Sample records for reduction measuring performance

  1. Formation Flight System Extremum-Seeking-Control Using Blended Performance Parameters

    NASA Technical Reports Server (NTRS)

    Ryan, John J. (Inventor)

    2018-01-01

    An extremum-seeking control system for formation flight that uses blended performance parameters in a conglomerate performance function that better approximates drag reduction than performance functions formed from individual measurements. Generally, a variety of different measurements are taken and fed to a control system, the measurements are weighted, and are then subjected to a peak-seeking control algorithm. As measurements are continually taken, the aircraft will be guided to a relative position which optimizes the drag reduction of the formation. Two embodiments are discussed. Two approaches are shown for determining relative weightings: "a priori" by which they are qualitatively determined (by minimizing the error between the conglomerate function and the drag reduction function), and by periodically updating the weightings as the formation evolves.

  2. Methods of Constructing a Blended Performance Function Suitable for Formation Flight

    NASA Technical Reports Server (NTRS)

    Ryan, Jack

    2017-01-01

    Two methods for constructing performance functions for formation fight-for-drag-reduction suitable for use with an extreme-seeking control system are presented. The first method approximates an a prior measured or estimated drag-reduction performance function by combining real-time measurements of readily available parameters. The parameters are combined with weightings determined from a minimum squares optimization to form a blended performance function.

  3. Experimental evaluation of leaky least-mean-square algorithms for active noise reduction in communication headsets.

    PubMed

    Cartes, David A; Ray, Laura R; Collier, Robert D

    2002-04-01

    An adaptive leaky normalized least-mean-square (NLMS) algorithm has been developed to optimize stability and performance of active noise cancellation systems. The research addresses LMS filter performance issues related to insufficient excitation, nonstationary noise fields, and time-varying signal-to-noise ratio. The adaptive leaky NLMS algorithm is based on a Lyapunov tuning approach in which three candidate algorithms, each of which is a function of the instantaneous measured reference input, measurement noise variance, and filter length, are shown to provide varying degrees of tradeoff between stability and noise reduction performance. Each algorithm is evaluated experimentally for reduction of low frequency noise in communication headsets, and stability and noise reduction performance are compared with that of traditional NLMS and fixed-leakage NLMS algorithms. Acoustic measurements are made in a specially designed acoustic test cell which is based on the original work of Ryan et al. ["Enclosure for low frequency assessment of active noise reducing circumaural headsets and hearing protection," Can. Acoust. 21, 19-20 (1993)] and which provides a highly controlled and uniform acoustic environment. The stability and performance of the active noise reduction system, including a prototype communication headset, are investigated for a variety of noise sources ranging from stationary tonal noise to highly nonstationary measured F-16 aircraft noise over a 20 dB dynamic range. Results demonstrate significant improvements in stability of Lyapunov-tuned LMS algorithms over traditional leaky or nonleaky normalized algorithms, while providing noise reduction performance equivalent to that of the NLMS algorithm for idealized noise fields.

  4. Modelling of different measures for improving removal in a stormwater pond.

    PubMed

    German, J; Jansons, K; Svensson, G; Karlsson, D; Gustafsson, L G

    2005-01-01

    The effect of retrofitting an existing pond on removal efficiency and hydraulic performance was modelled using the commercial software Mike21 and compartmental modelling. The Mike21 model had previously been calibrated on the studied pond. Installation of baffles, the addition of culverts under a causeway and removal of an existing island were all studied as possible improvement measures in the pond. The subsequent effect on hydraulic performance and removal of suspended solids was then evaluated. Copper, cadmium, BOD, nitrogen and phosphorus removal were also investigated for that specific improvement measure showing the best results. Outcomes of this study reveal that all measures increase the removal efficiency of suspended solids. The hydraulic efficiency is improved for all cases, except for the case where the island is removed. Compartmental modelling was also used to evaluate hydraulic performance and facilitated a better understanding of the way each of the different measures affected the flow pattern and performance. It was concluded that the installation of baffles is the best of the studied measures resulting in a reduction in the annual load on the receiving lake by approximately 8,000 kg of suspended solids (25% reduction of the annual load), 2 kg of copper (10% reduction of the annual load) and 600 kg of BOD (10% reduction of the annual load).

  5. 40 CFR 63.116 - Process vent provisions-performance test methods and procedures to determine compliance.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... conduct a performance test to determine percent emission reduction or outlet organic HAP or TOC... organic HAP concentration and percent reduction may be measured as either total organic HAP or as TOC... measurement of total organic HAP or TOC (minus methane and ethane) concentrations in all vent streams and...

  6. Reduction of nocturnal slow-wave activity affects daytime vigilance lapses and memory encoding but not reaction time or implicit learning.

    PubMed

    Van Der Werf, Ysbrand D; Altena, Ellemarije; Vis, José C; Koene, Teddy; Van Someren, Eus J W

    2011-01-01

    Total sleep deprivation in healthy subjects has a profound effect on the performance on tasks measuring sustained attention or vigilance. We here report how a selective disruption of deep sleep only, that is, selective slow-wave activity (SWA) reduction, affects the performance of healthy well-sleeping subjects on several tasks: a "simple" and a "complex" vigilance task, a declarative learning task, and an implicit learning task despite unchanged duration of sleep. We used automated electroencephalogram (EEG) dependent acoustic feedback aimed at selective interference with-and reduction of-SWA. In a within-subject repeated measures crossover design, performance on the tasks was assessed in 13 elderly adults without sleep complaints after either SWA-reduction or after normal sleep. The number of vigilance lapses increased as a result of SWA reduction, irrespective of the type of vigilance task. Recognition on the declarative memory task was also affected by SWA reduction, associated with a decreased activation of the right hippocampus on encoding (measured with fMRI) suggesting a weaker memory trace. SWA reduction, however, did not affect reaction time on either of the vigilance tasks or implicit memory task performance. These findings suggest a specific role of slow oscillations in the subsequent daytime ability to maintain sustained attention and to encode novel declarative information but not to maintain response speed or to build implicit memories. Of particular interest is that selective SWA reduction can mimic some of the effects of total sleep deprivation, while not affecting sleep duration. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. Handbook of recommended practices for the determination of liquid monopropellant rocket engine performance

    NASA Technical Reports Server (NTRS)

    Bjorklund, R. A.; Rogero, R. S.; Baerwald, R. K.

    1979-01-01

    The design, installation, and operation of systems to be used for directly measuring quantities of fundamental importance to the determination of monopropellant thruster performance is described. Areas covered include: (1) force and impulse measurement; (2) propellant mass usage and flow measurement; (3) pressure measurement; (4) temperature measurement; (5) exhaust gas composition measurement; and (6) data reduction and performance determination.

  8. Value and impact of international hospital accreditation: a case study from Jordan.

    PubMed

    Halasa, Y A; Zeng, W; Chappy, E; Shepard, D S

    2015-04-02

    We assessed the economic impact of Joint Commission International hospital accreditation on 5 structural and outcome hospital performance measures in Jordan. We conducted a 4-year retrospective study comparing 2 private accredited acute general hospitals with matched non-accredited hospitals, using difference-in-differences and adjusted covariance analyses to test the impact and value of accreditation on hospital performance measures. Of the 5 selected measures, 3 showed statistically significant effects (all improvements) associated with accreditation: reduction in return to intensive care unit (ICU) within 24 hours of ICU discharge; reduction in staff turnover; and completeness of medical records. The net impact of accreditation was a 1.2 percentage point reduction in patients who returned to the ICU, 12.8% reduction in annual staff turnover and 20.0% improvement in the completeness of medical records. Pooling both hospitals over 3 years, these improvements translated into total savings of US$ 593 000 in Jordan's health-care system.

  9. Smith machine counterbalance system affects measures of maximal bench press throw performance.

    PubMed

    Vingren, Jakob L; Buddhadev, Harsh H; Hill, David W

    2011-07-01

    Equipment with counterbalance weight systems is commonly used for the assessment of performance in explosive resistance exercise movements, but it is not known if such systems affect performance measures. The purpose of this study was to determine the effect of using a counterbalance weight system on measures of smith machine bench press throw performance. Ten men and 14 women (mean ± SD: age, 25 ± 4 years; height, 173 ± 10 cm; weight, 77.7 ± 18.3 kg) completed maximal smith machine bench press throws under 4 different conditions (2 × 2; counterbalance × load): with or without a counterbalance weight system and using 'light' or 'moderate' net barbell loads. Performance variables (peak force, peak velocity, and peak power) were measured using a linear accelerometer attached to the barbell. The counterbalance weight system resulted in significant (p < 0.001) reductions in measures of peak force (mean difference ± standard error: light: -112 ± 20 N; moderate: -140 ± 23 N), peak velocity (light: -0.49 ± 0.10 m·s; moderate: -0.33 ± 0.07 m·s), and peak power (light: -220 ± 43 W; moderate: -143 ± 28 W) compared with no counterbalance system for both load conditions. Load condition did not affect absolute or percentage reductions from the counterbalance weight system for any variable. In conclusion, the use of a counterbalance weight system reduces accelerometer-based performance measures for the bench press throw exercise at light and moderate loads. This reduction in measures is likely because of an increase in the external resistance during the movement, which results in a discrepancy between the manually input and the actual value for external load. A counterbalance weight system should not be used when measuring performance in explosive resistance exercises with an accelerometer.

  10. Complication Rates, Hospital Size, and Bias in the CMS Hospital-Acquired Condition Reduction Program.

    PubMed

    Koenig, Lane; Soltoff, Samuel A; Demiralp, Berna; Demehin, Akinluwa A; Foster, Nancy E; Steinberg, Caroline Rossi; Vaz, Christopher; Wetzel, Scott; Xu, Susan

    In 2016, Medicare's Hospital-Acquired Condition Reduction Program (HAC-RP) will reduce hospital payments by $364 million. Although observers have questioned the validity of certain HAC-RP measures, less attention has been paid to the determination of low-performing hospitals (bottom quartile) and the assignment of penalties. This study investigated possible bias in the HAC-RP by simulating hospitals' likelihood of being in the worst-performing quartile for 8 patient safety measures, assuming identical expected complication rates across hospitals. Simulated likelihood of being a poor performer varied with hospital size. This relationship depended on the measure's complication rate. For 3 of 8 measures examined, the equal-quality simulation identified poor performers similarly to empirical data (c-statistic approximately 0.7 or higher) and explained most of the variation in empirical performance by size (Efron's R 2 > 0.85). The Centers for Medicare & Medicaid Services could address potential bias in the HAC-RP by stratifying by hospital size or using a broader "all-harm" measure.

  11. 40 CFR Table 4 to Subpart Zzzz of... - Requirements for Performance Tests

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... determine O2 concentration must be made at the same time as the measurements for formaldehyde or THC... formaldehyde or THC concentration. iv. If demonstrating compliance with the formaldehyde percent reduction...-hour or longer runs. v. If demonstrating compliance with the THC percent reduction requirement, measure...

  12. 40 CFR Table 4 to Subpart Zzzz of... - Requirements for Performance Tests

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... determine O2 concentration must be made at the same time as the measurements for formaldehyde or THC... formaldehyde or THC concentration. iv. If demonstrating compliance with the formaldehyde percent reduction...-hour or longer runs. v. If demonstrating compliance with the THC percent reduction requirement, measure...

  13. Effect of Trailing Edge Flow Injection on Fan Noise and Aerodynamic Performance

    NASA Technical Reports Server (NTRS)

    Fite, E. Brian; Woodward, Richard P.; Podboy, Gary G.

    2006-01-01

    An experimental investigation using trailing edge blowing for reducing fan rotor/guide vane wake interaction noise was completed in the NASA Glenn 9- by 15-foot Low Speed Wind Tunnel. Data were acquired to measure noise, aerodynamic performance, and flow features for a 22" tip diameter fan representative of modern turbofan technology. The fan was designed to use trailing edge blowing to reduce the fan blade wake momentum deficit. The test objective was to quantify noise reductions, measure impacts on fan aerodynamic performance, and document the flow field using hot-film anemometry. Measurements concentrated on approach, cutback, and takeoff rotational speeds as those are the primary conditions of acoustic interest. Data are presented for a 2% (relative to overall fan flow) trailing edge injection rate and show a 2 dB reduction in Overall Sound Power Level (OAPWL) at all fan test speeds. The reduction in broadband noise is nearly constant and is approximately 1.5 dB up to 20 kHz at all fan speeds. Measurements of tone noise show significant variation, as evidenced by reductions of up to 6 dB in the 2 BPF tone at 6700 rpm.: and increases of nearly 2 dB for the 4 BPF tone at approach speed. Aerodynamic performance measurements show the fan with 2 % injection has an overall efficiency that is comparable to the baseline fan and operates, as intended, with nearly the same pressure ratio and mass flow parameters. Hot-film measurements obtained at the approach operating condition indicate that mean blade wake filling in the tip region was not as significant as expected. This suggests that additional acoustic benefits could be realized if the trailing edge blowing could be modified to provide better filling of the wake momentum deficit. Nevertheless, the hot-film measurements indicate that the trailing edge blowing provided significant reductions in blade wake turbulence. Overall, these results indicate that further work may be required to fully understand the proper implementation of injecting flow at/near the trailing edge as a wake filling strategy. However, data do support the notion that noise reductions can be realized not only for tones but perhaps more importantly, also for broadband. Furthermore, the technique can be implemented without adversely effecting overall fan aerodynamic performance.

  14. Design and analysis of a pilot scale biofiltration system for odorous air

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Classen, J.J.; Young, J.S.; Bottcher, R.W.

    2000-02-01

    Three pilot-scale biofilters and necessary peripheral equipment were built to clean odorous air from the pit of a swine gestation building at North Carolina State University. A computer measured temperatures, flow rates, and pressure drops. It also controlled and measured the moisture content of a biofilter medium comprised of a 3:1 mixture of yard waste compost to wood chips mixture (by volume). The system was evaluated to ensure that the biofilters would be useful for performing scientific experiments concerning the reduction of swine odor on future research projects. The capability of the biofilters to remove odor was measured using amore » cotton swatch absorption method and an odor panel. The average odor reductions measured by odor intensity, irritation intensity, and unpleasantness for five tests were 61%, 58%, and 84%, respectively. No significant differences in odor reduction performance were found between the biofilters.« less

  15. FPGA-based architecture for real-time data reduction of ultrasound signals.

    PubMed

    Soto-Cajiga, J A; Pedraza-Ortega, J C; Rubio-Gonzalez, C; Bandala-Sanchez, M; Romero-Troncoso, R de J

    2012-02-01

    This paper describes a novel method for on-line real-time data reduction of radiofrequency (RF) ultrasound signals. The approach is based on a field programmable gate array (FPGA) system intended mainly for steel thickness measurements. Ultrasound data reduction is desirable when: (1) direct measurements performed by an operator are not accessible; (2) it is required to store a considerable amount of data; (3) the application requires measuring at very high speeds; and (4) the physical space for the embedded hardware is limited. All the aforementioned scenarios can be present in applications such as pipeline inspection where data reduction is traditionally performed on-line using pipeline inspection gauges (PIG). The method proposed in this work consists of identifying and storing in real-time only the time of occurrence (TOO) and the maximum amplitude of each echo present in a given RF ultrasound signal. The method is tested with a dedicated immersion system where a significant data reduction with an average of 96.5% is achieved. Copyright © 2011 Elsevier B.V. All rights reserved.

  16. FOLLOW-UP DURABILITY MEASUREMENTS AND MITIGATION PERFORMANCE IMPROVEMENT TESTS IN 38 EASTERN PENNSYL- VANIA HOUSES HAVING INDOOR REDUCTION SYSTEMS

    EPA Science Inventory

    The report gives results of follow-up tests in 38 difficult- to-mitigate Pennsylvania houses where indoor radon reduction systems had been installed 2 to 4 years earlier. bjectives were to assess system durability, methods for improving performance, and methods for reducing insta...

  17. Radiation exposure reduction by use of Kevlar cassettes in the neonatal nursery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Herman, M.W.; Mak, H.K.; Lachman, R.S.

    1987-05-01

    A study was performed to determine whether the use of Kevlar cassettes in the neonatal intensive care nursery would reduce radiation exposure to patients. The radiation dose to the neonates was measured by using thermoluminescent dosimeters. In addition, the attenuation of the Kevlar cassettes and the sensitivity of the film-screen combination were compared with the previously used system. The greatest radiation reduction using a mobile X-ray unit was 27%; based on sensitivity measurements, the theoretical reduction averaged 38%. The reduction in radiation exposure resulted from reduced attenuation by the Kevlar cassette.

  18. Radiation exposure reduction by use of Kevlar cassettes in the neonatal nursery.

    PubMed

    Herman, M W; Mak, H K; Lachman, R S

    1987-05-01

    A study was performed to determine whether the use of Kevlar cassettes in the neonatal intensive care nursery would reduce radiation exposure to patients. The radiation dose to the neonates was measured by using thermoluminescent dosimeters. In addition, the attenuation of the Kevlar cassettes and the sensitivity of the film-screen combination were compared with the previously used system. The greatest radiation reduction using a mobile X-ray unit was 27%; based on sensitivity measurements, the theoretical reduction averaged 38%. The reduction in radiation exposure resulted from reduced attenuation by the Kevlar cassette.

  19. Turnover and organizational performance: a comparative analysis of the effects of voluntary, involuntary, and reduction-in-force turnover.

    PubMed

    McElroy, J C; Morrow, P C; Rude, S N

    2001-12-01

    Data were collected from 31 regional subunits of a national financial services company to examine differential effects of 3 types of turnover (voluntary, involuntary, and reduction-in-force) on measures of organizational subunit performance. Although each form of turnover exhibited adverse effects on subunit performance when examined separately, partial correlation results revealed greater and more pervasive adverse effects for reduction-in-force turnover (i.e., downsizing) in comparison with the effects of voluntary and involuntary turnover. The results confirm the negative effects of downsizing, suggesting the need to move beyond the traditional voluntary-involuntary classification scheme used in turnover research.

  20. Influence of panel fastening on the acoustic performance of light-weight building elements: Study by sound transmission and laser scanning vibrometry

    NASA Astrophysics Data System (ADS)

    Roozen, N. B.; Muellner, H.; Labelle, L.; Rychtáriková, M.; Glorieux, C.

    2015-06-01

    Structural details and workmanship can cause considerable differences in sound insulation properties of timber frame partitions. In this study, the influence of panel fastening is investigated experimentally by means of standardized sound reduction index measurements, supported by detailed scanning laser Doppler vibrometry. In particular the effect of the number of screws used to fasten the panels to the studs, and the tightness of the screws, is studied using seven different configurations of lightweight timber frame building elements. In the frequency range from 300 to 4000 Hz, differences in the weighted sound reduction index RW as large as 10 dB were measured, suggesting that the method of fastening can have a large impact on the acoustic performance of building elements. Using the measured vibrational responses of the element, its acoustic radiation efficiency was computed numerically by means of a Rayleigh integral. The increased radiation efficiency partly explains the reduced sound reduction index. Loosening the screws, or reducing the number of screws, lowers the radiation efficiency, and significantly increases the sound reduction index of the partition.

  1. A Closer Look: Teacher Evaluations and Reduction-in-Force Policies

    ERIC Educational Resources Information Center

    Thomsen, Jennifer

    2014-01-01

    An increasing number of states are requiring teacher performance, as measured by evaluations, be considered when districts are conducting layoffs or reductions in force, according to a 50-state policy review by the Education Commission of the States (ECS). ECS reviewed reduction-in-force policies in 2012 and recently created an online database,…

  2. Operational and environmental performance in China's thermal power industry: Taking an effectiveness measure as complement to an efficiency measure.

    PubMed

    Wang, Ke; Zhang, Jieming; Wei, Yi-Ming

    2017-05-01

    The trend toward a more fiercely competitive and strictly environmentally regulated electricity market in several countries, including China has led to efforts by both industry and government to develop advanced performance evaluation models that adapt to new evaluation requirements. Traditional operational and environmental efficiency measures do not fully consider the influence of market competition and environmental regulations and, thus, are not sufficient for the thermal power industry to evaluate its operational performance with respect to specific marketing goals (operational effectiveness) and its environmental performance with respect to specific emissions reduction targets (environmental effectiveness). As a complement to an operational efficiency measure, an operational effectiveness measure not only reflects the capacity of an electricity production system to increase its electricity generation through the improvement of operational efficiency, but it also reflects the system's capability to adjust its electricity generation activities to match electricity demand. In addition, as a complement to an environmental efficiency measure, an environmental effectiveness measure not only reflects the capacity of an electricity production system to decrease its pollutant emissions through the improvement of environmental efficiency, but it also reflects the system's capability to adjust its emissions abatement activities to fulfill environmental regulations. Furthermore, an environmental effectiveness measure helps the government regulator to verify the rationality of its emissions reduction targets assigned to the thermal power industry. Several newly developed effectiveness measurements based on data envelopment analysis (DEA) were utilized in this study to evaluate the operational and environmental performance of the thermal power industry in China during 2006-2013. Both efficiency and effectiveness were evaluated from the three perspectives of operational, environmental, and joint adjustments to each electricity production system. The operational and environmental performance changes over time were also captured through an effectiveness measure based on the global Malmquist productivity index. Our empirical results indicated that the performance of China's thermal power industry experienced significant progress during the study period and that policies regarding the development and regulation of the thermal power industry yielded the expected effects. However, the emissions reduction targets assigned to China's thermal power industry are loose and conservative. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Comparison of Lives Saved Tool model child mortality estimates against measured data from vector control studies in sub-Saharan Africa

    PubMed Central

    2011-01-01

    Background Insecticide-treated mosquito nets (ITNs) and indoor-residual spraying have been scaled-up across sub-Saharan Africa as part of international efforts to control malaria. These interventions have the potential to significantly impact child survival. The Lives Saved Tool (LiST) was developed to provide national and regional estimates of cause-specific mortality based on the extent of intervention coverage scale-up. We compared the percent reduction in all-cause child mortality estimated by LiST against measured reductions in all-cause child mortality from studies assessing the impact of vector control interventions in Africa. Methods We performed a literature search for appropriate studies and compared reductions in all-cause child mortality estimated by LiST to 4 studies that estimated changes in all-cause child mortality following the scale-up of vector control interventions. The following key parameters measured by each study were applied to available country projections: baseline all-cause child mortality rate, proportion of mortality due to malaria, and population coverage of vector control interventions at baseline and follow-up years. Results The percent reduction in all-cause child mortality estimated by the LiST model fell within the confidence intervals around the measured mortality reductions for all 4 studies. Two of the LiST estimates overestimated the mortality reductions by 6.1 and 4.2 percentage points (33% and 35% relative to the measured estimates), while two underestimated the mortality reductions by 4.7 and 6.2 percentage points (22% and 25% relative to the measured estimates). Conclusions The LiST model did not systematically under- or overestimate the impact of ITNs on all-cause child mortality. These results show the LiST model to perform reasonably well at estimating the effect of vector control scale-up on child mortality when compared against measured data from studies across a range of malaria transmission settings. The LiST model appears to be a useful tool in estimating the potential mortality reduction achieved from scaling-up malaria control interventions. PMID:21501453

  4. Effect of leaded glasses and thyroid shielding on cone beam CT radiation dose in an adult female phantom

    PubMed Central

    Goren, AD; Prins, RD; Dauer, LT; Quinn, B; Al-Najjar, A; Faber, RD; Patchell, G; Branets, I; Colosi, DC

    2013-01-01

    Objectives: This study aims to demonstrate the effectiveness of leaded glasses in reducing the lens of eye dose and of lead thyroid collars in reducing the dose to the thyroid gland of an adult female from dental cone beam CT (CBCT). The effect of collimation on the radiation dose in head organs is also examined. Methods: Dose measurements were conducted by placing optically stimulated luminescent dosemeters in an anthropomorphic female phantom. Eye lens dose was measured by placing a dosemeter on the anterior surface of the phantom eye location. All exposures were performed on one commercially available dental CBCT machine, using selected collimation and exposure techniques. Each scan technique was performed without any lead shielding and then repeated with lead shielding in place. To calculate the percent reduction from lead shielding, the dose measured with lead shielding was divided by the dose measured without lead shielding. The percent reduction from collimation was calculated by comparing the dose measured with collimation to the dose measured without collimation. Results: The dose to the internal eye for one of the scans without leaded glasses or thyroid shield was 0.450 cGy and with glasses and thyroid shield was 0.116 cGy (a 74% reduction). The reduction to the lens of the eye was from 0.396 cGy to 0.153 cGy (a 61% reduction). Without glasses or thyroid shield, the thyroid dose was 0.158 cGy; and when both glasses and shield were used, the thyroid dose was reduced to 0.091 cGy (a 42% reduction). Conclusions: Collimation alone reduced the dose to the brain by up to 91%, with a similar reduction in other organs. Based on these data, leaded glasses, thyroid collars and collimation minimize the dose to organs outside the field of view. PMID:23412460

  5. A Historical Mission in the Accountability Era: A Public HBCU and State Performance Funding

    ERIC Educational Resources Information Center

    Jones, Tiffany

    2016-01-01

    The case study is an analysis of a state performance funding policy at a public historically Black college and university (HBCU). The policy attaches state funding to HBCU performance on measures like graduation rates and equity measures like the reduction in achievement gaps between Black and non-Black students. Participants liked that the policy…

  6. Efficacy of Ginseng Supplements on Fatigue and Physical Performance: a Meta-analysis

    PubMed Central

    2016-01-01

    We conducted a meta-analysis to investigate the efficacy of ginseng supplements on fatigue reduction and physical performance enhancement as reported by randomized controlled trials (RCTs). RCTs that investigated the efficacy of ginseng supplements on fatigue reduction and physical performance enhancement compared with placebos were included. The main outcome measures were fatigue reduction and physical performance enhancement. Out of 155 articles meeting initial criteria, 12 RCTs involving 630 participants (311 participants in the intervention group and 319 participants in the placebo group) were included in the final analysis. In the fixed-effect meta-analysis of four RCTs, there was a statistically significant efficacy of ginseng supplements on fatigue reduction (standardized mean difference, SMD = 0.34; 95% confidence interval [CI] = 0.16 to 0.52). However, ginseng supplements were not associated with physical performance enhancement in the fixed-effect meta-analysis of eight RCTs (SMD = −0.01; 95% CI = −0.29 to 0.27). We found that there was insufficient clinical evidence to support the use of ginseng supplements on reducing fatigue and enhancing physical performance because only few RCTs with a small sample size have been published so far. Further lager RCTs are required to confirm the efficacy of ginseng supplements on fatigue reduction. PMID:27822924

  7. Reliability Testing of NASA Piezocomposite Actuators

    NASA Technical Reports Server (NTRS)

    Wilkie, W.; High, J.; Bockman, J.

    2002-01-01

    NASA Langley Research Center has developed a low-cost piezocomposite actuator which has application for controlling vibrations in large inflatable smart space structures, space telescopes, and high performance aircraft. Tests show the NASA piezocomposite device is capable of producing large, directional, in-plane strains on the order of 2000 parts-per-million peak-to-peak, with no reduction in free-strain performance to 100 million electrical cycles. This paper describes methods, measurements, and preliminary results from our reliability evaluation of the device under externally applied mechanical loads and at various operational temperatures. Tests performed to date show no net reductions in actuation amplitude while the device was moderately loaded through 10 million electrical cycles. Tests were performed at both room temperature and at the maximum operational temperature of the epoxy resin system used in manufacture of the device. Initial indications are that actuator reliability is excellent, with no actuator failures or large net reduction in actuator performance.

  8. Experimental investigation of the noise reduction of supersonic exhaust jets with fluidic inserts

    NASA Astrophysics Data System (ADS)

    Powers, Russell William Walter

    The noise produced by the supersonic, high temperature jets that exhaust from military aircraft is becoming a hazard to naval personnel and a disturbance to communities near military bases. Methods to reduce the noise produced from these jets in a practical full-scale environment are difficult. The development and analysis of distributed nozzle blowing for the reduction of radiated noise from supersonic jets is described. Model scale experiments of jets that simulate the exhaust jets from typical low-bypass ratio military jet aircraft engines during takeoff are performed. Fluidic inserts are created that use distributed blowing in the divergent section of the nozzle to simulate mechanical, hardwall corrugations, while having the advantage of being an active control method. This research focuses on model scale experiments to better understand the fluidic insert noise reduction method. Distributed blowing within the divergent section of the military-style convergent divergent nozzle alters the shock structure of the jet in addition to creating streamwise vorticity for the reduction of mixing noise. Enhancements to the fluidic insert design have been performed along with experiments over a large number of injection parameters and core jet conditions. Primarily military-style round nozzles have been used, with preliminary measurements of hardwall corrugations and fluidic inserts in rectangular nozzle geometries also performed. It has been shown that the noise reduction of the fluidic inserts is most heavily dependent upon the momentum flux ratio between the injector and core jet. Maximum reductions of approximately 5.5 dB OASPL have been observed with practical mass flow rates and injection pressures. The first measurements with fluidic inserts in the presence of a forward flight stream have been performed. Optimal noise reduction occurs at similar injector parameters in the presence of forward flight. Fluidic inserts in the presence of a forward flight stream were observed to reduce the peak mixing noise below the already reduced levels by nearly 4 dB OASP and the broadband shock-associated noise by nearly 3 dB OASP. Unsteady velocity measurements are used to complement acoustic results of jets with fluidic inserts. Measured axial turbulence intensities and mean axial velocity are examined to illuminate the differences in the flow field from jets with fluidic inserts. Comparisons of laser Doppler measurements with RANS CFD simulations are shown with good agreement. Analysis of the effect of spatial turbulence on the measured quantities is performed. Experimental model scale measurements of jets with and without fluidic inserts over a simulated carrier deck are presented. The model carrier environment consists of a ground plane of adjustable distance below the jet, and a simulated jet blast deflector similar to those found in practice. Measurements are performed with far-field microphones, near-field microphones, and unsteady pressure sensors. The constructive and destructive interference that results from the interaction of the direct and reflected sound waves is observed and compared with results from free jets. The noise reduction of fluidic inserts in a realistic carrier deck environment with steering of the "quiet planes" is examined. The overall sound pressure level in heat-simulated jets is reduced by 3-5 dB depending on the specific angle and ground plane height. Jets impinging upon a modeled jet blast deflector are tested in addition to jets solely in the presence of the carrier deck. Observed modifications to the acoustic field from the presence of the jet blast deflector include downstream acoustic shielding and low frequency augmentation. The region of maximum noise radiation for heat-simulated jets from nozzles with fluidic inserts impinging on the jet blast deflector is reduced in overall sound pressure level by 4-7 dB. This region includes areas where aircraft carrier personnel are located. iv.

  9. A novel differential electrochemical mass spectrometry method to determine the product distribution from parasitic Methanol oxidation reaction on oxygen reduction reaction catalysts

    NASA Astrophysics Data System (ADS)

    Jurzinsky, Tilman; Kurzhals, Philipp; Cremers, Carsten

    2018-06-01

    The oxygen reduction reaction is in research focus since several decades due to its importance for the overall fuel cell performance. In direct methanol fuel cells, the crossover of methanol and its subsequent parasitic oxidation are main issues when it comes to preventing fuel cell performance losses. In this work, we present a novel differential electrochemical mass spectrometry method to evaluate oxygen reduction reaction catalysts on their tolerance to methanol being present at the cathode. Besides this, the setup allows to measure under more realistic fuel cell conditions than typical rotating disc electrode measurements, because the oxygen reduction reaction is evaluated in gaseous phase and a gas diffusion electrode is used as working electrode. Due to the new method, it was possible to investigate the oxygen reduction reaction on two commonly used catalysts (Pt/C and Pt3Co/C) in absence and presence of methanol. It was found, that Pt3Co/C is less prone to parasitic current losses due to methanol oxidation reaction. By connecting a mass spectrometer to the electrochemical cell, the new method allows to determine the products formed on the catalysts due to parasitic methanol electrooxidation.

  10. Uniformity index measurement technology using thermocouples to improve performance in urea-selective catalytic reduction systems

    NASA Astrophysics Data System (ADS)

    Park, Sangki; Oh, Jungmo

    2018-05-01

    The current commonly used nitrogen oxides (NOx) emission reduction techniques employ hydrocarbons (HCs), urea solutions, and exhaust gas emissions as the reductants. Two of the primary denitrification NOx (DeNOx) catalyst systems are the HC-lean NOx trap (HC-LNT) catalyst and urea-selective catalytic reduction (urea-SCR) catalyst. The secondary injection method depends on the type of injector, injection pressure, atomization, and spraying technique. In addition, the catalyst reaction efficiency is directly affected by the distribution of injectors; hence, the uniformity index (UI) of the reductant is very important and is the basis for system optimization. The UI of the reductant is an indicator of the NOx conversion efficiency (NCE), and good UI values can reduce the need for a catalyst. Therefore, improving the UI can reduce the cost of producing a catalytic converter, which are expensive due to the high prices of the precious metals contained therein. Accordingly, measurement of the UI is an important process in the development of catalytic systems. Two of the commonly used methods for measuring the reductant UI are (i) measuring the exhaust emissions at many points located upstream/downstream of the catalytic converter and (ii) acquisition of a reductant distribution image on a section of the exhaust pipe upstream of the catalytic converter. The purpose of this study is to develop a system and measurement algorithms to measure the exothermic response distribution in the exhaust gas as the reductant passes through the catalytic converter of the SCR catalyst system using a set of thermocouples downstream of the SCR catalyst. The system is used to measure the reductant UI, which is applied in real-time to the actual SCR system, and the results are compared for various types of mixtures for various engine operating conditions and mixer types in terms of NCE.

  11. Quantitative evaluation of photoplethysmographic artifact reduction for pulse oximetry

    NASA Astrophysics Data System (ADS)

    Hayes, Matthew J.; Smith, Peter R.

    1999-01-01

    Motion artefact corruption of pulse oximeter output, causing both measurement inaccuracies and false alarm conditions, is a primary restriction in the current clinical practice and future applications of this useful technique. Artefact reduction in photoplethysmography (PPG), and therefore by application in pulse oximetry, is demonstrated using a novel non-linear methodology recently proposed by the authors. The significance of these processed PPG signals for pulse oximetry measurement is discussed, with particular attention to the normalization inherent in the artefact reduction process. Quantitative experimental investigation of the performance of PPG artefact reduction is then utilized to evaluate this technology for application to pulse oximetry. While the successfully demonstrated reduction of severe artefacts may widen the applicability of all PPG technologies and decrease the occurrence of pulse oximeter false alarms, the observed reduction of slight artefacts suggests that many such effects may go unnoticed in clinical practice. The signal processing and output averaging used in most commercial oximeters can incorporate these artefact errors into the output, while masking the true PPG signal corruption. It is therefore suggested that PPG artefact reduction should be incorporated into conventional pulse oximetry measurement, even in the absence of end-user artefact problems.

  12. Comparison of Tone Mode Measurements for a Forward Swept and Baseline Rotor Fan

    NASA Technical Reports Server (NTRS)

    Heidelberg, Laurence J.

    2003-01-01

    A forward swept fan, designated the Quite High Speed Fan (QHSF), was tested in the NASA Glenn 9- by 15-foot Low Speed Wind Tunnel to investigate its noise reduction relative to a baseline fan of the same aerodynamic performance. The design objective of the QHSF was a 6 dB reduction in Effective Perceived Noise Level relative to the baseline fan at the takeoff condition. The design noise reduction was to be a result of lower levels of multiple pure tone noise due to the forward swept rotor, and lower rotor/stator interaction tone noise from a leaned stator. Although the design 6 dB reduction was observed in far-field measurements, the induct mode measurements revealed the reasons for goals. All of the noise reduction was from the blade passing tone and its harmonics and most of this was unexpectedly from rotor/strut interaction modes. The reason for large differences in rotor/strut noise sources could not be determined with certainty. The reductions in the multiple pure tone noise for the forward swept rotor were not observed. this reduction were not the ones related to the design

  13. The effect of multi-channel wide dynamic range compression, noise reduction, and the directional microphone on horizontal localization performance in hearing aid wearers.

    PubMed

    Keidser, Gitte; Rohrseitz, Kristin; Dillon, Harvey; Hamacher, Volkmar; Carter, Lyndal; Rass, Uwe; Convery, Elizabeth

    2006-10-01

    This study examined the effect that signal processing strategies used in modern hearing aids, such as multi-channel WDRC, noise reduction, and directional microphones have on interaural difference cues and horizontal localization performance relative to linear, time-invariant amplification. Twelve participants were bilaterally fitted with BTE devices. Horizontal localization testing using a 360 degrees loudspeaker array and broadband pulsed pink noise was performed two weeks, and two months, post-fitting. The effect of noise reduction was measured with a constant noise present at 80 degrees azimuth. Data were analysed independently in the left/right and front/back dimension and showed that of the three signal processing strategies, directional microphones had the most significant effect on horizontal localization performance and over time. Specifically, a cardioid microphone could decrease front/back errors over time, whereas left/right errors increased when different microphones were fitted to left and right ears. Front/back confusions were generally prominent. Objective measurements of interaural differences on KEMAR explained significant shifts in left/right errors. In conclusion, there is scope for improving the sense of localization in hearing aid users.

  14. THE MEASUREMENT AND USE OF CONTAMINANT FLUX FOR PERFORMANCE ASSESSMENT OF DNAPL REMEDIATION

    EPA Science Inventory

    A review is presented of both mass flux as a DNAPL remedial performance metric and reduction in mass flux as a remedial performance objective at one or more control planes down gradient of DNAPL source areas. The use of mass flux to assess remedial performance has been proposed ...

  15. Extreme Performance Scalable Operating Systems Final Progress Report (July 1, 2008 - October 31, 2011)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Malony, Allen D; Shende, Sameer

    This is the final progress report for the FastOS (Phase 2) (FastOS-2) project with Argonne National Laboratory and the University of Oregon (UO). The project started at UO on July 1, 2008 and ran until April 30, 2010, at which time a six-month no-cost extension began. The FastOS-2 work at UO delivered excellent results in all research work areas: * scalable parallel monitoring * kernel-level performance measurement * parallel I/0 system measurement * large-scale and hybrid application performance measurement * onlne scalable performance data reduction and analysis * binary instrumentation

  16. Field scale evaluation of spray drift reduction technologies from ground and aerial application systems

    USDA-ARS?s Scientific Manuscript database

    The objective of this work is to evaluate a proposed Test Plan for the validation testing of pesticide spray drift reduction technologies for row and field crops, focusing on the testing of ground and aerial application systems under full-scale field evaluations. The measure of performance for a gi...

  17. Assessment of the Performance Potential of Advanced Subsonic Transport Concepts for NASA's Environmentally Responsible Aviation Project

    NASA Technical Reports Server (NTRS)

    Nickol, Craig L.; Haller, William J.

    2016-01-01

    NASA's Environmentally Responsible Aviation (ERA) project has matured technologies to enable simultaneous reductions in fuel burn, noise, and nitrogen oxide (NOx) emissions for future subsonic commercial transport aircraft. The fuel burn reduction target was a 50% reduction in block fuel burn (relative to a 2005 best-in-class baseline aircraft), utilizing technologies with an estimated Technology Readiness Level (TRL) of 4-6 by 2020. Progress towards this fuel burn reduction target was measured through the conceptual design and analysis of advanced subsonic commercial transport concepts spanning vehicle size classes from regional jet (98 passengers) to very large twin aisle size (400 passengers). Both conventional tube-and-wing (T+W) concepts and unconventional (over-wing-nacelle (OWN), hybrid wing body (HWB), mid-fuselage nacelle (MFN)) concepts were developed. A set of propulsion and airframe technologies were defined and integrated onto these advanced concepts which were then sized to meet the baseline mission requirements. Block fuel burn performance was then estimated, resulting in reductions relative to the 2005 best-in-class baseline performance ranging from 39% to 49%. The advanced single-aisle and large twin aisle T+W concepts had reductions of 43% and 41%, respectively, relative to the 737-800 and 777-200LR aircraft. The single-aisle OWN concept and the large twin aisle class HWB concept had reductions of 45% and 47%, respectively. In addition to their estimated fuel burn reduction performance, these unconventional concepts have the potential to provide significant noise reductions due, in part, to engine shielding provided by the airframe. Finally, all of the advanced concepts also have the potential for significant NOx emissions reductions due to the use of advanced combustor technology. Noise and NOx emissions reduction estimates were also generated for these concepts as part of the ERA project.

  18. An optimization model for regional air pollutants mitigation based on the economic structure adjustment and multiple measures: A case study in Urumqi city, China.

    PubMed

    Sun, Xiaowei; Li, Wei; Xie, Yulei; Huang, Guohe; Dong, Changjuan; Yin, Jianguang

    2016-11-01

    A model based on economic structure adjustment and pollutants mitigation was proposed and applied in Urumqi. Best-worst case analysis and scenarios analysis were performed in the model to guarantee the parameters accuracy, and to analyze the effect of changes of emission reduction styles. Results indicated that pollutant-mitigations of electric power industry, iron and steel industry, and traffic relied mainly on technological transformation measures, engineering transformation measures and structure emission reduction measures, respectively; Pollutant-mitigations of cement industry relied mainly on structure emission reduction measures and technological transformation measures; Pollutant-mitigations of thermal industry relied mainly on the four mitigation measures. They also indicated that structure emission reduction was a better measure for pollutants mitigation of Urumqi. Iron and steel industry contributed greatly in SO2, NOx and PM (particulate matters) emission reduction and should be given special attention in pollutants emission reduction. In addition, the scales of iron and steel industry should be reduced with the decrease of SO2 mitigation amounts. The scales of traffic and electric power industry should be reduced with the decrease of NOx mitigation amounts, and the scales of cement industry and iron and steel industry should be reduced with the decrease of PM mitigation amounts. The study can provide references of pollutants mitigation schemes to decision-makers for regional economic and environmental development in the 12th Five-Year Plan on National Economic and Social Development of Urumqi. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Methods of Constructing a Blended Performance Function Suitable for Formation Flight

    NASA Technical Reports Server (NTRS)

    Ryan, John J.

    2017-01-01

    This paper presents two methods for constructing an approximate performance function of a desired parameter using correlated parameters. The methods are useful when real-time measurements of a desired performance function are not available to applications such as extremum-seeking control systems. The first method approximates an a priori measured or estimated desired performance function by combining real-time measurements of readily available correlated parameters. The parameters are combined using a weighting vector determined from a minimum-squares optimization to form a blended performance function. The blended performance function better matches the desired performance function mini- mum than single-measurement performance functions. The second method expands upon the first by replacing the a priori data with near-real-time measurements of the desired performance function. The resulting blended performance function weighting vector is up- dated when measurements of the desired performance function are available. Both methods are applied to data collected during formation- flight-for-drag-reduction flight experiments.

  20. Errors in laboratory medicine: practical lessons to improve patient safety.

    PubMed

    Howanitz, Peter J

    2005-10-01

    Patient safety is influenced by the frequency and seriousness of errors that occur in the health care system. Error rates in laboratory practices are collected routinely for a variety of performance measures in all clinical pathology laboratories in the United States, but a list of critical performance measures has not yet been recommended. The most extensive databases describing error rates in pathology were developed and are maintained by the College of American Pathologists (CAP). These databases include the CAP's Q-Probes and Q-Tracks programs, which provide information on error rates from more than 130 interlaboratory studies. To define critical performance measures in laboratory medicine, describe error rates of these measures, and provide suggestions to decrease these errors, thereby ultimately improving patient safety. A review of experiences from Q-Probes and Q-Tracks studies supplemented with other studies cited in the literature. Q-Probes studies are carried out as time-limited studies lasting 1 to 4 months and have been conducted since 1989. In contrast, Q-Tracks investigations are ongoing studies performed on a yearly basis and have been conducted only since 1998. Participants from institutions throughout the world simultaneously conducted these studies according to specified scientific designs. The CAP has collected and summarized data for participants about these performance measures, including the significance of errors, the magnitude of error rates, tactics for error reduction, and willingness to implement each of these performance measures. A list of recommended performance measures, the frequency of errors when these performance measures were studied, and suggestions to improve patient safety by reducing these errors. Error rates for preanalytic and postanalytic performance measures were higher than for analytic measures. Eight performance measures were identified, including customer satisfaction, test turnaround times, patient identification, specimen acceptability, proficiency testing, critical value reporting, blood product wastage, and blood culture contamination. Error rate benchmarks for these performance measures were cited and recommendations for improving patient safety presented. Not only has each of the 8 performance measures proven practical, useful, and important for patient care, taken together, they also fulfill regulatory requirements. All laboratories should consider implementing these performance measures and standardizing their own scientific designs, data analysis, and error reduction strategies according to findings from these published studies.

  1. Analytical simulation of SPS system performance, volume 3, phase 3

    NASA Technical Reports Server (NTRS)

    Kantak, A. V.; Lindsey, W. C.

    1980-01-01

    The simulation model for the Solar Power Satellite spaceantenna and the associated system imperfections are described. Overall power transfer efficiency, the key performance issue, is discussed as a function of the system imperfections. Other system performance measures discussed include average power pattern, mean beam gain reduction, and pointing error.

  2. Implementation of a High-Speed FPGA and DSP Based FFT Processor for Improving Strain Demodulation Performance in a Fiber-Optic-Based Sensing System

    NASA Technical Reports Server (NTRS)

    Farley, Douglas L.

    2005-01-01

    NASA's Aviation Safety and Security Program is pursuing research in on-board Structural Health Management (SHM) technologies for purposes of reducing or eliminating aircraft accidents due to system and component failures. Under this program, NASA Langley Research Center (LaRC) is developing a strain-based structural health-monitoring concept that incorporates a fiber optic-based measuring system for acquiring strain values. This fiber optic-based measuring system provides for the distribution of thousands of strain sensors embedded in a network of fiber optic cables. The resolution of strain value at each discrete sensor point requires a computationally demanding data reduction software process that, when hosted on a conventional processor, is not suitable for near real-time measurement. This report describes the development and integration of an alternative computing environment using dedicated computing hardware for performing the data reduction. Performance comparison between the existing and the hardware-based system is presented.

  3. Investigation of Acoustic Fields for the Cassini Spacecraft: Reverberant Versus Launch Environments

    NASA Technical Reports Server (NTRS)

    Hughes, William O.; McNelis, Anne M.; Himelblau, Harry

    2000-01-01

    The characterization and understanding of the acoustic field within a launch vehicle's payload fairing (PLF) is critical to the qualification of a spacecraft and ultimately to the success of its mission. Acoustic measurements taken recently for the Cassini mission have allowed unique opportunities to advance the aerospace industry's knowledge in this field. Prior to its launch, the expected liftoff acoustic environment of the spacecraft was investigated in a full-scale acoustic test of a Titan IV PLF and Cassini simulator in a reverberant test chamber. A major goal of this acoustic ground test was to quantify and verify the noise reduction performance of special barrier blankets that were designed especially to reduce the Cassirii acoustic environment. This paper will describe both the ground test and flight measurements, and compare the Cassini acoustic environment measured during launch with that measured earlier in the ground test. Special emphasis will be given to the noise reduction performance of the barrier blankets and to the acoustic coherence measured within the PLF.

  4. The Influence of Noise Reduction on Speech Intelligibility, Response Times to Speech, and Perceived Listening Effort in Normal-Hearing Listeners.

    PubMed

    van den Tillaart-Haverkate, Maj; de Ronde-Brons, Inge; Dreschler, Wouter A; Houben, Rolph

    2017-01-01

    Single-microphone noise reduction leads to subjective benefit, but not to objective improvements in speech intelligibility. We investigated whether response times (RTs) provide an objective measure of the benefit of noise reduction and whether the effect of noise reduction is reflected in rated listening effort. Twelve normal-hearing participants listened to digit triplets that were either unprocessed or processed with one of two noise-reduction algorithms: an ideal binary mask (IBM) and a more realistic minimum mean square error estimator (MMSE). For each of these three processing conditions, we measured (a) speech intelligibility, (b) RTs on two different tasks (identification of the last digit and arithmetic summation of the first and last digit), and (c) subjective listening effort ratings. All measurements were performed at four signal-to-noise ratios (SNRs): -5, 0, +5, and +∞ dB. Speech intelligibility was high (>97% correct) for all conditions. A significant decrease in response time, relative to the unprocessed condition, was found for both IBM and MMSE for the arithmetic but not the identification task. Listening effort ratings were significantly lower for IBM than for MMSE and unprocessed speech in noise. We conclude that RT for an arithmetic task can provide an objective measure of the benefit of noise reduction. For young normal-hearing listeners, both ideal and realistic noise reduction can reduce RTs at SNRs where speech intelligibility is close to 100%. Ideal noise reduction can also reduce perceived listening effort.

  5. Voltage-induced reduction of graphene oxide

    NASA Astrophysics Data System (ADS)

    Faucett, Austin C.

    Graphene Oxide (GO) is being widely researched as a precursor for the mass production of graphene, and as a versatile material in its own right for flexible electronics, chemical sensors, and energy harvesting applications. Reduction of GO, an electrically insulating material, into reduced graphene oxide (rGO) restores electrical conductivity via removal of oxygen-containing functional groups. Here, a reduction method using an applied electrical bias, known as voltage-induced reduction, is explored. Voltage-induced reduction can be performed under ambient conditions and avoids the use of hazardous chemicals or high temperatures common with standard methods, but little is known about the reduction mechanisms and the quality of rGO produced with this method. This work performs extensive structural and electrical characterization of voltage-reduced GO (V-rGO) and shows that it is competitive with standard methods. Beyond its potential use as a facile and eco-friendly processing approach, V-rGO reduction also offers record high-resolution patterning capabilities. In this work, the spatial resolution limits of voltage-induced reduction, performed using a conductive atomic force microscope probe, are explored. It is shown that arbitrary V-rGO conductive features can be patterned into insulating GO with nanoscale resolution. The localization of voltage-induced reduction to length scales < 10 nm allows studies of reduction reaction kinetics, using electrical current obtained in-situ, with statistical robustness. Methods for patterning V-rGO nanoribbons are then developed. After presenting sub-10nm patterning of V-rGO nanoribbons in GO single sheets and films, the performance of V-rGO nanoribbon field effect transistors (FETs) are demonstrated. Preliminary measurements show an increase in electrical current on/off ratios as compared to large-area rGO FETs, indicating transport gap modulation that is possibly due to quantum confinement effects.

  6. Gamma model and its analysis for phase measuring profilometry.

    PubMed

    Liu, Kai; Wang, Yongchang; Lau, Daniel L; Hao, Qi; Hassebrook, Laurence G

    2010-03-01

    Phase measuring profilometry is a method of structured light illumination whose three-dimensional reconstructions are susceptible to error from nonunitary gamma in the associated optical devices. While the effects of this distortion diminish with an increasing number of employed phase-shifted patterns, gamma distortion may be unavoidable in real-time systems where the number of projected patterns is limited by the presence of target motion. A mathematical model is developed for predicting the effects of nonunitary gamma on phase measuring profilometry, while also introducing an accurate gamma calibration method and two strategies for minimizing gamma's effect on phase determination. These phase correction strategies include phase corrections with and without gamma calibration. With the reduction in noise, for three-step phase measuring profilometry, analysis of the root mean squared error of the corrected phase will show a 60x reduction in phase error when the proposed gamma calibration is performed versus 33x reduction without calibration.

  7. Cost assessment and ecological effectiveness of nutrient reduction options for mitigating Phaeocystis colony blooms in the Southern North Sea: an integrated modeling approach.

    PubMed

    Lancelot, Christiane; Thieu, Vincent; Polard, Audrey; Garnier, Josette; Billen, Gilles; Hecq, Walter; Gypens, Nathalie

    2011-05-01

    Nutrient reduction measures have been already taken by wealthier countries to decrease nutrient loads to coastal waters, in most cases however, prior to having properly assessed their ecological effectiveness and their economic costs. In this paper we describe an original integrated impact assessment methodology to estimate the direct cost and the ecological performance of realistic nutrient reduction options to be applied in the Southern North Sea watershed to decrease eutrophication, visible as Phaeocystis blooms and foam deposits on the beaches. The mathematical tool couples the idealized biogeochemical GIS-based model of the river system (SENEQUE-RIVERSTRAHLER) implemented in the Eastern Channel/Southern North Sea watershed to the biogeochemical MIRO model describing Phaeocystis blooms in the marine domain. Model simulations explore how nutrient reduction options regarding diffuse and/or point sources in the watershed would affect the Phaeocystis colony spreading in the coastal area. The reference and prospective simulations are performed for the year 2000 characterized by mean meteorological conditions, and nutrient reduction scenarios include and compare upgrading of wastewater treatment plants and changes in agricultural practices including an idealized shift towards organic farming. A direct cost assessment is performed for each realistic nutrient reduction scenario. Further the reduction obtained for Phaeocystis blooms is assessed by comparison with ecological indicators (bloom magnitude and duration) and the cost for reducing foam events on the beaches is estimated. Uncertainty brought by the added effect of meteorological conditions (rainfall) on coastal eutrophication is discussed. It is concluded that the reduction obtained by implementing realistic environmental measures on the short-term is costly and insufficient to restore well-balanced nutrient conditions in the coastal area while the replacement of conventional agriculture by organic farming might be an option to consider in the nearby future. Copyright © 2011 Elsevier B.V. All rights reserved.

  8. A system dynamics-based environmental performance simulation of construction waste reduction management in China.

    PubMed

    Ding, Zhikun; Yi, Guizhen; Tam, Vivian W Y; Huang, Tengyue

    2016-05-01

    A huge amount of construction waste has been generated from increasingly higher number of construction activities than in the past, which has significant negative impacts on the environment if they are not properly managed. Therefore, effective construction waste management is of primary importance for future sustainable development. Based on the theory of planned behaviors, this paper develops a system dynamic model of construction waste reduction management at the construction phase to simulate the environmental benefits of construction waste reduction management. The application of the proposed model is shown using a case study in Shenzhen, China. Vensim is applied to simulate and analyze the model. The simulation results indicate that source reduction is an effective waste reduction measure which can reduce 27.05% of the total waste generation. Sorting behaviors are a premise for improving the construction waste recycling and reuse rates which account for 15.49% of the total waste generated. The environmental benefits of source reduction outweigh those of sorting behaviors. Therefore, to achieve better environmental performance of the construction waste reduction management, attention should be paid to source reduction such as low waste technologies and on-site management performance. In the meantime, sorting behaviors encouragement such as improving stakeholders' waste awareness, refining regulations, strengthening government supervision and controlling illegal dumping should be emphasized. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. REPEATED INHALATION OF TOLUENE BY RATS PERFORMING A SIGNAL DETECTION TASK LEADS TO BEHVIORAL TOLERANCE ON SOME PERFORMANCE MEASURES.

    EPA Science Inventory

    Previous work showed that trichloroethylene (TCE) impairs sustained attention as evidenced by a reduction in accuracy and elevation of response latencies in rats trained to perform a visual signal detection task (SDT). This work also showed that these effects abate during repeat...

  10. F/A-18 Performance Benefits Measured During the Autonomous Formation Flight Project

    NASA Technical Reports Server (NTRS)

    Vachon, M. Jake; Ray, Ronald J.; Walsh, Kevin R.; Ennix, Kimberly

    2003-01-01

    The Autonomous Formation Flight (AFF) project at the NASA Dryden Flight Research Center (Edwards, California) investigated performance benefits resulting from formation flight, such as reduced aerodynamic drag and fuel consumption. To obtain data on performance benefits, a trailing F/A-18 airplane flew within the wing tip-shed vortex of a leading F/A-18 airplane. The pilot of the trail airplane used advanced station-keeping technology to aid in positioning the trail airplane at precise locations behind the lead airplane. The specially instrumented trail airplane was able to obtain accurate fuel flow measurements and to calculate engine thrust and vehicle drag. A maneuver technique developed for this test provided a direct comparison of performance values while flying in and out of the vortex. Based on performance within the vortex as a function of changes in vertical, lateral, and longitudinal positioning, these tests explored design-drivers for autonomous stationkeeping control systems. Observations showed significant performance improvements over a large range of trail positions tested. Calculations revealed maximum drag reductions of over 20 percent, and demonstrated maximum reductions in fuel flow of just over 18 percent.

  11. Field Test Evaluation of Conservation Retrofits of Low-Income, Single-Family Buildings in Wisconsin: Blower-Door-Directed Infiltration Reduction Procedure, Field Test Implementation and Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gettings, M.B.

    A blower-door-directed infiltration retrofit procedure was field tested on 18 homes in south central Wisconsin. The procedure, developed by the Wisconsin Energy Conservation Corporation, includes recommended retrofit techniques as well as criteria for estimating the amount of cost-effective work to be performed on a house. A recommended expenditure level and target air leakage reduction, in air changes per hour at 50 Pascal (ACH50), are determined from the initial leakage rate measured. The procedure produced an average 16% reduction in air leakage rate. For the 7 houses recommended for retrofit, 89% of the targeted reductions were accomplished with 76% of themore » recommended expenditures. The average cost of retrofits per house was reduced by a factor of four compared with previous programs. The average payback period for recommended retrofits was 4.4 years, based on predicted energy savings computed from achieved air leakage reductions. Although exceptions occurred, the procedure's 8 ACH50 minimum initial leakage rate for advising retrofits to be performed appeared a good choice, based on cost-effective air leakage reduction. Houses with initial rates of 7 ACH50 or below consistently required substantially higher costs to achieve significant air leakage reductions. No statistically significant average annual energy savings was detected as a result of the infiltration retrofits. Average measured savings were -27 therm per year, indicating an increase in energy use, with a 90% confidence interval of 36 therm. Measured savings for individual houses varied widely in both positive and negative directions, indicating that factors not considered affected the results. Large individual confidence intervals indicate a need to increase the accuracy of such measurements as well as understand the factors which may cause such disparity. Recommendations for the procedure include more extensive training of retrofit crews, checks for minimum air exchange rates to insure air quality, and addition of the basic cost of determining the initial leakage rate to the recommended expenditure level. Recommendations for the field test of the procedure include increasing the number of houses in the sample, more timely examination of metered data to detect anomalies, and the monitoring of indoor air temperature. Though not appropriate in a field test of a procedure, further investigation into the effects of air leakage rate reductions on heating loads needs to be performed.« less

  12. Measurement of menadione in urine by HPLC

    USDA-ARS?s Scientific Manuscript database

    Mammals convert phylloquinone to MK-4, with menadione as a possible intermediate. We developed and validated a method measuring urinary menadione. A high performance liquid chromatography (HPLC) method with a C30 column, fluorescence detection and post-column zinc reduction was developed. The mobile...

  13. A Performance and Plume Comparison of Xenon and Krypton Propellant on the SPT-100

    DTIC Science & Technology

    2012-07-02

    HET (1.35 kW), performance measurements were made using an inverted pendulum thrust stand. The plume was also characterized by a Faraday probe and RPA...performance reduction for the case of the flight model SPT-100 HET (1.35 kW), per- formance measurements were made using an inverted pendulum thrust stand...where high thrust at reduced specific impulse is advantageous, such as orbit raising missions. Bismuth’s main drawback is that the metal must be

  14. Recommended Practices for Measurement of Gas Path Pressures and Temperatures for Performance Assessment of Aircraft Turbine Engines and Components (Les Methodes Recommandees pour la Mesure de la Pression et de la Temperature de la Veine Gazeuse en Vue de l’Evaluation des Performances des Turbines Aeronautiques et de leurs Composants

    DTIC Science & Technology

    1990-06-01

    reduction software , prior to converting all remaining test which requires internal compensation. T he r sidual effect is pressures to engineering units...Reduction Conversion of Millivolts to Engineering Units. Carrying out numerical integrations to obtain area and mass weighted averages for various...Performance Assessment of Aircraft Turbine Engines and Components (Les MWthodes Recommande’es pour la Mesure de la Pression et de ]a Temperature de la

  15. Breakfast skipping in prepubertal obese children: hormonal, metabolic and cognitive consequences.

    PubMed

    Maffeis, C; Fornari, E; Surano, M G; Comencini, E; Corradi, M; Tommasi, M; Fasan, I; Cortese, S

    2012-03-01

    Skipping breakfast influences cognitive performance. The aim of our study was to investigate the relationship between the variation of hormonal and metabolic postprandial parameters induced by breakfast consumption or fasting and cognitive performance in obese children. Cross-sectional study for repeated measures. Memory and attention assessment tests, hormones and nutrient oxidation were measured before and after consuming breakfast vs fasting in 10 prepubertal obese children. Fasting induced a significant (P<0.05) increase of the Overall Index of the Continuous Performance Test II (a global index of inattention) and the Test of Memory and Learning Word Selective Reminding (a test of verbal memory), whereas no changes were found after breakfast. Fasting was associated with a reduction of insulin and an increase in glucagon, with no changes in glucose. The increase in inattention was associated with a reduction of carbohydrate oxidation (ρ=-0.66, P<0.05). We found no difference in the area under the curve of peptide YY and glucagon-like peptide-1 after breakfast or fasting, whereas Ghrelin was significantly lower. No association between postprandial hormone variation and cognitive performance was found. Attention and visual memory performance in the morning were reduced when the children skipped breakfast. No association was found with hormones or metabolic changes, but we did find an association with a reduction of carbohydrate oxidation. Nevertheless, these preliminary findings need confirmation in larger sample size.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Okihira, K.; Hara, H.; Ikeda, N.

    MHI have supplied several 9-cell cavities for STF (R&D of ILC project at KEK) and have been considering production method for stable quality and cost reduction, seamless dumb-bell cavity was one of them. We had fabricated a 2 cell seamless dumb-bell cavity for cost reduction and measured RF performance in collaboration with JLab, KEK and MHI. Surface treatment recipe for ILC was applied for MHI 2-cell cavity and vertical test was performed at JLab. The cavity reached Eacc=32.4MV/m after BCP and EP. Details of the result are reported.

  17. Effective dimension reduction for sparse functional data

    PubMed Central

    YAO, F.; LEI, E.; WU, Y.

    2015-01-01

    Summary We propose a method of effective dimension reduction for functional data, emphasizing the sparse design where one observes only a few noisy and irregular measurements for some or all of the subjects. The proposed method borrows strength across the entire sample and provides a way to characterize the effective dimension reduction space, via functional cumulative slicing. Our theoretical study reveals a bias-variance trade-off associated with the regularizing truncation and decaying structures of the predictor process and the effective dimension reduction space. A simulation study and an application illustrate the superior finite-sample performance of the method. PMID:26566293

  18. Particle Aggregation During Fe(III) Bioreduction in Nontronite

    NASA Astrophysics Data System (ADS)

    Jaisi, D. P.; Dong, H.; Hi, Z.; Kim, J.

    2005-12-01

    This study was performed to evaluate the rate and mechanism of particle aggregation during bacterial Fe (III) reduction in different size fractions of nontronite and to investigate the role of different factors contributing to particle aggregation. To achieve this goal, microbial Fe(III) reduction experiments were performed with lactate as an electron donor, Fe(III) in nontronite as an electron acceptor, and AQDS as an electron shuttle in bicarbonate buffer using Shewanella putrefaceins CN32. These experiments were performed with and without Na- pyrophosphate as a dispersant in four size fractions of nontronite (0.12-0.22, 0.41-0.69, 0.73-0.96 and 1.42-1.8 mm). The rate of nontronite aggregation during the Fe(III) bioreduction was measured by analyzing particle size distribution using photon correlation spectroscopy (PCS) and SEM images analysis. Similarly, the changes in particle morphology during particle aggregation were determined by analyses of SEM images. Changes in particle surface charge were measured with electrophoretic mobility analyzer. The protein and carbohydrate fraction of EPS produced by cells during Fe(III) bioreduction was measured using Bradford and phenol-sulfuric acid extraction method, respectively. In the presence of the dispersant, the extent of Fe(III) bioreduction was 11.5-12.2% within the first 56 hours of the experiment. There was no measurable particle aggregation in control experiments. The PCS measurements showed that the increase in the effective diameter (95% percentile) was by a factor of 3.1 and 1.9 for particle size of 0.12-0.22 mm and 1.42-1.80 mm, respectively. The SEM image analyses also gave the similar magnitude of increase in particle size. In the absence of the dispersant, the extent of Fe(III) bioreduction was 13.4-14.5% in 56 hours of the experiment. The rate of aggregation was higher than that in the presence of the dispersant. The increase in the effective diameter (95% percentile) was by a factor of 13.6 and 4.1 for the particles size of 0.12-0.22 and 1.42-1.8 mm, respectively. The particle aggregation was limited in control experiment to the factor of 2.8 and 2.1 for these two size fractions, respectively. The measured electrophoretic mobility decreased with increase in the extent of bioreduction and aggregation, but the rate of decrease was greatest in the finest size fraction. The EPS measurements showed the increase in the carbohydrate and protein fractions as a result of bioreduction. Separate experiments were performed to understand the relative contribution of Fe(III) reduction and EPS production in controlling nontronite particle aggregation The rate of particle aggregation was measured for nontronite that was chemically pre-reduced by dithionite to various extents, both with and without addition of dextran, a neutral and pure EPS. The aggregation rate was greater in the nontronite that were pre-reduced to a higher extent than those with a lower extent of reduction. The relative contribution to particle aggregation due to Fe(III) reduction and polysaccharide bridging was about 4:1. However, in the real system where bacterial cells are involved, and amount of EPS production and extent of Fe(III) bioreduction increase with time, the relative contribution may be different than in this simple system. In summary, we conclude that both Fe(III) reduction and microbial production of EPS contribute to the observed nontronite particle aggregation with Fe(III) reduction playing more dominant role.

  19. Development and validation of the Alzheimer's prevention beliefs measure in a multi-ethnic cohort-a behavioral theory approach.

    PubMed

    Seifan, Alon; Ganzer, Christine A; Vermeylen, Francoise; Parry, Stephen; Zhu, Jifeng; Lyons, Abigail; Isaacson, Richard; Kim, Sarang

    2017-12-01

    Understanding health beliefs and how they influence willingness will enable the development of targeted curricula that maximize public engagement in Alzheimer's disease (AD) risk reduction behaviors. Literature on behavioral theory and community input was used to develop and validate a health beliefs survey about AD risk reduction among 428 community-dwelling adults. Principal component analysis was performed to assess internal consistency. Linear regression was performed to identify key predictors of Willingness to engage in AD risk reduction behaviors. The measure as well as the individual scales (Benefits, Barriers, Severity, Susceptibility and Social Norm) were found to be internally consistent. Overall, as Benefits and Barriers scores increased, Willingness scores also increased. Those without prior AD experience or family history had lower willingness scores. Finally, we observed an interaction between age and norms, suggesting that social factors related to AD prevention may differentially affect people of different ages. The Alzheimer Prevention Beliefs Measure provides assessment of several health belief factors related to AD prevention. Age, Family History, Logistical Barriers and total Benefits are significant determinants of willingness to engage in AD risk reduction behaviors, such as seeing a doctor or making a lifestyle change. © The Author 2017. Published by Oxford University Press on behalf of Faculty of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  20. Weight reduction does not induce an undesirable decrease in muscle mass, muscle strength, or physical performance in men with obesity: a pilot study.

    PubMed

    Kim, Bokun; Tsujimoto, Takehiko; So, Rina; Zhao, Xiaoguang; Oh, Sechang; Tanaka, Kiyoji

    2017-12-31

    To date, there have been no reports on whether weight reduction causes decreases in muscle mass, muscle strength, or physical performance that could lead to health problems. Thus, in this pilot study, we investigated the appropriateness of the changes in muscle mass, muscle strength and physical performance after weight reduction. Obese men who completed a weight reduction program to decrease and maintain a body mass index (BMI) of less than 25 kg/m2 for one year were recruited for the study. One year after the completion of a weight reduction program, the participants' muscle mass, muscle strength, and physical performance were compared with those in a reference group composed of individuals whose BMI was less than 25 kg/m2. Whole-body scanning was performed using dual-energy X-ray absorptiometry to analyze muscle mass. Handgrip strength and knee extensor strength were measured to evaluate arm and leg muscle strength, respectively. For physical performance, a jump test was employed. The results showed that the biceps, triceps, subscapular, and suprailiac areas of professional fashion models were significantly thinner than those of women in general (p<.001), and that their waist size was also significantly smaller (p<.001). However, hip circumference showed no significant difference. Body mass index, waist-to-hip ratio, and body fat (%) in professional fashion models were significantly lower than those in women in general (p<.001), while the body density in professional fashion models was significantly greater (p<0.001). Weight reduction participants showed an average reduction in body weight of -16.47%. Normalized arm muscle mass and handgrip strength were significantly greater in the weight reduction group than in the reference group; however, no significant differences were detected between the two groups with respect to the other variables. After one year, there were no significant differences between the two groups. ©2017 The Korean Society for Exercise Nutrition

  1. A longitudinal investigation of work environment stressors on the performance and wellbeing of office workers.

    PubMed

    Lamb, S; Kwok, K C S

    2016-01-01

    This study uses a longitudinal within-subjects design to investigate the effects of inadequate Indoor Environmental Quality (IEQ) on work performance and wellbeing in a sample of 114 office workers over a period of 8 months. Participants completed a total of 2261 online surveys measuring perceived thermal comfort, lighting comfort and noise annoyance, measures of work performance, and individual state factors underlying performance and wellbeing. Characterising inadequate aspects of IEQ as environmental stressors, these stress factors can significantly reduce self-reported work performance and objectively measured cognitive performance by between 2.4% and 5.8% in most situations, and by up to 14.8% in rare cases. Environmental stressors act indirectly on work performance by reducing state variables, motivation, tiredness, and distractibility, which support high-functioning work performance. Exposure to environmental stress appears to erode individuals' resilience, or ability to cope with additional task demands. These results indicate that environmental stress reduces not only the cognitive capacity for work, but the rate of work (i.e. by reducing motivation). Increasing the number of individual stress factors is associated with a near linear reduction in work performance indicating that environmental stress factors are additive, not multiplicative. Environmental stressors reduce occupant wellbeing (mood, headaches, and feeling 'off') causing indirect reductions in work performance. Improving IEQ will likely produce small but pervasive increases in productivity. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  2. Detailed Project Report and Environmental Assessment on Upper Gordons Creek, Urban Flood Damage Reduction Measures at Hattiesburg, Mississippi.

    DTIC Science & Technology

    1986-09-01

    REDUCTION MEASURES AT HATTIESBURG, MISSISSIPPI US Army Corps SEPTEMBER 1986 of Engineers Mobile District DTIC South Atlantic Division O ELECTE S APR 14S1 87...8. CONTRACT OR GRANT NUMBER(&) U.S. Army Corps of Engineers, Mobile 9. PERFORMING ORGANIZATION NAME AND ADDRESS 10. PROGRAM ELEMENT, PROJECT. TASK U.S...Army Corps of Enineers AREA & WORK UNIT NUMBERS ATTN: SAMPD-FW 1 P.O. Box 2288, Mobile , AL 36628 $1. CONTROLLING OFFICE NAME AND ADDRESS 12. REPORT

  3. Examining the effects of rational emotive behavior therapy on performance outcomes in elite paralympic athletes.

    PubMed

    Wood, A G; Barker, J B; Turner, M J; Sheffield, D

    2018-01-01

    Traditionally a psychotherapeutic intervention, rational emotive behavior therapy (REBT) is receiving increasing attention within the extant literature as an intervention to enhance the athletic performance and psychological well-being of competitive athletes. Whilst the benefits of REBT on psychological health are established, less is understood about the effects on athletic performance. This study aimed to examine the immediate and maintained effects of REBT on physiological, psychological, and performance outcomes with elite Paralympic athletes. Using a single-case research design, eight athletes recruited from the same Paralympic sport (M=40.12, SD=12.99) received five, one-to-one REBT sessions. Measures of irrational beliefs were collected weekly, whereas the remaining psychological and physiological measures were collected at a pre-, post-, and at a 9-month follow-up time point. Visual and statistical analyzes of the data indicates reductions in irrational beliefs were coupled with reductions in systolic blood pressure indicative of an adaptive physiological response, improved athletic performance during competition simulations, and reductions in avoidance goals. Furthermore, social validation data indicated greater self-awareness, emotional control, and enhanced focus during competition as a result of the REBT intervention. This study contributes to growing literature supporting the efficacy of REBT as an intervention that not only facilitates psychological health but also enhances athletic performance. Results are discussed with reference to theory, limitations, and future recommendations. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. A Fourier dimensionality reduction model for big data interferometric imaging

    NASA Astrophysics Data System (ADS)

    Vijay Kartik, S.; Carrillo, Rafael E.; Thiran, Jean-Philippe; Wiaux, Yves

    2017-06-01

    Data dimensionality reduction in radio interferometry can provide savings of computational resources for image reconstruction through reduced memory footprints and lighter computations per iteration, which is important for the scalability of imaging methods to the big data setting of the next-generation telescopes. This article sheds new light on dimensionality reduction from the perspective of the compressed sensing theory and studies its interplay with imaging algorithms designed in the context of convex optimization. We propose a post-gridding linear data embedding to the space spanned by the left singular vectors of the measurement operator, providing a dimensionality reduction below image size. This embedding preserves the null space of the measurement operator and hence its sampling properties are also preserved in light of the compressed sensing theory. We show that this can be approximated by first computing the dirty image and then applying a weighted subsampled discrete Fourier transform to obtain the final reduced data vector. This Fourier dimensionality reduction model ensures a fast implementation of the full measurement operator, essential for any iterative image reconstruction method. The proposed reduction also preserves the independent and identically distributed Gaussian properties of the original measurement noise. For convex optimization-based imaging algorithms, this is key to justify the use of the standard ℓ2-norm as the data fidelity term. Our simulations confirm that this dimensionality reduction approach can be leveraged by convex optimization algorithms with no loss in imaging quality relative to reconstructing the image from the complete visibility data set. Reconstruction results in simulation settings with no direction dependent effects or calibration errors show promising performance of the proposed dimensionality reduction. Further tests on real data are planned as an extension of the current work. matlab code implementing the proposed reduction method is available on GitHub.

  5. Digitally enhanced homodyne interferometry.

    PubMed

    Sutton, Andrew J; Gerberding, Oliver; Heinzel, Gerhard; Shaddock, Daniel A

    2012-09-24

    We present two variations of a novel interferometry technique capable of simultaneously measuring multiple targets with high sensitivity. The technique performs a homodyne phase measurement by application of a four point phase shifting algorithm, with pseudo-random switching between points to allow multiplexed measurement based upon propagation delay alone. By multiplexing measurements and shifting complexity into signal processing, both variants realise significant complexity reductions over comparable methods. The first variant performs a typical coherent detection with a dedicated reference field and achieves a displacement noise floor 0.8 pm/√Hz above 50 Hz. The second allows for removal of the dedicated reference, resulting in further simplifications and improved low frequency performance with a 1 pm/√Hz noise floor measured down to 20 Hz. These results represent the most sensitive measurement performed using this style of interferometry whilst simultaneously reducing the electro-optic footprint.

  6. Contactless Abdominal Fat Reduction With Selective RF™ Evaluated by Magnetic Resonance Imaging (MRI): Case Study.

    PubMed

    Downie, Jeanine; Kaspar, Miroslav

    2016-04-01

    Noninvasive body shaping methods seem to be an ascending part of the aesthetics market. As a result, the pressure to develop reliable methods for the collection and presentation of their results has also increased. The most used techniques currently include ultrasound measurements of fat thickness in the treated area, caliper measurements, bioimpedance-based scale measurements or circumferential tape measurements. Although these are the most used techniques, almost all of them have some limitations in reproducibility and/or accuracy. This study shows Magnetic Resonance Imaging (MRI) as the new method for the presentation of results in the body shaping industry. Six subjects were treated by a contactless selective radiofrequency device (BTL Vanquish ME, BTL Industries Inc., Boston, MA). The MRI fat thickness was measured at the baseline and at 4-weeks following the treatment. In addition to MRI images and measurements, digital photographs and anthropometric evaluations such as weight, abdominal circumference, and caliper fat thickness measurements were recorded. Abdominal fat thickness measurements from the MRI were performed from the same slices determined by the same tissue artefacts. The MRI fat thickness difference between the baseline measurement and follow up visit showed an average reduction of 5.36 mm as calculated from the data of 5 subjects. One subject dropped out of study due to non-study related issues. The results were statistically significant based on the Student's T-test evaluation. Magnetic resonance imaging abdominal fat thickness measurements seems to be the best method for the evaluation of fat thickness reduction after non-invasive body shaping treatments. In this study, this method shows average fat thickness reduction of 5.36 mm while the weight of the subjects didn't change significantly. A large spot size measuring 1317 cm(2) (204 square inches) covers the abdomen flank to flank. The average thickness of 5.36 mm of the fat layer reduced under the applicator translates into significant cumulative circumferential reduction. The reduction was not related with dieting.

  7. Acoustic tests of duct-burning turbofan jet noise simulation

    NASA Technical Reports Server (NTRS)

    Knott, P. R.; Stringas, E. J.; Brausch, J. F.; Staid, P. S.; Heck, P. H.; Latham, D.

    1978-01-01

    The results of a static acoustic and aerodynamic performance, model-scale test program on coannular unsuppressed and multielement fan suppressed nozzle configurations are summarized. The results of the static acoustic tests show a very beneficial interaction effect. When the measured noise levels were compared with the predicted noise levels of two independent but equivalent conical nozzle flow streams, noise reductions for the unsuppressed coannular nozzles were of the order of 10 PNdB; high levels of suppression (8 PNdB) were still maintained even when only a small amount of core stream flow was used. The multielement fan suppressed coannular nozzle tests showed 15 PNdB noise reductions and up to 18 PNdB noise reductions when a treated ejector was added. The static aerodynamic performance tests showed that the unsuppressed coannular plug nozzles obtained gross thrust coefficients of 0.972, with 1.2 to 1.7 percent lower levels for the multielement fan-suppressed coannular flow nozzles. For the first time anywhere, laser velocimeter velocity profile measurements were made on these types of nozzle configurations and with supersonic heated flow conditions. Measurements showed that a very rapid decay in the mean velocity occurs for the nozzle tested.

  8. Measurement of radiation damage of water-based liquid scintillator and liquid scintillator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bignell, L. J.; Diwan, M. V.; Hans, S.

    2015-10-19

    Liquid scintillating phantoms have been proposed as a means to perform real-time 3D dosimetry for proton therapy treatment plan verification. We have studied what effect radiation damage to the scintillator will have upon this application. We have performed measurements of the degradation of the light yield and optical attenuation length of liquid scintillator and water-based liquid scintillator after irradiation by 201 MeV proton beams that deposited doses of approximately 52 Gy, 300 Gy, and 800 Gy in the scintillator. Liquid scintillator and water-based liquid scintillator (composed of 5% scintillating phase) exhibit light yield reductions of 1.74 ± 0.55 % andmore » 1.31 ± 0.59 % after ≈ 800 Gy of proton dose, respectively. Some increased optical attenuation was observed in the irradiated samples, the measured reduction to the light yield is also due to damage to the scintillation light production. Based on our results and conservative estimates of the expected dose in a clinical context, a scintillating phantom used for proton therapy treatment plan verification would exhibit a systematic light yield reduction of approximately 0.1% after a year of operation.« less

  9. Acoustic and Auditory Perception Effects of the Voice Therapy Technique Finger Kazoo in Adult Women.

    PubMed

    Christmann, Mara Keli; Cielo, Carla Aparecida

    2017-05-01

    This study aimed to verify and to correlate acoustic and auditory-perceptual measures of glottic source after the performance of finger kazoo (FK) technique. This is an experimental, cross-sectional, and qualitative study. We made an analysis of the vowel [a:] in 46 adult women with neither vocal complaints nor laryngeal alterations, through the Multi-Dimensional Voice Program Advanced and RASATI scale, before and immediately after performing three series of FK and 5 minutes after a period of silence. Kappa, Friedman, Wilcoxon, and Spearman tests were used. We found significant increase in fundamental frequency, reduction of amplitude variation, and degree of sub-harmonics immediately after performing FK. Positive correlations were measures of frequency and its perturbation, measures of amplitude, of soft phonation index, of degree and number of unvoiced segments with aspects of RASATI. Negative correlations were voice turbulence index, measures of frequency and its perturbation, and measures of soft phonation index with aspects of RASATI. There was fundamental frequency increase, within normal limits, and reduction of acoustic measures related to presence of noise and instability. In general, acoustic measures, suggestive of noise and instability, were reduced according to the decrease of perceptive-auditory aspects of vocal alteration. It shows that both instruments are complementary and that the acoustic vocal effect was positive. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  10. Measurement of Menadione in urine by HPLC

    USDA-ARS?s Scientific Manuscript database

    Menadione may be an important metabolite of vitamin K that is excreted in urine. A high performance liquid chromatography (HPLC) method with a C30 column, fluorescence detection and post-column zinc reduction was developed to measure menadione in urine. The mobile phase was composed of 95% methanol...

  11. Peak-locking error reduction by birefringent optical diffusers

    NASA Astrophysics Data System (ADS)

    Kislaya, Ankur; Sciacchitano, Andrea

    2018-02-01

    The use of optical diffusers for the reduction of peak-locking errors in particle image velocimetry is investigated. The working principle of the optical diffusers is based on the concept of birefringence, where the incoming rays are subject to different deflections depending on the light direction and polarization. The performances of the diffusers are assessed via wind tunnel measurements in uniform flow and wall-bounded turbulence. Comparison with best-practice image defocusing is also conducted. It is found that the optical diffusers yield an increase of the particle image diameter up to 10 µm in the sensor plane. Comparison with reference measurements showed a reduction of both random and systematic errors by a factor of 3, even at low imaging signal-to-noise ratio.

  12. Design of Miniaturized Double-Negative Material for Specific Absorption Rate Reduction in Human Head

    PubMed Central

    Faruque, Mohammad Rashed Iqbal; Islam, Mohammad Tariqul

    2014-01-01

    In this study, a double-negative triangular metamaterial (TMM) structure, which exhibits a resounding electric response at microwave frequency, was developed by etching two concentric triangular rings of conducting materials. A finite-difference time-domain method in conjunction with the lossy-Drude model was used in this study. Simulations were performed using the CST Microwave Studio. The specific absorption rate (SAR) reduction technique is discussed, and the effects of the position of attachment, the distance, and the size of the metamaterials on the SAR reduction are explored. The performance of the double-negative TMMs in cellular phones was also measured in the cheek and the tilted positions using the COMOSAR system. The TMMs achieved a 52.28% reduction for the 10 g SAR. These results provide a guideline to determine the triangular design of metamaterials with the maximum SAR reducing effect for a mobile phone. PMID:25350398

  13. Design of miniaturized double-negative material for specific absorption rate reduction in human head.

    PubMed

    Faruque, Mohammad Rashed Iqbal; Islam, Mohammad Tariqul

    2014-01-01

    In this study, a double-negative triangular metamaterial (TMM) structure, which exhibits a resounding electric response at microwave frequency, was developed by etching two concentric triangular rings of conducting materials. A finite-difference time-domain method in conjunction with the lossy-Drude model was used in this study. Simulations were performed using the CST Microwave Studio. The specific absorption rate (SAR) reduction technique is discussed, and the effects of the position of attachment, the distance, and the size of the metamaterials on the SAR reduction are explored. The performance of the double-negative TMMs in cellular phones was also measured in the cheek and the tilted positions using the COMOSAR system. The TMMs achieved a 52.28% reduction for the 10 g SAR. These results provide a guideline to determine the triangular design of metamaterials with the maximum SAR reducing effect for a mobile phone.

  14. Applications of laser-induced breakdown spectroscopy in the aluminum electrolysis industry

    NASA Astrophysics Data System (ADS)

    Sun, Lanxiang; Yu, Haibin; Cong, Zhibo; Lu, Hui; Cao, Bin; Zeng, Peng; Dong, Wei; Li, Yang

    2018-04-01

    The industrial aluminum reduction cell is an electrochemistry reactor that operates under high temperatures and corrosive conditions. Monitoring the molten aluminum and electrolyte components is very important for controlling the chemical reaction process. Due to the lack of fast methods to monitor the components, controlling aluminum reduction cells is difficult. In this work, laser-induced breakdown spectroscopy (LIBS) was applied to aluminum electrolysis. A new method for calculating the molecular ratio, which is an important control parameter that represents the acidity of the electrolyte, was proposed. Experiments were first performed on solid electrolyte samples to test the performance of the proposed method. Using this method, the average relative standard deviation (RSD) of the molecular ratio measurement was 0.39%, and the average root mean square error (RMSE) was 0.0236. These results prove that LIBS can accurately measure the molecular ratio. Then, in situ measurements of the molten aluminum and electrolyte were performed in industrial aluminum induction cells using the developed LIBS equipment. The spectra of the molten electrolyte were successfully obtained and were consistent with the spectra of the solid electrolyte.

  15. Associations between early life adversity and executive function in children adopted internationally from orphanages

    PubMed Central

    Hostinar, Camelia E.; Stellern, Sarah A.; Schaefer, Catherine; Carlson, Stephanie M.; Gunnar, Megan R.

    2012-01-01

    Executive function (EF) abilities are increasingly recognized as an important protective factor for children experiencing adversity, promoting better stress and emotion regulation as well as social and academic adjustment. We provide evidence that early life adversity is associated with significant reductions in EF performance on a developmentally sensitive battery of laboratory EF tasks that measured cognitive flexibility, working memory, and inhibitory control. Animal models also suggest that early adversity has a negative impact on the development of prefrontal cortex-based cognitive functions. In this study, we report EF performance 1 y after adoption in 2.5- to 4-y-old children who had experienced institutional care in orphanages overseas compared with a group of age-matched nonadopted children. To our knowledge, this is the youngest age and the soonest after adoption that reduced EF performance has been shown using laboratory measures in this population. EF reductions in performance were significant above and beyond differences in intelligence quotient. Within the adopted sample, current EF was associated with measures of early deprivation after controlling for intelligence quotient, with less time spent in the birth family before placement in an institution and lower quality of physical/social care in institutions predicting poorer performance on the EF battery. PMID:23047689

  16. Associations between early life adversity and executive function in children adopted internationally from orphanages.

    PubMed

    Hostinar, Camelia E; Stellern, Sarah A; Schaefer, Catherine; Carlson, Stephanie M; Gunnar, Megan R

    2012-10-16

    Executive function (EF) abilities are increasingly recognized as an important protective factor for children experiencing adversity, promoting better stress and emotion regulation as well as social and academic adjustment. We provide evidence that early life adversity is associated with significant reductions in EF performance on a developmentally sensitive battery of laboratory EF tasks that measured cognitive flexibility, working memory, and inhibitory control. Animal models also suggest that early adversity has a negative impact on the development of prefrontal cortex-based cognitive functions. In this study, we report EF performance 1 y after adoption in 2.5- to 4-y-old children who had experienced institutional care in orphanages overseas compared with a group of age-matched nonadopted children. To our knowledge, this is the youngest age and the soonest after adoption that reduced EF performance has been shown using laboratory measures in this population. EF reductions in performance were significant above and beyond differences in intelligence quotient. Within the adopted sample, current EF was associated with measures of early deprivation after controlling for intelligence quotient, with less time spent in the birth family before placement in an institution and lower quality of physical/social care in institutions predicting poorer performance on the EF battery.

  17. The Effects of a Brief Acceptance-Based Behavioral Treatment Versus Traditional Cognitive-Behavioral Treatment for Public Speaking Anxiety: An Exploratory Trial Examining Differential Effects on Performance and Neurophysiology.

    PubMed

    Glassman, Lisa H; Forman, Evan M; Herbert, James D; Bradley, Lauren E; Foster, Elizabeth E; Izzetoglu, Meltem; Ruocco, Anthony C

    2016-09-01

    Individuals with public speaking anxiety (PSA) experience fear and avoidance that can cause extreme distress, impaired speaking performance, and associated problems in psychosocial functioning. Most extant interventions for PSA emphasize anxiety reduction rather than enhancing behavioral performance. We compared the efficacy of two brief cognitive-behavioral interventions, a traditional cognitive-behavior treatment (tCBT) and an acceptance-based behavior treatment (ABBT), on public speaking performance and anxiety in a clinical sample of persons with PSA. The effects of treatment on prefrontal brain activation were also examined. Participants (n = 21) were randomized to 90 min of an ABBT or a tCBT intervention. Assessments took place at pre- and post-treatment and included self-rated anxiety and observer-rated performance measures, a behavioral assessment, and prefrontal cortical activity measurements using functional near-infrared spectroscopy (fNIRS). Exploratory results indicated that participants in the ABBT condition experienced greater improvements in observer-rated performance relative to those in the tCBT condition, while those in the tCBT condition experienced greater reductions in subjective anxiety levels. Individuals in the ABBT condition also exhibited a trend toward greater treatment-related reductions in blood volume in the left dorsolateral prefrontal cortex relative to those who received tCBT. Overall, these findings preliminarily suggest that acceptance-based treatments may free more cognitive resources in comparison with tCBT, possibly resulting in greater improvements in objectively rated behavioral performances for ABBT interventions. © The Author(s) 2016.

  18. Effect of Two Advanced Noise Reduction Technologies on the Aerodynamic Performance of an Ultra High Bypass Ratio Fan

    NASA Technical Reports Server (NTRS)

    Hughes, Christoper E.; Gazzaniga, John A.

    2013-01-01

    A wind tunnel experiment was conducted in the NASA Glenn Research Center anechoic 9- by 15-Foot Low-Speed Wind Tunnel to investigate two new advanced noise reduction technologies in support of the NASA Fundamental Aeronautics Program Subsonic Fixed Wing Project. The goal of the experiment was to demonstrate the noise reduction potential and effect on fan model performance of the two noise reduction technologies in a scale model Ultra-High Bypass turbofan at simulated takeoff and approach aircraft flight speeds. The two novel noise reduction technologies are called Over-the-Rotor acoustic treatment and Soft Vanes. Both technologies were aimed at modifying the local noise source mechanisms of the fan tip vortex/fan case interaction and the rotor wake-stator interaction. For the Over-the-Rotor acoustic treatment, two noise reduction configurations were investigated. The results showed that the two noise reduction technologies, Over-the-Rotor and Soft Vanes, were able to reduce the noise level of the fan model, but the Over-the-Rotor configurations had a significant negative impact on the fan aerodynamic performance; the loss in fan aerodynamic efficiency was between 2.75 to 8.75 percent, depending on configuration, compared to the conventional solid baseline fan case rubstrip also tested. Performance results with the Soft Vanes showed that there was no measurable change in the corrected fan thrust and a 1.8 percent loss in corrected stator vane thrust, which resulted in a total net thrust loss of approximately 0.5 percent compared with the baseline reference stator vane set.

  19. The Relationship of Teacher Evaluation Scores Generated by a Process-Product Evaluation Instrument to Selected Variables.

    ERIC Educational Resources Information Center

    Tadlock, James; Nesbit, Lamar

    The Jackson Municipal Separate School District, Mississippi, has instituted a mixed-criteria reduction-in-force procedure emphasizing classroom performance to a greater degree than seniority, certification, and staff development participation. The district evaluation process--measuring classroom teaching performance--generated data for the present…

  20. 7 CFR 275.23 - Determination of State agency program performance.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... national performance measure for the fiscal year, the State agency shall pay or have its share of... the prescribed timeframe. (8) Interest charges. (i) To the extent that a State agency does not pay a... agency agrees to pay the claim through reduction in Federal financial participation for administrative...

  1. On the skin friction drag reduction in large wind turbines using sharp V-grooved riblets. Application to a 2.5 MW Clipper wind turbine section

    NASA Astrophysics Data System (ADS)

    Arndt, Roger; Chamorro, Leonardo; Sotiropoulos, Fotis

    2010-11-01

    Skin friction drag reduction through the use of riblets has been a topic of intensive research during the last decades. Main efforts have been placed on both numerical (mainly DNS) and experimental approaches. In spite of the valuable efforts, the fundamental mechanisms that induce drag reduction are not well established. In this study, wind tunnel experiments were performed to quantify the drag reduction in a wind turbine airfoil using different V-groove riblet structures. A full-scale 2.5MW Clipper wind turbine airfoil section (of 1 meter chord length, typical of the 88% blade span), was placed in the freestream flow of the wind tunnel at the Saint Anthony Falls Laboratory, University of Minnesota. Four different sizes of V-groove riblets were tested at different angles of attack at full scale Reynolds number of Re=2.67x106 (based on the airfoil chord length). Force sensors were used to measure Lift and Drag. A combination of single and cross-wire anemometers were also used to study the turbulent scale-to-scale interaction in the near wall region to better understand the physical mechanisms of drag reduction and flow characteristics in that region. The measurements will be used to develop and test the performance of near-wall boundary conditions in the context of RANS and hybrid RANS/LES models.

  2. Flight Test Techniques Used to Evaluate Performance Benefits During Formation Flight

    NASA Technical Reports Server (NTRS)

    Ray, Ronald J.; Cobleigh, Brent R.; Vachon, M. Jake; SaintJohn, Clinton

    2002-01-01

    The Autonomous Formation Flight research project has been implemented at the NASA Dryden Flight Research Center to demonstrate the benefits of formation flight and develop advanced technologies to facilitate exploiting these benefits. Two F/A-18 aircraft have been modified to precisely control and monitor relative position, and to determine performance of the trailing airplane. Flight test maneuvers and analysis techniques have been developed to determine the performance advantages, including drag and fuel flow reductions and improvements in range factor. By flying the trailing airplane through a matrix of lateral, longitudinal, and vertical offset positions, a detailed map of the performance benefits has been obtained at two flight conditions. Significant performance benefits have been obtained during this flight test phase. Drag reductions of more than 20 percent and fuel flow reductions of more than 18 percent have been measured at flight conditions of Mach 0.56 and an altitude of 25,000 ft. The results show favorable agreement with published theory and generic predictions. An F/A-18 long-range cruise mission at Mach 0.8 and an altitude of 40,000 ft has been simulated in the optimum formation position and has demonstrated a 14-percent fuel reduction when compared with a controlled chase airplane of similar configuration.

  3. Efficacy of radiation safety glasses in interventional radiology.

    PubMed

    van Rooijen, Bart D; de Haan, Michiel W; Das, Marco; Arnoldussen, Carsten W K P; de Graaf, R; van Zwam, Wim H; Backes, Walter H; Jeukens, Cécile R L P N

    2014-10-01

    This study was designed to evaluate the reduction of the eye lens dose when wearing protective eyewear in interventional radiology and to identify conditions that optimize the efficacy of radiation safety glasses. The dose reduction provided by different models of radiation safety glasses was measured on an anthropomorphic phantom head. The influence of the orientation of the phantom head on the dose reduction was studied in detail. The dose reduction in interventional radiological practice was assessed by dose measurements on radiologists wearing either leaded or no glasses or using a ceiling suspended screen. The different models of radiation safety glasses provided a dose reduction in the range of a factor of 7.9-10.0 for frontal exposure of the phantom. The dose reduction was strongly reduced when the head is turned to the side relative to the irradiated volume. The eye closest to the tube was better protected due to side shielding and eyewear curvature. In clinical practice, the mean dose reduction was a factor of 2.1. Using a ceiling suspended lead glass shield resulted in a mean dose reduction of a factor of 5.7. The efficacy of radiation protection glasses depends on the orientation of the operator's head relative to the irradiated volume. Glasses can offer good protection to the eye under clinically relevant conditions. However, the performance in clinical practice in our study was lower than expected. This is likely related to nonoptimized room geometry and training of the staff as well as measurement methodology.

  4. Measurements and Predictions for a Distributed Exhaust Nozzle

    NASA Technical Reports Server (NTRS)

    Kinzie, Kevin W.; Brown, Martha C.; Schein, David B.; Solomon, W. David, Jr.

    2001-01-01

    The acoustic and aerodynamic performance characteristics of a distributed exhaust nozzle (DEN) design concept were evaluated experimentally and analytically with the purpose of developing a design methodology for developing future DEN technology. Aerodynamic and acoustic measurements were made to evaluate the DEN performance and the CFD design tool. While the CFD approach did provide an excellent prediction of the flowfield and aerodynamic performance characteristics of the DEN and 2D reference nozzle, the measured acoustic suppression potential of this particular DEN was low. The measurements and predictions indicated that the mini-exhaust jets comprising the distributed exhaust coalesced back into a single stream jet very shortly after leaving the nozzles. Even so, the database provided here will be useful for future distributed exhaust designs with greater noise reduction and aerodynamic performance potential.

  5. Effect of Complete Syndesmotic Disruption and Deltoid Injuries and Different Reduction Methods on Ankle Joint Contact Mechanics.

    PubMed

    LaMothe, Jeremy; Baxter, Josh R; Gilbert, Susannah; Murphy, Conor I; Karnovsky, Sydney C; Drakos, Mark C

    2017-06-01

    Syndesmotic injuries can be associated with poor patient outcomes and posttraumatic ankle arthritis, particularly in the case of malreduction. However, ankle joint contact mechanics following a syndesmotic injury and reduction remains poorly understood. The purpose of this study was to characterize the effects of a syndesmotic injury and reduction techniques on ankle joint contact mechanics in a biomechanical model. Ten cadaveric whole lower leg specimens with undisturbed proximal tibiofibular joints were prepared and tested in this study. Contact area, contact force, and peak contact pressure were measured in the ankle joint during simulated standing in the intact, injured, and 3 reduction conditions: screw fixation with a clamp, screw fixation without a clamp (thumb technique), and a suture-button construct. Differences in these ankle contact parameters were detected between conditions using repeated-measures analysis of variance. Syndesmotic disruption decreased tibial plafond contact area and force. Syndesmotic reduction did not restore ankle loading mechanics to values measured in the intact condition. Reduction with the thumb technique was able to restore significantly more joint contact area and force than the reduction clamp or suture-button construct. Syndesmotic disruption decreased joint contact area and force. Although the thumb technique performed significantly better than the reduction clamp and suture-button construct, syndesmotic reduction did not restore contact mechanics to intact levels. Decreased contact area and force with disruption imply that other structures are likely receiving more loads (eg, medial and lateral gutters), which may have clinical implications such as the development of posttraumatic arthritis.

  6. 17 CFR 200.13 - Executive Director.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... AND ETHICS; AND INFORMATION AND REQUESTS Organization and Program Management General Organization... procurement regulations, enters into contracts, designates contracting officers, and makes procurement...-specific application of performance measures, procurement reforms, personnel reductions, financial...

  7. Predictors of changes in gait performance over four years in persons with late effects of polio.

    PubMed

    Flansbjer, Ulla-Britt; Lexell, Jan; Brogårdh, Christina

    2017-01-01

    Reduced gait performance is common in persons with late effects of polio. To identify predictors of change in gait performance over four years in persons with late effects of polio. Gait performance was assessed annually in 51 ambulatory persons (mean age 64 years, SD 6) by the Timed "Up & Go" (TUG), Comfortable and Fast Gait Speed (CGS, FGS), and 6-Minute Walk Test (6MWT). Isokinetic knee extensor and flexor muscle strength was measured with a Biodex dynamometer. Mixed Linear Models were used to analyze changes in gait performance and to identify any predictors of change among the covariates gender, age, body mass index, time with new symptoms, baseline reduction in gait performance and knee muscle strength. There were significant linear effects over time (reduction per year) for three gait performance tests; CGS (0.8%; p < 0.05), FGS (1.7%; p < 0.001), and 6MWT (0.7%; p < 0.05) with significant random effects for all tests. The strongest predictor of a change in gait performance was the individual variations in the knee flexor strength (p < 0.001). The small gradual reduction in gait performance over time in persons with late effects of polio is primarily determined by the individual variations in the knee flexor strength.

  8. Comparing Binaural Pre-processing Strategies I: Instrumental Evaluation.

    PubMed

    Baumgärtel, Regina M; Krawczyk-Becker, Martin; Marquardt, Daniel; Völker, Christoph; Hu, Hongmei; Herzke, Tobias; Coleman, Graham; Adiloğlu, Kamil; Ernst, Stephan M A; Gerkmann, Timo; Doclo, Simon; Kollmeier, Birger; Hohmann, Volker; Dietz, Mathias

    2015-12-30

    In a collaborative research project, several monaural and binaural noise reduction algorithms have been comprehensively evaluated. In this article, eight selected noise reduction algorithms were assessed using instrumental measures, with a focus on the instrumental evaluation of speech intelligibility. Four distinct, reverberant scenarios were created to reflect everyday listening situations: a stationary speech-shaped noise, a multitalker babble noise, a single interfering talker, and a realistic cafeteria noise. Three instrumental measures were employed to assess predicted speech intelligibility and predicted sound quality: the intelligibility-weighted signal-to-noise ratio, the short-time objective intelligibility measure, and the perceptual evaluation of speech quality. The results show substantial improvements in predicted speech intelligibility as well as sound quality for the proposed algorithms. The evaluated coherence-based noise reduction algorithm was able to provide improvements in predicted audio signal quality. For the tested single-channel noise reduction algorithm, improvements in intelligibility-weighted signal-to-noise ratio were observed in all but the nonstationary cafeteria ambient noise scenario. Binaural minimum variance distortionless response beamforming algorithms performed particularly well in all noise scenarios. © The Author(s) 2015.

  9. Measured and predicted impingement noise for a model-scale under the wing externally blown flap configuration with a QCSEE type nozzle

    NASA Technical Reports Server (NTRS)

    Mckinzie, D. J., Jr.

    1980-01-01

    Jet/flap interaction noise was measured and predicted for a small-scale model two-flap, under-the-wing, externally blown flap configuration equipped with and without noise suppression devices. The devices consisted of short spanwise fairings centered in relationship to the jet axis and positioned in the slots between the wing and flaps. The nozzle approximated that of the Quiet Clean Short-haul Experimental Engine (QCSEE). Takeoff noise reductions of 6 dB in the flyover and 5 dB in the sideline plane were obtained over a wide range of radiation angles. Approach noise reductions of about 5 dB were obtained only in the forward quadrant of the flyover plane; no reductions were obtained in the sideline plane. Models of several noise sources were combined analytically to form an overall noise prediction, the results from which compared favorably with the measured data. The aerodynamic performance characteristics for these configurations were substantially the same in the takeoff attitude. However, in the approach attitude, the suppressed configuration produced a 6 percent reduction in the flow turning efficiency.

  10. Comparing Binaural Pre-processing Strategies I

    PubMed Central

    Krawczyk-Becker, Martin; Marquardt, Daniel; Völker, Christoph; Hu, Hongmei; Herzke, Tobias; Coleman, Graham; Adiloğlu, Kamil; Ernst, Stephan M. A.; Gerkmann, Timo; Doclo, Simon; Kollmeier, Birger; Hohmann, Volker; Dietz, Mathias

    2015-01-01

    In a collaborative research project, several monaural and binaural noise reduction algorithms have been comprehensively evaluated. In this article, eight selected noise reduction algorithms were assessed using instrumental measures, with a focus on the instrumental evaluation of speech intelligibility. Four distinct, reverberant scenarios were created to reflect everyday listening situations: a stationary speech-shaped noise, a multitalker babble noise, a single interfering talker, and a realistic cafeteria noise. Three instrumental measures were employed to assess predicted speech intelligibility and predicted sound quality: the intelligibility-weighted signal-to-noise ratio, the short-time objective intelligibility measure, and the perceptual evaluation of speech quality. The results show substantial improvements in predicted speech intelligibility as well as sound quality for the proposed algorithms. The evaluated coherence-based noise reduction algorithm was able to provide improvements in predicted audio signal quality. For the tested single-channel noise reduction algorithm, improvements in intelligibility-weighted signal-to-noise ratio were observed in all but the nonstationary cafeteria ambient noise scenario. Binaural minimum variance distortionless response beamforming algorithms performed particularly well in all noise scenarios. PMID:26721920

  11. Efficacy of percutaneous electrical nerve stimulation for the treatment of chronic low back pain in older adults.

    PubMed

    Weiner, Debra K; Rudy, Thomas E; Glick, Ronald M; Boston, J Robert; Lieber, Susan J; Morrow, Lisa A; Taylor, Stephen

    2003-05-01

    To determine the efficacy of a complementary analgesic modality, percutaneous electrical nerve stimulation (PENS), for the treatment of chronic low back pain (CLBP) in community-dwelling older adults. Randomized, controlled clinical trial. University of Pittsburgh Pain Evaluation and Treatment Institute. Thirty-four English speaking, community-dwelling adults aged 65 and older with CLBP of at least moderate intensity experienced every day or almost every day. Subjects were randomized to receive twice-weekly PENS and physical therapy (PT) or sham PENS and physical therapy for 6 weeks. At baseline, immediately after the 6-week intervention period, and 3 months later, the primary outcome measures pain intensity and pain-related disability were assessed. The secondary outcome measures physical performance (timed chair rise, functional reach, gait speed, static and isoinertial lifting), psychosocial factors (mood, sleep, and life control), and cognitive function (measures of attention, concentration, and mental flexibility) were also collected. Subjects randomized to PENS plus PT displayed significant reductions in pain intensity measures from pre- to posttreatment (P <.001), but the sham PENS plus PT group did not (P =.94). These pain reduction effects were maintained at 3-month follow-up. Similarly, significant reductions in pain-related disability were observed at posttreatment (P =.002) for the PENS plus PT group and were maintained at follow-up, but the sham PENS plus PT group did not show reductions in pain-related disability (P =.81). Of the secondary outcome measures, psychosocial function, timed chair rise, and isoinertial lifting endurance also improved significantly at posttreatment for the PENS plus PT group, and their improvement was sustained at 3-month follow-up, but the sham PENS plus PT did not display significant changes on these measures after treatment. This preliminary study suggests that PENS may be a promising treatment modality for community-dwelling older adults with CLBP, as demonstrated by reduction in pain intensity and self-reported disability, and improvement in mood, life control, and physical performance. Larger studies with longer duration of follow-up are needed to validate these findings and support the use of PENS in clinical practice.

  12. Long-term performance evaluation of positron emission tomography: analysis and proposal of a maintenance protocol for long-term utilization.

    PubMed

    Watanuki, Shoichi; Tashiro, Manabu; Miyake, Masayasu; Ishikawa, Yoichi; Itoh, Masatoshi; Yanai, Kazuhiko; Sakemi, Yasuhiro; Fukuda, Hiroshi; Ishii, Keizo

    2010-07-01

    Positron emission tomography (PET) scanners require periodic monitoring in order to maintain scanner performance. The aim of the present study was to examine the deterioration of PET scanner performance caused by aging. We retrospectively examined PET scanner performance alterations in terms of sensitivity, spatial resolution, false coincidences due to scatter and random coincidences based on 13 years of follow-up data, including data when the PET scanner underwent an overhaul at the 10th year after installation. Sensitivity and scatter fraction were calculated by using cross calibration factor (CCF) measurement data, which are collected routinely. Efficacy of the examining the sensitivity and scatter was confirmed by NEMA measurements. Trans-axial resolution was measured as full width at half-maximum (FWHM) and full width at tenth-maximum (FWTM) at 0-20 cm offset from the field of view (FOV) center at the time of installation, 8 years after installation, and immediately after the overhaul. Random coincidence rate fraction was measured in a wide range of count rates before and after the overhaul. The results indicated that the total reduction of sensitivity during the first 10 years was 41% of the initial value in terms of NEMA measurement, and that the annual reduction of sensitivity progressed at a rate of 4.7% per year in terms of CCF measurement data. The changes in sensitivity can be calculated using CCF measurement data. Regarding the spatial resolution, mean FWHM and FWTM values were increased by 1.7 and 3.6%, respectively, in 8 years after installation. The relative scatter fraction was significantly increased compared with that before the overhaul. The random fraction decreased by 10-15% after the overhaul within a certain range of random count rates (1-120 kcps). In the case of our scanner, the parameter that displayed the largest change was the sensitivity, and this change was thought to be caused by the reduction of photomultiplier tube (PMT) gain, although the changes in PMT gain can cause various types of performance deterioration, as investigated in this study. We observed that the sensitivity of our PET scanner generally deteriorated due to aging. Sensitivity monitoring using CCF measurements can be an easy and useful method for monitoring and maintaining the performance of PET scanners against aging. Since the data were obtained from a single scanner, the authors would encourage the initiation of a follow-up study involving various scanners.

  13. Comparison of the effect of different modalities of physical exercise on functionality and anthropometric measurements in community-dwelling older women.

    PubMed

    Vasconcelos, Ana Paula Sena Lomba; Cardozo, Diogo Correia; Lucchetti, Alessandra Lamas Granero; Lucchetti, Giancarlo

    2016-10-01

    The present study aims to assess the effect of different modalities of physical exercises ("Functional Gymnastics"-FG, "Resistance Training"-RT and "Pilates combined with Hydrogymnastics"-PCH) on functional capacity and anthropometric measurements of 148 older women (60 years old or more). A comparative observational study was conducted. Functional and anthropometric measurements were assessed at baseline and after 16 weeks. All groups assessed showed significant changes between baseline and post-training. On the comparison of pre and post-training, differences in anthropometric measurements but not in functional test performance were found. The PCH had greater weight loss compared to the FG and RT, reduction in BMI compared to the FG and RT; reduction in waist compared to the FG and RT, and in hip compared to the RT. Although all groups improved, Pilates/Hydrogymnastics combination was more strongly associated with reductions in weight, BMI, waist and hip measurements but not functionality, than other modalities. These results highlight the role of combination physical exercise training in older women. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Improved Kalman Filter Method for Measurement Noise Reduction in Multi Sensor RFID Systems

    PubMed Central

    Eom, Ki Hwan; Lee, Seung Joon; Kyung, Yeo Sun; Lee, Chang Won; Kim, Min Chul; Jung, Kyung Kwon

    2011-01-01

    Recently, the range of available Radio Frequency Identification (RFID) tags has been widened to include smart RFID tags which can monitor their varying surroundings. One of the most important factors for better performance of smart RFID system is accurate measurement from various sensors. In the multi-sensing environment, some noisy signals are obtained because of the changing surroundings. We propose in this paper an improved Kalman filter method to reduce noise and obtain correct data. Performance of Kalman filter is determined by a measurement and system noise covariance which are usually called the R and Q variables in the Kalman filter algorithm. Choosing a correct R and Q variable is one of the most important design factors for better performance of the Kalman filter. For this reason, we proposed an improved Kalman filter to advance an ability of noise reduction of the Kalman filter. The measurement noise covariance was only considered because the system architecture is simple and can be adjusted by the neural network. With this method, more accurate data can be obtained with smart RFID tags. In a simulation the proposed improved Kalman filter has 40.1%, 60.4% and 87.5% less Mean Squared Error (MSE) than the conventional Kalman filter method for a temperature sensor, humidity sensor and oxygen sensor, respectively. The performance of the proposed method was also verified with some experiments. PMID:22346641

  15. Improved Kalman filter method for measurement noise reduction in multi sensor RFID systems.

    PubMed

    Eom, Ki Hwan; Lee, Seung Joon; Kyung, Yeo Sun; Lee, Chang Won; Kim, Min Chul; Jung, Kyung Kwon

    2011-01-01

    Recently, the range of available radio frequency identification (RFID) tags has been widened to include smart RFID tags which can monitor their varying surroundings. One of the most important factors for better performance of smart RFID system is accurate measurement from various sensors. In the multi-sensing environment, some noisy signals are obtained because of the changing surroundings. We propose in this paper an improved Kalman filter method to reduce noise and obtain correct data. Performance of Kalman filter is determined by a measurement and system noise covariance which are usually called the R and Q variables in the Kalman filter algorithm. Choosing a correct R and Q variable is one of the most important design factors for better performance of the Kalman filter. For this reason, we proposed an improved Kalman filter to advance an ability of noise reduction of the Kalman filter. The measurement noise covariance was only considered because the system architecture is simple and can be adjusted by the neural network. With this method, more accurate data can be obtained with smart RFID tags. In a simulation the proposed improved Kalman filter has 40.1%, 60.4% and 87.5% less mean squared error (MSE) than the conventional Kalman filter method for a temperature sensor, humidity sensor and oxygen sensor, respectively. The performance of the proposed method was also verified with some experiments.

  16. Measuring the value of process improvement initiatives in a preoperative assessment center using time-driven activity-based costing.

    PubMed

    French, Katy E; Albright, Heidi W; Frenzel, John C; Incalcaterra, James R; Rubio, Augustin C; Jones, Jessica F; Feeley, Thomas W

    2013-12-01

    The value and impact of process improvement initiatives are difficult to quantify. We describe the use of time-driven activity-based costing (TDABC) in a clinical setting to quantify the value of process improvements in terms of cost, time and personnel resources. Difficulty in identifying and measuring the cost savings of process improvement initiatives in a Preoperative Assessment Center (PAC). Use TDABC to measure the value of process improvement initiatives that reduce the costs of performing a preoperative assessment while maintaining the quality of the assessment. Apply the principles of TDABC in a PAC to measure the value, from baseline, of two phases of performance improvement initiatives and determine the impact of each implementation in terms of cost, time and efficiency. Through two rounds of performance improvements, we quantified an overall reduction in time spent by patient and personnel of 33% that resulted in a 46% reduction in the costs of providing care in the center. The performance improvements resulted in a 17% decrease in the total number of full time equivalents (FTE's) needed to staff the center and a 19% increase in the numbers of patients assessed in the center. Quality of care, as assessed by the rate of cancellations on the day of surgery, was not adversely impacted by the process improvements. © 2013 Published by Elsevier Inc.

  17. Physical and biological characterization of a seawater ultraviolet radiation sterilizer

    NASA Astrophysics Data System (ADS)

    Torrentera, Laura; Uribe, Roberto M.; Rodríguez, Romana R.; Carrillo, Ricardo E.

    1994-03-01

    The physical and biological characterization of a seawater ultraviolet (UV) sterilizer is described. The physical characterization was performed using radiochromic dye films by evaluating the uniformity of the radiant exposure along each lamp, the effect of the radiation from one lamp on the array of adjacent lamps, and by measuring the UV radiation absorption of seawater with respect to distilled water. The biological characterization was performed by measuring the amount of reduction of bacteria in stored seawater after different filtration and UV treatments. Among the filtration methods tested, differential filtration (5, 3 and 0.45 μm filters connected in series) caused the highest bacterial reduction factor of 60%. UV radiant exposures of 212, 424, 636 and 848 J m -2 yielded bacteria reduction factors of 99.86, 99.969, 99.997 and 100%, respectively, for populations of Vibrio and Pseudomonas bacteria present in stored seawater. It is concluded that the system is useful for water disinfection when 1, 2 or 3 lamps are on; when 4 lamps are used the treated water becomes sterile.

  18. Econo-ESA in semantic text similarity.

    PubMed

    Rahutomo, Faisal; Aritsugi, Masayoshi

    2014-01-01

    Explicit semantic analysis (ESA) utilizes an immense Wikipedia index matrix in its interpreter part. This part of the analysis multiplies a large matrix by a term vector to produce a high-dimensional concept vector. A similarity measurement between two texts is performed between two concept vectors with numerous dimensions. The cost is expensive in both interpretation and similarity measurement steps. This paper proposes an economic scheme of ESA, named econo-ESA. We investigate two aspects of this proposal: dimensional reduction and experiments with various data. We use eight recycling test collections in semantic text similarity. The experimental results show that both the dimensional reduction and test collection characteristics can influence the results. They also show that an appropriate concept reduction of econo-ESA can decrease the cost with minor differences in the results from the original ESA.

  19. Reduction of surface leakage current by surface passivation of CdZn Te and other materials using hyperthermal oxygen atoms

    DOEpatents

    Hoffbauer, Mark A.; Prettyman, Thomas H.

    2001-01-01

    Reduction of surface leakage current by surface passivation of Cd.sub.1-x Zn.sub.x Te and other materials using hyperthermal oxygen atoms. Surface effects are important in the performance of CdZnTe room-temperature radiation detectors used as spectrometers since the dark current is often dominated by surface leakage. A process using high-kinetic-energy, neutral oxygen atoms (.about.3 eV) to treat the surface of CdZnTe detectors at or near ambient temperatures is described. Improvements in detector performance include significantly reduced leakage current which results in lower detector noise and greater energy resolution for radiation measurements of gamma- and X-rays, thereby increasing the accuracy and sensitivity of measurements of radionuclides having complex gamma-ray spectra, including special nuclear materials.

  20. Time Savings and Surgery Task Load Reduction in Open Intraperitoneal Onlay Mesh Fixation Procedure.

    PubMed

    Roy, Sanjoy; Hammond, Jeffrey; Panish, Jessica; Shnoda, Pullen; Savidge, Sandy; Wilson, Mark

    2015-01-01

    This study assessed the reduction in surgeon stress associated with savings in procedure time for mechanical fixation of an intraperitoneal onlay mesh (IPOM) compared to a traditional suture fixation in open ventral hernia repair. Nine general surgeons performed 36 open IPOM fixation procedures in porcine model. Each surgeon conducted two mechanical (using ETHICON SECURESTRAP ™ Open) and two suture fixation procedures. Fixation time was measured using a stopwatch, and related surgeon stress was assessed using the validated SURG-TLX questionnaire. T-tests were used to compare between-group differences, and a two-sided 95% confidence interval for the difference in stress levels was established using nonparametric methodology. The mechanical fixation group demonstrated an 89.1% mean reduction in fixation time, as compared to the suture group (p < 0.00001). Surgeon stress scores measured using SURG-TLX were 55.5% lower in the mechanical compared to the suture fixation group (p < 0.001). Scores in five of the six sources of stress were significantly lower for mechanical fixation. Mechanical fixation with ETHICON SECURESTRAP ™ Open demonstrated a significant reduction in fixation time and surgeon stress, which may translate into improved operating efficiency, improved performance, improved surgeon quality of life, and reduced overall costs of the procedure.

  1. Time Savings and Surgery Task Load Reduction in Open Intraperitoneal Onlay Mesh Fixation Procedure

    PubMed Central

    Roy, Sanjoy; Hammond, Jeffrey; Panish, Jessica; Shnoda, Pullen; Savidge, Sandy; Wilson, Mark

    2015-01-01

    Background. This study assessed the reduction in surgeon stress associated with savings in procedure time for mechanical fixation of an intraperitoneal onlay mesh (IPOM) compared to a traditional suture fixation in open ventral hernia repair. Study Design. Nine general surgeons performed 36 open IPOM fixation procedures in porcine model. Each surgeon conducted two mechanical (using ETHICON SECURESTRAPTM Open) and two suture fixation procedures. Fixation time was measured using a stopwatch, and related surgeon stress was assessed using the validated SURG-TLX questionnaire. T-tests were used to compare between-group differences, and a two-sided 95% confidence interval for the difference in stress levels was established using nonparametric methodology. Results. The mechanical fixation group demonstrated an 89.1% mean reduction in fixation time, as compared to the suture group (p < 0.00001). Surgeon stress scores measured using SURG-TLX were 55.5% lower in the mechanical compared to the suture fixation group (p < 0.001). Scores in five of the six sources of stress were significantly lower for mechanical fixation. Conclusions. Mechanical fixation with ETHICON SECURESTRAPTM Open demonstrated a significant reduction in fixation time and surgeon stress, which may translate into improved operating efficiency, improved performance, improved surgeon quality of life, and reduced overall costs of the procedure. PMID:26240834

  2. Impact of hydrogeological data on measures of uncertainty, site characterization and environmental performance metrics

    NASA Astrophysics Data System (ADS)

    de Barros, Felipe P. J.; Ezzedine, Souheil; Rubin, Yoram

    2012-02-01

    The significance of conditioning predictions of environmental performance metrics (EPMs) on hydrogeological data in heterogeneous porous media is addressed. Conditioning EPMs on available data reduces uncertainty and increases the reliability of model predictions. We present a rational and concise approach to investigate the impact of conditioning EPMs on data as a function of the location of the environmentally sensitive target receptor, data types and spacing between measurements. We illustrate how the concept of comparative information yield curves introduced in de Barros et al. [de Barros FPJ, Rubin Y, Maxwell R. The concept of comparative information yield curves and its application to risk-based site characterization. Water Resour Res 2009;45:W06401. doi:10.1029/2008WR007324] could be used to assess site characterization needs as a function of flow and transport dimensionality and EPMs. For a given EPM, we show how alternative uncertainty reduction metrics yield distinct gains of information from a variety of sampling schemes. Our results show that uncertainty reduction is EPM dependent (e.g., travel times) and does not necessarily indicate uncertainty reduction in an alternative EPM (e.g., human health risk). The results show how the position of the environmental target, flow dimensionality and the choice of the uncertainty reduction metric can be used to assist in field sampling campaigns.

  3. Effect Of Oxidation On Chromium Leaching And Redox Capacity Of Slag-Containing Waste Forms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Almond, P. M.; Stefanko, D. B.; Langton, C. A.

    2013-03-01

    The rate of oxidation is important to the long-term performance of reducing salt waste forms because the solubility of some contaminants, e.g., technetium, is a function of oxidation state. TcO 4 - in the salt solution is reduced to Tc(IV) and has been shown to react with ingredients in the waste form to precipitate low solubility sulfide and/or oxide phases [Shuh, et al., 1994, Shuh, et al., 2000, Shuh, et al., 2003]. Upon exposure to oxygen, the compounds containing Tc(IV) oxidize to the pertechnetate ion, Tc(VII)O 4 -, which is very soluble. Consequently the rate of technetium oxidation front advancementmore » into a monolith and the technetium leaching profile as a function of depth from an exposed surface are important to waste form performance and ground water concentration predictions. An approach for measuring contaminant oxidation rate (effective contaminant specific oxidation rate) based on leaching of select contaminants of concern is described in this report. In addition, the relationship between reduction capacity and contaminant oxidation is addressed. Chromate was used as a non-radioactive surrogate for pertechnetate in simulated waste form samples. Depth discrete subsamples were cut from material exposed to Savannah River Site (SRS) field cured conditions. The subsamples were prepared and analyzed for both reduction capacity and chromium leachability. Results from field-cured samples indicate that the depth at which leachable chromium was detected advanced further into the sample exposed for 302 days compared to the sample exposed to air for 118 days (at least 50 mm compared to at least 20 mm). Data for only two exposure time intervals is currently available. Data for additional exposure times are required to develop an equation for the oxidation front progression. Reduction capacity measurements (per the Angus-Glasser method, which is a measurement of the ability of a material to chemically reduce Ce(IV) to Ce(III) in solution) performed on depth discrete samples could not be correlated with the amount of chromium leached from the depth discrete subsamples or with the oxidation front inferred from soluble chromium (i.e., effective Cr oxidation front). Exposure to oxygen (air or oxygen dissolved in water) results in the release of chromium through oxidation of Cr(III) to highly soluble chromate, Cr(VI). Residual reduction capacity in the oxidized region of the test samples indicates that the remaining reduction capacity is not effective in re-reducing Cr(VI) in the presence of oxygen. Consequently, this method for determining reduction capacity may not be a good indicator of the effective contaminant oxidation rate in a relatively porous solid (40 to 60 volume percent porosity). The chromium extracted in depth discrete samples ranged from a maximum of about 5.8 % at about 5 mm (118 day exposure) to about 4 % at about 10 mm (302 day exposure). The use of reduction capacity as an indicator of long-term performance requires further investigation. The carbonation front was also estimated to have advanced to at least 28 mm in 302 days based on visual observation of gas evolution during acid addition during the reduction capacity measurements. Depth discrete sampling of materials exposed to realistic conditions in combination with short term leaching of crushed samples has potential for advancing the understanding of factors influencing performance and will support conceptual model development.« less

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cornacchia, Massimo

    The VISA (Visible to Infrared SASE Amplifier) SASE free electron laser has been successfully operated at the Accelerator Test Facility (ATF) at BNL. High gain and saturation were observed at 840 nm. We describe here the diagnostic system, experimental procedures and data reduction algorithms, as the FEL performance was measured along the length of the undulator. We also discuss selected spectral radiation measurements.

  5. Aeroacoustic Analysis of Fan Noise Reduction With Increased Bypass Nozzle Area

    NASA Technical Reports Server (NTRS)

    Woodward, Richard P.; Hughes, Christopher E.; Podboy, Gary G.

    2005-01-01

    An advanced model turbofan was tested in the NASA Glenn 9-by 15-Foot Low Speed Wind Tunnel (9x15 LSWT) to explore far field acoustic effects of increased bypass nozzle area. This fan stage test was part of the NASA Glenn Fan Broadband Source Diagnostic Test, second entry (SDT2) which acquired aeroacoustic results over a range of test conditions. The baseline nozzle was sized to produce maximum stage performance at cruise condition. However, the wind tunnel testing is conducted near sea level condition. Therefore, in order to simulate and obtain performance at other operating conditions, two additional nozzles were designed and tested one with +5 percent increase in weight flow (+5.4 percent increase in nozzle area compared with the baseline nozzle), sized to simulate the performance at the stage design point (takeoff) condition, and the other with a +7.5 percent increase in weight flow (+10.9 percent increase in nozzle area) sized for maximum weight flow with a fixed nozzle at sea level condition. Measured acoustic benefits with increased nozzle area were very encouraging, showing overall sound power level (OAPWL) reductions of 2 or more dB while the stage thrust actually increased by 2 to 3 percent except for the most open nozzle at takeoff rotor speed where stage performance decreased. Effective perceived noise levels for a 1500 ft engine flyover and 3.35 scale factor showed a similar noise reduction of 2 or more EPNdB. Noise reductions, principally in the level of broadband noise, were observed everywhere in the far field. Laser Doppler Velocimetry measurements taken downstream of the rotor showed that the total turbulent velocity decreased with increasing nozzle flow, which may explain the reduced rotor broadband noise levels.

  6. G-300: The first French Getaway Special microgravity measurements of fluid thermal conductivity

    NASA Technical Reports Server (NTRS)

    Perron, J. C.; Chretien, P.; Garnier, C.; Lecaude, N.

    1987-01-01

    Thermal conductivity measurements on liquids are difficult to perform on Earth because of thermal motions due to convection. In microgravity, the convection due to buoyancy is evanescent, and a strong reduction of Rayleigh and Nusselt numbers can be expected. Three low viscosity liquids are selected to carry out the measurements; distilled water (standard) and two silicone oils. A modified hot plate method with a simplified guard ring is used; the reduction of convective motions permitted the use in the experimental cells of larger interplate distances and/or temperature differences than in Earth measurements, improving the accuracy. Comparisons between Earth and orbit results may help to understand the convection occurrence in the cells. Thermal, vibrational, and EMI tests have proved that the design satisfies the NASA requirements.

  7. On-Orbit Performance Degradation of the International Space Station P6 Photovoltaic Arrays

    NASA Technical Reports Server (NTRS)

    Kerslake, Thomas W.; Gustafson, Eric D.

    2003-01-01

    This paper discusses the on-orbit performance and performance degradation of the International Space Station P6 solar array wings (SAWs) from the period of December 2000 through February 2003. Data selection considerations and data reduction methods are reviewed along with the approach for calculating array performance degradation based on measured string shunt current levels. Measured degradation rates are compared with those predicted by the computational tool SPACE and prior degradation rates measured with the same SAW technology on the Mir space station. Initial results show that the measured SAW short-circuit current is degrading 0.2 to 0.5 percent per year. This degradation rate is below the predicted rate of 0.8 percent per year and is well within the 3 percent estimated uncertainty in measured SAW current levels. General contributors to SAW degradation are briefly discussed.

  8. Assessing the performance of sewer rehabilitation on the reduction of infiltration and inflow.

    PubMed

    Staufer, P; Scheidegger, A; Rieckermann, J

    2012-10-15

    Inflow and Infiltration (I/I) into sewer systems is generally unwanted, because, among other things, it decreases the performance of wastewater treatment plants and increases combined sewage overflows. As sewer rehabilitation to reduce I/I is very expensive, water managers not only need methods to accurately measure I/I, but also they need sound approaches to assess the actual performance of implemented rehabilitation measures. However, such performance assessment is rarely performed. On the one hand, it is challenging to adequately take into account the variability of influential factors, such as hydro-meteorological conditions. On the other hand, it is currently not clear how experimental data can indeed support robust evidence for reduced I/I. In this paper, we therefore statistically assess the performance of rehabilitation measures to reduce I/I. This is possible by using observations in a suitable reference catchment as a control group and assessing the significance of the observed effect by regression analysis, which is well established in other disciplines. We successfully demonstrate the usefulness of the approach in a case study, where rehabilitation reduced groundwater infiltration by 23.9%. A reduction of stormwater inflow of 35.7%, however, was not statistically significant. Investigations into the experimental design of monitoring campaigns confirmed that the variability of the data as well as the number of observations collected before the rehabilitation impact the detection limit of the effect. This implies that it is difficult to improve the data quality after the rehabilitation has been implemented. Therefore, future practical applications should consider a careful experimental design. Further developments could employ more sophisticated monitoring methods, such as stable environmental isotopes, to directly observe the individual infiltration components. In addition, water managers should develop strategies to effectively communicate statistically not significant I/I reduction ratios to decision makers. Copyright © 2012 Elsevier Ltd. All rights reserved.

  9. A scanning probe investigation of the role of surface motifs in the behavior of p-WSe 2 photocathodes

    DOE PAGES

    Velazquez, Jesus M.; John, Jimmy; Esposito, Daniel V.; ...

    2015-10-08

    The spatial variation in the photoelectrochemical performance for the reduction of an aqueous one-electron redox couple, Ru(NH 3) 6 3+/2+, and for the evolution of H 2(g) from 0.5 M H 2SO 4(aq) at the surface of bare or Pt-decorated p-type WSe 2 photocathodes has been investigated in situ using scanning photocurrent microscopy (SPCM). The measurements revealed significant differences in the charge-collection performance (quantified by the values of external quantum yields, Φ ext) on various macroscopic terraces. Local spectral response measurements indicated a variation in the local electronic structure among the terraces, which was consistent with a non-uniform spatial distributionmore » of sub-band-gap states within the crystals. The photoconversion efficiencies of Pt-decorated p-WSe2 photocathodes were greater for the evolution of H 2(g) from 0.5 M H 2SO 4 than for the reduction of Ru(NH 3) 6 3+/2+, and terraces that exhibited relatively low values of Φext for the reduction of Ru(NH 3) 6 3+/2+ could in some cases yield values of Φ ext for the evolution of H 2(g) comparable to the values of Φ ext yielded by the highest-performing terraces. In conclusion, although the spatial resolution of the techniques used in this work frequently did not result in observation of the effect of edge sites on photocurrent efficiency, some edge effects were observed in the measurements; however the observed edge effects differed among edges, and did not appear to determine the performance of the electrodes.« less

  10. [Examination of patient dose reduction in cardiovasucular X-ray systems with a metal filter].

    PubMed

    Yasuda, Mitsuyoshi; Kato, Kyouichi; Tanabe, Nobuaki; Sakiyama, Koushi; Uchiyama, Yushi; Suzuki, Yoshiaki; Suzuki, Hiroshi; Nakazawa, Yasuo

    2012-01-01

    In interventional X-ray for cardiology of flat panel digital detector (FPD), the phenomenon that exposure dose was suddenly increased when a subject thickness was thickened was recognized. At that time, variable metal built-in filters in FPD were all off. Therefore, we examined whether dose reduction was possible without affecting a clinical image using metal filter (filter) which we have been conventionally using for dose reduction. About 45% dose reduction was achieved when we measured an exposure dose at 30 cm of acrylic thickness in the presence of a filter. In addition, we measured signal to noise ratio/contrast to noise ratio/a resolution limit by the visual evaluation, and there was no influence by filter usage. In the clinical examination, visual evaluation of image quality of coronary angiography (40 cases) using a 5-point evaluation scale by a physician was performed. As a result, filter usage did not influence the image quality (p=NS). Therefore, reduction of sudden increase of exposure dose was achieved without influencing an image quality by adding filter to FPD.

  11. Does carbon reduction increase sustainability? A study in wastewater treatment.

    PubMed

    Sweetapple, Christine; Fu, Guangtao; Butler, David

    2015-12-15

    This study investigates the relationships between carbon reduction and sustainability in the context of wastewater treatment, focussing on the impacts of control adjustments, and demonstrates that reducing energy use and/or increasing energy recovery to reduce net energy can be detrimental to sustainability. Factorial sampling is used to derive 315 control options, containing two different control strategies and a range of sludge wastage flow rates and dissolved oxygen setpoints, for evaluation. For each, sustainability indicators including operational costs, net energy and multiple environmental performance measures are calculated. This enables identification of trade-offs between different components of sustainability which must be considered before implementing energy reduction measures. In particular, it is found that the impacts of energy reduction measures on sludge production and nitrogen removal must be considered, as these are worsened in the lowest energy solutions. It also demonstrates that a sufficiently large range of indicators need to be assessed to capture trade-offs present within the environmental component of sustainability. This is because no solutions provided a move towards sustainability with respect to every indicator. Lastly, it is highlighted that improving the energy balance (as may be considered an approach to achieving carbon reduction) is not a reliable means of reducing total greenhouse gas emissions. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  12. Minimum fan turbine inlet temperature mode evaluation

    NASA Technical Reports Server (NTRS)

    Orme, John S.; Nobbs, Steven G.

    1995-01-01

    Measured reductions in turbine temperature which resulted from the application of the F-15 performance seeking control (PSC) minimum fan turbine inlet temperature (FTIT) mode during the dual-engine test phase is presented as a function of net propulsive force and flight condition. Data were collected at altitudes of 30,000 and 45,000 feet at military and partial afterburning power settings. The FTIT reductions for the supersonic tests are less than at subsonic Mach numbers because of the increased modeling and control complexity. In addition, the propulsion system was designed to be optimized at the mid supersonic Mach number range. Subsonically at military power, FTIT reductions were above 70 R for either the left or right engines, and repeatable for the right engine. At partial afterburner and supersonic conditions, the level of FTIT reductions were at least 25 R and as much as 55 R. Considering that the turbine operates at or very near its temperature limit at these high power settings, these seemingly small temperature reductions may significantly lengthen the life of the turbine. In general, the minimum FTIT mode has performed well, demonstrating significant temperature reductions at military and partial afterburner power. Decreases of over 100 R at cruise flight conditions were identified. Temperature reductions of this magnitude could significantly extend turbine life and reduce replacement costs.

  13. Investigation of Rotor Performance and Loads of a UH-60A Individual Blade Control System

    NASA Technical Reports Server (NTRS)

    Yeo, Hyeonsoo; Romander, Ethan A.; Norman, Thomas R.

    2011-01-01

    Wind tunnel measurements of performance, loads, and vibration of a full-scale UH-60A Black Hawk main rotor with an individual blade control (IBC) system are compared with calculations obtained using the comprehensive helicopter analysis CAMRAD II and a coupled CAMRAD II/OVERFLOW 2 analysis. Measured data show a 5.1% rotor power reduction (8.6% rotor lift to effective-drag ratio increase) using 2/rev IBC actuation with 2.0 amplitude at = 0.4. At the optimum IBC phase for rotor performance, IBC actuator force (pitch link force) decreased, and neither flap nor chord bending moments changed significantly. CAMRAD II predicts the rotor power variations with the IBC phase reasonably well at = 0.35. However, the correlation degrades at = 0.4. Coupled CAMRAD II/OVERFLOW 2 shows excellent correlation with the measured rotor power variations with the IBC phase at both = 0.35 and = 0.4. Maximum reduction of IBC actuator force is better predicted with CAMRAD II, but general trends are better captured with the coupled analysis. The correlation of vibratory hub loads is generally poor by both methods, although the coupled analysis somewhat captures general trends.

  14. Investigation of Rotor Performance and Loads of a UH-60A Individual Blade Control System

    NASA Technical Reports Server (NTRS)

    Yeo, Hyeonsoo; Romander, Ethan A.; Norman, Thomas R.

    2011-01-01

    Wind tunnel measurements of performance, loads, and vibration of a full-scale UH-60A Black Hawk main rotor with an individual blade control (IBC) system are compared with calculations obtained using the comprehensive helicopter analysis CAMRAD II and a coupled CAMRAD II/OVERFLOW 2 analysis. Measured data show a 5.1% rotor power reduction (8.6% rotor lift to effective-drag ratio increase) using 2/rev IBC actuation with 2.0. amplitude at u = 0.4. At the optimum IBC phase for rotor performance, IBC actuator force (pitch link force) decreased, and neither flap nor chord bending moments changed significantly. CAMRAD II predicts the rotor power variations with IBC phase reasonably well at u = 0.35. However, the correlation degrades at u = 0.4. Coupled CAMRAD II/OVERFLOW 2 shows excellent correlation with the measured rotor power variations with IBC phase at both u = 0.35 and u = 0.4. Maximum reduction of IBC actuator force is better predicted with CAMRAD II, but general trends are better captured with the coupled analysis. The correlation of vibratory hub loads is generally poor by both methods, although the coupled analysis somewhat captures general trends.

  15. Reduction in spread of excitation from current focusing at multiple cochlear locations in cochlear implant users.

    PubMed

    Padilla, Monica; Landsberger, David M

    2016-03-01

    Channel interaction from a broad spread of excitation is likely to be a limiting factor in performance by cochlear implant users. Although partial tripolar stimulation has been shown to reduce spread of excitation, the magnitude of the reduction is highly variable across subjects. Because the reduction in spread of excitation is typically only measured at one electrode for a given subject, the degree of variability across cochlear locations is unknown. The first goal of the present study was to determine if the reduction in spread of excitation observed from partial tripolar current focusing systematically varies across the cochlea. The second goal was to measure the variability in reduction of spread of excitation relative to monopolar stimulation across the cochlea. The third goal was to expand upon previous results that suggest that scaling of verbal descriptors can be used to predict the reduction in spread of excitation, by increasing the limited number of sites previously evaluated and verify the relationships remain with the larger dataset. The spread of excitation for monopolar and partial tripolar stimulation was measured at 5 cochlear locations using a psychophysical forward masking task. Results of the present study suggest that although partial tripolar stimulation typically reduces spread of excitation, the degree of reduction in spread of excitation was found to be highly variable and no effect of cochlear location was found. Additionally, subjective scaling of certain verbal descriptors (Clean/Dirty, Pure/Noisy) correlated with the reduction in spread of excitation suggesting sound quality scaling might be used as a quick clinical estimate of channels providing a reduction in spread of excitation. This quick scaling technique might help clinicians determine which patients would be most likely to benefit from a focused strategy. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Reduction in Spread of Excitation from Current Focusing at Multiple Cochlear Locations in Cochlear Implant Users

    PubMed Central

    Padilla, Monica; Landsberger, David M.

    2016-01-01

    Channel interaction from a broad spread of excitation is likely to be a limiting factor in performance by cochlear implant users. Although partial tripolar stimulation has been shown to reduce spread of excitation, the magnitude of the reduction is highly variable across subjects. Because the reduction in spread of excitation is typically only measured at one electrode for a given subject, the degree of variability across cochlear locations is unknown. The first goal of the present study was to determine if the reduction in spread of excitation observed from partial tripolar current focusing systematically varies across the cochlea. The second goal was to measure the variability in reduction of spread of excitation relative to monopolar stimulation across the cochlea. The third goal was to expand upon previous results that suggest that scaling of verbal descriptors can be used to predict the reduction in spread of excitation, by increasing the limited number of sites previously evaluated and verify the relationships remain with the larger dataset. The spread of excitation for monopolar and partial tripolar stimulation was measured at 5 cochlear locations using a psychophysical forward masking task. Results of the present study suggest that although partial tripolar stimulation typically reduces spread of excitation, the degree of reduction in spread of excitation was found to be highly variable and no effect of cochlear location was found. Additionally, subjective scaling of certain verbal descriptors (Clean/Dirty, Pure/Noisy) correlated with the reduction in spread of excitation suggesting sound quality scaling might be used as a quick clinical estimate of channels providing a reduction in spread of excitation. This quick scaling technique might help clinicians determine which patients would be most likely to benefit from a focused strategy. PMID:26778546

  17. Blood flow measurement in extracorporeal circulation using self-mixing laser diode

    NASA Astrophysics Data System (ADS)

    Cattini, Stefano; Norgia, Michele; Pesatori, Alessandro; Rovati, Luigi

    2010-02-01

    To measure blood flow rate in ex-vivo circulation, we propose an optical Doppler flowmeter based on the self-mixing effect within a laser diode (SM-LD). Advantages in adopting SM-LD techniques derive from reduced costs, ease of implementation and limited size. Moreover, the provided contactless sensing allows sensor reuse, hence further cost reduction. Preliminary measurements performed on bovine blood are reported, thus demonstrating the applicability of the proposed measurement method.

  18. Low cost and thin metasurface for ultra wide band and wide angle polarization insensitive radar cross section reduction

    NASA Astrophysics Data System (ADS)

    Ameri, Edris; Esmaeli, Seyed Hassan; Sedighy, Seyed Hassan

    2018-05-01

    A planar low cost and thin metasurface is proposed to achieve ultra-wideband radar cross section (RCS) reduction with stable performance with respect to polarization and incident angles. This metasurface is composed of two different artificial magnetic conductor unit cells arranged in a chessboard like configuration. These unit cells have a Jerusalem cross pattern with different thicknesses, which results in wideband out-phase reflection and RCS reduction, consequently. The designed metasurface reduces RCS more than 10-dB from 13.6 GHz to 45.5 GHz (108% bandwidth) and more than 20-dB RCS from 15.2 GHz to 43.6 GHz (96.6%). Moreover, the 10-dB RCS reduction bandwidth is very stable (more than 107%) for both TE and TM polarizations. The good agreement between simulations and measurement results proves the design, properly. The ultra-wide bandwidth, low cost, low profile, and stable performance of this metasurface prove its high capability compared with the state-of-the-art references.

  19. [Policies and innovation in mental healthcare: limits to decoupling from the performance of the SUS].

    PubMed

    Ribeiro, José Mendes; Inglez-Dias, Aline

    2011-12-01

    We studied Brazilian policies on mental health with respect to normative, supply and demand and financing aspects. We concluded that the sustainability of innovations in psychiatric reform depends on enhanced financing and integration with primary care community services, on the overall performance of SUS and the reduction of autonomous and exclusive services in primary care. There is high and rising pressure in demand for services measured in DALY and the incidence of disease. The reduction observed in psychiatric beds was accompanied by the systemic reduction, though with selective reduction for psychiatric hospitalizations. CAPS services have institutional limits due to the model adopted of direct public administration and local government capacity. Secondary data available show that: (i) SUS has a virtual monopoly on general outpatient and hospital services; (ii) mental health specialists belong mostly to SUS; (iii) most mental health services are outpatient services; (iv) few CAPS have day-bed services available; and (v) there is reduced federal financing for these innovations.

  20. Event-related potential evidence for the processing efficiency theory.

    PubMed

    Murray, N P; Janelle, C M

    2007-01-15

    The purpose of this study was to examine the central tenets of the processing efficiency theory using psychophysiological measures of attention and effort. Twenty-eight participants were divided equally into either a high or low trait anxiety group. They were then required to perform a simulated driving task while responding to one of four target light-emitting diodes. Cortical activity and dual task performance were recorded under two conditions -- baseline and competition -- with cognitive anxiety being elevated in the competitive session by an instructional set. Although driving speed was similar across sessions, a reduction in P3 amplitude to cue onset in the light detection task occurred for both groups during the competitive session, suggesting a reduction in processing efficiency as participants became more state anxious. Our findings provide more comprehensive and mechanistic evidence for processing efficiency theory, and confirm that increases in cognitive anxiety can result in a reduction of processing efficiency with little change in performance effectiveness.

  1. Effect of surfactants and temperature on the hyperfiltration performance of poly(ether/urea) membranes

    NASA Technical Reports Server (NTRS)

    Leban, M. I.; Wydeven, T. J.

    1984-01-01

    The individual and combined effects of pasteurization temperature (347 K) and surfactants (anionic, cationic, and neutral) on a poly(ether/urea) thin-film hyperfiltration membrane were studied. Performance of this positively charged membrane was measured in terms of sodium chloride rejection and water flux. The observed effect was mostly on water flux and minimal on salt rejection. Pasteurization temperature caused an irreversible flux decline (flux decline slope of 0.09). The gradual flux reduction caused by neutral and cationic surfactants was reversible, whereas the flux reduction caused by anionic surfactant was irreversible and of similar magnitude to flux reduction caused by pasteurization temperature. The effects of anionic surfactant and pasteurization temperature were additive. Because of flux decline at elevated temperatures the poly(ether/urea) membrane is not very attractive for long-term spaceflight use.

  2. Comparing and contrasting poverty reduction performance of social welfare programs across jurisdictions in Canada using Data Envelopment Analysis (DEA): an exploratory study of the era of devolution.

    PubMed

    Habibov, Nazim N; Fan, Lida

    2010-11-01

    In the mid-1990s, the responsibilities to design, implement, and evaluate social welfare programs were transferred from federal to local jurisdictions in many countries of North America and Europe through devolution processes. Devolution has caused the need for a technique to measure and compare the performances of social welfare programs across multiple jurisdictions. This paper utilizes Data Envelopment Analysis (DEA) for a comparison of poverty reduction performances of jurisdictional social welfare programs across Canadian provinces. From the theoretical perspective, findings of this paper demonstrates that DEA is a promising method to evaluate, compare, and benchmark poverty reduction performance across multiple jurisdictions using multiple inputs and outputs. This paper demonstrates that DEA generates easy to comprehend composite rankings of provincial performances, identifies appropriate benchmarks for each inefficient province, and estimates sources and amounts of improvement needed to make the provinces efficient. From a practical perspective the empirical results presented in this paper indicate that Newfoundland, Prince Edwards Island, and Alberta achieve better efficiency in poverty reduction than other provinces. Policy makers and social administrators of the ineffective provinces across Canada may find benefit in selecting one of the effective provinces as a benchmark for improving their own performance based on similar size and structure of population, size of the budget for social programs, and traditions with administering particular types of social programs. Copyright (c) 2009 Elsevier Ltd. All rights reserved.

  3. Refurbishment of a Victorian terraced house for energy efficiency

    NASA Astrophysics Data System (ADS)

    Dimitriou, Angeliki

    The impacts of global warming are now obvious. The international community has committed itself to reduce CO2 emissions, the main contributor to the greenhouse effect, both at international and national levels. In the Kyoto Protocol signed in 1997, countries have committed to reduce their greenhouse gases emissions below their 1990 levels by the period 2008-2012. The UK specifically should reduce those emissions by 12.5%. Format reason, the UK has introduced a package of policies, which promote not only the use of renewable energy resources, but most importantly the reduction in energy use, with energy efficiency. Refurbishment of existing houses has and will contribute to the reduction of energy consumption. A Victorian mid-terraced house was studied in this report, and different refurbishment measures were tested, using two software programmes: TAS and SAP. The targets were to achieve certain levels of thermal comfort, to comply with the Building Regulation for building thermal elements and to achieve a high SAP rating. Then, the cost of each measure was calculated and its CO2 emissions were compared. Heat losses were mainly through the walls and roof. Roof and mainly wall refurbishment measures reduce the heating loads the most. Ground floor insulation does not contribute to the reduction of the heating loads, on the contrary it has detrimental effect in summer, where the cooling effect coming from the ground is being reduced. Window replacement achieves a very good performance in summer resulting in the reduction of overheating. Wall and roof insulation increase the SAP rating the most, between the building elements, but boiler replacement and upgrading of heating controls increase it more. According to the SAP rating, CO2 annual emissions are reduced the most by boiler replacement and then by wall and roof. The results given by the two softwares concerning which measure is more leads more to energy efficiency, are the same. Finally, if the measures which lead to the best energy performance are combined together, then the house could cut its energy bills by half, and could have 70% reduction in CO2 emissions.

  4. Impact of hemodialysis on dual X-ray absorptiometry, bioelectrical impedance measurements, and anthropometry.

    PubMed

    Abrahamsen, B; Hansen, T B; Høgsberg, I M; Pedersen, F B; Beck-Nielsen, H

    1996-01-01

    Dual X-ray absorptiometry (DXA) performs noninvasive assessment of bone and soft tissue with high precision. However, soft tissue algorithms assume that 73.2% of the lean body mass is water, a potential source of error in fluid retention. We evaluated DXA (model QDR-2000; Hologic Inc, Waltham, MA), bioelectrical impedance analysis (BIA), and simple anthropometry in 19 patients (9 women and 10 men, mean age 46 y) before and after hemodialysis, removing 0.9-4.3 L (x: 2.8L) of ultrafiltrate. The reduction in fat-free mass (FFM) measured by DXA was highly correlated with the ultrafiltrate, as determined by the reduction in gravimetric weight (r = 0.975, P < 0.0001; SEE: 233 g), whereas BIA was considerably less accurate in assessing FFM reductions (r = 0.66, P < 0.01; SEE: 757 g). Lumbar bone mineral density (BMD) was unaffected by dialysis, as were whole-body fat and BMD. Whole-body bone mineral content, however, was estimated to be 0.6% lower after dialysis. None of the simple anthropometric measurements correlated significantly with the reduction in FFM. In an unmodified clinical setting, DXA appears to be superior to other simple noninvasive methods for determining body composition, particularly when the emphasis is on repeated measurements.

  5. Data reduction procedures for traffic signal systems performance measures.

    DOT National Transportation Integrated Search

    2011-01-01

    Traffic signal systems represent a substantial component of the highway transportation network in the United States. It is challenging for most agencies to find engineering resources to properly update signal policies and timing plans to accommodate ...

  6. Stop and revive? The effectiveness of nap and active rest breaks for reducing driver sleepiness.

    PubMed

    Watling, Christopher N; Smith, Simon S; Horswill, Mark S

    2014-11-01

    The purpose of this study was to compare the effects of two commonly utilized sleepiness countermeasures: a nap break and an active rest break. The effects of the countermeasures were evaluated by physiological (EEG), subjective, and driving performance measures. Participants completed 2 h of simulated driving, followed by a 15-min nap break or a 15-min active rest break, then completed the final hour of simulated driving. The nap break reduced EEG and subjective sleepiness. The active rest break did not reduce EEG sleepiness, with sleepiness levels eventually increasing, and resulted in an immediate reduction of subjective sleepiness. No difference was found between the two breaks for the driving performance measure. The immediate reduction of subjective sleepiness after the active rest break could leave drivers with erroneous perceptions of their sleepiness, particularly with increases of physiological sleepiness after the break. Copyright © 2014 Society for Psychophysiological Research.

  7. 40 CFR Table 18 to Subpart Uuu of... - Requirements for Performance Tests for Organic HAP Emissions From Catalytic Reforming Units

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... part 60, appendix A), as applicable c. Measure TOC concentration (for percent reduction standard) Method 25 (40 part 60, appendix A) to measure nonmethane TOC concentration (in carbon equivalents) at inlet and outlet of the control device. If the nonmethane TOC outlet concentration is expected to be...

  8. Onboard Acoustic Data-Processing for the Statistical Analysis of Array Beam-Noise,

    DTIC Science & Technology

    1980-12-15

    performance of the sonar system as a measurement tool and others that can assess the character of the ambient- noise field at the time of the measurement. In...the plot as would "dead" hydrophones. A reduction in sensitivity of a hydrophone, a faulty preamplifier , or any other fault in the acoustic channel

  9. Herd-specific interventions to reduce antimicrobial usage in pig production without jeopardising technical and economic performance.

    PubMed

    Collineau, L; Rojo-Gimeno, C; Léger, A; Backhans, A; Loesken, S; Nielsen, E Okholm; Postma, M; Emanuelson, U; Beilage, E Grosse; Sjölund, M; Wauters, E; Stärk, K D C; Dewulf, J; Belloc, C; Krebs, S

    2017-09-01

    Pig farmers are strongly encouraged to reduce their antimicrobial usage in order to reduce the risk of antimicrobial resistance. Herd-level intervention is needed to achieve national and European reduction targets. Alternative, especially preventive measures, have to be implemented to reduce the need for antimicrobial treatments. However, little is known about the feasibility, effectiveness and return on investment of such measures. The objective of this study was to assess, across four countries, the technical and economic impact of herd-specific interventions aiming at reducing antimicrobial usage in pig production while implementing alternative measures. An intervention study was conducted between February 2014 and August 2015 in 70 farrow-to-finish pig farms located in Belgium, France, Germany and Sweden. Herd-specific interventions were defined together with the farmer and the herd veterinarian. Farms were followed over one year and their antimicrobial usage and technical performance were compared with values from the year before intervention. Compliance with the intervention plan was also monitored. Changes in margin over feed cost and net farm profit were estimated in a subset of 33 Belgian and French farms with sufficient data, using deterministic and stochastic modeling. Following interventions, a substantial reduction in antimicrobial use was achieved without negative impact the overall farm technical performance. A median reduction of 47.0% of antimicrobial usage was achieved across four countries when expressed in terms of treatment incidence from birth to slaughter, corresponding to a 30.5% median reduction of antimicrobial expenditures. Farm compliance with intervention plans was high (median: 93%; min-max: 20; 100) and farms with higher compliance tended to achieve bigger reduction (ρ=-0.18, p=0.162). No association was found between achieved reduction and type or number of alternative measures implemented. Mortality in suckling piglets, weaners and fatteners, daily weight gain and feed conversion ratio did not significantly change over the course of the study, while the number of weaned piglets per sow per year slightly increased. The median change in net farm profit among Belgian and French farms was estimated to be €4.46 (Q25-Q75:-32.54; 80.50) and €1.23 (Q25-Q75:-32.55; 74.45) per sow per year using the detererministic and stochastic models, respectively. It was more influenced by a change in feed conversion ratio and daily weight gain than by a change in antimicrobial expenditures or intervention direct net cost. Therefore, costs of alternative measures should not be perceived as a barrier, but rather as an opportunity to optimise production practices for sustained productivity and improved animal health. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. CT volumetry can potentially predict the local stage for gastric cancer after chemotherapy

    PubMed Central

    Wang, Zhi-Cong; Wang, Chen; Ding, Ying; Ji, Yuan; Zeng, Meng-Su; Rao, Sheng-Xiang

    2017-01-01

    PURPOSE We aimed to evaluate the value of CT tumor volumetry for predicting T and N stages of gastric cancer after chemotherapy, with pathologic results as the reference standard. METHODS This study retrospectively evaluated 42 patients diagnosed with gastric cancer, who underwent chemotherapy followed by surgery. Pre- and post-treatment CT tumor volumes (VT) were measured in portal venous phase and volume reduction ratios were calculated. Correlations between pre- and post-treatment VT, reduction ratio, and pathologic stages were analyzed. Receiver operator characteristic (ROC) analyses were also performed to assess diagnostic performance for prediction of downstaging to T0–2 stage and N0 stage. RESULTS Pretreatment VT, post-treatment VT, and VT reduction ratio were significantly correlated with T stage (rs=0.329, rs=0.546, rs= −0.422, respectively). Post-treatment VT and VT reduction ratio were significantly correlated with N stage (rs=0.442 and rs= −0.376, respectively). Pretreatment VT, post-treatment VT, and VT reduction ratio were significantly different between T0–2 and T3,4 stage tumors (P = 0.05, P < 0.001, and P = 0.002, respectively). The differences between N0 and ≥N1 groups were also statistically significant (P = 0.005 for post-treatment VT, P = 0.016 for VT reduction ratio, respectively). The area under the ROC curve (AUC) for identification of T0–2 groups was 0.70 for pretreatment VT, 0.88 for post-treatment VT, and 0.82 for VT reduction ratio, respectively. AUC was 0.78 for post-treatment VT and 0.74 for VT reduction ratio for identification of N0 groups. CONCLUSION CT tumor volumetry, particularly post-treatment measurement of VT, is potentially valuable for predicting histopathologic T and N stages after chemotherapy in patients with gastric cancer. PMID:28703101

  11. Net reclassification index at event rate: properties and relationships.

    PubMed

    Pencina, Michael J; Steyerberg, Ewout W; D'Agostino, Ralph B

    2017-12-10

    The net reclassification improvement (NRI) is an attractively simple summary measure quantifying improvement in performance because of addition of new risk marker(s) to a prediction model. Originally proposed for settings with well-established classification thresholds, it quickly extended into applications with no thresholds in common use. Here we aim to explore properties of the NRI at event rate. We express this NRI as a difference in performance measures for the new versus old model and show that the quantity underlying this difference is related to several global as well as decision analytic measures of model performance. It maximizes the relative utility (standardized net benefit) across all classification thresholds and can be viewed as the Kolmogorov-Smirnov distance between the distributions of risk among events and non-events. It can be expressed as a special case of the continuous NRI, measuring reclassification from the 'null' model with no predictors. It is also a criterion based on the value of information and quantifies the reduction in expected regret for a given regret function, casting the NRI at event rate as a measure of incremental reduction in expected regret. More generally, we find it informative to present plots of standardized net benefit/relative utility for the new versus old model across the domain of classification thresholds. Then, these plots can be summarized with their maximum values, and the increment in model performance can be described by the NRI at event rate. We provide theoretical examples and a clinical application on the evaluation of prognostic biomarkers for atrial fibrillation. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  12. Functional Task Test: 3. Skeletal Muscle Performance Adaptations to Space Flight

    NASA Technical Reports Server (NTRS)

    Ryder, Jeffrey W.; Wickwire, P. J.; Buxton, R. E.; Bloomberg, J. J.; Ploutz-Snyder, L.

    2011-01-01

    The functional task test is a multi-disciplinary study investigating how space-flight induced changes to physiological systems impacts functional task performance. Impairment of neuromuscular function would be expected to negatively affect functional performance of crewmembers following exposure to microgravity. This presentation reports the results for muscle performance testing in crewmembers. Functional task performance will be presented in the abstract "Functional Task Test 1: sensory motor adaptations associated with postflight alternations in astronaut functional task performance." METHODS: Muscle performance measures were obtained in crewmembers before and after short-duration space flight aboard the Space Shuttle and long-duration International Space Station (ISS) missions. The battery of muscle performance tests included leg press and bench press measures of isometric force, isotonic power and total work. Knee extension was used for the measurement of central activation and maximal isometric force. Upper and lower body force steadiness control were measured on the bench press and knee extension machine, respectively. Tests were implemented 60 and 30 days before launch, on landing day (Shuttle crew only), and 6, 10 and 30 days after landing. Seven Space Shuttle crew and four ISS crew have completed the muscle performance testing to date. RESULTS: Preliminary results for Space Shuttle crew reveal significant reductions in the leg press performance metrics of maximal isometric force, power and total work on R+0 (p<0.05). Bench press total work was also significantly impaired, although maximal isometric force and power were not significantly affected. No changes were noted for measurements of central activation or force steadiness. Results for ISS crew were not analyzed due to the current small sample size. DISCUSSION: Significant reductions in lower body muscle performance metrics were observed in returning Shuttle crew and these adaptations are likely contributors to impaired functional tasks that are ambulatory in nature (See abstract Functional Task Test: 1). Interestingly, no significant changes in central activation capacity were detected. Therefore, impairments in muscle function in response to short-duration space flight are likely myocellular rather than neuromotor in nature.

  13. Reduction of the Buildup Contribution in Gamma Ray Attenuation Measurements and a New Way to Study This Experiment in a Student Laboratory

    ERIC Educational Resources Information Center

    Adamides, E.; Kavadjiklis, A.; Koutroubas, S.K.; Moshonas, N.; Tzedakis, A.; Yiasemides, K.

    2014-01-01

    In continuation of our investigation into the buildup phenomenon appearing in gamma ray attenuation measurements in laboratory experiments we study the dependence of the buildup factor on the area of the absorber in an effort to reduce the buildup of photons. Detailed measurements are performed for up to two mean free paths of [superscript 60]Co…

  14. Intelligent Control for Drag Reduction on the X-48B Vehicle

    NASA Technical Reports Server (NTRS)

    Griffin, Brian Joseph; Brown, Nelson Andrew; Yoo, Seung Yeun

    2011-01-01

    This paper focuses on the development of an intelligent control technology for in-flight drag reduction. The system is integrated with and demonstrated on the full X-48B nonlinear simulation. The intelligent control system utilizes a peak-seeking control method implemented with a time-varying Kalman filter. Performance functional coordinate and magnitude measurements, or independent and dependent parameters respectively, are used by the Kalman filter to provide the system with gradient estimates of the designed performance function which is used to drive the system toward a local minimum in a steepestdescent approach. To ensure ease of integration and algorithm performance, a single-input single-output approach was chosen. The framework, specific implementation considerations, simulation results, and flight feasibility issues related to this platform are discussed.

  15. How Well Does Dual-Energy Computed Tomography With Metal Artifact Reduction Software Improve Image Quality and Quantify Computed Tomography Number and Iodine Concentration?

    PubMed

    Ohira, Shingo; Kanayama, Naoyuki; Wada, Kentaro; Karino, Tsukasa; Nitta, Yuya; Ueda, Yoshihiro; Miyazaki, Masayoshi; Koizumi, Masahiko; Teshima, Teruki

    2018-04-02

    The objective of this study was to assess the accuracy of the quantitative measurements obtained using dual-energy computed tomography with metal artifact reduction software (MARS). Dual-energy computed tomography scans (fast kV-switching) are performed on a phantom, by varying the number of metal rods (Ti and Pb) and reference iodine materials. Objective and subjective image analyses are performed on retroreconstructed virtual monochromatic images (VMIs) (VMI at 70 keV). The maximum artifact indices for VMI-Ti and VMI-Pb (5 metal rods) with MARS (without MARS) were 17.4 (166.7) and 34.6 (810.6), respectively; MARS significantly improved the mean subjective 5-point score (P < 0.05). The maximum differences between the measured Hounsfield unit and theoretical values for 5 mg/mL iodine and 2-mm core rods were -42.2% and -68.5%, for VMI-Ti and VMI-Pb (5 metal rods), respectively, and the corresponding differences in the iodine concentration were -64.7% and -73.0%, respectively. Metal artifact reduction software improved the objective and subjective image quality; however, the quantitative values were underestimated.

  16. Effect of Surface Roughness on Polymer Drag Reduction with a High-Reynolds-Number Turbulent Boundary Layer

    NASA Astrophysics Data System (ADS)

    Elbing, Brian; Dowling, David; Solomon, Michael; Bian, Sherry; Ceccio, Steven

    2007-11-01

    A recent experiment at the U.S. Navy's Large Cavitation Channel (LCC) investigated the effect of wall roughness on wall-injection polymer drag reduction (PDR) within a high-Reynolds-number (10^7 to 2x10^8 based on downstream distance) turbulent boundary layer (TBL). Testing was performed in two parts: 1) PDR experiment on a 12.9 m long, 3.05 m wide hydro-dynamically smooth flat plate and 2) PDR experiment on the same model with the entire surface roughened. The roughness was produced by blowing glass beads into epoxy paint that was applied to the entire model. The roughened model had an average roughness height ranging between 307 and 1154 μm. Drag reduction was determined using six, stream-wise located integrated skin-friction balances. In addition to skin-friction measurements, sampling was performed at three stream-wise located ports. The sampling ports were used to determine the amount of degradation, if any, caused by the turbulent flow on the polymer. Both the skin-friction measurements and sampling analysis indicates that wall roughness in a turbulent boundary layer significantly increases degradation of the polymer solution.

  17. Gum-compliant uncertainty propagations for Pu and U concentration measurements using the 1st-prototype XOS/LANL hiRX instrument; an SRNL H-Canyon Test Bed performance evaluation project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holland, Michael K.; O'Rourke, Patrick E.

    An SRNL H-Canyon Test Bed performance evaluation project was completed jointly by SRNL and LANL on a prototype monochromatic energy dispersive x-ray fluorescence instrument, the hiRX. A series of uncertainty propagations were generated based upon plutonium and uranium measurements performed using the alpha-prototype hiRX instrument. Data reduction and uncertainty modeling provided in this report were performed by the SRNL authors. Observations and lessons learned from this evaluation were also used to predict the expected uncertainties that should be achievable at multiple plutonium and uranium concentration levels provided instrument hardware and software upgrades being recommended by LANL and SRNL are performed.

  18. Access to Care Under Physician Payment Reform: A Physician-Based Analysis

    PubMed Central

    Meadow, Ann

    1995-01-01

    This article reports physician-based measures of access to care during the 3 years surrounding the 1989 physician payment reforms. Analysis was facilitated by a new system of physician identifiers in Medicare claims. Access measures include caseload per physician and related measures of the demographic composition of physicians' clientele, the proportion of physicians performing surgical and other procedures, and the assignment rate. The caseload and assignment measures were stable or improving over time, suggesting that reforms did not harm access. Procedure performance rates tended to decline between 1992 and 1993, but reductions were inversely related to the estimated fee changes, and several may be explainable by other factors. PMID:10172615

  19. Gonadotrophin-releasing hormone agonist treatment for sexual offenders: A systematic review.

    PubMed

    Lewis, Alexandra; Grubin, Don; Ross, Callum C; Das, Mrigendra

    2017-10-01

    Sexual offending is a significant international issue causing long-term consequences for victims, perpetrators and society. The purpose of this study was to review the existing research data assessing the efficacy of gonadotrophin-releasing hormone agonists for treating adult, male, sexual offenders. The method of this review involved the examination of studies involving participants prescribed at least one month of a gonadotrophin-releasing hormone agonist for the purposes of reducing sexual drive related to offending. The primary outcome measures were recidivism rates and sexual functioning. Secondary outcome measures included assessment of side effects and effects on interpersonal/psychiatric functioning. Studies in the English language that were dated 1969-2015 were included. Twelve eligible studies (323 participants) were identified. A reduction in a variety of measures of sexual functioning and/or risk was found in all studies. Robust recidivism data was limited. Medication was rarely described as ineffectual. All studies reported side effects. Reduction in bone density and potential long-term reduction in fertility in some subjects were issues of concern. Whilst identified studies showed promising results with respect to sexual functioning, challenges in performing randomised control trials in this subject group meant that included studies were methodologically limited. This review recommends that future research must be performed before the effectiveness and tolerability of gonadotrophin-releasing hormone agonists in this population can be confirmed.

  20. A Preliminary Evaluation of a School-Based Media Education and Reduction Intervention.

    PubMed

    Bickham, David S; Hswen, Yulin; Slaby, Ronald G; Rich, Michael

    2018-06-01

    While media education and reduction programs have been proposed to prevent adverse health and academic outcomes related to heavy electronic media use among school-aged children, few have been formally piloted and evaluated. We used a quasi-experimental design to evaluate the effectiveness of Take the Challenge (TtC), a school-based media education/reduction program for the primary prevention of sleep deprivation, dysfunctional social-emotional behaviors, and poor academic performance. Sixth- to eighth-grade students at a rural Midwestern U.S. middle school received the TtC program, while a similar school in the same district served as the comparison group. Health-related and academic measures were collected from students and teachers at both schools before and after the intervention. The primary outcome measure was student-reported electronic media use (television, video games, Internet). Secondary measures included student health behaviors (student-reported sleep, exercise, and outdoor play) and academic activities (teacher-reported homework and classroom performance). Compared to the comparison group, students receiving TtC slept more and reduced television viewing, background television time, after-school video gaming, and weekend Internet use. Teachers reported increases in the extent to which TtC students completed homework assignments and stayed on task in the classroom. Well-designed school-based programs such as TtC can reduce electronic media use among middle-school children and improve related health and academic outcomes.

  1. Influence of radiofrequency surgery on architecture of the palatine tonsils.

    PubMed

    Plzak, Jan; Macokova, Pavla; Zabrodsky, Michal; Kastner, Jan; Lastuvka, Petr; Astl, Jaromir

    2014-01-01

    Radiofrequency surgery is a widely used modern technique for submucosal volume reduction of the tonsils. So far there is very limited information on morphologic changes in the human tonsils after radiofrequency surgery. We performed histopathological study of tonsillectomy specimens after previous bipolar radiofrequency induced thermotherapy (RFITT). A total of 83 patients underwent bipolar RFITT for hypertrophy of palatine tonsils. Tonsil volume reduction was measured by 3D ultrasonography. Five patients subsequently underwent tonsillectomy. Profound histopathological examination was performed to determine the effect of RFITT on tonsillar architecture. All tonsillectomy specimens showed the intact epithelium, intact germinal centers, normal vascularization, and no evidence of increased fibrosis. No microscopic morphological changes in tonsillectomy specimens after bipolar RFITT were observed. RFITT is an effective submucosal volume reduction procedure for treatment of hypertrophic palatine tonsils with no destructive effect on microscopic tonsillar architecture and hence most probably no functional adverse effect.

  2. Dynamic test/analysis correlation using reduced analytical models

    NASA Technical Reports Server (NTRS)

    Mcgowan, Paul E.; Angelucci, A. Filippo; Javeed, Mehzad

    1992-01-01

    Test/analysis correlation is an important aspect of the verification of analysis models which are used to predict on-orbit response characteristics of large space structures. This paper presents results of a study using reduced analysis models for performing dynamic test/analysis correlation. The reduced test-analysis model (TAM) has the same number and orientation of DOF as the test measurements. Two reduction methods, static (Guyan) reduction and the Improved Reduced System (IRS) reduction, are applied to the test/analysis correlation of a laboratory truss structure. Simulated test results and modal test data are used to examine the performance of each method. It is shown that selection of DOF to be retained in the TAM is critical when large structural masses are involved. In addition, the use of modal test results may provide difficulties in TAM accuracy even if a large number of DOF are retained in the TAM.

  3. Disturbance Reduction Control Design for the ST7 Flight Validation Experiment

    NASA Technical Reports Server (NTRS)

    Maghami, P. G.; Hsu, O. C.; Markley, F. L.; Houghton, M. B.

    2003-01-01

    The Space Technology 7 experiment will perform an on-orbit system-level validation of two specific Disturbance Reduction System technologies: a gravitational reference sensor employing a free-floating test mass, and a set of micro-Newton colloidal thrusters. The ST7 Disturbance Reduction System is designed to maintain the spacecraft's position with respect to a free-floating test mass to less than 10 nm/Hz, over the frequency range of 1 to 30 mHz. This paper presents the design and analysis of the coupled, drag-free and attitude control systems that close the loop between the gravitational reference sensor and the micro-Newton thrusters, while incorporating star tracker data at low frequencies. A full 18 degree-of-freedom model, which incorporates rigid-body models of the spacecraft and two test masses, is used to evaluate the effects of actuation and measurement noise and disturbances on the performance of the drag-free system.

  4. Relationship among food-safety knowledge, beliefs, and risk-reduction behavior in university students in Japan.

    PubMed

    Takeda, Sayaka; Akamatsu, Rie; Horiguchi, Itsuko; Marui, Eiji

    2011-01-01

    To identify whether university students who have both food-safety knowledge and beliefs perform risk-reduction behaviors. Cross-sectional research using a questionnaire that included food-safety knowledge, perceptions, risk-reduction behavior, stages for the selection of safer food based on the Transtheoretical Model, and demographic characteristics. Four universities in eastern Japan and 2 universities in western Japan. University students (n = 799). Food-safety knowledge, beliefs, and risk-reduction behaviors. Answers on measures assessing risk perception and food-safety knowledge were combined to form 4 groups of participants. Relationships among demographic characteristics, the 4 groups, risk-reduction behaviors, stage of change, and severity and susceptibility were assessed. The proportion of students who had more knowledge of food safety and a belief that "there are no 100% safe food items" was high in the group that frequently performed risk-reduction behaviors, as it was in the group who had taken a basic class about food or health care and who had, or were working toward, a food or nutrition qualification. University students who thought that there were no 100% safe food items and who had more knowledge about food safety were more likely to confirm food-safety information when selecting food. Copyright © 2011 Society for Nutrition Education and Behavior. Published by Elsevier Inc. All rights reserved.

  5. A star-and-sky chopping polarimeter - Design and performance

    NASA Astrophysics Data System (ADS)

    Jain, S. K.; Srinivasulu, G.

    1991-09-01

    A star-and-sky chopping polarimeter is developed for accurate measurements of linear polarization of starlight in the standard astronomical photometric U, B, V, R, and I bands. The instrumental polarization, as determined by observing the standard unpolarized stars, is 0.04 percent. It is possible to use the instrument for the measurements of circular polarization as well. A Unicorn microcomputer controls the various operations of the instrument, acquires the data, and does the on-line data reduction. This paper describes the design and performance of the polarimeter.

  6. Reduction in trunk fat predicts cardiovascular exercise training-related reductions in C-reactive protein.

    PubMed

    Vieira, V J; Hu, L; Valentine, R J; McAuley, E; Evans, E M; Baynard, T; Woods, J A

    2009-05-01

    C-reactive protein (CRP) is an independent risk factor for cardiovascular disease. We sought to determine (1) if 10 months of cardiovascular exercise training (Cardio) reduces CRP in a group of older adults, (2) if such a reduction is related to improvements in trunk fat, fitness, and/or psychosocial variables, and (3) if the effect of Cardio on CRP differs between men and women. Community-dwelling residents (n=127; 60-83 yrs) were randomized to a Flex group (n=61) where they participated in 2-75 min supervised sessions per wk during which they performed non-cardiovascular flexibility and balance exercises or a Cardio group (n=66) where they participated in three supervised sessions per wk during which they performed cardiovascular exercises for approximately 45-60 min at 60-70% maximal oxygen uptake. The main outcome measures were serum CRP, cardiovascular fitness, total and central adiposity, and self-reported psychosocial function. Cardio experienced a reduction in CRP (-0.5mg/L), as well as improvements in fitness (+7%) and total (-1.5%) and central (i.e., trunk) (-2.5%) adiposity. These relationships were not modified by sex. Regression analyses indicated that only the reduction in trunk fat was significantly related to the reduction in CRP. Ten months of cardiovascular exercise training reduced CRP in previously sedentary older adults and this effect was partially mediated by a reduction in trunk fat.

  7. Environmental performance of green building code and certification systems.

    PubMed

    Suh, Sangwon; Tomar, Shivira; Leighton, Matthew; Kneifel, Joshua

    2014-01-01

    We examined the potential life-cycle environmental impact reduction of three green building code and certification (GBCC) systems: LEED, ASHRAE 189.1, and IgCC. A recently completed whole-building life cycle assessment (LCA) database of NIST was applied to a prototype building model specification by NREL. TRACI 2.0 of EPA was used for life cycle impact assessment (LCIA). The results showed that the baseline building model generates about 18 thousand metric tons CO2-equiv. of greenhouse gases (GHGs) and consumes 6 terajoule (TJ) of primary energy and 328 million liter of water over its life-cycle. Overall, GBCC-compliant building models generated 0% to 25% less environmental impacts than the baseline case (average 14% reduction). The largest reductions were associated with acidification (25%), human health-respiratory (24%), and global warming (GW) (22%), while no reductions were observed for ozone layer depletion (OD) and land use (LU). The performances of the three GBCC-compliant building models measured in life-cycle impact reduction were comparable. A sensitivity analysis showed that the comparative results were reasonably robust, although some results were relatively sensitive to the behavioral parameters, including employee transportation and purchased electricity during the occupancy phase (average sensitivity coefficients 0.26-0.29).

  8. Error reduction by combining strapdown inertial measurement units in a baseball stitch

    NASA Astrophysics Data System (ADS)

    Tracy, Leah

    A poor musical performance is rarely due to an inferior instrument. When a device is under performing, the temptation is to find a better device or a new technology to achieve performance objectives; however, another solution may be improving how existing technology is used through a better understanding of device characteristics, i.e., learning to play the instrument better. This thesis explores improving position and attitude estimates of inertial navigation systems (INS) through an understanding of inertial sensor errors, manipulating inertial measurement units (IMUs) to reduce that error and multisensor fusion of multiple IMUs to reduce error in a GPS denied environment.

  9. Composition, stability, and measurement of reduced uranium phases for groundwater bioremediation at Old Rifle, CO

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Campbell, K. M.; Davis, J. A.; Bargar, J.

    2011-10-15

    Reductive biostimulation is currently being explored as a possible remediation strategy for uranium (U) contaminated groundwater, and is currently being investigated at a field site in Rifle, CO, USA. The long-term stability of the resulting U(IV) phases is a key component of the overall performance and depends upon a variety of factors, including rate and mechanism of reduction, mineral associations in the subsurface, and propensity for oxidation. To address these factors, several approaches were used to evaluate the redox sensitivity of U: measurement of the rate of oxidative dissolution of biogenic uraninite (UO{sub 2(s)}) deployed in groundwater at Rifle, characterizationmore » of a zone of natural bioreduction exhibiting relevant reduced mineral phases, and laboratory studies of the oxidative capacity of Fe(III) and reductive capacity of Fe(II) with regard to U(IV) and U(VI), respectively.« less

  10. Spectral OCT with speckle contrast reduction for evaluation of the healing process after PRK and transepithelial PRK.

    PubMed

    Kaluzny, Bartlomiej J; Szkulmowski, Maciej; Bukowska, Danuta M; Wojtkowski, Maciej

    2014-04-01

    We evaluate Spectral OCT (SOCT) with a speckle contrast reduction technique using resonant scanner for assessment of corneal surface changes after excimer laser photorefractive keratectomy (PRK) and we compare healing process between conventional PRK and transepithelial PRK. The measurements were performed before and after the surgery. Obtained results show that SOCT with a resonant scanner speckle contrast reduction is capable of providing information regarding the healing process after PRK. The main difference between the healing processes of PRK and TransPRK, assessed by SOCT, was the time to cover the stroma with epithelium, which was shorter in the TransPRK group.

  11. Development and Applications of a Self-Contained, Non-Invasive EVA Joint Angle and Muscle Fatigue Sensor System

    NASA Technical Reports Server (NTRS)

    Ranniger, C. U.; Sorenson, E. A.; Akin, D. L.

    1995-01-01

    The University of Maryland Space Systems Laboratory, as a participant in NASA's INSTEP program, is developing a non-invasive, self-contained sensor system which can provide quantitative measurements of joint angles and muscle fatigue in the hand and forearm. The goal of this project is to develop a system with which hand/forearm motion and fatigue metrics can be determined in various terrestrial and zero-G work environments. A preliminary study of the prototype sensor systems and data reduction techniques for the fatigue measurement system are presented. The sensor systems evaluated include fiberoptics, used to measure joint angle, surface electrodes, which measure the electrical signals created in muscle as it contracts; microphones, which measure the noise made by contracting muscle; and accelerometers, which measure the lateral muscle acceleration during contraction. The prototype sensor systems were used to monitor joint motion of the metacarpophalangeal joint and muscle fatigue in flexor digitorum superficialis and flexor carpi ulnaris in subjects performing gripping tasks. Subjects were asked to sustain a 60-second constant-contraction (isometric) exercise and subsequently to perform a repetitive handgripping task to failure. Comparison of the electrical and mechanical signals of the muscles during the different tasks will be used to evaluate the applicability of muscle signal measurement techniques developed for isometric contraction tasks to fatigue prediction in quasi-dynamic exercises. Potential data reduction schemes are presented.

  12. The VIRUS data reduction pipeline

    NASA Astrophysics Data System (ADS)

    Goessl, Claus A.; Drory, Niv; Relke, Helena; Gebhardt, Karl; Grupp, Frank; Hill, Gary; Hopp, Ulrich; Köhler, Ralf; MacQueen, Phillip

    2006-06-01

    The Hobby-Eberly Telescope Dark Energy Experiment (HETDEX) will measure baryonic acoustic oscillations, first discovered in the Cosmic Microwave Background (CMB), to constrain the nature of dark energy by performing a blind search for Ly-α emitting galaxies within a 200 deg2 field and a redshift bin of 1.8 < z < 3.7. This will be achieved by VIRUS, a wide field, low resolution, 145 IFU spectrograph. The data reduction pipeline will have to extract ~ 35.000 spectra per exposure (~5 million per night, i.e. 500 million in total), perform an astrometric, photometric, and wavelength calibration, and find and classify objects in the spectra fully automatically. We will describe our ideas how to achieve this goal.

  13. Reductions in aircraft particulate emissions due to the use of Fischer-Tropsch fuels

    NASA Astrophysics Data System (ADS)

    Beyersdorf, A. J.; Timko, M. T.; Ziemba, L. D.; Bulzan, D.; Corporan, E.; Herndon, S. C.; Howard, R.; Miake-Lye, R.; Thornhill, K. L.; Winstead, E.; Wey, C.; Yu, Z.; Anderson, B. E.

    2013-06-01

    The use of alternative fuels for aviation is likely to increase due to concerns over fuel security, price stability and the sustainability of fuel sources. Concurrent reductions in particulate emissions from these alternative fuels are expected because of changes in fuel composition including reduced sulfur and aromatic content. The NASA Alternative Aviation Fuel Experiment (AAFEX) was conducted in January-February 2009 to investigate the effects of synthetic fuels on gas-phase and particulate emissions. Standard petroleum JP-8 fuel, pure synthetic fuels produced from natural gas and coal feedstocks using the Fischer-Tropsch (FT) process, and 50% blends of both fuels were tested in the CFM-56 engines on a DC-8 aircraft. To examine plume chemistry and particle evolution with time, samples were drawn from inlet probes positioned 1, 30, and 145 m downstream of the aircraft engines. No significant alteration to engine performance was measured when burning the alternative fuels. However, leaks in the aircraft fuel system were detected when operated with the pure FT fuels as a result of the absence of aromatic compounds in the fuel. Dramatic reductions in soot emissions were measured for both the pure FT fuels (reductions of 84% averaged over all powers) and blended fuels (64%) relative to the JP-8 baseline with the largest reductions at idle conditions. The alternative fuels also produced smaller soot (e.g. at 85% power, volume mean diameters were reduced from 78 nm for JP-8 to 51 nm for the FT fuel), which may reduce their ability to act as cloud condensation nuclei (CCN). The reductions in particulate emissions are expected for all alternative fuels with similar reductions in fuel sulfur and aromatic content regardless of the feedstock. As the plume cools downwind of the engine, nucleation-mode aerosols form. For the pure FT fuels, reductions (94% averaged over all powers) in downwind particle number emissions were similar to those measured at the exhaust plane (84%). However, the blended fuels had less of a reduction (reductions of 30-44%) than initially measured (64%). The likely explanation is that the reduced soot emissions in the blended fuel exhaust plume results in promotion of new particle formation microphysics, rather than coating on pre-existing soot particles, which is dominant in the JP-8 exhaust plume. Downwind particle volume emissions were reduced for both the pure (79 and 86% reductions) and blended FT fuels (36 and 46%) due to the large reductions in soot emissions. In addition, the alternative fuels had reduced particulate sulfate production (near-zero for FT fuels) due to decreased fuel sulfur content. To study the formation of volatile aerosols (defined as any aerosol formed as the plume ages) in more detail, tests were performed at varying ambient temperatures (-4 to 20 °C). At idle, particle number and volume emissions were reduced linearly with increasing ambient temperature, with best fit slopes corresponding to -1.2 × 106 # (kg fuel)-1 °C-1 for particle number emissions and -9.7 mm3 (kg fuel)-1 °C-1 for particle volume emissions. The temperature dependence of aerosol formation can have large effects on local air quality surrounding airports in cold regions. Aircraft produced aerosols in these regions will be much larger than levels expected based solely on measurements made directly at the engine exit plane. The majority (90% at idle) of the volatile aerosol mass formed as nucleation-mode aerosols with a smaller fraction as a soot coating. Conversion efficiencies of up to 3.8% were measured for the partitioning of gas-phase precursors (unburned hydrocarbons and SO2) to form volatile aerosols. Highest conversion efficiencies were measured at 45% power.

  14. Impact of chevron spacing and asymmetric distribution on supersonic jet acoustics and flow

    NASA Astrophysics Data System (ADS)

    Heeb, N.; Gutmark, E.; Kailasanath, K.

    2016-05-01

    An experimental investigation into the effect of chevron spacing and distribution on supersonic jets was performed. Cross-stream and streamwise particle imaging velocimetry measurements were used to relate flow field modification to sound field changes measured by far-field microphones in the overexpanded, ideally expanded, and underexpanded regimes. Drastic modification of the jet cross-section was achieved by the investigated configurations, with both elliptic and triangular shapes attained downstream. Consequently, screech was nearly eliminated with reductions in the range of 10-25 dB depending on the operating condition. Analysis of the streamwise velocity indicated that both the mean shock spacing and strength were reduced resulting in an increase in the broadband shock associated noise spectral peak frequency and a reduction in the amplitude, respectively. Maximum broadband shock associated noise amplitude reductions were in the 5-7 dB range. Chevron proximity was found to be the primary driver of peak vorticity production, though persistence followed the opposite trend. The integrated streamwise vorticity modulus was found to be correlated with peak large scale turbulent mixing noise reduction, though optimal overall sound pressure level reductions did not necessarily follow due to the shock/fine scale mixing noise sources. Optimal large scale mixing noise reductions were in the 5-6 dB range.

  15. Teaching the Basics: Development and Validation of a Distal Radius Reduction and Casting Model.

    PubMed

    Seeley, Mark A; Fabricant, Peter D; Lawrence, J Todd R

    2017-09-01

    Approximately one-third of reduced pediatric distal radius fractures redisplace, resulting in further treatment. Two major modifiable risk factors for loss of reduction are reduction adequacy and cast quality. Closed reduction and immobilization of distal radius fractures is an Accreditation Council for Graduate Medical Education residency milestone. Teaching and assessing competency could be improved with a life-like simulation training tool. Our goal was to develop and validate a realistic distal radius fracture reduction and casting simulator as determined by (1) a questionnaire regarding the "realism" of the model and (2) the quantitative assessments of reduction time, residual angulation, and displacement. A distal radius fracture model was created with radiopaque bony segments and articulating elbows and shoulders. Simulated periosteum and internal deforming forces required proper reduction and casting techniques to achieve and maintain reduction. The forces required were estimated through an iterative process through feedback from experienced clinicians. Embedded monofilaments allowed for quantitative assessment of residual displacement and angulation through the use of fluoroscopy. Subjects were asked to perform closed reduction and apply a long arm fiberglass cast. Primary performance variables assessed included reduction time, residual angulation, and displacement. Secondary performance variables consisted of number of fluoroscopic images, casting time, and cast index (defined as the ratio of the internal width of the forearm cast in the sagittal plane to the internal width in the coronal plane at the fracture site). Subject grading was performed by two blinded reviewers. Interrater reliability was nearly perfect across all measurements (intraclass correlation coefficient range, 0.94-0.99), thus disagreements in measurements were handled by averaging the assessed values. After completion the participants answered a Likert-based questionnaire regarding the realism of simulation. Eighteen participants consented to participate in the study (eight attending pediatric orthopaedic surgeons, six junior residents, four senior residents). The performances of junior residents (Postgraduate Year [PGY] 1-2), senior residents (PGY 3-5), and attending surgeons were compared using one-way ANOVA with Tukey's-adjusted pairwise comparisons. The majority of participants (15 of 18) felt that the model looked, felt, and moved like a human forearm. All participants strongly agreed that the model taught the basic steps of fracture reduction and should be implemented in orthopaedic training. Attending surgeons reduced fractures in less time than junior residents (60 ± 27 seconds versus 460 ± 62 seconds; mean difference, 400 seconds; 95% CI, 335-465 seconds; p < 0.001). Residual angulation was greater for junior residents when compared with attending surgeons on AP (7° ± 5° versus 0.7° ± 0.9°; mean difference, 6.3°; 95% CI, 3°-11°; p = 0.003) and lateral (27° ± 7° versus 7° ± 5°; mean difference, 20°; 95% CI, 13°-27°; p = 0.001) radiographs. Similarly, residual displacement was greater for junior residents than either senior residents (mean difference, 16 mm; 95% CI, 2-34 mm; p = 0.05) or attending surgeons (mean difference, 15 mm; 95% CI, 3-27 mm; p = 0.02) on lateral images. There were no differences identified in secondary performance variables (number of fluoroscopic images, casting time, and cast index) between groups. This is the first distal radius fracture reduction model to incorporate an elbow and shoulder and allow quantitative assessment of the fracture reduction. This simulator may be useful in an orthopaedic resident training program to help them reach a defined minimum level of competency. This simulator also could easily be integrated in other accreditation and training programs, including emergency medicine. Level II, therapeutic study.

  16. Rapid rather than gradual weight reduction impairs hemorheological parameters of Taekwondo athletes through reduction in RBC-NOS activation.

    PubMed

    Yang, Woo Hwi; Heine, Oliver; Pauly, Sebastian; Kim, Pilsang; Bloch, Wilhelm; Mester, Joachim; Grau, Marijke

    2015-01-01

    Rapid weight reduction is part of the pre-competition routine and has been shown to negatively affect psychological and physiological performance of Taekwondo (TKD) athletes. This is caused by a reduction of the body water and an electrolyte imbalance. So far, it is unknown whether weight reduction also affects hemorheological properties and hemorheology-influencing nitric oxide (NO) signaling, important for oxygen supply to the muscles and organs. For this purpose, ten male TKD athletes reduced their body weight by 5% within four days (rapid weight reduction, RWR). After a recovery phase, athletes reduced body weight by 5% within four weeks (gradual weight reduction, GWR). Each intervention was preceded by two baseline measurements and followed by a simulated competition. Basal blood parameters (red blood cell (RBC) count, hemoglobin concentration, hematocrit, mean corpuscular volume, mean cellular hemoglobin and mean cellular hemoglobin concentration), RBC-NO synthase activation, RBC nitrite as marker for NO synthesis, RBC deformability and aggregation parameters were determined on a total of eight investigation days. Basal blood parameters were not affected by the two interventions. In contrast to GWR, RWR decreased activation of RBC-NO synthase, RBC nitrite, respective NO concentration and RBC deformability. Additionally, RWR increased RBC aggregation and disaggregation threshold. The results point out that a rapid weight reduction negatively affects hemorheological parameters and NO signaling in RBC which might limit performance capacity. Thus, GWR should be preferred to achieve the desired weight prior to a competition to avoid these negative effects.

  17. Diesel engine emissions reduction by multiple injections having increasing pressure

    DOEpatents

    Reitz, Rolf D.; Thiel, Matthew P.

    2003-01-01

    Multiple fuel charges are injected into a diesel engine combustion chamber during a combustion cycle, and each charge after the first has successively greater injection pressure (a higher injection rate) than the prior charge. This injection scheme results in reduced emissions, particularly particulate emissions, and can be implemented by modifying existing injection system hardware. Further enhancements in emissions reduction and engine performance can be obtained by using known measures in conjunction with the invention, such as Exhaust Gas Recirculation (EGR).

  18. Rotational and translational diffusions of fluorescent probes during gelation process

    NASA Astrophysics Data System (ADS)

    Hattori, Yusuke; Panizza, Pascal; Letamendia, Louis; Ushiki, Hideharu

    2006-04-01

    Gelation process has been investigated by using light scattering techniques in recent years. We measured both of rotational and translational motions of fluorescent probes during gelation process. The measurements were performed after the temperature quenched at 30 °C. As the results, rotational diffusion coefficient of fluorescein was decreased after 6.0 × 10 4 s and energy transfer rate was reduced after 2.0 × 10 4 s. We sorted the gelation process into the following three parts, (I) pre-gelation, (II) reduction of translational diffusion (aging), and (III) reduction of rotational diffusion with saturating translational diffusion (post-gelation). The time scale of the process was completely different from the results of other methods.

  19. A randomized, controlled clinical study to investigate the safety and efficacy of acoustic wave therapy in body contouring.

    PubMed

    Nassar, Amer H; Dorizas, Andrew S; Shafai, Aria; Sadick, Neil S

    2015-03-01

    There is an increased demand for the reduction of localized adipose tissue by noninvasive methods. The objective of this study was to determine the safety and efficacy of noninvasive lipolysis of excess adiposities overlying the lateral thigh region using acoustic wave therapy (AWT). This study incorporates 2 mechanical waves with varying properties in the same session: radial and planar AWT. The treatment was performed using AWT on the lateral thigh areas of 15 female patients. The study was performed using the planar and radial pulse handpieces, with 8 sessions performed within 4 weeks. Follow-up visits were performed 1, 4, and 12 weeks after the last treatment. Reduction in both thigh circumference and subcutaneous fat layer thickness, measured through ultrasound, was observed. This study demonstrates that AWT is safe and efficacious for the treatment of localized adiposities in the saddlebag area. However, the results obtained were not statistically significant. Larger studies will be needed to further access the effects of AWT on thigh circumference reduction. Furthermore, the authors also found an improvement in the appearance of both cellulite and skin firmness after the treatments.

  20. Performance Evaluation of the COBRA GEM for the Application of the TPC

    NASA Astrophysics Data System (ADS)

    Terasaki, Kohei; Hamagaki, Hideki; Gunji, Taku; Yamaguchi, Yorito

    2014-09-01

    Suppression of the back-drifting ions from avalanche region to drift space (IBF: Ion Backflow) is the key for a Time Projection Chamber (TPC) since IBF easily distorts the drift field. To suppress IBF, Gating Grid system is widely used for the TPC but this limits the data taking rate. Gas Electron Multiplier (GEM) has advantages in the reduction of IBF and high rate capability. By adopting GEM, it is possible to run a TPC continuously under high rate and high multiplicity conditions. Motivated by the study of IBF reduction for RICH with Thick COBRA, which has been developed by F. A. Amero et al., we developed COBRA GEMs for the application of a TPC. With a stack configuration, IBF reaches about 0.1 ~ 0.5%, which is ×5--10 better IBF than the standard GEMs. However, the measured energy resolution with COBRA is 20% (σ) and this is much worse than the resolution with standard GEMs. Measurement of long-time stability of gain indicates that gain of COBRA varies significantly due to charging up effect. Simulation studies based on Garfield++ are performed for understanding quantitatively the reasons of worse energy resolution and instability of gain. In this presentation, we will report the simulation studies together with the measured performance of the COBRA GEM.

  1. Treatment efficacy of anti-hypertensive drugs in monotherapy or combination

    PubMed Central

    Paz, Marco A.; de-La-Sierra, Alejandro; Sáez, Marc; Barceló, María Antonia; Rodríguez, Juan José; Castro, Sonia; Lagarón, Cristina; Garrido, Josep M; Vera, Pilar; Coll-de-Tuero, Gabriel

    2016-01-01

    Abstract Background: The relative efficacy of antihypertensive drugs/combinations is not well known. Identifying the most effective ones and the patients’ characteristics associated with best performance of the drugs will improve management of hypertensive patients. Objective: To assess the blood pressure (BP) reduction attributed to antihypertensive drugs and identify characteristics associated with BP decrease. Data sources: MEDLINE, Cochrane Central Register of Controlled Trials from inception through July 2012 and selected papers. Study eligibility criteria: Double-blind, randomized clinical trials whose main result was the reduction in BP by antihypertensive treatment, with study population ≥50 or ≥25 if the study was a crossover, follow-up of at least 8 weeks, and available required data. Study appraisal and synthesis methods: Study data were independently extracted by multiple observers and introduced in an electronic database. Inconsistencies were resolved by discussion and referral back to the original articles. Meta-analysis was performed according to PRISMA statement and using a Bayesian framework. Main Outcome(s) and Measure(s): Mean decrease in systolic (SBP) and diastolic blood pressure (DBP) achieved by each drug or combination. Results: Two hundred eight trials including 94,305 patients were identified. In monotherapy, most drugs achieved 10 to 15 mm Hg SBP and 8 to 10 mm Hg DBP decreases. Olmesartan/amlodipine, olmesartan/hydrochlorothiazide, felodipine/metoprolol, and valsartan/hydrochlorothiazide were the combinations leading to the greatest mean SBP reductions (>20 mm Hg). Female sex and body mass index >25 kg/m2 were associated with more pronounced SBP and DBP reductions, whereas Afro-American ethnicity was associated with BP reductions smaller than the median. Results were adjusted by study duration, cardiovascular disease, and diabetes mellitus. Still, the estimation was performed using the mean administered doses, which do not exactly match those of the available drug formats. Limitations: Data corresponded to those obtained in each of the included trials; the analysis of the combinations was limited to the most recent ones; estimations were performed using the mean administered doses. Conclusions and implications: Certain drug combinations achieve BP reductions ranging from 20 to 25/10 to 15 mm Hg. Sex, ethnicity, and obesity are associated with antihypertensive response. This information can contribute to better selection of the antihypertensive drug, depending on the magnitude of pretreatment BP elevation. Guidelines should be revised. PMID:27472680

  2. Effects of Specific Alcohol Control Policy Measures on Alcohol-Related Mortality in Russia from 1998 to 2013.

    PubMed

    Khaltourina, Daria; Korotayev, Andrey

    2015-09-01

    To elucidate the possible effects of alcohol control policy measures on alcohol-related mortality in Russia between 1998 and 2013. Trends in mortality, alcohol production and sales were analyzed in conjunction with alcohol control legislative measures. Correlation analysis of health and alcohol market indicators was performed. Ethyl alcohol production was the strongest correlate of alcohol-related mortality, which is probably due to the fact that ethyl alcohol is used for both recorded and unrecorded alcohol production. Measures producing greatest mortality reduction effect included provisions which reduced ethyl alcohol production (introduction of minimum authorized capital for ethyl alcohol and liquor producers in 2006 and the requirement for distillery dreg processing), as well as measures to tax and denaturize ethanol-containing liquids in 2006. Liquor tax decrease in real terms was associated with rising mortality in 1998-1999, while excise tax increase was associated with mortality reduction in 2004 and since 2012. Conventional alcohol control measures may also have played a moderately positive role. Countries with high alcohol-related mortality should aim for a reduction in spirits consumption as a major health policy. Alcohol market centralization and reduction of the number of producers can have immediate strong effects on mortality. These measures should be combined with an increase in alcohol taxes and prices, as well as other established alcohol policy measures. In 2015 in Russia, this is not being implemented. In Russia, legislation enforcement including excise tax collection remains the major challenge. Another challenge will be the integration into the Eurasian Economic Union. © The Author 2015. Medical Council on Alcohol and Oxford University Press. All rights reserved.

  3. Airflow reduction during cold weather operation of residential heat recovery ventilators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McGugan, C.A.; Edwards, P.F.; Riley, M.A.

    1987-06-01

    Laboratory measurements of the performance of residential heat recovery ventilators have been carried out for the R-2000 Energy Efficient Home Program. This work was based on a preliminary test procedure developed by the Canadian Standards Association, part of which calls for testing the HRV under cold weather conditions. An environmental chamber was used to simulate outdoor conditions. Initial tests were carried out with an outdoor temperature of -20/sup 0/C; subsequent tests were carried out at a temperature of -25/sup 0/C. During the tests, airflows, temperatures, and relative humidities of airstreams entering and leaving the HRV, along with electric power inputs,more » were monitored. Frost buildup in the heat exchangers and defrost mechanisms, such as fan shutoff or recirculation, led to reductions in airflows. The magnitude of the reductions is dependent on the design of the heat exchanger and the defrost mechanism used. This paper presents the results of tests performed on a number of HRVs commercially available in Canada at the time of the testing. The flow reductions for the various defrost mechanisms are discussed.« less

  4. Tuning spontaneous polarization to alter water oxidation/reduction activities of LiNbO3

    NASA Astrophysics Data System (ADS)

    Fu, Hongwei; Song, Yan; Wu, Yangqing; Huang, Huiting; Fan, Guozheng; Xu, Jun; Li, Zhaosheng; Zou, Zhigang

    2018-02-01

    Here, we investigated the effects of spontaneous polarization on photoreactivities by using a ferroelectric material n-type congruent LiNbO3 single crystal as a model. It was found that c+ LiNbO3 was superior to c- LiNbO3 in photocatalytic water reduction, while c- LiNbO3 exhibited better performances for photoelectrochemical water oxidation than c+ LiNbO3. Using Kelvin probe force microscopy and open circuit potential methods, we observed that c- LiNbO3 generated a higher photovoltage and had a slower charge-recombination rate than c+ LiNbO3. The results of electrochemical impedance spectroscopy measurements indicated that c- LiNbO3 may favor the hole transport from the bulk to the surface compared with c+ LiNbO3, leading to the anisotropic performances of c+ and c- LiNbO3 in water oxidation/reduction. Therefore, tuning the direction of the polarization may be a strategy to dramatically prompt the photoreactivities of water oxidation or reduction.

  5. Feasibility Study for a Practical High Rotor Tip Clearance Turbine.

    DTIC Science & Technology

    GAS TURBINE BLADES ), (* TURBINE BLADES , TOLERANCES(MECHANICS)), (* TURBOFAN ENGINES , GAS TURBINES , AXIAL FLOW TURBINES , AXIAL FLOW TURBINE ROTORS...AERODYNAMIC CONFIGURATIONS, LEAKAGE(FLUID), MEASUREMENT, TEST METHODS, PERFORMANCE( ENGINEERING ), MATHEMATICAL PREDICTION, REDUCTION, PRESSURE, PREDICTIONS, NOZZLE GAS FLOW, COMBUSTION CHAMBER GASES, GAS FLOW.

  6. Fingers' vibration transmission and grip strength preservation performance of vibration reducing gloves.

    PubMed

    Hamouda, K; Rakheja, S; Dewangan, K N; Marcotte, P

    2018-01-01

    The vibration isolation performances of vibration reducing (VR) gloves are invariably assessed in terms of power tools' handle vibration transmission to the palm of the hand using the method described in ISO 10819 (2013), while the nature of vibration transmitted to the fingers is ignored. Moreover, the VR gloves with relatively low stiffness viscoelastic materials affect the grip strength in an adverse manner. This study is aimed at performance assessments of 12 different VR gloves on the basis of handle vibration transmission to the palm and the fingers of the gloved hand, together with reduction in the grip strength. The gloves included 3 different air bladder, 3 gel, 3 hybrid, and 2 gel-foam gloves in addition to a leather glove. Two Velcro finger adapters, each instrumented with a three-axis accelerometer, were used to measure vibration responses of the index and middle fingers near the mid-phalanges. Vibration transmitted to the palm was measured using the standardized palm adapter. The vibration transmissibility responses of the VR gloves were measured in the laboratory using the instrumented cylindrical handle, also described in the standard, mounted on a vibration exciter. A total of 12 healthy male subjects participated in the study. The instrumented handle was also used to measure grip strength of the subjects with and without the VR gloves. The results of the study showed that the VR gloves, with only a few exceptions, attenuate handle vibration transmitted to the fingers only in the 10-200 Hz and amplify middle finger vibration at frequencies exceeding 200 Hz. Many of the gloves, however, provided considerable reduction in vibration transmitted to the palm, especially at higher frequencies. These suggest that the characteristics of vibration transmitted to fingers differ considerably from those at the palm. Four of the test gloves satisfied the screening criteria of the ISO 10819 (2013) based on the palm vibration alone, even though these caused amplification of handle vibration at the fingers. The fingers' vibration transmission performance of gloves were further evaluated using a proposed finger frequency-weighting W f apart from the standardized W h -weighting. It is shown that the W h weighting generally overestimates the VR glove effectiveness in limiting the fingers vibration in the high (H: 200-1250 Hz) frequency range. Both the weightings, however, revealed comparable performance of gloves in the mid (M: 25-200 Hz) frequency range. The VR gloves, with the exception of the leather glove, showed considerable reductions in the grip strength (27-41%), while the grip strength reduction was not correlated with the glove material thickness. It is suggested that effectiveness of VR gloves should be assessed considering the vibration transmission to both the palm and fingers of the hand together with the hand grip strength reduction. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Comparing 2 methods of assessing 30-day readmissions: what is the impact on hospital profiling in the veterans health administration?

    PubMed

    Mull, Hillary J; Chen, Qi; O'Brien, William J; Shwartz, Michael; Borzecki, Ann M; Hanchate, Amresh; Rosen, Amy K

    2013-07-01

    The Centers for Medicare and Medicaid Services' (CMS) all-cause readmission measure and the 3M Health Information System Division Potentially Preventable Readmissions (PPR) measure are both used for public reporting. These 2 methods have not been directly compared in terms of how they identify high-performing and low-performing hospitals. To examine how consistently the CMS and PPR methods identify performance outliers, and explore how the PPR preventability component impacts hospital readmission rates, public reporting on CMS' Hospital Compare website, and pay-for-performance under CMS' Hospital Readmission Reduction Program for 3 conditions (acute myocardial infarction, heart failure, and pneumonia). We applied the CMS all-cause model and the PPR software to VA administrative data to calculate 30-day observed FY08-10 VA hospital readmission rates and hospital profiles. We then tested the effect of preventability on hospital readmission rates and outlier identification for reporting and pay-for-performance by replacing the dependent variable in the CMS all-cause model (Yes/No readmission) with the dichotomous PPR outcome (Yes/No preventable readmission). The CMS and PPR methods had moderate correlations in readmission rates for each condition. After controlling for all methodological differences but preventability, correlations increased to >90%. The assessment of preventability yielded different outlier results for public reporting in 7% of hospitals; for 30% of hospitals there would be an impact on Hospital Readmission Reduction Program reimbursement rates. Despite uncertainty over which readmission measure is superior in evaluating hospital performance, we confirmed that there are differences in CMS-generated and PPR-generated hospital profiles for reporting and pay-for-performance, because of methodological differences and the PPR's preventability component.

  8. Effect of pregnancy and breast-feeding on vertical mammaplasty.

    PubMed

    Cruz-Korchin, Norma; Korchin, Leo

    2006-01-01

    A retrospective study was performed to evaluate the effect of pregnancy and breast-feeding on the breasts of women who had undergone vertical reduction mammaplasty. The study group consisted of 57 women who had pregnancies after their vertical reduction mammaplasty. Of this group, 24 breast-fed. The control group consisted of 103 women who had vertical mammaplasty but no subsequent pregnancies. An evaluation form was completed that included the age, body mass index, amount of tissue removed per breast, pregnancies after the mammaplasty, history of breast-feeding, and breast measurements. All patients had breast measurements routinely performed postoperatively at 2 weeks and again at 2 years. The following measurements were obtained: mid-clavicle to nipple, and inframammary fold to inferior areola. No significant difference was found between the control and the study group regarding age (27 +/- 12 versus 29 +/- 10), body mass index (26 +/- 5 versus 27 +/- 4), and grams of tissue excised per breast (610 +/- 201 versus 598 +/- 279). The breast measurement from the mid-clavicle to nipple was not significantly altered by pregnancy with or without breast-feeding (p > 0.05). The distance between the inframammary fold and the inferior margin of the areola was significantly (p < 0.05) increased by pregnancy both with breast-feeding (4.1 +/- 2.3 cm) and without (3.5 +/- 2.6 cm) when compared with the control group (1.2 +/- 1.5 cm). The vertical mammaplasty has less tendency for pseudoptosis (bottoming out), but the alterations of breast volume brought about by pregnancy and breast-feeding may affect the final outcome of even this good reduction mammaplasty method.

  9. Conceptual design study of concentrator enhanced solar arrays for space applications. Performance evaluation of 5 KW and 20 KW systems in Si and GaAs at 1 AU employing a flat plate trough concentrator

    NASA Technical Reports Server (NTRS)

    1980-01-01

    A simple, efficient and very lightweight preliminary design for a 5 KW and 20 KW BOL output concentrated array evolved and is described by drawings. The relative effectiveness of this design, as compared to an unconcentrated planar array of equal power output, was measured by comparing power to mass performance of and the solar cell area required by each. Improvements in power to mass performance as high as 42% together with array area size reduction of 57% are possible in GaAs systems. By contrast, when the same concentrator design is applied to silicon systems, no improvement in power to mass can be obtained although array area reductions as high as 35% are obtainable.

  10. Reduction of Poisson noise in measured time-resolved data for time-domain diffuse optical tomography.

    PubMed

    Okawa, S; Endo, Y; Hoshi, Y; Yamada, Y

    2012-01-01

    A method to reduce noise for time-domain diffuse optical tomography (DOT) is proposed. Poisson noise which contaminates time-resolved photon counting data is reduced by use of maximum a posteriori estimation. The noise-free data are modeled as a Markov random process, and the measured time-resolved data are assumed as Poisson distributed random variables. The posterior probability of the occurrence of the noise-free data is formulated. By maximizing the probability, the noise-free data are estimated, and the Poisson noise is reduced as a result. The performances of the Poisson noise reduction are demonstrated in some experiments of the image reconstruction of time-domain DOT. In simulations, the proposed method reduces the relative error between the noise-free and noisy data to about one thirtieth, and the reconstructed DOT image was smoothed by the proposed noise reduction. The variance of the reconstructed absorption coefficients decreased by 22% in a phantom experiment. The quality of DOT, which can be applied to breast cancer screening etc., is improved by the proposed noise reduction.

  11. Hospital Characteristics Associated With Penalties in the Centers for Medicare & Medicaid Services Hospital-Acquired Condition Reduction Program.

    PubMed

    Rajaram, Ravi; Chung, Jeanette W; Kinnier, Christine V; Barnard, Cynthia; Mohanty, Sanjay; Pavey, Emily S; McHugh, Megan C; Bilimoria, Karl Y

    2015-07-28

    In fiscal year (FY) 2015, the Centers for Medicare & Medicaid Services (CMS) instituted the Hospital-Acquired Condition (HAC) Reduction Program, which reduces payments to the lowest-performing hospitals. However, it is uncertain whether this program accurately measures quality and fairly penalizes hospitals. To examine the characteristics of hospitals penalized by the HAC Reduction Program and to evaluate the association of a summary score of hospital characteristics related to quality with penalization in the HAC program. Data for hospitals participating in the FY2015 HAC Reduction Program were obtained from CMS' Hospital Compare and merged with the 2014 American Hospital Association Annual Survey and FY2015 Medicare Impact File. Logistic regression models were developed to examine the association between hospital characteristics and HAC program penalization. An 8-point hospital quality summary score was created using hospital characteristics related to volume, accreditations, and offering of advanced care services. The relationship between the hospital quality summary score and HAC program penalization was examined. Publicly reported process-of-care and outcome measures were examined from 4 clinical areas (surgery, acute myocardial infarction, heart failure, pneumonia), and their association with the hospital quality summary score was evaluated. Penalization in the HAC Reduction Program. Hospital characteristics associated with penalization. Of the 3284 hospitals participating in the HAC program, 721 (22.0%) were penalized. Hospitals were more likely to be penalized if they were accredited by the Joint Commission (24.0% accredited, 14.4% not accredited; odds ratio [OR], 1.33; 95% CI, 1.04-1.70); they were major teaching hospitals (42.3%; OR, 1.58; 95% CI, 1.09-2.29) or very major teaching hospitals (62.2%; OR, 2.61; 95% CI, 1.55-4.39; vs nonteaching hospitals, 17.0%); they cared for more complex patient populations based on case mix index (quartile 4 vs quartile 1: 32.8% vs 12.1%; OR, 1.98; 95% CI, 1.44-2.71); or they were safety-net hospitals vs non-safety-net hospitals (28.3% vs 19.9%; OR, 1.36; 95% CI, 1.11-1.68). Hospitals with higher hospital quality summary scores had significantly better performance on 9 of 10 publicly reported process and outcomes measures compared with hospitals that had lower quality scores (all P ≤ .01 for trend). However, hospitals with the highest quality score of 8 were penalized significantly more frequently than hospitals with the lowest quality score of 0 (67.3% [37/55] vs 12.6% [53/422]; P < .001 for trend). Among hospitals participating in the HAC Reduction Program, hospitals that were penalized more frequently had more quality accreditations, offered advanced services, were major teaching institutions, and had better performance on other process and outcome measures. These paradoxical findings suggest that the approach for assessing hospital penalties in the HAC Reduction Program merits reconsideration to ensure it is achieving the intended goals.

  12. Characterising microbial reduction of arsenate sorbed to ferrihydrite and its concurrence with iron reduction.

    PubMed

    Huang, Jen-How

    2018-03-01

    A series of model anoxic incubations were performed to understand the concurrence between arsenate and ferrihydrite reduction by Shewanella putrefaciens strain CN-32 at different concentrations of arsenate, ferrihydrite and lactate, and with given ΔG rxn for arsenate and ferrihydrite reduction in non-growth conditions. The reduction kinetics of arsenate sorbed to ferrihydrite is predominately controlled by the availability of dissolved arsenate, which is measured by the integral of dissolved arsenate concentrations against incubation time and shown to correlate with the first order rate constants. High lactate concentrations slightly slowed down the rate of arsenate reduction due to the competition with arsenate for microbial contact. Under all experimental conditions, simultaneous arsenate and ferrihydrite reduction occurred following addition of S. putrefaciens inoculums and suggested no apparent competition between these two enzymatic reductions. Ferrous ions released from iron reduction might retard microbial arsenate reduction at high arsenate and ferrihydrite concentrations due to formation of ferrous arsenate. At high arsenate to ferrihydrite ratios, reductive dissolution of ferrihydrite shifted arsenate from sorption to dissolution and hence accelerated arsenate reduction. The interaction between microbial arsenate and ferrihydrite reduction did not correlate with ΔG rxn , but instead was governed by other factors such as geochemical and microbial parameters. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. High performance miniature hygrometer and method thereof

    NASA Technical Reports Server (NTRS)

    VanZandt, Thomas R. (Inventor); Kaiser, William J. (Inventor); Kenny, Thomas W. (Inventor); Crisp, David (Inventor)

    1994-01-01

    An uncoated interdigitated transducer is cooled from a temperature above the dew point to a temperature below the dew point, while a parameter of a signal of the transducer is measured. The reduction in temperature causes a monotonic change in transducer signal because that signal is sensitive primarily to the water loading of the transducer surface as water forms on that surface due to the reduction in temperature. As the dew point is approached with temperature reduction, the slope of the curve of transducer signal with respect to temperature, remains relatively constant. However, as the dew point is reached the slope of that curve increases and because of changes in the structure of the water layer on the surface of the transducer, at the dew point the transducer responds with a clear shift in the rate at which the transducer signal changes. The temperature at which the second derivative of signal vs. temperature peaks can be readily used to identify with extreme accuracy, the precise dew point. The measurement technique employed by the present invention is relatively immune to surface contamination which remains significantly unchanged during the brief measurement period.

  14. Daily online testing in large classes: boosting college performance while reducing achievement gaps.

    PubMed

    Pennebaker, James W; Gosling, Samuel D; Ferrell, Jason D

    2013-01-01

    An in-class computer-based system, that included daily online testing, was introduced to two large university classes. We examined subsequent improvements in academic performance and reductions in the achievement gaps between lower- and upper-middle class students in academic performance. Students (N = 901) brought laptop computers to classes and took daily quizzes that provided immediate and personalized feedback. Student performance was compared with the same data for traditional classes taught previously by the same instructors (N = 935). Exam performance was approximately half a letter grade above previous semesters, based on comparisons of identical questions asked from earlier years. Students in the experimental classes performed better in other classes, both in the semester they took the course and in subsequent semester classes. The new system resulted in a 50% reduction in the achievement gap as measured by grades among students of different social classes. These findings suggest that frequent consequential quizzing should be used routinely in large lecture courses to improve performance in class and in other concurrent and subsequent courses.

  15. Dose reduction of up to 89% while maintaining image quality in cardiovascular CT achieved with prospective ECG gating

    NASA Astrophysics Data System (ADS)

    Londt, John H.; Shreter, Uri; Vass, Melissa; Hsieh, Jiang; Ge, Zhanyu; Adda, Olivier; Dowe, David A.; Sabllayrolles, Jean-Louis

    2007-03-01

    We present the results of dose and image quality performance evaluation of a novel, prospective ECG-gated Coronary CT Angiography acquisition mode (SnapShot Pulse, LightSpeed VCT-XT scanner, GE Healthcare, Waukesha, WI), and compare it to conventional retrospective ECG gated helical acquisition in clinical and phantom studies. Image quality phantoms were used to measure noise, slice sensitivity profile, in-plane resolution, low contrast detectability and dose, using the two acquisition modes. Clinical image quality and diagnostic confidence were evaluated in a study of 31 patients scanned with the two acquisition modes. Radiation dose reduction in clinical practice was evaluated by tracking 120 consecutive patients scanned with the prospectively gated scan mode. In the phantom measurements, the prospectively gated mode resulted in equivalent or better image quality measures at dose reductions of up to 89% compared to non-ECG modulated conventional helical scans. In the clinical study, image quality was rated excellent by expert radiologist reviewing the cases, with pathology being identical using the two acquisition modes. The average dose to patients in the clinical practice study was 5.6 mSv, representing 50% reduction compared to a similar patient population scanned with the conventional helical mode.

  16. Significant reduction in indoor radon in newly built houses.

    PubMed

    Finne, Ingvild E; Kolstad, Trine; Larsson, Maria; Olsen, Bård; Prendergast, Josephine; Rudjord, Anne Liv

    2018-02-15

    Results from two national surveys of radon in newly built homes in Norway, performed in 2008 and 2016, were used in this study to investigate the effect of the 2010 building regulations introducing limit values on radon and requirements for radon prevention measures upon construction of new buildings. In both surveys, homes were randomly selected from the National Building Registry. The overall result was a considerable reduction of radon concentrations after the implementation of new regulations, but the results varied between the different dwelling categories. A statistically significant reduction was found for detached houses where the average radon concentration was almost halved from 76 to 40 Bq/m 3 . The fraction of detached houses which had at least one frequently occupied room with a radon concentration above the Action Level (100 Bq/m 3 ) fell from 23.9% to 6.4%, while the fraction above the Upper Limit Value (200 Bq/m 3 ) was reduced from 7.6% to 2.5%. In 2008 the average radon concentration measured in terraced and semi-detached houses was 44 and in 2016 it was 29 Bq/m 3 , but the reduction was not statistically significant. For multifamily houses, it was not possible to draw a conclusion due to insufficient number of measurements. Copyright © 2018 Elsevier Ltd. All rights reserved.

  17. The carbon isotope biogeochemistry of (epsilon)CO2 production in a methanogenic marine sediment

    NASA Technical Reports Server (NTRS)

    Boehme, Susan E.

    1993-01-01

    To investigate the relationship between sigma(CO2) delta(C-13) values and rates of the dominant remineralization processes at the organic-rich field site of Cape Lookout Bight, NC, the isotopic composition of porewater sigma(CO2) was measured on a seasonal basis. The sigma(CO2) delta(C-13) values varies seasonally in response to changes in rates of sulfate reduction and methanogenesis, the dominant remineralization processes at this site. A tube incubation experiment was also performed to determine the isotopic signature of the sigma(CO2) produced by sulfate reduction and methanogenesis. The delta(C-13) of the sigma(CO2) produced in the sulfate reduction zone determined from the tube incubation was -14.3 plus or minus 1.9, a value enriched in C-13 relative to the labile organic fraction. The C-13-enrichment may be caused by low rates of methanogenesis occurring in the sulfate reduction zone. The delta(C-13) of the sigma(CO2) produced in the methanogenic zone was estimated to be +44 per mil, whereas the co-produced methane was -65 per mil. The fractionation factor for CO2 reduction was calculated to be 1.055, a value in agreement with previous estimates at this site. The measured concentration and delta(C-13) of the sigma(CO2) at Cape Lookout was closely reproduced by a diagenetic model using the measured rates of sulfate reduction and sigma(CO2) production, and the isotopic signature of the sigma(CO2) production in the two biogeochemical zones.

  18. Effects of the Irish smoking ban on respiratory health of bar workers and air quality in Dublin pubs.

    PubMed

    Goodman, Patrick; Agnew, Michelle; McCaffrey, Marie; Paul, Gillian; Clancy, Luke

    2007-04-15

    Environmental tobacco smoke (ETS) causes disease in nonsmokers. Workplace bans on smoking are interventions to reduce exposure to ETS to try to prevent harmful health effects. On March 29, 2004, the Irish government introduced the first national comprehensive legislation banning smoking in all workplaces, including bars and restaurants. This study examines the impact of this legislation on air quality in pubs and on respiratory health effects in bar workers in Dublin. Exposure study. Concentrations of particulate matter 2.5 microm or smaller (PM(2.5)) and particulate matter 10 microm or smaller (PM(10)) in 42 pubs were measured and compared before and after the ban. Benzene concentrations were also measured in 26 of the pubs. Health effects study. Eighty-one barmen volunteered to have full pulmonary function studies, exhaled breath carbon monoxide, and salivary cotinine levels performed before the ban and repeated 1 year after the ban. They also completed questionnaires on exposure to ETS and respiratory symptoms on both occasions. Exposure study. There was an 83% reduction in PM(2.5) and an 80.2% reduction in benzene concentration in the bars. Health effects study. There was a 79% reduction in exhaled breath carbon monoxide and an 81% reduction in salivary cotinine. There were statistically significant improvements in measured pulmonary function tests and significant reductions in self-reported symptoms and exposure levels in nonsmoking barmen volunteers after the ban. A total workplace smoking ban results in a significant reduction in air pollution in pubs and an improvement in respiratory health in barmen.

  19. Breast cancer screening effect across breast density strata: A case-control study.

    PubMed

    van der Waal, Daniëlle; Ripping, Theodora M; Verbeek, André L M; Broeders, Mireille J M

    2017-01-01

    Breast cancer screening is known to reduce breast cancer mortality. A high breast density may affect this reduction. We assessed the effect of screening on breast cancer mortality in women with dense and fatty breasts separately. Analyses were performed within the Nijmegen (Dutch) screening programme (1975-2008), which invites women (aged 50-74 years) biennially. Performance measures were determined. Furthermore, a case-control study was performed for women having dense and women having fatty breasts. Breast density was assessed visually with a dichotomized Wolfe scale. Breast density data were available for cases. The prevalence of dense breasts among controls was estimated with age-specific rates from the general population. Sensitivity analyses were performed on these estimates. Screening performance was better in the fatty than in the dense group (sensitivity 75.7% vs 57.8%). The mortality reduction appeared to be smaller for women with dense breasts, with an odds ratio (OR) of 0.87 (95% CI 0.52-1.45) in the dense and 0.59 (95% CI 0.44-0.79) in the fatty group. We can conclude that high density results in lower screening performance and appears to be associated with a smaller mortality reduction. Breast density is thus a likely candidate for risk-stratified screening. More research is needed on the association between density and screening harms. © 2016 UICC.

  20. Calibration of Reduced Dynamic Models of Power Systems using Phasor Measurement Unit (PMU) Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhou, Ning; Lu, Shuai; Singh, Ruchi

    2011-09-23

    Accuracy of a power system dynamic model is essential to the secure and efficient operation of the system. Lower confidence on model accuracy usually leads to conservative operation and lowers asset usage. To improve model accuracy, identification algorithms have been developed to calibrate parameters of individual components using measurement data from staged tests. To facilitate online dynamic studies for large power system interconnections, this paper proposes a model reduction and calibration approach using phasor measurement unit (PMU) data. First, a model reduction method is used to reduce the number of dynamic components. Then, a calibration algorithm is developed to estimatemore » parameters of the reduced model. This approach will help to maintain an accurate dynamic model suitable for online dynamic studies. The performance of the proposed method is verified through simulation studies.« less

  1. MONITOR THE PHOTOVOLTAIC (PV) SYSTEM ON THE NCC ROOFTOP

    EPA Science Inventory

    This study will investigate the pollution emission reduction and demand-side management potential of a
    100 kW PV system located on the roof of the National Computer Center (NCC). Standardized instrumentation to measure meteorological and PV system performance variables will b...

  2. The early effects of Medicare's mandatory hospital pay-for-performance program.

    PubMed

    Ryan, Andrew M; Burgess, James F; Pesko, Michael F; Borden, William B; Dimick, Justin B

    2015-02-01

    To evaluate the impact of hospital value-based purchasing (HVBP) on clinical quality and patient experience during its initial implementation period (July 2011-March 2012). Hospital-level clinical quality and patient experience data from Hospital Compare from up to 5 years before and three quarters after HVBP was initiated. Acute care hospitals were exposed to HVBP by mandate while critical access hospitals and hospitals located in Maryland were not exposed. We performed a difference-in-differences analysis, comparing performance on 12 incentivized clinical process and 8 incentivized patient experience measures between hospitals exposed to the program and a matched comparison group of nonexposed hospitals. We also evaluated whether hospitals that were ultimately exposed to HVBP may have anticipated the program by improving quality in advance of its introduction. Difference-in-differences estimates indicated that hospitals that were exposed to HVBP did not show greater improvement for either the clinical process or patient experience measures during the program's first implementation period. Estimates from our preferred specification showed that HVBP was associated with a 0.51 percentage point reduction in composite quality for the clinical process measures (p > .10, 95 percent CI: -1.37, 0.34) and a 0.30 percentage point reduction in composite quality for the patient experience measures (p > .10, 95 percent CI: -0.79, 0.19). We found some evidence that hospitals improved performance on clinical process measures prior to the start of HVBP, but no evidence of this phenomenon for the patient experience measures. The timing of the financial incentives in HVBP was not associated with improved quality of care. It is unclear whether improvement for the clinical process measures prior to the start of HVBP was driven by the expectation of the program or was the result of other factors. © Health Research and Educational Trust.

  3. SU-F-T-325: On the Use of Bolus in Dosimetry and Dose Reduction for Pacemaker and Defibrillator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, W; Kenneth, R; Higgins, S

    Purpose: Special attention is required in planning and administering radiation therapy to patients with cardiac implantable electronic devices (CIEDs), such as pacemaker and defibrillator. The range of dose to CIEDs that can induce malfunction is very large among CIEDs. Significant defects have been reported at dose as low as 0.15Gy. Failures causing discomfort have been reported at dose as low as 0.05Gy. Therefore, accurate estimation of dose to CIED and dose reduction are both important even if the dose is expected to be less than the often-used 2Gy limit. We investigate the use of bolus in in vivo dosimetry formore » CIEDs. Methods: In our clinic, high-energy beams (>10MV) are not used for patients with CIED due to neutron production. Solid water phantom measurements of out-of-field dose for a 6MV beam were performed using parallel plate chamber at different depth with and without 2cm bolus covering the chamber. In vivo dosimetry at skin surface above the pacemaker was performed with and without bolus for 3 patients with pacemaker <5cm from the field edge. Results: Chamber measured dose at depth ∼1 to 1.5cm below the skin surface, where the CIED is normally located, was reduced by ∼6% – 20% with bolus. The dose reduction became smaller at deeper depth. In vivo dosimetry at skin surface also yielded ∼20% – 60% lower dose when using bolus for the 3 patients. In general, TPS calculation underestimated the dose. The dose measured with bolus is closer to the dose at the depth of the pacemaker and less affected by contaminant electrons and linac head leakage. Conclusion: In vivo CIED dose measurements should be performed with 1 to 2cm bolus covering the dosimeter on the skin above the CIED for more accurate CIED dose estimation. The use of bolus also reduces the dose delivered to CIED.« less

  4. Diagnosing residual motion via the x-ray self emission from indirectly driven inertial confinement implosions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pak, A., E-mail: pak5@llnl.gov; Field, J. E.; Benedetti, L. R.

    2014-11-15

    In an indirectly driven implosion, non-radial translational motion of the compressed fusion capsule is a signature of residual kinetic energy not coupled into the compressional heating of the target. A reduction in compression reduces the peak pressure and nuclear performance of the implosion. Measuring and reducing the residual motion of the implosion is therefore necessary to improve performance and isolate other effects that degrade performance. Using the gated x-ray diagnostic, the x-ray Bremsstrahlung emission from the compressed capsule is spatially and temporally resolved at x-ray energies of >8.7 keV, allowing for measurements of the residual velocity. Here details of themore » x-ray velocity measurement and fitting routine will be discussed and measurements will be compared to the velocities inferred from the neutron time of flight detectors.« less

  5. Screening for Alzheimer's Disease: Cognitive Impairment in Self-Referred and Memory Clinic-Referred Patients.

    PubMed

    Kirsebom, Bjørn-Eivind; Espenes, Ragna; Waterloo, Knut; Hessen, Erik; Johnsen, Stein Harald; Bråthen, Geir; Aarsland, Dag; Fladby, Tormod

    2017-01-01

    Cognitive assessment is essential in tracking disease progression in AD. Presently, cohorts including preclinical at-risk participants are recruited by different means, which may bias cognitive and clinical features. We compared recruitment strategies to levels of cognitive functioning. We investigate recruitment source biases in self-referred and memory clinic-referred patient cohorts to reveal potential differences in cognitive performance and demographics among at-risk participants. We included 431 participants 40-80 years old. Participants were classified as controls (n = 132) or symptom group (n = 299). The symptom group comprised of subjective cognitive decline (SCD, n = 163) and mild cognitive impairment (MCI, n = 136). We compared cognitive performance and demographics in memory clinic-referrals (n = 86) to self-referred participants responding to advertisements and news bulletins (n = 179). Participants recruited by other means were excluded from analysis (n = 34). At symptom group level, we found significant reductions in cognitive performance in memory clinic-referrals compared to self-referrals. However, here reductions were only found within the MCI group. We found no differences in cognitive performance due to recruitment within the SCD group. The MCI group was significantly impaired compared to controls on all measures. Significant reductions in learning, and executive functions were also found for the SCD group. Regardless of recruitment method, both the SCD and MCI groups showed reductions in cognitive performance compared to controls. We found differences in cognitive impairment for memory clinic-referrals compared to self-referrals only within the MCI group, SCD-cases being equally affected irrespective of referral type.

  6. Spectral OCT with speckle contrast reduction for evaluation of the healing process after PRK and transepithelial PRK

    PubMed Central

    Kaluzny, Bartlomiej J.; Szkulmowski, Maciej; Bukowska, Danuta M.; Wojtkowski, Maciej

    2014-01-01

    We evaluate Spectral OCT (SOCT) with a speckle contrast reduction technique using resonant scanner for assessment of corneal surface changes after excimer laser photorefractive keratectomy (PRK) and we compare healing process between conventional PRK and transepithelial PRK. The measurements were performed before and after the surgery. Obtained results show that SOCT with a resonant scanner speckle contrast reduction is capable of providing information regarding the healing process after PRK. The main difference between the healing processes of PRK and TransPRK, assessed by SOCT, was the time to cover the stroma with epithelium, which was shorter in the TransPRK group. PMID:24761291

  7. A quantitative comparison of noise reduction across five commercial (hybrid and model-based) iterative reconstruction techniques: an anthropomorphic phantom study.

    PubMed

    Patino, Manuel; Fuentes, Jorge M; Hayano, Koichi; Kambadakone, Avinash R; Uyeda, Jennifer W; Sahani, Dushyant V

    2015-02-01

    OBJECTIVE. The objective of our study was to compare the performance of three hybrid iterative reconstruction techniques (IRTs) (ASiR, iDose4, SAFIRE) and their respective strengths for image noise reduction on low-dose CT examinations using filtered back projection (FBP) as the standard reference. Also, we compared the performance of these three hybrid IRTs with two model-based IRTs (Veo and IMR) for image noise reduction on low-dose examinations. MATERIALS AND METHODS. An anthropomorphic abdomen phantom was scanned at 100 and 120 kVp and different tube current-exposure time products (25-100 mAs) on three CT systems (for ASiR and Veo, Discovery CT750 HD; for iDose4 and IMR, Brilliance iCT; and for SAFIRE, Somatom Definition Flash). Images were reconstructed using FBP and using IRTs at various strengths. Nine noise measurements (mean ROI size, 423 mm(2)) on extracolonic fat for the different strengths of IRTs were recorded and compared with FBP using ANOVA. Radiation dose, which was measured as the volume CT dose index and dose-length product, was also compared. RESULTS. There were no significant differences in radiation dose and image noise among the scanners when FBP was used (p > 0.05). Gradual image noise reduction was observed with each increasing increment of hybrid IRT strength, with a maximum noise suppression of approximately 50% (48.2-53.9%). Similar noise reduction was achieved on the scanners by applying specific hybrid IRT strengths. Maximum noise reduction was higher on model-based IRTs (68.3-81.1%) than hybrid IRTs (48.2-53.9%) (p < 0.05). CONCLUSION. When constant scanning parameters are used, radiation dose and image noise on FBP are similar for CT scanners made by different manufacturers. Significant image noise reduction is achieved on low-dose CT examinations rendered with IRTs. The image noise on various scanners can be matched by applying specific hybrid IRT strengths. Model-based IRTs attain substantially higher noise reduction than hybrid IRTs irrespective of the radiation dose.

  8. Endovascular aneurysm repair delivery redesign leads to quality improvement and cost reduction.

    PubMed

    Warner, Courtney J; Horvath, Alexander J; Powell, Richard J; Columbo, Jesse A; Walsh, Teri R; Goodney, Philip P; Walsh, Daniel B; Stone, David H

    2015-08-01

    Endovascular aneurysm repair (EVAR) is now a mainstay of therapy for abdominal aortic aneurysm, although it remains associated with significant expense. We performed a comprehensive analysis of EVAR delivery at an academic medical center to identify targets for quality improvement and cost reduction in light of impending health care reform. All infrarenal EVARs performed from April 2011 to March 2012 were identified (N = 127). Procedures were included if they met standard commercial instructions for use guidelines, used a single manufacturer, and were billed to Medicare diagnosis-related group 238 (n = 49). By use of DMAIC (define, measure, analyze, improve, and control) quality improvement methodology (define, measure, analyze, improve, control), targets for EVAR quality improvement were identified and high-yield changes were implemented. Procedure technical costs were calculated before and after process redesign. Perioperative services and clinic visits were identified as targets for quality improvement efforts and cost reduction. Mean technical costs before the intervention were $31,672, with endograft implants accounting for 52%. Pricing redesign in collaboration with hospital purchasing reduced mean EVAR technical costs to $28,607, a 10% reduction in overall cost, with endograft implants now accounting for 46%. Perioperative implementation of instrument tray redesign reduced instrument use by 32% (184 vs 132 instruments), saving $50,000 annually. Unnecessary clinic visits were reduced by 39% (1.6 vs 1.1 clinic visits per patient) through implementation of a preclinic imaging protocol. There was no difference in mean length of stay after the intervention. Comprehensive EVAR delivery redesign leads to cost reduction and waste elimination while preserving quality. Future efforts to achieve more competitive and transparent device pricing will make EVAR more cost neutral and enhance its financial sustainability for health care systems. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  9. On the use of total aerobic spore bacteria to make treatment decisions due to Cryptosporidium risk at public water system wells.

    PubMed

    Berger, Philip; Messner, Michael J; Crosby, Jake; Vacs Renwick, Deborah; Heinrich, Austin

    2018-05-01

    Spore reduction can be used as a surrogate measure of Cryptosporidium natural filtration efficiency. Estimates of log10 (log) reduction were derived from spore measurements in paired surface and well water samples in Casper Wyoming and Kearney Nebraska. We found that these data were suitable for testing the hypothesis (H 0 ) that the average reduction at each site was 2 log or less, using a one-sided Student's t-test. After establishing data quality objectives for the test (expressed as tolerable Type I and Type II error rates), we evaluated the test's performance as a function of the (a) true log reduction, (b) number of paired samples assayed and (c) variance of observed log reductions. We found that 36 paired spore samples are sufficient to achieve the objectives over a wide range of variance, including the variances observed in the two data sets. We also explored the feasibility of using smaller numbers of paired spore samples to supplement bioparticle counts for screening purposes in alluvial aquifers, to differentiate wells with large volume surface water induced recharge from wells with negligible surface water induced recharge. With key assumptions, we propose a normal statistical test of the same hypothesis (H 0 ), but with different performance objectives. As few as six paired spore samples appear adequate as a screening metric to supplement bioparticle counts to differentiate wells in alluvial aquifers with large volume surface water induced recharge. For the case when all available information (including failure to reject H 0 based on the limited paired spore data) leads to the conclusion that wells have large surface water induced recharge, we recommend further evaluation using additional paired biweekly spore samples. Published by Elsevier GmbH.

  10. Reproducibility of three dimensional digital preoperative planning for the osteosynthesis of distal radius fractures.

    PubMed

    Yoshii, Yuichi; Kusakabe, Takuya; Akita, Kenichi; Tung, Wen Lin; Ishii, Tomoo

    2017-12-01

    A three-dimensional (3D) digital preoperative planning system for the osteosynthesis of distal radius fractures was developed for clinical practice. To assess the usefulness of the 3D planning for osteosynthesis, we evaluated the reproducibility of the reduction shapes and selected implants in the patients with distal radius fractures. Twenty wrists of 20 distal radius fracture patients who underwent osteosynthesis using volar locking plates were evaluated. The 3D preoperative planning was performed prior to each surgery. Four surgeons conducted the surgeries. The surgeons performed the reduction and the placement of the plate while comparing images between the preoperative plan and fluoroscopy. Preoperative planning and postoperative reductions were compared by measuring volar tilt and radial inclination of the 3D images. Intra-class correlation coefficients (ICCs) of the volar tilt and radial inclination were evaluated. For the implant choices, the ICCs for the screw lengths between the preoperative plan and the actual choices were evaluated. The ICCs were 0.644 (p < 0.01) and 0.625 (p < 0.01) for the volar tilt and radial inclination in the 3D measurements, respectively. The planned size of plate was used in all of the patients. The ICC for the screw length between preoperative planning and actual choice was 0.860 (p < 0.01). Good reproducibility for the reduction shape and excellent reproducibility for the implant choices were achieved using 3D preoperative planning for distal radius fracture. Three-dimensional digital planning was useful to visualize the reduction process and choose a proper implant for distal radius fractures. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2646-2651, 2017. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  11. Endovascular aneurysm repair delivery redesign leads to quality improvement and cost reduction

    PubMed Central

    Warner, Courtney J.; Horvath, Alexander J.; Powell, Richard J.; Columbo, Jesse A.; Walsh, Teri R.; Goodney, Philip P.; Walsh, Daniel B.; Stone, David H.

    2017-01-01

    Objective Endovascular aneurysm repair (EVAR) is now a mainstay of therapy for abdominal aortic aneurysm, although it remains associated with significant expense. We performed a comprehensive analysis of EVAR delivery at an academic medical center to identify targets for quality improvement and cost reduction in light of impending health care reform. Methods All infrarenal EVARs performed from April 2011 to March 2012 were identified (N = 127). Procedures were included if they met standard commercial instructions for use guidelines, used a single manufacturer, and were billed to Medicare diagnosis-related group 238 (n = 49). By use of DMAIC (define, measure, analyze, improve, and control) quality improvement methodology (define, measure, analyze, improve, control), targets for EVAR quality improvement were identified and high-yield changes were implemented. Procedure technical costs were calculated before and after process redesign. Results Perioperative services and clinic visits were identified as targets for quality improvement efforts and cost reduction. Mean technical costs before the intervention were $31,672, with endograft implants accounting for 52%. Pricing redesign in collaboration with hospital purchasing reduced mean EVAR technical costs to $28,607, a 10% reduction in overall cost, with endograft implants now accounting for 46%. Perioperative implementation of instrument tray redesign reduced instrument use by 32% (184 vs 132 instruments), saving $50,000 annually. Unnecessary clinic visits were reduced by 39% (1.6 vs 1.1 clinic visits per patient) through implementation of a preclinic imaging protocol. There was no difference in mean length of stay after the intervention. Conclusions Comprehensive EVAR delivery redesign leads to cost reduction and waste elimination while preserving quality. Future efforts to achieve more competitive and transparent device pricing will make EVAR more cost neutral and enhance its financial sustainability for health care systems. PMID:25935271

  12. Tribology study of reduced graphene oxide sheets on silicon substrate synthesized via covalent assembly.

    PubMed

    Ou, Junfei; Wang, Jinqing; Liu, Sheng; Mu, Bo; Ren, Junfang; Wang, Honggang; Yang, Shengrong

    2010-10-19

    Reduced graphene oxide (RGO) sheets were covalently assembled onto silicon wafers via a multistep route based on the chemical adsorption and thermal reduction of graphene oxide (GO). The formation and microstructure of RGO were analyzed by X-ray photoelectron spectroscopy (XPS), attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy, Raman spectroscopy, and water contact angle (WCA) measurements. Characterization by atomic force microscopy (AFM) was performed to evaluate the morphology and microtribological behaviors of the samples. Macrotribological performance was tested on a ball-on-plate tribometer. Results show that the assembled RGO possesses good friction reduction and antiwear ability, properties ascribed to its intrinsic structure, that is, the covalent bonding to the substrate and self-lubricating property of RGO.

  13. Effects of motion base and g-seat cueing of simulator pilot performance

    NASA Technical Reports Server (NTRS)

    Ashworth, B. R.; Mckissick, B. T.; Parrish, R. V.

    1984-01-01

    In order to measure and analyze the effects of a motion plus g-seat cueing system, a manned-flight-simulation experiment was conducted utilizing a pursuit tracking task and an F-16 simulation model in the NASA Langley visual/motion simulator. This experiment provided the information necessary to determine whether motion and g-seat cues have an additive effect on the performance of this task. With respect to the lateral tracking error and roll-control stick force, the answer is affirmative. It is shown that presenting the two cues simultaneously caused significant reductions in lateral tracking error and that using the g-seat and motion base separately provided essentially equal reductions in the pilot's lateral tracking error.

  14. Higher speed VCSELs by photon lifetime reduction

    NASA Astrophysics Data System (ADS)

    Westbergh, Petter; Gustavsson, Johan S.; Kögel, Benjamin; Haglund, Åsa; Larsson, Anders; Joel, Andrew

    2011-03-01

    The impedance characteristics and the effects of photon lifetime reduction on the performance of high-speed 850 nm VCSELs are investigated. Through S11 measurements and equivalent circuit modeling we show that the parasitic mesa capacitance can be significantly reduced by using multiple oxide layers. By performing a shallow surface etch (25 - 55 nm) on the fabricated VCSELs, we are able to reduce the photon lifetime by up to 80% and thereby significantly improve both static and dynamic properties of the VCSELs. By optimizing the photon lifetime we are able to enhance the 3dB modulation bandwidth of 7 μm oxide aperture VCSELs from 15 GHz to 23 GHz and finally demonstrate errorfree transmission at up to 40 Gbit/s.

  15. Pre-hospital electrocardiogram triage with telemedicine near halves time to treatment in STEMI: A meta-analysis and meta-regression analysis of non-randomized studies.

    PubMed

    Brunetti, Natale Daniele; De Gennaro, Luisa; Correale, Michele; Santoro, Francesco; Caldarola, Pasquale; Gaglione, Antonio; Di Biase, Matteo

    2017-04-01

    A shorter time to treatment has been shown to be associated with lower mortality rates in acute myocardial infarction (AMI). Several strategies have been adopted with the aim to reduce any delay in diagnosis of AMI: pre-hospital triage with telemedicine is one of such strategies. We therefore aimed to measure the real effect of pre-hospital triage with telemedicine in case of AMI in a meta-analysis study. We performed a meta-analysis of non-randomized studies with the aim to quantify the exact reduction of time to treatment achieved by pre-hospital triage with telemedicine. Data were pooled and compared by relative time reduction and 95% C.I.s. A meta-regression analysis was performed in order to find possible predictors of shorter time to treatment. Eleven studies were selected and finally evaluated in the study. The overall relative reduction of time to treatment with pre-hospital triage and telemedicine was -38/-40% (p<0.001). Absolute time reduction was significantly correlated to time to treatment in the control groups (p<0.001), while relative time reduction was independent. A non-significant trend toward shorter relative time reductions was observed over years. Pre-hospital triage with telemedicine is associated with a near halved time to treatment in AMI. The benefit is larger in terms of absolute time to treatment reduction in populations with larger delays to treatment. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Imaging Catalytic Activation of CO 2 on Cu 2O (110): A First-Principles Study

    DOE PAGES

    Li, Liang; Zhang, Rui; Vinson, John; ...

    2018-03-05

    Balancing global energy needs against increasing greenhouse gas emissions requires new methods for efficient CO 2 reduction. While photoreduction of CO 2 is a viable approach for fuel generation, the rational design of photocatalysts hinges on precise characterization of the surface catalytic reactions. Cu 2O is a promising next-generation photocatalyst, but the atomic-scale description of the interaction between CO 2 and the Cu 2O surface is largely unknown, and detailed experimental measurements are lacking. In this study, density-functional-theory (DFT) calculations have been performed to identify the Cu 2O (110) surface stoichiometry that favors CO 2 reduction. To facilitate interpretation ofmore » scanning tunneling microscopy (STM) and X-ray absorption near-edge structures (XANES) measurements, which are useful for characterizing catalytic reactions, we present simulations based on DFT-derived surface morphologies with various adsorbate types. STM and XANES simulations were performed using the Tersoff Hamann approximation and Bethe-Salpeter equation (BSE) approach, respectively. The results provide guidance for observation of CO 2 reduction reaction on, and rational surface engineering of, Cu 2O (110). In conclusion, they also demonstrate the effectiveness of computational image and spectroscopy modeling as a predictive tool for surface catalysis characterization.« less

  17. Life cycle environmental impacts of three products derived from wild-caught Antarctic krill (Euphausia superba).

    PubMed

    Parker, Robert W R; Tyedmers, Peter H

    2012-05-01

    Concern has been voiced in recent years regarding the environmental implications of the Antarctic krill fishery. Attention has focused primarily on ecological concerns, whereas other environmental aspects, including potentially globally problematic emissions and material and energy demands, have not been examined in detail. Here we apply life cycle assessment to measure the contributions of krill meal, oil, and omega-3 capsules to global warming, ozone depletion, acidification, eutrophication, energy use, and biotic resource use. Supply chains of one krill fishing and processing company, Aker BioMarine of Norway, were assessed. Impacts of krill products were found to be driven primarily by the combustion of fossil fuels onboard the fishing vessel and a transport/resupply vessel. Approximately 190 L of fuel are burned per tonne of raw krill landed, markedly higher than fuel inputs to reduction fisheries targeting other species. In contrast, the biotic resource use associated with extracting krill is relatively low compared to that of other reduction fisheries. Results of this study provide insight into the broader environmental implications of the krill fishery, comparisons between products derived from krill and other species targeted for reduction, opportunities for improving the fishery's performance, and a baseline against which to measure future performance. © 2012 American Chemical Society

  18. Investigation of oxygen reduction and methanol oxidation reaction activity of PtAu nano-alloy on surface modified porous hybrid nanocarbon supports

    NASA Astrophysics Data System (ADS)

    Parambath Vinayan, Bhaghavathi; Nagar, Rupali; Ramaprabhu, Sundara

    2016-09-01

    We investigate the electrocatalytic activity of PtAu alloy nanoparticles supported on various chemically modified carbon morphologies towards oxygen reduction reaction (ORR) and methanol oxidation reaction (MOR). The surface-modification of graphene nanosheets (f-G), multi-walled carbon nanotubes (f-MWNTs) and (graphene nanosheets-carbon nanotubes) hybrid support (f-G-MWNTs) were carried out by soft functionalization method using a cationic polyelectrolyte poly-(diallyldimethyl ammonium chloride). The Pt and PtAu alloy nanoparticles were dispersed over chemically modified carbon supports by sodium-borohydride assisted modified polyol reduction method. The electrochemical performance of all electrocatalysts were studied by half- and full-cell proton exchange membrane fuel cell (PEMFC) measurements and PtAu/f-G-MWNTs catalyst comparatively yielded the best catalytic performance. PEMFC full cell measurements of PtAu/f-G-MWNTs cathode electrocatalyst yield a maximum power density of 319 mW cm-2 at 60 °C without any back pressure,which is 2.1 times higher than that of cathode electrocatalyst Pt on graphene support. The high ORR and MOR activity of PtAu/f-G-MWNTs electrocatalyst is due to the alloying effect and inherent beneficial properties of porous hybrid nanocarbon support.

  19. Imaging Catalytic Activation of CO 2 on Cu 2O (110): A First-Principles Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Liang; Zhang, Rui; Vinson, John

    Balancing global energy needs against increasing greenhouse gas emissions requires new methods for efficient CO 2 reduction. While photoreduction of CO 2 is a viable approach for fuel generation, the rational design of photocatalysts hinges on precise characterization of the surface catalytic reactions. Cu 2O is a promising next-generation photocatalyst, but the atomic-scale description of the interaction between CO 2 and the Cu 2O surface is largely unknown, and detailed experimental measurements are lacking. In this study, density-functional-theory (DFT) calculations have been performed to identify the Cu 2O (110) surface stoichiometry that favors CO 2 reduction. To facilitate interpretation ofmore » scanning tunneling microscopy (STM) and X-ray absorption near-edge structures (XANES) measurements, which are useful for characterizing catalytic reactions, we present simulations based on DFT-derived surface morphologies with various adsorbate types. STM and XANES simulations were performed using the Tersoff Hamann approximation and Bethe-Salpeter equation (BSE) approach, respectively. The results provide guidance for observation of CO 2 reduction reaction on, and rational surface engineering of, Cu 2O (110). In conclusion, they also demonstrate the effectiveness of computational image and spectroscopy modeling as a predictive tool for surface catalysis characterization.« less

  20. Near-field acoustical holography of military jet aircraft noise

    NASA Astrophysics Data System (ADS)

    Wall, Alan T.; Gee, Kent L.; Neilsen, Tracianne; Krueger, David W.; Sommerfeldt, Scott D.; James, Michael M.

    2010-10-01

    Noise radiated from high-performance military jet aircraft poses a hearing-loss risk to personnel. Accurate characterization of jet noise can assist in noise prediction and noise reduction techniques. In this work, sound pressure measurements were made in the near field of an F-22 Raptor. With more than 6000 measurement points, this is the most extensive near-field measurement of a high-performance jet to date. A technique called near-field acoustical holography has been used to propagate the complex pressure from a two- dimensional plane to a three-dimensional region in the jet vicinity. Results will be shown and what they reveal about jet noise characteristics will be discussed.

  1. Performance Measurements and Mapping of a R-407C Vapor Injection Scroll Compressor

    NASA Astrophysics Data System (ADS)

    Lumpkin, Domenique; Spielbauer, Niklas; Groll, Eckhard

    2017-08-01

    Environmental conditions significantly define the performance of HVAC&R systems. Vapor compression systems in hot climates tend to operate at higher pressure ratios, leading to increased discharge temperatures. Higher discharge temperatures can lead to higher irreversibilities in the compression process, lower specific enthalpies differences across the evaporator, and possibly a reduction in the compressor life due to the breakdown of the oil used for lubrication. To counter these effects, the use of economized, vapor injection compressors is proposed for vapor compression systems in high temperature climates. Such compressors are commercially available for refrigeration applications, in particular, supermarket refrigeration systems. However, compressor maps for vapor injection compressors are limited and none exist for R-407C. Through calorimeter testing, a compressor map for a single-port vapor injection compressor using R-407C was developed. A standard correlation for mapping single-port vapor injection compressors is proposed and validated using the compressor test results. The system and compressor performance with and without vapor injection was considered. As expected, with vapor injection there was a reduction in compressor discharge temperatures and an increase in the system coefficient of performance. The proposed dimensionless correlation is more accurate than the AHRI polynomial for mapping the injection ratio, discharge temperature, and compressor heat loss. The predicted volumetric efficiency values from the dimensionless correlation is within 1% of the measured valued. Similarly, the predicted isentropic efficiency values are within 2% of the measured values.

  2. The Running Performance Profile of Elite Gaelic Football Match-Play.

    PubMed

    Malone, Shane; Solan, Barry; Collins, Kieran

    2017-01-01

    Malone, S, Solan, B, and Collins, K. The running performance profile of elite Gaelic football match-play. J Strength Cond Res 31(1): 30-36, 2017-The current study examined (a) the match running performance of Gaelic football and (b) the decrement in match running performance with respect to position. Global positioning satellite system technologies (4-Hz; VX Sport) were used with 3 elite intercounty teams across 3 full seasons with 250 full game data sets collected. Game movements were classified according to game actions and distance covered across speed zone thresholds (total distance [TD], high-speed running distance [HSRD; ≥17 km·h], sprint distance [SD; ≥22 km·h]; accelerations [n]; peak speed [km·h]). The influence of running performance in each quarter on the subsequent quarter was analyzed across all positional roles. The mean (±SD) TD and HSRD covered during the game were 8,889 ± 1,448 m and 1,596 ± 594 m, respectively. Results show a temporal profile for TD with reductions in the second (-4.1%), third (-5.9%) and fourth (-3.8%) quarters, respectively. There was a significant reduction in HSRD in the second (-8.8%), third (-15.9%), and fourth (-19.8%) quarters when compared to the first quarter (p < 0.001). Positional differences were observed for distance-based measures with the middle 3 positions (half-back, midfield, and half-forward) completing the highest running performances. These positions also showed increased decrements in TD and HSRD and SD across quarters. The current data indicate a reduction in exercise intensity over the duration of elite Gaelic football match-play. It is unclear if this reduction is because of fatigue, pacing, contextual factors, or nutritional strategies employed by players.

  3. Neutron Deep Penetration Calculations in Light Water with Monte Carlo TRIPOLI-4® Variance Reduction Techniques

    NASA Astrophysics Data System (ADS)

    Lee, Yi-Kang

    2017-09-01

    Nuclear decommissioning takes place in several stages due to the radioactivity in the reactor structure materials. A good estimation of the neutron activation products distributed in the reactor structure materials impacts obviously on the decommissioning planning and the low-level radioactive waste management. Continuous energy Monte-Carlo radiation transport code TRIPOLI-4 has been applied on radiation protection and shielding analyses. To enhance the TRIPOLI-4 application in nuclear decommissioning activities, both experimental and computational benchmarks are being performed. To calculate the neutron activation of the shielding and structure materials of nuclear facilities, the knowledge of 3D neutron flux map and energy spectra must be first investigated. To perform this type of neutron deep penetration calculations with the Monte Carlo transport code, variance reduction techniques are necessary in order to reduce the uncertainty of the neutron activation estimation. In this study, variance reduction options of the TRIPOLI-4 code were used on the NAIADE 1 light water shielding benchmark. This benchmark document is available from the OECD/NEA SINBAD shielding benchmark database. From this benchmark database, a simplified NAIADE 1 water shielding model was first proposed in this work in order to make the code validation easier. Determination of the fission neutron transport was performed in light water for penetration up to 50 cm for fast neutrons and up to about 180 cm for thermal neutrons. Measurement and calculation results were benchmarked. Variance reduction options and their performance were discussed and compared.

  4. Use of a physiological profile to document motor impairment in ageing and in clinical groups.

    PubMed

    Lord, S R; Delbaere, K; Gandevia, S C

    2016-08-15

    Ageing decreases exercise performance and is frequently accompanied by reductions in cognitive performance. Deterioration in the physiological capacity to stand, locomote and exercise can manifest itself as falling over and represents a significant deterioration in sensorimotor control. In the elderly, falling leads to serious morbidity and mortality with major societal costs. Measurement of a suite of physiological capacities that are required for successful motor performance (including vision, muscle strength, proprioception and balance) has been used to produce a physiological profile assessment (PPA) which has been tracked over the age spectrum and in different diseases (e.g. multiple sclerosis, Parkinson's disease). As well as measures of specific physiological capacities, the PPA generates an overall 'score' which quantitatively measures an individual's cumulative risk of falling. The present review collates data from the PPA (and the physiological capacities it measures) as well as its use in strategies to reduce falls in the elderly and those with different diseases. We emphasise that (i) motor impairment arises via reductions in a wide range of sensorimotor abilities; (ii) the PPA approach not only gives a snapshot of the physiological capacity of an individual, but it also gives insight into the deficits among groups of individuals with particular diseases; and (iii) deficits in seemingly restricted and disparate physiological domains (e.g. vision, strength, cognition) are funnelled into impairments in tasks requiring upright balance. Motor impairments become more prevalent with ageing but careful physiological measurement and appropriate interventions offer a way to maximise health across the lifespan. © 2015 The Authors. The Journal of Physiology © 2015 The Physiological Society.

  5. NASA Tech Briefs, February 2011

    NASA Technical Reports Server (NTRS)

    2011-01-01

    Topics covered include: Multi-Segment Radius Measurement Using an Absolute Distance Meter Through a Null Assembly; Fiber-Optic Magnetic-Field-Strength Measurement System for Lightning Detection; Photocatalytic Active Radiation Measurements and Use; Computer Generated Hologram System for Wavefront Measurement System Calibration; Non-Contact Thermal Properties Measurement with Low-Power Laser and IR Camera System; SpaceCube 2.0: An Advanced Hybrid Onboard Data Processor; CMOS Imager Has Better Cross-Talk and Full-Well Performance; High-Performance Wireless Telemetry; Telemetry-Based Ranging; JWST Wavefront Control Toolbox; Java Image I/O for VICAR, PDS, and ISIS; X-Band Acquisition Aid Software; Antimicrobial-Coated Granules for Disinfecting Water; Range 7 Scanner Integration with PaR Robot Scanning System; Methods of Antimicrobial Coating of Diverse Materials; High-Operating-Temperature Barrier Infrared Detector with Tailorable Cutoff Wavelength; A Model of Reduced Kinetics for Alkane Oxidation Using Constituents and Species for N-Heptane; Thermally Conductive Tape Based on Carbon Nanotube Arrays; Two Catalysts for Selective Oxidation of Contaminant Gases; Nanoscale Metal Oxide Semiconductors for Gas Sensing; Lightweight, Ultra-High-Temperature, CMC-Lined Carbon/Carbon Structures; Sample Acquisition and Handling System from a Remote Platform; Improved Rare-Earth Emitter Hollow Cathode; High-Temperature Smart Structures for Engine Noise Reduction and Performance Enhancement; Cryogenic Scan Mechanism for Fourier Transform Spectrometer; Piezoelectric Rotary Tube Motor; Thermoelectric Energy Conversion Technology for High-Altitude Airships; Combustor Computations for CO2-Neutral Aviation; Use of Dynamic Distortion to Predict and Alleviate Loss of Control; Cycle Time Reduction in Trapped Mercury Ion Atomic Frequency Standards; and A (201)Hg+ Comagnetometer for (199)Hg+ Trapped Ion Space Atomic Clocks.

  6. MC21 analysis of the MIT PWR benchmark: Hot zero power results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kelly Iii, D. J.; Aviles, B. N.; Herman, B. R.

    2013-07-01

    MC21 Monte Carlo results have been compared with hot zero power measurements from an operating pressurized water reactor (PWR), as specified in a new full core PWR performance benchmark from the MIT Computational Reactor Physics Group. Included in the comparisons are axially integrated full core detector measurements, axial detector profiles, control rod bank worths, and temperature coefficients. Power depressions from grid spacers are seen clearly in the MC21 results. Application of Coarse Mesh Finite Difference (CMFD) acceleration within MC21 has been accomplished, resulting in a significant reduction of inactive batches necessary to converge the fission source. CMFD acceleration has alsomore » been shown to work seamlessly with the Uniform Fission Site (UFS) variance reduction method. (authors)« less

  7. Effects of Training and Competition Load on Neuromuscular Recovery, Testosterone, Cortisol, and Match Performance During a Season of Professional Football

    PubMed Central

    Rowell, Amber E.; Aughey, Robert J.; Hopkins, William G.; Esmaeili, Alizera; Lazarus, Brendan H.; Cormack, Stuart J.

    2018-01-01

    Introduction: Training load and other measures potentially related to match performance are routinely monitored in team-sport athletes. The aim of this research was to examine the effect of training load on such measures and on match performance during a season of professional football. Materials and Methods: Training load was measured daily as session duration times perceived exertion in 23 A-League football players. Measures of exponentially weighted cumulative training load were calculated using decay factors representing time constants of 3–28 days. Players performed a countermovement jump for estimation of a measure of neuromuscular recovery (ratio of flight time to contraction time, FT:CT), and provided a saliva sample for measurement of testosterone and cortisol concentrations 1-day prior to each of 34 matches. Match performance was assessed via ratings provided by five coaching and fitness staff on a 5-point Likert scale. Effects of training load on FT:CT, hormone concentrations and match performance were modeled as quadratic predictors and expressed as changes in the outcome measure for a change in the predictor of one within-player standard deviation (1 SD) below and above the mean. Changes in each of five playing positions were assessed using standardization and magnitude-based inference. Results: The largest effects of training were generally observed in the 3- to 14-day windows. Center defenders showed a small reduction in coach rating when 14-day a smoothed load increased from −1 SD to the mean (-0.31, ±0.15; mean, ±90% confidence limits), whereas strikers and wide midfielders displayed a small increase in coach rating when load increased 1 SD above the mean. The effects of training load on FT:CT were mostly unclear or trivial, but effects of training load on hormones included a large increase in cortisol (102, ±58%) and moderate increase in testosterone (24, ±18%) in center defenders when 3-day smoothed training load increased 1 SD above the mean. A 1 SD increase in training load above the mean generally resulted in substantial reductions in testosterone:cortisol ratio. Conclusion: The effects of recent training on match performance and hormones in A-League football players highlight the importance of position-specific monitoring and training. PMID:29930514

  8. 40 CFR 65.158 - Performance test procedures for control devices.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... loading period during which regulated materials are loaded, and samples shall be collected using... applicable. The regulated material concentration and percent reduction may be measured as either total regulated material or as TOC (minus methane and ethane) according to the procedures specified. (1) Method 1...

  9. 40 CFR 65.158 - Performance test procedures for control devices.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... loading period during which regulated materials are loaded, and samples shall be collected using... applicable. The regulated material concentration and percent reduction may be measured as either total regulated material or as TOC (minus methane and ethane) according to the procedures specified. (1) Method 1...

  10. 40 CFR 65.158 - Performance test procedures for control devices.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... loading period during which regulated materials are loaded, and samples shall be collected using... applicable. The regulated material concentration and percent reduction may be measured as either total regulated material or as TOC (minus methane and ethane) according to the procedures specified. (1) Method 1...

  11. Respiratory Syncytial Virus (RSV): Neutralizing Antibody, a Correlate of Immune Protection.

    PubMed

    Piedra, Pedro A; Hause, Anne M; Aideyan, Letisha

    2016-01-01

    Assays that measure RSV-specific neutralizing antibody activity are very useful for evaluating vaccine candidates, performing seroprevalence studies, and detecting infection. Neutralizing antibody activity is normally measured by a plaque reduction neutralization assay or by a microneutralization assay with or without complement. These assays measure the functional capacity of serum (or other fluids) to neutralize virus infectivity in cells as compared to ELISA assays that only measure the binding capacity against an antigen. This chapter discusses important elements in standardization of the RSV-specific microneutralization assay for use in the laboratory.

  12. Improvement in anthropometric parameters after rational dietary intervention in women with Polycystic Ovary Syndrom as the best method to support treatment

    PubMed

    Szczuko, Małgorzata; Malarczyk, Inez; Zapałowska-Chwyć, Marta

    Polycystic ovary syndrome (PCOS) is a disorder often occurring in women at reproductive age. An important factor in PCOS pathogenesis is insulin resistance, which pronounces hyperandrogenism and leads to the development of various metabolic disorders The aim of this study is to determine the effect of reduction diet with low glycemic index (GI) on anthropometric parameters of women with PCOS and the assessment of the effectiveness of the diet on body mass and adipose tissue reduction The study was performed on 24 women with PCOS diagnosed with Rotterdam’s criteria. Anthropometric measurements and bioelectrical impedance were performed. All participants received 7-day diet and recommendations relating to the change in lifestyle. After three months of using the dietary recommendations the measurements were repeated Statistical significance was observed for body mass (↓on average by 5.93 kg±2.95), BMI (↓2.14 kg/m2±1.2), circumference of: waist (↓7.7 cm±5.9), hip (↓4.8 cm±5.4), arm (↓1.9 cm±3.7) and measurements of skin fold under the shoulder blade (↓4.8 mm±4,6), above iliac crest (↓6.76 mm±5.7) and above triceps brachii muscle (↓5.25 mm±7.4). Considering body composition measurements, statistically significant were differences in the measurements of BCMI (↑18.042±8.8), TBW expressed in percentage (↑2.729±2.75) and in litres (↑0.071±5.15), FM in percentage (↓3.291±5.6) and in kg (3.354 kg±4.9) Body mass reduction using a rational diet with low GI is an effective method to support of PCOS treatment. Using reduction diet for three months together with increased physical activity enables to reduce body weight by on average 5.93 kg, which increases the chances to treat infertility in women. This should be the suggested type of diet in PCOS treatment

  13. Reductions in aircraft particulate emissions due to the use of Fischer-Tropsch fuels

    NASA Astrophysics Data System (ADS)

    Beyersdorf, A. J.; Timko, M. T.; Ziemba, L. D.; Bulzan, D.; Corporan, E.; Herndon, S. C.; Howard, R.; Miake-Lye, R.; Thornhill, K. L.; Winstead, E.; Wey, C.; Yu, Z.; Anderson, B. E.

    2014-01-01

    The use of alternative fuels for aviation is likely to increase due to concerns over fuel security, price stability, and the sustainability of fuel sources. Concurrent reductions in particulate emissions from these alternative fuels are expected because of changes in fuel composition including reduced sulfur and aromatic content. The NASA Alternative Aviation Fuel Experiment (AAFEX) was conducted in January-February 2009 to investigate the effects of synthetic fuels on gas-phase and particulate emissions. Standard petroleum JP-8 fuel, pure synthetic fuels produced from natural gas and coal feedstocks using the Fischer-Tropsch (FT) process, and 50% blends of both fuels were tested in the CFM-56 engines on a DC-8 aircraft. To examine plume chemistry and particle evolution with time, samples were drawn from inlet probes positioned 1, 30, and 145 m downstream of the aircraft engines. No significant alteration to engine performance was measured when burning the alternative fuels. However, leaks in the aircraft fuel system were detected when operated with the pure FT fuels as a result of the absence of aromatic compounds in the fuel. Dramatic reductions in soot emissions were measured for both the pure FT fuels (reductions in mass of 86% averaged over all powers) and blended fuels (66%) relative to the JP-8 baseline with the largest reductions at idle conditions. At 7% power, this corresponds to a reduction from 7.6 mg kg-1 for JP-8 to 1.2 mg kg-1 for the natural gas FT fuel. At full power, soot emissions were reduced from 103 to 24 mg kg-1 (JP-8 and natural gas FT, respectively). The alternative fuels also produced smaller soot (e.g., at 85% power, volume mean diameters were reduced from 78 nm for JP-8 to 51 nm for the natural gas FT fuel), which may reduce their ability to act as cloud condensation nuclei (CCN). The reductions in particulate emissions are expected for all alternative fuels with similar reductions in fuel sulfur and aromatic content regardless of the feedstock. As the plume cools downwind of the engine, nucleation-mode aerosols form. For the pure FT fuels, reductions (94% averaged over all powers) in downwind particle number emissions were similar to those measured at the exhaust plane (84%). However, the blended fuels had less of a reduction (reductions of 30-44%) than initially measured (64%). The likely explanation is that the reduced soot emissions in the blended fuel exhaust plume results in promotion of new particle formation microphysics, rather than coating on pre-existing soot particles, which is dominant in the JP-8 exhaust plume. Downwind particle volume emissions were reduced for both the pure (79 and 86% reductions) and blended FT fuels (36 and 46%) due to the large reductions in soot emissions. In addition, the alternative fuels had reduced particulate sulfate production (near zero for FT fuels) due to decreased fuel sulfur content. To study the formation of volatile aerosols (defined as any aerosol formed as the plume ages) in more detail, tests were performed at varying ambient temperatures (-4 to 20 °C). At idle, particle number and volume emissions were reduced linearly with increasing ambient temperature, with best fit slopes corresponding to -8 × 1014 particles (kg fuel)-1 °C-1 for particle number emissions and -10 mm3 (kg fuel)-1 °C-1 for particle volume emissions. The temperature dependency of aerosol formation can have large effects on local air quality surrounding airports in cold regions. Aircraft-produced aerosols in these regions will be much larger than levels expected based solely on measurements made directly at the engine exit plane. The majority (90% at idle) of the volatile aerosol mass formed as nucleation-mode aerosols, with a smaller fraction as a soot coating. Conversion efficiencies of up to 2.8% were measured for the partitioning of gas-phase precursors (unburned hydrocarbons and SO2) to form volatile aerosols. Highest conversion efficiencies were measured at 45% power.

  14. Assessment of the dose reduction potential of a model-based iterative reconstruction algorithm using a task-based performance metrology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Samei, Ehsan, E-mail: samei@duke.edu; Richard, Samuel

    2015-01-15

    Purpose: Different computed tomography (CT) reconstruction techniques offer different image quality attributes of resolution and noise, challenging the ability to compare their dose reduction potential against each other. The purpose of this study was to evaluate and compare the task-based imaging performance of CT systems to enable the assessment of the dose performance of a model-based iterative reconstruction (MBIR) to that of an adaptive statistical iterative reconstruction (ASIR) and a filtered back projection (FBP) technique. Methods: The ACR CT phantom (model 464) was imaged across a wide range of mA setting on a 64-slice CT scanner (GE Discovery CT750 HD,more » Waukesha, WI). Based on previous work, the resolution was evaluated in terms of a task-based modulation transfer function (MTF) using a circular-edge technique and images from the contrast inserts located in the ACR phantom. Noise performance was assessed in terms of the noise-power spectrum (NPS) measured from the uniform section of the phantom. The task-based MTF and NPS were combined with a task function to yield a task-based estimate of imaging performance, the detectability index (d′). The detectability index was computed as a function of dose for two imaging tasks corresponding to the detection of a relatively small and a relatively large feature (1.5 and 25 mm, respectively). The performance of MBIR in terms of the d′ was compared with that of ASIR and FBP to assess its dose reduction potential. Results: Results indicated that MBIR exhibits a variability spatial resolution with respect to object contrast and noise while significantly reducing image noise. The NPS measurements for MBIR indicated a noise texture with a low-pass quality compared to the typical midpass noise found in FBP-based CT images. At comparable dose, the d′ for MBIR was higher than those of FBP and ASIR by at least 61% and 19% for the small feature and the large feature tasks, respectively. Compared to FBP and ASIR, MBIR indicated a 46%–84% dose reduction potential, depending on task, without compromising the modeled detection performance. Conclusions: The presented methodology based on ACR phantom measurements extends current possibilities for the assessment of CT image quality under the complex resolution and noise characteristics exhibited with statistical and iterative reconstruction algorithms. The findings further suggest that MBIR can potentially make better use of the projections data to reduce CT dose by approximately a factor of 2. Alternatively, if the dose held unchanged, it can improve image quality by different levels for different tasks.« less

  15. Development, implementation and evaluation of a dedicated metal artefact reduction method for interventional flat-detector CT.

    PubMed

    Prell, D; Kalender, W A; Kyriakou, Y

    2010-12-01

    The purpose of this study was to develop, implement and evaluate a dedicated metal artefact reduction (MAR) method for flat-detector CT (FDCT). The algorithm uses the multidimensional raw data space to calculate surrogate attenuation values for the original metal traces in the raw data domain. The metal traces are detected automatically by a three-dimensional, threshold-based segmentation algorithm in an initial reconstructed image volume, based on twofold histogram information for calculating appropriate metal thresholds. These thresholds are combined with constrained morphological operations in the projection domain. A subsequent reconstruction of the modified raw data yields an artefact-reduced image volume that is further processed by a combining procedure that reinserts the missing metal information. For image quality assessment, measurements on semi-anthropomorphic phantoms containing metallic inserts were evaluated in terms of CT value accuracy, image noise and spatial resolution before and after correction. Measurements of the same phantoms without prostheses were used as ground truth for comparison. Cadaver measurements were performed on complex and realistic cases and to determine the influences of our correction method on the tissue surrounding the prostheses. The results showed a significant reduction of metal-induced streak artefacts (CT value differences were reduced to below 22 HU and image noise reduction of up to 200%). The cadaver measurements showed excellent results for imaging areas close to the implant and exceptional artefact suppression in these areas. Furthermore, measurements in the knee and spine regions confirmed the superiority of our method to standard one-dimensional, linear interpolation.

  16. The blue skies in Beijing during APEC 2014: A quantitative assessment of emission control efficiency and meteorological influence

    NASA Astrophysics Data System (ADS)

    Liu, Hongli; He, Jing; Guo, Jianping; Miao, Yucong; Yin, Jinfang; Wang, Yuan; Xu, Hui; Liu, Huan; Yan, Yan; Li, Yuan; Zhai, Panmao

    2017-10-01

    Most previous studies attributed the alleviation of aerosol pollution to either emission control measures or favorable meteorological conditions. However, our understanding of their quantitative contribution is far from complete. In this study, based on model simulation using the CMA (China Meteorological Administration) Unified Atmospheric Chemistry Environment for aerosols (CUACE/Aero), in combination with simultaneous ground-based hourly PM2.5 observations, we aim to quantify the relative contributions of the emission control measures and meteorology to the blue-skies seen in Beijing during the Asia-Pacific Economic Cooperation (APEC) summit held in November of 2014. A series of model simulations have been performed over Beijing-Tianjin-Hebei (BTH) region by implementing nine different emission control schemes. To investigate the relative contributions of the emission control measures and meteorology, the study period has been divided into five episodes. Overall, the CUACE/Aero model can reasonably well reproduce the temporal and spatial evolution of PM2.5 during APEC 2014, although the model performance varies by different time periods and regions of interest. Model results show the emission control measures on average reduced the PM2.5 concentration by 41.3% in urban areas of Beijing and 39.7% in Huairou district, respectively, indicating emission control plays a significant role for the blue skies observed. Among all the emission control measures under investigation, local emission control in Beijing contributed the largest to the reduction of PM2.5 concentrations with a reduction of 35.5% in urban area of Beijing and 34.8% in Huairou, in contrast with the vehicle emission control in Hebei that contributed the least with a reduction of less than 1%. The emission control efficiency in five episodes has been assessed quantitatively, which falls in the range of 36.2%-41.2% in urban area of Beijing and 34.9%-40.7% in Huairou, indicative of no significant episode and geographic dependence in the emission control efficiency. The emission control measures and meteorology, however, alternated to dominate the absolute reduction of PM2.5 concentrations. When the weather conditions are unfavorable, emission control measures outperformed meteorology with a reduction of 55.3-59.4 μg/m3 in urban area of Beijing and 32.5-33 μg/m3 in Huairou. Conversely, when the northwesterly winds prevailed, meteorology tends to outweigh the role of emission control in accounting for the drop of PM2.5. The atmospheric dilution conditions are determined through the model calculation of the mass inflow of PM2.5 per unit volume near the surface. Our findings have significant implications for effective planning and implementation of emission control measures.

  17. Numerical and Experimental Evaluation on the Residual Stresses of Welded Joints

    NASA Astrophysics Data System (ADS)

    Huh, Sun Chul; Park, Wonjo; Yang, Haesug; Jung, Haeyoung; Kim, Chuyoung

    Wings for the defense industry such as fighters, missiles, and rockets should show no deformation or damage on the structure. The structures of existing wings had holes for weight reduction. The plates and frames were fixed with rivets or screws, which limited the weight reduction possible. In this study, an improvement was made in jointing methods through EB welding and laser welding. Welding strength was measured through tension testing. In addition, finite element analysis was performed for the welding process so as to deduce the optimum welding condition.

  18. Reduction in adipose tissue volume using a new high-power radiofrequency technology combined with infrared light and mechanical manipulation for body contouring.

    PubMed

    Adatto, Maurice A; Adatto-Neilson, Robyn M; Morren, Grietje

    2014-09-01

    A growing patient demand for a youthful skin appearance with a favorable body shape has led to the recent development of new noninvasive body contouring techniques. We have previously demonstrated that the combination of bipolar radiofrequency (RF) and optical energies with tissue manipulation is an efficient reshaping modality. Here, we investigated the efficacy and safety of a new high-power version of this combined technology, in terms of adipose tissue reduction and skin tightening. Thirty-five patients received one treatment per week over 6 weeks to their abdomen/flank, buttock, or thigh areas and were followed up to 3 months post completion of the treatment protocol. This new device has an increased power in the bipolar RF, as this parameter appears to be the most important energy modality for volume reduction. Patient circumferences were measured and comparisons of baseline and post treatment outcomes were made. Diagnostic ultrasound (US) measurements were performed in 12 patients to evaluate the reduction in adipose tissue volume, and a cutometer device was used to assess improvements in skin tightening. We observed a gradual decline in patient circumferences from baseline to post six treatments. The overall body shaping effect was accompanied with improvement in skin tightening and was clearly noticeable in the comparison of the before and after treatment clinical photographs. These findings correlated with measurements of adipose tissue volume and skin firmness/elasticity using diagnostic US and cutometer, respectively. The thickness of the fat layer showed on average a 29% reduction between baseline and the 1-month follow up. The average reduction in the circumference of the abdomen/flanks, buttocks, and thighs from baseline to the 3-month follow-up was 1.4, 0.5, and 1.2 cm, respectively, and 93% of study participants demonstrated a 1-60% change in fat layer thickness. Patients subjectively described comfort and satisfaction from treatment, and 97% of them were satisfied with the results at the follow-up visit. The application of high-power RF energy combined with infrared (IR), mechanical massage, and vacuum appears to be an effective modality for the reduction in circumferences of the abdomen/flank, buttock and thigh regions, and the improvement of skin appearance. The present study performed with a new device suggests that the underlying mechanism of action is reduction in the subcutaneous adipose tissue volume and intensification of dermal matrix density.

  19. An evaluation of noise reduction algorithms for particle-based fluid simulations in multi-scale applications

    NASA Astrophysics Data System (ADS)

    Zimoń, M. J.; Prosser, R.; Emerson, D. R.; Borg, M. K.; Bray, D. J.; Grinberg, L.; Reese, J. M.

    2016-11-01

    Filtering of particle-based simulation data can lead to reduced computational costs and enable more efficient information transfer in multi-scale modelling. This paper compares the effectiveness of various signal processing methods to reduce numerical noise and capture the structures of nano-flow systems. In addition, a novel combination of these algorithms is introduced, showing the potential of hybrid strategies to improve further the de-noising performance for time-dependent measurements. The methods were tested on velocity and density fields, obtained from simulations performed with molecular dynamics and dissipative particle dynamics. Comparisons between the algorithms are given in terms of performance, quality of the results and sensitivity to the choice of input parameters. The results provide useful insights on strategies for the analysis of particle-based data and the reduction of computational costs in obtaining ensemble solutions.

  20. Cathodal transcranial direct current stimulation in children with dystonia: a pilot open-label trial.

    PubMed

    Young, Scott J; Bertucco, Matteo; Sheehan-Stross, Rebecca; Sanger, Terence D

    2013-10-01

    Studies suggest that dystonia is associated with increased motor cortex excitability. Cathodal transcranial direct current stimulation can temporarily reduce motor cortex excitability. To test whether stimulation of the motor cortex can reduce dystonic symptoms in children, we measured tracking performance and muscle overflow using an electromyogram tracking task before and after stimulation. Of 10 participants, 3 showed a significant reduction in overflow, and a fourth showed a significant reduction in tracking error. Overflow decreased more when the hand contralateral to the cathode performed the task than when the hand ipsilateral to the cathode performed the task. Averaged over all participants, the results did not reach statistical significance. These results suggest that cathodal stimulation may allow a subset of children to control muscles or reduce involuntary overflow activity. Further testing is needed to confirm these results in a blinded trial and identify the subset of children who are likely to respond.

  1. Efficiency of an emissions payment system for nitrogen in sewage treatment plants - a case study.

    PubMed

    Malmaeus, J Mikael; Ek, Mats; Åmand, Linda; Roth, Susanna; Baresel, Christian; Olshammar, Mikael

    2015-05-01

    An emissions payment system for nitrogen in Swedish sewage treatment plants (STPs) was evaluated using a semi-empirical approach. The system was based on a tariff levied on each unit of nitrogen emitted by STPs, and profitable measures to reduce nitrogen emissions were identified for twenty municipal STPs. This was done through direct involvement with the plant personnel and the results were scaled up to cover all treatment plants larger than 2000 person equivalents in the Swedish tributary areas of the Kattegat and the Baltic Proper. The sum of costs and nitrogen reductions were compared with an assumed command-and-control regulation requiring all STPs to obtain 80% total nitrogen reduction in their effluents. Costs for the latter case were estimated using a database containing standard estimates for reduction costs by six specified measures. For both cases a total reduction target of 3000 tonnes of nitrogen was set. We did not find that the emissions payment system was more efficient in terms of total reduction costs, although some practical and administrative advantages could be identified. Our results emphasize the need to evaluate the performance of policy instruments on a case-by-case basis since the theoretical efficiency is not always reflected in practice. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Optimizing Performance Parameters of Chemically-Derived Graphene/p-Si Heterojunction Solar Cell.

    PubMed

    Batra, Kamal; Nayak, Sasmita; Behura, Sanjay K; Jani, Omkar

    2015-07-01

    Chemically-derived graphene have been synthesized by modified Hummers method and reduced using sodium borohydride. To explore the potential for photovoltaic applications, graphene/p-silicon (Si) heterojunction devices were fabricated using a simple and cost effective technique called spin coating. The SEM analysis shows the formation of graphene oxide (GO) flakes which become smooth after reduction. The absence of oxygen containing functional groups, as observed in FT-IR spectra, reveals the reduction of GO, i.e., reduced graphene oxide (rGO). It was further confirmed by Raman analysis, which shows slight reduction in G-band intensity with respect to D-band. Hall effect measurement confirmed n-type nature of rGO. Therefore, an effort has been made to simu- late rGO/p-Si heterojunction device by using the one-dimensional solar cell capacitance software, considering the experimentally derived parameters. The detail analysis of the effects of Si thickness, graphene thickness and temperature on the performance of the device has been presented.

  3. Lower-Order Compensation Chain Threshold-Reduction Technique for Multi-Stage Voltage Multipliers.

    PubMed

    Dell' Anna, Francesco; Dong, Tao; Li, Ping; Wen, Yumei; Azadmehr, Mehdi; Casu, Mario; Berg, Yngvar

    2018-04-17

    This paper presents a novel threshold-compensation technique for multi-stage voltage multipliers employed in low power applications such as passive and autonomous wireless sensing nodes (WSNs) powered by energy harvesters. The proposed threshold-reduction technique enables a topological design methodology which, through an optimum control of the trade-off among transistor conductivity and leakage losses, is aimed at maximizing the voltage conversion efficiency (VCE) for a given ac input signal and physical chip area occupation. The conducted simulations positively assert the validity of the proposed design methodology, emphasizing the exploitable design space yielded by the transistor connection scheme in the voltage multiplier chain. An experimental validation and comparison of threshold-compensation techniques was performed, adopting 2N5247 N-channel junction field effect transistors (JFETs) for the realization of the voltage multiplier prototypes. The attained measurements clearly support the effectiveness of the proposed threshold-reduction approach, which can significantly reduce the chip area occupation for a given target output performance and ac input signal.

  4. Screening of Potential Landing Gear Noise Control Devices at Virginia Tech For QTD II Flight Test

    NASA Technical Reports Server (NTRS)

    Ravetta, Patricio A.; Burdisso, Ricardo A.; Ng, Wing F.; Khorrami, Mehdi R.; Stoker, Robert W.

    2007-01-01

    In support of the QTD II (Quiet Technology Demonstrator) program, aeroacoustic measurements of a 26%-scale, Boeing 777 main landing gear model were conducted in the Virginia Tech Stability Tunnel. The objective of these measurements was to perform risk mitigation studies on noise control devices for a flight test performed at Glasgow, Montana in 2005. The noise control devices were designed to target the primary main gear noise sources as observed in several previous tests. To accomplish this task, devices to reduce noise were built using stereo lithography for landing gear components such as the brakes, the forward cable harness, the shock strut, the door/strut gap and the lower truck. The most promising device was down selected from test results. In subsequent stages, the initial design of the selected lower truck fairing was improved to account for all the implementation constraints encountered in the full-scale airplane. The redesigned truck fairing was then retested to assess the impact of the modifications on the noise reduction potential. From extensive acoustic measurements obtained using a 63-element microphone phased array, acoustic source maps and integrated spectra were generated in order to estimate the noise reduction achievable with each device.

  5. Use of the Frank-Starling mechanism during exercise is linked to exercise-induced changes in arterial load

    PubMed Central

    Chantler, Paul D.; Melenovsky, Vojtech; Schulman, Steven P.; Gerstenblith, Gary; Becker, Lewis C.; Ferrucci, Luigi; Fleg, Jerome L.; Najjar, Samer S.

    2012-01-01

    Effective arterial elastance(EA) is a measure of the net arterial load imposed on the heart that integrates the effects of heart rate(HR), peripheral vascular resistance(PVR), and total arterial compliance(TAC) and is a modulator of cardiac performance. To what extent the change in EA during exercise impacts on cardiac performance and aerobic capacity is unknown. We examined EA and its relationship with cardiovascular performance in 352 healthy subjects. Subjects underwent rest and exercise gated scans to measure cardiac volumes and to derive EA[end-systolic pressure/stroke volume index(SV)], PVR[MAP/(SV*HR)], and TAC(SV/pulse pressure). EA varied with exercise intensity: the ΔEA between rest and peak exercise along with its determinants, differed among individuals and ranged from −44% to +149%, and was independent of age and sex. Individuals were separated into 3 groups based on their ΔEAI. Individuals with the largest increase in ΔEA(group 3;ΔEA≥0.98 mmHg.m2/ml) had the smallest reduction in PVR, the greatest reduction in TAC and a similar increase in HR vs. group 1(ΔEA<0.22 mmHg.m2/ml). Furthermore, group 3 had a reduction in end-diastolic volume, and a blunted increase in SV(80%), and cardiac output(27%), during exercise vs. group 1. Despite limitations in the Frank-Starling mechanism and cardiac function, peak aerobic capacity did not differ by group because arterial-venous oxygen difference was greater in group 3 vs. 1. Thus the change in arterial load during exercise has important effects on the Frank-Starling mechanism and cardiac performance but not on exercise capacity. These findings provide interesting insights into the dynamic cardiovascular alterations during exercise. PMID:22003052

  6. Body shaping with acoustic wave therapy AWT(®)/EPAT(®): randomized, controlled study on 14 subjects.

    PubMed

    Adatto, Maurice A; Adatto-Neilson, Robin; Novak, Pavel; Krotz, Alexander; Haller, Gerd

    2011-12-01

    Reduction of localised adiposities by non invasive means is a very frequent request among the female and male population. The objective of this study is to demonstrate the efficacy and safety of AWT(®), combining two different mechanical waves, planar AWT and radial AWT during the same session, in volume reduction of saddle bags in women. Treatment was performed on the saddle bag areas of 14 female patients, with the CELLACTOR(®) SC1 (Storz Medical AG, Tägerwilen, Switzerland) using extracorporeal pulse activation technology, EPAT(®). This device includes two handpieces, the C-ACTOR(®) and the D-ACTOR(®). Within 4 weeks, eight AWT(®) treatment sessions have been performed with both applicators. Follow-up visits were performed 1, 4 and 12 weeks after the last treatment. Measurements with the ultrasound system clearly demonstrate a significant diminution in the subcutaneous fat layer thickness and a reduction of the averaged circumference of thighs. This study, although performed on a small number of patients, tends to show the safety and efficacy of AWT(®) in treating localized fat areas in a non-invasive way. There is also an additional benefit for patients in reducing the cellulite appearance and improving the skin firmness at the same time by using AWT(®).

  7. Does size matter - What other factors are limiting the rate performance of Na3V2(PO4)3 cathode in sodium-ion batteries

    NASA Astrophysics Data System (ADS)

    Jiang, Xi; Zhang, Tianran; Lee, Jim Yang

    2017-12-01

    Na3V2(PO4)3 (NVP) is an extensively researched cathode material for the sodium-ion batteries (NIBs). Size reduction and nanocarbon coating are often used to improve its rate performance. These are strategies that have been proven highly effective for LiFePO4 (LFP), a phosphate-based cathode material which is nowadays popular with the lithium-ion batteries. Nanocarbon coating is undoubtedly useful since NVP encounters similar external electron transport barriers as LFP. The effect of size reduction, however, remains debatable since in theory, the 3D NASICON framework of NVP is more efficient for solid state ionic diffusion than is LFP. We have undertaken the measurements of the electrochemical performance of NVP particles of different sizes, electrode compositions, active material loadings and processing conditions, for the purpose of identifying the most significant factors which determine the rate performance of NVP as a NIB cathode material.

  8. Forced Mixer Nozzle Optimization

    NASA Technical Reports Server (NTRS)

    Sheoran, Yogi; Hoover, Robert; Schuster, William; Anderson, Morris; Weir, Donald S.

    1999-01-01

    Computational fluid dynamic (CFD) and computational acoustic analyses (CAA) were performed for a TFE731-40 compound nozzle, a TFE731-60 mixer nozzle and an Energy Efficient Engine (E(sup 3)) mixer nozzle for comparison with available data. The CFD analyses were performed with a three dimensional, Navier-Stokes solution of the flowfield on an unstructured grid using the RAMPANT program. The CAA analyses were performed with the NASA Glenn MGB program using a structured grid. A successful aerodynamic solution for the TFE731-40 compound nozzle operating statically was obtained, simulating an engine operating on a test stand. Analysis of the CFD results of the TFE731-40 with the MGB program produced predicted sound power levels that agree quite well with the measured data front full-scale static engine tests. Comparison of the predicted sound pressure with the data show good agreement near the jet axis, but the noise levels are overpredicted at angles closer to the inlet. The predicted sound power level for the TFE731-60 did not agree as well with measured static engine data as the TFE731-40. Although a reduction in the predicted noise level due to the mixed flow was observed, the reduction was not as significant as the measured data. The analysis of the V2 mixer from the E(sup 3) study showed that peak temperatures predicted in the mixer exit flowfield were within 5 percent of the values measured by the exit probes. The noise predictions of the V2 mixer nozzle tended to be 3-5 dB higher in peak noise level than the measurements. In addition, the maximum frequency of the noise was also overpredicted. An analysis of the 3 candidate mixer nozzle configurations demonstrated the feasibility of using centerbody lobes and porosity to improve mixing efficiency. A final configuration was designed with a predicted thermal mixing efficiency that was 5 percent higher than the 3 candidate mixers. The results of the MGB noise calculations show that the final design will exceed the design goal of a 3 dB reduction in noise as compared to the baseline TFE731-40.

  9. Ultra-small single-negative electric metamaterials for electromagnetic coupling reduction of microstrip antenna array.

    PubMed

    Xu, He-Xiu; Wang, Guang-Ming; Qi, Mei-Qing; Zeng, Hui-Yong

    2012-09-24

    We report initially the design, fabrication and measurement of using waveguided electric metamaterials (MTM) in the design of closely-spaced microtrip antenna arrays with mutual coupling reduction. The complementary spiral ring resonators (CSRs) which exhibit single negative resonant permittivity around 3.5GHz are used as the basic electric MTM element. For verification, two CSRs with two and three concentric rings are considered, respectively. By properly arranging these well engineered waveguided MTMs between two H-plane coupled patch antennas, both numerical and measured results indicate that more than 8.4 dB mutual coupling reduction is obtained. The mechanism has been studied from a physical insight. The electric MTM element is electrically small, enabling the resultant antenna array to exhibit a small separation (λo/8 at the operating wavelength) and thus a high directivity. The proposed strategy opens an avenue to new types of antenna with super performances and can be generalized for other electric resonators.

  10. Reliability of quadriceps surface electromyography measurements is improved by two vs. single site recordings.

    PubMed

    Balshaw, T G; Fry, A; Maden-Wilkinson, T M; Kong, P W; Folland, J P

    2017-06-01

    The reliability of surface electromyography (sEMG) is typically modest even with rigorous methods, and therefore further improvements in sEMG reliability are desirable. This study compared the between-session reliability (both within participant absolute reliability and between-participant relative reliability) of sEMG amplitude from single vs. average of two distinct recording sites, for individual muscle (IM) and whole quadriceps (WQ) measures during voluntary and evoked contractions. Healthy males (n = 20) performed unilateral isometric knee extension contractions: voluntary maximum and submaximum (60%), as well as evoked twitch contractions on two separate days. sEMG was recorded from two distinct sites on each superficial quadriceps muscle. Averaging two recording sites vs. using single site measures improved reliability for IM and WQ measurements during voluntary (16-26% reduction in within-participant coefficient of variation, CV W ) and evoked contractions (40-56% reduction in CV W ). For sEMG measurements from large muscles, averaging the recording of two distinct sites is recommended as it improves within-participant reliability. This improved sensitivity has application to clinical and research measurement of sEMG amplitude.

  11. Effect of aromatherapy massage on elderly patients under long-term hospitalization in Japan.

    PubMed

    Satou, Tadaaki; Chikama, Mizuki; Chikama, Yoshiko; Hachigo, Masato; Urayama, Haruna; Murakami, Shio; Hayashi, Shinichiro; Koikem, Kazuo

    2013-03-01

    To verify the effectiveness of aromatherapy massage on elderly patients under long-term hospitalization. Aromatherapy massage was performed twice a week for a total of eight times. Nursing home. Elderly women under long-term hospitalization. Questionnaire and measurement of stress marker levels (salivary amylase activity) before and after the first, fifth, and eighth aromatherapy massages. Questionnaire (Face scale, General Health Questionnaire-12 [GHQ-12]), measurement of salivary amylase activity. A decrease in stress after aromatherapy massage compared to before each massage was confirmed at all measurement times and with the stress marker. No marked reduction was observed in Face scale or saliva amylase activity as a whole over the long term, although decreasing tendencies were seen. Marked reductions in GHQ-12 were observed over the long term. Aroma massage appears likely to prove effective in reducing psychological stress among elderly patients under long-term hospitalization.

  12. Speckle reduction in optical coherence tomography by adaptive total variation method

    NASA Astrophysics Data System (ADS)

    Wu, Tong; Shi, Yaoyao; Liu, Youwen; He, Chongjun

    2015-12-01

    An adaptive total variation method based on the combination of speckle statistics and total variation restoration is proposed and developed for reducing speckle noise in optical coherence tomography (OCT) images. The statistical distribution of the speckle noise in OCT image is investigated and measured. With the measured parameters such as the mean value and variance of the speckle noise, the OCT image is restored by the adaptive total variation restoration method. The adaptive total variation restoration algorithm was applied to the OCT images of a volunteer's hand skin, which showed effective speckle noise reduction and image quality improvement. For image quality comparison, the commonly used median filtering method was also applied to the same images to reduce the speckle noise. The measured results demonstrate the superior performance of the adaptive total variation restoration method in terms of image signal-to-noise ratio, equivalent number of looks, contrast-to-noise ratio, and mean square error.

  13. Truck Noise IX : Noise Reduction Study of an In-Service Diesel-Powered Truck : Volume 1. Text.

    DOT National Transportation Integrated Search

    1977-02-01

    A series of tests to measure the noise contributions of subsystems were performed on a truck with a conventional short cab, equipped with a Cummins V-903 engine. The data acquired in these tests were used to select retrofittable components which woul...

  14. Truck Noise IX : Noise Reduction Study of an In-Service Diesel Powered Truck : Volume 2. Appendix.

    DOT National Transportation Integrated Search

    1977-02-01

    A series of tests to measure the noise contributions of subsystems were performed on a truck with a conventional short cab, equipped with a Cummins V-903 engine. The data acquired in these tests were used to select retrofittable components which woul...

  15. Vividness and Control: Factors in the Effectiveness of Performance Visualization?

    ERIC Educational Resources Information Center

    Ayres, Joe; Hopf, Tim; Edwards, Patricia A.

    1999-01-01

    Compares the effects of imagery control and vividness, separately and in combination, on self-report measures of public speaking apprehension (PSA), state communication apprehension (CA), negative thinking, and behavioral disruption. Links imagery control and vividness to reductions in PSA, state CA, negative thinking, and behavioral disruption.…

  16. Radiographic Measurement of Displacement in Acetabular Fractures: A Systematic Review of the Literature.

    PubMed

    Dodd, Andrew; Osterhoff, Georg; Guy, Pierre; Lefaivre, Kelly A

    2016-06-01

    To report methods of measurement of radiographic displacement and radiographic outcomes in acetabular fractures described in the literature. A systematic review of the English literature was performed using EMBASE and Medline in August 2014. Inclusion criteria were studies of operatively treated acetabular fractures in adults with acute (<6 weeks) open reduction and internal fixation that reported radiographic outcomes. Exclusion criteria included case series with <10 patients, fractures managed >6 weeks from injury, acute total hip arthroplasty, periprosthetic fractures, time frame of radiographic outcomes not stated, missing radiographic outcome data, and non-English language articles. Basic information collected included journal, author, year published, number of fractures, and fracture types. Specific data collected included radiographic outcome data, method of measuring radiographic displacement, and methods of interpreting or categorizing radiographic outcomes. The number of reproducible radiographic measurement techniques (2/64) and previously described radiographic interpretation methods (4) were recorded. One radiographic reduction grading criterion (Matta) was used nearly universally in articles that used previously described criteria. Overall, 70% of articles using this criteria documented anatomic reductions. The current standard of measuring radiographic displacement in publications dealing with acetabulum fractures almost universally lacks basic description, making further scientific rigor, such as testing reproducibility, impossible. Further work is necessary to standardize radiographic measurement techniques, test their reproducibility, and qualify their validity or determine which measurements are important to clinical outcomes. Diagnostic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  17. Effects of heavy episodic drinking on physical performance in club level rugby union players.

    PubMed

    Prentice, Christopher; Stannard, Stephen R; Barnes, Matthew J

    2015-05-01

    This study investigated the effects of acute alcohol consumption, in a natural setting, on exercise performance in the 2 days after the drinking episode. Additionally, alcohol related behaviours of this group of rugby players were identified. Prospective cohort study. Nineteen male club rugby players volunteered for this study. Measures of counter movement jump, maximal lower body strength, repeated sprint ability and hydration were made 2 days before and in the 2 days following heavy episodic alcohol consumption. Participants completed a questionnaire at each time point so that alcohol consumption and sleep hours from the previous 24 h period could be quantified. Additionally, participants completed the Alcohol Use Disorders Test (AUDIT) prior to completing baseline measures of performance. Reported alcohol consumption ranged from 6 to >20 standard drinks (mean category scale score=11-19 standard drinks). A significant decrease in sleep hours (p=0.01) was reported after the drinking episode with participants reporting 1-3 h for the night. A significant reduction (-1.8±1.5 cm) in counter movement jump (p<0.01) the morning after the drinking episode was observed; no other measures were altered at any time point compared to baseline (p>0.05). AUDIT scores for this group (18.2±4.3) indicate regular alcohol consumption at a hazardous level. Heavy episodic alcohol use, and associated reduced sleep hours, results in a reduction in lower body power output but not other measures of anaerobic performance the morning after a drinking session. Full recovery from this behaviour is achieved by 2 days post drinking episode. Copyright © 2014 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  18. Loudspeakers: Modeling and control

    NASA Astrophysics Data System (ADS)

    Al-Ali, Khalid Mohammad

    This thesis documented a comprehensive study of loudspeaker modeling and control. A lumped-parameter model for a voice-coil loudspeaker in a vented enclosure was presented that derived from a consideration of physical principles. In addition, a low-frequency (20 Hz to 100 Hz), feedback control method designed to improve the nonlinear performance of the loudspeaker and a suitable performance measure for use in design and evaluation were proposed. Data from experiments performed on a variety of actual loudspeakers confirmed the practicality of the theory developed in this work. The lumped-parameter loudspeaker model, although simple, captured much of the nonlinear behavior of the loudspeaker. In addition, the model formulation allowed a straightforward application of modern control system methods and lent itself well to modern parametric identification techniques. The nonlinear performance of the loudspeaker system was evaluated using a suitable distortion measure that was proposed and compared with other distortion measures currently used in practice. Furthermore, the linearizing effect of feedback using a linear controller (both static and dynamic) was studied on a class of nonlinear systems. The results illustrated that the distortion reduction was potentially significant and a useful upper bound on the closed-loop distortion was found based on the sensitivity function of the system's linearization. A feedback scheme based on robust control theory was chosen for application to the loudspeaker system. Using the pressure output of the loudspeaker system for feedback, the technique offered significant advantages over those previously attempted. Illustrative examples were presented that proved the applicability of the theory developed in this dissertation to a variety of loudspeaker systems. The examples included a vented loudspeaker model and actual loudspeakers enclosed in both vented and sealed configurations. In each example, predictable and measurable distortion reduction at the output of the closed-loop system was recorded.

  19. [Neuropsychological methods of examination of age-specific performance parameters (author's transl)].

    PubMed

    Quatember, R; Maly, J

    1980-11-15

    200 test persons were subjected to a double-blind experiment involving a medication of K. H. 3 (Schwarzhaupt). The measurement procedures involved 9 apparatus dealing with psychophysiological measurement level methods and led to the following outcomes: 1) Increase of the psychomotor tempo of the dominant hand after 5 month application of K. H. 3 (motor performance series). -2) Reduction of reaction errors determined by a vigilance measurement instrument after 5 month treatment with K. H. 3 (evidenced by an increase in monotony resistance and continous attention). -3) Improvement of multiple-choice reactions (simultaneous reaction capacity) to optic, acoustic and orientation-linked stimuli (fewer false and delayed reactions). -4) Increase of visual attentiveness and visual short time memory after 5 month medication of K. H. 3 measured by the Cognitron concentration measurement device). No statistically significant differences of the investigated performance parameters were found between K. H. 3 and placebo groups after 3 month application of K. H. 3. The result of the present study involving measurements at the psychophysiological measurement level are compared with data of a previous study.

  20. Tic-reducing effects of music in patients with Tourette's syndrome: Self-reported and objective analysis.

    PubMed

    Bodeck, Sabine; Lappe, Claudia; Evers, Stefan

    2015-05-15

    Self-reports by musicians affected with Tourette's syndrome and other sources of anecdotal evidence suggest that tics stop when subjects are involved in musical activity. For the first time, we studied this effect systematically using a questionnaire design to investigate the subjectively assessed impact of musical activity on tic frequency (study 1) and an experimental design to confirm these results (study 2). A questionnaire was sent to 29 patients assessing whether listening to music and musical performance would lead to a tic frequency reduction or increase. Then, a within-subject repeated measures design was conducted with eight patients. Five experimental conditions were tested: baseline, musical performance, short time period after musical performance, listening to music and music imagery. Tics were counted based on videotapes. Analysis of the self-reports (study 1) yielded in a significant tic reduction both by listening to music and musical performance. In study 2, musical performance, listening to music and mental imagery of musical performance reduced tic frequency significantly. We found the largest reduction in the condition of musical performance, when tics almost completely stopped. Furthermore, we could find a short-term tic decreasing effect after musical performance. Self-report assessment revealed that active and passive participation in musical activity can significantly reduce tic frequency. Experimental testing confirmed patients' perception. Active and passive participation in musical activity reduces tic frequency including a short-term lasting tic decreasing effect. Fine motor control, focused attention and goal directed behavior are believed to be relevant factors for this observation. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Promoting Health Equity And Eliminating Disparities Through Performance Measurement And Payment.

    PubMed

    Anderson, Andrew C; O'Rourke, Erin; Chin, Marshall H; Ponce, Ninez A; Bernheim, Susannah M; Burstin, Helen

    2018-03-01

    Current approaches to health care quality have failed to reduce health care disparities. Despite dramatic increases in the use of quality measurement and associated payment policies, there has been no notable implementation of measurement strategies to reduce health disparities. The National Quality Forum developed a road map to demonstrate how measurement and associated policies can contribute to eliminating disparities and promote health equity. Specifically, the road map presents a four-part strategy whose components are identifying and prioritizing areas to reduce health disparities, implementing evidence-based interventions to reduce disparities, investing in the development and use of health equity performance measures, and incentivizing the reduction of health disparities and achievement of health equity. To demonstrate how the road map can be applied, we present an example of how measurement and value-based payment can be used to reduce racial disparities in hypertension among African Americans.

  2. Effects of noise and working memory capacity on memory processing of speech for hearing-aid users.

    PubMed

    Ng, Elaine Hoi Ning; Rudner, Mary; Lunner, Thomas; Pedersen, Michael Syskind; Rönnberg, Jerker

    2013-07-01

    It has been shown that noise reduction algorithms can reduce the negative effects of noise on memory processing in persons with normal hearing. The objective of the present study was to investigate whether a similar effect can be obtained for persons with hearing impairment and whether such an effect is dependent on individual differences in working memory capacity. A sentence-final word identification and recall (SWIR) test was conducted in two noise backgrounds with and without noise reduction as well as in quiet. Working memory capacity was measured using a reading span (RS) test. Twenty-six experienced hearing-aid users with moderate to moderately severe sensorineural hearing loss. Noise impaired recall performance. Competing speech disrupted memory performance more than speech-shaped noise. For late list items the disruptive effect of the competing speech background was virtually cancelled out by noise reduction for persons with high working memory capacity. Noise reduction can reduce the adverse effect of noise on memory for speech for persons with good working memory capacity. We argue that the mechanism behind this is faster word identification that enhances encoding into working memory.

  3. Pumping Performance and Turbidity Generation of Model 600/100 PNEUMA Pump. Main Text and Appendixes A and B.

    DTIC Science & Technology

    1982-04-01

    E. Hite, Jr. Richard A. Shafer James D. Ethridge, Jr. 9 . PERFORMING ORGANIZATION NAME AND ADDRESS i0. PROGRAM ELEMENT. PROJECT. TASK AREA A WORK UNIT...Appendix C (bound separately) contains tables of measured dat a and cal-LnIuated parameters interpolated at 9 -sec intervals for each test run. Unc lassi...Test Program . . . . . . . . . . . . . . . . . . . . . . . . 9 PART III: TEST RESULTS....................... Data Reduction and Presentation

  4. Benefits Derived From Laser Ranging Measurements for Orbit Determination of the GPS Satellite Orbit

    NASA Technical Reports Server (NTRS)

    Welch, Bryan W.

    2007-01-01

    While navigation systems for the determination of the orbit of the Global Position System (GPS) have proven to be very effective, the current research is examining methods to lower the error in the GPS satellite ephemerides below their current level. Two GPS satellites that are currently in orbit carry retro-reflectors onboard. One notion to reduce the error in the satellite ephemerides is to utilize the retro-reflectors via laser ranging measurements taken from multiple Earth ground stations. Analysis has been performed to determine the level of reduction in the semi-major axis covariance of the GPS satellites, when laser ranging measurements are supplemented to the radiometric station keeping, which the satellites undergo. Six ground tracking systems are studied to estimate the performance of the satellite. The first system is the baseline current system approach which provides pseudo-range and integrated Doppler measurements from six ground stations. The remaining five ground tracking systems utilize all measurements from the current system and laser ranging measurements from the additional ground stations utilized within those systems. Station locations for the additional ground sites were taken from a listing of laser ranging ground stations from the International Laser Ranging Service. Results show reductions in state covariance estimates when utilizing laser ranging measurements to solve for the satellite s position component of the state vector. Results also show dependency on the number of ground stations providing laser ranging measurements, orientation of the satellite to the ground stations, and the initial covariance of the satellite's state vector.

  5. Coding metasurface for broadband microwave scattering reduction with optical transparency.

    PubMed

    Chen, Ke; Cui, Li; Feng, Yijun; Zhao, Junming; Jiang, Tian; Zhu, Bo

    2017-03-06

    Metasurfaces have promised great possibilities in full control of the electromagnetic wavefront by spatially manipulating the phase characteristics across the interface. Here, we report a scheme to realize broadband backward scattering reduction through diffusion-like microwave reflection by utilizing a flexible indium-tin-oxide (ITO)-based ultrathin coding metasurface (less than 0.1 wavelength thick) with high optical transparence. The diffusion-like scattering is caused by the destructive interference of the scattered far-field electromagnetic wave, which is further attributed to the randomly distributed reflection phases on the metasurface composed of pre-designed meta-atoms arranged with a computer-generated pseudorandom coding sequence. Both simulation and measurement on fabricated prototype sample have been carried out to validate its performance, demonstrating a polarization-independent broadband (nearly from 8 GHz to 15 GHz) 10 dB scattering reduction with good oblique performance. The excellent performances can also be preserved to conformal cases when the flexible metasurface is uniformly wrapped around a metallic cylinder. The proposed metasurface may create new opportunities to tailor the exotic microwave scattering features with simultaneously high transmittance in visible frequencies, which could provide crucial benefits in many practical uses, such as window and solar panel applications.

  6. Asymmetry costs: effects of wing damage on hovering flight performance in the hawkmoth Manduca sexta.

    PubMed

    Fernández, María José; Driver, Marion E; Hedrick, Tyson L

    2017-10-15

    Flight performance is fundamental to the fitness of flying organisms. Whilst airborne, flying organisms face unavoidable wing wear and wing area loss. Many studies have tried to quantify the consequences of wing area loss to flight performance with varied results, suggesting that not all types of damage are equal and different species may have different means to compensate for some forms of wing damage with little to no cost. Here, we investigated the cost of control during hovering flight with damaged wings, specifically wings with asymmetric and symmetric reductions in area, by measuring maximum load lifting capacity and the metabolic power of hovering flight in hawkmoths ( Manduca sexta ). We found that while asymmetric and symmetric reductions are both costly in terms of maximum load lifting and hovering efficiency, asymmetric reductions are approximately twice as costly in terms of wing area lost. The moths also did not modulate flapping frequency and amplitude as predicted by a hovering flight model, suggesting that the ability to do so, possibly tied to asynchronous versus synchronous flight muscles, underlies the varied responses found in different wing clipping experiments. © 2017. Published by The Company of Biologists Ltd.

  7. The effectiveness of environmental strategies on noise reduction in a pediatric intensive care unit: creation of single-patient bedrooms and reducing noise sources.

    PubMed

    Kol, Emine; Aydın, Perihan; Dursun, Oguz

    2015-07-01

    Noise is a substantial problem for both patients and healthcare workers in hospitals. This study aimed to determine the effectiveness of environmental strategies (creating single-patient rooms and reducing noise sources) in noise reduction in a pediatric intensive care unit. Noise measurement in the unit was conducted in two phases. In the first phase, measurements aimed at determining the unit's present level of noise were performed over 4 weeks in December 2013. During the month following the first measurement phase, the intensive care unit (ICU) was moved to a new location and noise-reducing strategies were implemented. The second phase, in May 2014, measured noise levels in the newly constructed environment. The noise levels before and after environmental changes were statistically significant at 72.6 dB-A and 56 dB-A, respectively (p < .05). Single-patient rooms and noise-reducing strategies can be effective in controlling environmental noise in the ICU. © 2015, Wiley Periodicals, Inc.

  8. Determination of the Airborne Sound Insulation of a Straw Bale Partition Wall

    NASA Astrophysics Data System (ADS)

    Teslík, Jiří; Fabian, Radek; Hrubá, Barbora

    2017-06-01

    This paper describes the results of a scientific project focused on determining of the Airborne Sound Insulation of a peripheral non-load bearing wall made of straw bales expressed by Weighted Sound Reduction Index. Weighted Sound Reduction Index was determined by measuring in the certified acoustic laboratory at the Faculty of Mechanical Engineering at Brno University of Technology. The measured structure of the straw wall was modified in combinations with various materials, so the results include a wide range of possible compositions of the wall. The key modification was application of plaster on both sides of the straw bale wall. This construction as is frequently done in actual straw houses. The additional measurements were performed on the straw wall with several variants of additional wall of slab materials. The airborne sound insulation value has been also measured in separate stages of the construction. Thus it is possible to compare and determinate the effect of the single layers on the airborne sound insulation.

  9. Speckle reduction in laser projection displays through angle and wavelength diversity.

    PubMed

    Tran, Trinh-Thi-Kim; Svensen, Øyvind; Chen, Xuyuan; Akram, Muhammad Nadeem

    2016-02-20

    Speckle is the main obstacle for the use of laser light sources in projection technology. This paper focuses on speckle suppression by the reduction of temporal coherence which is provided by the broadband laser light. The investigation of the effect of laser spectrum width and multiple lasers on speckle contrast is discussed. A broader spectrum width of the laser light is attained by the use of multiple semiconductor laser diodes of the broad area type. Measurements of speckle contrast with and without angle diversity are performed for two and four laser diodes. The measurement of speckle contrast for a single laser diode is also presented for comparison. The experimental results show that multiple laser diodes provide lower speckle contrast as compared to a single laser diode. In addition, it is also shown in this paper that the wavelength distribution of independent laser diodes has an effect on speckle contrast. Two different types of blue laser diodes, Nichia NUB802T and Nichia NUB801E, which have slightly different central wavelengths, were used for the measurements. Four laser diodes with a combination of two types of laser diodes offer better speckle contrast reduction than four laser diodes of the same type due to an effective broader spectrum. Additional speckle contrast reduction is achieved through the angle diversity by using a dynamic deformable mirror.

  10. Combined Heat & Power Using the Infinia Concentrated Solar CHP PowerDish System

    DTIC Science & Technology

    2013-08-01

    been due to a temperature induced reduction in magnetic field strength (inside the generator) that in turn can cause a generator over-stroke which can... Measurements and Sensors 34 Table 4: Results Summary Performance Objectives (same as Table 2) 38 Table 5: Building 9246 Energy Consumption vs...and Building Measurement Instrumentation P&ID 28 Figure 12: Building 9246 Radiant Heating and Hot Water Equipment 29 Figure 13: Coolant Flow

  11. Intraocular pressure and pulsatile ocular blood flow after retrobulbar and peribulbar anaesthesia

    PubMed Central

    Watkins, R.; Beigi, B.; Yates, M.; Chang, B.; Linardos, E.

    2001-01-01

    AIMS—This study investigated the effect of peribulbar and retrobulbar local anaesthesia on intraocular pressure (IOP) and pulsatile ocular blood flow (POBF), as such anaesthetic techniques may adversely affect these parameters.
METHODS—20 eyes of 20 patients who were to undergo phacoemulsification cataract surgery were prospectively randomised to receive peribulbar or retrobulbar anaesthesia. The OBF tonometer (OBF Labs, Wiltshire, UK) was used to simultaneously measure IOP and POBF before anaesthesia and 1 minute and 10 minutes after anaesthesia. Between group comparisons of age, baseline IOP, and baseline POBF were performed using the non-parametric Mann-Whitney test. Within group comparisons of IOP and POBF measured preanaesthesia and post-anaesthesia were performed using the non-parametric Wilcoxon signed ranks test for both groups.
RESULTS—There was no statistically significant IOP increase post-anaesthesia in either group. In the group receiving peribulbar anaesthesia, there was a significant reduction in POBF initially post-anaesthesia which recovered after 10 minutes. In the group receiving retrobulbar anaesthesia, there was a persistent statistically significant reduction in POBF.
CONCLUSIONS—Retrobulbar and peribulbar injections have little effect on IOP. Ocular compression is not needed for IOP reduction when using local anaesthesia for cataract surgery. Conversely, POBF falls, at least for a short time, when anaesthesia for ophthalmic surgery is administered via a retrobulbar route or a peribulbar route. This reduction may be mediated by pharmacologically altered orbital vascular tone. It may be safer to use other anaesthetic techniques in patients with ocular vascular compromise.

 PMID:11423451

  12. A study of the real-world noise attenuation of the current hearing protection devices in typical workplaces using Field Microphone in Real Ear method.

    PubMed

    Aliabadi, Mohsen; Biabani, Azam; Golmohammadi, Rostam; Farhadian, Maryam

    2018-05-28

    Actual noise reduction of the earmuffs is considered as one of the main challenges for the evaluation of the effectiveness of a hearing conservation program. The current study aimed to determine the real world noise attenuation of current hearing protection devices in typical workplaces using a field microphone in real ear (FMIRE) method. In this cross-sectional study, five common earmuffs were investigated among 50 workers in two industrial factories with different noise characteristics. Noise reduction data was measured with the use of earmuffs based on the ISO 11904 standard, field microphone in real ear method, using noise dosimeter (SVANTEK, model SV 102) equipped with a microphone SV 25 model. The actual insertion losses (IL) of the tested earmuffs in octave band were lower than the labeled insertion loss data (p <  0.05). The frequency nature of noise to which workers are exposed has noticeable effects on the actual noise reduction of earmuffs (p <  0.05). The results suggest that the proportion of time using earmuffs has a considerable impact on the effective noise reduction during the workday. Data about the ambient noise characteristics is a key criterion when evaluating the acoustic performance of hearing protectors in any workplaces. Comfort aspects should be considered as one of the most important criteria for long-term use and effective wearing of hearing protection devices. FMIRE could facilitate rapid and simple measurement of the actual performance of the current earmuffs employed by workers during different work activities.

  13. Ultrasonic Measurement of Erosion/corrosion Rates in Industrial Piping Systems

    NASA Astrophysics Data System (ADS)

    Sinclair, A. N.; Safavi, V.; Honarvar, F.

    2011-06-01

    Industrial piping systems that carry aggressive corrosion or erosion agents may suffer from a gradual wall thickness reduction that eventually threatens pipe integrity. Thinning rates could be estimated from the very small change in wall thickness values measured by conventional ultrasound over a time span of at least a few months. However, measurements performed over shorter time spans would yield no useful information—minor signal distortions originating from grain noise and ultrasonic equipment imperfections prevent a meaningful estimate of the minuscule reduction in echo travel time. Using a Model-Based Estimation (MBE) technique, a signal processing scheme has been developed that enables the echo signals from the pipe wall to be separated from the noise. This was implemented in a laboratory experimental program, featuring accelerated erosion/corrosion on the inner wall of a test pipe. The result was a reduction in the uncertainty in the wall thinning rate by a factor of four. This improvement enables a more rapid response by system operators to a change in plant conditions that could pose a pipe integrity problem. It also enables a rapid evaluation of the effectiveness of new corrosion inhibiting agents under plant operating conditions.

  14. Phase 2 program on ground test of refanned JT8D turbofan engines and nacelles for the 727 airplane. Volume 3: Ground tests

    NASA Technical Reports Server (NTRS)

    1975-01-01

    The NASA Refan Program included full-scale performance and noise ground tests of both a current production (JT8D-15) and a refanned (JT8D-115) engine. A description of the two ground tests including detailed propulsion, noise, and structural test results is presented. The primary objectives of the total test program were comparison of JT8D-15 and JT8D-115 overall propulsion system performance and noise characteristics and determination of incremental component noise levels. Other objectives of the test program included: (1) determination of acoustic treatment effectiveness; (2) measurement of internal sound pressure levels; (3) measurement of inlet and exhaust hardware performance; (4) determination of center-engine surge margin; and (5) evaluation of certain structural characteristics associated with the 727 refan center-engine inlet duct and JT8D refan engine exhaust system. The JT8D-15 and -115 tests were conducted during September 1974 and January to March 1975, respectively. Analyses of the test data indicated that the JT8D-115, as compared to the JT8D-15, demonstrates a 12.5 percent to 13.2 percent reduction in static specific fuel consumption, and a reduction of 6 to 7 PNdB in a weighted average value of static tone corrected perceived noise level. Separated into noise components, a significant reduction was shown for the inlet fan, aft fan, exhaust duct flow, turbine, and jet noises. However, core noise was increased. Photographs of test stands and test equipment are shown.

  15. Processing, structure, and characterizaton of nickel-alumina composites obtained by the partial reduction of zirconia-doped nickel-aluminum oxide and application to the tempering of ceramics

    NASA Astrophysics Data System (ADS)

    Barbieri, Thomas John

    1999-11-01

    Partial reduction of the spinel compound NiAl2O4 results in a two phase composite mixture of Ni + Al2O3. The reduction reaction has a volume decrease associated with it, which theoretically could generate large residual stresses, which have the potential to "temper" a ceramic, i.e. to place the surface of a ceramic component into a state of residual compression. As the first step towards tempering a ceramic, it is necessary to demonstrate that appreciable stresses can be generated by this volume change, since they may be relieved by either cracking or diffusional relaxation processes at the high temperature of the reduction reaction. It was necessary to determine the best processing methods to use for producing the tempered specimens. Results are presented from a systematic study on the effect of the variation of processing parameters on the reduction behavior of NiAl2O4 doped with ZrO2. Specimen characteristics of interest were time required for reduction, microstructural development, volume contraction achieved and porosity generated during reduction, and the ability to survive the reduction process without fracturing. These results were applied to the tempering process. A simple specimen geometry was used for tempering which involved an Al 2O3 cylinder bonded to an outer NiAl2O4 ring. Finite element calculations were performed to predict the residual stresses generated by the volume contraction of the ring and the coefficient of thermal expansion, (CTE) mismatch between the Al2O3 core and the reduced composite ring. Stress measurements performed on the Al2 O3 core of each specimen using the "d vs. Sin 2Psi" method of X-ray diffraction indicate that only the CTE-induced stresses remain in the specimens after completion of the tempering process. Microstructural analysis of the tempered specimens was performed to determine if residual stresses were developed during reduction, and what processes occurred to relieve these stresses. The results indicate that stresses are generated during the reduction process, but they are dissipated through catastrophic fracture, cation rearrangement in the lattice, and creep. Further evidence of the presence of residual stresses during reduction was found in a decrease in coarsening rate in tempered specimens.

  16. Metasurface base on uneven layered fractal elements for ultra-wideband RCS reduction

    NASA Astrophysics Data System (ADS)

    Su, Jianxun; Cui, Yueyang; Li, Zengrui; Yang, Yaoqing Lamar; Che, Yongxing; Yin, Hongcheng

    2018-03-01

    A novel metasurface based on uneven layered fractal elements is designed and fabricated for ultra-wideband radar cross section (RCS) reduction in this paper. The proposed metasurface consists of two fractal subwavelength elements with different layer thickness. The reflection phase difference of 180° (±37°) between two unit cells covers an ultra-wide frequency range. Ultra-wideband RCS reduction results from the phase cancellation between two local waves produced by these two unit cells. The diffuse scattering of electromagnetic (EM) waves is caused by the randomized phase distribution, leading to a low monostatic and bistatic RCS simultaneously. This metasurface can achieve -10dB RCS reduction in an ultra-wide frequency range from 6.6 to 23.9 GHz with a ratio bandwidth (fH/fL) of 3.62:1 under normal incidences for both x- and y-polarized waves. Both the simulation and the measurement results are consistent to verify this excellent RCS reduction performance of the proposed metasurface.

  17. Alzheimer's disease: a correlative study.

    PubMed Central

    Neary, D; Snowden, J S; Mann, D M; Bowen, D M; Sims, N R; Northen, B; Yates, P O; Davison, A N

    1986-01-01

    In a study of 17 patients with histologically proven Alzheimer's disease the relationship between psychological, pathological and chemical measures of disorder was examined. Severity of dementia, determined by mental test performance, correlated highly with pathological change in large cortical neurons (cell loss and reduction in nuclear and nucleolar volume and cytoplasmic RNA content), to a lesser extent with cortical senile plaque and neurofibrillary tangle frequency and reduction in acetylcholine (ACh) synthesis, and not with reduction in choline acetyltransferase (CAT) activity. A strongly significant relationship was demonstrated between cell loss and reductions in nuclear and nucleolar volume and cytoplasmic RNA content. Reduction in CAT activity and senile plaque frequency were significantly correlated, thereby linking changes in the sub-cortical projection system of the nucleus basalis with the cortical pathology. The pattern of correlations suggests that the dementia of Alzheimer's disease is largely a reflection of the state of large cortical neurons, and it is argued that abnormalities in the latter may not be directly related to primary loss of cholinergic neurons in the subcortex. PMID:2420941

  18. Reduction of User Interaction by Autonomy

    NASA Technical Reports Server (NTRS)

    Morfopoulos, Arin; McHenry, Michael; Matthies, Larry

    2006-01-01

    This paper describes experiments that quantify the improvement that autonomous behaviors enable in the amount of user interaction required to navigate a robot in urban environments. Many papers have discussed various ways to measure the absolute level of autonomy of a system; we measured the relative improvement of autonomous behaviors over teleoperation across multiple traverses of the same course. We performed four runs each on an 'easy' course and a 'hard' course, where half the runs were teleoperated and half used more autonomous behaviors. Statistics show 40-70% reductions in the amount of time the user interacts with the control station; however, with the behaviors tested, user attention remained on the control station even when he was not interacting. Reducing the need for attention will require better obstacle detection and avoidance and better absolute position estimation.

  19. Reduction of Cr(VI) to Cr(III) in Artificially-Contaminated Soil using Chemical Reagents

    NASA Astrophysics Data System (ADS)

    Kostarelos, Konstantinos; Rao, Ennio; Reale, Daniela

    2010-05-01

    The presence of hexavalent chromium (CrVI) in soil is an environmental concern due to its effect on human health. The concern arises from the leaching and the seepage of Cr(VI) from soil to groundwater. A remediation approach that has been studied in the literature is that of reducing the hexavalent chromium to its trivalent form using a chemical reagent, namely ferrous sulfate heptahydrate (FeSO4.7H20). In this study, we compared performance of ferrous sulfate heptahydrate to sodium thiosulfate (Na2S2O3), a less costly reductant. The means of measuring the performance of the reductants is the US EPA's Toxicity Characteristic Leaching Procedure (TCLP), which states that the total chromium release from the soil must be less than 5 ppm. Because this treatment approach is pH sensitive and thus, susceptible to acid rain effects, it was studied with the intention that it be coupled with a stabilization/fixation approach so as to provide a second level of treatment; i.e., it is not intended to be the stand-alone treatment approach. In this study, the reductants were initially used to treat a contaminated, artificial soil and allowed to cure for varying time periods to determine the minimum curing time. Contaminated artificial soil were then prepared using the same percentage of white sand, kaolinite clay and potassium chromate and varying amount of water as a function of the humidity of the specimens in order to illucidate the effect of moisture on the reductant performance. Finally, the reductant (either ferrous sulfate heptahydrate or sodium thiosulfate) was added in varying doses to determine the best ratio Cr/reagent dose. Chromium release from the soil was evaluated with a modified Toxicity Characteristic Leaching Procedure (TCLP) test after allowing the samples to cure. Results indicated that chromium(VI) released from the specimens was less than 5 ppm for the samples treated with either ferrous sulfate heptahydrate (99.9% of reduction) and sodium thiosulfate (98.7% of reduction) with ratio Cr/reagent equal to 18.7 in both cases. In addition, samples treated with ferrous sulfate also exhibited a binding effect. In summary, reduction to a lower valence state can be an effective treatment option when coupled with a stabilization/solidification treatment, so that any chromium subsequently leached from the treated soil into groundwater is the less toxic and less mobile trivalent form of chromium. An alternative to ferrous sulfate heptahydrate, the less-expensive sodium thiosulfate, performed well as a reductant and is suggested for further study.

  20. Applying EVM to Satellite on Ground and In-Orbit Testing - Better Data in Less Time

    NASA Technical Reports Server (NTRS)

    Peters, Robert; Lebbink, Elizabeth-Klein; Lee, Victor; Model, Josh; Wezalis, Robert; Taylor, John

    2008-01-01

    Using Error Vector Magnitude (EVM) in satellite integration and test allows rapid verification of the Bit Error Rate (BER) performance of a satellite link and is particularly well suited to measurement of low bit rate satellite links where it can result in a major reduction in test time (about 3 weeks per satellite for the Geosynchronous Operational Environmental Satellite [GOES] satellites during ground test) and can provide diagnostic information. Empirical techniques developed to predict BER performance from EVM measurements and lessons learned about applying these techniques during GOES N, O, and P integration test and post launch testing, are discussed.

  1. Effect of carbon monoxide exposure on human sleep and psychomotor performance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    O'Donnell, R.D.; Chikos, P.; Theodore, J.

    1971-01-01

    Four volunteers exposed for 9 hr (11 p.m. to 8 a.m.) to 75 or 150 ppM CO had COHb concentrations of 5.9 and 12.7%, respectively. Sleep habits and subsequent performance were measured. CO induced slight changes in sleeping habits including more deep sleep at expense of light sleep (especially at beginning of exposure) and a reduction in number of sleep stage changes. However, REM sleep was not affected. No effect of CO on complex cognitive or psychromotor activity measured by mental arithmetic, time estimation, tracking and monitoring under moderate or heavy stress, tone-time difference estimation, and critical flicker fusion tests.

  2. The effects of gas mixtures on ion engine erosion and performance

    NASA Technical Reports Server (NTRS)

    Garner, Charles E.; Brophy, John R.; Aston, Graeme

    1987-01-01

    Erosion measurements were performed on a modified J-series 30 cm ion engine operating on xenon propellant. Erosion data was obtained by measuring the trench depth etched into masked polished metal samples for test durations of up to 24 hours. The data indicates that erosion is greatest at the cathode side of the baffle, with tantalum being the material with the least erosion of all materials tested. There is a clear indication of a significant reduction in erosion of all materials tested when nitrogen is added to the propellant. The technique used in these experiments requires test samples which are extremely smooth and flat.

  3. Short and long term efficiencies of debris risk reduction measures: Application to a European LEO mission

    NASA Astrophysics Data System (ADS)

    Lang, T.; Kervarc, R.; Bertrand, S.; Carle, P.; Donath, T.; Destefanis, R.; Grassi, L.; Tiboldo, F.; Schäfer, F.; Kempf, S.; Gelhaus, J.

    2015-01-01

    Recent numerical studies indicate that the low Earth orbit (LEO) debris environment has reached a point such that even if no further space launches were conducted, the Earth satellite population would remain relatively constant for only the next 50 years or so. Beyond that, the debris population would begin to increase noticeably, due to the production of collisional debris (Liou and Johnson, 2008). Measures to be enforced play thus a major role to preserve an acceptable space mission risk and ensure sustainable space activities. The identification of such measures and the quantification of their efficiency over time for LEO missions is of prime concern in the decision-making process, as it has been investigated for the last few decades by the Inter-Agency Space Debris Coordination Committee (IADC). This paper addresses the final results of a generic methodology and the characteristics of a tool developed to assess the efficiency of the risk reduction measures identified for the Sentinel-1 (S1) mission. This work is performed as part of the 34-month P2-ROTECT project (Prediction, Protection & Reduction of OrbiTal Exposure to Collision Threats), funded by the European Union within the Seventh Framework Programme. Three ways of risk reduction have been investigated, both in short and long-term, namely: better satellite protection, better conjunction prediction, and cleaner environment. According to our assumptions, the S1 mission vulnerability evaluations in the long term (from 2093 to 2100) show that full compliance to the mitigation measures leads to a situation twice safer than that induced by an active debris removal of 5 objects per year in a MASTER2009 Business-As-Usual context. Because these measures have visible risk reduction effects in the long term, complementary measures with short response time are also studied. In the short term (from 2013 to 2020), a better prediction of the conjunctions is more efficient than protecting the satellite S1 itself. By combining a better prediction with an enhanced satellite protection the S1 is estimated to extend its extra mission lifetime by 4% with respect to its nominal lifetime (7.25 years).

  4. Disease and the extended phenotype: parasites control host performance and survival through induced changes in body plan.

    PubMed

    Goodman, Brett A; Johnson, Pieter T J

    2011-01-01

    By definition, parasites harm their hosts. However, some forms of parasite-induced alterations increase parasite transmission between hosts, such that manipulated hosts can be considered extensions of the parasite's phenotype. While well accepted in principle, surprisingly few studies have quantified how parasite manipulations alter host performance and survival under field and laboratory conditions. By interfering with limb development, the trematode Ribeiroia ondatrae causes particularly severe morphological alterations within amphibian hosts that provide an ideal system to evaluate parasite-induced changes in phenotype. Here, we coupled laboratory performance trials with a capture-mark-recapture study of 1388 Pacific chorus frogs (Pseudacris regilla) to quantify the effects of parasite-induced malformations on host locomotion, foraging, and survival. Malformations, which affected ∼ 50% of metamorphosing frogs in nature, caused dramatic reductions in all measures of organismal function. Malformed frogs exhibited significantly shorter jumping distances (41% reduction), slower swimming speeds (37% reduction), reduced endurance (66% reduction), and lower foraging success relative to infected hosts without malformations. Furthermore, while normal and malformed individuals had comparable survival within predator-free exclosures, deformed frogs in natural populations had 22% lower biweekly survival than normal frogs and rarely recruited to the adult population over a two-year period. Our results highlight the ability of parasites to deeply alter multiple dimensions of host phenotype with important consequences for performance and survival. These patterns were best explained by malformation status, rather than infection per se, helping to decouple the direct and indirect effects of parasitism on host fitness.

  5. Disease and the Extended Phenotype: Parasites Control Host Performance and Survival through Induced Changes in Body Plan

    PubMed Central

    Goodman, Brett A.; Johnson, Pieter T. J.

    2011-01-01

    Background By definition, parasites harm their hosts. However, some forms of parasite-induced alterations increase parasite transmission between hosts, such that manipulated hosts can be considered extensions of the parasite's phenotype. While well accepted in principle, surprisingly few studies have quantified how parasite manipulations alter host performance and survival under field and laboratory conditions. Methodology/Principal Findings By interfering with limb development, the trematode Ribeiroia ondatrae causes particularly severe morphological alterations within amphibian hosts that provide an ideal system to evaluate parasite-induced changes in phenotype. Here, we coupled laboratory performance trials with a capture-mark-recapture study of 1388 Pacific chorus frogs (Pseudacris regilla) to quantify the effects of parasite-induced malformations on host locomotion, foraging, and survival. Malformations, which affected ∼50% of metamorphosing frogs in nature, caused dramatic reductions in all measures of organismal function. Malformed frogs exhibited significantly shorter jumping distances (41% reduction), slower swimming speeds (37% reduction), reduced endurance (66% reduction), and lower foraging success relative to infected hosts without malformations. Furthermore, while normal and malformed individuals had comparable survival within predator-free exclosures, deformed frogs in natural populations had 22% lower biweekly survival than normal frogs and rarely recruited to the adult population over a two-year period. Conclusions/Significance Our results highlight the ability of parasites to deeply alter multiple dimensions of host phenotype with important consequences for performance and survival. These patterns were best explained by malformation status, rather than infection per se, helping to decouple the direct and indirect effects of parasitism on host fitness. PMID:21633498

  6. Getting it right the first time: predicted performance guarantees from the analysis of emergent behavior in autonomous and semi-autonomous systems

    NASA Astrophysics Data System (ADS)

    Arkin, Ronald C.; Lyons, Damian; Shu, Jiang; Nirmal, Prem; Zafar, Munzir

    2012-06-01

    A crucially important aspect for mission-critical robotic operations is ensuring as best as possible that an autonomous system be able to complete its task. In a project for the Defense Threat Reduction Agency (DTRA) we are developing methods to provide such guidance, specifically for counter-Weapons of Mass Destruction (C-WMD) missions. In this paper, we describe the scenarios under consideration, the performance measures and metrics being developed, and an outline of the mechanisms for providing performance guarantees.

  7. Structural Dynamics and Evolution of Bismuth Electrodes during Electrochemical Reduction of CO 2 in Imidazolium-Based Ionic Liquid Solutions

    DOE PAGES

    Medina-Ramos, Jonnathan; Lee, Sang Soo; Fister, Timothy T.; ...

    2017-09-12

    Real-time changes in the composition and structure of bismuth electrodes used for catalytic conversion of CO 2 into CO were examined via X-ray absorption spectroscopy (including XANES and EXAFS), electrochemical quartz crystal microbalance (EQCM) and in situ X-ray reflectivity (XR). Measurements were performed with bismuth electrodes immersed in acetonitrile (MeCN) solutions containing a 1-butyl-3-methylimidazolium ([BMIM] +) ionic liquid promoter or electrochemically inactive tetrabutylammonium supporting electrolytes (TBAPF 6 or TBAOTf). Altogether, these measurements show that bismuth electrodes are originally a mixture of bismuth oxides (including Bi 2O 3) and metallic bismuth (Bi 0), and that the reduction of oxidized bismuth speciesmore » to Bi 0 is fully achieved under potentials at which CO 2 activation takes place. Furthermore, EQCM measurements conducted during cyclic voltammetry revealed that a bismuth-coated quartz crystal exhibits significant shifts in resistance (ΔR) prior to the onset of CO 2 reduction near -1.75 V vs. Ag/AgCl and pronounced hysteresis in frequency (Δf) and ΔR, which suggests significant changes in roughness or viscosity at the Bi/[BMIM] + solution interface. In situ XR performed on rhombohedral Bi (001) oriented films indicates extensive restructuring of the bismuth film cathodes takes place upon polarization to potentials more negative than -1.6 V vs. Ag/AgCl, which is characterized by a decrease of the Bi (001) Bragg peak intensity of ≥50% in [BMIM]OTf solutions in the presence and absence of CO 2. Over 90% of the reflectivity is recovered during the anodic half-scan, suggesting that the structural changes are mostly reversible. By contrast, such a phenomenon is not observed for thin Bi (001) oriented films in solutions of tetrabutylammonium salts that do not promote CO 2 reduction. In conclusion, these results highlight that Bi electrodes undergo significant potential-dependent chemical and structural transformations in the presence of [BMIM] + based electrolytes, including the reduction of bismuth oxide to bismuth metal, changes in roughness and near-surface viscosity.« less

  8. Design of N-Coordinated Dual-Metal Sites: A Stable and Active Pt-Free Catalyst for Acidic Oxygen Reduction Reaction.

    PubMed

    Wang, Jing; Huang, Zhengqing; Liu, Wei; Chang, Chunran; Tang, Haolin; Li, Zhijun; Chen, Wenxing; Jia, Chunjiang; Yao, Tao; Wei, Shiqiang; Wu, Yuen; Li, Yadong

    2017-12-06

    We develop a host-guest strategy to construct an electrocatalyst with Fe-Co dual sites embedded on N-doped porous carbon and demonstrate its activity for oxygen reduction reaction in acidic electrolyte. Our catalyst exhibits superior oxygen reduction reaction performance, with comparable onset potential (E onset , 1.06 vs 1.03 V) and half-wave potential (E 1/2 , 0.863 vs 0.858 V) than commercial Pt/C. The fuel cell test reveals (Fe,Co)/N-C outperforms most reported Pt-free catalysts in H 2 /O 2 and H 2 /air. In addition, this cathode catalyst with dual metal sites is stable in a long-term operation with 50 000 cycles for electrode measurement and 100 h for H 2 /air single cell operation. Density functional theory calculations reveal the dual sites is favored for activation of O-O, crucial for four-electron oxygen reduction.

  9. The relationship between health risks and health and productivity costs among employees at Pepsi Bottling Group.

    PubMed

    Henke, Rachel M; Carls, Ginger S; Short, Meghan E; Pei, Xiaofei; Wang, Shaohung; Moley, Susan; Sullivan, Mark; Goetzel, Ron Z

    2010-05-01

    To evaluate relationships between modifiable health risks and costs and measure potential cost savings from risk reduction programs. Health risk information from active Pepsi Bottling Group employees who completed health risk assessments between 2004 and 2006 (N = 11,217) were linked to medical care, workers' compensation, and short-term disability cost data. Ten health risks were examined. Multivariate analyses were performed to estimate costs associated with having high risk, holding demographics, and other risks constant. Potential savings from risk reduction were estimated. High risk for weight, blood pressure, glucose, and cholesterol had the greatest impact on total costs. A one-percentage point annual reduction in the health risks assessed would yield annual per capita savings of $83.02 to $103.39. Targeted programs that address modifiable health risks are expected to produce substantial cost reductions in multiple benefit categories.

  10. An empirical Bayes safety evaluation of tram/streetcar signal and lane priority measures in Melbourne.

    PubMed

    Naznin, Farhana; Currie, Graham; Sarvi, Majid; Logan, David

    2016-01-01

    Streetcars/tram systems are growing worldwide, and many are given priority to increase speed and reliability performance in mixed traffic conditions. Research related to the road safety impact of tram priority is limited. This study explores the road safety impacts of tram priority measures including lane and intersection/signal priority measures. A before-after crash study was conducted using the empirical Bayes (EB) method to provide more accurate crash impact estimates by accounting for wider crash trends and regression to the mean effects. Before-after crash data for 29 intersections with tram signal priority and 23 arterials with tram lane priority in Melbourne, Australia, were analyzed to evaluate the road safety impact of tram priority. The EB before-after analysis results indicated a statistically significant adjusted crash reduction rate of 16.4% after implementation of tram priority measures. Signal priority measures were found to reduce crashes by 13.9% and lane priority by 19.4%. A disaggregate level simple before-after analysis indicated reductions in total and serious crashes as well as vehicle-, pedestrian-, and motorcycle-involved crashes. In addition, reductions in on-path crashes, pedestrian-involved crashes, and collisions among vehicles moving in the same and opposite directions and all other specific crash types were found after tram priority implementation. Results suggest that streetcar/tram priority measures result in safety benefits for all road users, including vehicles, pedestrians, and cyclists. Policy implications and areas for future research are discussed.

  11. Non-linear quantization error reduction for the temperature measurement subsystem on-board LISA Pathfinder

    NASA Astrophysics Data System (ADS)

    Sanjuan, J.; Nofrarias, M.

    2018-04-01

    Laser Interferometer Space Antenna (LISA) Pathfinder is a mission to test the technology enabling gravitational wave detection in space and to demonstrate that sub-femto-g free fall levels are possible. To do so, the distance between two free falling test masses is measured to unprecedented sensitivity by means of laser interferometry. Temperature fluctuations are one of the noise sources limiting the free fall accuracy and the interferometer performance and need to be known at the ˜10 μK Hz-1/2 level in the sub-millihertz frequency range in order to validate the noise models for the future space-based gravitational wave detector LISA. The temperature measurement subsystem on LISA Pathfinder is in charge of monitoring the thermal environment at key locations with noise levels of 7.5 μK Hz-1/2 at the sub-millihertz. However, its performance worsens by one to two orders of magnitude when slowly changing temperatures are measured due to errors introduced by analog-to-digital converter non-linearities. In this paper, we present a method to reduce this effect by data post-processing. The method is applied to experimental data available from on-ground validation tests to demonstrate its performance and the potential benefit for in-flight data. The analog-to-digital converter effects are reduced by a factor between three and six in the frequencies where the errors play an important role. An average 2.7 fold noise reduction is demonstrated in the 0.3 mHz-2 mHz band.

  12. Non-linear quantization error reduction for the temperature measurement subsystem on-board LISA Pathfinder.

    PubMed

    Sanjuan, J; Nofrarias, M

    2018-04-01

    Laser Interferometer Space Antenna (LISA) Pathfinder is a mission to test the technology enabling gravitational wave detection in space and to demonstrate that sub-femto-g free fall levels are possible. To do so, the distance between two free falling test masses is measured to unprecedented sensitivity by means of laser interferometry. Temperature fluctuations are one of the noise sources limiting the free fall accuracy and the interferometer performance and need to be known at the ∼10 μK Hz -1/2 level in the sub-millihertz frequency range in order to validate the noise models for the future space-based gravitational wave detector LISA. The temperature measurement subsystem on LISA Pathfinder is in charge of monitoring the thermal environment at key locations with noise levels of 7.5 μK Hz -1/2 at the sub-millihertz. However, its performance worsens by one to two orders of magnitude when slowly changing temperatures are measured due to errors introduced by analog-to-digital converter non-linearities. In this paper, we present a method to reduce this effect by data post-processing. The method is applied to experimental data available from on-ground validation tests to demonstrate its performance and the potential benefit for in-flight data. The analog-to-digital converter effects are reduced by a factor between three and six in the frequencies where the errors play an important role. An average 2.7 fold noise reduction is demonstrated in the 0.3 mHz-2 mHz band.

  13. Electrochemical reduction of (U-40Pu-5Np)O 2 in molten LiCl electrolyte

    NASA Astrophysics Data System (ADS)

    Iizuka, Masatoshi; Sakamura, Yoshiharu; Inoue, Tadashi

    2006-12-01

    The electrochemical reduction of neptunium-containing MOX ((U-40Pu-5Np)O 2) was performed in molten lithium chloride melt at 923 K to investigate fundamental behavior of the transuranium elements and applicability of the method to reduction process for these materials. The Np-MOX was electrochemically reduced at the potential lower than -0.6 V vs. Bi-35 mol% Li reference electrode. The reduced metal grains in the surface region of the sample cohered with each other and made the layer of relatively high density, although it did not prevent the reduction of the sample toward the center. Complete reduction of the Np-MOX was shown by the weight change measurement through the electrochemical reduction and also by SEM-EDX observation. The chemical composition of the reduction products was homogeneous and agreed to that of the initial Np-MOX, which indicates that the reduction was completed and not selective among the actinides. The concentrations of the actinide elements, especially plutonium and americium in the electrolyte, increased with the progress of the tests, although their absolute values were very small. It is quite likely that plutonium and americium dissolve into the melt in the same manner as the lanthanide elements in the lithium reduction process.

  14. Reliable intraocular pressure measurement using automated radio-wave telemetry.

    PubMed

    Paschalis, Eleftherios I; Cade, Fabiano; Melki, Samir; Pasquale, Louis R; Dohlman, Claes H; Ciolino, Joseph B

    2014-01-01

    To present an autonomous intraocular pressure (IOP) measurement technique using a wireless implantable transducer (WIT) and a motion sensor. The WIT optical aid was implanted within the ciliary sulcus of a normotensive rabbit eye after extracapsular clear lens extraction. An autonomous wireless data system (AWDS) comprising of a WIT and an external antenna aided by a motion sensor provided continuous IOP readings. The sensitivity of the technique was determined by the ability to detect IOP changes resulting from the administration of latanoprost 0.005% or dorzolamide 2%, while the reliability was determined by the agreement between baseline and vehicle (saline) IOP. On average, 12 diurnal and 205 nocturnal IOP measurements were performed with latanoprost, and 26 diurnal and 205 nocturnal measurements with dorzolamide. No difference was found between mean baseline IOP (13.08±2.2 mmHg) and mean vehicle IOP (13.27±2.1 mmHg) (P=0.45), suggesting good measurement reliability. Both antiglaucoma medications caused significant IOP reduction compared to baseline; latanoprost reduced mean IOP by 10% (1.3±3.54 mmHg; P<0.001), and dorzolamide by 5% (0.62±2.22 mmHg; P<0.001). Use of latanoprost resulted in an overall twofold higher IOP reduction compared to dorzolamide (P<0.001). Repeatability was ±1.8 mmHg, assessed by the variability of consecutive IOP measurements performed in a short period of time (≤1 minute), during which the IOP is not expected to change. IOP measurements in conscious rabbits obtained without the need for human interactions using the AWDS are feasible and provide reproducible results.

  15. A follow-up study of the effects of early malnutrition on subsequent development. II. Fine motor skills in adolescence.

    PubMed

    Galler, J R; Ramsey, F; Solimano, G

    1985-06-01

    One hundred nine children, aged 8 through 15 yr, who suffered from malnutrition in the 1st yr of life and 107 well-nourished comparison children were tested for fine motor skills by the Purdue Pegboard test. The performance of index children was impaired on three of the four test measures. IQ measured concurrently showed a reduction in the index group; when the effects of IQ were eliminated, there was no longer any significant difference between index and comparison groups. The data suggest that the effects of early malnutrition on Pegboard performance are largely mediated by deficits in IQ. The presence of soft neurologic signs measured 4 yr earlier in the same children was highly correlated with reduced Pegboard performance, implying that early malnutrition has effects on nervous system function that are evident at least through 15 yr of age.

  16. [Metformin and changes in blood pressure and heart rate in lean patients with polycystic ovary syndrome (PCOS)--preliminary study].

    PubMed

    Tomczyk, Rita; Ociepka, Agnieszka; Kiałka, Marta; Milewicz, Tomasz; Migacz, Kamila; Kowalczuk, Aleksandra; Klocek, Marek

    2015-01-01

    The aim of our study was to assess the value of blood pressure and heart rate using the 24-hour blood pressure monitoring (ABPM) before and after treatment with metformin to patients with polycystic ovary syndrome (PCOS) and normal lean. 5 patients received metformin 1500 mg per day in three divided doses. ABPM was performed to each patient with PCOS twice: before and after 6 months of treatment with metformin. In patients with PCOS and normal lean after treatment with metformin we observed: statistically significant lower systolic blood pressure (120.2 ± 22.33 mmHg vs 113.22 ± 21.43 mm Hg, p = 0.0248); lower systolic blood pressure of daily measurements (127.1 ± 32.13 mmHg vs 116.1 ± 22.08 mmHg, p = 0.0062); reduction in average arterial pressure MAP in the measurement of the day (95.52 ± 22.76 mmHg vs 88.36 ± 16.41 mmHg, p = 0.048); oscillometric pressure reduction (96.27 ± 27.93 mmHg vs 87.82 ± 21.61, p = 0.0004 mmHg); oscillometric pressure reduction of daily measurements (102.1 ± 27.93 mmHg vs 91.85 ± 21.61 mmHg, p = 0.0032); oscillometric pressure reduction in the measure- ment of the night (88.81 ± 24.85 mmHg vs 82.22 ± 20.54 mmHg, p = 0.0089). In women after treatment with metformin has also been observed higher average heart rate (65.82 ± 13.48 / min vs. 70.71 ± 16.04 min; p < 0.01). The calculations included 500 measurements. Treatment with metformin in patients with PCOS and normal lean leads to lower blood pressure and increases the frequency of heart rate.

  17. Angular Impact Mitigation System for Bicycle Helmets to Reduce Head Acceleration and Risk of Traumatic Brain Injury

    PubMed Central

    Hansen, Kirk; Dau, Nathan; Feist, Florian; Deck, Caroline; Willinger, Rémy; Madey, Steven M.; Bottlang, Michael

    2013-01-01

    Angular acceleration of the head is a known cause of traumatic brain injury (TBI), but contemporary bicycle helmets lack dedicated mechanisms to mitigate angular acceleration. A novel Angular Impact Mitigation (AIM) system for bicycle helmets has been developed that employs an elastically suspended aluminum honeycomb liner to absorb linear acceleration in normal impacts as well as angular acceleration in oblique impacts. This study tested bicycle helmets with and without AIM technology to comparatively assess impact mitigation. Normal impact tests were performed to measure linear head acceleration. Oblique impact tests were performed to measure angular head acceleration and neck loading. Furthermore, acceleration histories of oblique impacts were analyzed in a computational head model to predict the resulting risk of TBI in the form of concussion and diffuse axonal injury (DAI). Compared to standard helmets, AIM helmets resulted in a 14% reduction in peak linear acceleration (p < 0.001), a 34% reduction in peak angular acceleration (p < 0.001), and a 22% to 32% reduction in neck loading (p < 0.001). Computational results predicted that AIM helmets reduced the risk of concussion and DAI by 27% and 44%, respectively. In conclusion, these results demonstrated that AIM technology could effectively improve impact mitigation compared to a contemporary expanded polystyrene-based bicycle helmet, and may enhance prevention of bicycle-related TBI. Further research is required. PMID:23770518

  18. Surgeon specialization and operative mortality in United States: retrospective analysis

    PubMed Central

    Dalton, Maurice; Cutler, David M; Birkmeyer, John D; Chandra, Amitabh

    2016-01-01

    Objective To measure the association between a surgeon’s degree of specialization in a specific procedure and patient mortality. Design Retrospective analysis of Medicare data. Setting US patients aged 66 or older enrolled in traditional fee for service Medicare. Participants 25 152 US surgeons who performed one of eight procedures (carotid endarterectomy, coronary artery bypass grafting, valve replacement, abdominal aortic aneurysm repair, lung resection, cystectomy, pancreatic resection, or esophagectomy) on 695 987 patients in 2008-13. Main outcome measure Relative risk reduction in risk adjusted and volume adjusted 30 day operative mortality between surgeons in the bottom quarter and top quarter of surgeon specialization (defined as the number of times the surgeon performed the specific procedure divided by his/her total operative volume across all procedures). Results For all four cardiovascular procedures and two out of four cancer resections, a surgeon’s degree of specialization was a significant predictor of operative mortality independent of the number of times he or she performed that procedure: carotid endarterectomy (relative risk reduction between bottom and top quarter of surgeons 28%, 95% confidence interval 0% to 48%); coronary artery bypass grafting (15%, 4% to 25%); valve replacement (46%, 37% to 53%); abdominal aortic aneurysm repair (42%, 29% to 53%); lung resection (28%, 5% to 46%); and cystectomy (41%, 8% to 63%). In five procedures (carotid endarterectomy, valve replacement, lung resection, cystectomy, and esophagectomy), the relative risk reduction from surgeon specialization was greater than that from surgeon volume for that specific procedure. Furthermore, surgeon specialization accounted for 9% (coronary artery bypass grafting) to 100% (cystectomy) of the relative risk reduction otherwise attributable to volume in that specific procedure. Conclusion For several common procedures, surgeon specialization was an important predictor of operative mortality independent of volume in that specific procedure. When selecting a surgeon, patients, referring physicians, and administrators assigning operative workload may want to consider a surgeon’s procedure specific volume as well as the degree to which a surgeon specializes in that procedure. PMID:27444190

  19. Speech understanding in background noise with the two-microphone adaptive beamformer BEAM in the Nucleus Freedom Cochlear Implant System.

    PubMed

    Spriet, Ann; Van Deun, Lieselot; Eftaxiadis, Kyriaky; Laneau, Johan; Moonen, Marc; van Dijk, Bas; van Wieringen, Astrid; Wouters, Jan

    2007-02-01

    This paper evaluates the benefit of the two-microphone adaptive beamformer BEAM in the Nucleus Freedom cochlear implant (CI) system for speech understanding in background noise by CI users. A double-blind evaluation of the two-microphone adaptive beamformer BEAM and a hardware directional microphone was carried out with five adult Nucleus CI users. The test procedure consisted of a pre- and post-test in the lab and a 2-wk trial period at home. In the pre- and post-test, the speech reception threshold (SRT) with sentences and the percentage correct phoneme scores for CVC words were measured in quiet and background noise at different signal-to-noise ratios. Performance was assessed for two different noise configurations (with a single noise source and with three noise sources) and two different noise materials (stationary speech-weighted noise and multitalker babble). During the 2-wk trial period at home, the CI users evaluated the noise reduction performance in different listening conditions by means of the SSQ questionnaire. In addition to the perceptual evaluation, the noise reduction performance of the beamformer was measured physically as a function of the direction of the noise source. Significant improvements of both the SRT in noise (average improvement of 5-16 dB) and the percentage correct phoneme scores (average improvement of 10-41%) were observed with BEAM compared to the standard hardware directional microphone. In addition, the SSQ questionnaire and subjective evaluation in controlled and real-life scenarios suggested a possible preference for the beamformer in noisy environments. The evaluation demonstrates that the adaptive noise reduction algorithm BEAM in the Nucleus Freedom CI-system may significantly increase the speech perception by cochlear implantees in noisy listening conditions. This is the first monolateral (adaptive) noise reduction strategy actually implemented in a mainstream commercial CI.

  20. Reduction of Left Visual Field Lexical Decision Accuracy as a Result of Concurrent Nonverbal Auditory Stimulation

    ERIC Educational Resources Information Center

    Van Strien, Jan W.

    2004-01-01

    To investigate whether concurrent nonverbal sound sequences would affect visual-hemifield lexical processing, lexical-decision performance of 24 strongly right-handed students (12 men, 12 women) was measured in three conditions: baseline, concurrent neutral sound sequence, and concurrent emotional sound sequence. With the neutral sequence,…

  1. 40 CFR 63.997 - Performance test and compliance assessment requirements for control devices.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... regulated materials are loaded, and samples shall be collected using integrated sampling or grab samples... material concentration and percent reduction may be measured as either total organic regulated material or... regulated material or TOC, sampling sites shall be located as specified in paragraphs (e)(2)(i)(A)(1) and (e...

  2. 40 CFR 63.997 - Performance test and compliance assessment requirements for control devices.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... regulated materials are loaded, and samples shall be collected using integrated sampling or grab samples... material concentration and percent reduction may be measured as either total organic regulated material or... regulated material or TOC, sampling sites shall be located as specified in paragraphs (e)(2)(i)(A)(1) and (e...

  3. 40 CFR 63.997 - Performance test and compliance assessment requirements for control devices.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... regulated materials are loaded, and samples shall be collected using integrated sampling or grab samples... material concentration and percent reduction may be measured as either total organic regulated material or... regulated material or TOC, sampling sites shall be located as specified in paragraphs (e)(2)(i)(A)(1) and (e...

  4. 40 CFR 63.865 - Performance test requirements and test methods.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... follows: ER18FE03.012 Where: ERSCCU = THC emission rate reported as carbon from each semichemical combustion unit, kg/Mg (lb/ton) of black liquor solids fired; THCmeas = Measured THC mass emission rate... semichemical combustion unit has selected the percentage reduction standards for THC, under § 63.862(c)(2)(ii...

  5. 40 CFR 63.865 - Performance test requirements and test methods.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Where: ERSCCU = THC emission rate reported as carbon from each semichemical combustion unit, kg/Mg (lb/ton) of black liquor solids fired; THCmeas = Measured THC mass emission rate reported as carbon, kg/hr... unit has selected the percentage reduction standards for THC, under § 63.862(c)(2)(ii), the percentage...

  6. 40 CFR 63.865 - Performance test requirements and test methods.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... follows: ER18FE03.012 Where: ERSCCU = THC emission rate reported as carbon from each semichemical combustion unit, kg/Mg (lb/ton) of black liquor solids fired; THCmeas = Measured THC mass emission rate... semichemical combustion unit has selected the percentage reduction standards for THC, under § 63.862(c)(2)(ii...

  7. Field testing of two prototype air-source integrated heat pumps for net zero energy home (nZEH) application

    DOE PAGES

    Baxter, Van D.; Munk, Jeffrey D.

    2017-11-08

    By integrating multiple functions into a single system it offers potential efficiency and cost reduction benefits. Oak Ridge National Laboratory (ORNL) and its partners have designed, developed, and tested two air-source heat pump designs that not only provide space heating and cooling, but also water heating, dehumidification, and ventilation functions. Some details on the design, simulated performance, prototype field test, measured performance, and lessons learned are provided.

  8. Voltammetric Characterization of Soluble Polyacetylene Derivatives Obtained from the Ring-Opening Metathesis Polymerization (ROMP) of Substituted Cyclooctatetraenes

    DTIC Science & Technology

    1993-01-15

    emct ,t ,n electrochemical cis-trans isomerization on the first voltammetric sweep through either reductive or doping. Spectroelectrochemical studies...predominantly- cis poly-RCOT films was irreversible, and indicated the presence of an electrochemical cis-trans isomerization on the first voltammetric sweep ...electrochemical measurements were performed under N2(g) in a Vacuum Atmospheres dry box. Cyclic voltametry was performed using a 3-electrode configuration in a l

  9. Field testing of two prototype air-source integrated heat pumps for net zero energy home (nZEH) application

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baxter, Van D.; Munk, Jeffrey D.

    By integrating multiple functions into a single system it offers potential efficiency and cost reduction benefits. Oak Ridge National Laboratory (ORNL) and its partners have designed, developed, and tested two air-source heat pump designs that not only provide space heating and cooling, but also water heating, dehumidification, and ventilation functions. Some details on the design, simulated performance, prototype field test, measured performance, and lessons learned are provided.

  10. Further development and testing of the metabolic gas analyzer

    NASA Technical Reports Server (NTRS)

    1973-01-01

    Continued development of a metabolic monitor utilizing a mass spectrometer and digital computer to perform measurements and data reduction, is reported. The device prints-out breath-by-breath values for 02 consumption, C02 production, minute volume and tidal volume. The flow is measured by introduction of a tracer gas to the expired gas stream. Design modifications to reduce pressure drop in the flow splitter to one inch of water at 600 liters/min flow and to extend the range of linear flow measurement to 1000 liters/min are discussed.

  11. Experimental investigation of shock-cell noise reduction for single-stream nozzles in simulated flight, comprehensive data report. Volume 2: Laser velocimeter data

    NASA Technical Reports Server (NTRS)

    Yamamoto, K.; Brausch, J. F.; Janardan, B. A.; Hoerst, D. J.; Price, A. O.; Knott, P. R.

    1984-01-01

    Mean velocity (axial component) and turbulent velocity (axial component) measurements for thirty one selected flow conditions of six models were performed employing the Laser Doppler Velocimeter Aerodynamic conditions which define the test points are given. Tabulations which explain the scope of mean velocity traverses and turbulence histogram measurements are also presented. The actual LV position, the type of traverse, and measured mean and turbulent velocities along copies of the LV mean velocity traces are contained.

  12. Wind-tunnel measurement of noise emitted by helicopter rotors at high speed

    NASA Astrophysics Data System (ADS)

    Prieur, J.

    Measurements of high-speed impulsive helicopter rotor noise in a wind-tunnel are presented. High-speed impulsive noise measurements have been performed in 1988 in the ONERA S2ch wind-tunnel, fitted with an acoustic lining, on two types of rotors. They show that substantial noise reduction is obtained with sweptback tips, initially designed for aerodynamic purposes, which lower transonic effects on the advancing blade tip. Emphasis is placed on the necessity of taking into account the acoustic annoyance problem, using noise prediction tools, when designing new helicopter blades.

  13. MICRODOSIMETRIC MEASUREMENT OF SECONDARY RADIATION IN THE PASSIVE SCATTERED PROTON THERAPY ROOM OF iTHEMBA LABS USING A TISSUE-EQUIVALENT PROPORTIONAL COUNTER.

    PubMed

    Chiriotti, S; Parisi, A; Vanhavere, F; De Saint-Hubert, M; Vandevoorde, C; Slabbert, J; Beukes, P; de Kock, E; Symons, J

    2018-04-13

    Measurements of the dose equivalent at different distances from the isocenter of the proton therapy center at iThemba LABS were previously performed with a tissue-equivalent proportional counter (TEPC). These measurements showed that the scattered radiation levels were one or two orders of magnitude higher in comparison to other passive scattering delivery systems. In order to reduce these radiation levels, additional shielding was installed shortly after the measurements were done. Therefore, the aim of this work is to quantify and assess the reduction of the secondary doses delivered in the proton therapy room at iThemba LABS after the installation of the additional shielding. This has been performed by measuring microdosimetric spectra with a TEPC at 11 locations around the isocenter when a clinical modulated beam of 200 MeV proton was impinging onto a water phantom placed at the isocenter.

  14. Daily personal exposure to black carbon: A pilot study

    NASA Astrophysics Data System (ADS)

    Williams, Ryan D.; Knibbs, Luke D.

    2016-05-01

    Continuous personal monitoring is the benchmark for air pollution exposure assessment. Black carbon (BC) is a strong marker of primary combustion like vehicle and biomass emissions. There have been few studies that quantified daily personal BC exposure and the contribution that different microenvironments make to it. In this pilot study, we used a portable aethalometer to measure BC concentrations in an individual's breathing zone at 30-s intervals while he performed his usual daily activities. We used a GPS and time-activity diary to track where he spent his time. We performed twenty 24-h measurements, and observed an arithmetic mean daily exposure concentration of 603 ng/m3. We estimated that changing commute modes from bus to train reduced the 24-h mean BC exposure concentration by 29%. Switching from open windows to closed windows and recirculated air in a car led to a reduction of 32%. Living in a home without a wood-fired heater caused a reduction of 50% compared with a wood-heated home. Our preliminary findings highlight the potential utility of simple approaches to reduce a person's daily BC exposure.

  15. Porous Carbon-Hosted Atomically Dispersed Iron-Nitrogen Moiety as Enhanced Electrocatalysts for Oxygen Reduction Reaction in a Wide Range of pH

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fu, Shaofang; Zhu, Chengzhou; Su, Dong

    As one of the alternatives to replace precious metal catalysts, transition-metal–nitrogen–carbon (M–N–C) electrocatalysts have attracted great research interest due to their low cost and good catalytic activities. Despite nanostructured M–N–C catalysts can achieve good electrochemical perfor-mances, they are vulnerable to aggregation and insufficient catalytic sites upon continuous catalytic reaction. In this work, metal–organic frameworks derived porous single-atom electrocatalysts (SAEs) were successfully prepared by simple pyrolysis procedure without any further posttreatment. Combining the X-ray absorption near-edge spectroscopy and electrochemical measure-ments, the SAEs have been identified with superior oxygen reduction reaction (ORR) activity and stability compared with Pt/C catalysts in alkaline condition.more » More impressively, the SAEs also show excellent ORR electrocatalytic perfor-mance in both acid and neutral media. This study of nonprecious catalysts provides new insights on nanoengineering catalytically active sites and porous structures for nonprecious metal ORR catalysis in a wide range of pH.« less

  16. Porous Carbon-Hosted Atomically Dispersed Iron–Nitrogen Moiety as Enhanced Electrocatalysts for Oxygen Reduction Reaction in a Wide Range of pH

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fu, Shaofang; Zhu, Chengzhou; Su, Dong

    2018-02-01

    As one of the alternatives to replace precious metal catalysts, transition-metal–nitrogen–carbon (M–N–C) electrocatalysts have attracted great research interest due to their low cost and good catalytic activities. Despite nanostructured M–N–C catalysts can achieve good electrochemical perfor-mances, they are vulnerable to aggregation and insufficient catalytic sites upon continuous catalytic reaction. In this work, metal–organic frameworks derived porous single-atom electrocatalysts (SAEs) were successfully prepared by simple pyrolysis procedure without any further posttreatment. Combining the X-ray absorption near-edge spectroscopy and electrochemical measure-ments, the SAEs have been identified with superior oxygen reduction reaction (ORR) activity and stability compared with Pt/C catalysts in alkaline condition.more » More impressively, the SAEs also show excellent ORR electrocatalytic perfor-mance in both acid and neutral media. This study of nonprecious catalysts provides new insights on nanoengineering catalytically active sites and porous structures for nonprecious metal ORR catalysis in a wide range of pH.« less

  17. Measuring the benefit of orthophosphate treatment on lead in drinking water.

    PubMed

    Cardew, P T

    2009-03-01

    Many water companies are adding low concentrations of orthophosphate to the water supply in order to reduce lead concentrations in drinking water produced from corrosion of lead service pipes. Despite the erratic nature of lead concentrations measured at customer properties it has been possible to quantify the impact of treatment on lead concentrations and thereby quantify the effectiveness of treatment at both a regional and zonal level. This showed that the treatment policy has delivered more than 90 per cent reduction in lead concentrations, and was largely in accordance with theory. Across the region, lead performance and the reduction in lead performance show significant variation. A large part of this variation can be accounted for by variations in the proportion of leaded properties supplied through lead service pipes. Analysis showed that the proportion of particulate lead has also reduced significantly over the last decade. This is attributed to improved mechanical robustness of the corrosion layer caused by changes in its physical structure. This appears to be a very slow process with a natural time-scale of years.

  18. Differences in Neuropsychological Functioning Between Homicidal and Nonviolent Schizophrenia Samples.

    PubMed

    Stratton, John; Cobia, Derin J; Reilly, James; Brook, Michael; Hanlon, Robert E

    2018-02-07

    Few studies have compared performance on neurocognitive measures between violent and nonviolent schizophrenia samples. A better understanding of neurocognitive dysfunction in violent individuals with schizophrenia could increase the efficacy of violence reduction strategies and aid in risk assessment and adjudication processes. This study aimed to compare neuropsychological performance between 25 homicide offenders with schizophrenia and 25 nonviolent schizophrenia controls. The groups were matched for age, race, sex, and handedness. Independent t-tests and Mann-Whitney U-tests were used to compare the schizophrenia groups' performance on measures of cognition, including composite scores assessing domain level functioning and individual neuropsychological tests. Results indicated the violent schizophrenia group performed worse on measures of memory and executive functioning, and the Intellectual Functioning composite score, when compared to the nonviolent schizophrenia sample. These findings replicate previous research documenting neuropsychological deficits specific to violent individuals with schizophrenia and support research implicating fronto-limbic dysfunction among violent offenders with schizophrenia. © 2018 American Academy of Forensic Sciences.

  19. An Assessment of NASA Glenn's Aeroacoustic Experimental and Predictive Capabilities for Installed Cooling Fans

    NASA Technical Reports Server (NTRS)

    Koch, L. Danielle; VanZante, Dale E.; Wernet, Mark P.; Podboy, Gary G.

    2006-01-01

    Quiet, high performance electronics cooling fans are needed for both commercial applications and future manned space exploration missions. Researchers at NASA Glenn focusing on aircraft engine noise, have long been familiar with the challenge of reducing fan noise without sacrificing aerodynamic performance. Is it possible to capitalize on the lessons-learned in aircraft engine noise reduction to identify inexpensive ways to improve the aerodynamic and acoustic performance of electronics cooling fans? Recent tests at NASA Glenn have begun to look for answers to this question. The overall aerodynamic and acoustic performance of a commercially available, spaceflight qualified 80 mm diameter axial flow fan has been measured using an automated plenum in accordance with ISO 10302 in the hemi-anechoic chamber of NASA Glenn s Acoustical Testing Laboratory. These measurements are complemented by detailed aerodynamic measurements of the inlet, exhaust, and rotor wake regions of the fan using Particle Image Velocimetry and hot-wire probes. A study of preliminary results yielded recommendations for system designers, fan manufacturers, and researchers.

  20. Swallowing performance in patients with head and neck cancer: a simple clinical test.

    PubMed

    Patterson, Joanne M; McColl, Elaine; Carding, Paul N; Kelly, Charles; Wilson, Janet A

    2009-10-01

    Few simple clinical measures are available to monitor swallowing performance in head and neck cancer. Water swallow tests (WST) have been used as a part of clinical assessments in neurological dysphagia. The aim of this paper is to evaluate the utility of the 100 mL WST in head and neck cancer patients. The 100 mL WST was performed on 167 head and neck cancer patients. Measures were compared with respect to tumor site/stage, gender and age. The cohort was compared with published healthy controls. The test was quick to administer with excellent compliance. Patients had significantly poorer swallows than the published control group (mean reduction 1.6 mL/s). Function worsened with increased tumor stage and for patients with pharyngeal tumors. The 100 mL WST is an effective swallowing performance measure and is easily incorporated into a clinical examination. This paper provides benchmark data on the 100 mL WST for individuals with head and neck cancer.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Medina-Ramos, Jonnathan; Lee, Sang Soo; Fister, Timothy T.

    Real-time changes in the composition and structure of bismuth electrodes used for catalytic conversion of CO 2 into CO were examined via X-ray absorption spectroscopy (including XANES and EXAFS), electrochemical quartz crystal microbalance (EQCM) and in situ X-ray reflectivity (XR). Measurements were performed with bismuth electrodes immersed in acetonitrile (MeCN) solutions containing a 1-butyl-3-methylimidazolium ([BMIM] +) ionic liquid promoter or electrochemically inactive tetrabutylammonium supporting electrolytes (TBAPF 6 or TBAOTf). Altogether, these measurements show that bismuth electrodes are originally a mixture of bismuth oxides (including Bi 2O 3) and metallic bismuth (Bi 0), and that the reduction of oxidized bismuth speciesmore » to Bi 0 is fully achieved under potentials at which CO 2 activation takes place. Furthermore, EQCM measurements conducted during cyclic voltammetry revealed that a bismuth-coated quartz crystal exhibits significant shifts in resistance (ΔR) prior to the onset of CO 2 reduction near -1.75 V vs. Ag/AgCl and pronounced hysteresis in frequency (Δf) and ΔR, which suggests significant changes in roughness or viscosity at the Bi/[BMIM] + solution interface. In situ XR performed on rhombohedral Bi (001) oriented films indicates extensive restructuring of the bismuth film cathodes takes place upon polarization to potentials more negative than -1.6 V vs. Ag/AgCl, which is characterized by a decrease of the Bi (001) Bragg peak intensity of ≥50% in [BMIM]OTf solutions in the presence and absence of CO 2. Over 90% of the reflectivity is recovered during the anodic half-scan, suggesting that the structural changes are mostly reversible. By contrast, such a phenomenon is not observed for thin Bi (001) oriented films in solutions of tetrabutylammonium salts that do not promote CO 2 reduction. In conclusion, these results highlight that Bi electrodes undergo significant potential-dependent chemical and structural transformations in the presence of [BMIM] + based electrolytes, including the reduction of bismuth oxide to bismuth metal, changes in roughness and near-surface viscosity.« less

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Medina-Ramos, Jonnathan; Lee, Sang Soo; Fister, Timothy T.

    Real-time changes in the composition and structure of bismuth electrodes used for catalytic conversion of CO2 into CO were examined via X-ray absorption spectroscopy (including XANES and EXAFS), electrochemical quartz crystal microbalance (EQCM), and in situ X-ray reflectivity (XR). Measurements were performed with bismuth electrodes immersed in acetonitrile (MeCN) solutions containing a 1-butyl-3-methylimidazolium ([BMIM]+) ionic liquid promoter or electrochemically inactive tetrabutylammonium supporting electrolytes (TBAPF6 and TBAOTf). Altogether, these measurements show that bismuth electrodes are originally a mixture of bismuth oxides (including Bi2O3) and metallic bismuth (Bi0) and that the reduction of oxidized bismuth species to Bi0 is fully achieved undermore » potentials at which CO2 activation takes place. Furthermore, EQCM measurements conducted during cyclic voltammetry revealed that a bismuth-coated quartz crystal exhibits significant shifts in resistance (ΔR) prior to the onset of CO2 reduction near -1.75 V vs Ag/AgCl and pronounced hysteresis in frequency (Δf) and ΔR, which suggests significant changes in roughness or viscosity at the Bi/[BMIM]+ solution interface. In situ XR performed on rhombohedral Bi (001) oriented films indicates that extensive restructuring of the bismuth film cathodes takes place upon polarization to potentials more negative than -1.6 V vs Ag/AgCl, which is characterized by a decrease of the Bi (001) Bragg peak intensity of ≥50% in [BMIM]OTf solutions in the presence and absence of CO2. Over 90% of the reflectivity is recovered during the anodic half-scan, suggesting that the structural changes are mostly reversible. In contrast, such a phenomenon is not observed for thin Bi (001) oriented films in solutions of tetrabutylammonium salts that do not promote CO2 reduction. Overall, these results highlight that Bi electrodes undergo significant potential-dependent chemical and structural transformations in the presence of [BMIM]+-based electrolytes, including the reduction of bismuth oxide to bismuth metal and changes in roughness and near-surface viscosity.« less

  3. Can task-switching training enhance executive control functioning in children with attention deficit/-hyperactivity disorder?

    PubMed

    Kray, Jutta; Karbach, Julia; Haenig, Susann; Freitag, Christine

    2011-01-01

    The key cognitive impairments of children with attention deficit/-hyperactivity disorder (ADHD) include executive control functions such as inhibitory control, task-switching, and working memory (WM). In this training study we examined whether task-switching training leads to improvements in these functions. Twenty children with combined type ADHD and stable methylphenidate medication performed a single-task and a task-switching training in a crossover training design. The children were randomly assigned to one of two groups. One group started with the single-task training and then performed the task-switching training and the other group vice versa. The effectiveness of the task-switching training was measured as performance improvements (relative to the single-task training) on a structurally similar but new switching task and on other executive control tasks measuring inhibitory control and verbal WM as well as on fluid intelligence (reasoning). The children in both groups showed improvements in task-switching, that is, a reduction of switching costs, but not in performing the single-tasks across four training sessions. Moreover, the task-switching training lead to selective enhancements in task-switching performance, that is, the reduction of task-switching costs was found to be larger after task-switching than after single-task training. Similar selective improvements were observed for inhibitory control and verbal WM, but not for reasoning. Results of this study suggest that task-switching training is an effective cognitive intervention that helps to enhance executive control functioning in children with ADHD.

  4. Can Task-Switching Training Enhance Executive Control Functioning in Children with Attention Deficit/-Hyperactivity Disorder?

    PubMed Central

    Kray, Jutta; Karbach, Julia; Haenig, Susann; Freitag, Christine

    2012-01-01

    The key cognitive impairments of children with attention deficit/-hyperactivity disorder (ADHD) include executive control functions such as inhibitory control, task-switching, and working memory (WM). In this training study we examined whether task-switching training leads to improvements in these functions. Twenty children with combined type ADHD and stable methylphenidate medication performed a single-task and a task-switching training in a crossover training design. The children were randomly assigned to one of two groups. One group started with the single-task training and then performed the task-switching training and the other group vice versa. The effectiveness of the task-switching training was measured as performance improvements (relative to the single-task training) on a structurally similar but new switching task and on other executive control tasks measuring inhibitory control and verbal WM as well as on fluid intelligence (reasoning). The children in both groups showed improvements in task-switching, that is, a reduction of switching costs, but not in performing the single-tasks across four training sessions. Moreover, the task-switching training lead to selective enhancements in task-switching performance, that is, the reduction of task-switching costs was found to be larger after task-switching than after single-task training. Similar selective improvements were observed for inhibitory control and verbal WM, but not for reasoning. Results of this study suggest that task-switching training is an effective cognitive intervention that helps to enhance executive control functioning in children with ADHD. PMID:22291628

  5. Effectiveness of nonporous windscreens for infrasonic measurements.

    PubMed

    Dauchez, Nicolas; Hayot, Maxime; Denis, Stéphane

    2016-06-01

    This paper deals with nonporous windscreens used for reducing noise in infrasonic measurements. A model of sound transmission using a modal approach is derived. The system is a square plate coupled with a cavity. The model agrees with finite element simulations and measurements performed on two windscreens: a cubic windscreen using a material recommended by Shams, Zuckerwar, and Sealey [J. Acoust. Soc. Am. 118, 1335-1340 (2005)] and an optimized flat windscreen made out of aluminum. Only the latter was found to couple acoustical waves below 10 Hz without any attenuation. Moreover, wind noise reduction measurements show that nonporous windscreens perform similarly as a pipe array by averaging the pressure fluctuations. These results question the assumptions of Shams et al. and Zuckerwar [J. Acoust. Soc. Am. 127, 3327-3334 (2010)] about compact nonporous windscreens design and effectiveness.

  6. Aerodynamic drag reduction tests on a full-scale tractor-trailer combination with several add-on devices

    NASA Technical Reports Server (NTRS)

    Montoya, L. C.; Steers, L. L.

    1974-01-01

    Aerodynamic drag tests were performed on a conventional cab-over-engine tractor with a 45-foot trailer and five commercially available or potentially available add-on devices using the coast-down method. The tests ranged in velocity from approximately 30 miles per hour to 65 miles per hour and included some flow visualization. A smooth, level runway at Edwards Air Force Base was used for the tests, and deceleration measurements were taken with both accelerometers and stopwatches. An evaluation of the drag reduction results obtained with each of the five add-on devices is presented.

  7. Study on preparation of ultrafine amorphous particles by chemical reduction

    NASA Astrophysics Data System (ADS)

    Song, Xu; Yusheng, Xu; Huali, Jiang; Qing, Xue

    1993-04-01

    Ultrafine amorphous FeNiB powder was prepared by potassium borohydride reduction by mixing the aqueous solutions in a bath of supersonic oscillator. Different mixing ratios of potassium borohydride to metal salt were applied. Analysis of the composition of the sample and the Fe 2+ and Ni 2+ remaining in the filtrate after preparation shows that a quantity of KBH 4 about 1.5 times the stoichiometrical quantity is enough. Mössbauer measurements were performed at room temperature and it was found that excess KBH 4 makes no distinct difference in the spectra of the samples.

  8. An experimental investigation of internal area ruling for transonic and supersonic channel flow

    NASA Technical Reports Server (NTRS)

    Roberts, W. B.; Vanrintel, H. L.; Rizvi, G.

    1982-01-01

    A simulated transonic rotor channel model was examined experimentally to verify the flow physics of internal area ruling. Pressure measurements were performed in the high speed wind tunnel at transonic speeds with Mach 1.5 and Mach 2 nozzle blocks to get an indication of the approximate shock losses. The results showed a reduction in losses due to internal area ruling with the Mach 1.5 nozzle blocks. The reduction in total loss coefficient was of the order of 17 percent for a high blockage model and 7 percent for a cut-down model.

  9. [Effectiveness of intensive group psychotherapy in treatment of neurotic and personality disorders].

    PubMed

    Mielimąka, Michał; Rutkowski, Krzysztof; Cyranka, Katarzyna; Sobański, Jerzy; Müldner-Nieckowski, Łukasz; Dembińska, Edyta; Smiatek-Mazgaj, Bogna; Klasa, Katarzyna

    2015-01-01

    The aim of this study was to analyze the effectiveness of intensive (150 - 210 sessions), short-term (10 - 14 weeks) group psychotherapy in the treatment of neurotic disorders, and selected personality disorders. The study involved 145 patients treated in day hospital due to neurotic disorders and selected personality disorders. The measurements were performed twice - at the beginning and at the end of hospitalization. The effectiveness of psychotherapy in the reduction of symptoms of neurotic disorders was measured with symptom checklist "0". The change in the severity of personality traits characteristic for neurotic disorders was examined using Neurotic Personality Questionnaire KON-2006. A significant reduction in symptoms of neurotic disorders was found in 84% of patients (85,7% women and 80,8% men). 70,3% of the examined patients obtained in the measurement at the end of treatment results indicating the level of severity of neurotic disorders symptoms below the cutoff point separating population of healthy individuals from patients. A significant reduction in the severity of personality traits characteristically occurring in patients suffering from neurotic disorders was found in 76% of patients (74.5% women and 78.7% men). 42.8% of the examined patients obtained in the measurement at the end of the treatment the value of neurotic personality traits index (X-KON) typical for healthy population. Intensive, short-term group psychotherapy with elements of individual therapy is an effective treatment for neurotic disorders. The majority of treated persons obtains a significant symptomatic improvement and a reduction in the severity of neurotic personality traits.

  10. Finding Order within the Chaos of Counternarcotics: A Universal Framework for the Reduction of Illicit Crop Cultivation

    DTIC Science & Technology

    2013-12-13

    components can be part of multiple systems simultaneously. Measures of effectiveness determine how well a certain action is meeting its operational...have been collected throughout this literature review as well as during the analysis of data in chapter 4. Performance measures allow for an...for analysis as well . Eradication, however, can occur throughout the year. This is particularly true in South America, because coca can be harvested

  11. Data Reduction Pipeline for the CHARIS Integral-Field Spectrograph I: Detector Readout Calibration and Data Cube Extraction

    NASA Technical Reports Server (NTRS)

    Groff, Tyler; Rizzo, Maxime; Greco, Johnny P.; Loomis, Craig; Mede, Kyle; Kasdin, N. Jeremy; Knapp, Gillian; Tamura, Motohide; Hayashi, Masahiko; Galvin, Michael; hide

    2017-01-01

    We present the data reduction pipeline for CHARIS, a high-contrast integral-field spectrograph for the Subaru Telescope. The pipeline constructs a ramp from the raw reads using the measured nonlinear pixel response and reconstructs the data cube using one of three extraction algorithms: aperture photometry, optimal extraction, or chi-squared fitting. We measure and apply both a detector flatfield and a lenslet flatfield and reconstruct the wavelength- and position-dependent lenslet point-spread function (PSF) from images taken with a tunable laser. We use these measured PSFs to implement a chi-squared-based extraction of the data cube, with typical residuals of approximately 5 percent due to imperfect models of the under-sampled lenslet PSFs. The full two-dimensional residual of the chi-squared extraction allows us to model and remove correlated read noise, dramatically improving CHARIS's performance. The chi-squared extraction produces a data cube that has been deconvolved with the line-spread function and never performs any interpolations of either the data or the individual lenslet spectra. The extracted data cube also includes uncertainties for each spatial and spectral measurement. CHARIS's software is parallelized, written in Python and Cython, and freely available on github with a separate documentation page. Astrometric and spectrophotometric calibrations of the data cubes and PSF subtraction will be treated in a forthcoming paper.

  12. Data reduction pipeline for the CHARIS integral-field spectrograph I: detector readout calibration and data cube extraction

    NASA Astrophysics Data System (ADS)

    Brandt, Timothy D.; Rizzo, Maxime; Groff, Tyler; Chilcote, Jeffrey; Greco, Johnny P.; Kasdin, N. Jeremy; Limbach, Mary Anne; Galvin, Michael; Loomis, Craig; Knapp, Gillian; McElwain, Michael W.; Jovanovic, Nemanja; Currie, Thayne; Mede, Kyle; Tamura, Motohide; Takato, Naruhisa; Hayashi, Masahiko

    2017-10-01

    We present the data reduction pipeline for CHARIS, a high-contrast integral-field spectrograph for the Subaru Telescope. The pipeline constructs a ramp from the raw reads using the measured nonlinear pixel response and reconstructs the data cube using one of three extraction algorithms: aperture photometry, optimal extraction, or χ2 fitting. We measure and apply both a detector flatfield and a lenslet flatfield and reconstruct the wavelength- and position-dependent lenslet point-spread function (PSF) from images taken with a tunable laser. We use these measured PSFs to implement a χ2-based extraction of the data cube, with typical residuals of ˜5% due to imperfect models of the undersampled lenslet PSFs. The full two-dimensional residual of the χ2 extraction allows us to model and remove correlated read noise, dramatically improving CHARIS's performance. The χ2 extraction produces a data cube that has been deconvolved with the line-spread function and never performs any interpolations of either the data or the individual lenslet spectra. The extracted data cube also includes uncertainties for each spatial and spectral measurement. CHARIS's software is parallelized, written in Python and Cython, and freely available on github with a separate documentation page. Astrometric and spectrophotometric calibrations of the data cubes and PSF subtraction will be treated in a forthcoming paper.

  13. On-line pre-reduction of Se(VI) by thiourea for selenium speciation by hydride generation

    NASA Astrophysics Data System (ADS)

    Qiu, Jianhua; Wang, Qiuquan; Ma, Yuning; Yang, Limin; Huang, Benli

    2006-07-01

    In this study, thiourea (TU) was novelly developed as a reduction reagent for on-line pre-reduction of selenium(VI) before conventional hydride generation (HG) by KBH 4/NaOH-HCl. After TU on-line pre-reduction, the HG efficiency of Se(VI) has been greatly improved and because even higher than that of the same amount of Se(IV) obtained in the conventional HG system. The possible pre-reduction mechanism is discussed. The detection limit (DL) of selenate reaches 10 pg mL - 1 when using on-line TU pre-reduction followed by HG atomic fluorescence detection. When TU pre-reduction followed by HG is used as an interface between ion-pair high performance liquid chromatography and atomic fluorescence spectrometry, selenocystine, selenomethionine, selenite and selenate can be measured simultaneously and quantitatively. The DLs of these are 0.06, 0.08, 0.05 and 0.04 ng mL - 1 , respectively, and the relative standard deviations of 9 duplicate runs for all the 4 species are less than 5%. Furthermore, it was successfully applied to Se speciation analysis of cultured garlic samples, and validated by determination of total selenium and selenium species in certified reference material NIST 1946.

  14. Effectiveness of patient empowerment over stress related to knee arthroplasty surgery.

    PubMed

    Garzón-Rey, Jorge Mario; Arza-Valdés, Adriana; Nuevo-Gayoso, Montserrat; Aguiló, Jordi

    This study aims to show evidence of the Empowerment Session's effectiveness through measurements of surgery related emotional stress before and after this session. The study was performed on 41 patients with knee arthroplasty surgery prescription by measuring the evolution of their emotional stress generated by surgery expectative, during the empowerment session. Two sets of measurements per patient were performed, before and after the empowerment session. Each set consisted of recording an electrocardiogram for 10min while the patients were seated and then applying two standard psychometric tests: State-Trait Anxiety Inventory test and Visual Analog Stress test. Differences in emotional stress were analyzed using psychometric tests and heart rate variability (HRV) analysis as stress biomarkers. Psychometric stress measurement shows a 17.8% reduction in stress according to the total stress scale value, and a 41.9% reduction in stress between test results before and after the session. Mean heart rate values increased by 7.4% with respect to the initial values, very low frequency power and total power also change in value suggesting more sympathetic and less parasympathetic activity. Both psychological and physiological measurements suggest the effectiveness of the empowerment session due to a significant increase in the wellness state of patients. Additionally, the correlation between psychometric tests and HRV indices demonstrates that both emotional stress indicators could be used as feedback on the empowerment sessions or as a reference to enhance surgical outcomes. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  15. Cardiac and Vascular Responses to Thigh Cuffs and Respiratory Maneuvers on Crewmembers of the International Space Station

    NASA Technical Reports Server (NTRS)

    Hamilton, Douglas; Sargsyan, Ashot E.; Garcia, Kathleen; Ebert, Douglas; Whitson, Peggy A.; Feiveson, Alan; Alferova, Irina V.; Dulchavsky, Scott A.; Matveev, Vladimir P.; Bogomolov, Valery V.; hide

    2011-01-01

    The transition to microgravity eliminates the hydrostatic gradients in the vascular system. The resulting fluid redistribution commonly manifests as facial edema, engorgement of the external neck veins, and a decrease in leg diameter. This experiment examined the responses to modified Valsalva and Mueller maneuvers measured by cardiac and vascular ultrasound (ECHO) in a baseline steady state and during preload reduction introduced with thigh occlusion cuffs used as a counter-measure device (Braslet cuffs) measured by cardiac and vascular ultrasound examinations. Methods: Nine International Space Station crewmember subjects (Expeditions 16 - 20) were examined in 15 experiment sessions 101 +/- 46.days after launch (mean +/- SD; 33 - 185). Twenty Seven cardiac and vascular parameters were obtained with/without respiratory maneuvers before and after tightening of the Braslet cuffs. Results: Non-physicians performed diagnostic-quality cardiac and vascular ultrasound examinations using remote guidance. Three of 27 combinations of maneuvers and Braslet or Braslet alone were identified as being significant changed when compared to baseline. Eleven of 81 differences between combinations of Mueller, Valsalva or baseline were significant and related to cardiac preload reduction or increase in lower extremity venous volume. Conclusions: Acute application of Braslet occlusion cuffs causes lower extremity fluid sequestration and exerts commensurate measurable effects on cardiac performance in microgravity. Ultrasound techniques to measure the hemodynamic effects of thigh cuffs in combination with respiratory maneuvers may serve as an invaluable tool in determining the volume status of the cardiac patient at the 'microgravity bedside'.

  16. TH-A-18C-03: Noise Correlation in CBCT Projection Data and Its Application for Noise Reduction in Low-Dose CBCT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    ZHANG, H; Huang, J; Ma, J

    2014-06-15

    Purpose: To study the noise correlation properties of cone-beam CT (CBCT) projection data and to incorporate the noise correlation information to a statistics-based projection restoration algorithm for noise reduction in low-dose CBCT. Methods: In this study, we systematically investigated the noise correlation properties among detector bins of CBCT projection data by analyzing repeated projection measurements. The measurements were performed on a TrueBeam on-board CBCT imaging system with a 4030CB flat panel detector. An anthropomorphic male pelvis phantom was used to acquire 500 repeated projection data at six different dose levels from 0.1 mAs to 1.6 mAs per projection at threemore » fixed angles. To minimize the influence of the lag effect, lag correction was performed on the consecutively acquired projection data. The noise correlation coefficient between detector bin pairs was calculated from the corrected projection data. The noise correlation among CBCT projection data was then incorporated into the covariance matrix of the penalized weighted least-squares (PWLS) criterion for noise reduction of low-dose CBCT. Results: The analyses of the repeated measurements show that noise correlation coefficients are non-zero between the nearest neighboring bins of CBCT projection data. The average noise correlation coefficients for the first- and second- order neighbors are about 0.20 and 0.06, respectively. The noise correlation coefficients are independent of the dose level. Reconstruction of the pelvis phantom shows that the PWLS criterion with consideration of noise correlation (PWLS-Cor) results in a lower noise level as compared to the PWLS criterion without considering the noise correlation (PWLS-Dia) at the matched resolution. Conclusion: Noise is correlated among nearest neighboring detector bins of CBCT projection data. An accurate noise model of CBCT projection data can improve the performance of the statistics-based projection restoration algorithm for low-dose CBCT.« less

  17. Harm reduction and law enforcement in Vietnam: influences on street policing

    PubMed Central

    2012-01-01

    Background and rationale The HIV epidemic in Vietnam has from its start been concentrated among injecting drug users. Vietnam instituted the 2006 HIV/AIDS Law which includes comprehensive harm reduction measures, but these are unevenly accepted and inadequately implemented. Ward police are a major determinant of risk for IDUs, required to participate in drug control practices (especially meeting quotas for detention centres) which impede support for harm reduction. We studied influences on ward level police regarding harm reduction in Hanoi to learn how to better target education and structural change. Methods After document review, we interviewed informants from government, NGOs, INGOs, multilateral agencies, and police, using semi-structured guides. Topics covered included perceptions of harm reduction and the police role in drug law enforcement, and harm reduction training and advocacy among police. Results Police perceive conflicting responsibilities, but overwhelmingly see their responsibility as enforcing drug laws, identifying and knowing drug users, and selecting those for compulsory detention. Harm reduction training was very patchy, ward police not being seen as important to it; and understanding of harm reduction was limited, tending to reflect drug control priorities. Justification for methadone was as much crime prevention as HIV prevention. Competing pressures on ward police create much anxiety, with performance measures based around drug control; recourse to detention resolves competing pressures more safely. There is much recognition of the importance of discretion, and much use of it to maintain good social order. Policy dissemination approaches within the law enforcement sector were inconsistent, with little communication about harm reduction programs or approaches, and an unfounded assumption that training at senior levels would naturally reach to the street. Discussion Ward police have not been systematically included in harm reduction advocacy or training strategies to support or operationalise legalised harm reduction interventions. The practices of street police challenge harm reduction policies, entirely understandably given the competing pressures on them. For harm reduction to be effective in Vietnam, it is essential that the ambiguities and contradictions between laws to control HIV and to control drugs be resolved for the street-level police. PMID:22769590

  18. The effectiveness of measures to reduce the man-made greenhouse effect. The application of a Climate-policy Model

    NASA Astrophysics Data System (ADS)

    Jain, A. K.; Bach, W.

    1994-06-01

    In this paper we briefly describe the characteristics and the performance of our 1-D Muenster Climate Model. The model system consists of coupled models including gas cycle models, an energy balance model and a sea level rise model. The chemical feedback mechanisms among greenhouse gases are not included. This model, which is a scientifically-based parameterized simulation model, is used here primarily to help assess the effectiveness of various plausible policy options in mitigating the additional man-made greenhouse warming and the resulting sea level rise. For setting priorities it is important to assess the effectiveness of the various measures by which the greenhouse effect can be reduced. To this end we take a Scenario Business-as-Usual as a reference case (Leggett et al., 1992) and study the mitigating effects of the following four packages of measures: The Copenhagen Agreements on CFC, HCFC, and halon reduction (GECR, 1992), the Tropical Forest Preservation Plan of the Climate Enquete-Commission of the German Parliament on CO2 reduction (ECGP, 1990), a detailed reduction scheme for energy-related CO2 (ECGP, 1990), and a preliminary scheme for CH4, CO, and N2O reduction (Bach and Jain, 1992 1993). The required reduction depends, among others, on the desired climate and ecosystem protection. This is defined by the Enquete-Commission and others as a mean global rate of surface temperature change of ca. 0.1 °C per decade — assumed to be critical to many ecosystems — and a mean global warming ceiling of ca. 2 °C in 2100 relative to 1860. Our results show that the Copenhagen Agreements, the Tropical Forest Preservation Plan, the energy-related CO2 reduction scheme, and the CH4 and N2O reduction schemes could mitigate the anthropogenic greenhouse warming by ca. 12%, 6%, 35%, and 9% respectively. Taken together, all four packages of measures could reduce the man-made greenhouse effect by more than 60% until 2100; i.e. over the climate sensitivity range 2.5 °C (1.5 to 4.5) for 2 × CO2, the warming could be reduced from 3.5 °C (2.4 to 5.0) without specific measures to 1.3 °C (0.9 to 2.0) with the above packages of measures; and likewise, the mean global sea level rise could be reduced from 65 cm (46 to 88) without specific measures to 32 cm (22 to 47) with the above measures. Finally, the model results also emphasize the importance of trace gases other than CO2 in mitigating additional man-made greenhouse warming. According to our preliminary estimates, CH4 could in the short term make a sizable contribution to the reduction of the greenhouse effect (because of its relatively short lifetime of 10 yr), as could N2O in the medium and long term (with a relatively long lifetime of 150 yr).

  19. Noise reduction improves memory for target language speech in competing native but not foreign language speech.

    PubMed

    Ng, Elaine Hoi Ning; Rudner, Mary; Lunner, Thomas; Rönnberg, Jerker

    2015-01-01

    A hearing aid noise reduction (NR) algorithm reduces the adverse effect of competing speech on memory for target speech for individuals with hearing impairment with high working memory capacity. In the present study, we investigated whether the positive effect of NR could be extended to individuals with low working memory capacity, as well as how NR influences recall performance for target native speech when the masker language is non-native. A sentence-final word identification and recall (SWIR) test was administered to 26 experienced hearing aid users. In this test, target spoken native language (Swedish) sentence lists were presented in competing native (Swedish) or foreign (Cantonese) speech with or without binary masking NR algorithm. After each sentence list, free recall of sentence final words was prompted. Working memory capacity was measured using a reading span (RS) test. Recall performance was associated with RS. However, the benefit obtained from NR was not associated with RS. Recall performance was more disrupted by native than foreign speech babble and NR improved recall performance in native but not foreign competing speech. Noise reduction improved memory for speech heard in competing speech for hearing aid users. Memory for native speech was more disrupted by native babble than foreign babble, but the disruptive effect of native speech babble was reduced to that of foreign babble when there was NR.

  20. The impact of pediatric neuropsychological consultation in mild traumatic brain injury: a model for providing feedback after invalid performance.

    PubMed

    Connery, Amy K; Peterson, Robin L; Baker, David A; Kirkwood, Michael W

    2016-05-01

    In recent years, pediatric practitioners have increasingly recognized the importance of objectively measuring performance validity during clinical assessments. Yet, no studies have examined the impact of neuropsychological consultation when invalid performance has been identified in pediatric populations and little published guidance exists for clinical management. Here we provide a conceptual model for providing feedback after noncredible performance has been detected. In a pilot study, we examine caregiver satisfaction and postconcussive symptoms following provision of this feedback for patients seen through our concussion program. Participants (N = 70) were 8-17-year-olds with a history of mild traumatic brain injury who underwent an abbreviated neuropsychological evaluation between 2 and 12 months post-injury. We examined postconcussive symptom reduction and caregiver satisfaction after neuropsychological evaluation between groups of patients who were determined to have provided noncredible effort (n = 9) and those for whom no validity concerns were present (n = 61). We found similarly high levels of caregiver satisfaction between groups and greater reduction in self-reported symptoms after feedback was provided using the model with children with noncredible presentations compared to those with credible presentations. The current study lends preliminary support to the idea that the identification and communication of invalid performance can be a beneficial clinical intervention that promotes high levels of caregiver satisfaction and a reduction in self-reported and caregiver-reported symptoms.

  1. Performances of Kevlar and Polyethylene as radiation shielding on-board the International Space Station in high latitude radiation environment.

    PubMed

    Narici, Livio; Casolino, Marco; Di Fino, Luca; Larosa, Marianna; Picozza, Piergiorgio; Rizzo, Alessandro; Zaconte, Veronica

    2017-05-10

    Passive radiation shielding is a mandatory element in the design of an integrated solution to mitigate the effects of radiation during long deep space voyages for human exploration. Understanding and exploiting the characteristics of materials suitable for radiation shielding in space flights is, therefore, of primary importance. We present here the results of the first space-test on Kevlar and Polyethylene radiation shielding capabilities including direct measurements of the background baseline (no shield). Measurements are performed on-board of the International Space Station (Columbus modulus) during the ALTEA-shield ESA sponsored program. For the first time the shielding capability of such materials has been tested in a radiation environment similar to the deep-space one, thanks to the feature of the ALTEA system, which allows to select only high latitude orbital tracts of the International Space Station. Polyethylene is widely used for radiation shielding in space and therefore it is an excellent benchmark material to be used in comparative investigations. In this work we show that Kevlar has radiation shielding performances comparable to the Polyethylene ones, reaching a dose rate reduction of 32 ± 2% and a dose equivalent rate reduction of 55 ± 4% (for a shield of 10 g/cm 2 ).

  2. Above room temperature operation of InGaAs/AlGaAs/GaAs quantum cascade lasers

    NASA Astrophysics Data System (ADS)

    Pierścińska, D.; Gutowski, P.; Hałdaś, G.; Kolek, A.; Sankowska, I.; Grzonka, J.; Mizera, J.; Pierściński, K.; Bugajski, M.

    2018-03-01

    In this work we report on the performance of mid-infrared quantum cascade lasers (QCLs) based on strained InGaAs/AlGaAs grown by molecular beam epitaxy on GaAs substrate. Structures were grown with indium content from 1% to 6% in GaAs quantum wells (QW) and 45% of Al in AlGaAs barrier layers. The design results in strained heterostructure, however, no strain relaxation was observed as documented by x-ray diffraction measurements up to ∼3% of In content in QWs. The investigation of heterostructures and devices was performed, including structural measurements and electrooptical characterization of devices. Devices fabricated from epi wafers with 2.64% of In exhibited performance largely improved over GaAs/AlGaAs QCLs. Roughly two times reduction of the threshold current density was observed at lasing wavelength ∼9.45 μm. The lasers operated in pulsed mode up to T = 50 °C with characteristic temperature T 0 = 115 K. The decrease of the threshold current density has been mainly attributed to the reduction of interface roughness scattering and the increase of activation energy for the escape of carriers from the upper laser level to the 3D continuum. Further increase of In content in QWs resulted in the deterioration of device parameters.

  3. Quality improvement in childhood obesity management through the maintenance of certification process.

    PubMed

    Huang, Jeannie S; Chun, Stanford; Sandhu, Amanpreet; Terrones, Laura

    2013-11-01

    To assess the Health and Obesity: Prevention and Education (HOPE) Curriculum Project, a web-based clinician education program that promotes appropriate screening, prevention, and management of weight among youth by pediatric practitioners, based on the 2007 Expert Committee recommendations. The project currently provides Maintenance of Certification (MOC) Part 4 credit through the American Board of Pediatrics. Participants identified themselves to the HOPE MOC Part 4 program. Enrollees were required to complete all continuing medical education modules (10.5 hours). Knowledge acquisition and self-reported confidence levels related to screening, prevention, and management practices of pediatric obesity were measured using preknowledge and postknowledge questionnaires. Participants were also required to perform a quality improvement project and submit practice performance data from repeated medical chart reviews over time. Knowledge acquisition, self-efficacy, and practice performance data were analyzed using repeated-measures analyses. The 51 participants demonstrated significant improvements in knowledge acquisition and self-efficacy scores after viewing individual modules. In addition, participants demonstrated significant improvements in measured clinical compliance with recommended practices over time. Participation in the HOPE MOC Part 4 program appeared to improve knowledge acquisition, self-efficacy, and physician compliance with recommended practice recommendations for the screening, prevention, and management of pediatric obesity. Further data are required to determine whether such practice-based improvements translate into actual reduction in patient weight and/or reduction in health-related costs related to overweight and obesity in youth. Copyright © 2013 Mosby, Inc. All rights reserved.

  4. Feedback on Measured Dust Concentrations Reduces Exposure Levels Among Farmers.

    PubMed

    Basinas, Ioannis; Sigsgaard, Torben; Bønløkke, Jakob Hjort; Andersen, Nils Testrup; Omland, Øyvind; Kromhout, Hans; Schlünssen, Vivi

    2016-08-01

    The high burden of exposure to organic dust among livestock farmers warrants the establishment of effective preventive and exposure control strategies for these workers. The number of intervention studies exploring the effectiveness of exposure reduction strategies through the use of objective measurements has been limited. To examine whether dust exposure can be reduced by providing feedback to the farmers concerning measurements of the exposure to dust in their farm. The personal dust levels of farmers in 54 pig and 26 dairy cattle farms were evaluated in two measurement series performed approximately 6 months apart. Detailed information on work tasks and farm characteristics during the measurements were registered. Participating farms were randomized a priori to a control (n = 40) and an intervention group (n = 40). Shortly after the first visit, owners of intervention farms only received a letter with information on the measured dust concentrations in the farm together with some general advises on exposure reduction strategies (e.g. use of respirators during certain tasks). Relationships between measured dust concentrations and intervention status were quantified by means of linear mixed effect analysis with farm and worker id as random effects. Season, type of farming, and work tasks were treated as fixed effects. Changes in exposure over time were explored primarily at a farm level in models combined, as well as separate for pig and cattle farmers. After adjustment for fixed effects, an overall reduction of 23% in personal dust exposures was estimated as a result of the intervention (P = 0.02). Exposure reductions attributable to the intervention were similar across pig and cattle farmers, but statistically significant only for pig farmers. Intervention effects among pig farmers did not depend on the individuals' information status; but among cattle farmers a significant 48% reduction in exposure was found only among individuals that reported to have been informed. No systematic differences in changes over time considering the use of respiratory protection between the intervention and control groups were observed. The results of the present study suggest reductions between 20 and 30% in personal exposure to inhalable dust to be feasible through simple information provided to the farm owners regarding actual levels of exposure together with instructions on basic measures of prevention. The exact reasons for these effects are unclear, but likely they involve changes in behavior and working practices among intervention farmers. © The Author 2016. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  5. Three Averaging Techniques for Reduction of Antenna Temperature Variance Measured by a Dicke Mode, C-Band Radiometer

    NASA Technical Reports Server (NTRS)

    Mackenzie, Anne I.; Lawrence, Roland W.

    2000-01-01

    As new radiometer technologies provide the possibility of greatly improved spatial resolution, their performance must also be evaluated in terms of expected sensitivity and absolute accuracy. As aperture size increases, the sensitivity of a Dicke mode radiometer can be maintained or improved by application of any or all of three digital averaging techniques: antenna data averaging with a greater than 50% antenna duty cycle, reference data averaging, and gain averaging. An experimental, noise-injection, benchtop radiometer at C-band showed a 68.5% reduction in Delta-T after all three averaging methods had been applied simultaneously. For any one antenna integration time, the optimum 34.8% reduction in Delta-T was realized by using an 83.3% antenna/reference duty cycle.

  6. Achieving Very High Efficiency and Net Zero Energy in an Existing Home in a Hot-Humid Climate: Long-Term Utility and Monitoring Data (Revised)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parker, D.; Sherwin, J.

    2012-10-01

    This study summarizes the first six months of detailed data collected on a single family home that experienced a series of retrofits targeting reductions in energy use. The project was designed to develop data on how envelope modifications and renewable measures can result in considerable energy reductions and potentially net zero energy for an existing home. Originally published in February 2012, this revised version of the report contains further research conducted on the Parker residence. Key updates include one full year of additional data, an analysis of cooling performance of the mini-split heat pump, an evaluation of room-to-room temperature distribution,more » and an evaluation of plug-in automobile charging performance, electricity consumption, and load shape.« less

  7. Achieving Very High Efficiency and Net Zero Energy in an Existing Home in a Hot-Humid Climate. Long-Term Utility and Monitoring Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parker, D.; Sherwin, J.

    2012-10-01

    This study summarizes the first six months of detailed data collected on a single family home that experienced a series of retrofits targeting reductions in energy use. The project was designed to develop data on how envelope modifications and renewable measures can result in considerable energy reductions and potentially net zero energy for an existing home. Originally published in February 2012, this revised version of the report contains further research conducted on the Parker residence. Key updates include one full year of additional data, an analysis of cooling performance of the mini-split heat pump, an evaluation of room-to-room temperature distribution,more » and an evaluation of plug-in automobile charging performance, electricity consumption, and load shape.« less

  8. CFD Analysis in Advance of the NASA Juncture Flow Experiment

    NASA Technical Reports Server (NTRS)

    Lee, H. C.; Pulliam, T. H.; Neuhart, D. H.; Kegerise, M. A.

    2017-01-01

    NASA through its Transformational Tools and Technologies Project (TTT) under the Advanced Air Vehicle Program, is supporting a substantial effort to investigate the formation and origin of separation bubbles found on wing-body juncture zones. The flow behavior in these regions is highly complex, difficult to measure experimentally, and challenging to model numerically. Multiple wing configurations were designed and evaluated using Computational Fluid Dynamics (CFD), and a series of wind tunnel risk reduction tests were performed to further down-select the candidates for the final experiment. This paper documents the CFD analysis done in conjunction with the 6 percent scale risk reduction experiment performed in NASA Langley's 14- by 22-Foot Subsonic Tunnel. The combined CFD and wind tunnel results ultimately helped the Juncture Flow committee select the wing configurations for the final experiment.

  9. Experimental assessment of the performance of ablative heat shield materials from plasma wind tunnel testing

    NASA Astrophysics Data System (ADS)

    Löhle, S.; Hermann, T.; Zander, F.

    2018-06-01

    A method for assessing the performance of typical heat shield materials is presented in this paper. Three different material samples, the DLR material Zuram, the Airbus material Asterm and the carbon preform Calcarb were tested in the IRS plasma wind tunnel PWK1 at the same nominal condition. State of the art diagnostic tools, i.e., surface temperature with pyrometry and thermography and boundary layer optical emission spectroscopy were completed by photogrammetric surface recession measurements. These data allow the assessment of the net heat flux for each material. The analysis shows that the three materials each have a different effect on heat flux mitigation with ASTERM showing the largest reduction in surface heat flux. The effect of pyrolysis and blowing is clearly observed and the heat flux reduction can be determined from an energy balance.

  10. Verbal and Nonverbal Neuropsychological Test Performance in Subjects With Schizotypal Personality Disorder

    PubMed Central

    Voglmaier, Martina M.; Seidman, Larry J.; Niznikiewicz, Margaret A.; Dickey, Chandlee C.; Shenton, Martha E.; McCarley, Robert W.

    2010-01-01

    Objective The authors contrasted verbal and nonverbal measures of attention and memory in patients with DSM-IV-defined schizotypal personality disorder in order to expand on their previous findings of verbal learning deficits in these patients and to understand better the neuropsychological profile of schizotypal personality disorder. Method Cognitive test performance was examined in 16 right-handed men who met diagnostic criteria for schizotypal personality disorder and 16 matched male comparison subjects. Neuropsychological measures included verbal and nonverbal tests of persistence, supraspan learning, and short- and long-term memory retention. Neuropsychological profiles were constructed by standardizing test scores based on the means and standard deviations of the comparison subject group. Results Subjects with schizotypal personality disorder showed a mild to moderate general reduction in performance on all measures. Verbal measures of persistence, short-term retention, and learning were more severely impaired than their nonverbal analogs. Performance on measures of memory retention was independent of modality. Conclusions The results are consistent with previous reports that have suggested a mild, general decrement in cognitive performance and proportionately greater involvement of the left hemisphere in patients with schizotypal personality disorder. The findings provide further support for a specific deficit in the early processing stages of verbal learning. PMID:10784473

  11. Highly concentrated, stable nitrogen-doped graphene for supercapacitors: Simultaneous doping and reduction

    NASA Astrophysics Data System (ADS)

    Jiang, Baojiang; Tian, Chungui; Wang, Lei; Sun, Li; Chen, Chen; Nong, Xiaozhen; Qiao, Yingjie; Fu, Honggang

    2012-02-01

    In this work, we developed a concentrated ammonia-assisted hydrothermal method to obtain N-doped graphene sheets by simultaneous N-doping and reduction of graphene oxide (GO) sheets. The effects of hydrothermal temperature on the surface chemistry and the structure of N-doped graphene sheets were also investigated. X-ray photoelectron spectroscopy (XPS) study of N-doped graphene reveals that the highest doping level of 7.2% N is achieved at 180 °C for 12 h. N binding configurations of sample consist of pyridine N, quaternary N, and pyridine-N oxides. N doping is accompanied by the reduction of GO with decreases in oxygen levels from 34.8% in GO down to 8.5% in that of N-doped graphene. Meanwhile, the sample exhibits excellent N-doped thermal stability. Electrical measurements demonstrate that products have higher capacitive performance than that of pure graphene, the maximum specific capacitance of 144.6 F/g can be obtained which ascribe the pseudocapacitive effect from the N-doping. The samples also show excellent long-term cycle stability of capacitive performance.

  12. Mass reduction patterning of silicon-on-oxide-based micromirrors

    NASA Astrophysics Data System (ADS)

    Hall, Harris J.; Green, Andrew; Dooley, Sarah; Schmidt, Jason D.; Starman, LaVern A.; Langley, Derrick; Coutu, Ronald A.

    2016-10-01

    It has long been recognized in the design of micromirror-based optical systems that balancing static flatness of the mirror surface through structural design with the system's mechanical dynamic response is challenging. Although a variety of mass reduction approaches have been presented in the literature to address this performance trade, there has been little quantifiable comparison reported. In this work, different mass reduction approaches, some unique to the work, are quantifiably compared with solid plate thinning in both curvature and mass using commercial finite element simulation of a specific square silicon-on-insulator-based micromirror geometry. Other important considerations for micromirror surfaces, including surface profile and smoothness, are also discussed. Fabrication of one of these geometries, a two-dimensional tessellated square pattern, was performed in the presence of a 400-μm-tall central post structure using a simple single mask process. Limited experimental curvature measurements of fabricated samples are shown to correspond well with properly characterized simulation results and indicate ˜67% improvement in radius of curvature in comparison to a solid plate design of equivalent mass.

  13. Spectral Performance of a Composite Single-Crystal Filtered Thermal Neutron Beam for BNCT Research at the University of Missouri

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J. Brockman; D. W. Nigg; M. F. Hawthorne

    2009-07-01

    Parameter studies, design calculations and initial neutronic performance measurements have been completed for a new thermal neutron beamline to be used for neutron capture therapy cell and small-animal radiobiology studies at the University of Missouri Research Reactor. The beamline features the use of single-crystal silicon and bismuth sections for neutron filtering and for reduction of incident gamma radiation. The calculated and measured thermal neutron fluxes produced at the irradiation location are 9.6x108 and 8.8x108 neutrons/cm2-s, respectively. Calculated and measured cadmium ratios (Au foils) are 217 and 132. These results indicate a well-thermalized neutron spectrum with sufficient thermal neutron flux formore » a variety of small animal BNCT studies.« less

  14. Advanced Metering Implementations - A Perspective from Federal Sector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eaarni, Shankar

    2014-08-11

    Federal mandate (EPACT 2005) requires that federal buildings install advanced electrical meters-meters capable of providing data at least daily and measuring the consumption of electricity at least hourly. This work presents selected advanced metering implementations to understand some of the existing practices related to data capture and to understand how the data is being translated into information and knowledge that can be used to improve building energy and operational performance to meet federal energy reduction mandates. This study highlights case studies to represent some of the various actions that are being taken based on the data that are being collectedmore » to improve overall energy performance of these buildings. Some of these actions include- individualized tenant billing and energy forecasting, benchmarking, identifying energy conservation measures, measurement and verification.« less

  15. [Effects of a programme of aquatic Ai Chi exercise in patients with fibromyalgia. A pilot study].

    PubMed

    Perez-De la Cruz, Sagrario; Lambeck, Johan

    2015-01-16

    Fibromyalgia is rheumathological disease a combination of physical, psychological and social limitations. The aim of the present study is to determinate the benefits of Ai Chi program on quality of life, depression and pain. An experimental study was performed with 20 fibromyalgia patients two different cities. Outcome measures were functional capacity (Fibromyalgia Impact Questionnaire), pain (Visual Analogue Scale) and quality of life (Short Form-36). Measures were performed at baseline and after ten weeks post-intervention. After ten weeks of treatment, the results showed significant reduction (p < 0,05) in virtually all outcome measures. An Ai Chi aquatic therapy programme contributes to reduce pain and improve quality of life as well as physical and mental health in patients with fibromyalgia.

  16. Rate Dependency of Silver Vanadium Phosphorous Oxide Reduction

    NASA Astrophysics Data System (ADS)

    Cheng, Po-Jen

    2011-12-01

    The silver vanadium phosphorus oxide (Ag2VO2PO 4) is a high-capacity and good-compatibility material for the cathode in the battery. Due to their innovative properties, they are used as cathode in lithium batteries. Therefore, when the lithium batteries begin to discharge, the anodes of the cell perform an electrochemical oxidation and release electrons. In the mean time, the cathodes in the cells perform the electrochemical reduction and catch the electrons. For reduction of Ag2VO2PO 4, two silver ions (Ag+) catch two electrons to form silver particles, and the vanadium ions (V5+) catch two electrons to form V3+. It means that four electrons will be released by lithium anode. We call this four electrons discharge as 100% discharge. In my most of the projects, the Ag2VO2PO4 material is tested by differential scanning calorimetry (DSC) to check purity. My study is based on the discharge of batteries, and I focus on the morphology and the intensity of silver particles on the cathode after discharge. Depending on different adjustment of factors, such as discharge time, discharge rate, storage time, storage temperature, I try to investigate the silver intensity, conductivity as a function of DOD (Depth of Discharge). The silver particles could be examined by optical microscope, and scanning electron microscope (SEM). Moreover, I do some x-ray diffraction analysis to quantify the silver particles after discharge. Also, I perform magnetic susceptibility measurement to check the mechanism of the reduction of vanadium ions. Under the research on silver ions and vanadium ions, I will know a big frame of reduction process on silver vanadium phosphorous oxide and the time effect on this cathode material.

  17. The Second Stroke Audit of Catalonia shows improvements in many, but not all quality indicators.

    PubMed

    Abilleira, Sònia; Ribera, Aida; Sánchez, Emília; Tresserras, Ricard; Gallofré, Miquel

    2012-01-01

    Periodic audits allow monitoring of healthcare quality by comparing performances at different time points. Aims To assess quality of in-hospital stroke care in Catalonia in 2007 and compare it with 2005 (post-/preguidelines delivery, respectively). Data on 13 evidence-based performance measures were collected by a retrospective review of medical records of consecutive stroke admissions (January-December 2007) to 47 acute hospitals in Catalonia. Adherence was calculated according to the ratio (patients with documented performance measures' compliance) (valid cases for that measure). Sampling weights were applied to produce estimates of compliance. The proportions of compliance with performance measures in both audits were compared using random-effects logistic regressions, with each performance measure as the dependent variable and audit edition as the explanatory variable to determine whether changes in stroke care quality occurred along time. We analyzed 1767 events distributed among 47 hospitals. In 2007, there was an increase in tissue plasminogen activator administrations (2·8% vs. 5·9%) and stroke unit admissions (16·6% vs. 22·6%) and a reduction in seven-day mortality (9·5% vs. 6·8%). Logistic regression models provided evidence of improved adherences to seven performance measures (screening of dysphagia, management of hyperthermia, baseline computed tomography scan, baseline glycemia, rehabilitation needs, early mobilization, and anticoagulants for atrial fibrillation), but worsening of management of hypertension, dyslipidemia, and antithrombotics at discharge. The remaining three performance measures showed no changes. The Second Stroke Audit showed improvements in most dimensions of care, although unexpectedly a few but relevant performance measures became worse. Therefore, periodic stroke audits are needed to check changes in quality of care over time. © 2011 The Authors. International Journal of Stroke © 2011 World Stroke Organization.

  18. Reliability of Measurements Performed by Community-Drawn Anthropometrists from Rural Ethiopia

    PubMed Central

    Ayele, Berhan; Aemere, Abaineh; Gebre, Teshome; Tadesse, Zerihun; Stoller, Nicole E.; See, Craig W.; Yu, Sun N.; Gaynor, Bruce D.; McCulloch, Charles E.; Porco, Travis C.; Emerson, Paul M.; Lietman, Thomas M.; Keenan, Jeremy D.

    2012-01-01

    Background Undernutrition is an important risk factor for childhood mortality, and remains a major problem facing many developing countries. Millennium Development Goal 1 calls for a reduction in underweight children, implemented through a variety of interventions. To adequately judge the impact of these interventions, it is important to know the reproducibility of the main indicators for undernutrition. In this study, we trained individuals from rural communities in Ethiopia in anthropometry techniques and measured intra- and inter-observer reliability. Methods and Findings We trained 6 individuals without prior anthropometry experience to perform weight, height, and middle upper arm circumference (MUAC) measurements. Two anthropometry teams were dispatched to 18 communities in rural Ethiopia and measurements performed on all consenting pre-school children. Anthropometry teams performed a second independent measurement on a convenience sample of children in order to assess intra-anthropometrist reliability. Both teams measured the same children in 2 villages to assess inter-anthropometrist reliability. We calculated several metrics of measurement reproducibility, including the technical error of measurement (TEM) and relative TEM. In total, anthropometry teams performed measurements on 606 pre-school children, 84 of which had repeat measurements performed by the same team, and 89 of which had measurements performed by both teams. Intra-anthropometrist TEM (and relative TEM) were 0.35 cm (0.35%) for height, 0.05 kg (0.39%) for weight, and 0.18 cm (1.27%) for MUAC. Corresponding values for inter-anthropometrist reliability were 0.67 cm (0.75%) for height, 0.09 kg (0.79%) for weight, and 0.22 kg (1.53%) for MUAC. Inter-anthropometrist measurement error was greater for smaller children than for larger children. Conclusion Measurements of height and weight were more reproducible than measurements of MUAC and measurements of larger children were more reliable than those for smaller children. Community-drawn anthropometrists can provide reliable measurements that could be used to assess the impact of interventions for childhood undernutrition. PMID:22291939

  19. Boxfish swimming paradox resolved: forces by the flow of water around the body promote manoeuvrability

    PubMed Central

    Van Wassenbergh, S.; van Manen, K.; Marcroft, T. A.; Alfaro, M. E.; Stamhuis, E. J.

    2015-01-01

    The shape of the carapace protecting the body of boxfishes has been attributed an important hydrodynamic role in drag reduction and in providing automatic, flow-direction realignment and is therefore used in bioinspired design of cars. However, tight swimming-course stabilization is paradoxical given the frequent, high-performance manoeuvring that boxfishes display in their spatially complex, coral reef territories. Here, by performing flow-tank measurements of hydrodynamic drag and yaw moments together with computational fluid dynamics simulations, we reverse several assumptions about the hydrodynamic role of the boxfish carapace. Firstly, despite serving as a model system in aerodynamic design, drag-reduction performance was relatively low compared with more generalized fish morphologies. Secondly, the current theory of course stabilization owing to flow over the boxfish carapace was rejected, as destabilizing moments were found consistently. This solves the boxfish swimming paradox: destabilizing moments enhance manoeuvrability, which is in accordance with the ecological demands for efficient turning and tilting. PMID:25505133

  20. Evaluation of Shear Strength of RC Beams with Multiple Interfaces Formed before Initial Setting Using 3D Printing Technology

    PubMed Central

    Kim, Kyeongjin; Park, Sangmin; Jeong, Yoseok; Lee, Jaeha

    2017-01-01

    With the recent development of 3D printing technology, concrete materials are sometimes used in 3D printing. Concrete structures based on 3D printing have been characterized to have the form of multiple layer build-up. Unlike general concrete structures, therefore, the 3D-printed concrete can be regarded as an orthotropic material. The material property of the 3D-printed concrete’s interface between layers is expected to be far different from that of general concrete bodies since there are no aggregate interlocks and weak chemical bonding. Such a difference finally affects the structural performance of concrete structures even though the interfaces are formed before initial setting of the concrete. The current study mainly reviewed the changes in fracture energy (toughness) with respect to various environmental conditions of such interface. Changes in fracture energies of interfaces between concrete layers were measured using low-speed Crack Mouth Opening Displacement (CMOD) closed loop concrete fracture test. The experimental results indicated reduction in fracture energy as well as tensile strengths. To improve the tensile strength of interfaces, the use of bridging materials is suggested. Since it was assumed that reduction in fracture energy could be a cause of shear strength, to evaluate the reduced structural performance of concrete structure constructed with multiple interfaces by 3D printing technology, the shear strength of RC beam by 3D printing technology was predicted and compared with that of plain RC beam. Based on the fracture energy measured in this study, Modified Compression Field Theory (MCFT) theory-applied Vector 2 program was employed to predict the degree of reduction in shear strength without considering stirrups. Reduction factors were presented based on the obtained results to predict the reduction in shear strength due to interfaces before initial setting of the concrete.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Windisch, C.F. Jr.; Strachan, D.M.; Henager, C.H. Jr.

    Cermet anodes were evaluated as nonconsumable substitutes for carbon anodes using a pilot-scale reduction cell at the Reynolds Manufacturing Technology Laboratory. After pilot cell testing, tile anodes were subjected to extensive materials characterization and physical properties measurements at the Pacific Northwest Laboratory. Significant changes in the composition of the cermet anodes were observed including the growth of a reaction layer and penetration of electrolyte deep into the cermet matrix. Fracture strength and toughness were measured as a function of temperature and the ductile-brittle transition wasreduced by 500C following pilot cell testing. These results imply difficulties with anode material and controlmore » of operating conditions in the pilot cell, and suggest that additional development work be performed before the cermet anodes are used in commercial reduction cells. The results also highlight specific fabrication and operational considerations that should be addressed in future testing.« less

  2. Silicon materials task of the low cost solar array project, part 2

    NASA Technical Reports Server (NTRS)

    Hopkins, R. H.; Davis, J. R.; Rai-Choudhury, P.; Blais, P. D.; Mccormick, J. R.

    1976-01-01

    Purity requirements for solar cell grade silicon material was developed and defined by evaluating the effects of specific impurities and impurity levels on the performance of silicon solar cells. Also, data was generated forming the basis for cost-tradeoff analyses of silicon solar cell material. Growth, evaluation, solar cell fabrication and testing was completed for the baseline boron-doped Czochralski material. Measurements indicate Cn and Mn seriously degrade cell performance, while neither Ni nor Cu produce any serious reduction in cell efficiency.

  3. Baseline performance of solar collectors for NASA Langley solar building test facility

    NASA Technical Reports Server (NTRS)

    Knoll, R. H.; Johnson, S. M.

    1977-01-01

    The solar collector field contains seven collector designs. Before operation in the field, the experimental performances (thermal efficiencies) of the seven collector designs were measured in an indoor solar simulator. The resulting data provided a baseline for later comparison with actual field test data. The simulator test results are presented for the collectors as received, and after several weeks of outdoor exposure with no coolant (dry operation). Six of the seven collector designs tested showed substantial reductions in thermal efficiency after dry operation.

  4. Changes in depression mediate the effects of AA attendance on alcohol use outcomes.

    PubMed

    Wilcox, Claire E; Tonigan, J Scott

    2018-01-01

    Depression may contribute to increased drinking in individuals with alcohol use disorder. Although Alcoholics Anonymous (AA) attendance predicts drinking reductions, there is conflicting information regarding the intermediary role played by reductions in depression. We explored whether AA attendance reduces depressive symptoms, the degree to which improvement in depression results in reductions in drinking, and in which subgroups these effects occur. 253 early AA affiliates (63% male) were recruited and assessed at baseline 3, 6, 9, 12, 18, and 24 months. Depression was measured using the Beck Depression Inventory (BDI) and was administered at baseline 3, 6, 12, 18, and 24 months. AA attendance and alcohol use outcomes were obtained with the Form 90. Mediation analyses were performed at early (3, 6, and 9 months) and late (12, 18, and 24 months) follow-up to investigate the degree to which reductions in depression mediated the effect of AA attendance on drinking, controlling for concurrent drinking. In addition, a series of moderated mediation analyses were performed using baseline depression severity as a moderator. At early follow-up, reductions in depression (6 months) mediated the effects of AA attendance (3 months) on later drinking (drinks per drinking day) (9 months) (b = -0.02, boot CI [-0.055, -0.0004]), controlling for drinking at 6 months. Baseline depression severity did not moderate the degree to which BDI mediated the effects of AA attendance on alcohol use (ps > .05). These findings provide further evidence that depression reduction is a mechanism by which AA attendance leads to reductions in alcohol use. Improving depression may help reduce alcohol use in individuals with AUD, and AA attendance may be an effective way to achieve that goal.

  5. Optimizing value utilizing Toyota Kata methodology in a multidisciplinary clinic.

    PubMed

    Merguerian, Paul A; Grady, Richard; Waldhausen, John; Libby, Arlene; Murphy, Whitney; Melzer, Lilah; Avansino, Jeffrey

    2015-08-01

    Value in healthcare is measured in terms of patient outcomes achieved per dollar expended. Outcomes and cost must be measured at the patient level to optimize value. Multidisciplinary clinics have been shown to be effective in providing coordinated and comprehensive care with improved outcomes, yet tend to have higher cost than typical clinics. We sought to lower individual patient cost and optimize value in a pediatric multidisciplinary reconstructive pelvic medicine (RPM) clinic. The RPM clinic is a multidisciplinary clinic that takes care of patients with anomalies of the pelvic organs. The specialties involved include Urology, General Surgery, Gynecology, and Gastroenterology/Motility. From May 2012 to November 2014 we performed time-driven activity-based costing (TDABC) analysis by measuring provider time for each step in the patient flow. Using observed time and the estimated hourly cost of each of the providers we calculated the final cost at the individual patient level, targeting clinic preparation. We utilized Toyota Kata methodology to enhance operational efficiency in an effort to optimize value. Variables measured included cost, time to perform a task, number of patients seen in clinic, percent value-added time (VAT) to patients (face to face time) and family experience scores (FES). At the beginning of the study period, clinic costs were $619 per patient. We reduced conference time from 6 min/patient to 1 min per patient, physician preparation time from 8 min to 6 min and increased Medical Assistant (MA) preparation time from 9.5 min to 20 min, achieving a cost reduction of 41% to $366 per patient. Continued improvements further reduced the MA preparation time to 14 min and the MD preparation time to 5 min with a further cost reduction to $194 (69%) (Figure). During this study period, we increased the number of appointments per clinic. We demonstrated sustained improvement in FES with regards to the families overall experience with their providers. Value added time was increased from 60% to 78% but this was not significant. Time-based cost analysis effectively measures individualized patient cost. We achieved a 69% reduction in clinic preparation costs. Despite this reduction in costs, we were able to maintain VAT and sustain improvements in family experience. In caring for complex patients, lean management methodology enables optimization of value in a multidisciplinary clinic. Copyright © 2015. Published by Elsevier Ltd.

  6. Chamber-core structures for fairing acoustic mitigation

    NASA Astrophysics Data System (ADS)

    Ardelean, Emil; Williams, Andrew; Korshin, Nicholas; Henderson, Kyle; Lane, Steven; Richard, Robert

    2005-05-01

    Extreme noise and vibration levels at lift-off and during ascent can damage sensitive payload components. Recently, the Air Force Research Laboratory, Space Vehicles Directorate has investigated a composite structure fabrication approach, called chamber-core, for building payload fairings. Chamber-core offers a strong, lightweight structure with inherent noise attenuation characteristics. It uses one-inch square axial tubes that are sandwiched between inner and outer face-sheets to form a cylindrical fairing structure. These hollow tubes can be used as acoustic dampers to attenuate the amplitude response of low frequency acoustic resonances within the fairing"s volume. A cylindrical, graphite-epoxy chamber-core structure was built to study noise transmission characteristics and to quantify the achievable performance improvement. The cylinder was tested in a semi-reverberant acoustics laboratory using bandlimited random noise at sound pressure levels up to 110 dB. The performance was measured using external and internal microphones. The noise reduction was computed as the ratio of the spatially averaged external response to the spatially averaged interior response. The noise reduction provided by the chamber-core cylinder was measured over three bandwidths, 20 Hz to 500 Hz, 20 Hz to 2000 Hz, and 20 Hz to 5000 Hz. For the bare cylinder with no acoustic resonators, the structure provided approximately 13 dB of attenuation over the 20 Hz to 500 Hz bandwidth. With the axial tubes acting as acoustic resonators at various frequencies over the bandwidth, the noise reduction provided by the cylinder increased to 18.2 dB, an overall increase of 4.8 dB over the bandwidth. Narrow-band reductions greater than 10 dB were observed at specific low frequency acoustic resonances. This was accomplished with virtually no added mass to the composite cylinder.

  7. Nitrate reduction in a simulated free-water surface wetland system.

    PubMed

    Misiti, Teresa M; Hajaya, Malek G; Pavlostathis, Spyros G

    2011-11-01

    The feasibility of using a constructed wetland for treatment of nitrate-contaminated groundwater resulting from the land application of biosolids was investigated for a site in the southeastern United States. Biosolids degradation led to the release of ammonia, which upon oxidation resulted in nitrate concentrations in the upper aquifer in the range of 65-400 mg N/L. A laboratory-scale system was constructed in support of a pilot-scale project to investigate the effect of temperature, hydraulic retention time (HRT) and nitrate and carbon loading on denitrification using soil and groundwater from the biosolids application site. The maximum specific reduction rates (MSRR), measured in batch assays conducted with an open to the atmosphere reactor at four initial nitrate concentrations from 70 to 400 mg N/L, showed that the nitrate reduction rate was not affected by the initial nitrate concentration. The MSRR values at 22 °C for nitrate and nitrite were 1.2 ± 0.2 and 0.7 ± 0.1 mg N/mg VSS(COD)-day, respectively. MSRR values were also measured at 5, 10, 15 and 22 °C and the temperature coefficient for nitrate reduction was estimated at 1.13. Based on the performance of laboratory-scale continuous-flow reactors and model simulations, wetland performance can be maintained at high nitrogen removal efficiency (>90%) with an HRT of 3 days or higher and at temperature values as low as 5 °C, as long as there is sufficient biodegradable carbon available to achieve complete denitrification. The results of this study show that based on the climate in the southeastern United States, a constructed wetland can be used for the treatment of nitrate-contaminated groundwater to low, acceptable nitrate levels. Copyright © 2011 Elsevier Ltd. All rights reserved.

  8. Comparison of geometric morphometric outline methods in the discrimination of age-related differences in feather shape

    PubMed Central

    Sheets, H David; Covino, Kristen M; Panasiewicz, Joanna M; Morris, Sara R

    2006-01-01

    Background Geometric morphometric methods of capturing information about curves or outlines of organismal structures may be used in conjunction with canonical variates analysis (CVA) to assign specimens to groups or populations based on their shapes. This methodological paper examines approaches to optimizing the classification of specimens based on their outlines. This study examines the performance of four approaches to the mathematical representation of outlines and two different approaches to curve measurement as applied to a collection of feather outlines. A new approach to the dimension reduction necessary to carry out a CVA on this type of outline data with modest sample sizes is also presented, and its performance is compared to two other approaches to dimension reduction. Results Two semi-landmark-based methods, bending energy alignment and perpendicular projection, are shown to produce roughly equal rates of classification, as do elliptical Fourier methods and the extended eigenshape method of outline measurement. Rates of classification were not highly dependent on the number of points used to represent a curve or the manner in which those points were acquired. The new approach to dimensionality reduction, which utilizes a variable number of principal component (PC) axes, produced higher cross-validation assignment rates than either the standard approach of using a fixed number of PC axes or a partial least squares method. Conclusion Classification of specimens based on feather shape was not highly dependent of the details of the method used to capture shape information. The choice of dimensionality reduction approach was more of a factor, and the cross validation rate of assignment may be optimized using the variable number of PC axes method presented herein. PMID:16978414

  9. The assessment of engine losses due to friction and lubricant limitations. Final report May 80-Mar 81

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taylor, C.F.; Taylor, T. Jr; Kallin, R.L.

    A major area for improving the efficiency of spark ignition and diesel engines is a reduction of frictional losses. Existing literature on engine friction was used as a basis for estimating possible gains in engine fuel economy which look promising within the constraints of modern practice. The means considered include reduction in oil viscosity, increase in bearing and piston clearances, possible changes in piston and valve gear design, and reduction of pumping losses. Estimates indicate potential fuel consumption improvements of 3 to 4% for Otto-Cycle at wide open throttle, 7 to 9% for Otto-Cycle at road load, 4 to 5%more » for diesel at wide open throttle, and 6% for diesel at road-load. Much larger gains at road load could be obtained by using a stratified charge system which requires no air throttling. A literature search on techniques for measuring engine friction under firing conditions was also performed and various concepts employing Pressure-Volume Indicator Diagrams were assessed. Balanced pressure and direct pressure measurement in concert with instantaneous measurement of piston position provide the most reliable and repeatable assessment of engine efficiency. Pressure measurements in the range of 1/2 to 1% are achievable with digital processing techniques reducing dramatically the time and effort to generate P-V Indicator Diagrams.« less

  10. Microstructural analysis and thermoelectric properties of Sn-Al co-doped ZnO ceramics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoemke, Joshua, E-mail: jhoemke@sigma.t.u-tokyo.ac.jp; Tochigi, Eita; Shibata, Naoya

    2016-08-26

    Sn-Al co-doped polycrystalline ZnO ceramics were prepared by sintering in air. Phase and microstructure analysis was performed by X-ray diffraction and SEM-EDS and thermoelectric properties were measured. XRD analysis showed a ZnO primary phase as well as secondary phase peaks due to the formation of a Zn{sub 2}SnO{sub 4} spinel phase or SnO{sub 2}(ZnO:Sn-Al){sub m} intergrowth phase. SEM analysis revealed a dense microstructure with a small number of nanometric pores, consistent with the measured density of 5.48 g/cm{sup 3}. An activated electrical conductivity characteristic of a semiconducting material was observed as well as a negative Seebeck coefficient with both valuesmore » increasing in absolute value from RT to 730 °C. The power factor had a maximum value of 3.73×10{sup −4} W m{sup −1} K{sup −2} at 730 °C. Thermal conductivity measurements showed a significant reduction over the measured temperature range compared to undoped ZnO. This could be attributed to grain size reduction, the formation of a nanoscale secondary phase or a reduction in crystallinity caused by Sn-Al co-doping. A maximum ZT of 0.06 was obtained at 750 °C for the Sn-Al co-doped ZnO ceramics.« less

  11. Reducing fresh full term intrapartum stillbirths through leadership and accountability in a low-resource setting, Mpilo Central Hospital, Bulawayo, Zimbabwe.

    PubMed

    Ngwenya, Solwayo

    2017-07-06

    Stillbirths are distressing to the parents and healthcare workers. Globally large numbers of babies are stillborn. A number of strategies have been implemented to try and reduce stillbirths worldwide. The objective of this study was to assess the impact of leadership and accountability changes on reducing full term intrapartum stillbirths. Leadership and accountability changes were implemented in January 2016. This retrospective cohort study was carried out to assess the impact of the changes on fresh full term intrapartum stillbirths covering the period 6 months prior to the implementation date and 12 months after the implementation date. The changes included leadership and accountability. Fresh full term stillbirths (>37 weeks gestation) occurring during the intrapartum stage of labour were analysed to see if there would be any reduction in numbers after the measures were put in place. There was a reduction in the number of fresh full term intrapartum stillbirths after the introduction of the measures. There was a statistical difference before and after implementation of the changes, 50% vs 0%, P = 0.025. There was a reduction in the time it took to perform an emergency caesarean section from a mean of 30 to 15 min by the end of the study, a 50% reduction. Clear and consistent clinical leadership and accountability can help in the global attempts to reduce stillbirth figures. Simple measures can contribute to improving perinatal outcomes.

  12. Waste in the U.S. Health care system: a conceptual framework.

    PubMed

    Bentley, Tanya G K; Effros, Rachel M; Palar, Kartika; Keeler, Emmett B

    2008-12-01

    Health care costs in the United States are much higher than those in industrial countries with similar or better health system performance. Wasteful spending has many undesirable consequences that could be alleviated through waste reduction. This article proposes a conceptual framework to guide researchers and policymakers in evaluating waste, implementing waste-reduction strategies, and reducing the burden of unnecessary health care spending. This article divides health care waste into administrative, operational, and clinical waste and provides an overview of each. It explains how researchers have used both high-level and sector- or procedure-specific comparisons to quantify such waste, and it discusses examples and challenges in both waste measurement and waste reduction. Waste is caused by factors such as health insurance and medical uncertainties that encourage the production of inefficient and low-value services. Various efforts to reduce such waste have encountered challenges, such as the high costs of initial investment, unintended administrative complexities, and trade-offs among patients', payers', and providers' interests. While categorizing waste may help identify and measure general types and sources of waste, successful reduction strategies must integrate the administrative, operational, and clinical components of care, and proceed by identifying goals, changing systemic incentives, and making specific process improvements. Classifying, identifying, and measuring waste elucidate its causes, clarify systemic goals, and specify potential health care reforms that-by improving the market for health insurance and health care-will generate incentives for better efficiency and thus ultimately decrease waste in the U.S. health care system.

  13. In situ monitoring of atomic layer controlled pore reduction in alumina tubular membranes using sequential surface reactions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berland, B.S.; Gartland, I.P.; Ott, A.W.

    1998-12-01

    The pore diameter in alumina tubular membranes with an initial diameter of 50 {angstrom} was systematically reduced using the atomic layer controlled deposition of Al{sub 2}O{sub 3}. The Al{sub 2}O{sub 3} was deposited using sequential exposures of Al(CH{sub 3}){sub 3} (trimethylaluminum, TMA) and H{sub 2}O in an ABAB... binary reaction sequence. The pore diameter reduction was monitored using in situ N{sub 2} and Ar conductance measurements. The conductance, C = Q/{Delta}P, was measured using a mass flow controller to define a constant gas throughput, Q, and a pair of capacitance manometers to monitor the transmembrane pressure drop, {Delta}P. Conductance measurementsmore » were periodically obtained at 298 K as a function of AB binary reaction cycles. These conductance measurements were consistent with a pore diameter reduction from 50 {angstrom} to {approximately}5--10 {angstrom} at a rate of {approximately}2.5 {angstrom} for each AB cycle. Conductance measurements were also performed during the Al{sub 2}O{sub 3} deposition at 500 K after each half-reaction in the binary reaction sequence. These in situ conductance measurements demonstrate that the pore diameters in mesoporous membranes can be reduced to molecular dimensions with atomic layer control using sequential surface reactions. Poe diameters can be tailored for specific applications by varying the number of AB cycles and changing the nature of the terminating surface functional groups.« less

  14. Free-jet acoustic investigation of high-radius-ratio coannular plug nozzles

    NASA Technical Reports Server (NTRS)

    Knott, P. R.; Janardan, B. A.; Majjigi, R. K.; Bhutiani, P. K.; Vogt, P. G.

    1984-01-01

    The experimental and analytical results of a scale model simulated flight acoustic exploratory investigation of high radius ratio coannular plug nozzles with inverted velocity and temperature profiles are summarized. Six coannular plug nozzle configurations and a baseline convergent conical nozzle were tested for simulated flight acoustic evaluation. The nozzles were tested over a range of test conditions that are typical of a Variable Cycle Engine for application to advanced high speed aircraft. It was found that in simulate flight, the high radius ratio coannular plug nozzles maintain their jet noise and shock noise reduction features previously observed in static testing. The presence of nozzle bypass struts will not significantly affect the acousticn noise reduction features of a General Electric type nozzle design. A unique coannular plug nozzle flight acoustic spectral prediction method was identified and found to predict the measured results quite well. Special laser velocimeter and acoustic measurements were performed which have given new insights into the jet and shock noise reduction mechanisms of coannular plug nozzles with regard to identifying further benificial research efforts.

  15. Aerodynamic characteristics and heat radiation performance of sportswear fabrics

    NASA Astrophysics Data System (ADS)

    Koga, H.; Hiratsuka, M.; Ito, S.; Konno, A.

    2017-10-01

    Sports such as swimming, speed skating, and marathon are sports competing for time. In recent years, reduction of the fluid drag of sportswear is required for these competitions in order to improve the record. In addition, sweating and discomfort due to body temperature rise during competition are thought to affect competitor performance, and heat radiation performance is also an important factor for sportswear. The authors have measured fluid force drag by wrapping cloth around a cylinder and have confirmed their differences due to the roughness of the fabric surface, differences in sewing. The authors could be verified the drag can be reduced by the position of the wear stitch. This time, we measured the heat radiation performance of 14 types of cloths whose aero dynamic properties are known using cylinders which are regarded as human fuselages, and found elements of cloth with heat radiation performance. It was found to be important for raising the heat radiation performance of sportswear that the fabric is thin and flat surface processing.

  16. SU-C-207B-02: Maximal Noise Reduction Filter with Anatomical Structures Preservation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maitree, R; Guzman, G; Chundury, A

    Purpose: All medical images contain noise, which can result in an undesirable appearance and can reduce the visibility of anatomical details. There are varieties of techniques utilized to reduce noise such as increasing the image acquisition time and using post-processing noise reduction algorithms. However, these techniques are increasing the imaging time and cost or reducing tissue contrast and effective spatial resolution which are useful diagnosis information. The three main focuses in this study are: 1) to develop a novel approach that can adaptively and maximally reduce noise while preserving valuable details of anatomical structures, 2) to evaluate the effectiveness ofmore » available noise reduction algorithms in comparison to the proposed algorithm, and 3) to demonstrate that the proposed noise reduction approach can be used clinically. Methods: To achieve a maximal noise reduction without destroying the anatomical details, the proposed approach automatically estimated the local image noise strength levels and detected the anatomical structures, i.e. tissue boundaries. Such information was used to adaptively adjust strength of the noise reduction filter. The proposed algorithm was tested on 34 repeating swine head datasets and 54 patients MRI and CT images. The performance was quantitatively evaluated by image quality metrics and manually validated for clinical usages by two radiation oncologists and one radiologist. Results: Qualitative measurements on repeated swine head images demonstrated that the proposed algorithm efficiently removed noise while preserving the structures and tissues boundaries. In comparisons, the proposed algorithm obtained competitive noise reduction performance and outperformed other filters in preserving anatomical structures. Assessments from the manual validation indicate that the proposed noise reduction algorithm is quite adequate for some clinical usages. Conclusion: According to both clinical evaluation (human expert ranking) and qualitative assessment, the proposed approach has superior noise reduction and anatomical structures preservation capabilities over existing noise removal methods. Senior Author Dr. Deshan Yang received research funding form ViewRay and Varian.« less

  17. An adaptive algorithm for the detection of microcalcifications in simulated low-dose mammography.

    PubMed

    Treiber, O; Wanninger, F; Führ, H; Panzer, W; Regulla, D; Winkler, G

    2003-02-21

    This paper uses the task of microcalcification detection as a benchmark problem to assess the potential for dose reduction in x-ray mammography. We present the results of a newly developed algorithm for detection of microcalcifications as a case study for a typical commercial film-screen system (Kodak Min-R 2000/2190). The first part of the paper deals with the simulation of dose reduction for film-screen mammography based on a physical model of the imaging process. Use of a more sensitive film-screen system is expected to result in additional smoothing of the image. We introduce two different models of that behaviour, called moderate and strong smoothing. We then present an adaptive, model-based microcalcification detection algorithm. Comparing detection results with ground-truth images obtained under the supervision of an expert radiologist allows us to establish the soundness of the detection algorithm. We measure the performance on the dose-reduced images in order to assess the loss of information due to dose reduction. It turns out that the smoothing behaviour has a strong influence on detection rates. For moderate smoothing. a dose reduction by 25% has no serious influence on the detection results. whereas a dose reduction by 50% already entails a marked deterioration of the performance. Strong smoothing generally leads to an unacceptable loss of image quality. The test results emphasize the impact of the more sensitive film-screen system and its characteristics on the problem of assessing the potential for dose reduction in film-screen mammography. The general approach presented in the paper can be adapted to fully digital mammography.

  18. An adaptive algorithm for the detection of microcalcifications in simulated low-dose mammography

    NASA Astrophysics Data System (ADS)

    Treiber, O.; Wanninger, F.; Führ, H.; Panzer, W.; Regulla, D.; Winkler, G.

    2003-02-01

    This paper uses the task of microcalcification detection as a benchmark problem to assess the potential for dose reduction in x-ray mammography. We present the results of a newly developed algorithm for detection of microcalcifications as a case study for a typical commercial film-screen system (Kodak Min-R 2000/2190). The first part of the paper deals with the simulation of dose reduction for film-screen mammography based on a physical model of the imaging process. Use of a more sensitive film-screen system is expected to result in additional smoothing of the image. We introduce two different models of that behaviour, called moderate and strong smoothing. We then present an adaptive, model-based microcalcification detection algorithm. Comparing detection results with ground-truth images obtained under the supervision of an expert radiologist allows us to establish the soundness of the detection algorithm. We measure the performance on the dose-reduced images in order to assess the loss of information due to dose reduction. It turns out that the smoothing behaviour has a strong influence on detection rates. For moderate smoothing, a dose reduction by 25% has no serious influence on the detection results, whereas a dose reduction by 50% already entails a marked deterioration of the performance. Strong smoothing generally leads to an unacceptable loss of image quality. The test results emphasize the impact of the more sensitive film-screen system and its characteristics on the problem of assessing the potential for dose reduction in film-screen mammography. The general approach presented in the paper can be adapted to fully digital mammography.

  19. An experimental investigation of the separating/reattaching flow over a backstep

    NASA Technical Reports Server (NTRS)

    Jovic, Srboljub

    1993-01-01

    This progress report covers the grant period from March until the end of January 1993. Extensive data reduction and analysis of single and two-point measurements for a backward-facing experiment were performed. Pertinent results are presented in two conference papers which are appended to this report. The titles of the papers are as follows: (1) 'Two-point correlation measurements in a recovering turbulent boundary layer'; and (2) 'An experimental study on the recovery of a turbulent boundary layer downstream of the reattachment'.

  20. Energy on the Home Front

    NASA Astrophysics Data System (ADS)

    Murphy, Thomas W.

    2011-11-01

    This article explores a variety of ways to measure, adjust, and augment home energy usage. Particular examples of using electricity and gas utility meters, power/energy meters for individual devices, whole-home energy monitoring, infrared cameras, and thermal measurements are discussed—leading to a factor-of-four reduction in home energy use in the case discussed. The net efficiency performance of a stand-alone photovoltaic system is also presented. Ideas for reducing one's energy/carbon footprint both within the home and in the larger community are quantitatively evaluated.

  1. Numerical and flight measured interior noise characteristics of a twin-engine turboprop general aviation aircraft

    NASA Astrophysics Data System (ADS)

    Marulo, F.; Lecce, L.; de Rosa, S.; D'Amato, C. A.; Verde, G.

    The paper presents the flight test results of an interior noise measurement campaign on a twin-engine turboprop general aviation aircraft conducted for assessing the real values inside such aircraft and for approaching the problem of its noise reduction. Simultaneously a numerical study has been performed in order to correlate the experimental and the theoretical values, trying to come out with some guidelines for possible improvements without increasing excessively the costs of such study.

  2. Noise Radiation from Single and Multiple Rod Configurations

    NASA Technical Reports Server (NTRS)

    Hutcheson, Florence V.; Brooks, Thomas F.

    2006-01-01

    Acoustic measurements were performed on single and multiple rod configurations to study the effect of Reynolds number, surface roughness, freestream turbulence, proximity and wake interference on the radiated noise. The Reynolds number ranged from 3.8 x 10(exp 3) to 10(exp 5). Directivity measurements were performed to determine how well the dipole assumption for the radiation of vortex shedding noise holds for the different model configurations tested. The dependence of the peak Sound Pressure Level on velocity was also examined. Several concepts for the reduction of the noise radiating from cylindrical rods were tested. It was shown that wire wraps and collar distributions could be used to significantly reduce the noise radiating from rods in tandem configurations.

  3. Adaptive self-regulation: meeting others' expectations of leadership and performance.

    PubMed

    Sosik, John J; Potosky, Denise; Jung, Dong I

    2002-04-01

    The authors used longitudinal multisource field data to examine core aspects of the adaptive self-regulation model (A. S. Tsui & S. J. Ashford, 1994) in terms of linkages between self-monitoring, discrepancy in manager match-to-position, 5 measures of leadership, and manager performance. At Time 1, 64 superiors of focal managers rated the managers' matches to their positions within the organization; at Time 3, they rated the managers' performance. At Time 2, the 64 focal managers completed a measure of self-monitoring, and 192 subordinates rated the focal managers' leadership behaviors. Results of partial least squares analysis revealed that discrepancy in manager match-to-position was associated with reductions in laissez faire and passive management-by-exception behaviors and increases in transformational leadership behavior. Self-monitoring was positively associated with all 5 leadership behaviors. Performance was related positively to transformational leadership behavior and negatively to passive management-by-exception and contingent-reward behaviors

  4. Long-term effects of brief hypoxia due to cardiac arrest: Hippocampal reductions and memory deficits.

    PubMed

    Stamenova, Vess; Nicola, Raneen; Aharon-Peretz, Judith; Goldsher, Dorith; Kapeliovich, Michael; Gilboa, Asaf

    2018-05-01

    To examine the effects of brief hypoxia (<7 min) due to cardiac arrest on the integrity of the brain and performance on memory and executive functions tasks. Patients after out-of-hospital cardiac arrest (CA) (n = 9), who were deemed neurologically intact on discharge, were compared to matched patients with myocardial infarction (MI) (n = 9). A battery of clinical and experimental memory and executive functions neuropsychological tests were administered and MRI scans for all patients were collected. Measures of subcortical and cortical volumes and cortical thickness were obtained using FreeSurfer. Manual segmentations of the hippocampus were also performed. APACHE-II scores were calculated based on metrics collected at admission to ICCU for all patients. Significant differences between the two groups were observed on several verbal memory tests. Both hippocampi were significantly reduced (p < 0.05) in the CA patients, relative to MI patients. Hippocampal subfields segmentation showed significantly reduced presubiculum volumes bilaterally. CA patients had on average 10% reduction in volumes bilaterally across hippocampal subfields. No cortical thickness differences survived correction. Significant correlations were observed in the CA group only between the hippocampal volumes and performance on verbal memory tasks, including recollection. Hippocampal volumes and several memory measures (but not other cognitive domains) were strongly correlated with APACHE-II scores on admission in the CA group, but not in the MI group CONCLUSIONS: Chronic patients with cardiac arrest who were discharged from hospital in "good neurological condition" showed an average of 10% reduction in hippocampal volume bilaterally and significant verbal memory deficits relative to matched controls with myocardial infarction, suggesting even brief hypoxic periods suffice to lead to specific hippocampal damage. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Impact of 5-aminolevulinic acid with iron supplementation on exercise efficiency and home-based walking training achievement in older women

    PubMed Central

    Masuki, Shizue; Morita, Atsumi; Kamijo, Yoshi-ichiro; Ikegawa, Shigeki; Kataoka, Yufuko; Ogawa, Yu; Sumiyoshi, Eri; Takahashi, Kiwamu; Tanaka, Tohru; Nakajima, Motowo

    2015-01-01

    A reduction in exercise efficiency with aging limits daily living activities. We examined whether 5-aminolevulinic acid (ALA) with sodium ferrous citrate (SFC) increased exercise efficiency and voluntary achievement of interval walking training (IWT) in older women. Ten women [65 ± 3(SD) yr] who had performed IWT for >12 mo and were currently performing IWT participated in this study. The study was conducted in a placebo-controlled, double-blind crossover design. All subjects underwent two trials for 7 days each in which they performed IWT with ALA+SFC (100 and 115 mg/day, respectively) or placebo supplement intake (CNT), intermittently with a 2-wk washout period. Before and after each trial, subjects underwent a graded cycling test at 27.0°C atmospheric temperature and 50% relative humidity, and oxygen consumption rate, carbon dioxide production rate, and lactate concentration in plasma were measured. Furthermore, for the first 6 days of each trial, exercise intensity for IWT was measured by accelerometry. We found that, in the ALA+SFC trial, oxygen consumption rate and carbon dioxide production rate during graded cycling decreased by 12% (P < 0.001) and 11% (P = 0.001) at every workload, respectively, accompanied by a 16% reduction in lactate concentration in plasma (P < 0.001), although all remained unchanged in the CNT trial (P > 0.2). All of the reductions were significantly greater in the ALA+SFC than the CNT trial (P < 0.05). Furthermore, the training days, impulse, and time at fast walking were 42% (P = 0.028), 102% (P = 0.027), and 69% (P = 0.039) higher during the ALA+SFC than the CNT intake period, respectively. Thus ALA+SFC supplementation augmented exercise efficiency and thereby improved IWT achievement in older women. PMID:26514619

  6. Prediction of cause of death from forensic autopsy reports using text classification techniques: A comparative study.

    PubMed

    Mujtaba, Ghulam; Shuib, Liyana; Raj, Ram Gopal; Rajandram, Retnagowri; Shaikh, Khairunisa

    2018-07-01

    Automatic text classification techniques are useful for classifying plaintext medical documents. This study aims to automatically predict the cause of death from free text forensic autopsy reports by comparing various schemes for feature extraction, term weighing or feature value representation, text classification, and feature reduction. For experiments, the autopsy reports belonging to eight different causes of death were collected, preprocessed and converted into 43 master feature vectors using various schemes for feature extraction, representation, and reduction. The six different text classification techniques were applied on these 43 master feature vectors to construct a classification model that can predict the cause of death. Finally, classification model performance was evaluated using four performance measures i.e. overall accuracy, macro precision, macro-F-measure, and macro recall. From experiments, it was found that that unigram features obtained the highest performance compared to bigram, trigram, and hybrid-gram features. Furthermore, in feature representation schemes, term frequency, and term frequency with inverse document frequency obtained similar and better results when compared with binary frequency, and normalized term frequency with inverse document frequency. Furthermore, the chi-square feature reduction approach outperformed Pearson correlation, and information gain approaches. Finally, in text classification algorithms, support vector machine classifier outperforms random forest, Naive Bayes, k-nearest neighbor, decision tree, and ensemble-voted classifier. Our results and comparisons hold practical importance and serve as references for future works. Moreover, the comparison outputs will act as state-of-art techniques to compare future proposals with existing automated text classification techniques. Copyright © 2017 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  7. On-road measurement of regulated pollutants from diesel and CNG buses with urea selective catalytic reduction systems

    NASA Astrophysics Data System (ADS)

    Guo, Jiadong; Ge, Yunshan; Hao, Lijun; Tan, Jianwei; Li, Jiaqiang; Feng, Xiangyu

    2014-12-01

    In this study, emissions from 13 buses operated in Beijing, including two Euro-III diesel buses, four Euro-IV diesel buses, three Euro-V diesel buses and four Euro-V CNG buses, were characterized in real world conditions. All of the buses tested were fitted with selective catalytic reduction (SCR) systems except for the Euro-III diesel buses. A SEMTECH-DS was used for testing the gaseous pollutants, and an electric low pressure impactor (ELPI) was used for measuring of particle numbers and size distributions. A comparison was made based on emission performance of these buses by employing the VSP approach and fuel- based emissions factors. Diesel buses emitted less CO and THC but more NOx and PM pollutants than CNG buses. The NOx reduction efficiencies of the SCR systems for CNG buses were higher because of the high exhaust temperature and high NO2/NOx ratio, whereas the efficiencies for diesel buses were lower. This resulted in extremely low NOx emissions from CNG buses, but the high NO2/NOx ratio needs further study. Failures of urea injection in the SCR systems were detected in this research, which resulted in very high NOx emissions. The CNG buses also emitted smaller numbers of particles and less particle mass with the presence of oxidation catalysts. Diesel buses satisfying the Euro-V standard performed better than Euro-IV and Euro-III diesel buses in terms of emission performance, except for more nuclei mode particles. Most of time, the Euro-IV diesel buses show no advantages in CO and NOx emissions compared with the Euro-III diesel buses.

  8. Evaluation of SSME test data reduction methods

    NASA Technical Reports Server (NTRS)

    Santi, L. Michael

    1994-01-01

    Accurate prediction of hardware and flow characteristics within the Space Shuttle Main Engine (SSME) during transient and main-stage operation requires a significant integration of ground test data, flight experience, and computational models. The process of integrating SSME test measurements with physical model predictions is commonly referred to as data reduction. Uncertainties within both test measurements and simplified models of the SSME flow environment compound the data integration problem. The first objective of this effort was to establish an acceptability criterion for data reduction solutions. The second objective of this effort was to investigate the data reduction potential of the ROCETS (Rocket Engine Transient Simulation) simulation platform. A simplified ROCETS model of the SSME was obtained from the MSFC Performance Analysis Branch . This model was examined and tested for physical consistency. Two modules were constructed and added to the ROCETS library to independently check the mass and energy balances of selected engine subsystems including the low pressure fuel turbopump, the high pressure fuel turbopump, the low pressure oxidizer turbopump, the high pressure oxidizer turbopump, the fuel preburner, the oxidizer preburner, the main combustion chamber coolant circuit, and the nozzle coolant circuit. A sensitivity study was then conducted to determine the individual influences of forty-two hardware characteristics on fourteen high pressure region prediction variables as returned by the SSME ROCETS model.

  9. Quantitative measurement of radiofrequency volumetric tissue reduction by multidetector CT in patients with inferior turbinate hypertrophy.

    PubMed

    Bahadir, Osman; Kosucu, Polat

    2012-12-01

    To objectively assess the efficacy of radiofrequency thermal ablation of inferior turbinate hypertrophy. Thirty-five patients with nasal obstruction secondary to inferior turbinate hypertrophy were prospectively enrolled. Radiofrequency energy was delivered to four sites in each inferior turbinate. Patients were evaluated before and 8 weeks after intervention. Subjective evaluation of nasal obstruction was performed using a visual analogue scale (VAS), and objective evaluation of the turbinate volume reduction was calculated using multidetector CT. Volumetric measurements of the preoperative inferior turbinate were compared with postoperative values on both sides. The great majority of patients (91.4%) exhibited subjective postoperative improvement. Mean obstruction (VAS) improved significantly from 7.45±1.48 to 3.54±1.96. Significant turbinate volume reduction was achieved by the surgery on both right and left sides [(preoperative vs. postoperative, right: 6.55±1.62cm(3) vs. 5.10±1.47cm(3), (P<0.01); left: 6.72±1.53cm(3) vs. 5.00±1.37cm(3), (P<0.01)] respectively. Radiofrequency is a safe and effective surgical procedure in reducing turbinate volume in patients with inferior turbinate hypertrophy. Multidetector CT is an objective method of assessment in detecting radiofrequency turbinate volume reduction. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  10. Anti-inflammatory and anti-pyretic properties of Spirulina platensis and Spirulina lonar: a comparative study.

    PubMed

    Somchit, Muhammad Nazrul; Mohamed, Nor Azura; Ahmad, Zuraini; Zakaria, Zainul Amiruddin; Shamsuddin, Lokman; Omar-Fauzee, Mohd Sofian; Kadir, Arifah Abdul

    2014-09-01

    Spirulina spp. is a blue-green algae belongs to the family of Oscillatoriaceae, which having diverse biological activity. The aim of this current study was to evaluate and compare the anti-pyretic and anti-inflammatory activity of Spirulina platensis/SP and Spirulina lonar/SL extracts. In the anti-pyretic study, the ability to reduce the rectal temperature of rats induced pyrexia with 2g/kg Brewer's Yeast (BY) was performed. Rats were dosed either 2 or 4 mg/kg SP or SL. Rectal temperature was taken every hour for 8 hours. Results shown that there were significant dose-dependent (p<0.05) reduction of both treatments. However, SP treatment revealed faster reduction in rectal temperature. For anti-inflammatory activity, the reduction in the volume of paw edema induced by Prostaglandin E2 (100 IU/rat intraplantar) was measured. Rats were dosed orally with 2 or 4 mg/kg SP or SL. The paw edema was measured every 30 minutes for 4 hours using plethysmometer. Results had shown a significant dose dependent reduction in diameter of paw edema (p<0.05). The finding suggests that SP and SL extracts have anti-pyretic and anti-inflammatory properties. However, SP was found to be more effective than SL as anti-pyretic and anti-inflammatory agent.

  11. A Formula for Planning and Predicting Postoperative Mammoplasty Results.

    PubMed

    Smithson, Mary G; Collawn, Sherry S; Mousa, Mina S; Bramel, Carly M

    2017-06-01

    For women with macromastia, reduction mammoplasty is a safe and effective solution to increasing quality of life through alleviating pain and improving aesthetics. This study developed a way to combine a surgeon's view of breast measurement (volume) with a patient's view of breast measurement (distance between nipple and notch, inframammary fold, or midline) to provide patients with a better understanding of expected surgical outcomes after breast reduction with a medial superior pedicle. An institutional review board approved retrospective chart review was performed on all medial superior pedicle reduction mammoplasties performed by a single surgeon at a university medical center from 2008 to 2016, and a total of 133 patients were identified. Measurements of interest for this study were nipple to sternal notch (N-S), nipple to inframammary fold (N-I), nipple to midline (N-M), and breast diameter (BD). The average bilateral change per measurement was calculated for each patient in centimeters. Change was averaged for left and right breasts for N-S, N-I, N-M, and BD per patient. Grams removed for left and right breasts were also averaged. Each measurement of average change was divided by the gram average and multiplied by 100 to obtain centimeter change per 100 grams. Individual patient measurements per type of measurement were averaged to achieve a final improvement reported in centimeters per 100 g tissue removed per breast. The average change in the N-S distance was calculated to be a decrease of 1.5 ± 0.8 cm/100 g of breast tissue removed. The average change in N-I was calculated to be an overall decrease of 0.7 ± 0.5 cm/100 g. The average change in N-M was calculated to be a decrease of 0.1 ± 0.3 cm/100 g. Finally, the average change in BD was calculated to be 0.0 ± 0.4 cm/100 g. A surgeon's expression of breast measurements in terms of volume can be difficult for a patient to understand and visualize. This study determined the impact volume has on length of typical breast measurements to increase patients' understanding of expected outcomes. In summary, patients can be told to expect to see a nipple elevation of 1.5 cm per 100 grams of breast tissue removed using this medial superior pedicle technique.

  12. Application of electrospray ionization hybrid ion trap/time-of-flight mass spectrometry in the rapid characterization of quinocetone metabolites formed in vitro.

    PubMed

    Liu, Zhao-Ying; Huang, Ling-Li; Chen, Dong-Mei; Dai, Meng-Hong; Tao, Yan-Fei; Wang, Yu-Lian; Yuan, Zong-Hui

    2010-02-01

    The application of electrospray ionization hybrid ion trap/time-of-flight mass spectrometry coupled with high-performance liquid chromatography (LC/MS-IT-TOF) in the rapid characterization of in vitro metabolites of quinocetone was developed. Metabolites formed in rat liver microsomes were separated using a VP-ODS column with gradient elution. Multiple scans of metabolites in MS and MS(2) modes and accurate mass measurements were automatically performed simultaneously through data-dependent acquisition in only a 30-min analysis. Most measured mass errors were less than 10 ppm for both protonated molecules and fragment ions using external mass calibration. The elemental compositions of all fragment ions of quinocetone and its metabolites could be rapidly assigned based upon the known compositional elements of protonated molecules. The structure of metabolites were elucidated based on the combination of three techniques: agreement between their proposed structure, the accurate masses, and the elemental composition of ions in their mass spectra; comparison of their changes in accurate molecular masses and fragment ions with those of parent drug or metabolite; and the elemental compositions of lost mass numbers in proposed fragmentation pathways. Twenty-seven phase I metabolites were identified as 11 reduction metabolites, three direct hydroxylation metabolites, and 13 metabolites with a combination of reduction and hydroxylation. All metabolites except the N-oxide reduction metabolite M6 are new metabolites of quinocetone, which were not previously reported. The ability to conduct expected biotransformation profiling via tandem mass spectrometry coupled with accurate mass measurement, all in a single experimental run, is one of the most attractive features of this methodology. The results demonstrate the use of LC/MS-IT-TOF approach appears to be rapid, efficient, and reliable in structural characterization of drug metabolites.

  13. Optical coherence tomography applied to tests of skin care products in humans--a case study.

    PubMed

    Vasquez-Pinto, L M C; Maldonado, E P; Raele, M P; Amaral, M M; de Freitas, A Z

    2015-02-01

    When evaluating skin care products for human skin, quantitative test methods need to be simple, precise and reliable. Optical coherence tomography (OCT), provides high-resolution sectional images of translucent materials to a depth of a few millimeters, a technique usually applied to medical measurements in ophthalmology and dermatology. This study aimed to demonstrate the application of OCT as the main technique for monitoring changes in skin topography during tests of a wrinkle-reduction product in humans. We used a commercial OCT apparatus to perform clinical examinations of skin roughness in treated and non-treated sites in the periorbital region of thirty human voluntaries who were using an anti-aging product commercially available: Natura Chronos® Flavonóides de Passiflora 45+ FPS15, from Natura Cosméticos, Brazil. Measurements were performed days 0, 7, 14 and 28 of treatment. Equipment and software allowed real-time recording of skin roughness parameters and wrinkle depths. The OCT measurements have allowed the monitoring of changes in skin roughness, which have shown reduction in treated sites around 10%. The obtained depth distributions also indicate reduction in the occurrence of wrinkles deeper than 170 μm. The verified results are consistent with those typically obtained after successful treatment with modern anti-aging products. By using the OCT technique, it was possible to quantify changes in skin roughness and in the distribution of depths of skin wrinkles, with adequate sensitivity. OCT imaging allows the direct visualization of the skin topography with resolution of micrometers, a reliable and interactive tool for clinical use. Therefore, for the first time, we demonstrated the use of OCT technique to verify the efficacy of cosmetic products in real time. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Investigation of Optimal Digital Image Correlation Patterns for Deformation Measurement

    NASA Technical Reports Server (NTRS)

    Bomarito, G. F.; Ruggles, T. J.; Hochhalter, J. D.; Cannon, A. H.

    2016-01-01

    Digital image correlation (DIC) relies on the surface texture of a specimen to measure deformation. When the specimen itself has little or no texture, a pattern is applied to the surface which deforms with the specimen and acts as an artificial surface texture. Because the applied pattern has an effect on the accuracy of DIC, an ideal pattern is sought for which the error introduced into DIC measurements is minimal. In this work, a study is performed in which several DIC pattern quality metrics from the literature are correlated to DIC measurement error. The resulting correlations give insight on the optimality of DIC patterns in general. Optimizations are then performed to produce patterns which are well suited for DIC. These patterns are tested to show their relative benefits. Chief among these benefits are a reduction in error of approximately 30 with respect to a randomly generated pattern.

  15. X-wing noise data acquisition program

    NASA Technical Reports Server (NTRS)

    Healy, G. J.

    1983-01-01

    The X-wing circulation controlled rotor system model was tested for hover performance. During these performance tests, noise data from 12 microphones was recorded on magnetic tape for subsequent data reduction. The rotor system was operated at 4 tip speeds ranging from 529 to 650 ft./sec. (404 to 497 rpm), collective angles of attack fro 0 deg to 8.5 deg (maximum), and blade pressure ratios from 1.0 (no blowing) to a maximum of 2.1. The 12 microphones included 11 in the far field, and one in the transmission area. Following completion of the rotor and subsystem noise measurements, sound field calibration measurements were made of both the rotor 'bowl' and the loudspeaker system used in the 'bowl' calibration measurements. The location of 10 far field microphones was measured by a surveyor. Additionally, detailed tape logs were prepared for the six reels of tape used for the program.

  16. Sufficient Dimension Reduction for Longitudinally Measured Predictors

    PubMed Central

    Pfeiffer, Ruth M.; Forzani, Liliana; Bura, Efstathia

    2013-01-01

    We propose a method to combine several predictors (markers) that are measured repeatedly over time into a composite marker score without assuming a model and only requiring a mild condition on the predictor distribution. Assuming that the first and second moments of the predictors can be decomposed into a time and a marker component via a Kronecker product structure, that accommodates the longitudinal nature of the predictors, we develop first moment sufficient dimension reduction techniques to replace the original markers with linear transformations that contain sufficient information for the regression of the predictors on the outcome. These linear combinations can then be combined into a score that has better predictive performance than the score built under a general model that ignores the longitudinal structure of the data. Our methods can be applied to either continuous or categorical outcome measures. In simulations we focus on binary outcomes and show that our method outperforms existing alternatives using the AUC, the area under the receiver-operator characteristics (ROC) curve, as a summary measure of the discriminatory ability of a single continuous diagnostic marker for binary disease outcomes. PMID:22161635

  17. Relationship between light scattering and absorption due to cytochrome c oxidase reduction during loss of tissue viability in brains of rats

    NASA Astrophysics Data System (ADS)

    Kawauchi, Satoko; Sato, Shunichi; Ooigawa, Hidetoshi; Nawashiro, Hiroshi; Ishihara, Miya; Kikuchi, Makoto

    2008-02-01

    We performed simultaneous measurement of light scattering and absorption due to reduction of cytochrome c oxidase as intrinsic optical signals that are related to morphological characteristics and energy metabolism, respectively, for rat brains after oxygen/glucose deprivation by saline infusion. To detect change in light scattering, we determined the wavelength that was the most insensitive to change in light absorption due to the reduction of cytochrome c oxidase on the basis of multiwavelength analysis of diffuse reflectance data set for each rat. Then the relationships between scattering signal and absorption signals related to the reductions of heme aa 3 (605 nm) and CuA (830 nm) in cytochrome c oxidase were examined. Measurements showed that after starting saline infusion, the reduction of heme aa 3 started first; thereafter triphasic, large scattering change occurred (200-300 s), during which the reduction of CuA started. Despite such complex behaviors of IOSs, almost linear correlations were seen between the scattering signal and the heme aa 3-related absorption signal, while a relatively large animal-to-animal variation was observed in the correlation between the scattering signal and CuA-related absorption signal. Transmission electron microscopic observation revealed that dendritic swelling and mitochondrial deformation occurred in the cortical surface tissue after the triphasic scattering change. These results suggest that mitochondrial energy failure accompanies morphological alteration in the brain tissue and results in change in light scattering; light scattering will become an important indicator of tissue viability in brain.

  18. Pulsed plasma thruster contamination studies

    NASA Technical Reports Server (NTRS)

    Rudolph, L. K.; Jones, R. M.

    1979-01-01

    The exhaust plume of the one millipound pulsed plasma thruster has a measurable backflow upstream of the nozzle exit plane which may deposit on and degrade the performance of exposed spacecraft surfaces. High speed photographs and Faraday cup measurements suggest that this backflow is predominantly an electrically neutral, relatively low energy vapor. Articulated collimator quartz crystal microbalance measurements of this backflow were made for a thruster with a radically modified nozzle and a flat plate backflow shield, to determine the backflow sensitivity to nozzle design changes. The results are compared with the original nozzle backflow and show a measurable reduction in the backflow directly upstream of the shield.

  19. Surface dose measurements from air gaps under a bolus by using a MOSFET dosimeter in clinical oblique photon beams

    NASA Astrophysics Data System (ADS)

    Chung, Jin-Beom; Kim, Jae-Sung; Kim, In-Ah; Lee, Jeong-Woo

    2012-10-01

    This study is intended to investigate the effects of surface dose from air gaps under the bolus in clinically used oblique photon beams by using a Markus parallel-plate chamber and a metal-oxide semiconductor field-effect transistor (MOSFET) dosimeter. To evaluate the performances of the two detectors, the percentage surface doses of the MOSFET dosimeters in without an air gap under the bolus material were measured and compared with those of the Markus parallel-plate chamber. MOSFET dosimeters at the surface provided results mostly in good agreement with the parallelplate chamber. The MOSFET dosimeters seemed suitable for surface dose measurements having excellent accuracy for clinical used photon beams. The relative surface doses were measured with air gaps (2, 5, 10 mm) and without an air gap under 3 different bolus setups: (1) unbolused (no bolus), (2) 5-mm bolus, and (3) 10-mm bolus. The reductions in the surface dose substantially increased with small field size, thick bolus, and large air gap. The absolute difference in the reductions of the surface dose between the MOSFET dosimeter and the Markus parallel-plate chamber was less than 1.1%. Results at oblique angles of incidence showed larger reductions in surface dose with increasing angle of incidence. The largest reduction in surface dose was recorded for a 6 × 6 cm2 field at a 60° angle of incidence with an 10-mm air gap under a 10-mm bolus. When a 10-mm bolus was used, a reduction in the surface dose with an air gap of up to 10.5% could be achieved by varying the field size and the incident angle. Therefore, air gaps under the bolus should be avoided in radiotherapy treatment, especially for photon beam with highly oblique angles of incidence.

  20. Editor's choice--Use of disposable radiation-absorbing surgical drapes results in significant dose reduction during EVAR procedures.

    PubMed

    Kloeze, C; Klompenhouwer, E G; Brands, P J M; van Sambeek, M R H M; Cuypers, P W M; Teijink, J A W

    2014-03-01

    Because of the increasing number of interventional endovascular procedures with fluoroscopy and the corresponding high annual dose for interventionalists, additional dose-protecting measures are desirable. The purpose of this study was to evaluate the effect of disposable radiation-absorbing surgical drapes in reducing scatter radiation exposure for interventionalists and supporting staff during an endovascular aneurysm repair (EVAR) procedure. This was a randomized control trial in which 36 EVAR procedures were randomized between execution with and without disposable radiation-absorbing surgical drapes (Radpad: Worldwide Innovations & Technologies, Inc., Kansas City, US, type 5511A). Dosimetric measurements were performed on the interventionalist (hand and chest) and theatre nurse (chest) with and without the use of the drapes to obtain the dose reduction and effect on the annual dose caused by the drapes. Use of disposable radiation-absorbing surgical drapes resulted in dose reductions of 49%, 55%, and 48%, respectively, measured on the hand and chest of the interventionalist and the chest of the theatre nurse. The use of disposable radiation-absorbing surgical drapes significantly reduces scatter radiation exposure for both the interventionalist and the supporting staff during EVAR procedures. Copyright © 2013 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  1. Aeroacoustic Evaluation of Flap and Landing Gear Noise Reduction Concepts

    NASA Technical Reports Server (NTRS)

    Khorrami, Mehdi R.; Humphreys, William M., Jr.; Lockard, David P.; Ravetta, Patricio A.

    2014-01-01

    Aeroacoustic measurements for a semi-span, 18% scale, high-fidelity Gulfstream aircraft model are presented. The model was used as a test bed to conduct detailed studies of flap and main landing gear noise sources and to determine the effectiveness of numerous noise mitigation concepts. Using a traversing microphone array in the flyover direction, an extensive set of acoustic data was obtained in the NASA Langley Research Center 14- by 22-Foot Subsonic Tunnel with the facility in the acoustically treated open-wall (jet) mode. Most of the information was acquired with the model in a landing configuration with the flap deflected 39 deg and the main landing gear alternately installed and removed. Data were obtained at Mach numbers of 0.16, 0.20, and 0.24 over directivity angles between 56 deg and 116 deg, with 90 deg representing the overhead direction. Measured acoustic spectra showed that several of the tested flap noise reduction concepts decrease the sound pressure levels by 2 - 4 dB over the entire frequency range at all directivity angles. Slightly lower levels of noise reduction from the main landing gear were obtained through the simultaneous application of various gear devices. Measured aerodynamic forces indicated that the tested gear/flap noise abatement technologies have a negligible impact on the aerodynamic performance of the aircraft model.

  2. Estimating the Fiscal Effects of Public Pharmaceutical Expenditure Reduction in Greece.

    PubMed

    Souliotis, Kyriakos; Papageorgiou, Manto; Politi, Anastasia; Frangos, Nikolaos; Tountas, Yiannis

    2015-01-01

    The purpose of the present study is to estimate the impact of pharmaceutical spending reduction on public revenue, based on data from the national health accounts as well as on reports of Greece's organizations. The methodology of the analysis is structured in two basic parts. The first part presents the urgency for rapid cutbacks on public pharmaceutical costs due to the financial crisis and provides a conceptual framework for the contribution of the Greek pharmaceutical branch to the country's economy. In the second part, we perform a quantitative analysis for the estimation of multiplier effects of public pharmaceutical expenditure reduction on main revenue sources, such as taxes and social contributions. We also fit projection models with multipliers as regressands for the evaluation of the efficiency of the particular fiscal measure in the short run. According to the results, nearly half of the gains from the measure's application is offset by financially equivalent decreases in the government's revenue, i.e., losses in tax revenues and social security contributions alone, not considering any other direct or indirect costs. The findings of multipliers' high value and increasing short-term trend imply the measure's inefficiency henceforward and signal the risk of vicious circles that will provoke the economy's deprivation of useful resources.

  3. Reliable intraocular pressure measurement using automated radio-wave telemetry

    PubMed Central

    Paschalis, Eleftherios I; Cade, Fabiano; Melki, Samir; Pasquale, Louis R; Dohlman, Claes H; Ciolino, Joseph B

    2014-01-01

    Purpose To present an autonomous intraocular pressure (IOP) measurement technique using a wireless implantable transducer (WIT) and a motion sensor. Methods The WIT optical aid was implanted within the ciliary sulcus of a normotensive rabbit eye after extracapsular clear lens extraction. An autonomous wireless data system (AWDS) comprising of a WIT and an external antenna aided by a motion sensor provided continuous IOP readings. The sensitivity of the technique was determined by the ability to detect IOP changes resulting from the administration of latanoprost 0.005% or dorzolamide 2%, while the reliability was determined by the agreement between baseline and vehicle (saline) IOP. Results On average, 12 diurnal and 205 nocturnal IOP measurements were performed with latanoprost, and 26 diurnal and 205 nocturnal measurements with dorzolamide. No difference was found between mean baseline IOP (13.08±2.2 mmHg) and mean vehicle IOP (13.27±2.1 mmHg) (P=0.45), suggesting good measurement reliability. Both antiglaucoma medications caused significant IOP reduction compared to baseline; latanoprost reduced mean IOP by 10% (1.3±3.54 mmHg; P<0.001), and dorzolamide by 5% (0.62±2.22 mmHg; P<0.001). Use of latanoprost resulted in an overall twofold higher IOP reduction compared to dorzolamide (P<0.001). Repeatability was ±1.8 mmHg, assessed by the variability of consecutive IOP measurements performed in a short period of time (≤1 minute), during which the IOP is not expected to change. Conclusion IOP measurements in conscious rabbits obtained without the need for human interactions using the AWDS are feasible and provide reproducible results. PMID:24531415

  4. Multi-wavelength speckle reduction for laser pico-projectors using diffractive optics

    NASA Astrophysics Data System (ADS)

    Thomas, Weston H.

    Personal electronic devices, such as cell phones and tablets, continue to decrease in size while the number of features and add-ons keep increasing. One particular feature of great interest is an integrated projector system. Laser pico-projectors have been considered, but the technology has not been developed enough to warrant integration. With new advancements in diode technology and MEMS devices, laser-based projection is currently being advanced for pico-projectors. A primary problem encountered when using a pico-projector is coherent interference known as speckle. Laser speckle can lead to eye irritation and headaches after prolonged viewing. Diffractive optical elements known as diffusers have been examined as a means to lower speckle contrast. Diffusers are often rotated to achieve temporal averaging of the spatial phase pattern provided by diffuser surface. While diffusers are unable to completely eliminate speckle, they can be utilized to decrease the resultant contrast to provide a more visually acceptable image. This dissertation measures the reduction in speckle contrast achievable through the use of diffractive diffusers. A theoretical Fourier optics model is used to provide the diffuser's stationary and in-motion performance in terms of the resultant contrast level. Contrast measurements of two diffractive diffusers are calculated theoretically and compared with experimental results. In addition, a novel binary diffuser design based on Hadamard matrices will be presented. Using two static in-line Hadamard diffusers eliminates the need for rotation or vibration of the diffuser for temporal averaging. Two Hadamard diffusers were fabricated and contrast values were subsequently measured, showing good agreement with theory and simulated values. Monochromatic speckle contrast values of 0.40 were achieved using the Hadamard diffusers. Finally, color laser projection devices require the use of red, green, and blue laser sources; therefore, using a monochromatic diffractive diffuser may not optimal for color speckle contrast reduction. A simulation of the Hadamard diffusers is conducted to determine the optimum spacing between the two diffusers for polychromatic speckle reduction. Experimental measured results are presented using the optimal spacing of Hadamard diffusers for RGB color speckle reduction, showing 60% reduction in contrast.

  5. Global tropospheric experiment at the Hong Kong Atmosphere Chemistry Measurement Station

    NASA Technical Reports Server (NTRS)

    Carroll, Mary Ann; Wang, Tao

    1995-01-01

    The major activities of the Global Tropospheric Experiment at the Hong Kong Atmospheric Chemistry Measurement Station are presented for the period 1 January - 31 December 1995. Activities included data analysis, reduction, and archiving of atmospheric measurements and sampling. Sampling included O3, CO, SO2, NO, TSP, RSP, and ozone column density. A data archive was created for the surface meteorological data. Exploratory data analysis was performed, including examination of time series, frequency distributions, diurnal variations and correlation. The major results have been or will be published in scientific journals as well as presented at conferences/workshops. Abstracts are attached.

  6. Efficacy of a radiation absorbing shield in reducing dose to the interventionalist during peripheral endovascular procedures: a single centre pilot study.

    PubMed

    Power, S; Mirza, M; Thakorlal, A; Ganai, B; Gavagan, L D; Given, M F; Lee, M J

    2015-06-01

    This prospective pilot study was undertaken to evaluate the feasibility and effectiveness of using a radiation absorbing shield to reduce operator dose from scatter during lower limb endovascular procedures. A commercially available bismuth shield system (RADPAD) was used. Sixty consecutive patients undergoing lower limb angioplasty were included. Thirty procedures were performed without the RADPAD (control group) and thirty with the RADPAD (study group). Two separate methods were used to measure dose to a single operator. Thermoluminescent dosimeter (TLD) badges were used to measure hand, eye, and unshielded body dose. A direct dosimeter with digital readout was also used to measure eye and unshielded body dose. To allow for variation between control and study groups, dose per unit time was calculated. TLD results demonstrated a significant reduction in median body dose per unit time for the study group compared with controls (p = 0.001), corresponding to a mean dose reduction rate of 65 %. Median eye and hand dose per unit time were also reduced in the study group compared with control group, however, this was not statistically significant (p = 0.081 for eye, p = 0.628 for hand). Direct dosimeter readings also showed statistically significant reduction in median unshielded body dose rate for the study group compared with controls (p = 0.037). Eye dose rate was reduced for the study group but this was not statistically significant (p = 0.142). Initial results are encouraging. Use of the shield resulted in a statistically significant reduction in unshielded dose to the operator's body. Measured dose to the eye and hand of operator were also reduced but did not reach statistical significance in this pilot study.

  7. Noise Exposure of Teachers in Nursery Schools—Evaluation of Measures for Noise Reduction When Dropping DUPLO Toy Bricks into Storage Cases by Sound Analyses

    PubMed Central

    Gebauer, Konstanze; Scharf, Thomas; Baumann, Uwe; Groneberg, David A.; Bundschuh, Matthias

    2016-01-01

    Background: Although noise is one of the leading work-related health risk factors for teachers, many nursery schools lack sufficient noise reduction measures. Methods: This intervention study evaluated the noise exposure of nursery school teachers when dropping DUPLO toy bricks into storage cases. Sound analyses of the impact included assessment of the maximum sound pressure level (LAFmax) as well as frequency analyses with 1/3 octave band filter. For the purpose of standardization, a customized gadget was developed. Recordings were performed in 11 cases of different materials and designs to assess the impact on sound level reduction. Thereby, the acoustic effects of three damping materials (foam rubber, carpet, and PU-foam) were investigated. Results: The lowest LAFmax was measured in cases consisting of “metal grid” (90.71 dB) or of a woven willow “basket” (91.61 dB), whereas a case of “aluminium” (103.34 dB) generated the highest impact LAFmax. The frequency analyses determined especially low LAFmax in the frequency bands between 80 and 2500 Hz in cases designs “metal grid” and “basket”. The insertion of PU-foam achieved the most significant attenuation of LAFmax (−13.88 dB) and, in the frequency analyses, the best sound damping. Conclusion: The dropping of DUPLO bricks in cases contributes to the high noise level in nursery schools, but measured LAFmax show no evidence for the danger of acute hearing loss. However, continuous exposure may lead to functional impairment of the hair cells and trigger stress reactions. We recommend noise reduction by utilizing cases of woven “basket” with an insert of PU-foam. PMID:27384575

  8. Noise Exposure of Teachers in Nursery Schools-Evaluation of Measures for Noise Reduction When Dropping DUPLO Toy Bricks into Storage Cases by Sound Analyses.

    PubMed

    Gebauer, Konstanze; Scharf, Thomas; Baumann, Uwe; Groneberg, David A; Bundschuh, Matthias

    2016-07-04

    Although noise is one of the leading work-related health risk factors for teachers, many nursery schools lack sufficient noise reduction measures. This intervention study evaluated the noise exposure of nursery school teachers when dropping DUPLO toy bricks into storage cases. Sound analyses of the impact included assessment of the maximum sound pressure level (LAFmax) as well as frequency analyses with 1/3 octave band filter. For the purpose of standardization, a customized gadget was developed. Recordings were performed in 11 cases of different materials and designs to assess the impact on sound level reduction. Thereby, the acoustic effects of three damping materials (foam rubber, carpet, and PU-foam) were investigated. The lowest LAFmax was measured in cases consisting of "metal grid" (90.71 dB) or of a woven willow "basket" (91.61 dB), whereas a case of "aluminium" (103.34 dB) generated the highest impact LAFmax. The frequency analyses determined especially low LAFmax in the frequency bands between 80 and 2500 Hz in cases designs "metal grid" and "basket". The insertion of PU-foam achieved the most significant attenuation of LAFmax (-13.88 dB) and, in the frequency analyses, the best sound damping. The dropping of DUPLO bricks in cases contributes to the high noise level in nursery schools, but measured LAFmax show no evidence for the danger of acute hearing loss. However, continuous exposure may lead to functional impairment of the hair cells and trigger stress reactions. We recommend noise reduction by utilizing cases of woven "basket" with an insert of PU-foam.

  9. Evaluation of energy in heated water vapor for the application of lung volume reduction in patients with severe emphysema.

    PubMed

    Henne, Erik; Kesten, Steven; Herth, Felix J F

    2013-01-01

    A method of achieving endoscopic lung volume reduction for emphysema has been developed that utilizes precise amounts of thermal energy in the form of water vapor to ablate lung tissue. This study evaluates the energy output and implications of the commercial InterVapor system and compares it to the clinical trial system. Two methods of evaluating the energy output of the vapor systems were used, a direct energy measurement and a quantification of resultant thermal profile in a lung model. Direct measurement of total energy and the component attributable to gas (vapor energy) was performed by condensing vapor in a water bath and measuring the temperature and mass changes. Infrared images of a lung model were taken after vapor delivery. The images were quantified to characterize the thermal profile. The total energy and vapor energy of the InterVapor system was measured at various dose levels and compared to the clinical trial system at a dose of 10.0 cal/g. An InterVapor dose of 8.5 cal/g was found to have the most similar vapor energy output with the smallest associated reduction in total energy. This was supported by characterization of the thermal profile in the lung model that demonstrated the profile of InterVapor at 8.5 cal/g to not exceed the profile of the clinical trial system. Considering both total energy and vapor energy is important during the development of clinical vapor applications. For InterVapor, a closer study of both energy types justified a reduced target vapor-dosing range for lung volume reduction. The clinical implication is a potential improvement for benefiting the risk profile. Copyright © 2013 S. Karger AG, Basel.

  10. Assessment of health benefits related to air quality improvement strategies in urban areas: An Impact Pathway Approach.

    PubMed

    Silveira, Carlos; Roebeling, Peter; Lopes, Myriam; Ferreira, Joana; Costa, Solange; Teixeira, João P; Borrego, Carlos; Miranda, Ana I

    2016-12-01

    Air pollution is, increasingly, a concern to our society given the threats to human health and the environment. Concerted actions to improve air quality have been taken at different levels, such as through the development of Air Quality Plans (AQPs). However, air quality impacts associated with the implementation of abatement measures included in AQPs are often neglected. In order to identify the major gaps and strengths in current knowledge, a literature review has been performed on existing methodologies to estimate air pollution-related health impacts and subsequent external costs. Based on this review, the Impact Pathway Approach was adopted and applied within the context of the MAPLIA research project to assess the health impacts and benefits (or avoided external costs) derived from improvements in air quality. Seven emission abatement scenarios, based on individual and combined abatement measures, were tested for the major activity sectors (traffic, residential and industrial combustion and production processes) of a Portuguese urban area (Grande Porto) with severe particular matter (PM10) air pollution problems. Results revealed a strong positive correlation between population density and health benefits obtained from the assessed reduction scenarios. As a consequence, potential health benefits from reduction scenarios are largest in densely populated areas with high anthropic activity and, thus, where air pollution problems are most alarming. Implementation of all measures resulted in a reduction in PM10 emissions by almost 8%, improving air quality by about 1% and contributing to a benefit of 8.8 million €/year for the entire study domain. The introduction of PM10 reduction technologies in industrial units was the most beneficial abatement measure. This study intends to contribute to policy support for decision-making on air quality management. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Direct electrochemical reduction of solid uranium oxide in molten fluoride salts

    NASA Astrophysics Data System (ADS)

    Gibilaro, Mathieu; Cassayre, Laurent; Lemoine, Olivier; Massot, Laurent; Dugne, Olivier; Malmbeck, Rikard; Chamelot, Pierre

    2011-07-01

    The direct electrochemical reduction of UO 2 solid pellets was carried out in LiF-CaF 2 (+2 mass.% Li 2O) at 850 °C. An inert gold anode was used instead of the usual reactive sacrificial carbon anode. In this case, oxidation of oxide ions present in the melt yields O 2 gas evolution on the anode. Electrochemical characterisations of UO 2 pellets were performed by linear sweep voltammetry at 10 mV/s and reduction waves associated to oxide direct reduction were observed at a potential 150 mV more positive in comparison to the solvent reduction. Subsequent, galvanostatic electrolyses runs were carried out and products were characterised by SEM-EDX, EPMA/WDS, XRD and microhardness measurements. In one of the runs, uranium oxide was partially reduced and three phases were observed: nonreduced UO 2 in the centre, pure metallic uranium on the external layer and an intermediate phase representing the initial stage of reduction taking place at the grain boundaries. In another run, the UO 2 sample was fully reduced. Due to oxygen removal, the U matrix had a typical coral-like structure which is characteristic of the pattern observed after the electroreduction of solid oxides.

  12. Impact of presentation of research results on likelihood of prescribing medications to patients with left ventricular dysfunction.

    PubMed

    Lacy, C R; Barone, J A; Suh, D C; Malini, P L; Bueno, M; Moylan, D M; Kostis, J B

    2001-01-15

    This study was conducted to evaluate willingness to prescribe medication based on identical data presented in different outcome terms to health professionals of varied discipline, geographic location, and level of training. Cross-sectional survey using a self-administered questionnaire was performed in 400 health professionals (physicians, pharmacists, physicians-in-training, and pharmacy students) in the United States and Europe. Data reflecting a clinical trial were presented in 6 outcome terms: 3 terms describing identical mortality (relative risk reduction, absolute risk reduction, and number of patients needed to be treated to prevent 1 death); and 3 distractors (increased life expectancy, decreased hospitalization rate, and decreased cost). Willingness to prescribe and rank order of medication preference assuming willingness to prescribe were measured. The results of the study showed that willingness to prescribe and first choice preference were significantly greater when study results were presented as relative risk reduction than when identical mortality data were presented as absolute risk reduction or number of patients needed to be treated to avoid 1 death (p <0.001). Increase in life expectancy was the most influential distractor. In conclusion, this study, performed in the era of "evidence-based medicine," demonstrates that the method of reporting research trial results has significant influence on health professionals' willingness to prescribe. The high numerical value of relative risk reduction and the concrete and tangible quality of increased life expectancy exert greater influence on health professionals than other standard outcome terms.

  13. Effect of a national primary care pay for performance scheme on emergency hospital admissions for ambulatory care sensitive conditions: controlled longitudinal study

    PubMed Central

    Harrison, Mark J; Dusheiko, Mark; Sutton, Matt; Gravelle, Hugh; Doran, Tim

    2014-01-01

    Objective To estimate the impact of a national primary care pay for performance scheme, the Quality and Outcomes Framework in England, on emergency hospital admissions for ambulatory care sensitive conditions (ACSCs). Design Controlled longitudinal study. Setting English National Health Service between 1998/99 and 2010/11. Participants Populations registered with each of 6975 family practices in England. Main outcome measures Year specific differences between trend adjusted emergency hospital admission rates for incentivised ACSCs before and after the introduction of the Quality and Outcomes Framework scheme and two comparators: non-incentivised ACSCs and non-ACSCs. Results Incentivised ACSC admissions showed a relative reduction of 2.7% (95% confidence interval 1.6% to 3.8%) in the first year of the Quality and Outcomes Framework compared with ACSCs that were not incentivised. This increased to a relative reduction of 8.0% (6.9% to 9.1%) in 2010/11. Compared with conditions that are not regarded as being influenced by the quality of ambulatory care (non-ACSCs), incentivised ACSCs also showed a relative reduction in rates of emergency admissions of 2.8% (2.0% to 3.6%) in the first year increasing to 10.9% (10.1% to 11.7%) by 2010/11. Conclusions The introduction of a major national pay for performance scheme for primary care in England was associated with a decrease in emergency admissions for incentivised conditions compared with conditions that were not incentivised. Contemporaneous health service changes seem unlikely to have caused the sharp change in the trajectory of incentivised ACSC admissions immediately after the introduction of the Quality and Outcomes Framework. The decrease seems larger than would be expected from the changes in the process measures that were incentivised, suggesting that the pay for performance scheme may have had impacts on quality of care beyond the directly incentivised activities. PMID:25389120

  14. Evaluation of the Use of Home Blood Pressure Measurement Using Mobile Phone-Assisted Technology: The iVitality Proof-of-Principle Study.

    PubMed

    Wijsman, Liselotte W; Richard, Edo; Cachucho, Ricardo; de Craen, Anton Jm; Jongstra, Susan; Mooijaart, Simon P

    2016-06-13

    Mobile phone-assisted technologies provide the opportunity to optimize the feasibility of long-term blood pressure (BP) monitoring at home, with the potential of large-scale data collection. In this proof-of-principle study, we evaluated the feasibility of home BP monitoring using mobile phone-assisted technology, by investigating (1) the association between study center and home BP measurements; (2) adherence to reminders on the mobile phone to perform home BP measurements; and (3) referrals, treatment consequences and BP reduction after a raised home BP was diagnosed. We used iVitality, a research platform that comprises a Website, a mobile phone-based app, and health sensors, to measure BP and several other health characteristics during a 6-month period. BP was measured twice at baseline at the study center. Home BP was measured on 4 days during the first week, and thereafter, at semimonthly or monthly intervals, for which participants received reminders on their mobile phone. In the monthly protocol, measurements were performed during 2 consecutive days. In the semimonthly protocol, BP was measured at 1 day. We included 151 participants (mean age [standard deviation] 57.3 [5.3] years). BP measured at the study center was systematically higher when compared with home BP measurements (mean difference systolic BP [standard error] 8.72 [1.08] and diastolic BP 5.81 [0.68] mm Hg, respectively). Correlation of study center and home measurements of BP was high (R=0.72 for systolic BP and 0.72 for diastolic BP, both P<.001). Adherence was better in participants measuring semimonthly (71.4%) compared with participants performing monthly measurements (64.3%, P=.008). During the study, 41 (27.2%) participants were referred to their general practitioner because of a high BP. Referred participants had a decrease in their BP during follow-up (mean difference final and initial [standard error] -5.29 [1.92] for systolic BP and -2.93 [1.08] for diastolic BP, both P<.05). Mobile phone-assisted technology is a reliable and promising method with good adherence to measure BP at home during a 6-month period. This provides a possibility for implementation in large-scale studies and can potentially contribute to BP reduction.

  15. Venus gravity: Summary and coming events

    NASA Technical Reports Server (NTRS)

    Sjogren, W. L.

    1992-01-01

    The first significant dataset to provide local measures of venusian gravity field variations was that acquired from the Pioneer Venus Orbiter (PVO) during the 1979-1981 period. These observations were S-band Doppler radio signals from the orbiting spacecraft received at Earth-based tracking stations. Early reductions of these data were performed using two quite different techniques. Estimates of the classical spherical harmonics were made to various degrees and orders up to 10. At that time, solutions of much higher degree and order were very difficult due to computer limitations. These reductions, because of low degree and order, revealed only the most prominent features with poor spatial resolution and very reduced peak amplitudes.

  16. Review of noise reduction methods for centrifugal fans

    NASA Astrophysics Data System (ADS)

    Neise, W.

    1981-11-01

    Several methods for the reduction of centrifugal fan noise are presented, the most of which are aimed at a lower blade passage frequency level. The methods are grouped into five categories: casing modifications to increase the distance between impeller and cutoff, the introduction of a phase shift of the source pressure fluctuations, impeller modifications, radial clearance between impeller eye and inlet nozzle, and acoustical measures. Resonators mounted at the cutoff of centrifugal fans appear to be a highly efficient and simple means of reducing the blade passage tone, and the method can be used for new fan construction and existing installations without affecting the aerodynamic performance of the fan.

  17. Focused Ultrasound Lipolysis in the Treatment of Abdominal Cellulite: An Open-Label Study

    PubMed Central

    Moravvej, Hamideh; Akbari, Zahra; Mohammadian, Shahrzad; Razzaghi, Zahra

    2015-01-01

    Introduction: Despite a growing popularity of noninvasive ultrasonic lipolysis procedure, there is a lack of evidence about the efficacy of this method. This study was performed to evaluate the efficacy of focused ultrasonic lipolysis on abdominal cellulite treatment. Methods: Twenty-eight consecutive subjects (age: 37.8 ± 8 years) underwent weekly transdermal focused ultrasonic lipolysis (Med Contour, General Project Ltd., Florence, Italy) and vacuum drainage for a maximum of eight sessions. Largest abdominal girth and 2 lines at 4 cm to 7 cm distance above and under it were located as fixed points of measurements. The mean value of the three fixed lines was considered as the abdominal circumference. Subjects were evaluated using measurements of circumference, immediately after and 3 weeks after the final treatment and compared using paired t test. Results: One hundred ninety-four ultrasonic lipolysis procedures were performed on 28 subjects. A statistically significant (P < .001) average of 1.89 cm (95% CI: 1.63-2.02 cm) decrease of circumference value was observed in each session of ultrasonic lipolysis. The mean pretreatment to posttreatment circumference reduction was 8.21 cm (95% CI: 6.38-10.04, P < .001) that declined to 7 cm (95% CI: 3.2-10.8, P < .001) at the 3-month follow-up visit. Conclusion: Focused ultrasonic lipolysis appears to be an effective method for reduction of abdominal cellulite, although some amount of circumference reduction reversal may be observed in long term follow-up visit. PMID:26464776

  18. Hippocampal volume and memory performance in children with perinatal stroke.

    PubMed

    Gold, Jeffrey J; Trauner, Doris A

    2014-01-01

    Pediatric neurologists and neonatologists often are asked to predict cognitive outcome after perinatal brain injury (including likely memory and learning outcomes). However, relatively few data exist on how accurate predictions can be made. Furthermore, although the consequences of brain injury on hippocampal volume and memory performance have been studied extensively in adults, little work has been done in children. We measured the volume of the hippocampus in 27 children with perinatal stroke and 19 controls, and measured their performance on standardized verbal and non-verbal memory tests. We discovered the following: (1) As a group, children with perinatal stroke had smaller left and right hippocampi compared with control children. (2) Individually, children with perinatal stroke demonstrated 1 of 3 findings: no hippocampal loss, unilateral hippocampal loss, or bilateral hippocampal volume loss compared with control children. (3) Hippocampal volume inversely correlated with memory test performance in the perinatal stroke group, with smaller left and right hippocampal volumes related to poorer verbal and non-verbal memory test performance, respectively. (4) Seizures played a significant role in determining memory deficit and extent of hippocampal volume reduction in patients with perinatal stroke. These findings support the view that, in the developing brain, the left and right hippocampi preferentially support verbal and nonverbal memory respectively, a consistent finding in the adult literature but a subject of debate in the pediatric literature. This is the first work to report that children with focal brain injury incurred from perinatal stroke have volume reduction in the hippocampus and impairments in certain aspects of declarative memory. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Three-dimensional MRI Analysis of Femoral Head Remodeling After Reduction in Patients With Developmental Dysplasia of the Hip.

    PubMed

    Tsukagoshi, Yuta; Kamada, Hiroshi; Kamegaya, Makoto; Takeuchi, Ryoko; Nakagawa, Shogo; Tomaru, Yohei; Tanaka, Kenta; Onishi, Mio; Nishino, Tomofumi; Yamazaki, Masashi

    2018-05-02

    Previous reports on patients with developmental dysplasia of the hip (DDH) showed that the prereduced femoral head was notably smaller and more nonspherical than the intact head, with growth failure observed at the proximal posteromedial area. We evaluated the shape of the femoral head cartilage in patients with DDH before and after reduction, with size and sphericity assessed using 3-dimensional (3D) magnetic resonance imaging (MRI). We studied 10 patients with unilateral DDH (all female) who underwent closed reduction. Patients with avascular necrosis of the femoral head on the plain radiograph 1 year after reduction were excluded. 3D MRI was performed before reduction and after reduction, at 2 years of age. 3D-image analysis software was used to reconstruct the multiplanes. After setting the axial, coronal, and sagittal planes in the software (based on the femoral shaft and neck axes), the smallest sphere that included the femoral head cartilage was drawn, the diameter was measured, and the center of the sphere was defined as the femoral head center. We measured the distance between the center and cartilage surface every 30 degrees on the 3 reconstructed planes. Sphericity of the femoral head was calculated using a ratio (the distance divided by each radius) and compared between prereduction and postreduction. The mean patient age was 7±3 and 26±3 months at the first and second MRI, respectively. The mean duration between the reduction and second MRI was 18±3 months. The femoral head diameter was 26.7±1.5 and 26.0±1.6 mm on the diseased and intact sides, respectively (P=0.069). The ratios of the posteromedial area on the axial plane and the proximoposterior area on the sagittal plane after reduction were significantly larger than before reduction (P<0.01). We demonstrated that the size of the reduced femoral head was nearly equal to that of the intact femoral head and that the growth failure area of the head before reduction, in the proximal posteromedial area, was remodeled after reduction. Level IV-case series.

  20. Induced senescence promotes the feeding activities and nymph development of Myzus persicae (Hemiptera: Aphididae) on potato plants.

    PubMed

    Machado-Assefh, Cristina R; Lucatti, Alejandro F; Alvarez, Adriana E

    2014-01-01

    The effect of dark-induced senescence on Solanum tuberosum L. (Solanales: Solanaceae) plants was assessed on the feeding behavior and performance of the green peach aphid, Myzus persicae Sulzer (Hemiptera: Aphididae). Senescence was induced by covering the basal part of the plant with a black cloth for 5 d, avoiding the light passage, but keeping the apical buds uncovered. The basal part of control plants was covered with a white nonwoven cloth. The degree of senescence was determined by measuring the chlorophyll content of the covered leaves. The performance and feeding behavior of M. persicae were studied on the uncovered nonsenescent apical leaves. The aphid's performance was evaluated by measuring nymphal mortality and prereproductive time. Aphid feeding behavior was monitored by the electrical penetration graph technique. In plants with dark-induced senescence, the aphids showed a reduction in their prereproductive time. Aphids also spent more time ingesting sap from the phloem than in control plants and performed more test probes after the first sustained ingestion of phloem sap. These data suggest that M. persicae's phloem activities and nymph development benefit from the nutritional enrichment of phloem sap, derived from dark-induced senescence on potato plants. The induced senescence improved plant acceptance by M. persicae through an increase in sap ingestion that likely resulted in a reduction in developmental time. © The Author 2014. Published by Oxford University Press on behalf of the Entomological Society of America.

  1. Study of clamping-induced deformations on SR optics by means of LTP

    NASA Astrophysics Data System (ADS)

    Cocco, Daniele; Sostero, Giovanni; Zangrando, Marco

    2001-01-01

    With the advent of third generation synchrotron radiation sources, more flux was available for the experimentalist. At the same time, the request in term of spot dimension and energy resolution rapidly increased. For this reason, opticians try to design beamlines with higher and higher performances. To this end the shape of every optical component of a beamline is specified to have very tight constrains, because every small figure error produces a sudden reduction in terms of the overall performance. Nevertheless, the necessity to positioning and cooling the components implies the presence of a safe clamping system which unavoidably would modifies the shape of the component, causing possible reduction of resolving power or increasing the spot dimension. Thus it is not sufficient to measure accurately the slope or the profile of a mirror in laboratory before the mounting, but it is useful to test it also after this procedure. We, at ELETTRA, have measured by means of a modified version of the LTP II (Long Trace Profiler) several mirrors and gratings before and after their clamping, in order to estimate the effect of the holder on the final performances of the beamlines. Since our LTP II measures directly the local slope of the surface under test with a repeatability better than 0.02 arcsec on a 1 meter long optical surface, it is very easy to single out any small distortion of the tangential profile introduced by the mounting system. Different kinds of supports for both small and large optical elements, were taken into consideration and the effect of the deformation induced by them on the beamline performance was simulated and will be presented here together with the results of each measurements. The results give us a way to select properly the kind of clamping and invite the opticians to try to take into consideration also this effect before designing a complex beamline.

  2. The healing effect of electrolytic-reduction ion water on burn wounds.

    PubMed

    Okajima, Masahiro; Shimokawa, Ken-ichi; Ishii, Fumiyoshi

    2010-02-01

    We prepared a lotion using electrolytic-reduction ion water (ERI), and evaluated the healing effects of this lotion (ERI lotion) on burn wounds. Third degree burn wounds were induced in the mouse dorsal skin, and ERI lotion or physiological salt (PS) lotion was applied to the wounds from immediately after injury [ERI (+) group and ERI (-) group as a control group, respectively]. The burn wound area was measured, and its serial changes were evaluated. In addition, histological examination of the burn wound site (on day 3) was performed. Comparison of the ERI (+) and (-) groups showed a significant reduction in the burn wound area in the former. Histological examination confirmed many interstitial spaces, blood vessels, and lymphatic vessels in the subcutaneous tissue in the ERI (-) compared with the ERI (+) group. These results suggest the promotion of burn wound healing by ERI lotion.

  3. Do microbial exudates control EH electrode measurements?

    NASA Astrophysics Data System (ADS)

    Markelova, E.; Parsons, C. T.; Smeaton, C. M.; Van Cappellen, P.

    2017-12-01

    Redox electrodes are widely used as simple, inexpensive monitoring devices to rapidly measure redox potentials (EH) of waterlogged soils, sediments, and aquifers. While a variety of physicochemical and biogeochemical factors have been involved to explain measured EH values, the role of microorganisms remains comparatively understudied and uncertain. Besides catalyzing many inorganic redox reactions (e.g., nitrate reduction), microorganisms produce a variety of redox-active organic compounds (e.g., NAD+/NADH, GSSG/2GSH, FAD/FADH2), which can be released into the surrounding environment via active secretion, passive diffusion, or cell lysis. To isolate different microbial effects on EH measurements, we performed batch experiments using S. oneidensis MR-I as a model heterotrophic microorganism and flavins as example microbial exudates [1]. We monitored EH and pH along with flavin production (fluorescence measurements) during dissimilatory nitrate reduction to ammonium (DNRA). Dissolved flavins increased to 0.2 mM (riboflavin equivalent) under anoxic conditions during complete consumption of 1 mM nitrate by DNRA at pH 7.4 and 30 °C over 80 hours. The observed redox cascade from +255 to -250 mV did not follow the EH predicted for the reduction of NO3- to NO2- and NO2- to NH4+ by the Nernst equation. However, a set of separate abiotic experiments on the photoreduction of synthetic flavins (LMC, RF, FMN, and FAD, Sigma Aldrich) under the same conditions indicated that measured EH values are buffered at +270 ± 20 mV and -230 ± 50 mV when oxidized and reduced flavin species dominate, respectively. Moreover, based on the temporal changes in EH, we speculate that NO3- reduction by S. oneidensis consumes reduced flavins (i.e., NO3- accepts electrons from reduced flavins) and generates oxidized flavins, thus buffering EH at +255 mV. By contrast, NO2- reduction to NH4+ is independent of flavin speciation, which leads to the accumulation of reduced flavins in the solution and lowering of EH to -250 mV. Overall, the experiments demonstrate that microbial exudates do affect EH measurements, however, their importance in natural water-saturated systems has to be further evaluated. [1] Von Canstein, H., et al., 2008. Appl. Environ. Microbiol. 74, 615-623.

  4. SU-E-T-774: Use of a Scintillator-Mirror-Camera System for the Measurement of MLC Leakage Radiation with the CyberKnife M6 System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goggin, L; Kilby, W; Noll, M

    2015-06-15

    Purpose: A technique using a scintillator-mirror-camera system to measure MLC leakage was developed to provide an efficient alternative to film dosimetry while maintaining high spatial resolution. This work describes the technique together with measurement uncertainties. Methods: Leakage measurements were made for the InCise™ MLC using the Logos XRV-2020A device. For each measurement approximately 170 leakage and background images were acquired using optimized camera settings. Average background was subtracted from each leakage frame before filtering the integrated leakage image to replace anomalous pixels. Pixel value to dose conversion was performed using a calibration image. Mean leakage was calculated within an ROImore » corresponding to the primary beam, and maximum leakage was determined by binning the image into overlapping 1mm x 1mm ROIs. 48 measurements were performed using 3 cameras and multiple MLC-linac combinations in varying beam orientations, with each compared to film dosimetry. Optical and environmental influences were also investigated. Results: Measurement time with the XRV-2020A was 8 minutes vs. 50 minutes using radiochromic film, and results were available immediately. Camera radiation exposure degraded measurement accuracy. With a relatively undamaged camera, mean leakage agreed with film measurement to ≤0.02% in 92% cases, ≤0.03% in 100% (for maximum leakage the values were 88% and 96%) relative to reference open field dose. The estimated camera lifetime over which this agreement is maintained is at least 150 measurements, and can be monitored using reference field exposures. A dependency on camera temperature was identified and a reduction in sensitivity with distance from image center due to optical distortion was characterized. Conclusion: With periodic monitoring of the degree of camera radiation damage, the XRV-2020A system can be used to measure MLC leakage. This represents a significant time saving when compared to the traditional film-based approach without any substantial reduction in accuracy.« less

  5. Capturing the dynamics of response variability in the brain in ADHD.

    PubMed

    van Belle, Janna; van Raalten, Tamar; Bos, Dienke J; Zandbelt, Bram B; Oranje, Bob; Durston, Sarah

    2015-01-01

    ADHD is characterized by increased intra-individual variability in response times during the performance of cognitive tasks. However, little is known about developmental changes in intra-individual variability, and how these changes relate to cognitive performance. Twenty subjects with ADHD aged 7-24 years and 20 age-matched, typically developing controls participated in an fMRI-scan while they performed a go-no-go task. We fit an ex-Gaussian distribution on the response distribution to objectively separate extremely slow responses, related to lapses of attention, from variability on fast responses. We assessed developmental changes in these intra-individual variability measures, and investigated their relation to no-go performance. Results show that the ex-Gaussian measures were better predictors of no-go performance than traditional measures of reaction time. Furthermore, we found between-group differences in the change in ex-Gaussian parameters with age, and their relation to task performance: subjects with ADHD showed age-related decreases in their variability on fast responses (sigma), but not in lapses of attention (tau), whereas control subjects showed a decrease in both measures of variability. For control subjects, but not subjects with ADHD, this age-related reduction in variability was predictive of task performance. This group difference was reflected in neural activation: for typically developing subjects, the age-related decrease in intra-individual variability on fast responses (sigma) predicted activity in the dorsal anterior cingulate gyrus (dACG), whereas for subjects with ADHD, activity in this region was related to improved no-go performance with age, but not to intra-individual variability. These data show that using more sophisticated measures of intra-individual variability allows the capturing of the dynamics of task performance and associated neural changes not permitted by more traditional measures.

  6. Capturing the dynamics of response variability in the brain in ADHD

    PubMed Central

    van Belle, Janna; van Raalten, Tamar; Bos, Dienke J.; Zandbelt, Bram B.; Oranje, Bob; Durston, Sarah

    2014-01-01

    ADHD is characterized by increased intra-individual variability in response times during the performance of cognitive tasks. However, little is known about developmental changes in intra-individual variability, and how these changes relate to cognitive performance. Twenty subjects with ADHD aged 7–24 years and 20 age-matched, typically developing controls participated in an fMRI-scan while they performed a go-no-go task. We fit an ex-Gaussian distribution on the response distribution to objectively separate extremely slow responses, related to lapses of attention, from variability on fast responses. We assessed developmental changes in these intra-individual variability measures, and investigated their relation to no-go performance. Results show that the ex-Gaussian measures were better predictors of no-go performance than traditional measures of reaction time. Furthermore, we found between-group differences in the change in ex-Gaussian parameters with age, and their relation to task performance: subjects with ADHD showed age-related decreases in their variability on fast responses (sigma), but not in lapses of attention (tau), whereas control subjects showed a decrease in both measures of variability. For control subjects, but not subjects with ADHD, this age-related reduction in variability was predictive of task performance. This group difference was reflected in neural activation: for typically developing subjects, the age-related decrease in intra-individual variability on fast responses (sigma) predicted activity in the dorsal anterior cingulate gyrus (dACG), whereas for subjects with ADHD, activity in this region was related to improved no-go performance with age, but not to intra-individual variability. These data show that using more sophisticated measures of intra-individual variability allows the capturing of the dynamics of task performance and associated neural changes not permitted by more traditional measures. PMID:25610775

  7. Longitudinal relationships among posturography and gait measures in multiple sclerosis.

    PubMed

    Fritz, Nora E; Newsome, Scott D; Eloyan, Ani; Marasigan, Rhul Evans R; Calabresi, Peter A; Zackowski, Kathleen M

    2015-05-19

    Gait and balance dysfunction frequently occurs early in the multiple sclerosis (MS) disease course. Hence, we sought to determine the longitudinal relationships among quantitative measures of gait and balance in individuals with MS. Fifty-seven ambulatory individuals with MS (28 relapsing-remitting, 29 progressive) were evaluated using posturography, quantitative sensorimotor and gait measures, and overall MS disability with the Expanded Disability Status Scale at each session. Our cohort's age was 45.8 ± 10.4 years (mean ± SD), follow-up time 32.8 ± 15.4 months, median Expanded Disability Status Scale score 3.5, and 56% were women. Poorer performance on balance measures was related to slower walking velocity. Two posturography measures, the anterior-posterior sway and sway during static eyes open, feet apart conditions, were significant contributors to walk velocity over time (approximate R(2) = 0.95), such that poorer performance on the posturography measures was related to slower walking velocity. Similarly, the anterior-posterior sway and sway during static eyes closed, feet together conditions were also significant contributors to the Timed 25-Foot Walk performance over time (approximate R(2) = 0.83). This longitudinal cohort study establishes a strong relationship between clinical gait measures and posturography. The data show that increases in static posturography and reductions in dynamic posturography are associated with a decline in walk velocity and Timed 25-Foot Walk performance over time. Furthermore, longitudinal balance measures predict future walking performance. Quantitative walking and balance measures are important additions to clinical testing to explore longitudinal change and understand fall risk in this progressive disease population. © 2015 American Academy of Neurology.

  8. Pressure dependence of the oxygen reduction reaction at the platinum microelectrode/nafion interface - Electrode kinetics and mass transport

    NASA Technical Reports Server (NTRS)

    Parthasarathy, Arvind; Srinivasan, Supramaniam; Appleby, A. J.; Martin, Charles R.

    1992-01-01

    The investigation of oxygen reduction kinetics at the platinum/Nafion interface is of great importance in the advancement of proton-exchange-membrane (PEM) fuel-cell technology. This study focuses on the dependence of the oxygen reduction kinetics on oxygen pressure. Conventional Tafel analysis of the data shows that the reaction order with respect to oxygen is unity at both high and low current densities. Chronoamperometric measurements of the transport parameters for oxygen in Nafion show that oxygen dissolution follows Henry's isotherm. The diffusion coefficient of oxygen is invariant with pressure; however, the diffusion coefficient for oxygen is lower when air is used as the equilibrating gas as compared to when oxygen is used for equilibration. These results are of value in understanding the influence of O2 partial pressure on the performance of PEM fuel cells and also in elucidating the mechanism of oxygen reduction at the platinum/Nafion interface.

  9. Conceptual design of a data reduction system

    NASA Technical Reports Server (NTRS)

    1983-01-01

    A telemetry data processing system was defined of the Data Reduction. Data reduction activities in support of the developmental flights of the Space Shuttle were used as references against which requirements are assessed in general terms. A conceptual system design believed to offer significant throughput for the anticipated types of data reduction activities is presented. The design identifies the use of a large, intermediate data store as a key element in a complex of high speed, single purpose processors, each of which performs predesignated, repetitive operations on either raw or partially processed data. The recommended approach to implement the design concept is to adopt an established interface standard and rely heavily on mature or promising technologies which are considered main stream of the integrated circuit industry. The design system concept, is believed to be implementable without reliance on exotic devices and/or operational procedures. Numerical methods were employed to examine the feasibility of digital discrimination of FDM composite signals, and of eliminating line frequency noises in data measurements.

  10. In situ measurements of dissolved oxygen, pH and redox potential of biocathode microenvironments using microelectrodes.

    PubMed

    Wang, Zejie; Deng, Huan; Chen, Lihui; Xiao, Yong; Zhao, Feng

    2013-03-01

    Biofilms are the core component of bioelectrochemical systems (BESs). To understand the polarization effects on biocathode performance of BES, dissolved oxygen concentrations, pHs and oxidation-reduction potentials of biofilm microenvironments were determined in situ. The results showed that lower polarization potentials resulted in the generation of larger currents and higher pH values, as well as the consumption of more oxygen. Oxidation-reduction potentials of biofilms were mainly affected by polarization potentials of the electrode rather than the concentration of dissolved oxygen or pH value, and its changes in the potentials corresponded to the electric field distribution of the electrode surface. The results demonstrated that a sufficient supply of dissolved oxygen and pH control of the biocathode are necessary to obtain optimal performance of BESs; a lower polarization potential endowed microorganisms with a higher electrochemical activity. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. Wingtip vortex turbine investigation for vortex energy recovery

    NASA Technical Reports Server (NTRS)

    Abeyounis, William K.; Patterson, James C., Jr.; Stough, H. P., III; Wunschel, Alfred J.; Curran, Patrick D.

    1990-01-01

    A flight test investigation has been conducted to determine the performance of wingtip vortex turbines and their effect on aircraft performance. The turbines were designed to recover part of the large energy loss (induced drag) caused by the wingtip vortex. The turbine, driven by the vortex flow, reduces the strength of the vortex, resulting in an associated induced drag reduction. A four-blade turbine was mounted on each wingtip of a single-engine, T-tail, general aviation airplane. Two sets of turbine blades were tested, one with a 15' twist (washin) and one with no twist. Th power recovered by the turbine and the installed drag increment were measured. A trade-off between turbine power and induced drag reduction was found to be a function of turbine blade incidence angle. This test has demonstrated that the wingtip vortex turbine is an attractive alternate, as well as an emergency, power source.

  12. Orthopaedic traumatology: fundamental principles and current controversies for the acute care surgeon

    PubMed Central

    Pharaon, Shad K; Schoch, Shawn; Marchand, Lucas; Mirza, Amer

    2018-01-01

    Multiply injured patients with fractures are co-managed by acute care surgeons and orthopaedic surgeons. In most centers, orthopaedic surgeons definitively manage fractures, but preliminary management, including washouts, splinting, reductions, and external fixations, may be performed by selected acute care surgeons. The acute care surgeon should have a working knowledge of orthopaedic terminology to communicate with colleagues effectively. They should have an understanding of the composition of bone, periosteum, and cartilage, and their reaction when there is an injury. Fractures are usually fixed urgently, but some multiply injured patients are better served with a damage control strategy. Extremity compartment syndrome should be suspected in all critically injured patients with or without fractures and a low threshold for compartment pressure measurements or empiric fasciotomy maintained. Acute care surgeons performing rib fracture fixation and other chest wall injury reconstructions should follow the principles of open fracture reduction and stabilization. PMID:29766123

  13. Orthopaedic traumatology: fundamental principles and current controversies for the acute care surgeon.

    PubMed

    Pharaon, Shad K; Schoch, Shawn; Marchand, Lucas; Mirza, Amer; Mayberry, John

    2018-01-01

    Multiply injured patients with fractures are co-managed by acute care surgeons and orthopaedic surgeons. In most centers, orthopaedic surgeons definitively manage fractures, but preliminary management, including washouts, splinting, reductions, and external fixations, may be performed by selected acute care surgeons. The acute care surgeon should have a working knowledge of orthopaedic terminology to communicate with colleagues effectively. They should have an understanding of the composition of bone, periosteum, and cartilage, and their reaction when there is an injury. Fractures are usually fixed urgently, but some multiply injured patients are better served with a damage control strategy. Extremity compartment syndrome should be suspected in all critically injured patients with or without fractures and a low threshold for compartment pressure measurements or empiric fasciotomy maintained. Acute care surgeons performing rib fracture fixation and other chest wall injury reconstructions should follow the principles of open fracture reduction and stabilization.

  14. Research on PM2.5 emission reduction path of China ‘s electric power industry based on DEA model

    NASA Astrophysics Data System (ADS)

    Jin, Yanming; Yang, Fan; Liu, Jun

    2018-02-01

    Based on the theory of data envelopment analysis, this study constructs the environmental performance evaluation model of the power industry, analyzes the performance of development of clean energy, the implementation of electricity replacement, and the development of coal-fired energy-saving and emission-reducing measures. Put forward technology path to reduce emission in the future. The results show that (1) improving the proportion of coal for power generation, speeding up the replacement of electricity is the key to solve the haze in China. (2) With the photovoltaic and other new energy power generation costs gradually reduced and less limit from thermal energy, by final of “thirteenth five-years plan”, the economy of clean energy will surpass thermal energy-saving emission reduction. (3) After 2025, the economy of the electricity replacement will be able to show.

  15. An Assessment of Flap and Main Landing Gear Noise Abatement Concepts

    NASA Technical Reports Server (NTRS)

    Khorrami, Mehdi R.; Humphreys, William M., Jr.; Lockard, David P.

    2015-01-01

    A detailed assessment of the acoustic performance of several noise reduction concepts for aircraft flaps and landing gear is presented. Consideration is given to the best performing concepts within the suite of technologies that were evaluated in the NASA Langley Research Center 14- by 22-Foot Subsonic Tunnel using an 18 percent scale, semi-span, high-fidelity Gulfstream aircraft model as a test bed. Microphone array measurements were obtained with the model in a landing configuration (flap deflected 39 degrees and the main landing gear deployed or retracted). The effectiveness of each concept over the range of pitch angles, speeds, and directivity angles tested is presented. Comparison of the acoustic spectra, obtained from integration of the beamform maps between the untreated baseline and treated configurations, clearly demonstrates that the flap and gear concepts maintain noise reduction benefits over the entire range of the directivity angles tested.

  16. Structural and Acoustic Damping Characteristics of Polyimide Microspheres

    NASA Technical Reports Server (NTRS)

    Palumbo, Daniel L.; Park, Junhong

    2005-01-01

    A broad range of tests have been performed to evaluate the capability of tiny lightweight polyimide spheres to reduce sound and vibration. The types of testing includes impedance tube measurement of propagation constant, sound power insertion loss for single and double wall systems, particle frame wave characterization and beam vibration reduction. The tests were performed using spheres made of two types of polyimide and with varying diameter. Baseline results were established using common noise reduction treatment materials such as fiberglass and foam. The spheres were difficult to test due to their inherent mobility. Most tests required some adaptation to contain the spheres. One test returned obvious non-linear behavior, a result which has come to be expected for treatments of this type. The polyimide spheres are found to be a competent treatment for both sound and vibration energy with the reservation that more work needs to be done to better characterize the non-linear behavior.

  17. Computational Modeling of a Mechanized Benchtop Apparatus for Leading-Edge Slat Noise Treatment Device Prototypes

    NASA Technical Reports Server (NTRS)

    Turner, Travis L.; Moore, James B.; Long, David L.

    2017-01-01

    Airframe noise is a growing concern in the vicinity of airports because of population growth and gains in engine noise reduction that have rendered the airframe an equal contributor during the approach and landing phases of flight for many transport aircraft. The leading-edge-slat device of a typical high-lift system for transport aircraft is a prominent source of airframe noise. Two technologies have significant potential for slat noise reduction; the slat-cove filler (SCF) and the slat-gap filler (SGF). Previous work was done on a 2D section of a transport-aircraft wing to demonstrate the implementation feasibility of these concepts. Benchtop hardware was developed in that work for qualitative parametric study. The benchtop models were mechanized for quantitative measurements of performance. Computational models of the mechanized benchtop apparatus for the SCF were developed and the performance of the system for five different SCF assemblies is demonstrated.

  18. Experimental assessment of the performance of ablative heat shield materials from plasma wind tunnel testing

    NASA Astrophysics Data System (ADS)

    Löhle, S.; Hermann, T.; Zander, F.

    2017-12-01

    A method for assessing the performance of typical heat shield materials is presented in this paper. Three different material samples, the DLR material uc(Zuram), the Airbus material uc(Asterm) and the carbon preform uc(Calcarb) were tested in the IRS plasma wind tunnel PWK1 at the same nominal condition. State of the art diagnostic tools, i.e., surface temperature with pyrometry and thermography and boundary layer optical emission spectroscopy were completed by photogrammetric surface recession measurements. These data allow the assessment of the net heat flux for each material. The analysis shows that the three materials each have a different effect on heat flux mitigation with ASTERM showing the largest reduction in surface heat flux. The effect of pyrolysis and blowing is clearly observed and the heat flux reduction can be determined from an energy balance.

  19. Effects of interstage diffuser flow distortion on the performance of a 15.41-centimeter tip diameter axial power turbine

    NASA Technical Reports Server (NTRS)

    Mclallin, K. L.; Kofskey, M. G.; Civinskas, K. C.

    1983-01-01

    The performance of a variable-area stator, axial flow power turbine was determined in a cold-air component research rig for two inlet duct configurations. The two ducts were an interstage diffuser duct and an accelerated-flow inlet duct which produced stator inlet boundary layer flow blockages of 11 percent and 3 percent, respectively. Turbine blade total efficiency at design point was measured to be 5.3 percent greater with the accelerated-flow inlet duct installed due to the reduction in inlet blockage. Blade component measurements show that of this performance improvement, 35 percent occurred in the stator and 65 percent occurred in the rotor. Analysis of inlet duct internal flow using an Axisymmetric Diffuser Duct Code (ADD Code) were in substantial agreement with the test data.

  20. Study on signal intensity of low field nuclear magnetic resonance via an indirect coupling measurement

    NASA Astrophysics Data System (ADS)

    Jiang, Feng-Ying; Wang, Ning; Jin, Yi-Rong; Deng, Hui; Tian, Ye; Lang, Pei-Lin; Li, Jie; Chen, Ying-Fei; Zheng, Dong-Ning

    2013-04-01

    We carry out an ultra-low-field nuclear magnetic resonance (NMR) experiment based on high-Tc superconducting quantum interference devices (SQUIDs). The measurement field is in a micro-tesla range (~10 μT-100 μT) and the experiment is conducted in a home-made magnetically-shielded-room (MSR). The measurements are performed by the indirect coupling method in which the signal of nuclei precession is indirectly coupled to the SQUID through a tuned copper coil transformer. In such an arrangement, the interferences of applied measurement and polarization field to the SQUID sensor are avoided and the performance of the SQUID is not destroyed. In order to compare the detection sensitivity obtained by using the SQUID with that achieved using a conventional low-noise-amplifier, we perform the measurements using a commercial room temperature amplifier. The results show that in a wide frequency range (~1 kHz-10 kHz) the measurements with the SQUID sensor exhibit a higher signal-to-noise ratio. Further, we discuss the dependence of NMR peak magnitude on measurement frequency. We attribute the reduction of the peak magnitude at high frequency to the increased field inhomogeneity as the measurement field increases. This is verified by compensating the field gradient using three sets of gradient coils.

  1. A proposed standard method for polarimetric calibration and calibration verification

    NASA Astrophysics Data System (ADS)

    Persons, Christopher M.; Jones, Michael W.; Farlow, Craig A.; Morell, L. Denise; Gulley, Michael G.; Spradley, Kevin D.

    2007-09-01

    Accurate calibration of polarimetric sensors is critical to reducing and analyzing phenomenology data, producing uniform polarimetric imagery for deployable sensors, and ensuring predictable performance of polarimetric algorithms. It is desirable to develop a standard calibration method, including verification reporting, in order to increase credibility with customers and foster communication and understanding within the polarimetric community. This paper seeks to facilitate discussions within the community on arriving at such standards. Both the calibration and verification methods presented here are performed easily with common polarimetric equipment, and are applicable to visible and infrared systems with either partial Stokes or full Stokes sensitivity. The calibration procedure has been used on infrared and visible polarimetric imagers over a six year period, and resulting imagery has been presented previously at conferences and workshops. The proposed calibration method involves the familiar calculation of the polarimetric data reduction matrix by measuring the polarimeter's response to a set of input Stokes vectors. With this method, however, linear combinations of Stokes vectors are used to generate highly accurate input states. This allows the direct measurement of all system effects, in contrast with fitting modeled calibration parameters to measured data. This direct measurement of the data reduction matrix allows higher order effects that are difficult to model to be discovered and corrected for in calibration. This paper begins with a detailed tutorial on the proposed calibration and verification reporting methods. Example results are then presented for a LWIR rotating half-wave retarder polarimeter.

  2. Study the performance of star sensor influenced by space radiation damage of image sensor

    NASA Astrophysics Data System (ADS)

    Feng, Jie; Li, Yudong; Wen, Lin; Guo, Qi; Zhang, Xingyao

    2018-03-01

    Star sensor is an essential component of spacecraft attitude control system. Spatial radiation can cause star sensor performance degradation, abnormal work, attitude measurement accuracy and reliability reduction. Many studies have already been dedicated to the radiation effect on Charge-Coupled Device(CCD) image sensor, but fewer studies focus on the radiation effect of star sensor. The innovation of this paper is to study the radiation effects from the device level to the system level. The influence of the degradation of CCD image sensor radiation sensitive parameters on the performance parameters of star sensor is studied in this paper. The correlation among the radiation effect of proton, the non-uniformity noise of CCD image sensor and the performance parameter of star sensor is analyzed. This paper establishes a foundation for the study of error prediction and correction technology of star sensor on-orbit attitude measurement, and provides some theoretical basis for the design of high performance star sensor.

  3. Performance enhancement of low-cost, high-accuracy, state estimation for vehicle collision prevention system using ANFIS

    NASA Astrophysics Data System (ADS)

    Saadeddin, Kamal; Abdel-Hafez, Mamoun F.; Jaradat, Mohammad A.; Jarrah, Mohammad Amin

    2013-12-01

    In this paper, a low-cost navigation system that fuses the measurements of the inertial navigation system (INS) and the global positioning system (GPS) receiver is developed. First, the system's dynamics are obtained based on a vehicle's kinematic model. Second, the INS and GPS measurements are fused using an extended Kalman filter (EKF) approach. Subsequently, an artificial intelligence based approach for the fusion of INS/GPS measurements is developed based on an Input-Delayed Adaptive Neuro-Fuzzy Inference System (IDANFIS). Experimental tests are conducted to demonstrate the performance of the two sensor fusion approaches. It is found that the use of the proposed IDANFIS approach achieves a reduction in the integration development time and an improvement in the estimation accuracy of the vehicle's position and velocity compared to the EKF based approach.

  4. Sequential Blood Filtration for Extracorporeal Circulation: Initial Results from a Proof-of-Concept Prototype.

    PubMed

    Herbst, Daniel P

    2014-09-01

    Micropore filters are used during extracorporeal circulation to prevent gaseous and solid particles from entering the patient's systemic circulation. Although these devices improve patient safety, limitations in current designs have prompted the development of a new concept in micropore filtration. A prototype of the new design was made using 40-μm filter screens and compared against four commercially available filters for performance in pressure loss and gross air handling. Pre- and postfilter bubble counts for 5- and 10-mL bolus injections in an ex vivo test circuit were recorded using a Doppler ultrasound bubble counter. Statistical analysis of results for bubble volume reduction between test filters was performed with one-way repeated-measures analysis of variance using Bonferroni post hoc tests. Changes in filter performance with changes in microbubble load were also assessed with dependent t tests using the 5- and 10-mL bolus injections as the paired sample for each filter. Significance was set at p < .05. All filters in the test group were comparable in pressure loss performance, showing a range of 26-33 mmHg at a flow rate of 6 L/min. In gross air-handling studies, the prototype showed improved bubble volume reduction, reaching statistical significance with three of the four commercial filters. All test filters showed decreased performance in bubble volume reduction when the microbubble load was increased. Findings from this research support the underpinning theories of a sequential arterial-line filter design and suggest that improvements in microbubble filtration may be possible using this technique.

  5. Sequential Blood Filtration for Extracorporeal Circulation: Initial Results from a Proof-of-Concept Prototype

    PubMed Central

    Herbst, Daniel P.

    2014-01-01

    Abstract: Micropore filters are used during extracorporeal circulation to prevent gaseous and solid particles from entering the patient’s systemic circulation. Although these devices improve patient safety, limitations in current designs have prompted the development of a new concept in micropore filtration. A prototype of the new design was made using 40-μm filter screens and compared against four commercially available filters for performance in pressure loss and gross air handling. Pre- and postfilter bubble counts for 5- and 10-mL bolus injections in an ex vivo test circuit were recorded using a Doppler ultrasound bubble counter. Statistical analysis of results for bubble volume reduction between test filters was performed with one-way repeated-measures analysis of variance using Bonferroni post hoc tests. Changes in filter performance with changes in microbubble load were also assessed with dependent t tests using the 5- and 10-mL bolus injections as the paired sample for each filter. Significance was set at p < .05. All filters in the test group were comparable in pressure loss performance, showing a range of 26–33 mmHg at a flow rate of 6 L/min. In gross air-handling studies, the prototype showed improved bubble volume reduction, reaching statistical significance with three of the four commercial filters. All test filters showed decreased performance in bubble volume reduction when the microbubble load was increased. Findings from this research support the underpinning theories of a sequential arterial-line filter design and suggest that improvements in microbubble filtration may be possible using this technique. PMID:26357790

  6. Reducing sedation time for thyroplasty with arytenoid adduction with sequential anesthetic technique.

    PubMed

    Saadeh, Charles K; Rosero, Eric B; Joshi, Girish P; Ozayar, Esra; Mau, Ted

    2017-12-01

    To determine the extent to which a sequential anesthetic technique 1) shortens time under sedation for thyroplasty with arytenoid adduction (TP-AA), 2) affects the total operative time, and 3) changes the voice outcome compared to TP-AA performed entirely under sedation/analgesia. Case-control study. A new sequential anesthetic technique of performing most of the TP-AA surgery under general anesthesia (GA), followed by transition to sedation/analgesia (SA) for voice assessment, was developed to achieve smooth emergence from GA. Twenty-five TP-AA cases performed with the sequential GA-SA technique were compared with 25 TP-AA controls performed completely under sedation/analgesia. The primary outcome measure was the time under sedation. Voice improvement, as assessed by Consensus Auditory-Perceptual Evaluation of Voice, and total operative time were secondary outcome measures. With the conventional all-SA anesthetic, the duration of SA was 209 ± 26.3 minutes. With the sequential GA-SA technique, the duration of SA was 79.0 ± 18.9 minutes, a 62.3% reduction (P < 0.0001). There was no significant difference in the total operative time (209.5 vs. 200.9 minutes; P = 0.42) or in voice outcome. This sequential anesthetic technique has been easily adopted by multiple anesthesiologists and nurse anesthetists at our institution. TP-AA is effectively performed under sequential GA-SA technique with a significant reduction in the duration of time under sedation. This allows the surgeon to perform the technically more challenging part of the surgery under GA, without having to contend with variability in patient tolerance for laryngeal manipulation under sedation. 3b. Laryngoscope, 127:2813-2817, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  7. Plant species and functional group combinations affect green roof ecosystem functions.

    PubMed

    Lundholm, Jeremy; Macivor, J Scott; Macdougall, Zachary; Ranalli, Melissa

    2010-03-12

    Green roofs perform ecosystem services such as summer roof temperature reduction and stormwater capture that directly contribute to lower building energy use and potential economic savings. These services are in turn related to ecosystem functions performed by the vegetation layer such as radiation reflection and transpiration, but little work has examined the role of plant species composition and diversity in improving these functions. We used a replicated modular extensive (shallow growing- medium) green roof system planted with monocultures or mixtures containing one, three or five life-forms, to quantify two ecosystem services: summer roof cooling and water capture. We also measured the related ecosystem properties/processes of albedo, evapotranspiration, and the mean and temporal variability of aboveground biomass over four months. Mixtures containing three or five life-form groups, simultaneously optimized several green roof ecosystem functions, outperforming monocultures and single life-form groups, but there was much variation in performance depending on which life-forms were present in the three life-form mixtures. Some mixtures outperformed the best monocultures for water capture, evapotranspiration, and an index combining both water capture and temperature reductions. Combinations of tall forbs, grasses and succulents simultaneously optimized a range of ecosystem performance measures, thus the main benefit of including all three groups was not to maximize any single process but to perform a variety of functions well. Ecosystem services from green roofs can be improved by planting certain life-form groups in combination, directly contributing to climate change mitigation and adaptation strategies. The strong performance by certain mixtures of life-forms, especially tall forbs, grasses and succulents, warrants further investigation into niche complementarity or facilitation as mechanisms governing biodiversity-ecosystem functioning relationships in green roof ecosystems.

  8. Plant Species and Functional Group Combinations Affect Green Roof Ecosystem Functions

    PubMed Central

    Lundholm, Jeremy; MacIvor, J. Scott; MacDougall, Zachary; Ranalli, Melissa

    2010-01-01

    Background Green roofs perform ecosystem services such as summer roof temperature reduction and stormwater capture that directly contribute to lower building energy use and potential economic savings. These services are in turn related to ecosystem functions performed by the vegetation layer such as radiation reflection and transpiration, but little work has examined the role of plant species composition and diversity in improving these functions. Methodology/Principal Findings We used a replicated modular extensive (shallow growing- medium) green roof system planted with monocultures or mixtures containing one, three or five life-forms, to quantify two ecosystem services: summer roof cooling and water capture. We also measured the related ecosystem properties/processes of albedo, evapotranspiration, and the mean and temporal variability of aboveground biomass over four months. Mixtures containing three or five life-form groups, simultaneously optimized several green roof ecosystem functions, outperforming monocultures and single life-form groups, but there was much variation in performance depending on which life-forms were present in the three life-form mixtures. Some mixtures outperformed the best monocultures for water capture, evapotranspiration, and an index combining both water capture and temperature reductions. Combinations of tall forbs, grasses and succulents simultaneously optimized a range of ecosystem performance measures, thus the main benefit of including all three groups was not to maximize any single process but to perform a variety of functions well. Conclusions/Significance Ecosystem services from green roofs can be improved by planting certain life-form groups in combination, directly contributing to climate change mitigation and adaptation strategies. The strong performance by certain mixtures of life-forms, especially tall forbs, grasses and succulents, warrants further investigation into niche complementarity or facilitation as mechanisms governing biodiversity-ecosystem functioning relationships in green roof ecosystems. PMID:20300196

  9. Moderate energy restriction with high protein diet results in healthier outcome in women.

    PubMed

    Mero, Antti A; Huovinen, Heikki; Matintupa, Olle; Hulmi, Juha J; Puurtinen, Risto; Hohtari, Hannele; Karila, Tuomo Am

    2010-01-25

    The present study compares two different weight reduction regimens both with a moderately high protein intake on body composition, serum hormone concentration and strength performance in non-competitive female athletes. Fifteen normal weighted women involved in recreational resistance training and aerobic training were recruited for the study (age 28.5 +/- 6.3 yr, height 167.0 +/- 7.0 cm, body mass 66.3 +/- 4.2 kg, body mass index 23.8 +/- 1.8, mean +/- SD). They were randomized into two groups. The 1 KG group (n = 8; energy deficit 1100 kcal/day) was supervised to reduce body weight by 1 kg per week and the 0.5 KG group (n = 7; energy deficit 550 kcal/day) by 0.5 kg per week, respectively. In both groups protein intake was kept at least 1.4 g/kg body weight/day and the weight reduction lasted four weeks. At the beginning of the study the energy need was calculated using food and training diaries. The same measurements were done before and after the 4-week weight reduction period including total body composition (DXA), serum hormone concentrations, jumping ability and strength measurements During the 4-week weight reduction period there were no changes in lean body mass and bone mass, but total body mass, fat mass and fat percentage decreased significantly in both groups. The changes were greater in the 1 KG group than in the 0.5 KG group in total body mass (p < 0.001), fat mass (p < 0.001) and fat percentage (p < 0.01). Serum testosterone concentration decreased significantly from 1.8 +/- 1.0 to 1.4 +/- 0.9 nmol/l (p < 0.01) in 1 KG and the change was greater in 1 KG (30%, p < 0.001) than in 0.5 KG (3%). On the other hand, SHBG increased significantly in 1 KG from 63.4 +/- 17.7 to 82.4 +/- 33.0 nmol/l (p < 0.05) during the weight reducing regimen. After the 4-week period there were no changes in strength performance in 0.5 KG group, however in 1 KG maximal strength in bench press decreased (p < 0.05) while endurance strength in squat and counter movement jump improved (p < 0.05) It is concluded that a weight reduction by 0.5 kg per week with ~1.4 g protein/kg body weight/day can be recommended to normal weighted, physically active women instead of a larger (e.g. 1 kg per week) weight reduction because the latter may lead to a catabolic state. Vertical jumping performance is improved when fat mass and body weight decrease. Thus a moderate weight reduction prior to a major event could be considered beneficial for normal built athletes in jumping events.

  10. Tadpole swimming performance and activity affected by acute exposure to sublethal levels of carbaryl

    USGS Publications Warehouse

    Bridges, C.M.

    1997-01-01

    General activity and swimming performance (i.e., sprint speed and distance) of plains leopard frog tadpoles (Rana blairi) were examined after acute exposure to three sublethal concentrations of carbaryl (3.5, 5.0, and 7.2 mg/L). Both swimming performance and spontaneous swimming activity are important for carrying out life history functions (e.g., growth and development) and for escaping from predators. Measured tadpole activity diminished by nearly 90% at 3.5 mg/L carbaryl and completely ceased at 7.2 mg/L. Sprint speed and sprint distance also decreased significantly following exposure. Carbaryl affected both swimming performance and activity after just 24 h, suggesting that 24 h may be an adequate length of exposure to determine behavioral effects on tadpoles. Slight recovery of activity levels was noted at 24 and 48 h post-exposure; no recovery of swimming performance was observed. Reduction in activity and swimming performance may result in increased predation rates and, because activity is closely associated with feeding, may result in slowed growth leading to a failure to emerge before pond drying or an indirect reduction in adult fitness. Acute exposure to sublethal toxicants such as carbaryl may not only affect immediate survival of tadpoles but also impact critical life history functions and generate changes at the local population level.

  11. Tornado detection data reduction and analysis

    NASA Technical Reports Server (NTRS)

    Davisson, L. D.

    1977-01-01

    Data processing and analysis was provided in support of tornado detection by analysis of radio frequency interference in various frequency bands. Sea state determination data from short pulse radar measurements were also processed and analyzed. A backscatter simulation was implemented to predict radar performance as a function of wind velocity. Computer programs were developed for the various data processing and analysis goals of the effort.

  12. Investigation of the Performance of Commercial Batteries; Part II.

    ERIC Educational Resources Information Center

    Davies, Arthur; And Others

    1996-01-01

    Describes a project that involves determining, by coulometry, the energy output of different types and makes of 1.5-volt AA cells as a function of EMF and time. Involves measuring the volume of hydrogen gas collected at the cathode from the reduction of hydrogen ions in aqueous sulfuric acid by a current produced by the discharge of an AA battery.…

  13. Fly-scan ptychography

    DOE PAGES

    Huang, Xiaojing; Lauer, Kenneth; Clark, Jesse N.; ...

    2015-03-13

    We report an experimental ptychography measurement performed in fly-scan mode. With a visible-light laser source, we demonstrate a 5-fold reduction of data acquisition time. By including multiple mutually incoherent modes into the incident illumination, high quality images were successfully reconstructed from blurry diffraction patterns. Thus, this approach significantly increases the throughput of ptychography, especially for three-dimensional applications and the visualization of dynamic systems.

  14. 40 CFR Table 4 to Subpart Sssss to... - Requirements for Performance Tests

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... OM&M plan; and (6) If complying with the THC concentration or THC percentage reduction limits... continuous process unit that is subject to the THC emission limit listed in item 2.a., 3.a., 4, or 5 of Table 1 to this subpart a. Measure THC concentrations at the outlet of the control device or in the stack...

  15. 40 CFR Table 4 to Subpart Sssss to... - Requirements for Performance Tests

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... OM&M plan; and (6) If complying with the THC concentration or THC percentage reduction limits... continuous process unit that is subject to the THC emission limit listed in item 2.a., 3.a., 4, or 5 of Table 1 to this subpart a. Measure THC concentrations at the outlet of the control device or in the stack...

  16. 40 CFR Table 4 to Subpart Sssss to... - Requirements for Performance Tests

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... OM&M plan; and (6) If complying with the THC concentration or THC percentage reduction limits... continuous process unit that is subject to the THC emission limit listed in item 2.a., 3.a., 4, or 5 of Table 1 to this subpart a. Measure THC concentrations at the outlet of the control device or in the stack...

  17. 40 CFR Table 4 to Subpart Sssss to... - Requirements for Performance Tests

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... OM&M plan; and (6) If complying with the THC concentration or THC percentage reduction limits... continuous process unit that is subject to the THC emission limit listed in item 2.a., 3.a., 4, or 5 of Table 1 to this subpart a. Measure THC concentrations at the outlet of the control device or in the stack...

  18. 40 CFR Table 4 to Subpart Sssss to... - Requirements for Performance Tests

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... OM&M plan; and (6) If complying with the THC concentration or THC percentage reduction limits... continuous process unit that is subject to the THC emission limit listed in item 2.a., 3.a., 4, or 5 of Table 1 to this subpart a. Measure THC concentrations at the outlet of the control device or in the stack...

  19. Electrochemical Reduction Properties of Extended Space Charge InGaP and GaP Epitaxial Layers

    DOE PAGES

    Parameshwaran, Vijay; Xu, Xiaoqing; Clemens, Bruce

    2016-06-17

    Two lattice-matched epitaxial III-V phosphide films of thicknesses between 400 and 500 nm are grown by metal-organic chemical vapor deposition: InGaP on GaAs and GaP on Si. These structures are designed as photocathodes for solar-driven chemical reduction processes such as the hydrogen evolution reaction (HER) and CO 2 reduction into higher-order hydrocarbons. By using p + substrates and undoped epitaxial layers, an extended space-charge active region is achieved in the electrode with a design analogous to a p-i-n solar cell. When in contact with the methyl viologen MV + / + + redox couple, the InGaP/GaAs and GaP/Si cathodes generatemore » a photovoltage of 388 mV and 274 mV, respectively, under 1 sun illumination. Incident photon-to-current efficiency (IPCE) measurements confirm that the undoped active layers are exclusively performing light absorption and minority carrier diffusion-based charge transfer of high-energy photons. This shows that performance can be significantly boosted with lower-doped substrates. The InGaP/GaAs and GaP/Si electrodes are shown to drive the HER at saturation photocurrent densities of 9.05 mA/cm 2 and 2.34 mA/cm 2, respectively, under 1 sun illumination without a co-catalyst and under a large reduction bias. As a result, thicker films did not show a corresponding increased performance, and can be explained through understanding of crystalline defects and the electrostatics of the junctions.« less

  20. An evaluation of rational-emotive imagery as a component of rational-emotive therapy in the treatment of test anxiety.

    PubMed

    Hymen, S P; Warren, R

    1978-06-01

    This study evaluated the efficacy of rational-emotive imagery as a component of rational-emotive therapy in reduction of college students' test anxiety. 11 volunteers met for 6 1-hr. group treatment sessions over a 3-wk. period. After 2 initial treatment sessions subjects were randomly assigned to groups given either rational-emotive therapy with rational-emotive imagery or rational-emotive therapy without imagery. Contrary to predictions, improvement between groups on self-report and performance measures was nonsignificant. Failure to obtain differences was attributed to similarities in content of treatment sessions and short treatment time. Combined groups reported significant improvement on all dependent measures. Although the study did not yield the predicted benefits of the imagery, results lend further support to the efficacy of rational-emotive therapy procedures in the reduction of test anxiety.

  1. Magnetic pinning in a superconducting film by a ferromagnetic layer with stripe domains

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mancusi, D.; Di Giorgio, C.; Bobba, F.

    2014-10-31

    A magnetic study of superconductor/ferromagnet bilayers was performed by hysteresis loops and temperature-dependent magnetization measurements. The superconductor/ferromagnet bilayers consist of a Nb film deposited on a Py film with weak perpendicular magnetic anisotropy. By comparing the temperature-dependent magnetization data obtained on samples with different ferromagnetic layer thickness, a decrease of the magnetic pinning with increasing thickness of the ferromagnetic layer has been found. This is confirmed by the reduction of the Nb film critical current density at low fields extracted by using the magnetic irreversibility of the hysteresis loops. As the ferromagnetic layer exhibits a magnetic structure with stripe domains,more » whose width increases for increasing thickness as observed by magnetic force microscopy (MFM) measurements, we relate the reduction of the superconducting critical current in samples with thicker ferromagnetic layers to a weaker interaction between the vortices guided by the underlying magnetic template.« less

  2. The Dornier 328 Acoustic Test Cell (ATC) for interior noise tests and selected test results

    NASA Technical Reports Server (NTRS)

    Hackstein, H. Josef; Borchers, Ingo U.; Renger, Klaus; Vogt, Konrad

    1992-01-01

    To perform acoustic studies for achieving low noise levels for the Dornier 328, an acoustic test cell (ATC) of the Dornier 328 has been built. The ATC consists of a fuselage section, a realistic fuselage suspension system, and three exterior noise simulation rings. A complex digital 60 channel computer/amplifier noise generation system as well as multichannel digital data acquisition and evaluation system have been used. The noise control tests started with vibration measurements for supporting acoustic data interpretation. In addition, experiments have been carried out on dynamic vibration absorbers, the most important passive noise reduction measure for low frequency propeller noise. The design and arrangement of the current ATC are presented. Furthermore, exterior noise simulation as well as data acquisition are explained. The most promising results show noise reduction due to synchrophasing and dynamic vibration absorbers.

  3. Pollution measurements of a swirl-can combustor

    NASA Technical Reports Server (NTRS)

    Niedzwiecki, R. W.; Jones, R. E.

    1972-01-01

    Pollutant levels of oxides of nitrogen, unburned hydrocarbons, and carbon monoxide were measured for an experimental, annular, swirl can combustor. The combustor was 42 inches in diameter, incorporated 120 modules, and was specifically designed for elevated exit temperature performance. Test conditions included combustor inlet temperatures of 600, 900 and 1050 F, inlet pressures of 5 to 6 atmospheres, reference velocities of 69 to 120 feet per second and fuel-air ratios of 0.014 to 0.0695. Tests were also conducted at a simulated engine idle condition. Results demonstrated that swirl can combustors produce oxides of nitrogen levels substantially lower than conventional combustor designs. These reductions are attributed to reduced dwell times resulting from short combustor length, quick mixing of combustion gases with diluent air, and to uniform fuel distributions resulting from the swirl can approach. Radial staging of fuel at idle conditions resulted in increases in combustion efficiencies and corresponding reductions in pollutant levels.

  4. Combustion performance evaluation of air staging of palm oil blends.

    PubMed

    Mohd Jaafar, Mohammad Nazri; Eldrainy, Yehia A; Mat Ali, Muhammad Faiser; Wan Omar, W Z; Mohd Hizam, Mohd Faizi Arif

    2012-02-21

    The problems of global warming and the unstable price of petroleum oils have led to a race to develop environmentally friendly biofuels, such as palm oil or ethanol derived from corn and sugar cane. Biofuels are a potential replacement for fossil fuel, since they are renewable and environmentally friendly. This paper evaluates the combustion performance and emission characteristics of Refined, Bleached, and Deodorized Palm Oil (RBDPO)/diesel blends B5, B10, B15, B20, and B25 by volume, using an industrial oil burner with and without secondary air. Wall temperature profiles along the combustion chamber axis were measured using a series of thermocouples fitted axially on the combustion chamber wall, and emissions released were measured using a gas analyzer. The results show that RBDPO blend B25 produced the maximum emission reduction of 56.9% of CO, 74.7% of NOx, 68.5% of SO(2), and 77.5% of UHC compared to petroleum diesel, while air staging (secondary air) in most cases reduces the emissions further. However, increasing concentrations of RBDPO in the blends also reduced the energy released from the combustion. The maximum wall temperature reduction was 62.7% for B25 at the exit of the combustion chamber.

  5. Radiation dose reduction to the breast in thoracic CT: Comparison of bismuth shielding, organ-based tube current modulation, and use of a globally decreased tube current

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang Jia; Duan Xinhui; Christner, Jodie A.

    2011-11-15

    Purpose: The purpose of this work was to evaluate dose performance and image quality in thoracic CT using three techniques to reduce dose to the breast: bismuth shielding, organ-based tube current modulation (TCM) and global tube current reduction. Methods: Semi-anthropomorphic thorax phantoms of four different sizes (15, 30, 35, and 40 cm lateral width) were used for dose measurement and image quality assessment. Four scans were performed on each phantom using 100 or 120 kV with a clinical CT scanner: (1) reference scan; (2) scan with bismuth breast shield of an appropriate thickness; (3) scan with organ-based TCM; and (4)more » scan with a global reduction in tube current chosen to match the dose reduction from bismuth shielding. Dose to the breast was measured with an ion chamber on the surface of the phantom. Image quality was evaluated by measuring the mean and standard deviation of CT numbers within the lung and heart regions. Results: Compared to the reference scan, dose to the breast region was decreased by about 21% for the 15-cm phantom with a pediatric (2-ply) shield and by about 37% for the 30, 35, and 40-cm phantoms with adult (4-ply) shields. Organ-based TCM decreased the dose by 12% for the 15-cm phantom, and 34-39% for the 30, 35, and 40-cm phantoms. Global lowering of the tube current reduced breast dose by 23% for the 15-cm phantom and 39% for the 30, 35, and 40-cm phantoms. In phantoms of all four sizes, image noise was increased in both the lung and heart regions with bismuth shielding. No significant increase in noise was observed with organ-based TCM. Decreasing tube current globally led to similar noise increases as bismuth shielding. Streak and beam hardening artifacts, and a resulting artifactual increase in CT numbers, were observed for scans with bismuth shields, but not for organ-based TCM or global tube current reduction. Conclusions: Organ-based TCM produces dose reduction to the breast similar to that achieved with bismuth shielding for both pediatric and adult phantoms. However, organ-based TCM does not affect image noise or CT number accuracy, both of which are adversely affected by bismuth shielding. Alternatively, globally decreasing the tube current can produce the same dose reduction to the breast as bismuth shielding, with a similar noise increase, yet without the streak artifacts and CT number errors caused by the bismuth shields. Moreover, globally decreasing the tube current reduces the dose to all tissues scanned, not simply to the breast.« less

  6. Design, Fabrication, and Testing of SMA Enabled Adaptive Chevrons for Jet Noise Reduction

    NASA Technical Reports Server (NTRS)

    Turner, Travis L.; Buehrle, Ralph D.; Cano, Roberto J.; Fleming, Gary A.

    2004-01-01

    This study presents the status and results from an effort to design, fabricate, and test an adaptive jet engine chevron concept based upon embedding shape memory alloy (SMA) actuators in a composite laminate, termed a SMA hybrid composite (SMAHC). The approach for fabricating the adaptive SMAHC chevrons involves embedding prestrained Nitinol actuators on one side of the mid-plane of the composite laminate such that thermal excitation generates a thermal moment and deflects the structure. A glass-epoxy pre-preg/Nitinol ribbon material system and a vacuum hot press consolidation approach are employed. A versatile test system for control and measurement of the chevron deflection performance is described. Projection moire interferometry (PMI) is used for global deformation measurement and infrared (IR) thermography is used for 2-D temperature measurement and feedback control. A recently commercialized constitutive model for SMA and SMAHC materials is used in the finite element code ABAQUS to perform nonlinear static analysis of the chevron prototypes. Excellent agreement is achieved between the predicted and measured chevron deflection performance, thereby validating the design tool. Although the performance results presented in this paper fall short of the requirement, the concept is proven and an approach for achieving the performance objectives is evident.

  7. Comparison between orogastric tube/bougie and a suction calibration system for effects on operative duration, staple-line corkscrewing, and esophageal perforation during laparoscopic sleeve gastrectomy.

    PubMed

    Gagner, Michel; Huang, Rose Y

    2016-04-01

    Placement of a bougie for sleeve sizing during laparoscopic sleeve gastrectomy (LSG) is recommended. We compared this standard with a suction calibration system (SCS) that performs all functions with one insertion, and measured each step's duration. Primary LSG was performed using a bougie and SCS in alternating order. Number of tube movements to achieve optimal placement, durations of decompression, leak testing, and overall operative time, and remnant linear measurements were obtained. LSG was performed in 26 patients (15 women, 11 men; mean age 36.8 years; mean BMI 45.3 kg/m(2)). The mean number of tube movements was significantly greater for the bougie than for the SCS (8.13 vs. 3.58; p < 0.0001). Percent reductions achieved using the SCS were: time to full decompression of the stomach, 62% (21 vs. 8 s; p < 0.138); tube placement, 51% (101 vs. 49 s; p < 0.0001); leak testing, 78% (119 vs. 26 s; p < 0.0003); and mean operative duration (from tube insertion to end of stapling), 21% (875 vs. 697 s; p < 0.019). Variance of the staple-line distance, measured from the greater curvature to the staple line, was 1.64 and 0.92 for the bougie and SCS, respectively, indicating a reduction in corkscrewing, for a 43.9% straighter sleeve. SCS maintained the gastric wall in place, thereby preventing corkscrewing, and reducing total operating time. Reducing the number of tube insertions may prevent esophageal damage and accidental tube stapling.

  8. Monitoring stage fright outside the laboratory: an example in a professional musician using wearable sensors.

    PubMed

    Kusserow, Martin; Candia, Victor; Amft, Oliver; Hildebrandt, Horst; Folkers, Gerd; Tröster, Gerhard

    2012-03-01

    We implemented and tested a wearable sensor system to measure patterns of stress responses in a professional musician under public performance conditions. Using this sensor system, we monitored the cellist's heart activity, the motion of multiple body parts, and their gradual changes during three repeated performances of a skill-demanding piece in front of a professional audience. From the cellist and her teachers, we collected stage fright self-reports and performance ratings that were related to our sensor data analysis results. Concomitant to changes in body motion and heart rate, the cellist perceived a reduction in stage fright. Performance quality was objectively improved, as technical playing errors decreased throughout repeated renditions. In particular, from performance 1 to 3, the wearable sensors measured a significant increase in the cellist's bowing motion dynamics of approximately 6% and a decrease in heart rate. Bowing motion showed a marginal correlation to the observed heart rate patterns during playing. The wearable system did not interfere with the cellist's performance, thereby allowing investigation of stress responses during natural public performances.

  9. Optimal Electrode Selection for Electrical Resistance Tomography in Carbon Fiber Reinforced Polymer Composites

    PubMed Central

    Escalona Galvis, Luis Waldo; Diaz-Montiel, Paulina; Venkataraman, Satchi

    2017-01-01

    Electrical Resistance Tomography (ERT) offers a non-destructive evaluation (NDE) technique that takes advantage of the inherent electrical properties in carbon fiber reinforced polymer (CFRP) composites for internal damage characterization. This paper investigates a method of optimum selection of sensing configurations for delamination detection in thick cross-ply laminates using ERT. Reduction in the number of sensing locations and measurements is necessary to minimize hardware and computational effort. The present work explores the use of an effective independence (EI) measure originally proposed for sensor location optimization in experimental vibration modal analysis. The EI measure is used for selecting the minimum set of resistance measurements among all possible combinations resulting from selecting sensing electrode pairs. Singular Value Decomposition (SVD) is applied to obtain a spectral representation of the resistance measurements in the laminate for subsequent EI based reduction to take place. The electrical potential field in a CFRP laminate is calculated using finite element analysis (FEA) applied on models for two different laminate layouts considering a set of specified delamination sizes and locations with two different sensing arrangements. The effectiveness of the EI measure in eliminating redundant electrode pairs is demonstrated by performing inverse identification of damage using the full set and the reduced set of resistance measurements. This investigation shows that the EI measure is effective for optimally selecting the electrode pairs needed for resistance measurements in ERT based damage detection. PMID:28772485

  10. Optimal Electrode Selection for Electrical Resistance Tomography in Carbon Fiber Reinforced Polymer Composites.

    PubMed

    Escalona Galvis, Luis Waldo; Diaz-Montiel, Paulina; Venkataraman, Satchi

    2017-02-04

    Electrical Resistance Tomography (ERT) offers a non-destructive evaluation (NDE) technique that takes advantage of the inherent electrical properties in carbon fiber reinforced polymer (CFRP) composites for internal damage characterization. This paper investigates a method of optimum selection of sensing configurations for delamination detection in thick cross-ply laminates using ERT. Reduction in the number of sensing locations and measurements is necessary to minimize hardware and computational effort. The present work explores the use of an effective independence (EI) measure originally proposed for sensor location optimization in experimental vibration modal analysis. The EI measure is used for selecting the minimum set of resistance measurements among all possible combinations resulting from selecting sensing electrode pairs. Singular Value Decomposition (SVD) is applied to obtain a spectral representation of the resistance measurements in the laminate for subsequent EI based reduction to take place. The electrical potential field in a CFRP laminate is calculated using finite element analysis (FEA) applied on models for two different laminate layouts considering a set of specified delamination sizes and locations with two different sensing arrangements. The effectiveness of the EI measure in eliminating redundant electrode pairs is demonstrated by performing inverse identification of damage using the full set and the reduced set of resistance measurements. This investigation shows that the EI measure is effective for optimally selecting the electrode pairs needed for resistance measurements in ERT based damage detection.

  11. Reduction in nosocomial infection with improved hand hygiene in intensive care units of a tertiary care hospital in Argentina.

    PubMed

    Rosenthal, Victor D; Guzman, Sandra; Safdar, Nasia

    2005-09-01

    Hand hygiene is a fundamental measure for the control of nosocomial infection. However, sustained compliance with hand hygiene in health care workers is poor. We attempted to enhance compliance with hand hygiene by implementing education, training, and performance feedback. We measured nosocomial infections in parallel. We monitored the overall compliance with hand hygiene during routine patient care in intensive care units (ICUs); 1 medical surgical ICU and 1 coronary ICU, of 1 hospital in Buenos Aires, Argentina, before and during implementation of a hand hygiene education, training, and performance feedback program. Observational surveys were done twice a week from September 2000 to May 2002. Nosocomial infections in the ICUs were identified using the National Nosocomial Infections Surveillance (NNIS) criteria, with prospective surveillance. We observed 4347 opportunities for hand hygiene in both ICUs. Compliance improved progressively (handwashing adherence, 23.1% (268/1160) to 64.5% (2056/3187) (RR, 2.79; 95% CI: 2.46-3.17; P < .0001). During the same period, overall nosocomial infection in both ICUs decreased from 47.55 per 1000 patient-days (104/2187) to 27.93 per 1000 patient days (207/7409) RR, 0.59; 95% CI: 0.46-0.74, P < .0001). A program consisting of focused education and frequent performance feedback produced a sustained improvement in compliance with hand hygiene, coinciding with a reduction in nosocomial infection rates in the ICUs.

  12. High-Performance Platinum-Free Dye-Sensitized Solar Cells with Molybdenum Disulfide Films as Counter Electrodes.

    PubMed

    Hussain, Sajjad; Shaikh, Shoyebmohamad F; Vikraman, Dhanasekaran; Mane, Rajaram S; Joo, Oh-Shim; Naushad, Mu; Jung, Jongwan

    2015-12-21

    By using a radio-frequency sputtering method, we synthesized large-area, uniform, and transparent molybdenum disulfide film electrodes (1, 3, 5, and 7 min) on transparent and conducting fluorine-doped tin oxide (FTO), as ecofriendly, cost-effective counter electrodes (CE) for dye-sensitized solar cells (DSSCs). These CEs were used in place of the routinely used expensive platinum CEs for the catalytic reduction of a triiodide electrolyte. The structure and morphology of the MoS2 was analyzed by using Raman spectroscopy, X-ray diffraction, and X-ray photoemission spectroscopy measurements and the DSSC characteristics were investigated. An unbroken film of MoS2 was identified on the FTO crystallites from field-emission scanning electron microscopy. Cyclic voltammetry, electrochemical impedance spectroscopy, and Tafel curve measurements reveal the promise of MoS2 as a CE with a low charge-transfer resistance, high electrocatalytic activity, and fast reaction kinetics for the reduction of triiodide to iodide. Finally, an optimized transparent MoS2 CE, obtained after 5 min synthesis time, showed a high power-conversion efficiency of 6.0 %, which comparable to the performance obtained with a Pt CE (6.6 %) when used in TiO2 -based DSCCs, thus signifying the importance of sputtering time on DSSC performance. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Update on Risk Reduction Activities for a Liquid Advanced Booster for NASA's Space Launch System

    NASA Technical Reports Server (NTRS)

    Crocker, Andrew M.; Greene, William D.

    2017-01-01

    The stated goals of NASA's Research Announcement for the Space Launch System (SLS) Advanced Booster Engineering Demonstration and/or Risk Reduction (ABEDRR) are to reduce risks leading to an affordable Advanced Booster that meets the evolved capabilities of SLS and enable competition by mitigating targeted Advanced Booster risks to enhance SLS affordability. Dynetics, Inc. and Aerojet Rocketdyne (AR) formed a team to offer a wide-ranging set of risk reduction activities and full-scale, system-level demonstrations that support NASA's ABEDRR goals. During the ABEDRR effort, the Dynetics Team has modified flight-proven Apollo-Saturn F-1 engine components and subsystems to improve affordability and reliability (e.g., reduce parts counts, touch labor, or use lower cost manufacturing processes and materials). The team has built hardware to validate production costs and completed tests to demonstrate it can meet performance requirements. State-of-the-art manufacturing and processing techniques have been applied to the heritage F-1, resulting in a low recurring cost engine while retaining the benefits of Apollo-era experience. NASA test facilities have been used to perform low-cost risk-reduction engine testing. In early 2014, NASA and the Dynetics Team agreed to move additional large liquid oxygen/kerosene engine work under Dynetics' ABEDRR contract. Also led by AR, the objectives of this work are to demonstrate combustion stability and measure performance of a 500,000 lbf class Oxidizer-Rich Staged Combustion (ORSC) cycle main injector. A trade study was completed to investigate the feasibility, cost effectiveness, and technical maturity of a domestically-produced engine that could potentially both replace the RD-180 on Atlas V and satisfy NASA SLS payload-to-orbit requirements via an advanced booster application. Engine physical dimensions and performance parameters resulting from this study provide the system level requirements for the ORSC risk reduction test article. The test article is scheduled to complete fabrication and assembly soon and continue testing through late 2019. Dynetics has also designed, developed, and built innovative tank and structure assemblies using friction stir welding to leverage recent NASA investments in manufacturing tools, facilities, and processes, significantly reducing development and recurring costs. The full-scale cryotank assembly was used to verify the structural design and prove affordable processes. Dynetics performed hydrostatic and cryothermal proof tests on the assembly to verify the assembly meets performance requirements..

  14. OXIDATION-REDUCTION POTENTIAL MEASUREMENTS OF IMPORTANT OXIDANTS IN DRINKING WATER

    EPA Science Inventory

    Oxidation-reduction (redox) reactions are important in drinking water treatment and distribution. Oxidation-reduction potential (ORP) measurements of water reflect the tendency of major constituents in the water to accept or lose electrons. Although ORP measurements are valuable...

  15. A carbon CT system: how to obtain accurate stopping power ratio using a Bragg peak reduction technique

    NASA Astrophysics Data System (ADS)

    Lee, Sung Hyun; Sunaguchi, Naoki; Hirano, Yoshiyuki; Kano, Yosuke; Liu, Chang; Torikoshi, Masami; Ohno, Tatsuya; Nakano, Takashi; Kanai, Tatsuaki

    2018-02-01

    In this study, we investigate the performance of the Gunma University Heavy Ion Medical Center’s ion computed tomography (CT) system, which measures the residual range of a carbon-ion beam using a fluoroscopy screen, a charge-coupled-device camera, and a moving wedge absorber and collects CT reconstruction images from each projection angle. Each 2D image was obtained by changing the polymethyl methacrylate (PMMA) thickness, such that all images for one projection could be expressed as the depth distribution in PMMA. The residual range as a function of PMMA depth was related to the range in water through a calibration factor, which was determined by comparing the PMMA-equivalent thickness measured by the ion CT system to the water-equivalent thickness measured by a water column. Aluminium, graphite, PMMA, and five biological phantoms were placed in a sample holder, and the residual range for each was quantified simultaneously. A novel method of CT reconstruction to correct for the angular deflection of incident carbon ions in the heterogeneous region utilising the Bragg peak reduction (BPR) is also introduced in this paper, and its performance is compared with other methods present in the literature such as the decomposition and differential methods. Stopping power ratio values derived with the BPR method from carbon-ion CT images matched closely with the true water-equivalent length values obtained from the validation slab experiment.

  16. Waste in the U.S. Health Care System: A Conceptual Framework

    PubMed Central

    Bentley, Tanya G K; Effros, Rachel M; Palar, Kartika; Keeler, Emmett B

    2008-01-01

    Context Health care costs in the United States are much higher than those in industrial countries with similar or better health system performance. Wasteful spending has many undesirable consequences that could be alleviated through waste reduction. This article proposes a conceptual framework to guide researchers and policymakers in evaluating waste, implementing waste-reduction strategies, and reducing the burden of unnecessary health care spending. Methods This article divides health care waste into administrative, operational, and clinical waste and provides an overview of each. It explains how researchers have used both high-level and sector- or procedure-specific comparisons to quantify such waste, and it discusses examples and challenges in both waste measurement and waste reduction. Findings Waste is caused by factors such as health insurance and medical uncertainties that encourage the production of inefficient and low-value services. Various efforts to reduce such waste have encountered challenges, such as the high costs of initial investment, unintended administrative complexities, and trade-offs among patients', payers', and providers' interests. While categorizing waste may help identify and measure general types and sources of waste, successful reduction strategies must integrate the administrative, operational, and clinical components of care, and proceed by identifying goals, changing systemic incentives, and making specific process improvements. Conclusions Classifying, identifying, and measuring waste elucidate its causes, clarify systemic goals, and specify potential health care reforms that—by improving the market for health insurance and health care—will generate incentives for better efficiency and thus ultimately decrease waste in the U.S. health care system. PMID:19120983

  17. A Hybrid Approach to Detect Driver Drowsiness Utilizing Physiological Signals to Improve System Performance and Wearability.

    PubMed

    Awais, Muhammad; Badruddin, Nasreen; Drieberg, Micheal

    2017-08-31

    Driver drowsiness is a major cause of fatal accidents, injury, and property damage, and has become an area of substantial research attention in recent years. The present study proposes a method to detect drowsiness in drivers which integrates features of electrocardiography (ECG) and electroencephalography (EEG) to improve detection performance. The study measures differences between the alert and drowsy states from physiological data collected from 22 healthy subjects in a driving simulator-based study. A monotonous driving environment is used to induce drowsiness in the participants. Various time and frequency domain feature were extracted from EEG including time domain statistical descriptors, complexity measures and power spectral measures. Features extracted from the ECG signal included heart rate (HR) and heart rate variability (HRV), including low frequency (LF), high frequency (HF) and LF/HF ratio. Furthermore, subjective sleepiness scale is also assessed to study its relationship with drowsiness. We used paired t -tests to select only statistically significant features ( p < 0.05), that can differentiate between the alert and drowsy states effectively. Significant features of both modalities (EEG and ECG) are then combined to investigate the improvement in performance using support vector machine (SVM) classifier. The other main contribution of this paper is the study on channel reduction and its impact to the performance of detection. The proposed method demonstrated that combining EEG and ECG has improved the system's performance in discriminating between alert and drowsy states, instead of using them alone. Our channel reduction analysis revealed that an acceptable level of accuracy (80%) could be achieved by combining just two electrodes (one EEG and one ECG), indicating the feasibility of a system with improved wearability compared with existing systems involving many electrodes. Overall, our results demonstrate that the proposed method can be a viable solution for a practical driver drowsiness system that is both accurate and comfortable to wear.

  18. A Hybrid Approach to Detect Driver Drowsiness Utilizing Physiological Signals to Improve System Performance and Wearability

    PubMed Central

    Badruddin, Nasreen

    2017-01-01

    Driver drowsiness is a major cause of fatal accidents, injury, and property damage, and has become an area of substantial research attention in recent years. The present study proposes a method to detect drowsiness in drivers which integrates features of electrocardiography (ECG) and electroencephalography (EEG) to improve detection performance. The study measures differences between the alert and drowsy states from physiological data collected from 22 healthy subjects in a driving simulator-based study. A monotonous driving environment is used to induce drowsiness in the participants. Various time and frequency domain feature were extracted from EEG including time domain statistical descriptors, complexity measures and power spectral measures. Features extracted from the ECG signal included heart rate (HR) and heart rate variability (HRV), including low frequency (LF), high frequency (HF) and LF/HF ratio. Furthermore, subjective sleepiness scale is also assessed to study its relationship with drowsiness. We used paired t-tests to select only statistically significant features (p < 0.05), that can differentiate between the alert and drowsy states effectively. Significant features of both modalities (EEG and ECG) are then combined to investigate the improvement in performance using support vector machine (SVM) classifier. The other main contribution of this paper is the study on channel reduction and its impact to the performance of detection. The proposed method demonstrated that combining EEG and ECG has improved the system’s performance in discriminating between alert and drowsy states, instead of using them alone. Our channel reduction analysis revealed that an acceptable level of accuracy (80%) could be achieved by combining just two electrodes (one EEG and one ECG), indicating the feasibility of a system with improved wearability compared with existing systems involving many electrodes. Overall, our results demonstrate that the proposed method can be a viable solution for a practical driver drowsiness system that is both accurate and comfortable to wear. PMID:28858220

  19. Norm-Optimal ILC Applied to a High-Speed Rack Feeder

    NASA Astrophysics Data System (ADS)

    Schindele, Dominik; Aschemann, Harald; Ritzke, Jöran

    2010-09-01

    Rack feeders as automated conveying systems for high bay rackings are of high practical importance. To shorten the transport times by using trajectories with increased kinematic values accompanying control measures for a reduction of the excited structural vibrations are necessary. In this contribution, the model-based design of a norm-optimal iterative learning control structure is presented. The rack feeder is modelled as an elastic multibody system. For the mathematical description of the bending deflections a Ritz ansatz is introduced. The tracking control design is performed separately for both axes using decentralised state space representations. Both the achievable performance and the resulting tracking accuracy of the proposed control concept are shown by measurement results from the experimental set-up.

  20. Assessing the value of diagnostic imaging: the role of perception

    NASA Astrophysics Data System (ADS)

    Potchen, E. J.; Cooper, Thomas G.

    2000-04-01

    The value of diagnostic radiology rests in its ability to provide information. Information is defined as a reduction in randomness. Quality improvement in any system requires diminution in the variation in its performance. The major variation in performance of the system of diagnostic radiology occurs in observer performance and in the communication of information from the observer to someone who will apply that information to the benefit of the patient. The ability to provide information can be determined by observer performance studies using a receiver-operating characteristic (ROC) curve analysis. The amount of information provided by each observer can be measured in terms of the uncertainty they reduce. Using a set of standardized radiographs, some normal and some abnormal, sorting them randomly, and then asking an observer to redistribute them according to their probability of normality can measure the difference in the value added by different observers. By applying this observer performance measure, we have been able to characterize individual radiologists, groups of radiologists, and regions of the United States in their ability to add value in chest radiology. The use of these technologies in health care may improve upon the contribution of diagnostic imaging.

  1. Subsonic flight test evaluation of a performance seeking control algorithm on an F-15 airplane

    NASA Technical Reports Server (NTRS)

    Gilyard, Glenn B.; Orme, John S.

    1992-01-01

    The subsonic flight test evaluation phase of the NASA F-15 (powered by F 100 engines) performance seeking control program was completed for single-engine operation at part- and military-power settings. The subsonic performance seeking control algorithm optimizes the quasi-steady-state performance of the propulsion system for three modes of operation. The minimum fuel flow mode minimizes fuel consumption. The minimum thrust mode maximizes thrust at military power. Decreases in thrust-specific fuel consumption of 1 to 2 percent were measured in the minimum fuel flow mode; these fuel savings are significant, especially for supersonic cruise aircraft. Decreases of up to approximately 100 degree R in fan turbine inlet temperature were measured in the minimum temperature mode. Temperature reductions of this magnitude would more than double turbine life if inlet temperature was the only life factor. Measured thrust increases of up to approximately 15 percent in the maximum thrust mode cause substantial increases in aircraft acceleration. The system dynamics of the closed-loop algorithm operation were good. The subsonic flight phase has validated the performance seeking control technology, which can significantly benefit the next generation of fighter and transport aircraft.

  2. Preparation of silver nanoparticles/graphene nanosheets as a catalyst for electrochemical oxidation of methanol

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Han, Kun; Miao, Peng; Tang, Yuguo, E-mail: tangyg@sibet.ac.cn

    2014-02-03

    In this report, silver nanoparticles (AgNPs) decorated graphene nanosheets have been prepared based on the reduction of Ag ions by hydroquinone, and their catalytic performance towards the electrochemical oxidation of methanol is investigated. The synthesis of the nano-composite is confirmed by transmission electron microscope measurements and UV-vis absorption spectra. Excellent electrocatalytic performance of the material is demonstrated by cyclic voltammograms. This material also contributes to the low peak potential of methanol oxidation compared with most of the other materials.

  3. Macular Carotenoid Supplementation Improves Visual Performance, Sleep Quality, and Adverse Physical Symptoms in Those with High Screen Time Exposure

    PubMed Central

    Stringham, James M.; Stringham, Nicole T.; O’Brien, Kevin J.

    2017-01-01

    The dramatic rise in the use of smartphones, tablets, and laptop computers over the past decade has raised concerns about potentially deleterious health effects of increased “screen time” (ST) and associated short-wavelength (blue) light exposure. We determined baseline associations and effects of 6 months’ supplementation with the macular carotenoids (MC) lutein, zeaxanthin, and mesozeaxanthin on the blue-absorbing macular pigment (MP) and measures of sleep quality, visual performance, and physical indicators of excessive ST. Forty-eight healthy young adults with at least 6 h of daily near-field ST exposure participated in this placebo-controlled trial. Visual performance measures included contrast sensitivity, critical flicker fusion, disability glare, and photostress recovery. Physical indicators of excessive screen time and sleep quality were assessed via questionnaire. MP optical density (MPOD) was assessed via heterochromatic flicker photometry. At baseline, MPOD was correlated significantly with all visual performance measures (p < 0.05 for all). MC supplementation (24 mg daily) yielded significant improvement in MPOD, overall sleep quality, headache frequency, eye strain, eye fatigue, and all visual performance measures, versus placebo (p < 0.05 for all). Increased MPOD significantly improves visual performance and, in turn, improves several undesirable physical outcomes associated with excessive ST. The improvement in sleep quality was not directly related to increases in MPOD, and may be due to systemic reduction in oxidative stress and inflammation. PMID:28661438

  4. Macular Carotenoid Supplementation Improves Visual Performance, Sleep Quality, and Adverse Physical Symptoms in Those with High Screen Time Exposure.

    PubMed

    Stringham, James M; Stringham, Nicole T; O'Brien, Kevin J

    2017-06-29

    The dramatic rise in the use of smartphones, tablets, and laptop computers over the past decade has raised concerns about potentially deleterious health effects of increased "screen time" (ST) and associated short-wavelength (blue) light exposure. We determined baseline associations and effects of 6 months' supplementation with the macular carotenoids (MC) lutein, zeaxanthin, and mesozeaxanthin on the blue-absorbing macular pigment (MP) and measures of sleep quality, visual performance, and physical indicators of excessive ST. Forty-eight healthy young adults with at least 6 h of daily near-field ST exposure participated in this placebo-controlled trial. Visual performance measures included contrast sensitivity, critical flicker fusion, disability glare, and photostress recovery. Physical indicators of excessive screen time and sleep quality were assessed via questionnaire. MP optical density (MPOD) was assessed via heterochromatic flicker photometry. At baseline, MPOD was correlated significantly with all visual performance measures ( p < 0.05 for all). MC supplementation (24 mg daily) yielded significant improvement in MPOD, overall sleep quality, headache frequency, eye strain, eye fatigue, and all visual performance measures, versus placebo ( p < 0.05 for all). Increased MPOD significantly improves visual performance and, in turn, improves several undesirable physical outcomes associated with excessive ST. The improvement in sleep quality was not directly related to increases in MPOD, and may be due to systemic reduction in oxidative stress and inflammation.

  5. Bubble-detector measurements in the Russian segment of the International Space Station during 2009-12.

    PubMed

    Smith, M B; Khulapko, S; Andrews, H R; Arkhangelsky, V; Ing, H; Lewis, B J; Machrafi, R; Nikolaev, I; Shurshakov, V

    2015-01-01

    Measurements using bubble detectors have been performed in order to characterise the neutron dose and energy spectrum in the Russian segment of the International Space Station (ISS). Experiments using bubble dosemeters and a bubble-detector spectrometer, a set of six detectors with different energy thresholds that is used to determine the neutron spectrum, were performed during the ISS-22 (2009) to ISS-33 (2012) missions. The spectrometric measurements are in good agreement with earlier data, exhibiting expected features of the neutron energy spectrum in space. Experiments using a hydrogenous radiation shield show that the neutron dose can be reduced by shielding, with a reduction similar to that determined in earlier measurements using bubble detectors. The bubble-detector data are compared with measurements performed on the ISS using other instruments and are correlated with potential influencing factors such as the ISS altitude and the solar activity. Surprisingly, these influences do not seem to have a strong effect on the neutron dose or energy spectrum inside the ISS. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  6. Reductions in Multi-Component Jet Noise by Water Injection

    NASA Technical Reports Server (NTRS)

    Norum, Thomas D.

    2004-01-01

    An experimental investigation was performed in the NASA Langley Low Speed Aeroacoustics Wind Tunnel to determine the extent of jet exhaust noise reduction that can be obtained using water injection in a hot jet environment. The effects of water parameters such as mass flow rate, injection location, and spray patterns on suppression of dominant noise sources in both subsonic and supersonic jets were determined, and extrapolations to full-scale engine noise reduction were made. Water jets and sprays were injected in to the shear layers of cold and hot circular jets operating at both subsonic and supersonic exhaust conditions. Use of convergent-divergent and convergent nozzles (2.7in. D) allowed for simulations of all major jet noise sources. The experimental results show that water injection clearly disrupts shock noise sources within the jet plume, with large reductions in radiated shock noise. There are smaller reductions in jet mixing noise, resulting in only a small decrease in effective perceived noise level when projections are made to full scale. The fact that the measured noise reduction in the direction upstream of the nozzle was consistently larger than in the noisier downstream direction contributed to keeping effective perceived noise reductions small. Variations in the operation of the water injection system clearly show that injection at the nozzle exit rather than further downstream is required for the largest noise reduction. Noise reduction increased with water pressure as well as with its mass flow, although the type of injector had little effect.

  7. Biatrial reduction plasty with reef imbricate technique as an adjunct to maze procedure for permanent atrial fibrillation associated with giant left atria.

    PubMed

    Wang, William; Guo, L Ray; Martland, Anne Marie; Feng, Xiao-Dong; Ma, Jie; Feng, Xi Qing

    2010-04-01

    Success of the modified maze procedure after valvular operation with giant atria and permanent atrial fibrillation (AF) remains suboptimal. We report an aggressive approach for these patients utilizing biatrial reduction plasty with a reef imbricate suture technique concomitantly with valvular and maze procedure for AF. From January 1999 to December 2006, 122 consecutive Chinese patients with permanent AF and biatrial enlargement who required mitral valve+/-tricuspid valve (TV) surgery underwent aggressive left atrial reduction combined with radiofrequency bipolar full maze procedure. Left atrial dimensions were measured by TTE or TEE. There were 71 women (58.1%) and 51 men (41.9%) and their mean age was 45+/-9.5 years. Mean duration of AF was 48.4+/-21.4 months. All patients underwent left atrial reduction plasty with reef imbricate suture technique and full maze procedure. Their preoperative left atria measured 64+/-12 mm in the enlarged left atria (ELA) group and 86+/-17 mm in the giant left atria (GLA). Mitral valve replacement (MVR) combined with TV repair was performed in 102 patients (83%) while 21 patients underwent MVRs combined with aortic valve replacements (17%). Sixty-six (54%) patients required additional procedures and 61 (50%) of the patients also underwent left atrial appendage clot evacuation. Postoperative left atrial size was reduced to 49+/-8 mm (ELA) and 51+/-11 mm (GLA), respectively (P<0.05). Ninety-three of 122 (76%) patients were restored in normal sinus rhythm after one year clinical follow-up. Aggressive biatrial reduction plasty combined with full maze procedure is an effective treatment for patients with permanent AF undergoing concomitant valvular surgery. Further studies utilizing the reef imbricate suture technique for atrial reduction need to subsequently be evaluated.

  8. The assessment and treatment of performance anxiety in musicians.

    PubMed

    Clark, D B; Agras, W S

    1991-05-01

    Performance anxiety in musicians may be severe enough to require intervention but has been the subject of relatively little clinical research. The authors' objectives were to describe the results of a comprehensive clinical and laboratory assessment and to perform a double-blind, placebo-controlled study comparing buspirone, cognitive-behavior therapy, and the combination of these treatments for performance anxiety. Ninety-four subjects were recruited by mass media announcements and were seen in a university-based outpatient psychiatric clinic. Assessments were 1) questionnaires for all 94 subjects, 2) diagnostic interview of 50 subjects, and 3) laboratory performance of 34 subjects. Treatment conditions were 1) 6 weeks of buspirone, 2) 6 weeks of placebo, 3) a five-session, group cognitive-behavior therapy program with buspirone, or 4) the cognitive-behavior therapy program with placebo. Treatment outcome measures included subjective anxiety ratings and heart rate measures during a laboratory performance, a questionnaire measure of performance confidence, and a blind rating of musical performance quality. All subjects fulfilled criteria for DSM-III-R social phobia. Of the 15 full-time professional musicians, ten had tried propranolol and three had stopped performing. Most of the subjects had substantial anxiety and heart rate increases during laboratory speech and musical performances. Cognitive-behavior therapy resulted in statistically significant reductions in subjective anxiety, improved quality of musical performance, and improved performance confidence. Buspirone was not an effective treatment. Cognitive-behavior therapy is a viable treatment approach for performance anxiety in musicians.

  9. Hydrothermal Synthesis of Platinum-Group-Metal-Free Catalysts: Structural Elucidation and Oxygen Reduction Catalysis

    DOE PAGES

    Gokhale, Rohan; Tsui, Lok-Kun; Roach, Kristin; ...

    2017-12-07

    In this paper, a hydrothermal approach to generate a platinum-group-metal-free (PGM-free) Fe-N-C catalyst for the oxygen reduction reaction (ORR) is introduced. The process involves partial carbonization by hydrothermal means followed by thermal treatment to obtain the final catalysts. Detailed X-ray scattering analysis of the glucose-imidazole catalysts (termed as GLU-IMID-C catalysts), obtained for the first time with the use of CarbonXS GUI program, reveals the presence of face-centered cubic (FCC) iron nanoparticles embedded in partially graphitic carbon in all catalyst variations. We also report the physical characterization of these catalysts by using X-ray photoelectron spectroscopy, Brunauer-Emmett-Teller surface area analysis, and transmissionmore » electron microscopy. The electrocatalytic behavior of the catalysts towards oxygen reduction is studied separately in acidic and alkaline electrolytes by rotating ring disk electrode measurements. The catalysts exhibit high ORR activity in acidic (0.5 M H 2SO 4) and alkaline (0.1 M KOH) electrolytes. Lastly, a precursor structure-performance relationship of these catalysts and their performance trends in both electrolytes has been discussed in this work.« less

  10. Hydrothermal Synthesis of Platinum-Group-Metal-Free Catalysts: Structural Elucidation and Oxygen Reduction Catalysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gokhale, Rohan; Tsui, Lok-Kun; Roach, Kristin

    In this paper, a hydrothermal approach to generate a platinum-group-metal-free (PGM-free) Fe-N-C catalyst for the oxygen reduction reaction (ORR) is introduced. The process involves partial carbonization by hydrothermal means followed by thermal treatment to obtain the final catalysts. Detailed X-ray scattering analysis of the glucose-imidazole catalysts (termed as GLU-IMID-C catalysts), obtained for the first time with the use of CarbonXS GUI program, reveals the presence of face-centered cubic (FCC) iron nanoparticles embedded in partially graphitic carbon in all catalyst variations. We also report the physical characterization of these catalysts by using X-ray photoelectron spectroscopy, Brunauer-Emmett-Teller surface area analysis, and transmissionmore » electron microscopy. The electrocatalytic behavior of the catalysts towards oxygen reduction is studied separately in acidic and alkaline electrolytes by rotating ring disk electrode measurements. The catalysts exhibit high ORR activity in acidic (0.5 M H 2SO 4) and alkaline (0.1 M KOH) electrolytes. Lastly, a precursor structure-performance relationship of these catalysts and their performance trends in both electrolytes has been discussed in this work.« less

  11. Bearing Fault Diagnosis Based on Statistical Locally Linear Embedding

    PubMed Central

    Wang, Xiang; Zheng, Yuan; Zhao, Zhenzhou; Wang, Jinping

    2015-01-01

    Fault diagnosis is essentially a kind of pattern recognition. The measured signal samples usually distribute on nonlinear low-dimensional manifolds embedded in the high-dimensional signal space, so how to implement feature extraction, dimensionality reduction and improve recognition performance is a crucial task. In this paper a novel machinery fault diagnosis approach based on a statistical locally linear embedding (S-LLE) algorithm which is an extension of LLE by exploiting the fault class label information is proposed. The fault diagnosis approach first extracts the intrinsic manifold features from the high-dimensional feature vectors which are obtained from vibration signals that feature extraction by time-domain, frequency-domain and empirical mode decomposition (EMD), and then translates the complex mode space into a salient low-dimensional feature space by the manifold learning algorithm S-LLE, which outperforms other feature reduction methods such as PCA, LDA and LLE. Finally in the feature reduction space pattern classification and fault diagnosis by classifier are carried out easily and rapidly. Rolling bearing fault signals are used to validate the proposed fault diagnosis approach. The results indicate that the proposed approach obviously improves the classification performance of fault pattern recognition and outperforms the other traditional approaches. PMID:26153771

  12. Gallium Arsenide solar cell radiation damage experiment

    NASA Technical Reports Server (NTRS)

    Maurer, R. H.; Kinnison, J. D.; Herbert, G. A.; Meulenberg, A.

    1991-01-01

    Gallium arsenide (GaAs) solar cells for space applications from three different manufactures were irradiated with 10 MeV protons or 1 MeV electrons. The electrical performance of the cells was measured at several fluence levels and compared. Silicon cells were included for reference and comparison. All the GaAs cell types performed similarly throughout the testing and showed a 36 to 56 percent power areal density advantage over the silicon cells. Thinner (8-mil versus 12-mil) GaAs cells provide a significant weight reduction. The use of germanium (Ge) substrates to improve mechanical integrity can be implemented with little impact on end of life performance in a radiation environment.

  13. Nuclear thermal rocket nozzle testing and evaluation program

    NASA Technical Reports Server (NTRS)

    Davidian, Kenneth O.; Kacynski, Kenneth J.

    1993-01-01

    Performance characteristics of the Nuclear Thermal Rocket can be enhanced through the use of unconventional nozzles as part of the propulsion system. The Nuclear Thermal Rocket nozzle testing and evaluation program being conducted at the NASA Lewis is outlined and the advantages of a plug nozzle are described. A facility description, experimental designs and schematics are given. Results of pretest performance analyses show that high nozzle performance can be attained despite substantial nozzle length reduction through the use of plug nozzles as compared to a convergent-divergent nozzle. Pretest measurement uncertainty analyses indicate that specific impulse values are expected to be within + or - 1.17 pct.

  14. Effect of crystal size distribution on thermoelectric performance for Lanthanum-doped strontium titanate bulk material

    NASA Astrophysics Data System (ADS)

    Zhang, Boyu; Wang, Jun; Yaer, Xinba; Huo, Zhenzhen; Wu, Yin; Li, Yan; Miao, Lei; Liu, Chengyan; Zou, Tao; Ma, Wen

    2015-07-01

    Effect of crystal size distribution on thermoelectric performance of Lanthanum-doped strontium titanate (La-SrTiO3) ceramics are investigated in this study. Thermoelectric performance measurement, coupled with microstructure studies, shows that the electrical conductivity strongly depends on the crystal size, potential barrier on the grain boundary and porosity. Meantime, because the average potential barriers height are increased along with the reduction of crystal size, the Seebeck coefficients are increased by energy filtering effect at the large number of grain boundaries. As a result, by controlling of crystal size distribution, ZT value of La-SrTiO3 is improved.

  15. Cost-effectiveness analysis of risk-reduction measures to reach water safety targets.

    PubMed

    Lindhe, Andreas; Rosén, Lars; Norberg, Tommy; Bergstedt, Olof; Pettersson, Thomas J R

    2011-01-01

    Identifying the most suitable risk-reduction measures in drinking water systems requires a thorough analysis of possible alternatives. In addition to the effects on the risk level, also the economic aspects of the risk-reduction alternatives are commonly considered important. Drinking water supplies are complex systems and to avoid sub-optimisation of risk-reduction measures, the entire system from source to tap needs to be considered. There is a lack of methods for quantification of water supply risk reduction in an economic context for entire drinking water systems. The aim of this paper is to present a novel approach for risk assessment in combination with economic analysis to evaluate risk-reduction measures based on a source-to-tap approach. The approach combines a probabilistic and dynamic fault tree method with cost-effectiveness analysis (CEA). The developed approach comprises the following main parts: (1) quantification of risk reduction of alternatives using a probabilistic fault tree model of the entire system; (2) combination of the modelling results with CEA; and (3) evaluation of the alternatives with respect to the risk reduction, the probability of not reaching water safety targets and the cost-effectiveness. The fault tree method and CEA enable comparison of risk-reduction measures in the same quantitative unit and consider costs and uncertainties. The approach provides a structured and thorough analysis of risk-reduction measures that facilitates transparency and long-term planning of drinking water systems in order to avoid sub-optimisation of available resources for risk reduction. Copyright © 2010 Elsevier Ltd. All rights reserved.

  16. What is the impact of a clinically related readmission measure on the assessment of hospital performance?

    PubMed

    Khouri, Roger K; Hou, Hechuan; Dhir, Apoorv; Andino, Juan J; Dupree, James M; Miller, David C; Ellimoottil, Chad

    2017-11-28

    The Hospital Readmission Reduction Program (HRRP) penalizes hospitals for high all-cause unplanned readmission rates. Many have expressed concern that hospitals serving patient populations with more comorbidities, lower incomes, and worse self-reported health status may be disproportionately penalized by readmissions that are not clinically related to the index admission. The impact of including clinically unrelated readmissions on hospital performance is largely unknown. We sought to determine if a clinically related readmission measure would significantly alter the assessment of hospital performance. We analyzed Medicare claims for beneficiaries in Michigan admitted for pneumonia and joint replacement from 2011 to 2013. We compared each hospital's 30-day readmission rate using specifications from the HRRP's all-cause unplanned readmission measure to values calculated using a clinically related readmission measure. We found that the mean 30-day readmission rates were lower when calculated using the clinically related readmission measure (joint replacement: all-cause 5.8%, clinically related 4.9%, p < 0.001; pneumonia: all cause 12.5%, clinically related 11.3%, p < 0.001)). The correlation of hospital ranks using both methods was strong (joint replacement: 0.95 (p < 0.001), pneumonia: 0.90 (p < 0.001)). Our findings suggest that, while greater specificity may be achieved with a clinically related measure, clinically unrelated readmissions may not impact hospital performance in the HRRP.

  17. High-speed optical three-axis vector magnetometry based on nonlinear Hanle effect in rubidium vapor

    NASA Astrophysics Data System (ADS)

    Azizbekyan, Hrayr; Shmavonyan, Svetlana; Khanbekyan, Aleksandr; Movsisyan, Marina; Papoyan, Aram

    2017-07-01

    The magnetic-field-compensation optical vector magnetometer based on the nonlinear Hanle effect in alkali metal vapor allowing two-axis measurement operation has been further elaborated for three-axis performance, along with significant reduction of measurement time. The upgrade was achieved by implementing a two-beam resonant excitation configuration and a fast maximum searching algorithm. Results of the proof-of-concept experiments, demonstrating 1 μT B-field resolution, are presented. The applied interest and capability of the proposed technique is analyzed.

  18. Two-phase flow measurements with advanced instrumented spool pieces

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Turnage, K.C.

    1980-09-01

    A series of two-phase, air-water and steam-water tests performed with instrumented piping spool pieces is described. The behavior of the three-beam densitometer, turbine meter, and drag flowmeter is discussed in terms of two-phase models. Results from application of some two-phase mass flow models to the recorded spool piece data are shown. Results of the study are used to make recommendations regarding spool piece design, instrument selection, and data reduction methods to obtain more accurate measurements of two-phase flow parameters. 13 refs., 23 figs., 1 tab.

  19. Water-Gas Shift and Methane Reactivity on Reducible Perovskite-Type Oxides

    PubMed Central

    2015-01-01

    Comparative (electro)catalytic, structural, and spectroscopic studies in hydrogen electro-oxidation, the (inverse) water-gas shift reaction, and methane conversion on two representative mixed ionic–electronic conducting perovskite-type materials La0.6Sr0.4FeO3−δ (LSF) and SrTi0.7Fe0.3O3−δ (STF) were performed with the aim of eventually correlating (electro)catalytic activity and associated structural changes and to highlight intrinsic reactivity characteristics as a function of the reduction state. Starting from a strongly prereduced (vacancy-rich) initial state, only (inverse) water-gas shift activity has been observed on both materials beyond ca. 450 °C but no catalytic methane reforming or methane decomposition reactivity up to 600 °C. In contrast, when starting from the fully oxidized state, total methane oxidation to CO2 was observed on both materials. The catalytic performance of both perovskite-type oxides is thus strongly dependent on the degree/depth of reduction, on the associated reactivity of the remaining lattice oxygen, and on the reduction-induced oxygen vacancies. The latter are clearly more reactive toward water on LSF, and this higher reactivity is linked to the superior electrocatalytic performance of LSF in hydrogen oxidation. Combined electron microscopy, X-ray diffraction, and Raman measurements in turn also revealed altered surface and bulk structures and reactivities. PMID:26045733

  20. Interfacial Surface Modification via Nanoimprinting to Increase Open-Circuit Voltage of Organic Solar Cells

    NASA Astrophysics Data System (ADS)

    Emah, Joseph B.; George, Nyakno J.; Akpan, Usenobong B.

    2017-08-01

    The low-cost patterning of poly(3,4-ethylenedioxythiophene) poly(4-styrenesulfonate) (PEDOT:PSS) interfacial layers inserted between indium tin oxide and poly(3-hexylthiophene-2,5-diyl):[6,6]-phenyl-C61-butyric acid ester blends leads to an improvement in organic photovoltaics (OPV) device performance. Significantly, improvements in all device parameters, including the open-circuit voltage, are achieved. The nanoimprinted devices improved further as the pattern period and imprinting depth was reduced from 727 nm and 42 nm to 340 nm and 10 nm, respectively. A residue of poly(dimethylsiloxane) (PDMS) is found on the interfacial PEDOT:PSS film following patterning and can be used to explain the increase in OPV performance. Ultraviolet photoelectron spectroscopy measurements of the PEDOT:PSS interfacial layer demonstrated a reduction of the work function of 0.4 eV following nanoimprinting which may originate from chemical modification of the PDMS residue or interfacial dipole formation supported by x-ray photoelectron spectroscopy analysis. Ultimately, we have demonstrated a 39% improvement in OPV device performance via a simple low-cost modification of the anode interfacial layer. This improvement can be assigned to two effects resulting from a PDMS residue on the PEDOT:PSS surface: (1) the reduction of the anode work function which in turn decreases the hole extraction barrier, and (2) the reduction of electron transfer from the highest occupied molecular orbital of PCBM to the anode.

  1. Structural and functional changes of the cingulate gyrus following traumatic brain injury: relation to attention and executive skills.

    PubMed

    Merkley, Tricia L; Larson, Michael J; Bigler, Erin D; Good, Daniel A; Perlstein, William M

    2013-09-01

    Impairments of attention and executive functions are common sequelae of traumatic brain injury (TBI). The anterior cingulate is implicated in conflict-related task performance, such as the Stroop, and is susceptible to TBI-related injury due to its frontal location and proximity to the rough surface of the falx cerebri. We investigated the relationship between cingulate cortex volume and performance on tasks of selective attention and cognitive flexibility (single-trial Stroop and Auditory Consonant Trigrams [ACT]). Participants consisted of 12 adults with severe TBI and 18 controls. T1-weighted volumetric MRI data were analyzed using automated cortical reconstruction, segmentation, parcellation, and volume measurement. Cortical volume reductions were prominent bilaterally in frontal, temporal, and inferior parietal regions.Specific regional reduction of the cingulate cortex was observed only for cortical volume of right caudal anterior cingulate(cACC). The TBI group performed significantly worse than control participants on the Stroop and ACT tasks. Findings suggest that atrophy of the right cACC may contribute to reduced performance on executive function tasks, such as the Stroop and ACT, although this is likely but one node of an extensive brain network involved in these cognitive processes.

  2. Empennage Noise Shielding Benefits for an Open Rotor Transport

    NASA Technical Reports Server (NTRS)

    Berton, Jeffrey J.

    2012-01-01

    NASA sets aggressive, strategic, civil aircraft performance and environmental goals and develops ambitious technology roadmaps to guide its research efforts. NASA has adopted a phased approach for community noise reduction of civil aircraft. While the goal of the near-term first phase focuses primarily on source noise reduction, the goal of the second phase relies heavily on presumed architecture changes of future aircraft. The departure from conventional airplane configurations to designs that incorporate some type of propulsion noise shielding is anticipated to provide an additional 10 cumulative EPNdB of noise reduction. One candidate propulsion system for these advanced aircraft is the open rotor engine. In some planned applications, twin open rotor propulsors are located on the aft fuselage, with the vehicle s empennage shielding some of their acoustic signature from observers on the ground. This study focuses on predicting the noise certification benefits of a notional open rotor aircraft with tail structures shielding a portion of the rotor noise. The measured noise of an open rotor test article--collected with and without an acoustic barrier wall--is the basis of the prediction. The results are used to help validate NASA s reliance on acoustic shielding to achieve the second phase of its community noise reduction goals. The noise measurements are also compared to a popular empirical diffraction correlation often used at NASA to predict acoustic shielding.

  3. Cryolipolysis for Reduction of Arm Fat: Safety and Efficacy of a Prototype CoolCup Applicator With Flat Contour

    PubMed Central

    Humphrey, Shannon; Rivers, Jason K.

    2017-01-01

    BACKGROUND Cryolipolysis of the arms has been shown to be an effective but somewhat time-consuming process. OBJECTIVE The study evaluated safety and efficacy of a contoured cup cryolipolysis applicator for reduction of arm fat. The prototype was designed to maximize tissue contact with the cooling surface to improve comfort, while reducing treatment time by 25 minutes. MATERIALS AND METHODS Both arms were treated using a prototype device that delivered treatment in 35 minutes at −11°C. Photographic and ultrasound documentation was captured at baseline and 12 weeks post-treatment. Efficacy was assessed by photo review and measurement of fat reduction in ultrasound images. Immediately after 1, 4, and 12 weeks post-treatment, clinical assessments were performed to evaluate treatment areas and sensory alterations. RESULTS Thirty women were enrolled and completed treatments to both arms. Ultrasound measurements found mean fat layer reduction of 3.2 mm with an SD of 2.7 mm. Blinded independent photo review found 85.2% correct identification of baseline photographs by at least 2/3 of reviewers. There were no unanticipated adverse device effects. Four study subjects experienced numbness in the treatment area beyond the 12-week visit that subsequently resolved without intervention. CONCLUSION These data suggest that the CoolCup prototype applicator provides rapid, safe, and effective arm treatment. PMID:28595246

  4. Effect of Acupuncture on Body Weight Reduction and Inflammatory Mediators in Egyptian Obese Patients

    PubMed Central

    Ismail, Laila Ahmed Abou; Ibrahim, Alshaymaa Ahmed; Abdel-Latif, Ghada A.; El-Haleem, Dalia Adel Abd; Helmy, Ghada; Labib, Lylah M.; El-Masry, M. Kadry

    2015-01-01

    AIM: Aim of this study was to examine the effectiveness of body acupuncture on body weight loss, routine laboratory tests and pro-inflammatory markers. METHODOLOGY: The study was performed on eighty obese patients. They were divided into three groups according to their body mass index. Subjects received acupuncture for three- six months in combination with a low-calorie diet. They were assessed pre and post acupuncture, by anthropometric measurement, routine laboratory tests and, tumor necrosis factor- alpha (TNF-α), interleukin- 6 (IL-6), and high sensitivity C-reactive protein (hsCRP) levels in serum. RESULTS: The pre-acupuncture results showed significant difference between the three grades of obesity and the controls regarding TNFα, IL-6 and hsCRP. We found significant reduction in anthropometric measurement of adiposity after acupuncture. In comparing the pre &post acupuncture results of TNF-α, IL-6 and hsCRP showed high significant reduction after acupuncture. There are highly significant decrease in kidney function (creatinine and uric acid) and lipid profile (cholesterol and triglycerides) and fasting blood glucose, but there was no significant difference in urea, SGPT, SGOT, HDL and LDL. CONCLUSION: Body acupuncture in combination with diet restriction was found to be effective for weight loss and also reduction of the inflammatory reactions. Acupuncture could be used as a synergistic treatment option for obesity control. PMID:27275202

  5. Influence of the measurement location on the resistance index in the umbilical arteries: a hemodynamic approach.

    PubMed

    Vieyres, P; Durand, A; Patat, F; Descamps, P; Gregoire, J M; Pourcelot, D; Pourcelot, L

    1991-12-01

    A computer model was used to study the primary factors generating the reduction in resistance index, (S-D)/S, values observed by ultrasonic Doppler measurements in the umbilical artery, from the fetal insertion to the placental insertion (S represents the amplitude of the systolic peak and D the amplitude of the diastolic peak). This hemodynamic approach shows that the placental resistance is the primary factor, the viscosity and the cord length playing secondary roles. Clinically, the position of the measurement along the cord is an important factor. To increase the sensitivity of the index, the Doppler measurement must be performed near the fetal insertion, whereas a measurement near the placental insertion will make the Doppler examination more specific.

  6. Can we "predict" long-term outcome for ambulatory transcutaneous electrical nerve stimulation in patients with chronic pain?

    PubMed

    Köke, Albère J; Smeets, Rob J E M; Perez, Roberto S; Kessels, Alphons; Winkens, Bjorn; van Kleef, Maarten; Patijn, Jacob

    2015-03-01

    Evidence for effectiveness of transcutaneous electrical nerve stimulation (TENS) is still inconclusive. As heterogeneity of chronic pain patients might be an important factor for this lack of efficacy, identifying factors for a successful long-term outcome is of great importance. A prospective study was performed to identify variables with potential predictive value for 2 outcome measures on long term (6 months); (1) continuation of TENS, and (2) a minimally clinical important pain reduction of ≥ 33%. At baseline, a set of risk factors including pain-related variables, psychological factors, and disability was measured. In a multiple logistic regression analysis, higher patient's expectations, neuropathic pain, no severe pain (< 80 mm visual analogue scale [VAS]) were independently related to long-term continuation of TENS. For the outcome "minimally clinical important pain reduction," the multiple logistic regression analysis indicated that no multisited pain (> 2 pain locations) and intermittent pain were positively and independently associated with a minimally clinical important pain reduction of ≥ 33%. The results showed that factors associated with a successful outcome in the long term are dependent on definition of successful outcome. © 2014 World Institute of Pain.

  7. Acoustic-noise-optimized diffusion-weighted imaging.

    PubMed

    Ott, Martin; Blaimer, Martin; Grodzki, David M; Breuer, Felix A; Roesch, Julie; Dörfler, Arnd; Heismann, Björn; Jakob, Peter M

    2015-12-01

    This work was aimed at reducing acoustic noise in diffusion-weighted MR imaging (DWI) that might reach acoustic noise levels of over 100 dB(A) in clinical practice. A diffusion-weighted readout-segmented echo-planar imaging (EPI) sequence was optimized for acoustic noise by utilizing small readout segment widths to obtain low gradient slew rates and amplitudes instead of faster k-space coverage. In addition, all other gradients were optimized for low slew rates. Volunteer and patient imaging experiments were conducted to demonstrate the feasibility of the method. Acoustic noise measurements were performed and analyzed for four different DWI measurement protocols at 1.5T and 3T. An acoustic noise reduction of up to 20 dB(A) was achieved, which corresponds to a fourfold reduction in acoustic perception. The image quality was preserved at the level of a standard single-shot (ss)-EPI sequence, with a 27-54% increase in scan time. The diffusion-weighted imaging technique proposed in this study allowed a substantial reduction in the level of acoustic noise compared to standard single-shot diffusion-weighted EPI. This is expected to afford considerably more patient comfort, but a larger study would be necessary to fully characterize the subjective changes in patient experience.

  8. Delving into sensible measures to enhance the environmental performance of biohydrogen: A quantitative approach based on process simulation, life cycle assessment and data envelopment analysis.

    PubMed

    Martín-Gamboa, Mario; Iribarren, Diego; Susmozas, Ana; Dufour, Javier

    2016-08-01

    A novel approach is developed to evaluate quantitatively the influence of operational inefficiency in biomass production on the life-cycle performance of hydrogen from biomass gasification. Vine-growers and process simulation are used as key sources of inventory data. The life cycle assessment of biohydrogen according to current agricultural practices for biomass production is performed, as well as that of target biohydrogen according to agricultural practices optimised through data envelopment analysis. Only 20% of the vineyards assessed operate efficiently, and the benchmarked reduction percentages of operational inputs range from 45% to 73% in the average vineyard. The fulfilment of operational benchmarks avoiding irregular agricultural practices is concluded to improve significantly the environmental profile of biohydrogen (e.g., impact reductions above 40% for eco-toxicity and global warming). Finally, it is shown that this type of bioenergy system can be an excellent replacement for conventional hydrogen in terms of global warming and non-renewable energy demand. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. On the influence of high-pass filtering on ICA-based artifact reduction in EEG-ERP.

    PubMed

    Winkler, Irene; Debener, Stefan; Müller, Klaus-Robert; Tangermann, Michael

    2015-01-01

    Standard artifact removal methods for electroencephalographic (EEG) signals are either based on Independent Component Analysis (ICA) or they regress out ocular activity measured at electrooculogram (EOG) channels. Successful ICA-based artifact reduction relies on suitable pre-processing. Here we systematically evaluate the effects of high-pass filtering at different frequencies. Offline analyses were based on event-related potential data from 21 participants performing a standard auditory oddball task and an automatic artifactual component classifier method (MARA). As a pre-processing step for ICA, high-pass filtering between 1-2 Hz consistently produced good results in terms of signal-to-noise ratio (SNR), single-trial classification accuracy and the percentage of `near-dipolar' ICA components. Relative to no artifact reduction, ICA-based artifact removal significantly improved SNR and classification accuracy. This was not the case for a regression-based approach to remove EOG artifacts.

  10. Decrease of Nitrate Reductase Activity in Spinach Leaves during a Light-Dark Transition 1

    PubMed Central

    Riens, Burgi; Heldt, Hans Walter

    1992-01-01

    In leaves of spinach plants (Spinacia oleracea L.) performing CO2 and NO3− assimilation, at the time of sudden darkening, which eliminates photosystem I-dependent nitrite reduction, only a minor temporary increase of the leaf nitrite content is observed. Because nitrate reduction does not depend on redox equivalents generated by photosystem I activity, a continuation of nitrate reduction after darkening would result in a large accumulation of nitrite in the leaves within a very short time, which is not observed. Measurements of the extractable nitrate reductase activity from spinach leaves assayed under standard conditions showed that in these leaves the nitrate reductase activity decreased during darkening to 15% of the control value with a half-time of only 2 minutes. Apparently, in these leaves nitrate reductase is very rapidly inactivated at sudden darkness avoiding an accumulation of the toxic nitrite in the cells. PMID:16668679

  11. A comparative evaluation on the emission characteristics of ceramic and metallic catalytic converter in internal combustion engine

    NASA Astrophysics Data System (ADS)

    Leman, A. M.; Jajuli, Afiqah; Rahman, Fakhrurrazi; Feriyanto, Dafit; Zakaria, Supaat

    2017-09-01

    Enforcement of a stricter regulation on exhaust emission by many countries has led to utilization of catalytic converter to reduce the harmful pollutant emission. Ceramic and metallic catalytic converters are the most common type of catalytic converter used. The purpose of this study is to evaluate the performance of the ceramic and metallic catalytic converter on its conversion efficiency using experimental measurement. Both catalysts were placed on a modified exhaust system equipped with a Mitshubishi 4G93 single cylinder petrol engine that was tested on an eddy current dynamometer under steady state conditions for several engine speeds. The experimental results show that the metallic catalytic converter reduced a higher percentage of CO up to 98.6% reduction emissions while ceramic catalytic converter had a better reduction efficiency of HC up to 85.4% and 87.2% reduction of NOx.

  12. Acoustic Aspects of Active-Twist Rotor Control

    NASA Technical Reports Server (NTRS)

    Booth, Earl R., Jr.; Wilbur, Matthew L.

    2002-01-01

    The use of an Active Twist Rotor system to provide both vibration reduction and performance enhancement has been explored in recent analytical and experimental studies. Effects of active-twist control on rotor noise, however, had not been determined. During a recent wind tunnel test of an active-twist rotor system, a set of acoustic measurements were obtained to assess the effects of active-twist control on noise produced by the rotor, especially blade-vortex interaction (BVI) noise. It was found that for rotor operating conditions where BVI noise is dominant, active-twist control provided a reduction in BVI noise level. This BVI noise reduction was almost, but not quite, as large as that obtained in a similar test using HHC. However, vibration levels were usually adversely affected at operating conditions favoring minimum BVI noise. Conversely, operating conditions favoring minimum vibration levels affected BVI noise levels, but not always adversely.

  13. Pixel detectors in double beta decay experiments, a new approach for background reduction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jose, J. M.; Čermák, P.; Štekl, I.

    Double beta decay (ββ) experiments are challenging frontiers in contemporary physics. These experiments have the potential to investigate more about neutrinos (eg. nature and mass). The main challenge for these experiments is the reduction of background. The group at IEAP, CTU in Prague is investigating a new approach using pixel detectors Timepix. Pixel detector offer background reduction capabilities with its ability to identify the particle interaction (from the 2D signature it generates). However, use of pixel detectors has some challenges such as the presence of readout electronics near the sensing medium and heat dissipation. Different aspects of pixel setup (identificationmore » of radio-impurities, selection of radio-pure materials) and proposed experimental setup are presented. Also, results of preliminary background measurements (performed on the surface and in the underground laboratories) using the prototype setups are presented.« less

  14. A tailored workplace exercise program for women at risk for neck and upper limb musculoskeletal disorders: a randomized controlled trial.

    PubMed

    Rasotto, Chiara; Bergamin, Marco; Sieverdes, John C; Gobbo, Stefano; Alberton, Cristine L; Neunhaeuserer, Daniel; Maso, Stefano; Zaccaria, Marco; Ermolao, Andrea

    2015-02-01

    The aim of this study was to evaluate a tailored physical activity protocol performed in a work environment with a group of female workers employed in manual precision tasks to reduce upper limb pain. Sixty female subjects were randomly assigned to an intervention group or a control group. The IG was administered of a 6-month, twice-a-week, tailored exercise program, whereas the CG received no intervention. The IG showed a reduction on shoulder pain accompanied by increases on the range of motion measures. In addition, reductions in upper limb pain and neck disability were detected with concomitant increases in grip strength. This study indicated positive effects of a tailored workplace exercise protocol in female workers exposed to moderate risk for work-related musculoskeletal disorders, showing clinically meaningful reductions of pain symptoms and disability on upper limb and neck regions.

  15. Enema reduction of intussusception: the success rate of hydrostatic and pneumatic reduction.

    PubMed

    Khorana, Jiraporn; Singhavejsakul, Jesda; Ukarapol, Nuthapong; Laohapensang, Mongkol; Wakhanrittee, Junsujee; Patumanond, Jayanton

    2015-01-01

    Intussusception is a common surgical emergency in infants and children. The incidence of intussusception is from one to four per 2,000 infants and children. If there is no peritonitis, perforation sign on abdominal radiographic studies, and nonresponsive shock, nonoperative reduction by pneumatic or hydrostatic enema can be performed. The purpose of this study was to compare the success rates of both the methods. Two institutional retrospective cohort studies were performed. All intussusception patients (ICD-10 code K56.1) who had visited Chiang Mai University Hospital and Siriraj Hospital from January 2006 to December 2012 were included in the study. The data were obtained by chart reviews and electronic databases, which included demographic data, symptoms, signs, and investigations. The patients were grouped according to the method of reduction followed into pneumatic reduction and hydrostatic reduction groups with the outcome being the success of the reduction technique. One hundred and seventy episodes of intussusception occurring in the patients of Chiang Mai University Hospital and Siriraj Hospital were included in this study. The success rate of pneumatic reduction was 61% and that of hydrostatic reduction was 44% (P=0.036). Multivariable analysis and adjusting of the factors by propensity scores were performed; the success rate of pneumatic reduction was 1.48 times more than that of hydrostatic reduction (P=0.036, 95% confidence interval [CI] =1.03-2.13). Both pneumatic and hydrostatic reduction can be performed safely according to the experience of the radiologist or pediatric surgeon and hospital setting. This study showed that pneumatic reduction had a higher success rate than hydrostatic reduction.

  16. Matter over mind: a randomised-controlled trial of single-session biofeedback training on performance anxiety and heart rate variability in musicians.

    PubMed

    Wells, Ruth; Outhred, Tim; Heathers, James A J; Quintana, Daniel S; Kemp, Andrew H

    2012-01-01

    Musical performance is a skilled activity performed under intense pressure, thus is often a profound source of anxiety. In other contexts, anxiety and its concomitant symptoms of sympathetic nervous system arousal have been successfully ameliorated with HRV biofeedback (HRV BF), a technique involving slow breathing which augments autonomic and emotional regulatory capacity. This randomised-controlled study explored the impact of a single 30-minute session of HRV BF on anxiety in response to a highly stressful music performance. A total of 46 trained musicians participated in this study and were randomly allocated to a slow breathing with or without biofeedback or no-treatment control group. A 3 Group×2 Time mixed experimental design was employed to compare the effect of group before and after intervention on performance anxiety (STAI-S) and frequency domain measures of HRV. Slow breathing groups (n=30) showed significantly greater improvements in high frequency (HF) and LF/HF ratio measures of HRV relative to control (n=15) during 5 minute recordings of performance anticipation following the intervention (effect size: η(2) =0.122 and η(2) =0.116, respectively). The addition of biofeedback to a slow breathing protocol did not produce differential results. While intervention groups did not exhibit an overall reduction in self-reported anxiety, participants with high baseline anxiety who received the intervention (n=15) displayed greater reductions in self-reported state anxiety relative to those in the control condition (n=7) (r=0.379). These findings indicate that a single session of slow breathing, regardless of biofeedback, is sufficient for controlling physiological arousal in anticipation of psychosocial stress associated with music performance and that slow breathing is particularly helpful for musicians with high levels of anxiety. Future research is needed to further examine the effects of HRV BF as a low-cost, non-pharmacological treatment for music performance anxiety.

  17. Multifuctional integrated sensors (MFISES).

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Homeijer, Brian D.; Roozeboom, Clifton

    2015-10-01

    Many emerging IoT applications require sensing of multiple physical and environmental parameters for: completeness of information, measurement validation, unexpected demands, improved performance. For example, a typical outdoor weather station measures temperature, humidity, barometric pressure, light intensity, rainfall, wind speed and direction. Existing sensor technologies do not directly address the demand for cost, size, and power reduction in multi-paramater sensing applications. Industry sensor manufacturers have developed integrated sensor systems for inertial measurements that combine accelerometers, gyroscopes, and magnetometers, but do not address environmental sensing functionality. In existing research literature, a technology gap exists between the functionality of MEMS sensors and themore » real world applications of the sensors systems.« less

  18. 18-Degree-of-Freedom Controller Design for the ST7 Disturbance Reduction System

    NASA Technical Reports Server (NTRS)

    Markley, F. L.; Maghami, P. G.; Houghton, M. B.; Hsu, O. C.

    2003-01-01

    The Space Technology 7 experiment will perform an on-orbit system-level validation of a Disturbance Reduction System employing gravitational reference sensors and micronewton colloidal thrusters to maintain a spacecraft s position with respect to free-floating test masses in the gravitational reference sensors to less than 10 nm/dHz over the frequency range 1 to 30 mHz. This paper presents the design and analysis of the control system that closes the loop between the gravitational reference sensors and the micronewton thrusters while incorporating star tracker data at low frequencies. The effects of disturbances and actuation and measurement noise are evaluated in a eighteen-degree-of-freedom model.

  19. Photogeneration of hydrogen from water by a robust dye-sensitized photocathode

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shan, B.; Das, A. K.; Marquard, S.

    2016-11-15

    We report here on a novel photocathode with a “donor-dye-catalyst” assembly structure for water reduction. The photoelectrocatalytic performance of the photocathode under mild conditions, with a photocurrent of -56 μA/cm2 and a Faradaic yield of 53%, is superior relative to other reported photocathodes with surface attached molecular catalysts. Detailed electron transfer analyses, based on transient absorption measurements, show that the successful application of this photocathode originates mainly from the slow back electron transfer following light excitation. The results also demonstrate that addition of the long-chain assembly to the macro-mesoporous electrode surface plays a fundamental role in providing sufficient catalyst formore » water reduction.« less

  20. An investigation of angular stiffness and damping coefficients of an axial spline coupling in high-speed rotating machinery

    NASA Technical Reports Server (NTRS)

    Ku, C.-P. Roger; Walton, James F., Jr.; Lund, Jorgen W.

    1994-01-01

    This paper provided an opportunity to quantify the angular stiffness and equivalent viscous damping coefficients of an axial spline coupling used in high-speed turbomachinery. A unique test methodology and data reduction procedures were developed. The bending moments and angular deflections transmitted across an axial spline coupling were measured while a nonrotating shaft was excited by an external shaker. A rotor dynamics computer program was used to simulate the test conditions and to correlate the angular stiffness and damping coefficients. In addition, sensitivity analyses were performed to show that the accuracy of the dynamic coefficients do not rely on the accuracy of the data reduction procedures.

Top