drawn from the same student population. EAR volunteers were significantly and moderately higher in Conscientiousness, and lower in Emotionality, than non-volunteers. In conclusion, the EAR method can be successfully implemented in at least one all-party consent state (California). Interested researchers are encouraged to review this procedure with their own legal counsel.

  1. Words matter: Implementing the electronically activated recorder in schizotypy.

    PubMed

    Minor, Kyle S; Davis, Beshaun J; Marggraf, Matthew P; Luther, Lauren; Robbins, Megan L

    2018-03-01

    In schizophrenia-spectrum populations, analyzing the words people use has offered promise for unlocking information about affective states and social behaviors. The electronically activated recorder (EAR) is an application-based program that is combined with widely used smartphone technology to capture a person's real-world interactions via audio recordings. It improves on the ecological validity of current methodologies by providing objective and naturalistic samples of behavior. This study is the first to implement the EAR in people endorsing elevated traits of schizophrenia-spectrum personality disorders (i.e., schizotypy), and we expected the EAR to (a) differentiate high and low schizotypy groups on affective disturbances and social engagement and (b) show that high schizotypy status moderates links between affect and social behavior using a multimethod approach. Lexical analysis of EAR recordings revealed greater negative affect and decreased social engagement in those high in schizotypy. When assessing specific traits, EAR and ecological momentary assessment (EMA) converged to show that positive schizotypy predicted negative affect. Finally, high schizotypy status moderated links between negative affect and social engagement when the EAR was combined with EMA. Adherence did not influence results, as both groups wore the EAR more than 90% of their waking hours. Findings supported using the EAR to assess real-world expressions of personality and functioning in schizotypy. Evidence also showed that the EAR can be used alongside EMA to provide a mixed-method, real-world assessment that is high in ecological validity and offers a window into the daily lives of those with elevated traits of schizophrenia-spectrum personality disorders. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  2. Wearable In-Ear Encephalography Sensor for Monitoring Sleep. Preliminary Observations from Nap Studies.

    PubMed

    Looney, David; Goverdovsky, Valentin; Rosenzweig, Ivana; Morrell, Mary J; Mandic, Danilo P

    2016-12-01

    To date, EEG is the only quantifiable measure of the neural changes that define sleep. Although it is used widely for clinical testing, scalp-electrode EEG is costly and is poorly tolerated by sleeping patients. This was a pilot study to assess the agreement between EEG recordings obtained from a new ear-EEG sensor and those obtained simultaneously from standard scalp electrodes. Participants were four healthy men, 25 to 36 years of age. During naps, EEG tracings were recorded simultaneously from the ear sensor and from standard scalp electrodes. A clinical expert, blinded to the data collection, analyzed 30-second epochs of recordings from both devices, using standardized criteria. The agreement between scalp- and ear-recordings was assessed. We scored 360 epochs (scalp-EEG and ear-EEG), of which 254 (70.6%) were scored as non-REM sleep using scalp-EEG. The ear-EEG sensor had a sensitivity of 0.88 (95% confidence interval [CI], 0.82-0.92) and a specificity of 0.78 (95% CI, 0.70-0.84) in detecting N2/N3 sleep. The kappa coefficient between the scalp- and the ear-EEG was 0.65 (95% CI, 0.58-0.73). As a sleep monitor (all non-REM sleep stages vs. wake), the in-ear sensor had a sensitivity of 0.91 (95% CI, 0.87-0.94) and a specificity of 0.66 (95% CI, 0.56-0.75). The kappa coefficient was 0.60 (95% CI, 0.50-0.69). Substantial agreement was observed between recordings derived from a new ear-EEG sensor and conventional scalp electrodes on four healthy volunteers during daytime naps.

  3. 15 CFR 732.5 - Steps regarding Shipper's Export Declaration or Automated Export System record, Destination...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... than anti-terrorism (AT). The only exception to this requirement would be the return of unwanted... be entered on the invoice and on the bill of lading, air waybill, or other export control document... THE EAR § 732.5 Steps regarding Shipper's Export Declaration or Automated Export System record...

  4. 15 CFR 732.5 - Steps regarding Shipper's Export Declaration or Automated Export System record, Destination...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... than anti-terrorism (AT). The only exception to this requirement would be the return of unwanted... be entered on the invoice and on the bill of lading, air waybill, or other export control document... THE EAR § 732.5 Steps regarding Shipper's Export Declaration or Automated Export System record...

  5. 15 CFR 732.5 - Steps regarding Shipper's Export Declaration or Automated Export System record, Destination...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... than anti-terrorism (AT). The only exception to this requirement would be the return of unwanted... be entered on the invoice and on the bill of lading, air waybill, or other export control document... THE EAR § 732.5 Steps regarding Shipper's Export Declaration or Automated Export System record...

  6. 15 CFR 732.5 - Steps regarding Shipper's Export Declaration or Automated Export System record, Destination...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... than anti-terrorism (AT). The only exception to this requirement would be the return of unwanted... be entered on the invoice and on the bill of lading, air waybill, or other export control document... THE EAR § 732.5 Steps regarding Shipper's Export Declaration or Automated Export System record...

  7. [Effect of the middle ear status on the recording of vestibular evoked myogenic potential--VEMP].

    PubMed

    Kurzyna, Agnieszka; Hassmann-Poznańska, Elzbieta; Topolska, Małgorzata Maria

    2005-01-01

    The aim of this study was to assess the effect of the middle ear status on the recording of air- and bone-conducted vestibular evoked myogenic potential. Forty eight children were included in the study, ranging in age from 4 to 10 years. All of the children underwent otoscopy, pure tone audiometry, tympanometry and air- and bone-conducted VEMP in response to click. There were 3 groups according to the condition of the middle ear: group I--52 ears (type A and C1 tympanogram, pure tone average < or = 20 dB), group II--23 ears (type C2 and B tympanogram, pure tone average < or = 20 dB), group III--21 (type B tympanogram, pure tone average > 20 dB). The threshold, presence of correct waveform morphology of the response and latency was evaluated. The condition of the middle ear has no significant effect on the recording of VEMP and mean level of the response threshold with bone stimulation, based on the performed studies. However, with air stimulation it has effect on the recording of VEMP, increase of the mean threshold response and shortening of latency p13 and n23.

  8. New Evaluation of the Electronically Activated Recorder (EAR): Obtrusiveness, Compliance, and Participant Self-selection Effects

    PubMed Central

    Manson, Joseph H.; Robbins, Megan L.

    2017-01-01

    The Electronically Activated Recorder (EAR) is a method for collecting periodic brief audio snippets of participants’ daily lives using a portable recording device. The EAR can potentially intrude into people’s privacy, alter their natural behavior, and introduce self-selection biases greater than in other types of social science methods. Previous research (Mehl and Holleran, 2007, hereafter M&H) has shown that participant non-compliance with, and perceived obtrusiveness of, an EAR protocol are both low. However, these questions have not been addressed in jurisdictions that require the consent of all parties to recording conversations. This EAR study required participants to wear a button bearing a microphone icon and the words “This conversation may be recorded” to comply with California’s all-party consent law. Results revealed self-reported obtrusiveness and non-compliance were actually lower in the present study than in the M&H study. Behaviorally assessed non-compliance did not differ between the two studies. Participants in the present study talked more about being in the study than participants in the M&H study, but such talk still comprised <2% of sampled conversations. Another potential problem with the EAR, participant self-selection bias, was addressed by comparing the EAR volunteers’ HEXACO personality dimensions to a non-volunteer sample drawn from the same student population. EAR volunteers were significantly and moderately higher in Conscientiousness, and lower in Emotionality, than non-volunteers. In conclusion, the EAR method can be successfully implemented in at least one all-party consent state (California). Interested researchers are encouraged to review this procedure with their own legal counsel. PMID:28503162

  9. Handheld tympanometer measurements in conscious dogs for the evaluation of the middle ear and auditory tube.

    PubMed

    Strain, George M; Fernandes, Asia J

    2015-06-01

    Otitis externa is frequently accompanied by otitis media, yet it can be difficult to evaluate the tympanum, middle ear and auditory tube without the use of advanced radiographic imaging. The objective was to develop techniques for tympanometry testing in conscious dogs and to present normative data for clinical use of this equipment to enable assessment of the tympanum, middle ear and auditory tube. Sixteen hounds (14 female) from a school teaching colony. Dogs were gently restrained in a standing position. After cleaning of the ear canal, a tympanometer probe tip extension was placed in the vertical canal and automated testing performed using a handheld device. Both ears were tested in all dogs. Acceptable recordings were obtained from both ears of 13 dogs, from one ear in each of two dogs and from neither ear of one dog, resulting in data from 28 of 32 (88%) ears. Otoscopic examination confirmed the absence of inflammation or any other obvious explanation for the noncompliant dogs. No significant differences were seen between ears for any measure. Normative data are reported for peak compliance, peak compliance pressure, gradient and ear canal volume. Tympanograms can be recorded in conscious dogs to assist in the evaluation of the middle ear structures. © 2015 ESVD and ACVD.

  10. Better late than never: effective air-borne hearing of toads delayed by late maturation of the tympanic middle ear structures.

    PubMed

    Womack, Molly C; Christensen-Dalsgaard, Jakob; Hoke, Kim L

    2016-10-15

    Most vertebrates have evolved a tympanic middle ear that enables effective hearing of airborne sound on land. Although inner ears develop during the tadpole stages of toads, tympanic middle ear structures are not complete until months after metamorphosis, potentially limiting the sensitivity of post-metamorphic juveniles to sounds in their environment. We tested the hearing of five species of toads to determine how delayed ear development impairs airborne auditory sensitivity. We performed auditory brainstem recordings to test the hearing of the toads and used micro-computed tomography and histology to relate the development of ear structures to hearing ability. We found a large (14-27 dB) increase in hearing sensitivity from 900 to 2500 Hz over the course of ear development. Thickening of the tympanic annulus cartilage and full ossification of the middle ear bone are associated with increased hearing ability in the final stages of ear maturation. Thus, juvenile toads are at a hearing disadvantage, at least in the high-frequency range, throughout much of their development, because late-forming ear elements are critical to middle ear function at these frequencies. We discuss the potential fitness consequences of late hearing development, although research directly addressing selective pressures on hearing sensitivity across ontogeny is lacking. Given that most vertebrate sensory systems function very early in life, toad tympanic hearing may be a sensory development anomaly. © 2016. Published by The Company of Biologists Ltd.

  11. The frequency range of TMJ sounds.

    PubMed

    Widmalm, S E; Williams, W J; Djurdjanovic, D; McKay, D C

    2003-04-01

    There are conflicting opinions about the frequency range of temporomandibular joint (TMJ) sounds. Some authors claim that the upper limit is about 650 Hz. The aim was to test the hypothesis that TMJ sounds may contain frequencies well above 650 Hz but that significant amounts of their energy are lost if the vibrations are recorded using contact sensors and/or travel far through the head tissues. Time-frequency distributions of 172 TMJ clickings (three subjects) were compared between recordings with one microphone in the ear canal and a skin contact transducer above the clicking joint and between recordings from two microphones, one in each ear canal. The energy peaks of the clickings recorded with a microphone in the ear canal on the clicking side were often well above 650 Hz and always in a significantly higher area (range 117-1922 Hz, P < 0.05 or lower) than in recordings obtained with contact sensors (range 47-375 Hz) or in microphone recordings from the opposite ear canal (range 141-703 Hz). Future studies are required to establish normative frequency range values of TMJ sounds but need methods also capable of recording the high frequency vibrations.

  12. Bilateral external ear canal osteomas - discussion on a clinical case.

    PubMed

    Gheorghe, D C; Stanciu, A E; Ulici, A; Zamfir-Chiru-Anton, A

    2016-01-01

    Osteomas of the external ear are uncommon benign tumors that need to be differentiated from the external ear canal exostoses, bony proliferations that are linked mainly to cold-water exposure. Clinical manifestations vary from no symptoms to recurrent local infections and external ear cholesteatoma. Objective: presenting a rare case that we did not find described in the published literature. A patient with multiple long-term asymptomatic osteomas of both external ear canals presented to our department. Material: Data recorded from the patient's medical record was reviewed and analyzed. Surgery was performed and histology confirmed the presumptive diagnosis. Results: There was a discrepancy between the local severity of the disease, with a complete obstruction of his ear canals, and the long-term disease-free status of the patient. Conclusion: We hypothesized about the etiology of these multiple bilateral osteomas of the EAC, in light of the clinical and surgical findings.

  13. Morphological Variations and Biometrics of Ear: An Aid to Personal Identification.

    PubMed

    Verma, Pradhuman; Sandhu, Harpreet Kaur; Verma, Kanika Gupta; Goyal, Sharry; Sudan, Madhu; Ladgotra, Amit

    2016-05-01

    The morphological characteristics and dimensions of external ear vary in different human ethnic races which can be utilized in forensics for personal identification of living or deceased. To determine uniqueness of morphological and biometric variations of both ears for individualization among North East (NE) and North West (NW) subpopulation of India. The study was conducted on randomly selected 80 students, 40 from each subgroup. Nine ear parameters were recorded twice using digital Vernier's caliper by single investigator and two indices (Ear Index and Lobule Index) were calculated for both the ears. Morphological ear shapes and lobule attachment were also noted. Pearson's coefficient correlation test was performed on cross-tabulations to evaluate significant relationship between different variables. Of the total 35% free and 65% attached ear lobes were noted in both population groups. Oval ear shape was most commonly noted followed by triangular, rectangular and round in both populations. On comparing anthropometric measurements of ears in two populations it was found that except the tragus length and lobule index all other values were noted more in NW population. No statistical difference was found in ear and lobular indices of males and females although the left ear index and lobule index were found to be higher than right in both populations except in NW females where right lobule index was recorded more than left. The results obtained can be used in anthropological and forensic sciences for the inclusion and exclusion of persons for identification on the basis of ear variations.

  14. The Auditory System of the Dipteran Parasitoid Emblemasoma auditrix (Sarcophagidae).

    PubMed

    Tron, Nanina; Stölting, Heiko; Kampschulte, Marian; Martels, Gunhild; Stumpner, Andreas; Lakes-Harlan, Reinhard

    2016-01-01

    Several taxa of insects evolved a tympanate ear at different body positions, whereby the ear is composed of common parts: a scolopidial sense organ, a tracheal air space, and a tympanal membrane. Here, we analyzed the anatomy and physiology of the ear at the ventral prothorax of the sarcophagid fly, Emblemasoma auditrix (Soper). We used micro-computed tomography to analyze the ear and its tracheal air space in relation to the body morphology. Both tympana are separated by a small cuticular bridge, face in the same frontal direction, and are backed by a single tracheal enlargement. This enlargement is connected to the anterior spiracles at the dorsofrontal thorax and is continuous with the tracheal network in the thorax and in the abdomen. Analyses of responses of auditory afferents and interneurons show that the ear is broadly tuned, with a sensitivity peak at 5 kHz. Single-cell recordings of auditory interneurons indicate a frequency- and intensity-dependent tuning, whereby some neurons react best to 9 kHz, the peak frequency of the host's calling song. The results are compared to the convergently evolved ear in Tachinidae (Diptera). © The Authors 2016. Published by Oxford University Press on behalf of Entomological Society of America.

  15. The Auditory System of the Dipteran Parasitoid Emblemasoma auditrix (Sarcophagidae)

    PubMed Central

    Tron, Nanina; Stölting, Heiko; Kampschulte, Marian; Martels, Gunhild; Stumpner, Andreas; Lakes-Harlan, Reinhard

    2016-01-01

    Several taxa of insects evolved a tympanate ear at different body positions, whereby the ear is composed of common parts: a scolopidial sense organ, a tracheal air space, and a tympanal membrane. Here, we analyzed the anatomy and physiology of the ear at the ventral prothorax of the sarcophagid fly, Emblemasoma auditrix (Soper). We used micro-computed tomography to analyze the ear and its tracheal air space in relation to the body morphology. Both tympana are separated by a small cuticular bridge, face in the same frontal direction, and are backed by a single tracheal enlargement. This enlargement is connected to the anterior spiracles at the dorsofrontal thorax and is continuous with the tracheal network in the thorax and in the abdomen. Analyses of responses of auditory afferents and interneurons show that the ear is broadly tuned, with a sensitivity peak at 5 kHz. Single-cell recordings of auditory interneurons indicate a frequency- and intensity-dependent tuning, whereby some neurons react best to 9 kHz, the peak frequency of the host’s calling song. The results are compared to the convergently evolved ear in Tachinidae (Diptera). PMID:27538415

  16. Early Human Speciation, Brain Expansion and Dispersal Influenced by African Climate Pulses

    PubMed Central

    Shultz, Susanne; Maslin, Mark

    2013-01-01

    Early human evolution is characterised by pulsed speciation and dispersal events that cannot be explained fully by global or continental paleoclimate records. We propose that the collated record of ephemeral East African Rift System (EARS) lakes could be a proxy for the regional paleoclimate conditions experienced by early hominins. Here we show that the presence of these lakes is associated with low levels of dust deposition in both West African and Mediterranean records, but is not associated with long-term global cooling and aridification of East Africa. Hominin expansion and diversification seem to be associated with climate pulses characterized by the precession-forced appearance and disappearance of deep EARS lakes. The most profound period for hominin evolution occurs at about 1.9 Ma; with the highest recorded diversity of hominin species, the appearance of Homo (sensu stricto) and major dispersal events out of East Africa into Eurasia. During this period, ephemeral deep-freshwater lakes appeared along the whole length of the EARS, fundamentally changing the local environment. The relationship between the local environment and hominin brain expansion is less clear. The major step-wise expansion in brain size around 1.9 Ma when Homo appeared was coeval with the occurrence of ephemeral deep lakes. Subsequent incremental increases in brain size are associated with dry periods with few if any lakes. Plio-Pleistocene East African climate pulses as evinced by the paleo-lake records seem, therefore, fundamental to hominin speciation, encephalisation and migration. PMID:24146922

  17. Early human speciation, brain expansion and dispersal influenced by African climate pulses.

    PubMed

    Shultz, Susanne; Maslin, Mark

    2013-01-01

    Early human evolution is characterised by pulsed speciation and dispersal events that cannot be explained fully by global or continental paleoclimate records. We propose that the collated record of ephemeral East African Rift System (EARS) lakes could be a proxy for the regional paleoclimate conditions experienced by early hominins. Here we show that the presence of these lakes is associated with low levels of dust deposition in both West African and Mediterranean records, but is not associated with long-term global cooling and aridification of East Africa. Hominin expansion and diversification seem to be associated with climate pulses characterized by the precession-forced appearance and disappearance of deep EARS lakes. The most profound period for hominin evolution occurs at about 1.9 Ma; with the highest recorded diversity of hominin species, the appearance of Homo (sensu stricto) and major dispersal events out of East Africa into Eurasia. During this period, ephemeral deep-freshwater lakes appeared along the whole length of the EARS, fundamentally changing the local environment. The relationship between the local environment and hominin brain expansion is less clear. The major step-wise expansion in brain size around 1.9 Ma when Homo appeared was coeval with the occurrence of ephemeral deep lakes. Subsequent incremental increases in brain size are associated with dry periods with few if any lakes. Plio-Pleistocene East African climate pulses as evinced by the paleo-lake records seem, therefore, fundamental to hominin speciation, encephalisation and migration.

  18. Prevalence of clinical abnormalities in cats found to have nonneoplastic middle ear disease at necropsy: 59 cases (1991-2007).

    PubMed

    Schlicksup, Michael D; Van Winkle, Thomas J; Holt, David E

    2009-10-01

    To determine the prevalence of nonneoplastic middle ear disease among cats undergoing necropsy and the prevalence of clinical abnormalities in cats in which nonneoplastic middle ear disease was identified. Retrospective case series. 59 cats that underwent necropsy between January 1991 and August 2007. Medical records were searched to identify cats in which nonneoplastic middle ear disease was identified at necropsy. For cats included in the study, data that were recorded included signalment, initial complaint, whether the cat had any clinical signs of middle or external ear disease, whether the cat had upper respiratory tract disease, necropsy diagnosis, gross appearance of the bullae, and reason for euthanasia. Signs of middle ear disease that were considered included unilateral peripheral vestibular disease without motor deficits, Horner syndrome, and facial nerve paralysis. Of the 3,442 cats that underwent necropsy during the study period, 59 (1.7%) had nonneoplastic middle ear disease. Six of the 59 (10%) cats, including 1 cat that was affected bilaterally, had clinical signs of middle ear disease. Of these, 5 had signs of unilateral peripheral vestibular disease, and 1 had Horner syndrome. Results suggested that most cats with nonneoplastic middle ear disease did not have associated clinical signs. Findings may be of clinical relevance for cats in which middle ear disease is identified as an incidental finding during computed tomography or magnetic resonance imaging for unrelated diseases.

  19. Effect Of Electromagnetic Waves Emitted From Mobile Phone On Brain Stem Auditory Evoked Potential In Adult Males.

    PubMed

    Singh, K

    2015-01-01

    Mobile phone (MP) is commonly used communication tool. Electromagnetic waves (EMWs) emitted from MP may have potential health hazards. So, it was planned to study the effect of electromagnetic waves (EMWs) emitted from the mobile phone on brainstem auditory evoked potential (BAEP) in male subjects in the age group of 20-40 years. BAEPs were recorded using standard method of 10-20 system of electrode placement and sound click stimuli of specified intensity, duration and frequency.Right ear was exposed to EMW emitted from MP for about 10 min. On comparison of before and after exposure to MP in right ear (found to be dominating ear), there was significant increase in latency of II, III (p < 0.05) and V (p < 0.001) wave, amplitude of I-Ia wave (p < 0.05) and decrease in IPL of III-V wave (P < 0.05) after exposure to MP. But no significant change was found in waves of BAEP in left ear before vs after MP. On comparison of right (having exposure routinely as found to be dominating ear) and left ears (not exposed to MP), before exposure to MP, IPL of IIl-V wave and amplitude of V-Va is more (< 0.001) in right ear compared to more latency of III and IV wave (< 0.001) in left ear. After exposure to MP, the amplitude of V-Va was (p < 0.05) more in right ear compared to left ear. In conclusion, EMWs emitted from MP affects the auditory potential.

  20. Is the Okavango Delta the terminus of the East African Rift System? Towards a new geodynamic model: Geodetic study and geophysical review

    NASA Astrophysics Data System (ADS)

    Pastier, Anne-Morwenn; Dauteuil, Olivier; Murray-Hudson, Michael; Moreau, Frédérique; Walpersdorf, Andrea; Makati, Kaelo

    2017-08-01

    The Okavango Graben (OG) has been considered as the terminus of the southwestern branch of the East African Rift System (EARS) since the 1970s based on fault morphology and early seismic and geophysical data. Thus it has been assumed to be an incipient rifting zone, analogous to the early stage of mature rifts in the EARS. Recent geodetic data and geophysical studies in the area bring new insights into the local crust and lithosphere, mantle activity and fault activity. In this study, we computed the velocities for three permanent GPS stations surrounding the graben and undertook a review of the new geophysical data available for the area. The northern and southern blocks of the graben show an exclusively low strike-slip displacement rate of about 1mm/year, revealing the transtensional nature of this basin. The seismic record of central and southern Africa was found to be instrumentally biased for the events recorded before 2004 and the OG may not represent the most seismically active area in Botswana anymore. Moreover, no significant lithosphere and crustal thinning is found in the tectonic structure nor any strong negative Bouguer anomaly and surface heat flux. Thus the OG does not match the classical model for a rifting zone. We propose a new geodynamic model for the deformation observed west of the EARS based on accommodation of far-field deformation due to the differential extension rates of the EARS and the displacement of the Kalahari craton relative to the Nubian plate.

  1. Adaptive Wiener filtering for improved acquisition of distortion product otoacoustic emissions.

    PubMed

    Ozdamar, O; Delgado, R E; Rahman, S; Lopez, C

    1998-01-01

    An innovative acoustic noise canceling method using adaptive Wiener filtering (AWF) was developed for improved acquisition of distortion product otoacoustic emissions (DPOAEs). The system used one microphone placed in the test ear for the primary signal. Noise reference signals were obtained from three different sources: (a) pre-stimulus response from the test ear microphone, (b) post-stimulus response from a microphone placed near the head of the subject and (c) post-stimulus response obtained from a microphone placed in the subject's nontest ear. In order to improve spectral estimation, block averaging of a different number of single sweep responses was used. DPOAE data were obtained from 11 ears of healthy newborns in a well-baby nursery of a hospital under typical noise conditions. Simultaneously obtained recordings from all three microphones were digitized, stored and processed off-line to evaluate the effects of AWF with respect to DPOAE detection and signal-to-noise ratio (SNR) improvement. Results show that compared to standard DPOAE processing, AWF improved signal detection and improved SNR.

  2. Classification of Newborn Ear Malformations and their Treatment with the EarWell Infant Ear Correction System.

    PubMed

    Daniali, Lily N; Rezzadeh, Kameron; Shell, Cheryl; Trovato, Matthew; Ha, Richard; Byrd, H Steve

    2017-03-01

    A single practice's treatment protocol and outcomes following molding therapy on newborn ear deformations and malformations with the EarWell Infant Ear Correction System were reviewed. A classification system for grading the severity of constricted ear malformations was created on the basis of anatomical findings. A retrospective chart/photograph review of a consecutive series of infants treated with the EarWell System from 2011 to 2014 was undertaken. The infants were placed in either deformation or malformation groups. Three classes of malformation were identified. Data regarding treatment induction, duration of treatment, and quality of outcome were collected for all study patients. One hundred seventy-five infant ear malformations and 303 infant ear deformities were treated with the EarWell System. The average age at initiation of treatment was 12 days; the mean duration of treatment was 37 days. An average of six office visits was required. Treated malformations included constricted ears [172 ears (98 percent)] and cryptotia [three ears (2 percent)]. Cup ear (34 ears) was considered a constricted malformation, in contrast to the prominent ear deformity. Constricted ears were assigned to one of three classes, with each subsequent class indicating increasing severity: class I, 77 ears (45 percent); class II, 81 ears (47 percent); and class III, 14 ears (8 percent). Molding therapy with the EarWell System reduced the severity by an average of 1.2 points (p < 0.01). Complications included minor superficial excoriations and abrasions. The EarWell System was shown to be effective in eliminating or reducing the need for surgery in all but the most severe malformations. Therapeutic, IV.

  3. Extracellular and intracellular melanin in inflammatory middle ear disease.

    PubMed

    Fritz, Mark A; Roehm, Pamela C; Bannan, Michael A; Lalwani, Anil K

    2014-06-01

    Melanin is a pigmented polymer with a known role in dermal solar protection. In vertebrates, melanogenesis has been reported in leukocyte populations, suggesting a potential role in innate immunity. In this study, we report the novel finding of melanin associated with chronic inflammation and speculate on its potential role in the middle ear and mastoid. Retrospective review of case series. Medical records of six patients who demonstrated melanin in the ear were reviewed. Six patients from 1 to 63 years of age were identified with extracellular melanin and melanin-laden histiocytes within the middle ear and/or mastoid air cells at time of surgery. Concurrent intraoperative findings included cholesteatoma (n = 3), chronic suppurative otitis media (n = 2), and coalescent mastoiditis (n = 1). Histologically, extracellular melanin and melanin-laden histiocytes were identified by Fontana-Masson stain; absence of melanocytes was confirmed by the absence of Melan-A staining. One patient had a positive stain for CD163 (a marker for macrophages). This case series is the first demonstration of melanin within middle ear mucosa without melanocytes in immediate proximity or metastatic melanocytic lesions. Melanin's presence in the setting of inflammation suggests that there may be a heretofore unreported link between the pigmentary and immune systems in the middle ear. 4.

  4. The division of attention and the human auditory evoked potential

    NASA Technical Reports Server (NTRS)

    Hink, R. F.; Van Voorhis, S. T.; Hillyard, S. A.; Smith, T. S.

    1977-01-01

    The sensitivity of the scalp-recorded, auditory evoked potential to selective attention was examined while subjects responded to stimuli presented to one ear (focused attention) and to both ears (divided attention). The amplitude of the N1 component was found to be largest to stimuli in the ear upon which attention was to be focused, smallest to stimuli in the ear to be ignored, and intermediate to stimuli in both ears when attention was divided. The results are interpreted as supporting a capacity model of attention.

  5. Phonemic Awareness and Middle-Ear Disease among Bedouin Arabs in Israel.

    ERIC Educational Resources Information Center

    Abu-Rabia, Salim

    2002-01-01

    Investigates the effect of middle-ear infections on phonemic awareness on first-grade Bedouin Arab elementary school children in northern Israel. Divides 49 children who were screened according to their infant medical records into two groups: one with repeated middle-ear infection and one without. Indicates a nonsignificant effect of middle-ear…

  6. The measurement of Eustachian tube function in a hyperbaric chamber using an ear canal microphone.

    PubMed

    Fischer, Hans-Georg; Koch, Andreas; Kähler, Wataru; Pohl, Michael; Pau, Hans-Wilhelm; Zehlicke, Thorsten

    2016-03-01

    The purpose of this study was to further the understanding of the opening of the Eustachian tube in relation to changes in barometric pressure. An ear canal microphone was used to measure the specific sounds related to tube opening and possible eardrum movements. Five subjects with normal tube function were examined in a hyperbaric chamber (up to 304 kPa). All active and passive equalization events were recorded and correlated with the subjectively perceived pressure regulation in the measured ear. The signals recorded were clear and reproducible. The acoustic analysis distinguished between the different kinds of equalization. Subjective impressions were confirmed by the recorded frequency of acoustic phenomena (clicks). During compression, the sequence of active equalization manoeuvres was in a more regular and steady pattern than during decompression, when the click sounds varied. The study established a simple technical method for analyzing the function of the Eustachian tube and provided new information about barometric pressure regulation of the middle ear.

  7. Are two ears not better than one?

    PubMed

    McArdle, Rachel A; Killion, Mead; Mennite, Monica A; Chisolm, Theresa H

    2012-03-01

    The decision to fit one or two hearing aids in individuals with binaural hearing loss has been debated for years. Although some 78% of U.S. hearing aid fittings are binaural (Kochkin , 2010), Walden and Walden (2005) presented data showing that 82% (23 of 28 patients) of their sample obtained significantly better speech recognition in noise scores when wearing one hearing aid as opposed to two. To conduct two new experiments to fuel the monaural/binaural debate. The first experiment was a replication of Walden and Walden (2005), whereas the second experiment examined the use of binaural cues to improve speech recognition in noise. A repeated measures experimental design. Twenty veterans (aged 59-85 yr), with mild to moderately severe binaurally symmetrical hearing loss who wore binaural hearing aids were recruited from the Audiology Department at the Bay Pines VA Healthcare System. Experiment 1 followed the procedures of the Walden and Walden study, where signal-to-noise ratio (SNR) loss was measured using the Quick Speech-in-Noise (QuickSIN) test on participants who were aided with their current hearing aids. Signal and noise were presented in the sound booth at 0° azimuth under five test conditions: (1) right ear aided, (2) left ear aided, (3) both ears aided, (4) right ear aided, left ear plugged, and (5) unaided. The opposite ear in (1) and (2) was left open. In Experiment 2, binaural Knowles Electronics Manikin for Acoustic Research (KEMAR) manikin recordings made in Lou Malnati's pizza restaurant during a busy period provided a typical real-world noise, while prerecorded target sentences were presented through a small loudspeaker located in front of the KEMAR manikin. Subjects listened to the resulting binaural recordings through insert earphones under the following four conditions: (1) binaural, (2) diotic, (3) monaural left, and (4) monaural right. Results of repeated measures ANOVAs demonstrated that the best speech recognition in noise performance was obtained by most participants with both ears aided in Experiment 1 and in the binaural condition in Experiment 2. In both experiments, only 20% of our subjects did better in noise with a single ear, roughly similar to the earlier Jerger et al (1993) finding that 8-10% of elderly hearing aid users preferred one hearing aid. American Academy of Audiology.

  8. Long-term evaluation of the effect of middle ear effusion on the vestibular system in children.

    PubMed

    Pazdro-Zastawny, Katarzyna; Pośpiech, Lucyna; Zatoński, Tomasz

    2018-06-01

    Otitis media with effusion (OME) is one of the most common clinical conditions in childhood. Fluid accumulation in the middle ear may impact inner ear. The purpose of this random sample cohort study was to investigate whether the past history of middle ear effusion has a long-term negative impact on the vestibular system in children. The study was carried out on 22 children aged 7-15 years who had undergone drainage of the middle ear 5 years before evaluation. The control group consisted of 29 healthy children aged 4-17 years. Vestibular function was examined using sway posturography and electronystagmography (ENG). The stabilogram parameters of the study group and the control group were compared. The field of developed area (FDA) and the average body sway velocity (ASV) were analyzed. Elevated stabilogram parameters of FDA and ASV, both with eyes open and eyes closed, were found in the study group. Statistically significant values (p < 0.05) were present for ASV with eyes open and with eyes closed. The ENG recordings were analyzed in both groups. In the study group, spontaneous nystagmus was observed in 40.9% of the children and positional nystagmus occurred in 63.6% of the children. According to tests, eye tracking test was impaired in 27.3% of cases. Rotatory chair testing revealed asymmetry in 18.2% of the children. The presence of effusion in the middle ear in the past has a negative impact on the vestibular part of the inner ear. Clinicians should be aware of the possible negative impact of middle ear effusion on the vestibular function in children with a history of otitis media with effusion. With seeimingly asymptomatic children clinicians should inquire parents about symptoms of dysequlibrium and imbalance. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. Identifying individual sperm whales acoustically using self-organizing maps

    NASA Astrophysics Data System (ADS)

    Ioup, Juliette W.; Ioup, George E.

    2005-09-01

    The Littoral Acoustic Demonstration Center (LADC) is a consortium at Stennis Space Center comprising the University of New Orleans, the University of Southern Mississippi, the Naval Research Laboratory, and the University of Louisiana at Lafayette. LADC deployed three Environmental Acoustic Recording System (EARS) buoys in the northern Gulf of Mexico during the summer of 2001 to study ambient noise and marine mammals. Each LADC EARS was an autonomous, self-recording buoy capable of 36 days of continuous recording of a single channel at an 11.7-kHz sampling rate (bandwidth to 5859 Hz). The hydrophone selected for this analysis was approximately 50 m from the bottom in a water depth of 800 m on the continental slope off the Mississippi River delta. This paper contains recent analysis results for sperm whale codas recorded during a 3-min period. Results are presented for the identification of individual sperm whales from their codas, using the acoustic properties of the clicks within each coda. The recorded time series, the Fourier transform magnitude, and the wavelet transform coefficients are each used separately with a self-organizing map procedure for 43 codas. All show the codas as coming from four or five individual whales. [Research supported by ONR.

  10. Hyperspectral and chlorophyll fluorescence imaging to analyse the impact of Fusarium culmorum on the photosynthetic integrity of infected wheat ears.

    PubMed

    Bauriegel, Elke; Giebel, Antje; Herppich, Werner B

    2011-01-01

    Head blight on wheat, caused by Fusarium spp., is a serious problem for both farmers and food production due to the concomitant production of highly toxic mycotoxins in infected cereals. For selective mycotoxin analyses, information about the on-field status of infestation would be helpful. Early symptom detection directly on ears, together with the corresponding geographic position, would be important for selective harvesting. Hence, the capabilities of various digital imaging methods to detect head blight disease on winter wheat were tested. Time series of images of healthy and artificially Fusarium-infected ears were recorded with a laboratory hyperspectral imaging system (wavelength range: 400 nm to 1,000 nm). Disease-specific spectral signatures were evaluated with an imaging software. Applying the 'Spectral Angle Mapper' method, healthy and infected ear tissue could be clearly classified. Simultaneously, chlorophyll fluorescence imaging of healthy and infected ears, and visual rating of the severity of disease was performed. Between six and eleven days after artificial inoculation, photosynthetic efficiency of infected compared to healthy ears decreased. The severity of disease highly correlated with photosynthetic efficiency. Above an infection limit of 5% severity of disease, chlorophyll fluorescence imaging reliably recognised infected ears. With this technique, differentiation of the severity of disease was successful in steps of 10%. Depending on the quality of chosen regions of interests, hyperspectral imaging readily detects head blight 7 d after inoculation up to a severity of disease of 50%. After beginning of ripening, healthy and diseased ears were hardly distinguishable with the evaluated methods.

  11. Revisiting gender, race, and ear differences in peripheral auditory function

    NASA Astrophysics Data System (ADS)

    Boothalingam, Sriram; Klyn, Niall A. M.; Stiepan, Samantha M.; Wilson, Uzma S.; Lee, Jungwha; Siegel, Jonathan H.; Dhar, Sumitrajit

    2018-05-01

    Various measures of auditory function are reported to be superior in females as compared to males, in African American compared to Caucasian individuals, and in right compared to left ears. We re-examined the influence of these subject variables on hearing thresholds and otoacoustic emissions (OAEs) in a sample of 887 human participants between 10 and 68 years of age. Even though the variables of interest here have been examined before, previous attempts have largely been limited to frequencies up to 8 kHz. We used state-of-the-art signal delivery and recording techniques that compensated for individual differences in ear canal acoustics, allowing us to measure hearing thresholds and OAEs up to 20 kHz. The use of these modern calibration and recording techniques provided the motivation for re-examining these commonly studied variables. While controlling for age, noise exposure history, and general health history, we attempted to isolate the effects of gender, race, and ear (left versus right) on hearing thresholds and OAEs. Our results challenge the notion of a right ear advantage and question the existence of a significant gender and race differences in both hearing thresholds and OAE levels. These results suggest that ear canal anatomy and acoustics should be important considerations when evaluating the influence of gender, race, and ear on peripheral auditory function.

  12. Causes of Deafness: Retrospection and Omens.

    ERIC Educational Resources Information Center

    Champie, Joan

    1996-01-01

    This study reviewed records of several American schools for the deaf in the 19th century concerning the stated causes of deafness given by parents. The high rate of adventitious deafness is noted. Stated causes are categorized into: fevers, inflammations, medicines/poisons, trauma, heat/cold, ear problems, nervous system problems, head/neck…

  13. Long-eared owls nesting in Badlands National Park

    Treesearch

    Deborah D. Paulson; Carolyn Hull Sieg

    1985-01-01

    Long-eared Owls nest at high densities locally over the Great Plains where suitable habitat is limited (Bent 1938), yet , according to Whitney et al. (1978), this species is rare to uncommon in South Dakota. Especially west of the Missouri River, few nesting records have been reported. This paper reports the occurrence of Long-eared Owls in the Badlands National Park...

  14. Oral pseudoephedrine decreases the rate of transmucosal nitrous oxide exchange for the middle ear.

    PubMed

    Teixeira, Miriam S; Alper, Cuneyt M; Martin, Brian S; Doyle, Brendan M Cullen; Doyle, William J

    2015-09-01

    Determine if oral treatment with a vasoconstrictor decreases the blood to middle ear exchange rate of the perfusion-limited gas, nitrous oxide (N2O). Randomized, double-blind, crossover study. Ten adult subjects with and 10 without past middle ear disease completed paired experimental sessions, identical except for oral treatment with either pseudoephedrine hydrochloride or lactose placebo. At each session, subjects were fitted with a nonrebreathing mask and breathed room air for 20 minutes (acclimation period), 50% N2O:50% O2 for 20 minutes (experimental period), and 100% O2 for 10 minutes (recovery period). Throughout, heart rate, blood pressure, and O2 saturation were monitored, and bilateral middle ear pressures were recorded by tympanometry every minute. The primary outcome was the slope of the middle ear pressure-time function for the experimental period, which estimates the volume N2O exchange rate. Using repeated measures analysis of variance, the effects of group (disease history), treatment (active vs. placebo), and period (1 vs. 2) on the recorded vital signs, and of group, treatment, and ear (left/right) on the middle ear pressure-time slope were evaluated for statistical significance. Statistically significant effects of period on O2 saturation (period 2 > period 1) and of treatment on heart rate (active > placebo) were documented. Only treatment was statistically significant for the middle ear pressure-time slope, with a shallower slope characterizing the active treatment session. The volume exchange rate across the middle ear mucosa of perfusion-limited gases can be modulated pharmacologically. Theoretically, similar drugs can be used to reduce the requisite eustachian tube opening efficiency for adequate middle ear pressure regulation. 1b. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.

  15. Oral Pseudoephedrine Decreases the Rate of Trans-mucosal Nitrous Oxide Exchange for the Middle Ear

    PubMed Central

    Teixeira, Miriam S.; Alper, Cuneyt M.; Martin, Brian S; Cullen Doyle, Brendan M.; Doyle, William J.

    2015-01-01

    Objective Determine if oral pretreatment with a vasoconstrictor decreases the blood to middle-ear exchange-rate of the perfusion-limited gas, Nitrous Oxide (N2O). Study Design Randomized, double-blind, crossover study. Methods Ten adult subjects with and 10 without past middle-ear disease completed paired experimental sessions, identical but for oral pretreatment with either pseudoephedrine HCL or lactose placebo. At each session, subjects were fitted with a non-rebreathing mask and breathed room air for 20 minutes (acclimation period), 50% N2O:50% O2 for 20 minutes (experimental period) and 100% O2 for 10 minutes (recovery period). Throughout, heart-rate, blood-pressure and O2 saturation were monitored and bilateral middle-ear pressures were recorded by tympanometry every minute. The primary outcome was the slope of the middle-ear pressure-time function for the experimental period which estimates the volume N2O exchange-rate. Using repeated measures ANOVA, the effects of Group (disease history), Treatment (active vs. placebo) and Period (1 vs. 2) on the recorded vital signs, and of Group, Treatment and Ear (left/right) on the middle-ear pressure-time slope were evaluated for statistical significance. Results Statistically significant effects of Period on O2 saturation (Period 2>Period 1) and of Treatment on heart-rate (Active>Placebo) were documented. Only Treatment was statistically significant for the middle-ear pressure-time slope with a shallower slope characterizing the active treatment session. Conclusion The volume exchange-rate across the middle-ear mucosa of perfusion-limited gases can be modulated pharmacologically. Theoretically, similar drugs can be used to reduce the requisite Eustachian tube opening efficiency for adequate middle-ear pressure regulation. PMID:26152838

  16. Vestibular evoked myogenic potentials in patients with BPPV.

    PubMed

    Korres, Stavros; Gkoritsa, Eleni; Giannakakou-Razelou, Dimitra; Yiotakis, Ioannis; Riga, Maria; Nikolpoulos, Thomas P

    2011-01-01

    The probable cause of Benign Paroxysmal Positional Vertigo (BPPV) is a degeneration of the oto lithic organs (utricle and saccule). The aim of the study is to find possible alterations in Vestibular Evoked Myogenic Potentials (VEMP) recordings in BPPV patients, because the saccule is part of the VEMP pathway. 27 BPPV patients (24 unilateral and 3 bilateral) aged 20 to 70 years and 30 healthy age matched controls. BPPV was diagnosed by the upbeating geotropic nystagmus found in the supine position with the head overextended towards one side. The subjects were investigated with pure tone audiometry, bi-thermal caloric test with electronystagmographic (ENG) recording, and VEMP recording. P1 latency and N1 latency did not present any statistical difference between control ears and affected ears of the BPPV population. The percentage of abnormal VEMP in the BPPV population was statistically higher than in the control ears (p < 0.005). No significant relationship could be shown between the occurrence of Canal Paresis and abnormal VEMP. No relationship was found between the side (right or left ear) where BPPV appeared clinically and the side where abnormal VEMP was registered. BPPV is a clinical entity associated with increased occurrence of abnormal VEMP recordings, possibly due to degeneration of the saccular macula, which is part of the neural VEMP pathway.

  17. Sheep as a large animal ear model: Middle-ear ossicular velocities and intracochlear sound pressure.

    PubMed

    Péus, Dominik; Dobrev, Ivo; Prochazka, Lukas; Thoele, Konrad; Dalbert, Adrian; Boss, Andreas; Newcomb, Nicolas; Probst, Rudolf; Röösli, Christof; Sim, Jae Hoon; Huber, Alexander; Pfiffner, Flurin

    2017-08-01

    Animals are frequently used for the development and testing of new hearing devices. Dimensions of the middle ear and cochlea differ significantly between humans and commonly used animals, such as rodents or cats. The sheep cochlea is anatomically more like the human cochlea in size and number of turns. This study investigated the middle-ear ossicular velocities and intracochlear sound pressure (ICSP) in sheep temporal bones, with the aim of characterizing the sheep as an experimental model for implantable hearing devices. Measurements were made on fresh sheep temporal bones. Velocity responses of the middle ear ossicles at the umbo, long process of the incus and stapes footplate were measured in the frequency range of 0.25-8 kHz using a laser Doppler vibrometer system. Results were normalized by the corresponding sound pressure level in the external ear canal (P EC ). Sequentially, ICSPs at the scala vestibuli and tympani were then recorded with custom MEMS-based hydrophones, while presenting identical acoustic stimuli. The sheep middle ear transmitted most effectively around 4.8 kHz, with a maximum stapes velocity of 0.2 mm/s/Pa. At the same frequency, the ICSP measurements in the scala vestibuli and tympani showed the maximum gain relative to the P EC (24 dB and 5 dB, respectively). The greatest pressure difference across the cochlear partition occurred between 4 and 6 kHz. A comparison between the results of this study and human reference data showed middle-ear resonance and best cochlear sensitivity at higher frequencies in sheep. In summary, sheep can be an appropriate large animal model for research and development of implantable hearing devices. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Hydrostatic fluid pressure in the vestibular organ of the guinea pig.

    PubMed

    Park, Jonas J-H; Boeven, Jahn J; Vogel, Stefan; Leonhardt, Steffen; Wit, Hero P; Westhofen, Martin

    2012-07-01

    Since inner ear hair cells are mechano-electric transducers the control of hydrostatic pressure in the inner ear is crucial. Most studies analyzing dynamics and regulation of inner ear hydrostatic pressure performed pressure measurements in the cochlea. The present study is the first one reporting about absolute hydrostatic pressure values in the labyrinth. Hydrostatic pressure of the endolymphatic system was recorded in all three semicircular canals. Mean pressure values were 4.06 cmH(2)O ± 0.61 in the posterior, 3.36 cmH(2)O ± 0.94 in the anterior and 3.85 cmH(2)O ± 1.38 in the lateral semicircular canal. Overall hydrostatic pressure in the vestibular organ was 3.76 cmH(2)O ± 0.36. Endolymphatic hydrostatic pressure in all three semicircular canals is the same (p = 0.310). With regard to known endolymphatic pressure values in the cochlea from past studies vestibular pressure values are comparable to cochlear values. Until now it is not known whether the reuniens duct and the Bast's valve which are the narrowest passages in the endolymphatic system are open or closed. Present data show that most likely the endolymphatic system is a functionally open entity.

  19. Naturalistic Observation of Health-Relevant Social Processes: The Electronically Activated Recorder (EAR) Methodology in Psychosomatics

    PubMed Central

    Mehl, Matthias R.; Robbins, Megan L.; Deters, Fenne große

    2012-01-01

    This article introduces a novel, observational ambulatory monitoring method called the Electronically Activated Recorder or EAR. The EAR is a digital audio recorder that runs on a handheld computer and periodically and unobtrusively records snippets of ambient sounds from participants’ momentary environments. In tracking moment-to-moment ambient sounds, it yields acoustic logs of people’s days as they naturally unfold. In sampling only a fraction of the time, it protects participants’ privacy and makes large observational studies feasible. As a naturalistic observation method, it provides an observer’s account of daily life and is optimized for the objective assessment of audible aspects of social environments, behaviors, and interactions (e.g., habitual preferences for social settings, idiosyncratic interaction styles, and subtle emotional expressions). The article discusses the EAR method conceptually and methodologically, reviews prior research with it, and identifies three concrete ways in which it can enrich psychosomatic research. Specifically, it can (a) calibrate psychosocial effects on health against frequencies of real-world behavior, (b) provide ecological, observational measures of health-related social processes that are independent of self-report, and (c) help with the assessment of subtle and habitual social behaviors that evade self-report but have important health implications. An important avenue for future research lies in merging traditional, self-report based ambulatory monitoring methods with observational approaches such as the EAR to allow for the simultaneous yet methodologically independent assessment of inner, experiential (e.g., loneliness) and outer, observable aspects (e.g., social isolation) of real-world social processes to reveal their unique effects on health. PMID:22582338

  20. Geochemical evidence for pre- and syn-rifting lithospheric foundering in the East African Rift System

    NASA Astrophysics Data System (ADS)

    Nelson, W. R.; Furman, T.; Elkins-Tanton, L. T.

    2015-12-01

    The East African Rift System (EARS) is the archetypal active continental rift. The rift branches cut through the elevated Ethiopian and Kenyan domes and are accompanied by a >40 Myr volcanic record. This record is often used to understand changing mantle dynamics, but this approach is complicated by the diversity of spatio-temporally constrained, geochemically unique volcanic provinces. Various sources have been invoked to explain the geochemical variability across the EARS (e.g. mantle plume(s), both enriched and depleted mantle, metasomatized or pyroxenitic lithosphere, continental crust). Mantle contributions are often assessed assuming adiabatic melting of mostly peridotitic material due to extension or an upwelling thermal plume. However, metasomatized lithospheric mantle does not behave like fertile or depleted peridotite mantle, so this model must be modified. Metasomatic lithologies (e.g. pyroxenite) are unstable compared to neighboring peridotite and can founder into the underlying asthenosphere via ductile dripping. As such a drip descends, the easily fusible metasomatized lithospheric mantle heats conductively and melts at increasing T and P; the subsequent volcanic products in turn record this drip magmatism. We re-evaluated existing data of major mafic volcanic episodes throughout the EARS to investigate potential evidence for lithospheric drip foundering that may be an essential part of the rifting process. The data demonstrate clearly that lithospheric drip melting played an important role in pre-flood basalt volcanism in Turkana (>35 Ma), high-Ti "mantle plume-derived" flood basalts and picrites (HT2) from NW Ethiopia (~30 Ma), Miocene shield volcanism on the E Ethiopian Plateau and in Turkana (22-26 Ma), and Quaternary volcanism in Virunga (Western Rift) and Chyulu Hills (Eastern Rift). In contrast, there is no evidence for drip melting in "lithosphere-derived" flood basalts (LT) from NW Ethiopia, Miocene volcanism in S Ethiopia, or Quaternary within-rift lavas in Ethiopia, Turkana or Kivu. The evidence for widespread lithospheric removal across eastern Africa coincides with the timing of dome uplift (e.g. Gani et al., 2007; Wichura et al., 2015) and further demonstrates the controls of lithospheric mantle on volcano-tectonic processes throughout the evolving EARS.

  1. Ear molding in newborn infants with auricular deformities.

    PubMed

    Byrd, H Steve; Langevin, Claude-Jean; Ghidoni, Lorraine A

    2010-10-01

    A review of a single physician's experience in managing over 831 infant ear deformities (488 patients) is presented. The authors' methods of molding have advanced from the use of various tapes, glues, and stents, to a comprehensive yet simple system that shapes the antihelix, the triangular fossa, the helical rim, and the overly prominent conchal-mastoid angle (EarWell Infant Ear Correction System). The types of deformities managed, and their relative occurrence, are as follows: (1) prominent/cup ear, 373 ears (45 percent); (2) lidding/lop ear, 224 ears (27 percent); (3) mixed ear deformities, 83 ears (10 percent) (all had associated conchal crus); (4) Stahl's ear, 66 ears (8 percent); (5) helical rim abnormalities, 58 ears (7 percent); (6) conchal crus, 25 ears (3 percent); and (7) cryptotia, two ears (0.2 percent). Bilateral deformities were present in 340 patients (70 percent), with unilateral deformities in 148 patients (30 percent). Fifty-eight infant ears (34 patients) were treated using the final version of the EarWell Infant Ear Correction System with a success rate exceeding 90 percent (good to excellent results). The system was found to be most successful when begun in the first week of the infant's life. When molding was initiated after 3 weeks from birth, only approximately half of the infants had a good response. Congenital ear deformities are common and only approximately 30 percent self-correct. These deformities can be corrected by initiating appropriate molding in the first week of life. Neonatal molding reduces the need for surgical correction with results that often exceed what can be achieved with the surgical alternative.

  2. Geochemical Overview of the East African Rift System

    NASA Astrophysics Data System (ADS)

    Furman, T.

    2003-12-01

    Mafic volcanics of the East African Rift System (EARS) record a protracted history of continental extension that is linked to mantle plume activity. The modern EARS traverses two post-Miocene topographic domes separated by a region of polyphase extension in northern Kenya and southern Ethiopia. Basaltic magmatism commenced ˜45 Ma in this highly extended region, while the onset of plume-related activity took place ˜30 Ma with eruption of flood basalts in central Ethiopia. A spatial and temporal synthesis of EARS volcanic geochemistry shows progressive lithospheric removal (by erosion and melting) as the degree of rifting increases, with basalts in the most highly extended areas recording melting of depleted asthenosphere. Plume contributions are indicated locally in the northern half of the EARS, but are absent from the southern half. The geochemical signatures are compatible with a physical model in which the entire EARS is fed by a discontinuous plume emanating from the core-mantle boundary as the South African Superswell. Quaternary basaltic lavas erupted in the Afar triangle, Red Sea and Gulf of Aden define the geochemical signature attributed to the Afar plume (87Sr/86Sr 0.7034-0.7037, 143Nd/144Nd 0.5129-0.5130; La/Nb 0.6-0.9; Nb/U 40-50). These suites commonly record mixing with ambient upper mantle having less radiogenic isotopes but generally overlapping incompatible trace element abundances. Within the Ethiopian dome both lithospheric and sub-lithoshperic contributions can be documented clearly; lithospheric contributions are manifest in more radiogenic isotope values (87Sr/86Sr up to 0.7050) and distinctive trace element abundances (e.g., La/Nb <2.0, Nb/U > 10). The degree of lithospheric contribution is lowest within the active Main Ethiopian Rift and increases towards the southern margin of the dome. The estimated depth of melting (65-75 km) is consistent with geophysical observations of lithospheric thickness. In regions of prolonged volcanism the lithospheric contributions and estimated melting depths decrease through time, corresponding to a higher degree of rifting. In the Kenyan dome, including the western rift, the degree of extension is low and lithospheric melting is the dominant source for basaltic magmatism. Mafic lavas from these regions have generally lower MgO but higher contents of alkalis, P2O5 and many incompatible trace elements than are observed in the Ethiopian Rift. High values of 87Sr/86Sr, 207Pb/204Pb and Zr/Hf relative to other parts of the EARS indicate melting of metasomatized lithosphere. Melting in this area occurs at depths up to 100+ km, consistent with the thick crustal section observed seismically. Between the topographic domes, basalts from the Turkana region record melting at shallow levels ( ˜35 km) consistent with seismic evidence for nearly complete rifting of the crustal section. The geochemistry of these lavas is dominated by asthenospheric source materials, with only minor lithospheric involvement. Temporal evolution of EARS geochemistry reflects progressive rifting of the thick craton. This change is manifest within lavas that are interpreted as plume-derived, as Tb/Yb values decrease from 30 Ma through the present. The modern thermal anomaly associated with Afar volcanism does not appear to extend below the shallow mantle, but may reflect a large blob of deep mantle material that became stuck to Africa 30 Ma and has contributed to regional volcanism ever since. Relative contributions from this deep mantle source, shallow asthenosphere and lithosphere are controlled by the extent of rifting and cannot be predicted solely on the basis of surface topography.

  3. Computed tomographic findings in 205 dogs with clinical signs compatible with middle ear disease: a retrospective study.

    PubMed

    Belmudes, Audrey; Pressanti, Charline; Barthez, Paul Y; Castilla-Castaño, Eloy; Fabries, Lionel; Cadiergues, Marie C

    2018-02-01

    Computed tomography (CT) is considered to be the reference method to evaluate middle ear structures. To evaluate the presence and severity of CT changes in the middle ear and establish if any specific clinical presentations are associated with otitis media. Medical records of animals referred for CT with history and clinical signs consistent with middle ear disease. Retrospective evaluation of CT examinations of tympanic bullae performed over a six year period. Medical records were reviewed for signalment, clinical signs and cytological evaluation of the external ear canal. Dogs were divided into three clinical groups: chronic otitis externa (Group 1), peripheral vestibular disorder (Group 2) and other clinical presentations (Group 3). Group 1 - Of 214 ears, 87 (40.7%) had CT abnormalities: 38 of 87 (17.7%) had material-filled bullae, 42 of 87 (19.6%) had thickened bullae walls and seven of 87 (3.2%) had lysis of the bulla. Abnormalities were significantly more frequent in dogs with suppurative otitis than in erythemato-ceruminous otitis (57% and 23%, respectively; P = 0.003). Proliferative otitis, particularly in French bulldogs, was associated with severe otitis media. Group 2 - Of the 106 ears, 91 (85.8%) had normal tympanic bullae. Group 3 - Of the 26 ears from deaf dogs, 17 had filled bullae; all nine affected dogs were Cavalier King Charles spaniels. All dogs with Claude Bernard Horner syndrome or head tilt had normal tympanic bullae. CT is useful for canine chronic otitis externa, particularly in suppurative or proliferative otitis, even in the absence of associated neurological signs. © 2017 ESVD and ACVD.

  4. Biomedical Application of Aerospace Personal Cooling Systems

    NASA Technical Reports Server (NTRS)

    Ku, Yu-Tsuan E.; Lee, Hank C.; Montgomery, Leslie D.; Webbon, Bruce W.; Kliss, Mark (Technical Monitor)

    1997-01-01

    Personal thermoregulatory systems which are used by astronauts to alleviate thermal stress during extravehicular activity have been applied to the therapeutic management of multiple sclerosis. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objectives of this study were to compare the effectiveness of two passive and two active cooling vests and to measure the body temperature and circulatory changes produced by each cooling vest configuration. The MicroClimate Systems and the Life Enhancement Tech(LET) lightweight liquid cooling vests, the Steele Vest and LET's Zipper Front Garment were used to cool the chest region of 10 male and female subjects (25 to 55 yr.) in this study. Calf, forearm and finger blood flows were measured using a tetrapolar impedance rheograph. The subjects, seated in an upright position at normal room temperature (approx.22C), were tested for 60 min. with the cooling system operated at its maximum cooling capacity. Blood flows were recorded continuously using a computer data acquisition system with a sampling frequency of 250 Hz. Oral, right and left ear temperatures and cooling system parameters were logged manually every 5 min. Arm, leg, chest and rectal temperatures; heart rate; respiration; and an activity index were recorded continuously on a U.F.I., Inc. Biolog ambulatory monitor. In general, the male and female subjects' oral and ear temperature responses to cooling were similar for all vest configurations tested. Oral temperatures during the recovery period were significantly (P<0.05) lower than during the control period, approx. 0.2 - 0.5C, for both men and women wearing any of the four different garments. The corresponding ear temperatures were significantly (P<0.05) decreased approx.0.2 - 0.4C by the end of the recovery period. Compared to the control period, no significant differences were found in rectal temperatures during cooling and recovery periods.

  5. A System Approach to Navy Medical Education and Training. Appendix 20. Ophthalmology Technician.

    DTIC Science & Technology

    1974-08-31

    PAGE 02 I OF RESDONSE BOOKLET I ISCRFN PATIENT O4 ARRIVAL TO DETERMINE WHICH STAFF MEMBER IPATIENT SHOULD SEE 2 ICHECK PUPIL REACTION TO LIGHT 3 IDILATE...PUPILS 4 IPALPATE EYi FOR INTRAOCULAR TENSION 5 IOBSERVE/RECORD OR DESCRIBE CHARACTERISTICS OF DRAINAGE FROM IEYES/EARS I 6 IOBSERVE FOR REPORT OR...RINGING, HEARI’iG ILOSS 1 38 !OBSERVE/RECORD OR DESCRIBE CHARACTERISTICS OF SI,ITUM, MUCUS 39 1EXAMINE FOR VIRAL INFECTIONS OF THE SKIN, E.G. AARTS 40

  6. An outbreak of streptococcosis in eared grebes (Podiceps nigricollis)

    USGS Publications Warehouse

    Jensen, Wayne I.

    1979-01-01

    An outbreak of streptococcosis (Streptococcus zooepidemicus), apparently the first recorded in wild birds, killed an estimated 7,500 eared grebes (Podiceps nigricollis) on Great Salt Lake (Utah) in November and December, 1977. Ducks and gulls feeding in the same area were unaffected.

  7. Allen's big-eared bat (Idionycteris phyllotis) documented in colorado based on recordings of its distinctive echolocation call

    USGS Publications Warehouse

    Hayes, M.A.; Navo, K.W.; Bonewell, L.; Mosch, C.J.; Adams, Rick A.

    2009-01-01

    Allen's big-eared bat (Idionycteris phyllotis) inhabits much of the southwestern USA, but has not been documented in Colorado. We recorded echolocation calls consistent with I. phyllotis near La Sal Creek, Montrose County, Colorado. Based on characteristics of echolocation calls and flight behavior, we conclude that the echolocation calls described here were emitted by I. phyllotis and that they represent the first documentation of this species in Colorado.

  8. Vestibular evoked myogenic potentials in patients with BPPV

    PubMed Central

    Korres, Stavros; Gkoritsa, Eleni; Giannakakou-Razelou, Dimitra; Yiotakis, Ioannis; Riga, Maria; Nikolpoulos, Thomas P.

    2011-01-01

    Summary Background The probable cause of Benign Paroxysmal Positional Vertigo (BPPV) is a degeneration of the oto lithic organs (utricle and saccule). The aim of the study is to find possible alterations in Vestibular Evoked Myogenic Potentials (VEMP) recordings in BPPV patients, because the saccule is part of the VEMP pathway. Material/Methods 27 BPPV patients (24 unilateral and 3 bilateral) aged 20 to 70 years and 30 healthy age matched controls. BPPV was diagnosed by the upbeating geotropic nystagmus found in the supine position with the head overextended towards one side. The subjects were investigated with pure tone audiometry, bi-thermal caloric test with electronystagmographic (ENG) recording, and VEMP recording. Results P1 latency and N1 latency did not present any statistical difference between control ears and affected ears of the BPPV population. The percentage of abnormal VEMP in the BPPV population was statistically higher than in the control ears (p<0.005). No significant relationship could be shown between the occurrence of Canal Paresis and abnormal VEMP. No relationship was found between the side (right or left ear) where BPPV appeared clinically and the side where abnormal VEMP was registered. Conclusions BPPV is a clinical entity associated with increased occurrence of abnormal VEMP recordings, possibly due to degeneration of the saccular macula, which is part of the neural VEMP pathway. PMID:21169909

  9. [Effect of the middle ear status on the recording of vestibular evoked myogenic potential--VEMP].

    PubMed

    Kurzyna, Agnieszka; Hassmann-Poznańska, Elzbieta; Topolska, Małgorzata Maria

    2004-01-01

    The aim of this study was to assess the effect of age on the recording of air- and bone-conducted vestibular evoked myogenic potential. Forty six young subjects were included in the study, ranging in age from 4 to 18 years. All of them underwent otoscopy, pure tone audiometry, tympanometry and air- and bone-conducted VEMP in response to click. Eighty six ears with normal hearing (pure tone average 20 dB) and type A and C1 tympanogram were studied. There were 2 groups according to age: group I--children aged 4-10 years--52 ears, group II--young subjects aged 11-18 years--34 ears. The threshold, the presence of correct waveform morphology of the response and the latency were evaluated. Above parameters were examined at 95 dB and 100 dB (nHL) air conducted click intensity and 60 dB (nHL) bone conducted click intensity. The age has no significant effect on the percentage of the recording of VEMP and the level of the response threshold with air stimulation, based on the performed studies. However, the age has effect on the prolongation of latency p13 and n23 both with air and bone stimulation. We paid attention to the lower percentage of the recording of bone-conducted VEMP in young subjects aged 11-18 years.

  10. Missing links in some curious auditory phenomena: a tale from the middle ear.

    PubMed

    Carpenter, Michelle S; Cacace, Anthony T; Mahoney, Marty J

    2012-02-01

    Broadband middle ear power reflectance (BMEPR) is an emerging noninvasive electroacoustic measure that evaluates transmission/reflection properties of the middle ear in high resolution. It is applicable over the entire age continuum and is rapid to perform. However, it remains to be determined if BMEPR is just an incremental step in the evolution of middle ear assessment or a major advance in the way middle ear function can be evaluated. To evaluate effects of age, gender, ear, and frequency on BMEPR measurements in adults without a history of middle ear disease and to assess whether these factors require consideration in test development; to review how these data may influence active physiologic process within the inner ear; to consider how they reconcile with previously published results; and to suggest applications for future research. Prospective, cross-sectional, multivariate analysis to evaluate the effects of age, gender, ear, and frequency on BMEPR in humans without a history of middle ear disease and no air-bone gaps exceeding 10 dB for any frequency. Fifty-six adults in two age groups (Group 1: 18-25 yr, n = 28; Group 2: ≥50 and <66 yr, n = 28). Each age group was stratified by ear and gender in a balanced design. Pure tone air conduction and bone-conduction audiometry was conducted in a commercial sound booth, using a clinical audiometer with standard earphones enclosed in supra-aural ear cushions, and a standard bone-conduction oscillator and headband to evaluate for air-bone gaps. Broadband middle ear power reflectance was measured using a calibrated, commercially available computer-controlled system that incorporated a high quality probe assembly to transduce stimuli and record acoustic responses from the ear canal. Data were analyzed with a four-way (2 × 2 × 2 × 16) repeated measures analysis-of-variance (ANOVA) to evaluate the effects of age group (young vs. old), gender (male vs. female), ear (left vs. right), and frequency (258 to 5040 Hz) on BMEPR. The ANOVA revealed a significant main effect of frequency. There were also gender × ear, gender × frequency, and age × gender × ear interactions. The three-way, age × gender × ear interaction captured the essence of results and revealed lowest power reflectance values in younger females and for right ears. This trend partially reversed in the older age group where higher power reflectance values were observed only in right ears of older females. The significant effects of age, gender, ear, and frequency on BMEPR parallel ear- and gender-related differences in hearing sensitivity, ear, and gender differences in the prevalence of spontaneous otoacoustic emissions (OAEs), gender differences in the magnitude of transient evoked OAEs, and ear differences in transient evoked contralateral OAE suppression effects reported in the literature. While original discussions of these aforementioned effects focused primarily on endocochlear and olivocochlear mechanisms, the BMEPR measurements reported herein suggest that middle ear transmission characteristics may also play a role. American Academy of Audiology.

  11. 15 CFR 758.1 - The Shipper's Export Declaration (SED) or Automated Export System (AES) record.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... that relate to EAR License Exceptions: (1) License Exception Baggage (BAG), as set forth in § 740.14 of.... See 15 CFR 30.53 of the FTSR; (5) License Exception Technology and Software Under Restriction (TSR... entered on the loading document (e.g., Cargo Declaration, manifest, bill of lading, (master) air waybill...

  12. 15 CFR 758.1 - The Shipper's Export Declaration (SED) or Automated Export System (AES) record.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... that relate to EAR License Exceptions: (1) License Exception Baggage (BAG), as set forth in § 740.14 of.... See 15 CFR 30.53 of the FTSR; (5) License Exception Technology and Software Under Restriction (TSR... entered on the loading document (e.g., Cargo Declaration, manifest, bill of lading, (master) air waybill...

  13. Fat-plug myringoplasty of ear lobule vs abdominal donor sites.

    PubMed

    Acar, Mustafa; Yazıcı, Demet; San, Turhan; Muluk, Nuray Bayar; Cingi, Cemal

    2015-04-01

    The purpose of this study is to compare the success rates of fat-graft myringoplasties harvesting adipose grafts from different donor sites (ear lobule vs abdomen). The clinical records of 61 patients (24 males and 37 females) who underwent fat-plug myringoplasty (FPM) were reviewed retrospectively. Fat from ear lobule (FEL) and abdominal fat were used as graft materials. The impact of age, gender, systemic diseases, topography of the perforation, utilization of fat graft materials of different origin on the tympanic membrane closure rate and the effect of FPM on hearing gain was analyzed. Our tympanic membrane (TM) closure rate was 82 %. No statistical significant difference was observed regarding age, gender, comorbidities (septal deviation, hypertension and diabetes mellitus) or habits (smoking). Posterior TM perforations had significantly lower healing rate. The change in TM closure rate considering different adipose tissue donor sites was not statistically significant. The hearing gain of the patients was mostly below 20 dB. Fat-plug myringoplasty (FPM) is a safe, cost-effective and easy operation for selected patients. Abdominal fat graft is as effective as ear lobe fat graft on tympanic membrane healing, has cosmetic advantages and should be taken into consideration when planning fat as the graft source.

  14. Inner Ear Drug Delivery for Auditory Applications

    PubMed Central

    Swan, Erin E. Leary; Mescher, Mark J.; Sewell, William F.; Tao, Sarah L.; Borenstein, Jeffrey T.

    2008-01-01

    Many inner ear disorders cannot be adequately treated by systemic drug delivery. A blood-cochlear barrier exists, similar physiologically to the blood-brain barrier, which limits the concentration and size of molecules able to leave the circulation and gain access to the cells of the inner ear. However, research in novel therapeutics and delivery systems has led to significant progress in the development of local methods of drug delivery to the inner ear. Intratympanic approaches, which deliver therapeutics to the middle ear, rely on permeation through tissue for access to the structures of the inner ear, whereas intracochlear methods are able to directly insert drugs into the inner ear. Innovative drug delivery systems to treat various inner ear ailments such as ototoxicity, sudden sensorineural hearing loss, autoimmune inner ear disease, and for preserving neurons and regenerating sensory cells are being explored. PMID:18848590

  15. Anatomy of the lamprey ear: morphological evidence for occurrence of horizontal semicircular ducts in the labyrinth of Petromyzon marinus

    USGS Publications Warehouse

    Maklad, Adel; Reed, Caitlyn; Johnson, Nicholas S.; Fritzsch, Bernd

    2014-01-01

    In jawed (gnathostome) vertebrates, the inner ears have three semicircular canals arranged orthogonally in the three Cartesian planes: one horizontal (lateral) and two vertical canals. They function as detectors for angular acceleration in their respective planes. Living jawless craniates, cyclostomes (hagfish and lamprey) and their fossil records seemingly lack a lateral horizontal canal. The jawless vertebrate hagfish inner ear is described as a torus or doughnut, having one vertical canal, and the jawless vertebrate lamprey having two. These observations on the anatomy of the cyclostome (jawless vertebrate) inner ear have been unchallenged for over a century, and the question of how these jawless vertebrates perceive angular acceleration in the yaw (horizontal) planes has remained open. To provide an answer to this open question we reevaluated the anatomy of the inner ear in the lamprey, using stereoscopic dissection and scanning electron microscopy. The present study reveals a novel observation: the lamprey has two horizontal semicircular ducts in each labyrinth. Furthermore, the horizontal ducts in the lamprey, in contrast to those of jawed vertebrates, are located on the medial surface in the labyrinth rather than on the lateral surface. Our data on the lamprey horizontal duct suggest that the appearance of the horizontal canal characteristic of gnathostomes (lateral) and lampreys (medial) are mutually exclusive and indicate a parallel evolution of both systems, one in cyclostomes and one in gnathostome ancestors.

  16. Anthropometric growth study of the ear in a Chinese population.

    PubMed

    Zhao, Shichun; Li, Dianguo; Liu, Zhenzhong; Wang, Yibiao; Liu, Lei; Jiang, Duyin; Pan, Bo

    2018-04-01

    A large number of anthropometric studies of the auricle have been reported in different nations, but little data were available in the Chinese population. The aim of this study was to analyze growth changes in the ear by measuring the width and length of ears in a Chinese population. A total of 480 participants were enrolled and classified into 1-, 3-, 5-, 7-, 9-, 12-, 14-, and 18-year groups (half were boys and half were girls in each group). Ear length, ear width, body weight, and body length were measured and recorded; ear index was calculated according to ear length and ear width. The growth of auricle and differences between genders were analyzed. Growth of ear in relation to body height and weight and the degree of emphasis on the length and width of the auricle were also analyzed. Ear length and width increased with age. Ear length achieved its mature size in both 14-year-old males and females. Ear width reached its mature size in males at 7 years and in females at 5 years. Different trends of ear index were shown between males and females. People in this population paid more attention to the length than the width of the auricle. The data indicated that ear development followed increase in age. There were gender and ethnic difference in the development of ear. These results may have potential implications for the diagnosis of congenital malformations, syndromes, and planning of ear reconstruction surgery. Copyright © 2017 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  17. Determining the distribution loss of brown eared-pheasant (Crossoptilon mantchuricum) using historical data and potential distribution estimates

    PubMed Central

    Song, Zitan

    2016-01-01

    We analyzed the synchronous relationship between forest cover and species distribution to explain the contraction in the distribution range of the brown eared-pheasant (Crossoptilon mantchuricum) in China. Historical resources can provide effective records for reconstructing long-term distribution dynamics. The brown eared-pheasant’s historical distribution from 25 to 1947 CE, which included the three provinces of Shaanxi, Shanxi, and Hebei based on this species’ habitat selection criteria, the history of the forests, ancient climate change records, and fossil data. The current species distribution covers Shaanxi, Shanxi, and Hebei provinces, as well as Beijing city, while Shanxi remains the center of the distribution area. MaxEnt model indicated that the suitable conditions of the brown eared-pheasant had retreated to the western regions of Shanxi and that the historical distribution area had reduced synchronously with the disappearance of local forest cover in Shanxi. We built a correlative relationship between the presence/absence of brown eared-pheasants and forest coverage and found that forest coverage in the north, northeast, central, and southeast areas of the Shanxi province were all less than 10% in 1911. Wild brown eared-pheasants are stable in the Luliang Mountains, where forest coverage reached 13.2% in 2000. Consequently, we concluded that the distribution of this species is primarily determined by vegetation conditions and that forest cover was the most significant determining factor. PMID:27781161

  18. Separating the contributions of olivocochlear and middle ear muscle reflexes in modulation of distortion product otoacoustic emission levels.

    PubMed

    Wolter, Nikolaus E; Harrison, Robert V; James, Adrian L

    2014-01-01

    Mediated by the medial olivocochlear system (MOCS), distortion product otoacoustic emission (DPOAE) levels are reduced by presentation of contralateral acoustic stimuli. Such acoustic signals can also evoke a middle ear muscle reflex (MEMR) that also attenuates recorded DPOAE levels. Our aim is to clearly differentiate these two inhibitory mechanisms and to analyze each separately, perhaps allowing the development of novel tests of hearing function. DPOAE were recorded in real time from chinchillas with normal auditory brainstem response thresholds and middle ear function. Amplitude reduction and its onset latency caused by contralateral presentation of intermittent narrow-band noise (NBN) were measured. Stapedius and tensor tympani muscle tendons were divided without disturbing the ossicular chain, and DPOAE testing was repeated. Peak reduction of (2f1 - f2) DPOAE levels occurred when the center frequency of contralateral NBN approximated the primary tone f2, indicating an f2-frequency-specific response. For a 4.5-kHz centered NBN, DPOAE (f2 = 4.4 kHz) inhibition was 0.1 dB (p < 0.001). This response remained present after tendon division, consistent with an MOCS origin. Low-frequency NBN (center frequency: 0.5 kHz) reduced otoacoustic emission levels (0.1 dB, p < 0.001) across a wide range of DPOAE frequencies. This low-frequency response was abolished by division of the middle ear muscle tendons, clearly indicating MEMR involvement. Following middle ear muscle tendon division, DPOAE inhibition by contralateral stimuli approximating the primary tone f2 persists, whereas responses evoked by lower contralateral frequencies are abolished. This distinguishes the different roles of the MOCS (f2 frequency specific) and MEMR (low frequency only) in contralateral modulation of DPOAE. This analysis helps clarify the pathways involved in an objective test that might have clinical benefit in the testing of neonates.

  19. Machine-learning prediction of cancer survival: a retrospective study using electronic administrative records and a cancer registry

    PubMed Central

    Gupta, Sunil; Tran, Truyen; Luo, Wei; Phung, Dinh; Kennedy, Richard Lee; Broad, Adam; Campbell, David; Kipp, David; Singh, Madhu; Khasraw, Mustafa; Matheson, Leigh; Ashley, David M; Venkatesh, Svetha

    2014-01-01

    Objectives Using the prediction of cancer outcome as a model, we have tested the hypothesis that through analysing routinely collected digital data contained in an electronic administrative record (EAR), using machine-learning techniques, we could enhance conventional methods in predicting clinical outcomes. Setting A regional cancer centre in Australia. Participants Disease-specific data from a purpose-built cancer registry (Evaluation of Cancer Outcomes (ECO)) from 869 patients were used to predict survival at 6, 12 and 24 months. The model was validated with data from a further 94 patients, and results compared to the assessment of five specialist oncologists. Machine-learning prediction using ECO data was compared with that using EAR and a model combining ECO and EAR data. Primary and secondary outcome measures Survival prediction accuracy in terms of the area under the receiver operating characteristic curve (AUC). Results The ECO model yielded AUCs of 0.87 (95% CI 0.848 to 0.890) at 6 months, 0.796 (95% CI 0.774 to 0.823) at 12 months and 0.764 (95% CI 0.737 to 0.789) at 24 months. Each was slightly better than the performance of the clinician panel. The model performed consistently across a range of cancers, including rare cancers. Combining ECO and EAR data yielded better prediction than the ECO-based model (AUCs ranging from 0.757 to 0.997 for 6 months, AUCs from 0.689 to 0.988 for 12 months and AUCs from 0.713 to 0.973 for 24 months). The best prediction was for genitourinary, head and neck, lung, skin, and upper gastrointestinal tumours. Conclusions Machine learning applied to information from a disease-specific (cancer) database and the EAR can be used to predict clinical outcomes. Importantly, the approach described made use of digital data that is already routinely collected but underexploited by clinical health systems. PMID:24643167

  20. Machine-learning prediction of cancer survival: a retrospective study using electronic administrative records and a cancer registry.

    PubMed

    Gupta, Sunil; Tran, Truyen; Luo, Wei; Phung, Dinh; Kennedy, Richard Lee; Broad, Adam; Campbell, David; Kipp, David; Singh, Madhu; Khasraw, Mustafa; Matheson, Leigh; Ashley, David M; Venkatesh, Svetha

    2014-03-17

    Using the prediction of cancer outcome as a model, we have tested the hypothesis that through analysing routinely collected digital data contained in an electronic administrative record (EAR), using machine-learning techniques, we could enhance conventional methods in predicting clinical outcomes. A regional cancer centre in Australia. Disease-specific data from a purpose-built cancer registry (Evaluation of Cancer Outcomes (ECO)) from 869 patients were used to predict survival at 6, 12 and 24 months. The model was validated with data from a further 94 patients, and results compared to the assessment of five specialist oncologists. Machine-learning prediction using ECO data was compared with that using EAR and a model combining ECO and EAR data. Survival prediction accuracy in terms of the area under the receiver operating characteristic curve (AUC). The ECO model yielded AUCs of 0.87 (95% CI 0.848 to 0.890) at 6 months, 0.796 (95% CI 0.774 to 0.823) at 12 months and 0.764 (95% CI 0.737 to 0.789) at 24 months. Each was slightly better than the performance of the clinician panel. The model performed consistently across a range of cancers, including rare cancers. Combining ECO and EAR data yielded better prediction than the ECO-based model (AUCs ranging from 0.757 to 0.997 for 6 months, AUCs from 0.689 to 0.988 for 12 months and AUCs from 0.713 to 0.973 for 24 months). The best prediction was for genitourinary, head and neck, lung, skin, and upper gastrointestinal tumours. Machine learning applied to information from a disease-specific (cancer) database and the EAR can be used to predict clinical outcomes. Importantly, the approach described made use of digital data that is already routinely collected but underexploited by clinical health systems.

  1. Tales of the Tape

    ERIC Educational Resources Information Center

    Glenn, David

    2006-01-01

    Research psychologists at the University of Texas are using electronically activated recorders (EARs) to study a range of human behavior, including romantic couples' dynamics, cross-cultural variations in sociability, and how students coped after the 9/11 attacks. The EAR studies, although still in their relative infancy, are generating striking…

  2. Topical Review: Families Coping With Child Trauma: A Naturalistic Observation Methodology

    PubMed Central

    Barrett, Anna; Bowles, Peter; Conroy, Rowena; Mehl, Matthias R.

    2016-01-01

    Objective To introduce a novel, naturalistic observational methodology (the Electronically Activated Recorder; EAR) as an opportunity to better understand the central role of the family environment in children’s recovery from trauma. Methods Discussion of current research methods and a systematic literature review of EAR studies on health and well-being. Results Surveys, experience sampling, and the EAR method each provide different opportunities and challenges for studying family interactions. We identified 17 articles describing relevant EAR studies. These investigated questions of emotional well-being, communicative behaviors, and interpersonal relationships, predominantly in adults. 5 articles reported innovative research in children, triangulating EAR-observed behavioral data (e.g., on child conflict at home) with neuroendocrine assay, sociodemographic information, and parent report. Finally, we discussed psychometric, practical, and ethical considerations for conducting EAR research with children and families. Conclusions Naturalistic observation methods such as the EAR have potential for pediatric psychology studies regarding trauma and the family environment. PMID:25797943

  3. Hearing of the African lungfish (Protopterus annectens) suggests underwater pressure detection and rudimentary aerial hearing in early tetrapods.

    PubMed

    Christensen, Christian Bech; Christensen-Dalsgaard, Jakob; Madsen, Peter Teglberg

    2015-02-01

    In the transition from an aquatic to a terrestrial lifestyle, vertebrate auditory systems have undergone major changes while adapting to aerial hearing. Lungfish are the closest living relatives of tetrapods and their auditory system may therefore be a suitable model of the auditory systems of early tetrapods such as Acanthostega. Therefore, experimental studies on the hearing capabilities of lungfish may shed light on the possible hearing capabilities of early tetrapods and broaden our understanding of hearing across the water-to-land transition. Here, we tested the hypotheses that (i) lungfish are sensitive to underwater pressure using their lungs as pressure-to-particle motion transducers and (ii) lungfish can detect airborne sound. To do so, we used neurophysiological recordings to estimate the vibration and pressure sensitivity of African lungfish (Protopterus annectens) in both water and air. We show that lungfish detect underwater sound pressure via pressure-to-particle motion transduction by air volumes in their lungs. The morphology of lungfish shows no specialized connection between these air volumes and the inner ears, and so our results imply that air breathing may have enabled rudimentary pressure detection as early as the Devonian era. Additionally, we demonstrate that lungfish in spite of their atympanic middle ear can detect airborne sound through detection of sound-induced head vibrations. This strongly suggests that even vertebrates with no middle ear adaptations for aerial hearing, such as the first tetrapods, had rudimentary aerial hearing that may have led to the evolution of tympanic middle ears in recent tetrapods. © 2015. Published by The Company of Biologists Ltd.

  4. Human otoacariasis.

    PubMed

    Somayaji, K S Gangadhara; Rajeshwari, A

    2007-09-01

    Accidental entry of foreign bodies into the ear canal is very common. Animate foreign bodies constitute upto 14% of cases, majority being the cockroaches. Not many cases of ticks entering into human ears are found in the scientific literature. Even the available reports are from South Africa, Nepal, Malaysia, Chile and Srilanka. This Indian study discusses the occurence, clinical features, the methods adopted in the removal and the complications of tick infestation of human ear. A total of 144 cases of ticks entering the human ears were studied over a period of two years from Jan 2004 to Dec 2005. This report represents one of the largest recorded series of human otoacariasis available in the Indian literature.

  5. Unilateral hearing during development: hemispheric specificity in plastic reorganizations

    PubMed Central

    Kral, Andrej; Heid, Silvia; Hubka, Peter; Tillein, Jochen

    2013-01-01

    The present study investigates the hemispheric contributions of neuronal reorganization following early single-sided hearing (unilateral deafness). The experiments were performed on ten cats from our colony of deaf white cats. Two were identified in early hearing screening as unilaterally congenitally deaf. The remaining eight were bilaterally congenitally deaf, unilaterally implanted at different ages with a cochlear implant. Implanted animals were chronically stimulated using a single-channel portable signal processor for two to five months. Microelectrode recordings were performed at the primary auditory cortex under stimulation at the hearing and deaf ear with bilateral cochlear implants. Local field potentials (LFPs) were compared at the cortex ipsilateral and contralateral to the hearing ear. The focus of the study was on the morphology and the onset latency of the LFPs. With respect to morphology of LFPs, pronounced hemisphere-specific effects were observed. Morphology of amplitude-normalized LFPs for stimulation of the deaf and the hearing ear was similar for responses recorded at the same hemisphere. However, when comparisons were performed between the hemispheres, the morphology was more dissimilar even though the same ear was stimulated. This demonstrates hemispheric specificity of some cortical adaptations irrespective of the ear stimulated. The results suggest a specific adaptation process at the hemisphere ipsilateral to the hearing ear, involving specific (down-regulated inhibitory) mechanisms not found in the contralateral hemisphere. Finally, onset latencies revealed that the sensitive period for the cortex ipsilateral to the hearing ear is shorter than that for the contralateral cortex. Unilateral hearing experience leads to a functionally-asymmetric brain with different neuronal reorganizations and different sensitive periods involved. PMID:24348345

  6. Unilateral hearing during development: hemispheric specificity in plastic reorganizations.

    PubMed

    Kral, Andrej; Heid, Silvia; Hubka, Peter; Tillein, Jochen

    2013-01-01

    The present study investigates the hemispheric contributions of neuronal reorganization following early single-sided hearing (unilateral deafness). The experiments were performed on ten cats from our colony of deaf white cats. Two were identified in early hearing screening as unilaterally congenitally deaf. The remaining eight were bilaterally congenitally deaf, unilaterally implanted at different ages with a cochlear implant. Implanted animals were chronically stimulated using a single-channel portable signal processor for two to five months. Microelectrode recordings were performed at the primary auditory cortex under stimulation at the hearing and deaf ear with bilateral cochlear implants. Local field potentials (LFPs) were compared at the cortex ipsilateral and contralateral to the hearing ear. The focus of the study was on the morphology and the onset latency of the LFPs. With respect to morphology of LFPs, pronounced hemisphere-specific effects were observed. Morphology of amplitude-normalized LFPs for stimulation of the deaf and the hearing ear was similar for responses recorded at the same hemisphere. However, when comparisons were performed between the hemispheres, the morphology was more dissimilar even though the same ear was stimulated. This demonstrates hemispheric specificity of some cortical adaptations irrespective of the ear stimulated. The results suggest a specific adaptation process at the hemisphere ipsilateral to the hearing ear, involving specific (down-regulated inhibitory) mechanisms not found in the contralateral hemisphere. Finally, onset latencies revealed that the sensitive period for the cortex ipsilateral to the hearing ear is shorter than that for the contralateral cortex. Unilateral hearing experience leads to a functionally-asymmetric brain with different neuronal reorganizations and different sensitive periods involved.

  7. Neural tuning matches frequency-dependent time differences between the ears

    PubMed Central

    Benichoux, Victor; Fontaine, Bertrand; Franken, Tom P; Karino, Shotaro; Joris, Philip X; Brette, Romain

    2015-01-01

    The time it takes a sound to travel from source to ear differs between the ears and creates an interaural delay. It varies systematically with spatial direction and is generally modeled as a pure time delay, independent of frequency. In acoustical recordings, we found that interaural delay varies with frequency at a fine scale. In physiological recordings of midbrain neurons sensitive to interaural delay, we found that preferred delay also varies with sound frequency. Similar observations reported earlier were not incorporated in a functional framework. We find that the frequency dependence of acoustical and physiological interaural delays are matched in key respects. This suggests that binaural neurons are tuned to acoustical features of ecological environments, rather than to fixed interaural delays. Using recordings from the nerve and brainstem we show that this tuning may emerge from neurons detecting coincidences between input fibers that are mistuned in frequency. DOI: http://dx.doi.org/10.7554/eLife.06072.001 PMID:25915620

  8. Real-ear acoustical characteristics of impulse sound generated by golf drivers and the estimated risk to hearing: a cross-sectional study.

    PubMed

    Zhao, Fei; Bardsley, Barry

    2014-01-21

    This study investigated real-ear acoustical characteristics in terms of the sound pressure levels (SPLs) and frequency responses in situ generated from golf club drivers at impact with a golf ball. The risk of hearing loss caused by hitting a basket of golf balls using various drivers was then estimated. Cross-sectional study. The three driver clubs were chosen on the basis of reflection of the commonality and modern technology of the clubs. The participants were asked to choose the clubs in a random order and hit six two-piece range golf balls with each club. The experiment was carried out at a golf driving range in South Wales, UK. 19 male amateur golfers volunteered to take part in the study, with an age range of 19-54 years. The frequency responses and peak SPLs in situ of the transient sound generated from the club at impact were recorded bilaterally and simultaneously using the GN Otometric Freefit wireless real-ear measurement system. A swing speed radar system was also used to investigate the relationship between noise level and swing speed. Different clubs generated significantly different real-ear acoustical characteristics in terms of SPL and frequency responses. However, they did not differ significantly between the ears. No significant correlation was found between the swing speed and noise intensity. On the basis of the SPLs measured in the present study, the percentage of daily noise exposure for hitting a basket of golf balls using the drivers described above was less than 2%. The immediate danger of noise-induced hearing loss for amateur golfers is quite unlikely. However, it may be dangerous to hearing if the noise level generated by the golf clubs exceeded 116 dBA.

  9. Age- and Gender-Specific Normative Information from Children Assessed with a Dichotic Words Test.

    PubMed

    Moncrieff, Deborah

    2015-01-01

    The most widely used assessment in the clinical auditory processing disorder (APD) battery is the dichotic listening test. New tests with normative information are helpful for assessment and cross-check of results for reliable diagnosis. The Dichotic Words Test was developed for use in the clinical test battery for diagnosis of APD. The test stimuli were common single syllable words matched for average root-mean-square amplitude and each pair was temporally aligned at both onset and offset. The study was conducted to collect performance results from typically developing children to create normative information for the test. The study follows a cross-sectional design. Typically developing children (n = 416) between the ages of 5 and 12 yr were recruited from schools in the community. There were 217 males and 199 females in the study sample. Only children who passed a hearing screening were eligible to participate. Scores for each ear were recorded during administration of the first free recall version of the test. Ear advantages based on results recorded for left and right ears were used to measure prevalence of right, left, and no ear advantages. Results for each listener's dominant and non-dominant ears and the absolute difference between them were put into the data analysis. Results were analyzed for normality and because no results were normally distributed, all further analyses were done with nonparametric statistical tests. Normative data for dominant and non-dominant ear scores and ear advantages were determined at the 95% confidence interval through bootstrapping methods with 1,000 samples. Children were divided into four age groups based on results in their dominant ears. Females generally performed better than males and the prevalence of a right-ear advantage was ∼60% across all children tested. Normative lower-bound cut-off scores were established for males and females within each age group for dominant and non-dominant ear scores. Normative upper-bound cut-off scores were established for males and females within each age group for ear advantage scores. Normative information specific to age group and gender will be useful in clinical assessment for APD. Prevalence of left-ear advantage results in the sample may have been partly due to uncontrolled influences of voice-onset time in arranging the dichotic pairs. American Academy of Audiology.

  10. Comparison of packing material in an animal model of middle ear trauma.

    PubMed

    Perez, Enrique; Hachem, Ralph Abi; Carlton, Daniel; Bueno, Isabel; Vernon, Stephen; Van De Water, Thomas R; Angeli, Simon I

    2016-01-01

    To compare the performance of absorbable gelatin sponge (AGS) with polyurethane foam (PUF) as middle ear packing material after mucosal trauma. Using a randomized, controlled and blinded study design fifteen guinea pigs underwent middle ear surgery with mucosal trauma performed on both ears. One ear was packed with either PUF or AGS while the contralateral ear remained untreated and used as non-packed paired controls. Auditory brainstem response (ABR) thresholds were measured pre-operatively and repeated at 1, 2, and 6weeks postoperatively. Histological analysis of middle ear mucosa was done in each group to evaluate the inflammatory reaction and wound healing. Another eighteen animals underwent middle ear wounding and packing in one ear while the contralateral ear was left undisturbed as control. Twelve guinea pigs were euthanized at 2weeks postoperatively, and six were euthanized at 3days post-operatively. Mucosal samples were collected for analysis of TGF-β1 levels by enzyme-linked immunosorbent assay. ABR recordings demonstrate that threshold level changes from baseline were minor in PUF packed and control ears. Threshold levels were higher in the AGS packed ears compared with both control and PUF packed ears for low frequency stimuli. Histological analysis showed persistence of packing material at 6weeks postoperatively, inflammation, granulation tissue formation, foreign body reaction and neo-osteogenesis in both AGS and PUF groups. TGF-β1 protein levels did not differ between groups. PUF and AGS packing cause inflammation and neo-osteogenesis in the middle ear following wounding of the mucosa and packing. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Distortion product otoacoustic emissions provide clues to hearing mechanisms in the frog ear

    NASA Astrophysics Data System (ADS)

    Vassilakis, Pantelis N.; Meenderink, Sebastiaan W. F.; Narins, Peter M.

    2004-12-01

    2 f1-f2 and 2 f2-f1 distortion product otoacoustic emissions (DPOAEs) were recorded from both ears of male and female Rana pipiens pipiens and Rana catesbeiana. The input-output (I/O) curves obtained from the amphibian papilla (AP) of both frog species are analogous to I/O curves recorded from mammals suggesting that, similarly to the mammalian cochlea, there may be an amplification process present in the frog AP. DPOAE level dependence on L1-L2 is different from that in mammals and consistent with intermodulation distortion expectations. Therefore, if a mechanical structure in the frog inner ear is functioning analogously to the mammalian basilar membrane, it must be more broadly tuned. DPOAE audiograms were obtained for primary frequencies spanning the animals' hearing range and selected stimulus levels. The results confirm that DPOAEs are produced in both papillae, with R. catesbeiana producing stronger emissions than R. p. pipiens. Consistent with previously reported sexual dimorphism in the mammalian and anuran auditory systems, females of both species produce stronger emissions than males. Moreover, it appears that 2 f1-f2 in the frog is generated primarily at the DPOAE frequency place, while 2 f2-f1 is generated primarily at a frequency place around the primaries. Regardless of generation place, both emissions within the AP may be subject to the same filtering mechanism, possibly the tectorial membrane..

  12. Anatomy, Physiology and Function of the Auditory System

    NASA Astrophysics Data System (ADS)

    Kollmeier, Birger

    The human ear consists of the outer ear (pinna or concha, outer ear canal, tympanic membrane), the middle ear (middle ear cavity with the three ossicles malleus, incus and stapes) and the inner ear (cochlea which is connected to the three semicircular canals by the vestibule, which provides the sense of balance). The cochlea is connected to the brain stem via the eighth brain nerve, i.e. the vestibular cochlear nerve or nervus statoacusticus. Subsequently, the acoustical information is processed by the brain at various levels of the auditory system. An overview about the anatomy of the auditory system is provided by Figure 1.

  13. 15 CFR 762.4 - Original records required.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... to rely on that record to meet the recordkeeping requirements of the EAR, that person must retain the... print out of the complete document is deemed to be an original record for purposes of this section. [61...

  14. 15 CFR 762.4 - Original records required.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... to rely on that record to meet the recordkeeping requirements of the EAR, that person must retain the... print out of the complete document is deemed to be an original record for purposes of this section. [61...

  15. 15 CFR 762.4 - Original records required.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... to rely on that record to meet the recordkeeping requirements of the EAR, that person must retain the... print out of the complete document is deemed to be an original record for purposes of this section. [61...

  16. 15 CFR 762.4 - Original records required.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... to rely on that record to meet the recordkeeping requirements of the EAR, that person must retain the... print out of the complete document is deemed to be an original record for purposes of this section. [61...

  17. Otologic Manifestations of Autosomal Recessive Congenital Ichthyosis in Children.

    PubMed

    Martín-Santiago, A; Rodríguez-Pascual, M; Knöpfel, N; Hernández-Martín, Á

    2015-11-01

    Few studies have investigated ear involvement in nonsyndromic autosomal recessive congenital ichthyosis (ARCI). To assess the type and frequency of otologic manifestations of ARCI in patients under follow-up at the pediatric dermatology department of our hospital. We prospectively studied the presence of ear pain, ear itching, tinnitus, otitis, cerumen impaction, accumulation of epithelial debris, and hearing loss. Daily hygiene measures, topical treatments, medical-surgical interventions, and frequency of visits to an ear, nose, and throat (ENT) specialist were noted in the patients' medical records. Ear examination and hearing tests were performed in all cases. Ten patients were studied: 2 had a self-healing collodion baby phenotype and 8 had ichthyosis. There was mention of otologic manifestations in the records of all 8 patients with ichthyosis (100%); 6 of these patients (75%) had abnormalities in the external auditory canal examination and 2 (25%) had conductive hearing loss. Our findings are limited by the small number of patients studied, all of whom were younger than 19 years. The involvement of both dermatologists and ENT specialists in the management of patients with ichthyosis is crucial to ensure the application of the best therapeutic and preventive measures. More studies are needed to assess the prevalence and impact on quality of life of ear involvement in patients with ichthyosis and to determine the optimal interval between ENT visits for these patients. Copyright © 2015 Elsevier España, S.L.U. and AEDV. All rights reserved.

  18. Dual instrument passive acoustic monitoring of belugas in Cook Inlet, Alaska.

    PubMed

    Castellote, Manuel; Small, Robert J; Lammers, Marc O; Jenniges, Justin J; Mondragon, Jeff; Atkinson, Shannon

    2016-05-01

    As part of a long-term research program, Cook Inlet beluga (Delphinapterus leucas) presence was acoustically monitored with two types of acoustic sensors utilized in tandem in moorings deployed year-round: an ecological acoustic recorder (EAR) and a cetacean and porpoise detector (C-POD). The EAR was used primarily to record the calls, whistles, and buzzes produced by belugas and killer whales (Orcinus orca). The C-POD was used to log and classify echolocation clicks from belugas, killer whales, and porpoises. This paper describes mooring packages that maximized the chances of successful long-term data collection in the particularly challenging Cook Inlet environment, and presents an analytical comparison of odontocete detections obtained by the collocated EAR and C-POD instruments from two mooring locations in the upper inlet. Results from this study illustrate a significant improvement in detecting beluga and killer whale presence when the different acoustic signals detected by EARs and C-PODs are considered together. Further, results from concurrent porpoise detections indicating prey competition and feeding interference with beluga, and porpoise displacement due to ice formation are described.

  19. Underwater hearing and sound localization with and without an air interface.

    PubMed

    Shupak, Avi; Sharoni, Zohara; Yanir, Yoav; Keynan, Yoav; Alfie, Yechezkel; Halpern, Pinchas

    2005-01-01

    Underwater hearing acuity and sound localization are improved by the presence of an air interface around the pinnae and inside the external ear canals. Hearing threshold and the ability to localize sound sources are reduced underwater. The resonance frequency of the external ear is lowered when the external ear canal is filled with water, and the impedance-matching ability of the middle ear is significantly reduced due to elevation of the ambient pressure, the water-mass load on the tympanic membrane, and the addition of a fluid-air interface during submersion. Sound lateralization on land is largely explained by the mechanisms of interaural intensity differences and interaural temporal or phase differences. During submersion, these differences are largely lost due to the increase in underwater sound velocity and cancellation of the head's acoustic shadow effect because of the similarity between the impedance of the skull and the surrounding water. Ten scuba divers wearing a regular opaque face mask or an opaque ProEar 2000 (Safe Dive, Ltd., Hofit, Israel) mask that enables the presence of air at ambient pressure in and around the ear made a dive to a depth of 3 m in the open sea. Four underwater speakers arranged on the horizontal plane at 90-degree intervals and at a distance of 5 m from the diver were used for testing pure-tone hearing thresholds (PTHT), the reception threshold for the recorded sound of a rubber-boat engine, and sound localization. For sound localization, the sound of the rubber boat's engine was randomly delivered by one speaker at a time at 40 dB HL above the recorded sound of a rubber-boat engine, and the diver was asked to point to the sound source. The azimuth was measured by the diver's companion using a navigation board. Underwater PTHT with both masks were significantly higher for frequencies of 250 to 6000 Hz when compared with the thresholds on land (p <0.0001). No differences were found in the PTHT or the reception threshold for the recorded sound of a rubber-boat engine for dry or wet ear conditions. There was no difference in the sound localization error between the regular mask and the ProEar 2000 mask. The presence of air around the pinna and inside the external ear canal did not improve underwater hearing sensitivity or sound localization. These results support the argument that bone conduction plays the main role in underwater hearing.

  20. Ear pain and its treatment in hypobaric chamber training in the Japan Air Self-Defense Force.

    PubMed

    Ohrui, Nobuhiro; Takeuchi, Akihiko; Tong, Andrew; Iwata, Masashi

    2008-06-01

    We have documented that ear pain is the most prevalent physiologic incident during hypobaric chamber training in the Japan Air Self-Defense Force. Ear pain may increase also in flight in the future because it is closely related to allergic rhinitis. Therefore, it is very important to know the characteristic of ear pain and the efficacy of its treatment. The incidence of ear pain was calculated in each training profile from 1990 to 1998. Type III chamber flight records were further analyzed for the characteristics of ear pain: relationship with a trainee occupational category, time of occurrence of ear pain, and efficacy of treatment. Of 17,935 exposures, 740 trainees (4.1%) had ear pain. Of 7,047 trainees, 429 (6.1%) complained of ear pain especially in Type III, totaling 625 times. Fighter pilots and cargo pilots complained of ear pain one twelfth and one third the number of times, respectively, compared with passengers. Of the 625 episodes, 616 (98.6%) occurred during descent. Three kinds of treatment were administered until the pain was relieved in the following order: Valsalva maneuver, Politzer bag, and decompression. The efficacy rates were 35.8, 92.3, and 83.9%, respectively. Only 5 trainees (0.07%) could not complete training due to ear pain despite treatment. The combination treatment of Valsalva maneuver, Politzer bag, and decompression is very effective for relieving ear pain encountered during hypobaric chamber training. A health specialist needs to understand ear pain and its treatment in hypobaric environment such as aircraft.

  1. Sturge-Weber syndrome: ear, nose, and throat issues and neurologic status.

    PubMed

    Irving, Natasha D; Lim, Jae Hyung; Cohen, Bernard; Ferenc, Lisa M; Comi, Anne M

    2010-10-01

    The pathophysiology of Sturge-Weber syndrome is poorly understood, and ear, nose, and throat involvement is possible. These issues can result in frequent illnesses or airway obstruction, affecting patients' neurologic status. Patients with definite brain involvement who reported potential ear, nose, and throat issues on intake questionnaires underwent retrospective reviews of their medical records. We examined the relationships between these issues, secondary surgical interventions, and patients' neurologic status. The most common complaints involved the sinuses and frequent ear infections. Six patients underwent placement of ear tubes, leading to improvements in migraines and stroke-like episodes in one patient, and improved seizure control in four others. Obstructive sleep apnea was confirmed in three patients who underwent sleep studies. Tonsil or adenoid removal occurred in another three patients. Surgery resulted in marked improvements regarding excessive drooling, daytime sleepiness, and breathing problems. These findings suggest that ear, nose, and throat problems occur frequently in patients with Sturge-Weber Syndrome, and when repeated ear infections are associated with uncontrolled seizures, early placement of ear tubes may be beneficial. Furthermore, patients with facial tissue hypertrophy may be at risk for obstructive sleep apnea, and should be appropriately evaluated. Copyright © 2010 Elsevier Inc. All rights reserved.

  2. Audiometric Predictions Using SFOAE and Middle-Ear Measurements

    PubMed Central

    Ellison, John C.; Keefe, Douglas H.

    2006-01-01

    Objective The goals of the study are to determine how well stimulus-frequency otoacoustic emissions (SFOAEs) identify hearing loss, classify hearing loss as mild or moderate-severe, and correlate with pure-tone thresholds in a population of adults with normal middle-ear function. Other goals are to determine if middle-ear function as assessed by wideband acoustic transfer function (ATF) measurements in the ear canal account for the variability in normal thresholds, and if the inclusion of ATFs improves the ability of SFOAEs to identify hearing loss and predict pure-tone thresholds. Design The total suppressed SFOAE signal and its corresponding noise were recorded in 85 ears (22 normal ears and 63 ears with sensorineural hearing loss) at octave frequencies from 0.5 – 8 kHz using a nonlinear residual method. SFOAEs were recorded a second time in three impaired ears to assess repeatability. Ambient-pressure ATFs were obtained in all but one of these 85 ears, and were also obtained from an additional 31 normal-hearing subjects in whom SFOAE data were not obtained. Pure-tone air-and bone-conduction thresholds and 226-Hz tympanograms were obtained on all subjects. Normal tympanometry and the absence of air-bone gaps were used to screen subjects for normal middle-ear function. Clinical decision theory was used to assess the performance of SFOAE and ATF predictors in classifying ears as normal or impaired, and linear regression analysis was used to test the ability of SFOAE and ATF variables to predict the air-conduction audiogram. Results The ability of SFOAEs to classify ears as normal or hearing impaired was significant at all test frequencies. The ability of SFOAEs to classify impaired ears as either mild or moderate-severe was significant at test frequencies from 0.5 to 4 kHz. SFOAEs were present in cases of severe hearing loss. SFOAEs were also significantly correlated with air-conduction thresholds from 0.5 to 8 kHz. The best performance occurred using the SFOAE signal-to-noise ratio (S/N) as the predictor, and the overall best performance was at 2 kHz. The SFOAE S/N measures were repeatable to within 3.5 dB in impaired ears. The ATF measures explained up to 25% of the variance in the normal audiogram; however, ATF measures did not improve SFOAEs predictors of hearing loss except at 4 kHz. Conclusions In common with other OAE types, SFOAEs are capable of identifying the presence of hearing loss. In particular, SFOAEs performed better than distortion-product and click-evoked OAEs in predicting auditory status at 0.5 kHz; SFOAE performance was similar to that of other OAE types at higher frequencies except for a slight performance reduction at 4 kHz. Because SFOAEs were detected in ears with mild to severe cases of hearing loss they may also provide an estimate of the classification of hearing loss. Although SFOAEs were significantly correlated with hearing threshold, they do not appear to have clinical utility in predicting a specific behavioral threshold. Information on middle-ear status as assessed by ATF measures offered minimal improvement in SFOAE predictions of auditory status in a population of normal and impaired ears with normal middle-ear function. However, ATF variables did explain a significant fraction of the variability in the audiograms of normal ears, suggesting that audiometric thresholds in normal ears are partially constrained by middle-ear function as assessed by ATF tests. PMID:16230898

  3. Clearance by the mucociliary system in 'simple chronic otitis media'.

    PubMed

    Hadas, E; Sadé, J

    1979-08-01

    This is a study of the rate of middle ear clearance in chronic otitis media and atelectatic ears. The clearance rate was measured with the aid of non-soluble saccharin, introduced into the middle ear through an existing perforation in 'chronic ears', or through a ventilating tube in atelectatic ears. Cholesteatomatous ears were excluded. Altogether 122 ears were examined and about two-thirds of the subjects felt the sweet taste in their mouths thereafter. The average time it took for the saccharin to be transported from the middle ear to the taste buds was 33' 22" minutes in non-infected (i.e. dry) chronic ears (38 patients or 66 per cent). Wet or infected ears with chronic otitis media (30 patients, or 58 per cent) showed a slower transport rate, averaging 54' 22" minutes--the difference was significant at the 0.01 level. 8 (63 per cent) of the atelectatic ears transported the saccharin at an average rate of 50' 25". This study demonstrated that most ears with 'simple' chronic otitis media and atelectatic ears have a patent eustachian tube and that their mucociliary system can transport foreign particles through it. When the ear is infected, transport tends to be slowed down.

  4. Earless toads sense low frequencies but miss the high notes.

    PubMed

    Womack, Molly C; Christensen-Dalsgaard, Jakob; Coloma, Luis A; Chaparro, Juan C; Hoke, Kim L

    2017-10-11

    Sensory losses or reductions are frequently attributed to relaxed selection. However, anuran species have lost tympanic middle ears many times, despite anurans' use of acoustic communication and the benefit of middle ears for hearing airborne sound. Here we determine whether pre-existing alternative sensory pathways enable anurans lacking tympanic middle ears (termed earless anurans) to hear airborne sound as well as eared species or to better sense vibrations in the environment. We used auditory brainstem recordings to compare hearing and vibrational sensitivity among 10 species (six eared, four earless) within the Neotropical true toad family (Bufonidae). We found that species lacking middle ears are less sensitive to high-frequency sounds, however, low-frequency hearing and vibrational sensitivity are equivalent between eared and earless species. Furthermore, extratympanic hearing sensitivity varies among earless species, highlighting potential species differences in extratympanic hearing mechanisms. We argue that ancestral bufonids may have sufficient extratympanic hearing and vibrational sensitivity such that earless lineages tolerated the loss of high frequency hearing sensitivity by adopting species-specific behavioural strategies to detect conspecifics, predators and prey. © 2017 The Author(s).

  5. Topical Review: Families Coping With Child Trauma: A Naturalistic Observation Methodology.

    PubMed

    Alisic, Eva; Barrett, Anna; Bowles, Peter; Conroy, Rowena; Mehl, Matthias R

    2016-01-01

    To introduce a novel, naturalistic observational methodology (the Electronically Activated Recorder; EAR) as an opportunity to better understand the central role of the family environment in children's recovery from trauma. Discussion of current research methods and a systematic literature review of EAR studies on health and well-being. Surveys, experience sampling, and the EAR method each provide different opportunities and challenges for studying family interactions. We identified 17 articles describing relevant EAR studies. These investigated questions of emotional well-being, communicative behaviors, and interpersonal relationships, predominantly in adults. 5 articles reported innovative research in children, triangulating EAR-observed behavioral data (e.g., on child conflict at home) with neuroendocrine assay, sociodemographic information, and parent report. Finally, we discussed psychometric, practical, and ethical considerations for conducting EAR research with children and families. Naturalistic observation methods such as the EAR have potential for pediatric psychology studies regarding trauma and the family environment. © The Author 2015. Published by Oxford University Press on behalf of the Society of Pediatric Psychology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  6. Ultrasound characterization of middle ear effusion.

    PubMed

    Seth, Rahul; Discolo, Christopher M; Palczewska, Grazyna M; Lewandowski, Jan J; Krakovitz, Paul R

    2013-01-01

    To further enhance and assess the ability to characterize middle ear effusion (MEE) using non-invasive ultrasound technology. This is a prospective unblinded comparison study. Fifty-six children between the ages of 6 months and 17 years scheduled to undergo bilateral myringotomy with pressure equalization tube placement were enrolled. With the child anesthetized, the probe was placed into the external ear canal after sterile water was inserted. Ultrasound recordings of middle ear contents were analyzed by computer algorithm. Middle ear fluid was collected during myringotomy and analyzed for bacterial culture and viscosity. Ultrasound waveforms yielded a computer algorithm interpretation of middle ear contents in 66% of ears tested. When a result was obtained, the sensitivity and specificity for successfully characterizing middle ear fluid content as either void of fluid, thick fluid (mucoid), or thin fluid (serous or purulent) were at least 94%. Mucoid effusions had higher measured viscosity values (P=.002). Viscosity measures were compared to culture result, and those with low viscosity (thin consistency) had a higher likelihood of having a positive culture (P=.048). The device sensitivity and specificity for fluid detection were 94% or greater among interpretable waveforms (66% of those tested). Although this technology provides important information of the middle ear effusion presence and characteristic, further technological improvements are needed. Copyright © 2013 Elsevier Inc. All rights reserved.

  7. Ultrasound Characterization of Middle Ear Effusion

    PubMed Central

    Seth, Rahul; Discolo, Christopher M; Palczewska, Grazyna M; Lewandowski, Jan J; Krakovitz, Paul R

    2012-01-01

    Purpose To further enhance and assess the ability to characterize middle ear effusion (MEE) using non-invasive ultrasound technology. Materials and Methods This is a prospective unblinded comparison study. Fifty-six children between the ages of 6 months and 17 years scheduled to undergo bilateral myringotomy with pressure equalization tube placement were enrolled. With the child anesthetized, the probe was placed into the external ear canal after sterile water was inserted. Ultrasound recordings of middle ear contents were analyzed by computer algorithm. Middle ear fluid was collected during myringotomy and analyzed for bacterial culture and viscosity. Results Ultrasound waveforms yielded a computer algorithm interpretation of middle ear contents in 66% of ears tested. When a result was obtained, the sensitivity and specificity for successfully characterizing middle ear fluid content as either void of fluid, thick fluid (mucoid), or thin fluid (serous or purulent) was at least 94%. Mucoid effusions had higher measured viscosity values (P=0.002). Viscosity measures were compared to culture result, and those with low viscosity (thin consistency) had a higher likelihood of having a positive culture (P=0.048). Conclusion The device sensitivity and specificity for fluid detection was 94% or greater among interpretable waveforms (66% of those tested). Although this technology provides important information of the middle ear effusion presence and characteristic, further technological improvements are needed. PMID:23084430

  8. Pneumatic low-coherence interferometry otoscope to quantify tympanic membrane mobility and middle ear pressure.

    PubMed

    Won, Jungeun; Monroy, Guillermo L; Huang, Pin-Chieh; Dsouza, Roshan; Hill, Malcolm C; Novak, Michael A; Porter, Ryan G; Chaney, Eric; Barkalifa, Ronit; Boppart, Stephen A

    2018-02-01

    Pneumatic otoscopy to assess the mobility of the tympanic membrane (TM) is a highly recommended diagnostic method of otitis media (OM), a widespread middle ear infection characterized by the fluid accumulation in the middle ear. Nonetheless, limited depth perception and subjective interpretation of small TM displacements have challenged the appropriate and efficient examination of TM dynamics experienced during OM. In this paper, a pneumatic otoscope integrated with low coherence interferometry (LCI) was adapted with a controlled pressure-generating system to record the pneumatic response of the TM and to estimate middle ear pressure (MEP). Forty-two ears diagnosed as normal (n = 25), with OM (n = 10), or associated with an upper respiratory infection (URI) (n = 7) were imaged with a pneumatic LCI otoscope with an axial, transverse, and temporal resolution of 6 µm, 20 µm, and 1 msec, respectively. The TM displacement under pneumatic pressure transients (a duration of 0.5 sec with an intensity of ± 150 daPa) was measured to compute two metrics (compliance and amplitude ratio). These metrics were correlated with peak acoustic admittance and MEP from tympanometry and statistically compared via Welch's t- test. As a result, the compliance represents pneumatic TM mobility, and the amplitude ratio estimates MEP. The presence of a middle ear effusion (MEE) significantly decreased compliance (p<0.001). The amplitude ratio of the OM group was statistically less than that of the normal group (p<0.01), indicating positive MEP. Unlike tympanometry, pneumatic LCI otoscopy quantifies TM mobility as well as MEP regardless of MEE presence. With combined benefits of pneumatic otoscopy and tympanometry, pneumatic LCI otoscopy may provide new quantitative metrics for understanding TM dynamics and diagnosing OM.

  9. Pneumatic low-coherence interferometry otoscope to quantify tympanic membrane mobility and middle ear pressure

    PubMed Central

    Won, Jungeun; Monroy, Guillermo L.; Huang, Pin-Chieh; Dsouza, Roshan; Hill, Malcolm C.; Novak, Michael A.; Porter, Ryan G.; Chaney, Eric; Barkalifa, Ronit; Boppart, Stephen A.

    2018-01-01

    Pneumatic otoscopy to assess the mobility of the tympanic membrane (TM) is a highly recommended diagnostic method of otitis media (OM), a widespread middle ear infection characterized by the fluid accumulation in the middle ear. Nonetheless, limited depth perception and subjective interpretation of small TM displacements have challenged the appropriate and efficient examination of TM dynamics experienced during OM. In this paper, a pneumatic otoscope integrated with low coherence interferometry (LCI) was adapted with a controlled pressure-generating system to record the pneumatic response of the TM and to estimate middle ear pressure (MEP). Forty-two ears diagnosed as normal (n = 25), with OM (n = 10), or associated with an upper respiratory infection (URI) (n = 7) were imaged with a pneumatic LCI otoscope with an axial, transverse, and temporal resolution of 6 µm, 20 µm, and 1 msec, respectively. The TM displacement under pneumatic pressure transients (a duration of 0.5 sec with an intensity of ± 150 daPa) was measured to compute two metrics (compliance and amplitude ratio). These metrics were correlated with peak acoustic admittance and MEP from tympanometry and statistically compared via Welch’s t-test. As a result, the compliance represents pneumatic TM mobility, and the amplitude ratio estimates MEP. The presence of a middle ear effusion (MEE) significantly decreased compliance (p<0.001). The amplitude ratio of the OM group was statistically less than that of the normal group (p<0.01), indicating positive MEP. Unlike tympanometry, pneumatic LCI otoscopy quantifies TM mobility as well as MEP regardless of MEE presence. With combined benefits of pneumatic otoscopy and tympanometry, pneumatic LCI otoscopy may provide new quantitative metrics for understanding TM dynamics and diagnosing OM. PMID:29552381

  10. Estimation of outer-middle ear transmission using DPOAEs and fractional-order modeling of human middle ear

    NASA Astrophysics Data System (ADS)

    Naghibolhosseini, Maryam

    Our ability to hear depends primarily on sound waves traveling through the outer and middle ear toward the inner ear. Hence, the characteristics of the outer and middle ear affect sound transmission to/from the inner ear. The role of the middle and outer ear in sound transmission is particularly important for otoacoustic emissions (OAEs), which are sound signals generated in a healthy cochlea, and recorded by a sensitive microphone placed in the ear canal. OAEs are used to evaluate the health and function of the cochlea; however, they are also affected by outer and middle ear characteristics. To better assess cochlear health using OAEs, it is critical to quantify the impact of the outer and middle ear on sound transmission. The reported research introduces a noninvasive approach to estimate outer-middle ear transmission using distortion product otoacoustic emissions (DPOAEs). In addition, the role of the outer and middle ear on sound transmission was investigated by developing a physical/mathematical model, which employed fractional-order lumped elements to include the viscoelastic characteristics of biological tissues. Impedance estimations from wideband refectance measurements were used for parameter fitting of the model. The model was validated comparing its estimates of the outer-middle ear sound transmission with those given by DPOAEs. The outer-middle ear transmission by the model was defined as the sum of forward and reverse outer-middle ear transmissions. To estimate the reverse transmission by the model, the probe-microphone impedance was calculated through estimating the Thevenin-equivalent circuit of the probe-microphone. The Thevenin-equivalent circuit was calculated using measurements in a number of test cavities. Such modeling enhances our understanding of the roles of different parts of the outer and middle ear and how they work together to determine their function. In addition, the model would be potentially helpful in diagnosing pathologies of cochlear or middle ear origin.

  11. EARS: An Online Bibliographic Search and Retrieval System Based on Ordered Explosion.

    ERIC Educational Resources Information Center

    Ramesh, R.; Drury, Colin G.

    1987-01-01

    Provides overview of Ergonomics Abstracts Retrieval System (EARS), an online bibliographic search and retrieval system in the area of human factors engineering. Other online systems are described, the design of EARS based on inverted file organization is explained, and system expansions including a thesaurus are discussed. (Author/LRW)

  12. Naturalistic observation of health-relevant social processes: the electronically activated recorder methodology in psychosomatics.

    PubMed

    Mehl, Matthias R; Robbins, Megan L; Deters, Fenne Große

    2012-05-01

    This article introduces a novel observational ambulatory monitoring method called the electronically activated recorder (EAR). The EAR is a digital audio recorder that runs on a handheld computer and periodically and unobtrusively records snippets of ambient sounds from participants' momentary environments. In tracking moment-to-moment ambient sounds, it yields acoustic logs of people's days as they naturally unfold. In sampling only a fraction of the time, it protects participants' privacy and makes large observational studies feasible. As a naturalistic observation method, it provides an observer's account of daily life and is optimized for the objective assessment of audible aspects of social environments, behaviors, and interactions (e.g., habitual preferences for social settings, idiosyncratic interaction styles, subtle emotional expressions). This article discusses the EAR method conceptually and methodologically, reviews prior research with it, and identifies three concrete ways in which it can enrich psychosomatic research. Specifically, it can (a) calibrate psychosocial effects on health against frequencies of real-world behavior; (b) provide ecological observational measures of health-related social processes that are independent of self-report; and (c) help with the assessment of subtle and habitual social behaviors that evade self-report but have important health implications. An important avenue for future research lies in merging traditional self-report-based ambulatory monitoring methods with observational approaches such as the EAR to allow for the simultaneous yet methodologically independent assessment of inner, experiential aspects (e.g., loneliness) and outer, observable aspects (e.g., social isolation) of real-world social processes to reveal their unique effects on health.

  13. Group Playing by Ear in Higher Education: The Processes That Support Imitation, Invention and Group Improvisation

    ERIC Educational Resources Information Center

    Varvarigou, Maria

    2017-01-01

    This article explores how group playing by ear (GEP) through imitation of recorded material and opportunities for inventive work during peer interaction was used to support first year undergraduate western classical music students' aural, group creativity and improvisation skills. The framework that emerged from the analysis of the data describes…

  14. 49 CFR 391.43 - Medical examination; certificate of physical examination.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., congestive heart failure, or cardiovascular disease that is accompanied by syncope, dyspnea, or collapse... ear disease, symptoms of aural vertigo, or Meniere's Syndrome. When recording hearing, record distance...

  15. What the Toadfish Ear Tells the Toadfish Brain About Sound.

    PubMed

    Edds-Walton, Peggy L

    2016-01-01

    Of the three, paired otolithic endorgans in the ear of teleost fishes, the saccule is the one most often demonstrated to have a major role in encoding frequencies of biologically relevant sounds. The toadfish saccule also encodes sound level and sound source direction in the phase-locked activity conveyed via auditory afferents to nuclei of the ipsilateral octaval column in the medulla. Although paired auditory receptors are present in teleost fishes, binaural processes were believed to be unimportant due to the speed of sound in water and the acoustic transparency of the tissues in water. In contrast, there are behavioral and anatomical data that support binaural processing in fishes. Studies in the toadfish combined anatomical tract-tracing and physiological recordings from identified sites along the ascending auditory pathway to document response characteristics at each level. Binaural computations in the medulla and midbrain sharpen the directional information provided by the saccule. Furthermore, physiological studies in the central nervous system indicated that encoding frequency, sound level, temporal pattern, and sound source direction are important components of what the toadfish ear tells the toadfish brain about sound.

  16. The tympanic membrane displacement test and tinnitus: preliminary report on clinical observations, applications, and implications.

    PubMed

    Shulman, Abraham; Goldstein, Barbara; Marchbanks, Robert J

    2012-01-01

    The tympanic membrane displacement test (TMDT) is an attempt to record intracranial pressure (ICP) reflective of an intracranial pulse pressure amplitude wave (IPPA) transmitted to the inner ear and tympanic membrane with a probe placed into the external ear canal. Twelve tinnitus patients, divided into two groups, who were resistant to attempts to achieve tinnitus control or relief were selected for the TMDT. The group 1 TMDT recordings were obtained on one session test date, and group 2 (n = 6) recordings were obtained sequentially on different session test dates. Patient selection with the medical audiologic tinnitus patient protocol (MATPP) identified all to have a nonpulsatile, predominantly central-type severe disabling subjective idiopathic tinnitus (SIT) resistant to attempts for tinnitus relief with instrumentation or medication. Associated complaints in all selected SIT patients included persistent ear blockage in the SIT ear, normal middle-ear function, controlled secondary endolymphatic hydrops in the SIT ear, sensorineural hearing loss of high frequency, hyperacusis, occasional vertigo, and central nervous system complaints of headache, head pressure, and cognitive interference in memory and/or speech expression. Clinical concern is for the presence of an increased ICP reflecting an idiopathic intracranial hypertension (IIH) which, if not identified and treated, may be a factor influencing the clinical course of this particular cohort of SIT patients, highlighted by persistent ear blockage and associated complaints as described. We set out to accomplish a number of goals: (1) To identify abnormal intracranial pulse pressure (IPPA ICP) with the extracranial TMD in a preselected particular cohort of SIT patients clinically suspected (by use of the MATPP) to have an abnormal ICP (i.e., IIH); (2) to identify the abnormal IPPA ICP as a positive indicator for IIH and as a factor - not an etiology - influencing the clinical course of SIT in a preselected cohort of SIT patients; (3) to identify with the TMDT in SIT patients spontaneous nonevoked recordings of intra-aural pressure and test-retest reliability of the TMDT; (4) to identify with the TMDT levels of normal and abnormal IPPA ICP in real time in the clinical course of SIT (i.e., an objective diagnostic and treatment monitor function of the TMD targeting ICP and IIH before and after treatment); (5) to attempt to establish a correlation of treatment efficacy, targeting preand post-ICP as a manifestation of IIH, with SIT subjective tinnitus relief; (6) to identify the limitations and complications of the TMDT; and (7) to share with the reader the evolution of a new science of brain pulsatility and a technology having a clinical application for otology and neurotology complaints of hearing loss, tinnitus, ear blockage, and vertigo. The results reported in the literature complement and alter conventional medical teaching focusing on brain pulsation, absolute intracranial pressure, and brain disease. The Southampton Tympanic Membrane Displacement Analyzer was used to record spontaneous intra-aural pressure waves in 12 SIT patients. Patients selected for the TMDT were divided into two groups: Group 1 (n = 6) recordings were obtained on one session test date, and group 2 (n = 6) recordings were obtained sequentially on different session test dates. Multiple recordings were attempted in all patients to identify test-retest reliability in both groups. An attempt for treatment and control of an elevated ICP with or without reduced cerebral compliance (CC) was recommended in 4 patients. With single and multiple recordings using the TMDT, the IPPA (i.e., ICP) was demonstrated to be abnormal and to fluctuate in the clinical course of 10 of the 12 predominantly central-type tinnitus patients (SIT): abnormal IIPA with reduced CC in 8 of 12 patients and normal IPPA with reduced compliance in 2 of 12. Tinnitus treatment results targeting ICP as a manifestation of IIH with Diamox were positive in the short term in 2 patients and incomplete in 3. The SIT relief is reflective of fluctuation in the ICP and the overall issue of multifactorial brain pulsatility. (1) The TMDT demonstrated repeated and consistent spontaneous nonevoked recordings of displacement of the tympanic membrane, reflective of intra-aural pressure, abnormal IPPA ICP in a preselected particular cohort of SIT patients clinically suspected to have an abnormal ICP (i.e., IIH). (2) Test-retest reliability of the TMDT was positive. (3) The results of the TMDT application for identification of an elevated ICP and reduced CC were positive in 10 of 12 particular preselected patients with nonpulsatile, predominantly central-type SIT resistant to attempts for tinnitus relief with instrumentation or medication. These positive findings support clinical and basic science investigations previously reported in the literature. (4) The clinical significance of these preliminary results of an elevated ICP in a particular cohort of SIT patients supports the clinical impression of the presence of an IIH and its influence on the clinical course and overall treatment of SIT. (5) A final conclusion as to the clinical significance of an elevated ICP and reduced CC for IIH and the diagnosis and treatment of tinnitus remains to be established.

  17. In vivo imaging of middle-ear and inner-ear microstructures of a mouse guided by SD-OCT combined with a surgical microscope

    PubMed Central

    Cho, Nam Hyun; Jang, Jeong Hun; Jung, Woonggyu; Kim, Jeehyun

    2014-01-01

    We developed an augmented-reality system that combines optical coherence tomography (OCT) with a surgical microscope. By sharing the common optical path in the microscope and OCT, we could simultaneously acquire OCT and microscope views. The system was tested to identify the middle-ear and inner-ear microstructures of a mouse. Considering the probability of clinical application including otorhinolaryngology, diseases such as middle-ear effusion were visualized using in vivo mouse and OCT images simultaneously acquired through the eyepiece of the surgical microscope during surgical manipulation using the proposed system. This system is expected to realize a new practical area of OCT application. PMID:24787787

  18. Binaural electric-acoustic interactions recorded from the inferior colliculus of Guinea pigs: the effect of masking observed in the central nucleus of the inferior colliculus.

    PubMed

    Noh, Heil; Lee, Dong-Hee

    2012-09-01

    To investigate the electric-acoustic interactions within the inferior colliculus of guinea pigs and to observe how central masking appears in invasive neural recordings of the inferior colliculus (IC). A platinum-iridium wire was inserted to scala tympani through cochleostomy with a depth no greater than 1 mm for intracochlear stimulation of electric pulse train. A 5 mm 100 µm, single-shank, thin-film, penetrating recording probe was inserted perpendicularly to the surface of the IC in the coronal plane at an angle of 30-40° off the parasagittal plane with a depth of 2.0-2.5 mm. The peripheral and central masking effects were compared using electric pulse trains to the left ear and acoustic noise to the left ear (ipsilateral) and to the right ear (contralateral). Binaural acoustic stimuli were presented with different time delays and compared with combined electric and acoustic stimuli. The averaged evoked potentials and total spike numbers were measured using thin-film electrodes inserted into the central nucleus of the IC. Ipsilateral noise had more obvious effects on the electric response than did contralateral noise. Contralateral noise decreased slightly the response amplitude to the electric pulse train stimuli. Immediately after the onset of acoustic noise, the response pattern changed transiently with shorter response intervals. The effects of contralateral noise were evident at the beginning of the continuous noise. The total spike number decreased when the binaural stimuli reached the IC most simultaneously. These results suggest that central masking is quite different from peripheral masking and occurs within the binaural auditory system, and this study showed that the effect of masking could be observed in the IC recording. These effects are more evident and consistent with the psychophysical data from spike number analyses than with the previously reported gross potential data.

  19. In vivo and in vitro biophysical properties of hair cells from the lateral line and inner ear of developing and adult zebrafish.

    PubMed

    Olt, Jennifer; Johnson, Stuart L; Marcotti, Walter

    2014-05-15

    Hair cells detect and process sound and movement information, and transmit this with remarkable precision and efficiency to afferent neurons via specialized ribbon synapses. The zebrafish is emerging as a powerful model for genetic analysis of hair cell development and function both in vitro and in vivo. However, the full exploitation of the zebrafish is currently limited by the difficulty in obtaining systematic electrophysiological recordings from hair cells under physiological recording conditions. Thus, the biophysical properties of developing and adult zebrafish hair cells are largely unknown. We investigated potassium and calcium currents, voltage responses and synaptic activity in hair cells from the lateral line and inner ear in vivo and using near-physiological in vitro recordings. We found that the basolateral current profile of hair cells from the lateral line becomes more segregated with age, and that cells positioned in the centre of the neuromast show more mature characteristics and those towards the edge retain a more immature phenotype. The proportion of mature-like hair cells within a given neuromast increased with zebrafish development. Hair cells from the inner ear showed a developmental change in current profile between the juvenile and adult stages. In lateral line hair cells from juvenile zebrafish, exocytosis also became more efficient and required less calcium for vesicle fusion. In hair cells from mature zebrafish, the biophysical characteristics of ion channels and exocytosis resembled those of hair cells from other lower vertebrates and, to some extent, those in the immature mammalian vestibular and auditory systems. We show that although the zebrafish provides a suitable animal model for studies on hair cell physiology, it is advisable to consider that the age at which the majority of hair cells acquire a mature-type configuration is reached only in the juvenile lateral line and in the inner ear from >2 months after hatching. © 2014 The Authors. The Journal of Physiology published by John Wiley & Sons Ltd on behalf of The Physiological Society.

  20. Unobtrusive Biometric System Based on Electroencephalogram Analysis

    NASA Astrophysics Data System (ADS)

    Riera, A.; Soria-Frisch, A.; Caparrini, M.; Grau, C.; Ruffini, G.

    2007-12-01

    Features extracted from electroencephalogram (EEG) recordings have proved to be unique enough between subjects for biometric applications. We show here that biometry based on these recordings offers a novel way to robustly authenticate or identify subjects. In this paper, we present a rapid and unobtrusive authentication method that only uses 2 frontal electrodes referenced to another one placed at the ear lobe. Moreover, the system makes use of a multistage fusion architecture, which demonstrates to improve the system performance. The performance analysis of the system presented in this paper stems from an experiment with 51 subjects and 36 intruders, where an equal error rate (EER) of 3.4% is obtained, that is, true acceptance rate (TAR) of 96.6% and a false acceptance rate (FAR) of 3.4%. The obtained performance measures improve the results of similar systems presented in earlier work.

  1. Single-channel in-ear-EEG detects the focus of auditory attention to concurrent tone streams and mixed speech.

    PubMed

    Fiedler, Lorenz; Wöstmann, Malte; Graversen, Carina; Brandmeyer, Alex; Lunner, Thomas; Obleser, Jonas

    2017-06-01

    Conventional, multi-channel scalp electroencephalography (EEG) allows the identification of the attended speaker in concurrent-listening ('cocktail party') scenarios. This implies that EEG might provide valuable information to complement hearing aids with some form of EEG and to install a level of neuro-feedback. To investigate whether a listener's attentional focus can be detected from single-channel hearing-aid-compatible EEG configurations, we recorded EEG from three electrodes inside the ear canal ('in-Ear-EEG') and additionally from 64 electrodes on the scalp. In two different, concurrent listening tasks, participants (n  =  7) were fitted with individualized in-Ear-EEG pieces and were either asked to attend to one of two dichotically-presented, concurrent tone streams or to one of two diotically-presented, concurrent audiobooks. A forward encoding model was trained to predict the EEG response at single EEG channels. Each individual participants' attentional focus could be detected from single-channel EEG response recorded from short-distance configurations consisting only of a single in-Ear-EEG electrode and an adjacent scalp-EEG electrode. The differences in neural responses to attended and ignored stimuli were consistent in morphology (i.e. polarity and latency of components) across subjects. In sum, our findings show that the EEG response from a single-channel, hearing-aid-compatible configuration provides valuable information to identify a listener's focus of attention.

  2. Concealed, Unobtrusive Ear-Centered EEG Acquisition: cEEGrids for Transparent EEG

    PubMed Central

    Bleichner, Martin G.; Debener, Stefan

    2017-01-01

    Electroencephalography (EEG) is an important clinical tool and frequently used to study the brain-behavior relationship in humans noninvasively. Traditionally, EEG signals are recorded by positioning electrodes on the scalp and keeping them in place with glue, rubber bands, or elastic caps. This setup provides good coverage of the head, but is impractical for EEG acquisition in natural daily-life situations. Here, we propose the transparent EEG concept. Transparent EEG aims for motion tolerant, highly portable, unobtrusive, and near invisible data acquisition with minimum disturbance of a user's daily activities. In recent years several ear-centered EEG solutions that are compatible with the transparent EEG concept have been presented. We discuss work showing that miniature electrodes placed in and around the human ear are a feasible solution, as they are sensitive enough to pick up electrical signals stemming from various brain and non-brain sources. We also describe the cEEGrid flex-printed sensor array, which enables unobtrusive multi-channel EEG acquisition from around the ear. In a number of validation studies we found that the cEEGrid enables the recording of meaningful continuous EEG, event-related potentials and neural oscillations. Here, we explain the rationale underlying the cEEGrid ear-EEG solution, present possible use cases and identify open issues that need to be solved on the way toward transparent EEG. PMID:28439233

  3. Comparison of tympanic and rectal temperature in febrile patients.

    PubMed

    Sehgal, Arvind; Dubey, N K; Jyothi, M C; Jain, Shilpa

    2002-04-01

    To compare tympanic membrane temperature and rectal temperature in febrile pediatric patients. Sixty febrile children were enrolled as continuous enrollment at initial triage. Two readings of ear temperature were taken in each child with Thermoscan infrared thermometer. Rectal temperature was recorded by a digital electronic thermometer. Comparison of both the techniques was done and co-relation co-efficients calculated. Parental preference for both techniques was assessed. It was observed that mean ear temperature was 38.9+/-0.90 C and that for rectal temperature was 38.8+/-0.80 degrees C. The correlation coefficient between the two was 0.994 (p < 0.01). Coefficients for both sites were comparable over a wide age range. The difference between readings taken from two ears was not significant. Temperature ranges over which readings were recorded were quite wide for both techniques. Parental preference for tympanic thermometry over rectal thermometry was noticed. Tympanic thermometry utilizes pyro-electric sensors, to detect infra-red rays emitted from the surface of tympanic membrane. Ear temperatures correlates well with rectal temperatures which have long been considered as "core" temperatures. Parents prefer the technique of ear thermometry which is quick (2 sec), safe and non-invasive and patient resistance for this is also less. A non-invasive, non-mucous device which is accurate over a wide range of temperature could be very useful.

  4. Big Stimulus, Little Ears: Safety in Administering Vestibular Evoked Myogenic Potentials (VEMP) in Children

    PubMed Central

    Thomas, Megan L.A.; Fitzpatrick, Denis; McCreery, Ryan; Janky, Kristen L.

    2017-01-01

    Background Cervical and ocular Vestibular Evoked Myogenic Potentials (VEMPs) have become common clinical vestibular assessments. However, VEMP testing requires high intensity stimuli, raising concerns regarding safety with children, where sound pressure levels may be higher due to their smaller ear canal volumes. Purpose The purpose of this study was to estimate the range of peak-to-peak equivalent sound pressure levels (peSPLs) in child and adult ears in response to high intensity stimuli (i.e., 100 dB normal hearing level (nHL)) commonly used for VEMP testing and make a determination of whether acoustic stimuli levels with VEMP testing are safe for use in children. Research Design Prospective Experimental. Study Sample Ten children (4–6 years) and ten young adults (24 – 35 years) with normal hearing sensitivity and middle ear function participated in the study. Data Collection and Analysis Probe microphone peSPL measurements of clicks and 500 Hz tonebursts (TBs) were recorded in tubes of small, medium, and large diameter, and in a Brüel & Kjær Ear Simulator Type 4157 to assess for linearity of the stimulus at high levels. The different diameter tubes were used to approximate the range of cross-sectional areas in infant, child, and adult ears, respectively. Equivalent ear canal volume and peSPL measurements were then recorded in child and adult ears. Lower intensity levels were used in the participant’s ears to limit exposure to high intensity sound. The peSPL measurements in participant ears were extrapolated using predictions from linear mixed models to determine if equivalent ear canal volume significantly contributed to overall peSPL and to estimate the mean and 95% confidence intervals of peSPLs in child and adult ears when high intensity stimulus levels (100 dB nHL) are used for VEMP testing without exposing subjects to high-intensity stimuli. Results Measurements from the coupler and tubes suggested: 1) each stimuli was linear, 2) there were no distortions or non-linearities at high levels, and 3) peSPL increased with decreased tube diameter. Measurements in participant ears suggested: 1) peSPL was approximately 3 dB larger in child compared to adult ears, and 2) peSPL was larger in response to clicks compared to 500 Hz TBs. The model predicted the following 95% confidence interval for a 100 dB nHL click: 127–136.5 dB peSPL in adult ears and 128.7–138.2 dB peSPL in child ears. The model predicted the following 95% confidence interval for a 100 dB nHL 500 Hz TB stimulus: 122.2 – 128.2 dB peSPL in adult ears and 124.8–130.8 dB peSPL in child ears. Conclusions Our findings suggest that 1) when completing VEMP testing, the stimulus is approximately 3 dB higher in a child’s ear, 2) a 500 Hz TB is recommended over a click as it has lower peSPL compared to the click, and 3) both duration and intensity should be considered when choosing VEMP stimuli. Calculating the total sound energy exposure for your chosen stimuli is recommended as it accounts for both duration and intensity. When using this calculation for children, consider adding 3 dB to the stimulus level. PMID:28534730

  5. Big Stimulus, Little Ears: Safety in Administering Vestibular-Evoked Myogenic Potentials in Children.

    PubMed

    Thomas, Megan L A; Fitzpatrick, Denis; McCreery, Ryan; Janky, Kristen L

    2017-05-01

    Cervical and ocular vestibular-evoked myogenic potentials (VEMPs) have become common clinical vestibular assessments. However, VEMP testing requires high intensity stimuli, raising concerns regarding safety with children, where sound pressure levels may be higher due to their smaller ear canal volumes. The purpose of this study was to estimate the range of peak-to-peak equivalent sound pressure levels (peSPLs) in child and adult ears in response to high intensity stimuli (i.e., 100 dB normal hearing level [nHL]) commonly used for VEMP testing and make a determination of whether acoustic stimuli levels with VEMP testing are safe for use in children. Prospective experimental. Ten children (4-6 years) and ten young adults (24-35 years) with normal hearing sensitivity and middle ear function participated in the study. Probe microphone peSPL measurements of clicks and 500 Hz tonebursts (TBs) were recorded in tubes of small, medium, and large diameter, and in a Brüel & Kjær Ear Simulator Type 4157 to assess for linearity of the stimulus at high levels. The different diameter tubes were used to approximate the range of cross-sectional areas in infant, child, and adult ears, respectively. Equivalent ear canal volume and peSPL measurements were then recorded in child and adult ears. Lower intensity levels were used in the participant's ears to limit exposure to high intensity sound. The peSPL measurements in participant ears were extrapolated using predictions from linear mixed models to determine if equivalent ear canal volume significantly contributed to overall peSPL and to estimate the mean and 95% confidence intervals of peSPLs in child and adult ears when high intensity stimulus levels (100 dB nHL) are used for VEMP testing without exposing subjects to high-intensity stimuli. Measurements from the coupler and tubes suggested: 1) each stimuli was linear, 2) there were no distortions or nonlinearities at high levels, and 3) peSPL increased with decreased tube diameter. Measurements in participant ears suggested: 1) peSPL was approximately 3 dB larger in child compared to adult ears, and 2) peSPL was larger in response to clicks compared to 500 Hz TBs. The model predicted the following 95% confidence interval for a 100 dB nHL click: 127-136.5 dB peSPL in adult ears and 128.7-138.2 dB peSPL in child ears. The model predicted the following 95% confidence interval for a 100 dB nHL 500 Hz TB stimulus: 122.2-128.2 dB peSPL in adult ears and 124.8-130.8 dB peSPL in child ears. Our findings suggest that 1) when completing VEMP testing, the stimulus is approximately 3 dB higher in a child's ear, 2) a 500 Hz TB is recommended over a click as it has lower peSPL compared to the click, and 3) both duration and intensity should be considered when choosing VEMP stimuli. Calculating the total sound energy exposure for your chosen stimuli is recommended as it accounts for both duration and intensity. When using this calculation for children, consider adding 3 dB to the stimulus level. American Academy of Audiology

  6. Speech auditory brainstem response (speech ABR) characteristics depending on recording conditions, and hearing status: an experimental parametric study.

    PubMed

    Akhoun, Idrick; Moulin, Annie; Jeanvoine, Arnaud; Ménard, Mikael; Buret, François; Vollaire, Christian; Scorretti, Riccardo; Veuillet, Evelyne; Berger-Vachon, Christian; Collet, Lionel; Thai-Van, Hung

    2008-11-15

    Speech elicited auditory brainstem responses (Speech ABR) have been shown to be an objective measurement of speech processing in the brainstem. Given the simultaneous stimulation and recording, and the similarities between the recording and the speech stimulus envelope, there is a great risk of artefactual recordings. This study sought to systematically investigate the source of artefactual contamination in Speech ABR response. In a first part, we measured the sound level thresholds over which artefactual responses were obtained, for different types of transducers and experimental setup parameters. A watermelon model was used to model the human head susceptibility to electromagnetic artefact. It was found that impedances between the electrodes had a great effect on electromagnetic susceptibility and that the most prominent artefact is due to the transducer's electromagnetic leakage. The only artefact-free condition was obtained with insert-earphones shielded in a Faraday cage linked to common ground. In a second part of the study, using the previously defined artefact-free condition, we recorded speech ABR in unilateral deaf subjects and bilateral normal hearing subjects. In an additional control condition, Speech ABR was recorded with the insert-earphones used to deliver the stimulation, unplugged from the ears, so that the subjects did not perceive the stimulus. No responses were obtained from the deaf ear of unilaterally hearing impaired subjects, nor in the insert-out-of-the-ear condition in all the subjects, showing that Speech ABR reflects the functioning of the auditory pathways.

  7. Fitting and verification of frequency modulation systems on children with normal hearing.

    PubMed

    Schafer, Erin C; Bryant, Danielle; Sanders, Katie; Baldus, Nicole; Algier, Katherine; Lewis, Audrey; Traber, Jordan; Layden, Paige; Amin, Aneeqa

    2014-06-01

    Several recent investigations support the use of frequency modulation (FM) systems in children with normal hearing and auditory processing or listening disorders such as those diagnosed with auditory processing disorders, autism spectrum disorders, attention-deficit hyperactivity disorder, Friedreich ataxia, and dyslexia. The American Academy of Audiology (AAA) published suggested procedures, but these guidelines do not cite research evidence to support the validity of the recommended procedures for fitting and verifying nonoccluding open-ear FM systems on children with normal hearing. Documenting the validity of these fitting procedures is critical to maximize the potential FM-system benefit in the above-mentioned populations of children with normal hearing and those with auditory-listening problems. The primary goal of this investigation was to determine the validity of the AAA real-ear approach to fitting FM systems on children with normal hearing. The secondary goal of this study was to examine speech-recognition performance in noise and loudness ratings without and with FM systems in children with normal hearing sensitivity. A two-group, cross-sectional design was used in the present study. Twenty-six typically functioning children, ages 5-12 yr, with normal hearing sensitivity participated in the study. Participants used a nonoccluding open-ear FM receiver during laboratory-based testing. Participants completed three laboratory tests: (1) real-ear measures, (2) speech recognition performance in noise, and (3) loudness ratings. Four real-ear measures were conducted to (1) verify that measured output met prescribed-gain targets across the 1000-4000 Hz frequency range for speech stimuli, (2) confirm that the FM-receiver volume did not exceed predicted uncomfortable loudness levels, and (3 and 4) measure changes to the real-ear unaided response when placing the FM receiver in the child's ear. After completion of the fitting, speech recognition in noise at a -5 signal-to-noise ratio and loudness ratings at a +5 signal-to-noise ratio were measured in four conditions: (1) no FM system, (2) FM receiver on the right ear, (3) FM receiver on the left ear, and (4) bilateral FM system. The results of this study suggested that the slightly modified AAA real-ear measurement procedures resulted in a valid fitting of one FM system on children with normal hearing. On average, prescriptive targets were met for 1000, 2000, 3000, and 4000 Hz within 3 dB, and maximum output of the FM system never exceeded and was significantly lower than predicted uncomfortable loudness levels for the children. There was a minimal change in the real-ear unaided response when the open-ear FM receiver was placed into the ear. Use of the FM system on one or both ears resulted in significantly better speech recognition in noise relative to a no-FM condition, and the unilateral and bilateral FM receivers resulted in a comfortably loud signal when listening in background noise. Real-ear measures are critical for obtaining an appropriate fit of an FM system on children with normal hearing. American Academy of Audiology.

  8. Prevalence of ear disease in dogs undergoing multidetector thin-slice computed tomography of the head.

    PubMed

    Foster, Allison; Morandi, Federica; May, Elizabeth

    2015-01-01

    Previous reports describing the prevalence of ear diseases in dogs have primarily been based on dogs presenting with clinical signs of disease. The prevalence of subclinical ear disease remains unknown. The purpose of this cross-sectional retrospective study was to describe the prevalence of lesions consistent with middle and external ear disease in dogs presented for multidetector computed tomography (CT) of the head and/or cranial cervical spine at our hospital during the period of July 2011 and August 2013. For each included dog, data recorded were signalment, CT findings, diagnosis, and treatment. A total of 199 dogs met inclusion criteria. Nineteen dogs (9.5%) were referred for evaluation of suspected ear disease and 27 dogs (13.5%) had histories or physical examination findings consistent with otitis externa. A total of 163 dogs (81.9%) had CT lesions consistent with external ear disease (i.e. ear canal mineralization, external canal thickening, and/or narrowing of the external canal). Thirty-nine dogs (19.5%) had CT lesions consistent with middle ear disease (i.e. soft tissue attenuating/fluid material in the tympanic bullae, bulla wall thickening or lysis, and/or periosteal proliferation of the temporal bone). Findings from this study indicated that the prevalence of external and middle ear disease in dogs could be higher than that previously reported. © 2014 American College of Veterinary Radiology.

  9. Aetiological agents of ear discharge: a two year review in a teaching hospital in Ghana.

    PubMed

    Appiah-Korang, L; Asare-Gyasi, S; Yawson, A E; Searyoh, K

    2014-06-01

    The discharging ear is a common presentation in medical practice affecting all age groups but primarily children. This study shows the current aetiological causes of ear discharge and their antibiograms, data which would guide empirical treatment of ear infections, and also form a basis for further research. This was a retrospective review of laboratory records of all ear swabs submitted for culture over a two year period in the Korle Bu Teaching Hospital Accra, Ghana. Data was obtained on demographic characteristics of patients, clinical diagnosis, isolated organisms and antibiotic susceptibility patterns of the isolated organisms. Data was analyzed by simple descriptive statistics. A total of 351 ear swabs were received by the laboratory for processing over the two year period. Of these 277(78.9%) had microorganisms isolated. A significant number127 (47%) was obtained from children under five years. Pseudomonas spp was the commonly isolated organism 121(46%) followed by Staphylococcus aureus 33(12.5%) and Proteus spp 32(12.2%). Candida was the commonest isolated fungi 9 (69.2%). Susceptibility of Pseudomonas spp to commonly used ototopics (ciprofloxacin & gentamicin) was 93% and 74% respectively. Most cases of the discharging ear were found in children under the age of five years. The most common bacteriologic cause of the discharging ear was Pseudomonas spp followed by Staphylococcus aureus. Candida species was the commonest fungal cause of ear discharge. Ciprofloxacin and gentamicin are effective ototopic antimicrobial agents for empirical treatment of the discharging ear.

  10. Effects of active noise reduction on noise levels at the tympanic membrane.

    PubMed

    Wagstaff, A S; Woxen, O J; Andersen, H T

    1998-06-01

    Active noise reduction (ANR) is an electronic system that works by continuous sampling of noise inside the earshell of the headset with a small microphone. This signal is inverted in phase through the headset speaker, thus reducing noise levels by destructive interference of the acoustic field. The system provides good low-frequency noise attenuation, but aircrew differ in their subjective opinion of ANR. The present study is an attempt to provide an objective assessment of the effect of ANR on noise levels at the tympanic membrane. There were 7 subjects with normal ears who were placed in an environment of recorded noise from a BO-105 helicopter. A microphone probe was inserted to within 5 mm of the tympanic membrane of each subject's right ear. Noise levels in the ear were measured without a headset and with two different ANR headsets. Measurements were performed with and without the ANR system on, and with and without white noise through the headset communication system. The white noise was used to simulate aircraft communication noise. The two headsets tested had differing levels of passive and active attenuation. The ANR system produced a substantial low-frequency attenuation. However, noise levels in the mid frequencies increased somewhat when the ANR system was switched on. This effect was augmented when white noise in the communications system was introduced, particularly for one of the two headsets. Low-frequency noise attenuation of ANR systems is substantial, but an increased mid- and high-frequency noise level caused by the ANR may affect both communication and overall noise levels. Our data provide advice on what factors should be taken into account when ANR is evaluated for use in an aviation operational environment.

  11. Effect of Probe Tube Insertion Depth on Spectral Measures of Speech

    PubMed Central

    Caldwell, Marc; Souza, Pamela E.; Tremblay, Kelly L.

    2006-01-01

    This study investigated how depth variations in the tip of the probe tube affected spectral measures of speech recorded in the external ear canal. Consonant-vowel nonsense syllables were recorded with a probe tube microphone system in 10 adult participants with normal middle ear function. Recordings were made with the probe tube tip placed 1 mm, 5 mm, and 10 mm beyond the medial tip of a custom earmold. The effect of probe depth was evaluated on spectral levels (one-third octave and one-twelfth octave band). Extending the probe tube 10 mm past the medial tip of the earmold gave the most accurate results, with relatively lower sound levels for either the 1-mm or 5-mm insertion depth. In general, the effect of insertion depth was minimal at frequencies below 3 to 4 kHz, although this varied with the specific phoneme and the width of the analysis bands. The authors found no significant difference between 1- and 5-mm insertion depths, suggesting that as long as the tip of the probe tube is sufficiently close to the tympanic membrane to capture the highest frequency of interest, it makes little difference if it is less than 5 mm beyond the earmold tip. PMID:16959735

  12. Tympanal mechanics and neural responses in the ears of a noctuid moth

    NASA Astrophysics Data System (ADS)

    Ter Hofstede, Hannah M.; Goerlitz, Holger R.; Montealegre-Z, Fernando; Robert, Daniel; Holderied, Marc W.

    2011-12-01

    Ears evolved in many groups of moths to detect the echolocation calls of predatory bats. Although the neurophysiology of bat detection has been intensively studied in moths for decades, the relationship between sound-induced movement of the noctuid tympanic membrane and action potentials in the auditory sensory cells (A1 and A2) has received little attention. Using laser Doppler vibrometry, we measured the velocity and displacement of the tympanum in response to pure tone pulses for moths that were intact or prepared for neural recording. When recording from the auditory nerve, the displacement of the tympanum at the neural threshold remained constant across frequencies, whereas velocity varied with frequency. This suggests that the key biophysical parameter for triggering action potentials in the sensory cells of noctuid moths is tympanum displacement, not velocity. The validity of studies on the neurophysiology of moth hearing rests on the assumption that the dissection and recording procedures do not affect the biomechanics of the ear. There were no consistent differences in tympanal velocity or displacement when moths were intact or prepared for neural recordings for sound levels close to neural threshold, indicating that this and other neurophysiological studies provide good estimates of what intact moths hear at threshold.

  13. Continuous 24-hour measurement of middle ear pressure.

    PubMed

    Tideholm, B; Jönsson, S; Carlborg, B; Welinder, R; Grenner, J

    1996-07-01

    A new method was developed for continuous measurement of the middle ear pressure during a 24-h period. The equipment consisted of a piezo-electric pressure device and a digital memory. To allow continuous pressure recordings during normal every-day activities the equipment was made light and portable. The measurement accuracy of the equipment as well as the base-line and temperature stability were tested and found to meet to our requirements satisfactorily. In 4 volunteers with different middle ear conditions, a small perforation was made through the tympanic membrane. A rubber stopper containing a small polyethylene tube was fitted into the external ear canal. Tubal function tests were made to establish the equipment's ability to monitor fast pressure changes. The tests were well in accordance with other methods of direct pressure measurements. The equipment was carried by the volunteers for 24 h to monitor any slow or rapid dynamic pressure changes in the middle ear. Four continuous 24-h measurements are presented. The method was found to be suitable for valid measurements of dynamic pressure changes in the middle ear during normal every-day activities. It may become a useful instrument in the search for a better understanding of the development of chronic middle ear disease.

  14. PubMed Central

    Labrecque, M; Dostaler, L P; Dumont, H; Huard, G; Laflamme, L

    1993-01-01

    OBJECTIVE: To determine the interobserver reliability of tympanograms obtained with the MicroTymp, a portable tympanometer. SETTING: Family medicine teaching unit in a tertiary care hospital. PATIENTS: Thirty-three patients who presented to the ear, nose and throat clinic in August 1990 for an ear problem. INTERVENTION: Three residents in family medicine independently attempted to record with the MicroTymp one tympanogram for the 66 ears. We excluded the results for seven ears for which tympanograms could not be obtained. MAIN OUTCOME MEASURE: Using objective criteria, two family physicians and two residents in family medicine independently classified the 177 tympanograms into five categories (normal, possible effusion, possible perforation, possible tympano-ossicular dysfunction and unclassifiable). Reliability was estimated by means of the kappa (kappa) coefficient on 161 tympanograms from 59 ears for which the interpretation of the three tympanograms agreed. MAIN RESULTS: The interpretation of the three tympanograms agreed for 34 of the 59 ears (0.58) (kappa = 0.52, 95% confidence limits 0.45 and 0.59). There was no significant difference in interobserver reliability between pairs of observers or between symptomatic and asymptomatic ears. CONCLUSIONS: The interobserver reliability of the MicroTymp is moderate. The tympanograms obtained with the instrument should be interpreted in the context of the clinical findings. PMID:8431817

  15. Effects of high intensity noise on the vestibular system in rats

    PubMed Central

    Stewart, Courtney; Yu, Yue; Huang, Jun; Maklad, Adel; Tang, Xuehui; Allison, Jerome; Mustain, William; Zhou, Wu; Zhu, Hong

    2016-01-01

    Some individuals with noise-induced hearing loss (NIHL) also report balance problems. These accompanying vestibular complaints are not well understood. The present study used a rat model to examine the effects of noise exposure on the vestibular system. Rats were exposed to continuous broadband white noise (0–24kHz) at an intensity of 116dB sound pressure level (SPL) via insert ear phones in one ear for three hours under isoflurane anesthesia. Seven days after the exposure, a significant increase in ABR threshold (43.3±1.9dB) was observed in the noise-exposed ears, indicating hearing loss. Effects of noise exposure on vestibular function were assessed by three approaches. First, fluorescein-conjugated phalloidin staining was used to assess vestibular stereocilia following noise exposure. This analysis revealed substantial sensory stereocilia bundle loss in the saccular and utricular maculae as well as in the anterior and horizontal semicircular canal cristae, but not in the posterior semicircular canal cristae. Second, single unit recording of vestibular afferent activity was performed under pentobarbital anesthesia. A total of 548 afferents were recorded from 10 noise-treated rats and 12 control rats. Noise exposure produced a moderate reduction in baseline firing rates of regular otolith afferents and anterior semicircular canal afferents. Also a moderate change was noted in the gain and phase of the horizontal and anterior semicircular canal afferent’s response to sinusoidal head rotation (1 and 2Hz, 45 degrees/s peak velocity). Third, noise exposure did not result in significant changes in gain or phase of the horizontal rotational and translational vestibular-ocular reflex (VOR). These results suggest that noise exposure not only causes hearing loss, but also causes substantial damage in the peripheral vestibular system in the absence of immediate clinically measurable vestibular signs. These peripheral deficits, however, may lead to vestibular disorders over time. PMID:26970474

  16. The mechanism of auriculotherapy: a case report based on the fractal structure of meridian system.

    PubMed

    Bernardo-Filho, Mario; de Sá-Caputo, Danúbia da Cunha; Marin, Pedro J; Chang, Shyang

    2014-01-01

    Chinese meridian system of acupuncture has recently been deciphered as the fractal continuum of neurovascular bundles and its smaller branches. The corresponding acupuncture mechanism of therapeutics has been attributed to the magneto-electric inductive effects of the meridian system via chaotic wave of nerve innervations and blood flow. Hence, based on the proposed theory, the important sensory organ of the ears should be able to exert its influence on visceral organs and peripheral limbs. This investigation aims to verify if such a possible correlation exists between an external region of the ear and the muscle of biceps brachii in the French auriculotherapy. A region between the points of elbow and shoulder in the scaphoid fossa (upper arm), was chosen. Before the recording of surface electromyograms (EMGs), of the muscle of biceps brachii, two subjects were asked to carry out maximum voluntary isometric contractions (MVICs), of the arm. In addition, the same volunteers would be served as control group. Consequently, each subject was required to perform the three treatments of control, sham, and acupressure in random order. EMG signals were recorded for later analysis. Results indicate that the acupressure with finger at a specific point which bears possibly with a somatopic relation to the biceps brachii muscle can, in a man, modify the response of the EMGs associated with the corresponding muscle while the response of the acupressure of a sham point has different responses. Moreover, the MVIC parameters were higher in acupressure treatment than those of control and sham treatments for both subjects. In conclusion, the analysis of the findings permits us to speculate that the stimulation with the fingers in the scaphoid fossa of the ear presents electromyographic responses related to the biceps brachii muscle. Hence, the mechanism of French auriculotherapy could be derived from the same principle as that of the Chinese acupuncture.

  17. An overview of pharmacology and clinical aspects concerning the therapy of cochleo-vestibular syndromes by intratympanic drug delivery

    PubMed Central

    CHIRTEŞ, FELICIAN; ALBU, SILVIU

    2013-01-01

    Intratympanic drug delivery refers to drug administration in the middle ear, the main advantage being direct diffusion of substances in the inner ear through the round window membrane with subsequent high intralabiryntine drug concentration and very low systemic side effects. The article is a review of literature concerning the inner ear barrier systems, the physiology of inner ear fluids, intralabirinthine pharmacokinetics and the commonest drugs applied in the middle ear for the treatment of cochleo-vestibular syndromes. PMID:26527944

  18. An Effective 3D Ear Acquisition System

    PubMed Central

    Liu, Yahui; Lu, Guangming; Zhang, David

    2015-01-01

    The human ear is a new feature in biometrics that has several merits over the more common face, fingerprint and iris biometrics. It can be easily captured from a distance without a fully cooperative subject. Also, the ear has a relatively stable structure that does not change much with the age and facial expressions. In this paper, we present a novel method of 3D ear acquisition system by using triangulation imaging principle, and the experiment results show that this design is efficient and can be used for ear recognition. PMID:26061553

  19. An Effective 3D Ear Acquisition System.

    PubMed

    Liu, Yahui; Lu, Guangming; Zhang, David

    2015-01-01

    The human ear is a new feature in biometrics that has several merits over the more common face, fingerprint and iris biometrics. It can be easily captured from a distance without a fully cooperative subject. Also, the ear has a relatively stable structure that does not change much with the age and facial expressions. In this paper, we present a novel method of 3D ear acquisition system by using triangulation imaging principle, and the experiment results show that this design is efficient and can be used for ear recognition.

  20. A cross-sectional evaluation of the validity of a smartphone otoscopy device in screening for ear disease in Nepal.

    PubMed

    Mandavia, R; Lapa, T; Smith, M; Bhutta, M F

    2018-02-01

    Hearing loss is a neglected international health problem. The greatest burden of ear disease is in low-income countries where there is also a lack of resources. In this context, screening for otological disease may be worthwhile. Cupris© has developed an otoscopy device that offers the possibility of low-cost mass screening in remote communities. We evaluated the validity of this device in diagnosing ear disease and in determining whether referral to an ENT centre is warranted. Cross-sectional study. Outpatient clinic, Nepal. All adults and children were invited to take part over a 2-day period. The Cupris© device was used to record participants otological history and examination. Stored history and images were assessed in the United Kingdom by a Consultant-grade ENT Surgeon, who provided a diagnosis and decided whether referral to an ENT centre was warranted. After screening with the Cupris© device, participants were immediately assessed by a UK trained ENT Consultant Surgeon using a standard otoscope ("standard assessment"). A diagnosis was recorded for each participant and a decision was made as to whether referral to an ENT centre was warranted. Concordance in primary diagnosis (analysed per ear) and concordance in the decision to refer (analysed per patient). Cohen's kappa coefficient for inter-rater agreement in diagnosis. Fifty-six patients agreed to participate. In four patients, the quality of video recorded precluded a diagnosis or management plan. These patients were excluded from subsequent analysis, leaving 52 patients for analysis. The same diagnosis was reached for 99 of 104 ears when comparing the Cupris© device to standard assessment (95% concordance), with Cohen's kappa coefficient of 0.89. The decision as to whether a patient should be referred to an ENT centre for further assessment was the same for all 52 participants when comparing the Cupris© device to standard assessment. When compared to standard assessment, the Cupris© device is a valid tool for the diagnosis of ear disease and decision for onward referral. It shows considerable promise for use by trained non-medical workers, as a low-cost and portable tool to screen for ear disease in remote settings, particularly in low- and middle-income countries. © 2017 John Wiley & Sons Ltd.

  1. The role of intracochlear drug delivery devices in the management of inner ear disease.

    PubMed

    Ayoob, Andrew M; Borenstein, Jeffrey T

    2015-03-01

    Diseases of the inner ear include those of the auditory and vestibular systems, and frequently result in disabling hearing loss or vertigo. Despite a rapidly expanding pipeline of potential cochlear therapeutics, the inner ear remains a challenging organ for targeted drug delivery, and new technologies are required to deliver these therapies in a safe and efficacious manner. In addition to traditional approaches for direct inner ear drug delivery, novel microfluidics-based systems are under development, promising improved control over pharmacokinetics over longer periods of delivery, ultimately with application towards hair cell regeneration in humans. Advances in the development of intracochlear drug delivery systems are reviewed, including passive systems, active microfluidic technologies and cochlear prosthesis-mediated delivery. This article provides a description of novel delivery systems and their potential future clinical applications in treating inner ear disease. Recent progresses in microfluidics and miniaturization technologies are enabling the development of wearable and ultimately implantable drug delivery microsystems. Progress in this field is being spurred by the convergence of advances in molecular biology, microfluidic flow control systems and models for drug transport in the inner ear. These advances will herald a new generation of devices, with near-term applications in preclinical models, and ultimately with human clinical use for a range of diseases of the inner ear.

  2. Continuous long-term measurements of the middle ear pressure in subjects without a history of ear disease.

    PubMed

    Tideholm, B; Carlborg, B; Jönsson, S; Bylander-Groth, A

    1998-06-01

    A new method was used for continuous measurement of the middle ear (ME) pressure during a 24-h period. In 10 subjects without a history of ear disease a small perforation was made through the tympanic membrane. A tight rubber stopper containing a small polyethylene tube was fitted into the external ear canal. Conventional tubal function tests were performed. The equipment was then carried by the subjects for 24 h of normal activity to monitor any slow or rapid dynamic pressure change in the ME. Body position was found to be the most important factor affecting ME pressure variation, during the 24-h continuous pressure measurements. A significant pressure rise occurred in the recumbent position in all but one subject. Few rapid pressure equilibrations were seen during the recordings, indicating few tubal openings. This implies that the pressure changes in the ME seen in this study were mainly the result of gas exchange over the mucosa. The investigation might be a base for reference when investigating different kinds of pathologic conditions in the ear.

  3. Real-ear acoustical characteristics of impulse sound generated by golf drivers and the estimated risk to hearing: a cross-sectional study

    PubMed Central

    Zhao, Fei; Bardsley, Barry

    2014-01-01

    Objectives This study investigated real-ear acoustical characteristics in terms of the sound pressure levels (SPLs) and frequency responses in situ generated from golf club drivers at impact with a golf ball. The risk of hearing loss caused by hitting a basket of golf balls using various drivers was then estimated. Design Cross-sectional study. Setting The three driver clubs were chosen on the basis of reflection of the commonality and modern technology of the clubs. The participants were asked to choose the clubs in a random order and hit six two-piece range golf balls with each club. The experiment was carried out at a golf driving range in South Wales, UK. Participants 19 male amateur golfers volunteered to take part in the study, with an age range of 19–54 years. Outcome measures The frequency responses and peak SPLs in situ of the transient sound generated from the club at impact were recorded bilaterally and simultaneously using the GN Otometric Freefit wireless real-ear measurement system. A swing speed radar system was also used to investigate the relationship between noise level and swing speed. Results Different clubs generated significantly different real-ear acoustical characteristics in terms of SPL and frequency responses. However, they did not differ significantly between the ears. No significant correlation was found between the swing speed and noise intensity. On the basis of the SPLs measured in the present study, the percentage of daily noise exposure for hitting a basket of golf balls using the drivers described above was less than 2%. Conclusions The immediate danger of noise-induced hearing loss for amateur golfers is quite unlikely. However, it may be dangerous to hearing if the noise level generated by the golf clubs exceeded 116 dBA. PMID:24448845

  4. Long-Term Asymmetric Hearing Affects Cochlear Implantation Outcomes Differently in Adults with Pre- and Postlingual Hearing Loss

    PubMed Central

    Boisvert, Isabelle; McMahon, Catherine M.; Dowell, Richard C.; Lyxell, Björn

    2015-01-01

    In many countries, a single cochlear implant is offered as a treatment for a bilateral hearing loss. In cases where there is asymmetry in the amount of sound deprivation between the ears, there is a dilemma in choosing which ear should be implanted. In many clinics, the choice of ear has been guided by an assumption that the reorganisation of the auditory pathways caused by longer duration of deafness in one ear is associated with poorer implantation outcomes for that ear. This assumption, however, is mainly derived from studies of early childhood deafness. This study compared outcomes following implantation of the better or poorer ear in cases of long-term hearing asymmetries. Audiological records of 146 adults with bilateral hearing loss using a single hearing aid were reviewed. The unaided ear had 15 to 72 years of unaided severe to profound hearing loss before unilateral cochlear implantation. 98 received the implant in their long-term sound-deprived ear. A multiple regression analysis was conducted to assess the relative contribution of potential predictors to speech recognition performance after implantation. Duration of bilateral significant hearing loss and the presence of a prelingual hearing loss explained the majority of variance in speech recognition performance following cochlear implantation. For participants with postlingual hearing loss, similar outcomes were obtained by implanting either ear. With prelingual hearing loss, poorer outcomes were obtained when implanting the long-term sound-deprived ear, but the duration of the sound deprivation in the implanted ear did not reliably predict outcomes. Contrary to an apparent clinical consensus, duration of sound deprivation in one ear has limited value in predicting speech recognition outcomes of cochlear implantation in that ear. Outcomes of cochlear implantation are more closely related to the period of time for which the brain is deprived of auditory stimulation from both ears. PMID:26043227

  5. Biometric recognition using 3D ear shape.

    PubMed

    Yan, Ping; Bowyer, Kevin W

    2007-08-01

    Previous works have shown that the ear is a promising candidate for biometric identification. However, in prior work, the preprocessing of ear images has had manual steps and algorithms have not necessarily handled problems caused by hair and earrings. We present a complete system for ear biometrics, including automated segmentation of the ear in a profile view image and 3D shape matching for recognition. We evaluated this system with the largest experimental study to date in ear biometrics, achieving a rank-one recognition rate of 97.8 percent for an identification scenario and an equal error rate of 1.2 percent for a verification scenario on a database of 415 subjects and 1,386 total probes.

  6. Intra- and interspecific responses to Rafinesque’s big-eared bat (Corynorhinus rafinesquii) social calls.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Loeb, Susan, C.; Britzke, Eric, R.

    Bats respond to the calls of conspecifics as well as to calls of other species; however, few studies have attempted to quantify these responses or understand the functions of these calls. We tested the response of Rafinesque’s big-eared bats (Corynorhinus rafinesquii) to social calls as a possible method to increase capture success and to understand the function of social calls. We also tested if calls of bats within the range of the previously designated subspecies differed, if the responses of Rafinesque’s big-eared bats varied with geographic origin of the calls, and if other species responded to the calls of C.more » rafinesquii. We recorded calls of Rafinesque’s big-eared bats at two colony roost sites in South Carolina, USA. Calls were recorded while bats were in the roosts and as they exited. Playback sequences for each site were created by copying typical pulses into the playback file. Two mist nets were placed approximately 50–500 m from known roost sites; the net with the playback equipment served as the Experimental net and the one without the equipment served as the Control net. Call structures differed significantly between the Mountain and Coastal Plains populations with calls from the Mountains being of higher frequency and longer duration. Ten of 11 Rafinesque’s big-eared bats were caught in the Control nets and, 13 of 19 bats of other species were captured at Experimental nets even though overall bat activity did not differ significantly between Control and Experimental nets. Our results suggest that Rafinesque’s big-eared bats are not attracted to conspecifics’ calls and that these calls may act as an intraspecific spacing mechanism during foraging.« less

  7. Ambient and at-the-ear occupational noise exposure and serum lipid levels.

    PubMed

    Arlien-Søborg, Mai C; Schmedes, Astrid S; Stokholm, Z A; Grynderup, M B; Bonde, J P; Jensen, C S; Hansen, Å M; Frederiksen, T W; Kristiansen, J; Christensen, K L; Vestergaard, J M; Lund, S P; Kolstad, H A

    2016-10-01

    Occupational and residential noise exposure has been related to increased risk of cardiovascular disease. Alteration of serum lipid levels has been proposed as a possible causal pathway. The objective of this study was to investigate the relation between ambient and at-the-ear occupational noise exposure and serum levels of total cholesterol, low-density lipoprotein-cholesterol, high-density lipoprotein-cholesterol, and triglycerides when accounting for well-established predictors of lipid levels. This cross-sectional study included 424 industrial workers and 84 financial workers to obtain contrast in noise exposure levels. They provided a serum sample and wore portable dosimeters that every 5-s recorded ambient noise exposure levels during a 24-h period. We extracted measurements obtained during work and calculated the full-shift mean ambient noise level. For 331 workers who kept a diary on the use of a hearing protection device (HPD), we subtracted 10 dB from every noise recording obtained during HPD use and estimated the mean full-shift noise exposure level at the ear. Mean ambient noise level was 79.9 dB (A) [range 55.0-98.9] and the mean estimated level at the ear 77.8 dB (A) [range 55.0-94.2]. Ambient and at-the-ear noise levels were strongly associated with increasing levels of triglycerides, cholesterol-HDL ratio, and decreasing levels of HDL-cholesterol, but only in unadjusted analyses that did not account for HPD use and other risk factors. No associations between ambient or at-the-ear occupational noise exposure and serum lipid levels were observed. This indicates that a causal pathway between occupational and residential noise exposure and cardiovascular disease does not include alteration of lipid levels.

  8. Implementing electronic identification for performance recording in sheep: I. Manual versus semiautomatic and automatic recording systems in dairy and meat farms.

    PubMed

    Ait-Saidi, A; Caja, G; Salama, A A K; Carné, S

    2014-12-01

    With the aim of assessing the secondary benefits of using electronic identification (e-ID) in sheep farms, we compared the use of manual (M), semiautomatic (SA), and automatic (AU) data-collection systems for performance recording (i.e., milk, lambing, and weight) in 3 experiments. Ewes were identified with visual ear tags and electronic rumen boluses. The M system consisted of visual ear tags, on-paper data recording, and manual data uploading to a computer; the use of a personal digital assistant (PDA) for data recording and data uploading was also done in M. The SA system used a handheld reader (HHR) for e-ID, data recording, and uploading. Both PDA and HHR used Bluetooth for uploading. The AU system was only used for body weight recording and consisted of e-ID, data recording in an electronic scale, and data uploading. In experiment 1, M and SA milk-recording systems were compared in a flock of 48 dairy ewes. Ewes were milked once- (×1, n=24) or twice- (×2, n=24) daily in a 2 × 12 milking parlor and processed in groups of 24. Milk yield (1.21 ± 0.04 L/d, on average) was 36% lower in ×1 than ×2 ewes and milk recording time correlated positively with milk yield (R(2)=0.71). Data transfer was markedly faster for PDA and HHR than for M. As a result, overall milk recording time was faster in SA (×1=12.1 ± 0.6 min/24 ewes; ×2=22.1 ± 0.9 min/24 ewes) than M (×1=14.9 ± 0.6 min/24 ewes; ×2=27.9 ± 1.0 min/24 ewes). No differences between PDA and HHR were detected. Time savings, with regard to M, were greater for ×2 than for ×1 (5.6 ± 0.2 vs. 2.8 ± 0.1 min per 24 ewes, respectively), but similar for PDA and HHR. Data transfer errors averaged 3.6% in M, whereas no errors were found in either SA system. In experiment 2, 73 dairy and 80 meat ewes were monitored at lambing using M and SA. Overall time for lambing recording was greater in M than SA in dairy (1.67 ± 0.06 vs. 0.87 ± 0.04 min/ewe) and meat (1.30 ± 0.03 vs. 0.73 ± 0.03 min/ewe) ewes. Recording errors were greater in dairy (9.6%) than in meat (1.9%) ewes. Data uploading errors only occurred in M (4.9%). In experiment 3, 120 dairy and 120 meat ewes were weighed using M and AU systems. In both flocks, mean BW recording and data uploading times, as well as overall BW recording time (0.63 ± 0.02 and 0.25 ± 0.01 min/ewe, respectively) were greater in M than in AU, and uploading errors only occurred in M (8.8%). In conclusion, HHR and PDA systems were time-effective for performance recording, both saving time and improving data accuracy. Working load and time for ewe identification were faster in HHR but it did not affect the performance recording time. The PDA was the fastest device for data download. Further research will evaluate the costs of implementing e-ID for performance recording and other uses in sheep farms. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  9. New records and notes on the ecology of the northern long-eared bat (Myotis septentrionalis) in Arkansas

    Treesearch

    D.B. Sasse; M.L. Caviness; M.J. Harvey; J.L. Jackson; P.N. Jordan; T.L. Klotz; P.R. Moore; R.W. Perry; R.K. Redman; T.S. Risch; D.A. Saugey; J.D. Wilhide

    2014-01-01

    The northern long-eared bat (Myotis septentrionalis) has been a common insectivorous bat in much of eastern North America, including Arkansas, which is located near the southwestern edge of its range. While this species is expected to occur throughout the Ozarks and Ouachita Mountains, it has only been previously documented in 19 of 75 Arkansas...

  10. 15 CFR 762.2 - Records to be retained.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... minimis calculation (method). (c) Special recordkeeping requirement—(1) Libya. Persons in receipt of a... the export to Libya of any item subject to the EAR must maintain a record of those items transferred to Libya pursuant to such specific license and record when the items are consumed or destroyed in the...

  11. 15 CFR 762.2 - Records to be retained.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... minimis calculation (method). (c) Special recordkeeping requirement—(1) Libya. Persons in receipt of a... the export to Libya of any item subject to the EAR must maintain a record of those items transferred to Libya pursuant to such specific license and record when the items are consumed or destroyed in the...

  12. Do high sound pressure levels of crowing in roosters necessitate passive mechanisms for protection against self-vocalization?

    PubMed

    Claes, Raf; Muyshondt, Pieter G G; Dirckx, Joris J J; Aerts, Peter

    2018-02-01

    High sound pressure levels (>120dB) cause damage or death of the hair cells of the inner ear, hence causing hearing loss. Vocalization differences are present between hens and roosters. Crowing in roosters is reported to produce sound pressure levels of 100dB measured at a distance of 1m. In this study we measured the sound pressure levels that exist at the entrance of the outer ear canal. We hypothesize that roosters may benefit from a passive protective mechanism while hens do not require such a mechanism. Audio recordings at the level of the entrance of the outer ear canal of crowing roosters, made in this study, indeed show that a protective mechanism is needed as sound pressure levels can reach amplitudes of 142.3dB. Audio recordings made at varying distances from the crowing rooster show that at a distance of 0.5m sound pressure levels already drop to 102dB. Micro-CT scans of a rooster and chicken head show that in roosters the auditory canal closes when the beak is opened. In hens the diameter of the auditory canal only narrows but does not close completely. A morphological difference between the sexes in shape of a bursa-like slit which occurs in the outer ear canal causes the outer ear canal to close in roosters but not in hens. Copyright © 2017 Elsevier GmbH. All rights reserved.

  13. Single-channel in-ear-EEG detects the focus of auditory attention to concurrent tone streams and mixed speech

    NASA Astrophysics Data System (ADS)

    Fiedler, Lorenz; Wöstmann, Malte; Graversen, Carina; Brandmeyer, Alex; Lunner, Thomas; Obleser, Jonas

    2017-06-01

    Objective. Conventional, multi-channel scalp electroencephalography (EEG) allows the identification of the attended speaker in concurrent-listening (‘cocktail party’) scenarios. This implies that EEG might provide valuable information to complement hearing aids with some form of EEG and to install a level of neuro-feedback. Approach. To investigate whether a listener’s attentional focus can be detected from single-channel hearing-aid-compatible EEG configurations, we recorded EEG from three electrodes inside the ear canal (‘in-Ear-EEG’) and additionally from 64 electrodes on the scalp. In two different, concurrent listening tasks, participants (n  =  7) were fitted with individualized in-Ear-EEG pieces and were either asked to attend to one of two dichotically-presented, concurrent tone streams or to one of two diotically-presented, concurrent audiobooks. A forward encoding model was trained to predict the EEG response at single EEG channels. Main results. Each individual participants’ attentional focus could be detected from single-channel EEG response recorded from short-distance configurations consisting only of a single in-Ear-EEG electrode and an adjacent scalp-EEG electrode. The differences in neural responses to attended and ignored stimuli were consistent in morphology (i.e. polarity and latency of components) across subjects. Significance. In sum, our findings show that the EEG response from a single-channel, hearing-aid-compatible configuration provides valuable information to identify a listener’s focus of attention.

  14. A comparison of tympanometry with 226 Hz and 1000 Hz probe tones in children with Down syndrome.

    PubMed

    Lewis, Meagan P; Bradford Bell, Elizabeth; Evans, Adele K

    2011-12-01

    For children with Down syndrome, the incidence of hearing loss may be as high as 78% [1], therefore the American Academy of Pediatrics recommends regular screening for the presence of hearing abnormalities. Tympanometry is used as an indication of middle ear pathology. In our experience, Down's patients' tympanograms do not always correlate with otoscopic findings. Down's patients have joint laxity, small ear canals, anterior tympanic membrane orientation and softer tissue composition, all factors thought to affect tympanogram results in infants. Because the use of the 1000 Hz tympanometry is widely recognized as standard procedure in the evaluation of infants aged 0-6 months, we propose it may have greater reliability in testing patients with Down syndrome. Compare the results of visual inspection of the tympanic membrane by a Pediatric Otolaryngologist to the results of tympanometry at traditional probe tone (226 Hz) and at the infant probe tone (1000 Hz). Institutional Review Board - approved prospective study of 26 subject-ears in patients with Down syndrome aged 6 months-18 years but recent stable middle ear/Eustachian tube function using physical examination and tympanometric probe tones at 226 Hz and 1000 Hz. Subject-ears were examined with record of "clear of effusion," showed the presence of "fluid," or were to be "excluded." Blinded to ear exam results, tympanometry was then completed with record of which Jerger classification tympanogram was found at each frequency. Although the sensitivity of each test was 1, the specificity of the 1000 Hz tympanometry (100%) in this study was markedly improved compared to the specificity of the 226 Hz tympanometry (71%) (p=0.016). This pilot study demonstrated evidence that tympanometry in children with Down syndrome may be more reliable at 1000 Hz than at 226 Hz in detecting the presence of middle ear effusion beyond infancy. Use of the 1000 Hz probe tone yielded fewer false positives for disease (type B tympanograms in the setting of absent middle ear disease). Further studies of a larger patient population are needed to corroborate these results. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  15. Do weaner pigs need in-feed antibiotics to ensure good health and welfare?

    PubMed Central

    Manzanilla, Edgar G.; Calderón Díaz, Julia A.; Leonard, Finola C.; Boyle, Laura A.

    2017-01-01

    Antibiotics (AB) are used in intensive pig production systems to control infectious diseases and they are suspected to be a major source of antibiotic resistance. Following the ban on AB use as growth promoters in the EU, their prophylactic use in-feed is now under review. The aim of this study was to evaluate the effect of removing prophylactic in-feed AB on pig health and welfare indicators. Every Monday for six weeks, a subset of 70 pigs were weaned, tagged and sorted into two groups of 35 pigs according to weight (9.2 ± 0.6 kg). AB were removed from the diet of one group (NO, n = 6) and maintained in the other group (AB, n = 6) for nine weeks. Ten focal pigs were chosen per group. After c. five weeks each group was split into two pens of c.17 pigs for the following 4 weeks. Data were recorded weekly. Skin, tail, ear, flank and limb lesions of focal pigs were scored according to severity. The number of animals per group affected by health deviations was also recorded. The number of fights and harmful behaviours (ear, tail bites) per group was counted during 3×5min observations once per week. Data were analysed using mixed model equations and binomial logistic regression. At group level, AB pigs were more likely to have tail (OR = 1.70; P = 0.05) but less likely to have ear lesions than NO pigs (OR = 0.46; P<0.05). The number of ear bites (21.4±2.15 vs. 17.3±1.61; P<0.05) and fights (6.91±0.91 vs. 5.58±0.72; P = 0.09) was higher in AB than in NO pigs. There was no effect of treatment on health deviations and the frequency of these was low. Removing AB from the feed of weaner pigs had minimal effects on health and welfare indicators. PMID:28982114

  16. Do weaner pigs need in-feed antibiotics to ensure good health and welfare?

    PubMed

    Diana, Alessia; Manzanilla, Edgar G; Calderón Díaz, Julia A; Leonard, Finola C; Boyle, Laura A

    2017-01-01

    Antibiotics (AB) are used in intensive pig production systems to control infectious diseases and they are suspected to be a major source of antibiotic resistance. Following the ban on AB use as growth promoters in the EU, their prophylactic use in-feed is now under review. The aim of this study was to evaluate the effect of removing prophylactic in-feed AB on pig health and welfare indicators. Every Monday for six weeks, a subset of 70 pigs were weaned, tagged and sorted into two groups of 35 pigs according to weight (9.2 ± 0.6 kg). AB were removed from the diet of one group (NO, n = 6) and maintained in the other group (AB, n = 6) for nine weeks. Ten focal pigs were chosen per group. After c. five weeks each group was split into two pens of c.17 pigs for the following 4 weeks. Data were recorded weekly. Skin, tail, ear, flank and limb lesions of focal pigs were scored according to severity. The number of animals per group affected by health deviations was also recorded. The number of fights and harmful behaviours (ear, tail bites) per group was counted during 3×5min observations once per week. Data were analysed using mixed model equations and binomial logistic regression. At group level, AB pigs were more likely to have tail (OR = 1.70; P = 0.05) but less likely to have ear lesions than NO pigs (OR = 0.46; P<0.05). The number of ear bites (21.4±2.15 vs. 17.3±1.61; P<0.05) and fights (6.91±0.91 vs. 5.58±0.72; P = 0.09) was higher in AB than in NO pigs. There was no effect of treatment on health deviations and the frequency of these was low. Removing AB from the feed of weaner pigs had minimal effects on health and welfare indicators.

  17. Technical innovations in ear reconstruction using a skin expander with autogenous cartilage grafts.

    PubMed

    Dashan, Yu; Haiyue, Jiang; Qinghua, Yang; Bo, Pan; Lin, Lin; Tailing, Wang; Yanmei, Wang; Xiao, Qin; Hongxing, Zhuang

    2008-01-01

    Pioneers such as Tanzer and Brent have established the foundations of microtia reconstruction using an autogenous costal cartilage framework. The framework and its skin coverage are the two limiting factors in ear reconstruction. At the present time autogenous rib cartilage and mastoid skin are still first choice materials for most surgeons. They have the combined advantages of well-matched texture and colour. To reconstruct a symmetrical, accurate, prominent auricle and minimise as much as possible the chest wall deformity caused by rib cartilage harvesting, we set out to improve our techniques for cartilaginous framework definition and to use the remnant ear to enhance the projection of the reconstructed ear. Since 2000, 342 cases (366 ears) were treated using our current techniques. Data pertaining to complications were recorded. Final results were assessed a minimum of 1 year postoperatively. The follow-up period ranged from 1 to 6 years. Most of the patients with microtia were satisfied with the results of their ear reconstruction. In conclusion, our techniques help to reduce the quantity of rib cartilage needed to fabricate ear framework and minimise chest wall deformity. The frameworks are accurate, prominent and stable. Reconstructed ears are similar in colour and appearance to the normal side. Our innovations are practical and reliable for microtia reconstruction using skin expanders in combination with a sculpted autogenous rib cartilage framework.

  18. Mirror ear: a reconstructive technique for substantial tragal anomalies or polyotia.

    PubMed

    Gore, Sinclair M; Myers, Simon R; Gault, David

    2006-01-01

    Polyotia (mirror ear) is an extremely rarely reported congenital anomaly of the external ear. The aetiology of this condition is unclear, and there are few descriptions of surgical techniques used. We aimed to review our experience with this condition by performing a retrospective review of the cases treated in our unit. Eight cases of polyotia treated at a referral centre for ear reconstruction in a 12 year period (1992-2004) were reviewed. Patient demographic data and associated syndromes were recorded. Operative techniques used in the cases were studied. There was an equal number of males and females. Four patients had abnormal contralateral ears and two patients were formally diagnosed as suffering from a congenital developmental syndrome. Five main components of surgical technique were found to be particularly relevant to these cases. These relate to deconstruction of the defect, management of extra cartilage, management of skin, proximity of the facial nerve and the timing of surgery. The authors conclude that a structured surgical approach can lead to successful reconstruction of these difficult abnormalities.

  19. iPhone otoscopes: Currently available, but reliable for tele-otoscopy in the hands of parents?

    PubMed

    Shah, Manan Udayan; Sohal, Maheep; Valdez, Tulio A; Grindle, Christopher R

    2018-03-01

    Tele-otoscopy has been validated for tympanostomy surveillance and remote diagnosis when images are recorded by trained professionals. The CellScope iPhone Otoscope is a device that may be used for tele-otoscopy and it enables parents to record their children's ear examinations and send the films for remote physician diagnosis. This study aims to determine the ability to diagnose, and the reliability of the diagnosis when utilizing video exams obtained by a parent versus video exams obtained by an otolaryngologist. Parents of children ages 17 years or younger attempted recordings of the tympanic membrane of their children with the CellScope after a video tutorial; a physician subsequently used the device to record the same ear. Recordings occurred prior to standard pediatric otolaryngology office evaluation. Later, a remote pediatric otolaryngologist attempted diagnosis solely based on the videos, blinded to whether the examination was filmed by a parent or physician. Interrater reliability between video diagnosis and original diagnosis on pneumatic otoscopy was measured, and objective tympanic membrane landmarks visualized on the films were recorded. Eighty ears were enrolled and recorded. There was low interrater agreement (k = 0.42) between diagnosis based on parent videos as compared with pneumatic otoscopy. There was high agreement (k = 0.71) between diagnosis based on physician videos and pneumatic otoscopy. Physician videos and parent videos had only slight agreement on objective landmarks identified (k = 0.087). iPhone otoscopy provides reliable tele-otoscopy images in when used by trained professionals but, currently, images obtained by parents are not suitable for use in diagnosis. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Biological Terrorism Preparedness: Evaluating the Performance of the Early Aberration Reporting System (EARS) Syndromic Surveillance Algorithms

    DTIC Science & Technology

    2007-06-01

    PREPAREDNESS: EVALUATING THE PERFORMANCE OF THE EARLY ABERRATION REPORTING SYSTEM (EARS) SYNDROMIC SURVEILLANCE ALGORITHMS by David A...SUBTITLE Biological Terrorism Preparedness: Evaluating the Performance of the Early Aberration Reporting System (EARS) Syndromic Surveillance...Algorithms 6. AUTHOR(S) David Dunfee, Benjamin Hegler 5. FUNDING NUMBERS 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) Naval Postgraduate School

  1. Naturalistically observed conflict and youth asthma symptoms.

    PubMed

    Tobin, Erin T; Kane, Heidi S; Saleh, Daniel J; Naar-King, Sylvie; Poowuttikul, Pavadee; Secord, Elizabeth; Pierantoni, Wayne; Simon, Valerie A; Slatcher, Richard B

    2015-06-01

    To investigate the links between naturalistically observed conflict, self-reported caregiver-youth conflict, and youth asthma symptoms. Fifty-four youth with asthma (age range: 10-17 years) wore the Electronically Activated Recorder (EAR) for a 4-day period to assess interpersonal conflict and caregiver-youth conflict as they occur in daily life. Conflict also was assessed with baseline self-report questionnaires and daily diaries completed by youth participants and their caregivers. Asthma symptoms were assessed using daily diaries, baseline self-reports, and wheezing, as coded from the EAR. EAR-observed measures of conflict were strongly associated with self-reported asthma symptoms (both baseline and daily diaries) and wheezing coded from the EAR. Further, when entered together in regression analyses, youth daily reports of negative caregiver-youth interactions and EAR-observed conflict uniquely predicted asthma symptoms; only EAR-observed conflict was associated with EAR-observed wheezing. These findings demonstrate the potential impact of daily conflict on youth asthma symptoms and the importance of assessing conflict as it occurs in everyday life. More broadly, they point to the importance of formulating a clear picture of family interactions outside of the lab, which is essential for understanding how family relationships "get under the skin" to affect youth health. (c) 2015 APA, all rights reserved).

  2. Naturalistically-Observed Conflict and Youth Asthma Symptoms

    PubMed Central

    Tobin, Erin T.; Kane, Heidi S.; Saleh, Daniel J.; Naar-King, Sylvie; Poowuttikul, Pavadee; Secord, Elizabeth; Pierantoni, Wayne; Simon, Valerie; Slatcher, Richard B.

    2014-01-01

    Objective To investigate the links between naturalistically-observed conflict, self-reported caregiver-youth conflict, and youth asthma symptoms. Method Fifty-four youth with asthma (aged 10-17) wore the Electronically Activated Recorder (EAR) for a 4-day period to assess interpersonal conflict and caregiver-youth conflict as they occur in daily life. Conflict also was assessed with baseline self-report questionnaires and daily diaries completed by the youth participants and their caregiver. Asthma symptoms were assessed via daily diaries and baseline self-reports and wheezing as coded from the EAR. Results EAR-observed measures of conflict were strongly associated with self-reported asthma symptoms (both baseline and daily diaries) and wheezing coded from the EAR. Further, when entered together in regression analyses, youth daily reports of negative caregiver-youth interactions and EAR-observed conflict uniquely predicted asthma symptoms; only EAR-observed conflict was associated with EAR-observed wheezing. Conclusions These findings demonstrate the potential impact of daily conflict on youth asthma symptoms and the importance of assessing conflict as it occurs in everyday life. More broadly, they point to the importance of formulating a clear picture of family interactions outside of the lab, which is essential for understanding how family relationships “get under the skin” to affect youth health. PMID:25222090

  3. Mozart Ear Deformity: a Rare Diagnosis in the Ear Reconstruction Clinic.

    PubMed

    Telich-Tarriba, Jose E; Victor-Baldin, Andre; Apellaniz-Campo, Armando

    2017-07-01

    Mozart ear is a rare auricular deformity; clinically the auricle is characterized by the bulging appearance of the anterosuperior portion of the auricle due to fusion of the crura of the antihelix, an inversion in the normal form of the cavum conchae resulting in its convexity and a slit-like narrowing of the orifice of the external auditory meatus.A retrospective review of clinical and photographic records of patients attended at the ear reconstruction clinic of our hospital between June of 2010 and May 2016 was performed; out of 576 consecutive patients only 3 fulfilled the inclusion criteria, with a prevalence of 0.5%. The authors present these patients.Surgical interventions mainly focus on the correction of the convex concha; however, the procedure should be tailored to the severity of the deformity and the wishes of the patient.

  4. Squid 'ear bones' (statoliths) from the Jurassic succession of South-west England

    NASA Astrophysics Data System (ADS)

    Hart, Malcolm; Page, Kevin; Price, Gregory; Smart, Christopher

    2015-04-01

    Squid 'ear bones' - or statoliths - are a part of the balancing organs of modern and probably most fossil squids. Over the course of the last 10 years fossil statoliths have been discovered in the Jurassic sediments of the Wessex Basin (South-west England). They are probably all related to teuthids, such as Belemnotheutis antiquus Pearce, of Callovian-Oxfordian age. Thus far, we have identified four possible 'species' of statolith that are in the process of being formally described, named and their potential relationships determined. The sediments from which these statoliths have been recorded also contain squid hooklets (onycites), otoliths (fish 'ear bones') and other microfossils (including foraminifera). All are, therefore, of marine origin. In the case of the Christian Malford and Ashton Keynes lagerstätte (of late Callovian age), the statoliths are associated with exceptional, soft-bodied preservation of squid and it may be possible to determine the parent animal of the recorded statoliths. A number of museum collections (Natural History Museum [London], Natural History Museum [Paris], Senckenberg [Frankfurt], Smithsonian Institution [Washington], etc.) are being investigated in order to trace the possible host animals for all of the recorded statoliths. Despite many thousands of samples of Cretaceous sediments being investigated for foraminifera over the past 40+ years, no statoliths have been recorded and none are known from the literature.

  5. Sound attenuation in the ear of domestic chickens (Gallus gallus domesticus) as a result of beak opening

    PubMed Central

    Claes, Raf; Dirckx, Joris J. J.

    2017-01-01

    Because the quadrate and the eardrum are connected, the hypothesis was tested that birds attenuate the transmission of sound through their ears by opening the bill, which potentially serves as an additional protective mechanism for self-generated vocalizations. In domestic chickens, it was examined if a difference exists between hens and roosters, given the difference in vocalization capacity between the sexes. To test the hypothesis, vibrations of the columellar footplate were measured ex vivo with laser Doppler vibrometry (LDV) for closed and maximally opened beak conditions, with sounds introduced at the ear canal. The average attenuation was 3.5 dB in roosters and only 0.5 dB in hens. To demonstrate the importance of a putative protective mechanism, audio recordings were performed of a crowing rooster. Sound pressures levels of 133.5 dB were recorded near the ears. The frequency content of the vocalizations was in accordance with the range of highest hearing sensitivity in chickens. The results indicate a small but significant difference in sound attenuation between hens and roosters. However, the amount of attenuation as measured in the experiments on both hens and roosters is small and will provide little effective protection in addition to other mechanisms such as stapedius muscle activity. PMID:29291112

  6. Distortion product otoacoustic emission suppression tuning and acoustic admittance in human infants: Birth through 6 months

    PubMed Central

    Abdala, Carolina; Keefe, Douglas H.; Oba, Sandra I.

    2009-01-01

    Previous work has reported non-adultlike distortion product otoacoustic emission (DPOAE) suppression in human newborns at f2 =6000 Hz, indicating an immaturity in peripheral auditory function. In this study, DPOAE suppression tuning curves (STCs) were recorded as a measure of cochlear function and acoustic admittance/reflectance (YR) in the ear canal recorded as a measure of middle-ear function, in the same 20 infants at birth and through 6 months of age. DPOAE STCs changed little from birth through 6 months, showing excessively narrow and sharp tuning throughout the test period. In contrast, several middle-ear indices at corresponding frequencies shifted systematically with increasing age, although they also remained non-adultlike at 6 months. Linear correlations were conducted between YR and DPOAE suppression features. Only two correlations out of 76 were significant, and all but three YR variables accounted for <10% of the variance in DPOAE suppression tuning. The strongest correlation was noted between admittance phase at 5700 Hz and STC tip-to-tail (R=0.49). The association between middle-ear variables and DPOAE suppression may be stronger during other developmental time periods. Study of older infants and children is needed to fully define postnatal immaturity of human peripheral auditory function. PMID:17552713

  7. Inner ear disorders.

    PubMed

    Smouha, Eric

    2013-01-01

    To present a framework for the diagnosis and treatment of inner ear disorders, with an emphasis on problems common to neuro-rehabilitation. Disorders of the inner ear can cause hearing loss, tinnitus, vertigo and imbalance. Hearing loss can be conductive, sensorineural, or mixed; conductive hearing loss arises from the ear canal or middle ear, while sensorineural hearing loss arises from the inner ear or auditory nerve. Vertigo is a hallucination of motion, and is the cardinal symptom of vestibular system disease. It should be differentiated from other causes of dizziness: gait imbalance, disequilibrium, lightheadedness (pre-syncope). Vertigo can be caused by problems in the inner ear or central nervous system. The diagnosis of inner ear disorders begins with a targeted physical examination. The initial work-up of hearing loss is made by audiometry, and vertigo by electronystagmography (ENG). Supplemental tests and MRI are obtained when clinically indicated. The clinical pattern and duration of vertigo are the most important clinical features in the diagnosis. Common inner ear causes of vertigo include: vestibular neuritis (sudden, unilateral vestibular loss), Meniere's disease (episodic vertigo), benign paroxysmal positional vertigo (BPPV), and bilateral vestibular loss. Common central nervous system causes of vertigo include: post concussion syndrome, cervical vertigo, vestibular migraine, cerebrovascular disease, and acoustic neuroma. A basic knowledge of vestibular physiology, coupled with a understanding of common vestibular syndromes, will lead to correct diagnosis and treatment in most cases.

  8. 15 CFR 762.2 - Records to be retained.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... prior approval on a BIS or DDTC license (STA). (c) Special recordkeeping requirement—(1) Libya. Persons... Control (OFAC) for the export to Libya of any item subject to the EAR must maintain a record of those items transferred to Libya pursuant to such specific license and record when the items are consumed or...

  9. Valence of physical stimuli, not housing conditions, affects behaviour and frontal cortical brain activity in sheep.

    PubMed

    Vögeli, Sabine; Lutz, Janika; Wolf, Martin; Wechsler, Beat; Gygax, Lorenz

    2014-07-01

    Modulation of short-term emotions by long-term mood is little understood but relevant to understand the affective system and of importance in respect to animal welfare: a negative mood might taint experiences, whilst a positive mood might alleviate single negative events. To induce different mood states in sheep housing conditions were varied. Fourteen ewes were group-housed in an unpredictable, stimulus-poor and 15 ewes in a predictable, stimulus-rich environment. Sheep were tested individually for mood in a behavioural cognitive bias paradigm. Also, their reactions to three physical stimuli thought to differ in their perceived valence were observed (negative: pricking, intermediate: slight pressure, positive: kneading). General behaviour, activity, ear movements and positions, and haemodynamic changes in the cortical brain were recorded during stimulations. Generalised mixed-effects models and model probabilities based on the BIC (Bayesian information criterion) were used. Only weak evidence for mood difference was found. Sheep from the unpredictable, stimulus-poor housing condition had a somewhat more negative cognitive bias, showed slightly more aversive behaviour, were slightly more active and moved their ears somewhat more. Sheep most clearly differentiated the negative from the intermediate and positive stimulus in that they exhibited more aversive behaviour, less nibbling, were more active, showed more ear movements, more forward ear postures, fewer backward ear postures, and a stronger decrease in deoxyhaemoglobin when subjected to the negative stimulus. In conclusion, sheep reacted towards stimuli according to their presumed valence but their mood was not strongly influenced by housing conditions. Therefore, behavioural reactions and cortical brain activity towards the stimuli were hardly modulated by housing conditions. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Immunologic Disorders of the Inner Ear.

    ERIC Educational Resources Information Center

    Kinney, William C.; Hughes, Gordon B.

    1997-01-01

    Immune inner ear disease represents a series of immune system mediated problems that can present with hearing loss, dizziness, or both. The etiology, presentation, testing, and treatment of primary immune inner ear disease is discussed. A review of secondary immune inner ear disease is presented for comparison. (Contains references.) (Author/CR)

  11. Comparison of muzzle suppression and ear-level hearing protection in firearm use.

    PubMed

    Branch, Matthew Parker

    2011-06-01

    To compare noise reduction of commercially available ear-level hearing protection (muffs/inserts) to that of firearm muzzle suppressors. Experimental sound measurements under consistent environmental conditions. None. Muzzle suppressors for 2 pistol and 2 rifle calibers were tested using the Bruel & Kjaer 2209 sound meter and Bruel & Kjaer 4136 microphone calibrated with the Bruel & Kjaer Pistonphone using Military-Standard 1474D placement protocol. Five shots were recorded unsuppressed and 10 shots suppressed under consistent environmental conditions. Sound reduction was then compared with the real-world noise reduction rate of the best available ear-level protectors. All suppressors offered significantly greater noise reduction than ear-level protection, usually greater than 50% better. Noise reduction of all ear-level protectors is unable to reduce the impulse pressure below 140 dB for certain common firearms, an international standard for prevention of sensorineural hearing loss. Modern muzzle-level suppression is vastly superior to ear-level protection and the only available form of suppression capable of making certain sporting arms safe for hearing. The inadequacy of standard hearing protectors with certain common firearms is not recognized by most hearing professionals or their patients and should affect the way hearing professionals counsel patients and the public.

  12. Initial assessment of hearing loss using a mobile application for audiological evaluation.

    PubMed

    Derin, S; Cam, O H; Beydilli, H; Acar, E; Elicora, S S; Sahan, M

    2016-03-01

    This study aimed to compare an Apple iOS mobile operating system application for audiological evaluation with conventional audiometry, and to determine its accuracy and reliability in the initial evaluation of hearing loss. The study comprised 32 patients (16 females) diagnosed with hearing loss. The patients were first evaluated with conventional audiometry and the degree of hearing loss was recorded. Then they underwent a smartphone-based hearing test and the data were compared using Cohen's kappa analysis. Patients' mean age was 53.59 ± 18.01 years (range, 19-85 years). The mobile phone audiometry results for 39 of the 64 ears were fully compatible with the conventional audiometry results. There was a statistically significant concordant relationship between the two sets of audiometry results (p < 0.05). Ear Trumpet version 1.0.2 is a compact and simple mobile application on the Apple iPhone 5 that can measure hearing loss with reliable results.

  13. Analysis of otoacoustic emissions in neonates at term and preterm.

    PubMed

    Cavalcante, Juliana Maria Soares; Isaac, Myriam de Lima

    2013-01-01

    The transient evoked otoacoustic emissions (TEOAEs) have been widely used in neonatal hearing screening. To compare the TEOAEs in newborns at term and preterm vis-à-vis the following variables: ear side, gender, frequency spectrum and gestational age. By means of a cross-sectional cohort of 66 newborns up to the 28th day of life (41 newborns at term and 25 premature babies), we recorded TEOAEs. All the individuals did not have risk indicators for hearing loss. There was a signal/noise ratio improvement with frequency increase. No differences were observed between genders and between the ears, but there were differences among the children born at term and preterm in the frequency bands at 3 kHz and 4 kHz. The TEOAEs test is important for assessing the peripheral auditory system of newborns at term and preterm, making it possible to have responses regardless of gender and gestational age.

  14. Asymmetry of temporal auditory T-complex: right ear-left hemisphere advantage in Tb timing in children.

    PubMed

    Bruneau, Nicole; Bidet-Caulet, Aurélie; Roux, Sylvie; Bonnet-Brilhault, Frédérique; Gomot, Marie

    2015-02-01

    To investigate brain asymmetry of the temporal auditory evoked potentials (T-complex) in response to monaural stimulation in children compared to adults. Ten children (7 to 9 years) and ten young adults participated in the study. All were right-handed. The auditory stimuli used were tones (1100 Hz, 70 dB SPL, 50 ms duration) delivered monaurally (right, left ear) at four different levels of stimulus onset asynchrony (700-1100-1500-3000 ms). Latency and amplitude of responses were measured at left and right temporal sites according to the ear stimulated. Peaks of the three successive deflections (Na-Ta-Tb) of the T-complex were greater in amplitude and better defined in children than in adults. Amplitude measurements in children indicated that Na culminates on the left hemisphere whatever the ear stimulated whereas Ta and Tb culminate on the right hemisphere but for left ear stimuli only. Peak latency displayed different patterns of asymmetry. Na and Ta displayed shorter latencies for contralateral stimulation. The original finding was that Tb peak latency was the shortest at the left temporal site for right ear stimulation in children. Amplitude increased and/or peak latency decreased with increasing SOA, however no interaction effect was found with recording site or with ear stimulated. Our main original result indicates a right ear-left hemisphere timing advantage for Tb peak in children. The Tb peak would therefore be a good candidate as an electrophysiological marker of ear advantage effects during dichotic stimulation and of functional inter-hemisphere interactions and connectivity in children. Copyright © 2014. Published by Elsevier B.V.

  15. Eye and Ear Temperature Using Infrared Thermography Are Related to Rectal Temperature in Dogs at Rest or With Exercise.

    PubMed

    Zanghi, Brian M

    2016-01-01

    Rectal body temperature (BT) has been documented in exercising dogs to monitor thermoregulation, heat stress risk, and performance during physical activity. Eye (BT eye ) and ear (BT ear ) temperature measured with infrared thermography (IRT) were compared to rectal (BT rec ) temperature as the reference method and assess alternative sites to track hyperthermia, possibly to establish BT eye IRT as a passive and non-contact method. BT measures were recorded at 09:00, 11:30, 12:30, and 02:30 from Labrador Retrievers ( N  = 16) and Beagles ( N  = 16) while sedentary and with 30-min play-exercise (pre- and 0, 15, 30-min post-exercise). Total exercise locomotor activity counts were recorded to compare relative intensity of play-exercise between breeds. BT rec , BT eye , and BT ear were measured within 5 min of the target time. Each BT method was analyzed by analysis of variance for main effects of breed and time. Method differences were compared using Bland-Altman plots and linear regression. Sedentary BT differed by breed for BT rec ( p  < 0.0001), BT ear ( p  < 0.0001), and BT eye ( p  = 0.06) with Labs having on average 0.3-0.8°C higher BT compared to Beagles. Readings also declined over time for BT eye ( p  < 0.0001) and BT ear ( p  < 0.0001), but not for BT rec ( p  = 0.63) for both breeds. Total exercise (30-min) activity counts did not differ ( p  = 0.53) between breeds. Time and breed interaction was significant in response to exercise for both BT rec and BT ear ( p  = 0.035 and p  = 0.005, respectively), with a marginal interaction ( p  = 0.09) for BT eye . All the three methods detected hyperthermia with Labs having a higher increase compared to Beagles. Both BT ear and BT eye were significantly ( p  < 0.0001) related to BT rec in all dogs with sedentary or exercise activity. The relationship between BT eye and BT rec improved when monitoring exercise hyperthermia ( r  = 0.674) versus measures at rest ( r  = 0.381), whereas BT ear was significantly related to BT rec regardless of activity ( r  = 0.615-0.735). Although BT readings were significantly related, method bias ( p  < 0.02) was observed for BT eye to slightly underestimate BT rec , whereas no bias was observed between BT ear and BT rec . This study demonstrates that IRT technology effectively measures both ear and eye temperature and enables effective monitoring of BT changes at rest, with exercise, and between breeds. However, ear, and not eye, temperature is a better reflection of rectal temperature.

  16. Effects of a suppressor tone on distortion product otoacoustic emissions fine structure: why a universal suppressor level is not a practical solution to obtaining single-generator DP-grams.

    PubMed

    Dhar, Sumitrajit; Shaffer, Lauren A

    2004-12-01

    The use of a suppressor tone has been proposed as the method of choice in obtaining single-generator distortion product (DP) grams, the speculation being that such DP grams will be more predictive of hearing thresholds. Current distortion product otoacoustic emissions (DPOAE) theory points to the ear canal DPOAE signal being a complex interaction between multiple components. The effectiveness of a suppressor tone is predicted to be dependent entirely on the relative levels of these components. We examine the validity of using a suppressor tone through a detailed examination of the effects of a suppressor on DPOAE fine structure in individual ears. DPOAE fine structure, recorded in 10 normal-hearing individuals with a suppressor tone at 45, 55, and 65 dB SPL, was compared with recordings without a suppressor. Behavioral hearing thresholds were also measured in the same subjects, using 2-dB steps. The effect of the suppressor tone on DPOAE fine structure varied between ears and was dependent on frequency within ears. Correlation between hearing thresholds and DPOAE level measured without a suppressor was similar to previous reports. The effects of the suppressor are explained in the theoretical framework of a model involving multiple DPOAE components. Our results suggest that a suppressor tone can have highly variable effects on fine structure across individuals or even across frequency within one ear, thereby making the use of a suppressor less viable as a clinical tool for obtaining single-generator DP grams.

  17. Comparison of high-resolution microendoscope images and histopathological sections in ex vivo middle ear cholesteatomas and surrounding tissue

    NASA Astrophysics Data System (ADS)

    Bradley, James; Levy, Lauren; Richards-Kortum, Rebecca; Sikora, Andrew G.; Smouha, Eric

    2013-03-01

    Objective: To investigate the concordance between optical images obtained with high-resolution microendoscopy (HRME) and conventional histopathology for ex vivo cholesteatoma specimens and surrounding middle ear epithelium. Methods: After resection of cholesteatoma and surrounding middle ear epithelium from surgical patients, tissues were stained with a contrast agent, proflavine, and the HRME fiberoptic scope was placed directly on each tissue specimen. 4- 10 short movie clips were recorded for both the cholesteatoma and surrounding middle ear epithelium specimens. The imaged areas were sent for standard histopathology, and the stained specimens were correlated with the HRME images. IRB approval was obtained, and each patient was consented for the study. Results: Ten cholesteatoma specimens and 9 middle ear specimens were collected from 10 patients. In each case, cholesteatoma was easily discriminated from normal middle ear epithelium by its hyperfluorescence and loss of cellular detail. Qualitative analysis for concordance between HRME images and histological images from the same surgical specimen yielded a strong correlation between imaging modalities. Conclusions: Keratinizing cholesteatoma and surrounding middle ear epithelium have distinct imaging characteristics. Loss of cellular detail and hyperfluorescence with proflavine are the hallmark characteristics of cholesteatoma which allow for differentiation from normal middle ear epithelium. Real-time optical imaging can potentially improve the results of otologic surgery by allowing for extirpation of cholesteatomas while eliminating residual disease. We anticipate performing an in vivo study to test this hypothesis.

  18. Synchronization of spontaneous otoacoustic emissions in the tokay gecko

    NASA Astrophysics Data System (ADS)

    Roongthumskul, Yuttana; Hudspeth, A. J.

    2018-05-01

    Spontaneous otoacoustic emissions (SOAEs) are a universal feature of all classes of tetrapods. Although the generation mechanism of SOAEs are incompletely understood, these emissions are undoubtedly associated with the active process of the inner ear. In most lizards, unlike mammals and amphibians, robust SOAEs can ordinarily be detected from both ears. In this work, we investigated the interactions between emissions recorded simultaneously from the two ears of tokay geckos. We found that the frequency spectra of SOAEs from both ears of an individual animal are partially correlated: the peaks of several emissions occur at identical frequencies. To investigate the underlying mechanisms of these identical-frequency SOAEs, we perturbed the emissions from one or both ears by manipulating the pressure in the ear canals or by decreasing the local temperature in the vicinity of one inner ear. Suppression of SOAEs due to large positive pressures revealed that some identical-frequency emissions were generated unilaterally, whereas others were contributed by both ears at identical or slightly different frequencies. These bilaterally generated SOAEs became desynchronized as their frequency detuning grew sufficiently large, a phenomenon consistent with the synchronization of two active oscillators. Finally, we found that manipulations of the volume of the oral cavity or altering the impedance of the tympanum strongly affected the synchronization of SOAEs. These findings agreed with previous studies suggesting that the tokay gecko, like other lizards, exhibits strong acoustic coupling between its tympani through the oral cavity.

  19. Nest observations of the long-eared owl (Asio otus) in Benton County, Oregon, with notes on their food habits

    Treesearch

    Richard T. Reynolds

    1970-01-01

    A nesting pair of long-eared owls was found 10 miles north of Corvallis, Benton County, Oregon, on 24 April, 1969. The pair was observed and photographed until 30 May, when the young left the nest. This is the third record of nesting Asio otus west of the Oregon Cascades. Gabrielson and Jewett (1940) reported that Pope collected eggs from a nest...

  20. Cochlear pathology in chronic suppurative otitis media.

    PubMed

    Walby, A P; Barrera, A; Schuknecht, H F

    1983-01-01

    Chronic suppurative otitis media (COM) is reported to cause elevation of bone-conduction thresholds either by damage to cochlear sensorineural structures or by alteration in the mechanics of sound transmission in the ear. A retrospective study was made of the medical records of 87 patients with unilateral uncomplicated COM to document that abnormality in bone conduction does exist. In a separate study the cochlear pathology in 12 pairs of temporal bones with unilateral COM was studied by light microscopy. Infected ears showed higher than normal mean bone-conduction thresholds by amounts ranging from 1 dB at 500 Hz to 9.5 dB at 4,000 Hz. The temporal bones showed no greater loss of specialized sensorineural structures in infected ears than in normal control ears. Because there is no evidence that COM caused destruction of hair cells or cochlear neurons, alteration in the mechanics of sound transmission becomes a more plausible explanation for the hearing losses.

  1. Influence of different boundary conditions at the tympanic annulus on finite element models of the human middle ear

    NASA Astrophysics Data System (ADS)

    Lobato, Lucas; Paul, Stephan; Cordioli, Júlio

    2018-05-01

    The tympanic annulus is a fibrocartilage ligament that supports the tympanic membrane in a sulcus at the end of the outer ear canal. Among many FE models of the middle ear found in literature, the effect of different boundary conditions at tympanic annulus on middle ear mechanics was not found. In order to investigate the influence of different representations of this detail in FE models, three different ways to connect the tympanic annulus to the outer ear canal were modelled in a reduced middle ear system. This reduced system includes tympanic membrane, tympanic annulus, manubrium, malleus and anterior ligament of malleus. The numerical frequency response function Humbo (umbo velocity vs sound pressure at tympanic membrane) was analyzed through the different boundary conditions and compared to numerical and experimental data from the literature. Also a numerical modal analysis was performed to improve the analysis. It was found that the boundary conditions used to represent the connection between Tympanic Annulus and Outer Ear Canal can change the global stiffness of the system and its natural frequencies as well as change the modal shape of high order modes.

  2. Generation of inner ear organoids containing functional hair cells from human pluripotent stem cells.

    PubMed

    Koehler, Karl R; Nie, Jing; Longworth-Mills, Emma; Liu, Xiao-Ping; Lee, Jiyoon; Holt, Jeffrey R; Hashino, Eri

    2017-06-01

    The derivation of human inner ear tissue from pluripotent stem cells would enable in vitro screening of drug candidates for the treatment of hearing and balance dysfunction and may provide a source of cells for cell-based therapies of the inner ear. Here we report a method for differentiating human pluripotent stem cells to inner ear organoids that harbor functional hair cells. Using a three-dimensional culture system, we modulate TGF, BMP, FGF, and WNT signaling to generate multiple otic-vesicle-like structures from a single stem-cell aggregate. Over 2 months, the vesicles develop into inner ear organoids with sensory epithelia that are innervated by sensory neurons. Additionally, using CRISPR-Cas9, we generate an ATOH1-2A-eGFP cell line to detect hair cell induction and demonstrate that derived hair cells exhibit electrophysiological properties similar to those of native sensory hair cells. Our culture system should facilitate the study of human inner ear development and research on therapies for diseases of the inner ear.

  3. Operational Characteristics of Two Commercially Available Personal Cooling Vests

    NASA Technical Reports Server (NTRS)

    Ku, Yu-Tsuan E.; Lee, Hank C.; Montgomery, Leslie D.; Webbon, Bruce W.; Luna, Bernadette (Technical Monitor)

    1996-01-01

    Personal thermoregulatory systems which provide chest cooling are used in the industrial and aerospace environments to alleviate thermal stress. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objectives of this study were to compare the effectiveness of two passive cooling vests, and to measure the body temperature and circulatory changes produced by each cooling vest configuration. A Life Enhancement Technologies, (LET) ice vest garment and a Steele, Inc. vest were used to cool the chest region of 11 male subjects (25 to 55 yr) in this study. Calf, forearm and finger blood flows were measured using a tetrapolar impedance rheograph. The subjects, seated in an upright position at normal room temperature (approximately 21 C) were tested for 60 min. with the cooling system operating at its maximum cooling capacity. Blood flows were recorded continuously using a computer data acquisition system with a sampling frequency of 250 Hz. Oral, right and left ear temperatures and cooling system parameters were logged manually every 5 min. Arm, leg, chest and rectal temperatures; heart rate; respiration; and an activity index were recorded continuously on a U.F.I., Inc. Biolog ambulatory monitor. No significant differences were found in either the oral or ear temperature responses to the two vests. However, the rectal and mean skin temperatures at the end of the cooling period were both significantly lower (P less than 0.05), approximately 0.2 and 1.9 C, respectively for the LET vest than for the Steele garment. These data show that different vest configurations may produce different thermal responses in healthy male subjects which should be considered in the use of these cooling garments.

  4. A clip-free eyeglasses-based wearable monitoring device for measuring photoplethysmograhic signals.

    PubMed

    Zheng, Yali; Leung, Billy; Sy, Stanley; Zhang, Yuanting; Poon, Carmen C Y

    2012-01-01

    An eyeglasses-based device has been developed in this work to acquire photoplethysmogram (PPG) from the nose bridge. This device is aimed to provide wearable physiological monitoring without uncomfortable clips frequently used in PPG measurement from finger and ear. Switching control is applied on the LED and photo detector for power saving. An experiment involving postural change and treadmill jogging among 10 healthy young subjects was carried out to evaluate the performance of the device. Electrocardiogram (ECG) and PPG from finger, ear and nose were simultaneously recorded, from which heart rate (HR) and pulse transit time (PTT) were calculated. The results show that PPG measured from nose and ear are more resistant to motion than signal from finger during exercise. In addition, the difference between PTT measured from ear and nose indicates that local vasomotor activities may exist on ear and/or nose channel, and suggests that PPG from different sites should be used for cuff-less PTT-based BP estimation. We conclude that this wearable device has great potential to be used in the healthcare management in the future.

  5. Comparison of Microbiological Flora in the External Auditory Canal of Normal Ear and an Ear with Acute Otitis Externa.

    PubMed

    Ghanpur, Asheesh Dora; Nayak, Dipak Ranjan; Chawla, Kiran; Shashidhar, V; Singh, Rohit

    2017-09-01

    Acute Otitis Externa (AOE) is also known as swimmer's ear. Investigations initiated during World War II firmly established the role of bacteria in the aetiology of Acute Otitis Externa. To culture the microbiological flora of the normal ear and compare it with the flora causing AOE and to know the role of normal ear canal flora and anaerobes in the aetiology. A prospective observational study was conducted on 64 patients clinically diagnosed with unilateral AOE. Ear swabs were taken from both the ears. Microbiological flora was studied considering diseased ear as test ear and the normal ear as the control. Aerobic and anaerobic cultures were done. Severity of the disease was assessed by subjective and objective scores. Effect of topical treatment with ichthammol glycerine pack was assessed after 48 hours and scores were calculated again. Patients with scores < 4 after pack removal were started on systemic antibiotics and were assessed after seven days of antibiotics course. Data was analysed using Paired t-test, Wilcoxon signed ranks test and Chi-square test. A p-value < 0.05 was considered significant. Pseudomonas aeruginosa (33%) was the most common bacteria cultured from the ear followed by Methicillin Resistant Staphylococcus aureus (MRSA) (18%). Patients with anaerobic organism in the test ear had severe symptoms and needed systemic antibiotic therapy. Most of the cases may respond to empirical antibiotic therapy. In cases with severe symptoms and the ones refractory to empirical treatment, a culture from the ear canal will not be a tax on the patient. This helps in giving a better understanding about the disease, causative organisms and helps in avoiding the use of inappropriate antibiotics that usually result in developing resistant strains of bacteria.

  6. Proposal of a Classification System for the Assessment and Treatment of Prominent Ear Deformity.

    PubMed

    Lee, Youngdae; Kim, Young Seok; Lee, Won Jai; Rha, Dong Kyun; Kim, Jiye

    2018-06-01

    Prominent ear is the most common external ear deformity. To comprehensively treat prominent ear deformity, adequate comprehension of its pathophysiology is crucial. In this article, we analyze cases of prominent ear and suggest a simple classification system and treatment algorithm according to pathophysiology. We retrospectively reviewed a total of 205 Northeast Asian patients' clinical data who underwent an operation for prominent ear deformity. Follow-up assessments were conducted 3, 6, and 12 months after surgery. Prominent ear deformities were classified by diagnostic checkpoints. Class I (simple prominent ear) includes prominent ear that developed with the absence of the antihelix without conchal hypertrophy. Class II (mixed-type prominent ear) is defined as having not only a flat antihelix, but also conchal excess. Class III (conchal-type prominent ear) has an enlarged conchal bowl with a well-developed antihelix. Among the three types of prominent ear, class I was most frequent (162 patients, 81.6%). Class II was observed in 28 patients (13.6%) and class III in 10 patients (4.8%). We used the scaphomastoid suture method for correction of antihelical effacement, the anterior approach conchal resection for correction of conchal hypertrophy, and Bauer's squid incision for lobule prominence. The complication rate was 9.2% including early hematoma, hypersensitivity, and suture extrusion. Unfavorable results occurred in 4% including partial recurrence, overcorrection, and undercorrection. To reduce unfavorable results and avoid recurrence, we propose the use of a classification and treatment algorithm in preoperative evaluation of prominent ear. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  7. A miniaturized laser-Doppler-system in the ear canal

    NASA Astrophysics Data System (ADS)

    Schmidt, T.; Gerhardt, U.; Kupper, C.; Manske, E.; Witte, H.

    2013-03-01

    Gathering vibrational data from the human middle ear is quite difficult. To this date the well-known acoustic probe is used to estimate audiometric parameters, e.g. otoacoustic emissions, wideband reflectance and the measurement of the stapedius reflex. An acoustic probe contains at least one microphone and one loudspeaker. The acoustic parameter determination of the ear canal is essential for the comparability of test-retest measurement situations. Compared to acoustic tubes, the ear canal wall cannot be described as a sound hard boundary. Sound energy is partly absorbed by the ear canal wall. In addition the ear canal features a complex geometric shape (Stinson and Lawton1). Those conditions are one reason for the inter individual variability in input impedance measurement data of the tympanic membrane. The method of Laser-Doppler-Vibrometry is well described in literature. Using this method, the surface velocity of vibrating bodies can be determined contact-free. Conventional Laser-Doppler-Systems (LDS) for auditory research are mounted on a surgical microscope. Assuming a free line of view to the ear drum, the handling of those laser-systems is complicated. We introduce the concept of a miniaturized vibrometer which is supposed to be applied directly in the ear canal for contact-free measurement of the tympanic membrane surface vibration. The proposed interferometer is based on a Fabry-Perot etalon with a DFB laser diode as light source. The fiber-based Fabry-Perot-interferometer is characterized by a reduced size, compared to e.g. Michelson-, or Mach-Zehnder-Systems. For the determination of the phase difference in the interferometer, a phase generated carrier was used. To fit the sensor head in the ear canal, the required shape of the probe was generated by means of the geometrical data of 70 ear molds. The suggested prototype is built up by a singlemode optical fiber with a GRIN-lens, acting as a fiber collimator. The probe has a diameter of 1.8 mm and a length of 5 mm.

  8. Exploring the Middle Pleistocene Lake Suguta Sr-isotope Stratigraphic record

    NASA Astrophysics Data System (ADS)

    Vonhof, Hubert; Junginger, Annett; Agmon, Nadav; Trauth, Martin

    2017-04-01

    Several studies into the Quaternary stratigraphic record of the Sr-isotope composition of paleolake Turkana in the East African Rift System (EARS) show how variation of climate left a signal of changing lacustrine Sr isotope values. This Sr isotope signal was captured in the lacustrine fossil record of the Turkana Basin, and can be a useful chemostratigraphic tool (e.g. Joordens et al., 2011; van der Lubbe et al., submitted). Such lacustrine Sr-isotope changes are believed to be paced by orbital-forced insolation cyclicity, and interpreted to be the result of changing contribution of run-off from different sub-catchments of lake Turkana, as climate change shifted regional rainfall patterns. Here, we present a first set of data from a middle Pleistocene stratigraphical sequence in the Suguta Valley, South of the Turkana Basin in the EARS. This sequence spans a couple of sedimentological cycles that potentially represent precession-forced lake level variation. In this setting, the Sr-isotope data do not vary in phase with these sedimentological cycles, but demonstrate a long trend of Sr isotope change. This may suggest that the catchment configuration of the Suguta Valley in the Mid Pleistocene was less suitable to record precession-forced hydroclimate change in Lacustrine Sr isotope ratios. This may have implications for the Turkana Basin Sr isotope record as well, because the two basins are believed to have been hydrologically connected in the Middle Pleistocene. references: 1)Joordens, J.C.A. et al., 2011. An astronomically-tuned climate framework for hominins in the Turkana Basin. Earth and Planetary Science Letters 307, 1-8. 2)van der Lubbe et al., submitted. Gradual or abrupt? Changes in water source of Lake Turkana (Kenya) during the African Humid Period inferred from Sr isotope ratios

  9. Transmission matrix analysis of the chinchilla middle ear

    PubMed Central

    Songer, Jocelyn E.; Rosowski, John J.

    2008-01-01

    Despite the common use of the chinchilla as an animal model in auditory research, a complete characterization of the chinchilla middle ear using transmission matrix analysis has not been performed. In this paper we describe measurements of middle-ear input admittance and stapes velocity in ears with the middle-ear cavity opened under three conditions: intact tympano-ossicular system and cochlea, after the cochlea has been drained, and after the stapes has been fixed. These measurements, made with stimulus frequencies of 100–8000 Hz, are used to define the transmission matrix parameters of the middle ear and to calculate the cochlear input impedance as well as the middle-ear output impedance. This transmission characterization of the chinchilla middle ear will be useful for modeling auditory sensitivity in the normal and pathological chinchilla ear. PMID:17672642

  10. Wearable Eating Habit Sensing System Using Internal Body Sound

    NASA Astrophysics Data System (ADS)

    Shuzo, Masaki; Komori, Shintaro; Takashima, Tomoko; Lopez, Guillaume; Tatsuta, Seiji; Yanagimoto, Shintaro; Warisawa, Shin'ichi; Delaunay, Jean-Jacques; Yamada, Ichiro

    Continuous monitoring of eating habits could be useful in preventing lifestyle diseases such as metabolic syndrome. Conventional methods consist of self-reporting and calculating mastication frequency based on the myoelectric potential of the masseter muscle. Both these methods are significant burdens for the user. We developed a non-invasive, wearable sensing system that can record eating habits over a long period of time in daily life. Our sensing system is composed of two bone conduction microphones placed in the ears that send internal body sound data to a portable IC recorder. Applying frequency spectrum analysis on the collected sound data, we could not only count the number of mastications during eating, but also accurately differentiate between eating, drinking, and speaking activities. This information can be used to evaluate the regularity of meals. Moreover, we were able to analyze sound features to classify the types of foods eaten by food texture.

  11. Tuberculous otitis media with mastoiditis and central nervous system involvement.

    PubMed

    Mongkolrattanothai, Kanokporn; Oram, Ronda; Redleaf, Miriam; Bova, Judy; Englund, Janet A

    2003-05-01

    Tuberculosis of the middle ear and mastoid is currently a rare disease in developed countries, but this disease still occurs and may cause serious consequences. We report a case of disseminated tuberculosis involving the middle ear, mastoid, lung and central nervous system. Tuberculosis should be considered in the differential diagnosis of chronic ear drainage, especially in young children.

  12. Acoustic feedback margin improvements in hearing instruments using a prototype DFS (digital feedback suppression) system.

    PubMed

    Dyrlund, O; Bisgaard, N

    1991-01-01

    The properties of a prototype DFS (digital feedback suppression) system have been investigated. 21 ears fitted with behind-the-ear (BTE) hearing instruments and hard acrylic ear-moulds and 4 ears fitted with vented in-the-ear (ITE) hearing instruments were selected for the investigation. Two ITE instruments with different venting were employed to one of the ears. Complex loop gain has been measured in an anechoic room, and from these measurements the improvements in acoustic feedback margin due to the DFS system have been determined. For the BTE group, median values of 13.1 and 10.0 dB of improvement were established for two sets of measurements introducing a 180 degrees phase shift in connection with the last set of measurements. For the ITE group, values from 9.8 to 16.1 dB and from 13.7 to 16.3 dB of improvement were observed for the normal and the 180 degrees phase shift conditions respectively. Beyond this the DFS system may improve the sound quality to some extent, because the amplitude distortion, caused by the external feedback signal, is almost completely eliminated.

  13. Multi-resolution analysis for ear recognition using wavelet features

    NASA Astrophysics Data System (ADS)

    Shoaib, M.; Basit, A.; Faye, I.

    2016-11-01

    Security is very important and in order to avoid any physical contact, identification of human when they are moving is necessary. Ear biometric is one of the methods by which a person can be identified using surveillance cameras. Various techniques have been proposed to increase the ear based recognition systems. In this work, a feature extraction method for human ear recognition based on wavelet transforms is proposed. The proposed features are approximation coefficients and specific details of level two after applying various types of wavelet transforms. Different wavelet transforms are applied to find the suitable wavelet. Minimum Euclidean distance is used as a matching criterion. Results achieved by the proposed method are promising and can be used in real time ear recognition system.

  14. [Advances in genetics of congenital malformation of external and middle ear].

    PubMed

    Wang, Dayong; Wang, Qiuju

    2013-05-01

    Congenital malformation of external and middle ear is a common disease in ENT department, and the incidence of this disease is second only to cleft lip and palate in the whole congenital malformations of the head and face. The external and middle ear malformations may occur separately, or as an important ear symptom of the systemic syndrome. We systematically review and analysis the genetic research progress of congenital malformation of external and middle ear, which would be helpful to understand the mechanism of external and middle ear development, and to provide clues for the further discovery of new virulence genes.

  15. Physiologic Responses Produced by Active and Passive Personal Cooling Vests

    NASA Technical Reports Server (NTRS)

    Ku, Yu-Tsuan E.; Lee, Hank C.; Montgomery, Leslie D.; Luna, Bernadette

    2000-01-01

    Personal thermoregulatory systems which provide chest cooling are used in the industrial and aerospace environments to alleviate thermal stress. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objectives of this study were to document and compare the subjects' response to three cooling vests in their recommended configurations. The Life Enhancement Tech (LET) lightweight active cooling vest with cap, the MicroClimate Systems Change of Phase garment (MCS), and the Steele Vest were each used to cool the chest regions of 12 male and 8 female Healthy subjects (21 to 69 yr.) in this study. The subjects, seated in an upright position at normal room temperature (approx. 22 C), were tested for 60 min. with one of the cooling garments. The LET active garment had an initial coolant fluid inlet temperature of 60 F, and was ramped down to 50 F. Oral, right and left ear canal temperatures were logged manually every 5 min. Arm, leg, chest and rectal temperatures; heart rate; and respiration were recorded continuously on a U.F.I., Inc. Biolog ambulatory monitor. For men, all three vests had similar, significant cooling effects. Decreases in the average rectal temperature, oral temperature, and ear canal temperatures were approximately 0.2 C, 0.2 C and 0.1 C, respectively. In contrast to the men, the female subjects wearing the MCS and Steel vests had similar cooling responses in which the core temperature remained elevated and oral and ear canal temperatures did not drop. The LET active garment cooled most of the female subjects in this study; rectal, oral and ear temperature decreased about 0.2 C, 0.3 C and 0.3 C, respectively. These results show that the garment configurations tested do not elicit a similar thermal response in all subjects. A gender difference is evident. The LET active garment configuration was most effective in decreasing temperatures of the female subjects; the MCS vest was least effective. For male subjects, the three vests appear to be more nearly equivalent. The active garment system under study included a cooling cap, which may account for some of the difference in response.

  16. Diplodiatoxin, chaetoglobosins, and diplonine associated with a field outbreak of Stenocarpella ear rot in Illinois.

    PubMed

    Rogers, Kristina D; Cannistra, Joseph C; Gloer, James B; Wicklow, Donald T

    2014-05-01

    Stenocarpella maydis causes a fungal dry-rot of maize ears and is associated with diplodiosis, a neuromycotoxicosis in cattle grazing harvested maize fields in southern Africa and Argentina. There have been no reports of Stenocarpella metabolites in maize crop residues. Chemical investigations of S. maydis-infected grain from ears exhibiting different levels of ear rot severity following a 2010 field outbreak of Stenocarpella ear rot in Illinois led to the detection of diplodiatoxin and chaetoglobosins M and O as major components in the ethyl acetate extracts by LC-MS. Following post-harvest moist incubation of the S. maydis-infected grain, the amounts of each compound increased (approx. tenfold) and chaetoglobosin K was detected as a dominant toxin. In separate (1)H NMR-based analyses, the neurotoxin diplonine was detected as a minor component in methanol extracts of S. maydis-infected grain as well as cultures of S. maydis isolates from Midwest corn. Proline betaine (=stachydrine) and glycine betaine were also detected in these extracts as major components. This constitutes the first report of chaetoglobosin M, chaetoglobosin O, proline betaine, or glycine betaine from S. maydis, and the first record of diplodiatoxin, diplonine, proline betaine, glycine betaine, or chaetoglobosins M, O, or K being associated with a natural field outreak of S. maydis ear rot.

  17. Eavesdropping on Character: Assessing Everyday Moral Behaviors.

    PubMed

    Bollich, Kathryn L; Doris, John M; Vazire, Simine; Raison, Charles L; Jackson, Joshua J; Mehl, Matthias R

    2016-04-01

    Despite decades of interest in moral character, comparatively little is known about moral behavior in everyday life. This paper reports a novel method for assessing everyday moral behaviors using the Electronically Activated Recorder (EAR)-a digital audio-recorder that intermittently samples snippets of ambient sounds from people's environments-and examines the stability of these moral behaviors. In three samples (combined N = 186), participants wore an EAR over one or two weekends. Audio files were coded for everyday moral behaviors (e.g., showing sympathy, gratitude) and morally-neutral comparison language behaviors (e.g., use of prepositions, articles). Results indicate that stable individual differences in moral behavior can be systematically observed in daily life, and that their stability is comparable to the stability of neutral language behaviors.

  18. Data mining of audiology patient records: factors influencing the choice of hearing aid type

    PubMed Central

    2012-01-01

    Background This paper describes the analysis of a database of over 180,000 patient records, collected from over 23,000 patients, by the hearing aid clinic at James Cook University Hospital in Middlesbrough, UK. These records consist of audiograms (graphs of the faintest sounds audible to the patient at six different pitches), categorical data (such as age, gender, diagnosis and hearing aid type) and brief free text notes made by the technicians. This data is mined to determine which factors contribute to the decision to fit a BTE (worn behind the ear) hearing aid as opposed to an ITE (worn in the ear) hearing aid. Methods From PCA (principal component analysis) four main audiogram types are determined, and are related to the type of hearing aid chosen. The effects of age, gender, diagnosis, masker, mould and individual audiogram frequencies are combined into a single model by means of logistic regression. Some significant keywords are also discovered in the free text fields by using the chi-squared (χ2) test, which can also be used in the model. The final model can act a decision support tool to help decide whether an individual patient should be offered a BTE or an ITE hearing aid. Results The final model was tested using 5-fold cross validation, and was able to replicate the decisions of audiologists whether to fit an ITE or a BTE hearing aid with precision in the range 0.79 to 0.87. Conclusions A decision support system was produced to predict the type of hearing aid which should be prescribed, with an explanation facility explaining how that decision was arrived at. This system should prove useful in providing a "second opinion" for audiologists. PMID:22595091

  19. Three-Dimensional Analysis of the Ear Morphology.

    PubMed

    Modabber, Ali; Galster, Helmut; Peters, Florian; Möhlhenrich, Stephan Christian; Kniha, Kristian; Knobe, Matthias; Hölzle, Frank; Ghassemi, Alireza

    2018-06-01

    For surgical treatment of the face, detailed surgical planning is necessary to avoid later unaesthetic results. Most of the studies in the literature concentrate on the ears' anatomy during childhood and adolescence. Nearly no study evaluates the anatomy of ears of people aged 50 or older. It was our aim to measure and evaluate the ear's anatomy in Caucasians between the ages of 21 and 65. Three-dimensional scans of 240 volunteers were taken. The subjects were divided into groups of males and females and each of them into three groups by age (21-35, 36-50, 51-65). Landmarks were placed in these scans. Distances, relations and angles between them were recorded. The distance between the subaurale and superaurale significantly increases (p < 0.001) during the aging process in males and females. Also, the width of the ear, measured between the preaurale and postaurale, significantly increased (p = 0.007) with advancing age. When the length of the ear is divided into four parts by anatomical landmarks, it extended the most in the lower quadrant with increasing subject age. The ear of Caucasians does not stop changing its shape during adulthood. Even after the body has stopped growing, the ear still does. With the measured values in this study, it should be possible for the surgeon to plan the operation in advance and achieve satisfactory aesthetic outcomes. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  20. Three years audit of the emergency patients in the department of ENT of a rural medical college.

    PubMed

    Barman, Debasis; Maridal, Satadal; Goswami, Saileswar; Hembram, Rabi

    2012-06-01

    Surgical audit is a systematic, critical analysis of the quality of surgical care provided, with the aims of improving quality of care, continuing education for surgeons, and guiding appropriate use of health resources. Emergency service is an integral part of any discipline of clinical medicine and it is considered as an indicator of quality of healthcare system. A three years record based, retrospective, cross-sectional study was carried out in the department of ear, nose and throat (ENT) of Midnapore Medical College, Paschim Medinipur,West Bengal to identify the total attendance of various emergency patients, diagnosis made thereafter, the mode of interference and outcome and the potential problems in the quality of care provided to the community. A total of 9051 patients had been admitted/attended in the ENT emergency from January 2008 to December 2010 who were included in this audit. Detailed statistical analysis of the data showed male: female (2.38:1) with the peak in the first decade of life. Majority of the patients were from Medinipur sadar (58.43%). The total otological cases were maximum (42.41%) in comparison to nose (28.98%) and throat (28.60%). The most common ear emergencies were earache due to impacted wax, acute suppurative otitis media, foreign body ear and the trauma/injury. Chronic suppurative otitis media with complications were the least. Amongst the sinonasal emergency, the most common aetiology was the epistaxis and foreign body nose in children. The different types of foreign body impaction in the throat and the inflammatory condition of throat or the inspiratory stridor due to upper airway obstruction were the main emergency situation recorded. Some cases were fatal. The overall mortality was 0.44%.

  1. Assessment of Cognitive Processing by Multiple Sclerosis Patients Using Electroencephalographic Energy Density Analysis

    NASA Technical Reports Server (NTRS)

    Montgomery, Leslie D.; Ku, Yu-Tsuan E.; Luna, Bernadette; Montgomery, Richard W.; Kliss, Mark (Technical Monitor)

    1997-01-01

    Recent neuropsychological studies demonstrate that cognitive dysfunction is a common symptom in patients with multiple sclerosis. In many cases the presence of cognitive impairment affects the patient's daily activities to a greater extent than would be found due to their physical disability alone. Cognitive dysfunction can have a significant impact on the quality of life of both the patient and that of their primary caregiver. Two cognitively impaired male MS patients were given a visual discrimination task before and after a one hour cooling period. The subjects were presented a series of either red or blue circles or triangles. One of these combinations, or one fourth of the stimuli, was designated as the "target" presentation. EEG was recorded from 20 scalp electrodes using a Tracor Northern 7500 EEG/ERP system. Oral and ear temperatures were obtained and recorded manually every five minutes during the one hour cooling period. The EEG ERP signatures from each series of stimuli were analyzed in the energy density domain to determine the locus of neural activity at each EEG sampling time. The first subject's ear temperature did not decrease during the cooling period. It was actually elevated approximately 0.05C by the end of the cooling period compared to his mean of control period value. In turn, Subject One's discrimination performance and cortical energy remained essentially the same after body cooling. In contrast, Subject Two's ear temperature decreased approx. 0.8C during his cooling period. Subject Two's ERROR score decreased from 12 during the precooling control period to 2 after cooling. His ENERGY value increased approximately 300%, from a precooling value of approximately 200 to a postcooling value of nearly 600.

  2. Noninvasive in vivo optical coherence tomography tracking of chronic otitis media in pediatric subjects after surgical intervention

    NASA Astrophysics Data System (ADS)

    Monroy, Guillermo L.; Pande, Paritosh; Nolan, Ryan M.; Shelton, Ryan L.; Porter, Ryan G.; Novak, Michael A.; Spillman, Darold R.; Chaney, Eric J.; McCormick, Daniel T.; Boppart, Stephen A.

    2017-12-01

    In an institutional review board-approved study, 25 pediatric subjects diagnosed with chronic or recurrent otitis media were observed over a period of six months with optical coherence tomography (OCT). Subjects were followed throughout their treatment at the initial patient evaluation and preoperative consultation, surgery (intraoperative imaging), and postoperative follow-up, followed by an additional six months of records-based observation. At each time point, the tympanic membrane (at the light reflex region) and directly adjacent middle-ear cavity were observed in vivo with a handheld OCT probe and portable system. Imaging results were compared with clinical outcomes to correlate the clearance of symptoms in relation to changes in the image-based features of infection. OCT images of most all participants showed the presence of additional infection-related biofilm structures during their initial consultation visit and similarly for subjects imaged intraoperatively before myringotomy. Subjects with successful treatment (no recurrence of infectious symptoms) had no additional structures visible in OCT images during the postoperative visit. OCT image findings suggest surgical intervention consisting of myringotomy and tympanostomy tube placement provides a means to clear the middle ear of infection-related components, including middle-ear fluid and biofilms. Furthermore, OCT was demonstrated as a rapid diagnostic tool to prospectively monitor patients in both outpatient and surgical settings.

  3. A self-teaching image processing and voice-recognition-based, intelligent and interactive system to educate visually impaired children

    NASA Astrophysics Data System (ADS)

    Iqbal, Asim; Farooq, Umar; Mahmood, Hassan; Asad, Muhammad Usman; Khan, Akrama; Atiq, Hafiz Muhammad

    2010-02-01

    A self teaching image processing and voice recognition based system is developed to educate visually impaired children, chiefly in their primary education. System comprises of a computer, a vision camera, an ear speaker and a microphone. Camera, attached with the computer system is mounted on the ceiling opposite (on the required angle) to the desk on which the book is placed. Sample images and voices in the form of instructions and commands of English, Urdu alphabets, Numeric Digits, Operators and Shapes are already stored in the database. A blind child first reads the embossed character (object) with the help of fingers than he speaks the answer, name of the character, shape etc into the microphone. With the voice command of a blind child received by the microphone, image is taken by the camera which is processed by MATLAB® program developed with the help of Image Acquisition and Image processing toolbox and generates a response or required set of instructions to child via ear speaker, resulting in self education of a visually impaired child. Speech recognition program is also developed in MATLAB® with the help of Data Acquisition and Signal Processing toolbox which records and process the command of the blind child.

  4. Evaluation of intratympanic formulations for inner ear delivery: methodology and sustained release formulation testing

    PubMed Central

    Liu, Hongzhuo; Feng, Liang; Tolia, Gaurav; Liddell, Mark R.; Hao, Jinsong; Li, S. Kevin

    2013-01-01

    A convenient and efficient in vitro diffusion cell method to evaluate formulations for inner ear delivery via the intratympanic route is currently not available. The existing in vitro diffusion cell systems commonly used to evaluate drug formulations do not resemble the physical dimensions of the middle ear and round window membrane. The objectives of this study were to examine a modified in vitro diffusion cell system of a small diffusion area for studying sustained release formulations in inner ear drug delivery and to identify a formulation for sustained drug delivery to the inner ear. Four formulations and a control were examined in this study using cidofovir as the model drug. Drug release from the formulations in the modified diffusion cell system was slower than that in the conventional diffusion cell system due to the decrease in the diffusion surface area of the modified diffusion cell system. The modified diffusion cell system was able to show different drug release behaviors among the formulations and allowed formulation evaluation better than the conventional diffusion cell system. Among the formulations investigated, poly(lactic-co-glycolic acid)–poly(ethylene glycol)–poly(lactic-co-glycolic acid) triblock copolymer systems provided the longest sustained drug delivery, probably due to their rigid gel structures and/or polymer-to-cidofovir interactions. PMID:23631539

  5. Analysis of Eustachian Tube Dysfunction by Dynamic Slow Motion Video Endoscopy and Eustachian Tube Dysfunction Questionnaire in Chronic Otitis Media

    PubMed Central

    Han, Won Gue; Yoo, Jun; Rah, Yoon Chan; Chang, Jiwon; Im, Gi Jung; Song, Jae-Jun; Chae, Sung Won; Jung, Hak Hyun; Choi, June

    2017-01-01

    Objectives Eustachian tube dysfunction has been associated with most cases of middle-ear disease. We aimed to assess the effectiveness of dynamic slow motion video endoscopy (DSVE) as a test of eustachian tube dysfunction. Furthermore, we assessed the correlation of the test with the Valsalva maneuver, the seven-item Eustachian Tube Dysfunction Questionnaire (ETDQ-7), and intraoperative findings of the eustachian tube. Methods We retrospectively reviewed medical records from April to September 2014 to identify patients who were diagnosed with chronic otitis media (COM) at Korea University Ansan Hospital. They all underwent surgery because of COM without cholesteatoma and were assessed via the DSVE and ETDQ-7 to determine eustachian tube function. Results We reviewed 46 COM patients and examined 46 ears with COM and 46 ears on the contralateral side to COM that were thought to be normal. The mean DSVE grade in COM ears was 1.57±0.96, while the mean DSVE grade in contralateral ears was 1.15±0.94. The difference in DSVE between COM ears and normal ears was statistically significant (P=0.006). In the ETDQ-7, a higher score was related to intraoperative obstruction of the eustachian tube (P=0.012). Conclusion DSVE and ETDQ-7 can provide information regarding preoperative status of eustachian tube dysfunction by measuring dynamic structural changes of the eustachian tube in combination with other diagnostic tests. PMID:28602066

  6. Nonsurgical correction of congenital ear abnormalities in the newborn: Case series.

    PubMed

    Smith, Wg; Toye, Jw; Reid, A; Smith, Rw

    2005-07-01

    To determine whether a simple, nonsurgical treatment for congenital ear abnormalities (lop-ear, Stahl's ear, protruding ear, cryptotia) improved the appearance of ear abnormalities in newborns at six weeks of age. This is a descriptive case series. All newborns with identified abnormalities were referred by their family physician to one paediatrician (WGS) in a small level 2 perinatal centre. The ears were waxed and taped in a standard manner within 10 days of birth. Pictures were taken before taping and at the end of taping (one month). All patients and pictures were assessed by one plastic surgeon (JWT) at six weeks of age and scored using a standard scoring system. A telephone survey of the nontreatment group was conducted. The total number of ears assessed was 90. Of this total, 69 ears were taped and fully evaluated in the study (77%). The refusal rate was 23%. In the treatment group, 59% had lop-ear, 19% had Stahl's ear, 17% had protruding ear and 3% had cryptotia. Overall correction (excellent/improved) for the treatment group was 90% (100% for lop-ear, 100% for Stahl's ear, 67% for protruding ear and 0% for cryptotia). In the nontreatment (refusal) group, 67% of the ears failed to correct spontaneously. No complications were recognized by the authors or parents by six weeks. The percentage of newborns in one year in the perinatal centre with recognized ear abnormalities was 6% (90 of 1600). A simple, nonsurgical treatment in a Caucasian population appeared to be very effective in correcting congenital ear abnormalities with no complications and high patient/parent satisfaction.

  7. Simulations and Measurements of Human Middle Ear Vibrations Using Multi-Body Systems and Laser-Doppler Vibrometry with the Floating Mass Transducer.

    PubMed

    Böhnke, Frank; Bretan, Theodor; Lehner, Stefan; Strenger, Tobias

    2013-10-22

    The transfer characteristic of the human middle ear with an applied middle ear implant (floating mass transducer) is examined computationally with a Multi-body System approach and compared with experimental results. For this purpose, the geometry of the middle ear was reconstructed from μ-computer tomography slice data and prepared for a Multi-body System simulation. The transfer function of the floating mass transducer, which is the ratio of the input voltage and the generated force, is derived based on a physical context. The numerical results obtained with the Multi-body System approach are compared with experimental results by Laser Doppler measurements of the stapes footplate velocities of five different specimens. Although slightly differing anatomical structures were used for the calculation and the measurement, a high correspondence with respect to the course of stapes footplate displacement along the frequency was found. Notably, a notch at frequencies just below 1 kHz occurred. Additionally, phase courses of stapes footplate displacements were determined computationally if possible and compared with experimental results. The examinations were undertaken to quantify stapes footplate displacements in the clinical practice of middle ear implants and, also, to develop fitting strategies on a physical basis for hearing impaired patients aided with middle ear implants.

  8. Objective analysis of ambisonics for hearing aid applications: Effect of listener's head, room reverberation, and directional microphones.

    PubMed

    Oreinos, Chris; Buchholz, Jörg M

    2015-06-01

    Recently, an increased interest has been demonstrated in evaluating hearing aids (HAs) inside controlled, but at the same time, realistic sound environments. A promising candidate that employs loudspeakers for realizing such sound environments is the listener-centered method of higher-order ambisonics (HOA). Although the accuracy of HOA has been widely studied, it remains unclear to what extent the results can be generalized when (1) a listener wearing HAs that may feature multi-microphone directional algorithms is considered inside the reconstructed sound field and (2) reverberant scenes are recorded and reconstructed. For the purpose of objectively validating HOA for listening tests involving HAs, a framework was developed to simulate the entire path of sounds presented in a modeled room, recorded by a HOA microphone array, decoded to a loudspeaker array, and finally received at the ears and HA microphones of a dummy listener fitted with HAs. Reproduction errors at the ear signals and at the output of a cardioid HA microphone were analyzed for different anechoic and reverberant scenes. It was found that the diffuse reverberation reduces the considered time-averaged HOA reconstruction errors which, depending on the considered application, suggests that reverberation can increase the usable frequency range of a HOA system.

  9. 76 FR 62164 - VASRD Improvement Forum-Updating Disability Criteria for the Respiratory System, Cardiovascular...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-06

    ... Respiratory System, Cardiovascular System, Hearing Impairment, and Ear, Nose and Throat Diseases AGENCY... System, Cardiovascular System, Hearing Impairment, and Ear, Nose and Throat Diseases. The purpose of this...) the Cardiovascular System (38 CFR 4.100-4.104), (3) the Impairment of Auditory Acuity (38 CFR 4.85 and...

  10. Relative size of auditory pathways in symmetrically and asymmetrically eared owls.

    PubMed

    Gutiérrez-Ibáñez, Cristián; Iwaniuk, Andrew N; Wylie, Douglas R

    2011-01-01

    Owls are highly efficient predators with a specialized auditory system designed to aid in the localization of prey. One of the most unique anatomical features of the owl auditory system is the evolution of vertically asymmetrical ears in some species, which improves their ability to localize the elevational component of a sound stimulus. In the asymmetrically eared barn owl, interaural time differences (ITD) are used to localize sounds in azimuth, whereas interaural level differences (ILD) are used to localize sounds in elevation. These two features are processed independently in two separate neural pathways that converge in the external nucleus of the inferior colliculus to form an auditory map of space. Here, we present a comparison of the relative volume of 11 auditory nuclei in both the ITD and the ILD pathways of 8 species of symmetrically and asymmetrically eared owls in order to investigate evolutionary changes in the auditory pathways in relation to ear asymmetry. Overall, our results indicate that asymmetrically eared owls have much larger auditory nuclei than owls with symmetrical ears. In asymmetrically eared owls we found that both the ITD and ILD pathways are equally enlarged, and other auditory nuclei, not directly involved in binaural comparisons, are also enlarged. We suggest that the hypertrophy of auditory nuclei in asymmetrically eared owls likely reflects both an improved ability to precisely locate sounds in space and an expansion of the hearing range. Additionally, our results suggest that the hypertrophy of nuclei that compute space may have preceded that of the expansion of the hearing range and evolutionary changes in the size of the auditory system occurred independently of phylogeny. Copyright © 2011 S. Karger AG, Basel.

  11. Comparison of Boric Acid and Combination Drug of Polymyxin, Neomycin and Hydrocortisone (polymyxin NH) in the Treatment of Acute Otitis Externa.

    PubMed

    Amani, Soroush; Moeini, Mohammad

    2016-07-01

    Acute otitis externa is an inflammation of the external auditory canal known as "swimmer's ear". Direct costs including medical treatment, painkillers, antibiotics, steroids or both and indirect costs are also remarkable. The aim of this study was to compare the effect of boric acid and polymyxin, neomycin and hydrocortisone composition in the treatment of acute otitis externa. This randomized clinical trial was carried out on 80 patients aged more than 17-year-old who were referred to Kashani hospital clinic with a diagnosis of acute otitis externa by otolaryngologist. The patients were randomly allocated to two groups (A: Boric acid and B: polymyxin NH ear drops) and Painkiller was prescribed and administered orally for all patients and in the presence of fever, cellulitis around the ears and neck adenopathy, broad-spectrum systemic antibiotics were used besides topical treatment. Symptoms of patients who were evaluated by a physician includes pain, discharge from the ear, swelling of the ear canal, auricle swelling, tenderness, and ear itching. In addition, pain was evaluated in patients and was recorded by Macgill Pain Questionnaire, in the first, third, seventh and tenth days. Results showed that itching on third day (p=0.007) and swelling of the ear canal in the examination of the third day (p=0.006) and the seventh day (p=0.001) in the polymyxin NH group was more than those of boric acid group. Overall mean pain based on McGill questionnaire was 11.10±1.49 in boric acid group in the examination on the first day and was 4.05±0.22 in the examination on the tenth day and in the polymyxin NH group, it was 10.9±0.99 on the first day and 4.20±0.40 on the tenth day. In both groups, pain relief was the same and there was no significant difference between two groups (p=0.075). The findings of this study showed slight differences in the effectiveness of the boric acid drug and combination of polymyxin, neomycin and hydrocortisone in the treatment of patients with acute otitis externa that is of clinical significance.

  12. Comparison of Boric Acid and Combination Drug of Polymyxin, Neomycin and Hydrocortisone (polymyxin NH) in the Treatment of Acute Otitis Externa

    PubMed Central

    Moeini, Mohammad

    2016-01-01

    Introduction Acute otitis externa is an inflammation of the external auditory canal known as "swimmer’s ear". Direct costs including medical treatment, painkillers, antibiotics, steroids or both and indirect costs are also remarkable. Aim The aim of this study was to compare the effect of boric acid and polymyxin, neomycin and hydrocortisone composition in the treatment of acute otitis externa. Materials and Methods This randomized clinical trial was carried out on 80 patients aged more than 17-year-old who were referred to Kashani hospital clinic with a diagnosis of acute otitis externa by otolaryngologist. The patients were randomly allocated to two groups (A: Boric acid and B: polymyxin NH ear drops) and Painkiller was prescribed and administered orally for all patients and in the presence of fever, cellulitis around the ears and neck adenopathy, broad-spectrum systemic antibiotics were used besides topical treatment. Symptoms of patients who were evaluated by a physician includes pain, discharge from the ear, swelling of the ear canal, auricle swelling, tenderness, and ear itching. In addition, pain was evaluated in patients and was recorded by Macgill Pain Questionnaire, in the first, third, seventh and tenth days. Results Results showed that itching on third day (p=0.007) and swelling of the ear canal in the examination of the third day (p=0.006) and the seventh day (p=0.001) in the polymyxin NH group was more than those of boric acid group. Overall mean pain based on McGill questionnaire was 11.10±1.49 in boric acid group in the examination on the first day and was 4.05±0.22 in the examination on the tenth day and in the polymyxin NH group, it was 10.9±0.99 on the first day and 4.20±0.40 on the tenth day. In both groups, pain relief was the same and there was no significant difference between two groups (p=0.075). Conclusion The findings of this study showed slight differences in the effectiveness of the boric acid drug and combination of polymyxin, neomycin and hydrocortisone in the treatment of patients with acute otitis externa that is of clinical significance. PMID:27630871

  13. Molecular detection of the causative agent of white-nose syndrome on Rafinesque's big-eared bats (Corynorhinus rafinesquii) and two species of migratory bats in the southeastern USA.

    PubMed

    Bernard, Riley F; Foster, Jeffrey T; Willcox, Emma V; Parise, Katy L; McCracken, Gary F

    2015-04-01

    Pseudogymnoascus destructans, the causal agent of white-nose syndrome (WNS), is responsible for widespread mortality of hibernating bats across eastern North America. To document P. destructans exposure and infections on bats active during winter in the southeastern US, we collected epidermal swabs from bats captured during winters 2012-13 and 2013-14 in mist nets set outside of hibernacula in Tennessee. Epidermal swab samples were collected from eight Rafinesque's big-eared bats (Corynorhinus rafinesquii), six eastern red bats (Lasiurus borealis), and three silver-hair bats (Lasionycteris noctivagans). Using real-time PCR methods, we identified DNA sequences of P. destructans from skin swabs of two Rafinesque's big-eared bats, two eastern red bats, and one silver-haired bat. This is the first detection of the WNS fungus on Rafinesque's big-eared bats and eastern red bats and the second record of the presence of the fungus on silver-haired bats.

  14. Canal wall reconstruction and preservation in the surgical management of cholesteatoma in children with Down's syndrome.

    PubMed

    Nash, Robert; Possamai, Victoria; Maskell, Scott; Bailey, Martin; Albert, David

    2014-10-01

    Down's syndrome is associated with poor Eustachian tube function, and an increased incidence of cholesteatoma. The only previously published case series suggests that 'canal wall preserving' procedures are only rarely suitable for the management of cholesteatoma in this population. We conducted a retrospective review of the hospital's clinical records database to identify patients with Down's syndrome and cholesteatoma. These patients' notes were then reviewed. We identified nine patients with Down's syndrome who had undergone surgical management of cholesteatoma over a twelve year period. Three patients had bilateral disease, meaning twelve ears were treated. Seven ears were initially treated with 'canal wall down' procedures. Four out of five of the remaining ears were successfully treated using 'canal wall preservation' or 'canal wall reconstruction', with one ear requiring subsequent conversion to a 'canal wall down' approach. Canal wall preservation/reconstruction is feasible in patients with Down's syndrome, even when cholesteatoma extends into the mastoid. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  15. Deep features for efficient multi-biometric recognition with face and ear images

    NASA Astrophysics Data System (ADS)

    Omara, Ibrahim; Xiao, Gang; Amrani, Moussa; Yan, Zifei; Zuo, Wangmeng

    2017-07-01

    Recently, multimodal biometric systems have received considerable research interest in many applications especially in the fields of security. Multimodal systems can increase the resistance to spoof attacks, provide more details and flexibility, and lead to better performance and lower error rate. In this paper, we present a multimodal biometric system based on face and ear, and propose how to exploit the extracted deep features from Convolutional Neural Networks (CNNs) on the face and ear images to introduce more powerful discriminative features and robust representation ability for them. First, the deep features for face and ear images are extracted based on VGG-M Net. Second, the extracted deep features are fused by using a traditional concatenation and a Discriminant Correlation Analysis (DCA) algorithm. Third, multiclass support vector machine is adopted for matching and classification. The experimental results show that the proposed multimodal system based on deep features is efficient and achieves a promising recognition rate up to 100 % by using face and ear. In addition, the results indicate that the fusion based on DCA is superior to traditional fusion.

  16. Feasibility and acceptability of training community health workers in ear and hearing care in Malawi: a cluster randomised controlled trial.

    PubMed

    Mulwafu, Wakisa; Kuper, Hannah; Viste, Asgaut; Goplen, Frederik K

    2017-10-11

    To assess the feasibility and acceptability of training community health workers (CHWs) in ear and hearing care, and their ability to identify patients with ear and hearing disorders. Cluster randomised controlled trial (RCT). Health centres in Thyolo district, Malawi. Ten health centres participated, 5 intervention (29 CHWs) and 5 control (28 CHWs). Intervention CHWs received 3 days of training in primary ear and hearing care, while among control CHWs, training was delayed for 6 months. Both groups were given a pretest that assessed knowledge about ear and hearing care, only the intervention group was given the posttest on the third day of training. The intervention group was given 1 month to identify patients with ear and hearing disorders in their communities, and these people were screened for hearing disorders by ear, nose and throat clinical specialists. Primary outcome measure was improvement in knowledge of ear and hearing care among CHWs after the training. Secondary outcome measures were number of patients with ear or hearing disorders identified by CHWs and number recorded at health centres during routine activities, and the perceived feasibility and acceptability of the intervention. The average overall correct answers increased from 55% to 68% (95% CI 65 to 71) in the intervention group (p<0.001). A total of 1739 patients with potential ear and hearing disorders were identified by CHWs and 860 patients attended the screening camps, of whom 400 had hearing loss (73 patients determined through bilateral fail on otoacoustic emissions, 327 patients through audiometry). Where cause could be determined, the most common cause of ear and hearing disorders was chronic suppurative otitis media followed by impacted wax. The intervention was perceived as feasible and acceptable to implement. Training was effective in improving the knowledge of CHW in ear and hearing care in Malawi and allowing them to identify patients with ear and hearing disorders. This intervention could be scaled up to other CHWs in low-income and middle-income countries. Pan African Clinical Trial Registry (201705002285194); Results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  17. Reconstruction of Moderately Constricted Ears by Combining V-Y Advancement of Helical Root, Conchal Cartilage Graft, and Mastoid Hitch.

    PubMed

    Elshahat, Ahmed; Lashin, Riham

    2016-01-01

    Despite the multitude of corrective procedures described in the literature, adequate surgical correction of the congenital constricted ear remains a challenge. The maintenance of the shape and size of the reconstructed upper neohelix poses a particular problem. In the present study, a total of 12 cases of reconstruction were undertaken. All of them were moderate (type IIA Tanzer classification) deformities. A combined procedure was adopted using a V-Y advancement of the helical root, cartilage scoring, and cartilage grafting from the contralateral concha to reconstruct the upper helix. A mastoid hitch was used as an adjunct to these procedures to maintain helical elevation and prevent recurrence. Mean follow-up period was 6 months. RESULTS were excellent (n = 7), good (n = 4), and fair (n = 1). Paired t test showed a significant increase in the height of the constricted ear postoperatively (P < .001) and a nonsignificant difference between the height of the constricted and contralateral ears postoperatively (P > .05). Apart from dislodgment of the mastoid hitch suture in 1 patient, no complications were recorded. This combined technique is useful in correcting moderately constricted ear deformities.

  18. Correction of lower lid retraction combined with entropion using an ear cartilage graft in the anophthalmic socket.

    PubMed

    Moon, Jun Woong; Choung, Ho Kyung; Khwarg, Sang In

    2005-09-01

    To investigate the surgical results of an ear cartilage graft and supplemental procedures for correcting lower lid retraction combined with entropion in anophthalmic patients. We reviewed retrospectively the medical records of 7 anophthalmic patients with lower lid retraction and entropion, who received a posterior lamellar ear cartilage graft and one or both of lateral tarsal strip or eyelash-everting procedure between March 1998 and March 2003. Preoperative and postoperative lid and socket statuses were also investigated. Ear cartilage grafts were performed in all 7 patients, lateral tarsal strips in 6, and eyelash-everting procedures in 5. Postoperative follow-up durations ranged from 4 to 28 months (average 12.6 months). Retractions were corrected during follow-up in all patients. There were no cases of entropion immediately after surgery. However, the eyelashes of the lower lid returned to an upright position in 4 patients, but not so severe as to touch the ocular prosthesis, and thus did not require surgical correction during follow up. Lower lid retraction combined with entropion in anophthalmic patients can be corrected effectively using an ear cartilage graft with selective, supplemental procedures.

  19. Predicting Lameness in Sheep Activity Using Tri-Axial Acceleration Signals

    PubMed Central

    Barwick, Jamie; Lamb, David; Dobos, Robin; Schneider, Derek; Welch, Mitchell; Trotter, Mark

    2018-01-01

    Simple Summary Monitoring livestock farmed under extensive conditions is challenging and this is particularly difficult when observing animal behaviour at an individual level. Lameness is a disease symptom that has traditionally relied on visual inspection to detect those animals with an abnormal walking pattern. More recently, accelerometer sensors have been used in other livestock industries to detect lame animals. These devices are able to record changes in activity intensity, allowing us to differentiate between a grazing, walking, and resting animal. Using these on-animal sensors, grazing, standing, walking, and lame walking were accurately detected from an ear attached sensor. With further development, this classification algorithm could be linked with an automatic livestock monitoring system to provide real time information on individual health status, something that is practically not possible under current extensive livestock production systems. Abstract Lameness is a clinical symptom associated with a number of sheep diseases around the world, having adverse effects on weight gain, fertility, and lamb birth weight, and increasing the risk of secondary diseases. Current methods to identify lame animals rely on labour intensive visual inspection. The aim of this current study was to determine the ability of a collar, leg, and ear attached tri-axial accelerometer to discriminate between sound and lame gait movement in sheep. Data were separated into 10 s mutually exclusive behaviour epochs and subjected to Quadratic Discriminant Analysis (QDA). Initial analysis showed the high misclassification of lame grazing events with sound grazing and standing from all deployment modes. The final classification model, which included lame walking and all sound activity classes, yielded a prediction accuracy for lame locomotion of 82%, 35%, and 87% for the ear, collar, and leg deployments, respectively. Misclassification of sound walking with lame walking within the leg accelerometer dataset highlights the superiority of an ear mode of attachment for the classification of lame gait characteristics based on time series accelerometer data. PMID:29324700

  20. Can you hear me now? Understanding vertebrate middle ear development

    PubMed Central

    Chapman, Susan Caroline

    2010-01-01

    The middle ear is a composite organ formed from all three germ layers and the neural crest. It provides the link between the outside world and the inner ear, where sound is transduced and routed to the brain for processing. Extensive classical and modern studies have described the complex morphology and origin of the middle ear. Non-mammalian vertebrates have a single ossicle, the columella. Mammals have three functionally equivalent ossicles, designated the malleus, incus and stapes. In this review, I focus on the role of genes known to function in the middle ear. Genetic studies are beginning to unravel the induction and patterning of the multiple middle ear elements including the tympanum, skeletal elements, the air-filled cavity, and the insertion point into the inner ear oval window. Future studies that elucidate the integrated spatio-temporal signaling mechanisms required to pattern the middle ear organ system are needed. The longer-term translational benefits of understanding normal and abnormal ear development will have a direct impact on human health outcomes. PMID:21196256

  1. A longitudinal study of hearing and middle ear status of individuals with cleft palate with and without additional malformations/syndromes.

    PubMed

    Flynn, Traci; Persson, Christina; Moller, Claes; Lohmander, Anette; Magnusson, Lennart

    2014-09-01

    Objective : To describe and compare the middle ear status and hearing sensitivity in adolescence with isolated cleft palate plus additional malformations and/or syndromes with those with only an isolated cleft palate. Design : Retrospective and longitudinal. Two groups of individuals with isolated cleft palate were compared. Participants : A cohort of individuals born over 4 years in the western region of Sweden. The cohort was divided into one group with isolated cleft palate (n = 31; ICP) and one group with isolated cleft palate plus additional malformations and/or syndromes (n = 37; ICP+). Methods : Middle ear status and hearing thresholds were collected from the medical records at 7, 10, 13, and 16 years of age, examined, and compared within and between groups over time. Results : The ICP+ group demonstrated a significantly higher prevalence of abnormal middle ear status and elevated hearing thresholds as compared with the ICP group. As the individuals aged, the prevalence of abnormal middle ear status decreased. The hearing levels in both groups decreased in the low to middle frequencies as individuals aged; however, the hearing in the high frequencies did not. Conclusions : Individuals with cleft palate need to be followed routinely for middle ear status and hearing thresholds to ensure optimal audiological rehabilitation, with particular attention to those with additional malformations and/or syndromes.

  2. Does ASA classification impact success rates of endovascular aneurysm repairs?

    PubMed

    Conners, Michael S; Tonnessen, Britt H; Sternbergh, W Charles; Carter, Glen; Yoselevitz, Moises; Money, Samuel R

    2002-09-01

    The purpose of this study was to evaluate the technical success, clinical success, postoperative complication rate, need for a secondary procedure, and mortality rate with endovascular aneurysm repair (EAR), based on the physical status classification scheme advocated by the American Society of Anesthesiologists (ASA). At a single institution 167 patients underwent attempted EAR. Query of a prospectively maintained database supplemented with a retrospective review of medical records was used to gather statistics pertaining to patient demographics and outcome. In patients selected for EAR on the basis of acceptable anatomy, technical and clinical success rates were not significantly different among the different ASA classifications. Importantly, postoperative complication and 30-day mortality rates do not appear to significantly differ among the different ASA classifications in this patient population.

  3. Evidence for a Right-Ear Advantage in Newborn Hearing Screening Results.

    PubMed

    Ari-Even Roth, Daphne; Hildesheimer, Minka; Roziner, Ilan; Henkin, Yael

    2016-12-06

    The aim of the present study was to investigate the effect of ear asymmetry, order of testing, and gender on transient-evoked otoacoustic emission (TEOAE) pass rates and response levels in newborn hearing screening. The screening results of 879 newborns, of whom 387 (study group) passed screening successfully in only one ear in the first TEOAE screening, but passed screening successfully in both ears thereafter, and 492 (control group) who passed screening successfully in both ears in the first TEOAE, were retrospectively examined for pass rates and TEOAE characteristics. Results indicated a right-ear advantage, as manifested by significantly higher pass rates in the right ear (61% and 39% for right and left ears, respectively) in the study group, and in 1.75 dB greater TEOAE response amplitudes in the control group. The right-ear advantage was enhanced when the first tested ear was the right ear (76%). When the left ear was tested first, pass rates were comparable in both ears. The right-ear advantage in pass rates was similar in females versus males, but manifested in 1.5 dB higher response amplitudes in females compared with males, regardless of the tested ear and order of testing in both study and control groups. The study provides further evidence for the functional lateralization of the auditory system at the cochlear level already apparent soon after birth in both males and females. While order of testing plays a significant role in the asymmetry in pass rates, the innate right-ear advantage seems to be a more dominant contributor. © The Author(s) 2016.

  4. Evidence for a Right-Ear Advantage in Newborn Hearing Screening Results

    PubMed Central

    Hildesheimer, Minka; Roziner, Ilan; Henkin, Yael

    2016-01-01

    The aim of the present study was to investigate the effect of ear asymmetry, order of testing, and gender on transient-evoked otoacoustic emission (TEOAE) pass rates and response levels in newborn hearing screening. The screening results of 879 newborns, of whom 387 (study group) passed screening successfully in only one ear in the first TEOAE screening, but passed screening successfully in both ears thereafter, and 492 (control group) who passed screening successfully in both ears in the first TEOAE, were retrospectively examined for pass rates and TEOAE characteristics. Results indicated a right-ear advantage, as manifested by significantly higher pass rates in the right ear (61% and 39% for right and left ears, respectively) in the study group, and in 1.75 dB greater TEOAE response amplitudes in the control group. The right-ear advantage was enhanced when the first tested ear was the right ear (76%). When the left ear was tested first, pass rates were comparable in both ears. The right-ear advantage in pass rates was similar in females versus males, but manifested in 1.5 dB higher response amplitudes in females compared with males, regardless of the tested ear and order of testing in both study and control groups. The study provides further evidence for the functional lateralization of the auditory system at the cochlear level already apparent soon after birth in both males and females. While order of testing plays a significant role in the asymmetry in pass rates, the innate right-ear advantage seems to be a more dominant contributor. PMID:27927982

  5. [Revisional radical mastoidectomy surgeries--25 cases'experience].

    PubMed

    Li, L; Xie, J; Liu, Y; Gong, S S

    2017-10-07

    Objective: To analyze the risk factors of failure to dry ear after radical mastoidectomy and discuss key points in revisonal surgery. Methods: Clinical data of 25 patients(32 ears) with revisonal mastoidectomy were analyzed. The preoperative temporal bone CT findings, intra-operative findings, surgical procedures, postoperative operating cavities and aural abilities were recorded and analyzed. Results: All patients received preoperative temporal bone CT followed by revisonal radical mastoidectomy under microscope and general anesthesia. Among the revisonal surgeries, 19 ears(59.4%) presented cholesteatoma and 13 ears(40.6%) had no cholesteatoma. In addition, the inadequate opening for mastoid cavity and incompleted removal of the pathological tissues accounted for 90.6%(29/32), the insufficient drainage of surgical cavity for 90.6%(29/32), the lesions in tympanic ostium of eustachian tube for 31.2%(10/32), the improper operation procedures and selection of incision for 15.6%(5/32). As for the re-operation of the modified canal wall down mastoidectomy, tympanoplasty(Ⅱ) plus plastic repairing of cavity of concha were performed in 14 ears(43.8%), the modified canal wall down mastoidectomy, tympanoplasty(Ⅱ) plus reconstruction posterior bony wall of ear canal in 2 ears(6.2%); the modified canal wall down mastoidectomy, tympanoplasty(Ⅲ) plus plastic repairing of cavity of concha in 10 eras(31.3%), the modified canal wall down mastoidectomy, tympanoplasty(Ⅲ) plus reconstruction posterior boney wall of ear canal in 1 ear(3.1%); the radical mastoidectomy plus plastic repairing of cavity of concha in 5 ears(15.6%). Lodoform gauzes were packed in surgical cavity for 2 weeks and the antibiotic was used for 3 days after surgery. All patients had dressing of ears and their ears were dropped with ofloxacin regularly. The dry ear time ranged from 4 to 8 weeks, the average point was the 5th week. During a period of 6-18 months for follow-up, all patients got dried ears. The epithelialization of the operating cavity was well and the tympanic membranes were integrity. There was not pus in surgical cavities. Neither granulation tissue nor cholesteatoma was found to reoccur. Both pure tone air hearing thresholds and air-bone gap decreased in 27 ears after the revisional surgeries, with statistically significant different in comparison to those before the operation ( P <0.05). Conclusions: There are many factors leading to the failure of radical mastoidectomy, including not fully opening of the surgical cavity , incomplete removal of the lesion tissue, poor drainage of surgical cavity, the lesions in the tympanic ostium of eustachian tube, and the improper operation procedures. Treatment strategies were taken according to above factors to obtain dry ear in revisional surgeries.

  6. Non-auditory health effects among air force crew chiefs exposed to high level sound.

    PubMed

    Jensen, Anker; Lund, Søren Peter; Lücke, Thorsten Høgh; Clausen, Ole Voldum; Svendsen, Jørgen Torp

    2009-01-01

    The possibility of non-auditory health effects in connection with occupational exposure to high level sound is supposed by some researchers, but is still debated. Crew chiefs on airfields are exposed to high-level aircraft sound when working close to aircraft with running engines. We compared their health status with a similar control group who were not subject to this specific sound exposure. Health records of 42 crew chiefs were compared to health records of 42 aircraft mechanics and 17 former crew chiefs. The specific sound exposure of crew chiefs was assessed. The number of reported disease cases was generally small, but generally slightly higher among mechanics than among crew chiefs. Diseases of the ear were more frequent among crew chiefs (not significant). Former crew chiefs reported fewer diseases of the ear and more airways infections (both significant). The sound exposure during launch was up to 144 dB (peak) and 124 dB (L(eq) ), but for limited time. The study did not reveal a higher disease frequency in general among crew chiefs. However, it did reveal a tendency to ear diseases, possibly due to their exposure to high-level sound.

  7. Hemodynamic and thermal responses to head and neck cooling in men and women

    NASA Technical Reports Server (NTRS)

    Ku, Y. T.; Montgomery, L. D.; Webbon, B. W.

    1996-01-01

    Personal cooling systems are used to alleviate symptoms of multiple sclerosis and to prevent increased core temperature during daily activities. The objective of this study was to determine the operating characteristics and the physiologic changes produced by short term use of one commercially available thermal control system. A Life Support Systems, Inc. Mark VII portable cooling system and a liquid cooling helmet were used to cool the head and neck regions of 12 female and 12 male subjects (25-55 yr) in this study. The healthy subjects, seated in an upright position at normal room temperature (approximately 21 degrees C), were tested for 30 min with the liquid cooling garment operated at its maximum cooling capacity. Electrocardiograms and scalp and intracranial blood flows were recorded periodically during each test sequence. Scalp, right and left ear, and oral temperatures and cooling system parameters were logged every 5 min. Scalp, right and left ear canal, and oral temperatures were all significantly (P <0.05) reduced by 30 min of head and neck cooling. Oral temperatures decreased approximately 0.2-0.6 degrees C after 30 min and continued to decrease further (approximately 0.1-0.2 degrees C) for a period of approximately 10 min after removal of the cooling helmet. Intracranial blood flow decreased significantly (P < 0.05) during the first 10 min of the cooling period. Both right and left ear temperatures in the women were significantly lower than those of the men during the cooling period. These data indicate that head and neck cooling may be used to reduce core temperature to that needed for symptomatic relief of both male and female multiple sclerosis patients. This study quantifies the operating characteristics of one liquid cooling garment as an example of the information needed to compare the efficiency of other garments operated under different test conditions.

  8. The effects of V2 antagonist (OPC-31260) on endolymphatic hydrops.

    PubMed

    Takeda, Taizo; Sawada, Shoichi; Takeda, Setsuko; Kitano, Hiroya; Suzuki, Mikio; Kakigi, Akinobu; Takeuchi, Shunji

    2003-08-01

    In the present study, two experiments were performed to investigate the influence of OPC-31260 on experimentally induced endolymphatic hydrops in guinea pigs and the regulation of aquaporin-2 (AQP2) mRNA expression in the rat inner ear. In morphological studies, the increases in the ratios of the length of Reissner's membrane (IR-L) and the cross-sectional area of the scala media (IR-S) were quantitatively assessed among normal guinea pigs (normal ears) and three groups with hydropic ears: hydropic ears with no infusion (non-infusion hydropic ears), hydropic ears with an infusion of physiological saline into the scala tympani (saline-infused hydropic ears) and hydropic ears with infusion of 0.3% OPC-31260 into the scala tympani (OPC-infused hydropic ears). IR-Ls in the experimental groups were markedly larger than in the normal ear group, but there was no significant difference among the groups of non-infusion hydropic ears, saline-infused hydropic ears and OPC-infused hydropic ears. The IR-Ss of non-infusion hydropic ears and saline-infused hydropic ears (48.8-49.3%) were statistically different from that of normal ears (6.5%) (Dunnet multiple comparison test, P<0.01). However, IR-S of the OPC-infused hydropic ears (-14.8%) was significantly smaller than those of non-infusion hydropic ears and saline-infused hydropic ears (one-way ANOVA, P<0.01). In the quantitative polymerase chain reaction study, a comparison of the ratio of AQP2 and beta-actin mRNA (MAQP2/Mbeta-actin) was made between water-injected and OPC-31260-injected rats. An intravenous injection of OPC-31260 resulted in a significant decrease in MAQP2/Mbeta-actin both in the cochlea and in the endolymphatic sac (t-test, P<0.001). These results indicate that water homeostasis in the inner ear is regulated via the vasopressin-AQP2 system, and that the vasopressin type-2 antagonist OPC-31260 is a promising drug in the treatment of Meniere's disease.

  9. Update on Middle Ear Barotrauma after Hyperbaric Oxygen Therapy—Insights on Pathophysiology

    PubMed Central

    Lima, Marco Antônio Rios; Farage, Luciano; Cury, Maria Cristina Lancia; Bahamad, Fayez

    2014-01-01

    Introduction Middle ear barotrauma is the most common side effect of hyperbaric oxygen therapy. Knowledge and understanding of its pathophysiology are crucial for an accurate diagnosis and proper decision making about treatment and prevention. Objective Describe up-to-date information on pathophysiology of middle ear barotrauma after hyperbaric oxygen therapy considering the physiology of pressure variation of the middle ear. Data Synthesis Middle ear barotrauma occurs especially during the compression phase of hyperbaric oxygen therapy. The hyperoxic environment in hyperbaric oxygen therapy leads to ventilatory dysfunction of the eustachian tube, especially in monoplace chambers, where the patients are pressurized with 100% O2, favoring middle ear barotrauma. Conclusion The eustachian tube, the tympanic cavity, and mastoid work together in a neural controlled feedback system in which various mechanisms concur for middle ear pressure regulation. PMID:25992091

  10. EARS : Repositioning data management near data acquisition.

    NASA Astrophysics Data System (ADS)

    Sinquin, Jean-Marc; Sorribas, Jordi; Diviacco, Paolo; Vandenberghe, Thomas; Munoz, Raquel; Garcia, Oscar

    2016-04-01

    The EU FP7 Projects Eurofleets and Eurofleets2 are an European wide alliance of marine research centers that aim to share their research vessels, to improve information sharing on planned, current and completed cruises, on details of ocean-going research vessels and specialized equipment, and to durably improve cost-effectiveness of cruises. Within this context logging of information on how, when and where anything happens on board of the vessel is crucial information for data users in a later stage. This forms a primordial step in the process of data quality control as it could assist in the understanding of anomalies and unexpected trends recorded in the acquired data sets. In this way completeness of the metadata is improved as it is recorded accurately at the origin of the measurement. The collection of this crucial information has been done in very different ways, using different procedures, formats and pieces of software in the context of the European Research Fleet. At the time that the Eurofleets project started, every institution and country had adopted different strategies and approaches, which complicated the task of users that need to log general purpose information and events on-board whenever they access a different platform loosing the opportunity to produce this valuable metadata on-board. Among the many goals the Eurofleets project has, a very important task is the development of an "event log software" called EARS (Eurofleets Automatic Reporting System) that enables scientists and operators to record what happens during a survey. EARS will allow users to fill, in a standardized way, the gap existing at the moment in metadata description that only very seldom links data with its history. Events generated automatically by acquisition instruments will also be handled, enhancing the granularity and precision of the event annotation. The adoption of a common procedure to log survey events and a common terminology to describe them is crucial to provide a friendly and successfully metadata on-board creation procedure for the whole the European Fleet. The possibility of automatically reporting metadata and general purpose data, will simplify the work of scientists and data managers with regards to data transmission. An improved accuracy and completeness of metadata is expected when events are recorded at acquisition time. This will also enhance multiple usages of the data as it allows verification of the different requirements existing in different disciplines.

  11. 50 CFR Appendix D to Part 622 - Specifications for Certified BRDs

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... part of the lazy line attachment system (i.e., any mechanism, such as elephant ears or choker straps... is installed, no part of the lazy line attachment system (i.e., any mechanism, such as elephant ears...

  12. 50 CFR Appendix D to Part 622 - Specifications for Certified BRDs

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... part of the lazy line attachment system (i.e., any mechanism, such as elephant ears or choker straps... is installed, no part of the lazy line attachment system (i.e., any mechanism, such as elephant ears...

  13. Delivery of child health services in Indigenous communities: implications for the federal government's emergency intervention in the Northern Territory.

    PubMed

    Bailie, Ross S; Si, Damin; Dowden, Michelle C; Connors, Christine M; O'Donoghue, Lynette; Liddle, Helen E; Kennedy, Catherine M; Cox, Rhonda J; Burke, Hugh P; Thompson, Sandra C; Brown, Alex D H

    2008-05-19

    To describe delivery of child health services in Australian Aboriginal communities, and to identify gaps in services required to improve the health of Aboriginal children. Cross-sectional baseline audit for a quality improvement intervention. 297 children aged at least 3 months and under 5 years in 11 Aboriginal communities in the Northern Territory, Far West New South Wales and Western Australia in 2006. Adherence to guideline-scheduled services including clinical examinations, brief interventions or advice on health-related behaviour and risks, and enquiry regarding social conditions; and recorded follow-up of identified problems. Documentation of delivery of specific clinical examinations (26%-80%) was relatively good, but was poorer for brief interventions or advice on health-related behaviour and risks (5%-36%) and enquiry regarding social conditions (3%-11%). Compared with children in Far West NSW and WA, those attending NT centres were significantly more likely to have a record of growth faltering, underweight, chronic ear disease, anaemia, or chronic respiratory disease (P < 0.005). Only 11%-13% of children with identified social problems had an assessment report on file. An action plan was documented for 22% of children with growth faltering and 13% with chronic ear disease; 43% of children with chronic respiratory disease and 31% with developmental delay had an assessment report on file. Existing systems are not providing for adequate follow-up of identified medical and social problems for children living in remote Aboriginal communities; development of systems for immediate and longer-term sustainable responses to these problems should be a priority. Without effective systems for follow-up, screening children for disease and adverse social circumstances will result in little or no benefit.

  14. Inner Ear Barotrauma After Underwater Pool Competency Training Without the Use of Compressed Air Case and Review.

    PubMed

    McIntire, Sean; Boujie, Lee

    2016-01-01

    Inner ear barotrauma can occur when the gas-filled chambers of the ear have difficulty equalizing pressure with the outside environment after changes in ambient pressure. This can transpire even with small pressure changes. Hypobaric or hyperbaric environments can place significant stress on the structures of the middle and inner ear. If methods to equalize pressure between the middle ear and other connected gas-filled spaces (i.e., Valsalva maneuver) are unsuccessful, middle ear overpressurization can occur. This force can be transmitted to the fluid-filled inner ear, making it susceptible to injury. Damage specifically to the structures of the vestibulocochlear system can lead to symptoms of vertigo, hearing loss, and tinnitus. This article discusses the case of a 23-year-old male Marine who presented with symptoms of nausea and gait instability after performing underwater pool competency exercises to a maximum depth of 13 feet, without breathing compressed air. Diagnosis and management of inner ear barotrauma are reviewed, as is differentiation from inner ear decompression sickness. 2016.

  15. Klippel-Feil syndrome and associated ear anomalies.

    PubMed

    Yildirim, Nadir; Arslanoğlu, Atilla; Mahiroğullari, Mahir; Sahan, Murat; Ozkan, Hüseyin

    2008-01-01

    Klippel-Feil syndrome (KFS) is a congenital segmentation anomaly of the cervical vertebrae that manifests as short neck, low hair line, and limited neck mobility. Various systemic malformations may also accompany the syndrome including wide variety of otopathologies affecting all 3 compartments of the ear (external, middle, and inner ear) as well as internal acoustic canal and vestibular aqueduct. We aimed to investigate these involvements and their clinical correlates in a group of patients with KFS. We present 20 KFS cases, of which 12 (% 60) displayed most of the reported ear abnormalities such as microtia, external ear canal stenosis, chronic ear inflammations and their sequels, anomalies of the tympanic cavity and ossicles, inner ear dysplasies, deformed internal acoustic canal, and wide vestibular aqueduct, which are demonstrated using the methods of otoscopy, audiologic testing, and temporal bone computed tomography. This series represents one of the highest reported rate of ear involvement in KFS. We found no correlation between the identified ear pathologies and the skeletal and extraskeletal malformations. The genetic nature of the syndrome was supported by the existence of affected family members in 4 (20%) of the cases.

  16. Auditory changes in acromegaly.

    PubMed

    Tabur, S; Korkmaz, H; Baysal, E; Hatipoglu, E; Aytac, I; Akarsu, E

    2017-06-01

    The aim of this study is to determine the changes involving auditory system in cases with acromegaly. Otological examinations of 41 cases with acromegaly (uncontrolled n = 22, controlled n = 19) were compared with those of age and gender-matched 24 healthy subjects. Whereas the cases with acromegaly underwent examination with pure tone audiometry (PTA), speech audiometry for speech discrimination (SD), tympanometry, stapedius reflex evaluation and otoacoustic emission tests, the control group did only have otological examination and PTA. Additionally, previously performed paranasal sinus-computed tomography of all cases with acromegaly and control subjects were obtained to measure the length of internal acoustic canal (IAC). PTA values were higher (p < 0.001 for right ears and p = 0.001 for left ears), and SD scores were (p = 0.002 for right ears and p = 0.002 for left ears) lower in acromegalic patients. IAC width in acromegaly group was narrower compared to that in control group (p = 0.03 for right ears and p = 0.02 for left ears). When only cases with acromegaly were taken into consideration, PTA values in left ears had positive correlation with growth hormone and insulin-like growth factor-1 levels (r = 0.4, p = 0.02 and r = 0.3, p = 0.03). Of all cases with acromegaly 13 (32%) had hearing loss in at least one ear, 7 (54%) had sensorineural type and 6 (46%) had conductive type hearing loss. Acromegaly may cause certain changes in the auditory system in cases with acromegaly. The changes in the auditory system may be multifactorial causing both conductive and sensorioneural defects.

  17. 50 CFR Appendix D to Part 622 - Specifications for Certified BRDs

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... attachment system (i.e., any mechanism, such as elephant ears or choker straps, used to attach the lazy line... is installed, no part of the lazy line attachment system (i.e., any mechanism, such as elephant ears...

  18. 50 CFR Appendix D to Part 622 - Specifications for Certified BRDs

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... attachment system (i.e., any mechanism, such as elephant ears or choker straps, used to attach the lazy line... is installed, no part of the lazy line attachment system (i.e., any mechanism, such as elephant ears...

  19. Comparison of visual and electronic devices for individual identification of dromedary camels under different farming conditions.

    PubMed

    Caja, G; Díaz-Medina, E; Salama, A A K; Salama, O A E; El-Shafie, M H; El-Metwaly, H A; Ayadi, M; Aljumaah, R S; Alshaikh, M A; Yahyahoui, M H; Seddik, M M; Hammadi, M; Khorchani, T; Amann, O; Cabrera, S

    2016-08-01

    The camel industry uses traditional (i.e., iron brands and ear tags) and modern (i.e., microchips) identification (ID) systems without having performance results of reference. Previously iron-branded ( = 45; 1 yr) and microchipped ( = 59; 7 yr) camels showed problems of healing (8.6% of brands) and reading (only 42.9% of brands and 69.5% of microchips were readable), which made their use inadvisable. With the aim of proposing suitable ID systems for different farming conditions, an on-field study was performed using a total of 528 dromedaries at 4 different locations (Egypt, = 83; Spain, = 304; Saudi Arabia, = 90; and Tunisia, = 51). The ID devices tested were visual (button ear tags, 28.5 mm diameter, = 178; double flag ear tags, 50 by 15 mm, = 83; both made of polyurethane) and electronic (ear tags, = 90, and rumen boluses, = 555). Electronic ear tags were polyurethane-loop type (75 by 9 mm) with a container in which a 22-mm transponder of full-duplex technology was lodged. Electronic boluses of 7 types, varying in dimensions (50 to 76 mm length, 11 to 21 mm width, and 12.7 to 82.1 g weight) and specific gravity (SG; 1.49 to 3.86) and each of them containing a 31-mm transponder of half-duplex technology, were all administered to the dromedaries at the beginning of the study. When a low-SG bolus was lost, a high-SG bolus was readministered. Readability rates of each ID system were evaluated during 1 to 3 yr, according to device and location, and yearly values were estimated for comparison. On a yearly basis, visual ear tag readability was not fully satisfactory; it was lower for rectangular ear tags (66.3%) than for button ear tags (80.9%). Yearly readability of electronic ear tags was 93.7%. Bolus readability dramatically varied according to their SG; the SG < 2.0 boluses were fully lost after 8 mo. In contrast, the SG > 3.0 boluses were efficiently retained (99.6 to 100%) at all locations. In conclusion, according to the expected long lifespan of camels, low ID performances were observed for iron brands, injectable microchips, and ear tags (visual and electronic), making their use inadvisable as unique ID systems in camels. The high readability of dense electronic boluses recommended their use as a permanent ID device of reference in camels.

  20. Adrenocorticotropin widens the focus of attention in humans. A nonliner electroencephalographic analysis.

    PubMed

    Mölle, M; Albrecht, C; Marshall, L; Fehm, H L; Born, J

    1997-01-01

    This study examined the effects of ACTH 4-10, a fragment of adrenocorticotropin (ACTH) with known central nervous system (CNS) activity, on the dimensional complexity of the ongoing electroencephalographic (EEG) activity. Stressful stimuli cause ACTH to be released from the pituitary, and as a neuropeptide ACTH may concurrently exert adaptive influences on the brain's processing of these stimuli. Previous studies have indicated an impairing influence of ACTH on selective attention. Dimensional complexity of the EEG, which indexes the brain's way of stimulus processing, was evaluated while subjects performed tasks with different attention demands. Sixteen healthy men (23 to 33 years) were tested once after placebo and another time after administration of ACTH 4-10 (1.25 mg intravenously (i.v.), 30 minutes before testing). The EEG was recorded while subjects were presented with a dichotic listening task (consisting of the concurrent presentation of tone pips to the left and right ear). Subjects either a) listened to pips in both ears (divided attention), or b) listened selectively to pips in one ear (selective attention), or c) ignored all pips. Dimensional complexity of the EEG was higher during divided than selective attention. ACTH significantly increased the EEG complexity during selective attention, in particular over the midfrontal cortex (Fz, Cz). The effects support the view of a de-focusing action of ACTH during selective attention that could serve to improve the organism's adaptation to stress stimuli.

  1. Listening with Only a Third Ear

    ERIC Educational Resources Information Center

    Barron, Frank

    1972-01-01

    A review of The Creative Experience" (Grossman), edited by Stanley Rosner and Laurence E. Abt. The Book is essentially a record of conversations with prominent scientists and artists about their life and work. (Author/RY)

  2. Semiautomated Middle Ear Volume Measurement as a Predictor of Postsurgical Outcomes for Congenital Aural Atresia.

    PubMed

    Kabadi, S J; Ruhl, D S; Mukherjee, S; Kesser, B W

    2018-02-01

    Middle ear space is one of the most important components of the Jahrsdoerfer grading system (J-score), which is used to determine surgical candidacy for congenital aural atresia. The purpose of this study was to introduce a semiautomated method for measuring middle ear volume and determine whether middle ear volume, either alone or in combination with the J-score, can be used to predict early postoperative audiometric outcomes. A retrospective analysis was conducted of 18 patients who underwent an operation for unilateral congenital aural atresia at our institution. Using the Livewire Segmentation tool in the Carestream Vue PACS, we segmented middle ear volumes using a semiautomated method for all atretic and contralateral normal ears on preoperative high-resolution CT imaging. Postsurgical audiometric outcome data were then analyzed in the context of these middle ear volumes. Atretic middle ear volumes were significantly smaller than those in contralateral normal ears ( P < .001). Patients with atretic middle ear volumes of >305 mm 3 had significantly better postoperative pure tone average and speech reception thresholds than those with atretic ears below this threshold volume ( P = .01 and P = .006, respectively). Atretic middle ear volume incorporated into the J-score offered the best association with normal postoperative hearing (speech reception threshold ≤ 30 dB; OR = 37.8, P = .01). Middle ear volume, calculated in a semiautomated fashion, is predictive of postsurgical audiometric outcomes, both independently and in combination with the conventional J-score. © 2018 by American Journal of Neuroradiology.

  3. Electronystagmography and audio potentials in space flight

    NASA Technical Reports Server (NTRS)

    Thornton, William E.; Biggers, W. P.; Pool, Sam L.; Thomas, W. G.; Thagard, Norman E.

    1985-01-01

    Beginning with the fourth flight of the Space Transport System (STS-4), objective measurements of inner ear function were conducted in near-zero G conditions in earth orbit. The problem of space motion sickness (SMS) was approached much like any disequilibrium problem encountered clinically. However, objective testing techniques had built-in limitations superimposed by the strict parameters inherent in each mission. An attempt was made to objectively characterize SMS, and to first ascertain whether the objective measurements indicated that this disorder was of peripheral or central origin. Electronystagmography and auditory brain stem response recordings were the primary investigative tools. One of the authors (W.E.T.) was a mission specialist on board the orbiter Challenger on the eighth shuttle mission (STS-8) and had the opportunity to make direct and personal observations regarding SMS, an opportunity which has added immeasurably to our understanding of this disorder. Except for two abnormal ENG records, which remain to be explained, the remaining ENG records and all the ABR records made in the weightless environment of space were normal.

  4. Effects of Stimulus Intensity on Low-Frequency Toneburst Cochlear Microphonic Waveforms.

    PubMed

    Zhang, Ming

    2013-01-02

    This study investigates changes in amplitude and delays in low-frequency toneburst cochlear microphonic (CM) waveforms recorded at the ear canal in response to different stimulus intensities. Ten volunteers aged 20-30 were recruited. Low-frequency CM waveforms at 500 Hz in response to a 14-ms toneburst were recorded from an ear canal electrode using electrocochleography techniques. The data was statistically analyzed in order to confirm whether the differences were significant in the effects of stimulus intensity on the amplitudes and delays of the low-frequency CM waveforms. Electromagnetic interference artifacts can jeopardize CM measurements but such artifacts can be avoided. The CM waveforms can be recorded at the ear canal in response to a toneburst which is longer than that used in ABR measurements. The CM waveforms thus recorded are robust, and the amplitude of CM waveforms is intensity-dependent. In contrast, the delay of CM waveforms is intensity-independent, which is different from neural responses as their delay or latency is intensity-dependent. These findings may be useful for development of the application of CM measurement as a supplementary approach to otoacoustic emission (OAE) measurement in the clinic which is severely affected by background acoustic noise. The development of the application in the assessment of low-frequency cochlear function may become possible if a further series of studies can verify the feasibility, but it is not meant to be a substitute for audiometry or OAE measurements. The measurement of detection threshold of CM waveform responses using growth function approach may become possible in the clinic. The intensity-independent nature of CMs with regards to delay measurements may also become an impacting factor for differential diagnoses and for designing new research studies.

  5. Early hominin auditory ossicles from South Africa

    PubMed Central

    Quam, Rolf M.; de Ruiter, Darryl J.; Masali, Melchiorre; Arsuaga, Juan-Luis; Martínez, Ignacio; Moggi-Cecchi, Jacopo

    2013-01-01

    The middle ear ossicles are only rarely preserved in fossil hominins. Here, we report the discovery of a complete ossicular chain (malleus, incus, and stapes) of Paranthropus robustus as well as additional ear ossicles from Australopithecus africanus. The malleus in both early hominin taxa is clearly human-like in the proportions of the manubrium and corpus, whereas the incus and stapes resemble African and Asian great apes more closely. A deep phylogenetic origin is proposed for the derived malleus morphology, and this may represent one of the earliest human-like features to appear in the fossil record. The anatomical differences found in the early hominin incus and stapes, along with other aspects of the outer, middle, and inner ear, are consistent with the suggestion of different auditory capacities in these early hominin taxa compared with modern humans. PMID:23671079

  6. Vestibular evoked myogenic potential according to middle ear condition in chronic otitis media with tympanic membrane perforation.

    PubMed

    Lee, Jun Seok; Lee, Sun Kyu; Shin, Il Ho; Yeo, Seung Geun; Park, Moon Suh; Byun, Jae Yong

    2014-01-01

    Vestibular evoked myogenic potential (VEMP) function results can vary between individuals with different middle ear conditions. Therefore, by analyzing VEMP results after paper patching, we can predict the condition of the middle ear in chronic otitis media (COM) patients. VEMP responses decrease with impairment of sound transmission, such as in conductive hearing loss (CHL). COM with tympanic membrane (TM) perforation is a common disorder that causes various degrees of CHL. The aim of this study was to evaluate and clarify the VEMP responses in patients with COM with different middle ear pathology. This study included 50 patients with unilateral COM with TM perforation. Initial pure-tone audiometry (PTA) and VEMP responses were recorded. After paper patching, PTA and VEMP were re-performed. Each VEMP response was compared with those of the healthy controls. Moreover, VEMP responses between pre- and post-paper patching were compared. There was a positive correlation between normalizing of VEMP parameters, such as p13 and VEMP asymmetry ratio (VAR), and reduction of air-bone gap in patients with COM after paper patching. The VEMP response in patients with COM with intact ossicle and clean mucosa was more normalized compared with those in patients with COM with different middle ear conditions.

  7. Compensating for ear-canal acoustics when measuring otoacoustic emissions

    PubMed Central

    Charaziak, Karolina K.; Shera, Christopher A.

    2017-01-01

    Otoacoustic emissions (OAEs) provide an acoustic fingerprint of the inner ear, and changes in this fingerprint may indicate changes in cochlear function arising from efferent modulation, aging, noise trauma, and/or exposure to harmful agents. However, the reproducibility and diagnostic power of OAE measurements is compromised by the variable acoustics of the ear canal, in particular, by multiple reflections and the emergence of standing waves at relevant frequencies. Even when stimulus levels are controlled using methods that circumvent standing-wave problems (e.g., forward-pressure-level calibration), distortion-product otoacoustic emission (DPOAE) levels vary with probe location by 10–15 dB near half-wave resonant frequencies. The method presented here estimates the initial outgoing OAE pressure wave at the eardrum from measurements of the conventional OAE, allowing one to separate the emitted OAE from the many reflections trapped in the ear canal. The emitted pressure level (EPL) represents the OAE level that would be recorded were the ear canal replaced by an infinite tube with no reflections. When DPOAEs are expressed using EPL, their variation with probe location decreases to the test–retest repeatability of measurements obtained at similar probe positions. EPL provides a powerful way to reduce the variability of OAE measurements and improve their ability to detect cochlear changes. PMID:28147590

  8. Electroacoustic Evaluation of Frequency-Modulated Receivers Interfaced with Personal Hearing Aids

    ERIC Educational Resources Information Center

    Schafer, Erin C.; Thibodeau, Linda M.; Whalen, Holly S.; Overson, Gary J.

    2007-01-01

    Purpose: The purpose of this study was to compare the electroacoustic outputs of frequency-modulated (FM) systems coupled to hearing aids. Method: Electroacoustic performance of FM systems coupled to hearing aids was determined for 3 FM receivers: body-worn with neck loop, ear-level nonprogrammable, and ear-level programmable. Systems were…

  9. Characteristics of vestibular evoked myogenic potentials in children with enlarged vestibular aqueduct.

    PubMed

    Zhou, Guangwei; Gopen, Quinton

    2011-01-01

    To explore the characteristics of vestibular evoked myogenic potential (VEMP) in children with enlarged vestibular aqueduct (EVA) and to determine the diagnostic value of VEMP testing for this particular inner ear structural anomaly. Retrospective cohort study in a pediatric tertiary care facility. A total of 25 pediatric cases (37 ears) of EVA were identified with complete records, including otologic evaluation, CT scan of the temporal bone, and audiologic assessment. Results of audiometry, tympanometry, and VEMP testing were analyzed. Hearing loss was found in 97% (36/37) of the ears with EVA. Airbone gaps (conductive components) were found in all hearing losses with normal middle ear pressure and mobility. Abnormally low threshold VEMP responses were found in 92% (34/37) of the ears with EVA. VEMP responses were absent unilaterally in three EVA patients who had vestibular complaints. No clear correlation was found between the size of EVA and the audiologic findings. The presence of airbone gaps in children with EVA was found without apparent middle ear pathology. Characteristics of VEMP in EVA were lower thresholds and higher amplitudes despite of the presence of airbone gaps. The abnormally low threshold VEMP responses suggested a "third" window effect in the pathologic condition of EVA. Unilateral absence of VEMP may implicate peripheral vestibular impairment. The findings from our study are helpful in clinical evaluation of young children who usually give limited and ambiguous input regarding their hearing and vestibular problems.

  10. Effect of middle ear fluid on sound transmission and auditory brainstem response in guinea pigs.

    PubMed

    Guan, Xiying; Gan, Rong Z

    2011-07-01

    Combined measurements of middle ear transfer function and auditory brainstem response (ABR) in live guinea pigs with middle ear effusion (MEE) are reported in this paper. The MEE model was created by injecting saline into the middle ear cavity. Vibrations of the tympanic membrane (TM), the tip of the incus, and the round window membrane (RWM) were measured with a laser vibrometer at frequencies of 0.2-40 kHz when the middle ear fluid increased from 0 to 0.2 ml (i.e., full fill of the cavity). The click and pure tone ABRs were recorded as the middle ear fluid increased. Fluid introduction reduced mobility of the TM, incus and RWM mainly at high frequencies (f > 1 kHz). The magnitude of this reduction was related to the volume of fluid. The displacement transmission ratio of the TM to incus varied with frequency and fluid level. The volume displacement ratio of the oval window to round window was approximately 1.0 over most frequencies. Elevation of ABR thresholds and prolongation of ABR latencies were observed as fluid level increased. Reduction of TM displacement correlated well with elevation of ABR threshold at 0.5-8 kHz. Alterations in the ratio of ossicular displacements before and after fluid induction are consistent with fluid-induced changes in complex ossicular motions. Copyright © 2011 Elsevier B.V. All rights reserved.

  11. Effects of the intensity of masking noise on ear canal recorded low-frequency cochlear microphonic waveforms in normal hearing subjects.

    PubMed

    Zhang, Ming

    2014-07-01

    Compared to auditory brainstem responses (ABRs), cochlear microphonics (CMs) may be more appropriate to serve as a supplement to the test of otoacoustic emissions (OAEs). Researchers have shown that low-frequency CMs from the apical cochlea are measurable at the tympanic membrane using high-pass masking noise. Our objective is to study the effect of such noise at different intensities on low-frequency CMs recorded at the ear canal, which is not completely known. Six components were involved in this CM measurement including an ear canal electrode (1), a relatively long and low-frequency toneburst (2), and high-pass masking noise at different intensities (3). The rest components include statistical analysis based on multiple human subjects (4), curve modeling based on amplitudes of CM waveforms (CMWs) and noise intensity (5), and a technique based on electrocochleography (ECochG or ECoG) (6). Results show that low-frequency CMWs appeared clearly. The CMW amplitude decreased with an increase in noise level. It decreased first slowly, then faster, and finally slowly again. In conclusion, when masked with high-pass noise, the low-frequency CMs are measurable at the human ear canal. Such noise reduces the low-frequency CM amplitude. The reduction is noise-intensity dependent but not completely linear. The reduction may be caused by the excited basal cochlea which the low-frequency has to travel and pass through. Although not completely clear, six mechanisms related to such reduction are discussed. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Treatment of Prominent Ears with an Implantable Clip System: A Pilot Study.

    PubMed

    Kang, Norbert V; Kerstein, Ryan L

    2016-03-01

    The earFold™ implantable clip system is a new treatment for prominent ears using an implant made from nickel-titanium alloy, forged into a predetermined shape. The implant is fixed to the cartilage then released, causing the cartilage to fold back. The study aimed to test the safety and behaviour of the implant in vivo. This was a Phase 1, prospective, nonrandomised study. Thirty-nine patients were recruited, from 7 to 57 years of age (22 adults and 17 children). Thirty-seven patients were followed up for a minimum of 18 months. A total of 131 implants was used to treat 75 ears. All treatments were performed under local anaesthetic. Eighteen patients asked for their implants to be left in place permanently. Twenty-one patients agreed to have their implants removed at 6, 12, or 18 months after insertion. Complications affected 8 patients and included extrusion, infection, hypertrophic scarring, and Spock-ear formation. No new complications have arisen in any of the patients since the conclusion of the study, up to a maximum of 47 months. Patients were overwhelmingly satisfied with the outcome of treatment. earFold can be used as a permanent implant to correct prominence of the human ear. It is best suited for treating prominent ears with a poorly formed or absent antihelical fold. The procedure is quick and predictable with a complication rate comparable to suture-based otoplasty techniques. © 2015 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com.

  13. Treatment of Prominent Ears with an Implantable Clip System: A Pilot Study

    PubMed Central

    Kang, Norbert V.; Kerstein, Ryan L.

    2016-01-01

    Background The earFold™ implantable clip system is a new treatment for prominent ears using an implant made from nickel-titanium alloy, forged into a predetermined shape. The implant is fixed to the cartilage then released, causing the cartilage to fold back. Objectives The study aimed to test the safety and behaviour of the implant in vivo. Methods This was a Phase 1, prospective, nonrandomised study. Thirty-nine patients were recruited, from 7 to 57 years of age (22 adults and 17 children). Thirty-seven patients were followed up for a minimum of 18 months. A total of 131 implants was used to treat 75 ears. All treatments were performed under local anaesthetic. Results Eighteen patients asked for their implants to be left in place permanently. Twenty-one patients agreed to have their implants removed at 6, 12, or 18 months after insertion. Complications affected 8 patients and included extrusion, infection, hypertrophic scarring, and Spock-ear formation. No new complications have arisen in any of the patients since the conclusion of the study, up to a maximum of 47 months. Patients were overwhelmingly satisfied with the outcome of treatment. Conclusions earFold can be used as a permanent implant to correct prominence of the human ear. It is best suited for treating prominent ears with a poorly formed or absent antihelical fold. The procedure is quick and predictable with a complication rate comparable to suture-based otoplasty techniques. PMID:26673575

  14. COMPARISON BETWEEN COMPUTED TOMOGRAPHIC CHARACTERISTICS OF THE MIDDLE EAR IN NONBRACHYCEPHALIC AND BRACHYCEPHALIC DOGS WITH OBSTRUCTIVE AIRWAY SYNDROME.

    PubMed

    Salgüero, Raquel; Herrtage, Michael; Holmes, Mark; Mannion, Paddy; Ladlow, Jane

    2016-01-01

    Prevalence of subclinical middle ear lesions in dogs that undergo computed tomography (CT) and magnetic resonance imaging of the head has been reported up to 41%. A predisposition in brachycephalics has been suggested, however evidence-based studies are lacking. Aims of this retrospective cross-sectional study were to compare CT characteristics of the middle ear in groups of nonbrachycephalic and brachycephalic dogs that underwent CT of the head for conditions unrelated to ear disease, and test associations between thickness of the soft palate and presence of subclinical middle ear lesions. One observer recorded CT findings for each dog without knowledge of group status. A total of 65 dogs met inclusion criteria (25 brachycephalic, 40 nonbrachycephalic). Brachycephalic dogs had a significantly thicker bulla wall (P = 2.38 × 10(-26)) and smaller luminal volume (P = 5.74 × 10(-20)), when compared to nonbrachycephalic dogs. Soft palate thickness was significantly greater in the brachycephalic group (P = 2.76 × 10(-9)). Nine of 25 brachycephalic dogs had material in the lumen of the tympanic cavity, compared to zero of 45 of nonbrachycephalics. Within the brachycephalic group, a significant difference in mean soft palate thickness was identified for dogs with material in the middle ear (12.2 mm) vs. air-filled bullae (9 mm; P = 0.016). Findings from the current study supported previous theories that brachycephalic dogs have a greater prevalence of subclinical middle ear effusion and smaller bulla luminal size than nonbrachycephalic dogs. Authors recommend that the bulla lumen volume formula previously developed for mesaticephalic dogs, (-0.612 + 0.757 [lnBW]) be adjusted to 1/3(-0.612 + 0.757 [lnBW]) for brachycephalic breeds. © 2016 American College of Veterinary Radiology.

  15. Presence and seasonal variation of deep diving foraging odontocetes around Kauai, Hawaii using remote autonomous acoustic recorders.

    PubMed

    Au, Whitlow W L; Giorli, Giacomo; Chen, Jessica; Copeland, Adrienne; Lammers, Marc O; Richlen, Michael; Jarvis, Susan; Morrissey, Ronald; Moretti, David

    2014-01-01

    Ecological acoustic recorders (EARs) were moored off the bottom in relatively deep depths (609-710 m) at five locations around the island of Kauai. Initially, the EARs had an analog-to-digital sample rate of 64 kHz with 30-s recordings every 5 min. After the second deployment the sampling rate was increased to 80 kHz in order to better record beaked whale biosonar signals. The results of the 80 kHz recording are discussed in this manuscript and are the results of three deployments over a year's period (January 2010 to January 2011). Five categories of the biosonar signal detection of deep diving odontocetes were created, short-finned pilot whales, sperm whales, beaked whales, Risso's dolphins, and unknown dolphins. During any given day, at least one species of these deep diving odontocetes were detected. On many days, several species were detected. The biosonar signals of short-finned pilot whales were detected the most often with approximately 30% of all the signals, followed by beaked and sperm whales approximately 22% and 21% of all clicks, respectively. The seasonal patterns were not very strong except in the SW location with distinct peak in detection during the months of April-June 2010 period.

  16. Fly-ear inspired acoustic sensors for gunshot localization

    NASA Astrophysics Data System (ADS)

    Liu, Haijun; Currano, Luke; Gee, Danny; Yang, Benjamin; Yu, Miao

    2009-05-01

    The supersensitive ears of the parasitoid fly Ormia ochracea have inspired researchers to develop bio-inspired directional microphone for sound localization. Although the fly ear is optimized for localizing the narrow-band calling song of crickets at 5 kHz, experiments and simulation have shown that it can amplify directional cues for a wide frequency range. In this article, a theoretical investigation is presented to study the use of fly-ear inspired directional microphones for gunshot localization. Using an equivalent 2-DOF model of the fly ear, the time responses of the fly ear structure to a typical shock wave are obtained and the associated time delay is estimated by using cross-correlation. Both near-field and far-field scenarios are considered. The simulation shows that the fly ear can greatly amplify the time delay by ~20 times, which indicates that with an interaural distance of only 1.2 mm the fly ear is able to generate a time delay comparable to that obtained by a conventional microphone pair with a separation as large as 24 mm. Since the parameters of the fly ear structure can also be tuned for muzzle blast and other impulse stimulus, fly-ear inspired acoustic sensors offers great potential for developing portable gunshot localization systems.

  17. Design, Kinematic Optimization, and Evaluation of a Teleoperated System for Middle Ear Microsurgery

    PubMed Central

    Miroir, Mathieu; Nguyen, Yann; Szewczyk, Jérôme; Sterkers, Olivier; Bozorg Grayeli, Alexis

    2012-01-01

    Middle ear surgery involves the smallest and the most fragile bones of the human body. Since microsurgical gestures and a submillimetric precision are required in these procedures, the outcome can be potentially improved by robotic assistance. Today, there is no commercially available device in this field. Here, we describe a method to design a teleoperated assistance robotic system dedicated to the middle ear surgery. Determination of design specifications, the kinematic structure, and its optimization are detailed. The robot-surgeon interface and the command modes are provided. Finally, the system is evaluated by realistic tasks in experimental dedicated settings and in human temporal bone specimens. PMID:22927789

  18. Mastoiditis and facial paralysis as initial manifestations of temporal bone systemic diseases - the significance of the histopathological examination.

    PubMed

    Maniu, Alma Aurelia; Harabagiu, Oana; Damian, Laura Otilia; Ştefănescu, Eugen HoraŢiu; FănuŢă, Bogdan Marius; Cătană, Andreea; Mogoantă, Carmen Aurelia

    2016-01-01

    Several systemic diseases, including granulomatous and infectious processes, tumors, bone disorders, collagen-vascular and other autoimmune diseases may involve the middle ear and temporal bone. These diseases are difficult to diagnose when symptoms mimic acute otomastoiditis. The present report describes our experience with three such cases initially misdiagnosed. Their predominating symptoms were otological with mastoiditis, hearing loss, and subsequently facial nerve palsy. The cases were considered an emergency and the patients underwent tympanomastoidectomy, under the suspicion of otitis media with cholesteatoma, in order to remove a possible abscess and to decompress the facial nerve. The common features were the presence of severe granulation tissue filling the mastoid cavity and middle ear during surgery, without cholesteatoma. The definitive diagnoses was made by means of biopsy of the granulation tissue from the middle ear, revealing granulomatosis with polyangiitis (formerly known as Wegener's granulomatosis) in one case, middle ear tuberculosis and diffuse large B-cell lymphoma respectively. After specific associated therapy facial nerve functions improved, and atypical inflammatory states of the ear resolved. As a group, systemic diseases of the middle ear and temporal bone are uncommon, but aggressive lesions. After analyzing these cases and reviewing the literature, we would like to stress upon the importance of microscopic examination of the affected tissue, required for an accurate diagnosis and effective treatment.

  19. Acoustic Propagation Studies For Sperm Whale Phonation Analysis During LADC Experiments

    NASA Astrophysics Data System (ADS)

    Sidorovskaia, Natalia A.; Ioup, George E.; Ioup, Juliette W.; Caruthers, Jerald W.

    2004-11-01

    The Littoral Acoustic Demonstration Center (LADC) conducted a series of passive acoustic experiments in the Northern Gulf of Mexico and the Ligurian Sea in 2001 and 2002. Environmental and acoustic moorings were deployed in areas of large concentrations of marine mammals (mainly, sperm whales). Recordings and analysis of whale phonations are among the objectives of the project. Each mooring had a single autonomously recording hydrophone (Environmental Acoustic Recording System (EARS)) obtained from the U.S. Naval Oceanographic Office after modification to record signals up to 5,859 Hz in the Gulf of Mexico and up to 12,500 Hz in the Ligurian Sea. Self-recording environmental sensors, attached to the moorings, and concurrent environmental ship surveys provided the environmental data for the experiments. The results of acoustic simulations of long-range propagation of the broad-band (500-6,000 Hz) phonation pulses from a hypothetical whale location to the recording hydrophone in the experimental environments are presented. The utilization of the simulation results for an interpretation of the spectral features observed in whale clicks and for the development of tracking algorithms from single hydrophone recordings based on the identification of direct and surface and bottom reflected arrivals are discussed. [Research supported by ONR.

  20. Zebrafish models of human eye and inner ear diseases.

    PubMed

    Blanco-Sánchez, B; Clément, A; Phillips, J B; Westerfield, M

    2017-01-01

    Eye and inner ear diseases are the most common sensory impairments that greatly impact quality of life. Zebrafish have been intensively employed to understand the fundamental mechanisms underlying eye and inner ear development. The zebrafish visual and vestibulo-acoustic systems are very similar to these in humans, and although not yet mature, they are functional by 5days post-fertilization (dpf). In this chapter, we show how the zebrafish has significantly contributed to the field of biomedical research and how researchers, by establishing disease models and meticulously characterizing their phenotypes, have taken the first steps toward therapies. We review here models for (1) eye diseases, (2) ear diseases, and (3) syndromes affecting eye and/or ear. The use of new genome editing technologies and high-throughput screening systems should increase considerably the speed at which knowledge from zebrafish disease models is acquired, opening avenues for better diagnostics, treatments, and therapies. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Retroauricular skin: a flaps bank for ear reconstruction.

    PubMed

    Cordova, A; D'Arpa, S; Pirrello, R; Giambona, C; Moschella, F

    2008-01-01

    The retroauricular skin has always been given much attention by the reconstructive surgeon for ear and face reconstruction because it is richly vascularised, as many anatomical investigations show, it is hidden behind the ear, its skin is very similar to that of ear and face. All these reasons make it an ideal donor site for ear reconstruction. The authors propose their own algorithm for reconstruction of every kind of anterior defects of the auricle with different Retroauricular Island Flaps (RIFs) based on the location and size of the defect developed over a 16 years single institution's experience with a series of 216 consecutive cases. 216 patients have undergone ear reconstruction with RIFs from 1999 to 2006. In 52 a Superior Pedicle RIF (SP-RIF) was used for defects of the upper half of the auricle. In 68 cases a Perforator RIF (P-RIF) was used for conchal reconstruction. In 96 cases an Inferior Pedicle RIF (IP-RIF) was used for reconstruction of nonmarginal and superficial marginal defects of the auricle. No flap failure was recorded. Excellent morphological reconstruction was obtained with these flaps with no sequealae at the donor site in terms of form and function. Only in the case of P-RIFs the sulcus becomes flat in its central part, but this has never affected the possibility of wearing spectacles. The SP-RIFs may sometimes show some signs of venous stasis that invariably resolve in the first two postoperative days. The retroauricular skin may be considered a flaps bank for ear reconstruction. It offers in fact a great variety of island flaps that are suitable for every kind of loss of substance of the ear, have a safe vascularisation, skin of similar colour and texture, are easy to harvest under local anaesthesia on an outpatient basis and cause no relevant morbidity at the donor site. Location and size of the defects lead the choice between the different types of RIFs.

  2. Neonatal Hairy Ear Pinnae and Gestational Diabetes: Just a Coincidence?

    PubMed

    Valerio, Enrico; Riello, Laura; Chirico, Michela; Semenzato, Rossella; Cutrone, Mario

    2015-01-01

    A newborn girl of 36 weeks gestation was noted to have several anomalies, including bilateral low ear attachment with ear pinnae hypertrichosis, left preauricular pit, micrognathia, short lingual frenulum, and short neck. Pregnancy history revealed poorly controlled maternal gestational diabetes (GD). Localized hypertrichosis of the ear pinnae may represent a potential marker of GD and thereby alert physicians to suspect other potentially GD-associated conditions such as macrosomia, asphyxia, respiratory distress, hypoglycemia, hypocalcemia, hyperbilirubinemia, polycythemia, hypertrophic cardiomyopathy, and congenital anomalies, particularly those involving the central nervous system. © 2015 Wiley Periodicals, Inc.

  3. EARS: Electronic Access to Reference Service.

    PubMed Central

    Weise, F O; Borgendale, M

    1986-01-01

    Electronic Access to Reference Service (EARS) is a front end to the Health Sciences Library's electronic mail system, with links to the online public catalog. EARS, which became operational in September 1984, is accessed by users at remote sites with either a terminal or microcomputer. It is menu-driven, allowing users to request: a computerized literature search, reference information, a photocopy of a journal article, or a book. This paper traces the history of EARS and discusses its use, its impact on library staff and services, and factors that influence the diffusion of new technology. PMID:3779167

  4. EARS: Electronic Access to Reference Service.

    PubMed

    Weise, F O; Borgendale, M

    1986-10-01

    Electronic Access to Reference Service (EARS) is a front end to the Health Sciences Library's electronic mail system, with links to the online public catalog. EARS, which became operational in September 1984, is accessed by users at remote sites with either a terminal or microcomputer. It is menu-driven, allowing users to request: a computerized literature search, reference information, a photocopy of a journal article, or a book. This paper traces the history of EARS and discusses its use, its impact on library staff and services, and factors that influence the diffusion of new technology.

  5. The effect of superior-canal opening on middle-ear input admittance and air-conducted stapes velocity in chinchilla

    PubMed Central

    Songer, Jocelyn E.; Rosowski, John J.

    2009-01-01

    The recent discovery of superior semicircular canal (SC) dehiscence syndrome as a clinical entity affecting both the auditory and vestibular systems has led to the investigation of the impact of a SC opening on the mechanics of hearing. It is hypothesized that the hole in the SC acts as a “third window” in the inner ear which shunts sound-induced stapes volume velocity away from the cochlea through the opening in the SC. To test the hypothesis and to understand the third window mechanisms the middle-ear input admittance and sound-induced stapes velocity were measured in chinchilla before and after surgically introducing a SC opening and after patching the opening. The extent to which patching returned the system to the presurgical state is used as a control criterion. In eight chinchilla ears a statistically significant, reversible increase in low-frequency middle-ear input admittance magnitude occurred as a result of opening the SC. In six ears a statistically significant reversible increase in stapes velocity was observed. Both of these changes are consistent with the hole creating a shunt pathway that increases the cochlear input admittance. PMID:16875223

  6. The effect of superior-canal opening on middle-ear input admittance and air-conducted stapes velocity in chinchilla.

    PubMed

    Songer, Jocelyn E; Rosowski, John J

    2006-07-01

    The recent discovery of superior semicircular canal (SC) dehiscence syndrome as a clinical entity affecting both the auditory and vestibular systems has led to the investigation of the impact of a SC opening on the mechanics of hearing. It is hypothesized that the hole in the SC acts as a "third window" in the inner ear which shunts sound-induced stapes volume velocity away from the cochlea through the opening in the SC. To test the hypothesis and to understand the third window mechanisms the middle-ear input admittance and sound-induced stapes velocity were measured in chinchilla before and after surgically introducing a SC opening and after patching the opening. The extent to which patching returned the system to the presurgical state is used as a control criterion. In eight chinchilla ears a statistically significant, reversible increase in low-frequency middle-ear input admittance magnitude occurred as a result of opening the SC. In six ears a statistically significant reversible increase in stapes velocity was observed. Both of these changes are consistent with the hole creating a shunt pathway that increases the cochlear input admittance.

  7. Tuberculous otitis media: a difficult diagnosis and report of four cases.

    PubMed

    Vital, Victor; Printza, Athanasia; Zaraboukas, Thomas

    2002-01-01

    Tuberculous otitis media is a rare disease. Due to the condition's rarity and its usually indolent course, the diagnosis is often delayed. This can lead to irreversible complications, such as permanent hearing loss or facial nerve paralysis. Tuberculosis of the middle ear cleft, as this disease's first presentation, is indeed very rare. Surgery may be carried out prior to diagnosis occasionally, i.e., middle ear exploration for chronic middle ear disease. We present four cases of tuberculous otitis media which occurred as the first presentation of the disease. The patients did not present with the classic symptoms of middle ear tuberculosis. The diagnosis was based on the histology following middle ear exploration for chronic middle ear disease. None of the patients presented any other systemic involvement. We present a review of this disease's clinical symptoms and the diagnostic tests available.

  8. Chosen Listening Levels for Music With and Without the Use of Hearing Aids.

    PubMed

    Croghan, Naomi B H; Swanberg, Anne M; Anderson, Melinda C; Arehart, Kathryn H

    2016-09-01

    The objective of this study was to describe chosen listening levels (CLLs) for recorded music for listeners with hearing loss in aided and unaided conditions. The study used a within-subject, repeated-measures design with 13 adult hearing-aid users. The music included rock and classical samples with different amounts of audio-industry compression limiting. CLL measurements were taken at ear level (i.e., at input to the hearing aid) and at the tympanic membrane. For aided listening, average CLLs were 69.3 dBA at the input to the hearing aid and 80.3 dBA at the tympanic membrane. For unaided listening, average CLLs were 76.9 dBA at the entrance to the ear canal and 77.1 dBA at the tympanic membrane. Although wide intersubject variability was observed, CLLs were not associated with audiometric thresholds. CLLs for rock music were higher than for classical music at the tympanic membrane, but no differences were observed between genres for ear-level CLLs. The amount of audio-industry compression had no significant effect on CLLs. By describing the levels of recorded music chosen by hearing-aid users, this study provides a basis for ecologically valid testing conditions in clinical and laboratory settings.

  9. Prospective study of inner ear radiation dose and hearing loss in head-and-neck cancer patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pan, Charlie C.; Eisbruch, Avraham; Lee, Julia S.

    Purpose: To determine the relationship between the radiation dose to the inner ear and long-term hearing loss. Methods and Materials: Eligible patients included those receiving curative radiotherapy (RT) for head-and-neck cancer. After enrollment, patients underwent three-dimensional conformal RT planning and delivery (180-200 cGy/fraction) appropriate for their disease site and stage. The inner ear was contoured on axial CT planning images. Dose-volume histograms, as well as the mean and maximal dose for each structure, were calculated. Patients underwent pure tone audiometry at baseline (before treatment) and 1, 6, 12, 24, and 36 months after RT. The threshold level (the greater themore » value, the more hearing loss) in decibels was recorded for 250, 500, 1000, 2000, 4000, and 8000 Hz. For patients receiving predominantly unilateral RT, the contralateral ear served as the de facto control. The differences in threshold level between the ipsilateral and contralateral ears were calculated, and the temporal pattern and dose-response relation of hearing loss were analyzed using statistical methods that take into account the correlation between two ears in the same subject and repeated, sequential measurements of each subject. Results: Of the 40 patients enrolled in this study, 35 qualified for analysis. Four patients who received concurrent chemotherapy and RT were analyzed separately. The 31 unilaterally treated patients received a median dose of 47.4 Gy (range, 14.1-68.8 Gy) to the ipsilateral inner ear and 4.2 Gy (range, 0.5-31.3 Gy) to the contralateral inner ear. Hearing loss was associated with the radiation dose received by the inner ear (loss of 210dB was observed in ears receiving {>=}45 Gy) and was most appreciable in the higher frequencies ({>=}2000 Hz). For a 60-year-old patient with no previous hearing loss in either ear, after receiving 45 Gy, the ipsilateral ear, according to our clinical model, would have a 19.3-dB (95% confidence interval [CI], 15.5-23.0) and 5.4-dB (95% CI, 3.5-7.5) hearing decrement compared with the contralateral ear for 8000 Hz and 1000 Hz, respectively. Age and an initial hearing difference within an ear pair also affected hearing loss. The baseline hearing threshold was inversely related to radiation-induced hearing loss. The degree of hearing loss was dependent on the frequency tested, age, baseline hearing, and baseline difference in hearing between a patient's two ears. Conclusion: High-frequency ({>=}2000 Hz) hearing acuity worsens significantly after RT in a dose-dependent fashion. A larger number of patients needs to be studied to validate these results. This knowledge can be applied to create guidelines regarding future dose limits to the auditory apparatus for patients undergoing head-and-neck RT.« less

  10. Extratympanic observation of middle ear structure using a refractive index matching material (glycerol) and an infrared camera.

    PubMed

    Kong, Soo-Keun; Chon, Kyong-Myong; Goh, Eui-Kyung; Lee, Il-Woo; Wang, Soo-Geun

    2014-05-01

    High-resolution computed tomography has been used mainly in the diagnosis of middle ear disease, such as high-jugular bulb, congenital cholesteatoma, and ossicular disruption. However, certain diagnoses are confirmed through exploratory tympanotomy. There are few noninvasive methods available to observe the middle ear. The purpose of this study was to investigate the effect of glycerol as a refractive index matching material and an infrared (IR) camera system for extratympanic observation. 30% glycerol was used as a refractive index matching material in five fresh cadavers. Each material was divided into four subgroups; GN (glycerol no) group, GO (glycerol out) group, GI (glycerol in) group, and GB (glycerol both) group. A printed letter and middle ear structures on the inside tympanic membrane were observed using a visible and IR ray camera system. In the GB group, there were marked a transilluminated letter or an ossicle on the inside tympanic membrane. In particular, a footplate of stapes was even transilluminated using the IR camera system in the GB group. This method can be useful in the diagnosis of diseases of the middle ear if it is clinically applied through further studies.

  11. Extratympanic observation of middle ear structure using a refractive index matching material (glycerol) and an infrared camera

    NASA Astrophysics Data System (ADS)

    Kong, Soo-Keun; Chon, Kyong-Myong; Goh, Eui-Kyung; Lee, Il-Woo; Wang, Soo-Geun

    2014-05-01

    High-resolution computed tomography has been used mainly in the diagnosis of middle ear disease, such as high-jugular bulb, congenital cholesteatoma, and ossicular disruption. However, certain diagnoses are confirmed through exploratory tympanotomy. There are few noninvasive methods available to observe the middle ear. The purpose of this study was to investigate the effect of glycerol as a refractive index matching material and an infrared (IR) camera system for extratympanic observation. 30% glycerol was used as a refractive index matching material in five fresh cadavers. Each material was divided into four subgroups; GN (glycerol no) group, GO (glycerol out) group, GI (glycerol in) group, and GB (glycerol both) group. A printed letter and middle ear structures on the inside tympanic membrane were observed using a visible and IR ray camera system. In the GB group, there were marked a transilluminated letter or an ossicle on the inside tympanic membrane. In particular, a footplate of stapes was even transilluminated using the IR camera system in the GB group. This method can be useful in the diagnosis of diseases of the middle ear if it is clinically applied through further studies.

  12. Feasible pickup from intact ossicular chain with floating piezoelectric microphone.

    PubMed

    Kang, Hou-Yong; Na, Gao; Chi, Fang-Lu; Jin, Kai; Pan, Tie-Zheng; Gao, Zhen

    2012-02-22

    Many microphones have been developed to meet with the implantable requirement of totally implantable cochlear implant (TICI). However, a biocompatible one without destroying the intactness of the ossicular chain still remains under investigation. Such an implantable floating piezoelectric microphone (FPM) has been manufactured and shows an efficient electroacoustic performance in vitro test at our lab. We examined whether it pick up sensitively from the intact ossicular chain and postulated whether it be an optimal implantable one. Animal controlled experiment: five adult cats (eight ears) were sacrificed as the model to test the electroacoustic performance of the FPM. Three groups were studied: (1) the experiment group (on malleus): the FPM glued onto the handle of the malleus of the intact ossicular chains; (2) negative control group (in vivo): the FPM only hung into the tympanic cavity; (3) positive control group (Hy-M30): a HiFi commercial microphone placed close to the site of the experiment ear. The testing speaker played pure tones orderly ranged from 0.25 to 8.0 kHz. The FPM inside the ear and the HiFi microphone simultaneously picked up acoustic vibration which recorded as .wav files to analyze. The FPM transformed acoustic vibration sensitively and flatly as did the in vitro test across the frequencies above 2.0 kHz, whereas inefficiently below 1.0 kHz for its overloading mass. Although the HiFi microphone presented more efficiently than the FPM did, there was no significant difference at 3.0 kHz and 8.0 kHz. It is feasible to develop such an implantable FPM for future TICIs and TIHAs system on condition that the improvement of Micro Electromechanical System and piezoelectric ceramic material technology would be applied to reduce its weight and minimize its size.

  13. A 1,470 nm diode laser in stapedotomy: Mechanical, thermal, and acoustic effects.

    PubMed

    Koenraads, Simone P C; de Boorder, Tjeerd; Grolman, Wilko; Kamalski, Digna M A

    2017-08-01

    Multiple laser systems have been investigated for their use in stapes surgery in patients with otosclerosis. The diode 1,470 nm laser used in this study is an attractive laser system because it is easily transported and relatively inexpensive in use. This wavelength has relative high absorption in water. This study aimed to investigate the mechanical, thermal, and acoustic effects of the diode 1,470 nm laser on a stapes in an inner ear model. Experiments were performed in an inner ear model including fresh frozen human stapes. High-speed imaging with frame rates up to 2,000 frames per second (f/s) was used to visualize the effects in the vestibule during fenestration of the footplate. A special high-speed color Schlieren technique was used to study thermal effects. The sound produced by perforation was recorded by a hydrophone. Single pulse settings of the diode 1,470 nm laser were 100 ms, 3 W. Diode 1,470 nm laser fenestration showed mechanical effects with small vapor bubbles and pressure waves pushed into the vestibule. Thermal imaging visualized an increase temperature underneath the stapes footplate. Acoustic effects were limited, but larger sounds levels were reached when vaporization bubbles arise and explode in the vestibule. The diode 1,470 nm laser highly absorbs in perilymph and is capable of forming a clear fenestration in the stapes. An overlapping laser pulse will increase the risk of vapor bubbles, pressure waves, and heating the vestibule. As long as we do not know the possible damage of these effects to the inner ear function, it seems advisable to use the laser with less potential harm. Lasers Surg. Med. 49:619-624, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  14. Receiver function imaging of mantle transition zone discontinuities beneath the Tanzania Craton and the Eastern and Western Branches of the East African Rift System

    NASA Astrophysics Data System (ADS)

    Sun, M.; Liu, K. H.; Fu, X.; Gao, S. S.

    2017-12-01

    To investigate the mechanism of initiation and development of the Eastern African Rifting System (EARS) circumfluent the Tanzania Craton (TC), over 7,100 P-to-S radial receiver functions (RFs) recorded by 87 broadband seismic stations are stacked to map the topography of mantle transition zone (MTZ) discontinuities beneath the TC and the Eastern and Western Branches of the EARS. After time-depth conversion using the 1-D IASP91 Earth model, the resulting 410 km (d410) and 660 km (d660) discontinuity apparent depths are found to be greater than the global averages beneath the whole study area, implying slower than normal upper mantle velocities. The mean thickness of the MTZ beneath the Western Branch and TC is about 252 km, which is comparable to the global average and is inconsistent with the existence of present-day thermal upwelling originating from the lower mantle. In contrast, beneath the Eastern Branch, an 30 km thinning of the MTZ is observed from an up to 50 km and 20 km apparent depression of the d410 and d660, respectively. On the basis of previous seismic tomographic results and empirical relationships between velocity and thermal anomalies, we propose that the most plausible explanation for the observations beneath the volcanic Eastern Branch is the existence of a low-velocity layer extending from the surface to the upper MTZ, probably caused by decompression partial melting associated with continental rifting. The observations are in general agreement with an upper mantle origin for the initiation and development of both the Western and Eastern Branches of the EARS beneath the study area.

  15. EAR Program Research Results

    DOT National Transportation Integrated Search

    2013-01-01

    The Exploratory Advanced Research (EAR) Program addresses the need for longer term, higher risk research with the potential for longterm improvements to transportation systems-improvements in planning, building, renewing, and operating safe, congesti...

  16. Associations between psychometrically assessed life history strategy and daily behavior: data from the Electronically Activated Recorder (EAR)

    PubMed Central

    2018-01-01

    Life history theory has generated cogent, well-supported hypotheses about individual differences in human biodemographic traits (e.g., age at sexual maturity) and psychometric traits (e.g., conscientiousness), but little is known about how variation in life history strategy (LHS) is manifest in quotidian human behavior. Here I test predicted associations between the self-report Arizona Life History Battery and frequencies of 12 behaviors observed over 72 h in 91 US college students using the Electronically Activated Recorder (EAR), a method of gathering periodic brief audio recordings as participants go about their daily lives. Bayesian multi-level aggregated binomial regression analysis found no strong associations between ALHB scores and behavior frequencies. One behavior, presence at amusement venues (bars, concerts, sports events) was weakly positively associated with ALHB-assessed slow LHS, contrary to prediction. These results may represent a challenge to the ALHB’s validity. However, it remains possible that situational influences on behavior, which were not measured in the present study, moderate the relationships between psychometrically-assessed LHS and quotidian behavior. PMID:29868275

  17. Associations between psychometrically assessed life history strategy and daily behavior: data from the Electronically Activated Recorder (EAR).

    PubMed

    Manson, Joseph H

    2018-01-01

    Life history theory has generated cogent, well-supported hypotheses about individual differences in human biodemographic traits (e.g., age at sexual maturity) and psychometric traits (e.g., conscientiousness), but little is known about how variation in life history strategy (LHS) is manifest in quotidian human behavior. Here I test predicted associations between the self-report Arizona Life History Battery and frequencies of 12 behaviors observed over 72 h in 91 US college students using the Electronically Activated Recorder (EAR), a method of gathering periodic brief audio recordings as participants go about their daily lives. Bayesian multi-level aggregated binomial regression analysis found no strong associations between ALHB scores and behavior frequencies. One behavior, presence at amusement venues (bars, concerts, sports events) was weakly positively associated with ALHB-assessed slow LHS, contrary to prediction. These results may represent a challenge to the ALHB's validity. However, it remains possible that situational influences on behavior, which were not measured in the present study, moderate the relationships between psychometrically-assessed LHS and quotidian behavior.

  18. The newborn butterfly project: a shortened treatment protocol for ear molding.

    PubMed

    Doft, Melissa A; Goodkind, Alison B; Diamond, Shawn; DiPace, Jennifer I; Kacker, Ashutosh; LaBruna, Anthony N

    2015-03-01

    Secondary to circulating maternal estrogens, a baby's ear cartilage is unusually plastic during the first few weeks of life, providing an opportunity to correct ear deformities by molding. If molding is initiated during the first days of life with a more rigid molding system than previously described in the literature, the authors hypothesized that treatment time would be reduced and the correction rate would increase. An interdisciplinary team identified and assessed all infants born with ear deformities at New York-Presbyterian Hospital/Weill Cornell Medical Center. The authors conducted a prospective, institutional review board-approved study on the first consecutive 100 infants identified. Parents were surveyed initially, immediately after treatment, and at 6 and 12 months. One hundred fifty-eight ears in 96 patients underwent ear molding using the EarWell Infant Ear Correction System. Eighty-two percent of the children had the device placed in the newborn nursery and 95 percent had it placed before 2 weeks of life. Average treatment time was 14 days, and 96 percent of the deformities were corrected. Complications were limited to mild pressure ulcerations. Ninety-nine percent of parents stated that they would have the procedure repeated. The molding period can be reduced from 6 to 8 weeks to 2 weeks by initiating molding during the first weeks of life and using a more secure and rigid device. Through an interdisciplinary approach, the authors were able to identify patients and to correct the deformity earlier and faster than has been previously published, eliminating the need for surgical correction in many children. Therapeutic, IV.

  19. Initiating and developing clinical services, training and research in a low resource setting: the Malawi ENT experience.

    PubMed

    Mulwafu, Wakisa; Nyirenda, Thomas Elliot; Fagan, Johannes J; Bem, Chris; Mlumbe, Kumvana; Chitule, Jean

    2014-07-01

    Sub-Saharan Africa countries like Malawi have a paucity of ear, nose and throat (ENT) data, services and training opportunities. To reflect on new Malawian ENT experience and to propose guidelines to poorly resourced countries. Analysis of data predating and following establishment of ENT services in Malawi. In 2008 the first and only Malawian ENT specialist established ENT services with external funding. Fifteen clinical officers have been trained and a nurse placed at each outreach hospital. In 2012, 15,284 consultations were recorded: 543 (3.6%) from outreach clinics. Forty-nine percent needed medical treatment, while 45% needed medical advice. Surgery was performed on 2.7% of patients; 21% for foreign bodies in the nose and throat and 18% for foreign bodies and biopsies of ears. To establish accessible and sustainable specialist ENT services in a poor country requires building on an established local health delivery system, careful planning and investment in personnel, infrastructure, training and data collection. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  20. Unobtrusive ambulatory EEG using a smartphone and flexible printed electrodes around the ear

    PubMed Central

    Debener, Stefan; Emkes, Reiner; De Vos, Maarten; Bleichner, Martin

    2015-01-01

    This study presents first evidence that reliable EEG data can be recorded with a new cEEGrid electrode array, which consists of ten electrodes printed on flexible sheet and arranged in a c-shape to fit around the ear. Ten participants wore two cEEGrid systems for at least seven hours. Using a smartphone for stimulus delivery and signal acquisition, resting EEG and auditory oddball data were collected in the morning and in the afternoon six to seven hours apart. Analysis of resting EEG data confirmed well-known spectral differences between eyes open and eyes closed conditions. The ERP results confirmed the predicted condition effects with significantly larger P300 amplitudes for target compared to standard tones, and a high test-retest reliability of the P300 amplitude (r > = .74). Moreover, a linear classifier trained on data from the morning session revealed similar performance in classification accuracy for the morning and the afternoon sessions (both > 70%). These findings demonstrate the feasibility of concealed and comfortable brain activity acquisition over many hours. PMID:26572314

  1. Otolaryngological Presentations in Times of Terror: Profile from a Tertiary Health Center in North-Central Nigeria.

    PubMed

    Adoga, Adeyi A; Kokong, Daniel D; Ozoilo, Kenneth N

    2017-07-01

    To report the incidence, socio-demographic characteristics, otorhinolaryngological presentations and outcomes of management of patients at the Jos University Teaching Hospital following terror attacks. A prospective descriptive hospital based study of consecutive patients presenting with ear, nose and throat injuries as a result of bomb blasts and ethno-religious crises within a six-year period and managed at the Jos University Teaching Hospital were studied for age, gender, ear, nose and throat presentations, injury mechanism, interventions and outcome of interventions. A designed proforma was used for data collection. There were 107 ear, nose and throat injuries from a total 468 terror-related injuries consisting of 66 (61.7%) males and 41 (38.3%) females (M:F ratio of 1.6:1), aged between 5 and 77 years (mean= 36.7 years; SD= +/- 16.2). Two peak age incidences of injuries in the first and third decades were recorded. The commonest source of injuries was bomb blasts in 47 (44%) patients. Multiple facial fractures with soft tissue injuries were the commonest seen in 78 (72.9%) patients. The commonest associated injuries were head injuries (n= 36). Ninety-four (87.9%) patients presented via the Accident and Emergency department, 16 (15%) received pre-hospital care. Patients with multiple injuries stayed longer in the hospital ( p -value= 0.028). Complications were recorded in 19 (17.8%) patients. A case fatality rate of 5.6% was recorded. Bomb blasts were the major form of terror attacks in our region. The presence of multiple injuries is a significant negative predictor of patient outcomes.

  2. Hearing loss and the central auditory system: Implications for hearing aids

    NASA Astrophysics Data System (ADS)

    Frisina, Robert D.

    2003-04-01

    Hearing loss can result from disorders or damage to the ear (peripheral auditory system) or the brain (central auditory system). Here, the basic structure and function of the central auditory system will be highlighted as relevant to cases of permanent hearing loss where assistive devices (hearing aids) are called for. The parts of the brain used for hearing are altered in two basic ways in instances of hearing loss: (1) Damage to the ear can reduce the number and nature of input channels that the brainstem receives from the ear, causing plasticity of the central auditory system. This plasticity may partially compensate for the peripheral loss, or add new abnormalities such as distorted speech processing or tinnitus. (2) In some situations, damage to the brain can occur independently of the ear, as may occur in cases of head trauma, tumors or aging. Implications of deficits to the central auditory system for speech perception in noise, hearing aid use and future innovative circuit designs will be provided to set the stage for subsequent presentations in this special educational session. [Work supported by NIA-NIH Grant P01 AG09524 and the International Center for Hearing & Speech Research, Rochester, NY.

  3. Hearing and hearing loss: Causes, effects, and treatments

    NASA Astrophysics Data System (ADS)

    Schmiedt, Richard A.

    2003-04-01

    Hearing loss can have multiple causes. The outer and middle ears are conductive pathways for acoustic energy to the inner ear (cochlea) and help shape our spectral sensitivity. Conductive hearing loss is mechanical in nature such that the energy transfer to the cochlea is impeded, often from eardrum perforations or middle ear fluid buildup. Beyond the middle ear, the cochlea comprises three interdependent systems necessary for normal hearing. The first is that of basilar-membrane micromechanics including the outer hair cells. This system forms the basis of the cochlear amplifier and is the most vulnerable to noise and drug exposure. The second system comprises the ion pumps in the lateral wall tissues of the cochlea. These highly metabolic cells provide energy to the cochlear amplifier in the form of electrochemical potentials. This second system is particularly vulnerable to the effects of aging. The third system comprises the inner hair cells and their associated sensory nerve fibers. This system is the transduction stage, changing mechanical vibrations to nerve impulses. New treatments for hearing loss are on the horizon; however, at present the best strategy is avoidance of cochlear trauma and the proper use of hearing aids. [Work supported by NIA and MUSC.

  4. Miniature, minimally invasive, tunable endoscope for investigation of the middle ear.

    PubMed

    Pawlowski, Michal E; Shrestha, Sebina; Park, Jesung; Applegate, Brian E; Oghalai, John S; Tkaczyk, Tomasz S

    2015-06-01

    We demonstrate a miniature, tunable, minimally invasive endoscope for diagnosis of the auditory system. The probe is designed to sharply image anatomical details of the middle ear without the need for physically adjusting the position of the distal end of the endoscope. This is achieved through the addition of an electrowetted, tunable, electronically-controlled lens to the optical train. Morphological imaging is enabled by scanning light emanating from an optical coherence tomography system. System performance was demonstrated by imaging part of the ossicular chain and wall of the middle ear cavity of a normal mouse. During the experiment, we electronically moved the plane of best focus from the incudo-stapedial joint to the stapedial artery. Repositioning the object plane allowed us to image anatomical details of the middle ear beyond the depth of field of a static optical system. We also demonstrated for the first time to our best knowledge, that an optical system with an electrowetted, tunable lens may be successfully employed to measure sound-induced vibrations within the auditory system by measuring the vibratory amplitude of the tympanic membrane in a normal mouse in response to pure tone stimuli.

  5. The zinc finger transcription factor Gfi1, implicated in lymphomagenesis, is required for inner ear hair cell differentiation and survival

    NASA Technical Reports Server (NTRS)

    Wallis, Deeann; Hamblen, Melanie; Zhou, Yi; Venken, Koen J T.; Schumacher, Armin; Grimes, H. Leighton; Zoghbi, Huda Y.; Orkin, Stuart H.; Bellen, Hugo J.

    2003-01-01

    Gfi1 was first identified as causing interleukin 2-independent growth in T cells and lymphomagenesis in mice. Much work has shown that Gfi1 and Gfi1b, a second mouse homolog, play pivotal roles in blood cell lineage differentiation. However, neither Gfi1 nor Gfi1b has been implicated in nervous system development, even though their invertebrate homologues, senseless in Drosophila and pag-3 in C. elegans are expressed and required in the nervous system. We show that Gfi1 mRNA is expressed in many areas that give rise to neuronal cells during embryonic development in mouse, and that Gfi1 protein has a more restricted expression pattern. By E12.5 Gfi1 mRNA is expressed in both the CNS and PNS as well as in many sensory epithelia including the developing inner ear epithelia. At later developmental stages, Gfi1 expression in the ear is refined to the hair cells and neurons throughout the inner ear. Gfi1 protein is expressed in a more restricted pattern in specialized sensory cells of the PNS, including the eye, presumptive Merkel cells, the lung and hair cells of the inner ear. Gfi1 mutant mice display behavioral defects that are consistent with inner ear anomalies, as they are ataxic, circle, display head tilting behavior and do not respond to noise. They have a unique inner ear phenotype in that the vestibular and cochlear hair cells are differentially affected. Although Gfi1-deficient mice initially specify inner ear hair cells, these hair cells are disorganized in both the vestibule and cochlea. The outer hair cells of the cochlea are improperly innervated and express neuronal markers that are not normally expressed in these cells. Furthermore, Gfi1 mutant mice lose all cochlear hair cells just prior to and soon after birth through apoptosis. Finally, by five months of age there is also a dramatic reduction in the number of cochlear neurons. Hence, Gfi1 is expressed in the developing nervous system, is required for inner ear hair cell differentiation, and its loss causes programmed cell death.

  6. Transtympanic injections of N-acetylcysteine for the prevention of cisplatin-induced ototoxicity: a feasible method with promising efficacy.

    PubMed

    Riga, Maria G; Chelis, Leonidas; Kakolyris, Stylianos; Papadopoulos, Stergios; Stathakidou, Sofia; Chamalidou, Eleni; Xenidis, Nikolaos; Amarantidis, Kyriakos; Dimopoulos, Prokopios; Danielides, Vasilios

    2013-02-01

    Ototoxicity is a common and irreversible adverse effect of cisplatin treatment with great impact on the patients' quality of life. N-acetylcysteine is a low-molecular-weight agent which has shown substantial otoprotective activity. The role of transtympanic infusions of N-acetylcysteine was examined in a cohort of patients treated with cisplatin-based regimens. Twenty cisplatin-treated patients were subjected, under local anesthesia, to transtympanic N-acetylcysteine (10%) infusions in 1 ear, during the hydration procedure preceding intravenous effusion of cisplatin. The contralateral ear was used as control. The number of transtympanic infusions was respective to the number of administered cycles. Hearing acuity was evaluated before each cycle with pure tone audiometry by an audiologist blinded to the treated ear. A total of 84 transtympanic infusions were performed. In treated ears, no significant changes in auditory thresholds were recorded. In the control ears cisplatin induced a significant decrease of auditory thresholds at the 8000 Hz frequency band (P=0.008). At the same frequency (8000 Hz), the changes in auditory thresholds were significantly larger for the control ears than the treated ones (P=0.005). An acute pain starting shortly after the injection and lasting for a few minutes seemed to be the only significant adverse effect. Transtympanic injections of N-acetylcysteine seem to be a feasible and effective otoprotective strategy for the prevention of cisplatin-induced ototoxicity. Additional studies are required to further clarify the efficiency of this treatment and determine the optimal dosage and protocol.

  7. Vitamin D receptor deficiency impairs inner ear development in zebrafish

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kwon, Hye-Joo; Biology Department, Princess Nourah University, Riyadh 11671

    The biological actions of vitamin D are largely mediated through binding to the vitamin D receptor (VDR), a member of the nuclear hormone receptor family, which regulates gene expression in a wide variety of tissues and cells. Mutations in VDR gene have been implicated in ear disorders (hearing loss and balance disorder) but the mechanisms are not well established. In this study, to investigate the role of VDR in inner ear development, morpholino-mediated gene knockdown approaches were used in zebrafish model system. Two paralogs for VDR, vdra and vdrb, have been identified in zebrafish. Knockdown of vdra had no effectmore » on ear development, whereas knockdown of vdrb displayed morphological ear defects including smaller otic vesicles with malformed semicircular canals and abnormal otoliths. Loss-of-vdrb resulted in down-regulation of pre-otic markers, pax8 and pax2a, indicating impairment of otic induction. Furthermore, zebrafish embryos lacking vdrb produced fewer sensory hair cells in the ears and showed disruption of balance and motor coordination. These data reveal that VDR signaling plays an important role in ear development. - Highlights: • VDR signaling is involved in ear development. • Knockdown of vdrb causes inner ear malformations during embryogenesis. • Knockdown of vdrb affects otic placode induction. • Knockdown of vdrb reduces the number of sensory hair cells in the inner ear. • Knockdown of vdrb disrupts balance and motor coordination.« less

  8. Probe-tube microphone measures in hearing-impaired children and adults.

    PubMed

    Barlow, N L; Auslander, M C; Rines, D; Stelmachowicz, P G

    1988-10-01

    This study was designed to investigate the reliability of real-ear measurements of sound pressure level (SPL) and to compare these values with two coupler measures of SPL. A commercially available probe tube microphone system was used to measure real ear SPL in both children and adults. Test-retest reliability decreased as a function of frequency for both groups and, in general, was slightly poorer for the children. For both groups, coupler to real ear differences were larger for the 2 cm3 coupler than for the reduced volume coupler; however, no significant differences were observed between groups. In addition, a measure of ear canal volume was not found to be a good predictor of coupler to real ear discrepancies.

  9. Ensemble training to improve recognition using 2D ear

    NASA Astrophysics Data System (ADS)

    Middendorff, Christopher; Bowyer, Kevin W.

    2009-05-01

    The ear has gained popularity as a biometric feature due to the robustness of the shape over time and across emotional expression. Popular methods of ear biometrics analyze the ear as a whole, leaving these methods vulnerable to error due to occlusion. Many researchers explore ear recognition using an ensemble, but none present a method for designing the individual parts that comprise the ensemble. In this work, we introduce a method of modifying the ensemble shapes to improve performance. We determine how different properties of an ensemble training system can affect overall performance. We show that ensembles built from small parts will outperform ensembles built with larger parts, and that incorporating a large number of parts improves the performance of the ensemble.

  10. [The effect of OSAHS on middle ear and inner ear vestibule function advances].

    PubMed

    Li, K L; Li, J R

    2016-05-20

    Obstructive sleep apnea hypopnea syndrome(OSAHS) as a common frequentlyoccurring disease, it can cause repeated episodes of hypoxaemia and hypercapnia during sleep. With long period of hypoxaemia, obvious pathological changes and dysfunction emerged in heart,brain and lung then all kinds of clinical symptoms appear. Because of the middle ear and inner ear themselves anatomical characteristics and blood supply of regulating mechanism, they often has been damaged before the other important organ damage. As scholars have indepth study of the auditory system complications in patients with OSAHS, various influence of OSAHS on the middle ear,inner ear also gradually be known.This paper will review the effect of OSAHS on middle ear, inner ear and vestibule function, hope to have some application value for clinical work. Copyright© by the Editorial Department of Journal of Clinical Otorhinolaryngology Head and Neck Surgery.

  11. Finite element modeling of acousto-mechanical coupling in the cat middle ear

    PubMed Central

    Tuck-Lee, James P.; Pinsky, Peter M.; Steele, Charles R.; Puria, Sunil

    2008-01-01

    The function of the middle ear is to transfer acoustic energy from the ear canal to the cochlea. An essential component of this system is the tympanic membrane. In this paper, a new finite element model of the middle ear of the domestic cat is presented, generated in part from cadaver anatomy via microcomputed tomographic imaging. This model includes a layered composite model of the eardrum, fully coupled with the acoustics in the ear canal and middle-ear cavities. Obtaining the frequency response from 100 Hz to 20 kHz is a computationally challenging task, which has been accomplished by using a new adaptive implementation of the reduced-order matrix Padé-via-Lanczos algorithm. The results are compared to established physiological data. The fully coupled model is applied to study the role of the collagen fiber sublayers of the eardrum and to investigate the relationship between the structure of the middle-ear cavities and its function. Three applications of this model are presented, demonstrating the shift in the middle-ear resonance due to the presence of the septum that divides the middle-ear cavity space, the significance of the radial fiber layer on high frequency transmission, and the importance of the transverse shear modulus in the eardrum microstructure. PMID:18646982

  12. Human middle-ear model with compound eardrum and airway branching in mastoid air cells

    PubMed Central

    Keefe, Douglas H.

    2015-01-01

    An acoustical/mechanical model of normal adult human middle-ear function is described for forward and reverse transmission. The eardrum model included one component bound along the manubrium and another bound by the tympanic cleft. Eardrum components were coupled by a time-delayed impedance. The acoustics of the middle-ear cleft was represented by an acoustical transmission-line model for the tympanic cavity, aditus, antrum, and mastoid air cell system with variable amounts of excess viscothermal loss. Model parameters were fitted to published measurements of energy reflectance (0.25–13 kHz), equivalent input impedance at the eardrum (0.25–11 kHz), temporal-bone pressure in scala vestibuli and scala tympani (0.1–11 kHz), and reverse middle-ear impedance (0.25–8 kHz). Inner-ear fluid motion included cochlear and physiological third-window pathways. The two-component eardrum with time delay helped fit intracochlear pressure responses. A multi-modal representation of the eardrum and high-frequency modeling of the middle-ear cleft helped fit ear-canal responses. Input reactance at the eardrum was small at high frequencies due to multiple modal resonances. The model predicted the middle-ear efficiency between ear canal and cochlea, and the cochlear pressures at threshold. PMID:25994701

  13. Human middle-ear model with compound eardrum and airway branching in mastoid air cells.

    PubMed

    Keefe, Douglas H

    2015-05-01

    An acoustical/mechanical model of normal adult human middle-ear function is described for forward and reverse transmission. The eardrum model included one component bound along the manubrium and another bound by the tympanic cleft. Eardrum components were coupled by a time-delayed impedance. The acoustics of the middle-ear cleft was represented by an acoustical transmission-line model for the tympanic cavity, aditus, antrum, and mastoid air cell system with variable amounts of excess viscothermal loss. Model parameters were fitted to published measurements of energy reflectance (0.25-13 kHz), equivalent input impedance at the eardrum (0.25-11 kHz), temporal-bone pressure in scala vestibuli and scala tympani (0.1-11 kHz), and reverse middle-ear impedance (0.25-8 kHz). Inner-ear fluid motion included cochlear and physiological third-window pathways. The two-component eardrum with time delay helped fit intracochlear pressure responses. A multi-modal representation of the eardrum and high-frequency modeling of the middle-ear cleft helped fit ear-canal responses. Input reactance at the eardrum was small at high frequencies due to multiple modal resonances. The model predicted the middle-ear efficiency between ear canal and cochlea, and the cochlear pressures at threshold.

  14. Otic drug delivery systems: formulation principles and recent developments.

    PubMed

    Liu, Xu; Li, Mingshuang; Smyth, Hugh; Zhang, Feng

    2018-04-25

    Disorders of the ear severely impact the quality of life of millions of people, but the treatment of these disorders is an ongoing, but often overlooked challenge particularly in terms of formulation design and product development. The prevalence of ear disorders has spurred significant efforts to develop new therapeutic agents, but perhaps less innovation has been applied to new drug delivery systems to improve the efficacy of ear disease treatments. This review provides a brief overview of physiology, major diseases, and current therapies used via the otic route of administration. The primary focuses are on the various administration routes and their formulation principles. The article also presents recent advances in otic drug deliveries as well as potential limitations. Otic drug delivery technology will likely evolve in the next decade and more efficient or specific treatments for ear disease will arise from the development of less invasive drug delivery methods, safe and highly controlled drug delivery systems, and biotechnology targeting therapies.

  15. Cilia and Ear.

    PubMed

    Piatti, Gioia; De Santi, Maria Margherita; Torretta, Sara; Pignataro, Lorenzo; Soi, Daniela; Ambrosetti, Umberto

    2017-04-01

    To investigate the prevalence of otological complications derived from primary ciliary dyskinesia (PCD) in adulthood. Twenty-three patients with diagnosed PCD underwent medical history aimed at recording the presence of ear, nose, and throat manifestations (ENT) and any surgical treatments. The ENT objectivity was annotated, and then patients were subjected to audiometric test, tympanometry, registration of otoacoustic emission, and vestibular evaluation. Otitis media with chronic middle ear effusion (OME) during childhood was reported in 52% of the subjects, no patient had undergone ear surgery, and only 2 patients had an episode of otitis in the last year. Eleven of 23 patients showed normal hearing, 11 had a conductive hearing impairment, and 1 showed a severe sensorineural hearing loss unrelated to the syndrome. The bilateral stapedial reflex was only found in all cases of normoacusia and type A tympanogram, distortion product otoacoustic emissions (DPOAE) were present in 8 patients, and no patient had vestibular alterations. Our study confirms a very frequent prevalence of OME in PCD during childhood. Careful monitoring of otological complications of the syndrome is always desirable, also given the high presence in adults of other manifestations in the upper airways, such as chronic rhinosinusitis and nasal polyposis.

  16. Auditory Spatial Perception: Auditory Localization

    DTIC Science & Technology

    2012-05-01

    cochlear nucleus, TB – trapezoid body, SOC – superior olivary complex, LL – lateral lemniscus, IC – inferior colliculus. Adapted from Aharonson and...Figure 5. Auditory pathways in the central nervous system. LE – left ear, RE – right ear, AN – auditory nerve, CN – cochlear nucleus, TB...fibers leaving the left and right inner ear connect directly to the synaptic inputs of the cochlear nucleus (CN) on the same (ipsilateral) side of

  17. A novel vehicle for local protein delivery to the inner ear: injectable and biodegradable thermosensitive hydrogel loaded with PLGA nanoparticles.

    PubMed

    Dai, Juan; Long, Wei; Liang, Zhongping; Wen, Lu; Yang, Fan; Chen, Gang

    2018-01-01

    Delivery of biomacromolecular drugs into the inner ear is challenging, mainly because of their inherent instability as well as physiological and anatomical barriers. Therefore, protein-friendly, hydrogel-based delivery systems following local administration are being developed for inner ear therapy. Herein, biodegradable poly(lactic-co-glycolic acid) (PLGA) nanoparticles (NPs) containing interferon α-2 b (IFN α-2 b) were loaded in chitosan/glycerophosphate (CS/GP)-based thermosensitive hydrogel for IFN delivery by intratympanic injection. The injectable hydrogel possessed a physiological pH and formed semi-solid gel at 37 °C, with good swelling and deswelling properties. The CS/GP hydrogel could slowly degrade as visualized by scanning electron microscopy (SEM). The presence of NPs in CS/GP gel largely influenced in vitro drug release. In the guinea pig cochlea, a 1.5- to 3-fold increase in the drug exposure time of NPs-CS/GP was found than those of the solution, NPs and IFN-loaded hydrogel. Most importantly, a prolonged residence time was attained without obvious histological changes in the inner ear. This biodegradable, injectable, and thermosensitive NPs-CS/GP system may allow longer delivery of protein drugs to the inner ear, thus may be a potential novel vehicle for inner ear therapy.

  18. Auditory Evoked Potential Mismatch Negativity in Normal-Hearing Adults

    PubMed Central

    Schwade, Laura Flach; Didoné, Dayane Domeneghini; Sleifer, Pricila

    2017-01-01

    Introduction  Mismatch Negativity (MMN) corresponds to a response of the central auditory nervous system. Objective  The objective of this study is to analyze MMN latencies and amplitudes in normal-hearing adults and compare the results between ears, gender and hand dominance. Methods  This is a cross-sectional study. Forty subjects participated, 20 women and 20 men, aged 18 to 29 years and having normal auditory thresholds. A frequency of 1000Hz (standard stimuli) and 2000Hz (deviant stimuli) was used to evoked the MMN. Results  Mean latencies in the right ear were 169.4ms and 175.3ms in the left ear, with mean amplitudes of 4.6µV in the right ear and 4.2µV in the left ear. There was no statistically significant difference between ears. The comparison of latencies between genders showed a statistically significant difference for the right ear, being higher in the men than in women. There was no significant statistical difference between ears for both right-handed and left-handed group. However, the results indicated that the latency of the right ear was significantly higher for the left handers than the right handers. We also found a significant result for the latency of the left ear, which was higher for the right handers. Conclusion  It was possible to obtain references of values for the MMN. There are no differences in the MMN latencies and amplitudes between the ears. Regarding gender, the male group presented higher latencies in relation to the female group in the right ear. Some results indicate that there is a significant statistical difference of the MMN between right- and left-handed individuals. PMID:28680490

  19. SENSORY HAIR CELL REGENERATION IN THE ZEBRAFISH LATERAL LINE

    PubMed Central

    Lush, Mark E.; Piotrowski, Tatjana

    2014-01-01

    Damage or destruction of sensory hair cells in the inner ear leads to hearing or balance deficits that can be debilitating, especially in older adults. Unfortunately, the damage is permanent, as regeneration of the inner ear sensory epithelia does not occur in mammals. Zebrafish and other non-mammalian vertebrates have the remarkable ability to regenerate sensory hair cells and understanding the molecular and cellular basis for this regenerative ability will hopefully aid us in designing therapies to induce regeneration in mammals. Zebrafish not only possess hair cells in the ear but also in the sensory lateral line system. Hair cells in both organs are functionally analogous to hair cells in the inner ear of mammals. The lateral line is a mechanosensory system found in most aquatic vertebrates that detects water motion and aids in predator avoidance, prey capture, schooling and mating. Although hair cell regeneration occurs in both the ear and lateral line, most research to date has focused on the lateral line due to its relatively simple structure and accessibility. Here we review the recent discoveries made during the characterization of hair cell regeneration in zebrafish. PMID:25045019

  20. Primary investigations on the potential of a novel diode pumped Er:YAG laser system for middle ear surgery

    NASA Astrophysics Data System (ADS)

    Stock, Karl; Wurm, Holger; Hausladen, Florian

    2016-02-01

    Flashlamp pumped Er:YAG lasers are successfully used clinically for both precise soft and hard tissue ablation. Since several years a novel diode pumped Er:YAG laser system (Pantec Engineering AG) is available, with mean laser power up to 40 W and pulse repetition rate up to 1 kHz. The aim of the study was to investigate the suitability of the laser system specifically for stapedotomy. Firstly an experimental setup was realized with a beam focusing unit and a computer controlled translation stage to move the samples (slices of porcine bone) with a defined velocity while irradiation with various laser parameters. A microphone was positioned in a defined distance to the ablation point and the resulting acoustic signal of the ablation process was recorded. For comparison, measurements were also performed with a flash lamp pumped Er:YAG laser system. After irradiation the resulting ablation quality and efficacy were determined using light microscopy. Using a high speed camera and "Töpler-Schlierentechnik" the cavitation bubble in water after perforation of a bone slice was investigated. The results show efficient bone ablation using the diode pumped Er:YAG laser system. Also a decrease of the sound level and of the cavitation bubble volume was observed with decreasing pulse duration. Higher repetition rates lead to a slightly increase of thermal side effects but have no influence on the ablation efficiency. In conclusion, these first experiments demonstrate the high potential of the diode pumped Er:YAG laser system for use in middle ear surgery.

  1. Jewelry cleaners

    MedlinePlus

    ... swelling (may also cause breathing difficulty) EYES, EARS, NOSE, AND THROAT Severe pain in the throat Severe pain or burning in the nose, eyes, ears, lips, or tongue Vision loss GASTROINTESTINAL SYSTEM ... pain (severe) Bloody stools Burns and possible holes of ...

  2. Vitamin D receptor deficiency impairs inner ear development in zebrafish.

    PubMed

    Kwon, Hye-Joo

    2016-09-16

    The biological actions of vitamin D are largely mediated through binding to the vitamin D receptor (VDR), a member of the nuclear hormone receptor family, which regulates gene expression in a wide variety of tissues and cells. Mutations in VDR gene have been implicated in ear disorders (hearing loss and balance disorder) but the mechanisms are not well established. In this study, to investigate the role of VDR in inner ear development, morpholino-mediated gene knockdown approaches were used in zebrafish model system. Two paralogs for VDR, vdra and vdrb, have been identified in zebrafish. Knockdown of vdra had no effect on ear development, whereas knockdown of vdrb displayed morphological ear defects including smaller otic vesicles with malformed semicircular canals and abnormal otoliths. Loss-of-vdrb resulted in down-regulation of pre-otic markers, pax8 and pax2a, indicating impairment of otic induction. Furthermore, zebrafish embryos lacking vdrb produced fewer sensory hair cells in the ears and showed disruption of balance and motor coordination. These data reveal that VDR signaling plays an important role in ear development. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. How minute sooglossid frogs hear without a middle ear.

    PubMed

    Boistel, Renaud; Aubin, Thierry; Cloetens, Peter; Peyrin, Françoise; Scotti, Thierry; Herzog, Philippe; Gerlach, Justin; Pollet, Nicolas; Aubry, Jean-François

    2013-09-17

    Acoustic communication is widespread in animals. According to the sensory drive hypothesis [Endler JA (1993) Philos Trans R Soc Lond B Biol Sci 340(1292):215-225], communication signals and perceptual systems have coevolved. A clear illustration of this is the evolution of the tetrapod middle ear, adapted to life on land. Here we report the discovery of a bone conduction-mediated stimulation of the ear by wave propagation in Sechellophryne gardineri, one of the world's smallest terrestrial tetrapods, which lacks a middle ear yet produces acoustic signals. Based on X-ray synchrotron holotomography, we measured the biomechanical properties of the otic tissues and modeled the acoustic propagation. Our models show how bone conduction enhanced by the resonating role of the mouth allows these seemingly deaf frogs to communicate effectively without a middle ear.

  4. [Evaluation of a context sensitive system for intra-operative usage of the electronic patient record].

    PubMed

    Dressler, C R; Fischer, M; Burgert, O; Strauß, G

    2012-06-01

    This article analyzes the usage of an electronic patient record (EPR), which may be accessed intra-operatively by the surgeon. The focus lies on the automatic prioritization of documents to dramatically reduce the surgeon's interaction with the EPR system. An EPR system has been developed, which displays documents in accordance to the current procedure. The system is controlled by a foot switch and the documents are displayed on a large-scale screen in the operating room. The usage of the system by 2 surgeons has been recorded in clinical routine. 55 surgical procedures have been recorded. The EPR system has been used 2 times per procedure in average for surgeries at the middle ear, for surgeries of the paranasal sinuses, it has been used 1.3 times per procedure. The EPR-system has been used pre-operatively in 58% of cases. The surgeons did not have to interact with the EPR system for more than the half of the procedures to view the desired document. The existence of digitized documents in a clinic does not automatically lead to improved workflows. The evaluated EPR system presented the patient data in a simple and comfortable way. The extensive pre-operative usage had not been expected. Because of the low barrier to view patient data, higher patient safety may be assumed. On the other hand, the surgeon could be encouraged to skip the important preparation before the procedure. Due to the low pervasiveness of medical communication standards at this time, the integrated connection between clinic IT and an EPR system would nowadays only be possible by great efforts. © Georg Thieme Verlag KG Stuttgart · New York.

  5. Daily tympanometry for high-resolution measurement of the time between onset of cold-like illness and middle ear effusion.

    PubMed

    Doyle, William J; Winther, Birgit; Alper, Cuneyt M

    2008-06-01

    Tympanometry is a simple method to assess middle ear pressure (MEP) and the presence of middle ear effusion (MEE), a marker of otitis media (OM). To determine whether daily parental tympanometry and illness sign recording in their children can be used to define the time between onsets of cold-like illness (CLI) and MEE at high resolution. Prospective, longitudinal, 7 month, daily follow-up on 169 children aged 1 through 8.6 years. Tympanograms and illness were recorded daily by a parent. Tympanograms were examined, rejected if artifactual, and MEP data were entered into a database, with "flat tympanograms" coded as -400 mm H2O = MEE. The incidence and burden of CLIs (>2 days) were calculated, and for each CLI, the presence/absence of concurrent MEE (>2 days) was determined. For each child, the average MEP for CLI and nonCLI days was calculated. Paired CLI and tympanometric results were aligned and the days between event onsets determined. Stepwise regression was used to assign risk predictors for the measured outcomes. A total of 566 CLIs were recorded, and the average CLI burden/child was 16%. Age was a significant predictor of CLI incidence/child, and age, history of colds, and daily environment were predictors of CLI-burden/child. Of the 433 evaluable CLI episodes, MEE was a complication in 37%, and MEE with a CLI was predicted by age, OM history, and environment. MEP was significantly more negative during CLI episodes, and the magnitude was predicted by age, race, and OM history. The average difference in MEE-CLI onsets was 1.2 +/- 4.0 days; approximately 32% of MEEs occurred prior to CLI onset and 17% on the same day as CLI onset. CLIs adversely affect the middle ear-ambient pressure balance and are frequently associated with MEE episodes. The distribution in onsets between those events suggests that chemoprophylaxis of a child with a newly identified CLI to prevent MEE would have a low expected efficiency.

  6. Acoustic inspection of concrete bridge decks

    NASA Astrophysics Data System (ADS)

    Henderson, Mark E.; Dion, Gary N.; Costley, R. Daniel

    1999-02-01

    The determination of concrete integrity, especially in concrete bridge decks, is of extreme importance. Current systems for testing concrete structures are expensive, slow, or tedious. State of the art systems use ground penetrating radar, but they have inherent problems especially with ghosting and signal signature overlap. The older method of locating delaminations in bridge decks involves either tapping on the surface with a hammer or metal rod, or dragging a chain-bar across the bridge deck. Both methods require a `calibrated' ear to determine the difference between good sections and bad sections of concrete. As a consequence, the method is highly subjective, different from person to person and even day to day for a given person. In addition, archival of such data is impractical, or at least improbable, in most situations. The Diagnostic Instrumentation and Analysis Laboratory has constructed an instrument that implements the chain-drag method of concrete inspection. The system is capable of real-time analysis of recorded signals, archival of processed data, and high-speed data acquisition so that post-processing of the data is possible for either research purposes or for listening to the recorded signals.

  7. An evaluation of a nurse-led ear care service in primary care: benefits and costs.

    PubMed Central

    Fall, M; Walters, S; Read, S; Deverill, M; Lutman, M; Milner, P; Rodgers, R

    1997-01-01

    BACKGROUND: Nurses trained in ear care provide a new model for the provision of services in general practice, with the aim of cost-effective treatment of minor ear and hearing problems that affect well-being and quality of life. AIM: To compare a prospective observational cohort study measuring health outcomes and resource use for patients with ear or hearing problems treated by nurses trained in ear care with similar patients treated by standard practice. METHOD: A total of 438 Rotherham and 196 Barnsley patients aged 16 years or over received two self-completion questionnaires: questionnaire 1 (Q1) on the day of consultation and questionnaire 2 (Q2) after three weeks. Primary measured outcomes were changes in discomfort and pain; secondary outcomes included the effect on normal life, health status, patient satisfaction, and resources used. RESULTS: After adjusting for differences at Q1, by Q2 there was no statistical evidence of a difference in discomfort and pain reduction, or differential change in health status between areas. Satisfaction with treatment was significantly higher (P = 0.0001) in Rotherham (91%) than in Barnsley (82%). Average total general practitioner (GP) consultations were lower in Rotherham at 0.4 per patient with an average cost of 6.28 Pounds compared with Barnsley at 1.4 per patient and an average cost of 22.53 Pounds (P = 0.04). Barnsley GPs prescribed more drugs per case (6% of total costs compared with 1.5%) and used more systemic antibiotics (P = 0.001). CONCLUSIONS: Nurses trained in ear care reduce costs, GP workload, and the use of systemic antibiotics, while increasing patient satisfaction with care. With understanding and support from GPs, such nurses are an example of how expanded nursing roles bring benefits to general practice. Nurses trained in ear care reduce treatment costs, reduce the use of antibiotics, educate patients in ear care, increase patient satisfaction, and raise ear awareness. PMID:9519514

  8. A comprehensive catalogue of the coding and non-coding transcripts of the human inner ear

    PubMed Central

    Corneveaux, Jason J.; Ohmen, Jeffrey; White, Cory; Allen, April N.; Lusis, Aldons J.; Van Camp, Guy; Huentelman, Matthew J.; Friedman, Rick A.

    2015-01-01

    The mammalian inner ear consists of the cochlea and the vestibular labyrinth (utricle, saccule, and semicircular canals), which participate in both hearing and balance. Proper development and life-long function of these structures involves a highly complex coordinated system of spatial and temporal gene expression. The characterization of the inner ear transcriptome is likely important for the functional study of auditory and vestibular components, yet, primarily due to tissue unavailability, detailed expression catalogues of the human inner ear remain largely incomplete. We report here, for the first time, comprehensive transcriptome characterization of the adult human cochlea, ampulla, saccule and utricle of the vestibule obtained from patients without hearing abnormalities. Using RNA-Seq, we measured the expression of >50,000 predicted genes corresponding to approximately 200,000 transcripts, in the adult inner ear and compared it to 32 other human tissues. First, we identified genes preferentially expressed in the inner ear, and unique either to the vestibule or cochlea. Next, we examined expression levels of specific groups of potentially interesting RNAs, such as genes implicated in hearing loss, long non-coding RNAs, pseudogenes and transcripts subject to nonsense mediated decay (NMD). We uncover the spatial specificity of expression of these RNAs in the hearing/balance system, and reveal evidence of tissue specific NMD. Lastly, we investigated the non-syndromic deafness loci to which no gene has been mapped, and narrow the list of potential candidates for each locus. These data represent the first high-resolution transcriptome catalogue of the adult human inner ear. A comprehensive identification of coding and non-coding RNAs in the inner ear will enable pathways of auditory and vestibular function to be further defined in the study of hearing and balance. Expression data are freely accessible at https://www.tgen.org/home/research/research-divisions/neurogenomics/supplementary-data/inner-ear-transcriptome.aspx PMID:26341477

  9. Otic Langerhans' Cell Histiocytosis in an Adult: A Case Report and Review of the Literature

    PubMed Central

    Gungadeen, Anil; Kullar, Peter; Yates, Philip

    2013-01-01

    Objective. To present a case of otic Langerhans' cell histiocytosis in an adult. Also included the diagnosis and management of the condition and a review of the relevant literature. Case Report. We report a case of a 41-year-old man with a history of persistent unilateral ear discharge associated with an aural polyp. Radiological imaging showed bony lesions of the skull and a soft-tissue mass within the middle ear. Histological analysis of the polyp demonstrated Langerhans' cell histiocytosis. His otological symptoms were completely resolved with the systemic therapy. Conclusions. Otic Langerhans' cell histiocytosis can present in adults. Persistent ear symptoms along with evidence of soft-tissue masses within the ear and bony lesions of the skull or elsewhere should prompt the otolaryngologists to include Langerhans' cell histiocytosis in their differential diagnosis. Management should be with systemic therapy rather than local surgical treatment. PMID:23762704

  10. The Role of Zic Genes in Inner Ear Development in the Mouse: Exploring Mutant Mouse Phenotypes

    PubMed Central

    Chervenak, Andrew P.; Bank, Lisa M.; Thomsen, Nicole; Glanville-Jones, Hannah C; Skibo, Jonathan; Millen, Kathleen J.; Arkell, Ruth M.; Barald, Kate F.

    2014-01-01

    Background Murine Zic genes (Zic1-5) are expressed in the dorsal hindbrain and in periotic mesenchyme (POM) adjacent to the developing inner ear. Zic genes are involved in developmental signaling pathways in many organ systems, including the ear, although their exact roles haven't been fully elucidated. This report examines the role of Zic1, Zic2, and Zic4 during inner ear development in mouse mutants in which these Zic genes are affected Results Zic1/Zic4 double mutants don't exhibit any apparent defects in inner ear morphology. By contrast, inner ears from Zic2kd/kd and Zic2Ku/Ku mutants have severe but variable morphological defects in endolymphatic duct/sac and semicircular canal formation and in cochlear extension in the inner ear. Analysis of otocyst patterning in the Zic2Ku/Ku mutants by in situ hybridization showed changes in the expression patterns of Gbx2 and Pax2. Conclusions The experiments provide the first genetic evidence that the Zic genes are required for morphogenesis of the inner ear. Zic2 loss-of-function doesn't prevent initial otocyst patterning but leads to molecular abnormalities concomitant with morphogenesis of the endolymphatic duct. Functional hearing deficits often accompany inner ear dysmorphologies, making Zic2 a novel candidate gene for ongoing efforts to identify the genetic basis of human hearing loss. PMID:25178196

  11. Operational Characteristics of Four Commercially Available Personal Cooling Vests

    NASA Technical Reports Server (NTRS)

    Ku, Yu-Tsuan E.; Montgomery, Leslie D.; Lee, Hank C.; Webbon, Bruce W.; Kliss, Mark (Technical Monitor)

    1997-01-01

    Personal thermoregulatory systems which provide chest cooling are used in the industrial and aerospace environments to alleviate thermal stress. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objectives of this study were to compare the effectiveness of two passive and two active cooling vests, and to measure the body temperature and circulatory changes produced by each cooling vest configuration. The MicroClimate Systems and the Life Enhancement Tech(LET) lightweight liquid cooling vests, the Steele Vest and LET's Zipper Front Garment were used to cool the chest region of 11 male and 10 female subjects (25 to 55 yr.) in this study. Calf, forearm and finger blood flows were measured using a tetrapolar impedance rheograph. The subjects, seated in an upright position at normal room temperature (approx.21 C), were tested for 60 min. with the cooling system operated at its maximum cooling capacity. Blood flows were recorded continuously using a computer data acquisition system with a sampling frequency of 250 Hz. Oral, right and left ear temperatures and cooling system parameters were logged manually every 5 min. Arm, leg, chest and rectal temperatures; heart rate; respiration; and an activity index were recorded continuously on a URI Inc. Biolog ambulatory monitor. In general, the male and female subjects' rectal and ear temperature responses to cooling were similar for all vest configurations tested. Oral temperatures during the recovery period were significantly (P<0.05) lower than during the control period, approx.0.2 - 0.5 C, for both men and women wearing any of the four different garments. The corresponding car temperatures were significantly (P<0.05) decreased approx.0.2 - 0.3 C by the end of the recovery period. Compared to the control period, no significant differences were found in rectal temperatures during cooling and recovery periods. These results show that all vest configurations elicit a similar thermal response in both male and female subject groups. However, subject population variance was rather large and may have masked differences between the vests. One vest may prove more effective than another for a given individual, and experience is the only means of determining this.

  12. Differences in the suppression of distortion product otoacoustic emissions by contralateral white noise between patients with acute or chronic tinnitus.

    PubMed

    Riga, Maria; Komis, Agis; Marangoudakis, Pavlos; Naxakis, Stefanos; Ferekidis, Eleftherios; Kandiloros, Dimitrios; Danielides, Vasilios

    2017-08-01

    The mechanisms underlying the shift from acute tinnitus to chronic remain obscure. An association between tinnitus and medial olivocochlear bundle (MOCB) reflex dysfunction has been hypothesised by several studies. The differences between participants with acute and chronic tinnitus have not yet been investigated. Participants were examined with distortion product otoacoustic emissions (DPOAEs) suppression elicited by contralateral white noise. They were compared in terms of frequency regions with non-recordable DPOAEs, suppression amplitudes and the presence of DPOAE enhancement. Eighteen participants with acute tinnitus, 40 age-matched adults with chronic tinnitus and 17 controls were included. All participants (aged 34.7 ± 9.6years; mean ± Standard deviation) had normal hearing. Tinnitus was bilateral in 22 participants and unilateral in 36. Ears with chronic tinnitus presented significantly lower DPOAE suppression amplitudes than ears with acute tinnitus (p < 0.0001). Both acute and chronic tinnitus ears present a high prevalence of enhancement, significantly different from controls (p < 0.0001, p = 0.0002, respectively). Non-recordable DPOAEs were significantly more frequent in the chronic than in the acute tinnitus and control groups (p < 0.0001). The differences between study groups indicate that when tinnitus becomes chronic, DPOAEs suppression presents changes that might reveal corresponding steps in tinnitus pathophysiology. Treatment implications are discussed.

  13. Comparison of non-invasive measures of cholinergic and allergic airway responsiveness in rats.

    PubMed

    Glaab, T; Hecker, H; Stephan, M; Baelder, R; Braun, A; Korolewitz, R; Krug, N; Hoymann, H G

    2006-04-01

    Non-invasive analysis of tidal expiratory flow parameters such as Tme/TE (time needed to reach peak expiratory flow divided by total expiratory time) or midexpiratory tidal flow (EF50) has been shown useful for phenotypic characterization of lung function in humans and animal models. In this study, we aimed to compare the utility of two non-invasive measures, EF50 and Tme/TE, to monitor bronchoconstriction to inhaled cholinergic and allergic challenges in Brown-Norway rats. Non-invasive measurements of Tme/TE and EF50 were paralleled by invasive recordings of Tme/TE, EF50 and pulmonary conductance (GL). First, dose-response studies with acetylcholine were performed in naive rats, showing that EF50 better than Tme/TE reflected the dose-related changes as observed with the classical invasive outcome parameter GL. The subsequent determination of allergen-specific early airway responsiveness (EAR) showed that ovalbumin-sensitized and -challenged rats exhibited airway inflammation and allergen-specific EAR. Again, EF50 was more sensitive than Tme/TE in detecting the allergen-specific EAR recorded with invasive and non-invasive lung function methods and agreed well with classical GL measurements. We conclude that non-invasive assessment of EF50 is significantly superior to Tme/TE and serves as a suitable and valid tool for phenotypic screening of cholinergic and allergic airway responsiveness in rats.

  14. Twenty-four hours or 10 days? A prospective randomised controlled trial in children comparing head bandages following pinnaplasty.

    PubMed

    Ramkumar, S; Narayanan, V; Laing, J H E

    2006-01-01

    The perceived benefits of bandaging for 10 days following pinnaplasty have been questioned by previous studies. The problems arising from these dressings are many [Powell BWEM. The value of head dressings in the postoperative management of the prominent ear. Br J Plast Surg 1989;42:692-4. Bartley J. How long should ears be bandaged after otoplasty? J Laryngol Otol 1998;112:531-2. Wong MC, Sylaidis P. Head dressings for pinnaplasty: a tradition not supported by evidence. Br J Plast Surg 2001;54:81-2], including their slippage [Powell BWEM. The value of head dressings in the postoperative management of the prominent ear. Br J Plast Surg 1989;42:692-4. Bradbury ET, Hewison J, Timmons MJ. Psychological and social outcome of prominent ear correction in children. Br J Plast Surg 1992;45:97-100. Jeffery SLA. Complications following correction of prominent ears: an audit review of 122 cases. Br J Plast Surg 1999;52:588-90]. Eighty children were recruited into a prospective randomised controlled trial comparing the use of a head bandage for only 24 h with a standard practise of a 10-day head bandage. A preoperative measurement of the lateral ear projection (LEP) was made. The outcome measures recorded during the two planned postoperative visits at 10 days (visit 1) and 2 months (visit 2) were: patient satisfaction score, LEP, complications and any unscheduled hospital visits associated with the surgery. There was no significant difference in LEP and patient satisfaction between the two groups at both the scheduled postoperative visits. Differences between the groups in the number of unscheduled visits (p=0.21) did not reach statistical significance. The findings indicate that it is safe and effective to use head bandage for only 24 h following surgical correction of prominent ears. This study shows no benefit from the application of a formal head bandage for any longer than 1 day.

  15. Sensorineural hearing loss in patients with chronic suppurative otitis media: Is there a significant correlation?

    PubMed

    Amali, Amin; Hosseinzadeh, Nima; Samadi, Shahram; Nasiri, Shirin; Zebardast, Jayran

    2017-02-01

    Hearing loss as a sequel of chronic suppurative otitis media (CSOM) is often conductive, but recent studies have found an additional sensorineural component in these patients, thus demonstrating inner ear damage. The aim of the study was to determine the association between CSOM and sensorineural hearing loss (SNHL) and to assess the influence of patient's age, duration of disease, and presence of cholesteatoma and ossicular erosion on the degree of SNHL. In a retrospective study, the medical records of 119 patients who underwent surgery was reviewed. Seventy patients met the inclusion criteria of unilateral otorrhea, normal contralateral ear on otoscopy, and age between 10-65 years with no history of head trauma or ear surgery or familial hearing loss. Bone conduction (BC) thresholds for affected and contralateral ear were measured at frequencies of 500, 1000, 2000, and 4000 Hz. Data analysis was performed using SPSS 13 with independent-samples t-test, Pearson correlation test, and two-tailed analysis. A p ≤ 0.05 was considered statistically significant. Significant higher BC thresholds were found in the affected ear than in the normal ear for each frequency (p < 0.001), which increased with increasing frequency (7.00 dB at the 500 Hz and 9.71 dB at the 4000 Hz). There was a significant correlation between age and degree of SNHL (r = 0.422, p < 0.001) but no significant correlation was in duration of the disease (r = 0.119, p > 0.05). There was no relationship between presence of cholesteatoma and ossicular erosion with SNHL (p > 0.05). These findings demonstrate that CSOM is associated with some degree of SNHL and cochlear damage, and higher frequencies are more affected. Aging can act as a precipitating factor in this pathological process.

  16. Effect of laryngoscopy on middle ear pressure during anaesthesia induction.

    PubMed

    Degerli, Semih; Acar, Baran; Sahap, Mehmet; Horasanlı, Eyup

    2013-01-01

    The procedure of laryngoscopic orotracheal intubation (LOTI) has many impacts on several parts of the body. But its effect on middle ear pressure (MEP) is not known well. The purpose of this study is to evaluate the MEP changes subsequent to insertion of endotracheal tube with laryngoscope. 44 patients were included in this study with a normal physical examination of ear, nose and throat. A standard general anaesthesia induction without any inhaler agent was performed to the all patients. The MEP measurements for both ears were applied under 1 minute; before induction (BI) and after intubation (AI) with a middle ear analyzer. Also hemodynamic parameters were recorded before induction and after intubation. Of the 44 patients were 25 women and 19 men with a 43.5±15.1 mean age. A statistically significant rise in MEP was seen in all patients subsequent to insertion of endotracheal tube (P<0.05). Mean right MEPs were BI: -9.5 and AI: 18.5 daPa. Also mean left MEPs were BI: -21.7 and AI: 29.1 daPa. The amount of increases in left and right MEPs were 50 daPa and 27 daPa, respectively. 20% increase in systolic blood pressure and 19% increase in diastolic blood pressure were determined after intubation. The mean heart rate was 76/min before intubation, whereas it was 102/min after intubation with a 34% increase. In this study bilateral significant increases in MEP were determined subsequent to LOTI. Possible factors affecting MEP may be auditory tube, size and type of the blades, drugs and face masking time. But on the other hand in our opinion cardiovascular and haemodynamic response to LOTI has the most impact over the middle ear mucosa with mucosal venous congestion.

  17. Experimental and theoretical identification of a four- acoustic-inputs/two-vibration-outputs hearing system

    NASA Astrophysics Data System (ADS)

    Balaji, P. A.

    1999-07-01

    A cricket's ear is a directional acoustic sensor. It has a remarkable level of sensitivity to the direction of sound propagation in a narrow frequency bandwidth of 4-5 KHz. Because of its complexity, the directional sensitivity has long intrigued researchers. The cricket's ear is a four-acoustic-inputs/two-vibration-outputs system. In this dissertation, this system is examined in depth, both experimentally and theoretically, with a primary goal to understand the mechanics involved in directional hearing. Experimental identification of the system is done by using random signal processing techniques. Theoretical identification of the system is accomplished by analyzing sound transmission through complex trachea of the ear. Finally, a description of how the cricket achieves directional hearing sensitivity is proposed. The fundamental principle involved in directional heating of the cricket has been utilized to design a device to obtain a directional signal from non- directional inputs.

  18. Popularity and Harms of Aural Foreign Bodies: A Descriptive Study of Patients in Baqiyatallah University Hospital, Tehran, Iran.

    PubMed

    Taheri, Abolfazl; Mehmandari, Sina Navaei; Shahidi, Mojtaba; Mehdizadeh, Hamidreza; Mirlohi, Seyyed Mohammad Javad; Aref, Nasrin Mohammadi; Avanaki, Mahsa Alborzi; Khosravi, Mohammad Hossein

    2017-12-01

    To evaluate the prevalence of external ear complications among Iranian aural foreign body users attending to otolaryngology clinic of our hospital. In this cross-sectional study patients attending to Otolaryngology clinics of Baqiyatallah hospital were enrolled regardless of their age, gender and reason of attending. Patients between 15 and 60 years of age were included in the present study. Those with positive history of chronic ear diseases, ear surgery, congenital ear disorders, trauma to ear or head and neck region or shock wave trauma were excluded from the study. Demographic information as well as data on chief complaint, educational level, frequency and type of used foreign body and findings of physical examination and Otoscopy by a single otolaryngologist were recorded in a predesigned checklist. Eventually 362 patients (232 male and 130 female) with a mean age of 40.32 ± 16.90 years underwent analysis. Of all patients 244 (67.2%) were using a kind of aural foreign body frequently and Cotton bud was the most popular (63.5%) used foreign body among patients. Drying ear canal was the most common (54.9%) reason of using AFBs among study individuals followed by itching (29.5%) and pyorrhea (11.06%). Also 11 (4.5%) patients were using AFBs as a habit with no specific reason. Itching was the most prevalent symptom reported by both aural foreign body users (78%) and non-users (45.5%); however it was significantly higher among AFB users (p = 0.026). Also hearing loss was significantly more reported by AFB users (p = 0.033). A majority of patients had normal physical examination in both AFB users and non-users group. Inflammation of ear canal was significantly more detected in AFB users (p = 0.004). In addition, rate of right ear wax impaction was higher among AFB users (p = 0.016). In conclusion we realized that 67.2% of patients attending to Otolaryngology clinic of our hospital were using a kind of aural foreign bodies and itching was the most common chief complaint of these patients.

  19. Analysis of subtle auditory dysfunctions in young normal-hearing subjects affected by Williams syndrome.

    PubMed

    Paglialonga, Alessia; Barozzi, Stefania; Brambilla, Daniele; Soi, Daniela; Cesarani, Antonio; Spreafico, Emanuela; Tognola, Gabriella

    2014-11-01

    To assess if young subjects affected by Williams syndrome (WS) with normal middle ear functionality and normal hearing thresholds might have subtle auditory dysfunctions that could be detected by using clinically available measurements. Otoscopy, acoustic reflexes, tympanometry, pure-tone audiometry, and distortion product otoacoustic emissions (DPOAEs) were measured in a group of 13 WS subjects and in 13 age-matched, typically developing control subjects. Participants were required to have normal otoscopy, A-type tympanogram, normal acoustic reflex thresholds, and pure-tone thresholds≤15 dB HL at 0.5, 1, and 2 kHz bilaterally. To limit the possible influence of middle ear status on DPOAE recordings, we analyzed only data from ears with pure-tone thresholds≤15 dB HL across all octave frequencies in the range 0.25-8 kHz, middle ear pressure (MEP)>-50 daPa, static compliance (SC) in the range 0.3-1.2 cm3, and ear canal volume (ECV) in the range 0.2-2 ml, and we performed analysis of covariance to remove the possible effects of middle ear variables on DPOAEs. No differences in mean hearing thresholds, SC, ECV, and gradient were observed between the two groups, whereas significantly lower MEP values were found in WS subjects as well as significantly decreased DPOAEs up to 3.2 kHz after adjusting for differences in middle ear status. Results revealed that WS subjects with normal hearing thresholds (≤15 dB HL) and normal middle ear functionality (MEP>-50 daPa, SC in the range 0.3-1.2 cm3, ECV in the range 0.2-2 ml) might have subtle auditory dysfunctions that can be detected by using clinically available methods. Overall, this study points out the importance of using otoacoustic emissions as a complement to routine audiological examinations in individuals with WS to detect, before the onset of hearing loss, possible subtle auditory dysfunctions so that patients can be early identified, better monitored, and promptly treated. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  20. When avoidance leads to approach: how ear preference interacts with neuroticism to predict disinhibited approach.

    PubMed

    Jackson, Chris J

    2008-07-01

    A series of eight studies focuses on how the avoidance system represented by neuroticism can lead to disinhibited approach tendencies. Based on research which argues that hemispheric preferences predispose the left hemisphere to fast action goal formation, and contralateral pathways between ear and brain, it is proposed that (a) people with a right ear preference will engage in fast action goal formation and (b) disinhibited approach results from neurotic people who reduce anxiety by means of fast action goal formation. Study 1 provides evidence from telesales operators of a link between self-rated ear preference and objective ear preference and provides evidence that disinhibited approach is predicted by a neuroticismxear preference interaction. Studies 2, 3, and 4 provide evidence that ear preference is related to other measures of objective aural preference and action goal formation. Studies 5, 6, 7, and 8 provide evidence that the neuroticismxear preference interaction predicts a variety of different disinhibited approach tendencies.

  1. The influence of periodic wind turbine noise on infrasound array measurements

    NASA Astrophysics Data System (ADS)

    Pilger, Christoph; Ceranna, Lars

    2017-02-01

    Aerodynamic noise emissions from the continuously growing number of wind turbines in Germany are creating increasing problems for infrasound recording systems. These systems are equipped with highly sensitive micro pressure sensors accurately measuring acoustic signals in a frequency range inaudible to the human ear. Ten years of data (2006-2015) from the infrasound array IGADE in Northern Germany are analysed to quantify the influence of wind turbine noise on infrasound recordings. Furthermore, a theoretical model is derived and validated by a field experiment with mobile micro-barometer stations. Fieldwork was carried out 2004 to measure the infrasonic pressure level of a single horizontal-axis wind turbine and to extrapolate the sound effect for a larger number of nearby wind turbines. The model estimates the generated sound pressure level of wind turbines and thus enables for specifying the minimum allowable distance between wind turbines and infrasound stations for undisturbed recording. This aspect is particularly important to guarantee the monitoring performance of the German infrasound stations I26DE in the Bavarian Forest and I27DE in Antarctica. These stations are part of the International Monitoring System (IMS) verifying compliance with the Comprehensive Nuclear-Test-Ban Treaty (CTBT), and thus have to meet stringent specifications with respect to infrasonic background noise.

  2. Development of a novel clinical scoring system for on-farm diagnosis of bovine respiratory disease in pre-weaned dairy calves.

    PubMed

    Love, William J; Lehenbauer, Terry W; Kass, Philip H; Van Eenennaam, Alison L; Aly, Sharif S

    2014-01-01

    Several clinical scoring systems for diagnosis of bovine respiratory disease (BRD) in calves have been proposed. However, such systems were based on subjective judgment, rather than statistical methods, to weight scores. Data from a pair-matched case-control study on a California calf raising facility was used to develop three novel scoring systems to diagnose BRD in preweaned dairy calves. Disease status was assigned using both clinical signs and diagnostic test results for BRD-associated pathogens. Regression coefficients were used to weight score values. The systems presented use nasal and ocular discharge, rectal temperature, ear and head carriage, coughing, and respiratory quality as predictors. The systems developed in this research utilize fewer severity categories of clinical signs, require less calf handling, and had excellent agreement (Kappa > 0.8) when compared to an earlier scoring system. The first scoring system dichotomized all clinical predictors but required inducing a cough. The second scoring system removed induced cough as a clinical abnormality but required distinguishing between three levels of nasal discharge severity. The third system removed induced cough and forced a dichotomized variable for nasal discharge. The first system presented in this study used the following predictors and assigned values: coughing (induced or spontaneous coughing, 2 points), nasal discharge (any discharge, 3 points), ocular discharge (any discharge, 2 points), ear and head carriage (ear droop or head tilt, 5 points), fever (≥39.2°C or 102.5°F, 2 points), and respiratory quality (abnormal respiration, 2 points). Calves were categorized "BRD positive" if their total score was ≥4. This system correctly classified 95.4% cases and 88.6% controls. The second presented system categorized the predictors and assigned weights as follows: coughing (spontaneous only, 2 points), mild nasal discharge (unilateral, serous, or watery discharge, 3 points), moderate to severe nasal discharge (bilateral, cloudy, mucoid, mucopurlent, or copious discharge, 5 points), ocular discharge (any discharge, 1 point), ear and head carriage (ear droop or head tilt, 5 points), fever (≥39.2°C, 2 points), and respiratory quality (abnormal respiration, 2 points). Calves were categorized "BRD positive" if their total score was ≥4. This system correctly classified 89.3% cases and 92.8% controls. The third presented system used the following predictors and scores: coughing (spontaneous only, 2 points), nasal discharge (any, 4 points), ocular discharge (any, 2 points), ear and head carriage (ear droop or head tilt, 5 points), fever (≥39.2°C, 2 points), and respiratory quality (abnormal respiration, 2 points). Calves were categorized "BRD positive" if their total score was ≥5. This system correctly classified 89.4% cases and 90.8% controls. Each of the proposed systems offer few levels of clinical signs and data-based weights for on-farm diagnosis of BRD in dairy calves.

  3. Development of a novel clinical scoring system for on-farm diagnosis of bovine respiratory disease in pre-weaned dairy calves

    PubMed Central

    Love, William J.; Lehenbauer, Terry W.; Kass, Philip H.; Van Eenennaam, Alison L.

    2014-01-01

    Several clinical scoring systems for diagnosis of bovine respiratory disease (BRD) in calves have been proposed. However, such systems were based on subjective judgment, rather than statistical methods, to weight scores. Data from a pair-matched case-control study on a California calf raising facility was used to develop three novel scoring systems to diagnose BRD in preweaned dairy calves. Disease status was assigned using both clinical signs and diagnostic test results for BRD-associated pathogens. Regression coefficients were used to weight score values. The systems presented use nasal and ocular discharge, rectal temperature, ear and head carriage, coughing, and respiratory quality as predictors. The systems developed in this research utilize fewer severity categories of clinical signs, require less calf handling, and had excellent agreement (Kappa > 0.8) when compared to an earlier scoring system. The first scoring system dichotomized all clinical predictors but required inducing a cough. The second scoring system removed induced cough as a clinical abnormality but required distinguishing between three levels of nasal discharge severity. The third system removed induced cough and forced a dichotomized variable for nasal discharge. The first system presented in this study used the following predictors and assigned values: coughing (induced or spontaneous coughing, 2 points), nasal discharge (any discharge, 3 points), ocular discharge (any discharge, 2 points), ear and head carriage (ear droop or head tilt, 5 points), fever (≥39.2°C or 102.5°F, 2 points), and respiratory quality (abnormal respiration, 2 points). Calves were categorized “BRD positive” if their total score was ≥4. This system correctly classified 95.4% cases and 88.6% controls. The second presented system categorized the predictors and assigned weights as follows: coughing (spontaneous only, 2 points), mild nasal discharge (unilateral, serous, or watery discharge, 3 points), moderate to severe nasal discharge (bilateral, cloudy, mucoid, mucopurlent, or copious discharge, 5 points), ocular discharge (any discharge, 1 point), ear and head carriage (ear droop or head tilt, 5 points), fever (≥39.2°C, 2 points), and respiratory quality (abnormal respiration, 2 points). Calves were categorized “BRD positive” if their total score was ≥4. This system correctly classified 89.3% cases and 92.8% controls. The third presented system used the following predictors and scores: coughing (spontaneous only, 2 points), nasal discharge (any, 4 points), ocular discharge (any, 2 points), ear and head carriage (ear droop or head tilt, 5 points), fever (≥39.2°C, 2 points), and respiratory quality (abnormal respiration, 2 points). Calves were categorized “BRD positive” if their total score was ≥5. This system correctly classified 89.4% cases and 90.8% controls. Each of the proposed systems offer few levels of clinical signs and data-based weights for on-farm diagnosis of BRD in dairy calves. PMID:24482759

  4. Otolaryngological Presentations in Times of Terror: Profile from a Tertiary Health Center in North-Central Nigeria

    PubMed Central

    Adoga, Adeyi A.; Kokong, Daniel D.; Ozoilo, Kenneth N.

    2017-01-01

    Objectives: To report the incidence, socio-demographic characteristics, otorhinolaryngological presentations and outcomes of management of patients at the Jos University Teaching Hospital following terror attacks. Methods: A prospective descriptive hospital based study of consecutive patients presenting with ear, nose and throat injuries as a result of bomb blasts and ethno-religious crises within a six-year period and managed at the Jos University Teaching Hospital were studied for age, gender, ear, nose and throat presentations, injury mechanism, interventions and outcome of interventions. A designed proforma was used for data collection. Results: There were 107 ear, nose and throat injuries from a total 468 terror-related injuries consisting of 66 (61.7%) males and 41 (38.3%) females (M:F ratio of 1.6:1), aged between 5 and 77 years (mean= 36.7 years; SD= +/- 16.2). Two peak age incidences of injuries in the first and third decades were recorded. The commonest source of injuries was bomb blasts in 47 (44%) patients. Multiple facial fractures with soft tissue injuries were the commonest seen in 78 (72.9%) patients. The commonest associated injuries were head injuries (n= 36). Ninety-four (87.9%) patients presented via the Accident and Emergency department, 16 (15%) received pre-hospital care. Patients with multiple injuries stayed longer in the hospital (p-value= 0.028). Complications were recorded in 19 (17.8%) patients. A case fatality rate of 5.6% was recorded. Conclusion: Bomb blasts were the major form of terror attacks in our region. The presence of multiple injuries is a significant negative predictor of patient outcomes. PMID:28795066

  5. Assessment of Impulse Noise Level and Acoustic Trauma in Military Personnel

    PubMed Central

    Rezaee, Maryam; Mojtahed, Mohammad; Ghasemi, Mohammad; Saedi, Babak

    2012-01-01

    Background: Military personnel are usually exposed to high levels of impulse noise (IN) which can lead to hearing loss. Objectives: The purpose of this study was to assess the effects of relatively low level exposure of impulse noise (IN) during shooting practice on hearing using pure tone audiometry (PTA) and transiently evoked otoacoustic emission (TEOAE) in military personnel. Materials and Methods: Forty male soldiers (mean age 20.08 years) were recruited for the study. Prior to their first shooting practice, PTA and TEOAE were recorded. After 15 minutes and one week post- practice PTA and TEOAE were compared. Results: Immediately after shooting practice significant differences in PTA at 500, 1000, and 4000 Hz were observed for the right ear and no significant difference at any frequency for the left ear. There was a significant difference in the amplitude of TEOAE 15 minutes after shooting practice at 500, 1000, 2000, 3000, and 4000 Hz in the right ear, while for the left ear the difference was significant at 1000 and 2000 Hz. One week after exposure a significant difference at 500 and 4000 Hz was found only in the right ear and a significant difference in the amplitude of TEOAE was observed at 500, 1000, 2000, 3000, and 4000 Hz. Conclusions: Even exposure lower than permissible levels may lead to acoustic trauma. TEOAE is more sensitive than PTA in detecting early hearing loss after military shooting exercises. Hearing protection equipment and appropriate surveillance programs are recommended. PMID:24749098

  6. Middle ear findings and need for ventilation tubes among pediatric cleft lip and palate patients in northern Finland.

    PubMed

    Lehtonen, Ville; Lithovius, Riitta H; Autio, Timo J; Sándor, George K; Ylikontiola, Leena P; Harila, Virpi; Pesonen, Paula; Koskinen, Sari; Anttonen, Vuokko

    2016-04-01

    Middle ear problems are common in cleft patients. This study aimed to determine the need for ventilation tubes (VTs) and complications such as tympanic perforation and cholesteatoma. Data of 156 children with clefts managed in northern Finland spanning 15 years from 1997 to 2011 were collected from 6 hospitals. The following were recorded: birth date, gender, cleft type, surgery timing, surgery type, number of tube insertions, tube material, middle ear findings, and tube placement timing. Clefts were divided into 4 groups: cleft palate (CP), cleft lip and palate (CLP), cleft lip (CL), and submucous cleft palate. The prevalence of middle ear findings was reported. Mucous secretion was noted in 96.8% of CLP patients, 69.2% of CP patients, and 13.0% of CL patients. In all, 82.7% of study group had 1 or more VTs placed during follow-up. All CLP patients required more than 1 VT placement. A total of 94.5% of CP patients required VTs compared to 13.0% of CL patients. In the presence of residual oral nasal fistula, the mean number of tube insertions was 5.3. The prevalence of tympanic perforations in clefts was 35.9% and cholesteatoma in 2.6% of patients. CLP and isolated CP patients have frequent middle ear infections requiring multiple VT placements. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  7. Why Cannot We have an Etiological Classification for the Patients with Granular Myringitis?

    PubMed

    Bansal, Mohan

    2017-09-01

    Though granular myringitis (GM) is not a very rare disease it does not have any classification. Its exact etiology is not known. The granulations on tympanic membrane also occur in association with other lesions of external auditory canal (EAC) and middle ear. The aims of this study were to know the etiological factors of GM and classify the disease according to its etiological factors and associated disorders of EAC and middle ear. Data were retrieved from the search of four electronic databases: PubMed, EMBASE, Cochrane Library, and Google scholar. Relevant articles were also sought by a hand search review of reference books. The databases were searched using the key words otitis externa, external otitis, granular myringitis, granular otitis externa and myringitis. Data were extracted using a pre-defined data-extraction form. The following data were recorded (1) etiological and predisposing conditions; (2) pathological features; (3) associated disorders of external and middle ear. The study proposes the etiological classification of GM. It suggests two major groups: primary and secondary. The primary GM is basically idiopathic and these patients do no have evidences of any other types of otitis media and otitis externa. In the secondary GM the cause is obvious and the patients usually have associated otitis media and/or lesions of external ear canal. Author speculates that habit of self ear cleaning/scratching is a specific etiological factor in cases of primary GM but more studies are required to confirm this theory.

  8. Neural Representation of Scale Illusion: Magnetoencephalographic Study on the Auditory Illusion Induced by Distinctive Tone Sequences in the Two Ears

    PubMed Central

    Kuriki, Shinya; Yokosawa, Koichi; Takahashi, Makoto

    2013-01-01

    The auditory illusory perception “scale illusion” occurs when a tone of ascending scale is presented in one ear, a tone of descending scale is presented simultaneously in the other ear, and vice versa. Most listeners hear illusory percepts of smooth pitch contours of the higher half of the scale in the right ear and the lower half in the left ear. Little is known about neural processes underlying the scale illusion. In this magnetoencephalographic study, we recorded steady-state responses to amplitude-modulated short tones having illusion-inducing pitch sequences, where the sound level of the modulated tones was manipulated to decrease monotonically with increase in pitch. The steady-state responses were decomposed into right- and left-sound components by means of separate modulation frequencies. It was found that the time course of the magnitude of response components of illusion-perceiving listeners was significantly correlated with smooth pitch contour of illusory percepts and that the time course of response components of stimulus-perceiving listeners was significantly correlated with discontinuous pitch contour of stimulus percepts in addition to the contour of illusory percepts. The results suggest that the percept of illusory pitch sequence was represented in the neural activity in or near the primary auditory cortex, i.e., the site of generation of auditory steady-state response, and that perception of scale illusion is maintained by automatic low-level processing. PMID:24086676

  9. The Use of Temporoparietal Fascial Flap to Eliminate Wound Breakdown in Subtotal Petrosectomy for Chronic Discharging Ears.

    PubMed

    Yung, Matthew

    2016-03-01

    To find out if the use of the vascularized temporo-parietal fascial flap (TPFF) reduces postoperative infection or wound breakdown in subtotal petrosectomy for chronic discharging ears. A retrospective review on 26 subtotal petrosectomies with blind pit closures on chronic discharging ears performed by a single surgeon between 2000 and 2015 was performed. All patients had a minimum follow-up period of 6 months. Eleven mastoid cavities were obliterated with abdominal fat, and 15 cavities were obliterated with TPFF. There was no concomitant cochlear implant or middle ear implant. All postoperative wound infections or delay in wound healing were recorded into a database. The complication rates of the fat obliteration group were compared using Fisher's exact test with those for the TPFF obliteration group. In the fat obliteration group, 4 out of 11 patients had documented postoperative complications. Three had wound breakdown with exposure of the fat that required revision surgery. Another patient had postauricular abscess without the wound actually broken down. On the other hand, all the ears in the TPFF obliteration group (100%) were completely free of wound infection, wound breakdown, or any complication. The difference between the two groups was statistically significant (p = 0.022). Many authors have encountered postoperative infection or wound breakdown in subtotal petrosectomy with fat obliteration in the treatment of chronic otitis media. Using a richly vascularized temporo-temporal fascial flap to protect the blind pit closure in such patients reduces postoperative infection and wound breakdown.

  10. Identification of Adeno-Associated Viral Vectors That Target Neonatal and Adult Mammalian Inner Ear Cell Subtypes

    PubMed Central

    Shu, Yilai; Tao, Yong; Wang, Zhengmin; Tang, Yong; Li, Huawei; Dai, Pu; Gao, Guangping; Chen, Zheng-Yi

    2016-01-01

    The mammalian inner ear consists of diverse cell types with important functions. Gene mutations in these diverse cell types have been found to underlie different forms of genetic hearing loss. Targeting these mutations for gene therapy development represents a future therapeutic strategy to treat hearing loss. Adeno-associated viral (AAV) vectors have become the vector of choice for gene delivery in animal models in vivo. To identify AAV vectors that target inner ear cell subtypes, we systemically screened 12 AAV vectors with different serotypes (AAV1, 2, 5, 6, 6.2, 7, 8, 9, rh.8, rh.10, rh.39, and rh.43) that carry a reporter gene GFP in neonatal and adult mice by microinjection in vivo. We found that most AAVs infect both neonatal and adult inner ear, with different specificities and expression levels. The inner ear cochlear sensory epithelial region, which includes auditory hair cells and supporting cells, is most frequently targeted for gene delivery. Expression of the transgene is sustained, and neonatal inner ear delivery does not adversely affect hearing. Adult inner ear injection of AAV has a similar infection pattern as the younger inner ear, with the exception that outer hair cell death caused by the injection procedure can lead to hearing loss. In the adult, more so than in the neonatal mice, cell types infected and efficiency of infection are correlated with the site of injection. Most infected cells survive in neonatal and adult inner ears. The study adds to the list of AAV vectors that transduce the mammalian inner ear efficiently, providing the tools that are important to study inner ear gene function and for the development of gene therapy to treat hearing loss. PMID:27342665

  11. Geochemical Insights Into Lithospheric Melting and Instability in the Bufumbira Volcanic Field of the Western Rift, Uganda

    NASA Astrophysics Data System (ADS)

    Pitcavage, E.; Furman, T.; Nelson, W. R.

    2016-12-01

    The East African Rift System (EARS) is the earth's largest continental divergent boundary and is an unparalleled natural laboratory for understanding magmatic processes related to continental rifting. A fundamental unresolved question in EARS magmatism is the degree to which volcanism and rifting are influenced by Cenozoic plume-related melting rather than older, tectonically-driven metasomatism. In the latter scenario, metasomatism by carbonatite or silicate magmas and/or fluids that accompanies tectonic events such as the Proterozoic Pan-African Orogeny will create geochemical heterogeneities and rheological weaknesses in the sub-continental lithospheric mantle (SCLM). In the Western Rift, abundant alkaline mafic lavas record significant contributions from metasomatized SCLM. Modification, destabilization and foundering of metasomatized SCLM has an increasingly recognized role in continental magmatism worldwide. Lithospheric drip magmatism occurs when foundered lithosphere devolatilizes and melts on descent. Lithospheric thinning is one consequence of this process, and may play a role in physical aspects of rifting. Geochemical and geophysical evidence that drip magmatism has occurred in several areas of the EARS, including Turkana, Chyulu Hills, and Oligocene HT2 flood basalts in Afar, suggests that this process is fundamentally related to the onset of successful rifting. We use geochemical characteristics of primitive lavas from the Bufumbira volcanic field in the Western Rift's Virunga Province to demonstrate that ancient, tectonically-driven metasomatism modified the SCLM and contributes to recent volcanism. Further, we identify geochemical signatures which indicate that lithospheric drip melting is the primary petrogenetic process generating these lavas. Sr-Nd-Pb-Hf isotopic data show that the northern portion of the Western Rift, including Bufumbira, requires magma sources distinct from the rest of the EARS. Trace element data show that Bufumbira lavas are derived from depths within the garnet stability field and that source mineralogy includes phlogopite with potential amphibole and zircon; and that extent of melting increased with depth of melting, a signature of lithospheric drip.

  12. Evolution of the vestibulo-ocular system

    NASA Technical Reports Server (NTRS)

    Fritzsch, B.

    1998-01-01

    The evolutionary and developmental changes in the eye muscle innervation, the inner ear, and the vestibulo-ocular reflex are examined. Three eye muscle patterns, based on the innervation by distinct ocular motoneurons populations, can be identified: a lamprey, an elasmobranch, and a bony fish/tetrapod pattern. Four distinct patterns of variation in the vestibular system are described: a hagfish pattern, a lamprey pattern, an elasmobranch pattern, and a bony fish/tetrapod pattern. Developmental data suggest an influence of the hindbrain on ear pattern formation, thus potentially allowing a concomitant change of eye muscle innervation and ear variation. The connections between the ear and the vestibular nuclei and between the vestibular nuclei and ocular motoneurons are reviewed, and the role of neurotrophins for pattern specification is discussed. Three patterns are recognized in central projections: a hagfish pattern, a lamprey pattern, and a pattern for jawed vertebrates. Second-order connections show both similarities and differences between distantly related species such as lampreys and mammals. For example, elasmobranchs lack an internuclear system, which is at best poorly developed in lampreys. It is suggested that the vestibulo-ocular system shows only a limited degree of variation because of the pronounced functional constraints imposed on it.

  13. The comparative anatomy of the pig middle ear cavity: a model for middle ear inflammation in the human?

    PubMed Central

    PRACY, J. P.; WHITE, A.; MUSTAFA, Y.; SMITH, D.; PERRY, M. E.

    1998-01-01

    This study was undertaken to develop a functional model of otitis media with effusion (OME) in the pig (Sus scrofa), with the purpose of investigating the origin of lymphocytes populating the middle ear during the course of an inflammatory process. The relevance of the model to the human condition of OME is to a large extent dependent on the anatomical and physiological similarities between the middle ear cavity and the pharyngeal lymphoid tissue of the pig and man. Anatomical specimens were collected from 7 young Large White pigs to determine the gross anatomy of the middle ear cavity and the histological characteristics of the middle ear mucosa. It was found that the anatomy of the 3 parts of the middle ear cavity in man and in the pig is broadly similar, although some minor differences were observed. The porcine eustachian tube was seen to be cartilaginous throughout its length in contrast to the part osseous, part cartilaginous structure found in man; the porcine ossicles were slightly different in shape to those of man and the air cell system was situated inferior to the tympanic cavity in the pig as opposed to posteriorly in man. This paper describes the structure and morphology of the pig middle ear cavity and compares and contrasts it with that of man. The minor differences observed are of anatomical importance but do not diminish the usefulness of the pig middle ear cleft as a potential model for human middle ear disorders. PMID:9688502

  14. Phylogenetic distribution and expression of a penicillin-binding protein homologue, Ear and its significance in virulence of Staphylococcus aureus.

    PubMed

    Singh, Vineet K; Ring, Robert P; Aswani, Vijay; Stemper, Mary E; Kislow, Jennifer; Ye, Zhan; Shukla, Sanjay K

    2017-12-01

    Staphylococcus aureus is an opportunistic human pathogen that can cause serious infections in humans. A plethora of known and putative virulence factors are produced by staphylococci that collectively orchestrate pathogenesis. Ear protein (Escherichia coli ampicillin resistance) in S. aureus is an exoprotein in COL strain, predicted to be a superantigen, and speculated to play roles in antibiotic resistance and virulence. The goal of this study was to determine if expression of ear is modulated by single nucleotide polymorphisms in its promoter and coding sequences and whether this gene plays roles in antibiotic resistance and virulence. Promoter, coding sequences and expression of the ear gene in clinical and carriage S. aureus strains with distinct genetic backgrounds were analysed. The JE2 strain and its isogenic ear mutant were used in a systemic infection mouse model to determine the competiveness of the ear mutant.Results/Key findings. The ear gene showed a variable expression, with USA300FPR3757 showing a high-level expression compared to many of the other strains tested including some showing negligible expression. Higher expression was associated with agr type 1 but not correlated with phylogenetic relatedness of the ear gene based upon single nucleotide polymorphisms in the promoter or coding regions suggesting a complex regulation. An isogenic JE2 (USA300 background) ear mutant showed no significant difference in its growth, antibiotic susceptibility or virulence in a mouse model. Our data suggests that despite being highly expressed in a USA300 genetic background, Ear is not a significant contributor to virulence in that strain.

  15. Possibilities to use tank-mix adjuvants for better fungicide spreading on triticale ears.

    PubMed

    Ryckaert, Bert; Spanoghe, Pieter; Heremans, Betty; Haesaert, Geert; Steurbaut, Walter

    2008-09-10

    Tank-mix adjuvants can increase the overall performance of plant protection products. Their most important ways of action are the improved retention, spreading, wetting, and penetration of the pesticide on the target and the reduction of fine droplets. In this paper, deposition and spreading of the systemic fungicide propiconazole on triticale ears were quantified. A better deposition and spreading of fungicide on the ear may be a possible help for the Fusarium problem in triticale, wheat, and other cereals. Triticale ears were applied with propiconazole in combination with 11 different tank-mix adjuvants. Vegetable oil, alcohol ethoxylates, lactate ester, trisiloxanes, and an amphoteric molecule were included in this experiment. When no tank-mix adjuvant was used, the lower part of the ear was reached five times less by the propiconazole spray than the upper part of the ear. When the tank-mix adjuvant was combined with the propiconazole formulation, an increase in residue on both the upper and the lower part of the ear was observed. A higher residue on the upper half of the ear means a better deposition, while a higher residue on the lower part of the ear is related to a better downward spreading over the grains and the needles of the ear. The combination of those two observations makes it interesting to use tank-mix adjuvants for the prevention of mycotoxin-producing Fusarium species. The advantages are emphasized even more when cost effectiveness was calculated. The use of a proper tank-mix adjuvant can result in 40% lower cost per application per hectare.

  16. Binaural frequency selectivity in humans.

    PubMed

    Verhey, Jesko L; van de Par, Steven

    2018-01-23

    Several behavioural studies in humans have shown that listening to sounds with two ears that is binaural hearing, provides the human auditory system with extra information on the sound source that is not available when sounds are only perceived through one ear that is monaurally. Binaural processing involves the analysis of phase and level differences between the two ear signals. As monaural cochlea processing (in each ear) precedes the neural stages responsible for binaural processing properties it is reasonable to assume that properties of the cochlea may also be observed in binaural processing. A main characteristic of cochlea processing is its frequency selectivity. In psychoacoustics, there is an ongoing discussion on the frequency selectivity of the binaural auditory system. While some psychoacoustic experiments seem to indicate poorer frequency selectivity of the binaural system than that of the monaural processing others seem to indicate the same frequency selectivity for monaural and binaural processing. This study provides an overview of these seemingly controversial results and the different explanations that were provided to account for the different results. © 2018 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.

  17. Outcome and cost analysis of bilateral sequential same-day cartilage tympanoplasty compared with bilateral staged tympanoplasty.

    PubMed

    Olusesi, A D; Oyeniran, O

    2017-05-01

    Few studies have compared bilateral same-day with staged tympanoplasty using cartilage graft materials. A prospective randomised observational study was performed of 38 chronic suppurative otitis media patients (76 ears) who were assigned to undergo bilateral sequential same-day tympanoplasty (18 patients, 36 ears) or bilateral sequential tympanoplasty performed 3 months apart (20 patients, 40 ears). Disease duration, intra-operative findings, combined duration of surgery, post-operative graft appearance at 6 weeks, post-operative complications, re-do rate and relative cost of surgery were recorded. Tympanic membrane perforations were predominantly subtotal (p = 0.36, odds ratio = 0.75). Most grafts were harvested from the conchal cartilage and fewer from the tragus (p = 0.59, odds ratio = 1.016). Types of complication, post-operative hearing gain and revision rates were similar in both patient groups. Surgical outcomes are not significantly different for same-day and bilateral cartilage tympanoplasty, but same-day surgery has the added benefit of a lower cost.

  18. Sampling the Deaf Experience.

    ERIC Educational Resources Information Center

    Teller, Henry E.; And Others

    1993-01-01

    Two graduate students in deaf education wore ear plugs for two months to simulate hearing loss, and recorded their experiences and feelings. Excerpts from their journals are presented, commenting on such daily activities as shopping at a mall, watching television, driving, babysitting, and attending a football game. (JDD)

  19. The influence of broadcast tape-recorded calls on captures of fall migrant Northern Saw-whet Owls (Aegolius acadicus) and Long-eared Owls (Asio otus)

    Treesearch

    David L. Evans

    1997-01-01

    Nocturnal netting operations have been conducted at the Hawk Ridge Nature Reserve since 1972. From 1988 to 1992 a recording of human whistles simulating the calls of fall migrant Northern Saw-whet Owls (Aegolius acadicus) was broadcast on a random, on or off, half-night basis. Mist net captures of Saw-whet Owls increased about fourfold during the...

  20. Statistical approach for the detection of motion/noise artifacts in Photoplethysmogram.

    PubMed

    Selvaraj, Nandakumar; Mendelson, Yitzhak; Shelley, Kirk H; Silverman, David G; Chon, Ki H

    2011-01-01

    Motion and noise artifacts (MNA) have been a serious obstacle in realizing the potential of Photoplethysmogram (PPG) signals for real-time monitoring of vital signs. We present a statistical approach based on the computation of kurtosis and Shannon Entropy (SE) for the accurate detection of MNA in PPG data. The MNA detection algorithm was verified on multi-site PPG data collected from both laboratory and clinical settings. The accuracy of the fusion of kurtosis and SE metrics for the artifact detection was 99.0%, 94.8% and 93.3% in simultaneously recorded ear, finger and forehead PPGs obtained in a clinical setting, respectively. For laboratory PPG data recorded from a finger with contrived artifacts, the accuracy was 88.8%. It was identified that the measurements from the forehead PPG sensor contained the most artifacts followed by finger and ear. The proposed MNA algorithm can be implemented in real-time as the computation time was 0.14 seconds using Matlab®.

  1. Perception of tilt and ocular torsion of vestibular patients during eccentric rotation.

    PubMed

    Clément, Gilles; Deguine, Olivier

    2010-01-04

    Four patients following unilateral vestibular loss and four patients complaining of otolith-dependent vertigo were tested during eccentric yaw rotation generating 1 x g centripetal acceleration directed along the interaural axis. Perception of body tilt in roll and in pitch was recorded in darkness using a somatosensory plate that the subjects maintained parallel to the perceived horizon. Ocular torsion was recorded by a video camera. Unilateral vestibular-defective patients underestimated the magnitude of the roll tilt and had a smaller torsion when the centrifugal force was towards the operated ear compared to the intact ear and healthy subjects. Patients with otolithic-dependent vertigo overestimated the magnitude of roll tilt in both directions of eccentric rotation relative to healthy subjects, and their ocular torsion was smaller than in healthy subjects. Eccentric rotation is a promising tool for the evaluation of vestibular dysfunction in patients. Eye torsion and perception of tilt during this stimulation are objective and subjective measurements, which could be used to determine alterations in spatial processing in the CNS.

  2. Ear epistheses as an alternative to autogenous reconstruction.

    PubMed

    Federspil, Philipp A

    2009-08-01

    An ear episthesis is an artificial substitute for the auricle. The term EAR PROSTHESIS is used synonymously. The breakthrough came with the introduction of the modern silicones and their colorings. Although there are still indications for noninvasive methods of retention such as medical adhesives, the best and most reliable method of fixation is by bone anchorage. Long-lasting osseointegration with reaction-free skin penetration can be achieved with titanium implants. The first system used extraorally was the Brånemark flange fixture. Later, different solitary titanium implants were introduced, such as the ITI system. A different strategy used the titanium grids (Epitec) or plates (Epiplating) derived from osteosynthesis systems. These systems are fixed subperiosteally with several bone screws and are therefore also labeled as grouped implants. With these modern developments, secure retention can be achieved also in unfavorable anatomic situations. The grouped systems are resistant to torque with abutment insertion. The latest development is the subcutaneously implanted double magnet without skin penetration. The advantages of implant retained ear epistheses include optimal camouflage, predictable cosmetic results, fast rehabilitation, no donor site morbidity, and early detection of tumor recurrence. Depending on the clinical setting, prosthetic rehabilitation may be more than just an alternative to plastic reconstructive surgery. Copyright Thieme Medical Publishers.

  3. Sensory hair cell regeneration in the zebrafish lateral line.

    PubMed

    Lush, Mark E; Piotrowski, Tatjana

    2014-10-01

    Damage or destruction of sensory hair cells in the inner ear leads to hearing or balance deficits that can be debilitating, especially in older adults. Unfortunately, the damage is permanent, as regeneration of the inner ear sensory epithelia does not occur in mammals. Zebrafish and other non-mammalian vertebrates have the remarkable ability to regenerate sensory hair cells and understanding the molecular and cellular basis for this regenerative ability will hopefully aid us in designing therapies to induce regeneration in mammals. Zebrafish not only possess hair cells in the ear but also in the sensory lateral line system. Hair cells in both organs are functionally analogous to hair cells in the inner ear of mammals. The lateral line is a mechanosensory system found in most aquatic vertebrates that detects water motion and aids in predator avoidance, prey capture, schooling, and mating. Although hair cell regeneration occurs in both the ear and lateral line, most research to date has focused on the lateral line due to its relatively simple structure and accessibility. Here we review the recent discoveries made during the characterization of hair cell regeneration in zebrafish. Copyright © 2014 Wiley Periodicals, Inc.

  4. Non-invasive, home-based electroencephalography hypoglycaemia warning system for personal monitoring using skin surface electrodes: a single-case feasibility study.

    PubMed

    Clewett, Christopher J; Langley, Phillip; Bateson, Anthony D; Asghar, Aziz; Wilkinson, Antony J

    2016-03-01

    Hypoglycaemia unawareness is a common condition associated with increased risk of severe hypoglycaemia. The purpose of the authors' study was to develop a simple to use, home-based and non-invasive hypoglycaemia warning system based on electroencephalography (EEG), and to demonstrate its use in a single-case feasibility study. A participant with type 1 diabetes forms a single-person case study where blood sugar levels and EEG were recorded. EEG was recorded using skin surface electrodes placed behind the ear located within the T3 region by the participant in the home. EEG was analysed retrospectively to develop an algorithm which would trigger a warning if EEG changes associated with hypoglycaemia onset were detected. All hypoglycaemia events were detected by the EEG hypoglycaemia warning algorithm. Warnings were triggered with blood glucose concentration levels at or below 4.2 mmol/l in this participant and no warnings were issued when in euglycaemia. The feasibility of a non-invasive EEG-based hypoglycaemia warning system for personal monitoring in the home has been demonstrated in a single case study. The results suggest that further studies are warranted to evaluate the system prospectively in a larger group of participants.

  5. The auditory neural network in man

    NASA Technical Reports Server (NTRS)

    Galambos, R.

    1975-01-01

    The principles of anatomy and physiology necessary for understanding brain wave recordings made from the scalp are briefly discussed. Brain waves evoked by sounds are then described and certain of their features are related to the physical aspects of the stimulus and the psychological state of the listener. It is proposed that data obtained through probes located outside the head can reveal a large amount of detail about brain activity. It is argued that analysis of such records enables one to detect the response of the nervous system to an acoustic message at the moment of its inception at the ear, and to follow the progress of the acoustic message up through the various brain levels as progressively more complex operations are performed upon it. Even those brain events responsible for the highest level of signal processing - distinguishing between similar signals and making decisions about them - seem to generate characteristic and identifiable electrical waves.

  6. Geomorphic Response to Spatial and Temporal Tectonic uplift on the Kenya Rift of East African Rift System

    NASA Astrophysics Data System (ADS)

    Xue, L.; Abdelsalam, M. G.

    2017-12-01

    Tectonic uplifts of the shoulders of the East Africa Rift System (EARS) have significant impact on the geological record by reorganizing drainage systems, increasing sediment supply, and changing climate and biogeography. Recent studies in geochronology, geomorphology and geophysics have provided some understanding of the timing of tectonic uplift and its distribution pattern of the (EARS). We do not know how the vertical motion is localized along the rift axis and the relative roles of upwelling of magma and rift extensional processes play in tectonic uplift history. This work presents detailed morphometric study of the fluvial landscape response to the tectonic uplift and climate shifting of the Kenya Rift shoulders in order to reconstruct their incision history, with special attention to timing, location, and intensity of uplift episodes. This work compiles the Shuttle Radar Topography Mission (SRTM) Digital Elevation Model (DEM) and Sentinel-2A data, summarized previous 39Ar-40Ar and thermochronology data, and calculates long-term incision rate and geomorphic proxies (normalized steepness and chi-integral) along the Kenya Rift. It also models the age of tectonic/climatic events by using knickpoint celerity model and R/SR integrative approach. It found that the maximum long-term incision rates of 300 mm/kyr to be at the central Kenya Rift, possibly related to the mantle-driven process and rapid tectonic uplift. The geomorphic proxies indicate southward decreasing pattern of the short-term incision rate, possibly related to the migration of the mantle plume.

  7. High-resolution x-ray computed tomography to understand ruminant phylogeny

    NASA Astrophysics Data System (ADS)

    Costeur, Loic; Schulz, Georg; Müller, Bert

    2014-09-01

    High-resolution X-ray computed tomography has become a vital technique to study fossils down to the true micrometer level. Paleontological research requires the non-destructive analysis of internal structures of fossil specimens. We show how X-ray computed tomography enables us to visualize the inner ear of extinct and extant ruminants without skull destruction. The inner ear, a sensory organ for hearing and balance has a rather complex three-dimensional morphology and thus provides relevant phylogenetical information what has been to date essentially shown in primates. We made visible the inner ears of a set of living and fossil ruminants using the phoenix x-ray nanotom®m (GE Sensing and Inspection Technologies GmbH). Because of the high absorbing objects a tungsten target was used and the experiments were performed with maximum accelerating voltage of 180 kV and a beam current of 30 μA. Possible stem ruminants of the living families are known in the fossil record but extreme morphological convergences in external structures such as teeth is a strong limitation to our understanding of the evolutionary history of this economically important group of animals. We thus investigate the inner ear to assess its phylogenetical potential for ruminants and our first results show strong family-level morphological differences.

  8. Head-Shaking Nystagmus Depends on Gravity

    PubMed Central

    Marti, Sarah; Straumann, Dominik

    2005-01-01

    In acute unilateral peripheral vestibular deficit, horizontal spontaneous nystagmus (SN) increases when patients lie on their affected ear. This phenomenon indicates an ipsilesional reduction of otolith function that normally suppresses asymmetric semicircular canal signals. We asked whether head-shaking nystagmus (HSN) in patients with chronic unilateral vestibular deficit following vestibular neuritis is influenced by gravity in the same way as SN in acute patients. Using a three-dimensional (3-D) turntable, patients (N = 7) were placed in different whole-body positions along the roll plane and oscillated (1 Hz, ±10°) about their head-fixed vertical axis. Eye movements were recorded with 3-D magnetic search coils. HSN was modulated by gravity: When patients lay on their affected ear, slow-phase eye velocity significantly increased upon head shaking and consisted of a horizontal drift toward the affected ear (average: 1.2°/s ±0.5 SD), which was added to the gravity-independent and directionally nonspecific SN. In conclusion, HSN in patients with chronic unilateral peripheral vestibular deficit is best elicited when they are lying on their affected ear. This suggests a gravity-dependent mechanism similar to the one observed for SN in acute patients, i.e., an asymmetric suppression of vestibular nystagmus by the unilaterally impaired otolith organs. PMID:15735939

  9. Local and Global Spatial Organization of Interaural Level Difference and Frequency Preferences in Auditory Cortex

    PubMed Central

    Panniello, Mariangela; King, Andrew J; Dahmen, Johannes C; Walker, Kerry M M

    2018-01-01

    Abstract Despite decades of microelectrode recordings, fundamental questions remain about how auditory cortex represents sound-source location. Here, we used in vivo 2-photon calcium imaging to measure the sensitivity of layer II/III neurons in mouse primary auditory cortex (A1) to interaural level differences (ILDs), the principal spatial cue in this species. Although most ILD-sensitive neurons preferred ILDs favoring the contralateral ear, neurons with either midline or ipsilateral preferences were also present. An opponent-channel decoder accurately classified ILDs using the difference in responses between populations of neurons that preferred contralateral-ear-greater and ipsilateral-ear-greater stimuli. We also examined the spatial organization of binaural tuning properties across the imaged neurons with unprecedented resolution. Neurons driven exclusively by contralateral ear stimuli or by binaural stimulation occasionally formed local clusters, but their binaural categories and ILD preferences were not spatially organized on a more global scale. In contrast, the sound frequency preferences of most neurons within local cortical regions fell within a restricted frequency range, and a tonotopic gradient was observed across the cortical surface of individual mice. These results indicate that the representation of ILDs in mouse A1 is comparable to that of most other mammalian species, and appears to lack systematic or consistent spatial order. PMID:29136122

  10. Wearable Sensing of In-Ear Pressure for Heart Rate Monitoring with a Piezoelectric Sensor

    PubMed Central

    Park, Jang-Ho; Jang, Dae-Geun; Park, Jung Wook; Youm, Se-Kyoung

    2015-01-01

    In this study, we developed a novel heart rate (HR) monitoring approach in which we measure the pressure variance of the surface of the ear canal. A scissor-shaped apparatus equipped with a piezoelectric film sensor and a hardware circuit module was designed for high wearability and to obtain stable measurement. In the proposed device, the film sensor converts in-ear pulse waves (EPW) into electrical current, and the circuit module enhances the EPW and suppresses noise. A real-time algorithm embedded in the circuit module performs morphological conversions to make the EPW more distinct and knowledge-based rules are used to detect EPW peaks. In a clinical experiment conducted using a reference electrocardiogram (ECG) device, EPW and ECG were concurrently recorded from 58 healthy subjects. The EPW intervals between successive peaks and their corresponding ECG intervals were then compared to each other. Promising results were obtained from the samples, specifically, a sensitivity of 97.25%, positive predictive value of 97.17%, and mean absolute difference of 0.62. Thus, highly accurate HR was obtained from in-ear pressure variance. Consequently, we believe that our proposed approach could be used to monitor vital signs and also utilized in diverse applications in the near future. PMID:26389912

  11. Radioprotective Effect of Aminothiol PrC-210 on Irradiated Inner Ear of Guinea Pig

    PubMed Central

    Choo, Daniel I.; Riazuddin, Saima; Ahmed, Zubair M.

    2015-01-01

    Radiotherapy of individuals suffering with head & neck or brain tumors subserve the risk of sensorineural hearing loss. Here, we evaluated the protective effect of Aminothiol PrC-210 (3-(methyl-amino)-2-((methylamino)methyl)propane-1-thiol) on the irradiated inner ear of guinea pigs. An intra-peritoneal or intra-tympanic dose of PrC-210 was administered prior to receiving a dose of gamma radiation (3000 cGy) to each ear. Auditory Brainstem Responses (ABRs) were recorded one week and two weeks after the radiation and compared with the sham animal group. ABR thresholds of guinea pigs that received an intra-peritoneal dose of PrC-210 were significantly better compared to the non-treated, control animals at one week post-radiation. Morphologic analysis of the inner ear revealed significant inflammation and degeneration of the spiral ganglion in the irradiated animals not treated with PrC-210. In contrast, when treated with PrC-210 the radiation effect and injury to the spiral ganglion was significantly alleviated. PrC-210 had no apparent cytotoxic effect in vivo and did not affect the morphology or count of cochlear hair cells. These findings suggest that aminothiol PrC-210 attenuated radiation-induced cochlea damage for at least one week and protected hearing. PMID:26599238

  12. [Basics of Ear Surgery].

    PubMed

    Lailach, S; Zahnert, T

    2016-12-01

    The present article about the basics of ear surgery is a short overview of current indications, the required diagnostics and surgical procedures of common otologic diseases. In addition to plastic and reconstructive surgery of the auricle, principles of surgery of the external auditory canal, basics of middle ear surgery and the tumor surgery of the temporal bone are shown. Additionally, aspects of the surgical hearing rehabilitation (excluding implantable hearing systems) are presented considering current study results. Georg Thieme Verlag KG Stuttgart · New York.

  13. Naturopathic treatment for ear pain in children.

    PubMed

    Sarrell, E Michael; Cohen, Herman Avner; Kahan, Ernesto

    2003-05-01

    Otitis media is 1 of the most frequent diseases of early infancy and childhood and 1 of the most common reasons for children to visit a physician. In the past 2 decades, there has been a substantial increase in the diagnosis of otitis media worldwide. In the United States, 93% of all children have had at least 1 episode of acute otitis media (AOM) by 7 years of age. Otalgia is the hallmark of AOM. Most affected children either complain of earache or manifest behavior that the parents interpret as indicating ear pain. Treatment of the ear pain early in the course of AOM decreases both parental anxiety and the child's discomfort and accelerates the healing process. The objective of this study was to determine the efficacy and tolerability of naturopathic versus traditional treatment for the management of otalgia commonly associated with AOM in children. The study was designed as a double-blind trial in an outpatient community clinic. A total of 171 children who were aged 5 to 18 years and had otalgia and clinical findings associated with middle-ear infection were studied. The children were randomly assigned to receive treatment with Naturopathic Herbal Extract Ear Drops (NHED) or anesthetic ear drops, with or without amoxicillin. On enrollment, the children were assigned by computer-numbered randomization to receive NHED (contents: allium sativum, verbascum thapsus, calendula flores, hypericum perfoliatum, lavender, and vitamin E in olive oil) 5 drops 3 times daily, alone (group A) or together with a topical anesthetic (amethocaine and phenazone in glycerin) 5 drops 3 times daily (group B), or oral amoxicillin 80 mg/kg/d (maximum 500 mg/dose) divided into 3 doses with either NHED 5 drops 3 times daily (group C) or topical anesthetic 5 drops 3 times daily (group D). A double-blind design was used, and all ear drops were placed in identical bottles. Treatment was initiated by the nurse in all cases. A single physician (M.S.) evaluated and treated all of the patients included in the study and recorded all of the data. The presence or absence of ear pain was assessed over 3 days with a visual analog scale. Ear pain was assessed by a specially devised observational instrument based on previous reports. One side of the instrument consisted of a linear numbered scale, from 1 (no pain) to 10 (worst possible pain), and a corresponding color scale, ranging from blue to dark red. The reverse side contained a scale of 5 facial expressions, ranging from broad smile (no pain) to a sad and crying face (worst possible pain), and a corresponding color scale, ranging from blue to dark red. There were no significant between-group differences in patient age or gender, degree of fever, main symptoms, associated symptoms, and severity or laterality of acute otitis media. Each group had a statistically significant improvement in ear pain over the course of the 3 days. Patients who were given ear drops alone had a better response than patients who were given ear drops together with amoxicillin. Results were better in the NHED group than in the controls. Nevertheless, the findings indicated that the pain was mostly (80%) self-limited and could be explained simply by the time elapsed. The American Academy of Otolaryngology-Head and Neck Surgery guidelines recommend topical medications as the first line of treatment for ear pain in the absence of systemic infection or serious underlying disease. Because no evidence was found that systemic antibiotics alone improved treatment outcome, if antibiotics do not change the natural course of otitis media, then the main goal of treatment, as in the present study, should be to alleviate the ear pain. The alternative, naturopathic herbal extract medications, may offer many new possibilities in the management of ear pain associated with AOM. Primary care physicians should be aware that at least 10% of their patients may have tried 1 or more forms of alternative/complementary medicine before presenting for consultation. As it was widely reported in the medical literature, these herb, these herbal extracts have the potential to meet all of the requirements of appropriate medication that could be routinely used in the pediatric patient, namely in vitro bacteriostatic and bacteriocidal activity against common pathogens, immunostimulation ability, antioxidant activity, and anti-inflammatory effects. They are also well-absorbed with good penetration into the tissue surrounding the tympanic membrane. They have been found to enhance local immunologic activity. Finally, herbal extracts are well-tolerated (owing to their long elimination time), easy to administer, and less expensive than the new antibiotics. There are no documented side effects. On the basis of our findings that the group with the most significant treatment effects (NHED with topical anesthetic) explained only 7.3% of the total pain reduction, we propose that sometimes the general practitioner or pediatrician needs to give the human body a chance to repair itself. Nevertheless, if the physician believes that there is an indication for some treatment, especially if the parents are anxious, then a local treatment such as one used in our study might be adequate. This study suggests that in cases of ear pain caused by AOM in children in which active treatment, besides a simple 2- to 3-day waiting period, is needed, an herbal extract solution may be beneficial. Concomitant antibiotic treatment is apparently not contributory.

  14. Comparative study of aural microflora in healthy cats, allergic cats and cats with systemic disease.

    PubMed

    Pressanti, Charline; Drouet, Clémence; Cadiergues, Marie-Christine

    2014-12-01

    Twenty healthy cats (group 1) with clinically normal ears, 15 cats with systemic disease (group 2) and 15 allergic cats (group 3) were included in a prospective study. The experimental unit was the ear. A clinical score was established for each ear canal after otoscopic examination. Microbial population was assessed on cytological examination of smears performed with the cotton-tipped applicator smear technique. Fungal population was significantly more prominent in allergic cats (P <0.001) and in diseased cats compared with healthy cats (P <0.02). Bacterial population was significantly higher in allergic cats than in healthy cats (P <0.001) and cats suffering from systemic disease (P <0.001). Bacterial overgrowth was also higher in cats with systemic disease than healthy cats. In cats from group 2, only fungal overgrowth was associated with otitis severity. In group 3, only bacterial overgrowth was associated with otitis severity. © ISFM and AAFP 2014.

  15. Self-demodulation of amplitude-modulated signal components in amplitude-modulated bone-conducted ultrasonic hearing

    NASA Astrophysics Data System (ADS)

    Ito, Kazuhito; Nakagawa, Seiji

    2015-07-01

    A novel hearing aid system utilizing amplitude-modulated bone-conducted ultrasound (AM-BCU) is being developed for use by profoundly deaf people. However, there is a lack of research on the acoustic aspects of AM-BCU hearing. In this study, acoustic fields in the ear canal under AM-BCU stimulation were examined with respect to the self-demodulation effect of amplitude-modulated signal components generated in the ear canal. We found self-demodulated signals with an audible sound pressure level related to the amplitude-modulated signal components of bone-conducted ultrasonic stimulation. In addition, the increases in the self-demodulated signal levels at low frequencies in the ear canal after occluding the ear canal opening, i.e., the positive occlusion effect, indicate the existence of a pathway by which the self-demodulated signals pass through the aural cartilage and soft tissue, and radiate into the ear canal.

  16. Eye movement analysis for activity recognition using electrooculography.

    PubMed

    Bulling, Andreas; Ward, Jamie A; Gellersen, Hans; Tröster, Gerhard

    2011-04-01

    In this work, we investigate eye movement analysis as a new sensing modality for activity recognition. Eye movement data were recorded using an electrooculography (EOG) system. We first describe and evaluate algorithms for detecting three eye movement characteristics from EOG signals-saccades, fixations, and blinks-and propose a method for assessing repetitive patterns of eye movements. We then devise 90 different features based on these characteristics and select a subset of them using minimum redundancy maximum relevance (mRMR) feature selection. We validate the method using an eight participant study in an office environment using an example set of five activity classes: copying a text, reading a printed paper, taking handwritten notes, watching a video, and browsing the Web. We also include periods with no specific activity (the NULL class). Using a support vector machine (SVM) classifier and person-independent (leave-one-person-out) training, we obtain an average precision of 76.1 percent and recall of 70.5 percent over all classes and participants. The work demonstrates the promise of eye-based activity recognition (EAR) and opens up discussion on the wider applicability of EAR to other activities that are difficult, or even impossible, to detect using common sensing modalities.

  17. Modification of otoacoustic emissions following ear-level exposure to MP3 player music.

    PubMed

    Bhagat, Shaum P; Davis, Anne M

    2008-12-01

    The purpose of this study was to examine if a pre-determined exposure level and duration of MP3 player music would result in significant changes in cochlear function when measured with audiometric and physiological methods. Distortion-product otoacoustic emissions (DPOAEs), synchronized spontaneous otoacoustic emissions (SSOAEs), and hearing thresholds were measured in 20 normal-hearing adults before and after a 30-minute MP3 player music exposure. DPOAEs were acquired with 65/45 dB SPL primary tones (f(2)=0.842-7.996 kHz) with a frequency resolution of 8 points/octave. A probe microphone system recorded ear-canal music levels and was used to equalize levels at approximately 85 dBC across individuals during the music presentation. Comparison of pre- and post-exposure measurements revealed no significant differences in hearing thresholds, but DPOAE levels in half-octave bands centered from 1.4-6.0 kHz were significantly reduced following the music exposure. Post-exposure shifts in SSOAE frequency and level were highly variable in individuals identified with SSOAEs. The results for the exposure conditions explored in this study indicate that changes in otoacoustic emissions may precede the development of music-induced hearing threshold shifts.

  18. Surgical and Technical Modalities for Hearing Restoration in Ear Malformations.

    PubMed

    Dazert, Stefan; Thomas, Jan Peter; Volkenstein, Stefan

    2015-12-01

    Malformations of the external and middle ear often go along with an aesthetic and functional handicap. Independent of additional aesthetic procedures, a successful functional hearing restoration leads to a tremendous gain in quality of life for affected patients. The introduction of implantable hearing systems (bone conduction and middle ear devices) offers new therapeutic options in this field. We focus on functional rehabilitation of patients with malformations, either by surgical reconstruction or the use of different implantable hearing devices, depending on the disease itself and the severity of malformation as well as hearing impairment. Patients with an open ear canal and minor malformations are good candidates for surgical hearing restoration of middle ear structures with passive titanium or autologous implants. In cases with complete fibrous or bony atresia of the ear canal, the most promising functional outcome and gain in quality of life can be expected with an active middle ear implant or a bone conduction device combined with a surgical aesthetic rehabilitation in a single or multi-step procedure. Although the surgical procedure for bone conduction devices is straightforward and safe, more sophisticated operations for active middle ear implants (e.g., Vibrant Soundbridge, MED-EL, Innsbruck, Austria) provide an improved speech discrimination in noise and the ability of sound localization compared with bone conduction devices where the stimulation reaches both cochleae. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  19. An in vitro model of murine middle ear epithelium.

    PubMed

    Mulay, Apoorva; Akram, Khondoker M; Williams, Debbie; Armes, Hannah; Russell, Catherine; Hood, Derek; Armstrong, Stuart; Stewart, James P; Brown, Steve D M; Bingle, Lynne; Bingle, Colin D

    2016-11-01

    Otitis media (OM), or middle ear inflammation, is the most common paediatric disease and leads to significant morbidity. Although understanding of underlying disease mechanisms is hampered by complex pathophysiology it is clear that epithelial abnormalities underpin the disease. There is currently a lack of a well-characterised in vitro model of the middle ear (ME) epithelium that replicates the complex cellular composition of the middle ear. Here, we report the development of a novel in vitro model of mouse middle ear epithelial cells (mMECs) at an air-liquid interface (ALI) that recapitulates the characteristics of the native murine ME epithelium. We demonstrate that mMECs undergo differentiation into the varied cell populations seen within the native middle ear. Proteomic analysis confirmed that the cultures secrete a multitude of innate defence proteins from their apical surface. We showed that the mMECs supported the growth of the otopathogen, nontypeable Haemophilus influenzae (NTHi), suggesting that the model can be successfully utilised to study host-pathogen interactions in the middle ear. Overall, our mMEC culture system can help to better understand the cell biology of the middle ear and improve our understanding of the pathophysiology of OM. The model also has the potential to serve as a platform for validation of treatments designed to reverse aspects of epithelial remodelling that underpin OM development. © 2016. Published by The Company of Biologists Ltd.

  20. Pulse Transit Time Measurement Using Seismocardiogram, Photoplethysmogram, and Acoustic Recordings: Evaluation and Comparison.

    PubMed

    Yang, Chenxi; Tavassolian, Negar

    2018-05-01

    This work proposes a novel method of pulse transit time (PTT) measurement. The proximal arterial location data are collected from seismocardiogram (SCG) recordings by placing a micro-electromechanical accelerometer on the chest wall. The distal arterial location data are recorded using an acoustic sensor placed inside the ear. The performance of distal location recordings is evaluated by comparing SCG-acoustic and SCG-photoplethysmogram (PPG) measurements. PPG and acoustic performances under motion noise are also compared. Experimental results suggest comparable performances for the acoustic-based and PPG-based devices. The feasibility of each PTT measurement method is validated for blood pressure evaluations and its limitations are analyzed.

  1. Auditory alert systems with enhanced detectability

    NASA Technical Reports Server (NTRS)

    Begault, Durand R. (Inventor)

    2008-01-01

    Methods and systems for distinguishing an auditory alert signal from a background of one or more non-alert signals. In a first embodiment, a prefix signal, associated with an existing alert signal, is provided that has a signal component in each of three or more selected frequency ranges, with each signal component in each of three or more selected level at least 3-10 dB above an estimated background (non-alert) level in that frequency range. The alert signal may be chirped within one or more frequency bands. In another embodiment, an alert signal moves, continuously or discontinuously, from one location to another over a short time interval, introducing a perceived spatial modulation or jitter. In another embodiment, a weighted sum of background signals adjacent to each ear is formed, and the weighted sum is delivered to each ear as a uniform background; a distinguishable alert signal is presented on top of this weighted sum signal at one ear, or distinguishable first and second alert signals are presented at two ears of a subject.

  2. Use of the 'real-ear to dial difference' to derive real-ear SPL from hearing level obtained with insert earphones.

    PubMed

    Munro, K J; Lazenby, A

    2001-10-01

    The electroacoustic characteristics of a hearing instrument are normally selected for individuals using data obtained during audiological assessment. The precise inter-relationship between the electroacoustic and audiometric variables is most readily appreciated when they have been measured at the same reference point, such as the tympanic membrane. However, it is not always possible to obtain the real-ear sound pressure level (SPL) directly if this is below the noise floor of the probe-tube microphone system or if the subject is unco-operative. The real-ear SPL may be derived by adding the subject's real-ear to dial difference (REDD) acoustic transform to the audiometer dial setting. The aim of the present study was to confirm the validity of the Audioscan RM500 to measure the REDD with the ER-3A insert earphone. A probe-tube microphone was used to measure the real-ear SPL and REDD from the right ears of 16 adult subjects ranging in age from 22 to 41 years (mean age 27 years). Measurements were made from 0.25 kHz to 6 kHz at a dial setting of 70 dB with an ER-3A insert earphone and two earmould configurations: the EAR-LINK foam ear-tip and the subjects' customized skeleton earmoulds. Mean REDD varied as a function of frequency but was typically approximately 12 dB with a standard deviation (SD) of +/- 1.7 dB and +/- 2.7 dB for the foam ear-tip and customized earmould, respectively. The mean test-retest difference of the REDD varied with frequency but was typically 0.5 dB (SD 1 dB). Over the frequency range 0.5-4 kHz, the derived values were found to be within 5 dB of the measured values in 95% of subjects when using the EAR-LINK foam ear-tip and within 4 dB when using the skeleton earmould. The individually measured REDD transform can be used in clinical practice to derive a valid estimate of real-ear SPL when it has not been possible to measure this directly.

  3. Fluid dynamics vascular theory of brain and inner-ear function in traumatic brain injury: a translational hypothesis for diagnosis and treatment.

    PubMed

    Shulman, Abraham; Strashun, Arnold M

    2009-01-01

    It is hypothesized that in all traumatic brain injury (TBI) patients with a clinical history of closed or penetrating head injury, the initial head trauma is associated with a vibratory sensation and noise exposure, with resultant alteration in vascular supply to the structures and contents of the fluid compartments of brain and ear (i.e., the fluid dynamics vascular theory of brain-inner-ear function [FDVTBE]). The primary etiology-head trauma-results in an initial fluctuation, interference, or interaction in the normal fluid dynamics between brain and labyrinth of the inner ear, with a resultant clinical diversity of complaints varying in time of onset and severity. Normal function of the brain and ear is a reflection of a normal state of homeostasis between the fluid compartments in the brain of cerebrospinal fluid and perilymph-endolymph in the labyrinth of the ear. The normal homeostasis in the structures and contents between the two fluid compartment systems--intracerebral and intralabyrinthine--is controlled by mechanisms involved in the maintenance of normal pressures, water and electrolyte content, and neurotransmitter activities. The initial pathophysiology (a reflection of an alteration in the vascular supply to the brain-ear) is hypothesized to be an initial acute inflammatory response, persistence of which results in ischemia and an irreversible alteration in the involved neural substrates of brain-ear. Clinically, a chronic multisymptom complex becomes manifest. The multisymptom complex, individual for each TBI patient regardless of the diagnostic TBI category (i.e., mild, moderate, or severe), initially reflects processes of inflammation and ischemia which, in brain, result in brain volume loss identified as neurodegeneration and hydrocephalus ex vacuo or an alteration in cerebrospinal fluid production (i.e., pseudotumor cerebri) and, in ear, secondary endolymphatic hydrops with associated cochleovestibular complaints of hearing loss, tinnitus, vertigo, ear blockage, and hyperacusis. The FDVTBE integrates and translates a neurovascular hypothesis for Alzheimer's disease to TBI. This study presents an FDVTBE hypothesis of TBI to explain the clinical association of head trauma (TBI) and central nervous system neurodegeneration with multisensory complaints, highlighted by and focusing on cochleovestibular complaints. A clinical case report, previously published for demonstration of the cerebrovascular medical significance of a particular type of tinnitus, and evidence-based basic science and clinical medicine are cited to provide objective evidence in support and demonstration of the FDVTBE.

  4. Effectiveness of binaural beats in reducing preoperative dental anxiety.

    PubMed

    Isik, B K; Esen, A; Büyükerkmen, B; Kilinç, A; Menziletoglu, D

    2017-07-01

    Binaural beats are an auditory illusion perceived when two different pure-tone sine waves are presented one to each ear at a steady intensity and frequency. We evaluated their effectiveness in reducing preoperative anxiety in dentistry. Sixty patients (30 in each group) who were to have impacted third molars removed were studied (experimental group: 20 women and 10 men, mean (range) age 24 (18-35) years, and control group: 22 women and 8 men, mean (range) age 28 (15-47) years). All patients were fully informed about the operation preoperatively, and their anxiety recorded on a visual analogue scale (VAS). The local anaesthetic was given and the patients waited for 10minutes, during which those in the experimental group were asked to listen to binaural beats through stereo earphones (200Hz for the left ear and 209.3Hz for the right ear). No special treatment was given to the control group. In both groups anxiety was then recorded again, and the tooth removed in the usual way. The paired t test and t test were used to assess the significance of differences between groups. The degree of anxiety in the control group was unchanged after the second measurement (p=0.625), while that in the experimental group showed a significant reduction in anxiety (p=0.001). We conclude that binaural beats may be useful in reducing preoperative anxiety in dentistry. Copyright © 2017 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  5. [How do metallic middle ear implants behave in the MRI?].

    PubMed

    Kwok, P; Waldeck, A; Strutz, J

    2003-01-01

    Magnetic resonance imaging (MRI) has gained in frequency and importance as a diagnostic procedure. In respect to the close anatomical relationship in the temporal bone it is necessary to know whether it is hazardous to patients with metallic middle ear implants regarding displacement and rise in temperature. For the MR image quality artefacts caused by metallic prostheses should be low. Four different stapes prostheses made from titanium, gold, teflon/platinum and teflon/steel, a titanium total ossicular reconstruction prosthesis (TORP) and two ventilation tubes (made from titanium and gold) were tested in a 1.5 Tesla MRI machine regarding their displacement. All objects were first placed in a petri dish, then suspended from a thread and finally immersed in a dish filled with Gadolinium. Temperature changes of the implants were recorded by a pyrometer. None of the implants moved when they were placed in the petri dish or suspended from the thread. On the water surface the teflon/platinum and the teflon/steel pistons adjusted their direction with their axis longitudinally to the MRI scanner opening and the teflon/steel piston floated towards the MRI-machine when put close enough to the scanner opening. No rise in temperature was recorded. All implants showed as little artefacts that would still make an evaluation of the surrounding tissue possible. Patients with any of the metallic middle ear implants that were examined in this study may undergo MRI-investigations without significant adverse effects.

  6. Tympanometric findings in superior semicircular canal dehiscence syndrome.

    PubMed

    Castellucci, A; Brandolini, C; Piras, G; Modugno, G C

    2013-04-01

    The diagnostic role of audio-impedancemetry in superior semicircular canal dehiscence (SSCD) disease is well known. In particular, since the first reports, the presence of evoked acoustic reflexes has represented a determining instrumental exhibit in differential diagnosis with other middle ear pathologies that are responsible for a mild-low frequencies air-bone gap (ABG). Even though high resolution computed tomography (HRCT) completed by parasagittal reformatted images still represents the diagnostic gold standard, several instrumental tests can support a suspect of labyrinthine capsule dehiscence when "suggestive" symptoms occur. Objective and subjective audiometry often represents the starting point of the diagnostic course aimed at investigating the cause responsible for the so-called "intra-labyrinthine conductive hearing loss". The purpose of this study is to evaluate the role of tympanometry, in particular of the inter-aural asymmetry ratio in peak compliance as a function of different mild-low frequencies ABG on the affected side, in the diagnostic work-up in patients with unilateral SSCD. The working hypothesis is that an increase in admittance of the "inner-middle ear" conduction system due to a "third mobile window" could be detected by tympanometry. A retrospective review of the clinical records of 45 patients with unilateral dehiscence selected from a pool of 140 subjects diagnosed with SSCD at our institution from 2003 to 2011 was performed. Values of ABG amplitude on the dehiscent side and tympanometric measurements of both ears were collected for each patient in the study group (n = 45). An asymmetry between tympanometric peak compliance of the involved side and that of the contralateral side was investigated by calculating the inter-aural difference and the asymmetry ratio of compliance at the eardrum. A statistically significant correlation (p = 0.015 by Fisher's test) between an asymmetry ratio ≥ 14% in favour of the pathologic ear and an ABG > 20 dB nHL on the same side was found. When "evocative" symptoms of SSCD associated with important ABG occur, the inter-aural difference in tympanometric peak compliance at the eardrum in favour of the "suspected" side could suggest an intra-labyrinthine origin for the asymmetry. Tympanometry would thus prove to be a useful instrument in clinical-instrumental diagnosis of SSCD in detection of cases associated with alterations of inner ear impedance.

  7. Cognitive Factors in Sexual Arousal: The Role of Distraction

    ERIC Educational Resources Information Center

    Geer, James H.; Fuhr, Robert

    1976-01-01

    Four groups of male undergraduates were instructed to perform complex cognitive operations when randomly presented single digits of a dichotic listening paradigm. An erotic tape recording was played into the nonattended ear. Sexual arousal varied directly as a function of the complexity of the distracting cognitive operations. (Author)

  8. Stimulus change detection in phasic auditory units in the frog midbrain: frequency and ear specific adaptation.

    PubMed

    Ponnath, Abhilash; Hoke, Kim L; Farris, Hamilton E

    2013-04-01

    Neural adaptation, a reduction in the response to a maintained stimulus, is an important mechanism for detecting stimulus change. Contributing to change detection is the fact that adaptation is often stimulus specific: adaptation to a particular stimulus reduces excitability to a specific subset of stimuli, while the ability to respond to other stimuli is unaffected. Phasic cells (e.g., cells responding to stimulus onset) are good candidates for detecting the most rapid changes in natural auditory scenes, as they exhibit fast and complete adaptation to an initial stimulus presentation. We made recordings of single phasic auditory units in the frog midbrain to determine if adaptation was specific to stimulus frequency and ear of input. In response to an instantaneous frequency step in a tone, 28% of phasic cells exhibited frequency specific adaptation based on a relative frequency change (delta-f=±16%). Frequency specific adaptation was not limited to frequency steps, however, as adaptation was also overcome during continuous frequency modulated stimuli and in response to spectral transients interrupting tones. The results suggest that adaptation is separated for peripheral (e.g., frequency) channels. This was tested directly using dichotic stimuli. In 45% of binaural phasic units, adaptation was ear specific: adaptation to stimulation of one ear did not affect responses to stimulation of the other ear. Thus, adaptation exhibited specificity for stimulus frequency and lateralization at the level of the midbrain. This mechanism could be employed to detect rapid stimulus change within and between sound sources in complex acoustic environments.

  9. Suboptimal Vitamin B Intakes of Zambian Preschool Children: Evaluation of 24-Hour Dietary Recalls.

    PubMed

    Titcomb, Tyler J; Schmaelzle, Samantha T; Nuss, Emily T; Gregory, Jesse F; Tanumihardjo, Sherry A

    2018-06-01

    Hidden hunger affects individuals who chronically consume an inadequate intake of at least 1 micronutrient and is associated with low dietary diversity. Little data are available on dietary intake or status assessment of B vitamins among preschool children in Zambia. The aim of this study was to assess 24-hour dietary recall records obtained from Zambian children aged 3 to 7 years for B vitamin intake in relation to adequacy and change over time in the same community. Twenty-four-hour dietary recalls were collected from 2 studies that were 2 years apart in the same district of Zambia. Data were retrospectively analyzed for B vitamin intake, that is, biotin, vitamin B 12 , folate, niacin, pantothenic acid, vitamin B 6 , riboflavin, and thiamin. The estimated average requirement (EAR) cut point method was used to assess inadequacy prevalence for EARs established by the Institute of Medicine in the United States. For all B vitamins, mean values were below the EARs established for children 4 to 8 years old. Relative to the EAR, children had the highest intakes of vitamin B 6 with inadequacies of 77.9% and 60.1% in 2010 and 2012, respectively. The highest prevalence of inadequate intake was associated with folate, where ≥95% of the children had intakes below the EAR in both studies. All median vitamin B intakes were inadequate among these young children in rural Zambia. Future researchers and policy makers may need to consider B vitamin status in resource-poor areas of the country.

  10. Ascorbic acid reduces noise-induced nitric oxide production in the guinea pig ear.

    PubMed

    Heinrich, Ulf-Rüdiger; Fischer, Ilka; Brieger, Jürgen; Rümelin, Andreas; Schmidtmann, Irene; Li, Huige; Mann, Wolf J; Helling, Kai

    2008-05-01

    Noise-induced hearing loss can be caused, among other causes, by increased nitric oxide (NO) production in the inner ear leading to nitroactive stress and cell destruction. Some studies in the literature suggest that the degree of hearing loss (HL) could be reduced in an animal model through ascorbic acid supplementation. To identify the effect of ascorbic acid on tissue-dependent NO content in the inner ear of the guinea pig, we determined the local NO production in the organ of Corti and the lateral wall separately 6 hours after noise exposure. Prospective animal study in guinea pigs. Over a period of 7 days, male guinea pigs were supplied with minimum (25 mg/kg body weight/day) and maximum (525 mg/kg body weight/day) ascorbic acid doses, and afterwards exposed to noise (90 dB sound pressure level for 1 hour). The acoustic-evoked potentials were recorded before and after noise exposure. The organ of Corti and the lateral wall were incubated differently for 6 hours in culture medium, and the degree of NO production was determined by chemiluminescence. Ascorbic acid treatment reduced the hearing threshold shift after noise exposure depending on concentration. When the maximum ascorbic acid dose was substituted, NO production was significantly reduced in the lateral wall after noise exposure and slightly reduced in the organ of Corti. Oral supplementation of the natural radical scavenger ascorbic acid reduces the NO-production rate in the inner ear in noisy conditions. This finding supports the concept of inner ear protection by ascorbic acid supplementation.

  11. Stimulus change detection in phasic auditory units in the frog midbrain: frequency and ear specific adaptation

    PubMed Central

    Ponnath, Abhilash; Hoke, Kim L.

    2013-01-01

    Neural adaptation, a reduction in the response to a maintained stimulus, is an important mechanism for detecting stimulus change. Contributing to change detection is the fact that adaptation is often stimulus specific: adaptation to a particular stimulus reduces excitability to a specific subset of stimuli, while the ability to respond to other stimuli is unaffected. Phasic cells (e.g., cells responding to stimulus onset) are good candidates for detecting the most rapid changes in natural auditory scenes, as they exhibit fast and complete adaptation to an initial stimulus presentation. We made recordings of single phasic auditory units in the frog midbrain to determine if adaptation was specific to stimulus frequency and ear of input. In response to an instantaneous frequency step in a tone, 28 % of phasic cells exhibited frequency specific adaptation based on a relative frequency change (delta-f = ±16 %). Frequency specific adaptation was not limited to frequency steps, however, as adaptation was also overcome during continuous frequency modulated stimuli and in response to spectral transients interrupting tones. The results suggest that adaptation is separated for peripheral (e.g., frequency) channels. This was tested directly using dichotic stimuli. In 45 % of binaural phasic units, adaptation was ear specific: adaptation to stimulation of one ear did not affect responses to stimulation of the other ear. Thus, adaptation exhibited specificity for stimulus frequency and lateralization at the level of the midbrain. This mechanism could be employed to detect rapid stimulus change within and between sound sources in complex acoustic environments. PMID:23344947

  12. Implementing electronic identification for performance recording in sheep: II. Cost-benefit analysis in meat and dairy farms.

    PubMed

    Ait-Saidi, A; Caja, G; Salama, A A K; Milán, M J

    2014-12-01

    Costs and secondary benefits of implementing electronic identification (e-ID) for performance recording (i.e., lambing, body weight, inventory, and milk yield) in dairy and meat ewes were assessed by using the results from a previous study in which manual (M), semiautomatic (SA), and automatic (AU) data collection systems were compared. Ewes were identified with visual ear tags and electronic rumen boluses. The M system used visual identification, on-paper data recording, and manual data uploading to a computer. The SA system used e-ID with a handheld reader in which performances were typed and automatic uploaded to a computer. The use of a personal digital assistant (PDA) for recording and automatic data uploading, which transformed M in a SA system, was also considered. The AU system was only used for BW recording and consisted of e-ID, automatic data recording in an electronic scale, and uploading to a computer. The cost-benefit study was applied to 2 reference sheep farms of 700 meat ewes, under extensive or intensive production systems, and of 400 dairy ewes, practicing once- or twice-a-day machine milkings. Sensitivity analyses under voluntary and mandatory e-ID scenarios were also included. Benefits of using e-ID for SA or AU performance recording mainly depended on sheep farm purpose, number of test days per year, handheld reader and PDA prices, and flock size. Implementing e-ID for SA and AU performance recording saved approximately 50% of the time required by the M system, and increased the reliability of the data collected. Use of e-ID increased the cost of performance recording in a voluntary e-ID scenario, paying only partially the investment made (15 to 70%). For the mandatory e-ID scenario, in which the cost of e-ID devices was not included, savings paid 100% of the extra costs needed for using e-ID in all farm types and conditions. In both scenarios, the reader price was the most important extra cost (40 to 90%) for implementing e-ID in sheep farms. Calculated extra costs of using the PDA covered more than 100% of the implementation costs in all type of sheep farms, indicating that this device was cost-effective for sheep-performance recording. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  13. A Hydrodynamic Model of Transport in the Wheat Ear

    NASA Technical Reports Server (NTRS)

    Stieber, Joseph; Stieber, Joli; Bubenheim, David L.; Kliss, Mark (Technical Monitor)

    1996-01-01

    The vascular arrangement in the main axis (rachis) of the wheat ear, studied and reported in a previous paper by the same, described a circuit-cascade system consisting of capacitance and resistance passages (so-called RC-circuits). Some hydromechanic aspects (e.g., resonance, impulse control) of this asymmetric transport system and their possible role and importance in the fluid supply are discussed. A theoretical analysis of how this system works, as well as samples of practical application are presented.

  14. Source analysis of short and long latency vestibular-evoked potentials (VsEPs) produced by left vs. right ear air-conducted 500 Hz tone pips.

    PubMed

    Todd, N P M; Paillard, A C; Kluk, K; Whittle, E; Colebatch, J G

    2014-06-01

    Todd et al. (2014) have recently demonstrated the presence of vestibular dependent changes both in the morphology and in the intensity dependence of auditory evoked potentials (AEPs) when passing through the vestibular threshold as determined by vestibular evoked myogenic potentials (VEMPs). In this paper we extend this work by comparing left vs. right ear stimulation and by conducting a source analysis of the resulting evoked potentials of short and long latency. Ten healthy, right-handed subjects were recruited and evoked potentials were recorded to both left- and right-ear sound stimulation, above and below vestibular threshold. Below VEMP threshold, typical AEPs were recorded, consisting of mid-latency (MLR) waves Na and Pa followed by long latency AEPs (LAEPs) N1 and P2. In the supra-threshold condition, the expected changes in morphology were observed, consisting of: (1) short-latency vestibular evoked potentials (VsEPs) which have no auditory correlate, i.e. the ocular VEMP (OVEMP) and inion response related potentials; (2) a later deflection, labelled N42/P52, followed by the LAEPs N1 and P2. Statistical analysis of the vestibular dependent responses indicated a contralateral effect for inion related short-latency responses and a left-ear/right-hemisphere advantage for the long-latency responses. Source analysis indicated that the short-latency effects may be mediated by a contralateral projection to left cerebellum, while the long-latency effects were mediated by a contralateral projection to right cingulate cortex. In addition we found evidence of a possible vestibular contribution to the auditory T-complex in radial temporal lobe sources. These last results raise the possibility that acoustic activation of the otolith organs could potentially contribute to auditory processing. Copyright © 2014 The Authors. Published by Elsevier B.V. All rights reserved.

  15. Development of a finite element model of the middle ear.

    PubMed

    Williams, K R; Blayney, A W; Rice, H J

    1996-01-01

    A representative finite element model of the healthy ear is developed commencing with a description of the decoupled isotropic tympanic membrane. This model was shown to vibrate in a manner similar to that found both numerically (1, 2) and experimentally (8). The introduction of a fibre system into the membrane matrix significantly altered the modes of vibration. The first mode "remains as a piston like movement as for the isotropic membrane. However, higher modes show a simpler vibration pattern similar to the second mode but with a varying axis of movement and lower amplitudes. The introduction of a malleus and incus does not change the natural frequencies or mode shapes of the membrane for certain support conditions. When constraints are imposed along the ossicular chain by simulation of a cochlear impedance term then significantly altered modes can occur. More recently a revised model of the ear has been developed by the inclusion of the outer ear canal. This discretisation uses geometries extracted from a Nuclear Magnetic resonance scan of a healthy subject and a crude inner ear model using stiffness parameters ultimately fixed through a parameter tuning process. The subsequently tuned model showed behaviour consistent with previous findings and should provide a good basis for subsequent modelling of diseased ears and assessment of the performance of middle ear prostheses.

  16. Non-invasive biophysical measurement of travelling waves in the insect inner ear

    PubMed Central

    2017-01-01

    Frequency analysis in the mammalian cochlea depends on the propagation of frequency information in the form of a travelling wave (TW) across tonotopically arranged auditory sensilla. TWs have been directly observed in the basilar papilla of birds and the ears of bush-crickets (Insecta: Orthoptera) and have also been indirectly inferred in the hearing organs of some reptiles and frogs. Existing experimental approaches to measure TW function in tetrapods and bush-crickets are inherently invasive, compromising the fine-scale mechanics of each system. Located in the forelegs, the bush-cricket ear exhibits outer, middle and inner components; the inner ear containing tonotopically arranged auditory sensilla within a fluid-filled cavity, and externally protected by the leg cuticle. Here, we report bush-crickets with transparent ear cuticles as potential model species for direct, non-invasive measuring of TWs and tonotopy. Using laser Doppler vibrometry and spectroscopy, we show that increased transmittance of light through the ear cuticle allows for effective non-invasive measurements of TWs and frequency mapping. More transparent cuticles allow several properties of TWs to be precisely recovered and measured in vivo from intact specimens. Our approach provides an innovative, non-invasive alternative to measure the natural motion of the sensilla-bearing surface embedded in the intact inner ear fluid. PMID:28573026

  17. Middle-ear velocity transfer function, cochlear input immittance, and middle-ear efficiency in chinchilla.

    PubMed

    Ravicz, Michael E; Rosowski, John J

    2013-10-01

    The transfer function H(V) between stapes velocity V(S) and sound pressure near the tympanic membrane P(TM) is a descriptor of sound transmission through the middle ear (ME). The ME power transmission efficiency (MEE), the ratio of sound power entering the cochlea to power entering the middle ear, was computed from H(V) measured in seven chinchilla ears and previously reported measurements of ME input admittance Y(TM) and ME pressure gain G(MEP) [Ravicz and Rosowski, J. Acoust. Soc. Am. 132, 2437-2454 (2012); J. Acoust. Soc. Am. 133, 2208-2223 (2013)] in the same ears. The ME was open, and a pressure sensor was inserted into the cochlear vestibule for most measurements. The cochlear input admittance Y(C) computed from H(V) and G(MEP) is controlled by a combination of mass and resistance and is consistent with a minimum-phase system up to 27 kHz. The real part Re{Y(C)}, which relates cochlear sound power to inner-ear sound pressure, decreased gradually with frequency up to 25 kHz and more rapidly above that. MEE was about 0.5 between 0.1 and 8 kHz, higher than previous estimates in this species, and decreased sharply at higher frequencies.

  18. Middle-ear velocity transfer function, cochlear input immittance, and middle-ear efficiency in chinchilla

    PubMed Central

    Ravicz, Michael E.; Rosowski, John J.

    2013-01-01

    The transfer function HV between stapes velocity VS and sound pressure near the tympanic membrane PTM is a descriptor of sound transmission through the middle ear (ME). The ME power transmission efficiency (MEE), the ratio of sound power entering the cochlea to power entering the middle ear, was computed from HV measured in seven chinchilla ears and previously reported measurements of ME input admittance YTM and ME pressure gain GMEP [Ravicz and Rosowski, J. Acoust. Soc. Am. 132, 2437–2454 (2012); J. Acoust. Soc. Am. 133, 2208–2223 (2013)] in the same ears. The ME was open, and a pressure sensor was inserted into the cochlear vestibule for most measurements. The cochlear input admittance YC computed from HV and GMEP is controlled by a combination of mass and resistance and is consistent with a minimum-phase system up to 27 kHz. The real part Re{YC}, which relates cochlear sound power to inner-ear sound pressure, decreased gradually with frequency up to 25 kHz and more rapidly above that. MEE was about 0.5 between 0.1 and 8 kHz, higher than previous estimates in this species, and decreased sharply at higher frequencies. PMID:24116422

  19. Gross and fine dissection of inner ear sensory epithelia in adult zebrafish (Danio rerio).

    PubMed

    Liang, Jin; Burgess, Shawn M

    2009-05-08

    Neurosensory epithelia in the inner ear are the crucial structures for hearing and balance functions. Therefore, it is important to understand the cellular and molecular features of the epithelia, which are mainly composed of two types of cells: hair cells (HCs) and supporting cells (SCs). Here we choose to study the inner ear sensory epithelia in adult zebrafish not only because the epithelial structures are highly conserved in all vertebrates studied, but also because the adult zebrafish is able to regenerate HCs, an ability that mammals lose shortly after birth. We use the inner ear of adult zebrafish as a model system to study the mechanisms of inner ear HC regeneration in adult vertebrates that could be helpful for clinical therapy of hearing/balance deficits in human as a result of HC loss. Here we demonstrate how to do gross and fine dissections of inner ear sensory epithelia in adult zebrafish. The gross dissection removes the tissues surrounding the inner ear and is helpful for preparing tissue sections, which allows us to examine the detailed structure of the sensory epithelia. The fine dissection cleans up the non-sensory-epithelial tissues of each individual epithelium and enables us to examine the heterogeneity of the whole epithelium easily in whole-mount epithelial samples.

  20. Evolution of vertebrate mechanosensory hair cells and inner ears: toward identifying stimuli that select mutation driven altered morphologies

    PubMed Central

    Fritzsch, Bernd; Straka, Hans

    2014-01-01

    Among the major distance senses of vertebrates, the ear is unique in its complex morphological changes during evolution. Conceivably, these changes enable the ear to adapt toward sensing various physically well-characterized stimuli. This review develops a scenario that integrates sensory cell with organ evolution. We propose that molecular and cellular evolution of the vertebrate hair cells occurred prior to the formation of the vertebrate ear. We previously proposed that the genes driving hair cell differentiation, were aggregated in the otic region through developmental re-patterning that generated a unique vertebrate embryonic structure, the otic placode. In agreement with the presence of graviceptive receptors in many vertebrate outgroups, it is likely that the vertebrate ear originally functioned as a simple gravity-sensing organ. Based on the rare occurrence of angular acceleration receptors in vertebrate outgroups, we further propose that the canal system evolved with a more sophisticated ear morphogenesis. This evolving morphogenesis obviously turned the initial otocyst into a complex set of canals and recesses, harboring multiple sensory epithelia each adapted to the acquisition of a specific aspect of a given physical stimulus. As support for this evolutionary progression, we provide several details of the molecular basis of ear development. PMID:24281353

  1. A Mosaicking Approach for In Vivo Thickness Mapping of the Human Tympanic Membrane Using Low Coherence Interferometry.

    PubMed

    Pande, Paritosh; Shelton, Ryan L; Monroy, Guillermo L; Nolan, Ryan M; Boppart, Stephen A

    2016-10-01

    The thickness of the human tympanic membrane (TM) is known to vary considerably across different regions of the TM. Quantitative determination of the thickness distribution and mapping of the TM is of significant importance in hearing research, particularly in mathematical modeling of middle-ear dynamics. Change in TM thickness is also associated with several middle-ear pathologies. Determination of the TM thickness distribution could therefore also enable a more comprehensive diagnosis of various otologic diseases. Despite its importance, very limited data on human TM thickness distribution, obtained almost exclusively from ex vivo samples, are available in the literature. In this study, the thickness distribution for the in vivo human TM is reported for the first time. A hand-held imaging system, which combines a low coherence interferometry (LCI) technique for single-point thickness measurement, with video-otoscopy for recording the image of the TM, was used to collect the data used in this study. Data were acquired by pointing the imaging probe over different regions of the TM, while simultaneously recording the LCI and concomitant TM surface video image data from an average of 500 locations on the TM. TM thickness distribution maps were obtained by mapping the LCI imaging sites onto an anatomically accurate wide-field image of the TM, which was generated by mosaicking the sequence of multiple small field-of-view video-otoscopy images. Descriptive statistics of the thickness measurements obtained from the different regions of the TM are presented, and the general thickness distribution trends are discussed.

  2. Hyperspectral imaging system for whole corn ear surface inspection

    NASA Astrophysics Data System (ADS)

    Yao, Haibo; Kincaid, Russell; Hruska, Zuzana; Brown, Robert L.; Bhatnagar, Deepak; Cleveland, Thomas E.

    2013-05-01

    Aflatoxin is a mycotoxin produced mainly by Aspergillus flavus (A.flavus) and Aspergillus parasitiucus fungi that grow naturally in corn. Very serious health problems such as liver damage and lung cancer can result from exposure to high toxin levels in grain. Consequently, many countries have established strict guidelines for permissible levels in consumables. Conventional chemical-based analytical methods used to screen for aflatoxin such as thin-layer chromatography (TLC) and high performance liquid chromatography (HPLC) are time consuming, expensive, and require the destruction of samples as well as proper training for data interpretation. Thus, it has been a continuing effort within the research community to find a way to rapidly and non-destructively detect and possibly quantify aflatoxin contamination in corn. One of the more recent developments in this area is the use of spectral technology. Specifically, fluorescence hyperspectral imaging offers a potential rapid, and non-invasive method for contamination detection in corn infected with toxigenic A.flavus spores. The current hyperspectral image system is designed for scanning flat surfaces, which is suitable for imaging single or a group of corn kernels. In the case of a whole corn cob, it is preferred to be able to scan the circumference of the corn ear, appropriate for whole ear inspection. This paper discusses the development of a hyperspectral imaging system for whole corn ear imaging. The new instrument is based on a hyperspectral line scanner using a rotational stage to turn the corn ear.

  3. THE POTENTIAL ROLE OF ENDOGENOUS STEM CELLS IN REGENERATION OF THE INNER EAR

    PubMed Central

    Martinez-Monedero, Rodrigo; Oshima, Kazuo; Heller, Stefan; Edge, Albert S.B.

    2007-01-01

    Stem cells in various mammalian tissues retain the capacity to renew themselves and may be able to restore damaged tissue. Their existence has been proven by genetic tracer studies that demonstrate their differentiation into multiple tissue types and by their ability to self-renew through proliferation. Stem cells from the adult nervous system proliferate to form clonal floating colonies called spheres in vitro, and recent studies have demonstrated sphere formation by cells in the cochlea in addition to the vestibular system and the auditory ganglia, indicating that these tissues contain cells with stem cell properties. The presence of stem cells in the inner ear raises the hope of regeneration of mammalian inner ear cells but is difficult to correlate with the lack spontaneous regeneration seen in the inner ear after tissue damage. Loss of stem cells postnatally in the cochlea may correlate with the loss of regenerative capacity and may limit our ability to stimulate regeneration. Retention of sphere forming capacity in adult vestibular tissues suggests that the limited capacity for repair may be attributed to the continued presence of progenitor cells. Future strategies for regeneration must consider the distribution of endogenous stem cells in the inner ear and whether cells with the capacity for regeneration are retained. PMID:17321086

  4. Circadian rhythms of visual accommodation responses and physiological correlations.

    NASA Technical Reports Server (NTRS)

    Murphy, M. R.; Randle, R. J.; Williams, B. A.

    1972-01-01

    Use of a recently developed servocontrolled infrared optometer to continuously record the state of monocular focus while subjects viewed a visual target for which the stimulus to focus was systematically varied. Calculated parameters form recorded data - e.g., speeds of accommodation to approaching and receding targets, magnitude of accommodation to step changes in target distance, and amplitude and phase lag of response to sinusoidally varying stimuli were submitted to periodicity analyses. Ear canal temperature (ECT) and heart rate (HR) rhythms were also recorded for physiological correlation with accommodation rhythms. HR demonstrated a 24-hr rhythm, but ECT data did not.

  5. Effects of High Sound Exposure During Air-Conducted Vestibular Evoked Myogenic Potential Testing in Children and Young Adults.

    PubMed

    Rodriguez, Amanda I; Thomas, Megan L A; Fitzpatrick, Denis; Janky, Kristen L

    Vestibular evoked myogenic potential (VEMP) testing is increasingly utilized in pediatric vestibular evaluations due to its diagnostic capability to identify otolith dysfunction and feasibility of testing. However, there is evidence demonstrating that the high-intensity stimulation level required to elicit a reliable VEMP response causes acoustic trauma in adults. Despite utility of VEMP testing in children, similar findings are unknown. It is hypothesized that increased sound exposure may exist in children because differences in ear-canal volume (ECV) compared with adults, and the effect of stimulus parameters (e.g., signal duration and intensity) will alter exposure levels delivered to a child's ear. The objectives of this study are to (1) measure peak to peak equivalent sound pressure levels (peSPL) in children with normal hearing (CNH) and young adults with normal hearing (ANH) using high-intensity VEMP stimuli, (2) determine the effect of ECV on peSPL and calculate a safe exposure level for VEMP, and (3) assess whether cochlear changes exist after VEMP exposure. This was a 2-phase approach. Fifteen CNH and 12 ANH participated in phase I. Equivalent ECV was measured. In 1 ear, peSPL was recorded for 5 seconds at 105 to 125 dB SPL, in 5-dB increments for 500- and 750-Hz tone bursts. Recorded peSPL values (accounting for stimulus duration) were then used to calculate safe sound energy exposure values for VEMP testing using the 132-dB recommended energy allowance from the 2003 European Union Guidelines. Fifteen CNH and 10 ANH received cervical and ocular VEMP testing in 1 ear in phase II. Subjects completed tympanometry, pre- and postaudiometric threshold testing, distortion product otoacoustic emissions, and questionnaire addressing subjective otologic symptoms to study the effect of VEMP exposure on cochlear function. (1) In response to high-intensity stimulation levels (e.g., 125 dB SPL), CNH had significantly higher peSPL measurements and smaller ECVs compared with ANH. (2) A significant linear relationship between equivalent ECV (as measured by diagnostic tympanometry) and peSPL exists and has an effect on total sound energy exposure level; based on data from phase I, 120 dB SPL was determined to be an acoustically safe stimulation level for testing in children. (3) Using calculated safe stimulation level for VEMP testing, there were no significant effect of VEMP exposure on cochlear function (as measured by audiometric thresholds, distortion product otoacoustic emission amplitude levels, or subjective symptoms) in CNH and ANH. peSPL sound recordings in children's ears are significantly higher (~3 dB) than that in adults in response to high-intensity VEMP stimuli that are commonly practiced. Equivalent ECV contributes to peSPL delivered to the ear during VEMP testing and should be considered to determine safe acoustic VEMP stimulus parameters; children with smaller ECVs are at risk for unsafe sound exposure during routine VEMP testing, and stimuli should not exceed 120 dB SPL. Using 120 dB SPL stimulus level for children during VEMP testing yields no change to cochlear function and reliable VEMP responses.

  6. Effects of injection position and transponder size on the performances of passive injectable transponders used for the electronic identification of cattle.

    PubMed

    Conill, C; Caja, G; Nehring, R; Ribó, O

    2000-12-01

    A total of 686 Tiris half-duplex passive injectable transponders (PIT) of two sizes (23 and 32 mm) were randomly injected s.c. in three positions, armpit, ear scutulum, and upper lip, in 343 fattening calves (1 to 3 mo old). Injections were performed by two trained and two untrained operators. Losses and breakages on the farm were recorded at wk 1, 3, 7, 11, and 15 in restrained animals using two types of hand-held transceivers with a stick antenna. Dynamic reading efficiency (DRE) in animals running through a raceway was also evaluated at wk 1 and 3 and monthly until slaughter, using a stationary transceiver working at 137 dB x microV x m(-1) at 3 m. The total number of PIT that fell or broke in the slaughtering line, the location method, and the recovery time were also recorded. Results on the farm showed low breakages on average (0.4%) and differences (P < 0.05) in losses according to position (armpit, 1.7%; ear, 5.2%; and lip, 14.0%). An interaction (P < 0.05) between position x size was observed, and losses were greatest using a 32-mm PIT in the lip. The DRE was affected (P < 0.05) by PIT position and size, and values were greater for the 32-mm PIT in all positions (armpit: 99.9 +/- 0.1 vs 95.8 +/- 4.9%; ear: 93.8 +/- 2.2 vs 81.9 +/- 4.6%; lip: 66.8 +/- 4.9 vs 53.4 +/- 4.7%, respectively, for 32 vs 23 mm). Recovery of PIT in the abattoir was on average 96.7, 96.7, and 99.2% for armpit, ear, and lip, respectively (P > 0.05). Most of the PIT injected in the armpit were recovered by sight or palpation, but 31.9% were recovered after cutting the muscles around the area and 10.7% were recovered on the internal side of the hide, which jeopardized carcass identification. Recovery of PIT injected in the ear was 23.4% in the hide and 76.6% in the auricular muscles of the head. The easiest recovery was in the lip, 8.9% of PIT were located in the hide and 91.1% in the head. Recovery time was affected (P < 0.05) by position: the quickest was lip (27 +/- 2 s), followed by ear (52 +/- 5 s) and armpit (78 +/- 7 s). In conclusion, taking into account retention and reading performances, injection of a 32-mm PIT into the armpit showed the best results on the farm, but a careful and longer recovery was needed in the abattoir. Improvement of recovery methodology and time would be necessary in order to recommend injection of PIT in the armpit instead of in the ear for cattle tracking or monitoring.

  7. Wideband energy reflectance findings in presence of normal tympanogram in children with Down's syndrome.

    PubMed

    Kaf, Wafaa A

    2011-02-01

    The prevalence of middle ear disorders in children with Down syndrome is higher than normal children due to the associated craniofacial abnormalities. The goal of this study is to evaluate middle ear function using wideband energy reflectance at ambient pressure in 14 young children with Down syndrome and matched control group (2½-5 years old; N=19 ears per group) who each have a normal 226Hz tympanogram. All children underwent otoscopic examination, hearing screening using play audiometry (500-4000Hz), and middle ear testing using 226Hz tympanometry and wideband energy reflectance. The chirp signals for the wideband energy reflectance were presented to the child's ear at 65dB SPL stimulus level and the recording was done over 220-8000Hz range. The measured energy reflectance represents the ratio of the sound energy reflected from the tympanic membrane to the incident sound energy transmitted to the middle ear at a specific frequency. Paired Samples t-test was computed for the mean, 95th, 75th, 25th, and 5th percentile data of each frequency of the two groups. Despite the presence of normal tympanometric findings in both groups, results revealed abnormal wideband energy reflectance findings in 63% of the children with Down syndrome compared to the normal wideband energy reflectance findings in the control group. The mean energy reflectance ratio of the Down syndrome group was abnormally lower than that of the control at 5700-8000Hz (p<0.0005). The 5th and 95th percentile ratios of the Down syndrome group fell outside the 5th and 95th percentile of the control group (p<0.0005). Abnormally low energy reflectance ratios above 4000Hz in the presence of normal tympanograms in the Down syndrome group may suggest associated congenital middle ear anomalies in children with DS. The present findings suggest that wideband energy reflectance has the potential to be of more practical value in children with DS than tympanometry. Further research with a larger number of Down syndrome children will illuminate the potential of wideband energy reflectance in diagnosing middle ear disorders in children with Down syndrome. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  8. Contralateral routing of signals disrupts monaural level and spectral cues to sound localisation on the horizontal plane.

    PubMed

    Pedley, Adam J; Kitterick, Pádraig T

    2017-09-01

    Contra-lateral routing of signals (CROS) devices re-route sound between the deaf and hearing ears of unilaterally-deaf individuals. This rerouting would be expected to disrupt access to monaural level cues that can support monaural localisation in the horizontal plane. However, such a detrimental effect has not been confirmed by clinical studies of CROS use. The present study aimed to exercise strict experimental control over the availability of monaural cues to localisation in the horizontal plane and the fitting of the CROS device to assess whether signal routing can impair the ability to locate sources of sound and, if so, whether CROS selectively disrupts monaural level or spectral cues to horizontal location, or both. Unilateral deafness and CROS device use were simulated in twelve normal hearing participants. Monaural recordings of broadband white noise presented from three spatial locations (-60°, 0°, and +60°) were made in the ear canal of a model listener using a probe microphone with and without a CROS device. The recordings were presented to participants via an insert earphone placed in their right ear. The recordings were processed to disrupt either monaural level or spectral cues to horizontal sound location by roving presentation level or the energy across adjacent frequency bands, respectively. Localisation ability was assessed using a three-alternative forced-choice spatial discrimination task. Participants localised above chance levels in all conditions. Spatial discrimination accuracy was poorer when participants only had access to monaural spectral cues compared to when monaural level cues were available. CROS use impaired localisation significantly regardless of whether level or spectral cues were available. For both cues, signal re-routing had a detrimental effect on the ability to localise sounds originating from the side of the deaf ear (-60°). CROS use also impaired the ability to use level cues to localise sounds originating from straight ahead (0°). The re-routing of sounds can restrict access to the monaural cues that provide a basis for determining sound location in the horizontal plane. Perhaps encouragingly, the results suggest that both monaural level and spectral cues may not be disrupted entirely by signal re-routing and that it may still be possible to reliably identify sounds originating on the hearing side. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  9. 15 CFR 30.1 - Purpose and definitions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... in place of a proof of filing citation when the AES or AESDirect computer systems experiences a major... goods and technologies; enforcing export control, antiboycott, and public safety laws; cooperating with... of the EAR. Supplement No. 2 to Part 774 of the EAR contains the General Technology and Software...

  10. 15 CFR 30.1 - Purpose and definitions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... in place of a proof of filing citation when the AES or AESDirect computer systems experiences a major... goods and technologies; enforcing export control, antiboycott, and public safety laws; cooperating with... of the EAR. Supplement No. 2 to Part 774 of the EAR contains the General Technology and Software...

  11. 15 CFR 30.1 - Purpose and definitions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... in place of a proof of filing citation when the AES or AESDirect computer systems experiences a major... goods and technologies; enforcing export control, antiboycott, and public safety laws; cooperating with... of the EAR. Supplement No. 2 to Part 774 of the EAR contains the General Technology and Software...

  12. 15 CFR 30.1 - Purpose and definitions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... in place of a proof of filing citation when the AES or AESDirect computer systems experiences a major... goods and technologies; enforcing export control, antiboycott, and public safety laws; cooperating with... of the EAR. Supplement No. 2 to Part 774 of the EAR contains the General Technology and Software...

  13. 15 CFR 30.1 - Purpose and definitions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... in place of a proof of filing citation when the AES or AESDirect computer systems experiences a major... goods and technologies; enforcing export control, antiboycott, and public safety laws; cooperating with... of the EAR. Supplement No. 2 to Part 774 of the EAR contains the General Technology and Software...

  14. Ear, Nose and Throat Foreign Bodies Removed under General Anaesthesia: A Retrospective Study.

    PubMed

    Shunyu, Neizekhotuo Brian; Akhtar, Hanifa; Karim, Habib Md Rezaul; Lyngdoh, Nari M; Yunus, Md; Jamil, Md

    2017-02-01

    For Otorhinolaryngologist, removal of Foreign Bodies (FB) from the ear, nose and throat is one of the common emergency procedures done. Most of the cases especially of the ear and nose can be managed without General Anaesthesia (GA). But in some cases GA may be needed. There are very few studies that address the scenario of ear, nose and throat foreign body that required GA for its removal and the complications associated with it. This study was conducted with the aim to study the patient's profile, types and distribution of FB removed under GA, and the associated complications. The present study is a hospital based retrospective, cross-sectional study conducted in the Department of Otorhinolaryngology in association with Department of Anaesthesiology and Critical Care in North Eastern Indira Gandhi Regional Institute of Health and Medical Sciences, Shillong, Meghalaya, India from year 2009 to 2014. Information was collected from indoor patient file and operation record book. Those patients where foreign body was not found after examination under GA were excluded. A total of 112 cases of foreign body in ear, nose and throat removed under GA were selected. There was variation of age from youngest case being 11 months to 74 years with a slight male predominance. Two third of the patients belonged to paediatric age group. Most of the FB were inanimate with high number of inorganic type found in majority. Foreign body in food passage was found in most cases. Coin and meat bone were the common FB in children and adults respectively. We found no complications related to removal of foreign body from the food passage and nose. But some complications were seen in foreign body of ear and tracheo-bronchial tree. Ear, nose and throat FB that required GA were seen in all age groups. FB of food passage constitute the majority. Type of foreign body varies between children and adults. In children most common types were related to toys and their part and food materials. In adults, food materials were most common.

  15. Using the Auditory Hazard Assessment Algorithm for Humans (AHAAH) Software, Beta Release W93e

    DTIC Science & Technology

    2009-09-01

    Hazard Assessment Algorithm for Humans (AHAAH) Does The AHAAH is an electro- acoustic model of the ear used to evaluate the hazard of impulse sounds...format is commonly used for recording music ; thus, these are typically stereo files and contain a “right” and a “left” channel as well as a header... acoustic data (sometimes deliberately induced in recording to maximize the digitizer’s dynamic range), it must be removed. When Set Baseline is

  16. The first record of a species of Perlidae from Jiangsu Province, China: a new species of Neoperla (Plecoptera: Perlidae).

    PubMed

    Chen, Zhi-Teng; Du, Yu-Zhou

    2015-06-23

    A new species of Neoperla (Plecoptera, Perlidae), N. jiangsuensis Chen & Du from Jiangsu Province, China, is described and illustrated. Neoperla jiangsuensis is characterized by the aedeagal sac with two C-shaped rows of large stout spines laterally, a patch of small spines, and with an apical double ear-shaped membranous lobes. The new species is the first recorded species of Perlidae known from the eastern coastal province of Jiangsu, China.

  17. Noise Attenuation Loss Due to Wearing APEL Eye Protection with Ear-Muff Style Headset Systems

    DTIC Science & Technology

    2012-02-14

    USAARL Report No. 2012-09 Noise Attenuation Loss Due to Wearing APEL Eye Protection with Ear-Muff Style Headset Systems By Efrem Reeves Elmaree...Cameron Station, Alexandria, Virginia 22314. Orders will be expedited if placed through the librarian or other person designated to request...not be construed as an official Department of the Army position, policy, or decision, unless so designated by other official documentation. Citation

  18. Emergency Victim Care. A Training Manual for Emergency Medical Technicians. Module 10. Injuries of the Eye, Ear, Nose, Abdomen, Central Nervous System and Genitalia. Burns and Environmental Injuries. Revised.

    ERIC Educational Resources Information Center

    Ohio State Dept. of Education, Columbus. Div. of Vocational Education.

    This training manual for emergency medical technicians, one of 14 modules that comprise the Emergency Victim Care textbook, covers injuries of the eyes, ears, nose, abdomen, central nervous system (CNS), and genitalia; burns; and environmental injuries. Objectives stated for the two chapters are for the student to be able to describe procedures…

  19. Role of mantle flow in Nubia-Somalia plate divergence

    NASA Astrophysics Data System (ADS)

    Stamps, D. S.; Iaffaldano, G.; Calais, E.

    2015-01-01

    Present-day continental extension along the East African Rift System (EARS) has often been attributed to diverging sublithospheric mantle flow associated with the African Superplume. This implies a degree of viscous coupling between mantle and lithosphere that remains poorly constrained. Recent advances in estimating present-day opening rates along the EARS from geodesy offer an opportunity to address this issue with geodynamic modeling of the mantle-lithosphere system. Here we use numerical models of the global mantle-plates coupled system to test the role of present-day mantle flow in Nubia-Somalia plate divergence across the EARS. The scenario yielding the best fit to geodetic observations is one where torques associated with gradients of gravitational potential energy stored in the African highlands are resisted by weak continental faults and mantle basal drag. These results suggest that shear tractions from diverging mantle flow play a minor role in present-day Nubia-Somalia divergence.

  20. Congenital atresia of the external ear and tinnitus: a new syndrome.

    PubMed

    Shulman, Abraham; Strashun, Arnold M; Goldstein, Barbara; Lenhardt, Martin L

    2006-01-01

    Congenital atresia of the external ears and severe tinnitus has been reported by two patients to be contralateral to the atretic ear. The use of the nuclear medicine imaging technique of single-photon emission computed tomography (SPECT) of brain has demonstrated hypoperfusion in brain areas supplied by the middle cerebral artery on the side of the atretic ear. Ultrahigh-frequency audiometry (UHFA) has revealed a bilateral loss of hearing greater than expected for the age of affected patients. Quantitative electroencephalography (QEEG) has shown a significant central nervous system electrical dysfunction correlated with the SPECT of brain findings. One case is reported in detail at this time. Completion of the medical audiological tinnitus patient protocol, including SPECT of brain, UHFA, and QEEG, accurately established the clinical tinnitus diagnosis of predominantly a central-type tinnitus, a clinical hypothesis that the medical significance of the tinnitus is a "soft" sign of cerebrovascular disease, and provided a rationale for treatment directed to a presumed ischemia of brain based on a receptor-targeted therapy targeted to the GABA-A receptor, resulting in significant tinnitus relief. Questions that have arisen include (1) the incidence of occurrence of hypoperfusion of the middle cerebral artery in congenital atresia patients; (2) implications and long-term consequences of this finding in this patient population for development of cerebrovascular disease; (3) brain plasticity for tinnitus relief (i.e., neuronal reprogramming, particularly in response to treatment recommendations for complaints of the cochleovestibular system in general and specifically for tinnitus); (4) the clinical significance of the UHFA thresholds of bilateral hearing loss greater than expected for the age of the patient; and (5) whether congenital atresia of the external ear may be part of a syndrome that includes hypoperfusion in brain areas supplied by the middle cerebral artery on the side of the atretic ear, ultra-high-frequency bilateral loss of hearing greater than expected for the age of the patient, and significant central nervous system electrical dysfunction. As far as we can determine, these findings, highlighted by the brain SPECT, have not previously been reported in patients with congenital atresia of the external ear.

  1. Use and selection of bridges as day roosts by Rafinesque's Big Eared Bats.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bennett, Frances, M.; Loeb, Susan, C.; Bunch, Mary, S.

    ABSTRACT.—Rafinesque’s big-eared bats (Corynorhinus rafinesquii) use bridges as day roosts in parts of their range, but information on bridge use across their range is lacking. From May to Aug. 2002 we surveyed 1129 bridges (12.5%) within all 46 counties of South Carolina to determine use and selection of bridges as day roosts by big-eared bats and to document their distribution across the state. During summer 2003, we visited 235 bridges in previously occupied areas of the state to evaluate short-term fidelity to bridge roosts. We found colonies and solitary big-eared bats beneath 38 bridges in 2002 and 54 bridges inmore » 2003. Construction type and size of bridges strongly influenced use in both years; bats selected large, concrete girder bridges and avoided flat-bottomed slab bridges. The majority of occupied bridges (94.7%) were in the Upper and Lower Coastal Plains, but a few bridges (5.3%) were located in the Piedmont. Rafinesque’s big-eared bats were absent beneath bridges in the Blue Ridge Mountains. We established new records of occurrence for 10 counties. In the Coastal Plains, big-eared bats exhibited a high degree of short-term fidelity to roosts in highway bridges. For bridges that were occupied at least once, mean frequency of use was 65.9%. Probability of finding bats under a bridge ranged from 0.46 to 0.73 depending on whether the bridge was occupied in the previous year. Thus, bridges should be inspected three to five times in a given year to determine whether they are being used. Regional bridge roost surveys may be a good method for determining the distribution of C. rafinesquii, particularly in the Coastal Plains, and protection of suitable bridges may be a viable conservation strategy where natural roost sites are limited.« less

  2. Effects of venting on wind noise levels measured at the eardrum.

    PubMed

    Chung, King

    2013-01-01

    Wind noise can be a nuisance to hearing aid users. With the advent of sophisticated feedback reduction algorithms, people with higher degrees of hearing loss are fit with larger vents than previously allowed, and more people with lesser degrees of hearing loss are fit with open hearing aids. The purpose of this study was to examine the effects of venting on wind noise levels in the ear canal for hearing aids with omnidirectional and directional microphones. Two behind-the-ear hearing aids were programmed when they were worn on a Knowles Electronics Manikin for Acoustic Research. The hearing aid worn on the right ear was programmed to the omnidirectional microphone mode and the one on the left to the directional microphone mode. The hearing aids were adjusted to linear amplification with flat frequency response in an anechoic chamber. Gains below 10 dB were used to avoid output limiting of wind noise levels at low input levels. Wind noise samples were recorded at the eardrum location in a wind tunnel at wind velocities ranging from a gentle to a strong breeze. The hearing aids were coupled to #13 tubings (i.e., open vent), or conventional skeleton earmolds with no vent, pressure vents, or 3mm vents. Polar and spectral characteristics of wind noise were analyzed off-line using MatLab programs. Wind noise levels in the ear canals were mostly predicted by vent-induced frequency response changes in the conventional earmold conditions for both omnidirectional and directional hearing aids. The open vent condition, however, yielded the lowest levels, which could not be entirely predicted by the frequency response changes of the hearing aids. This indicated that a wind-related vent effect permitted an additional amount of sound reduction in the ear canal, which could not be explained by known vent effects. For the microphone location, form factor, and gain settings tested, open fit hearing aids yielded lower noise levels at the eardrum location than conventional behind-the-ear hearing aids.

  3. Comparison of manual versus semiautomatic milk recording systems in dairy goats.

    PubMed

    Ait-Saidi, A; Caja, G; Carné, S; Salama, A A K; Ghirardi, J J

    2008-04-01

    A total of 24 Murciano-Granadina dairy goats in early-midlactation were used to compare the labor time and data collection efficiency of using manual (M) vs. semiautomated (SA) systems for milk recording. Goats were milked once daily in a 2 x 12 parallel platform, with 6 milking units on each side. The M system used visual identification (ID) by large plastic ear tags, on-paper data recording, and data manually uploaded to a computer. The SA system used electronic ID, automatic ID, manual data recording on reader keyboard, and automatic data uploading to computer by Bluetooth connection. Data were collected for groups of 2 x 12 goats for 15 test days of each system during a period of 70 d. Time data were converted to a decimal scale. No difference in milk recording time between M and SA (1.32 +/- 0.03 and 1.34 +/- 0.03 min/goat, respectively) was observed. Time needed for transferring data to the computer was greater for M when compared with SA (0.20 +/- 0.01 and 0.05 +/- 0.01 min/goat). Overall milk recording time was greater in M than in SA (1.52 +/- 0.04 vs. 1.39 +/- 0.04 min/goat), the latter decreasing with operator training. Time for transferring milk recording data to the computer was 4.81 +/- 0.34 and 1.09 +/- 0.10 min for M and SA groups of 24 goats, respectively, but only increased by 0.19 min in SA for each additional 24 goats. No difference in errors of data acquisition was detected between M and SA systems during milk recording (0.6%), but an additional 1.1% error was found in the M system during data uploading. Predicted differences between M and SA increased with the number of goats processed on the test-day. Reduction in labor time cost ranged from euro0.5 to 12.9 (US$0.7 to 17.4) per milk recording, according to number of goats from 24 to 480 goats and accounted for 40% of the electronic ID costs. In conclusion, electronic ID was more efficient for labor costs and resulted in fewer data errors, the benefit being greater with trained operators and larger goat herds.

  4. Acoustical transmission-line model of the middle-ear cavities and mastoid air cells.

    PubMed

    Keefe, Douglas H

    2015-04-01

    An acoustical transmission line model of the middle-ear cavities and mastoid air cell system (MACS) was constructed for the adult human middle ear with normal function. The air-filled cavities comprised the tympanic cavity, aditus, antrum, and MACS. A binary symmetrical airway branching model of the MACS was constructed using an optimization procedure to match the average total volume and surface area of human temporal bones. The acoustical input impedance of the MACS was calculated using a recursive procedure, and used to predict the input impedance of the middle-ear cavities at the location of the tympanic membrane. The model also calculated the ratio of the acoustical pressure in the antrum to the pressure in the middle-ear cavities at the location of the tympanic membrane. The predicted responses were sensitive to the magnitude of the viscothermal losses within the MACS. These predicted input impedance and pressure ratio functions explained the presence of multiple resonances reported in published data, which were not explained by existing MACS models.

  5. Developmental evolutionary biology of the vertebrate ear: conserving mechanoelectric transduction and developmental pathways in diverging morphologies

    NASA Technical Reports Server (NTRS)

    Fritzsch, B.; Beisel, K. W.; Bermingham, N. A.

    2000-01-01

    This brief overview shows that a start has been made to molecularly dissect vertebrate ear development and its evolutionary conservation to the development of the insect hearing organ. However, neither the patterning process of the ear nor the patterning process of insect sensory organs is sufficiently known at the moment to provide more than a first glimpse. Moreover, hardly anything is known about otocyst development of the cephalopod molluscs, another triploblast lineage that evolved complex 'ears'. We hope that the apparent conserved functional and cellular components present in the ciliated sensory neurons/hair cells will also be found in the genes required for vertebrate ear and insect sensory organ morphogenesis (Fig. 3). Likewise, we expect that homologous pre-patterning genes will soon be identified for the non-sensory cell development, which is more than a blocking of neuronal development through the Delta/Notch signaling system. Generation of the apparently unique ear could thus represent a multiplication of non-sensory cells by asymmetric and symmetric divisions as well as modification of existing patterning process by implementing novel developmental modules. In the final analysis, the vertebrate ear may come about by increasing the level of gene interactions in an already existing and highly conserved interactive cascade of bHLH genes. Since this was apparently achieved in all three lineages of triploblasts independently (Fig. 3), we now need to understand how much of the morphogenetic cascades are equally conserved across phyla to generate complex ears. The existing mutations in humans and mice may be able to point the direction of future research to understand the development of specific cell types and morphologies in the formation of complex arthropod, cephalopod, and vertebrate 'ears'.

  6. Characterizing the ear canal acoustic reflectance and impedance by pole-zero fitting

    PubMed Central

    Robinson, Sarah R.; Nguyen, Cac T.; Allen, Jont B.

    2013-01-01

    This study characterizes middle ear complex acoustic reflectance (CAR) and impedance by fitting poles and zeros to real-ear measurements. The goal of this work is to establish a quantitative connection between pole-zero locations and the underlying physical properties of CAR data. Most previous studies have analyzed CAR magnitude; while the magnitude accounts for reflected power, it does not encode latency information. Thus, an analysis that studies the real and imaginary parts of the data together could be more powerful. Pole-zero fitting of CAR data is examined using data compiled from various studies, dating back to Voss and Allen (1994). Recent CAR measurements were taken using a middle ear acoustic power analyzer (MEPA) system (HearID, Mimosa Acoustics), which makes complex acoustic impedance and reflectance measurements in the ear canal over the 0.2 to 6.0 kHz frequency range. Pole-zero fits to measurements over this range are achieved with an average RMS relative error of less than 3% using 12 poles. Factoring the reflectance fit into its all-pass and minimum-phase components approximates the effect of the ear canal, allowing for comparison across measurements. It was found that individual CAR magnitude variations for normal middle ears in the 1 to 4 kHz range often give rise to closely-placed pole-zero pairs, and that the locations of the poles and zeros in the s-plane may differ between normal and pathological middle ears. This study establishes a methodology for examining the physical and mathematical properties of CAR using a concise parametric model. Pole-zero modeling shows promise for precise parameterization of CAR data and for identification of middle ear pathologies. PMID:23524141

  7. Estrus synchronization in sheep with synthetic progestagens.

    PubMed

    Awel, Hayatu; Eshetu, Lisanework; Tadesse, Gebrehiwot; Birhanu, Alemselam; Khar, S K

    2009-10-01

    Sixteen female sheep of Degua breed were assigned to receive either the full dose of norgestomet ear implant and injectable solution containing norgestomet and estradiol valerate (n = 8) or half the dose (n = 8). The ear implants were removed in both groups on day 12. All ewes received an intramuscular administration of 500 IU PMSG at implant withdrawal. Synchronized ewes were individually hand mated twice at 48 and 60 hours after implant removal. One ewe in each group however refused mating on both occasions. Pregnancy diagnosis was conducted by bimanual external palpation 90 to 100 days post mating. The conception rates (3/7, 42.85%) and (5/7, 71.42%) were recorded in the two treatment groups, respectively. All eight ewes lambed between 145 to 153 days post mating. In group I ewes carried only singletons (prolificity rate 1.0) whereas in group II two ewes delivered twins, producing 7 lambs with prolificity rate of 1.4 (N.S). From this preliminary investigation it appears that the lower dose of norgestomet ear implants offers better option for estrus synchronization accompanied by higher fertility.

  8. Association between heart rhythm and cortical sound processing.

    PubMed

    Marcomini, Renata S; Frizzo, Ana Claúdia F; de Góes, Viviane B; Regaçone, Simone F; Garner, David M; Raimundo, Rodrigo D; Oliveira, Fernando R; Valenti, Vitor E

    2018-04-26

    Sound signal processing signifies an important factor for human conscious communication and it may be assessed through cortical auditory evoked potentials (CAEP). Heart rate variability (HRV) provides information about heart rate autonomic regulation. We investigated the association between resting HRV and CAEP. We evaluated resting HRV in the time and frequency domain and the CAEP components. The subjects remained at rest for 10 minutes for HRV recording, then they performed the CAEP examinations through frequency and duration protocols in both ears. Linear regression indicated that the amplitude of the N2 wave of the CAEP in the left ear (not right ear) was significantly influenced by standard deviation of normal-to-normal RR-intervals (17.7%) and percentage of adjacent RR-intervals with a difference of duration greater than 50 milliseconds (25.3%) time domain HRV indices in the frequency protocol. In the duration protocol and in the left ear the latency of the P2 wave was significantly influenced by low (LF) (20.8%) and high frequency (HF) bands in normalized units (21%) and LF/HF ratio (22.4%) indices of HRV spectral analysis. The latency of the N2 wave was significantly influenced by LF (25.8%), HF (25.9%) and LF/HF (28.8%). In conclusion, we promote the supposition that resting heart rhythm is associated with thalamo-cortical, cortical-cortical and auditory cortex pathways involved with auditory processing in the right hemisphere.

  9. Ear Structures of the Naked Mole-Rat, Heterocephalus glaber, and Its Relatives (Rodentia: Bathyergidae)

    PubMed Central

    Mason, Matthew J.; Cornwall, Hannah L.; Smith, Ewan St. J.

    2016-01-01

    Although increasingly popular as a laboratory species, very little is known about the peripheral auditory system of the naked mole-rat, Heterocephalus glaber. In this study, middle and inner ears of naked mole-rats of a range of ages were examined using micro-computed tomography and dissection. The ears of five other bathyergid species (Bathyergus suillus, Cryptomys hottentotus, Fukomys micklemi, Georychus capensis and Heliophobius argenteocinereus) were examined for comparative purposes. The middle ears of bathyergids show features commonly found in other members of the Ctenohystrica rodent clade, including a fused malleus and incus, a synovial stapedio-vestibular articulation and the loss of the stapedius muscle. Heterocephalus deviates morphologically from the other bathyergids examined in that it has a more complex mastoid cavity structure, poorly-ossified processes of the malleus and incus, a ‘columelliform’ stapes and fewer cochlear turns. Bathyergids have semicircular canals with unusually wide diameters relative to their radii of curvature. How the lateral semicircular canal reaches the vestibule differs between species. Heterocephalus has much more limited high-frequency hearing than would be predicted from its small ear structures. The spongy bone forming its ossicular processes, the weak incudo-stapedial articulation, the columelliform stapes and (compared to other bathyergids) reduced cochlear coiling are all potentially degenerate features which might reflect a lack of selective pressure on its peripheral auditory system. Substantial intraspecific differences were found in certain middle and inner ear structures, which might also result from relaxed selective pressures. However, such interpretations must be treated with caution in the absence of experimental evidence. PMID:27926945

  10. A prediction of the minke whale (Balaenoptera acutorostrata) middle-ear transfer function.

    PubMed

    Tubelli, Andrew A; Zosuls, Aleks; Ketten, Darlene R; Yamato, Maya; Mountain, David C

    2012-11-01

    The lack of baleen whale (Cetacea Mysticeti) audiograms impedes the assessment of the impacts of anthropogenic noise on these animals. Estimates of audiograms, which are difficult to obtain behaviorally or electrophysiologically for baleen whales, can be made by simulating the audiogram as a series of components representing the outer, middle, and inner ear (Rosowski, 1991; Ruggero and Temchin, 2002). The middle-ear portion of the system can be represented by the middle-ear transfer function (METF), a measure of the transmission of acoustic energy from the external ear to the cochlea. An anatomically accurate finite element model of the minke whale (Balaenoptera acutorostrata) middle ear was developed to predict the METF for a mysticete species. The elastic moduli of the auditory ossicles were measured by using nanoindentation. Other mechanical properties were estimated from experimental stiffness measurements or from published values. The METF predicted a best frequency range between approximately 30 Hz and 7.5 kHz or between 100 Hz and 25 kHz depending on stimulation location. Parametric analysis found that the most sensitive parameters are the elastic moduli of the glove finger and joints and the Rayleigh damping stiffness coefficient β. The predicted hearing range matches well with the vocalization range.

  11. Isolation of sphere-forming stem cells from the mouse inner ear.

    PubMed

    Oshima, Kazuo; Senn, Pascal; Heller, Stefan

    2009-01-01

    The mammalian inner ear has very limited ability to regenerate lost sensory hair cells. This deficiency becomes apparent when hair cell loss leads to hearing loss as a result of either ototoxic insult or the aging process. Coincidently, with this inability to regenerate lost hair cells, the adult cochlea does not appear to harbor cells with a proliferative capacity that could serve as progenitor cells for lost cells. In contrast, adult mammalian vestibular sensory epithelia display a limited ability for hair cell regeneration, and sphere-forming cells with stem cell features can be isolated from the adult murine vestibular system. The neonatal inner ear, however, does harbor sphere-forming stem cells residing in cochlear and vestibular tissues. Here, we provide protocols to isolate sphere-forming stem cells from neonatal vestibular and cochlear sensory epithelia as well as from the spiral ganglion. We further describe procedures for sphere propagation, cell differentiation, and characterization of inner ear cell types derived from spheres. Sphere-forming stem cells from the mouse inner ear are an important tool for the development of cellular replacement strategies of damaged inner ears and are a bona fide progenitor cell source for transplantation studies.

  12. Whole-mount Confocal Microscopy for Adult Ear Skin: A Model System to Study Neuro-vascular Branching Morphogenesis and Immune Cell Distribution.

    PubMed

    Yamazaki, Tomoko; Li, Wenling; Mukouyama, Yoh-Suke

    2018-03-29

    Here, we present a protocol of a whole-mount adult ear skin imaging technique to study comprehensive three-dimensional neuro-vascular branching morphogenesis and patterning, as well as immune cell distribution at a cellular level. The analysis of peripheral nerve and blood vessel anatomical structures in adult tissues provides some insights into the understanding of functional neuro-vascular wiring and neuro-vascular degeneration in pathological conditions such as wound healing. As a highly informative model system, we have focused our studies on adult ear skin, which is readily accessible for dissection. Our simple and reproducible protocol provides an accurate depiction of the cellular components in the entire skin, such as peripheral nerves (sensory axons, sympathetic axons, and Schwann cells), blood vessels (endothelial cells and vascular smooth muscle cells), and inflammatory cells. We believe this protocol will pave the way to investigate morphological abnormalities in peripheral nerves and blood vessels as well as the inflammation in the adult ear skin under different pathological conditions.

  13. Auditory Brainstem Circuits That Mediate the Middle Ear Muscle Reflex

    PubMed Central

    Mukerji, Sudeep; Windsor, Alanna Marie; Lee, Daniel J.

    2010-01-01

    The middle ear muscle (MEM) reflex is one of two major descending systems to the auditory periphery. There are two middle ear muscles (MEMs): the stapedius and the tensor tympani. In man, the stapedius contracts in response to intense low frequency acoustic stimuli, exerting forces perpendicular to the stapes superstructure, increasing middle ear impedance and attenuating the intensity of sound energy reaching the inner ear (cochlea). The tensor tympani is believed to contract in response to self-generated noise (chewing, swallowing) and nonauditory stimuli. The MEM reflex pathways begin with sound presented to the ear. Transduction of sound occurs in the cochlea, resulting in an action potential that is transmitted along the auditory nerve to the cochlear nucleus in the brainstem (the first relay station for all ascending sound information originating in the ear). Unknown interneurons in the ventral cochlear nucleus project either directly or indirectly to MEM motoneurons located elsewhere in the brainstem. Motoneurons provide efferent innervation to the MEMs. Although the ascending and descending limbs of these reflex pathways have been well characterized, the identity of the reflex interneurons is not known, as are the source of modulatory inputs to these pathways. The aim of this article is to (a) provide an overview of MEM reflex anatomy and physiology, (b) present new data on MEM reflex anatomy and physiology from our laboratory and others, and (c) describe the clinical implications of our research. PMID:20870664

  14. Hemispheric asymmetry of auditory steady-state responses to monaural and diotic stimulation.

    PubMed

    Poelmans, Hanne; Luts, Heleen; Vandermosten, Maaike; Ghesquière, Pol; Wouters, Jan

    2012-12-01

    Amplitude modulations in the speech envelope are crucial elements for speech perception. These modulations comprise the processing rate at which syllabic (~3-7 Hz), and phonemic transitions occur in speech. Theories about speech perception hypothesize that each hemisphere in the auditory cortex is specialized in analyzing modulations at different timescales, and that phonemic-rate modulations of the speech envelope lateralize to the left hemisphere, whereas right lateralization occurs for slow, syllabic-rate modulations. In the present study, neural processing of phonemic- and syllabic-rate modulations was investigated with auditory steady-state responses (ASSRs). ASSRs to speech-weighted noise stimuli, amplitude modulated at 4, 20, and 80 Hz, were recorded in 30 normal-hearing adults. The 80 Hz ASSR is primarily generated by the brainstem, whereas 20 and 4 Hz ASSRs are mainly cortically evoked and relate to speech perception. Stimuli were presented diotically (same signal to both ears) and monaurally (one signal to the left or right ear). For 80 Hz, diotic ASSRs were larger than monaural responses. This binaural advantage decreased with decreasing modulation frequency. For 20 Hz, diotic ASSRs were equal to monaural responses, while for 4 Hz, diotic responses were smaller than monaural responses. Comparison of left and right ear stimulation demonstrated that, with decreasing modulation rate, a gradual change from ipsilateral to right lateralization occurred. Together, these results (1) suggest that ASSR enhancement to binaural stimulation decreases in the ascending auditory system and (2) indicate that right lateralization is more prominent for low-frequency ASSRs. These findings may have important consequences for electrode placement in clinical settings, as well as for the understanding of low-frequency ASSR generation.

  15. The Correlation Between Pre and Postoperative Hearing Level with High Resolution Computed Tomography (HRCT) Findings in Congenital Canal Atresia (CAA) Patients.

    PubMed

    Asma, A; Abdul Fatah, A W; Hamzaini, A H; Mazita, A

    2013-12-01

    In managing patient with congenital congenital aural atresia (CAA), preoperative high resolution computed tomography (HRCT) scan and hearing assessment are important. A grading system based on HRCT findings was first introduced by Jahrsdoefer in order to select appropriate candidates for operation and to predict the postoperative hearing outcome in CAA patients. The score of eight and more was considered as a good prognostic factor for hearing reconstruction surgery. However previously in our center this score was not used as the criteria for surgical procedure. This study was conducted at Center A to evaluate the correlation between pre and postoperative hearing level with HRCT based on a Jahrsdoefer grading system in patients with CAA. All records and HRCT films with CAA from January 1997 until December 2007 at Center A were evaluated. The demographic data, operative records, pre and post operative hearing levels and HRCT findings were analyzed. Hearing level in this study was based on a pure tone average of air-bone gap at 500 Hz, 1 kHz and 2 kHz or hearing level obtained from auditory brainstem response eudiometry. This study was approved by Research Ethics Committee (code number, FF-197-2008). Thirty-two ears were retrospectively evaluated. The postoperative hearing level of 30 dB and less was considered as successful hearing result postoperatively. Of the six ears which underwent canalplasty, three had achieved successful hearing result. However, there was no significant correlation between preoperative hearing level (HL) with HRCT score and postoperative HL with HRCT score at 0.05 significant levels (correlation coefficient = -0.292, P = 0.105 and correlation coefficient = -0.127, P = 0.810) respectively. Hearing evaluation and HRCT temporal bone are two independent evaluations for the patients with CAA before going for hearing reconstructive surgery.

  16. Optoelectronic holographic otoscope for measurement of nano-displacements in tympanic membranes

    PubMed Central

    Hernández-Montes, Maria del Socorro; Furlong, Cosme; Rosowski, John J.; Hulli, Nesim; Harrington, Ellery; Cheng, Jeffrey Tao; Ravicz, Michael E.; Santoyo, Fernando Mendoza

    2009-01-01

    Current methodologies for characterizing tympanic membrane (TM) motion are usually limited to either average acoustic estimates (admittance or reflectance) or single-point mobility measurements, neither of which suffices to characterize the detailed mechanical response of the TM to sound. Furthermore, while acoustic and single-point measurements may aid in diagnosing some middle-ear disorders, they are not always useful. Measurements of the motion of the entire TM surface can provide more information than these other techniques and may be superior for diagnosing pathology. This paper presents advances in our development of a new compact optoelectronic holographic otoscope (OEHO) system for full-field-of-view characterization of nanometer scale sound-induced displacements of the surface of the TM at video rates. The OEHO system consists of a fiber optic subsystem, a compact otoscope head, and a high-speed image processing computer with advanced software for recording and processing holographic images coupled to a computer-controlled sound-stimulation and recording system. A prototype OEHO system is in use in a medical-research environment to address basic-science questions regarding TM function. The prototype provides real-time observation of sound-induced TM displacement patterns over a broad-frequency range. Representative time-averaged and stroboscopic holographic interferometry results in animals and cadaveric human samples are shown, and their potential utility discussed. PMID:19566316

  17. Optoelectronic holographic otoscope for measurement of nano-displacements in tympanic membranes

    NASA Astrophysics Data System (ADS)

    Del Socorro Hernández-Montes, Maria; Furlong, Cosme; Rosowski, John J.; Hulli, Nesim; Harrington, Ellery; Cheng, Jeffrey Tao; Ravicz, Michael E.; Santoyo, Fernando Mendoza

    2009-05-01

    Current methodologies for characterizing tympanic membrane (TM) motion are usually limited to either average acoustic estimates (admittance or reflectance) or single-point mobility measurements, neither of which suffices to characterize the detailed mechanical response of the TM to sound. Furthermore, while acoustic and single-point measurements may aid in diagnosing some middle-ear disorders, they are not always useful. Measurements of the motion of the entire TM surface can provide more information than these other techniques and may be superior for diagnosing pathology. We present advances in our development of a new compact optoelectronic holographic otoscope (OEHO) system for full field-of-view characterization of nanometer-scale sound-induced displacements of the TM surface at video rates. The OEHO system consists of a fiber optic subsystem, a compact otoscope head, and a high-speed image processing computer with advanced software for recording and processing holographic images coupled to a computer-controlled sound-stimulation and recording system. A prototype OEHO system is in use in a medical research environment to address basic science questions regarding TM function. The prototype provides real-time observation of sound-induced TM displacement patterns over a broad frequency range. Representative time-averaged and stroboscopic holographic interferometry results in animals and human cadaver samples are shown, and their potential utility is discussed.

  18. Neural and receptor cochlear potentials obtained by transtympanic electrocochleography in auditory neuropathy.

    PubMed

    Santarelli, Rosamaria; Starr, Arnold; Michalewski, Henry J; Arslan, Edoardo

    2008-05-01

    Transtympanic electrocochleography (ECochG) was recorded bilaterally in children and adults with auditory neuropathy (AN) to evaluate receptor and neural generators. Test stimuli were clicks from 60 to 120dB p.e. SPL. Measures obtained from eight AN subjects were compared to 16 normally hearing children. Receptor cochlear microphonics (CMs) in AN were of normal or enhanced amplitude. Neural compound action potentials (CAPs) and receptor summating potentials (SPs) were identified in five AN ears. ECochG potentials in those ears without CAPs were of negative polarity and of normal or prolonged duration. We used adaptation to rapid stimulus rates to distinguish whether the generators of the negative potentials were of neural or receptor origin. Adaptation in controls resulted in amplitude reduction of CAP twice that of SP without affecting the duration of ECochG potentials. In seven AN ears without CAP and with prolonged negative potential, adaptation was accompanied by reduction of both amplitude and duration of the negative potential to control values consistent with neural generation. In four ears without CAP and with normal duration potentials, adaptation was without effect consistent with receptor generation. In five AN ears with CAP, there was reduction in amplitude of CAP and SP as controls but with a significant decrease in response duration. Three patterns of cochlear potentials were identified in AN: (1) presence of receptor SP without CAP consistent with pre-synaptic disorder of inner hair cells; (2) presence of both SP and CAP consistent with post-synaptic disorder of proximal auditory nerve; (3) presence of prolonged neural potentials without a CAP consistent with post-synaptic disorder of nerve terminals. Cochlear potential measures may identify pre- and post-synaptic disorders of inner hair cells and auditory nerves in AN.

  19. Quality of Life and Hearing Eight Years After Sudden Sensorineural Hearing Loss.

    PubMed

    Härkönen, Kati; Kivekäs, Ilkka; Rautiainen, Markus; Kotti, Voitto; Vasama, Juha-Pekka

    2017-04-01

    To explore long-term hearing results, quality of life (QoL), quality of hearing (QoH), work-related stress, tinnitus, and balance problems after idiopathic sudden sensorineural hearing loss (ISSNHL). Cross-sectional study. We reviewed the audiograms of 680 patients with unilateral ISSNHL on average 8 years after the hearing impairment, and then divided the patients into two study groups based on whether their ISSNHL had recovered to normal (pure tone average [PTA] ≤ 30 dB) or not (PTA > 30 dB). The inclusion criteria were a hearing threshold decrease of 30 dB or more in at least three contiguous frequencies occurring within 72 hours in the affected ear and normal hearing in the contralateral ear. Audiograms of 217 patients fulfilled the criteria. We reviewed their medical records; measured present QoL, QoH, and work-related stress with specific questionnaires; and updated the hearing status. Poor hearing outcome after ISSNHL was correlated with age, severity of hearing loss, and vertigo together with ISSNHL. Quality of life and QoH were statistically significantly better in patients with recovered hearing, and the patients had statistically significantly less tinnitus and balance problems. During the 8-year follow-up, the PTA of the affected ear deteriorated on average 7 dB, and healthy ear deteriorated 6 dB. Idiopathic sudden sensorineural hearing loss that failed to recover had a negative impact on long-term QoL and QoH. The hearing deteriorated as a function of age similarly both in the affected and the healthy ear, and there were no differences between the groups. The cumulative recurrence rate for ISSNHL was 3.5%. 4 Laryngoscope, 127:927-931, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  20. Bacterial invasion of the inner ear in association with pneumococcal meningitis.

    PubMed

    Møller, Martin Nue; Brandt, Christian; Østergaard, Christian; Caye-Thomasen, Per

    2014-06-01

    To examine the pathways of bacterial invasion and subsequent spreading in the inner ear during pneumococcal meningitis. A well-established adult rat model of Streptococcus pneumoniae meningitis was used. Thirty rats were inoculated intrathecally with S. pneumoniae serotype 1, 3 or 9 V and received no additional treatment. The rats were sacrificed when reaching terminal illness or on Day 7 and then prepared for serial sectioning and PAS-Alcian blue staining for light microscopy. During the first few days after inoculation, bacteria invade the inner ear through the cochlear aqueduct, into the scala tympani of the cochlea (perilymphatic space). From here, bacteria spreads apically toward the helicotrema and subsequently basally through the scala vestibuli, toward the vestibule and the vestibular system. When the bacteria after 5 to 6 days had reached scala vestibuli of the basal turn of the cochlea, hematogenous spreading occurred to the spiral ligament and into the cochlear endolymph, subsequently to the vestibular endolymph. We found no evidence of alternative routes for bacterial invasion in the inner ear. Several internal barriers to bacterial spreading were found within the inner ear. Bacterial elimination was evidenced by engulfment by macrophages within the inner ear. From the meninges, pneumococci invade the inner ear through the cochlear aqueduct during the first days of infection, whereas hematogenous invasion via the spiral ligament capillary bed occur at later stages. Although internal barriers exist within the inner ear, the spreading of bacteria occurs via the natural pathways of the fluid compartments. Bacterial elimination occurs by local macrophage engulfment.

  1. The LuxS/AI-2 Quorum-Sensing System of Streptococcus pneumoniae Is Required to Cause Disease, and to Regulate Virulence- and Metabolism-Related Genes in a Rat Model of Middle Ear Infection.

    PubMed

    Yadav, Mukesh K; Vidal, Jorge E; Go, Yoon Y; Kim, Shin H; Chae, Sung-Won; Song, Jae-Jun

    2018-01-01

    Objective: Streptococcus pneumoniae colonizes the nasopharynx of children, and from nasopharynx it could migrate to the middle ear and causes acute otitis media (AOM). During colonization and AOM, the pneumococcus forms biofilms. In vitro biofilm formation requires a functional LuxS/AI-2 quorum-sensing system. We investigated the role of LuxS/AI-2 signaling in pneumococcal middle ear infection, and identified the genes that are regulated by LuxS/AI-2 during pneumococcal biofilm formation. Methods: Streptococcus pneumoniae D39 wild-type and an isogenic D39Δ luxS strain were utilized to evaluate in vitro biofilm formation, and in vivo colonization and epithelial damage using a microtiter plate assay and a rat model of pneumococcal middle ear infection, respectively. Biofilm structures and colonization and epithelial damage were evaluated at the ultrastructural level by scanning electron microscopy and confocal microscopy. Microarrays were used to investigate the global genes that were regulated by LuxS/AI-2 during biofilm formation. Results: The biofilm biomass and density of D39Δ luxS were significantly ( p < 0.05) lower than those of D39 wild-type. SEM and confocal microscopy revealed that D39Δ luxS formed thin biofilms in vitro compared with D39 wild-type. The in vivo model of middle ear infection showed that D39Δ luxS resulted in ~60% less ( p < 0.05) bacterial colonization than the wild-type. SEM analysis of the rat middle ears revealed dense biofilm-like cell debris deposited on the cilia in wild-type D39-infected rats. However, little cell debris was deposited in the middle ears of the D39Δ luxS -inoculated rats, and the cilia were visible. cDNA-microarray analysis revealed 117 differentially expressed genes in D39Δ luxS compared with D39 wild-type. Among the 66 genes encoding putative proteins and previously characterized proteins, 60 were significantly downregulated, whereas 6 were upregulated. Functional annotation revealed that genes involved in DNA replication and repair, ATP synthesis, capsule biosynthesis, cell division, the cell cycle, signal transduction, transcription regulation, competence, virulence, and carbohydrate metabolism were downregulated in the absence of LuxS/AI-2. Conclusion: The S. pneumoniae LuxS/AI-2 quorum-sensing system is necessary for biofilm formation and the colonization of the ear epithelium, and caused middle ear infection in the rat model. LuxS/AI-2 regulates the expression of the genes involved in virulence and bacterial fitness during pneumococcal biofilm formation.

  2. New Protocol for Skin Landmark Registration in Image-Guided Neurosurgery: Technical Note.

    PubMed

    Gerard, Ian J; Hall, Jeffery A; Mok, Kelvin; Collins, D Louis

    2015-09-01

    Newer versions of the commercial Medtronic StealthStation allow the use of only 8 landmark pairs for patient-to-image registration as opposed to 9 landmarks in older systems. The choice of which landmark pair to drop in these newer systems can have an effect on the quality of the patient-to-image registration. To investigate 4 landmark registration protocols based on 8 landmark pairs and compare the resulting registration accuracy with a 9-landmark protocol. Four different protocols were tested on both phantoms and patients. Two of the protocols involved using 4 ear landmarks and 4 facial landmarks and the other 2 involved using 3 ear landmarks and 5 facial landmarks. Both the fiducial registration error and target registration error were evaluated for each of the different protocols to determine any difference between them and the 9-landmark protocol. No difference in fiducial registration error was found between any of the 8-landmark protocols and the 9-landmark protocol. A significant decrease (P < .05) in target registration error was found when using a protocol based on 4 ear landmarks and 4 facial landmarks compared with the other protocols based on 3 ear landmarks. When using 8 landmarks to perform the patient-to-image registration, the protocol using 4 ear landmarks and 4 facial landmarks greatly outperformed the other 8-landmark protocols and 9-landmark protocol, resulting in the lowest target registration error.

  3. PubMed Central

    LINKE, R.; LEICHTLE, A.; SHEIKH, F.; SCHMIDT, C.; FRENZEL, H.; GRAEFE, H.; WOLLENBERG, B.; MEYER, J.E.

    2013-01-01

    SUMMARY Surgery on the temporal bone is technically challenging due to its complex anatomy. Precise anatomical dissection of the human temporal bone is essential and is fundamental for middle ear surgery. We assessed the possible application of a virtual reality temporal bone surgery simulator to the education of ear surgeons. Seventeen ENT physicians with different levels of surgical training and 20 medical students performed an antrotomy with a computer-based virtual temporal bone surgery simulator. The ease, accuracy and timing of the simulated temporal bone surgery were assessed using the automatic assessment software provided by the simulator device and additionally with a modified Final Product Analysis Scale. Trained ENT surgeons, physicians without temporal bone surgical training and medical students were all able to perform the antrotomy. However, the highly trained ENT surgeons were able to complete the surgery in approximately half the time, with better handling and accuracy as assessed by the significant reduction in injury to important middle ear structures. Trained ENT surgeons achieved significantly higher scores using both dissection analysis methods. Surprisingly, there were no significant differences in the results between medical students and physicians without experience in ear surgery. The virtual temporal bone training system can stratify users of known levels of experience. This system can be used not only to improve the surgical skills of trained ENT surgeons for more successful and injury-free surgeries, but also to train inexperienced physicians/medical students in developing their surgical skills for the ear. PMID:24043916

  4. Recent inner ear specialization for high-speed hunting in cheetahs.

    PubMed

    Grohé, Camille; Lee, Beatrice; Flynn, John J

    2018-02-02

    The cheetah, Acinonyx jubatus, is the fastest living land mammal. Because of its specialized hunting strategy, this species evolved a series of specialized morphological and functional body features to increase its exceptional predatory performance during high-speed hunting. Using high-resolution X-ray computed micro-tomography (μCT), we provide the first analyses of the size and shape of the vestibular system of the inner ear in cats, an organ essential for maintaining body balance and adapting head posture and gaze direction during movement in most vertebrates. We demonstrate that the vestibular system of modern cheetahs is extremely different in shape and proportions relative to other cats analysed (12 modern and two fossil felid species), including a closely-related fossil cheetah species. These distinctive attributes (i.e., one of the greatest volumes of the vestibular system, dorsal extension of the anterior and posterior semicircular canals) correlate with a greater afferent sensitivity of the inner ear to head motions, facilitating postural and visual stability during high-speed prey pursuit and capture. These features are not present in the fossil cheetah A. pardinensis, that went extinct about 126,000 years ago, demonstrating that the unique and highly specialized inner ear of the sole living species of cheetah likely evolved extremely recently, possibly later than the middle Pleistocene.

  5. Interfacing a biosurveillance portal and an international network of institutional analysts to detect biological threats.

    PubMed

    Riccardo, Flavia; Shigematsu, Mika; Chow, Catherine; McKnight, C Jason; Linge, Jens; Doherty, Brian; Dente, Maria Grazia; Declich, Silvia; Barker, Mike; Barboza, Philippe; Vaillant, Laetitia; Donachie, Alastair; Mawudeku, Abla; Blench, Michael; Arthur, Ray

    2014-01-01

    The Early Alerting and Reporting (EAR) project, launched in 2008, is aimed at improving global early alerting and risk assessment and evaluating the feasibility and opportunity of integrating the analysis of biological, chemical, radionuclear (CBRN), and pandemic influenza threats. At a time when no international collaborations existed in the field of event-based surveillance, EAR's innovative approach involved both epidemic intelligence experts and internet-based biosurveillance system providers in the framework of an international collaboration called the Global Health Security Initiative, which involved the ministries of health of the G7 countries and Mexico, the World Health Organization, and the European Commission. The EAR project pooled data from 7 major internet-based biosurveillance systems onto a common portal that was progressively optimized for biological threat detection under the guidance of epidemic intelligence experts from public health institutions in Canada, the European Centre for Disease Prevention and Control, France, Germany, Italy, Japan, the United Kingdom, and the United States. The group became the first end users of the EAR portal, constituting a network of analysts working with a common standard operating procedure and risk assessment tools on a rotation basis to constantly screen and assess public information on the web for events that could suggest an intentional release of biological agents. Following the first 2-year pilot phase, the EAR project was tested in its capacity to monitor biological threats, proving that its working model was feasible and demonstrating the high commitment of the countries and international institutions involved. During the testing period, analysts using the EAR platform did not miss intentional events of a biological nature and did not issue false alarms. Through the findings of this initial assessment, this article provides insights into how the field of epidemic intelligence can advance through an international network and, more specifically, how it was further developed in the EAR project.

  6. Interfacing a Biosurveillance Portal and an International Network of Institutional Analysts to Detect Biological Threats

    PubMed Central

    Shigematsu, Mika; Chow, Catherine; McKnight, C. Jason; Linge, Jens; Doherty, Brian; Dente, Maria Grazia; Declich, Silvia; Barker, Mike; Barboza, Philippe; Vaillant, Laetitia; Donachie, Alastair; Mawudeku, Abla; Blench, Michael; Arthur, Ray

    2014-01-01

    The Early Alerting and Reporting (EAR) project, launched in 2008, is aimed at improving global early alerting and risk assessment and evaluating the feasibility and opportunity of integrating the analysis of biological, chemical, radionuclear (CBRN), and pandemic influenza threats. At a time when no international collaborations existed in the field of event-based surveillance, EAR's innovative approach involved both epidemic intelligence experts and internet-based biosurveillance system providers in the framework of an international collaboration called the Global Health Security Initiative, which involved the ministries of health of the G7 countries and Mexico, the World Health Organization, and the European Commission. The EAR project pooled data from 7 major internet-based biosurveillance systems onto a common portal that was progressively optimized for biological threat detection under the guidance of epidemic intelligence experts from public health institutions in Canada, the European Centre for Disease Prevention and Control, France, Germany, Italy, Japan, the United Kingdom, and the United States. The group became the first end users of the EAR portal, constituting a network of analysts working with a common standard operating procedure and risk assessment tools on a rotation basis to constantly screen and assess public information on the web for events that could suggest an intentional release of biological agents. Following the first 2-year pilot phase, the EAR project was tested in its capacity to monitor biological threats, proving that its working model was feasible and demonstrating the high commitment of the countries and international institutions involved. During the testing period, analysts using the EAR platform did not miss intentional events of a biological nature and did not issue false alarms. Through the findings of this initial assessment, this article provides insights into how the field of epidemic intelligence can advance through an international network and, more specifically, how it was further developed in the EAR project. PMID:25470464

  7. Human auditory steady state responses to binaural and monaural beats.

    PubMed

    Schwarz, D W F; Taylor, P

    2005-03-01

    Binaural beat sensations depend upon a central combination of two different temporally encoded tones, separately presented to the two ears. We tested the feasibility to record an auditory steady state evoked response (ASSR) at the binaural beat frequency in order to find a measure for temporal coding of sound in the human EEG. We stimulated each ear with a distinct tone, both differing in frequency by 40Hz, to record a binaural beat ASSR. As control, we evoked a beat ASSR in response to both tones in the same ear. We band-pass filtered the EEG at 40Hz, averaged with respect to stimulus onset and compared ASSR amplitudes and phases, extracted from a sinusoidal non-linear regression fit to a 40Hz period average. A 40Hz binaural beat ASSR was evoked at a low mean stimulus frequency (400Hz) but became undetectable beyond 3kHz. Its amplitude was smaller than that of the acoustic beat ASSR, which was evoked at low and high frequencies. Both ASSR types had maxima at fronto-central leads and displayed a fronto-occipital phase delay of several ms. The dependence of the 40Hz binaural beat ASSR on stimuli at low, temporally coded tone frequencies suggests that it may objectively assess temporal sound coding ability. The phase shift across the electrode array is evidence for more than one origin of the 40Hz oscillations. The binaural beat ASSR is an evoked response, with novel diagnostic potential, to a signal that is not present in the stimulus, but generated within the brain.

  8. Morbidity and outcomes of foreign travelers in Zakynthos island, Greece: a retrospective study.

    PubMed

    Plessa, Eleni; Tansarli, Giannoula S; Xanthopoulos, Dimitrios; Falagas, Matthew E

    2014-01-01

    Although there is satisfactory recording of diseases affecting travelers visiting developing countries, little is known regarding morbidity of travelers when visiting developed countries. We sought to evaluate the morbidity of foreign travelers in Zakynthos, a popular Greek island attracting large number of foreign tourists every summer. Data from foreign travelers that accommodated in Zakynthos and sought medical services from the private offices of Zante Medical Care from May 1 to October 30 2012 were retrospectively analyzed. Two thousand six hundred and eighty-eight patients were included in the study. The mean age (± SD) of the patients whom the age was recorded was 29.6 (± 18.3) and 51.5% of them were from 18 to 40 years old. Disorders of the respiratory tract (32.7%), dermatologic conditions (21.1%), musculoskeletal injuries (16.4%), and gastrointestinal disorders (16.3%) were the four most prevalent clinical categories among patients. Ear disorder was the most common syndromic description (14.5%) among which 81.2% were ear infections; otitis externa and otitis media were diagnosed in 8.5% and 3.3% patients in total. The most common specific diagnosis was gastroenteritis (14.3%). Insect bite and sunburn were the most common diagnosis (6.5% and 3.8%, respectively) among patients with a dermatologic condition. Ear infection was the most common diagnosis in pediatric patients. Disorders mainly of the upper respiratory tract were the predominant causes of illness among foreign travelers in Zakynthos. Traveler's diarrhea was the most common specific diagnosis but the prevalence within the total population was not very high.

  9. [Reference values for the vestibulo-ocular reflex response to the head shaking and the bithermal caloric tests].

    PubMed

    Molina, M I; Zapata, C; Palma, M J; López-Escámez, J A

    2006-01-01

    To obtain reference values for the vestibulo-ocular reflex response to the head-shaking nystagmus and the bithermal caloric test in the spanish population. A descriptive study. SET UP: General hospital. One hundred and seven healthy sex and age stratified voluntiers were included. The final sample included 97 individuals over 18 years of age. Spontaneous nystagmus (SN), head-shaking nystagmus (HSN) and caloric induced nystagmus were explored. The eyes movement was recorded by a video-oculographic system. The SN or HSN was considered significant when at least 6 consecutive beats with a slow phase velocity of 2 degrees/sec were detected. The caloric test was performed with water flow at 250mL/20 s at 30 degrees C and 44 degrees C with an interval of 10 minutes between irrigations. The percentage of canal paresis (CP) and directional preponderance (DP) was calculated using maximum slow phase velocity and the Jongkees index formula. Presence of SN, horizontal and vertical SHN, percentage of CP and DP. SN was found in 10,3% individuals (6 women and 4 men). Horizontal HSN was also observed in 9 women and 10 men (19,5%), and vertical HSN in 8 women and 10 men (18,6%). The mean and 95 percentil for CP were 13,10 and 28,60 in women and 11,02 and 27,30 in men. For DP, the mean and 95 percentil were 11,76 and 35,80 in women and 11,58 and 28,65 in men. The 5 percentils for slow phase velocity of nystagmus after each irrigation were 6,30; 5,14; 5,96; 4,02 degrees/s (left ear 44 degrees, right ear 44 degrees, left ear 30 degrees, right ear 30 degrees, respectively) in the group of women; and 5,82; 6,99; 5,67; 4,55 degrees/s in men (with the same irrigation sequence). Results presented should be considered as a population-based norms and may be useful as references for water bithermal test for VOG studies. The SN or HSN could be observed in subjects without vestibular pathology.

  10. 32 CFR 250.9 - Notice to accompany the dissemination of export-controlled technical data.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Commerce for items controlled by the Export Administration Regulations (EAR), may constitute a violation of..., the penalty for unlawful export of items or information controlled under the EAR is a fine of up to $1... resulting from manufacture or use for any purpose of any product, article, system, or material involving...

  11. 32 CFR 250.9 - Notice to accompany the dissemination of export-controlled technical data.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Commerce for items controlled by the Export Administration Regulations (EAR), may constitute a violation of..., the penalty for unlawful export of items or information controlled under the EAR is a fine of up to $1... resulting from manufacture or use for any purpose of any product, article, system, or material involving...

  12. 32 CFR 250.9 - Notice to accompany the dissemination of export-controlled technical data.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Commerce for items controlled by the Export Administration Regulations (EAR), may constitute a violation of..., the penalty for unlawful export of items or information controlled under the EAR is a fine of up to $1... resulting from manufacture or use for any purpose of any product, article, system, or material involving...

  13. 32 CFR 250.9 - Notice to accompany the dissemination of export-controlled technical data.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Commerce for items controlled by the Export Administration Regulations (EAR), may constitute a violation of..., the penalty for unlawful export of items or information controlled under the EAR is a fine of up to $1... resulting from manufacture or use for any purpose of any product, article, system, or material involving...

  14. The MIT Lincoln Laboratory RT-04F Diarization Systems: Applications to Broadcast Audio and Telephone Conversations

    DTIC Science & Technology

    2004-11-01

    this paper we describe the systems developed by MITLL and used in DARPA EARS Rich Transcription Fall 2004 (RT-04F) speaker diarization evaluation...many types of audio sources, the focus if the DARPA EARS project and the NIST Rich Transcription evaluations is primarily speaker diarization ...present or samples of any of the speakers . An overview of the general diarization problem and approaches can be found in [1]. In this paper, we

  15. Understanding the translocation mechanism of PLGA nanoparticles across round window membrane into the inner ear: a guideline for inner ear drug delivery based on nanomedicine

    PubMed Central

    Zhang, Liping; Xu, Yuan; Cao, Wenjuan; Xie, Shibao; Wen, Lu; Chen, Gang

    2018-01-01

    Background The round window membrane (RWM) functions as the primary biological barrier for therapeutic agents in the inner ear via local application. Previous studies on inner ear nano-drug delivery systems mostly focused on their pharmacokinetics and distribution in the inner ear, but seldom on the interaction with the RWM. Clarifying the transport mechanism of nanoparticulate carriers across RWM will shed more light on the optimum design of nano-drug delivery systems intended for meeting demands for their clinical application. Methods The poly (lactic-co-glycolic acid) nanoparticles (PLGA NPs) encapsulating coumarin-6 were prepared by emulsifying solvent evaporation method. We utilized confocal laser scanning microscope (CLSM) in combination with transmission electron microscope to investigate the transport pathway of PLGA NPs in the RWM. Simultaneously, the concentration and time dependence of NPs across the RWM were also determined. The endocytic mechanism of NPs through this membrane interface was classically analyzed by means of various endocytic inhibitors. The intracellular location of NPs into lysosomes was evaluated using CLSM scanning microscope colocalization analysis. The Golgi-related inhibitors were employed to probe into the function of Golgi and endoplasmic reticulum (ER) in the discharge of NPs out of cells. Results PLGA NPs were herein transported through the RWM of a sandwich-like structure into the perilymph via the transcellular pathway. NPs were internalized predominantly via macropinocytosis and caveolin-mediated endocytic pathways. After being internalized, the endocytosed cargos were entrapped within the lysosomal compartments and/or the endoplasmic reticulum/Golgi apparatus which mediated the exocytotic release of NPs. Conclusion For the first time, we showed the translocation itinerary of NPs in RWM, providing a guideline for the rational fabrication of inner ear nanoparticulate carriers with better therapeutic effects. PMID:29403277

  16. Routine activities and emotion in the life of dairy cows: Integrating body language into an affective state framework

    PubMed Central

    de Oliveira, Daiana

    2018-01-01

    We assessed dairy cows’ body postures while they were performing different stationary activities in a loose housing system and then used the variation within and between individuals to identify potential connections between specific postures and the valence and arousal dimensions of emotion. We observed 72 individuals within a single milking herd focusing on their ear, neck and tail positions while they were: feeding from individual roughage bins, being brushed by a mechanical rotating brush and queuing to enter a single automatic milking system. Cows showed different ear, neck and tail postures depending on the situation. When combined, their body posture during feeding was ears back up and neck down, with tail wags directed towards the body, during queuing their ears were mainly axial and forward, their neck below the horizontal and the tail hanging stationary, and during brushing their ears were backwards and asymmetric, the neck horizontal and the tail wagging vigorously. We then placed these findings about cow body posture during routine activities into an arousal/valence framework used in animal emotion research (dimensional model of core affect). In this way we generate a priori predictions of how the positions of the ears, neck and tail of cows may change in other situations, previously demonstrated to vary in valence and arousal. We propose that this new methodology, with its different steps of integration, could contribute to the identification and validation of behavioural (postural) indicators of how positively or negatively cows experience other activities, or situations, and how calm or aroused they are. Although developed here on dairy cattle, by focusing on relevant postures, this approach could be easily adapted to other species. PMID:29718937

  17. Optimal Electromechanical Reshaping of the Auricular Ear and Long-term Outcomes in an In Vivo Rabbit Model

    PubMed Central

    Manuel, Cyrus T.; Tjoa, Tjoson; Nguyen, Tony; Su, Erica; Wong, Brian J. F.

    2016-01-01

    IMPORTANCE The prominent ear is a common external ear anomaly that is usually corrected through surgery. Electromechanical reshaping (EMR) may provide the means to reshape cartilage through the use of direct current (in milliamperes) applied percutaneously with needle electrodes and thus to reduce reliance on open surgery. OBJECTIVE To determine the long-term outcomes (shape change, cell viability, and histology) of a more refined EMR voltage and time settings for reshaping rabbit auricle. DESIGN, SETTING, AND SUBJECTS The intact ears of 14 New Zealand white rabbits were divided into 2 groups. Group 1 received 4 V for 5 minutes (5 ears), 5 V for 4 minutes (5 ears), or no voltage for 5 minutes (control; 4 ears). Group 2 received an adjusted treatment of 4 V for 4 minutes (7 ears) or 5 V for 3 minutes (7 ears). A custom mold with platinum electrodes was used to bend the pinna and to perform EMR. Pinnae were splinted for 6 months along the region of the bend. Rabbits were killed humanely and the ears were harvested the day after splint removal. Data were collected from March 14, 2013, to July 8, 2014, and analyzed from August 29, 2013, to March 1, 2015. MAIN OUTCOMES AND MEASURES Bend angle and mechanical behavior via palpation were recorded through photography and videography. Tissue was sectioned for histologic examination and confocal microscopy to assess changes to microscopic structure and cell viability. RESULTS Rabbits ranged in age from 6 to 8 months and weighed 3.8 to 4.0 g. The mean (SD) bend angles were 81° (45°) for the controls and, in the 5 EMR groups, 72° (29°) for 4 V for 4 minutes, 101° (19°) for 4 V for 5 minutes, 78° (18°) for 5 V for 3 minutes, and 126° (21°) for 5 V for 4 minutes. At 5 V, an increase in application time from 3 to 4 minutes provided significant shape change (78° [18°] and 126° [21°], respectively; P = .003). Pinnae stained with hematoxylin-eosin displayed localized areas of cell injury and fibrosis in and around electrode insertion sites. This circumferential zone of injury (range, 1.3–2.1 mm) corresponded to absence of red florescence on the cell viability assay. CONCLUSIONS AND RELEVANCE In this in vivo study, EMR produces shape changes in the intact pinnae of rabbits. A short application of 4 V or 5 V can achieve adequate reshaping of the pinnae. Tissue injury around the electrodes is modest in spatial distribution. This study provides a more optimal set of EMR variables and a critical step toward evaluation of EMR in clinical trials. LEVEL OF EVIDENCE NA. PMID:27101542

  18. A tympanal insect ear exploits a critical oscillator for active amplification and tuning.

    PubMed

    Mhatre, Natasha; Robert, Daniel

    2013-10-07

    A dominant theme of acoustic communication is the partitioning of acoustic space into exclusive, species-specific niches to enable efficient information transfer. In insects, acoustic niche partitioning is achieved through auditory frequency filtering, brought about by the mechanical properties of their ears. The tuning of the antennal ears of mosquitoes and flies, however, arises from active amplification, a process similar to that at work in the mammalian cochlea. Yet, the presence of active amplification in the other type of insect ears--tympanal ears--has remained uncertain. Here we demonstrate the presence of active amplification and adaptive tuning in the tympanal ear of a phylogenetically basal insect, a tree cricket. We also show that the tree cricket exploits critical oscillator-like mechanics, enabling high auditory sensitivity and tuning to conspecific songs. These findings imply that sophisticated auditory mechanisms may have appeared even earlier in the evolution of hearing and acoustic communication than currently appreciated. Our findings also raise the possibility that frequency discrimination and directional hearing in tympanal systems may rely on physiological nonlinearities, in addition to mechanical properties, effectively lifting some of the physical constraints placed on insects by their small size [6] and prompting an extensive reexamination of invertebrate audition. Copyright © 2013 The Authors. Published by Elsevier Inc. All rights reserved.

  19. A prediction of the minke whale (Balaenoptera acutorostrata) middle-ear transfer functiona)

    PubMed Central

    Tubelli, Andrew A.; Zosuls, Aleks; Ketten, Darlene R.; Yamato, Maya; Mountain, David C.

    2012-01-01

    The lack of baleen whale (Cetacea Mysticeti) audiograms impedes the assessment of the impacts of anthropogenic noise on these animals. Estimates of audiograms, which are difficult to obtain behaviorally or electrophysiologically for baleen whales, can be made by simulating the audiogram as a series of components representing the outer, middle, and inner ear (Rosowski, 1991; Ruggero and Temchin, 2002). The middle-ear portion of the system can be represented by the middle-ear transfer function (METF), a measure of the transmission of acoustic energy from the external ear to the cochlea. An anatomically accurate finite element model of the minke whale (Balaenoptera acutorostrata) middle ear was developed to predict the METF for a mysticete species. The elastic moduli of the auditory ossicles were measured by using nanoindentation. Other mechanical properties were estimated from experimental stiffness measurements or from published values. The METF predicted a best frequency range between approximately 30 Hz and 7.5 kHz or between 100 Hz and 25 kHz depending on stimulation location. Parametric analysis found that the most sensitive parameters are the elastic moduli of the glove finger and joints and the Rayleigh damping stiffness coefficient β. The predicted hearing range matches well with the vocalization range. PMID:23145610

  20. Visualization of human inner ear anatomy with high-resolution MR imaging at 7T: initial clinical assessment.

    PubMed

    van der Jagt, M A; Brink, W M; Versluis, M J; Steens, S C A; Briaire, J J; Webb, A G; Frijns, J H M; Verbist, B M

    2015-02-01

    In many centers, MR imaging of the inner ear and auditory pathway performed on 1.5T or 3T systems is part of the preoperative work-up of cochlear implants. We investigated the applicability of clinical inner ear MR imaging at 7T and compared the visibility of inner ear structures and nerves within the internal auditory canal with images acquired at 3T. Thirteen patients with sensorineural hearing loss eligible for cochlear implantation underwent examinations on 3T and 7T scanners. Two experienced head and neck radiologists evaluated the 52 inner ear datasets. Twenty-four anatomic structures of the inner ear and 1 overall score for image quality were assessed by using a 4-point grading scale for the degree of visibility. The visibility of 11 of the 24 anatomic structures was rated higher on the 7T images. There was no significant difference in the visibility of 13 anatomic structures and the overall quality rating. A higher incidence of artifacts was observed in the 7T images. The gain in SNR at 7T yielded a more detailed visualization of many anatomic structures, especially delicate ones, despite the challenges accompanying MR imaging at a high magnetic field. © 2015 by American Journal of Neuroradiology.

  1. Vestibular signals in primate cortex for self-motion perception.

    PubMed

    Gu, Yong

    2018-04-21

    The vestibular peripheral organs in our inner ears detect transient motion of the head in everyday life. This information is sent to the central nervous system for automatic processes such as vestibulo-ocular reflexes, balance and postural control, and higher cognitive functions including perception of self-motion and spatial orientation. Recent neurophysiological studies have discovered a prominent vestibular network in the primate cerebral cortex. Many of the areas involved are multisensory: their neurons are modulated by both vestibular signals and visual optic flow, potentially facilitating more robust heading estimation through cue integration. Combining psychophysics, computation, physiological recording and causal manipulation techniques, recent work has addressed both the encoding and decoding of vestibular signals for self-motion perception. Copyright © 2018. Published by Elsevier Ltd.

  2. Enhancing Ear and Hearing Health Access for Children With Technology and Connectivity.

    PubMed

    Swanepoel, De Wet

    2017-10-12

    Technology and connectivity advances are demonstrating increasing potential to improve access of service delivery to persons with hearing loss. This article demonstrates use cases from community-based hearing screening and automated diagnosis of ear disease. This brief report reviews recent evidence for school- and home-based hearing testing in underserved communities using smartphone technologies paired with calibrated headphones. Another area of potential impact facilitated by technology and connectivity is the use of feature extraction algorithms to facilitate automated diagnosis of most common ear conditions from video-otoscopic images. Smartphone hearing screening using calibrated headphones demonstrated equivalent sensitivity and specificity for school-based hearing screening. Automating test sequences with a forced-choice response paradigm allowed persons with minimal training to offer screening in underserved communities. The automated image analysis and diagnosis system for ear disease demonstrated an overall accuracy of 80.6%, which is up to par and exceeds accuracy rates previously reported for general practitioners and pediatricians. The emergence of these tools that capitalize on technology and connectivity advances enables affordable and accessible models of service delivery for community-based ear and hearing care.

  3. Multi-emitter laser multiplexer using a two-mirror beam shaper

    NASA Astrophysics Data System (ADS)

    Cobb, Joshua M.; Brennan, John; Bhatia, Vikram

    2014-12-01

    A system was designed and built to spatially multiplex four broad area laser diodes (BALD) and condense the light into a multi-mode fiber with a core diameter of 105 um and an NA of 0.15. The lasers were efficiently combined with an étendue aspect ratio scaler (EARS) optic. The EARS works under the principle of a two mirror beam shaper. We were able to successfully couple more than 87% of the optical energy into the fiber. The design of the optical system and the results of several built systems are discussed.

  4. Effectiveness of Ear Splint Therapy for Ear Deformities

    PubMed Central

    2017-01-01

    Objective To present our experience with ear splint therapy for babies with ear deformities, and thereby demonstrate that this therapy is an effective and safe intervention without significant complications. Methods This was a retrospective study of 54 babies (35 boys and 19 girls; 80 ears; age ≤3 months) with ear deformities who had received ear splint therapy at the Center for Torticollis, Department of Physical Medicine and Rehabilitation, Ajou University Hospital between December 2014 and February 2016. Before the initiation of ear splint therapy, ear deformities were classified with reference to the standard terminology. We compared the severity of ear deformity before and after ear splint therapy by using the physician's ratings. We also compared the physician's ratings and the caregiver's ratings on completion of ear splint therapy. Results Among these 54 babies, 41 children (58 ears, 72.5%) completed the ear splint therapy. The mean age at initiation of therapy was 52.91±18.26 days and the treatment duration was 44.27±32.06 days. Satyr ear, forward-facing ear lobe, Darwinian notch, overfolded ear, and cupped ear were the five most common ear deformities. At the completion of therapy, the final physician's ratings of ear deformities were significantly improved compared to the initial ratings (8.28±1.44 vs. 2.51±0.92; p<0.001). There was no significant difference between the physician's ratings and the caregiver's ratings at the completion of ear splint therapy (8.28±1.44 vs. 8.0±1.61; p=0.297). Conclusion We demonstrated that ear splint therapy significantly improved ear deformities in babies, as measured by quantitative rating scales. Ear splint therapy is an effective and safe intervention for babies with ear deformities. PMID:28289646

  5. Morphological effects of nanosecond- and femtosecond-pulsed laser ablation on human middle ear ossicles

    NASA Astrophysics Data System (ADS)

    Ilgner, Justus F.; Wehner, Martin; Lorenzen, Johann; Bovi, Manfred; Westhofen, Martin

    2004-07-01

    Introduction: Since the early 1980's, a considerable number of different laser systems have been introduced into reconstructive middle ear surgery. Depending on the ablation mode, however, pressure transients or thermal load to inner ear structures continue to be subject to discussion. Material and methods: We examined single spot ablations by a nanosecond-pulsed, frequency-tripled Nd:YAG-Laser (355 nm, beam diameter 10 μm, pulse rate 2 kHz, power 250 mW) on isolated human mallei. In a second set-up, a similar system (355 nm, beam diameter 20 μm, pulse rate 10 kHz, power 160-1500 mW) was coupled to a scanner to examine the morphology of bone surface ablation over an area of 1mm2. A third set-up employed a femtosecond-pulsed CrLiSAF-Oscillator (850 nm, pulse duration 100 fs, pulse energy 40μJ, beam diameter 36 μm, pulse rate 1 kHz) to compare these results with the former and with those obtained from a commercially available Er:YAG laser for ear surgery (Zeiss ORL E, 2940 nm, single pulse, energy 10-25 mJ). Results: In set-up 1 and 2, thermal effects in terms of marginal carbonization were visible in all single spot ablations of 1 s and longer. With ablations of 0.5 seconds, precise cutting margins with preservation of surrounding tissue could be observed. Cooling with saline solution resulted in no carbonization at 1500 mW and a scan speed of 500 mm/s. Set-up 3 equally showed no carbonization, although scanning times were longer and ablation less pronounced. Conclusion: Ultrashort pulsed laser systems could potentially aid further refinement of reconstructive microsurgery of the middle ear.

  6. A New Way for Antihelixplasty in Prominent Ear Surgery: Modified Postauricular Fascial Flap.

    PubMed

    Taş, Süleyman; Benlier, Erol

    2016-06-01

    Otoplasty procedures aim to reduce the concha-mastoid angle and recreate the antihelical fold. Here, we explained the modified postauricular fascial flap, described as a new way for recreating the antihelical fold, and reported the results of patients on whom this flap was used. The defined technique was used on 24 patients (10 females and 14 males; age, 6-27 years; mean, 16.7 years) between June 2009 and July 2012, a total of 48 procedures in total (bilateral). Follow-up ranged from 1 to 3 years (mean, 1.5 years). At the preoperative and postoperative time points (1 and 12 months after surgery), all patients were measured for upper and middle helix-head distance and were photographed. The records were analyzed statistically using t test and analysis of variance. The procedure resulted in ears that were natural in appearance without any significant visible evidence of surgery. The operations resulted in no complications except 1 patient who developed a small skin ulcer on the left ear because of band pressure. When we compared the preoperative and postoperative upper and middle helix-head distance, there was a high significance statistically. To introduce modified postauricular fascial flap, we used a simple and safe procedure to recreate an antihelical fold. This procedure led to several benefits, including a natural-in-appearance antihelical fold, prevention of suture extrusion and granuloma, as well as minimized risk for recurrence due to neochondrogenesis. This method may be used as a standard procedure for treating prominent ears surgically.

  7. The Influence of Early Ophthalmic Hospitals on the Journal.

    PubMed

    Pathipati, Akhilesh S; Tsai, James C

    2018-05-09

    To consider the American Journal of Ophthalmology's (AJO's) role not only as a forum to describe clinical and scientific advances but also as a record of institutional histories. We used the New York Eye and Ear Infirmary of Mount Sinai, the Massachusetts Eye and Ear Infirmary, and the Wills Eye Hospital as case studies on the Journal's role in documenting the people and organizations that have moved ophthalmology forward. Perspective. Using the ScienceDirect database, we conducted a literature search to gather all mentions of the 3 eye hospitals in the Journal's archives from 1918 to 2018. We evaluated those search results to identify a few of the individuals and articles that highlight how the history of eye institutions are reflected in the AJO. Searches for the aforementioned 3 hospitals yielded over 3400 results in Journal archives. These included articles on their histories, proceedings from clinical case conferences, profiles of prominent surgeons, and information about educational offerings, among others. Many of those articles were written by physicians from those institutions who also served on the AJO's editorial board or had a long history of publishing in the Journal. The AJO has played a crucial role in the last 100 years as a register of ophthalmic history. The New York Eye and Ear Infirmary of Mount Sinai, Massachusetts Eye and Ear Infirmary, and Wills Eye Hospital provide 3 examples of how that role manifests. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. Strategies of immunization against mucosal infections.

    PubMed

    Russell, M W; Martin, M H; Wu, H Y; Hollingshead, S K; Moldoveanu, Z; Mestecky, J

    2000-12-08

    The presence of secretory (S-) IgA in middle-ear fluid and localization of IgA-secreting cells in its mucosae suggest that the middle ear is an effector site of the mucosal immune system. Several strategies have been devised to induce potent, long-lasting, and recallable mucosal S-IgA antibodies, as well as circulating IgG antibodies and Th1- or Th2-type help, according to the most appropriate responses for a particular infection. Application of immunogens to inductive sites in the upper respiratory tract may be most effective for generating responses in the middle ear and nasopharynx for protection against the organisms responsible for otitis media.

  9. Investigation of a broadband duct noise control system inspired by the middle ear mechanism

    NASA Astrophysics Data System (ADS)

    Wang, Chunqi; Huang, Lixi

    2012-08-01

    A new duct noise control device is introduced based on the mechanism of human middle ear which functions as a compact, broadband impedance transformer between the air motion in the outer ear and the liquid motion in the inner ear. The system consists of two rigid endplates, simulating the tympanic membrane and the stapes footplate, and they are connected by a single rigid rod, simulating the overall action of the ossicular chain. These three pieces are placed in a side-branch cavity, and the whole device is called an ossicular silencer. A specific configuration is investigated numerically with a two-dimensional finite element model. Results show that broadband noise attenuation can be achieved in the very low frequency regime. Typically, two or more resonance peaks are found and the transmission loss between two neighbouring peaks is maintained at a high level. The cavity length is found to be the most crucial parameter that determines the effective frequency range of the ossicular silencer. The total cavity volume, which is a major controlling factor in most existing noise control devices, becomes less influential. The fluid medium in the enclosed cavity mainly acts like an added mass, while its stiffness effect is negligible. Simplified plane wave analysis is also conducted to reveal the mechanisms of the system resonances. The first resonance is identified as of the mass-spring system with mass contributions from both fluid and the plates, while the second one is of the Herschel-Quincke (HQ) tube resonance.

  10. Red ear syndrome precipitated by a dietary trigger: a case report

    PubMed Central

    2014-01-01

    Introduction Red ear syndrome is a rare condition characterized by episodic attacks of erythema of the ear accompanied by burning ear pain. Symptoms are brought on by touch, exertion, heat or cold, stress, neck movements and washing or brushing of hair. Diagnosis and treatment of this condition are challenging. The case we report here involves a woman whose symptoms were brought on by a dietary trigger: orange juice as well as stress, causing significant physical and psychological morbidity. Avoidance of triggers resulted in symptomatic improvement. Case presentation A 22-year-old Caucasian woman who was a student presented twice to our department with evolving symptoms, the first time with hyperacusis (abnormal sound sensitivity arising from within the auditory system to sounds of moderate volume), intermittent right tinnitus and subjective hearing difficulties. She presented five years later with highly distressing episodes of erythematous ears, which were associated with burning pain around the ear and temporal areas, and intolerance to noise. After keeping a symptom diary, she identified orange juice and stress as triggers of her symptoms. No local head and neck pathology was present. Investigations and imaging were negative. Avoidance of triggers led to great symptomatic improvement. To the best of our knowledge, dietary triggers have not previously been reported as a trigger for this syndrome. This case shows a direct temporal link to a dietary trigger and supports a primary pathogenesis. Recognition and management of primary headache disorder and simple dietary and lifestyle changes brought about symptomatic relief. Conclusion Red ear syndrome is a little-known clinical syndrome of unknown etiology and management. To the best of our knowledge, our present case report is the first to describe primary red ear syndrome triggered by orange juice. Clinical benefit derived from avoidance of this trigger, which is already known to precipitate migraines, gives some insight into the pathogenesis of red ear syndrome. PMID:25303997

  11. Changes in immunostaining of inner ears after antigen challenge into the scala tympani.

    PubMed

    Ichimiya, I; Kurono, Y; Hirano, T; Mogi, G

    1998-04-01

    To study the mechanisms of immune responses and immune injuries in inner ears, labyrinthitis was induced by inoculation of keyhole limpet hemocyanin (KLH) into the scala tympani of systemically sensitized guinea pigs. Inner ears were then immunostained for KLH, immunoglobulin G (IgG), albumin, connexin26 (Cx26), and sodium-potassium adenosine triphosphate (Na,K-ATPase). Inflammatory cells containing KLH were observed in the scala tympani and in the collecting venule of the spiral modiolar vein (SMV). Spiral ligament, spiral limbus, and blood vessels including the SMV were diffusely positive for IgG and albumin. Immunoreactivity for Cx26 and Na,K-ATPase was decreased compared with the normal ears in the fibrocytes of the spiral ligament. These results suggest that inflammatory cells and blood constituents could extravasate into the cochlea from blood vessels and that fibrocyte damage in the spiral ligament could cause cochlear dysfunction.

  12. A practical use of a 16-gauge peripheral angiocatheter as an aspiration cautery in endoscopic ear surgery.

    PubMed

    Ozdek, Ali; Keseroglu, Kemal

    2014-08-01

    To define a technique for the practical use of a 16-gauge peripheral venous catheter as an insulated aspiration cautery in endoscopic ear surgery. Retrospective case review. Tertiary referral center. A 16-gauge intravenous catheter was prepared as a cauterization instrument with aspiration. After simple rearrangement of the exterior plastic portion, it was connected to a suction system. With the help of an unipolar cautery, aspiration of the blood and homeostasis was achieved. Hemorrhage of the external ear canal skin after incision can be easily coagulated with this instrument. During follow-up, there were no wound infection, facial nerve paresis, scar formation, and inadvertent burn of the external canal and auricular skin. With the help of this instrument, bleeding control during incision can be easily maintained. It is a simple, easily prepared, and alternative homeostasis technique in endoscopic ear surgery.

  13. The effect of saccular function on static balance ability of profound hearing-impaired children.

    PubMed

    Jafari, Zahra; Asad Malayeri, Saeed

    2011-07-01

    Researches have shown that in clinical practice, balance disorders in children with congenital or early acquired severe to profound hearing loss are probable. The purposes of present study were to specify the percentage of vestibular evoked myogenic potential (VEMP) and an acoustically evoked, short latency negative response (ASNR) recordings and the relation between their presence and static balance ability and postural control of children with profound sensorineural hearing loss (SNHL). Thirty children with profound SNHL, with an average age of 6.93 years, underwent the VEMP and auditory brainstem response (ABR) tests. Both VEMP and ABR were recorded at the threshold level through air-conduction stimulation via an insert receiver. The static balance performance of the hearing-impaired children was tested with six exercises and compared with that of 30 age- and sex-matched normal-hearing children as controls. VEMP was recorded in 53.3% of ears and ASNR in 40.0%. VEMP was revealed in all ears with ASNR, and a significant correlation was shown between their presence (p=0.005) and also between the ASNR wave latency and P1 (p=0.0001) and N1 (p=0.004) wave amplitude of VEMP. There was a significant correlation between the presence of VEMP and ASNR with the performance of the children in two static balance skills, namely standing on one leg with eyes open on a line and the same practice on the balance beam (p≤0.008). There was a close relation between the presence of VEMP and ASNR. Additionally, when ASNR was present, the recording of VEMP could be expected. Successful performance in the static balance exercises with reduced vestibular and somatosensory inputs increased the possibility of the recording of ASNR and VEMP. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  14. Does the Variability of Evoked Tympanic Membrane Displacement Data (V m) Increase as the Magnitude of the Pulse Amplitude Increases?

    PubMed

    Sharif, Sammy J; Campbell-Bell, Cherith M; Bulters, Diederik O; Marchbanks, Robert J; Birch, Anthony A

    2018-01-01

    Evoked tympanic membrane displacement (TMD) measurements, quantified by V m , record small volume changes in the ear canal following stimulation of the acoustic reflex. V m shows a correlation with intracranial pressure (ICP) and has been proposed as an option to non-invasively measure ICP. The spontaneous pulsing of the tympanic membrane, driven by the cardiovascular pulse, may contaminate the recordings and contribute to high measurement variability in some subjects. This study hypothesised that the larger the spontaneous vascular pulse, the larger the variability in V m . Spontaneous and evoked TMD data from each ear in the sitting and supine position were recorded from 100 healthy volunteers using the MMS-14 CCFP analyser. ECG was also recorded to identify each heartbeat. Using bespoke software written in Matlab, spontaneous data were analysed to produce average pulse amplitude (PA) waveforms and evoked data were analysed to calculate average V m and its standard deviation. Averaged spontaneous PA was plotted against V m variability and Pearson's correlation coefficient was calculated to test for a significant linear relationship. There was a strong positive correlation between PA and V m variability in all conditions: left sitting, r = 0.758; left supine, r = 0.665; right sitting, r = 0.755; right supine, r = 0.513. All were significant at p < 0.001. This study shows that large V m variability is associated with a large spontaneous vascular pulse. This suggests that efforts to reduce vascular pulsing from recordings, either by a subtraction technique during post-processing or ECG-gating of the evoking stimulus, may improve reliability of the V m measurement.

  15. 15 CFR Supplement No. 2 to Part 748 - Unique Application and Submission Requirements

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... tools, dimensional inspection machines, direct numerical control systems, specially designed assemblies... Commerce Control List (§ 774.1 of the EAR)—see Category 5 Part 1 Notes 1 and 2 and Part 2 Note 1. License... containing computers to destinations in Country Group D:1 (See Supplement No. 1 to part 740 of the EAR), or...

  16. 15 CFR Supplement No. 2 to Part 748 - Unique Application and Submission Requirements

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... tools, dimensional inspection machines, direct numerical control systems, specially designed assemblies... Commerce Control List (§ 774.1 of the EAR)—see Category 5 Part 1 Notes 1 and 2 and Part 2 Note 1. License... containing computers to destinations in Country Group D:1 (See Supplement No. 1 to part 740 of the EAR), or...

  17. 15 CFR Supplement No. 2 to Part 748 - Unique Application and Submission Requirements

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... tools, dimensional inspection machines, direct numerical control systems, specially designed assemblies... Commerce Control List (§ 774.1 of the EAR)—see Category 5 Part 1 Notes 1 and 2 and Part 2 Note 1. License... containing computers to destinations in Country Group D:1 (See supplement No. 1 to part 740 of the EAR), or...

  18. Comparative Assessment of Torso and Seat Mounted Restraint Systems using Manikins on the Horizontal Impulse Accelerator

    DTIC Science & Technology

    2017-11-01

    rearward rotation of the head towards the back or shoulder blades ). The y- axis of the head runs from right ear canal to the left ear canal with...PERSON (Monitor) a. REPORT Unclassified b. ABSTRACT Unclassified c . THIS PAGE Unclassified Chris Burneka 19b. TELEPHONE NUMBER...92 APPENDIX C . SAMPLE DATA SHEETS

  19. Exceeding Parents' Expectations in Ear-Nose-Throat Outpatient Facilities: The Development and Analysis of a Questionnaire

    ERIC Educational Resources Information Center

    Margaritis, Eleftherios; Katharaki, Maria; Katharakis, George

    2012-01-01

    The study attempts to develop an outpatient service quality scale by investigating the key dimensions which assess parental satisfaction and provides a recommendation on an improved health service delivery system. The survey was conducted in an Ear-Nose-Throat outpatient clinic of a Greek public pediatric hospital. A total of 127 parents in…

  20. Application of the remote microphone method to active noise control in a mobile phone.

    PubMed

    Cheer, Jordan; Elliott, Stephen J; Oh, Eunmi; Jeong, Jonghoon

    2018-04-01

    Mobile phones are used in a variety of situations where environmental noise may interfere with the ability of the near-end user to communicate with the far-end user. To overcome this problem, it might be possible to use active noise control technology to reduce the noise experienced by the near-end user. This paper initially demonstrates that when an active noise control system is used in a practical mobile phone configuration to minimise the noise measured by an error microphone mounted on the mobile phone, the attenuation achieved at the user's ear depends strongly on the position of the source generating the acoustic interference. To help overcome this problem, a remote microphone processing strategy is investigated that estimates the pressure at the user's ear from the pressure measured by the microphone on the mobile phone. Through an experimental implementation, it is demonstrated that this arrangement achieves a significant improvement in the attenuation measured at the ear of the user, compared to the standard active control strategy. The robustness of the active control system to changes in both the interfering sound field and the position of the mobile device relative to the ear of the user is also investigated experimentally.

  1. A Fully-Implantable Cochlear Implant SoC with Piezoelectric Middle-Ear Sensor and Arbitrary Waveform Neural Stimulation.

    PubMed

    Yip, Marcus; Jin, Rui; Nakajima, Hideko Heidi; Stankovic, Konstantina M; Chandrakasan, Anantha P

    2015-01-01

    A system-on-chip for an invisible, fully-implantable cochlear implant is presented. Implantable acoustic sensing is achieved by interfacing the SoC to a piezoelectric sensor that detects the sound-induced motion of the middle ear. Measurements from human cadaveric ears demonstrate that the sensor can detect sounds between 40 and 90 dB SPL over the speech bandwidth. A highly-reconfigurable digital sound processor enables system power scalability by reconfiguring the number of channels, and provides programmable features to enable a patient-specific fit. A mixed-signal arbitrary waveform neural stimulator enables energy-optimal stimulation pulses to be delivered to the auditory nerve. The energy-optimal waveform is validated with in-vivo measurements from four human subjects which show a 15% to 35% energy saving over the conventional rectangular waveform. Prototyped in a 0.18 μ m high-voltage CMOS technology, the SoC in 8-channel mode consumes 572 μ W of power including stimulation. The SoC integrates implantable acoustic sensing, sound processing, and neural stimulation on one chip to minimize the implant size, and proof-of-concept is demonstrated with measurements from a human cadaver ear.

  2. Ear-Canal Reflectance, Umbo Velocity and Tympanometry in Normal Hearing Adults

    PubMed Central

    Rosowski, John J; Nakajima, Hideko H.; Hamade, Mohamad A.; Mafoud, Lorice; Merchant, Gabrielle R.; Halpin, Christopher F.; Merchant, Saumil N.

    2011-01-01

    Objective This study compares measurements of ear-canal reflectance (ECR) to other objective measurements of middle-ear function including, audiometry, umbo velocity (VU), and tympanometry in a population of strictly defined normal hearing ears. Design Data were prospectively gathered from 58 ears of 29 normal hearing subjects, 16 female and 13 male, aged 22–64 years. Subjects met all of the following criteria to be considered as having normal hearing. (1) No history of significant middle-ear disease. (2) No history of otologic surgery. (3) Normal tympanic membrane (TM) on otoscopy. (4) Pure-tone audiometric thresholds of 20 dB HL or better for 0.25 – 8 kHz. (5) Air-bone gaps no greater than 15 dB at 0.25 kHz and 10 dB for 0.5 – 4 kHz. (6) Normal, type-A peaked tympanograms. (7) All subjects had two “normal” ears (as defined by these criteria). Measurements included pure-tone audiometry for 0.25 – 8 kHz, standard 226 Hz tympanometry, Ear canal reflectance(ECR) for 0.2 – 6 kHz at 60 dB SPL using the Mimosa Acoustics HearID system, and Umbo Velocity (VU ) for 0.3 – 6 kHz at 70–90 dB SPL using the HLV-1000 laser Doppler vibrometer (Polytec Inc). Results Mean power reflectance (|ECR|2) was near 1.0 at 0.2– 0.3 kHz, decreased to a broad minimum of 0.3 to 0.4 between 1 and 4 kHz, and then sharply increased to almost 0.8 by 6 kHz. The mean pressure reflectance phase angle (∠ECR) plotted on a linear frequency scale showed a group delay of approximately 0.1 ms for 0.2 – 6 kHz. Small significant differences were observed in |ECR|2 at the lowest frequencies between right and left ears, and between males and females at 4 kHz. |ECR|2 decreased with age, but reached significance only at 1 kHz. Our ECR measurements were generally similar to previous published reports. Highly significant negative correlations were found between |ECR|2 and VU for frequencies below 1 kHz. Significant correlations were also found between the tympanometrically determined peak total compliance and |ECR|2 and The results suggest that middle-ear compliance VU at frequencies below 1 kHz. contributes significantly to the measured power reflectance and umbo velocity at frequencies below 1 kHz, but not at higher frequencies. Conclusions This study has established a database of objective measurements of middle ear function (ear-canal reflectance, umbo velocity, tympanometry) in a population of strictly defined normal hearing ears. The data will promote our understanding of normal middle ear function, and will serve as a control for comparison to similar measurements made in pathological ears. PMID:21857517

  3. Physiological correlates of sound localization in a parasitoid fly, Ormia ochracea

    NASA Astrophysics Data System (ADS)

    Oshinsky, Michael Lee

    A major focus of research in the nervous system is the investigation of neural circuits. The question of how neurons connect to form functional units has driven modern neuroscience research from its inception. From the beginning, the neural circuits of the auditory system and specifically sound localization were used as a model system for investigating neural connectivity and computation. Sound localization lends itself to this task because there is no mapping of spatial information on a receptor sheet as in vision. With only one eye, an animal would still have positional information for objects. Since the receptor sheet in the ear is frequency oriented and not spatially oriented, positional information for a sound source does not exist with only one ear. The nervous system computes the location of a sound source based on differences in the physiology of the two ears. In this study, I investigated the neural circuits for sound localization in a fly, Ormia ochracea (Diptera, Tachinidae, Ormiini), which is a parasitoid of crickets. This fly possess a unique mechanically coupled hearing organ. The two ears are contained in one air sac and a cuticular bridge, that has a flexible spring-like structure at its center, connects them. This mechanical coupling preprocesses the sound before it is detected by the nervous system and provides the fly with directional information. The subject of this study is the neural coding of the location of sound stimuli by a mechanically coupled auditory system. In chapter 1, I present the natural history of an acoustic parasitoid and I review the peripheral processing of sound by the Ormian ear. In chapter 2, I describe the anatomy and physiology of the auditory afferents. I present this physiology in the context of sound localization. In chapter 3, I describe the directional dependent physiology for the thoracic local and ascending acoustic interneurons. In chapter 4, I quantify the threshold and I detail the kinematics of the phonotactic walking behavior in Ormia ochracea. I also quantify the angular resolution of the phonotactic turning behavior. Using a model, I show that the temporal coding properties of the afferents provide most of the information required by the fly to localize a singing cricket.

  4. Near-bottom hydrophone measurements of ambient noise and sperm whale vocalizations in the northern Gulf of Mexico

    NASA Astrophysics Data System (ADS)

    Newcomb, Joal; Fisher, Robert; Field, Robert; Turgut, Altan; Ioup, George; Ioup, Juliette; Rayborn, Grayson; Kuczaj, Stan; Caruthers, Jerald; Goodman, Ralph; Sidorovskaia, Natalia

    2002-05-01

    Three bottom-moored hydrophones, 50 m above the bottom, were placed on a downslope line, ending at the largest concentration of sperm whale sightings in the northern Gulf of Mexico, in 600 m, 800 m, and 1000 m water depths. These depths were chosen after upslope propagation modeling, using historical databases, showed transmission losses greater than 110 dB at hydrophones near the bottom in water shallower than 600 m for a 500 m deep source at the 1000 m contour. These autonomously recording hydrophones were environmental acoustic recording system (EARS) buoys obtained from the Naval Oceanographic Office. They were capable of recording signals up to 5500 Hz continuously for 36 days and were deployed from July 17 through August 21. During this period a major marine mammal exercise was being conducted at the surface by the Minerals Management Service and the National Marine Fisheries Service, with other government and university scientists, in which temporary acoustic recording devices were attached to the whales and the whales were monitored by a surface towed array. Our near-bottom measurements of ambient noise and sperm whale vocalizations are discussed and compared to those surface and on-whale measurements. [Research supported by ONR.

  5. Some Remarks on Imaging of the Inner Ear: Options and Limitations.

    PubMed

    Giesemann, A; Hofmann, E

    2015-10-01

    The temporal bone has a highly complex anatomical structure, in which the sensory organs of the cochlea and the vestibular system are contained within a small space together with the sound-conducting system of the middle ear. Detailed imaging is thus required in this anatomical area. There are a great many clinical aims for which the highest-possible spatial resolution is required. These include the localization of cerebrospinal fluid fistulas, the detection of malformations of the middle and inner ear and the vestibulocochlear nerve, an aberrant course of the facial nerve and anomalies of the arterial and venous structures, the confirmation of dehiscence of the semicircular canals and finally, the verification of endolymphatic hydrops in cases of Ménière's disease. However, the term 'high resolution' is very time dependent. Two milestones in this respect have been (in 1991) the 3D visualization of the inner ear by means of maximum-intensity projection (MIP) of a T2-weighted constructive interference in steady state (CISS) sequence of a 1.5-tesla magnetic resonance imaging (MRI) scanner (Tanioka et al., Radiology 178:141-144, 1991) and (in 1997) imaging of the vestibulocochlear nerve for the diagnosis of hypoplasia inside the internal auditory canal using the same sequence (Casselman et al., Radiology 202:773-781, 1997).The objective of this article is to highlight the options for, and the challenges of, contemporary imaging with regard to some clinical issues relating to the inner ear.

  6. Assessment of skills using a virtual reality temporal bone surgery simulator.

    PubMed

    Linke, R; Leichtle, A; Sheikh, F; Schmidt, C; Frenzel, H; Graefe, H; Wollenberg, B; Meyer, J E

    2013-08-01

    Surgery on the temporal bone is technically challenging due to its complex anatomy. Precise anatomical dissection of the human temporal bone is essential and is fundamental for middle ear surgery. We assessed the possible application of a virtual reality temporal bone surgery simulator to the education of ear surgeons. Seventeen ENT physicians with different levels of surgical training and 20 medical students performed an antrotomy with a computer-based virtual temporal bone surgery simulator. The ease, accuracy and timing of the simulated temporal bone surgery were assessed using the automatic assessment software provided by the simulator device and additionally with a modified Final Product Analysis Scale. Trained ENT surgeons, physicians without temporal bone surgical training and medical students were all able to perform the antrotomy. However, the highly trained ENT surgeons were able to complete the surgery in approximately half the time, with better handling and accuracy as assessed by the significant reduction in injury to important middle ear structures. Trained ENT surgeons achieved significantly higher scores using both dissection analysis methods. Surprisingly, there were no significant differences in the results between medical students and physicians without experience in ear surgery. The virtual temporal bone training system can stratify users of known levels of experience. This system can be used not only to improve the surgical skills of trained ENT surgeons for more successful and injury-free surgeries, but also to train inexperienced physicians/medical students in developing their surgical skills for the ear.

  7. Eocene evolution of whale hearing.

    PubMed

    Nummela, Sirpa; Thewissen, J G M; Bajpai, Sunil; Hussain, S Taseer; Kumar, Kishor

    2004-08-12

    The origin of whales (order Cetacea) is one of the best-documented examples of macroevolutionary change in vertebrates. As the earliest whales became obligately marine, all of their organ systems adapted to the new environment. The fossil record indicates that this evolutionary transition took less than 15 million years, and that different organ systems followed different evolutionary trajectories. Here we document the evolutionary changes that took place in the sound transmission mechanism of the outer and middle ear in early whales. Sound transmission mechanisms change early on in whale evolution and pass through a stage (in pakicetids) in which hearing in both air and water is unsophisticated. This intermediate stage is soon abandoned and is replaced (in remingtonocetids and protocetids) by a sound transmission mechanism similar to that in modern toothed whales. The mechanism of these fossil whales lacks sophistication, and still retains some of the key elements that land mammals use to hear airborne sound.

  8. Scala vestibuli pressure and three-dimensional stapes velocity measured in direct succession in gerbil.

    PubMed

    Decraemer, W F; de La Rochefoucauld, O; Dong, W; Khanna, S M; Dirckx, J J J; Olson, E S

    2007-05-01

    It was shown that the mode of vibration of the stapes has a predominant piston component but rotations producing tilt of the footplate are also present. Tilt and piston components vary with frequency. Separately it was shown that the pressure gain between ear canal and scala vestibuli was a remarkably flat and smooth function of frequency. Is tilt functional contributing to the pressure in the scala vestibuli and helping in smoothing the pressure gain? In experiments on gerbil the pressure in the scala vestibuli directly behind the footplate was measured while recording simultaneously the pressure produced by the sound source in the ear canal. Successively the three-dimensional motion of the stapes was measured in the same animal. Combining the vibration measurements with an anatomical shape measurement from a micro-CT (CT: computed tomography) scan the piston-like motion and the tilt of the footplate was calculated and correlated to the corresponding scala vestibuli pressure curves. No evidence was found for the hypothesis that dips in the piston velocity are filled by peaks in tilt in a systematic way to produce a smooth middle ear pressure gain function. The present data allowed calculations of the individual cochlear input impedances.

  9. [Value of condensation and rarefaction click evoked action potential latency difference in the diagnosis of Meniere's disease].

    PubMed

    Wang, Z; Shao, X; Yan, W; Lin, H

    2000-06-01

    To study the value of condensation and rarefaction clicks evoked action potential (AP) latency difference (LD) in diagnosis of Meniere's disease. AP was recorded with ECochG in controls (50 ears) and patients with Meniere's disease(90 ears) and sensorineural hearing loss(SNHL) of other origins(60 ears). LD was calculated and analyzed. LD in patients with Meniere's disease was (0.30 +/- 0.15) ms, which was significantly larger than that of controls(0.18 +/- 0.07) ms and of patients with SNHL of other origins(0.20 +/- 0.10) ms (P < 0.01). In the group of Meniere's disease, LD in patients with the mild and moderate hearing impairment was larger than those with severe hearing loss(P < 0.01) and LD in patients with low tone or high tone auditory sensation curve was larger than those with flat auditory sensation curve(P < 0.01). Positive rate was 4/60(6.7%) in other SNHL patients and 58/90(64.0%) in Meniere's disease group respectively. The increase in condensation and rarefaction click evoked AP latency difference can be an objective parameter in diagnosis of Meniere's disease.

  10. Evaluation of the antioedematogenic, free radical scavenging and antimicrobial activities of aerial parts of Tillandsiastreptocarpa Baker-Bromeliaceae.

    PubMed

    Delaporte, R H; Sarragiotto, M H; Takemura, O S; Sánchez, G M; Filho, B P D; Nakamura, C V

    2004-12-01

    The crude methanolic extract of the aerial parts of Tillandsiastreptocarpa was investigated for their acute toxicity and antioedematogenic, antioxidant and antimicrobial activities. Also, the antioedematogenic activity of the hexane fraction resulting from the partition of the crude methanolic extract was evaluated. The methanolic extract and the hexane fraction showed significant (P < 0.05) inhibition of ear oedema, observed at 2 mg/ear in the croton oil-induced mice ear oedema test. In the 2,2-diphenyl-1-picrylhydrazyl (DPPH) free radical scavenging test, a high reactivity and potent antioxidant effect (IC(50) = 0.0056%, w/v) were observed for the methanolic extract. The antimicrobial activity assay showed that the crude methanolic extract was inactive toward Escherichiacoli, Staphylococcusaureus, Pseudomonasaeruginosa, Bacillussubtilis, Candidaalbicans, C. parapsilosis, C. krusei and C. tropicalis (MIC > 500 microg/ml). The methanolic extract showed no toxic effect on mice at a single dose of 2000 mg/kg (p.o). Common side effects including mild diarrhoea, loss of weight and depression were not recorded. The compounds cycloartenol, 4',5-dihydroxy-3',7-dimethoxyflavanone and a mixture of the steroids stigmasterol, beta-sitosterol and campesterol, were isolated from the hexane fraction and identified by spectroscopic methods.

  11. Relationship Between Audio-Vestibular Functional Tests and Inner Ear MRI in Meniere's Disease.

    PubMed

    Quatre, Raphaële; Attyé, Arnaud; Karkas, Alexandre; Job, Agnès; Dumas, Georges; Schmerber, Sébastien

    2018-04-25

    Meniere's disease is an inner ear disorder generally attributed to an endolymphatic hydrops. Different electrophysiological tests and imaging techniques have been developed to improve endolymphatic hydrops diagnosis. The goal of our study was to compare the sensitivity and the specificity of delayed inner ear magnetic resonance imaging (MRI) after intravenous injection of gadolinium with extratympanic clicks electrocochleography (EcochG), phase shift of distortion product otoacoustic emissions (shift-DPOAEs), and cervical vestibular-evoked myogenic potentials (cVEMP) for the diagnosis of Meniere's disease. Forty-one patients, with a total of 50 affected ears, were included prospectively from April 2015 to April 2016 in our institution. Patients included had definite or possible Meniere's disease based on the latest American Academy of Otolaryngology-Head and Neck Surgery guidelines revised in 2015. All patients went through delayed inner ear MRI after intravenous injection of gadolinium (three dimension-fluid attenuated inversion recovery sequences), pure-tone audiometry, extratympanic clicks EcochG, shift-DPOAEs, and cVEMP on the same day. Endolymphatic hydrops was graded on MRI using the saccule to utricle ratio inversion defined as when the saccule appeared equal or larger than the utricle. Abnormal EcochG and shift-DPOAEs in patients with definite Meniere's disease (DMD) were found in 68 and 64.5%, respectively. The two methods were significantly associated in DMD group. In DMD group, 25.7% had a positive MRI. The correlation between MRI versus EcochG and MRI versus shift-DPOAEs was not significant. MRI hydrops detection was correlated with hearing loss. Finally, 22.9% of DMD group had positive cVEMP. EcochG and shift-DPOAEs were both well correlated with clinical criteria of Meniere's disease. Inner ear MRI showed hydrops when hearing loss was higher than 35 dB. The shift-DPOAEs presented the advantage of a rapid and easy measurement if DPOAEs could be recorded (i.e., hearing threshold <60dB). In contrast, EcochG can be performed regardless of hearing loss. In combination with shift-DPOAEs, it enhances the chances to confirm the diagnosis with a better confidence.

  12. The Effects of Acoustic Bandwidth on Simulated Bimodal Benefit in Children and Adults with Normal Hearing.

    PubMed

    Sheffield, Sterling W; Simha, Michelle; Jahn, Kelly N; Gifford, René H

    2016-01-01

    The primary purpose of this study was to examine the effect of acoustic bandwidth on bimodal benefit for speech recognition in normal-hearing children with a cochlear implant (CI) simulation in one ear and low-pass filtered stimuli in the contralateral ear. The effect of acoustic bandwidth on bimodal benefit in children was compared with the pattern of adults with normal hearing. Our hypothesis was that children would require a wider acoustic bandwidth than adults to (1) derive bimodal benefit, and (2) obtain asymptotic bimodal benefit. Nineteen children (6 to 12 years) and 10 adults with normal hearing participated in the study. Speech recognition was assessed via recorded sentences presented in a 20-talker babble. The AzBio female-talker sentences were used for the adults and the pediatric AzBio sentences (BabyBio) were used for the children. A CI simulation was presented to the right ear and low-pass filtered stimuli were presented to the left ear with the following cutoff frequencies: 250, 500, 750, 1000, and 1500 Hz. The primary findings were (1) adults achieved higher performance than children when presented with only low-pass filtered acoustic stimuli, (2) adults and children performed similarly in all the simulated CI and bimodal conditions, (3) children gained significant bimodal benefit with the addition of low-pass filtered speech at 250 Hz, and (4) unlike previous studies completed with adult bimodal patients, adults and children with normal hearing gained additional significant bimodal benefit with cutoff frequencies up to 1500 Hz with most of the additional benefit gained with energy below 750 Hz. Acoustic bandwidth effects on simulated bimodal benefit were similar in children and adults with normal hearing. Should the current results generalize to children with CIs, these results suggest pediatric CI recipients may derive significant benefit from minimal acoustic hearing (<250 Hz) in the nonimplanted ear and increasing benefit with broader bandwidth. Knowledge of the effect of acoustic bandwidth on bimodal benefit in children may help direct clinical decisions regarding a second CI, continued bimodal hearing, and even optimizing acoustic amplification for the nonimplanted ear.

  13. Ethnopharmacological study and topical anti-inflammatory activity of crude extract from Poikilacanthus glandulosus (Nees) Ariza leaves.

    PubMed

    de Brum, Thiele Faccim; Camponogara, Camila; da Silva Jesus, Roberta; Belke, Bianca Vargas; Piana, Mariana; Boligon, Aline Augusti; Pires, Fernanda Brum; Oliveira, Sara Marchesan; da Rosa, Marcelo Barcellos; de Freitas Bauermann, Liliane

    2016-12-04

    Ethnopharmacological studies are important tools as records and documentation of the empirical uses of medicinal plants in traditional communities with the purpose of generating useful knowledge to lead to the development of new medicines, biodiversity conservation and enhancement of knowledge and local culture. Poikilacanthus glandulosus is widely used by the population of City of Santiago, in Brazil, nevertheless, it does not have any validation regarding its use and its medicinal effects. The objective of this study was to perform one ethnopharmacological survey about P. glandulosus in the City of Santiago and determine the anti-inflammatory activity in order to prove its uses in popular medicine. Personal and ethnopharmacological data were collected through a prepared questionnaire. The phytochemical analysis was performed observing the individual methodology for each reaction and by HPLC-UV. The antiedematogenic and anti-inflammatory (cell infiltration and histological procedure) activities of the P. glandulosus (0.01-1000μg/ear) were evaluated in the ear edema model induced by topical application of croton oil. P. glandulosus is known in City of Santiago as "Gaiana" and its macerated leaves and branches are prepared with alcohol or sugarcane liquor especially for insect bites, cicatrization and inflammation. HPLC analysis revealed the presence of maslinic acid (2.024±0.10mg/g), uvaol (0.124±0.02mg/g) and sitosterol (0.502±0.05mg/g). The topical application of crude extract of P. glandulosus reduced in a dose-dependent manner the croton oil-induced ear edema and myeloperoxidase activity (neutrophils infiltration marker) with maximum inhibition of 87±2% and 64±12%, respectively at 1000µg/ear. Dexamethasone (100µg/ear), used as a positive control, inhibited croton oil-induced ear edema in 89±3% and decreased myeloperoxidase activity in 50±3%. Both P. glandulosus as dexamethasone reduced cell infiltration when evaluated by histological procedure CONCLUSION: This work allowed us to understand the specie P. glandulosus through ethnopharmacological study and it showed that the crude extract presented antiedematogenic and anti-inflammatory actions, proving their traditional use as anti-inflammatory. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  14. A comparison of the brainstem auditory evoked response in healthy ears of unilaterally deaf dogs and bilaterally hearing dogs.

    PubMed

    Plonek, M; Nicpoń, J; Kubiak, K; Wrzosek, M

    2017-03-01

    Auditory plasticity in response to unilateral deafness has been reported in various animal species. Subcortical changes occurring in unilaterally deaf young dogs using the brainstem auditory evoked response have not been evaluated yet. The aim of this study was to assess the brainstem auditory evoked response findings in dogs with unilateral hearing loss, and compare them with recordings obtained from healthy dogs. Brainstem auditory evoked responses (amplitudes and latencies of waves I, II, III, V, the V/I wave amplitude ratio, wave I-V, I-III and III-V interpeak intervals) were studied retrospectively in forty-six privately owned dogs, which were either unilaterally deaf or had bilateral hearing. The data obtained from the hearing ears in unilaterally deaf dogs were compared to values obtained from their healthy littermates. Statistically significant differences in the amplitude of wave III and the V/I wave amplitude ratio at 75 dB nHL were found between the group of unilaterally deaf puppies and the control group. The recordings of dogs with single-sided deafness were compared, and the results showed no statistically significant differences in the latencies and amplitudes of the waves between left- (AL) and right-sided (AR) deafness. The recordings of the brainstem auditory evoked response in canines with unilateral inborn deafness in this study varied compared to recordings from healthy dogs. Future studies looking into electrophysiological assessment of hearing in conjunction with imaging modalities to determine subcortical auditory plasticity and auditory lateralization in unilaterally deaf dogs are warranted.

  15. 3D finite element model of the chinchilla ear for characterizing middle ear functions

    PubMed Central

    Wang, Xuelin; Gan, Rong Z.

    2016-01-01

    Chinchilla is a commonly used animal model for research of sound transmission through the ear. Experimental measurements of the middle ear transfer function in chinchillas have shown that the middle ear cavity greatly affects the tympanic membrane (TM) and stapes footplate (FP) displacements. However, there is no finite element (FE) model of the chinchilla ear available in the literature to characterize the middle ear functions with the anatomical features of the chinchilla ear. This paper reports a recently completed 3D FE model of the chinchilla ear based on X-ray micro-computed tomography images of a chinchilla bulla. The model consisted of the ear canal, TM, middle ear ossicles and suspensory ligaments, and the middle ear cavity. Two boundary conditions of the middle ear cavity wall were simulated in the model as the rigid structure and the partially flexible surface, and the acoustic-mechanical coupled analysis was conducted with these two conditions to characterize the middle ear function. The model results were compared with experimental measurements reported in the literature including the TM and FP displacements and the middle ear input admittance in chinchilla ear. An application of this model was presented to identify the acoustic role of the middle ear septa - a unique feature of chinchilla middle ear cavity. This study provides the first 3D FE model of the chinchilla ear for characterizing the middle ear functions through the acoustic-mechanical coupled FE analysis. PMID:26785845

  16. Effect of neonatal asphyxia on the impairment of the auditory pathway by recording auditory brainstem responses in newborn piglets: a new experimentation model to study the perinatal hypoxic-ischemic damage on the auditory system.

    PubMed

    Alvarez, Francisco Jose; Revuelta, Miren; Santaolalla, Francisco; Alvarez, Antonia; Lafuente, Hector; Arteaga, Olatz; Alonso-Alconada, Daniel; Sanchez-del-Rey, Ana; Hilario, Enrique; Martinez-Ibargüen, Agustin

    2015-01-01

    Hypoxia-ischemia (HI) is a major perinatal problem that results in severe damage to the brain impairing the normal development of the auditory system. The purpose of the present study is to study the effect of perinatal asphyxia on the auditory pathway by recording auditory brain responses in a novel animal experimentation model in newborn piglets. Hypoxia-ischemia was induced to 1.3 day-old piglets by clamping 30 minutes both carotid arteries by vascular occluders and lowering the fraction of inspired oxygen. We compared the Auditory Brain Responses (ABRs) of newborn piglets exposed to acute hypoxia/ischemia (n = 6) and a control group with no such exposure (n = 10). ABRs were recorded for both ears before the start of the experiment (baseline), after 30 minutes of HI injury, and every 30 minutes during 6 h after the HI injury. Auditory brain responses were altered during the hypoxic-ischemic insult but recovered 30-60 minutes later. Hypoxia/ischemia seemed to induce auditory functional damage by increasing I-V latencies and decreasing wave I, III and V amplitudes, although differences were not significant. The described experimental model of hypoxia-ischemia in newborn piglets may be useful for studying the effect of perinatal asphyxia on the impairment of the auditory pathway.

  17. Audit of 117 otoplasties for prominent ear by one surgeon using a cartilage-cutting procedure.

    PubMed

    Brian, Tess; Cheng, Paul T; Loo, Stanley S

    2018-02-07

    The plethora of surgical procedures for prominent ear correction reflects lack of satisfaction with outcomes achieved. This paper describes a cartilage-cutting otoplasty procedure and reports an audit of its outcomes. Discharge coding was used to retrospectively identify patients who had undergone the otoplasty of interest at Middlemore Hospital, Auckland, during the 5 years from March 2010 to the end of February 2015. Hospital records were accessed. Demographic, procedure and patient satisfaction data were recorded and analysed (PASW/SPSS Statistics 18.0). Chi-square test and t-test were used to assess associations, with significance accepted at two-sided P < 0.05. Sixty-four patients underwent the specified otoplasty (54.7% females: mean age 9.5 years (standard deviation, SD: 4.2; range: 4-20)), of whom 93.8% had bilateral procedures with mean surgical time of 61 min (SD: 14; range: 34-94). This was significantly shorter (P < 0.001) than for bilateral surgeries by all other techniques and surgeons in the review period. None of the 117 procedures of interest subsequently had suture extrusion or revision surgery. Mean time from surgery to satisfaction determination was 993 days (SD: 521; range: 111-1850) for 43 (67.2%) patients. 23.3% believed that there had been aesthetically insignificant partial recurrence of prominence, typically of one ear only. This was insufficient for all but one patient to consider repeat otoplasty. Surgery outcome was rated 'very satisfactory' and 'satisfactory' by 90.7% and 9.3% of patients/parents, respectively. All would recommend the surgery to others. With infrequent complications and recurrence requiring revision, and without long-term reliance on sutures, the otoplasty reported is time-efficient, safe and generates high patient satisfaction. © 2018 Royal Australasian College of Surgeons.

  18. The Clinical Utility of Vestibular Evoked Myogenic Potentials in Patients of Benign Paroxysmal Positional Vertigo.

    PubMed

    Sreenivasan, Anuprasad; Sivaraman, Ganesan; Parida, Pradiptata Kumar; Alexander, Arun; Saxena, Sunil Kumar; Suria, Gopalakrishnan

    2015-06-01

    Vestibular Evoked Myogenic Potentials (VEMP) is an emerging tool to diagnose Benign Paroxysmal Positional Vertigo (BPPV). The clinical utility of VEMP has been reported only in small accord in Indian literature. To study the latency and amplitude of VEMP in patients with BPPV and compare it with that of normal subjects. The study included two groups. Group one (control group) were 18 normal subjects. Group two (test group) were 15 subjects with unilateral BPPV. Those subjects who fulfilled the selection criteria based on case history and audiological assessment were taken for the VEMP recording. The VEMP response consist of positive and negative successive waves (pI-nI), with latency values in adults about 13 and 23 milliseconds respectively. Data was analysed using Statistical Package for Social Sciences (SPSS) version 12 (Chicago, IL, USA). Unpaired t-test was employed to measure the statistical difference between control group and test group. The difference in n23 and the peak to peak amplitude between the ipsilateral and contralateral ears of the test group were statistically significant, whereas such a difference in the p13 latency turned out to be statistically insignificant. It should be noted that, out of 15 patients in the test group, five patients showed only artifact tracer recordings in both the ears which is considered as no response. The heterogeneity of the results extended from absence of VEMP to prolongation of both p13, n23; prolongation of p13 alone; and even side to side variations. Absent response from the ipsilateral ear, prolonged latency of n23 and decreased peak to peak amplitude (p13, n23), indicates the disease pathology. However, large sample size is required to draw further conclusions and to consolidate the usage of VEMP in the diagnosis of BPPV.

  19. Auditory brainstem evoked responses and temperature monitoring during pediatric cardiopulmonary bypass.

    PubMed

    Rodriguez, R A; Edmonds, H L; Auden, S M; Austin, E H

    1999-09-01

    To examine the effects of temperature on auditory brainstem responses (ABRs) in infants during hypothermic cardiopulmonary bypass for total circulatory arrest (TCA). The relationship between ABRs (as a surrogate measure of core-brain temperature) and body temperature as measured at several temperature monitoring sites was determined. In a prospective, observational study, ABRs were recorded non-invasively at normothermia and at every 1 or 2 degrees C change in ear-canal temperature during cooling and rewarming in 15 infants (ages: 2 days to 14 months) that required TCA. The ABR latencies and amplitudes and the lowest temperatures at which an ABR was identified (the threshold) were measured during both cooling and rewarming. Temperatures from four standard temperature monitoring sites were simultaneously recorded. The latencies of ABRs increased and amplitudes decreased with cooling (P < 0.01), but rewarming reversed these effects. The ABR threshold temperature as related to each monitoring site (ear-canal, nasopharynx, esophagus and bladder) was respectively determined as 23 +/- 2.2 degrees C, 20.8 +/- 1.7 degrees C, 14.6 +/- 3.4 degrees C, and 21.5 +/- 3.8 degrees C during cooling and 21.8 +/- 1.6 degrees C, 22.4 +/- 2.0 degrees C, 27.6 +/- 3.6 degrees C, and 23.0 +/- 2.4 degrees C during rewarming. The rewarming latencies were shorter and Q10 latencies smaller than the corresponding cooling values (P < 0.01). Esophageal and bladder sites were more susceptible to temperature variations as compared with the ear-canal and nasopharynx. No temperature site reliably predicted an electrophysiological threshold. A faster latency recovery during rewarming suggests that body temperature monitoring underestimates the effects of rewarming in the core-brain. ABRs may be helpful to monitor the effects of cooling and rewarming on the core-brain during pediatric cardiopulmonary bypass.

  20. Shapes of Differential Pulse Voltammograms and Level of Metallothionein at Different Animal Species.

    PubMed

    Adam, Vojtech; Beklova, Miroslava; Pikula, Jiri; Hubalek, Jaromir; Trnkova, Libuse; Kizek, Rene

    2007-10-19

    Metallothioneins play a key role in maintaining homeostasis of essential metalsand in protecting of cells against metal toxicity as well as oxidative damaging. Exceptinghumans, blood levels of metallothionein have not yet been reported from any animalspecies. Blood plasma samples of 9 animal species were analysed by the adsorptive transferstripping technique to obtain species specific voltammograms. Quite distinct records wereobtained from the Takin (Budorcas taxicolor), while other interesting records were observedin samples from the European Bison (Bison bonasus bonasus) and the Red-eared Slider(Trachemys scripta elegans). To quantify metallothionein the catalytic peak Cat2 was used,well developed in the Domestic Fowl (Gallus gallus f. domestica) and showing a very lowsignal in the Red Deer (Cervus elaphus). The highest levels of metallothionein reachingover 20 μM were found in the Domestic Fowl. High levels of MT were also found in theBearded Dragon (Pogona vitticeps) and the Grey Wolf (Canis lupus lupus). The lowestvalues of about 1-3 μM were determined in the Red-eared Slider, Takin and Red Deer. Employing a simple electrochemical detection it was possible to examine variation in blood metallothionein in different species of vertebrates.

  1. Shapes of Differential Pulse Voltammograms and Level of Metallothionein at Different Animal Species

    PubMed Central

    Adam, Vojtech; Beklova, Miroslava; Pikula, Jiri; Hubalek, Jaromir; Trnkova, Libuse; Kizek, Rene

    2007-01-01

    Metallothioneins play a key role in maintaining homeostasis of essential metals and in protecting of cells against metal toxicity as well as oxidative damaging. Excepting humans, blood levels of metallothionein have not yet been reported from any animal species. Blood plasma samples of 9 animal species were analysed by the adsorptive transfer stripping technique to obtain species specific voltammograms. Quite distinct records were obtained from the Takin (Budorcas taxicolor), while other interesting records were observed in samples from the European Bison (Bison bonasus bonasus) and the Red-eared Slider (Trachemys scripta elegans). To quantify metallothionein the catalytic peak Cat2 was used, well developed in the Domestic Fowl (Gallus gallus f. domestica) and showing a very low signal in the Red Deer (Cervus elaphus). The highest levels of metallothionein reaching over 20 µM were found in the Domestic Fowl. High levels of MT were also found in the Bearded Dragon (Pogona vitticeps) and the Grey Wolf (Canis lupus lupus). The lowest values of about 1-3 µM were determined in the Red-eared Slider, Takin and Red Deer. Employing a simple electrochemical detection it was possible to examine variation in blood metallothionein in different species of vertebrates. PMID:28903235

  2. Loss of CD28 on Peripheral T Cells Decreases the Risk for Early Acute Rejection after Kidney Transplantation

    PubMed Central

    Dedeoglu, Burç; Meijers, Ruud W. J.; Klepper, Mariska; Hesselink, Dennis A.; Baan, Carla C.; Litjens, Nicolle H. R.; Betjes, Michiel G. H.

    2016-01-01

    Background End-stage renal disease patients have a dysfunctional, prematurely aged peripheral T-cell system. Here we hypothesized that the degree of premature T-cell ageing before kidney transplantation predicts the risk for early acute allograft rejection (EAR). Methods 222 living donor kidney transplant recipients were prospectively analyzed. EAR was defined as biopsy proven acute allograft rejection within 3 months after kidney transplantation. The differentiation status of circulating T cells, the relative telomere length and the number of CD31+ naive T cells were determined as T-cell ageing parameters. Results Of the 222 patients analyzed, 30 (14%) developed an EAR. The donor age and the historical panel reactive antibody score were significantly higher (p = 0.024 and p = 0.039 respectively) and the number of related donor kidney transplantation was significantly lower (p = 0.018) in the EAR group. EAR-patients showed lower CD4+CD28null T-cell numbers (p<0.01) and the same trend was observed for CD8+CD28null T-cell numbers (p = 0.08). No differences regarding the other ageing parameters were found. A multivariate Cox regression analysis showed that higher CD4+CD28null T-cell numbers was associated with a lower risk for EAR (HR: 0.65, p = 0.028). In vitro, a significant lower percentage of alloreactive T cells was observed within CD28null T cells (p<0.001). Conclusion Immunological ageing-related expansion of highly differentiated CD28null T cells is associated with a lower risk for EAR. PMID:26950734

  3. Toxicology study for magnetic injection of prednisolone into the rat cochlea.

    PubMed

    Shimoji, M; Ramaswamy, B; Shukoor, M I; Benhal, P; Broda, A; Kulkarni, S; Malik, P; McCaffrey, B; Lafond, J-F; Nacev, A; Weinberg, I N; Shapiro, B; Depireux, D A

    2018-06-19

    This paper investigates the safety of a novel 'magnetic injection' method of delivering therapy to the cochlea, in a rodent model. In this method of administration, a magnetic field is employed to actively transport drug-eluting iron oxide-core nanoparticles into the cochlea, where they then release their drug payload (we delivered the steroid prednisolone). Our study design and selection of control groups was based on published regulatory guidance for safety studies that involve local drug delivery. We tested for both single and multiple delivery doses to the cochlea, and found that magnetic delivery did not harm hearing. There was no statistical difference in hearing between magnetically treated ears versus ears that received intra-tympanic steroid (a mimic of a standard-of-care for sudden sensorineural hearing loss), both 2 and 30 days after treatment. Since our treatment is local to the ear, the levels of steroid and iron circulating systemically after our treatment were low, below mass-spectrometry detection limits for the steroid and no different from normal for iron. No adverse findings were observed in ear tissue histopathology or in animal gross behavior. At 2 and 30 days after treatment, inflammatory changes in the ear were limited to the middle ear, were very mild in severity, and by day 90 there was ongoing and almost complete reversibility of these changes. There were no ear tissue scarring or hemorrhage trends associated with magnetic delivery. In summary, after conducting a pre-clinical safety study based on FDA guidance documents, no adverse safety issues were observed. Copyright © 2017. Published by Elsevier B.V.

  4. A new perspective on binaural integration using response time methodology: super capacity revealed in conditions of binaural masking release.

    PubMed

    Lentz, Jennifer J; He, Yuan; Townsend, James T

    2014-01-01

    This study applied reaction-time based methods to assess the workload capacity of binaural integration by comparing reaction time (RT) distributions for monaural and binaural tone-in-noise detection tasks. In the diotic contexts, an identical tone + noise stimulus was presented to each ear. In the dichotic contexts, an identical noise was presented to each ear, but the tone was presented to one of the ears 180° out of phase with respect to the other ear. Accuracy-based measurements have demonstrated a much lower signal detection threshold for the dichotic vs. the diotic conditions, but accuracy-based techniques do not allow for assessment of system dynamics or resource allocation across time. Further, RTs allow comparisons between these conditions at the same signal-to-noise ratio. Here, we apply a reaction-time based capacity coefficient, which provides an index of workload efficiency and quantifies the resource allocations for single ear vs. two ear presentations. We demonstrate that the release from masking generated by the addition of an identical stimulus to one ear is limited-to-unlimited capacity (efficiency typically less than 1), consistent with less gain than would be expected by probability summation. However, the dichotic presentation leads to a significant increase in workload capacity (increased efficiency)-most specifically at lower signal-to-noise ratios. These experimental results provide further evidence that configural processing plays a critical role in binaural masking release, and that these mechanisms may operate more strongly when the signal stimulus is difficult to detect, albeit still with nearly 100% accuracy.

  5. Asymmetric Hearing During Development: The Aural Preference Syndrome and Treatment Options.

    PubMed

    Gordon, Karen; Henkin, Yael; Kral, Andrej

    2015-07-01

    Deafness affects ∼2 in 1000 children and is one of the most common congenital impairments. Permanent hearing loss can be treated by fitting hearing aids. More severe to profound deafness is an indication for cochlear implantation. Although newborn hearing screening programs have increased the identification of asymmetric hearing loss, parents and caregivers of children with single-sided deafness are often hesitant to pursue therapy for the deaf ear. Delayed intervention has consequences for recovery of hearing. It has long been reported that asymmetric hearing loss/single-sided deafness compromises speech and language development and educational outcomes in children. Recent studies in animal models of deafness and in children consistently show evidence of an "aural preference syndrome" in which single-sided deafness in early childhood reorganizes the developing auditory pathways toward the hearing ear, with weaker central representation of the deaf ear. Delayed therapy consequently compromises benefit for the deaf ear, with slow rates of improvement measured over time. Therefore, asymmetric hearing needs early identification and intervention. Providing early effective stimulation in both ears through appropriate fitting of auditory prostheses, including hearing aids and cochlear implants, within a sensitive period in development has a cardinal role for securing the function of the impaired ear and for restoring binaural/spatial hearing. The impacts of asymmetric hearing loss on the developing auditory system and on spoken language development have often been underestimated. Thus, the traditional minimalist approach to clinical management aimed at 1 functional ear should be modified on the basis of current evidence. Copyright © 2015 by the American Academy of Pediatrics.

  6. A new perspective on binaural integration using response time methodology: super capacity revealed in conditions of binaural masking release

    PubMed Central

    Lentz, Jennifer J.; He, Yuan; Townsend, James T.

    2014-01-01

    This study applied reaction-time based methods to assess the workload capacity of binaural integration by comparing reaction time (RT) distributions for monaural and binaural tone-in-noise detection tasks. In the diotic contexts, an identical tone + noise stimulus was presented to each ear. In the dichotic contexts, an identical noise was presented to each ear, but the tone was presented to one of the ears 180° out of phase with respect to the other ear. Accuracy-based measurements have demonstrated a much lower signal detection threshold for the dichotic vs. the diotic conditions, but accuracy-based techniques do not allow for assessment of system dynamics or resource allocation across time. Further, RTs allow comparisons between these conditions at the same signal-to-noise ratio. Here, we apply a reaction-time based capacity coefficient, which provides an index of workload efficiency and quantifies the resource allocations for single ear vs. two ear presentations. We demonstrate that the release from masking generated by the addition of an identical stimulus to one ear is limited-to-unlimited capacity (efficiency typically less than 1), consistent with less gain than would be expected by probability summation. However, the dichotic presentation leads to a significant increase in workload capacity (increased efficiency)—most specifically at lower signal-to-noise ratios. These experimental results provide further evidence that configural processing plays a critical role in binaural masking release, and that these mechanisms may operate more strongly when the signal stimulus is difficult to detect, albeit still with nearly 100% accuracy. PMID:25202254

  7. A Solution on Identification and Rearing Files Insmallhold Pig Farming

    NASA Astrophysics Data System (ADS)

    Xiong, Benhai; Fu, Runting; Lin, Zhaohui; Luo, Qingyao; Yang, Liang

    In order to meet government supervision of pork production safety as well as consumeŕs right to know what they buy, this study adopts animal identification, mobile PDA reader, GPRS and other information technologies, and put forward a data collection method to set up rearing files of pig in smallhold pig farming, and designs related metadata structures and its mobile database, and develops a mobile PDA embedded system to collect individual information of pig and uploading into the remote central database, and finally realizes mobile links to the a specific website. The embedded PDA can identify both a special pig bar ear tag appointed by the Ministry of Agricultural and a general data matrix bar ear tag designed by this study by mobile reader, and can record all kinds of inputs data including bacterins, feed additives, animal drugs and even some forbidden medicines and submitted them to the center database through GPRS. At the same time, the remote center database can be maintained by mobile PDA and GPRS, and finally reached pork tracking from its origin to consumption and its tracing through turn-over direction. This study has suggested a feasible technology solution how to set up network pig electronic rearing files involved smallhold pig farming based on farmer and the solution is proved practical through its application in the Tianjińs pork quality traceability system construction. Although some individual techniques have some adverse effects on the system running such as GPRS transmitting speed now, these will be resolved with the development of communication technology. The full implementation of the solution around China will supply technical supports in guaranteeing the quality and safety of pork production supervision and meet consumer demand.

  8. STS-40 MS Jernigan, working at SLS-1 Rack 1, examines Pilot Gutierrez's ear

    NASA Image and Video Library

    1991-06-14

    STS040-206-002 (5-14 June 1991) --- Held in place by the Spacelab Life Sciences (SLS-1) Medical Restraint System (MRS), astronaut Sidney M. Gutierrez, pilot, gets his ears checked by astronaut Tamara E. Jernigan, mission specialist. The two are in the SLS-1 module, onboard the Space Shuttle Columbia. The scene was photographed with a 35mm camera.

  9. The MOC reflex during active listening to speech.

    PubMed

    Garinis, Angela C; Glattke, Theodore; Cone, Barbara K

    2011-10-01

    The purpose of this study was to test the hypothesis that active listening to speech would increase medial olivocochlear (MOC) efferent activity for the right vs. the left ear. Click-evoked otoacoustic emissions (CEOAEs) were evoked by 60-dB p.e. SPL clicks in 13 normally hearing adults in 4 test conditions for each ear: (a) in quiet; (b) with 60-dB SPL contralateral broadband noise; (c) with words embedded (at -3-dB signal-to-noise ratio [SNR]) in 60-dB SPL contralateral noise during which listeners directed attention to the words; and (d) for the same SNR as in the 3rd condition, with words played backwards. There was greater suppression during active listening compared with passive listening that was apparent in the latency range of 6- to 18-ms poststimulus onset. Ear differences in CEOAE amplitude were observed in all conditions, with right-ear amplitudes larger than those for the left. The absolute difference between CEOAE amplitude in quiet and with contralateral noise, a metric of suppression, was equivalent for right and left ears. When the amplitude differences were normalized, suppression was greater for noise presented to the right and the effect measured for a probe in the left ear. The findings support the theory that cortical mechanisms involved in listening to speech affect cochlear function through the MOC efferent system.

  10. Evolution and development of the vertebrate ear

    NASA Technical Reports Server (NTRS)

    Fritzsch, B.; Beisel, K. W.

    2001-01-01

    This review outlines major aspects of development and evolution of the ear, specifically addressing issues of cell fate commitment and the emerging molecular governance of these decisions. Available data support the notion of homology of subsets of mechanosensors across phyla (proprioreceptive mechanosensory neurons in insects, hair cells in vertebrates). It is argued that this conservation is primarily related to the specific transducing environment needed to achieve mechanosensation. Achieving this requires highly conserved transcription factors that regulate the expression of the relevant structural genes for mechanosensory transduction. While conserved at the level of some cell fate assignment genes (atonal and its mammalian homologue), the ear has also radically reorganized its development by implementing genes used for cell fate assignment in other parts of the developing nervous systems (e.g., neurogenin 1) and by evolving novel sets of genes specifically associated with the novel formation of sensory neurons that contact hair cells (neurotrophins and their receptors). Numerous genes have been identified that regulate morphogenesis, but there is only one common feature that emerges at the moment: the ear appears to have co-opted genes from a large variety of other parts of the developing body (forebrain, limbs, kidneys) and establishes, in combination with existing transcription factors, an environment in which those genes govern novel, ear-related morphogenetic aspects. The ear thus represents a unique mix of highly conserved developmental elements combined with co-opted and newly evolved developmental elements.

  11. Femtosecond laser ablation of the stapes

    NASA Astrophysics Data System (ADS)

    McCaughey, Ryan G.; Sun, Hui; Rothholtz, Vanessa S.; Juhasz, Tibor; Wong, Brian J. F.

    2009-03-01

    A femtosecond laser, normally used for LASIK eye surgery, is used to perforate cadaveric human stapes. The thermal side effects of bone ablation are measured with a thermocouple in an inner ear model and are found to be within acceptable limits for inner ear surgery. Stress and acoustic events, recorded with piezoelectric film and a microphone, respectively, are found to be negligible. Optical microscopy, scanning electron microscopy, and optical coherence tomography are used to confirm the precision of the ablation craters and lack of damage to the surrounding tissue. Ablation is compared to that from an Er:YAG laser, the current laser of choice for stapedotomy, and is found to be superior. Ultra-short-pulsed lasers offer a precise and efficient ablation of the stapes, with minimal thermal and negligible mechanical and acoustic damage. They are, therefore, ideal for stapedotomy operations.

  12. Diverse patterns of perilymphatic space enhancement in the rat inner ear after intratympanic injection of two different types of gadolinium: a 9.4-tesla magnetic resonance study.

    PubMed

    Park, Mina; Lee, Ho Sun; Choi, Jun-Jae; Kim, Hyeonjin; Lee, Jun Ho; Oh, Seung Ha; Suh, Myung-Whan

    2015-01-01

    To compare the quality of perilymphatic enhancement in the rat inner ear after intratympanic injection of two types of gadolinium with a 9.4-tesla micro-MRI. Gadolinium was injected into the middle ear in 6 Sprague-Dawley rats via the transtympanic route. The left ear was injected with Gd-DO3A-butrol first, and then the right ear was injected with Gd-DOTA. MR images of the inner ear were acquired 1.0, 1.5, 2.0, 2.5, 3.0, 3.5, and 4 h after intratympanic (IT) injection using an Agilent MRI system 9.4T/160/AS. The normalized signal intensity was quantitatively analyzed at the scala vestibuli (SV), scala media, and scala tympani (ST) using a Marosis M-view system. Then the normalized signal intensities (SIs) were compared between the two contrast agents. For Gd-DO3A-butrol, the SI was as low as 1.0-1.5 throughout 1-4 h at the SV and ST of the basal turn. The maximum SI was 1.5 ± 0.5 at the SV (2 h) and 1.3 ± 0.5 at the ST (2 h). For Gd-DOTA, the 1-hour postinjection SI at the basal turn was 2.5 ± 0.5 at the SV, 1.6 ± 0.3 at the ST, and 1.2 ± 0.3 at the scala media. In the apical turn, the maximum SI was reached after 2.5 h. The maximum SI in the apical turn was 1.8 ± 0.4 at the SV (3.5 h), 1.8 ± 0.4 at the ST (4 h), and 1.4 ± 0.3 at the scala media (4 h). We were able to clearly visualize and separate the ST and SV using IT Gd and 9.4-tesla micro-MRI. We recommend using Gd-DO3A-butrol over Gd-DOTA and to perform the MRI 2.5 h after using IT Gd in the rat inner ear. © 2015 S. Karger AG, Basel.

  13. New optical tomographic & topographic techniques for biomedical applications

    NASA Astrophysics Data System (ADS)

    Buytaert, Jan

    The mammalian middle ear contains the eardrum and the three auditory ossicles, and forms an impedance match between sound in air and pressure waves in the fluid of the inner ear. Without this intermediate system, with its unsurpassed efficiency and dynamic range, we would be practically deaf. Physics-based modeling of this extremely complex mechanical system is necessary to help our basic understanding of the functioning of hearing. Highly realistic models will make it possible to predict the outcome of surgical interventions and to optimize design of ossicle prostheses and active middle ear implants. To obtain such models and with realistic output, basic input data is still missing. In this dissertation I developed and used two new optical techniques to obtain two essential sets of data: accurate three-dimensional morphology of the middle ear structures, and elasticity parameters of the eardrum. The first technique is a new method for optical tomography of macroscopic biomedical objects, which makes it possible to measure the three-dimensional geometry of the middle ear ossicles and soft tissues which are connecting and suspending them. I made a new and high-resolution version of this orthogonal-plane fluorescence optical sectioning method, to obtain micrometer resolution in macroscopic specimens. The result is thus a complete 3-D model of the middle (and inner) ear of gerbil in unprecedented quality. On top of high-resolution morphological models of the middle ear structures, I applied the technique in other fields of research as well. The second device works according to a new optical profilometry technique which allows to measure shape and deformations of the eardrum and other membranes or objects. The approach is called projection moire profilometry, and creates moire interference fringes which contain the height information. I developed a setup which uses liquid crystal panels for grid projection and optical demodulation. Hence no moving parts are present and the setup is entirely digitally controlled. This measurement method is developed to determine the elasticity parameters of the eardrum in-situ. Other surface shapes however can also be measured.

  14. [Effect size on resonance of the outer ear canal by simulation of middle ear lesions using a temporal bone preparation].

    PubMed

    Scheinpflug, L; Vorwerk, U; Begall, K

    1995-01-01

    By means of a model of the external and the middle ear it is possible to simulate various, exactly defined pathological conditions of the middle ear and to describe their influence on ear canal resonance. Starting point of the investigations are fresh postmortem preparations of 8 human temporal bones with an intact ear drum and a retained skin of the ear canal. The compliance of the middle ear does not significantly differ from the clinical data of probands with healthy ears. After antrotomy it is possible to simulate pathological conditions of the middle ear one after the other at the same temporal bone. The influence of the changed middle ear conditions on ear drum compliance, ear canal volume and on the resonance curve of the external ear canal was investigated. For example, the middle ear was filled with water to create approximately the same conditions as in acute serous otitis media. In this middle ear condition a significant increase of the sound pressure amplification was found, on an average by 4 decibels compared to the unchanged temporal bone model. A small increase in resonance frequency was also measured. The advantages of this model are the approximately physiological conditions and the constant dimensions of the external and middle ear.

  15. A real-time data acquisition and control of gradient coil noise for fMRI identification of hearing disorder in children with history of ear infection.

    PubMed

    Lee, Jaeseung; Holte, James; Ritenour, E Russell

    2013-02-01

    Early ear infection and trauma, from birth to age 12 are known to have a significant effect on sensory and cognitive development. This effect can be demonstrated through the fMRI study of children who have a history of ear infection compared to a control group. A second research question is the extent to which brain plasticity at an early age can reduce the impact of infection on hearing and cognitive development. Functional Magnetic Resonance Imaging (fMRI) provides a mapping of brain activity in cognitive and sensory regions by recording the oxygenation state of the local cerebral blood flow. The gradient coils of fMRI scanners generate intense acoustic noise (GCN) - to which the subject is in close proximity - in the range of 90 to 140 db SPL during the imaging process. Clearly this noise will impress its signature on low level brain response patterns. An Active Noise Canceller (ANC) system can suppress the effect of GCN on the subject's perception of a phonetic stimulus at the phoneme, word or phrase level. Due to a superimposition of the frequency and time domain components of the test signal and GCN for MR test, the ANC filtering system performs its function in real time - we must capture the brain's response to the test signal AFTER the noise has been removed. This goal is achieved through the application of field programmable gate array (FPGA) technology of NI LabVIEW. The presentation (in the noisy fMRI environment) of test words and phrases to hearing impaired children can identify sources of distortion to their perceptual processes associated with GCN. Once this distortion has been identified, learning strategies may be introduced to replace the hearing function distorted by early infection as well as the short term effect of GCN. The study of speech cognition without the confounding effect of GCN and with the varying level of GCN for a repeated test signal at later age can be allowed to a measure of recovery through brain plasticity.

  16. A real-time data acquisition and control of gradient coil noise for fMRI identification of hearing disorder in children with history of ear infection

    PubMed Central

    Lee, Jaeseung; Holte, James

    2013-01-01

    Early ear infection and trauma, from birth to age 12 are known to have a significant effect on sensory and cognitive development. This effect can be demonstrated through the fMRI study of children who have a history of ear infection compared to a control group. A second research question is the extent to which brain plasticity at an early age can reduce the impact of infection on hearing and cognitive development. Functional Magnetic Resonance Imaging (fMRI) provides a mapping of brain activity in cognitive and sensory regions by recording the oxygenation state of the local cerebral blood flow. The gradient coils of fMRI scanners generate intense acoustic noise (GCN) - to which the subject is in close proximity - in the range of 90 to 140 db SPL during the imaging process. Clearly this noise will impress its signature on low level brain response patterns. An Active Noise Canceller (ANC) system can suppress the effect of GCN on the subject’s perception of a phonetic stimulus at the phoneme, word or phrase level. Due to a superimposition of the frequency and time domain components of the test signal and GCN for MR test, the ANC filtering system performs its function in real time - we must capture the brain’s response to the test signal AFTER the noise has been removed. This goal is achieved through the application of field programmable gate array (FPGA) technology of NI LabVIEW. The presentation (in the noisy fMRI environment) of test words and phrases to hearing impaired children can identify sources of distortion to their perceptual processes associated with GCN. Once this distortion has been identified, learning strategies may be introduced to replace the hearing function distorted by early infection as well as the short term effect of GCN. The study of speech cognition without the confounding effect of GCN and with the varying level of GCN for a repeated test signal at later age can be allowed to a measure of recovery through brain plasticity. PMID:23482910

  17. Choice of probe tone and classification of trace patterns in tympanometry undertaken in early infancy.

    PubMed

    Baldwin, Margaret

    2006-07-01

    Tympanometry using 226 Hz, 678 Hz, and 1000 Hz probe tones was undertaken on two groups of babies, age 2 to 21 weeks. A group of 104 babies with normal ABR thresholds or TEOAEs were compared with a second group of 107 babies who had evidence of temporary conductive hearing loss based on the findings of a test battery, which included air and bone conduction ABR. The tympanograms were classified by Method 1, a simple visual classification system, and Method 2, adapted from a system described by Marchant et al (1986). The majority of tympanograms recorded in both groups using the 226 Hz probe tone were 'normal' Type A, with no significant difference in middle ear pressure or static admittance. However, both classification methods demonstrated significant differences between the two groups using the higher frequency probe tones, with Method 2 being the preferred system of classification. Tympanometry using 226 Hz is invalid below 21 weeks and 1000 Hz is the frequency of choice.

  18. Chronic Tuberculous Otomastoiditis: A Case Report.

    PubMed

    Bruschini, Luca; Ciabotti, Annalisa; Berrettini, Stefano

    2016-08-01

    Worldwide, tuberculosis is a widespread disease, with 8.7 million new cases occurring annually. Its etiologic agent, Mycobacterium tuberculosis, essentially causes pneumonia. However, this organism affects the middle ear in rare cases, accounting for 0.04-0.09% of all chronic middle ear otitis cases in Western countries. In this report, we describe the case of a young woman affected by tuberculosis of the middle ear. In our experience, empiric therapy was not beneficial. Adequate treatment was possible only after obtaining a specific diagnosis through a difficult process requiring surgical sampling for culture examination. We consider surgical sampling to be mandatory in all cases of chronic otitis media that do not respond to prolonged systemic and local therapies.

  19. Technical note: Validation of an ear-tag accelerometer sensor to determine rumination, eating, and activity behaviors of grazing dairy cattle.

    PubMed

    Pereira, G M; Heins, B J; Endres, M I

    2018-03-01

    The objective of this study was to validate an ear-tag accelerometer sensor (CowManager SensOor, Agis Automatisering BV, Harmelen, the Netherlands) using direct visual observations in a grazing dairy herd. Lactating crossbred cows (n = 24) were used for this experiment at the University of Minnesota West Central Research and Outreach Center grazing dairy (Morris, MN) during the summer of 2016. A single trained observer recorded behavior every minute for 6 h for each cow (24 cows × 6 h = 144 h of observation total). Direct visual observation was compared with sensor data during August and September 2016. The sensor detected and identified ear and head movements, and through algorithms the sensor classified each minute as one of the following behaviors: rumination, eating, not active, active, and high active. A 2-sided t-test was conducted with PROC TTEST of SAS (SAS Institute Inc., Cary, NC) to compare the percentage of time each cow's behavior was recorded by direct visual observation and sensor data. For total recorded time, the percentage of time of direct visual observation compared with sensor data was 17.9 and 19.1% for rumination, 52.8 and 51.9% for eating, 17.4 and 11.9% for not active, and 7.9 and 21.1% for active. Pearson correlations (PROC CORR of SAS) were used to evaluate associations between direct visual observations and sensor data. Furthermore, concordance correlation coefficient (CCC), bias correction factors, location shift, and scale shift (epiR package of R version 3.3.1; R Foundation for Statistical Computing, Vienna, Austria) were calculated to provide a measure of accuracy and precision. Correlations between visual observations for all 4 behaviors were highly to weakly correlated (rumination: r = 0.72, CCC = 0.71; eating: r = 0.88, CCC = 0.88; not active: r = 0.65, CCC = 0.52; and active: r = 0.20, CCC = 0.19) compared with sensor data. The results suggest that the sensor accurately monitors rumination and eating behavior of grazing dairy cattle. However, active behaviors may be more difficult for the sensor to record than others. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  20. Position-dependent hearing in three species of bushcrickets (Tettigoniidae, Orthoptera)

    PubMed Central

    Lakes-Harlan, Reinhard; Scherberich, Jan

    2015-01-01

    A primary task of auditory systems is the localization of sound sources in space. Sound source localization in azimuth is usually based on temporal or intensity differences of sounds between the bilaterally arranged ears. In mammals, localization in elevation is possible by transfer functions at the ear, especially the pinnae. Although insects are able to locate sound sources, little attention is given to the mechanisms of acoustic orientation to elevated positions. Here we comparatively analyse the peripheral hearing thresholds of three species of bushcrickets in respect to sound source positions in space. The hearing thresholds across frequencies depend on the location of a sound source in the three-dimensional hearing space in front of the animal. Thresholds differ for different azimuthal positions and for different positions in elevation. This position-dependent frequency tuning is species specific. Largest differences in thresholds between positions are found in Ancylecha fenestrata. Correspondingly, A. fenestrata has a rather complex ear morphology including cuticular folds covering the anterior tympanal membrane. The position-dependent tuning might contribute to sound source localization in the habitats. Acoustic orientation might be a selective factor for the evolution of morphological structures at the bushcricket ear and, speculatively, even for frequency fractioning in the ear. PMID:26543574

Top