Sample records for rectal temperature measurement

  1. Comparison of rectal, tympanic membrane and axillary temperature measurement methods in dogs.

    PubMed

    Lamb, V; McBrearty, A R

    2013-11-30

    The aim of this study was to compare axillary and tympanic membrane (TM) temperature measurements to rectal temperature in a large group of clinical canine patients. We also sought to ascertain whether certain factors affected the differences between the measurements and to compare the ease of measurement. Axillary temperatures were easy to obtain but tended to be lower than rectal readings (median difference 0.6°C). In 54.7 per cent of dogs there was a difference of >0.5°C between the two readings. Weight, coat length, body condition score and breed size were significantly associated with the difference between the rectal and axillary temperature. TM temperatures were more similar to rectal temperatures (median difference 0°C) but in 25 per cent of dogs, there was a difference of >0.5°C between rectal and TM readings. TM measurements were less well tolerated than axillary measurements. None of the factors assessed were associated with the difference between the rectal and TM temperature. As a difference of >0.5°C has previously been described as unacceptable for different methods of temperature measurement, neither axillary nor TM temperatures are interchangeable with rectal temperatures for the measurement of body temperature.

  2. Measurement of body temperature in normothermic and febrile rats: Limitations of using rectal thermometry.

    PubMed

    Dangarembizi, Rachael; Erlwanger, Kennedy H; Mitchell, Duncan; Hetem, Robyn S; Madziva, Michael T; Harden, Lois M

    2017-10-01

    Stress-induced hyperthermia following rectal thermometry is reported in normothermic rats, but appears to be muted or even absent in febrile rats. We therefore investigated whether the use of rectal thermometry affects the accuracy of temperature responses recorded in normothermic and febrile rats. Using intra-abdominally implanted temperature-sensitive radiotelemeters we measured the temperature response to rectal temperature measurement in male Sprague Dawley rats (~200g) injected subcutaneously with Brewer's yeast (20ml/kg of a 20% Brewer's yeast solution=4000mg/kg) or saline (20ml/kg of 0.9% saline). Rats had been pre-exposed to, or were naive to rectal temperature measurement before the injection. The first rectal temperature measurement was taken in the plateau phase of the fever (18h after injection) and at hourly intervals thereafter. In normothermic rats, rectal temperature measurement was associated with an increase in abdominal temperature (0.66±0.27°C) that had a rapid onset (5-10min), peaked at 15-20min and lasted for 35-50min. The hyperthermic response to rectal temperature measurement was absent in febrile rats. Exposure to rectal temperature measurement on two previous occasions did not reduce the hyperthermia. There was a significant positive linear association between temperatures recorded using the two methods, but the agreement interval identified that rectal temperature measured with a thermocouple probe could either be 0.7°C greater or 0.5°C lower than abdominal temperature measured with radiotelemeter. Thus, due to stress-induced hyperthermia, rectal thermometry does not ensure accurate recording of body temperature in short-spaced, intermittent intervals in normothermic and febrile rats. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Temperature measurement in the adult emergency department: oral, tympanic membrane and temporal artery temperatures versus rectal temperature.

    PubMed

    Bijur, Polly E; Shah, Purvi D; Esses, David

    2016-12-01

    The objective was to compare agreement between three non-invasive measures of temperature and rectal temperatures and to estimate the sensitivity and specificity of these measures to detect a rectal temperature of 38°C or higher. We conducted a study of the diagnostic accuracy of oral, tympanic membrane (TM) and temporal artery (TA) thermometry to measure fever in an urban emergency department (ED). Data were collected from adult patients who received rectal temperature measurement. Bland-Altman analysis was performed; sensitivity, specificity and 95% CIs were calculated. 987 patients were enrolled. 36% of the TM and TA readings differed by 0.5°C or more from rectal temperatures, 50% of oral temperatures. TM measures were most precise-the SD of the difference from rectal was 0.4°C TM, and 0.6°C for oral and TA (p<0.001). The sensitivities of a 38°C cutpoint on oral, TM and TA measures to detect a rectal temperature of 38°C or higher were: 37.0%, 68.3% and 71.1%, respectively (oral vs TM and TA p<0.001). The corresponding specificities were 99.4%, 98.2% and 92.3% (oral, TM and TA) with oral specificity significantly higher than the other two methods (p<0.01). TM and TA cutpoints of 37.5°C provided greater than 90% sensitivity to detect fever with specificity of 90% and 72%, respectively. None of the non-invasive methods met benchmarks for diagnostic accuracy using the criterion of 38°C to detect rectal temperature of 38°C. A TM cutpoint of 37.5°C provides maximum diagnostic accuracy of the three non-invasive measures. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  4. Comparison of auricular and rectal temperature measurement in normothermic, hypothermic, and hyperthermic dogs.

    PubMed

    Konietschke, U; Kruse, B D; Müller, R; Stockhaus, C; Hartmann, K; Wehner, A

    2014-01-01

    Measurement of rectal temperature is the most common method and considered gold standard for obtaining body temperature in dogs. So far, no study has been performed comparing agreement between rectal and auricular measurements in a large case series. The purpose of the study was to assess agreement between rectal and auricular temperature measurement in normothermic, hypothermic, and hyperthermic dogs with consideration of different environmental conditions and ear conformations. Reference values for both methods were established using 62 healthy dogs. Three hundred dogs with various diseases (220 normothermic, 32 hypothermic, 48 hyperthermic) were enrolled in this prospective study. Rectal temperature was compared to auricular temperature and differences in agreement with regard to environmental temperature, relative humidity, and different ear conformations (pendulous versus prick ears) were evaluated using Pearson's correlation coefficient and Bland-Altman analysis. Correlation between rec- tal and auricular temperature was significant (r: 0.892; p  <  0.01). However, Bland-Altman plots showed an inacceptable variation of values (bias: 0.300 °C; limits of agreement: -0.606 to 1.206 °C). This variation was above a maximal clinical tolerance of 0.3 °C, which was established by experts' opinion (n = 16). Relative humidity had a significant influence (p   =   0.001), whereas environmental temperature did not. Variation between the two methods of measuring body temperature was clinically unacceptable. Although measurement of auricular temperature is fast, simple, and well tolerated, this method provides a clinically unacceptable difference to the rectal measurement.

  5. Axillary, Oral and Rectal Routes of Temperature Measurement During Treatment of Acute Kawasaki Disease.

    PubMed

    Kanegaye, John T; Jones, Jefferson M; Burns, Jane C; Jain, Sonia; Sun, Xiaoying; Jimenez-Fernandez, Susan; Berry, Erika; Pancheri, Joan M; Jaggi, Preeti; Ramilo, Octavio; Tremoulet, Adriana H

    2016-01-01

    Important therapeutic decisions are made based on the presence or absence of fever in patients with Kawasaki disease (KD), yet no standard method or threshold exists for temperature measurement during the diagnosis and treatment of these patients. We sought to compare surface and internal (rectal or oral) routes of temperature measurement for the detection of fever as a marker of treatment resistance. From a randomized, placebo-controlled trial of infliximab as an adjunct to primary intravenous immunoglobulin treatment for acute KD, we collected concurrent (within 5 minutes) axillary and internal temperature measurements and performed receiver-operating characteristic and Bland-Altman analyses. We also determined the ability of surface temperatures to detect treatment resistance defined by internal temperature measurements. Among 452 oral-axillary and 439 rectal-axillary pairs from 159 patients, mean axillary temperatures were 0.25 and 0.43 °C lower than oral and rectal temperatures and had high receiver-operating characteristic areas under curves. However, axillary temperatures ≥ 38.0 °C had limited sensitivity to detect fever defined by internal temperatures. Axillary thresholds of 37.5 and 37.2 °C provided maximal sensitivity and specificity to detect oral and rectal temperatures ≥ 38.0 °C, respectively. Axillary temperatures are an insensitive metric for fevers defining treatment resistance. Clinical trials should adopt temperature measurement by the oral or rectal routes for adjudication of treatment resistance in KD.

  6. Comparison between core temperatures measured telemetrically using the CorTemp® ingestible temperature sensor and rectal temperature in healthy Labrador retrievers

    PubMed Central

    Osinchuk, Stephanie; Taylor, Susan M.; Shmon, Cindy L.; Pharr, John; Campbell, John

    2014-01-01

    This study evaluated the CorTemp® ingestible telemetric core body temperature sensor in dogs, to establish the relationship between rectal temperature and telemetrically measured core body temperature at rest and during exercise, and to examine the effect of sensor location in the gastrointestinal (GI) tract on measured core temperature. CorTemp® sensors were administered orally to fasted Labrador retriever dogs and radiographs were taken to document sensor location. Core and rectal temperatures were monitored throughout the day in 6 resting dogs and during a 10-minute strenuous retrieving exercise in 6 dogs. Time required for the sensor to leave the stomach (120 to 610 min) was variable. Measured core temperature was consistently higher than rectal temperature across all GI locations but temperature differences based on GI location were not significant (P = 0.5218). Resting dogs had a core temperature that was on average 0.4°C above their rectal temperature with 95% limits of agreement (LoA) between 1.2°C and −0.5°C. Core temperature in exercising dogs was on average 0.3°C higher than their concurrent rectal temperature, with LoA of +1.6°C and −1.1°C. PMID:25320380

  7. Comparison between core temperatures measured telemetrically using the CorTemp® ingestible temperature sensor and rectal temperature in healthy Labrador retrievers.

    PubMed

    Osinchuk, Stephanie; Taylor, Susan M; Shmon, Cindy L; Pharr, John; Campbell, John

    2014-10-01

    This study evaluated the CorTemp(®) ingestible telemetric core body temperature sensor in dogs, to establish the relationship between rectal temperature and telemetrically measured core body temperature at rest and during exercise, and to examine the effect of sensor location in the gastrointestinal (GI) tract on measured core temperature. CorTemp(®) sensors were administered orally to fasted Labrador retriever dogs and radiographs were taken to document sensor location. Core and rectal temperatures were monitored throughout the day in 6 resting dogs and during a 10-minute strenuous retrieving exercise in 6 dogs. Time required for the sensor to leave the stomach (120 to 610 min) was variable. Measured core temperature was consistently higher than rectal temperature across all GI locations but temperature differences based on GI location were not significant (P = 0.5218). Resting dogs had a core temperature that was on average 0.4°C above their rectal temperature with 95% limits of agreement (LoA) between 1.2°C and -0.5°C. Core temperature in exercising dogs was on average 0.3°C higher than their concurrent rectal temperature, with LoA of +1.6°C and -1.1°C.

  8. Comparison between auricular and standard rectal thermometers for the measurement of body temperature in dogs

    PubMed Central

    Sousa, Marlos G.; Carareto, Roberta; Pereira-Junior, Valdo A.; Aquino, Monally C.C.

    2011-01-01

    Although the rectal mucosa remains the traditional site for measuring body temperature in dogs, an increasing number of clinicians have been using auricular temperature to estimate core body temperature. In this study, 88 mature healthy dogs had body temperatures measured with auricular and rectal thermometers. The mean temperature and confidence intervals were similar for each method, but Bland-Altman plots showed high biases and limits of agreement unacceptable for clinical purposes. The results indicate that auricular and rectal temperatures should not be interpreted interchangeably. PMID:21731094

  9. Comparison between auricular and standard rectal thermometers for the measurement of body temperature in dogs.

    PubMed

    Sousa, Marlos G; Carareto, Roberta; Pereira-Junior, Valdo A; Aquino, Monally C C

    2011-04-01

    Although the rectal mucosa remains the traditional site for measuring body temperature in dogs, an increasing number of clinicians have been using auricular temperature to estimate core body temperature. In this study, 88 mature healthy dogs had body temperatures measured with auricular and rectal thermometers. The mean temperature and confidence intervals were similar for each method, but Bland-Altman plots showed high biases and limits of agreement unacceptable for clinical purposes. The results indicate that auricular and rectal temperatures should not be interpreted interchangeably.

  10. Measurement of body temperature by use of auricular thermometers versus rectal thermometers in dogs with otitis externa.

    PubMed

    González, A Michelle; Mann, F A; Preziosi, Diane E; Meadows, Richard L; Wagner-Mann, Colette C

    2002-08-01

    To compare measurements of body temperature obtained with auricular thermometers versus rectal thermometers in dogs with otitis externa. Prospective study. 100 client-owned dogs: 50 with and 50 without clinical evidence of otitis externa. Dogs were evaluated for the presence of otitis externa on the basis of clinical signs, otoscopic examination, and cytologic evaluation of ear exudate. Auricular and rectal temperatures were obtained simultaneously in all dogs prior to and following ear examination. There was a high correlation between auricular and rectal temperatures in dogs with otitis externa both prior to and after ear manipulation. Significant differences were not detected in temperature measurements among dogs with different degrees of otitis externa. Auricular temperature readings obtained by use of an auricular thermometer in dogs with otitis externa are accurate measurements of body temperature, compared with rectal temperature measurements. Temperature measurements are reliable before and after examination of the ear canal.

  11. Agreement between auricular and rectal measurements of body temperature in healthy cats.

    PubMed

    Sousa, Marlos G; Carareto, Roberta; Pereira-Junior, Valdo A; Aquino, Monally C C

    2013-04-01

    Measurement of body temperature is a routine part of the clinical assessment of a patient. However, this procedure may be time-consuming and stressful to most animals because the standard site of temperature acquisition remains the rectal mucosa. Although an increasing number of clinicians have been using auricular temperature to estimate core body temperature, evidence is still lacking regarding agreement between these two methods in cats. In this investigation, we evaluated the agreement between temperatures measured in the rectum and ear in 29 healthy cats over a 2-week period. Temperatures were measured in the rectum (using digital and mercury-in-glass thermometers) and ear once a day for 14 consecutive days, producing 406 temperature readings for each thermometer. Mean temperature and confidence intervals were similar between methods, and Bland-Altman plots showed small biases and narrow limits of agreement acceptable for clinical purposes. The interobserver variability was also checked, which indicated a strong correlation between two near-simultaneous temperature readings. Results are consistent with auricular thermometry being a reliable alternative to rectal thermometry for assessing core body temperature in healthy cats.

  12. Pre-slaughter rectal temperature as an indicator of pork meat quality.

    PubMed

    Vermeulen, L; Van de Perre, V; Permentier, L; De Bie, S; Geers, R

    2015-07-01

    This study investigates whether rectal temperature of pigs, prior to slaughter, can give an indication of the risk of developing pork with PSE characteristics. A total of 1203 pigs were examined, measuring the rectal temperature just before stunning, of which 794 rectal temperatures were measured immediately after stunning. pH30LT (M. Longissimus thoracis) and temperature of the ham (Temp30Ham) were collected from about 530 carcasses, 30 min after sticking. The results present a significant positive linear correlation between rectal temperature just before and after slaughter, and Temp30Ham. Moreover, pH30LT is negatively correlated with rectal temperature and Temp30Ham. Finally, a linear mixed model for pH30LT was established with the rectal temperature of the pigs just before stunning and the lairage time. This model defines that measuring rectal temperature of pigs just before slaughter allows discovery of pork with PSE traits, taking into account pre-slaughter conditions. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Agreement of Axillary and Auricular Temperature with Rectal Temperature in Systemically Healthy Dogs Undergoing Surgery.

    PubMed

    Cichocki, Brandy; Dugat, Danielle; Payton, Mark

    Obtaining a patient's temperature is an important part of a patient's physical examination. As human medicine transitions to noninvasive temperature measurements, so does veterinary medicine. Historically, temperature measurement has been obtained from rectal readings; however, alternative methods, such as axillary and auricular temperatures, are increasing in popularity. The purpose of the study was to compare these alternative techniques to the gold standard of rectal temperature. Temperatures were obtained three ways for each patient: rectal, axillary, and auricular. Results indicated a positive linear relationship between rectal and axillary temperatures (bivariate correlation coefficient [r] = 0.65, P < .001) and axillary and auricular temperatures (r = 0.55, P < .001). Agreement was strongest between rectal and auricular temperatures (r = 0.80, P < .001). The average discrepancy between axillary and rectal temperature was 1.2°C [2.1°F] with the highest difference being 4.0°C [7.3°F]. The average discrepancy between auricular and rectal temperature was 0.6°C [1.2°F] with the highest difference being 2.2°C [4.1°F]. Despite auricular temperatures having stronger agreement, Bland-Altman Limits of Agreement testing revealed that it was a poor predictor of rectal temperature. Based on these results, axillary and auricular temperatures should not be substituted for rectal temperature.

  14. Comparison of axillary and rectal temperatures for healthy Beagles in a temperature- and humidity-controlled environment.

    PubMed

    Mathis, Justin C; Campbell, Vicki L

    2015-07-01

    To compare axillary and rectal temperature measurements obtained with a digital thermometer for Beagles in a temperature- and humidity-controlled environment. 26 healthy Beagles (17 sexually intact males and 9 sexually intact females). Dogs were maintained in a temperature- and humidity-controlled environment for 56 days before rectal and axillary temperatures were measured. Axillary and rectal temperatures were obtained in triplicate for each dog by use of a single commercially available manufacturer-calibrated digital thermometer. Mean rectal and axillary temperatures of Beagles maintained in a temperature- and humidity-controlled environment were significantly different, with a median ± SD difference of 1.4° ± 0.15°C (range, 0.7° to 2.1°C). Mean rectal and axillary temperatures were 38.7°C (range, 37.6° to 39.5°C) and 37.2°C (range, 36.6° to 38.3°C), respectively. Results of this study indicated that the historical reference of a 0.55°C gradient between rectal and axillary temperatures that has been clinically used for veterinary patients was inaccurate for healthy Beagles in a temperature- and humidity-controlled environment. Rectal and axillary temperatures can be measured in veterinary patients. Reliable interpretation of axillary temperatures may accommodate patient comfort and reduce patient anxiety when serial measurement of temperatures is necessary. Further clinical studies will be needed.

  15. Temperature measurement in intensive care patients: comparison of urinary bladder, oesophageal, rectal, axillary, and inguinal methods versus pulmonary artery core method.

    PubMed

    Lefrant, J-Y; Muller, L; de La Coussaye, J Emmanuel; Benbabaali, M; Lebris, C; Zeitoun, N; Mari, C; Saïssi, G; Ripart, J; Eledjam, J-J

    2003-03-01

    Comparisons of urinary bladder, oesophageal, rectal, axillary, and inguinal temperatures versus pulmonary artery temperature. Prospective cohort study. Intensive Care Unit of a University-Hospital. Forty-two intensive care patients requiring a pulmonary artery catheter (PAC). Patients requiring PAC and without oesophageal, urinary bladder, and/or rectal disease or recent surgery were included in the study. Temperature was simultaneously monitored with PAC, urinary, oesophageal, and rectal electronic thermometers and with axillary and inguinal gallium-in-glass thermometers. Comparisons used a Bland and Altman method. The pulmonary arterial temperature ranged from 33.7 degrees C to 40.2 degrees C. Urinary bladder temperature was assessed in the last 22 patients. A total of 529 temperature measurement comparisons were carried out (252 comparisons of esophageal, rectal, inguinal, axillary, and pulmonary artery temperature measurements in the first 20 patients, and 277 comparisons with overall methods in the last patients). Nine to 18 temperature measurement comparisons were carried out per patient (median = 13). The mean differences between pulmonary artery temperatures and those of the different methods studied were: oesophageal (0.11+/-0.30 degrees C), rectal (-0.07+/-0.40 degrees C), axillary (0.27+/-0.45 degrees C), inguinal (0.17+/-0.48 degrees C), urinary bladder (-0.21+/-0.20 degrees C). In critically ill patients, urinary bladder and oesophageal electronic thermometers are more reliable than the electronic rectal thermometer which is better than inguinal and axillary gallium-in-glass thermometers to measure core temperature.

  16. Comparison of rectal and axillary temperatures in dogs and cats.

    PubMed

    Goic, Joana B; Reineke, Erica L; Drobatz, Kenneth J

    2014-05-15

    To compare rectal versus axillary temperatures in dogs and cats. Prospective observational study. 94 dogs and 31 cats. Paired axillary and rectal temperatures were measured in random order with a standardized method. Animal signalment, initial complaint, blood pressure, blood lactate concentration, and variables associated with vascular perfusion and coat were evaluated for associations with axillary and rectal temperatures. Axillary temperature was positively correlated with rectal temperature (ρ = 0.75 in both species). Median axillary temperature (38.4°C [101.1°F] in dogs, and 38.4°C [101.2°F] in cats) was significantly different from median rectal temperature in dogs (38.9°C [102.0°F]) but not in cats (38.6°C [101.5°F]). Median rectal-axillary gradient (difference) was 0.4°C (0.7°F; range, -1.3° to 2.3°C [-2.4° to 4.1°F]) in dogs and 0.17°C (0.3°F; range -1.1° to 1.6°C [-1.9° to 3°F]) in cats. Sensitivity and specificity for detection of hyperthermia with axillary temperature were 57% and 100%, respectively, in dogs and 33% and 100%, respectively, in cats; sensitivity and specificity for detection of hypothermia were 86% and 87%, respectively, in dogs and 80% and 96%, respectively, in cats. Body weight (ρ = 0.514) and body condition score (ρ = 0.431) were correlated with rectal-axillary gradient in cats. Although axillary and rectal temperatures were correlated in dogs and cats, a large gradient was present between rectal temperature and axillary temperature, suggesting that axillary temperature should not be used as a substitute for rectal temperature.

  17. Automated measurement of cattle surface temperature and its correlation with rectal temperature

    PubMed Central

    Ren, Kang; Chen, XiaoLi; Lu, YongQiang; Wang, Dong

    2017-01-01

    The body temperature of cattle varies regularly with both the reproductive cycle and disease status. Establishing an automatic method for monitoring body temperature may facilitate better management of reproduction and disease control in cattle. Here, we developed an Automatic Measurement System for Cattle’s Surface Temperature (AMSCST) to measure the temperature of metatarsus by attaching a special shell designed to fit the anatomy of cattle’s hind leg. Using AMSCST, the surface temperature (ST) on the metatarsus of the hind leg was successively measured during 24 hours a day with an interval of one hour in three tested seasons. Based on ST and rectal temperature (RT) detected by AMSCST and mercury thermometer, respectively, a linear mixed model was established, regarding both the time point and seasonal factors as the fixed effects. Unary linear correlation and Bland-Altman analysis results indicated that the temperatures measured by AMSCST were closely correlated to those measured by mercury thermometer (R2 = 0.998), suggesting that the AMSCST is an accurate and reliable way to detect cattle’s body temperature. Statistical analysis showed that the differences of STs among the three seasons, or among the different time points were significant (P<0.05), and the differences of RTs among the different time points were similarly significant (P<0.05). The prediction accuracy of the mixed model was verified by 10-fold cross validation. The average difference between measured RT and predicted RT was about 0.10 ± 0.10°C with the association coefficient of 0.644, indicating the feasibility of this model in measuring cattle body temperature. Therefore, an automated technology for accurately measuring cattle body temperature was accomplished by inventing an optimal device and establishing the AMSCST system. PMID:28426682

  18. Core Temperature Measurement During Submaximal Exercise: Esophageal, Rectal, and Intestinal Temperatures

    NASA Technical Reports Server (NTRS)

    Lee, Stuart M. C.; Williams, W. Jon; Schneider, Suzanne M.

    2000-01-01

    The purpose of this study was to determine if intestinal temperature (Tin) might be in acceptable alternative to esophageal (Tes) and rectal temperature (Trec) to assess thermoregulation during supine exercise. We hypothesized that Tin would have values similar to Tes and a response time similar to Trec, but the rate of temperature change across time would not be different between measurement sites. Seven subjects completed a continuous supine protocol of 20 min of rest, 20 min of cycle exercise at 40% peak oxygen consumption (VO2pk), 20 min of cycle exercise at 65% V02pk, and 20 min of recovery. Tes, Trec, and Tin were recorded each min throughout the test. Temperatures were not different after 20 min of rest, but Trec was less than the Tes and Tin at the end of the 40% and 65% VO2pk stages. After 20 min of recovery, Tes was less than either Trec or Tin, which were not different from each other. Time to threshold for increased temperature from rest was greater for Trec than Tes but not different from Tin. Time to reach peak temperature was greater for Tin and Trec than Tes. Similarly, time to a decrease in temperature after exercise was greater for Trec than Tes, but not different from Tin. The rate of temperature change from threshold to the end of the 40% VO2pk stage was not different between measurement sites. However, the rate of change during recovery was more negative for Tes than Tin and Trec, which were different from each other. Measurement of Tin may he an acceptable alternative to Tes and Trec with an understanding of its limitations.

  19. Technical note: Development of a self-contained, indwelling rectal temperature probe for cattle research.

    PubMed

    Reuter, R R; Carroll, J A; Hulbert, L E; Dailey, J W; Galyean, M L

    2010-10-01

    A device was developed to monitor rectal temperature automatically in cattle for application in research settings. Compared with manual measurement of rectal temperature, this device decreases labor and time requirements and allows data collection without the influence of animal handling or restraint. The device consists of a custom-fabricated aluminum tail harness that supports an indwelling rectal temperature data logger. Materials cost approximately US $300 per unit, and units are completely reusable. Use of this device would increase the conditions under which accurate rectal temperature measurements can be obtained in experiments with cattle.

  20. Validity of Core Temperature Measurements at 3 Rectal Depths During Rest, Exercise, Cold-Water Immersion, and Recovery

    PubMed Central

    Miller, Kevin C.; Hughes, Lexie E.; Long, Blaine C.; Adams, William M.; Casa, Douglas J.

    2017-01-01

    Context: No evidence-based recommendation exists regarding how far clinicians should insert a rectal thermistor to obtain the most valid estimate of core temperature. Knowing the validity of temperatures at different rectal depths has implications for exertional heat-stroke (EHS) management. Objective: To determine whether rectal temperature (Trec) taken at 4 cm, 10 cm, or 15 cm from the anal sphincter provides the most valid estimate of core temperature (as determined by esophageal temperature [Teso]) during similar stressors an athlete with EHS may experience. Design: Cross-sectional study. Setting: Laboratory. Patients or Other Participants: Seventeen individuals (14 men, 3 women: age = 23 ± 2 years, mass = 79.7 ± 12.4 kg, height = 177.8 ± 9.8 cm, body fat = 9.4% ± 4.1%, body surface area = 1.97 ± 0.19 m2). Intervention(s): Rectal temperatures taken at 4 cm, 10 cm, and 15 cm from the anal sphincter were compared with Teso during a 10-minute rest period; exercise until the participant's Teso reached 39.5°C; cold-water immersion (∼10°C) until all temperatures were ≤38°C; and a 30-minute postimmersion recovery period. The Teso and Trec were compared every minute during rest and recovery. Because exercise and cooling times varied, we compared temperatures at 10% intervals of total exercise and cooling durations for these periods. Main Outcome Measure(s): The Teso and Trec were used to calculate bias (ie, the difference in temperatures between sites). Results: Rectal depth affected bias (F2,24 = 6.8, P = .008). Bias at 4 cm (0.85°C ± 0.78°C) was higher than at 15 cm (0.65°C ± 0.68°C, P < .05) but not higher than at 10 cm (0.75°C ± 0.76°C, P > .05). Bias varied over time (F2,34 = 79.5, P < .001). Bias during rest (0.42°C ± 0.27°C), exercise (0.23°C ± 0.53°C), and recovery (0.65°C ± 0.35°C) was less than during cooling (1.72°C ± 0.65°C, P < .05). Bias during exercise was less than during postimmersion recovery (0.65°C ± 0.35°C, P

  1. Rectal temperatures of immobilized, snare-trapped black bears in Great Dismal Swamp.

    PubMed

    Hellgren, E C; Vaughan, M R

    1989-07-01

    Rectal temperature was determined for 84 black bears (Ursus americanus) during 99 handlings in Great Dismal Swamp, Virginia and North Carolina (USA). All bears had been trapped with cable snares and immobilized with a 2:1 ketamine hydrochloridexylazine hydrochloride mixture. Temperatures were significantly greater in males and varied significantly by season. Immobilized bears began panting at rectal temperatures greater than 42.0 C. One death occurred at 43.0 C. We recommended cooling measures on black bears at rectal temperatures of greater than or equal to 40.0 C.

  2. Comparison of tympanic and rectal temperature in febrile patients.

    PubMed

    Sehgal, Arvind; Dubey, N K; Jyothi, M C; Jain, Shilpa

    2002-04-01

    To compare tympanic membrane temperature and rectal temperature in febrile pediatric patients. Sixty febrile children were enrolled as continuous enrollment at initial triage. Two readings of ear temperature were taken in each child with Thermoscan infrared thermometer. Rectal temperature was recorded by a digital electronic thermometer. Comparison of both the techniques was done and co-relation co-efficients calculated. Parental preference for both techniques was assessed. It was observed that mean ear temperature was 38.9+/-0.90 C and that for rectal temperature was 38.8+/-0.80 degrees C. The correlation coefficient between the two was 0.994 (p < 0.01). Coefficients for both sites were comparable over a wide age range. The difference between readings taken from two ears was not significant. Temperature ranges over which readings were recorded were quite wide for both techniques. Parental preference for tympanic thermometry over rectal thermometry was noticed. Tympanic thermometry utilizes pyro-electric sensors, to detect infra-red rays emitted from the surface of tympanic membrane. Ear temperatures correlates well with rectal temperatures which have long been considered as "core" temperatures. Parents prefer the technique of ear thermometry which is quick (2 sec), safe and non-invasive and patient resistance for this is also less. A non-invasive, non-mucous device which is accurate over a wide range of temperature could be very useful.

  3. Tympanic, Infrared Skin, and Temporal Artery Scan Thermometers Compared with Rectal Measurement in Children: A Real-Life Assessment

    PubMed Central

    Allegaert, Karel; Casteels, Kristina; van Gorp, Ilse; Bogaert, Guy

    2014-01-01

    Introduction Body temperature measurement in children is of clinical relevance. Although rectal measurement is the gold standard, less invasive tools have become available. We aimed to describe the accuracy of tympanic, infrared skin, or temporal artery scan thermometers compared with rectal measurement to reflect core temperature. Methods Rectal (Filac 3000; Covidien, Mechelen, Belgium), tympanic (AccuSystem Genius2 Typmanic Infrared Ear Thermometer, Covidien, Mechelen, Belgium), temporal artery scan (Exergen, Exergen Corp, Watertown, Massachusetts), and infrared (ThermoFlash Contactless Medical Electronic Thermometer, Visiomedlab, Paris, France) body temperature measurements were randomly performed and readings were collected once. Temperature readings were described as median and range, and observations were compared with rectal temperature readings (using Wilcoxon, Bland-Altman, sensitivity, and specificity tests). The child’s comfort was assessed by the child, parent, and nurse (using Likert scales) and ease of use was assessed by nurses (using visual analog scale). Results Based on observations in 294 (median age = 3.2 years, range = 0.02–17 years) children, the mean difference was 0.49°C (tympanic scan; P < 0.0001), 0.34°C (infrared skin scan; P < 0.0001), and 0°C (temporal artery scan; P = 0.9288), respectively, when compared with rectal temperature readings. Based on visual inspection of Bland-Altman plots, all tools overestimated the temperature at lower body temperature and underestimated the temperature at higher body temperature, resulting in a sensitivity of 22% to 41% and a specificity of 98% to 100% for rectal temperatures above 38°C. The Likert scale scores and the visual analog scale scores for rectal measurement were only slightly higher when compared with the other methods. Conclusions All noninvasive techniques underperformed compared with rectal measurement. The temporal artery scan deviations were smallest, but all noninvasive

  4. Comparison of rectal and infrared thermometry for obtaining body temperature in cynomolgus macaques (Macaca fascicularis).

    PubMed

    Sikoski, P; Banks, M L; Gould, R; Young, R W; Wallace, J M; Nader, M A

    2007-12-01

    It would be clinically advantageous to develop a method of body temperature evaluation in cynomolgus macaques (Macaca fascicularis) that did not require sedation, restraint, surgical manipulation, or expensive equipment. Body temperatures of 51 cynomolgus macaques were taken with rectal thermometry and non-contact infrared thermometry (NIFT) on the shoulder, face, abdomen, and axillary region. Body temperature measurements from NIFT were statistically different (P < 0.0001) from rectal thermometry. In addition, there was greater between- and within-subject variability in values using NIFT. There was no correlation between any sites of the NIFT and rectal thermometry. It was concluded that NIFT was not a valid alternative to rectal thermometry in cynomolgus macaques.

  5. Body temperature measurements in pigs during general anaesthesia.

    PubMed

    Musk, G C; Costa, R S; Tuke, J

    2016-04-01

    The aim was to compare rectal, pharyngeal and oesophageal temperature measurements in anaesthetized pigs. Data were compared using the Bland-Altman method, and correlation coefficients and error measures were calculated. Sixty-six sets of data were collected from 16 pigs weighing 16.2 ± 4.2 kg. The bias (and 95% limit of agreement) for rectal and pharyngeal compared with oesophageal temperature were 0.69 (-1.18 to 2.57) ℃ and 0.22 (-0.84 to 1.28) ℃, respectively. The correlation coefficients for rectal and pharyngeal compared with oesophageal temperature were 0.47 and 0.87, respectively. The absolute error for rectal and pharyngeal compared with oesophageal temperature was 0.7 ± 0.9℃ and 0.2 ± 0.5℃, respectively. Pharyngeal temperature measurement may be more suitable than rectal temperature measurement for estimation of oesophageal temperature during general anaesthesia of pigs. © The Author(s) 2015.

  6. Validity of Core Temperature Measurements at 3 Rectal Depths During Rest, Exercise, Cold-Water Immersion, and Recovery.

    PubMed

    Miller, Kevin C; Hughes, Lexie E; Long, Blaine C; Adams, William M; Casa, Douglas J

    2017-04-01

      No evidence-based recommendation exists regarding how far clinicians should insert a rectal thermistor to obtain the most valid estimate of core temperature. Knowing the validity of temperatures at different rectal depths has implications for exertional heat-stroke (EHS) management.   To determine whether rectal temperature (T rec ) taken at 4 cm, 10 cm, or 15 cm from the anal sphincter provides the most valid estimate of core temperature (as determined by esophageal temperature [T eso ]) during similar stressors an athlete with EHS may experience.   Cross-sectional study.   Laboratory.   Seventeen individuals (14 men, 3 women: age = 23 ± 2 years, mass = 79.7 ± 12.4 kg, height = 177.8 ± 9.8 cm, body fat = 9.4% ± 4.1%, body surface area = 1.97 ± 0.19 m 2 ).   Rectal temperatures taken at 4 cm, 10 cm, and 15 cm from the anal sphincter were compared with T eso during a 10-minute rest period; exercise until the participant's T eso reached 39.5°C; cold-water immersion (∼10°C) until all temperatures were ≤38°C; and a 30-minute postimmersion recovery period. The T eso and T rec were compared every minute during rest and recovery. Because exercise and cooling times varied, we compared temperatures at 10% intervals of total exercise and cooling durations for these periods.   The T eso and T rec were used to calculate bias (ie, the difference in temperatures between sites).   Rectal depth affected bias (F 2,24 = 6.8, P = .008). Bias at 4 cm (0.85°C ± 0.78°C) was higher than at 15 cm (0.65°C ± 0.68°C, P < .05) but not higher than at 10 cm (0.75°C ± 0.76°C, P > .05). Bias varied over time (F 2,34 = 79.5, P < .001). Bias during rest (0.42°C ± 0.27°C), exercise (0.23°C ± 0.53°C), and recovery (0.65°C ± 0.35°C) was less than during cooling (1.72°C ± 0.65°C, P < .05). Bias during exercise was less than during postimmersion recovery (0.65°C ± 0.35°C, P < .05).   When EHS is suspected, clinicians should insert the flexible

  7. Ovarian cycle approach by rectal temperature and fecal progesterone in a female killer whale, Orcinus orca.

    PubMed

    Kusuda, Satoshi; Kakizoe, Yuka; Kanda, Koji; Sengoku, Tomoko; Fukumoto, Yohei; Adachi, Itsuki; Watanabe, Yoko; Doi, Osamu

    2011-01-01

    This study aimed to validate the measurements of body temperature and fecal progesterone concentrations as minimally invasive techniques for assessing ovarian cycle in a single sexually mature female killer whale. Rectal temperature data, fecal and blood samples were collected in the dorsal position using routine husbandry training on a voluntary basis. The correlations between rectal temperature and plasma progesterone concentration and between fecal and plasma progesterone concentrations were investigated. Fecal progesterone metabolites were identified by a combination of high-performance liquid chromatography and enzyme immunoassay. Plasma progesterone concentrations (range: 0.2-18.6 ng/ml) and rectal temperature (range: 35.3-35.9°C) changed cyclically, and cycle lengths were an average (±SD) of 44.9±4.0 days (nine cycles) and 44.6±5.9 days (nine cycles), respectively. Rectal temperature positively correlated with the plasma progesterone concentrations (r=0.641, P<0.01). There was a visual trend for fecal progesterone profiles to be similar to circulating plasma progesterone profiles. Fecal immunoreactive progestagen analysis resulted in a marked immunoreactive peak of progesterone. The data from the single killer whale indicate that the measurement of rectal temperature is suitable for minimally invasive assessment of the estrous cycle and monitoring the fecal progesterone concentration is useful to assess ovarian luteal activity. © 2010 Wiley-Liss, Inc.

  8. Hypothalamic, rectal, and muscle temperatures in exercising dogs - Effect of cooling

    NASA Technical Reports Server (NTRS)

    Kruk, B.; Kaciuba-Uscilko, H.; Nazar, K.; Greenleaf, J. E.; Kozlowski, S.

    1985-01-01

    An experimental investigation of the mechanisms of performance prolongation during exercise is presented. Measurements were obtained of the rectal, muscle, and hypothalamic temperature of dogs during treadmill exercise at an ambient temperature of 22 + or - 1 C, with and without cooling by use of ice packs. In comparison with exercise without cooling, exercise with cooling was found to: (1) increase exercise duration from 90 + or - 14 to 145 + or - 15 min; (2) attenuate increases in hypothalamic, rectal and muscle temperature; (3) decrease respiratory and heart rates; and (4) lower blood lactic acid content. It is shown that although significant differences were found between the brain, core, and muscle temperatures during exercise with and without cooling, an inverse relation was observed between muscle temperature and the total duration of exercise. It is suggested that sustained muscle hyperthermia may have contributed to the limitation of working ability in exercise with and without cooling.

  9. Application of vaginal temperature measurement in bitches.

    PubMed

    Maeder, B; Arlt, S; Burfeind, O; Heuwieser, W

    2012-12-01

    Finding innovative, non-invasive methods for continuously measuring body temperature minimizing human interference is important for accurate data collection. The objective of this study was to assess feasibility and accuracy of continuous body temperature measurements with loggers placed in the vaginal cavity of bitches. First, an in vitro experiment was performed to compare values obtained by temperature loggers (n = 26) to a calibrated liquid-in-glass thermometer. The mean differences between the two methods were low. Next, an in vivo experiment was performed using five healthy bitches, and values obtained by the vaginal loggers were compared to measurements collected rectally with digital thermometers. The results show that rectal and vaginal temperatures were correlated. The mean differences between rectal and vaginal temperatures were negligible. We conclude that the utilized temperature loggers provide accurate and reliable data. © 2012 Blackwell Verlag GmbH.

  10. Relationship among eye and muzzle temperatures measured using digital infrared thermal imaging and vaginal and rectal temperatures in hair sheep and cattle.

    PubMed

    George, W D; Godfrey, R W; Ketring, R C; Vinson, M C; Willard, S T

    2014-11-01

    Digital infrared thermal imaging (DITI) using a thermal camera has potential to be a useful tool for the production animal industry. Thermography has been used in both humans and a wide range of animal species to measure body temperature as a method to detect injury or inflammation. The objective of these experiments was to compare the temperature of the eye (EYE) or muzzle (MUZ) measured using DITI to vaginal (VT) and rectal temperature (RT) as measures of core body temperature in hair sheep and beef cattle. In Exp.1 EYE, VT and RT were measured in lactating, multiparous hair sheep ewes (St. Croix White, n = 10, and Dorper × St. Croix White, n = 10) in a non-febrile state 5 times over a 48-h period. Data loggers were used to measure VT and a digital veterinary thermometer was used to measure RT. There was a high correlation (P < 0.001) between VT and RT (r = 0.95), EYE and RT (r = 0.76) and EYE and VT (r = 0.77). In Exp. 2 EYE, MUZ, VT and RT were measured in multiparous, lactating ewes (St. Croix White, n = 2, and Barbados Blackbelly, n = 12) at -12, -1, 0, 1, 2, 3, 4, 6, 12, 24, 36, and 48 h after being administered lipopolysaccharide (LPS; n = 7; 0.2 µg/kg BW, i.v.) or saline (n = 7; 0.5 mL, i.v.). Data loggers were used to measure VT and a digital veterinary thermometer was used to measure RT. When data were combined across treatments (LPS and saline) there was a high correlation (P < 0.001) between VT and RT (r = 0.96), EYE and RT (r = 0.82), MUZ and RT (r = 0.72), and EYE and VT (r = 0.93). In Exp. 3 EYE, MUZ, VT and RT were measured in multiparous, non-lactating, pregnant Senepol cattle (n = 44) between 0900 and 1200 h on a single day. A digital veterinary thermometer was used to measure both VT and RT. There was a high correlation (P < 0.001) between VT and RT (r = 0.78), a moderate correlation (P < 0.001) between VT and EYE (r = 0.52), RT and EYE (r = 0.58) and EYE and MUZ (r = 0.48). There was no correlation (P > 0.10) between RT or VT and MUZ. The

  11. Effects of a whole-body spandex garment on rectal temperature and oxygen consumption in healthy dogs.

    PubMed

    Reimer, S Brent; Schulz, Kurt S; Mason, David R; Jones, James H

    2004-01-01

    To determine whether a full-body spandex garment would alter rectal temperatures of healthy dogs at rest in cool and warm environments. Prospective study. 10 healthy dogs. Each dog was evaluated at a low (20 degrees to 25 degrees C [68 degrees to 77 degrees F]) or high (30 degrees to 35 degrees C [86 degrees to 95 degrees F]) ambient temperature while wearing or not wearing a commercially available whole-body spandex garment designed for dogs. Oxygen consumption was measured by placing dogs in a flow-through indirect calorimeter for 90 to 120 minutes. Rectal temperature was measured before dogs were placed in the calorimeter and after they were removed. Rectal temperature increased significantly more at the higher ambient temperature than at the lower temperature and when dogs were not wearing the garment than when they were wearing it. The specific rate of oxygen consumption was significantly higher at the lower ambient temperature than at the higher temperature. Results suggest that wearing a snug spandex body garment does not increase the possibility that dogs will overheat while in moderate ambient temperatures. Instead, wearing such a garment may enable dogs to better maintain body temperature during moderate heat loading. These results suggest that such garments might be used for purposes such as wound or suture protection without causing dogs to overheat.

  12. [Comparison of different methods of temperature measurment in children].

    PubMed

    Pavlović, Momcilo; Radlović, Nedeljko; Leković, Zoran; Berenji, Karolina

    2008-01-01

    The consequences of failing to notice fever in children can be serious. On the other hand, false positive reading can result in unnecesery investigation or diagnostic approach. The aim of this study was to compare different ways of body temperature measurement. This prospective study was carried out on Pediatric Department of General Hospital in Subotica during 10 months (March-December 2006). In 263 children aged 1 month to 18 years of age, the body temperature was obtained from 4 measurement sites: tactile assesment, forehead and ear by electronic thermometer, rectal temperature in small children (up to 2 years of age) or axillar temperature in older children by mercury thermometer. Tympanic thermometry was considered as a standard for fever detection. The sensitivity of rectal temperature to detect fever is 46.67%, while specificity is 92.19%. The sensitivity of fever detection by electronic thermometry on the forehead is lower according to rectal thermometry - 36.08%, while specificity is 95.18%. The lowest values ofsensitivity are recorded in axillar thermometry (35.82%), specificity is 90.20%. The correlation coefficient is higher between tympanic and rectal temperature measurement (r=0.5076, p<0.0005), than between tympanic and forehead measurements (r=0.5076, p<0,0005), while the lowest was between tympanic and axillar mesurement sites (r=0.4933, p<0.0005). The results of our study and literature data show that the most accurate methods of thermometry are rectal measurement of body temperature in small children and tympanic thermometry in children over 2 years of age.

  13. Comparison of three methods of temperature measurement in hypothermic, euthermic, and hyperthermic dogs.

    PubMed

    Greer, Rebecca J; Cohn, Leah A; Dodam, John R; Wagner-Mann, Colette C; Mann, F A

    2007-06-15

    To assess the reliability and accuracy of a predictive rectal thermometer, an infrared auricular thermometer designed for veterinary use, and a subcutaneous temperature-sensing microchip for measurement of core body temperature over various temperature conditions in dogs. Prospective study. 8 purpose-bred dogs. A minimum of 7 days prior to study commencement, a subcutaneous temperature-sensing microchip was implanted in 1 of 3 locations (interscapular, lateral aspect of shoulder, or sacral region) in each dog. For comparison with temperatures measured via rectal thermometer, infrared auricular thermometer, and microchip, core body temperature was measured via a thermistor-tipped pulmonary artery (TTPA) catheter. Hypothermia was induced during anesthesia at the time of TTPA catheter placement; on 3 occasions after placement of the catheter, hyperthermia was induced via administration of a low dose of endotoxin. Near-simultaneous duplicate temperature measurements were recorded from the TTPA catheter, the rectal thermometer, auricular thermometer, and subcutaneous microchips during hypothermia, euthermia, and hyperthermia. Reliability (variability) of temperature measurement for each device and agreement between each device measurement and core body temperature were assessed. Variability between duplicate near-simultaneous temperature measurements was greatest for the auricular thermometer and least for the TTPA catheter. Measurements obtained by use of the rectal thermometer were in closest agreement with core body temperature; for all other devices, temperature readings typically underestimated core body temperature. Among the 3 methods of temperature measurement, rectal thermometry provided the most accurate estimation of core body temperature in dogs.

  14. Comparison of estimated core body temperature measured with the BioHarness and rectal temperature under several heat stress conditions.

    PubMed

    Seo, Yongsuk; DiLeo, Travis; Powell, Jeffrey B; Kim, Jung-Hyun; Roberge, Raymond J; Coca, Aitor

    2016-08-01

    Monitoring and measuring core body temperature is important to prevent or minimize physiological strain and cognitive dysfunction for workers such as first responders (e.g., firefighters) and military personnel. The purpose of this study is to compare estimated core body temperature (Tco-est), determined by heart rate (HR) data from a wearable chest strap physiology monitor, to standard rectal thermometry (Tre) under different conditions.  Tco-est and Tre measurements were obtained in thermoneutral and heat stress conditions (high temperature and relative humidity) during four different experiments including treadmill exercise, cycling exercise, passive heat stress, and treadmill exercise while wearing personal protective equipment (PPE).  Overall, the mean Tco-est did not differ significantly from Tre across the four conditions. During exercise at low-moderate work rates under heat stress conditions, Tco-est was consistently higher than Tre at all-time points. Tco-est underestimated temperature compared to Tre at rest in heat stress conditions and at a low work rate under heat stress while wearing PPE. The mean differences between the two measurements ranged from -0.1 ± 0.4 to 0.3 ± 0.4°C and Tco-est correlated well with HR (r = 0.795 - 0.849) and mean body temperature (r = 0.637 - 0.861).  These results indicate that, the comparison of Tco-est to Tre may result in over- or underestimation which could possibly lead to heat-related illness during monitoring in certain conditions. Modifications to the current algorithm should be considered to address such issues.

  15. Comparison of rectal, microchip transponder, and infrared thermometry techniques for obtaining body temperature in the laboratory rabbit (Oryctolagus cuniculus).

    PubMed

    Chen, Patty H; White, Charles E

    2006-01-01

    This study compared rabbit rectal thermometry with 4 other thermometry techniques: an implantable microchip temperature transponder, an environmental noncontact infrared thermometer, a tympanic infrared thermometer designed for use on humans, and a tympanic infrared thermometer designed for use on animals. The microchip transponder was implanted between the shoulder blades; the environmental noncontact infrared thermometer recorded results from the base of the right pinna and the left inner thigh, and the tympanic infrared thermometer temperatures were taken from the right ear. Results from each technique were compared to determine agreement between the test modality and the rectal temperature. The practicality and reliability of the modalities were reviewed also. According to this study, the implantable microchip transponder measurements agreed most closely with the rectal temperature.

  16. Heritability of rectal temperature and genetic correlations with production and reproduction traits in dairy cattle.

    PubMed

    Dikmen, S; Cole, J B; Null, D J; Hansen, P J

    2012-06-01

    Genetic selection for body temperature during heat stress might be a useful approach to reduce the magnitude of heat stress effects on production and reproduction. Objectives of the study were to estimate the genetic parameters of rectal temperature (RT) in dairy cows in freestall barns under heat stress conditions and to determine the genetic and phenotypic correlations of rectal temperature with other traits. Afternoon RT were measured in a total of 1,695 lactating Holstein cows sired by 509 bulls during the summer in North Florida. Genetic parameters were estimated with Gibbs sampling, and best linear unbiased predictions of breeding values were predicted using an animal model. The heritability of RT was estimated to be 0.17 ± 0.13. Predicted transmitting abilities for rectal temperature changed 0.0068 ± 0.0020°C/yr from (birth year) 2002 to 2008. Approximate genetic correlations between RT and 305-d milk, fat, and protein yields, productive life, and net merit were significant and positive, whereas approximate genetic correlations between RT and somatic cell count score and daughter pregnancy rate were significant and negative. Rectal temperature during heat stress has moderate heritability, but genetic correlations with economically important traits mean that selection for RT could lead to lower productivity unless methods are used to identify genes affecting RT that do not adversely affect other traits of economic importance. Copyright © 2012 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  17. Non-invasive body temperature measurement of wild chimpanzees using fecal temperature decline.

    PubMed

    Jensen, Siv Aina; Mundry, Roger; Nunn, Charles L; Boesch, Christophe; Leendertz, Fabian H

    2009-04-01

    New methods are required to increase our understanding of pathologic processes in wild mammals. We developed a noninvasive field method to estimate the body temperature of wild living chimpanzees habituated to humans, based on statistically fitting temperature decline of feces after defecation. The method was established with the use of control measures of human rectal temperature and subsequent changes in fecal temperature over time. The method was then applied to temperature data collected from wild chimpanzee feces. In humans, we found good correspondence between the temperature estimated by the method and the actual rectal temperature that was measured (maximum deviation 0.22 C). The method was successfully applied and the average estimated temperature of the chimpanzees was 37.2 C. This simple-to-use field method reliably estimates the body temperature of wild chimpanzees and probably also other large mammals.

  18. Rectal Diclofenac Versus Rectal Paracetamol: Comparison of Antipyretic Effectiveness in Children.

    PubMed

    Sharif, Mohammad Reza; Haji Rezaei, Mostafa; Aalinezhad, Marzieh; Sarami, Golbahareh; Rangraz, Masoud

    2016-01-01

    Fever is the most common complaint in pediatric medicine and its treatment is recommended in some situations. Paracetamol is the most common antipyretic drug, which has serious side effects such as toxicity along with its positive effects. Diclofenac is one of the strongest non-steroidal anti-inflammatory (NSAID) drugs, which has received little attention as an antipyretic drug. This study was designed to compare the antipyretic effectiveness of the rectal form of Paracetamol and Diclofenac. This double-blind controlled clinical trial was conducted on 80 children aged six months to six years old. One group was treated with rectal Paracetamol suppositories at 15 mg/kg dose and the other group received Diclofenac at 1 mg/kg by rectal administration (n = 40). Rectal temperature was measured before and one hour after the intervention. Temperature changes in the two groups were compared. The average rectal temperature in the Paracetamol group was 39.6 ± 1.13°C, and 39.82 ± 1.07°C in the Diclofenac group (P = 0.37). The average rectal temperature, one hour after the intervention, in the Paracetamol and the Diclofenac group was 38.39 ± 0.89°C and 38.95 ± 1.09°C, respectively (P = 0.02). Average temperature changes were 0.65 ± 0.17°C in the Paracetamol group and 1.73 ± 0.69°C in the Diclofenac group (P < 0.001). In the first one hour, Diclofenac suppository is able to control the fever more efficient than Paracetamol suppositories.

  19. Effects of 2 commercially-available 9-way killed vaccines on milk production and rectal temperature in Holstein-Friesian dairy cows.

    PubMed Central

    Scott, H M; Atkins, G; Willows, B; McGregor, R

    2001-01-01

    Veterinarians and farmers employing multivalent killed vaccines in lactating dairy cows have reported transient losses in milk production. Few studies have quantified this loss. In this report, effects of 2 commercially available 9-way vaccines on milk production and rectal temperature are examined. Repeated measures analyses of variance were used to compare changes in milk production and rectal temperature over time between treatment groups. There was a significant (P < 0.01) interaction among treatment and time when comparing vaccine- and placebo-treated animals. When pretreatment milk production (or days in milk) and pretreatment rectal temperature were considered, respectively, as covariates, a significant (P < 0.05) depression of milk production and a significant (P < 0.05) increase in rectal temperature were observed one day following injection. These effects were small and short-lived. The stage of lactation, level of milk production, and choice of product may be used as decision-making tools to decrease milk production losses in vaccine-candidate cows. PMID:11665428

  20. Technical note: unsafe rectal temperature measurements due to delayed warming of the thermocouple by using a condom. An issue concerning the estimation of the postmortem interval by using Henßge's nomogram.

    PubMed

    Krap, Tristan; Meurs, Joris; Boertjes, Janine; Duijst, Wilma

    2016-03-01

    In some cases, in the Netherlands, an additional layer is being added to the thermocouple, used to measure the rectal temperature in medicolegal death investigations. Because of this deviation from the standard method, questions arose regarding the accuracy and precision of the measured temperature. Therefore, a cooling experiment was carried out on a round body made of agar with an average thermal conductivity of 0.454 W/(m °C) while measuring the temperature with and without an additional layer around the thermocouple for three different starting temperatures: 36, 30, and 27 °C. The results show a significant difference between the measured values for the first 5 min when comparing with and without the additional layer. Further, a decrease in precision is present within the first minutes when using an additional layer. Therefore, it is concluded that it is best to measure the rectal temperature without an additional layer around the thermocouple and caution should be taken when measuring with an additional layer.

  1. A Comparison of Surface Infrared with Rectal Thermometry in Dogs.

    PubMed

    Omóbòwálé, T O; Ogunro, B N; Odigie, E A; Otuh, P I; Olugasa, B O

    2017-12-30

    Accurate determination of temperature is crucial in the diagnosis of febrile conditions. Although fewer techniques have proven as useful and reliable a predictor of core body temperature as the rectal thermometry, the process of obtaining the rectal temperature could be stressful in dogs. The infrared thermometry is a noncontact device used for measuring body temperature, with advantages which include speed, convenience, and reduced stress to the animals and reduced occupational risks to the animal handler. Therefore, there is the need to assess the consistency and agreement between non-contact infrared thermometry and traditional rectal thermometry in body temperature estimation. This study compared and assessed the sensitivity of non-contact infrared thermometer used on the forehead and nasal regions respectively with that of a rectal thermometer in dogs for body temperature estimation. One hundred and thirty (130) dogs presented for veterinary attention at the Veterinary Teaching Hospital (VTH), University of Ibadan, Nigeria were enrolled in this study during August to September 2014, irrespective of sex, age, breed or health status. Temperatures of dogs presented at the clinic were obtained using both multiple non-contact infrared thermometric measures obtained in the nasal and frontal head regions; and by rectal temperature. A multivariate cross-matrix analysis was used to assess the difference in measurements between the rectal thermometry and non-contact infrared thermometry. Descriptive statistics was used to compare variation and trend regularity of the nasal and fore-head infrared thermometry. A logistic regression of the difference in measurements was computed at 95% confidence interval and P<0.05. The mean difference revealed that the rectal temperature was 5.330C higher than the non-contact infrared forehead-based temperature and 7.570C higher than nasal-based temperature measurements respectively. The Bland-Altman (B-A) plot showed that the 95% limits

  2. Genomic evaluation of rectal temperature in Holstein cattle

    USDA-ARS?s Scientific Manuscript database

    Heat stress negatively impacts the production, fertility, and health of dairy cattle. Rectal temperature (RT) has unfavorable genetic correlations with production, longevity, economic merit, and somatic cell score in Holstein cows. The objectives of the current study were to perform a genome-wide as...

  3. Relationship between temperament and transportation with rectal temperature and secretion of cortisol and epinephrine in bulls

    USDA-ARS?s Scientific Manuscript database

    This study investigated whether temperament influences rectal temperature and the secretion of cortisol and epinephrine in response to transportation. Brahman bulls were selected based on temperament score (average of exit velocity, EV, and pen score, PS) measured 28 days prior to weaning with the 8...

  4. Eye and Ear Temperature Using Infrared Thermography Are Related to Rectal Temperature in Dogs at Rest or With Exercise

    PubMed Central

    Zanghi, Brian M.

    2016-01-01

    Rectal body temperature (BT) has been documented in exercising dogs to monitor thermoregulation, heat stress risk, and performance during physical activity. Eye (BTeye) and ear (BTear) temperature measured with infrared thermography (IRT) were compared to rectal (BTrec) temperature as the reference method and assess alternative sites to track hyperthermia, possibly to establish BTeye IRT as a passive and non-contact method. BT measures were recorded at 09:00, 11:30, 12:30, and 02:30 from Labrador Retrievers (N = 16) and Beagles (N = 16) while sedentary and with 30-min play-exercise (pre- and 0, 15, 30-min post-exercise). Total exercise locomotor activity counts were recorded to compare relative intensity of play-exercise between breeds. BTrec, BTeye, and BTear were measured within 5 min of the target time. Each BT method was analyzed by analysis of variance for main effects of breed and time. Method differences were compared using Bland–Altman plots and linear regression. Sedentary BT differed by breed for BTrec (p < 0.0001), BTear (p < 0.0001), and BTeye (p = 0.06) with Labs having on average 0.3–0.8°C higher BT compared to Beagles. Readings also declined over time for BTeye (p < 0.0001) and BTear (p < 0.0001), but not for BTrec (p = 0.63) for both breeds. Total exercise (30-min) activity counts did not differ (p = 0.53) between breeds. Time and breed interaction was significant in response to exercise for both BTrec and BTear (p = 0.035 and p = 0.005, respectively), with a marginal interaction (p = 0.09) for BTeye. All the three methods detected hyperthermia with Labs having a higher increase compared to Beagles. Both BTear and BTeye were significantly (p < 0.0001) related to BTrec in all dogs with sedentary or exercise activity. The relationship between BTeye and BTrec improved when monitoring exercise hyperthermia (r = 0.674) versus measures at rest (r = 0.381), whereas BTear was significantly

  5. Comparison of Digital Rectal and Microchip Transponder Thermometry in Ferrets (Mustela putorius furo)

    PubMed Central

    Maxwell, Branden M; Brunell, Marla K; Olsen, Cara H; Bentzel, David E

    2016-01-01

    Body temperature is a common physiologic parameter measured in both clinical and research settings, with rectal thermometry being implied as the ‘gold standard.’ However, rectal thermometry usually requires physical or chemical restraint, potentially causing falsely elevated readings due to animal stress. A less stressful method may eliminate this confounding variable. The current study compared 2 types of digital rectal thermometers—a calibrated digital thermometer and a common digital thermometer—with an implantable subcutaneous transponder microchip. Microchips were implanted subcutaneously between the shoulder blades of 16 ferrets (8 male, 8 female), and temperatures were measured twice from the microchip reader and once from each of the rectal thermometers. Results demonstrated the microchip temperature readings had very good to good correlation and agreement to those from both of the rectal thermometers. This study indicates that implantable temperature-sensing microchips are a reliable alternative to rectal thermometry for monitoring body temperature in ferrets. PMID:27177569

  6. Associations among milk production and rectal temperature on pregnancy maintenance in lactating recipient dairy cows.

    PubMed

    Vasconcelos, J L M; Cooke, R F; Jardina, D T G; Aragon, F L; Veras, M B; Soriano, S; Sobreira, N; Scarpa, A B

    2011-09-01

    The objective of this study was to evaluate the associations among milk production, rectal temperature, and pregnancy maintenance in lactating recipient dairy cows. Data were collected during an 11-mo period from 463 Holstein cows (203 primiparous and 260 multiparous) assigned to a fixed-time embryo transfer (ET) protocol. Only cows detected with a visible corpus luteum immediately prior to ET were used. Rectal temperatures were collected from all cows on the same day of ET. Milk production at ET was calculated by averaging individual daily milk production during the 7d preceding ET. Pregnancy diagnosis was performed by transrectal ultrasonography 21d after ET. Cows were ranked and assigned to groups according to median milk production (median=35kg/d; HPROD=above median; LPROD=below median) and rectal temperature (≤39.0°C=LTEMP; >39.0°C=HTEMP). A milk production×temperature group interaction was detected (P=0.04) for pregnancy analysis because HTEMP cows ranked as LPROD were 3.1 time more likely to maintain pregnancy compared with HTEMP cows ranked as HPROD (P=0.03). Milk production did not affect (P=0.55) odds of pregnancy maintenance within LTEMP cows, however, and no differences in odds of pregnancy maintenance were detected between HTEMP and LTEMP within milk production groups (P>0.11). Within HTEMP cows, increased milk production decreased the probability of pregnancy maintenance linearly, whereas within LTEMP cows, increased milk production increased the probability of pregnancy maintenance linearly. Within HPROD, increased rectal temperature decreased the probability of pregnancy maintenance linearly, whereas within LPROD cows, no associations between rectal temperatures and probability of cows to maintain pregnancy were detected. In summary, high-producing dairy cows with rectal temperatures below 39.0°C did not experience reduced pregnancy maintenance to ET compared to cohorts with reduced milk production. Copyright © 2011 Elsevier B.V. All rights

  7. A non invasive wearable sensor for the measurement of brain temperature.

    PubMed

    Dittmar, A; Gehin, C; Delhomme, G; Boivin, D; Dumont, G; Mott, C

    2006-01-01

    As the thermoregulation centres are deep in the brain, the cerebral temperature is one of the most important markers of fever, circadian rhythms physical and mental activities. However due to a lack of accessibility, the brain temperature is not easily measured. The axillary, buccal, tympanic and rectal temperatures do not reflect exactly the cerebral temperature. Nevertheless the rectal temperature is used as probably the most reliable indicator of the core body temperature. The brain temperature can be measured using NMR spectroscopy, microwave radiometry, near infrared spectroscopy, ultra-sound thermometry. However none of those methods are amenable to long term ambulatory use outside of the laboratory or of the hospital during normal daily activities, sport, etc. The brain core temperature "BCT" sensor, developed by the Biomedical Microsensors dpt of LPM at INSA-Lyon is a flexible active sensor using "zero-heat-flow" principle. The sensor has been used for experimental measurement: brain temperature during mental activity, and in hospital for the study of circadian rhythms. The results are in agreement with the measurement by the rectal probe. There are 2 versions of this sensor: a non ambulatory for the use in hospitals, and an ambulatory version using teletransmission. We are working for improving the autonomy of the ambulatory version up to several days. This wearable biomedical sensor (WBS) can be used for circadian assessment for chronobiology studies and in medical therapies.

  8. Relationships Between Temperament and Transportation With Rectal Temperature and Serum Concentrations of Cortisol and Epinephrine in Bulls

    USDA-ARS?s Scientific Manuscript database

    This study investigated whether temperament influences rectal temperature and serum concentrations of cortisol and epinephrine in response to transportation. Brahman bulls were selected based on temperament score (average of exit velocity, EV, and pen score, PS) measured 28 days prior to weaning wit...

  9. Rectal temperature-based death time estimation in infants.

    PubMed

    Igari, Yui; Hosokai, Yoshiyuki; Funayama, Masato

    2016-03-01

    In determining the time of death in infants based on rectal temperature, the same methods used in adults are generally used. However, whether the methods for adults are suitable for infants is unclear. In this study, we examined the following 3 methods in 20 infant death cases: computer simulation of rectal temperature based on the infinite cylinder model (Ohno's method), computer-based double exponential approximation based on Marshall and Hoare's double exponential model with Henssge's parameter determination (Henssge's method), and computer-based collinear approximation based on extrapolation of the rectal temperature curve (collinear approximation). The interval between the last time the infant was seen alive and the time that he/she was found dead was defined as the death time interval and compared with the estimated time of death. In Ohno's method, 7 cases were within the death time interval, and the average deviation in the other 12 cases was approximately 80 min. The results of both Henssge's method and collinear approximation were apparently inferior to the results of Ohno's method. The corrective factor was set within the range of 0.7-1.3 in Henssge's method, and a modified program was newly developed to make it possible to change the corrective factors. Modification A, in which the upper limit of the corrective factor range was set as the maximum value in each body weight, produced the best results: 8 cases were within the death time interval, and the average deviation in the other 12 cases was approximately 80min. There was a possibility that the influence of thermal isolation on the actual infants was stronger than that previously shown by Henssge. We conclude that Ohno's method and Modification A are useful for death time estimation in infants. However, it is important to accept the estimated time of death with certain latitude considering other circumstances. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  10. Rectal temperature changes and oxygen toxicity in dogs treated in a monoplace chamber.

    PubMed

    Shmalberg, Justin; Davies, Wendy; Lopez, Stacy; Shmalberg, Danielle; Zilberschtein, Jose

    2015-01-01

    Hyperbaric oxygen treatments are increasingly administered to pet dogs, using veterinary-specific monoplace chambers. The basic physiologic responses, chamber performance and oxygen toxicity rates have not yet been evaluated in dogs in a clinical setting. As a result, a series of consecutive 45-minute, 2-atmospheres absolute (atm abs) hyperbaric treatments with 100% oxygen were evaluated in a veterinary rehabilitation center (n = 285). 65 dogs with a mean body weight of 21 ± 15 kg (1.4-71 kg) were treated with an average of four sessions each. The mean rectal temperature of canine patients decreased 0.07 degrees C (0.1 degrees F) during treatments (p = 0.04). Intra-chamber temperature and humidity both increased: +1.0 degrees C (1.7 degrees F, p < 0.0001) and +5.7% (p < 0.0001), respectively. The mean maximal oxygen concentration measured before depressurization of the veterinary-specific commercial chamber was 98.0 ± 0.9%. No strong correlations (r > 0.75) were identified between body weights, body condition scores, maximal oxygen concentrations, starting or ending rectal temperature, chamber humidity and chamber temperature. Oxygen toxicity was not observed during the observational period. Patients were most commonly treated for intervertebral disc disease (n = 16 dogs) and extensive traumatic wounds (n = 10 dogs), which represented a large number of the total study sessions (19% and 16%, respectively).

  11. Eye and Ear Temperature Using Infrared Thermography Are Related to Rectal Temperature in Dogs at Rest or With Exercise.

    PubMed

    Zanghi, Brian M

    2016-01-01

    Rectal body temperature (BT) has been documented in exercising dogs to monitor thermoregulation, heat stress risk, and performance during physical activity. Eye (BT eye ) and ear (BT ear ) temperature measured with infrared thermography (IRT) were compared to rectal (BT rec ) temperature as the reference method and assess alternative sites to track hyperthermia, possibly to establish BT eye IRT as a passive and non-contact method. BT measures were recorded at 09:00, 11:30, 12:30, and 02:30 from Labrador Retrievers ( N  = 16) and Beagles ( N  = 16) while sedentary and with 30-min play-exercise (pre- and 0, 15, 30-min post-exercise). Total exercise locomotor activity counts were recorded to compare relative intensity of play-exercise between breeds. BT rec , BT eye , and BT ear were measured within 5 min of the target time. Each BT method was analyzed by analysis of variance for main effects of breed and time. Method differences were compared using Bland-Altman plots and linear regression. Sedentary BT differed by breed for BT rec ( p  < 0.0001), BT ear ( p  < 0.0001), and BT eye ( p  = 0.06) with Labs having on average 0.3-0.8°C higher BT compared to Beagles. Readings also declined over time for BT eye ( p  < 0.0001) and BT ear ( p  < 0.0001), but not for BT rec ( p  = 0.63) for both breeds. Total exercise (30-min) activity counts did not differ ( p  = 0.53) between breeds. Time and breed interaction was significant in response to exercise for both BT rec and BT ear ( p  = 0.035 and p  = 0.005, respectively), with a marginal interaction ( p  = 0.09) for BT eye . All the three methods detected hyperthermia with Labs having a higher increase compared to Beagles. Both BT ear and BT eye were significantly ( p  < 0.0001) related to BT rec in all dogs with sedentary or exercise activity. The relationship between BT eye and BT rec improved when monitoring exercise hyperthermia ( r  = 0.674) versus measures at rest

  12. Glucose Infusion into Exercising Dogs after Confinement: Rectal and Active Muscle Temperatures

    NASA Technical Reports Server (NTRS)

    Greenleaf, J. E.; Kruk, B.; Nazar, K.; Falecka-Wieczorek, I.; Kaciuba-Uscilko, H.

    1995-01-01

    Intravenous glucose infusion into ambulatory dogs results in attenuation of exercise-induced increase of both rectal and thigh muscle temperatures. That glucose (Glu) infusion attenuates excessive increase in body temperature from restricted activity during confinement deconditioning. Intravenous glucose infusion attenuates the rise in exercise core temperature in deconditioned dogs by a yet undefined mechanism.

  13. Is oral temperature an accurate measurement of deep body temperature? A systematic review.

    PubMed

    Mazerolle, Stephanie M; Ganio, Matthew S; Casa, Douglas J; Vingren, Jakob; Klau, Jennifer

    2011-01-01

    Oral temperature might not be a valid method to assess core body temperature. However, many clinicians, including athletic trainers, use it rather than criterion standard methods, such as rectal thermometry. To critically evaluate original research addressing the validity of using oral temperature as a measurement of core body temperature during periods of rest and changing core temperature. In July 2010, we searched the electronic databases PubMed, Scopus, Cumulative Index to Nursing and Allied Health Literature (CINAHL), SPORTDiscus, Academic Search Premier, and the Cochrane Library for the following concepts: core body temperature, oral, and thermometers. Controlled vocabulary was used, when available, as well as key words and variations of those key words. The search was limited to articles focusing on temperature readings and studies involving human participants. Original research was reviewed using the Physiotherapy Evidence Database (PEDro). Sixteen studies met the inclusion criteria and subsequently were evaluated by 2 independent reviewers. All 16 were included in the review because they met the minimal PEDro score of 4 points (of 10 possible points), with all but 2 scoring 5 points. A critical review of these studies indicated a disparity between oral and criterion standard temperature methods (eg, rectal and esophageal) specifically as the temperature increased. The difference was -0.50°C ± 0.31°C at rest and -0.58°C ± 0.75°C during a nonsteady state. Evidence suggests that, regardless of whether the assessment is recorded at rest or during periods of changing core temperature, oral temperature is an unsuitable diagnostic tool for determining body temperature because many measures demonstrated differences greater than the predetermined validity threshold of 0.27°C (0.5°F). In addition, the differences were greatest at the highest rectal temperatures. Oral temperature cannot accurately reflect core body temperature, probably because it is

  14. Rectal temperature as an indicator for heat tolerance in chickens.

    PubMed

    Chen, Xing Y; Wei, Pei P; Xu, Shen Y; Geng, Zhao Y; Jiang, Run S

    2013-11-01

    High environmental temperature is perhaps the most important inhibiting factor to poultry production in hot regions. The objective of this study was to test adaptive responses of chickens to high ambient temperatures and identify suitable indicators for selection of heat-tolerant individuals. Full-sib or half-sib Anak-40 pullets (n = 55) with similar body weights were raised in a room with a temperature ranging from 24°C to 28°C, and relative humidity of 50% from 61 to 65 days of age. On day 66, the ambient temperature was increased within 60 min to 35 ± 1°C which was defined as the initial of heat stress (0 h). Rectal temperature (RT) was measured on each pullet at 0, 6, 18, 30, 42, 54 and 66 h. After 66 h the ambient temperature was increased within 30 min to 41 ± 1°C and survival time (HSST) as well as lethal rectal temperatures (LRT) were recorded for each individual. The gap between the RT and initial RT was calculated as ΔTn (ΔT6, ΔT18, ΔT30, ΔT42, ΔT54 and ΔT66), and the interval between LRT and initial RT as ΔTT, respectively. A negative correlation was found between HSST and ΔTn as well as ΔTT (rΔ T 18  = -0.28 and rΔ TT  = -0.31, respectively, P < 0.05; rΔT30  = -0.36, rΔ T 42  = -0.38, rΔT54  = -0.56, P < 0.01). Importantly, pullets with low ΔT18 showed a longer HSST (256.0 ± 208.4 min) than those with high ΔT18 (HSST = 123.7 ± 78.3 min). This observation suggested that the ΔT18 or early increment of RT under heat stress might be considered as a reliable indicator for evaluation of heat resistance in chickens. © 2013 Japanese Society of Animal Science.

  15. Assessment of an aural infrared sensor for body temperature measurement in children.

    PubMed

    Rhoads, F A; Grandner, J

    1990-02-01

    A newly marketed device measures body temperature using an ear probe that detects infrared radiation from the tympanic membrane. It is simple to use and gives a reading in 1-2 seconds. Its accuracy was evaluated in a group of children, aged 1 month through 10 years, by comparing it with either rectal (n = 65), or oral (n = 48) temperatures obtained with a standard electronic thermometer, IVAC (San Diego, CA). The average elapsed time between readings was 11 minutes. Overall, 60 rectal and 40 oral temperatures (88.5%) were higher with IVAC than with the aural sensor. The difference ranged from -0.7 degrees C to +2.5 degrees C. The correlations between the infrared ear-probe values and the rectal and oral temperature readings were 0.77 and 0.75, respectively. Because the average reading using the aural sensor was lower than that using the IVAC, the sensitivity of the aural sensor for detecting clinically important levels of fever was low. None of seven patients with a rectal temperature of 39 degrees C or more and only 7 of 27 with a rectal temperature of 38 degrees C or more were identified by the aural sensor as having temperatures above these cutoff levels. Similarly, none of three patients with an oral temperature of 39 degrees C or more and only three of eight with an oral temperature of 38 degrees C or more were identified correctly by the aural sensor. The authors conclude that the aural sensor is unsatisfactory for detecting clinically significant fevers in a pediatric outpatient setting.

  16. Cold-Water Immersion and the Treatment of Hyperthermia: Using 38.6°C as a Safe Rectal Temperature Cooling Limit

    PubMed Central

    Gagnon, Daniel; Lemire, Bruno B.; Casa, Douglas J.; Kenny, Glen P.

    2010-01-01

    Abstract Context: Cold-water immersion is recommended for the immediate field treatment of exertional heat stroke. However, concerns exist over potential overcooling of hyperthermic individuals during cold-water immersion. Objective: To evaluate the recommendation that removing previously hyperthermic individuals from a cold-water bath at a rectal temperature (Tre) of 38.6°C would attenuate overcooling. Design: Controlled laboratory study. Setting: University research laboratory. Patients or Other Participants: Participants included 6 men and 4 women (age  =  22 ± 3 years, height  =  172 ± 10 cm, mass  =  67.8 ± 10.7 kg, body fat percentage  =  17.1% ± 4.5%, maximum oxygen consumption  =  59.3 ± 8.7 mL·kg−1·min−1). Intervention(s): After exercising at an ambient temperature of 40.0°C for 38.5 ± 9.4 minutes, until Tre reached 39.5°C, participants were immersed in a 2.0°C circulated water bath until Tre decreased to either 37.5°C or 38.6°C. Subsequently, participants were removed from the water bath and recovered for 20 minutes at an ambient temperature of 25°C. Main Outcome Measure(s): Rectal and esophageal temperatures were measured continuously during the immersion and recovery periods. Results: Because of the experimental design, the overall time of immersion was greater during the 37.5°C trial (16.6 ± 5.7 minutes) than the 38.6°C trial (8.8 ± 2.6 minutes) (t9  =  −4.740, P  =  .001). During the recovery period after cold-water immersion, both rectal (F1,9  =  50.540, P < .001) and esophageal (F1,6  =  20.365, P  =  .007) temperatures remained greater in the 38.6°C trial than in the 37.5°C trial. This was evidenced by low points of 36.47°C ± 0.70°C and 37.19°C ± 0.71°C for rectal temperature (t9  =  2.975, P  =  .016) and of 35.67°C ± 1.27°C and 36.72°C ± 0.95°C for esophageal temperature (t6  =  3.963, P  =  .007) during the recovery period of the 37.5°C and

  17. Comparison of methods of temperature measurement in swine.

    PubMed

    Hanneman, S K; Jesurum-Urbaitis, J T; Bickel, D R

    2004-07-01

    The purpose of these experiments was to test the equivalence of pulmonary artery, urinary bladder, tympanic, rectal and femoral artery methods of temperature measurement in healthy and critically ill swine under clinical intensive care unit (ICU) conditions using a prospective, time series design. First, sensors were tested for error and sensitivity to change in temperature with a precision-controlled water bath and a laboratory-certified digital thermometer for temperatures 34-42 degrees C. There was virtually no systematic (bias) or random (precision) error (<0.2 degrees C). The bladder sensor had the slowest response time to change in temperature (105-120 s). Next, testing was done in an experimental porcine ICU in a non-profit research institution with four male, sedated, and mechanically ventilated domestic farm pigs. The in vivo experiments were conducted over periods of 41-168 h with temperatures measured every 1-5 s. The bladder, tympanic and rectal methods had unacceptable bias (>or=0.5 degrees C) and/or precision (>or=0.2 degrees C). Response time varied from 7 s with the femoral artery method to 280 s (4.7 min) with the tympanic method. We concluded that equivalence of the methods was insufficient for them to be used interchangeably in the porcine ICU. Intravascular monitoring of core body temperature produces optimal measurement of porcine temperature under varying conditions of physiological stability.

  18. Is Oral Temperature an Accurate Measurement of Deep Body Temperature? A Systematic Review

    PubMed Central

    Mazerolle, Stephanie M.; Ganio, Matthew S.; Casa, Douglas J.; Vingren, Jakob; Klau, Jennifer

    2011-01-01

    Context: Oral temperature might not be a valid method to assess core body temperature. However, many clinicians, including athletic trainers, use it rather than criterion standard methods, such as rectal thermometry. Objective: To critically evaluate original research addressing the validity of using oral temperature as a measurement of core body temperature during periods of rest and changing core temperature. Data Sources: In July 2010, we searched the electronic databases PubMed, Scopus, Cumulative Index to Nursing and Allied Health Literature (CINAHL), SPORTDiscus, Academic Search Premier, and the Cochrane Library for the following concepts: core body temperature, oral, and thermometers. Controlled vocabulary was used, when available, as well as key words and variations of those key words. The search was limited to articles focusing on temperature readings and studies involving human participants. Data Synthesis: Original research was reviewed using the Physiotherapy Evidence Database (PEDro). Sixteen studies met the inclusion criteria and subsequently were evaluated by 2 independent reviewers. All 16 were included in the review because they met the minimal PEDro score of 4 points (of 10 possible points), with all but 2 scoring 5 points. A critical review of these studies indicated a disparity between oral and criterion standard temperature methods (eg, rectal and esophageal) specifically as the temperature increased. The difference was −0.50°C ± 0.31°C at rest and −0.58°C ± 0.75°C during a nonsteady state. Conclusions: Evidence suggests that, regardless of whether the assessment is recorded at rest or during periods of changing core temperature, oral temperature is an unsuitable diagnostic tool for determining body temperature because many measures demonstrated differences greater than the predetermined validity threshold of 0.27°C (0.5°F). In addition, the differences were greatest at the highest rectal temperatures. Oral temperature cannot

  19. Detection of fever in children emergency care: comparisons of tactile and rectal temperatures in Nigerian children

    PubMed Central

    2010-01-01

    Background Clinical thermometry is the objective method for temperature measurements but tactile assessment of fever at home is usually the basis for seeking medical attention especially where the cost and level of literacy preclude the use of thermometers. This study was carried out to determine the reliability of tactile perception of fever by caregivers, nurses and house physicians in comparison to rectal thermometry and also the use of commonly practiced surface of the hand in the care of ill children. All caregivers of children aged 6 to 59 months who presented to the emergency department were approached consecutively at the triage stage but 182 children participated. Each child had tactile assessment of fever using palmar and dorsal surfaces of the hand by the caregivers, House Physicians and Nursing Officers. Rectal temperature was also measured and read independently by nurses and house physicians. Comparisons were made between tactile assessments and thermometer readings using a cut-off for fever, 38.0°C and above. Findings The caregivers' perception of fever had a sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of 95%, 23%, 66% and 73%, respectively compared with 93%, 26%, 67% and 69%, respectively for nursing officers. Irrespective of the groups studied, 77.1% of 336 assessors opined that the dorsal surface of the hand was more sensitive in tactile assessment of temperature and the frequently used site for assessment of fever were the head (35.6%) and neck (33.3%). Tactile assessment of temperature over-detected fever in ≥ 24% of cases among the three groups of assessors. Conclusions The present study suggests that tactile assessment of temperature may over estimate the prevalence of fever, it does not detect some cases and the need for objective measurement of temperature is emphasised in paediatric emergency care. PMID:20406473

  20. Comparison of Microchip Transponder and Noncontact Infrared Thermometry with Rectal Thermometry in Domestic Swine (Sus scrofa domestica)

    PubMed Central

    Jara, Amanda L; Hanson, Jarod M; Gabbard, Jon D; Johnson, Scott K; Register, Emery T; He, Biao

    2016-01-01

    During disease outbreaks, core temperature is a useful health metric in swine, due to the presence of pyrexia especially during the acute phase of infection. Despite technologic advances in other facets of swine production and health management, rectal thermometry continues to be the ‘gold standard’ for measuring core body temperature. However, for various reasons, collecting rectal temperatures can be difficult and unsafe depending on the housing modality. In addition, the delay between insertion of the rectal thermometer and obtaining a reading can affect measurement accuracy, especially when the pig requires physical restraint. Clearly safer, faster, and more accurate and precise temperature acquisition methods that necessitate minimal or no handling of swine are needed. We therefore compared rectal thermometers, subcutaneous microchips, and an inexpensive handheld infrared thermometer by measuring the core body temperature of 24 male castrated piglets at random intervals over a 5-wk period. The core body temperature (mean ± 1 SD) was 39.3 ± 0.5 °C by rectal thermometry, 39.0 ± 0.7 °C by microchip transponder, and 34.3 ± 1.0 °C by infrared thermometry; these 3 values differed significantly. Although the readings obtain by using infrared thermometry were numerically lower than those from the other methods, it is arguably the safest method for assessing the core temperature of swine and showed strong relative correlation with rectal temperature. PMID:27657715

  1. The predicting value of postoperative body temperature on long-term survival in patients with rectal cancer.

    PubMed

    Yu, Huichuan; Luo, Yanxin; Peng, Hui; Kang, Liang; Huang, Meijin; Luo, Shuangling; Chen, Wenhao; Yang, Zihuan; Wang, Jianping

    2015-09-01

    This study aimed to assess the association between postoperative body temperature and prognosis in patients with rectal cancer. Five hundred and seven patients with stage I to III rectal cancers were enrolled in the current study. Basal body temperature (BBT, measured at 6 am) and maximal body temperature (MBT) on each day after surgery were analyzed retrospectively. Patients were divided into two equal groups according to the median of BBT and MBT at each day. The primary end points were disease-free survival (DFS) and overall survival (OS). The univariate and multivariate analyses showed that patients with low D0-MBT (<37.4 °C) had lower 3-year DFS [adjusted hazard ratio (HR) 1.56 (95 % CI 1.08-2.24, P = 0.017)] as well as OS [adjusted HR 1.72 (95 % CI 1.05-2.82, P = 0.032)] rate as compared to those with high D0-MBT (>37.4 °C). In the subset of 318 patients with T3 stage tumor and the subgroup of 458 patients without blood transfusion as well, low D0-MBT continues to be an independent predictor of DFS/OS with an adjusted HR equal to 1.48 (95 % CI 1.02-2.24, P = 0.046)/1.68 (95 % CI 1.04-2.99, P = 0.048) and 1.45 (95 % CI 1.02-2.13, P = 0.048)/1.59 (95 % CI 1.01-2.74, P = 0.049), respectively. In addition, we found that patients have higher risk of 1-year recurrence if those were exhibiting low preoperative BBT (<36.6 °C) (17 vs. 10 %, P = 0.034). Low body temperature (D0-MBT < 37.4 °C) after surgery was an independent predictor of poor survival outcomes in patients with rectal cancer.

  2. Comparison of an in-helmet temperature monitor system to rectal temperature during exercise.

    PubMed

    Wickwire, P Jason; Buresh, Robert J; Tis, Laurie L; Collins, Mitchell A; Jacobs, Robert D; Bell, Marla M

    2012-01-01

    Body temperature monitoring is crucial in helping to decrease the amount and severity of heat illnesses; however, a practical method of monitoring temperature is lacking. In response to the lack of a practical method of monitoring the temperature of athletes, Hothead Technologies developed a device (HOT), which continuously monitors an athlete's fluctuations in body temperature. HOT measures forehead temperature inside helmets. The purpose of this study was to compare HOT against rectal temperature (Trec). Male volunteers (n = 29, age = 23.5 ± 4.5 years, weight = 83.8 ± 10.4 kg, height = 180.1 ± 5.8 cm, body fat = 12.3 ± 4.5%) exercised on a treadmill at an intensity of 60-75% heart rate reserve (HRR) (wet bulb globe temperature [WBGT] = 28.7° C) until Trec reached 38.7° C. The correlation between Trec and HOT was 0.801 (R = 0.64, standard error of the estimate (SEE) = 0.25, p = 0.00). One reason for this relatively high correlation is the microclimate that HOT is monitoring. HOT is not affected by the external climate greatly because of its location in the helmet. Therefore, factors such as evaporation do not alter HOT temperature to a great degree. HOT was compared with Trec in a controlled setting, and the exercise used in this study was moderate aerobic exercise, very unlike that used in football. In a controlled laboratory setting, the relationship between HOT and Trec showed favorable correlations. However, in applied settings, helmets are repeatedly removed and replaced forcing HOT to equilibrate to forehead temperature every time the helmet is replaced. Therefore, future studies are needed to mimic how HOT will be used in field situations.

  3. Effect of simulated ambient particulate matter exposure on performance, rectal temperature, and leukocytosis of young Spanish goats with or without tilmicosin phosphate.

    PubMed

    Chirase, N K; Purdy, C W; Avampato, J M

    2004-04-01

    Dust is an environmental stressor and can become extensive in agricultural production systems. Thirty-six female, Spanish goats (average BW 21.1 kg, SEM = 1.31; age = 4 mo) were randomly assigned to simulated dust events or no dust, with or without tilmicosin phosphate treatment in a 2 x 2 factorial arrangement of treatments to determine effects on performance, rectal temperature, and leukocyte changes. All goats were fed a standard growing diet (13.6% CP) consisting of 37% roughage and 63% concentrate (DM basis). Feed intake was measured daily, and BW (unshrunk) measured individually every 7 d. The tilmicosin-treated group received tilmicosin phosphate (10 mg/kg BW s.c.) before starting the study. Goats exposed to dust were enclosed as a group inside a canvass tent for 4 h each day and ground feed yard manure dust (mean particle size 100 microm) was aerosolized inside the tent to simulate a dust event. There was one single dust event (Phase I) followed by rectal temperature measurement, and heparinized blood collection for complete cell counts at 0 (pretrial), 4, 12, 20, 44, 68, and 210 h after dust exposure. This was followed by 21 d of chronic dust events (Phase II). The sampling procedures for Phase II were exactly the same as in Phase I, except that samples were obtained daily at 0 (before dust application), 4, 8, and 12 h after each dust event. Dust treatment had no effect (P > 0.05) on feed intake or ADG, but the gain:feed (G:F) ratio was lower (P < 0.05) in the control goats than the dust exposed group. Tilmicosin phosphate-treated goats had a higher (P < 0.05) G:F ratio than untreated goats. Dust exposure increased (P < 0.002), but tilmicosin treatment decreased (P < 0.05) rectal temperature at 4 and 8 h. Dust exposure increased (P < 0.02) blood lymphocyte counts compared with controls. These results suggest that simulated dust events altered rectal temperature and leukocyte counts of goats.

  4. Relationship between rectal temperature at first treatment for bovine respiratory disease complex in feedlot calves and the probability of not finishing the production cycle.

    PubMed

    Theurer, Miles E; White, Brad J; Larson, Robert L; Holstein, Krista K; Amrine, David E

    2014-12-01

    OBJECTIVE-To determine the relationship between rectal temperature at first treatment for bovine respiratory disease complex (BRDC) in feedlot calves and the probability of not finishing the production cycle. DESIGN-Retrospective data analysis. ANIMALS-344,982 calves identified as having BRDC from 19 US feedlots from 2000 to 2009. PROCEDURES-For each calf, data for rectal temperature at initial treatment for BRDC and various performance and outcome variables were analyzed. A binary variable was created to identify calves that did not finish (DNF) the production cycle (died or culled prior to cohort slaughter). A mixed general linear model and receiver operating characteristic curve were created to evaluate associations of rectal temperature, number of days in the feedlot at time of BRDC diagnosis, body weight, quarter of year at feedlot arrival, sex, and all 2-way interactions with rectal temperature with the probability that calves DNF. RESULTS-27,495 of 344,982 (7.97%) calves DNF. Mean rectal temperature at first treatment for BRDC was 40.0°C (104°F). As rectal temperature increased, the probability that a calf DNF increased; however, that relationship was not linear and was influenced by quarter of year at feedlot arrival, sex, and number of days in the feedlot at time of BRDC diagnosis. Area under the receiver operating characteristic curve for correct identification of a calf that DNF was 0.646. CONCLUSIONS AND CLINICAL RELEVANCE-Rectal temperature of feedlot calves at first treatment for BRDC had limited value as a prognostic indicator of whether those calves would finish the production cycle.

  5. The Influence of Feed Energy Density and a Formulated Additive on Rumen and Rectal Temperature in Hanwoo Steers

    PubMed Central

    Cho, Sangbuem; Mbiriri, David Tinotenda; Shim, Kwanseob; Lee, A-Leum; Oh, Seong-Jin; Yang, Jinho; Ryu, Chaehwa; Kim, Young-Hoon; Seo, Kang-Seok; Chae, Jung-Il; Oh, Young Kyoon; Choi, Nag-Jin

    2014-01-01

    The present study investigated the optimum blending condition of protected fat, choline and yeast culture for lowering of rumen temperature. The Box Benken experimental design, a fractional factorial arrangement, and response surface methodology were employed. The optimum blending condition was determined using the rumen simulated in vitro fermentation. An additive formulated on the optimum condition contained 50% of protected fat, 25% of yeast culture, 5% of choline, 7% of organic zinc, 6.5% of cinnamon, and 6.5% of stevioside. The feed additive was supplemented at a rate of 0.1% of diet (orchard grass:concentrate, 3:7) and compared with a control which had no additive. The treatment resulted in lower volatile fatty acid (VFA) concentration and biogas than the control. To investigate the effect of the optimized additive and feed energy levels on rumen and rectal temperatures, four rumen cannulated Hanwoo (Korean native beef breed) steers were in a 4×4 Latin square design. Energy levels were varied to low and high by altering the ratio of forage to concentrate in diet: low energy (6:4) and high energy (4:6). The additive was added at a rate of 0.1% of the diet. The following parameters were measured; feed intake, rumen and rectal temperatures, ruminal pH and VFA concentration. This study was conducted in an environmentally controlled house with temperature set at 30°C and relative humidity levels of 70%. Steers were housed individually in raised crates to facilitate collection of urine and feces. The adaptation period was for 14 days, 2 days for sampling and 7 days for resting the animals. The additive significantly reduced both rumen (p<0.01) and rectal temperatures (p<0.001) without depressed feed intake. There were interactions (p<0.01) between energy level and additive on ruminal temperature. Neither additive nor energy level had an effect on total VFA concentration. The additive however, significantly increased (p<0.01) propionate and subsequently had lower

  6. The influence of feed energy density and a formulated additive on rumen and rectal temperature in hanwoo steers.

    PubMed

    Cho, Sangbuem; Mbiriri, David Tinotenda; Shim, Kwanseob; Lee, A-Leum; Oh, Seong-Jin; Yang, Jinho; Ryu, Chaehwa; Kim, Young-Hoon; Seo, Kang-Seok; Chae, Jung-Il; Oh, Young Kyoon; Choi, Nag-Jin

    2014-11-01

    The present study investigated the optimum blending condition of protected fat, choline and yeast culture for lowering of rumen temperature. The Box Benken experimental design, a fractional factorial arrangement, and response surface methodology were employed. The optimum blending condition was determined using the rumen simulated in vitro fermentation. An additive formulated on the optimum condition contained 50% of protected fat, 25% of yeast culture, 5% of choline, 7% of organic zinc, 6.5% of cinnamon, and 6.5% of stevioside. The feed additive was supplemented at a rate of 0.1% of diet (orchard grass:concentrate, 3:7) and compared with a control which had no additive. The treatment resulted in lower volatile fatty acid (VFA) concentration and biogas than the control. To investigate the effect of the optimized additive and feed energy levels on rumen and rectal temperatures, four rumen cannulated Hanwoo (Korean native beef breed) steers were in a 4×4 Latin square design. Energy levels were varied to low and high by altering the ratio of forage to concentrate in diet: low energy (6:4) and high energy (4:6). The additive was added at a rate of 0.1% of the diet. The following parameters were measured; feed intake, rumen and rectal temperatures, ruminal pH and VFA concentration. This study was conducted in an environmentally controlled house with temperature set at 30°C and relative humidity levels of 70%. Steers were housed individually in raised crates to facilitate collection of urine and feces. The adaptation period was for 14 days, 2 days for sampling and 7 days for resting the animals. The additive significantly reduced both rumen (p<0.01) and rectal temperatures (p<0.001) without depressed feed intake. There were interactions (p<0.01) between energy level and additive on ruminal temperature. Neither additive nor energy level had an effect on total VFA concentration. The additive however, significantly increased (p<0.01) propionate and subsequently had lower

  7. Heritability of rectal temperature and genetic correlations with production and reproduction traits in dairy cattle

    USDA-ARS?s Scientific Manuscript database

    Genetic selection for body temperature regulation during heat stress might be a useful approach to reduce the magnitude of heat stress effects on production and reproduction. Present objectives were to estimate the genetic parameters of rectal temperature in dairy cows reared in free stall barns und...

  8. Effects of electromagnetic radiation (bright light, extremely low-frequency magnetic fields, infrared radiation) on the circadian rhythm of melatonin synthesis, rectal temperature, and heart rate.

    PubMed

    Griefahn, Barbara; Künemund, Christa; Blaszkewicz, Meinolf; Lerchl, Alexander; Degen, Gisela H

    2002-10-01

    Electromagnetic spectra reduce melatonin production and delay the nadirs of rectal temperature and heart rate. Seven healthy men (16-22 yrs) completed 4 permuted sessions. The control session consisted of a 24-hours bedrest at < 30 lux, 18 degrees C, and < 50 dBA. In the experimental sessions, either light (1500 lux), magnetic field (16.7 Hz, 0.2 mT), or infrared radiation (65 degrees C) was applied from 5 pm to 1 am. Salivary melatonin level was determined hourly, rectal temperature and heart rate were continuously recorded. Melatonin synthesis was completely suppressed by light but resumed thereafter. The nadirs of rectal temperature and heart rate were delayed. The magnetic field had no effect. Infrared radiation elevated rectal temperature and heart rate. Only bright light affected the circadian rhythms of melatonin synthesis, rectal temperature, and heart rate, however, differently thus causing a dissociation, which might enhance the adverse effects of shiftwork in the long run.

  9. Development of a method for estimating oesophageal temperature by multi-locational temperature measurement inside the external auditory canal

    NASA Astrophysics Data System (ADS)

    Nakada, Hirofumi; Horie, Seichi; Kawanami, Shoko; Inoue, Jinro; Iijima, Yoshinori; Sato, Kiyoharu; Abe, Takeshi

    2017-09-01

    We aimed to develop a practical method to estimate oesophageal temperature by measuring multi-locational auditory canal temperatures. This method can be applied to prevent heatstroke by simultaneously and continuously monitoring the core temperatures of people working under hot environments. We asked 11 healthy male volunteers to exercise, generating 80 W for 45 min in a climatic chamber set at 24, 32 and 40 °C, at 50% relative humidity. We also exposed the participants to radiation at 32 °C. We continuously measured temperatures at the oesophagus, rectum and three different locations along the external auditory canal. We developed equations for estimating oesophageal temperatures from auditory canal temperatures and compared their fitness and errors. The rectal temperature increased or decreased faster than oesophageal temperature at the start or end of exercise in all conditions. Estimated temperature showed good similarity with oesophageal temperature, and the square of the correlation coefficient of the best fitting model reached 0.904. We observed intermediate values between rectal and oesophageal temperatures during the rest phase. Even under the condition with radiation, estimated oesophageal temperature demonstrated concordant movement with oesophageal temperature at around 0.1 °C overestimation. Our method measured temperatures at three different locations along the external auditory canal. We confirmed that the approach can credibly estimate the oesophageal temperature from 24 to 40 °C for people performing exercise in the same place in a windless environment.

  10. Temperature measurement from the brain and rectum in charred corpses: a pilot study on an animal model.

    PubMed

    Gibelli, Daniele; Cantatore, Angela; Porta, Davide; Poppa, Pasquale; Sala, Remo; Marco, Grandi; Cattaneo, Cristina

    2014-03-01

    Measurement of body temperature provides relevant data on postmortem interval, and different studies have been so far attempted to apply temperature assessment methods also under extreme environmental conditions; however, none of them has been performed yet on charred or heated bodies, where temperature measurement is presumed to be unreliable because of the possible influence of heating. This study aimed at verifying any possible early-stage alterations of rectal and endocranial temperature due to fire on an animal model during the charring process. Three pigs, 2 adults (pigs 1 and 2) whose weight was about 50 kg each and 1 piglet weighing 3 kg, were heated and burnt on a natural fire lit on top of a wooden stack, without the use of accelerants; 2 thermocouples were positioned in the rectum and in the cranium to record second-by-second rectal and endocranial temperature values. Results demonstrate that the rectal temperature does not seem to increase in adult pigs for 40 to 50 minutes after the body has been exposed to fire, probably because of the thermal insulating characteristics of the adipose tissue. Therefore, temperature may still be of some help for estimating postmortem interval on heated or burnt cadavers.

  11. Differences between sexes in rectal cooling rates after exercise-induced hyperthermia.

    PubMed

    Lemire, Bruno B; Gagnon, Daniel; Jay, Ollie; Kenny, Glen P

    2009-08-01

    We evaluated differences between sexes in core cooling rates during cold water immersion after exercise-induced hyperthermia. Ten male (M) and nine female (F) participants, matched for body surface area-to-mass ratio (AD/M) (F: 268 +/- 19 vs M: 261 +/- 16 cm2 x kg(-1)), were recruited for the study. Participants exercised until rectal temperature reached 39.5 degrees C and were subsequently immersed in a 2.0 degrees C circulated water bath until rectal temperature decreased to 37.5 degrees C. Rectal and mean skin temperatures and the relative rate of nonevaporative heat loss (W x m(-2)) were measured continuously during the immersion period. Males were heavier, had a lower body fat percentage, and had a greater amount of lean body mass compared with females (P < or = 0.05). Significant differences were found in the overall cooling rate for rectal temperature (F: 0.22 +/- 0.07 vs M: 0.12 +/- 0.03 degrees C x min(-1), P = 0.001) and in the overall immersion times (F: 10.89 +/- 4.49 vs M: 18.13 +/- 4.47 min, P = 0.003). Mean skin temperature was lower in females compared with that in males during the immersion period (P < 0.001), although there were no differences between sexes in the rate of nonevaporative heat loss (P = 0.180). Although females had a similar AD/M and greater body adiposity, they had approximately 1.7-fold greater rectal cooling rate. Because AD/M and body adiposity do not seem to influence rectal cooling rates in previously hyperthermic individuals, the greater cooling rates in females may be attributed to physical differences in lean body mass.

  12. Temporal artery thermometry in children younger than 5 years: a comparison with rectal thermometry.

    PubMed

    Odinaka, Kelechi K; Edelu, Benedict O; Nwolisa, Charles E; Amamilo, Ifeyinwa B; Okolo, Seline N

    2014-12-01

    Temporal artery (TA) thermometry has come as one of the new methods for temperature measurement, especially in children in whom accurate temperature monitoring can save lives. The device which is convenient and simple to use is yet to gain popularity in several parts of the world, as there are conflicting reports of its accuracy. This study compares the accuracy of the TA thermometry in children younger than 5 years using the rectal thermometry as the gold standard. Temperature was measured simultaneously in eligible children younger than 5 years from the forehead and rectum using the TA thermometer (TAT-2000C Exergen, USA) and standard mercury in glass rectal thermometer, respectively. The difference between the mean temperatures obtained by the 2 thermometry methods was tested using the paired t test. Pearson correlation coefficient, linear regression, and Bland-Altman plot were also used to test the relationship and agreement between the 2 instruments. The sensitivity, specificity, and positive and negative predictive values were also calculated. Overall, the mean TA temperature (37.80°C ± 1.07°C) was significantly lower than the mean rectal temperature (38.07°C ± 0.95°C), P < 0.001. In neonates, however, the mean difference was not significant, 0.02 ± 0.59 (P = 0.810). There was a significant positive correlation between the rectal and the temporal temperatures (r = 0.80, P < 0.01). The Bland-Altman plot showed wide variation in the limit of agreement between the rectal and the TA temperatures which ranged from -1.02°C to +1.56°C. The sensitivity of the TA thermometer was 64.6% and 83.5%, respectively, at a TA fever cutoff of 38.0°C and 37.7°C. Temporal artery thermometer is not accurate enough for the measurement of core body temperature in children younger than 5 years. However, it may be used as a tool for screening for fever in very busy clinics and emergency room at a fever cutoff of 37.7°C.

  13. Circadian rhythms in bed rest: Monitoring core body temperature via heat-flux approach is superior to skin surface temperature.

    PubMed

    Mendt, Stefan; Maggioni, Martina Anna; Nordine, Michael; Steinach, Mathias; Opatz, Oliver; Belavý, Daniel; Felsenberg, Dieter; Koch, Jochim; Shang, Peng; Gunga, Hanns-Christian; Stahn, Alexander

    2017-01-01

    Continuous recordings of core body temperature (CBT) are a well-established approach in describing circadian rhythms. Given the discomfort of invasive CBT measurement techniques, the use of skin temperature recordings has been proposed as a surrogate. More recently, we proposed a heat-flux approach (the so-called Double Sensor) for monitoring CBT. Studies investigating the reliability of the heat-flux approach over a 24-hour period, as well as comparisons with skin temperature recordings, are however lacking. The first aim of the study was therefore to compare rectal, skin, and heat-flux temperature recordings for monitoring circadian rhythm. In addition, to assess the optimal placement of sensor probes, we also investigated the effect of different anatomical measurement sites, i.e. sensor probes positioned at the forehead vs. the sternum. Data were collected as part of the Berlin BedRest study (BBR2-2) under controlled, standardized, and thermoneutral conditions. 24-hours temperature data of seven healthy males were collected after 50 days of -6° head-down tilt bed-rest. Mean Pearson correlation coefficients indicated a high association between rectal and forehead temperature recordings (r > 0.80 for skin and Double Sensor). In contrast, only a poor to moderate relationship was observed for sensors positioned at the sternum (r = -0.02 and r = 0.52 for skin and Double Sensor, respectively). Cross-correlation analyses further confirmed the feasibility of the forehead as a preferred monitoring site. The phase difference between forehead Double Sensor and rectal recordings was not statistically different from zero (p = 0.313), and was significantly smaller than the phase difference between forehead skin and rectal temperatures (p = 0.016). These findings were substantiated by cosinor analyses, revealing significant differences for mesor, amplitude, and acrophase between rectal and forehead skin temperature recordings, but not between forehead Double Sensor and rectal

  14. Axillary and thoracic skin temperatures poorly comparable to core body temperature circadian rhythm: results from 2 adult populations.

    PubMed

    Thomas, Karen A; Burr, Robert; Wang, Shu-Yuann; Lentz, Martha J; Shaver, Joan

    2004-01-01

    Data from 2 separate studies were used to examine the relationships of axillary or thoracic skin temperature to rectal temperature and to determine the phase relationships of the circadian rhythms of these temperatures. In study 1, axillary skin and rectal temperatures were recorded in 19 healthy women, 21 to 36 years of age. In study 2, thoracic skin and rectal temperatures were recorded in 74 healthy women, 39 to 59 years of age. In both studies, temperatures were recorded continuously for 24 h while subjects carried out normal activities. Axillary and thoracic probes were insulated purposely to prevent ambient effects. Cosinor analysis was employed to estimate circadian rhythm mesor, amplitude, and acrophase. In addition, correlations between temperatures at various measurement sites were calculated and agreement determined. The circadian timing of axillary and skin temperature did not closely approximate that of rectal temperature: the mean acrophase (clock time) for study 1 was 18:57 h for axillary temperature and 16:12 h for rectal; for study 2, it was 03:05 h for thoracic and 15:05 h for rectal. Across individual subjects, the correlations of axillary or thoracic temperatures with rectal temperatures were variable. Results do not support the use of either axillary or skin temperature as a substitute for rectal temperature in circadian rhythm research related to adult women.

  15. Oral administration of a medium containing both D-aspartate-producing live bacteria and D-aspartate reduces rectal temperature in chicks.

    PubMed

    Do, P H; Tran, P V; Bahry, M A; Yang, H; Han, G; Tsuchiya, A; Asami, Y; Furuse, M; Chowdhury, V S

    2017-10-01

    1. The aim of this study was to investigate the effects on the rectal temperature of young chicks of the oral administration of a medium that contained both live bacteria that produce D-aspartate (D-Asp) and D-Asp. 2. In Experiment 1, chicks were subjected to chronic oral administration of either the medium (containing live bacteria and 2.46 μmol D-Asp) or water from 7 to 14 d of age. Plasma-free amino acids as well as mitochondrial biogenic gene expression in the breast muscle were analysed. In Experiment 2, 7-d-old chicks were subjected to acute oral administration of the above medium or of an equimolar amount of D-Asp to examine their effect on changes in rectal temperature. In Experiment 3, after 1 week of chronic oral administration of the medium, 14-d-old chicks were exposed to either high ambient temperature (HT; 40 ± 1°C, 3 h) or control thermoneutral temperature (CT; 30 ± 1°C, 3 h) to monitor the changes in rectal temperature. 3. Chronic, but not acute, oral administration of the medium significantly reduced rectal temperature in chicks, and a chronic effect also appeared under HT conditions. 4. Chronic oral administration of the medium significantly reduced the mRNA abundance of the avian uncoupling protein (avUCP) in the breast muscle, but led to a significant increase in avian adenine nucleotide translocator (avANT) mRNA in the same muscle. 5. (a) These results indicate that the medium can reduce body temperature through the decline in avUCP mRNA expression in the breast muscle that may be involved in reduced mitochondrial proton leaks and heat production. (b) The increase in avANT further suggests a possible enhancement of adenosine triphosphate (ATP) synthesis.

  16. Comparison of Rectal and Aural Core Body Temperature Thermometry in Hyperthermic, Exercising Individuals: A Meta-Analysis

    PubMed Central

    Huggins, Robert; Glaviano, Neal; Negishi, Naoki; Casa, Douglas J.; Hertel, Jay

    2012-01-01

    Objective: To compare mean differences in core body temperature (Tcore) as assessed via rectal thermometry (Tre) and aural thermometry (Tau) in hyperthermic exercising individuals. Data Sources: PubMed, Ovid MEDLINE, SPORTDiscus, CINAHL, and Cochrane Library in English from the earliest entry points to August 2009 using the search terms aural, core body temperature, core temperature, exercise, rectal, temperature, thermistor, thermometer, thermometry, and tympanic. Study Selection: Original research articles that met these criteria were included: (1) concurrent measurement of Tre and Tau in participants during exercise, (2) minimum mean temperature that reached 38°C by at least 1 technique during or after exercise, and (3) report of means, standard deviations, and sample sizes. Data Extraction: Nine articles were included, and 3 independent reviewers scored these articles using the Physiotherapy Evidence Database (PEDro) scale (mean  =  5.1 ± 0.4). Data were divided into time periods pre-exercise, during exercise (30 to 180 minutes), and postexercise, as well as Tre ranges <37.99°C, 38.00°C to 38.99°C, and >39.00°C. Means and standard deviations for both measurement techniques were provided at all time intervals reported. Meta-analysis was performed to determine pooled and weighted mean differences between Tre and Tau. Data Synthesis: The Tre was conclusively higher than the Tau pre-exercise (mean difference [MD]  =  0.27°C, 95% confidence interval [CI]  =  0.15°C, 0.39°C), during exercise (MD  =  0.96°C, 95% CI  =  0.84°C, 1.08°C), and postexercise (MD  =  0.71°C, 95% CI  =  0.65°C, 0.78°C). As Tre measures increased, the magnitude of difference between the techniques also increased with an MD of 0.59°C (95% CI  =  0.53°C, 0.65°C) when Tre was <38°C; 0.79°C (95% CI  =  0.72°C, 0.86°C) when Tre was between 38.0°C and 38.99°C; and 1.72°C (95% CI  =  1.54°, 1.91°C) when Tre was >39.0°C. Conclusions

  17. Telemetric measurement of body core temperature in exercising unconditioned Labrador retrievers.

    PubMed

    Angle, T Craig; Gillette, Robert L

    2011-04-01

    This project evaluated the use of an ingestible temperature sensor to measure body core temperature (Tc) in exercising dogs. Twenty-five healthy, unconditioned Labrador retrievers participated in an outdoor 3.5-km run, completed in 20 min on a level, 400-m grass track. Core temperature was measured continuously with a telemetric monitoring system before, during, and after the run. Data were successfully collected with no missing data points during the exercise. Core temperature elevated in the dogs from 38.7 ± 0.3°C at pre-exercise to 40.4 ± 0.6°C post-exercise. While rectal temperatures are still the standard of measurement, telemetric core temperature monitors may offer an easier and more comfortable means of sampling core temperature with minimal human and mechanical interference with the exercising dog.

  18. Measurement of body temperature in 300 dogs with a novel noncontact infrared thermometer on the cornea in comparison to a standard rectal digital thermometer.

    PubMed

    Kreissl, Hannah; Neiger, Reto

    2015-01-01

    To assess the accuracy of obtaining body temperatures in dogs with a noncontact infrared thermometer (NCIT) on the cornea compared with a rectal digital thermometer (RDT). Prospective single center study. University teaching hospital. Three hundred dogs presented with low, normal, or high body temperatures. Three body temperature readings were measured by an RDT and by an NCIT on the cornea of the left eye by 2 investigators (experienced and inexperienced). Results obtained by the 2 methods were compared. Median body temperature measured by the experienced investigator with the RDT and the NCIT were 38.3°C (range 35.5°C-41.1°C; 95% CI: 38.2-38.4°C) and 37.7°C (35.9°C-40.1°C; 95% CI: 37.7°C-37.9°C), respectively. Measurement of RDT as well as of NCIT correlated well between both investigators (rRDT = 0.94; rNCIT = 0.82; respectively, P < 0.001 for both methods). Mean RDT and NCIT-temperature correlated poorly (r = 0.43; P < 0.001) when taken by the experienced investigator and even less by the nonexperienced investigator (r = 0.38; P < 0.001). Repeatability of the NCIT revealed an unsatisfactory value (0.24°C) compared to RDT measurement (0.12°C). Agreement between both devices in measuring low, normal, and high values, calculated by Cohens-Kappa, was unsatisfactory (к = 0.201; P < 0.001). Calculating the receiver operating characteristic curve to determine the best threshold for fever (defined as RDT temperature >39.0°C) showed an area under the curve of 0.76. Mean discomfort score was significantly lower using NCIT compared to RDT measurement (P < 0.001). There was poor agreement between body temperatures obtained by RDT and NCIT. The corneal NCIT measurement tends to underrecognize hypothermic and hyperthermic conditions. Although the use of the NCIT yields faster results and is significantly more comfortable for the dog than the RDT measurement, it cannot be recommended in dogs at this time. © Veterinary Emergency and Critical Care Society 2015.

  19. Tympanic ear thermometer assessment of body temperature among patients with cognitive disturbances. An acceptable and ethically desirable alternative?

    PubMed

    Aadal, Lena; Fog, Lisbet; Pedersen, Asger Roer

    2016-12-01

    Investigation of a possible relation between body temperature measurements by the current generation of tympanic ear and rectal thermometers. In Denmark, a national guideline recommends the rectal measurement. Subsequently, the rectal thermometers and tympanic ear devices are the most frequently used and first choice in Danish hospital wards. Cognitive changes constitute challenges with cooperating in rectal temperature assessments. With regard to diagnosing, ethics, safety and the patients' dignity, the tympanic ear thermometer might comprise a desirable alternative to rectal noninvasive measurement of body temperature during in-hospital-based neurorehabilitation. A prospective, descriptive cohort study. Consecutive inclusion of 27 patients. Linear regression models were used to analyse 284 simultaneous temperature measurements. Ethical approval for this study was granted by the Danish Data Protection Agency, and the study was completed in accordance with the Helsinki Declaration 2008. About 284 simultaneous rectal and ear temperature measurements on 27 patients were analysed. The patient-wise variability of measured temperatures was significantly higher for the ear measurements. Patient-wise linear regressions for the 25 patients with at least three pairs of simultaneous ear and rectal temperature measurements showed large interpatient variability of the association. A linear relationship between the rectal body temperature assessment and the temperature assessment employing the tympanic thermometer is weak. Both measuring methods reflect variance in temperature, but ear measurements showed larger variation. © 2016 Nordic College of Caring Science.

  20. Urine temperature as an index for the core temperature of industrial workers in hot or cold environments

    NASA Astrophysics Data System (ADS)

    Kawanami, Shoko; Horie, Seichi; Inoue, Jinro; Yamashita, Makiko

    2012-11-01

    Workers working in hot or cold environments are at risk for heat stroke and hypothermia. In Japan, 1718 people including 47 workers died of heat stroke in 2010 (Ministry of Health Labour and Welfare, Japan 2011). While the American Conference of Governmental Industrial Hygienists (ACGIH) recommendation lists the abnormal core temperature of workers as a criterion for halting work, no method has been established for reliably measuring core temperatures at workplaces. ISO 9886 (Ergonomics-evaluation of thermal strain by physiological measurements. ISO copyright office, Geneva, pp 3-14; 2004) recognizes urine temperature as an index of core temperature only at normal temperature. In this study we ascertained whether or not urine temperature could serve as an index for core temperature at temperatures above and below the ISO range. We measured urine temperature of 31 subjects (29.8 ± 11.9 years) using a thermocouple sensor placed in the toilet bowl at ambient temperature settings of 40, 20, and 5˚C, and compared them with rectal temperature. At all ambient temperature settings, urine temperature correlated closely with rectal temperature exhibiting small mean bias. Urine temperature changed in a synchronized manner with rectal temperature at 40˚C. A Bland and Altman analysis showed that the limits of agreement (mean bias ± 2SD) between rectal and urine temperatures were -0.39 to +0.15˚C at 40˚C (95%CI -0.44 to +0.20˚C) and -0.79 to +0.29˚C at 5˚C (-0.89 to +0.39˚C). Hence, urine temperature as measured by the present method is a practical surrogate index for rectal temperature and represents a highly reliable biological monitoring index for assessing hot and cold stresses of workers at actual workplaces.

  1. Telemetric measurement of body core temperature in exercising unconditioned Labrador retrievers

    PubMed Central

    Angle, T. Craig; Gillette, Robert L.

    2011-01-01

    This project evaluated the use of an ingestible temperature sensor to measure body core temperature (Tc) in exercising dogs. Twenty-five healthy, unconditioned Labrador retrievers participated in an outdoor 3.5-km run, completed in 20 min on a level, 400-m grass track. Core temperature was measured continuously with a telemetric monitoring system before, during, and after the run. Data were successfully collected with no missing data points during the exercise. Core temperature elevated in the dogs from 38.7 ± 0.3°C at pre-exercise to 40.4 ± 0.6°C post-exercise. While rectal temperatures are still the standard of measurement, telemetric core temperature monitors may offer an easier and more comfortable means of sampling core temperature with minimal human and mechanical interference with the exercising dog. PMID:21731189

  2. Prediction of rectal temperature using non-invasive physiologic variable measurements in hair pregnant ewes subjected to natural conditions of heat stress.

    PubMed

    Vicente-Pérez, Ricardo; Avendaño-Reyes, Leonel; Mejía-Vázquez, Ángel; Álvarez-Valenzuela, F Daniel; Correa-Calderón, Abelardo; Mellado, Miguel; Meza-Herrera, Cesar A; Guerra-Liera, Juan E; Robinson, P H; Macías-Cruz, Ulises

    2016-01-01

    Rectal temperature (RT) is the foremost physiological variable indicating if an animal is suffering hyperthermia. However, this variable is traditionally measured by invasive methods, which may compromise animal welfare. Models to predict RT have been developed for growing pigs and lactating dairy cows, but not for pregnant heat-stressed ewes. Our aim was to develop a prediction equation for RT using non-invasive physiological variables in pregnant ewes under heat stress. A total of 192 records of respiratory frequency (RF) and hair coat temperature in various body regions (i.e., head, rump, flank, shoulder, and belly) obtained from 24 Katahdin × Pelibuey pregnant multiparous ewes were collected during the last third of gestation (i.e., d 100 to lambing) with a 15 d sampling interval. Hair coat temperatures were taken using infrared thermal imaging technology. Initially, a Pearson correlation analysis examined the relationship among variables, and then multiple linear regression analysis was used to develop the prediction equations. All predictor variables were positively correlated (P<0.01; r=0.59-0.67) with RT. The adjusted equation which best predicted RT (P<0.01; Radj(2)=56.15%; CV=0.65%) included as predictors RF and head and belly temperatures. Comparison of predicted and observed values for RT indicates a suitable agreement (P<0.01) between them with moderate accuracy (Radj(2)=56.15%) when RT was calculated with the adjusted equation. In general, the final equation does not violate any assumption of multiple regression analysis. The RT in heat-stressed pregnant ewes can be predicted with an adequate accuracy using non-invasive physiologic variables, and the final equation was: RT=35.57+0.004 (RF)+0.067 (heat temperature)+0.028 (belly temperature). Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Growth hormone 1 (GH1) gene and performance and post‐race rectal temperature during the South African Ironman triathlon

    PubMed Central

    Walpole, B; Noakes, T D; Collins, M

    2006-01-01

    Background Some studies have suggested that the insertion allele of the ACE gene is associated with endurance performance, including the Ironman triathlon. It is possible that this association is due to genetic linkage between the ACE I/D locus and the T/A variant in intron 4 of the neighbouring GH1 gene. The A variant is associated with lower levels of growth hormone production. Growth hormone has multiple effects, especially on metabolism during exercise and recovery from exercise. Its production during exercise has also been shown to stimulate sweat rate and heat loss. Objective To determine whether the GH1 gene is associated with the performance and/or post‐race rectal temperatures of competitors in the South African Ironman triathlon. Methods A total of 169 of the fastest finishing white male triathletes who completed the 2000 and/or 2001 South African Ironman triathlon and 155 control subjects were genotyped for the T/A variant in the GH1 gene. Post‐race rectal temperature was also determined in 103 of these triathletes. Results There was no significant difference in the frequency of this polymorphism in the GH1 gene when the fastest finishing triathletes were compared with the control subjects. Post‐race rectal temperatures were, however, significantly higher in those triathletes with an AA genotype (mean (SD) 37.7 (0.8)°C) compared with those with a TT genotype (37.2 (0.8)°C) (p  =  0.019). Conclusions The T/A polymorphism in intron 4 of the GH1 gene was not associated with performance of the fastest finishers of the South African Ironman triathlon. Post‐race rectal temperatures were, however, significantly higher in the fastest finishing athletes, who were homozygous for a GH1 genotype associated with lower growth hormone production. PMID:16432002

  4. How hot is too hot? Live-trapped gray wolf rectal temperatures and 1-year survival

    USGS Publications Warehouse

    Barber-Meyer, Shannon M.; Mech, L. David

    2014-01-01

    The ability of physically restrained and anesthetized wolves to thermoregulate is lessened and could lead to reduced survival, yet no information is available about this subject. Therefore, we analyzed rectal temperatures related to survival 1 year post-capture from 173 adult (non-pup) gray wolves (Canis lupus) captured in modified foot-hold traps for radiocollaring during June–August, 1988–2011, in the Superior National Forest of northeastern Minnesota, USA. The maximum observed rectal temperature (“maxtemp,” ° F, ° C) in each wolf during capture (x = 104.0, 40.0; SD = 2.0, 1.1; min. = 95.9, 35.5; max. = 108, 42.2) was not a significant predictor of survival to 1 year post-capture. Although no weather or morphometric variable was a significant predictor of maxtemps, wolves initially anesthetized with ketamine–xylazine rather than telazol®–xylazine averaged higher maxtemps. This information does not fully address possible effects of high body temperatures related to live-capture and handling of wolves, but it does provide a useful waypoint for future assessments of this relationship and a reassurance to wildlife practitioners that the maxtemps observed in our study did not appear to affect 1-year survival.

  5. Effects of L-glutamine on rectal temperature and some markers of oxidative stress in Red Sokoto goats during the hot-dry season.

    PubMed

    Ocheja, Ohiemi Benjamin; Ayo, Joseph Olusegun; Aluwong, Tagang; Minka, Ndazo Salka

    2017-08-01

    The experiment investigated the ameliorative effects of L-glutamine administration on rectal temperature (RT), erythrocyte osmotic fragility (EOF), serum antioxidant enzyme activities and malondialdehyde (MDA) concentration in Red Sokoto goats during the hot-dry season. Twenty eight healthy Red Sokoto goats, comprising 14 experimental (administered 0.2 g/kg of L-glutamine dissolved in 10 mL of distilled water, once daily for 21 days) and 14 control (administered equivalent of distilled water) goats served as subjects. Rectal temperature (measured at 6:00, 13:00 and 18:00 h) and blood samples (taken at 8:00 h) were obtained from all subjects weekly, before, during and after L-glutamine administration. Data obtained were compared using one-way repeated-measures ANOVA, followed by Tukey's post-hoc test. The dry-bulb temperature, relative humidity and temperature-humidity index for the study period ranged between 24.0 and 37.5 °C, 26.0 and 84.0% and 73.0 and 86.3, respectively. L-glutamine administration decreased (P < 0.05) RT, EOF and MDA and increased superoxide dismutase (SOD) activity in experimental group, compared to controls during weeks 1, 2 and 3. Glutathione peroxidase (GPx) and catalase activities were higher (P < 0.05) in the experimental group than in the controls only during week 1 of L-glutamine administration. In conclusion, L-glutamine administration mitigated increases in RT, EOF and serum MDA concentration and enhanced serum SOD, GPx and catalase activities and may be beneficial in heat-stressed goats during the hot-dry season.

  6. Body temperature as a conditional response measure for pavlovian fear conditioning.

    PubMed

    Godsil, B P; Quinn, J J; Fanselow, M S

    2000-01-01

    On six days rats were exposed to each of two contexts. They received an electric shock in one context and nothing in the other. Rats were tested later in each environment without shock. The rats froze and defecated more often in the shock-paired environment; they also exhibited a significantly larger elevation in rectal temperature in that environment. The rats discriminated between each context, and we suggest that the elevation in temperature is the consequence of associative learning. Thus, body temperature can be used as a conditional response measure in Pavlovian fear conditioning experiments that use footshock as the unconditional stimulus.

  7. Rectal compliance as a routine measurement: extreme volumes have direct clinical impact and normal volumes exclude rectum as a problem.

    PubMed

    Felt-Bersma, R J; Sloots, C E; Poen, A C; Cuesta, M A; Meuwissen, S G

    2000-12-01

    The clinical impact of rectal compliance and sensitivity measurement is not clear. The aim of this study was to measure the rectal compliance in different patient groups compared with controls and to establish the clinical effect of rectal compliance. Anorectal function tests were performed in 974 consecutive patients (284 men). Normal values were obtained from 24 controls. Rectal compliance measurement was performed by filling a latex rectal balloon with water at a rate of 60 ml per minute. Volume and intraballoon pressure were measured. Volume and pressure at three sensitivity thresholds were recorded for analysis: first sensation, urge, and maximal toleration. At maximal toleration, the rectal compliance (volume/pressure) was calculated. Proctoscopy, anal manometry, anal mucosal sensitivity, and anal endosonography were also performed as part of our anorectal function tests. No effect of age or gender was observed in either controls or patients. Patients with fecal incontinence had a higher volume at first sensation and a higher pressure at maximal toleration (P = 0.03), the presence of a sphincter defect or low or normal anal pressures made no difference. Patients with constipation had a larger volume at first sensation and urge (P < 0.0001 and P < 0.01). Patients with a rectocele had a larger volume at first sensation (P = 0.004). Patients with rectal prolapse did not differ from controls; after rectopexy, rectal compliance decreased (P < 0.0003). Patients with inflammatory bowel disease had a lower rectal compliance, most pronounced in active proctitis (P = 0.003). Patients with ileoanal pouches also had a lower compliance (P < 0.0001). In the 17 patients where a maximal toleration volume < 60 ml was found, 11 had complaints of fecal incontinence, and 6 had a stoma. In 31 patients a maximal toleration volume between 60 and 100 ml was found; 12 patients had complaints of fecal incontinence, and 6 had a stoma. Proctitis or pouchitis was the main cause for a

  8. [Infrared temperature measurement in the ear canal with the DIATEK 9000 Instatemp and the DIATEK 9000 Thermoguide. Comparison with methods of temperature measurement in other body parts].

    PubMed

    Fritz, U; Rohrberg, M; Lange, C; Weyland, W; Bräuer, A; Braun, U

    1996-11-01

    Temperature of the tympanic membrane is recommended as a "gold standard" of core-temperature recording. However, use of temperature probes in the auditory canal may lead to damage of tympanic membrane. Temperature measurement in the auditory canal with infrared thermometry does not pose this risk. Furthermore it is easy to perform and not very time-consuming. For this reason infrared thermometry of the auditory canal is becoming increasingly popular in clinical practice. We evaluated two infrared thermometers-the Diatek 9000 Thermoguide and the Diatek 9000 Instatemp-regarding factors influencing agreement with conventional tympanic temperature measurement and other core-temperature recording sites. In addition, we systematically evaluated user dependent factors that influence the agreement with the tympanic temperature. In 20 volunteers we evaluated the influence of three factors: duration of the devices in the auditory canal before taking temperature (0 or 5 s), interval between two following recordings (30, 60, 90, 120, 180 s) and positioning of the grip relative to the auditory-canal axis (0, 60, 180 and 270 degrees). Agreement with tympanic contact probes (Mon-a-therm tympanic) in the contralateral ear was investigated in 100 postoperative patients. Comparative readings with rectal (YSI series 400) and esophageal (Mon-a-therm esophageal stethoscope with temperature sensor) probes were done in 100 patients in the ICU. The method of Bland and Altman was taken for comparison. Shortening of the interval between two consecutive readings led to increasing differences between the two measurements with the second reading decreasing. A similar effect was seen when positioning the infrared thermometers in the auditory canal before taking temperatures: after 5 s the recorded temperatures were significantly lower than temperature recordings taken immediately. Rotation of the devices out of the telephone handle position led to increasing lack of agreement between infrared

  9. Changes in concentrations of lysergol in urine and prolactin in plasma, rectal temperature and respiration rate in sheep selected for resistance or susceptibility to ryegrass staggers and fed ergovaline.

    PubMed

    Gooneratne, S R; Scannell, M; Wellby, M; Fletcher, L

    2011-09-01

    To determine the effects of feeding ryegrass seed containing ergovaline to sheep selected for resistance or susceptibility to ryegrass staggers on concentration of lysergol (a metabolite of ergovaline) in urine, prolactin in plasma, rectal temperature and respiration rate. Two experiments were carried out using 12 Romney crossbred ewe lambs aged 9 months, comprising animals resistant (n=4), susceptible (n=4) or outcross (n=4) to ryegrass staggers. In Experiment 1, sheep were given either a single (Part A) or six (Part B) feed (s) of endophyte-infected seed containing ergovaline at 30 mg/kg dry matter (DM), at 42 μg ergovaline/kg bodyweight (BW), to simulate acute and chronic exposure to ergovaline, respectively. The concentration and excretion of lysergol in urine and concentration of prolactin in plasma were measured over 3 and 12 days, for Parts A and B respectively. In Experiment 2, after a recovery period of 7 days, the same sheep were fed with ergovaline at 67 μg/kg of BW for 7 days. Soon after the seventh feed the sheep were moved to a hothouse at 36.5°C and 60% humidity, and 3 h later their rectal temperatures and respiration rates were measured. The concentration of lysergol and excretion in urine increased to a peak between 6 and 9 h after exposure to ergovaline whereas the concentration of prolactin in plasma was markedly reduced. Differences in concentration and rate of excretion of lysergol in urine between animals resistant, outcross and susceptible to ryegrass staggers were not significant (p>0.1). The animals resistant to ryegrass staggers had a lower rectal temperature (p<0.05) and a faster respiration rate than the outcross and susceptible groups when exposed to high ambient temperature and high humidity. This study showed that excretion of lysergol in urine increased with each exposure of sheep to ergovaline. Animals genetically resistant to ryegrass staggers exhibited a lower rectal temperature and a faster respiration rate than those

  10. Oral administration of D-aspartate, but not L-aspartate, depresses rectal temperature and alters plasma metabolites in chicks.

    PubMed

    Erwan, Edi; Chowdhury, Vishwajit Sur; Nagasawa, Mao; Goda, Ryosei; Otsuka, Tsuyoshi; Yasuo, Shinobu; Furuse, Mitsuhiro

    2014-07-25

    L-Aspartate (L-Asp) and D-aspartate (D-Asp) are physiologically important amino acids in mammals and birds. However, the functions of these amino acids have not yet been fully understood. In this study, we therefore examined the effects of L-Asp and D-Asp in terms of regulating body temperature, plasma metabolites and catecholamines in chicks. Chicks were first orally administered with different doses (0, 3.75, 7.5 and 15 mmol/kg body weight) of L- or D-Asp to monitor the effects of these amino acids on rectal temperature during 120 min of the experimental period. Oral administration of D-Asp, but not of L-Asp, linearly decreased the rectal temperature in chicks. Importantly, orally administered D-Asp led to a significant reduction in body temperature in chicks even under high ambient temperature (HT) conditions. However, centrally administered D-Asp did not significantly influence the body temperature in chicks. As for plasma metabolites and catecholamines, orally administered D-Asp led to decreased triacylglycerol and uric acid concentrations and increased glucose and chlorine concentrations but did not alter plasma catecholamines. These results suggest that oral administration of D-Asp may play a potent role in reducing body temperature under both normal and HT conditions. The alteration of plasma metabolites further indicates that D-Asp may contribute to the regulation of metabolic activity in chicks. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Association between obesity and reduced body temperature in dogs.

    PubMed

    Piccione, G; Giudice, E; Fazio, F; Refinetti, R

    2011-08-01

    Industrialized nations are currently experiencing an obesity epidemic, the causes of which are not fully known. One possible mechanism of enhanced energy efficiency that has received almost no attention is a reduction in the metabolic cost of homeothermy, which could be achieved by a modest lowering of body core temperature. We evaluated the potential of this obesity-inducing mechanism in a canine model of the metabolic syndrome. We compared the rectal temperature of lean dogs and obese dogs by (a) conducting cross-sectional measurements in 287 dogs of many breeds varying greatly in body size, (b) conducting longitudinal measurements in individual dogs over 7-10 years and (c) tracking rectal temperature of lean and obese dogs at 3-h intervals for 48 consecutive hours in the laboratory. We found that larger dogs have lower rectal temperatures than smaller dogs and that, for the same body mass, obese dogs have lower rectal temperatures than lean dogs. The results were consistent in the cross-sectional, longitudinal and around-the-clock measurements. These findings document an association between obesity and reduced body temperature in dogs and support the hypothesis that obesity in this and other species of homeotherms may result from an increase in metabolic efficiency achieved by a regulated lowering of body temperature.

  12. In vivo real-time rectal wall dosimetry for prostate radiotherapy

    PubMed Central

    Hardcastle, Nicholas; Cutajar, Dean L.; Metcalfe, Peter E.; Lerch, Michael L. F.; Perevertaylo, Vladimir L.; Tomé, Wolfgang A.; Rosenfeld, Anatoly B.

    2010-01-01

    Rectal balloons are used in external beam prostate radiotherapy to provide reproducible anatomy and rectal dose reductions. This is an investigation into the combination of a MOSFET radiation detector with a rectal balloon for real time in vivo rectal wall dosimetry. The MOSFET used in the study is a radiation detector that provides a water equivalent depth of measurement of 70μm. Two MOSFETs were combined in a face-to-face orientation. The reproducibility, sensitivity and angular dependence were measured for the dual MOSFET in a 6MV photon beam. The dual MOSFET was combined with a rectal balloon and irradiated with hypothetical prostate treatments in a phantom. The anterior rectal wall dose was measured in real time and compared with the planning system calculated dose. The dual MOSFET showed angular dependence within ± 2.5% in the azimuth and +2.5%/-4% in the polar axes. When compared with an ion chamber measurement in a phantom, the dual MOSFET agreed within 2.5% for a range of radiation path lengths and incident angles. The dual MOSFET had reproducible sensitivity for fraction sizes of 2-10Gy. For the hypothetical prostate treatments the measured anterior rectal wall dose was 2.6% and 3.2% lower than the calculated dose for 3DCRT and IMRT plans. This was expected due to limitations of the dose calculation method used at the balloon cavity interface. A dual MOSFET combined with a commercial rectal balloon was shown to provide reproducible measurements of the anterior rectal wall dose in real time. The measured anterior rectal wall dose agreed with the expected dose from the treatment plan for 3DCRT and IMRT plans. The dual MOSFET could be read out in real time during the irradiation, providing capability for real time dose monitoring of the rectal wall dose during treatment. PMID:20571209

  13. Body Temperature Measurements for Metabolic Phenotyping in Mice.

    PubMed

    Meyer, Carola W; Ootsuka, Youichirou; Romanovsky, Andrej A

    2017-01-01

    Key Points Rectal probing is subject to procedural bias. This method is suitable for first-line phenotyping, provided probe depth and measurement duration are standardized. It is also useful for detecting individuals with out-of-range body temperatures (during hypothermia, torpor).The colonic temperature attained by inserting the probe >2 cm deep is a measure of deep (core) body temperature.IR imaging of the skin is useful for detecting heat leaks and autonomous thermoregulatory alterations, but it does not measure body temperature.Temperature of the hairy or shaved skin covering the inter-scapular brown adipose tissue can be used as a measure of BAT thermogenesis. However, obtaining such measurements of sufficient quality is very difficult, and interpreting them can be tricky. Temperature differences between the inter-scapular and lumbar areas can be a better measure of the thermogenic activity of inter-scapular brown adipose tissue.Implanted probes for precise determination of BAT temperature (changes) should be fixed close to the Sulzer's vein. For measurement of BAT thermogenesis, core body temperature and BAT temperature should be recorded simultaneously.Tail temperature is suitable to compare the presence or absence of vasoconstriction or vasodilation.Continuous, longitudinal monitoring of core body temperature is preferred over single probing, as the readings are taken in a non-invasive, physiological context.Combining core body temperature measurements with metabolic rate measurements yields insights into the interplay between heat production and heat loss (thermal conductance), potentially revealing novel thermoregulatory phenotypes. Endothermic organisms rely on tightly balanced energy budgets to maintain a regulated body temperature and body mass. Metabolic phenotyping of mice, therefore, often includes the recording of body temperature. Thermometry in mice is conducted at various sites, using various devices and measurement practices, ranging from

  14. Reliability of an infrared forehead skin thermometer for core temperature measurements.

    PubMed

    Kistemaker, J A; Den Hartog, E A; Daanen, H A M

    2006-01-01

    The SensorTouch thermometer performs an infrared measurement of the skin temperature above the Superficial Temporal Artery (STA). This study evaluates the validity and the accuracy of the SensorTouch thermometer. Two experiments were performed in which the body temperature was measured with a rectal sensor, with an oesophageal sensor and with the SensorTouch. After entering a warm chamber the SensorTouch underestimated the core temperature during the first 10 minutes. After that, the SensorTouch was not significantly different from the core temperature, with an average difference of 0.5 degrees C (SD 0.5 degrees C) in the first study and 0.3 degrees C (SD 0.2 degrees C) in the second study. The largest differences between the SensorTouch and the core temperature existed 15 minutes after the start of the exercise. During this period the SensorTouch was significantly higher than the core temperature. The SensorTouch did not provide reliable values of the body temperature during periods of increasing body temperature, but the SensorTouch might work under stable conditions.

  15. Rectal biopsy

    MedlinePlus

    ... biopsy; Amyloidosis - rectal biopsy; Crohn disease - rectal biopsy; Colorectal cancer - biopsy; Hirschsprung disease - rectal biopsy ... abnormal conditions of the rectum, such as: Abscesses Colorectal ... Inflammation Tumors Amyloidosis Crohn disease Hirschsprung ...

  16. Age-related changes of serum mitochondrial uncoupling 1, rumen and rectal temperature in goats.

    PubMed

    Arfuso, Francesca; Rizzo, Maria; Giannetto, Claudia; Giudice, Elisabetta; Fazio, Francesco; Piccione, Giuseppe

    2016-07-01

    Thermoregulatory processes are induced not only by exposure to cold or heat but also by a variety of physiological situations including age, fasting and food intake that result in changes in body temperature. The aim of the present study was to evaluate the differences in serum mitochondrial uncoupling protein 1 (UCP1), rumen temperature (TRUMEN) and rectal temperature (TRECTAL) values between adult and kids goats. Ten adult male Maltese goats aged 3-5 years old (Group A) and 30 male kids, raised for meat, were enrolled in this study. The kids were equally divided into 3 groups according to their age: Group B included kids aged 3 months, Group C included kids aged 4 months and Group D included kids aged 5 months. Blood samples and measurements of TRUMEN and TRECTAL were obtained from each animal. One-way repeated measures analysis of variance (ANOVA) was applied to evaluate the effect of age on the studied parameters. Statistically significant higher serum UCP1 levels (P<0.001) were found in Group A as compared to Groups B, C and D. Higher TRUMEN values (P<0.001) were found in Group A than in Groups B, C and D, and in Group B than in Groups C and D. Group A showed lower TRECTAL values (P<0.001) than Groups B, C and D. The Pearson's Correlation test was applied to assess significant relationship among studied parameters showing a statistically significant negative correlation between the values of TRECTAL and serum UCP1 in all studied Groups (P<0.001). These results indicate that goats have good control of body temperature suggesting that further details about the thermogenic capacity and the function of UCP1 in kids and adult goats are worth exploring. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Comparison of Gastrointestinal and Rectal Temperatures During Recovery After a Warm-Weather Road Race.

    PubMed

    Hosokawa, Yuri; Adams, William M; Stearns, Rebecca L; Casa, Douglas J

    2016-05-01

    It has been well established that gastrointestinal temperature (TGI) tracks closely with rectal temperature (TREC) during exercise. However, the field use of TGI pills is still being examined, and little is known about how measurements obtained using these devices compare during recovery after exercise in warm weather. To compare TGI and TREC in runners who completed an 11.3-km warm-weather road race and determine if runners with higher TGI and TREC present with greater passive cooling rates during recovery. Cross-sectional study. Field. Thirty recreationally active runners (15 men, 15 women; age = 39 ± 11 years, weight = 68.3 ± 11.7 kg, body fat = 19.2% ± 5.0%). The TGI and TREC were obtained immediately after the race and during a 20-minute passive rest at the 2014 Falmouth Road Race (heat index = 26.2°C ± 0.9°C). Temperatures were taken every 2 minutes during passive rest. The main dependent variables were mean bias and limits of agreement for TGI and TREC, using Bland-Altman analysis, and the 20-minute passive cooling rates for TGI and TREC. No differences were evident between TGI and TREC throughout passive rest (P = .542). The passive cooling rates for TGI and TREC were 0.046 ± 0.031°C·min(-1) and 0.060 ± 0.036°C·min(-1), respectively. Runners with higher TGI and TREC at the start of cooling had higher cooling rates (R = 0.682, P < .001 and R = 0.54, P = .001, respectively). The mean bias of TGI during the 20-minute passive rest was -0.06°C ± 0.56°C with 95% limits of agreement of ±1.09°C. After participants completed a warm-weather road race, TGI provided a valid measure of body temperature compared with the criterion measure of TREC. Therefore, TGI may be a viable option for monitoring postexercise-induced hyperthermia, if the pill is administered prophylactically.

  18. Comparison of antipyretic effectiveness of equal doses of rectal and oral acetaminophen in children.

    PubMed

    Karbasi, Sedigha Akhavan; Modares-Mosadegh, Moneyreh; Golestan, Motahhareh

    2010-01-01

    To compare a dose of oral and rectal acetaminophen and to evaluate acceptability of rectal acetaminophen, since oral and rectal acetaminophen is widely used as an antipyretic agent in febrile children and the comparative effectiveness of these two preparations is not well established. In this prospective parallel group designed study, 60 children who presented to the emergency department or outpatient pediatric clinic at a tertiary hospital and aged from 6 months to 6 years with rectal temperature over 39 degrees C were enrolled. Patients were randomly assigned to two equal-sized groups. Group 1 received 15 mg/kg acetaminophen rectally and group 2 received the same dose orally. Temperature was recorded at baseline and 1 and 3 hours after drug administration. In the first group, mean decrease in temperature, 1 and 3 hours after administration of acetaminophen was 1.07+/-0.16 (p < 0.001) and 1.74+/-0.25 degrees C (p < 0.001), respectively, and in the second group it was 1.98+/-0.19 (p < 0.001) and 1.70+/-0.14 degrees C (p < 0.001), respectively (p > 0.05). Rectal and oral acetaminophen preparations have equal antipyretic effectiveness in children. The rectal route proved to be as acceptable as the oral one among parents.

  19. Comparison of Gastrointestinal and Rectal Temperatures During Recovery After a Warm-Weather Road Race

    PubMed Central

    Hosokawa, Yuri; Adams, William M.; Stearns, Rebecca L.; Casa, Douglas J.

    2016-01-01

    Context:  It has been well established that gastrointestinal temperature (TGI) tracks closely with rectal temperature (TREC) during exercise. However, the field use of TGI pills is still being examined, and little is known about how measurements obtained using these devices compare during recovery after exercise in warm weather. Objective:  To compare TGI and TREC in runners who completed an 11.3-km warm-weather road race and determine if runners with higher TGI and TREC present with greater passive cooling rates during recovery. Design:  Cross-sectional study. Setting:  Field. Patients or Other Participants:  Thirty recreationally active runners (15 men, 15 women; age = 39 ± 11 years, weight = 68.3 ± 11.7 kg, body fat = 19.2% ± 5.0%). Main Outcome Measure(s):  The TGI and TREC were obtained immediately after the race and during a 20-minute passive rest at the 2014 Falmouth Road Race (heat index = 26.2°C ± 0.9°C). Temperatures were taken every 2 minutes during passive rest. The main dependent variables were mean bias and limits of agreement for TGI and TREC, using Bland-Altman analysis, and the 20-minute passive cooling rates for TGI and TREC. Results:  No differences were evident between TGI and TREC throughout passive rest (P = .542). The passive cooling rates for TGI and TREC were 0.046 ± 0.031°C·min−1 and 0.060 ± 0.036°C·min−1, respectively. Runners with higher TGI and TREC at the start of cooling had higher cooling rates (R = 0.682, P < .001 and R = 0.54, P = .001, respectively). The mean bias of TGI during the 20-minute passive rest was −0.06°C ± 0.56°C with 95% limits of agreement of ±1.09°C. Conclusions:  After participants completed a warm-weather road race, TGI provided a valid measure of body temperature compared with the criterion measure of TREC. Therefore, TGI may be a viable option for monitoring postexercise-induced hyperthermia, if the pill is administered prophylactically. PMID:27186918

  20. Prediction of human core body temperature using non-invasive measurement methods.

    PubMed

    Niedermann, Reto; Wyss, Eva; Annaheim, Simon; Psikuta, Agnes; Davey, Sarah; Rossi, René Michel

    2014-01-01

    The measurement of core body temperature is an efficient method for monitoring heat stress amongst workers in hot conditions. However, invasive measurement of core body temperature (e.g. rectal, intestinal, oesophageal temperature) is impractical for such applications. Therefore, the aim of this study was to define relevant non-invasive measures to predict core body temperature under various conditions. We conducted two human subject studies with different experimental protocols, different environmental temperatures (10 °C, 30 °C) and different subjects. In both studies the same non-invasive measurement methods (skin temperature, skin heat flux, heart rate) were applied. A principle component analysis was conducted to extract independent factors, which were then used in a linear regression model. We identified six parameters (three skin temperatures, two skin heat fluxes and heart rate), which were included for the calculation of two factors. The predictive value of these factors for core body temperature was evaluated by a multiple regression analysis. The calculated root mean square deviation (rmsd) was in the range from 0.28 °C to 0.34 °C for all environmental conditions. These errors are similar to previous models using non-invasive measures to predict core body temperature. The results from this study illustrate that multiple physiological parameters (e.g. skin temperature and skin heat fluxes) are needed to predict core body temperature. In addition, the physiological measurements chosen in this study and the algorithm defined in this work are potentially applicable as real-time core body temperature monitoring to assess health risk in broad range of working conditions.

  1. Stapled haemorrhoidopexy transiently decreases rectal compliance and sensitivity.

    PubMed

    Filho, F L A; Macedo, G M; Dos Santos, A A; Rodrigues, L V; Oliveira, R B; Nobre E Souza, M A

    2011-02-01

    Stapled haemorrhoidopexy may damage the anorectal musculature and its sensorimotor function. Most studies have not used a barostat for the measurement of compliance. This study aimed to investigate the effect of stapled haemorrhoidopexy on rectal compliance and sensitivity. After Ethical Committee approval, we studied 10 male patients (mean age 33.8 years) with third- or fourth-degree haemorrhoids. Rectal compliance and sensitivity were measured with a 600-ml bag and an electronic barostat. Volunteers were submitted to two consecutive rectal distension protocols, including continuous distension at 2, 4 and 6 months after stapled haemorrhoidopexy. Intraluminal volume and pressure were recorded, including the first rectal sensation, desire to defecate and onset of rectal pain. Another group of 10 male control patients (mean age 24.9 years) with pilonidal sinus and no haemorrhoids was also included in the study. Two months after stapled haemorrhoidopexy, rectal compliance decreased (7.1 ± 0.2 vs 5.3 ± 0.1, 6.4 ± 0.1 vs 5.1 ± 0.1 and 5.6 ± 0.2 vs 4.7 ± 0.1 ml/mmHg for first rectal sensation, desire to defecate and rectal pain, respectively; P < 0.05). The sensitivity threshold volume did not change for the first sensation but decreased significantly for the desier to defecate and pain (p <0.05) (116.8 ± 13.8 vs 148.4 ± 14.61, 251.1 ± 8.9 vs 185.8 ± 8.6 and 293.3 ± 16.6 vs 221.2 ± 6.0 ml for first rectal sensation, desire to defecate and rectal pain, respectively). Four and 6 months after surgery, rectal compliance and sensitivity returned to levels similar to those in the basal period. Muscle tissue was found in only three of the 10 resected doughnuts. Controls remained without any change in rectal compliance and sensitivity. Stapled haemorrhoidopexy transiently decreases rectal compliance and sensitivity threshold in young male patients. © 2010 The Authors. Colorectal Disease © 2010 The Association of Coloproctology of Great Britain and Ireland.

  2. Estimating core temperature in infants and children after cardiac surgery: a comparison of six methods.

    PubMed

    Maxton, Fiona J C; Justin, Linda; Gillies, Donna

    2004-01-01

    Monitoring temperature in critically ill children is an important component of care, yet the accuracy of methods is often questioned. Temperature measured in the pulmonary artery is considered the 'gold standard', but this route is unsuitable for the majority of patients. An accurate, reliable and less invasive method is, however, yet to be established in paediatric intensive care work. To determine which site most closely reflects core temperature in babies and children following cardiac surgery, by comparing pulmonary artery temperature to the temperature measured at rectal, bladder, nasopharyngeal, axillary and tympanic sites. A convenience sample of 19 postoperative cardiac patients was studied. Temperature was recorded as a continuous measurement from pulmonary artery, rectal, nasopharyngeal and bladder sites. Axillary and tympanic temperatures were recorded at 30 minute intervals for 6 1/2 hours postoperatively. The small sample size of 19 infants and children limits the generalizability of the study. Repeated measures analysis of variance demonstrated no significant difference between pulmonary artery and bladder temperatures, and pulmonary artery and nasopharyngeal temperatures. Intraclass correlation showed that agreement was greatest between pulmonary artery temperature and temperature measured by bladder catheter. There was a significant difference between pulmonary artery temperature and temperature measured at rectal, tympanic and pulmonary artery and axillary sites. Repeated measures analysis showed a significant lag between pulmonary artery and rectal temperature of between 0 and 150 minutes after the 6-hour measurement period. In this study, bladder temperature was shown to be the best estimate of pulmonary artery temperature, closely followed by the temperature measured by nasopharyngeal probe. The results support the use of bladder or nasopharyngeal catheters to monitor temperature in critically ill children after cardiac surgery.

  3. Validity and Reliability of Devices That Assess Body Temperature During Indoor Exercise in the Heat

    PubMed Central

    Ganio, Matthew S; Brown, Christopher M; Casa, Douglas J; Becker, Shannon M; Yeargin, Susan W; McDermott, Brendon P; Boots, Lindsay M; Boyd, Paul W; Armstrong, Lawrence E; Maresh, Carl M

    2009-01-01

    Context: When assessing exercise hyperthermia outdoors, the validity of certain commonly used body temperature measuring devices has been questioned. A controlled laboratory environment is generally less influenced by environmental factors (eg, ambient temperature, solar radiation, wind) than an outdoor setting. The validity of these temperature measuring devices in a controlled environment may be more acceptable. Objective: To assess the validity and reliability of commonly used temperature devices compared with rectal temperature in individuals exercising in a controlled, high environmental temperature indoor setting and then resting in a cool environment. Design: Time series study. Setting: Laboratory environmental chamber (temperature  =  36.4 ± 1.2°C [97.5 ± 2.16°F], relative humidity  =  52%) and cool laboratory (temperature  =  approximately 23.3°C [74.0°F], relative humidity  =  40%). Patients or Other Participants: Fifteen males and 10 females. Intervention(s): Rectal, gastrointestinal, forehead, oral, aural, temporal, and axillary temperatures were measured with commonly used temperature devices. Temperature was measured before and 20 minutes after entering the environmental chamber, every 30 minutes during a 90-minute treadmill walk in the heat, and every 20 minutes during a 60-minute rest in mild conditions. Device validity and reliability were assessed with various statistical measures to compare the measurements using each device with rectal temperature. A device was considered invalid if the mean bias (average difference between rectal and device temperatures) was more than ±0.27°C (±0.50°F). Main Outcome Measure(s): Measured temperature from each device (mean and across time). Results: The following devices provided invalid estimates of rectal temperature: forehead sticker (0.29°C [0.52°F]), oral temperature using an inexpensive device (−1.13°C [−2.03°F]), temporal temperature measured according to the instruction

  4. Human thermoregulation and measurement of body temperature in exercise and clinical settings.

    PubMed

    Lim, Chin Leong; Byrne, Chris; Lee, Jason Kw

    2008-04-01

    This review discusses human thermoregulation during exercise and the measurement of body temperature in clinical and exercise settings. The thermoregulatory mechanisms play important roles in maintaining physiological homeostasis during rest and physical exercise. Physical exertion poses a challenge to thermoregulation by causing a substantial increase in metabolic heat production. However, within a non-thermolytic range, the thermoregulatory mechanisms are capable of adapting to sustain physiological functions under these conditions. The central nervous system may also rely on hyperthermia to protect the body from "overheating." Hyperthermia may serve as a self-limiting signal that triggers central inhibition of exercise performance when a temperature threshold is achieved. Exposure to sub-lethal heat stress may also confer tolerance against higher doses of heat stress by inducing the production of heat shock proteins, which protect cells against the thermolytic effects of heat. Advances in body temperature measurement also contribute to research in thermoregulation. Current evidence supports the use of oral temperature measurement in the clinical setting, although it may not be as convenient as tympanic temperature measurement using the infrared temperature scanner. Rectal and oesophagus temperatures are widely accepted surrogate measurements of core temperature (Tc), but they cause discomfort and are less likely to be accepted by users. Gastrointestinal temperature measurement using the ingestible temperature sensor provides an acceptable level of accuracy as a surrogate measure of Tc without causing discomfort to the user. This form of Tc measurement also allows Tc to be measured continuously in the field and has gained wider acceptance in the last decade.

  5. Immunoscore in Rectal Cancer

    ClinicalTrials.gov

    2017-06-13

    Cancer of the Rectum; Neoplasms, Rectal; Rectal Cancer; Rectal Tumors; Rectal Adenocarcinoma; Melanoma; Breast Cancer; Renal Cell Cancer; Lung Cancer; Bladder Cancer; Head and Neck Cancer; Ovarian Cancer; Thyroid Cancer

  6. Evaluation of a telemetric gastrointestinal pill for continuous monitoring of gastrointestinal temperature in horses at rest and during exercise.

    PubMed

    Verdegaal, Elisabeth-Lidwien J M M; Delesalle, Catherine; Caraguel, Charles G B; Folwell, Louise E; McWhorter, Todd J; Howarth, Gordon S; Franklin, Samantha H

    2017-07-01

    OBJECTIVE To evaluate use of a telemetric gastrointestinal (GI) pill to continuously monitor GI temperature in horses at rest and during exercise and to compare time profiles of GI temperature and rectal temperature. ANIMALS 8 Standardbred horses. PROCEDURES Accuracy and precision of the GI pill and a rectal probe were determined in vitro by comparing temperature measurements with values obtained by a certified resistance temperature detector (RTD) in water baths at various temperatures (37°, 39°, and 41°C). Subsequently, both GI and rectal temperature were recorded in vivo in 8 horses over 3 consecutive days. The GI temperature was recorded continuously, and rectal temperature was recorded for 3.5 hours daily. Comparisons were made between GI temperature and rectal temperature for horses at rest, during exercise, and after exercise. RESULTS Water bath evaluation revealed good agreement between the rectal probe and RTD. However, the GI pill systematically underestimated temperature by 0.14°C. In vivo, GI temperature data were captured with minimal difficulties. Most data loss occurred during the first 16 hours, after which the mean ± SD data loss was 8.6 ± 3.7%. The GI temperature was consistently and significantly higher than rectal temperature with an overall mean temperature difference across time of 0.27°C (range, 0.22° to 0.32°C). Mean measurement cessation point for the GI pill was 5.1 ± 1.0 days after administration. CONCLUSIONS AND CLINICAL RELEVANCE This study revealed that the telemetric GI pill was a reliable and practical method for real-time monitoring of GI temperature in horses.

  7. Influence of the Environment on Body Temperature of Racing Greyhounds.

    PubMed

    McNicholl, Jane; Howarth, Gordon S; Hazel, Susan J

    2016-01-01

    Heat strain is a potential risk factor for racing greyhounds in hot climates. However, there have been limited studies into the incidence of heat strain (when excess heat causes physiological or pathological effects) in racing greyhounds. The aim of this study was to determine if heat strain occurs in racing greyhounds, and, if so, whether environmental factors (e.g., ambient temperature and relative humidity) or dog-related factors (e.g., sex, bodyweight, color) are associated with the risk of heat strain. A total of 229 greyhounds were included in over 46 race meetings and seven different race venues in South Australia, Australia. Rectal temperatures of dogs were measured pre- and postrace and urine samples collected for analysis of myoglobinuria. Ambient temperature at race times ranged between 11.0 and 40.8°C and relative humidity ranged from 17 to 92%. There was a mean increase in greyhound rectal temperature of 2.1°C (range 1.1-3.1°C). A small but significant association was present between ambient temperature and increase in rectal temperature (r (2) = 0.033, P = 0.007). The mean ambient temperature at race time, of dogs with postrace rectal temperature of or exceeding 41.5°C, was significantly greater than at race time of dogs with a postrace rectal temperature ≤41.5°C (31.2 vs. 27.3°C, respectively, P = 0.004). When the ambient temperature reached 38(o)C, over one-third (39%) of dogs had a rectal temperature >41.5°C. Over half of postrace urine samples were positive by Dipstick reading for hemoglobin/myoglobin, and of 77 urine samples positive for Dipstick readings, 95% were positive for myoglobin. However, urinary myoglobin levels were not associated with ambient temperature or postrace rectal temperatures. The mean increase in rectal temperature was greater in dark (black, blue, brindle) than light (fawn and white) colored greyhounds. The results suggest heat strain occurs in racing greyhounds, evidenced by postrace rectal

  8. Influence of the Environment on Body Temperature of Racing Greyhounds

    PubMed Central

    McNicholl, Jane; Howarth, Gordon S.; Hazel, Susan J.

    2016-01-01

    Heat strain is a potential risk factor for racing greyhounds in hot climates. However, there have been limited studies into the incidence of heat strain (when excess heat causes physiological or pathological effects) in racing greyhounds. The aim of this study was to determine if heat strain occurs in racing greyhounds, and, if so, whether environmental factors (e.g., ambient temperature and relative humidity) or dog-related factors (e.g., sex, bodyweight, color) are associated with the risk of heat strain. A total of 229 greyhounds were included in over 46 race meetings and seven different race venues in South Australia, Australia. Rectal temperatures of dogs were measured pre- and postrace and urine samples collected for analysis of myoglobinuria. Ambient temperature at race times ranged between 11.0 and 40.8°C and relative humidity ranged from 17 to 92%. There was a mean increase in greyhound rectal temperature of 2.1°C (range 1.1–3.1°C). A small but significant association was present between ambient temperature and increase in rectal temperature (r2 = 0.033, P = 0.007). The mean ambient temperature at race time, of dogs with postrace rectal temperature of or exceeding 41.5°C, was significantly greater than at race time of dogs with a postrace rectal temperature ≤41.5°C (31.2 vs. 27.3°C, respectively, P = 0.004). When the ambient temperature reached 38oC, over one-third (39%) of dogs had a rectal temperature >41.5°C. Over half of postrace urine samples were positive by Dipstick reading for hemoglobin/myoglobin, and of 77 urine samples positive for Dipstick readings, 95% were positive for myoglobin. However, urinary myoglobin levels were not associated with ambient temperature or postrace rectal temperatures. The mean increase in rectal temperature was greater in dark (black, blue, brindle) than light (fawn and white) colored greyhounds. The results suggest heat strain occurs in racing greyhounds, evidenced by postrace rectal temperatures

  9. Confounding factors in the use of the zero-heat-flow method for non-invasive muscle temperature measurement.

    PubMed

    Brajkovic, Dragan; Ducharme, Michel B

    2005-07-01

    This study evaluated a zero-heat-flow (ZHF), non-invasive temperature probe for in- vivo measurement of resting muscle temperature for up to 2 cm below the skin surface. The ZHF probe works by preventing heat loss from the tissue below the probe by actively heating the tissue until no temperature gradient exists across the probe. The skin temperature under the probe is then used as an indicator of the muscle temperature below. Eight subjects sat for 130 min during exposure to 28 degrees C air. Vastus lateralis (lateral thigh) muscle temperature was measured non-invasively using a ZHF probe which covered an invasive multicouple probe (which measured tissue temperature 0.5 cm, 1 cm, 1.5 cm, and 2 cm below the skin) located 15 cm superior to the patella (T (covered)). T (covered) was evaluated against an uncovered control multicouple probe located 20 cm superior to the patella (T (uncovered)). Rectal temperature and lateral thigh skin temperature were also measured. Mean T (uncovered) (based on average temperatures at the 0.5 cm, 1 cm, 1.5 cm, and 2 cm depths) and Mean T (covered) were similar from time 0 min to 60 min. However, when the ZHF was turned on at 70 min, Mean T (covered) increased by 2.11 +/- 0.20 degrees C by 130 min, while T (uncovered) remained stable. The ZHF probe temperature was similar to T (covered) at 1 cm and after time 85 min, significantly higher than T (covered) at the 0.5 cm, 1.5 cm, and 2 cm depths; however from a physiological standpoint, the temperatures between the different depths and the ZHF probe could be considered uniform (< or =0.2 degrees C separation). Rectal and thigh skin temperatures were stable at 36.99 +/- 0.08 degrees C and 32.82 +/- 0.23 degrees C, respectively. In conclusion, the non-invasive ZHF probe temperature was similar to the T (covered) temperatures directly measured up to 2 cm beneath the surface of the thigh, but all T (covered) temperatures were not representative of the true muscle temperature up to 2 cm below

  10. First practical applications of eye temperature measurements for estimation of the time of death in casework. Report of three cases.

    PubMed

    Kaliszan, Michał

    2012-06-10

    This paper presents first three successive cases of death where at scene measurements of the internal eyeball temperature soon after death allowed to precisely estimate the times of deaths based on this data (33.1°C, 32.2°C and 29.5°C, respectively), which were later confirmed during the police investigation. Simultaneously the rectal temperatures in all three cases were measured and appeared to be between 36.3 and 36.8°C-reflecting a living individual's body temperature. Thanks to a significantly faster postmortem decrease of the eye temperature and a residual or nonexistent plateau effect affecting the eye, using the formula developed in previous comprehensive studies in pigs, the time of death in real cases could be estimated with good precision: 1 h 33 min, 2 h 24 min and 3 h 17 min since death respectively. The actual TOD established during investigation appeared to be: between 1 h 30 min and 1 h 50 min in case 1; 1 h 55 min in case 2 and between 2 h 55 min and 3 h 05 min in case 3. Such precise estimation, mainly due to the plateau effect lasting up to a few hours, could not have been done based only on rectal temperature, commonly measured in forensic practice. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  11. Effects of gastrointestinal parasites on parasite burden, rectal temperature, and antibody titer responses to vaccination and infectious bovine rhinotracheitis virus challenge.

    PubMed

    Schutz, J S; Carroll, J A; Gasbarre, L C; Shelton, T A; Nordstrom, S T; Hutcheson, J P; Van Campen, H; Engle, T E

    2012-06-01

    Thirty-three colostrum-deprived Holstein bull calves (initial BW of 131 ± 4 kg) were used to determine the effect of timing of anthelmintic administration relative to vaccination on antibody titer response to vaccine component antigens. When calves were at least 3 mo of age, they were sorted randomly into individual pens and assigned to 1 of 3 treatment groups, treatments consisted of 1) dewormed 2 wk before vaccination (DPV), 2) dewormed at the time of vaccination (DV), or 3) control, vaccinated but not dewormed (CONT). All calves were inoculated with infective larvae of brown stomach worms (Ostertagia ostertagi) and intestinal worms (Cooperia spp.) on d 1, 7, 10, 14, and 18 for a total dose of 235,710 infective larvae per calf. Calves (DPV and DV) were dewormed on d 21 or 35 with a 10% fenbendazole suspension at 5 mg/kg of BW. On d 35, all calves were vaccinated with a modified-live virus respiratory vaccine containing IBRV (infectious bovine rhinotracheitis virus), BVDV-1 (bovine viral diarrhea virus genotype 1), BVDV-2 (BVDV genotype 2), PI-3 (parainfluenza-3), and BRSV (bovine respiratory syncytial virus). During the 103-d experiment, weekly fecal egg counts, blood, and rectal temperatures were collected and health status was recorded daily. Blood samples were obtained weekly to determine serum neutralizing (SN) antibody titers to IBRV, BVDV-1, BVDV-2, and PI-3 and cytokine levels for IL-4, IL-6, TNF-α (tumor necrosis factor-α), and IFN-γ (interferon-gamma). There was a tendency (P < 0.09) for CONT calves to have greater IL-4 concentrations. By design, control calves had greater (P < 0.01) fecal egg counts during the experiment. All calves developed antibody titers to IBRV, BVDV-1, BVDV-2, and PI-3 by d 15 postvaccination. On d 88, all calves were challenged with IBRV and blood samples were obtained on d 88, 89, 90, 93, 95, 98, 99, and 103. All calves had increased rectal temperatures during the final 7 d of the IBRV challenge. However, the CONT group had

  12. Validity of Devices That Assess Body Temperature During Outdoor Exercise in the Heat

    PubMed Central

    Casa, Douglas J; Becker, Shannon M; Ganio, Matthew S; Brown, Christopher M; Yeargin, Susan W; Roti, Melissa W; Siegler, Jason; Blowers, Julie A; Glaviano, Neal R; Huggins, Robert A; Armstrong, Lawrence E; Maresh, Carl M

    2007-01-01

    Context: Rectal temperature is recommended by the National Athletic Trainers' Association as the criterion standard for recognizing exertional heat stroke, but other body sites commonly are used to measure temperature. Few authors have assessed the validity of the thermometers that measure body temperature at these sites in athletic settings. Objective: To assess the validity of commonly used temperature devices at various body sites during outdoor exercise in the heat. Design: Observational field study. Setting: Outdoor athletic facilities. Patients or Other Participants: Fifteen men and 10 women (age = 26.5 ± 5.3 years, height = 174.3 ± 11.1 cm, mass = 72.73 ± 15.95 kg, body fat = 16.2 ± 5.5%). Intervention(s): We simultaneously tested inexpensive and expensive devices orally and in the axillary region, along with measures of aural, gastrointestinal, forehead, temporal, and rectal temperatures. Temporal temperature was measured according to the instruction manual and a modified method observed in medical tents at local road races. We also measured forehead temperatures directly on the athletic field (other measures occurred in a covered pavilion) where solar radiation was greater. Rectal temperature was the criterion standard used to assess the validity of all other devices. Subjects' temperatures were measured before exercise, every 60 minutes during 180 minutes of exercise, and every 20 minutes for 60 minutes of postexercise recovery. Temperature devices were considered invalid if the mean bias (average difference between rectal temperature and device temperature) was greater than ±0.27°C (±0.5°F). Main Outcome Measure(s): Temperature from each device at each site and time point. Results: Mean bias for the following temperatures was greater than the allowed limit of ±0.27°C (±0.5°F): temperature obtained via expensive oral device (−1.20°C [−2.17°F]), inexpensive oral device (−1.67°C [−3.00°F]), expensive axillary device (−2.58°C [−4

  13. Hydrocortisone Rectal

    MedlinePlus

    Rectal hydrocortisone is used along with other medications to treat proctitis (swelling in the rectum) and ulcerative colitis (a ... and swelling from hemorrhoids and other rectal problems. Hydrocortisone is in a class of medications called corticosteroids. ...

  14. Rectal Cancer Survivors’ Participation in Productive Activities

    PubMed Central

    Hornbrook, Mark C; Grant, Marcia; Wendel, Christopher; Bulkley, Joanna E; McMullen, Carmit K; Altschuler, Andrea; Temple, Larissa KF; Herrinton, Lisa J; Krouse, Robert S

    2018-01-01

    Context Rectal cancer and its treatment impair survivors’ productivity. Objective To assess determinants of market and nonmarket employment, job search, volunteering, and homemaking among survivors five years or longer after diagnosis. Design We mailed questionnaires to 1063 survivors who were members of Kaiser Permanente (Northern California, Northwest) during 2010 and 2011. Main Outcome Measures Productive activities, functional health status, and bowel management at the time of the survey. Results Response rate was 60.5% (577/953). Higher comorbidity burdens were associated with lower productivity for men and women rectal cancer survivors. Productive survivors were younger and had lower disease stage and age at diagnosis, higher household income and educational attainment, and fewer comorbidity burdens and workplace adjustments than did nonproductive survivors (p < 0.05 each; 2-sided). Productive rectal cancer survivors were evenly split by sex. Conclusion Staying productive is associated with better mental health for rectal cancer survivors. Rectal cancer survivors with multiple chronic conditions, higher disease stage, lower productive activities, and older age need better access to medical care and closer monitoring of the quality of their care, including self-care. To capture the full extent of the involvement of survivors in all types of productive activities, research should routinely include measures of employment, searching for employment, homemaking, and volunteering. Counting market and nonmarket productive activities is innovative and recognizes the continuum of contributions survivors make to families and society. Health care systems should routinely monitor rectal cancer survivors’ medical care access, comorbidities, health-related quality of life, and productive activities. PMID:29236653

  15. Rectal cooling test in the differentiation between constipation due to rectal inertia and anismus.

    PubMed

    Shafik, A; Shafik, I; El Sibai, O; Shafik, A A

    2007-03-01

    The differentiation between constipation due to rectal inertia and that due to outlet obstruction from non-relaxing puborectalis muscle (PRM) is problematic and not easily achieved with one diagnostic test. Therefore, we studied the hypothesis that the rectal cooling test (RCT) can effectively be used to differentiate between those two forms of constipation. The study enrolled 28 patients with constipation and abnormal transit study in whom radio-opaque markers accumulated in the rectum; 15 healthy volunteers acted as controls. Electromyographic activity of the external anal sphincter (EAS) and PRM was initially recorded. Subsequently rectal wall tone was assessed by a barostat system during rectal infusion with normal saline at 30 degrees C and at 4 degrees C with simultaneous electromyography (EMG). There was a significant increase in EMG activity of the EAS and PRM on strain- ing (p<0.001), suggestive of anismus, in 10 of 28 patients and 0 of 15 controls. Rectal tone in controls did not respond to saline infusion at 30 degrees C, but it increased at 4 degrees C (p<0.05). Similarly, in constipated patients rectal tone did not respond to rectal saline infusion at 30 degrees C, but infusion at 4 degrees C increased tone in all 10 patients with anismus (p<0.05); EMG activity of the EAS and PRM also increased (p<0.001). In the remaining 18 patients, rectal tone after saline infusion at 4 degrees C remained unchanged. Rectal infusion with iced saline increased rectal tone in healthy controls and constipated patients with anismus while it had no effect in the remaining patients. Lack of increase of rectal tone may be secondary to rectal inertia. According to these preliminary observations, the rectal cooling test may be useful in differentiating between rectal inertia and anismus.

  16. Temperature responses to infusion of electrolytes during exercise

    NASA Technical Reports Server (NTRS)

    Greenleaf, J. E.; Kozlowski, S.; Kaciuba-Uscilko, H.; Nazar, K.; Brzezinska, Z.

    1975-01-01

    To gain more insight into the ion-osmotic influence on temperature regulation, the rectal temperature responses of mongrel dogs were measured during one hour of treadmill-running at 1.2 m/sec up a 12 deg slope. Results indicate that as in man, the rise in body temperature during exercise appears to be a regulated process. There is a direct relationship between the rise and equilibrium levels of rectal temperature and the plasma sodium and osmotic concentrations. It remains to be determined if the hypernatremic-osmolality inhibits peripheral blood flow, the panting, salivation response, or both. Some background on previous experiments on resting and exercising dogs and men is recounted.

  17. Apex technique in the treatment of obstructed defecation syndrome associated with rectal intussusception and full rectal mucosa prolapse.

    PubMed

    Regadas, F Sergio P; Abedrapo, Mario; Cruz, Jose Vinicius; Murad Regadas, Sthela M; Regadas Filho, F Sergio P

    2014-11-01

    The aim of the current study was to demonstrate the use of a modified stapling technique, called the apex technique, to treat rectal intussusception and full rectal mucosal prolapse. It was conducted as a retrospective study at 3 centers (2 in Brazil and 1 in Chile). The apex technique is performed by using a HEM/EEA-33 stapler. A pursestring suture is placed at the apex of the prolapse, on the 4 quadrants, independent of the distance to the dentate line. A second pursestring is then placed to define the band of rectal mucosa to be symmetrically resected. Outcome measures included width of the resected full-thickness rectal wall; the intensity of postoperative pain on a visual analog scale from 1 to 10; full mucosal prolapse and rectal intussusception assessed by physical examination, cinedefecography, or echodefecography; and change in the constipation scale. Forty-five patients (30 women/15 men; mean age, 59.5 years) with rectal intussusception and full mucosal prolapse were included. The median operative time was 17 (range, 15-30) minutes. Bleeding after stapler fire requiring manual suture occurred in 3 patients (6.7%); 25 (55.6%) patients reported having no postoperative pain. Hospital stay was 24 hours. The mean width of the resected rectal wall was 5.9 (range, 5.0-7.5) cm. Stricture at the staple line was seen in 4 patients, of whom 1 required dilation under anesthesia. The median follow-up time was 120 (range, 90-120) days. A small residual prolapse was identified in 6 (13.3%) patients. Imaging demonstrated complete disappearance of rectal intussusception in all patients, and the mean postoperative constipation score decreased from 13 (range, 8-15) to 5 (range, 3-7). The apex technique appears to be a safe, quickly performed, and low-cost method for the treatment of rectal intussusception. In this series, imaging examinations showed the disappearance of rectal intussusception, and a significant decrease in constipation score suggested improvement in

  18. Skin sites to predict deep-body temperature while wearing firefighters' personal protective equipment during periodical changes in air temperature.

    PubMed

    Kim, Siyeon; Lee, Joo-Young

    2016-04-01

    The aim of this study was to investigate stable and valid measurement sites of skin temperatures as a non-invasive variable to predict deep-body temperature while wearing firefighters' personal protective equipment (PPE) during air temperature changes. Eight male firefighters participated in an experiment which consisted of 60-min exercise and 10-min recovery while wearing PPE without self-contained breathing apparatus (7.75 kg in total PPE mass). Air temperature was periodically fluctuated from 29.5 to 35.5 °C with an amplitude of 6 °C. Rectal temperature was chosen as a deep-body temperature, and 12 skin temperatures were recorded. The results showed that the forehead and chest were identified as the most valid sites to predict rectal temperature (R(2) = 0.826 and 0.824, respectively) in an environment with periodically fluctuated air temperatures. This study suggests that particular skin temperatures are valid as a non-invasive variable when predicting rectal temperature of an individual wearing PPE in changing ambient temperatures. Practitioner Summary: This study should offer assistance for developing a more reliable indirect indicating system of individual heat strain for firefighters in real time, which can be used practically as a precaution of firefighters' heat-related illness and utilised along with physiological monitoring.

  19. Rectal tube drainage reduces major anastomotic leakage after minimally invasive rectal cancer surgery.

    PubMed

    Yang, C-S; Choi, G-S; Park, J S; Park, S Y; Kim, H J; Choi, J-I; Han, K S

    2016-12-01

    Anastomotic leakage is the most serious complication following low anterior resection for rectal cancer and is a major cause of postoperative morbidity and mortality. The object of the present study was to investigate whether rectal tube drainage can reduce anastomotic leakage after minimally invasive rectal cancer surgery. Three hundred and seventy-four patients who underwent laparoscopic or robotic LAR for tumours located ≤ 15 cm above the anal verge between 1 April 2012 and 31 October 2014 were assessed retrospectively. Of these, 107 with intermediate risk of anastomotic leakage received transanal rectal tube drainage. The rectal tube group was matched by propensity score analysis with patients not having rectal tube drainage, giving 204 patients in the study. Covariates for propensity score analysis included age, sex, body mass index, tumour height from the anal verge and preoperative chemoradiation. Patient demographics, tumour location, preoperative chemoradiation and operative results were similar between the two groups. The overall leakage rate was 10.8% (22/204), with no significant difference between the rectal tube group (9.8%) and the nonrectal tube group (11.8%, P = 0.652). Of the patients with anastomotic leakage, major leakage requiring reoperation developed in 11.8% of those without and 3.9% of those with a rectal tube. On multivariate analysis, age over 65 years and nonuse of a rectal tube were found to be independent risk factors for major anastomotic leakage. Rectal tube placement may be a safe and effective method of reducing the rate of major anastomotic leakage, alleviating the clinical course of leakage following minimally invasive rectal cancer surgery. Colorectal Disease © 2016 The Association of Coloproctology of Great Britain and Ireland.

  20. Effect of heat stress on milk production, rectal temperature, respiratory rate and blood chemistry in Holstein, Jersey and Australian Milking Zebu cows.

    PubMed

    Srikandakumar, A; Johnson, E H

    2004-10-01

    The effect of heat stress on changes in milk production, rectal temperature, respiratory rate and blood chemistry was evaluated in three groups of six mature Holstein, Jersey and Australian Milking Zebu (AMZ) dairy cows. These animals were subjected to a cool environment when the mean temperature-humidity index (THI) was 72+/-1.4 (dry bulb temperature of 22.2-24.4 degrees C and relative humidity of 100-60%) during the month of December. This experiment was repeated during the hotter month of July of the following year, when the mean THI was 93+/-3.1 (dry bulb temperature of 35.6-43.9 degrees C and relative humidity 95-35%). Holstein cows produced more (p <0.01) milk than AMZ and Jersey cows during the cooler months of the year and all the cows were dry during the hotter months from June until September. Heat stress increased (p<0.01) rectal temperature and respiratory rate in all three breeds. Heat stress had no effect on blood pH in Holstein and AMZ cows but lowered (p <0.01) blood pH from 7.42 to 7.34 in Jersey cows. In addition, heat stress lowered (p <0.01) blood pCO2 (kPa), bicarbonate (HCO3, mmol/L), base excess (BE, mmol/L) and plasma chloride (Cl-, mmol/L) in all three breeds. The total haemoglobin (THb, g/dl) was elevated (p <0.01) in all three breeds when they were subjected to heat stress. Heat stress increased (p<0.01) oxygen saturation (O2SAT, %) in Jersey and AMZ cows but lowered it (p <0.01) in Holstein cows. On the other hand, heat stress increased (p <0.01)pO2 (kPa) in Holstein and Jersey cows but lowered it (p <0.01) in AMZ cows. Heat stress increased (p <0.01) plasma potassium (K, mmol/L) and calcium (Ca, mmol/L) only in Holstein and Jersey cows but lowered them (p<0.01) in AMZ cows. The plasma glucose (GLU, mmol/L) increased (p<0.01) with heat stress in Holstein and AMZ cows but decreased (p <0.01) in Jersey cows. Heat stress increased (p<0.01) plasma creatinine (CR, (mol/L) but lowered (p<0.01) plasma creatinine phosphokinase (CPK, IU

  1. Poloxamer 188 and propylene glycol-based rectal suppository enhances anticancer effect of 5-fluorouracil in mice.

    PubMed

    Paek, Seung-Hwan; Xuan, Jing-Ji; Choi, Han-Gon; Park, Byung Chul; Lee, Yoon-Seok; Jeong, Tae-Cheon; Jin, Chun Hua; Oh, Yu-Kyoung; Kim, Jung-Ae

    2006-05-01

    The tumoricidal and apoptosis-inducing activities of 5-fluorouracil (5-FU) have been demonstrated in experimental and clinical investigations. Clinically, the 5-FU suppository form has been widely adopted for its advantages of less systemic toxicity, higher local tissue concentrations, and reduced first-pass effect. In this study, we investigated the feasibility of rectal administration of 5-FU suppository based on poloxamer 188 (P188) and propylene glycol (PG) and its anticancer effect on the murine experimental cancer models. The rectal suppository was made with 70% P188 and 30% PG, which was a solid phase at room temperature and instantly melted at physiological temperature. The treatment with the 5-FU suppository was more effective than the oral route in decreasing the volume of rectal cancer in mice. In addition, the survival rate of the mice with rectal cancer was higher in the group treated with the 5-FU suppository than in the group treated with 5-FU orally. Furthermore, in mice skin cancers induced by inoculation of murine CT-26 colon carcinoma cells, the anticancer effect of 5-FU was significantly enhanced by the rectal administration of the suppository than by oral treatment. Taken together, the results suggest that a poloxamer gel system with 5-FU/P188/PG is an effective rectal dosage form for the treatment of both rectal and non-rectal cancers.

  2. Bladder urothelial carcinoma extending to rectal mucosa and presenting with rectal bleeding

    PubMed Central

    Aneese, Andrew M; Manuballa, Vinayata; Amin, Mitual; Cappell, Mitchell S

    2017-01-01

    An 87-year-old-man with prostate-cancer-stage-T1c-Gleason-6 treated with radiotherapy in 1996, recurrent prostate cancer treated with leuprolide hormonal therapy in 2009, and bladder-urothelial-carcinoma in situ treated with Bacillus-Calmette-Guerin and adriamycin in 2010, presented in 2015 with painless, bright red blood per rectum coating stools daily for 5 mo. Rectal examination revealed bright red blood per rectum; and a hard, fixed, 2.5 cm × 2.5 cm mass at the normal prostate location. The hemoglobin was 7.6 g/dL (iron saturation = 8.4%, indicating iron-deficiency-anemia). Abdominopelvic-CT-angiography revealed focal wall thickening at the bladder neck; a mass containing an air cavity replacing the normal prostate; and adjacent rectal invasion. Colonoscopy demonstrated an ulcerated, oozing, multinodular, friable, 2.5 cm × 2.5 cm mass in anterior rectal wall, at the usual prostate location. Histologic and immunohistochemical analysis of colonoscopic biopsies of the mass revealed poorly-differentiated-carcinoma of urothelial origin. At visceral angiography, the right-superior-rectal-artery was embolized to achieve hemostasis. The patient subsequently developed multiple new metastases and expired 13 mo post-embolization. Comprehensive literature review revealed 16 previously reported cases of rectal involvement from bladder urothelial carcinoma, including 11 cases from direct extension and 5 cases from metastases. Patient age averaged 63.7 ± 9.6 years (all patients male). Rectal involvement was diagnosed on average 13.5 ± 11.8 mo after initial diagnosis of bladder urothelial carcinoma. Symptoms included constipation/gastrointestinal obstruction-6, weight loss-5, diarrhea-3, anorexia-3, pencil thin stools-3, tenesmus-2, anorectal pain-2, and other-5. Rectal examination in 9 patients revealed annular rectal constriction-6, and rectal mass-3. The current patient had the novel presentation of daily bright red blood per rectum coating the stools simulating

  3. Early rectal stenosis following stapled rectal mucosectomy for hemorrhoids

    PubMed Central

    Petersen, Sven; Hellmich, Gunter; Schumann, Dietrich; Schuster, Anja; Ludwig, Klaus

    2004-01-01

    Background Within the last years, stapled rectal mucosectomy (SRM) has become a widely accepted procedure for second and third degree hemorrhoids. One of the delayed complications is a stenosis of the lower rectum. In order to evaluate the specific problem of rectal stenosis following SRM we reviewed our data with special respect to potential predictive factors or stenotic events. Methods A retrospective analysis of 419 consecutive patients, which underwent SRM from December 1998 to August 2003 was performed. Only patients with at least one follow-up check were evaluated, thus the analysis includes 289 patients with a mean follow-up of 281 days (±18 days). For statistic analysis the groups with and without stenosis were evaluated using the Chi-Square Test, using the Kaplan-Meier statistic the actuarial incidence for rectal stenosis was plotted. Results Rectal stenosis was observed in 9 patients (3.1%), eight of these stenoses were detected within the first 100 days after surgery; the median time to stenosis was 95 days. Only one patient had a rectal stenosis after more than one year. 8 of the 9 patients had no obstructive symptoms, however the remaining patients complained of obstructive defecation and underwent surgery for transanal strictureplasty with electrocautery. A statistical analysis revealed that patients with stenosis had significantly more often prior treatment for hemorrhoids (p < 0.01). According to the SRM only severe postoperative pain was significantly associated with stenoses (p < 0.01). Other factors, such as gender (p = 0.11), surgical technique (p = 0.25), revision (p = 0.79) or histological evidence of squamous skin (p = 0.69) showed no significance. Conclusion Rectal stenosis is an uncommon event after SRM. Early stenosis will occur within the first three months after surgery. The majority of the stenoses are without clinical relevance. Only one of nine patients had to undergo surgery for a relevant stenosis. The predictive factor for

  4. Effect of temperature stress on circulating biogenic amines in bovine.

    PubMed

    Davis, T P; Johnson, H D; Gehrke, C W

    1984-01-01

    A sensitive, simple and selective chromatographic method using high performance liquid chromatography was developed to measure circulating levels of histamine (HI), norepinephrine (NE), dopamine (DA) and serotonin (5-HT) as indicators of response to thermal stress in two breeds of cattle. Duplicate exposures for 8 hr to 13 degrees C resulted in significantly elevated plasma NE and DA in longhorns but not in Herefords and suggest a relatively greater sensitivity to the cold (13 degrees C) in the longhorn. Environmental temperatures of 32 and 42 degrees C significantly increased rectal temperatures of both breeds with much higher rectal temperatures in Herefords. The 32 and 42 degrees C effects on circulating NE and DA of Herefords were highly significant but not in the longhorn. However, heat stress significantly elevated HI and 5-HT in the longhorn which may account for their relatively greater heat tolerance based on their lower rectal temperatures.

  5. Rectal cancer.

    PubMed

    Sexe, Robert; Miedema, Brent W

    1993-07-01

    Preview When in rectal cancer surgery can the anal sphincter be spared? For which patients is iliac lymphadenectomy advisable? Should radiation therapy and chemotherapy be given before surgery rather than after? Drs Sexe and Miedema address these and other questions in this discussion of recent advances and future trends in therapy for rectal cancer.

  6. Effects of multiple concurrent stressors on rectal temperature, blood acid-base status, and longissimus muscle glycolytic potential in market-weight pigs.

    PubMed

    Ritter, M J; Ellis, M; Anderson, D B; Curtis, S E; Keffaber, K K; Killefer, J; McKeith, F K; Murphy, C M; Peterson, B A

    2009-01-01

    Sixty-four market-weight (130.0 +/- 0.65 kg) barrows (n = 16) and gilts (n = 48) were used in a split-plot design with a 2 x 2 x 2 factorial arrangement of treatments: 1) handling intensity (gentle vs. aggressive), 2) transport floor space (0.39 vs. 0.49 m(2)/pig), and 3) distance moved during handling (25 vs. 125 m) to determine the effects of multiple concurrent stressors on metabolic responses. For the handling intensity treatment, pigs were moved individually approximately 50 m through a handling course with either 0 (gentle) or 8 (aggressive) shocks from an electric goad. Pigs were loaded onto a trailer and transported for approximately 1 h at floor spaces of either 0.39 or 0.49 m(2)/pig. After transport, pigs were unloaded, and the distance moved treatment was applied; pigs were moved 25 or 125 m through a handling course using livestock paddles. Rectal temperature was measured, and blood samples (to measure blood acid-base status) were collected 2 h before the handling intensity treatment was applied and immediately after the distance moved treatment was applied. A LM sample to measure glycolytic potential was collected after the distance moved treatments on a subset of 32 pigs. There were handling intensity x distance moved interactions (P < 0.05) for several blood acid-base measurements. In general, there was no effect of distance moved on these traits when pigs were previously handled gently. However, when pigs were previously handled aggressively, pigs moved 125 compared with 25 m had greater (P < 0.05) blood lactate and less (P < 0.05) blood pH, bicarbonate, and base-excess. Pigs transported at 0.39 compared with 0.49 m(2)/pig had a greater (P < 0.01) increase in creatine kinase values; however, transport floor space did not affect any other measurements. Data were analyzed by the number of stressors (the aggressive handling, restricted transport floor space, and 125-m distance moved treatments) experienced by each pig (0, 1, 2, or 3). As the number of

  7. Effect of temperature on thermal acclimation in growing pigs estimated using a nonlinear function.

    PubMed

    Renaudeau, D; Anais, C; Tel, L; Gourdine, J L

    2010-11-01

    Ninety-six Large White growing barrows were used to determine the effect of temperature on thermoregulatory responses during acclimation to increased ambient temperature. Pigs were exposed to 24°C for 10 d and thereafter to a constant temperature of 24, 28, 32, or 36°C for 20 d. The study was conducted in a climate-controlled room at the INRA experimental facilities in Guadeloupe, French West Indies. Relative humidity was kept constant at 80% throughout the experimental period. Rectal temperature, cutaneous temperature, and respiratory rate were measured [breaths per minute (bpm)] 3 times daily (0700, 1200, and 1800 h) every 2 or 3 d during the experiment. The thermal circulation index (TCI) was determined from rectal, cutaneous, and ambient temperature measurements. Changes in rectal temperature, respiratory rate, TCI, and ADFI over the duration of exposure to hot temperatures were modeled using nonlinear responses curves. Within 1 h of exposure to increased temperature, rectal temperature and respiratory rate increased by 0.46°C/d and +29.3 bpm/d, respectively, and ADFI and TCI decreased linearly by 44.7 g•d(-2)•kg(-0.60) and 1.32°C/d, respectively until a first breakpoint time (td(1)). This point marked the end of the short-term heat acclimation phase and the beginning of the long-term heat acclimation period. The td(1) value for ADFI was greater at 28°C than at 32 and 36°C (2.33 vs. 0.31 and 0.26 d, respectively, P < 0.05), whereas td(1) for the TCI increase was greater at 36°C than at 28 and 32°C (1.02 vs. 0.78 and 0.67 d, respectively; P < 0.05). For rectal temperature and respiratory rate responses, td(1) was not influenced by temperature (P > 0.05) and averaged 1.1 and 0.89 d, respectively. For respiratory rate and rectal temperature, the long-term heat acclimation period was divided in 2 phases, with a rapid decline for both variables followed by a slight decrease (P < 0.05). These 2 phases were separated by a second threshold day (td(2)). For

  8. Effect of prewarming on the body temperature of small dogs undergoing inhalation anesthesia.

    PubMed

    Rigotti, Clara F; Jolliffe, Colette T; Leece, Elizabeth A

    2015-10-01

    To investigate whether prewarming affects body temperature of small dogs (weighing < 10 kg [22 lb]) undergoing inhalation anesthesia. Prospective, randomized, blinded clinical trial. Animals: 20 dogs weighing < 10 kg with American Society of Anesthesiologists physical status I or II. Baseline rectal temperature was recorded. Before IM administration of buprenorphine hydrochloride and acepromazine maleate, dogs were randomly assigned to be placed in a pediatric incubator at 33°C (91.4°F) for approximately 30 to 60 minutes (prewarming group) or to receive no prewarming (control group); subsequently, dogs underwent inhalation anesthesia with isoflurane in oxygen. Rectal, esophageal, and ambient temperatures were measured every 5 minutes from induction of anesthesia (IOA) for > 1 hour by an observer who was unaware of treatment. If a dog became hypothermic (esophageal temperature < 36°C [96.8°F]), it was withdrawn from the study. Variables of interest relating to dogs, anesthesia, temperatures, hypothermia, and study withdrawal were compared between groups. 1 dog was excluded from the prewarming group after becoming excessively excited in the incubator. Between groups, age, weight, body condition score, degree of preanesthesia sedation, interval from sedation to IOA, duration of anesthesia, baseline rectal temperature, rectal temperatures immediately prior to IOA, esophageal temperature following IOA, ambient temperature during the first 70 minutes of anesthesia, esophageal or rectal temperature during the first 90 minutes of anesthesia, and incidence of hypothermia and study withdrawal (5 dogs/group) did not differ significantly. Prewarming in an incubator prior to IOA failed to improve or maintain body temperature of dogs weighing < 10 kg during inhalation anesthesia.

  9. Quantification of Organ Motion During Chemoradiotherapy of Rectal Cancer Using Cone-Beam Computed Tomography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chong, Irene; Hawkins, Maria; Hansen, Vibeke

    2011-11-15

    Purpose: There has been no previously published data related to the quantification of rectal motion using cone-beam computed tomography (CBCT) during standard conformal long-course chemoradiotherapy. The purpose of the present study was to quantify the interfractional changes in rectal movement and dimensions and rectal and bladder volume using CBCT and to quantify the bony anatomy displacements to calculate the margins required to account for systematic ({Sigma}) and random ({sigma}) setup errors. Methods and Materials: CBCT images were acquired from 16 patients on the first 3 days of treatment and weekly thereafter. The rectum and bladder were outlined on all CBCTmore » images. The interfraction movement was measured using fixed bony landmarks as references to define the rectal location (upper, mid, and low), The maximal rectal diameter at the three rectal locations was also measured. The bony anatomy displacements were quantified, allowing the calculation of systematic ({Sigma}) and random ({sigma}) setup errors. Results: A total of 123 CBCT data sets were analyzed. Analysis of variance for standard deviation from planning scans showed that rectal anterior and lateral wall movement differed significantly by rectal location. Anterior and lateral rectal wall movements were larger in the mid and upper rectum compared with the low rectum. The posterior rectal wall movement did not change significantly with the rectal location. The rectal diameter changed more in the mid and upper than in the low rectum. No consistent relationship was found between the rectal and bladder volume and time, nor was a significant relationship found between the rectal volume and bladder volume. Conclusions: In the present study, the anterior and lateral rectal movement and rectal diameter were found to change most in the upper rectum, followed by the mid rectum, with the smallest changes seen in the low rectum. Asymmetric margins are warranted to ensure phase 2 coverage.« less

  10. Rectal Cancer Survivors' Participation in Productive Activities.

    PubMed

    Hornbrook, Mark C; Grant, Marcia; Wendel, Christopher; Bulkley, Joanna E; Mcmullen, Carmit K; Altschuler, Andrea; Temple, Larissa Kf; Herrinton, Lisa J; Krouse, Robert S

    2017-01-01

    Rectal cancer and its treatment impair survivors' productivity. To assess determinants of market and nonmarket employment, job search, volunteering, and homemaking among survivors five years or longer after diagnosis. We mailed questionnaires to 1063 survivors who were members of Kaiser Permanente (Northern California, Northwest) during 2010 and 2011. Productive activities, functional health status, and bowel management at the time of the survey. Response rate was 60.5% (577/953). Higher comorbidity burdens were associated with lower productivity for men and women rectal cancer survivors. Productive survivors were younger and had lower disease stage and age at diagnosis, higher household income and educational attainment, and fewer comorbidity burdens and workplace adjustments than did nonproductive survivors (p < 0.05 each; 2-sided). Productive rectal cancer survivors were evenly split by sex. Staying productive is associated with better mental health for rectal cancer survivors. Rectal cancer survivors with multiple chronic conditions, higher disease stage, lower productive activities, and older age need better access to medical care and closer monitoring of the quality of their care, including self-care. To capture the full extent of the involvement of survivors in all types of productive activities, research should routinely include measures of employment, searching for employment, homemaking, and volunteering. Counting market and nonmarket productive activities is innovative and recognizes the continuum of contributions survivors make to families and society. Health care systems should routinely monitor rectal cancer survivors' medical care access, comorbidities, health-related quality of life, and productive activities.

  11. Rectal Microbicide Development

    PubMed Central

    Dezzutti, Charlene

    2014-01-01

    The last few years have seen important progress in demonstrating the efficacy of oral pre-exposure prophylaxis, vaginal microbicides, and treatment as prevention as effective strategies for reducing the risk of acquiring or transmitting HIV infection. There has also been significant progress in the development of rectal microbicides. Preclinical non-human primate studies have demonstrated that antiretroviral microbicides can provide significant protection from rectal challenge with SIV or SHIV. Recent Phase 1 rectal microbicide studies have characterized the safety, acceptability, compartmental pharmacokinetics (PK), and pharmaco-dynamics (PD) of both UC781 and tenofovir gels. The tenofovir gel formulation used in vaginal studies was not well tolerated in the rectum and newer rectal-specific formulations have been developed and evaluated in Phase 1 studies. The PK/PD data generated in these Phase 1 studies may reduce the risk of advancing ineffective candidate rectal microbicides into late stage development. Tenofovir gel is currently poised to move into Phase 2 evaluation and it is possible that a Phase 2B/3 effectiveness study with this product could be initiated in the next 2–3 years. PMID:23612991

  12. Rectal microbicide development.

    PubMed

    McGowan, Ian

    2012-11-01

    Individuals practicing unprotected receptive anal intercourse are at particularly high risk of HIV infection. Men who have sex with men (MSM) in the developed and developing world continue to have disproportionate and increasing levels of HIV infection. The past few years have seen important progress in demonstrating the efficacy of oral pre-exposure prophylaxis (PrEP), vaginal microbicides, and treatment as prevention, but there has also been significant progress in the development of rectal microbicides. The purpose of this review is to summarize the status of rectal microbicide research and to identify opportunities, challenges, and future directions in this important field of HIV prevention. Recent phase 1 rectal microbicide studies have characterized the safety, acceptability, compartmental pharmacokinetics, and pharmacodynamics of both UC781 and tenofovir gels. The tenofovir gel formulation used in vaginal studies was not well tolerated in the rectum and newer rectal-specific formulations have been developed and evaluated in phase 1 studies. Complex phase 1 studies have provided important data on candidate rectal microbicides. Tenofovir gel is poised to move into phase 2 evaluation and it is possible that a phase 2B/3 effectiveness study could be initiated in the next 2-3 years.

  13. Conventional and novel body temperature measurement during rest and exercise induced hyperthermia.

    PubMed

    Towey, Colin; Easton, Chris; Simpson, Robert; Pedlar, Charles

    2017-01-01

    Despite technological advances in thermal sensory equipment, few core temperature (T CORE ) measurement techniques have met the established validity criteria in exercise science. Additionally, there is debate as to what method serves as the most practically viable, yet upholds the proposed measurement accuracy. This study assessed the accuracy of current and novel T CORE measurement techniques in comparison to rectal temperature (T REC ) as a reference standard. Fifteen well-trained subjects (11 male, 4 female) completed 60min of exercise at an intensity equating to the lactate threshold; measured via a discontinuous exercise test. T REC was significantly elevated from resting values (37.2±0.3°C) at the end of moderate intensity exercise (39.6±0.04°C; P=0.001). Intestinal telemetric pill (T PILL ) temperature and temporal artery temperature (T TEM ) did not differ significantly from T REC at rest or during exercise (P>0.05). However, aural canal temperature (T AUR ) and thermal imaging temperature (T IMA ) were both significantly lower than T REC (P<0.05). Bland Altman analysis revealed only T PILL was within acceptable limits of agreement (mean bias; 0.04°C), while T TEM , T AUR and T IMA demonstrated mean bias values outside of the acceptable range (>0.27°C). Against T REC , these results support the use of T PILL over all other techniques as a valid measure of T CORE at rest and during exercise induced hyperthermia. Novel findings illustrate that T IMA (when measured at the inner eye canthus) shows poor agreement to T REC during rest and exercise, which is similar to other 'surface' measures. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.

  14. Chemoradiotherapy response in recurrent rectal cancer.

    PubMed

    Yu, Stanley K T; Bhangu, Aneel; Tait, Diana M; Tekkis, Paris; Wotherspoon, Andrew; Brown, Gina

    2014-02-01

    The efficacy of response to preoperative chemoradiotherapy (CRT) in recurrent versus primary rectal cancer has not been investigated. We compared radiological downsizing between primary and recurrent rectal cancers following CRT and determined the optimal size reduction threshold for response validated by survival outcomes. The proportional change in tumor length for primary and recurrent rectal cancers following CRT was compared using the independent sample t-test. Overall survival (OS) was calculated using the Kaplan-Meier product limit method and differences between survival for tumor size reduction thresholds of 30% (response evaluation criteria in solid tumors [RECIST]), 40%, and 50% after CRT in primary and recurrent rectal cancer groups. A total of 385 patients undergoing CRT were analyzed, 99 with recurrent rectal cancer and 286 with primary rectal cancer. The mean proportional reduction in maximum craniocaudal length was significantly higher for primary rectal tumors (33%) compared with recurrent rectal cancer (11%) (P < 0.01). There was no difference in OS for either primary or recurrent rectal cancer when ≤30% or ≤40% definitions were used. However, for both primary and recurrent tumors, significant differences in median 3-year OS were observed when a RECIST cut-off of 50% was used. OS was 99% versus 77% in primary and 100% versus 42% in recurrent rectal cancer (P = 0.002 and P = 0.03, respectively). Only patients that demonstrated >50% size reduction showed a survival benefit. Recurrent rectal cancer appears radioresistant compared with primary tumors for tumor size after CRT. Further investigation into improving/intensifying chemotherapy and radiotherapy for locally recurrent rectal cancer is justified. © 2013 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.

  15. SU-E-T-280: Reconstructed Rectal Wall Dose Map-Based Verification of Rectal Dose Sparing Effect According to Rectum Definition Methods and Dose Perturbation by Air Cavity in Endo-Rectal Balloon

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, J; Research Institute of Biomedical Engineering, The Catholic University of Korea, Seoul; Park, H

    Purpose: Dosimetric effect and discrepancy according to the rectum definition methods and dose perturbation by air cavity in an endo-rectal balloon (ERB) were verified using rectal-wall (Rwall) dose maps considering systematic errors in dose optimization and calculation accuracy in intensity-modulated radiation treatment (IMRT) for prostate cancer patients. Methods: When the inflated ERB having average diameter of 4.5 cm and air volume of 100 cc is used for patient, Rwall doses were predicted by pencil-beam convolution (PBC), anisotropic analytic algorithm (AAA), and AcurosXB (AXB) with material assignment function. The errors of dose optimization and calculation by separating air cavity from themore » whole rectum (Rwhole) were verified with measured rectal doses. The Rwall doses affected by the dose perturbation of air cavity were evaluated using a featured rectal phantom allowing insert of rolled-up gafchromic films and glass rod detectors placed along the rectum perimeter. Inner and outer Rwall doses were verified with reconstructed predicted rectal wall dose maps. Dose errors and extent at dose levels were evaluated with estimated rectal toxicity. Results: While AXB showed insignificant difference of target dose coverage, Rwall doses underestimated by up to 20% in dose optimization for the Rwhole than Rwall at all dose range except for the maximum dose. As dose optimization for Rwall was applied, the Rwall doses presented dose error less than 3% between dose calculation algorithm except for overestimation of maximum rectal dose up to 5% in PBC. Dose optimization for Rwhole caused dose difference of Rwall especially at intermediate doses. Conclusion: Dose optimization for Rwall could be suggested for more accurate prediction of rectal wall dose prediction and dose perturbation effect by air cavity in IMRT for prostate cancer. This research was supported by the Leading Foreign Research Institute Recruitment Program through the National Research Foundation of

  16. Absorption of phenytoin from rectal suppositories formulated with a polyethylene glycol base.

    PubMed

    Burstein, A H; Fisher, K M; McPherson, M L; Roby, C A

    2000-05-01

    To compare phenytoin pharmacokinetics following administration of an oral suspension and a rectal suppository formulated with a polyethylene glycol base. Unblinded, single-dose, randomized, crossover trial. University-affiliated pharmacokinetics and biopharmaceutics laboratory. Six healthy subjects. Subjects were given a single 200-mg dose of phenytoin as an oral suspension and a rectal suppository separated by a 1-week washout. Blood for plasma phenytoin concentrations was obtained at baseline and 0.5, 1, 2, 4, 6, 8, 10, 12, and 24 hours after administration. Plasma was analyzed by high-performance liquid chromatography (coefficient of variation < 6%) for total phenytoin concentration. Phenytoin maximum concentration (Cmax), time to Cmax (Tmax), time to first measurable concentration (Tlag), and area under the curve from time zero to time of last measurable concentration (AUClast) were estimated for oral and rectal administration by WinNonlin (v 1.1) and compared using Wilcoxon's signed rank test (p<0.05 for statistical significance). Two subjects did not have detectable plasma phenytoin concentrations after rectal administration. For the other four subjects, median rectal Cmax was significantly lower than oral Cmax (0.4 vs 1.9 microg/ml, p=0.028), median rectal Tmax did not differ from oral Tmax (11.9 vs 8.0 hrs, p=0.465), and median rectal AUClast, although highly variable, was significantly lower than oral AUClast (5.4 vs 36.2 microg x hr/ml, p=0.046). No Tlag was seen after oral administration, but with rectal administration the median Tlag was 2 hours. The estimated relative bioavailability of rectal phenytoin suppositories based on AUC0-24 was 4.7%, with individual values ranging from 0-58.3%. It appears that absorption of phenytoin from polyethylene glycol rectal suppositories in healthy subjects is highly variable and unpredictable. Thus this formulation is not recommended.

  17. A study on rectal dose measurement in phantom and in vivo using Gafchromic EBT3 film in IMRT and CyberKnife treatments of carcinoma of prostate

    PubMed Central

    Ganapathy, K.; Kurup, P. G. G.; Murali, V.; Muthukumaran, M.; Subramanian, S. Balaji; Velmurugan, J.

    2013-01-01

    The objective of this study is to check the feasibility of in vivo rectal dose measurement in intensity-modulated radiotherapy (IMRT) and CyberKnife treatments for carcinoma prostate. An in-house pelvis phantom made with bee's wax was used in this study. Two cylindrical bone equivalent materials were used to simulate the femur. Target and other critical structures associated with carcinoma prostate were delineated on the treatment planning images by the radiation oncologist. IMRT treatment plan was generated in Oncentra Master Plan treatment planning system and CyberKnife treatment plan was generated in Multiplan treatment planning system. Dose measurements were carried out in phantom and in patient using Gafchromic EBT3 films. RIT software was used to analyze the dose measured by EBT3 films. The measured doses using EBT3 films were compared with the TPS-calculated dose along the anterior rectal wall at multiple points. From the in-phantom measurements, it is observed that the difference between calculated and measured dose was mostly within 5%, except for a few measurement points. The difference between calculated and measured dose in the in-patient measurements was higher than 5% in regions which were away from the target. Gafchromic EBT3 film is a suitable detector for in vivo rectal dose measurements as it offers the possibility of analyzing the dose at multiple points. In addition, the method of extending this in vivo rectal dose measurement technique as a tool for patient-specific quality assurance check is also analyzed. PMID:24049320

  18. Reliability and validity assessment of administrative databases in measuring the quality of rectal cancer management.

    PubMed

    Corbellini, Carlo; Andreoni, Bruno; Ansaloni, Luca; Sgroi, Giovanni; Martinotti, Mario; Scandroglio, Ildo; Carzaniga, Pierluigi; Longoni, Mauro; Foschi, Diego; Dionigi, Paolo; Morandi, Eugenio; Agnello, Mauro

    2018-01-01

    Measurement and monitoring of the quality of care using a core set of quality measures are increasing in health service research. Although administrative databases include limited clinical data, they offer an attractive source for quality measurement. The purpose of this study, therefore, was to evaluate the completeness of different administrative data sources compared to a clinical survey in evaluating rectal cancer cases. Between May 2012 and November 2014, a clinical survey was done on 498 Lombardy patients who had rectal cancer and underwent surgical resection. These collected data were compared with the information extracted from administrative sources including Hospital Discharge Dataset, drug database, daycare activity data, fee-exemption database, and regional screening program database. The agreement evaluation was performed using a set of 12 quality indicators. Patient complexity was a difficult indicator to measure for lack of clinical data. Preoperative staging was another suboptimal indicator due to the frequent missing administrative registration of tests performed. The agreement between the 2 data sources regarding chemoradiotherapy treatments was high. Screening detection, minimally invasive techniques, length of stay, and unpreventable readmissions were detected as reliable quality indicators. Postoperative morbidity could be a useful indicator but its agreement was lower, as expected. Healthcare administrative databases are large and real-time collected repositories of data useful in measuring quality in a healthcare system. Our investigation reveals that the reliability of indicators varies between them. Ideally, a combination of data from both sources could be used in order to improve usefulness of less reliable indicators.

  19. Rectal Dose and Source Strength of the High-Dose-Rate Iridium-192 Both Affect Late Rectal Bleeding After Intracavitary Radiation Therapy for Uterine Cervical Carcinoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Isohashi, Fumiaki, E-mail: isohashi@radonc.med.osaka-u.ac.j; Yoshioka, Yasuo; Koizumi, Masahiko

    2010-07-01

    Purpose: The purpose of this study was to reconfirm our previous findings that the rectal dose and source strength both affect late rectal bleeding after high-dose-rate intracavitary brachytherapy (HDR-ICBT), by using a rectal dose calculated in accordance with the definitions of the International Commission on Radiation Units and Measurements Report 38 (ICRU{sub RP}) or of dose-volume histogram (DVH) parameters by the Groupe Europeen de Curietherapie of the European Society for Therapeutic Radiology and Oncology. Methods and Materials: Sixty-two patients who underwent HDR-ICBT and were followed up for 1 year or more were studied. The rectal dose for ICBT was calculatedmore » by using the ICRP{sub RP} based on orthogonal radiographs or the DVH parameters based on computed tomography (CT). The total dose was calculated as the biologically equivalent dose expressed in 2-Gy fractions (EQD{sub 2}). The relationship between averaged source strength or the EQD{sub 2} and late rectal bleeding was then analyzed. Results: When patients were divided into four groups according to rectal EQD{sub 2} ({>=} or =} or <2.4 cGy.m{sup 2}.h{sup -1}), the group with both a high EQD{sub 2} and a high source strength showed a significantly greater probability of rectal bleeding for ICRU{sub RP}, D{sub 2cc}, and D{sub 1cc}. The patients with a median rectal dose above the threshold level did not show a greater frequency of rectal bleeding unless the source strength exceeded 2.4 cGy.m{sup 2}.h{sup -1}. Conclusions: Our results obtained with data based on ICRU{sub RP} and CT-based DVH parameters indicate that rectal dose and source strength both affect rectal bleeding after HDR-ICBT.« less

  20. Strangulation of giant rectal prolapse.

    PubMed

    El Moussaoui, Imad; Limbga, Augustin; Dika, Manke; Mehdi, Abdelilah

    2018-01-01

    Introduction Rectal prolapse is the complete protrusion of the rectum through the anal canal, incarceration rarely complicates rectal prolapse. Even more rarely, it becomes strangulated and gangrenous, necessitating emergency surgery. Case presentation We present the first reported case of strangulated acute rectal prolapse as the first manifestation of rectal prolapse. The patient was a 26-year-old man who presented with a 20×6 cm semi-spherical mass extra-anally. Rectosigmoidectomy with sacral rectopexy was performed, resecting 20 cm of the incarcerated rectum and sigmoid colon. The postoperative course was uneventful with a good final result after colostomy closure and continuity restoration. Conclusion The successful treatment of this patient illustrates the value of surgery in this difficult and unusual case scenario of rectal incarceration.

  1. Rectal cancer: a review

    PubMed Central

    Fazeli, Mohammad Sadegh; Keramati, Mohammad Reza

    2015-01-01

    Rectal cancer is the second most common cancer in large intestine. The prevalence and the number of young patients diagnosed with rectal cancer have made it as one of the major health problems in the world. With regard to the improved access to and use of modern screening tools, a number of new cases are diagnosed each year. Considering the location of the rectum and its adjacent organs, management and treatment of rectal tumor is different from tumors located in other parts of the gastrointestinal tract or even the colon. In this article, we will review the current updates on rectal cancer including epidemiology, risk factors, clinical presentations, screening, and staging. Diagnostic methods and latest treatment modalities and approaches will also be discussed in detail. PMID:26034724

  2. Local Hypothermia as a Radioprotector of the Rectal Wall During Prostate Stereotactic Body Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hrycushko, Brian A., E-mail: Brian.Hrycushko@utsouthwestern.edu; Chopra, Rajiv; Sayre, James W.

    Purpose: To compare the single-fraction dose-related incidence of rectal obstruction and/or bleeding in normothermic and hypothermic rectums of a rat model. Methods and Materials: A 1.9-cm length of rectum was irradiated with a single fraction in 57 Sprague-Dawley rats using a dedicated image-guided small animal irradiator and Monte Carlo–based treatment planning system. All rats had a rectal temperature control apparatus placed during irradiation and were stratified to achieve either a normothermic (37°C) or hypothermic (15°C) rectal wall temperature. Radiation was delivered to a 1-cm-diameter cylindrical volume about the cooling device and rectal wall. The radiation dose was escalated from 16 Gy upmore » to 37 Gy to assess the dose response in each arm. The primary endpoint of this study was rectal obstruction and/or bleeding during a follow-up of 180 to 186 days. Histologic scoring was performed on all study rats. Results: Probit analysis showed a dose associated with a 50% incidence of rectal obstruction of 24.6 Gy and 40.8 Gy for normothermic and hypothermic arms, respectively. The occurrence of obstruction and/or bleeding correlated with the posttreatment histologic score for normothermic rats; however, there was no difference in histologic score between normothermic and hypothermic rats at the highest dose levels evaluated. Conclusions: A significant radioprotective effect was observed using local hypothermia during a single large dose of radiation for the functional endpoint of rectal obstruction and/or bleeding. A confirmatory study in a large animal model with anatomic and physiologic similarities to humans is suggested.« less

  3. Relationship among eye temperature measured using digital infrared thermal imaging and vaginal and rectal temperatures in hair sheep and cattle

    USDA-ARS?s Scientific Manuscript database

    Digital infrared thermal imaging (DITI) using a thermal camera has potential to be a useful tool for the production animal industry. Thermography has been used in both humans and a wide range of animal species to measure body temperature as a method to detect injury or inflammation. The objective of...

  4. Miniaturized implantable sensors for in vivo localized temperature measurements in mice during cold exposure.

    PubMed

    Padovani, R; Lehnert, T; Cettour-Rose, P; Doenlen, R; Auwerx, J; Gijs, M A M

    2016-02-01

    We report on in vivo temperature measurements performed in mice at two specific sites of interest in the animal body over a period of several hours. In particular, the aim of this work was to monitor mouse metabolism during cold exposure, and to record possible temperature differences between the body temperature measured in the abdomen and the temperature of the brown adipose tissue (BAT) situated in the interscapular area. This approach is of biological interest as it may help unravelling the question whether biochemical activation of BAT is associated with local increase in metabolic heat production. For that purpose, miniaturized thermistor sensors have been accurately calibrated and implanted in the BAT and in the abdominal tissue of mice. After 1 week of recovery from surgery, mice were exposed to cold (6 °C) for a maximum duration of 6 h and the temperature was acquired continuously from the two sensors. Control measurements with a conventional rectal probe confirmed good performance of both sensors. Moreover, two different mouse phenotypes could be identified, distinguishable in terms of their metabolic resistance to cold exposure. This difference was analyzed from the thermal point of view by computational simulations. Our simple physical model of the mouse body allowed to reproduce the global evolution of hypothermia and also to explain qualitatively the temperature difference between abdomen and BAT locations. While with our approach, we have demonstrated the importance and feasibility of localized temperature measurements on mice, further optimization of this technique may help better identify local metabolism variations.

  5. Resolution of Rectal Prolapse by Vaginal Reconstruction.

    PubMed

    Devakumar, Hemikaa; Chandrasekaran, Neeraja; Alas, Alexandriah; Martin, Laura; Davila, G Willy; Hurtado, Eric

    Rectal prolapse is a disorder of the pelvic floor in which the layers of the rectal mucosa protrude outward through the anus. Surgical repair is the mainstay of treatment. Options include intra-abdominal procedures such as rectopexy and perineal procedures such as the Delorme and Altemeier perineal rectosigmoidectomy. Rectal and vaginal prolapse can often coexist. However, to our knowledge, there are no reported cases of rectal prolapse resolved by the repair of a compressive enterocele abutting the anterior rectal wall through a vaginal approach alone. We present a novel case of rectal prolapse that resolved by correction of the vaginal defect. A 53-year-old female with prior history of abdominal hysterectomy, presented to the urogynecology clinic with complaints of vaginal bulge, urge urinary incontinence, and rectal bulge on straining with no fecal incontinence for several years. On physical examination, she was found to have stage 2 anterior, posterior, and apical vaginal prolapse and reducible rectal prolapse. Colorectal surgery (CRS) evaluation was requested, which revealed minimal anterior mucosal prolapse on Valsalva with no full-thickness prolapse. Magnetic resonance imaging (MRI) defecogram was performed, which demonstrated a large rectocele, enterocele, and small bowel prolapsing between the rectum and vagina during the evacuation phase, with no rectal prolapse. The decision to proceed with vaginal prolapse surgery without concomitant rectal prolapse repair was made, as the patient had no fecal incontinence, and the degree of rectal prolapse was minimal. On the day of surgery, which was 2 months later, she presented with a 2-cm anterior rectal prolapse with no incontinence. Colorectal surgery was consulted again, but unavailable. After counseling, the patient wished to proceed with her planned surgery. It was felt that correcting the anterior rectocele and enterocele, thereby eliminating the descent of the bowel on the anterior rectal wall, might cause

  6. Rectal nitric oxide and fecal calprotectin in inflammatory bowel disease.

    PubMed

    Reinders, Claudia A; Jonkers, Daisy; Janson, Emmellie A; Stockbrügger, Reinhold W; Stobberingh, Ellen E; Hellström, Per M; Lundberg, Jon O

    2007-10-01

    The assessment of intestinal inflammation in patients with inflammatory bowel disease (IBD) remains a difficult challenge. Both rectal nitric oxide (NO) and fecal calprotectin can be measured using non-invasive methods and are emerging as promising inflammatory markers in IBD. In this study the aim was to compare calprotectin and NO levels in IBD patients. Rectal NO was measured tonometrically in 23 healthy volunteers and 32 patients with IBD. In addition, we collected stool samples from all subjects for measurement of fecal calprotectin and nitrate/nitrite (NO metabolites). Patients with IBD had greatly increased NO and calprotectin levels compared to healthy volunteers (p <0.001). In addition, the nitrate levels were slightly increased in IBD patients. A weak correlation was found between rectal NO levels, disease activity and number of loose stools in IBD patients (Spearman's rho 0.37 and 0.51, respectively; p <0.05). Fecal calprotectin correlated only with age (Spearman's rho 0.51; p <0.01). However, no correlation was found between NO and calprotectin. Both rectal NO and fecal calprotectin are greatly increased during bowel inflammation, but they may reflect different parts of the inflammatory process. Future studies will elucidate the clinical usefulness of these two markers.

  7. [Heat exchange of the rat in thermoneutral zone temperature and comparison with heat exchange in ambient temperature over and under it].

    PubMed

    Rumiantsev, G V

    2011-08-01

    With the help of thermonetry and general calorimetry body temperature and heat production in ambient temperatures 20 degrees C, 28 degrees C, 33 degrees C were recorded. The experiments showed, that at the temperature 20 degrees C the rectal temperature was changing very little. But in ambient temperature 33 degrees C the rectal temperature was 40.5 +/- 0.1 degrees C.

  8. Comparison between in vivo dosimetry and barium contrast technique for prediction of rectal complications in high-dose-rate intracavitary radiotherapy in cervix cancer patients.

    PubMed

    Huh, Seung Jae; Lim, Do Hoon; Ahn, Yong Chan; Lee, Jeong Eun; Kang, Min Kyu; Shin, Seong Soo; Shin, Kyung Hwan; Kim, Bokyung; Park, Won; Han, Youngyih

    2003-03-01

    To investigate the correlation between late rectal complications and rectal dose in cervix cancer patients treated with high-dose-rate intracavitary radiotherapy (HDR ICR) and to analyze factors reducing rectal complications. A total of 136 patients with cervix cancer who were treated with external beam radiotherapy (EBRT) and HDR ICR from 1995 to 1999 were retrospectively analyzed. Radiotherapy (RT) consisted of EBRT plus HDR ICR. The median EBRT dose was 50.4 Gy, and midline block was done after 30-50 Gy of EBRT. A total of six fractions of HDR ICR with 4 Gy fraction size each were applied twice per week to the A point. The rectal dose was calculated at the rectal reference point using the barium contrast criteria. In vivo measurement of the rectal dose was performed with thermoluminescent dosimeter (TLD) during HDR ICR. The median follow-up period was 26 months (range 6-60 months). A total of 16 patients (12%) experienced rectal bleeding, which occurred 4-33 months (median 11 months) after the completion of RT. The calculated rectal doses did not differ in patients with rectal bleeding and those without, but the measured rectal doses were higher in affected patients. The differences of the measured ICR fractional rectal dose, ICR total rectal dose, and total rectal biologically equivalent dose (BED) were statistically significant. When the measured ICR total rectal dose exceeded 16 Gy, the ratio of the measured rectal dose to A point dose was > 70%; when the measured rectal BED exceeded 110 Gy(3), a high possibility of late rectal complications could be found. In vivo dosimetry using TLD during HDR ICR was a good predictor of late rectal complications. Hence, if data from in vivo dosimetry shows any possibility of rectal bleeding, efforts should be made to reduce the rectal dose.

  9. Interaction between preprandial and postprandial rectal sensory and motor abnormalities in IBS.

    PubMed

    Törnblom, Hans; Van Oudenhove, Lukas; Tack, Jan; Simrén, Magnus

    2014-09-01

    Rectal sensory and motor interactions in patients with IBS have not been studied in detail. The aim of this study was to evaluate fasting and postprandial rectal sensorimotor characteristics and their interactions in IBS compared with healthy controls. We included 274 patients with IBS and 34 controls. All subjects underwent a rectal barostat study before and 60 min after a standardised liquid meal (800 kcal; 60% fat). Sensory thresholds, intensity of sensations, viscerosomatic referral and compliance were measured. During 15 min before the first distension sequence and until 50 min after meal intake, rectal balloon volumes were registered in 5 min intervals at operating pressure to quantify rectal tone. Mixed models were used to analyse the rectal tone response over time. Rectal sensory thresholds and compliance were decreased and viscerosomatic referral areas increased in patients with IBS compared with controls. Meal intake increased rectal sensitivity, compliance and referral areas in patients and controls and the same proportions of patients were hypersensitive to distension before and after meal intake. There was a higher basal rectal tone in IBS and a significantly different rectal tone response after meal intake in patients with IBS compared with controls and, interestingly, also in IBS with rectal hypersensitivity (defined in the preprandial state), compared with normosensitive patients. Meal intake affects rectal sensorimotor function in IBS and health. Importantly, the rectal tone responses to a high-caloric meal are different between patients with IBS and controls, as well as between hypersensitive and normosensitive patients with IBS. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  10. RECTAL-SPECIFIC MICROBICIDE APPLICATOR: EVALUATION AND COMPARISON WITH A VAGINAL APPLICATOR USED RECTALLY

    PubMed Central

    Carballo-Diéguez, Alex; Giguere, Rebecca; Dolezal, Curtis; Bauermeister, José; Leu, Cheng-Shiun; Valladares, Juan; Rohan, Lisa C.; Anton, Peter A.; Cranston, Ross D.; Febo, Irma; Mayer, Kenneth; McGowan, Ian

    2014-01-01

    An applicator designed for rectal delivery of microbicides was tested for acceptability by 95 young men who have sex with men, who self-administered 4mL of placebo gel prior to receptive anal intercourse over 90 days. Subsequently, 24 of the participants self-administered rectally 4mL of tenofovir or placebo gel over 7 days using a vaginal applicator, and compared both applicators on a Likert scale of 1–10, with 10 the highest rating. Participants reported high likelihood to use either applicator in the future (mean scores 9.3 and 8.8 respectively, p= ns). Those who tested both liked the vaginal applicator significantly more than the rectal applicator (7.8 vs. 5.2, p=0.003). Improvements in portability, conspicuousness, aesthetics, tip comfort, product assembly and packaging were suggested for both. This rectal-specific applicator was not superior to a vaginal applicator. While likelihood of future use is reportedly high, factors that decrease acceptability may erode product use over time in clinical trials. Further attention is needed to develop user-friendly, quick-acting rectal microbicide delivery systems. PMID:24858481

  11. Clinical relevance of pre-ovulatory follicular temperature in heat-stressed lactating dairy cows.

    PubMed

    López-Gatius, F; Hunter, Rhf

    2017-06-01

    Temperature gradients in female reproductive tissues seem to influence the success of key processes such as ovulation and fertilization. The objective of this study was to investigate whether pre-ovulatory follicles are cooler than neighbouring uterine tissue and deep rectal temperatures in lactating dairy cows under heat stress conditions. Temperatures within the pre-ovulatory follicle, on the uterine adjacent surface and 20 cm deep within rectum, were measured using fine thermistor probes within 45 min after sunrise (dawn). Cows were selected from synchronized groups for fixed-time insemination during the warm period of the year. Five cows under direct sun radiation and 11 cows in the shade were included in the study. None of the cows in the sun area ovulated within 24 hr, whereas 10 of the 11 cows in the sun area ovulated. Four of the 10 ovulating cows became pregnant. In the ovulating cows, follicular temperatures were 0.74 and 1.54°C significantly cooler than uterine surface and rectal temperatures, respectively, whereas temperatures in the uterine area were 0.80°C significantly cooler than rectal temperatures. No significant differences among temperatures were found in non-ovulating cows. Follicular size was similar for ovulating and non-ovulating cows. Environmental temperatures in the shade area were 6.4°C significantly lower than those in the sun area. Results of this study indicate that pre-ovulatory follicles are cooler than neighbouring uterine tissue and deep rectal temperatures and those temperature gradients were not found in cows suffering ovulation failure. © 2017 Blackwell Verlag GmbH.

  12. Quantitative analysis of rectal cancer by spectral domain optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Zhang, Q. Q.; Wu, X. J.; Tang, T.; Zhu, S. W.; Yao, Q.; Gao, Bruce Z.; Yuan, X. C.

    2012-08-01

    To quantify OCT images of rectal tissue for clinic diagnosis, the scattering coefficient of the tissue is extracted by curve fitting the OCT signals to a confocal single model. A total of 1000 measurements (half and half of normal and malignant tissues) were obtained from 16 recta. The normal rectal tissue has a larger scattering coefficient ranging from 1.09 to 5.41 mm-1 with a mean value of 2.29 mm-1 (std:±0.32), while the malignant group shows lower scattering property and the values ranging from 0.25 to 2.69 mm-1 with a mean value of 1.41 mm-1 (std:±0.18). The peri-cancer of recta has also been investigated to distinguish the difference between normal and malignant rectal tissue. The results demonstrate that the quantitative analysis of the rectal tissue can be used as a promising diagnostic criterion of early rectal cancer, which has great value for clinical medical applications.

  13. Is endoscopic ultrasonography essential for endoscopic resection of small rectal neuroendocrine tumors?

    PubMed Central

    Park, Su Bum; Kim, Dong Jun; Kim, Hyung Wook; Choi, Cheol Woong; Kang, Dae Hwan; Kim, Su Jin; Nam, Hyeong Seok

    2017-01-01

    AIM To evaluate the importance of endoscopic ultrasonography (EUS) for small (≤ 10 mm) rectal neuroendocrine tumor (NET) treatment. METHODS Patients in whom rectal NETs were diagnosed by endoscopic resection (ER) at the Pusan National University Yangsan Hospital between 2008 and 2014 were included in this study. A total of 120 small rectal NETs in 118 patients were included in this study. Histologic features and clinical outcomes were analyzed, and the findings of endoscopy, EUS and histology were compared. RESULTS The size measured by endoscopy was not significantly different from that measured by EUS and histology (r = 0.914 and r = 0.727 respectively). Accuracy for the depth of invasion was 92.5% with EUS. No patients showed invasion of the muscularis propria or metastasis to the regional lymph nodes. All rectal NETs were classified as grade 1 and demonstrated an L-cell phenotype. Mean follow-up duration was 407.54 ± 374.16 d. No patients had local or distant metastasis during the follow-up periods. CONCLUSION EUS is not essential for ER in the patient with small rectal NETs because of the prominent morphology and benign behavior. PMID:28373770

  14. Application of radio frequency based digital thermometer for real-time monitoring of dairy cattle rectal temperature

    PubMed Central

    Debnath, Tridib; Bera, Santanu; Deb, Suman; Pal, Prasenjit; Debbarma, Nibash; Haldar, Avijit

    2017-01-01

    Aim: Dairy cattle health monitoring program becomes vital for detecting the febrile conditions to prevent the outbreak of the animal diseases as well as ensuring the fitness of the animals that are directly affecting the health of the consumers. The aim of this study was to validate real-time rectal temperature (RT) data of radio frequency based digital (RFD) thermometer with RT data of mercury bulb (MB) thermometer in dairy cattle. Materials and Methods: Two experiments were conducted. In experiment I, six female Jersey crossbred cattle with a mean (±standard error of the mean) body weight of 534.83±13.90 kg at the age of 12±0.52 years were used to record RT for 2 h on empty stomach and 2 h after feeding at 0, 30, 60, 90, and 120 min using a RFD thermometer as well as a MB thermometer. In experiment II, six female Jersey crossbred cattle were further used to record RT for 2 h before exercise and 2 h after exercise at 0, 30, 60, 90, and 120 min. Two-way repeated measures analysis of variance with post hoc comparisons by Bonferroni test was done. Results: Real-time RT data recorded by RFD thermometer as well as MB thermometer did not differ (p>0.05) before and after feeding/exercise. An increase (p<0.05) in RT after feeding/exercise in experimental crossbred cattle was recorded by both RFD thermometer and MB thermometer. Conclusion: The results obtained in the present study suggest that the body temperature recordings from RFD thermometer would be acceptable and thus RFD thermometer could work well for monitoring real-time RT in cattle. PMID:29062193

  15. Application of radio frequency based digital thermometer for real-time monitoring of dairy cattle rectal temperature.

    PubMed

    Debnath, Tridib; Bera, Santanu; Deb, Suman; Pal, Prasenjit; Debbarma, Nibash; Haldar, Avijit

    2017-09-01

    Dairy cattle health monitoring program becomes vital for detecting the febrile conditions to prevent the outbreak of the animal diseases as well as ensuring the fitness of the animals that are directly affecting the health of the consumers. The aim of this study was to validate real-time rectal temperature (RT) data of radio frequency based digital (RFD) thermometer with RT data of mercury bulb (MB) thermometer in dairy cattle. Two experiments were conducted. In experiment I, six female Jersey crossbred cattle with a mean (±standard error of the mean) body weight of 534.83±13.90 kg at the age of 12±0.52 years were used to record RT for 2 h on empty stomach and 2 h after feeding at 0, 30, 60, 90, and 120 min using a RFD thermometer as well as a MB thermometer. In experiment II, six female Jersey crossbred cattle were further used to record RT for 2 h before exercise and 2 h after exercise at 0, 30, 60, 90, and 120 min. Two-way repeated measures analysis of variance with post hoc comparisons by Bonferroni test was done. Real-time RT data recorded by RFD thermometer as well as MB thermometer did not differ (p>0.05) before and after feeding/exercise. An increase (p<0.05) in RT after feeding/exercise in experimental crossbred cattle was recorded by both RFD thermometer and MB thermometer. The results obtained in the present study suggest that the body temperature recordings from RFD thermometer would be acceptable and thus RFD thermometer could work well for monitoring real-time RT in cattle.

  16. 21 CFR 876.5450 - Rectal dilator.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Rectal dilator. 876.5450 Section 876.5450 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5450 Rectal dilator. (a) Identification. A rectal...

  17. 21 CFR 876.5450 - Rectal dilator.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Rectal dilator. 876.5450 Section 876.5450 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5450 Rectal dilator. (a) Identification. A rectal...

  18. In vitro and in vivo characteristics of a thermogelling rectal delivery system of etodolac.

    PubMed

    Barakat, Nahla S

    2009-01-01

    Rectal etodolac-Poloxamer gel systems composed of Poloxamer and bioadhesive polymers were developed and evaluated. Hydroxypropylmethyl cellulose, poly)vinyl) pyrrolidone, methyl cellulose, hydroxyethylcellulose, and carbopol were examined as mucoadhesive polymers. The characteristics of the rectal gels differed according to the properties of mucoadhesive polymers. The physicochemical properties such as gelation temperature, gel strength, and bioadhesive force of various formulations were investigated. The analysis of release mechanism showed that the release of etodolac was proportional to the square root of time, indicating that etodolac might be released from the suppositories by Fickian diffusion. The anti-inflammatory effect of etodolac-Poloxamer gel system was also studied in rats. Moreover, liquid suppository of etodolac did not cause any morphological damage to the rectal tissues. These results suggested that in situ gelling liquid suppository with etodolac and mucoadhesive polymer was a physically safe, convenient, and effective rectal dosage form for etodolac.

  19. Proactive rectal warming during total-gland prostate cryoablation.

    PubMed

    Chen, Chung-Hsin; Pu, Yeong-Shiau

    2014-06-01

    Proactive rectal warming (PRW), as a modification of prostate cryoablation, was assessed in terms of rectal complications and therapeutic outcomes. A cohort of 166 patients cumulatively treated between September, 2009 and November, 2012 qualified for study, each undergoing total-gland cryoablation (TGC) for prostate cancer. The initial 100 patients accrued submitted to TGC alone. PRW was administered to the final 66 patients. Preemptive warming is achieved by inserting a cryoprobe midline through perineal skin into anterior rectal wall under ultrasound guidance. The activated probe generates warmth as the ice ball encroaches on rectum. Prospective, post-ablative grading of rectal pain was measured at weeks 1, 2, 4, 8, 12, and 24 by using the Common Terminology Criteria for Adverse Events. Recurrent prostate cancer was gauged by Phoenix criterion (nadir+2 ng/ml). The Mann-Whitney U test and Chi-square test were used to compare clinical characteristics of therapeutic subsets. The Cox proportional hazard model was applied for comparison of cancer recurrence risk by group. Rectal pain (all grades) was experienced by patients treated with (62%) and without (74%) PRW. Although such pain typically resolved with time, it was milder (general lineal model, p=0.023) and less prolonged (median: 0.75 vs 1.5 months; log-rank test, p=0.002) in patients receiving PRW than in controls. Of note, PRW did not heighten cancer recurrence risk (hazard ratio=1.3 [95% CI, 0.3-5.0]). PRW helps to protect the rectum from freeze injury during prostate cryoablation, significantly reducing post-ablative rectal pain without compromising therapeutic outcomes. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Sexual Function in Males After Radiotherapy for Rectal Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bruheim, Kjersti, E-mail: Kjersti.bruheim@medisin.uio.n; Guren, Marianne G.; Dahl, Alv A.

    Purpose: Knowledge of sexual problems after pre- or postoperative radiotherapy (RT) with 50 Gy for rectal cancer is limited. In this study, we aimed to compare self-rated sexual functioning in irradiated (RT+) and nonirradiated (RT-) male patients at least 2 years after surgery for rectal cancer. Methods and Materials: Patients diagnosed with rectal cancer from 1993 to 2003 were identified from the Norwegian Rectal Cancer Registry. Male patients without recurrence at the time of the study. The International Index of Erectile Function, a self-rated instrument, was used to assess sexual functioning, and serum levels of serum testosterone were measured. Results:more » Questionnaires were returned from 241 patients a median of 4.5 years after surgery. The median age was 67 years at survey. RT+ patients (n = 108) had significantly poorer scores for erectile function, orgasmic function, intercourse satisfaction, and overall satisfaction with sex life compared with RT- patients (n = 133). In multiple age-adjusted analysis, the odds ratio for moderate-severe erectile dysfunction in RT+ patients was 7.3 compared with RT- patients (p <0.001). Furthermore, erectile dysfunction of this degree was associated with low serum testosterone (p = 0.01). Conclusion: RT for rectal cancer is associated with significant long-term effects on sexual function in males.« less

  1. Cost-effectiveness of laparoscopy in rectal cancer.

    PubMed

    Keller, Deborah S; Champagne, Bradley J; Reynolds, Harry L; Stein, Sharon L; Delaney, Conor P

    2014-05-01

    There is an increasing trend to use laparoscopy for rectal cancer surgery. Although laparoscopic and open rectal resections appear oncologically equivalent, there is little information on the cost of different surgical approaches. With the current health care crisis and the importance of optimizing health care resources and patient outcomes, the cost of care is an important factor. The aim of this study was to evaluate the cost-effectiveness of laparoscopy in rectal cancer. This was a case-matched study. This study was conducted at a tertiary referral center. Patients undergoing elective rectal cancer resection between 2007 and 2012 were selected. A review of a prospective database for elective laparoscopic rectal cancer resections was performed. Laparoscopic cases were matched to open cases based on age, BMI, operative procedure, and diagnostic-related group. The primary outcomes measured were the cost of care, hospital length of stay, discharge disposition, readmission, postoperative complications, and mortality rates. Two hundred fifty-four matched cases were included in the analysis: 125 laparoscopic (49%) and 129 open (51%). The cTNM stage (p = 0.39), tumor distance from the anal verge (p = 0.07), and rate of neoadjuvant therapy received between the laparoscopic and open groups were similar (p = 0.12). Operating time (p< 0.01) and cost per operating room minute (p = 0.04) were significantly higher in the open group. The groups were oncologically equivalent, based on circumferential resection margin (p = 0.15). The laparoscopic group had a significantly shorter length of stay (p < 0.01) and lower total hospital cost (p < 0.01). Postoperative complications, 30-day readmission, reoperation, and mortality rates were similar. However, significantly more patients undergoing open resection required intensive care unit care (p = 0.03), skilled nursing (p = 0.03), or home care services (p < 0.01) at discharge. This investigation was conducted at a single institution

  2. Afterrise: Deep Body Temperature Following Exercise

    DTIC Science & Technology

    1992-03-01

    Egalement, les effets de la posture et des v~tements durant la recuperation et la temperature de la salle de recuperation furent examines. Cinq hommes se...chemise a manches courtes). Les temperatures rectales et de la peau furent mesurees A chaque minute durant les exercices et la r~cup~ration affectaient...overgarment. RESUME Cette etude fut entreprise pour documenter l’augmentation continue de la temperature rectale apres exercice dans la chaleur

  3. Brain temperature in volunteers subjected to intranasal cooling.

    PubMed

    Covaciu, L; Weis, J; Bengtsson, C; Allers, M; Lunderquist, A; Ahlström, H; Rubertsson, S

    2011-08-01

    Intranasal cooling can be used to initiate therapeutic hypothermia. However, direct measurement of brain temperature is difficult and the intra-cerebral distribution of temperature changes with cooling is unknown. The purpose of this study was to measure the brain temperature of human volunteers subjected to intranasal cooling using non-invasive magnetic resonance (MR) methods. Intranasal balloons catheters circulated with saline at 20°C were applied for 60 min in ten awake volunteers. No sedation was used. Brain temperature changes were measured and mapped using MR spectroscopic imaging (MRSI) and phase-mapping techniques. Heart rate and blood pressure were monitored throughout the experiment. Rectal temperature was measured before and after the cooling. Mini Mental State Examination (MMSE) test and nasal inspection were done before and after the cooling. Questionnaires about the subjects' personal experience were completed after the experiment. Brain temperature decrease measured by MRSI was -1.7 ± 0.8°C and by phase-mapping -1.8 ± 0.9°C (n = 9) at the end of cooling. Spatial distribution of temperature changes was relatively uniform. Rectal temperature decreased by -0.5 ± 0.3°C (n = 5). The physiological parameters were stable and no shivering was reported. The volunteers remained alert during cooling and no cognitive dysfunctions were apparent in the MMSE test. Postcooling nasal examination detected increased nasal secretion in nine of the ten volunteers. Volunteers' acceptance of the method was good. Both MR techniques revealed brain temperature reductions after 60 min of intranasal cooling with balloons circulated with saline at 20°C in awake, unsedated volunteers.

  4. General Information about Rectal Cancer

    MedlinePlus

    ... Research Rectal Cancer Treatment (PDQ®)–Patient Version General Information About Rectal Cancer Go to Health Professional Version ... the PDQ Adult Treatment Editorial Board . Clinical Trial Information A clinical trial is a study to answer ...

  5. Evaluation of linear array MOSFET detectors for in vivo dosimetry to measure rectal dose in HDR brachytherapy.

    PubMed

    Haughey, Aisling; Coalter, George; Mugabe, Koki

    2011-09-01

    The study aimed to assess the suitability of linear array metal oxide semiconductor field effect transistor detectors (MOSFETs) as in vivo dosimeters to measure rectal dose in high dose rate brachytherapy treatments. The MOSFET arrays were calibrated with an Ir192 source and phantom measurements were performed to check agreement with the treatment planning system. The angular dependence, linearity and constancy of the detectors were evaluated. For in vivo measurements two sites were investigated, transperineal needle implants for prostate cancer and Fletcher suites for cervical cancer. The MOSFETs were inserted into the patients' rectum in theatre inside a modified flatus tube. The patients were then CT scanned for treatment planning. Measured rectal doses during treatment were compared with point dose measurements predicted by the TPS. The MOSFETs were found to require individual calibration factors. The calibration was found to drift by approximately 1% ±0.8 per 500 mV accumulated and varies with distance from source due to energy dependence. In vivo results for prostate patients found only 33% of measured doses agreed with the TPS within ±10%. For cervix cases 42% of measured doses agreed with the TPS within ±10%, however of those not agreeing variations of up to 70% were observed. One of the most limiting factors in this study was found to be the inability to prevent the MOSFET moving internally between the time of CT and treatment. Due to the many uncertainties associated with MOSFETs including calibration drift, angular dependence and the inability to know their exact position at the time of treatment, we consider them to be unsuitable for in vivo dosimetry in rectum for HDR brachytherapy.

  6. Meat and colo-rectal cancer.

    PubMed

    Hill, M J

    1999-05-01

    In early epidemiological studies of diet and cancer the stress was on the search for causal factors. Population (ecological) studies tended to show a strong correlation between meat intake, particularly red meat, and the risk of colo-rectal cancer. They also tended to show meat to be strongly inversely correlated with cancers of the stomach and oesophagus and liver. Early case-control studies tended to support the postulated role for red meat in colo-rectal carcinogenesis, although more recent case-control studies, particularly those from Europe, have tended to show no relationship. The cohort studies in general failed to detect any relationship between meat intake and colo-rectal cancer risk. The available evidence points to the intake of protective factors such as vegetables and whole-grain cereals being the main determinants of colo-rectal cancer risk, with meat intake only coincidentally related.

  7. Perioperative pain after robot-assisted versus laparoscopic rectal resection.

    PubMed

    Tolstrup, Rikke; Funder, Jonas Amstrup; Lundbech, Liselotte; Thomassen, Niels; Iversen, Lene Hjerrild

    2018-03-01

    In order to improve the surgical treatment of rectal cancer, robot-assisted laparoscopy has been introduced. The robot has gained widespread use; however, the scientific basis for treatment of rectal cancer is still unclear. The aim of this study was to investigate whether robot-assisted laparoscopic rectal resection cause less perioperative pain than standard laparoscopic resection measured by the numerical rating scale (NRS score) as well as morphine consumption. Fifty-one patients were randomized to either laparoscopic or robot-assisted rectal resection at the Department of Surgery at Aarhus University Hospital in Denmark. The intra-operative analgetic consumption was recorded prospectively and registered in patient records. Likewise all postoperative medicine administration including analgesia was recorded prospectively at the hospital medical charts. All morphine analogues were converted into equivalent oral morphine by a converter. Postoperative pain where measured by numeric rating scale (NRS) every hour at the postoperative care unit and three times a day at the ward. Opioid consumption during operation was significantly lower during robotic-assisted surgery than during laparoscopic surgery (p=0.0001). However, there were no differences in opioid consumption or NRS in the period of recovery. We found no differences in length of surgery between the two groups; however, ten patients from the laparoscopic group underwent conversion to open surgery compared to one from the robotic group (p=0.005). No significant difference between groups with respect to complications where found. In the present study, we found that patients who underwent rectal cancer resection by robotic technique needed less analgetics during surgery than patients operated laparoscopically. We did, however, not find any difference in postoperative pain score or morphine consumption postoperatively between the robotic and laparoscopic group.

  8. Rectal mucosal electrosensitivity - what is being tested?

    PubMed

    Meagher, A P; Kennedy, M L; Lubowski, D Z

    1996-01-01

    The results of rectal mucosal electrosensitivity (RME) testing have been used to support theories regarding the aetiology of both idiopathic constipation and bowel dysfunction following rectopexy. The aim of this study was to assess the validity of tests of RME. Sixty-eight patients, comprising three groups (group 1: 50 patients undergoing assessment in the Anorectal Physiology Unit, group 2: 10 patients with coloanal or ileoanal anastomosis, group 3: 8 patients with a stoma) underwent mucosal electrosensitivity testing, with the threshold stimulus required to elicit sensation being recorded. In addition the RME was measured in groups 1 and 2 when placing the electrode, mounted on a catheter with a central wire, against the anterior, posterior, right and left rectal or neorectal walls. To asses the influence on this test of loss of mucosal contact due to faeces, a further 8 cases with a normal rectum had RME performed with and without a layer of water soaked gauze around the electrode to stimulate faeces and prevent the electrode from making contact with the rectal mucosa. There was marked variance in the sensitivity of the different regions of rectal wall tested (P < 0.001). In group 1 patients the mean sensitivities were: central 36.6 mA, anterior 27.4 mA, posterior 37.9 mA, right 22.3 mA and left 25.6 mA. This circumferential variation suggests that the pelvic floor rather than rectal mucosa was being stimulated. All patients in group 2 had recordable sensitivities, and the mean sensitivity threshold was significantly higher than group 1 patients in the central (P = 0.03), right (P = 0.03) and left (P = 0.007) positions. In group 3 the sensitivity was greater within the stoma at the level of the abdominal wall muscle than intra-abdominally or subcutaneously, again suggesting an extra-colonic origin of the sensation. The sensitivity threshold was significantly greater with the electrode wrapped in gauze (P < 0.01), and loss of mucosal contact was not detected by

  9. Solitary Rectal Ulcer Syndrome: A Paediatric Case Report

    PubMed Central

    Abreu, Marlene; Azevedo Alves, Raquel; Pinto, João; Campos, Miguel; Aroso, Sofia

    2017-01-01

    Introduction Solitary rectal ulcer syndrome (SRUS) is an uncommon benign rectal disease. Mostly young adults are affected, and it is rare in paediatric populations. Clinical Case We present a 12-year-old girl with a 6-month history of tenesmus, frequent defaecation, and bloody stools with mucus. There was no previous history of constipation or other symptoms. At the first visit, physical examination and routine laboratory test results were normal. A stool examination for bacteria and parasites was negative. Colonoscopy revealed a single ulcer in the distal rectum 6 cm from the anal margin. SRUS was confirmed by biopsy. Despite conservative measures, the symptoms persisted. A defaecation proctography showed a small rectocele with no rectal mucosal prolapse. Because of its proximity to the anal sphincter, no surgical intervention was performed. Conclusion The present case illustrates how difficult the management of SRUS is. Multicentre studies are needed to establish treatment protocols for children. PMID:28848799

  10. The inability to screen exhibition swine for influenza A virus using body temperature

    PubMed Central

    Bowman, Andrew S.; Nolting, Jacqueline M.; Workman, Jeffrey D.; Cooper, Maria; Fisher, Aaron E; Marsh, Bret; Forshey, Tony

    2015-01-01

    Summary Agricultural fairs create an unconventional animal-human interface that has been associated with swine-to-human transmission of influenza A virus (IAV) in recent years. Early detection of IAV-infected pigs at agricultural fairs would allow veterinarians to better protect swine and human health during these swine exhibitions. The present study assessed the use of swine body temperature measurement, recorded by infrared and rectal thermometers, as a practical method to detect IAV-infected swine at agricultural fairs. In our first objective, infrared thermometers were used to record the body surface temperature of 1,092 pigs at the time of IAV nasal swab collection at the end of the exhibition period of 55 agricultural fairs. IAV was recovered from 212 (19.4%) pigs and the difference in mean infrared body temperature measurement of IAV-positive and negative pigs was 0.83°C. In a second objective, snout wipes were collected from 1,948 pigs immediately prior to the unloading of the animals at a single large swine exhibition. Concurrent to the snout wipe collection, owners took the rectal temperatures of his/her pigs. In this case, 47 (2.4%) pigs tested positive for IAV before they entered the swine barn. The mean rectal temperatures differed by only 0.19°C between IAV-positive and negative pigs. The low prevalence of IAV among the pigs upon entry to the fair in the second objective provides evidence that limiting intra-species spread of IAV during the fairs will likely have significant impacts on the zoonotic transmission. However, in both objectives, the high degree of similarity in the body temperature measurements between the IAV-positive and negative pigs made it impossible to set a diagnostically meaningful cut point to differentiate IAV status of the individual animals. Unfortunately, body temperature measurement cannot be used to accurately screen exhibition swine for IAV. PMID:25884907

  11. Temperature Measurement Inside Protective Headgear: Comparison With Core Temperatures and Indicators of Physiological Strain During Exercise in a Hot Environment.

    PubMed

    Mitchell, Joel B; Goldston, Kelly R; Adams, Amy N; Crisp, Kelli M; Franklin, Brian B; Kreutzer, Andreas; Montalvo, Diego X; Turner, Marcell G; Phillips, Melody D

    2015-01-01

    Non-invasive temperature monitoring with a sensor inside protective headgear may be effective in detecting temperatures that are associated with heat illness. The purpose was to establish the relationship between in-hardhat temperatures (Tih) and core temperature (Tc) as measured by rectal (Tre) and esophageal (Tes) probes. Thirty males (age 24.57 ± 4.32 yrs.) completed two trials: continuous submaximal exercise (CSE) and a series of high intensity 30-s sprints (HIE) with a one-minute rest between each. Exercise in both conditions was in a 36(°)C environment (40% RH) while wearing a standard hardhat with sensors mounted on the forehead that were monitored remotely. Exercise continued until voluntary termination or until Tc reached 39.5(°)C. Temperatures, heart rate, cardiorespiratory, and perceptual responses were monitored throughout. A physiological strain index (PSI) was calculated from Tc and HR. The final temperatures in the CSE condition were 38.77 ± 0.41, 38.90 ± 0.49 and 39.29 ± 0.58(°)C and in the HIE condition, final temperatures were 38.76 ± 0.37, 38.91 ± 0.47, and 39.19 ± 0.57 f (o)C for Tih, Tre, and Tes, respectively. The PSI in CSE was 9.62 ± 062, 9.18 ± 1.11, and 10.04 ± 1.05, and in the HIE condition 9.67 ± 068, 9.29 ± 0.99. and 9.86 ± 1.02 based on Tih, Tre and Tes, respectively. The general agreement between the Tih and other temperature measures along with the consistency as indicated by a low coefficient of variation (approx. 1%) in the recordings of the Tih sensors at the point of termination suggest that this device, or similar devices, may have application as a warning system for impending heat-related problems.

  12. Temperature measurement

    MedlinePlus

    ... this page: //medlineplus.gov/ency/article/003400.htm Temperature measurement To use the sharing features on this page, please enable JavaScript. The measurement of body temperature can help detect illness. It can also monitor ...

  13. Efficacy of Precut Endoscopic Mucosal Resection for Treatment of Rectal Neuroendocrine Tumors

    PubMed Central

    So, Hoonsub; Yoo, Su Hyun; Han, Seungbong; Kim, Gwang-un; Seo, Myeongsook; Hwang, Sung Wook; Yang, Dong-Hoon; Byeon, Jeong-Sik

    2017-01-01

    Background/Aims Endoscopic resection is the first-line treatment for rectal neuroendocrine tumors (NETs) measuring <1 cm and those between 1 and 2 cm in size. However, conventional endoscopic resection cannot achieve complete resection in all cases. We aimed to analyze clinical outcomes of precut endoscopic mucosal resection (EMR-P) used for the management of rectal NET. Methods EMR-P was used to treat rectal NET in 72 patients at a single tertiary center between 2011 and 2015. Both, circumferential precutting and EMR were performed with the same snare device in all patients. Demographics, procedural details, and histopathological features were reviewed for all cases. Results Mean size of the tumor measured endoscopically was 6.8±2.8 mm. En bloc and complete resection was achieved in 71 (98.6%) and 67 patients (93.1%), respectively. The mean time required for resection was 9.0±5.6 min. Immediate and delayed bleeding developed in six (8.3%) and 4 patients (5.6%), respectively. Immediate bleeding observed during EMR-P was associated with the risk of delayed bleeding. Conclusions Both, the en bloc and complete resection rates of EMR-P in the treatment of rectal NETs using the same snare for precutting and EMR were noted to be high. The procedure was short and safe. EMR-P may be a good treatment choice for the management of rectal NETs. PMID:29020763

  14. Optimizing Mouse Surgery with Online Rectal Temperature Monitoring and Preoperative Heat Supply. Effects on Post-Ischemic Acute Kidney Injury

    PubMed Central

    Holderied, Alexander; Anders, Hans-Joachim

    2016-01-01

    Body temperature affects outcomes of tissue injury. We hypothesized that online body core temperature recording and selective interventions help to standardize peri-interventional temperature control and the reliability of outcomes in experimental renal ischemia reperfusion injury (IRI). We recorded core temperature in up to seven mice in parallel using a Thermes USB recorder and ret-3-iso rectal probes with three different protocols. Setup A: Heating pad during ischemia time; Setup B: Heating pad from incision to wound closure; Setup C: A ventilated heating chamber before surgery and during ischemia time with surgeries performed on a heating pad. Temperature profile recording displayed significant declines upon installing anesthesia. The profile of the baseline experimental setup A revealed that <1% of the temperature readings were within the target range of 36.5 to 38.5°C. Setup B and C increased the target range readings to 34.6 ± 28.0% and 99.3 ± 1.5%, respectively. Setup C significantly increased S3 tubular necrosis, neutrophil influx, and mRNA expression of kidney injury markers. In addition, using setup C different ischemia times generated a linear correlation with acute tubular necrosis parameters at a low variability, which further correlated with the degree of kidney atrophy 5 weeks after surgery. Changing temperature control setup A to C was equivalent to 10 minutes more ischemia time. We conclude that body temperature drops quickly in mice upon initiating anesthesia. Immediate heat supply, e.g. in a ventilated heating chamber, and online core temperature monitoring can help to standardize and optimize experimental outcomes. PMID:26890071

  15. Optimizing Mouse Surgery with Online Rectal Temperature Monitoring and Preoperative Heat Supply. Effects on Post-Ischemic Acute Kidney Injury.

    PubMed

    Marschner, Julian A; Schäfer, Hannah; Holderied, Alexander; Anders, Hans-Joachim

    2016-01-01

    Body temperature affects outcomes of tissue injury. We hypothesized that online body core temperature recording and selective interventions help to standardize peri-interventional temperature control and the reliability of outcomes in experimental renal ischemia reperfusion injury (IRI). We recorded core temperature in up to seven mice in parallel using a Thermes USB recorder and ret-3-iso rectal probes with three different protocols. Setup A: Heating pad during ischemia time; Setup B: Heating pad from incision to wound closure; Setup C: A ventilated heating chamber before surgery and during ischemia time with surgeries performed on a heating pad. Temperature profile recording displayed significant declines upon installing anesthesia. The profile of the baseline experimental setup A revealed that <1% of the temperature readings were within the target range of 36.5 to 38.5°C. Setup B and C increased the target range readings to 34.6 ± 28.0% and 99.3 ± 1.5%, respectively. Setup C significantly increased S3 tubular necrosis, neutrophil influx, and mRNA expression of kidney injury markers. In addition, using setup C different ischemia times generated a linear correlation with acute tubular necrosis parameters at a low variability, which further correlated with the degree of kidney atrophy 5 weeks after surgery. Changing temperature control setup A to C was equivalent to 10 minutes more ischemia time. We conclude that body temperature drops quickly in mice upon initiating anesthesia. Immediate heat supply, e.g. in a ventilated heating chamber, and online core temperature monitoring can help to standardize and optimize experimental outcomes.

  16. Thermal reference points as an index for monitoring body temperature in marine mammals.

    PubMed

    Melero, Mar; Rodríguez-Prieto, Víctor; Rubio-García, Ana; García-Párraga, Daniel; Sánchez-Vizcaíno, José Manuel

    2015-09-04

    Monitoring body temperature is essential in veterinary care as minor variations may indicate dysfunction. Rectal temperature is widely used as a proxy for body temperature, but measuring it requires special equipment, training or restraining, and it potentially stresses animals. Infrared thermography is an alternative that reduces handling stress, is safer for technicians and works well for untrained animals. This study analysed thermal reference points in five marine mammal species: bottlenose dolphin (Tursiops truncatus); beluga whale (Delphinapterus leucas); Patagonian sea lion (Otaria flavescens); harbour seal (Phoca vitulina); and Pacific walrus (Odobenus rosmarus divergens). The thermogram analysis revealed that the internal blowhole mucosa temperature is the most reliable indicator of body temperature in cetaceans. The temperatures taken during voluntary breathing with a camera held perpendicularly were practically identical to the rectal temperature in bottlenose dolphins and were only 1 °C lower than the rectal temperature in beluga whales. In pinnipeds, eye temperature appears the best parameter for temperature control. In these animals, the average times required for temperatures to stabilise after hauling out, and the average steady-state temperature values, differed according to species: Patagonian sea lions, 10 min, 31.13 °C; harbour seals, 10 min, 32.27 °C; Pacific walruses, 5 min, 29.93 °C. The best thermographic and most stable reference points for monitoring body temperature in marine mammals are open blowhole in cetaceans and eyes in pinnipeds.

  17. Transanal Total Mesorectal Excision: A Novel Approach to Rectal Surgery

    PubMed Central

    Suwanabol, Pasithorn A.; Maykel, Justin A.

    2017-01-01

    Less invasive approaches continue to be explored and refined for diseases of the colon and rectum. The current gold standard for the surgical treatment of rectal cancer, total mesorectal excision (TME), is a technically precise yet demanding procedure with outcomes measured by both oncologic and functional outcomes (including bowel, urinary, and sexual). To date, the minimally invasive approach to rectal cancer has not yet been perfected, leaving ample opportunity for rectal surgeons to innovate. Transanal TME has recently emerged as a safe and effective technique for both benign and malignant diseases of the rectum. While widespread acceptance of this surgical approach remains tempered at this time due to lack of long-term oncologic outcome data, short-term outcomes are promising and there is great excitement surrounding the promise of this technique. PMID:28381943

  18. Infrared thermography of the udder surface of dairy cattle: characteristics, methods, and correlation with rectal temperature.

    PubMed

    Metzner, Moritz; Sauter-Louis, Carola; Seemueller, Andrea; Petzl, Wolfram; Klee, Wolfgang

    2014-01-01

    Thermograms of the caudal udder surface were taken of five healthy cows before and after inoculation of Escherichia coli into the right hind quarter. Images in clinically normal udder quarters from cows without fever (CN) were compared with those post inoculation when cows had fever (⩾ 39.5°C) and showed elevation of somatic cell counts (⩾ 400,000 cells/mL) in the inoculated quarter (CM). Using graphic software tools, different geometric analysis tools (GATs: polygons, rectangles, lines) were set within the thermographic images. The following descriptive parameters (DPs) were employed: minimum value ('min'), maximum value ('max'), range ('max-min'), and arithmetic mean ('am'). Surface temperatures in group CN were between 34.1°C ('polygons'/'min') and 37.9°C ('polygons'/'max'), and in group CM between 34.5°C ('polygons'/'min') and 40.0°C ('polygons'/'max'). The greatest differences in the temperatures between CN and CM (2.06°C) were found in 'polygons' and 'rectangles' using 'max'. The smallest coefficient of variation in triplicate determinations was found in GAT 'polygons' with DP 'max' (Tmax) (0.15%), and the relationship to the rectal body temperature (Tr) could be described by Tr=5.68+0.874*Tmax. The results show that significant changes can be displayed best using the GAT 'polygons' and the DP 'max'. These methods should be considered for automated monitoring of udder health in dairy cows. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Temperature-based death time estimation with only partially known environmental conditions.

    PubMed

    Mall, Gita; Eckl, Mona; Sinicina, Inga; Peschel, Oliver; Hubig, Michael

    2005-07-01

    The temperature-oriented death time determination is based on mathematical model curves of postmortem rectal cooling. All mathematical models require knowledge of the environmental conditions. In medico-legal practice homicide is sometimes not immediately suspected at the death scene but afterwards during external examination of the body. The environmental temperature at the death scene remains unknown or can only be roughly reconstructed. In such cases the question arises whether it is possible to estimate the time since death from rectal temperature data alone recorded over a longer time span. The present study theoretically deduces formulae which are independent of the initial and environmental temperatures and thus proves that the information needed for death time estimation is contained in the rectal temperature data. Since the environmental temperature at the death scene may differ from that during the temperature recording, an additional factor has to be used. This is that the body core is thermally well isolated from the environment and that the rectal temperature decrease after a sudden change of environmental temperature will continue for some time at a rate similar to that before the sudden change. The present study further provides a curve-fitting procedure for such scenarios. The procedure was tested in rectal cooling data of from 35 corpses using the most commonly applied model of Henssge. In all cases the time of death was exactly known. After admission to the medico-legal institute the bodies were kept at a constant environmental temperature for 12-36 h and the rectal temperatures were recorded continuously. The curve-fitting procedure led to valid estimates of the time since death in all experiments despite the unknown environmental conditions before admission to the institute. The estimation bias was investigated statistically. The 95% confidence intervals amounted to +/-4 h, which seems reasonable compared to the 95% confidence intervals of the

  20. Extracellular hyperosmolality and body temperature during physical exercise in dogs

    NASA Technical Reports Server (NTRS)

    Kozlowski, S.; Greenleaf, J. E.; Turlejska, E.; Nazar, K.

    1980-01-01

    The purpose of this study was to test the hypothesis that thermoregulation during exercise can be affected by extracellular fluid hyperosmolality without changing the plasma Na(+) concentration. The effects of preexercise venous infusions of hypertonic mannitol and NaCl solutions on rectal temperature responses were compared in dogs running at moderate intensity for 60 min on a treadmill. Plasma Na(+) concentration was increased by 12 meq after NaCl infusion, and decreased by 9 meq after mannitol infusion. Both infusions increased plasma by 15 mosmol/kg. After both infusions, rectal temperature was essentially constant during 60 min rest. However, compared with the noninfusion exercise increase in osmolality of 1.3 C, rectal temperature increased by 1.9 C after both postinfusion exercise experiments. It was concluded that inducing extracellular hyperosmolality, without elevating plasma, can induce excessive increases in rectal temperature during exericse but not at rest.

  1. In vivo trans-rectal ultrasound coupled trans-rectal near-infrared optical tomography of canine prostate bearing transmissible venereal tumor

    NASA Astrophysics Data System (ADS)

    Jiang, Zhen; Holyoak, G. Reed; Bartels, Kenneth E.; Ritchey, Jerry W.; Xu, Guan; Bunting, Charles F.; Slobodov, Gennady; Krasinski, Jerzy S.; Piao, Daqing

    2009-02-01

    In vivo trans-rectal near-infrared (NIR) optical tomography is conducted on a tumor-bearing canine prostate with the assistance of trans-rectal ultrasound (TRUS). The canine prostate tumor model is made possible by a unique round cell neoplasm of dogs, transmissible venereal tumor (TVT) that can be transferred from dog to dog regardless of histocompatibility. A characterized TVT cell line was homogenized and passed twice in subcutaneous tissue of NOD/SCID mice. Following the second passage, the tumor was recovered, homogenized and then inoculated by ultrasound guidance into the prostate gland of a healthy dog. The dog was then imaged with a combined trans-rectal NIR and TRUS imager using an integrated trans-rectal NIR/US applicator. The image was taken by NIR and US modalities concurrently, both in sagittal view. The trans-rectal NIR imager is a continuous-wave system that illuminates 7 source channels sequentially by a fiber switch to deliver sufficient light power to the relatively more absorbing prostate tissue and samples 7 detection channels simultaneously by a gated intensified high-resolution CCD camera. This work tests the feasibility of detecting prostate tumor by trans-rectal NIR optical tomography and the benefit of augmenting TRUS with trans-rectal NIR imaging.

  2. Phase I Study of Neoadjuvant Radiotherapy With 5-Fluorouracil for Rectal Cancer

    ClinicalTrials.gov

    2017-09-14

    Mucinous Adenocarcinoma of the Rectum; Recurrent Rectal Cancer; Signet Ring Adenocarcinoma of the Rectum; Rectal Adenocarcinoma; Stage IIA Rectal Cancer; Stage IIB Rectal Cancer; Stage IIC Rectal Cancer; Stage IIIA Rectal Cancer; Stage IIIB Rectal Cancer; Stage IIIC Rectal Cancer

  3. Quantitative Measures for Evaluation of Ultrasound Therapies of the Prostate

    NASA Astrophysics Data System (ADS)

    Kobelevskiy, Ilya; Burtnyk, Mathieu; Bronskill, Michael; Chopra, Rajiv

    2010-03-01

    Development of non-invasive techniques for prostate cancer treatment requires implementation of quantitative measures for evaluation of the treatment results. In this paper. we introduce measures that estimate spatial targeting accuracy and potential thermal damage to the structures surrounding the prostate. The measures were developed for the technique of treating prostate cancer with a transurethral ultrasound heating applicators guided by active MR temperature feedback. Variations of ultrasound element length and related MR imaging parameters such as MR slice thickness and update time were investigated by performing numerical simulations of the treatment on a database of ten patient prostate geometries segmented from clinical MR images. Susceptibility of each parameter configuration to uncertainty in MR temperature measurements was studied by adding noise to the temperature measurements. Gaussian noise with zero mean and standard deviation of 0, 1, 3 and 5° C was used to model different levels of uncertainty in MR temperature measurements. Results of simulations for each parameter configuration were averaged over the database of the ten prostate patient geometries studied. Results have shown that for update time of 5 seconds both 3- and 5-mm elements achieve appropriate performance for temperature uncertainty up to 3° C, while temperature uncertainty of 5° C leads to noticeable reduction in spatial accuracy and increased risk of damaging rectal wall. Ten-mm elements lacked spatial accuracy and had higher risk of damaging rectal wall compared to 3- and 5-mm elements, but were less sensitive to the level of temperature uncertainty. The effect of changing update time was studied for 5-mm elements. Simulations showed that update time had minor effects on all aspects of treatment for temperature uncertainty of 0° C and 1° C, while temperature uncertainties of 3° C and 5° C led to reduced spatial accuracy, increased potential damage to the rectal wall, and

  4. Bladder filling variation during conformal radiotherapy for rectal cancer

    NASA Astrophysics Data System (ADS)

    Sithamparam, S.; Ahmad, R.; Sabarudin, A.; Othman, Z.; Ismail, M.

    2017-05-01

    Conformal radiotherapy for rectal cancer is associated with small bowel toxicity mainly diarrhea. Treating patients with a full bladder is one of the practical solutions to reduce small bowel toxicity. Previous studies on prostate and cervix cancer patients revealed that maintaining consistent bladder volume throughout radiotherapy treatment is challenging. The aim of this study was to measure bladder volume variation throughout radiotherapy treatment. This study also measured the association between bladder volume changes and diarrhea. Twenty two rectal cancer patients were recruited prospectively. Patients were planned for treatment with full bladder following departmental bladder filling protocol and the planning bladder volume was measured during CT-simulation. During radiotherapy, the bladder volume was measured weekly using cone-beam computed tomography (CBCT) and compared to planning bladder volume. Incidence and severity of diarrhea were recorded during the weekly patient review. There was a negative time trend for bladder volume throughout five weeks treatment. The mean bladder volume decreased 18 % from 123 mL (SD 54 mL) during CT-simulation to 101 mL (SD 71 mL) on the 5th week of radiotherapy, but the decrease is not statistically significant. However, there was a large variation of bladder volume within each patient during treatment. This study showed an association between changes of bladder volume and diarrhea (P = 0.045). In conclusion bladder volume reduced throughout radiotherapy treatment for conformal radiotherapy for rectal cancer and there was a large variation of bladder volume within patients.

  5. Laparoscopic ventral rectopexy is effective for solitary rectal ulcer syndrome when associated with rectal prolapse.

    PubMed

    Evans, C; Ong, E; Jones, O M; Cunningham, C; Lindsey, I

    2014-03-01

    Solitary rectal ulcer syndrome (SRUS) is uncommon and its management is controversial. The aim of this study was to evaluate the outcome of patients with SRUS who underwent laparoscopic ventral rectopexy (LVR). A review was performed of a prospective database at the Oxford Pelvic Floor Centre to identify patients between 2004 and 2012 with a histological diagnosis of SRUS. All were initially treated conservatively and surgical treatment was indicated only for patients with significant symptoms after failed conservative management. The primary end-point was healing of the ulcer. Secondary end-points included changes in the Wexner Constipation Score and Faecal Incontinence Severity Index (FISI). Thirty-six patients with SRUS were identified (31 women), with a median age of 44 (15–81) years. The commonest symptoms were rectal bleeding (75%) and obstructed defaecation (64%). The underlying anatomical diagnosis was internal rectal prolapse (n = 20), external rectal prolapse (n = 14) or anismus (n = 2). Twenty-nine patients underwent LVR and one a stapled transanal rectal resection (STARR) procedure. Nine (30%) required a further operation, six required posterior STARR for persistent SRUS and two a per-anal stricturoplasty for a narrowing at the healed SRUS site. Healing of the SRU was seen in 27 (90%) of the 30 patients and was associated with significant improvements in Wexner and FISI scores at a 3-year follow-up. Almost all cases of SRUS in the present series were associated with rectal prolapse. LVR resulted in successful healing of the SRUS with good function in almost all patients, but a significant number will require further surgery such as STARR for persistent obstructed defaecation.

  6. A comparative study on accuracy of liquid crystal forehead, digital electronic axillary, infrared tympanic with glass-mercury rectal thermometer in infants and young children.

    PubMed

    Kongpanichkul, A; Bunjongpak, S

    2000-09-01

    This study was carried out to assess the accuracy of three devices namely, liquid crystal forehead, digital electronic axillary and infrared tympanic thermometer, using a glass-mercury rectal thermometer as the control. The subjects were two hundred children aged 0-48 months. The mean rectal temperature was 38.0 +/- 0.91 degrees C; forehead, 37.83 +/- 0.94 degrees C; tympanic, 37.77 +/- 0.95 degrees C, and axillary, 37.71 +/- 0.86 degrees C. Compared to the rectal temperature, all values were significantly lower (p < 0.05). Forehead, tympanic and axillary temperature differed from rectal temperature by at least 0.5 degrees C in 33.33 per cent, 23.5 per cent and 31.5 per cent of subjects, and at least 1 degrees C in 22 per cent, 1 per cent and 6 per cent of subjects respectively. Accuracy in detection of fever was 79 per cent for forehead, 85.5 per cent for tympanic and 84 per cent for axillary thermometry. Sensitivity of the three devices was 67-83 per cent in detection of fever and 64-77 per cent in detection of high fever. Tympanic thermometry had the best performance while forehead thermometry had the poorest. After using revised diagnostic threshold temperature by ROC curves, sensitivity of each device improved but accuracy was nearly the same. It is concluded that the three devices are not suitable as a substitute for a glass-mercury rectal thermometer in assessment of fever in infants and young children.

  7. Comparison of Esophageal, Rectal, and Gastrointestinal Temperatures During Passive Rest After Exercise in The Heat: The Influence of Hydration.

    PubMed

    Hosokawa, Yuri; Adams, William; Casa, Douglas

    2017-03-01

    Context: It is unknown how valid esophageal, rectal, and gastrointestinal temperatures (TES, TRE, and TGI) compare after exercise-induced hyperthermia under different hydration states. Objective: To examine the differences between TES, TRE, and TGI during passive rest following exercise-induced hyperthermia under 2 different hydration states: euhydrated (EU) and hypohydrated (HY). Design: Randomized crossover design. Setting: Controlled laboratory setting. Participants: 9 recreationally active male participants (mean ± SD age 24 ± 4 y, height 177.3 ± 9.9 cm, body mass 76.7 ± 11.6 kg, body fat 14.7% ± 5.8%). Intervention: Participants completed 2 trials (EU and HY) consisting of a bout of treadmill exercise (a 10-min walk at 4.8-7.2 km/h at a 5% grade followed by a 20-min jog at 8.0-12.1 km/h at a 1% grade) in a hot environment (ambient temperature 39.3 ± 1.0°C, relative humidity 37.6% ± 6.0%, wet bulb globe temperature 31.3 ± 1.5°C) followed by passive rest. Main Outcome Measures: Root-mean-squared difference (RMSD) was used to compare the variance of temperature readings at corresponding time points for TRE vs TGI, TRE vs TES, and TGI vs TES in EU and HY. RMSD values were compared using 3-way repeated-measures ANOVA. Post hoc analysis of significant main effects was done using Tukey honestly significant difference with significance set at P < .05. Results: RMSD values (°C) for all device comparisons were significantly different in EU (TRE-TGI, 0.11 ± 0.12; TRE-TES, 1.58 ± 1.01; TGI-TES, 2.04 ± 1.19) than HY (TRE-TGI, 0.22 ± 0.28; TRE-TES, 1.27 ± 0.61; TGI-TES, 1.16 ± 0.76) (P < .01). Across the 45-min bout of passive rest, there were no differences in TRE, TGI, and TES between EU and HY trials (P = .468). Conclusions: During passive rest after exercise in the heat, TRE and TGI were in good agreement when tracking body temperature, with a better agreement appearing in those maintaining a state of euhydration versus those who became hypohydrated

  8. Incidence, treatment and outcome of rectal stenosis following transanal endoscopic microsurgery.

    PubMed

    Barker, J A; Hill, J

    2011-09-01

    As an alternative to more radical abdominal surgery, transanal endoscopic microsurgery (TEM) offers a minimally invasive solution for the excision of certain rectal polyps and early-stage rectal tumours. The patient benefits of TEM as compared to radical abdominal surgery are clear; nevertheless, some drawback is possible. The aim of our study was to determine the risk factors, treatment and outcomes of rectal stenosis following TEM. We analysed a series of 354 consecutive patients who underwent TEM for benign or malignant rectal tumours between 1997 and 2009. We recorded the maximum histological diameter of the lesion, and whether the lesion was circumferential. Rectal stenosis was defined as a rectal narrowing not allowing passage of a 12 mm sigmoidoscope. Histological results with a measured specimen diameter were available in 304 of the 354 cases. There were 11 stenoses in total (3.6%), 7 stenoses due to 9 circumferential lesions (78%) and 4 due to lesions with a maximum diameter ≥ 5 cm (3.2%). Two patients presented as emergencies, and the other 9 patients reported symptoms of increased stool frequency at follow-up. Three of the stenoses were associated with recurrent disease. All stenoses were treated by a combination of endoscopic/radiological balloon dilatation or surgically with Hegar's dilators. A median of two procedures were required to treat stenoses until resolution of symptoms. Rectal stenosis following TEM excision is rare. It is predictable in patients with circumferential lesions but is rare in patients with non-circumferential lesions with a maximum diameter ≥ 5 cm. It is effectively treated with surgical or balloon dilatation. Most patients require repeated treatments.

  9. Measuring Temperature Reading

    NASA Technical Reports Server (NTRS)

    2003-01-01

    There are two requirements for taking a measurement of something. The first is a tool for taking a measurement. The second is scale for making sense of the numbers of the measurement. For example, a ruler is often used to measure short lengths. It is the tool for measurement. On the ruler are one or more number scales with equally spaced numbers. These numbers can be compared with numbers from any other ruler that is accurately set to the same scale. Measuring length is far simpler than measuring temperature. While there is evidence of tools for measuring length at various times in human history, tools and scales for measuring temperature do not appear until more recent human history. Early thermometers, called thermoscopes, first appear in the 1500's. They were crude instruments that were not at all accurate. Most did not even have a number scale associated with them. This made them useless for most practical purposes. Gabriel Fahrenheit created the first accurate thermometer in 1714, and the Fahrenheit temperature scale followed it in 1724. The thermometer s accuracy was based on its use of mercury, a silver colored substance that remains liquid over a wide range of temperatures but expands or contracts in a standard, predictable way with changes in temperature. To set the scale, Fahrenheit created the coldest temperature that he could. He mixed equal parts of ice, water, and salt, and then used this as the zero point, 0 degrees, of his scale. He intended to make 30 degrees the freezing point of water and 90 degrees the temperature of the human body, but he had to later revise these temperatures to be 32 degrees and 96 degrees. In the final version of the scale, the temperature of the human body became 98.6 degrees. 19th century thermoscope

  10. Rectal balloon use limits vaginal displacement, rectal dose, and rectal toxicity in patients receiving IMRT for postoperative gynecological malignancies.

    PubMed

    Wu, Cheng-Chia; Wuu, Yen-Ruh; Yanagihara, Theodore; Jani, Ashish; Xanthopoulos, Eric P; Tiwari, Akhil; Wright, Jason D; Burke, William M; Hou, June Y; Tergas, Ana I; Deutsch, Israel

    2018-01-01

    Pelvic radiotherapy for gynecologic malignancies traditionally used a 4-field box technique. Later trials have shown the feasibility of using intensity-modulated radiotherapy (IMRT) instead. But vaginal movement between fractions is concerning when using IMRT due to greater conformality of the isodose curves to the target and the resulting possibility of missing the target while the vagina is displaced. In this study, we showed that the use of a rectal balloon during treatment can decrease vaginal displacement, limit rectal dose, and limit acute and late toxicities. Little is known regarding the use of a rectal balloon (RB) in treating patients with IMRT in the posthysterectomy setting. We hypothesize that the use of an RB during treatment can limit rectal dose and acute and long-term toxicities, as well as decrease vaginal cuff displacement between fractions. We performed a retrospective review of patients with gynecological malignancies who received postoperative IMRT with the use of an RB from January 1, 2012 to January 1, 2015. Rectal dose constraint was examined as per Radiation Therapy Oncology Group (RTOG) 1203 and 0418. Daily cone beam computed tomography (CT) was performed, and the average (avg) displacement, avg magnitude, and avg magnitude of vector were calculated. Toxicity was reported according to RTOG acute radiation morbidity scoring criteria. Acute toxicity was defined as less than 90 days from the end of radiation treatment. Late toxicity was defined as at least 90 days after completing radiation. Twenty-eight patients with postoperative IMRT with the use of an RB were examined and 23 treatment plans were reviewed. The avg rectal V40 was 39.3% ± 9.0%. V30 was65.1% ± 10.0%. V50 was 0%. Separate cone beam computed tomography (CBCT) images (n = 663) were reviewed. The avg displacement was as follows: superior 0.4 + 2.99 mm, left 0.23 ± 4.97 mm, and anterior 0.16 ± 5.18 mm. The avg magnitude of displacement was superior

  11. Functional residual capacity and airway resistance of the rat measured with a heat- and temperature-adjusted body plethysmograph.

    PubMed

    Tajiri, Sakurako; Kondo, Tetsuri; Yamabayashi, Hajime

    2006-12-01

    The functional residual capacity (FRC) and airway resistance (R(aw)) of the rat were measured, using a newly designed body plethysmograph (BPG), the inner environment of which was maintained at body temperature and was water-vapor saturated. The subjects were anesthetized and tracheally intubated male Wistar rats (n = 15). After measuring the FRC and R(aw), we analyzed the effects of inhaled methacholine (Mch, 0-8 mg/ml) on R(aw).The determined FRC was 5.37 +/- 0.22 ml (mean +/- SE). An almost linear relationship between box pressure and respiratory flow was obtained when the difference between box-gas temperature and the rectal temperature of the rat was less than 1.0 degrees C. The R(aw) at FRC was 0.230 +/- 0.017 cm H(2)O/ml/s. It increased proportionally with increases in the Mch concentration. When the dynamic changes in R(aw) were analyzed, the R(aw) was found to progressively increase during expiration; this increase continued throughout inspiration. Thus in the rat, R(aw) is not simply a function of changes in lung volume. In conclusion, the humidity- and temperature-adjusted BPG provided an absolute and possibly dynamic value of R(aw).

  12. Physicochemical characterization of diclofenac sodium-loaded poloxamer gel as a rectal delivery system with fast absorption.

    PubMed

    Yong, Chul Soon; Sah, Hongkee; Jahng, Yurngdong; Chang, Hyeun Wook; Son, Jong-Keun; Lee, Seung Ho; Jeong, Tae Cheon; Rhee, Jong-Dal; Baek, Suk Hwan; Kim, Chong-Kook; Choi, Han-Gon

    2003-05-01

    Rectal poloxamer gel systems composed of poloxamers and bioadhesive polymers were easy to administer to the anus and were mucoadhesive to the rectal tissues without leakage after the dose. However, a poloxamer gel containing diclofenac sodium could not be developed using bioadhesive polymers, since the drug was precipitated in this preparation. To develop a poloxamer gel using sodium chloride instead of bioadhesive polymers, the physicochemical properties such as gelation temperature, gel strength, and bioadhesive force of various formulations composed of diclofenac sodium, poloxamers, and sodium chloride were investigated. Furthermore, the pharmacokinetic study of diclofenac sodium delivered by the poloxamer gel was performed. Diclofenac sodium significantly increased the gelation temperature and weakened the gel strength and bioadhesive force, while sodium chloride did the opposite. The poloxamer gels with less than 1.0% sodium chloride, in which the drug was not precipitated, were inserted into the rectum without difficulty and leakage, and were retained in the rectum of rats for at least 6 hr. Furthermore, poloxamer gel gave significantly higher initial plasma concentrations and faster Tmax of diclofenac sodium than did solid suppository, indicating that drug from poloxamer gel could be absorbed faster than that from the solid one in rats. Our results suggested that a rectal poloxamer gel system with sodium chloride and poloxamers was a more physically stable, convenient, and effective rectal dosage form for diclofenac sodium.

  13. Rectal hydrocortisone during stress in patients with adrenal insufficiency

    PubMed Central

    De Vroede, M; Beukering, R; Spit, M; Jansen, M

    1998-01-01

    OBJECTIVE—Patients with glucocorticoid deficiency need lifelong glucocorticoid replacement treatment. During acute stressful events, steroid dosage must be increased several times, which is often problematical in children. This study investigated the reliability of rectal hydrocortisone administration as an alternative to the intramuscular route.
STUDY DESIGN—Serum cortisol was assessed during stress in normal children to determine the concentration that should be achieved after rectal hydrocortisone. Subsequently, serum cortisol concentrations were measured three hours after administering a suppository containing hydrocortisone 100 mg/m2 to 57 patients with adrenocortical insufficiency. In eight patients, the time dependency of the cortisol rise after rectal administration was established.
RESULTS—In 51 previously healthy children admitted to hospital with an acute stressful condition, the mean serum cortisol concentration was 1092 nmol/l. Rectal hydrocortisone in patients with adrenocortical insufficiency resulted in a mean serum cortisol concentration of 1212 nmol/l three hours after insertion of the suppository containing hydrocortisone. In 14 of 57 children, serum cortisol was < 1000 nmol/l and in eight children it was below 600 nmol/l. One hour after administration, the mean cortisol concentration had reached 1000 nmol/l. This was sustained for more than four hours.
CONCLUSION—Rectal hydrocortisone is a safe alternative to parenteral administration in the self management of Addisonian prone conditions. However, because eight of 57 children did not achieve concentrations > 600 nmol/l, its use is recommended only after previously documenting an adequate serum cortisol concentration three hours after receiving a test dose.

 PMID:9713011

  14. Preoperative staging of rectal cancer.

    PubMed

    Yeung, Justin Mc; Ferris, Nicholas J; Lynch, A Craig; Heriot, Alexander G

    2009-10-01

    Preoperative staging is now an essential factor in the multidisciplinary management of rectal cancer because tumor stage is the strongest predictive factor for recurrence. Preoperative staging of rectal cancer can be divided into either local or distant staging. Local staging incorporates the assessment of mural wall invasion, circumferential resection margin involvement, as well as the nodal status for metastasis. Distant staging assesses for evidence of metastatic disease. The aim of this review is to consider the indications and limitations of the current preoperative imaging modalities for rectal cancer staging including clinical examination, endorectal ultrasound, magnetic resonance imaging, computed tomography and positron emission tomography-computed tomography, with respect to local and distant disease.

  15. Evaluation of Hydrogel Suppositories for Delivery of 5-Aminolevulinic Acid and Hematoporphyrin Monomethyl Ether to Rectal Tumors.

    PubMed

    Ye, Xuying; Yin, Huijuan; Lu, Yu; Zhang, Haixia; Wang, Han

    2016-10-12

    We evaluated the potential utility of hydrogels for delivery of the photosensitizing agents 5-aminolevulinic acid (ALA) and hematoporphyrin monomethyl ether (HMME) to rectal tumors. Hydrogel suppositories containing ALA or HMME were administered to the rectal cavity of BALB/c mice bearing subcutaneous tumors of SW837 rectal carcinoma cells. For comparison, ALA and HMME were also administered by three common photosensitizer delivery routes; local administration to the skin and intratumoral or intravenous injection. The concentration of ALA-induced protoporphyrin IX or HMME in the rectal wall, skin, and subcutaneous tumor was measured by fluorescence spectrophotometry, and their distribution in vertical sections of the tumor was measured using a fluorescence spectroscopy system. The concentration of ALA-induced protoporphyrin IX in the rectal wall after local administration of suppositories to the rectal cavity was 9.76-fold (1 h) and 5.8-fold (3 h) higher than in the skin after cutaneous administration. The maximal depth of ALA penetration in the tumor was ~3-6 mm at 2 h after cutaneous administration. Much lower levels of HMME were observed in the rectal wall after administration as a hydrogel suppository, and the maximal depth of tumor penetration was <2 mm after cutaneous administration. These data show that ALA more readily penetrates the mucosal barrier than the skin. Administration of ALA as an intrarectal hydrogel suppository is thus a potential delivery route for photodynamic therapy of rectal cancer.

  16. The endo-rectal probe prototype for the TOPEM project

    NASA Astrophysics Data System (ADS)

    Musico, Paolo; TOPEM Collaboration

    2016-07-01

    The TOPEM project was funded by INFN with the aim of studying the design of a TOF-PET system dedicated to prostate imaging. During last year a big effort was put into building the prototype of the endo-rectal probe from all point of view: mechanical, thermal, electrical. A dedicated integrated circuit was adopted to have the minimum dimensions: the TOFPET ASIC. The system is composed by a LYSO pixellated crystal which is seen by a 128 SiPM matrix on both surfaces: this permits Depth Of Interaction (DOI) measurement. The 4 needed ASICs are handled by a FPGA board which transmits the acquired data over an UDP connection. The external container was made using 3-D printing technology: internal channels on the external surface permit the flowing of controlled temperature (≈35 °C) water. Electronic components power is dissipated using an internal air flow kept at lower temperature (≈20 °C). The probe is MR compatible: a dedicated small antenna can be accommodated in the container. This will permit simultaneous imaging in MRI and PET systems.

  17. Laparoscopic versus open total mesorectal excision for rectal cancer.

    PubMed

    Breukink, S; Pierie, J; Wiggers, T

    2006-10-18

    disease-free survival rate, local recurrence rate, mortality, morbidity, anastomotic leakage, resection margins, or recovered lymph nodes were found. There is evidence that LTME results in less blood loss, quicker return to normal diet, less pain, less narcotic use and less immune response. It seems likely that LTME is associated with longer operative time and higher costs. No results of quality of life were reported. Based on evidence mainly from non-randomized studies, LTME appears to have clinically measurable short-term advantages in patients with primary resectable rectal cancer. The long-term impact on oncological endpoints awaits the findings from large on-going randomized trials.

  18. Rectal fluconazole for tinea capitis

    PubMed Central

    Pernica, Jeffrey M; Dayneka, Natalie; Hui, Charles PS

    2009-01-01

    The present report describes a case of tinea capitis in a boy with autistic spectrum disorder and an aversion to oral medications. He refused weekly oral fluconazole and there was a poor response to daily rectal griseofulvin. He tolerated once-weekly rectal fluconazole (10 mg/kg) well and there was an excellent clinical outcome. PMID:21037831

  19. Rectal Pre-Exposure Prophylaxis (PrEP)

    PubMed Central

    Yang, Haitao; Wang, Lin

    2014-01-01

    Rectal pre-exposure prophylaxis (PrEP) will be a critical component of HIV prevention products due to the prevalence of unprotected receptive anal intercourse among men who have sex with men and heterosexual couples. Given the biological considerations of this compartment and the complexity of HIV infection, design of a successful rectal microbicide product faces a number of challenges. Important information is being compiled to begin to address deficits in knowledge toward design of rectal PrEP products for men and women. Aspects of formulation development and preclinical and clinical evaluation of rectal products studied to date are summarized in this review. This article is based on a presentation at the "Product Development Workshop 2013: HIV and Multipurpose Prevention Technologies," held in Arlington, Virginia on February 21–22, 2013. It forms part of a special supplement to Antiviral Research. PMID:24188705

  20. SU-C-213-07: Fabrication and Testing of a 3D-Printed Small Animal Rectal Cooling Device to Evaluate Local Hypothermia as a Radioprotector During Prostate SBRT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hrycushko, B; Chopra, R; Futch, C

    Purpose: The protective effects of induced or even accidental hypothermia on the human body are widespread with several medical uses currently under active research. In vitro experiments using human cell lines have shown hypothermia provides a radioprotective effect that becomes more pronounced at large, single-fraction doses common to SBRT treatments. Relevant to prostate SBRT, this work details the fabrication and testing of a 3D-printed cooling device to facilitate the investigation of the radioprotective effect of local hypothermia on the rat rectum. Methods: A 3cm long, two-channel rectal cooling device was designed in SOLIDWORKS CAD for 3D printing. The water intakemore » nozzle is connected to a 1mm diameter brass pipe from which water flows and circulates back around to the exit nozzle. Both nozzles are connected by plastic tubing to a water chiller pump. Following leak-proof testing, fiber optic temperature probes were used to evaluate the temperature over time when placed adjacent to the cooling device within a rat rectum. MRI thermometry characterized the relative temperature distribution in concentric ROIs surrounding the probe. CBCT images from a small-animal irradiator were evaluated for imaging artifacts which could affect Monte Carlo dose calculations during treatment planning. Results: The rectal temperature adjacent to the cooling device decreased from body temperature (37°C) to 15°C in 10–20 minutes from device insertion. Rectal temperature was maintained at 15±3°C during active cooling. MRI thermometry tests revealed a steep temperature gradient with increasing distance from the cooling device, with the desired temperature range maintained within the surrounding few millimeters. Conclusion: A 3D printed rectal cooling device was fabricated for the purpose of inducing local hypothermia in rat rectums. Rectal cooling capabilities were characterized in-vivo to facilitate an investigation of the radioprotective effect of hypothermia for late

  1. Minimally invasive surgery for rectal cancer: Are we there yet?

    PubMed Central

    Champagne, Bradley J; Makhija, Rohit

    2011-01-01

    Laparoscopic colon surgery for select cancers is slowly evolving as the standard of care but minimally invasive approaches for rectal cancer have been viewed with significant skepticism. This procedure has been performed by select surgeons at specialized centers and concerns over local recurrence, sexual dysfunction and appropriate training measures have further hindered widespread acceptance. Data for laparoscopic rectal resection now supports its continued implementation and widespread usage by expeienced surgeons for select patients. The current controversies regarding technical approaches have created ambiguity amongst opinion leaders and are also addressed in this review. PMID:21412496

  2. The fibre-folate debate in colo-rectal cancer.

    PubMed

    Bingham, Sheila

    2006-02-01

    Intervention and prospective studies showing no effect of fibre in protection against colo-rectal cancer have challenged consensus recommendations that population intakes of fibre should be increased to reduce the risk of colo-rectal cancer. The European Prospective Investigation of Cancer and Nutrition (EPIC) of 519 978 individuals aged 25-70 years is the largest prospective study of diet and cancer to date worldwide. It incorporates ten different European countries in order to increase heterogeneity in dietary habits and calibration procedures to reduce measurement error. Data for 1065 reported cases of colo-rectal cancer were reported in 2003. There was a 40% reduction in risk for the highest quintile v. lowest quintile of fibre in food after calibration. It has been suggested that these effects were a result of confounding by folate and other factors. Although there are a number of hypotheses to explain why folate should be protective in colo-rectal cancer, a meta-analysis has shown that folate in food may be protective but there is no effect of total folate (i.e. food plus supplements). In a further analysis of 1826 cases in EPIC, identified in the latest follow-up, the inclusion of an additional 761 cases has confirmed the previously published results, with a strong and significant reduction in colo-rectal cancer of approximately 9% reduction in risk for each uncalibrated quintile increase in fibre (P<0.001 for linear trend) compared with an 8% reduction in the previous report, which had not been adjusted for folate. Inclusion of the other covariates (physical activity, alcohol, smoking and red and processed meat) with folate has confirmed this significant inverse association for colon cancer and strengthened the association with left-sided colon cancer (P < 0.001).

  3. Lymphogranuloma venereum as a cause of rectal strictures.

    PubMed Central

    Papagrigoriadis, S.; Rennie, J. A.

    1998-01-01

    Rectal strictures are uncommon in young patients without a history of malignancy, inflammatory bowel disease or previous surgery. Lymphogranuloma venereum of the rectum has been described as a rare cause of rectal strictures in the western world, mainly in homosexual men and in blacks. It presents with nonspecific symptoms, rectal ulcer, proctitis, anal fissures, abscesses and rectal strictures. Clinical and endoscopic findings as well as histology resemble Crohn's disease, which may be misdiagnosed. Serology is often positive for Chlamydia trachomatis but negative serology is not uncommon. We present two young black women who suffered from chronic diarrhoea, abdominal pain and weight loss. There was no previous history and investigations showed in both cases a long rectal stricture. Serology was positive in one patient. They were treated with erythromycin and azithromycin and they both underwent an anterior resection of the rectum. Postoperative histology confirmed the presence of lymphogranuloma venereum of the rectum. We conclude that rectal lymphogranuloma venereum is a rare cause of rectal strictures but surgeons should be aware of its existence and include it in the differential diagnosis of unexplained strictures in high-risk patients. Images Figure 1 Figure 2 PMID:9640444

  4. Image-guided intensity-modulated radiotherapy for prostate cancer: Dose constraints for the anterior rectal wall to minimize rectal toxicity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peterson, Jennifer L., E-mail: peterson.jennifer2@mayo.edu; Buskirk, Steven J.; Heckman, Michael G.

    2014-04-01

    Rectal adverse events (AEs) are a major concern with definitive radiotherapy (RT) treatment for prostate cancer. The anterior rectal wall is at the greatest risk of injury as it lies closest to the target volume and receives the highest dose of RT. This study evaluated the absolute volume of anterior rectal wall receiving a high dose to identify potential ideal dose constraints that can minimize rectal AEs. A total of 111 consecutive patients with Stage T1c to T3a N0 M0 prostate cancer who underwent image-guided intensity-modulated RT at our institution were included. AEs were graded according to the Common Terminologymore » Criteria for Adverse Events, version 4.0. The volume of anterior rectal wall receiving 5 to 80 Gy in 2.5-Gy increments was determined. Multivariable Cox regression models were used to identify cut points in these volumes that led to an increased risk of early and late rectal AEs. Early AEs occurred in most patients (88%); however, relatively few of them (13%) were grade ≥2. At 5 years, the cumulative incidence of late rectal AEs was 37%, with only 5% being grade ≥2. For almost all RT doses, we identified a threshold of irradiated absolute volume of anterior rectal wall above which there was at least a trend toward a significantly higher rate of AEs. Most strikingly, patients with more than 1.29, 0.73, or 0.45 cm{sup 3} of anterior rectal wall exposed to radiation doses of 67.5, 70, or 72.5 Gy, respectively, had a significantly increased risk of late AEs (relative risks [RR]: 2.18 to 2.72; p ≤ 0.041) and of grade ≥ 2 early AEs (RR: 6.36 to 6.48; p = 0.004). Our study provides evidence that definitive image-guided intensity-modulated radiotherapy (IG-IMRT) for prostate cancer is well tolerated and also identifies dose thresholds for the absolute volume of anterior rectal wall above which patients are at greater risk of early and late complications.« less

  5. Comparison of Rectal and Esophageal Sensitivity in Women With Functional Heartburn.

    PubMed

    Freede, Margaret; Leasure, A Renee; Proskin, Howard M; Hatch, Daniel; Edwards, Karethy; Pascucci, MaryAnn; Smith, Patsy R

    2016-01-01

    This study tested the primary hypothesis that there is a correlation of maximum pain threshold (MPT) in the esophagus and rectum in persons with functional heartburn. Secondary aims evaluated correlations with initial perception threshold (IPT) and pain threshold (PT). This study explored objective sensory endpoints of IPT, PT, and MPT in the esophagus and rectum of 14 females with functional heartburn to determine whether visceral hypersensitivity is generalized or organ-specific. Data on volume and pressure measurements at IPT, PT, and MPT with esophageal and rectal barostat distention were collected. The relationship of sensation and pain to volume, pressure, and compliance was analyzed. Esophageal and rectal IPT balloon volume scores were highly and significantly correlated (r = .61, p = .02). Esophageal and rectal PT balloon volume scores were highly and significantly correlated (r = .6, p = .02). Esophageal and rectal MPT balloon volume scores were not correlated (r = .35, p = .26). The correlation of visceral sensitivity in the esophagus and rectum in persons with functional heartburn supports the hypothesis that visceral sensory changes in functional gastrointestinal disorders are not organ specific.

  6. Temperature control during therapeutic moderate whole-body hypothermia for neonatal encephalopathy.

    PubMed

    Strohm, B; Azzopardi, D

    2010-09-01

    The precision of temperature control achieved in clinical practice during therapeutic hypothermia in neonates has not been described. The hourly rectal temperature recordings from 17 infants treated with servo controlled and an equal number treated with manually adjusted cooling equipment were examined. The target rectal temperature for all infants is 33.5 degrees C for 72 h. During 6 to 72 h after start of cooling, the mean (95% CI, variance) of the averaged rectal temperatures was 33.6 degrees C (95% CI 33.4 degrees C to 33.8 degrees C, 0.1 degrees C) in the manually adjusted group and 33.4 degrees C (95% CI 33.3 degrees C to 33.5 degrees C, 0.04 degrees C) in the servo controlled group (means, p=0.08; equality of variance, p=0.03). The variance was also significantly different between infant groups during 1 to 5 h after start of cooling, p=0.01, but not during rewarming. The rectal temperature can be maintained close to the target temperature with either manually adjusted or servo controlled equipment, but there is less temperature variability with the servo controlled system in use in the UK.

  7. [Anterior rectal duplication in adult patient: a case report].

    PubMed

    Rodríguez-Cabrera, J; Villanueva-Sáenz, E; Bolaños-Badillo, L E

    2009-01-01

    To report a case of rectal duplication in the adult and make a literature review. The intestinal duplications are injuries of congenital origin that can exist from the base of the tongue to the anal verge, being the most frequent site at level of terminal ileum (22%) and at the rectal level in 5% To date approximately exist 80 reports in world-wide Literature generally in the pediatric population being little frequent in the adult age. Its presentation could be tubular or cystic. The recommended treatment is the surgical resection generally in block with coloanal anastomosis. A case review of rectal duplication in the adult and the conducted treatment. The case of a patient appears with diagnose of rectal duplication with tubular type,whose main symptom was constipation and fecal impactation. In the exploration was detect double rectal lumen (anterior and posterior) that it above initiates by of the anorectal ring with fibrous ulcer of fibrinoid aspect of 3 approx cm of length x 1 cm wide, at level of the septum that separates both rectal lumina. The rectal duplication is a rare pathology in the adult nevertheless is due to suspect before the existence of alterations in the mechanics of the defecation, rectal prolapse and rectal bleeding,the election treatment is a protectomy with colonic pouch in "J" and coloanal anastomosis.

  8. Rectal Lymphogranuloma Venereum in HIV-infected Patients Can Mimic Lymphoma.

    PubMed

    Crickx, Etienne; Meignin, Véronique; Gérard, Laurence; Plantier-Colcher, Isabelle; Walker-Combrouze, Francine; Boutboul, David; Galicier, Lionel; Fieschi, Claire; Oksenhendler, Eric

    2016-01-01

    An outbreak of rectal lymphogranuloma venereum (LGV) has been reported since 2003 in men who have sex with men, most of them being infected with human immunodeficiency virus. In these patients, unusual clinical presentations such as rectal tumor or intense lymphoproliferation on rectal biopsies may lead to an erroneous diagnosis of aggressive non-Hodgkin lymphoma. Three patients were referred to our center for the management of rectal B-cell non-Hodgkin lymphoma on the basis of a rectal pathologic specimen showing intense lymphoproliferation, the very suspect of lymphoma. Because of anamnesis of anal intercourses and venereal diseases, additional study revealed that all 3 had a positive Chlamydia trachomatis polymerase chain reaction on the rectal biopsy specimen. Rectal LGV was therefore considered and successfully treated with antibiotics. We propose that all patients presenting with a suspected rectal lymphoma should have a careful anamnesis of sexual behavior and a specific detection of C. trachomatis using polymerase chain reaction analysis on biopsy specimen to rule out the possibility of rectal LGV.

  9. The Inability to Screen Exhibition Swine for Influenza A Virus Using Body Temperature.

    PubMed

    Bowman, A S; Nolting, J M; Workman, J D; Cooper, M; Fisher, A E; Marsh, B; Forshey, T

    2016-02-01

    Agricultural fairs create an unconventional animal-human interface that has been associated with swine-to-human transmission of influenza A virus (IAV) in recent years. Early detection of IAV-infected pigs at agricultural fairs would allow veterinarians to better protect swine and human health during these swine exhibitions. This study assessed the use of swine body temperature measurement, recorded by infrared and rectal thermometers, as a practical method to detect IAV-infected swine at agricultural fairs. In our first objective, infrared thermometers were used to record the body surface temperature of 1,092 pigs at the time of IAV nasal swab collection at the end of the exhibition period of 55 agricultural fairs. IAV was recovered from 212 (19.4%) pigs, and the difference in mean infrared body temperature measurement of IAV-positive and IAV-negative pigs was 0.83°C. In a second objective, snout wipes were collected from 1,948 pigs immediately prior to the unloading of the animals at a single large swine exhibition. Concurrent to the snout wipe collection, owners took the rectal temperatures of his/her pigs. In this case, 47 (2.4%) pigs tested positive for IAV before they entered the swine barn. The mean rectal temperatures differed by only 0.19°C between IAV-positive and IAV-negative pigs. The low prevalence of IAV among the pigs upon entry to the fair in the second objective provides evidence that limiting intraspecies spread of IAV during the fairs will likely have significant impacts on the zoonotic transmission. However, in both objectives, the high degree of similarity in the body temperature measurements between the IAV-positive and IAV-negative pigs made it impossible to set a diagnostically meaningful cut point to differentiate IAV status of the individual animals. Unfortunately, body temperature measurement cannot be used to accurately screen exhibition swine for IAV. © 2015 Blackwell Verlag GmbH.

  10. Bupivacaine administered intrathecally versus rectally in the management of intractable rectal cancer pain in palliative care

    PubMed Central

    Zaporowska-Stachowiak, Iwona; Kowalski, Grzegorz; Łuczak, Jacek; Kosicka, Katarzyna; Kotlinska-Lemieszek, Aleksandra; Sopata, Maciej; Główka, Franciszek

    2014-01-01

    Background Unacceptable adverse effects, contraindications to and/or ineffectiveness of World Health Organization step III “pain ladder” drugs causes needless suffering among a population of cancer patients. Successful management of severe cancer pain may require invasive treatment. However, a patient’s refusal of an invasive procedure necessitates that clinicians consider alternative options. Objective Intrathecal bupivacaine delivery as a viable treatment of intractable pain is well documented. There are no data on rectal bupivacaine use in cancer patients or in the treatment of cancer tenesmoid pain. This study aims to demonstrate that bupivacaine administered rectally could be a step in between the current treatment options for intractable cancer pain (conventional/conservative analgesia or invasive procedures), and to evaluate the effect of the mode of administration (intrathecal versus rectal) on the bupivacaine plasma concentration. Cases We present two Caucasian, elderly inpatients admitted to hospice due to intractable rectal/tenesmoid pain. The first case is a female with vulvar cancer, and malignant infiltration of the rectum/vagina. Bupivacaine was used intrathecally (0.25–0.5%, 1–2 mL every 6 hours). The second case is a female with ovarian cancer and malignant rectal infiltration. Bupivacaine was adminstered rectally (0.05–0.1%, 100 mL every 4.5–11 hours). Methods Total bupivacaine plasma concentrations were determined using the high-performance liquid chromatography-ultraviolet method. Results Effective pain control was achieved with intrathecal bupivacaine (0.077–0.154 mg·kg−1) and bupivacaine in enema (1.820 mg·kg−1). Intrathecal bupivacaine (0.5%, 2 mL) caused a drop in blood pressure; other side effects were absent in both cases. Total plasma bupivacaine concentrations following intrathecal and rectal bupivacaine application did not exceed 317.2 ng·mL−1 and 235.7 ng·mL−1, respectively. Bupivacaine elimination was

  11. Can Temperate-Water Immersion Effectively Reduce Rectal Temperature in Exertional Heat Stroke? A Critically Appraised Topic.

    PubMed

    Truxton, Tyler T; Miller, Kevin C

    2017-09-01

    Clinical Scenario: Exertional heat stroke (EHS) is a medical emergency which, if left untreated, can result in death. The standard of care for EHS patients includes confirmation of hyperthermia via rectal temperature (T rec ) and then immediate cold-water immersion (CWI). While CWI is the fastest way to reduce T rec , it may be difficult to lower and maintain water bath temperature in the recommended ranges (1.7°C-15°C [35°F-59°F]) because of limited access to ice and/or the bath being exposed to high ambient temperatures for long periods of time. Determining if T rec cooling rates are acceptable (ie, >0.08°C/min) when significantly hyperthermic humans are immersed in temperate water (ie, ≥20°C [68°F]) has applications for how EHS patients are treated in the field. Are T rec cooling rates acceptable (≥0.08°C/min) when significantly hyperthermic humans are immersed in temperate water? T rec cooling rates of hyperthermic humans immersed in temperate water (≥20°C [68°F]) ranged from 0.06°C/min to 0.19°C/min. The average T rec cooling rate for all examined studies was 0.11±0.06°C/min. Clinical Bottom Line: Temperature water immersion (TWI) provides acceptable (ie, >0.08°C/min) T rec cooling rates for hyperthermic humans post-exercise. However, CWI cooling rates are higher and should be used if feasible (eg, access to ice, shaded treatment areas). Strength of Recommendation: The majority of evidence (eg, Level 2 studies with PEDro scores ≥5) suggests TWI provides acceptable, though not ideal, T rec cooling. If possible, CWI should be used instead of TWI in EHS scenarios.

  12. Rectal bleeding after high-dose-rate brachytherapy combined with hypofractionated external-beam radiotherapy for localized prostate cancer: Impact of rectal dose in high-dose-rate brachytherapy on occurrence of grade 2 or worse rectal bleeding

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Akimoto, Tetsuo; Katoh, Hiroyuki; Kitamoto, Yoshizumi

    2006-06-01

    Purpose: To evaluate the incidence of Grade 2 or worse rectal bleeding after high-dose-rate (HDR) brachytherapy combined with hypofractionated external-beam radiotherapy (EBRT), with special emphasis on the relationship between the incidence of rectal bleeding and the rectal dose from HDR brachytherapy. Methods and Materials: The records of 100 patients who were treated by HDR brachytherapy combined with EBRT for {>=}12 months were analyzed. The fractionation schema for HDR brachytherapy was prospectively changed, and the total radiation dose for EBRT was fixed at 51 Gy. The distribution of the fractionation schema used in the patients was as follows: 5 Gy xmore » 5 in 13 patients; 7 Gy x 3 in 19 patients; and 9 Gy x 2 in 68 patients. Results: Ten patients (10%) developed Grade 2 or worse rectal bleeding. Regarding the correlation with dosimetric factors, no significant differences were found in the average percentage of the entire rectal volume receiving 30%, 50%, 80%, and 90% of the prescribed radiation dose from EBRT between those with bleeding and those without. The average percentage of the entire rectal volume receiving 10%, 30%, 50%, 80%, and 90% of the prescribed radiation dose from HDR brachytherapy in those who developed rectal bleeding was 77.9%, 28.6%, 9.0%, 1.5%, and 0.3%, respectively, and was 69.2%, 22.2%, 6.6%, 0.9%, and 0.4%, respectively, in those without bleeding. The differences in the percentages of the entire rectal volume receiving 10%, 30%, and 50% between those with and without bleeding were statistically significant. Conclusions: The rectal dose from HDR brachytherapy for patients with prostate cancer may have a significant impact on the incidence of Grade 2 or worse rectal bleeding.« less

  13. High-resolution Anorectal Manometry for Identifying Defecatory Disorders and Rectal Structural Abnormalities in Women.

    PubMed

    Prichard, David O; Lee, Taehee; Parthasarathy, Gopanandan; Fletcher, Joel G; Zinsmeister, Alan R; Bharucha, Adil E

    2017-03-01

    Contrary to conventional wisdom, the rectoanal gradient during evacuation is negative in many healthy people, undermining the utility of anorectal high-resolution manometry (HRM) for diagnosing defecatory disorders. We aimed to compare HRM and magnetic resonance imaging (MRI) for assessing rectal evacuation and structural abnormalities. We performed a retrospective analysis of 118 patients (all female; 51 with constipation, 48 with fecal incontinence, and 19 with rectal prolapse; age, 53 ± 1 years) assessed by HRM, the rectal balloon expulsion test (BET), and MRI at Mayo Clinic, Rochester, Minnesota, from February 2011 through March 2013. Thirty healthy asymptomatic women (age, 37 ± 2 years) served as controls. We used principal components analysis of HRM variables to identify rectoanal pressure patterns associated with rectal prolapse and phenotypes of patients with prolapse. Compared with patients with normal findings from the rectal BET, patients with an abnormal BET had lower median rectal pressure (36 vs 22 mm Hg, P = .002), a more negative median rectoanal gradient (-6 vs -29 mm Hg, P = .006) during evacuation, and a lower proportion of evacuation on the basis of MRI analysis (median of 40% vs 80%, P < .0001). A score derived from rectal pressure and anorectal descent during evacuation and a patulous anal canal was associated (P = .005) with large rectoceles (3 cm or larger). A principal component (PC) logistic model discriminated between patients with and without prolapse with 96% accuracy. Among patients with prolapse, there were 2 phenotypes, which were characterized by high (PC1) or low (PC2) anal pressures at rest and squeeze along with higher rectal and anal pressures (PC1) or a higher rectoanal gradient during evacuation (PC2). In a retrospective analysis of patients assessed by HRM, measurements of rectal evacuation by anorectal HRM, BET, and MRI were correlated. HRM alone and together with anorectal descent during evacuation may identify

  14. Monitoring changes in body surface temperature associated with treadmill exercise in dogs by use of infrared methodology.

    PubMed

    Rizzo, Maria; Arfuso, Francesca; Alberghina, Daniela; Giudice, Elisabetta; Gianesella, Matteo; Piccione, Giuseppe

    2017-10-01

    The aim of this study was to evaluate the influence of moderate treadmill exercise session on body surface and core temperature in dog measured by means of two infrared instruments. Ten Jack Russell Terrier/Miniature Pinscher mixed-breed dogs were subjected to 15min of walking, 10min of trotting and 10min of gallop. At every step, body surface temperature (T surface ) was measured on seven regions (neck, shoulder, ribs, flank, back, internal thigh and eye) using two different methods, a digital infrared camera (ThermaCam P25) and a non-contact infrared thermometer (Infrared Thermometer THM010-VT001). Rectal temperature (T rectal ) and blood samples were collected before (T0) and after exercise (T3). Blood samples were tested for red blood cell (RBC), hemoglobin concentration (Hb) and hematocrit (Hct). A significant effect of exercise in all body surface regions was found, as measured by both infrared methods. The temperature obtained in the eye and the thigh area were higher with respect to the other studied regions throughout the experimental period (P<0.0001). RBC, Hb, Hct and T rectal values were higher at T3 (P<0.05). Statistically significant higher temperature values measured by infrared thermometer was found in neck, shoulder, ribs, flank, back regions respect to the values obtained by digital infrared camera (P<0.0001). The results obtained in this study showed that both internal and surface temperatures are influenced by physical exercise probably due to muscle activity and changes in blood flow in dogs. Both infrared instruments used in this study have proven to be useful in detecting surface temperature variations of specific body regions, however factors including type and color of animal hair coat must be taken into account in the interpretation of data obtained by thermography methodology. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Non-invasive measurement of brain temperature with microwave radiometry: demonstration in a head phantom and clinical case.

    PubMed

    Stauffer, Paul R; Snow, Brent W; Rodrigues, Dario B; Salahi, Sara; Oliveira, Tiago R; Reudink, Doug; Maccarini, Paolo F

    2014-02-01

    This study characterizes the sensitivity and accuracy of a non-invasive microwave radiometric thermometer intended for monitoring body core temperature directly in brain to assist rapid recovery from hypothermia such as occurs during surgical procedures. To study this approach, a human head model was constructed with separate brain and scalp regions consisting of tissue equivalent liquids circulating at independent temperatures on either side of intact skull. This test setup provided differential surface/deep tissue temperatures for quantifying sensitivity to change in brain temperature independent of scalp and surrounding environment. A single band radiometer was calibrated and tested in a multilayer model of the human head with differential scalp and brain temperature. Following calibration of a 500MHz bandwidth microwave radiometer in the head model, feasibility of clinical monitoring was assessed in a pediatric patient during a 2-hour surgery. The results of phantom testing showed that calculated radiometric equivalent brain temperature agreed within 0.4°C of measured temperature when the brain phantom was lowered 10°C and returned to original temperature (37°C), while scalp was maintained constant over a 4.6-hour experiment. The intended clinical use of this system was demonstrated by monitoring brain temperature during surgery of a pediatric patient. Over the 2-hour surgery, the radiometrically measured brain temperature tracked within 1-2°C of rectal and nasopharynx temperatures, except during rapid cooldown and heatup periods when brain temperature deviated 2-4°C from slower responding core temperature surrogates. In summary, the radiometer demonstrated long term stability, accuracy and sensitivity sufficient for clinical monitoring of deep brain temperature during surgery.

  16. Effect of radiant heat on head temperature gradient in term infants.

    PubMed Central

    Gunn, A. J.; Gunn, T. R.

    1996-01-01

    AIMS: To test the hypothesis that external radiant heating might lead to significant fluctuations in superficial and core head temperatures in newborn infants. METHODS: In an observation group of 14 term infants nursed under a radiant heater, servo-controlled to the abdominal skin, changes in rectal, core head, and scalp temperatures with heater activation were examined. In a further intervention group of six infants the effect of a reflective head shield on the fluctuations of scalp temperature was also tested. RESULTS: In the observation group, when the heater had been off for 30 minutes, the rectal and scalp temperatures were 36.7 (SD 0.6) and 35.6 (0.6) degrees C, respectively, a difference of 1.2 (0.2) degrees C. After 30 minutes with the radiant heater on this fell to 0.2 (0.5) degrees C. The core head temperature, however, remained similar to the rectal temperature throughout. In the intervention group a reflective shield prevented the loss of the rectal-scalp gradient. CONCLUSION: Overhead heater activation is associated with loss of the core to scalp temperature gradient, but no change in core head temperature in term infants. The clinical relevance of this superficial heating in vulnerable infants warrants further study. PMID:8777685

  17. Correlation of Chromosomal Instability, Telomere Length and Telomere Maintenance in Microsatellite Stable Rectal Cancer: A Molecular Subclass of Rectal Cancer

    PubMed Central

    Boardman, Lisa A.; Johnson, Ruth A.; Viker, Kimberly B.; Hafner, Kari A.; Jenkins, Robert B.; Riegert-Johnson, Douglas L.; Smyrk, Thomas C.; Litzelman, Kristin; Seo, Songwon; Gangnon, Ronald E.; Engelman, Corinne D.; Rider, David N.; Vanderboom, Russell J.; Thibodeau, Stephen N.; Petersen, Gloria M.; Skinner, Halcyon G.

    2013-01-01

    Introduction Colorectal cancer (CRC) tumor DNA is characterized by chromosomal damage termed chromosomal instability (CIN) and excessively shortened telomeres. Up to 80% of CRC is microsatellite stable (MSS) and is historically considered to be chromosomally unstable (CIN+). However, tumor phenotyping depicts some MSS CRC with little or no genetic changes, thus being chromosomally stable (CIN-). MSS CIN- tumors have not been assessed for telomere attrition. Experimental Design MSS rectal cancers from patients ≤50 years old with Stage II (B2 or higher) or Stage III disease were assessed for CIN, telomere length and telomere maintenance mechanism (telomerase activation [TA]; alternative lengthening of telomeres [ALT]). Relative telomere length was measured by qPCR in somatic epithelial and cancer DNA. TA was measured with the TRAPeze assay, and tumors were evaluated for the presence of C-circles indicative of ALT. p53 mutation status was assessed in all available samples. DNA copy number changes were evaluated with Spectral Genomics aCGH. Results Tumors were classified as chromosomally stable (CIN-) and chromosomally instable (CIN+) by degree of DNA copy number changes. CIN- tumors (35%; n=6) had fewer copy number changes (<17% of their clones with DNA copy number changes) than CIN+ tumors (65%; n=13) which had high levels of copy number changes in 20% to 49% of clones. Telomere lengths were longer in CIN- compared to CIN+ tumors (p=0.0066) and in those in which telomerase was not activated (p=0.004). Tumors exhibiting activation of telomerase had shorter tumor telomeres (p=0.0040); and tended to be CIN+ (p=0.0949). Conclusions MSS rectal cancer appears to represent a heterogeneous group of tumors that may be categorized both on the basis of CIN status and telomere maintenance mechanism. MSS CIN- rectal cancers appear to have longer telomeres than those of MSS CIN+ rectal cancers and to utilize ALT rather than activation of telomerase. PMID:24278232

  18. Effect of low air velocities on thermal homeostasis and comfort during exercise at space station operational temperature and humidity

    NASA Technical Reports Server (NTRS)

    Beumer, Ronald J.

    1989-01-01

    The effectiveness of different low air velocities in maintaining thermal comfort and homeostasis during exercise at space station operational temperature and humidity was investigated. Five male subjects exercised on a treadmill for successive ten minute periods at 60, 71, and 83 percent of maximum oxygen consumption at each of four air velocities, 30, 50, 80, and 120 ft/min, at 22 C and 62 percent relative humidity. No consistent trends or statistically significant differences between air velocities were found in body weight loss, sweat accumulation, or changes in rectal, skin, and body temperatures. Occurrence of the smallest body weight loss at 120 ft/min, the largest sweat accumulation at 30 ft/min, and the smallest rise in rectal temperature and the greatest drop in skin temperature at 120 ft/min all suggested more efficient evaporative cooling at the highest velocity. Heat storage at all velocities was evidenced by increased rectal and body temperatures; skin temperatures declined or increased only slightly. Body and rectal temperature increases corresponded with increased perception of warmth and slight thermal discomfort as exercise progressed. At all air velocities, mean thermal perception never exceeded warm and mean discomfort, greatest at 30 ft/min, was categorized at worst as uncomfortable; sensation of thermal neutrality and comfort returned rapidly after cessation of exercise. Suggestions for further elucidation of the effects of low air velocities on thermal comfort and homeostasis include larger numbers of subjects, more extensive skin temperature measurements and more rigorous analysis of the data from this study.

  19. The Molecular Basis of Rectal Cancer

    PubMed Central

    Shiller, Michelle; Boostrom, Sarah

    2015-01-01

    The majority of rectal carcinomas are sporadic in nature, and relevant testing for driver mutations to guide therapy is important. A thorough family history is necessary and helpful in elucidating a potential hereditary predilection for a patient's carcinoma. The adequate diagnosis of a heritable tendency toward colorectal carcinoma alters the management of a patient disease and permits the implementation of various surveillance algorithms as preventive measures. PMID:25733974

  20. Primary Transanal Management of Rectal Atresia in a Neonate

    PubMed Central

    M, Braiek; A, Ksia; I, Krichen; S, Belhassen; K, Maazoun; S, Ben youssef; N, Kechiche; M, Mekki; A, Nouri

    2016-01-01

    Rectal atresia (RA) with a normal anus is a rare anomaly. We describe a case of rectal atresia in a newborn male presenting with an abdominal distension and failure of passing meconium. The rectal atresia was primarily operated by transanal route. PMID:27123404

  1. The effect of rectal Foley catheterization on rectal bleeding rates after transrectal ultrasound-guided prostate biopsy.

    PubMed

    Kilciler, Mete; Erdemir, Fikret; Demir, Erkan; Güven, Oğuz; Avci, Ali

    2008-09-01

    To assess whether Foley catheterization of the rectum after transrectal ultrasound (TRUS)-guided prostate biopsy decreases complication rates. Between June 2000 and September 2006, 275 consecutive patients were evaluated after undergoing TRUS-guided prostate biopsy. All procedures were performed on an outpatient basis. Patients were divided into two groups. In the first group (n = 134), a Foley catheter was inserted into the rectum and inflated to 50 cm(3) after TRUS-guided biopsy. In the second group (n = 141), catheterization was performed without balloon placement. Rectal bleeding, hematuria, hematospermia, infection, and acute urinary retention rates were compared between groups. The mean ages of the patients were 63.3 years +/- 5.6 and 62.1 years +/- 7.2 years in the Foley catheter group and control group, respectively (P = .112). Hematuria, hematospermia, infection, and rectal bleeding occurred in 31 (23.1%), 30 (22.4), nine (6.7%), and two patients (1.5%), respectively, in the Foley catheter group; and in 36 (25.5%), 36 (25.5%), 11 (7.8%), and 25 patients (17.7%), respectively, in the control group. The incidences of infection, hematuria, and hematospermia were not significantly different between groups (P > .05). In contrast, the rectal bleeding rate was significantly lower in the Foley catheter group (1.5%) than in the control group (17.7%; P = .001). Although it has no effect on other complications, TRUS-guided prostate biopsy with rectal Foley catheterization is a useful, practical method to decrease or prevent rectal bleeding.

  2. Effect of heat stress on body temperature in healthy early postpartum dairy cows.

    PubMed

    Burfeind, O; Suthar, V S; Heuwieser, W

    2012-12-01

    Measurement of body temperature is the most common method for an early diagnosis of sick cows in fresh cow protocols currently used on dairy farms. Thresholds for fever range from 39.4 °C to 39.7 °C. Several studies attempted to describe normal temperature ranges for healthy dairy cows in the early puerperium. However, the definition of a healthy cow is variable within these studies. It is challenging to determine normal temperature ranges for healthy cows because body temperature is usually included in the definition. Therefore, the objectives of this study were to identify factors that influence body temperature in healthy dairy cows early postpartum and to determine normal temperature ranges for healthy cows that calved in a moderate (temperature humidity index: 59.8 ± 3.8) and a hot period (temperature humidity index: 74.1 ± 4.4), respectively, excluding body temperature from the definition of the health status. Furthermore, the prevalence of fever was calculated for both periods separately. A subset of 17 (moderate period) and 15 cows (hot period) were used for analysis. To ensure their uterine health only cows with a serum haptoglobin concentration ≤ 1.1 g/L were included in the analysis. Therefore, body temperature could be excluded from the definition. A vaginal temperature logger that measured vaginal temperature every 10 min was inserted from Day 2 to 10 after parturition. Additionally rectal temperature was measured twice daily. Day in milk (2 to 10), period (moderate and hot), and time of day had an effect on rectal and vaginal temperature. The prevalence of fever (≥ 39.5 °C) was 7.4% and 28.1% for rectal temperature in the moderate and hot period, respectively. For vaginal temperature (07.00 to 11.00 h) it was 10% and 33%, respectively, considering the same threshold and period. This study demonstrates that body temperature in the early puerperium is influenced by several factors (day in milk, climate, time of day). Therefore, these factors

  3. A Macaque Model for Rectal Lymphogranuloma Venereum and Non-Lymphogranuloma Venereum Chlamydia trachomatis: Impact on Rectal Simian/Human Immunodeficiency Virus Acquisition.

    PubMed

    Vishwanathan, Sundaram Ajay; Aubert, Rachael D; Morris, Monica R; Zhao, Chunxia; Philips, Christi; Khalil, George M; Deyounks, Frank; Kelley, Kristen; Ritter, Jana M; Chen, C Y; Kersh, Ellen N; McNicholl, Janet M

    2017-09-01

    Sustained genital tract inflammation caused by sexually transmitted infections (STIs) is known to increase risk of vaginal human immunodeficiency virus (HIV) infections but, to our knowledge, there are no nonhuman primate studies that have evaluated its link to rectal HIV acquisition. Rhesus macaques inoculated with Chlamydia trachomatis (CT) (serovars LGV-L2 and CT-E; n = 7) or saline (n = 7) received up to 20 rectal challenges twice a week of simian/HIV immunodeficiency virus (SHIVSF162p3). SHIV viremia was determined by real-time PCR and Chlamydia infection by APTIMA Combo 2 testing. The rectal cytokine-chemokine levels were evaluated by multiplex bead assays. Rectal Chlamydia infection was maintained throughout the study. We did not observe significant differences (P = 1.0) in frequency of SHIV acquisition between the STI and control arms. It took fewer SHIV challenges to infect the STI animals although the difference was not significant (P = 0.59). There were no significant differences in peak plasma viremia between STI and control arms (P = 0.63). The association of plasma viremia with rectal shedding was significantly different by arm (P = 0.038). In the first such study in a macaque model, we did not observe an increased risk of SHIV acquisition due to rectal Chlamydia coinfection. This macaque model can be further developed and expanded to better investigate the impact of different rectal STIs on HIV acquisition.

  4. Assessing correlations between the spatial distribution of the dose to the rectal wall and late rectal toxicity after prostate radiotherapy: an analysis of data from the MRC RT01 trial (ISRCTN 47772397)

    NASA Astrophysics Data System (ADS)

    Buettner, Florian; Gulliford, Sarah L.; Webb, Steve; Sydes, Matthew R.; Dearnaley, David P.; Partridge, Mike

    2009-11-01

    Many studies have been performed to assess correlations between measures derived from dose-volume histograms and late rectal toxicities for radiotherapy of prostate cancer. The purpose of this study was to quantify correlations between measures describing the shape and location of the dose distribution and different outcomes. The dose to the rectal wall was projected on a two-dimensional map. In order to characterize the dose distribution, its centre of mass, longitudinal and lateral extent, and eccentricity were calculated at different dose levels. Furthermore, the dose-surface histogram (DSH) was determined. Correlations between these measures and seven clinically relevant rectal-toxicity endpoints were quantified by maximally selected standardized Wilcoxon rank statistics. The analysis was performed using data from the RT01 prostate radiotherapy trial. For some endpoints, the shape of the dose distribution is more strongly correlated with the outcome than simple DSHs. Rectal bleeding was most strongly correlated with the lateral extent of the dose distribution. For loose stools, the strongest correlations were found for longitudinal extent; proctitis was most strongly correlated with DSH. For the other endpoints no statistically significant correlations could be found. The strengths of the correlations between the shape of the dose distribution and outcome differed considerably between the different endpoints. Due to these significant correlations, it is desirable to use shape-based tools in order to assess the quality of a dose distribution.

  5. Limitations of temperature measurement in the aural canal with an ear mould integrated sensor.

    PubMed

    Teunissen, L P J; de Haan, A; de Koning, J J; Clairbois, H E; Daanen, H A M

    2011-09-01

    Aural canal temperature measurement using an ear mould integrated sensor (T(ac)) might be a method suited for continuous non-invasive core temperature estimation in operational settings. We studied the effect of ambient temperature, wind and high intensity exercise on T(ac) and its ability to predict esophageal (T(es)) and rectal temperatures (T(re)). Seven subjects performed a protocol of rest at 21, 10 and 30 °C, followed by exercise and recovery at 30 °C. The subjects performed the protocol twice: with and without face-wind from halfway through the 30 °C rest period. Extra auricle insulation was applied at one side. Ambient temperature changes affected T(ac) significantly, while T(es) and T(re) remained stable. Insulating the auricle reduced but did not abolish this effect. Wind had an immediate cooling effect on T(ac) independent of auricle insulation. During exercise and recovery in 30 °C, T(ac) provided acceptable group predictions of T(re) in trials without wind (bias: -0.66 ± 0.21 °C covered, -1.20 ± 0.15 °C uncovered). Bias was considerably higher with wind, but variability was similar (-1.73 ± 0.11 °C covered, -2.49 ± 0.04 °C uncovered). Individual predictions of T(es) and T(re) showed more variation, especially with wind. We conclude that T(ac) may be used for core temperature assessment of groups in warm and stable conditions.

  6. The Effects of Natural Chinese Medicine Aconite Root, Dried Ginger Rhizome, and Coptis on Rectal and Skin Temperatures at Acupuncture Points

    PubMed Central

    Li, Gang; Wang, Min; Jin, Yi-Xi; Zhang, Shu-Jing; Wu, Meng-Yao

    2017-01-01

    The 4 properties of Chinese materia medica refer to cold, hot, warm, and cool. In the present study, the effects of the Coptis, the prepared aconite root, and dried ginger rhizome were compared with regard to the rectal and skin temperature changes of the related body surface acupuncture points (Dazhui, Zhiyang, Mingmen, Zhongwan, and Shenque). The investigation aimed to explore the thermal sensitive points, which can reflect the cold and hot properties of the Chinese herbs. This study showed that the prepared aconite root and dried ginger rhizome exhibited a warming effect on the body temperature, whereas the warming sensitive points were Zhongwan, Shenque, Dazhui, and Zhiyang. Coptis exhibited both a warming and a cooling effect on the body temperature, and the cooling sensitive point was Dazhui. The concomitant effect of these three Chinese herbs on the regulation of the body temperature was reflected by Dazhui. However, there are still some limitations and one-sidedness. For instance, the cold and hot property of some herbs cannot be fully reflected through relevant acupoints on the conception and governor vessels. More detecting sites such as ears and internal organs will be selected for further exploration of Chinese herbs' cold and hot property. PMID:29259648

  7. Risk Factors Associated With Circumferential Resection Margin Positivity in Rectal Cancer: A Binational Registry Study.

    PubMed

    Warrier, Satish K; Kong, Joseph Cherng; Guerra, Glen R; Chittleborough, Timothy J; Naik, Arun; Ramsay, Robert G; Lynch, A Craig; Heriot, Alexander G

    2018-04-01

    Rectal cancer outcomes have improved with the adoption of a multidisciplinary model of care. However, there is a spectrum of quality when viewed from a national perspective, as highlighted by the Consortium for Optimizing the Treatment of Rectal Cancer data on rectal cancer care in the United States. The aim of this study was to assess and identify predictors of circumferential resection margin involvement for rectal cancer across Australasia. A retrospective study from a prospectively maintained binational colorectal cancer database was interrogated. This study is based on a binational colorectal cancer audit database. Clinical information on all consecutive resected rectal cancer cases recorded in the registry from 2007 to 2016 was retrieved, collated, and analyzed. The primary outcome measure was positive circumferential resection margin, measured as a resection margin ≤1 mm. A total of 3367 patients were included, with 261 (7.5%) having a positive circumferential resection margin. After adjusting for hospital and surgeon volume, hierarchical logistic regression analysis identified a 6-variable model encompassing the independent predictors, including urgent operation, abdominoperineal resection, open technique, low rectal cancer, T3 to T4, and N1 to N2. The accuracy of the model was 92.3%, with an receiver operating characteristic of 0.783 (p < 0.0001). The quantitative risk associated with circumferential resection margin positivity ranged from <1% (no risk factors) to 43% (6 risk factors). This study was limited by the lack of recorded long-term outcomes associated with circumferential resection margin positivity. The rate of circumferential resection margin involvement in patients undergoing rectal cancer resection in Australasia is low and is influenced by a number of factors. Risk stratification of outcome is important with the increasing demand for publicly accessible quality data. See Video Abstract at http://links.lww.com/DCR/A512.

  8. In-vivo rectal dose measurements with diodes to avoid misadministrations during intracavitary high dose rate brachytherapy for carcinoma of the cervix.

    PubMed

    Alecu, R; Alecu, M

    1999-05-01

    Our purpose in this paper is to present an in vivo dosimetry program designed both for measuring the rectal dose and for avoiding misadministrations in gynecological intracavitary implants. A device containing an energy compensated diode was specially designed for these measurements. Our calibration procedure as well as the clinical protocol is described. Measurements have been performed for 50 treatments delivered with a Fletcher Suit Delclos applicator. The calculated and in vivo measured values for the "20% reading," i.e., the dose delivered to the diode by the initial 20% of the total dwell time, agreed to within 15%.

  9. Monitoring the body temperature of cows and calves using video recordings from an infrared thermography camera.

    PubMed

    Hoffmann, Gundula; Schmidt, Mariana; Ammon, Christian; Rose-Meierhöfer, Sandra; Burfeind, Onno; Heuwieser, Wolfgang; Berg, Werner

    2013-06-01

    The aim of this study was to assess the variability of temperatures measured by a video-based infrared camera (IRC) in comparison to rectal and vaginal temperatures. The body surface temperatures of cows and calves were measured contactless at different body regions using videos from the IRC. Altogether, 22 cows and 9 calves were examined. The differences of the measured IRC temperatures among the body regions, i.e. eye (mean: 37.0 °C), back of the ear (35.6 °C), shoulder (34.9 °C) and vulva (37.2 °C), were significant (P < 0.01), except between eye and vulva (P = 0.99). The quartile ranges of the measured IRC temperatures at the 4 above mentioned regions were between 1.2 and 1.8 K. Of the investigated body regions the eye and the back of the ear proved to be suitable as practical regions for temperature monitoring. The temperatures of these 2 regions could be gained by the use of the maximum temperatures of the head and body area. Therefore, only the maximum temperatures of both areas were used for further analysis. The data analysis showed an increase for the maximum temperature measured by IRC at head and body area with an increase of rectal temperature in cows and calves. The use of infrared thermography videos has the advantage to analyze more than 1 picture per animal in a short period of time, and shows potential as a monitoring system for body temperatures in cattle.

  10. Response of glutathione S-transferase Pi (GSTP1) to neoadjuvant therapy in rectal adenocarcinoma.

    PubMed

    Bedford, M R; Anathhanam, S; Saleh, D; Hickson, A; McGregor, A K; Boyle, K; Burke, D

    2012-12-01

    The response of rectal adenocarcinoma to neoadjuvant therapy is variable. Accurate prediction of response would enable selective administration of therapy. The enzyme glutathione S-transferase Pi (GSTP1) has been shown to influence response to therapy in some solid tumours. Few data are available for rectal cancer. The GSTP1 levels in rectal adenocarcinoma and adjacent normal mucosa were quantified before and after exposure to neoadjuvant therapy. Venous blood samples and biopsies of normal rectal mucosa and tumour were prospectively obtained from patients with primary rectal cancer. Patients were stratified by exposure to neoadjuvant therapy or surgery alone. GSTP1 was quantitatively measured using an enzyme-linked immunosorbent assay. Ninety-two patients (54 men; median age 68 years) were recruited. The median GSTP1 level was significantly higher in rectal adenocarcinoma than in matched normal mucosa [6.59 μg/mg vs 4.57 μg/mg; P < 0.001]. The median tumour GSTP1 level was significantly lower in the therapy group compared with unmatched samples from the no-therapy group [4.47 μg/mg vs 7.76 μg/mg; P < 0.001]. The GSTP1 level is increased in rectal adenocarcinoma compared with adjacent normal mucosa. It decreases following neoadjuvant therapy. Future studies correlating pre-therapy GSTP1 levels with pathological response would be of interest. © 2012 The Authors. Colorectal Disease © 2012 The Association of Coloproctology of Great Britain and Ireland.

  11. Rectal sphincter pressure monitoring device.

    PubMed

    Hellbusch, L C; Nihsen, B J

    1989-05-01

    A silicone, dual cuffed catheter designed for the control of nasal hemorrhage was used for rectal sphincter pressure monitoring. Patients with lipomyelomeningocele and tethered spinal cord were monitored during their operative procedures to aid in distinguishing sacral nerve roots from other tissues. Stimulation of sacral nerve roots was done with a disposable nerve stimulator. The use of a catheter with two balloons helps to keep the outer balloon placed against the rectal sphincter.

  12. Thermosensitive In Situ Gel Based on Solid Dispersion for Rectal Delivery of Ibuprofen.

    PubMed

    Liu, Yangdan; Wang, Xin; Liu, Youping; Di, Xin

    2018-01-01

    The objective of this study was to develop a thermosensitive in situ gel based on solid dispersions (SDs) for rectal delivery of ibuprofen (IBU). Thermosensitive (poloxamer 407) and mucoadhesive (hydroxypropylmethyl cellulose E5 and sodium alginate) polymers were used to prepare the in situ gel and the sol-gel transition temperature (T sol-gel ) and gel strength were optimized. The in vitro release performance and in vivo pharmacokinetic properties of the in situ gel after their rectal administration to rabbits were investigated. Compared with the solid suppository, the cumulative release of the IBU SDs loaded in situ gel was significantly increased. The in vivo pharmacokinetics indicated that in situ gel had a higher peak plasma concentration (C max ) and area under the curve (AUC (0-∞) ) in plasma than the solid suppositories. Histopathology results showed that the IBU in situ gel given at a dose of 15 mg/kg did not produce any irritation. In conclusion, this study suggested that the in situ gel could be an effective rectal formulation for IBU.

  13. A comparison of salicylic acid levels in normal subjects after rectal versus oral dosing.

    PubMed

    Maalouf, Roger; Mosley, Mark; James Kallail, K; Kramer, Karen M; Kumar, Gaurav

    2009-02-01

    The common practice is to use 162 mg of aspirin orally in the emergency department (ED) for patients presenting with myocardial infarction. If the patient cannot take aspirin orally in the authors' facility, then 600 mg of aspirin is given rectally. However, no strong evidence exists as to whether the oral and rectal doses provide equivalent risk protection. The authors hypothesized that the salicylic acid levels for orally and rectally administered aspirin will not be similar, because of the different dosages used and the different routes of administration. The study sample consisted of healthy, nonpregnant, adult volunteers without active illness, who did not take any medication regularly. Each subject served as his or her own control to account for any confounding factors. The study was conducted on 2 days, separated by a 1-week washout period. On the first day, 162 mg of oral aspirin was chewed and swallowed. Salicylic acid levels were obtained at baseline (i.e., before taking the aspirin) and then 30, 60, and 90 minutes after dosing. The 600-mg aspirin suppository was self-administered 1 week later with a sample for laboratory measures again drawn at baseline and then 30, 60, and 90 minutes after dosing. Twenty-four subjects completed the study. The rectal suppository provided significantly more salicylic acid into the blood than the oral tablets over 90 minutes (p < 0.001). No statistical difference was noted between oral and rectal administration from baseline to 30 minutes (p > 0.05). However, mean salicylic acid levels from the rectal suppository were statistically higher than from the oral tablets from 30 to 60 minutes (p < 0.001) and from 60 to 90 minutes (p = 0.002). More than 60% of the subjects had an increasing salicylic acid level response over time to the rectal suppository. The salicylic acid level response to the oral administration was more evenly divided between those subjects whose salicylic acid levels peaked quickly and then fell or held

  14. Clinical Outcomes of Self-Expandable Metal Stents for Malignant Rectal Obstruction.

    PubMed

    Lee, Hyun Jung; Hong, Sung Pil; Cheon, Jae Hee; Kim, Tae Il; Kim, Won Ho; Park, Soo Jung

    2018-01-01

    Self-expandable metal stents are widely used to treat malignant colorectal obstruction. However, data on clinical outcomes of stent placement for rectal obstruction specifically are lacking. We aimed to investigate the clinical outcomes of self-expandable metal stents in malignant rectal obstruction in comparison with those in left colonic obstruction and to identify factors associated with clinical failure and complication. This was a retrospective study. The study was conducted at a tertiary care center. Between January 2005 and December 2013, medical charts of patients who underwent stent placement for malignant rectal or left colonic obstruction were reviewed retrospectively. Study intervention included self-expandable metal stent placement. Technical success, clinical success, and complications were measured. Technical success rates for the 2 study groups (rectum vs left colon, 93.5% vs 93.1%; p = 0.86) did not differ significantly; however, the clinical success rate was lower in patients with rectal obstruction (85.4% vs 92.1%; p = 0.02). In addition, the complication rate was higher in patients with rectal obstruction (37.4% vs 25.1%; p = 0.01). Patients with rectal obstruction showed higher rates of obstruction because of extracolonic malignancy (33.8% vs 15.8%; p < 0.001) and stent use for palliation (78.6% vs 56.3%; p < 0.001). Multivariate analysis indicated obstruction attributed to extracolonic malignancy and covered stent usage to be independent risk factors for clinical failure. Factors predictive of complications in the palliative group were total obstruction, obstruction because of extracolonic malignancy, and covered stent usage. This was a retrospective, single-center study. The efficacy and safety of stent placement for malignant rectal obstruction were comparable with those for left colonic obstruction. However, obstruction attributed to extracolonic malignancy, use of covered stents, and total obstruction negatively impacted clinical outcomes

  15. The absorption of (99m)Tc-alendronate given by rectal route in rabbits.

    PubMed

    Asikoğlu, Makbule; Ozguney, Isik; Ozcan, Ipek; Orumlu, Oya; Guneri, Tamer; Koseoğlu, Kamil; Ozkilic, Hayal

    2008-01-01

    Alendronate sodium (ALD) is a bisphosphonate medication used in the treatment and prevention of osteoporosis. Absorption of ALD as oral formulation is very poor (0.5%-1%). Its bioavailability can decrease with food effect. It has some gastrointestinal adverse effects such as gastritis, gastric ulcer, and esophagitis. The aim of this study was to develop a rectal formulation of ALD as an alternative to oral route and to investigate the absorption of it by using gamma scintigraphy. For this reason, ALD was labeled with Technetium-99m ((99m)Tc) by direct method. The radiochemical characterization of the (99m)Tc-ALD was carried out by paper chromatography, thin layer chromatography, and electrophoresis methods. The labeling efficiency of (99m)Tc-ALD was found 99% without significant changes until 6 h postlabeling at room temperature. The rectal suppositories containing (99m)Tc-ALD were prepared by fusion method using polyethylene glycol (PEG) 1500. The (99m)Tc-labeled ALD suppositories were administrated to rabbits by rectal route. Serial scintigrams over all bodies of the rabbits were obtained at different time intervals using a gamma camera. We found that the rectal absorption of (99m)Tc-ALD from suppository formulation was possible. According to our results, this formulation of ALD can be suggested for the therapy of osteoporosis as an alternative route.

  16. Variations in pelvic dimensions do not predict the risk of circumferential resection margin (CRM) involvement in rectal cancer.

    PubMed

    Salerno, G; Daniels, I R; Brown, G; Norman, A R; Moran, B J; Heald, R J

    2007-06-01

    The objective of this study was to assess the value of preoperative pelvimetry, using magnetic resonance imaging (MRI), in predicting the risk of an involved circumferential resection margin (CRM) in a group of patients with operable rectal cancer. A cohort of 186 patients from the MERCURY study was selected. These patients' histological CRM status was compared against 14 pelvimetry parameters measured from the preoperative MRI. These measurements were taken by one of the investigators (G.S.), who was blinded to the final CRM status. There was no correlation between the pelvimetry and the CRM status. However, there was a difference in the height of the rectal cancer and the positive CRM rate (p = 0.011). Of 61 patients with low rectal cancer, 10 had positive CRM at histology (16.4% with CI 8.2%-22.1%) compared with 5 of 110 patients with mid/upper rectal cancers (4.5% with CI 0.7%-8.4%). Magnetic resonance imaging can predict clear margins in most cases of rectal cancer. Circumferential resection margin positivity cannot be predicted from pelvimetry in patients with rectal cancer selected for curative surgery. The only predictive factor for a positive CRM in the patients studied was tumor height.

  17. Chloride secretagogues stimulate inositol phosphate formation in shark rectal gland tubules cultured in suspension

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ecay, T.W.; Valentich, J.D.

    1991-03-01

    Neuroendocrine activation of transepithelial chloride secretion by shark rectal gland cells is associated with increases in cellular cAMP, cGMP, and free calcium concentrations. We report here on the effects of several chloride secretagogues on inositol phosphate formation in cultured rectal gland tubules. Vasoactive intestinal peptide (VIP), atriopeptin (AP), and ionomycin increase the total inositol phosphate levels of cultured tubules, as measured by ion exchange chromatography. Forskolin, a potent chloride secretagogue, has no effect on inositol phosphate formation. The uptake of {sup 3}H-myo-inositol into phospholipids is very slow, preventing the detection of increased levels of inositol trisphosphate. However, significant increases inmore » inositol monophosphate (IP1) and inositol biphosphate (IP2) were measured. The time course of VIP- and AP-stimulated IP1 and IP2 formation is similar to the effects of these agents on the short-circuit current responses of rectal gland monolayer cultures. In addition, aluminum fluoride, an artificial activator of guanine nucleotide-binding proteins, stimulates IP1 and IP2 formation. We conclude that rectal gland cells contain VIP and AP receptors coupled to the activation of phospholipase C. Coupling may be mediated by G-proteins. Receptor-stimulated increases in inositol phospholipid metabolism is one mechanism leading to increased intracellular free calcium concentrations, an important regulatory event in the activation of transepithelial chloride secretion by shark rectal gland epithelial cells.« less

  18. A geometric model for evaluating the effects of inter-fraction rectal motion during prostate radiotherapy

    NASA Astrophysics Data System (ADS)

    Pavel-Mititean, Luciana M.; Rowbottom, Carl G.; Hector, Charlotte L.; Partridge, Mike; Bortfeld, Thomas; Schlegel, Wolfgang

    2004-06-01

    A geometric model is presented which allows calculation of the dosimetric consequences of rectal motion in prostate radiotherapy. Variations in the position of the rectum are measured by repeat CT scanning during the courses of treatment of five patients. Dose distributions are calculated by applying the same conformal treatment plan to each imaged fraction and rectal dose-surface histograms produced. The 2D model allows isotropic expansion and contraction in the plane of each CT slice. By summing the dose to specific volume elements tracked by the model, composite dose distributions are produced that explicitly include measured inter-fraction motion for each patient. These are then used to estimate effective dose-surface histograms (DSHs) for the entire treatment. Results are presented showing the magnitudes of the measured target and rectal motion and showing the effects of this motion on the integral dose to the rectum. The possibility of using such information to calculate normal tissue complication probabilities (NTCP) is demonstrated and discussed.

  19. Digital rectal exam

    MedlinePlus

    Skip navigation U.S. National Library of Medicine The navigation menu has been collapsed. Menu ... exam URL of this page: //medlineplus.gov/ency/article/007069.htm Digital rectal exam To use the sharing features ...

  20. Oral versus rectal ibuprofen in healthy volunteers.

    PubMed

    Vilenchik, Rolanda; Berkovitch, Matitiahu; Jossifoff, Azaria; Ben-Zvi, Zvi; Kozer, Eran

    2012-01-01

    Ibuprofen is a safe and effective non steroidal anti-inflammatory drug (NSAID). Ibuprofen suppositories are marketed in Europe; but data regarding pharmacokinetics of rectal vs. oral ibuprofen in humans is scarce. The objective of this study is to compare the pharmacokinetics of single-dose rectal vs. oral ibuprofen in healthy adult volunteers. Ten healthy adult male volunteers, aged 20-37 years, received in a non-blind, cross-over setting, two formulations of ibuprofen. First, a 400 mg (about 5 mg/kg) of racemic ibuprofen suppository; second (after a three week washout period) the same dosage of ibuprofen syrup. Blood samples were collected before dosing and for 12 hours after administration. Pharmacokinetics analysis was preformed. Mean peak plasma concentration (Cmax) of rectal ibuprofen was considerably lower, and the mean time to peak (Tmax) considerably longer, compared to oral ibuprofen. Absorption of rectal ibuprofen was considerably lower than oral ibuprofen, with a relative bioequivalence of 63%. Rectal ibuprofen reached therapeutic plasma concentration (>10 µg/ml) 45 minutes after dosing and remained in that range for four hours. The values of Vd/F and CL/F also differ significantly after rectal and oral administration, while no difference was found in the elimination rate constant (Kel) or half-life elimination (t1/2). Racemic ibuprofen suppository has lower bioavailability compared with ibuprofen syrup. Therapeutic plasma concentrations of ibuprofen were reached 45 minutes after dosing and remained in that range for 4 hours. Ibuprofen suppositories can contribute to the management of fever and pain when the oral route is not available.

  1. 2016 survey about temperature management during extracorporeal circulation in China.

    PubMed

    Guo, Zhen; Li, Xin

    2018-04-01

    In order to assess the current status of temperature management during cardiopulmonary bypass (CPB) in China and, thereby, implement standardized management protocols, the authors carried out a national survey about institutions performing CPB. The survey was carried out from September 2015 to February 2016 and was supported by the Chinese Society of ExtraCorporeal Circulation. A total of 114 institutions participated, accounting for 15.64% (114/729) of the total of germane Chinese institutions, whereby, 80.85% (38/47) of the institutions had an annual surgical volume of more than 1000 cases. The most common sites of temperature measurement were nasopharyngeal (NP) (99.12%) and rectal (92.98%) while oxygenator blood temperature was less popular (28%). Rectal temperature as the core temperature was chosen by 78.95% of the institutions; 92.11% of the institutions chose nasopharyngeal temperature to represent the cerebral temperature. During deep hypothermia circulatory arrest (DHCA) when there was no cerebral perfusion, 18 to 22℃ was the most common indication of circulatory arrest. However, with cerebral perfusion, more than 40% of the institutions maintained a lowest temperature of 22 to 25℃ for adult and pediatric patients. A NP temperature of 36 to 37℃ was chosen by 70.18% of the institutions while 81.79% chose a rectal temperature of 35 to 36.5℃ as the indication to wean from CPB. The majority of the institutions chose a difference of 10℃ between the water tank and core temperatures as the temperature gradient during rewarming. Auxiliary heat preservation techniques and equipment were used in 91.23% of the institutions, whereas 35.58% of them would lower the indications to wean from CPB. This survey accurately reflects the current situation of temperature management during CPB in institutions with an annual surgical volume of >500 cases, but has, hereby, failed to properly represent the institutions with a lower annual surgical volume.

  2. Application criteria for infrared ear thermometers in pediatric surgery.

    PubMed

    Saxena, A K; Topp S, S; Heinecke, A; Willital, G H

    2001-01-01

    Fever is an important and sensitive indicator of infectious diseases in children. For the past decades, measurement of body temperature in routine medical practice was limited to oral, rectal and axillary sites. In infants and children, however, temperature measurements are further limited to the rectal and axillary sites due to technical and clinical considerations. In the field of pediatric surgery, pathological and surgical conditions of the ano-rectal area often further restrict the application of conventional rectal temperature measurements. The application of tympanic temperature measurements in such pediatric surgical pathologies provides a reliable alternative to conventional rectal temperature measurements. The pediatric surgical clinico-pathological states where ear temperature measurements are the only mode of accurate temperature determination have been identified. Tympanic thermometry is well tolerated by children and predicts temperature with relative accuracy within a few seconds.

  3. Rectal forceps biopsy procedure in cystic fibrosis: technical aspects and patients perspective for clinical trials feasibility

    PubMed Central

    2013-01-01

    Background Measurements of CFTR function in rectal biopsies ex vivo have been used for diagnosis and prognosis of Cystic Fibrosis (CF) disease. Here, we aimed to evaluate this procedure regarding: i) viability of the rectal specimens obtained by biopsy forceps for ex vivo bioelectrical and biochemical laboratory analyses; and ii) overall assessment (comfort, invasiveness, pain, sedation requirement, etc.) of the rectal forceps biopsy procedure from the patients perspective to assess its feasibility as an outcome measure in clinical trials. Methods We compared three bowel preparation solutions (NaCl 0.9%, glycerol 12%, mannitol), and two biopsy forceps (standard and jumbo) in 580 rectal specimens from 132 individuals (CF and non-CF). Assessment of the overall rectal biopsy procedure (obtained by biopsy forceps) by patients was carried out by telephone surveys to 75 individuals who underwent the sigmoidoscopy procedure. Results Integrity and friability of the tissue specimens correlate with their transepithelial resistance (r = −0.438 and −0.305, respectively) and are influenced by the bowel preparation solution and biopsy forceps used, being NaCl and jumbo forceps the most compatible methods with the electrophysiological analysis. The great majority of the individuals (76%) did not report major discomfort due to the short procedure time (max 15 min) and considered it relatively painless (79%). Importantly, most (88%) accept repeating it at least for one more time and 53% for more than 4 times. Conclusions Obtaining rectal biopsies with a flexible endoscope and jumbo forceps after bowel preparation with NaCl solution is a safe procedure that can be adopted for both adults and children of any age, yielding viable specimens for CFTR bioelectrical/biochemical analyses. The procedure is well tolerated by patients, demonstrating its feasibility as an outcome measure in clinical trials. PMID:23688510

  4. Rectal forceps biopsy procedure in cystic fibrosis: technical aspects and patients perspective for clinical trials feasibility.

    PubMed

    Servidoni, Maria F; Sousa, Marisa; Vinagre, Adriana M; Cardoso, Silvia R; Ribeiro, Maria A; Meirelles, Luciana R; de Carvalho, Rita B; Kunzelmann, Karl; Ribeiro, Antônio F; Ribeiro, José D; Amaral, Margarida D

    2013-05-20

    Measurements of CFTR function in rectal biopsies ex vivo have been used for diagnosis and prognosis of Cystic Fibrosis (CF) disease. Here, we aimed to evaluate this procedure regarding: i) viability of the rectal specimens obtained by biopsy forceps for ex vivo bioelectrical and biochemical laboratory analyses; and ii) overall assessment (comfort, invasiveness, pain, sedation requirement, etc.) of the rectal forceps biopsy procedure from the patients perspective to assess its feasibility as an outcome measure in clinical trials. We compared three bowel preparation solutions (NaCl 0.9%, glycerol 12%, mannitol), and two biopsy forceps (standard and jumbo) in 580 rectal specimens from 132 individuals (CF and non-CF). Assessment of the overall rectal biopsy procedure (obtained by biopsy forceps) by patients was carried out by telephone surveys to 75 individuals who underwent the sigmoidoscopy procedure. Integrity and friability of the tissue specimens correlate with their transepithelial resistance (r = -0.438 and -0.305, respectively) and are influenced by the bowel preparation solution and biopsy forceps used, being NaCl and jumbo forceps the most compatible methods with the electrophysiological analysis. The great majority of the individuals (76%) did not report major discomfort due to the short procedure time (max 15 min) and considered it relatively painless (79%). Importantly, most (88%) accept repeating it at least for one more time and 53% for more than 4 times. Obtaining rectal biopsies with a flexible endoscope and jumbo forceps after bowel preparation with NaCl solution is a safe procedure that can be adopted for both adults and children of any age, yielding viable specimens for CFTR bioelectrical/biochemical analyses. The procedure is well tolerated by patients, demonstrating its feasibility as an outcome measure in clinical trials.

  5. Intracellular pH in Gastric and Rectal Tissue Post Cardiac Arrest

    NASA Astrophysics Data System (ADS)

    Fisher, Elaine M.; Steiner, Richard P.; LaManna, Joseph C.

    We directly measured pHi using the pH sensitive dye, neutral red. We defined pHi for rectal and gastric tissue in whole tissue and by layer under control and arrest conditions. Fifteen minutes of arrest was not sufficient time to alter the pHi at the rectal or gastric site. On initial inspection, the stomach may be more sensitive to ischemic changes than the rectum. Understanding the mechanism by which PCO2 generation is used to track clinical changes is vital to the early detection of tissue dysoxia in order to effectively treat and manage critically ill patients.

  6. The effect of temperature on amount and structure of motor variability during 2-minute maximum voluntary contraction.

    PubMed

    Brazaitis, Marius; Skurvydas, Albertas; Pukėnas, Kazimieras; Daniuseviciūtė, Laura; Mickevicienė, Dalia; Solianik, Rima

    2012-11-01

    In this study, we questioned whether local cooling of muscle or heating involving core and muscle temperatures are the main indicators for force variability. Ten volunteers performed a 2-min maximum voluntary contraction (MVC) of the knee extensors under control (CON) conditions after passive heating (HT) and cooling (CL) of the lower body. HT increased muscle and rectal temperatures, whereas CL lowered muscle temperature but did not affect rectal temperature. During 2-min MVC, peak force decreased to a lower level in HT compared with CON and CL experiments. Greater central fatigue was found in the HT experiment, and there was less in the CL experiment than in the CON experiment. Increased core and muscle temperature increased physiological tremor and the amount and structural complexity of force variability of the exercising muscles, whereas local muscle cooling decreased all force variability variables measured. Copyright © 2012 Wiley Periodicals, Inc.

  7. Effect of peritoneal lavage solution temperature on body temperature in anaesthetised cats and small dogs.

    PubMed

    Barnes, D C; Leece, E A; Trimble, T A; Demetriou, J L

    2017-05-20

    A prospective, randomised, non-blinded, clinical study to assess the effect of peritoneal lavage using warmed fluid on body temperature in anesthetised cats and dogs of less than 10 kg body mass undergoing coeliotomy. A standardised anaesthetic protocol was used. Oesophageal and rectal temperatures were measured at various time points. At the end of surgery, group 1 patients (n=10) were lavaged with 200 ml/kg sterile isotonic saline at 34±1°C and group 2 (n=10) at 40±1°C. Groups were similar with respect to age, mass, body condition and surgical incision length. Duration of anaesthesia, surgical procedures and peritoneal lavage was similar between groups. Linear regression showed no significant change in oesophageal temperature during the lavage period for group 1 (P=0.64), but a significant increase for group 2 patients (P<0.0001), with mean temperature changes of -0.5°C (from (36.3°C to 35.9°C) and +0.9°C (from 35.4°C to 36.3°C), respectively. Similar results were found for rectal temperature, with mean changes of -0.5°C and +0.8°C (P=0.922 and 0.045), respectively. The use of isotonic crystalloid solution for peritoneal lavage at a temperature of 40±1°C significantly warms small animal patients, when applied in a clinical setting, compared with lavage solution at 34±1°C. British Veterinary Association.

  8. Bioavailabilities of rectal and oral methadone in healthy subjects

    PubMed Central

    Dale, Ola; Sheffels, Pamela; Kharasch, Evan D

    2004-01-01

    Aims Rectal administration of methadone may be an alternative to intravenous and oral dosing in cancer pain, but the bioavailability of the rectal route is not known. The aim of this study was to compare the absolute rectal bioavailability of methadone with its oral bioavailability in healthy humans. Methods Seven healthy subjects (six males, one female, aged 20–39 years) received 10 mg d5-methadone-HCl rectally (5 ml in 20% glycofurol) together with either d0-methadone intravenously (5 mg) or orally (10 mg) on two separate occasions. Blood samples for the LC-MS analyses of methadone and it's metabolite EDDP were drawn for up to 96 h. Noninvasive infrared pupillometry was peformed at the same time as blood sampling. Results The mean absolute rectal bioavalability of methadone was 0.76 (0.7, 0.81), compared to 0.86 (0.75, 0.97) for oral administration (mean (95% CI)). Rectal absorption of methadone was more rapid than after oral dosing with Tmax values of 1.4 (0.9, 1.8) vs. 2.8 (1.6, 4.0) h. The extent of formation of the metabolite EDDP did not differ between routes of administration. Single doses of methadone had a duration of action of at least 10 h and were well tolerated. Conclusions Rectal administration of methadone results in rapid absorption, a high bioavailability and long duration of action. No evidence of presystemic elimination was seen. Rectal methadone has characteristics that make it a potential alternative to intravenous and oral administration, particularly in cancer pain and palliative care. PMID:15255797

  9. Rectal swab screening assays of public health importance in molecular diagnostics: Sample adequacy control.

    PubMed

    Glisovic, Sanja; Eintracht, Shaun; Longtin, Yves; Oughton, Matthew; Brukner, Ivan

    Rectal swabs are routinely used by public health authorities to screen for multi-drug resistant enteric bacteria including vancomycin-resistant enterococci (VRE) and carbapenem-resistant enterobacteriaceae (CRE). Screening sensitivity can be influenced by the quality of the swabbing, whether performed by the patient (self-swabbing) or a healthcare practitioner. One common exclusion criterion for rectal swabs is absence of "visible soiling" from fecal matter. In our institution, this criterion excludes almost 10% of rectal swabs received in the microbiology laboratory. Furthermore, over 30% of patients in whom rectal swabs are cancelled will not be re-screened within the next 48h, resulting in delays in removing infection prevention measures. We describe two quantitative polymerase chain reaction (qPCR)-based assays, human RNAse P and eubacterial 16S rDNA, which might serve as suitable controls for sampling adequacy. However, lower amounts of amplifiable human DNA make the 16s rDNA assay a better candidate for sample adequacy control. Copyright © 2017. Published by Elsevier Ltd.

  10. Evaluation of Disinfection Techniques for, and Their Effects on, Rectal Thermocouple Catheters1

    PubMed Central

    Maher, J. T.; Rogers, M. R.; Peterson, D. W.

    1961-01-01

    The antibacterial activities of an iodophor (Wescodyne G), a quaternary ammonium compound (Roccal), and an iodine tincture as agents for the cold disinfection of rectal catheters contaminated in vitro were determined. Following thorough cleaning with an alcoholic solution of soft soap, each of the three disinfectants tested showed satisfactory results (100% kill) in 5 min against the enteric test bacteria (Escherichia coli and Salmonella typhosa) as well as a test species of the genus Pseudomonas, among the bacteria most resistant to surface-active agents. An aqueous solution of Wescodyne G containing 75 ppm available iodine was used both as a wiping solution and for subsequent disinfection of rectal catheters contaminated in vivo. Total bacterial destruction was found to follow a 60-min soak preceded by the wiping procedure. Rectal catheters subjected to prolonged immersion in each of the test disinfectants were found to be essentially unaffected, retaining their initial calibrations within a permissible tolerance. Neither Roccal nor Wescodyne G solutions were found to measurably attack bare thermocouples. Alcoholic iodine 0.5% did, however, exert a deteriorating effect on bare thermocouples in a short time, as measured by change in resistance characteristics. The results of this study have led to the recommendation that Wescodyne G containing 75 ppm available iodine be used in standing operating procedures for the initial cleaning and subsequent disinfection of rectal thermocouple catheters. Images Fig. 1 PMID:13765378

  11. Manometric characterization of rectal dysfunction following radical hysterectomy.

    PubMed

    Barnes, W; Waggoner, S; Delgado, G; Maher, K; Potkul, R; Barter, J; Benjamin, S

    1991-08-01

    Bladder dysfunction thought to be due to partial denervation has been described following radical hysterectomy. Some patients experience acute and chronic rectal dysfunction characterized by difficulty with defecation and loss of defecatory urge. To define this abnormality, anorectal pressure profiles were examined in 15 patients with Stage I carcinoma of the cervix before and after radical hysterectomy. Profiles were done using standard anorectal manometry with a water-infused system. In all patients preoperative manometric profiles were normal; postoperative studies were abnormal in all patients. Features seen include altered relaxation of the internal sphincter, increased distension needed to trigger relaxation, and decreased rectal sensation; external sphincters and resting internal sphincters were unchanged. Postoperatively, 12 patients reported problems with rectal function. A physiologic defect is definable in patients undergoing radical hysterectomy; this suggests disruption of the spinal reflex arcs controlling rectal emptying. These physiologic abnormalities correlate with the clinical symptomatology experienced by some patients. Continuing definition and evaluation of management options in this situation should be useful in developing effective therapy for rectal dysfunction following radical hysterectomy.

  12. Atrial natriuretic peptide stimulates salt secretion by shark rectal gland by releasing VIP

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Silva, P.; Stoff, J.S.; Solomon, R.J.

    1987-01-01

    Salt secretion by the isolated perfused rectal gland of the spiny dogfish shark, Squalus acanthias, is stimulated by synthetic rat atrial natriuretic peptide (ANP II) as well as extracts of shark heart, but not by 8-bromo-cyclic guanosine 5'-monophosphate. Cardiac peptides have no effect on isolated rectal gland cells or perfused tubules, suggesting that stimulation requires an intact gland. The stimulation of secretion by ANP II is eliminated by maneuvers that block neurotransmitter release. Cardiac peptides stimulate the release of vasoactive intestinal peptide (VIP), known to be present in rectal glands nerves, into the venous effluent of perfused glands in parallelmore » with their stimulation of salt secretion, but the release of VIP induced by ANP II is prevented by perfusion with procaine. VIP was measured by radioimmunoassay. Cardiac peptides thus appear to regulate rectal gland secretion by releasing VIP from neural stores within the gland. It is possible that other physiological effects of these hormones might be explained by an action to enhanced local release of neurotransmitters.« less

  13. Do heat and moisture exchangers in the anaesthesia breathing circuit preserve body temperature in dogs undergoing anaesthesia for magnetic resonance imaging?

    PubMed

    Khenissi, Latifa; Covey-Crump, Gwen; Knowles, Toby G; Murrell, Joanna

    2017-05-01

    To investigate whether the use of a heat and moisture exchanger (HME) preserves body temperature in dogs weighing <10 kg anaesthetised for magnetic resonance imaging (MRI). Prospective, randomised, clinical trial. Thirty-one client-owned dogs. Dogs were assigned randomly to a treatment group [HME (n = 16) or no HME (n = 15)]. Dogs were pseudorandomised according to the premedication they were administered, either dexmedetomidine or no dexmedetomidine. Induction agents were not standardised. General anaesthesia was maintained with isoflurane vaporised in 100% oxygen delivered using a T-piece and a fresh gas flow of 600 mL kg -1 minute -1 . Rectal temperature was measured before premedication (T1), after induction (T2), before moving to the MRI unit (T3) and at the end of the MRI scan (T4). Ambient temperatures were measured in the induction room, outside and inside the MRI unit. Data were analysed using a general linear model with T4 as the outcome variable. Linear correlations were performed between T1, T2, T3 and T4, and variables that predicted T4 were investigated. Sex, age and body mass were not significantly different between groups. There were no significant differences in rectal temperature between groups at any time point (group with HME at the end of MRI = 36.3 ± 1.1 °C; group with no HME at the end of MRI = 36.2 ± 1.4 °C) but at the end of the MRI, dogs administered dexmedetomidine (36.6 ± 0.7 °C) had a higher rectal temperature compared with dogs not administered dexmedetomidine (35.9 ± 1.6 °C) for premedication. Rectal temperature varied directly with ambient temperature in MRI scanning room and inversely with anaesthetic duration. Using an HME did not alter body temperature in dogs weighing <10 kg undergoing an MRI, but including dexmedetomidine in the premedication regimen seemed to preserve the body temperature during anaesthesia. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  14. Robotically performed total mesorectal excision for rectal cancer.

    PubMed

    Alecu, L; Stănciulea, O; Poesina, D; Tomulescu, V; Vasilescu, C; Popescu, I

    2015-01-01

    Rectal cancer is an important health problem, due to the increasing number of new cases and the quality of life issues brought forth by surgical treatment in these patients. The aim of the study was to analyse the results of robotic surgery in the treatment of lower and middle rectal cancer,locations in which TME is performed. Patients diagnosed with and operated on for rectal cancer by the means of robotic surgery between 2008-2012 at the Fundeni Clinical Institute were retrospectively analysed. A number of 117 patients with rectal cancer were operated on by robotic surgery, of which 79 (67.52%) were submitted to total mesorectal excision (TME). The most frequently performed surgery was low anterior resection, followed by rectal amputation through abdominoperineal approach.Anastomosis fistula was observed in 9 (11.39%) patients. Local recurrence was encountered in 2 (2.53%) of the robotically performed surgeries. 1. Robotically assisted total mesorectal excision is feasible, safe and can be performed with a small number of complications and a low local recurrence rate; 2. The main advantages are oncological safety and quality of life; 3.Conversion to open surgery is rarely encountered; 4. Protection loop ileostomy existence allows avoiding reintervention in case anastomotic fistula occurs in patients with low anterior resection. 5. Robotic surgery may become gold standard in the surgical treatment of rectal cancer. Celsius.

  15. [A Case of Rectal Syphilis Incidentally Found at Regular Medical Check-up].

    PubMed

    You, Ji Hong; Cho, Ki Won; Cha, Yoon Jin; Park, Hyo Jin

    2016-10-25

    Syphilis is a rare disease in the rectum. It is difficult to diagnose because the characteristics of the rectal syphilis rectal lesion are highly varied. The endoscopic findings of rectal syphilis are proctitis, ulcers, and masses. If rectal syphilis is suspected to be the cause for rectal lesions, it is important for physicians to consider the sexual history and sexual orientation of the patient. We report a case of incidental rectal syphilis in a 41-year-old man diagnosed during a regular medical check-up.

  16. Rectal Cancer Treatment (PDQ®)—Health Professional Version

    Cancer.gov

    Rectal cancer treatment options include surgery, radiation therapy, chemoradiation, chemotherapy, targeted therapy, ablation, and surveillance. Get detailed information about the treatment of newly diagnosed and recurrent rectal cancer in this summary for clinicians.

  17. Rectal culture (image)

    MedlinePlus

    A rectal culture test is performed by inserting a cotton swab in the rectum. The swab is rotated gently, and withdrawn. A smear of the swab is placed in culture media to encourage the growth of microorganisms. The ...

  18. Functional brain imaging in irritable bowel syndrome with rectal balloon-distention by using fMRI.

    PubMed

    Yuan, Yao-Zong; Tao, Ran-Jun; Xu, Bin; Sun, Jing; Chen, Ke-Min; Miao, Fei; Zhang, Zhong-Wei; Xu, Jia-Yu

    2003-06-01

    Irritable bowel syndrome (IBS) is characterized by abdominal pain and changes in stool habits. Visceral hypersensitivity is a key factor in the pathophysiology of IBS. The aim of this study was to examine the effect of rectal balloon-distention stimulus by blood oxygenation level-dependent functional magnetic resonance imaging (BOLD-fMRI) in visceral pain center and to compare the distribution, extent, and intensity of activated areas between IBS patients and normal controls. Twenty-six patients with IBS and eleven normal controls were tested for rectal sensation, and the subjective pain intensity at 90 ml and 120 ml rectal balloon-distention was reported by using Visual Analogue Scale. Then, BOLD-fMRI was performed at 30 ml, 60 ml, 90 ml, and 120 ml rectal balloon-distention in all subjects. Rectal distention stimulation increased the activity of anterior cingulate cortex (35/37), insular cortex (37/37), prefrontal cortex (37/37), and thalamus (35/37) in most cases. At 120 ml of rectal balloon-distention, the activation area and percentage change in MR signal intensity of the regions of interest (ROI) at IC, PFC, and THAL were significantly greater in patients with IBS than that in controls. Score of pain sensation at 90 ml and 120 ml rectal balloon-distention was significantly higher in patients with IBS than that in controls. Using fMRI, some patients with IBS can be detected having visceral hypersensitivity in response to painful rectal balloon-distention. fMRI is an objective brain imaging technique to measure the change in regional cerebral activation more precisely. In this study, IC and PFC of the IBS patients were the major loci of the CNS processing of visceral perception.

  19. How to identify rectal sub-regions likely involved in rectal bleeding in prostate cancer radiotherapy

    NASA Astrophysics Data System (ADS)

    Dréan, G.; Acosta, O.; Ospina, J. D.; Voisin, C.; Rigaud, B.; Simon, A.; Haigron, P.; de Crevoisier, R.

    2013-11-01

    Nowadays, the de nition of patient-speci c constraints in prostate cancer radiotherapy planning are solely based on dose-volume histogram (DVH) parameters. Nevertheless those DVH models lack of spatial accuracy since they do not use the complete 3D information of the dose distribution. The goal of the study was to propose an automatic work ow to de ne patient-speci c rectal sub-regions (RSR) involved in rectal bleeding (RB) in case of prostate cancer radiotherapy. A multi-atlas database spanning the large rectal shape variability was built from a population of 116 individuals. Non-rigid registration followed by voxel-wise statistical analysis on those templates allowed nding RSR likely correlated with RB (from a learning cohort of 63 patients). To de ne patient-speci c RSR, weighted atlas-based segmentation with a vote was then applied to 30 test patients. Results show the potentiality of the method to be used for patient-speci c planning of intensity modulated radiotherapy (IMRT).

  20. Immediate postoperative complications of combined penetrating rectal and bladder injuries.

    PubMed

    Crispen, Paul L; Kansas, Bryan T; Pieri, Paola G; Fisher, Carol; Gaughan, John P; Pathak, Abhijit S; Mydlo, Jack H; Goldberg, Amy J

    2007-02-01

    Combined penetrating trauma involving the rectum and bladder has been associated with increased postoperative morbidity. Specific complications resulting from these injuries include colovesical fistula, urinoma, and abscess formation. A retrospective review of Temple University Hospital trauma database was performed. Patients were categorized by having an isolated rectal (n = 29), isolated bladder (n = 16), or combined injury (n = 24). Records were reviewed for sex, age, site of injury, location of rectal and bladder injuries, operative intervention, fistula formation, urinoma formation, abscess formation, time to urinary catheter removal, length of intensive care unit stay, and length of hospital stay. Patient sex and age did not differ significantly between groups, nor was there a significant difference in location of rectal injury between groups. Presacral drainage was utilized in all patients with extraperitoneal injuries. Fecal diversion was performed in all patients, except two with intraperitoneal rectal injuries. Omental flap interposition between rectal and bladder injuries was utilized in one patient. No significant difference was noted in immediate postoperative complications between groups including fistula, urinoma, and abscess formation. However, all cases of colovesical fistula (n = 2) and urinoma (n = 2) formation were noted in those patients with rectal and posterior bladder injuries. Combined rectal and bladder injuries were not associated with an increase in immediate postoperative complications compared with isolated rectal and bladder injuries. However, postoperative fistula and urinoma formation occurred only in patients with a combined rectal and posterior bladder injury. Consequently, these patients may benefit from omental flap interposition between injuries to decrease fistula and urinoma formation.

  1. Acute normobaric hypoxia reduces body temperature in humans.

    PubMed

    DiPasquale, Dana M; Kolkhorst, Fred W; Buono, Michael J

    2015-03-01

    Anapyrexia is the regulated decrease in body temperature during acute exposure to hypoxia. This study examined resting rectal temperature (Trec) in adult humans during acute normobaric hypoxia (NH). Ten subjects breathed air consisting of 21% (NN), 14% (NH14), and 12% oxygen (NH12) for 30 min each in thermoneutral conditions while Trec and blood oxygen saturation (Spo2) were measured. Linear regression indicated that Spo2 was progressively lower in NH14 (p=0.0001) and NH12 (p=0.0001) compared to NN, and that Spo2 in NH14 was different than NH12 (p=0.00001). Trec was progressively lower during NH14 (p=0.014) and in NH12 (p=0.0001) compared to NN. The difference in Trec between NH14 and NH12 was also significant (p=0.0287). Spo2 was a significant predictor of Trec such that for every 1% decrease in Spo2, Trec decreased by 0.15°C (p=0.0001). The present study confirmed that, similar to many other species, human adults respond to acute hypoxia exposure by lowering rectal temperature.

  2. Novel dual-reverse thermosensitive solid lipid nanoparticle-loaded hydrogel for rectal administration of flurbiprofen with improved bioavailability and reduced initial burst effect.

    PubMed

    Din, Fakhar Ud; Mustapha, Omer; Kim, Dong Wuk; Rashid, Rehmana; Park, Jong Hyuck; Choi, Ju Yeon; Ku, Sae Kwang; Yong, Chul Soon; Kim, Jong Oh; Choi, Han-Gon

    2015-08-01

    The purpose of this study was to develop novel solid lipid nanoparticle (SLN)-loaded dual-reverse thermosensitive hydrogel (DRTH) for rectal administration of flurbiprofen with improved bioavailability and reduced initial burst effect. The flurbiprofen-loaded SLNs were prepared by hot homogenisation technique, after optimising the amounts of lipid mixture (tricaprin and triethanolamine in 8:2 weight ratio), drug and surfactant. The flurbiprofen-loaded thermosensitive SLN composed of drug, lipid mixture and surfactant at a weight ratio of 10/15/1.3 was a solid at room temperature, and changed to liquid form at physiological temperature due to its melting point of about 32°C. This SLN gave the mean particle size of about 190nm and entrapment efficiency of around 90%. The DRTHs were prepared by adding this flurbiprofen-loaded thermosensitive SLN in various poloxamer solutions. Their rheological characterisation, release and stability were investigated while a morphological and pharmacokinetic study was performed after its rectal administration to rats compared with the drug and hydrogel. Poloxamer 188 and SLN decreased the gelation temperature and gelation time, but increased the viscosity at 25°C, gel strength and mucoadhesive force of DRTHs. In particular, the DRTH composed of [SLN/P 407/P 188 (10%/15%/25%)] with the gelation temperature of about 35°C existed as liquid at room temperature, but gelled at 30-36°C, leading to opposite reversible property of SLN. Thus, it was easy to administer rectally, and it gelled rapidly inside the body. This DRTH gave a significantly increased dissolution rate of the drug as compared to the flurbiprofen, but significantly retarded as compared to the hydrogel, including the initial dissolution rate. Moreover, this DRTH gave significantly higher plasma concentration and 7.5-fold AUC values compared to the drug, and lower initial plasma concentration and Cmax value compared to the hydrogel due to reduced initial burst effect. No

  3. High-temperature-measuring device

    DOEpatents

    Not Available

    1981-01-27

    A temperature measuring device for very high design temperatures (to 2000/sup 0/C) is described. The device comprises a homogenous base structure preferably in the form of a sphere or cylinder. The base structure contains a large number of individual walled cells. The base structure has a decreasing coefficient of elasticity within the temperature range being monitored. A predetermined quantity of inert gas is confined within each cell. The cells are dimensonally stable at the normal working temperature of the device. Increases in gaseous pressure within the cells will permanently deform the cell walls at temperatures within the high temperature range to be measured. Such deformation can be correlated to temperature by calibrating similarly constructed devices under known time and temperature conditions.

  4. High temperature measuring device

    DOEpatents

    Tokarz, Richard D.

    1983-01-01

    A temperature measuring device for very high design temperatures (to 2,000.degree. C.). The device comprises a homogenous base structure preferably in the form of a sphere or cylinder. The base structure contains a large number of individual walled cells. The base structure has a decreasing coefficient of elasticity within the temperature range being monitored. A predetermined quantity of inert gas is confined within each cell. The cells are dimensionally stable at the normal working temperature of the device. Increases in gaseous pressure within the cells will permanently deform the cell walls at temperatures within the high temperature range to be measured. Such deformation can be correlated to temperature by calibrating similarly constructed devices under known time and temperature conditions.

  5. MRI in local staging of rectal cancer: an update

    PubMed Central

    Tapan, Ümit; Özbayrak, Mustafa; Tatlı, Servet

    2014-01-01

    Preoperative imaging for staging of rectal cancer has become an important aspect of current approach to rectal cancer management, because it helps to select suitable patients for neoadjuvant chemoradiotherapy and determine the appropriate surgical technique. Imaging modalities such as endoscopic ultrasonography, computed tomography, and magnetic resonance imaging (MRI) play an important role in assessing the depth of tumor penetration, lymph node involvement, mesorectal fascia and anal sphincter invasion, and presence of distant metastatic diseases. Currently, there is no consensus on a preferred imaging technique for preoperative staging of rectal cancer. However, high-resolution phased-array MRI is recommended as a standard imaging modality for preoperative local staging of rectal cancer, with excellent soft tissue contrast, multiplanar capability, and absence of ionizing radiation. This review will mainly focus on the role of MRI in preoperative local staging of rectal cancer and discuss recent advancements in MRI technique such as diffusion-weighted imaging and dynamic contrast-enhanced MRI. PMID:25010367

  6. Rectal GIST presenting as a submucosal calculus.

    PubMed

    Testroote, Mark; Hoornweg, Marije; Rhemrev, Steven

    2007-04-01

    This case report presents an incidental finding of a rectal GIST (gastrointestinal stromal tumor) presenting as a submucosal calculus, not previously reported. A 53-year-old man without a significant medical history presented with abdominal pain in the left lower quadrant, and with constipation. Upon rectal examination, a hard submucosal swelling was palpated 4 cm from the anus, at 3 o'clock, in the left rectum wall. X-ray photos, computerized tomography (CT)-scan and a magnetic resonance imaging (MRI) scan clearly showed a calculus. Excision revealed a turnip-like lesion, 3.1 x 2.3 x 1.8 cm. Analysis showed it was a rectal GIST, a rare mesenchymal tumor of the gastrointestinal tract, which expressed CD117 (or c-kit, a marker of kit-receptor tyrosine kinase) and CD34. Calcification is not a usual clinicopathological feature of GISTs [1-3], and although a number of rectal GISTs have been reported [4-9], we have found no cases so far of rectal GIST presenting as a submucosal calculus. In general, GISTs are rare mesenchymal tumors of the gastrointestinal tract (nerve tissue, smooth muscle). Histology and immunohistochemistry discriminate gastrointestinal stromal tumors from leiomyomas and neurinomas. The most important location is the stomach; the rectal location is rare. Usually, the classic signs of malignancy such as cellular invasion and metastasis are missing. A set of histologic criteria stratifies GIST for risk of malignant behavior such as mitotic activity and tumor size, cellular pleomorphism, developmental stage of the cell and quantity of cytoplasma [7,13]. Tumors with a high mitotic activity and size above 5 cm are considered malignant. Recent pharmacological advances such as tyrosine kinase inhibitors have determined c-kit (i.e., CD117) as the most important marker, amongst others. C-kit positive tumors respond extremely well to chemotherapy with Imatinib (Glivec, Gleevec) [10-12].

  7. Rectal cancer surgery: a brief history.

    PubMed

    Galler, Avi S; Petrelli, Nicholas J; Shakamuri, Shanthi P

    2011-12-01

    In the last 250 years, the treatment of rectal cancer has changed dramatically. Once considered an incurable disease, combined modality therapy has improved mortality from 100% to less than 4% for locally advanced rectal cancer. This dramatic reduction paralleled surgical techniques based on a growing understanding of anatomy and disease pathology. In order to understand modern treatment, it is necessary to recognize the achievements of preceding surgeons. Copyright © 2010 Elsevier Ltd. All rights reserved.

  8. Mercury toxicity in the shark (Squalus acanthias) rectal gland: apical CFTR chloride channels are inhibited by mercuric chloride.

    PubMed

    Ratner, Martha A; Decker, Sarah E; Aller, Stephen G; Weber, Gerhard; Forrest, John N

    2006-03-01

    In the shark rectal gland, basolateral membrane proteins have been suggested as targets for mercury. To examine the membrane polarity of mercury toxicity, we performed experiments in three preparations: isolated perfused rectal glands, primary monolayer cultures of rectal gland epithelial cells, and Xenopus oocytes expressing the shark cystic fibrosis transmembrane conductance regulator (CFTR) chloride channel. In perfused rectal glands we observed: (1) a dose-dependent inhibition by mercury of forskolin/3-isobutyl-1-methylxanthine (IBMX)-stimulated chloride secretion; (2) inhibition was maximal when mercury was added before stimulation with forskolin/IBMX; (3) dithiothrietol (DTT) and glutathione (GSH) completely prevented inhibition of chloride secretion. Short-circuit current (Isc) measurements in monolayers of rectal gland epithelial cells were performed to examine the membrane polarity of this effect. Mercuric chloride inhibited Isc more potently when applied to the solution bathing the apical vs. the basolateral membrane (23 +/- 5% and 68 +/- 5% inhibition at 1 and 10 microM HgCl2 in the apical solution vs. 2 +/- 0.9% and 14 +/- 5% in the basolateral solution). This inhibition was prevented by pre-treatment with apical DTT or GSH; however, only the permeant reducing agent DTT reversed mercury inhibition when added after exposure. When the shark rectal gland CFTR channel was expressed in Xenopus oocytes and chloride conductance was measured by two-electrode voltage clamping, we found that 1 microM HgCl2 inhibited forskolin/IBMX conductance by 69.2 +/- 2.0%. We conclude that in the shark rectal gland, mercury inhibits chloride secretion by interacting with the apical membrane and that CFTR is the likely site of this action. Copyright 2006 Wiley-Liss, Inc.

  9. Temperature correction in conductivity measurements

    USGS Publications Warehouse

    Smith, Stanford H.

    1962-01-01

    Electrical conductivity has been widely used in freshwater research but usual methods employed by limnologists for converting measurements to conductance at a given temperature have not given uniformly accurate results. The temperature coefficient used to adjust conductivity of natural waters to a given temperature varies depending on the kinds and concentrations of electrolytes, the temperature at the time of measurement, and the temperature to which measurements are being adjusted. The temperature coefficient was found to differ for various lake and stream waters, and showed seasonal changes. High precision can be obtained only by determining temperature coefficients for each water studied. Mean temperature coefficients are given for various temperature ranges that may be used where less precision is required.

  10. Dose Constraint for Minimizing Grade 2 Rectal Bleeding Following Brachytherapy Combined With External Beam Radiotherapy for Localized Prostate Cancer: Rectal Dose-Volume Histogram Analysis of 457 Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shiraishi, Yutaka; Yorozu, Atsunori; Ohashi, Toshio, E-mail: ohashi@rad.med.keio.ac.jp

    2011-11-01

    Purpose: To determine the rectal tolerance to Grade 2 rectal bleeding after I-125 seed brachytherapy combined with external beam radiotherapy (EBRT), based on the rectal dose-volume histogram. Methods and Materials: A total of 458 consecutive patients with stages T1 to T3 prostate cancer received combined modality treatment consisting of I-125 seed implantation followed by EBRT to the prostate and seminal vesicles. The prescribed doses of brachytherapy and EBRT were 100 Gy and 45 Gy in 25 fractions, respectively. The rectal dosimetric factors were analyzed for rectal volumes receiving >100 Gy and >150 Gy (R100 and R150) during brachytherapy and formore » rectal volumes receiving >30 Gy to 40 Gy (V30-V40) during EBRT therapy in 373 patients for whom datasets were available. The patients were followed from 21 to 72 months (median, 45 months) after the I-125 seed implantation. Results: Forty-four patients (9.7%) developed Grade 2 rectal bleeding. On multivariate analysis, age (p = 0.014), R100 (p = 0.002), and V30 (p = 0.001) were identified as risk factors for Grade 2 rectal bleeding. The rectal bleeding rate increased as the R100 increased: 5.0% (2/40 patients) for 0 ml; 7.5% (20/267 patients) for >0 to 0.5 ml; 11.0% (11/100 patients) for >0.5 to 1 ml; 17.9% (5/28 patients) for >1 to 1.5 ml; and 27.3% (6/22 patients) for >1.5 ml (p = 0.014). Grade 2 rectal bleeding developed in 6.4% (12/188) of patients with a V30 {<=}35% and in 14.1% (26/185) of patients with a V30 >35% (p = 0.02). When these dose-volume parameters were considered in combination, the Grade 2 rectal bleeding rate was 4.2% (5/120 patients) for a R100 {<=}0.5 ml and a V30 {<=}35%, whereas it was 22.4% (13/58 patients) for R100 of >0.5 ml and V30 of >35%. Conclusion: The risk of rectal bleeding was found to be significantly volume-dependent in patients with prostate cancer who received combined modality treatment. Rectal dose-volume analysis is a practical method for predicting the risk of

  11. SU-E-T-571: Prostate IMRT QA: Prediction of the Range of Rectal NTCP Using a 2D Field Approach Based on Variations of the Rectal Wall Motion and Thickness.

    PubMed

    Grigorov, G; Chow, J; Foster, K

    2012-06-01

    The aims of this study is to (1) introduce a 2D field of possible rectal normal tissue complication probability (NTCP) in prostate intensity modulated radiotherapy (IMRT) plan, so that based on a given prescribed dose the rectal NTCP is merely a function of the rectal wall thickness and rectal motion; and (2) separate the 2D field of rectal NTCP into area of low risk and area of high risk for rectal toxicity < Grade II, based on the threshold rectal NTCP. The 2D field of NTCP model was developed using ten randomly selected prostate IMRT plans. The clinical rectal geometry was initially represented by the cylindrical contour in the treatment planning system. Different combinations of rectal motions, rectal wall thicknesses, planning target volume margins and prescribed doses were used to determine the NTCP in prostate IMRT plans. It was found that the functions bordering the 2D field for the given AP, LR and SI direction can be described as exponential, quadratic and linear equations, respectively. A ratio of the area of 2D field containing data of the low risk NTCP to the entire area of the field was introduced and calculated. Although our method is based on the Kutcher's dose response model and published tissue parameters, other mathematical models can be used in our approach. The 2D field of rectal NTCP is useful to estimate the rectal NTCP range in the prostate pre-treatment and treatment QA. Our method can determine the patient's threshold immobilization for a given rectal wall thickness so that prescribed dose can be delivered to the prostate to avoid rectal complication. Our method is also applicable to multi-phase prostate IMRT, and can be adapted to any treatment planning systems. © 2012 American Association of Physicists in Medicine.

  12. Life-saving rectal artesunate for complicated malaria in children.

    PubMed

    Pengsaa, Krisana; Sirivichayakul, Chukiat; Na-Bangchang, Kesara; Thaiarporn, Itthipon; Chaivisuth, Anong; Wongsuwan, Amnaj; Attanath, Phanorsri; Pojjaroen-Anant, Chanathep; Wisetsing, Pataraporn; Chanthavanich, Pornthep; Sabchareon, Arunee

    2005-05-01

    We report the effectiveness of two regimens of rectal artesunate formulation in treating 13 Thai children with cerebral/complicated falciparum malaria. The drug was given at an initial dose of 40 mg/kg bodyweight, in 3 or 4 divided doses in the first 24 hours, followed by 10 mg/kg bodyweight once daily for three consecutive days. Mefloquine, at a dose of 15 mg/kg bodyweight was given orally at 72 hours after the initial dose of artesunate, followed by 10 mg/kg bodyweight 6 hours later. Three cases with cerebral malaria gained consciousness within 20 hours of artesunate administration. The median time required for reduction of parasitemia by 90% of the initial value (P90) in 13 children was 11.2 hours. No recrudescence was observed in any of the patients during the 28-day follow-up period. Plasma concentrations of artesunate and dihydroartemisinin (active plasma metabolite of artesunate) measured in two patients who received the high initial dose regimen (20 mg/ kg bodyweight) suggested rapid absorption and adequate plasma concentrations of both compounds following the administration of artesunate via the rectal route. Further studies for the optimized regimen of rectal artesunate in the treatment of cerebral/complicated childhood falciparum malaria in areas of multidrug resistance are warranted.

  13. Intramuscular and rectal therapies of acute seizures.

    PubMed

    Leppik, Ilo E; Patel, Sima I

    2015-08-01

    The intramuscular (IM) and rectal routes are alternative routes of delivery for antiepileptic drugs (AEDs) when the intravenous route is not practical or possible. For treatment of acute seizures, the AED used should have a short time to maximum concentration (Tmax). Some AEDs have preparations that may be given intramuscularly. These include the benzodiazepines (diazepam, lorazepam, and midazolam) and others (fosphenytoin, levetiracetam). Although phenytoin and valproate have parenteral preparations, these should not be given intramuscularly. A recent study of prehospital treatment of status epilepticus evaluated a midazolam (MDZ) autoinjector delivering IM drug compared to IV lorazepam (LZP). Seizures were absent on arrival to the emergency department in 73.4% of the IM MDZ compared to a 63.4% response in LZP-treated subjects (p < 0.001 for superiority). Almost all AEDs have been evaluated for rectal administration as solutions, gels, and suppositories. In a placebo-controlled study, diazepam (DZP) was administered at home by caregivers in doses that ranged from 0.2 to 0.5 mg/kg. Diazepam was superior to placebo in reduced seizure frequency in children (p < 0.001) and in adults (p = 0.02) and time to recurrent seizures after an initial treatment (p < 0.001). Thus, at this time, only MZD given intramuscularly and DZP given rectally appear to have the properties required for rapid enough absorption to be useful when intravenous routes are not possible. Some drugs cannot be administered rectally owing to factors such as poor absorption or poor solubility in aqueous solutions. The relative rectal bioavailability of gabapentin, oxcarbazepine, and phenytoin is so low that the current formulations are not considered to be suitable for administration by this route. When administered as a solution, diazepam is rapidly absorbed rectally, reaching the Tmax within 5-20 min in children. By contrast, rectal administration of lorazepam is relatively slow, with a Tmax of 1-2h

  14. Anaphylaxis to gelatin-containing rectal suppositories.

    PubMed

    Sakaguchi, M; Inouye, S

    2001-12-01

    Some children--though the number is few-have been sensitized with gelatin. To investigate the relationship between the presence of antigelatin IgE and anaphylaxis to gelatin-containing rectal suppository, we measured antigelatin IgE in the sera of the children with anaphylaxis. Ten children showed systemic allergic reactions, including anaphylaxis, to a chloral hydrate rectal suppository containing gelatin (231 mg/dose) that had been used as a sedative. These children's clinical histories and serum samples were submitted from physicians to the National Institute of Infectious Diseases during a 2-year period from 1996 to 1997. Of the 10 children, 5 showed apparent anaphylaxis, including hypotension and/or cyanosis, along with urticaria or wheezing; 2 showed both urticaria and wheezing without hypotension or cyanosis; the other 3 showed only urticaria. All of the children had antigelatin IgE (mean value +/- SD, 7.9 +/- 8.4 Ua/mL). As a control, samples from 250 randomly selected children had no antigelatin IgE. These findings suggest that the 10 children's systemic allergic reactions to this suppository were caused by the gelatin component. Gelatin-containing suppositories must be used with the same caution as gelatin-containing vaccines and other medications.

  15. First investigations to refine video-based IR thermography as a non-invasive tool to monitor the body temperature of calves.

    PubMed

    Hoffmann, G; Schmidt, M; Ammon, C

    2016-09-01

    In this study, a video-based infrared camera (IRC) was investigated as a tool to monitor the body temperature of calves. Body surface temperatures were measured contactless using videos from an IRC fixed at a certain location in the calf feeder. The body surface temperatures were analysed retrospectively at three larger areas: the head area (in front of the forehead), the body area (behind forehead) and the area of the entire animal. The rectal temperature served as a reference temperature and was measured with a digital thermometer at the corresponding time point. A total of nine calves (Holstein-Friesians, 8 to 35 weeks old) were examined. The average maximum temperatures of the area of the entire animal (mean±SD: 37.66±0.90°C) and the head area (37.64±0.86°C) were always higher than that of the body area (36.75±1.06°C). The temperatures of the head area and of the entire animal were very similar. However, the maximum temperatures as measured using IRC increased with an increase in calf rectal temperature. The maximum temperatures of each video picture for the entire visible body area of the calves appeared to be sufficient to measure the superficial body temperature. The advantage of the video-based IRC over conventional IR single-picture cameras is that more than one picture per animal can be analysed in a short period of time. This technique provides more data for analysis. Thus, this system shows potential as an indicator for continuous temperature measurements in calves.

  16. Rectal cancer and Fournier’s gangrene - current knowledge and therapeutic options

    PubMed Central

    Bruketa, Tomislav; Majerovic, Matea; Augustin, Goran

    2015-01-01

    Fournier’s gangrene (FG) is a rapid progressive bacterial infection that involves the subcutaneous fascia and part of the deep fascia but spares the muscle in the scrotal, perianal and perineal region. The incidence has increased dramatically, while the reported incidence of rectal cancer-induced FG is unknown but is extremely low. Pathophysiology and clinical presentation of rectal cancer-induced FG per se does not differ from the other causes. Only rectal cancer-specific symptoms before presentation can lead to the diagnosis. The diagnosis of rectal cancer-induced FG should be excluded in every patient with blood on digital rectal examination, when urogenital and dermatological causes are excluded and when fever or sepsis of unknown origin is present with perianal symptomatology. Therapeutic options are more complex than for other forms of FG. First, the causative rectal tumor should be removed. The survival of patients with rectal cancer resection is reported as 100%, while with colostomy it is 80%. The preferred method of rectal resection has not been defined. Second, oncological treatment should be administered but the timing should be adjusted to the resolution of the FG and sometimes for the healing of plastic reconstructive procedures that are commonly needed for the reconstruction of large perineal, scrotal and lower abdominal wall defects. PMID:26290629

  17. Comparison of complication and conversion rates between robotic-assisted and laparoscopic rectal resection for rectal cancer: which patients and providers could benefit most from robotic-assisted surgery?

    PubMed

    Ackerman, Stacey J; Daniel, Shoshana; Baik, Rebecca; Liu, Emelline; Mehendale, Shilpa; Tackett, Scott; Hellan, Minia

    2018-03-01

    To compare (1) complication and (2) conversion rates to open surgery (OS) from laparoscopic surgery (LS) and robotic-assisted surgery (RA) for rectal cancer patients who underwent rectal resection. (3) To identify patient, physician, and hospital predictors of conversion. A US-based database study was conducted utilizing the 2012-2014 Premier Healthcare Data, including rectal cancer patients ≥18 with rectal resection. ICD-9-CM diagnosis and procedural codes were utilized to identify surgical approaches, conversions to OS, and surgical complications. Propensity score matching on patient, surgeon, and hospital level characteristics was used to create comparable groups of RA\\LS patients (n = 533 per group). Predictors of conversion from LS and RA to OS were identified with stepwise logistic regression in the unmatched sample. Post-match results suggested comparable perioperative complication rates (RA 29% vs LS 29%; p = .7784); whereas conversion rates to OS were 12% for RA vs 29% for LS (p < .0001). Colorectal surgeons (RA 9% vs LS 23%), general surgeons (RA 13% vs LS 35%), and smaller bed-size hospitals (RA 14% vs LS 33%) have reduced conversion rates for RA vs LS (p < .0001). Statistically significant predictors of conversion included LS, non-colorectal surgeon, and smaller bed-size hospitals. Retrospective observational study limitations apply. Analysis of the hospital administrative database was subject to the data captured in the database and the accuracy of coding. Propensity score matching limitations apply. RA and LS groups were balanced with respect to measured patient, surgeon, and hospital characteristics. Compared to LS, RA offers a higher probability of completing a successful minimally invasive surgery for rectal cancer patients undergoing rectal resection without exacerbating complications. Male, obese, or moderately-to-severely ill patients had higher conversion rates. While colorectal surgeons had lower conversion rates from RA

  18. Accuracy of tympanic and infrared skin thermometers in children.

    PubMed

    Paes, B F; Vermeulen, K; Brohet, R M; van der Ploeg, T; de Winter, J P

    2010-12-01

    Rectal measurement is considered a gold standard in many healthcare systems for body temperature measurement in children. Although this method has several disadvantages, an ideal alternative thermometer has not yet been introduced. However tympanic and infrared skin thermometers are potential alternatives. A prospective cohort study was performed including 100 children between 0 and 18 years of age admitted to the general paediatric ward of Spaarne Hospital in The Netherlands between January and March 2009. The objectives of this study are to evaluate the accuracy of tympanic and two types of infrared skin thermometers (Beurer and Thermofocus) compared to rectal measurement and furthermore to evaluate the influence of different variables on temperature measurements. Compared to rectal measurement (37.56°C), the mean temperatures of the tympanic (37.29°C), Beurer (36.79°C) and Thermofocus (37.30°C) thermometers differed significantly (p<0.001). Mean and SD of differences between rectal temperature and temperature measured with these alternative devices varied significantly (p<0.001). Sensitivity, specificity, positive and negative predictive values for detecting rectal fever measured with the tympanic, Beurer and Thermofocus thermometers are unacceptable, especially for the Beurer thermometer. This difference in temperature between rectal and the alternative thermometers remained after stratification on gender, age, skin colour and otoscopic abnormalities. In this study the authors demonstrated that the tympanic, Beurer and Thermofocus thermometers cannot reliably predict rectal temperature. Therefore the authors do not advise replacement of rectal measurement as the gold standard for detecting fever in children by one of these devices. When rectal measurement is not used, the infrared skin thermometers appear to perform less well than tympanic measurements.

  19. The effects of gender on circadian rhythm of human physiological indexes in high temperature environment

    NASA Astrophysics Data System (ADS)

    Zheng, G. Z.; Li, K.; Bu, W. T.; Lu, Y. Z.; Wang, Y. J.

    2018-03-01

    In the context of frequent high temperature weather in recent years, peoples’ physical health is seriously threatened by the indoor high temperature. The physiological activities of human body show a certain changes of circadian rhythm. In this paper, the circadian rhythms of the physiological indexes in indoor high temperature environment were quantified and compared between the male subjects and female subjects. Ten subjects (five males and five females) were selected. The temperature conditions were set at 28°C, 32°C, 36°C and 38°C, respectively. The blood pressure, heart rate, rectal temperature, eardrum temperature, forehead temperature and mean skin temperature were measured for 24 hours continuously. The medians, amplitudes and acrophases of the circadian rhythms were obtained by the cosinor analysis method. Then the effects of gender on the circadian rhythm of the human body in high temperature environment were analyzed. The results indicate that, compared with the female subjects, the male medians of the systolic pressure and diastolic pressure were higher, and the male medians of heart rate and rectal temperature were lower, however, no significant differences were found between eardrum temperature, forehead temperature and mean skin temperature. This study can provide scientific basis for the health protection of the indoor relevant personnel.

  20. Noncontact Temperature Measurement

    NASA Technical Reports Server (NTRS)

    Lee, Mark C. (Editor)

    1988-01-01

    Noncontact temperature measurement has been identified as one of the eight advanced technology development (ATD) areas to support the effort of the Microgravity Science and Applications Division in developing six Space Station flight experiment facilities. This two-day workshop was an opportunity for all six disciplines to present their requirements on noncontact temperature measurement and to discuss state-of-the-art developments. Multi-color pyrometry, laser pyrometry and radiometric imaging techniques are addressed.

  1. Rectal distensibility and symptoms after stapled and Milligan-Morgan operation for hemorrhoids.

    PubMed

    Corsetti, Maura; De Nardi, Paola; Di Pietro, Salvatore; Passaretti, Sandro; Testoni, Pier Alberto; Staudacher, Carlo

    2009-12-01

    In a previous uncontrolled study, a reduction of rectal distensibility and volume thresholds for sensations have been related to the occurrence of fecal urgency and/or increased stool frequency after stapled hemorrhoidopexy. The aim of this study was to compare rectal symptoms and sensory-motor function after stapled hemorrhoidopexy and Milligan-Morgan hemorrhoidectomy. The clinical records of 12 (four women) and ten patients (four women) with third- and fourth-degree hemorrhoids, respectively, who underwent stapled hemorrhoidopexy or Milligan-Morgan's hemorrhoidectomy, were evaluated. One week before and 6 months after surgery, rectal motor and sensory response to distension was assessed by an electronic barostat, and bowel and rectal symptoms were recorded by means of a 7-day diary and Bristol Index scale and psychological symptoms with SCL-90 questionnaire. Rectal distensibility and volume thresholds for sensations were significantly lower after surgery (P < 0.02) in the stapled group. Increased stool frequency and/or fecal urgency arose in 41% of patients in the stapled group and associated with altered rectal distensibility. No difference within and between groups could be demonstrated in SCL-90 score. Rectal distensibility and volume thresholds for sensations decrease after stapled hemorrhoidopexy. Altered rectal distensibility was associated with rectal urgency and/or increased stool frequency.

  2. Technical note: Assessment of an alternative technique for measuring body temperature in pigs.

    PubMed

    Petry, A; McGilvray, W; Rakhshandeh, A R; Rakhshandeh, A

    2017-07-01

    Core body temperature (CBT) is one of the main vital signs that is used to evaluate the health status of pigs. The most common and feasible method for assessing CBT in pigs is rectal temperature (RT). Obtaining RT is stressful for animals, may generate inaccurate results, and has the risk of spreading disease. Infrared imaging (IR) thermography of the body of pigs may be a safer and less stressful alternative to RT. The objective of the current study was to evaluate the efficacy of using IR as an alternative for monitoring CBT in pigs. Twenty-three gilts (30.5 ± 5.62 kg BW) were housed in metabolism crates in an environmentally controlled facility and fed an 860 g/d grower diet. After 4 d of adaptation, the febrile response was induced by intramuscular injection of lipopolysaccharide (LPS; 25 µg/kg BW). Each pig's body temperature was recorded at 0, 2, 4, 6, 8, 10, and 24 h after LPS challenge using the following 3 methods: 1) RT, 2) IR of the eye and ear, and 3) CBT using an orally administered digital temperature sensor. Statistical analysis was performed in a completely randomized design in SAS using Mixed, Correlation, and Regression procedures. Relative to time 0 h, LPS increased the eye temperature, CBT, and RT by 0.92, 1.32, and 1.48°C, respectively ( < 0.01), but had no significant effect on ear temperature. Eye temperature, RT, and CBT, but not ear temperature, were highly correlated ( ≥ 0.96) during the course of the study ( < 0.01). Estimated regression parameters (α and β) for predicting CBT using eye temperature were -28.2 ± 8.70 and 1.76 ± 0.221, respectively, and for RT were -24.5 ± 7.69 and 1.65 ± 0.196, respectively ( ≥ 0.96; 95% confidence interval). Collectively, these results indicated a strong relationship between eye temperature, RT, and CBT in pigs. Therefore, IR of the eye can be used as a precise, noncontact alternative to RT measurements for monitoring CBT in swine.

  3. Respiratory alkalosis and primary hypocapnia in Labrador Retrievers participating in field trials in high-ambient-temperature conditions.

    PubMed

    Steiss, Janet E; Wright, James C

    2008-10-01

    To determine whether Labrador Retrievers participating in field trials develop respiratory alkalosis and hypocapnia primarily in conditions of high ambient temperatures. 16 Labrador Retrievers. At each of 5 field trials, 5 to 10 dogs were monitored during a test (retrieval of birds over a variable distance on land [1,076 to 2,200 m]; 36 assessments); ambient temperatures ranged from 2.2 degrees to 29.4 degrees C. For each dog, rectal temperature was measured and a venous blood sample was collected in a heparinized syringe within 5 minutes of test completion. Blood samples were analyzed on site for Hct; pH; sodium, potassium, ionized calcium, glucose, lactate, bicarbonate, and total CO2 concentrations; and values of PvO2 and PvCO2. Scatterplots of each variable versus ambient temperature were reviewed. Regression analysis was used to evaluate the effect of ambient temperature (< or = 21 degrees C and > 21 degrees C) on each variable. Compared with findings at ambient temperatures < or = 21 degrees C, venous blood pH was increased (mean, 7.521 vs 7.349) and PvCO2 was decreased (mean, 17.8 vs 29.3 mm Hg) at temperatures > 21 degrees C; rectal temperature did not differ. Two dogs developed signs of heat stress in 1 test at an ambient temperature of 29 degrees C; their rectal temperatures were higher and PvCO2 values were lower than findings in other dogs. When running distances frequently encountered at field trials, healthy Labrador Retrievers developed hyperthermia regardless of ambient temperature. Dogs developed respiratory alkalosis and hypocapnia at ambient temperatures > 21 degrees C.

  4. ¹H NMR-based metabolic profiling of human rectal cancer tissue

    PubMed Central

    2013-01-01

    Background Rectal cancer is one of the most prevalent tumor types. Understanding the metabolic profile of rectal cancer is important for developing therapeutic approaches and molecular diagnosis. Methods Here, we report a metabonomics profiling of tissue samples on a large cohort of human rectal cancer subjects (n = 127) and normal controls (n = 43) using 1H nuclear magnetic resonance (1H NMR) based metabonomics assay, which is a highly sensitive and non-destructive method for the biomarker identification in biological systems. Principal component analysis (PCA), partial least squares discriminant analysis (PLS-DA) and orthogonal projection to latent structure with discriminant analysis (OPLS-DA) were applied to analyze the 1H-NMR profiling data to identify the distinguishing metabolites of rectal cancer. Results Excellent separation was obtained and distinguishing metabolites were observed among the different stages of rectal cancer tissues (stage I = 35; stage II = 37; stage III = 37 and stage IV = 18) and normal controls. A total of 38 differential metabolites were identified, 16 of which were closely correlated with the stage of rectal cancer. The up-regulation of 10 metabolites, including lactate, threonine, acetate, glutathione, uracil, succinate, serine, formate, lysine and tyrosine, were detected in the cancer tissues. On the other hand, 6 metabolites, including myo-inositol, taurine, phosphocreatine, creatine, betaine and dimethylglycine were decreased in cancer tissues. These modified metabolites revealed disturbance of energy, amino acids, ketone body and choline metabolism, which may be correlated with the progression of human rectal cancer. Conclusion Our findings firstly identify the distinguishing metabolites in different stages of rectal cancer tissues, indicating possibility of the attribution of metabolites disturbance to the progression of rectal cancer. The altered metabolites may be as potential biomarkers, which would

  5. Rectal bleeding and implications for surgical care in Nepal.

    PubMed

    Tessler, Robert; Gupta, Shailvi; Pathak, John; Ghimire, Pranita; Kingham, Thomas P; Kushner, Adam L; Amatya, Kapendra Shekhar; Nwomeh, Benedict C

    2015-07-01

    Because rectal bleeding is a cardinal symptom of many colorectal diseases including colorectal cancers, its presence alone could give insight into the prevalence of these conditions where direct population screening is lacking. In South Asia, which is home to over one fifth of the world's population, there is paucity of epidemiologic data on colorectal diseases, particularly in the lower-income countries such as Nepal. The aim of this study was to enumerate the prevalence of rectal bleeding in Nepal and increase understanding of colorectal diseases as a health problem in the South Asian region. A countrywide survey using the Surgeons OverSeas Assessment of Surgical Need tool was administered from May 25-June 12, 2014 in 15 of the 75 districts of Nepal, randomly selected proportional to population. In each district, three Village Development Committees were selected randomly, two rural and one urban based on the Demographic Health Survey methodology. Individuals were interviewed to determine the period and point prevalence of rectal bleeding and patterns of health-seeking behavior related to surgical care for this problem. Individuals aged >18 y were included in this analysis. A total of 1350 households and 2695 individuals were surveyed with a 97% response rate. Thirty-eight individuals (55% male) of the 1941 individuals ≥ 18 y stated they had experienced rectal bleeding (2.0%, 95% confidence interval 1.4%-2.7%), with a mean age of 45.5 (standard deviation 2.2). Of these 38 individuals, 30 stated they currently experience rectal bleeding. Health Care was sought in 18 participants with current rectal bleeding, with two major procedures performed, one an operation for an anal fistula. For those who sought health care but did not receive surgical care, reasons included no need (4), not available (6), fear and/or no trust (5), and no money for health care (1). For those with current rectal bleeding who did not seek health care, reasons included no need (1), not

  6. Rectal cancer: An evidence-based update for primary care providers

    PubMed Central

    Gaertner, Wolfgang B; Kwaan, Mary R; Madoff, Robert D; Melton, Genevieve B

    2015-01-01

    Rectal adenocarcinoma is an important cause of cancer-related deaths worldwide, and key anatomic differences between the rectum and the colon have significant implications for management of rectal cancer. Many advances have been made in the diagnosis and management of rectal cancer. These include clinical staging with imaging studies such as endorectal ultrasound and pelvic magnetic resonance imaging, operative approaches such as transanal endoscopic microsurgery and laparoscopic and robotic assisted proctectomy, as well as refined neoadjuvant and adjuvant therapies. For stage II and III rectal cancers, combined chemoradiotherapy offers the lowest rates of local and distant relapse, and is delivered neoadjuvantly to improve tolerability and optimize surgical outcomes, particularly when sphincter-sparing surgery is an endpoint. The goal in rectal cancer treatment is to optimize disease-free and overall survival while minimizing the risk of local recurrence and toxicity from both radiation and systemic therapy. Optimal patient outcomes depend on multidisciplinary involvement for tailored therapy. The successful management of rectal cancer requires a multidisciplinary approach, with the involvement of enterostomal nurses, gastroenterologists, medical and radiation oncologists, radiologists, pathologists and surgeons. The identification of patients who are candidates for combined modality treatment is particularly useful to optimize outcomes. This article provides an overview of the diagnosis, staging and multimodal therapy of patients with rectal cancer for primary care providers. PMID:26167068

  7. [Ergotamine-induced rectal stenosis in a patient with long-term migraine].

    PubMed

    Machnig, T; May, A; Steininger, H; von Streitberg, U; Hahn, E G; Ell, C

    1993-07-01

    A 36 year old woman was admitted to our hospital for treatment of a high-grade rectal stenosis of unknown origin. She had a history of migraine going back 10 years. On intensive questioning she admitted using up to 5 ergotamine-containing suppositories a day. On the basis of history and clinical investigations the rectal stenosis must be connected with the abuse of ergotamine-containing suppositories. This case demonstrates that patients with an unexplained rectal syndrome should be asked for analgetics-containing suppositories specifically. Only discontinuation of treatment in time can preserve the patient from development of a rectal stenosis. In case of a rectal stenosis surgical treatment can be avoided by means of endoscopic controlled dilatation.

  8. Effect of transportation during periods of high ambient temperature on physiologic and behavioral indices of beef heifers.

    PubMed

    Theurer, Miles E; White, Brad J; Anderson, David E; Miesner, Matt D; Mosier, Derek A; Coetzee, Johann F; Amrine, David E

    2013-03-01

    To determine the effect of transportation during periods of high ambient temperature on physiologic and behavioral indices of beef heifers. 20 heifers (mean body weight, 217.8 kg). Ten heifers were transported 518 km when the maximum ambient temperature was ≥ 32.2°C while the other 10 heifers served as untransported controls. Blood samples were collected from transported heifers at predetermined intervals during the transportation period. For all heifers, body weights, nasal and rectal temperatures, and behavioral indices were measured at predetermined intervals for 3 days after transportation. A week later, the entire process was repeated such that each group was transported twice and served as the control twice. Transported heifers spent more time near the hay feeder on the day of transportation, had lower nasal and rectal temperatures for 24 hours after transportation, and spent more time lying down for 2 days after transportation, compared with those indices for control heifers. Eight hours after transportation, the weight of transported heifers decreased 6%, whereas that of control heifers increased 0.6%. At 48 hours after initiation of transportation, weight, rectal temperature, and time spent at various pen locations did not differ between transported and control heifers. Cortisol concentrations were higher 4 hours after initiation of transportation, compared with those determined just prior to transportation. Results indicated transportation during periods of high ambient temperatures caused transient changes in physiologic and behavioral indices of beef heifers.

  9. A systematic review of body temperature variations in older people.

    PubMed

    Lu, Shu-Hua; Leasure, Angela-Renee; Dai, Yu-Tzu

    2010-01-01

    The purpose of this systematic review was to determine the extent to which the research literature indicates body temperature norms in the geriatric population. The specific questions addressed were to examine normal body temperature values in persons 60 years of age and older; determine differences in temperature values depending on non-invasive measurement site and measurement device used; and, examine the degree and extent of temperature variability according to time of day and time of year. The traditional 'normal' temperature of 98.6 degrees F/37 degrees C may in fact be lower in older people due to the ageing process. Age-associated changes in vasomotor sweating function, skeletal muscle response, temperature perception and physical behaviours may influence the ability to maintain optimum temperature. A systematic literature review. A search of multiple databases yielded 22 papers which met inclusion criteria. Studies were included which focused on temperature measurement, sampled persons 60 years of age and older, collected data from non-invasive temperature measurement sites and which used a prospective study design. Studies were independently appraised using a structured appraisal format. Temperature normal values by site were rectal 98.8 degrees F/37.1 degrees C, ear-based 98.3 degrees F/36.8 degrees C, urine 97.6 degrees F/36.5 degrees C, oral 97.4 degrees F/36.3 degrees C and axillary 97.1 degrees F/36.2 degrees C. Temperature exhibited a 0.7 degrees F/0.4 degrees C diurnal and 0.2 degrees F/0.1 degrees C circannual variation. Synthesis of data indicated that normal body temperature values in older people by sites were rectal 0.7 degrees F/0.4 degrees C, ear-based 0.3 degrees F/0.2 degrees C, oral 1.2 degrees F/0.7 degrees C, axillary 0.6 degrees F/0.3 degrees C lower than adults' acceptable value from those traditionally found in nursing textbooks. Given the fact that normal body temperature values were consistently lower than values reported in the

  10. Containerless high temperature property measurements

    NASA Technical Reports Server (NTRS)

    Nordine, Paul C.; Weber, J. K. Richard; Krishnan, Shankar; Anderson, Collin D.

    1991-01-01

    Containerless processing in the low gravity environment of space provides the opportunity to increase the temperature at which well controlled processing of and property measurements on materials is possible. This project was directed towards advancing containerless processing and property measurement techniques for application to materials research at high temperatures in space. Containerless high temperature material property studies include measurements of the vapor pressure, melting temperature, optical properties, and spectral emissivities of solid boron. The reaction of boron with nitrogen was also studied by laser polarimetric measurement of boron nitride film growth. The optical properties and spectral emissivities were measured for solid and liquid silicon, niobium, and zirconium; liquid aluminum and titanium; and liquid Ti-Al alloys of 5 to 60 atomic pct. titanium. Alternative means for noncontact temperature measurement in the absence of material emissivity data were evaluated. Also, the application of laser induced fluorescence for component activity measurements in electromagnetic levitated liquids was studied, along with the feasibility of a hybrid aerodynamic electromagnetic levitation technique.

  11. Colon and rectal injuries.

    PubMed

    Cleary, Robert K; Pomerantz, Richard A; Lampman, Richard M

    2006-08-01

    This study was designed to develop treatment algorithms for colon, rectal, and anal injuries based on the review of relevant literature. Information was obtained through a MEDLINE ( www.nobi.nih.gov/entrez/query.fcgi ) search, and additional references were obtained through cross-referencing key articles cited in these papers. A total of 203 articles were considered relevant. The management of penetrating and blunt colon, rectal, and anal injuries has evolved during the past 150 years. Since the World War II mandate to divert penetrating colon injuries, primary repair or resection and anastomosis have found an increasing role in patients with nondestructive injuries. A critical review of recent literature better defines the role of primary repair and fecal diversion for these injuries and allows for better algorithms for the management of these injuries.

  12. Body temperature and motion: Evaluation of an online monitoring system in pigs challenged with Porcine Reproductive & Respiratory Syndrome Virus.

    PubMed

    Süli, Tamás; Halas, Máté; Benyeda, Zsófia; Boda, Réka; Belák, Sándor; Martínez-Avilés, Marta; Fernández-Carrión, Eduardo; Sánchez-Vizcaíno, José Manuel

    2017-10-01

    Highly contagious and emerging diseases cause significant losses in the pig producing industry worldwide. Rapid and exact acquisition of real-time data, like body temperature and animal movement from the production facilities would enable early disease detection and facilitate adequate response. In this study, carried out within the European Union research project RAPIDIA FIELD, we tested an online monitoring system on pigs experimentally infected with the East European subtype 3 Porcine Reproductive & Respiratory Syndrome Virus (PRRSV) strain Lena. We linked data from different body temperature measurement methods and the real-time movement of the pigs. The results showed a negative correlation between body temperature and movement of the animals. The correlation was similar with both body temperature obtaining methods, rectal and thermal sensing microchip, suggesting some advantages of body temperature measurement with transponders compared with invasive and laborious rectal measuring. We also found a significant difference between motion values before and after the challenge with a virulent PRRSV strain. The decrease in motion values was noticeable before any clinical sign was recorded. Based on our results the online monitoring system could represent a practical tool in registering early warning signs of health status alterations, both in experimental and commercial production settings. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Dual-wavelengths photoacoustic temperature measurement

    NASA Astrophysics Data System (ADS)

    Liao, Yu; Jian, Xiaohua; Dong, Fenglin; Cui, Yaoyao

    2017-02-01

    Thermal therapy is an approach applied in cancer treatment by heating local tissue to kill the tumor cells, which requires a high sensitivity of temperature monitoring during therapy. Current clinical methods like fMRI near infrared or ultrasound for temperature measurement still have limitations on penetration depth or sensitivity. Photoacoustic temperature sensing is a newly developed temperature sensing method that has a potential to be applied in thermal therapy, which usually employs a single wavelength laser for signal generating and temperature detecting. Because of the system disturbances including laser intensity, ambient temperature and complexity of target, the accidental errors of measurement is unavoidable. For solving these problems, we proposed a new method of photoacoustic temperature sensing by using two wavelengths to reduce random error and increase the measurement accuracy in this paper. Firstly a brief theoretical analysis was deduced. Then in the experiment, a temperature measurement resolution of about 1° in the range of 23-48° in ex vivo pig blood was achieved, and an obvious decrease of absolute error was observed with averagely 1.7° in single wavelength pattern while nearly 1° in dual-wavelengths pattern. The obtained results indicates that dual-wavelengths photoacoustic sensing of temperature is able to reduce random error and improve accuracy of measuring, which could be a more efficient method for photoacoustic temperature sensing in thermal therapy of tumor.

  14. Transanal endoscopic microsurgery versus endoscopic mucosal resection for large rectal adenomas (TREND-study).

    PubMed

    van den Broek, Frank J C; de Graaf, Eelco J R; Dijkgraaf, Marcel G W; Reitsma, Johannes B; Haringsma, Jelle; Timmer, Robin; Weusten, Bas L A M; Gerhards, Michael F; Consten, Esther C J; Schwartz, Matthijs P; Boom, Maarten J; Derksen, Erik J; Bijnen, A Bart; Davids, Paul H P; Hoff, Christiaan; van Dullemen, Hendrik M; Heine, G Dimitri N; van der Linde, Klaas; Jansen, Jeroen M; Mallant-Hent, Rosalie C H; Breumelhof, Ronald; Geldof, Han; Hardwick, James C H; Doornebosch, Pascal G; Depla, Annekatrien C T M; Ernst, Miranda F; van Munster, Ivo P; de Hingh, Ignace H J T; Schoon, Erik J; Bemelman, Willem A; Fockens, Paul; Dekker, Evelien

    2009-03-13

    Recent non-randomized studies suggest that extended endoscopic mucosal resection (EMR) is equally effective in removing large rectal adenomas as transanal endoscopic microsurgery (TEM). If equally effective, EMR might be a more cost-effective approach as this strategy does not require expensive equipment, general anesthesia and hospital admission. Furthermore, EMR appears to be associated with fewer complications.The aim of this study is to compare the cost-effectiveness and cost-utility of TEM and EMR for the resection of large rectal adenomas. Multicenter randomized trial among 15 hospitals in the Netherlands. Patients with a rectal adenoma > or = 3 cm, located between 1-15 cm ab ano, will be randomized to a TEM- or EMR-treatment strategy. For TEM, patients will be treated under general anesthesia, adenomas will be dissected en-bloc by a full-thickness excision, and patients will be admitted to the hospital. For EMR, no or conscious sedation is used, lesions will be resected through the submucosal plane in a piecemeal fashion, and patients will be discharged from the hospital. Residual adenoma that is visible during the first surveillance endoscopy at 3 months will be removed endoscopically in both treatment strategies and is considered as part of the primary treatment. Primary outcome measure is the proportion of patients with recurrence after 3 months. Secondary outcome measures are: 2) number of days not spent in hospital from initial treatment until 2 years afterwards; 3) major and minor morbidity; 4) disease specific and general quality of life; 5) anorectal function; 6) health care utilization and costs. A cost-effectiveness and cost-utility analysis of EMR against TEM for large rectal adenomas will be performed from a societal perspective with respectively the costs per recurrence free patient and the cost per quality adjusted life year as outcome measures. Based on comparable recurrence rates for TEM and EMR of 3.3% and considering an upper-limit of 10

  15. Laser Pyrometer For Spot Temperature Measurements

    NASA Technical Reports Server (NTRS)

    Elleman, D. D.; Allen, J. L.; Lee, M. C.

    1988-01-01

    Laser pyrometer makes temperature map by scanning measuring spot across target. Scanning laser pyrometer passively measures radiation emitted by scanned spot on target and calibrated by similar passive measurement on blackbody of known temperature. Laser beam turned on for active measurements of reflectances of target spot and reflectance standard. From measurements, temperature of target spot inferred. Pyrometer useful for non-contact measurement of temperature distributions in processing of materials.

  16. Temperature Pill

    NASA Technical Reports Server (NTRS)

    1988-01-01

    Ingestible Thermal Monitoring System was developed at Johns Hopkins University as means of getting internal temperature readings for treatments of such emergency conditions as dangerously low (hypothermia) and dangerously high (hyperthermia) body temperatures. ITMS's accuracy is off no more than one hundredth of a degree and provides the only means of obtaining deep body temperature. System has additional applicability in fertility monitoring and some aspects of surgery, critical care obstetrics, metabolic disease treatment, gerontology (aging) and food processing research. Three-quarter inch silicone capsule contains telemetry system, micro battery, and a quartz crystal temperature sensor inserted vaginally, rectally, or swallowed.

  17. Adherence to Rectal Mesalamine in Patients with Ulcerative Colitis.

    PubMed

    Boyle, Marie; Ting, Amanda; Cury, Didia B; Nanda, Kavinderjit; Cheifetz, Adam S; Moss, Alan

    2015-12-01

    Rectal mesalamine is an effective induction and maintenance therapy for ulcerative colitis. Little is known about the adherence rates to rectal mesalamine or barriers to its use. The aim was to quantify the prevalence of nonadherence to rectal mesalamine and to identify patient-reported barriers to adherence. A cohort of patients with ulcerative colitis was prospectively enrolled in this observational study and followed for 12 months. Adherence was assessed by tracking pharmacy refills (medication possession ratio). Individual interviews were undertaken in a subset of subjects. Transcripts from the focus groups and interviews were analyzed to identify themes and links between these themes using qualitative data software (MaxQDA). Seventy patients prescribed rectal mesalamine were prospectively enrolled in the study. At enrollment, 39 of 70 subjects (55%) self-reported "occasional nonadherence" to rectal mesalamine. Over the 12-month follow-up period, only 20 subjects (26%) completed 3 or more refills. Males, or subjects prescribed a once-a-day suppository, were significantly more likely to refill than females (odds ratio = 3.3, 95% confidence interval, 1.1-10.9) or those prescribed suppositories more than once a day (odds ratio = 1.3, 95% confidence interval, 1.1-1.7). By medication possession ratio criteria, 71% of all subjects were nonadherent with their prescribed regimen (medication possession ratio <0.6). Nonadherers were significantly older than adherent subjects: mean age 48 years in nonadherers, versus 37 in adherers, P = 0.04. Patients who were nonadherent to rectal mesalamine frequently cited the mode of administration (65%) and busy lifestyle (40%) as reasons for nonadherence. Intentional nonadherence is common in patients who have been prescribed rectal mesalamine. Gender, age, frequency of dosing, and lifestyle factors may impact adherence.

  18. Advances in organ preserving strategies in rectal cancer patients.

    PubMed

    Stijns, Rutger C H; Tromp, Mike-Stephen R; Hugen, Niek; de Wilt, Johannes H W

    2018-02-01

    Treatment of rectal cancer patients has been subjected to change over the past thirty years. Total mesorectal excision is considered the cornerstone of rectal cancer treatment, but is also associated with significant morbidity resulting in an impaired quality of life. The addition of neoadjuvant chemoradiotherapy to surgery has shown to improve survival and local control and may lead to a partial or even complete response (CR). This raises questions regarding the necessity for subsequent radical surgery. After careful patient selection local excision and wait-and-see approaches are explored, aiming to improve quality of life without compromising oncological outcome. A multimodality diagnostic approach for optimal staging is crucial in determining the appropriate neoadjuvant treatment regimen. Adequate endoscopic restaging of rectal tumours after multimodality treatment will aid in selecting patients who are eligible for an organ preserving approach. The role and accuracy of imaging in the detection of the primary tumour, residual rectal cancer or local recurrence seems vital. Alternative neoadjuvant regimens are currently explored to increase the rate of clinical CRs, which may support organ preserving approaches. This review aims to generate insight into the advances in diagnostics and treatment modalities in all stages of rectal cancer and will highlight future studies that may support further implementation of organ preservation treatment in rectal cancer. Copyright © 2017 Elsevier Ltd, BASO ~ The Association for Cancer Surgery, and the European Society of Surgical Oncology. All rights reserved.

  19. Financial Burden Assessment in Patients With Stage I-III Colon or Rectal Cancer Undergoing Treatment

    ClinicalTrials.gov

    2018-06-12

    Stage I Colon Cancer AJCC v8; Stage I Rectal Cancer AJCC v8; Stage II Colon Cancer AJCC v8; Stage II Rectal Cancer AJCC v8; Stage IIA Colon Cancer AJCC v8; Stage IIA Rectal Cancer AJCC v8; Stage IIB Colon Cancer AJCC v8; Stage IIB Rectal Cancer AJCC v8; Stage IIC Colon Cancer AJCC v8; Stage IIC Rectal Cancer AJCC v8; Stage III Colon Cancer AJCC v8; Stage III Rectal Cancer AJCC v8; Stage IIIA Colon Cancer AJCC v8; Stage IIIA Rectal Cancer AJCC v8; Stage IIIB Colon Cancer AJCC v8; Stage IIIB Rectal Cancer AJCC v8; Stage IIIC Colon Cancer AJCC v8; Stage IIIC Rectal Cancer AJCC v8

  20. [Rectal endometriosis: An exceptional etiology of acute intestinal occlusion].

    PubMed

    Doh, Kwame; Thiam, Ibou; Ka, Sidy; Dial, Cherif; Woto-Gaye, Gisèle

    2016-12-01

    The intestinal occlusion acute is an emergency and therapeutic diagnostic. A rectal tumor is rarely the cause in a young adult. We are carrying the case of a patient of 43years old, received at emergency on a board of intestinal occlusion acute due to a rectal tumor of a fortuitous discovery during the operation. The final diagnosis after a histopathologic examination was for the less unexpected. It was rectal endometriosis in its tumor-like. A complementary medical care obtains satisfactory results. Copyright © 2016. Published by Elsevier Masson SAS.

  1. Defining the rectal dose constraint for permanent radioactive seed implantation of the prostate.

    PubMed

    Albert, Michele; Song, Jun S; Schultz, Delray; Cormack, Robert A; Tempany, Clare M; Haker, Steve; Devlin, Phillip M; Beard, Clair; Hurwitz, Mark D; Suh, Wonsuk W; Jolesz, Ferenc; D'Amico, Anthony V

    2008-01-01

    This study was performed to define the rectal dose constraint that would predict late rectal bleeding requiring argon plasma coagulation (APC) following prostate brachy mono-therapy. Between February 1999 and April 2002, 91 patients with low risk prostate cancer underwent permanent I(125) radioactive seed implantation without the use of supplemental external beam radiation or androgen suppression therapy. Patients received both CT and MRI scans 6 weeks postimplant for evaluation of dosimetry. The CT and MRI scans were fused. Rectal volumes were contoured on the T2 weighted MR images. For those patients requiring APC, the date on which a patient reported rectal bleeding was recorded. A Cox regression analysis was performed to assess whether there was a significant association between the rectal volume (continuous) exceeding 100 Gy time rectal bleeding. Comparisons of estimates of rectal bleeding requiring APC were made using a 2-sided log rank test. There was a significant association (hazard ratio = 5.6 [95% confidence interval: 1.3, 23.8]; P = 0.002) between the rectal volume exceeding 100 Gy and rectal bleeding requiring APC. After a median follow-up of 4.25 (1-6) years, no patient with less than a median value of 8 cc of rectum exceeding 100 Gy required APC, whereas 20% (P = 0.004) were estimated to require APC within 3 years following treatment. Keeping the rectal volume receiving more than 100 Gy below 8 cc will minimize the risk of rectal bleeding requiring APC following I(125) permanent prostate brachy mono-therapy.

  2. Talimogene Laherparepvec, Capecitabine, and Chemoradiation Before Surgery in Treating Patients With Locally Advanced or Metastatic Rectal Cancer

    ClinicalTrials.gov

    2018-04-30

    Rectal Adenocarcinoma; Stage III Rectal Cancer AJCC v7; Stage IIIA Rectal Cancer AJCC v7; Stage IIIB Rectal Cancer AJCC v7; Stage IIIC Rectal Cancer AJCC v7; Stage IV Rectal Cancer AJCC v7; Stage IVA Rectal Cancer AJCC v7; Stage IVB Rectal Cancer AJCC v7

  3. Coping with heat: function of the natal coat of cape fur seal (Arctocephalus Pusillus Pusillus) pups in maintaining core body temperature.

    PubMed

    Erdsack, Nicola; Dehnhardt, Guido; Hanke, Wolf

    2013-01-01

    Cape fur seal (Arctocephalus pusillus) pups spend the first weeks of life exclusively or mainly ashore. They are exposed to intense solar radiation and high temperatures for long time periods, which results in temperatures up to at least 80°C on their black natal coat. To test the hypothesis that the natal coat has a crucial function in coping with these extreme conditions, we investigated the insulating properties of the natal coat in six captive newborn Cape fur seals during the first 50 days after birth. The natal fur differs from the adult fur not only in colour, but also in density, structure, and water repellence. We measured temperature on the fur surface and within the fur, as well as skin and rectal temperature under varying environmental conditions, comparable to the species' habitat. Experiments were designed to not influence the spontaneous behaviour of the pups. Rectal temperature was constant as long as the pups stayed dry, even during long-lasting intense solar radiation for up to 3 h. Skin temperature remained close to rectal temperature as long as the fur was dry, while with wet fur, skin temperature was significantly reduced as well. Our results show that the natal coat provides an effective insulation against overheating. The severely reduced insulation of wet natal fur against cold supports the assumption that the natal fur is an adaptation to the pups' terrestrial phase of life.

  4. Coping with Heat: Function of The Natal Coat of Cape Fur Seal (Arctocephalus Pusillus Pusillus) Pups in Maintaining Core Body Temperature

    PubMed Central

    Erdsack, Nicola; Dehnhardt, Guido; Hanke, Wolf

    2013-01-01

    Cape fur seal (Arctocephalus pusillus) pups spend the first weeks of life exclusively or mainly ashore. They are exposed to intense solar radiation and high temperatures for long time periods, which results in temperatures up to at least 80°C on their black natal coat. To test the hypothesis that the natal coat has a crucial function in coping with these extreme conditions, we investigated the insulating properties of the natal coat in six captive newborn Cape fur seals during the first 50 days after birth. The natal fur differs from the adult fur not only in colour, but also in density, structure, and water repellence. We measured temperature on the fur surface and within the fur, as well as skin and rectal temperature under varying environmental conditions, comparable to the species' habitat. Experiments were designed to not influence the spontaneous behaviour of the pups. Rectal temperature was constant as long as the pups stayed dry, even during long-lasting intense solar radiation for up to 3 h. Skin temperature remained close to rectal temperature as long as the fur was dry, while with wet fur, skin temperature was significantly reduced as well. Our results show that the natal coat provides an effective insulation against overheating. The severely reduced insulation of wet natal fur against cold supports the assumption that the natal fur is an adaptation to the pups' terrestrial phase of life. PMID:23951287

  5. [Surgical treatment of pulmonary metastases from colon and rectal cancer].

    PubMed

    Togashi, Ken-ichi; Aoki, K; Hirahara, H; Sugawara, M; Oguma, F

    2004-09-01

    We retrospectively studied the surgical treatment for pulmonary metastases from colon and rectal cancer. A total of 24 patients (9 males and 15 females; mean age 61 years) underwent 29 thoracotomies for metastatic colon carcinoma, while 22 patients (16 males and 6 females; mean age 63 years) underwent 29 thoracotomies for metastatic rectal cancer. The median interval between the primary procedure and lung resection for metastases was 26 months in the patients with colon carcinoma and 32 months in the patients with rectal cancer. In the patients with colon carcinoma, 16 underwent wedge resection or segmentectomy (including 4 video-assisted procedures) and 13 (54%) underwent lobectomy or pneumonectomy. In the patients with rectal cancer, 15 underwent wedge or segmentectomy (including 1 video-assisted procedure), 13 (59%) underwent lobectomy or pneumonectomy, and 1 underwent exploratory thoracotomy. All procedures except exploratory thoracotomy were curative operations. There was no mortality. Overall 5-year survival was 56% (n=46). Five-year survival was 65% for patients with colon metastases (n=24) and 45% for patients with rectal metastases (n=22), and there was no significant difference. Recurrent sites were 4 lungs (36%), 4 livers (36%), 1 bone, 1 uterus, and 1 peritoneum in patients with colon carcimoma, and 10 lungs (43%), 5 brains (22%), 3 livers (13%), 1 bone, and 1 vagina in patients with rectal cancer. Pulmonary resection for metastases from colon carcinoma may have better prognosis than that from rectal cancer. However, further investigation may be required to obtain convincing conclusions.

  6. Measuring subcutaneous temperature and differential rates of rewarming from hibernation and daily torpor in two species of bats.

    PubMed

    Currie, Shannon E; Körtner, Gerhard; Geiser, Fritz

    2015-12-01

    Prolonged and remote measurement of body temperature (Tb) in undisturbed small hibernators was not possible in the past because of technological limitations. Although passive integrated transponders (PITs) have been used previously to measure subcutaneous temperature (Tsub) during daily torpor in a small marsupial, no study has attempted to use these devices at Tbs below 10°C. Therefore, we investigated whether subcutaneous interscapular PITs can be used as a viable tool for measuring Tb in a small hibernating bat (Nyctophilus gouldi; Ng) and compared it with measurements of Tb during daily torpor in a heterothermic bat (Syconycteris australis; Sa). The precision of transponders was investigated as a function of ambient temperature (Ta) and remote Tsub readings enabled us to quantify Tsub-Tb differentials during steady-state torpor and arousal. Transponders functioned well outside the manufacturer's recommended range, down to ~5°C. At rest, Tsub and rectal Tb (Trec) were strongly correlated for both bat species (Ng r(2)=0.88; Sa r(2)=0.95) and this was also true for N. gouldi in steady-state torpor (r(2)=0.93). During induced rewarming Tsub increased faster than Trec in both species. Our results demonstrate that transponders can be used to provide accurate remote measurement of Tb in two species of bats during different physiological states, both during steady-state conditions and throughout dynamic phases such as rewarming from torpor. We show that, at least during rewarming, regional heterothermy common to larger hibernators and other hibernating bats is also present in bats capable of daily torpor. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Body temperature responses of Savanna Brown goat to the harmattan and hot-dry season

    NASA Astrophysics Data System (ADS)

    Igono, M. O.; Molokwu, E. C. I.; Aliu, Y. O.

    1982-09-01

    Rectal and vaginal temperature responses of the Savanna Brown goat indigenous to the Nigerian guinea savanna were determined during the harmattan and the hot-dry season. Measurements were made at 06:00h and at 14:00h after 8h exposure to field conditions. At the 06:00h measurements during the harmattan, all animals were observed to shiver. A significant (P<0.01) positive correlation was found between rectal (Tre) and vaginal temperatures. During the harmattan, mean Tre was 38.2‡C at 06:00h and 39.7‡C at 14:00h; the mean difference, δTre was 1.5‡C. During the hot-dry season, Tre at 06:00h was 38.1‡C, and at 14:00h, 38.7; δTre was 0.6‡C. It is concluded that the harmattan is thermally more stressful than the hot-dry season and that passive thermolability may not be an important mechanism in the Savanna Brown goat in adaptation to thermal stress.

  8. Noncontact true temperature measurement, 2

    NASA Technical Reports Server (NTRS)

    Lee, Mark C.; Allen, James L.

    1988-01-01

    A laser pyrometer was developed for acquiring the true temperature of a levitated sample. The reflectivity is measured by first expanding the laser beam to cover the entire cross-sectional surface of the diffuse target. The reflectivity calibration of this system is determined from the surface emissivity of a target with a blackbody cavity. The emissivity of the real target can then be calculated. The overall system constant is obtained by passively measuring the radiance of the blackbody cavity (emissivity = 1.0) at a known, arbitrary temperature. Since the photosensor used is highly linear over the entire operating temperature range, the true temperature of the target can then be computed. The latest results available from this on-going research indicate that true temperatures thus obtained are in very good quantitative agreement with thermocouple measured temperatures.

  9. Disturbances in Pro-Oxidant-Antioxidant Balance after Passive Body Overheating and after Exercise in Elevated Ambient Temperatures in Athletes and Untrained Men

    PubMed Central

    Pilch, Wanda; Szygula, Zbigniew; Tyka, Anna K.; Palka, Tomasz; Tyka, Aleksander; Cison, Tomasz; Pilch, Pawel; Teleglow, Aneta

    2014-01-01

    The aim of the study was to investigate pro-oxidant-antioxidant balance in two series of examinations with two types of stressors (exogenous heat and the combined exogenous and endogenous heat) in trained and untrained men. The exogenous stressor was provided by Finnish sauna session, whereas the combined stressor was represented by the exercise in elevated ambient temperature. The men from the two groups performed the physical exercise on a cycle ergometer with the load of 53±2% maximal oxygen uptake at the temperature of 33±1°C and relative humidity of 70% until their rectal temperature rose by 1.2°C. After a month from completion of the exercise test the subjects participated in a sauna bathing session with the temperature of 96±2°C, and relative humidity of 16±5%. 15-minutes heating and 2-minute cool-down in a shower with the temperature of 20°C was repeated until rectal temperature rose by 1.2°C compared to the initial value. During both series of tests rectal temperature was measured at 5-minute intervals. Before both series of tests and after them body mass was measured and blood samples were taken for biochemical tests. Serum total protein, serum concentration of lipid peroxidation products and serum antioxidants were determined. The athletes were characterized by higher level of antioxidant status and lower concentration of lipid peroxidation products. Physical exercise at elevated ambient temperature caused lower changes in oxidative stress indices compared to sauna bathing. Sauna induced a shift in pro-oxidant-antioxidant balance towards oxidation, which was observed less intensively in the athletes compared to the untrained men. This leads to the conclusion that physical exercise increases tolerance to elevated ambient temperature and oxidative stress. PMID:24465535

  10. Umbilical metastasis derived from early stage rectal cancer: a case report

    PubMed Central

    2014-01-01

    Background Umbilical metastasis, also called Sister Mary Joseph’s nodule (SMJN), is defined as the umbilical nodule associated with advanced metastatic intra-abdominal and pelvic malignancies. A patient with umbilical metastasis has been deemed to have a poor prognosis. Rectal cancer presenting with a SMJN is a rare phenomenon, especially in the early stage and in middle-low rectal cancer. Case presentation We report a case of a 70-year-old male presenting with umbilical metastasis derived from rectal cancer (10 cm from the anal verge, T2N0). Discussion and conclusion For rectal cancer with umbilical metastasis, the exact metastatic routes as well as the criterion of diagnosis and treatments are not very clear. Here we review the literature on rectal cancer and SMJN to deepen the understanding of this disease. PMID:24708697

  11. Lamellipodin-Deficient Mice: A Model of Rectal Carcinoma

    PubMed Central

    Miller, Cassandra L.; Muthupalani, Sureshkumar; Shen, Zeli; Drees, Frauke; Ge, Zhongming; Feng, Yan; Chen, Xiaowei; Gong, Guanyu; Nagar, Karan K.; Wang, Timothy C.; Gertler, Frank B.; Fox, James G.

    2016-01-01

    During a survey of clinical rectal prolapse (RP) cases in the mouse population at MIT animal research facilities, a high incidence of RP in the lamellipodin knock-out strain, C57BL/6-Raph1tm1Fbg (Lpd-/-) was documented. Upon further investigation, the Lpd-/- colony was found to be infected with multiple endemic enterohepatic Helicobacter species (EHS). Lpd-/- mice, a transgenic mouse strain produced at MIT, have not previously shown a distinct immune phenotype and are not highly susceptible to other opportunistic infections. Predominantly male Lpd-/- mice with RP exhibited lesions consistent with invasive rectal carcinoma concomitant to clinically evident RP. Multiple inflammatory cytokines, CD11b+Gr1+ myeloid-derived suppressor cell (MDSC) populations, and epithelial cells positive for a DNA damage biomarker, H2AX, were elevated in affected tissue, supporting their role in the neoplastic process. An evaluation of Lpd-/- mice with RP compared to EHS-infected, but clinically normal (CN) Lpd-/- animals indicated that all of these mice exhibit some degree of lower bowel inflammation; however, mice with prolapses had significantly higher degree of focal lesions at the colo-rectal junction. When Helicobacter spp. infections were eliminated in Lpd-/- mice by embryo transfer rederivation, the disease phenotype was abrogated, implicating EHS as a contributing factor in the development of rectal carcinoma. Here we describe lesions in Lpd-/- male mice consistent with a focal inflammation-induced neoplastic transformation and propose this strain as a mouse model of rectal carcinoma. PMID:27045955

  12. Study of the role of the transverse perineal muscles during rectal filling.

    PubMed

    Shafik, Ahmed; Shafik, Ali A; Shafik, Ismail; El-Sibai, Olfat

    2006-10-01

    The function of perineal muscles at defecation is poorly addressed in the literature. We investigated the hypothesis that rectal distension effects reflex contraction of four perineal muscles. After rectal balloon distension with carbon dioxide in increments of 20 ml, the responses of electromyographic (EMG) activity of superficial (STPM) and deep (DTPM) transverse perineal muscles as well as the rectal pressure were recorded in 22 healthy volunteers (14 men, age 37.2+/-6.3 years). Responses were registered again after individual anesthetization of rectum and transverse perineal muscles. Tests were repeated using saline instead of lidocaine. Rectal balloon distension in big volumes effected increase of the transverse perineal muscles' EMG activity and rectal pressure. The more the rectum was distended, the more the rectal pressure and EMG activity of the transverse perineal muscles were increased. The latency showed a gradual decrease upon incremental rectal distension increase. Transverse perineal muscles did not respond to rectal distension after the rectum and perineal muscles had been individually anesthetized, but it responded to saline administration. Response of the muscles was similar in both sides. Increase of rectal pressure increases EMG activity of transverse perineal muscles. This action seems mediated through a reflex which we call 'recto-perineal reflex'. Contraction of transverse perineal muscles at defecation presumably supports the perineal floor. It also protects transverse perineal muscles against straining-produced high pressure that is transmitted through the recto-vaginal/-vesical cul de sac to the perineum which may sag down and share in genesis of perineocele, enterocele, or sigmoidocele.

  13. Penetrating bladder trauma: a high risk factor for associated rectal injury.

    PubMed

    Pereira, B M; Reis, L O; Calderan, T R; de Campos, C C; Fraga, G P

    2014-01-01

    Demographics and mechanisms were analyzed in prospectively maintained level one trauma center database 1990-2012. Among 2,693 trauma laparotomies, 113 (4.1%) presented bladder lesions; 51.3% with penetrating injuries (n = 58); 41.3% (n = 24) with rectal injuries, males corresponding to 95.8%, mean age 29.8 years; 79.1% with gunshot wounds and 20.9% with impalement; 91.6% arriving the emergence room awake (Glasgow 14-15), hemodynamically stable (average systolic blood pressure 119.5 mmHg); 95.8% with macroscopic hematuria; and 100% with penetrating stigmata. Physical exam was not sensitive for rectal injuries, showing only 25% positivity in patients. While 60% of intraperitoneal bladder injuries were surgically repaired, extraperitoneal ones were mainly repaired using Foley catheter alone (87.6%). Rectal injuries, intraperitoneal in 66.6% of the cases and AAST-OIS grade II in 45.8%, were treated with primary suture plus protective colostomy; 8.3% were sigmoid injuries, and 70.8% of all injuries had a minimum stool spillage. Mean injury severity score was 19; mean length of stay 10 days; 20% of complications with no death. Concomitant rectal injuries were not a determinant prognosis factor. Penetrating bladder injuries are highly associated with rectal injuries (41.3%). Heme-negative rectal examination should not preclude proctoscopy and eventually rectal surgical exploration (only 25% sensitivity).

  14. A survey on rectal bleeding in children, a report from Iran

    PubMed

    Dehghani, Seyed Mohsen; Shahramian, Iraj; Ataollahi, Maryam; Bazı, Ali; Seirfar, Nosaibe; Delaramnasab, Mojtaba; Sargazi, Alireza; Shariatrazavi, Mahsa

    2018-04-30

    Background/aim: Studies on the epidemiology of rectal bleeding in children are limited in Iran. Our aim was to assess etiologies of rectal bleeding in children in Iran. Materials and methods: We enrolled 730 children with rectal bleeding. All the patients underwent colonoscopy, and 457 were further evaluated with histopathology. Results: According to colonoscopy and histopathology, respectively, inflammatory bowel disease (IBD) (29.4%, 15.8%), nodular hyperplasia (NH) (24.9%, 10%), and juvenile polyposis (JP) (12.6%, 9.9%) were the most common causes of rectal bleeding. Other conditions were solitary rectal ulcer (5.3%), chronic colitis (4.6%), allergic colitis (3.3%), focal colitis (1.3%), and infectious colitis (1.1%). In colonoscopy, there were no significant differences in the distribution of pathologies regarding sex, while the youngest and oldest mean ages were found for patients with NH (4.6 ± 3.9 years, P < 0.0001) and those with normal appearance (8.1 ± 4.4 years, P < 0.0001) respectively. Based on histopathologic reports, the youngest patients were diagnosed with infectious colitis (4.6 ± 2.8 years), while patients with chronic colitis were the oldest (9.2 ± 4.6 years, P = 0.003). Conclusion: JP, NH, and IBD constituted the most common etiologies of rectal bleeding in our patients. It is recommended to perform a complete diagnostic approach to accurately assess rectal bleeding in children.

  15. Evaluation of the Rectal Cancer Patient Decision Aid: A Before and After Study.

    PubMed

    Wu, Robert Chi; Boushey, Robin Paul; Scheer, Adena Sarah; Potter, Beth; Moloo, Husein; Auer, Rebecca; Tadros, Shaheer; Roberts, Patricia; Stacey, Dawn

    2016-03-01

    In rectal cancer surgery, low anterior resection and abdominoperineal resection have equivocal impact on overall quality of life. A rectal cancer decision aid was developed to help patients weigh features of options and share their preference. The aim of this study was to evaluate the effect of a patient decision aid for mid to low rectal cancer surgery on the patients' choice and decision-making process. A before-and-after study was conducted. Baseline data collection occurred after surgeon confirmation of eligibility at the first consultation. Patients used the patient decision aid at home (online and/or paper-based formats) and completed post questionnaires. This study was conducted at an academic hospital referral center. Adults who had rectal cancer at a maximum of 10 cm proximal to the anal verge and were amenable to surgical resection were considered. Those with preexisting stoma and those only receiving abdominoperineal resection for technical reasons were excluded from the study. Patient with rectal cancer were provided with a decision aid. The primary outcomes measured were decisional conflict, knowledge, and preference for a surgical option. Of 136 patients newly diagnosed with rectal cancer over 13 months, 44 (32.4%) were eligible, 36 (81.9%) of the eligible patients consented to participate, and 32 (88.9%) patients completed the study. The mean age of participants was 61.9 ± 9.7 years and tumor location was on average 7.3 ± 2.1 cm above the anal verge. Patients had poor baseline knowledge (52.5%), and their knowledge improved by 37.5% (p < 0.0001) after they used the patient decision aid. Decisional conflict was reduced by 24.2% (p = 0.0001). At baseline, no patients preferred a permanent stoma, and after decision aid exposure, 2 patients (7.1%) preferred permanent stoma. Over 96% of participants would recommend the patient decision aid to others. This study was limited by the lack of control for potential confounders and potential response bias. The

  16. Genome-Wide Association Mapping for Identification of Quantitative Trait Loci for Rectal Temperature during Heat Stress in Holstein Cattle

    PubMed Central

    Dikmen, Serdal; Cole, John B.; Null, Daniel J.; Hansen, Peter J.

    2013-01-01

    Heat stress compromises production, fertility, and health of dairy cattle. One mitigation strategy is to select individuals that are genetically resistant to heat stress. Most of the negative effects of heat stress on animal performance are a consequence of either physiological adaptations to regulate body temperature or adverse consequences of failure to regulate body temperature. Thus, selection for regulation of body temperature during heat stress could increase thermotolerance. The objective was to perform a genome-wide association study (GWAS) for rectal temperature (RT) during heat stress in lactating Holstein cows and identify SNPs associated with genes that have large effects on RT. Records on afternoon RT where the temperature-humidity index was ≥78.2 were obtained from 4,447 cows sired by 220 bulls, resulting in 1,440 useable genotypes from the Illumina BovineSNP50 BeadChip with 39,759 SNP. For GWAS, 2, 3, 4, 5, and 10 adjacent SNP were averaged to identify consensus genomic regions associated with RT. The largest proportion of SNP variance (0.07 to 0.44%) was explained by markers flanking the region between 28,877,547 and 28,907,154 bp on Bos taurus autosome (BTA) 24. That region is flanked by U1 (28,822,883 to 28,823,043) and NCAD (28,992,666 to 29,241,119). In addition, the SNP at 58,500,249 bp on BTA 16 explained 0.08% and 0.11% of the SNP variance for 2- and 3-SNP analyses, respectively. That contig includes SNORA19, RFWD2 and SCARNA3. Other SNPs associated with RT were located on BTA 16 (close to CEP170 and PLD5), BTA 5 (near SLCO1C1 and PDE3A), BTA 4 (near KBTBD2 and LSM5), and BTA 26 (located in GOT1, a gene implicated in protection from cellular stress). In conclusion, there are QTL for RT in heat-stressed dairy cattle. These SNPs could prove useful in genetic selection and for identification of genes involved in physiological responses to heat stress. PMID:23935954

  17. Balloon-Occluded Antegrade Transvenous Sclerotherapy to Treat Rectal Varices: A Direct Puncture Approach to the Superior Rectal Vein Through the Greater Sciatic Foramen Under CT Fluoroscopy Guidance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ono, Yasuyuki, E-mail: onoyasy@hirakata.kmu.ac.jp; Kariya, Shuji, E-mail: kariyas@hirakata.kmu.ac.jp; Nakatani, Miyuki, E-mail: nakatanm@hirakata.kmu.ac.jp

    Rectal varices occur in 44.5 % of patients with ectopic varices caused by portal hypertension, and 48.6 % of these patients are untreated and followed by observation. However, bleeding occurs in 38 % and shock leading to death in 5 % of such patients. Two patients, an 80-year-old woman undergoing treatment for primary biliary cirrhosis (Child-Pugh class A) and a 63-year-old man with class C hepatic cirrhosis (Child-Pugh class A), in whom balloon-occluded antegrade transvenous sclerotherapy was performed to treat rectal varices are reported. A catheter was inserted by directly puncturing the rectal vein percutaneously through the greater sciatic foramen under computed tomographic fluoroscopymore » guidance. In both cases, the rectal varices were successfully treated without any significant complications, with no bleeding from rectal varices after embolization.« less

  18. Rectal absorption of diazepam in epileptic children.

    PubMed Central

    Dhillon, S; Ngwane, E; Richens, A

    1982-01-01

    The absorption of diazepam after rectal administration was studied in children with epilepsy. When given as a solution, diazepam was rapidly absorbed and produced serum diazepam concentrations above 200 ng/ml within 10 minutes in most children. However, a commercial suppository formulation was absorbed slowly and cannot be recommended for urgent treatment of fits. There is a need in the UK for a rapidly absorbed preparation of diazepam which is approved for rectal use. PMID:7082038

  19. Silicone rubber band treatment of rectal prolapse.

    PubMed

    Jackaman, F R; Francis, J N; Hopkinson, B R

    1980-09-01

    Fifty-two patients with rectal prolapse have been treated by the silicone rubber band perianal suture technique and satisfactory results have been obtained in 46 (89%). Eleven patients required reoperation to achieve this result. The procedure is a minor one, with little morbidity and no mortality. Provided that faecal impaction can be avoided in patients having this operation a successful outcome, can be expected. It is recommended especially for the frail and elderly with rectal prolapse.

  20. Silicone rubber band treatment of rectal prolapse.

    PubMed Central

    Jackaman, F. R.; Francis, J. N.; Hopkinson, B. R.

    1980-01-01

    Fifty-two patients with rectal prolapse have been treated by the silicone rubber band perianal suture technique and satisfactory results have been obtained in 46 (89%). Eleven patients required reoperation to achieve this result. The procedure is a minor one, with little morbidity and no mortality. Provided that faecal impaction can be avoided in patients having this operation a successful outcome, can be expected. It is recommended especially for the frail and elderly with rectal prolapse. PMID:7002011

  1. An unusual case of mesalazine intoxication: oral and rectal overloading of the rectal suppository form.

    PubMed

    Koseoglu, Zikret; Satar, Salim; Kara, Banu; Sebe, Ahmet; Kosenli, Ozgun

    2011-07-01

    Drugs containing 5-acetylsalicylic acid (5-ASA) have been commonly used for inflammatory bowel diseases for more than half a century, but no case about overdose of suppository form of mesalazine which was taken both orally and rectally has been reported in the related literature up to now. In the present case, a 20-year-old male patient who took 14.5 g of mesalazine rectally and orally for suicide purpose is discussed. He was an ulcerative colitis patient and depressed about his illness and routine life traffic. Although it was hard for him to take the suppository form orally because of its bad taste and structure, he took it with the help of water. In the patient's colonoscopy, diffuse hyperemia and edema extending from the anal channel to the proximal rectal mucosa and a 1.5 cm diameter ulcer expanding from anal channel through the rectum were identified. No pathology was found in the upper gastrointestinal endoscopy. Routine laboratory examination was performed and no abnormality was identified in the patient's total blood account, biochemical parameters and full-urine examination. In the control rectoscopy applied to the patient 15 days later, recovery of the ulcer was observed and he was discharged to be followed in the psychiatry clinic.

  2. Thermospheric temperature measurement technique.

    NASA Technical Reports Server (NTRS)

    Hueser, J. E.; Fowler, P.

    1972-01-01

    A method for measurement of temperature in the earth's lower thermosphere from a high-velocity probes is described. An undisturbed atmospheric sample is admitted to the instrument by means of a free molecular flow inlet system of skimmers which avoids surface collisions of the molecules prior to detection. Measurement of the time-of-flight distribution of an initially well-localized group of nitrogen metastable molecular states produced in an open, crossed electron-molecular beam source, yields information on the atmospheric temperature. It is shown that for high vehicle velocities, the time-of-flight distribution of the metastable flux is a sensitive indicator of atmospheric temperature. The temperature measurement precision should be greater than 94% at the 99% confidence level over the range of altitudes from 120-170 km. These precision and altitude range estimates are based on the statistical consideration of the counting rates achieved with a multichannel analyzer using realistic values for system parameters.

  3. Temperature Measurement Aid

    NASA Technical Reports Server (NTRS)

    1979-01-01

    NASA's Ames Research Center has designed a simple but medically important device--one which holds temperature probes, called thermistors, to a person's skin without affecting the characteristics of the skin segment being measured. The device improves the accuracy of skin surface temperature measurements, valuable data in health evaluation. The need for such a device was recognized in the course of life science experiments at Ames. In earlier methods, the sensing head of the temperature probe was affixed to the patient's skin by tape or elastic bands. This created a heat variance which altered skin temperature readings. The Ames-developed thermistor holder is a plastic ring with tab extensions, shown in the upper photo on the chest, arm and leg of the patient undergoing examination. The ring holds the sensing head of the temperature probe and provides firm, constant pressure between the skin and the probe. The tabs help stabilize the ring and provide attachment points for the fastening tape or bands, which do not directly touch the sensor. With this new tool, it is possible to determine more accurately the physiological effects of strenuous exercise, particularly on the treadmill. The holder is commercially available from Yellow Springs Instrument Company, Inc., Yellow Springs, Ohio, which is producing the device under a NASA patent license.

  4. Thermosensitive and mucoadhesive in situ gel based on poloxamer as new carrier for rectal administration of nimesulide.

    PubMed

    Yuan, Yuan; Cui, Ying; Zhang, Li; Zhu, Hui-Ping; Guo, Yi-Sha; Zhong, Bo; Hu, Xia; Zhang, Ling; Wang, Xiao-Hui; Chen, Li

    2012-07-01

    Poloxamer 407 has excellent thermo-sensitive gelling properties. Nevertheless, these gels possess inadequate poor bioadhesiveness and high permeability to water, which limited its' application as a thermoresponsive matrix. The main aim of the present investigation was to develop thermosensitive and mucoadhesive rectal in situ gel of nimesulide (NM) by using mucoadhesive polymers such as sodium alginate (Alg-Na) and HPMC. These gels were prepared by addition of mucoadhesive polymers (0.5%) to the formulations of thermosensitive gelling solution containing poloxamer 407 (18%) and nimesulide (2.0%). Polyethylene glycol (PEG) was used to modify gelation temperature and drug release properties. The gelation temperature and drug release rate of the prepared in situ gels were evaluated. Gelation temperature was significantly increased with incorporation of nimesulide (2.0%) in the poloxamer solution, while the addition of the mucoadhesive polymers played a reverse role on gelation temperature. The addition of PEG polymers increased the gelation temperature and the drug release rate. Among the formulations examined, the poloxamer 407/nimesulide/sodium alginate/PEG 4000 (18/2.0/0.5/1.2%) exhibited the appropriate gelation temperature, acceptable drug release rate and rectal retention at the administration site. Furthermore, the micrographic results showed that in situ gel, given at the dose of 20mg/kg, was safe for no mucosa irritation. In addition, it resulted in significantly higher initial serum concentrations, C(max) and AUC of NM compared to the solid suppository. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. Relative bioavailability, metabolism and tolerability of rectally administered oxcarbazepine suspension.

    PubMed

    Clemens, Pamela L; Cloyd, James C; Kriel, Robert L; Remmel, Rory P

    2007-01-01

    Maintenance of effective drug concentrations is essential for adequate treatment of epilepsy. Some antiepileptic drugs can be successfully administered rectally when the oral route of administration is temporarily unavailable. Oxcarbazepine is a newer antiepileptic drug that is rapidly converted to a monohydroxy derivative, the active compound. This study aimed to characterise the bioavailability, metabolism and tolerability of rectally administered oxcarbazepine suspension using a randomised, crossover design in ten healthy volunteers. Two subjects received 300 mg doses of oxcarbazepine suspension via rectal and oral routes and eight received 450 mg doses. A washout period of at least 2 weeks elapsed between doses. The rectal dose was diluted 1:1 with water. Blood samples and urine were collected for 72 hours post-dose. Adverse effects were assessed at each blood collection time-point using a self-administered questionnaire. Plasma was assayed for oxcarbazepine and monohydroxy derivative; urine was assayed for monohydroxy derivative and monohydroxy derivative-glucuronide. Maximum plasma concentration (C(max)) and time to reach C(max) (t(max)) were obtained directly from the plasma concentration-time curves. The areas under the concentration-time curve (AUCs) were determined via non-compartmental analysis. Relative bioavailability was calculated and the C(max) and AUCs were compared using Wilcoxon signed-rank tests. Mean relative bioavailability calculated from plasma AUCs was 8.3% (SD 5.5%) for the monohydroxy derivative and 10.8% (SD 7.3%) for oxcarbazepine. Oxcarbazepine and monohydroxy derivative C(max) and AUC values were significantly lower following rectal administration (p < 0.01). The total amount of monohydroxy derivative excreted in the urine following rectal administration was 10 +/- 5% of the amount excreted following oral administration. Oral absorption was consistent with previous studies. The most common adverse effects were headache and fatigue

  6. Gastric heterotopia of rectum in a child: a mimicker of solitary rectal ulcer syndrome.

    PubMed

    Al-Hussaini, Abdulrahman; Lone, Khurram; Al-Sofyani, Medhat; El Bagir, Asim

    2014-01-01

    Bleeding per rectum is an uncommon presentation in pediatric patients. Heterotopic gastric mucosa in the rectum is a rare cause of rectal bleeding. Here, we report a 3-year-old child with a bleeding rectal ulcer that was initially diagnosed and managed as a solitary rectal ulcer syndrome. After 1 month, the patient persisted to have intermittent rectal bleed and severe anal pain. Repeat colonoscopy showed the worsening of the rectal ulcer in size. Pediatric surgeon excised the ulcer, and histopathological examination revealed a gastric fundic-type mucosa consistent with the diagnosis of gastric heterotopia of the rectum. Over the following 18 months, our patient had experienced no rectal bleeding and remained entirely asymptomatic. In conclusion, heterotopic gastric mucosa of the rectum should be considered in the differential diagnosis of a bleeding rectal ulcer.

  7. Development of a rectal sexually transmitted infection (STI) Model in Rhesus macaques using Chlamydia trachomatis serovars E and L2.

    PubMed

    Henning, Tara R; Morris, Monica; Ellis, Shanon; Kelley, Kristen; Phillips, Christi; Ritter, Jana; Jones, Tara; Nachamkin, Eli; Chen, Cheng Y; Hong, Jaeyoung; Kang, Joseph; Patton, Dorothy; McNicholl, Janet; Papp, John; Kersh, Ellen N

    2017-10-01

    Rectal STI coinfection models enhance the understanding of rectal HIV transmission risk factors. Rhesus macaques (n=9) were exposed to one of three rectal Chlamydia trachomatis (CT) challenges: C. trachomatis L 2 (CT-L 2 ); C. trachomatis serovar E (CT-E), followed by CT-L 2 ; or CT-E, treatment/clearance, then CT-L 2 . Infections were monitored by PCR. Weekly blood and rectal secretion/lavage samples were collected for cytokine analyzes and/or epithelial sloughing, occult, and overt blood determinations. Chlamydial infections were successfully established in each animal, with varying degrees of persistence. Mucosal IL-1beta was upregulated in animals consecutively infected with CT-E then CT-L 2 (P=.05). Epithelial sloughing was also significantly increased post-infection in this group (P=.0003). This study demonstrates successful rectal infection of rhesus macaques with CT-E and CT-L 2 and describes measures of assessing rectal inflammation and pathology. Different infection strategies yield varying inflammatory and pathologic outcomes, providing well-described models for future SIV/SHIV susceptibility studies. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Polyethylene glycol hydrogel rectal spacer implantation in patients with prostate cancer undergoing combination high-dose-rate brachytherapy and external beam radiotherapy.

    PubMed

    Yeh, Jekwon; Lehrich, Brandon; Tran, Carolyn; Mesa, Albert; Baghdassarian, Ruben; Yoshida, Jeffrey; Torrey, Robert; Gazzaniga, Michael; Weinberg, Alan; Chalfin, Stuart; Ravera, John; Tokita, Kenneth

    2016-01-01

    To present rectal toxicity rates in patients administered a polyethylene glycol (PEG) hydrogel rectal spacer in conjunction with combination high-dose-rate brachytherapy and external beam radiotherapy. Between February 2010 and April 2015, 326 prostate carcinoma patients underwent combination high-dose-rate brachytherapy of 16 Gy (average dose 15.5 Gy; standard deviation [SD] = 1.6 Gy) and external beam radiotherapy of 59.4 Gy (average dose 60.2 Gy; SD = 2.9 Gy). In conjunction with the radiation therapy regimen, each patient was injected with 10 mL of a PEG hydrogel in the anterior perirectal fat space. The injectable spacer (rectal spacer) creates a gap between the prostate and the rectum. The rectum is displaced from the radiation field, and rectal dose is substantially reduced. The goal is a reduction in rectal radiation toxicity. Clinical efficacy was determined by measuring acute and chronic rectal toxicity using the National Cancer Center Institute Common Terminology Criteria for Adverse Events v4.0 grading scheme. Median followup was 16 months. The mean anterior-posterior separation achieved was 1.6 cm (SD = 0.4 cm). Rates of acute Grade 1 and 2 rectal toxicity were 37.4% and 2.8%, respectively. There were no acute Grade 3/4 toxicities. Rates of late Grade 1, 2, and 3 rectal toxicity were 12.7%, 1.4%, and 0.7%, respectively. There were no late Grade 4 toxicities. PEG rectal spacer implantation is safe and well tolerated. Acute and chronic rectal toxicities are low despite aggressive dose escalation. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  9. Multimodal imaging evaluation in staging of rectal cancer

    PubMed Central

    Heo, Suk Hee; Kim, Jin Woong; Shin, Sang Soo; Jeong, Yong Yeon; Kang, Heoung-Keun

    2014-01-01

    Rectal cancer is a common cancer and a major cause of mortality in Western countries. Accurate staging is essential for determining the optimal treatment strategies and planning appropriate surgical procedures to control rectal cancer. Endorectal ultrasonography (EUS) is suitable for assessing the extent of tumor invasion, particularly in early-stage or superficial rectal cancer cases. In advanced cases with distant metastases, computed tomography (CT) is the primary approach used to evaluate the disease. Magnetic resonance imaging (MRI) is often used to assess preoperative staging and the circumferential resection margin involvement, which assists in evaluating a patient’s risk of recurrence and their optimal therapeutic strategy. Positron emission tomography (PET)-CT may be useful in detecting occult synchronous tumors or metastases at the time of initial presentation. Restaging after neoadjuvant chemoradiotherapy (CRT) remains a challenge with all modalities because it is difficult to reliably differentiate between the tumor mass and other radiation-induced changes in the images. EUS does not appear to have a useful role in post-therapeutic response assessments. Although CT is most commonly used to evaluate treatment responses, its utility for identifying and following-up metastatic lesions is limited. Preoperative high-resolution MRI in combination with diffusion-weighted imaging, and/or PET-CT could provide valuable prognostic information for rectal cancer patients with locally advanced disease receiving preoperative CRT. Based on these results, we conclude that a combination of multimodal imaging methods should be used to precisely assess the restaging of rectal cancer following CRT. PMID:24764662

  10. The effects of a tranquilizer on body temperature.

    DOT National Transportation Integrated Search

    1963-10-01

    Four young adult mongrel dogs were exposed twice untranquilized to each of three environmental temperatures: 4.4C, 23.9C, and 37.8C and exposed twice tranquilized with 2.2 mg/Kg propiopromazine hydrochloride. Rectal temperatures were monitored ...

  11. Transanal endoscopic microsurgery versus endoscopic mucosal resection for large rectal adenomas (TREND-study)

    PubMed Central

    van den Broek, Frank JC; de Graaf, Eelco JR; Dijkgraaf, Marcel GW; Reitsma, Johannes B; Haringsma, Jelle; Timmer, Robin; Weusten, Bas LAM; Gerhards, Michael F; Consten, Esther CJ; Schwartz, Matthijs P; Boom, Maarten J; Derksen, Erik J; Bijnen, A Bart; Davids, Paul HP; Hoff, Christiaan; van Dullemen, Hendrik M; Heine, G Dimitri N; van der Linde, Klaas; Jansen, Jeroen M; Mallant-Hent, Rosalie CH; Breumelhof, Ronald; Geldof, Han; Hardwick, James CH; Doornebosch, Pascal G; Depla, Annekatrien CTM; Ernst, Miranda F; van Munster, Ivo P; de Hingh, Ignace HJT; Schoon, Erik J; Bemelman, Willem A; Fockens, Paul; Dekker, Evelien

    2009-01-01

    Background Recent non-randomized studies suggest that extended endoscopic mucosal resection (EMR) is equally effective in removing large rectal adenomas as transanal endoscopic microsurgery (TEM). If equally effective, EMR might be a more cost-effective approach as this strategy does not require expensive equipment, general anesthesia and hospital admission. Furthermore, EMR appears to be associated with fewer complications. The aim of this study is to compare the cost-effectiveness and cost-utility of TEM and EMR for the resection of large rectal adenomas. Methods/design Multicenter randomized trial among 15 hospitals in the Netherlands. Patients with a rectal adenoma ≥ 3 cm, located between 1–15 cm ab ano, will be randomized to a TEM- or EMR-treatment strategy. For TEM, patients will be treated under general anesthesia, adenomas will be dissected en-bloc by a full-thickness excision, and patients will be admitted to the hospital. For EMR, no or conscious sedation is used, lesions will be resected through the submucosal plane in a piecemeal fashion, and patients will be discharged from the hospital. Residual adenoma that is visible during the first surveillance endoscopy at 3 months will be removed endoscopically in both treatment strategies and is considered as part of the primary treatment. Primary outcome measure is the proportion of patients with recurrence after 3 months. Secondary outcome measures are: 2) number of days not spent in hospital from initial treatment until 2 years afterwards; 3) major and minor morbidity; 4) disease specific and general quality of life; 5) anorectal function; 6) health care utilization and costs. A cost-effectiveness and cost-utility analysis of EMR against TEM for large rectal adenomas will be performed from a societal perspective with respectively the costs per recurrence free patient and the cost per quality adjusted life year as outcome measures. Based on comparable recurrence rates for TEM and EMR of 3.3% and

  12. Kinetics of absorption and elimination of ofloxacin in humans after oral and rectal administrations.

    PubMed

    Eboka, C J; Okor, R S; Akerele, J O; Aigbavboa, S O

    1997-06-01

    Ofloxacin pharmacokinetics have been studied in four healthy subjects after a single oral or rectal dose, each of 200 mg. For the oral dose tmax was about 2 h, Cmax 1.96 +/- 0.56 micrograms/ml and AUC1-15 15.22 micrograms/ml.h. Two-phase elimination pharmacol kinetics were observed for the oral dose, t1/2 for the rapid elimination phase was 3.3 h and for the slow phase 10 h. With the rectal dose tmax was 6 h, Cmax 0.71 +/- 0.44 microgram/ml and AUC0-15 7.58 micrograms/ml.h. The relative rectal bioavailability (AUC rectal/AUC oral) was 49.8%. Elimination rate of the rectal dose was generally slow (t1/2 = 9 h), an observation attributable to the sustained-release effect of the rectal suppository base, PEG 6000. The indication is that the rectal formulation cannot be substituted totally for the oral without first increasing the rectal dose; the 200 mg suppository can however be employed as a follow-up therapy to the oral dose in certain situations.

  13. [Transanal endocopic microsurgery (TEM) in advanced rectal cancer disease treatment].

    PubMed

    Paci, Marcello; Scoglio, Daniele; Ursi, Pietro; Barchetti, Luciana; Fabiani, Bernardina; Ascoli, Giada; Lezoche, Giovanni

    2010-01-01

    After Heald's revolution in 1982, who introduced the total mesorectal excision, for improve the results in terms of recurrance and survival rate, there is a need to explore new therapeutic options in treatment of sub-peritoneal rectal cancer. In particular, local excision represent more often a valid technique for non advanced rectal cancer treatment in comparison with the more invasive procedure, especially in elderly and/or in poor health patients. The introduction of TEM by Buess (transanal endoscopy microsurgery), has extended the local treatment also to classes of patients who would normally have been candidates for TME. The author gives literature's details and his experience in the use of TEM for early rectal cancer sub-peritoneal. The aim of the study is to analyze short and long term results in terms of local recurrence and survival rate comparing TEM technique with the other transanal surgery in rectal cancer treatment. Preoperative Chemio-Radio therapy and rigorous Imaging Staging are the first steps to planning surgery. It's time, for local rectal cancer, has come to make the devolution a few decades ago has been accomplished in the treatment of breast cancer

  14. [NOTES ASSISTED ENDOLUMENAL RECTAL RESECTION AND SPECIMEN EXTRACTION WITHOUT RECTAL STUMP OPENING - OUR EXPERIENCE WITH THIS NOVEL TECHNIQUE IN A PORCINE MODEL].

    PubMed

    Kvasha, Anton; Rosenthal, Eyal; Khalifa, Muhammad; Waksman, Igor

    2017-05-01

    Laparoscopic surgery has long been used for colon and rectal resection, and the laparoscopic-assisted approach has prevailed in surgical practice. While this technique includes the fashioning of an intra-corporeal anastomosis, it still requires an abdominal incision for specimen extraction. Elimination of the abdominal incision and its potential complications has been the motivation for the development of natural orifice specimen extraction (NOSE) techniques. Many of these techniques make use of an open rectal stump, which poses as a potential for intra-abdominal contamination. Our group has recently described a novel, NOTES assisted, clean, endoluminal rectal resection utilizing transabdominal and transanal approaches. In this paper we report the combined experience of two study groups: an open approach to the abdominal cavity and a laparoscopic approach to the peritoneal cavity. Ten female pigs were used for this research; 5 in a group using an open approach and 5 using a laparoscopic approach for the abdominal part of the procedure. During the procedure, the rectum was mobilized. An end-to-end circular stapler was used to create a recto-rectal intussusception and pull-through (IPT). The specimen was resected and extracted by making a full thickness incision through 2 bowel walls. The stapler was applied, and a recto-rectal anastomosis created. This was allowed to retract into the abdomen. Peritoneal fluid was sampled for bacteria, the pigs were sacrificed immediately after the experiment and necropsy was performed. All 10 pigs underwent an endoluminal rectal resection utilizing the trans-anal IPT technique. The proximal and distal resection margins remained approximated over the shaft of the anvil after bowel resection in all 10 subjects. A 2- to 4-mm resection margin, distal to the ligatures was accomplished consistently in all 10 subjects. No aerobic or anaerobic bacterial growth was observed in any of the peritoneal fluid samples. Our research demonstrated

  15. Bed conduction impact on fiber optic distributed temperature sensing water temperature measurements

    NASA Astrophysics Data System (ADS)

    O'Donnell Meininger, T.; Selker, J. S.

    2015-02-01

    Error in distributed temperature sensing (DTS) water temperature measurements may be introduced by contact of the fiber optic cable sensor with bed materials (e.g., seafloor, lakebed, streambed). Heat conduction from the bed materials can affect cable temperature and the resulting DTS measurements. In the Middle Fork John Day River, apparent water temperature measurements were influenced by cable sensor contact with aquatic vegetation and fine sediment bed materials. Affected cable segments measured a diurnal temperature range reduced by 10% and lagged by 20-40 min relative to that of ambient stream temperature. The diurnal temperature range deeper within the vegetation-sediment bed material was reduced 70% and lagged 240 min relative to ambient stream temperature. These site-specific results illustrate the potential magnitude of bed-conduction impacts with buried DTS measurements. Researchers who deploy DTS for water temperature monitoring should understand the importance of the environment into which the cable is placed on the range and phase of temperature measurements.

  16. SU-F-J-122: Rectal Sparing Reproducibility in Prostate Cancer Patients Treated with Hydrogel Spacer and Proton Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hedrick, S; Robison, B; Blakey, M

    2016-06-15

    Purpose: Rectal hydrogel spacer has been shown to improve rectal sparing in prostate radiotherapy. The purpose of this study was to determine the reproducibility of rectal sparing throughout treatment in patients undergoing proton therapy. Methods: At our facility, prostate cancer patients are treated with pencil beam scanning proton therapy, utilizing an endorectal balloon (ERB) or rectal spacer hydrogel (Gel) “SpaceOAR” implant. All patients were treated with a full bladder and empty rectum (low residue diet and stool softeners). A quality assurance CT (QACT) was performed periodically throughout treatment to ensure rectal filling consistency and sparing in 41 patients treated withmore » Gel. The treatment planning (TP) dose was calculated on each QACT and the rectum V90%, V75%, V65%, V50%, and V40% were recorded. QACT scans were acquired on day 0, week 1, week 3, and week 5. Results: 144 QACT scans were analyzed, each patient receiving 3–4 QACTs. Rectum V90% was within +/−1% of the TP dose in 70% of the QACTs and within +/−5% in 95% of scans. From previous data analyses, our ERB rectum V90% average is 6%. This value was used as an upper threshold for the Gel QACT analysis. 5 of the 41 patients (12%), corresponding to 7 QACTs, had a rectum V90% that exceeded 6% on one or more QACTs. However, the average rectal V90% measured over multiple QACTs never exceeded 6%. 55% of the QACTs had a rectum volume within 5cc of the TPCT volume, 68% were within 10cc. Conclusion: In this study, we have shown that a majority of our prostate patients can maintain consistent rectal sparing when treated with a hydrogel spacer. QACT rectal V90% exceeding our threshold was most often related to increased rectal filling and gas, which was addressed with improved dietary compliance and the intensification of stool softeners or laxatives.« less

  17. Integrated Emissivity And Temperature Measurement

    DOEpatents

    Poulsen, Peter

    2005-11-08

    A multi-channel spectrometer and a light source are used to measure both the emitted and the reflected light from a surface which is at an elevated temperature relative to its environment. In a first method, the temperature of the surface and emissivity in each wavelength is calculated from a knowledge of the spectrum and the measurement of the incident and reflected light. In the second method, the reflected light is measured from a reference surface having a known reflectivity and the same geometry as the surface of interest and the emitted and the reflected light are measured for the surface of interest. These measurements permit the computation of the emissivity in each channel of the spectrometer and the temperature of the surface of interest.

  18. Effect of change in ambient temperature on core temperature during the daytime.

    PubMed

    Kakitsuba, Naoshi; White, Matthew D

    2014-07-01

    In this study, the hypothesis is tested that continuous increases in ambient temperature (Ta) during daytime would give elevated core and skin temperatures, and consequently better thermal sensation and comfort. Rectal temperature (Tre), skin temperatures and regional dry heat losses at 7 sites were continuously measured for 10 Japanese male subjects in three thermal conditions: cond. 1, stepwise increases in Ta from 26 °C at 9 h00 to 30 °C at 18 h00; cond. 2, steady Ta at 28 °C from 9 h00 to 18 h00 and cond. 3, stepwise decreases in Ta from 30 °C at 9 h00 to 26 °C at 18 h00. Oxygen consumption was measured and thermal sensation and comfort votes were monitored at 15 min intervals. Body weight loss was measured at 1 h intervals. While Tre increased continuously in the morning period in any condition, it increased to a significantly greater (p<0.05) 36.9±0.3 °C at 18 h00 in cond. 1 relative to 36.7±0.28 °C in Cond. 2 and 36.5±0.37 °C in cond. 3. Better thermal comfort was observed in the afternoon and the evening in Cond.1 as compared with the other 2 conditions. Thus, a progressive and appropriate increase in Ta may induce optimal cycle in core temperature during daytime, particularly for a resting person.

  19. Human Collagen Injections to Reduce Rectal Dose During Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Noyes, William R., E-mail: noyes@cancercenternd.com; Hosford, Charles C.; Schultz, Steven E.

    Objectives: The continuing search for interventions, which address the incidence and grade of rectal toxicities associated with radiation treatment of prostate cancer, is a major concern. We are reporting an investigational trial using human collagen to increase the distance between the prostate and anterior rectal wall, thereby decreasing the radiation dose to the rectum. Methods: This is a pilot study evaluating the use of human collagen as a displacing agent for the rectal wall injected before starting a course of intensity-modulated radiotherapy (IMRT) for prostate cancer. Using a transperineal approach, 20 mL of human collagen was injected into the perirectalmore » space in an outpatient setting. Computerized IMRT plans were performed pre- and postcollagen injection, and after a patient completed their radiotherapy, to determine radiation dose reduction to the rectum associated with the collagen injection. Computed tomography scans were performed 6 months and 12 months after completing their radiotherapy to evaluate absorption rate of the collagen. All patients were treated with IMRT to a dose of 75.6 Gy to the prostate. Results: Eleven patients were enrolled into the study. The injection of human collagen in the outpatient setting was well tolerated. The mean separation between the prostate and anterior rectum was 12.7 mm. The mean reduction in dose to the anterior rectal wall was 50%. All men denied any rectal symptoms during the study. Conclusions: The transperineal injection of human collagen for the purpose of tissue displacement is well tolerated in the outpatient setting. The increased separation between the prostate and rectum resulted in a significant decrease in radiation dose to the rectum while receiving IMRT and was associated with no rectal toxicities.« less

  20. SU-E-T-257: Development of a New Endorectal Balloon with An Unfoldable Radiochromic Film for In-Vivo Rectal Dosimetry During Prostate Cancer Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jeang, E; Lim, Y; Cho, K

    Purpose: We developed an endorectal balloon for in-vivo rectal dosimetry in two-dimensions, and evaluated its dosimetric properties for the radiation treatment of prostate cancer. Methods: The endorectal balloon for in-vivo rectal dosimetry is equipped with a radiochromic film so that two-dimensional dose distribution can be measured in the rectal wall. The film is unrolled as the balloon is inflated, and it is rolled as the balloon is deflated. The outer diameter of the balloon is about 14 mm before inflating it, but its outer diameter can be increased up to about 50 mm after inflating it with 80 ml distilledmore » water. The size of the film is 80(L) x 64(W) mm2, so large as to measure a dose distribution of an anterior half of the rectal wall. After it was inserted into a fabricated rectal phantom, the phantom was scanned by a CT scanner and 5 Gy was delivered to a target inside the phantom with a 15 MV photon beam in AP direction. Finally, the dose distribution measured in the endorectal balloon was compared with that of the treatment plan. Results: The two dose distributions were compared each other in the parallel and the perpendicular directions along an axis of the balloon. The two dose profiles analyzed from the radiochromic film agreed well with the plan within 3% for 15 MV photon beam. Conclusion: An endorectal balloon for two-dimensional in-vivo rectal dosimetry was developed and its dosimetric effectiveness was evaluated for the radiation treatment of prostate cancer. The measured dose distributions showed good agreement with the plans.« less

  1. Effect of ambient temperature on the thermal profile of the human forearm, hand, and fingers

    NASA Technical Reports Server (NTRS)

    Montgomery, L. D.; Williams, B. A.

    1976-01-01

    Forearm, hand, and finger skin temperatures were measured on the right and left sides of seven resting men. The purpose was to determine the bilateral symmetry of these segmental temperature profiles at ambient temperatures from 10 to 45 C. Thermistors placed on the right and left forearms, hands, and index fingers were used to monitor the subjects until equilibration was reached at each ambient temperature. Additionally, thermal profiles of both hands were measured with copper-constantan thermocouples. During one experimental condition (23 C ambient), rectal, ear canal, and 24 skin temperatures were measured on each subject. Average body and average skin temperatures are given for each subject at the 23 C ambient condition. Detailed thermal profiles are also presented for the dorsal, ventral, and circumferential left forearm, hand, and finger skin temperatures at 23 C ambient. No significant differences were found between the mean skin temperatures of the right and left contralateral segments at any of the selected ambient temperatures.

  2. 8-13 Hz fluctuations in rectal pressure are an objective marker of clitorally-induced orgasm in women.

    PubMed

    van Netten, Jaap J; Georgiadis, Janniko R; Nieuwenburg, Arie; Kortekaas, Rudie

    2008-04-01

    Orgasm is a subjective experience accompanied by involuntary muscle contractions. We hypothesized that orgasm in women would be distinguishable by frequency analysis of a perineal muscle-derived signal. Rectal pressure, an index of perineal muscle activity, was measured continuously in 23 healthy women during different sexual tasks: receiving clitoral stimulation, imitation of orgasm, and attempt to reach orgasm, in which case the women were asked to report whether orgasm had been reached ("orgasm") or not ("failed orgasm attempt"). We performed spectral analysis on the rectal pressure data and calculated the spectral power in the frequency bands delta (0.5-4 Hz), theta (4-8 Hz), alpha (8-13 Hz), and beta (13-25 Hz). The most significant and most important difference in spectral power between orgasm and both control motor tasks (imitation of orgasm and failed orgasm attempt) was found in the alpha band. An objective rule based on spectral power in the alpha band recognized 94% (29/31) of orgasms and correctly labeled 69% (44/64) of all orgasm attempts as either successful or failed. Because outbursts of alpha fluctuations in rectal pressure only occurred during orgasm and not during voluntary imitation of orgasm or failed attempts, we propose that they represent involuntary contractions of muscles in the rectal vicinity. This is the first objective and quantitative measure that has a strong correspondence with the subjective experience of orgasm.

  3. Temperature measuring device

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lauf, R.J.; Bible, D.W.; Sohns, C.W.

    1999-10-19

    Systems and methods are described for a wireless instrumented silicon wafer that can measure temperatures at various points and transmit those temperature readings to an external receiver. The device has particular utility in the processing of semiconductor wafers, where it can be used to map thermal uniformity on hot plates, cold plates, spin bowl chucks, etc. without the inconvenience of wires or the inevitable thermal perturbations attendant with them.

  4. Temperature measuring device

    DOEpatents

    Lauf, Robert J.; Bible, Don W.; Sohns, Carl W.

    1999-01-01

    Systems and methods are described for a wireless instrumented silicon wafer that can measure temperatures at various points and transmit those temperature readings to an external receiver. The device has particular utility in the processing of semiconductor wafers, where it can be used to map thermal uniformity on hot plates, cold plates, spin bowl chucks, etc. without the inconvenience of wires or the inevitable thermal perturbations attendant with them.

  5. Unobtrusive Monitoring of Neonatal Brain Temperature Using a Zero-Heat-Flux Sensor Matrix.

    PubMed

    Atallah, Louis; Bongers, Edwin; Lamichhane, Bishal; Bambang-Oetomo, Sidarto

    2016-01-01

    The temperature of preterm neonates must be maintained within a narrow window to ensure their survival. Continuously measuring their core temperature provides an optimal means of monitoring their thermoregulation and their response to environmental changes. However, existing methods of measuring core temperature can be very obtrusive, such as rectal probes, or inaccurate/lagging, such as skin temperature sensors and spot-checks using tympanic temperature sensors. This study investigates an unobtrusive method of measuring brain temperature continuously using an embedded zero-heat-flux (ZHF) sensor matrix placed under the head of the neonate. The measured temperature profile is used to segment areas of motion and incorrect positioning, where the neonate's head is not above the sensors. We compare our measurements during low motion/stable periods to esophageal temperatures for 12 preterm neonates, measured for an average of 5 h per neonate. The method we propose shows good correlation with the reference temperature for most of the neonates. The unobtrusive embedding of the matrix in the neonate's environment poses no harm or disturbance to the care work-flow, while measuring core temperature. To address the effect of motion on the ZHF measurements in the current embodiment, we recommend a more ergonomic embedding ensuring the sensors are continuously placed under the neonate's head.

  6. Female users of internet-based screening for rectal STIs: descriptive statistics and correlates of positivity.

    PubMed

    Ladd, Jessica; Hsieh, Yu-Hsiang; Barnes, Mathilda; Quinn, Nicole; Jett-Goheen, Mary; Gaydos, Charlotte A

    2014-09-01

    Internet-based screening for vaginal sexually transmitted infections (STI) has been shown to reach high-risk populations. Published studies of internet-based screening for rectal STIs in women are needed. Our objectives were to describe the female users of a rectal internet-based screening intervention and assess what factors correlated with rectal positivity for STIs. The website http://www.iwantthekit.org offers free STI testing via home self-sampling kits. Women could order vaginal and rectal kits, both containing questionnaires. Rectal and vaginal swabs were tested for Chlamydia trachomatis, Neisseria gonorrhoeae and Trichomonas vaginalis using nucleic acid amplification tests. Data were analysed from 205 rectal kits from January 2009 through February 2011. Self-reported characteristics of participants were examined, and correlates of rectal STI positivity were analysed. Of the 205 rectal samples returned and eligible for testing, 38 (18.5%) were positive for at least one STI. The women were young (mean age 25.8 years), mostly African-American (50.0%), and only 14.0% always used condoms. After adjusting for age and race, Black race (AOR=3.06) and vaginal STI positivity (AOR=40.6) were significantly correlated with rectal STI positivity. Of women testing positive for rectal STIs who also submitted vaginal swabs, 29.4% were negative in the vaginal sample. Internet-based rectal screening can reach populations that appear to be at high risk for rectal STIs (18.5% prevalence) and led to the diagnosis of STIs in women who would not have been diagnosed vaginally. Black race and vaginal STI positivity were highly correlated with rectal STI positivity. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  7. Value of diffusion-weighted MRI and apparent diffusion coefficient measurements for predicting the response of locally advanced rectal cancer to neoadjuvant chemoradiotherapy.

    PubMed

    Iannicelli, Elsa; Di Pietropaolo, Marco; Pilozzi, Emanuela; Osti, Mattia Falchetto; Valentino, Maria; Masoni, Luigi; Ferri, Mario

    2016-10-01

    The aim of our study was to assess the performance value of magnetic resonance imaging (MRI) in the restaging of locally advanced rectal cancer after neoadjuvant chemoradiotherapy (CRT) and in the identification of good vs. poor responders to neoadjuvant therapy. A total of 34 patients with locally advanced rectal cancer underwent MRI prior to and after CRT. T stage and tumor regression grade (TRG) on post-CRT MRI was compared with the pathological staging ypT and TRG. Tumor volume and the apparent diffusion coefficient (ADC) were measured using diffusion-weighted imaging (DWI) before and after neoadjuvant CRT; the percentage of tumor volume reduction and the change of ADC (ΔADC) was also calculated. ADC parameters and the percentage of tumor volume reduction were correlated to histopathological results. The diagnostic performance of ADC and volume reduction to assess tumor response was evaluated by calculating the area under the ROC curve and the optimal cut-off values. A significant correlation between the T stage and the TRG defined in DW-MRI after CRT and the ypT and the TRG observed on the surgical specimens was found (p = 0.001; p < 0.001). The mean post-CRT ADC and ΔADC in responder patients was significantly higher compared to non-responder ones (p = 0.001; p = 0.01). Furthermore, the mean post-CRT ADC values were significantly higher in tumors with T-downstage (p = 0.01). DW-MRI may have a significant role in the restaging and in the evaluation of post-CRT response of locally advanced rectal cancer. Quantitative analysis of DWI through ADC map may result in a promising noninvasive tool to evaluate the response to therapy.

  8. [Rectal carcinoma in a 24-year-old man with Hirschsprung's disease].

    PubMed

    Henriksen, Jeppe; Green, Charlotte; Ljungmann, Ken

    2018-06-18

    This case report presents an incident of rectal carcinoma in a 24-year-old man with Hirschsprung's disease, for which he was operated in his early childhood, with a Soave pull-through procedure. No direct association between Hirschsprung's disease and rectal cancer was found in our review of the literature. However, several case reports of rectal cancers following pull-through procedures exist. A low threshold for further clinical investigations is recommended, if these patients are presenting with gastrointestinal symptoms.

  9. [Rectal mucosal prolapse syndrome: study of cases. Hospital Daniel A Carrion, Lima, Peru, 2010-2013].

    PubMed

    Arévalo Suarez, Fernando; Cárdenas Vela, Irene; Rodríguez Rodríguez, Kriss; Pérez Narrea, María Teresa; Rodríguez Vargas, Omar; Montes Teves, Pedro; Monge Salgado, Eduardo

    2014-04-01

    to describe the clinical, endoscopic, and histological characteristics of rectal mucosal prolapse syndrome, formerly known as Solitary rectal ulcer, in patients from a general hospital. All patient diagnosed as rectal mucosal prolapse syndrome during 2010-2013 was selected; the medical history war reviewed and the histological slides were reevaluated by two pathologists. 17 cases of rectal mucosal prolapse syndrome were selected, the majority were males under 50 years, the most common clinical findings were rectal bleeding (82%) and constipation (65%), the endocopic findings were heterogeneous,: erythema (41%), ulcers (35%) and elevated lesions (29%). All cases presented fibromuscularhyperplasia in lamina propia and crypt distortion in the microscopic evaluation. In our study of rectal mucosal prolapse syndrome. The most common clinical findings were rectal bleeding and constipation. Erythematous mucosa was the most common endoscopic finding.

  10. Reduction of prostate intrafraction motion using gas-release rectal balloons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Su Zhong; Zhao Tianyu; Li Zuofeng

    2012-10-15

    Purpose: To analyze prostate intrafraction motion using both non-gas-release (NGR) and gas-release (GR) rectal balloons and to evaluate the ability of GR rectal balloons to reduce prostate intrafraction motion. Methods: Twenty-nine patients with NGR rectal balloons and 29 patients with GR balloons were randomly selected from prostate patients treated with proton therapy at University of Florida Proton Therapy Institute (Jacksonville, FL). Their pretreatment and post-treatment orthogonal radiographs were analyzed, and both pretreatment setup residual error and intrafraction-motion data were obtained. Population histograms of intrafraction motion were plotted for both types of balloons. Population planning target-volume (PTV) margins were calculated withmore » the van Herk formula of 2.5{Sigma}+ 0.7{sigma} to account for setup residual errors and intrafraction motion errors. Results: Pretreatment and post-treatment radiographs indicated that the use of gas-release rectal balloons reduced prostate intrafraction motion along superior-inferior (SI) and anterior-posterior (AP) directions. Similar patient setup residual errors were exhibited for both types of balloons. Gas-release rectal balloons resulted in PTV margin reductions from 3.9 to 2.8 mm in the SI direction, 3.1 to 1.8 mm in the AP direction, and an increase from 1.9 to 2.1 mm in the left-right direction. Conclusions: Prostate intrafraction motion is an important uncertainty source in radiotherapy after image-guided patient setup with online corrections. Compared to non-gas-release rectal balloons, gas-release balloons can reduce prostate intrafraction motion in the SI and AP directions caused by gas buildup.« less

  11. Rectal prolapse repair - series (image)

    MedlinePlus

    ... the body through the anus. The rectum is anchored in position by ligaments. When these ligaments weaken, the rectum can move out of its normal position, downward, and pass through the anus. This is called rectal prolapse.

  12. Rectal 5-aminosalicylic acid for induction of remission in ulcerative colitis.

    PubMed

    Marshall, John K; Thabane, Marroon; Steinhart, A Hillary; Newman, Jamie R; Anand, Anju; Irvine, E Jan

    2010-01-20

    .00001), histologic improvement 7.69 (6 trials, 95% CI 3.26 to 18.12; P < 0.00001), symptomatic remission 8.30 (8 trials, 95% CI 4.28 to 16.12; P < 0.00001), endoscopic remission 5.31 (7 trials, 95% CI 3.15 to 8.92; P < 0.00001), and histologic remission 6.28 (5 trials, 95% CI 2.74 to 14.40; P < 0.0001). Rectal 5-ASA was superior to rectal corticosteroids for inducing symptomatic improvement and remission with POR 1.56 (6 trials, 95% CI 1.15 to 2.11; P = 0.004) and 1.65 (6 trials, 95% CI 1.11 to 2.45; P = 0.01), respectively. Rectal 5-ASA was not superior to oral 5-ASA for symptomatic improvement (POR 2.25; 95% CI 0.53 to 19.54; P = 0.27). Neither total daily dose nor 5-ASA formulation affected treatment response. Rectal 5-ASA should be considered a first-line therapy for patients with mild to moderately active distal UC. The optimal total daily dose and dose frequency of 5-ASA remain to be determined. Future research should define differences in efficacy among patient subgroups defined by proximal disease margin and disease activity. There is a strong need for consensus standardization of outcome measurements for clinical trials in ulcerative colitis.

  13. Risk factors and outcomes of organ-space surgical site infections after elective colon and rectal surgery.

    PubMed

    Gomila, Aina; Carratalà, Jordi; Camprubí, Daniel; Shaw, Evelyn; Badia, Josep Mª; Cruz, Antoni; Aguilar, Francesc; Nicolás, Carmen; Marrón, Anna; Mora, Laura; Perez, Rafel; Martin, Lydia; Vázquez, Rosa; Lopez, Ana Felisa; Limón, Enric; Gudiol, Francesc; Pujol, Miquel

    2017-01-01

    differences could be considered for surveillance purposes and for the implementation of preventive strategies. Administration of OAP would be an important measure to reduce the OS-SSI rate in both colon and rectal surgeries.

  14. Evidence that enforced sunlight exposure can cause hyperthermia in cattle ingesting low levels of ergot of rye (Claviceps purpurea), when air temperature and humidity conditions are only moderate.

    PubMed

    Bourke, C A

    2003-09-01

    To determine the rectal temperature response of cattle, following the oral administration of ergot of rye (Claviceps purpurea), under pen conditions of enforced sunlight compared with those of enforced shade. Hereford cross steers were divided into two groups of 18. One group was dosed once, on a Monday morning, with finely ground rye grass ergots at a rate of 180 mg/kg body weight and held in the sun for 7 h each day until Friday afternoon. The other group was not dosed but was similarly held in the sun during the same period. Their rectal temperatures were measured early morning and mid afternoon, from Monday to Friday inclusive. The process was repeated for each group, but this time they were held in the shade. The four treatment options were run concurrently by conducting the experiments over 6 weeks and using 3 animals in each treatment group, each week. The thermic response over all weeks, of the ergot treated, sunlight exposed cattle, was deemed greater than for the other groups, based on the following four parameters. The increase in rectal temperature between early morning and mid afternoon, the size of the mid afternoon rectal temperature rise, the difference between the maximum mid afternoon rectal temperature recorded by an animal in the sun compared with that recorded by the same animal in the shade, and finally the number of animals in a treatment group that recorded rectal temperatures > 40.00 degrees C. The difference in the daily increase in body temperature between the ergot treated, sun exposed cattle and the ergot treated, shaded cattle, was greater than that observed between the sun exposed and shade restricted control cattle. Nine of 18 ergot treated and sun exposed cattle developed hyperthermia; no cattle in the other three groups did. Some sunlight exposed cattle, dosed with a low amount of ergot of rye, can experience a body temperature elevation above the normal range, even under mild ambient temperature and humidity conditions. Sunlight

  15. Anorectal function in patients with complete rectal prolapse. Differences between continent and incontinent individuals.

    PubMed

    Roig, J V; Buch, E; Alós, R; Solana, A; Fernández, C; Villoslada, C; García-Armengol, J; Hinojosa, J

    1998-11-01

    A study is made of the alterations in anorectal physiology among rectal prolapse patients, evaluating the differences between fecal continent and incontinent individuals. Eighteen patients with complete rectal prolapse were divided into two groups: Group A (8 continent individuals) and Group B (10 incontinent women), while 22 healthy women were used as controls (Group C). Clinical exploration and perineal level measurements were performed, along with anorectal manometry, electrophysiology, and anorectal sensitivity to electrical stimuli. The main antecedents of the continent subjects were excess straining efforts, while the incontinent women presented excess straining and complex deliveries. Pathological perineal descent was a frequent finding in both groups, with a hypotonic anal canal at rest (p < 0.001 vs controls) and at voluntary squeezing (p < 0.001 vs controls). In turn, the incontinent patients exhibited a significantly lower anal canal pressure at rest than the continent women (p < 0.05). There were no significant differences between Groups A and C in terms of pudendal motor latency, though latency was significantly longer in Group B than in the controls (p < 0.01). Moreover, pudendal neuropathy was more common, severe and often bilateral in Group B. There were no differences in rectal sensation to distention or in terms of the volumes required to relax the internal anal sphincter. In turn, both prolapse groups exhibited diminished anal canal and rectal sensitivity to electrical stimuli. Patients with rectal prolapse exhibit a hypotonic anal canal at rest, regardless of whether they are continent to feces or not. Continent patients have less pudendal neuropathy and therefore less pressure alterations at voluntary sphincter squeeze than incontinent individuals.

  16. Body temperature and its effect on leukocyte mobilization, cytokines and markers of neutrophil activation during and after exercise.

    PubMed

    Peake, Jonathan; Peiffer, Jeremiah J; Abbiss, Chris R; Nosaka, Kazunori; Okutsu, Mitsuharu; Laursen, Paul B; Suzuki, Katsuhiko

    2008-03-01

    We investigated the influence of rectal temperature on the immune system during and after exercise. Ten well-trained male cyclists completed exercise trials (90 min cycling at 60% VO(2max) + 16.1 - km time trial) on three separate occasions: once in 18 degrees C and twice in 32 degrees C. Twenty minutes after the trials in 32 degrees C, the cyclists sat for approximately 20 min in cold water (14 degrees C) on one occasion, whereas on another occasion they sat at room temperature. Rectal temperature increased significantly during cycling in both conditions, and was significantly higher after cycling in 32 degrees C than in 18 degrees C (P < 0.05). Leukocyte counts increased significantly during cycling but did not differ between the conditions. The concentrations of serum interleukin (IL)-6, IL-8 and IL-10, plasma catecholamines, granulocyte-colony stimulating factor, myeloperoxidase and calprotectin increased significantly following cycling in both conditions. The concentrations of serum IL-8 (25%), IL-10 (120%), IL-1 receptor antagonist (70%), tumour necrosis factor-alpha (17%), plasma myeloperoxidase (26%) and norepinephrine (130%) were significantly higher after cycling in 32 degrees C than in 18 degrees C. During recovery from exercise in 32 degrees C, rectal temperature was significantly lower in response to sitting in cold water than at room temperature. However, immune changes during 90 min of recovery did not differ significantly between sitting in cold water and at room temperature. The greater rise in rectal temperature during exercise in 32 degrees C increased the concentrations of serum IL-8, IL-10, IL-1ra, TNF-alpha and plasma myeloperoxidase, whereas the greater decline in rectal temperature during cold water immersion after exercise did not affect immune responses.

  17. Accuracy of different temperature reading techniques and associated stress response in hospitalized dogs.

    PubMed

    Gomart, Samantha B; Allerton, Fergus J W; Gommeren, Kris

    2014-01-01

    To evaluate the accuracy and associated induced stress response of axillary, auricular, and rectal thermometry in hospitalized dogs. Prospective observational study from October 2011 to February 2012. University veterinary teaching hospital. Two hundred fifty hospitalized dogs. All hospitalized dogs were considered eligible unless their condition precluded measurement at one of the designated sites. A veterinary auricular infrared device for auricular temperature (OT) and an electronic predictive thermometer for rectal temperature (RT) and axillary temperature (AT) were used for temperature measurements. All recordings were obtained by the same investigator in a randomized fashion. Heart rate was noted before and immediately after each measurement. Stress behaviors (eg, vocalization, lip licking, shaking, panting, defensive behavior) were also recorded and graded from 0 (lowest) to 4 (highest). Signalment, analgesic therapy, and length of hospitalization were recorded. RT measurements were associated with greatest increase in heart rate (P < 0.05). Scores obtained for defensive behavior, lip licking, and vocalization were lowest with AT and highest with RT measurements (P < 0.05). Mean RT, AT, and OT were 38.0°C (SD: 0.85°C), 37.0°C (SD: 0.99°C), and 37.23°C (SD: 1.0382°C), respectively. AT and OT were moderately correlated with RT (r = 0.70 and r = 0.64, respectively). Gender (P = 0.02) and coat length (P = 0.03) had a significant influence on results. No effect of dehydration, body condition, analgesia, age, reproductive status, or operator experience was observed (P > 0.05). AT and to a lesser extent OT are reliable, less stressful alternatives to estimate RT in dogs. Further studies are needed to evaluate these techniques in hyperthermic dogs, and to evaluate the use of AT and OT as monitoring tools in intensive care patients. © Veterinary Emergency and Critical Care Society 2014.

  18. Systematic Review: Rectal Therapies for the Treatment of Distal Forms of Ulcerative Colitis.

    PubMed

    Cohen, Russell D; Dalal, Sushila R

    2015-07-01

    Many therapeutic options are available for patients with distal forms of ulcerative colitis (UC). Rectal therapies (e.g., suppositories, foams, gels, and enemas) may be recommended either alone or in combination with oral treatment. Compared with oral therapies, rectal therapies are underused in patients with distal forms of UC, although rectal therapies have favorable efficacy and safety profiles. This systematic review identified 48 articles for inclusion after a comprehensive PubMed search and the identification of additional relevant articles through other sources. Inclusion criteria were clinical studies examining efficacy and safety of 5-aminosalicylic acid, corticosteroid, and non-5-aminosalicylic acid rectal therapies (suppositories, foams, gels, and enemas) that induce or maintain remission in patients with ulcerative proctitis, ulcerative proctosigmoiditis, or left-sided colitis (i.e., distal forms of UC). The quality of the evidence presented was evaluated using the GRADE system. Overall, a greater percentage of patients with distal forms of UC receiving 5-aminosalicylic acids or corticosteroid rectal formulations derived greater therapeutic benefit after treatment compared with patients receiving placebo. Furthermore, most uncontrolled studies of rectal therapies reported that patients with distal forms of UC had marked improvement from baseline after treatment. The overall safety profile of rectal therapies was favorable. Treatment with second-generation corticosteroids, such as budesonide and beclomethasone dipropionate, did not increase the incidence of steroid-related adverse effects. The current literature supports the use of rectal therapies for both induction and maintenance of remission in patients with distal forms of UC.

  19. Rectal route in the 21st Century to treat children.

    PubMed

    Jannin, Vincent; Lemagnen, Gilles; Gueroult, Pascale; Larrouture, Denis; Tuleu, Catherine

    2014-06-01

    The rectal route can be considered a good alternative to the oral route for the paediatric population because these dosage forms are neither to be swallowed nor need to be taste-masked. Rectal forms can also be administered in an emergency to unconscious or vomiting children. Their manufacturing cost is low with excipients generally regarded as safe. Some new formulation strategies, including mucoadhesive gels and suppositories, were introduced to increase patient acceptability. Even if recent paediatric clinical studies have demonstrated the equivalence of the rectal route with others, in order to enable the use of this promising route for the treatment of children in the 21st Century, some effort should be focused on informing and educating parents and care givers. This review is the first ever to address all the aforementioned items, and to list all drugs used in paediatric rectal forms in literature and marketed products in developed countries. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Rectal adenocarcinoma infiltrating the bulbar urethra and metastasising to the penis

    PubMed Central

    James, Mathews; Amaranathan, Anandhi; Nelamangala Ramakrishnaiah, Vishnu Prasad; Toi, Pampa Chakrabarty

    2016-01-01

    Secondary penile tumours from rectal carcinoma is a known clinical entity but can be missed unless carefully evaluated. We report a case of rectal adenocarcinoma with synchronous painless penile nodules. A patient presented with constipation and rectal bleeding. He had an anorectal growth as well as palpable nodules on his penis. Rectal biopsy yielded adenocarcinoma. Imaging revealed direct infiltration of tumour into the bulb of the penis as well as distal shaft lesions. Fine-needle aspiration cytology of the penile nodule showed metastatic adenocarcinoma. Diversion colostomy was performed and the patient referred for chemoradiation. Since he did not have any urinary symptoms, the penile lesions were left unaltered. Repeat imaging after concurrent chemoradiotherapy showed no response. The prognosis was explained and the patient was given palliative clinic care. PMID:27312852

  1. Thermal responses from repeated exposures to severe cold with intermittent warmer temperatures.

    PubMed

    Ozaki, H; Enomoto-Koshimizu, H; Tochihara, Y; Nakamura, K

    1998-09-01

    This study was conducted to evaluate physiological reaction and manual performance during exposure to warm (30 degrees C) and cool (10 degrees C) environments after exposure to very low temperatures (-25 degrees C). Furthermore, this experiment was conducted to study whether it is desirable to remove cold-protective jackets in warmer rooms after severe cold exposure. Eight male students remained in an extremely cold room for 20 min, after which they transferred into either the warm room or the cool room for 20 min. This pattern was repeated three times, and the total cold exposure time was 60 min. In the warm and cool rooms, the subjects either removed their cold-protective jackets (Condition A), or wore them continuously (Condition B). Rectal temperature, skin temperatures, manual performance, blood pressure, thermal, comfort and pain sensations were measured during the experiment. The effects of severe cold on almost all measurements in the cool (10 degrees C) environment were greater than those in the warm (30 degrees C) environment under both clothing conditions. The effects of severe cold on all measurements under Condition A except rectal temperature and toe skin temperature were significantly greater than those under Condition B in the cool environment but, not at all differences between Condition A and Condition B in the warm environments were significant. It was recognized that to remove cold-protective jackets in the cool room (10 degrees C) after severe cold exposure promoted the effects of severe cold. When rewarming in the warm resting room (30 degrees C), the physiological and psychological responses and manual performance were not influenced by the presence or absence of cold-protective clothing. These results suggest that it is necessary for workers to make sure to rewarm in the warm room outside of the cold storage and continue to wear cold-protective clothing in the cool room.

  2. Low-dose rectal diclofenac for prevention of post-endoscopic retrograde cholangiopancreatography pancreatitis: a randomized controlled trial.

    PubMed

    Otsuka, Taiga; Kawazoe, Seiji; Nakashita, Shunya; Kamachi, Saori; Oeda, Satoshi; Sumida, Chinatsu; Akiyama, Takumi; Ario, Keisuke; Fujimoto, Masaru; Tabuchi, Masanobu; Noda, Takahiro

    2012-08-01

    Acute pancreatitis is a common complication of endoscopic retrograde cholangiopancreatography (ERCP). Rectal nonsteroidal anti-inflammatory drugs (specifically, 100 mg of diclofenac or indomethacin) have shown promising prophylactic activity in post-ERCP pancreatitis (PEP). However, the 100-mg dose is higher than that ordinarily used in Japan. We performed a prospective randomized controlled study to evaluate the efficacy of low-dose rectal diclofenac for the prevention of PEP. Patients who were scheduled to undergo ERCP were randomized to receive a saline infusion either with 50 mg of rectal diclofenac (diclofenac group) or without (control group) 30 min before ERCP. The dose of diclofenac was reduced to 25 mg in patients weighing <50 kg. The primary outcome measure was the occurrence of PEP. Enrollment was terminated early because the planned interim analysis found a statistically significant intergroup difference in the occurrence of PEP. A total of 104 patients were eligible for this study; 51 patients received rectal diclofenac. Twelve patients (11.5%) developed PEP: 3.9% (2/51) in the diclofenac group and 18.9% (10/53) in the control group (p = 0.017). After ERCP, the incidence of hyperamylasemia was not significantly different between the two groups. Post-ERCP pain was significantly more frequent in the control group than in the diclofenac group (37.7 vs. 7.8%, respectively; p < 0.001). There were no adverse events related to diclofenac. Low-dose rectal diclofenac can prevent PEP.

  3. High Prevalence of Rectal Gonorrhea and Chlamydia Infection in Women Attending a Sexually Transmitted Disease Clinic

    PubMed Central

    Reese, Patricia Carr; Esber, Allahna; Lahey, Samantha; Ervin, Melissa; Davis, John A.; Fields, Karen; Turner, Abigail Norris

    2015-01-01

    Abstract Background: Testing women for urogenital Neisseria gonorrhoeae (GC) and Chlamydia trachomatis (CT) is common in sexually transmitted disease (STD) clinics. However, women may not be routinely tested for rectal GC/CT. This may lead to missed infections in women reporting anal intercourse (AI). Methods: This was a retrospective review of all women who underwent rectal GC/CT testing from August 2012 to June 2013 at an STD clinic in Columbus, Ohio. All women who reported AI in the last year had a rectal swab collected for GC/CT nucleic acid amplification testing (n=331). Using log-binomial regression models, we computed unadjusted and adjusted associations for demographic and behavioral factors associated with rectal GC/CT infection. Results: Participants (n=331) were 47% African-American, with median age of 29 years. Prevalence of rectal GC was 6%, rectal CT was 13%, and either rectal infection was 19%. Prevalence of urogenital GC and CT was 7% and 13% respectively. Among women with rectal GC, 14% tested negative for urogenital GC. Similarly, 14% of women with rectal CT tested negative for urogenital CT. In unadjusted analyses, there was increased rectal GC prevalence among women reporting sex in the last year with an injection drug user, with a person exchanging sex for drugs or money, with anonymous partners, and while intoxicated/high on alcohol or illicit drugs. After multivariable adjustment, no significant associations persisted, but a trend of increased rectal GC prevalence was observed for women <26 years of age (p=0.06) and those reporting sex while intoxicated/high on alcohol or drugs (p=0.05). For rectal CT, only age <26 years was associated with prevalent infection in unadjusted models; this association strengthened after multivariable adjustment (prevalence ratio: 6.03; 95% confidence interval: 2.29–15.90). Conclusion: Nearly one in five women who reported AI in the last year had rectal GC or CT infection. Urogenital testing alone would have

  4. Combined effects of retinol, ascorbic acid and α-tocopherol on diurnal variations in rectal temperature of Black Harco pullets subjected to heat stress

    NASA Astrophysics Data System (ADS)

    Sinkalu, Victor Olusegun; Ayo, Joseph Olusegun

    2018-01-01

    The experiment was performed with the aim of determining the effect of co-administration of antioxidant vitamins, retinol, ascorbic acid and α-tocopherol on rectal temperature (RT) fluctuations in pullets during the hot-dry season in Nigeria. Forty-eight Black Harco pullets, aged 16 weeks and weighing 1.5 ± 0.03 kg were divided by simple random sampling into two groups, consisting of 28 treated and 20 control Black Harco pullets. The RTs of 28 treated and 20 control Black Harco pullets were measured hourly for 3 days, 3 days apart, from 06:00 to 19:00 h (GMT + 1) with a standard clinical thermometer. The treated pullets were administered individually with the vitamins orally in water, while the control pullets were given only water. The lowest hourly RT of 40.9 ± 0.04 °C was obtained in treated pullets at 06:00 h, while the highest value of 41.1 ± 0.01 °C was recorded from 17:00 to 19:00 h ( P < 0.001). In control pullets, the RT rose significantly from 41.0 ± 0.03 °C at 06:00 h to the maximum value of 41.6 ± 0.04 °C at 15:00 h ( P < 0.001). The pullets co-administered with retinol, ascorbic acid and α-tocopherol had consistently lower RT values than those of control pullets, especially during the hot hours of the day, from 13:00 to 17:00 h. It is concluded that co-administration of retinol, ascorbic acid and α-tocopherol, by preventing a rise in body temperature, ameliorated heat stress, and may enhance productivity of pullets reared under unfavourable, thermal environment conditions.

  5. Temperature measurement systems in wearable electronics

    NASA Astrophysics Data System (ADS)

    Walczak, S.; Gołebiowski, J.

    2014-08-01

    The aim of this paper is to present the concept of temperature measurement system, adapted to wearable electronics applications. Temperature is one of the most commonly monitored factor in smart textiles, especially in sportswear, medical and rescue products. Depending on the application, measured temperature could be used as an initial value of alert, heating, lifesaving or analysis system. The concept of the temperature measurement multi-point system, which consists of flexible screen-printed resistive sensors, placed on the T-shirt connected with the central unit and the power supply is elaborated in the paper.

  6. Rectal Microbicide Development

    PubMed Central

    McGowan, Ian

    2013-01-01

    Purpose of review Individuals practicing unprotected receptive anal intercourse are at particularly high risk of HIV infection. Men who have sex with men (MSM) in the developed and developing world continue to have disproportionate and increasing levels of HIV infection. The last few years have seen important progress in demonstrating the efficacy of oral pre-exposure prophylaxis (PrEP), vaginal microbicides, and treatment as prevention but there has also been significant progress in the development of rectal microbicides (RM). The purpose of this review is to summarize the status of RM research and to identify opportunities, challenges, and future directions in this important field of HIV prevention. Recent findings Recent Phase 1 RM studies have characterized the safety, acceptability, compartmental pharmacokinetics (PK), and pharmacodynamics (PD) of both UC781 and tenofovir gels. The tenofovir gel formulation used in vaginal studies was not well tolerated in the rectum and newer rectal specific formulations have been developed and evaluated in Phase 1 studies. Summary Complex Phase 1 studies have provided important data on candidate RMs. Tenofovir gel is poised to move into Phase 2 evaluation and it is possible that a Phase 2B/3 effectiveness study could be initiated in the next 2–3 years. PMID:23032732

  7. Differential effects of cathinone compounds and MDMA on body temperature in the rat, and pharmacological characterization of mephedrone-induced hypothermia

    PubMed Central

    Shortall, SE; Green, AR; Swift, KM; Fone, KCF; King, MV

    2013-01-01

    Background and Purpose Recreational users report that mephedrone has similar psychoactive effects to 3,4-methylenedioxymethamphetamine (MDMA). MDMA induces well-characterized changes in body temperature due to complex monoaminergic effects on central thermoregulation, peripheral blood flow and thermogenesis, but there are little preclinical data on the acute effects of mephedrone or other synthetic cathinones. Experimental Approach The acute effects of cathinone, methcathinone and mephedrone on rectal and tail temperature were examined in individually housed rats, with MDMA included for comparison. Rats were killed 2 h post-injection and brain regions were collected for quantification of 5-HT, dopamine and major metabolites. Further studies examined the impact of selected α-adrenoceptor and dopamine receptor antagonists on mephedrone-induced changes in rectal temperature and plasma catecholamines. Key Results At normal room temperature, MDMA caused sustained decreases in rectal and tail temperature. Mephedrone caused a transient decrease in rectal temperature, which was enhanced by α1-adrenoceptor and dopamine D1 receptor blockade, and a prolonged decrease in tail temperature. Cathinone and methcathinone caused sustained increases in rectal temperature. MDMA decreased 5-HT and/or 5-hydroxyindoleacetic acid (5-HIAA) content in several brain regions and reduced striatal homovanillic acid (HVA) levels, whereas cathinone and methcathinone increased striatal HVA and 5-HIAA. Cathinone elevated striatal and hypothalamic 5-HT. Mephedrone elevated plasma noradrenaline levels, an effect prevented by α-adrenoceptor and dopamine receptor antagonists. Conclusions and Implications MDMA and cathinones have different effects on thermoregulation, and their acute effects on brain monoamines also differ. These findings suggest that the adverse effects of cathinones in humans cannot be extrapolated from previous observations on MDMA. PMID:23043631

  8. Differential effects of cathinone compounds and MDMA on body temperature in the rat, and pharmacological characterization of mephedrone-induced hypothermia.

    PubMed

    Shortall, S E; Green, A R; Swift, K M; Fone, K C F; King, M V

    2013-02-01

    Recreational users report that mephedrone has similar psychoactive effects to 3,4-methylenedioxymethamphetamine (MDMA). MDMA induces well-characterized changes in body temperature due to complex monoaminergic effects on central thermoregulation, peripheral blood flow and thermogenesis, but there are little preclinical data on the acute effects of mephedrone or other synthetic cathinones. The acute effects of cathinone, methcathinone and mephedrone on rectal and tail temperature were examined in individually housed rats, with MDMA included for comparison. Rats were killed 2 h post-injection and brain regions were collected for quantification of 5-HT, dopamine and major metabolites. Further studies examined the impact of selected α-adrenoceptor and dopamine receptor antagonists on mephedrone-induced changes in rectal temperature and plasma catecholamines. At normal room temperature, MDMA caused sustained decreases in rectal and tail temperature. Mephedrone caused a transient decrease in rectal temperature, which was enhanced by α(1) -adrenoceptor and dopamine D(1) receptor blockade, and a prolonged decrease in tail temperature. Cathinone and methcathinone caused sustained increases in rectal temperature. MDMA decreased 5-HT and/or 5-hydroxyindoleacetic acid (5-HIAA) content in several brain regions and reduced striatal homovanillic acid (HVA) levels, whereas cathinone and methcathinone increased striatal HVA and 5-HIAA. Cathinone elevated striatal and hypothalamic 5-HT. Mephedrone elevated plasma noradrenaline levels, an effect prevented by α-adrenoceptor and dopamine receptor antagonists. MDMA and cathinones have different effects on thermoregulation, and their acute effects on brain monoamines also differ. These findings suggest that the adverse effects of cathinones in humans cannot be extrapolated from previous observations on MDMA. © 2012 The Authors. British Journal of Pharmacology © 2012 The British Pharmacological Society.

  9. Evaluation of manometric temperature measurement, a process analytical technology tool for freeze-drying: part I, product temperature measurement.

    PubMed

    Tang, Xiaolin; Nail, Steven L; Pikal, Michael J

    2006-02-10

    This study examines the factors that may cause systematic errors in the manometric temperature measurement (MTM) procedure used to evaluate product temperature during primary drying. MTM was conducted during primary drying using different vial loads, and the MTM product temperatures were compared with temperatures directly measured by thermocouples. To clarify the impact of freeze-drying load on MTM product temperature, simulation of the MTM vapor pressure rise was performed, and the results were compared with the experimental results. The effect of product temperature heterogeneity in MTM product temperature determination was investigated by comparing the MTM product temperatures with directly measured thermocouple product temperatures in systems differing in temperature heterogeneity. Both the simulated and experimental results showed that at least 50 vials (5 mL) were needed to give sufficiently rapid pressure rise during the MTM data collection period (25 seconds) in the freeze dryer, to allow accurate determination of the product temperature. The product temperature is location dependent, with higher temperature for vials on the edge of the array and lower temperature for the vials in the center of the array. The product temperature heterogeneity is also dependent upon the freeze-drying conditions. In product temperature heterogeneous systems, MTM measures a temperature close to the coldest product temperature, even if only a small fraction of the samples have the coldest product temperature. The MTM method is valid even at very low product temperature (-45 degrees C).

  10. Evaluation of manometric temperature measurement, a process analytical technology tool for freeze-drying: Part I, product temperature measurement.

    PubMed

    Tang, Xiaolin; Nail, Steven L; Pikal, Michael J

    2006-03-01

    This study examines the factors that may cause systematic errors in the manometric temperature measurement (MTM) procedure used to evaluate product temperature during primary drying. MTM was conducted during primary drying using different vial loads, and the MTM product temperatures were compared with temperatures directly measured by thermocouples. To clarify the impact of freeze-drying load on MTM product temperatures, simulation of the MTM vapor pressure rise was performed, and the results were compared with the experimental results. The effect of product temperature heterogeneity in MTM product temperature determination was investigated by comparing the MTM product temperatures with directly measured thermocouple product temperatures in systems differing in temperature heterogeneity. Both the simulated and experimental results showed that at least 50 vials (5 mL) were needed to give sufficiently rapid pressure rise during the MTM data collection period (25 seconds) in the freeze dryer, to allow accurate determination of the product temperature. The product temperature is location dependent, with higher temperature for vials on the edge of the array and lower temperature for the vials in the center of the array. The product temperature heterogeneity is also dependent upon the freeze-drying conditions. In product temperature heterogeneous systems, MTM measures a temperature close to the coldest product temperature, even, if only a small fraction of the samples have the coldest product temperature. The MTM method is valid even at very low product temperature (-45°C).

  11. Rectal cancer with synchronous liver metastases: Do we have a clear direction?

    PubMed

    Pathak, S; Nunes, Q M; Daniels, I R; Smart, N J; Poston, G J; Påhlman, L

    2015-12-01

    Rectal cancer is a common entity and often presents with synchronous liver metastases. There are discrepancies in management guidelines throughout the world regarding the treatment of advanced rectal cancer, which are further compounded when it presents with synchronous liver metastases. The following article examines the evidence regarding treatment options for patients with synchronous rectal liver metastases and suggests potential treatment algorithms. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Increased bioavailability of tacrolimus after rectal administration in rats.

    PubMed

    Sakai, Masayuki; Hobara, Norio; Hokama, Nobuo; Kameya, Hiromasa; Ohshiro, Susumu; Sakanashi, Matao; Saitoh, Hiroshi

    2004-09-01

    The oral bioavailability of tacrolimus is low and varies considerably in humans due to first-pass metabolism by cytochrome P450 (CYP) 3A4 and the active efflux mediated by P-glycoprotein. This study was undertaken to elucidate the usefulness of rectal administration of tacrolimus as an alternative route to improve its bioavailability. Tacrolimus powder was suspended in a suppository base (witepsol H-15) and the tacrolimus suppository was inserted into the anus of the rats. For comparison, tacrolimus was suspended in 0.5% sodium methylcellulose solution and administered orally to rats. The dose of tacrolimus was fixed to 2 mg/kg. Blood samples were collected periodically up to 24 h after dosing, and tacrolimus concentrations were assayed by microparticle enzyme immunoassay. The whole blood concentrations of tacrolimus after rectal administration were much greater than those after oral administration. The C(max) and AUC(0-24 h) values after rectal administration were 3.9- and 6.9-fold greater than those after oral administration, respectively. These results clearly suggest a possibility that rectal administration of tacrolimus is capable of improving its bioavailability and cutting the costs of tacrolimus treatment.

  13. Measuring Poisson Ratios at Low Temperatures

    NASA Technical Reports Server (NTRS)

    Boozon, R. S.; Shepic, J. A.

    1987-01-01

    Simple extensometer ring measures bulges of specimens in compression. New method of measuring Poisson's ratio used on brittle ceramic materials at cryogenic temperatures. Extensometer ring encircles cylindrical specimen. Four strain gauges connected in fully active Wheatstone bridge self-temperature-compensating. Used at temperatures as low as liquid helium.

  14. Hypothetical Rectal Microbicide Acceptability and Factors Influencing It among Men Who Have Sex with Men in Tianjin, China

    PubMed Central

    Zhang, Huifang; Yu, Hongxuyang; Zhao, Zheng; Yang, Jie; Zhang, Mianzhi; Zhang, Minying

    2016-01-01

    Objectives To measure potential acceptability of rectal microbicides and to explore factors likely to affect their acceptability among men who have sex with men (MSM). Methods Cross-sectional and retrospective surveys were conducted in this study. A questionnaire and a scale were used to measure the acceptability score for physical and functional characteristics of hypothetical rectal microbicides. We also evaluated the involvement of other factors such as sexual behaviors, social context, etc. Results MSMs we interviewed showed a high acceptability to rectal microbicides, indicated by the mean acceptability score of 2.92 (SD, 0.54, scale of 1–4). The results also suggested that microbicides were preferred in a cream form that can moisten and lubricate the rectum, prevent HIV infection and go unnoticed by their partners. Multivariate analysis showed that the microbicides acceptability varied significantly by education level (β = 0.135; P = 0.028), having casual partners (β = 0.174; P = 0.007), frequency of lubricant use (β = 0.134; P = 0.031), history of HIV test (β = 0.129; P = 0.036), willingness to use lubricant (β = 0.126; P = 0.045), locus of control by partners regarding STI infection (β = 0.168; P = 0.009). Conclusions A positive response to rectal microbicides among MSMs was found in our study, suggesting that rectal microbicides might have a potential market in MSMs and they might play an important role in HIV/STIs prevention as a supplement. Further studies may be considered to combine the acceptability study with clinical research together to understand the true feelings of MSMs when they use the products. PMID:27243457

  15. [Rectal cancer--review of methods and treatment results].

    PubMed

    Grotowski, Maciej

    2004-03-01

    Rectal cancer poses a significant worldwide problem. Until the late 19 century surgeons were convinced that surgical attempts of treating rectal cancers were doomed to failure. Currently, surgery is associated with a poor prognosis, a high likelihood of permanent colostomy and a high rate of local recurrence in patients with regional disease. Functional changes such as bladder dysfunction and impotence remain distressingly common consequences of conventional surgery. An important understanding of rectal cancer pathology allied to modern surgical techniques such as intestinal stapling guns has led to an increased number of sphincter saving operations. The technique of sharp dissection along definable planes known as total mesorectal excision (TME) produces the complete resection of an intact package of the rectum and surrounding mesorectum, enveloped within the visceral pelvic fascia with uninvolved circumferential margins. As a result of TME, 5-year survival figures have risen from 45-50% to 78%, local recurrence rates have declined from 30% to 5-8%, sphincter preservation has risen by at least 20%, and the rates of bladder dysfunction and impotence have declined from 50-70% to 15%. In some selected cases transanal techniques with or without radiotherapy have improved the success of local excision. The value of laparoscopic surgery for rectal cancer in terms of cancer outcome can only be assessed by large clinical trials with sufficient follow-up.

  16. Predictive factors and management of rectal bleeding side effects following prostate cancer brachytherapy.

    PubMed

    Price, Jeremy G; Stone, Nelson N; Stock, Richard G

    2013-08-01

    To report on the incidence, nature, and management of rectal toxicities following individual or combination brachytherapy following treatment for prostate cancer over a 17-year period. We also report the patient and treatment factors predisposing to acute ≥ grade 2 proctitis. A total of 2752 patients were treated for prostate cancer between October 1990 and April 2007 with either low-dose-rate brachytherapy alone or in combination with androgen depletion therapy (ADT) or external beam radiation therapy (EBRT) and were followed for a median of 5.86 years (minimum 1.0 years; maximum 19.19 years). We investigated the 10-year incidence, nature, and treatment of acute and chronic rectal toxicities following BT. Using univariate, and multivariate analyses, we determined the treatment and comorbidity factors predisposing to rectal toxicities. We also outline the most common and effective management for these toxicities. Actuarial risk of ≥ grade 2 rectal bleeding was 6.4%, though notably only 0.9% of all patients required medical intervention to manage this toxicity. The majority of rectal bleeding episodes (72%) occurred within the first 3 years following placement of BT seeds. Of the 27 patients requiring management for their rectal bleeding, 18 underwent formalin treatment and nine underwent cauterization. Post-hoc univariate statistical analysis revealed that coronary artery disease (CAD), biologically effective dose, rectal volume receiving 100% of the prescription dose (RV100), and treatment modality predict the likelihood of grade ≥2 rectal bleeding. Only CAD, treatment type, and RV100 fit a Cox regression multivariate model. Low-dose-rate prostate brachytherapy is very well tolerated and rectal bleeding toxicities are either self-resolving or effectively managed by medical intervention. Treatment planning incorporating adjuvant ADT while minimizing RV100 has yielded the best toxicity-free survival following BT. Copyright © 2013 Elsevier Inc. All rights

  17. Predictive Factors and Management of Rectal Bleeding Side Effects Following Prostate Cancer Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Price, Jeremy G.; Stone, Nelson N.; Stock, Richard G., E-mail: Richard.Stock@mountsinai.org

    2013-08-01

    Purpose: To report on the incidence, nature, and management of rectal toxicities following individual or combination brachytherapy following treatment for prostate cancer over a 17-year period. We also report the patient and treatment factors predisposing to acute ≥grade 2 proctitis. Methods and Materials: A total of 2752 patients were treated for prostate cancer between October 1990 and April 2007 with either low-dose-rate brachytherapy alone or in combination with androgen depletion therapy (ADT) or external beam radiation therapy (EBRT) and were followed for a median of 5.86 years (minimum 1.0 years; maximum 19.19 years). We investigated the 10-year incidence, nature, andmore » treatment of acute and chronic rectal toxicities following BT. Using univariate, and multivariate analyses, we determined the treatment and comorbidity factors predisposing to rectal toxicities. We also outline the most common and effective management for these toxicities. Results: Actuarial risk of ≥grade 2 rectal bleeding was 6.4%, though notably only 0.9% of all patients required medical intervention to manage this toxicity. The majority of rectal bleeding episodes (72%) occurred within the first 3 years following placement of BT seeds. Of the 27 patients requiring management for their rectal bleeding, 18 underwent formalin treatment and nine underwent cauterization. Post-hoc univariate statistical analysis revealed that coronary artery disease (CAD), biologically effective dose, rectal volume receiving 100% of the prescription dose (RV100), and treatment modality predict the likelihood of grade ≥2 rectal bleeding. Only CAD, treatment type, and RV100 fit a Cox regression multivariate model. Conclusions: Low-dose-rate prostate brachytherapy is very well tolerated and rectal bleeding toxicities are either self-resolving or effectively managed by medical intervention. Treatment planning incorporating adjuvant ADT while minimizing RV100 has yielded the best toxicity-free survival

  18. [Electrocoagulation on a fragment of anterior abdominal rectal muscle for the control of presacral bleeding during rectal resection].

    PubMed

    Casal Núñez, José Enrique; Martínez, María Teresa García; Poblador, Alejandro Ruano

    2012-03-01

    Presacral venous haemorrhage during rectal movement is low, but is often massive, and even fatal. Our objective is the "in vitro" determination of the results of electrocoagulation applied to a fragment of muscle on the sacral bone surface during rectal resection due to a malignant neoplasm of the rectum. Single-pole coagulation was applied "in vitro" with the selector at maximum power on a 2×2 cms muscle fragment, applied to the anterior side of the IV sacral vertebra until reaching boiling point. The method was used on 6 patients with bleeding of the presacral venous plexus. In the "in vitro" study, boiling point was reached in 90 seconds from applying the single-pole current on the muscle fragment. Electrocoagulation was applied to a 2×2 cm rectal muscle fragment in 6 patients with presacral venous haemorrhage, using pressure on the surface of the presacral bone, with the stopping of the bleeding being achieved in all cases. The use of indirect electrocoagulation on a fragment of the rectus abdominis muscle is a straightforward and highly effective technique for controlling presacral venous haemorrhage. Copyright © 2011 AEC. Published by Elsevier Espana. All rights reserved.

  19. The recommended Threshold Limit Values for heat exposure fail to maintain body core temperature within safe limits in older working adults.

    PubMed

    Lamarche, Dallon T; Meade, Robert D; D'Souza, Andrew W; Flouris, Andreas D; Hardcastle, Stephen G; Sigal, Ronald J; Boulay, Pierre; Kenny, Glen P

    2017-09-01

    The American Conference of Governmental and Industrial Hygienists (ACGIH®) Threshold Limit Values (TLV® guidelines) for work in the heat consist of work-rest (WR) allocations designed to ensure a stable core temperature that does not exceed 38°C. However, the TLV® guidelines have not been validated in older workers. This is an important shortcoming given that adults as young as 40 years demonstrate impairments in their ability to dissipate heat. We therefore evaluated body temperature responses in older adults during work performed in accordance to the TLV® recommended guidelines. On three occasions, 9 healthy older (58 ± 5 years) males performed a 120-min work-simulated protocol in accordance with the TLV® guidelines for moderate-to-heavy intensity work (360 W fixed rate of heat production) in different wet-bulb globe temperatures (WBGT). The first was 120 min of continuous (CON) cycling at 28.0°C WBGT (CON[28°C]). The other two protocols were 15-min intermittent work bouts performed with different WR cycles and WBGT: (i) WR of 3:1 at 29.0°C (WR3:1[29°C]) and (ii) WR of 1:1 at 30.0°C (WR1:1[30°C]). Rectal temperature was measured continuously. The rate of change in mean body temperature was determined via thermometry (weighting coefficients: rectal, 0.9; mean skin temperature, 0.1) and direct calorimetry. Rectal temperature exceeded 38°C in all participants in CON[28°C] and WR3:1[29°C] whereas a statistically similar proportion of workers exceeded 38°C in WR1:1[30°C] (χ 2 ; P = 0.32). The average time for rectal temperature to reach 38°C was: CON[28°C], 53 ± 7; WR3:1[29°C], 79 ± 11; and WR1:1[30°C], 100 ± 29 min. Finally, while a stable mean body temperature was not achieved in any work condition as measured by thermometry (i.e., >0°C·min -1 ; all P<0.01), heat balance as determined by direct calorimetry was achieved in WR3:1[29°C] and WR1:1[30°C] (both P ≥ 0.08). Our findings indicate that the TLV® guidelines do not prevent

  20. Low bioavailability of ergotamine tartrate after oral and rectal administration in migraine sufferers.

    PubMed Central

    Ibraheem, J J; Paalzow, L; Tfelt-Hansen, P

    1983-01-01

    Fifteen migraine patients were administered 2 mg ergotamine tartrate in a partial cross-over design as a single, oral tablet, rectal suppository and rectal solution. Eight of these patients were in a previous investigation given 0.5 mg ergotamine tartrate intravenously. The blood samples were taken up to 54 h after oral and suppository while it was followed for only 3 h after rectal solution. The chemical analysis was performed by applying h.p.l.c. method with a limit of sensitivity of 0.1 ng/ml ergotamine base in plasma. No ergotamine was detected in the blood samples after the oral route, whereas small and very variable quantities was found in blood after the rectal route. Regular calculation of bioavailability could therefore not be performed. An estimate of the maximal possible bioavailability was found to yield a mean value of 2% (tablets); 5% (suppositories) and 6% (rectal solution). Rectal solution elicited faster absorption and the extent of absorption was significantly higher (P less than 0.05) than for the suppository. PMID:6419759

  1. Rectal temperatures, respiratory rates, production, and reproduction performances of crossbred Girolando cows under heat stress in northeastern Brazil

    NASA Astrophysics Data System (ADS)

    da Costa, Antônio Nélson Lima; Feitosa, José Valmir; Montezuma, Péricles Afonso; de Souza, Priscila Teixeira; de Araújo, Airton Alencar

    2015-11-01

    This study compared the two breed groups of Girolando (½ Holstein ½ Gyr vs. ¾ Holstein ¼ Gyr) through analysis of the percentages (stressed or non-stressed cows) of rectal temperature (RT), respiratory rate (RR) and pregnancy rate (PR), and means of production and reproduction parameters to determine the group best suited to rearing in semiarid tropical climate. The experiment was conducted at the farm, in the municipality of Umirim, State of Ceará, Brazil. Two hundred and forty cows were used in a 2 × 2 factorial study; 120 of each group were kept under an intensive system during wet and dry seasons. The environmental parameters obtained were relative humidity (RH), air temperature (AT), and the temperature and humidity index (THI). Pregnancy diagnosis (PD) was determined by ultrasonography 30 days after artificial insemination (AI). The milk production of each cow was recorded with automated milkings in the farm. The variables were expressed as mean and standard error, evaluated by ANOVA at 5 % probability using the GLM procedure of SAS. Chi-square test at 5 % probability was applied to data of RT, RR, pregnancy rate (PR), and the number of AIs to obtain pregnancy. The majority of ½ Holstein cows showed mean values of RT and RR within the normal range in both periods and shifts. Most animals of the ¾ Holstein group exhibited the RR means above normal during the afternoon in the rainy and dry periods and RT means above normal during the afternoon in the dry period. After analyses, ½ Holstein crossbred cows are more capable of thermoregulating than ¾ Holstein cows under conditions of thermal stress, and the dry period was more impacting for bovine physiology with significant changes in physiological parameters, even for the first breed group. Knowledge of breed groups adapted to climatic conditions of northeastern Brazil can directly assist cattle farmers in selecting animals best adapted for forming herds.

  2. Rectal temperatures, respiratory rates, production, and reproduction performances of crossbred Girolando cows under heat stress in northeastern Brazil.

    PubMed

    da Costa, Antônio Nélson Lima; Feitosa, José Valmir; Montezuma, Péricles Afonso; de Souza, Priscila Teixeira; de Araújo, Airton Alencar

    2015-11-01

    This study compared the two breed groups of Girolando (½ Holstein ½ Gyr vs. ¾ Holstein ¼ Gyr) through analysis of the percentages (stressed or non-stressed cows) of rectal temperature (RT), respiratory rate (RR) and pregnancy rate (PR), and means of production and reproduction parameters to determine the group best suited to rearing in semiarid tropical climate. The experiment was conducted at the farm, in the municipality of Umirim, State of Ceará, Brazil. Two hundred and forty cows were used in a 2 × 2 factorial study; 120 of each group were kept under an intensive system during wet and dry seasons. The environmental parameters obtained were relative humidity (RH), air temperature (AT), and the temperature and humidity index (THI). Pregnancy diagnosis (PD) was determined by ultrasonography 30 days after artificial insemination (AI). The milk production of each cow was recorded with automated milkings in the farm. The variables were expressed as mean and standard error, evaluated by ANOVA at 5% probability using the GLM procedure of SAS. Chi-square test at 5% probability was applied to data of RT, RR, pregnancy rate (PR), and the number of AIs to obtain pregnancy. The majority of ½ Holstein cows showed mean values of RT and RR within the normal range in both periods and shifts. Most animals of the ¾ Holstein group exhibited the RR means above normal during the afternoon in the rainy and dry periods and RT means above normal during the afternoon in the dry period. After analyses, ½ Holstein crossbred cows are more capable of thermoregulating than ¾ Holstein cows under conditions of thermal stress, and the dry period was more impacting for bovine physiology with significant changes in physiological parameters, even for the first breed group. Knowledge of breed groups adapted to climatic conditions of northeastern Brazil can directly assist cattle farmers in selecting animals best adapted for forming herds.

  3. Learning curve in robotic rectal cancer surgery: current state of affairs.

    PubMed

    Jiménez-Rodríguez, Rosa M; Rubio-Dorado-Manzanares, Mercedes; Díaz-Pavón, José Manuel; Reyes-Díaz, M Luisa; Vazquez-Monchul, Jorge Manuel; Garcia-Cabrera, Ana M; Padillo, Javier; De la Portilla, Fernando

    2016-12-01

    Robotic-assisted rectal cancer surgery offers multiple advantages for surgeons, and it seems to yield the same clinical outcomes as regards the short-time follow-up of patients compared to conventional laparoscopy. This surgical approach emerges as a technique aiming at overcoming the limitations posed by rectal cancer and other surgical fields of difficult access, in order to obtain better outcomes and a shorter learning curve. A systematic review of the literature of robot-assisted rectal surgery was carried out according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. The search was conducted in October 2015 in PubMed, MEDLINE and the Cochrane Central Register of Controlled Trials, for articles published in the last 10 years and pertaining the learning curve of robotic surgery for colorectal cancer. It consisted of the following key words: "rectal cancer/learning curve/robotic-assisted laparoscopic surgery". A total of 34 references were identified, but only 9 full texts specifically addressed the analysis of the learning curve in robot-assisted rectal cancer surgery, 7 were case series and 2 were non-randomised case-comparison series. Eight papers used the cumulative sum (CUSUM) method, and only one author divided the series into two groups to compare both. The mean number of cases for phase I of the learning curve was calculated to be 29.7 patients; phase II corresponds to a mean number 37.4 patients. The mean number of cases required for the surgeon to be classed as an expert in robotic surgery was calculated to be 39 patients. Robotic advantages could have an impact on learning curve for rectal cancer and lower the number of cases that are necessary for rectal resections.

  4. Study on rectal administration of azithromycin by suppository for pediatric use.

    PubMed

    Maeda, Miyuki; Nakano, Yukitaka; Aoyama, Takahiko; Matsumoto, Yoshiaki; Fujito, Hiroshi

    2016-04-01

    Azithromycin (AZM) is widely used as a first-line treatment option for children with mycoplasma pneumonia. Although pharmacists perform medication counseling in the pediatric ward, children often experience vomiting as a result of oral AZM administration. Drugs that are administered rectally are generally considered to enter the circulation system without passing through the liver first. The aim of our study was to prepare an AZM suppository and investigate the pharmaceutical properties and well as pharmacokinetics of the rectal administration route in humans. Five healthy volunteers were enrolled in the study. All subjects provided written informed consent before participating in the study. Subjects were randomly assigned to either oral administration of oral AZM 500-mg tablet or rectal administration of 125-mg, 250-mg, or 500-mg AZM suppository. Blood samples for preparation of serum were collected predose as well as at 1, 2, 3, 4, 6, 12, and 24 hours following the first rectal dose. Serum concentrations of AZM were determined by high-performance liquid chromatography (HPLC) with electrochemical detection. The bioavailability of the AZM suppository through rectal administration was 20.3% compared to oral administration. We hypothesize that the surface area where AZM is absorbed also affects the absorption by rectal administration. Although further investigation is necessary to improve the absorption of AZM by the rectum and to ensure safety in children, the AZM suppository may be an effective preparation in cases where oral administration is not tolerated.

  5. Systematic review of prognostic importance of extramural venous invasion in rectal cancer

    PubMed Central

    Chand, Manish; Siddiqui, Muhammed RS; Swift, Ian; Brown, Gina

    2016-01-01

    AIM: To systematically review the survival outcomes relating to extramural venous invasion in rectal cancer. METHODS: A systematic review was conducted using PRISMA guidelines. An electronic search was carried out using MEDLINE, EMBASE, CINAHL, Cochrane library databases, Google scholar and PubMed until October 2014. Search terms were used in combination to yield articles on extramural venous invasion in rectal cancer. Outcome measures included prevalence and 5-year survival rates. These were graphically displayed using Forest plots. Statistical analysis of the data was carried out. RESULTS: Fourteen studies reported the prevalence of extramural venous invasion (EMVI) positive patients. Prevalence ranged from 9%-61%. The pooled prevalence of EMVI positivity was 26% [Random effects: Event rate 0.26 (0.18, 0.36)]. Most studies showed that EMVI related to worse oncological outcomes. The pooled overall survival was 39.5% [Random effects: Event rate 0.395 (0.29, 0.51)]. CONCLUSION: Historically, there has been huge variation in the prevalence of EMVI through inconsistent reporting. However the presence of EMVI clearly leads to worse survival outcomes. As detection rates become more consistent, EMVI may be considered as part of risk-stratification in rectal cancer. Standardised histopathological definitions and the use of magnetic resonance imaging to identify EMVI will improve detection rates in the future. PMID:26819536

  6. The Kelvin and Temperature Measurements

    PubMed Central

    Mangum, B. W.; Furukawa, G. T.; Kreider, K. G.; Meyer, C. W.; Ripple, D. C.; Strouse, G. F.; Tew, W. L.; Moldover, M. R.; Johnson, B. Carol; Yoon, H. W.; Gibson, C. E.; Saunders, R. D.

    2001-01-01

    The International Temperature Scale of 1990 (ITS-90) is defined from 0.65 K upwards to the highest temperature measurable by spectral radiation thermometry, the radiation thermometry being based on the Planck radiation law. When it was developed, the ITS-90 represented thermodynamic temperatures as closely as possible. Part I of this paper describes the realization of contact thermometry up to 1234.93 K, the temperature range in which the ITS-90 is defined in terms of calibration of thermometers at 15 fixed points and vapor pressure/temperature relations which are phase equilibrium states of pure substances. The realization is accomplished by using fixed-point devices, containing samples of the highest available purity, and suitable temperature-controlled environments. All components are constructed to achieve the defining equilibrium states of the samples for the calibration of thermometers. The high quality of the temperature realization and measurements is well documented. Various research efforts are described, including research to improve the uncertainty in thermodynamic temperatures by measuring the velocity of sound in gas up to 800 K, research in applying noise thermometry techniques, and research on thermocouples. Thermometer calibration services and high-purity samples and devices suitable for “on-site” thermometer calibration that are available to the thermometry community are described. Part II of the paper describes the realization of temperature above 1234.93 K for which the ITS-90 is defined in terms of the calibration of spectroradiometers using reference blackbody sources that are at the temperature of the equilibrium liquid-solid phase transition of pure silver, gold, or copper. The realization of temperature from absolute spectral or total radiometry over the temperature range from about 60 K to 3000 K is also described. The dissemination of the temperature scale using radiation thermometry from NIST to the customer is achieved by

  7. Development of a synoptic MRI report for primary rectal cancer.

    PubMed

    Spiegle, Gillian; Leon-Carlyle, Marisa; Schmocker, Selina; Fruitman, Mark; Milot, Laurent; Gagliardi, Anna R; Smith, Andy J; McLeod, Robin S; Kennedy, Erin D

    2009-12-02

    Although magnetic resonance imaging (MRI) is an important imaging modality for pre-operative staging and surgical planning of rectal cancer, to date there has been little investigation on the completeness and overall quality of MRI reports. This is important because optimal patient care depends on the quality of the MRI report and clear communication of these reports to treating physicians. Previous work has shown that the use of synoptic pathology reports improves the quality of pathology reports and communication between physicians. The aims of this project are to develop a synoptic MRI report for rectal cancer and determine the enablers and barriers toward the implementation of a synoptic MRI report for rectal cancer in the clinical setting. A three-step Delphi process with an expert panel will extract the key criteria for the MRI report to guide pre-operative chemoradiation and surgical planning following a review of the literature, and a synoptic template will be developed. Furthermore, standardized qualitative research methods will be used to conduct interviews with radiologists to determine the enablers and barriers to the implementation and sustainability of the synoptic MRI report in the clinic setting. Synoptic MRI reports for rectal cancer are currently not used in North America and may improve the overall quality of MRI report and communication between physicians. This may, in turn, lead to improved patient care and outcomes for rectal cancer patients.

  8. Rectal 5-aminosalicylic acid for maintenance of remission in ulcerative colitis.

    PubMed

    Marshall, John K; Thabane, Marroon; Steinhart, A Hillary; Newman, Jamie R; Anand, Anju; Irvine, E Jan

    2012-11-14

    5-Aminosalicylic acid (5-ASA) is a first-line therapy for inducing and maintaining remission of mild and moderately active ulcerative colitis (UC). When the proximal margin of inflammation is distal to the splenic flexure, 5-ASA therapy can be delivered as a rectal suppository, foam or liquid enema. The primary objective was to assess the efficacy and safety of rectal 5-ASA for maintaining remission of distal UC. We searched MEDLINE (1966 to August 2012), the Cochrane Library (August 2012), abstracts from major gastroenterology meetings (1997-2011) and bibliographies of relevant publications to identify relevant studies. Eligible studies were randomized controlled trials comparing rectal 5-ASA to placebo or another active treatment for a minimum duration of six months. Symptom scores needed to be assessed in at least one study outcome. Patients had to be at least 12 years of age with disease extent less than 60 cm from the anal verge or distal to the splenic flexure, as determined by barium enema, colonoscopy or sigmoidoscopy. Patients were expected to be in remission prior to the treatment trial. Study eligibility was independently assessed by three authors. Data were extracted using standardized forms by two independent reviewers, with inter-rater agreement assessed using Cohen's Kappa and disagreements resolved by consensus. In cases where clarification of study results or methodology was needed, corresponding authors were contacted. The methodological quality of each trial was assessed by the Cochrane risk of bias tool and by a 30-point scale developed and used previously by the authors. Pooled risk ratios (RR) and corresponding 95% confidence intervals (CI) for continued clinical, endoscopic and histologic remission were estimated for comparisons between rectal 5-ASA and placebo or oral 5-ASA, and for comparisons among 5-ASA doses. Heterogeneity was assessed using the Chi(2) test and visual inspection of forest plots. If no significant heterogeneity was

  9. The colostomy impact score: development and validation of a patient reported outcome measure for rectal cancer patients with a permanent colostomy. A population-based study.

    PubMed

    Thyø, A; Emmertsen, K J; Pinkney, T D; Christensen, P; Laurberg, S

    2017-01-01

    The aim was to develop and validate a simple scoring system evaluating the impact of colostomy dysfunction on quality of life (QOL) in patients with a permanent stoma after rectal cancer treatment. In this population-based study, 610 patients with a permanent colostomy after previous rectal cancer treatment during the period 2001-2007 completed two questionnaires: (i) the basic stoma questionnaire consisting of 22 items about stoma function with one anchor question addressing the overall stoma impact on QOL and (ii) the European Organization for Research and Treatment of Cancer Quality of Life Questionnaire (EORTC QLQ) C30. Answers from half of the cohort were used to develop the score and subsequently validated on the remaining half. Logistic regression analyses identified and selected items for the score and multivariate analysis established the score value allocated to each item. The colostomy impact score includes seven items with a total range from 0 to 38 points. A score of ≥ 10 indicates major colostomy impact (Major CI). The score has a sensitivity of 85.7% for detecting patients with significant stoma impact on QOL. Using the EORTC QLQ scales, patients with Major CI experienced significant impairment in their QOL compared to the Minor CI group. This new scoring system appears valid for the assessment of the impact on QOL from having a permanent colostomy in a Danish rectal cancer population. It requires validation in non-Danish populations prior to its acceptance as a valuable patient-reported outcome measure for patients internationally. Colorectal Disease © 2016 The Association of Coloproctology of Great Britain and Ireland.

  10. Free-breathing diffusion-weighted single-shot echo-planar MR imaging using parallel imaging (GRAPPA 2) and high b value for the detection of primary rectal adenocarcinoma.

    PubMed

    Soyer, Philippe; Lagadec, Matthieu; Sirol, Marc; Dray, Xavier; Duchat, Florent; Vignaud, Alexandre; Fargeaudou, Yann; Placé, Vinciane; Gault, Valérie; Hamzi, Lounis; Pocard, Marc; Boudiaf, Mourad

    2010-02-11

    Our objective was to determine the diagnostic accuracy of a free-breathing diffusion-weighted single-shot echo-planar magnetic resonance imaging (FBDW-SSEPI) technique with parallel imaging and high diffusion factor value (b = 1000 s/mm2) in the detection of primary rectal adenocarcinomas. Thirty-one patients (14M and 17F; mean age 67 years) with histopathologically proven primary rectal adenocarcinomas and 31 patients without rectal malignancies (14M and 17F; mean age 63.6 years) were examined with FBDW-SSEPI (repetition time (TR/echo time (TE) 3900/91 ms, gradient strength 45 mT/m, acquisition time 2 min) at 1.5 T using generalized autocalibrating partially parallel acquisitions (GRAPPA, acceleration factor 2) and a b value of 1000 s/mm2. Apparent diffusion coefficients (ADCs) of rectal adenocarcinomas and normal rectal wall were measured. FBDW-SSEPI images were evaluated for tumour detection by 2 readers. Sensitivity, specificity, accuracy and Youden score for rectal adenocarcinoma detection were calculated with their 95% confidence intervals (CI) for ADC value measurement and visual image analysis. Rectal adenocarcinomas had significantly lower ADCs (mean 1.036 x 10(-3)+/- 0.107 x 10(-3) mm2/s; median 1.015 x 10(-3) mm2/s; range (0.827-1.239) x 10(-3) mm2/s) compared with the rectal wall of control subjects (mean 1.387 x 10(-3)+/- 0.106 x 10(-3) mm2/s; median 1.385 x 10(-3) mm2/s; range (1.176-1.612) x 10(-3) mm2/s) (p < 0.0001). Using a threshold value < or = 1.240 x 10(-3) mm2/s, all rectal adenocarcinomas were correctly categorized and 100% sensitivity (31/31; 95% CI 95-100%), 94% specificity (31/33; 95% CI 88-100%), 97% accuracy (60/62; 95% CI 92-100%) and Youden index 0.94 were obtained for the diagnosis of rectal adenocarcinoma. FBDW-SSEPI image analysis allowed depiction of all rectal adenocarcinomas but resulted in 2 false-positive findings, yielding 100% sensitivity (31/31; 95% CI 95-100%), 94% specificity (31/33; 95% CI 88-100%), 97% accuracy (60

  11. High-Sensitivity Temperature Measurement

    ERIC Educational Resources Information Center

    Leadstone, G. S.

    1978-01-01

    Describes a method of measuring small temperature differences that amount to a .01K, using an arrangement of a copper-constantan thermocouple, a microamplifier and a galvanometer, as an indirect way of measuring heat energy. (GA)

  12. Surface Temperature Measurement Using Hematite Coating

    NASA Technical Reports Server (NTRS)

    Bencic, Timothy J. (Inventor)

    2015-01-01

    Systems and methods that are capable of measuring temperature via spectrophotometry principles are discussed herein. These systems and methods are based on the temperature dependence of the reflection spectrum of hematite. Light reflected from these sensors can be measured to determine a temperature, based on changes in the reflection spectrum discussed herein.

  13. Rectal squamous cell carcinoma in immunosuppressed populations: is this a distinct entity from anal cancer?

    PubMed Central

    COGHILL, Anna E.; SHIELS, Meredith S.; RYCROFT, Randi K.; COPELAND, Glenn; FINCH, Jack L.; HAKENEWERTH, Anne M.; PAWLISH, Karen S.; ENGELS, Eric A.

    2015-01-01

    Objective Squamous cell carcinoma (SCC) of the rectum is rare, but as with anal cancer, risk may be increased among immunosuppressed individuals. We assessed risk of rectal SCC in HIV-infected people. Design Population-based registry Methods We utilized the HIV/AIDS Cancer Match, a linkage of US HIV and cancer registries (1991–2010), to ascertain cases of anal SCC, rectal SCC, rectal non-SCC, and colon non-SCC. We compared risk in HIV-infected persons to the general population using standardized incidence ratios (SIRs) and evaluated risk factors using Poisson regression. We reviewed cancer registry case notes to confirm site and histology for a subset of cases. Results HIV-infected persons had an excess risk of rectal SCC compared to the general population (SIR=28.9; 95%CI 23.2–35.6), similar to the increase for anal SCC (SIR=37.3). Excess rectal SCC risk was most pronounced among HIV-infected men who have sex with men (MSM, SIR=61.2). Risk was not elevated for rectal non-SCC (SIR=0.88) or colon non-SCC (SIR=0.63). Individuals diagnosed with AIDS had higher rectal SCC rates than those with HIV-only (incidence rate ratio=1.86; 95%CI 1.04–3.31). Based on available information, one-third of rectal SCCs were determined to be misclassified anal cancer. Conclusions HIV-infected individuals, especially with advanced immunosuppression, appear to have substantially elevated risk for rectal SCC. As for anal SCC, rectal SCC risk was highest in MSM, pointing to involvement of a sexually transmitted infection such as human papillomavirus. Site misclassification was present, and detailed information on tumor location is needed to prove that rectal SCC is a distinct entity. PMID:26372482

  14. Robotic surgery for rectal cancer: Current immediate clinical and oncological outcomes

    PubMed Central

    Araujo, Sergio Eduardo Alonso; Seid, Victor Edmond; Klajner, Sidney

    2014-01-01

    Laparoscopic rectal surgery continues to be a challenging operation associated to a steep learning curve. Robotic surgical systems have dramatically changed minimally invasive surgery. Three-dimensional, magnified and stable view, articulated instruments, and reduction of physiologic tremors leading to superior dexterity and ergonomics. Therefore, robotic platforms could potentially address limitations of laparoscopic rectal surgery. It was aimed at reviewing current literature on short-term clinical and oncological (pathological) outcomes after robotic rectal cancer surgery in comparison with laparoscopic surgery. A systematic review was performed for the period 2002 to 2014. A total of 1776 patients with rectal cancer underwent minimally invasive robotic treatment in 32 studies. After robotic and laparoscopic approach to oncologic rectal surgery, respectively, mean operating time varied from 192-385 min, and from 158-297 min; mean estimated blood loss was between 33 and 283 mL, and between 127 and 300 mL; mean length of stay varied from 4-10 d; and from 6-15 d. Conversion after robotic rectal surgery varied from 0% to 9.4%, and from 0 to 22% after laparoscopy. There was no difference between robotic (0%-41.3%) and laparoscopic (5.5%-29.3%) surgery regarding morbidity and anastomotic complications (respectively, 0%-13.5%, and 0%-11.1%). Regarding immediate oncologic outcomes, respectively among robotic and laparoscopic cases, positive circumferential margins varied from 0% to 7.5%, and from 0% to 8.8%; the mean number of retrieved lymph nodes was between 10 and 20, and between 11 and 21; and the mean distal resection margin was from 0.8 to 4.7 cm, and from 1.9 to 4.5 cm. Robotic rectal cancer surgery is being undertaken by experienced surgeons. However, the quality of the assembled evidence does not support definite conclusions about most studies variables. Robotic rectal cancer surgery is associated to increased costs and operating time. It also seems to be

  15. Robotic surgery for rectal cancer: current immediate clinical and oncological outcomes.

    PubMed

    Araujo, Sergio Eduardo Alonso; Seid, Victor Edmond; Klajner, Sidney

    2014-10-21

    Laparoscopic rectal surgery continues to be a challenging operation associated to a steep learning curve. Robotic surgical systems have dramatically changed minimally invasive surgery. Three-dimensional, magnified and stable view, articulated instruments, and reduction of physiologic tremors leading to superior dexterity and ergonomics. Therefore, robotic platforms could potentially address limitations of laparoscopic rectal surgery. It was aimed at reviewing current literature on short-term clinical and oncological (pathological) outcomes after robotic rectal cancer surgery in comparison with laparoscopic surgery. A systematic review was performed for the period 2002 to 2014. A total of 1776 patients with rectal cancer underwent minimally invasive robotic treatment in 32 studies. After robotic and laparoscopic approach to oncologic rectal surgery, respectively, mean operating time varied from 192-385 min, and from 158-297 min; mean estimated blood loss was between 33 and 283 mL, and between 127 and 300 mL; mean length of stay varied from 4-10 d; and from 6-15 d. Conversion after robotic rectal surgery varied from 0% to 9.4%, and from 0 to 22% after laparoscopy. There was no difference between robotic (0%-41.3%) and laparoscopic (5.5%-29.3%) surgery regarding morbidity and anastomotic complications (respectively, 0%-13.5%, and 0%-11.1%). Regarding immediate oncologic outcomes, respectively among robotic and laparoscopic cases, positive circumferential margins varied from 0% to 7.5%, and from 0% to 8.8%; the mean number of retrieved lymph nodes was between 10 and 20, and between 11 and 21; and the mean distal resection margin was from 0.8 to 4.7 cm, and from 1.9 to 4.5 cm. Robotic rectal cancer surgery is being undertaken by experienced surgeons. However, the quality of the assembled evidence does not support definite conclusions about most studies variables. Robotic rectal cancer surgery is associated to increased costs and operating time. It also seems to be

  16. Rectal misoprostol in management of retained placenta: a contradictory result.

    PubMed

    Pongsatha, Saipin; Tongsong, Theera

    2011-05-01

    Retained placenta is one of the common problems in obstetric practice. The most common procedure to manage cases with retained placenta is manual removal of placenta (MROP) under general anesthesia. Recent data indicates that misoprostol may be helpful in decreasing the rate of MROP. To assess the efficacy of rectal misoprostol in women with delayed placental separation. A descriptive, retrospective cohort was conducted. All pregnant women with retained placenta longer than 30 minutes after fetal delivery, either in second or third trimester that received 800 mcg rectal misoprostol were included in the present study. Successful treatment was defined as spontaneous placental expulsion within 30 minutes after rectal misoprostol administration. The rate of spontaneous placental expulsion within 30 minutes after misoprostol administration was very low, only three out of 20 cases (15%). High dose rectal misoprostol does not give a promising result in cases of retained placenta. It is ineffective to facilitate placental separation in cases of retained placenta and does not seem to decrease the rate of MROP.

  17. Implementation of a hospital-based quality assessment program for rectal cancer.

    PubMed

    Hendren, Samantha; McKeown, Ellen; Morris, Arden M; Wong, Sandra L; Oerline, Mary; Poe, Lyndia; Campbell, Darrell A; Birkmeyer, Nancy J

    2014-05-01

    Quality improvement programs in Europe have had a markedly beneficial effect on the processes and outcomes of rectal cancer care. The quality of rectal cancer care in the United States is not as well understood, and scalable quality improvement programs have not been developed. The purpose of this article is to describe the implementation of a hospital-based quality assessment program for rectal cancer, targeting both community and academic hospitals. We recruited 10 hospitals from a surgical quality improvement organization. Nurse reviewers were trained to abstract rectal cancer data from hospital medical records, and abstracts were assessed for accuracy. We conducted two surveys to assess the training program and limitations of the data abstraction. We validated data completeness and accuracy by comparing hospital medical record and tumor registry data. Nine of 10 hospitals successfully performed abstractions with ≥ 90% accuracy. Experienced nurse reviewers were challenged by the technical details in operative and pathology reports. Although most variables had less than 10% missing data, outpatient testing information was lacking from some hospitals' inpatient records. This implementation project yielded a final quality assessment program consisting of 20 medical records variables and 11 tumor registry variables. An innovative program linking tumor registry data to quality-improvement data for rectal cancer quality assessment was successfully implemented in 10 hospitals. This data platform and training program can serve as a template for other organizations that are interested in assessing and improving the quality of rectal cancer care. Copyright © 2014 by American Society of Clinical Oncology.

  18. Postoperative adjuvant chemotherapy in rectal cancer operated for cure.

    PubMed

    Petersen, Sune Høirup; Harling, Henrik; Kirkeby, Lene Tschemerinsky; Wille-Jørgensen, Peer; Mocellin, Simone

    2012-03-14

    Colorectal cancer is one of the most common types of cancer in the Western world. Apart from surgery - which remains the mainstay of treatment for resectable primary tumours - postoperative (i.e., adjuvant) chemotherapy with 5-fluorouracil (5-FU) based regimens is now the standard treatment in Dukes' C (TNM stage III) colon tumours i.e. tumours with metastases in the regional lymph nodes but no distant metastases. In contrast, the evidence for recommendations of adjuvant therapy in rectal cancer is sparse. In Europe it is generally acknowledged that locally advanced rectal tumours receive preoperative (i.e., neoadjuvant) downstaging by radiotherapy (or chemoradiotion), whereas in the US postoperative chemoradiotion is considered the treatment of choice in all Dukes' C rectal cancers. Overall, no universal consensus exists on the adjuvant treatment of surgically resectable rectal carcinoma; moreover, no formal systematic review and meta-analysis has been so far performed on this subject. We undertook a systematic review of the scientific literature from 1975 until March 2011 in order to quantitatively summarize the available evidence regarding the impact of postoperative adjuvant chemotherapy on the survival of patients with surgically resectable rectal cancer. The outcomes of interest were overall survival (OS) and disease-free survival (DFS). CCCG standard search strategy in defined databases with the following supplementary search. 1. Rect* or colorect* - 2. Cancer or carcinom* or adenocarc* or neoplasm* or tumour - 3. Adjuv* - 4. Chemother* - 5. Postoper* Randomised controlled trials (RCT) comparing patients undergoing surgery for rectal cancer who received no adjuvant chemotherapy with those receiving any postoperative chemotherapy regimen. Two authors extracted data and a third author performed an independent search for verification. The main outcome measure was the hazard ratio (HR) between the risk of event between the treatment arm (adjuvant chemotherapy

  19. Preoperative neo-adjuvant therapy for curable rectal cancer--reaching a consensus 2008.

    PubMed

    Scott, N A; Susnerwala, S; Gollins, S; Myint, A Sun; Levine, E

    2009-03-01

    Our aim was to determine the range of neo-adjuvant therapy the multidisciplinary team (MDT) currently offers patients with curable (M(0)) rectal cancer. A senior oncologist from each of the four oncology centres in north Wales and the north-west of England (approximate target population 8 million - Glan Clwyd, Clatterbridge, Christie and Preston) reviewed his/her understanding of the current evidence of neo-adjuvant therapy in rectal cancer. Then a representative from each centre was asked to identify which of three neo-adjuvant options (no neo-adjuvant therapy, short-course radiotherapy 25 Gy over five fractions and long-course chemoradiotherapy) he/she would use for a rectal cancer in the upper, middle or lower third of the rectum staged by magnetic resonance imaging as being T(2)-T(4) and/or N(0)-N(2). In all cases of locally advanced rectal cancer (T(3a) N(1)-T(4)), oncologists from the four oncology centres recommended long-course chemoradiotherapy before rectal resection. This consensus was maintained for cases of lower third T(3a) N(0) cancers. Thereafter, the majority of patients with rectal cancer are offered adjuvant short-course radiotherapy. Neo-adjuvant therapy is less likely to be offered if the tumour is early (T(2), N(0)) and/or situated in the upper third of the rectum.

  20. Rectal ulcer in a patient with VZV sacral meningoradiculitis (Elsberg syndrome).

    PubMed

    Matsumoto, Hideyuki; Shimizu, Takahiro; Tokushige, Shin-ichi; Mizuno, Hideo; Igeta, Yukifusa; Hashida, Hideji

    2012-01-01

    This report describes the case of a 55-year-old woman with varicella-zoster virus (VZV) sacral meningoradiculitis (Elsberg syndrome) who presented with herpes zoster in the left S2 dermatome area, urinary retention, and constipation. Lumbar magnetic resonance imaging showed the left sacral nerve root swelling with enhancement. Thereafter, she suddenly showed massive hematochezia and hemorrhagic shock because of a rectal ulcer. To elucidate the relation between Elsberg syndrome and rectal ulcer, accumulation of similar cases is necessary. To avoid severe complications, attention must be devoted to the possibility of rectal bleeding in the early stage of Elsberg syndrome.

  1. Expression of fibulin-5 in the skin of patients with rectal prolapse.

    PubMed

    Joshi, H M; Gosselink, M P; Smyth, E A; Hompes, R; Cunningham, C; Lindsey, I; Urban, J; Jones, O M

    2015-11-01

    Components of connective tissue other than collagen have been found to be involved in patients with rectal prolapse. The organization of elastic fibres differs between controls and subsets of patients with rectal prolapse, and their importance for maintaining the structural and functional integrity of the pelvic floor has been demonstrated in transgenic mice, with animals which have a null mutation in fibulin-5 (Fbln5(i/i)) developing prolapse. This study aimed to compare fibulin-5 expression in the skin of patients with and without rectal prolapse. Between January 2013 and February 2014, skin specimens were obtained during surgery from 20 patients with rectal prolapse and from 21 without prolapse undergoing surgery for other indications. Fibroblasts from the skin were cultured and the level of fibulin-5 expression was determined on cultured fibroblasts, isolated from these specimens by quantitative real-time polymerase chain reaction. Immunohistochemistry was performed on fixed tissue specimens to assess fibulin-5 expression. Fibulin-5 mRNA expression and fibulin-5 staining intensity were significantly lower in young male patients with rectal prolapse compared with age-matched controls [fibulin-5 mean ± SD mRNA relative units, 1.1 ± 0.41 vs 0.53 ± 0.22, P = 0.001; intensity score, median (range), 2 (0-3) vs 1 (0-3), P = 0.05]. There were no significant differences in the expression of fibulin-5 in women with rectal prolapse compared with controls. Fibulin-5 may be implicated in the aetiology of rectal prolapse in a subgroup of young male patients. Colorectal Disease © 2015 The Association of Coloproctology of Great Britain and Ireland.

  2. Genetic Mutations in Blood and Tissue Samples in Predicting Response to Treatment in Patients With Locally Advanced Rectal Cancer Undergoing Chemoradiation

    ClinicalTrials.gov

    2017-09-08

    Mucinous Adenocarcinoma of the Rectum; Recurrent Rectal Cancer; Signet Ring Adenocarcinoma of the Rectum; Stage IIA Rectal Cancer; Stage IIB Rectal Cancer; Stage IIC Rectal Cancer; Stage IIIA Rectal Cancer; Stage IIIB Rectal Cancer; Stage IIIC Rectal Cancer

  3. Understanding post-operative temperature drop in cardiac surgery: a mathematical model.

    PubMed

    Tindall, M J; Peletier, M A; Severens, N M W; Veldman, D J; de Mol, B A J M

    2008-12-01

    A mathematical model is presented to understand heat transfer processes during the cooling and re-warming of patients during cardiac surgery. Our compartmental model is able to account for many of the qualitative features observed in the cooling of various regions of the body including the central core containing the majority of organs, the rectal region containing the intestines and the outer peripheral region of skin and muscle. In particular, we focus on the issue of afterdrop: a drop in core temperature following patient re-warming, which can lead to serious post-operative complications. Model results for a typical cooling and re-warming procedure during surgery are in qualitative agreement with experimental data in producing the afterdrop effect and the observed dynamical variation in temperature between the core, rectal and peripheral regions. The influence of heat transfer processes and the volume of each compartmental region on the afterdrop effect is discussed. We find that excess fat on the peripheral and rectal regions leads to an increase in the afterdrop effect. Our model predicts that, by allowing constant re-warming after the core temperature has been raised, the afterdrop effect will be reduced.

  4. Interleukin genes and associations with colon and rectal cancer risk and overall survival

    PubMed Central

    Bondurant, Kristina L.; Lundgreen, Abbie; Herrick, Jennifer S.; Kadlubar, Susan; Wolff, Roger K.; Slattery, Martha L.

    2012-01-01

    Interleukins are a group of cytokines that contribute to growth and differentiation, cell migration, and inflammatory and anti-inflammatory responses by the immune system. In this study we examined genetic variation in genes from various anti-inflammatory and pro-inflammatory interleukins to determine association with colon and rectal cancer risk and overall survival. Data from two population-based incident studies of colon cancer (1555 cases and 1956 controls) and rectal cancer (754 cases and 954 controls) were utilized. After controlling for multiple comparisons, single nucleotide polymorphisms (SNPs) from four genes, IL3, IL6R, IL8, IL15, were associated with increased colon cancer risk and CXCR1, and CXCR2 were significantly associated with increased rectal cancer risk. Only SNPs from genes within the IL-8 pathway (IL8, CXCR1, and CXCR2) showed a significant association with both colon and rectal cancer risk. Several SNPs interacted significantly with IL8 and IFNG SNPs and with aspirin/NSAID, cigarette smoking, estrogen use and BMI. For both colon and rectal cancer, increasing numbers of risk alleles were associated with increased hazard of death from cancer; the estimated hazard of death for colon cancer for the highest category of risk alleles was 1.74 (95% CI 1.18–2.56) and 1.96 (95% CI 1.28–2.99) for rectal cancer. These data suggest interleukin genes play a role in risk and overall survival for colon and rectal cancer. PMID:22674296

  5. High environmental temperature around farrowing induced heat stress in crated sows.

    PubMed

    Muns, R; Malmkvist, J; Larsen, M L V; Sørensen, D; Pedersen, L J

    2016-01-01

    The aim of the experiment was to study the impact of high ambient temperature (25°C) around farrowing on crated sows unable to perform thermoregulatory behavior. Twenty sows were housed in 2 farrowing rooms in conventional farrowing crates. In 1 room (CONTROL) temperature was kept at 20°C. In the other room (HEAT) temperature was initially kept at 20°C and gradually raised until it reached 25°C from d 112 to 115 of gestation. Then the temperature was gradually lowered to 20°C. Sows were continuously video recorded for behavior recording. Sows' respiration rates were recorded from d 3 before farrowing to d 5 after farrowing. Sows' rectal temperatures were recorded from d 1 before farrowing to d 8 after farrowing, and sows' udder surface temperatures were recorded from the day of farrowing to d 3 after farrowing. All measures were recorded daily. Sows' BW were recorded at d 108 of gestation and at weaning. Sows' back fat was recorded on farrowing day, when room temperature was set again at 20°C, and at weaning. Piglets were weighed at d 1, 14, and 21. The HEAT sows spent a higher proportion of time lying in the lateral position than CONTROL sows, both during the 16 h before farrowing and the 24 h after the start of farrowing ( < 0.05), but with no difference in the amount of time spent lying down between groups ( > 0.10). The HEAT sows had higher rectal temperature on d 1 after farrowing ( < 0.05) and had udder surface temperature 0.9°C higher than that of CONTROL sows during the recording period ( < 0.05). The HEAT sows also tended to have longer farrowing duration ( < 0.10). Respiration rate was higher in HEAT sows on d 1 before farrowing and on the day of farrowing. On d 7, 8, and 9, CONTROL sows had higher feed intake ( < 0.05), and piglets from CONTROL sows were heavier at d 21 after farrowing ( < 0.05). High ambient temperature around farrowing altered sows' postural behavior. Sows reacted to the thermal challenge with higher respiration rate around

  6. A Temperature-Stable Cryo-System for High-Temperature Superconducting MR In-Vivo Imaging

    PubMed Central

    Lin, In-Tsang; Yang, Hong-Chang; Chen, Jyh-Horng

    2013-01-01

    To perform a rat experiment using a high-temperature superconducting (HTS) surface resonator, a cryostat is essential to maintain the rat's temperature. In this work, a compact temperature-stable HTS cryo-system, keeping animal rectal temperature at 37.4°C for more than 3 hours, was successfully developed. With this HTS cryo-system, a 40-mm-diameter Bi2Sr2Ca2Cu3Ox (Bi-2223) surface resonator at 77 K was demonstrated in a 3-Tesla MRI system. The proton resonant frequency (PRF) method was employed to monitor the rat's temperature. Moreover, the capacity of MR thermometry in the HTS experiments was evaluated by correlating with data from independent fiber-optic sensor temperature measurements. The PRF thermal coefficient was derived as 0.03 rad/°C and the temperature-monitoring architecture can be implemented to upgrade the quality and safety in HTS experiments. The signal-to-noise ratio (SNR) of the HTS surface resonator at 77 K was higher than that of a professionally made copper surface resonator at 300 K, which has the same geometry, by a 3.79-fold SNR gain. Furthermore, the temperature-stable HTS cryo-system we developed can obtain stable SNR gain in every scan. A temperature-stable HTS cryo-system with an external air-blowing circulation system is demonstrated. PMID:23637936

  7. The association of rectal equivalent dose in 2 Gy fractions (EQD2) to late rectal toxicity in locally advanced cervical cancer patients who were evaluated by rectosigmoidoscopy in Faculty of Medicine, Chiang Mai University.

    PubMed

    Tharavichtikul, Ekkasit; Meungwong, Pooriwat; Chitapanarux, Taned; Chakrabandhu, Somvilai; Klunklin, Pitchayaponne; Onchan, Wimrak; Wanwilairat, Somsak; Traisathit, Patrinee; Galalae, Razvan; Chitapanarux, Imjai

    2014-06-01

    To evaluate association between equivalent dose in 2 Gy (EQD2) to rectal point dose and gastrointestinal toxicity from whole pelvic radiotherapy (WPRT) and intracavitary brachytherapy (ICBT) in cervical cancer patients who were evaluated by rectosigmoidoscopy in Faculty of Medicine, Chiang Mai University. Retrospective study was designed for the patients with locally advanced cervical cancer, treated by radical radiotherapy from 2004 to 2009 and were evaluated by rectosigmoidoscopy. The cumulative doses of WPRT and ICBT to the maximally rectal point were calculated to the EQD2 and evaluated the association of toxicities. Thirty-nine patients were evaluated for late rectal toxicity. The mean cumulative dose in term of EQD2 to rectum was 64.2 Gy. Grade 1 toxicities were the most common findings. According to endoscopic exam, the most common toxicities were congested mucosa (36 patients) and telangiectasia (32 patients). In evaluation between rectal dose in EQD2 and toxicities, no association of cumulative rectal dose to rectal toxicity, except the association of cumulative rectal dose in EQD2 >65 Gy to late effects of normal tissue (LENT-SOMA) scale ≥ grade 2 (p = 0.022; odds ratio, 5.312; 95% confidence interval, 1.269-22.244). The cumulative rectal dose in EQD2 >65 Gy have association with ≥ grade 2 LENT-SOMA scale.

  8. The association of rectal equivalent dose in 2 Gy fractions (EQD2) to late rectal toxicity in locally advanced cervical cancer patients who were evaluated by rectosigmoidoscopy in Faculty of Medicine, Chiang Mai University

    PubMed Central

    Meungwong, Pooriwat; Chitapanarux, Taned; Chakrabandhu, Somvilai; Klunklin, Pitchayaponne; Onchan, Wimrak; Wanwilairat, Somsak; Traisathit, Patrinee; Galalae, Razvan; Chitapanarux, Imjai

    2014-01-01

    Purpose To evaluate association between equivalent dose in 2 Gy (EQD2) to rectal point dose and gastrointestinal toxicity from whole pelvic radiotherapy (WPRT) and intracavitary brachytherapy (ICBT) in cervical cancer patients who were evaluated by rectosigmoidoscopy in Faculty of Medicine, Chiang Mai University. Materials and Methods Retrospective study was designed for the patients with locally advanced cervical cancer, treated by radical radiotherapy from 2004 to 2009 and were evaluated by rectosigmoidoscopy. The cumulative doses of WPRT and ICBT to the maximally rectal point were calculated to the EQD2 and evaluated the association of toxicities. Results Thirty-nine patients were evaluated for late rectal toxicity. The mean cumulative dose in term of EQD2 to rectum was 64.2 Gy. Grade 1 toxicities were the most common findings. According to endoscopic exam, the most common toxicities were congested mucosa (36 patients) and telangiectasia (32 patients). In evaluation between rectal dose in EQD2 and toxicities, no association of cumulative rectal dose to rectal toxicity, except the association of cumulative rectal dose in EQD2 >65 Gy to late effects of normal tissue (LENT-SOMA) scale ≥ grade 2 (p = 0.022; odds ratio, 5.312; 95% confidence interval, 1.269-22.244). Conclusion The cumulative rectal dose in EQD2 >65 Gy have association with ≥ grade 2 LENT-SOMA scale. PMID:25061573

  9. Physiological responses to treadmill exercise and ambient temperature in normal and malignant hyperthermia susceptible pigs.

    PubMed Central

    D'Allaire, S; DeRoth, L

    1986-01-01

    Ten susceptible and ten resistant pigs to malignant hyperthermia were used to observe the effects of exercise and ambient temperature on selected physiological parameters. Pigs were submitted to a ten minute exercise on a treadmill operating at a speed of 1.8 km/h and inclined to 11 degrees. Exercise in the first group was at an ambient temperature of 14 degrees C, and in the second at 29 degrees C. The right carotid artery was previously cannulated for blood pressure measurements and for repeated blood sampling during exercise. Arterial pressure, heart rate, rectal and cutaneous temperatures were recorded. Levels of cortisol, creatine kinase and its isoenzymes were measured. At 14 degrees C, exercise caused some physiological adjustments in susceptible animals; heart rate, skin temperature and cortisol levels increased (P less than 0.05). In resistant pigs, only the heart rate was elevated significantly following exertional stress at 14 degrees C. Exercise at 29 degrees C produced severe stress and marked physiological changes: heart rate, rectal and skin temperatures and cortisol levels increased significantly in both susceptible and resistant swine. At 29 degrees C, susceptible pigs also had higher levels of serum cortisol, total creatine kinase and MM isoenzyme (P less than 0.05) compared to resistant pigs. The results indicate that, following exertional or thermal stress, susceptible pigs undergo more extensive physiological changes than do resistant pigs. Similar levels of stress prior to slaughter may trigger physiological changes which in the susceptible pigs would likely result in pale, soft exudative myopathy. PMID:3742362

  10. Rectal diazepam solution is as good as rectal administration of intravenous diazepam in the first-aid cessation of seizures in children with intractable epilepsy.

    PubMed

    Chiang, Lin-Mei; Wang, Huei-Shyong; Shen, Hsin-Hsien; Deng, Shin-Tang; Tseng, Chi-Hao; Chen, Yu-In; Chou, Ming-Liang; Hung, Po-Cheng; Lin, Kuang-Lin

    2011-02-01

    Acute seizures are readily recognizable episodes requiring urgent treatment. This study was conducted to compare the efficacy and safety of suppository use of rectal diazepam solution [Stesolid rectal tube (SRT), Alpharma, Inc., Lierskogen, Norway] with those of intravenous diazepam (IVD), Li Ta Pharma Co, Ltd., Taichung, Taiwan for control of acute seizures in children with intractable epilepsy. Subjects were patients, aged 1-18 years, with intractable epilepsy under at least three kinds of antiepileptic treatments. Caregivers were trained to rectally administer SRT or IVD (dosage varying from 0.2 to 0.5mg per kilogram of body weight) and to monitor respiration condition, seizure severity, and adverse drug effects. Among the 24 subjects, 9 males and 15 females, treated for a period of 3 months, the ages ranged from 2 to 18 years, with a mean of 9.1 years. Seizure types were generalized tonic and/or clonic. Seizure frequency varied from once per week to 20 times per day. Twenty-one (87.5%) of them had mental retardation and/or developmental delay, and 103 of the 127 (81.1%) IVD administrations and 90 of the 103 (87.3%) SRT administrations resulted in rapid cessation of seizures within 10 minutes. Each first dose failed to control seizures in 24 and 13 episodes, respectively. A second dose of IVD achieved cessation of seizure in 21 of the 24 episodes and a second dose of SRT in 12 of the 13 episodes within another 10 minutes. Four episodes (3 with rectal IVD and 1 with SRT) of prolonged seizure beyond 20 minutes needed IVD injection at our emergency room. Sedation occurred in 17% of patients, which was attributed to IVD in 8% and SRT in 9% of patients. No respiratory depression was attributable to IVD or SRT. There was no significant statistical difference in efficacy and safety between these two forms of diazepam. Rectal diazepam solution, administered by capable caregivers, is as effective and safe as rectal administration of IVD for children with intractable

  11. Purulent myositis of the thigh as a presentation of perforated low rectal cancer.

    PubMed

    Jenkins, V; Steinke, J; Rajendran, N; Kumar, D

    2018-03-01

    Purulent myositis is an acute, intramuscular bacterial infection involving abscess formation most commonly affecting the quadriceps, hamstring and gluteal muscles. We present a case of extensive purulent myositis of the thigh and lower leg caused by bowel perforation below the peritoneal reflection secondary to rectal cancer. Cases of lower limb and perineal purulent myositis should raise suspicion of rectal perforation and should prompt investigations to exclude rectal malignancy.

  12. Prediction of brain tissue temperature using near-infrared spectroscopy.

    PubMed

    Holper, Lisa; Mitra, Subhabrata; Bale, Gemma; Robertson, Nicola; Tachtsidis, Ilias

    2017-04-01

    Broadband near-infrared spectroscopy (NIRS) can provide an endogenous indicator of tissue temperature based on the temperature dependence of the water absorption spectrum. We describe a first evaluation of the calibration and prediction of brain tissue temperature obtained during hypothermia in newborn piglets (animal dataset) and rewarming in newborn infants (human dataset) based on measured body (rectal) temperature. The calibration using partial least squares regression proved to be a reliable method to predict brain tissue temperature with respect to core body temperature in the wavelength interval of 720 to 880 nm with a strong mean predictive power of [Formula: see text] (animal dataset) and [Formula: see text] (human dataset). In addition, we applied regression receiver operating characteristic curves for the first time to evaluate the temperature prediction, which provided an overall mean error bias between NIRS predicted brain temperature and body temperature of [Formula: see text] (animal dataset) and [Formula: see text] (human dataset). We discuss main methodological aspects, particularly the well-known aspect of over- versus underestimation between brain and body temperature, which is relevant for potential clinical applications.

  13. A comparison of hydration effect on body fluid and temperature regulation between Malaysian and Japanese males exercising at mild dehydration in humid heat

    PubMed Central

    2014-01-01

    Background This study investigated the effect of hydration differences on body fluid and temperature regulation between tropical and temperate indigenes exercising in the heat. Methods Ten Japanese and ten Malaysian males with matched physical characteristics (height, body weight, and peak oxygen consumption) participated in this study. Participants performed exercise for 60 min at 55% peak oxygen uptake followed by a 30-min recovery at 32°C and 70% relative air humidity with hydration (4 times each, 3 mL per kg body weight, 37°C) or without hydration. Rectal temperature, skin temperature, heart rate, skin blood flow, and blood pressure were measured continuously. The percentage of body weight loss and total sweat loss were calculated from body weight measurements. The percentage change in plasma volume was estimated from hemoglobin concentration and hematocrit. Results Malaysian participants had a significantly lower rectal temperature, a smaller reduction in plasma volume, and a lower heart rate in the hydrated condition than in the non-hydrated condition at the end of exercise (P <0.05), whereas Japanese participants showed no difference between the two hydration conditions. Hydration induced a greater total sweat loss in both groups (P <0.05), and the percentage of body weight loss in hydrated Malaysians was significantly less than in hydrated Japanese (P <0.05). A significant interaction between groups and hydration conditions was observed for the percentage of mean cutaneous vascular conductance during exercise relative to baseline (P <0.05). Conclusions The smaller reduction in plasma volume and percentage body weight loss in hydrated Malaysians indicated an advantage in body fluid regulation. This may enable Malaysians to reserve more blood for circulation and heat dissipation and thereby maintain lower rectal temperatures in a hydrated condition. PMID:24490869

  14. A comparison of hydration effect on body fluid and temperature regulation between Malaysian and Japanese males exercising at mild dehydration in humid heat.

    PubMed

    Wakabayashi, Hitoshi; Wijayanto, Titis; Lee, Joo-Young; Hashiguchi, Nobuko; Saat, Mohamed; Tochihara, Yutaka

    2014-02-04

    This study investigated the effect of hydration differences on body fluid and temperature regulation between tropical and temperate indigenes exercising in the heat. Ten Japanese and ten Malaysian males with matched physical characteristics (height, body weight, and peak oxygen consumption) participated in this study. Participants performed exercise for 60 min at 55% peak oxygen uptake followed by a 30-min recovery at 32°C and 70% relative air humidity with hydration (4 times each, 3 mL per kg body weight, 37°C) or without hydration. Rectal temperature, skin temperature, heart rate, skin blood flow, and blood pressure were measured continuously. The percentage of body weight loss and total sweat loss were calculated from body weight measurements. The percentage change in plasma volume was estimated from hemoglobin concentration and hematocrit. Malaysian participants had a significantly lower rectal temperature, a smaller reduction in plasma volume, and a lower heart rate in the hydrated condition than in the non-hydrated condition at the end of exercise (P <0.05), whereas Japanese participants showed no difference between the two hydration conditions. Hydration induced a greater total sweat loss in both groups (P <0.05), and the percentage of body weight loss in hydrated Malaysians was significantly less than in hydrated Japanese (P <0.05). A significant interaction between groups and hydration conditions was observed for the percentage of mean cutaneous vascular conductance during exercise relative to baseline (P <0.05). The smaller reduction in plasma volume and percentage body weight loss in hydrated Malaysians indicated an advantage in body fluid regulation. This may enable Malaysians to reserve more blood for circulation and heat dissipation and thereby maintain lower rectal temperatures in a hydrated condition.

  15. Alterations in Hormone Levels After Adjuvant Chemoradiation in Male Rectal Cancer Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yoon, Frederick H.; Perera, Francisco; Fisher, Barbara

    Purpose: To evaluate follicle-stimulating hormone (FSH), luteinizing hormone (LH), and testosterone levels after postoperative chemoradiation in men with rectal cancer. Methods and Materials: Forty-three men with rectal cancer had baseline and postchemoradiation FSH, LH, and testosterone measured. Adjuvant chemoradiation consisted of two 5-day cycles of bolus 5-fluorouracil (5-FU) every 4 weeks at a dose of 500 mg/m{sup 2}/d followed by concurrent chemoradiation followed by two additional 5-day cycles of 5-FU at a dose of 450 mg/m{sup 2}/d. Continuous-infusion 5-FU at 225 mg/m{sup 2}/d was given during radiation. Pelvic radiation consisted of a three- or four-field technique with a median dosemore » of 54.0 Gy in 30 fractions. Results: Median follow-up was 6.1 years. Mean baseline FSH levels increased from 5.3 to a peak of 23.9 IU/L (p < 0.001) 13-24 months after chemoradiation. Mean baseline LH levels increased from 4.3 to a peak of 8.5 IU/L (p < 0.001) within 6 months after chemoradiation. Mean testosterone levels decreased from 15.4 nmol/L at baseline to 8.0 nmol/L more than 4 years after chemoradiation. Mean testosterone to mean LH ratio decreased from 4.4 at baseline to 1.1 after 48 months posttreatment, suggesting a continued decrease in Leydig cell function with time. Testicular dose was measured in 5 patients. Median dose was 4 Gy (range, 1.5-8.9 Gy). Conclusions: Chemoradiation in men with rectal cancer causes persistent increases in FSH and LH levels and decreases in testosterone levels.« less

  16. [Effectiveness of Irinotecan, S-1, and Bevacizumab for Rectal Cancer with Lung and Skin Metastases after Adjuvant Chemotherapy].

    PubMed

    Hagihara, Kiyotaka; Ikeda, Masataka; Maeda, Sakae; Uemura, Mamoru; Yamamoto, Kazuyoshi; Miyake, Masakazu; Hama, Naoki; Nishikawa, Kazuhiro; Miyamoto, Atsushi; Omiya, Hideyasu; Miyazaki, Michihiko; Hirao, Motohiro; Takami, Koji; Nakamori, Shoji; Sekimoto, Mitsugu

    2016-11-01

    A 50-year-old woman with a chief complaint of bloody stools was diagnosed with rectal cancer via colonoscopy. Laparoscopic rectal anterior resection with D3 lymph node dissection was performed in June 2014. The pathological diagnosis was pStage III a(Ra, pT3, N1)cancer, and the patient received 8 courses of XELOX as postoperative adjuvant chemotherapy. During follow-up at 12 months after surgery, chest computed tomography revealed a mass in the left lingular segment measuring 25mm in diameter and multiple small nodules in both the lungs, indicating lung metastases. We found several subcutaneous nodules with a maximum diameter of 10mm in her abdomen and the back of head. We removed 3 subcutaneous nodules for the purpose of diagnosis and treatment in June of 2015. The pathological findings were consistent with cutaneous metastases of rectal cancer. The patient received a 1 course of IRIS and 5 courses of IRIS plus bevacizumab. Subsequently, the lung metastases disappeared and no new skin lesions were detected. We suggest that this case could be a good reference in determining the appropriate treatment for rectal cancer having lung or cutaneous metastases.

  17. Practice Patterns and Long-Term Survival for Early-Stage Rectal Cancer

    PubMed Central

    Stitzenberg, Karyn B.; Sanoff, Hanna K.; Penn, Dolly C.; Meyers, Michael O.; Tepper, Joel E.

    2013-01-01

    Purpose Standard of care treatment for most stage I rectal cancers is total mesorectal excision (TME). Given the morbidity associated with TME, local excision (LE) for early-stage rectal cancer has been explored. This study examines practice patterns and overall survival (OS) for early-stage rectal cancer. Methods All patients in the National Cancer Data Base diagnosed with rectal cancer from 1998 to 2010 were initially included. Use of LE versus proctectomy and use of adjuvant radiation therapy were compared over time. Adjusted Cox proportional hazards models were used to compare OS based on treatment. Results LE was used to treat 46.5% of patients with T1 and 16.8% with T2 tumors. Use of LE increased steadily over time (P < .001). LE was most commonly used for women, black patients, very old patients, those without private health insurance, those with well-differentiated tumors, and those with T1 tumors. Proctectomy was associated with higher rates of tumor-free surgical margins compared with LE (95% v 76%; P < .001). Adjuvant radiation therapy use decreased over time independent of surgical procedure or T stage. For T2N0 disease, patients treated with LE alone had significantly poorer adjusted OS than those treated with proctectomy alone or multimodality therapy. Conclusion Guideline-concordant adoption of LE for treatment of low-risk stage I rectal cancer is increasing. However, use of LE is also increasing for higher-risk rectal cancers that do not meet guideline criteria for LE. Treatment with LE alone is associated with poorer long-term OS. Additional studies are warranted to understand the factors driving increased use of LE. PMID:24166526

  18. Practice patterns and long-term survival for early-stage rectal cancer.

    PubMed

    Stitzenberg, Karyn B; Sanoff, Hanna K; Penn, Dolly C; Meyers, Michael O; Tepper, Joel E

    2013-12-01

    Standard of care treatment for most stage I rectal cancers is total mesorectal excision (TME). Given the morbidity associated with TME, local excision (LE) for early-stage rectal cancer has been explored. This study examines practice patterns and overall survival (OS) for early-stage rectal cancer. All patients in the National Cancer Data Base diagnosed with rectal cancer from 1998 to 2010 were initially included. Use of LE versus proctectomy and use of adjuvant radiation therapy were compared over time. Adjusted Cox proportional hazards models were used to compare OS based on treatment. LE was used to treat 46.5% of patients with T1 and 16.8% with T2 tumors. Use of LE increased steadily over time (P < .001). LE was most commonly used for women, black patients, very old patients, those without private health insurance, those with well-differentiated tumors, and those with T1 tumors. Proctectomy was associated with higher rates of tumor-free surgical margins compared with LE (95% v 76%; P < .001). Adjuvant radiation therapy use decreased over time independent of surgical procedure or T stage. For T2N0 disease, patients treated with LE alone had significantly poorer adjusted OS than those treated with proctectomy alone or multimodality therapy. Guideline-concordant adoption of LE for treatment of low-risk stage I rectal cancer is increasing. However, use of LE is also increasing for higher-risk rectal cancers that do not meet guideline criteria for LE. Treatment with LE alone is associated with poorer long-term OS. Additional studies are warranted to understand the factors driving increased use of LE.

  19. Random Forests to Predict Rectal Toxicity Following Prostate Cancer Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ospina, Juan D.; INSERM, U1099, Rennes; Escuela de Estadística, Universidad Nacional de Colombia Sede Medellín, Medellín

    2014-08-01

    Purpose: To propose a random forest normal tissue complication probability (RF-NTCP) model to predict late rectal toxicity following prostate cancer radiation therapy, and to compare its performance to that of classic NTCP models. Methods and Materials: Clinical data and dose-volume histograms (DVH) were collected from 261 patients who received 3-dimensional conformal radiation therapy for prostate cancer with at least 5 years of follow-up. The series was split 1000 times into training and validation cohorts. A RF was trained to predict the risk of 5-year overall rectal toxicity and bleeding. Parameters of the Lyman-Kutcher-Burman (LKB) model were identified and a logistic regression modelmore » was fit. The performance of all the models was assessed by computing the area under the receiving operating characteristic curve (AUC). Results: The 5-year grade ≥2 overall rectal toxicity and grade ≥1 and grade ≥2 rectal bleeding rates were 16%, 25%, and 10%, respectively. Predictive capabilities were obtained using the RF-NTCP model for all 3 toxicity endpoints, including both the training and validation cohorts. The age and use of anticoagulants were found to be predictors of rectal bleeding. The AUC for RF-NTCP ranged from 0.66 to 0.76, depending on the toxicity endpoint. The AUC values for the LKB-NTCP were statistically significantly inferior, ranging from 0.62 to 0.69. Conclusions: The RF-NTCP model may be a useful new tool in predicting late rectal toxicity, including variables other than DVH, and thus appears as a strong competitor to classic NTCP models.« less

  20. Measuring nanowire thermal conductivity at high temperatures

    NASA Astrophysics Data System (ADS)

    Wang, Xiaomeng; Yang, Juekuan; Xiong, Yucheng; Huang, Baoling; Xu, Terry T.; Li, Deyu; Xu, Dongyan

    2018-02-01

    This work extends the micro-thermal-bridge method for thermal conductivity measurements of nanowires to high temperatures. The thermal-bridge method, based on a microfabricated device with two side-by-side suspended membranes with integrated platinum resistance heaters/thermometers, has been used to determine thermal conductivity of various nanowires/nanotubes/nanoribbons at relatively low temperatures. However, to date, thermal conductivity characterization of nanowires at temperatures above 600 K has seldom been reported presumably due to several technical difficulties including the instability of the microfabricated thermometers, radiation heat loss, and the effect of the background conductance on the measurement. Here we report on our attempt to address the aforementioned challenges and demonstrate thermal conductivity measurement of boron nanoribbons up to 740 K. To eliminate high temperature resistance instability, the device is first annealed at 1023 K for 5 min in an argon atmosphere. Two radiation shields are installed in the measurement chamber to minimize radiation heat loss from the measurement device to the surroundings; and the temperature of the device at each set point is calibrated by an additional thermocouple directly mounted on the chip carrier. The effect of the background conductance is eliminated by adopting a differential measurement scheme. With all these modifications, we successfully measured the thermal conductivity of boron nanoribbons over a wide temperature range from 27 K to 740 K. The measured thermal conductivity increases monotonically with temperature and reaches a plateau of ~2.5 W m-1 K-1 at approximately 400 K, with no clear signature of Umklapp scattering observed in the whole measurement temperature range.

  1. Beneficial Effects of Early Enteral Nutrition After Major Rectal Surgery: A Possible Role for Conditionally Essential Amino Acids? Results of a Randomized Clinical Trial.

    PubMed

    van Barneveld, Kevin W Y; Smeets, Boudewijn J J; Heesakkers, Fanny F B M; Bosmans, Joanna W A M; Luyer, Misha D; Wasowicz, Dareczka; Bakker, Jaap A; Roos, Arnout N; Rutten, Harm J T; Bouvy, Nicole D; Boelens, Petra G

    2016-06-01

    To investigate direct postoperative outcome and plasma amino acid concentrations in a study comparing early enteral nutrition versus early parenteral nutrition after major rectal surgery. Previously, it was shown that a low plasma glutamine concentration represents poor prognosis in ICU patients. A preplanned substudy of a previous prospective, randomized, open-label, single-centre study, comparing early enteral nutrition versus early parenteral nutrition in patients at high risk of postoperative ileus after surgery for locally advanced or locally recurrent rectal cancer. Early enteral nutrition reduced postoperative ileus, anastomotic leakage, and hospital stay. Tertiary referral centre for locally advanced and recurrent rectal cancer. A total of 123 patients with locally advanced or recurrent rectal carcinoma requiring major rectal surgery. Patients were randomized (ALEA web-based external randomization) preoperatively into two groups: early enteral nutrition (early enteral nutrition, intervention) by nasojejunal tube (n = 61) or early parenteral nutrition (early parenteral nutrition, control) by jugular vein catheter (n = 62). Eight hours after the surgical procedure artificial nutrition was started in hemodynamically stable patients, stimulating oral intake in both groups. Blood samples were collected to measure plasma glutamine, citrulline, and arginine concentrations using a validated ultra performance liquid chromatography-tandem mass spectrometric method. Baseline concentrations were comparable for both groups. Directly after rectal surgery, a decrease in plasma amino acids was observed. Plasma glutamine concentrations were higher in the parenteral group than in the enteral group on postoperative day 1 (p = 0.027) and day 5 (p = 0.008). Arginine concentrations were also significantly increased in the parenteral group at day 1 (p < 0.001) and day 5 (p = 0.001). Lower plasma glutamine and arginine concentrations were measured in the enteral group, whereas a

  2. Endoscopic Submucosal Dissection of Rectal Cancer Close to the Dentate Line Accompanied by Mucosal Prolapse Syndrome

    PubMed Central

    Nakamura, Kenji; Ishii, Naoki; Suzuki, Koyu; Fukuda, Katsuyuki

    2018-01-01

    A 37-year-old man presented to our hospital for early rectal cancer accompanied by mucosal prolapse syndrome. Biopsy confirmed an adenocarcinoma, and endoscopic ultrasonography indicated proximity to the dentate line but no submucosal invasion. The tumor was removed en bloc via endoscopic submucosal dissection without complications, and its margin was free of tumor cells. The total procedure duration was 37 minutes, and the resected specimen measured 23 × 13 mm. There was no recurrence during the 3-year observation period. Although close to the dentate line and accompanied by mucosal prolapse syndrome, a rectal cancer lesion was safely resected en bloc using endoscopic submucosal dissection. PMID:29430468

  3. Rectal administration of metronidazole in severely ill patients.

    PubMed Central

    Barker, E M; Aitchison, J M; Cridland, J S; Baker, L W

    1983-01-01

    Ten severely ill patients with life threatening sepsis received metronidazole as suppositories and blood concentrations of the drug were measured twice daily over five days. Therapeutic blood concentrations of metronidazole were maintained at all times in all patients. Rectal administration of metronidazole is accepted as effective prophylaxis against infection associated with surgery and as treatment of established infection. This study shows that in gravely ill patients metronidazole administered as suppositories gives perfectly adequate therapeutic serum concentrations of the drug, but that to achieve these concentrations rapidly the first suppository should be given with an intravenous loading dose. PMID:6409287

  4. Renaissance of contact x-ray therapy for treating rectal cancer.

    PubMed

    Gérard, Jean-Pierre; Myint, Arthur Sun; Croce, Olivier; Lindegaard, Jacob; Jensen, Anie; Myerson, Robert; Hannoun-Lévi, Jean-Michel; Marcie, Serge

    2011-07-01

    Contact x-ray therapy (CXRT) with 50 kV has proven to be an efficient radiation therapy technique to achieve local control and rectal preservation for early rectal adenocarcinoma. Despite these results, CXRT has not been used due to the shortage of the no longer manufactured Philips RT 50™ unit. Recently, a new CXRT machine (Papillon 50™) became available on the market. This machine delivers a beam of 50 kV with a dose rate close to 15 Gy/min and has a percentage depth dose of 50% at 6-7 mm. The applicator size varies from 2-3 cm in diameter. Due to the original design of the main tube, treatment delivery is quick and more comfortable for the patients. An online viewing system incorporated in the tube allows a good visualization of the tumor with improved accuracy of radiation delivery. An international collaborative trial (Contact Endoscopic Microsurgery [CONTEM]) was set up to accrue approximately 300 cases of rectal adenocarcinoma staged T1, T2 or early T3 tumors in the UK, France, Denmark and Sweden. This trial should confirm the role of CXRT in curative treatment with organ preservation for early rectal cancers.

  5. Comparison of the oral and rectal mucosal and colonic serosal microcirculations of healthy, anesthetized horses.

    PubMed

    Kieffer, Philip J; Williams, Jarred M; Shepard, Molly K; Giguère, Steeve; Epstein, Kira L

    2018-01-01

    The objectives of the study were to: i) determine baseline microvascular perfusion indices (MPI) and assess their repeatability in healthy horses under general anesthesia, and ii) compare the MPIs of 3 microvascular beds (oral mucosa, colonic serosa, and rectal mucosa). Healthy adult horses were anesthetized and sidestream dark field microscopy was used to collect video loops of the oral mucosa, rectal mucosa, and colonic serosa under normotensive conditions without cardiovascular support drugs; videos were later analyzed to produce MPIs. Baseline MPI values were determined for each site, which included the total vessel density (TVD), perfused vessel density (PVD), portion perfused vessels (PPV), and microcirculatory flow index (MFI). Differences in MPIs between microvascular beds were not statistically significant. Repeatability of the measurements varied for each MPI. In particular, the site of sampling had a profound effect on the repeatability of the PPV measurements and should be considered in future studies.

  6. Comparison of the oral and rectal mucosal and colonic serosal microcirculations of healthy, anesthetized horses

    PubMed Central

    Kieffer, Philip J.; Williams, Jarred M.; Shepard, Molly K.; Giguère, Steeve; Epstein, Kira L.

    2018-01-01

    The objectives of the study were to: i) determine baseline microvascular perfusion indices (MPI) and assess their repeatability in healthy horses under general anesthesia, and ii) compare the MPIs of 3 microvascular beds (oral mucosa, colonic serosa, and rectal mucosa). Healthy adult horses were anesthetized and sidestream dark field microscopy was used to collect video loops of the oral mucosa, rectal mucosa, and colonic serosa under normotensive conditions without cardiovascular support drugs; videos were later analyzed to produce MPIs. Baseline MPI values were determined for each site, which included the total vessel density (TVD), perfused vessel density (PVD), portion perfused vessels (PPV), and microcirculatory flow index (MFI). Differences in MPIs between microvascular beds were not statistically significant. Repeatability of the measurements varied for each MPI. In particular, the site of sampling had a profound effect on the repeatability of the PPV measurements and should be considered in future studies. PMID:29382969

  7. An in vivo investigative protocol for HDR prostate brachytherapy using urethral and rectal thermoluminescence dosimetry.

    PubMed

    Toye, Warren; Das, Ram; Kron, Tomas; Franich, Rick; Johnston, Peter; Duchesne, Gillian

    2009-05-01

    To develop an in vivo dosimetry based investigative action level relevant for a corrective protocol for HDR brachytherapy boost treatment. The dose delivered to points within the urethra and rectum was measured using TLD in vivo dosimetry in 56 patients. Comparisons between the urethral and rectal measurements and TPS calculations showed differences, which are related to the relative position of the implant and TLD trains, and allowed shifts of implant position relative to the prostate to be estimated. Analysis of rectal dose measurements is consistent with implant movement, which was previously only identified with the urethral data. Shift corrected doses were compared with results from the TPS. Comparison of peak doses to the urethra and rectum has been assessed against the proposed corrective protocol to limit overdosing these critical structures. An initial investigative level of 20% difference between measured and TPS peak dose was established, which corresponds to 1/3 of patients which was practical for the caseload. These patients were assessed resulting in corrective action being applied for one patient. Multiple triggering for selective investigative action is outlined. The use of a single in vivo measurement in the first fraction optimizes patient benefit at acceptable cost.

  8. Modeling late rectal toxicities based on a parameterized representation of the 3D dose distribution

    NASA Astrophysics Data System (ADS)

    Buettner, Florian; Gulliford, Sarah L.; Webb, Steve; Partridge, Mike

    2011-04-01

    Many models exist for predicting toxicities based on dose-volume histograms (DVHs) or dose-surface histograms (DSHs). This approach has several drawbacks as firstly the reduction of the dose distribution to a histogram results in the loss of spatial information and secondly the bins of the histograms are highly correlated with each other. Furthermore, some of the complex nonlinear models proposed in the past lack a direct physical interpretation and the ability to predict probabilities rather than binary outcomes. We propose a parameterized representation of the 3D distribution of the dose to the rectal wall which explicitly includes geometrical information in the form of the eccentricity of the dose distribution as well as its lateral and longitudinal extent. We use a nonlinear kernel-based probabilistic model to predict late rectal toxicity based on the parameterized dose distribution and assessed its predictive power using data from the MRC RT01 trial (ISCTRN 47772397). The endpoints under consideration were rectal bleeding, loose stools, and a global toxicity score. We extract simple rules identifying 3D dose patterns related to a specifically low risk of complication. Normal tissue complication probability (NTCP) models based on parameterized representations of geometrical and volumetric measures resulted in areas under the curve (AUCs) of 0.66, 0.63 and 0.67 for predicting rectal bleeding, loose stools and global toxicity, respectively. In comparison, NTCP models based on standard DVHs performed worse and resulted in AUCs of 0.59 for all three endpoints. In conclusion, we have presented low-dimensional, interpretable and nonlinear NTCP models based on the parameterized representation of the dose to the rectal wall. These models had a higher predictive power than models based on standard DVHs and their low dimensionality allowed for the identification of 3D dose patterns related to a low risk of complication.

  9. Acoustical Measurement Of Furnace Temperatures

    NASA Technical Reports Server (NTRS)

    Parthasarathy, Shakkottai; Venkateshan, Shakkottai P.

    1989-01-01

    Simple probes withstand severe conditions, yet give spatially-resolved temperature readings. Prototype acoustical system developed to measure temperatures from ambient to 1,800 degree F in such structures as large industrial lime kilns and recovery-boiler furnaces. Pulses of sound reflected from obstructions in sensing tube. Speed of sound and temperature in each segment deduced from travel times of pulses.

  10. Does robotics improve minimally invasive rectal surgery? Functional and oncological implications.

    PubMed

    Guerra, Francesco; Pesi, Benedetta; Amore Bonapasta, Stefano; Perna, Federico; Di Marino, Michele; Annecchiarico, Mario; Coratti, Andrea

    2016-02-01

    Robot-assisted surgery has been reported to be a safe and effective alternative to conventional laparoscopy for the treatment of rectal cancer in a minimally invasive manner. Nevertheless, substantial data concerning functional outcomes and long-term oncological adequacy is still lacking. We aimed to assess the current role of robotics in rectal surgery focusing on patients' functional and oncological outcomes. A comprehensive review was conducted to search articles published in English up to 11 September 2015 concerning functional and/or oncological outcomes of patients who received robot-assisted rectal surgery. All relevant papers were evaluated on functional implications such as postoperative sexual and urinary dysfunction and oncological outcomes. Robotics showed a general trend towards lower rates of sexual and urinary postoperative dysfunction and earlier recovery compared with laparoscopy. The rates of 3-year local recurrence, disease-free survival and overall survival of robotic-assisted rectal surgery compared favourably with those of laparoscopy. This study fails to provide solid evidence to draw definitive conclusions on whether robotic systems could be useful in ameliorating the outcomes of minimally invasive surgery for rectal cancer. However, the available data suggest potential advantages over conventional laparoscopy with reference to functional outcomes. © 2016 Chinese Medical Association Shanghai Branch, Chinese Society of Gastroenterology, Renji Hospital Affiliated to Shanghai Jiaotong University School of Medicine and John Wiley & Sons Australia, Ltd.

  11. Age-related guideline adherence and outcome in low rectal cancer.

    PubMed

    Schiphorst, Anandi H W; Verweij, Norbert M; Pronk, Apollo; Hamaker, Marije E

    2014-08-01

    Care for elderly patients with low rectal cancer can pose dilemmas, because radical total mesorectal excision surgery comes with high morbidity and mortality rates. The purpose of this study was to analyze the treatment of patients with low rectal cancer, comparing treatment choices, guideline adherence, and outcomes for elderly patients (≥75 years) with younger patients (<75 years). Patient data were retrieved from the hospital pathology database and from the hospital prospective colorectal surgery database for surgically treated patients. Records were reviewed for nonadherence to treatment guidelines. Delivered treatment modalities for patients with stage I to III rectal cancer were compared with treatment advised by national guidelines, and reasons stated by the treating physician for nonadherence to guidelines were subsequently collected. This study was performed at a high-volume teaching hospital. Patients included were those with newly diagnosed rectal cancer (≤10 cm from the anal verge). Treatment decisions, guideline adherence, and outcome of surgical treatment were the main outcome parameters. Of 218 included patients, 75 (34%) were aged ≥75 years. Guideline adherence for all of the treatment modalities in stage I to III rectal cancer was significantly lower in elderly patients (62% versus 87% for aged <75 years; p < 0.001), and age was the primary reason mentioned for withholding treatment. Palliative anticancer treatment for stage IV disease was also initiated significantly less frequently in elderly patients (60% versus 97%; p = 0.002). Overall rates of treatment complications were similar for both patient groups (p = 0.71), but the impact of complications on survival was much greater for elderly patients (p = 0.002). Data on outcome of other treatment modalities, such as chemotherapy and radiotherapy, are lacking. Guideline adherence for all of the treatment modalities in stage I to III rectal cancer declines significantly with increasing age

  12. Low Rectal Cancer Study (MERCURY II)

    ClinicalTrials.gov

    2016-03-11

    Adenocarcinoma; Adenocarcinoma, Mucinous; Carcinoma; Neoplasms, Glandular and Epithelial; Neoplasms by Histologic Type; Neoplasms; Neoplasms, Cystic, Mucinous, and Serous; Colorectal Neoplasms; Intestinal Neoplasms; Gastrointestinal Neoplasms; Digestive System Neoplasms; Neoplasms by Site; Digestive System Diseases; Gastrointestinal Diseases; Intestinal Diseases; Rectal Diseases

  13. Spectroscopic temperature measurements in interior ballistic environments

    NASA Astrophysics Data System (ADS)

    Klingenberg, G.; Mach, H.

    1984-11-01

    Spectroscopic temperature measurements during the interior ballistic cycle of a 20 mm test fixture gun and inside the muzzle flash of a 7.62 mm rifle are described. The investigation yields information on temperature distribution in the burning propellant charge of the 20 mm test fixture and on radial temperature profiles in the 7.62 mm muzzle flash region. A technique to obtain temperature during the ignition and combustion within the 20 mm propellant charge is presented. Additional in-bore measurements by quartz windows mounted into bores along the barrel and emission-absorption measurements inside the muzzle flash of the 20 mm test fixture yield a complete temperature profile for the gun system. Spectroscopic infrared measurements inside the muzzle flash of a 7.62 mm rifle complete the investigation.

  14. Impact of rectal gonorrhoea and chlamydia on HIV viral load in the rectum: potential significance for onward transmission.

    PubMed

    Davies, Olubanke; Costelloe, Sinead; Cross, Gemma; Dew, Tracy; O'Shea, Siobhan; White, John; Fox, Julie

    2017-09-01

    The aim of this study was to investigate the effect of asymptomatic rectal bacterial sexually transmitted infections (STIs) on rectal HIV viral load (VL). A prospective cohort study of HIV-positive men who have sex with men attending a tertiary centre in London, UK, for their routine HIV care was performed. Forty-two HIV-positive men who have sex with men were recruited between January and August 2014. In participants on antiretroviral therapy (ART), there was no significant difference in rectal VL in those with and without STI ( p = 0.4). All rectal HIV VLs were below the limit of detection (<100 copies/µg of total RNA) whether an STI was present or not. In those not on ART, rectal HIV VL was on average 0.6log 10 lower post STI treatment. The presence of asymptomatic rectal chlamydia and gonorrhoea was not associated with increased rectal HIV VL in those fully suppressed on ART. In the context of effective ART, the presence of rectal gonorrhoea or chlamydia does not appear to increase rectal HIV VL and the risk of increased viral infectivity.

  15. Digital Rectal Examination Reduces Hospital Admissions, Endoscopies, and Medical Therapy in Patients with Acute Gastrointestinal Bleeding.

    PubMed

    Shrestha, Manish P; Borgstrom, Mark; Trowers, Eugene

    2017-07-01

    Although digital rectal examination is an established part of physical examinations in patients with acute gastrointestinal bleeding, clinicians are reluctant to perform a rectal examination. We intended to assess whether rectal examination affects the clinical management decision in these patients. We performed a single-center, retrospective, cross-sectional study using data from electronic health records of patients aged ≥18 years presenting to the emergency department with acute gastrointestinal bleeding. Hospital admissions, intensive care unit admissions, gastroenterology consultation, initiation of medical therapy (proton pump inhibitor or octreotide), and inpatient endoscopy (upper endoscopy or colonoscopy) were assessed as outcomes. Univariate and multivariate logistic regression analyses were performed. Of 1237 patients with acute gastrointestinal bleeding, 549 (44.4%) did not have a rectal examination. Patients who had a rectal examination were less likely to be admitted than patients who did not have a rectal examination (adjusted odds ratio [AOR], 0.49; 95% confidence interval [CI], 0.30-0.79; P = .004). Patients who had a rectal examination were less likely to be started on medical therapy (AOR, 0.64; 95% CI, 0.41-0.98; P = .04) and to have endoscopy (AOR, 0.64; 95% CI, 0.44-0.94; P = .02) than patients who did not have a rectal examination. Rectal examination in patients with acute gastrointestinal bleeding can assist clinicians with clinical management decision and reduce admissions, endoscopies, and medical therapy in these patients. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. The rabbit as an experimental model for biopharmaceutical studies following rectal administration of theophylline.

    PubMed

    Van Aerde, P; Moerman, E; Van Severen, R; Braeckman, P

    1984-03-01

    In order to find a suitable animal model for biopharmaceutical studies after rectal application of theophylline, the pharmacokinetics of theophylline following the administration in rabbits of three different rectal preparations were examined and compared with those of the oral and i. v. route. No significant formulation related impact from the studied rectal dosage forms on the bioavailability of the drug was found. However, the unexpected rapid achievement of peak serum concentration after insertion of the suppository lacked any correlation with human experiments. It was concluded that the evaluation of rectal theophylline medication for man cannot directly be based on the data obtained from rabbits.

  17. Rectal temperature responses of donkeys administered with ascorbic acid and subjected to load carrying (packing) during the harmattan season in Nigeria.

    PubMed

    Olaifa, Folashade; Ayo, Joseph Olusegun; Ambali, Suleiman Folorunsho; Rekwot, Peter Ibrahim; Minka, Ndazo Salka

    2013-02-01

    The aim of the experiment was to evaluate the effect of 4-h load carrying (packing) on donkeys administered with ascorbic acid (AA) during the harmattan season. Six donkeys administered orally with ascorbic acid (200 mg/kg) and subjected to packing served as experimental animals, while six others given only distilled water served as control animals. The rectal temperature (RT) of each donkey and dry-bulb temperature (DBT) and relative humidity (RH) of the research pen were recorded at 0600 hours pre-packing; while post-packing, the values were obtained at 1430, 1600 and 1800 hours. The DBT values (ranges) recorded before, during and after packing were 13.7 ± 1.3 °C (11-15 °C), 28.4 ± 1.0 °C (22.7-30.3 °C) and 30.6 ± 3.0 °C (19.8-45 °C), respectively. The highest temperature-humidity index (THI) of 83.4 ± 6.9 was obtained at 1430 hours after packing, and the value decreased to 64.2 ± 5.8 at 1800 hours. The thermal environmental conditions were outside the thermoneutral zone for the donkeys. The RT values recorded immediately after packing did not differ (P > 0.05) in experimental and control donkeys; but at 1600 and 1800 hours, values obtained in control donkeys (38.48 ± 0.12 and 38.12 ± 0.12 °C, respectively) were significantly higher (P < 0.05) than those recorded in experimental donkeys (38.16 ± 0.14 and 37.85 ± 0.14 °C, respectively). In conclusion, administration of ascorbic acid reduced the rise in RT due to packing and may be of value in the amelioration of adverse effects of heat stress associated with work in donkeys.

  18. 121. Man with temperature probe aimed at armature measuring temperature ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    121. Man with temperature probe aimed at armature measuring temperature as armature heats up between the two electrodes. March 27, 1985 - Statue of Liberty, Liberty Island, Manhattan, New York County, NY

  19. Pharmacokinetics of tramadol and its major metabolites following rectal and intravenous administration in dogs.

    PubMed

    Giorgi, M; Del Carlo, S; Saccomanni, G; Łebkowska-Wieruszewska, B; Kowalski, C J

    2009-06-01

    To compare the rectal and I/V administration of tramadol in dogs, to assess both its pharmacokinetic properties and absolute bioavailability. After rectal administration via suppositories and I/V injection of tramadol (4 mg/kg), the concentration of tramadol and its main metabolites, O-desmethyl-tramadol (M1), N-desmethyl-tramadol (M2) and N,O-didesmethyl-tramadol (M5), were determined in plasma, using high-performance liquid chromatography (HPLC). A balanced cross-over study was used, involving six male Beagle dogs. Plasma concentrations after rectal and I/V administration were fitted on the basis of mono- and bi-compartmental models, respectively. Following rectal administration tramadol was detected from 5 minutes up to 10 hours, in lesser amounts than M5 and M2, while M1 was detected in negligible amounts. Following I/V administration tramadol was detected up to 10 hours, M2 and M5 were detected at similar concentrations, and M1 was present at low concentrations. The area under the curve (AUC) of the three metabolites did not differ significantly after either route of administration of tramadol. The absolute bioavailability of tramadol via rectal administration was 10 (SD 4)%. After rectal administration of tramadol suppositories, absorption of the active ingredient was rapid, but its metabolism quickly transformed the parent drug to high levels of M2 and M5. In the dog, rectal pharmaceutical formulation of tramadol would have a different pharmacokinetic behaviour than in humans.

  20. Examining the Quality of Rectal Cancer Operative Reports in Teaching Institutions: Is There an Opportunity for Resident Education?

    PubMed

    Parrish, Aaron B; Sanaiha, Yas; Petrie, Beverley A; Russell, Marcia M; Chen, Formosa

    2016-10-01

    The American Society of Colon and Rectal Surgeons rectal cancer checklist describes a set of best practices for rectal cancer surgery. The objective of this study was to assess the quality of operative reports for rectal cancer surgery based on the intraoperative American Society of Colon and Rectal Surgeons checklist items. Patients undergoing rectal cancer surgery at two public teaching hospitals from 2009 to 2015 were included. A total of 12 intraoperative checklist items were assessed. One hundred and fifty-eight operative reports were reviewed. Overall adherence to checklist items was 55 per cent, and was significantly higher in attending versus resident dictated reports (67% vs 51%, P < 0.01). Senior residents had significantly higher adherence to checklist items than junior residents (55% vs 44%, P < 0.01). However, overall adherence to rectal cancer checklist items was low. This represents an opportunity to improve the quality of operative documentation in rectal cancer surgery, which could also impact the technical quality of the operation itself.

  1. Pharmacokinetics of rectal drug administration, Part I. General considerations and clinical applications of centrally acting drugs.

    PubMed

    van Hoogdalem, E; de Boer, A G; Breimer, D D

    1991-07-01

    Generally, oral administration is the route of choice in the daily practice of pharmacotherapy. However, in some circumstances this is impractical or even impossible (during nausea and vomiting or convulsions, in uncooperative patients and before surgery). In these cases, the rectal route may represent a practical alternative and rectal administration is now well accepted for delivering, for example, anticonvulsants, non-narcotic and narcotic analgesics, theophylline, antiemetics and antibacterial agents, and for inducing anaesthesia in children. It may also represent an interesting alternative to intravenous or other injection routes of drug administration. The rate and extent of rectal drug absorption are often lower than with oral absorption, possibly an inherent factor owing to the relatively small surface area available for drug uptake. In addition, the composition of the rectal formulation (solid vs liquid, nature of the suppository base) appears to be an important factor in the absorption process by determining the pattern of drug release. This relation between formulation and drug uptake has been clearly demonstrated for drugs like diazepam, paracetamol (acetaminophen), indomethacin, methadone and diflunisal. Coadministration of absorption-promoting agents (surfactants, sodium salicylate, enamines) represents another approach towards manipulating rectal drug absorption, although this concept requires further research concerning both efficacy and safety. For a number of drugs the extent of rectal absorption has been reported to exceed oral values, which may reflect partial avoidance of hepatic first-pass metabolism after rectal delivery. This phenomenon has been reported for morphine, metoclopramide, ergotamine, lidocaine (lignocaine) and propranolol. Rectal drug delivery in a site- and rate-controlled manner using osmotic pumps or hydrogel formulations may provide opportunities for manipulating systemic drug concentrations and drug effects. The extent of

  2. Azathioprine pharmacokinetics after intravenous, oral, delayed release oral and rectal foam administration.

    PubMed Central

    Van Os, E C; Zins, B J; Sandborn, W J; Mays, D C; Tremaine, W J; Mahoney, D W; Zinsmeister, A R; Lipsky, J J

    1996-01-01

    BACKGROUND: 6-Mercaptopurine and its prodrug azathioprine are effective medications for refractory inflammatory bowel disease. However, use of these drugs has been limited by concerns about their toxicity. Colonic delivery of azathioprine may reduce its systemic bioavailability and limit toxicity. AIM: To determine the bioavailability of 6-mercaptopurine after administration of azathioprine via three colonic delivery formulations. METHODS: Twenty four healthy human subjects each received 50 mg of azathioprine by one of four delivery formulations (each n = 6): oral; delayed release oral; hydrophobic rectal foam; and hydrophilic rectal foam. All subjects also received a 50 mg dose of intravenous azathioprine during a separate study period. Plasma concentrations of 6-mercaptopurine were determined by high pressure liquid chromatography. RESULTS: The bioavailabilities of 6-mercaptopurine after colonic azathioprine administration via delayed release oral, hydrophobic rectal foam, and hydrophilic rectal foam (7%, 5%, 1%; respectively) were significantly lower than the bioavailability of 6-mercaptopurine after oral azathioprine administration (47%) by Wilcoxon rank sum pairwise comparison. CONCLUSIONS: Azathioprine delivered to the colon by delayed release oral and rectal foam formulations considerably reduced systemic 6-mercaptopurine bioavailability. The therapeutic potential of these colonic delivery methods, which can potentially limit toxicity by local delivery of high doses of azathioprine, should be investigated in patients with inflammatory bowel disease. PMID:8881811

  3. Temporary Rectal Stenting for Management of Severe Perineal Wounds in Two Dogs.

    PubMed

    Skinner, Owen T; Cuddy, Laura C; Coisman, James G; Covey, Jennifer L; Ellison, Gary W

    Perineal wounds in dogs present a challenge due to limited local availability of skin for closure and constant exposure to fecal contaminants. This report describes temporary rectal stenting in two dogs following severe perineal wounds. Dog 1 presented with a 4 × 4 cm full-thickness perineal slough secondary to multiple rectal perforations. A 12 mm internal diameter endotracheal tube was placed per-rectum as a temporary stent to minimize fecal contamination. The stent was removed 18 days after placement, and the perineal wound had healed at 32 days post-stent placement, when a minor rectal stricture associated with mild, intermittent tenesmus was detected. Long-term outcome was deemed good. Dog 2 presented with multiple necrotic wounds with myiasis, circumferentially surrounding the anus and extending along the tail. A 14 mm internal diameter endotracheal tube was placed per-rectum. The perineal and tail wounds were managed with surgical debridement and wet-to-dry and honey dressings prior to caudectomy and negative pressure wound therapy (NPWT). Delayed secondary wound closure and stent removal were performed on day six without complication. Long-term outcome was deemed excellent. Temporary rectal stenting may be a useful technique for fecal diversion to facilitate resolution of complex perineal injuries, including rectal perforation.

  4. Design of a rectal probe for diffuse optical spectroscopy imaging for chemotherapy and radiotherapy monitoring

    NASA Astrophysics Data System (ADS)

    van de Giessen, Martijn; Santoro, Ylenia; Mirzaei Zarandi, Soroush; Pigazzi, Alessio; Cerussi, Albert E.; Tromberg, Bruce J.

    2014-03-01

    Diffuse optical spectroscopy imaging (DOSI) has shown great potential for the early detection of non-responding tumors during neoadjuvant chemotherapy in breast cancer, already one day after therapy starts. Patients with rectal cancer receive similar chemotherapy treatment. The rectum geometry and tissue properties of healthy and tumor tissue in the rectum and the requirement of surface contact impose constraints on the probe design. In this work we present the design of a DOSI probe with the aim of early chemotherapy/radiotherapy effectiveness detection in rectal tumors. We show using Monte Carlo simulations and phantom measurements that the colon tissue can be characterized reliably using a source-detector separation in the order of 10 mm. We present a design and rapid prototype of a probe for DOSI measurements that can be mounted on a standard laparoscope and that fits through a standard rectoscope. Using predominantly clinically approved components we aim at fast clinical translation.

  5. Relationship between body temperature, weight, and hematological parameters of black tufted-ear marmosets (Callithrix penicillata).

    PubMed

    Pereira, Lucas Cardoso; Barros, Marilia

    2016-06-01

    Basal thermal values of captive adult black tufted-ear marmosets (Callithrix penicillata) in a thermoneutral environment were measured via different methods, along with body weight and hematological parameters. Body temperatures were recorded with rectal (RC), subcutaneous (SC) microchip transponder and infrared (left and right) tympanic membrane (TM) thermometries. Thermal values were correlated with body mass and some hematological data. Similar RC and SC temperatures were observed, these being significantly higher than the left and right TM values. SC temperature was positively correlated and in close agreement with RC measurements. Although body temperatures were not influenced by gender, capture time, or body weight, they were correlated with hematological parameters. Thus, body temperatures in this species seem to reflect some of the characteristics of the assessments' location, with SC microchip transponders being a less invasive method to assess body temperature in these small-bodied non-human primates. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Compensation of Verdet Constant Temperature Dependence by Crystal Core Temperature Measurement

    PubMed Central

    Petricevic, Slobodan J.; Mihailovic, Pedja M.

    2016-01-01

    Compensation of the temperature dependence of the Verdet constant in a polarimetric extrinsic Faraday sensor is of major importance for applying the magneto-optical effect to AC current measurements and magnetic field sensing. This paper presents a method for compensating the temperature effect on the Faraday rotation in a Bi12GeO20 crystal by sensing its optical activity effect on the polarization of a light beam. The method measures the temperature of the same volume of crystal that effects the beam polarization in a magnetic field or current sensing process. This eliminates the effect of temperature difference found in other indirect temperature compensation methods, thus allowing more accurate temperature compensation for the temperature dependence of the Verdet constant. The method does not require additional changes to an existing Δ/Σ configuration and is thus applicable for improving the performance of existing sensing devices. PMID:27706043

  7. Method and apparatus for optical temperature measurement

    DOEpatents

    O'Rourke, P.E.; Livingston, R.R.; Prather, W.S.

    1994-09-20

    A temperature probe and a method for using said probe for temperature measurements based on changes in light absorption by the probe are disclosed. The probe comprises a first and a second optical fiber that carry light to and from the probe, and a temperature sensor material, the absorbance of which changes with temperature, through which the light is directed. Light is directed through the first optical fiber, passes through the temperature sensor material, and is transmitted by a second optical fiber from the material to a detector. Temperature-dependent and temperature-independent factors are derived from measurements of the transmitted light intensity. For each sensor material, the temperature T is a function of the ratio, R, of these factors. The temperature function f(R) is found by applying standard data analysis techniques to plots of T versus R at a series of known temperatures. For a sensor having a known temperature function f(R) and known characteristic and temperature-dependent factors, the temperature can be computed from a measurement of R. Suitable sensor materials include neodymium-doped borosilicate glass, accurate to [+-]0.5 C over an operating temperature range of about [minus]196 C to 400 C; and a mixture of D[sub 2]O and H[sub 2]O, accurate to [+-]0.1 C over an operating range of about 5 C to 90 C. 13 figs.

  8. Method and apparatus for optical temperature measurement

    DOEpatents

    O'Rourke, Patrick E.; Livingston, Ronald R.; Prather, William S.

    1994-01-01

    A temperature probe and a method for using said probe for temperature measurements based on changes in light absorption by the probe. The probe comprises a first and a second optical fiber that carry light to and from the probe, and a temperature sensor material, the absorbance of which changes with temperature, through which the light is directed. Light is directed through the first optical fiber, passes through the temperature sensor material, and is transmitted by a second optical fiber from the material to a detector. Temperature-dependent and temperature-independent factors are derived from measurements of the transmitted light intensity. For each sensor material, the temperature T is a function of the ratio, R, of these factors. The temperature function f(R) is found by applying standard data analysis techniques to plots of T versus R at a series of known temperatures. For a sensor having a known temperature function f(R) and known characteristic and temperature-dependent factors, the temperature can be computed from a measurement of R. Suitable sensor materials include neodymium-doped boresilicate glass, accurate to .+-.0.5.degree. C. over an operating temperature range of about -196.degree. C. to 400.degree. C.; and a mixture of D.sub.2 O and H.sub.2 O, accurate to .+-.0.1.degree. C. over an operating range of about 5.degree. C. to 90.degree. C.

  9. Temperature measurement method using temperature coefficient timing for resistive or capacitive sensors

    DOEpatents

    Britton, Jr., Charles L.; Ericson, M. Nance

    1999-01-01

    A method and apparatus for temperature measurement especially suited for low cost, low power, moderate accuracy implementation. It uses a sensor whose resistance varies in a known manner, either linearly or nonlinearly, with temperature, and produces a digital output which is proportional to the temperature of the sensor. The method is based on performing a zero-crossing time measurement of a step input signal that is double differentiated using two differentiators functioning as respective first and second time constants; one temperature stable, and the other varying with the sensor temperature.

  10. Temperature measurement method using temperature coefficient timing for resistive or capacitive sensors

    DOEpatents

    Britton, C.L. Jr.; Ericson, M.N.

    1999-01-19

    A method and apparatus for temperature measurement especially suited for low cost, low power, moderate accuracy implementation. It uses a sensor whose resistance varies in a known manner, either linearly or nonlinearly, with temperature, and produces a digital output which is proportional to the temperature of the sensor. The method is based on performing a zero-crossing time measurement of a step input signal that is double differentiated using two differentiators functioning as respective first and second time constants; one temperature stable, and the other varying with the sensor temperature. 5 figs.

  11. The curative management of synchronous rectal and prostate cancer

    PubMed Central

    Kavanagh, Dara O; Martin, Joseph; Small, Cormac; Joyce, Myles R; Faul, Clare M; Kelly, Paul J; O'Riordain, Michael; Gillham, Charles M; Armstrong, John G; Salib, Osama; McNamara, Deborah A; McVey, Gerard; O'Neill, Brian D P

    2016-01-01

    Objective: Neoadjuvant “long-course” chemoradiation is considered a standard of care in locally advanced rectal cancer. In addition to prostatectomy, external beam radiotherapy and brachytherapy with or without androgen suppression (AS) are well established in prostate cancer management. A retrospective review of ten cases was completed to explore the feasibility and safety of applying these standards in patients with dual pathology. To our knowledge, this is the largest case series of synchronous rectal and prostate cancers treated with curative intent. Methods: Eligible patients had synchronous histologically proven locally advanced rectal cancer (defined as cT3-4Nx; cTxN1-2) and non-metastatic prostate cancer (pelvic nodal disease permissible). Curative treatment was delivered to both sites simultaneously. Follow-up was as per institutional guidelines. Acute and late toxicities were reviewed, and a literature search performed. Results: Pelvic external beam radiotherapy (RT) 45–50.4 Gy was delivered concurrent with 5-fluorouracil (5FU). Prostate total dose ranged from 70.0 to 79.2 Gy. No acute toxicities occurred, excluding AS-induced erectile dysfunction. Nine patients proceeded to surgery, and one was managed expectantly. Three relapsed with metastatic colorectal cancer, two with metastatic prostate cancer. Five patients have no evidence of recurrence, and four remain alive with metastatic disease. With a median follow-up of 2.2 years (range 1.2–6.3 years), two significant late toxicities occurred; G3 proctitis in a patient receiving palliative bevacizumab and a G3 anastomotic stricture precluding stoma reversal. Conclusion: Patients proceeding to synchronous radical treatment of both primary sites should receive 45–50.4 Gy pelvic RT with infusional 5FU. Prostate dose escalation should be given with due consideration to the potential impact of prostate cancer on patient survival, as increasing dose may result in significant late morbidity

  12. 7 CFR 28.301 - Measurement: humidity; temperature.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Measurement: humidity; temperature. 28.301 Section 28... for Length of Staple § 28.301 Measurement: humidity; temperature. The length of staple of any cotton... its fibers under a relative humidity of the atmosphere of 65 percent and a temperature of 70 °F. ...

  13. 7 CFR 28.301 - Measurement: humidity; temperature.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Measurement: humidity; temperature. 28.301 Section 28... for Length of Staple § 28.301 Measurement: humidity; temperature. The length of staple of any cotton... its fibers under a relative humidity of the atmosphere of 65 percent and a temperature of 70 °F. ...

  14. 7 CFR 28.301 - Measurement: humidity; temperature.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Measurement: humidity; temperature. 28.301 Section 28... for Length of Staple § 28.301 Measurement: humidity; temperature. The length of staple of any cotton... its fibers under a relative humidity of the atmosphere of 65 percent and a temperature of 70° F. ...

  15. 7 CFR 28.301 - Measurement: humidity; temperature.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Measurement: humidity; temperature. 28.301 Section 28... for Length of Staple § 28.301 Measurement: humidity; temperature. The length of staple of any cotton... its fibers under a relative humidity of the atmosphere of 65 percent and a temperature of 70 °F. ...

  16. 7 CFR 28.301 - Measurement: humidity; temperature.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Measurement: humidity; temperature. 28.301 Section 28... for Length of Staple § 28.301 Measurement: humidity; temperature. The length of staple of any cotton... its fibers under a relative humidity of the atmosphere of 65 percent and a temperature of 70 °F. ...

  17. Reliability issues in human brain temperature measurement

    PubMed Central

    2009-01-01

    Introduction The influence of brain temperature on clinical outcome after severe brain trauma is currently poorly understood. When brain temperature is measured directly, different values between the inside and outside of the head can occur. It is not yet clear if these differences are 'real' or due to measurement error. Methods The aim of this study was to assess the performance and measurement uncertainty of body and brain temperature sensors currently in use in neurocritical care. Two organic fixed-point, ultra stable temperature sources were used as the temperature references. Two different types of brain sensor (brain type 1 and brain type 2) and one body type sensor were tested under rigorous laboratory conditions and at the bedside. Measurement uncertainty was calculated using internationally recognised methods. Results Average differences between the 26°C reference temperature source and the clinical temperature sensors were +0.11°C (brain type 1), +0.24°C (brain type 2) and -0.15°C (body type), respectively. For the 36°C temperature reference source, average differences between the reference source and clinical thermometers were -0.02°C, +0.09°C and -0.03°C for brain type 1, brain type 2 and body type sensor, respectively. Repeat calibrations the following day confirmed that these results were within the calculated uncertainties. The results of the immersion tests revealed that the reading of the body type sensor was sensitive to position, with differences in temperature of -0.5°C to -1.4°C observed on withdrawing the thermometer from the base of the isothermal environment by 4 cm and 8 cm, respectively. Taking into account all the factors tested during the calibration experiments, the measurement uncertainty of the clinical sensors against the (nominal) 26°C and 36°C temperature reference sources for the brain type 1, brain type 2 and body type sensors were ± 0.18°C, ± 0.10°C and ± 0.12°C respectively. Conclusions The results show that

  18. Real-time core body temperature estimation from heart rate for first responders wearing different levels of personal protective equipment.

    PubMed

    Buller, Mark J; Tharion, William J; Duhamel, Cynthia M; Yokota, Miyo

    2015-01-01

    First responders often wear personal protective equipment (PPE) for protection from on-the-job hazards. While PPE ensembles offer individuals protection, they limit one's ability to thermoregulate, and can place the wearer in danger of heat exhaustion and higher cardiac stress. Automatically monitoring thermal-work strain is one means to manage these risks, but measuring core body temperature (Tc) has proved problematic. An algorithm that estimates Tc from sequential measures of heart rate (HR) was compared to the observed Tc from 27 US soldiers participating in three different chemical/biological training events (45-90 min duration) while wearing PPE. Hotter participants (higher Tc) averaged (HRs) of 140 bpm and reached Tc around 39 °C. Overall the algorithm had a small bias (0.02 °C) and root mean square error (0.21 °C). Limits of agreement (LoA ± 0.48 °C) were similar to comparisons of Tc measured by oesophageal and rectal probes. The algorithm shows promise for use in real-time monitoring of encapsulated first responders. An algorithm to estimate core temperature (Tc) from non-invasive measures of HR was validated. Three independent studies (n = 27) compared the estimated Tc to the observed Tc in humans participating in chemical/ biological hazard training. The algorithm’s bias and variance to observed data were similar to that found from comparisons of oesophageal and rectal measurements.

  19. A New Surgical Device for Anterograde Intraoperative Rectal Washout.

    PubMed

    Rondelli, Fabio; Santinelli, Roberto; Stella, Paolo; Bugiantella, Walter; Ceccarelli, Graziano; Balzarotti, Ruben Carlo; De Rosa, Michele; Avenia, Nicola

    2018-06-01

    Colorectal cancer is the fourth most diffuse cause of death in the world and local recurrence is associated with a reduced long-term life expectancy, with a reduced quality of life. Rectal washout at the anastomosis site leads to a statistically significant reduction of local recurrences. We developed the idea of a new laparoscopic stapler with an integrated washout system that could decontaminate the rectal stump before resection, without the need to enlarge the standard surgical incision or even to distort the incision site, closing the rectal stump just below the inferior part of the cancer, and then proceeding with the resection and stapling of the distal part of the tumor. Combined with these canonical functionalities, the new device, equipped with a patented washout system (patent number EP 3103401A1) will also allow to inject in the closed bowel a physiologic saline liquid. In force of the mechanical action of the liquid injected, carcinogenic exfoliated cells eventually floating in the affected region of the colonic lumen will be expelled through the anal orifice. The intraoperative rectal washout, both in minimally invasive and in traditional open surgery, thus becomes a simple, effective, and reproducible procedure. We describe the technical features and the possible clinical applications of a potentially new surgical laparoscopic stapler coupled with an integrated irrigation system. We have patented the system and we are developing a prototype with the aim to start an experimental pilot study.

  20. MISSE 1 and 2 Tray Temperature Measurements

    NASA Technical Reports Server (NTRS)

    Harvey, Gale A.; Kinard, William H.

    2006-01-01

    The Materials International Space Station Experiment (MISSE 1 & 2) was deployed August 10,2001 and retrieved July 30,2005. This experiment is a co-operative endeavor by NASA-LaRC. NASA-GRC, NASA-MSFC, NASA-JSC, the Materials Laboratory at the Air Force Research Laboratory, and the Boeing Phantom Works. The objective of the experiment is to evaluate performance, stability, and long term survivability of materials and components planned for use by NASA and DOD on future LEO, synchronous orbit, and interplanetary space missions. Temperature is an important parameter in the evaluation of space environmental effects on materials. The MISSE 1 & 2 had autonomous temperature data loggers to measure the temperature of each of the four experiment trays. The MISSE tray-temperature data loggers have one external thermistor data channel, and a 12 bit digital converter. The MISSE experiment trays were exposed to the ISS space environment for nearly four times the nominal design lifetime for this experiment. Nevertheless, all of the data loggers provided useful temperature measurements of MISSE. The temperature measurement system has been discussed in a previous paper. This paper presents temperature measurements of MISSE payload experiment carriers (PECs) 1 and 2 experiment trays.

  1. Increasing trend in retained rectal foreign bodies

    PubMed Central

    Ayantunde, Abraham A; Unluer, Zynep

    2016-01-01

    AIM To highlight the rising trend in hospital presentation of foreign bodies retained in the rectum over a 5-year period. METHODS Retrospective review of the cases of retained rectal foreign bodies between 2008 and 2012 was performed. Patients’ clinical data and yearly case presentation with data relating to hospital episodes were collected. Data analysis was by SPSS Inc. Chicago, IL, United States. RESULTS Twenty-five patients presented over a 5-year period with a mean age of 39 (17-62) years and M: F ratio of 2:1. A progressive rise in cases was noted from 2008 to 2012 with 3, 4, 4, 6, 8 recorded patients per year respectively. The majority of the impacted rectal objects were used for self-/partner-eroticism. The commonest retained foreign bodies were sex vibrators and dildos. Ninty-six percent of the patients required extraction while one passed spontaneously. Two and three patients had retrieval in the Emergency Department and on the ward respectively while 19 patients needed examination under anaesthesia for extraction. The mean hospital stay was 19 (2-38) h. Associated psychosocial issues included depression, deliberate self-harm, illicit drug abuse, anxiety and alcoholism. There were no psychosocial problems identified in 15 patients. CONCLUSION There is a progressive rise in hospital presentation of impacted rectal foreign bodies with increasing use of different objects for sexual arousal. PMID:27830039

  2. Increasing trend in retained rectal foreign bodies.

    PubMed

    Ayantunde, Abraham A; Unluer, Zynep

    2016-10-27

    To highlight the rising trend in hospital presentation of foreign bodies retained in the rectum over a 5-year period. Retrospective review of the cases of retained rectal foreign bodies between 2008 and 2012 was performed. Patients' clinical data and yearly case presentation with data relating to hospital episodes were collected. Data analysis was by SPSS Inc. Chicago, IL, United States. Twenty-five patients presented over a 5-year period with a mean age of 39 (17-62) years and M: F ratio of 2:1. A progressive rise in cases was noted from 2008 to 2012 with 3, 4, 4, 6, 8 recorded patients per year respectively. The majority of the impacted rectal objects were used for self-/partner-eroticism. The commonest retained foreign bodies were sex vibrators and dildos. Ninty-six percent of the patients required extraction while one passed spontaneously. Two and three patients had retrieval in the Emergency Department and on the ward respectively while 19 patients needed examination under anaesthesia for extraction. The mean hospital stay was 19 (2-38) h. Associated psychosocial issues included depression, deliberate self-harm, illicit drug abuse, anxiety and alcoholism. There were no psychosocial problems identified in 15 patients. There is a progressive rise in hospital presentation of impacted rectal foreign bodies with increasing use of different objects for sexual arousal.

  3. Novel application of internal obturator and semitendinosus muscle flaps for rectal wall repair or reinforcement.

    PubMed

    Riggs, J; Ladlow, J F; Owen, L J; Hall, J L

    2018-01-29

    Internal obturator and/or semitendinosus muscle flaps were used to reinforce primary appositional rectal wall repair in three dogs and one cat in this case series. All three dogs incurred rectal wall compromise during surgical excision of anal sac tumours. The cat sustained bite wounds to the perianal region resulting in abscessation and a rectal tear. Our results indicate that application of an internal obturator and/or semitendinosus muscle flap can reduce the risk of rectal wall dehiscence after primary repair, and consequently the risk of pararectal abscess or rectocutaneous fistula formation. © 2018 British Small Animal Veterinary Association.

  4. Ultrastructure and ATPase activity of the rectal gland of the chondrichthyean fish Hydrolagus colliei (Holocephali).

    PubMed

    Lagios, M D; Stasko-Concannon, S

    1979-05-18

    The anatomy, histology, ultrastructure and ATPase activity of the intramural rectal gland of the chondrichthyean Hydrolagus colliei, are described. The cells of the rectal gland of Hydrolagus demonstrate the same well developed lateral and basal cisternae, elongate mitochondria and luminal border as those of their elasmobranch counterparts. ATPase activity within the rectal gland of Hydrolagus is as intense as that in a number of elasmobranchs examined in the course of the study. Despite its primitive intramural location the rectal gland of Hydrolagus represents a homolog of the more specialized and better known elasmobranch gland and appears as well suited for cation excretion.

  5. Laparoscopic treatment of rectal cancer and lateral pelvic lymph node dissection. Are they obsolete?

    PubMed

    Toda, Shigeo; Kuroyanagi, Hiroya; Matoba, Shuichiro; Hiramatsu, Kosuke; Okazaki, Naoto; Tate, Tomohiro; Tomizawa, Kenji; Hanaoka, Yutaka; Moriyama, Jin

    2018-05-24

    Laparoscopic surgery for rectal cancer offers favorable short term results without compromising long term oncological outcomes so far, according to the data from major trials. Therefore it is being considered as a standard option for rectal cancer surgery. The learning curve of laparoscopic rectal cancer surgery is generally longer compared to colon cancer. Appropriate standardization and training of laparoscopic rectal cancer surgery is required. Several RCTs suggested the potential negative effect on quality of resected specimen, which can increase local recurrence. The long term outcomes especially local recurrence rate of these RCTs are awaited. Lateral pelvic lymph node dissection (LPLND) has a certain effect of reducing local recurrence of rectal cancer even after neoadjuvant radiotherapy. Since LPLND is associated with postoperative morbidity, we should carefully select the candidate to maximize the effect of LPLND and minimize the morbidity caused by LPLND. Recent advancement in imaging study such as CT and MRI enables us to find the suitable candidates for LPLND. The morbidity caused by LPLND could be reduced by minimally invasive surgeries such as laparoscopic surgery and robotic surgery. We have to improve oncological outcomes and reduce morbidity by the multidisciplinary strategy for rectal cancer including total mesorectal excision, neoadjuvant chemoradiotherapy and LPLND together with laparoscopic surgery.

  6. Microstructure imaging of human rectal mucosa using multiphoton microscopy

    NASA Astrophysics Data System (ADS)

    Liu, N. R.; Chen, G.; Chen, J. X.; Yan, J.; Zhuo, S. M.; Zheng, L. Q.; Jiang, X. S.

    2011-01-01

    Multiphoton microscopy (MPM) has high resolution and sensitivity. In this study, MPM was used to image microstructure of human rectal mucosa. The morphology and distribution of the main components in mucosa layer, absorptive cells and goblet cells in the epithelium, abundant intestinal glands in the lamina propria and smooth muscle fibers in the muscularis mucosa were clearly monitored. The variations of these components were tightly relevant to the pathology in gastrointestine system, especially early rectal cancer. The obtained images will be helpful for the diagnosis of early colorectal cancer.

  7. The effects of heated and room-temperature abdominal lavage solutions on core body temperature in dogs undergoing celiotomy.

    PubMed

    Nawrocki, Michael A; McLaughlin, Ron; Hendrix, P K

    2005-01-01

    To document the magnitude of temperature elevation obtained with heated lavage solutions during abdominal lavage, 18 dogs were lavaged with sterile isotonic saline intraoperatively (i.e., during a celiotomy). In nine dogs, room-temperature saline was used. In the remaining nine dogs, saline heated to 43+/-2 degrees C (110+/-4 degrees F) was used. Esophageal, rectal, and tympanic temperatures were recorded every 60 seconds for 15 minutes after initiation of the lavage. Temperature levels decreased in dogs lavaged with room-temperature saline. Temperature levels increased significantly in dogs lavaged with heated saline after 2 to 6 minutes of lavage, and temperatures continued to increase throughout the 15-minute lavage period.

  8. Predictive Biomarkers of Radiation Sensitivity in Rectal Cancer

    NASA Astrophysics Data System (ADS)

    Tut, Thein Ga

    Colorectal cancer (CRC) is the third most common cancer in the world. Australia, New Zealand, Canada, the United States, and parts of Europe have the highest incidence rates of CRC. China, India, South America and parts of Africa have the lowest risk of CRC. CRC is the second most common cancer in both sexes in Australia. Even though the death rates from CRC involving the colon have diminished, those arising from the rectum have revealed no improvement. The greatest obstacle in attaining a complete surgical resection of large rectal cancers is the close anatomical relation to surrounding structures, as opposed to the free serosal surfaces enfolding the colon. To assist complete resection, pre-operative radiotherapy (DXT) can be applied, but the efficacy of ionising radiation (IR) is extremely variable between individual tumours. Reliable predictive marker/s that enable patient stratification in the application of this otherwise toxic therapy is still not available. Current therapeutic management of rectal cancer can be improved with the availability of better predictive and prognostic biomarkers. Proteins such as Plk1, gammaH2AX and MMR proteins (MSH2, MSH6, MLH1 and PMS2), involved in DNA damage response (DDR) pathway may be possible biomarkers for radiation response prediction and prognostication of rectal cancer. Serine/threonine protein kinase Plk1 is overexpressed in most of cancers including CRC. Plk1 functional activity is essential in the restoration of DNA damage following IR, which causes DNA double strand break (DSB). The earliest manifestation of this reparative process is histone H2AX phosphorylation at serine 139, leading to gammaH2AX. Colorectal normal mucosa showed the lowest level of gammaH2AX with gradually increasing levels in early adenoma and then in advanced malignant colorectal tissues, leading to the possibility that gammaH2AX may be a prospective biomarker in rectal cancer management. There are numerous publications regarding DNA mismatch

  9. Cardiopulmonary exercise testing for the prediction of morbidity risk after rectal cancer surgery.

    PubMed

    West, M A; Parry, M G; Lythgoe, D; Barben, C P; Kemp, G J; Grocott, M P W; Jack, S

    2014-08-01

    This study investigated the relationship between objectively measured physical fitness variables derived by cardiopulmonary exercise testing (CPET) and in-hospital morbidity after rectal cancer surgery. Patients scheduled for rectal cancer surgery underwent preoperative CPET (reported blind to patient characteristics) with recording of morbidity (recorded blind to CPET variables). Non-parametric receiver operating characteristic (ROC) curves and logistic regression were used to assess the relationship between CPET variables and postoperative morbidity. Of 105 patients assessed, 95 (72 men) were included; ten patients had no surgery and were excluded (3 by choice, 7 owing to unresectable metastasis). Sixty-eight patients had received neoadjuvant treatment. ROC curve analysis of oxygen uptake (V˙o2 ) at estimated lactate threshold (θ^L ) and peak V˙o2 gave an area under the ROC curve of 0·87 (95 per cent confidence interval 0·78 to 0·95; P < 0·001) and 0·85 (0·77 to 0·93; P < 0·001) respectively, indicating that they can help discriminate patients at risk of postoperative morbidity. The optimal cut-off points identified were 10·6 and 18·6 ml per kg per min for V˙o2 at θ^L and peak respectively. CPET can help predict morbidity after rectal cancer surgery. © 2014 BJS Society Ltd. Published by John Wiley & Sons Ltd.

  10. Head temperature modulates thermal behavior in the cold in humans

    PubMed Central

    Mündel, Toby; Raman, Aaron; Schlader, Zachary J.

    2016-01-01

    ABSTRACT We tested the hypothesis that skin temperature, specifically of the head, is capable of modulating thermal behavior during exercise in the cold. Following familiarization 8 young, healthy, recreationally active males completed 3 trials, each consisting of 30 minutes of self-paced cycle ergometry in 6°C. Participants were instructed to control their exercise work rate to achieve and maintain thermal comfort. On one occasion participants wore only shorts and shoes (Control) and on the 2 other occasions their head was either warmed (Warming) or cooled (Cooling). Work rate, rate of metabolic heat production, thermal perceptions, rectal, mean weighted skin and head temperatures were measured. Exercise work rate was reduced during Warming and augmented during Cooling after the first and second minutes of exercise, respectively (P ≤ 0.04), with the rate of metabolic heat production mirroring work rate. At this early stage of exercise (≤5 min) the changes over time for rectal temperature were negligible and similar (0.1 ± 0.1°C, P = 0.51), while the decrease in mean skin temperature was not different between all trials (1.7 ± 0.6°C, P = 0.13). Mean head temperature was either decreased (Control: 1.5 ± 1.1°C, Cooling: 2.9 ± 0.8°C, both P < 0.01) or increased (Warming: 1.7 ± 0.9°C, P < 0.01). Head thermal perception was warmer and more comfortable in Warming and cooler and less comfortable in Cooling (P < 0.01). Participants achieved thermal comfort similarly in all trials (P > 0.09) after 10 ± 7 min and this was maintained until the end of exercise. These results indicate that peripheral temperatures modulate thermal behavior in the cold. PMID:27857959

  11. Non-contact temperature measurement requirements

    NASA Technical Reports Server (NTRS)

    Higgins, D. B.; Witherow, W. K.

    1989-01-01

    The Marshall Space Flight Center is involved with levitation experiments for Spacelab, Space Station, and drop tube/tower operations. These experiments have temperature measurement requirements, that of course must be non-contact in nature. The experiment modules involved are the Acoustic Levitator Furnace (ALF), and the Modular Electromagnetic Levitator (MEL). User requirements of the ALF and drop tube are presented. The center also has temperature measurement needs that are not microgravity experiment oriented, but rather are related to the propulsion system for the STS. This requirement will also be discussed.

  12. Rectal Cancer in Asian vs. Western Countries: Why the Variation in Incidence?

    PubMed

    Deng, Yanhong

    2017-09-25

    Colorectal cancer (CRC) is the third most common cancer worldwide. CRC has been thought to be less common in Asia compared to Western countries. However, the incidence rates of CRC in Asia are high and there is an increasing trend in the Asian population. Furthermore, colorectal cancer accounts for the greatest number of all incidences of CRC in Asia. The increasing adoption of a Western lifestyle, particularly in dietary habits, is likely the most important factor contributing to the rapid increase in colon cancer incidence; it is noteworthy that trends for rectal cancer were flat. The etiology of colon and rectal cancer is a bit different. The risks of distal colon and rectal cancers are more likely to be related to environmental factors, such as polluted surface water sources, alcohol consumption, and habitual smoking. The lack of great change in the incidence of rectal cancer might be due to weaker associations with such lifestyle factors. Therefore, it has been hypothesized that proximal and distal sections of the colon and rectum are two different organs in terms of function and genetic background. It may mean differences in differential sensitivities and exposures to carcinogens. However, despite the decrease in whole incidence, the CRC incidence in young adults in Western countries are reversely increasing, especially in rectal cancer, due to reasons largely unknown. Although the treatment algorithm is different between Asia and western countries, globally, the survival rate for patients with rectal cancer has risen during the past 10 years. Screening contributes a great deal to reducing the incidence and improving survival. Most countries in Asia, such as China, need nationwide registration and screening systems to provide better data.

  13. Learning curve for robotic-assisted laparoscopic rectal cancer surgery.

    PubMed

    Jiménez-Rodríguez, Rosa M; Díaz-Pavón, José Manuel; de la Portilla de Juan, Fernando; Prendes-Sillero, Emilio; Dussort, Hisnard Cadet; Padillo, Javier

    2013-06-01

    One of the main uses of robotic assisted abdominal surgery is the mesorectal excision in patients with rectal cancer. The aim of the present study is to analyse the learning curve for robotic assisted laparoscopic resection of rectal cancer. We included in our study 43 consecutive rectal cancer resections (16 females and 27 males) performed from January 2008 through December 2010. Mean age of patients was 66 ± 9.0 years. Surgical procedures included both abdomino-perineal and anterior resections. We analysed the following parameters: demographic data of the patients included in the study, intra- and postoperative data, time taking to set up the robot for operations (set-up or docking time), operative time, intra- and postoperative complications, conversion rates and pathological specimen features. The learning curve was analysed using cumulative sum (CUSUM) methodology. The procedures understudied included seven abdomino-perineal resections and 36 anterior resections. In our series of patients, mean robotic set-up time was 62.9 ± 24.6 min, and the mean operative time was 197.4 ± 44.3 min. Once we applied CUSUM methodology, we obtained two graphs for CUSUM values (operating time and success), both of them showing three well-differentiated phases: phase 1 (the initial 9-11 cases), phase 2 (the middle 12 cases) and phase 3 (the remaining 20-22 cases). Phase 1 represents initial learning; phase 2 plateau represents increased competence in the use of the robotic system, and finally, phase 3 represents the period of highest skill or mastery with a reduction in docking time (p = 0.000), but a slight increase in operative time (p = 0.007). The CUSUM curve shows three phases in the learning and use of robotic assisted rectal cancer surgery which correspond to the phases of initial learning of the technique, consolidation and higher expertise or mastery. The data obtained suggest that the estimated learning curve for robotic assisted rectal cancer

  14. Device for the alternative option of temperature measurement

    NASA Astrophysics Data System (ADS)

    Jargus, Jan; Nedoma, Jan; Fajkus, Marcel; Novak, Martin; Cubik, Jakub; Cvejn, Daniel; Vasinek, Vladimir

    2017-10-01

    Polydimethylsiloxane (PDMS) has good optical properties, and its composition offers the possibility of use in many applications (industry, security device, medicine applications and etc.). We focused on the alternative option of temperature measurement in this article. Our approach is based on measuring changes of chromaticity correlated temperature corresponding to changes in temperature. Described device uses an optical fiber with a defined layer of PDMS and luminophore and we assume that it can find use also in the field of security. The article describes the process of making the prototype of the device and its verification based on laboratory results. The measured temperature depends mainly on the type of optical fiber and the measured temperature range is determined by the thermal resistance of used optical fiber. Using a calibration measurement can determine the value of temperature with an accuracy of +/- 2,5 %.

  15. GABA-A receptors in mPOAH simultaneously regulate sleep and body temperature in freely moving rats.

    PubMed

    Jha, S K; Yadav, V; Mallick, B N

    2001-09-01

    Sleep-wakefulness and body temperature are two circadian rhythmic biological phenomena. The role of GABAergic inputs in the medial preoptico-anterior hypothalamus (mPOAH) on simultaneous regulation of those phenomena was investigated in freely moving normally behaving rats. The GABA-A receptors were blocked by microinjecting picrotoxin, and the effects on electrophysiological parameters signifying sleep-wakefulness, rectal temperature and brain temperature were recorded simultaneously. The results suggest that, normally, GABA in the medial preoptic area acts through GABA-A receptor that induces sleep and prevents an excessive rise in body temperature. However, the results do not allow us to comment on the cause and effect relationship, if any, between changes in sleep-wakefulness and body temperature. The changes in brain and rectal temperatures showed a positive correlation, however, the former varied within a narrower range than that of the latter.

  16. Operational methods of thermodynamics. Volume 1 - Temperature measurement

    NASA Astrophysics Data System (ADS)

    Eder, F. X.

    The principles of thermometry are examined, taking into account the concept of temperature, the Kelvin scale, the statistical theory of heat, negative absolute temperatures, the thermodynamic temperature scale, the thermodynamic temperature scale below 1 K, noise thermometry, temperature scales based on black-body radiation, acoustical thermometry, and the International Practical Temperature Scale 1968. Aspects of practical temperature measurement are discussed, giving attention to thermometers based on the expansion of a gas or a liquid, instruments utilizing the relative thermal expansion of two different metals, devices measuring the vapor pressure of a liquid, thermocouples, resistance thermometers, radiation pyrometers of various types, instruments utilizing the temperature dependence of a number of material characteristics, devices for temperature control, thermometer calibration, and aspects of thermometer installation and inertia. A description is presented of the approaches employed for the measurement of low temperatures.

  17. Measurement of the temperature distribution inside the power cable using distributed temperature system

    NASA Astrophysics Data System (ADS)

    Jaros, Jakub; Liner, Andrej; Papes, Martin; Vasinek, Vladimir; Mach, Veleslav; Hruby, David; Kajnar, Tomas; Perecar, Frantisek

    2015-01-01

    Nowadays, the power cables are manufactured to fulfill the following condition - the highest allowable temperature of the cable during normal operation and the maximum allowable temperature at short circuit conditions cannot exceed the condition of the maximum allowable internal temperature. The distribution of the electric current through the conductor leads to the increase of the amplitude of electrons in the crystal lattice of the cables material. The consequence of this phenomenon is the increase of friction and the increase of collisions between particles inside the material, which causes the temperature increase of the carrying elements. The temperature increase is unwanted phenomena, because it is causing losses. In extreme cases, the long-term overload leads to the cable damaging or fire. This paper deals with the temperature distribution measurement inside the power cables using distributed temperature system. With cooperation with Kabex company, the tube containing optical fibers was installed into the center of power cables. These fibers, except telecommunications purposes, can be also used as sensors in measurements carrying out with distributed temperature system. These systems use the optical fiber as a sensor and allow the continual measurement of the temperature along the whole cable in real time with spatial resolution 1 m. DTS systems are successfully deployed in temperature measurement applications in industry areas yet. These areas include construction, drainage, hot water etc. Their advantages are low cost, resistance to electromagnetic radiation and the possibility of real time monitoring at the distance of 8 km. The location of the optical fiber in the center of the power cable allows the measurement of internal distribution of the temperature during overloading the cable. This measurement method can be also used for prediction of short-circuit and its exact location.

  18. Dose-distance metric that predicts late rectal bleeding in patients receiving radical prostate external-beam radiotherapy

    NASA Astrophysics Data System (ADS)

    Lee, Richard; Chan, Elisa K.; Kosztyla, Robert; Liu, Mitchell; Moiseenko, Vitali

    2012-12-01

    The relationship between rectal dose distribution and the incidence of late rectal complications following external-beam radiotherapy has been previously studied using dose-volume histograms or dose-surface histograms. However, they do not account for the spatial dose distribution. This study proposes a metric based on both surface dose and distance that can predict the incidence of rectal bleeding in prostate cancer patients treated with radical radiotherapy. One hundred and forty-four patients treated with radical radiotherapy for prostate cancer were prospectively followed to record the incidence of grade ≥2 rectal bleeding. Radiotherapy plans were used to evaluate a dose-distance metric that accounts for the dose and its spatial distribution on the rectal surface, characterized by a logistic weighting function with slope a and inflection point d0. This was compared to the effective dose obtained from dose-surface histograms, characterized by the parameter n which describes sensitivity to hot spots. The log-rank test was used to determine statistically significant (p < 0.05) cut-off values for the dose-distance metric and effective dose that predict for the occurrence of rectal bleeding. For the dose-distance metric, only d0 = 25 and 30 mm combined with a > 5 led to statistical significant cut-offs. For the effective dose metric, only values of n in the range 0.07-0.35 led to statistically significant cut-offs. The proposed dose-distance metric is a predictor of rectal bleeding in prostate cancer patients treated with radiotherapy. Both the dose-distance metric and the effective dose metric indicate that the incidence of grade ≥2 rectal bleeding is sensitive to localized damage to the rectal surface.

  19. Temperature measurement with industrial color camera devices

    NASA Astrophysics Data System (ADS)

    Schmidradler, Dieter J.; Berndorfer, Thomas; van Dyck, Walter; Pretschuh, Juergen

    1999-05-01

    This paper discusses color camera based temperature measurement. Usually, visual imaging and infrared image sensing are treated as two separate disciplines. We will show, that a well selected color camera device might be a cheaper, more robust and more sophisticated solution for optical temperature measurement in several cases. Herein, only implementation fragments and important restrictions for the sensing element will be discussed. Our aim is to draw the readers attention to the use of visual image sensors for measuring thermal radiation and temperature and to give reasons for the need of improved technologies for infrared camera devices. With AVL-List, our partner of industry, we successfully used the proposed sensor to perform temperature measurement for flames inside the combustion chamber of diesel engines which finally led to the presented insights.

  20. Helicobacter pylori-Negative Primary Rectal MALT Lymphoma: Complete Remission after Radiotherapy

    PubMed Central

    Okamura, Takuma; Suga, Tomoaki; Iwaya, Yugo; Ito, Tetsuya; Yokosawa, Shuichi; Arakura, Norikazu; Ota, Hiroyoshi; Tanaka, Eiji

    2012-01-01

    Rectal mucosa-associated lymphoid tissue (MALT) lymphoma is a rare condition. Although the majority of patients undergo surgical resection, a definitive treatment for rectal MALT lymphoma has not yet been established. In the present study, we report the outcome of radiotherapy in 3 patients with rectal MALT lymphoma. Our cohort ranged from 56 to 65 years of age. The male/female ratio was 1:2, and all patients were in stage I (Lugano classification) of the disease. Endoscopic findings revealed elevated lesions resembling submucosal tumors in 2 patients, and a sessile elevated lesion with a nodular surface in 1 patient. One of the 3 patients underwent magnifying endoscopy with crystal violet staining that demonstrated a type I pit pattern (Kudo's classification) lesion with a broad intervening area caused by the upthrust of the tumor from the submucosa. All patients tolerated radiotherapy at doses of 30 Gy without major complications and achieved complete remission. Follow-up ranged from 13 to 75 months (mean 51.0 months), revealing no recurrence of MALT lymphoma. As such, we propose radiotherapy to be a safe and effective means for treating rectal MALT lymphoma. PMID:22754493

  1. Colostomy and drainage for civilian rectal injuries: is that all?

    PubMed Central

    Burch, J M; Feliciano, D V; Mattox, K L

    1989-01-01

    One hundred consecutive patients with injuries to the extraperitoneal rectum were treated over a ten-year period at an urban trauma center. The mechanisms of injury included firearms in 82 patients, stab wounds in 3 patients, a variety of other penetrating injuries in 10 patients, and in 5 patients the injuries resulted from blunt trauma. Treatment of the rectal injury was determined by the bias of the operating surgeon, the condition of the patient, and the magnitude of the rectal injury. Proximal loop colostomies were performed in 44 patients, diverting colostomies in 51 patients, Hartmann's procedure in 4 patients, and an abdominoperineal resection in 1 patient. Extraperitoneal rectal perforations were closed in 21 patients and the rectum was irrigated free of feces in 46 patients. Transperineal, presacral drainage was used in 93 patients. Infectious complications potentially related to the management of the rectal wound occurred in 11 patients (11%) and included abdominal or pelvic abscesses (4 patients), wound infections (6 patients), rectocutaneous fistulas (3 patients), and missile tract infections (2 patients). Four patients (4%) died as a result of their injuries. Of the therapeutic options available, statistical analysis revealed that only the failure to drain the presacral space increased the likelihood of infectious complications (p = 0.03); however, as it could not be determined with certainty that the use of, or failure to use, any particular therapeutic option had an effect on the risk of death. It is concluded that colostomy and drainage are the foundations of the successful treatment of civilian injuries to the extraperitoneal rectum. The use of adjuncts such as diverting colostomies, repair of the rectal wound, and irrigation of the rectum has little effect on mortality and morbidity. PMID:2705824

  2. [Efficacy of retained rectal posterior mucosa in procedure for prolapse and hemorrhoids].

    PubMed

    Zheng, Chenguo; Jin, Chun; Lian, Shaoxiong; Jin, Dingguo

    2014-12-01

    To evaluate the efficacy and necessity of retained rectal posterior mucosa in procedure for prolapse and hemorrhoids (PPH). Clinical data of 260 cases with severe hemorrhoids in our hospital from January 2010 to May 2012 were analyzed retrospectively. A total of 132 cases with severe hemorrhoids excluding in rectal posterior wall were enrolled in retained rectal posterior mucosa in PPH (improvement group), other 128 cases of severe hemorrhoids were assigned to PPH (conventional group). Operative parameters, efficacy and complication after operation were compared. Two groups of patients received successful operations. Postoperative pain duration, frequency of analgesic drugs and postoperative hospital stay in improvement group were significantly reduced [(1.3 ± 0.5) d vs. (4.8 ± 0.7) d, 1.1 ± 0.3 vs. 5.9 ± 0.6, (5.2 ± 0.8) d vs. (5.8 ± 0.5) d, all P<0.01]. Incidence of anastomotic stenosis, heavy feeling in the anus and delayed bleeding in improvement group were significantly lower than those in conventional group (0 vs. 7.8%, 0.8% vs. 14.1%, 0 vs.7.8%, all P<0.01). The application of retained rectal posterior mucosa in PPH to patients with severe hemorrhoids excluding in rectal posterior wall can significantly reduce postoperative complications. But long-term efficacy needs further observation.

  3. Knowledge, Attitudes, and Practices Related to Preoperative Chemoradiotherapy in Rectal Cancer Patients.

    PubMed

    Chen, Xingxing; Lin, Ruifang; Li, Huifang; Su, Meng; Zhang, Wenyi; Deng, Xia; Zhang, Ping; Zou, Changlin

    2016-01-01

    Background . The aim of this study is to assess the knowledge, attitudes, and practices related to pre-CRT in patients of stage II/III rectal cancer. Materials and Methods . Questionnaires regarding the knowledge, attitudes, and practices of pre-CRT were mailed to 145 rectal cancer patients in II/III stage between January 2012 and December 2014, and 111 agreed to participate and returned completed questionnaires to the researcher. Logistic regression model was used to compare sociodemographic characteristics, knowledge, and attitude with practice, respectively. Results . A total of 145 patients were approached for interview, of which 111 responded and 48.6% (54) had undergone pre-CRT. Only 31.5% of the participants knew that CRT is a treatment of rectal cancer and 39.6% were aware of the importance of CRT. However, the vast majority of participants (68.5%) expressed a positive attitude toward rectal cancer. Multivariate logistic regression analysis revealed that knowledge level ( p = 0.006) and attitudes ( p = 0.001) influence the actual practice significantly. Furthermore, age, gender, and income were potential predictors of practice (all p < 0.05). Conclusion . This study shows that, despite the fact that participants had suboptimal level of knowledge on rectal cancer, their attitude is favorable to pre-CRT. Strengthening the professional health knowledge and realizing the importance of attitudes may deepen patients' understanding of preoperative therapy.

  4. In vivo cryoablation of prostate tissue with temperature monitoring by optoacoustic imaging

    NASA Astrophysics Data System (ADS)

    Petrova, Elena V.; Motamedi, Massoud; Oraevsky, Alexander A.; Ermilov, Sergey A.

    2016-03-01

    Cryoablation of prostate cancer is an FDA approved clinical procedure, which involves repetitive rapid cooling of a lesion to lethal temperatures of -40°C and below. The major drawback of the technique is the insufficient control over the fast thermal processes that may result in severe complications (impotence, incontinence, perforation of the rectal wall) and morbidity. The developed optoacoustic imaging technique provides non-invasive real-time temperature mapping of tissue adjacent to prostate and enables more efficient control over the procedure, which is necessary to reduce side effects and accelerate the physician's learning curve. In these studies we successfully demonstrated real-time transrectal optoacoustic imaging during prostate cryoablation in live canine model focused on optoacoustic thermography of the rectal wall within the depth of 1cm. Our method utilized previously discovered universal thermal dependence of the normalized optoacoustic response of blood. Nanosecond-pulse radiation of Ti-Sapphire laser tuned to the isosbestic point of hemoglobin (802+/-3 nm) was delivered via fiberoptic illuminators assembled on both sides of the linear array of the 128-channel transrectal ultrasound probe. Temperature readouts at discrete locations inside and nearby prostate were also performed using standard transperineal needle sensors. The effect of homeostasis on optoacoustic imaging in live tissue was examined during cooling and shown to be significant only within the range of +/-1.5°C in respect to the body temperature. Accuracy of in vivo optoacoustic temperature measurements was determined as +/-2°C for the range of temperature from +35 to -15°C, which is more than sufficient for tracking the essential isotherms in the course of clinical procedures.

  5. Improving the spectral measurement accuracy based on temperature distribution and spectra-temperature relationship

    NASA Astrophysics Data System (ADS)

    Li, Zhe; Feng, Jinchao; Liu, Pengyu; Sun, Zhonghua; Li, Gang; Jia, Kebin

    2018-05-01

    Temperature is usually considered as a fluctuation in near-infrared spectral measurement. Chemometric methods were extensively studied to correct the effect of temperature variations. However, temperature can be considered as a constructive parameter that provides detailed chemical information when systematically changed during the measurement. Our group has researched the relationship between temperature-induced spectral variation (TSVC) and normalized squared temperature. In this study, we focused on the influence of temperature distribution in calibration set. Multi-temperature calibration set selection (MTCS) method was proposed to improve the prediction accuracy by considering the temperature distribution of calibration samples. Furthermore, double-temperature calibration set selection (DTCS) method was proposed based on MTCS method and the relationship between TSVC and normalized squared temperature. We compare the prediction performance of PLS models based on random sampling method and proposed methods. The results from experimental studies showed that the prediction performance was improved by using proposed methods. Therefore, MTCS method and DTCS method will be the alternative methods to improve prediction accuracy in near-infrared spectral measurement.

  6. Diclofenac rectal suppository: an effective modality for perineal pain.

    PubMed

    Naz, Shabnam; Memon, Naila Yousuf; Sattar, Asma; Baloch, Rafia

    2016-08-01

    To determine the frequency of perineal pain after childbirth after a single dose of diclofenac rectal suppository. This cross-sectional study was conducted at Shaikh Zayed Women Hospital, Larkana, Pakistan, from April to September 2014, and comprised patients who were admitted to the labour room for normal vaginal delivery. A single dose of rectal diclofenac suppository of 100mg was given to the patients delivered vaginally or by second-stage emergency Caesarean section. Post-partum pain was noted after 12 and 24 hours of the administration of analgesia. SPSS 16 was used for data analysis. Of the 169 subjects, 63(37.28%) were aged 20 years or less, 85(50.3%) between 21 and 30 years, and 21(12.43%) between 31 and 40 years. Frequency of perineal pain was predominantly mild in 95(56%) patients, moderate in 60(35.5%) and severe in 14(8.28%). The use of non-steroidal anti-inflammatory rectal suppositories was found to be a simple and highly effective modality of reducing the perineal pain.

  7. SwiftLase: a new technology for char-free ablation in rectal surgery

    NASA Astrophysics Data System (ADS)

    Arnold, David A.

    1995-05-01

    We describe layer-by-layer char-free ablation of hemorrhoids and other rectal lesions at very low CO2 laser power levels with a miniature `SwiftLaser' optomechanical flashscanner. Increased speed with excellent control, very shallow thermal damage, and less postoperative pain are the main advantages of the flashscan technology in rectal surgery.

  8. Dynamic gas temperature measurement system

    NASA Technical Reports Server (NTRS)

    Elmore, D. L.; Robinson, W. W.; Watkins, W. B.

    1983-01-01

    A gas temperature measurement system with compensated frequency response of 1 KHz and capability to operate in the exhaust of a gas turbine combustor was developed. Environmental guidelines for this measurement are presented, followed by a preliminary design of the selected measurement method. Transient thermal conduction effects were identified as important; a preliminary finite-element conduction model quantified the errors expected by neglecting conduction. A compensation method was developed to account for effects of conduction and convection. This method was verified in analog electrical simulations, and used to compensate dynamic temperature data from a laboratory combustor and a gas turbine engine. Detailed data compensations are presented. Analysis of error sources in the method were done to derive confidence levels for the compensated data.

  9. Temperature measurement reliability and validity with thermocouple extension leads or changing lead temperature.

    PubMed

    Jutte, Lisa S; Long, Blaine C; Knight, Kenneth L

    2010-01-01

    Thermocouples' leads are often too short, necessitating the use of an extension lead. To determine if temperature measures were influenced by extension-lead use or lead temperature changes. Descriptive laboratory study. Laboratory. Experiment 1: 10 IT-21 thermocouples and 5 extension leads. Experiment 2: 5 IT-21 and PT-6 thermocouples. In experiment 1, temperature data were collected on 10 IT-21 thermocouples in a stable water bath with and without extension leads. In experiment 2, temperature data were collected on 5 IT-21 and PT-6 thermocouples in a stable water bath before, during, and after ice-pack application to extension leads. In experiment 1, extension leads did not influence IT-21 validity (P  =  .45) or reliability (P  =  .10). In experiment 2, postapplication IT-21 temperatures were greater than preapplication and application measures (P < .05). Extension leads had no influence on temperature measures. Ice application to leads may increase measurement error.

  10. Nd:YAG laser therapy for rectal and vaginal venous malformations.

    PubMed

    Gurien, Lori A; Jackson, Richard J; Kiser, Michelle M; Richter, Gresham T

    2017-08-01

    Limited therapeutic options exist for rectal and vaginal venous malformations (VM). We describe our center's experience using Nd:YAG laser for targeted ablation of abnormal veins to treat mucosally involved pelvic VM. Records of patients undergoing non-contact Nd:YAG laser therapy of pelvic VM at a tertiary children's hospital were reviewed. Symptoms, operative findings and details, complications, and outcomes were evaluated. Nine patients (age 0-24) underwent Nd:YAG laser therapy of rectal and/or vaginal VM. Rectal bleeding was present in all patients and vaginal bleeding in all females (n = 5). 5/7 patients had extensive pelvic involvement on MRI. Typical settings were 30 (rectum) and 20-25 W (vagina), with 0.5-1.0 s pulse duration. Patients underwent the same-day discharge. Treatment intervals ranged from 14 to 180 (average = 56) weeks, with 6.1-year mean follow-up. Five patients experienced symptom relief with a single treatment. Serial treatments managed recurrent bleeding successfully in all patients, with complete resolution of vaginal lesions in 40% of cases. No complications occurred. Nd:YAG laser treatment of rectal and vaginal VM results in substantial improvement and symptom control, with low complication risk. Given the high morbidity of surgical resection, Nd:YAG laser treatment of pelvic VM should be considered as first line therapy.

  11. Irinotecan-encapsulated double-reverse thermosensitive nanocarrier system for rectal administration.

    PubMed

    Din, Fakhar Ud; Choi, Ju Yeon; Kim, Dong Wuk; Mustapha, Omer; Kim, Dong Shik; Thapa, Raj Kumar; Ku, Sae Kwang; Youn, Yu Seok; Oh, Kyung Taek; Yong, Chul Soon; Kim, Jong Oh; Choi, Han-Gon

    2017-11-01

    Intravenously administered for the treatment of rectum cancer, irinotecan produces severe side effects due to very high plasma concentrations. A novel irinotecan-encapsulated double reverse thermosensitive nanocarrier system (DRTN) for rectal administration was developed as an alternative. The DRTN was fabricated by dispersing the thermosensitive irinotecan-encapsulated solid lipid nanoparticles (SLN) in the thermosensitive poloxamer solution. Its gel properties, pharmacokinetics, morphology, anticancer activity and immunohistopathology were assessed after its rectal administration to rats and tumor-bearing mice. In the DRTN, the solid form of the SLN and the liquid form of the poloxamer solution persisted at 25 °C; the former melted to liquid, and the latter altered to gel at 36.5 °C. The DRTN was easily administered to the anus, gelling rapidly and strongly after rectal administration. Compared to the conventional hydrogel and intravenously administered solution, it retarded dissolution and initial plasma concentration. The DRTN gave sustained release and nearly constant plasma concentrations of irinotecan at 1-3 h in rats, resulting in improved anticancer activity. It induced no damage to the rat rectum and no body weight loss in tumor-bearing mice. Thus, this irinotecan-encapsulated DRTN associated with a reduced burst effect, lack of toxicity and excellent antitumor efficacy would be strongly recommended as a rectal pharmaceutical product alternative to commercial intravenous injection in the treatment of rectum and colon cancer.

  12. Whither papillon? Future directions for contact radiotherapy in rectal cancer.

    PubMed

    Lindegaard, J; Gerard, J P; Sun Myint, A; Myerson, R; Thomsen, H; Laurberg, S

    2007-11-01

    Although contact radiotherapy was developed 70 years ago, and is highly effective with cure rates of over 90% for early rectal cancer, there are few centres that offer this treatment today. One reason is the lack of replacement of ageing contact X-ray machines, many of which are now over 30 years old. To address this problem, the International Contact Radiotherapy Evaluation (ICONE) group was formed at a meeting in Liverpool in 2005 with the aim of developing a new contact X-ray unit and to establish clinical protocols that would enable the new machine to safely engage in the treatment of rectal cancer. As a result of these efforts, a European company is starting production of the new Papillon RT-50 machine, which will be available shortly. In addition, the ICONE group is planning an observational study on contact X-ray and transanal endoscopic microsurgery (CONTEM) for curative treatment of rectal cancer. This protocol will ensure standardised diagnostic procedures, patient selection and treatment in centres across the world and the data will be collected prospectively for analysis and audit. It is hoped that the CONTEM trial will provide the scientific evidence that is needed to obtain a broader acceptance of local contact radiotherapy as a treatment option for selected cases with early stage rectal cancer.

  13. Embolization of Rectal Arteries: An Alternative Treatment for Hemorrhagic Shock Induced by Traumatic Intrarectal Hemorrhage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pichon, Nicolas, E-mail: nicolas.pichon@unilim.fr, E-mail: nicolas.pichon@chu-limoges.fr; Francois, Bruno; Pichon-Lefievre, Florence

    2005-05-15

    Rectal injuries caused by foreign bodies or iatrogenic insertions may lead to severe complications whose therapeutic management remains controversial. At times, both the rapid identification and treatment of subsequent active rectal bleeding may be challenging, especially when endoscopy fails to locate and control the arterial hemorrhage. We present the first two successful cases of middle rectal artery embolization in patients presenting with sustained bleeding and hemorrhagic shock.

  14. Outdoor surface temperature measurement: ground truth or lie?

    NASA Astrophysics Data System (ADS)

    Skauli, Torbjorn

    2004-08-01

    Contact surface temperature measurement in the field is essential in trials of thermal imaging systems and camouflage, as well as for scene modeling studies. The accuracy of such measurements is challenged by environmental factors such as sun and wind, which induce temperature gradients around a surface sensor and lead to incorrect temperature readings. In this work, a simple method is used to test temperature sensors under conditions representative of a surface whose temperature is determined by heat exchange with the environment. The tested sensors are different types of thermocouples and platinum thermistors typically used in field trials, as well as digital temperature sensors. The results illustrate that the actual measurement errors can be much larger than the specified accuracy of the sensors. The measurement error typically scales with the difference between surface temperature and ambient air temperature. Unless proper care is taken, systematic errors can easily reach 10% of this temperature difference, which is often unacceptable. Reasonably accurate readings are obtained using a miniature platinum thermistor. Thermocouples can perform well on bare metal surfaces if the connection to the surface is highly conductive. It is pointed out that digital temperature sensors have many advantages for field trials use.

  15. Management of stage IV rectal cancer: Palliative options

    PubMed Central

    Ronnekleiv-Kelly, Sean M; Kennedy, Gregory D

    2011-01-01

    Approximately 30% of patients with rectal cancer present with metastatic disease. Many of these patients have symptoms of bleeding or obstruction. Several treatment options are available to deal with the various complications that may afflict these patients. Endorectal stenting, laser ablation, and operative resection are a few of the options available to the patient with a malignant large bowel obstruction. A thorough understanding of treatment options will ensure the patient is offered the most effective therapy with the least amount of associated morbidity. In this review, we describe various options for palliation of symptoms in patients with metastatic rectal cancer. Additionally, we briefly discuss treatment for asymptomatic patients with metastatic disease. PMID:21412493

  16. Factors of Pelvic Infection and Death in Patients with Open Pelvic Fractures and Rectal Injuries.

    PubMed

    Song, Wenhao; Zhou, Dongsheng; Xu, Weicheng; Zhang, Guoming; Wang, Chunhui; Qiu, Daodi; Dong, Jinlei

    Open pelvic fractures associated with rectal injuries are uncommon. They often cause serious pelvic infection, even death. This combination of injuries has been reviewed infrequently. Herein, we report factors associated with pelvic infection and death in a group of patients with open pelvic fractures and concurrent rectal injuries. We retrospectively reviewed the records of patients with open pelvic fractures and rectal injuries who were treated at our institution from January 2010-April 2014. From the medical records, age, gender, Injury Severity Score (ISS), cause of fracture, associated injuries, classification of the fracture, degree of soft-tissue injury, Glasgow Coma Score (GCS), Revised Trauma Score (RTS), packed red blood cells (PRBCs) needed, presence/absence of shock, early colostomy (yes or no), drainage (yes or no), and rectal washout (yes or no) were extracted. Univariable and multivariable analysis were performed to determine the association between risk factors and pelvic infection or death. Twenty patients were identified. Pelvic infection occurred in 50% (n = 10) of the patients. Four patients suffered septicemia, and three patients died of multiple organ dysfunction. The mortality rate thus was 15%. According to the univariable analysis, the patients in whom pelvic infection developed had shock, RTS ≤8, GCS ≤8, blood transfusion ≥10 units in the first 24 h, no colostomy, or Gustilo grade III soft-tissue injury. According to the multivariable analysis, shock and absence of colostomy were independently associated with pelvic infection. By univariable analysis, the only factor associated with death was RTS ≤8. The incidence of pelvic infection was lower in patients having early colostomy (p < 0.05). Patients with shock had a higher risk of pelvic infection, and we recommend aggressive measures to treat these patients. According to our results, RTS ≤8 could be a predictor of poor outcomes in patients with open pelvic fracture and

  17. Studies on the absorption and disposition of meptazinol following rectal administration.

    PubMed Central

    Franklin, R A; Southgate, P J; Coleman, A J

    1977-01-01

    1 Rectal administration of the new analgesic drug, meptazinol, resulted in rapid absorption of the compound both in the monkey and in man. Peak plasma levels were observed within 0.5 h of dosing. 2 Absorption of the drug following rectal administration was extensive as shown by the recovery of 65-90% of the dose in the urine. 3 Despite substantial inter-individual variation in the observed maximum plasma concentrations of the drug, it was still evident that concentrations after rectal dosage were considerably higher than when the same dosage was given orally. 4 Elimination of the drug from plasma took place rapidly in an apparently mono-exponential manner in both species. The half-life of elimination in monkeys was 1.25 h and in man 2.0 h. PMID:405029

  18. Temperature Measurements Taken by Phoenix Spacecraft

    NASA Image and Video Library

    2008-09-30

    This chart plots the minimum daily atmospheric temperature measured by NASA Phoenix Mars Lander spacecraft since landing on Mars. As the temperature increased through the summer season, the atmospheric humidity also increased.

  19. MicroRNA Expression Profiling to Identify and Validate Reference Genes for the Relative Quantification of microRNA in Rectal Cancer.

    PubMed

    Eriksen, Anne Haahr Mellergaard; Andersen, Rikke Fredslund; Pallisgaard, Niels; Sørensen, Flemming Brandt; Jakobsen, Anders; Hansen, Torben Frøstrup

    2016-01-01

    MicroRNAs (miRNAs) play important roles in regulating biological processes at the post-transcriptional level. Deregulation of miRNAs has been observed in cancer, and miRNAs are being investigated as potential biomarkers regarding diagnosis, prognosis and prediction in cancer management. Real-time quantitative polymerase chain reaction (RT-qPCR) is commonly used, when measuring miRNA expression. Appropriate normalisation of RT-qPCR data is important to ensure reliable results. The aim of the present study was to identify stably expressed miRNAs applicable as normaliser candidates in future studies of miRNA expression in rectal cancer. We performed high-throughput miRNA profiling (OpenArray®) on ten pairs of laser micro-dissected rectal cancer tissue and adjacent stroma. A global mean expression normalisation strategy was applied to identify the most stably expressed miRNAs for subsequent validation. In the first validation experiment, a panel of miRNAs were analysed on 25 pairs of micro dissected rectal cancer tissue and adjacent stroma. Subsequently, the same miRNAs were analysed in 28 pairs of rectal cancer tissue and normal rectal mucosa. From the miRNA profiling experiment, miR-645, miR-193a-5p, miR-27a and let-7g were identified as stably expressed, both in malignant and stromal tissue. In addition, NormFinder confirmed high expression stability for the four miRNAs. In the RT-qPCR based validation experiments, no significant difference between tumour and stroma/normal rectal mucosa was detected for the mean of the normaliser candidates miR-27a, miR-193a-5p and let-7g (first validation P = 0.801, second validation P = 0.321). MiR-645 was excluded from the data analysis, because it was undetected in 35 of 50 samples (first validation) and in 24 of 56 samples (second validation), respectively. Significant difference in expression level of RNU6B was observed between tumour and adjacent stromal (first validation), and between tumour and normal rectal mucosa (second

  20. Noncontact Measurement of Humidity and Temperature Using Airborne Ultrasound

    NASA Astrophysics Data System (ADS)

    Kon, Akihiko; Mizutani, Koichi; Wakatsuki, Naoto

    2010-04-01

    We describe a noncontact method for measuring humidity and dry-bulb temperature. Conventional humidity sensors are single-point measurement devices, so that a noncontact method for measuring the relative humidity is required. Ultrasonic temperature sensors are noncontact measurement sensors. Because water vapor in the air increases sound velocity, conventional ultrasonic temperature sensors measure virtual temperature, which is higher than dry-bulb temperature. We performed experiments using an ultrasonic delay line, an atmospheric pressure sensor, and either a thermometer or a relative humidity sensor to confirm the validity of our measurement method at relative humidities of 30, 50, 75, and 100% and at temperatures of 283.15, 293.15, 308.15, and 323.15 K. The results show that the proposed method measures relative humidity with an error rate of less than 16.4% and dry-bulb temperature with an error of less than 0.7 K. Adaptations of the measurement method for use in air-conditioning control systems are discussed.