Sample records for recovery matrix effects

  1. Matrix effects in pesticide multi-residue analysis by liquid chromatography-mass spectrometry.

    PubMed

    Kruve, Anneli; Künnapas, Allan; Herodes, Koit; Leito, Ivo

    2008-04-11

    Three sample preparation methods: Luke method (AOAC 985.22), QuEChERS (quick, easy, cheap, effective, rugged and safe) and matrix solid-phase dispersion (MSPD) were applied to different fruits and vegetables for analysis of 14 pesticide residues by high-performance liquid chromatography with electrospray ionization-mass spectrometry (HPLC/ESI/MS). Matrix effect, recovery and process efficiency of the sample preparation methods applied to different fruits and vegetables were compared. The Luke method was found to produce least matrix effect. On an average the best recoveries were obtained with the QuEChERS method. MSPD gave unsatisfactory recoveries for some basic pesticide residues. Comparison of matrix effects for different apple varieties showed high variability for some residues. It was demonstrated that the amount of co-extracting compounds that cause ionization suppression of aldicarb depends on the apple variety as well as on the sample preparation method employed.

  2. Matrix effect and recovery terminology issues in regulated drug bioanalysis.

    PubMed

    Huang, Yong; Shi, Robert; Gee, Winnie; Bonderud, Richard

    2012-02-01

    Understanding the meaning of the terms used in the bioanalytical method validation guidance is essential for practitioners to implement best practice. However, terms that have several meanings or that have different interpretations exist within bioanalysis, and this may give rise to differing practices. In this perspective we discuss an important but often confusing term - 'matrix effect (ME)' - in regulated drug bioanalysis. The ME can be interpreted as either the ionization change or the measurement bias of the method caused by the nonanalyte matrix. The ME definition dilemma makes its evaluation challenging. The matrix factor is currently used as a standard method for evaluation of ionization changes caused by the matrix in MS-based methods. Standard additions to pre-extraction samples have been suggested to evaluate the overall effects of a matrix from different sources on the analytical system, because it covers ionization variation and extraction recovery variation. We also provide our personal views on the term 'recovery'.

  3. Percent recoveries of anthropogenic organic compounds with and without the addition of ascorbic acid to preserve finished-water samples containing free chlorine, 2004-10

    USGS Publications Warehouse

    Valder, Joshua F.; Delzer, Gregory C.; Bender, David A.; Price, Curtis V.

    2011-01-01

    This report presents finished-water matrix-spike recoveries of 270 anthropogenic organic compounds with and without the addition of ascorbic acid to preserve water samples containing free chlorine. Percent recoveries were calculated using analytical results from a study conducted during 2004-10 for the National Water-Quality Assessment (NAWQA) Program of the U.S. Geological Survey (USGS). The study was intended to characterize the effect of quenching on finished-water matrix-spike recoveries and to better understand the potential oxidation and transformation of 270 anthropogenic organic compounds. The anthropogenic organic compounds studied include those on analytical schedules 1433, 2003, 2033, 2060, 2020, and 4024 of the USGS National Water Quality Laboratory. Three types of samples were collected from 34 NAWQA locations across the Nation: (1) quenched finished-water samples (not spiked), (2) quenched finished-water matrix-spike samples, and (3) nonquenched finished-water matrix-spike samples. Percent recoveries of anthropogenic organic compounds in quenched and nonquenched finished-water matrix-spike samples are presented. Comparisons of percent recoveries between quenched and nonquenched spiked samples can be used to show how quenching affects finished-water samples. A maximum of 18 surface-water and 34 groundwater quenched finished-water matrix-spike samples paired with nonquenched finished-water matrix-spike samples were analyzed. Percent recoveries for the study are presented in two ways: (1) finished-water matrix-spike samples supplied by surface-water or groundwater, and (2) by use (or source) group category for surface-water and groundwater supplies. Graphical representations of percent recoveries for the quenched and nonquenched finished-water matrix-spike samples also are presented.

  4. Volatile organic compound matrix spike recoveries for ground- and surface-water samples, 1997-2001

    USGS Publications Warehouse

    Rowe, Barbara L.; Delzer, Gregory C.; Bender, David A.; Zogorski, John S.

    2005-01-01

    The U.S. Geological Survey's National Water-Quality Assessment (NAWQA) Program used field matrix spikes (FMSs), field matrix spike replicates (FMSRs), laboratory matrix spikes (LMSs), and laboratory reagent spikes (LRSs), in part, to assess the quality of volatile organic compound (VOC) data from water samples collected and analyzed in more than 50 of the Nation's largest river basins and aquifers (Study Units). The data-quality objectives of the NAWQA Program include estimating the extent to which variability, degradation, and matrix effects, if any, may affect the interpretation of chemical analyses of ground- and surface-water samples. In order to help meet these objectives, a known mass of VOCs was added (spiked) to water samples collected in 25 Study Units. Data within this report include recoveries from 276 ground- and surface-water samples spiked with a 25-microliter syringe with a spike solution containing 85 VOCs to achieve a concentration of 0.5 microgram per liter. Combined recoveries for 85 VOCs from spiked ground- and surface-water samples and reagent water were used to broadly characterize the overall recovery of VOCs. Median recoveries for 149 FMSs, 107 FMSRs, 20 LMSs, and 152 LRSs were 79.9, 83.3, 113.1, and 103.5 percent, respectively. Spike recoveries for 85 VOCs also were calculated individually. With the exception of a few VOCs, the median percent recoveries determined from each spike type for individual VOCs followed the same pattern as for all VOC recoveries combined, that is, listed from least to greatest recovery-FMSs, FMSRs, LRSs, and LMSs. The median recoveries for individual VOCs ranged from 63.7 percent to 101.5 percent in FMSs; 63.1 percent to 101.4 percent in FMSRs; 101.7 percent to 135.0 percent in LMSs; and 91.0 percent to 118.7 percent in LRSs. Additionally, individual VOC recoveries were compared among paired spike types, and these recoveries were used to evaluate potential bias in the method. Variability associated with field spiking, field handling, transport, and analysis was assessed by comparing recoveries between 107 pairs of FMR and FMSR samples. For most VOCs, FMSR recoveries were greater than the paired FMS recoveries. This may result from routinely processing the FMS sample first, allowing a more fluid and efficient technique when processing the FMSR. Degradation was examined by comparing VOC recoveries between 20 pairs of FMS and LMS samples. For all VOCs, the LMS recoveries were greater than FMS recoveries. However, data presented in a previously published VOC stability study were interpreted, and recoveries indicated that VOC degradation should not affect the recovery for most VOCs monitored by the NAWQA Program. Matrix effects were examined by comparing VOC recoveries from 20 pairs of LMS and LRS samples. With the exception of two VOCs, individual recoveries were not significantly different between LMSs and LRSs, indicating that most VOC recoveries are not affected by matrix effects. Additionally, matrix effects should be negligible due to the analytical technique (purge and trap capillary column gas chromatography/mass spectrometry) used for VOC analysis at the U.S. Geological Survey National Water Quality Laboratory (NWQL). The reason for the lower VOC recoveries from FMSs and FMSRs than from LMSs and LRSs may be associated with differences in spiking technique and experience, and to varying environmental conditions at the time of spiking. However, for all spike types, 87 percent of the individual VOC recoveries were within the range of 60 to 140 percent, a range that is considered acceptable by the U.S. Environmental Protection Agency's established analytical method. Additionally, the median recovery for each spike type was within the range of 60 to 140 percent. The excellent VOC recoveries from LMSs and LRSs demonstrate that low VOC concentrations can routinely and accurately be measured by the analytical methods used by the NWQL.

  5. Ambiguity in measuring matrix diffusion with single-well injection/recovery tracer tests

    USGS Publications Warehouse

    Lessoff, S.C.; Konikow, Leonard F.

    1997-01-01

    Single-well injection/recovery tracer tests are considered for use in characterizing and quantifying matrix diffusion in dual-porosity aquifers. Numerical modeling indicates that neither regional drift in homogeneous aquifers, nor heterogeneity in aquifers having no regional drift, nor hydrodynamic dispersion significantly affects these tests. However, when drift is coupled simultaneously with heterogeneity, they can have significant confounding effects on tracer return. This synergistic effect of drift and heterogeneity may help explain irreversible flow and inconsistent results sometimes encountered in previous single-well injection/recovery tracer tests. Numerical results indicate that in a hypothetical single-well injection/recovery tracer test designed to demonstrate and measure dual-porosity characteristics in a fractured dolomite, the simultaneous effects of drift and heterogeneity sometimes yields responses similar to those anticipated in a homogeneous dual-porosity formation. In these cases, tracer recovery could provide a false indication of the occurrence of matrix diffusion. Shortening the shut-in period between injection and recovery periods may make the test less sensitive to drift. Using multiple tracers having different diffusion characteristics, multiple tests having different pumping schedules, and testing the formation at more than one location would decrease the ambiguity in the interpretation of test data.

  6. The Role of Species Traits in Mediating Functional Recovery during Matrix Restoration

    PubMed Central

    Barnes, Andrew D.; Emberson, Rowan M.; Krell, Frank-Thorsten; Didham, Raphael K.

    2014-01-01

    Reversing anthropogenic impacts on habitat structure is frequently successful through restoration, but the mechanisms linking habitat change, community reassembly and recovery of ecosystem functioning remain unknown. We test for the influence of edge effects and matrix habitat restoration on the reassembly of dung beetle communities and consequent recovery of dung removal rates across tropical forest edges. Using path modelling, we disentangle the relative importance of community-weighted trait means and functional trait dispersion from total biomass effects on rates of dung removal. Community trait composition and biomass of dung beetle communities responded divergently to edge effects and matrix habitat restoration, yielding opposing effects on dung removal. However, functional dispersion—used in this study as a measure of niche complementarity—did not explain a significant amount of variation in dung removal rates across habitat edges. Instead, we demonstrate that the path to functional recovery of these altered ecosystems depends on the trait-mean composition of reassembling communities, over and above purely biomass-dependent processes that would be expected under neutral theory. These results suggest that any ability to manage functional recovery of ecosystems during habitat restoration will demand knowledge of species' roles in ecosystem processes. PMID:25502448

  7. The role of species traits in mediating functional recovery during matrix restoration.

    PubMed

    Barnes, Andrew D; Emberson, Rowan M; Krell, Frank-Thorsten; Didham, Raphael K

    2014-01-01

    Reversing anthropogenic impacts on habitat structure is frequently successful through restoration, but the mechanisms linking habitat change, community reassembly and recovery of ecosystem functioning remain unknown. We test for the influence of edge effects and matrix habitat restoration on the reassembly of dung beetle communities and consequent recovery of dung removal rates across tropical forest edges. Using path modelling, we disentangle the relative importance of community-weighted trait means and functional trait dispersion from total biomass effects on rates of dung removal. Community trait composition and biomass of dung beetle communities responded divergently to edge effects and matrix habitat restoration, yielding opposing effects on dung removal. However, functional dispersion--used in this study as a measure of niche complementarity--did not explain a significant amount of variation in dung removal rates across habitat edges. Instead, we demonstrate that the path to functional recovery of these altered ecosystems depends on the trait-mean composition of reassembling communities, over and above purely biomass-dependent processes that would be expected under neutral theory. These results suggest that any ability to manage functional recovery of ecosystems during habitat restoration will demand knowledge of species' roles in ecosystem processes.

  8. Chemical, Calcium Phosphate Cements for Geothermal Wells - Corrosion Protection, Bond Strength and Matrix Self-Healing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sugama, Toshifumi

    The data set shows performance of economical calcium phosphate cement (Fondu) blended with fly ash, class F (FAF) in carbon steel corrosion protection tests (corrosion rate, corrosion current and potential), bond- and matrix strength, as well as matrix strength recovery after imposed damage at 300C. The corrosion protection and lap-shear bond strength data are given for different Fondu/FAF ratios, the matrix strength data recoveries are reported for 60/40 weight % Fondu/FAF ratios. Effect of sodium phosphate on bond strength, corrosion protection and self-healing is demonstrated.

  9. Enhancement of ethylenethiourea recoveries in food analyses by addition of cysteine hydrochloride.

    PubMed

    Sack, C A

    1995-01-01

    The effectiveness of cysteine hydrochloride (Cys-HCl) as a preservative of ethylenethiourea (ETU) in product matrixes and during analysis was studied. ETU recoveries were adversely affected by certain product matrixes when fortified directly into the product. Recoveries in 8 selected food items were 0-92% when analyzed 30 min after fortification and 0-51% when analyzed after 24 h. When Cys-HCl was added to product prior to fortification, recoveries increased to 71-95% even after frozen storage for 2-4 weeks. Cys-HCl was added during analysis of 53 untreated items. Recoveries improved an average of 15% with Cys-HCl. Without Cys-HCl, recoveries were erratic (20-98%), but with Cys-HCl, recoveries were 68-113%. Other antioxidants (sodium sulfite, butylated hydroxyanisole, butylated hydroxytoluene, and vitamins A and C) also were evaluated as ETU preservatives. When lettuce was treated first with sodium sulfite and then fortified with ETU, recoveries averaged 86%; without sodium sulfite, they averaged 1%. The other antioxidants were less effective for preserving ETU in lettuce, giving only 8-46% recoveries. The effect of oxidizers (potassium bromate, sodium hypochlorite, and hydrogen peroxide) on ETU recovery was also determined. Recovery of ETU from a baby food product (pears and pineapple) was 82%; with oxidizers, recoveries were 0-8%.

  10. Phase-field simulation of counter-current spontaneous imbibition in a fractured heterogeneous porous medium

    NASA Astrophysics Data System (ADS)

    Rokhforouz, M. R.; Akhlaghi Amiri, H. A.

    2017-06-01

    Spontaneous imbibition is well-known to be one of the most effective processes of oil recovery in fractured reservoirs. However, the detailed pore-scale mechanisms of the counter-current imbibition process and the effects of different fluid/rock parameters on this phenomenon have not yet been deeply addressed. This work presents the results of a new pore-level numerical study of counter-current spontaneous imbibition, using coupled Cahn-Hilliard phase field and Navier-Stokes equations, solved by a finite element method. A 2D fractured medium was constructed consisting of a nonhomogeneous porous matrix, in which the grains were represented by an equilateral triangular array of circles with different sizes and initially saturated with oil, and a fracture, adjacent to the matrix, initially saturated with water and supported by low rate water inflow. Through invasion of water into the matrix, oil drops were expelled one by one from the matrix to the fracture, and in the matrix, water progressed by forming capillary fingerings, with characteristics corresponding to the experimental observations. The effects of wettability, viscosity ratio, and interfacial tension were investigated. In strongly water-wet matrix, with grain contact angles of θ < π/8, different micro-scale mechanisms were successfully captured, including oil film thinning and rupture, fluids' contact line movement, water bridging, and oil drop detachment. It was notified that there was a specific grain contact angle for this simulated model, θ = π/4, above it, matrix oil recovery was negligible by imbibition, while below it, the imbibition rate and oil recovery were significantly increased by decreasing the contact angle. In simulated mixed wet models, water, coming from the fracture, just invaded the neighboring water-wet grains; the water front was stopped moving as it met the oil-wet grains or wide pores/throats. Increasing water-oil interfacial tension, in the range of 0.005-0.05 N/m, resulted in both higher rate of imbibition and higher ultimate oil recovery. Changing the water-oil viscosity ratio (M), in the range of 0.1-10, had a negligible effect on the imbibition rate, while due to co-effects of capillary fingering and viscous mobility ratio, the model with M = 1 had relatively higher ultimate oil recovery.

  11. Effect of processing on recovery and variability associated with immunochemical analytical methods for multiple allergens in a single matrix: sugar cookies.

    PubMed

    Khuda, Sefat; Slate, Andrew; Pereira, Marion; Al-Taher, Fadwa; Jackson, Lauren; Diaz-Amigo, Carmen; Bigley, Elmer C; Whitaker, Thomas; Williams, Kristina M

    2012-05-02

    Among the major food allergies, peanut, egg, and milk are the most common. The immunochemical detection of food allergens depends on various factors, such as the food matrix and processing method, which can affect allergen conformation and extractability. This study aimed to (1) develop matrix-specific incurred reference materials for allergen testing, (2) determine whether multiple allergens in the same model food can be simultaneously detected, and (3) establish the effect of processing on reference material stability and allergen detection. Defatted peanut flour, whole egg powder, and spray-dried milk were added to cookie dough at seven incurred levels before baking. Allergens were measured using five commercial enzyme-linked immunosorbent assay (ELISA) kits. All kits showed decreased recovery of all allergens after baking. Analytical coefficients of variation for most kits increased with baking time, but decreased with incurred allergen level. Thus, food processing negatively affects the recovery and variability of peanut, egg, and milk detection in a sugar cookie matrix when using immunochemical methods.

  12. Adaptive composites with embedded NiTiCu wires

    NASA Astrophysics Data System (ADS)

    Balta-Neumann, J. Antonio; Michaud, Veronique J.; Parlinska, Magdelena; Gotthardt, Rolf; Manson, Jan-Anders E.

    2001-07-01

    Adaptive composites have been produced by embedding prestrained shape memory alloy (SMA) wires into an epoxy matrix, reinforced with aramid fibers. These materials demonstrate attractive effects such as shape change or a shift in the vibration frequency upon activation. When heated above their transformation temperature, the wires' strain recovery is confined, and recovery stresses are generated. As a result, if the wires are placed along the neutral axis of a composite beam, a shift in resonance vibration frequency can be observed. To optimize the design of such composites, the matrix - SMA wire interfacial shear strength has been analyzed with the pull out testing technique. It is shown that the nature of the wire surface influences the interfacial shear strength, and that satisfactory results are obtained for SMA wires with a thin oxide layer. Composite samples consisting of two different types of pre- strained NiTiCu wires embedded in either pure epoxy matrix or Kevlar-epoxy matrix were produced. The recovery force and vibration response of composites were measured in a clamped-clamped configuration, to assess the effect of wire type and volume fraction. The results are highly reproducible in all cases with a narrow hysteresis loop, which makes NiTiCu wires good candidates for adaptive composites. The recovery forces increase with the volume fraction of the embedded wires, are higher when the wires are embedded in a low CTE matrix and, at a given temperature, are higher when the wire transformation temperature is lower.

  13. Near-optimal matrix recovery from random linear measurements.

    PubMed

    Romanov, Elad; Gavish, Matan

    2018-06-25

    In matrix recovery from random linear measurements, one is interested in recovering an unknown M-by-N matrix [Formula: see text] from [Formula: see text] measurements [Formula: see text], where each [Formula: see text] is an M-by-N measurement matrix with i.i.d. random entries, [Formula: see text] We present a matrix recovery algorithm, based on approximate message passing, which iteratively applies an optimal singular-value shrinker-a nonconvex nonlinearity tailored specifically for matrix estimation. Our algorithm typically converges exponentially fast, offering a significant speedup over previously suggested matrix recovery algorithms, such as iterative solvers for nuclear norm minimization (NNM). It is well known that there is a recovery tradeoff between the information content of the object [Formula: see text] to be recovered (specifically, its matrix rank r) and the number of linear measurements n from which recovery is to be attempted. The precise tradeoff between r and n, beyond which recovery by a given algorithm becomes possible, traces the so-called phase transition curve of that algorithm in the [Formula: see text] plane. The phase transition curve of our algorithm is noticeably better than that of NNM. Interestingly, it is close to the information-theoretic lower bound for the minimal number of measurements needed for matrix recovery, making it not only state of the art in terms of convergence rate, but also near optimal in terms of the matrices it successfully recovers. Copyright © 2018 the Author(s). Published by PNAS.

  14. Adjustment of Pesticide Concentrations for Temporal Changes in Analytical Recovery, 1992-2006

    USGS Publications Warehouse

    Martin, Jeffrey D.; Stone, Wesley W.; Wydoski, Duane S.; Sandstrom, Mark W.

    2009-01-01

    Recovery is the proportion of a target analyte that is quantified by an analytical method and is a primary indicator of the analytical bias of a measurement. Recovery is measured by analysis of quality-control (QC) water samples that have known amounts of target analytes added ('spiked' QC samples). For pesticides, recovery is the measured amount of pesticide in the spiked QC sample expressed as percentage of the amount spiked, ideally 100 percent. Temporal changes in recovery have the potential to adversely affect time-trend analysis of pesticide concentrations by introducing trends in environmental concentrations that are caused by trends in performance of the analytical method rather than by trends in pesticide use or other environmental conditions. This report examines temporal changes in the recovery of 44 pesticides and 8 pesticide degradates (hereafter referred to as 'pesticides') that were selected for a national analysis of time trends in pesticide concentrations in streams. Water samples were analyzed for these pesticides from 1992 to 2006 by gas chromatography/mass spectrometry. Recovery was measured by analysis of pesticide-spiked QC water samples. Temporal changes in pesticide recovery were investigated by calculating robust, locally weighted scatterplot smooths (lowess smooths) for the time series of pesticide recoveries in 5,132 laboratory reagent spikes; 1,234 stream-water matrix spikes; and 863 groundwater matrix spikes. A 10-percent smoothing window was selected to show broad, 6- to 12-month time scale changes in recovery for most of the 52 pesticides. Temporal patterns in recovery were similar (in phase) for laboratory reagent spikes and for matrix spikes for most pesticides. In-phase temporal changes among spike types support the hypothesis that temporal change in method performance is the primary cause of temporal change in recovery. Although temporal patterns of recovery were in phase for most pesticides, recovery in matrix spikes was greater than recovery in reagent spikes for nearly every pesticide. Models of recovery based on matrix spikes are deemed more appropriate for adjusting concentrations of pesticides measured in groundwater and stream-water samples than models based on laboratory reagent spikes because (1) matrix spikes are expected to more closely match the matrix of environmental water samples than are reagent spikes and (2) method performance is often matrix dependent, as was shown by higher recovery in matrix spikes for most of the pesticides. Models of recovery, based on lowess smooths of matrix spikes, were developed separately for groundwater and stream-water samples. The models of recovery can be used to adjust concentrations of pesticides measured in groundwater or stream-water samples to 100 percent recovery to compensate for temporal changes in the performance (bias) of the analytical method.

  15. Multi-Shot Sensitivity-Encoded Diffusion Data Recovery Using Structured Low-Rank Matrix Completion (MUSSELS)

    PubMed Central

    Mani, Merry; Jacob, Mathews; Kelley, Douglas; Magnotta, Vincent

    2017-01-01

    Purpose To introduce a novel method for the recovery of multi-shot diffusion weighted (MS-DW) images from echo-planar imaging (EPI) acquisitions. Methods Current EPI-based MS-DW reconstruction methods rely on the explicit estimation of the motion-induced phase maps to recover artifact-free images. In the new formulation, the k-space data of the artifact-free DWI is recovered using a structured low-rank matrix completion scheme, which does not require explicit estimation of the phase maps. The structured matrix is obtained as the lifting of the multi-shot data. The smooth phase-modulations between shots manifest as null-space vectors of this matrix, which implies that the structured matrix is low-rank. The missing entries of the structured matrix are filled in using a nuclear-norm minimization algorithm subject to the data-consistency. The formulation enables the natural introduction of smoothness regularization, thus enabling implicit motion-compensated recovery of the MS-DW data. Results Our experiments on in-vivo data show effective removal of artifacts arising from inter-shot motion using the proposed method. The method is shown to achieve better reconstruction than the conventional phase-based methods. Conclusion We demonstrate the utility of the proposed method to effectively recover artifact-free images from Cartesian fully/under-sampled and partial Fourier acquired data without the use of explicit phase estimates. PMID:27550212

  16. Calcium Isotope Analysis with "Peak Cut" Method on Column Chemistry

    NASA Astrophysics Data System (ADS)

    Zhu, H.; Zhang, Z.; Liu, F.; Li, X.

    2017-12-01

    To eliminate isobaric interferences from elemental and molecular isobars (e.g., 40K+, 48Ti+, 88Sr2+, 24Mg16O+, 27Al16O+) on Ca isotopes during mass determination, samples should be purified through ion-exchange column chemistry before analysis. However, large Ca isotopic fractionation has been observed during column chemistry (Russell and Papanastassiou, 1978; Zhu et al., 2016). Therefore, full recovery during column chemistry is greatly needed, otherwise uncertainties would be caused by poor recovery (Zhu et al., 2016). Generally, matrix effects could be enhanced by full recovery, as other elements might overlap with Ca cut during column chemistry. Matrix effects and full recovery are difficult to balance and both need to be considered for high-precision analysis of stable Ca isotopes. Here, we investigate the influence of poor recovery on δ44/40Ca using TIMS with the double spike technique. The δ44/40Ca values of IAPSO seawater, ML3B-G and BHVO-2 in different Ca subcats (e.g., 0-20, 20-40, 40-60, 60-80, 80-100%) with 20% Ca recovery on column chemistry display limited variation after correction by the 42Ca-43Ca double spike technique with the exponential law. Notably, δ44/40Ca of each Ca subcut is quite consistent with δ44/40Ca of Ca cut with full recovery within error. Our results indicate that the 42Ca-43Ca double spike technique can simultaneously correct both of the Ca isotopic fractionation that occurred during column chemistry and thermal ionization mass spectrometry (TIMS) determination properly, because both of the isotopic fractionation occurred during analysis follow the exponential law well. Therefore, we propose the "peak cut" method on Ca column chemistry for samples with complex matrix effects. Briefly, for samples with low Ca contents, we can add the double spike before column chemistry, and only collect the middle of the Ca eluate and abandon the both sides of Ca eluate that might overlap with other elements (e.g., K, Sr). This method would eliminate matrix effects and improve efficiency for the column chemistry.

  17. Statistical evaluation of the influence of soil properties on recoveries and matrix effects during the analysis of pharmaceutical compounds and steroids by quick, easy, cheap, effective, rugged and safe extraction followed by liquid chromatography-tandem mass spectrometry.

    PubMed

    Salvia, Marie-Virginie; Cren-Olivé, Cécile; Vulliet, Emmanuelle

    2013-11-08

    Numerous chemical products are dispersed in our environment. Many of them are recognized as harmful to humans and the ecosystem. Among these harmful substances are antibiotics and steroid hormones. Currently, very few data are available on the presence and fate of these substances in the environment, in particular for solid matrices, mainly due to a lack of analytical methodologies. Indeed, soil is a very complex matrix, and the nature and composition of the soil has a significant impact on the extraction efficiency and the sensitivity of the method. For this reason a statistical approach was performed to study the influence of soil parameters (clay, silt, sand and organic carbon percentages and cation exchange capacity (CEC)) on recoveries and matrix effects of various pharmaceuticals and steroids. Thus, an analysis of covariance (ANCOVA) was performed when several substances were analyzed simultaneously, whereas a Pearson correlation was used to study the compounds individually. To the best of our knowledge, this study is the first time such an experiment was performed. The results showed that clay and organic carbon percentages as well as the CEC have an impact on the recoveries of most of the target substances, the variables being anti-correlated. This result suggests that the compounds are trapped in soils with high levels of clay and organic carbon and a high CEC. For the matrix effects, it was shown that the organic carbon content has a significant effect on steroid hormones and penicillin G matrix effects (positive correlation). Finally, interaction effects (first order) were evaluated. This latter point corresponds to the crossed effects that occur between explanatory variables (soil parameters). Indeed, the value taken by an explanatory variable can have an influence on the effect that another explanatory variable has on a dependent variable. For instance, it was shown that some parameters (silt, sand) have an impact on the effect that clay content has on recoveries. Besides, CEC and silt affect the influence that organic carbon percentage has on matrix effect. This original approach provides a better understanding of the complex interactions that occur in soil and could be useful to understand and predict the performance of an analytical method. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. Background recovery via motion-based robust principal component analysis with matrix factorization

    NASA Astrophysics Data System (ADS)

    Pan, Peng; Wang, Yongli; Zhou, Mingyuan; Sun, Zhipeng; He, Guoping

    2018-03-01

    Background recovery is a key technique in video analysis, but it still suffers from many challenges, such as camouflage, lighting changes, and diverse types of image noise. Robust principal component analysis (RPCA), which aims to recover a low-rank matrix and a sparse matrix, is a general framework for background recovery. The nuclear norm is widely used as a convex surrogate for the rank function in RPCA, which requires computing the singular value decomposition (SVD), a task that is increasingly costly as matrix sizes and ranks increase. However, matrix factorization greatly reduces the dimension of the matrix for which the SVD must be computed. Motion information has been shown to improve low-rank matrix recovery in RPCA, but this method still finds it difficult to handle original video data sets because of its batch-mode formulation and implementation. Hence, in this paper, we propose a motion-assisted RPCA model with matrix factorization (FM-RPCA) for background recovery. Moreover, an efficient linear alternating direction method of multipliers with a matrix factorization (FL-ADM) algorithm is designed for solving the proposed FM-RPCA model. Experimental results illustrate that the method provides stable results and is more efficient than the current state-of-the-art algorithms.

  19. Matrix effects on organic pollutants analysis in marine sediment

    NASA Astrophysics Data System (ADS)

    Azis, M. Y.; Asia, L.; Piram, A.; Buchari, B.; Doumenq, P.; Setiyanto, H.

    2018-05-01

    Interference from the matrix sample can influence of the accurate analytical method. Accelerated Solvent Extraction and their purification methods were tried to separate the organic micropollutants respectively in marine sediment. Those matrix were as organic pollutants evaluation in marine environment. Polychlorinated Biphenyls (PCBs) and Organochlorine pesticides (OCPs) are two examples organic pollutant in environment which are carcinogenic and mutagenic. Marine sediments are important matrices of information regarding the human activities in coastal areas as well as the fate and behavior of organic pollutants, which are persistent in long-term. This research purpose to evaluate the matrice effect and the recovery from marine sediment spiking with several standar solution and deuterium of molecular target from organic pollutants in not polluted sample of sediment. Matrice samples was tested from indicate in unpolluted location. The methods were evaluated with standard calibration curve (linearity < 0.999, LOQ various ranged 0.5-1000 pg.μL-1 and LOD > LOQ). Recovery (YE) relative, Matrice Effect (ME) relative correction with deuteriated standar were evaluated the interference the matrix. Interference effect for OCPs compounds were higher than PCBs in marine sediment.

  20. Interference by the activated sludge matrix on the analysis of soluble microbial products in wastewater.

    PubMed

    Potvin, Christopher M; Zhou, Hongde

    2011-11-01

    The objective of this study was to demonstrate the effects of complex matrix effects caused by chemical materials on the analysis of key soluble microbial products (SMP) including proteins, humics, carbohydrates, and polysaccharides in activated sludge samples. Emphasis was placed on comparison of the commonly used standard curve technique with standard addition (SA), a technique that differs in that the analytical responses are measured for sample solutions spiked with known quantities of analytes. The results showed that using SA provided a great improvement in compensating for SMP recovery and thus improving measurement accuracy by correcting for matrix effects. Analyte recovery was found to be highly dependent on sample dilution, and changed due to extraction techniques, storage conditions and sample composition. Storage of sample extracts by freezing changed SMP concentrations dramatically, as did storage at 4°C for as little as 1d. Copyright © 2011 Elsevier Ltd. All rights reserved.

  1. VOLATILE ORGANIC COMPOUND DETERMINATIONS USING SURROGATE-BASED CORRECTION FOR METHOD AND MATRIX EFFECTS

    EPA Science Inventory

    The principal properties related to analyte recovery in a vacuum distillate are boiling point and relative volatility. The basis for selecting compounds to measure the relationship between these properties and recovery for a vacuum distillation is presented. Surrogates are incorp...

  2. Effect of Binding Components in Complex Sample Matrices on Recovery in Direct Immersion Solid-Phase Microextraction: Friends or Foe?

    PubMed

    Alam, Md Nazmul; Pawliszyn, Janusz

    2018-02-20

    The development of matrix compatible coatings for solid-phase microextraction (SPME) has enabled direct extraction of analytes from complex sample matrices. The direct immersion (DI) mode of SPME when utilized in conjunction with such extraction phases facilitates extraction of a wide range of analytes from complex matrices without the incurrence of fouling or coating saturation. In this work, mathematical models and computational simulations were employed to investigate the effect of binding components present in complex samples on the recovery of small molecules varying in logP for extractions carried out using the direct immersion approach. The presented findings corroborate that the studied approach indeed enables the extraction of both polar and nonpolar analytes from complex matrices, provided a suitable sorbent is employed. Further results indicated that, in certain cases, the kinetics of extraction of a given analyte in its free form might be dependent on the desorption kinetics of their bound form from matrix components, which might lower total recoveries of analytes with high affinity for the matrix. However, the binding of analytes to matrix components also enables SPME to extract a balanced quantity of different logP analytes, facilitated by multiphase equilibria, with a single extraction device.

  3. The Mechanical Properties and Modeling of Creep Behavior of UHMWPE/Nano-HA Composites

    NASA Astrophysics Data System (ADS)

    Li, Fan; Gao, Lilan; Gao, Hong; Cui, Yun

    2017-09-01

    Composites with different levels of hydroxyapatite (HA) content and ultra-high molecular weight polyethylene (UHMWPE) were prepared in this work. Mechanical properties of the composites were examined here, and to evaluate the effect of HA particles on the time-dependent behavior of the pure matrix, the creep and recovery performance of composites at various stress levels were also researched. As expected, the addition of HA influenced the time-dependent response of the UHMWPE and the effect had a strong dependence on the HA content. The creep and recovery strain of the composites significantly decreased with increasing HA content, and tensile properties were also impaired, which was due to the concentration of HA fillers. The mechanism and effect of HA dispersed into the UHMWPE matrix were examined by scanning electron microscopy. Additionally, since variations in the adjusted parameters revealed the impact of HA on the creep behavior of the UHMWPE matrix, Findley's model was employed. The results indicated that the analytical model was accurate for the prediction of creep of the pure matrix and its composites.

  4. Reply to “Ranking filter methods for concentrating pathogens in lake water”

    USGS Publications Warehouse

    Bushon, Rebecca N.; Francy, Donna S.; Gallardo, Vicente J.; Lindquist, H.D. Alan; Villegas, Eric N.; Ware, Michael W.

    2013-01-01

    Accurately comparing filtration methods is indeed difficult. Our method (1) and the method described by Borchardt et al. for determining recoveries are both acceptable approaches; however, each is designed to achieve a different research goal. Our study was designed to compare recoveries of multiple microorganisms in surface-water samples. Because, in practice, water-matrix effects come into play throughout filtration, concentration, and detection processes, we felt it important to incorporate those effects into the recovery results.

  5. EVALUATION OF SPIKING PROCEDURES FOR RECOVERY OF CRYPTOSPORIDIUM IN STREAM WATERS USING USEPA METHOD 1623

    EPA Science Inventory

    U.S. Environmental Protection Agency Method 1623 is widely used to monitor source waters and drinking water supplies for Cryptosporidium oocysts. Analyzing matrix spikes is an important component of Method 1623. Matrix spikes are used to determine the effect of the environmental...

  6. Matrix effect and optimization of LC-MSn determination of trachylobane-360 in mice blood.

    PubMed

    Pita, João Carlos Lima Rodrigues; Gomes, Isis Fernandes; Dos Santos, Socrates Golzio; Tavares, Josean Fechine; da Silva, Marcelo Sobral; Diniz, Margareth de Fátima Formiga Melo; Sobral, Marianna Vieira

    2014-11-01

    Xylopia langsdorffiana A. St.-Hil. & Tul. (Annonaceae) is popularly known as "pimenteira-da-terra". Various constituents have been isolated from this species, including diterpenes, such as 8(17), 12E, 14-labdatrien-18-oic acid, ent-atisan-7α, 16α-diol (xylodiol), ent-7α-hydroxytrachyloban-18-oic acid (trachylobane-318) and ent-7α-acetoxytrachyloban-18-oic acid, a crystalline solid with a molecular weight of 360 and molecular formula of C22H32O4 (trachylobane-360). When administered intraperitoneally to mice, trachylobane-360 (T-360) significantly inhibits growth of the solid tumor sarcoma 180 transplanted in mice, without causing alterations in biochemical, hematological and histopathological parameters that are frequently associated with the clinical use of antineoplastic. Furthermore, this diterpene blocks voltage-dependent calcium channels (Cav), showing spasmolytic activity. The present study shows that variables such as extraction solvent (methanol, acetonitrile and chloroform), centrifugation force (1000, 7000 and 14,000×g), and centrifugation time (5, 15 and 25min), are important in the liquid-liquid extraction of T-360 from male Swiss mice blood in HPLC-MSn studies. The study confirms matrix influence on recovery and detection of T-360. The recovery for T-360 was 37.02% using chloroform as better extractor solvent, while centrifuged at 14,000×g for 15min demonstrated the importance of the parameters chosen for the extraction/recovery process of analyte. The effect of mice blood matrix for T-360 was -51.23%. This method was optimized by repeating the extraction procedure and acidification of samples. These conditions were essential in increasing recovery (49.47%) by decreasing the matrix effect (-37.60%). The efficiency of the process, after optimization with two extractions and acidification, increased by 14.19% when compared to the initial method, from 18.05% to 32.24%. According to Marchi et al. (2010), the matrix effect does not necessarily need to be reduced or eliminated, but it does need to be identified and quantified. Therefore, these findings are essential for the subsequent evaluation of the pharmacokinetic parameters of this promising natural product. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. SURFACTANT ENHANCED RECOVERY OF TETRACHLOROETHYLENE FROM A POROUS MEDIUM CONTAINING LOW PERMEABILITY LENSES. 1. EXPERIMENTAL STUDIES. (R825409)

    EPA Science Inventory

    Abstract

    A matrix of batch, column and two-dimensional (2-D) box experiments was conducted to investigate the coupled effects of rate-limited solubilization and layering on the entrapment and subsequent recovery of a representative dense NAPL, tetrachloroethylene (PCE)...

  8. Formulation of immunoassay calibrators in pasteurized albumin can significantly enhance their durability.

    PubMed

    Warren, David J; Nordlund, Marianne S; Paus, Elisabeth

    2010-02-28

    Calibrator matrix can have significant effects on the commutability of assay standards and on the maintenance of their integrity. We have observed marked instability in progastrin-releasing peptide (proGRP) assay standards traceable to the bovine serum albumin (BSA) used in matrix formulation. Attempts were made to improve calibrator stability using different albumin pretreatments. Observed analyte recoveries in calibrators prepared with untreated BSA were consistently less than 45% after 1 week of storage at 4 degrees C. Pre-treating the BSA by chromatography on immobilized heparin or benzamidine failed to improve calibrator durability with day 7 recoveries of less than 55%. In marked contrast, calibrators formulated with albumin pasteurized at pH 3.0 displayed remarkable stability. Recoveries of >97% were observed after 4 weeks of storage at either 4 degrees C or room temperature. Even calibrators incubated for 4 weeks at 37 degrees C gave recoveries between 91-106%. This improvement was not seen with BSA pasteurized at neutral pH. Albumin pretreatment is straightforward, easily scalable and dramatically improves calibrator stability. Matrix formulated with acid-pasteurized BSA may prove more generally useful when assays are plagued by poor calibrator durability. 2009 Elsevier B.V. All rights reserved.

  9. Matrix solid-phase dispersion extraction of sulfonamides from blood.

    PubMed

    Zhang, Yupu; Xu, Xu; Liu, He; Zhai, Yujuan; Sun, Ye; Sun, Shuo; Zhang, Hanqi; Yu, Aimin; Wang, Yinghua

    2012-02-01

    Matrix solid-phase dispersion extraction was applied to the extraction of sulfadiazine, sulfamerazine, and sulfamethazine from human and animal bloods. The separation and determination of the analytes were carried out by high-performance liquid chromatography. The effects of the types of the dispersion adsorbents and elution solvents were investigated, and the highest recovery was obtained when diatomaceous earth was used as the dispersion adsorbent, while acetone was used as the elution solvent. Under the optimal conditions, the linear range for determining the sulfonamides in blood samples was 0.020-10.0 µg/mL, and the average recoveries of the three sulfonamides were higher than 87.5%.

  10. Preferential Enhancement of Sensory and Motor Axon Regeneration by Combining Extracellular Matrix Components with Neurotrophic Factors

    PubMed Central

    Santos, Daniel; González-Pérez, Francisco; Giudetti, Guido; Micera, Silvestro; Udina, Esther; Del Valle, Jaume; Navarro, Xavier

    2016-01-01

    After peripheral nerve injury, motor and sensory axons are able to regenerate but inaccuracy of target reinnervation leads to poor functional recovery. Extracellular matrix (ECM) components and neurotrophic factors (NTFs) exert their effect on different neuronal populations creating a suitable environment to promote axonal growth. Here, we assessed in vitro and in vivo the selective effects of combining different ECM components with NTFs on motor and sensory axons regeneration and target reinnervation. Organotypic cultures with collagen, laminin and nerve growth factor (NGF)/neurotrophin-3 (NT3) or collagen, fibronectin and brain-derived neurotrophic factor (BDNF) selectively enhanced sensory neurite outgrowth of DRG neurons and motor neurite outgrowth from spinal cord slices respectively. For in vivo studies, the rat sciatic nerve was transected and repaired with a silicone tube filled with a collagen and laminin matrix with NGF/NT3 encapsulated in poly(lactic-co-glycolic acid) (PLGA) microspheres (MP) (LM + MP.NGF/NT3), or a collagen and fibronectin matrix with BDNF in PLGA MPs (FN + MP.BDNF). Retrograde labeling and functional tests showed that LM + MP.NGF/NT3 increased the number of regenerated sensory neurons and improved sensory functional recovery, whereas FN + MP.BDNF preferentially increased regenerated motoneurons and enhanced motor functional recovery. Therefore, combination of ECM molecules with NTFs may be a good approach to selectively enhance motor and sensory axons regeneration and promote appropriate target reinnervation. PMID:28036084

  11. Validation of QuEChERS method for the determination of some pesticide residues in two apple varieties.

    PubMed

    Tiryaki, Osman

    2016-10-02

    This study was undertaken to validate the "quick, easy, cheap, effective, rugged and safe" (QuEChERS) method using Golden Delicious and Starking Delicious apple matrices spiked at 0.1 maximum residue limit (MRL), 1.0 MRL and 10 MRL levels of the four pesticides (chlorpyrifos, dimethoate, indoxacarb and imidacloprid). For the extraction and cleanup, original QuEChERS method was followed, then the samples were subjected to liquid chromatography-triple quadrupole mass spectrometry (LC-MS/MS) for chromatographic analyses. According to t test, matrix effect was not significant for chlorpyrifos in both sample matrices, but it was significant for dimethoate, indoxacarb and imidacloprid in both sample matrices. Thus, matrix-matched calibration (MC) was used to compensate matrix effect and quantifications were carried out by using MC. The overall recovery of the method was 90.15% with a relative standard deviation of 13.27% (n = 330). Estimated method detection limit of analytes blew the MRLs. Some other parameters of the method validation, such as recovery, precision, accuracy and linearity were found to be within the required ranges.

  12. Ranking filter methods for concentrating pathogens in lake water

    USDA-ARS?s Scientific Manuscript database

    Accurately comparing filtration methods for concentrating waterborne pathogens is difficult because of two important water matrix effects on recovery measurements, the effect on PCR quantification and the effect on filter performance. Regarding the first effect, we show how to create a control water...

  13. High-dimensional statistical inference: From vector to matrix

    NASA Astrophysics Data System (ADS)

    Zhang, Anru

    Statistical inference for sparse signals or low-rank matrices in high-dimensional settings is of significant interest in a range of contemporary applications. It has attracted significant recent attention in many fields including statistics, applied mathematics and electrical engineering. In this thesis, we consider several problems in including sparse signal recovery (compressed sensing under restricted isometry) and low-rank matrix recovery (matrix recovery via rank-one projections and structured matrix completion). The first part of the thesis discusses compressed sensing and affine rank minimization in both noiseless and noisy cases and establishes sharp restricted isometry conditions for sparse signal and low-rank matrix recovery. The analysis relies on a key technical tool which represents points in a polytope by convex combinations of sparse vectors. The technique is elementary while leads to sharp results. It is shown that, in compressed sensing, delta kA < 1/3, deltak A+ thetak,kA < 1, or deltatkA < √( t - 1)/t for any given constant t ≥ 4/3 guarantee the exact recovery of all k sparse signals in the noiseless case through the constrained ℓ1 minimization, and similarly in affine rank minimization delta rM < 1/3, deltar M + thetar, rM < 1, or deltatrM< √( t - 1)/t ensure the exact reconstruction of all matrices with rank at most r in the noiseless case via the constrained nuclear norm minimization. Moreover, for any epsilon > 0, delta kA < 1/3 + epsilon, deltak A + thetak,kA < 1 + epsilon, or deltatkA< √(t - 1) / t + epsilon are not sufficient to guarantee the exact recovery of all k-sparse signals for large k. Similar result also holds for matrix recovery. In addition, the conditions delta kA<1/3, deltak A+ thetak,kA<1, delta tkA < √(t - 1)/t and deltarM<1/3, delta rM+ thetar,rM<1, delta trM< √(t - 1)/ t are also shown to be sufficient respectively for stable recovery of approximately sparse signals and low-rank matrices in the noisy case. For the second part of the thesis, we introduce a rank-one projection model for low-rank matrix recovery and propose a constrained nuclear norm minimization method for stable recovery of low-rank matrices in the noisy case. The procedure is adaptive to the rank and robust against small perturbations. Both upper and lower bounds for the estimation accuracy under the Frobenius norm loss are obtained. The proposed estimator is shown to be rate-optimal under certain conditions. The estimator is easy to implement via convex programming and performs well numerically. The techniques and main results developed in the chapter also have implications to other related statistical problems. An application to estimation of spiked covariance matrices from one-dimensional random projections is considered. The results demonstrate that it is still possible to accurately estimate the covariance matrix of a high-dimensional distribution based only on one-dimensional projections. For the third part of the thesis, we consider another setting of low-rank matrix completion. Current literature on matrix completion focuses primarily on independent sampling models under which the individual observed entries are sampled independently. Motivated by applications in genomic data integration, we propose a new framework of structured matrix completion (SMC) to treat structured missingness by design. Specifically, our proposed method aims at efficient matrix recovery when a subset of the rows and columns of an approximately low-rank matrix are observed. We provide theoretical justification for the proposed SMC method and derive lower bound for the estimation errors, which together establish the optimal rate of recovery over certain classes of approximately low-rank matrices. Simulation studies show that the method performs well in finite sample under a variety of configurations. The method is applied to integrate several ovarian cancer genomic studies with different extent of genomic measurements, which enables us to construct more accurate prediction rules for ovarian cancer survival.

  14. Scaling of counter-current imbibition recovery curves using artificial neural networks

    NASA Astrophysics Data System (ADS)

    Jafari, Iman; Masihi, Mohsen; Nasiri Zarandi, Masoud

    2018-06-01

    Scaling imbibition curves are of great importance in the characterization and simulation of oil production from naturally fractured reservoirs. Different parameters such as matrix porosity and permeability, oil and water viscosities, matrix dimensions, and oil/water interfacial tensions have an effective on the imbibition process. Studies on the scaling imbibition curves along with the consideration of different assumptions have resulted in various scaling equations. In this work, using an artificial neural network (ANN) method, a novel technique is presented for scaling imbibition recovery curves, which can be used for scaling the experimental and field-scale imbibition cases. The imbibition recovery curves for training and testing the neural network were gathered through the simulation of different scenarios using a commercial reservoir simulator. In this ANN-based method, six parameters were assumed to have an effect on the imbibition process and were considered as the inputs for training the network. Using the ‘Bayesian regularization’ training algorithm, the network was trained and tested. Training and testing phases showed superior results in comparison with the other scaling methods. It is concluded that using the new technique is useful for scaling imbibition recovery curves, especially for complex cases, for which the common scaling methods are not designed.

  15. Evaluation of zirconium dioxide-based sorbents to decrease the matrix effect in avocado and almond multiresidue pesticide analysis followed by gas chromatography tandem mass spectrometry.

    PubMed

    Lozano, Ana; Rajski, Łukasz; Uclés, Samanta; Belmonte-Valles, Noelia; Mezcua, Milagros; Fernández-Alba, Amadeo R

    2014-01-01

    Two sorbents containing ZrO₂ (Z-Sep and Z-Sep+) were tested as a d-SPE clean-up in combination with the QuEChERS and ethyl acetate multiresidue method in the pesticide residues extraction in avocado. All extracts were analysed using gas chromatography coupled with a triple quadrupole mass spectrometer working in multi-reaction monitoring mode. GC QToF was used to compare the amount of matrix compounds present in the final extracts, prepared according to different protocols. The highest number of pesticides with acceptable recoveries and the lowest amount of coextracted matrix compounds were provided by QuEChERS with Z-Sep. Subsequently, this method was fully validated in avocado and almonds. Validation studies were carried out according to DG Sanco guidelines including: the evaluation of recoveries at two levels (10 and 50 μg/kg), limit of quantitation, linearity, matrix effects, as well as interday and intraday precision. In avocado, 166 pesticides were fully validated compared to 119 in almonds. The method was operated satisfactorily in routine analysis and was applied to real samples. © 2013 Published by Elsevier B.V.

  16. Effects of processing on the recovery of food allergens from a model dark chocolate matrix.

    PubMed

    Khuda, Sefat E; Jackson, Lauren S; Fu, Tong-Jen; Williams, Kristina M

    2015-02-01

    To alleviate the risk to allergic consumers, it is crucial to improve factors affecting the detection of food allergens in processed chocolate products. This study evaluated processing effects on (1) recovery of peanut, egg, and milk allergens using five different extraction buffers, and (2) identification of specific allergenic proteins from extracts of incurred chocolate using allergen-specific antibodies and human allergic sera. Immunochemical staining with polyclonal antibodies showed that the addition of detergent or reducing agent improved extraction efficiency of peanut proteins, but not of egg and milk proteins. Tempering decreased antibody binding regardless of extractant. Detection of IgE-reactive peanut, egg, and milk allergens was differentially affected by tempering and extractant. Detection problems associated with matrix and processing effects may be overcome by the choice of extraction buffer and detecting antibody. Published by Elsevier Ltd.

  17. Epicardial infarct repair with bioinductive extracellular matrix promotes vasculogenesis and myocardial recovery.

    PubMed

    Mewhort, Holly E M; Turnbull, Jeannine D; Satriano, Alessandro; Chow, Kelvin; Flewitt, Jacqueline A; Andrei, Adin-Cristian; Guzzardi, David G; Svystonyuk, Daniyil A; White, James A; Fedak, Paul W M

    2016-05-01

    Infarcted myocardium can remodel after successful reperfusion, resulting in left ventricular dilation and heart failure. Epicardial infarct repair (EIR) using a bioinductive extracellular matrix (ECM) biomaterial is a novel surgical approach to promote endogenous myocardial repair and functional recovery after myocardial infarction. Using a pre-clinical porcine model of coronary ischemia-reperfusion, we assessed the effects of EIR on regional functional recovery, safety, and possible mechanisms of benefit. An ECM biomaterial (CorMatrix ECM) was applied to the epicardium after 75 minutes of coronary ischemia in a porcine model. Following ischemia-reperfusion injury, animals were randomly assigned in 2:1 fashion to EIR (n = 8) or sham treatment (n = 4). Serial cardiac magnetic resonance imaging was performed on normal (n = 4) and study animals at baseline (1 week) and 6 weeks after treatment. Myocardial function and tissue characteristics were assessed. Functional myocardial recovery was significantly increased by EIR compared with sham treatment (change in regional myocardial contraction at 6 weeks, 28.6 ± 14.0% vs 4.2 ± 13.5% wall thickening, p < 0.05). Animals receiving EIR had reduced adhesions compared with animals receiving sham treatment (1.44 ± 0.51 vs 3.08 ± 0.89, p < 0.05). Myocardial fibrosis was not increased, and EIR did not cause myocardial constriction, as left ventricular compliance by passive pressure distention at matched volumes was similar between groups (13.9 ± 4.0 mm Hg in EIR group vs 16.0 ± 5.2 mm Hg in sham group, p = 0.61). Animals receiving EIR showed evidence of vasculogenesis in the region of functional recovery. In addition to the beneficial effects of successful reperfusion, EIR using a bioinductive ECM enhances myocardial repair and functional recovery. Clinical translation of EIR early after myocardial infarction as an adjunct to surgical revascularization may be warranted in the future. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  18. Multi-class multi-residue analysis of veterinary drugs in meat using enhanced matrix removal lipid cleanup and liquid chromatography-tandem mass spectrometry.

    PubMed

    Zhao, Limian; Lucas, Derick; Long, David; Richter, Bruce; Stevens, Joan

    2018-05-11

    This study presents the development and validation of a quantitation method for the analysis of multi-class, multi-residue veterinary drugs using lipid removal cleanup cartridges, enhanced matrix removal lipid (EMR-Lipid), for different meat matrices by liquid chromatography tandem mass spectrometry detection. Meat samples were extracted using a two-step solid-liquid extraction followed by pass-through sample cleanup. The method was optimized based on the buffer and solvent composition, solvent additive additions, and EMR-Lipid cartridge cleanup. The developed method was then validated in five meat matrices, porcine muscle, bovine muscle, bovine liver, bovine kidney and chicken liver to evaluate the method performance characteristics, such as absolute recoveries and precision at three spiking levels, calibration curve linearity, limit of quantitation (LOQ) and matrix effect. The results showed that >90% of veterinary drug analytes achieved satisfactory recovery results of 60-120%. Over 97% analytes achieved excellent reproducibility results (relative standard deviation (RSD) < 20%), and the LOQs were 1-5 μg/kg in the evaluated meat matrices. The matrix co-extractive removal efficiency by weight provided by EMR-lipid cartridge cleanup was 42-58% in samples. The post column infusion study showed that the matrix ion suppression was reduced for samples with the EMR-Lipid cartridge cleanup. The reduced matrix ion suppression effect was also confirmed with <15% frequency of compounds with significant quantitative ion suppression (>30%) for all tested veterinary drugs in all of meat matrices. The results showed that the two-step solid-liquid extraction provides efficient extraction for the entire spectrum of veterinary drugs, including the difficult classes such as tetracyclines, beta-lactams etc. EMR-Lipid cartridges after extraction provided efficient sample cleanup with easy streamlined protocol and minimal impacts on analytes recovery, improving method reliability and consistency. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Assessment of a Three-Dimensional Line-of-Response Probability Density Function System Matrix for PET

    PubMed Central

    Yao, Rutao; Ramachandra, Ranjith M.; Mahajan, Neeraj; Rathod, Vinay; Gunasekar, Noel; Panse, Ashish; Ma, Tianyu; Jian, Yiqiang; Yan, Jianhua; Carson, Richard E.

    2012-01-01

    To achieve optimal PET image reconstruction through better system modeling, we developed a system matrix that is based on the probability density function for each line of response (LOR-PDF). The LOR-PDFs are grouped by LOR-to-detector incident angles to form a highly compact system matrix. The system matrix was implemented in the MOLAR list mode reconstruction algorithm for a small animal PET scanner. The impact of LOR-PDF on reconstructed image quality was assessed qualitatively as well as quantitatively in terms of contrast recovery coefficient (CRC) and coefficient of variance (COV), and its performance was compared with a fixed Gaussian (iso-Gaussian) line spread function. The LOR-PDFs of 3 coincidence signal emitting sources, 1) ideal positron emitter that emits perfect back-to-back γ rays (γγ) in air; 2) fluorine-18 (18F) nuclide in water; and 3) oxygen-15 (15O) nuclide in water, were derived, and assessed with simulated and experimental phantom data. The derived LOR-PDFs showed anisotropic and asymmetric characteristics dependent on LOR-detector angle, coincidence emitting source, and the medium, consistent with common PET physical principles. The comparison of the iso-Gaussian function and LOR-PDF showed that: 1) without positron range and acolinearity effects, the LOR-PDF achieved better or similar trade-offs of contrast recovery and noise for objects of 4-mm radius or larger, and this advantage extended to smaller objects (e.g. 2-mm radius sphere, 0.6-mm radius hot-rods) at higher iteration numbers; and 2) with positron range and acolinearity effects, the iso-Gaussian achieved similar or better resolution recovery depending on the significance of positron range effect. We conclude that the 3-D LOR-PDF approach is an effective method to generate an accurate and compact system matrix. However, when used directly in expectation-maximization based list-mode iterative reconstruction algorithms such as MOLAR, its superiority is not clear. For this application, using an iso-Gaussian function in MOLAR is a simple but effective technique for PET reconstruction. PMID:23032702

  20. Fibronectin EDA forms the chronic fibrotic scar after contusive spinal cord injury.

    PubMed

    Cooper, John G; Jeong, Su Ji; McGuire, Tammy L; Sharma, Sripadh; Wang, Wenxia; Bhattacharyya, Swati; Varga, John; Kessler, John A

    2018-04-27

    Gliosis and fibrosis after spinal cord injury (SCI) lead to formation of a scar that is an impediment to axonal regeneration. Fibrotic scarring is characterized by the accumulation of fibronectin, collagen, and fibroblasts at the lesion site. The mechanisms regulating fibrotic scarring after SCI and its effects on axonal elongation and functional recovery are not well understood. In this study, we examined the effects of eliminating an isoform of fibronectin containing the Extra Domain A domain (FnEDA) on both fibrosis and on functional recovery after contusion SCI using male and female FnEDA-null mice. Eliminating FnEDA did not reduce the acute fibrotic response but markedly diminished chronic fibrotic scarring after SCI. Glial scarring was unchanged after SCI in FnEDA-null mice. We found that FnEDA was important for the long-term stability of the assembled fibronectin matrix during both the subacute and chronic phases of SCI. Motor functional recovery was significantly improved, and there were increased numbers of axons in the lesion site compared to wildtype mice, suggesting that the chronic fibrotic response is detrimental to recovery. Our data provide insight into the mechanisms of fibrosis after SCI and suggest that disruption of fibronectin matrix stability by targeting FnEDA represents a potential therapeutic strategy for promoting recovery after SCI. Copyright © 2018 Elsevier Inc. All rights reserved.

  1. Extension of the QuEChERS method for pesticide residues in cereals to flaxseeds, peanuts, and doughs.

    PubMed

    Koesukwiwat, Urairat; Lehotay, Steven J; Mastovska, Katerina; Dorweiler, Kelly J; Leepipatpiboon, Natchanun

    2010-05-26

    A simple method was evaluated for the determination of pesticide residues in flaxseeds, doughs, and peanuts using gas chromatography-time-of-flight mass spectrometry (GC-TOF) for analysis. A modified QuEChERS (quick, easy, cheap, effective, rugged, and safe) method, which was previously optimized for cereal grain samples, was evaluated in these fatty matrices. This extraction method involves first mixing the sample with 1:1 water/acetonitrile for an hour to swell the matrix and permit the salt-out liquid-liquid partitioning step using anhydrous MgSO(4) and NaCl. After shaking and centrifugation, cleanup is done by dispersive solid-phase extraction (d-SPE) using 150 mg of anhydrous MgSO(4), 150 mg of PSA, and 50 mg of C-18 per milliliter of extract. This method gave efficient separation of pesticides from fat and removal of coextracted substances better than gel permeation chromatography or use of a freeze-out step, which involved excessive use of solvent and/or time. The optimized analytical conditions were evaluated in terms of recoveries, reproducibilities, limits of detection, and matrix effects for 34 representative pesticides using different types of flaxseeds, peanuts, and doughs. Use of matrix-matched standards provided acceptable results for most pesticides with overall average recoveries between 70 and 120% and consistent RSDs <20% for semipolar pesticides and <26% for lipophilic pesticides. The recoveries of these latter types of pesticides depended on the fat content in the matrices and partitioning factor between the lipids and acetonitrile. We believe that the consistency of the pesticide recoveries for different samples in multiple experiments and the physicochemical partitioning explanation for <70% recoveries of lipophilic pesticides justify compensation of results for the empirically determined recovery values. In any case, this method still meets 10 ng/g detection limit needs for lipophilic pesticides and may be used for qualitative screening applications, in which any identified pesticides can be quantified and confirmed by a more intensive method that achieves >70% recoveries for lipophilic pesticides.

  2. Measurement and Visualization of Tight Rock Exposed to CO2 Using NMR Relaxometry and MRI

    PubMed Central

    Wang, Haitao; Lun, Zengmin; Lv, Chengyuan; Lang, Dongjiang; Ji, Bingyu; Luo, Ming; Pan, Weiyi; Wang, Rui; Gong, Kai

    2017-01-01

    Understanding mechanisms of oil mobilization of tight matrix during CO2 injection is crucial for CO2 enhanced oil recovery (EOR) and sequestration engineering design. In this study exposure behavior between CO2 and tight rock of the Ordos Basin has been studied experimentally by using nuclear magnetic resonance transverse relaxation time (NMR T2) spectrum and magnetic resonance imaging (MRI) under the reservoir pressure and temperature. Quantitative analysis of recovery at the pore scale and visualization of oil mobilization are achieved. Effects of CO2 injection, exposure times and pressure on recovery performance have been investigated. The experimental results indicate that oil in all pores can be gradually mobilized to the surface of rock by CO2 injection. Oil mobilization in tight rock is time-consuming while oil on the surface of tight rock can be mobilized easily. CO2 injection can effectively mobilize oil in all pores of tight rock, especially big size pores. This understanding of process of matrix exposed to CO2 could support the CO2 EOR in tight reservoirs. PMID:28281697

  3. Low-rank matrix decomposition and spatio-temporal sparse recovery for STAP radar

    DOE PAGES

    Sen, Satyabrata

    2015-08-04

    We develop space-time adaptive processing (STAP) methods by leveraging the advantages of sparse signal processing techniques in order to detect a slowly-moving target. We observe that the inherent sparse characteristics of a STAP problem can be formulated as the low-rankness of clutter covariance matrix when compared to the total adaptive degrees-of-freedom, and also as the sparse interference spectrum on the spatio-temporal domain. By exploiting these sparse properties, we propose two approaches for estimating the interference covariance matrix. In the first approach, we consider a constrained matrix rank minimization problem (RMP) to decompose the sample covariance matrix into a low-rank positivemore » semidefinite and a diagonal matrix. The solution of RMP is obtained by applying the trace minimization technique and the singular value decomposition with matrix shrinkage operator. Our second approach deals with the atomic norm minimization problem to recover the clutter response-vector that has a sparse support on the spatio-temporal plane. We use convex relaxation based standard sparse-recovery techniques to find the solutions. With extensive numerical examples, we demonstrate the performances of proposed STAP approaches with respect to both the ideal and practical scenarios, involving Doppler-ambiguous clutter ridges, spatial and temporal decorrelation effects. As a result, the low-rank matrix decomposition based solution requires secondary measurements as many as twice the clutter rank to attain a near-ideal STAP performance; whereas the spatio-temporal sparsity based approach needs a considerably small number of secondary data.« less

  4. Comparison of QuEChERS sample preparation methods for the analysis of pesticide residues in canned and fresh peach.

    PubMed

    Costa, Fabiane Pinho; Caldas, Sergiane Souza; Primel, Ednei Gilberto

    2014-12-15

    Original, citrate and acetate QuEChERS methods were studied in order to evaluate the extraction efficiency and the matrix effect in the extraction of pesticides from canned peach samples. Determinations were performed by gas chromatography coupled to mass spectrometry (GC-MS). The proposed method with extraction using the original QuEChERS method and determination by GC-MS was validated. LOQs ranged between 1 and 10 μg kg(-1) and all analytical curves showed r values higher than 0.99. Recovery values varied from 69% to 125% with RSDs less than 20%. The matrix effect was evaluated and most compounds showed signal enrichment. Robustness was demonstrated using fresh peaches, which provided recovery values within acceptable limits. The applicability of the method was verified and residues of tebuconazole and dimethoate were found in the samples. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Compensation for matrix effects in the gas chromatography-mass spectrometry analysis of 186 pesticides in tea matrices using analyte protectants.

    PubMed

    Li, Yan; Chen, Xi; Fan, Chunlin; Pang, Guofang

    2012-11-30

    A gas chromatography-mass spectrometry (GC-MS) analytical method was developed for simultaneously determining 186 pesticides in tea matrices using analyte protectants to counteract the matrix-induced effect. The matrix effects were evaluated for green, oolong and black tea, representing unfermented, partially fermented and completely fermented teas respectively and depending on the type of tea, 72%, 94% and 94% of the pesticides presented strong response enhancement effect. Several analyte protectants as well as certain combinations of these protectants were evaluated to check their compensation effects. A mixture of triglycerol and d-ribonic acid-γ-lactone (both at 2mg/mL in the injected samples) was found to be the most effective in improving the chromatographic behavior of the 186 pesticides. More than 96% of the 186 pesticides achieved recoveries within the range of 70-120% when using the selected mixture of analyte protectants. The simple addition of analyte protectants offers a more convenient solution to overcome matrix effects, results in less active sites compared to matrix-matched standardization and can be an effective approach to compensate for matrix effects in the GC-MS analysis of pesticide residues. Copyright © 2012 Elsevier B.V. All rights reserved.

  6. Acetonitrile extraction and dual-layer solid phase extraction clean-up for pesticide residue analysis in propolis.

    PubMed

    Oellig, Claudia

    2016-05-06

    Propolis is a very complex mixture of substances that is produced by honey bees and is known to be a rather challenging matrix for residue analysis. Besides resins, flavonoids and phenols, high amount of wax is co-extracted resulting in immense matrix effects. Therefore a suitable clean-up is crucial and indispensable. In this study, a reliable solid phase extraction (SPE) clean-up was developed for pesticide residue analysis in propolis. The clean-up success was quickly and easily monitored by high-performance thin-layer chromatography with different detection possibilities. The final method consists of the extraction of propolis with acetonitrile according to the QuEChERS method followed by an effective extract purification on dual-layer SPE cartridges with spherical hydrophobic polystyrene-divinylbenzene resin/primary secondary amine as sorbent and a mixture of toluene/acetone (95:5, v/v) for elution. Besides fat-soluble components like waxes, flavonoids, and terpenoids, more polar compounds like organic acids, fatty acids, sugars and anthocyanins were also removed to large extent. Method performance was assessed by recovery experiments at spiking levels of 0.5 and 1mg/kg (n=5) for fourteen pesticides that are relevant for propolis. Mean recoveries determined by HPLC-MS against solvent standards were between 40 and 101%, while calculation against matrix-matched standards provided recoveries of 79-104%. Precision of recovery, assessed by relative standard deviations, were below 9%. Thus, the developed dual-layer SPE clean-up enables the reliable pesticide residue analysis in propolis and provides a suitable alternative to time-consuming clean-up procedures proposed in literature. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Method for the removal and recovery of mercury

    DOEpatents

    Easterly, Clay E.; Vass, Arpad A.; Tyndall, Richard L.

    1997-01-01

    The present invention is an enhanced method for the removal and recovery of mercury from mercury-contaminated matrices. The method involves contacting a mercury-contaminated matrix with an aqueous dispersant solution derived from specific intra-amoebic isolates to release the mercury from the mercury-contaminated matrix and emulsify the mercury; then, contacting the matrix with an amalgamating metal from a metal source to amalgamate the mercury to the amalgamating metal; removing the metallic source from the mercury-contaminated matrix; and heating the metallic source to vaporize the mercury in a closed system to capture the mercury vapors.

  8. Method for the removal and recovery of mercury

    DOEpatents

    Easterly, C.E.; Vass, A.A.; Tyndall, R.L.

    1997-01-28

    The present invention is an enhanced method for the removal and recovery of mercury from mercury-contaminated matrices. The method involves contacting a mercury-contaminated matrix with an aqueous dispersant solution derived from specific intra-amoebic isolates to release the mercury from the mercury-contaminated matrix and emulsify the mercury; then, contacting the matrix with an amalgamating metal from a metal source to amalgamate the mercury to the amalgamating metal; removing the metallic source from the mercury-contaminated matrix; and heating the metallic source to vaporize the mercury in a closed system to capture the mercury vapors.

  9. Ionization Suppression and Recovery in Direct Biofluid Analysis Using Paper Spray Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Vega, Carolina; Spence, Corina; Zhang, Chengsen; Bills, Brandon J.; Manicke, Nicholas E.

    2016-04-01

    Paper spray mass spectrometry is a method for the direct analysis of biofluid samples in which extraction of analytes from dried biofluid spots and electrospray ionization occur from the paper on which the dried sample is stored. We examined matrix effects in the analysis of small molecule drugs from urine, plasma, and whole blood. The general method was to spike stable isotope labeled analogs of each analyte into the spray solvent, while the analyte itself was in the dried biofluid. Intensity of the labeled analog is proportional to ionization efficiency, whereas the ratio of the analyte intensity to the labeled analog in the spray solvent is proportional to recovery. Ion suppression and recovery were found to be compound- and matrix-dependent. Highest levels of ion suppression were obtained for poor ionizers (e.g., analytes lacking basic aliphatic amine groups) in urine and approached -90%. Ion suppression was much lower or even absent for good ionizers (analytes with aliphatic amines) in dried blood spots. Recovery was generally highest in urine and lowest in blood. We also examined the effect of two experimental parameters on ion suppression and recovery: the spray solvent and the sample position (how far away from the paper tip the dried sample was spotted). Finally, the change in ion suppression and analyte elution as a function of time was examined by carrying out a paper spray analysis of dried plasma spots for 5 min by continually replenishing the spray solvent.

  10. Effect of processing on recovery and variability associated with immunochemical analytical methods for multiple allergens in a single matrix: dark chocolate.

    PubMed

    Khuda, Sefat; Slate, Andrew; Pereira, Marion; Al-Taher, Fadwa; Jackson, Lauren; Diaz-Amigo, Carmen; Bigley, Elmer C; Whitaker, Thomas; Williams, Kristina

    2012-05-02

    Immunodetection of allergens in dark chocolate is complicated by interference from the chocolate components. The objectives of this study were to establish reference materials for detecting multiple allergens in dark chocolate and to determine the accuracy and precision of allergen detection by enzyme-linked immunosorbent assay (ELISA) before and after chocolate processing. Defatted peanut flour, whole egg powder, and spray-dried milk were added to melted chocolate at seven incurred levels and tempered for 4 h. Allergen concentrations were measured using commercial ELISA kits. Tempering decreased the detection of casein and β-lactoglobulin (BLG), but had no significant effect on the detection of peanut and egg. Total coefficients of variation were higher in tempered than untempered chocolate for casein and BLG, but total and analytical CVs were comparable for peanut and egg. These findings indicate that processing has a greater effect on recovery and variability of casein and BLG than peanut and egg detection in a dark chocolate matrix.

  11. Matrix solid-phase dispersion coupled with homogeneous ionic liquid microextraction for the determination of sulfonamides in animal tissues using high-performance liquid chromatography.

    PubMed

    Wang, Zhibing; He, Mengyu; Jiang, Chunzhu; Zhang, Fengqing; Du, Shanshan; Feng, Wennan; Zhang, Hanqi

    2015-12-01

    Matrix solid-phase dispersion coupled with homogeneous ionic liquid microextraction was developed and applied to the extraction of some sulfonamides, including sulfamerazine, sulfamethazine, sulfathiazole, sulfachloropyridazine, sulfadoxine, sulfisoxazole, and sulfaphenazole, in animal tissues. High-performance liquid chromatography was applied to the separation and determination of the target analytes. The solid sample was directly treated by matrix solid-phase dispersion and the eluate obtained was treated by homogeneous ionic liquid microextraction. The ionic liquid was used as the extraction solvent in this method, which may result in the improvement of the recoveries of the target analytes. To avoid using organic solvent and reduce environmental pollution, water was used as the elution solvent of matrix solid-phase dispersion. The effects of the experimental parameters on recoveries, including the type and volume of ionic liquid, type of dispersant, ratio of sample to dispersant, pH value of elution solvent, volume of elution solvent, amount of salt in eluate, amount of ion-pairing agent (NH4 PF6 ), and centrifuging time, were evaluated. When the present method was applied to the analysis of animal tissues, the recoveries of the analytes ranged from 85.4 to 118.0%, and the relative standard deviations were lower than 9.30%. The detection limits for the analytes were 4.3-13.4 μg/kg. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Evaluating changes in matrix based, recovery-adjusted concentrations in paired data for pesticides in groundwater

    USGS Publications Warehouse

    Zimmerman, Tammy M.; Breen, Kevin J.

    2012-01-01

    Pesticide concentration data for waters from selected carbonate-rock aquifers in agricultural areas of Pennsylvania were collected in 1993–2009 for occurrence and distribution assessments. A set of 30 wells was visited once in 1993–1995 and again in 2008–2009 to assess concentration changes. The data include censored matched pairs (nondetections of a compound in one or both samples of a pair). A potentially improved approach for assessing concentration changes is presented where (i) concentrations are adjusted with models of matrix-spike recovery and (ii) area-wide temporal change is tested by use of the paired Prentice-Wilcoxon (PPW) statistical test. The PPW results for atrazine, simazine, metolachlor, prometon, and an atrazine degradate, deethylatrazine (DEA), are compared using recovery-adjusted and unadjusted concentrations. Results for adjusted compared with unadjusted concentrations in 2008–2009 compared with 1993–1995 were similar for atrazine and simazine (significant decrease; 95% confidence level) and metolachlor (no change) but differed for DEA (adjusted, decrease; unadjusted, increase) and prometon (adjusted, decrease; unadjusted, no change). The PPW results were different on recovery-adjusted compared with unadjusted concentrations. Not accounting for variability in recovery can mask a true change, misidentify a change when no true change exists, or assign a direction opposite of the true change in concentration that resulted from matrix influences on extraction and laboratory method performance. However, matrix-based models of recovery derived from a laboratory performance dataset from multiple studies for national assessment, as used herein, rather than time- and study-specific recoveries may introduce uncertainty in recovery adjustments for individual samples that should be considered in assessing change.

  13. Novel hydrophobic interaction chromatography matrix for specific isolation and simple elution of immunoglobulins (A, G, and M) from porcine serum.

    PubMed

    Ramos-Clamont, Gabriela; del Carmen Candia-Plata, Maria; Zamudio, Roberto Guzman; Vazquez-Moreno, Luz

    2006-07-28

    A new, highly acetylated agarose matrix (HA-Sepharose) was synthesized and used as a hydrophobic interaction chromatography (HIC) medium to specifically isolate immunoglobulins (Igs) from porcine serum. Recovery of Igs was in a single step and under mild conditions. HA-Sepharose adsorption was studied in terms of salt, gel acetylation time, flow rate, and protein concentration on the loading buffer. At 0.5 M Na2SO4, control with unmodified Sepharose retained a small fraction (0.70 mg/mL of matrix) of serum albumin. On the contrary HA-Sepharose retained primary Igs (IgA, IgG, and 53% of IgM) as revealed by sodium dodecyl sulphate 10% polyacrylamide gel electrophoresis (SDS-PAGE), quantitative radial immunodiffusion and immunodetection. At a flow rate of 1 mL/min, the HA-Sepharose column capacity (3.9 mg/mL of matrix) was similar to the reported capacity for the commercial thiophilic T-gel. However, HA-Sepharose showed higher recovery of IgA and IgM than the T-gel in the same salt conditions, clearly an advantage in terms of immunoglobulin recovery strategies. Acetylation changed the matrix adsorption from albumin to immunoglobulins; thus, the highly acetylated gel rendered recoveries of Igs from unprocessed porcine serum practically free of albumin.

  14. Contrasting recovery patterns of 2, 4-dinitrophenylhydrazones (DNPH) derivative of carbonyls between liquid and gas phase standards using HPLC-based analysis

    NASA Astrophysics Data System (ADS)

    Saha, Subbroto Kumar; Jo, Sang-Hee; Song, Hee-Nam; Brown, Richard J. C.; Kim, Ki-Hyun

    2012-12-01

    This study evaluates the relative recovery (RR) of five different carbonyls (CCs) (i.e., acetaldehyde, propionaldehyde, butyraldehyde, isovaleraldehyde, and valeraldehyde) following their reaction as 2, 4-dinitrophenylhydrazine (DNPH) derivatives when using gas phase and liquid phase standards. To this end, relative efficiency of CC-DNPH derivatization is compared between two liquid-phase standards (commercially available vs. lab made mixture) and between liquid and gas-phase standard. If the results are compared in terms of response factors (RF) derived for five carbonyls from all different standard phases, the recovery of gaseous CC standard was distinguished from that of liquid counterparts. The RR of the heavier carbonyls (propionaldehyde, butyraldehyde, isovaleraldehyde, and valeraldehyde) was approximately 60% low relative to their liquid counterparts; however, it was not the case for the lighter carbonyls (acetaldehyde) with the RR of ˜92%. This study thus suggests that the quantification of heavy carbonyls in ambient air, unless made by standards of the same matrix (i.e., gas phase) or compensated by the proper correction factor, may be subject to a large bias due to difference in derivatization reaction efficiency between matrix types. Hence, consideration of the matrix effect at the calibration stage is of particular importance to measure CC quantitatively.

  15. Chromatographic behavior of co-eluted plasma compounds and effect on screening of drugs by APCI-LC-MS(/MS): Applications to selected cardiovascular drugs.

    PubMed

    Tahboub, Yahya R

    2014-12-01

    Chromatographic behavior of co-eluted compounds from un-extracted drug-free plasma samples was studied by LC-MS and LC-MS/MS with positive APCI. Under soft gradient, total ion chromatogram (TIC) consisted of two major peaks separated by a constant lower intensity region. Early peak (0.15-0.4 min) belongs to polar plasma compounds and consisted of smaller mass ions ( m / z <250); late peak (3.6-4.6 min) belongs to thermally unstable phospholipids and consisted of fragments with m / z <300. Late peak is more sensitive to variations in chromatographic and MS parameters. Screening of most targeted cardiovascular drugs at levels lower than 50 ng/mL has been possible by LC-MS for drugs with retention factors larger than three. Matrix effects and recovery, at 20 and 200 ng/mL, were evaluated for spiked plasma samples with 15 cardiovascular drugs, by MRM-LC-MS/MS. Average recoveries were above 90% and matrix effects expressed as percent matrix factor (% MF) were above 100%, indicating enhancement character for APCI. Large uncertainties were significant for drugs with smaller masses ( m / z <250) and retention factors lower than two.

  16. Evaluation of the QuEChERS method for the extraction of pharmaceuticals and personal care products from drinking-water treatment sludge with determination by UPLC-ESI-MS/MS.

    PubMed

    Cerqueira, Maristela B R; Guilherme, Juliana R; Caldas, Sergiane S; Martins, Manoel L; Zanella, Renato; Primel, Ednei G

    2014-07-01

    A modified version of the QuEChERS method has been evaluated for the determination of 21 pharmaceuticals and 6 personal care products (PPCPs) in drinking-water sludge samples by employing ultra high liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The performance of the method was evaluated through linearity, recovery, precision (intra-day), method detection and quantification limits (MDL and MQL) and matrix effect. The calibration curves prepared in acetonitrile and in the matrix extract showed a correlation coefficient ranging from 0.98 to 0.99. MQLs values were on the ng g(-1) order of magnitude for most compounds. Recoveries between 50% and 93% were reached with RSDs lower than 10% for most compounds. Matrix effect was almost absent with values lower than 16% for 93% of the compounds. By coupling a quick and simple extraction called QuEChERS with the UPLC-MS/MS analysis, a method that is both selective and sensitive was obtained. This methodology was successfully applied to real samples and caffeine and benzophenone-3 were detected in ng g(-1) levels. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Nogo-66 Receptor Antagonist Peptide (NEP1-40) Administration Promotes Functional Recovery and Axonal Growth After Lateral Funiculus Injury in the Adult Rat

    PubMed Central

    Cao, Y.; Shumsky, J. S.; Sabol, M. A.; Kushner, R. A.; Strittmatter, S.; Hamers, F. P. T.; Lee, D. H. S.; Rabacchi, S. A.; Murray, M.

    2010-01-01

    Objective The myelin protein Nogo inhibits axon regeneration by binding to its receptor (NgR) on axons. Intrathecal delivery of an NgR antagonist (NEP1-40) promotes growth of injured corticospinal axons and recovery of motor function following a dorsal hemisection. The authors used a similar design to examine recovery and repair after a lesion that interrupts the rubrospinal tract (RST). Methods Rats received a lateral funiculotomy at C4 and NEP1-40 or vehicle was delivered to the cervical spinal cord for 4 weeks. Outcome measures included motor and sensory tests and immunohistochemistry. Results Gait analysis showed recovery in the NEP1-40-treated group compared to operated controls, and a test of forelimb usage also showed a beneficial effect. The density of labeled RST axons increased ipsilaterally in the NEP1-40 group in the lateral funiculus rostral to the lesion and contralaterally in both gray and white matter. Thus, rubrospinal axons exhibited diminished dieback and/or growth up to the lesion site. This was accompanied by greater density of 5 HT and calcitonin gene-related peptide axons adjacent to and into the lesion/matrix site in the NEP1-40 group. Conclusions NgR blockade after RST injury is associated with axonal growth and/or diminished dieback of severed RST axons up to but not into or beyond the lesion/matrix site, and growth of serotonergic and dorsal root axons adjacent to and into the lesion/matrix site. NgR blockade also supported partial recovery of function. The authors’ results indicate that severed rubrospinal axons respond to NEP1-40 treatment but less robustly than corticospinal, raphe-spinal, or dorsal root axons. PMID:18056009

  18. [Research on partial least squares for determination of impurities in the presence of high concentration of matrix by ICP-AES].

    PubMed

    Wang, Yan-peng; Gong, Qi; Yu, Sheng-rong; Liu, You-yan

    2012-04-01

    A method for detecting trace impurities in high concentration matrix by ICP-AES based on partial least squares (PLS) was established. The research showed that PLS could effectively correct the interference caused by high level of matrix concentration error and could withstand higher concentrations of matrix than multicomponent spectral fitting (MSF). When the mass ratios of matrix to impurities were from 1 000 : 1 to 20 000 : 1, the recoveries of standard addition were between 95% and 105% by PLS. For the system in which interference effect has nonlinear correlation with the matrix concentrations, the prediction accuracy of normal PLS method was poor, but it can be improved greatly by using LIN-PPLS, which was based on matrix transformation of sample concentration. The contents of Co, Pb and Ga in stream sediment (GBW07312) were detected by MSF, PLS and LIN-PPLS respectively. The results showed that the prediction accuracy of LIN-PPLS was better than PLS, and the prediction accuracy of PLS was better than MSF.

  19. The phase transition of matrix recovery from Gaussian measurements matches the minimax MSE of matrix denoising.

    PubMed

    Donoho, David L; Gavish, Matan; Montanari, Andrea

    2013-05-21

    Let X(0) be an unknown M by N matrix. In matrix recovery, one takes n < MN linear measurements y(1),…,y(n) of X(0), where y(i) = Tr(A(T)iX(0)) and each A(i) is an M by N matrix. A popular approach for matrix recovery is nuclear norm minimization (NNM): solving the convex optimization problem min ||X||*subject to y(i) =Tr(A(T)(i)X) for all 1 ≤ i ≤ n, where || · ||* denotes the nuclear norm, namely, the sum of singular values. Empirical work reveals a phase transition curve, stated in terms of the undersampling fraction δ(n,M,N) = n/(MN), rank fraction ρ=rank(X0)/min {M,N}, and aspect ratio β=M/N. Specifically when the measurement matrices Ai have independent standard Gaussian random entries, a curve δ*(ρ) = δ*(ρ;β) exists such that, if δ > δ*(ρ), NNM typically succeeds for large M,N, whereas if δ < δ*(ρ), it typically fails. An apparently quite different problem is matrix denoising in Gaussian noise, in which an unknown M by N matrix X(0) is to be estimated based on direct noisy measurements Y =X(0) + Z, where the matrix Z has independent and identically distributed Gaussian entries. A popular matrix denoising scheme solves the unconstrained optimization problem min|| Y-X||(2)(F)/2+λ||X||*. When optimally tuned, this scheme achieves the asymptotic minimax mean-squared error M(ρ;β) = lim(M,N → ∞)inf(λ)sup(rank(X) ≤ ρ · M)MSE(X,X(λ)), where M/N → . We report extensive experiments showing that the phase transition δ*(ρ) in the first problem, matrix recovery from Gaussian measurements, coincides with the minimax risk curve M(ρ)=M(ρ;β) in the second problem, matrix denoising in Gaussian noise: δ*(ρ)=M(ρ), for any rank fraction 0 < ρ < 1 (at each common aspect ratio β). Our experiments considered matrices belonging to two constraint classes: real M by N matrices, of various ranks and aspect ratios, and real symmetric positive-semidefinite N by N matrices, of various ranks.

  20. Optimized Projection Matrix for Compressive Sensing

    NASA Astrophysics Data System (ADS)

    Xu, Jianping; Pi, Yiming; Cao, Zongjie

    2010-12-01

    Compressive sensing (CS) is mainly concerned with low-coherence pairs, since the number of samples needed to recover the signal is proportional to the mutual coherence between projection matrix and sparsifying matrix. Until now, papers on CS always assume the projection matrix to be a random matrix. In this paper, aiming at minimizing the mutual coherence, a method is proposed to optimize the projection matrix. This method is based on equiangular tight frame (ETF) design because an ETF has minimum coherence. It is impossible to solve the problem exactly because of the complexity. Therefore, an alternating minimization type method is used to find a feasible solution. The optimally designed projection matrix can further reduce the necessary number of samples for recovery or improve the recovery accuracy. The proposed method demonstrates better performance than conventional optimization methods, which brings benefits to both basis pursuit and orthogonal matching pursuit.

  1. Optimization of microwave-assisted extraction and supercritical fluid extraction of carbamate pesticides in soil by experimental design methodology.

    PubMed

    Sun, Lei; Lee, Hian Kee

    2003-10-03

    Orthogonal array design (OAD) was applied for the first time to optimize microwave-assisted extraction (MAE) and supercritical fluid extraction (SFE) conditions for the analysis of four carbamates (propoxur, propham, methiocarb, chlorpropham) from soil. The theory and methodology of a new OA16 (4(4)) matrix derived from a OA16 (2(15)) matrix were developed during the MAE optimization. An analysis of variance technique was employed as the data analysis strategy in this study. Determinations of analytes were completed using high-performance liquid chromatography (HPLC) with UV detection. Four carbamates were successfully extracted from soil with recoveries ranging from 85 to 105% with good reproducibility (approximately 4.9% RSD) under the optimum MAE conditions: 30 ml methanol, 80 degrees C extraction temperature, and 6-min microwave heating. An OA8 (2(7)) matrix was employed for the SFE optimization. The average recoveries and RSD of the analytes from spiked soil by SFE were 92 and 5.5%, respectively except for propham (66.3+/-7.9%), under the following conditions: heating for 30 min at 60 degrees C under supercritical CO2 at 300 kg/cm2 modified with 10% (v/v) methanol. The composition of the supercritical fluid was demonstrated to be a crucial factor in the extraction. The addition of a small volume (10%) of methanol to CO2 greatly enhanced the recoveries of carbamates. A comparison of MAE with SFE was also conducted. The results indicated that >85% average recoveries were obtained by both optimized extraction techniques, and slightly higher recoveries of three carbamates (propoxur, propham and methiocarb) were achieved using MAE. SFE showed slightly higher recovery for chlorpropham (93 vs. 87% for MAE). The effects of time-aged soil on the extraction of analytes were examined and the results obtained by both methods were also compared.

  2. Subspace aware recovery of low rank and jointly sparse signals

    PubMed Central

    Biswas, Sampurna; Dasgupta, Soura; Mudumbai, Raghuraman; Jacob, Mathews

    2017-01-01

    We consider the recovery of a matrix X, which is simultaneously low rank and joint sparse, from few measurements of its columns using a two-step algorithm. Each column of X is measured using a combination of two measurement matrices; one which is the same for every column, while the the second measurement matrix varies from column to column. The recovery proceeds by first estimating the row subspace vectors from the measurements corresponding to the common matrix. The estimated row subspace vectors are then used to recover X from all the measurements using a convex program of joint sparsity minimization. Our main contribution is to provide sufficient conditions on the measurement matrices that guarantee the recovery of such a matrix using the above two-step algorithm. The results demonstrate quite significant savings in number of measurements when compared to the standard multiple measurement vector (MMV) scheme, which assumes same time invariant measurement pattern for all the time frames. We illustrate the impact of the sampling pattern on reconstruction quality using breath held cardiac cine MRI and cardiac perfusion MRI data, while the utility of the algorithm to accelerate the acquisition is demonstrated on MR parameter mapping. PMID:28630889

  3. Determination of tamoxifen and endoxifen in dried blood spots using LC-MS/MS and the effect of coated DBS cards on recovery and matrix effects.

    PubMed

    Jager, Nynke Gl; Rosing, Hilde; Schellens, Jan Hm; Beijnen, Jos H

    2014-01-01

    We developed an HPLC-MS/MS method to quantify tamoxifen (2.5-250 ng/ml) and its metabolite (Z)-endoxifen (0.5-50 ng/ml) in dried blood spots. Extraction recovery of both analytes from Whatman DMPK-A cards was 100% and consistent over time, however, recovery of (Z)-endoxifen from Whatman 903 cards was incomplete and increased upon storage. When SDS, a constituent of the DMPK-A coating, was present during the extraction, recovery improved. The method using DMPK-A cards was validated using bioanalytical guidelines. Additionally, influence of haematocrit (0.29-0.48 L/L), spot volume (20-50 µl) and homogeneity was within limits and both analytes were stable in DBS for at least 4 months. The method for the quantification of tamoxifen and (Z)-endoxifen in DBS collected on DMPK-A cards was successfully validated.

  4. A multi-residue method for pesticides analysis in green coffee beans using gas chromatography-negative chemical ionization mass spectrometry in selective ion monitoring mode.

    PubMed

    Pizzutti, Ionara R; de Kok, Andre; Dickow Cardoso, Carmem; Reichert, Bárbara; de Kroon, Marijke; Wind, Wouter; Weber Righi, Laís; Caiel da Silva, Rosselei

    2012-08-17

    In this study, a new gas chromatography-mass spectrometry (GC-MS) method, using the very selective negative chemical ionization (NCI) mode, was developed and applied in combination with a modified acetonitrile-based extraction method (QuEChERS) for the analysis of a large number of pesticide residues (51 pesticides, including isomers and degradation products) in green coffee beans. A previously developed integrated sample homogenization and extraction method for both pesticides and mycotoxins analysis was used. An homogeneous slurry of green milled coffee beans and water (ratio 1:4, w/w) was prepared and extracted with acetonitrile/acetic acid (1%), followed by magnesium sulfate addition for phase separation. Aliquots from this extract could be used directly for LC-MS/MS analysis of mycotoxins and LC-amenable pesticides. For GC-MS analysis, a further clean-up was necessary. C18- and PSA-bonded silica were tested as dispersive solid-phase extraction (d-SPE) sorbents, separate and as a mixture, and the best results were obtained using C18-bonded silica. For the optimal sensitivity and selectivity, GC-MS detection in the NCI-selected ion monitoring (SIM) mode had to be used to allow the fast analysis of the difficult coffee bean matrix. The validation was performed by analyzing recovery samples at three different spike concentrations, 10, 20 and 50 μg kg(-1), with 6 replicates (n=6) at each concentration. Linearity (r(2)) of calibration curves, estimated instrument and method limits of detection and limits of quantification (LOD(i), LOD(m), LOQ(i) and LOQ(m), respectively), accuracy (as recovery %), precision (as RSD%) and matrix effects (%) were determined for each individual pesticide. From the 51 analytes (42 parent pesticides, 4 isomers and 5 degradation products) determined by GC-MS (NCI-SIM), approximately 76% showed average recoveries between 70-120% and 75% and RSD ≤ 20% at the lowest spike concentration of 10 μg kg(-1), the target method LOQ. For the spike concentrations of 20 and 50 μg kg(-1), the recoveries and RSDs were even better. The validated LOQ(m) was 10, 20 and 50 μg kg(-1) for respectively 33, 3 and 6 of the analytes studied. For five compounds, the European Union method performance requirements for the validation of a quantitative method (average recoveries between 70-120% and repeatability RSD ≤ 20%) were not achieved and 4 problematic pesticides (captan, captafol, folpet and dicofol) could not be detected as their parent compound, but only via their degradation products. Although the matrix effect (matrix-enhanced detector response) was high for all pesticides studied, the matrix interference was minimal, due to the high selectivity obtained with the GC-NCI-MS detection. Matrix-matched calibration for applying the method in routine analysis is recommended for reliable quantitative results. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. Cognitive performance and aphasia recovery.

    PubMed

    Fonseca, José; Raposo, Ana; Martins, Isabel Pavão

    2018-03-01

    Objectives This study assessed cognitive performance of subjects with aphasia during the acute stage of stroke and evaluated how such performance relates to recovery at 3 months. Materials & methods Patients with aphasia following a left hemisphere stroke were evaluated during the first (baseline) and the fourth-month post onset. Assessment comprised non-verbal tests of attention/processing speed (Symbol Search, Cancelation Task), executive functioning (Matrix Reasoning, Tower of Hanoi, Clock Drawing, Motor Initiative), semantic (Camel and Cactus Test), episodic and immediate memory (Memory for Faces Test, 5 Objects Memory Test, and Spatial Span. Recovery was measured by the Token Test score at 3 months. The impact of baseline performance on recovery was evaluated by logistic regression adjusting for age, education, severity of aphasia and the Alberta Stroke Program Early CT (ASPECT) score. Results Thirty-nine subjects (with a mean of 66.5 ± 10.6 years of age, 17 men) were included. Average baseline cognitive performance was within normal range in all tests except in memory tests (semantic, episodic and immediate memory) for which scores were ≤-1.5sd. Subjects with poor aphasia recovery (N = 27) were older and had fewer years of formal education but had identical ASPECT score compared to those with favorable recovery. Considering each test individually, the score obtained on the Matrix Reasoning test was the only one to predict aphasia recovery (Exp(B)=24.085 p = 0.038). Conclusions The Matrix Reasoning Test may contribute to predict aphasia recovery. Cognitive performance is a measure of network disruption but may also indicate the availability of recovery strategies.

  6. A sensitive chemiluminescence enzyme immunoassay based on molecularly imprinted polymers solid-phase extraction of parathion.

    PubMed

    Chen, Ge; Jin, Maojun; Du, Pengfei; Zhang, Chan; Cui, Xueyan; Zhang, Yudan; She, Yongxin; Shao, Hua; Jin, Fen; Wang, Shanshan; Zheng, Lufei; Wang, Jing

    2017-08-01

    The chemiluminescence enzyme immunoassay (CLEIA) method responds differently to various sample matrices because of the matrix effect. In this work, the CLEIA method was coupled with molecularly imprinted polymers (MIPs) synthesized by precipitation polymerization to study the matrix effect. The sample recoveries ranged from 72.62% to 121.89%, with a relative standard deviation (RSD) of 3.74-18.14%.The ratio of the sample matrix-matched standard curve slope rate to the solvent standard curve slope was 1.21, 1.12, 1.17, and 0.85 for apple, rice, orange and cabbage in samples pretreated with the mixture of PSA and C 18 . However, the ratio of sample (apple, rice, orange, and cabbage) matrix-matched standard-MIPs curve slope rate to the solvent standard curve was 1.05, 0.92, 1.09, and 1.05 in samples pretreated with MIPs, respectively. The results demonstrated that the matrices of the samples greatly interfered with the detection of parathion residues by CLEIA. The MIPs bound specifically to the parathion in the samples and eliminated the matrix interference effect. Therefore, the CLEIA method have successfully applied MIPs in sample pretreatment to eliminate matrix interference effects and provided a new sensitive assay for agro-products. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Matrix solid-phase dispersion technique for the determination of a new antiallergic drug, bilastine, in rat faeces.

    PubMed

    Berrueta, L A; Fernández-Armentia, M; Bakkali, A; Gonzalo, A; Lucero, M L; Orjales, A

    2001-08-25

    A matrix solid-phase dispersion (MSPD) procedure for the isolation and HPLC determination of a new antiallergic agent, bilastine, in rat faeces is presented. The effect on recovery of empirical variables such as nature, pH and volume of the washing and elution liquids and nature of the adsorbent has been tested. The best recoveries were attained using an octadecylsilyl sorbent, 10 ml of a 0.1 M NaHCO3-Na2CO3 aqueous buffer of pH 10.0 as washing solvent and 10 ml of methanol as elution solvent. The extracts were evaporated to dryness and reconstituted in mobile phase before their injection into a HPLC system, equipped with a Discovery RP-amide C16 column and a fluorescence detector. The method allows one to reach recoveries of 95.0% within the concentration range 0.05-10 microg/g, with within-day repeatabilities of less than 5% and between-day repeatabilities of less than 9% within this range. This method has been successfully applied to the excretion studies of bilastine in the rat.

  8. Development and validation of an LC-UV method for the determination of sulfonamides in animal feeds.

    PubMed

    Kumar, P; Companyó, R

    2012-05-01

    A simple LC-UV method was developed for the determination of residues of eight sulfonamides (sulfachloropyridazine, sulfadiazine, sulfadimidine, sulfadoxine, sulfamethoxypyridazine, sulfaquinoxaline, sulfamethoxazole, and sulfadimethoxine) in six types of animal feed. C18, Oasis HLB, Plexa and Plexa PCX stationary phases were assessed for the clean-up step and the latter was chosen as it showed greater efficiency in the clean-up of interferences. Feed samples spiked with sulfonamides at 2 mg/kg were used to assess the trueness (recovery %) and precision of the method. Mean recovery values ranged from 47% to 66%, intra-day precision (RSD %) from 4% to 15% and inter-day precision (RSD %) from 7% to 18% in pig feed. Recoveries and intra-day precisions were also evaluated in rabbit, hen, cow, chicken and piglet feed matrices. Calibration curves with standards prepared in mobile phase and matrix-matched calibration curves were compared and the matrix effects were ascertained. The limits of detection and quantification in the feeds ranged from 74 to 265 µg/kg and from 265 to 868 µg/kg, respectively. Copyright © 2011 John Wiley & Sons, Ltd.

  9. Systematic Assessment of Seven Solvent and Solid-Phase Extraction Methods for Metabolomics Analysis of Human Plasma by LC-MS

    NASA Astrophysics Data System (ADS)

    Sitnikov, Dmitri G.; Monnin, Cian S.; Vuckovic, Dajana

    2016-12-01

    The comparison of extraction methods for global metabolomics is usually executed in biofluids only and focuses on metabolite coverage and method repeatability. This limits our detailed understanding of extraction parameters such as recovery and matrix effects and prevents side-by-side comparison of different sample preparation strategies. To address this gap in knowledge, seven solvent-based and solid-phase extraction methods were systematically evaluated using standard analytes spiked into both buffer and human plasma. We compared recovery, coverage, repeatability, matrix effects, selectivity and orthogonality of all methods tested for non-lipid metabolome in combination with reversed-phased and mixed-mode liquid chromatography mass spectrometry analysis (LC-MS). Our results confirmed wide selectivity and excellent precision of solvent precipitations, but revealed their high susceptibility to matrix effects. The use of all seven methods showed high overlap and redundancy which resulted in metabolite coverage increases of 34-80% depending on LC-MS method employed as compared to the best single extraction protocol (methanol/ethanol precipitation) despite 7x increase in MS analysis time and sample consumption. The most orthogonal methods to methanol-based precipitation were ion-exchange solid-phase extraction and liquid-liquid extraction using methyl-tertbutyl ether. Our results help facilitate rational design and selection of sample preparation methods and internal standards for global metabolomics.

  10. Systematic Assessment of Seven Solvent and Solid-Phase Extraction Methods for Metabolomics Analysis of Human Plasma by LC-MS

    PubMed Central

    Sitnikov, Dmitri G.; Monnin, Cian S.; Vuckovic, Dajana

    2016-01-01

    The comparison of extraction methods for global metabolomics is usually executed in biofluids only and focuses on metabolite coverage and method repeatability. This limits our detailed understanding of extraction parameters such as recovery and matrix effects and prevents side-by-side comparison of different sample preparation strategies. To address this gap in knowledge, seven solvent-based and solid-phase extraction methods were systematically evaluated using standard analytes spiked into both buffer and human plasma. We compared recovery, coverage, repeatability, matrix effects, selectivity and orthogonality of all methods tested for non-lipid metabolome in combination with reversed-phased and mixed-mode liquid chromatography mass spectrometry analysis (LC-MS). Our results confirmed wide selectivity and excellent precision of solvent precipitations, but revealed their high susceptibility to matrix effects. The use of all seven methods showed high overlap and redundancy which resulted in metabolite coverage increases of 34–80% depending on LC-MS method employed as compared to the best single extraction protocol (methanol/ethanol precipitation) despite 7x increase in MS analysis time and sample consumption. The most orthogonal methods to methanol-based precipitation were ion-exchange solid-phase extraction and liquid-liquid extraction using methyl-tertbutyl ether. Our results help facilitate rational design and selection of sample preparation methods and internal standards for global metabolomics. PMID:28000704

  11. Long-term Behavior of Hydrocarbon Production Curves

    NASA Astrophysics Data System (ADS)

    Lovell, A.; Karra, S.; O'Malley, D.; Viswanathan, H. S.; Srinivasan, G.

    2017-12-01

    Recovering hydrocarbons (such as natural gas) from naturally-occurring formations with low permeability has had a huge impact on the energy sector, however, recovery rates are low due to poor understanding of recovery and transport mechanisms [1]. The physical mechanisms that control the production of hydrocarbon are only partially understood. Calculations have shown that the short-term behavior in the peak of the production curve is understood to come from the free hydrocarbons in the fracture networks, but the long-term behavior of these curves is often underpredicted [2]. This behavior is thought to be due to small scale processes - such as matrix diffusion, desorption, and connectivity in the damage region around the large fracture network. In this work, we explore some of these small-scale processes using discrete fracture networks (DFN) and the toolkit dfnWorks [3], the matrix diffusion, size of the damage region, and distribution of free gas between the fracture networks and rock matrix. Individual and combined parameter spaces are explored, and comparisons of the resulting production curves are made to experimental site data from the Haynesville formation [4]. We find that matrix diffusion significantly controls the shape of the tail of the production curve, while the distribution of free gas impacts the relative magnitude of the peak to the tail. The height of the damage region has no effect on the shape of the tail. Understanding the constrains of the parameter space based on site data is the first step in rigorously quantifying the uncertainties coming from these types of systems, which can in turn optimize and improve hydrocarbon recovery. [1] C. McGlade, et. al., (2013) Methods of estimating shale gas resources - comparison, evaluation, and implications, Energy, 59, 116-125 [2] S. Karra, et. al., (2015) Effect of advective flow in fractures and matrix diffusion on natural gas production, Water Resources Research, 51(10), 8646-8657 [3] J.D. Hyman, et. al., (2015) dfnworks: A discrete fracture network framework for modeling subsurface flow and transport, Computers & Geosciences, 84, 10-19 [4] E.J. Moniz, et. al., (2011) The future of natural gas, Cambridge, MA, Massachusetts Institute of Technology

  12. Pore-level influence of micro-fracture parameters on visco-capillary behavior of two-phase displacements in porous media

    NASA Astrophysics Data System (ADS)

    Rokhforouz, M. R.; Akhlaghi Amiri, H. A.

    2018-03-01

    In this work, coupled Cahn-Hilliard phase field and Navier-Stokes equations were solved using finite element method to address the effects of micro-fracture and its characterizations on water-oil displacements in a heterogeneous porous medium. Sensitivity studies at a wide range of viscosity ratios (M) and capillary numbers (Ca), and the resultant log Ca-log M stability phase diagram, revealed that in both media, with/without fracture, the three regimes of viscous fingering, capillary fingering and stable displacement similarly occur. However, presence of the fracture caused water channeling phenomenon which resulted in reduction of the number of active fingers and hence the final oil recovery factor. At high Ca (especially in the stable regime, with log Ca ≥ -2.5 and log M ≥ 0), recovery factor for the fractured medium was relatively identical with the non-fractured one. At log M ≥ 0, the fracture was fully swept, but flow instabilities were observed inside the fracture at lower M values, especially for log Ca > -4.6. In the case of the fractured medium at log Ca = -4.6 and log M = 0 (capillary dominant flow), it is observed that the primary breakthrough took place by a finger progressed through the matrix, not those channeled through the fracture. Geometrical properties of the fracture, including length, aperture and orientation, highly affected both displacement profile and efficiency. The fracture length inversely influenced the oil recovery factor. It was observed that there is a critical fracture width (almost half of the medium average pore diameter) at which the recovery factor of the medium during displacement is minimum, compared to the media having thinner and thicker fractures. Minor channeling effect in the media with thinner fracture and larger fracture swept volume as well as high fracture/matrix cross flow in the media with thicker fracture were detected as the main cause of this non-monotonic behavior. In the models with thick fractures (with the thickness higher than the average pore diameter), considerable trapped oil volumes were observed inside the fracture at low M values. The fracture orientation had the most impressive effect on oil recovery compared to the other studied parameters; where the oil recovery factor incremented more than 20% as the fracture rotated 90° from flow direction. Due to the dominant effect of the channeling phenomenon, the change in the medium wettability from slightly oil-wet to slightly water-wet, did not considerably affect the displacement profile in the fractured medium. However, oil recovery factor increased as the medium became more water-wet. The fracture area was fully swept by the injected water in the oil-wet and neutral-wet media. However, flow instabilities were observed inside the fracture of the water-wet medium due to counter-current imbibition between fracture/matrix. Micro-scale mechanisms of pore doublet effect, interface coalesce, snap-off and reverse movements were captured during the studied unstable displacements.

  13. Cell-wall recovery after irreversible deformation of wood

    NASA Astrophysics Data System (ADS)

    Keckes, Jozef; Burgert, Ingo; Frühmann, Klaus; Müller, Martin; Kölln, Klaas; Hamilton, Myles; Burghammer, Manfred; Roth, Stephan V.; Stanzl-Tschegg, Stefanie; Fratzl, Peter

    2003-12-01

    The remarkable mechanical properties of biological materials reside in their complex hierarchical architecture and in specific molecular mechanistic phenomena. The fundamental importance of molecular interactions and bond recovery has been suggested by studies on deformation and fracture of bone and nacre. Like these mineral-based materials, wood also represents a complex nanocomposite with excellent mechanical performance, despite the fact that it is mainly based on polymers. In wood, however, the mechanistic contribution of processes in the cell wall is not fully understood. Here we have combined tensile tests on individual wood cells and on wood foils with simultaneous synchrotron X-ray diffraction analysis in order to separate deformation mechanisms inside the cell wall from those mediated by cell-cell interactions. We show that tensile deformation beyond the yield point does not deteriorate the stiffness of either individual cells or foils. This indicates that there is a dominant recovery mechanism that re-forms the amorphous matrix between the cellulose microfibrils within the cell wall, maintaining its mechanical properties. This stick-slip mechanism, rather like Velcro operating at the nanometre level, provides a 'plastic response' similar to that effected by moving dislocations in metals. We suggest that the molecular recovery mechanism in the cell matrix is a universal phenomenon dominating the tensile deformation of different wood tissue types.

  14. Learning to rank image tags with limited training examples.

    PubMed

    Songhe Feng; Zheyun Feng; Rong Jin

    2015-04-01

    With an increasing number of images that are available in social media, image annotation has emerged as an important research topic due to its application in image matching and retrieval. Most studies cast image annotation into a multilabel classification problem. The main shortcoming of this approach is that it requires a large number of training images with clean and complete annotations in order to learn a reliable model for tag prediction. We address this limitation by developing a novel approach that combines the strength of tag ranking with the power of matrix recovery. Instead of having to make a binary decision for each tag, our approach ranks tags in the descending order of their relevance to the given image, significantly simplifying the problem. In addition, the proposed method aggregates the prediction models for different tags into a matrix, and casts tag ranking into a matrix recovery problem. It introduces the matrix trace norm to explicitly control the model complexity, so that a reliable prediction model can be learned for tag ranking even when the tag space is large and the number of training images is limited. Experiments on multiple well-known image data sets demonstrate the effectiveness of the proposed framework for tag ranking compared with the state-of-the-art approaches for image annotation and tag ranking.

  15. Evaluation of a molecularly imprinted polymer for determination of steroids in goat milk by matrix solid phase dispersion.

    PubMed

    Gañán, Judith; Morante-Zarcero, Sonia; Gallego-Picó, Alejandrina; Garcinuño, Rosa María; Fernández-Hernando, Pilar; Sierra, Isabel

    2014-08-01

    A molecularly imprinted polymer-matrix solid-phase dispersion methodology for simultaneous determination of five steroids in goat milk samples was proposed. Factors affecting the extraction recovery such as sample/dispersant ratio and washing and elution solvents were investigated. The molecularly imprinted polymer used as dispersant in the matrix solid-phase dispersion procedure showed high affinity to steroids, and the obtained extracts were sufficiently cleaned to be directly analyzed. Analytical separation was performed by micellar electrokinetic chromatography using a capillary electrophoresis system equipped with a diode array detector. A background electrolyte composed of borate buffer (25mM, pH 9.3), sodium dodecyl sulfate (10mM) and acetonitrile (20%) was used. The developed MIP-MSPD methodology was applied for direct determination of testosterone (T), estrone (E1), 17β-estradiol (17β-E2), 17α-ethinylestradiol (EE2) and progesterone (P) in different goat milk samples. Mean recoveries obtained ranged from 81% to 110%, with relative standard deviations (RSD)≤12%. The molecularly imprinted polymer-matrix solid-phase dispersion method is fast, selective, cost-effective and environment-friendly compared with other pretreatment methods used for extraction of steroids in milk. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Active mode-locking of mid-infrared quantum cascade lasers with short gain recovery time.

    PubMed

    Wang, Yongrui; Belyanin, Alexey

    2015-02-23

    We investigate the dynamics of actively modulated mid-infrared quantum cascade lasers (QCLs) using space- and time-domain simulations of coupled density matrix and Maxwell equations with resonant tunneling current taken into account. We show that it is possible to achieve active mode locking and stable generation of picosecond pulses in high performance QCLs with a vertical laser transition and a short gain recovery time by bias modulation of a short section of a monolithic Fabry-Perot cavity. In fact, active mode locking in QCLs with a short gain recovery time turns out to be more robust to the variation of parameters as compared to previously studied lasers with a long gain recovery time. We investigate the effects of spatial hole burning and phase locking on the laser output.

  17. Fibercore AstroGain fiber: multichannel erbium doped fibers for optical space communications

    NASA Astrophysics Data System (ADS)

    Hill, Mark; Gray, Rebecca; Hankey, Judith; Gillooly, Andy

    2014-03-01

    Fibercore have developed AstroGainTM fiber optimized for multichannel amplifiers used in optical satellite communications and control. The fiber has been designed to take full advantage of the photo-annealing effect that results from pumping in the 980nm region. The proprietary trivalent structure of the core matrix allows optimum recovery following radiation damage to the fiber, whilst also providing a market leading Erbium Doped Fiber Amplifier (EDFA) efficiency. Direct measurements have been taken of amplifier efficiency in a multichannel assembly, which show an effective photo-annealing recovery of up to 100% of the radiation induced attenuation through excitation of point defects.

  18. Performance of the goulden large-sample extractor in multiclass pesticide isolation and preconcentration from stream water

    USGS Publications Warehouse

    Foster, G.D.; Foreman, W.T.; Gates, Paul M.

    1991-01-01

    The reliability of the Goulden large-sample extractor in preconcentrating pesticides from water was evaluated from the recoveries of 35 pesticides amended to filtered stream waters. Recoveries greater than 90% were observed for many of the pesticides in each major chemical class, but recoveries for some of the individual pesticides varied in seemingly unpredictable ways. Corrections cannot yet be factored into liquid-liquid extraction theory to account for matrix effects, which were apparent between the two stream waters tested. The Goulden large-sample extractor appears to be well suited for rapid chemical screening applications, with quantitative analysis requiring special quality control considerations. ?? 1991 American Chemical Society.

  19. Scytonemin Plays a Potential Role in Stabilizing the Exopolysaccharidic Matrix in Terrestrial Cyanobacteria.

    PubMed

    Gao, Xiang

    2017-02-01

    Cyanobacteria are photosynthetic oxygen-evolving prokaryotes that are distributed in diverse habitats. They synthesize the ultraviolet (UV)-screening pigments, scytonemin (SCY) and mycosporine-like amino acids (MAAs), located in the exopolysaccharide (EPS) matrix. Multiple roles for both pigments have gradually been recognized, such as sunscreen ability, antioxidant activity, and heat dissipation from absorbed UV radiation. In this study, a filamentous terrestrial cyanobacterium Nostoc flagelliforme was used to evaluate the potential stabilizing role of SCY on the EPS matrix. SCY (∼3.7 %) was partially removed from N. flagelliforme filaments by rinsing with 100 % acetone for 5 s. The physiological damage to cells resulting from this treatment, in terms of photosystem II activity parameter Fv/Fm, was repaired after culturing the sample for 40 h. The physiologically recovered sample was further desiccated by natural or rapid drying and then allowed to recovery for 24 h. Compared with the normal sample, a relatively slower Fv/Fm recovery was observed in the SCY-partially removed sample, suggesting that the decreased SCY concentration in the EPS matrix caused cells to suffer further damage upon desiccation. In addition, the SCY-partially removed sample could allow the release of MAAs (∼25 %) from the EPS matrix, while the normal sample did not. Therefore, damage caused by drying of the former resulted from at least the reduction of structural stability of the EPS matrix as well as the loss of partial antioxidant compounds. Considering that an approximately 4 % loss of SCY led to this significant effect, the structurally stabilizing potential of SCY on the EPS matrix is crucial for terrestrial cyanobacteria survival in complex environments.

  20. The contribution of lot-to-lot variation to the measurement uncertainty of an LC-MS-based multi-mycotoxin assay.

    PubMed

    Stadler, David; Sulyok, Michael; Schuhmacher, Rainer; Berthiller, Franz; Krska, Rudolf

    2018-05-01

    Multi-mycotoxin determination by LC-MS is commonly based on external solvent-based or matrix-matched calibration and, if necessary, the correction for the method bias. In everyday practice, the method bias (expressed as apparent recovery RA), which may be caused by losses during the recovery process and/or signal/suppression enhancement, is evaluated by replicate analysis of a single spiked lot of a matrix. However, RA may vary for different lots of the same matrix, i.e., lot-to-lot variation, which can result in a higher relative expanded measurement uncertainty (U r ). We applied a straightforward procedure for the calculation of U r from the within-laboratory reproducibility, which is also called intermediate precision, and the uncertainty of RA (u r,RA ). To estimate the contribution of the lot-to-lot variation to U r , the measurement results of one replicate of seven different lots of figs and maize and seven replicates of a single lot of these matrices, respectively, were used to calculate U r . The lot-to-lot variation was contributing to u r,RA and thus to U r for the majority of the 66 evaluated analytes in both figs and maize. The major contributions of the lot-to-lot variation to u r,RA were differences in analyte recovery in figs and relative matrix effects in maize. U r was estimated from long-term participation in proficiency test schemes with 58%. Provided proper validation, a fit-for-purpose U r of 50% was proposed for measurement results obtained by an LC-MS-based multi-mycotoxin assay, independent of the concentration of the analytes.

  1. Fabric defect detection based on visual saliency using deep feature and low-rank recovery

    NASA Astrophysics Data System (ADS)

    Liu, Zhoufeng; Wang, Baorui; Li, Chunlei; Li, Bicao; Dong, Yan

    2018-04-01

    Fabric defect detection plays an important role in improving the quality of fabric product. In this paper, a novel fabric defect detection method based on visual saliency using deep feature and low-rank recovery was proposed. First, unsupervised training is carried out by the initial network parameters based on MNIST large datasets. The supervised fine-tuning of fabric image library based on Convolutional Neural Networks (CNNs) is implemented, and then more accurate deep neural network model is generated. Second, the fabric images are uniformly divided into the image block with the same size, then we extract their multi-layer deep features using the trained deep network. Thereafter, all the extracted features are concentrated into a feature matrix. Third, low-rank matrix recovery is adopted to divide the feature matrix into the low-rank matrix which indicates the background and the sparse matrix which indicates the salient defect. In the end, the iterative optimal threshold segmentation algorithm is utilized to segment the saliency maps generated by the sparse matrix to locate the fabric defect area. Experimental results demonstrate that the feature extracted by CNN is more suitable for characterizing the fabric texture than the traditional LBP, HOG and other hand-crafted features extraction method, and the proposed method can accurately detect the defect regions of various fabric defects, even for the image with complex texture.

  2. Structured Matrix Completion with Applications to Genomic Data Integration.

    PubMed

    Cai, Tianxi; Cai, T Tony; Zhang, Anru

    2016-01-01

    Matrix completion has attracted significant recent attention in many fields including statistics, applied mathematics and electrical engineering. Current literature on matrix completion focuses primarily on independent sampling models under which the individual observed entries are sampled independently. Motivated by applications in genomic data integration, we propose a new framework of structured matrix completion (SMC) to treat structured missingness by design. Specifically, our proposed method aims at efficient matrix recovery when a subset of the rows and columns of an approximately low-rank matrix are observed. We provide theoretical justification for the proposed SMC method and derive lower bound for the estimation errors, which together establish the optimal rate of recovery over certain classes of approximately low-rank matrices. Simulation studies show that the method performs well in finite sample under a variety of configurations. The method is applied to integrate several ovarian cancer genomic studies with different extent of genomic measurements, which enables us to construct more accurate prediction rules for ovarian cancer survival.

  3. Measurement of macrocyclic trichothecene in floor dust of water-damaged buildings using gas chromatography/tandem mass spectrometry—dust matrix effects

    PubMed Central

    Saito, Rena; Park, Ju-Hyeong; LeBouf, Ryan; Green, Brett J.; Park, Yeonmi

    2017-01-01

    Gas chromatography-tandem mass spectrometry (GC-MS/MS) was used to detect fungal secondary metabolites. Detection of verrucarol, the hydrolysis product of Stachybotrys chartarum macrocyclic trichothecene (MCT), was confounded by matrix effects associated with heterogeneous indoor environmental samples. In this study, we examined the role of dust matrix effects associated with GC-MS/ MS to better quantify verrucarol in dust as a measure of total MCT. The efficiency of the internal standard (ISTD, 1,12-dodecanediol), and application of a matrix-matched standard correction method in measuring MCT in floor dust of water-damaged buildings was additionally examined. Compared to verrucarol, ISTD had substantially higher matrix effects in the dust extracts. The results of the ISTD evaluation showed that without ISTD adjustment, there was a 280% ion enhancement in the dust extracts compared to neat solvent. The recovery of verrucarol was 94% when the matrix-matched standard curve without the ISTD was used. Using traditional calibration curves with ISTD adjustment, none of the 21 dust samples collected from water damaged buildings were detectable. In contrast, when the matrix-matched calibration curves without ISTD adjustment were used, 38% of samples were detectable. The study results suggest that floor dust of water-damaged buildings may contain MCT. However, the measured levels of MCT in dust using the GC-MS/MS method could be significantly under- or overestimated, depending on the matrix effects, the inappropriate ISTD, or combination of the two. Our study further shows that the routine application of matrix-matched calibration may prove useful in obtaining accurate measurements of MCT in dust derived from damp indoor environments, while no isotopically labeled verrucarol is available. PMID:26853932

  4. Measurement of macrocyclic trichothecene in floor dust of water-damaged buildings using gas chromatography/tandem mass spectrometry-dust matrix effects.

    PubMed

    Saito, Rena; Park, Ju-Hyeong; LeBouf, Ryan; Green, Brett J; Park, Yeonmi

    2016-01-01

    Gas chromatography-tandem mass spectrometry (GC-MS/MS) was used to detect fungal secondary metabolites. Detection of verrucarol, the hydrolysis product of Stachybotrys chartarum macrocyclic trichothecene (MCT), was confounded by matrix effects associated with heterogeneous indoor environmental samples. In this study, we examined the role of dust matrix effects associated with GC-MS/MS to better quantify verrucarol in dust as a measure of total MCT. The efficiency of the internal standard (ISTD, 1,12-dodecanediol), and application of a matrix-matched standard correction method in measuring MCT in floor dust of water-damaged buildings was additionally examined. Compared to verrucarol, ISTD had substantially higher matrix effects in the dust extracts. The results of the ISTD evaluation showed that without ISTD adjustment, there was a 280% ion enhancement in the dust extracts compared to neat solvent. The recovery of verrucarol was 94% when the matrix-matched standard curve without the ISTD was used. Using traditional calibration curves with ISTD adjustment, none of the 21 dust samples collected from water damaged buildings were detectable. In contrast, when the matrix-matched calibration curves without ISTD adjustment were used, 38% of samples were detectable. The study results suggest that floor dust of water-damaged buildings may contain MCT. However, the measured levels of MCT in dust using the GC-MS/MS method could be significantly under- or overestimated, depending on the matrix effects, the inappropriate ISTD, or combination of the two. Our study further shows that the routine application of matrix-matched calibration may prove useful in obtaining accurate measurements of MCT in dust derived from damp indoor environments, while no isotopically labeled verrucarol is available.

  5. Compressive sensing based wireless sensor for structural health monitoring

    NASA Astrophysics Data System (ADS)

    Bao, Yuequan; Zou, Zilong; Li, Hui

    2014-03-01

    Data loss is a common problem for monitoring systems based on wireless sensors. Reliable communication protocols, which enhance communication reliability by repetitively transmitting unreceived packets, is one approach to tackle the problem of data loss. An alternative approach allows data loss to some extent and seeks to recover the lost data from an algorithmic point of view. Compressive sensing (CS) provides such a data loss recovery technique. This technique can be embedded into smart wireless sensors and effectively increases wireless communication reliability without retransmitting the data. The basic idea of CS-based approach is that, instead of transmitting the raw signal acquired by the sensor, a transformed signal that is generated by projecting the raw signal onto a random matrix, is transmitted. Some data loss may occur during the transmission of this transformed signal. However, according to the theory of CS, the raw signal can be effectively reconstructed from the received incomplete transformed signal given that the raw signal is compressible in some basis and the data loss ratio is low. This CS-based technique is implemented into the Imote2 smart sensor platform using the foundation of Illinois Structural Health Monitoring Project (ISHMP) Service Tool-suite. To overcome the constraints of limited onboard resources of wireless sensor nodes, a method called random demodulator (RD) is employed to provide memory and power efficient construction of the random sampling matrix. Adaptation of RD sampling matrix is made to accommodate data loss in wireless transmission and meet the objectives of the data recovery. The embedded program is tested in a series of sensing and communication experiments. Examples and parametric study are presented to demonstrate the applicability of the embedded program as well as to show the efficacy of CS-based data loss recovery for real wireless SHM systems.

  6. Determination of 21 drugs in oral fluid using fully automated supported liquid extraction and UHPLC-MS/MS.

    PubMed

    Valen, Anja; Leere Øiestad, Åse Marit; Strand, Dag Helge; Skari, Ragnhild; Berg, Thomas

    2017-05-01

    Collection of oral fluid (OF) is easy and non-invasive compared to the collection of urine and blood, and interest in OF for drug screening and diagnostic purposes is increasing. A high-throughput ultra-high-performance liquid chromatography-tandem mass spectrometry method for determination of 21 drugs in OF using fully automated 96-well plate supported liquid extraction for sample preparation is presented. The method contains a selection of classic drugs of abuse, including amphetamines, cocaine, cannabis, opioids, and benzodiazepines. The method was fully validated for 200 μL OF/buffer mix using an Intercept OF sampling kit; validation included linearity, sensitivity, precision, accuracy, extraction recovery, matrix effects, stability, and carry-over. Inter-assay precision (RSD) and accuracy (relative error) were <15% and 13 to 5%, respectively, for all compounds at concentrations equal to or higher than the lower limit of quantification. Extraction recoveries were between 58 and 76% (RSD < 8%), except for tetrahydrocannabinol and three 7-amino benzodiazepine metabolites with recoveries between 23 and 33% (RSD between 51 and 52 % and 11 and 25%, respectively). Ion enhancement or ion suppression effects were observed for a few compounds; however, to a large degree they were compensated for by the internal standards used. Deuterium-labelled and 13 C-labelled internal standards were used for 8 and 11 of the compounds, respectively. In a comparison between Intercept and Quantisal OF kits, better recoveries and fewer matrix effects were observed for some compounds using Quantisal. The method is sensitive and robust for its purposes and has been used successfully since February 2015 for analysis of Intercept OF samples from 2600 cases in a 12-month period. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  7. Effect of fungal mycelia on the HPLC-UV and UV-vis spectrophotometric assessment of mycelium-bound epoxide hydrolase using glycidyl phenyl ether.

    PubMed

    Dolcet, Marta M; Torres, Mercè; Canela, Ramon

    2016-06-25

    The use of mycelia as biocatalysts has technical and economic advantages. However, there are several difficulties in obtaining accurate results in mycelium-catalysed reactions. Firstly, sample extraction, indispensable because of the presence of mycelia, can bring into the extract components with a similar structure to that of the analyte of interest; secondly, mycelia can influence the recovery of the analyte. We prepared calibration standards of 3-phenoxy-1,2-propanediol (PPD) in the pure solvent and in the presence of mycelia (spiked before or after extraction) from five fungi (Aspergillus niger, Aspergillus tubingensis, Penicillium aurantiogriseum, Penicillium sp. and Aspergillus terreus). The quantification of PPD was carried out by HPLC-UV and UV-vis spectrophotometry. The manuscript shows that the last method is as accurate as the HPLC method. However, the colorimetric method led to a higher data throughput, which allowed the study of more samples in a shorter time. Matrix effects were evaluated visually from the plotted calibration data and statistically by simultaneously comparing the intercept and slope of calibration curves performed with solvent, post-extraction spiked standards and pre-extraction spiked standards. Significant differences were found between the post- and pre-extraction spiked matrix-matched functions. Pre-extraction spiked matrix-matched functions based on A. tubingensis mycelia, selected as the reference, were validated and used to compensate for low recoveries. These validated functions were successfully applied to the quantification of PPD achieved during the hydrolysis of glycidyl phenyl ether by mycelium-bound epoxide hydrolases and equivalent hydrolysis yields were determined by HPLC-UV and UV-vis spectrophotometry. This study may serve as starting point to implement matrix effects evaluation when mycelium-bound epoxide hydrolases are studied. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Hitting a Moving Target: Basic Mechanisms of Recovery from Acquired Developmental Brain Injury

    PubMed Central

    Giza, Christopher C.; Kolb, Bryan; Harris, Neil G.; Asarnow, Robert F.; Prins, Mayumi L.

    2009-01-01

    Acquired brain injuries represent a major cause of disability in the pediatric population. Understanding responses to developmental acquired brain injuries requires knowledge of the neurobiology of normal development, age-at-injury effects and experience-dependent neuroplasticity. In the developing brain, full recovery cannot be considered as a return to the premorbid baseline, since ongoing maturation means that cerebral functioning in normal individuals will continue to advance. Thus, the recovering immature brain has to ‘hit a moving target’ to achieve full functional recovery, defined as parity with age-matched uninjured peers. This review will discuss the consequences of developmental injuries such as focal lesions, diffuse hypoxia and traumatic brain injury (TBI). Underlying cellular and physiological mechanisms relevant to age-at-injury effects will be described in considerable detail, including but not limited to alterations in neurotransmission, connectivity/network functioning, the extracellular matrix, response to oxidative stress and changes in cerebral metabolism. Finally, mechanisms of experience-dependent plasticity will be reviewed in conjunction with their effects on neural repair and recovery. PMID:19956795

  9. The effect of pre-enrichment media on the recovery and detection of Salmonella in feed

    USDA-ARS?s Scientific Manuscript database

    Current methodology for detecting Salmonella in feeds and feed ingredients are adapted from food safety methods. These methods do not take into account the stressed state of Salmonella in feed, presence of competing microorganisms nor the sample matrix. The objective was to evaluate four pre-enrichm...

  10. SELECTIVE RECOVERY OF ETHANOL FROM WATER BY PERVAPORATION: ZEOLITE-SILICONE RUBBER MIXED MATRIX MEMBRANES

    EPA Science Inventory

    The production of fuel-grade ethanol from renewable resources, such as biomass, is gaining attention due to the phase out of methyl t-butyl ether (MTBE) as a fuel oxygenate, national security issues related to non-domestic sources of fuels, and the effect of fossil fuel combustio...

  11. Determination of benzothiazole and benzotriazole derivates in tire and clothing textile samples by high performance liquid chromatography-electrospray ionization tandem mass spectrometry.

    PubMed

    Avagyan, Rozanna; Sadiktsis, Ioannis; Thorsén, Gunnar; Östman, Conny; Westerholm, Roger

    2013-09-13

    A high performance liquid chromatography-tandem mass spectrometry method utilizing electrospray ionization in positive and negative mode has been developed for the separation and detection of benzothiazole and benzotriazole derivates. Ultra-sonication assisted solvent extraction of these compounds has also been developed and the overall method demonstrated on a selected clothing textile and an automobile tire sample. Matrix effects and extraction recoveries, as well as linearity and limits of detection have been evaluated. The calibration curves spanned over more than two orders of magnitude with coefficients of correlation R(2)>0.99 and the limits of detection and the limits of quantification were in the range 1.7-58pg injected and 18-140pg/g, respectively. The extraction recoveries ranged between 69% and 102% and the matrix effects between 75% and 101%. Benzothiazole and benzotriazole derivates were determined in the textile sample and benzothiazole derivatives determined in the tire sample with good analytical performance. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. Evaluation of the impact of matrix effect on quantification of pesticides in foods by gas chromatography-mass spectrometry using isotope-labeled internal standards.

    PubMed

    Yarita, Takashi; Aoyagi, Yoshie; Otake, Takamitsu

    2015-05-29

    The impact of the matrix effect in GC-MS quantification of pesticides in food using the corresponding isotope-labeled internal standards was evaluated. A spike-and-recovery study of nine target pesticides was first conducted using paste samples of corn, green soybean, carrot, and pumpkin. The observed analytical values using isotope-labeled internal standards were more accurate for most target pesticides than that obtained using the external calibration method, but were still biased from the spiked concentrations when a matrix-free calibration solution was used for calibration. The respective calibration curves for each target pesticide were also prepared using matrix-free calibration solutions and matrix-matched calibration solutions with blank soybean extract. The intensity ratio of the peaks of most target pesticides to that of the corresponding isotope-labeled internal standards was influenced by the presence of the matrix in the calibration solution; therefore, the observed slope varied. The ratio was also influenced by the type of injection method (splitless or on-column). These results indicated that matrix-matching of the calibration solution is required for very accurate quantification, even if isotope-labeled internal standards were used for calibration. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Rapid Diffusion of Green Fluorescent Protein in the Mitochondrial Matrix

    PubMed Central

    Partikian, Arthur; Ölveczky, Bence; Swaminathan, R.; Li, Yuxin; Verkman, A.S.

    1998-01-01

    Abstract. It is thought that the high protein density in the mitochondrial matrix results in severely restricted solute diffusion and metabolite channeling from one enzyme to another without free aqueous-phase diffusion. To test this hypothesis, we measured the diffusion of green fluorescent protein (GFP) expressed in the mitochondrial matrix of fibroblast, liver, skeletal muscle, and epithelial cell lines. Spot photobleaching of GFP with a 100× objective (0.8-μm spot diam) gave half-times for fluorescence recovery of 15–19 ms with >90% of the GFP mobile. As predicted for aqueous-phase diffusion in a confined compartment, fluorescence recovery was slowed or abolished by increased laser spot size or bleach time, and by paraformaldehyde fixation. Quantitative analysis of bleach data using a mathematical model of matrix diffusion gave GFP diffusion coefficients of 2–3 × 10−7 cm2/s, only three to fourfold less than that for GFP diffusion in water. In contrast, little recovery was found for bleaching of GFP in fusion with subunits of the fatty acid β-oxidation multienzyme complex that are normally present in the matrix. Measurement of the rotation of unconjugated GFP by time-resolved anisotropy gave a rotational correlation time of 23.3 ± 1 ns, similar to that of 20 ns for GFP rotation in water. A rapid rotational correlation time of 325 ps was also found for a small fluorescent probe (BCECF, ∼0.5 kD) in the matrix of isolated liver mitochondria. The rapid and unrestricted diffusion of solutes in the mitochondrial matrix suggests that metabolite channeling may not be required to overcome diffusive barriers. We propose that the clustering of matrix enzymes in membrane-associated complexes might serve to establish a relatively uncrowded aqueous space in which solutes can freely diffuse. PMID:9472034

  14. Myocardial recovery from ischemia-reperfusion is compromised in the absence of tissue inhibitor of metalloproteinase 4.

    PubMed

    Takawale, Abhijit; Fan, Dong; Basu, Ratnadeep; Shen, Mengcheng; Parajuli, Nirmal; Wang, Wang; Wang, Xiuhua; Oudit, Gavin Y; Kassiri, Zamaneh

    2014-07-01

    Myocardial reperfusion after ischemia (I/R), although an effective approach in rescuing the ischemic myocardium, can itself trigger several adverse effects including aberrant remodeling of the myocardium and its extracellular matrix. Tissue inhibitor of metalloproteinases (TIMPs) protect the extracellular matrix against excess degradation by matrix metalloproteinases (MMPs). TIMP4 levels are reduced in myocardial infarction; however, its causal role in progression of post-I/R injury has not been explored. In vivo I/R (20-minute ischemia, 1-week reperfusion) resulted in more severe systolic and diastolic dysfunction in TIMP4(-/-) mice with enhanced inflammation, oxidative stress (1 day post-I/R), hypertrophy, and interstitial fibrosis (1 week). After an initial increase in TIMP4 (1 day post-I/R), TIMP4 mRNA and protein decreased in the ischemic myocardium from wild-type mice by 1 week post-I/R and in tissue samples from patients with myocardial infarction, which correlated with enhanced activity of membrane-bound MMP, membrane-type 1 MMP. By 4 weeks post-I/R, wild-type mice showed no cardiac dysfunction, elevated TIMP4 levels (to baseline), and normalized membrane-type 1 MMP activity. TIMP4-deficient mice, however, showed exacerbated diastolic dysfunction, sustained elevation of membrane-type 1 MMP activity, and worsened myocardial hypertrophy and fibrosis. Ex vivo I/R (20- or 30-minute ischemia, 45-minute reperfusion) resulted in comparable cardiac dysfunction in wild-type and TIMP4(-/-) mice. TIMP4 is essential for recovery from myocardial I/R in vivo, primarily because of its membrane-type 1 MMP inhibitory function. TIMP4 deficiency does not increase susceptibility to ex vivo I/R injury. Replenishment of myocardial TIMP4 could serve as an effective therapy in post-I/R recovery for patients with reduced TIMP4. © 2014 American Heart Association, Inc.

  15. Determination of pharmaceutical compounds in surface- and ground-water samples by solid-phase extraction and high-performance liquid chromatography-electrospray ionization mass spectrometry

    USGS Publications Warehouse

    Cahill, J.D.; Furlong, E.T.; Burkhardt, M.R.; Kolpin, D.; Anderson, L.G.

    2004-01-01

    Commonly used prescription and over-the-counter pharmaceuticals are possibly present in surface- and ground-water samples at ambient concentrations less than 1 μg/L. In this report, the performance characteristics of a combined solid-phase extraction isolation and high-performance liquid chromatography–electrospray ionization mass spectrometry (HPLC–ESI-MS) analytical procedure for routine determination of the presence and concentration of human-health pharmaceuticals are described. This method was developed and used in a recent national reconnaissance of pharmaceuticals in USA surface waters. The selection of pharmaceuticals evaluated for this method was based on usage estimates, resulting in a method that contains compounds from diverse chemical classes, which presents challenges and compromises when applied as a single routine analysis. The method performed well for the majority of the 22 pharmaceuticals evaluated, with recoveries greater than 60% for 12 pharmaceuticals. The recoveries of angiotensin-converting enzyme inhibitors, a histamine (H2) receptor antagonist, and antihypoglycemic compound classes were less than 50%, but were retained in the method to provide information describing the potential presence of these compounds in environmental samples and to indicate evidence of possible matrix enhancing effects. Long-term recoveries, evaluated from reagent-water fortifications processed over 2 years, were similar to initial method performance. Method detection limits averaged 0.022 μg/L, sufficient for expected ambient concentrations. Compound-dependent matrix effects on HPLC/ESI-MS analysis, including enhancement and suppression of ionization, were observed as a 20–30% increase in measured concentrations for three compounds and greater than 50% increase for two compounds. Changing internal standard and more frequent ESI source maintenance minimized matrix effects. Application of the method in the national survey demonstrates that several pharmaceuticals are routinely detected at 0.010–0.100 μg/L concentrations.

  16. SparRec: An effective matrix completion framework of missing data imputation for GWAS

    NASA Astrophysics Data System (ADS)

    Jiang, Bo; Ma, Shiqian; Causey, Jason; Qiao, Linbo; Hardin, Matthew Price; Bitts, Ian; Johnson, Daniel; Zhang, Shuzhong; Huang, Xiuzhen

    2016-10-01

    Genome-wide association studies present computational challenges for missing data imputation, while the advances of genotype technologies are generating datasets of large sample sizes with sample sets genotyped on multiple SNP chips. We present a new framework SparRec (Sparse Recovery) for imputation, with the following properties: (1) The optimization models of SparRec, based on low-rank and low number of co-clusters of matrices, are different from current statistics methods. While our low-rank matrix completion (LRMC) model is similar to Mendel-Impute, our matrix co-clustering factorization (MCCF) model is completely new. (2) SparRec, as other matrix completion methods, is flexible to be applied to missing data imputation for large meta-analysis with different cohorts genotyped on different sets of SNPs, even when there is no reference panel. This kind of meta-analysis is very challenging for current statistics based methods. (3) SparRec has consistent performance and achieves high recovery accuracy even when the missing data rate is as high as 90%. Compared with Mendel-Impute, our low-rank based method achieves similar accuracy and efficiency, while the co-clustering based method has advantages in running time. The testing results show that SparRec has significant advantages and competitive performance over other state-of-the-art existing statistics methods including Beagle and fastPhase.

  17. Solvent-based self-healing approaches for fiber-reinforced composites

    NASA Astrophysics Data System (ADS)

    Jones, Amanda R.

    Damage in composite materials spans many length scales and is often difficult to detect or costly to repair. The incorporation of self-healing functionality in composite materials has the potential to greatly extend material lifetime and reliability. Although there has been remarkable progress in self-healing polymers over the past decade, self-repair in fiber-reinforced composite materials presents significant technical challenges due to stringent manufacturing and performance requirements. For high performance, fiber-reinforced composites, the self-healing components need to survive high temperature processing, reside in matrix interstitial regions to retain a high fiber volume fraction, and have minimal impact on the mechanical properties of the host material. This dissertation explores several microencapsulated solvent-based self-healing approaches for fiber-reinforced composites at the fiber/ matrix interface size scale as well as matrix cracking. Systems are initially developed for room temperature cured epoxies/ glass fiber interfaces and successfully transitioned to carbon fibers and high temperature-cured, thermoplastic-toughened matrices. Full recovery of interfacial bond strength after complete fiber/matrix debonding is achieved with a microencapsulated solvent-based healing chemistry. The surface of a glass fiber is functionalized with microcapsules containing varying concentrations of reactive epoxy resin and ethyl phenyl acetate (EPA) solvent. Microbond specimens consisting of a single fiber and a microdroplet of epoxy are cured at 35°C, tested, and the interfacial shear strengths (IFSS) during the initial (virgin) debonding and subsequent healing events are measured. Debonding of the fiber/matrix interface ruptures the capsules, releasing resin and solvent into the crack plane. The solvent swells the matrix, initiating transport of residual amine functionality for further curing with the epoxy resin delivered to the crack plane. Using a resin-solvent ratio of 3:97, a maximum of 100% IFSS recovery is achieved-- a significant enhancement over prior work that reported 44% average recovery of IFSS with microencapsulated dicyclopentadiene (DCPD) monomer and Grubbs' 1st Generation catalyst healing agents. The effects of capsule coverage, resin-solvent ratio, and capsule size on recovery of IFSS are also determined, providing guidelines for integration of this healing system into high fiber volume fraction structural composites. High healing efficiencies are achieved with capsules as small as 0.6 mum average diameter. The resin-solvent healing system is then extended to repair of a carbon fiber/epoxy interfacial bond. A binder is necessary to improve the retention of capsules on the carbon fiber surface. Two different methods for applying a binder to a carbon fiber surface are investigated. Healing efficiency is assessed by recovery of IFSS of a single functionalized fiber embedded in an epoxy microbond specimen. The two binder protocols produce comparable results, both yielding higher recovery of IFSS than samples prepared without a binder. A maximum of 91% recovery of IFSS is achieved. In the next study, the resin-solvent healing system is applied to both interfacial damage and matrix cracking in a model composite specimen, consisting of discrete fiber tows embedded in a room temperature cured epoxy. Glass fiber tows are precisely placed in a compact tension specimen for controlled crack growth. The progression of matrix cracking and fiber debonding is observed optically during testing. Healing potential is assessed by injection of the healing agents into reference specimens (no capsules). The area under the load-displacement curve recovered during the healing event serves as a metric for evaluation of healing performance. Though full recovery is achieved in neat epoxy specimens, healing efficiency in multi-tow specimens is limited to 50%, due to the larger crack separations and energy lost during fiber fracture. In the case of only a singular embedded fiber tow, healing efficiency increases to an average of 83% recovery with full recovery in several samples. Additionally, microcapsules are incorporated into the compact tension specimen and along the fiber tow interface to evaluate in situ healing. Several strategies to improve microcapsule thermal stability are investigated in order to transition solvent-based healing to high temperature cured material systems. A double shell wall technique is adopted for several different size scales of microcapsules. First, the effect of the inner polyurethane (PU) shell wall thickness on thermal stability is evaluated. Though high thermal stability at 180°C is achieved for large (ca. 150 mum in diameter) capsules, smaller capsules (> 2 mum in diameter) suffer from increased core loss. The addition of certain core thickeners improves thermal stability for small capsules (ca. 20% increase in core retention) when compared to capsules with solvent alone. However, an additional poly(dopamine) coating leads to the greatest improvement in thermal stability, with nearly full retention of the core solvent for all capsule size scales. Finally, a thermoplastic resin poly(bisphenol A-co-epichlorohydrin), PBAE, is blended with a high glass transition temperature (Tg) epoxy matrix to simultaneously toughen and act as a healing agent in combination with encapsulated solvents. Microcapsules are coated with poly(dopamine) to improve the thermal stability and retain the core solvent during a cure cycle at 180°C. The fracture toughness of the high Tg epoxy (EPON 828: diamino diphenyl sulfone) is doubled by the addition of 20 wt % PBAE alone and tripled by the addition of both microcapsules and the thermoplastic phase. Self-healing is achieved with up to 57% recovery of fracture toughness of the toughened epoxy. Healing performance and fracture toughness of the microcapsule containing material remain stable after aging 30 days. The relative amounts of thermoplastic phase and the presence of solvent-filled microcapsules influence the storage modulus, Tg, and healing performance of the polymer.

  18. Planar solid phase extraction clean-up for pesticide residue analysis in tea by liquid chromatography-mass spectrometry.

    PubMed

    Oellig, Claudia; Schwack, Wolfgang

    2012-10-19

    Efficient clean-up is indispensable for preventing matrix effects in multi-residue analysis of pesticides in food by liquid and gas chromatography (LC and GC) coupled to mass spectrometry (MS). High-throughput planar solid phase extraction (HTpSPE) was recently introduced as a new clean-up concept in residue analysis of pesticides in fruit and vegetables (C. Oellig, W. Schwack, 2011 [45]). Thin-layer chromatography (TLC) was used to completely separate pesticides from matrix compounds and to focus them into a sharp zone, followed by extraction of the target zone by the TLC-MS interface. As rather challenging matrices, tea samples were chosen in this study. Besides chlorophylls and polyphenols, high amount of caffeine is co-extracted resulting in strong matrix effects both in LC-MS and GC-MS. The former HTpSPE procedure was adapted to initial extracts of green and black tea resulting in colorless extracts nearly free of matrix effects and interferences, as shown for seven chemically representative pesticides (acetamiprid, penconazole, azoxystrobin, chlorpyrifos, pirimicarb, fenarimol, and mepanipyrim). LC-MS/MS calibration curves obtained in the range of 0.002-0.5 mg/kg from matrix-matched standards and solvent standards were nearly identical and demonstrated the effectiveness of clean-up by HTpSPE. Mean recoveries determined by LC-MS/MS against solvent standards at spiking levels of 0.01 and 0.1 mg/kg ranged between 72 and 114% with relative standard deviations (RSDs) of 0.7-4.7% (n=4), while LC-MS measurements of tea samples spiked at 1 mg/kg provided recoveries of 81-104% with RSDs of 1.2-4.9% (n=6). Using LC-MS/MS, the method showed high sensitivity with signal-to-noise ratios>10 for concentrations below 0.002 mg/kg. HTpSPE of one sample was done in a few minutes, while numerous samples were cleaned in parallel at minimal costs with very low sample and solvent consumption. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. Determination of patulin in apple and derived products by UHPLC-MS/MS. Study of matrix effects with atmospheric pressure ionisation sources.

    PubMed

    Beltrán, Eduardo; Ibáñez, María; Sancho, Juan Vicente; Hernández, Félix

    2014-01-01

    Sensitive and reliable analytical methodology has been developed for the measurement of patulin in regulated foodstuffs by using ultra-high-performance liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS) with triple quadrupole analyser. Solid samples were extracted with ethyl acetate, while liquid samples were directly injected into the chromatographic system after dilution and filtration without any clean-up step. Chromatographic separation was achieved in less than 4min. Electrospray (ESI) and atmospheric pressure chemical ionisation (APCI) sources were evaluated, in order to assess matrix effects. The use of ESI source caused strong signal suppression in samples; however, matrix effect was negligible using APCI, allowing quantification with calibration standards prepared in solvent. The method was validated in four different apple matrices (juice, fruit, puree and compote) at two concentrations at the low μgkg(-1) level. Average recoveries (n=5) ranged from 71% to 108%, with RSDs lower than 14%. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Multimodal Deep Autoencoder for Human Pose Recovery.

    PubMed

    Hong, Chaoqun; Yu, Jun; Wan, Jian; Tao, Dacheng; Wang, Meng

    2015-12-01

    Video-based human pose recovery is usually conducted by retrieving relevant poses using image features. In the retrieving process, the mapping between 2D images and 3D poses is assumed to be linear in most of the traditional methods. However, their relationships are inherently non-linear, which limits recovery performance of these methods. In this paper, we propose a novel pose recovery method using non-linear mapping with multi-layered deep neural network. It is based on feature extraction with multimodal fusion and back-propagation deep learning. In multimodal fusion, we construct hypergraph Laplacian with low-rank representation. In this way, we obtain a unified feature description by standard eigen-decomposition of the hypergraph Laplacian matrix. In back-propagation deep learning, we learn a non-linear mapping from 2D images to 3D poses with parameter fine-tuning. The experimental results on three data sets show that the recovery error has been reduced by 20%-25%, which demonstrates the effectiveness of the proposed method.

  1. Immunochemical analytical methods for the determination of peanut proteins in foods.

    PubMed

    Whitaker, Thomas B; Williams, Kristina M; Trucksess, Mary W; Slate, Andrew B

    2005-01-01

    Peanut proteins can cause allergenic reactions that can result in respiratory and circulatory effects in the body sometimes leading to shock and death. The determination of peanut proteins in foods by analytical methods can reduce the risk of serious reactions in the highly sensitized individual by allowing for the detection of these proteins in a food at various stages of the manufacturing process. The method performance of 4 commercially available enzyme-linked immunosorbent assay (ELISA) kits was evaluated for the detection of peanut proteins in milk chocolate, ice cream, cookies, and breakfast cereals: ELISA-TEK Peanut Protein Assay, now known as "Bio-Kit" for peanut proteins, from ELISA Technologies Inc.; Veratox for Peanut Allergens from Neogen Corp.; RIDASCREEN Peanut Kit from R-Biopharm GmbH; and ProLisa from Canadian Food Technology Ltd. The 4 test kits were evaluated for accuracy (recovery) and precision using known concentrations of peanut or peanut proteins in the 4 food matrixes. Two different techniques, incurred and spiked, were used to prepare samples with 4 known concentrations of peanut protein. Defatted peanut flour was added in the incurred samples, and water-soluble peanut proteins were added in the spiked samples. The incurred levels were 0.0, 10, 20, and 100 microg whole peanut per g food; the spiked levels were 0.0, 5, 10, and 20 microg peanut protein per g food. Performance varied by test kit, protein concentration, and food matrix. The Veratox kit had the best accuracy or lowest percent difference between measured and incurred levels of 15.7% when averaged across all incurred levels and food matrixes. Recoveries associated with the Veratox kit varied from 93 to 115% for all food matrixes except cookies. Recoveries for all kits were about 50% for cookies. The analytical precision, as measured by the variance, increased with an increase in protein concentration. However, the coefficient of variation (CV) was stable across the 4 incurred protein levels and was 7.0% when averaged across the 4 food matrixes and analytical kits. The R-Biopharm test kit had the best precision or a CV of 4.2% when averaged across all incurred levels and food matrixes. Because measured protein values varied by test kit and food matrix, a method was developed to normalize or transform measured protein concentrations to an adjusted protein value that was equal to the known protein concentration. The normalization method adjusts measured protein values to equal the true protein value regardless of the type test kit or type food matrix.

  2. Characteristic Fracture Spacing in Primary and Secondary Recovery from Naturally Fractured Reservoirs

    NASA Astrophysics Data System (ADS)

    Gong, J.; Rossen, W.

    2015-12-01

    We showed previously (Gong and Rossen, 2014a,b) that, if the fracture aperture distribution is broad enough in a naturally fractured reservoir, even one where the fracture network is well-connected, most fractures can be eliminated without significantly affecting the flow through the fracture network. During a waterflood or enhanced-oil-recovery (EOR) process, the production of oil depends on the supply of injected water or EOR agent. This suggests that the characteristic fracture spacing for the dual-porosity/dual-permeability simulation of waterflood or EOR in a naturally fractured reservoir should account not for all fractures but only the relatively small portion of the fracture network carrying almost all the injected water or EOR agent. In contrast, in primary production even a relatively small fracture represents an effective path for oil to flow to a production well. Thus in primary production the effective fracture spacing should include all the fractures. This distinction means that the "shape factor" in dual-porosity/dual-permeability reservoir simulators and the repeating unit in homogenization should depend on the process involved: specifically, it should be different for primary and secondary or tertiary recovery. We test this hypothesis in a simple representation of a fractured reservoir with a non-uniform distribution of fracture flow conductivities. We compare oil production, flow patterns in matrix, and the pattern of oil recovery around fractures with and without the "unimportant" fractures present. In primary production, all fractures which are much more permeable than matrix play a significant role in production. The shape factor or repeating-unit size should reflect the entire fracture distribution. In secondary or tertiary production, the role of fractures that carry relatively little flow depends on injection rate, the ratio of flow carried by the different fractures, and the permeability of matrix. In some cases, the appropriate shape factor or repeating-unit size for waterflood or EOR should reflect only those fractures that carry most of the flow. References:Gong, and Rossen, 14th ECMOR Conf., Catania, Sicily, 2014(a). Gong, and Rossen, Intl. Discrete Fracture Network Eng. Conf., Vancouver, Canada, 2014(b).

  3. A strategy for prioritizing threats and recovery actions for at-risk species.

    PubMed

    Darst, Catherine R; Murphy, Philip J; Strout, Nathan W; Campbell, Steven P; Field, Kimberleigh J; Allison, Linda; Averill-Murray, Roy C

    2013-03-01

    Ensuring the persistence of at-risk species depends on implementing conservation actions that ameliorate threats. We developed and implemented a method to quantify the relative importance of threats and to prioritize recovery actions based on their potential to affect risk to Mojave desert tortoises (Gopherus agassizii). We used assessments of threat importance and elasticities of demographic rates from population matrix models to estimate the relative contributions of threats to overall increase in risk to the population. We found that urbanization, human access, military operations, disease, and illegal use of off highway vehicles are the most serious threats to the desert tortoise range-wide. These results suggest that, overall, recovery actions that decrease habitat loss, predation, and crushing will be most effective for recovery; specifically, we found that habitat restoration, topic-specific environmental education, and land acquisition are most likely to result in the greatest decrease in risk to the desert tortoise across its range. In addition, we have developed an application that manages the conceptual model and all supporting information and calculates threat severity and potential effectiveness of recovery actions. Our analytical approach provides an objective process for quantifying threats, prioritizing recovery actions, and developing monitoring metrics for those actions for adaptive management of any at-risk species.

  4. Processing and damage recovery of intrinsic self-healing glass fiber reinforced composites

    NASA Astrophysics Data System (ADS)

    Sordo, Federica; Michaud, Véronique

    2016-08-01

    Glass fiber reinforced composites with a self-healing, supramolecular hybrid network matrix were produced using a modified vacuum assisted resin infusion moulding process adapted to high temperature processing. The quality and fiber volume fraction (50%) of the obtained materials were assessed through microscopy and matrix burn-off methods. The thermo-mechanical properties were quantified by means of dynamic mechanical analysis, revealing very high damping properties compared to traditional epoxy-based glass fiber reinforced composites. Self-healing properties were assessed by three-point bending tests. A high recovery of the flexural properties, around 72% for the elastic modulus and 65% of the maximum flexural stress, was achieved after a resting period of 24 h at room temperature. Recovery after low velocity impact events was also visually observed. Applications for this intrinsic and autonomic self-healing highly reinforced composite material point towards semi-structural applications where high damping and/or integrity recovery after impact are required.

  5. Efficient Tensor Completion for Color Image and Video Recovery: Low-Rank Tensor Train.

    PubMed

    Bengua, Johann A; Phien, Ho N; Tuan, Hoang Duong; Do, Minh N

    2017-05-01

    This paper proposes a novel approach to tensor completion, which recovers missing entries of data represented by tensors. The approach is based on the tensor train (TT) rank, which is able to capture hidden information from tensors thanks to its definition from a well-balanced matricization scheme. Accordingly, new optimization formulations for tensor completion are proposed as well as two new algorithms for their solution. The first one called simple low-rank tensor completion via TT (SiLRTC-TT) is intimately related to minimizing a nuclear norm based on TT rank. The second one is from a multilinear matrix factorization model to approximate the TT rank of a tensor, and is called tensor completion by parallel matrix factorization via TT (TMac-TT). A tensor augmentation scheme of transforming a low-order tensor to higher orders is also proposed to enhance the effectiveness of SiLRTC-TT and TMac-TT. Simulation results for color image and video recovery show the clear advantage of our method over all other methods.

  6. Matrix-elimination with steam distillation for determination of short-chain fatty acids in hypersaline waters from pre-salt layer by ion-exclusion chromatography.

    PubMed

    Ferreira, Fernanda N; Carneiro, Manuel C; Vaitsman, Delmo S; Pontes, Fernanda V M; Monteiro, Maria Inês C; Silva, Lílian Irene D da; Neto, Arnaldo Alcover

    2012-02-03

    A method for determination of formic, acetic, propionic and butyric acids in hypersaline waters by ion-exclusion chromatography (IEC), using steam distillation to eliminate matrix-interference, was developed. The steam distillation variables such as type of solution to collect the distillate, distillation time and volume of the 50% v/v H₂SO₄ solution were optimized. The effect of the addition of NaCl different concentrations to the calibration standards on the carboxylic acid recovery was also investigated. Detection limits of 0.2, 0.5, 0.3 and 1.5 mg L⁻¹ were obtained for formic, acetic, propionic and butyric acids, respectively. Produced waters from petroleum reservoirs in the Brazilian pre-salt layer containing about 19% m/v of NaCl were analyzed. Good recoveries (99-108%) were obtained for all acids in spiked produced water samples. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. Utilization of agro-industrial waste for biosurfactant production under submerged fermentation and its application in oil recovery from sand matrix.

    PubMed

    Das, Amar Jyoti; Kumar, Rajesh

    2018-07-01

    This study reports biosurfactant production by Pseudomonas azotoformans AJ15 under submerged fermentation via utilizing the agro-industrial wastes (bagasse and potato peels). The extracted biosurfactant was characterized for its classification (nature, group, and class) and stability against environmental stresses. Further, the biosurfactant was employed to explore its oil recovery efficiency from the sand matrix with 2000 ppm salt concentration. Results revealed that substrates developed by mixing both the agro-industrial wastes account for high yield of biosurfactant. The subsequent experimental studies demonstrated that the biosurfactant might belong to glycolipid group and rhamnolipid class. Moreover, the biosurfactant was stable at a high temperature of 90 °C and enable to persist its activity in the high salt concentration of 6% and varying pH. The biosurfactant was found to be effective in recovering up to 36.56% of trapped oil under saline condition. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. Functioned silver nanoparticle loaded activated carbon for the recovery of bioactive molecule from bacterial fermenter for its bactericidal activity

    NASA Astrophysics Data System (ADS)

    Arivizhivendhan, Villalan; Mahesh, Mannacharaju; Boopathy, Ramasamy; Karthikeyan, Sekar; Mary, Rathanasamy Regina; Sekaran, Ganesan

    2018-01-01

    A novel continuous production and extraction of bacterial bioactive prodigiosin (PG) from fermented using silver nanoparticle impregnated functioned activated carbon composite is proposed for cost-effective and ecofriendly microbial technique. Hence, in this investigation silver nanoparticle was impregnated onto functioned activated carbon ([AC]F) as a support matrix and to enable the separation of PG conjugated silver nanoparticle from the fermented medium. A laboratory scale experiment was carried out to evaluate the continuous production and recovery of PG using [AC@Ag]F. Ag nanoparticle impregnated [AC]F ([AC@Ag]F) characterized by FT-IR, XRD, TGA, DSC and SEM. Instrumental analyses confirmed that Ag nanoparticles significantly impregnated on AC through the functionalization of AC with diethanolamine and it enhances the binding capacity between AC and Ag. The various process parameters, such as contact time, pH, and mass of [AC@Ag]F, were statistically optimized for the recovery of PG using Response Surface Methodology (RSM). The maximum extraction of PG in [AC@Ag]F was found to be 16.2 ± 0.2 mg g-1, its twofold higher than [AC]F. Further, PG conjugated [AC@Ag]F and ([AC@Ag]F-PG) were checked for the growth inhibition of gram negative and gram positive bacteria without formation of biofilm upto 96 h. Hence, the developed matrix could be eco-friendly, viable and lower energy consumption step for separation of the bacterial bioactive PG from fermented broth. In additionally, [AC@Ag]F-PG was used as an antifouling matrix without formation of biofilm.

  9. Evaluation of a recent product to remove lipids and other matrix co-extractives in the analysis of pesticide residues and environmental contaminants in foods.

    PubMed

    Han, Lijun; Matarrita, Jessie; Sapozhnikova, Yelena; Lehotay, Steven J

    2016-06-03

    This study demonstrates the application of a novel lipid removal product to the residue analysis of 65 pesticides and 52 environmental contaminants in kale, pork, salmon, and avocado by fast, low pressure gas chromatography - tandem mass spectrometry (LPGC-MS/MS). Sample preparation involves QuEChERS extraction followed by use of EMR-Lipid ("enhanced matrix removal of lipids") and an additional salting out step for cleanup. The optimal amount of EMR-Lipid was determined to be 500mg for 2.5mL extracts for most of the analytes. The co-extractive removal efficiency by the EMR-Lipid cleanup step was 83-98% for fatty samples and 79% for kale, including 76% removal of chlorophyll. Matrix effects were typically less than ±20%, in part because analyte protectants were used in the LPGC-MS/MS analysis. The recoveries of polycyclic aromatic hydrocarbons and diverse pesticides were mostly 70-120%, whereas recoveries of nonpolar polybrominated diphenyl ethers and polychlorinated biphenyls were mostly lower than 70% through the cleanup procedure. With the use of internal standards, method validation results showed that 76-85 of the 117 analytes achieved satisfactory results (recoveries of 70-120% and RSD≤20%) in pork, avocado, and kale, while 53 analytes had satisfactory results in salmon. Detection limits were 5-10ng/g for all but a few analytes. EMR-Lipid is a new sample preparation tool that serves as another useful option for cleanup in multiresidue analysis, particularly of fatty foods. Published by Elsevier B.V.

  10. Orthogonal Comparison of GC-MS and 1H NMR Spectroscopy for Short Chain Fatty Acid Quantitation.

    PubMed

    Cai, Jingwei; Zhang, Jingtao; Tian, Yuan; Zhang, Limin; Hatzakis, Emmanuel; Krausz, Kristopher W; Smith, Philip B; Gonzalez, Frank J; Patterson, Andrew D

    2017-08-01

    Short chain fatty acids (SCFAs) are important regulators of host physiology and metabolism and may contribute to obesity and associated metabolic diseases. Interest in SCFAs has increased in part due to the recognized importance of how production of SCFAs by the microbiota may signal to the host. Therefore, reliable, reproducible, and affordable methods for SCFA profiling are required for accurate identification and quantitation. In the current study, four different methods for SCFA (acetic acid, propionic acid, and butyric acid) extraction and quantitation were compared using two independent platforms including gas chromatography coupled with mass spectrometry (GC-MS) and 1 H nuclear magnetic resonance (NMR) spectroscopy. Sensitivity, recovery, repeatability, matrix effect, and validation using mouse fecal samples were determined across all methods. The GC-MS propyl esterification method exhibited superior sensitivity for acetic acid and butyric acid measurement (LOD < 0.01 μg mL -1 , LOQ < 0.1 μg mL -1 ) and recovery accuracy (99.4%-108.3% recovery rate for 100 μg mL -1 SCFA mixed standard spike in and 97.8%-101.8% recovery rate for 250 μg mL -1 SCFAs mixed standard spike in). NMR methods by either quantitation relative to an internal standard or quantitation using a calibration curve yielded better repeatability and minimal matrix effects compared to GC-MS methods. All methods generated good calibration curve linearity (R 2 > 0.99) and comparable measurement of fecal SCFA concentration. Lastly, these methods were used to quantitate fecal SCFAs obtained from conventionally raised (CONV-R) and germ free (GF) mice. Results from global metabolomic analysis of feces generated by 1 H NMR and bomb calorimetry were used to further validate these approaches.

  11. An Efficient Semi-fragile Watermarking Scheme for Tamper Localization and Recovery

    NASA Astrophysics Data System (ADS)

    Hou, Xiang; Yang, Hui; Min, Lianquan

    2018-03-01

    To solve the problem that remote sensing images are vulnerable to be tampered, a semi-fragile watermarking scheme was proposed. Binary random matrix was used as the authentication watermark, which was embedded by quantizing the maximum absolute value of directional sub-bands coefficients. The average gray level of every non-overlapping 4×4 block was adopted as the recovery watermark, which was embedded in the least significant bit. Watermarking detection could be done directly without resorting to the original images. Experimental results showed our method was robust against rational distortions to a certain extent. At the same time, it was fragile to malicious manipulation, and realized accurate localization and approximate recovery of the tampered regions. Therefore, this scheme can protect the security of remote sensing image effectively.

  12. Characterization and modeling of three-dimensional self-healing shape memory alloy-reinforced metal-matrix composites

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhu, Pingping; Cui, Zhiwei; Kesler, Michael S.

    In this paper, three-dimensional metal-matrix composites (MMCs) reinforced by shape memory alloy (SMA) wires are modeled and simulated, by adopting an SMA constitutive model accounting for elastic deformation, phase transformation and plastic behavior. A modeling method to create composites with pre-strained SMA wires is also proposed to improve the self-healing ability. Experimental validation is provided with a composite under three-point bending. This modeling method is applied in a series of finite element simulations to investigate the self-healing effects in pre-cracked composites, especially the role of the SMA reinforcement, the softening property of the matrix, and the effect of pre-strain inmore » the SMA. The results demonstrate that SMA reinforcements provide stronger shape recovery ability than other, non-transforming materials. The softening property of the metallic matrix and the pre-strain in SMA are also beneficial to help crack closure and healing. This modeling approach can serve as an efficient tool to design SMA-reinforced MMCs with optimal self-healing properties that have potential applications in components needing a high level of reliability.« less

  13. Multiresidue analysis of multiclass pesticides and polyaromatic hydrocarbons in fatty fish by gas chromatography tandem mass spectrometry and evaluation of matrix effect.

    PubMed

    Chatterjee, Niladri S; Utture, Sagar; Banerjee, Kaushik; Ahammed Shabeer, T P; Kamble, Narayan; Mathew, Suseela; Ashok Kumar, K

    2016-04-01

    This paper reports a selective and sensitive method for multiresidue determination of 119 chemical residues including pesticides and polyaromatic hydrocarbons (PAH) in high fatty fish matrix. The novel sample preparation method involved extraction of the target analytes from homogenized fish meat (5 g) in acetonitrile (15 mL, 1% acetic acid) after three-phase partitioning with hexane (2 mL) and the remaining aqueous layer. An aliquot (1.5 mL) of the acetonitrile layer was aspirated and subjected to two-stage dispersive solid phase extraction (dSPE) cleanup and the residues were finally estimated by gas chromatography mass spectrometry with selected reaction monitoring (GC-MS/MS). The co-eluted matrix components were identified on the basis of their accurate mass by GC with quadrupole time of flight MS. Addition of hexane during extraction and optimized dSPE cleanup significantly minimized the matrix effects. Recoveries at 10, 25 and 50 μg/kg were within 60-120% with associated precision, RSD<11%. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Nuclear decontamination technology evaluation to address contamination of a municipal water system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McFee, J.; Langsted, J.; Young, M.

    The US Environmental Protection Agency (EPA) and US Department of Homeland Security (DHS) are considering the impact and recovery from contamination of municipal water systems, including intentional contamination of those systems. Industrial chemicals, biological agents, drugs, pesticides, chemical warfare agents, and radionuclides all could be introduced into a municipal water system to create detrimental health effects and disrupt a community. Although unintentional, the 1993 cryptosporidium contamination of the Milwaukee WS water system resulted in 100 fatalities and disrupted the city for weeks. Shaw Environmental and Infrastructure Inc, (Shaw), as a subcontractor on a DHS contract with Michael Baker Jr., Inc.,more » was responsible for evaluation of the impact and recovery from radionuclide contamination in a municipal water system distribution system. Shaw was tasked to develop a matrix of nuclear industry decontamination technologies and evaluate applicability to municipal water systems. Shaw expanded the evaluation to include decontamination methods commonly used in the drinking water supply. The matrix compared all technologies for implementability, effectiveness, and cost. To address the very broad range of contaminants and contamination scenarios, Shaw bounded the problem by identification of specific contaminant release scenario(s) for specific water system architecture(s). A decontamination technology matrix was developed containing fifty-nine decontamination technologies potentially applicable to the water distribution system piping, pumps, tanks, associated equipment, and/or contaminated water. Qualitatively, the majority of the nuclear industry decontamination technologies were eliminated from consideration due to implementability concerns. However, inclusion of the municipal water system technologies supported recommendations that combined the most effective approaches in both industries. (authors)« less

  15. Multi-layer solid-phase extraction and evaporation-enrichment methods for polar organic chemicals from aqueous matrices.

    PubMed

    Köke, Niklas; Zahn, Daniel; Knepper, Thomas P; Frömel, Tobias

    2018-03-01

    Analysis of polar organic chemicals in the aquatic environment is exacerbated by the lack of suitable and widely applicable enrichment methods. In this work, we assessed the suitability of a novel combination of well-known solid-phase extraction (SPE) materials in one cartridge as well as an evaporation method and for the enrichment of 26 polar model substances (predominantly log D < 0) covering a broad range of physico-chemical properties in three different aqueous matrices. The multi-layer solid-phase extraction (mlSPE) and evaporation method were investigated for the recovery and matrix effects of the model substances and analyzed with hydrophilic interaction liquid chromatography-tandem mass spectrometry (HILIC-MS/MS). In total, 65% of the model substances were amenable (> 10% recovery) to the mlSPE method with a mean recovery of 76% while 73% of the model substances were enriched with the evaporation method achieving a mean recovery of 78%. Target and non-target screening comparison of both methods with a frequently used reversed-phase SPE method utilizing "hydrophilic and lipophilic balanced" (HLB) material was performed. Target analysis showed that the mlSPE and evaporation method have pronounced advantages over the HLB method since the HLB material retained only 30% of the model substances. Non-target screening of a ground water sample with the investigated enrichment methods showed that the median retention time of all detected features on a HILIC system decreased in the order mlSPE (3641 features, median t R 9.7 min), evaporation (1391, 9.3 min), HLB (4414, 7.2 min), indicating a higher potential of the described methods to enrich polar analytes from water compared with HLB-SPE. Graphical abstract Schematic of the method evaluation (recovery and matrix effects) and method comparison (target and non-target analysis) of the two investigated enrichment methods for very polar chemicals in aqueousmatrices.

  16. Determination of perfluorinated carboxylic acids in fish fillet by micro-solid phase extraction, followed by liquid chromatography-triple quadrupole mass spectrometry.

    PubMed

    Lashgari, Maryam; Lee, Hian Kee

    2014-11-21

    In the current study, a simple, fast and efficient combination of protein precipitation and micro-solid phase extraction (μ-SPE) followed by liquid chromatography-triple quadrupole tandem mass spectrometry (LC-MS/MS) was developed for the determination of perfluorinated carboxylic acids (PFCAs) in fish fillet. Ten PFCAs with different hydrocarbon chain lengths (C5-C14) were analysed simultaneously using this method. Protein precipitation by acetonitrile and μ-SPE by surfactant-incorporated ordered mesoporous silica were applied to the extraction and concentration of the PFCAs as well as for removal of interferences. Determination of the PFCAs was carried out by LC-MS/MS in negative electrospray ionization mode. MS/MS parameters were optimized for multiple reaction monitoring of the analytes. (13)C mass labelled PFOA as a stable-isotopic internal standard, was used for calibration. The detection limits of the method ranged from 0.97 ng/g to 2.7 ng/g, with a relative standard deviation of between 5.4 and 13.5. The recoveries were evaluated for each analyte and were ranged from 77% to 120%. The t-test at 95% confidence level showed that for all the analytes, the relative recoveries did not depend on their concentrations in the explored concentration range. The effect of the matrix on MS signals (suppression or enhancement) was also evaluated. Contamination at low levels was detected for some analytes in the fish samples. The protective role of the polypropylene membrane used in μ-SPE in the elimination of matrix effects was evaluated by parallel experiments in classical dispersive solid phase extraction. The results evidently showed that the polypropylene membrane was significantly effective in reducing matrix effects. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Using color histogram normalization for recovering chromatic illumination-changed images.

    PubMed

    Pei, S C; Tseng, C L; Wu, C C

    2001-11-01

    We propose a novel image-recovery method using the covariance matrix of the red-green-blue (R-G-B) color histogram and tensor theories. The image-recovery method is called the color histogram normalization algorithm. It is known that the color histograms of an image taken under varied illuminations are related by a general affine transformation of the R-G-B coordinates when the illumination is changed. We propose a simplified affine model for application with illumination variation. This simplified affine model considers the effects of only three basic forms of distortion: translation, scaling, and rotation. According to this principle, we can estimate the affine transformation matrix necessary to recover images whose color distributions are varied as a result of illumination changes. We compare the normalized color histogram of the standard image with that of the tested image. By performing some operations of simple linear algebra, we can estimate the matrix of the affine transformation between two images under different illuminations. To demonstrate the performance of the proposed algorithm, we divide the experiments into two parts: computer-simulated images and real images corresponding to illumination changes. Simulation results show that the proposed algorithm is effective for both types of images. We also explain the noise-sensitive skew-rotation estimation that exists in the general affine model and demonstrate that the proposed simplified affine model without the use of skew rotation is better than the general affine model for such applications.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alhajeri, Saleh N., E-mail: sn.alhajeri@paaet.edu.

    Disks of an Al-6061 metal matrix composite, reinforced with 10 vol.% Al{sub 2}O{sub 3} particles, were processed by high-pressure torsion (HPT) at room temperature for 1/4, 1/2, 1, 5 and 10 turns under an applied pressure of 6.0 GPa. The evolution of microstructure was investigated using optical microscopy and scanning electron microscopy. During HPT processing the average grain size within the aluminum matrix decreased from ∼ 35 μm in the unprocessed condition to ∼ 170 nm after processing through 10 turns but there was no significant effect on the size and distribution of the alumina particulate clusters. The values ofmore » the Vickers microhardness were recorded across the surface of each disk and then plotted as two-dimensional and three-dimensional color-coded contour maps. The results show the hardness increases from ∼ 56 Hv in the initial condition to ∼ 165 Hv after HPT for 10 turns. The results demonstrate that, as in many unreinforced metallic alloys, the evolution of hardness with strain exhibits strain hardening without any significant recovery. - Highlights: •The average grain size of the Al matrix was ~ 170 nm after processing for 10 turns. •No significant effect of HPT on the size and distribution of the Al{sub 2}O{sub 3} particles. •The evolution of microhardness demonstrates strain hardening without recovery. •The microhardness at low strains increases linearly from the center to the edge. •The microhardness at high strains becomes homogeneous with a saturation of ~ 170 Hv.« less

  19. COMPARISONS OF SOXHLET EXTRACTION, PRESSURIZED LIQUID EXTRACTION, SUPERCRITICAL FLUID EXTRACTION, AND SUBCRITICAL WATER EXTRACTION FOR ENVIRONMENTAL SOLIDS: RECOVERY, SELECTIVITY, AND EFFECTS ON SAMPLE MATRIX. (R825394)

    EPA Science Inventory

    Extractions of a polycyclic aromatic hydrocarbon (PAH)-contaminated soil from a former manufactured gas plant site were performed with a Soxhlet apparatus (18 h), by pressurized liquid extraction (PLE) (50 min at 100°C), supercritical fluid extraction (SFE) (1 h at 150°...

  20. Adipose-derived mesenchymal stem cells accelerate nerve regeneration and functional recovery in a rat model of recurrent laryngeal nerve injury.

    PubMed

    Li, Yun; Xu, Wen; Cheng, Li-Yu

    2017-09-01

    Medialization thyroplasty or injection laryngoplasty for unilateral vocal fold paralysis cannot restore mobility of the vocal fold. Recent studies have shown that transplantation of mesenchymal stem cells is effective in the repair of nerve injuries. This study investigated whether adipose-derived stem cell transplantation could repair recurrent laryngeal nerve injury. Rat models of recurrent laryngeal nerve injury were established by crushing with micro forceps. Adipose-derived mesenchymal stem cells (ADSCs; 8 × 10 5 ) or differentiated Schwann-like adipose-derived mesenchymal stem cells (dADSCs; 8 × 10 5 ) or extracellular matrix were injected at the site of injury. At 2, 4 and 6 weeks post-surgery, a higher density of myelinated nerve fiber, thicker myelin sheath, improved vocal fold movement, better recovery of nerve conduction capacity and reduced thyroarytenoid muscle atrophy were found in ADSCs and dADSCs groups compared with the extracellular matrix group. The effects were more pronounced in the ADSCs group than in the dADSCs group. These experimental results indicated that ADSCs transplantation could be an early interventional strategy to promote regeneration after recurrent laryngeal nerve injury.

  1. Factors influencing the extraction of pharmaceuticals from sewage sludge and soil: an experimental design approach.

    PubMed

    Ferhi, Sabrina; Bourdat-Deschamps, Marjolaine; Daudin, Jean-Jacques; Houot, Sabine; Nélieu, Sylvie

    2016-09-01

    Pharmaceuticals can enter the environment when organic waste products are recycled on agricultural soils. The extraction of pharmaceuticals is a challenging step in their analysis. The very different extraction conditions proposed in the literature make the choice of the right method for multi-residue analysis difficult. This study aimed at evaluating, with experimental design methodology, the influence of the nature, pH and composition of the extraction medium on the extraction recovery of 14 pharmaceuticals, including 8 antibiotics, from soil and sewage sludge. Preliminary experimental designs showed that acetonitrile and citrate-phosphate buffer were the best extractants. Then, a response surface design demonstrated that many cross-product and squared terms had significant effects, explaining the shapes of the response surfaces. It also allowed optimising the pharmaceutical recoveries in soil and sludge. The optimal conditions were interpreted considering the ionisation states of the compounds, their solubility in the extraction medium and their interactions with the solid matrix. To perform the analysis, a compromise was made for each matrix. After a QuEChERS purification, the samples were analysed by online SPE-UHPLC-MS-MS. Both methods were simple and economical. They were validated with the accuracy profile methodology for soil and sludge and characterised for another type of soil, digested sludge and composted sludge. Trueness globally ranged between 80 and 120 % recovery, and inter- and intra-day precisions were globally below 20 % relative standard deviation. Various pharmaceuticals were present in environmental samples, with concentration levels ranging from a few micrograms per kilogramme up to thousands of micrograms per kilogramme. Graphical abstract Influence of the extraction medium on the extraction recovery of 14 pharmaceuticals. Influence of the ionisation state, the solubility and the interactions of pharmaceuticals with solid matrix. Analysis of different soils and organic waste products.

  2. In-situ formation of Ni4Ti3 precipitate and its effect on pseudoelasticity in selective laser melting additive manufactured NiTi-based composites

    NASA Astrophysics Data System (ADS)

    Gu, Dongdong; Ma, Chenglong

    2018-05-01

    Selective laser melting (SLM) additive manufacturing technology was applied to synthesize NiTi-based composites via using ball-milled Ti, Ni, and TiC mixed powder. By transmission electron microscope (TEM) characterization, it indicated that the B2 (NiTi) matrix was obtained during SLM processing. In spite of more Ti content (the Ti/Ni ratio >1), a mass of Ni-rich intermetallic compounds containing Ni4Ti3 with nanostructure features and eutectic Ni3Ti around in-situ Ti6C3.75 dendrites were precipitated. Influence of the applied laser volume energy density (VED) on the morphology and content of Ni4Ti3 precipitate was investigated. Besides, nanoindentation test of the matrix was performed in order to assess pseudoelastic recovery behavior of SLM processed NiTi-based composites. At a relatively high VED of 533 J/mm3, the maximum pseudoelastic recovery was obtained due to the lowest content of Ni4Ti3 precipitates. Furthermore, the precipitation mechanism of in-situ Ni4Ti3 was present based on the redistribution of titanium element and thermodynamics analysis, and then the relationship of Ni4Ti3 precipitate, VED and pseudoelastic recovery behavior was also revealed.

  3. Fast quantification of endogenous carbohydrates in plasma using hydrophilic interaction liquid chromatography coupled with tandem mass spectrometry.

    PubMed

    Zhu, Bangjie; Liu, Feng; Li, Xituo; Wang, Yan; Gu, Xue; Dai, Jieyu; Wang, Guiming; Cheng, Yu; Yan, Chao

    2015-01-01

    Endogenous carbohydrates in biosamples are frequently highlighted as the most differential metabolites in many metabolomics studies. A simple, fast, simultaneous quantitative method for 16 endogenous carbohydrates in plasma has been developed using hydrophilic interaction liquid chromatography coupled with tandem mass spectrometry. In order to quantify 16 endogenous carbohydrates in plasma, various conditions, including columns, chromatographic conditions, mass spectrometry conditions, and plasma preparation methods, were investigated. Different conditions in this quantified analysis were performed and optimized. The reproducibility, precision, recovery, matrix effect, and stability of the method were verified. The results indicated that a methanol/acetonitrile (50:50, v/v) mixture could effectively and reproducibly precipitate rat plasma proteins. Cold organic solvents coupled with vortex for 1 min and incubated at -20°C for 20 min were the most optimal conditions for protein precipitation and extraction. The results, according to the linearity, recovery, precision, matrix effect, and stability, showed that the method was satisfactory in the quantification of endogenous carbohydrates in rat plasma. The quantified analysis of endogenous carbohydrates in rat plasma performed excellently in terms of sensitivity, high throughput, and simple sample preparation, which met the requirement of quantification in specific expanded metabolomic studies after the global metabolic profiling research. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. 3D shape recovery from image focus using gray level co-occurrence matrix

    NASA Astrophysics Data System (ADS)

    Mahmood, Fahad; Munir, Umair; Mehmood, Fahad; Iqbal, Javaid

    2018-04-01

    Recovering a precise and accurate 3-D shape of the target object utilizing robust 3-D shape recovery algorithm is an ultimate objective of computer vision community. Focus measure algorithm plays an important role in this architecture which convert the color values of each pixel of the acquired 2-D image dataset into corresponding focus values. After convolving the focus measure filter with the input 2-D image dataset, a 3-D shape recovery approach is applied which will recover the depth map. In this document, we are concerned with proposing Gray Level Co-occurrence Matrix along with its statistical features for computing the focus information of the image dataset. The Gray Level Co-occurrence Matrix quantifies the texture present in the image using statistical features and then applies joint probability distributive function of the gray level pairs of the input image. Finally, we quantify the focus value of the input image using Gaussian Mixture Model. Due to its little computational complexity, sharp focus measure curve, robust to random noise sources and accuracy, it is considered as superior alternative to most of recently proposed 3-D shape recovery approaches. This algorithm is deeply investigated on real image sequences and synthetic image dataset. The efficiency of the proposed scheme is also compared with the state of art 3-D shape recovery approaches. Finally, by means of two global statistical measures, root mean square error and correlation, we claim that this approach -in spite of simplicity generates accurate results.

  5. Uniform Recovery Bounds for Structured Random Matrices in Corrupted Compressed Sensing

    NASA Astrophysics Data System (ADS)

    Zhang, Peng; Gan, Lu; Ling, Cong; Sun, Sumei

    2018-04-01

    We study the problem of recovering an $s$-sparse signal $\\mathbf{x}^{\\star}\\in\\mathbb{C}^n$ from corrupted measurements $\\mathbf{y} = \\mathbf{A}\\mathbf{x}^{\\star}+\\mathbf{z}^{\\star}+\\mathbf{w}$, where $\\mathbf{z}^{\\star}\\in\\mathbb{C}^m$ is a $k$-sparse corruption vector whose nonzero entries may be arbitrarily large and $\\mathbf{w}\\in\\mathbb{C}^m$ is a dense noise with bounded energy. The aim is to exactly and stably recover the sparse signal with tractable optimization programs. In this paper, we prove the uniform recovery guarantee of this problem for two classes of structured sensing matrices. The first class can be expressed as the product of a unit-norm tight frame (UTF), a random diagonal matrix and a bounded columnwise orthonormal matrix (e.g., partial random circulant matrix). When the UTF is bounded (i.e. $\\mu(\\mathbf{U})\\sim1/\\sqrt{m}$), we prove that with high probability, one can recover an $s$-sparse signal exactly and stably by $l_1$ minimization programs even if the measurements are corrupted by a sparse vector, provided $m = \\mathcal{O}(s \\log^2 s \\log^2 n)$ and the sparsity level $k$ of the corruption is a constant fraction of the total number of measurements. The second class considers randomly sub-sampled orthogonal matrix (e.g., random Fourier matrix). We prove the uniform recovery guarantee provided that the corruption is sparse on certain sparsifying domain. Numerous simulation results are also presented to verify and complement the theoretical results.

  6. CM352 Reduces Brain Damage and Improves Functional Recovery in a Rat Model of Intracerebral Hemorrhage.

    PubMed

    Rodríguez, José A; Sobrino, Tomás; López-Arias, Esteban; Ugarte, Ana; Sánchez-Arias, Juan A; Vieites-Prado, Alba; de Miguel, Irene; Oyarzabal, Julen; Páramo, José A; Campos, Francisco; Orbe, Josune; Castillo, José

    2017-06-01

    Intracerebral hemorrhage (ICH) is an acute neurological disorder with high mortality and no effective treatment. In addition to the initial bleeding event, rebleeding and hematoma expansion are associated with poor outcome in these patients. We studied the effectiveness of the new antifibrinolytic agent CM352, a short-half-life matrix metalloproteinase inhibitor, for achieving early hemostasis and improving functional recovery in a rat model of collagenase-induced ICH. ICH was induced by striatal injection of collagenase, and 1 hour later, rats received an intravenous injection of saline (n=6) or CM352 (1 mg/kg, n=6). Hematoma (basal and after 3 and 24 hours) and lesion (14 days) volumes were quantified on T2-weighted (T2) magnetic resonance images. Neurological and functional recovery was evaluated by using Bederson score and a cylinder test (basal, 24 hours, and 14 days). Early treatment (1 hour) with CM352 was efficient reducing hematoma expansion at 3 hours ( P <0.01) and, more markedly, at 24 hours ( P <0.01). Decreased bleeding after antifibrinolytic treatment was accompanied by reduced interleukin-6 levels at 3 hours ( P <0.05) and smaller lesion volume at 14 days ( P <0.01). CM352 drastically reduced sensorimotor impairment (cylinder test) after ICH in rats at 24 hours ( P <0.01) and 14 days ( P <0.01). Similarly, it also attenuated neurological deficit (Bederson scale) at 24 hours ( P <0.01) and 14 days ( P <0.01). Interestingly, late (3 hours) CM352 administration also resulted in reduced lesion size and better functional outcome. CM352, a new antifibrinolytic agent and matrix metalloproteinase inhibitor, effectively prevented hematoma growth and reduced lesion size in ICH in association with improved functional and neurological recovery. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  7. In-port derivatization coupled to different extraction techniques for the determination of alkylphenols in environmental water samples.

    PubMed

    Cavalheiro, J; Monperrus, M; Amouroux, D; Preud'Homme, H; Prieto, A; Zuloaga, O

    2014-05-02

    Large volume injection (LVI)-in port silylation coupled to gas chromatography-mass spectrometry (GC-MS) for the determination of alkylphenols (APs) in water samples applying four different extraction approaches was evaluated. Among the variables studied for in-port derivatization, vent time, cryo-focusing temperature and the ratio solvent volume/N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA) volume were optimized using an experimental design approach. Regarding the extraction techniques, different approaches previously optimized in the research group were tested. On the one hand different polymeric materials were tested: silicon rod (SR), polyethersulfone (PES) and polydimethylsiloxane (PDMS), the latter in the stir-bar sorptive extraction format (SBSE-PDMS). PES was chosen among the polymeric materials due to the higher recoveries (compared with SR) and lower price (compared to PDMS in the stir-bar sorptive extraction, SBSE-PDMS). Both MASE and PES protocols were selected at this point for further method validation and application to real samples. Finally, the developed methods were validated and applied to the determination of target analytes in various aqueous environmental matrices, including estuarine water and wastewater. Acceptable repeatability in the case of MASE (5-17%) and PES (7-21%) procedures and method detection limits (MDLs, 5-123 and 28-328 ng L(-1) for PES and MASE, respectively) were obtained for most analytes. In terms of apparent recoveries in the presence of matrix, estuarine and effluent samples showed no significant matrix effect (apparent recoveries in the 73-121% for PES and 74-128% for MASE), while a stronger matrix effect was observed for influent wastewater samples (98-132% for PES and 65-156% for MASE). Both MASE and PES extractions combined with LVI-in-port derivatization-GC-MS were applied to the determination of APs in the estuary of Bilbao (Gulf of Biscay, Spain). Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Evidence against a bacterial endotoxin masking effect in biologic drug products by limulus amebocyte lysate detection.

    PubMed

    Bolden, Jay S; Claerbout, Mark E; Miner, Matthew K; Murphy, Marie A; Smith, Kelly R; Warburton, Rob E

    2014-01-01

    The inability to detect endotoxin using compendia methods is a potential safety concern for patients due to the lack of endotoxin removal capabilities at the fill-finish stage in typical aseptic biologic drug product manufacturing. We have successfully demonstrated endotoxin challenge study recovery methodology using mammalian cell-produced biologic drug products and drug substances in citrate, histidine, phosphate, and sodium acetate buffer formulations containing polysorbate, challenged with an endotoxin analyte, for up to 6 months of storage. Successful recovery was similarly demonstrated for a preserved, peptide-containing drug product formulation. To isolate a potential masking-or low-endotoxin recovery-source, additional studies were performed to evaluate factors including product manufacturing contact surfaces, drug product matrix with and without polysorbate, individual matrix components, protein concentration, reagent suppliers, an orthogonal test method, and storage conditions. In all cases, acceptable recoveries were observed. Bacterial endotoxin is known to be chemically stable at physiological conditions. Purified endotoxin in aqueous conditions is likely to self-aggregate or bind to surfaces. Neither the nature of, nor the storage conditions of, the studied formulation matrices were shown experimentally to render the challenge endotoxin biologically inactive. The results highlight the importance of appropriate study design in assessing the recovery of endotoxins. Bacterial endotoxin is a Gram-negative bacterial cell wall component that is harmful to humans at threshold concentrations, and it is not expected to be in aseptically-produced pharmaceutical medicines. It has been suggested that endotoxin cannot be detected over time in certain biopharmaceutical drug product formulations containing citrate, phosphate, and polysorbate components via an unknown masking mechanism. We have generated and present data here that indicate that endotoxin can be recovered in a variety of matrices, and under various experimental conditions. © PDA, Inc. 2014.

  9. Electrospun polystyrene/oxidized carbon nanotubes film as both sorbent for thin film microextraction and matrix for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.

    PubMed

    He, Xiao-Mei; Zhu, Gang-Tian; Yin, Jia; Zhao, Qin; Yuan, Bi-Feng; Feng, Yu-Qi

    2014-07-18

    In the current study, polystyrene/oxidized carbon nanotubes (PS/OCNTs) film was prepared and applied as both an adsorbent of thin film microextraction (TFME) and matrix for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) for the first time. The uniform size of PS/OCNTs film with OCNTs evenly and firmly immobilized in PS was obtained by electrospinning. And a novel TFME device was developed using the prepared PS/OCNTs film to enrich benzo[a]pyrene (BaP) from water, and also BaP and 1-hydroxypyrene (1-OHP) from urine sample. Then the extracted analytes on the PS/OCNTs film were directly applied to MALDI-MS analysis with PS/OCNTs film as the MALDI matrix. Our results show that PS/OCNTs film is a good TFME adsorbent toward the analytes and an excellent matrix for the sensitive determination of BaP and 1-OHP using MALDI-TOF-MS. The employment of PS/OCNTs as the matrix for MALDI can effectively avoid the large variation of signal intensity normally resulting from heterogeneous distribution of the adsorbed analyte on matrix layer, which therefore significantly improve spot-to-spot reproducibility. The introduction of PS in the film can prevent OCNTs from flying out of MALDI plate to damage the equipment. In addition, PS/OCNTs film also largely extended the duration of ion signal of target analyte compared to OCNTs matrix. The developed method was further successfully used to quantitatively determine BaP in environmental water and 1-OHP in urine samples. The results show that BaP and 1-OHP could be easily detected at concentrations of 50pgmL(-1) and 500pgmL(-1), respectively, indicating the high detection sensitivity of this method. For BaP analysis, the linear range was 0.1-20ngmL(-1) with a correlation coefficient of 0.9970 and the recoveries were in the range of 81.3 to 123.4% with the RSD≤8.5% (n=3); for urinary 1-OHP analysis, the linear range was 0.5-20ngmL(-1) with a correlation coefficient of 0.9937 and the recoveries were in the range of 79.2 to 103.4% with the RSD≤7.6% (n=3). Taken together, the developed method provides a simple, rapid, cost-effective and high-throughput approach for the analysis of BaP in environmental water and endogenous 1-OHP in urine samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Sacrificial adsorbate for surfactants utilized in chemical floods of enhanced oil recovery operations

    DOEpatents

    Johnson, Jr., James S.; Westmoreland, Clyde G.

    1982-01-01

    The present invention is directed to a sacrificial or competitive adsorbate for surfactants contained in chemical flooding emulsions for enhanced oil recovery operations. The adsorbate to be utilized in the method of the present invention is a caustic effluent from the bleach stage or the weak black liquor from the digesters and pulp washers of the kraft pulping process. This effluent or weak black liquor is injected into an oil-bearing subterranean earth formation prior to or concurrent with the chemical flood emulsion and is adsorbed on the active mineral surfaces of the formation matrix so as to effectively reduce adsorption of surfactant in the chemical flood. Alternatively, the effluent or liquor can be injected into the subterranean earth formation subsequent to a chemical flood to displace the surfactant from the mineral surfaces for the recovery thereof.

  11. Sacrificial adsorbate for surfactants utilized in chemical floods of enhanced oil recovery operations

    DOEpatents

    Johnson, J.S. Jr.; Westmoreland, C.G.

    1980-08-20

    The present invention is directed to a sacrificial or competitive adsorbate for surfactants contained in chemical flooding emulsions for enhanced oil recovery operations. The adsorbate to be utilized in the method of the present invention is a caustic effluent from the bleach stage or the weak black liquor from the digesters and pulp washers of the kraft pulping process. This effluent or weak black liquor is injected into an oil-bearing subterranean earth formation prior to or concurrent with the chemical flood emulsion and is adsorbed on the active mineral surfaces of the formation matrix so as to effectively reduce adsorption of surfactant in the chemical flood. Alternatively, the effluent or liquor can be injected into the subterranean earth formation subsequent to a chemical flood to displace the surfactant from the mineral surfaces for the recovery thereof.

  12. Multi-residue determination of pesticides in tropical fruits using liquid chromatography/tandem mass spectrometry.

    PubMed

    Botero-Coy, A M; Marín, J M; Ibáñez, M; Sancho, J V; Hernández, F

    2012-03-01

    Monitoring pesticide residues in tropical fruits is of great interest for many countries, e.g., from South America, that base an important part of their economy on the exportation of these products. In this work, a LC-MS/MS multi-residue method using a triple quadrupole analyzer has been developed for around 30 pesticides in seven Colombian tropical fruits of high commercial value for domestic and international markets (uchuva, tamarillo, granadilla, gulupa, maracuya, papaya, and pithaya). After sample extraction with acetonitrile, an aliquot of the extract was diluted with water and directly injected into the HPLC-MS/MS system (electrospray interface) without any cleanup step. The formation of sodium adducts-of poor fragmentation-was minimized using 0.1% formic acid in the mobile phase, which favored the formation of the protonated molecule. However, the addition of ammonium acetate made the formation of the ammonium adducts in some particular cases possible, avoiding the presence of the sodium adducts. The highest sensitivity was observed in positive electrospray ionization for the wide majority of pesticides, with a few exceptions for acidic compounds that gave better response in the negative mode (e.g., 2,4-D, fluazinan). Thus, simultaneous acquisition on the positive/negative mode was applied. Two MS/MS transitions were acquired for each compound to ensure a reliable quantification and identification of the compounds detected in samples, although for malathion a third transition was acquired due to the presence of interfering isobaric compounds in the sample extracts. A detailed study of matrix effects was made by a comparison of standards in solvent and in matrix. Both ionization suppression and ionization enhancement were observed depending on the analyte/matrix combination tested. Correction of matrix effects was made by the application of calibration in matrix. Three matrices were selected (uchuva, maracuya, gulupa) to perform matrix calibration in the analysis of all seven fruit varieties studied. The method was validated by recovery experiments in samples spiked at two levels (0.05 and 0.5 mg/kg). The data were satisfactory for the wide majority of analyte/matrix combinations, with most recoveries between 70% and 110% and the RSD below 15%. Several samples collected from the market were finally analyzed. Positive findings were confirmed by evaluating the experimental Q/q ratios and retention times, and comparing them with those of reference standards.

  13. [Rapid determination of 40 pesticide residues in fruits using gas chromatography-mass spectrometry coupled with analyte protectants to compensate for matrix effects].

    PubMed

    Xu, Xiuli; Zhao, Haixiang; Li, Li; Liu, Hanxia; Ren, Heling; Zhong, Weike

    2012-03-01

    A gas chromatography-mass spectrometry (GC-MS) method was developed for the determination of 40 pesticides in fruits. The effects of adding analyte protectants were evaluated for compensating matrix effects and the impacts on the quantitative results. A new combination of analyte protectants - Polyethylene Glycol 400 (PEG 400) and olive oil combination, which can be dissolved in acetone, was used for the quantitative analysis. The pesticides were extracted from fruit samples with acetonitrile and the extracts were cleaned up using micro-solid phase extraction. A GC-MS method in selective ion monitoring (SIM) mode coupled with large volume injection was finally developed. Using the newly developed analyte protectant combination of PEG 400 and olive oil, a good linearity was obtained in the range of 1 - 200 microg/L with coefficients better than 0.99, and the detection limits were between 0.1 - 3.0 microg/L. The mean recoveries of the pesticides were 75% - 119% with the relative standard deviation values less than 16.6% except for dimethoate. The performance of the analyte protectants was compared with matrix-matched standards calibration curves in terms of quantitative accuracy. The results showed that the method of adding analyte protectants can replace the matrix-matched standard calibration, and can also reduce the sample pretreatment. When the devel- oped method was used for the analysis of apple, peache, orange, banana, grape and other fruit samples, a good matrix compensation effect was achieved, and thus effectively reduced the bad effects of the water-soluble agents to the gas chromatographic column.

  14. Assessment of Recovery of Milk Protein Allergens from Processed Food for Mass Spectrometry Quantification.

    PubMed

    Groves, Kate; Cryar, Adam; Walker, Michael; Quaglia, Milena

    2018-01-01

    Assessing the recovery of food allergens from solid processed matrixes is one of the most difficult steps that needs to be overcome to enable the accurate quantification of protein allergens by immunoassay and MS. A feasibility study is described herein applying International System of Units (SI)-traceably quantified milk protein solutions to assess recovery by an improved extraction method. Untargeted MS analysis suggests that this novel extraction method can be further developed to provide high recoveries for a broad range of food allergens. A solution of α-casein was traceably quantified to the SI for the content of α-S1 casein. Cookie dough was prepared by spiking a known amount of the SI-traceable quantified solution into a mixture of flour, sugar, and soya spread, followed by baking. A novel method for the extraction of protein food allergens from solid matrixes based on proteolytic digestion was developed, and its performance was compared with the performance of methods reported in the literature.

  15. Evaluation of matrix effect on the determination of rare earth elements and As, Bi, Cd, Pb, Se and In in honey and pollen of native Brazilian bees (Tetragonisca angustula - Jataí) by Q-ICP-MS.

    PubMed

    de Oliveira, Fernanda Ataide; de Abreu, Adriana Trópia; de Oliveira Nascimento, Nathália; Froes-Silva, Roberta Eliane Santos; Antonini, Yasmine; Nalini, Hermínio Arias; de Lena, Jorge Carvalho

    2017-01-01

    Bees are considered the main pollinators in natural and agricultural environments. Chemical elements from honey and pollen have been used for monitoring the environment, the health of bees and the quality of their products. Nevertheless, there are not many studies on honey and pollen of native Brazilian bees. The goal of this work was to determine important chemical elements (Sc, Y, La, Ce, Pr, Nd, Sm, Eu, Gd, Dy, Ho, Er, Tm, Lu and Yb) along with As, Bi, Cd, Pb, Se and In, in honey and pollen of native Brazilian bees, assessing analytical interferences from the matrix. A proposed analytical method was developed for these elements by quadrupole ICP-MS. Matrix effect was verified in honey matrix in the quantification of As, Bi and Dy; and in pollen matrix for Bi, Cd, Ce, Gd, La, Pb and Sc. The quality of the method was considered satisfactory taking into consideration the recovery rate of each element in the spiked solutions: honey matrix (91.6-103.9%) and pollen matrix (94.1-115.6%). The quantification limits of the method ranged between 0.00041 and 10.3μgL -1 for honey and 0.00041-0.095μgL -1 for pollen. The results demonstrate that the method is accurate, precise and suitable. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Food Matrix Effects of Polyphenol Bioaccessibility from Almond Skin during Simulated Human Digestion

    PubMed Central

    Mandalari, Giuseppina; Vardakou, Maria; Faulks, Richard; Bisignano, Carlo; Martorana, Maria; Smeriglio, Antonella; Trombetta, Domenico

    2016-01-01

    The goal of the present study was to quantify the rate and extent of polyphenols released in the gastrointestinal tract (GIT) from natural (NS) and blanched (BS) almond skins. A dynamic gastric model of digestion which provides a realistic simulation of the human stomach was used. In order to establish the effect of a food matrix on polyphenols bioaccessibility, NS and BS were either digested in water (WT) or incorporated into home-made biscuits (HB), crisp-bread (CB) and full-fat milk (FM). Phenolic acids were the most bioaccessible class (68.5% release from NS and 64.7% from BS). WT increased the release of flavan-3-ols (p < 0.05) and flavonols (p < 0.05) from NS after gastric plus duodenal digestion, whereas CB and HB were better vehicles for BS. FM lowered the % recovery of polyphenols, the free total phenols and the antioxidant status in the digestion medium, indicating that phenolic compounds could bind protein present in the food matrix. The release of bioactives from almond skins could explain the beneficial effects associated with almond consumption. PMID:27649239

  17. Matrix Effect Evaluation and Method Validation of Azoxystrobin and Difenoconazole Residues in Red Flesh Dragon Fruit (Hylocereus polyrhizus) Matrices Using QuEChERS Sample Preparation Methods Followed by LC-MS/MS Determination.

    PubMed

    Noegrohati, Sri; Hernadi, Elan; Asviastuti, Syanti

    2018-06-01

    Production of red flesh dragon fruit (Hylocereus polyrhizus) was hampered by Colletotrichum sp. Pre-harvest application of azoxystrobin and difenoconazole mixture is recommended, therefore, a selective and sensitive multi residues analytical method is required in monitoring and evaluating the commodity's safety. LC-MS/MS is a well-established analytical technique for qualitative and quantitative determination in complex matrices. However, this method is hurdled by co-eluted coextractives interferences. This work evaluated the pH effect of acetate buffered and citrate buffered QuEChERS sample preparation in their effectiveness of matrix effect reduction. Citrate buffered QuEChERS proved to produce clean final extract with relative matrix effect 0.4%-0.7%. Method validation of the selected sample preparation followed by LC-MS/MS for whole dragon fruit, flesh and peel matrices fortified at 0.005, 0.01, 0.1 and 1 g/g showed recoveries 75%-119%, intermediate repeatability 2%-14%. The expanded uncertainties were 7%-48%. Based on the international acceptance criteria, this method is valid.

  18. A Novel Riemannian Metric Based on Riemannian Structure and Scaling Information for Fixed Low-Rank Matrix Completion.

    PubMed

    Mao, Shasha; Xiong, Lin; Jiao, Licheng; Feng, Tian; Yeung, Sai-Kit

    2017-05-01

    Riemannian optimization has been widely used to deal with the fixed low-rank matrix completion problem, and Riemannian metric is a crucial factor of obtaining the search direction in Riemannian optimization. This paper proposes a new Riemannian metric via simultaneously considering the Riemannian geometry structure and the scaling information, which is smoothly varying and invariant along the equivalence class. The proposed metric can make a tradeoff between the Riemannian geometry structure and the scaling information effectively. Essentially, it can be viewed as a generalization of some existing metrics. Based on the proposed Riemanian metric, we also design a Riemannian nonlinear conjugate gradient algorithm, which can efficiently solve the fixed low-rank matrix completion problem. By experimenting on the fixed low-rank matrix completion, collaborative filtering, and image and video recovery, it illustrates that the proposed method is superior to the state-of-the-art methods on the convergence efficiency and the numerical performance.

  19. Experimental investigations of argon spark gap recovery times by developing a high voltage double pulse generator.

    PubMed

    Reddy, C S; Patel, A S; Naresh, P; Sharma, Archana; Mittal, K C

    2014-06-01

    The voltage recovery in a spark gap for repetitive switching has been a long research interest. A two-pulse technique is used to determine the voltage recovery times of gas spark gap switch with argon gas. First pulse is applied to the spark gap to over-volt the gap and initiate the breakdown and second pulse is used to determine the recovery voltage of the gap. A pulse transformer based double pulse generator capable of generating 40 kV peak pulses with rise time of 300 ns and 1.5 μs FWHM and with a delay of 10 μs-1 s was developed. A matrix transformer topology is used to get fast rise times by reducing L(l)C(d) product in the circuit. Recovery Experiments have been conducted for 2 mm, 3 mm, and 4 mm gap length with 0-2 bars pressure for argon gas. Electrodes of a sparkgap chamber are of rogowsky profile type, made up of stainless steel material, and thickness of 15 mm are used in the recovery study. The variation in the distance and pressure effects the recovery rate of the spark gap. An intermediate plateu is observed in the spark gap recovery curves. Recovery time decreases with increase in pressure and shorter gaps in length are recovering faster than longer gaps.

  20. High Precision Low-blank Lithium Isotope Ratios in Forams.

    NASA Astrophysics Data System (ADS)

    Misra, S.; Froelich, P. N.

    2007-12-01

    We present a high precision (±1‰, 2σ) low blank (<500 fg/ml) method for Li isotope measurements of forams using <2 ng of Li by single collector Quad ICP-MS (Agilent 7500cs). The Li isotope ratio of seawater (δ7Li) recorded in planktonic forams has the potential to constrain the evolution of seawater chemistry and elucidate the factors driving variations of oceanic mass balances linked to the continental and sea floor/hydrothermal silica cycles. In addition a δ7Li record of seawater will complement other long-term recorders of seawater chemistry such as Sr, Os and S isotopes. Li isotope measurements of forams are limited by several factors: low Li concentrations in forams (1-2 ppm), instrument-induced fractionation and mass bias effects, matrix effects, high Li blanks and incomplete recovery of Li during column separation. Modest concentrations of alkali and alkaline earth elements in the matrix result in variable mass bias in measured Li isotope ratios. Even worse, Li strongly fractionates during chromatographic clean-up to remove Na+, Ca2+ and Mg2+, from +100‰ in the leading edge to - 100‰ in the trailing edge of elution peaks (Urey 1938). Consequently, miniscule incomplete recoveries of Li during chromatographic separations can result in large unrecognized isotope fractionation of eluents. Large mass-dependent fractionation caused by a difference of 17% in mass between 6Li and 7Li, makes Li a powerful tracer of geochemical processes, but also promotes large and difficult-to-fix isotope fractionations during laboratory chemical processing. Matrix effects of Na & Ca and of column chromatography on Li isotope ratios were investigated using artificial Li solutions representative of foram compositions (matrix matching). Li/Ca and Li/Na ratios in cleaned forams are 10 μmol/mol and 3 mmol/mol respectively. An ICP-MS tolerance limit of 20 ppb for Na and 20 μM for Ca was established, much higher tolerances than by TIMS. A single step chromatographic method to quantitatively separate Li from matrix elements using both small volume resin (3.4 meq/2ml AG50W-X8) and acid (6 ml of 0.5N HCl) was developed. Our low blank (<0.5 pg/ml) and high yield (>99.99%) column method minimizes errors in measured Li isotope ratios associated with incomplete column recovery and presence of matrix elements. High sensitivity and precision achieved with a 7500cs using cold plasma (600W), soft extraction and peak jumping coupled with very low sample to blank ratios enables high precision (±1‰, 2σ) statistically significant Li isotope measurements using very small mass of Li (0.8 ng). The development of this technique makes possible good quality Li isotope measurements from samples that are mass limited for Li, i.e., reasonable number of picked forams. This will enable us to test interferences regarding chemical cleaning and species effects in planktonic forams along the road toward creating a δ7Li record of seawater for the Cenozoic.

  1. Determination of Flavonol Aglycones in Ginkgo biloba Dietary Supplement Crude Materials and Finished Products by High-Performance Liquid Chromatography: Single Laboratory Validation

    PubMed Central

    Gray, Dean; LeVanseler, Kerri; Pan, Meide

    2008-01-01

    A single laboratory validation (SLV) was completed for a method to determine the flavonol aglycones quercetin, kaempferol, and isorhamnetin in Ginkgo biloba products. The method calculates total glycosides based on these aglycones formed following acid hydrolysis. Nine matrixes were chosen for the study, including crude leaf material, standardized dry powder extract, single and multiple entity finished products, and ethanol and glycerol tinctures. For the 9 matrixes evaluated as part of this SLV, the method appeared to be selective and specific, with no observed interferences. The simplified 60 min oven heating hydrolysis procedure was effective for each of the matrixes studied, with no apparent or consistent differences between 60, 75, and 90 min at 90°C. A Youden ruggedness trial testing 7 factors with the potential to affect quantitative results showed that 2 factors (volume hydrolyzed and test sample extraction/hydrolysis weight) were the most important parameters for control during sample preparation. The method performed well in terms of precision, with 4 matrixes tested in triplicate over a 3-day period showing an overall repeatability (relative standard deviation, RSD) of 2.3%. Analysis of variance testing at α = 0.05 showed no significant differences among the within- or between-group sources of variation, although comparisons of within-day (Sw), between-day (Sb), and total (St) precision showed that a majority of the standard deviation came from within-day determinations for all matrixes. Accuracy testing at 2 levels (approximately 30 and 90% of the determined concentrations in standardized dry powder extract) from 2 complex negative control matrixes showed an overall 96% recovery and RSD of 1.0% for the high spike, and 94% recovery and RSD of 2.5% for the low spike. HorRat scores were within the limits for performance acceptability, ranging from 0.4 to 1.3. Based on the performance results presented herein, it is recommended that this method progress to the collaborative laboratory trial. PMID:16001841

  2. Wound healing effects of collagen-laminin dermal matrix impregnated with resveratrol loaded hyaluronic acid-DPPC microparticles in diabetic rats.

    PubMed

    Gokce, Evren H; Tuncay Tanrıverdi, Sakine; Eroglu, Ipek; Tsapis, Nicolas; Gokce, Goksel; Tekmen, Isıl; Fattal, Elias; Ozer, Ozgen

    2017-10-01

    An alternative formulation for the treatment of diabetic foot wounds that heal slowly is a requirement in pharmaceutical field. The aim of this study was to develop a dermal matrix consisting of skin proteins and lipids with an antioxidant that will enhance healing and balance the oxidative stress in the diabetic wound area due to the high levels of glucose. Thus a novel three dimensional collagen-laminin porous dermal matrix was developed by lyophilization. Resveratrol-loaded hyaluronic acid and dipalmitoylphosphatidylcholine microparticles were combined with this dermal matrix. Characterization, in vitro release, microbiological and in vivo studies were performed. Spherical microparticles were obtained with a high RSV encapsulation efficacy. The microparticles were well dispersed in the dermal matrix from the surface to deeper layers. Collagenase degraded dermal matrix, however the addition of RSV loaded microparticles delayed the degradation time. The release of RSV was sustained and reached 70% after 6h. Histological changes and antioxidant parameters in different treatment groups were investigated in full-thickness excision diabetic rat model. Collagen fibers were intense and improved by the presence of formulation without any signs of inflammation. The highest healing score was obtained with the dermal matrix impregnated with RSV-microparticles with an increased antioxidant activity. Collagen-laminin dermal matrix with RSV microparticles was synergistically effective due to presence of skin components in the formulation and controlled release achieved. This combination is a safe and promising option for the treatment of diabetic wounds requiring long recovery. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. GPU-accelerated algorithms for compressed signals recovery with application to astronomical imagery deblurring

    NASA Astrophysics Data System (ADS)

    Fiandrotti, Attilio; Fosson, Sophie M.; Ravazzi, Chiara; Magli, Enrico

    2018-04-01

    Compressive sensing promises to enable bandwidth-efficient on-board compression of astronomical data by lifting the encoding complexity from the source to the receiver. The signal is recovered off-line, exploiting GPUs parallel computation capabilities to speedup the reconstruction process. However, inherent GPU hardware constraints limit the size of the recoverable signal and the speedup practically achievable. In this work, we design parallel algorithms that exploit the properties of circulant matrices for efficient GPU-accelerated sparse signals recovery. Our approach reduces the memory requirements, allowing us to recover very large signals with limited memory. In addition, it achieves a tenfold signal recovery speedup thanks to ad-hoc parallelization of matrix-vector multiplications and matrix inversions. Finally, we practically demonstrate our algorithms in a typical application of circulant matrices: deblurring a sparse astronomical image in the compressed domain.

  4. A multi-directional tracer test in the fractured Chalk aquifer of E. Yorkshire, UK.

    PubMed

    Hartmann, S; Odling, N E; West, L J

    2007-12-07

    A multi-borehole radial tracer test has been conducted in the confined Chalk aquifer of E. Yorkshire, UK. Three different tracer dyes were injected into three injection boreholes and a central borehole, 25 m from the injection boreholes, was pumped at 330 m(3)/d for 8 days. The breakthrough curves show that initial breakthrough and peak times were fairly similar for all dyes but that recoveries varied markedly from 9 to 57%. The breakthrough curves show a steep rise to a peak and long tail, typical of dual porosity aquifers. The breakthrough curves were simulated using a 1D dual porosity model. Model input parameters were constrained to acceptable ranges determined from estimations of matrix porosity and diffusion coefficient, fracture spacing, initial breakthrough times and bulk transmissivity of the aquifer. The model gave equivalent hydraulic apertures for fractures in the range 363-384 microm, dispersivities of 1 to 5 m and matrix block sizes of 6 to 9 cm. Modelling suggests that matrix block size is the primary controlling parameter for solute transport in the aquifer, particularly for recovery. The observed breakthrough curves suggest results from single injection-borehole tracer tests in the Chalk may give initial breakthrough and peak times reasonably representative of the aquifer but that recovery is highly variable and sensitive to injection and abstraction borehole location. Consideration of aquifer heterogeneity suggests that high recoveries may be indicative of a high flow pathway adjacent, but not necessarily connected, to the injection and abstraction boreholes whereas low recoveries may indicate more distributed flow through many fractures of similar aperture.

  5. Effect of matrix composition and process conditions on casein-gelatin beads floating properties.

    PubMed

    Bulgarelli, E; Forni, F; Bernabei, M T

    2000-04-05

    Casein-gelatin beads have been prepared by emulsification extraction method and cross-linked with D,L-glyceraldehyde in an acetone-water mixture 3:1 (v/v). Casein emulsifying properties cause air bubble incorporation and the formation of large holes in the beads. The high porosity of the matrix influences the bead properties such as drug loading, drug release and floatation. These effects have been stressed by comparison with low porous beads, artificially prepared without cavities. The percentage of casein in the matrix increases the drug loading of both low and high porous matrices, although the loading of high porous matrices is lower than that of low porous matrices. As a matter of fact, the drug should be more easily removed during washing and recovery because of the higher superficial pore area of the beads. This can explain the drug release rate increase, observed in high porous matrix, in comparison with beads without cavities. This is due to the rapid diffusion of the drug through water filled pores. The study shows that cavities act as an air reservoir and enable beads to float. Therefore, casein seems to be a material suitable to the inexpensive formation of an air reservoir for floating systems.

  6. Bromination of aromatic compounds by residual bromide in sodium chloride matrix modifier salt during heated headspace GC/MS analysis.

    PubMed

    Fine, Dennis D; Ko, Saebom; Huling, Scott

    2013-12-15

    Analytical artifacts attributed to the bromination of toluene, xylenes, and trimethylbenzenes were found during the heated headspace gas chromatography/mass spectrometry (GC/MS) analysis of aqueous samples. The aqueous samples were produced from Fenton-like chemical oxidation reactions and contained aromatic compounds, hydrogen peroxide (H2O2), and ferric sulfate. Prior to GC/MS headspace analysis, the samples were acidified (pH<2), and sodium chloride was amended to the headspace vial as a matrix modifier. The brominated artifacts were generated during heated headspace analysis. Further, when samples were spiked with a mixture of volatile chlorinated and aromatic compounds (50 µg/L), poor spike recoveries of toluene and xylenes occurred, and in some cases complete loss of trimethylbenzenes and naphthalene resulted. Where poor recovery of aromatic spike compounds occurred, brominated aromatic compounds were found. The only significant source of bromine in the reaction scheme is the bromide typically present (<0.01% w/w) in the sodium chloride amended to the samples. Conversely, brominated artifacts were absent when a buffered salt mixture composed of sodium chloride and potassium phosphate dibasic/monobasic was used as a matrix modifier and raised the sample pH (pH~6). This indicated that the brominated artifacts resulted from the reaction of the aromatic compounds with BrCl, which was formed by the reaction of H2O2, chloride, and bromide under acidic conditions. An alternative matrix modifier salt is recommended that prevents the bromination reaction and avoids these deleterious effects on sample integrity during headspace analysis. Published by Elsevier B.V.

  7. Development and Validation of a Novel LC-MS/MS Opioid Confirmation Assay: Evaluation of β-glucuronidase Enzymes and Sample Cleanup Methods.

    PubMed

    Yang, He S; Wu, Alan H B; Lynch, Kara L

    2016-06-01

    With the rise in the use and misuse of prescription opioids, there is an increasing need for the confirmed identification of opioid analgesics in toxicology laboratories. The goals of this study were to (i) systematically evaluate the hydrolysis efficiency of four β-glucuronidase enzymes under optimized condition; (ii) evaluate compound recovery, matrix effects and precision of three protein precipitation plates and (iii) develop and validate a qualitative liquid-chromatography mass spectrometry (LC-MS/MS) assay to identify 13 opioids in urine. A recombinant β-glucuronidase exhibited the best overall hydrolysis efficiency for seven opioid glucuronide conjugates compared with β-glucuronidase from red abalone, Escherichia coli and Patella vulgata One of the protein precipitation plates tested exhibited overall better recovery of the opioids and lower ion suppression compared with the other two plates. An ESI positive mode LC-MS/MS assay for qualitative opioid analysis was developed and validated. Linearity, LOD, precision, matrix effect, recovery, carryover and interference of the method were evaluated. Sixty-two patient samples were analyzed by both a legacy GC-MS opioid method and the LC-MS/MS method, and 22 samples were analyzed by the LC-MS/MS and an LC-MS/MS reference method. The results of the comparisons showed good concordance. Overall, we described an efficient sample preparation procedure for a sensitive qualitative opioid confirmation assay in urine. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Highly enhanced ultraviolet photosensitivity and recovery speed in electrospun Ni-doped SnO2 nanobelts

    NASA Astrophysics Data System (ADS)

    Huang, Siya; Matsubara, Kohei; Cheng, Jing; Li, Heping; Pan, Wei

    2013-09-01

    Precisely controlled Ni-doped SnO2 (NSO) nanobelt arrays are synthesized and assembled via electrospinning. In comparison to pristine SnO2 nanobelts, enhanced photosensitivity (˜103) as well as recovery speed (˜1 s) is obtained in NSO nanobelts. The mechanism is clarified by the compensation effect of acceptor impurity Ni, which not only promotes the oxygen-surface interaction but also introduces trapping centers in SnO2 matrix. The reduced grain size (˜4 nm) along with increased depletion layer thickness also benefits the photosensitivity of NSO nanobelts. These improved photoresponse properties make the NSO nanobelt a promising candidate for high-performance ultraviolet detectors.

  9. High-Temperature Inorganic Self-Healing Inorganic Cement Composites

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pyatina, Tatiana; Sugama, Toshifumi

    The data files below summarize the results from various experiments testing properties of high-temperature self-healing inorganic cement composites. These properties include cement-carbon steel bond strength, Young's modulus recovery, matrix recovery strength, and compressive strength and Yonug's modulus for cement composites modified with Pozzolanic Clay additives.

  10. Quality-control results for ground-water and surface-water data, Sacramento River Basin, California, National Water-Quality Assessment, 1996-1998

    USGS Publications Warehouse

    Munday, Cathy; Domagalski, Joseph L.

    2003-01-01

    Evaluating the extent that bias and variability affect the interpretation of ground- and surface-water data is necessary to meet the objectives of the National Water-Quality Assessment (NAWQA) Program. Quality-control samples used to evaluate the bias and variability include annual equipment blanks, field blanks, field matrix spikes, surrogates, and replicates. This report contains quality-control results for the constituents critical to the ground- and surface-water components of the Sacramento River Basin study unit of the NAWQA Program. A critical constituent is one that was detected frequently (more than 50 percent of the time in blank samples), was detected at amounts exceeding water-quality standards or goals, or was important for the interpretation of water-quality data. Quality-control samples were collected along with ground- and surface-water samples during the high intensity phase (cycle 1) of the Sacramento River Basin NAWQA beginning early in 1996 and ending in 1998. Ground-water field blanks indicated contamination of varying levels of significance when compared with concentrations detected in environmental ground-water samples for ammonia, dissolved organic carbon, aluminum, and copper. Concentrations of aluminum in surface-water field blanks were significant when compared with environmental samples. Field blank samples collected for pesticide and volatile organic compound analyses revealed no contamination in either ground- or surface-water samples that would effect the interpretation of environmental data, with the possible exception of the volatile organic compound trichloromethane (chloroform) in ground water. Replicate samples for ground water and surface water indicate that variability resulting from sample collection, processing, and analysis was generally low. Some of the larger maximum relative percentage differences calculated for replicate samples occurred between samples having lowest absolute concentration differences and(or) values near the reporting limit. Surrogate recoveries for pesticides analyzed by gas chromatography/mass spectrometry (GC/MS), pesticides analyzed by high performance liquid chromatography (HPLC), and volatile organic compounds in ground- and surface-water samples were within the acceptable limits of 70 to 130 percent and median recovery values between 82 and 113 percent. The recovery percentages for surrogate compounds analyzed by HPLC had the highest standard deviation, 20 percent for ground-water samples and 16 percent for surface-water samples, and the lowest median values, 82 percent for ground-water samples and 91 percent for surface-water samples. Results were consistent with the recovery results described for the analytical methods. Field matrix spike recoveries for pesticide compounds analyzed using GC/MS in ground- and surface-water samples were comparable with published recovery data. Recoveries of carbofuran, a critical constituent in ground- and surface-water studies, and desethyl atrazine, a critical constituent in the ground-water study, could not be calculated because of problems with the analytical method. Recoveries of pesticides analyzed using HPLC in ground- and surface-water samples were generally low and comparable with published recovery data. Other methodological problems for HPLC analytes included nondetection of the spike compounds and estimated values of spike concentrations. Recovery of field matrix spikes for volatile organic compounds generally were within the acceptable range, 70 and 130 percent for both ground- and surface-water samples, and median recoveries from 62 to 127 percent. High or low recoveries could be related to errors in the field, such as double spiking or using spike solution past its expiration date, rather than problems during analysis. The methodological changes in the field spike protocol during the course of the Sacramento River Basin study, which included decreasing the amount of spike solu

  11. Simultaneous determination of trace migration of phthalate esters in honey and royal jelly by GC-MS.

    PubMed

    Zhou, Jinhui; Qi, Yitao; Wu, Hongmei; Diao, Qingyun; Tian, Feifei; Li, Yi

    2014-03-01

    A simple, rapid, and reliable liquid-liquid extraction coupled to GC-MS method was developed and validated for the quantification of 22 phthalate esters (PAEs) in honey and royal jelly. Instrument parameters for GC-MS were tested to obtain the satisfactory separation between 22 PAEs with high sensitivity. The extraction procedure was optimized in order to achieve the best recovery. The following criteria were used to validate the developed method: linearity, LOD, lower LOQ, precision, accuracy, matrix effect and carry-over. Correlation coefficients were >0.999 by applying the linear regression model based on the least-squares method with a weighting factor (1/x). The intra- and interday precision were within 12.7% in terms of RSD, and the accuracy was within -11.8% in terms of relative error. The mean extraction recoveries ranged between 80.1 and 110.9% for honey and royal jelly. No significant matrix effect and carry-over for PAEs were observed for the analysis of honey and royal jelly samples. A total of 20 real samples were analyzed for a mini-survey using the developed method. Seven PAEs in honey samples and five PAEs in royal jelly samples were found, indicating potential contamination with several PAEs. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Hydrophilic interaction liquid chromatography-solid phase extraction directly combined with protein precipitation for the determination of triptorelin in plasma.

    PubMed

    Wang, Jixia; Kong, Song; Yan, Jingyu; Jin, Gaowa; Guo, Zhimou; Shen, Aijin; Xu, Junyan; Zhang, Xiuli; Zou, Lijuan; Liang, Xinmiao

    2014-06-01

    Peptide drugs play a critical role in therapeutic treatment. However, as the complexity of plasma, determination of peptide drugs using liquid chromatography-tandem mass spectrometry (LC-MS/MS) is a daunting task. To solve this problem, hydrophilic interaction liquid chromatography-solid phase extraction (HILIC-SPE) directly combined with protein precipitation (PPT) was developed for the selective extraction of triptorelin from plasma. The extracts were analyzed by reversed-phase liquid chromatography (RPLC). Proteins, phospholipids and highly polar interferences could be removed from plasma by the efficient combination of PPT, HILIC-SPE and RPLC-MS/MS. This method was evaluated by matrix effect, recovery and process efficiency at different concentration levels (50, 500 and 5,000 ng/mL) of triptorelin. Furthermore, the performance of HILIC-SPE was compared with that of reversed-phase C18 SPE and hydrophilic lipophilic balance (Oasis HLB) SPE. Among them, HILIC-SPE provided the minimum matrix effect (ranging from 96.02% to 103.41%), the maximum recovery (ranging from 80.68% to 90.54%) and the satisfactory process efficiency (ranging from 82.83% to 92.95%). The validated method was successfully applied to determine triptorelin in rat plasma. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. LC-MS metabolic profiling of Arabidopsis thaliana plant leaves and cell cultures: optimization of pre-LC-MS procedure parameters.

    PubMed

    t'Kindt, Ruben; De Veylder, Lieven; Storme, Michael; Deforce, Dieter; Van Bocxlaer, Jan

    2008-08-01

    This study treats the optimization of methods for homogenizing Arabidopsis thaliana plant leaves as well as cell cultures, and extracting their metabolites for metabolomics analysis by conventional liquid chromatography electrospray ionization mass spectrometry (LC-ESI/MS). Absolute recovery, process efficiency and procedure repeatability have been compared between different pre-LC-MS homogenization/extraction procedures through the use of samples fortified before extraction with a range of representative metabolites. Hereby, the magnitude of the matrix effect observed in the ensuing LC-MS based metabolomics analysis was evaluated. Based on relative recovery and repeatability of key metabolites, comprehensiveness of extraction (number of m/z-retention time pairs) and clean-up potential of the approach (minimum matrix effects), the most appropriate sample pre-treatment was adopted. It combines liquid nitrogen homogenization for plant leaves with thermomixer based extraction using MeOH/H(2)O 80/20. As such, an efficient and highly reproducible LC-MS plant metabolomics set-up is achieved, as illustrated by the obtained results for both LC-MS (8.88%+/-5.16 versus 7.05%+/-4.45) and technical variability (12.53%+/-11.21 versus 9.31%+/-6.65) data in a comparative investigation of A. thaliana plant leaves and cell cultures, respectively.

  14. Development of a LC-MS method for simultaneous determination of amoxicillin and metronidazole in human serum using hydrophilic interaction chromatography (HILIC).

    PubMed

    Kathriarachchi, Udani L; Vidhate, Sagar S; Al-Tannak, Naser; Thomson, Alison H; da Silva Neto, Michael J J; Watson, David G

    2018-07-01

    A method was developed for the determination of amoxicillin and metronidazole in human serum. The procedure used was hydrophilic interaction chromatography (HILIC) followed by mass spectrometric (MS) detection. Chromatographic separation was achieved on a ZIC-HILIC column and the mobile phase consisted of a mixture of 0.1% (v/v) formic acid in water and 0.1% (v/v) formic acid in acetonitrile. The method was validated with regard to selectivity, accuracy, precision, calibration, lower limit of quantification (LOQ), extraction recovery and matrix effect. The LOQs were 0.0138 and 0.008 μg/ml for amoxicillin and metronidazole respectively, while for quantification purposes linearity was achieved in the range of 0.1 μg/ml to 6.4 μg/ml for both drugs with correlation coefficients >0.9990. The intraday precision (expressed as %RSD) and the accuracy (expressed as the % deviation from the nominal value) was <15% for both antibiotics at all QC levels. Extraction recoveries for both drugs and internal standards were >80%, while a considerable matrix effect (<60%) was observed for amoxicillin. Finally, the method was applied to the determination of amoxicillin and metronidazole concentrations in serum for 20 patients. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Chondroitinase injection improves keloid pathology by reorganizing the extracellular matrix with regenerated elastic fibers.

    PubMed

    Ishiko, Toshihiro; Naitoh, Motoko; Kubota, Hiroshi; Yamawaki, Satoko; Ikeda, Mika; Yoshikawa, Katsuhiro; Fujita, Hiroshi; Yamaguchi, Hiroaki; Kurahashi, Yasuhiro; Suzuki, Shigehiko

    2013-05-01

    Keloids are a proliferative fibrotic disease characterized by abnormal accumulation of extracellular matrix in the dermis. Keloid lesions lack skin plasticity due to deficiencies in elastic fiber formation in the extracellular matrix. The loss of elastic fiber is caused by excessive accumulation of chondroitin sulfate (CS), a sulfated glycosaminoglycan. However, there is no radical cure for keloids. Using a model system, we show herein that treatment of keloid tissues with chondroitinase ABC, an enzyme that specifically digests CS, improves clinical features of keloids. Keloid tissues obtained from patients were grafted on nude mice, and chondroitinase ABC was injected into the grafted keloid tissues. Chondroitinase ABC treatment significantly reduced the volume of keloid implants concomitant with recovery of elastic fiber formation. These results suggest that chondroitinase ABC injection is an effective therapy for keloid. © 2013 Japanese Dermatological Association.

  16. Nonconvex Nonsmooth Low Rank Minimization via Iteratively Reweighted Nuclear Norm.

    PubMed

    Lu, Canyi; Tang, Jinhui; Yan, Shuicheng; Lin, Zhouchen

    2016-02-01

    The nuclear norm is widely used as a convex surrogate of the rank function in compressive sensing for low rank matrix recovery with its applications in image recovery and signal processing. However, solving the nuclear norm-based relaxed convex problem usually leads to a suboptimal solution of the original rank minimization problem. In this paper, we propose to use a family of nonconvex surrogates of L0-norm on the singular values of a matrix to approximate the rank function. This leads to a nonconvex nonsmooth minimization problem. Then, we propose to solve the problem by an iteratively re-weighted nuclear norm (IRNN) algorithm. IRNN iteratively solves a weighted singular value thresholding problem, which has a closed form solution due to the special properties of the nonconvex surrogate functions. We also extend IRNN to solve the nonconvex problem with two or more blocks of variables. In theory, we prove that the IRNN decreases the objective function value monotonically, and any limit point is a stationary point. Extensive experiments on both synthesized data and real images demonstrate that IRNN enhances the low rank matrix recovery compared with the state-of-the-art convex algorithms.

  17. Supercritical extraction of lycopene from tomato industrial wastes with ethane.

    PubMed

    Nobre, Beatriz P; Gouveia, Luisa; Matos, Patricia G S; Cristino, Ana F; Palavra, António F; Mendes, Rui L

    2012-07-11

    Supercritical fluid extraction of all-E-lycopene from tomato industrial wastes (mixture of skins and seeds) was carried out in a semi-continuous flow apparatus using ethane as supercritical solvent. The effect of pressure, temperature, feed particle size, solvent superficial velocity and matrix initial composition was evaluated. Moreover, the yield of the extraction was compared with that obtained with other supercritical solvents (supercritical CO₂ and a near critical mixture of ethane and propane). The recovery of all-E-lycopene increased with pressure, decreased with the increase of the particle size in the initial stages of the extraction and was not practically affected by the solvent superficial velocity. The effect of the temperature was more complex. When the temperature increased from 40 to 60 °C the recovery of all-E-lycopene increased from 80 to 90%. However, for a further increase to 80 °C, the recovery remained almost the same, indicating that some E-Z isomerization could have occurred, as well as some degradation of lycopene. The recovery of all-E-lycopene was almost the same for feed samples with different all-E-lycopene content. Furthermore, when a batch with a higher all-E-lycopene content was used, supercritical ethane and a near critical mixture of ethane and propane showed to be better solvents than supercritical CO₂ leading to a faster extraction with a higher recovery of the carotenoid.

  18. Mixed Matrix PVDF Membranes With in Situ Synthesized PAMAM Dendrimer-Like Particles: A New Class of Sorbents for Cu(II) Recovery from Aqueous Solutions by Ultrafiltration.

    PubMed

    Kotte, Madhusudhana Rao; Kuvarega, Alex T; Cho, Manki; Mamba, Bhekie B; Diallo, Mamadou S

    2015-08-18

    Advances in industrial ecology, desalination, and resource recovery have established that industrial wastewater, seawater, and brines are important and largely untapped sources of critical metals and elements. A Grand Challenge in metal recovery from industrial wastewater is to design and synthesize high capacity, recyclable and robust chelating ligands with tunable metal ion selectivity that can be efficiently processed into low-energy separation materials and modules. In our efforts to develop high capacity chelating membranes for metal recovery from impaired water, we report a one-pot method for the preparation of a new family of mixed matrix polyvinylidene fluoride (PVDF) membranes with in situ synthesized poly(amidoamine) [PAMAM] particles. The key feature of our new membrane preparation method is the in situ synthesis of PAMAM dendrimer-like particles in the dope solutions prior to membrane casting using low-generation dendrimers (G0 and G1-NH2) with terminal primary amine groups as precursors and epichlorohydrin (ECH) as cross-linker. By using a combined thermally induced phase separation (TIPS) and nonsolvent induced phase separation (NIPS) casting process, we successfully prepared a new family of asymmetric PVDF ultrafiltration membranes with (i) neutral and hydrophilic surface layers of average pore diameters of 22-45 nm, (ii) high loadings (∼48 wt %) of dendrimer-like PAMAM particles with average diameters of ∼1.3-2.4 μm, and (iii) matrices with sponge-like microstructures characteristics of membranes with strong mechanical integrity. Preliminary experiments show that these new mixed matrix PVDF membranes can serve as high capacity sorbents for Cu(II) recovery from aqueous solutions by ultrafiltration.

  19. Production, recovery and purification of a recombinant β-galactosidase by expanded bed anion exchange adsorption.

    PubMed

    Boeris, Valeria; Balce, Izabella; Vennapusa, Rami Reddy; Arévalo Rodríguez, Miguel; Picó, Guillermo; Lahore, Marcelo Fernández

    2012-07-01

    β-Galactosidase is a hydrolase enzyme that catalyzes the hydrolysis of β-galactosides into monosaccharides; its major application in the food industry is to reduce the content of lactose in lactic products. The aim of this work is to recover this enzyme from a cell lysate by adsorption onto Streamline-DEAE in an expanded bed, avoiding, as much as possible, biomass deposition onto the adsorbent matrix. So as to achieve less cell debris-matrix interaction, the adsorbent surface was covered with polyvinyl pyrrolidone. The enzyme showed to bind in the same extent to naked and covered Streamline-DEAE (65 mg β-gal/g matrix) in batch mode in the absence of any biomass. The kinetics of the adsorption process was studied and no effect of the polyvinyl pyrrolidone covering was found. The optimal conditions for the recovery were achieved by using a lysate made of 40% wet weight of cells, a polyvinyl pyrrolidone-covered matrix/lysate ratio of 10% and carrying out the adsorption process in expanded bed with recirculation over 2h in 20 mM phosphate buffer pH 7.4. The fraction recovered after the elution contained 65% of the initial amount of enzyme with a 12.6-fold increased specific activity with respect to the lysate. The polyvinyl pyrrolidone content in the eluate was determined and found negligible. The remarkable point of this work is that it was possible to partially purify the enzyme using a feedstock containing an unusually high biomass concentration in the presence of polyvinyl pyrrolidone onto weak anion exchangers. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. Describing sorption of pharmaceuticals to lake and river sediments, and sewage sludge from UNESCO Biosphere Reserve Kristianstads Vattenrike by chromatographic asymmetry factors and recovery measurements.

    PubMed

    Svahn, Ola; Björklund, Erland

    2015-10-09

    Over the past 30 years a vast number of studies have demonstrated the presence of pharmaceutical residues in the environment. But still knowledge is scarce regarding the interaction of these emerging pollutants with various matrices in nature. A chromatographic system with on-line detection was developed to perform a sorption study of six selected pharmaceuticals to four natural sediments and dewatered digested sewage treatment plant sludge with differing physicochemical characteristics. Sorption effects, measured as asymmetry factors and recoveries, differed pronouncedly among the pharmaceuticals and between the matrices, which could be explained by basic physicochemical properties of the investigated compounds in relation to matrix characteristics. Protonated and deprotonated molecular properties had the greatest importance for sorbate-sorbent interactions. Atenolol, with cationic properties, showed the highest degree of sorption regardless of the matrix studied. Diclofenac and furosemide, both acids, showed the least tendency towards interactions to natural matrices. Among the neutral compounds bendroflumethiazide, carbamazepine and oxazepam, weaker forces, such as van der Waals, aromatic electron donor-acceptor interactions, and hydrogen forces, seemed more important to determine sorption differences. Results revealed that sorption of pharmaceuticals on natural sediments decreased in the order: atenolol (+)>bendroflumethiazide>oxazepam>carbamazepine>diclofenac (-)>furosemide (-). The matrix content of organic matter measured as total organic carbon (TOC) clearly dictated drug sorption. Beside from studying matrix interaction, these results and the developed technique and methodology might find use in the development of new removal processes of pharmaceuticals from wastewater based on improved knowledge concerning chemical interactions to filter materials. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Optimization of Mineral Separator for Recovery of Total Heavy Minerals of Bay of Bengal using Central Composite Design

    NASA Astrophysics Data System (ADS)

    Routray, Sunita; Swain, Ranjita; Rao, Raghupatruni Bhima

    2017-04-01

    The present study is aimed at investigating the optimization of a mineral separator for processing of beach sand minerals of Bay of Bengal along Ganjam-Rushikulya coast. The central composite design matrix and response surface methodology were applied in designing the experiments to evaluate the interactive effects of the three most important operating variables, such as feed quantity, wash water rate and Shake amplitude of the deck. The predicted values were found to be in good agreement with the experimental values (R2 = 0.97 for grade and 0.98 for recovery). To understand the impact of each variable, three dimensional (3D) plots were also developed for the estimated responses.

  2. Evaluation of USEPA method 1622 for detection of Cryptosporidium oocysts in stream waters

    USGS Publications Warehouse

    Simmons, O. D.; Sobsey, M.D.; Schaefer, F. W.; Francy, D.S.; Nally, R.A.; Heaney, C.D.

    2001-01-01

    To improve surveillance for Cryptosporidium oocysts in water, the US Environmental Protection Agency developed method 1622, which consists of filtration, concentration, immunomagnetic separation, fluorescent antibody and 4, 6-diamidino-2-phenylindole (DAPI) counter-staining, and microscopic evaluation. Two filters were compared for analysis of 11 stream water samples collected throughout the United States. Replicate 10-L stream water samples (unspiked and spiked with 100-250 oocysts) were tested to evaluate matrix effects. Oocyst recoveries from the stream water samples averaged 22% (standard deviation [SD] = ??17%) with a membrane disk and 12% (SD = ??6%) with a capsule filter. Oocyst recoveries from reagent water precision and recovery samples averaged 39% (SD = ??13%) with a membrane disk and 47% (SD = ??19%) with a capsule filter. These results demonstrate that Cryptosporidium oocysts can be recovered from stream waters using method 1622, but recoveries are lower than those from reagent-grade water. This research also evaluated concentrations of indicator bacteria in the stream water samples. Because few samples were oocyst-positive, relationships between detections of oocysts and concentrations of indicator organisms could not be determined.

  3. Matrix Completion Optimization for Localization in Wireless Sensor Networks for Intelligent IoT

    PubMed Central

    Nguyen, Thu L. N.; Shin, Yoan

    2016-01-01

    Localization in wireless sensor networks (WSNs) is one of the primary functions of the intelligent Internet of Things (IoT) that offers automatically discoverable services, while the localization accuracy is a key issue to evaluate the quality of those services. In this paper, we develop a framework to solve the Euclidean distance matrix completion problem, which is an important technical problem for distance-based localization in WSNs. The sensor network localization problem is described as a low-rank dimensional Euclidean distance completion problem with known nodes. The task is to find the sensor locations through recovery of missing entries of a squared distance matrix when the dimension of the data is small compared to the number of data points. We solve a relaxation optimization problem using a modification of Newton’s method, where the cost function depends on the squared distance matrix. The solution obtained in our scheme achieves a lower complexity and can perform better if we use it as an initial guess for an interactive local search of other higher precision localization scheme. Simulation results show the effectiveness of our approach. PMID:27213378

  4. pH-Responsive Hydrogel With an Anti-Glycation Agent for Modulating Experimental Periodontitis.

    PubMed

    Yu, Min-Chen; Chang, Chih-Yeun; Chao, Yi-Chi; Jheng, Yi-Han; Yang, Connie; Lee, Ning; Yu, Shan-Huey; Yu, Xin-Hong; Liu, Dean-Mo; Chang, Po-Chun

    2016-06-01

    Stimulus-responsive devices have emerged as a novel approach for local drug delivery. This study investigates the feasibility of a novel chitosan-based, pH-responsive hydrogel loaded with N-phenacylthiazolium bromide (PTB), which cleaves the crosslinks of advanced glycation end products on the extracellular matrix. A chitosan-based hydrogel loaded with PTB was fabricated, and the in vitro release profile was evaluated within pH 5.5 to 7.4. BALB/cJ mice and Sprague-Dawley rats were used to evaluate the effects during the induction and recovery phases of periodontitis, respectively, and animals in each phase were divided into four groups: 1) no periodontitis induction; 2) ligature-induced experimental periodontitis (group PR); 3) experimental periodontitis plus hydrogel without PTB (group PH); and 4) experimental periodontitis plus hydrogel with PTB (group PP). The therapeutic effects were evaluated by microcomputed tomographic imaging of periodontal bone level (PBL) loss and histomorphometry for inflammatory cell infiltration and collagen density. PTB was released faster at pH 5.5 to 6.5 and consistently slower at pH 7.4. In the induction phase, PBL and inflammatory cell infiltration were significantly reduced in group PP relative to group PR, and the loss of collagen matrix was significantly reduced relative to that observed in group PH. In the recovery phase, PBL and inflammatory cell infiltration were significantly reduced, and significantly greater collagen deposition was noted in group PP relative to groups PR and PH at 4 and 14 days after silk removal. Chitosan-based, pH-responsive hydrogels loaded with PTB can retard the initiation of and facilitate the recovery from experimental periodontitis.

  5. Polydopamine-coated magnetic nanoparticles for isolation and enrichment of estrogenic compounds from surface water samples followed by liquid chromatography-tandem mass spectrometry determination.

    PubMed

    Capriotti, Anna Laura; Cavaliere, Chiara; La Barbera, Giorgia; Piovesana, Susy; Samperi, Roberto; Zenezini Chiozzi, Riccardo; Laganà, Aldo

    2016-06-01

    Estrogens, phytoestrogens, and mycoestrogens may enter into the surface waters from different sources, such as effluents of municipal wastewater treatment plants, industrial plants, and animal farms and runoff from agricultural areas. In this work, a multiresidue analytical method for the determination of 17 natural estrogenic compounds, including four steroid estrogens, six mycoestrogens, and seven phytoestrogens, in river water samples has been developed. (Fe3O4)-based magnetic nanoparticles coated by polydopamine (Fe3O4@pDA) were used for dispersive solid-phase extraction, and the final extract was analyzed by ultra-high performance liquid chromatography coupled with tandem mass spectrometry. The Fe3O4 magnetic nanoparticles were prepared by a co-precipitation procedure, coated by pDA, and characterized by scanning electron microscopy, infrared spectroscopy, and elemental analysis. The sample preparation method was optimized in terms of extraction recovery, matrix effect, selectivity, trueness, precision, method limits of detection, and method limits of quantification (MLOQs). For all the 17 analytes, recoveries were >70 % and matrix effects were below 30 % when 25 mL of river water sample was treated with 90 mg of Fe3O4@pDA nanoparticles. Selectivity was tested by spiking river water samples with 50 other compounds (mycotoxins, antibacterials, conjugated hormones, UV filters, alkylphenols, etc.), and only aflatoxins and some benzophenones showed recoveries >60 %. This method proved to be simple and robust and allowed the determination of natural estrogenic compounds belonging to different classes in surface waters with MLOQs ranging between 0.003 and 0.1 μg L(-1). Graphical Abstract Determination of natural estrogenic compounds in water by magnetic solid phase extraction followed by liquid chromatography-tandem mass spectrometry analysis.

  6. Molecularly imprinted solid phase extraction for simultaneous determination of Δ9-tetrahydrocannabinol and its main metabolites by gas chromatography-mass spectrometry in urine samples.

    PubMed

    Nestić, Marina; Babić, Sandra; Pavlović, Dragana Mutavdžić; Sutlović, Davorka

    2013-09-10

    In presented paper analytical method based on solid-phase extraction using molecularly imprinted polymer and gas chromatography-mass spectrometry has been developed and validated for the confirmation of THC, THC-OH and THC-COOH in urine samples. Non-covalent molecularly imprinted polymers of THC-OH were prepared using different functional monomers (methacrylic acid, 4-vinylpyridine, and 2-hydroxyethyl methacrylate), ethylene glycol dimethacrylate as a cross-linker and 2,2'-azobis-isobutyronitrile as an initiator of radical polymerization. Analytes were extracted from urine samples using prepared polymer sorbent with highest binding selectivity and capability. Before extraction, urine samples were hydrolyzed with alkaline. Elution was performed with chloroform:ethyl acetate (60:40, v/v). Dry extracts were silylated with BSTFA+1% TMCS. Detection and quantification were performed using gas chromatography-mass spectrometry in single ion recording mode. The developed method was linear over the range from LOQ to 150 ng mL(-1) for all three analytes. For THC, THC-OH and THC-COOH LOD was 2.5, 1 and 1 ng mL(-1), and LOQ was 3, 2 and 2 ng mL(-1), respectively. The precision, accuracy, recovery and matrix effect were investigated at 5, 25 and 50 ng mL(-1). In the investigated concentration range recoveries were 71.9% for THC, 78.6% for THC-OH and 75.2% for THC-COOH. Matrix effect was not significant (<10%) for all analytes in the concentration range from 5 ng mL(-1) to 50 ng mL(-1). Extraction recovery on non-imprinted polymer was relatively high indicating high non-specific binding. Optimized and validated method was applied to 15 post-mortem urine samples. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  7. Development, validation, and application of a novel LC-MS/MS trace analysis method for the simultaneous quantification of seven iodinated X-ray contrast media and three artificial sweeteners in surface, ground, and drinking water.

    PubMed

    Ens, Waldemar; Senner, Frank; Gygax, Benjamin; Schlotterbeck, Götz

    2014-05-01

    A new method for the simultaneous determination of iodated X-ray contrast media (ICM) and artificial sweeteners (AS) by liquid chromatography-tandem mass spectrometry (LC-MS/MS) operated in positive and negative ionization switching mode was developed. The method was validated for surface, ground, and drinking water samples. In order to gain higher sensitivities, a 10-fold sample enrichment step using a Genevac EZ-2 plus centrifugal vacuum evaporator that provided excellent recoveries (90 ± 6 %) was selected for sample preparation. Limits of quantification below 10 ng/L were obtained for all compounds. Furthermore, sample preparation recoveries and matrix effects were investigated thoroughly for all matrix types. Considerable matrix effects were observed in surface water and could be compensated by the use of four stable isotope-labeled internal standards. Due to their persistence, fractions of diatrizoic acid, iopamidol, and acesulfame could pass the whole drinking water production process and were observed also in drinking water. To monitor the fate and occurrence of these compounds, the validated method was applied to samples from different stages of the drinking water production process of the Industrial Works of Basel (IWB). Diatrizoic acid was found as the most persistent compound which was eliminated by just 40 % during the whole drinking water treatment process, followed by iopamidol (80 % elimination) and acesulfame (85 % elimination). All other compounds were completely restrained and/or degraded by the soil and thus were not detected in groundwater. Additionally, a direct injection method without sample preparation achieving 3-20 ng/L limits of quantification was compared to the developed method.

  8. Arsenic Promotes NF-Kb-Mediated Fibroblast Dysfunction and Matrix Remodeling to Impair Muscle Stem Cell Function

    PubMed Central

    Zhang, Changqing; Ferrari, Ricardo; Beezhold, Kevin; Stearns-Reider, Kristen; D’Amore, Antonio; Haschak, Martin; Stolz, Donna; Robbins, Paul D.; Barchowsky, Aaron; Ambrosio, Fabrisia

    2016-01-01

    Arsenic is a global health hazard that impacts over 140 million individuals worldwide. Epidemiological studies reveal prominent muscle dysfunction and mobility declines following arsenic exposure; yet, mechanisms underlying such declines are unknown. The objective of this study was to test the novel hypothesis that arsenic drives a maladaptive fibroblast phenotype to promote pathogenic myomatrix remodeling and compromise the muscle stem (satellite) cell (MuSC) niche. Mice were exposed to environmentally relevant levels of arsenic in drinking water before receiving a local muscle injury. Arsenic-exposed muscles displayed pathogenic matrix remodeling, defective myofiber regeneration and impaired functional recovery, relative to controls. When naïve human MuSCs were seeded onto three-dimensional decellularized muscle constructs derived from arsenic-exposed muscles, cells displayed an increased fibrogenic conversion and decreased myogenicity, compared with cells seeded onto control constructs. Consistent with myomatrix alterations, fibroblasts isolated from arsenic-exposed muscle displayed sustained expression of matrix remodeling genes, the majority of which were mediated by NF-κB. Inhibition of NF-κB during arsenic exposure preserved normal myofiber structure and functional recovery after injury, suggesting that NF-κB signaling serves as an important mechanism of action for the deleterious effects of arsenic on tissue healing. Taken together, the results from this study implicate myomatrix biophysical and/or biochemical characteristics as culprits in arsenic-induced MuSC dysfunction and impaired muscle regeneration. It is anticipated that these findings may aid in the development of strategies to prevent or revert the effects of arsenic on tissue healing and, more broadly, provide insight into the influence of the native myomatrix on stem cell behavior. PMID:26537186

  9. Development and validation of a QuEChERS based liquid chromatography tandem mass spectrometry method for the determination of multiple mycotoxins in spices.

    PubMed

    Yogendrarajah, Pratheeba; Van Poucke, Christof; De Meulenaer, Bruno; De Saeger, Sarah

    2013-07-05

    A reliable and rapid method for the determination of multiple mycotoxins was developed using a QuEChERS (quick, easy, cheap, effective, rugged and safe) based extraction procedure in highly pigmented and complex spice matrices, namely red chilli (Capsicum annum ssp.), black and white pepper (Piper nigrum ssp.). High-performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS) was used for the quantification and confirmation of 17 chemically diversified mycotoxins. Different extraction procedures were studied and optimized in order to obtain better recoveries. Mycotoxins were extracted from the hydrated spices using acidified acetonitrile (1% formic acid), followed by partitioning with NaCl and anhydrous MgSO4; excluding the use of dispersive-solid phase extraction. Significant matrix effect was compensated using the matrix matched calibration curves. Electrospray ionization at positive mode was applied to simultaneously detect all the mycotoxins in a single run time of 20min. Multiple reaction monitoring mode, choosing at least two abundant fragment ions per analyte was applied. Coefficients of determination obtained were in the range of 0.9844-0.9997. Recoveries (ranging from 75% to 117%) were in accordance with the performance criteria required by the European Commission. Intra-day reproducibility ranged from 4% to 22% for most of the mycotoxins. The limit of quantification ranged from 2.3 to 146μgkg(-1). The validated method was finally applied to screen mycotoxins in ten of each spice matrix. Aflatoxins, ochratoxin, fumonisins, sterigmatocystin and citrinin were among the detected analytes. Positive findings were further confirmed using relative ion intensities. The potentiality of the method to be used for confirmatory purposes according to Commission Decision 2002/657/EC was assessed. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. On multivariate trace inequalities of Sutter, Berta, and Tomamichel

    NASA Astrophysics Data System (ADS)

    Lemm, Marius

    2018-01-01

    We consider a family of multivariate trace inequalities recently derived by Sutter, Berta, and Tomamichel. These inequalities generalize the Golden-Thompson inequality and Lieb's triple matrix inequality to an arbitrary number of matrices in a way that features complex matrix powers (i.e., certain unitaries). We show that their inequalities can be rewritten as an n-matrix generalization of Lieb's original triple matrix inequality. The complex matrix powers are replaced by resolvents and appropriate maximally entangled states. We expect that the technically advantageous properties of resolvents, in particular for perturbation theory, can be of use in applications of the n-matrix inequalities, e.g., for analyzing the performance of the rotated Petz recovery map in quantum information theory and for removing the unitaries altogether.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Secchieri, M.; Benassi, C.A.; Pastore, S.

    A method for the quail-quantitative evaluation of pentachlorophenol (PCP) in solid matrixes has been developed. The procedure is based on solid-liquid extraction of solid samples (leather or wood), followed by purification on a cyanopropyl column and determination of the preservative by second derivative UV spectroscopy considering the PCP A peak-through value (304-297 nm). The method allows rapid PCP determination in the concentration range 1-40 micrograms/mL; any matrix interference is avoided by the purification step and recoveries of the preservative were 99.12% (RSD% 0.13) for the leather matrix and 98.03 (RSD% 0.17) for the wood matrix.

  12. Depot effect of bioactive components in experimental membrane filtrations

    NASA Astrophysics Data System (ADS)

    Mitev, D.; Peshev, D.; Peev, G.; Peeva, L.

    2017-01-01

    Depot effects were found to be accompanying phenomena of membrane separation processes. Accumulation of target species in the membrane matrix during feasibility tests can hamper proper conclusions or compromise the filtration results. Therefore, we investigated the effects of delayed membrane release of chlorogenic acid and caffeine, considered as key compounds of interest in spent coffee products’ recovery treatment. Permeate fluxes and key components release were studied in course of 24 hours via nanofiltration of pure solvent, both immediately after the mock solution filtration and after idle stay. Conclusions are drawn and recommendations advised for proper analysis of experimental data on membrane screening.

  13. Determination of germanium by AAS in chloride-containing matrices.

    PubMed

    Anwari, M A; Abbasi, H U; Volkan, M; Ataman, O Y

    1996-06-01

    Interference effects of NaCl on the ET-AAS determination of Ge have been studied. The use of several matrix modifiers to alleviate this problem such as Ni and Zn perchlorates and nitrates, nitric acid, ammonium nitrate are reported. The stabilizing effect of Zn and Ni perchlorates allows the use of high pretreatment temperatures. NaCl is thus thermally volatilized from the atomizer by employing pretreatment temperatures higher than 1500 degrees C resulting in an improved sensitivity. Germanium levels in zinc plant slag samples, have been determined and compared to those obtained for the same samples spiked with NaCl with platform and wall atomization using nickel perchlorate as a matrix modifier. The results were compared with those from a hydride generation system equipped with a liquid nitrogen trap. The recoveries for germanium have been almost complete and amount to 99% for the original slag samples and 80% for 15% (w/w) NaCl containing spiked samples.

  14. Pesticide analysis in teas and chamomile by liquid chromatography and gas chromatography tandem mass spectrometry using a modified QuEChERS method: validation and pilot survey in real samples.

    PubMed

    Lozano, Ana; Rajski, Łukasz; Belmonte-Valles, Noelia; Uclés, Ana; Uclés, Samanta; Mezcua, Milagros; Fernández-Alba, Amadeo R

    2012-12-14

    This paper presents the validation of a modified QuEChERS method in four matrices - green tea, red tea, black tea and chamomile. The experiments were carried out using blank samples spiked with a solution of 86 pesticides (insecticides, fungicides and herbicides) at four levels - 10, 25, 50 and 100 μg/kg. The samples were extracted according to the citrate QuEChERS protocol; however, to reduce the amount of coextracted matrix compounds, calcium chloride was employed instead of magnesium sulphate in the clean-up step. The samples were analysed by LC-MS/MS and GC-MS/MS. Included in the scope of validation were: recovery, linearity, matrix effects, limits of detection and quantitation as well as intra-day and inter-day precision. The validated method was used in a real sample survey carried out on 75 samples purchased in ten different countries. In all matrices, recoveries of the majority of compounds were in the 70-120% range and were characterised by precision lower than 20%. In 85% of pesticide/matrix combinations the analytes can be detected quantitatively by the proposed method at the European Union Maximum Residue Level. The analysis of the real samples revealed that large number of teas and chamomiles sold in the European Union contain pesticides whose usage is not approved and also pesticides in concentrations above the EU MRLs. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. Efficient subtle motion detection from high-speed video for sound recovery and vibration analysis using singular value decomposition-based approach

    NASA Astrophysics Data System (ADS)

    Zhang, Dashan; Guo, Jie; Jin, Yi; Zhu, Chang'an

    2017-09-01

    High-speed cameras provide full field measurement of structure motions and have been applied in nondestructive testing and noncontact structure monitoring. Recently, a phase-based method has been proposed to extract sound-induced vibrations from phase variations in videos, and this method provides insights into the study of remote sound surveillance and material analysis. An efficient singular value decomposition (SVD)-based approach is introduced to detect sound-induced subtle motions from pixel intensities in silent high-speed videos. A high-speed camera is initially applied to capture a video of the vibrating objects stimulated by sound fluctuations. Then, subimages collected from a small region on the captured video are reshaped into vectors and reconstructed to form a matrix. Orthonormal image bases (OIBs) are obtained from the SVD of the matrix; available vibration signal can then be obtained by projecting subsequent subimages onto specific OIBs. A simulation test is initiated to validate the effectiveness and efficiency of the proposed method. Two experiments are conducted to demonstrate the potential applications in sound recovery and material analysis. Results show that the proposed method efficiently detects subtle motions from the video.

  16. Multichannel myopic deconvolution in underwater acoustic channels via low-rank recovery

    PubMed Central

    Tian, Ning; Byun, Sung-Hoon; Sabra, Karim; Romberg, Justin

    2017-01-01

    This paper presents a technique for solving the multichannel blind deconvolution problem. The authors observe the convolution of a single (unknown) source with K different (unknown) channel responses; from these channel outputs, the authors want to estimate both the source and the channel responses. The authors show how this classical signal processing problem can be viewed as solving a system of bilinear equations, and in turn can be recast as recovering a rank-1 matrix from a set of linear observations. Results of prior studies in the area of low-rank matrix recovery have identified effective convex relaxations for problems of this type and efficient, scalable heuristic solvers that enable these techniques to work with thousands of unknown variables. The authors show how a priori information about the channels can be used to build a linear model for the channels, which in turn makes solving these systems of equations well-posed. This study demonstrates the robustness of this methodology to measurement noises and parametrization errors of the channel impulse responses with several stylized and shallow water acoustic channel simulations. The performance of this methodology is also verified experimentally using shipping noise recorded on short bottom-mounted vertical line arrays. PMID:28599565

  17. Quantitation of fumonisin B1 and B2 in feed using FMOC pre-column derivatization with HPLC and fluorescence detection.

    PubMed

    Smith, Lori L; Francis, Kyle A; Johnson, Joseph T; Gaskill, Cynthia L

    2017-11-01

    Pre-column derivatization with 9-fluorenylmethyl chloroformate (FMOC-Cl) was determined to be effective for quantitation of fumonisins B 1 and B 2 in feed. Liquid-solid extraction, clean-up using immunoaffinity solid phase extraction chromatography, and FMOC-derivatization preceded analysis by reverse phase HPLC with fluorescence. Instrument response was unchanged in the presence of matrix, indicating no need to use matrix-matched calibrants. Furthermore, high method recoveries indicated calibrants do not need to undergo clean-up to account for analyte loss. Established method features include linear instrument response from 0.04-2.5µg/mL and stable derivatized calibrants over 7days. Fortified cornmeal method recoveries from 0.1-30.0μg/g were determined for FB 1 (75.1%-109%) and FB 2 (96.0%-115.2%). Inter-assay precision ranged from 1.0%-16.7%. Method accuracy was further confirmed using certified reference material. Inter-laboratory comparison with naturally-contaminated field corn demonstrated equivalent results with conventional derivatization. These results indicate FMOC derivatization is a suitable alternative for fumonisins B 1 and B 2 quantitation in corn-based feeds. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Development and validation of carbofuran and 3-hydroxycarbofuran analysis by high-pressure liquid chromatography with diode array detector (HPLC-DAD) for forensic Veterinary Medicine.

    PubMed

    Gonçalves, Vagner; Hazarbassanov, Nicolle Queiroz; de Siqueira, Adriana; Florio, Jorge Camilo; Ciscato, Claudia Helena Pastor; Maiorka, Paulo Cesar; Fukushima, André Rinaldi; de Souza Spinosa, Helenice

    2017-10-15

    Agricultural pesticides used with the criminal intent to intoxicate domestic and wild animals are a serious concern in Veterinary Medicine. In order to identify the pesticide carbofuran and its metabolite 3- hydroxycarbofuran in animals suspected of exogenous intoxication a high pressure liquid chromatography with diode array detector (HPLC-DAD) method was developed and validated in stomach contents, liver, vitreous humor and blood. The method was evaluated using biological samples from seven different animal species. The following parameters of analytical validation were evaluated: linearity, precision, accuracy, selectivity, recovery and matrix effect. The method was linear at the range of 6.25-100μg/mL and the correlation coefficient (r 2 ) values were >0.9811 for all matrices. The precision and accuracy of the method was determined by coefficient of variation (CV) and the relative standard deviation error (RSE), and both were less than 15%. Recovery ranged from 74.29 to 100.1% for carbofuran and from 64.72 to 100.61% for 3-hydroxycarbofuran. There were no significant interfering peaks or matrix effects. This method was suitable for detecting 25 positive cases for carbofuran amongst a total of 64 animal samples suspected of poisoning brought to the Toxicology Diagnostic Laboratory, School of Veterinary Medicine and Animal Sciences, University of Sao Paulo. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Multiclass screening method based on solvent extraction and liquid chromatography-tandem mass spectrometry for the determination of antimicrobials and mycotoxins in egg.

    PubMed

    Capriotti, Anna Laura; Cavaliere, Chiara; Piovesana, Susy; Samperi, Roberto; Laganà, Aldo

    2012-12-14

    A QuEChERS (Quick Easy Cheap Effective Rugged Safe)-like extraction method was developed for the simultaneous analysis of veterinary drugs and mycotoxins in hen eggs by liquid chromatography-tandem mass spectrometry (LC-MS/MS) with electrospray (ESI) source. Various classes of antimicrobials (tetracyclines, ionophores, coccidiostats, penicillins, cephalosporins, fluoroquinolones, sulfonamides) and mycotoxins (enniatins, beauvericin, ochratoxins, aflatoxins) were considered for the development of this method. Particular attention was devoted to extraction optimization: different solvents (acetone, acetonitrile and methanol), different pH values and different sample to extracting volume ratios were tested and evaluated in terms of recovery, relative standard deviation (RSD) and ESI signal suppression due to matrix effect. Chromatographic and mass spectrometric conditions were optimized to obtain the best instrumental performances for most of the analytes. Quantitative analysis was performed by means of matrix-matched calibration, in a range that varied depending on the analyte and its established maximum limit, when there was one. Recoveries at 100 μg kg(-1) spiking level were >62% (3

  20. Multi-modal imaging of long-term recovery post-stroke by positron emission tomography and matrix-assisted laser desorption/ionisation mass spectrometry.

    PubMed

    Henderson, Fiona; Hart, Philippa J; Pradillo, Jesus M; Kassiou, Michael; Christie, Lidan; Williams, Kaye J; Boutin, Herve; McMahon, Adam

    2018-05-15

    Stroke is a leading cause of disability worldwide. Understanding the recovery process post-stroke is essential; however, longer-term recovery studies are lacking. In vivo positron emission tomography (PET) can image biological recovery processes, but is limited by spatial resolution and its targeted nature. Untargeted mass spectrometry imaging offers high spatial resolution, providing an ideal ex vivo tool for brain recovery imaging. Magnetic resonance imaging (MRI) was used to image a rat brain 48 h after ischaemic stroke to locate the infarcted regions of the brain. PET was carried out 3 months post-stroke using the tracers [ 18 F]DPA-714 for TSPO and [ 18 F]IAM6067 for sigma-1 receptors to image neuroinflammation and neurodegeneration, respectively. The rat brain was flash-frozen immediately after PET scanning, and sectioned for matrix-assisted laser desorption/ionisation mass spectrometry (MALDI-MS) imaging. Three months post-stroke, PET imaging shows minimal detection of neurodegeneration and neuroinflammation, indicating that the brain has stabilised. However, MALDI-MS images reveal distinct differences in lipid distributions (e.g. phosphatidylcholine and sphingomyelin) between the scar and the healthy brain, suggesting that recovery processes are still in play. It is currently not known if the altered lipids in the scar will change on a longer time scale, or if they are stabilised products of the brain post-stroke. The data demonstrates the ability to combine MALD-MS with in vivo PET to image different aspects of stroke recovery. Copyright © 2018 John Wiley & Sons, Ltd.

  1. Results of quality-control sampling of water, bed sediment, and tissue in the Western Lake Michigan Drainages study unit of the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Fitzgerald, S.A.

    1997-01-01

    This report contains the quality control results of the Western Lake Michigan Drainages study unit of the National Water Quality Assessment Program. Quality control samples were collected in the same manner and contemporaneously with environmental samples during the first highintensity study phase in the unit (1992 through 1995) and amounted to approximately 15 percent of all samples collected. The accuracy and precision of hundreds of chemical analyses of surface and ground-water, bed sediment, and tissue was determined through the collection and analysis of field blanks, field replicates and splits, matrix spikes, and surrogates. Despite the several detections of analytes in the field blanks, the concentrations of most constituents in the environmental samples will likely be an order of magnitude or higher than those in the blanks. However, frequent detections, and high concentrations, of dissolved organic carbon (DOC) in several surface and ground-water blanks are probably significant with respect to commonly measured environmental concentrations, and the environmental data will have to be qualified accordingly. The precision of sampling of water on a percent basis, as determined from replicates and splits, was generally proportional to the concentration of the constituents, with constituents present in relatively high concentrations generally having less sampling variability than those with relatively low concentrations. In general, analytes with relatively high variability between replicates were present at concentrations near the reporting limit or were associated with relatively small absolute concentration differences, or both. Precision of replicates compared to that for splits in bed sediment samples was similar, thus eliminating sampling as a major source of variability in analyte concentrations. In the case the phthalates in bed sediment, contamination in either the field or laboratory could have caused the relatively large variability between replicate samples and between split samples.Variability of analyte concentrations in tissue samples was relatively low, being 29 percent or less for all constituents. Recoveries of most laboratory schedule 2001/2010 pesticide spike compounds in surfacewater samples were reasonably good. Low intrinsic method recovery resulted in relatively low recovery forp,p'-DDE, metribuzin, and propargite. In the case of propargite, decomposition with the environmental sample matrices was also indicated. Recoveries of two compounds, cyanazine and thiobencarb, might have been biased high due to interferences. The one laboratory schedule 2050/2051 field matrix pesticide spike indicated numerous operational problems with this method that biased recoveries either low or high. Recoveries of pesticides from both pesticide schedules in field spikes of ground-water samples generally were similar to those of field matrix spikes of surface- water samples. High maximum recoveries were noted for tebuthiuron, disulfoton, DCPA, and permethrin, which indicates the possible presence of interferents in the matrices for these compounds. Problems in the recoveries of pesticides on schedule 2050/2051 from ground-water samples generally were the same as those for surfacewater samples. Recoveries of VOCs in field matrix spikes were reasonable when consideration was given for the use of the micropipettor that delivered only about 80 percent on average of the nominal mass of spiked analytes. Finally, the recoveries of most surrogate compounds in surface and ground-water samples were reasonable. Problems in sample handling (for example, spillage) were likely not the cause of any of the low recoveries of spiked compounds.

  2. Mapping the spatiotemporal evolution of solute transport in articular cartilage explants reveals how cartilage recovers fluid within the contact area during sliding.

    PubMed

    Graham, Brian T; Moore, Axel C; Burris, David L; Price, Christopher

    2018-04-11

    The interstitial fluid within articular cartilage shields the matrix from mechanical stresses, reduces friction and wear, enables biochemical processes, and transports solutes into and out of the avascular extracellular matrix. The balanced competition between fluid exudation and recovery under load is thus critical to the mechanical and biological functions of the tissue. We recently discovered that sliding alone can induce rapid solute transport into buried cartilage contact areas via a phenomenon termed tribological rehydration. In this study, we use in situ confocal microscopy measurements to track the spatiotemporal propagation of a small neutral solute into the buried contact area to clarify the fluid mechanics underlying the tribological rehydration phenomenon. Sliding experiments were interrupted by periodic static loading to enable scanning of the entire contact area. Spatiotemporal patterns of solute transport combined with tribological data suggested pressure driven flow through the extracellular matrix from the contact periphery rather than into the surface via a fluid film. Interestingly, these testing interruptions also revealed dynamic, repeatable and history-independent fluid loss and recovery processes consistent with those observed in vivo. Unlike the migrating contact area, which preserves hydration by moving faster than interstitial fluid can flow, our results demonstrate that the stationary contact area can maintain and actively recover hydration through a dynamic competition between load-induced exudation and sliding-induced recovery. The results demonstrate that sliding contributes to the recovery of fluid and solutes by cartilage within the contact area while clarifying the means by which it occurs. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Body fluid matrix evaluation on a Roche cobas 8000 system.

    PubMed

    Owen, William E; Thatcher, Mindy L; Crabtree, Karolyn J; Greer, Ryan W; Strathmann, Frederick G; Straseski, Joely A; Genzen, Jonathan R

    2015-09-01

    Chemical analysis of body fluids is commonly requested by physicians. Because most commercial FDA-cleared clinical laboratory assays are not validated by diagnostic manufacturers for "non-serum" and "non-plasma" specimens, laboratories may need to complete additional validation studies to comply with regulatory requirements regarding body fluid testing. The objective of this report is to perform recovery studies to evaluate potential body fluid matrix interferences for commonly requested chemistry analytes. Using an IRB-approved protocol, previously collected clinical body fluid specimens (biliary/hepatic, cerebrospinal, dialysate, drain, pancreatic, pericardial, peritoneal, pleural, synovial, and vitreous) were de-identified and frozen (-20°C) until experiments were performed. Recovery studies (spiking with high concentration serum, control, and/or calibrator) were conducted using 10% spiking solution by volume; n=5 specimens per analyte/body fluid investigated. Specimens were tested on a Roche cobas 8000 system (c502, c702, e602, and ISE modules). In all 80 analyte/body fluid combinations investigated (including amylase, total bilirubin, urea nitrogen, carbohydrate antigen 19-9, carcinoembryonic antigen, cholesterol, chloride, creatinine, glucose, potassium, lactate dehydrogenase, lipase, rheumatoid factor, sodium, total protein, triglycerides, and uric acid), the average percent recovery was within predefined acceptable limits (less than ±10% from the calculated ideal recovery). The present study provides evidence against the presence of any systematic matrix interference in the analyte/body fluid combinations investigated on the Roche cobas 8000 system. Such findings support the utility of ongoing body fluid validation initiatives conducted to maintain compliance with regulatory requirements. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  4. Uncertainty Modeling for Robustness Analysis of Control Upset Prevention and Recovery Systems

    NASA Technical Reports Server (NTRS)

    Belcastro, Christine M.; Khong, Thuan H.; Shin, Jong-Yeob; Kwatny, Harry; Chang, Bor-Chin; Balas, Gary J.

    2005-01-01

    Formal robustness analysis of aircraft control upset prevention and recovery systems could play an important role in their validation and ultimate certification. Such systems (developed for failure detection, identification, and reconfiguration, as well as upset recovery) need to be evaluated over broad regions of the flight envelope and under extreme flight conditions, and should include various sources of uncertainty. However, formulation of linear fractional transformation (LFT) models for representing system uncertainty can be very difficult for complex parameter-dependent systems. This paper describes a preliminary LFT modeling software tool which uses a matrix-based computational approach that can be directly applied to parametric uncertainty problems involving multivariate matrix polynomial dependencies. Several examples are presented (including an F-16 at an extreme flight condition, a missile model, and a generic example with numerous crossproduct terms), and comparisons are given with other LFT modeling tools that are currently available. The LFT modeling method and preliminary software tool presented in this paper are shown to compare favorably with these methods.

  5. Matrix solid-phase dispersion extraction of organophosphorus pesticide using SiO2-poly(N-vinylimidazole)

    NASA Astrophysics Data System (ADS)

    Gutiérrez-Solís, M. C.; Muñoz-Rodríguez, D.; Medina-Peralta, S.; Carrera-Figueiras, C.; Ávila-Ortega, A.

    2013-06-01

    A sorbent material based on silica particles modified with poly(N-vinylimidazole) (SiO2-PVI) has been evaluated for the treatment of samples by matrix solid-phase dispersion (MSPD). The extraction of four organophosphorus pesticides was done from a spiked tomato and the extracts were analyzed by gas chromatography coupled to mass spectrometry. Six elution solvents were evaluated and acetone was selected due to better recovery of the four pesticides and low background signal in the chromatograms. A factorial design 24 was used for selection of extraction conditions. The factors were contact time, acetone volume, treatment (with or without freeze-drying) and adsorbent (SiO2 or SiO2-PVI). The best recoveries were obtained using 15 minutes of contact, 2 mL of solvent and sorbent without freeze-drying. The recoveries were between 60 and 83% for SiO2-PVI in spiked tomato with 0.2 and 0.8μg/g.

  6. A low-rank matrix recovery approach for energy efficient EEG acquisition for a wireless body area network.

    PubMed

    Majumdar, Angshul; Gogna, Anupriya; Ward, Rabab

    2014-08-25

    We address the problem of acquiring and transmitting EEG signals in Wireless Body Area Networks (WBAN) in an energy efficient fashion. In WBANs, the energy is consumed by three operations: sensing (sampling), processing and transmission. Previous studies only addressed the problem of reducing the transmission energy. For the first time, in this work, we propose a technique to reduce sensing and processing energy as well: this is achieved by randomly under-sampling the EEG signal. We depart from previous Compressed Sensing based approaches and formulate signal recovery (from under-sampled measurements) as a matrix completion problem. A new algorithm to solve the matrix completion problem is derived here. We test our proposed method and find that the reconstruction accuracy of our method is significantly better than state-of-the-art techniques; and we achieve this while saving sensing, processing and transmission energy. Simple power analysis shows that our proposed methodology consumes considerably less power compared to previous CS based techniques.

  7. Substrate modulation of fatty acid effects on energization and respiration of kidney proximal tubules during hypoxia/reoxygenation.

    PubMed

    Bienholz, Anja; Al-Taweel, Ahmad; Roeser, Nancy F; Kribben, Andreas; Feldkamp, Thorsten; Weinberg, Joel M

    2014-01-01

    Kidney proximal tubules subjected to hypoxia/reoxygenation develop a nonesterified fatty acid-induced energetic deficit characterized by persistent partial mitochondrial deenergization that can be prevented and reversed by citric acid cycle substrates. To further assess the role of competition between fatty acids and substrates on inner membrane substrate carriers in the deenergization and the contribution to deenergization of fatty acid effects on respiratory function, digitonin-permeabilized rabbit and mouse tubules were studied using either addition of exogenous oleate after control normoxic incubation or increases of endogenous fatty acids produced by hypoxia/reoxygenation. The results demonstrated major effects of matrix oxaloacetate accumulation on succinate-supported energization and respiration and their modification by fatty acids. Improvements of energization in the presence of fatty acids by glutamate were shown to result predominantly from lowering matrix oxaloacetate rather than from amelioration of transmembrane cycling of fatty acids and uncoupling. Mouse tubules had 2.5 fold higher rates of succinate utilization, which resulted in stronger effects of oxaloacetate accumulation than rabbit tubules. Hypoxia/reoxygenation induced respiratory inhibition that was more severe for complex I-dependent substrates. Fatty acids themselves did not acutely contribute to this respiratory inhibition, but lowering them during 60 min. reoxygenation to allow recovery of ATP during that period alleviated it. These data clarify the basis for the nonesterified fatty acid-induced mitochondrial energetic deficit in kidney proximal tubules that impairs structural and functional recovery and provide insight into interactions that need to be considered in the design of substrate-based interventions to improve mitochondrial function.

  8. Recovery among Adolescents: Models for Post-Treatment Gains in Drug Abuse Treatments

    PubMed Central

    Joe, George W.; Knight, Danica Kalling; Becan, Jennifer E.; Flynn, Patrick M.

    2013-01-01

    Recovery among adolescents undergoing substance abuse treatment was modeled in terms of pre-treatment motivation, therapeutic relationships, psychological functioning, treatment retention, legal pressures, DSM diagnoses, and client demographics. To address between program differences, a within-covariance matrix, based on 547 youth, was used. Applicability of the results across treatment modalities was also examined. The data were from the NIDA-sponsored DATOS Adolescent study. Results from structural equation models (estimated using Mplus) indicated that higher pre-treatment motivation predicted stronger counselor and in-treatment peer relationships, better counselor relationships and retention predicted less illegal drug use at follow-up, and DSM diagnosis was important in the treatment process. Overall, illegal drug use at follow-up was associated with post-treatment alcohol consumption, cigarette use, condom nonuse, psychological distress, criminality, and school non-attendance. The results document the importance of motivation and therapeutic relationships on recovery, even when taking into account the relative effects of legal pressures, DSM diagnoses, and demographics. PMID:24238715

  9. Improved analysis of SP and CoSaMP under total perturbations

    NASA Astrophysics Data System (ADS)

    Li, Haifeng

    2016-12-01

    Practically, in the underdetermined model y= A x, where x is a K sparse vector (i.e., it has no more than K nonzero entries), both y and A could be totally perturbed. A more relaxed condition means less number of measurements are needed to ensure the sparse recovery from theoretical aspect. In this paper, based on restricted isometry property (RIP), for subspace pursuit (SP) and compressed sampling matching pursuit (CoSaMP), two relaxed sufficient conditions are presented under total perturbations to guarantee that the sparse vector x is recovered. Taking random matrix as measurement matrix, we also discuss the advantage of our condition. Numerical experiments validate that SP and CoSaMP can provide oracle-order recovery performance.

  10. 3D Printed Silicones with Shape Memory

    DOE PAGES

    Wu, Amanda S.; Small IV, Ward; Bryson, Taylor M.; ...

    2017-07-05

    Direct ink writing enables the layer-by-layer manufacture of ordered, porous structures whose mechanical behavior is driven by architecture and material properties. Here, we incorporate two different gas filled microsphere pore formers to evaluate the effect of shell stiffness and T g on compressive behavior and compression set in siloxane matrix printed structures. The lower T g microsphere structures exhibit substantial compression set when heated near and above T g, with full structural recovery upon reheating without constraint. By contrast, the higher T g microsphere structures exhibit reduced compression set with no recovery upon reheating. Aside from their role in tuningmore » the mechanical behavior of direct ink write structures, polymer microspheres are good candidates for shape memory elastomers requiring structural complexity, with potential applications toward tandem shape memory polymers.« less

  11. 3D Printed Silicones with Shape Memory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, Amanda S.; Small IV, Ward; Bryson, Taylor M.

    Direct ink writing enables the layer-by-layer manufacture of ordered, porous structures whose mechanical behavior is driven by architecture and material properties. Here, we incorporate two different gas filled microsphere pore formers to evaluate the effect of shell stiffness and T g on compressive behavior and compression set in siloxane matrix printed structures. The lower T g microsphere structures exhibit substantial compression set when heated near and above T g, with full structural recovery upon reheating without constraint. By contrast, the higher T g microsphere structures exhibit reduced compression set with no recovery upon reheating. Aside from their role in tuningmore » the mechanical behavior of direct ink write structures, polymer microspheres are good candidates for shape memory elastomers requiring structural complexity, with potential applications toward tandem shape memory polymers.« less

  12. Detection of Listeria spp. using ACTERO listeria enrichment media.

    PubMed

    Claveau, David; Olishevskyy, Sergiy; Giuffre, Michael; Martinez, Gabriela

    2014-01-01

    ACTERO Listeria Enrichment Media (ACTERO Listeria) is a selective medium developed for a single-step recovery and enrichment of Listeria spp. from environmental samples. Robustness testing of the ACTERO Listeria medium demonstrated good performance when minor changes were introduced to the incubation temperature and time. All 54 Listeria strains tested, representing the most frequently isolated Listeria species from food (L. monocytogenes, L. ivanovii, L. seeligeri, L. welshimeri, and L. grayi), were successfully enriched in ACTERO Listeria. None of the 30 nontarget strains tested in the exclusivity study was recovered after incubation in ACTERO Listeria. Recovery of Listeria was consistent across three independently produced lots of the ACTERO Listeria, and the prepared medium was stable for 45 days when stored at 4 degrees C in the dark. Matrix studies performed with environmental sponge samples from plastic and stainless steel surfaces demonstrated similar recovery of Listeria spp. in a single-step enrichment using ACTERO Listeria from plastic, and significantly better recovery from stainless steel surfaces when compared to the U.S. Department of Agriculture-Food Safety and Inspection Service reference method. The results of this study prove that ACTERO Listeria Enrichment Media can be effectively used in replacement of the two-step enrichment suggested by the reference method without affecting the recovery of Listeria spp. from environmental samples.

  13. Recovery methods for detection and quantification of Campylobacter depend on meat matrices and bacteriological or PCR tools.

    PubMed

    Fosse, J; Laroche, M; Rossero, A; Fédérighi, M; Seegers, H; Magras, C

    2006-09-01

    Campylobacter is one of the main causes of human foodborne bacterial disease associated with meat consumption in developed countries. Therefore, the most effective approach for recovery and detection of Campylobacter from meat should be determined. Two hundred ninety pork skin and chine samples were inoculated with Campylobacter jejuni NCTC 11168 and two strains of Campylobacter coli. Campylobacter cells were then recovered from suspensions and enumerated by direct plating. Campylobacter recovery was evaluated by comparing results for two methods of sample collection (swabbing and mechanical pummeling) and three recovery fluids (peptone water, 5% glucose serum, and demineralized water). End-point multiplex PCR was performed to evaluate the compatibility of the recovery fluids with direct PCR detection techniques. Mean recovery ratios differed significantly between pork skin and chine samples. Ratios were higher for mechanical pummeling (0.53 for pork skin and 0.49 for chine) than for swabbing (0.31 and 0.13, respectively). For pork skin, ratios obtained with peptone water (0.50) and with glucose serum (0.55) were higher than those obtained with demineralized water (0.16). Significant differences were not observed for chine samples. Direct multiplex PCR detection of Campylobacter was possible with pork skin samples. The tools for Campylobacter recovery must be appropriate for the meat matrix to be evaluated. In this study, less than 66% of inoculated Campylobacter was recovered from meat. This underestimation must be taken into account for quantitative risk analysis of Campylobacter infection.

  14. Simultaneous determination of multiclass emerging contaminants in aquatic plants by ultrasound-assisted matrix solid-phase dispersion and GC-MS.

    PubMed

    Aznar, Ramón; Albero, Beatriz; Sánchez-Brunete, Consuelo; Miguel, Esther; Martín-Girela, Isabel; Tadeo, José L

    2017-03-01

    A multiresidue method was developed for the simultaneous determination of 31 emerging contaminants (pharmaceutical compounds, hormones, personal care products, biocides, and flame retardants) in aquatic plants. Analytes were extracted by ultrasound-assisted matrix solid-phase dispersion (UA-MSPD) and determined by gas chromatography-mass spectrometry after sylilation, The method was validated for different aquatic plants (Typha angustifolia, Arundo donax, and Lemna minor) and a semiaquatic cultivated plant (Oryza sativa) with good recoveries at concentrations of 100 and 25 ng g -1 wet weight, ranging from 70 to 120 %, and low method detection limits (0.3 to 2.2 ng g -1 wet weight). A significant difference of the chromatographic response was observed for some compounds in neat solvent versus matrix extracts, and therefore, quantification was carried out using matrix-matched standards in order to overcome this matrix effect. Aquatic plants taken from rivers located at three Spanish regions were analyzed, and the compounds detected were parabens, bisphenol A, benzophenone-3, cyfluthrin, and cypermethrin. The levels found ranged from 6 to 25 ng g -1 wet weight except for cypermethrin that was detected at 235 ng g -1 wet weight in O. sativa samples.

  15. Extraction and quantitative analysis of iodine in solid and solution matrixes.

    PubMed

    Brown, Christopher F; Geiszler, Keith N; Vickerman, Tanya S

    2005-11-01

    129I is a contaminant of interest in the vadose zone and groundwater at numerous federal and privately owned facilities. Several techniques have been utilized to extract iodine from solid matrixes; however, all of them rely on two fundamental approaches: liquid extraction or chemical/heat-facilitated volatilization. While these methods are typically chosen for their ease of implementation, they do not totally dissolve the solid. We defined a method that produces complete solid dissolution and conducted laboratory tests to assess its efficacy to extract iodine from solid matrixes. Testing consisted of potassium nitrate/potassium hydroxide fusion of the sample, followed by sample dissolution in a mixture of sulfuric acid and sodium bisulfite. The fusion extraction method resulted in complete sample dissolution of all solid matrixes tested. Quantitative analysis of 127I and 129I via inductively coupled plasma mass spectrometry showed better than +/-10% accuracy for certified reference standards, with the linear operating range extending more than 3 orders of magnitude (0.005-5 microg/L). Extraction and analysis of four replicates of standard reference material containing 5 microg/g 127I resulted in an average recovery of 98% with a relative deviation of 6%. This simple and cost-effective technique can be applied to solid samples of varying matrixes with little or no adaptation.

  16. Determination of six sulfonamide antibiotics, two metabolites and trimethoprim in wastewater by isotope dilution liquid chromatography/tandem mass spectrometry.

    PubMed

    Le-Minh, Nhat; Stuetz, Richard M; Khan, Stuart J

    2012-01-30

    A highly sensitive method for the analysis of six sulfonamide antibiotics (sulfadiazine, sulfathiazole, sulfapyridine, sulfamerazine, sulfamethazine and sulfamethoxazole), two sulfonamide metabolites (N(4)-acetyl sulfamethazine and N(4)-acetyl sulfamethoxazole) and the commonly co-applied antibiotic trimethoprim was developed for the analysis of complex wastewater samples. The method involves solid phase extraction of filtered wastewater samples followed by liquid chromatography-tandem mass spectral detection. Method detection limits were shown to be matrix-dependent but ranged between 0.2 and 0.4 ng/mL for ultrapure water, 0.4 and 0.7 ng/mL for tap water, 1.4 and 5.9 ng/mL for a laboratory-scale membrane bioreactor (MBR) mixed liquor, 0.7 and 1.7 ng/mL for biologically treated effluent and 0.5 and 1.5 ng/g dry weight for MBR activated sludge. An investigation of analytical matrix effects was undertaken, demonstrating the significant and largely unpredictable nature of signal suppression observed for variably complex matrices compared to an ultrapure water matrix. The results demonstrate the importance of accounting for such matrix effects for accurate quantitation, as done in the presented method by isotope dilution. Comprehensive validation of calibration linearity, reproducibility, extraction recovery, limits of detection and quantification are also presented. Finally, wastewater samples from a variety of treatment stages in a full-scale wastewater treatment plant were analysed to illustrate the effectiveness of the method. Copyright © 2011 Elsevier B.V. All rights reserved.

  17. Proportional plus integral MIMO controller for regulation and tracking with anti-wind-up features

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Puleston, P.F.; Mantz, R.J.

    1993-11-01

    A proportional plus integral matrix control structure for MIMO systems is proposed. Based on a standard optimal control structure with integral action, it permits a greater degree of independence of the design and tuning of the regulating and tracking features, without considerably increasing the controller complexity. Fast recovery from load disturbances is achieved, while large overshoots associated with set-point changes and reset wind-up problems can be reduced. A simple effective procedure for practical tuning is introduced.

  18. Analysis of lethal and sublethal impacts of environmental disasters on sperm whales using stochastic modeling.

    PubMed

    Ackleh, Azmy S; Chiquet, Ross A; Ma, Baoling; Tang, Tingting; Caswell, Hal; Veprauskas, Amy; Sidorovskaia, Natalia

    2017-08-01

    Mathematical models are essential for combining data from multiple sources to quantify population endpoints. This is especially true for species, such as marine mammals, for which data on vital rates are difficult to obtain. Since the effects of an environmental disaster are not fixed, we develop time-varying (nonautonomous) matrix population models that account for the eventual recovery of the environment to the pre-disaster state. We use these models to investigate how lethal and sublethal impacts (in the form of reductions in the survival and fecundity, respectively) affect the population's recovery process. We explore two scenarios of the environmental recovery process and include the effect of demographic stochasticity. Our results provide insights into the relationship between the magnitude of the disaster, the duration of the disaster, and the probability that the population recovers to pre-disaster levels or a biologically relevant threshold level. To illustrate this modeling methodology, we provide an application to a sperm whale population. This application was motivated by the 2010 Deepwater Horizon oil rig explosion in the Gulf of Mexico that has impacted a wide variety of species populations including oysters, fish, corals, and whales.

  19. Matrix precipitation: a general strategy to eliminate matrix interference for pharmaceutical toxic impurities analysis.

    PubMed

    Yang, Xiaojing; Xiong, Xuewu; Cao, Ji; Luan, Baolei; Liu, Yongjun; Liu, Guozhu; Zhang, Lei

    2015-01-30

    Matrix interference, which can lead to false positive/negative results, contamination of injector or separation column, incompatibility between sample solution and the selected analytical instrument, and response inhibition or even quenching, is commonly suffered for the analysis of trace level toxic impurities in drug substance. In this study, a simple matrix precipitation strategy is proposed to eliminate or minimize the above stated matrix interference problems. Generally, a sample of active pharmaceutical ingredients (APIs) is dissolved in an appropriate solvent to achieve the desired high concentration and then an anti-solvent is added to precipitate the matrix substance. As a result, the target analyte is extracted into the mixed solution with very less residual of APIs. This strategy has the characteristics of simple manipulation, high recovery and excellent anti-interference capability. It was found that the precipitation ratio (R, representing the ability to remove matrix substance) and the proportion of solvent (the one used to dissolve APIs) in final solution (P, affecting R and also affecting the method sensitivity) are two important factors of the precipitation process. The correlation between R and P was investigated by performing precipitation with various APIs in different solvent/anti-solvent systems. After a detailed mathematical reasoning process, P=20% was proved to be an effective and robust condition to perform the precipitation strategy. The precipitation method with P=20% can be used as a general strategy for toxic impurity analysis in APIs. Finally, several typical examples are described in this article, where the challenging matrix interference issues have been resolved successfully. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Trace analysis of three fungicides in animal origin foods with a modified QuEChERS method and liquid chromatography-tandem mass spectrometry.

    PubMed

    Mu, Zhaobin; Feng, Xiaoxiao; Zhang, Yun; Zhang, Hongyan

    2016-02-01

    A multi-residue method based on modified QuEChERS (quick, easy, cheap, effective, rugged, and safe) sample preparation, followed by liquid chromatography tandem mass spectrometry (LC-MS/MS), was developed and validated for the determination of three selected fungicides (propiconazole, pyraclostrobin, and isopyrazam) in seven animal origin foods. The overall recoveries at the three spiking levels of 0.005, 0.05, and 0.5 mg kg(-1) spanned between 72.3 and 101.4% with relative standard deviation (RSD) values between 0.7 and 14.9%. The method shows good linearity in the concentrations between 0.001 and 1 mg L(-1) with the coefficient of determination (R (2)) value >0.99 for each target analyte. The limit of detections (LODs) for target analytes were between 0.04 and 1.26 μg kg(-1), and the limit of quantifications (LOQs) were between 0.13 and 4.20 μg kg(-1). The matrix effect for each individual compound was evaluated through the study of ratios of the areas obtained in solvent and matrix standards. The optimized method provided a negligible matrix effect for propiconazole within 20%, whereas for pyraclostrobin and isopyrazam, the matrix effect was relatively significant with a maximum value of 49.8%. The developed method has been successfully applied to the analysis of 210 animal origin samples obtained from 16 provinces of China. The results suggested that the developed method was satisfactory for trace analysis of three fungicides in animal origin foods.

  1. Evaluation of the QuEChERS sample preparation approach for the analysis of pesticide residues in olives.

    PubMed

    Cunha, Sara C; Lehotay, Steven J; Mastovska, Katerina; Fernandes, José O; Beatriz, Maria; Oliveira, P P

    2007-03-01

    This paper describes the use of a quick, easy, cheap, effective, rugged, and safe (QuEChERS) method for extraction and cleanup of 16 pesticide residues of interest in olives and olive oil. These products contain a high lipid content, which can adversely affect pesticide recoveries and harm traditional chromatographic systems. For extraction, the main factors (oil and water content) were studied and optimized in experiments to maximize pesticide recoveries. Dispersive SPE with different sorbents was also investigated to minimize matrix coextractives and interferences. For analysis, a new automated DSI device was tested in GC-MS to avoid nonvolatile coextractives from contaminating the instrument. LC-MS/MS with positive ESI was used for those pesticides that were difficult to detect by GC-MS. The final method was validated for olives in terms of recoveries, repeatabilities, and reproducibilities using both detection techniques. The results demonstrated that the method achieved acceptable quantitative recoveries of 70-109% with RSDs < 20% for DSI-GC-MS and 88-130% with RSDs < 10% for LC-MS/MS, and LOQ at or below the regulatory maximum residue limits for the pesticides were achieved.

  2. Improved measurement of extracellular enzymatic activities in subsurface sediments using competitive desorption treatment

    NASA Astrophysics Data System (ADS)

    Hoarfrost, Adrienne; Snider, Rachel; Arnosti, Carol

    2017-02-01

    Extracellular enzymatic activities initiate microbially-driven heterotrophic carbon cycling in subsurface sediments. While measurement of hydrolytic activities in sediments is fundamental to our understanding of carbon cycling, these measurements are often technically difficult due to sorption of organic substrates to the sediment matrix. Most methods that measure hydrolysis of organic substrates in sediments rely on recovery of a fluorophore or fluorescently-labeled target substrate from a sediment incubation. The tendency for substrates to sorb to sediments results in lower recovery of an added substrate, and can result in data that are unusable or difficult to interpret. We developed a treatment using competitive desorption of a fluorescently-labeled, high molecular weight organic substrate that improves recovery of the labeled substrate from sediment subsamples. Competitive desorption treatment improved recovery of the fluorescent substrate by a median of 66%, expanded the range of sediments for which activity measurements could be made, and was effective in sediments from a broad range of geochemical contexts. More reliable measurements of hydrolytic activities in sediments will yield usable and more easily interpretable data from a wider range of sedimentary environments, enabling better understanding of microbially-catalyzed carbon cycling in subsurface environments.

  3. Platelet-rich fibrin matrix improves wound angiogenesis via inducing endothelial cell proliferation.

    PubMed

    Roy, Sashwati; Driggs, Jason; Elgharably, Haytham; Biswas, Sabyasachi; Findley, Muna; Khanna, Savita; Gnyawali, Urmila; Bergdall, Valerie K; Sen, Chandan K

    2011-11-01

    The economic, social, and public health burden of chronic ulcers and other compromised wounds is enormous and rapidly increasing with the aging population. The growth factors derived from platelets play an important role in tissue remodeling including neovascularization. Platelet-rich plasma (PRP) has been utilized and studied for the last four decades. Platelet gel and fibrin sealant, derived from PRP mixed with thrombin and calcium chloride, have been exogenously applied to tissues to promote wound healing, bone growth, hemostasis, and tissue sealing. In this study, we first characterized recovery and viability of as well as growth factor release from platelets in a novel preparation of platelet gel and fibrin matrix, namely platelet-rich fibrin matrix (PRFM). Next, the effect of PRFM application in a delayed model of ischemic wound angiogenesis was investigated. The study, for the first time, shows the kinetics of the viability of platelet-embedded fibrin matrix. A slow and steady release of growth factors from PRFM was observed. The vascular endothelial growth factor released from PRFM was primarily responsible for endothelial mitogenic response via extracellular signal-regulated protein kinase activation pathway. Finally, this preparation of PRFM effectively induced endothelial cell proliferation and improved wound angiogenesis in chronic wounds, providing evidence of probable mechanisms of action of PRFM in healing of chronic ulcers. 2011 by the Wound Healing Society.

  4. [Study on the determination of trace gallium in molybdenum-coated pyrolytic graphite tube by electrothermal absorption spectrometry].

    PubMed

    Huang, Yu-an; Zhou, Fang-qin; Long, Si-hua; Yang, Liu

    2004-02-01

    The effects on gallium atomization in the pyrolytic graphite tube imposed by different matrix modifiers and different coatings were discussed detailedly in this paper. In the presence of matrix modifier of Ni(NO3)2 the matrix interference was eliminated efficiently. The pyrolytic graphite tubes were coated differently with lanthanum, zirconium, and molybdenum to avoid producing gallium carbide. Results showed that the tube with molybdenum coating was the best. On this basis, the mechanism of gallium atomization in the molybdenum-coated pyrolytic graphite tube using Ni(NO3)2 as a matrix modifier was studied furthermore; in addition, the parameters of the operation were optimized. As a result, a new method improved in many aspects was developed to detect trace gallium in complicated sample of gangue. The outcomes of practical applications indicated that the method could satisfy the requests of analysis and that the manipulations were simple to achieve. The characteristic content, the detection limit, and the adding recoveries were 2.12 x 10(-11) g, 1.4 x 10(-10) g and 97.4%-102.7% respectively, and the relative standard deviation was less than or equal to 3.6% (n = 11).

  5. Multi-residue pesticide analysis (gas chromatography-tandem mass spectrometry detection)-Improvement of the quick, easy, cheap, effective, rugged, and safe method for dried fruits and fat-rich cereals-Benefit and limit of a standardized apple purée calibration (screening).

    PubMed

    Rasche, Claudia; Fournes, Britta; Dirks, Uwe; Speer, Karl

    2015-07-17

    Some steps of the QuEChERS method for the analysis of pesticides with GC-MS/MS in cereals and dried fruits were improved or simplified. For the latter, a mixing vessel with stator-rotor-system proved to be advantageous. The extraction procedure of dried fruits is much easier and safer than the Ultra Turrax and results in excellent validation data at a concentration level of 0.01mg/kg (116 of 118 analytes with recoveries in the range of 70-120%, 117 of 118 analytes with RSD <20%). After qualifying problematic lipophilic pesticides in fat-rich cereals (fat content >7%), predominantly organochlorines showed recoveries of <70% in quantification when the standard QuEChERS method with water was used. A second extraction was carried out analogous to the QuEChERS method, however, without the addition of water. With this simple modification, the problematic lipophilic pesticides, which had been strongly affected by the fat content of the commodities, could be determined with recoveries above 70% even at a concentration level of 0.01mg/kg. Moreover, a GC-MS/MS screening method for 120 pesticides at a concentration level of 0.01mg/kg was established by employing analyte protectants (ethylglycerol, gulonolactone, and sorbitol). The use of only one standardized calibration, made of an apple purée extract in combination with analyte protectants, allowed for a qualitative and quantitative analysis of 120 pesticides in different matrix extracts (tomato, red pepper, sour cherries, dried apples, black currant powder, raisins, wheat flour, rolled oats, wheat germ). The analyte protectants leveled the differences in the matrix-induced protection effect of the analyzed extracts over a wide range. The majority of the pesticides were analyzed with good analytical results (recoveries in the range of 70-120% and RSD <20%). Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Gelatin-thrombin hemostatic matrix in neurosurgical procedures: hemostasis effectiveness and economic value of clinical and surgical procedure-related benefits.

    PubMed

    Esposito, Felice; Cappabianca, Paolo; Angileri, Filippo F; Cavallo, Luigi M; Priola, Stefano M; Crimi, Salvatore; Solari, Domenico; Germanò, Antonino F; Tomasello, Francesco

    2016-07-26

    Gelatin-thrombin hemostatic matrix (FloSeal®) use is associated with shorter surgical times and less blood loss, parameters that are highly valued in neurosurgical procedures. We aimed to assess the effectiveness of gelatin-thrombin in neurosurgical procedures and estimate its economic value. In a 6-month retrospective evaluation at 2 hospitals, intraoperative and postoperative information were collected from patients undergoing neurosurgical procedures where bleeding was controlled with gelatin-thrombin matrix or according to local bleeding control guidelines (control group). Study endpoints were: length of surgery, estimated blood loss, hospitalization duration, blood units utilized, intensive care unit days, postoperative complications, and time-to-recovery. Statistical methods compared endpoints between the gelatin-thrombin and control groups and resource utilization costs were estimated. Seventy-eight patients (38 gelatin-thrombin; 40 control) were included. Gelatin-thrombin was associated with a shorter surgery duration than control 166±40 versus 185±55, p=0.0839); a lower estimated blood loss (185±80 versus 250±95ml; p=0.0017); a shorter hospital stay (10±3 versus 13±3 days; p<0.001); fewer intensive care unit days (10 days/3 patients and 20 days/4 patients); and shorter time-to-recovery (3±2.2 versus 4±2.8 weeks; p=0861). Fewer gelatin-thrombin patients experienced postoperative complications (3 minor) than the control group (5 minor; 3 major). No gelatin-thrombin patient required blood transfusion; 5 units were administered in the control group. The cost of gelatin-thrombin (€268.40/unit) was offset by the shorter surgery duration (difference of 19 minutes at €858 per hour) and the economic value of improved the other endpoint outcomes (ie, shorter hospital stay, less blood loss/lack of need for transfusion, fewer intensive care unit days, and complications). Gelatin-thrombin hemostatic matrix use in patients undergoing neurosurgical procedures was associated with better intra- and post-operative parameters than conventional hemostasis methods, with these parameters having substantial economic benefits.

  7. Determination of 18 kinds of trace impurities in the vanadium battery grade vanadyl sulfate by ICP-OES

    NASA Astrophysics Data System (ADS)

    Yong, Cheng

    2018-03-01

    The method that direct determination of 18 kinds of trace impurities in the vanadium battery grade vanadyl sulfate by inductively coupled plasma atomic emission spectrometry (ICP-OES) was established, and the detection range includes 0.001% ∼ 0.100% of Fe, Cr, Ni, Cu, Mn, Mo, Pb, As, Co, P, Ti, Zn and 0.005% ∼ 0.100% of K, Na, Ca, Mg, Si, Al. That the influence of the matrix effects, spectral interferences and background continuum superposition in the high concentrations of vanadium ions and sulfate coexistence system had been studied, and then the following conclusions were obtained: the sulfate at this concentration had no effect on the determination, but the matrix effects or continuous background superposition which were generated by high concentration of vanadium ions had negative interference on the determination of potassium and sodium, and it produced a positive interference on the determination of the iron and other impurity elements, so that the impacts of high vanadium matrix were eliminated by the matrix matching and combining synchronous background correction measures. Through the spectral interference test, the paper classification summarized the spectral interferences of vanadium matrix and between the impurity elements, and the analytical lines, the background correction regions and working parameters of the spectrometer were all optimized. The technical performance index of the analysis method is that the background equivalent concentration -0.0003%(Na)~0.0004%(Cu), the detection limit of the element is 0.0001%∼ 0.0003%, RSD<10% when the element content is in the range from 0.001% to 0.007%, RSD< 20% even if the element content is in the range from 0.0001% to 0.001% that is beyond the scope of the method of detection, recoveries is 91.0% ∼ 110.0%.

  8. USDA FSIS, FDA BAM, and ISO culture methods BD BBL CHROMagar O157 media.

    PubMed

    Ritter, Vicki; Kircher, Susan; Dick, Nancy

    2009-01-01

    BBL CHROMagar O157 media (CO) was evaluated for detection of Escherichia coli O157:H7 in raw ground beef and unpasteurized apple cider. The recovery of E. coli O157:H7 on CO was compared to the U.S. Food and Drug Administration (FDA) Bacteriological Analytical Manual (BAM), U.S. Department of Agriculture (USDA) Food Safety and Inspection Service (FSIS), and International Organization for Standardization (ISO) reference-plated media using the recommended enrichment broths. Of the 180 food samples tested, 45 were tested using BAM, 45 using the USDA method, and 90 using the ISO method. CO produced comparable results with the reference methods on all matrixes with a sensitivity of 100% and a specificity of 100%. No false negatives were found in testing the food matrixes. There was no statistical difference in recovery based on Chi-square analysis. Method agreement for raw ground beef was 85% for the USDAFSIS method and 95% for the ISO method. Method agreement for unpasteurized apple cider was 100% for the ISO and FDA BAM methods. In all cases where method agreement was <100%, CO detected more positives than the reference method media. Evaluation of known isolates on CO in inclusivity and exclusivity testing had a sensitivity and specificity of 100%. The results of this study demonstrate that CO is an effective medium for the recovery and detection of E. coli O157:H7 in raw ground beef and unpasteurized apple cider using FDA BAM, USDA FSIS, and ISO methods.

  9. Assessment of the Influence of Soil Characteristics and Hydrocarbon Fuel Cocontamination on the Solvent Extraction of Perfluoroalkyl and Polyfluoroalkyl Substances.

    PubMed

    Mejia-Avendaño, Sandra; Munoz, Gabriel; Sauvé, Sébastien; Liu, Jinxia

    2017-02-21

    Sites impacted by the use of aqueous film-forming foams (AFFFs) present elevated concentrations of perfluoroalkyl and polyfluoroalkyl substances (PFAS). The characterization of the PFAS contamination at such sites may be greatly complicated by the presence of hydrocarbon cocontaminants and by the large variety of PFAS potentially present in AFFFs. In order to further a more comprehensive characterization of AFFF-contaminated soils, the solvent extraction of PFAS from soil was studied under different conditions. Specifically, the impact of soil properties (textural class, organic matter content) and the presence of hydrocarbon contamination (supplemented in the form of either diesel or crude oil) on PFAS recovery performance was evaluated for two extraction methods [methanol/sodium hydroxide (MeOH/NaOH) and methanol/ammonium hydroxide (MeOH/NH 4 OH)]. While both methods performed satisfactorily for perfluoroalkyl acids and fluorotelomer sulfonates, the extraction of newly identified surfactants with functionalities such as betaine and quaternary ammonium was improved with the MeOH/NaOH based method. The main factors that were found to influence the extraction efficiency were the soil properties; a high organic matter or clay content was observed to negatively affect the recovery of the newly identified compounds. While the MeOH/NaOH solvent yielded more efficient recovery rates overall, it also entailed the disadvantage of presenting higher detection limits and substantial matrix effects at the instrumental analysis stage, requiring matrix-matched calibration curves. The results discussed herein bear important implications for a more comprehensive and reliable environmental monitoring of PFAS components at AFFF-impacted sites.

  10. Functional connectivity analysis in resting state fMRI with echo-state networks and non-metric clustering for network structure recovery

    NASA Astrophysics Data System (ADS)

    Wismüller, Axel; DSouza, Adora M.; Abidin, Anas Z.; Wang, Xixi; Hobbs, Susan K.; Nagarajan, Mahesh B.

    2015-03-01

    Echo state networks (ESN) are recurrent neural networks where the hidden layer is replaced with a fixed reservoir of neurons. Unlike feed-forward networks, neuron training in ESN is restricted to the output neurons alone thereby providing a computational advantage. We demonstrate the use of such ESNs in our mutual connectivity analysis (MCA) framework for recovering the primary motor cortex network associated with hand movement from resting state functional MRI (fMRI) data. Such a framework consists of two steps - (1) defining a pair-wise affinity matrix between different pixel time series within the brain to characterize network activity and (2) recovering network components from the affinity matrix with non-metric clustering. Here, ESNs are used to evaluate pair-wise cross-estimation performance between pixel time series to create the affinity matrix, which is subsequently subject to non-metric clustering with the Louvain method. For comparison, the ground truth of the motor cortex network structure is established with a task-based fMRI sequence. Overlap between the primary motor cortex network recovered with our model free MCA approach and the ground truth was measured with the Dice coefficient. Our results show that network recovery with our proposed MCA approach is in close agreement with the ground truth. Such network recovery is achieved without requiring low-pass filtering of the time series ensembles prior to analysis, an fMRI preprocessing step that has courted controversy in recent years. Thus, we conclude our MCA framework can allow recovery and visualization of the underlying functionally connected networks in the brain on resting state fMRI.

  11. Simultaneous spectrophotometric determination of glimepiride and pioglitazone in binary mixture and combined dosage form using chemometric-assisted techniques

    NASA Astrophysics Data System (ADS)

    El-Zaher, Asmaa A.; Elkady, Ehab F.; Elwy, Hanan M.; Saleh, Mahmoud Abo El Makarim

    2017-07-01

    In the present work, pioglitazone and glimepiride, 2 widely used antidiabetics, were simultaneously determined by a chemometric-assisted UV-spectrophotometric method which was applied to a binary synthetic mixture and a pharmaceutical preparation containing both drugs. Three chemometric techniques - Concentration residual augmented classical least-squares (CRACLS), principal component regression (PCR), and partial least-squares (PLS) were implemented by using the synthetic mixtures containing the two drugs in acetonitrile. The absorbance data matrix corresponding to the concentration data matrix was obtained by the measurements of absorbencies in the range between 215 and 235 nm in the intervals with Δλ = 0.4 nm in their zero-order spectra. Then, calibration or regression was obtained by using the absorbance data matrix and concentration data matrix for the prediction of the unknown concentrations of pioglitazone and glimepiride in their mixtures. The described techniques have been validated by analyzing synthetic mixtures containing the two drugs showing good mean recovery values lying between 98 and 100%. In addition, accuracy and precision of the three methods have been assured by recovery values lying between 98 and 102% and R.S.D. % ˂0.6 for intra-day precision and ˂1.2 for inter-day precision. The proposed chemometric techniques were successfully applied to a pharmaceutical preparation containing a combination of pioglitazone and glimepiride in the ratio of 30: 4, showing good recovery values. Finally, statistical analysis was carried out to add a value to the verification of the proposed methods. It was carried out by an intrinsic comparison between the 3 chemometric techniques and by comparing values of present methods with those obtained by implementing reference pharmacopeial methods for each of pioglitazone and glimepiride.

  12. Wurtzite/zinc-blende electronic-band alignment in basal-plane stacking faults in semi-polar GaN

    NASA Astrophysics Data System (ADS)

    Monavarian, Morteza; Hafiz, Shopan; Izyumskaya, Natalia; Das, Saikat; Özgür, Ümit; Morkoç, Hadis; Avrutin, Vitaliy

    2016-02-01

    Heteroepitaxial semipolar and nonpolar GaN layers often suffer from high densities of extended defects including basal plane stacking faults (BSFs). BSFs which are considered as inclusions of cubic zinc-blende phase in wurtzite matrix act as quantum wells strongly affecting device performance. Band alignment in BSFs has been discussed as type of band alignment at the wurtzite/zinc blende interface governs the response in differential transmission; fast decay after the pulse followed by slow recovery due to spatial splitting of electrons and heavy holes for type- II band alignment in contrast to decay with no recovery in case of type I band alignment. Based on the results, band alignment is demonstrated to be of type II in zinc-blende segments in wurtzite matrix as in BSFs.

  13. Determination of statin drugs in hospital effluent with dispersive liquid-liquid microextraction and quantification by liquid chromatography.

    PubMed

    Martins, Ayrton F; Frank, Carla da S; Altissimo, Joseline; de Oliveira, Júlia A; da Silva, Daiane S; Reichert, Jaqueline F; Souza, Darliana M

    2017-08-24

    Statins are classified as being amongst the most prescribed agents for treating hypercholesterolaemia and preventing vascular diseases. In this study, a rapid and effective liquid chromatography method, assisted by diode array detection, was designed and validated for the simultaneous quantification of atorvastatin (ATO) and simvastatin (SIM) in hospital effluent samples. The solid phase extraction (SPE) of the analytes was optimized regarding sorbent material and pH, and the dispersive liquid-liquid microextraction (DLLME), in terms of pH, ionic strength, type and volume of extractor/dispersor solvents. The performance of both extraction procedures was evaluated in terms of linearity, quantification limits, accuracy (recovery %), precision and matrix effects for each analyte. The methods proved to be linear in the concentration range considered; the quantification limits were 0.45 µg L -1 for ATO and 0.75 µg L -1 for SIM; the matrix effect was almost absent in both methods and the average recoveries remained between 81.5-90.0%; and the RSD values were <20%. The validated methods were applied to the quantification of the statins in real samples of hospital effluent; the concentrations ranged from 18.8 µg L -1 to 35.3 µg L -1 for ATO, and from 30.3 µg L -1 to 38.5 µg L -1 for SIM. Since the calculated risk quotient was ≤192, the occurrence of ATO and SIM in hospital effluent poses a potential serious risk to human health and the aquatic ecosystem.

  14. A rapid method for the sequential separation of polonium, plutonium, americium and uranium in drinking water.

    PubMed

    Lemons, B; Khaing, H; Ward, A; Thakur, P

    2018-06-01

    A new sequential separation method for the determination of polonium and actinides (Pu, Am and U) in drinking water samples has been developed that can be used for emergency response or routine water analyses. For the first time, the application of TEVA chromatography column in the sequential separation of polonium and plutonium has been studied. This method utilizes a rapid Fe +3 co-precipitation step to remove matrix interferences, followed by plutonium oxidation state adjustment to Pu 4+ and an incubation period of ~ 1 h at 50-60 °C to allow Po 2+ to oxidize to Po 4+ . The polonium and plutonium were then separated on a TEVA column, while separation of americium from uranium was performed on a TRU column. After separation, polonium was micro-precipitated with copper sulfide (CuS), while actinides were micro co-precipitated using neodymium fluoride (NdF 3 ) for counting by the alpha spectrometry. The method is simple, robust and can be performed quickly with excellent removal of interferences, high chemical recovery and very good alpha peak resolution. The efficiency and reliability of the procedures were tested by using spiked samples. The effect of several transition metals (Cu 2+ , Pb 2+ , Fe 3+ , Fe 2+ , and Ni 2+ ) on the performance of this method were also assessed to evaluate the potential matrix effects. Studies indicate that presence of up to 25 mg of these cations in the samples had no adverse effect on the recovery or the resolution of polonium alpha peaks. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. Development of analytical methodologies to assess recalcitrant pesticide bioremediation in biobeds at laboratory scale.

    PubMed

    Rivero, Anisleidy; Niell, Silvina; Cerdeiras, M Pía; Heinzen, Horacio; Cesio, María Verónica

    2016-06-01

    To assess recalcitrant pesticide bioremediation it is necessary to gradually increase the complexity of the biological system used in order to design an effective biobed assembly. Each step towards this effective biobed design needs a suitable, validated analytical methodology that allows a correct evaluation of the dissipation and bioconvertion. Low recovery yielding methods could give a false idea of a successful biodegradation process. To address this situation, different methods were developed and validated for the simultaneous determination of endosulfan, its main three metabolites, and chlorpyrifos in increasingly complex matrices where the bioconvertor basidiomycete Abortiporus biennis could grow. The matrices were culture media, bran, and finally a laboratory biomix composed of bran, peat and soil. The methodology for the analysis of the first evaluated matrix has already been reported. The methodologies developed for the other two systems are presented in this work. The targeted analytes were extracted from fungi growing over bran in semisolid media YNB (Yeast Nitrogen Based) with acetonitrile using shaker assisted extraction, The salting-out step was performed with MgSO4 and NaCl, and the extracts analyzed by GC-ECD. The best methodology was fully validated for all the evaluated analytes at 1 and 25mgkg(-1) yielding recoveries between 72% and 109% and RSDs <11% in all cases. The application of this methodology proved that A. biennis is able to dissipate 94% of endosulfan and 87% of chlorpyrifos after 90 days. Having assessed that A. biennis growing over bran can metabolize the studied pesticides, the next step faced was the development and validation of an analytical procedure to evaluate the analytes in a laboratory scale biobed composed of 50% of bran, 25% of peat and 25% of soil together with fungal micelium. From the different procedures assayed, only ultrasound assisted extraction with ethyl acetate allowed recoveries between 80% and 110% with RSDs <18%. Linearity, recovery, precision, matrix effect and LODs/LOQs of each method were studied for all the analytes: endosulfan isomers (α & β) and its metabolites (endosulfan sulfate, ether and diol) as well as for chlorpyrifos. In the first laboratory evaluation of these biobeds endosulfan was bioconverted up to 87% and chlorpyrifos more than 79% after 27 days. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Flexural creep behavior of epoxy/cotton composite materials before and after saline absorption for orthopedics applications

    NASA Astrophysics Data System (ADS)

    Kontaxis, L. C.; Georgali, A.; Portan, D. V.; Papanicolaou, G. C.

    2018-02-01

    In the present study, epoxy resin-non-woven cotton fibers fabric composite plates were manufactured by using the vacuum infusion technique. Next, flexural creep-recovery experiments were performed in order to study the viscoelastic behavior of both the neat resin and the composite material manufactured under both dry and wet conditions. A low cost, mechanically operated flexural creep testing machine was designed and manufactured according to ASTM standards, for providing an economical means of performing flexural creep experiments. Initially, specimens were immersed in physiological saline for different periods of time at constant temperature of 37°C and subsequently tested under flexural creep conditions in order to study the effect of saline absorption on the creep-recovery behavior of the composites. The specific environmental conditions were chosen such as to simulate the real conditions existed into the human body. The combined effect of applied stress, time of immersion, creep time and amount of saline absorbed on the overall flexural viscoelastic behavior of composites was studied. The maximum amount of saline absorbed by the composites was 3.2%, which is double the saline intake of pure resin. It is believed that the 1.5% extra saline was absorbed into the now formed interphase between the matrix and the hydrophobic cotton fibers. It was observed that the creep strain increases as the immersion time increases. This is believed to occur because of the cumulative effect of absorbed saline from the fibers, the matrix, as well as from the fiber-matrix interphase resulting in the fiber matrix debonding and easier relaxation of the macromolecules at higher moisture contents leading to larger deformations at longer times. However, it should be noted that the strain levels of the epoxy resin/cotton fibers fabric composites, never surpassed those of the pure resin, indicating that the fabric successfully reinforces the composite even under the immersion of the latter in saline. Finally, experimental results were fitted using Burger's model and a detailed analysis of the model and the variation of the four characteristic parameters describing the model with time of immersion is given. Several interesting results were derived which are useful for the future application of the cotton - epoxy composites in medical applications such as in orthopedics.

  17. Determination of cyflumetofen residue in water, soil, and fruits by modified quick, easy, cheap, effective, rugged, and safe method coupled to gas chromatography/tandem mass spectrometry.

    PubMed

    Li, Minmin; Liu, Xingang; Dong, Fengshou; Xu, Jun; Qin, Dongmei; Zheng, Yongquan

    2012-10-01

    A new, highly sensitive, and selective method was developed for the determination of the cyflumetofen residue in water, soil, and fruits by using gas chromatography quadruple mass spectrometry. The target compound was extracted using acetonitrile and then cleaned up using dispersive solid-phase extraction with primary and secondary amine and graphitized carbon black, and optionally by a freezing-out cleanup step. The matrix-matched standards gave satisfactory recoveries and relative standard deviation values in different matrices at three fortified levels (0.05, 0.5, and 1.0 mg kg(-1) ). The overall average recoveries for this method in water, soil, and all fruits matrix at three fortified levels ranged from 76.3 to 101.5% with relative standard deviations in the range of 1.2-11.8% (n = 5). The calculated limits of detection and quantification were typically below 0.005 and 0.015 μg kg(-1), which were much lower than the maximum residue levels established by Japanese Positive List. This study provides a theoretical basis for China to draw up maximum residue level and analytical method for cyflumetofen acaricide in different fruits. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. A novel deep learning algorithm for incomplete face recognition: Low-rank-recovery network.

    PubMed

    Zhao, Jianwei; Lv, Yongbiao; Zhou, Zhenghua; Cao, Feilong

    2017-10-01

    There have been a lot of methods to address the recognition of complete face images. However, in real applications, the images to be recognized are usually incomplete, and it is more difficult to realize such a recognition. In this paper, a novel convolution neural network frame, named a low-rank-recovery network (LRRNet), is proposed to conquer the difficulty effectively inspired by matrix completion and deep learning techniques. The proposed LRRNet first recovers the incomplete face images via an approach of matrix completion with the truncated nuclear norm regularization solution, and then extracts some low-rank parts of the recovered images as the filters. With these filters, some important features are obtained by means of the binaryzation and histogram algorithms. Finally, these features are classified with the classical support vector machines (SVMs). The proposed LRRNet method has high face recognition rate for the heavily corrupted images, especially for the images in the large databases. The proposed LRRNet performs well and efficiently for the images with heavily corrupted, especially in the case of large databases. Extensive experiments on several benchmark databases demonstrate that the proposed LRRNet performs better than some other excellent robust face recognition methods. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Matrix Recipes for Hard Thresholding Methods

    DTIC Science & Technology

    2012-11-07

    have been proposed to approximate the solution. In [11], Donoho et al . demonstrate that, in the sparse approximation problem, under basic incoherence...inducing convex surrogate ‖ · ‖1 with provable guarantees for unique signal recovery. In the ARM problem, Fazel et al . [12] identified the nuclear norm...sparse recovery for all. Technical report, EPFL, 2011 . [25] N. Halko , P. G. Martinsson, and J. A. Tropp. Finding structure with randomness: Probabilistic

  20. Optimization of Immobilized Gallium (III) Ion Affinity Chromatography for Selective Binding and Recovery of Phosphopeptides from Protein Digests

    PubMed Central

    Aryal, Uma K.; Olson, Douglas J.H.; Ross, Andrew R.S.

    2008-01-01

    Although widely used in proteomics research for the selective enrichment of phosphopeptides from protein digests, immobilized metal-ion affinity chromatography (IMAC) often suffers from low specificity and differential recovery of peptides carrying different numbers of phosphate groups. By systematically evaluating and optimizing different loading, washing, and elution conditions, we have developed an efficient and highly selective procedure for the enrichment of phosphopeptides using a commercially available gallium(III)-IMAC column (PhosphoProfile, Sigma). Phosphopeptide enrichment using the reagents supplied with the column is incomplete and biased toward the recovery and/or detection of smaller, singly phosphorylated peptides. In contrast, elution with base (0.4 M ammonium hydroxide) gives efficient and balanced recovery of both singly and multiply phosphorylated peptides, while loading peptides in a strong acidic solution (1% trifluoracetic acid) further increases selectivity toward phosphopeptides, with minimal carryover of nonphosphorylated peptides. 2,5-Dihydroxybenzoic acid, a matrix commonly used when analyzing phosphopeptides by matrix-assisted laser desorption/ionization mass spectrometry was also evaluated as an additive in loading and eluting solvents. Elution with 50% acetonitrile containing 20 mg/mL dihydroxybenzoic acid and 1% phosphoric acid gave results similar to those obtained using ammonium hydroxide as the eluent, although the latter showed the highest specificity for phosphorylated peptides. PMID:19183793

  1. Ultra-high-performance liquid chromatography-Time-of-flight high resolution mass spectrometry to quantify acidic drugs in wastewater.

    PubMed

    Becerra-Herrera, Mercedes; Honda, Luis; Richter, Pablo

    2015-12-04

    A novel analytical approach involving an improved rotating-disk sorptive extraction (RDSE) procedure and ultra-high-performance liquid chromatography (UHPLC) coupled to an ultraspray electrospray ionization source (UESI) and time-of-flight mass spectrometry (TOF/MS), in trap mode, was developed to identify and quantify four non-steroidal anti-inflammatory drugs (NSAIDs) (naproxen, ibuprofen, ketoprofen and diclofenac) and two anti-cholesterol drugs (ACDs) (clofibric acid and gemfibrozil) that are widely used and typically found in water samples. The method reduced the amount of both sample and reagents used and also the time required for the whole analysis, resulting in a reliable and green analytical strategy. The analytical eco-scale was calculated, showing that this methodology is an excellent green analysis, increasing its ecological worth. The detection limits (LOD) and precision (%RSD) were lower than 90ng/L and 10%, respectively. Matrix effects and recoveries were studied using samples from the influent of a wastewater treatment plant (WWTP). All the compounds exhibited suppression of their signals due to matrix effects, and the recoveries were approximately 100%. The applicability and reliability of this methodology were confirmed through the analysis of influent and effluent samples from a WWTP in Santiago, Chile, obtaining concentrations ranging from 1.1 to 20.5μg/L and from 0.5 to 8.6μg/L, respectively. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. A Simple and Fast Extraction Method for the Determination of Multiclass Antibiotics in Eggs Using LC-MS/MS.

    PubMed

    Wang, Kun; Lin, Kunde; Huang, Xinwen; Chen, Meng

    2017-06-21

    The purpose of this study was to develop and validate a simple, fast, and specific extraction method for the analysis of 64 antibiotics from nine classes (including sulfonamides, quinolones, tetracyclines, macrolides, lincosamide, nitrofurans, β-lactams, nitromidazoles, and cloramphenicols) in chicken eggs. Briefly, egg samples were simply extracted with a mixture of acetonitrile-water (90:10, v/v) and 0.1 mol·L -1 Na 2 EDTA solution assisted with ultrasonic. The extract was centrifuged, condensed, and directly analyzed on a liquid chromatography coupled to tandem mass spectrometry. Compared with conventional cleanup methods (passing through solid phase extract cartridges), the established method demonstrated comparable efficiencies in eliminating matrix effects and higher or equivalent recoveries for most of the target compounds. Typical validation parameters including specificity, linearity, matrix effect, limits of detection (LODs) and quantification (LOQs), the decision limit, detection capability, trueness, and precision were evaluated. The recoveries of target compounds ranged from 70.8% to 116.1% at three spiking levels (5, 20, and 50 μg·kg -1 ), with relative standard deviations less than 14%. LODs and LOQs were in the ranges of 0.005-2.00 μg·kg -1 and 0.015-6.00 μg·kg -1 for all of the antibiotics, respectively. A total of five antibiotics were successfully detected in 22 commercial eggs from local markets. This work suggests that the method is suitable for the analysis of multiclass antibiotics in eggs.

  3. Development and validation of sensitive LC/MS/MS method for quantitative bioanalysis of levonorgestrel in rat plasma and application to pharmacokinetics study.

    PubMed

    Ananthula, Suryatheja; Janagam, Dileep R; Jamalapuram, Seshulatha; Johnson, James R; Mandrell, Timothy D; Lowe, Tao L

    2015-10-15

    Rapid, sensitive, selective and accurate LC/MS/MS method was developed for quantitative determination of levonorgestrel (LNG) in rat plasma and further validated for specificity, linearity, accuracy, precision, sensitivity, matrix effect, recovery efficiency and stability. Liquid-liquid extraction procedure using hexane:ethyl acetate mixture at 80:20 v:v ratio was employed to efficiently extract LNG from rat plasma. Reversed phase Luna column C18(2) (50×2.0mm i.d., 3μM) installed on a AB SCIEX Triple Quad™ 4500 LC/MS/MS system was used to perform chromatographic separation. LNG was identified within 2min with high specificity. Linear calibration curve was drawn within 0.5-50ng·mL(-1) concentration range. The developed method was validated for intra-day and inter-day accuracy and precision whose values fell in the acceptable limits. Matrix effect was found to be minimal. Recovery efficiency at three quality control (QC) concentrations 0.5 (low), 5 (medium) and 50 (high) ng·mL(-1) was found to be >90%. Stability of LNG at various stages of experiment including storage, extraction and analysis was evaluated using QC samples, and the results showed that LNG was stable at all the conditions. This validated method was successfully used to study the pharmacokinetics of LNG in rats after SubQ injection, providing its applicability in relevant preclinical studies. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. [A Simultaneous Determination Method with Acetonitrile-n-Hexane Partitioning and Solid-Phase Extraction for Pesticide Residues in Livestock and Marine Products by GC-MS].

    PubMed

    Yoshizaki, Mayuko; Kobayashi, Yukari; Shimizu, Masanori; Maruyama, Kouichi

    2015-01-01

    A simultaneous determination method was examined for 312 pesticides (including isomers) in muscle of livestock and marine products by GC-MS. The pesticide residues extracted from samples with acetone and n-hexane were purified by acetonitrile-n-hexane partitioning, and C18 and SAX/PSA solid-phase extraction without using GPC. Matrix components such as cholesterol were effectively removed. In recovery tests performed by this method using pork, beef, chicken and shrimp, 237-257 pesticides showed recoveries within the range of 70-120% in each sample. Validity was confirmed for 214 of the target pesticides by means of a validation test using pork. In comparison with the Japanese official method using GPC, the treatment time of samples and the quantity of solvent were reduced substantially.

  5. Effect of carbon nanotube functionalization on mechanical and thermal properties of cross-linked epoxy-carbon nanotube nanocomposites: role of strengthening the interfacial interactions.

    PubMed

    Khare, Ketan S; Khabaz, Fardin; Khare, Rajesh

    2014-05-14

    We have used amido-amine functionalized carbon nanotubes (CNTs) that form covalent bonds with cross-linked epoxy matrices to elucidate the role of the matrix-filler interphase in the enhancement of mechanical and thermal properties in these nanocomposites. For the base case of nanocomposites of cross-linked epoxy and pristine single-walled CNTs, our previous work (Khare, K. S.; Khare, R. J. Phys. Chem. B 2013, 117, 7444-7454) has shown that weak matrix-filler interactions cause the interphase region in the nanocomposite to be more compressible. Furthermore, because of the weak matrix-filler interactions, the nanocomposite containing dispersed pristine CNTs has a glass transition temperature (Tg) that is ∼66 K lower than the neat polymer. In this work, we demonstrate that in spite of the presence of stiff CNTs in the nanocomposite, the Young's modulus of the nanocomposite containing dispersed pristine CNTs is virtually unchanged compared to the neat cross-linked epoxy. This observation suggests that the compressibility of the matrix-filler interphase interferes with the ability of the CNTs to reinforce the matrix. Furthermore, when the compressibility of the interphase is reduced by the use of amido-amine functionalized CNTs, the mechanical reinforcement due to the filler is more effective, resulting in a ∼50% increase in the Young's modulus compared to the neat cross-linked epoxy. Correspondingly, the functionalization of the CNTs also led to a recovery in the Tg making it effectively the same as the neat polymer and also resulted in a ∼12% increase in the thermal conductivity of the nanocomposite containing functionalized CNTs compared to that containing pristine CNTs. These results demonstrate that the functionalization of the CNTs facilitates the transfer of both mechanical load and thermal energy across the matrix-filler interface.

  6. Ultrasonic Monitoring of the Interaction between Cement Matrix and Alkaline Silicate Solution in Self-Healing Systems.

    PubMed

    Ait Ouarabi, Mohand; Antonaci, Paola; Boubenider, Fouad; Gliozzi, Antonio S; Scalerandi, Marco

    2017-01-07

    Alkaline solutions, such as sodium, potassium or lithium silicates, appear to be very promising as healing agents for the development of encapsulated self-healing concretes. However, the evolution of their mechanical and acoustic properties in time has not yet been completely clarified, especially regarding their behavior and related kinetics when they are used in the form of a thin layer in contact with a hardened cement matrix. This study aims to monitor, using linear and nonlinear ultrasonic methods, the evolution of a sodium silicate solution interacting with a cement matrix in the presence of localized cracks. The ultrasonic inspection via linear methods revealed that an almost complete recovery of the elastic and acoustic properties occurred within a few days of healing. The nonlinear ultrasonic measurements contributed to provide further insight into the kinetics of the recovery due to the presence of the healing agent. A good regain of mechanical performance was ascertained through flexural tests at the end of the healing process, confirming the suitability of sodium silicate as a healing agent for self-healing cementitious systems.

  7. Thermal single-well injection-withdrawal tracer tests for determining fracture-matrix heat transfer area

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pruess, K.; Doughty, C.

    2010-01-15

    Single-well injection-withdrawal (SWIW) tracer tests involve injection of traced fluid and subsequent tracer recovery from the same well, usually with some quiescent time between the injection and withdrawal periods. SWIW are insensitive to variations in advective processes that arise from formation heterogeneities, because upon withdrawal, fluid parcels tend to retrace the paths taken during injection. However, SWIW are sensitive to diffusive processes, such as diffusive exchange of conservative or reactive solutes between fractures and rock matrix. This paper focuses on SWIW tests in which temperature itself is used as a tracer. Numerical simulations demonstrate the sensitivity of temperature returns tomore » fracture-matrix interaction. We consider thermal SWIW response to the two primary reservoir improvements targeted with stimulation, (1) making additional fractures accessible to injected fluids, and (2) increasing the aperture and permeability of pre-existing fractures. It is found that temperature returns in SWIW tests are insensitive to (2), while providing a strong signal of more rapid temperature recovery during the withdrawal phase for (1).« less

  8. Development and validation of a solid phase extraction sample cleanup procedure for the recovery of trace levels of nitro-organic explosives in soil.

    PubMed

    Thomas, Jennifer L; Donnelly, Christopher C; Lloyd, Erin W; Mothershead, Robert F; Miller, Mark L

    2018-03-01

    An improved cleanup method has been developed for the recovery of trace levels of 12 nitro-organic explosives in soil, which is important not only for the forensic community, but also has environmental implications. A wide variety of explosives or explosive-related compounds were evaluated, including nitramines, nitrate esters, nitroaromatics, and a nitroalkane. Fortified soil samples were extracted with acetone, processed via solid phase extraction (SPE), and then analyzed by gas chromatography with electron capture detection. The following three SPE sorbents in cartridge format were compared: Empore™ SDB-XC, Oasis ® HLB, and Bond Elut NEXUS cartridges. The NEXUS cartridges provided the best overall recoveries for the 12 explosives in potting soil (average 48%) and the fastest processing times (<30min). It also rejected matrix components from spent motor oil on potting soil. The SPE method was validated by assessing limit of detection (LOD), processed sample stability, and interferences. All 12 compounds were detectable at 0.02μg explosive/gram of soil or lower in the three matrices tested (potting soil, sand, and loam) over three days. Seven explosives were stable up to seven days at 2μg/g and three were stable at 0.2μg/g, both in processed loam, which was the most challenging matrix. In the interference study, five interferences above the determined LOD for soil were detected in matrices collected across the United States and in purchased all-purpose sand, potting soil, and loam. This represented a 3.2% false positive rate for the 13 matrices processed by the screening method for interferences. The reported SPE cleanup method provides a fast and simple extraction process for separating organic explosives from matrix components, facilitating sample throughput and reducing instrument maintenance. In addition, a comparison study of the validated SPE method versus conventional syringe filtration was completed and highlighted the benefits of sample cleanup for removing matrix interferences, while also providing lower supply cost, order of magnitude lower LODs for most explosives, higher percent recoveries for complex matrices, and fewer instrument maintenance issues. Published by Elsevier B.V.

  9. Data-Driven Sampling Matrix Boolean Optimization for Energy-Efficient Biomedical Signal Acquisition by Compressive Sensing.

    PubMed

    Wang, Yuhao; Li, Xin; Xu, Kai; Ren, Fengbo; Yu, Hao

    2017-04-01

    Compressive sensing is widely used in biomedical applications, and the sampling matrix plays a critical role on both quality and power consumption of signal acquisition. It projects a high-dimensional vector of data into a low-dimensional subspace by matrix-vector multiplication. An optimal sampling matrix can ensure accurate data reconstruction and/or high compression ratio. Most existing optimization methods can only produce real-valued embedding matrices that result in large energy consumption during data acquisition. In this paper, we propose an efficient method that finds an optimal Boolean sampling matrix in order to reduce the energy consumption. Compared to random Boolean embedding, our data-driven Boolean sampling matrix can improve the image recovery quality by 9 dB. Moreover, in terms of sampling hardware complexity, it reduces the energy consumption by 4.6× and the silicon area by 1.9× over the data-driven real-valued embedding.

  10. Physical aging effects on the compressive linear viscoelastic creep of IM7/K3B composite

    NASA Technical Reports Server (NTRS)

    Veazie, David R.; Gates, Thomas S.

    1995-01-01

    An experimental study was undertaken to establish the viscoelastic behavior of 1M7/K3B composite in compression at elevated temperature. Creep compliance, strain recovery and the effects of physical aging on the time dependent response was measured for uniaxial loading at several isothermal conditions below the glass transition temperature (T(g)). The IM7/K3B composite is a graphite reinforced thermoplastic polyimide with a T(g) of approximately 240 C. In a composite, the two matrix dominated compliance terms associated with time dependent behavior occur in the transverse and shear directions. Linear viscoelasticity was used to characterize the creep/recovery behavior and superposition techniques were used to establish the physical aging related material constants. Creep strain was converted to compliance and measured as a function of test time and aging time. Results included creep compliance master curves, physical aging shift factors and shift rates. The description of the unique experimental techniques required for compressive testing is also given.

  11. Optical ptychographic microscopy for quantitative anisotropic phase imaging

    NASA Astrophysics Data System (ADS)

    Anthony, N.; Cadenazzi, G.; Nugent, K. A.; Abbey, B.

    2016-12-01

    Ptychography has recently been adapted for the recovery of the complete Jones matrix of an anisotropic specimen, using a vectorial form of the Ptychographic Iterative Engine (vPIE) for a set of linearly polarized probes. Here we show that this method can be applied to the recovery of the in-plane components of the elastic strain tensor in a diametrically compressed disc. The advantages and disadvantages of vPIE for the recovery of strain information from `real-world' samples is discussed as well as the potential for this approach to be applied to the characterization of the mechanical properties of optically transparent materials

  12. Coarse-grained simulation of molecular mechanisms of recovery in thermally activated shape-memory polymers

    NASA Astrophysics Data System (ADS)

    Abberton, Brendan C.; Liu, Wing Kam; Keten, Sinan

    2013-12-01

    Thermally actuated shape-memory polymers (SMPs) are capable of being programmed into a temporary shape and then recovering their permanent reference shape upon exposure to heat, which facilitates a phase transition that allows dramatic increase in molecular mobility. Experimental, analytical, and computational studies have established empirical relations of the thermomechanical behavior of SMPs that have been instrumental in device design. However, the underlying mechanisms of the recovery behavior and dependence on polymer microstructure remain to be fully understood for copolymer systems. This presents an opportunity for bottom-up studies through molecular modeling; however, the limited time-scales of atomistic simulations prohibit the study of key performance metrics pertaining to recovery. In order to elucidate the effects of phase fraction, recovery temperature, and deformation temperature on shape recovery, here we investigate the shape-memory behavior in a copolymer model with coarse-grained potentials using a two-phase molecular model that reproduces physical crosslinking. Our simulation protocol allows observation of upwards of 90% strain recovery in some cases, at time-scales that are on the order of the timescale of the relevant relaxation mechanism (stress relaxation in the unentangled soft-phase). Partial disintegration of the glassy phase during mechanical deformation is found to contribute to irrecoverable strain. Temperature dependence of the recovery indicates nearly full elastic recovery above the trigger temperature, which is near the glass-transition temperature of the rubbery switching matrix. We find that the trigger temperature is also directly correlated with the deformation temperature, indicating that deformation temperature influences the recovery temperatures required to obtain a given amount of shape recovery, until the plateau regions overlap above the transition region. Increasing the fraction of glassy phase results in higher strain recovery at low to intermediate temperatures, a widening of the transition region, and an eventual crossover at high temperatures. Our results corroborate experimental findings on shape-memory behavior and provide new insight into factors governing deformation recovery that can be leveraged in biomaterials design. The established computational methodology can be extended in straightforward ways to investigate the effects of monomer chemistry, low-molecular-weight solvents, physical and chemical crosslinking, different phase-separation morphologies, and more complicated mechanical deformation toward predictive modeling capabilities for stimuli-responsive polymers.

  13. Liquid chromatography/electrospray ionization/isotopic dilution mass spectrometry analysis of n-(phosphonomethyl) glycine and mass spectrometry analysis of aminomethyl phosphonic acid in environmental water and vegetation matrixes.

    PubMed

    Grey, L; Nguyen, B; Yang, P

    2001-01-01

    A liquid chromatography/electrospray/mass spectrometry (LC/ES/MS) method was developed for the analysis of glyphosate (n-phosphonomethyl glycine) and its metabolite, aminomethyl phosphonic acid (AMPA) using isotope-labelled glyphosate as a method surrogate. Optimized parameters were achieved to derivatize glyphosate and AMPA using 9-fluorenylmethyl chloroformate (FMOC-Cl) in borate buffer prior to a reversed-phase LC analysis. Method spike recovery data obtained using laboratory and real world sample matrixes indicated an excellent correlation between the recovery of the native and isotope-labelled glyphosate. Hence, the first performance-based, isotope dilution MS method with superior precision, accuracy, and data quality was developed for the analysis of glyphosate. There was, however, no observable correlation between the isotope-labelled glyphosate and AMPA. Thus, the use of this procedure for the accurate analysis of AMPA was not supported. Method detection limits established using standard U.S. Environmental Protection Agency protocol were 0.06 and 0.30 microg/L, respectively, for glyphosate and AMPA in water matrixes and 0.11 and 0.53 microg/g, respectively, in vegetation matrixes. Problems, solutions, and the method performance data related to the analysis of chlorine-treated drinking water samples are discussed. Applying this method to other environmental matrixes, e.g., soil, with minimum modifications is possible, assuring accurate, multimedia studies of glyphosate concentration in the environment and the delivery of useful multimedia information for regulatory applications.

  14. Developing analytical approaches to explore the connection between endocrine-active pharmaceuticals in water to effects in fish

    USGS Publications Warehouse

    Jones-Lepp, Tammy L.; Taniguchi-Fu, Randi L.; Morgan, Jade; Nance Jr., Trevor; Ward, Matthew; Alvarez, David A.; Mills, Lesley

    2015-01-01

    The emphasis of this research project was to develop and optimize a solid-phase extraction method and highperformance liquid chromatography-electrospray ionizationmass spectrometry method, such that a linkage between the detection of endocrine-active pharmaceuticals (EAPs) in the aquatic environment and subsequent effects on fish populations could eventually be studied. Four EAPs were studied: tamoxifen (TAM), exemestane (EXE), letrozole (LET), anastrozole (ANA); and three TAM metabolites: 4- hydroxytamoxifen, e/z endoxifen, and n-desmethyl tamoxifen. In aqueous matrices, the use of isotopically labeled standards for the EAPs allowed for the generation of good recoveries, greater than 80 %, and low relative standard deviations (% RSDs) (3 to 27 %). TAM metabolites had lower recoveries in the spiked water matrices: 35 to 93 % in waste/source water compared to 58 to 110 % in DI water. The precision in DI water was acceptable ranging from 8 to 38 % RSD. However, the precision in real environmental wastewaters could be poor, ranging from 15 to 120 % RSD, dependent upon unique matrix effects. In plasma, the overall recoveries of the EAPs were acceptable: 88 to 110 %, with %RSDs of 6 to 18 % (Table 3). The spiked recoveries of the TAM metabolites from plasma were good, ranging from 77 to 120 %, with %RSDs ranging from 27 to 32 %. Two of the TAM metabolites, 4- hydroxytamoxifen and n-desmethyl tamoxifen, were confirmed in most of the environmental aqueous samples. The discovery of TAM metabolites demonstrates that the source of the TAM metabolites, TAM, is constant, introducing a pseudo-persistence of this chemical into the environment.

  15. Determination of sulfonamides in animal tissues by modified QuEChERS and liquid chromatography tandem mass spectrometry.

    PubMed

    Wen, Ching-Hsuan; Lin, Shu-Ling; Fuh, Ming-Ren

    2017-03-01

    In this study, the salting-out solvent extraction and dispersive solid-phase extraction (dSPE) clean-up steps in QuEChERS (quick, easy, cheap, effective, rugged, and safe) method were optimized to reduce matrix effect and efficiently extract target sulfonamides from a variety of edible animal tissues. The extracted sulfonamides were then analyzed using liquid chromatography tandem mass spectrometry (LC-MS/MS). Good extraction recoveries (74.0-100.3% in five different sources of animal tissues; n=3) with acceptable matrix effect (<10%, except for liver samples) were obtained using the proposed method. For the first time, a commercial ND-lipids cartridge was used to remove hydrophobic matrix components from fat-rich animal tissues in the clean-up step of QuEChERS. In addition, good linearity (0.125-12.5ngg -1 ) was observed using matrix-matched calibration (in beef). Limits of detection (LODs) were estimated at 0.01-0.03ngg -1 in beef, pork, and chicken samples. For beef tripe and pig liver samples, the LODs were in the range of 0.02-0.04ngg -1 . Good intra-day/inter-day precision (1.0-10.5%/0.4-8.0%) and accuracy (95.2-107.2%/97.8-102.1%) were also achieved using the modified QuEChERS for sample pretreatment. The applicability of the modified QuEChERS-LC-MS/MS method was demonstrated by determining the occurrence of target sulfonamides in various edible animal tissues for potential food safety analysis. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Determination of microcystin-LR in drinking water using UPLC tandem mass spectrometry-matrix effects and measurement.

    PubMed

    Li, Wei; Duan, Jinming; Niu, Chaoying; Qiang, Naichen; Mulcahy, Dennis

    2011-10-01

    A simple detection method using ultra-performance liquid chromatography electrospray ionisation tandem mass spectrometry (UPLC-ESI-MS-MS) coupled with the sample dilution method for determining trace microcystin-LR (MC-LR) in drinking water is presented. The limit of detection (LOD) was 0.04 µg/L and the limit of quantitation (LOQ) was 0.1 µg/L. Water matrix effects of ionic strength, dissolved organic carbon (DOC) and pH were examined. The results indicate that signal detection intensity for MC-LR was significantly suppressed as the ionic strength increased from ultrapure water condition, whereas it increased slightly with solution pH and DOC at low concentrations. However, addition of methanol (MeOH) into the sample was able to counter the signal suppression effects. In this study, dilution of the tap water sample by adding 4% MeOH (v/v) was observed to be adequate to compensate for the signal suppression. The recoveries of the samples fortified with MC-LR (0.2, 1, and 10 µg/L) for three different tap water samples ranged from 84.4% to 112.9%.

  17. Matrix Metalloproteinases as a Therapeutic Target to Improve Neurologic Recovery After Spinal Cord Injury

    DTIC Science & Technology

    2015-12-01

    aberrant remodeling of the bladder wall, which could contribute to increased weight of this structure and reduced voiding. We next evaluated the...moderate levels of SCI show both neurological and urological recovery. Task 4. Analysis of lesion epicenter and serotonergic fiber tracks caudal to a...SCI in mice. 4a. Perfuse animals with fixative, remove the cords, and stain with Eriochrome cyanine or immunostain for serotonergic fiber tracks

  18. Petz recovery versus matrix reconstruction

    NASA Astrophysics Data System (ADS)

    Holzäpfel, Milan; Cramer, Marcus; Datta, Nilanjana; Plenio, Martin B.

    2018-04-01

    The reconstruction of the state of a multipartite quantum mechanical system represents a fundamental task in quantum information science. At its most basic, it concerns a state of a bipartite quantum system whose subsystems are subjected to local operations. We compare two different methods for obtaining the original state from the state resulting from the action of these operations. The first method involves quantum operations called Petz recovery maps, acting locally on the two subsystems. The second method is called matrix (or state) reconstruction and involves local, linear maps that are not necessarily completely positive. Moreover, we compare the quantities on which the maps employed in the two methods depend. We show that any state that admits Petz recovery also admits state reconstruction. However, the latter is successful for a strictly larger set of states. We also compare these methods in the context of a finite spin chain. Here, the state of a finite spin chain is reconstructed from the reduced states of a few neighbouring spins. In this setting, state reconstruction is the same as the matrix product operator reconstruction proposed by Baumgratz et al. [Phys. Rev. Lett. 111, 020401 (2013)]. Finally, we generalize both these methods so that they employ long-range measurements instead of relying solely on short-range correlations embodied in such local reduced states. Long-range measurements enable the reconstruction of states which cannot be reconstructed from measurements of local few-body observables alone and hereby we improve existing methods for quantum state tomography of quantum many-body systems.

  19. An Improved Compressive Sensing and Received Signal Strength-Based Target Localization Algorithm with Unknown Target Population for Wireless Local Area Networks.

    PubMed

    Yan, Jun; Yu, Kegen; Chen, Ruizhi; Chen, Liang

    2017-05-30

    In this paper a two-phase compressive sensing (CS) and received signal strength (RSS)-based target localization approach is proposed to improve position accuracy by dealing with the unknown target population and the effect of grid dimensions on position error. In the coarse localization phase, by formulating target localization as a sparse signal recovery problem, grids with recovery vector components greater than a threshold are chosen as the candidate target grids. In the fine localization phase, by partitioning each candidate grid, the target position in a grid is iteratively refined by using the minimum residual error rule and the least-squares technique. When all the candidate target grids are iteratively partitioned and the measurement matrix is updated, the recovery vector is re-estimated. Threshold-based detection is employed again to determine the target grids and hence the target population. As a consequence, both the target population and the position estimation accuracy can be significantly improved. Simulation results demonstrate that the proposed approach achieves the best accuracy among all the algorithms compared.

  20. Effect of aspect ratio and deformability on nanoparticle extravasation through nanopores.

    PubMed

    Kersey, Farrell R; Merkel, Timothy J; Perry, Jillian L; Napier, Mary E; DeSimone, Joseph M

    2012-06-12

    We describe the fabrication of filamentous hydrogel nanoparticles using a unique soft lithography based particle molding process referred to as PRINT (particle replication in nonwetting templates). The nanoparticles possess a constant width of 80 nm, and we varied their lengths ranging from 180 to 5000 nm. In addition to varying the aspect ratio of the particles, the deformability of the particles was tuned by varying the cross-link density within the particle matrix. Size characteristics such as hydrodynamic diameter and persistence length of the particles were analyzed using dynamic light scattering and electron microscopy techniques, respectively, while particle deformability was assessed by atomic force microscopy. Additionally, the ability of the particles to pass through membranes containing 0.2 μm pores was assessed by means of a simple filtration technique, and particle recovery was determined using fluorescence spectroscopy. The results show that particle recovery is mostly independent of aspect ratio at all cross-linker concentrations utilized, with the exception of 96 wt % PEG diacrylate 80 × 5000 nm particles, which showed the lowest percent recovery.

  1. Use of phenyl/tetrazolyl-functionalized magnetic microspheres and stable isotope labeled internal standards for significant reduction of matrix effect in determination of nine fluoroquinolones by liquid chromatography-quadrupole linear ion trap mass spectrometry.

    PubMed

    Xu, Fei; Liu, Feng; Wang, Chaozhan; Wei, Yinmao

    2018-02-01

    In this study, the strategy of unique adsorbent combined with isotope labeled internal standards was used to significantly reduce the matrix effect for the enrichment and analysis of nine fluoroquinolones in a complex sample by liquid chromatography coupled to quadrupole linear ion trap mass spectrometry (LC-QqQ LIT -MS/MS). The adsorbent was prepared conveniently by functionalizing Fe 3 O 4 @SiO 2 microspheres with phenyl and tetrazolyl groups, which could adsorb fluoroquinolones selectively via hydrophobic, electrostatic, and π-π interactions. The established magnetic solid-phase extraction (MSPE) method as well as using stable isotope labeled internal standards in the next MS/MS detection was able to reduce the matrix effect significantly. In the process of LC-QqQ LIT -MS/MS analysis, the precursor and product ions of the analytes were monitored quantitatively and qualitatively on a QTrap system equipped simultaneously with the multiple reaction monitoring (MRM) and enhanced product ion (EPI) scan. Subsequently, the enrichment method combined with LC-QqQ LIT -MS/MS demonstrated good analytical features in terms of linearity (7.5-100.0 ng mL -1 , r > 0.9960), satisfactory recoveries (88.6%-118.3%) with RSDs < 12.0%, LODs = 0.5 μg kg -1 and LOQs = 1.5 μg kg -1 for all tested analytes. Finally, the developed MSPE-LC-QqQ LIT -MS/MS method had been successfully applied to real pork samples for food-safety risk monitoring in Ningxia Province, China. Graphical abstract Mechanism of reducing matrix effect through the as-prepared adsorbent.

  2. Structured Modeling and Analysis of Stochastic Epidemics with Immigration and Demographic Effects

    PubMed Central

    Baumann, Hendrik; Sandmann, Werner

    2016-01-01

    Stochastic epidemics with open populations of variable population sizes are considered where due to immigration and demographic effects the epidemic does not eventually die out forever. The underlying stochastic processes are ergodic multi-dimensional continuous-time Markov chains that possess unique equilibrium probability distributions. Modeling these epidemics as level-dependent quasi-birth-and-death processes enables efficient computations of the equilibrium distributions by matrix-analytic methods. Numerical examples for specific parameter sets are provided, which demonstrates that this approach is particularly well-suited for studying the impact of varying rates for immigration, births, deaths, infection, recovery from infection, and loss of immunity. PMID:27010993

  3. Structured Modeling and Analysis of Stochastic Epidemics with Immigration and Demographic Effects.

    PubMed

    Baumann, Hendrik; Sandmann, Werner

    2016-01-01

    Stochastic epidemics with open populations of variable population sizes are considered where due to immigration and demographic effects the epidemic does not eventually die out forever. The underlying stochastic processes are ergodic multi-dimensional continuous-time Markov chains that possess unique equilibrium probability distributions. Modeling these epidemics as level-dependent quasi-birth-and-death processes enables efficient computations of the equilibrium distributions by matrix-analytic methods. Numerical examples for specific parameter sets are provided, which demonstrates that this approach is particularly well-suited for studying the impact of varying rates for immigration, births, deaths, infection, recovery from infection, and loss of immunity.

  4. Determination of human-use pharmaceuticals in filtered water by direct aqueous injection: high-performance liquid chromatography/tandem mass spectrometry

    USGS Publications Warehouse

    Furlong, Edward T.; Noriega, Mary C.; Kanagy, Christopher J.; Kanagy, Leslie K.; Coffey, Laura J.; Burkhardt, Mark R.

    2014-01-01

    This report describes a method for the determination of 110 human-use pharmaceuticals using a 100-microliter aliquot of a filtered water sample directly injected into a high-performance liquid chromatograph coupled to a triple-quadrupole tandem mass spectrometer using an electrospray ionization source operated in the positive ion mode. The pharmaceuticals were separated by using a reversed-phase gradient of formic acid/ammonium formate-modified water and methanol. Multiple reaction monitoring of two fragmentations of the protonated molecular ion of each pharmaceutical to two unique product ions was used to identify each pharmaceutical qualitatively. The primary multiple reaction monitoring precursor-product ion transition was quantified for each pharmaceutical relative to the primary multiple reaction monitoring precursor-product transition of one of 19 isotope-dilution standard pharmaceuticals or the pesticide atrazine, using an exact stable isotope analogue where possible. Each isotope-dilution standard was selected, when possible, for its chemical similarity to the unlabeled pharmaceutical of interest, and added to the sample after filtration but prior to analysis. Method performance for each pharmaceutical was determined for reagent water, groundwater, treated drinking water, surface water, treated wastewater effluent, and wastewater influent sample matrixes that this method will likely be applied to. Each matrix was evaluated in order of increasing complexity to demonstrate (1) the sensitivity of the method in different water matrixes and (2) the effect of sample matrix, particularly matrix enhancement or suppression of the precursor ion signal, on the quantitative determination of pharmaceutical concentrations. Recovery of water samples spiked (fortified) with the suite of pharmaceuticals determined by this method typically was greater than 90 percent in reagent water, groundwater, drinking water, and surface water. Correction for ambient environmental concentrations of pharmaceuticals hampered the determination of absolute recoveries and method sensitivity of some compounds in some water types, particularly for wastewater effluent and influent samples. The method detection limit of each pharmaceutical was determined from analysis of pharmaceuticals fortified at multiple concentrations in reagent water. The calibration range for each compound typically spanned three orders of magnitude of concentration. Absolute sensitivity for some compounds, using isotope-dilution quantitation, ranged from 0.45 to 94.1 nanograms per liter, primarily as a result of the inherent ionization efficiency of each pharmaceutical in the electrospray ionization process. Holding-time studies indicate that acceptable recoveries of pharmaceuticals can be obtained from filtered water samples held at 4 °C for as long as 9 days after sample collection. Freezing samples to provide for storage for longer periods currently (2014) is under evaluation by the National Water Quality Laboratory.

  5. Standard addition with internal standardisation as an alternative to using stable isotope labelled internal standards to correct for matrix effects-Comparison and validation using liquid chromatography-​tandem mass spectrometric assay of vitamin D.

    PubMed

    Hewavitharana, Amitha K; Abu Kassim, Nur Sofiah; Shaw, Paul Nicholas

    2018-06-08

    With mass spectrometric detection in liquid chromatography, co-eluting impurities affect the analyte response due to ion suppression/enhancement. Internal standard calibration method, using co-eluting stable isotope labelled analogue of each analyte as the internal standard, is the most appropriate technique available to correct for these matrix effects. However, this technique is not without drawbacks, proved to be expensive because separate internal standard for each analyte is required, and the labelled compounds are expensive or require synthesising. Traditionally, standard addition method has been used to overcome the matrix effects in atomic spectroscopy and was a well-established method. This paper proposes the same for mass spectrometric detection, and demonstrates that the results are comparable to those with the internal standard method using labelled analogues, for vitamin D assay. As conventional standard addition procedure does not address procedural errors, we propose the inclusion of an additional internal standard (not co-eluting). Recoveries determined on human serum samples show that the proposed method of standard addition yields more accurate results than the internal standardisation using stable isotope labelled analogues. The precision of the proposed method of standard addition is superior to the conventional standard addition method. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Paracrine Potential of the Human Adipose Tissue-Derived Stem Cells to Modulate Balance between Matrix Metalloproteinases and Their Inhibitors in the Osteoarthritic Cartilage In Vitro

    PubMed Central

    Bagdonas, Edvardas; Kusleviciute, Ilona; Mackiewicz, Zygmunt; Unguryte, Ausra; Porvaneckas, Narunas; Fleury, Sandrine; Venalis, Algirdas

    2017-01-01

    Adipose tissue represents an abundant source of stem cells. Along with anti-inflammatory effects, ASC secrete various factors that may modulate metabolism of extracellular matrix in osteoarthritic (OA) cartilage, suggesting that the presence of ASC could be advantageous for OA cartilage due to the recovery of homeostasis between matrix metalloproteinases (MMPs) and their tissue inhibitors of metalloproteinases (TIMPs). To evaluate these effects, cartilage explants (CE) were cocultured with ASC for 3 and 7 days under stimulation with or without IL-1β. The pattern of gene expression in CE was modified by ASC, including the upregulation of COL1A1 and COL3A1 and the downregulation of MMP13 and COL10A1. The production of MMP-1, MMP-3, and MMP-13 by ASC was not significant; moreover, cocultures with ASC reduced MMP-13 production in CE. In conclusion, active production of TIMP-1, TIMP-2, TIMP-3, IL-6, IL-8, and gelatinases MMP-2 and MMP-9 by ASC may be involved in the extracellular matrix remodelling, as indicated by the altered expression of collagens, the downregulated production of MMP-13, and the reduced chondrocyte apoptosis in the cocultured CE. These data suggest that ASC modulated homeostasis of MMPs/TIMPs in degenerated OA cartilage in vitro and might be favourable in case of the intra-articular application of ASC therapy for the treatment of OA. PMID:28819366

  7. [Simultaneous determination of pyraclostrobin and thiophanate-methyl and its metabolite carbendazim residues in soil and citrus by QuEChERS-liquid chromatography- tandem mass spectrometry].

    PubMed

    Li, Fuqin; Shi, Lihong; Wang, Fei; Sun, Caiyuan; Kang, Di; Zhang, Yuping; Chen, Lingzhu; Hu, Deyu

    2017-06-08

    A QuEChERS-liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the determination of pyraclostrobin, thiophanate-methyl and its metabolite carbendazim in soil and citrus. The samples were extracted with methanol or acetonitrile, purified by primary secondary amine (PSA), then separated by LC, detected in multiple reaction monitoring (MRM) mass spectrometry mode via positive electrospray ionization. The analytes were quantified by matrix-matched standard solutions with external standard method. The limits of quantification (LOQs) of pyraclostrobin, thiophanate-methyl and carbendazim in different matrices were 5.8-7.0 μg/kg, 9.3-14.1 μg/kg and 2.1-2.6 μg/kg, respectively. For all the samples, the spiked recoveries ranged from 75.48% to 109.18%, and the relative standard deviations (RSDs) were 0.60%-5.11% ( n =5). The method is quick, easy, effective, sensitive and accurate. The matrix-matched calibration solutions can efficiently compensate matrix effects of the pyraclostrobin, thiophanate-methyl and carbendazim in LC-MS/MS analysis. The established method can be applied to the residue analysis of the real samples of soil, citrus peel, citrus pulp and citrus fruits.

  8. Fast and Simple Analytical Method for Direct Determination of Total Chlorine Content in Polyglycerol by ICP-MS.

    PubMed

    Jakóbik-Kolon, Agata; Milewski, Andrzej; Dydo, Piotr; Witczak, Magdalena; Bok-Badura, Joanna

    2018-02-23

    The fast and simple method for total chlorine determination in polyglycerols using low resolution inductively coupled plasma mass spectrometry (ICP-MS) without the need for additional equipment and time-consuming sample decomposition was evaluated. Linear calibration curve for 35 Cl isotope in the concentration range 20-800 µg/L was observed. Limits of detection and quantification equaled to 15 µg/L and 44 µg/L, respectively. This corresponds to possibility of detection 3 µg/g and determination 9 µg/g of chlorine in polyglycerol using studied conditions (0.5% matrix-polyglycerol samples diluted or dissolved with water to an overall concentration of 0.5%). Matrix effects as well as the effect of chlorine origin have been evaluated. The presence of 0.5% (m/m) of matrix species similar to polyglycerol (polyethylene glycol-PEG) did not influence the chlorine determination for PEGs with average molecular weights (MW) up to 2000 Da. Good precision and accuracy of the chlorine content determination was achieved regardless on its origin (inorganic/organic). High analyte recovery level and low relative standard deviation values were observed for real polyglycerol samples spiked with chloride. Additionally, the Combustion Ion Chromatography System was used as a reference method. The results confirmed high accuracy and precision of the tested method.

  9. Adaptive OFDM Waveform Design for Spatio-Temporal-Sparsity Exploited STAP Radar

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sen, Satyabrata

    In this chapter, we describe a sparsity-based space-time adaptive processing (STAP) algorithm to detect a slowly moving target using an orthogonal frequency division multiplexing (OFDM) radar. The motivation of employing an OFDM signal is that it improves the target-detectability from the interfering signals by increasing the frequency diversity of the system. However, due to the addition of one extra dimension in terms of frequency, the adaptive degrees-of-freedom in an OFDM-STAP also increases. Therefore, to avoid the construction a fully adaptive OFDM-STAP, we develop a sparsity-based STAP algorithm. We observe that the interference spectrum is inherently sparse in the spatio-temporal domain,more » as the clutter responses occupy only a diagonal ridge on the spatio-temporal plane and the jammer signals interfere only from a few spatial directions. Hence, we exploit that sparsity to develop an efficient STAP technique that utilizes considerably lesser number of secondary data compared to the other existing STAP techniques, and produces nearly optimum STAP performance. In addition to designing the STAP filter, we optimally design the transmit OFDM signals by maximizing the output signal-to-interference-plus-noise ratio (SINR) in order to improve the STAP performance. The computation of output SINR depends on the estimated value of the interference covariance matrix, which we obtain by applying the sparse recovery algorithm. Therefore, we analytically assess the effects of the synthesized OFDM coefficients on the sparse recovery of the interference covariance matrix by computing the coherence measure of the sparse measurement matrix. Our numerical examples demonstrate the achieved STAP-performance due to sparsity-based technique and adaptive waveform design.« less

  10. Matrix elimination method for the determination of precious metals in ores using electrothermal atomic absorption spectrometry.

    PubMed

    Salih, Bekir; Celikbiçak, Omür; Döker, Serhat; Doğan, Mehmet

    2007-03-28

    Poly(N-(hydroxymethyl)methacrylamide)-1-allyl-2-thiourea) hydrogels, poly(NHMMA-ATU), were synthesized by gamma radiation using (60)Co gamma source in the ternary mixture of NHMMA-ATU-H(2)O. These hydrogels were used for the specific gold, silver, platinum and palladium recovery, pre-concentration and matrix elimination from the solutions containing trace amounts of precious metal ions. Elimination of inorganic matrices such as different transition and heavy metal ions, and anions was performed by adjusting the solution pH to 0.5 that was the selective adsorption pH of the precious metal ions. Desorption of the precious metal ions was performed by using 0.8 M thiourea in 3M HCl as the most efficient desorbing agent with recovery values more than 95%. In the desorption medium, thiourea effect on the atomic signal was eliminated by selecting proper pyrolysis and atomization temperatures for all precious metal ions. Precision and the accuracy of the results were improved in the graphite furnace-atomic absorption spectrometer (GFAAS) measurements by applying the developed matrix elimination method performing the adsorption at pH 0.5. Pre-concentration factors of the studied precious metal ions were found to be at least 1000-fold. Detection limits of the precious metal ions were found to be less than 10 ng L(-1) of the all studied precious metal ions by using the proposed pre-concentration method. Determination of trace levels of the precious metals in the sea-water, anode slime, geological samples and photographic fixer solutions were performed using GFAAS clearly after applying the adsorption-desorption cycle onto the poly(NHMMA-UTU) hydrogels.

  11. CTEPP NC DATA QA/QC RESULTS

    EPA Science Inventory

    This data set contains the method performance results. This includes field blanks, method blanks, duplicate samples, analytical duplicates, matrix spikes, and surrogate recovery standards.

    The Children’s Total Exposure to Persistent Pesticides and Other Persistent Pollutant (...

  12. Separation and Enrichment of Gold in Water, Geological and Environmental Samples by Solid Phase Extraction on Multiwalled Carbon Nanotubes Prior to its Determination by Flame Atomic Absorption Spectrometry.

    PubMed

    Duran, Ali; Tuzen, Mustafa; Soylak, Mustafa

    2015-01-01

    This study proposes the application of multi-walled carbon nanotubes as a solid sorbent for the preconcentration of gold prior to its flame atomic absorption spectrometry determination. Extraction was achieved by using a glass column (15.0 cm in length and 1.0 cm in diameter). Quantitative recoveries were obtained in the pH range of 2.5-4.0; the elution step was carried out with 5.0 ml of 1.0 mol/L HNO3 in acetone. In the ligand-free study, variables such as pH, eluent type, sample volume, flow rates, and matrix effect were examined for the optimum recovery of gold ions. The gold ions were able to be pre-concentrated by a factor of 150 and their LOD was determined to be 1.71 μg/L. In order to evaluate the accuracy of the developed method, addition-recovery tests were applied for the tap water, mineral water, and sea water samples. Gold recovery studies were implemented using a wet digestion technique for mine and soil samples taken from various media, and this method was also applied for anodic slime samples taken from the factories located in the Kayseri Industrial Zone of Turkey.

  13. Fibrin matrix for suspension of regenerative cells in an artificial nerve conduit.

    PubMed

    Kalbermatten, D F; Kingham, P J; Mahay, D; Mantovani, C; Pettersson, J; Raffoul, W; Balcin, H; Pierer, G; Terenghi, G

    2008-06-01

    Peripheral nerve injury presents with specific problems of neuronal reconstructions, and from a clinical viewpoint a tissue engineering approach would facilitate the process of repair and regeneration. We have previously used artificial nerve conduits made from bioresorbable poly-3-hydroxybutyrate (PHB) in order to refine the ways in which peripheral nerves are repaired and reconnected to the target muscles and skin. The addition of Schwann cells (SC) or differentiated mesenchymal stem cells (dMSC) to the conduits enhances regeneration. In this study, we have used a matrix based on fibrin (Tisseel) to fill optimally the nerve-conduits with cells. In vitro analysis showed that both SC and MSC adhered significantly better to PHB in the presence of fibrin and cells continued to maintain their differentiated state. Cells were more optimally distributed throughout the conduit when seeded in fibrin than by delivery in growth medium alone. Transplantation of the nerve conduits in vivo showed that cells in combination with fibrin matrix significantly increased nerve regeneration distance (using PGP9.5 and S100 distal and proximal immunohistochemistry) when compared with empty PHB conduits. This study shows the beneficial combinatory effect of an optimised matrix, cells and conduit material as a step towards bridging nerve gaps which should ultimately lead to improved functional recovery following nerve injury.

  14. Probabilistic homogenization of random composite with ellipsoidal particle reinforcement by the iterative stochastic finite element method

    NASA Astrophysics Data System (ADS)

    Sokołowski, Damian; Kamiński, Marcin

    2018-01-01

    This study proposes a framework for determination of basic probabilistic characteristics of the orthotropic homogenized elastic properties of the periodic composite reinforced with ellipsoidal particles and a high stiffness contrast between the reinforcement and the matrix. Homogenization problem, solved by the Iterative Stochastic Finite Element Method (ISFEM) is implemented according to the stochastic perturbation, Monte Carlo simulation and semi-analytical techniques with the use of cubic Representative Volume Element (RVE) of this composite containing single particle. The given input Gaussian random variable is Young modulus of the matrix, while 3D homogenization scheme is based on numerical determination of the strain energy of the RVE under uniform unit stretches carried out in the FEM system ABAQUS. The entire series of several deterministic solutions with varying Young modulus of the matrix serves for the Weighted Least Squares Method (WLSM) recovery of polynomial response functions finally used in stochastic Taylor expansions inherent for the ISFEM. A numerical example consists of the High Density Polyurethane (HDPU) reinforced with the Carbon Black particle. It is numerically investigated (1) if the resulting homogenized characteristics are also Gaussian and (2) how the uncertainty in matrix Young modulus affects the effective stiffness tensor components and their PDF (Probability Density Function).

  15. Determination of cocaine in postmortem human liver exposed to overdose. Application of an innovative and efficient extraction/clean up procedure and gas chromatography-mass spectrometry analysis.

    PubMed

    Magalhães, Elisângela Jaqueline; Ribeiro de Queiroz, Maria Eliana Lopes; Penido, Marcus Luiz de Oliveira; Paiva, Marco Antônio Ribeiro; Teodoro, Janaína Aparecida Reis; Augusti, Rodinei; Nascentes, Clésia Cristina

    2013-09-27

    A simple and efficient method was developed for the determination of cocaine in post-mortem samples of human liver via solid-liquid extraction with low temperature partitioning (SLE-LTP) and analysis by gas chromatography coupled to mass spectrometry (GC-MS). The extraction procedure was optimized by evaluating the influence of the following variables: pH of the extract, volume and composition of the extractor solvent, addition of a sorbent material (PSA: primary-secondary amine) and NaCl to clean up and increase the ionic strength of the extract. A bovine liver sample that was free of cocaine was used as a blank for the optimization of the SLE-LTP extraction procedure. The highest recovery was obtained when crushed bovine liver (2g) was treated with 2mL of ultrapure water plus 8mL of acetonitrile at physiological pH (7.4). The results also indicated no need for using PSA and NaCl. The complete analytical procedure was validated for the following figures of merit: selectivity, lower limit of quantification (LLOQ), calibration curve, recovery, precision and accuracy (for within-run and between-run experiments), matrix effect, dilution integrity and stability. The within-run and between-run precision (at four levels) varied from 2.1% to 9.4% and from 4.0% to 17.0%, respectively. A maximum deviation of 11.62% for the within-run and between-run accuracies in relation to the nominal concentrations was observed. Moreover, the LLOQ value for cocaine was 50.0ngg(-1) whereas no significant effects were noticed in the assays of dilution integrity and stability. To assess its overall performance, the optimized method was applied to the analysis of eight human liver samples collected from individuals who died due to the abusive consumption of cocaine. Due to the existence of a significant matrix effect, a blank human liver was used to construct a matrix-matched analytical curve. The concentrations of cocaine found in these samples ranged from 333.5 to 5969ngg(-1). Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Investigation of residual stresses in shape memory alloy (SMA) composites

    NASA Astrophysics Data System (ADS)

    Berman, Justin Bradley

    Shape memory alloy (SMA) composites are a class of smart materials in which SMA actuators are embedded in a host matrix. The shape memory effect allows for stress induced phase transformations and large recoverable strains that make SMA composites promising candidates for structural shape/vibration control, impact absorption, aircraft deicing or in-flight airfoil shape control systems. However, the difference in thermal expansion between the SMA and the host material leads to residual stresses during processing. In addition, the SMA transformation from martensite to austenite, or the reverse, also generate stresses. These stresses acting in combination can lead to SMA/polymer interfacial debonding or microcracking of the host matrix. The present work was undertaken to study the behavior of nitinol shape memory alloys embedded in epoxy and glass/epoxy matrices and to investigate the development of residual stresses during their manufacture and actuation. A three-phase concentric cylinder micromechanics model and an SMA composite thermoelastic beam theory were developed to analyze the micromechanical and structural-level thermal and transformational stresses for nitinol composites induced by nitinol wires embedded in a host matrix. A series of warpage experiments were conducted on nitinol composite beams during heating cycles to provide experimental validation of model predictions and to assess their thermoelastic structural behavior under non-mechanical loading. Micromechanical model results indicate that excessive residual hoop stresses in nitino/graphite/epoxy composites leads to radial cracking around the embedded nitinol wires. Based on modeling results, the most important factor in reducing residual stresses (and thereby preventing radial cracking) is increasing the level of recovery strain for the nitinol wire. The SMA composite beam model agrees well with experimental data captured for the nitinol/epoxy beam series. Warpage experiments on nitinol/glass/epoxy beams showed a large increase in the effective austenitic start temperature (As) of 9.3°C. The elevation of the effective As together with other observations of warpage development indicates that plastic flow may have occurred in nitinol wires when embedded in glass/epoxy. These observations reinforce the need to train nitinol wires at modest recovery levels when embedding in relatively stiff materials.

  17. Experiment K-310: The effect of spaceflight on osteogenesis and dentinogenesis in the mandibles of rats

    NASA Technical Reports Server (NTRS)

    Simmons, D. J.; Russell, J. E.; Winter, F.; Rosenberg, G. D.; Walker, W. V.

    1981-01-01

    Normal rates of dentinogenesis and osteogenesis in the body of the mandible were observed. The total calcium, inorganic phosphorus and hydroxyproline levels in the jaws and incisors of the flight rats were normal. Gravity density fractionation studies suggested, however, that spaceflight caused a delay in the normal maturation of bone mineral and matrix; normal values were reestablished by 6 days postflight. The teeth were spared. The circadian and ultradian patterns of dentin calcification were normal during spaceflight and recovery periods, but the enamel rhythms displayed a greater amplitude of sulfur concentrations and this abnormal calcium to sulfur ratios only during exposure to zero gravity. The rat mandible and teeth do not suffer the deficits of bone formation common to weight bearing parts of the skeleton during spaceflight. The only derangements detected were in the quality of the matrix and mineral moieties.

  18. Enhancing performance and surface antifouling properties of polysulfone ultrafiltration membranes with salicylate-alumoxane nanoparticles

    NASA Astrophysics Data System (ADS)

    Mokhtari, Samaneh; Rahimpour, Ahmad; Shamsabadi, Ahmad Arabi; Habibzadeh, Setareh; Soroush, Masoud

    2017-01-01

    To improve the hydrophilicity and antifouling properties of polysulfone (PS) ultrafiltration membranes, we studied the use of salicylate-alumoxane (SA) nanoparticles as a novel hydrophilic additive. The effects of SA nanoparticles on the membrane characteristics and performance were investigated in terms of membrane structure, permeation flux, solute rejection, hydrophilicity, and antifouling ability. The new mixed-matrix membranes (MMMs) possess asymmetric structures. They have smaller finger-like pores and smoother surfaces than the neat PS membranes. The embedment of SA nanoparticles in the polymer matrix and the improvement of surface hydrophilicity were investigated. Ultrafiltration experiments indicated that the pure-water flux of the new MMMs initially increases with SA nanoparticles loading followed by a decrease at high loadings. Higher BSA solution flux was achieved for the MMMs compared to the neat PS membranes. Membranes with 1 wt.% SA nanoparticles exhibit the highest flux recovery ratio of 87% and the lowest irreversible fouling of 13%.

  19. Effect of Numerical Error on Gravity Field Estimation for GRACE and Future Gravity Missions

    NASA Astrophysics Data System (ADS)

    McCullough, Christopher; Bettadpur, Srinivas

    2015-04-01

    In recent decades, gravity field determination from low Earth orbiting satellites, such as the Gravity Recovery and Climate Experiment (GRACE), has become increasingly more effective due to the incorporation of high accuracy measurement devices. Since instrumentation quality will only increase in the near future and the gravity field determination process is computationally and numerically intensive, numerical error from the use of double precision arithmetic will eventually become a prominent error source. While using double-extended or quadruple precision arithmetic will reduce these errors, the numerical limitations of current orbit determination algorithms and processes must be accurately identified and quantified in order to adequately inform the science data processing techniques of future gravity missions. The most obvious numerical limitation in the orbit determination process is evident in the comparison of measured observables with computed values, derived from mathematical models relating the satellites' numerically integrated state to the observable. Significant error in the computed trajectory will corrupt this comparison and induce error in the least squares solution of the gravitational field. In addition, errors in the numerically computed trajectory propagate into the evaluation of the mathematical measurement model's partial derivatives. These errors amalgamate in turn with numerical error from the computation of the state transition matrix, computed using the variational equations of motion, in the least squares mapping matrix. Finally, the solution of the linearized least squares system, computed using a QR factorization, is also susceptible to numerical error. Certain interesting combinations of each of these numerical errors are examined in the framework of GRACE gravity field determination to analyze and quantify their effects on gravity field recovery.

  20. Trehalose significantly enhances the recovery of serum and serum exosomal miRNA from a paper-based matrix.

    PubMed

    Neo, Shu Hui; Chung, Ka Yan; Quek, Jia Min; Too, Heng-Phon

    2017-11-30

    The preservation of nucleic acids from clinical samples is critical to facilitate accurate molecular diagnosis. The use of a paper matrix, Flinders Technology Associates (FTA) Elute cards, to archive DNA and viral RNA is well-documented. However, the feasibility of FTA Elute cards for archiving serum and serum exosomal microRNAs (miRNAs) remains unclear. Here, we performed a comprehensive evaluation of FTA Elute cards for miRNA storage and recovery in different pre-analytical conditions. The recovery of serum miRNA dry-spotted on FTA Elute cards by direct elution with water at high temperature was poor. However, serum miRNAs dry-spotted on the cards were isolated with about 40% yield when using QIAzol lysis reagent and recovery was improved remarkably (>80%) upon extraction from cards pre-treated with trehalose. miRNAs stored on the cards remained stable at room temperature and can be kept for prolonged periods. Furthermore, miRNAs could be similarly recovered from serum exosomes dry-spotted on the cards. Importantly, when using sera from gastric cancer (GC) patients, the miRNAs were efficiently recovered from trehalose pre-treated cards without affecting their representation. Collectively, we have demonstrated the potential of FTA Elute cards to archive serum and serum exosomal miRNAs, making it useful for biomarker discovery and diagnostics.

  1. Repair of traumatic skeletal muscle injury with bone-marrow-derived mesenchymal stem cells seeded on extracellular matrix.

    PubMed

    Merritt, Edward K; Cannon, Megan V; Hammers, David W; Le, Long N; Gokhale, Rohit; Sarathy, Apurva; Song, Tae J; Tierney, Matthew T; Suggs, Laura J; Walters, Thomas J; Farrar, Roger P

    2010-09-01

    Skeletal muscle injury resulting in tissue loss poses unique challenges for surgical repair. Despite the regenerative potential of skeletal muscle, if a significant amount of tissue is lost, skeletal myofibers will not grow to fill the injured area completely. Prior work in our lab has shown the potential to fill the void with an extracellular matrix (ECM) scaffold, resulting in restoration of morphology, but not functional recovery. To improve the functional outcome of the injured muscle, a muscle-derived ECM was implanted into a 1 x 1 cm(2), full-thickness defect in the lateral gastrocnemius (LGAS) of Lewis rats. Seven days later, bone-marrow-derived mesenchymal stem cells (MSCs) were injected directly into the implanted ECM. Partial functional recovery occurred over the course of 42 days when the LGAS was repaired with an MSC-seeded ECM producing 85.4 +/- 3.6% of the contralateral LGAS. This was significantly higher than earlier recovery time points (p < 0.05). The specific tension returned to 94 +/- 9% of the contralateral limb. The implanted MSC-seeded ECM had more blood vessels and regenerating skeletal myofibers than the ECM without cells (p < 0.05). The data suggest that the repair of a skeletal muscle defect injury by the implantation of a muscle-derived ECM seeded with MSCs can improve functional recovery after 42 days.

  2. Spectroscopic characterization of bone tissue of experimental animals after glucocorticoid treatment and recovery period

    NASA Astrophysics Data System (ADS)

    Mitić, Žarko J.; Najman, Stevo J.; Cakić, Milorad D.; Ajduković, Zorica R.; Ignjatović, Nenad L.; Nikolić, Ružica S.; Nikolić, Goran M.; Stojanović, Sanja T.; Vukelić, Marija Đ.; Trajanović, Miroslav D.

    2014-09-01

    The influence of glucocorticoids on the composition and mineral/organic content of the mandible in tested animals after recovery and healing phase was investigated in this work. The results of FTIR analysis demonstrated that bone tissue composition was changed after glucocorticoid treatment. The increase of calcium, magnesium, phosphorus content and mineral part of bones was statistically significant in recovery phase and in treatment phase that included calcitonin and thymus extract. Some changes also happened in the organic part of the matrix, as indicated by intensity changes for already present IR bands and the appearance of new IR bands in the region 3500-1300 cm-1.

  3. A quasi steady state method for solving transient Darcy flow in complex 3D fractured networks accounting for matrix to fracture flow

    NASA Astrophysics Data System (ADS)

    Nœtinger, B.

    2015-02-01

    Modeling natural Discrete Fracture Networks (DFN) receives more and more attention in applied geosciences, from oil and gas industry, to geothermal recovery and aquifer management. The fractures may be either natural, or artificial in case of well stimulation. Accounting for the flow inside the fracture network, and accounting for the transfers between the matrix and the fractures, with the same level of accuracy is an important issue for calibrating the well architecture and for setting up optimal resources recovery strategies. Recently, we proposed an original method allowing to model transient pressure diffusion in the fracture network only [1]. The matrix was assumed to be impervious. A systematic approximation scheme was built, allowing to model the initial DFN by a set of N unknowns located at each identified intersection between fractures. The higher N, the higher the accuracy of the model. The main assumption was using a quasi steady state hypothesis, that states that the characteristic diffusion time over one single fracture is negligible compared with the characteristic time of the macroscopic problem, e.g. change of boundary conditions. In that context, the lowest order approximation N = 1 has the form of solving a transient problem in a resistor/capacitor network, a so-called pipe network. Its topology is the same as the network of geometrical intersections between fractures. In this paper, we generalize this approach in order to account for fluxes from matrix to fractures. The quasi steady state hypothesis at the fracture level is still kept. Then, we show that in the case of well separated time scales between matrix and fractures, the preceding model needs only to be slightly modified in order to incorporate these fluxes. The additional knowledge of the so-called matrix to fracture transfer function allows to modify the mass matrix that becomes a time convolution operator. This is reminiscent of existing space averaged transient dual porosity models.

  4. High efficient optical remote sensing images acquisition for nano-satellite: reconstruction algorithms

    NASA Astrophysics Data System (ADS)

    Liu, Yang; Li, Feng; Xin, Lei; Fu, Jie; Huang, Puming

    2017-10-01

    Large amount of data is one of the most obvious features in satellite based remote sensing systems, which is also a burden for data processing and transmission. The theory of compressive sensing(CS) has been proposed for almost a decade, and massive experiments show that CS has favorable performance in data compression and recovery, so we apply CS theory to remote sensing images acquisition. In CS, the construction of classical sensing matrix for all sparse signals has to satisfy the Restricted Isometry Property (RIP) strictly, which limits applying CS in practical in image compression. While for remote sensing images, we know some inherent characteristics such as non-negative, smoothness and etc.. Therefore, the goal of this paper is to present a novel measurement matrix that breaks RIP. The new sensing matrix consists of two parts: the standard Nyquist sampling matrix for thumbnails and the conventional CS sampling matrix. Since most of sun-synchronous based satellites fly around the earth 90 minutes and the revisit cycle is also short, lots of previously captured remote sensing images of the same place are available in advance. This drives us to reconstruct remote sensing images through a deep learning approach with those measurements from the new framework. Therefore, we propose a novel deep convolutional neural network (CNN) architecture which takes in undersampsing measurements as input and outputs an intermediate reconstruction image. It is well known that the training procedure to the network costs long time, luckily, the training step can be done only once, which makes the approach attractive for a host of sparse recovery problems.

  5. Cavernous nerve repair with allogenic adipose matrix and autologous adipose-derived stem cells.

    PubMed

    Lin, Guiting; Albersen, Maarten; Harraz, Ahmed M; Fandel, Thomas M; Garcia, Maurice; McGrath, Mary H; Konety, Badrinath R; Lue, Tom F; Lin, Ching-Shwun

    2011-06-01

    To investigate whether adipose-derived matrix seeded with adipose-derived stem cells (ADSC) can facilitate the repair of injured cavernous nerves (CNs). Human and rat adipose tissues were decellularized and fabricated into various forms, including adipose tissue-derived acellular matrix thread (ADMT). ADMT seeded with ADSC were transplanted into subcutaneous space and examined for signs of inflammation. ADSC-seeded ADMTs were then used to repair CN injury in rats, followed by assessment of histology and erectile function. Adipose tissue can be fabricated into acellular matrices of various shapes and sizes, including threads and sheets. Seeding of ADMT occurred rapidly: within 24 hours, 55% of the surface was covered with ADSC and within 1 week, 90% was covered. Transplantation of the seeded ADMT into the subcutaneous space of an allogenic host showed no signs of inflammatory reaction. At 3 months after grafting into CN injury rats, approximately twice as many cells were found on seeded ADMT as on unseeded ADMT. The seeded ADMT also had various degrees of S100 and neuronal nitric oxide synthase expression, suggesting CN axonal ingrowth. Rats grafted with seeded ADMT overall had the best erectile function recovery when compared with those grafted with unseeded ADMT and those ungrafted. However, as a result of large variations, the differences did not reach statistic significance (P = .07). Grafting of ADSC-seeded matrix resulted in a substantial recovery of erectile function and improvement of histology. However, further refinement of the matrix architecture is needed to improve the success rate. Copyright © 2011 Elsevier Inc. All rights reserved.

  6. Tendon Reattachment to Bone in an Ovine Tendon Defect Model of Retraction Using Allogenic and Xenogenic Demineralised Bone Matrix Incorporated with Mesenchymal Stem Cells.

    PubMed

    Thangarajah, Tanujan; Shahbazi, Shirin; Pendegrass, Catherine J; Lambert, Simon; Alexander, Susan; Blunn, Gordon W

    2016-01-01

    Tendon-bone healing following rotator cuff repairs is mainly impaired by poor tissue quality. Demineralised bone matrix promotes healing of the tendon-bone interface but its role in the treatment of tendon tears with retraction has not been investigated. We hypothesized that cortical demineralised bone matrix used with minimally manipulated mesenchymal stem cells will result in improved function and restoration of the tendon-bone interface with no difference between xenogenic and allogenic scaffolds. In an ovine model, the patellar tendon was detached from the tibial tuberosity and a complete distal tendon transverse defect measuring 1 cm was created. Suture anchors were used to reattach the tendon and xenogenic demineralised bone matrix + minimally manipulated mesenchymal stem cells (n = 5), or allogenic demineralised bone matrix + minimally manipulated mesenchymal stem cells (n = 5) were used to bridge the defect. Graft incorporation into the tendon and its effect on regeneration of the enthesis was assessed using histomorphometry. Force plate analysis was used to assess functional recovery. Compared to the xenograft, the allograft was associated with significantly higher functional weight bearing at 6 (P = 0.047), 9 (P = 0.028), and 12 weeks (P = 0.009). In the allogenic group this was accompanied by greater remodeling of the demineralised bone matrix into tendon-like tissue in the region of the defect (p = 0.015), and a more direct type of enthesis characterized by significantly more fibrocartilage (p = 0.039). No failures of tendon-bone healing were noted in either group. Demineralised bone matrix used with minimally manipulated mesenchymal stem cells promotes healing of the tendon-bone interface in an ovine model of acute tendon retraction, with superior mechanical and histological results associated with use of an allograft.

  7. CTEPP-OH DATA QA/QC RESULTS

    EPA Science Inventory

    This data set contains the method performance results for CTEPP-OH. This includes field blanks, method blanks, duplicate samples, analytical duplicates, matrix spikes, and surrogate recovery standards.

    The Children’s Total Exposure to Persistent Pesticides and Other Persisten...

  8. Determination of sulfonamides in livers using matrix solid-phase dispersion extraction high-performance liquid chromatography.

    PubMed

    Zhang, Yupu; Xu, Xu; Qi, Xiao; Gao, Wenquan; Sun, Shuo; Li, Xiaotian; Jiang, Chengfei; Yu, Aimin; Zhang, Hanqi; Yu, Yong

    2012-01-01

    The matrix solid-phase dispersion (MSPD) was applied for extracting seven sulfonamides (SAs) in liver samples. The separation and determination were carried out by high-performance liquid chromatography. The analytes were derivated with fluorescamine and detected with fluorescence detector. The types of dispersion adsorbents for MSPD were examined and the highest recovery was obtained when the diatomaceous earth was used as the dispersion adsorbent and the mass ratio of dispersion adsorbent to sample was 3:1. The acetone was used as the elution solvent. Under the optimal conditions, the linear range for determining the SAs in liver samples was 5.0-1000.0 ng/g. The porcine, chicken and cattle liver samples were analyzed and the average recoveries of seven SAs were higher than 84.6%. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Planning and Analysis of Fractured Rock Injection Tests in the Cerro Brillador Underground Laboratory, Northern Chile

    NASA Astrophysics Data System (ADS)

    Fairley, J. P., Jr.; Oyarzún L, R.; Villegas, G.

    2015-12-01

    Early theories of fluid migration in unsaturated fractured rock hypothesized that matrix suction would dominate flow up to the point of matrix saturation. However, experiments in underground laboratories such as the ESF (Yucca Mountain, NV) have demonstrated that liquid water can migrate significant distances through fractures in an unsaturated porous medium, suggesting limited interaction between fractures and unsaturated matrix blocks and potentially rapid transmission of recharge to the sat- urated zone. Determining the conditions under which this rapid recharge may take place is an important factor in understanding deep percolation processes in arid areas with thick unsaturated zones. As part of an on-going, Fondecyt-funded project (award 11150587) to study mountain block hydrological processes in arid regions, we are plan- ning a series of in-situ fracture flow injection tests in the Cerro Brillador/Mina Escuela, an underground laboratory and teaching facility belonging to the Universidad la Serena, Chile. Planning for the tests is based on an analytical model and curve-matching method, originally developed to evaluate data from injection tests at Yucca Mountain (Fairley, J.P., 2010, WRR 46:W08542), that uses a known rate of liquid injection to a fracture (for example, from a packed-off section of borehole) and the observed rate of seepage discharging from the fracture to estimate effective fracture aperture, matrix sorptivity, fracture/matrix flow partitioning, and the wetted fracture/matrix interac- tion area between the injection and recovery points. We briefly review the analytical approach and its application to test planning and analysis, and describe the proposed tests and their goals.

  10. High-performance thin-layer chromatography analysis of steviol glycosides in Stevia formulations and sugar-free food products, and benchmarking with (ultra) high-performance liquid chromatography.

    PubMed

    Morlock, Gertrud E; Meyer, Stephanie; Zimmermann, Benno F; Roussel, Jean-Marc

    2014-07-11

    A high-performance TLC (HPTLC) method was newly developed and validated for analysis of 7 steviol glycosides in 6 different types of food and Stevia formulations. After a minimized one-step sample preparation, 21 samples were developed in parallel, allowing an effective food screening. Depending on the sample application volume, the method was suited to analyze food sample concentrations in the mg/kg range. LOQs of stevioside in natural yoghurt matrix spiked at 0.02, 0.13 and 0.2% were determined by the calibration curve method to be 12ng/band (peak height). ANOVA was successfully passed to prove data homogeneity in the working range (30-600ng/band). The accuracy (recovery tolerance limit, 92-120%), repeatability (3.1-5.4%) and intermediate precision (4.0-8.4%) were determined for stevioside in milk-based matrix including sample preparation and recovery rates at 3 different concentration levels. For the first time, the recording of HPTLC-ESI-MS spectra via the TLC-MS Interface was demonstrated for rebaudioside A. HPTLC contents for rebaudioside A were compared with results of two (U)HPLC methods. The running costs and analysis time of the three different methods were discussed in detail with regard to screening of food products. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Improving washing strategies of human mesenchymal stem cells using negative mode expanded bed chromatography.

    PubMed

    Cunha, Bárbara; Silva, Ricardo J S; Aguiar, Tiago; Serra, Margarida; Daicic, John; Maloisel, Jean-Luc; Clachan, John; Åkerblom, Anna; Carrondo, Manuel J T; Peixoto, Cristina; Alves, Paula M

    2016-01-15

    The use of human mesenchymal stem cells (hMSC) in clinical applications has been increasing over the last decade. However, to be applied in a clinical setting hMSC need to comply with specific requirements in terms of identity, potency and purity. This study reports the improvement of established tangential flow filtration (TFF)-based washing strategies, further increasing hMSC purity, using negative mode expanded bed adsorption (EBA) chromatography with a new multimodal prototype matrix based on core-shell bead technology. The matrix was characterized and a stable, expanded bed could be obtained using standard equipment adapted from what is used for conventional packed bed chromatography processes. The effect of different expansion rates on cell recovery yield and protein removal capacity was assessed. The best trade-off between cell recovery (89%) and protein clearance (67%) was achieved using an intermediate expansion bed rate (1.4). Furthermore, we also showed that EBA chromatography can be efficiently integrated on the already established process for the downstream processing (DSP) of hMSC, where it improved the washing efficiency more than 10-fold, recovering approximately 70% of cells after global processing. This strategy showed not to impact cell viability (>95%), neither hMSC's characteristics in terms of morphology, immunophenotype, proliferation, adhesion capacity and multipotent differentiation potential. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Antifouling booster biocide extraction from marine sediments: a fast and simple method based on vortex-assisted matrix solid-phase extraction.

    PubMed

    Caldas, Sergiane Souza; Soares, Bruno Meira; Abreu, Fiamma; Castro, Ítalo Braga; Fillmann, Gilberto; Primel, Ednei Gilberto

    2018-03-01

    This paper reports the development of an analytical method employing vortex-assisted matrix solid-phase dispersion (MSPD) for the extraction of diuron, Irgarol 1051, TCMTB (2-thiocyanomethylthiobenzothiazole), DCOIT (4,5-dichloro-2-n-octyl-3-(2H)-isothiazolin-3-one), and dichlofluanid from sediment samples. Separation and determination were performed by liquid chromatography tandem-mass spectrometry. Important MSPD parameters, such as sample mass, mass of C18, and type and volume of extraction solvent, were investigated by response surface methodology. Quantitative recoveries were obtained with 2.0 g of sediment sample, 0.25 g of C18 as the solid support, and 10 mL of methanol as the extraction solvent. The MSPD method was suitable for the extraction and determination of antifouling biocides in sediment samples, with recoveries between 61 and 103% and a relative standard deviation lower than 19%. Limits of quantification between 0.5 and 5 ng g -1 were obtained. Vortex-assisted MPSD was shown to be fast and easy to use, with the advantages of low cost and reduced solvent consumption compared to the commonly employed techniques for the extraction of booster biocides from sediment samples. Finally, the developed method was applied to real samples. Results revealed that the developed extraction method is effective and simple, thus allowing the determination of biocides in sediment samples.

  13. Protein structure estimation from NMR data by matrix completion.

    PubMed

    Li, Zhicheng; Li, Yang; Lei, Qiang; Zhao, Qing

    2017-09-01

    Knowledge of protein structures is very important to understand their corresponding physical and chemical properties. Nuclear Magnetic Resonance (NMR) spectroscopy is one of the main methods to measure protein structure. In this paper, we propose a two-stage approach to calculate the structure of a protein from a highly incomplete distance matrix, where most data are obtained from NMR. We first randomly "guess" a small part of unobservable distances by utilizing the triangle inequality, which is crucial for the second stage. Then we use matrix completion to calculate the protein structure from the obtained incomplete distance matrix. We apply the accelerated proximal gradient algorithm to solve the corresponding optimization problem. Furthermore, the recovery error of our method is analyzed, and its efficiency is demonstrated by several practical examples.

  14. Sparse electrocardiogram signals recovery based on solving a row echelon-like form of system.

    PubMed

    Cai, Pingmei; Wang, Guinan; Yu, Shiwei; Zhang, Hongjuan; Ding, Shuxue; Wu, Zikai

    2016-02-01

    The study of biology and medicine in a noise environment is an evolving direction in biological data analysis. Among these studies, analysis of electrocardiogram (ECG) signals in a noise environment is a challenging direction in personalized medicine. Due to its periodic characteristic, ECG signal can be roughly regarded as sparse biomedical signals. This study proposes a two-stage recovery algorithm for sparse biomedical signals in time domain. In the first stage, the concentration subspaces are found in advance. Then by exploiting these subspaces, the mixing matrix is estimated accurately. In the second stage, based on the number of active sources at each time point, the time points are divided into different layers. Next, by constructing some transformation matrices, these time points form a row echelon-like system. After that, the sources at each layer can be solved out explicitly by corresponding matrix operations. It is noting that all these operations are conducted under a weak sparse condition that the number of active sources is less than the number of observations. Experimental results show that the proposed method has a better performance for sparse ECG signal recovery problem.

  15. Creep-induced residual stress strengthening in a Nicalon-fiber-reinforced BMAS-glass-ceramic-matrix composite

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Widjaja, S.; Jakus, K.; Ritter, J.E.

    The feasibility of inducing a compressive residual stress in the matrix of a Nicalon-fiber-reinforced BMAS-glass-ceramic-matrix composite through a creep-load transfer treatment was studied. Specimens were crept at 1100 C under constant tensile load to cause load transfer from the matrix to the fibers, then cooled under load. Upon removal of the load at room temperature, the matrix was put into compression by the elastic recovery of the fibers. This compressive residual stress in the matrix increased the room-temperature proportional limit stress of the composite. The increase in the proportional limit stress was found to be dependent upon the applied creepmore » stress, with an increase in creep stress resulting in an increase in the proportional limit stress. Acoustic emission results showed that the onset of significant matrix cracking correlated closely to the proportional limit stress. Changes in the state of residual stress in the matrix were supported by X-ray diffraction results. Fracture surfaces of all specimens exhibited fiber pullout behavior, indicating that the creep-load transfer process did not embrittle the fiber/matrix interface.« less

  16. Adsorbing/dissolving Lyoprotectant Matrix Technology for Non-cryogenic Storage of Archival Human Sera

    NASA Astrophysics Data System (ADS)

    Solivio, Morwena J.; Less, Rebekah; Rynes, Mathew L.; Kramer, Marcus; Aksan, Alptekin

    2016-04-01

    Despite abundant research conducted on cancer biomarker discovery and validation, to date, less than two-dozen biomarkers have been approved by the FDA for clinical use. One main reason is attributed to inadvertent use of low quality biospecimens in biomarker research. Most proteinaceous biomarkers are extremely susceptible to pre-analytical factors such as collection, processing, and storage. For example, cryogenic storage imposes very harsh chemical, physical, and mechanical stresses on biospecimens, significantly compromising sample quality. In this communication, we report the development of an electrospun lyoprotectant matrix and isothermal vitrification methodology for non-cryogenic stabilization and storage of liquid biospecimens. The lyoprotectant matrix was mainly composed of trehalose and dextran (and various low concentration excipients targeting different mechanisms of damage), and it was engineered to minimize heterogeneity during vitrification. The technology was validated using five biomarkers; LDH, CRP, PSA, MMP-7, and C3a. Complete recovery of LDH, CRP, and PSA levels was achieved post-rehydration while more than 90% recovery was accomplished for MMP-7 and C3a, showing promise for isothermal vitrification as a safe, efficient, and low-cost alternative to cryogenic storage.

  17. Lactation-Induced Changes in the Volume of Osteocyte Lacunar-Canalicular Space Alter Mechanical Properties in Cortical Bone Tissue.

    PubMed

    Kaya, Serra; Basta-Pljakic, Jelena; Seref-Ferlengez, Zeynep; Majeska, Robert J; Cardoso, Luis; Bromage, Timothy G; Zhang, Qihong; Flach, Carol R; Mendelsohn, Richard; Yakar, Shoshana; Fritton, Susannah P; Schaffler, Mitchell B

    2017-04-01

    Osteocytes can remove and remodel small amounts of their surrounding bone matrix through osteocytic osteolysis, which results in increased volume occupied by lacunar and canalicular space (LCS). It is well established that cortical bone stiffness and strength are strongly and inversely correlated with vascular porosity, but whether changes in LCS volume caused by osteocytic osteolysis are large enough to affect bone mechanical properties is not known. In the current studies we tested the hypotheses that (1) lactation and postlactation recovery in mice alter the elastic modulus of bone tissue, and (2) such local changes in mechanical properties are related predominantly to alterations in lacunar and canalicular volume rather than bone matrix composition. Mechanical testing was performed using microindentation to measure modulus in regions containing solely osteocytes and no vascular porosity. Lactation caused a significant (∼13%) reduction in bone tissue-level elastic modulus (p < 0.001). After 1 week postweaning (recovery), bone modulus levels returned to control levels and did not change further after 4 weeks of recovery. LCS porosity tracked inversely with changes in cortical bone modulus. Lacunar and canalicular void space increased 7% and 15% with lactation, respectively (p < 0.05), then returned to control levels at 1 week after weaning. Neither bone mineralization (assessed by high-resolution backscattered scanning electron microscopy) nor mineral/matrix ratio or crystallinity (assessed by Raman microspectroscopy) changed with lactation. Thus, changes in bone mechanical properties induced by lactation and recovery appear to depend predominantly on changes in osteocyte LCS dimensions. Moreover, this study demonstrates that tissue-level cortical bone mechanical properties are rapidly and reversibly modulated by osteocytes in response to physiological challenge. These data point to a hitherto unappreciated role for osteocytes in modulating and maintaining local bone mechanical properties. © 2016 American Society for Bone and Mineral Research. © 2016 American Society for Bone and Mineral Research.

  18. The Augmented Lagrange Multipliers Method for Matrix Completion from Corrupted Samplings with Application to Mixed Gaussian-Impulse Noise Removal

    PubMed Central

    Meng, Fan; Yang, Xiaomei; Zhou, Chenghu

    2014-01-01

    This paper studies the problem of the restoration of images corrupted by mixed Gaussian-impulse noise. In recent years, low-rank matrix reconstruction has become a research hotspot in many scientific and engineering domains such as machine learning, image processing, computer vision and bioinformatics, which mainly involves the problem of matrix completion and robust principal component analysis, namely recovering a low-rank matrix from an incomplete but accurate sampling subset of its entries and from an observed data matrix with an unknown fraction of its entries being arbitrarily corrupted, respectively. Inspired by these ideas, we consider the problem of recovering a low-rank matrix from an incomplete sampling subset of its entries with an unknown fraction of the samplings contaminated by arbitrary errors, which is defined as the problem of matrix completion from corrupted samplings and modeled as a convex optimization problem that minimizes a combination of the nuclear norm and the -norm in this paper. Meanwhile, we put forward a novel and effective algorithm called augmented Lagrange multipliers to exactly solve the problem. For mixed Gaussian-impulse noise removal, we regard it as the problem of matrix completion from corrupted samplings, and restore the noisy image following an impulse-detecting procedure. Compared with some existing methods for mixed noise removal, the recovery quality performance of our method is dominant if images possess low-rank features such as geometrically regular textures and similar structured contents; especially when the density of impulse noise is relatively high and the variance of Gaussian noise is small, our method can outperform the traditional methods significantly not only in the simultaneous removal of Gaussian noise and impulse noise, and the restoration ability for a low-rank image matrix, but also in the preservation of textures and details in the image. PMID:25248103

  19. Cyclic Creep and Recovery Behavior of Nextel(Trademark) 720/Alumina Ceramic Matrix Composite at 1200deg C in Air and in Steam Environments

    DTIC Science & Technology

    2007-09-01

    steam. The creep and recovery periods ranged from 3 min to 30 h. The laboratory air tests significantly exceeded the life of the monotonic creep ...orders of magnitude improvement in the creep life and rate. The presence of steam greatly reduced the performance of the material. The results in...steam. Mehrman also reported that prior fatigue subsequently improved in air but creep performance but in steam creep performance remained poor

  20. Immobilization and long-term recovery results in large changes in bone structure and strength but no corresponding alterations of osteocyte lacunar properties.

    PubMed

    Bach-Gansmo, Fiona Linnea; Wittig, Nina Kølln; Brüel, Annemarie; Thomsen, Jesper Skovhus; Birkedal, Henrik

    2016-10-01

    The ability of osteocytes to demineralize the perilacunar matrix, osteocytic osteolysis, and thereby participate directly in bone metabolism, is an aspect of osteocyte biology that has received increasing attention during the last couple of years. The aim of the present work was to investigate whether osteocyte lacunar properties change during immobilization and subsequent recovery. A rat cortical bone model with negligible Haversian remodeling effects was used, with temporary immobilization of one hindlimb induced by botulinum toxin. Several complementary techniques covering multiple length scales enabled correlation of osteocyte lacunar properties to changes observed on the organ and tissue level of femoral bone. Bone structural parameters measured by μCT and mechanical properties were compared to sub-micrometer resolution SR μCT data mapping an unprecedented number (1.85 million) of osteocyte lacunae. Immobilization induced a significant reduction in aBMD, bone volume, tissue volume, and load to fracture, as well as the muscle mass of rectus femoris. During the subsequent recovery period, the bone structural and mechanical properties were only partly regained in spite of a long-term (28weeks) study period. No significant changes in osteocyte lacunar volume, density, oblateness, stretch, or orientation were detected upon immobilization or subsequent recovery. In conclusion, the bone architecture and not osteocyte lacunar properties or bone material characteristics dominate the immobilization response as well as the subsequent recovery. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Effect of a freeze-dried CMC/PLGA microsphere matrix of rhBMP-2 on bone healing.

    PubMed

    Schrier, J A; Fink, B F; Rodgers, J B; Vasconez, H C; DeLuca, P P

    2001-10-07

    The hypothesis of this research was that implants of poly(lactide-co-glycolide) (PLGA) microspheres loaded with bone morphogenetic protein-2 (rhBMP-2) and distributed in a freeze-dried carboxymethylcellulose (CMC) matrix would produce more new bone than would matrix implants of non-protein-loaded microspheres or matrix implants of only CMC. To test this hypothesis it was necessary to fashion microsphere-loaded CMC implants that were simple to insert, fit precisely into a defect, and would not elicit swelling. Microspheres were produced via a water-in-oil-in-water double-emulsion system and were loaded with rhBMP-2 by soaking them in a buffered solution of the protein at a concentration of 5.4 mg protein per gram of PLGA. Following recovery of the loaded microspheres by lyophilization, matrices for implantation were prepared by lyophilizing a suspension of the microspheres in 2% CMC in flat-bottom tissue culture plates. Similar matrices were made with 2% CMC and with 2% CMC containing blank microspheres. A full-thickness calvarial defect model in New Zealand white rabbits was used to assess bone growth. Implants fit the defect well, allowing for direct application. Six weeks postsurgery, defects were collected and processed for undecalcified histology. In vitro, 60% of the loaded rhBMP-2 released from devices or microspheres in 5 to 7 days, with the unembedded microspheres releasing faster than those embedded in CMC. In vivo, the rhBMP-2 microspheres greatly enhanced bone healing, whereas nonloaded PLGA microspheres in the CMC implants had little effect. The results showed that a lyophilized device of rhBMP-2/PLGA microspheres in CMC was an effective implantable protein-delivery system for use in bone repair.

  2. Measurement Matrix Design for Phase Retrieval Based on Mutual Information

    NASA Astrophysics Data System (ADS)

    Shlezinger, Nir; Dabora, Ron; Eldar, Yonina C.

    2018-01-01

    In phase retrieval problems, a signal of interest (SOI) is reconstructed based on the magnitude of a linear transformation of the SOI observed with additive noise. The linear transform is typically referred to as a measurement matrix. Many works on phase retrieval assume that the measurement matrix is a random Gaussian matrix, which, in the noiseless scenario with sufficiently many measurements, guarantees invertability of the transformation between the SOI and the observations, up to an inherent phase ambiguity. However, in many practical applications, the measurement matrix corresponds to an underlying physical setup, and is therefore deterministic, possibly with structural constraints. In this work we study the design of deterministic measurement matrices, based on maximizing the mutual information between the SOI and the observations. We characterize necessary conditions for the optimality of a measurement matrix, and analytically obtain the optimal matrix in the low signal-to-noise ratio regime. Practical methods for designing general measurement matrices and masked Fourier measurements are proposed. Simulation tests demonstrate the performance gain achieved by the proposed techniques compared to random Gaussian measurements for various phase recovery algorithms.

  3. Inclusion of 1-naphthylacetic acid and 2-(1-naphthyl)acetamide into three typical multiresidue methods for LC/MS/MS analysis of tomatoes and zucchini.

    PubMed

    Lozano, Ana; Pérez-Parada, Andrés; Heinzen, Horacio; Fernández-Alba, Amadeo R

    2012-01-01

    In spite of high plant growth regulator application rates, little has been reported in the literature on determination of their residues in fruits and vegetables. This would be useful in monitoring good manufacturing practices and overall safety through the enforcement of maximum residue levels (MRLs). The present work describes method validation for the determination of 1-naphthylacetic acid (NAA) and 2(1-naphthyl)acetamide (NAAm) in tomato and zucchini using the mini-Luke, ethyl acetate (EtOAc) and acetate-buffered quick, easy, cheap, effective, rugged, and safe (QuEChERS) methods. Samples were spiked at two different levels: 50 and 100 pg/kg for NAA and 20 and 100 pg/kg for NAAm. These compounds were analyzed within the same chromatographic run with LC coupled to triple quadrupole MS (LC/(QqQ)MS/MS) in positive and negative electrospray ionization [ESI(+) and ESI(-)] modes for NAAm and NAA, respectively. For analyte confirmation, LC/ESI(-)QTOF-MS was also investigated given that NAA has only one multiple reaction monitoring transition (185.1-*140.9 m/z). These three common methods were used to determine linearity, recoveries, precision (RSD), matrix effects, repeatability, and reproducibility (n = 5) for the selected matrixes. In terms of the Directorate-General for Health and Consumers (DG-SANCO) guidelines, only insignificant differences were found for the multiresidue methods tested, regardless of the commodity. Matrix-matched calibration was used, and LODs were below 10.1 pg/kg for NAA and 6.0 pg/kg for NAAm, which were lower than the MRLs established in current European Union legislation for these compounds. Obtained recoveries for NAA ranged from 87 to 107% with RSD values below 10% for mini-Luke, 83 to 107% with RSD <11% for EtOAc, and 76 to 85% with RSD <7% for QuEChERS. NAAm recoveries ranged from 74 to 102% with RSD 5 15% for mini-Luke, 76 to 97% with RSD <4% for EtOAc, and 76 to 93% with RSD < 5% for QuEChERS. The linearity of the response over two orders of magnitude was demonstrated (r2 > 0.996) for all methods used. Good repeatability and reproducibility in terms of RSD were obtained (11.3-17.8%) for these analytical methods. The results were acceptable within the studied ranges for both analytes in all methods. As these multiresidue methods are used at the present time in many laboratories, this survey indicates that these analytes should be included in their monitoring scope.

  4. Effects of programming and healing temperatures on the healing efficiency of a confined healable polymer composite

    NASA Astrophysics Data System (ADS)

    Yougoubare, Y. Quentin; Pang, Su-Seng

    2014-02-01

    In previous work, a biomimetic close-then-heal (CTH) healing mechanism was proposed and validated to repeatedly heal wide-open cracks in load carrying engineering structures by using constrained expansion of compression programmed thermoset shape memory polymers (SMPs). In this study, the effects on healing efficiencies of variation of temperature during both thermomechanical programming and shape recovery (healing) under three-dimensional (3D) confinement are evaluated. The polymer considered is a polystyrene shape memory polymer with 6% by volume of thermoplastic particle additives (copolyester) dispersed in the matrix. In addition to the programming and healing temperatures, some of the parameters investigated include the flexural strength, crack width and elemental composition at the crack interface. It is observed that while increase of the programming temperature is slightly beneficial to strength recovery, most of the strength recovered and damage repair are strongly dependent on the healing temperature. The best healing efficiency (63%) is achieved by a combination of a programming temperature above the glass transition temperature of the polymer and a healing temperature above the bonding point of the copolyester.

  5. Laboratory simulation studies of steady-state and potential catalytic effects in the ROPE{trademark} process

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guffey, F.D.; Holper, P.A.

    The Western Research Institute is currently developing a process for the recovery of distillable liquid products from alternate fossil fuel sources such as tar sand and oil shale. The processing concept is based on recycling a fraction of the produced oil back into the reactor with the raw resource. This concept is termed the recycle oil pyrolysis and extraction (ROPE{sup TM}) process. The conversion of the alternate resource to a liquid fuel is performed in two stages. The first recovery stage is performed at moderate temperatures (325--420{degrees}C [617--788{degrees}F]) in the presence of product oil recycle. The second stage is performedmore » at higher temperatures (450--540{degrees}C [842--1004{degrees}F]) in the absence of product oil. The experiments reported here were performed Asphalt Ridge tar sand in the all-glass laboratory simulation reactor to simulate (1) the recycling of SAE 50 weight oil in the recycle oil pyrolysis zone and (2) to evaluate the potential catalytic effects of the sand matrix.« less

  6. Laboratory simulation studies of steady-state and potential catalytic effects in the ROPE trademark process

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guffey, F.D.; Holper, P.A.

    The Western Research Institute is currently developing a process for the recovery of distillable liquid products from alternate fossil fuel sources such as tar sand and oil shale. The processing concept is based on recycling a fraction of the produced oil back into the reactor with the raw resource. This concept is termed the recycle oil pyrolysis and extraction (ROPE{sup TM}) process. The conversion of the alternate resource to a liquid fuel is performed in two stages. The first recovery stage is performed at moderate temperatures (325--420{degrees}C (617--788{degrees}F)) in the presence of product oil recycle. The second stage is performedmore » at higher temperatures (450--540{degrees}C (842--1004{degrees}F)) in the absence of product oil. The experiments reported here were performed Asphalt Ridge tar sand in the all-glass laboratory simulation reactor to simulate (1) the recycling of SAE 50 weight oil in the recycle oil pyrolysis zone and (2) to evaluate the potential catalytic effects of the sand matrix.« less

  7. Matrix Effects on the Stability and Antioxidant Activity of Red Cabbage Anthocyanins under Simulated Gastrointestinal Digestion

    PubMed Central

    Podsędek, Anna; Koziołkiewicz, Maria

    2014-01-01

    Red cabbage is, among different vegetables, one of the major sources of anthocyanins. In the present study an in vitro digestion method has been used to assay the influence of the physiological conditions in the stomach and small intestine, as well as faecal microflora on anthocyanins stability in red cabbage and anthocyanin-rich extract. The recovery of anthocyanins during in vitro gastrointestinal digestion was strongly influenced by food matrix. The results showed that other constituents present in cabbage enhanced the stability of anthocyanins during the digestion. The amount of anthocyanins (HPLC method) and antioxidant capacity (ABTS and FRAP assays) strongly decreased after pancreatic-bile digestion in both matrices but total phenolics content (Folin-Ciocalteu assay) in these digestions was higher than in initial samples. Incubation with human faecal microflora caused further decline in anthocyanins content. The results obtained suggest that intact anthocyanins in gastric and products of their decomposition in small and large intestine may be mainly responsible for the antioxidant activity and other physiological effects after consumption of red cabbage. PMID:24575407

  8. PEG-chitosan hydrogel with tunable stiffness for study of drug response of breast cancer cells

    PubMed Central

    Chang, Fei-Chien; Tsao, Ching-Ting; Lin, Anqi; Zhang, Mengying; Levengood, Sheeny Lan; Zhang, Miqin

    2016-01-01

    Mechanical properties of the extracellular matrix have a profound effect on the behavior of anchorage-dependent cells. However, the mechanisms that define the effects of matrix stiffness on cell behavior remains unclear. Therefore, the development and fabrication of synthetic matrices with well-defined stiffness is invaluable for studying the interactions of cells with their biophysical microenvironment in vitro. We demonstrate a methoxypolyethylene glycol (mPEG)-modified chitosan hydrogel network where hydrogel stiffness can be easily modulated under physiological conditions by adjusting the degree of mPEG grafting onto chitosan (PEGylation). We show that the storage modulus of the hydrogel increases as PEGylation decreases and the gels exhibit instant self-recovery after deformation. Breast cancer cells cultured on the stiffest hydrogels adopt a more malignant phenotype with increased resistance to doxorubicin as compared with cells cultured on tissue culture polystyrene or Matrigel. This work demonstrates the utility of mPEG-modified chitosan hydrogel, with tunable mechanical properties, as an improved replacement of conventional culture system for in vitro characterization of breast cancer cell phenotype and evaluation of cancer therapies. PMID:27595012

  9. Platelet-Rich Plasma (PRP) for Acute Muscle Injury: A Systematic Review

    PubMed Central

    A. Hamid, Mohamad Shariff; Yusof, Ashril; Mohamed Ali, Mohamed Razif

    2014-01-01

    Introduction Acute muscle injury is one of the commonest injuries that often result in loss of training and competition time. The best management for muscle injury has not been identified. Sports medicine practitioners used several approaches in attempt to accelerate time to recovery from muscle injury. More recently growing interest focussed on autologous blood product injection. Methods A literature search was conducted systematically using OvidMEDLINE, PubMed, EMBASE, SPORTDiscus and CINAHL databases to retrieve articles published until December 2012. Controlled trials and controlled laboratory studies comparing different strategies to promote early recovery of muscle injury were included. The methodological quality of studies was assessed. Results There are limited studies on the effects of PRP therapy for muscle injury. Three in vivo laboratory studies and one pilot human study were reviewed. The laboratory studies reported histological evidence on significant acceleration of muscle healing in animals treated with autologous conditioned serum (ACS), platelet-rich plasma (PRP) and platelet rich fibrin matrix (PRFM). A pilot human study found athletes treated with repeated ACS injection recovers significantly faster than retrospective controls. Conclusion Several in vivo laboratory studies suggest beneficial effects of ACS, PRP and PRFM in accelerating muscle recovery. Evidence to suggest similar effects on humans is however limited, as valuable information from robust human controlled trials is still not available at this moment. Hence, more studies of satisfactory methodological quality with platelet-rich plasma interventions on muscle injury are justified. PMID:24587389

  10. BACTERIAL TRANSPORT THROUGH HOMOGENEOUS SOIL

    EPA Science Inventory

    The transport of microorganisms in soils is of major importance for bioremediation of subsurface polluted zones and for pollution of groundwater with pathogens. A procedure for evaluating the relative mobility and recovery of bacteria in the soil matrix was developed. In the meth...

  11. New environmentally friendly MSPD solid support based on golden mussel shell: characterization and application for extraction of organic contaminants from mussel tissue.

    PubMed

    Rombaldi, Caroline; de Oliveira Arias, Jean Lucas; Hertzog, Gabriel Ianzer; Caldas, Sergiane Souza; Vieira, João P; Primel, Ednei Gilberto

    2015-06-01

    The use of golden mussel shells as a solid support in vortex-assisted matrix solid-phase dispersion (MSPD) was evaluated for the first time for extraction of residues of 11 pesticides and nine pharmaceutical and personal care products from mussel tissue samples. After they had been washed, dried, and milled, the mussel shells were characterized by scanning electron microscopy, energy-dispersive X-ray spectroscopy, infrared spectroscopy, and Brunauer-Emmett-Teller analysis. The MSPD procedure with analysis by liquid chromatography-tandem mass spectrometry allowed the determination of target analytes at trace concentrations (nanograms per gram), with mean recoveries ranging from 61 to 107 % and relative standard deviations lower than 18 %. The optimized method consisted of dispersion of 0.5 g of mussel tissue, 0.5 g of NaSO4, and 0.5 g of golden mussel shell for 5 min, and subsequent extraction with 5 mL of ethyl acetate. The matrix effect was evaluated, and a low effect was found for all compounds. The results showed that mussel shell is an effective material and a less expensive material than materials that have traditionally been used, i.e., it may be used in the MSPD dispersion step during the extraction of pesticides and pharmaceutical and personal care products from golden mussel tissues. Graphical Abstract Vortex-assited matrix solid-phase dispersion for extraction of 11 pesticides and 9 PPCPs care products from mussel tissue samples.

  12. Sample Preparation and Extraction in Small Sample Volumes Suitable for Pediatric Clinical Studies: Challenges, Advances, and Experiences of a Bioanalytical HPLC-MS/MS Method Validation Using Enalapril and Enalaprilat

    PubMed Central

    Burckhardt, Bjoern B.; Laeer, Stephanie

    2015-01-01

    In USA and Europe, medicines agencies force the development of child-appropriate medications and intend to increase the availability of information on the pediatric use. This asks for bioanalytical methods which are able to deal with small sample volumes as the trial-related blood lost is very restricted in children. Broadly used HPLC-MS/MS, being able to cope with small volumes, is susceptible to matrix effects. The latter restrains the precise drug quantification through, for example, causing signal suppression. Sophisticated sample preparation and purification utilizing solid-phase extraction was applied to reduce and control matrix effects. A scale-up from vacuum manifold to positive pressure manifold was conducted to meet the demands of high-throughput within a clinical setting. Faced challenges, advances, and experiences in solid-phase extraction are exemplarily presented on the basis of the bioanalytical method development and validation of low-volume samples (50 μL serum). Enalapril, enalaprilat, and benazepril served as sample drugs. The applied sample preparation and extraction successfully reduced the absolute and relative matrix effect to comply with international guidelines. Recoveries ranged from 77 to 104% for enalapril and from 93 to 118% for enalaprilat. The bioanalytical method comprising sample extraction by solid-phase extraction was fully validated according to FDA and EMA bioanalytical guidelines and was used in a Phase I study in 24 volunteers. PMID:25873972

  13. Improved self-healing of polyethylene/carbon black nanocomposites by their shape memory effect.

    PubMed

    Wang, Xiaoyan; Zhao, Jun; Chen, Min; Ma, Lan; Zhao, Xiaodong; Dang, Zhi-Min; Wang, Zhenwen

    2013-02-07

    In this work, the improved self-healing of cross-linked polyethylene (PE) (cPE)/carbon black (CB) nanocomposites by their shape memory effect (SME) is investigated. CB nanoparticles are found to be homogeneously dispersed in the PE matrix and significantly increase the strength of the materials. Compared with the breaking of linear PE (lPE) at the melting temperature (T(m)), the cPE and cPE/CB nanocomposites still have high strength above T(m) due to the formation of networks. The cPE and cPE/CB nanocomposites show both high strain fixity ratio (R(f)) and high strain recovery ratio (R(r)). Crystallization-induced elongation is observed for all the prepared shape memory polymer (SMP) materials and the effect becomes less remarkable with increasing volume fraction of CB nanoparticles (v(CB)). The scratch self-healing tests show that the cross-linking of PE matrix, the addition of CB nanoparticles, and the previous stretching in the direction perpendicular to the scratch favor the closure of the scratch and its complete healing. This SME-aided self-healing could have potential applications in diverse fields such as coating and structure materials.

  14. Preconcentration of heavy metals on activated carbon and their determination in fruits by inductively coupled plasma optical emission spectrometry.

    PubMed

    Feist, Barbara; Mikula, Barbara

    2014-03-15

    A method of separation and preconcentration of cadmium, cobalt, copper, nickel, lead, and zinc at trace level using activated carbon is proposed. Activated carbon with the adsorbed trace metals was mineralised using a high-pressure microwave mineraliser. The heavy metals were determined after preconcentration by inductively coupled plasma optical emission spectrometry (ICP-OES). The influence of several parameters, such as pH, sorbent mass, shaking time was examined. Moreover, effects of inorganic matrix on recovery of the determined elements were studied. The experiment shows that foreign ions did not influence recovery of the determined elements. The detection limits (DL) of Cd, Co, Cu, Ni, Pb, and Zn were 0.17, 0.19, 1.60, 2.60, 0.92 and 1.50 μg L(-)(1), respectively. The recovery of the method for the determined elements was better than 95% with relative standard deviation from 1.3% to 3.7%. The preconcentration factor was 80. The proposed method was applied for determination of Cd, Co, Cu, Ni, Pb, and Zn in fruits materials. Accuracy of the proposed method was verified using certified reference material (NCS ZC85006 Tomato). Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. Determination of atrazine and its major degradation products in soil pore water by solid-phase extraction, chemical derivatization, and gas chromatography/mass spectrometry

    USGS Publications Warehouse

    Carter, D.S.

    1996-01-01

    This report describes a method for the determination of atrazine, desethylatrazine, deisopropylatrazine, didealkylatrazine, and hydroxyatrazine from soil pore waters by use of solid-phase extractionfollowed by chemical derivatization and gas chromatography/mass spectrometry. The analytes are isolated from the pore-water matrix byextraction onto a graphitized carbon-black cartridge. The cartridge is dried under vacuum, and adsorbed analytes are removed by elution with ethyl acetate followed by dichloromethane/methanol (7:3, volume/volume). Water is removed from the ethyl acetate fraction on an anhydrous sodium sulfate column. The combined fractions are solvent exchanged into acetonitrile, evaporated by use of a nitrogen stream, and derivatized by use of N- methyl-N-(tert-butyldimethylsilyl)- trifluoroacetamide. The derivatized extracts are analyzed by capillary-column gaschromatography/electron-impact mass spectrometry in the scan mode. Estimated method detection limits range from 0.03 to 0.07 micrograms per liter. The mean recoveries of all analytes and surrogates determined at 0.74 to 0.82 micrograms per liter in reagent water in soil pore water were 94 percent and 98 percent, respectively. The mean recoveries of all analytes and surrogates determined at 7.4 to 8.2 micrograms per liter in reagent water and in soil pore water were 96 percent and 97 percent,respectively. Recoveries were 90 percent or higher, regardless of analyte concentration or matrix composition, for all compounds excepthydroxyatrazine, whose recoveries were slightly lower (77 percent) at the low concentration.

  16. Harnessing data structure for recovery of randomly missing structural vibration responses time history: Sparse representation versus low-rank structure

    NASA Astrophysics Data System (ADS)

    Yang, Yongchao; Nagarajaiah, Satish

    2016-06-01

    Randomly missing data of structural vibration responses time history often occurs in structural dynamics and health monitoring. For example, structural vibration responses are often corrupted by outliers or erroneous measurements due to sensor malfunction; in wireless sensing platforms, data loss during wireless communication is a common issue. Besides, to alleviate the wireless data sampling or communication burden, certain accounts of data are often discarded during sampling or before transmission. In these and other applications, recovery of the randomly missing structural vibration responses from the available, incomplete data, is essential for system identification and structural health monitoring; it is an ill-posed inverse problem, however. This paper explicitly harnesses the data structure itself-of the structural vibration responses-to address this (inverse) problem. What is relevant is an empirical, but often practically true, observation, that is, typically there are only few modes active in the structural vibration responses; hence a sparse representation (in frequency domain) of the single-channel data vector, or, a low-rank structure (by singular value decomposition) of the multi-channel data matrix. Exploiting such prior knowledge of data structure (intra-channel sparse or inter-channel low-rank), the new theories of ℓ1-minimization sparse recovery and nuclear-norm-minimization low-rank matrix completion enable recovery of the randomly missing or corrupted structural vibration response data. The performance of these two alternatives, in terms of recovery accuracy and computational time under different data missing rates, is investigated on a few structural vibration response data sets-the seismic responses of the super high-rise Canton Tower and the structural health monitoring accelerations of a real large-scale cable-stayed bridge. Encouraging results are obtained and the applicability and limitation of the presented methods are discussed.

  17. Differential retention and release of CO 2 and CH 4 in kerogen nanopores: Implications for gas extraction and carbon sequestration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ho, Tuan Anh; Wang, Yifeng; Xiong, Yongliang

    Methane (CH 4) and carbon dioxide (CO 2), the two major components generated from kerogen maturation, are stored dominantly in nanometer-sized pores in shale matrix as (1) a compressed gas, (2) an adsorbed surface species and/or (3) a species dissolved in pore water (H 2O). In addition, supercritical CO 2 has been proposed as a fracturing fluid for simultaneous enhanced oil/gas recovery (EOR) and carbon sequestration. A mechanistic understanding of CH 4-CO 2-H 2O interactions in shale nanopores is critical for designing effective operational processes. Using molecular simulations, we show that kerogen preferentially retains CO 2 over CH 4 andmore » that the majority of CO 2 either generated during kerogen maturation or injected in EOR will remain trapped in the kerogen matrix. The trapped CO 2 may be released only if the reservoir pressure drops below the supercritical CO 2 pressure. When water is present in the kerogen matrix, it may block CH 4 release. Furthermore, the addition of CO 2 may enhance CH 4 release because CO 2 can diffuse through water and exchange for adsorbed methane in the kerogen nanopores.« less

  18. Direction of Arrival Estimation for MIMO Radar via Unitary Nuclear Norm Minimization

    PubMed Central

    Wang, Xianpeng; Huang, Mengxing; Wu, Xiaoqin; Bi, Guoan

    2017-01-01

    In this paper, we consider the direction of arrival (DOA) estimation issue of noncircular (NC) source in multiple-input multiple-output (MIMO) radar and propose a novel unitary nuclear norm minimization (UNNM) algorithm. In the proposed method, the noncircular properties of signals are used to double the virtual array aperture, and the real-valued data are obtained by utilizing unitary transformation. Then a real-valued block sparse model is established based on a novel over-complete dictionary, and a UNNM algorithm is formulated for recovering the block-sparse matrix. In addition, the real-valued NC-MUSIC spectrum is used to design a weight matrix for reweighting the nuclear norm minimization to achieve the enhanced sparsity of solutions. Finally, the DOA is estimated by searching the non-zero blocks of the recovered matrix. Because of using the noncircular properties of signals to extend the virtual array aperture and an additional real structure to suppress the noise, the proposed method provides better performance compared with the conventional sparse recovery based algorithms. Furthermore, the proposed method can handle the case of underdetermined DOA estimation. Simulation results show the effectiveness and advantages of the proposed method. PMID:28441770

  19. Role of tumor–host interactions in interstitial diffusion of macromolecules: Cranial vs. subcutaneous tumors

    PubMed Central

    Pluen, Alain; Boucher, Yves; Ramanujan, Saroja; McKee, Trevor D.; Gohongi, Takeshi; di Tomaso, Emmanuelle; Brown, Edward B.; Izumi, Yotaro; Campbell, Robert B.; Berk, David A.; Jain, Rakesh K.

    2001-01-01

    The large size of many novel therapeutics impairs their transport through the tumor extracellular matrix and thus limits their therapeutic effectiveness. We propose that extracellular matrix composition, structure, and distribution determine the transport properties in tumors. Furthermore, because the characteristics of the extracellular matrix largely depend on the tumor–host interactions, we postulate that diffusion of macromolecules will vary with tumor type as well as anatomical location. Diffusion coefficients of macromolecules and liposomes in tumors growing in cranial windows (CWs) and dorsal chambers (DCs) were measured by fluorescence recovery after photobleaching. For the same tumor types, diffusion of large molecules was significantly faster in CW than in DC tumors. The greater diffusional hindrance in DC tumors was correlated with higher levels of collagen type I and its organization into fibrils. For molecules with diameters comparable to the interfibrillar space the diffusion was 5- to 10-fold slower in DC than in CW tumors. The slower diffusion in DC tumors was associated with a higher density of host stromal cells that synthesize and organize collagen type I. Our results point to the necessity of developing site-specific drug carriers to improve the delivery of molecular medicine to solid tumors. PMID:11274375

  20. Differential retention and release of CO 2 and CH 4 in kerogen nanopores: Implications for gas extraction and carbon sequestration

    DOE PAGES

    Ho, Tuan Anh; Wang, Yifeng; Xiong, Yongliang; ...

    2018-02-06

    Methane (CH 4) and carbon dioxide (CO 2), the two major components generated from kerogen maturation, are stored dominantly in nanometer-sized pores in shale matrix as (1) a compressed gas, (2) an adsorbed surface species and/or (3) a species dissolved in pore water (H 2O). In addition, supercritical CO 2 has been proposed as a fracturing fluid for simultaneous enhanced oil/gas recovery (EOR) and carbon sequestration. A mechanistic understanding of CH 4-CO 2-H 2O interactions in shale nanopores is critical for designing effective operational processes. Using molecular simulations, we show that kerogen preferentially retains CO 2 over CH 4 andmore » that the majority of CO 2 either generated during kerogen maturation or injected in EOR will remain trapped in the kerogen matrix. The trapped CO 2 may be released only if the reservoir pressure drops below the supercritical CO 2 pressure. When water is present in the kerogen matrix, it may block CH 4 release. Furthermore, the addition of CO 2 may enhance CH 4 release because CO 2 can diffuse through water and exchange for adsorbed methane in the kerogen nanopores.« less

  1. Development and Interlaboratory Study of a Liquid Chromatography Tandem Mass Spectrometric Methodfor the Determination of Multiple Mycotoxins inCereals Using Stable Isotope Dilution.

    PubMed

    Ye, Jin; Wu, Yu; Guo, Qilei; Lu, Meiling; Wang, Songshan; Xin, Yuanyuan; Xie, Gang; Zhang, Yan; Mariappan, Meena; Wang, Songxue

    2018-05-01

    An efficient, rapid, accurate, and cost-effective method based on stable isotope dilution and LC tandem MS was developed for the determination of multimycotoxins in cereals. The samples were extracted using acetonitrile-water-acetic acid (70 + 29 + 1, v/v/v), followed by dilution and centrifugation without any further cleanup. The mycotoxins were separated on a C18 column. Interference due to matrix effects was efficiently compensated for with [13C]-labeled stable isotope internal standards. The method demonstrated excellent linear relations, with regression coefficients above 0.999. Spiked recoveries at three different concentrations ranged from 80.9 to 115.9%, and RSDs were below 14% for all mycotoxins. The trueness of the method was also verified by participating in two proficiency tests, and satisfactory z-scores (|z| < 1.1) were obtained. In addition, an international interlaboratory study was organized to evaluate the methods. Eight laboratories characterized recovery, repeatability, and reproducibility studies in wheat, maize, and barley. The interlaboratory results were analyzed according to ISO 5725-2. Cochran and Grubbs tests were used to remove outliers. The mean recoveries of all 16 mycotoxins ranged from 87 to 111%. Repeatability, reproducibility, and Horwitz ratio values were 3.5-16.2, 5.4-33.6, and 0.16-1.65%, respectively. The results demonstrate that the method is reliable to determine multimycotoxins in cereals.

  2. Graft copolymers of ethyl methacrylate on waxy maize starch derivatives as novel excipients for matrix tablets: physicochemical and technological characterisation.

    PubMed

    Marinich, J A; Ferrero, C; Jiménez-Castellanos, M R

    2009-05-01

    Nowadays, graft copolymers are being used as an interesting option when developing a direct compression excipient for controlled release matrix tablets. New graft copolymers of ethyl methacrylate (EMA) on waxy maize starch (MS) and hydroxypropylstarch (MHS) were synthesised by free radical polymerization and alternatively dried in a vacuum oven (OD) or freeze-dried (FD). This paper evaluates the performance of these new macromolecules and discusses the effect of the carbohydrate nature and drying process on their physicochemical and technological properties. Grafting of EMA on the carbohydrate backbone was confirmed by IR and NMR spectroscopy, and the grafting yields revealed that graft copolymers present mainly a hydrophobic character. The graft copolymerization also leads to more amorphous materials with larger particle size and lower apparent density and water content than carbohydrates (MS, MHS). All the products show a lack of flow, except MHSEMA derivatives. MSEMA copolymers underwent much plastic flow and less elastic recovery than MHSEMA copolymers. Concerning the effect of drying method, FD derivatives were characterised by higher plastic deformation and less elasticity than OD derivatives. Tablets obtained from graft copolymers showed higher crushing strength and disintegration time than tablets obtained from raw starches. This behaviour suggests that these copolymers could be used as excipients in matrix tablets obtained by direct compression and with a potential use in controlled release.

  3. Fast methodology for the reliable determination of nonylphenol in water samples by minimal labeling isotope dilution mass spectrometry.

    PubMed

    Fabregat-Cabello, Neus; Castillo, Ángel; Sancho, Juan V; González, Florenci V; Roig-Navarro, Antoni Francesc

    2013-08-02

    In this work we have developed and validated an accurate and fast methodology for the determination of 4-nonylphenol (technical mixture) in complex matrix water samples by UHPLC-ESI-MS/MS. The procedure is based on isotope dilution mass spectrometry (IDMS) in combination with isotope pattern deconvolution (IPD), which provides the concentration of the analyte directly from the spiked sample without requiring any methodological calibration graph. To avoid any possible isotopic effect during the analytical procedure the in-house synthesized (13)C1-4-(3,6-dimethyl-3-heptyl)phenol was used as labeled compound. This proposed surrogate was able to compensate the matrix effect even from wastewater samples. A SPE pre-concentration step together with exhaustive efforts to avoid contamination were included to reach the signal-to-noise ratio necessary to detect the endogenous concentrations present in environmental samples. Calculations were performed acquiring only three transitions, achieving limits of detection lower than 100ng/g for all water matrix assayed. Recoveries within 83-108% and coefficients of variation ranging from 1.5% to 9% were obtained. On the contrary a considerable overestimation was obtained with the most usual classical calibration procedure using 4-n-nonylphenol as internal standard, demonstrating the suitability of the minimal labeling approach. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. Upscaling Multiphase Fluid Flow in Naturally Fractured Reservoirs

    NASA Astrophysics Data System (ADS)

    Matthai, S.; Maghami-Nick, H.; Belayneh, M.; Geiger, S.

    2009-04-01

    Hydrocarbon recovery from fractured porous reservoirs is difficult to predict as it depends on the focusing of the flow and the local balance of viscous, gravitational, and capillary forces. Hecto-metre scale sub-volumes of fractured oil reservoirs contain thousands of fractures with highly variable flow properties, dimensions and orientations. This complexity precludes direct geometric incorporation into field scale multiphase flow models. Macroscopic laws of their integral effects on multiphase flow are required. These can be investigated by DFM (discrete fracture and matrix) numerical simulations based on discrete fracture models representing fractured reservoir analogues. Here we present DFM results indicating that hecto-metre-scale relative permeability, the time to water breakthrough, and the subsequent water cut primarily depend on the fracture-to-rock matrix flux ratio, qf/qm, quantifying the proportion of the cross-sectional flux that occurs through the fractures. Relative permeability during imbibition runs is best approximated by a rate-dependent new model taking into account capillary fracture-matrix transfer. The up-scaled fractional flow function fo(sw) derived from this new kri formulation is convex with a near-infinity slope at the residual water saturation. This implies that the hector-metre scale spatially averaged Buckley-Leverett equation for fractured porous media does not contain a shock, but a long leading edge in the averaged profile of the invading phase. This dispersive behaviour marks the progressively widening saturation front and an early water breakthrough observed in the discrete fracture reservoir analogues. Since fracture porosity φf is usually only a fraction of a percent, a cross-over from krw < kro to krw/kro ≈ qf/qm occurs after the first few percent of recovery, and because qf/qm ranges between 10-1,000, sweep efficiency ignoring the positive influence of counter-current imbibition is extremely low. The accuracy of reservoir performance predictions by the proposed fo(sw) up-scaling methodology depends on how well φf , qf/qm and a new parameter termed fraction of fracture matrix interface area in contact with the invading fluid, XA,if(si) can be constrained under in situ conditions.

  5. Accurate quantification of PGE2 in the polyposis in rat colon (Pirc) model by surrogate analyte-based UPLC-MS/MS.

    PubMed

    Yun, Changhong; Dashwood, Wan-Mohaiza; Kwong, Lawrence N; Gao, Song; Yin, Taijun; Ling, Qinglan; Singh, Rashim; Dashwood, Roderick H; Hu, Ming

    2018-01-30

    An accurate and reliable UPLC-MS/MS method is reported for the quantification of endogenous Prostaglandin E2 (PGE 2 ) in rat colonic mucosa and polyps. This method adopted the "surrogate analyte plus authentic bio-matrix" approach, using two different stable isotopic labeled analogs - PGE 2 -d9 as the surrogate analyte and PGE 2 -d4 as the internal standard. A quantitative standard curve was constructed with the surrogate analyte in colonic mucosa homogenate, and the method was successfully validated with the authentic bio-matrix. Concentrations of endogenous PGE 2 in both normal and inflammatory tissue homogenates were back-calculated based on the regression equation. Because of no endogenous interference on the surrogate analyte determination, the specificity was particularly good. By using authentic bio-matrix for validation, the matrix effect and exaction recovery are identically same for the quantitative standard curve and actual samples - this notably increased the assay accuracy. The method is easy, fast, robust and reliable for colon PGE 2 determination. This "surrogate analyte" approach was applied to measure the Pirc (an Apc-mutant rat kindred that models human FAP) mucosa and polyps PGE 2 , one of the strong biomarkers of colorectal cancer. A similar concept could be applied to endogenous biomarkers in other tissues. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Alterations in Protein Expression in Tree Shrew Sclera during Development of Lens-Induced Myopia and Recovery

    PubMed Central

    Norton, Thomas T.

    2012-01-01

    Purpose. During the development of, and recovery from, negative lens-induced myopia there is regulated remodeling of the scleral extracellular matrix (ECM) that controls the extensibility of the sclera. Difference gel electrophoresis (DIGE) was used to identify and categorize proteins whose levels are altered in this process. Methods. Two groups of five tree shrews started monocular lens wear 24 days after eye opening (days of visual experience [VE]). The lens-induced myopia (LIM) group wore a −5 D lens for 4 days. The recovery (REC) group wore a −5 D lens for 11 days and then recovered for 4 days. Two normal groups (28 and 39 days of VE; n = 5 each) were also examined, age-matched to each of the treatment groups. Refractive and A-scan measures confirmed the effect of the treatments. Scleral proteins were isolated and resolved by DIGE. Proteins that differed in abundance were identified by mass spectrometry. Ingenuity pathway analysis was used to investigate potential biological pathway interactions. Results. During normal development (28–39 days of VE), eight proteins decreased and one protein increased in relative abundance. LIM-treated eyes were myopic and longer than control eyes; LIM-control eyes were slightly myopic compared with 28N eyes, indicating a yoking effect. In both the LIM-treated and the LIM-control eyes, there was a general downregulation from normal of proteins involved in transcription, cell adhesion, and protein synthesis. Additional proteins involved in cell adhesion, actin cytoskeleton, transcriptional regulation, and ECM structural proteins differed in the LIM-treated eyes versus normal but did not differ in the control eyes versus normal. REC-treated eyes were recovering from the induced myopia. REC-control eye refractions were not significantly different from the 39N eyes, and few proteins differed from age-matched normal eyes. The balance of protein expression in the REC-treated eyes, compared with normal eyes and REC-control eyes, shifted toward upregulation or a return to normal levels of proteins involved in cell adhesion, cell division, cytoskeleton, and ECM structural proteins, including upregulation of several cytoskeleton-related proteins not affected during myopia development. Conclusions. The DIGE procedure revealed new proteins whose abundance is altered during myopia development and recovery. Many of these are involved in cell-matrix adhesions, cytoskeleton, and transcriptional regulation and extend our understanding of the remodeling that controls the extensibility of the sclera. Reductions in these proteins during minus lens wear may produce the increased scleral viscoelasticity that results in faster axial elongation. Recovery is not a mirror image of lens-induced myopia—many protein levels, decreased during LIM, returned to normal, or slightly above normal, and additional cytoskeleton proteins were upregulated. However, no single protein or pathway appeared to be responsible for the scleral changes during myopia development or recovery. PMID:22039233

  7. Analysis of pharmaceutical and other organic wastewater compounds in filtered and unfiltered water samples by gas chromatography/mass spectrometry

    USGS Publications Warehouse

    Zaugg, Steven D.; Phillips, Patrick J.; Smith, Steven G.

    2014-01-01

    Research on the effects of exposure of stream biota to complex mixtures of pharmaceuticals and other organic compounds associated with wastewater requires the development of additional analytical capabilities for these compounds in water samples. Two gas chromatography/mass spectrometry (GC/MS) analytical methods used at the U.S. Geological Survey National Water Quality Laboratory (NWQL) to analyze organic compounds associated with wastewater were adapted to include additional pharmaceutical and other organic compounds beginning in 2009. This report includes a description of method performance for 42 additional compounds for the filtered-water method (hereafter referred to as the filtered method) and 46 additional compounds for the unfiltered-water method (hereafter referred to as the unfiltered method). The method performance for the filtered method described in this report has been published for seven of these compounds; however, the addition of several other compounds to the filtered method and the addition of the compounds to the unfiltered method resulted in the need to document method performance for both of the modified methods. Most of these added compounds are pharmaceuticals or pharmaceutical degradates, although two nonpharmaceutical compounds are included in each method. The main pharmaceutical compound classes added to the two modified methods include muscle relaxants, opiates, analgesics, and sedatives. These types of compounds were added to the original filtered and unfiltered methods largely in response to the tentative identification of a wide range of pharmaceutical and other organic compounds in samples collected from wastewater-treatment plants. Filtered water samples are extracted by vacuum through disposable solid-phase cartridges that contain modified polystyrene-divinylbenzene resin. Unfiltered samples are extracted by using continuous liquid-liquid extraction with dichloromethane. The compounds of interest for filtered and unfiltered sample types were determined by use of the capillary-column gas chromatography/mass spectrometry. The performance of each method was assessed by using data on recoveries of compounds in fortified surface-water, wastewater, and reagent-water samples. These experiments (referred to as spike experiments) consist of fortifying (or spiking) samples with known amounts of target analytes. Surface-water-spike experiments were performed by using samples obtained from a stream in Colorado (unfiltered method) and a stream in New York (filtered method). Wastewater spike experiments for both the filtered and unfiltered methods were performed by using a treated wastewater obtained from a single wastewater treatment plant in New York. Surface water and wastewater spike experiments were fortified at both low and high concentrations and termed low- and high-level spikes, respectively. Reagent water spikes were assessed in three ways: (1) set spikes, (2) a low-concentration fortification experiment, and (3) a high-concentration fortification experiment. Set spike samples have been determined since 2009, and consist of analysis of fortified reagent water for target compounds included for each group of 10 to18 environmental samples analyzed at the NWQL. The low-concentration and high-concentration reagent spike experiments, by contrast, represent a one-time assessment of method performance. For each spike experiment, mean recoveries ranging from 60 to 130 percent indicate low bias, and relative standard deviations (RSDs) less than ( Of the compounds included in the filtered method, 21 had mean recoveries ranging from 63 to 129 percent for the low-level and high-level surface-water spikes, and had low ()132 percent]. For wastewater spikes, 24 of the compounds included in the filtered method had recoveries ranging from 61 to 130 percent for the low-level and high-level spikes. RSDs were 130 percent) or variable recoveries (RSDs >30 percent) for low-level wastewater spikes, or low recoveries ( Of the compounds included in the unfiltered method, 17 had mean spike recoveries ranging from 74 to 129 percent and RSDs ranging from 5 to 25 percent for low-level and high-level surface water spikes. The remaining compounds had poor mean recoveries (130 percent), or high RSDs (>29 percent) for these spikes. For wastewater, 14 of the compounds included in the unfiltered method had mean recoveries ranging from 62 to 127 percent and RSDs 130 percent), or low mean recoveries (33 percent) for the low-level wastewater spikes. Of the compounds found in wastewater, 24 had mean set spike recoveries ranging from 64 to 104 percent and RSDs Separate method detection limits (MDLs) were computed for surface water and wastewater for both the filtered and unfiltered methods. Filtered method MDLs ranged from 0.007 to 0.14 microgram per liter (μg/L) for the surface water matrix and from 0.004 to 0.62 μg/L for the wastewater matrix. Unfiltered method MDLs ranged from 0.014 to 0.33 μg/L for the surface water matrix and from 0.008 to 0.36 μg/L for the wastewater matrix.

  8. An LC-MS/MS method for simultaneous determination of nine steroidal saponins from Paris polyphylla var. in rat plasma and its application to pharmacokinetic study.

    PubMed

    Yang, Guangyi; Lu, Wei; Pan, Meng; Zhang, Chenning; Zhou, Yuan; Hu, Pei; Hu, Ming; Song, Gao

    2017-10-25

    Paris polyphylla var is an herbal plant herb widely used in Traditional Chinese Medicine. The purpose of this study is to develop an Ultra Performance Liquid Chromatography-tandem mass spectrometer (UPLC-MS) method to quantify the major components (i.e., nine saponins) from P. polyphylla in plasma samples. A UItra BiPh column (100×2.1mm, 5μm) was used with acetonitrile/0.1% formic acid in water as mobile phases. The analytes were quantified using a Waters XEVO TQ mass spectrometer via multiple reaction monitoring (MRM) with positive scan mode. A protein precipitation method was used to extract the analytes from rat plasma. The inter/intra-day precision, accuracy, recovery, matrix effect, and stability were evaluated per the FDA guidance. The method showed linearity in the concentration ranges of 2.4-1250ng/mL. The intra-day and inter-day precisions (RSD) of these analytes at three different levels were less than 15.0%. The extraction recoveries of these analytes were from 83.8% to 109.4% and the matrix effects ranged from 87.4% to 105.4%. The stabilities of these compounds in plasma were evaluated by analyzing three different concentrations following storage at 25°C for 6h, and -80°C for 30days. All the samples displayed less than 15.0% variations. The validated method was successfully used to a pharmacokinetic (PK) study using Sprague Dawley (SD) rats with intravenous (i.v.) and oral (p.o.) administration of P. polyphylla extract. The applications revealed that this method can be used to analyze major steroidal saponins from P. polyphylla in biological samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Multiresidue determination of pesticides in tea by gas chromatography-tandem mass spectrometry.

    PubMed

    Saito-Shida, Shizuka; Nemoto, Satoru; Teshima, Reiko

    2015-01-01

    An efficient and reliable GC-MS/MS method for the multiresidue determination of pesticides in tea was developed by modifying the Japanese official multiresidue method. Sample preparation was carefully optimized for the efficient removal of coextracted matrix components. The optimal sample preparation procedure involved swelling of the sample in water; extraction with acetonitrile; removal of water by salting-out; and sequential cleanup by ODS, graphitized carbon black/primary secondary amine (GCB/PSA) and silica gel cartridges prior to GC-MS/MS analysis. The recoveries of 162 pesticides from fortified (at 0.01 mg kg(-1)) green tea, oolong tea, black tea and matcha (powdered green tea) were mostly (95-98% of the tested pesticides) within the range of 70-120%, with relative standard deviations of <20%. Poor recovery of triazole pesticides was considered to be due to low recovery from the silica gel cartridges. The test solutions obtained by the modified method contained relatively small amounts of pigments, caffeine and other matrix components and were cleaner than those obtained by the original Japanese official multiresidue method. No interfering peaks were observed in the blank chromatograms, indicating the high selectivity of the modified method. The overall results suggest that the developed method is suitable for the quantitative analysis of GC-amenable pesticide residues in tea.

  10. Polylactide-based polyurethane shape memory nanocomposites (Fe3O4/PLAUs) with fast magnetic responsiveness

    NASA Astrophysics Data System (ADS)

    Gu, Shu-Ying; Jin, Sheng-Peng; Gao, Xie-Feng; Mu, Jian

    2016-05-01

    Polylactide-based polyurethane shape memory nanocomposites (Fe3O4/PLAUs) with fast magnetic responsiveness are presented. For the purpose of fast response and homogeneous dispersion of magnetic nanoparticles, oleic acid was used to improve the dispersibility of Fe3O4 nanoparticles in a polymer matrix. A homogeneous distribution of Fe3O4 nanoparticles in the polymer matrix was obtained for nanocomposites with low Fe3O4 loading content. A small agglomeration was observed for nanocomposites with 6 wt% and 9 wt% loading content, leading to a small decline in the mechanical properties. PLAU and its nanocomposites have glass transition around 52 °C, which can be used as the triggering temperature. PLAU and its nanocomposites have shape fixity ratios above 99%, shape recovery ratios above 82% for the first cycle and shape recovery ratios above 91% for the second cycle. PLAU and its nanocomposites also exhibit a fast water bath or magnetic responsiveness. The magnetic recovery time decreases with an increase in the loading content of Fe3O4 nanoparticles due to an improvement in heating performance for increased weight percentage of fillers. The nanocomposites have fast responses in an alternating magnetic field and have potential application in biomedical areas such as intravascular stent.

  11. Stroke Repair via Biomimicry of the Subventricular Zone

    NASA Astrophysics Data System (ADS)

    Matta, Rita; Gonzalez, Anjelica L.

    2018-03-01

    Stroke is among the leading causes of death and disability worldwide, 85% of which are ischemic. Current stroke therapies are limited by a narrow effective therapeutic time and fail to effectively complete the recovery of the damaged area. Magnetic resonance imaging of the subventricular zone (SVZ) following infarct/stroke has allowed visualization of new axonal connections and projections being formed, while new immature neurons migrate from the SVZ to the peri-infarct area. Such studies suggest that the SVZ is a primary source of regenerative cells for the repair and regeneration of stroke-damaged neurons and tissue. Therefore, the development of tissue engineered scaffolds that serve as a bioreplicative SVZ niche would support the survival of multiple cell types that reside in the SVZ. Essential to replication of the human SVZ microenvironment is the establishment of microvasculature that regulates both the healthy and stroke-injured blood brain barrier, which is dysregulated post-stroke. In order to reproduce this niche, understanding how cells interact in this environment is critical, in particular neural stem cells, endothelial cells, pericytes, ependymal cells, and microglia. Remodeling and repair of the matrix-rich SVZ niche by endogenous reparative mechanisms may then support functional recovery when enhanced by an artificial niche that supports the survival and proliferation of migrating vascular and neuronal cells. Critical considerations to mimic this area include an understanding of resident cell types, delivery method, and the use of biocompatible materials. Controlling stem cell survival, differentiation, and migration are key factors to consider when transplanting stem cells. Here, we discuss the role of the SVZ architecture and resident cells in the promotion and enhancement of endogenous repair mechanisms. We elucidate the interplay between the extracellular matrix composition and cell interactions prior to and following stroke. Lastly, we review current cell and neuronal niche biomimetic materials that allow for a tissue- engineered approach in order to promote structural and functional restoration of neural circuitry. By creating an artificial mimetic SVZ, tissue engineers can strive to facilitate tissue regeneration and functional recovery.

  12. Analytical method validation to evaluate dithiocarbamates degradation in biobeds in South of Brazil.

    PubMed

    Vareli, Catiucia S; Pizzutti, Ionara R; Gebler, Luciano; Cardoso, Carmem D; Gai, Daniela S H; Fontana, Marlos E Z

    2018-07-01

    In order to evaluate the efficiency of biobeds on DTC degradation, the aim of this study was to apply, optimize and validate a method to determine dithiocarbamate (mancozeb) in biobeds using gas chromatography-tandem mass spectrometry (GC-MS). The DTC pesticide mancozeb was hydrolysed in a tin (II) chloride solution at 1.5% in HCl (4 mol L -1 ), during 1 h in a water bath at 80 °C, and the CS 2 formed was extracted in isooctane. After cooling, 1 mL of the organic layer was transferred to an auto sampler vial and analyzed by GC-MS. A complete validation study was performed and the following parameters were assessed: linearity of the analytical curve (r 2 ), estimated method and instrument limits of detection and limits of quantification (LODm, LODi, LOQm and LOQi, respectively), accuracy (recovery%), precision (RSD%) and matrix effects. Recovery experiments were carried out with a standard spiking solution of the DTC pesticide thiram. Blank biobed (biomixture) samples were spiked at the three levels corresponding to the CS 2 concentrations of 1, 3 and 5 mg kg -1 , with seven replicates each (n = 7). The method presented satisfactory accuracy, with recoveries within the range of 89-96% and RSD ≤ 11%. The analytical curves were linear in the concentration range of 0.05-10 µg CS 2 mL -1 (r 2 > 0.9946). LODm and LOQm were 0.1 and 0.5 mg CS 2 kg -1 , respectively, and the calculated matrix effects were not significant (≤ 20%). The validated method was applied to 80 samples (biomixture), from sixteen different biobeds (collected at five sampling times) during fourteen months. Ten percent of samples presented CS 2 concentration below the LOD (0.1 mg CS 2 kg -1 ) and 49% of them showed results below the LOQ (0.5 mg CS 2 kg -1 ), which demonstrates the biobeds capability to degrade DTC. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Capillary-Channeled Polymer (C-CP) Fibers as a Stationary Phase for Sample Clean-Up of Protein Solutions for Matrix-Assisted Laser/Desorption Ionization Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Manard, Benjamin T.; Marcus, R. Kenneth

    2012-08-01

    Capillary-channeled polymer (C-CP) fibers are employed in a micropipette tip format to affect a stationary phase for the solid phase extraction (SPE) of proteins from buffer solutions prior to MALDI-MS analysis. Proteins readily adsorb to the polypropylene (PP) C-CP fibers while buffer species are easily washed off the tips using DI-H2O. Elution of the solutes is achieved with an aliquot of 50:50 ACN:H2O, which is compatible with the subsequent spotting on the MALDI target with the matrix solution. Lysozyme and cytochrome c are used as test species, with a primary buffer composition of 100 mM Tris-HCl. In this case, direct MALDI-MS produces no discernible protein signals. SPE on the C-CP fibers yields high fidelity mass spectra for 1 μL sample volumes. Limits of detection for cytochrome c in 100 mM Tris-HCl are on the order of 40 nM. Extraction of cytochrome c from buffer concentrations of up to 1 M Tris-HCl, provides signal recoveries that are suppressed by only ~50 % versus neat protein solutions. Finally, extraction of 3.1 μM cytochrome c from a synthetic urine matrix exhibits excellent recovery.

  14. Can an aquatic macrophyte bioaccumulate glyphosate? A watershed scale study using a non-target hydrophyte Ludwigia peploides

    NASA Astrophysics Data System (ADS)

    Perez, Debora; Okada, Elena; Menone, Mirta; Aparicio, Virginia; Costa, Jose Luis

    2017-04-01

    The hydrophyte Ludwigia peploides is widely distributed in South America streams, and therefore, it can be used as a biomonitor for pesticides used in agricultural production. Glyphosate is one of the main pesticides used in Argentina. This has resulted in its occurrence in non-target wetland ecosystems. The objectives of this study were to: 1) establish and validate an extraction and quantification methodology for glyphosate in L.peploides plants, and 2) evaluated the role of this species as a glyphosate biomonitor in the agricultural watershed of the El Crespo stream. For the first objective, we collected plant material in the field. The leaves were dissected and oven dried at 60° C, grinded and sieved through a 0.5 mm mesh. Different solutions were tested for the extraction step. Labeled glyphosate was used as an internal standard to evaluate the recovery rate and the matrix effect of the different extraction methods. Glyphosate was derivatized with FMOC-Cl and then quantified by ultra-performance liquid chromatography (UPLC) coupled to a mass tandem spectrometer (MS/MS). The method based on an aqueous phase extraction step 0.01 mg/mL of activated carbon as a clean-up to decrease the matrix interference had a recovery of 117 ± 20% and the matrix effect was less than 20%. This method was used to analyze the glyphosate levels in L.peploides in the El Crespo stream. For the second objective, plants of L.peploides were collected on March 2016 in eight monitoring sites of the stream from the headwaters to the stream mouth. Surface water and sediments samples were collected at the same time to calculate the bioconcentration factors (BCFs) and biota-sediment bioaccumulation factors (BSAFs). The BCFs ranged between 28.57 - 280 L/Kg and the BSAFs ranged between 2.52- 30.66 at different sites. These results indicate that L.peploides can bioaccumulated glyphosate in its leaves and the major bioavailability is given mainly by the herbicide molecules present in surface water, rather than sediment. In this sense, L.peploides could be used as biomonitor organism to evaluate a glyphosate levels in the freshwater aquatic ecosystems

  15. Studies of mechanisms of decay and recovery in organic dye-doped polymers using spatially resolved white light interferometry

    NASA Astrophysics Data System (ADS)

    Anderson, Benjamin; Bernhardt, Elizabeth; Kuzyk, Mark

    2012-10-01

    Several organic dyes have been shown to self heal when doped in a polymer matrix. Most measurements to date use optical absorbance, amplified spontaneous emission, or digital imaging as a probe. Each method determines a subset of the relevant parameters. We have constructed a white light interferometric microscope, which measures the absorption spectrum and change in refractive index during decay and recovery simultaneously at multiple points in the material. We report on preliminary measurements and results concerning the microscopes spatial resolution.

  16. Interlaboratory comparison of extraction efficiency of pesticides from surface and laboratory water using solid-phase extraction disks.

    PubMed

    Senseman, Scott A; Mueller, Thomas C; Riley, Melissa B; Wauchope, R Don; Clegg, Chris; Young, Roddy W; Southwick, Lloyd M; Moye, H Anson; Dumas, Jose A; Mersie, Wondi; Mattice, John D; Leidy, Ross B

    2003-06-18

    A continuation of an earlier interlaboratory comparison was conducted (1) to assess solid-phase extraction (SPE) using Empore disks to extract atrazine, bromacil, metolachlor, and chlorpyrifos from various water sources accompanied by different sample shipping and quantitative techniques and (2) to compare quantitative results of individual laboratories with results of one common laboratory. Three replicates of a composite surface water (SW) sample were fortified with the analytes along with three replicates of deionized water (DW). A nonfortified DW sample and a nonfortified SW sample were also extracted. All samples were extracted using Empore C(18) disks. After extraction, part of the samples were eluted and analyzed in-house. Duplicate samples were evaporated in a 2-mL vial, shipped dry to a central laboratory (SDC), redissolved, and analyzed. Overall, samples analyzed in-house had higher recoveries than SDC samples. Laboratory x analysis type and laboratory x water source interactions were significant for all four compounds. Seven laboratories participated in this interlaboratory comparison program. No differences in atrazine recoveries were observed from in-house samples analyzed by laboratories A, B, D, and G compared with the recovery of SDC samples. In-house atrazine recoveries from laboratories C and F were higher when compared with recovery from SDC samples. However, laboratory E had lower recoveries from in-house samples compared with SDC samples. For each laboratory, lower recoveries were observed for chlorpyrifos from the SDC samples compared with samples analyzed in-house. Bromacil recovery was <65% at two of the seven laboratories in the study. Bromacil recoveries for the remaining laboratories were >75%. Three laboratories showed no differences in metolachlor recovery; two laboratories had higher recoveries for samples analyzed in-house, and two other laboratories showed higher metolachlor recovery for SDC samples. Laboratory G had a higher recovery in SW for all four compounds compared with DW. Other laboratories that had significant differences in pesticide recovery between the two water sources showed higher recovery in DW than in the SW regardless of the compound. In comparison to earlier work, recovery of these compounds using SPE disks as a temporary storage matrix may be more effective than shipping dried samples in a vial. Problems with analytes such as chlorpyrifos are unavoidable, and it should not be assumed that an extraction procedure using SPE disks will be adequate for all compounds and transferrable across all chromatographic conditions.

  17. Dose-Dependent Differential Effect of Neurotrophic Factors on In Vitro and In Vivo Regeneration of Motor and Sensory Neurons

    PubMed Central

    Santos, Daniel; Gonzalez-Perez, Francisco; Navarro, Xavier

    2016-01-01

    Although peripheral axons can regenerate after nerve transection and repair, functional recovery is usually poor due to inaccurate reinnervation. Neurotrophic factors promote directional guidance to regenerating axons and their selective application may help to improve functional recovery. Hence, we have characterized in organotypic cultures of spinal cord and dorsal root ganglia the effect of GDNF, FGF-2, NGF, NT-3, and BDNF at different concentrations on motor and sensory neurite outgrowth. In vitro results show that GDNF and FGF-2 enhanced both motor and sensory neurite outgrowth, NGF and NT-3 were the most selective to enhance sensory neurite outgrowth, and high doses of BDNF selectively enhanced motor neurite outgrowth. Then, NGF, NT-3, and BDNF (as the most selective factors) were delivered in a collagen matrix within a silicone tube to repair the severed sciatic nerve of rats. Quantification of Fluorogold retrolabeled neurons showed that NGF and NT-3 did not show preferential effect on sensory regeneration whereas BDNF preferentially promoted motor axons regeneration. Therefore, the selective effects of NGF and NT-3 shown in vitro are lost when they are applied in vivo, but a high dose of BDNF is able to selectively enhance motor neuron regeneration both in vitro and in vivo. PMID:27867665

  18. Effect of grazing on vegetation and soil of the heuweltjieveld in the Succulent Karoo, South Africa

    NASA Astrophysics Data System (ADS)

    Schmiedel, Ute; Röwer, Inga Ute; Luther-Mosebach, Jona; Dengler, Jürgen; Oldeland, Jens; Gröngröft, Alexander

    2016-11-01

    We asked how historical and recent grazing intensity affect the patchy landscape of the heuweltjieveld in the semi-arid biodiversity hotspot Succulent Karoo. The study was carried out on a communal farmland 80 km south-west of Springbok, in Namaqualand. Heuweltjies are roughly circular earth mounds that are regularly distributed in this landscape. We sampled plant species and life-form composition, diversity measures, habitat and soil variables in 100 m2 plots, placed in three visually distinguishable heuweltjie zones (centre, fringe, and matrix) and distributed across grazing camps with different recent and historic grazing intensities. Differences between heuweltjie zones were assessed with ANOVAs and multiple linear regressions. The effect of past and recent grazing intensity on soil and plant variables was analysed by Generalized Linear Models for each heuweltjie zone separately. The three zones constituted clearly distinguishable units in terms of vegetation and soil characteristics. Soil pH and cover of annual plants increased from matrix to centres, while total vegetation cover, species richness and perennial plant cover decreased in the same direction. Historic (pre-2000) grazing patterns had the strongest effects on fringes, showing the strongest soil and vegetation-related signs of overutilization with increased stocking density. Centres showed signs of overutilization irrespective of the stocking density. The much shorter exposure to recent grazing pattern (post-2000), which was nearly inverse to the historic grazing pattern, showed increase of vegetation cover (centres) and species richness (matrix) with recent grazing intensity. We interpret these effects as still visible responses of the lower grazing intensity in these camps during the historic period. No recovery under recent grazing was observed at any of the zones. We conclude that irrespective of their conducive growing conditions, once transformed to a disturbed state, heuweltjie centres recover slowly, whereas the less impacted soil and vegetation of fringes are more responsive than centres and matrix.

  19. Determination of perfluorinated alkyl acids in corn, popcorn and popcorn bags before and after cooking by focused ultrasound solid-liquid extraction, liquid chromatography and quadrupole-time of flight mass spectrometry.

    PubMed

    Moreta, Cristina; Tena, María Teresa

    2014-08-15

    An analytical method is proposed to determine ten perfluorinated alkyl acids (PFAAs) [nine perfluorocarboxylic acids (PFCAs) and perfluorooctane sulfonate (PFOS)] in corn, popcorn and microwave popcorn packaging by focused ultrasound solid-liquid extraction (FUSLE) and ultra high performance liquid chromatography (UHPLC) coupled to quadrupole-time of flight mass spectrometry (QTOF-MS/MS). Selected PFAAs were extracted efficiently in only one 10-s cycle by FUSLE, a simple, safe and inexpensive technique. The developed method was validated for microwave popcorn bags matrix as well as corn and popcorn matrices in terms of linearity, matrix effect error, detection and quantification limits, repeatability and recovery values. The method showed good accuracy with recovery values around 100% except for the lowest chain length PFAAs, satisfactory reproducibility with RSDs under 16%, and sensitivity with limits of detection in the order of hundreds picograms per gram of sample (between 0.2 and 0.7ng/g). This method was also applied to the analysis of six microwave popcorn bags and the popcorn inside before and after cooking. PFCAs contents between 3.50ng/g and 750ng/g were found in bags, being PFHxA (perfluorohexanoic acid) the most abundant of them. However, no PFAAs were detected either corn or popcorn, therefore no migration was assumed. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Behavioural improvement in a minimally conscious state after caloric vestibular stimulation: evidence from two single case studies.

    PubMed

    Vanzan, Serena; Wilkinson, David; Ferguson, Heather; Pullicino, Patrick; Sakel, Mohamed

    2017-04-01

    To investigate whether caloric vestibular stimulation, a non-invasive form of neuro-modulation, alters the level of awareness in people residing in a minimally conscious state. Single-case ( n = 2), prospective, controlled (ABAB) efficacy study. Tertiary, neuro-rehabilitation inpatient ward within a university hospital. Two individuals in a minimally conscious state. Left ear caloric vestibular stimulation was performed in two four/five-week blocks interleaved with two four/five-week blocks of sham stimulation. Session duration and frequency gradually increased within each block from once per day for 10 minutes (Week 1) to once per day for 20 minutes (Week 2) to 20 minutes twice per day in the remaining weeks. Wessex Head Injury Matrix, JFK Coma Recovery Scale - Revised. Both participants' Wessex Head Injury Matrix scores indicated a transition from involuntary (i.e. mechanical vocalization) to voluntary (i.e. gesture making, selective responses to family members) behaviour that was time-locked to the onset of active stimulation. In one participant, this improvement persisted for at least four weeks after active stimulation, while in the other it diminished two weeks after stimulation. Allied, although less dramatic, changes were seen on the arousal and auditory subscales of the JFK Coma Recovery Scale - Revised. The data provide the first evidence that vestibular stimulation may help improve outcome in a low awareness state, although further studies are needed to replicate effect and determine longer-term benefit.

  1. Ammonia gas sensing behavior of tanninsulfonic acid doped polyaniline-TiO₂ composite.

    PubMed

    Bairi, Venu Gopal; Bourdo, Shawn E; Sacre, Nicolas; Nair, Dev; Berry, Brian C; Biris, Alexandru S; Viswanathan, Tito

    2015-10-16

    A highly active tannin doped polyaniline-TiO₂ composite ammonia gas sensor was developed and the mechanism behind the gas sensing activity was reported for the first time. A tanninsulfonic acid doped polyaniline (TANIPANI)-titanium dioxide nanocomposite was synthesized by an in situ polymerization of aniline in the presence of tanninsulfonic acid and titanium dioxide nanoparticles. X-ray diffraction and thermogravimetric analysis were utilized to determine the incorporation of TiO₂ in TANIPANI matrix. UV-Visible and infrared spectroscopy studies provided information about the electronic interactions among tannin, polyaniline, and TiO₂. Scanning electron microscopy (SEM) along with energy dispersive X-ray spectroscopy (EDS) and atomic force microscopy (AFM) surface analysis techniques were used to investigate the metal oxide dispersions inside polyaniline matrix. Gas sensors were prepared by spin coating solutions of TANIPANI-TiO₂ and TANIPANI composites onto glass slides. Sensors were tested at three different concentrations (20 ppm, 40 ppm, and 60 ppm) of ammonia gas at ambient temperature conditions by measuring the changes in surface resistivity of the films with respect to time. Ammonia gas sensing plots are presented showing the response values, response times and recovery times. The TANIPANI-TiO₂ composite exhibited better response and shorter recovery times when compared to TANIPANI control and other polyaniline composites that have been reported in the literature. For the first time a proposed mechanism of gas sensing basing on the polaron band localization and its effects on the gas sensing behavior of polyaniline are reported.

  2. Biomimetic hydrogels direct spinal progenitor cell differentiation and promote functional recovery after spinal cord injury.

    PubMed

    Geissler, Sydney A; Sabin, Alexandra L; Besser, Rachel R; Gooden, Olivia M; Shirk, Bryce D; Nguyen, Quan M; Khaing, Zin Z; Schmidt, Christine E

    2018-04-01

    Demyelination that results from disease or traumatic injury, such as spinal cord injury (SCI), can have a devastating effect on neural function and recovery. Many researchers are examining treatments to minimize demyelination by improving oligodendrocyte availability in vivo. Transplantation of stem and oligodendrocyte progenitor cells is a promising option, however, trials are plagued by undirected differentiation. Here we introduce a biomaterial that has been optimized to direct the differentiation of neural progenitor cells (NPCs) toward oligodendrocytes as a cell delivery vehicle after SCI. A collagen-based hydrogel was modified to mimic the mechanical properties of the neonatal spinal cord, and components present in the developing extracellular matrix were included to provide appropriate chemical cues to the NPCs to direct their differentiation toward oligodendrocytes. The hydrogel with cells was then transplanted into a unilateral cervical contusion model of SCI to examine the functional recovery with this treatment. Six behavioral tests and histological assessment were performed to examine the in vivo response to this treatment. Our results demonstrate that we can achieve a significant increase in oligodendrocyte differentiation of NPCs compared to standard culture conditions using a three-component biomaterial composed of collagen, hyaluronic acid, and laminin that has mechanical properties matched to those of neonatal neural tissue. Additionally, SCI rats with hydrogel transplants, with and without NPCs, showed functional recovery. Animals transplanted with hydrogels with NPCs showed significantly increased functional recovery over six weeks compared to the media control group. The three-component hydrogel presented here has the potential to provide cues to direct differentiation in vivo to encourage regeneration of the central nervous system.

  3. Multidimensional Compressed Sensing MRI Using Tensor Decomposition-Based Sparsifying Transform

    PubMed Central

    Yu, Yeyang; Jin, Jin; Liu, Feng; Crozier, Stuart

    2014-01-01

    Compressed Sensing (CS) has been applied in dynamic Magnetic Resonance Imaging (MRI) to accelerate the data acquisition without noticeably degrading the spatial-temporal resolution. A suitable sparsity basis is one of the key components to successful CS applications. Conventionally, a multidimensional dataset in dynamic MRI is treated as a series of two-dimensional matrices, and then various matrix/vector transforms are used to explore the image sparsity. Traditional methods typically sparsify the spatial and temporal information independently. In this work, we propose a novel concept of tensor sparsity for the application of CS in dynamic MRI, and present the Higher-order Singular Value Decomposition (HOSVD) as a practical example. Applications presented in the three- and four-dimensional MRI data demonstrate that HOSVD simultaneously exploited the correlations within spatial and temporal dimensions. Validations based on cardiac datasets indicate that the proposed method achieved comparable reconstruction accuracy with the low-rank matrix recovery methods and, outperformed the conventional sparse recovery methods. PMID:24901331

  4. On-matrix derivatization extraction of chemical weapons convention relevant alcohols from soil.

    PubMed

    Chinthakindi, Sridhar; Purohit, Ajay; Singh, Varoon; Dubey, D K; Pardasani, Deepak

    2013-10-11

    Present study deals with the on-matrix derivatization-extraction of aminoalcohols and thiodiglycols, which are important precursors and/or degradation products of VX analogues and vesicants class of chemical warfare agents (CWAs). The method involved hexamethyldisilazane (HMDS) mediated in situ silylation of analytes on the soil. Subsequent extraction and gas chromatography-mass spectrometry analysis of derivatized analytes offered better recoveries in comparison to the procedure recommended by the Organization for the Prohibition of Chemical Weapons (OPCW). Various experimental conditions such as extraction solvent, reagent and catalyst amount, reaction time and temperature were optimized. Best recoveries of analytes ranging from 45% to 103% were obtained with DCM solvent containing 5%, v/v HMDS and 0.01%, w/v iodine as catalyst. The limits of detection (LOD) and limit of quantification (LOQ) with selected analytes ranged from 8 to 277 and 21 to 665ngmL(-1), respectively, in selected ion monitoring mode. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. A modified lead-matrix separation procedure shown for lead isotope analysis in Trojan silver artefacts as an example.

    PubMed

    Vogl, Jochen; Paz, Boaz; Koenig, Maren; Pritzkow, Wolfgang

    2013-03-01

    A modified Pb-matrix separation procedure using NH4HCO3 solution as eluent has been developed and validated for determination of Pb isotope amount ratios by thermal ionization mass spectrometry. The procedure is based on chromatographic separation using the Pb·Spec resin and an in-house-prepared NH4HCO3 solution serving as eluent. The advantages of this eluent are low Pb blanks (<40 pg mL(-1)) and the property that NH4HCO3 can be easily removed by use of a heating step (>60 °C). Pb recovery is >95 % for water samples. For archaeological silver samples, however, the Pb recovery is reduced to approximately 50 %, but causes no bias in the determination of Pb isotope amount ratios. The validated procedure was used to determine lead isotope amount ratios in Trojan silver artefacts with expanded uncertainties (k = 2) <0.09 %.

  6. Application of molecularly imprinted polymer based matrix solid phase dispersion for determination of fluoroquinolones, tetracyclines and sulfonamides in meat.

    PubMed

    Wang, Geng Nan; Zhang, Lei; Song, Yi Ping; Liu, Ju Xiang; Wang, Jian Ping

    2017-10-15

    In this study, a type of novel mixed-template molecularly imprinted polymer was synthesized that was able to recognize 8 fluoroquinolones, 8 sulfonamides and 4 tetracyclines simultaneously with recoveries higher than 92%. Then the polymer was used to develop a matrix solid phase dispersion method for simultaneous extraction of the 20 drugs in pork followed by determination with ultra performance liquid chromatography. During the experiments, the MMIP amount, washing solvent and elution solvent were optimized respectively. The limits of detection of this method for the 20 drugs in pork were in the range of 0.5-3.0ngg -1 , and the intra-day and inter-day recoveries from the fortified blank samples were in the range of 74.5%-102.7%. Therefore, this method could be used as a rapid, simple, specific and sensitive method for multi-determination of the residues of the three classes of drugs in meat. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Simultaneous Separation of Actinium and Radium Isotopes from a Proton Irradiated Thorium Matrix

    DOE PAGES

    Mastren, Tara; Radchenko, Valery; Owens, Allison; ...

    2017-08-15

    A new method has been developed for the isolation of 223,224,225Ra, in high yield and purity, from a proton irradiated 232Th matrix. We report an all-aqueous process using multiple solid-supported adsorption steps including a citrate chelation method developed to remove >99.9% of the barium contaminants by activity from the final radium product. Moreover, we developed a procedure involving the use of three columns in succession, and the separation of 223,224,225Ra from the thorium matrix was obtained with an overall recovery yield of 91 ± 3%, average radiochemical purity of 99.9%, and production yields that correspond to physical yields based onmore » previously measured excitation functions.« less

  8. [Determination of trace gallium by graphite furnace atomic absorption spectrometry in urine].

    PubMed

    Zhou, L Z; Fu, S; Gao, S Q; He, G W

    2016-06-20

    To establish a method for determination trace gallium in urine by graphite furnace atomic absorption spectrometry (GFAAS). The ammonium dihydrogen phosphate was matrix modifier. The temperature effect about pyrolysis (Tpyr) and atomization temperature were optimized for determination of trace gallium. The method of technical standard about within-run, between-run and recoveries of standard were optimized. The method showed a linear relationship within the range of 0.20~80.00 μg/L (r=0.998). The within-run and between-run relative standard deviations (RSD) of repetitive measurement at 5.0, 10.0, 20.0 μg/L concentration levels were 2.1%~5.5% and 2.3%~3.0%. The detection limit was 0.06 μg/L. The recoveries of gallium were 98.2%~101.1%. This method is simple, low detection limit, accurate, reliable and reproducible. It has been applied for determination of trace gallium in urine samples those who need occupation health examination or poisoning diagnosis.

  9. Effects of Exopolysaccharide Production on Liquid Vegetative Growth, Stress Survival and Stationary Phase Recovery in Myxococcus xanthus

    PubMed Central

    Hu, Wei; Wang, Jing; McHardy, Ian; Lux, Renate; Yang, Zhe; Li, Yuezhong; Shi, Wenyuan

    2013-01-01

    Exopolysaccharide (EPS) of Myxococcus xanthus is a well-regulated cell surface component. In addition to its known functions for social motility and fruiting body formation on solid surfaces, EPS has also been proposed to play a role in multi-cellular clumping in liquid medium, though this phenomenon has not been well studied. In this report, we confirmed that M. xanthus clumps formed in liquid were correlated with EPS levels and demonstrated that the EPS encased cell clumps exhibited biofilm-like structures. The clumps protected the cells at physiologically relevant EPS concentrations, while cells lacking EPS exhibited significant reduction in long-term viability and resistance to stressful conditions. However, excess EPS production was counterproductive to vegetative growth and viable cell recovery declined in extended late stationary phase as cells became trapped in the matrix of clumps. Therefore, optimal EPS production by M. xanthus is important for normal physiological functions in liquid. PMID:22538652

  10. Validation of quantitative method for azoxystrobin residues in green beans and peas.

    PubMed

    Abdelraheem, Ehab M H; Hassan, Sayed M; Arief, Mohamed M H; Mohammad, Somaia G

    2015-09-01

    This study presents a method validation for extraction and quantitative analysis of azoxystrobin residues in green beans and peas using HPLC-UV and the results confirmed by GC-MS. The employed method involved initial extraction with acetonitrile after the addition of salts (magnesium sulfate and sodium chloride), followed by a cleanup step by activated neutral carbon. Validation parameters; linearity, matrix effect, LOQ, specificity, trueness and repeatability precision were attained. The spiking levels for the trueness and the precision experiments were (0.1, 0.5, 3 mg/kg). For HPLC-UV analysis, mean recoveries ranged between 83.69% to 91.58% and 81.99% to 107.85% for green beans and peas, respectively. For GC-MS analysis, mean recoveries ranged from 76.29% to 94.56% and 80.77% to 100.91% for green beans and peas, respectively. According to these results, the method has been proven to be efficient for extraction and determination of azoxystrobin residues in green beans and peas. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Determination of Fosetyl and Phosphonic Acid at 0.010 mg/kg Level by Ion Chromatography Tandem Mass Spectrometry.

    PubMed

    Bauer, Anna; Luetjohann, Jens; Rohn, Sascha; Kuballa, Juergen; Jantzen, Eckard

    2018-01-10

    A new sensitive, fast, and robust method using ion chromatography tandem mass spectrometry (IC-MS/MS) for the determination of fosetyl and phosphonic acid in plant-derived matrices was developed. For compensation of matrix effects and differences in recovery rates the isotopically labeled internal standard (ILIS) 18 O 3 -labeled phosphonic acid was added to the samples prior to the extraction of the target compounds. The validation of the method for the matrices tomato, apple, lemon, sultana, avocado, and wheat was performed according to the actual EU guidance document SANTE/11945/2015. The precision and accuracy were determined in five replicates at spiking levels of 0.010 and 0.100 mg/kg with recovery rates between 76 and 105% and RSDs between 1.2 and 17.8%. In this paper, it was achieved for the first time to detect both fosetyl and phosphonic acid at the reporting level of 0.010 mg/kg most relevant for organic plant food commodities.

  12. Organogelator-Cellulose Composite for Practical and Eco-Friendly Marine Oil-Spill Recovery.

    PubMed

    Prathap, Annamalai; Sureshan, Kana M

    2017-08-01

    Marine oil spills pose serious threats to the ecosystem and economy. There is much interest in developing sorbents that can tackle such spills. We have developed a novel sorbent by impregnating cellulose pulp with a sugar-derived oleogelator, 1,2:5,6-di-O-cyclohexylidene-mannitol. The gelator molecules mask the surface-exposed hydroxyl groups of cellulose fibrils by engaging them in H-bonding and expose their hydrophobic parts making the fibers temporarily hydrophobic (water contact angle 110°). This sorbent absorbs oil effectively, selectively and instantly from oil-water mixtures due to its hydrophobicity. Then the gelator molecules get released uniformly in the oil and later self-assemble to fibers, as evident from SEM analysis, congealing the oil within the matrix. This hierarchical entrapment of the oil by non-covalent polymeric fibers within a covalent polymer matrix makes the gel very strong (230-fold increase in the yield stress) and rigid, making it suitable for practical use. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Validated LC–MS-MS Method for Multiresidual Analysis of 13 Illicit Phenethylamines in Amniotic Fluid

    PubMed Central

    Burrai, Lucia; Nieddu, Maria; Carta, Antonio; Trignano, Claudia; Sanna, Raimonda; Boatto, Gianpiero

    2016-01-01

    A multi-residue analytical method was developed for the determination in amniotic fluid (AF) of 13 illicit phenethylamines, including 12 compounds never investigated in this matrix before. Samples were subject to solid-phase extraction using; hydrophilic–lipophilic balance cartridges which gave good recoveries and low matrix effects on analysis of the extracts. The quantification was performed by liquid chromatography electrospray tandem mass spectrometry. The water–acetonitrile mobile phase containing 0.1% formic acid, used with a C18 reversed phase column, provided adequate separation, resolution and signal-to-noise ratio for the analytes and the internal standard. The final optimized method was validated according to international guidelines. A monitoring campaign to assess fetal exposure to these 13 substances of abuse has been performed on AF test samples obtained from pregnant women. All mothers (n = 194) reported no use of drugs of abuse during pregnancy, and this was confirmed by the analytical data. PMID:26755540

  14. Silk-based blood stabilization for diagnostics.

    PubMed

    Kluge, Jonathan A; Li, Adrian B; Kahn, Brooke T; Michaud, Dominique S; Omenetto, Fiorenzo G; Kaplan, David L

    2016-05-24

    Advanced personalized medical diagnostics depend on the availability of high-quality biological samples. These are typically biofluids, such as blood, saliva, or urine; and their collection and storage is critical to obtain reliable results. Without proper temperature regulation, protein biomarkers in particular can degrade rapidly in blood samples, an effect that ultimately compromises the quality and reliability of laboratory tests. Here, we present the use of silk fibroin as a solid matrix to encapsulate blood analytes, protecting them from thermally induced damage that could be encountered during nonrefrigerated transportation or freeze-thaw cycles. Blood samples are recovered by simple dissolution of the silk matrix in water. This process is demonstrated to be compatible with a number of immunoassays and provides enhanced sample preservation in comparison with traditional air-drying paper approaches. Additional processing can remediate interactions with conformational structures of the silk protein to further enhance blood stabilization and recovery. This approach can provide expanded utility for remote collection of blood and other biospecimens empowering new modalities of temperature-independent remote diagnostics.

  15. Experiment K-7-29: Connective Tissue Studies. Part 2; Changes in Muscle Serine Proteases, Serpins and Matrix Molecules

    NASA Technical Reports Server (NTRS)

    Festoff, B. W.; Ilyina-Kakueva, E. I.; Rayford, A. R.; Burkovskaya, T. E.; Reddy, B. R.; Rao, J. S.

    1994-01-01

    In zero or micro-gravity, type 1 muscle fibers atrophy and lose predominance, especially in slow-twitch muscles. No increase in mononuclear cells has been observed, just as in simple denervation, where both types 1 and 2 fibers atrophy, again without infiltration of cells, but with clear satellite cell proliferation. However, extracellular matrix (ECM) degradation takes place after denervation and if re-innervation is encouraged, functional recovery to near control levels may be achieved. No information is available concerning the ECM milieu, the activation of serine proteases, their efficacy in degrading ECM components and the production of locally-derived natural protease inhibitors (serpins) in effecting surface proteolytic control. In addition, no studies are available concerning the activation of these enzymes in micro- or zero gravity or their response to muscle injury on the ground and what alterations, if any, occur in space. These studies were the basis for the experiments in Cosmos 2044.

  16. Characterization and quantitation of polyolefin microplastics in personal-care products using high-temperature gel-permeation chromatography.

    PubMed

    Hintersteiner, Ingrid; Himmelsbach, Markus; Buchberger, Wolfgang W

    2015-02-01

    In recent years, the development of reliable methods for the quantitation of microplastics in different samples, including evaluating the particles' adverse effects in the marine environment, has become a great concern. Because polyolefins are the most prevalent type of polymer in personal-care products containing microplastics, this study presents a novel approach for their quantitation. The method is suitable for aqueous and hydrocarbon-based products, and includes a rapid sample clean-up involving twofold density separation and a subsequent quantitation with high-temperature gel-permeation chromatography. In contrast with previous procedures, both errors caused by weighing after insufficient separation of plastics and matrix and time-consuming visual sorting are avoided. In addition to reliable quantitative results, in this investigation a comprehensive characterization of the polymer particles isolated from the product matrix, covering size, shape, molecular weight distribution and stabilization, is provided. Results for seven different personal-care products are presented. Recoveries of this method were in the range of 92-96 %.

  17. A new method of analysis of peroxydisulfate using ion chromatography and its application to the simultaneous determination of peroxydisulfate and other common inorganic ions in a peroxydisulfate matrix.

    PubMed

    Khan, Nymul E; Adewuyi, Yusuf G

    2011-01-21

    A new method for the determination of peroxydisulfate using ion chromatography has been developed. Elution of peroxydisulfate was effected by isocratic elution using 200 mM NaOH at 40°C. A modification of the method using gradient elution was able to simultaneously determine other common inorganic ions (nitrate, nitrite, sulfate and chloride) down to significantly low concentrations in a peroxydisulfate matrix. The relative standard deviations (RSD) were in the range of 0.5-5%, for peak areas and <0.2% for peak retention times. The recoveries were between 95% and 120% for a concentration range of about 0.5-42 ppm. The limit of detection for peroxydisulfate ion was 0.2 ppm and for the other ions were ≤2×10(-2) ppm. The calibration curves were linear with slope and intercepts close to 1 and 0, respectively. Copyright © 2010 Elsevier B.V. All rights reserved.

  18. Multi-residue analysis of pharmaceuticals in aqueous environmental samples by online solid-phase extraction-ultra-high-performance liquid chromatography-tandem mass spectrometry: optimisation and matrix effects reduction by quick, easy, cheap, effective, rugged and safe extraction.

    PubMed

    Bourdat-Deschamps, Marjolaine; Leang, Sokha; Bernet, Nathalie; Daudin, Jean-Jacques; Nélieu, Sylvie

    2014-07-04

    The aim of this study was to develop and optimise an analytical method for the quantification of a bactericide and 13 pharmaceutical products, including 8 antibiotics (fluoroquinolones, tetracyclines, sulfonamides, macrolide), in various aqueous environmental samples: soil water and aqueous fractions of pig slurry, digested pig slurry and sewage sludge. The analysis was performed by online solid-phase extraction coupled to ultra-high performance liquid chromatography with tandem mass spectrometry (online SPE-UHPLC-MS-MS). The main challenge was to minimize the matrix effects observed in mass spectrometry, mostly due to ion suppression. They depended on the dissolved organic carbon (DOC) content and its origin, and ranged between -22% and +20% and between -38% and -93% of the signal obtained without matrix, in soil water and slurry supernatant, respectively. The very variable levels of these matrix effects suggested DOC content cut-offs above which sample purification was required. These cut-offs depended on compounds, with concentrations ranging from 30 to 290mgC/L for antibiotics (except tylosine) up to 600-6400mgC/L for the most apolar compounds. A modified Quick, Easy, Cheap, Effective, Rugged and Safe (QuEChERS) extraction procedure was therefore optimised using an experimental design methodology, in order to purify samples with high DOC contents. Its performance led to a compromise, allowing fluoroquinolone and tetracycline analysis. The QuEChERS extraction salts consisted therefore of sodium acetate, sodium sulfate instead of magnesium sulfate, and sodium ethylenediaminetetraacetate (EDTA) as a ligand of divalent cations. The modified QuEChERS procedure employed for the extraction of pharmaceuticals in slurry and digested slurry liquid phases reduced the matrix effects for almost all the compounds, with extraction recoveries generally above 75%. The performance characteristics of the method were evaluated in terms of linearity, intra-day and inter-day precision, accuracy and limits of quantification, which reached concentration ranges of 5-270ng/L in soil water and sludge supernatant, and 31-2400ng/L in slurry and digested slurry supernatants, depending on the compounds. The new method was then successfully applied for the determination of the target compounds in environmental samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Visual analysis of immiscible displacement processes in porous media under ultrasound effect

    NASA Astrophysics Data System (ADS)

    Naderi, Khosrow; Babadagli, Tayfun

    2011-05-01

    The effect of sonic waves, in particular, ultrasonic radiation, on immiscible displacement in porous media and enhanced oil recovery has been of interest for more than five decades. Attempts were made to investigate the effect through core scale experimental or theoretical models. Visual experiments are useful to scrutinize the reason for improved oil recovery under acoustic waves of different frequency but are not abundant in literature. In this paper, we report observations and analyses as to the effects of ultrasonic energy on immiscible displacement and interaction of the fluid matrix visually in porous media through two-dimensional (2D) sand pack experiments. 2D glass bead models with different wettabilities were saturated with different viscosity oils and water was injected into the models. The experiments were conducted with and without ultrasound. Dynamic water injection experiments were preferred as they had both viscous and capillary forces in effect. The displacement patterns were evaluated both in terms of their shape, size, and the interface characteristics quantitatively and qualitatively to account for the effects of ultrasonic waves on the displacement and the reason for increased oil production under this type of sonic wave. More compact clusters were observed when ultrasonic energy was present in water-wet systems. In the oil-wet cases, more oil was produced after breakthrough when ultrasound was applied and no compact clusters were formed in contrast to the water-wet cases.

  20. Effects of glyphosate formulations on the population dynamics of two freshwater cladoceran species.

    PubMed

    Reno, U; Doyle, S R; Momo, F R; Regaldo, L; Gagneten, A M

    2018-02-05

    The general objective of this work is to experimentally assess the effects of acute glyphosate pollution on two freshwater cladoceran species (Daphnia magna and Ceriodaphnia dubia) and to use this information to predict the population dynamics and the potential for recovery of exposed organisms. Five to six concentrations of four formulations of glyphosate (4-Gly) (Eskoba ® , Panzer Gold ® , Roundup Ultramax ® and Sulfosato Touchdown ® ) were evaluated in both cladoceran species through acute tests and 15-day recovery tests in order to estimate the population dynamics of microcrustaceans. The endpoints of the recovery test were: survival, growth (number of molts), fecundity, and the intrinsic population growth rate (r). A matrix population model (MPM) was applied to r of the survivor individuals of the acute tests, followed by a Monte Carlo simulation study. Among the 4-Gly tested, Sulfosato Touchdown ® was the one that showed higher toxicity, and C. dubia was the most sensitive species. The Monte Carlo simulation study showed an average value of λ always <1 for D. magna, indicating that its populations would not be able to survive under natural environmental conditions after an acute Gly exposure between 0.25 and 35 a.e. mg L -1 . The average value of λ for C. dubia was also <1 after exposure to Roundup Ultramax ® : 1.30 and 1.20 for 1.21 and 2.5 mg a.e. L -1 ,respectively. The combined methodology-recovery tests and the later analysis through MPM with a Monte Carlo simulation study-is proposed to integrate key demographic parameters and predict the possible fate of microcrustacean populations after being exposed to acute 4-Gly contamination events.

  1. Subcontinuum mass transport of hydrocarbons in nanoporous media and long-time kinetics of recovery from unconventional reservoirs

    NASA Astrophysics Data System (ADS)

    Bocquet, Lyderic

    2015-11-01

    In this talk I will discuss the transport of hydrocarbons across nanoporous media and analyze how this transport impacts at larger scales the long-time kinetics of hydrocarbon recovery from unconventional reservoirs (the so-called shale gas). First I will establish, using molecular simulation and statistical mechanics, that the continuum description - the so-called Darcy law - fails to predict transport within a nanoscale organic matrix. The non-Darcy behavior arises from the strong adsorption of the alkanes in the nanoporous material and the breakdown of hydrodynamics at the nanoscale, which contradicts the assumption of viscous flow. Despite this complexity, all permeances collapse on a master curve with an unexpected dependence on alkane length, which can be described theoretically by a scaling law for the permeance. Then I will show that alkane recovery from such nanoporous reservoirs is dynamically retarded due to interfacial effects occuring at the material's interface. This occurs especially in the hydraulic fracking situation in which water is used to open fractures to reach the hydrocarbon reservoirs. Despite the pressure gradient used to trigger desorption, the alkanes remain trapped for long times until water desorbs from the external surface. The free energy barrier can be predicted in terms of an effective contact angle on the composite nanoporous surface. Using a statistical description of the alkane recovery, I will then demonstrate that this retarded dynamics leads to an overall slow - algebraic - decay of the hydrocarbon flux. Such a behavior is consistent with algebraic decays of shale gas flux from various wells reported in the literature. This work was performed in collaboration with B. Coasne, K. Falk, T. Lee, R. Pellenq and F. Ulm, at the UMI CNRS-MIT, Massachusetts Institute of Technology, Cambridge, USA.

  2. A Structurally and Functionally Biomimetic Biphasic Scaffold for Intervertebral Disc Tissue Engineering

    PubMed Central

    Choy, Andrew Tsz Hang; Chan, Barbara Pui

    2015-01-01

    Tissue engineering offers high hopes for the treatment of intervertebral disc (IVD) degeneration. Whereas scaffolds of the disc nucleus and annulus have been extensively studied, a truly biomimetic and mechanically functional biphasic scaffold using naturally occurring extracellular matrix is yet to be developed. Here, a biphasic scaffold was fabricated with collagen and glycosaminoglycans (GAGs), two of the most abundant extracellular matrix components in the IVD. Following fabrication, the scaffold was characterized and benchmarked against native disc. The biphasic scaffold was composed of a collagen-GAG co-precipitate making up the nucleus pulposus-like core, and this was encapsulated in multiple lamellae of photochemically crosslinked collagen membranes comprising the annulus fibrosus-like lamellae. On mechanical testing, the height of our engineered disc recovered by ~82-89% in an annulus-independent manner, when compared with the 99% recovery exhibited by native disc. The annulus-independent nature of disc height recovery suggests that the fluid replacement function of the engineered nucleus pulposus core might mimic this hitherto unique feature of native disc. Biphasic scaffolds comprised of 10 annulus fibrosus-like lamellae had the best overall mechanical performance among the various designs owing to their similarity to native disc in most aspects, including elastic compliance during creep and recovery, and viscous compliance during recovery. However, the dynamic mechanical performance (including dynamic stiffness and damping factor) of all the biphasic scaffolds was similar to that of the native discs. This study contributes to the rationalized design and development of a biomimetic and mechanically viable biphasic scaffold for IVD tissue engineering. PMID:26115332

  3. Exploring matrix effects and quantifying organic additives in hydraulic fracturing associated fluids using liquid chromatography electrospray ionization mass spectrometry.

    PubMed

    Nell, Marika; Helbling, Damian E

    2018-05-23

    Hydraulic fracturing (HF) operations utilize millions of gallons of water amended with chemical additives including biocides, corrosion inhibitors, and surfactants. Fluids injected into the subsurface return to the surface as wastewaters, which contain a complex mixture of additives, transformation products, and geogenic chemical constituents. Quantitative analytical methods are needed to evaluate wastewater disposal alternatives or to conduct adequate exposure assessments. However, our narrow understanding of how matrix effects change the ionization efficiency of target analytes limits the quantitative analysis of polar to semi-polar HF additives by means of liquid chromatography electrospray ionization mass spectrometry (LC-ESI-MS). To address this limitation, we explored the ways in which matrix chemistry influences the ionization of seventeen priority HF additives with a modified standard addition approach. We then used the data to quantify HF additives in HF-associated fluids. Our results demonstrate that HF additives generally exhibit suppressed ionization in HF-associated fluids, though HF additives that predominantly form sodiated adducts exhibit significantly enhanced ionization in produced water samples, which is largely the result of adduct shifting. In a preliminary screening, we identified glutaraldehyde and 2-butoxyethanol along with homologues of benzalkonium chloride (ADBAC), polyethylene glycol (PEG), and polypropylene glycol (PPG) in HF-associated fluids. We then used matrix recovery factors to provide the first quantitative measurements of individual homologues of ADBAC, PEG, and PPG in HF-associated fluids ranging from mg L-1 levels in hydraulic fracturing fluid to low μg L-1 levels in PW samples. Our approach is generalizable across sample types and shale formations and yields important data to evaluate wastewater disposal alternatives or implement exposure assessments.

  4. Evaluation of two fast and easy methods for pesticide residue analysis in fatty food matrixes.

    PubMed

    Lehotay, Steven J; Mastovská, Katerina; Yun, Seon Jong

    2005-01-01

    Two rapid methods of sample preparation and analysis of fatty foods (e.g., milk, eggs, and avocado) were evaluated and compared for 32 pesticide residues representing a wide range of physicochemical properties. One method, dubbed the quick, easy, cheap, effective, rugged, and safe (QuEChERS) method for pesticide residue analysis, entailed extraction of 15 g sample with 15 mL acetonitrile (MeCN) containing 1% acetic acid followed by addition of 6 g anhydrous magnesium sulfate and 1.5 g sodium acetate. After centrifugation, 1 mL of the buffered MeCN extract underwent a cleanup step (in a technique known as dispersive solid-phase extraction) using 50 mg each of C18 and primary secondary amine sorbents plus 150 mg MgSO4. The second method incorporated a form of matrix solid-phase dispersion (MSPD), in which 0.5 g sample plus 2 g C18 and 2 g anhydrous sodium sulfate was mixed in a mortar and pestle and added above a 2 g Florisil column on a vacuum manifold. Then, 5 x 2 mL MeCN was used to elute the pesticide analytes from the sample into a collection tube, and the extract was concentrated to 0.5 mL by evaporation. Extracts in both methods were analyzed concurrently by gas chromatography/mass spectrometry and liquid chromatography/tandem mass spectrometry. The recoveries of semi-polar and polar pesticides were typically 100% in both methods (except that basic pesticides, such as thiabendazole and imazalil, were not recovered in the MSPD method), but recovery of nonpolar pesticides decreased as fat content of the sample increased. This trend was more pronounced in the QuEChERS method, in which case the most lipophilic analyte tested, hexachlorobenzene, gave 27 +/- 1% recovery (n=6) in avocado (15% fat) with a<10 ng/g limit of quantitation.

  5. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory : determination of organophosphate pesticides in whole water by continuous liquid-liquid extraction and capillary-column gas chromatography with flame photometric detection

    USGS Publications Warehouse

    Jha, Virendra K.; Wydoski, Duane S.

    2003-01-01

    A method for the isolation of 20 parent organophosphate pesticides and 5 organophosphate pesticide degradates from natural-water samples is described. Compounds are extracted from water samples with methylene chloride using a continuous liquid-liquid extractor for 6 hours. The solvent is evaporated using heat and a flow of nitrogen to a volume of 1 milliliter and solvent exchanged to ethyl acetate. Extracted compounds are determined by capillary-column gas chromatography with flame photometric detection. Single-operator derived method detection limits in three water-matrix samples ranged from 0.003 to 0.009 microgram per liter. Method performance was validated by spiking all compounds in three different matrices at three different concentrations. Eight replicates were analyzed at each concentration in each matrix. Mean recoveries of most method compounds spiked in surface-water samples ranged from 54 to 137 percent and those in ground-water samples ranged from 40 to 109 percent for all pesticides. Recoveries in reagent-water samples ranged from 42 to 104 percent for all pesticides. The only exception was O-ethyl-O-methyl-S-propylphosphorothioate, which had variable recovery in all three matrices ranging from 27 to 79 percent. As a result, the detected concentration of O-ethyl-O-methyl-S-propylphosphorothioate in samples is reported in this method with an estimated remark code. Based on the performance issue, two more compounds, disulfoton and ethion monoxon, also will be reported in this method with an estimated remark code. Estimated-value compounds, which are ?E-coded? in the data base, do not meet the performance criteria for unqualified quantification, but are retained in the method because the compounds are important owing to high use or potential environmental effects and because analytical performance has been consistent and reproducible.

  6. Methods of Analysis - Determination of Pyrethroid Insecticides in Water and Sediment Using Gas Chromatography/Mass Spectrometry

    USGS Publications Warehouse

    Hladik, Michelle; Smalling, Kelly L.; Kuivila, Kathryn

    2009-01-01

    A method for the determination of 14 pyrethroid insecticides in environmental water and sediment samples is described. The method was developed by the U.S. Geological Survey in response to increasing concern over the effects of pyrethroids on aquatic organisms. The pyrethroids included in this method are ones that are applied to many agricultural and urban areas. Filtered water samples are extracted for pyrethroids using solid-phase extraction (SPE) with no additional cleanup steps. Sediment and soil samples are extracted using a microwave-assisted extraction system, and the pyrethroids of interest are separated from co-extracted matrix interferences by passing the extracts through stacked graphitized carbon and alumina SPE cartridges, along with the use of high-performance liquid chromatography and gel-permeation chromatography (HPLC/GPC). Quantification of the pyrethroids from the extracted water and sediment samples is done using gas chromatography with mass spectrometry (GC/MS) or gas chromatography with tandem mass spectrometry (GC/MS/MS). Recoveries in test water samples fortified at 10 ng/L ranged from 83 to 107 percent, and recoveries in test sediment samples fortified at 10 ug/kg ranged from 82 to 101 percent; relative standard deviations ranged from 5 to 9 percent in the water samples and 3 to 9 percent in the sediment samples. Method detection limits (MDLs), calculated using U.S. Environmental Protection Agency procedures (40 CFR 136, Appendix B), in water ranged from 2.0 to 6.0 ng/L using GC/MS and 0.5 to 1.0 ng/L using GC/MS/MS. For sediment, the MDLs ranged from 1.0 to 2.6 ug/kg dry weight using GC/MS and 0.2 to 0.5 ug/kg dry weight using GC/MS/MS. The matrix-spike recoveries for each compound, when averaged for 12 environmental water samples, ranged from 84 to 96 percent, and when averaged for 27 environmental sediment samples, ranged from 88 to 100 percent.

  7. Epidural spinal cord compression with neurologic deficit associated with intrapedicular application of hemostatic gelatin matrix during pedicle screw insertion.

    PubMed

    Buchowski, Jacob M; Bridwell, Keith H; Lenke, Lawrence G; Good, Christopher R

    2009-06-01

    Case report. In order to demonstrate the dangers of intrapedicular application of a hemostatic gelatin matrix to decrease blood loss during pedicle screw insertion, we present 2 patients who--as a result of inadvertent extravasation of the matrix into the spinal canal--developed epidural spinal cord compression (ESCC) requiring emergent decompression. Variety of hemostatic agents can control bleeding during pedicle screw insertion. We have often used a hemostatic gelatin matrix to decrease bleeding from cannulated pedicles by injecting the material into the pedicle after manually palpating the pedicle. Medical records and radiographic studies of 2 patients with AIS who underwent surgical treatment of their deformity and developed a neurologic deficit due to extravasation of FloSeal were reviewed. A 15 year-old male underwent T4 to L2 posterior spinal fusion (PSF). During pedicle screw insertion, a change in NMEPs and SSEPs was noted. A wake-up test confirmed bilateral LE paraplegia. Screws were removed and no perforations were noted on manual palpation. MRI showed T7 to T10 ESCC. He underwent a T5 to T10 laminectomy and hemostatic gelatin matrix noted in the canal and was evacuated. He was ambulatory at 2 weeks and by 3 months he had complete recovery. The second patient was a 15 year-old female who underwent T4 to L1 PSF. Following screw insertion, deterioration in NMEPs and SSEPs was noted. Screws were removed and SCM data returned to baseline. Except for 3 screws that had an inferior breach (Left T7 and Bilateral T8), screws were reinserted and remainder of the surgery was uneventful. Postoperative examination was normal initially but 2 days later, she developed left LE numbness/weakness. Implants were removed and MRI showed T4 to T9 ESCC.She underwent a left (concave) T4 to T9 hemilaminectomy. Hemostatic gelatin matrix was noted and was evacuated. Six weeks following surgery, she had a complete neurologic recovery. The use of a hemostatic gelatin matrix to decrease bleeding from cannulated pedicles during pedicle screw insertion can result in inadvertent extravasation into the spinal canal resulting in ESCC even in the absence of an apparent medial pedicle breach. Given the dangers associated with the technique, we recommend that gelatin matrix products be used judiciously during pedicle screw insertion.

  8. Integrity of Narrow Epithelial Tubes in the C. elegans Excretory System Requires a Transient Luminal Matrix

    PubMed Central

    Ayala-Figueroa, Jesus; Parry, Jean M.; Pu, Pu; Hall, David H.

    2016-01-01

    Most epithelial cells secrete a glycoprotein-rich apical extracellular matrix that can have diverse but still poorly understood roles in development and physiology. Zona Pellucida (ZP) domain glycoproteins are common constituents of these matrices, and their loss in humans is associated with a number of diseases. Understanding of the functions, organization and regulation of apical matrices has been hampered by difficulties in imaging them both in vivo and ex vivo. We identified the PAN-Apple, mucin and ZP domain glycoprotein LET-653 as an early and transient apical matrix component that shapes developing epithelia in C. elegans. LET-653 has modest effects on shaping of the vulva and epidermis, but is essential to prevent lumen fragmentation in the very narrow, unicellular excretory duct tube. We were able to image the transient LET-653 matrix by both live confocal imaging and transmission electron microscopy. Structure/function and fluorescence recovery after photobleaching studies revealed that LET-653 exists in two separate luminal matrix pools, a loose fibrillar matrix in the central core of the lumen, to which it binds dynamically via its PAN domains, and an apical-membrane-associated matrix, to which it binds stably via its ZP domain. The PAN domains are both necessary and sufficient to confer a cyclic pattern of duct lumen localization that precedes each molt, while the ZP domain is required for lumen integrity. Ectopic expression of full-length LET-653, but not the PAN domains alone, could expand lumen diameter in the developing gut tube, where LET-653 is not normally expressed. Together, these data support a model in which the PAN domains regulate the ability of the LET-653 ZP domain to interact with other factors at the apical membrane, and this ZP domain interaction promotes expansion and maintenance of lumen diameter. These data identify a transient apical matrix component present prior to cuticle secretion in C. elegans, demonstrate critical roles for this matrix component in supporting lumen integrity within narrow bore tubes such as those found in the mammalian microvasculature, and reveal functional importance of the evolutionarily conserved ZP domain in this tube protecting activity. PMID:27482894

  9. Determination of organic acids in tissues and exudates of maize, lupin, and chickpea by high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Erro, Javier; Zamarreño, Angel M; Yvin, Jean-Claude; Garcia-Mina, Jose M

    2009-05-27

    This article describes a fast and simple methodology for the extraction and determination of organic acids in tissues and root exudates of maize, lupin, and chickpea by LC/MS/MS. Its main advantage is that it does not require sample prepurification before HPLC analysis or sample derivatization to improve sensibility. The results obtained showed good precision and accuracy, a recovery close to 100%, and no significant matrix effect. Moreover, the sensibility of the method is in general better than that of previously described methodologies, with detection limits between 15 and 900 pg injected.

  10. Routine low-level monitoring of polar pesticides and pesticide degradates by HPLC/ESI-MS: Evaluating long-term performance

    USGS Publications Warehouse

    Furlong, E.T.; Martin, Jeffrey D.; Werner, S.L.; Gates, Paul M.

    2002-01-01

    The sensitivity and selective determination of polar pesticides were analyzed using high-performance liquid chromatography/electrospray ionization-mass spectrometry (HPLC/ESI-MS). The effects of multiple operators and instruments on method performance were evaluated using 440 pairs of fortified reagent-water and blank reagent-water samples. The influence of varying environmental matrices on recovery and precision were also analyzed using 200 fortified ambient water samples and duplicate ambient water samples. The results show that compound stability in filtered water was matrix-, chemical class- and compound-dependent which ranged from 1 day to 2 weeks.

  11. Development of an LC-MS/MS method for the determination of endogenous cortisol in hair using (13)C3-labeled cortisol as surrogate analyte.

    PubMed

    Binz, Tina M; Braun, Ueli; Baumgartner, Markus R; Kraemer, Thomas

    2016-10-15

    Hair cortisol levels are increasingly applied as a measure for stress in humans and mammals. Cortisol is an endogenous compound and is always present within the hair matrix. Therefore, "cortisol-free hair matrix" is a critical point for any analytical method to accurately quantify especially low cortisol levels. The aim of this project was to modify current methods used for hair cortisol analysis to more accurately determine low endogenous cortisol concentrations in hair. For that purpose, (13)C3-labeled cortisol, which is not naturally present in hair (above 13C natural abundance levels), was used for calibration and comparative validation applying cortisol versus (13)C3-labeled cortisol. Cortisol was extracted from 20mg hair (standard sample amount) applying an optimized single step extraction protocol. An LC-MS/MS method was developed for the quantitative analysis of cortisol using either cortisol or (13)C3-cortisol as calibrators and D7-cortisone as internal standard (IS). The two methods (cortisol/(13)C3-labeled cortisol) were validated in a concentration range up to 500pg/mg and showed good linearity for both analytes (cortisol: R(2)=0.9995; (13)C3-cortisol R(2)=0.9992). Slight differences were observed for limit of detection (LOD) (0.2pg/mg/0.1pg/mg) and limit of quantification (LOQ) (1pg/mg/0.5pg/mg). Precision was good with a maximum deviation of 8.8% and 10% for cortisol and (13)C3-cortisol respectively. Accuracy and matrix effects were good for both analytes except for the quality control (QC) low cortisol. QC low (2.5pg/mg) showed matrix effects (126.5%, RSD 35.5%) and accuracy showed a deviation of 26% when using cortisol to spike. These effects are likely to be caused by the unknown amount of endogenous cortisol in the different hair samples used to determine validation parameters like matrix effect, LOQ and accuracy. No matrix effects were observed for the high QC (400pg/mg) samples. Recovery was good with 92.7%/87.3% (RSD 9.9%/6.2%) for QC low and 102.3%/82.1% (RSD 5.8%/11.4%) for QC high. After successful validation the applicability of the method could be proven. The study shows that the method is especially useful for determining low endogenous cortisol concentrations as they occur in cow hair for example. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Co-expression Network Approach to Studying the Effects of Botulinum Neurotoxin-A.

    PubMed

    Mukund, Kavitha; Ward, Samuel R; Lieber, Richard L; Subramaniam, Shankar

    2017-10-16

    Botulinum Neurotoxin A (BoNT-A) is a potent neurotoxin with several clinical applications.The goal of this study was to utilize co-expression network theory to analyze temporal transcriptional data from skeletal muscle after BoNT-A treatment. Expression data for 2000 genes (extracted using a ranking heuristic) served as the basis for this analysis. Using weighted gene co-expression network analysis (WGCNA), we identified 19 co-expressed modules, further hierarchically clustered into 5 groups. Quantifying average expression and co-expression patterns across these groups revealed temporal aspects of muscle's response to BoNT-A. Functional analysis revealed enrichment of group 1 with metabolism; group 5 with contradictory functions of atrophy and cellular recovery; and groups 2 and 3 with extracellular matrix (ECM) and non-fast fiber isoforms. Topological positioning of two highly ranked, significantly expressed genes- Dclk1 and Ostalpha within group 5 suggested possible mechanistic roles in recovery from BoNT-A induced atrophy. Phenotypic correlations of groups with titin and myosin protein content further emphasized the effect of BoNT-A on the sarcomeric contraction machinery in early phase of chemodenervation. In summary, our approach revealed a hierarchical functional response to BoNT-A induced paralysis with early metabolic and later ECM responses and identified putative biomarkers associated with chemodenervation. Additionally, our results provide an unbiased validation of the response documented in our previous workBotulinum Neurotoxin A (BoNT-A) is a potent neurotoxin with several clinical applications.The goal of this study was to utilize co-expression network theory to analyze temporal transcriptional data from skeletal muscle after BoNT-A treatment. Expression data for 2000 genes (extracted using a ranking heuristic) served as the basis for this analysis. Using weighted gene co-expression network analysis (WGCNA), we identified 19 co-expressed modules, further hierarchically clustered into 5 groups. Quantifying average expression and co-expression patterns across these groups revealed temporal aspects of muscle's response to BoNT-A. Functional analysis revealed enrichment of group 1 with metabolism; group 5 with contradictory functions of atrophy and cellular recovery; and groups 2 and 3 with extracellular matrix (ECM) and non-fast fiber isoforms. Topological positioning of two highly ranked, significantly expressed genes- Dclk1 and Ostalpha within group 5 suggested possible mechanistic roles in recovery from BoNT-A induced atrophy. Phenotypic correlations of groups with titin and myosin protein content further emphasized the effect of BoNT-A on the sarcomeric contraction machinery in early phase of chemodenervation. In summary, our approach revealed a hierarchical functional response to BoNT-A induced paralysis with early metabolic and later ECM responses and identified putative biomarkers associated with chemodenervation. Additionally, our results provide an unbiased validation of the response documented in our previous work.

  13. Novel silica surface charge density mediated control of the optical properties of embedded optically active materials and its application for fiber optic pH sensing at elevated temperatures.

    PubMed

    Wang, Congjun; Ohodnicki, Paul R; Su, Xin; Keller, Murphy; Brown, Thomas D; Baltrus, John P

    2015-02-14

    Silica and silica incorporated nanocomposite materials have been extensively studied for a wide range of applications. Here we demonstrate an intriguing optical effect of silica that, depending on the solution pH, amplifies or attenuates the optical absorption of a variety of embedded optically active materials with very distinct properties, such as plasmonic Au nanoparticles, non-plasmonic Pt nanoparticles, and the organic dye rhodamine B (not a pH indicator), coated on an optical fiber. Interestingly, the observed optical response to varying pH appears to follow the surface charge density of the silica matrix for all the three different optically active materials. To the best of our knowledge, this optical effect has not been previously reported and it appears universal in that it is likely that any optically active material can be incorporated into the silica matrix to respond to solution pH or surface charge density variations. A direct application of this effect is for optical pH sensing which has very attractive features that can enable minimally invasive, remote, real time and continuous distributed pH monitoring. Particularly, as demonstrated here, using highly stable metal nanoparticles embedded in an inorganic silica matrix can significantly improve the capability of pH sensing in extremely harsh environments which is of increasing importance for applications in unconventional oil and gas resource recovery, carbon sequestration, water quality monitoring, etc. Our approach opens a pathway towards possible future development of robust optical pH sensors for the most demanding environmental conditions. The newly discovered optical effect of silica also offers the potential for control of the optical properties of optically active materials for a range of other potential applications such as electrochromic devices.

  14. Characterization of Rare Earth Elements in in Clay Deposits Associated with Central Appalachian Coal Seams

    NASA Astrophysics Data System (ADS)

    Scott, M.; Verba, C.; Falcon, A.; Poston, J.; McKoy, M.

    2017-12-01

    Because of their multiple uses in clean energy technologies, rare earth elements (REE) are critical for national economic and energy security. With no current domestic source, supply remains a major concern for domestic security. Underclay - specifically the layer of stratum beneath a coal bed - is a potentially rich source of REE. This study focuses on the characterization and ion exchange recovery of REE from underclay samples from the Lower Freeport, Middle Kittanning, and Pittsburgh coal seams in West Virginia. Multimodal techniques provided quantitative assessments of REE-bearing mineral phases in select underclays and the influence of organic acid rock treatment on the recovery of REE from both exchangeable and crystalline mineral phases present. All samples are from extensively weathered horizons that contain abundant kaolinite and illite. Total REE concentrations range from 250-450 ppm and all samples have a HREE/LEEE ratio >20%. Rare earth element bearing minerals identified in the clay are monazite, xenotime, florencite, and crandallite. Our selective recovery approach is designed to isolate and recover REE through partial dissolution of the clay matrix and ion exchange rather than dissolution/recovery of phosphate or aluminosilicate bound REE. These results provide a better understanding of coal seam underclay, the affinity of REEs for specific ligands and colloids, and how the rock and ligands respond to different chemical treatments. These processes are important to the development and commercialization of efficient and cost effective methods to extract REE from domestic geologic deposits and recover into salable forms.

  15. Comparison of sample preparation methods combined with fast gas chromatography-mass spectrometry for ultratrace analysis of pesticide residues in baby food.

    PubMed

    Hercegová, Andrea; Dömötörová, Milena; Kruzlicová, Dása; Matisová, Eva

    2006-05-01

    Four sample preparation techniques were compared for the ultratrace analysis of pesticide residues in baby food: (a) modified Schenck's method based on ACN extraction with SPE cleaning; (b) quick, easy, cheap, effective, rugged, and safe (QuEChERS) method based on ACN extraction and dispersive SPE; (c) modified QuEChERS method which utilizes column-based SPE instead of dispersive SPE; and (d) matrix solid phase dispersion (MSPD). The methods were combined with fast gas chromatographic-mass spectrometric analysis. The effectiveness of clean-up of the final extract was determined by comparison of the chromatograms obtained. Time consumption, laboriousness, demands on glassware and working place, and consumption of chemicals, especially solvents, increase in the following order QuEChERS < modified QuEChERS < MSPD < modified Schenck's method. All methods offer satisfactory analytical characteristics at the concentration levels of 5, 10, and 100 microg/kg in terms of recoveries and repeatability. Recoveries obtained for the modified QuEChERS method were lower than for the original QuEChERS. In general the best LOQs were obtained for the modified Schenck's method. Modified QuEChERS method provides 21-72% better LOQs than the original method.

  16. Isotope dilution gas chromatography with mass spectrometry for the analysis of 4-octyl phenol, 4-nonylphenol, and bisphenol A in vegetable oils.

    PubMed

    Wu, Pinggu; Zhang, Liqun; Yang, Dajin; Zhang, Jing; Hu, Zhengyan; Wang, Liyuan; Ma, Bingjie

    2016-03-01

    By the combination of solid-phase extraction as well as isotope dilution gas chromatography with mass spectrometry, a sensitive and reliable method for the determination of endocrine-disrupting chemicals including bisphenol A, 4-octylphenol, and 4-nonylphenol in vegetable oils was established. The application of a silica/N-(n-propyl)ethylenediamine mixed solid-phase extraction cartridge achieved relatively low matrix effects for bisphenol A, 4-octylphenol, and 4-nonylphenol in vegetable oils. Experiments were designed to evaluate the effects of derivatization, and the extraction parameters were optimized. The estimated limits of detection and quantification for bisphenol A, 4-octylphenol, and 4-nonylphenol were 0.83 and 2.5 μg/kg, respectively. In a spiked experiment in vegetable oils, the recovery of the added bisphenol A was 97.5-110.3%, recovery of the added 4-octylphenol was 64.4-87.4%, and that of 4-nonylphenol was 68.2-89.3%. This sensitive method was then applied to real vegetable oil samples from Zhejiang Province of China, and none of the target compounds were detected. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Murine social stress results in long lasting voiding dysfunction.

    PubMed

    Butler, Stephan; Luz, Sandra; McFadden, Kile; Fesi, Joanna; Long, Christopher; Spruce, Lynn; Seeholzer, Steven; Canning, Douglas; Valentino, Rita; Zderic, Stephen

    2018-01-01

    Repeated exposure to social stress shifts the voiding phenotype in male mice leading to bladder wall remodeling and is associated with increased expression of the stress neuropeptide, corticotropin-releasing factor (CRF) in Barrington's nucleus neurons. In these studies, we set out to determine if the voiding phenotype could recover upon removal from the stressor. Male mice were exposed for 1h daily to an aggressor and the voiding phenotype was assessed at one month followed by randomization to three groups. One group underwent immediate sacrifice. Two groups were allowed a one month recovery from the social stress exposure with or without the addition of fluoxetine (1.2mg/ml) in their drinking water and repeat voiding patterns were measured prior to sacrifice. Social stress significantly increased bladder mass, bladder mass corrected for body weight, voided volumes, and decreased urinary frequency. The abnormal voiding phenotype persisted after a 1month recovery with no effect from the addition of fluoxetine. CRF mRNA in Barrington's nucleus was increased by social stress and remained elevated following recovery with no effect from the addition of fluoxetine. The mRNA and protein expression for the alpha 1 chains of type 1 and type III collagen was unchanged across all groups suggesting that changes in the extracellular matrix of the bladder are not responsible for the voiding phenotype. This persisting voiding dysfunction correlates with the persistent elevation of CRF mRNA expression in Barrington's nucleus. Copyright © 2017. Published by Elsevier Inc.

  18. Development and validation of a solid-phase extraction method coupled to liquid chromatography with fluorescence detection for the determination of fluoroquinolone residues in powdered infant formulae. Application to the analysis of samples from the Spanish and Latin American market.

    PubMed

    Rodriguez, E; Moreno-Bondi, M C; Marazuela, M D

    2008-10-31

    This paper describes a new method for the effective extraction, clean-up and chromatographic analysis of residues of four fluoroquinolones (ciprofloxacin, enrofloxacin, danofloxacin and sarafloxacin) in powdered infant formulae and follow-on preparations. Samples were reconstituted following the manufacturer's recommendations and treated with trichloroacetic acid in methanol 10% (w/v) for deproteinization. Two solid-phase extraction cartridges have been evaluated for sample clean-up and preconcentration, Strata Screen A and Strata X and the later provided the best recoveries for all the analytes tested. Chromatographic analysis has been carried out using a polar endcapped column (AQUA C(18)) and fluorescence detection, with lomefloxacin (LOME) as internal standard. Method validation has been performed according to European Commission Decision 2002/657/EC criteria, in terms of linearity, recovery, precision, specificity, decision limit (CC(alpha)) and detection capability (CC(beta)). Typical recoveries ranged between 70 and 110% at levels below and above the maximum residue limits of the target analytes in bovine milk, with an excellent intralab reproducibility (RSDs<7%). Matrix effects did not significantly affect method accuracy, as evidenced by analyzing different brands of milk. The method has been successfully applied to the analysis of 100 samples of infant and follow-on formulae of the Spanish and Latin American market, using LC-MS/MS as confirmatory technique.

  19. Scaffolds for peripheral nerve repair and reconstruction.

    PubMed

    Yi, Sheng; Xu, Lai; Gu, Xiaosong

    2018-06-02

    Trauma-associated peripheral nerve defect is a widespread clinical problem. Autologous nerve grafting, the current gold standard technique for the treatment of peripheral nerve injury, has many internal disadvantages. Emerging studies showed that tissue engineered nerve graft is an effective substitute to autologous nerves. Tissue engineered nerve graft is generally composed of neural scaffolds and incorporating cells and molecules. A variety of biomaterials have been used to construct neural scaffolds, the main component of tissue engineered nerve graft. Synthetic polymers (e.g. silicone, polyglycolic acid, and poly(lactic-co-glycolic acid)) and natural materials (e.g. chitosan, silk fibroin, and extracellular matrix components) are commonly used along or together to build neural scaffolds. Many other materials, including the extracellular matrix, glass fabrics, ceramics, and metallic materials, have also been used to construct neural scaffolds. These biomaterials are fabricated to create specific structures and surface features. Seeding supporting cells and/or incorporating neurotrophic factors to neural scaffolds further improve restoration effects. Preliminary studies demonstrate that clinical applications of these neural scaffolds achieve satisfactory functional recovery. Therefore, tissue engineered nerve graft provides a good alternative to autologous nerve graft and represents a promising frontier in neural tissue engineering. Copyright © 2018 Elsevier Inc. All rights reserved.

  20. Modeling Permeability Alteration in Diatomite Reservoirs During Steam Drive, SUPRI TR-113

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bhat, Suniti Kumar; Kovscek, Anthony R.

    1999-08-09

    There is an estimated 10 billion barrels of original oil in place (OOIP) in diatomaceous reservoirs in Kern County, California. These reservoirs have low permeability ranging from 0.1 to 10 mD. Injection pressure controlled steam drive has been found to be an effective way to recover oil from these reservoir. However, steam drive in these reservoirs has its own complications. The rock matrix is primarily silica (SiO2). It is a known fact that silica is soluble in hot water and its solubility varies with temperature and pH. Due to this fact, the rock matrix in diatomite may dissolve into themore » aqueous phase as the temperature at a location increases or it may precipitate from the aqueous phase onto the rock grains as the temperature decreases. Thus, during steam drive silica redistribution will occur in the reservoir along with oil recovery. This silica redistribution causes the permeability and porosity of the reservoir to change. Understanding and quantifying these silica redistribution effects on the reservoir permeability might prove to be a key aspect of designing a steam drive project in these formations.« less

  1. Dual morphology (fibres and particles) cellulosic filler for WPC materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Valente, Marco, E-mail: marco.valente@uniroma1.it; Tirillò, Jacopo; Quitadamo, Alessia, E-mail: alessia.quitadamo@uniroma1.it

    Wood-plastic composites (WPC) were fabricated by using a polyethylene (PE) matrix and filling it with wood flour in the amount of 30 wt.%, and compared with the same composites with further amount of 10 wt.% of cellulosic recycled fibres added. The materials were produced by turbomixing and subsequent moulding under pressure. Mechanical properties of both WPC and WPC with cellulosic recycled fibres were evaluated through mechanical and physical-chemical tests. Tensile tests clarified that a moderate reduction is strength is observed with the bare introduction of wood flour with respect to the neat PE matrix, whilst some recovery is offered bymore » the addition of recycled cellulose fibres. Even more promisingly, the elastic modulus of PE matrix is substantially improved by the addition of wood flour (around 8% on average) and much more so with the further addition of recycled cellulose (around 20% on average). The fracture surfaces from the tensile test were analysed by scanning electron microscope (SEM) indicating a reduction in microporosity as an effect of added cellulose. The water absorption test and the hardness measure (Shore D) were also performed. SEM analysis underlined the weak interface between both wood particle and cellulosic recycled fibres and matrix. The water absorption test showed a higher mass variation for pure WPC than WPC with cellulosic recycled fibres. The hardness measurement showed that the presence of cellulosic recycled fibres improves both superficial hardness of the composite and temperature resistance.« less

  2. Determination of pesticide residues in samples of green minor crops by gas chromatography and ultra performance liquid chromatography coupled to tandem quadrupole mass spectrometry.

    PubMed

    Walorczyk, Stanisław; Drożdżyński, Dariusz; Kierzek, Roman

    2015-01-01

    A method was developed for pesticide analysis in samples of high chlorophyll content belonging to the group of minor crops. A new type of sorbent, known as ChloroFiltr, was employed for dispersive-solid phase extraction cleanup (dispersive-SPE) to reduce the unwanted matrix background prior to concurrent analysis by gas chromatography and ultra-performance liquid chromatography coupled to tandem quadrupole mass spectrometry (GC-MS/MS and UPLC-MS/MS). Validation experiments were carried out on green, unripe plants of lupin, white mustard and sorghum. The overall recoveries at the three spiking levels of 0.01, 0.05 and 0.5 mg kg(-1) fell in the range between 68 and 120% (98% on average) and 72-104% (93% on average) with relative standard deviation (RSD) values between 2 and 19% (7% on average) and 3-16% (6% on average) by GC-MS/MS and UPLC-MS/MS technique, respectively. Because of strong enhancement or suppression matrix effects (absolute values >20%) which were exhibited by about 80% of the pesticide and matrix combinations, acceptably accurate quantification was achieved by using matrix-matched standards. Up to now, the proposed method has been successfully used to study the dissipation patterns of pesticides after application on lupin, white mustard, soya bean, sunflower and field bean in experimental plot trials conducted in Poland. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Simultaneous determination and qualitative analysis of six types of components in Naoxintong capsule by miniaturized matrix solid-phase dispersion extraction coupled with ultra high-performance liquid chromatography with photodiode array detection and quadrupole time-of-flight mass spectrometry.

    PubMed

    Wang, Huilin; Jiang, Yan; Ding, Mingya; Li, Jin; Hao, Jia; He, Jun; Wang, Hui; Gao, Xiu-Mei; Chang, Yan-Xu

    2018-02-03

    A simple and effective sample preparation process based on miniaturized matrix solid-phase dispersion was developed for simultaneous determination of phenolic acids (gallic acid, chlorogenic acid, ferulic acid, 3,5-dicaffeoylqunic acid, 1,5-dicaffeoylqunic acid, rosmarinic acid, lithospermic acid, and salvianolic acid B), flavonoids (kaempferol-3-O-rutinoside, calycosin, and formononetin), lactones (ligustilide and butyllidephthalide), monoterpenoids (paeoniflorin), phenanthraquinones (cryptotanshinone), and furans (5-hydroxymethylfurfural) in Naoxintong capsule by ultra high-performance liquid chromatography. The optimized condition was that 25 mg Naoxintong powder was blended homogeneously with 100 mg Florisil PR for 4 min. One milliliter of methanol/water (75:25, v/v) acidified by 0.05% formic acid was selected to elute all components. It was found that the recoveries of the six types of components ranged from 61.36 to 96.94%. The proposed miniaturized matrix solid-phase dispersion coupled with ultra high-performance liquid chromatography was successfully applied to simultaneous determination of the six types of components in Naoxintong capsules. The results demonstrated that the proposed miniaturized matrix solid-phase dispersion coupled with ultra high-performance liquid chromatography could be used as an environmentally friendly tool for the extraction and determination of multiple bioactive components in natural products. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Dual morphology (fibres and particles) cellulosic filler for WPC materials

    NASA Astrophysics Data System (ADS)

    Valente, Marco; Tirillò, Jacopo; Quitadamo, Alessia; Santulli, Carlo

    2016-05-01

    Wood-plastic composites (WPC) were fabricated by using a polyethylene (PE) matrix and filling it with wood flour in the amount of 30 wt.%, and compared with the same composites with further amount of 10 wt.% of cellulosic recycled fibres added. The materials were produced by turbomixing and subsequent moulding under pressure. Mechanical properties of both WPC and WPC with cellulosic recycled fibres were evaluated through mechanical and physical-chemical tests. Tensile tests clarified that a moderate reduction is strength is observed with the bare introduction of wood flour with respect to the neat PE matrix, whilst some recovery is offered by the addition of recycled cellulose fibres. Even more promisingly, the elastic modulus of PE matrix is substantially improved by the addition of wood flour (around 8% on average) and much more so with the further addition of recycled cellulose (around 20% on average). The fracture surfaces from the tensile test were analysed by scanning electron microscope (SEM) indicating a reduction in microporosity as an effect of added cellulose. The water absorption test and the hardness measure (Shore D) were also performed. SEM analysis underlined the weak interface between both wood particle and cellulosic recycled fibres and matrix. The water absorption test showed a higher mass variation for pure WPC than WPC with cellulosic recycled fibres. The hardness measurement showed that the presence of cellulosic recycled fibres improves both superficial hardness of the composite and temperature resistance.

  5. In house validation of a high resolution mass spectrometry Orbitrap-based method for multiple allergen detection in a processed model food.

    PubMed

    Pilolli, Rosa; De Angelis, Elisabetta; Monaci, Linda

    2018-02-13

    In recent years, mass spectrometry (MS) has been establishing its role in the development of analytical methods for multiple allergen detection, but most analyses are being carried out on low-resolution mass spectrometers such as triple quadrupole or ion traps. In this investigation, performance provided by a high resolution (HR) hybrid quadrupole-Orbitrap™ MS platform for the multiple allergens detection in processed food matrix is presented. In particular, three different acquisition modes were compared: full-MS, targeted-selected ion monitoring with data-dependent fragmentation (t-SIM/dd2), and parallel reaction monitoring. In order to challenge the HR-MS platform, the sample preparation was kept as simple as possible, limited to a 30-min ultrasound-aided protein extraction followed by clean-up with disposable size exclusion cartridges. Selected peptide markers tracing for five allergenic ingredients namely skim milk, whole egg, soy flour, ground hazelnut, and ground peanut were monitored in home-made cookies chosen as model processed matrix. Timed t-SIM/dd2 was found the best choice as a good compromise between sensitivity and accuracy, accomplishing the detection of 17 peptides originating from the five allergens in the same run. The optimized method was validated in-house through the evaluation of matrix and processing effects, recoveries, and precision. The selected quantitative markers for each allergenic ingredient provided quantification of 60-100 μg ingred /g allergenic ingredient/matrix in incurred cookies.

  6. Adjustment of pesticide concentrations for temporal changes in analytical recovery, 1992–2010

    USGS Publications Warehouse

    Martin, Jeffrey D.; Eberle, Michael

    2011-01-01

    Recovery is the proportion of a target analyte that is quantified by an analytical method and is a primary indicator of the analytical bias of a measurement. Recovery is measured by analysis of quality-control (QC) water samples that have known amounts of target analytes added ("spiked" QC samples). For pesticides, recovery is the measured amount of pesticide in the spiked QC sample expressed as a percentage of the amount spiked, ideally 100 percent. Temporal changes in recovery have the potential to adversely affect time-trend analysis of pesticide concentrations by introducing trends in apparent environmental concentrations that are caused by trends in performance of the analytical method rather than by trends in pesticide use or other environmental conditions. This report presents data and models related to the recovery of 44 pesticides and 8 pesticide degradates (hereafter referred to as "pesticides") that were selected for a national analysis of time trends in pesticide concentrations in streams. Water samples were analyzed for these pesticides from 1992 through 2010 by gas chromatography/mass spectrometry. Recovery was measured by analysis of pesticide-spiked QC water samples. Models of recovery, based on robust, locally weighted scatterplot smooths (lowess smooths) of matrix spikes, were developed separately for groundwater and stream-water samples. The models of recovery can be used to adjust concentrations of pesticides measured in groundwater or stream-water samples to 100 percent recovery to compensate for temporal changes in the performance (bias) of the analytical method.

  7. Multi-residue analysis of 26 organochlorine pesticides in Alpinia oxyphylla by GC-ECD after solid phase extraction and acid cleanup.

    PubMed

    Zhao, Xiangsheng; Zhou, Yakui; Kong, Weijun; Gong, Bao; Chen, Deli; Wei, Jianhe; Yang, Meihua

    2016-04-01

    A simple and effective multi-residue method was developed and validated for the analysis of 26 organochlorine pesticide residues in Alpinia oxyphylla by a gas chromatography with an electron capture detector (GC-ECD). The target pesticides were extracted by sonication and cleaned up with florisil solid phase extraction and sulphuric acid. Some crucial parameters, including extraction solvent and time, sorbent type, elute solvent and concentration of sulphuric acid were optimized to improve the performance of sample preparation procedure. The optimized method gave high sensitivity with detection limit ranging from 0.1 to 2.0μg/kg. Matrix-matched calibration was employed for the quantification, and a wide linear range (from 1.0 to 1000μg/kg) with r(2) values ranging from 0.9971 to 0.9998 was obtained. For the majority of the tested pesticides, the average recoveries were in acceptable range (between 70% and 110%) with relative standard deviation values below 15.0%. Matrix effect was evaluated for target compounds through the study of ratio of peak area obtained in the solvent and blank matrix. The proposed method was applied to simultaneously analyze 26 pesticides in 55 batches of Alpinia oxyphylla samples. 3 samples were found to be positive with four pesticides (α-BHC, quintozene, trans-chlordane and op'-DDD), which were confirmed by gas chromatography-mass spectrometry (GC-MS) in selective ion monitoring (SIM) mode. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. UHPLC-MS/MS method for the quantitation of penicillin G and metabolites in citrus fruit using internal standards.

    PubMed

    Canzani, Daniele; Hsieh, Kevin; Standland, Matthew; Hammack, Walter; Aldeek, Fadi

    2017-02-15

    Penicillin G has been applied to citrus trees as a potential treatment in the fight against Huanglongbing (HLB). Here, we have developed and validated a method to identify and quantitate penicillin G and two of its metabolites, penillic acid and penilloic acid, in citrus fruit using ultra high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). This method improves upon a previous method by incorporating isotopically labeled internal standards, namely, penillic acid-D 5 , and penilloic acid-D 5 . These standards greatly enhanced the accuracy and precision of our measurements by compensating for recovery losses, degradation, and matrix effects. When 2g of citrus fruit sample is extracted, the limits of detection (LOD) were determined to be 0.1ng/g for penicillin G and penilloic acid, and 0.25ng/g for penillic acid. At fortification levels of 0.1, 0.25, 1, and 10ng/g, absolute recoveries for penillic and penilloic acids were generally between 50-70%. Recoveries corrected with the isotopically labeled standards were approximately 90-110%. This method will be useful for the identification and quantitation of drug residues and their degradation products using isotopically labeled standards and UHPLC-MS/MS. Published by Elsevier B.V.

  9. Effect of stress on the diffusion kinetics of methane during gas desorption in coal matrix under different equilibrium pressures

    NASA Astrophysics Data System (ADS)

    Li, Chengwu; Xue, Honglai; Hu, Po; Guan, Cheng; Liu, Wenbiao

    2018-06-01

    Stress has a significant influence on gas diffusion, which is a key factor for methane recovery in coal mines. In this study, a series of experiments were performed to investigate effect of stress on the gas diffusivity during desorption in tectonic coal. Additionally, the desorbed data were modeled using the unipore and bidisperse models. The results show that the bidisperse model better describes the diffusion kinetics than the unipore model in this study. Additionally, the modeling results using the bidisperse approach suggest that the stress impact on the macropore diffusivity is greater than the stress on the micropore diffusivity. Under the same equilibrium pressure, the diffusivity varies with stress according to a four-stage function, which shows an ‘M-shape’. As the equilibrium gas pressure increased from 0.6 to 1.7 MPa, the critical point between stage 2 and stage 3 and between stage 3 and stage 4 transferred to a low stress. This difference is attributed to the gas pressure effects on the physical and mechanical properties of coal. These observations indicate that both the stress and gas pressure can significantly impact gas diffusion and may have significant implications on methane recovery in coal mines.

  10. Kronecker-Basis-Representation Based Tensor Sparsity and Its Applications to Tensor Recovery.

    PubMed

    Xie, Qi; Zhao, Qian; Meng, Deyu; Xu, Zongben

    2017-08-02

    It is well known that the sparsity/low-rank of a vector/matrix can be rationally measured by nonzero-entries-number ($l_0$ norm)/nonzero- singular-values-number (rank), respectively. However, data from real applications are often generated by the interaction of multiple factors, which obviously cannot be sufficiently represented by a vector/matrix, while a high order tensor is expected to provide more faithful representation to deliver the intrinsic structure underlying such data ensembles. Unlike the vector/matrix case, constructing a rational high order sparsity measure for tensor is a relatively harder task. To this aim, in this paper we propose a measure for tensor sparsity, called Kronecker-basis-representation based tensor sparsity measure (KBR briefly), which encodes both sparsity insights delivered by Tucker and CANDECOMP/PARAFAC (CP) low-rank decompositions for a general tensor. Then we study the KBR regularization minimization (KBRM) problem, and design an effective ADMM algorithm for solving it, where each involved parameter can be updated with closed-form equations. Such an efficient solver makes it possible to extend KBR to various tasks like tensor completion and tensor robust principal component analysis. A series of experiments, including multispectral image (MSI) denoising, MSI completion and background subtraction, substantiate the superiority of the proposed methods beyond state-of-the-arts.

  11. Chitosan from shrimp shells: A renewable sorbent applied to the clean-up step of the QuEChERS method in order to determine multi-residues of veterinary drugs in different types of milk.

    PubMed

    Arias, Jean Lucas de Oliveira; Schneider, Antunielle; Batista-Andrade, Jahir Antonio; Vieira, Augusto Alves; Caldas, Sergiane Souza; Primel, Ednei Gilberto

    2018-02-01

    Clean extracts are essential in LC-MS/MS, since the matrix effect can interfere in the analysis. Alternative materials which can be used as sorbents, such as chitosan in the clean-up step, are cheap and green options. In this study, chitosan from shrimp shell waste was evaluated as a sorbent in the QuEChERS method in order to determine multi-residues of veterinary drugs in different types of milk, i. e., fatty matrices. After optimization, the method showed correlation coefficients above 0.99, LOQs ranged between 1 and 50μgkg -1 and recoveries ranged between 62 and 125%, with RSD<20% for all veterinary drugs in all types of milk under study. The clean-up step which employed chitosan proved to be effective, since it reduced both the matrix effect (from values between -40 and -10% to values from -10 to +10%) and the extract turbidity (up to 95%). When the proposed method was applied to different milk samples, residues of albendazole (49μgkg -1 ), sulfamethazine (

  12. Ionic liquid based vortex assisted liquid-liquid microextraction combined with liquid chromatography mass spectrometry for the determination of bisphenols in thermal papers with the aid of response surface methodology.

    PubMed

    Asati, Ankita; Satyanarayana, G N V; Panchal, Smita; Thakur, Ravindra Singh; Ansari, Nasreen G; Patel, Devendra K

    2017-08-04

    A sensitive, rapid and efficient ionic liquid-based vortex assisted liquid-liquid microextraction (IL-VALLME) with Liquid Chromatography Mass spectrometry (LC-MS/MS) method is proposed for the determination of bisphenols in thermal paper. Extraction factors were systematically optimized by response surface methodology. Experimental factors showing significant effects on the analytical responses were evaluated using design of experiment. The limit of detection for Bisphenol-A (BPA) and Bisphenol-S (BPS) in thermal paper were 1.25 and 0.93μgkg -1 respectively. The dynamic linearity range for BPA was between 4 and 100μgkg -1 and the determination of coefficient (R 2 ) was 0.996. The values of the same parameters were 3-100μgkg -1 and 0.998 for BPS. The extraction recoveries of BPA and BPS in thermal paper were 101% and 99%. Percent relative standard deviation (% RSD) for matrix effect and matrix match effects were not more than 10%, for both bisphenols. The proposed method uses a statistical approach for the analysis of bisphenols in environmental samples, and is easy, rapid, requires minimum organic solvents and efficient. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Analysis of radioactive strontium-90 in food by Čerenkov liquid scintillation counting.

    PubMed

    Pan, Jingjing; Emanuele, Kathryn; Maher, Eileen; Lin, Zhichao; Healey, Stephanie; Regan, Patrick

    2017-08-01

    A simple liquid scintillation counting method using DGA/TRU resins for removal of matrix/radiometric interferences, Čerenkov counting for measuring 90 Y, and EDXRF for quantifying Y recovery was validated for analyzing 90 Sr in various foods. Analysis of samples containing energetic β emitters required using TRU resin to avoid false detection and positive bias. Additional 34% increase in Y recovery was obtained by stirring the resin while eluting Y with H 2 C 2 O 4 . The method showed acceptable accuracy (±10%), precision (10%), and detectability (~0.09Bqkg -1 ). Published by Elsevier Ltd.

  14. Thermal, creep-recovery and viscoelastic behavior of high density polyethylene/hydroxyapatite nano particles for bone substitutes: effects of gamma radiation.

    PubMed

    Alothman, Othman Y; Fouad, H; Al-Zahrani, S M; Eshra, Ayman; Al Rez, Mohammed Fayez; Ansari, S G

    2014-08-28

    High Density Polyethylene (HDPE) is one of the most often used polymers in biomedical applications. The limitations of HDPE are its visco-elastic behavior, low modulus and poor bioactivity. To improve HDPE properties, HA nanoparticles can be added to form polymer composite that can be used as alternatives to metals for bone substitutes and orthopaedic implant applications. In our previous work (BioMedical Engineering OnLine 2013), different ratios of HDPE/HA nanocomposites were prepared using melt blending in a co-rotating intermeshing twin screw extruder. The accelerated aging effects on the tensile properties and torsional viscoelastic behavior (storage modulus (G') and Loss modulus (G")) at 80°C of irradiated and non-irradiated HDPE/HA was investigated. Also the thermal behavior of HDPE/HA were studied. In this study, the effects of gamma irradiation on the tensile viscoelastic behavior (storage modulus (E') and Loss modulus (E")) at 25°C examined for HDPE/HA nanocomposites at different frequencies using Dynamic Mechanical Analysis (DMA). The DMA was also used to analyze creep-recovery and relaxation properties of the nanocomposites. To analyze the thermal behavior of the HDPE/HA nanocomposite, Differential Scanning Calorimetry (DSC) was used. The microscopic examination of the cryogenically fractured surface revealed a reasonable distribution of HA nanoparticles in the HDPE matrix. The DMA showed that the tensile storage and loss modulus increases with increasing the HA nanoparticles ratio and the test frequency. The creep-recovery behavior improves with increasing the HA nanoparticle content. Finally, the results indicated that the crystallinity, viscoelastic, creep recovery and relaxation behavior of HDPE nanocomposite improved due to gamma irradiation. Based on the experimental results, it is found that prepared HDPE nanocomposite properties improved due to the addition of HA nanoparticles and irradiation. So, the prepared HDPE/HA nanocomposite appears to have fairly good comprehensive properties that make it a good candidate as bone substitute.

  15. Liquid electrode plasma-optical emission spectrometry combined with solid-phase preconcentration for on-site analysis of lead.

    PubMed

    Barua, Suman; Rahman, Ismail M M; Alam, Iftakharul; Miyaguchi, Maho; Sawai, Hikaru; Maki, Teruya; Hasegawa, Hiroshi

    2017-08-15

    A relatively rapid and precise method is presented for the determination of lead in aqueous matrix. The method consists of analyte quantitation using the liquid electrode plasma-optical emission spectrometry (LEP-OES) coupled with selective separation/preconcentration by solid-phase extraction (SPE). The impact of operating variables on the retention of lead in SPEs such as pH, flow rate of the sample solution; type, volume, flow rate of the eluent; and matrix effects were investigated. Selective SPE-separation/preconcentration minimized the interfering effect due to manganese in solution and limitations in lead-detection in low-concentration samples by LEP-OES. The LEP-OES operating parameters such as the electrical conductivity of sample solution; applied voltage; on-time, off-time, pulse count for applied voltage; number of measurements; and matrix effects have also been optimized to obtain a distinct peak for the lead at λ max =405.8nm. The limit of detection (3σ) and the limit of quantification (10σ) for lead determination using the technique were found as 1.9 and 6.5ng mL -1 , respectively. The precision, as relative standard deviation, was lower than 5% at 0.1μg mL -1 Pb, and the preconcentration factor was found to be 187. The proposed method was applied to the analysis of lead contents in the natural aqueous matrix (recovery rate:>95%). The method accuracy was verified using certified reference material of wastewaters: SPS-WW1 and ERM-CA713. The results from LEP-OES were in good agreement with inductively coupled plasma optical emission spectrometry measurements of the same samples. The application of the method is rapid (≤5min, without preconcentration) with a reliable detection limit at trace levels. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Salient Object Detection via Structured Matrix Decomposition.

    PubMed

    Peng, Houwen; Li, Bing; Ling, Haibin; Hu, Weiming; Xiong, Weihua; Maybank, Stephen J

    2016-05-04

    Low-rank recovery models have shown potential for salient object detection, where a matrix is decomposed into a low-rank matrix representing image background and a sparse matrix identifying salient objects. Two deficiencies, however, still exist. First, previous work typically assumes the elements in the sparse matrix are mutually independent, ignoring the spatial and pattern relations of image regions. Second, when the low-rank and sparse matrices are relatively coherent, e.g., when there are similarities between the salient objects and background or when the background is complicated, it is difficult for previous models to disentangle them. To address these problems, we propose a novel structured matrix decomposition model with two structural regularizations: (1) a tree-structured sparsity-inducing regularization that captures the image structure and enforces patches from the same object to have similar saliency values, and (2) a Laplacian regularization that enlarges the gaps between salient objects and the background in feature space. Furthermore, high-level priors are integrated to guide the matrix decomposition and boost the detection. We evaluate our model for salient object detection on five challenging datasets including single object, multiple objects and complex scene images, and show competitive results as compared with 24 state-of-the-art methods in terms of seven performance metrics.

  17. Dysprosium sorption by polymeric composite bead: robust parametric optimization using Taguchi method.

    PubMed

    Yadav, Kartikey K; Dasgupta, Kinshuk; Singh, Dhruva K; Varshney, Lalit; Singh, Harvinderpal

    2015-03-06

    Polyethersulfone-based beads encapsulating di-2-ethylhexyl phosphoric acid have been synthesized and evaluated for the recovery of rare earth values from the aqueous media. Percentage recovery and the sorption behavior of Dy(III) have been investigated under wide range of experimental parameters using these beads. Taguchi method utilizing L-18 orthogonal array has been adopted to identify the most influential process parameters responsible for higher degree of recovery with enhanced sorption of Dy(III) from chloride medium. Analysis of variance indicated that the feed concentration of Dy(III) is the most influential factor for equilibrium sorption capacity, whereas aqueous phase acidity influences the percentage recovery most. The presence of polyvinyl alcohol and multiwalled carbon nanotube modified the internal structure of the composite beads and resulted in uniform distribution of organic extractant inside polymeric matrix. The experiment performed under optimum process conditions as predicted by Taguchi method resulted in enhanced Dy(III) recovery and sorption capacity by polymeric beads with minimum standard deviation. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Determination of parabens and endocrine-disrupting alkylphenols in soil by gas chromatography-mass spectrometry following matrix solid-phase dispersion or in-column microwave-assisted extraction: a comparative study.

    PubMed

    Pérez, R A; Albero, B; Miguel, E; Sánchez-Brunete, C

    2012-03-01

    Two rapid methods were evaluated for the simultaneous extraction of seven parabens and two alkylphenols from soil based on matrix solid-phase dispersion (MSPD) and microwave-assisted extraction (MAE). Soil extracts were derivatized with N,O-bis(trimethylsilyl)trifluoroacetamide and analyzed by gas chromatography with mass spectrometry. Extraction and clean-up of samples were carried out by both methods in a single step. A glass sample holder, inside the microwave cell, was used in MAE to allow the simultaneous extraction and clean-up of samples and shorten the MAE procedure. The detection limits achieved by MSPD were lower than those obtained by MAE because the presence of matrix interferences increased with this extraction method. The extraction yields obtained by MSPD and MAE for three different types of soils were compared. Both procedures showed good recoveries and sensitivity for the determination of parabens and alkylphenols in two of the soils assayed, however, only MSPD yielded good recoveries with the other soil. Finally, MSPD was applied to the analysis of soils collected in different sites of Spain. In most of the samples analyzed, methylparaben and butylparaben were detected at levels ranging from 1.21 to 8.04 ng g(-1) dry weight and 0.48 to 1.02 ng g(-1) dry weight, respectively.

  19. Detachment of affinity-captured bioparticles by elastic deformation of a macroporous hydrogel

    PubMed Central

    Dainiak, Maria B.; Kumar, Ashok; Galaev, Igor Yu.; Mattiasson, Bo

    2006-01-01

    Adsorption of bioparticles to affinity surfaces involves polyvalent interactions, complicating greatly the recovery of the adsorbed material. A unique system for the efficient binding and release of different cells and particles is described. Affinity-bound bioparticles and synthetic particles are detached from the macroporous hydrogel matrix, a so-called cryogel, when the cryogel undergoes elastic deformation. The particle detachment upon elastic deformation is believed to be due to breaking of many of the multipoint attachments between the particles and the affinity matrix and the change in the distance between affinity ligands when the matrix is deformed. However, no release of affinity-bound protein occurred upon elastic deformation. The phenomenon of particle detachment upon elastic deformation is believed to be of a generic nature, because it was demonstrated for a variety of bioparticles of different sizes and for synthetic particles, for different ligand–receptor pairs (IgG–protein A, sugar–ConA, metal ion–chelating ligand), and when the deformation was caused by either external forces (mechanical deformation) or internal forces (the shrinkage of thermosensitive, macroporous hydrogel upon an increase in temperature). The elasticity of cryogel monoliths ensures high recovery of captured cells under mild conditions, with highly retained viability. This property, along with their continuous porous structure makes cryogel monoliths very attractive for applications in affinity cell separation. PMID:16418282

  20. Dynamics of VEGF matrix-retention in vascular network patterning

    NASA Astrophysics Data System (ADS)

    Köhn-Luque, A.; de Back, W.; Yamaguchi, Y.; Yoshimura, K.; Herrero, M. A.; Miura, T.

    2013-12-01

    Vascular endothelial growth factor (VEGF) is a central regulator of blood vessel morphogenesis, although its role in patterning of endothelial cells into vascular networks is not fully understood. It has been suggested that binding of soluble VEGF to extracellular matrix components causes spatially restricted cues that guide endothelial cells into network patterns. Yet, current evidence for such a mechanism remains indirect. In this study, we quantitatively analyse the dynamics of VEGF retention in a controlled in vitro situation of human umbilical vascular endothelial cells (HUVECs) in Matrigel. We show that fluorescent VEGF accumulates in pericellular areas and colocalizes with VEGF binding molecules. Analysis of fluorescence recovery after photobleaching reveals that binding/unbinding to matrix molecules dominates VEGF dynamics in the pericellular region. Computational simulations using our experimental measurements of kinetic parameters show that matrix retention of chemotactic signals can lead to the formation of reticular cellular networks on a realistic timescale. Taken together, these results show that VEGF binds to matrix molecules in proximity of HUVECs in Matrigel, and suggest that bound VEGF drives vascular network patterning.

  1. Biomimetic hydrogels direct spinal progenitor cell differentiation and promote functional recovery after spinal cord injury

    NASA Astrophysics Data System (ADS)

    Geissler, Sydney A.; Sabin, Alexandra L.; Besser, Rachel R.; Gooden, Olivia M.; Shirk, Bryce D.; Nguyen, Quan M.; Khaing, Zin Z.; Schmidt, Christine E.

    2018-04-01

    Objective. Demyelination that results from disease or traumatic injury, such as spinal cord injury (SCI), can have a devastating effect on neural function and recovery. Many researchers are examining treatments to minimize demyelination by improving oligodendrocyte availability in vivo. Transplantation of stem and oligodendrocyte progenitor cells is a promising option, however, trials are plagued by undirected differentiation. Here we introduce a biomaterial that has been optimized to direct the differentiation of neural progenitor cells (NPCs) toward oligodendrocytes as a cell delivery vehicle after SCI. Approach. A collagen-based hydrogel was modified to mimic the mechanical properties of the neonatal spinal cord, and components present in the developing extracellular matrix were included to provide appropriate chemical cues to the NPCs to direct their differentiation toward oligodendrocytes. The hydrogel with cells was then transplanted into a unilateral cervical contusion model of SCI to examine the functional recovery with this treatment. Six behavioral tests and histological assessment were performed to examine the in vivo response to this treatment. Main results. Our results demonstrate that we can achieve a significant increase in oligodendrocyte differentiation of NPCs compared to standard culture conditions using a three-component biomaterial composed of collagen, hyaluronic acid, and laminin that has mechanical properties matched to those of neonatal neural tissue. Additionally, SCI rats with hydrogel transplants, with and without NPCs, showed functional recovery. Animals transplanted with hydrogels with NPCs showed significantly increased functional recovery over six weeks compared to the media control group. Significance. The three-component hydrogel presented here has the potential to provide cues to direct differentiation in vivo to encourage regeneration of the central nervous system.

  2. Study of matrix effects on the direct trace analysis of acidic pesticides in water using various liquid chromatographic modes coupled to tandem mass spectrometric detection.

    PubMed

    Dijkman, E; Mooibroek, D; Hoogerbrugge, R; Hogendoorn, E; Sancho, J V; Pozo, O; Hernández, F

    2001-08-10

    This study investigated the effects of matrix interferences on the analytical performance of a triple quadrupole mass spectrometric (MS-MS) detector coupled to various reversed-phase liquid chromatographic (LC) modes for the on-line determination of various types of acidic herbicides in water using external calibration for quantification of the analytes tested at a level of 0.4 microg/l. The LC modes included (i) a single-column configuration (LC), (ii) precolumn switching (PC-LC) and (iii) coupled-column LC (LC-LC). As regards detection, electrospray (ESI) and atmospheric pressure chemical ionization (APCI) in both positive (PI) and negative (NI) ionization modes were examined. Salinity and dissolved organic carbon (DOC) were selected as interferences to study matrix effects in this type of analysis. Therefore, Milli-Q and tap water samples both fortified with 12 mg/l DOC and spiked with sulfometuron-methyl, bentazone, bromoxynil, 2-methyl-4-chlorophenoxyacetic acid, and 2-methyl-4-chlorophenoxypropionic acid at a level of about 0.4 microg/l were analyzed with the various LC-MS approaches. Direct sample injection was performed with volumes of 0.25 ml or 2.0 ml on a column of 2.1 mm I.D. or 4.6 mm I.D. for the ESI and APCI modes, respectively. The recovery data were used to compare and evaluate the analytical performance of the various LC approaches. As regards matrix effects, the salinity provided a dramatic decrease in response for early eluting analytes (k value of about 1) when using the LC mode. Both PC-LC and LC-LC efficiently eliminated this problem. The high DOC content hardly effected the responses of analytes in the ESI mode, while in most cases the responses increased when using APCI-MS-MS detection. Of all the tested configurations, LC-LC-ESI-MS-MS with the column combination Discovery C18/ABZ+ was the most favorable as regards elimination of matrix effects and provided reliable quantification of all compounds using external calibration at the tested low level. The major observed effects were verified with statistical evaluation of the data employing backwards ordinary least-square regression. All tested column-switching modes hyphenated to ESI- or APCI-MS-MS allowed the on-line multi-residue analysis of acidic pesticides in the reference water down to a level of 0.1 microg/l in less than 10 min, emphasizing the feasibility of such an approach in this field of analysis.

  3. Pesticide extraction from table grapes and plums using ionic liquid based dispersive liquid-liquid microextraction.

    PubMed

    Ravelo-Pérez, Lidia M; Hernández-Borges, Javier; Herrera-Herrera, Antonio V; Rodríguez-Delgado, Miguel Angel

    2009-12-01

    Room temperature ionic liquids (RTILs) have been used as extraction solvents in dispersive liquid-liquid microextraction (DLLME) for the determination of eight multi-class pesticides (i.e. thiophanate-methyl, carbofuran, carbaryl, tebuconazole, iprodione, oxyfluorfen, hexythiazox, and fenazaquin) in table grapes and plums. The developed method involves the combination of DLLME and high-performance liquid chromatography with diode array detection. Samples were first homogenized and extracted with acetonitrile. After evaporation and reconstitution of the extract in water containing sodium chloride, a quick DLLME procedure that used the ionic liquid 1-hexyl-3-methylimidazolium hexafluorophosphate ([C(6)MIM][PF(6)]) and methanol was developed. The RTIL dissolved in a very small volume of acetonitrile was directed injected in the chromatographic system. The comparison between the calibration curves obtained from standards and from spiked sample extracts (matrix-matched calibration) showed the existence of a strong matrix effect for most of the analyzed pesticides. A recovery study was also developed with five consecutive extractions of the two types of fruits spiked at three concentration levels. Mean recovery values were in the range of 72-100% for table grapes and 66-105% for plum samples (except for thiophanate-methyl and carbofuran, which were 64-75% and 58-66%, respectively). Limits of detection (LODs) were in the range 0.651-5.44 microg/kg for table grapes and 0.902-6.33 microg/kg for plums, representing LODs below the maximum residue limits (MRLs) established by the European Union in these fruits. The potential of the method was demonstrated by analyzing 12 commercial fruit samples (six of each type).

  4. Ammonia Gas Sensing Behavior of Tanninsulfonic Acid Doped Polyaniline-TiO2 Composite

    PubMed Central

    Bairi, Venu Gopal; Bourdo, Shawn E.; Sacre, Nicolas; Nair, Dev; Berry, Brian C.; Biris, Alexandru S.; Viswanathan, Tito

    2015-01-01

    A highly active tannin doped polyaniline-TiO2 composite ammonia gas sensor was developed and the mechanism behind the gas sensing activity was reported for the first time. A tanninsulfonic acid doped polyaniline (TANIPANI)-titanium dioxide nanocomposite was synthesized by an in situ polymerization of aniline in the presence of tanninsulfonic acid and titanium dioxide nanoparticles. X-ray diffraction and thermogravimetric analysis were utilized to determine the incorporation of TiO2 in TANIPANI matrix. UV-Visible and infrared spectroscopy studies provided information about the electronic interactions among tannin, polyaniline, and TiO2. Scanning electron microscopy (SEM) along with energy dispersive X-ray spectroscopy (EDS) and atomic force microscopy (AFM) surface analysis techniques were used to investigate the metal oxide dispersions inside polyaniline matrix. Gas sensors were prepared by spin coating solutions of TANIPANI-TiO2 and TANIPANI composites onto glass slides. Sensors were tested at three different concentrations (20 ppm, 40 ppm, and 60 ppm) of ammonia gas at ambient temperature conditions by measuring the changes in surface resistivity of the films with respect to time. Ammonia gas sensing plots are presented showing the response values, response times and recovery times. The TANIPANI-TiO2 composite exhibited better response and shorter recovery times when compared to TANIPANI control and other polyaniline composites that have been reported in the literature. For the first time a proposed mechanism of gas sensing basing on the polaron band localization and its effects on the gas sensing behavior of polyaniline are reported. PMID:26501291

  5. Rapid and simple analysis of disease-associated biomarkers of Taiwanese patients with schizophrenia using matrix-assisted laser desorption ionization mass spectrometry.

    PubMed

    Huang, Tiao-Lai; Lo, Li-Hua; Shiea, Jentaie; Su, Hung

    2017-10-01

    Matrix-assisted laser desorption ionization/time-of-flight mass spectrometry (MALDI-TOF MS) is an extremely sensitive analytical tool for characterizing biological compounds in bio samples. In this study, we applied MALDI-TOF MS to assess potential protein biomarkers in the peripheral blood mononuclear cells (PBMCs) of patients with schizophrenia in the acute phase, recovery phase and healthy controls in Taiwan. We recruited 40 participants, including 20 pairs of patients diagnosed with schizophrenia in the acute phase, after four-week treatment with drug in the recovery phase, and 20 healthy controls. The schizophrenic patients were diagnosed using Structured Clinical Interview for DSM-IV Axis I Disorders (SCID), and severity was assessed by a positive and negative symptom scale at baseline and at endpoint following four-week treatment with drug. The patients' PBMCs biomarkers were rapidly measured using a technique that combines MALDI-TOF MS and principle component analysis. A receiver operating characteristic curve was created for the evaluated biomarker. Significant differences in α-defensins 1-3 were found between the patients in acute phase with schizophrenia and the healthy controls, but not between the schizophrenic patients in recovery phase and healthy controls or between the schizophrenic patients in acute phase and in recovery phase. α-Defensins can be biomarkers of Taiwanese patients with schizophrenia, thus supporting the hypothesis that the inflammatory response and immunity system is correlated with the pathophysiology of schizophrenia. Moreover, the result also implies that α-defensins may be related in schizophrenia-associated disease not in efficacy of drug-treatment. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Routine determination of sulfonylurea, imidazolinone, and sulfonamide herbicides at nanogram-per-liter concentrations by solid-phase extraction and liquid chromatography/mass spectrometry

    USGS Publications Warehouse

    Furlong, E.T.; Burkhardt, M.R.; Gates, Paul M.; Werner, S.L.; Battaglin, W.A.

    2000-01-01

    Sulfonylurea (SU), imidazolinone (IMI), and sulfonamide (SA) herbicides are new classes of low-application-rate herbicides increasingly used by farmers. Some of these herbicides affect both weed and crop species at low dosages and must be carefully used. Less is known about the effect of these compounds on non-crop plant species, but a concentration of 100 ng/l in water has been proposed as the threshold for possible plant toxicity for most of these herbicides. Hence, analytical methods must be capable of detecting SUs, IMIs, and SAs at concentrations less than 100 ng/l in ambient water samples. The authors developed a two-cartridge, solid-phase extraction method for isolating 12 SU, 3 IMI, and 1 SA herbicides by using high-performance liquid chromatography/electrospray ionization-mass spectrometry (HPLC/ESI-MS) to identify and quantify these herbicides to 10 ng/l. This method was used to analyze 196 surface- and ground-water samples collected from May to August 1998 throughout the Midwestern United States, and more than 100 quality-assurance and quality-control samples. During the 16 weeks of the study, the HPLC/ESI-MS maintained excellent calibration linearity across the calibration range from 5 to 500 ng/l, with correlation coefficients of 0.9975 or greater. Continuing calibration verification standards at 100-ng/l concentration were analyzed throughout the study, and the average measured concentrations for individual herbicides ranged from 93 to 100 ng/l. Recovery of herbicides from 27 reagent-water samples spiked at 50 and 100 ng/l ranged from 39 to 92%, and averaged 73%. The standard deviation of recoveries ranged from 14 to 26%, and averaged 20%. This variability reflects multiple instruments, operators, and the use of automated and manual sample preparation. Spiked environmental water samples had similar recoveries, although for some herbicides, the sample matrix enhanced recoveries by as much as 200% greater than the spiked concentration. This matrix enhancement was sample- and compound-dependent. Concentrations of herbicides in unspiked duplicate environmental samples were typically within 25% of each other. The results demonstrate the usefulness of HPLC/ESI-MS for determining low-application-rate herbicides at ambient concentrations. Copyright (C) 2000 Elsevier Science B.V.

  7. Potential sources of analytical bias and error in selected trace element data-quality analyses

    USGS Publications Warehouse

    Paul, Angela P.; Garbarino, John R.; Olsen, Lisa D.; Rosen, Michael R.; Mebane, Christopher A.; Struzeski, Tedmund M.

    2016-09-28

    Potential sources of analytical bias and error associated with laboratory analyses for selected trace elements where concentrations were greater in filtered samples than in paired unfiltered samples were evaluated by U.S. Geological Survey (USGS) Water Quality Specialists in collaboration with the USGS National Water Quality Laboratory (NWQL) and the Branch of Quality Systems (BQS).Causes for trace-element concentrations in filtered samples to exceed those in associated unfiltered samples have been attributed to variability in analytical measurements, analytical bias, sample contamination either in the field or laboratory, and (or) sample-matrix chemistry. These issues have not only been attributed to data generated by the USGS NWQL but have been observed in data generated by other laboratories. This study continues the evaluation of potential analytical bias and error resulting from matrix chemistry and instrument variability by evaluating the performance of seven selected trace elements in paired filtered and unfiltered surface-water and groundwater samples collected from 23 sampling sites of varying chemistries from six States, matrix spike recoveries, and standard reference materials.Filtered and unfiltered samples have been routinely analyzed on separate inductively coupled plasma-mass spectrometry instruments. Unfiltered samples are treated with hydrochloric acid (HCl) during an in-bottle digestion procedure; filtered samples are not routinely treated with HCl as part of the laboratory analytical procedure. To evaluate the influence of HCl on different sample matrices, an aliquot of the filtered samples was treated with HCl. The addition of HCl did little to differentiate the analytical results between filtered samples treated with HCl from those samples left untreated; however, there was a small, but noticeable, decrease in the number of instances where a particular trace-element concentration was greater in a filtered sample than in the associated unfiltered sample for all trace elements except selenium. Accounting for the small dilution effect (2 percent) from the addition of HCl, as required for the in-bottle digestion procedure for unfiltered samples, may be one step toward decreasing the number of instances where trace-element concentrations are greater in filtered samples than in paired unfiltered samples.The laboratory analyses of arsenic, cadmium, lead, and zinc did not appear to be influenced by instrument biases. These trace elements showed similar results on both instruments used to analyze filtered and unfiltered samples. The results for aluminum and molybdenum tended to be higher on the instrument designated to analyze unfiltered samples; the results for selenium tended to be lower. The matrices used to prepare calibration standards were different for the two instruments. The instrument designated for the analysis of unfiltered samples was calibrated using standards prepared in a nitric:hydrochloric acid (HNO3:HCl) matrix. The instrument designated for the analysis of filtered samples was calibrated using standards prepared in a matrix acidified only with HNO3. Matrix chemistry may have influenced the responses of aluminum, molybdenum, and selenium on the two instruments. The best analytical practice is to calibrate instruments using calibration standards prepared in matrices that reasonably match those of the samples being analyzed.Filtered and unfiltered samples were spiked over a range of trace-element concentrations from less than 1 to 58 times ambient concentrations. The greater the magnitude of the trace-element spike concentration relative to the ambient concentration, the greater the likelihood spike recoveries will be within data control guidelines (80–120 percent). Greater variability in spike recoveries occurred when trace elements were spiked at concentrations less than 10 times the ambient concentration. Spike recoveries that were considerably lower than 90 percent often were associated with spiked concentrations substantially lower than what was present in the ambient sample. Because the main purpose of spiking natural water samples with known quantities of a particular analyte is to assess possible matrix effects on analytical results, the results of this study stress the importance of spiking samples at concentrations that are reasonably close to what is expected but sufficiently high to exceed analytical variability. Generally, differences in spike recovery results between paired filtered and unfiltered samples were minimal when samples were analyzed on the same instrument.Analytical results for trace-element concentrations in ambient filtered and unfiltered samples greater than 10 and 40 μg/L, respectively, were within the data-quality objective for precision of ±25 percent. Ambient trace-element concentrations in filtered samples greater than the long-term method detection limits but less than 10 μg/L failed to meet the data-quality objective for precision for at least one trace element in about 54 percent of the samples. Similarly, trace-element concentrations in unfiltered samples greater than the long-term method detection limits but less than 40 μg/L failed to meet this data-quality objective for at least one trace-element analysis in about 58 percent of the samples. Although, aluminum and zinc were particularly problematic, limited re-analyses of filtered and unfiltered samples appeared to improve otherwise failed analytical precision.The evaluation of analytical bias using standard reference materials indicate a slight low bias for results for arsenic, cadmium, selenium, and zinc. Aluminum and molybdenum show signs of high bias. There was no observed bias, as determined using the standard reference materials, during the analysis of lead.

  8. Investigation of the Self-Healing Behavior of Sn-Bi Metal Matrix Composite Reinforced with NiTi Shape Memory Alloy Strips Under Flexural Loading

    NASA Astrophysics Data System (ADS)

    Poormir, Mohammad Amin; Khalili, Seyed Mohammad Reza; Eslami-Farsani, Reza

    2018-03-01

    Utilizing intelligent materials such as shape memory alloys as reinforcement in metal matrix composites is a novel method to mimic self-healing behavior. In this study, the bending behavior of a self-healing metal matrix composite made from Sn-13 wt.% Bi alloy as matrix and NiTi shape memory alloy (SMA) strips as reinforcement is investigated. Specimens were fabricated in different reinforcement vol.% (0.78, 1.55, 2.33) and in various pre-strains (0, 2, 6%) and were healed at three healing temperatures (170°C, 180°C, 190°C). Results showed that shape recovery was accomplished in all the specimens, but not all of them were able to withstand second loading after healing. Only specimens with 2.33 vol.% of SMA strips, 1.55 vol.% of SMA, and 6% pre-strain could endure bending force after healing, and they gained 35.31-51.83% of bending force self-healing efficiency.

  9. Investigation of the Self-Healing Behavior of Sn-Bi Metal Matrix Composite Reinforced with NiTi Shape Memory Alloy Strips Under Flexural Loading

    NASA Astrophysics Data System (ADS)

    Poormir, Mohammad Amin; Khalili, Seyed Mohammad Reza; Eslami-Farsani, Reza

    2018-06-01

    Utilizing intelligent materials such as shape memory alloys as reinforcement in metal matrix composites is a novel method to mimic self-healing behavior. In this study, the bending behavior of a self-healing metal matrix composite made from Sn-13 wt.% Bi alloy as matrix and NiTi shape memory alloy (SMA) strips as reinforcement is investigated. Specimens were fabricated in different reinforcement vol.% (0.78, 1.55, 2.33) and in various pre-strains (0, 2, 6%) and were healed at three healing temperatures (170°C, 180°C, 190°C). Results showed that shape recovery was accomplished in all the specimens, but not all of them were able to withstand second loading after healing. Only specimens with 2.33 vol.% of SMA strips, 1.55 vol.% of SMA, and 6% pre-strain could endure bending force after healing, and they gained 35.31-51.83% of bending force self-healing efficiency.

  10. On-Plate Self-Desalting and Matrix-Free LDI MS Analysis of Peptides With a Surface Patterned Sample Support

    NASA Astrophysics Data System (ADS)

    Zeng, Zhoufang; Wang, Yandong; Guo, Xinhua; Wang, Ling; Lu, Nan

    2014-05-01

    A hydrophobic-hydrophilic-hydrophobic pattern has been produced on the surface of a silicon substrate for selective enrichment, self-desalting, and matrix-free analysis of peptides in a single step. Upon sample application, the sample solution is first confined in a small area by a hydrophobic F-SAM outer area, after which salt contaminants and peptides are selectively enriched in the hydrophilic and hydrophobic areas, respectively. Simultaneously, matrix background noise is significantly reduced or eliminated because of immobilization of matrix molecules. As a result, the detection sensitivity is enhanced 20-fold compared with that obtained using the usual MALDI plate, and interference-free detection is achieved in the low m/z range. In addition, peptide ions can be identified unambiguously in the presence of NH4HCO3 (100 mM), urea (1 M), and NaCl (1 M). When the device was applied to the analysis of BSA digests, the peptide recovery and protein identification confidence were greatly improved.

  11. Onion skin waste as a valorization resource for the by-products quercetin and biosugar.

    PubMed

    Choi, In Seong; Cho, Eun Jin; Moon, Jae-Hak; Bae, Hyeun-Jong

    2015-12-01

    Onion skin waste (OSW), which is produced from processed onions, is a major industrial waste. We evaluated the use of OSW for biosugar and quercetin production. The carbohydrate content of OSW was analyzed, and the optimal conversion conditions were evaluated by varying enzyme mixtures and loading volumes for biosugar production and quercetin extraction. The enzymatic conversion rate of OSW to biosugar was 98.5% at 0.72 mg of cellulase, 0.16 mg of pectinase, and 1.0mg of xylanase per gram of dry OSW. Quercetin extraction also increased by 1.61-fold after complete enzymatic hydrolysis. In addition, the newly developed nano-matrix (terpyridine-immobilized silica-coated magnetic nanoparticles-zinc (TSMNP-Zn matrix) was utilized to separate quercetin from OSW extracts. The nano-matrix facilitated easy separation and purification of quercetin. Using the TSMNP-Zn matrix the quercetin was approximately 90% absorbed. In addition, the recovery yield of quercetin was approximately 75% after treatment with ethylenediaminetetraacetic acid. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Matrix Metalloproteinases as a Therapeutic Target to Improve Neurologic Recovery after Spinal Cord Injury

    DTIC Science & Technology

    2012-10-01

    pressure (maximal vesical pressure in an animal without voluntary voiding, prior to urine overflow), voiding duration, and voiding interval (the frequency...until euthanasia . Neurological status was evaluated at 1 and 3 days post injury and weekly thereafter for 3 weeks. At 4 weeks post-injury, awake

  13. Contractile recovery of microtissues after giant shear events

    NASA Astrophysics Data System (ADS)

    Morley, Cameron; Bhattacharjee, Tapomoy; Ellison, Sarah; Sawyer, W.; Angelini, Thomas

    Cells are often dispersed in extracellular matrix (ECM) gels like collagen and Matrigel as minimal tissue models. Generally, large-scale contraction of these constructs is observed, in which the degree of contraction of the entire system correlates with cell density and ECM concentration. The freedom to perform diverse mechanical experiments on these contracting constructs is limited by the challenges of handling and supporting these delicate samples. Here, we present a method to create simple cell-ECM constructs that can be manipulated with significantly reduced experimental limitations. We 3D print mixtures of MCF10A cells and ECM (collagen-I and Matrigel) into a 3D growth medium made from jammed microgels. With this approach, we are able to apply shear stresses to the cell constructs times after printing and observe the collective response. Preliminary results reveal that, following shear deformations that exceed 300% and dramatically smear cells and matrix in space, the cells actively re-contract the construct toward the un-sheared construct. These results suggest that new principles of collective recovery can be employed for tissue engineering applications using jammed microgels as a re-configurable support medium.

  14. Analysis of chlorothalonil and three degradates in sediment and soil

    USGS Publications Warehouse

    Hladik, M.L.; Kuivila, K.M.

    2008-01-01

    A method has been developed for the simultaneous extraction of chlorothalonil and three of its degradates (4-hydroxy-2,5,6- trichloroisophthalonitrile, 1-carbamoyl-3-cyano-4-hydroxy-2,5,6- trichlorobenzene, and 1,3-dicarbamoyl-2,4,5,6-tetrachlorobenzene) from soils and sediments; the compounds were extracted using sonication with acetone and isolation of the parent compound and matrix interferences from the degradates by solid phase extraction (SPE). The chlorothalonil fraction underwent further coextracted matrix interference removal with Florisil. The degradates were derivatized with N,O-bis(trimethylsilyl) trifluoroacetamide (BSTFA) and chlorotrimethylsilane (TMCS). All compounds were analyzed by gas chromatography-mass spectrometry (GC-MS). Recoveries on a spiked (20 and 200 ??g kg-1) sediment ranged from 80% to 91% with calculated limits of detection of 1-5 ??g kg-1 dry weight sediment. An additional 20 sediment samples were collected in watersheds from the Southeastern United States where chlorothalonil is used widely on peanuts and other crops. None of the target compounds were detected. Laboratory fortified recoveries of chlorothalonil and its degradates in these environmental sediment samples ranged from 75% to 89%.

  15. Exact recovery of sparse multiple measurement vectors by [Formula: see text]-minimization.

    PubMed

    Wang, Changlong; Peng, Jigen

    2018-01-01

    The joint sparse recovery problem is a generalization of the single measurement vector problem widely studied in compressed sensing. It aims to recover a set of jointly sparse vectors, i.e., those that have nonzero entries concentrated at a common location. Meanwhile [Formula: see text]-minimization subject to matrixes is widely used in a large number of algorithms designed for this problem, i.e., [Formula: see text]-minimization [Formula: see text] Therefore the main contribution in this paper is two theoretical results about this technique. The first one is proving that in every multiple system of linear equations there exists a constant [Formula: see text] such that the original unique sparse solution also can be recovered from a minimization in [Formula: see text] quasi-norm subject to matrixes whenever [Formula: see text]. The other one is showing an analytic expression of such [Formula: see text]. Finally, we display the results of one example to confirm the validity of our conclusions, and we use some numerical experiments to show that we increase the efficiency of these algorithms designed for [Formula: see text]-minimization by using our results.

  16. Stealthy false data injection attacks using matrix recovery and independent component analysis in smart grid

    NASA Astrophysics Data System (ADS)

    JiWei, Tian; BuHong, Wang; FuTe, Shang; Shuaiqi, Liu

    2017-05-01

    Exact state estimation is vital important to maintain common operations of smart grids. Existing researches demonstrate that state estimation output could be compromised by malicious attacks. However, to construct the attack vectors, a usual presumption in most works is that the attacker has perfect information regarding the topology and so on even such information is difficult to acquire in practice. Recent research shows that Independent Component Analysis (ICA) can be used for inferring topology information which can be used to originate undetectable attacks and even to alter the price of electricity for the profits of attackers. However, we found that the above ICA-based blind attack tactics is merely feasible in the environment with Gaussian noises. If there are outliers (device malfunction and communication errors), the Bad Data Detector will easily detect the attack. Hence, we propose a robust ICA based blind attack strategy that one can use matrix recovery to circumvent the outlier problem and construct stealthy attack vectors. The proposed attack strategies are tested with IEEE representative 14-bus system. Simulations verify the feasibility of the proposed method.

  17. Evaluation of stir-bar sorptive extraction coupled with thermal desorption GC-MS for the detection of leachables from polymer single use systems to drugs.

    PubMed

    Scherer, Nicole; Marcseková, Klaudia; Posset, Tobias; Winter, Gerhard

    2018-04-15

    Stir-bar Sorptive Extraction (SBSE) in combination with thermal desorption and gas chromatography-mass spectrometry (TD-GC-MS) is widely accepted as the gold-standard analysis method for trace amounts of organic substances, including leachables in aqueous matrices. Meanwhile, as far as pharmaceutical quality control in protein-based parenteral drugs is concerned, the use of SBSE analysis remains unexplored. Previous studies reported a strong influence of the matrix on the method's recovery. The scope of the present work was to fill in the unexplored territory in a threefold manner 1) by quantifying the effects that various matrices commonly found in pharmaceutical processing have on the recovery, 2) by comparing between different coating materials for stir bar (namely between polydimethylsiloxane (PDMS) material and ethylene-glycol (EG)-PDMS), and 3) by proposing a preparation step for stir-bar to mitigate inhibitory effects. The current study shows no inhibition of SBSE by protein matrices (p > 0.15). Further the influence of various drug matrices on the recovery of leachables with a log K o/w  ≥ 3.6 is negligible (-3.9 to 3.8%). In contrast, the inhibition effect caused by an alkaline media led to a recovery decrease of -42.9%. For leachables with a log K o/w  < 3.6, the relative recovery in the presence of various proteins ranged from -72.8% to 15.6%, depending on the excipients of the drug product and not on the protein itself. The highest loss in sensitivity was observed when the excipient benzyl alcohol was present in the drug. Nonetheless, the limit of detection for the tested leachables in the inhibitory matrices was still below 3 μg/L (ppb). Additionally, SBSE was observed to be quantitatively reliable in all tested drug matrices for concentrations from 0.005 to 0.1 mg/mL (r 2  > 0.992). On average, the conventional PDMS coating resulted in a 28-fold higher signal-to-noise ratio compared to EG-PDMS. Furthermore, a broader range of leachables was detectable with the PDSM coating. Preceding stir-bar preparation consisting of a simple soaking step improved the enrichment by 14%, effectively lowering the limit of detection. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Multi-stage classification method oriented to aerial image based on low-rank recovery and multi-feature fusion sparse representation.

    PubMed

    Ma, Xu; Cheng, Yongmei; Hao, Shuai

    2016-12-10

    Automatic classification of terrain surfaces from an aerial image is essential for an autonomous unmanned aerial vehicle (UAV) landing at an unprepared site by using vision. Diverse terrain surfaces may show similar spectral properties due to the illumination and noise that easily cause poor classification performance. To address this issue, a multi-stage classification algorithm based on low-rank recovery and multi-feature fusion sparse representation is proposed. First, color moments and Gabor texture feature are extracted from training data and stacked as column vectors of a dictionary. Then we perform low-rank matrix recovery for the dictionary by using augmented Lagrange multipliers and construct a multi-stage terrain classifier. Experimental results on an aerial map database that we prepared verify the classification accuracy and robustness of the proposed method.

  19. Translating effects of inbreeding depression on component vital rates to overall population growth in endangered bighorn sheep.

    PubMed

    Johnson, Heather E; Mills, L Scott; Wehausen, John D; Stephenson, Thomas R; Luikart, Gordon

    2011-12-01

    Evidence of inbreeding depression is commonly detected from the fitness traits of animals, yet its effects on population growth rates of endangered species are rarely assessed. We examined whether inbreeding depression was affecting Sierra Nevada bighorn sheep (Ovis canadensis sierrae), a subspecies listed as endangered under the U.S. Endangered Species Act. Our objectives were to characterize genetic variation in this subspecies; test whether inbreeding depression affects bighorn sheep vital rates (adult survival and female fecundity); evaluate whether inbreeding depression may limit subspecies recovery; and examine the potential for genetic management to increase population growth rates. Genetic variation in 4 populations of Sierra Nevada bighorn sheep was among the lowest reported for any wild bighorn sheep population, and our results suggest that inbreeding depression has reduced adult female fecundity. Despite this population sizes and growth rates predicted from matrix-based projection models demonstrated that inbreeding depression would not substantially inhibit the recovery of Sierra Nevada bighorn sheep populations in the next approximately 8 bighorn sheep generations (48 years). Furthermore, simulations of genetic rescue within the subspecies did not suggest that such activities would appreciably increase population sizes or growth rates during the period we modeled (10 bighorn sheep generations, 60 years). Only simulations that augmented the Mono Basin population with genetic variation from other subspecies, which is not currently a management option, predicted significant increases in population size. Although we recommend that recovery activities should minimize future losses of genetic variation, genetic effects within these endangered populations-either negative (inbreeding depression) or positive (within subspecies genetic rescue)-appear unlikely to dramatically compromise or stimulate short-term conservation efforts. The distinction between detecting the effects of inbreeding depression on a component vital rate (e.g., fecundity) and the effects of inbreeding depression on population growth underscores the importance of quantifying inbreeding costs relative to population dynamics to effectively manage endangered populations. ©2011 Society for Conservation Biology.

  20. The influence of visible light on transparent zinc tin oxide thin film transistors

    NASA Astrophysics Data System (ADS)

    Görrn, P.; Lehnhardt, M.; Riedl, T.; Kowalsky, W.

    2007-11-01

    The characteristics of transparent zinc tin oxide thin film transistors (TTFTs) upon illumination with visible light are reported. Generally, a reversible decrease of threshold voltage Vth, saturation field effect mobility μsat, and an increase of the off current are found. The time scale of the recovery in the dark is governed by the persistent photoconductivity in the semiconductor. Devices with tuned [Zn]:[Sn] ratio show a shift of Vth of less 2V upon illumination at 5mW/cm2 (brightness >30000cd/m2) throughout the visible spectrum. These results demonstrate TTFTs which are candidates as pixel drivers in transparent active-matrix organic light emitting diode displays.

  1. Microstructure and Shape Memory Behavior of Ti-Nb Shape Memory Alloy Thin Film

    NASA Astrophysics Data System (ADS)

    Meng, X. L.; Sun, B.; Sun, J. Y.; Gao, Z. Y.; Cai, W.; Zhao, L. C.

    2017-09-01

    Ti-Nb shape memory alloy (SMA) thin film is a promising candidate applied as microactuator in biomedical field. In this study, the microstructure and shape memory behavior of Ti-Nb SMA thin films in different heat treatment conditions have been investigated. Fine ω phases embedded in the β phase matrix suppress the martensitic transformation of the films. As a result, the as-deposited and most of the annealed films consist of the β and α″ dual phases. The annealed Ti-Nb thin film shows excellent superelasticity effect when deformed above the reverse martensitic transformation temperature, that is 3.5% total recovery strain can be obtained when 4% pre-strain is loaded.

  2. Inhibition of transforming growth factor-β attenuates brain injury and neurological deficits in a rat model of germinal matrix hemorrhage.

    PubMed

    Manaenko, Anatol; Lekic, Tim; Barnhart, Margaret; Hartman, Richard; Zhang, John H

    2014-03-01

    Transforming growth factor-β (TGF-β) overproduction and activation of the TGF-β pathway are associated with the development of brain injury following germinal matrix hemorrhage (GMH) in premature infants. We examined the effects of GMH on the level of TGF-β1 in a novel rat collagenase-induced GMH model and determined the effect of inhibition of the TGF receptor I. In total, 92 seven-day old (P7) rats were used. Time-dependent effects of GMH on the level of TGF-β1 and TGF receptor I were evaluated by Western blot. A TGF receptor I inhibitor (SD208) was administered daily for 3 days, starting either 1 hour or 3 days after GMH induction. The effects of GMH and SD208 on the TGF-β pathway were evaluated by Western blot at day 3. The effects of GMH and SD208 on cognitive and motor function were also assessed. The effects of TGF receptor I inhibition by SD208 on GMH-induced brain injury and underlying molecular pathways were investigated by Western blot, immunofluorescence, and morphology studies 24 days after GMH. GMH induced significant delay in development, caused impairment in both cognitive and motor functions, and resulted in brain atrophy in rat subjects. GMH also caused deposition of both vitronectin (an extracellular matrix protein) and glial fibrillary acidic protein in perilesion areas, associated with development of hydrocephalus. SD208 ameliorated GMH-induced developmental delay, improved cognitive and motor functions, and attenuated body weight loss. SD208 also decreased vitronectin and glial fibrillary acidic protein deposition and decreased GMH-induced brain injury. Increased level of TGF-β1 and activation of the TGF-β pathway associate with the development of brain injury after GMH. SD208 inhibits GMH-induced activation of the TGF-β pathway and leads to an improved developmental profile, partial recovery of cognitive and motor functions, and attenuation of GMH-induced brain atrophy and hydrocephalus.

  3. Recovery of microtubules on the blepharoplast of Ceratopteris spermatogenous cells after oryzalin treatment.

    PubMed

    Vaughn, Kevin C; Bowling, Andrew J

    2008-11-01

    Most land plants have ill-defined microtubule-organizing centers (MTOCs), consisting of sites on the nuclear envelope or even along microtubules (MTs). In contrast, the spermatogenous cells of the pteridophyte Ceratopteris richardii have a well-defined MTOC, the blepharoplast, which organizes MTs through the last two division cycles. This allows a rare opportunity to study the organization and workings of a structurally well-defined plant MTOC. In this study, antheridial plants were treated with levels of oryzalin that cause complete MT loss from the cells containing blepharoplasts. The oryzalin was then washed out and plants were allowed to recover for varying amounts of time. If the spermatogenous cells were fixed prior to washing out, the blepharoplasts had an unusual appearance. In the matrix (pericentriolar) material where MT ends are normally found, clear areas of about the diameter of MTs were seen embedded in a much deeper matrix, made more obvious in stereo pairs. Occasionally, the matrix material was highly distended, although the basal body template cylinder morphology appeared to be unaltered. The blepharoplasts often occurred as clusters of 2 or 4, indicating that blepharoplast reproduction is not affected by the lack of MTs, but that their movement to the poles is. Gamma (gamma) tubulin antibodies labeled the edge of the blepharoplast in areas where the pits are located, indicating that these might be sites for MT nucleation. After wash out, the new MTs always re-appeared on the blepharoplast and the recovery occurred within an hour of washout. MT lengths increased with increasing washout time and were indistinguishable from untreated blepharoplasts after 24 h of recovery. After washout, arrays formed in new sperm cells such as the spline and basal bodies were often malformed or present in multiple copies, as were the blepharoplasts in these cells prior to wash out. These data indicate that the blepharoplast serves as the site of MT nucleation and organization even after complete MT de-polymerization.

  4. Cobalt as chemical modifier to improve chromium sensitivity and minimize matrix effects in tungsten coil atomic emission spectrometry.

    PubMed

    Silva, Sidnei G; Donati, George L; Santos, Luana N; Jones, Bradley T; Nóbrega, Joaquim A

    2013-05-30

    Cobalt is used as chemical modifier to improve sensitivity and minimize matrix effects in Cr determinations by tungsten coil atomic emission spectrometry (WCAES). The atomizer is a tungsten filament extracted from microscope light bulbs. A solid-state power supply and a handheld CCD-based spectrometer are also used in the instrumental setup. In the presence of 1000 mg L(-1) Co, WCAES limit of detection for Cr (λ=425.4 nm) is calculated as 0.070 mg L(-1); a 10-fold improvement compared to determinations without Co modifier. The mechanism involved in such signal enhancement is similar to the one observed in ICP OES and ICP-MS determinations of As and Se in the presence of C. Cobalt increases the population of Cr(+) by charge transfer reactions. In a second step, Cr(+)/e(-) recombination takes place, which results in a larger population of excited-state Cr atoms. This alternative excitation route is energetically more efficient than heat transfer from atomizer and gas phase to analyte atoms. A linear dynamic range of 0.25-10 mg L(-1) and repeatability of 3.8% (RSD, n=10) for a 2.0 mg L(-1) Cr solution are obtained with this strategy. The modifier high concentration also contributes to improving accuracy due to a matrix-matching effect. The method was applied to a certified reference material of Dogfish Muscle (DORM-2) and no statistically significant difference was observed between determined and certified Cr values at a 95% confidence level. Spike experiments with bottled water samples resulted in recoveries between 93% and 112%. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Metal recovery from porous materials

    DOEpatents

    Sturcken, Edward F.

    1992-01-01

    A method for recovering plutonium and other metals from materials by leaching comprising the steps of incinerating the materials to form a porous matrix as the residue of incineration, immersing the matrix into acid in a microwave-transparent pressure vessel, sealing the pressure vessel, and applying microwaves so that the temperature and the pressure in the pressure vessel increase. The acid for recovering plutonium can be a mixture of HBF.sub.4 and HNO.sub.3 and preferably the pressure is increased to at least 100 PSI and the temperature to at least 200.degree. C. The porous material can be pulverized before immersion to further increase the leach rate.

  6. Metal recovery from porous materials

    DOEpatents

    Sturcken, E.F.

    1992-10-13

    A method is described for recovering plutonium and other metals from materials by leaching comprising the steps of incinerating the materials to form a porous matrix as the residue of incineration, immersing the matrix into acid in a microwave-transparent pressure vessel, sealing the pressure vessel, and applying microwaves so that the temperature and the pressure in the pressure vessel increase. The acid for recovering plutonium can be a mixture of HBF[sub 4] and HNO[sub 3] and preferably the pressure is increased to at least 100 PSI and the temperature to at least 200 C. The porous material can be pulverized before immersion to further increase the leach rate.

  7. Regenerator matrix physical property data

    NASA Technical Reports Server (NTRS)

    Fucinari, C. A.

    1980-01-01

    Among several cellular ceramic structures manufactured by various suppliers for regenerator application in a gas turbine engine, three have the best potential for achieving durability and performance objectives for use in gas turbines, Stirling engines, and waste heat recovery systems: (1) an aluminum-silicate sinusoidal flow passage made from a corrugated wate paper process; (2) an extruded isosceles triangle flow passage; and (3) a second generation matrix incorporating a square flow passage formed by an embossing process. Key physical and thermal property data for these configurations presented include: heat transfer and pressure drop characteristics, compressive strength, tensile strength and elasticity, thermal expansion characteristics, chanical attack, and thermal stability.

  8. Refined methodology for the determination of neonicotinoid pesticides and their metabolites in honey bees and bee products by liquid chromatography-tandem mass spectrometry (LC-MS/MS).

    PubMed

    Kamel, Alaa

    2010-05-26

    An analytical method was refined for the extraction and determination of neonicotinoid pesticide residues and their metabolites in honey bees and bee products. Samples were extracted with 2% triethylamine (TEA) in acetonitrile (ACN) followed by salting out, solid phase extraction (SPE) cleanup, and detection using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The method was validated in triplicate at three fortification concentrations in each matrix. Good recoveries were observed for most analytes and ranged between 70 and 120% with relative standard deviations between replicates of <20% in most cases. The method limits of detection were 0.2 ng/g for the parent neonicotinoid pesticides and ranged between 0.2 and 15 ng/g for the neonicotinoid metabolites. This refined method provides lower detection limits and improved recovery of neonicotinoids and their metabolites, which will help researchers evaluate subchronic effects of these pesticides, address data gaps related to colony collapse disorder (CCD), and determine the role of pesticides in pollinator decline.

  9. Speciation of Mn(II), Mn(VII) and total manganese in water and food samples by coprecipitation-atomic absorption spectrometry combination.

    PubMed

    Citak, Demirhan; Tuzen, Mustafa; Soylak, Mustafa

    2010-01-15

    A speciation procedure based on the coprecipitation of manganese(II) with zirconium(IV) hydroxide has been developed for the investigation of levels of manganese species. The determination of manganese levels was performed by flame atomic absorption spectrometry (FAAS). Total manganese was determined after the reduction of Mn(VII) to Mn(II) by ascorbic acid. The analytical parameters including pH, amount of zirconium(IV), sample volume, etc., were investigated for the quantitative recoveries of manganese(II). The effects of matrix ions were also examined. The recoveries for manganese(II) were in the range of 95-98%. Preconcentration factor was calculated as 50. The detection limit for the analyte ions based on 3 sigma (n=21) was 0.75 microg L(-1) for Mn(II). The relative standard deviation was found to be lower than 7%. The validation of the presented procedure was performed by analysis of certified reference material having different matrices, NIST SRM 1515 (Apple Leaves) and NIST SRM 1568a (Rice Flour). The procedure was successfully applied to natural waters and food samples.

  10. Removal of sudan dyes from water with C18-functional ultrafine magnetic silica nanoparticles.

    PubMed

    Jiang, Chunzhu; Sun, Ying; Yu, Xi; Zhang, Lei; Sun, Xiumin; Gao, Yan; Zhang, Hanqi; Song, Daqian

    2012-01-30

    In this study, the new C(18)-functionalized ultrafine magnetic silica nanoparticles (C(18)-UMS NPs) were successfully synthesized and applied for extraction of sudan dyes in water samples based on the magnetic solid-phase extraction (MSPE). The extraction and concentration were carried out in one step by blending C(18)-UMS NPs and water samples. The sudan dyes adsorbed C(18)-UMS NPs were isolated from the matrix easily with an external magnetic field. After desorption the quantitation of sudan dyes was done by ultra fast liquid chromatography (UFLC). Satisfactory extraction recovery can be obtained with only 50 mg C(18)-UMS NPs. The effects of experimental parameters, including the amount of the nanoparticles, extraction time, pH value, desorption solvent, volume of desorption solvent and desorption time were investigated. The limits of detection for sudan I, II, III and IV were 0.066, 0.070, 0.12 and 0.12 ng mL(-1), respectively. Recoveries obtained by analyzing the six spiked water samples were between 68% and 103%. Copyright © 2011 Elsevier B.V. All rights reserved.

  11. Single-hole hollow molecularly imprinted polymer embedded carbon dot for fast detection of tetracycline in honey.

    PubMed

    Li, Huiyu; Zhao, Li; Xu, Yuan; Zhou, Tianyu; Liu, Haochi; Huang, Ning; Ding, Jie; Li, Yi; Ding, Lan

    2018-08-01

    It is difficult to detect tetracycline (TC) in honey sample by using carbon dots (CDs) because the autofluorescence of the matrix of honey sample overlaps with the fluorescence emission spectrum of the large majority of CDs. Herein, single-hole hollow molecularly imprinted polymers embedded carbon dots (HMIP@CD) was prepared via microwave-assisted method. TC in diluted honey sample was adsorbed by the HMIP@CD within 3 min, after which the HMIP@CD absorbed with TC was separated by centrifugation from honey sample and redispersed into phosphate buffer solution. The autofluorescence of honey that interferes with the fluorescence signal of HMIP@CD was avoided. The method exhibited an excellent linearity within 10-200 μg L -1 and a low detection limit of 3.1 μg L -1 . At three spiking levels of TC, the recoveries ranged from 93% to 105% with precisions below 1.6%. This method provides an effective strategy for detecting analyte in complex matrix with autofluorescence interference. Copyright © 2018. Published by Elsevier B.V.

  12. Simultaneous LC-MS/MS determination of 40 legal and illegal psychoactive drugs in breast and bovine milk.

    PubMed

    López-García, Ester; Mastroianni, Nicola; Postigo, Cristina; Valcárcel, Yolanda; González-Alonso, Silvia; Barceló, Damia; López de Alda, Miren

    2018-04-15

    This work presents a fast, sensitive and reliable multi-residue methodology based on fat and protein precipitation and liquid chromatography-tandem mass spectrometry for the determination of common legal and illegal psychoactive drugs, and major metabolites, in breast milk. One-fourth of the 40 target analytes is investigated for the first time in this biological matrix. The method was validated in breast milk and also in various types of bovine milk, as tranquilizers are occasionally administered to food-producing animals. Absolute recoveries were satisfactory for 75% of the target analytes. The use of isotopically labeled compounds assisted in correcting analyte losses due to ionization suppression matrix effects (higher in whole milk than in the other investigated milk matrices) and ensured the reliability of the results. Average method limits of quantification ranged between 0.4 and 6.8 ng/mL. Application of the developed method showed the presence of caffeine in breast milk samples (12-179 ng/mL). Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. External Standards or Standard Addition? Selecting and Validating a Method of Standardization

    NASA Astrophysics Data System (ADS)

    Harvey, David T.

    2002-05-01

    A common feature of many problem-based laboratories in analytical chemistry is a lengthy independent project involving the analysis of "real-world" samples. Students research the literature, adapting and developing a method suitable for their analyte, sample matrix, and problem scenario. Because these projects encompass the complete analytical process, students must consider issues such as obtaining a representative sample, selecting a method of analysis, developing a suitable standardization, validating results, and implementing appropriate quality assessment/quality control practices. Most textbooks and monographs suitable for an undergraduate course in analytical chemistry, however, provide only limited coverage of these important topics. The need for short laboratory experiments emphasizing important facets of method development, such as selecting a method of standardization, is evident. The experiment reported here, which is suitable for an introductory course in analytical chemistry, illustrates the importance of matrix effects when selecting a method of standardization. Students also learn how a spike recovery is used to validate an analytical method, and obtain a practical experience in the difference between performing an external standardization and a standard addition.

  14. Validated LC-MS-MS Method for Multiresidual Analysis of 13 Illicit Phenethylamines in Amniotic Fluid.

    PubMed

    Burrai, Lucia; Nieddu, Maria; Carta, Antonio; Trignano, Claudia; Sanna, Raimonda; Boatto, Gianpiero

    2016-04-01

    A multi-residue analytical method was developed for the determination in amniotic fluid (AF) of 13 illicit phenethylamines, including 12 compounds never investigated in this matrix before. Samples were subject to solid-phase extraction using; hydrophilic-lipophilic balance cartridges which gave good recoveries and low matrix effects on analysis of the extracts. The quantification was performed by liquid chromatography electrospray tandem mass spectrometry. The water-acetonitrile mobile phase containing 0.1% formic acid, used with a C18 reversed phase column, provided adequate separation, resolution and signal-to-noise ratio for the analytes and the internal standard. The final optimized method was validated according to international guidelines. A monitoring campaign to assess fetal exposure to these 13 substances of abuse has been performed on AF test samples obtained from pregnant women. All mothers (n = 194) reported no use of drugs of abuse during pregnancy, and this was confirmed by the analytical data. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  15. Optimization of two-dimensional gas chromatography time-of-flight mass spectrometry for separation and estimation of the residues of 160 pesticides and 25 persistent organic pollutants in grape and wine.

    PubMed

    Dasgupta, Soma; Banerjee, Kaushik; Patil, Sangram H; Ghaste, Manoj; Dhumal, K N; Adsule, Pandurang G

    2010-06-11

    Two-dimensional gas chromatography (GCxGC) coupled with time-of-flight mass spectrometric (TOFMS) method was optimized for simultaneous analysis of 160 pesticides, 12 dioxin-like polychlorinated biphenyls (PCBs), 12 polyaromatic hydrocarbons (PAHs) and bisphenol A in grape and wine. GCxGC-TOFMS could separate all the 185 analytes within 38min with >85% NIST library-based mass spectral confirmations. The matrix effect quantified as the ratio of the slope of matrix-matched to solvent calibrations was within 0.5-1.5 for most analytes. LOQ of most of the analytes was < or =10microg/L with nine exceptions having LOQs of 12.5-25microg/L. Recoveries ranged between 70 and 120% with <20% expanded uncertainties for 151 and 148 compounds in grape and wine, respectively, with intra-laboratory Horwitz ratio <0.2 for all analytes. The method was evaluated in the incurred grape samples where residues of cypermethrin, permethrin, chlorpyriphos, metalaxyl and etophenprox were detected at below MRL. Copyright 2010 Elsevier B.V. All rights reserved.

  16. Multi-pesticides residue analysis of grains using modified magnetic nanoparticle adsorbent for facile and efficient cleanup.

    PubMed

    Liu, Zhenzhen; Qi, Peipei; Wang, Xiangyun; Wang, Zhiwei; Xu, Xiahong; Chen, Wenxue; Wu, Liyu; Zhang, Hu; Wang, Qiang; Wang, Xinquan

    2017-09-01

    A facile, rapid sample pretreatment method was developed based on magnetic nanoparticles for multi-pesticides residue analysis of grains. Magnetite (Fe 3 O 4 ) nanoparticles modified with 3-(N,N-diethylamino)propyltrimethoxysilane (Fe 3 O 4 -PSA) and commercial C18 were selected as the cleanup adsorbents to remove the target interferences of the matrix, such as fatty acids and non-polar compounds. Rice was used as the representative grain sample for method optimization. The amount of Fe 3 O 4 -PSA and C18 were systematically investigated for selecting the suitable purification conditions, and the simultaneous determination of 50 pesticides and 8 related metabolites in rice was established by liquid chromatography-tandem mass spectrometry. Under the optimal conditions, the method validation was performed including linearity, sensitivity, matrix effect, recovery and precision, which all satisfy the requirement for pesticides residue analysis. Compared to the conventional QuEChERS method with non-magnetic material as cleanup adsorbent, the present method can save 30% of the pretreatment time, giving the high throughput analysis possible. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Isolation and functional studies of human fetal gastric epithelium in primary culture.

    PubMed

    Chailler, Pierre; Beaulieu, Jean-François; Ménard, Daniel

    2012-01-01

    Our understanding of gastric epithelial physiology in man is limited by the absence of normal or appropriate cancer cell lines that could serve as an in vitro model. Research mostly relied on primary culture of gastric epithelial cells of animal species, enriched with surface mucous cells, and devoid of glandular zymogenic chief cells. We successfully applied a new nonenzymatic procedure using Matrisperse Cell Recovery Solution to dissociate the entire epithelium from human fetal stomach. Cultures were generated by seeding multicellular aggregates prepared by mechanical fragmentation. We further demonstrate that this simple and convenient technique allows for the maintenance of heterogenous gastric epithelial primary cultures on plastic without a biological matrix as well as the persistence of viable chief cells able to synthesize and secrete gastric digestive enzymes, i.e., pepsinogen and gastric lipase. In wounding experiments, epithelial restitution occurred in serum-reduced conditions and was modulated by exogenous agents. This culture system is thus representative of the foveolus-gland axis and offers new perspectives to establish the influence of individual growth factors and extracellular matrix components as well as their combinatory effects on gastric epithelium homeostasis.

  18. Study of the versatility of a graphite furnace atomic absorption spectrometric method for the determination of cadmium in the environmental field.

    PubMed

    Rucandio, M Isabel; Petit-Domínguez, M Dolores

    2002-01-01

    Cadmium is a representative example of trace elements that are insidious and widespread health hazards. In contemporary environmental analysis, there is a clear trend toward its determination over a wide range of concentrations in complex matrixes. This paper describes a versatile method for the determination of Cd at various levels (0.1-500 microg/g) in several sample types, such as soils, sediments, coals, ashes, sewage sludges, animal tissues, and plants, by graphite furnace atomic absorption spectrometry with Zeeman background correction. The effect of the individual presence of about 50 elements, with an interference/analyte concentration ratio of up to 10(5), was tested; recoveries of Cd ranged from 93 to 106%. The influence of different media, such as HNO3, HCI, HF, H2SO4, HClO4, acetic acid, hydroxylammonium chloride, and ammonium acetate, in several concentrations, was also tested. From these studies it can be concluded that the analytical procedure is scarcely matrix dependent, and the results obtained for a wide diversity of reference materials are in good agreement with the certified values.

  19. Environmentally friendly procedure based on VA-MSPD for the determination of booster biocides in fish tissue.

    PubMed

    Vieira, Augusto A; Caldas, Sergiane S; Escarrone, Ana Laura Venquiaruti; Arias, Jean Lucas de Oliveira; Primel, Ednei Gilberto

    2018-03-01

    Booster biocides have been widely applied to ships and other submerged structures. These compounds can be released into the marine environment as the result of vessel hull leaching and may remain in different environmental compartments. This study aimed at introducing an environmentally friendly procedure for the extraction of irgarol and diuron from fish samples by vortex-assisted matrix solid phase dispersion (VA-MSPD) with detection by liquid chromatography tandem mass spectrometry. Different types of solid supports and solvents were evaluated. The best results were found when 0.5g mussel shell, 0.5g sodium sulfate and 5mL ethanol were used. Analytical recoveries ranged from 81 to 110%, with RSD below 10%, whereas the matrix effect was between -17 and 1% (for all samples under study). LOQ values of irgarol and diuron were 5 and 50ngg -1 , respectively. The method under investigation proved to be a promising alternative to controlling contamination of fish by booster biocides, with low consumption of biodegradable reagents. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Citizenship and recovery: two intertwined concepts for civic-recovery.

    PubMed

    Pelletier, Jean-François; Corbière, Marc; Lecomte, Tania; Briand, Catherine; Corrigan, Patrick; Davidson, Larry; Rowe, Michael

    2015-03-04

    Validation of the psychometric properties of a new measure of citizenship was required for a research project in the province of Quebec, Canada. This study was meant to study the interplay between recovery- and citizenship-oriented supportive employment. As recovery and citizenship were expected to be two related concepts, convergent validity between the Citizenship Measure (CM) and the Recovery Assessment Scale (RAS) was tested. Study objectives were to: 1) conduct exploratory factor analyses on the CM and confirmatory factor analysis on the RAS tools (construct validity), 2) calculate Cronbach's alphas for each dimension emerging from objective 1 (reliability), and 3) calculate correlations between all dimensions from both tools (convergent validity). Data were collected from 174 individuals with serious mental illness, working in social firms. Serious mental illnesses include major depression, schizophrenia, bipolar disorder, obsessive compulsive disorder, panic disorder, post traumatic stress disorder and borderline personality disorder. Five factors emerged from the exploratory factor analysis of the CM, with good reliability. Confirmatory factor analyses showed that the short and the long versions of the RAS present satisfactory results. Finally, the correlation matrix indicated that all dimensions from both tools are significantly correlated, thus confirming their convergent validity. This study confirms the validity and reliability of two tools, CM and RAS. These tools can be used in combination to assess citizenship and recovery, both of which may be combined in the new concept of civic-recovery.

  1. Poly(glycerol sebacate urethane)-cellulose nanocomposites with water-active shape-memory effects.

    PubMed

    Wu, Tongfei; Frydrych, Martin; O'Kelly, Kevin; Chen, Biqiong

    2014-07-14

    Biodegradable and biocompatible materials with shape-memory effects (SMEs) are attractive for use as minimally invasive medical devices. Nanocomposites with SMEs were prepared from biodegradable poly(glycerol sebacate urethane) (PGSU) and renewable cellulose nanocrystals (CNCs). The effects of CNC content on the structure, water absorption, and mechanical properties of the PGSU were studied. The water-responsive mechanically adaptive properties and shape-memory performance of PGSU-CNC nanocomposites were observed, which are dependent on the content of CNCs. The PGSU-CNC nanocomposite containing 23.2 vol % CNCs exhibited the best SMEs among the nanocomposites investigated, with the stable shape fixing and shape recovery ratios being 98 and 99%, respectively, attributable to the formation of a hydrophilic, yet strong, CNC network in the elastomeric matrix. In vitro degradation profiles of the nanocomposites were assessed with and without the presence of an enzyme.

  2. Peripheral Nerve Regeneration by Secretomes of Stem Cells from Human Exfoliated Deciduous Teeth.

    PubMed

    Sugimura-Wakayama, Yukiko; Katagiri, Wataru; Osugi, Masashi; Kawai, Takamasa; Ogata, Kenichi; Sakaguchi, Kohei; Hibi, Hideharu

    2015-11-15

    Peripheral nerve regeneration across nerve gaps is often suboptimal, with poor functional recovery. Stem cell transplantation-based regenerative therapy is a promising approach for axon regeneration and functional recovery of peripheral nerve injury; however, the mechanisms remain controversial and unclear. Recent studies suggest that transplanted stem cells promote tissue regeneration through a paracrine mechanism. We investigated the effects of conditioned media derived from stem cells from human exfoliated deciduous teeth (SHED-CM) on peripheral nerve regeneration. In vitro, SHED-CM-treated Schwann cells exhibited significantly increased proliferation, migration, and the expression of neuron-, extracellular matrix (ECM)-, and angiogenesis-related genes. SHED-CM stimulated neuritogenesis of dorsal root ganglia and increased cell viability. Similarly, SHED-CM enhanced tube formation in an angiogenesis assay. In vivo, a 10-mm rat sciatic nerve gap model was bridged by silicon conduits containing SHED-CM or serum-free Dulbecco's modified Eagle's medium. Light and electron microscopy confirmed that the number of myelinated axons and axon-to-fiber ratio (G-ratio) were significantly higher in the SHED-CM group at 12 weeks after nerve transection surgery. The sciatic functional index (SFI) and gastrocnemius (target muscle) wet weight ratio demonstrated functional recovery. Increased compound muscle action potentials and increased SFI in the SHED-CM group suggested sciatic nerve reinnervation of the target muscle and improved functional recovery. We also observed reduced muscle atrophy in the SHED-CM group. Thus, SHEDs may secrete various trophic factors that enhance peripheral nerve regeneration through multiple mechanisms. SHED-CM may therefore provide a novel therapy that creates a more desirable extracellular microenvironment for peripheral nerve regeneration.

  3. Concentration of Enteroviruses, Adenoviruses, and Noroviruses from Drinking Water by Use of Glass Wool Filters▿

    PubMed Central

    Lambertini, Elisabetta; Spencer, Susan K.; Bertz, Phillip D.; Loge, Frank J.; Kieke, Burney A.; Borchardt, Mark A.

    2008-01-01

    Available filtration methods to concentrate waterborne viruses are either too costly for studies requiring large numbers of samples, limited to small sample volumes, or not very portable for routine field applications. Sodocalcic glass wool filtration is a cost-effective and easy-to-use method to retain viruses, but its efficiency and reliability are not adequately understood. This study evaluated glass wool filter performance to concentrate the four viruses on the U.S. Environmental Protection Agency contaminant candidate list, i.e., coxsackievirus, echovirus, norovirus, and adenovirus, as well as poliovirus. Total virus numbers recovered were measured by quantitative reverse transcription-PCR (qRT-PCR); infectious polioviruses were quantified by integrated cell culture (ICC)-qRT-PCR. Recovery efficiencies averaged 70% for poliovirus, 14% for coxsackievirus B5, 19% for echovirus 18, 21% for adenovirus 41, and 29% for norovirus. Virus strain and water matrix affected recovery, with significant interaction between the two variables. Optimal recovery was obtained at pH 6.5. No evidence was found that water volume, filtration rate, and number of viruses seeded influenced recovery. The method was successful in detecting indigenous viruses in municipal wells in Wisconsin. Long-term continuous filtration retained viruses sufficiently for their detection for up to 16 days after seeding for qRT-PCR and up to 30 days for ICC-qRT-PCR. Glass wool filtration is suitable for large-volume samples (1,000 liters) collected at high filtration rates (4 liters min−1), and its low cost makes it advantageous for studies requiring large numbers of samples. PMID:18359827

  4. Effect of molecular side groups and local nanoenvironment on photodegradation and its reversibility

    NASA Astrophysics Data System (ADS)

    Quist, Nicole; Li, Mark; Tollefsen, Ryan; Haley, Michael; Anthony, John; Ostroverkhova, Oksana

    2018-02-01

    Degradation of organic semiconductors in the presence of oxygen is one of the bottlenecks preventing their wide-spread use in optoelectronic devices. The first step towards such degradation in functionalized pentacene (Pn) derivatives is formation of endoperoxide (EPO), which can either revert back to the parent molecule or proceed to molecule decomposition. We present the study of reversibility of EPO formation through probing the photophysical properties of functionalized fluorinated pentacene (Pn-R-F8) derivatives. Experiments are done in solutions and in films both at the single molecule level and in the bulk. In solutions, degradation of optical absorption and its partial recovery after thermolysis were quantified for various derivatives depending on the solvent. At the single molecule level, low concentrations of each type of molecules were imaged in a variety of polymer matrices at 633 nm excitation at room temperature in air using wide-field fluorescence microscopy. Fluorescence time trajectories were collected and statistically analyzed to quantify blinking due to reversible EPO formation depending on the host matrix. To understand the physical changes of the molecular system, a Monte Carlo method was used to create a multi-level simulation, which enabled us to relate the change in the molecular transition rates to the experimentally measured parameters. At the bulk level, photoluminescence decay due to photobleaching and recovery due to EPO reconversion were measured for the same derivatives incorporated into various matrices. These studies provide insight into the synergistic effect of the local nanoenvironment and molecular side groups on the oxygen-related degradation and subsequent recovery which is important for development of organic electronic devices.

  5. Non-porous membrane-assisted liquid-liquid extraction of UV filter compounds from water samples.

    PubMed

    Rodil, Rosario; Schrader, Steffi; Moeder, Monika

    2009-06-12

    A method for the determination of nine UV filter compounds [benzophenone-3 (BP-3), isoamyl methoxycinnamate, 4-methylbenzylidene camphor, octocrylene (OC), butyl methoxydibenzoylmethane, ethylhexyl dimethyl p-aminobenzoate (OD-PABA), ethylhexyl methoxycinnamate (EHMC), ethylhexyl salicylate and homosalate] in water samples was developed and evaluated. The procedure includes non-porous membrane-assisted liquid-liquid extraction (MALLE) and LC-atmospheric pressure photoionization (APPI)-MS/MS. Membrane bags made of different polymeric materials were examined to enable a fast and simple extraction of the target analytes. Among the polymeric materials tested, low- and high-density polyethylene membranes proved to be well suited to adsorb the analytes from water samples. Finally, 2 cm length tailor-made membrane bags were prepared from low-density polyethylene in order to accommodate 100 microL of propanol. The fully optimised protocol provides recoveries from 76% to 101% and limits of detection (LOD) between 0.4 ng L(-1) (OD-PABA) and 16 ng L(-1) (EHMC). The interday repeatability of the whole protocol was below 18%. The effective separation of matrix molecules was proved by only marginal matrix influence during the APPI-MS analysis since no ion suppression effects were observed. During the extraction step, the influence of the matrix was only significant when non-treated wastewater was analysed. The analysis of lake water indicated the presence of seven UV filter compounds included in this study at concentrations between 40 ng L(-1) (BP-3) and 4381 ng L(-1) (OC). In non-treated wastewater several UV filters were also detected at concentration levels as high as 5322 ng L(-1) (OC).

  6. Effects of fiber pre-strain on the healing efficiency of thermoset polymers

    NASA Astrophysics Data System (ADS)

    Ajisafe, Oludayo

    One major challenge that has been facing material self healing is how to heal bigger macroscopic or structural scale damage autonomously, repeatedly, efficiently and at molecular length scale. Different approaches have been used to heal materials. However, none of them can heal macroscopic cracks. Our research group has proposed a novel shape-memory polymer (SMP) based, bio-inspired Close-Then-Heal (CTH) scheme to heal macroscopic cracks in SMP matrix. The most recent development in our group is to use SMP fibers to heal conventional thermosetting polymers according to the CTH scheme. The aim of this study is to further investigate the effect of pre-tension of SMP fibers during the cold-drawing programming on the self-healing efficiency of the conventional thermosetting polymer composites. This was done by fabricating a composite with thermoplastic particles (polycaprolactone) dispersed in a thermosetting polymer matrix (Epon 828). Shape memory fiber pre-tensioned into 3 different groups of 0%, 50% and 100% prestrain, was also embedded into the composite in the longitudinal direction. In this composite, the shape memory effect of the shape memory fibers is utilized for sealing (closing) the cracks and the thermoplastic particles are used for molecular-length scale healing. In this study, 7% by volume of thermoplastic particles was used. Beam specimens were prepared and controlled structural length scale damage was created prior to curing by inserting an aluminum foil of designed thickness in a perpendicular direction to the shape memory fibers before the matrix was allowed to cure. The aluminum sheet was removed post cure to leave a controlled damage. The specimen was healed by fixing the two ends of the beam and heating the sample above the Tg of the shape memory fiber. The recovery force of the sample was recorded and then the beam was tested again to fracture. This fracture healing cycle lasted 7 times. The healing efficiency was evaluated per the peak-tensile load. The Ultrasonic C-scan and SEM were used to examine the healed cracks. It was found that the beams with 100% pre-strained fiber were able to recover repeatedly about 50% of its peak tensile strength; the beams with 50% pre-strained fiber, 43%; and the beams with un-stretched fibers were able to recover about 21% of its original peak tensile strength. Also it was found that the higher the pre-tension the higher the recovery stress seen during the healing cycle.

  7. Evaluation of two methods to determine glyphosate and AMPA in soils of Argentina

    NASA Astrophysics Data System (ADS)

    De Geronimo, Eduardo; Lorenzon, Claudio; Iwasita, Barbara; Faggioli, Valeria; Aparicio, Virginia; Costa, Jose Luis

    2017-04-01

    Argentine agricultural production is fundamentally based on a technological package combining no-tillage and the dependence of glyphosate applications to control weeds in transgenic crops (soybean, maize and cotton). Therefore, glyphosate is the most employed herbicide in the country, where 180 to 200 million liters are applied every year. Due to its widespread use, it is important to assess its impact on the environment and, therefore, reliable analytical methods are mandatory. Glyphosate molecule exhibits unique physical and chemical characteristics which difficult its quantification, especially in soils with high organic matter content, such as the central eastern Argentine soils, where strong interferences are normally observed. The objective of this work was to compare two methods for extraction and quantification of glyphosate and AMPA in samples of 8 representative soils of Argentina. The first analytical method (method 1) was based on the use of phosphate buffer as extracting solution and dichloromethane to minimize matrix organic content. In the second method (method 2), potassium hydroxide was used to extract the analytes followed by a clean-up step using solid phase extraction (SPE) to minimize strong interferences. Sensitivity, recoveries, matrix effects and robustness were evaluated. Both methodologies involved a derivatization with 9-fluorenyl-methyl-chloroformate (FMOC) in borate buffer and detection based on ultra-high-pressure liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS). Recoveries obtained from soil samples spiked at 0.1 and 1 mg kg-1 and were satisfactory in both methods (70% - 120%). However, there was a remarkable difference regarding the matrix effect, being the SPE clean-up step (method 2) insufficient to remove the interferences. Whereas the dilution and the clean-up with dichloromethane (method 1) were more effective minimizing the ionic suppression. Moreover, method 1 had fewer steps in the protocol of sample processing than method 2. This can be highly valuable in the routine lab work due to the reduction of potential undesired errors such as the loss of analyte or sample contamination. In addition, the substitution of SPE by another alternative involved a considerable reduction of analytical costs in method 1. We conclude that method 1 seemed to be simpler and cheaper than method 2, as well as reliable to quantify glyphosate in Argentinean soils. We hope that this experience can be useful to simplify the protocols of glyphosate quantification and contribute to the understanding of the fate of this herbicide in the environment.

  8. Deployment of Cesium Recovered from High Level Liquid Waste for Irradiation - Indian Scenario - 13128

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vincent, Tessy; Shah, J.G.; Kumar, Amar

    2013-07-01

    Recovery of Cs-137 from HLW and its utilisation as source pencil in place of Co-60 is vital for medical and sewage treatment applications in India. For separation of Cs, specific ion exchange resins as well as 'Calyx crown' solvent have been developed and synthesized indigenously. A flow sheet involving separation of Cs from acidic HLW using Ammonium Molybdo Phosphate (AMP) resins, recovery of Cs from the loaded AMP column by dissolving it in alkali, ion exchange purification of Cs rich alkaline solution using Resorcinol-Formaldehyde Poly condensate (RF) resins and its elution in cesium nitrate form was developed and demonstrated. Solventmore » extraction route employing 0.03 Molar, 1-3-octyl oxy Calyx (4) arene crown-6 in 30% isodecyl alcohol and dodecane was also established using mixer settlers. Cesium lithium borosilicate glass based formulations have been considered as a glass matrix for Cs irradiation pencils. While choosing this vitreous matrix, attributes addressing maximum possible Cs-137 loading, low glass pouring temperature to minimise Cs volatility, reasonably good mechanical strength and good chemical durability have been considered. Recovered cesium nitrate solution was vitrified along with glass additives in an induction heated metallic melter and subsequently poured into 12 numbers of Cs irradiation pencils positioned on turn-table equipped with the load cell. The complete cycle involving recovery of Cs from HLW followed by its conversion into Cs pencil was demonstrated. (authors)« less

  9. Method Development for Comprehensive Extraction and Analysis of Marine Toxins: Liquid-Liquid Extraction and Tandem Liquid Chromatography Separations Coupled to Electrospray Tandem Mass Spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wunschel, David S.; Valenzuela, Blandina R.; Kaiser, Brooke L. Deatherage

    A variety of toxins are produced by marine and freshwater microorganisms that present a threat to human health. These toxins have diverse chemical properties and specifically, a range of hydrophobicity. Methods for extraction and identification of these toxins are often geared toward specific classes of toxin depending on the sample type. There is a need for a general method of toxin extraction and identification for screening samples where the likely toxin content is not known a priori. Here, we have applied a general method for metabolite extraction to toxin containing samples. This method was coupled with a simple dual liquidmore » chromatography approach for separating a broad range of toxins. This liquid chromatography approach was coupled to triple quadrupole and quadrupole time-of-flight MS/MS platforms. The method was testing on a fish matrix for recovery of palytoxin as well as marine corals for detection of natural mixtures of palytoxin analogues. The recovery of palytoxin was found to produce a linear response (R 2 of 0.95) when spiked into the fish matrix with a limit of quantitation of 2.5 ng/μL and recovery efficiency of 73% +/- 9%. The screening of corals revealed varying amount of palytoxin, and in one case, different palytoxin structural analogues. This demonstration illustrates the potential utility of this method for toxin extraction and detection.« less

  10. Method Development for Comprehensive Extraction and Analysis of Marine Toxins: Liquid-Liquid Extraction and Tandem Liquid Chromatography Separations Coupled to Electrospray Tandem Mass Spectrometry

    DOE PAGES

    Wunschel, David S.; Valenzuela, Blandina R.; Kaiser, Brooke L. Deatherage; ...

    2018-05-09

    A variety of toxins are produced by marine and freshwater microorganisms that present a threat to human health. These toxins have diverse chemical properties and specifically, a range of hydrophobicity. Methods for extraction and identification of these toxins are often geared toward specific classes of toxin depending on the sample type. There is a need for a general method of toxin extraction and identification for screening samples where the likely toxin content is not known a priori. Here, we have applied a general method for metabolite extraction to toxin containing samples. This method was coupled with a simple dual liquidmore » chromatography approach for separating a broad range of toxins. This liquid chromatography approach was coupled to triple quadrupole and quadrupole time-of-flight MS/MS platforms. The method was testing on a fish matrix for recovery of palytoxin as well as marine corals for detection of natural mixtures of palytoxin analogues. The recovery of palytoxin was found to produce a linear response (R 2 of 0.95) when spiked into the fish matrix with a limit of quantitation of 2.5 ng/μL and recovery efficiency of 73% +/- 9%. The screening of corals revealed varying amount of palytoxin, and in one case, different palytoxin structural analogues. This demonstration illustrates the potential utility of this method for toxin extraction and detection.« less

  11. Enhanced oil displacement by nanofluid's structural disjoining pressure in model fractured porous media.

    PubMed

    Zhang, Hua; Ramakrishnan, T S; Nikolov, Alex; Wasan, Darsh

    2018-02-01

    Nanofluids for improved oil recovery has been demonstrated through laboratory corefloods. Despite numerous experimental studies, little is known about the efficacy of nanofluids in fractured systems. Here, we present studies of nanofluid injection in fractured porous media (both water-wet and oil-wet) formed by sintering borosilicate glass-beads around a dissolvable substrate. The fracture inside the porous medium is characterized and visualized using a high resolution X-ray microtomography. Based on a simple displacement theory, the nanofluid injection is conducted at a rate where structural disjoining pressure driven oil recovery is operational. An additional 23.8% oil was displaced using nanofluid after brine injection with an overall recovery efficiency of 90.4% provided the matrix was in its native wettability state. But only 6% additional oil was displaced by nanofluid following brine injection when the bead-pack was rendered oil-wet. Nanofluids appear to be a good candidate for enhanced oil recovery (EOR) in fractured water-wet to weakly water-wet media but not necessarily for strongly oil-wet systems. Our laboratory studies enable us to understand limitations of nanofluids for improving oil recovery in fractured media. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Multispectral decomposition for the removal of out-of-band effects of visible/infrared imaging radiometer suite visible and near-infrared bands.

    PubMed

    Gao, Bo-Cai; Chen, Wei

    2012-06-20

    The visible/infrared imaging radiometer suite (VIIRS) is now onboard the first satellite platform managed by the Joint Polar Satellite System of the National Oceanic and Atmospheric Administration and NASA. It collects scientific data from an altitude of approximately 830 km in 22 narrow bands located in the 0.4-12.5 μm range. The seven visible and near-infrared (VisNIR) bands in the wavelength interval between 0.4-0.9 μm are known to suffer from the out-of-band (OOB) responses--a small amount of radiances far away from the center of a given band that can pass through the filter and reach detectors in the focal plane. A proper treatment of the OOB effects is necessary in order to obtain calibrated at-sensor radiance data [referred to as the Sensor Data Records (SDRs)] from measurements with these bands and subsequently to derive higher-level data products [referred to as the Environmental Data Records (EDRs)]. We have recently developed a new technique, called multispectral decomposition transform (MDT), which can be used to correct/remove the OOB effects of VIIRS VisNIR bands and to recover the true narrow band radiances from the measured radiances containing OOB effects. An MDT matrix is derived from the laboratory-measured filter transmittance functions. The recovery of the narrow band signals is performed through a matrix multiplication--the production between the MDT matrix and a multispectral vector. Hyperspectral imaging data measured from high altitude aircraft and satellite platforms, the complete VIIRS filter functions, and the truncated VIIRS filter functions to narrower spectral intervals, are used to simulate the VIIRS data with and without OOB effects. Our experimental results using the proposed MDT method have demonstrated that the average errors after decomposition are reduced by more than one order of magnitude.

  13. Digestive recovery of sulfur-methyl-L-methionine and its bioaccessibility in Kimchi cabbages using a simulated in vitro digestion model system.

    PubMed

    Lee, Hae-Rim; Cho, Sun-Duk; Lee, Woon Kyu; Kim, Gun-Hee; Shim, Soon-Mi

    2014-01-15

    Sulfur-methyl-L-methionine (SMM) has been known to provide various biological functions such as radical scavenging effect, inhibition of adipocyte differentiation, and prevention of gastric mucosal damage. Kimchi cabbages are known to be a major food source providing SMM but its bioaccessibility has not been studied. The objective of current study was to determine both the digestive stability of SMM and the amount released from Kimchi cabbages under a simulated in vitro digestion model system. The in vitro digestion model system simulating a human gastrointestinal tract was carried out for measuring digestive recovery and bioaccessibility of SMM. SMM was quantified by using high-performance liquid chromatography with a fluorescence detector. Recovery of an SMM standard after digestion was 0.68 and 0.65% for fasted and fed conditions, respectively, indicating that the digestive stability of the SMM standard was not affected by dietary energy or co-ingested food matrix. The SMM standard was also significantly stable in acidic pH (P < 0.05). The bioaccessibility of SMM from Kimchi cabbages was measured under a fasted condition, resulted in 8.83, 14.71 and 10.88%, for salivary, gastric and small intestinal phases, respectively. Results from our study suggest that SMM from Kimchi cabbages, a component of food sources, is more bioavailable than SMM by itself. © 2013 Society of Chemical Industry.

  14. Force and time-dependent self-assembly, disruption and recovery of supramolecular peptide amphiphile nanofibers

    NASA Astrophysics Data System (ADS)

    Begum Dikecoglu, F.; Topal, Ahmet E.; Ozkan, Alper D.; Deniz Tekin, E.; Tekinay, Ayse B.; Guler, Mustafa O.; Dana, Aykutlu

    2018-07-01

    Biological feedback mechanisms exert precise control over the initiation and termination of molecular self-assembly in response to environmental stimuli, while minimizing the formation and propagation of defects through self-repair processes. Peptide amphiphile (PA) molecules can self-assemble at physiological conditions to form supramolecular nanostructures that structurally and functionally resemble the nanofibrous proteins of the extracellular matrix, and their ability to reconfigure themselves in response to external stimuli is crucial for the design of intelligent biomaterials systems. Here, we investigated real-time self-assembly, deformation, and recovery of PA nanofibers in aqueous solution by using a force-stabilizing double-pass scanning atomic force microscopy imaging method to disrupt the self-assembled peptide nanofibers in a force-dependent manner. We demonstrate that nanofiber damage occurs at tip-sample interaction forces exceeding 1 nN, and the damaged fibers subsequently recover when the tip pressure is reduced. Nanofiber ends occasionally fail to reconnect following breakage and continue to grow as two individual nanofibers. Energy minimization calculations of nanofibers with increasing cross-sectional ellipticity (corresponding to varying levels of tip-induced fiber deformation) support our observations, with high-ellipticity nanofibers exhibiting lower stability compared to their non-deformed counterparts. Consequently, tip-mediated mechanical forces can provide an effective means of altering nanofiber integrity and visualizing the self-recovery of PA assemblies.

  15. Force and time-dependent self-assembly, disruption and recovery of supramolecular peptide amphiphile nanofibers.

    PubMed

    Dikecoglu, F Begum; Topal, Ahmet E; Ozkan, Alper D; Tekin, E Deniz; Tekinay, Ayse B; Guler, Mustafa O; Dana, Aykutlu

    2018-07-13

    Biological feedback mechanisms exert precise control over the initiation and termination of molecular self-assembly in response to environmental stimuli, while minimizing the formation and propagation of defects through self-repair processes. Peptide amphiphile (PA) molecules can self-assemble at physiological conditions to form supramolecular nanostructures that structurally and functionally resemble the nanofibrous proteins of the extracellular matrix, and their ability to reconfigure themselves in response to external stimuli is crucial for the design of intelligent biomaterials systems. Here, we investigated real-time self-assembly, deformation, and recovery of PA nanofibers in aqueous solution by using a force-stabilizing double-pass scanning atomic force microscopy imaging method to disrupt the self-assembled peptide nanofibers in a force-dependent manner. We demonstrate that nanofiber damage occurs at tip-sample interaction forces exceeding 1 nN, and the damaged fibers subsequently recover when the tip pressure is reduced. Nanofiber ends occasionally fail to reconnect following breakage and continue to grow as two individual nanofibers. Energy minimization calculations of nanofibers with increasing cross-sectional ellipticity (corresponding to varying levels of tip-induced fiber deformation) support our observations, with high-ellipticity nanofibers exhibiting lower stability compared to their non-deformed counterparts. Consequently, tip-mediated mechanical forces can provide an effective means of altering nanofiber integrity and visualizing the self-recovery of PA assemblies.

  16. Enhanced cryopreservation of MSCs in microfluidic bioreactor by regulated shear flow

    PubMed Central

    Bissoyi, Akalabya; Bit, Arindam; Singh, Bikesh Kumar; Singh, Abhishek Kumar; Patra, Pradeep Kumar

    2016-01-01

    Cell-matrix systems can be stored for longer period of time by means of cryopreservation. Cell-matrix and cell-cell interaction has been found to be critical in a number of basic biological processes. Tissue structure maintenance, cell secretary activity, cellular migration, and cell-cell communication all exist because of the presence of cell interactions. This complex and co-ordinated interaction between cellular constituents, extracellular matrix and adjacent cells has been identified as a significant contributor in the overall co-ordination of tissue. The prime objective of this investigation is to evaluate the effects of shear-stress and cell-substrate interaction in successful recovery of adherent human mesenchymal-stem-cells (hMSCs). A customized microfluidic bioreactor has been used for the purpose. We have measured the changes in focal-point-adhesion (FPAs) by changing induced shear stress inside the bioreactor. The findings indicate that with increase in shear stress, FPAs increases between substrate and MSCs. Further, experimental results show that increased FPAs (4e-3 μbar) enhances the cellular survivability of adherent MSCs. Probably, for the first time involvement of focal point interaction in the outcome of cryopreservation of MSCs has been clarified, and it proved a potentially new approach for modification of cryopreservation protocol by up-regulating focal point of cells to improve its clinical application. PMID:27748463

  17. Pesticide residues in fruit samples: comparison of different QuEChERS methods using liquid chromatography-tandem mass spectrometry.

    PubMed

    Christia, C; Bizani, E; Christophoridis, C; Fytianos, K

    2015-09-01

    Acetate- and citrate-buffered quick, easy, cheap, effective, rugged, safe (QuEChERS) pretreatment methods were evaluated for the determination of various pesticides in peaches, grapes, apples, bananas, pears, and strawberries from various regions of Greece, using LC-MS/MS. The purposes of this study were (i) to evaluate which type of QuEChERS method was the most appropriate and effective for each matrix; (ii) to apply the selected QuEChERS method for each matrix, in order to detect and quantify pesticide residues in various fruit samples using UPLC-MS/MS; (iii) to examine the concentration distribution of pesticide classes among fruit originating from various areas; and (iv) to assess pesticide concentration distribution between peel and flesh of fruit in order to evaluate the penetration of pesticide residues in the fruit flesh. Acetate-buffered QuEChERS was found to be the most suitable technique for most of the fruit matrices. According to the recovery values at two different concentration levels, peaches should preferably be treated by the citrate-buffered type, whereas grapes, bananas, apples, pears, and strawberries are best treated by the acetate-buffered version, although the differences in efficiency were small. The addition of graphitized carbon black significantly decreases the recovery of specific pesticides in all matrices except for strawberries. The majority of values do not exceed the official maximum residue levels set by the European Commission. Organophosphates proved to be the most commonly detected category along with triazines-triazoles-conazoles group and by carbamates. Apples and pears seem to be the most contaminated fruit matrices among those tested. Distribution of pesticide classes shows variations between different regions, suggesting different pesticide application practices. In the case of peaches and pears, there is an equal distribution of detected pesticides between peel and flesh, indicating penetration of contaminants into the fruit flesh.

  18. Comparison of two extraction methods for the determination of 135 pesticides in Corydalis Rhizoma, Chuanxiong Rhizoma and Angelicae Sinensis Radix by liquid chromatography-triple quadrupole-mass spectrometry. Application to the roots and rhizomes of Chinese herbal medicines.

    PubMed

    Liu, Jie; Tong, Ling; Li, Dongxiang; Meng, Wenting; Sun, Wanyang; Zhao, Yunli; Yu, Zhiguo

    2016-04-01

    In this study, two simple pretreatment methods were comprehensively evaluated for the determination of 135 pesticide residues in roots and rhizomes of Chinese herbal medicines (CHMs). The studied methodologies are (a) solid-phase extraction (SPE) and (b) Quick, Easy, Cheap, Effective, Rugged and Safe (QuEChERS). For SPE, extraction solvents, SPE cartridges and types and volume of eluent were accessed and optimized. For QuEChERS, different versions, acetic acid concentration and dispersive solid-phase extraction (dSPE) sorbent materials were tested. SPE and QuEChERS were estimated in recovery range, the number of pesticides that were recovered ranging from 90% to 110% and expenses in Corydalis Rhizoma, Chuanxiong Rhizoma and Angelicae Sinensis Radix. QuEChERS method showed better performance than SPE. The method showed good linearity over the range assayed 0.9986-0.9999 (1-80ng/mL for 124 pesticides, 1-50ng/mL for 10 pesticides, 1-20ng/mL for satisfar). The matrix effect was compensated by matrix-based calibration curves with internal standard. The average recoveries of all pesticides were ranging from 70% to 120% at three levels of 10, 50 and 100ng/g with relative standard deviations less than 20%. The limits of quantification of the 135 pesticides in three matrices were 1-5ng/g, which were below the maximum residue levels (MRLs) established by the European Union. The verified QuEChERS method was successfully applied to the analysis of 65 actual samples from eight different types of roots and rhizomes of CHMs. Angelicae Sinensis Radix was the most susceptible to pesticides among these samples, and the most frequently detected pesticide was carbendazim with levels below MRLs. Metalaxyl, phorate, atrazine, diniconazole, coumaphos and paclobutrazol were also detected in some samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. A geochemical investigation into the effect of coal rank on the potential environmental effects of CO2 sequestration in deep coal beds

    USGS Publications Warehouse

    Kolak, Jonathan J.; Burruss, Robert A.

    2005-01-01

    Coal samples of different rank were extracted in the laboratory with supercritical CO2 to evaluate the potential for mobilizing hydrocarbons during CO2 sequestration or enhanced coal bed methane recovery from deep coal beds. The concentrations of aliphatic hydrocarbons mobilized from the subbituminous C, high-volatile C bituminous, and anthracite coal samples were 41.2, 43.1, and 3.11 ?g g-1 dry coal, respectively. Substantial, but lower, concentrations of polycyclic aromatic hydrocarbons (PAHs) were mobilized from these samples: 2.19, 10.1, and 1.44 ?g g-1 dry coal, respectively. The hydrocarbon distributions within the aliphatic and aromatic fractions obtained from each coal sample also varied with coal rank and reflected changes to the coal matrix associated with increasing degree of coalification. Bitumen present within the coal matrix may affect hydrocarbon partitioning between coal and supercritical CO2. The coal samples continued to yield hydrocarbons during consecutive extractions with supercritical CO2. The amount of hydrocarbons mobilized declined with each successive extraction, and the relative proportion of higher molecular weight hydrocarbons increased during successive extractions. These results demonstrate that the potential for mobilizing hydrocarbons from coal beds, and the effect of coal rank on this process, are important to consider when evaluating coal beds for CO2 storage.

  20. Biopolymer system for permeability modification in porous media

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stepp, A.K.; Bryant, R.S.; Llave, F.M.

    1995-12-31

    New technologies are needed to reduce the current high rate of well abandonment. Improved sweep efficiency, reservoir conformance, and permeability modification can have a significant impact on oil recovery processes. Microorganisms can be used to selectively plug high-permeability zones to improve sweep efficiency and impart conformance control. Studies of a promising microbial system for polymer production were conducted to evaluate reservoir conditions in which this system would be effective. Factors which can affect microbial growth and polymer production include salinity, pH, temperature, divalent ions, presence of residual oil, and rock matrix. Flask tests and coreflooding experiments were conducted to optimizemore » and evaluate the effectiveness of this system. Nuclear magnetic resonance imaging (NMRI) was used to visualize microbial polymer production in porous media. Changes in fluid distribution within the pore system of the core were detected.« less

  1. A novel optimised and validated method for analysis of multi-residues of pesticides in fruits and vegetables by microwave-assisted extraction (MAE)-dispersive solid-phase extraction (d-SPE)-retention time locked (RTL)-gas chromatography-mass spectrometry with Deconvolution reporting software (DRS).

    PubMed

    Satpathy, Gouri; Tyagi, Yogesh Kumar; Gupta, Rajinder Kumar

    2011-08-01

    A rapid, effective and ecofriendly method for sensitive screening and quantification of 72 pesticides residue in fruits and vegetables, by microwave-assisted extraction (MAE) followed by dispersive solid-phase extraction (d-SPE), retention time locked (RTL) capillary gas-chromatographic separation in trace ion mode mass spectrometric determination has been validated as per ISO/IEC: 17025:2005. Identification and reporting with total and extracted ion chromatograms were facilitated to a great extent by Deconvolution reporting software (DRS). For all compounds LOD were 0.002-0.02mg/kg and LOQ were 0.025-0.100mg/kg. Correlation coefficients of the calibration curves in the range of 0.025-0.50mg/kg were >0.993. To validate matrix effects repeatability, reproducibility, recovery and overall uncertainty were calculated for the 35 matrices at 0.025, 0.050 and 0.100mg/kg. Recovery ranged between 72% and 114% with RSD of <20% for repeatability and intermediate precision. The reproducibility of the method was evaluated by an inter laboratory participation and Z score obtained within ±2. Copyright © 2011 Elsevier Ltd. All rights reserved.

  2. Development and validation of a solid-phase extraction method coupled with HPLC-UV detection for the determination of biogenic amines in Chinese rice wine.

    PubMed

    Zhang, Ying; Li, Yan; Zhu, Xiao-Juan; Li, Min; Chen, Hao-Yu; Lv, Xiao-Ling; Zhang, Jian

    2017-07-01

    A reliable and accurate method for the determination of seven biogenic amines (BAs) was developed and validated with Chinese rice wine samples. The BAs were derivatised with dansyl chloride, cleaned up using solid-phase extraction (SPE) and separated by high-performance liquid chromatography (HPLC) coupled with ultraviolet (UV) detection. The optimised derivatisation reaction, conducted at pH 9.6 and 60°C for 30 min, ensured baseline separation and peak symmetry for each BA. SPE clean-up using Oasis MCX cartridges yielded good recovery rates for all BAs and effectively reduced matrix effects. The developed method shows good linearity with determination coefficients of more than 0.9989 over a concentration range of 0.1-100 mg l -1 . The limits of detection (LODs) for the investigated BAs ranged from 2.07 to 5.56 µg l -1 . The intra- and inter-day relative standard deviations (RSDs) ranged from 0.86% to 3.81% and from 2.13% to 3.82%, respectively. Spiking experiments showed that the overall recovery rates ranged from 85% to 113%. Thus, the proposed method was demonstrated as being suitable for simultaneous detection, with accurate and precise quantification, of BAs in Chinese rice wine.

  3. Design and optimization of integrated gas/condensate plants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Root, C.R.; Wilson, J.L.

    1995-11-01

    An optimized design is demonstrated for combining gas processing and condensate stabilization plants into a single integrated process facility. This integrated design economically provides improved condensate recovery versus use of a simple stabilizer design. A selection matrix showing likely application of this integrated process is presented for use on future designs. Several methods for developing the fluid characterization and for using a process simulator to predict future design compositions are described, which could be useful in other designs. Optimization of flowsheet equipment choices and of design operating pressures and temperatures is demonstrated including the effect of both continuous and discretemore » process equipment size changes. Several similar designs using a turboexpander to provide refrigeration for liquids recovery and stabilizer reflux are described. Operating overthrust and from the P/15-D platform in the Dutch sector of the North Sea has proven these integrated designs are effective. Concerns do remain around operation near or above the critical pressure that should be addressed in future work including providing conservative separator designs, providing sufficient process design safety margin to meet dew point specifications, selecting the most conservative design values of predicted gas dew point and equipment size calculated with different Equations-of-State, and possibly improving the accuracy of PVT calculations in the near critical area.« less

  4. Sensitive Detection of Neonicotinoid Insecticides and Other Selected Pesticides in Pollen and Nectar Using Nanoflow Liquid Chromatography Orbitrap Tandem Mass Spectrometry.

    PubMed

    Moreno-González, David; Alcántara-Durán, Jaime; Gilbert-López, Bienvenida; Beneito-Cambra, Miriam; Cutillas, Víctor M; Rajski, Łukasz; Molina-Díaz, Antonio; García-Reyes, Juan F

    2018-03-01

    In this work, a new method based on nanoflow LC with high-resolution MS was developed for the determination of eight pesticides in pollen and nectar samples, including neonicotinoid insecticides and other selected pesticides commonly found in bees and beeswax. Detection was undertaken with a hybrid quadrupole-Orbitrap mass spectrometer (Q Exactive™) equipped with a commercial nanospray ion source. The extraction of pesticides from pollen samples was performed by a modified micro-QuEChERS method scaled down to Eppendorf tubes, whereas nectar samples were simply diluted with a water-methanol (95 + 5, v/v) solution. Good linearity (>0.999 in all cases) was obtained between 0.05 and 500 µg/kg and between 0.04 and 400 µg/kg for pollen and nectar, respectively. Recovery rates in pollen ranged from 85 to 97%, with RSDs <12%. Matrix effect was evaluated and showed negligible effects for all studied pesticides. The lowest concentration levels tested and validated were 0.5 and 0.4 µg/kg for pollen and nectar matrixes, respectively. In addition, selected incurred samples were studied, obtaining several positive findings in pollen and nectar samples, demonstrating the sensitivity and applicability of the proposed method.

  5. Dual ultrasonic-assisted dispersive liquid-liquid microextraction coupled with microwave-assisted derivatization for simultaneous determination of 20(S)-protopanaxadiol and 20(S)-protopanaxatriol by ultra high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Zhao, Xian-En; Lv, Tao; Zhu, Shuyun; Qu, Fei; Chen, Guang; He, Yongrui; Wei, Na; Li, Guoliang; Xia, Lian; Sun, Zhiwei; Zhang, Shijuan; You, Jinmao; Liu, Shu; Liu, Zhiqiang; Sun, Jing; Liu, Shuying

    2016-03-11

    This paper, for the first time, reported a speedy hyphenated technique of low toxic dual ultrasonic-assisted dispersive liquid-liquid microextraction (dual-UADLLME) coupled with microwave-assisted derivatization (MAD) for the simultaneous determination of 20(S)-protopanaxadiol (PPD) and 20(S)-protopanaxatriol (PPT). The developed method was based on ultra high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) detection using multiple-reaction monitoring (MRM) mode. A mass spectrometry sensitizing reagent, 4'-carboxy-substituted rosamine (CSR) with high reaction activity and ionization efficiency was synthesized and firstly used as derivatization reagent. Parameters of dual-UADLLME, MAD and UHPLC-MS/MS conditions were all optimized in detail. Low toxic brominated solvents were used as extractant instead of traditional chlorinated solvents. Satisfactory linearity, recovery, repeatability, accuracy and precision, absence of matrix effect and extremely low limits of detection (LODs, 0.010 and 0.015ng/mL for PPD and PPT, respectively) were achieved. The main advantages were rapid, sensitive and environmentally friendly, and exhibited high selectivity, accuracy and good matrix effect results. The proposed method was successfully applied to pharmacokinetics of PPD and PPT in rat plasma. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Hindrances to precise recovery of cellular forces in fibrous biopolymer networks.

    PubMed

    Zhang, Yunsong; Feng, Jingchen; Heizler, Shay I; Levine, Herbert

    2018-01-11

    How cells move through the three-dimensional extracellular matrix (ECM) is of increasing interest in attempts to understand important biological processes such as cancer metastasis. Just as in motion on flat surfaces, it is expected that experimental measurements of cell-generated forces will provide valuable information for uncovering the mechanisms of cell migration. However, the recovery of forces in fibrous biopolymer networks may suffer from large errors. Here, within the framework of lattice-based models, we explore possible issues in force recovery by solving the inverse problem: how can one determine the forces cells exert to their surroundings from the deformation of the ECM? Our results indicate that irregular cell traction patterns, the uncertainty of local fiber stiffness, the non-affine nature of ECM deformations and inadequate knowledge of network topology will all prevent the precise force determination. At the end, we discuss possible ways of overcoming these difficulties.

  7. Seawater-cultured Botryococcus braunii for efficient hydrocarbon extraction.

    PubMed

    Furuhashi, Kenichi; Saga, Kiyotaka; Okada, Shigeru; Imou, Kenji

    2013-01-01

    As a potential source of biofuel, the green colonial microalga Botryococcus braunii produces large amounts of hydrocarbons that are accumulated in the extracellular matrix. Generally, pretreatment such as drying or heating of wet algae is needed for sufficient recoveries of hydrocarbons from B. braunii using organic solvents. In this study, the Showa strain of B. braunii was cultured in media derived from the modified Chu13 medium by supplying artificial seawater, natural seawater, or NaCl. After a certain period of culture in the media with an osmotic pressure corresponding to 1/4-seawater, hydrocarbon recovery rates exceeding 90% were obtained by simply mixing intact wet algae with n-hexane without any pretreatments and the results using the present culture conditions indicate the potential for hydrocarbon milking. Seawater was used for efficient hydrocarbon extraction from Botryococcus braunii. The alga was cultured in media prepared with seawater or NaCl. Hydrocarbon recovery rate exceeding 90% was obtained without any pretreatment.

  8. Hindrances to precise recovery of cellular forces in fibrous biopolymer networks

    NASA Astrophysics Data System (ADS)

    Zhang, Yunsong; Feng, Jingchen; Heizler, Shay I.; Levine, Herbert

    2018-03-01

    How cells move through the three-dimensional extracellular matrix (ECM) is of increasing interest in attempts to understand important biological processes such as cancer metastasis. Just as in motion on flat surfaces, it is expected that experimental measurements of cell-generated forces will provide valuable information for uncovering the mechanisms of cell migration. However, the recovery of forces in fibrous biopolymer networks may suffer from large errors. Here, within the framework of lattice-based models, we explore possible issues in force recovery by solving the inverse problem: how can one determine the forces cells exert to their surroundings from the deformation of the ECM? Our results indicate that irregular cell traction patterns, the uncertainty of local fiber stiffness, the non-affine nature of ECM deformations and inadequate knowledge of network topology will all prevent the precise force determination. At the end, we discuss possible ways of overcoming these difficulties.

  9. Inner Space Perturbation Theory in Matrix Product States: Replacing Expensive Iterative Diagonalization.

    PubMed

    Ren, Jiajun; Yi, Yuanping; Shuai, Zhigang

    2016-10-11

    We propose an inner space perturbation theory (isPT) to replace the expensive iterative diagonalization in the standard density matrix renormalization group theory (DMRG). The retained reduced density matrix eigenstates are partitioned into the active and secondary space. The first-order wave function and the second- and third-order energies are easily computed by using one step Davidson iteration. Our formulation has several advantages including (i) keeping a balance between the efficiency and accuracy, (ii) capturing more entanglement with the same amount of computational time, (iii) recovery of the standard DMRG when all the basis states belong to the active space. Numerical examples for the polyacenes and periacene show that the efficiency gain is considerable and the accuracy loss due to the perturbation treatment is very small, when half of the total basis states belong to the active space. Moreover, the perturbation calculations converge in all our numerical examples.

  10. Online blind source separation using incremental nonnegative matrix factorization with volume constraint.

    PubMed

    Zhou, Guoxu; Yang, Zuyuan; Xie, Shengli; Yang, Jun-Mei

    2011-04-01

    Online blind source separation (BSS) is proposed to overcome the high computational cost problem, which limits the practical applications of traditional batch BSS algorithms. However, the existing online BSS methods are mainly used to separate independent or uncorrelated sources. Recently, nonnegative matrix factorization (NMF) shows great potential to separate the correlative sources, where some constraints are often imposed to overcome the non-uniqueness of the factorization. In this paper, an incremental NMF with volume constraint is derived and utilized for solving online BSS. The volume constraint to the mixing matrix enhances the identifiability of the sources, while the incremental learning mode reduces the computational cost. The proposed method takes advantage of the natural gradient based multiplication updating rule, and it performs especially well in the recovery of dependent sources. Simulations in BSS for dual-energy X-ray images, online encrypted speech signals, and high correlative face images show the validity of the proposed method.

  11. Approximate equiangular tight frames for compressed sensing and CDMA applications

    NASA Astrophysics Data System (ADS)

    Tsiligianni, Evaggelia; Kondi, Lisimachos P.; Katsaggelos, Aggelos K.

    2017-12-01

    Performance guarantees for recovery algorithms employed in sparse representations, and compressed sensing highlights the importance of incoherence. Optimal bounds of incoherence are attained by equiangular unit norm tight frames (ETFs). Although ETFs are important in many applications, they do not exist for all dimensions, while their construction has been proven extremely difficult. In this paper, we construct frames that are close to ETFs. According to results from frame and graph theory, the existence of an ETF depends on the existence of its signature matrix, that is, a symmetric matrix with certain structure and spectrum consisting of two distinct eigenvalues. We view the construction of a signature matrix as an inverse eigenvalue problem and propose a method that produces frames of any dimensions that are close to ETFs. Due to the achieved equiangularity property, the so obtained frames can be employed as spreading sequences in synchronous code-division multiple access (s-CDMA) systems, besides compressed sensing.

  12. Signal Recovery and System Calibration from Multiple Compressive Poisson Measurements

    DOE PAGES

    Wang, Liming; Huang, Jiaji; Yuan, Xin; ...

    2015-09-17

    The measurement matrix employed in compressive sensing typically cannot be known precisely a priori and must be estimated via calibration. One may take multiple compressive measurements, from which the measurement matrix and underlying signals may be estimated jointly. This is of interest as well when the measurement matrix may change as a function of the details of what is measured. This problem has been considered recently for Gaussian measurement noise, and here we develop this idea with application to Poisson systems. A collaborative maximum likelihood algorithm and alternating proximal gradient algorithm are proposed, and associated theoretical performance guarantees are establishedmore » based on newly derived concentration-of-measure results. A Bayesian model is then introduced, to improve flexibility and generality. Connections between the maximum likelihood methods and the Bayesian model are developed, and example results are presented for a real compressive X-ray imaging system.« less

  13. Do reclamation speed up recovery of soil and soil biota on post mining sites along climatic gradient across continental USA?

    NASA Astrophysics Data System (ADS)

    Frouz, Jan

    2015-04-01

    Soil biota community (macrofauna, nematodes and microbial community studied by PLFA) was studied together with soil development in post-mining chronosequences along climatic gradient in the USA, covering hardwood forest (TN, IN), tallgrass prairie (IL), or shortgrass prairie (WY). Post mining sites reclaimed according recent regulation which includes topsoil application and vegetation establishment were compared to local climax. Both young and old restoration sites were much closer to the climax condition in shortgrass prairie than in the other sites. The shortgrass prairie soil community contained abundant root-feeding organisms, which may establish quicker than the saprophagous fauna that was abundant at the other sites. Absence of saprophagous groups, and especially earthworms, resulted in the absence of bioturbation in shortgrass prairie sites while in chronosequences other than the one in shortgrass prairie, bioturbation played an important role in topsoil formation resulting in more complex soil profile development compare to shortgrass prairie. This may contribute to faster recovery communities in shortgrass prairie in comparison with tallgrass prairie and forest as At the same time sites that were reclaimed according recent regulation (topsoil application and vegetation establishment) were compare to unreclaimed sites both about 30 years old in TN IL and WY. It TN soil and soil biota seems to approach fasted to climax in unreclaimed than reclaimed sites. In IL this differences between reclaimed and unreclaimed sites was not so clear. While in WY reclaimed sites seems to approach to climax community fasted than unreclaimed one. This suggests that effect of reclamation vary along climatic gradient. In drier sites, formation of soil matrix from parent material is probably much slower and topsoil application speed up soil community recovery substantially while this effect is less pronounces in more wet sites, where soil compaction due to restoration may in some cases even slow recovery.

  14. Tramadol chronic abuse: an evidence from hair analysis by LC tandem MS.

    PubMed

    Verri, Patrizia; Rustichelli, Cecilia; Palazzoli, Federica; Vandelli, Daniele; Marchesi, Filippo; Ferrari, Anna; Licata, Manuela

    2015-01-01

    Hair analysis, as complementary matrix, has expanded across the spectrum of toxicological investigations for misuse drug monitoring. Hair has become an important matrix for drug analysis, owing to the possibility to detect target analytes for long time periods, depending on hair length. A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed for the quantitation of tramadol, a widely used centrally acting analgesic, and its main metabolites in hair (ODMT, NDMT, NOT). Hair samples were decontaminated and incubated overnight in diluted hydrochloric acid; the extracts were purified by mixed-mode solid phase cartridges and analyzed by LC-MS/MS in positive ionization mode monitoring two transitions per analyte. The procedure was fully validated in terms of linearity, limit of detection and lower limit of quantitation (LLOQ), accuracy, precision, recovery, matrix effect and selectivity. The linear regression analysis was calibrated by deuterated internal standards; for all analytes, responses were linear over the range 0.04-40.00 ng/mg hair, with R(2) values of at least 0.995. The method offered satisfactory precision (RSD < 10%), accuracy (90-110%) and recovery (> 90%) values. The found LLOQ values for tramadol and metabolites were in the range 0.010-0.030 ng/mg hair. The proposed procedure was successfully applied to quantify tramadol and metabolites in real hair samples submitted to our laboratory: three cases of tramadol assumption within the therapeutic dosage (3 × 2 segments) and one case of tramadol abuse in a binge pattern (8 segments). The ranges found for TRAM, ODMT, NDMT and NOT were markedly higher in the abuse case (63.42-107.30, 3.76-6.26, 24.88-45.66, 0.22-1.18 ng/mg hair, respectively) compared to the other case reports (3.29-20.12, 0.28-1.87, 0.45-4.32, 0.07-0.80 ng/mg, respectively); also the values of NMDT/ODMT ratio differed significantly. According to the obtained data, we hypothesized that the binge pattern may influence the metabolites' to parent drug concentration ratios; therefore this parameter could represent a target assessment tool to monitor abuse cases. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Determination of trace rare earth elements in gadolinium aluminate by inductively coupled plasma time of flight mass spectrometry

    NASA Astrophysics Data System (ADS)

    Saha, Abhijit; Deb, S. B.; Nagar, B. K.; Saxena, M. K.

    An analytical methodology was developed for the precise quantification of ten trace rare earth elements (REEs), namely, La, Ce, Pr, Nd, Sm, Eu, Tb, Dy, Ho, and Tm, in gadolinium aluminate (GdAlO3) employing an ultrasonic nebulizer (USN)-desolvating device based inductively coupled plasma mass spectrometry (ICP-MS). A microwave digestion procedure was optimized for digesting 100 mg of the refractory oxide using a mixture of sulphuric acid (H2SO4), phosphoric acid (H3PO4) and water (H2O) with 1400 W power, 10 min ramp and 60 min hold time. An USN-desolvating sample introduction system was employed to enhance analyte sensitivities by minimizing their oxide ion formation in the plasma. Studies on the effect of various matrix concentrations on the analyte intensities revealed that precise quantification of the analytes was possible with matrix level of 250 mg L- 1. The possibility of using indium as an internal standard was explored and applied to correct for matrix effect and variation in analyte sensitivity under plasma operating conditions. Individual oxide ion formation yields were determined in matrix matched solution and employed for correcting polyatomic interferences of light REE (LREE) oxide ions on the intensities of middle and heavy rare earth elements (MREEs and HREEs). Recoveries of ≥ 90% were achieved for the analytes employing standard addition technique. Three real samples were analyzed for traces of REEs by the proposed method and cross validated for Eu and Nd by isotope dilution mass spectrometry (IDMS). The results show no significant difference in the values at 95% confidence level. The expanded uncertainty (coverage factor 1σ) in the determination of trace REEs in the samples were found to be between 3 and 8%. The instrument detection limits (IDLs) and the method detection limits (MDLs) for the ten REEs lie in the ranges 1-5 ng L- 1 and 7-64 μg kg- 1 respectively.

  16. Multi-residue methods for the determination of over four hundred pesticides in solid and liquid high sucrose content matrices by tandem mass spectrometry coupled with gas and liquid chromatograph.

    PubMed

    Lozowicka, Bozena; Ilyasova, Gulzhakhan; Kaczynski, Piotr; Jankowska, Magdalena; Rutkowska, Ewa; Hrynko, Izabela; Mojsak, Patrycja; Szabunko, Julia

    2016-05-01

    For the first time three methods: matrix solid phase dispersion (MSPD), original and modified QuEChERS, with and without clean up step were studied in order to evaluate the extraction efficiency of various classes of pesticides from solid and liquid high sucrose content matrices. Determinations over four hundred pesticides were performed by gas and liquid chromatography with triple quadrupole mass spectrometry (GC/LC/MS/MS) using multiple reaction monitoring. The proposed methods were validated on sugar beets and their technological product beet molasses. In general, the recoveries obtained for the original QuEChERS and MSPD method were lower (<70%) than for the modified QuEChERS without clean up in sugar beet and with clean up in beet molasses. Among these methods, high extraction yields were achieved as recommended in SANCO/12571/2013, with repeatability of 4.4-19.2% and within-laboratory reproducibility of 7.1-18.4% for citrate QuEChERS, whereas greater ruggedness were observed for MSPD. The limit of quantification (LOQ) at (the lowest MRL=0.01mgkg(-1)e.g. for oxamyl()) or below (0.005mgkg(-1)) the regulatory maximum residue level for the pesticides were achieved. The expanded measurement uncertainty was not higher than 30% for all target analytes. Matrix effects were compared and observed for both matrices at both gas and liquid chromatography. The most compounds showed signal enhancement and it was compensated by using matrix-matched calibration and modified QuEChERS characterized lower matrix effects. The confirmation of suitability citrate QuEChERS optimized method was to use for routine testing of several dozen samples determination and residue of epoxiconazole and tebuconazole (both at 0.01mgkg(-1)) in the samples of beet molasses and cyfluthrin (0.06mgkg(-1)) in sugar beet were found. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Ion-exchange solid-phase extraction combined with liquid chromatography-tandem mass spectrometry for the determination of veterinary drugs in organic fertilizers.

    PubMed

    Zhao, Zhiyong; Zhang, Yanmei; Xuan, Yanfang; Song, Wei; Si, Wenshuai; Zhao, Zhihui; Rao, Qinxiong

    2016-06-01

    The analysis of veterinary drugs in organic fertilizers is crucial for an assessment of potential risks to soil microbial communities and human health. We develop a robust and sensitive method to quantitatively determine 19 veterinary drugs (amantadine, sulfonamides and fluoroquinolones) in organic fertilizers. The method involved a simple solid-liquid extraction step using the combination of acetonitrile and McIlvaine buffer as extraction solvent, followed by cleanup with a solid-phase extraction cartridge containing polymeric mixed-mode anion-exchange sorbents. Ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) was used to separate and detect target analytes. We particularly focused on the optimization of sample clean-up step: different diluents and dilution factors were tested. The developed method was validated in terms of linearity, recovery, precision, sensitivity and specificity. The recoveries of all the drugs ranged from 70.9% to 112.7% at three concentration levels, with the intra-day and inter-day relative standard deviation lower than 15.7%. The limits of quantification were between 1.0 and 10.0μg/kg for all the drugs. Matrix effect was minimized by matrix-matched calibration curves. The analytical method was successfully applied for the survey of veterinary drugs contamination in 20 compost samples. The results indicated that fluoroquinolones had higher incidence rate and mean concentration levels ranging from 31.9 to 308.7μg/kg compared with other drugs. We expect the method will provide the basis for risk assessment of veterinary drugs in organic fertilizers. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. A tracer experiment to study flow paths of water in a forest soil

    NASA Astrophysics Data System (ADS)

    Feyen, H.; Wunderli, H.; Wydler, H.; Papritz, A.

    1999-12-01

    This contribution discusses a tracer experiment, which was performed to study the flow paths of water in a macroporous forest soil. The experiment was performed in the framework of a study on the cycling of nitrogen in forested Prealpine catchments, in which losses of nitrate from virtually pristine areas were observed. Two soil plots with distinct micro-topography and top-soil were investigated: a well drained mor humus on a mound and a wet muck humus in a small depression. To reveal the effect of the soil horizons on the flow regime, tracers were applied both onto the soil surface and injected into the sub-soil. Tracers injected directly into the gleyic sub-soil reached the outlet (at a distance of 3.3 m) about 1000 times faster than could be expected from the saturated hydraulic conductivity of the soil matrix. Peak concentrations were observed after 18 (muck humus, tracer recovery 31%) to 70 min (mor humus, tracer recovery 40%). The peak concentration was 10 times smaller on the drier mor humus plot as compared to the muck humus. The mobile water content of the sub-soil varied between 0.5 (muck humus) and 1.3% (mor humus) of the total available soil water. The discrepancy in residence time, peak concentration and volume of mobile water between both sub-soils can be attributed to the differently structured sub-soil (longer travel distance and mixing volume in the drier mor humus). Tracers applied onto the soil surface resulted in a much slower breakthrough (tracer peaks after 400-700 min). Thus, in contrast to the sub-soil, flow through the matrix was the predominating transport process in the upper humus layers of both plots.

  19. Influence of the extracellular matrix on endogenous and transplanted stem cells after brain damage

    PubMed Central

    Roll, Lars; Faissner, Andreas

    2014-01-01

    The limited regeneration capacity of the adult central nervous system (CNS) requires strategies to improve recovery of patients. In this context, the interaction of endogenous as well as transplanted stem cells with their environment is crucial. An understanding of the molecular mechanisms could help to improve regeneration by targeted manipulation. In the course of reactive gliosis, astrocytes upregulate Glial fibrillary acidic protein (GFAP) and start, in many cases, to proliferate. Beside GFAP, subpopulations of these astroglial cells coexpress neural progenitor markers like Nestin. Although cells express these markers, the proportion of cells that eventually give rise to neurons is limited in many cases in vivo compared to the situation in vitro. In the first section, we present the characteristics of endogenous progenitor-like cells and discuss the differences in their neurogenic potential in vitro and in vivo. As the environment plays an important role for survival, proliferation, migration, and other processes, the second section of the review describes changes in the extracellular matrix (ECM), a complex network that contains numerous signaling molecules. It appears that signals in the damaged CNS lead to an activation and de-differentiation of astrocytes, but do not effectively promote neuronal differentiation of these cells. Factors that influence stem cells during development are upregulated in the damaged brain as part of an environment resembling a stem cell niche. We give a general description of the ECM composition, with focus on stem cell-associated factors like the glycoprotein Tenascin-C (TN-C). Stem cell transplantation is considered as potential treatment strategy. Interaction of transplanted stem cells with the host environment is critical for the outcome of stem cell-based therapies. Possible mechanisms involving the ECM by which transplanted stem cells might improve recovery are discussed in the last section. PMID:25191223

  20. Assessment of a fully 3D Monte Carlo reconstruction method for preclinical PET with iodine-124

    NASA Astrophysics Data System (ADS)

    Moreau, M.; Buvat, I.; Ammour, L.; Chouin, N.; Kraeber-Bodéré, F.; Chérel, M.; Carlier, T.

    2015-03-01

    Iodine-124 is a radionuclide well suited to the labeling of intact monoclonal antibodies. Yet, accurate quantification in preclinical imaging with I-124 is challenging due to the large positron range and a complex decay scheme including high-energy gammas. The aim of this work was to assess the quantitative performance of a fully 3D Monte Carlo (MC) reconstruction for preclinical I-124 PET. The high-resolution small animal PET Inveon (Siemens) was simulated using GATE 6.1. Three system matrices (SM) of different complexity were calculated in addition to a Siddon-based ray tracing approach for comparison purpose. Each system matrix accounted for a more or less complete description of the physics processes both in the scanned object and in the PET scanner. One homogeneous water phantom and three heterogeneous phantoms including water, lungs and bones were simulated, where hot and cold regions were used to assess activity recovery as well as the trade-off between contrast recovery and noise in different regions. The benefit of accounting for scatter, attenuation, positron range and spurious coincidences occurring in the object when calculating the system matrix used to reconstruct I-124 PET images was highlighted. We found that the use of an MC SM including a thorough modelling of the detector response and physical effects in a uniform water-equivalent phantom was efficient to get reasonable quantitative accuracy in homogeneous and heterogeneous phantoms. Modelling the phantom heterogeneities in the SM did not necessarily yield the most accurate estimate of the activity distribution, due to the high variance affecting many SM elements in the most sophisticated SM.

  1. Liquid chromatography/tandem mass spectrometry method for simultaneous determination of cocaine and its metabolite (-)ecgonine methyl ester in human acidified stabilized plasma samples.

    PubMed

    Liu, Yongzhen; Zheng, Bo; Strafford, Stephanie; Orugunty, Ravi; Sullivan, Michael; Gus, Jeffrey; Heidbreder, Christian; Fudala, Paul J; Nasser, Azmi

    2014-06-15

    Two simple, sensitive and rapid liquid chromatography/electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) methods (low range and high range) were developed and validated for the quantification of cocaine and its metabolite (-)ecgonine methyl ester (EME) in human acidified stabilized plasma samples. In the low range assay, cocaine and the internal standard, cocaine-D3, were extracted using a single step liquid-liquid extraction from human acidified stabilized plasma. For the high range assay, human acidified stabilized plasma containing cocaine, EME, and the internal standards, cocaine-D3 and EME-D3, was mixed with acetonitrile, and the protein precipitate was separated by centrifugation. Both cocaine and EME extracted from both assays were separated on a HILIC column and detected in positive ion mode using multiple reaction monitoring (MRM). Both methods were validated and the specificity, linearity, lower limit of quantitation (LLOQ), precision, accuracy, recoveries and stability were determined. The linear range for the low range assay was 0.01-5ng/mL for cocaine; in the high range assay values were 5-1000ng/mL for cocaine and 1-200ng/mL for EME. The correlation coefficient (R(2)) values for both assays were 0.993 or greater. The precision and accuracy for intra-day and inter-day were better than 13.0%. The recovery was above 85% and matrix effects were low with the matrix factor ranging from 0.817 to 1.10 for both analytes in both assays. The validated methods were successfully used to quantify the plasma concentrations of cocaine and EME in clinical pharmacokinetic and pharmacodynamic studies. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Permeability evolution of shale during spontaneous imbibition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chakraborty, N.; Karpyn, Z. T.; Liu, S.

    Shales have small pore and throat sizes ranging from nano to micron scales, low porosity and limited permeability. The poor permeability and complex pore connectivity of shales pose technical challenges to (a) understanding flow and transport mechanisms in such systems and, (b) in predicting permeability changes under dynamic saturation conditions. This paper presents quantitative experimental evidence of the migration of water through a generic shale core plug using micro CT imaging. In addition, in-situ measurements of gas permeability were performed during counter-current spontaneous imbibition of water in nano-darcy permeability Marcellus and Haynesville core plugs. It was seen that water blocksmore » severely reduced the effective permeability of the core plugs, leading to losses of up to 99.5% of the initial permeability in experiments lasting 30 days. There was also evidence of clay swelling which further hindered gas flow. When results from this study were compared with similar counter-current gas permeability experiments reported in the literature, the initial (base) permeability of the rock was found to be a key factor in determining the time evolution of effective gas permeability during spontaneous imbibition. With time, a recovery of effective permeability was seen in the higher permeability rocks, while becoming progressively detrimental and irreversible in tighter rocks. Finally, these results suggest that matrix permeability of ultra-tight rocks is susceptible to water damage following hydraulic fracturing stimulation and, while shut-in/soaking time helps clearing-up fractures from resident fluid, its effect on the adjacent matrix permeability could be detrimental.« less

  3. Permeability evolution of shale during spontaneous imbibition

    DOE PAGES

    Chakraborty, N.; Karpyn, Z. T.; Liu, S.; ...

    2017-01-05

    Shales have small pore and throat sizes ranging from nano to micron scales, low porosity and limited permeability. The poor permeability and complex pore connectivity of shales pose technical challenges to (a) understanding flow and transport mechanisms in such systems and, (b) in predicting permeability changes under dynamic saturation conditions. This paper presents quantitative experimental evidence of the migration of water through a generic shale core plug using micro CT imaging. In addition, in-situ measurements of gas permeability were performed during counter-current spontaneous imbibition of water in nano-darcy permeability Marcellus and Haynesville core plugs. It was seen that water blocksmore » severely reduced the effective permeability of the core plugs, leading to losses of up to 99.5% of the initial permeability in experiments lasting 30 days. There was also evidence of clay swelling which further hindered gas flow. When results from this study were compared with similar counter-current gas permeability experiments reported in the literature, the initial (base) permeability of the rock was found to be a key factor in determining the time evolution of effective gas permeability during spontaneous imbibition. With time, a recovery of effective permeability was seen in the higher permeability rocks, while becoming progressively detrimental and irreversible in tighter rocks. Finally, these results suggest that matrix permeability of ultra-tight rocks is susceptible to water damage following hydraulic fracturing stimulation and, while shut-in/soaking time helps clearing-up fractures from resident fluid, its effect on the adjacent matrix permeability could be detrimental.« less

  4. Precision, accuracy and linearity of radiometer EML 105 whole blood metabolite biosensors.

    PubMed

    Cobbaert, C; Morales, C; van Fessem, M; Kemperman, H

    1999-11-01

    The analytical performance of a new, whole blood glucose and lactate electrode system (EML 105 analyser. Radiometer Medical A/S. Copenhagen, Denmark) was evaluated. Between-day coefficients of variation were < or = 1.9% and < or = 3.1% for glucose and lactate, respectively. Recoveries of glucose were 100 +/- 10% using either aqueous or protein-based standards. Recoveries of lactate depended on the matrix, being underestimated in aqueous standards (approximately -10%) and 95-100% in standards containing 40 g/L albumin at lactate concentrations of 15 and 30 mmol/L. However, recoveries were high (up to 180%) at low lactate concentrations in protein-based standards. Carry-over, investigated according to National Clinical Chemistry Laboratory Standards EP10-T2, was negligible (alpha = 0.01). Glucose and lactate biosensors equipped with new membranes were linear up to 60 and 30 mmol/L, respectively. However, linearity fell upon daily use with increasing membrane lifetime. We conclude that the Radiometer metabolite biosensor results are reproducible and do not suffer from specimen-related carry-over. However, lactate recovery depends on the protein content and the lactate concentration.

  5. Optimized demineralization technique for the measurement of stable isotope ratios of nonexchangeable H in soil organic matter.

    PubMed

    Ruppenthal, Marc; Oelmann, Yvonne; Wilcke, Wolfgang

    2013-01-15

    To make use of the isotope ratio of nonexchangeable hydrogen (δ(2)H(n (nonexchangeable))) of bulk soil organic matter (SOM), the mineral matrix (containing structural water of clay minerals) must be separated from SOM and samples need to be analyzed after H isotope equilibration. We present a novel technique for demineralization of soil samples with HF and dilute HCl and recovery of the SOM fraction solubilized in the HF demineralization solution via solid-phase extraction. Compared with existing techniques, organic C (C(org)) and organic N (N(org)) recovery of demineralized SOM concentrates was significantly increased (C(org) recovery using existing techniques vs new demineralization method: 58% vs 78%; N(org) recovery: 60% vs 78%). Chemicals used for the demineralization treatment did not affect δ(2)H(n) values as revealed by spiking with deuterated water. The new demineralization method minimized organic matter losses and thus artificial H isotope fractionation, opening up the opportunity to use δ(2)H(n) analyses of SOM as a new tool in paleoclimatology or geospatial forensics.

  6. The relative effects of habitat loss and fragmentation on population genetic variation in the red-cockaded woodpecker (Picoides borealis).

    PubMed

    Bruggeman, Douglas J; Wiegand, Thorsten; Fernández, Néstor

    2010-09-01

    The relative influence of habitat loss, fragmentation and matrix heterogeneity on the viability of populations is a critical area of conservation research that remains unresolved. Using simulation modelling, we provide an analysis of the influence both patch size and patch isolation have on abundance, effective population size (N(e)) and F(ST). An individual-based, spatially explicit population model based on 15 years of field work on the red-cockaded woodpecker (Picoides borealis) was applied to different landscape configurations. The variation in landscape patterns was summarized using spatial statistics based on O-ring statistics. By regressing demographic and genetics attributes that emerged across the landscape treatments against proportion of total habitat and O-ring statistics, we show that O-ring statistics provide an explicit link between population processes, habitat area, and critical thresholds of fragmentation that affect those processes. Spatial distances among land cover classes that affect biological processes translated into critical scales at which the measures of landscape structure correlated best with genetic indices. Therefore our study infers pattern from process, which contrasts with past studies of landscape genetics. We found that population genetic structure was more strongly affected by fragmentation than population size, which suggests that examining only population size may limit recognition of fragmentation effects that erode genetic variation. If effective population size is used to set recovery goals for endangered species, then habitat fragmentation effects may be sufficiently strong to prevent evaluation of recovery based on the ratio of census:effective population size alone.

  7. Physical aging in graphite/epoxy composites

    NASA Technical Reports Server (NTRS)

    Kong, E. S. W.

    1983-01-01

    Sub-Tg annealing has been found to affect the properties of graphite/epoxy composites. The network epoxy studied was based on the chemistry of tetraglycidyl 4,4'-diamino-diphenyl methane (TGDDM) crosslinked by 4,4'-diamino-diphenyl sulfone (DDS). Differential scanning calorimetry, thermal mechanical analysis, and solid-state cross-polarized magic-angle-spinning nuclear magnetic resonance spectroscopy have been utilized in order to characterize this process of recovery towards thermodynamic equilibrium. The volume and enthalpy recovery as well as the 'thermoreversibility' aspects of the physical aging are discussed. This nonequilibrium and time-dependent behavior of network epoxies are considered in view of the increasingly wide applications of TGDDM-DDS epoxies as matrix materials of structural composites in the aerospace industry.

  8. Autonomic healing of acrylic bone cement.

    PubMed

    Gladman, A Sydney; Celestine, Asha-Dee N; Sottos, Nancy R; White, Scott R

    2015-01-28

    Self-healing in orthopedic bone cement is demonstrated with a novel thermoplastic solvent-bonding approach. Low toxicity solvent-filled microcapsules, embedded in a commercial acrylic bone cement matrix, enable recovery of up to 80% of the virgin fracture toughness of the cement at room and body temperature conditions without external stimuli or human intervention. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Microorganisms in inorganic chemical analysis.

    PubMed

    Godlewska-Zyłkiewicz, Beata

    2006-01-01

    There are innumerable strains of microbes (bacteria, yeast and fungi) that degrade or transform chemicals and compounds into simpler, safer or less toxic substances. These bioprocesses have been used for centuries in the treatment of municipal wastes, in wine, cheese and bread making, and in bioleaching and metal recovery processes. Recent literature shows that microorganisms can be also used as effective sorbents for solid phase extraction procedures. This review reveals that fundamental nonanalytical studies on the parameters and conditions of biosorption processes and on metal-biomass interactions often result in efficient analytical procedures and biotechnological applications. Some selected examples illustrate the latest developments in the biosorption of metals by microbial biomass, which have opened the door to the application of microorganisms to analyte preconcentration, matrix separation and speciation analysis.

  10. [Determination of trace cobalt in human urine by graphite furnace atomic absorption spectrometr].

    PubMed

    Zhong, L X; Ding, B M; Jiang, D; Liu, D Y; Yu, B; Zhu, B L; Ding, L

    2016-05-20

    To establish a method to determine cobalt in human urine by graphite furnace atomic absorption spectrometry. Urine with 2% nitric acid diluted two-fold, to quantify the curve, graphite furnace atomic absorption spectrometric detection. Co was linear within 2.5~40.0 ng/ml with r>0.999. Spike experiment showed that Co received good recovery rate, which was 90.8%~94.8%. Intra-assay precisions were 3.2%~5.1% for Co, inter-assay precisions were 4.4%~5.2% for Co. The method by using graphite furnace atomic absorption spectrometr to determine urine Co was fast, accurate and with low matrix effect. It could meet the requirement in GBZ/T 210.5-2008.

  11. Direct recovery of mean gravity anomalies from satellite to satellite tracking

    NASA Technical Reports Server (NTRS)

    Hajela, D. P.

    1974-01-01

    The direct recovery was investigated of mean gravity anomalies from summed range rate observations, the signal path being ground station to a geosynchronous relay satellite to a close satellite significantly perturbed by the short wave features of the earth's gravitational field. To ensure realistic observations, these were simulated with the nominal orbital elements for the relay satellite corresponding to ATS-6, and for two different close satellites (one at about 250 km height, and the other at about 900 km height) corresponding to the nominal values for GEOS-C. The earth's gravitational field was represented by a reference set of potential coefficients up to degree and order 12, considered as known values, and by residual gravity anomalies obtained by subtracting the anomalies, implied by the potential coefficients, from their terrestrial estimates. It was found that gravity anomalies could be recovered from strong signal without using any a-priori terrestrial information, i.e. considering their initial values as zero and also assigning them a zero weight matrix. While recovering them from weak signal, it was necessary to use the a-priori estimate of the standard deviation of the anomalies to form their a-priori diagonal weight matrix.

  12. Tissue plasminogen activator (tPA) and matrix metalloproteinases in the pathogenesis of stroke: therapeutic strategies.

    PubMed

    Adibhatla, Rao Muralikrishna; Hatcher, James F

    2008-06-01

    Today there exists only one FDA-approved treatment for ischemic stroke; i.e., the serine protease tissue-type plasminogen activator (tPA). In the aftermath of the failed stroke clinical trials with the nitrone spin trap/radical scavenger, NXY-059, a number of articles raised the question: are we doing the right thing? Is the animal research truly translational in identifying new agents for stroke treatment? This review summarizes the current state of affairs with plasminogen activators in thrombolytic therapy. In addition to therapeutic value, potential side effects of tPA also exist that aggravate stroke injury and offset the benefits provided by reperfusion of the occluded artery. Thus, combinational options (ultrasound alone or with microspheres/nanobubbles, mechanical dissociation of clot, activated protein C (APC), plasminogen activator inhibitor-1 (PAI-1), neuroserpin and CDP-choline) that could offset tPA toxic side effects and improve efficacy are also discussed here. Desmoteplase, a plasminogen activator derived from the saliva of Desmodus rotundus vampire bat, antagonizes vascular tPA-induced neurotoxicity by competitively binding to low-density lipoprotein related-receptors (LPR) at the blood-brain barrier (BBB) interface, minimizing the tPA uptake into brain parenchyma. tPA can also activate matrix metalloproteinases (MMPs), a family of endopeptidases comprised of 24 mammalian enzymes that primarily catalyze the turnover and degradation of the extracellular matrix (ECM). MMPs have been implicated in BBB breakdown and neuronal injury in the early times after stroke, but also contribute to vascular remodeling, angiogenesis, neurogenesis and axonal regeneration during the later repair phase after stroke. tPA, directly or by activation of MMP-9, could have beneficial effects on recovery after stroke by promoting neurovascular repair through vascular endothelial growth factor (VEGF). However, any treatment regimen directed at MMPs must consider their pleiotropic nature and the likelihood of either beneficial or detrimental effects that might depend on the timing of the treatment in relation to the stage of brain injury.

  13. Impact of quality parameters on the recovery of putrescine and cadaverine in fish using methanol-hydrochloric acid solvent extraction.

    PubMed

    Richard, Nicole L; Pivarnik, Lori F; Ellis, P Christopher; Lee, Chong M

    2011-01-01

    Methanol (MeOH) extraction by AOAC Official Method 996.07 has resulted in low amine recoveries in fresh fish tissue. Addition of 25% 0.4 M HCl to the 75% methanol-water extraction solvent resulted in higher recoveries of putrescine and cadaverine. Average putrescine recovery increased from 55 to 92% in flounder, scup, bluefish, and salmon; from 92 to 98% in mackerel; and from 83 to 107% in processed mackerel. Average cadaverine recovery increased from 57 to 95% in flounder, scup, bluefish, and salmon; from 91 to 97% in mackerel; and from 92 to 108% in processed mackerel. Fish stored on ice for 12 days also showed differences between background concentrations determined with the two solvents. However, the values decreased with storage time, indicating that degradation of the protein matrix may cause more comparable measurements between the two solvents. However, consistently higher putrescine and cadaverine measurements were determined using MeOH-HCl. Although significant differences in the extraction of amines from the high-fat fish tissue were not seen between MeOH and MeOH-HCl, it would be ideal to have one solvent for biogenic amine extraction. This study confirms that MeOH-HCl is a better solvent for complete extraction and recovery of putrescine and cadaverine in fresh and processed fish tissues.

  14. Determination of acidic pharmaceuticals and potential endocrine disrupting compounds in wastewaters and spring waters by selective elution and analysis by gas chromatography-mass spectrometry.

    PubMed

    Gibson, Richard; Becerril-Bravo, Elías; Silva-Castro, Vanessa; Jiménez, Blanca

    2007-10-26

    Although the trend in development of analytical methods for emerging contaminants is towards reduced sample preparation and increased detector selectivity, there are still benefits from removal of matrix material during sample preparation. This paper describes a simple method for acidic pharmaceuticals and a range of potential endocrine disrupting compounds in untreated wastewaters and spring waters. It is based on separation of the two classes during elution from the extraction cartridge with final analysis by gas chromatography-mass spectrometry. 3,4-D was used as the recovery standard for the acids while 4-n-nonylphenol and [2H4]estrone were used for the endocrine disrupters; mean recoveries varied between 89% and 111%. The method was also extensively validated by fortification with the target compounds. Recoveries of acids were from 68% to 97% with relative standard deviations generally less than 10% and recoveries of endocrine disrupters were 68-109% with relative standard deviations less than 20%. Detection limits varied from 0.005 to 1 ng/L in spring water, and from 0.5 to 100 ng/L in untreated wastewater. Concentrations of the analytes in the wastewater ranged from 0.018 to 22.4 microg/L. Values were comparable to reported data, although concentrations were generally relatively high, probably because of a lack of treatment. Triclosan, phthalates, estrone, 17beta-estradiol, ibuprofen, and naproxen were present in the spring water from aquifers recharged indirectly with this wastewater after its use for irrigation; concentrations ranged from 0.01 to 25.0 ng/L. The much lower concentrations compared to wastewater indicate effective removal processes on passage through the soil and subsoil.

  15. Matrix effect on the performance of headspace solid phase microextraction method for the analysis of target volatile organic compounds (VOCs) in environmental samples.

    PubMed

    Higashikawa, Fábio S; Cayuela, Maria Luz; Roig, Asunción; Silva, Carlos A; Sánchez-Monedero, Miguel A

    2013-11-01

    Solid phase microextraction (SPME) is a fast, cheap and solvent free methodology widely used for environmental analysis. A SPME methodology has been optimized for the analysis of VOCs in a range of matrices covering different soils of varying textures, organic matrices from manures and composts from different origins, and biochars. The performance of the technique was compared for the different matrices spiked with a multicomponent VOC mixture, selected to cover different VOC groups of environmental relevance (ketone, terpene, alcohol, aliphatic hydrocarbons and alkylbenzenes). VOC recovery was dependent on the nature itself of the VOC and the matrix characteristics. The SPME analysis of non-polar compounds, such as alkylbenzenes, terpenes and aliphatic hydrocarbons, was markedly affected by the type of matrix as a consequence of the competition for the adsorption sites in the SPME fiber. These non-polar compounds were strongly retained in the biochar surfaces limiting the use of SPME for this type of matrices. However, this adsorption capacity was not evident when biochar had undergone a weathering/aging process through composting. Polar compounds (alcohol and ketone) showed a similar behavior in all matrices, as a consequence of the hydrophilic characteristics, affected by water content in the matrix. SPME showed a good performance for soils and organic matrices especially for non-polar compounds, achieving a limit of detection (LD) and limit of quantification (LQ) of 0.02 and 0.03 ng g(-1) for non-polar compounds and poor extraction for more hydrophilic and polar compounds (LD and LQ higher 310 and 490 ng g(-1)). The characteristics of the matrix, especially pH and organic matter, had a marked impact on SPME, due to the competition of the analytes for active sites in the fiber, but VOC biodegradation should not be discarded in matrices with active microbial biomass. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. Development and validation of a solid-phase extraction method using anion exchange sorbent for the analysis of cannabinoids in plasma and serum by gas chromatography-mass spectrometry.

    PubMed

    Gasse, Angela; Pfeiffer, Heidi; Köhler, Helga; Schürenkamp, Jennifer

    2016-07-01

    The aim of this work was to develop and validate a solid-phase extraction (SPE) method for the analysis of cannabinoids with emphasis on a very extensive and effective matrix reduction in order to ensure constant good results in selectivity and sensitivity regardless of the applied measuring technology. This was obtained by the use of an anion exchange sorbent (AXS) and the purposive ionic interaction between matrix components and this sorbent material. In a first step, the neutral cannabinoids ∆9-tetrahydrocannabinol (THC) and 11-hydroxy-∆9-tetrahydrocannabinol (11-OH-THC) were eluted, leaving 11-nor-9-carboxy-∆9-tetrahydrocannabinol (THC-COOH) and the main interfering matrix components bound to the AXS. In a second step, exploiting differences in pH and polarity, it was possible to separate matrix components and THC-COOH, thereby yielding a clean elution of THC-COOH into the same collecting tube as THC and 11-OH-THC. Even when using a simple measuring technology like gas chromatography with single quadrupole mass spectrometry, this two-step elution allows for an obvious decrease in number and intensity of matrix interference in the chromatogram. Hence, in both plasma and serum, the AXS extracts resulted in very good selectivity. Limits of detection and limits of quantification were below 0.25 and 0.35 ng/mL for the neutral cannabinoids in both matrices, 2.0 and 3.0 ng/mL in plasma and 1.6 and 3.3 ng/mL in serum for THC-COOH. The recoveries were ≥79.8 % for all analytes. Interday and intraday imprecisions ranged from 0.8 to 6.1 % relative standard deviation, and accuracy bias ranged from -12.6 to 3.6 %.

  17. Collagen nerve guides for surgical repair of brachial plexus birth injury.

    PubMed

    Ashley, William W; Weatherly, Trisha; Park, Tae Sung

    2006-12-01

    Standard brachial plexus repair techniques often involve autologous nerve graft placement and neurotization. However, when performed to treat severe injuries, this procedure can sometimes yield poor results. Moreover, harvesting the autologous graft is time-consuming and exposes the patient to additional surgical risks. To improve surgical outcomes and reduce surgical risks associated with autologous nerve graft retrieval and placement, the authors use collagen matrix tubes (Neurogen) instead of autologous nerve graft material. Between 1991 and 2005, the authors surgically treated 65 infants who had suffered brachial plexus injury at birth. During this time, seven patients were treated using collagen matrix tubes (Neurogen). This study is a retrospective analysis of the initial five patients who were treated using the tubes. Two patients underwent tube placement recently and were excluded from the analysis because of the inadequate follow-up period. Four of the five patients experienced a good recovery (motor scale composite [MSC] > 0.6), and three exhibited an excellent recovery (MSC > 0.75) at 2 years postoperatively. The MSC improved by an average of 69 and 78% at 1 and 2 years, respectively. The movement scores improved to greater than or equal to 50% range of motion in most patients, and the contractures were usually mild or moderate. Follow-up physical and occupational therapy evaluations confirm these patients' functional status. When last seen, four of five of these children could feed and dress themselves. Technically, the use of the collagen matrix tubes was straightforward and efficient, and there were no complications. The outcomes in this small series are encouraging.

  18. Mortality sensitivity in life-stage simulation analysis: A case study of southern sea otters

    USGS Publications Warehouse

    Gerber, L.R.; Tinker, M.T.; Doak, D.F.; Estes, J.A.; Jessup, David A.

    2004-01-01

    Currently, there are no generally recognized approaches for linking detailed mortality and pathology data to population-level analyses of extinction risk. We used a combination of analytical and simulation-based analyses to examine 20 years of age- and sex-specific mortality data for southern sea otters (Enhydra lutris), and we applied results to project the efficacy of alternative conservation strategies. Population recovery of the southern sea otter has been slow (rate of population increase ?? = 1.05) compared to other recovering populations (?? = 1.17-1.20), and the population declined (?? = 0.975) between 1995 and 1999. Age-based Leslie matrices were developed to explore explanations for the slow recovery and recent decline in the southern sea other population. An elasticity analysis was performed to predict effects of proportional changes in stage-specific reproductive or survival rates on the rate of population increase. A life-stage simulation analysis (LSA) was developed to evaluate the impact of changing age- and cause-specific mortality rates on ??. The information used to develop these models was derived from death assemblage, pathology, and live population census data to examine the sensitivity of sea otter population growth to different sources of mortality (e.g., disease and starvation, direct human take [fisheries, gun shot, boat strike, oil pollution], mating trauma and intraspecific aggression, shark bites, and unknown). We used resampling simulations to generate random combinations of vital rates for a large number of matrix replicates and drew on these to estimate potential effects of mortality sources on population growth (??). Our analyses suggest management actions that are likely and unlikely to promote recovery of the southern sea otter and more broadly indicate a methodology to better utilize cause-of-death data in conservation decision-making.

  19. New sorbent in the dispersive solid phase extraction step of quick, easy, cheap, effective, rugged, and safe for the extraction of organic contaminants in drinking water treatment sludge.

    PubMed

    Cerqueira, Maristela B R; Caldas, Sergiane S; Primel, Ednei G

    2014-04-04

    Recent studies have shown a decrease in the concentration of pesticides, pharmaceuticals and personal care products (PCPs) in water after treatment. A possible explanation for this phenomenon is that these compounds may adhere to the sludge; however, investigation of these compounds in drinking water treatment sludge has been scarce. The sludge generated by drinking water treatment plants during flocculation and decantation steps should get some special attention not only because it has been classified as non-inert waste but also because it is a very complex matrix, consisting essentially of inorganic (sand, argil and silt) and organic (humic substances) compounds. In the first step of this study, three QuEChERS methods were used, and then compared, for the extraction of pesticides (atrazine, simazine, clomazone and tebuconazole), pharmaceuticals (amitriptyline, caffeine, diclofenac and ibuprofen) and PCPs (methylparaben, propylparaben, triclocarban and bisphenol A) from drinking water treatment sludge. Afterwards, the study of different sorbents in the dispersive solid phase extraction (d-SPE) step was evaluated. Finally, a new QuEChERS method employing chitin, obtained from shrimp shell waste, was performed in the d-SPE step. After having been optimized, the method showed limits of quantification (LOQ) between 1 and 50 μg kg(-1) and the analytical curves showed r values higher than 0.98, when liquid chromatography tandem mass spectrometry was employed. Recoveries ranged between 50 and 120% with RSD≤15%. The matrix effect was evaluated and compensated with matrix-matched calibration. The method was applied to drinking water treatment sludge samples and methylparaben and tebuconazole were found in concentration

  20. Miniaturized QuEChERS based methodology for multiresidue determination of pesticides in odonate nymphs as ecosystem biomonitors.

    PubMed

    Jesús, Florencia; Hladki, Ricardo; Gérez, Natalia; Besil, Natalia; Niell, Silvina; Fernández, Grisel; Heinzen, Horacio; Cesio, María Verónica

    2018-02-01

    The impacts of the modern, agrochemicals based agriculture that threatens the overall systems sustainability, need to be monitored and evaluated. Seeking for agroecosystems monitors, the present article focus in the occurrence and abundance of aquatic macroinvertebrates, that have been frequently used as bioindicators of water quality due to their relationship with land use. Some of these organisms are on the top of the food chain, where bioaccumulation and biomagnification processes can be observed, and they can turn into secondary pollution sources of systems and terrestrial organisms as well. Odonate nymphs, which belong to the functional group of predators, were selected for this study. A methodology to determine 73 pesticide residues in odonate nymphs by LC-MS/MS and GC-MS/MS was developed. A QuEChERS sample preparation strategy was adapted. As it is complex to obtain samples especially in disturbed ecosystems, the method was minimized to a sample size of 200mg of fresh nymphs. The method was validated and good recoveries (71-120%) with RSDs below 20% for the majority of the studied pesticides at least at two of the assayed levels 1, 10 and 50µgkg -1 were obtained. For 32 analytes the limit of quantitation was 1µgkg -1 and 10µgkg -1 for the others. The lineal range was observed between 1-100µgkg -1 in matrix-matched and solvent calibration curves for most of the assessed pesticides. LC-MS/MS matrix effects were evaluated, 40% of the analytes presented low or no signal suppression. Only flufenoxuron presented high matrix effects. The obtained methodology is adequate for pesticide multiresidue analysis in aquatic macroinvertebrates (odonates) aiming to contribute to the ecological state evaluation of freshwater ecosystems. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Validation of a liquid chromatography-tandem mass spectrometry method for the simultaneous determination of sulfonamides, trimethoprim and dapsone in muscle, egg, milk and honey.

    PubMed

    Varenina, Ivana; Bilandžić, Nina; Kolanović, Božica Solomun; Božić, Đurđica; Sedak, Marija; Đokić, Maja; Varga, Ines

    2016-01-01

    A quantitative multi-residue method that includes 13 sulfonamides, trimethoprim and dapsone was developed and validated according to Commission Decision 2002/657/EC for muscle, milk egg and honey samples. For all matrices, the same extraction procedure was used. Samples were extracted with an acetone/dichloromethane mixture and cleaned up on aromatic sulfonic acid (SO3H) SPE cartridges. After elution and concentration steps, analytes were identified and quantified by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Data were acquired according to the multiple reaction-monitoring approach (MRM) and analytes were quantified both by the isotope dilution and the matrix-matched approaches calculating the response factors for the scanned product ions. The developed method shows good linearity, specificity, precision (repeatability and within-laboratory reproducibility), and trueness. Estimated CCβ for sulfonamides ranged between 5.6 and 8.2 µg kg(-1) for eggs, between 11.1 and 69.9 µg kg(-1) for milk, between 64.7 and 87.9 µg kg(-1) for muscle, and between 2.7 and 5.3 µg kg(-1) for honey. CCβ values for dapsone were 3.1, 0.6, 0.7 and 1.5 µg kg(-1) and for trimethoprim were 3.1, 6.7, 81.7 and 3.0 µg kg(-1) calculated for eggs, milk, muscle and honey, respectively. Recovery for all matrices was in the range from 89.1% and 109.7%. In matrix effect testing, no significant deviations were found between different samples of muscle and milk; however, a matrix effect was observed when testing different types of honey. The validation results demonstrate that the method is suitable for routine veterinary drug analysis and confirmation of suspect samples.

  2. Demographic responses of Pinguicula ionantha to prescribed fire: a regression-design LTRE approach.

    PubMed

    Kesler, Herbert C; Trusty, Jennifer L; Hermann, Sharon M; Guyer, Craig

    2008-06-01

    This study describes the use of periodic matrix analysis and regression-design life table response experiments (LTRE) to investigate the effects of prescribed fire on demographic responses of Pinguicula ionantha, a federally listed plant endemic to the herb bog/savanna community in north Florida. Multi-state mark-recapture models with dead recoveries were used to estimate survival and transition probabilities for over 2,300 individuals in 12 populations of P. ionantha. These estimates were applied to parameterize matrix models used in further analyses. P. ionantha demographics were found to be strongly dependent on prescribed fire events. Periodic matrix models were used to evaluate season of burn (either growing or dormant season) for fire return intervals ranging from 1 to 20 years. Annual growing and biannual dormant season fires maximized population growth rates for this species. A regression design LTRE was used to evaluate the effect of number of days since last fire on population growth. Maximum population growth rates calculated using standard asymptotic analysis were realized shortly following a burn event (<2 years), and a regression design LTRE showed that short-term fire-mediated changes in vital rates translated into observed increases in population growth. The LTRE identified fecundity and individual growth as contributing most to increases in post-fire population growth. Our analyses found that the current four-year prescribed fire return intervals used at the study sites can be significantly shortened to increase the population growth rates of this rare species. Understanding the role of fire frequency and season in creating and maintaining appropriate habitat for this species may aid in the conservation of this and other rare herb bog/savanna inhabitants.

  3. Functional characterization of optimized acellular peripheral nerve graft in a rat sciatic nerve injury model.

    PubMed

    Nagao, Ryan J; Lundy, Scott; Khaing, Zin Z; Schmidt, Christine E

    2011-07-01

    Acellular grafts are a viable option for use in nerve reconstruction surgeries. Recently, our lab created a novel optimized decellularization procedure that removes immunological material while leaving the majority of the extracellular matrix structure intact. The optimized acellular (OA) graft has been shown to elicit an immune response equal to or less than that elicited by the isograft, the analog of the autograft in the rat model. We investigated the performance of the OA graft to provide functional recovery in a long-term study. We performed a long-term functional regeneration evaluation study using the sciatic functional index to quantify recovery of Lewis rats at regular time intervals for up to 52 weeks after graft implantation following 1 cm sciatic nerve resection. OA grafts were compared against other decellularized methods (Sondell treatment and thermal decellularization), as well as the isograft and primary neurorrhaphy. The OA graft supported comparable functional recovery to the isograft and superior regeneration to thermal and Sondell decellularization methods. Furthermore, the OA graft promoted early recovery to a greater degree compared to acellular grafts obtained using either the thermal or the Sondell methods. Equivalent functional recovery to the isograft suggests that the OA nerve graft may be a future clinical alternative to the current autologous tissue graft.

  4. Resolution of matrix effects on analysis of total and methyl mercury in aqueous samples from the Florida Everglades

    USGS Publications Warehouse

    Olson, M.L.; Cleckner, L.B.; Hurley, J.P.; Krabbenhoft, D.P.; Heelan, T.W.

    1997-01-01

    Aqueous samples from the Florida Everglades present several problems for the analysis of total mercury (HgT) and methyl mercury (MeHg). Constituents such as dissolved organic carbon (DOC) and sulfide at selected sites present particular challenges due to interferences with standard analytical techniques. This is manifested by 1) the inability to discern when bromine monochloride (BrCl) addition is sufficient for sample oxidation for HgT analysis; and 2) incomplete spike recoveries using the distillation/ethylation technique for MeHg analysis. Here, we suggest ultra-violet (UV) oxidation prior to addition of BrCl to ensure total oxidation of DOC prior to HgT analysis and copper sulfate (CuSO4) addition to aid in distillation in the presence of sulfide for MeHg analysis. Despite high chloride (Cl-) levels, we observed no effects on MeHg distillation/ethylation analyses. ?? Springer-Verlag 1997.

  5. The effects of physical aging at elevated temperatures on the viscoelastic creep on IM7/K3B

    NASA Technical Reports Server (NTRS)

    Gates, Thomas S.; Feldman, Mark

    1994-01-01

    Physical aging at elevated temperature of the advanced composite IM7/K3B was investigated through the use of creep compliance tests. Testing consisted of short term isothermal, creep/recovery with the creep segments performed at constant load. The matrix dominated transverse tensile and in-plane shear behavior were measured at temperatures ranging from 200 to 230 C. Through the use of time based shifting procedures, the aging shift factors, shift rates and momentary master curve parameters were found at each temperature. These material parameters were used as input to a predictive methodology, which was based upon effective time theory and linear viscoelasticity combined with classical lamination theory. Long term creep compliance test data was compared to predictions to verify the method. The model was then used to predict the long term creep behavior for several general laminates.

  6. Reducing operating costs for struvite formation with a carbon dioxide stripper.

    PubMed

    Fattah, K P; Sabrina, N; Mavinic, D S; Koch, F A

    2008-01-01

    One of the major operational costs of phosphorus recovery as struvite is the cost of caustic chemical that is added to maintain a desired level of operative pH. A study was conducted at the Lulu Island Wastewater Treatment Plant (LIWWTP), Richmond, BC, using a struvite crystallizer and a cascade stripper designed at the University of British Columbia (UBC). The stripper was tested under different operating conditions to determine the effectiveness of CO(2) stripping in increasing the pH of the water matrix and thereby reducing caustic chemical use. This reduction is expected to reduce the operational costs of struvite production. Throughout the project, a high percentage (90%) of phosphorus removal was achieved under each condition. The cascade stripper was very effective in saving caustic usage, ranging from 35% to 86%, depending on the operating conditions. However, the stripper showed relatively poor performance regarding ammonia stripping. Copyright IWA Publishing 2008.

  7. Determination of pesticides in coconut (Cocos nucifera Linn.) water and pulp using modified QuEChERS and LC-MS/MS.

    PubMed

    Ferreira, Jordana Alves; Ferreira, Joana Maria Santos; Talamini, Viviane; Facco, Janice de Fátima; Rizzetti, Tiele Medianeira; Prestes, Osmar Damian; Adaime, Martha Bohrer; Zanella, Renato; Bottoli, Carla Beatriz Grespan

    2016-12-15

    The use of pesticides is directly linked to improvements in productivity and to the preservation of coconut palms. However pesticide analysis is necessary to determine whether pesticide residues in the food products containing coconut are within the maximum residue limits (MRLs), ensuring the quality of these products. This work aimed to develop a method for multiresidue determination of ten pesticides in coconut water and pulp using QuEChERS and LC-MS/MS. The method was effective in terms of selectivity, linearity, matrix effect, accuracy and precision, providing LOD of 3μgkg(-1), LOQ of 10μgkg(-1) and recoveries between 70 and 120% with RSD lower than 20%. The developed method was applied to 36 samples in which residues of carbendazim, carbofuran, cyproconazole and thiabendazole were found below the LOQ in coconut water and pulp. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Qualitative and quantitative measurement of cannabinoids in cannabis using modified HPLC/DAD method.

    PubMed

    Patel, Bhupendra; Wene, Daniel; Fan, Zhihua Tina

    2017-11-30

    This study presents an accurate and high throughput method for the quantitative determination of various cannabinoids in cannabis plant material using high pressure liquid chromatography (HPLC) with a diode array detector (DAD). Sample extraction and chromatographic analysis conditions for the measurement of cannabinoids in the complex cannabis plant material matrix were optimized. The Agilent Poroshell 120 SB-C18 column provided high resolution for all target analytes with a short run time (10minutes) given the core shell technology. The aqueous buffer mobile phase was optimized with ammonium acetate at pH 4.75. The change in the mobile phase and the new column ensured a separation between cannabidiol (CBD and cannabigerol (CBG) along with cannabigerol and tetrahydrocannabinolic acid (THCA), which were not well separated by previous publications, improved buffering capacity, and provided analytical performance stability. Moreover, baseline drifting was significantly minimized by the use of a low concentration buffer solution (25mM ammonium acetate). In addition, evaporation and reconstitution of the sample residue with a methanol-organic pure (OP) water solution (65:35) significantly reduced the matrix interference. The modified extraction produced good recoveries (>91%) for each of the eight cannabinoids. The optimized method was validated for specificity, linearity, sensitivity, precision, accuracy, and stability. The combined relative standard deviation (%RSD) for intra-day and inter-day precision for all eight analytes varied from 2.5% to 5.2% and 0.28% to 5.5%, respectively. The %RSD for the repeatability study varied from 1.1% to 5.5%. The recoveries from spiked cannabis matrix samples were greater than 90% for all analytes, except delta-8-tetrahydrocannabinol (Δ 8 -THC), which was 80%. The recoveries varied from 81% to 107% with a precision of 0.7-8.1%RSD. Delta-9-tetrahydrocannabinol (Δ 9 -THC) in all of the cannabis samples (n=635) was less than 10%, which is in compliance with the NJ Medicinal Marijuana regulation. Analysis of samples from two cultivars, which included ten individual samples, four composite samples, seven calibration standards, and four quality control standards, can be performed within 24hours by this high throughput method. Published by Elsevier B.V.

  9. An insight into the determination of trace levels of benzodiazepines in biometric systems: Use of crab shell powder as an environmentally friendly biosorbent.

    PubMed

    Samadi, Fatemeh; Sarafraz-Yazdi, Ali; Es'haghi, Zarrin

    2018-05-30

    A vortex assisted dispersive solid phase extraction approach (VADSPE) based on crab shell powder as biodegradable and biocompatible μ-sorbent was developed for simultaneous analysis of three benzodiazepines (BZPs): Oxazepam, Flurazepamand Diazepam, in biological matrixes included blood, nail, hair and urine samples. The effective parameters in VADSPE process, including the volume of uptake solvent, the dosage of sorbent, extraction time and back extraction time, were optimized using response surface methodology(RSM) based on central composite design(CCD). The suggested technique allows successful trapping of BZPs in a single-step extraction. Under the optimized extraction conditions, the proposed approach was exhibited low limits of detection (0.003-1.2 μg·mL -1 ), an acceptable linearity (0.04-20 μg·mL -1 ). Method performance was assessed by recovery experiments at spiking levels of 10 μg·mL -1 (n = 5) for BZPs in blood, nail, hair and urine samples. Relative recoveries were determined by HPLC, which were between 36%and 95.6%. Copyright © 2018. Published by Elsevier B.V.

  10. Speciation evolution of zinc and copper during pyrolysis and hydrothermal carbonization treatments of sewage sludges

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, Rixiang; Zhang, Bei; Saad, Emily M.

    Thermal and hydrothermal treatments are promising techniques for sewage sludge management that can potentially facilitate safe waste disposal, energy recovery, and nutrient recovery/recycling. Content and speciation of heavy metals in the treatment products affect the potential environmental risks upon sludge disposal and/or application of the treatment products. Therefore, it is important to study the speciation transformation of heavy metals and the effects of treatment conditions. By combining synchrotron X-ray spectroscopy/microscopy analysis and sequential chemical extraction, this study systematically characterized the speciation of Zn and Cu in municipal sewage sludges and their chars derived from pyrolysis (a representative thermal treatment technique)more » and hydrothermal carbonization (HTC; a representative hydrothermal treatment technique). Spectroscopy analysis revealed enhanced sulfidation of Zn and Cu by anaerobic digestion and HTC treatments, as compared to desulfidation by pyrolysis. Overall, changes in the chemical speciation and matrix properties led to reduced mobility of Zn and Cu in the treatment products. These results provide insights into the reaction mechanisms during pyrolysis and HTC treatments of sludges and can help evaluate the environmental/health risks associated with the metals in the treatment products.« less

  11. Determination of heavy metals by ICP-OES and F-AAS after preconcentration with 2,2'-bipyridyl and erythrosine.

    PubMed

    Feist, Barbara; Mikula, Barbara; Pytlakowska, Katarzyna; Puzio, Bozena; Buhl, Franciszek

    2008-04-15

    The applicability of 2,2'-bipyridyl and erythrosine co-precipitation method for the separation and preconcentration of some heavy metals, such as Cd, Co, Cu, Ni, Pb and Zn in actual samples for their determination by ICP-OES and F-AAS was studied. Experimental conditions influencing the recovery of the investigated metals, such as pH, molar ratio of 2,2'-bipyridyl to erythrosine, the effect of time on co-precipitation were optimized. The analytical characteristics of the method (e.g. limit of detection, sensitivity, linear range and preconcentration factor) were obtained. The limits of detection LOD (ng mL(-1)) of the ICP-OES (F-AAS) method were: Cd: 4.0 (7.75), Co: 3.1 (57.2), Cu: 18 (10.3), Ni 21.3 (32.8), Pb: 35.9 (29.2) and Zn: 10.2 (6.90). The recovery of all the elements tested was more than 93%. The influence of inorganic matrix was examined. The proposed method was applied to determination of Cd, Co, Cu, Ni, Pb and Zn in vegetables and certified reference material (NCS ZC85006 Tomato).

  12. Electroactive Shape Memory Property of a Cu-decorated CNT Dispersed PLA/ESO Nanocomposite

    PubMed Central

    Alam, Javed; Khan, Aslam; Alam, Manawwer; Mohan, Raja

    2015-01-01

    Shape memory polymer (SMP) nanocomposites with a fast electro-actuation speed were prepared by dispersing Cu-decorated carbon nanotubes (CNTs) (Cu-CNTs, 1 wt %, 2 wt %, and 3 wt %) in a polylactic acid (PLA)/epoxidized soybean oil (ESO) blend matrix. The shape memory effect (SME) induced by an electrical current was investigated by a fold-deploy “U”-shape bending test. In addition, the Cu-CNT dispersed PLA/ESO nanocomposite was characterized by atomic force microscopy (AFM), dynamic mechanical analysis (DMA) and tensile and electrical measurements. The results demonstrated that the SME was dependent on the Cu-CNT content in the nanocomposites. When comparing the SMEs of the nanocomposite specimens with different Cu-CNT contents, the 2 wt % Cu-CNT dispersed system exhibited a shape recovery as high as 98% within 35 s due to its higher electrical conductivity that results from uniform Cu-CNT dispersion. However, the nanocomposites that contained 1 wt % and 3 wt % Cu-CNTs required 75 s and 63 s, respectively, to reach a maximum recovery level. In addition, the specimens exhibited better mechanical properties after the addition of Cu-CNTs. PMID:28793570

  13. Rapid and selective screening of melamine in bovine milk using molecularly imprinted matrix solid-phase dispersion coupled with liquid chromatography-ultraviolet detection.

    PubMed

    Yan, Hongyuan; Cheng, Xiaoling; Sun, Ning; Cai, Tianyu; Wu, Ruijun; Han, Kun

    2012-11-01

    A simple, convenient and high selective molecularly imprinted matrix solid-phase dispersion (MI-MSPD) using water-compatible cyromazine-imprinted polymer as adsorbent was proposed for the rapid screening of melamine from bovine milk coupled with liquid chromatography-ultraviolet detection. The molecularly imprinted polymers (MIPs) synthesized by cyromazine as dummy template and reformative methanol-water system as reaction medium showed higher affinity and selectivity to melamine, and so they were applied as the specific dispersant of MSPD to extraction of melamine and simultaneously eliminate the effect of template leakage on quantitative analysis. Under the optimized conditions, good linearity was obtained in a range of 0.24-60.0μgg(-1) with the correlation coefficient of 0.9994. The recoveries of melamine at three spiked levels were ranged from 86.0 to 96.2% with the relative standard deviation (RSD)≤4.0%. This proposed MI-MSPD method combined the advantages of MSPD and MIPs, and could be used as an alternative tool for analyzing the residues of melamine in complex milk samples. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. A Paper-Based Analytical Device Based on Combination of Thin Film Microextraction and Reflection Scanometry for Sensitive Colorimetric Determination of Ni(II) in Aqueous Matrix.

    PubMed

    Allafchian, Ali Reza; Farajmand, Bahman; Koupaei, Amin Javaheri

    2018-04-01

    In this research, the thin film microextraction method was applied for the extraction of Ni(II) ion from aqueous matrixes. Chemically modified cellulosic filter paper with phosphorus was used as a thin film extractor. After extraction, the thin film was treated with a solution of dimethylglyoxime. The colored film was captured by flatbed scanner and the absorbance of the images was extracted by some suitable software. Under the optimum conditions and at the pH 7.0, with the sample volume of 100 mL, the stirring rate of 800 rpm, and the extraction time of 50 min, the calibration curve was obtained in the range of 0.05-5 mg/L Ni(II) (R 2  = 0.989). Limit and relative standard deviation were achieved to be 18 µg/L and less than 6.7%, respectively. Relative recoveries were obtained in the range of 87%-105%. Finally, the proposed method was found to be simple and cost-effective, with adequate analytical performance for the rapid detection of Ni(II) in river and wastewater samples.

  15. A rapid liquid chromatography tandem mass spectrometry-based method for measuring propranolol on dried blood spots.

    PubMed

    Della Bona, Maria Luisa; Malvagia, Sabrina; Villanelli, Fabio; Giocaliere, Elisa; Ombrone, Daniela; Funghini, Silvia; Filippi, Luca; Cavallaro, Giacomo; Bagnoli, Paola; Guerrini, Renzo; la Marca, Giancarlo

    2013-05-05

    Propranolol, a non-selective beta blocker drug, is used in young infants and newborns for treating several heart diseases; its pharmacokinetics has been extensively evaluated in adult patients using extrapolation to treat pediatric population. The purpose of the present study was to develop and validate a method to measure propranolol levels in dried blood spots. The analysis was performed by using liquid chromatography/tandem mass spectrometry operating in multiple reaction monitoring mode. The calibration curve in matrix was linear in the concentration range of 2.5-200 μg/L with correlation coefficient r=0.9996. Intra-day and inter-day precisions and biases were less than 8.0% (n=10) and 11.5% (n=10) respectively. The recoveries ranged from 94 to 100% and the matrix effect did not result in a severe signal suppression. Propranolol on dried blood spot showed a good stability at three different temperatures for one month. This paper describes a micromethod for measuring propranolol levels on dried blood spot, which determines a great advantage in neonates or young infants during pharmacokinetic studies because of less invasive sampling and small blood volume required. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Quantification of iprodione in dry basil using silica gel supported titanium dioxide.

    PubMed

    Maeda, Osamu; Oikawa, Chie; Noguchi, Kentaro; Shiomi, Nobuo; Toriba, Akira; Hayakawa, Kazuichi

    2010-02-10

    Iprodione is an agricultural fungicide that is difficult to detect in foods by HPLC because it coelutes with natural compounds in the food. We previously showed that food matrix could be degraded with titanium dioxide powder (TP). Here we describe an improved method for detection of iprodione using silica gel supported titanium dioxide (SGT). To synthesize SGT, titania-sol was mixed with diethanolamine, 2-propanol, and titanium tetraisopropoxide. After titania-sol was infiltrated into the silica gel (particle diameter 4 mm), the mixture was dried and then heated. Crude basil extract containing iprodione was mixed with SGT in a quartz vial, and the vial was irradiated with a UV light to selectively decompose the matrix interfering with the iprodione determination. In HPLC chromatograms of the treated solution, the interference peak decreased 35 times faster with SGT than with TP. When SGT (11 g) was added to the extract (20 mL) of dry basil (2 g), black light irradiation for 30 min was enough to quantify iprodione. The recovery rate of iprodione was 99.1%. Thus, the photocatalytic cleanup method using SGT is effective for analyzing residual iprodione in dry basil.

  17. Determination of six pesticides in the medicinal herb Cordia salicifolia by matrix solid-phase dispersion and gas chromatography/mass spectrometry.

    PubMed

    de Carvalho, Pedro Henrique Viana; Prata, Vanessa de Menezes; Alves, Péricles Barreto; Navickiene, Sandro

    2009-01-01

    A simple and effective extraction method based on matrix solid-phase dispersion was developed for acephate, chlorpropham, pyrimicarb, bifenthrin, tetradifon, and phosalone in leaves of the medicinal plant Cordia salicifolia, whose extracts are commercialized in Brazil as diuretic, appetite suppressant, and weight loss products. The determination method was GC/MS with selected-ion monitoring. Different parameters of the method were evaluated, such as type of solid phase (C18, alumina, silica gel, and Florisil) and the amount of solid phase and eluent (dichloromethane, ethyl acetate, chloroform, and cyclohexane). The best results were obtained using 0.5 g herb sample, 0.5 g neutral alumina as the dispersant sorbent, 0.5 g C18 as the cleanup sorbent, and cyclohexane-dichloromethane (3 + 1, v/v) as the eluting solvent. The method was validated using herb samples fortified with pesticides at different concentration levels (0.3, 0.5, and 1.0 mg/kg). Average recoveries (seven replicates) ranged from 67.7 to 129.9%, with relative standard deviations between 6.3 and 26%. Detection and quantitation limits for the herb ranged from 0.10 to 0.15 and 0.15 to 0.25 mg/kg, respectively.

  18. Infrared super-resolution imaging based on compressed sensing

    NASA Astrophysics Data System (ADS)

    Sui, Xiubao; Chen, Qian; Gu, Guohua; Shen, Xuewei

    2014-03-01

    The theoretical basis of traditional infrared super-resolution imaging method is Nyquist sampling theorem. The reconstruction premise is that the relative positions of the infrared objects in the low-resolution image sequences should keep fixed and the image restoration means is the inverse operation of ill-posed issues without fixed rules. The super-resolution reconstruction ability of the infrared image, algorithm's application area and stability of reconstruction algorithm are limited. To this end, we proposed super-resolution reconstruction method based on compressed sensing in this paper. In the method, we selected Toeplitz matrix as the measurement matrix and realized it by phase mask method. We researched complementary matching pursuit algorithm and selected it as the recovery algorithm. In order to adapt to the moving target and decrease imaging time, we take use of area infrared focal plane array to acquire multiple measurements at one time. Theoretically, the method breaks though Nyquist sampling theorem and can greatly improve the spatial resolution of the infrared image. The last image contrast and experiment data indicate that our method is effective in improving resolution of infrared images and is superior than some traditional super-resolution imaging method. The compressed sensing super-resolution method is expected to have a wide application prospect.

  19. Rapid enzymatic hydrolysis using a novel recombinant β-glucuronidase in benzodiazepine urinalysis.

    PubMed

    Morris, Ayodele A; Chester, Scot A; Strickland, Erin C; McIntire, Gregory L

    2014-10-01

    Only trace amounts of parent benzodiazepines are present in urine following extensive metabolism and conjugation. Thus, hydrolysis of glucuronides is necessary for improved detection. Enzyme hydrolysis is preferred to retain identification specificity, but can be costly and time-consuming. The assessment of a novel recombinant β-glucuronidase for rapid hydrolysis in benzodiazepine urinalysis is presented. Glucuronide controls for oxazepam, lorazepam and temazepam were treated with IMCSzyme™ recombinant β-glucuronidase. Hydrolysis efficiency was assessed at 55°C and at room temperature (RT) using the recommended optimum pH. Hydrolysis efficiency for four other benzodiazepines was evaluated solely with positive patient samples. Maximum hydrolysis of glucuronide controls at 5 min at RT (mean analyte recovery ≥ 94% for oxazepam and lorazepam and ≥ 80% for temazepam) was observed. This was considerably faster than the optimized 30 min incubation time for the abalone β-glucuronidase at 65°C. Mean analyte recovery increased at longer incubation times at 55°C for temazepam only. Total analyte in patient samples compared well to targets from abalone hydrolysis after recombinant β-glucuronidase hydrolysis at RT with no incubation. Some matrix effect, differential reactivity, conjugation variability and transformation impacting total analyte recovery were indicated. The unique potential of the IMCSzyme™ recombinant β-glucuronidase was demonstrated with fast benzodiazepine hydrolysis at RT leading to decreased processing time without the need for heat activation. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. Development and validation of a multiresidue method for the simultaneous determination of organophosphorus insecticides and their toxic metabolites in sugarcane juice and refined sugar by gas chromatography with flame photometric detection.

    PubMed

    Ramasubramanian, Thirumalaiandi; Paramasivam, Mariappan

    2016-06-01

    A multiresidue method has been developed and validated for the simultaneous determination of organophosphorus insecticides and their toxic metabolites in sugarcane juice and refined sugar by gas chromatography with flame photometric detection. Limits of quantification of the method varied between 0.007 and 0.01 μg/g. Ethyl acetate based extraction followed by dispersive solid-phase extraction cleanup with primary secondary amine yielded internationally acceptable recoveries of acephate, chlorpyrifos, dichlorvos, monocrotophos, malathion, malaoxon, phorate, phorate-sulfoxide, phorate-oxon, phorate-sulfone, and quinalphos from selected matrices. The recoveries of target analytes from cane juice were 75.55 ± 0.5-102.57 ± 4.2, 77.45 ± 4.7-103.33 ± 3.3, and 80.55 ± 6.6-105.82 ± 9.8% at 0.01, 0.02, and 0.1 μg/g levels of fortification, respectively. The recoveries from cane sugar were 73.24 ± 3.5-104.47 ± 1.9, 75.23 ± 1.5-116.10 ± 3.7, and 70.75 ± 5.7-110.15 ± 2.7%, respectively at 0.01, 0.02, and 0.1 μg/g levels of fortification. Matrix effect and measurement uncertainty were within the permissible limit (less than 20%) as prescribed for pesticide residue analysis. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Top