NASA Technical Reports Server (NTRS)
Hashemi-Kia, Mostafa; Toossi, Mostafa
1990-01-01
A computational procedure for the reduction of large finite element models was developed. This procedure is used to obtain a significantly reduced model while retaining the essential global dynamic characteristics of the full-size model. This reduction procedure is applied to the airframe finite element model of AH-64A Attack Helicopter. The resulting reduced model is then validated by application to a vibration reduction study.
Arnaudon, Alexis; López, Marco Castrillón; Holm, Darryl D
2018-01-01
The un-reduction procedure introduced previously in the context of classical mechanics is extended to covariant field theory. The new covariant un-reduction procedure is applied to the problem of shape matching of images which depend on more than one independent variable (for instance, time and an additional labelling parameter). Other possibilities are also explored: nonlinear [Formula: see text]-models and the hyperbolic flows of curves.
Reduction of soil erosion on forest roads
Edward R. Burroughs; John G. King
1989-01-01
Presents the expected reduction in surface erosion from selected treatments applied to forest road traveledways, cutslopes, fillslopes, and ditches. Estimated erosion reduction is expressed as functions of ground cover, slope gradient, and soil properties whenever possible. A procedure is provided to select rock riprap size for protection of the road ditch.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rubin, H.; Bemporad, G.A.
This manuscript concerns the possible improvement of the conventional solar pond (CSP) performance by applying a multiselective injection and withdrawal procedure. The authors apply the term advanced solar pond (ASP), for a solar pond (SP) in which such a procedure is applied. The multiselective injection and withdrawal procedure creates in the SP a stratified thermal layer, namely a flowing layer which is subject to salinity and temperature stratification. This phenomenon is associated with reduction of heat losses into the atmosphere and an increase of the temperature of the fluid layer adjacent to the SP bottom. In the framework of thismore » study transport phenomena in the ASP are analyzed and simulated by applying a simplified mathematical model. The analysis and simulations indicate that the multiselective and withdrawal procedure may significantly improve the performance of the SP.« less
NASA Technical Reports Server (NTRS)
Peterson, R. C.; Title, A. M.
1975-01-01
A total reduction procedure, notable for its use of a computer-controlled microdensitometer for semi-automatically tracing curved spectra, is applied to distorted high-dispersion echelle spectra recorded by an image tube. Microdensitometer specifications are presented and the FORTRAN, TRACEN and SPOTS programs are outlined. The intensity spectrum of the photographic or electrographic plate is plotted on a graphic display. The time requirements are discussed in detail.
Battilocchio, Claudio; Hawkins, Joel M; Ley, Steven V
2013-05-03
A flow chemistry Meerwein-Ponndorf-Verley (MPV) reduction procedure using partially hydrated zirconium oxide via a machine-assisted approach is reported. The heterogeneous reductive system could be applied to a wide range of functionalized substrates, allowing clean and fast delivery of the alcohol products within a few minutes (6-75 min). In three examples the system was scaled to deliver 50 mmol of product.
Code of Federal Regulations, 2010 CFR
2010-10-01
... of reduction to the APC payment. (1) The amount of the reduction to the APC payment made under... be applied if the device implanted during a procedure assigned to the APC had transitional pass-through status under § 419.66. (2) The amount of the reduction to the APC payment made under paragraph (a...
Performance-based, cost- and time-effective pcb analytical methodology.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alvarado, J. S.
1998-06-11
Laboratory applications for the analysis of PCBs (polychlorinated biphenyls) in environmental matrices such as soil/sediment/sludge and oil/waste oil were evaluated for potential reduction in waste, source reduction, and alternative techniques for final determination. As a consequence, new procedures were studied for solvent substitution, miniaturization of extraction and cleanups, minimization of reagent consumption, reduction of cost per analysis, and reduction of time. These new procedures provide adequate data that meet all the performance requirements for the determination of PCBs. Use of the new procedures reduced costs for all sample preparation techniques. Time and cost were also reduced by combining the newmore » sample preparation procedures with the power of fast gas chromatography. Separation of Aroclor 1254 was achieved in less than 6 min by using DB-1 and SPB-608 columns. With the greatly shortened run times, reproducibility can be tested quickly and consequently with low cost. With performance-based methodology, the applications presented here can be applied now, without waiting for regulatory approval.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-06-08
Laboratory applications for the analysis of PCBS (polychlorinated biphenyls) in environmental matrices such as soil/sediment/sludge and oil/waste oil were evaluated for potential reduction in waste, source reduction, and alternative techniques for final determination. As a consequence, new procedures were studied for solvent substitution, miniaturization of extraction and cleanups, minimization of reagent consumption, reduction of cost per analysis, and reduction of time. These new procedures provide adequate data that meet all the performance requirements for the determination of PCBS. Use of the new procedures reduced costs for all sample preparation techniques. Time and cost were also reduced by combining the newmore » sample preparation procedures with the power of fast gas chromatography. Separation of Aroclor 1254 was achieved in less than 6 min by using DB-1 and SPB-608 columns. With the greatly shortened run times, reproducibility can be tested quickly and consequently with low cost. With performance-based methodology, the applications presented here can be applied now, without waiting for regulatory approval.« less
van der Wel, C M; Kortschot, R J; Bakelaar, I A; Erné, B H; Kuipers, B W M
2013-03-01
The sensitivity of an imperfectly balanced impedance bridge is limited by the remaining offset voltage. Here, we present a procedure for offset reduction in impedance measurements using a lock-in amplifier, by applying a complex compensating voltage external to the bridge. This procedure takes into account instrumental damping and phase shifting, which generally occur at the high end of the operational frequency range. Measurements demonstrate that the output of the circuit rapidly converges to the instrumentally limited noise at any frequency.
Kącka, Katarzyna; Kącki, Wojciech; Merak, Joanna; Błęka, Adam
2010-01-01
Planned surgical procedures at patients who refuse allogenic blood transfusion because of religious convictions are important problem, not only medical but also ethical and juristical. At the study authors report the successful use of activated recombinant factor VII (rFVIIa) for the reduction of perioperative blood loss in four years old child - Jehovah's Witness, who had planned Torode kyphectomy. Applied perioperative management together with preparing to surgery with erythropoietin allowed for reduction of blood loss and avoiding of blood transfusion. Authors state, that appropriate perioperative proceeding makes a possibility of safe surgical procedures also at patients who refuse the transfusion.
Identification of Noise Sources and Design of Noise Reduction Measures for a Pneumatic Nail Gun
Jayakumar, Vignesh; Zechmann, Edward
2015-01-01
An experimental-analytical procedure was implemented to reduce the operating noise level of a nail gun, a commonly found power tool in a construction site. The procedure is comprised of preliminary measurements, identification and ranking of major noise sources and application of noise controls. Preliminary measurements show that the impact noise transmitted through the structure and the exhaust related noise were found to be the first and second major contributors. Applying a noise absorbing foam on the outside of the nail gun body was found to be an effective noise reduction technique. One and two-volume small mufflers were designed and applied to the exhaust side of the nail gun which reduced not only the exhaust noise but also the impact noise. It was shown that the overall noise level could be reduced by as much as 3.5 dB, suggesting that significant noise reduction is possible in construction power tools without any significant increase of the cost. PMID:26366038
[Conversional and endoscopic procedures following bariatric surgery].
Zorron, R; Bothe, C; Junghans, T; Pratschke, J; Benzing, C; Krenzien, F
2016-10-01
The Roux-en-Y gastric bypass (RYGB) is the therapy of choice in bariatric surgery. Sleeve gastrectomy and gastric banding are showing higher rates of treatment failure, reducing obesity-associated morbidity and body weight insufficiently. Moreover, gastroesophageal reflux disease (GERD) can occur refractory to medication. Therefore, a laparoscopic conversion to RYGB can be reasonable as long as specific conditions are fulfilled.Endoscopic procedures are currently being applied to revise bariatric procedures. Therapy failure following RYGB occurs in up to 20 % of cases. Transoral outlet reduction is the minimally invasive method of choice to reduce gastrojejunal anastomosis of the alimentary limb. The diameter of a gastric sleeve can be unwantedly enlarged as well; that can be reduced by placement of a longitudinal full-thickness suture.Severe hypoglycemic episodes can be present in patients following RYGB. Hypoglycemic episodes have to be diagnosed first and can be treated conventionally. Alternatively, a laparoscopic approach according to Branco-Zorron can be used for non-responders. Hypoglycemic episodes can thus be prevented and body weight reduction can be assured.Conversional and endoscopic procedures can be used in patients with treatment failure following bariatric surgery. Note that non-invasive approaches should have been applied intensively before a revisional procedure is performed.
Model reduction in a subset of the original states
NASA Technical Reports Server (NTRS)
Yae, K. H.; Inman, D. J.
1992-01-01
A model reduction method is investigated to provide a smaller structural dynamic model for subsequent structural control design. A structural dynamic model is assumed to be derived from finite element analysis. It is first converted into the state space form, and is further reduced by the internal balancing method. Through the co-ordinate transformation derived from the states that are deleted during reduction, the reduced model is finally expressed with the states that are members of the original states. Therefore, the states in the final reduced model represent the degrees of freedom of the nodes that are selected by the designer. The procedure provides a more practical implementation of model reduction for applications in which specific nodes, such as sensor and/or actuator attachment points, are to be retained in the reduced model. Thus, it ensures that the reduced model is under the same input and output condition as the original physical model. The procedure is applied to two simple examples and comparisons are made between the full and reduced order models. The method can be applied to a linear, continuous and time-invariant model of structural dynamics with nonproportional viscous damping.
Stidd, D A; Theessen, H; Deng, Y; Li, Y; Scholz, B; Rohkohl, C; Jhaveri, M D; Moftakhar, R; Chen, M; Lopes, D K
2014-01-01
Flat panel detector CT images are degraded by streak artifacts caused by radiodense implanted materials such as coils or clips. A new metal artifacts reduction prototype algorithm has been used to minimize these artifacts. The application of this new metal artifacts reduction algorithm was evaluated for flat panel detector CT imaging performed in a routine clinical setting. Flat panel detector CT images were obtained from 59 patients immediately following cerebral endovascular procedures or as surveillance imaging for cerebral endovascular or surgical procedures previously performed. The images were independently evaluated by 7 physicians for metal artifacts reduction on a 3-point scale at 2 locations: immediately adjacent to the metallic implant and 3 cm away from it. The number of visible vessels before and after metal artifacts reduction correction was also evaluated within a 3-cm radius around the metallic implant. The metal artifacts reduction algorithm was applied to the 59 flat panel detector CT datasets without complications. The metal artifacts in the reduction-corrected flat panel detector CT images were significantly reduced in the area immediately adjacent to the implanted metal object (P = .05) and in the area 3 cm away from the metal object (P = .03). The average number of visible vessel segments increased from 4.07 to 5.29 (P = .1235) after application of the metal artifacts reduction algorithm to the flat panel detector CT images. Metal artifacts reduction is an effective method to improve flat panel detector CT images degraded by metal artifacts. Metal artifacts are significantly decreased by the metal artifacts reduction algorithm, and there was a trend toward increased vessel-segment visualization. © 2014 by American Journal of Neuroradiology.
NASA Astrophysics Data System (ADS)
Furlong, Cosme; Pryputniewicz, Ryszard J.
2002-06-01
Effective suppression of speckle noise content in interferometric data images can help in improving accuracy and resolution of the results obtained with interferometric optical metrology techniques. In this paper, novel speckle noise reduction algorithms based on the discrete wavelet transformation are presented. The algorithms proceed by: (a) estimating the noise level contained in the interferograms of interest, (b) selecting wavelet families, (c) applying the wavelet transformation using the selected families, (d) wavelet thresholding, and (e) applying the inverse wavelet transformation, producing denoised interferograms. The algorithms are applied to the different stages of the processing procedures utilized for generation of quantitative speckle correlation interferometry data of fiber-optic based opto-electronic holography (FOBOEH) techniques, allowing identification of optimal processing conditions. It is shown that wavelet algorithms are effective for speckle noise reduction while preserving image features otherwise faded with other algorithms.
Earplug rankings based on the protector-attenuation rating (P-AR).
DOT National Transportation Integrated Search
1975-01-01
Forty-five attenuation spectra for earplugs were classified according to a simplified method designed to produce single-number ratings of noise reduction. The rating procedure was applied to the mean attenuation scores, to mean-minus-one-standard-dev...
NASA Technical Reports Server (NTRS)
Pritchard, Jocelyn I.; Adelman, Howard M.; Walsh, Joanne L.; Wilbur, Matthew L.
1992-01-01
The development and validation of an optimization procedure to systematically place tuning masses along a rotor blade span to minimize vibratory loads are described. The masses and their corresponding locations are the design variables that are manipulated to reduce the harmonics of hub shear for a four-bladed rotor system without adding a large mass penalty. The procedure incorporates a comprehensive helicopter analysis to calculate the airloads. Predicting changes in airloads due to changes in design variables is an important feature of this research. The procedure was applied to a one-sixth, Mach-scaled rotor blade model to place three masses and then again to place six masses. In both cases the added mass was able to achieve significant reductions in the hub shear. In addition, the procedure was applied to place a single mass of fixed value on a blade model to reduce the hub shear for three flight conditions. The analytical results were compared to experimental data from a wind tunnel test performed in the Langley Transonic Dynamics Tunnel. The correlation of the mass location was good and the trend of the mass location with respect to flight speed was predicted fairly well. However, it was noted that the analysis was not entirely successful at predicting the absolute magnitudes of the fixed system loads.
Larson, Reed T; Samant, Andrew; Chen, Jianbin; Lee, Woojin; Bohn, Martin A; Ohlmann, Dominik M; Zuend, Stephan J; Toste, F Dean
2017-10-11
The development of a system for the operationally simple, scalable conversion of polyhydroxylated biomass into industrially relevant feedstock chemicals is described. This system includes a bimetallic Pd/Re catalyst in combination with hydrogen gas as a terminal reductant and enables the high-yielding reduction of sugar acids. This procedure has been applied to the synthesis of adipate esters, precursors for the production of Nylon-6,6, in excellent yield from biomass-derived sources.
Sleeve Expansion of Bolt Holes in Railroad Rail : Volume II, Process Parameters and Procedures
DOT National Transportation Integrated Search
1980-02-01
The bolt-hole cold-expansion process has been applied to railroad rail in laboratory tests and has demonstrated a potential for the reduction of rail-bolt-hole-failure incidence. Limited field tests also have been conducted and are currently under lo...
Code of Federal Regulations, 2011 CFR
2011-07-01
... Administration DEPARTMENT OF JUSTICE (CONTINUED) PROCEDURES FOR THE ADMINISTRATION OF SECTION 5 OF THE VOTING RIGHTS ACT OF 1965, AS AMENDED Contents of Submissions § 51.26 General. (a) The source of any information... Management and Budget control number under the Paperwork Reduction Act applies to the collection of...
Code of Federal Regulations, 2010 CFR
2010-07-01
... Administration DEPARTMENT OF JUSTICE (CONTINUED) PROCEDURES FOR THE ADMINISTRATION OF SECTION 5 OF THE VOTING RIGHTS ACT OF 1965, AS AMENDED Contents of Submissions § 51.26 General. (a) The source of any information... Management and Budget control number under the Paperwork Reduction Act applies to the collection of...
Calibrating a tensor magnetic gradiometer using spin data
Bracken, Robert E.; Smith, David V.; Brown, Philip J.
2005-01-01
Scalar magnetic data are often acquired to discern characteristics of geologic source materials and buried objects. It is evident that a great deal can be done with scalar data, but there are significant advantages to direct measurement of the magnetic gradient tensor in applications with nearby sources, such as unexploded ordnance (UXO). To explore these advantages, we adapted a prototype tensor magnetic gradiometer system (TMGS) and successfully implemented a data-reduction procedure. One of several critical reduction issues is the precise determination of a large group of calibration coefficients for the sensors and sensor array. To resolve these coefficients, we devised a spin calibration method, after similar methods of calibrating space-based magnetometers (Snare, 2001). The spin calibration procedure consists of three parts: (1) collecting data by slowly revolving the sensor array in the Earth?s magnetic field, (2) deriving a comprehensive set of coefficients from the spin data, and (3) applying the coefficients to the survey data. To show that the TMGS functions as a tensor gradiometer, we conducted an experimental survey that verified that the reduction procedure was effective (Bracken and Brown, in press). Therefore, because it was an integral part of the reduction, it can be concluded that the spin calibration was correctly formulated with acceptably small errors.
NASA Astrophysics Data System (ADS)
Furió, C.; Calatayud, M. L.; Bárcenas, S. L.; Padilla, O. M.
2000-09-01
Many of the learning difficulties in the specific domain of chemistry are found not only in the ideas already possessed by students but in the strategic and procedural knowledge that is characteristic of everyday thinking. These defects in procedural knowledge have been described as functional fixedness and functional reduction. This article assesses the procedural difficulties of students (grade 12 and first and third year of university) based on common sense reasoning in two areas of chemistry: chemical equilibrium and geometry and polarity of molecules. In the first area, the theme of external factors affecting equilibria (temperature and concentration change) was selected because the explanations given by the students could be analyzed easily. The existence of a functional fixedness where Le Chatelier's principle was almost exclusively applied by rote could be observed, with this being the cause of the incorrect responses given to the proposed items. Functional fixedness of the Lewis structure also led to an incorrect prediction of molecular geometry. When molecular geometry was correctly determined by the students, it seemed that other methodological or procedural difficulties appeared when the task was to determine molecular polarity. The students showed a tendency, in many cases, to reduce the factors affecting molecular polarity in two possible ways: (a) assuming that polarity depends only on shape (geometric functional reduction) or (b) assuming that molecular polarity depends only on the polarity of bonds (bonding functional reduction).
Visser, M; Stephan, D; Jaynes, J M; Burger, J T
2012-06-01
Natural and synthetic antimicrobial peptides (AMPs) are of increasing interest as potential resistance conferring elements in plants against pathogen infection. The efficacy of AMPs against pathogens is prescreened by in vitro assays, and promising AMP candidates are introduced as transgenes into plants. As in vitro and in planta environments differ, a prescreening procedure of the AMP efficacy in the plant environment is desired. Here, we report the efficacy of the purified synthetic peptide D4E1 against the grapevine-infecting bacterial pathogens Agrobacterium vitis and Xylophilus ampelinus in vitro and describe for the first time an in planta prescreening procedure based on transiently expressed D4E1. The antimicrobial effect of D4E1 against Ag. vitis and X. ampelinus was shown by a reduction in colony-forming units in vitro in a traditional plate-based assay and by a reduction in bacterial titres in planta as measured by quantitative real-time PCR (qPCR) in grapevine leaves transiently expressing D4E1. A statistically significant reduction in titre was shown for X. ampelinus, but for Ag. vitis, a significant reduction in titre was only observed in a subset of plants. The titres of both grapevine-infecting bacterial pathogens were reduced in an in vitro assay and for X. ampelinus in an in planta assay by D4E1 application. This widens the applicability of D4E1 as a potential resistance-enhancing element to additional pathogens and in a novel plant species. D4E1 is a promising candidate to confer enhanced resistance against the two tested grapevine bacterial pathogens, and the applied transient expression system proved to be a valuable tool for prescreening of D4E1 efficacy in an in planta environment. The described prescreening procedure can be used for other AMPs and might be adapted to other plant species and pathogens before the expensive and tedious development of stably transgenic lines is started. © 2012 The Authors. Letters in Applied Microbiology © 2012 The Society for Applied Microbiology.
Technical note: Signal resolution increase and noise reduction in a CCD digitizer.
González, A; Martínez, J A; Tobarra, B
2004-03-01
Increasing output resolution is assumed to improve noise characteristics of a CCD digitizer. In this work, however, we have found that as the quantization step becomes lower than the analog noise (present in the signal before its conversion to digital) the noise reduction becomes significantly lower than expected. That is the case for values of sigma(an)/delta larger than 0.6, where sigma(an) is the standard deviation of the analog noise and delta is the quantization step. The procedure is applied to a commercially available CCD digitizer, and noise reduction by means of signal resolution increase is compared to that obtained by low pass filtering.
Kyriakides, Rena; Jones, Patrick; Geraghty, Robert; Skolarikos, Andreas; Liatsikos, Evangellos; Traxer, Olivier; Pietropaolo, Amelia; Somani, Bhaskar K
2018-05-01
Music is a practical, inexpensive and harmless analgesic and anxiolytic. An increasing number of original studies have been performed to investigate its potential application in urology. Our aim was to identify the effect of music on outpatient based urological procedures. We systematically reviewed the effect of using music during all reported outpatient urology procedures, including transrectal ultrasound guided prostate biopsy, shock wave lithotripsy, urodynamic studies, percutaneous nephrostomy tube placement and cystoscopy. Data were included on all randomized trials from 1980 to 2017 and no language restrictions were applied. Included in analysis were 16 randomized studies in which 972 of 1,950 patients (49.8%) were exposed to music during an outpatient procedure. The procedures included transrectal ultrasound guided prostate biopsy in 4 studies in a total of 286 patients, shock wave lithotripsy in 6 studies in a total of 1,023, cystoscopy in 3 studies in a total of 331, urodynamics in 2 studies in a total of 210 and percutaneous nephrostomy in 1 study in a total of 100. All studies incorporated a visual analog score to measure pain. Anxiety was measured by STAI (State-Trait Anxiety Inventory) in 13 studies and by a visual analog scale in 2. While 14 of the 16 studies showed a reduction in self-reported pain, a reduction in anxiety was seen in 14. When using music, overall procedural satisfaction was better in 9 studies and patient willingness to repeat the procedure was also higher in 7. Our meta-analysis revealed a significant reduction in visual analog scale and STAI findings across all studies (p <0.001). Our systematic review demonstrated a beneficial effect of music on urological outpatient procedures. Music seemed to decrease anxiety and pain. It might serve as a useful adjunct to increase procedural satisfaction and patient willingness to undergo the procedure again. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
van Tilburg, C W J; Stronks, D L; Groeneweg, J G; Huygen, F J P M
2017-03-01
Investigate the effect of percutaneous radiofrequency compared to a sham procedure, applied to the ramus communicans for treatment of lumbar disc pain. Randomized sham-controlled, double-blind, crossover, multicenter clinical trial. Multidisciplinary pain centres of two general hospitals. Sixty patients aged 18 or more with medical history and physical examination suggestive for lumbar disc pain and a reduction of two or more on a numerical rating scale (0-10) after a diagnostic ramus communicans test block. Treatment group: percutaneous radiofrequency treatment applied to the ramus communicans; sham: same procedure except radiofrequency treatment. pain reduction. Secondary outcome measure: Global Perceived Effect. No statistically significant difference in pain level over time between the groups, as well as in the group was found; however, the factor period yielded a statistically significant result. In the crossover group, 11 out of 16 patients experienced a reduction in NRS of 2 or more at 1 month (no significant deviation from chance). No statistically significant difference in satisfaction over time between the groups was found. The independent factors group and period also showed no statistically significant effects. The same applies to recovery: no statistically significant effects were found. The null hypothesis of no difference in pain reduction and in Global Perceived Effect between the treatment and sham group cannot be rejected. Post hoc analysis revealed that none of the investigated parameters contributed to the prediction of a significant pain reduction. Interrupting signalling through the ramus communicans may interfere with the transition of painful information from the discs to the central nervous system. Methodological differences exist in studies evaluating the efficacy of radiofrequency treatment for lumbar disc pain. A randomized, sham-controlled, double-blind, multicenter clinical trial on the effect of radiofrequency at the ramus communicans for lumbar disc pain was conducted. The null hypothesis of no difference in pain reduction and in Global Perceived Effect between the treatment and sham group cannot be rejected. © 2016 The Authors. European Journal of Pain published by John Wiley & Sons Ltd on behalf of European Pain Federation - EFIC®.
A novel atrial volume reduction technique to enhance the Cox maze procedure: initial results.
Marui, Akira; Nishina, Takeshi; Tambara, Keiichi; Saji, Yoshiaki; Shimamoto, Takeshi; Nishioka, Masahiko; Ikeda, Tadashi; Komeda, Masashi
2006-11-01
Large left atrial diameter is reported to be a predictor for recurrent atrial fibrillation after the Cox maze procedure, and left atrial diameter by itself influences the chance of sinus rhythm recovery, as well as maintenance of sinus rhythm. However, additional cut-and-sew procedures to decrease left atrial diameter extend operative time and can cause bleeding. Thus we developed a no-bleeding, faster, and therefore less invasive left atrial volume reduction technique to enhance the Cox maze procedure. The modified Cox maze III procedure with cryoablation or the left atrial maze procedure in association with mitral valve surgery was performed in 80 patients with atrial fibrillation and enlarged left atria (> or =60 mm). Among them, 44 patients had the concomitant volume reduction technique (VR group); continuous horizontal mattress sutures for left atrial plication were placed on the left atrial wall along the pulmonary vein isolation line. Cryoablation was applied to the suture line so that the plicated left atrium is anatomically and electrically isolated. Another 36 patients did not have the volume reduction technique (control group). The VR group had preoperative left atrial diameters similar to those of the control group (67.1 +/- 7.8 vs 64.5 +/- 6.7 mm) and a longer preoperative duration of atrial fibrillation (14.1 +/- 5.4 vs 9.5 +/- 5.1 years, P < .05) but had smaller postoperative left atrial diameters (47.6 +/- 6.3 vs 62.1 +/- 7.9 mm, P < .01). There were no differences in mean crossclamp/bypass time and chest tube drainage for 12 hours between the groups. Twelve months after surgical intervention, the sinus rhythm recovery rate of the VR group was better than that of the control group (90% vs 69%, P < .05). Even in patients with long-standing atrial fibrillation and an enlarged left atrium, maze procedures concomitant with the novel left atrial volume reduction technique improved the sinus rhythm recovery rate without increasing complications. Although further study with a larger number of patients and a longer follow-up period is needed, this safe and thus far potent technique that catheter-based ablation cannot copy might extend indication of the Cox maze procedure for patients with tough atrial fibrillation.
Photoelectric observations of the long-period eclipsing binaries at Yonsei University Observatory
NASA Technical Reports Server (NTRS)
Nha, I. S.; Lee, Y. S.; Chun, Y. W.; Kim, H. I.; Kim, Y. S.
1985-01-01
A long term project (ten-years; 1982-92) for the photoelectric observation in the UBV passbands of selected eclipsing binaries with P 10 days has initiated at Yonsei University Observatory using 40-cm and 61-cm reflectors. The instrumentation used and the observation techniques and the reduction procedures applied to this investigation are described.
ERIC Educational Resources Information Center
Schandler, Steven L.; Dana, Edward R.
1983-01-01
Examined changes in tension behaviors and reductions in physiological tension associated with cognitive imagery and electromyographic biofeedback relaxation procedures in 45 college students. Results showed: imagery significantly reduced state anxiety. Self-rest was less effective; biofeedback greatly reduced physiological tension, but not state…
Towards "Inverse" Character Tables? A One-Step Method for Decomposing Reducible Representations
ERIC Educational Resources Information Center
Piquemal, J.-Y.; Losno, R.; Ancian, B.
2009-01-01
In the framework of group theory, a new procedure is described for a one-step automated reduction of reducible representations. The matrix inversion tool, provided by standard spreadsheet software, is applied to the central part of the character table that contains the characters of the irreducible representation. This method is not restricted to…
ROC and Loss Function Analysis in Sequential Testing
ERIC Educational Resources Information Center
Muijtjens, Arno M. M.; Van Luijk, Scheltus J.; Van Der Vleuten, Cees P. M.
2006-01-01
Sequential testing is applied to reduce costs in SP-based tests (OSCEs). Initially, all candidates take a screening test consisting of a part of the OSCE. Candidates who fail the screen sit the complete test, whereas those who pass the screen are qualified as a pass of the complete test. The procedure may result in a reduction of testing…
NASA Astrophysics Data System (ADS)
Jain, Shobhit; Tiso, Paolo; Haller, George
2018-06-01
We apply two recently formulated mathematical techniques, Slow-Fast Decomposition (SFD) and Spectral Submanifold (SSM) reduction, to a von Kármán beam with geometric nonlinearities and viscoelastic damping. SFD identifies a global slow manifold in the full system which attracts solutions at rates faster than typical rates within the manifold. An SSM, the smoothest nonlinear continuation of a linear modal subspace, is then used to further reduce the beam equations within the slow manifold. This two-stage, mathematically exact procedure results in a drastic reduction of the finite-element beam model to a one-degree-of freedom nonlinear oscillator. We also introduce the technique of spectral quotient analysis, which gives the number of modes relevant for reduction as output rather than input to the reduction process.
Integrand reduction for two-loop scattering amplitudes through multivariate polynomial division
NASA Astrophysics Data System (ADS)
Mastrolia, Pierpaolo; Mirabella, Edoardo; Ossola, Giovanni; Peraro, Tiziano
2013-04-01
We describe the application of a novel approach for the reduction of scattering amplitudes, based on multivariate polynomial division, which we have recently presented. This technique yields the complete integrand decomposition for arbitrary amplitudes, regardless of the number of loops. It allows for the determination of the residue at any multiparticle cut, whose knowledge is a mandatory prerequisite for applying the integrand-reduction procedure. By using the division modulo Gröbner basis, we can derive a simple integrand recurrence relation that generates the multiparticle pole decomposition for integrands of arbitrary multiloop amplitudes. We apply the new reduction algorithm to the two-loop planar and nonplanar diagrams contributing to the five-point scattering amplitudes in N=4 super Yang-Mills and N=8 supergravity in four dimensions, whose numerator functions contain up to rank-two terms in the integration momenta. We determine all polynomial residues parametrizing the cuts of the corresponding topologies and subtopologies. We obtain the integral basis for the decomposition of each diagram from the polynomial form of the residues. Our approach is well suited for a seminumerical implementation, and its general mathematical properties provide an effective algorithm for the generalization of the integrand-reduction method to all orders in perturbation theory.
Laboratory animal science: a resource to improve the quality of science.
Forni, M
2007-08-01
The contribution of animal experimentation to biomedical research is of undoubted value, nevertheless the real usefulness of animal models is still being hotly debated. Laboratory Animal Science is a multidisciplinary approach to humane animal experimentation that allows the choice of the correct animal model and the collection of unbiased data. Refinement, Reduction and Replacement, the "3Rs rule", are now widely accepted and have a major influence on animal experimentation procedures. Refinement, namely any decrease in the incidence or severity of inhumane procedures applied to animals, has been today extended to the entire lives of the experimental animals. Reduction of the number of animals used to obtain statistically significant data may be achieved by improving experimental design and statistical analysis of data. Replacement refers to the development of validated alternative methods. A Laboratory Animal Science training program in biomedical degrees can promote the 3Rs and improve the welfare of laboratory animals as well as the quality of science with ethical, scientific and economic advantages complying with the European requirement that "persons who carry out, take part in, or supervise procedures on animals, or take care of animals used in procedures, shall have had appropriate education and training".
Summary of Research 1997 Department of Systems Management.
1999-01-01
formulation and execution; impacts of budget allocation , reallocation, and reduction; imple- mentation of Defense Resource Management Systems; and the...flexible structure that can be applied to a wide range of resource allocation problems. PUBLICATIONS: Dolk, D., Murphy, M., and Thomas, G...policies, procedures, and rationale in deter- mining recruiting resource allocation decisions. The methodology relies on a review of the literature
Background of SAM atom-fraction profiles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ernst, Frank
Atom-fraction profiles acquired by SAM (scanning Auger microprobe) have important applications, e.g. in the context of alloy surface engineering by infusion of carbon or nitrogen through the alloy surface. However, such profiles often exhibit an artifact in form of a background with a level that anti-correlates with the local atom fraction. This article presents a theory explaining this phenomenon as a consequence of the way in which random noise in the spectrum propagates into the discretized differentiated spectrum that is used for quantification. The resulting model of “energy channel statistics” leads to a useful semi-quantitative background reduction procedure, which ismore » validated by applying it to simulated data. Subsequently, the procedure is applied to an example of experimental SAM data. The analysis leads to conclusions regarding optimum experimental acquisition conditions. The proposed method of background reduction is based on general principles and should be useful for a broad variety of applications. - Highlights: • Atom-fraction–depth profiles of carbon measured by scanning Auger microprobe • Strong background, varies with local carbon concentration. • Needs correction e.g. for quantitative comparison with simulations • Quantitative theory explains background. • Provides background removal strategy and practical advice for acquisition.« less
Residual stress alleviation of aircraft metal structures reinforced with filamentary composites
NASA Technical Reports Server (NTRS)
Kelly, J. B.; June, R. R.
1973-01-01
Methods to eliminate or reduce residual stresses in aircraft metal structures reinforced by filamentary composites are discussed. Residual stress level reductions were achieved by modifying the manufacturing procedures used during adhesive bonding. The residual stress alleviation techniques involved various forms of mechanical constraint which were applied to the components during bonding. Nine methods were evaluated, covering a wide range in complexity. All methods investigated during the program affected the residual stress level. In general, residual stresses were reduced by 70 percent or more from the stress level produced by conventional adhesive bonding procedures.
Stochastic DG Placement for Conservation Voltage Reduction Based on Multiple Replications Procedure
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Zhaoyu; Chen, Bokan; Wang, Jianhui
2015-06-01
Conservation voltage reduction (CVR) and distributed-generation (DG) integration are popular strategies implemented by utilities to improve energy efficiency. This paper investigates the interactions between CVR and DG placement to minimize load consumption in distribution networks, while keeping the lowest voltage level within the predefined range. The optimal placement of DG units is formulated as a stochastic optimization problem considering the uncertainty of DG outputs and load consumptions. A sample average approximation algorithm-based technique is developed to solve the formulated problem effectively. A multiple replications procedure is developed to test the stability of the solution and calculate the confidence interval ofmore » the gap between the candidate solution and optimal solution. The proposed method has been applied to the IEEE 37-bus distribution test system with different scenarios. The numerical results indicate that the implementations of CVR and DG, if combined, can achieve significant energy savings.« less
MARKOV: A methodology for the solution of infinite time horizon MARKOV decision processes
Williams, B.K.
1988-01-01
Algorithms are described for determining optimal policies for finite state, finite action, infinite discrete time horizon Markov decision processes. Both value-improvement and policy-improvement techniques are used in the algorithms. Computing procedures are also described. The algorithms are appropriate for processes that are either finite or infinite, deterministic or stochastic, discounted or undiscounted, in any meaningful combination of these features. Computing procedures are described in terms of initial data processing, bound improvements, process reduction, and testing and solution. Application of the methodology is illustrated with an example involving natural resource management. Management implications of certain hypothesized relationships between mallard survival and harvest rates are addressed by applying the optimality procedures to mallard population models.
Schmid, Patrick; Yao, Hui; Galdzicki, Michal; Berger, Bonnie; Wu, Erxi; Kohane, Isaac S.
2009-01-01
Background Although microarray technology has become the most common method for studying global gene expression, a plethora of technical factors across the experiment contribute to the variable of genome gene expression profiling using peripheral whole blood. A practical platform needs to be established in order to obtain reliable and reproducible data to meet clinical requirements for biomarker study. Methods and Findings We applied peripheral whole blood samples with globin reduction and performed genome-wide transcriptome analysis using Illumina BeadChips. Real-time PCR was subsequently used to evaluate the quality of array data and elucidate the mode in which hemoglobin interferes in gene expression profiling. We demonstrated that, when applied in the context of standard microarray processing procedures, globin reduction results in a consistent and significant increase in the quality of beadarray data. When compared to their pre-globin reduction counterparts, post-globin reduction samples show improved detection statistics, lowered variance and increased sensitivity. More importantly, gender gene separation is remarkably clearer in post-globin reduction samples than in pre-globin reduction samples. Our study suggests that the poor data obtained from pre-globin reduction samples is the result of the high concentration of hemoglobin derived from red blood cells either interfering with target mRNA binding or giving the pseudo binding background signal. Conclusion We therefore recommend the combination of performing globin mRNA reduction in peripheral whole blood samples and hybridizing on Illumina BeadChips as the practical approach for biomarker study. PMID:19381341
NASA Astrophysics Data System (ADS)
Soldner, Dominic; Brands, Benjamin; Zabihyan, Reza; Steinmann, Paul; Mergheim, Julia
2017-10-01
Computing the macroscopic material response of a continuum body commonly involves the formulation of a phenomenological constitutive model. However, the response is mainly influenced by the heterogeneous microstructure. Computational homogenisation can be used to determine the constitutive behaviour on the macro-scale by solving a boundary value problem at the micro-scale for every so-called macroscopic material point within a nested solution scheme. Hence, this procedure requires the repeated solution of similar microscopic boundary value problems. To reduce the computational cost, model order reduction techniques can be applied. An important aspect thereby is the robustness of the obtained reduced model. Within this study reduced-order modelling (ROM) for the geometrically nonlinear case using hyperelastic materials is applied for the boundary value problem on the micro-scale. This involves the Proper Orthogonal Decomposition (POD) for the primary unknown and hyper-reduction methods for the arising nonlinearity. Therein three methods for hyper-reduction, differing in how the nonlinearity is approximated and the subsequent projection, are compared in terms of accuracy and robustness. Introducing interpolation or Gappy-POD based approximations may not preserve the symmetry of the system tangent, rendering the widely used Galerkin projection sub-optimal. Hence, a different projection related to a Gauss-Newton scheme (Gauss-Newton with Approximated Tensors- GNAT) is favoured to obtain an optimal projection and a robust reduced model.
Willegaignon, José; Braga, Luis F E F; Sapienza, Marcelo T; Coura-Filho, George B; Cardona, Marissa A R; Alves, Carlos E R; Gutterres, Ricardo F; Buchpiguel, Carlos A
2016-05-01
This study aimed to establish a concise method for determining a diagnostic reference level (DRL) for adult and pediatric nuclear medicine patients on the basis of diagnostic procedures and administered radioisotope as a means of controlling medical exposure. A screening was carried out in all Brazilian Nuclear Medicine Service (NMS) establishments to support this study by collecting the average activities administered during adult diagnostic procedures and the rules applied to adjust these according to the patient's age and body mass. Percentile 75 was used in all the activities administered as a means of establishing DRL for adult patients, with additional correction factors for pediatric patients. Radiation doses from nuclear medicine procedures on the basis of average administered activity were calculated for all diagnostic exams. A total of 107 NMSs in Brazil agreed to participate in the project. From the 64 nuclear medicine procedures studied, bone, kidney, and parathyroid scans were found to be used in more than 85% of all the NMSs analyzed. There was a large disparity among the activities administered, when applying the same procedures, this reaching, in some cases, more than 20 times between the lowest and the highest. Diagnostic exams based on Ga, Tl, and I radioisotopes proved to be the major exams administering radiation doses to patients. On introducing the DRL concept into clinical routine, the minimum reduction in radiation doses received by patients was about 15%, the maximum was 95%, and the average was 50% compared with the previously reported administered activities. Variability in the available diagnostic procedures as well as in the amount of activities administered within the same procedure was appreciable not only in Brazil, but worldwide. Global efforts are needed to establish a concise DRL that can be applied in adult and pediatric nuclear medicine procedures as the application of DRL in clinical routine has been proven to be an important tool for controlling and reducing radiation doses received by patients in medical exposure.
Sensitivity Analysis for Probabilistic Neural Network Structure Reduction.
Kowalski, Piotr A; Kusy, Maciej
2018-05-01
In this paper, we propose the use of local sensitivity analysis (LSA) for the structure simplification of the probabilistic neural network (PNN). Three algorithms are introduced. The first algorithm applies LSA to the PNN input layer reduction by selecting significant features of input patterns. The second algorithm utilizes LSA to remove redundant pattern neurons of the network. The third algorithm combines the proposed two and constitutes the solution of how they can work together. PNN with a product kernel estimator is used, where each multiplicand computes a one-dimensional Cauchy function. Therefore, the smoothing parameter is separately calculated for each dimension by means of the plug-in method. The classification qualities of the reduced and full structure PNN are compared. Furthermore, we evaluate the performance of PNN, for which global sensitivity analysis (GSA) and the common reduction methods are applied, both in the input layer and the pattern layer. The models are tested on the classification problems of eight repository data sets. A 10-fold cross validation procedure is used to determine the prediction ability of the networks. Based on the obtained results, it is shown that the LSA can be used as an alternative PNN reduction approach.
Madi, Marwa; Kassem, Abeer
2018-04-01
Autogenous soft-tissue grafting is a commonly used procedure nowadays in dentistry. However, the prolonged healing time needed for the donor site leads to increase the patient's pain and discomfort. Statin has been observed to be beneficial in reducing bacterial burden, improving epithelization and wound healing. The aim of this study was to evaluate intra-oral topical application of simvastatin/chitosan gel (10 mg/mL) over the palatal donor site following free gingival graft (FGG) procedure. Subjects indicated for FGG procedure were divided into four groups. Group I: Simvastatin suspension (S), group II: simvastatin/chitosan gel (SC), group III: chitosan gel (C), group IV: petroleum gel (P). Treatment was applied three times/day for the following 7 days. Wound healing was evaluated at day 3, 7 and 14 post-surgery. A visual analogue scale (VAS) was used to measure the experienced discomfort at 1, 3, 5, 7 and 14 days. Statistical significant reduction in wound-healing scores was observed after 3 and 7 days for group II compared to other groups (p = .015). A significant reduction was also observed in VAS score for group II compared to other groups at day 1, 3, 5 and 7. Topical application of S/C gel could be used as a novel therapeutic modality that improved healing and reduced pain in the palatal donor site following FGG procedure.
Hernandez, Purnima; Ikkanda, Zachary
2011-03-01
There are a limited number of studies addressing behavior management techniques and procedural modifications that dentists can use to treat people with an autism spectrum disorder (ASD). The authors conducted a search of the dental and behavioral analytic literature to identify management techniques that address problem behaviors exhibited by children with ASDs in dental and other health-related environments. Applied behavior analysis (ABA) is a science in which procedures are based on the principles of behavior through systematic experimentation. Clinicians have used ABA procedures successfully to modify socially significant behaviors of people with ASD. Basic behavior management techniques currently used in dentistry may not encourage people with cognitive and behavioral disabilities, such as ASD, to tolerate simple in-office dental procedures consistently. Instead, dental care providers often are required to use advanced behavior management techniques to complete simple in-office procedures such as prophylaxis, sealant placement and obtaining radiographs. ABA procedures can be integrated in the dental environment to manage problem behaviors often exhibited by children with an ASD. The authors found no evidence-based procedural modifications that address the behavioral characteristics and problematic behaviors of children with an ASD in a dental environment. Further research in this area should be conducted. Knowledge and in-depth understanding of behavioral principles is essential when a dentist is concerned with modifying behaviors. Using ABA procedures can help dentists manage problem behaviors effectively and systematically when performing routine dental treatment. Being knowledgeable about each patient's behavioral characteristics and the parents' level of involvement is important in the successful integration of the procedures and reduction of in-office time.
Use of an elastic transarticular external fixator construct for immobilization of the elbow joint.
Vedrine, Bertrand
2017-04-01
Transarticular external skeletal fixation usually involves rigid bars that result in a stable but stiff joint. This study describes the technique and the outcome of an elastic transarticular external fixator (ETEF) applied to the elbow joint. Four cases of elbow luxation with collateral ligament injuries were managed with closed reduction and application of an ETEF to maintain the reduction. A triceps tendon avulsion was surgically managed before applying an ETEF. The clinical outcome was considered excellent in 2 cats, good in 2 dogs (1 elbow luxation and the avulsion of the triceps tendon), and poor in 1 dog presented for elbow luxation and a permanent neurological defect. The procedure was rapid, easy to perform, and inexpensive. All animals except the one with a neurological defect had an early return to weight bearing. This method maintains extension of the joint while permitting its motion thereby promoting rehabilitation.
Use of an elastic transarticular external fixator construct for immobilization of the elbow joint
Vedrine, Bertrand
2017-01-01
Transarticular external skeletal fixation usually involves rigid bars that result in a stable but stiff joint. This study describes the technique and the outcome of an elastic transarticular external fixator (ETEF) applied to the elbow joint. Four cases of elbow luxation with collateral ligament injuries were managed with closed reduction and application of an ETEF to maintain the reduction. A triceps tendon avulsion was surgically managed before applying an ETEF. The clinical outcome was considered excellent in 2 cats, good in 2 dogs (1 elbow luxation and the avulsion of the triceps tendon), and poor in 1 dog presented for elbow luxation and a permanent neurological defect. The procedure was rapid, easy to perform, and inexpensive. All animals except the one with a neurological defect had an early return to weight bearing. This method maintains extension of the joint while permitting its motion thereby promoting rehabilitation. PMID:28373726
NASA Astrophysics Data System (ADS)
Jenness, Tim; Currie, Malcolm J.; Tilanus, Remo P. J.; Cavanagh, Brad; Berry, David S.; Leech, Jamie; Rizzi, Luca
2015-10-01
With the advent of modern multidetector heterodyne instruments that can result in observations generating thousands of spectra per minute it is no longer feasible to reduce these data as individual spectra. We describe the automated data reduction procedure used to generate baselined data cubes from heterodyne data obtained at the James Clerk Maxwell Telescope (JCMT). The system can automatically detect baseline regions in spectra and automatically determine regridding parameters, all without input from a user. Additionally, it can detect and remove spectra suffering from transient interference effects or anomalous baselines. The pipeline is written as a set of recipes using the ORAC-DR pipeline environment with the algorithmic code using Starlink software packages and infrastructure. The algorithms presented here can be applied to other heterodyne array instruments and have been applied to data from historical JCMT heterodyne instrumentation.
NASA Astrophysics Data System (ADS)
Campoamor-Stursberg, R.
2018-03-01
A procedure for the construction of nonlinear realizations of Lie algebras in the context of Vessiot-Guldberg-Lie algebras of first-order systems of ordinary differential equations (ODEs) is proposed. The method is based on the reduction of invariants and projection of lowest-dimensional (irreducible) representations of Lie algebras. Applications to the description of parameterized first-order systems of ODEs related by contraction of Lie algebras are given. In particular, the kinematical Lie algebras in (2 + 1)- and (3 + 1)-dimensions are realized simultaneously as Vessiot-Guldberg-Lie algebras of parameterized nonlinear systems in R3 and R4, respectively.
Mancosu, Pietro; Nicolini, Giorgia; Goretti, Giulia; De Rose, Fiorenza; Franceschini, Davide; Ferrari, Chiara; Reggiori, Giacomo; Tomatis, Stefano; Scorsetti, Marta
2018-05-01
Lean Six Sigma Methodology (LSSM) was introduced in industry to provide near-perfect services to large processes, by reducing improbable occurrence. LSSM has been applied to redesign the 2D-2D breast repositioning process (Lean) by the retrospective analysis of the database (Six Sigma). Breast patients with daily 2D-2D matching before RT were considered. The five DMAIC (define, measure, analyze, improve, and control) LSSM steps were applied. The process was retrospectively measured over 30 months (7/2014-12/2016) by querying the RT Record&Verify database. Two Lean instruments (Poka-Yoke and Visual Management) were considered for advancing the process. The new procedure was checked over 6 months (1-6/2017). 14,931 consecutive shifts from 1342 patients were analyzed. Only 0.8% of patients presented median shifts >1 cm. The major observed discrepancy was the monthly percentage of fractions with almost zero shifts (AZS = 13.2% ± 6.1%). Ishikawa fishbone diagram helped in defining the main discrepancy con-causes. Procedure harmonization involving a multidisciplinary team to increase confidence in matching procedure was defined. AZS was reduced to 4.8% ± 0.6%. Furthermore, distribution symmetry improvement (Skewness moved from 1.4 to 1.1) and outlier reduction, verified by Kurtosis diminution, demonstrated a better "normalization" of the procedure after the LSSM application. LSSM was implemented in a RT department, allowing to redesign the breast repositioning matching procedure. Copyright © 2018 Elsevier B.V. All rights reserved.
A modified procedure for mixture-model clustering of regional geochemical data
Ellefsen, Karl J.; Smith, David B.; Horton, John D.
2014-01-01
A modified procedure is proposed for mixture-model clustering of regional-scale geochemical data. The key modification is the robust principal component transformation of the isometric log-ratio transforms of the element concentrations. This principal component transformation and the associated dimension reduction are applied before the data are clustered. The principal advantage of this modification is that it significantly improves the stability of the clustering. The principal disadvantage is that it requires subjective selection of the number of clusters and the number of principal components. To evaluate the efficacy of this modified procedure, it is applied to soil geochemical data that comprise 959 samples from the state of Colorado (USA) for which the concentrations of 44 elements are measured. The distributions of element concentrations that are derived from the mixture model and from the field samples are similar, indicating that the mixture model is a suitable representation of the transformed geochemical data. Each cluster and the associated distributions of the element concentrations are related to specific geologic and anthropogenic features. In this way, mixture model clustering facilitates interpretation of the regional geochemical data.
Camacho, Ana María; Veganzones, Mariano; Claver, Juan; Martín, Francisco; Sevilla, Lorenzo; Sebastián, Miguel Ángel
2016-09-01
Tribological conditions can change drastically during heavy loaded regimes as experienced in metal forming; this is especially critical when lubrication can only be applied at the early stage of the process because the homogeneous lubricant layer can break along the die-workpiece interface. In these cases, adopting a constant friction factor for the lubricant-surface pair may not be a valid assumption. This paper presents a procedure based on the use of dual friction factor maps to determine friction factors employed in heavy loaded regimes. A finite element (FE) simulation is used to obtain the friction factor map for the alloy UNS A96082. Experiments were conducted using four lubricants (aluminum anti-size, MoS₂ grease, silicone oil, and copper paste) to determine the actual friction curves. The experimental procedure is based on the application of lubricant only at the beginning of the first stage of ring compression, and not at intermediate stages as is usual in typical ring compression tests (RCTs). The results show that for small reductions ( r h < 20%), the conventional RCT can be applied because the tribological conditions remain similar. For large reductions ( r h > 20%), it is recommended to obtain an average value of the friction factor for every lubricant-surface pair in the range of deformation considered.
Camacho, Ana María; Veganzones, Mariano; Claver, Juan; Martín, Francisco; Sevilla, Lorenzo; Sebastián, Miguel Ángel
2016-01-01
Tribological conditions can change drastically during heavy loaded regimes as experienced in metal forming; this is especially critical when lubrication can only be applied at the early stage of the process because the homogeneous lubricant layer can break along the die-workpiece interface. In these cases, adopting a constant friction factor for the lubricant-surface pair may not be a valid assumption. This paper presents a procedure based on the use of dual friction factor maps to determine friction factors employed in heavy loaded regimes. A finite element (FE) simulation is used to obtain the friction factor map for the alloy UNS A96082. Experiments were conducted using four lubricants (aluminum anti-size, MoS2 grease, silicone oil, and copper paste) to determine the actual friction curves. The experimental procedure is based on the application of lubricant only at the beginning of the first stage of ring compression, and not at intermediate stages as is usual in typical ring compression tests (RCTs). The results show that for small reductions (rh < 20%), the conventional RCT can be applied because the tribological conditions remain similar. For large reductions (rh > 20%), it is recommended to obtain an average value of the friction factor for every lubricant-surface pair in the range of deformation considered. PMID:28773868
[Tongue base reduction with radiofrequency energy in sleep apnea].
Stuck, B A; Maurer, J T; Hörmann, K
2001-07-01
Tongue base reduction with temperature-controlled radiofrequency for the treatment of obstructive sleep apnea syndrome is a minimally invasive technique. Repeated application leads to a progressive shrinking of the tissue. In our study, we summarize the experiences gained from 100 tongue base reductions and compare them with the pilot study that was recently published. An intensified treatment scheme was used with higher amounts of energy applied per treatment session. Visual analogue scales were used for the assessment of postoperative pain and functional parameters. Regular follow-up visits were scheduled to evaluate postoperative complications. Postoperative pain was mostly mild or moderate. Paraoperative complications were not observed. The overall rate for postoperative complications was 8%, with 2% mild and 5% moderate complications. One severe complication--a tongue base abscedation--was observed. Using para- and postoperative antibiotic prophylaxis reduced the rate of complications. Functional parameters such as taste or swallowing were not affected. Our results underline the safety of the procedure and demonstrate the minimal para- and postoperative morbidity. The increased amount of energy applied per session has not led to an increase in postoperative morbidity.
Escrig-Tena, I; Alvarez Rodríguez, L; Esteve-Romero, J; García-Alvarez-Coque, M C
1998-09-01
Nitrobenzenes, such as the antibiotic chloramphenicol, the vasodilator nicardipine, and the herbicides dinitramin, dinobuton, fenitrothion, methylparathion, oxyfluorfen, parathion, pendimethalin, quintozene, and trifluralin, were determined by using a spectrophotometric method in the visible region (540 nm). The method was based on the reduction of the nitrobenzenes to arylamines with tin(II) chloride, diazotisation of the arylamines and coupling of the diazonium ions with the Bratton-Marshall reagent. The two latter reactions were performed in a micellar medium of sodium dodecyl sulphate. The linear calibration range was 2x10(-6) to 7x10(-5) M (r>0.999), with limits of detection in the 10(-7) M level, which is 2-6 fold lower with respect to the corresponding spectrophotometric procedure in non-micellar medium. The procedure was applied to the analysis of the compounds in commercial preparations (pharmaceuticals and herbicide formulations) and in water samples, with good recoveries.
Experimental scrambling and noise reduction applied to the optical encryption of QR codes.
Barrera, John Fredy; Vélez, Alejandro; Torroba, Roberto
2014-08-25
In this contribution, we implement two techniques to reinforce optical encryption, which we restrict in particular to the QR codes, but could be applied in a general encoding situation. To our knowledge, we present the first experimental-positional optical scrambling merged with an optical encryption procedure. The inclusion of an experimental scrambling technique in an optical encryption protocol, in particular dealing with a QR code "container", adds more protection to the encoding proposal. Additionally, a nonlinear normalization technique is applied to reduce the noise over the recovered images besides increasing the security against attacks. The opto-digital techniques employ an interferometric arrangement and a joint transform correlator encrypting architecture. The experimental results demonstrate the capability of the methods to accomplish the task.
Ingargiola, Michael J; Motakef, Saba; Chung, Michael T; Vasconez, Henry C; Sasaki, Gordon H
2015-06-01
Cryolipolysis is a nonsurgical technique for localized fat reduction. With the increased risk of complications from more invasive methods such as liposuction, cryolipolysis presents a promising method for nonsurgical body contouring. This study presents a systematic review of the available clinical data, with an emphasis on the efficacy, methods, safety, and complications of cryolipolysis. To identify clinical studies that assessed outcomes of cryolipolysis, a systematic review of the MEDLINE and Cochrane databases was performed with the search algorithm cryolipolysis OR cool sculpting OR fat freezing OR lipocryolysis. The primary literature search returned 319 articles. After inclusion criteria were applied and additional articles were idenfied via manual review of article references, 19 studies were selected for review. Average reduction in caliper measurement ranged from 14.67 percent to 28.5 percent. Average reduction by ultrasound ranged from 10.3 percent to 25.5 percent. No significant impact on lipid levels or liver function tests after cryolipolysis treatments was noted in any study. Only mild, short-term side effects, such as erythema, swelling, and pain, were noted. Paradoxical adipose hyperplasia was described in one patient. Cryolipolysis is a promising procedure for nonsurgical fat reduction and body contouring and presents a compelling alternative to liposuction and other, more invasive methods. This procedure appears to be safe in the short term, with a limited side effect profile, and results in significant fat reduction when used for localized adiposities. It remains unclear whether posttreatment manual massage and multiple treatments in the same anatomic area enhance the efficacy of cryolipolysis.
ERIC Educational Resources Information Center
Hoko, J. Aaron; LeBlanc, Judith M.
1988-01-01
Because disabled learners may profit from procedures using gradual stimulus change, this study utilized a microcomputer to investigate the effectiveness of stimulus equalization, an error reduction procedure involving an abrupt but temporary reduction of dimensional complexity. The procedure was found to be generally effective and implications for…
The use of phosphatidylcholine for correction of localized fat deposits.
Rittes, Patrícia Guedes
2003-01-01
Subjects with localized fat deposits commonly receive suction lipectomy as a cosmetic procedure. A new office procedure for correction of those superficial fat deposits was applied in 50 patients by injection of phosphatidylcholine. The method itself consists of using a 3OG1/2 insulin needle to inject about 5 ml (250 mg/5 ml) of phosphatidylcholine into the fat, distributing it evenly in an 80 cm2 area. Pre- and posttreatment photographs were taken for technical planning and analysis of the results over the long term. A clear improvement occurred in all, with a marked reduction of the fat deposits without recurrence over a 2-year follow-up period and no weight gain. The injection of phosphatidylcholine into the fat deposits is a simple office procedure that can sometimes postpone or even replace surgery and liposuction.
Capillary Electrophoresis of Mono- and Oligosaccharides.
Toppazzini, Mila; Coslovi, Anna; Rossi, Marco; Flamigni, Anna; Baiutti, Edi; Campa, Cristiana
2016-01-01
This chapter reports an overview of the recent advances in the analysis of mono- and oligosaccharides by capillary electrophoresis (CE); furthermore, relevant reviews and research articles recently published in the field are tabulated. Additionally, pretreatments and procedures applied to uncharged and acidic carbohydrates (i.e., monosaccharides and lower oligosaccharides carrying carboxylate, sulfate, or phosphate groups) are described.Representative examples of such procedures are reported in detail, upon describing robust methodologies for the study of (1) neutral oligosaccharides derivatized by reductive amination and by formation of glycosylamines; (2) sialic acid derivatized with 2-aminoacridone, released from human serum immunoglobulin G; (3) anomeric couples of neutral glycosides separated using borate-based buffers; (4) unsaturated, underivatized oligosaccharides from lyase-treated alginate.
Chen, Szi-Wen; Chen, Yuan-Ho
2015-01-01
In this paper, a discrete wavelet transform (DWT) based de-noising with its applications into the noise reduction for medical signal preprocessing is introduced. This work focuses on the hardware realization of a real-time wavelet de-noising procedure. The proposed de-noising circuit mainly consists of three modules: a DWT, a thresholding, and an inverse DWT (IDWT) modular circuits. We also proposed a novel adaptive thresholding scheme and incorporated it into our wavelet de-noising procedure. Performance was then evaluated on both the architectural designs of the software and. In addition, the de-noising circuit was also implemented by downloading the Verilog codes to a field programmable gate array (FPGA) based platform so that its ability in noise reduction may be further validated in actual practice. Simulation experiment results produced by applying a set of simulated noise-contaminated electrocardiogram (ECG) signals into the de-noising circuit showed that the circuit could not only desirably meet the requirement of real-time processing, but also achieve satisfactory performance for noise reduction, while the sharp features of the ECG signals can be well preserved. The proposed de-noising circuit was further synthesized using the Synopsys Design Compiler with an Artisan Taiwan Semiconductor Manufacturing Company (TSMC, Hsinchu, Taiwan) 40 nm standard cell library. The integrated circuit (IC) synthesis simulation results showed that the proposed design can achieve a clock frequency of 200 MHz and the power consumption was only 17.4 mW, when operated at 200 MHz. PMID:26501290
Chen, Szi-Wen; Chen, Yuan-Ho
2015-10-16
In this paper, a discrete wavelet transform (DWT) based de-noising with its applications into the noise reduction for medical signal preprocessing is introduced. This work focuses on the hardware realization of a real-time wavelet de-noising procedure. The proposed de-noising circuit mainly consists of three modules: a DWT, a thresholding, and an inverse DWT (IDWT) modular circuits. We also proposed a novel adaptive thresholding scheme and incorporated it into our wavelet de-noising procedure. Performance was then evaluated on both the architectural designs of the software and. In addition, the de-noising circuit was also implemented by downloading the Verilog codes to a field programmable gate array (FPGA) based platform so that its ability in noise reduction may be further validated in actual practice. Simulation experiment results produced by applying a set of simulated noise-contaminated electrocardiogram (ECG) signals into the de-noising circuit showed that the circuit could not only desirably meet the requirement of real-time processing, but also achieve satisfactory performance for noise reduction, while the sharp features of the ECG signals can be well preserved. The proposed de-noising circuit was further synthesized using the Synopsys Design Compiler with an Artisan Taiwan Semiconductor Manufacturing Company (TSMC, Hsinchu, Taiwan) 40 nm standard cell library. The integrated circuit (IC) synthesis simulation results showed that the proposed design can achieve a clock frequency of 200 MHz and the power consumption was only 17.4 mW, when operated at 200 MHz.
General aviation aircraft interior noise problem: Some suggested solutions
NASA Technical Reports Server (NTRS)
Roskam, J.; Navaneethan, R.
1984-01-01
Laboratory investigation of sound transmission through panels and the use of modern data analysis techniques applied to actual aircraft is used to determine methods to reduce general aviation interior noise. The experimental noise reduction characteristics of stiffened flat and curved panels with damping treatment are discussed. The experimental results of double-wall panels used in the general aviation industry are given. The effects of skin panel material, fiberglass insulation and trim panel material on the noise reduction characteristics of double-wall panels are investigated. With few modifications, the classical sound transmission theory can be used to design the interior noise control treatment of aircraft. Acoustic intensity and analysis procedures are included.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gao Yajun
A previously established Hauser-Ernst-type extended double-complex linear system is slightly modified and used to develop an inverse scattering method for the stationary axisymmetric general symplectic gravity model. The reduction procedures in this inverse scattering method are found to be fairly simple, which makes the inverse scattering method applied fine and effective. As an application, a concrete family of soliton double solutions for the considered theory is obtained.
Loarie, Thomas M; Applegate, David; Kuenne, Christopher B; Choi, Lawrence J; Horowitz, Diane P
2003-01-01
Market segmentation analysis identifies discrete segments of the population whose beliefs are consistent with exhibited behaviors such as purchase choice. This study applies market segmentation analysis to low myopes (-1 to -3 D with less than 1 D cylinder) in their consideration and choice of a refractive surgery procedure to discover opportunities within the market. A quantitative survey based on focus group research was sent to a demographically balanced sample of myopes using contact lenses and/or glasses. A variable reduction process followed by a clustering analysis was used to discover discrete belief-based segments. The resulting segments were validated both analytically and through in-market testing. Discontented individuals who wear contact lenses are the primary target for vision correction surgery. However, 81% of the target group is apprehensive about laser in situ keratomileusis (LASIK). They are nervous about the procedure and strongly desire reversibility and exchangeability. There exists a large untapped opportunity for vision correction surgery within the low myope population. Market segmentation analysis helped determine how to best meet this opportunity through repositioning existing procedures or developing new vision correction technology, and could also be applied to identify opportunities in other vision correction populations.
Bioassays with terrestrial and aquatic species as monitoring tools of hydrocarbon degradation.
Bori, Jaume; Vallès, Bettina; Ortega, Lina; Riva, Maria Carme
2016-09-01
In this study chemical analyses and ecotoxicity tests were applied for the assessment of a heavily hydrocarbon-contaminated soil prior and after the application of a remediation procedure that consisted in the stimulation of soil autochthonous populations of hydrocarbon degraders in static-ventilated biopiles. Terrestrial bioassays were applied in mixtures of test soils and artificial control soil and studied the survival and reproduction of Eisenia fetida and the avoidance response of E. fetida and Folsomia candida. Effects on aquatic organisms were studied by means of acute tests with Vibrio fischeri, Raphidocelis subcapitata, and Daphnia magna performed on aqueous elutriates from test soils. The bioremediation procedure led to a significant reduction in the concentration of hydrocarbons (from 34264 to 3074 mg kg(-1), i.e., 91 % decrease) and toxicity although bioassays were not able to report a percentage decrease of toxicity as high as the percentage reduction. Sublethal tests proved the most sensitive terrestrial bioassays and avoidance tests with earthworms and springtails showed potential as monitoring tools of hydrocarbon remediation due to their high sensitivity and short duration. The concentrations of hydrocarbons in water extracts from test soils were 130 and 100 μg L(-1) before and after remediation, respectively. Similarly to terrestrial tests, most aquatic bioassays detected a significant reduction in toxicity, which was almost negligible at the end of the treatment. D. magna survival was the most affected by soil elutriates although toxicity to the crustacean was associated to the salinity of the samples rather than to the concentration of hydrocarbons. Ecotoxicity tests with aqueous soil elutriates proved less relevant in the assessment of hydrocarbon-contaminated soils due to the low hydrosolubility of hydrocarbons and the influence of the physicochemical parameters of the aquatic medium.
Winayak, Amar; Gossat, Alyza; Cooper, Jenny; Ritchie, Peter; Lim, Wei; Klim, Sharon; Kelly, Anne-Maree
2018-02-01
Research suggests that the presence of instability markers in patients with displaced distal radial fractures is associated with poorer outcome. Our aims were to determine whether the presence of previously defined instability markers could predict the likelihood of successful ED reduction and requirement for a secondary procedure after ED reduction. Retrospective cohort study performed by medical record review. Adult ED patients coded as having an isolated wrist fracture and having fracture reduction in ED were eligible for inclusion. Data collected included demographics, history of osteoporosis, mechanism of injury, radiological features on X-rays and performance of a secondary procedure. Outcomes of interest were the rate of successful fracture reduction in ED (against defined radiological criteria), the rate of secondary procedures and the association between the number of defined instability risk factors and successful reduction and performance of a secondary surgical procedure. Analysis was by χ 2 test, receiver operating characteristic curve, logistic regression analyses. Three hundred and nineteen patients were studied; median age 62 years, 77% female. Sixty-five per cent of patients had satisfactory fracture reduction in ED (95% CI 59%-70%). Eighty-six patients underwent a secondary procedure to reduce/stabilise their fracture (28%, 95% CI 23%-33%). Younger age, lack of satisfactory ED reduction and increased number of instability factors were independently predictive of the performance of a secondary procedure. Instability risk factors are common in patients with wrist fractures requiring reduction in ED. The number of instability factors is not a strong predictor of the performance of secondary procedures. © 2017 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.
Reduction mammoplasty operative techniques for improved outcomes in the treatment of gigantomastia.
Degeorge, Brent R; Colen, David L; Mericli, Alexander F; Drake, David B
2013-01-01
Gigantomastia, or excessive breast hypertrophy, which is broadly defined as macromastia requiring a surgical reduction of more than 1500 g of breast tissue per breast, poses a unique problem to the reconstructive surgeon. Various procedures have been described for reduction mammoplasty with specific skin incisions, patterns of breast parenchymal resection, and blood supply to the nipple-areolar complex; however, not all of these techniques can be directly applied in the setting of gigantomastia. We outline a simplified method for preoperative evaluation and operative technique, which has been optimized for the management of gigantomastia. A retrospective chart review of patients who have undergone reduction mammoplasty from 2006 to 2011 by a single surgeon at the University of Virginia was performed. Patients were subdivided based on weight of breast tissue resection into 2 groups: macromastia (<1500 g resection per breast) and gigantomastia (>1500 g resection per breast). Endpoints including patient demographics, operative techniques, and complication rates were recorded. The mean resection weights in the macromastia and gigantomastia groups, respectively, were 681 g ± 283 g and 2554 g ± 421 g. There were no differences in major complications between the 2 groups. The rate of free nipple graft utilization was not significantly different between the 2 groups. Our surgical approach to gigantomastia has advantages when applied to extremely large-volume breast reduction and provides both esthetic and reproducible results. The preoperative assessment and operative techniques described herein have been adapted to the management of gigantomastia to reduce the rates of surgical complications.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-07
... LEGAL SERVICES CORPORATION 45 CFR Parts 1606, 1618, and 1623 Termination, Limited Reductions in...- cost procedures (45 CFR part 1630). LSC has also adopted grant termination procedures (45 CFR part 1606... reduce a recipient's funding by less than five percent without using the 1606 termination procedures...
Derivation of an analytic expression for the error associated with the noise reduction rating
NASA Astrophysics Data System (ADS)
Murphy, William J.
2005-04-01
Hearing protection devices are assessed using the Real Ear Attenuation at Threshold (REAT) measurement procedure for the purpose of estimating the amount of noise reduction provided when worn by a subject. The rating number provided on the protector label is a function of the mean and standard deviation of the REAT results achieved by the test subjects. If a group of subjects have a large variance, then it follows that the certainty of the rating should be correspondingly lower. No estimate of the error of a protector's rating is given by existing standards or regulations. Propagation of errors was applied to the Noise Reduction Rating to develop an analytic expression for the hearing protector rating error term. Comparison of the analytic expression for the error to the standard deviation estimated from Monte Carlo simulation of subject attenuations yielded a linear relationship across several protector types and assumptions for the variance of the attenuations.
Facile chemical routes to mesoporous silver substrates for SERS analysis
Tastekova, Elina A; Polyakov, Alexander Yu; Goldt, Anastasia E; Sidorov, Alexander V; Oshmyanskaya, Alexandra A; Sukhorukova, Irina V; Shtansky, Dmitry V; Grünert, Wolgang
2018-01-01
Mesoporous silver nanoparticles were easily synthesized through the bulk reduction of crystalline silver(I) oxide and used for the preparation of highly porous surface-enhanced Raman scattering (SERS)-active substrates. An analogous procedure was successfully performed for the production of mesoporous silver films by chemical reduction of oxidized silver films. The sponge-like silver blocks with high surface area and the in-situ-prepared mesoporous silver films are efficient as both analyte adsorbents and Raman signal enhancement mediators. The efficiency of silver reduction was characterized by X-ray diffraction and X-ray photoelectron spectroscopy. The developed substrates were applied for SERS detection of rhodamine 6G (enhancement factor of about 1–5 × 105) and an anti-ischemic mildronate drug (meldonium; enhancement factor of ≈102) that is known for its ability to increase the endurance performance of athletes. PMID:29600149
Air pollution mitigation measures for airports and associated activity. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1994-05-01
This report is a reference guide to emission mitigation techniques that can be applied to aircraft and their operations, the ground support equipment that service aircraft at airports, and other airport on-road and off-road emission sources such as maintenance, passenger, and employee vehicles. Each measure is described along with guidelines for its use and constraints that may limit its effectiveness. The information in the report can be used to quantify emission reductions that result from operational, procedural, or technological changes to these sources. Projects and plans to reduce air pollution at U.S. and European airports are described. A detailed descriptionmore » of procedures used to calculate aircraft emissions is provided in an appendix.« less
Angular-contact ball-bearing internal load estimation algorithm using runtime adaptive relaxation
NASA Astrophysics Data System (ADS)
Medina, H.; Mutu, R.
2017-07-01
An algorithm to estimate internal loads for single-row angular contact ball bearings due to externally applied thrust loads and high-operating speeds is presented. A new runtime adaptive relaxation procedure and blending function is proposed which ensures algorithm stability whilst also reducing the number of iterations needed to reach convergence, leading to an average reduction in computation time in excess of approximately 80%. The model is validated based on a 218 angular contact bearing and shows excellent agreement compared to published results.
Reduction of a linear complex model for respiratory system during Airflow Interruption.
Jablonski, Ireneusz; Mroczka, Janusz
2010-01-01
The paper presents methodology of a complex model reduction to its simpler version - an identifiable inverse model. Its main tool is a numerical procedure of sensitivity analysis (structural and parametric) applied to the forward linear equivalent designed for the conditions of interrupter experiment. Final result - the reduced analog for the interrupter technique is especially worth of notice as it fills a major gap in occlusional measurements, which typically use simple, one- or two-element physical representations. Proposed electrical reduced circuit, being structural combination of resistive, inertial and elastic properties, can be perceived as a candidate for reliable reconstruction and quantification (in the time and frequency domain) of dynamical behavior of the respiratory system in response to a quasi-step excitation by valve closure.
Thibault, Bernard; Andrade, Jason G; Dubuc, Marc; Talajic, Mario; Guerra, Peter G; Dyrda, Katia; Macle, Laurent; Rivard, Léna; Roy, Denis; Mondésert, Blandine; Khairy, Paul
2015-01-01
Cardiac resynchronization therapy (CRT) implant procedures are often complex and prolonged, resulting in significant ionizing radiation (IR) exposure to the patient and operator. We report our early experience working with a novel sensor-based electromagnetic tracking system (MediGuide™, MDG, St. Jude Medical Inc., St. Paul, MN, USA), in terms of procedural IR exposure reduction. Information regarding patient demographics, procedural details, procedural duration, and IR exposure were prospectively collected on 130 consecutive CRT procedures performed between January 2013 and January 2014. Sixty procedures were performed with MDG guidance, and 70 were performed without MDG guidance. Despite a nonsignificant trend toward shorter procedure duration with the use of MDG (120 minutes vs 138 minutes with non-MDG, P = 0.088), a 66% reduction in total IR exposure (median 769 μGray · m(2) vs 2,608 μGray · m(2), P < 0.001) was found. This reduction was primarily driven by a >90% reduction in IR dose required to cannulate the coronary sinus (median 80 μGray · m(2) vs 922 μGray · m(2), P < 0.001), and to a lesser extent from a reduction in IR dose required for LV lead placement (median 330 μGray·m(2) vs 737 μGray · m(2), P = 0.059). In addition, a significant learning curve effect was observed with a significantly shorter procedural duration for the last 15 cases compared to the first 15 cases (median 98 minutes vs 175 minutes, P < 0.001). The nonfluoroscopic MDG positioning system is associated with a dramatic reduction in exposure to IR during CRT implant procedures, with a 90% decrease in the IR dose required to cannulate the coronary sinus. A steep learning curve was quantified. ©2014 Wiley Periodicals, Inc.
Optimal parameters to avoid thermal necrosis during bone drilling: A finite element analysis.
Mediouni, Mohamed; Schlatterer, Daniel R; Khoury, Amal; Von Bergen, Tobias; Shetty, Sunil H; Arora, Manit; Dhond, Amit; Vaughan, Neil; Volosnikov, Alexander
2017-11-01
The drilling bone may potentially cause excessive frictional heat, which can lead to local bone necrosis. This heat generation and local necrosis has been suggested to contribute to the resorption of bone around the placed screws, ending in loss of screw purchase in the bone and inadvertent loosening and/or the bone-implant construct. In vivo studies on this subject have inherent obstacles not the least of which is controlling the variables and real time bone temperature data acquisition. Theoretical models can be generated using computer software and the inclusion of known constants for the mechanical properties of metal and bone. These known Data points for the variables (drill bit and bone) enables finite element analysis of various bone drilling scenarios. An elastic-plastic three-dimensional (3D) acetabular bone mode was developed and finite element model analysis (FEA) was applied to various simulated drilling procedures. The FEA results clearly indicate that the depth of drilling and the drill speed both have a significant effect on the temperature during drilling procedures. The reduction of the feeding speed leads to a reduction in bone temperature. Our data suggests that reducing the feeding speed regardless of RPMs and pressure applied could be a simple useful and effective way to reduce drilling temperatures. This study is the first step in helping any surgeon who drills bone and places screws to better understand the ideal pressure to apply and drill speed to employ and advance rate to avoid osteonecrosis. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2386-2391, 2017. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Costa, Annamaria; Colosio, Claudio; Gusmara, Claudia; Sala, Vittorio; Guarino, Marcella
2014-01-01
In the last decades, large-scale swine production has led to intensive rearing systems in which air quality can be easily degraded by aerial contaminants that can pose a health risk to the pigs and farm workers. This study evaluated the effects of fogging disinfectant procedure on productive performance, ammonia and dust concentration, aerobic bacteria and fungal spores spreading in the farrowing-weaning room. This trial was conducted in 2 identical farrowing-weaning rooms of a piggery. In both rooms, 30 pregnant sows were lodged in individual cages. At 75 days of age, the piglets were moved to the fattening room. In the treated room, with the birth of the first suckling-pig, the fogging disinfection with diluted Virkon S was applied once a day in the experimental room per 15 minutes at 11:00. The fogging disinfectant treatment was switched between rooms at the end of the first trial period. Temperature, relative humidity, dust (TSP-RF fractions and number of particles), ammonia concentration and aerial contaminants (enterococci, Micrococcaeae and fungal spores) were monitored in both rooms. Ammonia concentration reduction induced by fogging disinfection was estimated 18%, total suspended particles and the respirable fraction were significantly lower in the experimental room. Fungal spores resulted in a significant reduction by the fogging procedure, together with dust respirable fraction and fine particulate matter abatement. The fogging disinfection procedure improved air quality in the piggery, thereby enhancing workers and animals health.
Brycht, Mariola; Skrzypek, Sławomira; Guzsvány, Valéria; Berenji, Janoš
2013-12-15
A new square-wave adsorptive stripping voltammetric (SWAdSV) method was developed for the determination of the neonicotinoid insecticide clothianidin (Clo), based on its reduction at a renewable silver amalgam film electrode (Hg(Ag)FE). The key point of the procedure is the pretreatment of the Hg(Ag)FE by applying the appropriate conditioning potential (-1.70 V vs. Ag/AgCl reference electrode). Under the optimized voltammetric conditions, such pretreatment resulted in the peak for the Clo reduction in Britton-Robinson buffer pH 9.0 at about -0.60 V, which was used for the analytical purpose. The developed SWAdSV procedure made it possible to determine Clo in the concentration range of 6.0×10(-7)-7.0×10(-6) mol L(-1) (LOD=1.8×10(-7) mol L(-1), LOQ=6.0×10(-7) mol L(-1)) and 7.0×10(-6)-4.0×10(-5) mol L(-1) (LOD=1.3×10(-6) mol L(-1), LOQ=4.2×10(-6) mol L(-1)). The repeatability, precision, and the recovery of the method were determined. The effect of common interfering pesticides was also investigated. Standard addition method was successfully applied and validated for the determination of Clo in spiked Warta River water, corn seeds samples, and in corn seeds samples treated with the commercial formulation PONCHO 600 FS. © 2013 Elsevier B.V. All rights reserved.
Hussein, Khaled; Türk, Michael; Wahl, Martin A
2008-03-03
To improve dissolution properties of drugs, a supercritical fluid (SCF) technique was used to load these drugs into a solid carrier. In this study, granules based on beta-cyclodextrin (betaCD) were applied as a carrier for poor water-soluble drug and loaded with a model drug (ibuprofen) using two different procedures: controlled particle deposition (CPD), SCF process and solution immersion (SI) as a conventional method for comparison. Using the CPD technique, 17.42+/-2.06wt.% (n=3) ibuprofen was loaded into betaCD-granules, in contrast to only 3.8+/-0.15wt.% (n=3) in the SI-product. The drug loading was confirmed as well by reduction of the BET surface area for the CPD-product (1.134+/-0.07m(2)/g) compared to the unloaded-granules (1.533+/-0.031m(2)/g). Such a reduction was not seen in the SI-product (1.407+/-0.048m(2)/g). The appearance of an endothermic melting peak at 77 degrees C and X-ray patterns representing ibuprofen in drug-loaded granules can be attributed to the amount of ibuprofen loaded in its crystalline form. A significant increase in drug dissolution was achieved by either drug-loading procedures compared to the unprocessed ibuprofen. In this study, the CPD technique, a supercritical fluid process avoiding the use of toxic or organic solvents was successfully applied to load drug into solid carriers, thereby improving the water-solubility of the drug.
Talasila, Sreya; Evers-Meltzer, Rachel; Xu, Shuai
2018-06-05
Minimally invasive fat reduction procedures are rapidly growing in popularity. Evaluate online patient reviews to inform practice management. Data from RealSelf.com, a popular online aesthetics platform, were reviewed for all minimally invasive fat reduction procedures. Reviews were also aggregated based on the primary method of action (e.g., laser, radiofrequency, ultrasound, etc.) and compared with liposuction. A chi-square test was used to assess for differences with the Marascuilo procedure for pairwise comparisons. A total of 13 minimally invasive fat reduction procedures were identified encompassing 11,871 total reviews. Liposuction had 4,645 total reviews and a 66% patient satisfaction rate. Minimally invasive fat reduction procedures had 7,170 aggregate reviews and a global patient satisfaction of 58%. Liposuction had statistically significantly higher patient satisfaction than cryolipolysis (55% satisfied, n = 2,707 reviews), laser therapies (61% satisfied, n = 3,565 reviews), and injectables (49% satisfied, n = 319 reviews) (p < .05). Injectables and cryolipolysis had statistically significantly lower patient satisfaction than radiofrequency therapies (63% satisfied, n = 314 reviews) and laser therapies. Ultrasound therapies had 275 reviews and a 73% patient satisfaction rate. A large number of patient reviews suggest that minimally invasive fat reduction procedures have high patient satisfaction, although liposuction still had the highest total patient satisfaction score. However, there are significant pitfalls in interpreting patient reviews, as they do not provide important data such as a patient's medical history or physician experience and skill.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Merritt, Z; Dave, J; Eschelman, D
Purpose: To investigate the effects of image receptor technology and dose reduction software on radiation dose estimates for most frequently performed fluoroscopically-guided interventional (FGI) procedures at a tertiary health care center. Methods: IRB approval was obtained for retrospective analysis of FGI procedures performed in the interventional radiology suites between January-2011 and December-2015. This included procedures performed using image-intensifier (II) based systems which were subsequently replaced, flat-panel-detector (FPD) based systems which were later upgraded with ClarityIQ dose reduction software (Philips Healthcare) and relatively new FPD system already equipped with ClarityIQ. Post procedure, technologists entered system-reported cumulative air kerma (CAK) and kerma-areamore » product (KAP; only KAP for II based systems) in RIS; these values were analyzed. Data pre-processing included correcting typographical errors and cross-verifying CAK and KAP. The most frequent high and low dose FGI procedures were identified and corresponding CAK and KAP values were compared. Results: Out of 27,251 procedures within this time period, most frequent high and low dose procedures were chemo/immuno-embolization (n=1967) and abscess drainage (n=1821). Mean KAP for embolization and abscess drainage procedures were 260,657, 310,304 and 94,908 mGycm{sup 2}, and 14,497, 15,040 and 6307 mGycm{sup 2} using II-, FPD- and FPD with ClarityIQ- based systems, respectively. Statistically significant differences were observed in KAP values for embolization procedures with respect to different systems but for abscess drainage procedures significant differences were only noted between systems with FPD and FPD with ClarityIQ (p<0.05). Mean CAK reduced significantly from 823 to 308 mGy and from 43 to 21 mGy for embolization and abscess drainage procedures, respectively, in transitioning to FPD systems with ClarityIQ (p<0.05). Conclusion: While transitioning from II- to FPD- based systems was not associated with dose reduction for the most frequently performed FGI procedures, substantial dose reduction was noted with relatively newer systems and dose reduction software.« less
Willis, Franziska; Kuniss, Sarah; Kleindienst, Nikolaus; Naoum, Janina; Reitz, Sarah; Boll, Sabrina; Bohus, Martin; Treede, Rolf-Detlef; Baumgärtner, Ulf; Schmahl, Christian
2017-03-01
Approximately 60% to 90% of patients with borderline personality disorder (BPD) show nonsuicidal self-injurious behavior (NSSI) with cutting being the most frequently applied method. One of NSSI's functions is to reduce aversive tension. Previous studies have found a tension-reducing effect of painful tissue injury by an incision. It is still unclear whether this effect is based on the effect of tissue injury or the effect of pain experience, or both. The aim of this study was to determine whether tissue injury leads to a stronger stress reduction than a sole pain stimulus in patients with BPD. After stress induction, 57 BPD patients and 60 healthy controls (HCs) received either an incision or a non-tissue-injuring mechanical nociceptive stimulus ("blade") typically perceived as painful or a non-nociceptive tactile sham stimulus (blunt end of scalpel). Participants were unaware of which procedure was applied. For stress assessment, subjective and objective parameters were measured. As immediate response to the stimulus application, we found greater stress reduction after both painful stimuli (incision and blade) in BPD patients but no difference in stress decrease between the tissue-injuring incision and the non-tissue-injuring pain stimulus (blade). Compared with HCs, incision and blade were followed by greater immediate decrease of arousal in BPD patients. Our findings confirm that among BPD patients, the nociceptive input leads to stress reduction. In contrast, the impact of tissue damage on stress reduction was relatively small. In addition, the results suggest that painful stimuli lead to a greater stress reduction in BPD patients compared with HCs.
A Systematic Look at Environmental Modulation and Its Impact in Brain Development.
Sale, Alessandro
2018-01-01
Several experimental procedures are currently used to investigate the impact of the environment on brain plasticity under physiological and pathological conditions. The available methodologies are aimed at obtaining global or specific reductions or intensifications of the stimuli, with initial standardization in animal models being paralleled by translational applications to humans. More procedures can be combined together or applied in series to obtain powerful experimental paradigms, and the choice of a given setting should take into account the specific genetic background, age, and phenotypic vulnerabilities of the target subjects. Sophisticated use of environmental manipulations can increase our knowledge of the mechanisms underlying experience-dependent plasticity, opening the way for new therapies for neurodevelopmental disorders, dysfunctions of plasticity, and brain aging. Copyright © 2017 Elsevier Ltd. All rights reserved.
A research program to reduce interior noise in general aviation airplanes
NASA Technical Reports Server (NTRS)
Peschier, T. D.; Andrews, D.; Henderson, T.
1977-01-01
The relevance of KU-FRL test results in predicting (theoretically or semi-empirically) interior noise levels in general aviation aircraft was studied. As a result of this study, it was decided to make a few additions to the program. These additions are: (1) to use three (instead of two) noise sources in the plane wave tube to evaluate the influence of excitation spectrum on panel response, (2) to use theoretical and experimental data obtained in the course of the project to develop more efficient noise reduction materials (or procedures to apply these), or to develop guidelines for the design of such materials for procedures, and (3) to use nonstructural materials in the collection of specimens to be tested in the KU-FRL plane wave tube.
Pions as gluons in higher dimensions
NASA Astrophysics Data System (ADS)
Cheung, Clifford; Remmen, Grant N.; Shen, Chia-Hsien; Wen, Congkao
2018-04-01
We derive the nonlinear sigma model as a peculiar dimensional reduction of Yang-Mills theory. In this framework, pions are reformulated as higher-dimensional gluons arranged in a kinematic configuration that only probes cubic interactions. This procedure yields a purely cubic action for the nonlinear sigma model that exhibits a symmetry enforcing color-kinematics duality. Remarkably, the associated kinematic algebra originates directly from the Poincaré algebra in higher dimensions. Applying the same construction to gravity yields a new quartic action for Born-Infeld theory and, applied once more, a cubic action for the special Galileon theory. Since the nonlinear sigma model and special Galileon are subtly encoded in the cubic sectors of Yang-Mills theory and gravity, respectively, their double copy relationship is automatic.
Scientific data processing for Hipparcos
NASA Astrophysics Data System (ADS)
van der Marel, H.
1988-04-01
The scientific aims of the ESA Hipparcos astrometric satellite are reviewed, and the fundamental principles and practical implementation of the data-analysis and data-reduction procedures are discussed in detail. Hipparcos is to determine the positions and proper motions of a catalog of 110,000 stars to a limit of 12 mag with accuracy a few marcsec and obtain photometric observations of 400,000 stars (the Tycho mission). Consideration is given to the organization of the data-processing consortia FAST, NDAC, and TDAC; the basic problems of astrometry; the measurement principle; the large amounts of data to be generated during the 2.5-year mission; and the three-step iterative method to be applied (positional reconstruction and reduction to a reference great circle, spherical reconstruction, and extraction of the astrometric parameters). Diagrams and a flow chart are provided.
Spring, Michelle A
2018-04-07
Fluid accumulation is a common complication after abdominoplasty procedures, and is typically managed by the placement of post-surgical drains. Progressive tension sutures (PTS) have been shown to be an effective approach to reduce the dead space by point-wise mechanical fixation, allowing for drain-free procedures. Lysine-derived urethane surgical adhesive provides an alternative approach for mechanical fixation and reduction of dead space, and may reduce surgery time compared to PTS. This prospective, controlled, single center clinical study compared progressive tension suture wound closure technique without drains (control) to tissue adhesive wound closure technique without drains (test) during abdominoplasty surgery. The objective was to determine if lysine-derived urethane surgical adhesive is an effective alternative to PTS for drain-free abdominoplasty procedures. Patients undergoing abdominoplasty who met the established inclusion/exclusion criteria were consented and enrolled in the study. Ten PTS (control) cases were performed, followed immediately by ten tissue adhesive (test) cases. Drains were not used in any procedures. Key outcome measures included all major and minor post-surgical complications requiring any intervention, the time to place progressive tension sutures versus time for tissue adhesive application, and number of PTS attachments versus number of adhesive drops applied. Surgeries were completed over an 8-month period. No statistical differences were identified between the two groups with regard to age, BMI, dissection surface area or flap weight. No clinical seroma formation was observed in either group. In the control (PTS) group, two patients developed small areas of dermal closure suture abscess requiring removal of suture material. One control patient developed drainage and fat necrosis thought to be related to PTS above the incision and later required a scar revision. One tissue adhesive patient developed hypertrophic scars of both her breast reduction and abdominoplasty scars requiring additional treatment. The average time to place PTS in the control group was 10.7 minutes (range, 7-18 minutes) and the average number of sutures placed was 16.6 (range, 12-22 sutures). In the test group, the average time to place the tissue adhesive and hold pressure was 5.9 minutes (range 5.5-8.0 minutes). The average number of tissue adhesive drops applied was 69.6 (range: 63-78 drops). In the tissue adhesive group, both the reduction in time for flap adhesion and the increased number of adhesive points were statistically significant when compared to PTS. Lysine-derived urethane surgical adhesive was applied in less time than progressive tension sutures, even after accounting for holding pressure for 5 minutes. The tissue adhesive provided four times the number of attachment points compared to PTS, although the significance of this is not clear. There were no postoperative clinical seromas detected in either group and there were no major complications in either group. Based on these results, the use of lysine-derived urethane surgical adhesive was found to be a safe and effective alternative to progressive tension sutures to reduce seroma formation in drain-free abdominoplasty procedures.
Stress reduction through listening to Indian classical music during gastroscopy.
Kotwal, M R; Rinchhen, C Z; Ringe, V V
1998-01-01
The purpose of this study was to examine the effects of music on elevated state of anxiety as many patients become stressed and anxious during diagnostic procedures. The study was conducted on 104 consecutive patients undergoing GI endoscopy for various reasons. Patients were randomly assigned to two groups regardless of sex, age and underlying disease. One group of 54 patients were made to listen to a recorded Indian classical instrumental music before and during the procedure, while the other group of 50 patients did not. Blood pressure, heart rate and respiratory rate were recorded at the beginning of consultation and end of procedure. Perception of procedure using a three point attitude scale was assessed. Our results indicate that the background Indian classical music is efficacious in reducing psychological distress during a gastroscopic examination. We suggest that music could be applied to other medical situations as well, which tend to generate undue psychological stress and anxiety. Music, as a familiar personal and culture medium, can be used to ease anxiety, to act as distractor, to increase discomfort and pain threshold.
Applying activity-based costing to the nuclear medicine unit.
Suthummanon, Sakesun; Omachonu, Vincent K; Akcin, Mehmet
2005-08-01
Previous studies have shown the feasibility of using activity-based costing (ABC) in hospital environments. However, many of these studies discuss the general applications of ABC in health-care organizations. This research explores the potential application of ABC to the nuclear medicine unit (NMU) at a teaching hospital. The finding indicates that the current cost averages 236.11 US dollars for all procedures, which is quite different from the costs computed by using ABC. The difference is most significant with positron emission tomography scan, 463 US dollars (an increase of 96%), as well as bone scan and thyroid scan, 114 US dollars (a decrease of 52%). The result of ABC analysis demonstrates that the operational time (machine time and direct labour time) and the cost of drugs have the most influence on cost per procedure. Clearly, to reduce the cost per procedure for the NMU, the reduction in operational time and cost of drugs should be analysed. The result also indicates that ABC can be used to improve resource allocation and management. It can be an important aid in making management decisions, particularly for improving pricing practices by making costing more accurate. It also facilitates the identification of underutilized resources and related costs, leading to cost reduction. The ABC system will also help hospitals control costs, improve the quality and efficiency of the care they provide, and manage their resources better.
Ribichini, Flavio; Ferrara, Angela; Pighi, Michele; Pesarini, Gabriele; Gambaro, Alessia; Valvo, Enrico; Lupo, Antonio; Vassanelli, Corrado
2014-12-01
Renal sympathetic denervation (RSD) is emerging as a new therapeutic option for patients with severe hypertension refractory to medical therapy. Patients affected by renovascular or anatomical abnormalities have hitherto been systematically excluded from clinical trials with RSD because of concern about safety and the unknown efficacy of the procedure in this subgroup of patients. We describe the management of a case of RSD in a single-kidney patient with refractory hypertension; the patient had had a previous surgical right nephrectomy for renal cell carcinoma that subsequently required no other oncologic treatment. After multidisciplinary assessment, the patient underwent RSD. The procedure was performed through a 6F femoral access using the Symplicity™ RSD system (Medtronic, Mountain View, CA, USA). Radiofrequency was applied to the renal artery wall in 6 different points under general sedation with midazolam to control back pain caused by the procedure, that was performed without periprocedural complications. The patient was discharged 2 days later after a control of the vascular access site and routine biochemical examinations. The following 9-month follow up showed a significant reduction in blood pressure and stable renal function, without signs of renal damage. Our report confirms the feasibility of RSD in this delicate context, without evident negative effects on kidney function and with a significant reduction in blood pressure. Future studies are needed to fully clarify the value of RSD in single-kidney patients.
Code of Federal Regulations, 2010 CFR
2010-10-01
... impairment of service by domestic carriers. 63.71 Section 63.71 Telecommunication FEDERAL COMMUNICATIONS..., REDUCTION, OUTAGE AND IMPAIRMENT OF SERVICE BY COMMON CARRIERS; AND GRANTS OF RECOGNIZED PRIVATE OPERATING AGENCY STATUS Discontinuance, Reduction, Outage and Impairment § 63.71 Procedures for discontinuance...
Porcelain-metal bonding: part I. Effects of repeated baking process.
Nagasawa, S; Yoshida, T; Mizoguchi, H; Ito, M; Oshida, Y
2001-01-01
A plurality of repeated porcelain-baking procedures are normally practiced in order to achieve the final adjustment metal-porcelain restorations. By increasing the number of baking cycles, the undesired internal strain would be built-up, causing the reduction of mechanical properties and deterioration of color characteristics. However the extensive studies on such deterioration have not been done. In this study, effects of numbers (up to 10 times) of repeated baking cycles on baking shrinkage, surface roughness, bend strength, color changes and internal microstructure were investigated when opaque, body and enamel was individually applied or when a triple-player comprising of these three porcelains was repeatedly applied. It was concluded that (1) the bend strengths increased by increasing baking cycles, (2) the average surface roughness decreased by increasing number of baking procedures, (3) changes in color characteristics was very small in the Vintage halo porcelain system, and (4) since the pores entrapped in the porcelain remained even by increasing baking cycles, it is recommended to remove the surface pores before forming the next layer when handling the high viscous opaque porcelain.
NASA Astrophysics Data System (ADS)
Shojaeifar, Mohsen; Mohajerani, Ezeddin; Fathollahi, Mohammadreza
2018-01-01
Herein, we report the application of electric field assisted sintering (EFAS) procedure in dye sensitized solar cells (DSSCs). The EFAS process improved DSSC performance by enhancing optical and electrical characteristics simultaneously. The EFAS procedure is shown to be capable of reducing the TiO2 nanoparticle aggregation leading to the higher surface area for dye molecules adsorbates. Lower nanoparticle aggregation can be evidently observed by field emission scanning electron microscopy imaging. By applying an external electric field, the current density and conversion efficiency improved significantly about 30% and 45%, respectively. UV-Visible spectra of the desorbed dye molecules on the porous nanoparticles bedding confirm a higher amount of dye loading in the presence of an external electric field. Correspondingly, comprehensive J-V characteristics modeling reveals the enhancement of the diffusion coefficient by EFAS process. The proposed method can be applied to improve the efficiency of the mesostructured hybrid perovskite solar cells, photodetectors, and quantum dot-sensitized solar cells, as well as reduction of the surface area loss in all porous media.
NASA Astrophysics Data System (ADS)
Sayadi, Omid; Shamsollahi, Mohammad B.
2007-12-01
We present a new modified wavelet transform, called the multiadaptive bionic wavelet transform (MABWT), that can be applied to ECG signals in order to remove noise from them under a wide range of variations for noise. By using the definition of bionic wavelet transform and adaptively determining both the center frequency of each scale together with the[InlineEquation not available: see fulltext.]-function, the problem of desired signal decomposition is solved. Applying a new proposed thresholding rule works successfully in denoising the ECG. Moreover by using the multiadaptation scheme, lowpass noisy interference effects on the baseline of ECG will be removed as a direct task. The method was extensively clinically tested with real and simulated ECG signals which showed high performance of noise reduction, comparable to those of wavelet transform (WT). Quantitative evaluation of the proposed algorithm shows that the average SNR improvement of MABWT is 1.82 dB more than the WT-based results, for the best case. Also the procedure has largely proved advantageous over wavelet-based methods for baseline wandering cancellation, including both DC components and baseline drifts.
NASA Astrophysics Data System (ADS)
Boiko, Andrey V.; Kulik, Victor M.; Chun, Ho-Hwan; Lee, Inwon
2011-12-01
Skin frictional drag reduction efficiency of "stiff" compliant coating was investigated in a wind tunnel experiment. Flat plate compliant coating inserts were installed in a wind tunnel and the measurements of skin frictional drag and velocity field were carried out. The compliant coatings with varying viscoelastic properties had been prepared using different composition. In order to optimize the coating thickness, the most important design parameter, the dynamic viscoelastic properties had been determined experimentally. The aging of the materials (variation of their properties) during half a year was documented as well. A design procedure proposed by Kulik et al. (2008) was applied to get an optimal value for the coating thickness. Along with the drag measurement using the strain balance, velocity and pressure were measured for different coatings. The compliant coatings with the thickness h = 7mm achieved 4~5% drag reduction within a velocity range 30~40 m/s. The drag reduction mechanism of the attenuation of turbulence velocity fluctuations due to the compliant coating was demonstrated. It is envisioned that larger drag reduction effect is obtainable at higher flow velocities for high speed trains and subsonic aircrafts.
Evaluation of WES One-Dimensional Dynamic Soil Testing Procedures.
1983-06-01
relations: 18 AC - (2K +4G (6)a so I so r (6) Dividing the stress reduction Aa by a from equation (5), we obtain ana r estimate of the fractional error in...walls, the radial expansion of the soil caused by the expansion of the steel side walls, and the nonuniform stress and strain states in the sample...is applied rapidly, the stress state in the soil at the steel base may be very different from that at the top surface of the soil. With such
Subtraction method in the Second Random Phase Approximation
NASA Astrophysics Data System (ADS)
Gambacurta, Danilo
2018-02-01
We discuss the subtraction method applied to the Second Random Phase Approximation (SRPA). This method has been proposed to overcome double counting and stability issues appearing in beyond mean-field calculations. We show that the subtraction procedure leads to a considerable reduction of the SRPA downwards shift with respect to the random phase approximation (RPA) spectra and to results that are weakly cutoff dependent. Applications to the isoscalar monopole and quadrupole response in 16O and to the low-lying dipole response in 48Ca are shown and discussed.
Preclinical Feasibility of a Technology Framework for MRI-guided Iliac Angioplasty
Rube, Martin A.; Fernandez-Gutierrez, Fabiola; Cox, Benjamin F.; Holbrook, Andrew B.; Houston, J. Graeme; White, Richard D.; McLeod, Helen; Fatahi, Mahsa; Melzer, Andreas
2015-01-01
Purpose Interventional MRI has significant potential for image guidance of iliac angioplasty and related vascular procedures. A technology framework with in-room image display, control, communication and MRI-guided intervention techniques was designed and tested for its potential to provide safe, fast and efficient MRI-guided angioplasty of the iliac arteries. Methods A 1.5T MRI scanner was adapted for interactive imaging during endovascular procedures using new or modified interventional devices such as guidewires and catheters. A perfused vascular phantom was used for testing. Pre-, intra- and post-procedural visualization and measurement of vascular morphology and flow was implemented. A detailed analysis of X-Ray fluoroscopic angiography workflow was conducted and applied. Two interventional radiologists and one physician in training performed 39 procedures. All procedures were timed and analyzed. Results MRI-guided iliac angioplasty procedures were successfully performed with progressive adaptation of techniques and workflow. The workflow, setup and protocol enabled a reduction in table time for a dedicated MRI-guided procedure to 6 min 33 s with a mean procedure time of 9 min 2 s, comparable to the mean procedure time of 8 min 42 s for the standard X-Ray guided procedure. Conclusions MRI-guided iliac vascular interventions were found to be feasible and practical using this framework and optimized workflow. In particular the real-time flow analysis was found to be helpful for pre- and post-interventional assessments. Design optimization of the catheters and in vivo experiments are required before clinical evaluation. PMID:25102933
NASA Astrophysics Data System (ADS)
Deidda, Roberto; Marrocu, Marino; Pusceddu, Gabriella; Langousis, Andreas; Mascaro, Giuseppe; Caroletti, Giulio
2013-04-01
Within the activities of the EU FP7 CLIMB project (www.climb-fp7.eu), we developed downscaling procedures to reliably assess climate forcing at hydrologically relevant scales, and applied them to six representative hydrological basins located in the Mediterranean region: Riu Mannu and Noce in Italy, Chiba in Tunisia, Kocaeli in Turkey, Thau in France, and Gaza in Palestine. As a first step towards this aim, we used daily precipitation and temperature data from the gridded E-OBS project (www.ecad.eu/dailydata), as reference fields, to rank 14 Regional Climate Model (RCM) outputs from the ENSEMBLES project (http://ensembles-eu.metoffice.com). The four best performing model outputs were selected, with the additional constraint of maintaining 2 outputs obtained from running different RCMs driven by the same GCM, and 2 runs from the same RCM driven by different GCMs. For these four RCM-GCM model combinations, a set of downscaling techniques were developed and applied, for the period 1951-2100, to variables used in hydrological modeling (i.e. precipitation; mean, maximum and minimum daily temperatures; direct solar radiation, relative humidity, magnitude and direction of surface winds). The quality of the final products is discussed, together with the results obtained after applying a bias reduction procedure to daily temperature and precipitation fields.
Shi, Jun; Yuan, Hao; Xu, Bing
2013-01-01
Surgery for mandibular condyle fractures must allow direct vision of the fracture, reduce surgical trauma and achieve reduction and fixation while avoiding facial nerve injury. This prospective study was conducted to introduce a new surgical approach for open reduction and internal fixation of mandibular condyle fractures using a modified transparotid approach via the parotid mini-incision, and surgical outcomes were evaluated. The modified transparotid approach via the parotid mini-incision was applied and rigid internal fixation using a small titanium plate was carried out for 36 mandibular condyle fractures in 31 cases. Postoperative follow-up of patients ranged from 3 to 26 months; in the first 3 months after surgery, outcomes for all patients were analyzed by evaluating the degree of mouth opening, occlusal relationship, facial nerve function and results of imaging studies. The occlusal relationships were excellent in all patients and none had symptoms of intraoperative ipsilateral facial nerve injury. The mean degree of mouth opening was 4.0 (maximum 4.8 cm, minimum 3.0 cm). No mandibular deviations were noted in any patient during mouth opening. CT showed complete anatomical reduction of the mandibular condyle fracture in all patients. The modified transparotid approach via the smaller, easily concealed parotid mini-incision is minimally invasive and achieves anatomical reduction and rigid internal fixation with a simplified procedure that directly exposes the fracture site. Study results showed that this procedure is safe and feasible for treating mandibular condyle fracture, and offers a short operative path, protection of the facial nerve and satisfactory aesthetic outcomes. PMID:24386221
Chu, Mei-Lan; Chang, Hing-Chiu; Chung, Hsiao-Wen; Truong, Trong-Kha; Bashir, Mustafa R.; Chen, Nan-kuei
2014-01-01
Purpose A projection onto convex sets reconstruction of multiplexed sensitivity encoded MRI (POCSMUSE) is developed to reduce motion-related artifacts, including respiration artifacts in abdominal imaging and aliasing artifacts in interleaved diffusion weighted imaging (DWI). Theory Images with reduced artifacts are reconstructed with an iterative POCS procedure that uses the coil sensitivity profile as a constraint. This method can be applied to data obtained with different pulse sequences and k-space trajectories. In addition, various constraints can be incorporated to stabilize the reconstruction of ill-conditioned matrices. Methods The POCSMUSE technique was applied to abdominal fast spin-echo imaging data, and its effectiveness in respiratory-triggered scans was evaluated. The POCSMUSE method was also applied to reduce aliasing artifacts due to shot-to-shot phase variations in interleaved DWI data corresponding to different k-space trajectories and matrix condition numbers. Results Experimental results show that the POCSMUSE technique can effectively reduce motion-related artifacts in data obtained with different pulse sequences, k-space trajectories and contrasts. Conclusion POCSMUSE is a general post-processing algorithm for reduction of motion-related artifacts. It is compatible with different pulse sequences, and can also be used to further reduce residual artifacts in data produced by existing motion artifact reduction methods. PMID:25394325
Rolider, A; Van Houten, R
1985-01-01
The effects of a movement suppression time-out, which involved punishing any movement or verbalization while a client is in the time-out area, were evaluated in four experiments. The first experiment examined the effects of a DRO procedure and movement suppression plus DRO in suppressing self-injurious behavior in a psychotic child in three different situations. In Experiment 2, the results of the previous experiment were replicated with two dangerous behaviors in a second psychotic child. In a third experiment, movement suppression plus DRO was compared with contingent restraint in reducing inappropriate poking behavior in two settings. The movement suppression procedure eliminated poking whereas contingent restraint had little effect. In the final experiment, movement suppression time-out alone was compared with exclusionary time-out alone and simple corner time-out alone. Self-stimulation occurred at high levels during the exclusionary and simple corner time-out procedures. Self-stimulation was either suppressed or reduced during movement suppression time-out. The movement suppression time-out procedure produced a larger reduction in the target behavior in all three children. The effectiveness of the movement suppression procedure was explained in terms of the suppression of self-stimulation while the time-out procedure was being applied.
Röcker, Jessica; Schmitt, Matthias; Pasch, Ludwig; Ebert, Kristin; Grossmann, Manfred
2016-11-01
Due to the increase of sugar levels in wine grapes as one of the impacts of climate change, alcohol reduction in wines becomes a major focus of interest. This study combines the use of glucose oxidase and catalase activities with the aim of rapid conversion of glucose into non-fermentable gluconic acid. The H2O2 hydrolysing activity of purified catalase is necessary in order to stabilize glucose oxidase activity. After establishing the adequate enzyme ratio, the procedure was applied in large-scale trials (16L- and 220L-scale) of which one was conducted in a winery under industrial wine making conditions. Both enzyme activity and wine flavour were clearly influenced by the obligatory aeration in the different trials. With the enzyme treatment an alcohol reduction of 2%vol. was achieved after 30h of aeration. However the enzyme treated wines were significantly more acidic and less typical. Copyright © 2016. Published by Elsevier Ltd.
Position-dependent mass, finite-gap systems, and supersymmetry
NASA Astrophysics Data System (ADS)
Bravo, Rafael; Plyushchay, Mikhail S.
2016-05-01
The ordering problem in quantum systems with position-dependent mass (PDM) is treated by inclusion of the classically fictitious similarity transformation into the kinetic term. This provides a generation of supersymmetry with the first-order supercharges from the kinetic term alone, while inclusion of the potential term allows us also to generate nonlinear supersymmetry with higher-order supercharges. A broad class of finite-gap systems with PDM is obtained by different reduction procedures, and general results on supersymmetry generation are applied to them. We show that elliptic finite-gap systems of Lamé and Darboux-Treibich-Verdier types can be obtained by reduction to Seiffert's spherical spiral and Bernoulli lemniscate in the presence of Calogero-like or harmonic oscillator potentials, or by angular momentum reduction of a free motion on some AdS2 -related surfaces in the presence of Aharonov-Bohm flux. The limiting cases include the Higgs and Mathews-Lakshmanan oscillator models as well as a reflectionless model with PDM exploited recently in the discussion of cosmological inflationary scenarios.
An efficient algorithm using matrix methods to solve wind tunnel force-balance equations
NASA Technical Reports Server (NTRS)
Smith, D. L.
1972-01-01
An iterative procedure applying matrix methods to accomplish an efficient algorithm for automatic computer reduction of wind-tunnel force-balance data has been developed. Balance equations are expressed in a matrix form that is convenient for storing balance sensitivities and interaction coefficient values for online or offline batch data reduction. The convergence of the iterative values to a unique solution of this system of equations is investigated, and it is shown that for balances which satisfy the criteria discussed, this type of solution does occur. Methods for making sensitivity adjustments and initial load effect considerations in wind-tunnel applications are also discussed, and the logic for determining the convergence accuracy limits for the iterative solution is given. This more efficient data reduction program is compared with the technique presently in use at the NASA Langley Research Center, and computational times on the order of one-third or less are demonstrated by use of this new program.
Sibbitt, Wilmer; Sibbitt, Randy R; Michael, Adrian A; Fu, Druce I; Draeger, Hilda T; Twining, Jon M; Bankhurst, Arthur D
2006-04-01
To evaluate physician control of needle and syringe during aspiration-injection syringe procedures by comparing the new reciprocating procedure syringe to a traditional conventional syringe. Twenty-six physicians were tested for their individual ability to control the reciprocating and conventional syringes in typical aspiration-injection procedures using a novel quantitative needle-based displacement procedure model. Subsequently, the physicians performed 48 clinical aspiration-injection (arthrocentesis) procedures on 32 subjects randomized to the reciprocating or conventional syringes. Clinical outcomes included procedure time, patient pain, and operator satisfaction. Multivariate modeling methods were used to determine the experimental variables in the syringe control model most predictive of clinical outcome measures. In the model system, the reciprocating syringe significantly improved physician control of the syringe and needle, with a 66% reduction in unintended forward penetration (p < 0.001) and a 68% reduction in unintended retraction (p < 0.001). In clinical arthrocentesis, improvements were also noted: 30% reduction in procedure time (p < 0.03), 57% reduction in patient pain (p < 0.001), and a 79% increase in physician satisfaction (p < 0.001). The variables in the experimental system--unintended forward penetration, unintended retraction, and operator satisfaction--independently predicted the outcomes of procedure time, patient pain, and physician satisfaction in the clinical study (p < or = 0.001). The reciprocating syringe reduces procedure time and patient pain and improves operator satisfaction with the procedure syringe. The reciprocating syringe improves physician performance in both the validated quantitative needle-based displacement model and in real aspiration-injection syringe procedures, including arthrocentesis.
Jurado-Román, Alfonso; Sánchez-Pérez, Ignacio; Lozano Ruíz-Poveda, Fernando; López-Lluva, María T; Pinilla-Echeverri, Natalia; Moreno Arciniegas, Andrea; Agudo-Quilez, Pilar; Gil Agudo, Antonio
2016-01-01
A reduction in radiation doses at the catheterization laboratory, maintaining the quality of procedures is essential. Our objective was to analyze the results of a simple radiation reduction protocol at a high-volume interventional cardiology unit. We analyzed 1160 consecutive procedures: 580 performed before the implementation of the protocol and 580 after it. The protocol consisted in: the reduction of the number of ventriculographies and aortographies, the optimization of the collimation and the geometry of the X ray tube-patient-receptor, the use of low dose-rate fluoroscopy and the reduction of the number of cine sequences using the software "last fluoroscopy hold". There were no significant differences in clinical baseline features or in the procedural characteristics with the exception of a higher percentage of radial approach (30.7% vs 69.6%; p<0.001) and of percutaneous coronary interventions of chronic total occlusions after the implementation of the protocol (2.1% vs 6.7%; p=0,001). Angiographic success was similar during both periods (98.3% vs 99.2%; p=0.2). There were no significant differences between both periods regarding the overall duration of the procedures (26.9 vs 29.6min; p=0.14), or the fluoroscopy time (13.3 vs 13.2min; p=0.8). We observed a reduction in the percentage of procedures with ventriculography (80.9% vs 7.1%; p<0.0001) or aortography (15.4% vs 4.4%; p<0.0001), the cine runs (21.8 vs 6.9; p<0.0001) and the dose-area product (165 vs 71 Gyxcm(2); p<0.0001). With the implementation of a simple radiation reduction protocol, a 57% reduction of dose-area product was observed without a reduction in the quality or the complexity of procedures. Copyright © 2016 Elsevier Inc. All rights reserved.
42 CFR 433.120 - Procedures for reduction of FFP after reapproval review.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Claims Processing and Information Retrieval Systems § 433.120 Procedures for reduction of FFP after... significance of the unsatisfactory conditions in overall mechanized claims processing and information retrieval...
Design sensitivity analysis of rotorcraft airframe structures for vibration reduction
NASA Technical Reports Server (NTRS)
Murthy, T. Sreekanta
1987-01-01
Optimization of rotorcraft structures for vibration reduction was studied. The objective of this study is to develop practical computational procedures for structural optimization of airframes subject to steady-state vibration response constraints. One of the key elements of any such computational procedure is design sensitivity analysis. A method for design sensitivity analysis of airframes under vibration response constraints is presented. The mathematical formulation of the method and its implementation as a new solution sequence in MSC/NASTRAN are described. The results of the application of the method to a simple finite element stick model of the AH-1G helicopter airframe are presented and discussed. Selection of design variables that are most likely to bring about changes in the response at specified locations in the airframe is based on consideration of forced response strain energy. Sensitivity coefficients are determined for the selected design variable set. Constraints on the natural frequencies are also included in addition to the constraints on the steady-state response. Sensitivity coefficients for these constraints are determined. Results of the analysis and insights gained in applying the method to the airframe model are discussed. The general nature of future work to be conducted is described.
Enhanced Tobacco Control Initiative at Johns Hopkins Health System: Employee Fairness Perception.
Durrani, Shabnum; Lucik, Meg; Safeer, Richard
2018-02-01
Organizations often fail to establish a clear awareness of what employees consider fair when implementing changes to employee benefits in the workplace. In 2016, the Johns Hopkins Health System (JHHS) enhanced their tobacco control efforts. In addition to enhanced smoking cessation benefits, employees were offered an increased reduction in their insurance premiums if they were nonsmokers. To qualify for the reduction, employees participated in testing rather than relying on self-reporting as had been done in the past. The shift to testing prompted a concern by some senior management at JHHS who did not want employees to feel they were not trusted. As the program unfolded at JHHS, the four-component model of procedural justice was applied to provide a framework for reviewing the implementation of the new voluntary tobacco testing at JHHS from a fairness lens. The purpose of this article is to illustrate the application of the four-component procedural model of justice to the tobacco testing process at JHHS. As approximately 75% of employees participated in the program, the experience at JHHS can be instructive to other employers who are looking to implement changes in their workplaces and how to minimize unintended consequences with their employees.
Constant temperature hot wire anemometry data reduction procedure
NASA Technical Reports Server (NTRS)
Klopfer, G. H.
1974-01-01
The theory and data reduction procedure for constant temperature hot wire anemometry are presented. The procedure is valid for all Mach and Prandtl numbers, but limited to Reynolds numbers based on wire diameter between 0.1 and 300. The fluids are limited to gases which approximate ideal gas behavior. Losses due to radiation, free convection and conduction are included.
Wang, William; Guo, L Ray; Martland, Anne Marie; Feng, Xiao-Dong; Ma, Jie; Feng, Xi Qing
2010-04-01
Success of the modified maze procedure after valvular operation with giant atria and permanent atrial fibrillation (AF) remains suboptimal. We report an aggressive approach for these patients utilizing biatrial reduction plasty with a reef imbricate suture technique concomitantly with valvular and maze procedure for AF. From January 1999 to December 2006, 122 consecutive Chinese patients with permanent AF and biatrial enlargement who required mitral valve+/-tricuspid valve (TV) surgery underwent aggressive left atrial reduction combined with radiofrequency bipolar full maze procedure. Left atrial dimensions were measured by TTE or TEE. There were 71 women (58.1%) and 51 men (41.9%) and their mean age was 45+/-9.5 years. Mean duration of AF was 48.4+/-21.4 months. All patients underwent left atrial reduction plasty with reef imbricate suture technique and full maze procedure. Their preoperative left atria measured 64+/-12 mm in the enlarged left atria (ELA) group and 86+/-17 mm in the giant left atria (GLA). Mitral valve replacement (MVR) combined with TV repair was performed in 102 patients (83%) while 21 patients underwent MVRs combined with aortic valve replacements (17%). Sixty-six (54%) patients required additional procedures and 61 (50%) of the patients also underwent left atrial appendage clot evacuation. Postoperative left atrial size was reduced to 49+/-8 mm (ELA) and 51+/-11 mm (GLA), respectively (P<0.05). Ninety-three of 122 (76%) patients were restored in normal sinus rhythm after one year clinical follow-up. Aggressive biatrial reduction plasty combined with full maze procedure is an effective treatment for patients with permanent AF undergoing concomitant valvular surgery. Further studies utilizing the reef imbricate suture technique for atrial reduction need to subsequently be evaluated.
Bonding Cu to Al2O3 with Bi-B-Zn Oxide Glass Via Oxidation-Reduction Reaction
NASA Astrophysics Data System (ADS)
Chen, Jianqiang; Li, Yufeng; Miao, Weiliang; Mai, Chengle; Li, Mingyu
2018-01-01
Bonding Cu on Al2O3 is a key and difficult technology applied in high-power semiconductor devices. A method proposed in this work investigates bonding with a kind of Bi-B-Zn oxide glass powder paste as a solder. Oxidation-reduction reactions between the Cu plate and the solder took place and generated Bi metal during the joining procedure. With an increase in the joining temperature, the tensile strength increased due to the increase of Bi metal formation. The Bi metal played an important role in joining Cu and Al2O3 because of its much better wettability on Cu than that of the oxides. A compound ZnAl2O4 was observed to form between the Al2O3 ceramic and oxide layer, which strengthened the bond.
Polynomial reduction and evaluation of tree- and loop-level CHY amplitudes
Zlotnikov, Michael
2016-08-24
We develop a polynomial reduction procedure that transforms any gauge fixed CHY amplitude integrand for n scattering particles into a σ-moduli multivariate polynomial of what we call the standard form. We show that a standard form polynomial must have a specific ladder type monomial structure, which has finite size at any n, with highest multivariate degree given by (n – 3)(n – 4)/2. This set of monomials spans a complete basis for polynomials with rational coefficients in kinematic data on the support of scattering equations. Subsequently, at tree and one-loop level, we employ the global residue theorem to derive amore » prescription that evaluates any CHY amplitude by means of collecting simple residues at infinity only. Furthermore, the prescription is then applied explicitly to some tree and one-loop amplitude examples.« less
Giacomino, Agnese; Abollino, Ornella; Malandrino, Mery; Mentasti, Edoardo
2011-03-04
Single and sequential extraction procedures are used for studying element mobility and availability in solid matrices, like soils, sediments, sludge, and airborne particulate matter. In the first part of this review we reported an overview on these procedures and described the applications of chemometric uni- and bivariate techniques and of multivariate pattern recognition techniques based on variable reduction to the experimental results obtained. The second part of the review deals with the use of chemometrics not only for the visualization and interpretation of data, but also for the investigation of the effects of experimental conditions on the response, the optimization of their values and the calculation of element fractionation. We will describe the principles of the multivariate chemometric techniques considered, the aims for which they were applied and the key findings obtained. The following topics will be critically addressed: pattern recognition by cluster analysis (CA), linear discriminant analysis (LDA) and other less common techniques; modelling by multiple linear regression (MLR); investigation of spatial distribution of variables by geostatistics; calculation of fractionation patterns by a mixture resolution method (Chemometric Identification of Substrates and Element Distributions, CISED); optimization and characterization of extraction procedures by experimental design; other multivariate techniques less commonly applied. Copyright © 2010 Elsevier B.V. All rights reserved.
Helicopter Flight Procedures for Community Noise Reduction
NASA Technical Reports Server (NTRS)
Greenwood, Eric
2017-01-01
A computationally efficient, semiempirical noise model suitable for maneuvering flight noise prediction is used to evaluate the community noise impact of practical variations on several helicopter flight procedures typical of normal operations. Turns, "quick-stops," approaches, climbs, and combinations of these maneuvers are assessed. Relatively small variations in flight procedures are shown to cause significant changes to Sound Exposure Levels over a wide area. Guidelines are developed for helicopter pilots intended to provide effective strategies for reducing the negative effects of helicopter noise on the community. Finally, direct optimization of flight trajectories is conducted to identify low noise optimal flight procedures and quantify the magnitude of community noise reductions that can be obtained through tailored helicopter flight procedures. Physically realizable optimal turns and approaches are identified that achieve global noise reductions of as much as 10 dBA Sound Exposure Level.
Macinga, David R.; Beausoleil, Christopher M.; Campbell, Esther; Mulberry, Gayle; Brady, Ann; Edmonds, Sarah L.; Arbogast, James W.
2011-01-01
A novel method has been developed for the evaluation of alcohol-based hand rubs (ABHR) that employs a hand contamination procedure that more closely simulates the in-use conditions of ABHR. Hands of human subjects were contaminated with 0.2 ml of a concentrated suspension of Serratia marcescens (ATCC 14756) to achieve baseline contamination between 8 and 9 log10 CFU/hand while allowing product to be applied to dry hands with minimal soil load. Evaluation of 1.5 ml of an ABHR gel containing 62% ethanol produced log10 reductions of 2.66 ± 0.96, 2.40 ± 0.50, 2.41 ± 0.61, and 2.33 ± 0.49 (means ± standard deviations) after 1, 3, 7, and 10 successive contamination/product application cycles. In a study comparing this low-volume contamination (LVC) method to ASTM E1174, product dry times were more realistic and log10 reductions achieved by the ABHR were significantly greater when LVC was employed (P < 0.05). These results indicate that a novel low-volume hand contamination procedure, which more closely represents ABHR use conditions, provides more realistic estimates of in-use ABHR efficacies. Based on the LVC method, log10 reductions produced by ABHR were strongly dependent on the test product application volume (P < 0.0001) but were not influenced by the alcohol concentration when it was within the range of 62 to 85% (P = 0.378). PMID:22003004
Code of Federal Regulations, 2010 CFR
2010-10-01
..., regulations and procedures that apply to the Secretary also apply to Self-Governance Tribes that purchase real... 42 Public Health 1 2010-10-01 2010-10-01 false Do Federal real property laws, regulations and procedures that apply to the Secretary also apply to Self-Governance Tribes that purchase real property with...
NASA Technical Reports Server (NTRS)
Fetterman, Timothy L.; Noor, Ahmed K.
1987-01-01
Computational procedures are presented for evaluating the sensitivity derivatives of the vibration frequencies and eigenmodes of framed structures. Both a displacement and a mixed formulation are used. The two key elements of the computational procedure are: (a) Use of dynamic reduction techniques to substantially reduce the number of degrees of freedom; and (b) Application of iterative techniques to improve the accuracy of the derivatives of the eigenmodes. The two reduction techniques considered are the static condensation and a generalized dynamic reduction technique. Error norms are introduced to assess the accuracy of the eigenvalue and eigenvector derivatives obtained by the reduction techniques. The effectiveness of the methods presented is demonstrated by three numerical examples.
CT-guided brachytherapy of prostate cancer: reduction of effective dose from X-ray examination
NASA Astrophysics Data System (ADS)
Sanin, Dmitriy B.; Biryukov, Vitaliy A.; Rusetskiy, Sergey S.; Sviridov, Pavel V.; Volodina, Tatiana V.
2014-03-01
Computed tomography (CT) is one of the most effective and informative diagnostic method. Though the number of CT scans among all radiographic procedures in the USA and European countries is 11% and 4% respectively, CT makes the highest contribution to the collective effective dose from all radiographic procedures, it is 67% in the USA and 40% in European countries [1-5]. Therefore it is necessary to understand the significance of dose value from CT imaging to a patient . Though CT dose from multiple scans and potential risk is of great concern in pediatric patients, this applies to adults as well. In this connection it is very important to develop optimal approaches to dose reduction and optimization of CT examination. International Commission on Radiological Protection (ICRP) in its publications recommends radiologists to be aware that often CT image quality is higher than it is necessary for diagnostic confidence[6], and there is a potential to reduce the dose which patient gets from CT examination [7]. In recent years many procedures, such as minimally invasive surgery, biopsy, brachytherapy and different types of ablation are carried out under guidance of computed tomography [6;7], and during a procedures multiple CT scans focusing on a specific anatomic region are performed. At the Clinics of MRRC different types of treatment for patients with prostate cancer are used, incuding conformal CT-guided brachytherapy, implantation of microsources of I into the gland under guidance of spiral CT [8]. So, the purpose of the study is to choose optimal method to reduce radiation dose from CT during CT-guided prostate brachytherapy and to obtain the image of desired quality.
Palladium Catalyzed Reduction of Nitrobenzene.
ERIC Educational Resources Information Center
Mangravite, John A.
1983-01-01
Compares two palladium (Pd/C) reducing systems to iron/tin-hydrochloric acid (Fe/HCl and Sn/HCl) reductions and suggests an efficient, clean, and inexpensive procedures for the conversion of nitrobenzene to aniline. Includes laboratory procedures used and discussion of typical results obtained. (JN)
23 CFR 669.15 - Procedure for the reduction of funds.
Code of Federal Regulations, 2010 CFR
2010-04-01
... OPERATIONS ENFORCEMENT OF HEAVY VEHICLE USE TAX § 669.15 Procedure for the reduction of funds. (a) If it... the heavy vehicle use tax under 23 U.S.C. 141(d), the Federal Highway Administrator shall make in...
Determination of $sup 241$Am in soil using an automated nuclear radiation measurement laboratory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Engstrom, D.E.; White, M.G.; Dunaway, P.B.
The recent completion of REECo's Automated Laboratory and associated software systems has provided a significant increase in capability while reducing manpower requirements. The system is designed to perform gamma spectrum analyses on the large numbers of samples required by the current Nevada Applied Ecology Group (NAEG) and Plutonium Distribution Inventory Program (PDIP) soil sampling programs while maintaining sufficient sensitivities as defined by earlier investigations of the same type. The hardware and systems are generally described in this paper, with emphasis being placed on spectrum reduction and the calibration procedures used for soil samples. (auth)
Physician Reaction to Price Changes: An Episode-of-Care Analysis
Lee, A. James; Mitchell, Janet B.
1994-01-01
Physicians may respond to fee reductions in a variety of ways. This episode-of-care analysis examines the impact of surgical fee reductions (mandated by the Omnibus Budget Reconciliation Acts [OBRAs] of 1986-87) on the overall pattern and cost of health care services provided in association with the surgical procedure itself. The study focuses on six procedure groups: cataract extractions; total hip replacement; total knee replacement; coronary artery bypass graft (CABG) surgery; upper gastrointestinal (GI) endoscopy; and prostatectomy. Only two of these procedures give significant evidence for the existence of a service volume offset to the fee reductions. PMID:10172299
NASA Astrophysics Data System (ADS)
Migliorelli, Carolina; Alonso, Joan F.; Romero, Sergio; Mañanas, Miguel A.; Nowak, Rafał; Russi, Antonio
2016-04-01
Objective. Medical intractable epilepsy is a common condition that affects 40% of epileptic patients that generally have to undergo resective surgery. Magnetoencephalography (MEG) has been increasingly used to identify the epileptogenic foci through equivalent current dipole (ECD) modeling, one of the most accepted methods to obtain an accurate localization of interictal epileptiform discharges (IEDs). Modeling requires that MEG signals are adequately preprocessed to reduce interferences, a task that has been greatly improved by the use of blind source separation (BSS) methods. MEG recordings are highly sensitive to metallic interferences originated inside the head by implanted intracranial electrodes, dental prosthesis, etc and also coming from external sources such as pacemakers or vagal stimulators. To reduce these artifacts, a BSS-based fully automatic procedure was recently developed and validated, showing an effective reduction of metallic artifacts in simulated and real signals (Migliorelli et al 2015 J. Neural Eng. 12 046001). The main objective of this study was to evaluate its effects in the detection of IEDs and ECD modeling of patients with focal epilepsy and metallic interference. Approach. A comparison between the resulting positions of ECDs was performed: without removing metallic interference; rejecting only channels with large metallic artifacts; and after BSS-based reduction. Measures of dispersion and distance of ECDs were defined to analyze the results. Main results. The relationship between the artifact-to-signal ratio and ECD fitting showed that higher values of metallic interference produced highly scattered dipoles. Results revealed a significant reduction on dispersion using the BSS-based reduction procedure, yielding feasible locations of ECDs in contrast to the other two approaches. Significance. The automatic BSS-based method can be applied to MEG datasets affected by metallic artifacts as a processing step to improve the localization of epileptic foci.
Whey protein solution coating for fat-uptake reduction in deep-fried chicken breast strips.
Dragich, Ann M; Krochta, John M
2010-01-01
This study investigated the use of whey protein, as an additional coating, in combination with basic, well-described predust, batter, and breading ingredients, for fat-uptake reduction in fried chicken. Chicken breasts were cut into strips (1 x 5 x 10 cm) and coated with wheat flour (WF) as a predust, dipped in batter, coated with WF as a breading, then dipped in 10% denatured whey protein isolate (DWPI) aqueous solution (wet basis). A WF-batter-WF treatment with no DWPI solution dip was included as a control. Coated chicken strips were deep-fried at 160 degrees C for 5 min. A Soxhlet-type extraction was performed to determine the fat content of the meat fraction of fried samples, the coating fraction of fried samples, raw chicken, and raw coating ingredients. The WF-batter-WF-10% DWPI solution had significantly lower fat uptake than the WF-batter-WF control, by 30.67% (dry basis). This article describes applied research involving fat reduction in coated deep-fried chicken. The methods used in this article were intended to achieve maximized fat reduction while maintaining a simple procedure applicable to actual food processing lines.
Reductive Augmentation of the Breast.
Chasan, Paul E
2018-06-01
Although breast reduction surgery plays an invaluable role in the correction of macromastia, it almost always results in a breast lacking in upper pole fullness and/or roundness. We present a technique of breast reduction combined with augmentation termed "reductive augmentation" to solve this problem. The technique is also extremely useful for correcting breast asymmetry, as well as revising significant pseudoptosis in the patient who has previously undergone breast augmentation with or without mastopexy. An evolution of techniques has been used to create a breast with more upper pole fullness and anterior projection in those patients desiring a more round, higher-profile appearance. Reductive augmentation is a one-stage procedure in which a breast augmentation is immediately followed by a modified superomedial pedicle breast reduction. Often, the excision of breast tissue is greater than would normally be performed with breast reduction alone. Thirty-five patients underwent reductive augmentation, of which 12 were primary surgeries and 23 were revisions. There was an average tissue removal of 255 and 227 g, respectively, per breast for the primary and revision groups. Six of the reductive augmentations were performed for gross asymmetry. Fourteen patients had a previous mastopexy, and 3 patients had a previous breast reduction. The average follow-up was 26 months. Reductive augmentation is an effective one-stage method for achieving a more round-appearing breast with upper pole fullness both in primary breast reduction candidates and in revisionary breast surgery. This technique can also be applied to those patients with significant asymmetry. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Office-based deep sedation for pediatric ophthalmologic procedures using a sedation service model.
Lalwani, Kirk; Tomlinson, Matthew; Koh, Jeffrey; Wheeler, David
2012-01-01
Aims. (1) To assess the efficacy and safety of pediatric office-based sedation for ophthalmologic procedures using a pediatric sedation service model. (2) To assess the reduction in hospital charges of this model of care delivery compared to the operating room (OR) setting for similar procedures. Background. Sedation is used to facilitate pediatric procedures and to immobilize patients for imaging and examination. We believe that the pediatric sedation service model can be used to facilitate office-based deep sedation for brief ophthalmologic procedures and examinations. Methods. After IRB approval, all children who underwent office-based ophthalmologic procedures at our institution between January 1, 2000 and July 31, 2008 were identified using the sedation service database and the electronic health record. A comparison of hospital charges between similar procedures in the operating room was performed. Results. A total of 855 procedures were reviewed. Procedure completion rate was 100% (C.I. 99.62-100). There were no serious complications or unanticipated admissions. Our analysis showed a significant reduction in hospital charges (average of $1287 per patient) as a result of absent OR and recovery unit charges. Conclusions. Pediatric ophthalmologic minor procedures can be performed using a sedation service model with significant reductions in hospital charges.
Hoos, Anne B.; Patel, Anant R.
1996-01-01
Model-adjustment procedures were applied to the combined data bases of storm-runoff quality for Chattanooga, Knoxville, and Nashville, Tennessee, to improve predictive accuracy for storm-runoff quality for urban watersheds in these three cities and throughout Middle and East Tennessee. Data for 45 storms at 15 different sites (five sites in each city) constitute the data base. Comparison of observed values of storm-runoff load and event-mean concentration to the predicted values from the regional regression models for 10 constituents shows prediction errors, as large as 806,000 percent. Model-adjustment procedures, which combine the regional model predictions with local data, are applied to improve predictive accuracy. Standard error of estimate after model adjustment ranges from 67 to 322 percent. Calibration results may be biased due to sampling error in the Tennessee data base. The relatively large values of standard error of estimate for some of the constituent models, although representing significant reduction (at least 50 percent) in prediction error compared to estimation with unadjusted regional models, may be unacceptable for some applications. The user may wish to collect additional local data for these constituents and repeat the analysis, or calibrate an independent local regression model.
Oh, Dae Seok; Kang, Tae Hyung; Kim, Hyae Jin
2016-06-01
Lateral epicondylitis is a painful and functionally limiting disorder. Although lateral elbow pain is generally self-limiting, in a minority of people symptoms persist for a long time. When various conservative treatments fail, surgical approach is recommended. Surgical denervation of several nerves that innervate the lateral humeral epicondyle could be considered in patients with refractory pain because it denervates the region of pain. Pulsed radiofrequency is a minimally invasive procedure that improves chronic pain when applied to various neural tissues without causing any significant destruction and painful complication. This procedure is safe, minimally invasive, and has less risk of complications relatively compared to the surgical approach. The radial nerve can be identified as a target for pulsed radiofrequency lesioning in lateral epicondylitis. This innovative method of pulsed radiofrequency applied to the radial nerve has not been reported before. We reported on two patients with intractable lateral epicondylitis suffering from elbow pain who did not respond to nonoperative treatments, but in whom the ultrasound-guided pulsed radiofrequency neuromodulation of the radial nerve induced symptom improvement. After a successful diagnostic nerve block, radiofrequency probe adjustment around the radial nerve was performed on the lateral aspect of the distal upper arm under ultrasound guidance and multiple pulsed treatments were applied. A significant reduction in pain was reported over the follow-up period of 12 weeks.
2011-01-01
Background Mindfulness-based stress reduction (MBSR) programs are becoming increasingly common, but have not been studied in low income minority older populations. We sought to understand which parts of MBSR were most important to practicing MBSR members of this population, and to understand whether they apply their training to daily challenges. Methods We conducted three focus groups with 13 current members of an MBSR program. Participants were African American women over the age of 60 in a low-income housing residence. We tape recorded each session and subsequently used inductive content analysis to identify primary themes. Results and discussion Analysis of the focus group responses revealed three primary themes stress management, applying mindfulness, and the social support of the group meditation. The stressors they cited using MBSR with included growing older with physical pain, medical tests, financial strain, and having grandchildren with significant mental, physical, financial or legal hardships. We found that participants particularly used their MBSR training for coping with medical procedures, and managing both depression and anger. Conclusion A reflective stationary intervention delivered in-residence could be an ideal mechanism to decrease stress in low-income older adult's lives and improve their health. PMID:21627807
A review of the effect of vital teeth bleaching on the mechanical properties of tooth enamel.
Elfallah, Hunida M; Swain, Michael V
2013-09-01
Tooth whitening is considered the easiest and most cost-effective procedure for treating tooth discoloration. Contemporary bleaching agents contain hydrogen peroxide as the active ingredient. It is either applied directly or produced from its precursor, carbamide peroxide. A review of the published literature was undertaken to investigate the potential adverse effects of whitening products on dental enamel, with a focus on its mechanical properties and the influence of various parameters on study outcomes. There appear to be considerable differences in opinion as to whether changes in mechanical properties occur as a result of tooth whitening. However, the mechanical property findings of those studies appear to be related to the load applied during the indentation tests. Most studies which used loads higher than 500mN to determine enamel hardness showed no effect of bleaching, whereas those using lower loads were able to detect hardness reduction in the surface layer of enamel. In conclusion, bleaching reduces the hardness of the enamel surface of enamel, and that is more readily detected with instrumented low load testing systems. This hardness reduction may arise due to degradation or denaturation of enamel matrix proteins by the peroxide oxidation.
Fielden, Hannah G; Brown, Stephen L; Saini, Pooja; Beesley, Helen; Salmon, Peter
2017-09-01
Risk-reducing procedures can be offered to people at increased cancer risk, but many procedures can have iatrogenic effects. People therefore need to weigh risks associated with both cancer and the risk-reduction procedure in their decisions. By reviewing relevant literature on breast cancer (BC) risk reduction, we aimed to understand how women at relatively high risk of BC perceive their risk and how their risk perceptions influence their decisions about risk reduction. Synthesis of 15 qualitative studies obtained from systematic searches of SCOPUS, Web of Knowledge, PsychINFO, and Medline electronic databases (inception-June 2015). Women did not think about risk probabilistically. Instead, they allocated themselves to broad risk categories, typically influenced by their own or familial experiences of BC. In deciding about risk-reduction procedures, some women reported weighing the risks and benefits, but papers did not describe how they did so. For many women, however, an overriding wish to reduce intense worry about BC led them to choose aggressive risk-reducing procedures without such deliberation. Reasoning that categorisation is a fundamental aspect of risk perception, we argue that patients can be encouraged to develop more nuanced and accurate categorisations of their own risk through their interactions with clinicians. Empirically-based ethical reflection is required to determine whether and when it is appropriate to provide risk-reduction procedures to alleviate worry. © 2016 The Authors. Psycho-Oncology Published by John Wiley & Sons Ltd.
Vibration for Pain Reduction in a Plastic Surgery Clinic.
Eichhorn, Mitchell George; Karadsheh, Murad Jehad; Krebiehl, Johanna Ruth; Ford, Dawn Marie; Ford, Ronald D
2016-01-01
Patients can experience significant pain during routine procedures in the plastic surgery clinic. Methods for clinical pain reduction are often impractical, time-consuming, or ineffective. Vibration is a safe, inexpensive, and highly applicable modality for pain reduction that can be readily utilized for a wide variety of procedures. This study evaluated the use of vibration as a viable pain-reduction strategy in the clinical plastic surgery setting. Patients requiring at least 2 consecutive procedures that are considered painful were enrolled in the study. These included injections, staple removal, and suture removal. In the same patient, one half of the procedures were performed without vibration and the other half with vibration. After completing the procedures, the patients rated their pain with vibration and without vibration. The patient and the researcher also described the experience with a short questionnaire. Twenty-eight patients were enrolled in the study. Patients reported significantly less pain on the Numeric Rating Scale pain scale when vibration was used compared with the control group (p < .001). The average pain score was 3.46 without vibration and 1.93 with vibration, and vibration with injections resulted in the greatest improvement. Eighty-six percent of the patients claimed that vibration significantly reduced their pain. Vibration is an effective method of pain reduction. It significantly reduces the pain experienced by patients during minor office procedures. Given its practicality and ease of use, it is a welcome tool in the plastic surgery clinic.
NASA Astrophysics Data System (ADS)
Mehn, Dora; Morasso, Carlo; Vanna, Renzo; Schiumarini, Domitilla; Bedoni, Marzia; Ciceri, Fabio; Gramatica, Furio
2014-03-01
The Wilms tumor gene (WT1) is a biomarker overexpressed in more than 90% of acute myeloid leukemia patients. Fast and sensitive detection of the WT1 in blood samples would allow monitoring of the minimal residual disease during clinical remission and would permit early detection of a potential relapse in acute myeloid leukemia. In this work, Surface Enhanced Raman Spectroscopy (SERS) based detection of the WT1 sequence using bifunctional, magnetic core - gold shell nanoparticles is presented. The classical co-precipitation method was applied to generate magnetic nanoparticles which were coated with a gold shell after modification with aminopropyltriethoxy silane and subsequent deposition of gold nanoparticle seeds. Simple hydroquinone based reduction procedure was applied for the shell growing in water based reaction mixture at room temperature. Thiolated ssDNA probes of the WT1 sequence were immobilized as capture oligonucleotides on the gold surface. Malachite green was applied both for testing the amplification performance of the core-shell colloidal SERS substrate and also as label dye of the target DNA sequence. The SERS enhancer efficacy of the core-shell nanomaterial was compared with the efficacy of classical spherical gold particles produced using the conventional citrate reduction method. The core-shell particles were found not only to provide an opportunity for facile separation in a heterogeneous reaction system but also to be superior regarding robustness as SERS enhancers.
Surgeon specialization and operative mortality in United States: retrospective analysis
Dalton, Maurice; Cutler, David M; Birkmeyer, John D; Chandra, Amitabh
2016-01-01
Objective To measure the association between a surgeon’s degree of specialization in a specific procedure and patient mortality. Design Retrospective analysis of Medicare data. Setting US patients aged 66 or older enrolled in traditional fee for service Medicare. Participants 25 152 US surgeons who performed one of eight procedures (carotid endarterectomy, coronary artery bypass grafting, valve replacement, abdominal aortic aneurysm repair, lung resection, cystectomy, pancreatic resection, or esophagectomy) on 695 987 patients in 2008-13. Main outcome measure Relative risk reduction in risk adjusted and volume adjusted 30 day operative mortality between surgeons in the bottom quarter and top quarter of surgeon specialization (defined as the number of times the surgeon performed the specific procedure divided by his/her total operative volume across all procedures). Results For all four cardiovascular procedures and two out of four cancer resections, a surgeon’s degree of specialization was a significant predictor of operative mortality independent of the number of times he or she performed that procedure: carotid endarterectomy (relative risk reduction between bottom and top quarter of surgeons 28%, 95% confidence interval 0% to 48%); coronary artery bypass grafting (15%, 4% to 25%); valve replacement (46%, 37% to 53%); abdominal aortic aneurysm repair (42%, 29% to 53%); lung resection (28%, 5% to 46%); and cystectomy (41%, 8% to 63%). In five procedures (carotid endarterectomy, valve replacement, lung resection, cystectomy, and esophagectomy), the relative risk reduction from surgeon specialization was greater than that from surgeon volume for that specific procedure. Furthermore, surgeon specialization accounted for 9% (coronary artery bypass grafting) to 100% (cystectomy) of the relative risk reduction otherwise attributable to volume in that specific procedure. Conclusion For several common procedures, surgeon specialization was an important predictor of operative mortality independent of volume in that specific procedure. When selecting a surgeon, patients, referring physicians, and administrators assigning operative workload may want to consider a surgeon’s procedure specific volume as well as the degree to which a surgeon specializes in that procedure. PMID:27444190
NASA Technical Reports Server (NTRS)
Palosz, W.
2003-01-01
Residual gases present in closed ampoules may affect different crystal growth processes. Their presence may affect techniques requiring low pressures and affect the crystal quality in different ways. For that reason a good understanding and control of formation of residual gases may be important for an optimum design and meaningful interpretation of crystal growth experiments. Our extensive experimental and theoretical study includes degassing of silica glass and generation of gases from various source materials. Different materials processing conditions, like outgassing under vacuum, annealing in hydrogen, resublimation, different material preparation procedures, multiple annealings, different processing times, and others were applied and their effect on the amount and composition of gas were analyzed. The experimental results were interpreted based on theoretical calculations on diffusion in silica glass and source materials and thermochemistry of the system. Procedures for a reduction of the amount of gas are also discussed.
NASA Astrophysics Data System (ADS)
Del Vescovo, D.; D'Ambrogio, W.
1995-01-01
A frequency domain method is presented to design a closed-loop control for vibration reduction flexible mechanisms. The procedure is developed on a single-link flexible arm, driven by one rotary degree of freedom servomotor, although the same technique may be applied to similar systems such as supports for aerospace antennae or solar panels. The method uses the structural frequency response functions (FRFs), thus avoiding system identification, that produces modeling uncertainties. Two closed-loops are implemented: the inner loop uses acceleration feedback with the aim of making the FRF similar to that of an equivalent rigid link; the outer loop feeds back displacements to achieve a fast positioning response and null steady state error. In both cases, the controller type is established a priori, while actual characteristics are defined by an optimisation procedure in which the relevant FRF is constrained into prescribed bounds and stability is taken into account.
Feedback control for unsteady flow and its application to the stochastic Burgers equation
NASA Technical Reports Server (NTRS)
Choi, Haecheon; Temam, Roger; Moin, Parviz; Kim, John
1993-01-01
The study applies mathematical methods of control theory to the problem of control of fluid flow with the long-range objective of developing effective methods for the control of turbulent flows. Model problems are employed through the formalism and language of control theory to present the procedure of how to cast the problem of controlling turbulence into a problem in optimal control theory. Methods of calculus of variations through the adjoint state and gradient algorithms are used to present a suboptimal control and feedback procedure for stationary and time-dependent problems. Two types of controls are investigated: distributed and boundary controls. Several cases of both controls are numerically simulated to investigate the performances of the control algorithm. Most cases considered show significant reductions of the costs to be minimized. The dependence of the control algorithm on the time-descretization method is discussed.
A primer on standards setting as it applies to surgical education and credentialing.
Cendan, Juan; Wier, Daryl; Behrns, Kevin
2013-07-01
Surgical technological advances in the past three decades have led to dramatic reductions in the morbidity associated with abdominal procedures and permanently altered the surgical practice landscape. Significant changes continue apace including surgical robotics, natural orifice-based surgery, and single-incision approaches. These disruptive technologies have on occasion been injurious to patients, and high-stakes assessment before adoption of new technologies would be reasonable. We reviewed the drivers for well-established psychometric techniques available for the standards-setting process. We present a series of examples that are relevant in the surgical domain including standards setting for knowledge and skills assessments. Defensible standards for knowledge and procedural skills will likely become part of surgical clinical practice. Understanding the methodology for determining standards should position the surgical community to assist in the process and lead within their clinical settings as standards are considered that may affect patient safety and physician credentialing.
NASA Astrophysics Data System (ADS)
Kneringer, Philipp; Dietz, Sebastian J.; Mayr, Georg J.; Zeileis, Achim
2018-04-01
Airport operations are sensitive to visibility conditions. Low-visibility events may lead to capacity reduction, delays and economic losses. Different levels of low-visibility procedures (lvp) are enacted to ensure aviation safety. A nowcast of the probabilities for each of the lvp categories helps decision makers to optimally schedule their operations. An ordered logistic regression (OLR) model is used to forecast these probabilities directly. It is applied to cold season forecasts at Vienna International Airport for lead times of 30-min out to 2 h. Model inputs are standard meteorological measurements. The skill of the forecasts is accessed by the ranked probability score. OLR outperforms persistence, which is a strong contender at the shortest lead times. The ranked probability score of the OLR is even better than the one of nowcasts from human forecasters. The OLR-based nowcasting system is computationally fast and can be updated instantaneously when new data become available.
[Lung volume reduction surgery for emphysema and bullous pulmonary emphysema].
Le Pimpec-Barthes, F; Das Neves-Pereira, J-C; Cazes, A; Arame, A; Grima, R; Hubsch, J-P; Zukerman, C; Hernigou, A; Badia, A; Bagan, P; Delclaux, C; Dusser, D; Riquet, M
2012-04-01
The improvement of respiratory symptoms for emphysematous patients by surgery is a concept that has evolved over time. Initially used for giant bullae, this surgery was then applied to patients with diffuse microbullous emphysema. The physiological and pathological concepts underlying these surgical procedures are the same in both cases: improve respiratory performance by reducing the high intrapleural pressure. The functional benefit of lung volume reduction surgery (LVRS) in the severe diffuse emphysema has been validated by the National Emphysema Treatment Trial (NETT) and the later studies which allowed to identify prognostic factors. The quality of the clinical, morphological and functional data made it possible to develop recommendations now widely used in current practice. Surgery for giant bullae occurring on little or moderately emphysematous lung is often a simpler approach but also requires specialised support to optimize its results. Copyright © 2012 Elsevier Masson SAS. All rights reserved.
Fast and inexpensive synthesis of pentacene with high yield using 6,13-pentacenequinone as precursor
NASA Astrophysics Data System (ADS)
Mota, María L.; Rodriguez, Bibiana; Carrillo, Amanda; Ambrosio, Roberto C.; Luque, Priscy A.; Mireles, Marcela; Vivaldo, Israel; Quevedo, Manuel A.
2018-02-01
Pentacene is an important semiconductor in the field of organic electronics. In this work is presented an alternative synthesis procedure to obtain pentacene from 6,13-pentacenequinone as a precursor. Synthesis of pentacene was performed in two reactions, Diels-Adler cycloaddition of 6,13-pentacenequinone followed by 6,13-pentacenequinone reduction to pentacene, employing LiAlH4 as reducing agent. The products were characterized by Fourier Transform Infrared Spectroscopy (FTIR), 1H-Nuclear Magnetic Resonance Spectroscopy (1H-NMR), X-Ray Diffraction (XRD), Thermogravimetric Analysis (TGA) and Ultraviolet-Visible Spectroscopy (UV-VIS). In this work, 6,13-pentacenequinone was synthetized with a high yield (55%) using an alternative method. The optimization process resulted in an overall reduction of reaction time while exhibiting high yield. The method presented here provides an affordable pentacene synthesis route with high purity, which can be further applied for research and development of organic electronic applications.
Kordahi, Anthony M; Hoppe, Ian C; Lee, Edward S
2015-01-01
Reduction mammoplasty is an often-performed procedure by plastic surgeons and increasingly by general surgeons. The question has been posed in both general surgical literature and plastic surgical literature as to whether this procedure should remain the domain of surgical specialists. Some general surgeons are trained in breast reductions, whereas all plastic surgeons receive training in this procedure. The National Surgical Quality Improvement Project provides a unique opportunity to compare the 2 surgical specialties in an unbiased manner in terms of preoperative comorbidities and 30-day postoperative complications. The National Surgical Quality Improvement Project database was queried for the years 2005-2012. Patients were identified as having undergone a reduction mammoplasty by Current Procedural Terminology codes. RESULTS were refined to include only females with an International Classification of Diseases, Ninth Revision, code of 611.1 (hypertrophy of breasts). Information was collected regarding age, surgical specialty performing procedure, body mass index, and other preoperative variables. The outcomes utilized were presence of superficial surgical site infection, presence of deep surgical site infection, presence of wound dehiscence, postoperative respiratory compromise, pulmonary embolism, deep vein thrombosis, perioperative transfusion, operative time, reintubation, reoperation, and length of hospital stay. During this time period, there were 6239 reduction mammaplasties performed within the National Surgical Quality Improvement Project database: 339 by general surgery and 5900 by plastic surgery. No statistical differences were detected between the 2 groups with regard to superficial wound infections, deep wound infections, organ space infections, or wound dehiscence. There were no significant differences noted between within groups with regard to systemic postoperative complications. Patients undergoing a procedure by general surgery were more likely to experience a failure of skin flaps, necessitating a return to the operative room (P < .05). Operative time was longer in procedures performed by general surgery (P < .05). Several important differences appear to exist between reduction mammaplasties performed by general surgery and plastic surgery. A focused training in reduction mammoplasty appears to be beneficial to the patient. The limitations of this study include a lack of long-term follow-up with regard to aesthetic outcome, nipple malposition, nipple sensation, and late wound sequelae.
Selective reduction of pregnancy: a legal analysis.
Hall, A
1996-01-01
This article examines the technique and legality of induced abortion of one or more fetuses in a multiple pregnancy, where the aim is the destruction of some but not all of the fetuses present (selective reduction of pregnancy). It concludes that since the legal status of the procedure in English law is unclear, it may be a criminal offence to perform selective reduction even where there is an ostensible clinical need. Moreover if the procedure is carried out negligently, and any infant damaged as a result is subsequently born alive, he or she may have a civil claim against the practitioner who carried out the procedure. PMID:8910784
Silva, F G A; de Moura, M F S F; Dourado, N; Xavier, J; Pereira, F A M; Morais, J J L; Dias, M I R; Lourenço, P J; Judas, F M
2017-08-01
Fracture characterization of human cortical bone under mode II loading was analyzed using a miniaturized version of the end-notched flexure test. A data reduction scheme based on crack equivalent concept was employed to overcome uncertainties on crack length monitoring during the test. The crack tip shear displacement was experimentally measured using digital image correlation technique to determine the cohesive law that mimics bone fracture behavior under mode II loading. The developed procedure was validated by finite element analysis using cohesive zone modeling considering a trapezoidal with bilinear softening relationship. Experimental load-displacement curves, resistance curves and crack tip shear displacement versus applied displacement were used to validate the numerical procedure. The excellent agreement observed between the numerical and experimental results reveals the appropriateness of the proposed test and procedure to characterize human cortical bone fracture under mode II loading. The proposed methodology can be viewed as a novel valuable tool to be used in parametric and methodical clinical studies regarding features (e.g., age, diseases, drugs) influencing bone shear fracture under mode II loading.
Citak, Demirhan; Tuzen, Mustafa; Soylak, Mustafa
2010-01-15
A speciation procedure based on the coprecipitation of manganese(II) with zirconium(IV) hydroxide has been developed for the investigation of levels of manganese species. The determination of manganese levels was performed by flame atomic absorption spectrometry (FAAS). Total manganese was determined after the reduction of Mn(VII) to Mn(II) by ascorbic acid. The analytical parameters including pH, amount of zirconium(IV), sample volume, etc., were investigated for the quantitative recoveries of manganese(II). The effects of matrix ions were also examined. The recoveries for manganese(II) were in the range of 95-98%. Preconcentration factor was calculated as 50. The detection limit for the analyte ions based on 3 sigma (n=21) was 0.75 microg L(-1) for Mn(II). The relative standard deviation was found to be lower than 7%. The validation of the presented procedure was performed by analysis of certified reference material having different matrices, NIST SRM 1515 (Apple Leaves) and NIST SRM 1568a (Rice Flour). The procedure was successfully applied to natural waters and food samples.
Degradation and Pathway of Tetracycline Hydrochloride in Aqueous Solution by Potassium Ferrate
Ma, Yan; Gao, Naiyun; Li, Cong
2012-01-01
Abstract In the context of water treatment, the ferrate ([FeO4]2−) ion has long been known for its strong oxidizing power and for producing a coagulant from its reduced form [i.e., Fe(III)]. However, it has not been widely applied in water treatment, because of preparation difficulties and high cost. This article describes a low-cost procedure for producing solid potassium ferrate. In this synthetic procedure, NaClO was used in place of chlorine generation; and 10 M KOH was used in place of saturated KOH in the previous procedures. In addition, this study investigated the reactions of potassium ferrate with tetracycline hydrochloride (TC) at different pH and molar ratios. Results showed that the optimal pH range for TC degradation was pH 9–10, and TC could be mostly removed by Fe(VI) in 60 s. However, results showed >70% of TC degraded and <15% of dissolved organic carbon (DOC) reduction at molar ratio of 1:20. The main degradation pathway of TC is proposed based on the experimental data. PMID:22566741
Degradation and Pathway of Tetracycline Hydrochloride in Aqueous Solution by Potassium Ferrate.
Ma, Yan; Gao, Naiyun; Li, Cong
2012-05-01
In the context of water treatment, the ferrate ([FeO(4)](2-)) ion has long been known for its strong oxidizing power and for producing a coagulant from its reduced form [i.e., Fe(III)]. However, it has not been widely applied in water treatment, because of preparation difficulties and high cost. This article describes a low-cost procedure for producing solid potassium ferrate. In this synthetic procedure, NaClO was used in place of chlorine generation; and 10 M KOH was used in place of saturated KOH in the previous procedures. In addition, this study investigated the reactions of potassium ferrate with tetracycline hydrochloride (TC) at different pH and molar ratios. Results showed that the optimal pH range for TC degradation was pH 9-10, and TC could be mostly removed by Fe(VI) in 60 s. However, results showed >70% of TC degraded and <15% of dissolved organic carbon (DOC) reduction at molar ratio of 1:20. The main degradation pathway of TC is proposed based on the experimental data.
Lin, P.-S.; Chiou, B.; Abrahamson, N.; Walling, M.; Lee, C.-T.; Cheng, C.-T.
2011-01-01
In this study, we quantify the reduction in the standard deviation for empirical ground-motion prediction models by removing ergodic assumption.We partition the modeling error (residual) into five components, three of which represent the repeatable source-location-specific, site-specific, and path-specific deviations from the population mean. A variance estimation procedure of these error components is developed for use with a set of recordings from earthquakes not heavily clustered in space.With most source locations and propagation paths sampled only once, we opt to exploit the spatial correlation of residuals to estimate the variances associated with the path-specific and the source-location-specific deviations. The estimation procedure is applied to ground-motion amplitudes from 64 shallow earthquakes in Taiwan recorded at 285 sites with at least 10 recordings per site. The estimated variance components are used to quantify the reduction in aleatory variability that can be used in hazard analysis for a single site and for a single path. For peak ground acceleration and spectral accelerations at periods of 0.1, 0.3, 0.5, 1.0, and 3.0 s, we find that the singlesite standard deviations are 9%-14% smaller than the total standard deviation, whereas the single-path standard deviations are 39%-47% smaller.
5 CFR 1303.70 - Waiver or reduction of charges.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 5 Administrative Personnel 3 2011-01-01 2011-01-01 false Waiver or reduction of charges. 1303.70 Section 1303.70 Administrative Personnel OFFICE OF MANAGEMENT AND BUDGET ADMINISTRATIVE PROCEDURES PUBLIC INFORMATION PROVISIONS OF THE ADMINISTRATIVE PROCEDURES ACT Charges for Search and Reproduction § 1303.70...
5 CFR 1303.70 - Waiver or reduction of charges.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 5 Administrative Personnel 3 2010-01-01 2010-01-01 false Waiver or reduction of charges. 1303.70 Section 1303.70 Administrative Personnel OFFICE OF MANAGEMENT AND BUDGET ADMINISTRATIVE PROCEDURES PUBLIC INFORMATION PROVISIONS OF THE ADMINISTRATIVE PROCEDURES ACT Charges for Search and Reproduction § 1303.70...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gettings, M.B.
A blower-door-directed infiltration retrofit procedure was field tested on 18 homes in south central Wisconsin. The procedure, developed by the Wisconsin Energy Conservation Corporation, includes recommended retrofit techniques as well as criteria for estimating the amount of cost-effective work to be performed on a house. A recommended expenditure level and target air leakage reduction, in air changes per hour at 50 Pascal (ACH50), are determined from the initial leakage rate measured. The procedure produced an average 16% reduction in air leakage rate. For the 7 houses recommended for retrofit, 89% of the targeted reductions were accomplished with 76% of themore » recommended expenditures. The average cost of retrofits per house was reduced by a factor of four compared with previous programs. The average payback period for recommended retrofits was 4.4 years, based on predicted energy savings computed from achieved air leakage reductions. Although exceptions occurred, the procedure's 8 ACH50 minimum initial leakage rate for advising retrofits to be performed appeared a good choice, based on cost-effective air leakage reduction. Houses with initial rates of 7 ACH50 or below consistently required substantially higher costs to achieve significant air leakage reductions. No statistically significant average annual energy savings was detected as a result of the infiltration retrofits. Average measured savings were -27 therm per year, indicating an increase in energy use, with a 90% confidence interval of 36 therm. Measured savings for individual houses varied widely in both positive and negative directions, indicating that factors not considered affected the results. Large individual confidence intervals indicate a need to increase the accuracy of such measurements as well as understand the factors which may cause such disparity. Recommendations for the procedure include more extensive training of retrofit crews, checks for minimum air exchange rates to insure air quality, and addition of the basic cost of determining the initial leakage rate to the recommended expenditure level. Recommendations for the field test of the procedure include increasing the number of houses in the sample, more timely examination of metered data to detect anomalies, and the monitoring of indoor air temperature. Though not appropriate in a field test of a procedure, further investigation into the effects of air leakage rate reductions on heating loads needs to be performed.« less
The effect of zoledronate-containing primer on dentin bonding of a universal adhesive.
Zenobi, Walter; Feitosa, Victor Pinheiro; Moura, Maria Elisa Martins; D'arcangelo, Camillo; Rodrigues, Lidiany Karla de Azevedo; Sauro, Salvatore
2018-01-01
To evaluate the bonding ability and nanoleakage of a universal adhesive applied to dentin pre-treated using a zoledronate-containing primer (zol-primer) before and after mechanical load cycling. Flat dentin surfaces obtained from human molars were assigned to one of the following adhesion procedures (n=6): 1-Single Bond Universal (SBU) applied in etch-and-rinse mode; 2- SBU applied as etch-and-rinse after the application of zol-primer; 3- SBU applied in self-etch strategy; 4- SBU applied as self-etch after the use of zol-primer. Half of the specimens were processed for microtensile bond strength test after 24h, while the other half part was submitted to 200,000 mechanical cycles. Further specimens were silver-impregnated and assessed for interface nanoleakage by SEM. Data were analyzed with two-way ANOVA and Tukey's test (p<0.05). At 24h evaluation, the four groups presented similar bond strengths, whilst both groups bonded with etch-and-rinse technique showed significant bond strength reduction after mechanical load (p<0.05), with the highest drop in bond strength for the specimens pre-treated with the zol-primer. No negative effects were found for self-etch strategy (p>0.05) in microtensile test. Lower nanoleakage expression was observed for etch-and-rinse specimens treated with zol-primer. However, noteworthy reduction of adhesive layer thickness was observed when combining the zol-primer with the self-etch bonding approach. It can be concluded that zol-primer should not be used along with a universal adhesive in etch-and-rinse mode, but its application before self-etch application may provide less degradation of the resin-dentin interface. Copyright © 2017 Elsevier Ltd. All rights reserved.
Müller, M; Freude, T; Stöckle, U; Kraus, T M
2017-02-01
Closed reduction and intramedullary nailing is common in diaphyseal clavicle fractures. The aim of this report is to demonstrate a surgical method with minimally invasive percutaneous reduction in cases where closed reduction fails. The procedure is associated with good cosmetic results. Percutaneous reduction using two reduction forceps enables intramedullary nailing without an open procedure. Open, multifragmented or non-dislocated fractures, oblique fractures due to postoperative dislocation or shortening risk, fracture having potential to become compound fractures, neurovascular complications, pseudoarthroses. The patient is in beach-chair position. After an incision, the nail is entered from medial, two reduction forceps are mounted percutaneously at the lateral and medial fragment. After reduction the nail is pushed forward into the lateral fragment. Thereby, the fracture hematoma is not disturbed for the most part. Early functional rehabilitation with maximal abduction and anteversion of 90° for 6 weeks. Anatomic reduction can be achieved with mild cosmetic impairment.
Marui, Akira; Tambara, Keiichi; Tadamura, Eiji; Saji, Yoshiaki; Sasahashi, Nozomu; Ikeda, Tadashi; Nishina, Takeshi; Komeda, Masashi
2007-08-01
Left atrial (LA) volume reduction surgery concomitant with the maze procedure has been reported to facilitate sinus rhythm recovery even in patients with refractory atrial fibrillation (AF) with an enlarged LA. However, it is unknown whether the procedures can also restore effective atrial function of the enlarged LA with over-stretched myocardium. The maze procedures in association with mitral valve surgery were performed to 57 AF patients with an enlarged LA (LA diameter >or=60mm). Among them, 32 patients had concomitant LA volume reduction surgery (VR group). Another 25 patients did not have the volume reduction (control group). Three months postoperatively LA end-diastolic volume (LAEDV, ml) assessed by magnetic resonance (MR) imaging was larger in the VR group than that in the control group (291+/-117 vs 223+/-81 ml, p<0.05). Postoperatively, sinus rhythm recovery rate was better (84 vs 68%, p<0.05) and LAEDV was drastically smaller (118+/-48 vs 203+/-76 ml, p<0.001) in the VR group than those in the control group. Among the patients with sinus rhythm recovery in both groups, LA contraction ejection fraction (%) improved in the VR group but not in the control group (22.3+/-7.8 vs 10.3+/-4.7%, p<0.001). The LA volume reduction surgery concomitant with the maze procedure restored contraction of the enlarged LA; however, the maze procedure alone did not restore LA contraction in spite of successful sinus rhythm recovery. LA volume reduction surgery may be desirable to the patients with refractory AF with over-stretched LA.
Atieh, M A; Alsabeeha, N; Tawse-Smith, A; Payne, A G T
2016-08-01
Several clinical trials describe the effectiveness of xenogeneic collagen matrix (XCM) as an alternative option to surgical mucogingival procedures for the treatment of marginal tissue recession and augmentation of insufficient zones of keratinized tissue (KT). The aim of this systematic review and meta-analysis was to evaluate the clinical and patient-centred outcomes of XCM compared to other mucogingival procedures. Applying guidelines of the Preferred Reporting Items for Systematic Reviews and Meta analyses statement, randomized controlled trials were searched for in electronic databases and complemented by hand searching. The risk of bias was assessed using the Cochrane Collaboration's Risk of Bias tool and data were analysed using statistical software. A total of 645 studies were identified, of which, six trials were included with 487 mucogingival defects in 170 participants. Overall meta-analysis showed that connective tissue graft (CTG) in conjunction with the coronally advanced flap (CAF) had a significantly higher percentage of complete/mean root coverage and mean recession reduction than XCM. Insufficient evidence was found to determine any significant differences in width of KT between XCM and CTG. The XCM had a significantly higher mean root coverage, recession reduction and gain in KT compared to CAF alone. No significant differences in patient's aesthetic satisfaction were found between XCM and CTG, except for postoperative morbidity in favour of XCM. Operating time was significantly reduced with the use of XCM compared with CTG but not with CAF alone. There is no evidence to demonstrate the effectiveness of XCM in achieving greater root coverage, recession reduction and gain in KT compared to CTG plus CAF. Superior short-term results in treating root coverage compared with CAF alone are possible. There is limited evidence that XCM may improve aesthetic satisfaction, reduce postoperative morbidity and shorten the operating time. Further long-term randomized controlled trials are required to endorse the supposed advantages of XCM. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
20 CFR 668.860 - What cash management procedures apply to INA grant funds?
Code of Federal Regulations, 2010 CFR
2010-04-01
... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false What cash management procedures apply to INA... Administrative Requirements § 668.860 What cash management procedures apply to INA grant funds? INA grantees must... implement the Cash Management Improvement Act, found at 31 CFR part 205, apply by law to most recipients of...
20 CFR 668.860 - What cash management procedures apply to INA grant funds?
Code of Federal Regulations, 2011 CFR
2011-04-01
... 20 Employees' Benefits 3 2011-04-01 2011-04-01 false What cash management procedures apply to INA... Administrative Requirements § 668.860 What cash management procedures apply to INA grant funds? INA grantees must... implement the Cash Management Improvement Act, found at 31 CFR part 205, apply by law to most recipients of...
NASA Astrophysics Data System (ADS)
Mines, Paul D.; Kaarsholm, Kamilla M. S.; Droumpali, Ariadni; Andersen, Henrik R.; Lee, Wontae; Hwang, Yuhoon
2017-09-01
Remediation of contaminated groundwater by nanoscale zero-valent iron (nZVI) is widely becoming a leading environmentally friendly solution throughout the globe. Since a wide range of various nZVI-containing materials have been developed for effective remediation, it is necessary to determine an appropriate way to terminate the reactivity of any nZVI-containing material for a practical experimental procedure. In this study, bimetallic Ni/Fe-NPs were prepared to enhance overall reduction kinetics owing to the catalytic reactivity of nickel on the surface of nZVI. We have tested several chemical strategies in order to terminate nZVI reactivity without altering the concentration of volatile compounds in the solution. The strategies include surface passivation in alkaline conditions by addition of carbonate, and consumption of nZVI by a reaction competitor. Four halogenated chemicals, trichloroethylene, 1,1,1-trichloroethane, atrazine, and 4-chlorophenol, were selected and tested as model groundwater contaminants. Addition of carbonate to passivate the nZVI surface was not effective for trichloroethylene. Nitrate and then bromate were applied to competitively consume nZVI by their faster reduction kinetics. Bromate proved to be more effective than nitrate, subsequently terminating nZVI reactivity for all four of the tested halogenated compounds. Furthermore, the suggested termination method using bromate was successfully applied to obtain trichloroethylene reduction kinetics. Herein, we report the simple and effective method to terminate the reactivity of nZVI by addition of a reducing reactivity competitor.
Strategy for the reduction of Trichloromethane residue levels in farm bulk milk.
Ryan, Siobhan; Gleeson, David; Jordan, Kieran; Furey, Ambrose; O'Sullivan, Kathleen; O'Brien, Bernadette
2013-05-01
High fat dairy products, such as butter and margarine can be contaminated during the milk production process with a residue called Trichloromethane (TCM), which results from the use of chlorine based detergent solutions. Although, TCM concentrations in Irish products are not at levels that are a public health issue, such contamination can cause marketing difficulties in countries to which Irish products are being exported. In an attempt to reduce such milk residues, a template procedure was developed, tried and tested on 43 farms (from 3 processing companies). This involved identifying farms with high TCM milk, applying corrective action in the form of advice and recommendations to reduce TCM and re-measuring milks from these farms. Trichloromethane in milk was measured by head-space gas chromatography with electron capture detector. The TCM reduction strategy proved successful in significantly reducing the levels in milk in the farms tested, e.g. TCM was reduced from 0.006 to the target of 0.002 mg/kg (P < 0.05). The strategy was then applied to farms who supplied milk to six Irish dairy processors with the objective of reducing TCM in those milks to a level of ≤ 0.002 mg/kg. Initially, milk tankers containing milks from approximately 10-15 individual farms were sampled and analysed and tankers with high TCM (>0.002 mg/kg) identified. Individual herd milks contributing to these tankers were subsequently sampled and analysed and farms supplying high TCM identified. Guidance and advice was provided to the high TCM milk suppliers and levels of TCM of these milk supplies were monitored subsequently. A significant reduction (minimum P < 0.05) in milk TCM was observed in 5 of the 6 dairy processor milks, while a numerical reduction in TCM was observed in the remaining processor milk.
NASA Technical Reports Server (NTRS)
Cancro, George J.; Tolson, Robert H.; Keating, Gerald M.
1998-01-01
The success of aerobraking by the Mars Global Surveyor (MGS) spacecraft was partly due to the analysis of MGS accelerometer data. Accelerometer data was used to determine the effect of the atmosphere on each orbit, to characterize the nature of the atmosphere, and to predict the atmosphere for future orbits. To interpret the accelerometer data, a data reduction procedure was developed to produce density estimations utilizing inputs from the spacecraft, the Navigation Team, and pre-mission aerothermodynamic studies. This data reduction procedure was based on the calculation of aerodynamic forces from the accelerometer data by considering acceleration due to gravity gradient, solar pressure, angular motion of the MGS, instrument bias, thruster activity, and a vibration component due to the motion of the damaged solar array. Methods were developed to calculate all of the acceleration components including a 4 degree of freedom dynamics model used to gain a greater understanding of the damaged solar array. The total error inherent to the data reduction procedure was calculated as a function of altitude and density considering contributions from ephemeris errors, errors in force coefficient, and instrument errors due to bias and digitization. Comparing the results from this procedure to the data of other MGS Teams has demonstrated that this procedure can quickly and accurately describe the density and vertical structure of the Martian upper atmosphere.
Maceneaney, P M; Malone, D E
2000-12-01
To design a spreadsheet program to analyse interventional radiology (IR) data rapidly produced in local research or reported in the literature using 'evidence-based medicine' (EBM) parameters of treatment benefit and harm. Microsoft Excel(TM)was used. The spreadsheet consists of three worksheets. The first shows the 'Levels of Evidence and Grades of Recommendations' that can be assigned to therapeutic studies as defined by the Oxford Centre for EBM. The second and third worksheets facilitate the EBM assessment of therapeutic benefit and harm. Validity criteria are described. These include the assessment of the adequacy of sample size in the detection of possible procedural complications. A contingency (2 x 2) table for raw data on comparative outcomes in treated patients and controls has been incorporated. Formulae for EBM calculations are related to these numerators and denominators in the spreadsheet. The parameters calculated are benefit - relative risk reduction, absolute risk reduction, number needed to treat (NNT). Harm - relative risk, relative odds, number needed to harm (NNH). Ninety-five per cent confidence intervals are calculated for all these indices. The results change automatically when the data in the therapeutic outcome cells are changed. A final section allows the user to correct the NNT or NNH in their application to individual patients. This spreadsheet can be used on desktop and palmtop computers. The MS Excel(TM)version can be downloaded via the Internet from the URL ftp://radiography.com/pub/TxHarm00.xls. A spreadsheet is useful for the rapid analysis of the clinical benefit and harm from IR procedures.
Improved definition of crustal magnetic anomalies for MAGSAT data
NASA Technical Reports Server (NTRS)
Brown, R. D.; Frawley, J. F.; Davis, W. M.; Ray, R. D.; Didwall, E.; Regan, R. D. (Principal Investigator)
1982-01-01
The routine correction of MAGSAT vector magnetometer data for external field effects such as the ring current and the daily variation by filtering long wavelength harmonics from the data is described. Separation of fields due to low altitude sources from those caused by high altitude sources is affected by means of dual harmonic expansions in the solution of Dirichlet's problem. This regression/harmonic filter procedure is applied on an orbit by orbit basis, and initial tests on MAGSAT data from orbit 1176 show reduction in external field residuals by 24.33 nT RMS in the horizontal component, and 10.95 nT RMS in the radial component.
Management of prominent ears: personal approach.
Pérez-Macias, José Manuel
2008-03-01
Various methods for correcting prominent ears have been reported. Although anterior cartilage antihelix abrasion combined with posterior retention sutures is a conventional procedure, it does not include anterior conchal cartilage abrasion and thus allows easier reduction of the condromastoid angle. A simple and effective technique is described that involves using a rasp to score the whole anterior surface of the auricular cartilage, including the concha, in combination with Mustarde-type conchal-antihelical and conchal-mastoid retention sutures. This method was applied to 342 patients (675 ears) over 23 years, who were followed up for periods varying from 18 to 24 months. Good results were obtained for all patients with minimal complications.
NASA Technical Reports Server (NTRS)
Moore, M. R.; Garfin, S. R.; Hargens, A. R.
1987-01-01
A 26-year-old man presented with ipsilateral femur and ankle fractures. The patient was treated with interlocking nail of his femur fracture, followed by open reduction and internal fixation of his ankle fracture under tourniquet control. Postoperatively, the patient developed compartment syndrome of his thigh with elevated pressures, requiring decompressive fasciotomies. This case illustrates the possible complication of treating a femur fracture with intramedullary nailing and then immediately applying a tourniquet to treat an ipsilateral extremity fracture. Because of the complication with this patient, we feel the procedure should be staged, or a tourniquet should be avoided if possible.
Amaral, Marcio Bruno Figueiredo; Bueno, Sebastião Cristian; Abdala, Icaro Buchholz; da Silveira, Roger Lanes
2017-09-01
The present study aims to describe three cases of patients inflicted by rubber bullets with severe facial fractures. In addition, a review of English-language literature involving facial fractures by rubber bullets from 1975 to 2016 was performed. This current study demonstrated that the use of the LLRBW is unsafety even when applied by police enforcements exclusively. Management of facial fractures caused by LLRBW is done in a usual manner with closed or open reduction associated with bone mini-plates or reconstruction plates when indicated. Special initial wound care should be done to avoid secondary infection and additional procedures.
Scaling up to address data science challenges
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wendelberger, Joanne R.
Statistics and Data Science provide a variety of perspectives and technical approaches for exploring and understanding Big Data. Partnerships between scientists from different fields such as statistics, machine learning, computer science, and applied mathematics can lead to innovative approaches for addressing problems involving increasingly large amounts of data in a rigorous and effective manner that takes advantage of advances in computing. Here, this article will explore various challenges in Data Science and will highlight statistical approaches that can facilitate analysis of large-scale data including sampling and data reduction methods, techniques for effective analysis and visualization of large-scale simulations, and algorithmsmore » and procedures for efficient processing.« less
Scaling up to address data science challenges
Wendelberger, Joanne R.
2017-04-27
Statistics and Data Science provide a variety of perspectives and technical approaches for exploring and understanding Big Data. Partnerships between scientists from different fields such as statistics, machine learning, computer science, and applied mathematics can lead to innovative approaches for addressing problems involving increasingly large amounts of data in a rigorous and effective manner that takes advantage of advances in computing. Here, this article will explore various challenges in Data Science and will highlight statistical approaches that can facilitate analysis of large-scale data including sampling and data reduction methods, techniques for effective analysis and visualization of large-scale simulations, and algorithmsmore » and procedures for efficient processing.« less
42 CFR 431.708 - Procedures for applying standards.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Programs for Licensing Nursing Home Administrators § 431.708 Procedures for applying standards. The agency... 42 Public Health 4 2010-10-01 2010-10-01 false Procedures for applying standards. 431.708 Section 431.708 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN...
Code of Federal Regulations, 2010 CFR
2010-04-01
..., suspension, or reduction of assistance based on information obtained from a SWICA or Federal agency. 5.236 Section 5.236 Housing and Urban Development Office of the Secretary, Department of Housing and Urban... Obtaining Income Information About Applicants and Participants § 5.236 Procedures for termination, denial...
Code of Federal Regulations, 2011 CFR
2011-04-01
..., suspension, or reduction of assistance based on information obtained from a SWICA or Federal agency. 5.236 Section 5.236 Housing and Urban Development Office of the Secretary, Department of Housing and Urban... Obtaining Income Information About Applicants and Participants § 5.236 Procedures for termination, denial...
Reduction in Force: Policy & Procedure in South Carolina School Districts.
ERIC Educational Resources Information Center
Jenkins, Robert E.; Woodson, Marvin C.
Starting from a survey of research literature and court cases, researchers conducted a study of South Carolina school districts' policies and procedures concerning reductions in force (RIFs). The literature review indicated some of the conditions necessitating RIFs (such as state financial problems), methods of avoiding RIFs, and criteria for RIF…
Surgeon specialization and operative mortality in United States: retrospective analysis.
Sahni, Nikhil R; Dalton, Maurice; Cutler, David M; Birkmeyer, John D; Chandra, Amitabh
2016-07-21
To measure the association between a surgeon's degree of specialization in a specific procedure and patient mortality. Retrospective analysis of Medicare data. US patients aged 66 or older enrolled in traditional fee for service Medicare. 25 152 US surgeons who performed one of eight procedures (carotid endarterectomy, coronary artery bypass grafting, valve replacement, abdominal aortic aneurysm repair, lung resection, cystectomy, pancreatic resection, or esophagectomy) on 695 987 patients in 2008-13. Relative risk reduction in risk adjusted and volume adjusted 30 day operative mortality between surgeons in the bottom quarter and top quarter of surgeon specialization (defined as the number of times the surgeon performed the specific procedure divided by his/her total operative volume across all procedures). For all four cardiovascular procedures and two out of four cancer resections, a surgeon's degree of specialization was a significant predictor of operative mortality independent of the number of times he or she performed that procedure: carotid endarterectomy (relative risk reduction between bottom and top quarter of surgeons 28%, 95% confidence interval 0% to 48%); coronary artery bypass grafting (15%, 4% to 25%); valve replacement (46%, 37% to 53%); abdominal aortic aneurysm repair (42%, 29% to 53%); lung resection (28%, 5% to 46%); and cystectomy (41%, 8% to 63%). In five procedures (carotid endarterectomy, valve replacement, lung resection, cystectomy, and esophagectomy), the relative risk reduction from surgeon specialization was greater than that from surgeon volume for that specific procedure. Furthermore, surgeon specialization accounted for 9% (coronary artery bypass grafting) to 100% (cystectomy) of the relative risk reduction otherwise attributable to volume in that specific procedure. For several common procedures, surgeon specialization was an important predictor of operative mortality independent of volume in that specific procedure. When selecting a surgeon, patients, referring physicians, and administrators assigning operative workload may want to consider a surgeon's procedure specific volume as well as the degree to which a surgeon specializes in that procedure. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Advances in reduction techniques for tire contact problems
NASA Technical Reports Server (NTRS)
Noor, Ahmed K.
1995-01-01
Some recent developments in reduction techniques, as applied to predicting the tire contact response and evaluating the sensitivity coefficients of the different response quantities, are reviewed. The sensitivity coefficients measure the sensitivity of the contact response to variations in the geometric and material parameters of the tire. The tire is modeled using a two-dimensional laminated anisotropic shell theory with the effects of variation in geometric and material parameters, transverse shear deformation, and geometric nonlinearities included. The contact conditions are incorporated into the formulation by using a perturbed Lagrangian approach with the fundamental unknowns consisting of the stress resultants, the generalized displacements, and the Lagrange multipliers associated with the contact conditions. The elemental arrays are obtained by using a modified two-field, mixed variational principle. For the application of reduction techniques, the tire finite element model is partitioned into two regions. The first region consists of the nodes that are likely to come in contact with the pavement, and the second region includes all the remaining nodes. The reduction technique is used to significantly reduce the degrees of freedom in the second region. The effectiveness of the computational procedure is demonstrated by a numerical example of the frictionless contact response of the space shuttle nose-gear tire, inflated and pressed against a rigid flat surface. Also, the research topics which have high potential for enhancing the effectiveness of reduction techniques are outlined.
Rathod, Rahul H; Jurgen, Brittney; Hamershock, Rose A; Friedman, Kevin G; Marshall, Audrey C; Samnaliev, Mihail; Graham, Dionne A; Jenkins, Kathy; Lock, James E; Powell, Andrew J
2017-12-01
Standardized Clinical Assessment and Management Plans (SCAMPs) are a quality improvement initiative designed to reduce unnecessary utilization, decrease practice variation, and improve patient outcomes. We created a novel methodology, the SCAMP managed episode of care (SMEOC), which encompasses multiple encounters to assess the impact of the arterial switch operation (ASO) SCAMP on total costs. All ASO SCAMP patients (dates March 2009 to July 2015) were compared to a control group of ASO patients (January 2001 to February 2009). Patients were divided into "younger" (<2 years) and "older" (2-18 years) subgroups. Utilization included all cardiology visits, tests, and procedures. Standardized costs were applied to each unit of utilization. There were 100 historical and 63 SCAMP patients in the younger subgroup, and 163 historical and 165 SCAMP patients in the older subgroup. In the younger subgroup, the SCAMP had a 28% reduction in outpatient clinic visits (P < .001), a 52% reduction in chest radiographs (P < .001), a 21% reduction in electrocardiograms (P < .001), and a 30% total reduction in costs. In the older subgroup, the SCAMP had a 21% reduction in outpatient clinic visits (P < .001), a 20% reduction in chest radiographs (P = .05), a 10% reduction in echocardiograms (P = .05), a 25% reduction in exercise stress tests (P = .01), and a 14% total reduction in costs. The total cost savings of the ASO SCAMP was $216 649 in the first 6 years of the SCAMP. There was no difference in clinical outcomes between the historical and SCAMP cohorts. SCAMPs can improve resource utilization and reduce costs after the ASO operation while maintaining quality of care. © 2017 Wiley Periodicals, Inc.
Grübel, Klaudiusz; Suschka, Jan
2015-05-01
The first step of anaerobic digestion, the hydrolysis, is regarded as the rate-limiting step in the degradation of complex organic compounds, such as waste-activated sludge (WAS). The aim of lab-scale experiments was to pre-hydrolyze the sludge by means of low intensive alkaline sludge conditioning before applying hydrodynamic disintegration, as the pre-treatment procedure. Application of both processes as a hybrid disintegration sludge technology resulted in a higher organic matter release (soluble chemical oxygen demand (SCOD)) to the liquid sludge phase compared with the effects of processes conducted separately. The total SCOD after alkalization at 9 pH (pH in the range of 8.96-9.10, SCOD = 600 mg O2/L) and after hydrodynamic (SCOD = 1450 mg O2/L) disintegration equaled to 2050 mg/L. However, due to the synergistic effect, the obtained SCOD value amounted to 2800 mg/L, which constitutes an additional chemical oxygen demand (COD) dissolution of about 35 %. Similarly, the synergistic effect after alkalization at 10 pH was also obtained. The applied hybrid pre-hydrolysis technology resulted in a disintegration degree of 28-35%. The experiments aimed at selection of the most appropriate procedures in terms of optimal sludge digestion results, including high organic matter degradation (removal) and high biogas production. The analyzed soft hybrid technology influenced the effectiveness of mesophilic/thermophilic anaerobic digestion in a positive way and ensured the sludge minimization. The adopted pre-treatment technology (alkalization + hydrodynamic cavitation) resulted in 22-27% higher biogas production and 13-28% higher biogas yield. After two stages of anaerobic digestion (mesophilic conditions (MAD) + thermophilic anaerobic digestion (TAD)), the highest total solids (TS) reduction amounted to 45.6% and was received for the following sample at 7 days MAD + 17 days TAD. About 7% higher TS reduction was noticed compared with the sample after 9 days MAD + 15 days TAD. Similar results were obtained for volatile solids (VS) reduction after two-stage anaerobic digestion. The highest decrease of VS was obtained when the first stage, the mesophilic digestion which lasted 7 days, was followed by thermophilic digestion for 17 days.
Estimated correlation matrices and portfolio optimization
NASA Astrophysics Data System (ADS)
Pafka, Szilárd; Kondor, Imre
2004-11-01
Correlations of returns on various assets play a central role in financial theory and also in many practical applications. From a theoretical point of view, the main interest lies in the proper description of the structure and dynamics of correlations, whereas for the practitioner the emphasis is on the ability of the models to provide adequate inputs for the numerous portfolio and risk management procedures used in the financial industry. The theory of portfolios, initiated by Markowitz, has suffered from the “curse of dimensions” from the very outset. Over the past decades a large number of different techniques have been developed to tackle this problem and reduce the effective dimension of large bank portfolios, but the efficiency and reliability of these procedures are extremely hard to assess or compare. In this paper, we propose a model (simulation)-based approach which can be used for the systematical testing of all these dimensional reduction techniques. To illustrate the usefulness of our framework, we develop several toy models that display some of the main characteristic features of empirical correlations and generate artificial time series from them. Then, we regard these time series as empirical data and reconstruct the corresponding correlation matrices which will inevitably contain a certain amount of noise, due to the finiteness of the time series. Next, we apply several correlation matrix estimators and dimension reduction techniques introduced in the literature and/or applied in practice. As in our artificial world the only source of error is the finite length of the time series and, in addition, the “true” model, hence also the “true” correlation matrix, are precisely known, therefore in sharp contrast with empirical studies, we can precisely compare the performance of the various noise reduction techniques. One of our recurrent observations is that the recently introduced filtering technique based on random matrix theory performs consistently well in all the investigated cases. Based on this experience, we believe that our simulation-based approach can also be useful for the systematic investigation of several related problems of current interest in finance.
Hsieh, Hong-Po; Ko, Fan-Hua; Sung, Kung-Bin
2018-04-20
An iterative curve fitting method has been applied in both simulation [J. Biomed. Opt.17, 107003 (2012)JBOPFO1083-366810.1117/1.JBO.17.10.107003] and phantom [J. Biomed. Opt.19, 077002 (2014)JBOPFO1083-366810.1117/1.JBO.19.7.077002] studies to accurately extract optical properties and the top layer thickness of a two-layered superficial tissue model from diffuse reflectance spectroscopy (DRS) data. This paper describes a hybrid two-step parameter estimation procedure to address two main issues of the previous method, including (1) high computational intensity and (2) converging to local minima. The parameter estimation procedure contained a novel initial estimation step to obtain an initial guess, which was used by a subsequent iterative fitting step to optimize the parameter estimation. A lookup table was used in both steps to quickly obtain reflectance spectra and reduce computational intensity. On simulated DRS data, the proposed parameter estimation procedure achieved high estimation accuracy and a 95% reduction of computational time compared to previous studies. Furthermore, the proposed initial estimation step led to better convergence of the following fitting step. Strategies used in the proposed procedure could benefit both the modeling and experimental data processing of not only DRS but also related approaches such as near-infrared spectroscopy.
Time Savings and Surgery Task Load Reduction in Open Intraperitoneal Onlay Mesh Fixation Procedure.
Roy, Sanjoy; Hammond, Jeffrey; Panish, Jessica; Shnoda, Pullen; Savidge, Sandy; Wilson, Mark
2015-01-01
This study assessed the reduction in surgeon stress associated with savings in procedure time for mechanical fixation of an intraperitoneal onlay mesh (IPOM) compared to a traditional suture fixation in open ventral hernia repair. Nine general surgeons performed 36 open IPOM fixation procedures in porcine model. Each surgeon conducted two mechanical (using ETHICON SECURESTRAP ™ Open) and two suture fixation procedures. Fixation time was measured using a stopwatch, and related surgeon stress was assessed using the validated SURG-TLX questionnaire. T-tests were used to compare between-group differences, and a two-sided 95% confidence interval for the difference in stress levels was established using nonparametric methodology. The mechanical fixation group demonstrated an 89.1% mean reduction in fixation time, as compared to the suture group (p < 0.00001). Surgeon stress scores measured using SURG-TLX were 55.5% lower in the mechanical compared to the suture fixation group (p < 0.001). Scores in five of the six sources of stress were significantly lower for mechanical fixation. Mechanical fixation with ETHICON SECURESTRAP ™ Open demonstrated a significant reduction in fixation time and surgeon stress, which may translate into improved operating efficiency, improved performance, improved surgeon quality of life, and reduced overall costs of the procedure.
Time Savings and Surgery Task Load Reduction in Open Intraperitoneal Onlay Mesh Fixation Procedure
Roy, Sanjoy; Hammond, Jeffrey; Panish, Jessica; Shnoda, Pullen; Savidge, Sandy; Wilson, Mark
2015-01-01
Background. This study assessed the reduction in surgeon stress associated with savings in procedure time for mechanical fixation of an intraperitoneal onlay mesh (IPOM) compared to a traditional suture fixation in open ventral hernia repair. Study Design. Nine general surgeons performed 36 open IPOM fixation procedures in porcine model. Each surgeon conducted two mechanical (using ETHICON SECURESTRAPTM Open) and two suture fixation procedures. Fixation time was measured using a stopwatch, and related surgeon stress was assessed using the validated SURG-TLX questionnaire. T-tests were used to compare between-group differences, and a two-sided 95% confidence interval for the difference in stress levels was established using nonparametric methodology. Results. The mechanical fixation group demonstrated an 89.1% mean reduction in fixation time, as compared to the suture group (p < 0.00001). Surgeon stress scores measured using SURG-TLX were 55.5% lower in the mechanical compared to the suture fixation group (p < 0.001). Scores in five of the six sources of stress were significantly lower for mechanical fixation. Conclusions. Mechanical fixation with ETHICON SECURESTRAPTM Open demonstrated a significant reduction in fixation time and surgeon stress, which may translate into improved operating efficiency, improved performance, improved surgeon quality of life, and reduced overall costs of the procedure. PMID:26240834
Drawbar Pull (DP) Procedures for Off-Road Vehicle Testing
NASA Technical Reports Server (NTRS)
Creager, Colin; Asnani, Vivake; Oravec, Heather; Woodward, Adam
2017-01-01
As NASA strives to explore the surface of the Moon and Mars, there is a continued need for improved tire and vehicle development. When tires or vehicles are being designed for off-road conditions where significant thrust generation is required, such as climbing out of craters on the Moon, it is important to use a standard test method for evaluating their tractive performance. The drawbar pull (DP) test is a way of measuring the net thrust generated by tires or a vehicle with respect to performance metrics such as travel reduction, sinkage, or power efficiency. DP testing may be done using a single tire on a traction rig, or with a set of tires on a vehicle; this report focuses on vehicle DP tests. Though vehicle DP tests have been used for decades, there are no standard procedures that apply to exploration vehicles. This report summarizes previous methods employed, shows the sensitivity of certain test parameters, and provides a body of knowledge for developing standard testing procedures. The focus of this work is on lunar applications, but these test methods can be applied to terrestrial and planetary conditions as well. Section 1.0 of this report discusses the utility of DP testing for off-road vehicle evaluation and the metrics used. Section 2.0 focuses on test-terrain preparation, using the example case of lunar terrain. There is a review of lunar terrain analogs implemented in the past and a discussion on the lunar terrain conditions created at the NASA Glenn Research Center, including methods of evaluating the terrain strength variation and consistency from test to test. Section 3.0 provides details of the vehicle test procedures. These consist of a review of past methods, a comprehensive study on the sensitivity of test parameters, and a summary of the procedures used for DP testing at Glenn.
Belanger, Catherine; Gunther-Harrington, Catherine T; Nishimura, Satoko; Oldach, Maureen S; Fousse, Samantha L; Visser, Lance C; Stern, Joshua A
2018-04-01
We aimed to evaluate safety and efficacy of high-pressure balloon valvuloplasty (HPBVP) for treatment of canine severe pulmonary valve stenosis (PS). A secondary aim was to provide pre-procedure predictors of success. Twenty-five dogs. Prospective observational study. Dogs with severe PS (echocardiographically derived trans-pulmonary peak/maximum pressure gradient (EDPG) ≥80 mmHg) were recruited. All dogs underwent echocardiography before and 20-24hrs after HPBVP using a high-pressure balloon with rated burst pressures ranging from 12 to 18 ATM. Procedural success was defined as a post-HPBVP EDPG reduction of ≥50% or reduction into at least the moderate category of PS (50-79 mmHg). Optimal result was defined as a post-procedural EDPG ≤30 mmHg. Initial median (IQR) EDPG for all dogs was 96 (88, 127) mmHg with a post-operative median of 48 (36, 65) mmHg. The median EDPG reduction provided by HPBVP was 63% (39, 68); procedural success rate was 92% (23 dogs). Optimal results were achieved in 56% (14 dogs). There were no significant correlations between EDPG reduction and valve morphology (Type A and Type B) or severity of right ventricular hypertrophy. Pulmonary valve annulus diameter was the only echocardiographic variable that was significantly correlated to EDPG reduction (p = 0.02; r = -0.46). No dog experienced any anesthetic or surgical complications, and all patients survived the procedure. In this cohort of 25 dogs with severe PS, HPBVP was safe and effective. The procedural success rate and high number of optimal results achieved with HPBVP suggest future randomized controlled trials comparing HPBVP to conventional valvuloplasty are warranted. Copyright © 2018 Elsevier B.V. All rights reserved.
Salvage of failed protein targets by reductive alkylation.
Tan, Kemin; Kim, Youngchang; Hatzos-Skintges, Catherine; Chang, Changsoo; Cuff, Marianne; Chhor, Gekleng; Osipiuk, Jerzy; Michalska, Karolina; Nocek, Boguslaw; An, Hao; Babnigg, Gyorgy; Bigelow, Lance; Joachimiak, Grazyna; Li, Hui; Mack, Jamey; Makowska-Grzyska, Magdalena; Maltseva, Natalia; Mulligan, Rory; Tesar, Christine; Zhou, Min; Joachimiak, Andrzej
2014-01-01
The growth of diffraction-quality single crystals is of primary importance in protein X-ray crystallography. Chemical modification of proteins can alter their surface properties and crystallization behavior. The Midwest Center for Structural Genomics (MCSG) has previously reported how reductive methylation of lysine residues in proteins can improve crystallization of unique proteins that initially failed to produce diffraction-quality crystals. Recently, this approach has been expanded to include ethylation and isopropylation in the MCSG protein crystallization pipeline. Applying standard methods, 180 unique proteins were alkylated and screened using standard crystallization procedures. Crystal structures of 12 new proteins were determined, including the first ethylated and the first isopropylated protein structures. In a few cases, the structures of native and methylated or ethylated states were obtained and the impact of reductive alkylation of lysine residues was assessed. Reductive methylation tends to be more efficient and produces the most alkylated protein structures. Structures of methylated proteins typically have higher resolution limits. A number of well-ordered alkylated lysine residues have been identified, which make both intermolecular and intramolecular contacts. The previous report is updated and complemented with the following new data; a description of a detailed alkylation protocol with results, structural features, and roles of alkylated lysine residues in protein crystals. These contribute to improved crystallization properties of some proteins.
Salvage of Failed Protein Targets by Reductive Alkylation
Tan, Kemin; Kim, Youngchang; Hatzos-Skintges, Catherine; Chang, Changsoo; Cuff, Marianne; Chhor, Gekleng; Osipiuk, Jerzy; Michalska, Karolina; Nocek, Boguslaw; An, Hao; Babnigg, Gyorgy; Bigelow, Lance; Joachimiak, Grazyna; Li, Hui; Mack, Jamey; Makowska-Grzyska, Magdalena; Maltseva, Natalia; Mulligan, Rory; Tesar, Christine; Zhou, Min; Joachimiak, Andrzej
2014-01-01
The growth of diffraction-quality single crystals is of primary importance in protein X-ray crystallography. Chemical modification of proteins can alter their surface properties and crystallization behavior. The Midwest Center for Structural Genomics (MCSG) has previously reported how reductive methylation of lysine residues in proteins can improve crystallization of unique proteins that initially failed to produce diffraction-quality crystals. Recently, this approach has been expanded to include ethylation and isopropylation in the MCSG protein crystallization pipeline. Applying standard methods, 180 unique proteins were alkylated and screened using standard crystallization procedures. Crystal structures of 12 new proteins were determined, including the first ethylated and the first isopropylated protein structures. In a few cases, the structures of native and methylated or ethylated states were obtained and the impact of reductive alkylation of lysine residues was assessed. Reductive methylation tends to be more efficient and produces the most alkylated protein structures. Structures of methylated proteins typically have higher resolution limits. A number of well-ordered alkylated lysine residues have been identified, which make both intermolecular and intramolecular contacts. The previous report is updated and complemented with the following new data; a description of a detailed alkylation protocol with results, structural features, and roles of alkylated lysine residues in protein crystals. These contribute to improved crystallization properties of some proteins. PMID:24590719
Defeaturing CAD models using a geometry-based size field and facet-based reduction operators.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Quadros, William Roshan; Owen, Steven James
2010-04-01
We propose a method to automatically defeature a CAD model by detecting irrelevant features using a geometry-based size field and a method to remove the irrelevant features via facet-based operations on a discrete representation. A discrete B-Rep model is first created by obtaining a faceted representation of the CAD entities. The candidate facet entities are then marked for reduction by using a geometry-based size field. This is accomplished by estimating local mesh sizes based on geometric criteria. If the field value at a facet entity goes below a user specified threshold value then it is identified as an irrelevant featuremore » and is marked for reduction. The reduction of marked facet entities is primarily performed using an edge collapse operator. Care is taken to retain a valid geometry and topology of the discrete model throughout the procedure. The original model is not altered as the defeaturing is performed on a separate discrete model. Associativity between the entities of the discrete model and that of original CAD model is maintained in order to decode the attributes and boundary conditions applied on the original CAD entities onto the mesh via the entities of the discrete model. Example models are presented to illustrate the effectiveness of the proposed approach.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kohlbrenner, R; Kolli, KP; Taylor, A
2014-06-01
Purpose: To quantify the patient radiation dose reduction achieved during transarterial chemoembolization (TACE) procedures performed in a body interventional radiology suite equipped with the Philips Allura Clarity imaging acquisition and processing platform, compared to TACE procedures performed in the same suite equipped with the Philips Allura Xper platform. Methods: Total fluoroscopy time, cumulative dose area product, and cumulative air kerma were recorded for the first 25 TACE procedures performed to treat hepatocellular carcinoma (HCC) in a Philips body interventional radiology suite equipped with Philips Allura Clarity. The same data were collected for the prior 85 TACE procedures performed to treatmore » HCC in the same suite equipped with Philips Allura Xper. Mean values from these cohorts were compared using two-tailed t tests. Results: Following installation of the Philips Allura Clarity platform, a 42.8% reduction in mean cumulative dose area product (3033.2 versus 1733.6 mGycm∧2, p < 0.0001) and a 31.2% reduction in mean cumulative air kerma (1445.4 versus 994.2 mGy, p < 0.001) was achieved compared to similar procedures performed in the same suite equipped with the Philips Allura Xper platform. Mean total fluoroscopy time was not significantly different between the two cohorts (1679.3 versus 1791.3 seconds, p = 0.41). Conclusion: This study demonstrates a significant patient radiation dose reduction during TACE procedures performed to treat HCC after a body interventional radiology suite was converted to the Philips Allura Clarity platform from the Philips Allura Xper platform. Future work will focus on evaluation of patient dose reduction in a larger cohort of patients across a broader range of procedures and in specific populations, including obese patients and pediatric patients, and comparison of image quality between the two platforms. Funding for this study was provided by Philips Healthcare, with 5% salary support provided to authors K. Pallav Kolli and Robert G. Gould for time devoted to the study. Data acquisition and analysis was performed by the authors independent of the funding source.« less
Teillant, Aude; Gandra, Sumanth; Barter, Devra; Morgan, Daniel J; Laxminarayan, Ramanan
2015-12-01
The declining efficacy of existing antibiotics potentially jeopardises outcomes in patients undergoing medical procedures. We investigated the potential consequences of increases in antibiotic resistance on the ten most common surgical procedures and immunosuppressing cancer chemotherapies that rely on antibiotic prophylaxis in the USA. We searched the published scientific literature and identified meta-analyses and reviews of randomised controlled trials or quasi-randomised controlled trials (allocation done on the basis of a pseudo-random sequence-eg, odd/even hospital number or date of birth, alternation) to estimate the efficacy of antibiotic prophylaxis in preventing infections and infection-related deaths after surgical procedures and immunosuppressing cancer chemotherapy. We varied the identified effect sizes under different scenarios of reduction in the efficacy of antibiotic prophylaxis (10%, 30%, 70%, and 100% reductions) and estimated the additional number of infections and infection-related deaths per year in the USA for each scenario. We estimated the percentage of pathogens causing infections after these procedures that are resistant to standard prophylactic antibiotics in the USA. We estimate that between 38·7% and 50·9% of pathogens causing surgical site infections and 26·8% of pathogens causing infections after chemotherapy are resistant to standard prophylactic antibiotics in the USA. A 30% reduction in the efficacy of antibiotic prophylaxis for these procedures would result in 120,000 additional surgical site infections and infections after chemotherapy per year in the USA (ranging from 40,000 for a 10% reduction in efficacy to 280,000 for a 70% reduction in efficacy), and 6300 infection-related deaths (range: 2100 for a 10% reduction in efficacy, to 15,000 for a 70% reduction). We estimated that every year, 13,120 infections (42%) after prostate biopsy are attributable to resistance to fluoroquinolones in the USA. Increasing antibiotic resistance potentially threatens the safety and efficacy of surgical procedures and immunosuppressing chemotherapy. More data are needed to establish how antibiotic prophylaxis recommendations should be modified in the context of increasing rates of resistance. DRIVE-AB Consortium. Copyright © 2015 Elsevier Ltd. All rights reserved.
Hughes, Alec; Huang, Yuexi; Schwartz, Michael L; Hynynen, Kullervo
2018-05-14
To analyze clinical data indicating a reduction in the induced energy-temperature efficiency relationship during transcranial focused ultrasound (FUS) Essential Tremor (ET) thalamotomy treatments at higher acoustic powers, establish its relationship with the spatial distribution of the focal temperature elevation, and explore its cause. A retrospective observational study of patients (n = 19) treated between July 2015 and August 2016 for (ET) by FUS thalamotomy was performed. These data were analyzed to compare the relationships between the applied power, the applied energy, the resultant peak temperature achieved in the brain, and the dispersion of the focal volume. Full ethics approval was received and all patients provided signed informed consent forms before the initiation of the study. Computer simulations, animal experiments, and clinical system tests were performed to determine the effects of skull heating, changes in brain properties and transducer acoustic output, respectively. All animal procedures were approved by the Animal Care and Use Committee and conformed to the guidelines set out by the Canadian Council on Animal Care. MATLAB was used to perform statistical analysis. The reduction in the energy efficiency relationship during treatment correlates with the increase in size of the focal volume at higher sonication powers. A linear relationship exists showing that a decrease in treatment efficiency correlates positively with an increase in the focal size over the course of treatment (P < 0.01), supporting the hypothesis of transient skull and tissue heating causing acoustic aberrations leading to a decrease in efficiency. Changes in thermal conductivity, perfusion, absorption rates in the brain, as well as ultrasound transducer acoustic output levels were found to have minimal effects on the observed reduction in efficiency. The reduction in energy-temperature efficiency during high-power FUS treatments correlated with observed increases in the size of the focal volume and is likely caused by transient changes in the tissue and skull during heating. © 2018 American Association of Physicists in Medicine.
Hadi, Jebril; Tournassat, Christophe; Ignatiadis, Ioannis; Greneche, Jean Marc; Charlet, Laurent
2013-10-01
A model was developed to describe how the 2:1 layer excess negative charge induced by the reduction of Fe(III) to Fe(II) by sodium dithionite buffered with citrate-bicarbonate is balanced and applied to nontronites. This model is based on new experimental data and extends structural interpretation introduced by a former model [36-38]. The 2:1 layer negative charge increase due to Fe(III) to Fe(II) reduction is balanced by an excess adsorption of cations in the clay interlayers and a specific sorption of H(+) from solution. Prevalence of one compensating mechanism over the other is related to the growing lattice distortion induced by structural Fe(III) reduction. At low reduction levels, cation adsorption dominates and some of the incorporated protons react with structural OH groups, leading to a dehydroxylation of the structure. Starting from a moderate reduction level, other structural changes occur, leading to a reorganisation of the octahedral and tetrahedral lattice: migration or release of cations, intense dehydroxylation and bonding of protons to undersaturated oxygen atoms. Experimental data highlight some particular properties of ferruginous smectites regarding chemical reduction. Contrary to previous assumptions, the negative layer charge of nontronites does not only increase towards a plateau value upon reduction. A peak is observed in the reduction domain. After this peak, the negative layer charge decreases upon extended reduction (>30%). The decrease is so dramatic that the layer charge of highly reduced nontronites can fall below that of its fully oxidised counterpart. Furthermore, the presence of a large amount of tetrahedral Fe seems to promote intense clay structural changes and Fe reducibility. Our newly acquired data clearly show that models currently available in the literature cannot be applied to the whole reduction range of clay structural Fe. Moreover, changes in the model normalising procedure clearly demonstrate that the investigated low tetrahedral bearing nontronites (SWa-1, GAN and NAu-1) all exhibit the same behaviour at low reduction levels. Consequently, we restricted our model to the case of moderate reduction (<30%) in low tetrahedral Fe-bearing nontronites. Our adapted model provides the relative amounts of Na(+) (p) and H(+) (ni) cations incorporated in the structure as a function of the amount of Fe reduction. Two equations enable the investigated systems to be described: p=m/(1+Kr·ω·mrel) and ni=Kr·ω·m·mrel/(1+Kr·ω·mrel); where m is the Fe(II) content, mrel, the reduction level (m/mtot), ω, the cation exchange capacity (CEC, and Kr, an empirical constant specific to the system. Copyright © 2013 Elsevier Inc. All rights reserved.
Evaluation of percutaneous ethanol injections in benign thyroid nodules.
Perez, Camila Luhm Silva; Fighera, Tayane Muniz; Miasaki, Fabiola; Mesa Junior, Cleo Otaviano; Paz Filho, Gilberto Jorge da; Graf, Hans; Carvalho, Gisah Amaral de
2014-12-01
The objective of this study was to evaluate the efficacy and safety of percutaneous ethanol injection (PEI) in the treatment of benign thyroid nodules. We evaluated 120 patients with benign thyroid nodules. Patients underwent evaluation of serum TSH and free T4, cervical ultrasound, and thyroid scintigraphy (in those with suppressed TSH levels). The application of sterile ethanol 99% was guided by ultrasound, with the injected volume amounting to one-third of the nodule volume. Response was considered complete (reduction of 90%); partial (reduction between 50 and 90%); or none (reduction of < 50%). Autonomous nodules were evaluated for normalization of TSH levels. Among the nodules studied, 30.8% were solid, 56.7% were mixed, 12.5% were cystic, and 21.6% were hyperfunctioning. The initial volume of the treated nodules ranged from 0.9 to 74.8 mL (mean 13.1 ± 12.4 mL). We performed 1-8 sessions of PEI, applying an average of 6.2 mL of ethanol for patient. After 2 years of follow-up, 17% of patients achieved a complete response (94% reduction); 53%, a partial response (70% reduction); and 30%, no response. A reduction in the volume of autonomous nodules was noted in 70% of cases, and 54% had a normalized value of TSH. The main side effect is local pain, lasting less than 24 hours in most cases. This study showed that PEI is a safe and effective procedure for treatment of benign, solid or mixed thyroid nodules. Most cases resulted in significant reduction in nodule volume, with normalization of thyroid function.
21 CFR 355.70 - Testing procedures for fluoride dentifrice drug products.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 5 2010-04-01 2010-04-01 false Testing procedures for fluoride dentifrice drug... Procedures § 355.70 Testing procedures for fluoride dentifrice drug products. (a) A fluoride dentifrice drug... tests: Enamel solubility reduction or fluoride enamel uptake. The testing procedures for these...
21 CFR 355.70 - Testing procedures for fluoride dentifrice drug products.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 5 2011-04-01 2011-04-01 false Testing procedures for fluoride dentifrice drug... Procedures § 355.70 Testing procedures for fluoride dentifrice drug products. (a) A fluoride dentifrice drug... tests: Enamel solubility reduction or fluoride enamel uptake. The testing procedures for these...
A large multicenter outcome study of female genital plastic surgery.
Goodman, Michael P; Placik, Otto J; Benson, Royal H; Miklos, John R; Moore, Robert D; Jason, Robert A; Matlock, David L; Simopoulos, Alex F; Stern, Bernard H; Stanton, Ryan A; Kolb, Susan E; Gonzalez, Federico
2010-04-01
Female Genital Plastic Surgery, a relatively new entry in the field of Cosmetic and Plastic Surgery, has promised sexual enhancement and functional and cosmetic improvement for women. Are the vulvovaginal aesthetic procedures of Labiaplasty, Vaginoplasty/Perineoplasty ("Vaginal Rejuvenation") and Clitoral Hood Reduction effective, and do they deliver on that promise? For what reason do women seek these procedures? What complications are evident, and what effects are noted regarding sexual function for women and their partners? Who should be performing these procedures, what training should they have, and what are the ethical considerations? This study was designed to produce objective, utilizable outcome data regarding FGPS. 1) Reasons for considering surgery from both patient's and physician's perspective; 2) Pre-operative sexual functioning per procedure; 3) Overall patient satisfaction per procedure; 4) Effect of procedure on patient's sexual enjoyment, per procedure; 5) Patient's perception of effect on her partner's sexual enjoyment, per procedure; 6) Complications. This cross-sectional study, including 258 women and encompassing 341 separate procedures, comes from a group of twelve gynecologists, gynecologic urologists and plastic surgeons from ten centers in eight states nationwide. 104 labiaplasties, 24 clitoral hood reductions, 49 combined labiaplasty/clitoral hood reductions, 47 vaginoplasties and/or perineoplasties, and 34 combined labiaplasty and/or reduction of the clitoral hood plus vaginoplasty/perineoplasty procedures were studied retrospectively, analyzing both patient's and physician's perception of surgical rationale, pre-operative sexual function and several outcome criteria. Combining the three groups, 91.6% of patients were satisfied with the results of their surgery after a 6-42 month follow-up. Significant subjective enhancement in sexual functioning for both women and their sexual partners was noted (p = 0.0078), especially in patients undergoing vaginal tightening/perineal support procedures. Complications were acceptable and not of major consequence. While emphasizing that these female genital plastic procedures are not performed to correct "abnormalities," as there is a wide range of normality in the external and internal female genitalia, both parous and nulliparous, many women chose to modify their vulvas and vaginas. From the results of this large study pooling data from a diverse group of experienced genital plastic surgeons, outcome in both general and sexual satisfaction appear excellent.
Dawidowicz, Andrzej L; Czapczyńska, Natalia B; Wianowska, Dorota
2013-02-01
Sea Sand Disruption Method (SSDM) is a simple and cheap sample-preparation procedure allowing the reduction of organic solvent consumption, exclusion of sample component degradation, improvement of extraction efficiency and selectivity, and elimination of additional sample clean-up and pre-concentration step before chromatographic analysis. This article deals with the possibility of SSDM application for the differentiation of essential-oils components occurring in the Scots pine (Pinus sylvestris L.) and cypress (Cupressus sempervirens L.) needles from Madrid (Spain), Laganas (Zakhyntos, Greece), Cala Morell (Menorca, Spain), Lublin (Poland), Helsinki (Finland), and Oradea (Romania). The SSDM results are related to the analogous - obtained applying two other sample preparation methods - steam distillation and Pressurized Liquid Extraction (PLE). The results presented established that the total amount and the composition of essential-oil components revealed by SSDM are equivalent or higher than those obtained by one of the most effective extraction technique, PLE. Moreover, SSDM seems to provide the most representative profile of all essential-oil components as no heat is applied. Thus, this environmentally friendly method is suggested to be used as the main extraction procedure for the differentiation of essential-oil components in conifers for scientific and industrial purposes. Copyright © 2013 Verlag Helvetica Chimica Acta AG, Zürich.
VizieR Online Data Catalog: USNO Photographic Parallaxes. I. (Monet+, 1992)
NASA Astrophysics Data System (ADS)
Monet, D. G.; Dahn, C. C.; Vrba, F. J.; Harris, H. C.; Pier, J. R.; Luginbuhl, C. B.; Ables, H. D.
2000-11-01
The U.S. Naval Observatory CCD trigonometric parallax program is described in detail, including the instrumentation employed, observing procedures followed, and reduction procedures applied. Astrometric results are presented for 72 stars ranging in apparent brightness from V=15.16 to 19.58. Photometry (V and V-I on the Kron-Cousins system) is presented for the parallax stars and for all 426 individual reference stars employed in the astrometric solutions. Corrections for differential color refraction, calibrated to the observed V-I colors, have been applied to all astrometric measures. The mean errors in the relative parallaxes range from ±0.0005" to ±0.0027" with a median value of ±0.0010". Seventeen of the 23 stars with Vtan>200km/s form a well-delineated sequence of extreme subdwarfs covering 11.5
Duprat, Romain; Desmyter, Stefanie; Rudi, De Raedt; van Heeringen, Kees; Van den Abbeele, Dirk; Tandt, Hannelore; Bakic, Jasmina; Pourtois, Gilles; Dedoncker, Josefien; Vervaet, Myriam; Van Autreve, Sara; Lemmens, Gilbert M D; Baeken, Chris
2016-08-01
Although accelerated repetitive Transcranial Magnetic Stimulation (rTMS) paradigms and intermittent Theta-burst Stimulation (iTBS) may have the potency to result in superior clinical outcomes in Treatment Resistant Depression (TRD), accelerated iTBS treatment has not yet been studied. In this registered randomized double-blind sham-controlled crossover study, spread over four successive days, 50 TRD patients received 20 iTBS sessions applied to the left dorsolateral prefrontal cortex (DLPFC). The accelerated iTBS treatment procedure was found to be safe and resulted in immediate statistically significant decreases in depressive symptoms regardless of order/type of stimulation (real/sham). While only 28% of the patients showed a 50% reduction of their initial Hamilton Depression Rating Scale score at the end of the two-week procedure, this response rate increased to 38% when assessed two weeks after the end of the sham-controlled iTBS protocol, indicating delayed clinical effects. Importantly, 30% of the responders were considered in clinical remission. We found no demographic predictors for response. Our findings indicate that only four days of accelerated iTBS treatment applied to the left DLPFC in TRD may lead to meaningful clinical responses within two weeks post stimulation. Copyright © 2016 Elsevier B.V. All rights reserved.
40 CFR 86.1869-12 - CO2 credits for off-cycle CO2-reducing technologies.
Code of Federal Regulations, 2013 CFR
2013-07-01
... where the CO2 reduction benefit of the technology is not adequately captured on the Federal Test Procedure and/or the Highway Fuel Economy Test. These technologies must have a measurable, demonstrable, and verifiable real-world CO2 reduction that occurs outside the conditions of the Federal Test Procedure and the...
Acquisition and Reduction Procedures for MOF Doppler-Magnetograms. [solar observation
NASA Technical Reports Server (NTRS)
Cacciani, Alessandro; Ricci, D.; Rosati, P.; Rhodes, Edward J., Jr.; Smith, E.; Tomczyk, Steven; Ulrich, Roger K.
1988-01-01
Defects in the first magneto-optical filter (MOF) magnetograms, particularly the problem of the apparent contamination between velocity and magnetic fields, are discussed. It is found that a correct acquisition and reduction procedure gives cleaner results. A vector magnetograph is suggested. The vector field at coronal levels is calculated, using one MOF longitudinal magnetogram.
14 CFR 382.127 - What procedures apply to stowage of battery-powered mobility aids?
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false What procedures apply to stowage of battery... What procedures apply to stowage of battery-powered mobility aids? (a) Whenever baggage compartment... a passenger's battery-powered wheelchair or other similar mobility device, including the battery, as...
34 CFR 60.2 - What procedures apply to requests for indemnification?
Code of Federal Regulations, 2010 CFR
2010-07-01
... DEPARTMENT OF EDUCATION EMPLOYEES § 60.2 What procedures apply to requests for indemnification? (a) When an employee of the Department of Education becomes aware that an action has been filed against the employee in... 34 Education 1 2010-07-01 2010-07-01 false What procedures apply to requests for indemnification...
14 CFR 382.127 - What procedures apply to stowage of battery-powered mobility aids?
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 4 2011-01-01 2011-01-01 false What procedures apply to stowage of battery... What procedures apply to stowage of battery-powered mobility aids? (a) Whenever baggage compartment... a passenger's battery-powered wheelchair or other similar mobility device, including the battery, as...
14 CFR 382.127 - What procedures apply to stowage of battery-powered mobility aids?
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 4 2013-01-01 2013-01-01 false What procedures apply to stowage of battery... What procedures apply to stowage of battery-powered mobility aids? (a) Whenever baggage compartment... a passenger's battery-powered wheelchair or other similar mobility device, including the battery, as...
14 CFR 382.127 - What procedures apply to stowage of battery-powered mobility aids?
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 4 2012-01-01 2012-01-01 false What procedures apply to stowage of battery... What procedures apply to stowage of battery-powered mobility aids? (a) Whenever baggage compartment... a passenger's battery-powered wheelchair or other similar mobility device, including the battery, as...
14 CFR 382.127 - What procedures apply to stowage of battery-powered mobility aids?
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 4 2014-01-01 2014-01-01 false What procedures apply to stowage of battery... What procedures apply to stowage of battery-powered mobility aids? (a) Whenever baggage compartment... a passenger's battery-powered wheelchair or other similar mobility device, including the battery, as...
40 CFR 1065.10 - Other procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... meet all applicable emission standards. (b) Our testing. These procedures generally apply for testing... importance of pursuing changes to the procedures: (i) Whether supplemental emission standards or other... procedures. For example, this may apply if your engine cannot operate on the specified duty cycle. In this...
40 CFR 1065.10 - Other procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... meet all applicable emission standards. (b) Our testing. These procedures generally apply for testing... importance of pursuing changes to the procedures: (i) Whether supplemental emission standards or other... procedures. For example, this may apply if your engine cannot operate on the specified duty cycle. In this...
40 CFR 1065.10 - Other procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
... meet all applicable emission standards. (b) Our testing. These procedures generally apply for testing... importance of pursuing changes to the procedures: (i) Whether supplemental emission standards or other... procedures. For example, this may apply if your engine cannot operate on the specified duty cycle. In this...
40 CFR 1065.10 - Other procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... meet all applicable emission standards. (b) Our testing. These procedures generally apply for testing... importance of pursuing changes to the procedures: (i) Whether supplemental emission standards or other... procedures. For example, this may apply if your engine cannot operate on the specified duty cycle. In this...
40 CFR 1065.10 - Other procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... meet all applicable emission standards. (b) Our testing. These procedures generally apply for testing... importance of pursuing changes to the procedures: (i) Whether supplemental emission standards or other... procedures. For example, this may apply if your engine cannot operate on the specified duty cycle. In this...
75 FR 39869 - Airworthiness Directives; Airbus Model A330-200 and A330-300 Series Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-13
... uncommanded engine 1 in flight spool down, which occurred while applying fuel gravity feed procedure, in... while applying fuel gravity feed procedure, in response to low pressure indications from all fuel boost... applying fuel gravity feed procedure, in response to low pressure indications from all fuel boost pumps, in...
Shih, Tsung-Ting; Lin, Cheng-Hsing; Hsu, I-Hsiang; Chen, Jian-Yi; Sun, Yuh-Chang
2013-11-05
We developed a selective and sensitive hyphenated system employing a microfluidic-based vapor generation (VG) system in conjunction with high-performance liquid chromatography (HPLC) separation and inductively coupled plasma-mass spectrometry (ICPMS) detection for the determination of trace inorganic selenium (Se) species. The VG system exploited poly(methyl methacrylate) (PMMA) substrates of high optical quality to fabricate a microfluidic-based photocatalyst-assisted reduction device (microfluidic-based PCARD). Moreover, to reduce the consumption of photocatalysts during analytical procedures, a microfluidic-based PCARD coated with titanium dioxide nanoparticles (nano-TiO2) was employed to avoid consecutive loading. Notably, to simplify the coating procedure and improve the stability of the coating materials, a dynamic coating method was utilized. Under the optimized conditions for the selenicals of interest, the online HPLC/TiO2-coated microfluidic-based PCARD/ICPMS system enabled us to achieve detection limits (based on 3σ) of 0.043 and 0.042 μg L(-1) for Se(IV) and Se(VI), respectively. Both Se(IV) and Se(VI) could be efficiently vaporized within 15 s, while a series of validation experiments indicated that our proposed method could be satisfactorily applied to the determination of inorganic Se species in the environmental water samples.
NASA Technical Reports Server (NTRS)
Sturgeon, R. F.; Bennett, J. A.; Etchberger, F. R.; Ferrill, R. S.; Meade, L. E.
1976-01-01
A study was conducted to evaluate the technical and economic feasibility of applying laminar flow control to the wings and empennage of long-range subsonic transport aircraft compatible with initial operation in 1985. For a design mission range of 10,186 km (5500 n mi), advanced technology laminar-flow-control (LFC) and turbulent-flow (TF) aircraft were developed for both 200 and 400-passenger payloads, and compared on the basis of production costs, direct operating costs, and fuel efficiency. Parametric analyses were conducted to establish the optimum geometry for LFC and TF aircraft, advanced LFC system concepts and arrangements were evaluated, and configuration variations maximizing the effectiveness of LFC were developed. For the final LFC aircraft, analyses were conducted to define maintenance costs and procedures, manufacturing costs and procedures, and operational considerations peculiar to LFC aircraft. Compared to the corresponding advanced technology TF transports, the 200- and 400-passenger LFC aircraft realized reductions in fuel consumption up to 28.2%, reductions in direct operating costs up to 8.4%, and improvements in fuel efficiency, in ssm/lb of fuel, up to 39.4%. Compared to current commercial transports at the design range, the LFC study aircraft demonstrate improvements in fuel efficiency up to 131%. Research and technology requirements requisite to the development of LFC transport aircraft were identified.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoon Sohn; Charles Farrar; Norman Hunter
2001-01-01
This report summarizes the analysis of fiber-optic strain gauge data obtained from a surface-effect fast patrol boat being studied by the staff at the Norwegian Defense Research Establishment (NDRE) in Norway and the Naval Research Laboratory (NRL) in Washington D.C. Data from two different structural conditions were provided to the staff at Los Alamos National Laboratory. The problem was then approached from a statistical pattern recognition paradigm. This paradigm can be described as a four-part process: (1) operational evaluation, (2) data acquisition & cleansing, (3) feature extraction and data reduction, and (4) statistical model development for feature discrimination. Given thatmore » the first two portions of this paradigm were mostly completed by the NDRE and NRL staff, this study focused on data normalization, feature extraction, and statistical modeling for feature discrimination. The feature extraction process began by looking at relatively simple statistics of the signals and progressed to using the residual errors from auto-regressive (AR) models fit to the measured data as the damage-sensitive features. Data normalization proved to be the most challenging portion of this investigation. A novel approach to data normalization, where the residual errors in the AR model are considered to be an unmeasured input and an auto-regressive model with exogenous inputs (ARX) is then fit to portions of the data exhibiting similar waveforms, was successfully applied to this problem. With this normalization procedure, a clear distinction between the two different structural conditions was obtained. A false-positive study was also run, and the procedure developed herein did not yield any false-positive indications of damage. Finally, the results must be qualified by the fact that this procedure has only been applied to very limited data samples. A more complete analysis of additional data taken under various operational and environmental conditions as well as other structural conditions is necessary before one can definitively state that the procedure is robust enough to be used in practice.« less
5 CFR 359.602 - Agency reductions in force.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Agency reductions in force. 359.602... Appointees as a Result of Reduction in Force § 359.602 Agency reductions in force. (a) Competitive procedures... removed from the SES in any reduction in force of career appointees within the agency. Such competitive...
75 FR 33570 - Magnuson-Stevens Act Provisions; Fishing Capacity Reduction Framework
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-14
.... 100330171-0232-01] RIN 0648-AY79 Magnuson-Stevens Act Provisions; Fishing Capacity Reduction Framework... regulations specifying procedures for implementing fishing capacity reduction programs (reduction programs) in... either to surrender their fishing permits including relevant fishing histories for that fishery, or...
Cure Cycle Optimization of Rapidly Cured Out-Of-Autoclave Composites.
Dong, Anqi; Zhao, Yan; Zhao, Xinqing; Yu, Qiyong
2018-03-13
Out-of-autoclave prepreg typically needs a long cure cycle to guarantee good properties as the result of low processing pressure applied. It is essential to reduce the manufacturing time, achieve real cost reduction, and take full advantage of out-of-autoclave process. The focus of this paper is to reduce the cure cycle time and production cost while maintaining high laminate quality. A rapidly cured out-of-autoclave resin and relative prepreg were independently developed. To determine a suitable rapid cure procedure for the developed prepreg, the effect of heating rate, initial cure temperature, dwelling time, and post-cure time on the final laminate quality were evaluated and the factors were then optimized. As a result, a rapid cure procedure was determined. The results showed that the resin infiltration could be completed at the end of the initial cure stage and no obvious void could be seen in the laminate at this time. The laminate could achieve good internal quality using the optimized cure procedure. The mechanical test results showed that the laminates had a fiber volume fraction of 59-60% with a final glass transition temperature of 205 °C and excellent mechanical strength especially the flexural properties.
Cure Cycle Optimization of Rapidly Cured Out-Of-Autoclave Composites
Dong, Anqi; Zhao, Yan; Zhao, Xinqing; Yu, Qiyong
2018-01-01
Out-of-autoclave prepreg typically needs a long cure cycle to guarantee good properties as the result of low processing pressure applied. It is essential to reduce the manufacturing time, achieve real cost reduction, and take full advantage of out-of-autoclave process. The focus of this paper is to reduce the cure cycle time and production cost while maintaining high laminate quality. A rapidly cured out-of-autoclave resin and relative prepreg were independently developed. To determine a suitable rapid cure procedure for the developed prepreg, the effect of heating rate, initial cure temperature, dwelling time, and post-cure time on the final laminate quality were evaluated and the factors were then optimized. As a result, a rapid cure procedure was determined. The results showed that the resin infiltration could be completed at the end of the initial cure stage and no obvious void could be seen in the laminate at this time. The laminate could achieve good internal quality using the optimized cure procedure. The mechanical test results showed that the laminates had a fiber volume fraction of 59–60% with a final glass transition temperature of 205 °C and excellent mechanical strength especially the flexural properties. PMID:29534048
Alejo, L; Corredoira, E; Sánchez-Muñoz, F; Huerga, C; Aza, Z; Plaza-Núñez, R; Serrada, A; Bret-Zurita, M; Parrón, M; Prieto-Areyano, C; Garzón-Moll, G; Madero, R; Guibelalde, E
2018-04-09
Objective: The new 2013/59 EURATOM Directive (ED) demands dosimetric optimisation procedures without undue delay. The aim of this study was to optimise paediatric conventional radiology examinations applying the ED without compromising the clinical diagnosis. Automatic dose management software (ADMS) was used to analyse 2678 studies of children from birth to 5 years of age, obtaining local diagnostic reference levels (DRLs) in terms of entrance surface air kerma. Given local DRL for infants and chest examinations exceeded the European Commission (EC) DRL, an optimisation was performed decreasing the kVp and applying the automatic control exposure. To assess the image quality, an analysis of high-contrast resolution (HCSR), signal-to-noise ratio (SNR) and figure of merit (FOM) was performed, as well as a blind test based on the generalised estimating equations method. For newborns and chest examinations, the local DRL exceeded the EC DRL by 113%. After the optimisation, a reduction of 54% was obtained. No significant differences were found in the image quality blind test. A decrease in SNR (-37%) and HCSR (-68%), and an increase in FOM (42%), was observed. ADMS allows the fast calculation of local DRLs and the performance of optimisation procedures in babies without delay. However, physical and clinical analyses of image quality remain to be needed to ensure the diagnostic integrity after the optimisation process. Advances in knowledge: ADMS are useful to detect radiation protection problems and to perform optimisation procedures in paediatric conventional imaging without undue delay, as ED requires.
NASA Astrophysics Data System (ADS)
Schlömer, Luc; Phlippen, Peter-W.; Lukas, Bernard
2017-09-01
The decommissioning of a light water reactor (LWR), which is licensed under § 7 of the German Atomic Energy Act, following the post-operational phase requires a comprehensive licensing procedure including in particular radiation protection aspects and possible impacts to the environment. Decommissioning includes essential changes in requirements for the systems and components and will mainly lead to the direct dismantling. In this context, neutron induced activation calculations for the structural components have to be carried out to predict activities in structures and to estimate future costs for conditioning and packaging. To avoid an overestimation of the radioactive inventory and to calculate the expenses for decommissioning as accurate as possible, modern state-of-the-art Monte-Carlo-Techniques (MCNP™) are applied and coupled with present-day activation and decay codes (ORIGEN-S). In this context ADVANTG is used as weight window generator for MCNP™ i. e. as variance reduction tool to speed up the calculation in deep penetration problems. In this paper the calculation procedure is described and the obtained results are presented with a validation along with measured activities and photon dose rates measured in the post-operational phase. The validation shows that the applied calculation procedure is suitable for the determination of the radioactive inventory of a nuclear power plant. Even the measured gamma dose rates in the post-operational phase at different positions in the reactor building agree within a factor of 2 to 3 with the calculation results. The obtained results are accurate and suitable to support effectively the decommissioning planning process.
Cabrera, Manuel; Galvin, Adela P.; Agrela, Francisco; Beltran, Manuel G.; Ayuso, Jesus
2016-01-01
This research is focused on analyzing the environmental pollution potential of biomass bottom ashes as individual materials, as mixtures manufactured with biomass bottom ashes and granular construction aggregates, and these mixtures treated with cement. For the environmental assessment of all of the samples and materials mentioned, the following leaching procedures have been performed: the compliance batch test of UNE-EN 12457-3:2003 for aggregates and bottom ashes; the column test according to NEN 7343:1994 for the mixtures prepared in the laboratory; and the tank test by EA NEN 7375:2004 for analyzing the behavior of mixtures after their solidification/stabilization with 5% cement. After the discussion of the data, the reduction of the pollution load of the most hazardous biomass bottom ashes after their combination with different aggregates can be confirmed, which implies their possible application in civil infrastructures, such as filler embankments and road construction layers, without negatively impacting the environment. In addition, the positive effect of the stabilization/solidification of the cement-treated mixtures with a reduction of the heavy metals that were released at the highest levels, namely As, Hg Cr, Ni, Cu, Se and Mo, was proven. PMID:28773352
Review of Van earthquakes form an orthopaedic perspective: a multicentre retrospective study.
Guner, Savas; Guner, Sukriye Ilkay; Isik, Yasemin; Gormeli, Gokay; Kalender, Ali Murat; Turktas, Ugur; Gokalp, Mehmet Ata; Gozen, Abdurrahim; Isik, Mustafa; Ozkan, Sezai; Turkozu, Tulin; Karadas, Sevdegul; Ceylan, Mehmet Fethi; Ediz, Levent; Bulut, Mehmet; Gunes, Yusuf; Gormeli, Ayse; Erturk, Cemil; Eseoglu, Metehan; Dursun, Recep
2013-01-01
This is a descriptive analysis, of victims of Turkey's October 23, 2011 and November 21, 2011 Van earthquakes. The goal of this study is investigated the injury profile of the both earthquakes in relation to musculoskeletal trauma. We retrospectively reviewed medical records of 3,965 patients admitted to in seven hospitals. A large share of these injuries were soft tissue injuries, followed by fractures, crush injuries, crush syndromes, nerve injuries, vascular injuries, compartment syndrome and joint dislocations. A total of 73 crush injuries were diagnosed and 31 of them were developed compartment syndrome. The patients with closed undisplaced fractures were treated with casting braces. For closed unstable fractures with good skin and soft-tissue conditions, open reduction and internal fixation was performed. All patients with open fracture had an external fixator applied after adequate debridement. Thirty one of 40 patients with compartment syndrome were treated by fasciotomy. For twelve of them, amputation was necessary. The most common procedure performed was debridement, followed by open reduction and internal fixation and closed reduction-casting, respectively. The results of this study may provide the basis for future development of strategy to optimise attempts at rescue and plan treatment of survivors with musculoskeletal injuries after earthquakes.
Renal denervation in a patient with Alport syndrome and rejected renal allograft.
Raju, Narayana; Lloyd, Vincent; Yalagudri, Sachin; Das, Bharati; Ravikishore, A G
2015-12-01
Renal denervation is a new intervention to treat resistant hypertension. By applying radiofrequency (RF) to renal arteries, sympathetic nerves in adventitia layer of vascular wall can be denervated. Sympathetic hyperactivity is an important contributory factor in hypertension of hemodialysis patients. Hyperactive sympathetic nervous system aggravates hypertension and it can cause complications like left ventricular hypertrophy, heart failure, arrhythmias and atherogenesis. Our report illustrates the use of renal denervation using conventional RF catheter for uncontrolled hypertension in a patient with Alport syndrome and rejected renal allograft. Progressive and sustained reduction of blood pressure was obtained post-procedure and at 24 months follow-up with antihypertensives decreased from 6 to 2 per day, thereby demonstrating the safety, feasibility, and efficacy of the procedure. There are some reports available on the usefulness of this technique in hemodialysis patients; however, there are no studies of renal denervation in patients with Alport syndrome and failed allograft situation. Copyright © 2015 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.
Residual Gases in Crystal Growth Systems
NASA Technical Reports Server (NTRS)
Palosz, W.
2003-01-01
Residual gases present in closed ampoules may affect different crystal growth processes. That seems to be particularly true under microgravity conditions where, due to weightlessness of the melt, the gases may lead to detached solidification and/or formation of voids and bubbles, as observed in the past. For that reason a good understanding and control of formation of residual gases is important for an optimum design and meaningful interpretation of crystal growth experiments. Our extensive experimental and theoretical studies of the subject, summarized in this paper, include degassing of silica glass and generation of gases from different source materials. Different materials processing conditions, like outgassing under vacuum, annealing in hydrogen, resublimation, different material preparation procedures, multiple annealings, different processing times, and others were applied and their effect on the amount and composition of gas were analyzed. The experimental results were interpreted based on theoretical calculations on diffusion in silica glass and source materials and thermochemistry of the system. Procedures for a reduction of the amount of gas are also discussed.
Wisaijohn, Thunthita; Pimkhaokham, Atiphan; Lapying, Phenkhae; Itthichaisri, Chumpot; Pannarunothai, Supasit; Igarashi, Isao; Kawabuchi, Koichi
2010-01-01
This study aimed to develop a new casemix classification system as an alternative method for the budget allocation of oral healthcare service (OHCS). Initially, the International Statistical of Diseases and Related Health Problem, 10th revision, Thai Modification (ICD-10-TM) related to OHCS was used for developing the software “Grouper”. This model was designed to allow the translation of dental procedures into eight-digit codes. Multiple regression analysis was used to analyze the relationship between the factors used for developing the model and the resource consumption. Furthermore, the coefficient of variance, reduction in variance, and relative weight (RW) were applied to test the validity. The results demonstrated that 1,624 OHCS classifications, according to the diagnoses and the procedures performed, showed high homogeneity within groups and heterogeneity between groups. Moreover, the RW of the OHCS could be used to predict and control the production costs. In conclusion, this new OHCS casemix classification has a potential use in a global decision making. PMID:20936134
Wisaijohn, Thunthita; Pimkhaokham, Atiphan; Lapying, Phenkhae; Itthichaisri, Chumpot; Pannarunothai, Supasit; Igarashi, Isao; Kawabuchi, Koichi
2010-01-01
This study aimed to develop a new casemix classification system as an alternative method for the budget allocation of oral healthcare service (OHCS). Initially, the International Statistical of Diseases and Related Health Problem, 10th revision, Thai Modification (ICD-10-TM) related to OHCS was used for developing the software "Grouper". This model was designed to allow the translation of dental procedures into eight-digit codes. Multiple regression analysis was used to analyze the relationship between the factors used for developing the model and the resource consumption. Furthermore, the coefficient of variance, reduction in variance, and relative weight (RW) were applied to test the validity. The results demonstrated that 1,624 OHCS classifications, according to the diagnoses and the procedures performed, showed high homogeneity within groups and heterogeneity between groups. Moreover, the RW of the OHCS could be used to predict and control the production costs. In conclusion, this new OHCS casemix classification has a potential use in a global decision making.
The effect of music on preprocedure anxiety in Hong Kong Chinese day patients.
Lee, David; Henderson, Amanda; Shum, David
2004-03-01
To identify the effect of music on preprocedure anxiety levels of Hong Kong Chinese patients undergoing day procedures in a local community based hospital. Pre and post-test quasi experimental design with non-random assignment. A total of 113 participants were assigned to the control group or intervention group depending on the day of their procedure. Participants' anxiety levels were measured objectively by comparing their vital signs and subjectively by the Spielberger State Trait Anxiety Scale. Participants' physiological parameters (blood pressure, pulse and respiration) and State Trait Anxiety Scale were measured at two time periods. The control group undertook the usual relaxing activities provided in the waiting room compared with the intervention group who listened to music of their own choice in reclining chairs while waiting for the procedure. The physiological parameters for both the control and intervention groups dropped significantly during the waiting period, however, only the intervention group had a significant reduction in reported anxiety levels. These results suggest that providing self-selected music to day procedure patients in the preprocedure period assists in the reduction of physiological parameters and anxiety, yet, a relaxing environment can assist in the reduction of physiological parameters. The administration of self-selected music to day procedure patients in the preprocedure period can be effective in the reduction of physiological parameters and anxiety.
NASA Technical Reports Server (NTRS)
Finley, Tom D.; Wong, Douglas T.; Tripp, John S.
1993-01-01
A newly developed technique for enhanced data reduction provides an improved procedure that allows least squares minimization to become possible between data sets with an unequal number of data points. This technique was applied in the Crew and Equipment Translation Aid (CETA) experiment on the STS-37 Shuttle flight in April 1991 to obtain the velocity profile from the acceleration data. The new technique uses a least-squares method to estimate the initial conditions and calibration constants. These initial conditions are estimated by least-squares fitting the displacements indicated by the Hall-effect sensor data to the corresponding displacements obtained from integrating the acceleration data. The velocity and displacement profiles can then be recalculated from the corresponding acceleration data using the estimated parameters. This technique, which enables instantaneous velocities to be obtained from the test data instead of only average velocities at varying discrete times, offers more detailed velocity information, particularly during periods of large acceleration or deceleration.
The 2-d CCD Data Reduction Cookbook
NASA Astrophysics Data System (ADS)
Davenhall, A. C.; Privett, G. J.; Taylor, M. B.
This cookbook presents simple recipes and scripts for reducing direct images acquired with optical CCD detectors. Using these recipes and scripts you can correct un-processed images obtained from CCDs for various instrumental effects to retrieve an accurate picture of the field of sky observed. The recipes and scripts use standard software available at all Starlink sites. The topics covered include: creating and applying bias and flat-field corrections, registering frames and creating a stack or mosaic of registered frames. Related auxiliary tasks, such as converting between different data formats, displaying images and calculating image statistics are also presented. In addition to the recipes and scripts, sufficient background material is presented to explain the procedures and techniques used. The treatment is deliberately practical rather than theoretical, in keeping with the aim of providing advice on the actual reduction of observations. Additional material outlines some of the differences between using conventional optical CCDs and the similar arrays used to observe at infrared wavelengths.
NASA Astrophysics Data System (ADS)
Bogiatzis, P.; Ishii, M.; Davis, T. A.
2016-12-01
Seismic tomography inverse problems are among the largest high-dimensional parameter estimation tasks in Earth science. We show how combinatorics and graph theory can be used to analyze the structure of such problems, and to effectively decompose them into smaller ones that can be solved efficiently by means of the least squares method. In combination with recent high performance direct sparse algorithms, this reduction in dimensionality allows for an efficient computation of the model resolution and covariance matrices using limited resources. Furthermore, we show that a new sparse singular value decomposition method can be used to obtain the complete spectrum of the singular values. This procedure provides the means for more objective regularization and further dimensionality reduction of the problem. We apply this methodology to a moderate size, non-linear seismic tomography problem to image the structure of the crust and the upper mantle beneath Japan using local deep earthquakes recorded by the High Sensitivity Seismograph Network stations.
Xu, Qin; Cai, Lijuan; Zhao, Huijie; Tang, Jiaqian; Shen, Yuanyuan; Hu, Xiaoya; Zeng, Haibo
2015-01-15
An enzymatic procedure based on a catalase biosensor for the detection of forchlorfenuron (CPPU) has been reported in this work. Catalase was immobilized on boron nitride (BN) sheets dispersed in chitosan by adsorption. The immobilized catalase exhibited direct electron transfer character and excellent electrocatalytic activity towards H2O2 reduction. After introducing CPPU into the H2O2 containing phosphate buffer solution, the catalase-catalyzed H2O2 reduction current decreased. By measuring the current decrease, CPPU can be determined in the range of 0.5-10.0 µM with the detection limit of 0.07 μM. The non-competitive inhibition behavior of CPPU towards catalase was verified by the Lineweaver-Burk plots. Long stability character has been ascribed to this biosensor. Possible use of this biosensor in flow systems is illustrated. The proposed biosensor has been successfully applied to CPPU determination in fruits samples with satisfactory results. Copyright © 2014 Elsevier B.V. All rights reserved.
Recent advancements in GRACE mascon regularization and uncertainty assessment
NASA Astrophysics Data System (ADS)
Loomis, B. D.; Luthcke, S. B.
2017-12-01
The latest release of the NASA Goddard Space Flight Center (GSFC) global time-variable gravity mascon product applies a new regularization strategy along with new methods for estimating noise and leakage uncertainties. The critical design component of mascon estimation is the construction of the applied regularization matrices, and different strategies exist between the different centers that produce mascon solutions. The new approach from GSFC directly applies the pre-fit Level 1B inter-satellite range-acceleration residuals in the design of time-dependent regularization matrices, which are recomputed at each step of our iterative solution method. We summarize this new approach, demonstrating the simultaneous increase in recovered time-variable gravity signal and reduction in the post-fit inter-satellite residual magnitudes, until solution convergence occurs. We also present our new approach for estimating mascon noise uncertainties, which are calibrated to the post-fit inter-satellite residuals. Lastly, we present a new technique for end users to quickly estimate the signal leakage errors for any selected grouping of mascons, and we test the viability of this leakage assessment procedure on the mascon solutions produced by other processing centers.
Labeling Biomolecules with Radiorhenium - a Review of the Bifunctional Chelators
Liu, Guozheng; Hnatowich, Donald J.
2007-01-01
For radiotherapy, biomolecules such as intact antibodies, antibody fragments, peptides, DNAs and other oligomers have all been labeled with radiorhenium (186Re and 188Re). Three different approaches have been employed that may be referred to as direct, indirect and integral labeling. Direct labeling applies to proteins and involves the initial reduction of endogenous disulfide bridges to provide chelation sites. Indirect labeling can apply to most biomolecules and involves the initial attachment of an exogenous chelator. Finally, integral labeling is a special case applying only to small molecules in which the metallic radionuclide serves to link two parts of a biomolecule together in forming the labeled complex. While the number of varieties for the direct and integral radiolabeling approaches is rather limited, a fairly large and diverse number of chelators have been reported in the case of indirect labeling. Our objective herein is to provide an overview of the various chelators that have been used in the indirect labeling of biomolecules with radiorhenium, including details on the labeling procedures, the stability of the radiolabel and, where possible, the influence of the label on biological properties. PMID:17504162
Queue position in the endoscopic schedule impacts effectiveness of colonoscopy.
Lee, Alexander; Iskander, John M; Gupta, Nitin; Borg, Brian B; Zuckerman, Gary; Banerjee, Bhaskar; Gyawali, C Prakash
2011-08-01
Endoscopist fatigue potentially impacts colonoscopy. Fatigue is difficult to quantitate, but polyp detection rates between non-fatigued and fatigued time periods could represent a surrogate marker. We assessed whether timing variables impacted polyp detection rates at a busy tertiary care endoscopy suite. Consecutive patients undergoing colonoscopy were retrospectively identified. Indications, clinical demographics, pre-procedural, and procedural variables were extracted from chart review; colonoscopy findings were determined from the procedure reports. Three separate timing variables were assessed as surrogate markers for endoscopist fatigue: morning vs. afternoon procedures, start times throughout the day, and queue position, a unique variable that takes into account the number of procedures performed before the colonoscopy of interest. Univariate and multivariate analyses were performed to determine whether timing variables and other clinical, pre-procedural, and procedural variables predicted polyp detection. During the 4-month study period, 1,083 outpatient colonoscopy procedures (57.5±0.5 years, 59.5% female) were identified, performed by 28 endoscopists (mean 38.7 procedures/endoscopist), with a mean polyp detection rate of 0.851/colonoscopy. At least, one adenoma was detected in 297 procedures (27.4%). A 12.4% reduction in mean detected polyps was detected between morning and afternoon procedures (0.90±0.06 vs. 0.76±0.06, P=0.15). Using start time on a continuous scale, however, each elapsed hour in the day was associated with a 4.6% reduction in polyp detection (P=0.005). When queue position was assessed, a 5.4% reduction in polyp detection was noted with each increase in queue position (P=0.016). These results remained significant when controlled for each individual endoscopist. Polyp detection rates decline as time passes during an endoscopist's schedule, potentially from endoscopist fatigue. Queue position may be a novel surrogate measure for operator fatigue.
Prediction of chronic post-operative pain: pre-operative DNIC testing identifies patients at risk.
Yarnitsky, David; Crispel, Yonathan; Eisenberg, Elon; Granovsky, Yelena; Ben-Nun, Alon; Sprecher, Elliot; Best, Lael-Anson; Granot, Michal
2008-08-15
Surgical and medical procedures, mainly those associated with nerve injuries, may lead to chronic persistent pain. Currently, one cannot predict which patients undergoing such procedures are 'at risk' to develop chronic pain. We hypothesized that the endogenous analgesia system is key to determining the pattern of handling noxious events, and therefore testing diffuse noxious inhibitory control (DNIC) will predict susceptibility to develop chronic post-thoracotomy pain (CPTP). Pre-operative psychophysical tests, including DNIC assessment (pain reduction during exposure to another noxious stimulus at remote body area), were conducted in 62 patients, who were followed 29.0+/-16.9 weeks after thoracotomy. Logistic regression revealed that pre-operatively assessed DNIC efficiency and acute post-operative pain intensity were two independent predictors for CPTP. Efficient DNIC predicted lower risk of CPTP, with OR 0.52 (0.33-0.77 95% CI, p=0.0024), i.e., a 10-point numerical pain scale (NPS) reduction halves the chance to develop chronic pain. Higher acute pain intensity indicated OR of 1.80 (1.28-2.77, p=0.0024) predicting nearly a double chance to develop chronic pain for each 10-point increase. The other psychophysical measures, pain thresholds and supra-threshold pain magnitudes, did not predict CPTP. For prediction of acute post-operative pain intensity, DNIC efficiency was not found significant. Effectiveness of the endogenous analgesia system obtained at a pain-free state, therefore, seems to reflect the individual's ability to tackle noxious events, identifying patients 'at risk' to develop post-intervention chronic pain. Applying this diagnostic approach before procedures that might generate pain may allow individually tailored pain prevention and management, which may substantially reduce suffering.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 1 2011-04-01 2011-04-01 false What expedited procedures apply when FDA initiates... procedures apply when FDA initiates a seizure action against a detained perishable food? If FDA initiates a... under this subpart, FDA will send the seizure recommendation to the Department of Justice (DOJ) within 4...
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 1 2010-04-01 2010-04-01 false What expedited procedures apply when FDA initiates... procedures apply when FDA initiates a seizure action against a detained perishable food? If FDA initiates a... under this subpart, FDA will send the seizure recommendation to the Department of Justice (DOJ) within 4...
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 1 2012-04-01 2012-04-01 false What expedited procedures apply when FDA initiates... procedures apply when FDA initiates a seizure action against a detained perishable food? If FDA initiates a... under this subpart, FDA will send the seizure recommendation to the Department of Justice (DOJ) within 4...
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 1 2014-04-01 2014-04-01 false What expedited procedures apply when FDA initiates... procedures apply when FDA initiates a seizure action against a detained perishable food? If FDA initiates a... under this subpart, FDA will send the seizure recommendation to the Department of Justice (DOJ) within 4...
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 1 2013-04-01 2013-04-01 false What expedited procedures apply when FDA initiates... procedures apply when FDA initiates a seizure action against a detained perishable food? If FDA initiates a... under this subpart, FDA will send the seizure recommendation to the Department of Justice (DOJ) within 4...
Mattivi, Fulvio; Fedrizzi, Bruno; Zenato, Alberto; Tiefenthaler, Paolo; Tempesta, Silvano; Perenzoni, Daniele; Cantarella, Paolo; Simeoni, Federico; Vrhovsek, Urska
2012-06-30
This paper presents methods for the definition of important analytical tools, such as the development of sensitive and rapid methods for analysing reduced and oxidised glutathione (GSH and GSSG), hydroxycinnamic acids (HCA), bound thiols (GSH-3MH and Cys-3MH) and free thiols (3MH and 3MHA), and their first application to evaluate the effect of reductive winemaking on the composition of Lugana juices and wines. Lugana is a traditional white wine from the Lake Garda region (Italy), produced using a local grape variety, Trebbiano di Lugana. An innovative winemaking procedure based on preliminary cooling of grape berries followed by crushing in an inert environment was implemented and explored on a winery scale. The effects of these procedures on hydroxycinnamic acids, GSH, GSSG, free and bound thiols and flavanols content were investigated. The juices and wines produced using different protocols were examined. Moreover, wines aged in tanks for 1, 2 and 3 months were analysed. The high level of GSH found in Lugana grapes, which can act as a natural antioxidant and be preserved in must and young wines, thus reducing the need of exogenous antioxidants, was particularly interesting. Moreover, it was clear that polyphenol concentrations (hydroxycinnamic acids and catechins) were strongly influenced by winemaking and pressing conditions, which required fine tuning of pressing. Above-threshold levels of 3-mercaptohexan-1-ol (3MH) and 3-mercaptohexyl acetate (3MHA) were found in the wines and changed according to the winemaking procedure applied. Interestingly, the evolution during the first three months also varied depending on the procedure adopted. Organic synthesis of cysteine and glutathione conjugates was carried out and juices and wines were subjected to LC-MS/MS analysis. These two molecules appeared to be strongly affected by the winemaking procedure, but did not show any significant change during the first 3 months of post-bottling ageing. This supports the theory, already proposed in the literature, that there are other synthetic pathways for free thiol formation. Copyright © 2011 Elsevier B.V. All rights reserved.
Bayesian model reduction and empirical Bayes for group (DCM) studies
Friston, Karl J.; Litvak, Vladimir; Oswal, Ashwini; Razi, Adeel; Stephan, Klaas E.; van Wijk, Bernadette C.M.; Ziegler, Gabriel; Zeidman, Peter
2016-01-01
This technical note describes some Bayesian procedures for the analysis of group studies that use nonlinear models at the first (within-subject) level – e.g., dynamic causal models – and linear models at subsequent (between-subject) levels. Its focus is on using Bayesian model reduction to finesse the inversion of multiple models of a single dataset or a single (hierarchical or empirical Bayes) model of multiple datasets. These applications of Bayesian model reduction allow one to consider parametric random effects and make inferences about group effects very efficiently (in a few seconds). We provide the relatively straightforward theoretical background to these procedures and illustrate their application using a worked example. This example uses a simulated mismatch negativity study of schizophrenia. We illustrate the robustness of Bayesian model reduction to violations of the (commonly used) Laplace assumption in dynamic causal modelling and show how its recursive application can facilitate both classical and Bayesian inference about group differences. Finally, we consider the application of these empirical Bayesian procedures to classification and prediction. PMID:26569570
DOE Office of Scientific and Technical Information (OSTI.GOV)
Larson, N.M.
1984-02-01
This report describes a computer code (ALEX) developed to assist in AnaLysis of EXperimental data at the Oak Ridge Electron Linear Accelerator (ORELA). Reduction of data from raw numbers (counts per channel) to physically meaningful quantities (such as cross sections) is in itself a complicated procedure; propagation of experimental uncertainties through that reduction procedure has in the past been viewed as even more difficult - if not impossible. The purpose of the code ALEX is to correctly propagate all experimental uncertainties through the entire reduction procedure, yielding the complete covariance matrix for the reduced data, while requiring little additional inputmore » from the eperimentalist beyond that which is required for the data reduction itself. This report describes ALEX in detail, with special attention given to the case of transmission measurements (the code itself is applicable, with few changes, to any type of data). Application to the natural iron measurements of D.C. Larson et al. is described in some detail.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-31
... new policy or procedure. Because suspension of funding can have significant effects on client service... year of the grant term only, and there would be no effect on the recipient's level of funding for the... Funding, and Debarment Procedures; Recompetition; Enforcement; Suspension Procedures AGENCY: Legal...
42 CFR 419.44 - Payment reductions for procedures.
Code of Federal Regulations, 2012 CFR
2012-10-01
... beneficiary copayment amounts if the procedure for which anesthesia is planned is discontinued after the induction of anesthesia or after the procedure is started; (2) One-half the full program and the beneficiary copayment amounts if the procedure for which anesthesia is planned is discontinued after the patient is...
42 CFR 419.44 - Payment reductions for procedures.
Code of Federal Regulations, 2014 CFR
2014-10-01
... beneficiary copayment amounts if the procedure for which anesthesia is planned is discontinued after the induction of anesthesia or after the procedure is started; (2) One-half the full program and the beneficiary copayment amounts if the procedure for which anesthesia is planned is discontinued after the patient is...
42 CFR 419.44 - Payment reductions for procedures.
Code of Federal Regulations, 2013 CFR
2013-10-01
... beneficiary copayment amounts if the procedure for which anesthesia is planned is discontinued after the induction of anesthesia or after the procedure is started; (2) One-half the full program and the beneficiary copayment amounts if the procedure for which anesthesia is planned is discontinued after the patient is...
1979-01-01
fro:n the reduction procedures described below were analyzed by GLC on a 6 ft x 4 mm glass column using 3% Silar -IOC, 3,% OV-1 or 3% OV-17 on 100-120...Computer) follow:ng. gas chromatographic separation of reaction products obtained’from the -reduction and derivatization procedures wi h a 3% Silar -10C
Yung, Emmanuel; Wong, Michael; Williams, Haddie; Mache, Kyle
2014-08-01
Randomized clinical trial. Objectives To compare the blood pressure (BP) and heart rate (HR) response of healthy volunteers to posteriorly directed (anterior-to-posterior [AP]) pressure applied to the cervical spine versus placebo. Manual therapists employ cervical spine AP mobilizations for various cervical-shoulder pain conditions. However, there is a paucity of literature describing the procedure, cardiovascular response, and safety profile. Thirty-nine (25 female) healthy participants (mean ± SD age, 24.7 ± 1.9 years) were randomly assigned to 1 of 2 groups. Group 1 received a placebo, consisting of light touch applied to the right C6 costal process. Group 2 received AP pressure at the same location. Blood pressure and HR were measured prior to, during, and after the application of AP pressure. One-way analysis of variance and paired-difference statistics were used for data analysis. There was no statistically significant difference between groups for mean systolic BP, mean diastolic BP, and mean HR (P >.05) for all time points. Within-group comparisons indicated statistically significant differences between baseline and post-AP pressure HR (-2.8 bpm; 95% confidence interval: -4.6, -1.1) and between baseline and post-AP pressure systolic BP (-2.4 mmHg; 95% confidence interval: -3.7, -1.0) in the AP group, and between baseline and postplacebo systolic BP (-2.6 mmHg; 95% confidence interval: -4.2, -1.0) in the placebo group. No participants reported any adverse reactions or side effects within 24 hours of testing. AP pressure caused a statistically significant physiologic response that resulted in a minor drop in HR (without causing asystole or vasodepression) after the procedure, whereas this cardiovascular change did not occur for those in the placebo group. Within both groups, there was a small but statistically significant reduction in systolic BP following the procedure.
Design and Implementation of Data Reduction Pipelines for the Keck Observatory Archive
NASA Astrophysics Data System (ADS)
Gelino, C. R.; Berriman, G. B.; Kong, M.; Laity, A. C.; Swain, M. A.; Campbell, R.; Goodrich, R. W.; Holt, J.; Lyke, J.; Mader, J. A.; Tran, H. D.; Barlow, T.
2015-09-01
The Keck Observatory Archive (KOA), a collaboration between the NASA Exoplanet Science Institute and the W. M. Keck Observatory, serves science and calibration data for all active and inactive instruments from the twin Keck Telescopes located near the summit of Mauna Kea, Hawaii. In addition to the raw data, we produce and provide quick look reduced data for four instruments (HIRES, LWS, NIRC2, and OSIRIS) so that KOA users can more easily assess the scientific content and the quality of the data, which can often be difficult with raw data. The reduced products derive from both publicly available data reduction packages (when available) and KOA-created reduction scripts. The automation of publicly available data reduction packages has the benefit of providing a good quality product without the additional time and expense of creating a new reduction package, and is easily applied to bulk processing needs. The downside is that the pipeline is not always able to create an ideal product, particularly for spectra, because the processing options for one type of target (eg., point sources) may not be appropriate for other types of targets (eg., extended galaxies and nebulae). In this poster we present the design and implementation for the current pipelines used at KOA and discuss our strategies for handling data for which the nature of the targets and the observers' scientific goals and data taking procedures are unknown. We also discuss our plans for implementing automated pipelines for the remaining six instruments.
Modeling and reduction with applications to semiconductor processing
NASA Astrophysics Data System (ADS)
Newman, Andrew Joseph
This thesis consists of several somewhat distinct but connected parts, with an underlying motivation in problems pertaining to control and optimization of semiconductor processing. The first part (Chapters 3 and 4) addresses problems in model reduction for nonlinear state-space control systems. In 1993, Scherpen generalized the balanced truncation method to the nonlinear setting. However, the Scherpen procedure is not easily computable and has not yet been applied in practice. We offer a method for computing a working approximation to the controllability energy function, one of the main objects involved in the method. Moreover, we show that for a class of second-order mechanical systems with dissipation, under certain conditions related to the dissipation, an exact formula for the controllability function can be derived. We then present an algorithm for a numerical implementation of the Morse-Palais lemma, which produces a local coordinate transformation under which a real-valued function with a non-degenerate critical point is quadratic on a neighborhood of the critical point. Application of the algorithm to the controllabilty function plays a key role in computing the balanced representation. We then apply our methods and algorithms to derive balanced realizations for nonlinear state-space models of two example mechanical systems: a simple pendulum and a double pendulum. The second part (Chapter 5) deals with modeling of rapid thermal chemical vapor deposition (RTCVD) for growth of silicon thin films, via first-principles and empirical analysis. We develop detailed process-equipment models and study the factors that influence deposition uniformity, such as temperature, pressure, and precursor gas flow rates, through analysis of experimental and simulation results. We demonstrate that temperature uniformity does not guarantee deposition thickness uniformity in a particular commercial RTCVD reactor of interest. In the third part (Chapter 6) we continue the modeling effort, specializing to a control system for RTCVD heat transfer. We then develop and apply ad-hoc versions of prominent model reduction approaches to derive reduced models and perform a comparative study.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 24 Housing and Urban Development 4 2010-04-01 2010-04-01 false What procedures apply to complaints arising out of any of the methods of providing for Indian preference? 1000.54 Section 1000.54 Housing and... ACTIVITIES General § 1000.54 What procedures apply to complaints arising out of any of the methods of...
Code of Federal Regulations, 2010 CFR
2010-04-01
... ADMINISTRATIVE PROVISIONS UNDER TITLE I OF THE WORKFORCE INVESTMENT ACT Grievance Procedures, Complaints, and State Appeals Processes § 667.650 What procedures apply to the appeals of the Governor's imposition of...
20 CFR 667.645 - What procedures apply to the appeals of non-designation of local areas?
Code of Federal Regulations, 2010 CFR
2010-04-01
..., DEPARTMENT OF LABOR ADMINISTRATIVE PROVISIONS UNDER TITLE I OF THE WORKFORCE INVESTMENT ACT Grievance Procedures, Complaints, and State Appeals Processes § 667.645 What procedures apply to the appeals of non... must establish that it was not accorded procedural rights under the appeal process set forth in the...
NASA Astrophysics Data System (ADS)
Gebhardt, Pierre; Wehner, Jakob; Weissler, Bjoern; Frach, Thomas; Marsden, Paul K.; Schulz, Volkmar
2015-06-01
Devices aiming at combined Positron Emission Tomography (PET) and Magnetic Resonance Imaging (MRI) to enable simultaneous PET/MR image acquisition have to fulfill demanding requirements to avoid mutual magneticas well as electromagnetic-field-related interferences which lead to image quality degradation. Particularly Radio-Frequency (RF)-field-related interferences between PET and MRI may lead to MRI SNR reduction, thereby deteriorating MR image quality. RF shielding of PET electronics is therefore commonly applied to reduce RF emission and lower the potential coupling into MRI RF coil(s). However, shields introduce eddy-current-induced MRI field distortions and should thus be minimized or ideally omitted. Although the MRI noise floor increase caused by a PET system might be acceptable for many MRI applications, some MRI protocols, such as fast or high-resolution MRI scans, typically suffer from low SNR and might need more attention regarding RF silence to preserve the intrinsic MRI SNR. For such cases, we propose RESCUE, an MRI-synchronously-gated PET data acquisition technique: By interrupting the PET acquisition during MR signal receive phases, PET-related RF emission may be minimized, leading to MRI SNR preservation. Our PET insert Hyperion IID using Philips Digital Photon Counting (DPC) sensors serves as the platform to demonstrate RESCUE. To make the DPC sensor suitable for RESCUE to be applied for many MRI sequences with acquisition time windows in the range of a few milliseconds, we present in this paper a new technique which enables rapid DPC sensor operation interruption by dramatically lowering the overhead time to interrupt and restart the sensor operation. Procedures to enter and leave gated PET data acquisition may imply sensitivity losses which add to the ones occurring during MRI RF acquisition. For the case of our PET insert, the new DPC quick-interruption technique yields a PET sensitivity loss reduction by a factor of 78 when compared to the loss introduced with the standard start/stop procedure. For instance, PET sensitivity losses related to overhead time are 2.9% in addition to the loss related to PET gating being equal to the MRI RF acquisition duty cycle (14.7%) for an exemplary T1-weighted 3D-FFE MRI sequence. MRI SNR measurement results obtained with one Singles Detection Module (SDM) using no RF shield demonstrate a noise floor reduction by a factor of 2.1, getting close to the noise floor level of the SNR reference scan (SDM off-powered) when RESCUE was active.
An alternative to Guyan reduction of finite-element models
NASA Technical Reports Server (NTRS)
Lin, Jiguan Gene
1988-01-01
Structural modeling is a key part of structural system identification for large space structures. Finite-element structural models are commonly used in practice because of their general applicability and availability. The initial models generated by using a standard computer program such as NASTRAN, ANSYS, SUPERB, STARDYNE, STRUDL, etc., generally contain tens of thousands of degrees of freedom. The models must be reduced for purposes of identification. Not only does the magnitude of the identification effort grow exponentially as a function of the number of degrees of freedom, but numerical procedures may also break down because of accumulated round-off errors. Guyan reduction is usually applied after a static condensation. Misapplication of Guyan reduction can lead to serious modeling errors. It is quite unfortunate and disappointing, since the accuracy of the original detailed finite-element model one tries very hard to achieve is lost by the reduction. First, why and how Guyan reduction always causes loss of accuracy is examined. An alternative approach is then introduced. The alternative can be thought of as an improvement of Guyan reduction, the Rayleigh-Ritz method, and in particular the recent algorithm of Wilson, Yuan, and Dickens. Unlike Guyan reduction, the use of the alternative does not need any special insight, experience, or skill for partitioning the structural degrees of freedom. In addition to model condensation, this alternative approach can also be used for predicting analytically, quickly, and economically, what are those structural modes that are excitable by a force actuator at a given trial location. That is, in the excitation of the structural modes for identification, it can be used for guiding the placement of the force actuators.
Spillover effects of Medicare fee reductions: evidence from ophthalmology.
Mitchell, Jean M; Hadley, Jack; Gaskin, Darrell J
2002-09-01
Relatively little research has examined physicians' supply responses to Medicare fee cuts especially whether fee reductions for specific procedures have "spillover" effects that cause physicians to increase the supply of other services they provide. In this study we investigate whether ophthalmologist changed their provision of non-cataract services to Medicare patients over the time period 1992-1994, when the Medicare Fee Schedule (MFS) resulted in a 17.4% reduction in the average fee paid for a cataract extraction. Following the McGuire-Pauly model of physician behavior (McGuire and Pauly, 1991), we estimated a supply function for non-cataract procedures that included three price variables (own-price, a Medicare cross-price and a private cross-price) and an income effect. The Medicare cross-price and income variables capture spillover effects. Consistent with the model's predictions, we found that the Medicare cross-price is significant and negative, implying that a 10% reduction in the fee for a cataract extraction will cause ophthalmologists to supply about 5% more non-cataract services. Second, the income variable is highly significant, but its impact on the supply of non-cataract services is trivial. The suggests that physicians behave more like profit maximizing firms than target income seekers. We also found that the own-price and the private cross-price variables are highly significant and have the expected positive and negative effects on the volume of non-cataract services respectively. Our results demonstrate the importance of evaluating volume responses to fee changes for the array of services the physician performs, not just the procedure whose fee has been reduced. Focusing only on the procedure whose fee has been cut will yield an incomplete picture of how fee reductions for specific procedures affect physician supply decisions.
Day, Theodore Eugene; Sarawgi, Sandeep; Perri, Alexis; Nicolson, Susan C
2015-04-01
This study describes the use of discrete event simulation (DES) to model and analyze a large academic pediatric and test cardiac center. The objective was to identify a strategy, and to predict and test the effectiveness of that strategy, to minimize the number of elective cardiac procedures that are postponed because of a lack of available cardiac intensive care unit (CICU) capacity. A DES of the cardiac center at The Children's Hospital of Philadelphia was developed and was validated by use of 1 year of deidentified administrative patient data. The model was then used to analyze strategies for reducing postponements of cases requiring CICU care through improved scheduling of multipurpose space. Each of five alternative scenarios was simulated for ten independent 1-year runs. Reductions in simulated elective procedure postponements were found when a multipurpose procedure room (the hybrid room) was used for operations on Wednesday and Thursday, compared with Friday (as was the real-world use). The reduction Wednesday was statistically significant, with postponements dropping from 27.8 to 23.3 annually (95% confidence interval 18.8-27.8). Thus, we anticipate a relative reduction in postponements of 16.2%. Since the implementation, there have been two postponements from July 1 to November 21, 2014, compared with ten for the same time period in 2013. Simulation allows us to test planned changes in complex environments, including pediatric cardiac care. Reduction in postponements of cardiac procedures requiring CICU care is predicted through reshuffling schedules of existing multipurpose capacity, and these reductions appear to be achievable in the real world after implementation. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Yeste, Marc; Codony, Francesc; Estrada, Efrén; Lleonart, Miquel; Balasch, Sam; Peña, Alejandro; Bonet, Sergi; Rodríguez-Gil, Joan E.
2016-01-01
The present study evaluated the effects of exposing liquid-stored boar semen to different red light LED regimens on sperm quality and reproductive performance. Of all of the tested photo-stimulation procedures, the best pattern consisted of 10 min light, 10 min rest and 10 min of further light (10-10-10 pattern). This pattern induced an intense and transient increase in the majority of motility parameters, without modifying sperm viability and acrosome integrity. While incubating non-photo-stimulated sperm at 37 °C for 90 min decreased all sperm quality parameters, this reduction was prevented when the previously-described light procedure was applied. This effect was concomitant with an increase in the percentage of sperm with high mitochondrial membrane potential. When sperm were subjected to ‘in vitro’ capacitation, photo-stimulation also increased the percentage of sperm with capacitation-like changes in membrane structure. On the other hand, treating commercial semen doses intended for artificial insemination with the 10-10-10 photo-stimulation pattern significantly increased farrowing rates and the number of both total and live-born piglets for parturition. Therefore, our results indicate that a precise photo-stimulation procedure is able to increase the fertilising ability of boar sperm via a mechanism that could be related to mitochondrial function. PMID:26931070
Ortenzi, Monica; Ghiselli, Roberto; Baldarelli, Maddalena; Cardinali, Luca; Guerrieri, Mario
2018-04-01
The latest robotic bipolar vessel sealing tools have been described to be effective allowing to perform procedures with reduced blood loss and shorter operative times. The aim of this study was to assess the efficacy and reliability of these devices applied in different robotic procedures. All robotic operations, between 2014 and 2016, were performed using the EndoWrist One VesselSealer (EWO, Intuitive Surgical, Sunnyvale, CA), a bipolar fully wristed device. Data, including age, gender, body mass index (BMI), were collected. Robot docking time, intraoperative blood loss, robot malfunctioning and overall operative time were analyzed. A meta-analysis of the literature was carried out to point the attention to three different parameters (mean blood loss, operating time and hospital stay) trying to identify how different coagulation devices may affect them. In 73 robotic procedures, the mean operative time was 118.2 minutes (75-125 minutes). Mean hospital stay was four days (2-10 days). There were two post-operative complications (2.74%). The bipolar vessel sealer offers the efficacy of bipolar diathermy and the advantages of a fully wristed instrument. It does not require any change of instruments for coagulation or involvement of the bedside assistant surgeon. These characteristics lead to a reduction in operative time.
Model-size reduction for the buckling and vibration analyses of anisotropic panels
NASA Technical Reports Server (NTRS)
Noor, A. K.; Whitworth, S. L.
1986-01-01
A computational procedure is presented for reducing the size of the model used in the buckling and vibration analyses of symmetric anisotropic panels to that of the corresponding orthotropic model. The key elements of the procedure are the application of an operator splitting technique through the decomposition of the material stiffness matrix of the panel into the sum of orthotropic and nonorthotropic (anisotropic) parts and the use of a reduction method through successive application of the finite element method and the classical Rayleigh-Ritz technique. The effectiveness of the procedure is demonstrated by numerical examples.
Performance factors in associative learning: assessment of the sometimes competing retrieval model.
Witnauer, James E; Wojick, Brittany M; Polack, Cody W; Miller, Ralph R
2012-09-01
Previous simulations revealed that the sometimes competing retrieval model (SOCR; Stout & Miller, Psychological Review, 114, 759-783, 2007), which assumes local error reduction, can explain many cue interaction phenomena that elude traditional associative theories based on total error reduction. Here, we applied SOCR to a new set of Pavlovian phenomena. Simulations used a single set of fixed parameters to simulate each basic effect (e.g., blocking) and, for specific experiments using different procedures, used fitted parameters discovered through hill climbing. In simulation 1, SOCR was successfully applied to basic acquisition, including the overtraining effect, which is context dependent. In simulation 2, we applied SOCR to basic extinction and renewal. SOCR anticipated these effects with both fixed parameters and best-fitting parameters, although the renewal effects were weaker than those observed in some experiments. In simulation 3a, feature-negative training was simulated, including the often observed transition from second-order conditioning to conditioned inhibition. In simulation 3b, SOCR predicted the observation that conditioned inhibition after feature-negative and differential conditioning depends on intertrial interval. In simulation 3c, SOCR successfully predicted failure of conditioned inhibition to extinguish with presentations of the inhibitor alone under most circumstances. In simulation 4, cue competition, including blocking (4a), recovery from relative validity (4b), and unblocking (4c), was simulated. In simulation 5, SOCR correctly predicted that inhibitors gain more behavioral control than do excitors when they are trained in compound. Simulation 6 demonstrated that SOCR explains the slower acquisition observed following CS-weak shock pairings.
How to Compress Sequential Memory Patterns into Periodic Oscillations: General Reduction Rules
Zhang, Kechen
2017-01-01
A neural network with symmetric reciprocal connections always admits a Lyapunov function, whose minima correspond to the memory states stored in the network. Networks with suitable asymmetric connections can store and retrieve a sequence of memory patterns, but the dynamics of these networks cannot be characterized as readily as that of the symmetric networks due to the lack of established general methods. Here, a reduction method is developed for a class of asymmetric attractor networks that store sequences of activity patterns as associative memories, as in a Hopfield network. The method projects the original activity pattern of the network to a low-dimensional space such that sequential memory retrievals in the original network correspond to periodic oscillations in the reduced system. The reduced system is self-contained and provides quantitative information about the stability and speed of sequential memory retrievals in the original network. The time evolution of the overlaps between the network state and the stored memory patterns can also be determined from extended reduced systems. The reduction procedure can be summarized by a few reduction rules, which are applied to several network models, including coupled networks and networks with time-delayed connections, and the analytical solutions of the reduced systems are confirmed by numerical simulations of the original networks. Finally, a local learning rule that provides an approximation to the connection weights involving the pseudoinverse is also presented. PMID:24877729
NASA Astrophysics Data System (ADS)
Zhao, Yang; Chang, Wenkai; Huang, Zhiding; Feng, Xugen; Ma, Lin; Qi, Xiaoxia; Li, Zenghe
2017-05-01
Owing to the acute toxicity and mobility, the Cr(VI) in tannery wastewater is a huge threat to biological and environmental systems. Herein, an effective photoelectrocatalytic reduction of Cr(VI) was carried out by applying electric field to photocatalysis of as-prepared TiO2 spheres. The synthesis of spherical TiO2 catalytic materials with hollow structure and high surface areas was based on a self-assembly process induced by a mixture of organic acetic acid and ethanol. The possible formation mechanism of TiO2 spheres was proposed and verified by acid concentration-dependent and temperature-dependent experiments. It was found that the reaction rate constant of photoelectrocatalytic reduction of Cr(VI) exhibited an almost 3 fold improvement (0.0362 min-1) as compared to that of photocatalysis (0.0126 min-1). As a result, the mechanism of photoelectrocatalytic reduction of Cr(VI) was described according to the simultaneous determination of Cr(VI), Cr(III) and total Cr in the system. In addition, the effect of pH value and voltage of potential were also discussed. Moreover, this photoelectrocatalysis with TiO2 hollow spheres exhibited excellent activity for reduction of Cr(VI) in actual tannery wastewater produced from three different tanning procedures. These attributes suggest that this photoelectrocatalysis has strong potential applications in the treatment of tannery pollutants.
Reitsma, Welmoed; Mourits, Marian J E; Koning, Merel; Pascal, Astrid; van der Lei, Berend
2011-08-01
Physicians are increasingly presented with women requesting a labia minora reduction procedure. To assess the influencing factor of personal predisposition in general practitioners, gynecologists, and plastic surgeons to labia minora appearance in relation to their willingness to refer for, or perform, a surgical labia minora reduction. Cross-sectional self-administered questionnaire survey. Between May 2009 and August 2009, 210 physicians were surveyed. Primary care: general practitioners working in the north of the Netherlands. Secondary care: gynecologists and plastic surgeons working in five hospitals in the north of the Netherlands. A five-point Likert scale appraisal of four pictures showing a vulva, each displaying different sizes of labia minora, indicating a physician's personal predisposition, manifesting as willingness to refer for, or perform, a labia minora reduction. A total of 164/210 (78.1%) physicians completed the questionnaire, consisting of 80 general practitioners, 41 gynecologists, and 43 plastic surgeons (96 males, 68 females). Ninety percent of all physicians believe, to a certain extent, that a vulva with very small labia minora represents society's ideal (2-5 on the Likert scale). More plastic surgeons regarded the picture with the largest labia minora as distasteful and unnatural, compared with general practitioners and gynecologists (P < 0.01), and regarded such a woman as a candidate for a labia minora reduction procedure (P < 0.001). Irrespective of the woman's labia minora size and the absence of physical complaints, plastic surgeons were significantly more open to performing a labia minora reduction procedure than gynecologists (P < 0.001). Male physicians were more inclined to opt for a surgical reduction procedure than their female colleagues (P < 0.01). The personal predisposition of physicians (taking account of their specific gender and specialty) concerning labia minora size and appearance influences their clinical decision making regarding a labia minora reduction procedure. Heightened awareness of one's personal predisposition vis-à-vis referral and willingness to operate is needed. © 2011 International Society for Sexual Medicine.
Reduction and reconstruction of the dynamics of nonholonomic systems
NASA Astrophysics Data System (ADS)
Cortés, Jorge; de León, Manuel
1999-12-01
The reduction and reconstruction of the dynamics of nonholonomic mechanical systems with symmetry are investigated. We have considered a more general framework of constrained Hamiltonian systems since they appear in the reduction procedure. A reduction scheme in terms of the nonholonomic momentum mapping is developed. The reduction of the nonholonomic brackets is also discussed. The theory is illustrated with several examples.
Parallel Nonnegative Least Squares Solvers for Model Order Reduction
2016-03-01
NNLS problems that arise when the Energy Conserving Sampling and Weighting hyper -reduction procedure is used when constructing a reduced-order model...ScaLAPACK and performance results are presented. nonnegative least squares, model order reduction, hyper -reduction, Energy Conserving Sampling and...optimal solution. ........................................ 20 Table 6 Reduced mesh sizes produced for each solver in the ECSW hyper -reduction step
42 CFR 419.44 - Payment reductions for procedures.
Code of Federal Regulations, 2011 CFR
2011-10-01
... amounts if the procedure for which anesthesia is planned is discontinued after the induction of anesthesia... amounts if the procedure for which anesthesia is planned is discontinued after the patient is prepared and taken to the room where the procedure is to be performed but before anesthesia is induced; or (3) One...
42 CFR 419.44 - Payment reductions for procedures.
Code of Federal Regulations, 2010 CFR
2010-10-01
... amounts if the procedure for which anesthesia is planned is discontinued after the induction of anesthesia... amounts if the procedure for which anesthesia is planned is discontinued after the patient is prepared and taken to the room where the procedure is to be performed but before anesthesia is induced; or (3) One...
ERIC Educational Resources Information Center
Rose, Homer C., Jr.; Hample, Stephen R.
1982-01-01
Considerations that can help colleges and universities develop institutionally specific strategies for planning faculty reductions are addressed. It is suggested that an institution can provide a fair and workable reduction plan if it: thoroughly explores alternatives to faculty layoffs; develops explicit standards and procedures for reduction…
Impact of Medicare payment reductions on access to surgical services.
Mitchell, J B; Cromwell, J
1995-01-01
OBJECTIVE. This study evaluates the impact of surgical fee reductions under Medicare on the utilization of surgical services. DATA SOURCES. Medicare physician claims data were obtained from 11 states for a five-year time period (1985-1989). STUDY DESIGN. Under OBRA-87, Medicare reduced payments for 11 surgical procedures. A fixed effects regression method was used to determine the impact of these payment reductions on access to care for potentially vulnerable Medicare beneficiaries: joint Medicaid-eligibles, blacks, and the very old. DATA COLLECTION/EXTRACTION METHODS. Medicare claims and enrollment data were used to construct a cross-section time-series of population-based surgical rates from 1985 through 1989. PRINCIPAL FINDINGS. Reductions in surgical fees led to small but significant increases in use for three procedures, small decreases in use for two procedures, and no impact on the remaining six procedures. There was little evidence that access to surgery was impaired for potentially vulnerable enrollees; in fact, declining fees often led to greater rates of increases for some subgroups. CONCLUSIONS. Our results suggest that volume responses by surgeons to payment changes under the Medicare Fee Schedule may be smaller than HCFA's original estimates. Nevertheless, both access and quality of care should continue to be closely monitored. PMID:8537224
Ghodsi, Seyed Hamed; Kerachian, Reza; Zahmatkesh, Zahra
2016-04-15
In this paper, an integrated framework is proposed for urban runoff management. To control and improve runoff quality and quantity, Low Impact Development (LID) practices are utilized. In order to determine the LIDs' areas and locations, the Non-dominated Sorting Genetic Algorithm-II (NSGA-II), which considers three objective functions of minimizing runoff volume, runoff pollution and implementation cost of LIDs, is utilized. In this framework, the Storm Water Management Model (SWMM) is used for stream flow simulation. The non-dominated solutions provided by the NSGA-II are considered as management scenarios. To select the most preferred scenario, interactions among the main stakeholders in the study area with conflicting utilities are incorporated by utilizing bargaining models including a non-cooperative game, Nash model and social choice procedures of Borda count and approval voting. Moreover, a new social choice procedure, named pairwise voting method, is proposed and applied. Based on each conflict resolution approach, a scenario is identified as the ideal solution providing the LIDs' areas, locations and implementation cost. The proposed framework is applied for urban water quality and quantity management in the northern part of Tehran metropolitan city, Iran. Results show that the proposed pairwise voting method tends to select a scenario with a higher percentage of reduction in TSS (Total Suspended Solid) load and runoff volume, in comparison with the Borda count and approval voting methods. Besides, the Nash method presents a management scenario with the highest cost for LIDs' implementation and the maximum values for percentage of runoff volume reduction and TSS removal. The results also signify that selection of an appropriate management scenario by stakeholders in the study area depends on the available financial resources and the relative importance of runoff quality improvement in comparison with reducing the runoff volume. Copyright © 2016 Elsevier B.V. All rights reserved.
A spin column-free approach to sodium hydroxide-based glycan permethylation.
Hu, Yueming; Borges, Chad R
2017-07-24
Glycan permethylation was introduced as a tool to facilitate the study of glycans in 1903. Since that time, permethylation procedures have been continually modified to improve permethylation efficiency and qualitative applicability. Typically, however, either laborious preparation steps or cumbersome and uneconomical spin columns have been needed to obtain decent permethylation yields on small glycan samples. Here we describe a spin column-free (SCF) glycan permethylation procedure that is applicable to both O- and N-linked glycans and can be employed upstream to intact glycan analysis by MALDI-MS, ESI-MS, or glycan linkage analysis by GC-MS. The SCF procedure involves neutralization of NaOH beads by acidified phosphate buffer, which eliminates the risk of glycan oxidative degradation and avoids the use of spin columns. Optimization of the new permethylation procedure provided high permethylation efficiency for both hexose (>98%) and HexNAc (>99%) residues-yields which were comparable to (or better than) those of some widely-used spin column-based procedures. A light vs. heavy labelling approach was employed to compare intact glycan yields from a popular spin-column based approach to the SCF approach. Recovery of intact N-glycans was significantly better with the SCF procedure (p < 0.05), but overall yield of O-glycans was similar or slightly diminished (p < 0.05 for tetrasaccharides or smaller). When the SCF procedure was employed upstream to hydrolysis, reduction and acetylation for glycan linkage analysis of pooled glycans from unfractionated blood plasma, analytical reproducibility was on par with that from previous spin column-based "glycan node" analysis results. When applied to blood plasma samples from stage III-IV breast cancer patients (n = 20) and age-matched controls (n = 20), the SCF procedure facilitated identification of three glycan nodes with significantly different distributions between the cases and controls (ROC c-statistics > 0.75; p < 0.01). In summary, the SCF permethylation procedure expedites and economizes both intact glycan analysis and linkage analysis of glycans from whole biospecimens.
A spin column-free approach to sodium hydroxide-based glycan permethylation†
Hu, Yueming; Borges, Chad R.
2018-01-01
Glycan permethylation was introduced as a tool to facilitate the study of glycans in 1903. Since that time, permethylation procedures have been continually modified to improve permethylation efficiency and qualitative applicability. Typically, however, either laborious preparation steps or cumbersome and uneconomical spin columns have been needed to obtain decent permethylation yields on small glycan samples. Here we describe a spin column-free (SCF) glycan permethylation procedure that is applicable to both O- and N-linked glycans and can be employed upstream to intact glycan analysis by MALDI-MS, ESI-MS, or glycan linkage analysis by GC-MS. The SCF procedure involves neutralization of NaOH beads by acidified phosphate buffer, which eliminates the risk of glycan oxidative degradation and avoids the use of spin columns. Optimization of the new permethylation procedure provided high permethylation efficiency for both hexose (>98%) and HexNAc (>99%) residues—yields which were comparable to (or better than) those of some widely-used spin column-based procedures. A light vs. heavy labelling approach was employed to compare intact glycan yields from a popular spin-column based approach to the SCF approach. Recovery of intact N-glycans was significantly better with the SCF procedure (p < 0.05), but overall yield of O-glycans was similar or slightly diminished (p < 0.05 for tetrasaccharides or smaller). When the SCF procedure was employed upstream to hydrolysis, reduction and acetylation for glycan linkage analysis of pooled glycans from unfractionated blood plasma, analytical reproducibility was on par with that from previous spin column-based “glycan node” analysis results. When applied to blood plasma samples from stage III–IV breast cancer patients (n = 20) and age-matched controls (n = 20), the SCF procedure facilitated identification of three glycan nodes with significantly different distributions between the cases and controls (ROC c-statistics > 0.75; p < 0.01). In summary, the SCF permethylation procedure expedites and economizes both intact glycan analysis and linkage analysis of glycans from whole biospecimens. PMID:28635997
Landucci, A; Wosny, A C; Uetanabaro, L C; Moro, A; Araujo, M R
2016-03-01
The clinical efficacy of low-level laser therapy (LLLT) for the reduction of pain, swelling, and trismus following the surgical extraction of third molars was evaluated. Mandibular third molars, with similar radiographic positions on two distinct sections, were extracted from 22 patients. Immediately after extraction from the randomly selected right or left side, LLLT was applied (study group). The same extraction procedure was performed 21 days later on the other third molar, without the application of LLLT (control group). LLLT was applied at 10 points: four intraoral in close proximity to the socket and six extraoral along the masseter muscle. Pain intensity was assessed using a visual analogue scale, swelling was measured as the distance from the tragus to the median base of the mentum, and trismus was assessed by the extent of mouth opening. Data were collected at four time points: before surgery, immediately after surgery, 48h postoperatively, and 7 days postoperatively. Compared with the control group, the study group showed significant reductions in pain, swelling, and trismus at 48h and 7 days postoperatively. In conclusion, a single dose of LLLT was effective at reducing the postoperative discomforts (pain, swelling, and trismus) associated with third molar extraction surgery. Copyright © 2015 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
20 CFR 229.66 - Changes in reduction amount.
Code of Federal Regulations, 2010 CFR
2010-04-01
.... The amount of the worker's compensation or public disability benefit reduction does not change when... composition had existed when the worker's compensation or public disability benefit reduction first applied...'s compensation or public disability benefit and average current earnings are the same as those used...
Zhang, Hui; Lu, Naiji; Feng, Changyong; Thurston, Sally W.; Xia, Yinglin; Tu, Xin M.
2011-01-01
Summary The generalized linear mixed-effects model (GLMM) is a popular paradigm to extend models for cross-sectional data to a longitudinal setting. When applied to modeling binary responses, different software packages and even different procedures within a package may give quite different results. In this report, we describe the statistical approaches that underlie these different procedures and discuss their strengths and weaknesses when applied to fit correlated binary responses. We then illustrate these considerations by applying these procedures implemented in some popular software packages to simulated and real study data. Our simulation results indicate a lack of reliability for most of the procedures considered, which carries significant implications for applying such popular software packages in practice. PMID:21671252
Digant, Shastri Mona; Rucha, Seth; Eke, Dessai
2012-12-01
The conventional hydrostatic reduction of an intussusception with barium enema or the pneumatic reduction of an intussusception is associated with considerable ionizing radiations and a risk of perforation; while the hydrostatic reduction of an intussusception under ultrasound guidance is a very safe method because the whole procedure is visualized with real time ultrasound. Also, being a non-invasive method with a high success rate, this procedure has emerged as a useful alternative to a surgical intervention. The aim of this study was to evaluate the role of ultrasound and colour Doppler studies for the guidance of the hydrostatic reduction of a childhood intussusception by using normal saline. Among 41 children who were evaluated with ultrasonography for the confirmation of the presence of intussusceptions, hydrostatic reduction of intussusception were performed under a sonographic guidance in 30 patients, whereas 11 patients were excluded due to clinical contraindications. This disease was observed mostly at the ages of 6 months to 24 months. In 80% of the patients, there was a recent history of gastroenteritis and 40 % had a history of common cold. The most common site of the intussusception was the transverse colon near the hepatic flexor of the colon (90%), with a mean duration of 22.1±17.3 hours. The overall rate of a successful reduction was 87% and the mean reduction time was 14 minutes. None of the cases showed recurrence within 24 hrs. No complications were observed. We conclude that ultrasound with colour Doppler study is very useful for the diagnosis of intussusceptions, as well as for guided hydrostatic reductions by using normal saline enema. This is an optimal, simple, and a safe procedure for the treatment of intussusceptions in paediatric patients.
NASA Technical Reports Server (NTRS)
Ford, G. E. (Principal Investigator)
1984-01-01
Principal components transformations was applied to a Walnut Creek, Texas subscene to reduce the dimensionality of the multispectral sensor data. This transformation was also applied to a LANDSAT 3 MSS subscene of the same area acquired in a different season and year. Results of both procedures are tabulated and allow for comparisons between TM and MSS data. The TM correlation matrix shows that visible bands 1 to 3 exhibit a high degree of correlation in the range 0.92 to 0.96. Correlation for bands 5 to 7 is 0.93. Band 4 is not highly correlated with any other band, with corrections in the range 0.13 to 0.52. The thermal band (6) is not highly correlated with other bands in the range 0.13 to 0.46. The MSS correlation matrix shows that bands 4 and 5 are highly correlated (0.96) as are bands 6 and 7 with a correlation of 0.92.
A new technique for solving puzzles.
Makridis, Michael; Papamarkos, Nikos
2010-06-01
This paper proposes a new technique for solving jigsaw puzzles. The novelty of the proposed technique is that it provides an automatic jigsaw puzzle solution without any initial restriction about the shape of pieces, the number of neighbor pieces, etc. The proposed technique uses both curve- and color-matching similarity features. A recurrent procedure is applied, which compares and merges puzzle pieces in pairs, until the original puzzle image is reformed. Geometrical and color features are extracted on the characteristic points (CPs) of the puzzle pieces. CPs, which can be considered as high curvature points, are detected by a rotationally invariant corner detection algorithm. The features which are associated with color are provided by applying a color reduction technique using the Kohonen self-organized feature map. Finally, a postprocessing stage checks and corrects the relative position between puzzle pieces to improve the quality of the resulting image. Experimental results prove the efficiency of the proposed technique, which can be further extended to deal with even more complex jigsaw puzzle problems.
NASA Technical Reports Server (NTRS)
Hague, D. S.; Merz, A. W.
1975-01-01
Multivariable search techniques are applied to a particular class of airfoil optimization problems. These are the maximization of lift and the minimization of disturbance pressure magnitude in an inviscid nonlinear flow field. A variety of multivariable search techniques contained in an existing nonlinear optimization code, AESOP, are applied to this design problem. These techniques include elementary single parameter perturbation methods, organized search such as steepest-descent, quadratic, and Davidon methods, randomized procedures, and a generalized search acceleration technique. Airfoil design variables are seven in number and define perturbations to the profile of an existing NACA airfoil. The relative efficiency of the techniques are compared. It is shown that elementary one parameter at a time and random techniques compare favorably with organized searches in the class of problems considered. It is also shown that significant reductions in disturbance pressure magnitude can be made while retaining reasonable lift coefficient values at low free stream Mach numbers.
NASA Astrophysics Data System (ADS)
Bechara, William S.; Pelletier, Guillaume; Charette, André B.
2012-03-01
The development of efficient and selective transformations is crucial in synthetic chemistry as it opens new possibilities in the total synthesis of complex molecules. Applying such reactions to the synthesis of ketones is of great importance, as this motif serves as a synthetic handle for the elaboration of numerous organic functionalities. In this context, we report a general and chemoselective method based on an activation/addition sequence on secondary amides allowing the controlled isolation of structurally diverse ketones and ketimines. The generation of a highly electrophilic imidoyl triflate intermediate was found to be pivotal in the observed exceptional functional group tolerance, allowing the facile addition of readily available Grignard and diorganozinc reagents to amides, and avoiding commonly observed over-addition or reduction side reactions. The methodology has been applied to the formal synthesis of analogues of the antineoplastic agent Bexarotene and to the rapid and efficient synthesis of unsymmetrical diketones in a one-pot procedure.
Skin rejuvenating effects of chemical peeling: a study in photoaged hairless mice.
Han, Sung Hyup; Kim, Hong Jig; Kim, Si Yong; Kim, You Chan; Choi, Gwang Seong; Shin, Jeong Hyun
2011-09-01
Chemical peeling is a dermatologic treatment for skin aging. However, the mechanism by which the chemical peel achieves its results is not clear. We investigated the effects of chemical peeling and the mechanism of wrinkle reduction in photoaged hairless mice skin. After inducing photoaged skin in hairless mice by repetitive ultraviolet-B irradiation applied over 14 weeks, we applied trichloroacetic acid (TCA) 30%, TCA 50%, and phenol on areas of the same size on the backs of the mice. Punch biopsies were obtained 7, 14, 28, and 60 days after the procedure for histologic and immunohistochemical analyses. Histologic examination showed an increase in dermal thickness, collagen fibers, and elastic fibers in the dermis of intervention groups compared with control groups. These increases were maintained significantly for 60 days. This study demonstrates that chemical peeling reduces wrinkles and regenerates skin by increasing dermal thickness and the amount of collagen and elastic fibers in photoaged skin. © 2011 The International Society of Dermatology.
Assessment of Occupational Health and Safety for a Gas Meter Manufacturing Plant
NASA Astrophysics Data System (ADS)
Korkmaz, Ece; Iskender, Gulen; Germirli Babuna, Fatos
2016-10-01
This study investigates the occupational health and safety for a gas meter manufacturing plant. The risk assessment and management study is applied to plastic injection and mounting departments of the factory through quantitative Fine Kinney method and the effect of adopting 5S workplace organization procedure on risk assessment is examined. The risk assessment reveals that there are 17 risks involved; 14 grouped in high risk class (immediate improvement as required action); 2 in significant (measures to be taken as required action) and one in possible risk class (monitoring as required action). Among 14 high risks, 4 can be reduced by 83 % to be grouped under possible class when 5S is applied. One significant risk is observed to be lowered by 78 % and considered as possible risk due to the application of 5S. As a result of either 67 or 50 % reductions in 7 high risks, these risks are converted to be members of significant risk group after 5S implications.
Wyszogrodzka, Monika; Haag, Rainer
2008-01-01
Dendrimers are an important class of polymeric materials for a broad range of applications in which monodispersity and multivalency are of interest. Here we report on a highly efficient synthetic route towards bifunctional polyglycerol dendrons on a multigram scale. Commercially available triglycerol (1), which is highly biocompatible, was used as starting material. By applying Williamson ether synthesis followed by an ozonolysis/reduction procedure, glycerol-based dendrons up to the fourth generation were prepared. The obtained products have a reactive core, which was further functionalized to the corresponding monoazido derivatives. By applying copper(I)-catalyzed 1,3-dipolar cycloaddition, so-called "click" coupling, a library of core-shell architectures was prepared. After removal of the 1,2-diol protecting groups, water-soluble core-shell architectures 24-27 of different generations were obtained in high yields. In the structure-transport relationship with Nile red we observe a clear dependence on core size and generation of the polyglycerol dendrons.
Characterization of Particle Combustion in a Rijke Burner
1988-11-01
Rijke Burner 14 3.1 Introduction 14 3.2 Acoustics 14 3.3 Eperimental Procedure 17 3.3.1 Apparatus 17 3.3.2 Data Reduction 19 3.4 Burner...response of the modified Rijke burner, 2) The experimental procedures, including design modifications of the burner and data reduction, and 3...have been modified and improved significantly. The following sections describe the major design changes made in the modified Rijke burner and its
Bayesian model reduction and empirical Bayes for group (DCM) studies.
Friston, Karl J; Litvak, Vladimir; Oswal, Ashwini; Razi, Adeel; Stephan, Klaas E; van Wijk, Bernadette C M; Ziegler, Gabriel; Zeidman, Peter
2016-03-01
This technical note describes some Bayesian procedures for the analysis of group studies that use nonlinear models at the first (within-subject) level - e.g., dynamic causal models - and linear models at subsequent (between-subject) levels. Its focus is on using Bayesian model reduction to finesse the inversion of multiple models of a single dataset or a single (hierarchical or empirical Bayes) model of multiple datasets. These applications of Bayesian model reduction allow one to consider parametric random effects and make inferences about group effects very efficiently (in a few seconds). We provide the relatively straightforward theoretical background to these procedures and illustrate their application using a worked example. This example uses a simulated mismatch negativity study of schizophrenia. We illustrate the robustness of Bayesian model reduction to violations of the (commonly used) Laplace assumption in dynamic causal modelling and show how its recursive application can facilitate both classical and Bayesian inference about group differences. Finally, we consider the application of these empirical Bayesian procedures to classification and prediction. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.
Solvent immersion imprint lithography: A high-performance, semi-automated procedure
Liyu, D. A.; Canul, A. J.; Vasdekis, A. E.
2017-01-01
We expand upon our recent, fundamental report on solvent immersion imprint lithography (SIIL) and describe a semi-automated and high-performance procedure for prototyping polymer microfluidics and optofluidics. The SIIL procedure minimizes manual intervention through a cost-effective (∼$200) and easy-to-assemble apparatus. We analyze the procedure's performance specifically for Poly (methyl methacrylate) microsystems and report repeatable polymer imprinting, bonding, and 3D functionalization in less than 5 min, down to 8 μm resolutions and 1:1 aspect ratios. In comparison to commercial approaches, the modified SIIL procedure enables substantial cost reductions, a 100-fold reduction in imprinting force requirements, as well as a more than 10-fold increase in bonding strength. We attribute these advantages to the directed polymer dissolution that strictly localizes at the polymer-solvent interface, as uniquely offered by SIIL. The described procedure opens new desktop prototyping opportunities, particularly for non-expert users performing live-cell imaging, flow-through catalysis, and on-chip gas detection. PMID:28798847
28 CFR 65.85 - Procedures for State or local governments applying for funding.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 28 Judicial Administration 2 2012-07-01 2012-07-01 false Procedures for State or local governments applying for funding. 65.85 Section 65.85 Judicial Administration DEPARTMENT OF JUSTICE (CONTINUED) EMERGENCY FEDERAL LAW ENFORCEMENT ASSISTANCE Immigration Emergency Fund § 65.85 Procedures for State or...
28 CFR 65.85 - Procedures for State or local governments applying for funding.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 28 Judicial Administration 2 2014-07-01 2014-07-01 false Procedures for State or local governments applying for funding. 65.85 Section 65.85 Judicial Administration DEPARTMENT OF JUSTICE (CONTINUED) EMERGENCY FEDERAL LAW ENFORCEMENT ASSISTANCE Immigration Emergency Fund § 65.85 Procedures for State or...
28 CFR 65.85 - Procedures for State or local governments applying for funding.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Procedures for State or local governments applying for funding. 65.85 Section 65.85 Judicial Administration DEPARTMENT OF JUSTICE (CONTINUED) EMERGENCY FEDERAL LAW ENFORCEMENT ASSISTANCE Immigration Emergency Fund § 65.85 Procedures for State or...
28 CFR 65.85 - Procedures for State or local governments applying for funding.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 28 Judicial Administration 2 2011-07-01 2011-07-01 false Procedures for State or local governments applying for funding. 65.85 Section 65.85 Judicial Administration DEPARTMENT OF JUSTICE (CONTINUED) EMERGENCY FEDERAL LAW ENFORCEMENT ASSISTANCE Immigration Emergency Fund § 65.85 Procedures for State or...
28 CFR 65.85 - Procedures for State or local governments applying for funding.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 28 Judicial Administration 2 2013-07-01 2013-07-01 false Procedures for State or local governments applying for funding. 65.85 Section 65.85 Judicial Administration DEPARTMENT OF JUSTICE (CONTINUED) EMERGENCY FEDERAL LAW ENFORCEMENT ASSISTANCE Immigration Emergency Fund § 65.85 Procedures for State or...
Communication Network Analysis Methods.
ERIC Educational Resources Information Center
Farace, Richard V.; Mabee, Timothy
This paper reviews a variety of analytic procedures that can be applied to network data, discussing the assumptions and usefulness of each procedure when applied to the complexity of human communication. Special attention is paid to the network properties measured or implied by each procedure. Factor analysis and multidimensional scaling are among…
NASA Astrophysics Data System (ADS)
Kim, Euiyoung; Cho, Maenghyo
2017-11-01
In most non-linear analyses, the construction of a system matrix uses a large amount of computation time, comparable to the computation time required by the solving process. If the process for computing non-linear internal force matrices is substituted with an effective equivalent model that enables the bypass of numerical integrations and assembly processes used in matrix construction, efficiency can be greatly enhanced. A stiffness evaluation procedure (STEP) establishes non-linear internal force models using polynomial formulations of displacements. To efficiently identify an equivalent model, the method has evolved such that it is based on a reduced-order system. The reduction process, however, makes the equivalent model difficult to parameterize, which significantly affects the efficiency of the optimization process. In this paper, therefore, a new STEP, E-STEP, is proposed. Based on the element-wise nature of the finite element model, the stiffness evaluation is carried out element-by-element in the full domain. Since the unit of computation for the stiffness evaluation is restricted by element size, and since the computation is independent, the equivalent model can be constructed efficiently in parallel, even in the full domain. Due to the element-wise nature of the construction procedure, the equivalent E-STEP model is easily characterized by design parameters. Various reduced-order modeling techniques can be applied to the equivalent system in a manner similar to how they are applied in the original system. The reduced-order model based on E-STEP is successfully demonstrated for the dynamic analyses of non-linear structural finite element systems under varying design parameters.
An overview of spray drift reduction testing of spray nozzles
USDA-ARS?s Scientific Manuscript database
The importance of the development and testing of drift reduction technologies (DRTs) is increasing. Common spray drift reduction technologies include spray nozzles and spray adjuvants. Following draft procedures developed for a DRT program, three spray nozzles were tested under high air speed cond...
Cingi Steps for preoperative computer-assisted image editing before reduction rhinoplasty.
Cingi, Can Cemal; Cingi, Cemal; Bayar Muluk, Nuray
2014-04-01
The aim of this work is to provide a stepwise systematic guide for a preoperative photo-editing procedure for rhinoplasty cases involving the cooperation of a graphic artist and a surgeon. One hundred female subjects who planned to undergo a reduction rhinoplasty operation were included in this study. The Cingi Steps for Preoperative Computer Imaging (CS-PCI) program, a stepwise systematic guide for image editing using Adobe PhotoShop's "liquify" effect, was applied to the rhinoplasty candidates. The stages of CS-PCI are as follows: (1) lowering the hump; (2) shortening the nose; (3) adjusting the tip projection, (4) perfecting the nasal dorsum, (5) creating a supratip break, and (6) exaggerating the tip projection and/or dorsal slope. Performing the Cingi Steps allows the patient to see what will happen during the operation and observe the final appearance of his or her nose. After the application of described steps, 71 patients (71%) accepted step 4, and 21 (21%) of them accepted step 5. Only 10 patients (10%) wanted to make additional changes to their operation plans. The main benefits of using this method is that it decreases the time needed by the surgeon to perform a graphic analysis, and it reduces the time required for the patient to reach a decision about the procedure. It is an easy and reliable method that will provide improved physician-patient communication, increased patient confidence, and enhanced surgical planning while limiting the time needed for planning. © 2014 ARS-AAOA, LLC.
Dexter, Franklin; Epstein, Richard H
2018-03-01
Diagnosis-related group (DRG) based reimbursement creates incentives for reduction in hospital length of stay (LOS). Such reductions might be accomplished by lesser incidences of discharges to home. However, we previously reported that, while controlling for DRG, each 1-day decrease in hospital median LOS was associated with lesser odds of transfer to a postacute care facility (P = .0008). The result, though, was limited to elective admissions, 15 common surgical DRGs, and the 2013 US National Readmission Database. We studied the same potential relationship between decreased LOS and postacute care using different methodology and over 2 different years. The observational study was performed using summary measures from the 2008 and 2014 US National Inpatient Sample, with 3 types of categories (strata): (1) Clinical Classifications Software's classes of procedures (CCS), (2) DRGs including a major operating room procedure during hospitalization, or (3) CCS limiting patients to those with US Medicare as the primary payer. Greater reductions in the mean LOS were associated with smaller percentages of patients with disposition to postacute care. Analyzed using 72 different CCSs, 174 DRGs, or 70 CCSs limited to Medicare patients, each pairwise reduction in the mean LOS by 1 day was associated with an estimated 2.6% ± 0.4%, 2.3% ± 0.3%, or 2.4% ± 0.3% (absolute) pairwise reduction in the mean incidence of use of postacute care, respectively. These 3 results obtained using bivariate weighted least squares linear regression were all P < .0001, as were the corresponding results obtained using unweighted linear regression or the Spearman rank correlation. In the United States, reductions in hospital LOS, averaged over many surgical procedures, are not accomplished through a greater incidence of use of postacute care.
SU-D-209-03: Radiation Dose Reduction Using Real-Time Image Processing in Interventional Radiology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kanal, K; Moirano, J; Zamora, D
Purpose: To characterize changes in radiation dose after introducing a new real-time image processing technology in interventional radiology systems. Methods: Interventional radiology (IR) procedures are increasingly complex, at times requiring substantial time and radiation dose. The risk of inducing tissue reactions as well as long-term stochastic effects such as radiation-induced cancer is not trivial. To reduce this risk, IR systems are increasingly equipped with dose reduction technologies.Recently, ClarityIQ (Philips Healthcare) technology was installed in our existing neuroradiology IR (NIR) and vascular IR (VIR) suites respectively. ClarityIQ includes real-time image processing that reduces noise/artifacts, enhances images, and sharpens edges while alsomore » reducing radiation dose rates. We reviewed 412 NIR (175 pre- and 237 post-ClarityIQ) procedures and 329 VIR (156 preand 173 post-ClarityIQ) procedures performed at our institution pre- and post-ClarityIQ implementation. NIR procedures were primarily classified as interventional or diagnostic. VIR procedures included drain port, drain placement, tube change, mesenteric, and implanted venous procedures. Air Kerma (AK in units of mGy) was documented for all the cases using a commercial radiation exposure management system. Results: When considering all NIR procedures, median AK decreased from 1194 mGy to 561 mGy. When considering all VIR procedures, median AK decreased from 49 to 14 mGy. Both NIR and VIR exhibited a decrease in AK exceeding 50% after ClarityIQ implementation, a statistically significant (p<0.05) difference. Of the 5 most common VIR procedures, all median AK values decreased, but significance (p<0.05) was only reached in venous access (N=53), angio mesenteric (N=41), and drain placement procedures (N=31). Conclusion: ClarityIQ can reduce dose significantly for both NIR and VIR procedures. Image quality was not assessed in conjunction with the dose reduction.« less
Selective Reduction: "A Soft Cover for Hard Choices" or Another Name for Abortion?
Rao, Radhika
2015-01-01
Selective reduction and abortion both involve the termination of fetal life, but they are classified by different designations to underscore the notion that they are regarded as fundamentally different medical procedures: the two are performed using distinct techniques by different types of physicians, upon women under very different circumstances, in order to further dramatically different objectives. Hence, the two procedures appear to call for a distinct moral calculus, and they have traditionally evoked contradictory reactions from society. This essay posits that despite their different appellations, selective reduction and abortion are essentially equivalent. © 2015 American Society of Law, Medicine & Ethics, Inc.
NASA Astrophysics Data System (ADS)
Pope, Crystal L.; Crenshaw, D. Michael; Fischer, Travis C.
2016-01-01
We present a preliminary analysis of the inflows and outflows in the narrow-line regions of nearby (z<0.1) AGN using observations from the Gemini-North telescope's Near-Infared Integral Field Spectrograph (NIFS). In addition to the standard reduction procedure for NIFS data cubes, these observations were treated for multiple sources of noise and artifacts from the adaptive optics observations and the NIFS instrument. This procedure included the following steps: correction of the differential atmospheric refraction, spatial resampling, low-pass Butterworth spatial filtering, removal of the "instrumental fingerprint", and the Richardson-Lucy deconvolution. We compare measurements from NIFS data cubes with and without the additional correction procedures to determine the effect of this data treatment on our scientific results.
A Rejection Principle for Sequential Tests of Multiple Hypotheses Controlling Familywise Error Rates
BARTROFF, JAY; SONG, JINLIN
2015-01-01
We present a unifying approach to multiple testing procedures for sequential (or streaming) data by giving sufficient conditions for a sequential multiple testing procedure to control the familywise error rate (FWER). Together we call these conditions a “rejection principle for sequential tests,” which we then apply to some existing sequential multiple testing procedures to give simplified understanding of their FWER control. Next the principle is applied to derive two new sequential multiple testing procedures with provable FWER control, one for testing hypotheses in order and another for closed testing. Examples of these new procedures are given by applying them to a chromosome aberration data set and to finding the maximum safe dose of a treatment. PMID:26985125
Nevada Applied Ecology Group procedures handbook for environmental transuranics
DOE Office of Scientific and Technical Information (OSTI.GOV)
White, M.G.; Dunaway, P.B.
The activities of the Nevada Applied Ecology Group (NAEG) integrated research studies of environmental plutonium and other transuranics at the Nevada Test Site have required many standardized field and laboratory procedures. These include sampling techniques, collection and preparation, radiochemical and wet chemistry analysis, data bank storage and reporting, and statistical considerations for environmental samples of soil, vegetation, resuspended particles, animals, and others. This document, printed in two volumes, includes most of the Nevada Applied Ecology Group standard procedures, with explanations as to the specific applications involved in the environmental studies. Where there is more than one document concerning a procedure,more » it has been included to indicate special studies or applications perhaps more complex than the routine standard sampling procedures utilized.« less
Nevada Applied Ecology Group procedures handbook for environmental transuranics
DOE Office of Scientific and Technical Information (OSTI.GOV)
White, M.G.; Dunaway, P.B.
The activities of the Nevada Applied Ecology Group (NAEG) integrated research studies of environmental plutonium and other transuranics at the Nevada Test Site have required many standardized field and laboratory procedures. These include sampling techniques, collection and preparation, radiochemical and wet chemistry analysis, data bank storage and reporting, and statistical considerations for environmental samples of soil, vegetation, resuspended particles, animals, and other biological material. This document, printed in two volumes, includes most of the Nevada Applied Ecology Group standard procedures, with explanations as to the specific applications involved in the environmental studies. Where there is more than one document concerningmore » a procedure, it has been included to indicate special studies or applications more complex than the routine standard sampling procedures utilized.« less
Yoshida, Masao; Takizawa, Kohei; Suzuki, Sho; Koike, Yoshiki; Nonaka, Satoru; Yamasaki, Yasushi; Minagawa, Takeyoshi; Sato, Chiko; Takeuchi, Chihiro; Watanabe, Ko; Kanzaki, Hiromitsu; Morimoto, Hiroyuki; Yano, Takafumi; Sudo, Kosuke; Mori, Keita; Gotoda, Takuji; Ono, Hiroyuki
2018-05-01
The aim of this study was to clarify whether dental floss clip (DFC) traction improves the technical outcomes of endoscopic submucosal dissection (ESD). A superiority, randomized control trial was conducted at 14 institutions across Japan. Patients with single gastric neoplasm meeting the indications of the Japanese guidelines for gastric treatment were enrolled and assigned to receive conventional ESD or DFC traction-assisted ESD (DFC-ESD). Randomization was performed according to a computer-generated random sequence with stratification by institution, tumor location, tumor size, and operator experience. The primary endpoint was ESD procedure time, defined as the time from the start of the submucosal injection to the end of the tumor removal procedure. Between July 2015 and September 2016, 640 patients underwent randomization. Of these, 316 patients who underwent conventional ESD and 319 patients who underwent DFC-ESD were included in our analysis. The mean ESD procedure time was 60.7 and 58.1 minutes for conventional ESD and DFC-ESD, respectively (P = .45). Perforation was less frequent in the DFC-ESD group (2.2% vs .3%, P = .04). For lesions located in the greater curvature of the upper or middle stomach, the mean procedure time was significantly shorter in the DFC-ESD group (104.1 vs 57.2 minutes, P = .01). Our findings suggest that DFC-ESD does not result in shorter procedure time in the overall patient population, but it can reduce the risk of perforation. When selectively applied to lesions located in the greater curvature of the upper or middle stomach, DFC-ESD provides a remarkable reduction in procedure time. Copyright © 2018 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.
Chemical purification of lanthanides for low-background experiments
NASA Astrophysics Data System (ADS)
Boiko, R. S.
2017-10-01
There are many potentially active isotopes among the lanthanide elements which are possible to use for low-background experiments to search for double β decay, dark matter, to investigate rare α and β decays. These kind of experiments require very low level of radioactive contamination, but commercially available compounds of lanthanides are always contamined by uranium, thorium, radium, potassium, etc. A simple chemical method based on liquid-liquid extraction has been applied for the purification of CeO2, Nd2O3 and Gd˙2O˙3 from radioactive traces. Detailed schemes of purification procedure are described. Measurements by using HPGe spectrometry demonstrate high efficiency in K, Ra, Th, U contaminations reduction on at least one order of magnitude.
Atanassova, Vassia; Sotirova, Evdokia; Doukovska, Lyubka; Bureva, Veselina; Mavrov, Deyan; Tomov, Jivko
2017-01-01
The approach of InterCriteria Analysis (ICA) was applied for the aim of reducing the set of variables on the input of a neural network, taking into account the fact that their large number increases the number of neurons in the network, thus making them unusable for hardware implementation. Here, for the first time, with the help of the ICA method, correlations between triples of the input parameters for training of the neural networks were obtained. In this case, we use the approach of ICA for data preprocessing, which may yield reduction of the total time for training the neural networks, hence, the time for the network's processing of data and images. PMID:28874908
NASA Technical Reports Server (NTRS)
Felici, Helene M.; Drela, Mark
1993-01-01
A new approach based on the coupling of an Eulerian and a Lagrangian solver, aimed at reducing the numerical diffusion errors of standard Eulerian time-marching finite-volume solvers, is presented. The approach is applied to the computation of the secondary flow in two bent pipes and the flow around a 3D wing. Using convective point markers the Lagrangian approach provides a correction of the basic Eulerian solution. The Eulerian flow in turn integrates in time the Lagrangian state-vector. A comparison of coarse and fine grid Eulerian solutions makes it possible to identify numerical diffusion. It is shown that the Eulerian/Lagrangian approach is an effective method for reducing numerical diffusion errors.
Time stress measurement device: system design and synthesis
NASA Astrophysics Data System (ADS)
Harchani, Noursaied; Jimenez, Fernando; Al-Mohammed, Mohammed; Esteve, Daniel; Courvoisier, M.
2000-04-01
System design methodology becomes a strategic activity in the industrial competition. Obtaining substantial reduction of time to market for complex and reliable products is one of the priorities for the manufacturers. Top down design, automated generation of architecture, co-design, virtual prototyping, etc. are already identified as research topics which have to be privileged. To be efficient, each theoretical contribution must be inserted in a global procedure of project management where complementary elements such as marketing, technico-economic survey, road-mapping, internal know-how,.. must be considered. In this context, this paper will present a design methodology starting from the requirement statement until the technical realization of the product, and applied to the design of a Time Stress Measurement Device for the observation of aeronautical mechanical systems.
Cost effectiveness of a medical digital library.
Roussel, F; Darmoni, S J; Thirion, B
2001-01-01
The rapid increase in the price of electronic journals has made the optimization of collection management an urgent task. As there is currently no standard procedure for the evaluation of this problem, we applied the Reading Factor (RF), an electronically computed indicator used for consultation of individual articles. The aim of our study was to assess the cost effective impact of modifications in our digital library (i.e. change of access from the Intranet to the Internet or change in editorial policy). The digital OVID library at Rouen University Hospital continues to be cost-effective in comparison with the interlibrary loan costs. Moreover, when electronic versions are offered alongside a limited amount of interlibrary loans, a reduction in library costs was observed.
NASA Technical Reports Server (NTRS)
Sreekanta Murthy, T.
1992-01-01
Results of the investigation of formal nonlinear programming-based numerical optimization techniques of helicopter airframe vibration reduction are summarized. The objective and constraint function and the sensitivity expressions used in the formulation of airframe vibration optimization problems are presented and discussed. Implementation of a new computational procedure based on MSC/NASTRAN and CONMIN in a computer program system called DYNOPT for optimizing airframes subject to strength, frequency, dynamic response, and dynamic stress constraints is described. An optimization methodology is proposed which is thought to provide a new way of applying formal optimization techniques during the various phases of the airframe design process. Numerical results obtained from the application of the DYNOPT optimization code to a helicopter airframe are discussed.
40 CFR 76.15 - Test methods and procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 17 2012-07-01 2012-07-01 false Test methods and procedures. 76.15 Section 76.15 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) ACID RAIN NITROGEN OXIDES EMISSION REDUCTION PROGRAM § 76.15 Test methods and procedures. (a) The...
40 CFR 76.15 - Test methods and procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 17 2014-07-01 2014-07-01 false Test methods and procedures. 76.15 Section 76.15 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) ACID RAIN NITROGEN OXIDES EMISSION REDUCTION PROGRAM § 76.15 Test methods and procedures. (a) The...
40 CFR 76.15 - Test methods and procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Test methods and procedures. 76.15 Section 76.15 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) ACID RAIN NITROGEN OXIDES EMISSION REDUCTION PROGRAM § 76.15 Test methods and procedures. (a) The...
40 CFR 76.15 - Test methods and procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 16 2011-07-01 2011-07-01 false Test methods and procedures. 76.15 Section 76.15 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) ACID RAIN NITROGEN OXIDES EMISSION REDUCTION PROGRAM § 76.15 Test methods and procedures. (a) The...
40 CFR 76.15 - Test methods and procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 17 2013-07-01 2013-07-01 false Test methods and procedures. 76.15 Section 76.15 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) ACID RAIN NITROGEN OXIDES EMISSION REDUCTION PROGRAM § 76.15 Test methods and procedures. (a) The...
[Failure mode effect analysis applied to preparation of intravenous cytostatics].
Santos-Rubio, M D; Marín-Gil, R; Muñoz-de la Corte, R; Velázquez-López, M D; Gil-Navarro, M V; Bautista-Paloma, F J
2016-01-01
To proactively identify risks in the preparation of intravenous cytostatic drugs, and to prioritise and establish measures to improve safety procedures. Failure Mode Effect Analysis methodology was used. A multidisciplinary team identified potential failure modes of the procedure through a brainstorming session. The impact associated with each failure mode was assessed with the Risk Priority Number (RPN), which involves three variables: occurrence, severity, and detectability. Improvement measures were established for all identified failure modes, with those with RPN>100 considered critical. The final RPN (theoretical) that would result from the proposed measures was also calculated and the process was redesigned. A total of 34 failure modes were identified. The initial accumulated RPN was 3022 (range: 3-252), and after recommended actions the final RPN was 1292 (range: 3-189). RPN scores >100 were obtained in 13 failure modes; only the dispensing sub-process was free of critical points (RPN>100). A final reduction of RPN>50% was achieved in 9 failure modes. This prospective risk analysis methodology allows the weaknesses of the procedure to be prioritised, optimize use of resources, and a substantial improvement in the safety of the preparation of cytostatic drugs through the introduction of double checking and intermediate product labelling. Copyright © 2015 SECA. Published by Elsevier Espana. All rights reserved.
Kloeze, C; Klompenhouwer, E G; Brands, P J M; van Sambeek, M R H M; Cuypers, P W M; Teijink, J A W
2014-03-01
Because of the increasing number of interventional endovascular procedures with fluoroscopy and the corresponding high annual dose for interventionalists, additional dose-protecting measures are desirable. The purpose of this study was to evaluate the effect of disposable radiation-absorbing surgical drapes in reducing scatter radiation exposure for interventionalists and supporting staff during an endovascular aneurysm repair (EVAR) procedure. This was a randomized control trial in which 36 EVAR procedures were randomized between execution with and without disposable radiation-absorbing surgical drapes (Radpad: Worldwide Innovations & Technologies, Inc., Kansas City, US, type 5511A). Dosimetric measurements were performed on the interventionalist (hand and chest) and theatre nurse (chest) with and without the use of the drapes to obtain the dose reduction and effect on the annual dose caused by the drapes. Use of disposable radiation-absorbing surgical drapes resulted in dose reductions of 49%, 55%, and 48%, respectively, measured on the hand and chest of the interventionalist and the chest of the theatre nurse. The use of disposable radiation-absorbing surgical drapes significantly reduces scatter radiation exposure for both the interventionalist and the supporting staff during EVAR procedures. Copyright © 2013 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.
Digital methods for reducing radiation exposure during medical fluoroscopy
NASA Astrophysics Data System (ADS)
Edmonds, Ernest W.; Rowlands, John A.; Hynes, David M.; Toth, B. D.; Porter, Anthony J.
1990-07-01
There is increased concern over radiation exposure to the general population from many sources. One of the most significant sources is that received by the patient during medical diagnostic procedures, and of these, the procedure with the greatest potential hazard is fluoroscopy. The legal limit for fluoroscopy in most jurisdictions is SR per minute skin exposure rate. Fluoroscopes are often operated in excess of this figure, and in the case of interventional procedures, fluorocopy times may exceed 20 minutes. With improvements in medical technology these procedures are being performed more often, and also are being carried out on younger age groups. Radiation exposure during fluoroscopy, both to patient and operator, is therefore becoming a matter of increasing concern to regulating authorities, and it is incumbent on us to develop digital technology to minimise the radiation hazard in these procedures. This paper explores the technical options available for radiation exposure reduction, including pulsed fluoroscopy, digital noise reduction, or simple reduction in exposure rate to the x-ray image intensifier. We also discuss educational aspects of fluoroscopy which radiologists should be aware of which can be more important than the technological solutions. A "work in progress" report gives a completely new approach to the implementation of a large number of possible digital algorithms, for the investigation of clinical efficacy.
Zhang, Hui; Lu, Naiji; Feng, Changyong; Thurston, Sally W; Xia, Yinglin; Zhu, Liang; Tu, Xin M
2011-09-10
The generalized linear mixed-effects model (GLMM) is a popular paradigm to extend models for cross-sectional data to a longitudinal setting. When applied to modeling binary responses, different software packages and even different procedures within a package may give quite different results. In this report, we describe the statistical approaches that underlie these different procedures and discuss their strengths and weaknesses when applied to fit correlated binary responses. We then illustrate these considerations by applying these procedures implemented in some popular software packages to simulated and real study data. Our simulation results indicate a lack of reliability for most of the procedures considered, which carries significant implications for applying such popular software packages in practice. Copyright © 2011 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Chen, Shujuan; Li, Nan; Zhang, Xinshen; Yang, Dongjing; Jiang, Heimei
2015-03-01
A simple and new low pressure ion chromatography combined with flow injection spectrophotometric procedure for determining Fe(II) and Fe(III) was established. It is based on the selective adsorption of low pressure ion chromatography column to Fe(II) and Fe(III), the online reduction reaction of Fe(III) and the reaction of Fe(II) in sodium acetate with phenanthroline, resulting in an intense orange complex with a suitable absorption at 515 nm. Various chemical (such as the concentration of colour reagent, eluant and reductive agent) and instrumental parameters (reaction coil length, reductive coil length and wavelength) were studied and were optimized. Under the optimum conditions calibration graph of Fe(II)/Fe(III) was linear in the Fe(II)/Fe(III) range of 0.040-1.0 mg/L. The detection limit of Fe(III) and Fe(II) was respectively 3.09 and 1.55 μg/L, the relative standard deviation (n = 10) of Fe(II) and Fe(III) 1.89% and 1.90% for 0.5 mg/L of Fe(II) and Fe(III) respectively. About 2.5 samples in 1 h can be analyzed. The interfering effects of various chemical species were studied. The method was successfully applied in the determination of water samples.
Crystal field parameters in UCI 4: Experiment versus theory
NASA Astrophysics Data System (ADS)
Zolnierek, Z.; Gajek, Z.; Malek, Ch. Khan
1984-08-01
Crystal field effect on U 4+ ion with the 3H 4 ground term in tetragonal ligand field of UCl 4 has been studied in detail. Crystal field parameters determined experimentally from optical spectroscopy and magnetic susceptibility are in good agreement with CFP sets derived from the modified point charge model and the ab initio method. Theoretical calculations lead to overestimating the A44< r4> and lowering the A02< r2> values in comparison to those found in the experiments. The discrepancies are, however, within an accuracy of calculations. A large reduction of expectation values of the magnetic moment operator for the eigenvectors of lowest CF levels (17.8%), determined from magnetic susceptibility, cannot be attributed to the overlap and covalency effects only. The detailed calculations have shown that the latter effects provide about 4.6% reduction of respective matrix elements, and the applied J-J mixing procedure increases this factor up to 6.5%. Since similar, as in UCl 4, reduction factor(≈15%) has already been observed in a number of different uranium compounds, it seems likely that this feature is involved in the intrinsic properties of the U 4+ ion. We endeavor to explain this effect in terms of configuration interaction mechanisms.
A new algorithm for five-hole probe calibration, data reduction, and uncertainty analysis
NASA Technical Reports Server (NTRS)
Reichert, Bruce A.; Wendt, Bruce J.
1994-01-01
A new algorithm for five-hole probe calibration and data reduction using a non-nulling method is developed. The significant features of the algorithm are: (1) two components of the unit vector in the flow direction replace pitch and yaw angles as flow direction variables; and (2) symmetry rules are developed that greatly simplify Taylor's series representations of the calibration data. In data reduction, four pressure coefficients allow total pressure, static pressure, and flow direction to be calculated directly. The new algorithm's simplicity permits an analytical treatment of the propagation of uncertainty in five-hole probe measurement. The objectives of the uncertainty analysis are to quantify uncertainty of five-hole results (e.g., total pressure, static pressure, and flow direction) and determine the dependence of the result uncertainty on the uncertainty of all underlying experimental and calibration measurands. This study outlines a general procedure that other researchers may use to determine five-hole probe result uncertainty and provides guidance to improve measurement technique. The new algorithm is applied to calibrate and reduce data from a rake of five-hole probes. Here, ten individual probes are mounted on a single probe shaft and used simultaneously. Use of this probe is made practical by the simplicity afforded by this algorithm.
A test procedure for evaluating surgical hand disinfection.
Babb, J R; Davies, J G; Ayliffe, G A
1991-06-01
A technique for assessing the immediate and prolonged efficacy of surgical scrubs and alcoholic hand rubs is described. A mean baseline count is obtained from all volunteers and logarithmic reductions in resident skin flora immediately after one or more applications, and after wearing gloves for 3 h, are measured. Loose-fitting surgical gloves are used for sampling resident flora. Preparations were applied using a standard technique for 2 min, apart from one test with 70% isopropanol (IPA) in which the application time was 30 s. Two studies are described, one of which compared four chlorhexidine scrubs, and the second 70% IPA, 7.5% povidone-iodine scrub, 2% triclosan cleanser and unmedicated bar soap. In spite of their constituent similarity, the four chlorhexidine scrubs varied considerably in efficacy and user acceptability. A 2 min application of 70% IPA was the most effective treatment, and gave log10 reductions of 1.65 for immediate and 1.58 for prolonged effect. This was marginally more effective than a 30 s application, but the difference was not significant. 'Hibiscrub' was the most effective aqueous formulation and gave reductions of 1.01 for immediate effect and 1.16 for prolonged effect. The test described could be used by reference centres and manufacturers to assess the efficacy of new and existing surgical hand disinfection formulations.
Kelly, David; Budd, Kenneth; Lefebvre, Daniel D.
2006-01-01
The biotransformation of HgII in pH-controlled and aerated algal cultures was investigated. Previous researchers have observed losses in Hg detection in vitro with the addition of cysteine under acid reduction conditions in the presence of SnCl2. They proposed that this was the effect of Hg-thiol complexing. The present study found that cysteine-Hg, protein and nonprotein thiol chelates, and nucleoside chelates of Hg were all fully detectable under acid reduction conditions without previous digestion. Furthermore, organic (R-Hg) mercury compounds could not be detected under either the acid or alkaline reduction conditions, and only β-HgS was detected under alkaline and not under acid SnCl2 reduction conditions. The blue-green alga Limnothrix planctonica biotransformed the bulk of HgII applied as HgCl2 into a form with the analytical properties of β-HgS. Similar results were obtained for the eukaryotic alga Selenastrum minutum. No evidence for the synthesis of organomercurials such as CH3Hg+ was obtained from analysis of either airstream or biomass samples under the aerobic conditions of the study. An analytical procedure that involved both acid and alkaline reduction was developed. It provides the first selective method for the determination of β-HgS in biological samples. Under aerobic conditions, HgII is biotransformed mainly into β-HgS (meta-cinnabar), and this occurs in both prokaryotic and eukaryotic algae. This has important implications with respect to identification of mercury species and cycling in aquatic habitats. PMID:16391065
Kelly, David; Budd, Kenneth; Lefebvre, Daniel D
2006-01-01
The biotransformation of Hg(II) in pH-controlled and aerated algal cultures was investigated. Previous researchers have observed losses in Hg detection in vitro with the addition of cysteine under acid reduction conditions in the presence of SnCl2. They proposed that this was the effect of Hg-thiol complexing. The present study found that cysteine-Hg, protein and nonprotein thiol chelates, and nucleoside chelates of Hg were all fully detectable under acid reduction conditions without previous digestion. Furthermore, organic (R-Hg) mercury compounds could not be detected under either the acid or alkaline reduction conditions, and only beta-HgS was detected under alkaline and not under acid SnCl2 reduction conditions. The blue-green alga Limnothrix planctonica biotransformed the bulk of Hg(II) applied as HgCl2 into a form with the analytical properties of beta-HgS. Similar results were obtained for the eukaryotic alga Selenastrum minutum. No evidence for the synthesis of organomercurials such as CH3Hg+ was obtained from analysis of either airstream or biomass samples under the aerobic conditions of the study. An analytical procedure that involved both acid and alkaline reduction was developed. It provides the first selective method for the determination of beta-HgS in biological samples. Under aerobic conditions, Hg(II) is biotransformed mainly into beta-HgS (meta-cinnabar), and this occurs in both prokaryotic and eukaryotic algae. This has important implications with respect to identification of mercury species and cycling in aquatic habitats.
Honeychurch, Kevin C; Davidson, Gwen M; Brown, Emma; Hart, John P
2015-01-01
Rohypnol (flunitrazepam) has been successfully determined in coffee by high performance liquid chromatography dual electrode detection (LC-DED) in the dual reductive mode. Initial studies were performed to optimise the chromatographic conditions and these were found to be 50% acetonitrile, 50% 50 mM pH 2.0 phosphate buffer at a flow rate of 0.75 mL min(-1), employing a Hypersil C18, 5 μm, 250 mm × 4.6 mm column. Cyclic voltammetric studies were made to ascertain the redox behaviour of Rohypnol at a glassy carbon electrode over the pH range 2-12. Hydrodynamic voltammetry was used to optimise the applied potential at the generator and detector cells; these were identified to be -2.4 V and +0.8 V for the redox mode and -2.4 V and -0.1 V for the dual reductive mode respectively. A linear range of 0.5-100 μg mL(-1), with a detection limit of 20 ng mL(-1) was obtained for the dual reductive mode. Further studies were then performed to identify the optimum conditions required for the LC-DED determination of Rohypnol in beverage samples. A convenient and rapid method for the determination of Rohypnol in beverage samples was developed using a simple sample pre-treatment procedure. A recovery of 95.5% was achieved for a sample of white coffee fortified at 9.6 μg mL(-1) Rohypnol. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
1973-01-01
Aircraft and airport noise reduction technology programs conducted by NASA are presented. The subjects discussed are: (1) effects of aircraft noise on individuals and communities, (2) status of aircraft source noise technology, (3) operational procedures to reduce the impact of aircraft noise, and (4) NASA relations with military services in aircraft noise problems. References to more detailed technical literature on the subjects discussed are included.
NASA Astrophysics Data System (ADS)
Xiao, Gang; Zhao, Yilin; Li, Linghui; Pratt, Jonathan O.; Su, Haijia; Tan, Tianwei
2018-04-01
This paper presents a facile, rapid, and controllable procedure for the recovery of trace Ag+ ions and in situ assembly of well dispersed Ag nanoparticles on chitosan-TiO2 composites through bioaffinity adsorption followed by photocatalytic reduction. The prepared Ag nanoparticles are proven to be efficient and recyclable nanocatalysts for the reduction of 4-nitrophenol to 4-aminophenol in the presence of NaBH4. Well dispersed quasi-spherical Ag NPs are synthesized in 20 min in the designed inner-irradiated photocatalytic system under a wide range of Ag+ concentrations (50-200 mg l-1), temperatures (10 °C-25 °C) conditions, and UV or visible light irradiation. The synthesized Ag NPs can catalyze the reduction of 4-nitrophenol by NaBH4 at 100% conversion in 120 min and preserve the catalytic activity in five successive cycles. This procedure for trace Ag+ ions recovery and Ag NPs assembly has the potential to be scaled up for the mass production of recyclable Ag nanocatalysts. The present work provides a green and efficient procedure for the conversion of hazardous 4-nitrophenol to industrially important 4-aminophenol and also sheds a light on designing scaled-up procedures for treating high volumes of wastewater with dilute heavy metals to produce recyclable metallic nanocatalysts in aqueous systems.
Efficacy of Cleaning and Disinfection Procedures in a Zebrafish (Danio rerio) Facility
Garcia, Rachel L; Sanders, George E
2011-01-01
Appropriate cleaning and disinfection procedures in zebrafish (Danio rerio) laboratories are crucial in preventing the spread of aquatic animal pathogens and minimizing the build-up of waste products and biologic matter. The procedures selected should accomplish these goals and incorporate the individual needs of various laboratories. In this study of a single zebrafish facility, we assessed the efficacy of 2 different cleaning and disinfection procedures for nets, tanks, and lids. ATP levels were used as a surrogate biomarker for microbial burden. We measured the number of relative light units (RLU), as an expression of the amount of ATP present, on items before and after disinfection and calculated the percentage reduction. We compared daily replacement of a commercial net disinfection product in J lab with weekly replacement in H lab and found a 96.6% reduction in RLU in H lab and a 91.2% reduction in J lab. These results indicate that either replacement schedule is effective. Evaluation of tanks and lids soaked in a bleach disinfection bath for 30 or 60 min revealed a 99.7% reduction in RLU at 30 min compared with 97.1% at 60 min. Therefore a 30-min soak in a bleach bath achieved a similar level of disinfection as did a 60-min soak. The current results demonstrate that these cleaning and disinfection methods are efficacious. PMID:22330783
Efficacy of cleaning and disinfection procedures in a zebrafish (Danio rerio) facility.
Garcia, Rachel L; Sanders, George E
2011-11-01
Appropriate cleaning and disinfection procedures in zebrafish (Danio rerio) laboratories are crucial in preventing the spread of aquatic animal pathogens and minimizing the build-up of waste products and biologic matter. The procedures selected should accomplish these goals and incorporate the individual needs of various laboratories. In this study of a single zebrafish facility, we assessed the efficacy of 2 different cleaning and disinfection procedures for nets, tanks, and lids. ATP levels were used as a surrogate biomarker for microbial burden. We measured the number of relative light units (RLU), as an expression of the amount of ATP present, on items before and after disinfection and calculated the percentage reduction. We compared daily replacement of a commercial net disinfection product in J lab with weekly replacement in H lab and found a 96.6% reduction in RLU in H lab and a 91.2% reduction in J lab. These results indicate that either replacement schedule is effective. Evaluation of tanks and lids soaked in a bleach disinfection bath for 30 or 60 min revealed a 99.7% reduction in RLU at 30 min compared with 97.1% at 60 min. Therefore a 30-min soak in a bleach bath achieved a similar level of disinfection as did a 60-min soak. The current results demonstrate that these cleaning and disinfection methods are efficacious.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-16
... required by the Paperwork Reduction Act of 1995, Public Law 104-13 (44 U.S.C. 3506(c)(2)(A)). Currently... Corporations, and Revenue Procedure 2004-48, Deemed Corporate Election for Late Electing S Corporations. DATES...-45, Late Election Relief for S Corporations, and Revenue Procedure 2004-48, Deemed Corporate Election...
NASA Technical Reports Server (NTRS)
Seshadri, Banavara R.; Smith, Stephen W.
2007-01-01
Variation in constraint through the thickness of a specimen effects the cyclic crack-tip-opening displacement (DELTA CTOD). DELTA CTOD is a valuable measure of crack growth behavior, indicating closure development, constraint variations and load history effects. Fatigue loading with a continual load reduction was used to simulate the load history associated with fatigue crack growth threshold measurements. The constraint effect on the estimated DELTA CTOD is studied by carrying out three-dimensional elastic-plastic finite element simulations. The analysis involves numerical simulation of different standard fatigue threshold test schemes to determine how each test scheme affects DELTA CTOD. The American Society for Testing and Materials (ASTM) prescribes standard load reduction procedures for threshold testing using either the constant stress ratio (R) or constant maximum stress intensity (K(sub max)) methods. Different specimen types defined in the standard, namely the compact tension, C(T), and middle cracked tension, M(T), specimens were used in this simulation. The threshold simulations were conducted with different initial K(sub max) values to study its effect on estimated DELTA CTOD. During each simulation, the DELTA CTOD was estimated at every load increment during the load reduction procedure. Previous numerical simulation results indicate that the constant R load reduction method generates a plastic wake resulting in remote crack closure during unloading. Upon reloading, this remote contact location was observed to remain in contact well after the crack tip was fully open. The final region to open is located at the point at which the load reduction was initiated and at the free surface of the specimen. However, simulations carried out using the constant Kmax load reduction procedure did not indicate remote crack closure. Previous analysis results using various starting K(sub max) values and different load reduction rates have indicated DELTA CTOD is independent of specimen size. A study of the effect of specimen thickness and geometry on the measured DELTA CTOD for various load reduction procedures and its implication in the estimation of fatigue crack growth threshold values is discussed.
38 CFR 21.7320 - Procedural protection; reduction following loss of dependent.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 38 Pensions, Bonuses, and Veterans' Relief 2 2010-07-01 2010-07-01 false Procedural protection... Educational Assistance Program (Montgomery GI Bill-Active Duty) Administrative § 21.7320 Procedural protection... veteran or his or her fiduciary with knowledge or notice that the information would be used to determine...
de Kerviler, S; Hüsler, R; Banic, A; Constantinescu, M A
2009-05-01
This study analyzed the impact of weight reduction method, preoperative, and intraoperative variables on the outcome of reconstructive body contouring surgery following massive weight reduction. All patients presenting with a maximal BMI >/=35 kg/m(2) before weight reduction who underwent body contouring surgery of the trunk following massive weight loss (excess body mass index loss (EBMIL) >/= 30%) between January 2002 and June 2007 were retrospectively analyzed. Incomplete records or follow-up led to exclusion. Statistical analysis focused on weight reduction method and pre-, intra-, and postoperative risk factors. The outcome was compared to current literature results. A total of 104 patients were included (87 female and 17 male; mean age 47.9 years). Massive weight reduction was achieved through bariatric surgery in 62 patients (59.6%) and dietetically in 42 patients (40.4%). Dietetically achieved excess body mass index loss (EBMIL) was 94.20% and in this cohort higher than surgically induced reduction EBMIL 80.80% (p < 0.01). Bariatric surgery did not present increased risks for complications for the secondary body contouring procedures. The observed complications (26.9%) were analyzed for risk factors. Total tissue resection weight was a significant risk factor (p < 0.05). Preoperative BMI had an impact on infections (p < 0.05). No impact on the postoperative outcome was detected in EBMIL, maximal BMI, smoking, hemoglobin, blood loss, body contouring technique or operation time. Corrective procedures were performed in 11 patients (10.6%). The results were compared to recent data. Bariatric surgery does not increase risks for complications in subsequent body contouring procedures when compared to massive dietetic weight reduction.
17 CFR 202.9 - Small entity enforcement penalty reduction policy.
Code of Federal Regulations, 2010 CFR
2010-04-01
... penalty reduction policy. 202.9 Section 202.9 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION INFORMAL AND OTHER PROCEDURES § 202.9 Small entity enforcement penalty reduction policy. The Commission's policy with respect to whether to reduce or assess civil money penalties against a small entity...
DeVille, J Brian; Svinarich, J Thomas; Dan, Dan; Wickliffe, Andrew; Kantipudi, Charan; Lim, Hae W; Plummer, Lisa; Baker, James; Kowalski, Marcin; Baydoun, Hassan; Jenkins, Mark; Chang-Sing, Peter
2014-06-01
Point-to-point focal radiofrequency (RF) catheter ablation for aberrant pulmonary vein triggers that manifest into atrial fibrillation (AF) is the traditional method for treating symptomatic drug-resistant paroxysmal AF (PAF) when an ablation procedure is warranted. More recently, pulmonary vein isolation (PVI) using the cryoballoon has been demonstrated to be safe and effective (STOP AF clinical trial). Currently, two small studies have reviewed the procedural efficiency when comparing cryoballoon to focal RF catheter ablation procedures; however, no multicenter study has yet reported on this comparison of the two types of ablation catheters. A multicenter retrospective chart extraction and evaluation was conducted at seven geographically mixed cardiac care centers. The study examined procedural variables during ablation for PVI in PAF patients. In several procedural measurements, the two modalities were comparable in efficiencies, including: acute PVI >96%; length of hospital stay at approximately 27 hours; and about 30% usage of adenosine after procedural testing. However, when compared to RF catheters, the cryoballoon procedure demonstrated a 13% reduction in laboratory occupancy time (247 min vs 283 min), a 13% reduction in procedure time (174 min vs 200 min), and a 21% reduction in fluoroscopy time (33 min vs 42 min). Additionally, when comparing the material usage of both cryoballoon and RF catheters, the cryoballoon used more radiopaque contrast agent (78 cc vs 29 cc) while using less intraprocedural saline (1234 cc vs 2386 cc), intracardiac echocardiography (88% vs 99%), three-dimensional electroanatomic mapping (30% vs 87%), and fewer transseptal punctures (1.5 vs 1.9). This study is the first United States multicenter examination to report the procedural comparisons between the cryoballoon and focal RF catheters when used for the treatment of PAF patients. In this hospital chart review study, potential advantages were found when operating the cryoballoon with regard to hospital resource allocation. There was no statistical difference between cryoballoon and RF catheters for acute PVI success during the ablation procedure.
Low-level laser therapy for fat layer reduction: a comprehensive review.
Avci, Pinar; Nyame, Theodore T; Gupta, Gaurav K; Sadasivam, Magesh; Hamblin, Michael R
2013-08-01
Low-level laser (light) therapy (LLLT) is a noninvasive, nonthermal approach to disorders requiring reduction of pain and inflammation and stimulation of healing and tissue regeneration. Within the last decade, LLLT started being investigated as an adjuvant to liposuction, for noninvasive body contouring, reduction of cellulite, and improvement of blood lipid profile. LLLT may also aid autologous fat transfer procedures by enhancing the viability of adipocytes. However the underlying mechanism of actions for such effects still seems to be unclear. It is important, therefore, to understand the potential efficacy and proposed mechanism of actions of this new procedure for fat reduction. A review of the literature associated with applications of LLLT related to fat layer reduction was performed to evaluate the findings from pre-clinical and clinical studies with respect to the mechanism of action, efficacy, and safety. The studies as of today suggest that LLLT has a potential to be used in fat and cellulite reduction as well as in improvement of blood lipid profile without any significant side effects. One of the main proposed mechanism of actions is based upon production of transient pores in adipocytes, allowing lipids to leak out. Another is through activation of the complement cascade which could cause induction of adipocyte apoptosis and subsequent release of lipids. Although the present studies have demonstrated safety and efficacy of LLLT in fat layer reduction, studies demonstrating the efficacy of LLLT as a stand-alone procedure are still inadequate. Moreover, further studies are necessary to identify the mechanism of action. Copyright © 2013 Wiley Periodicals, Inc.
Low-Level Laser Therapy for Fat Layer Reduction: A Comprehensive Review
Avci, Pinar; Nyame, Theodore T.; Gupta, Gaurav K.; Sadasivam, Magesh; Hamblin, Michael R.
2013-01-01
Background and Objective Low-level laser (light) therapy (LLLT) is a noninvasive, nonthermal approach to disorders requiring reduction of pain and inflammation and stimulation of healing and tissue regeneration. Within the last decade, LLLT started being investigated as an adjuvant to liposuction, for noninvasive body contouring, reduction of cellulite, and improvement of blood lipid profile. LLLT may also aid autologous fat transfer procedures by enhancing the viability of adipocytes. However the underlying mechanism of actions for such effects still seems to be unclear. It is important, therefore, to understand the potential efficacy and proposed mechanism of actions of this new procedure for fat reduction. Materials and Methods A review of the literature associated with applications of LLLT related to fat layer reduction was performed to evaluate the findings from pre-clinical and clinical studies with respect to the mechanism of action, efficacy, and safety. Results The studies as of today suggest that LLLT has a potential to be used in fat and cellulite reduction as well as in improvement of blood lipid profile without any significant side effects. One of the main proposed mechanism of actions is based upon production of transient pores in adipocytes, allowing lipids to leak out. Another is through activation of the complement cascade which could cause induction of adipocyte apoptosis and subsequent release of lipids. Conclusion Although the present studies have demonstrated safety and efficacy of LLLT in fat layer reduction, studies demonstrating the efficacy of LLLT as a stand-alone procedure are still inadequate. Moreover, further studies are necessary to identify the mechanism of action. PMID:23749426
Shimonov, Mordechai; Schechter, Pinhas; Boaz, Mona; Waintrob, Ronen; Ezri, Tiberiu
2017-03-01
The effect of body mass index (BMI) reduction following bariatric surgery on subsequent airway management has not been investigated. This study aimed to investigate the association between BMI reduction and airway assessment and management measured by Mallampati class (MC) and laryngoscopy grade (LG). We conducted a retrospective study over 6 years to compare the BMI changes, MC and LG in patients having weight reduction bariatric surgery followed by subsequent surgery. Data was extracted from the anesthesia records of patients undergoing laparoscopic band insertion (LBI) and laparoscopic sleeve gastrectomy (LSG). Difficult airway was defined as Malampati class 3 and 4 on a 1-4 difficulty scale or laryngoscopy grade >2 on a 1-4 difficulty scale and need for unplanned fiberoptic intubation. Changes in these variables were correlated with weight reduction. Statistical analysis included t test, univariante, and multivariant logistic regression. Five hundred forty-six patients underwent LSG and 83 patients had LBI during the study period. Of those patients, 65 patients had subsequent surgical procedures after the bariatric procedure. Of the 65 patients identified, 62 were eligible. BMI decreased by approximately13 kg/m 2 (p = 0.000) which roughly represents a 30 % reduction between the two surgical procedures. Mallampati class decreased significantly (p = 0.000) while laryngoscopy grade did not (p = 0.419). Our study revealed that a significant reduction in BMI was associated with a significant decrease in Mallampati class. There was no significant decrease in laryngoscopy grade, and there was no case of unplanned fiberoptic intubation.
van den Haak, R F F; Hamans, B C; Zuurmond, K; Verhoeven, B A N; Koning, O H J
2015-10-01
To prospectively quantify radiation dose change in aortoiliac endovascular procedures in the hybrid operating room (OR) for patients and medical staff with a novel X-ray imaging technology (ClarityIQ technology), and to assess whether procedure or fluoroscopy time or dose of iodinated contrast was affected. A prospective study including 138 patients was performed to compare radiation dose before and after installation of a novel X-ray imaging technology. Endovascular aneurysm repair (EVAR) was performed in 37 patients and an endovascular procedure for aortoiliac occlusive disease (AIOD) in 101. Patient radiation dose in air kerma (AK) and dose area product (DAP), patient demographics, and procedural data were recorded. Staff radiation dose was measured with real time personal dosimetry measurements. In both the EVAR and AIOD groups the reference system, ALX (AlluraXper FD20; Philips Healthcare, Best, the Netherlands), was compared with the upgraded X-ray system, CIQ (AlluraClarity FD20; Philips Healthcare). Procedure time, fluoroscopy time, and iodinated contrast dose were recorded. Patient radiation dose reduction in the EVAR group, in median AK, was 56% (ALX = 1,262.5 mGy; CIQ = 556.0 mGy [p < .01]); and in median DAP it was 57% (ALX = 224.4 Gycm(2) and CIQ = 95.8 Gycm(2) [p < .01]). Patient radiation dose reduction in the AIOD group, in median AK, was 76% (ALX = 1,011.0 mGy; CIQ = 248.0 mGy [p < .01]); and in median DAP it was 73% (ALX = 138.1 Gycm(2); CIQ = 38.0 Gycm(2) [p < .01]). Staff dose reduction in the EVAR group was 16% (ALX = 70.1 μSv; CIQ = 59.2 μSv [p = .43]) and in the AIOD group it was 69% (ALX = 96.2 μSv; CIQ = 30.1 μSv [p < .01]). There was no statistically significant difference between patient demographics, procedure time, fluoroscopy time, and iodinated contrast medium use in the two treatment groups before and after installation. A novel X-ray imaging technology in the hybrid OR suite resulted in a significant reduction of patient and staff radiation dose without affecting procedure length, fluoroscopy time, or use of contrast. Copyright © 2015 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.
Hard ceramic coatings: an experimental study on a novel damping treatment
NASA Astrophysics Data System (ADS)
Patsias, Sophoclis; Tassini, Nicola; Stanway, Roger
2004-07-01
This paper describes a novel damping treatment, namely hard ceramic coatings. These materials can be applied on almost any surface (internal or external) of a component. Their effect is the significant reduction of vibration levels and hence the extension of life expectancy of the component. The damping features of air-plasma-sprayed ceramic coatings (for example amplitude dependence, influence of initial amplitude) are discussed and the experimental procedure employed for testing and characterising such materials is also described. This test procedure is based around a custom-developed rig that allows one to measure the damping (internal friction) of specimens at controlled frequencies, strain amplitudes and, if required, various temperatures. A commonly used Thermal Barrier Coating, Yttria Stabilised Zirconia (8%), is used to demonstrate the above mentioned features. The damping effectiveness of this coating is then compared against two established damping treatments: polymer Free Layer Damping (FLD) and Constrained Layer Damping (CLD). The paper discusses the major issues in characterising ceramic damping coatings and their damping effectiveness when compared against the "traditional" approaches. Finally, the paper concludes with suggestions for further research.
Bioreactor performance: a more scientific approach for practice.
Lübbert, A; Bay Jørgensen, S
2001-02-13
In practice, the performance of a biochemical conversion process, i.e. the bioreactor performance, is essentially determined by the benefit/cost ratio. The benefit is generally defined in terms of the amount of the desired product produced and its market price. Cost reduction is the major objective in biochemical engineering. There are two essential engineering approaches to minimizing the cost of creating a particular product in an existing plant. One is to find a control path or operational procedure that optimally uses the dynamics of the process and copes with the many constraints restricting production. The other is to remove or lower the constraints by constructive improvements of the equipment and/or the microorganisms. This paper focuses on the first approach, dealing with optimization of the operational procedure and the measures by which one can ensure that the process adheres to the predetermined path. In practice, feedforward control is the predominant control mode applied. However, as it is frequently inadequate for optimal performance, feedback control may also be employed. Relevant aspects of such performance optimization are discussed.
Preliminary analysis of force-torque measurements for robot-assisted fracture surgery.
Georgilas, Ioannis; Dagnino, Giulio; Tarassoli, Payam; Atkins, Roger; Dogramadzi, Sanja
2015-08-01
Our group at Bristol Robotics Laboratory has been working on a new robotic system for fracture surgery that has been previously reported [1]. The robotic system is being developed for distal femur fractures and features a robot that manipulates the small fracture fragments through small percutaneous incisions and a robot that re-aligns the long bones. The robots controller design relies on accurate and bounded force and position parameters for which we require real surgical data. This paper reports preliminary findings of forces and torques applied during bone and soft tissue manipulation in typical orthopaedic surgery procedures. Using customised orthopaedic surgical tools we have collected data from a range of orthopaedic surgical procedures at Bristol Royal Infirmary, UK. Maximum forces and torques encountered during fracture manipulation which involved proximal femur and soft tissue distraction around it and reduction of neck of femur fractures have been recorded and further analysed in conjunction with accompanying image recordings. Using this data we are establishing a set of technical requirements for creating safe and dynamically stable minimally invasive robot-assisted fracture surgery (RAFS) systems.
System Noise Prediction of the DGEN 380 Turbofan Engine
NASA Technical Reports Server (NTRS)
Berton, Jeffrey J.
2015-01-01
The DGEN 380 is a small, separate-flow, geared turbofan. Its manufacturer, Price Induction, is promoting it for a small twinjet application in the emerging personal light jet market. Smaller, and producing less thrust than other entries in the industry, Price Induction is seeking to apply the engine to a 4- to 5-place twinjet designed to compete in an area currently dominated by propeller-driven airplanes. NASA is considering purchasing a DGEN 380 turbofan to test new propulsion noise reduction technologies in a relevant engine environment. To explore this possibility, NASA and Price Induction have signed a Space Act Agreement and have agreed to cooperate on engine acoustic testing. Static acoustic measurements of the engine were made by NASA researchers during July, 2014 at the Glenn Research Center. In the event that a DGEN turbofan becomes a NASA noise technology research testbed, it is in the interest of NASA to develop procedures to evaluate engine system noise metrics. This report documents the procedures used to project the DGEN static noise measurements to flight conditions and the prediction of system noise of a notional airplane powered by twin DGEN engines.
Lahmar, Aida; Akcan, Tolga; Chekir-Ghedira, Leila; Estévez, Mario
2018-04-01
The present study provides molecular insight into the effect of thymol and carvacrol on the oxidative damage caused to myofibrillar proteins by a hydroxyl-radical generating system (HRGS). An innovative model system was designed, in which gels, prepared with increasing levels of myofibrillar proteins, were oxidized by a HRGS (Fe 3+ /H 2 O 2 , 60 °C and 7 days) in the presence of lipids. The molecular affinity between myofibrillar proteins and both terpenes, as well as their effect on the oxidative stability of the gel systems, were studied using a non-destructive and solvent-free procedure based on fluorescence spectroscopy. Carvacrol displayed more affinity than thymol for establishing chemical interactions with protein residues. Both terpenes exhibited a significant antioxidant potential against the generation of lipid-derived volatile carbonyls and against the formation of protein crosslinking. This procedure may be applied to meat products to assess the effectiveness of a given antioxidant additive without size reduction or sample processing. Copyright © 2018 Elsevier Ltd. All rights reserved.
Rispin, Amy; Farrar, David; Margosches, Elizabeth; Gupta, Kailash; Stitzel, Katherine; Carr, Gregory; Greene, Michael; Meyer, William; McCall, Deborah
2002-01-01
The authors have developed an improved version of the up-and-down procedure (UDP) as one of the replacements for the traditional acute oral toxicity test formerly used by the Organisation for Economic Co-operation and Development member nations to characterize industrial chemicals, pesticides, and their mixtures. This method improves the performance of acute testing for applications that use the median lethal dose (classic LD50) test while achieving significant reductions in animal use. It uses sequential dosing, together with sophisticated computer-assisted computational methods during the execution and calculation phases of the test. Staircase design, a form of sequential test design, can be applied to acute toxicity testing with its binary experimental endpoints (yes/no outcomes). The improved UDP provides a point estimate of the LD50 and approximate confidence intervals in addition to observed toxic signs for the substance tested. It does not provide information about the dose-response curve. Computer simulation was used to test performance of the UDP without the need for additional laboratory validation.
A spectral-finite difference solution of the Navier-Stokes equations in three dimensions
NASA Astrophysics Data System (ADS)
Alfonsi, Giancarlo; Passoni, Giuseppe; Pancaldo, Lea; Zampaglione, Domenico
1998-07-01
A new computational code for the numerical integration of the three-dimensional Navier-Stokes equations in their non-dimensional velocity-pressure formulation is presented. The system of non-linear partial differential equations governing the time-dependent flow of a viscous incompressible fluid in a channel is managed by means of a mixed spectral-finite difference method, in which different numerical techniques are applied: Fourier decomposition is used along the homogeneous directions, second-order Crank-Nicolson algorithms are employed for the spatial derivatives in the direction orthogonal to the solid walls and a fourth-order Runge-Kutta procedure is implemented for both the calculation of the convective term and the time advancement. The pressure problem, cast in the Helmholtz form, is solved with the use of a cyclic reduction procedure. No-slip boundary conditions are used at the walls of the channel and cyclic conditions are imposed at the other boundaries of the computing domain.Results are provided for different values of the Reynolds number at several time steps of integration and are compared with results obtained by other authors.
NASA Astrophysics Data System (ADS)
González-Riancho, P.; Aguirre-Ayerbe, I.; Aniel-Quiroga, I.; Abad, S.; González, M.; Larreynaga, J.; Gavidia, F.; Gutiérrez, O. Q.; Álvarez-Gómez, J. A.; Medina, R.
2013-12-01
Advances in the understanding and prediction of tsunami impacts allow the development of risk reduction strategies for tsunami-prone areas. This paper presents an integral framework for the formulation of tsunami evacuation plans based on tsunami vulnerability assessment and evacuation modelling. This framework considers (i) the hazard aspects (tsunami flooding characteristics and arrival time), (ii) the characteristics of the exposed area (people, shelters and road network), (iii) the current tsunami warning procedures and timing, (iv) the time needed to evacuate the population, and (v) the identification of measures to improve the evacuation process. The proposed methodological framework aims to bridge between risk assessment and risk management in terms of tsunami evacuation, as it allows for an estimation of the degree of evacuation success of specific management options, as well as for the classification and prioritization of the gathered information, in order to formulate an optimal evacuation plan. The framework has been applied to the El Salvador case study, demonstrating its applicability to site-specific response times and population characteristics.
Kotani, Akira; Miyaguchi, Yuji; Tomita, Eiji; Takamura, Kiyoko; Kusu, Fumiyo
2004-03-24
Voltammetric determination of acids by means of the electrochemical reduction of quinone was applied to high-performance liquid chromatography (HPLC) with electrochemical detection (ED) for determining organic acids in fruit wines. A two-channel HPLC-ED system was fabricated by use of an ion-exclusion column and an electrochemical detector with a glassy carbon working electrode. Aqueous solution of 0.1 mM HClO(4) and ethanol containing 2-methyl-1,4-naphthoquinone served as a mobile phase and reagent solution, respectively. Determination of acetic, citric, lactic, malic, succinic, and tartaric acids was made by measuring the peak areas of the flow signals due to the reduction current of quinone caused by the eluted acids. The peak area was found to be linearly related to the acid amount ranging from 0.1 to 40 nmol per 20 microL injection. The present method was characterized by reproducibility with the simple and rapid procedure without derivatization of analytes. The method was shown as an effective means for following acid contents in fruit juices during fermentation with wine yeast.
Analysis and Design of International Emission Trading Markets Applying System Dynamics Techniques
NASA Astrophysics Data System (ADS)
Hu, Bo; Pickl, Stefan
2010-11-01
The design and analysis of international emission trading markets is an important actual challenge. Time-discrete models are needed to understand and optimize these procedures. We give an introduction into this scientific area and present actual modeling approaches. Furthermore, we develop a model which is embedded in a holistic problem solution. Measures for energy efficiency are characterized. The economic time-discrete "cap-and-trade" mechanism is influenced by various underlying anticipatory effects. With a systematic dynamic approach the effects can be examined. First numerical results show that fair international emissions trading can only be conducted with the use of protective export duties. Furthermore a comparatively high price which evokes emission reduction inevitably has an inhibiting effect on economic growth according to our model. As it always has been expected it is not without difficulty to find a balance between economic growth and emission reduction. It can be anticipated using our System Dynamics model simulation that substantial changes must be taken place before international emissions trading markets can contribute to global GHG emissions mitigation.
Green Port / Eco Port Project - Applications and Procedures in Turkey
NASA Astrophysics Data System (ADS)
Akgul, Burak
2017-12-01
As being the heartlands of international trade, sea ports are the junction points of land and sea routes. The growth of global trade has led to the development of number and capacity as well as the service quality of ports. The policies and procedures applied during construction, operation and development of ports under development with environmental considerations scope has evolved in accordance with the needs of global trends. Although maritime transportation provides the most ecofriendly transportation method, the reduction of potential environmental threats and continuous improvement of ports and their vicinity is paramount from environmental concerns with regards to the international environmental standards. In the context of the study, national and international legal regulations governing the control of the environmental impacts of the activity groups causing pollution in Turkey based sea ports were viewed. In addition, the models applied during the measurement and documentation of environmental impacts were investigated. The most important aspects in terms of the effectiveness of the environmental management models are legal regulations. However, the standards applied at the ports without any legal obligation, such as EcoPorts applications, ISO 14001 standard, and the EMAS (Eco-Management and Audit Scheme) were sought in the scope of the study. The boundaries of the study were determined as the EU based Environmental Management Systems and the Green Port/Eco Port Project which is being administered by the Turkish Ministry of Transport, Maritime and Communication. “Marport”, which is Turkey’s first certified Green Port / Eco Port is designated as the experimental study site. In addition, the provisions in the ports of ESPO member countries are approached in order to compare the effectiveness and applicability of Green Port / Eco Port Project.
Enzymatic analysis of α-ketoglutaramate—A biomarker for hyperammonemia
Halámková, Lenka; Mailloux, Shay; Halámek, Jan; Cooper, Arthur J.L.; Katz, Evgeny
2012-01-01
Two enzymatic assays were developed for the analysis of α-ketoglutaramate (KGM)—an important biomarker of hepatic encephalopathy and other hyperammonemic diseases. In both procedures, KGM is first converted to α-ketoglutarate (KTG) via a reaction catalyzed by ω-amidase (AMD). In the first procedure, KTG generated in the AMD reaction initiates a biocatalytic cascade in which the concerted action of alanine transaminase and lactate dehydrogenase results in the oxidation of NADH. In the second procedure, KTG generated from KGM is reductively aminated, with the concomitant oxidation of NADH, in a reaction catalyzed by L-glutamic dehydrogenase. In both assays, the decrease in optical absorbance (λ=340 nm) corresponding to NADH oxidation is used to quantify concentrations of KGM. The two analytical procedures were applied to 50% (v/v) human serum diluted with aqueous solutions containing the assay components and spiked with concentrations of KGM estimated to be present in normal human plasma and in plasma from hyperammonemic patients. Since KTG is the product of AMD-catalyzed hydrolysis of KGM, in a separate study, this compound was used as a surrogate for KGM. Statistical analyses of samples mimicking the concentration of KGM assumed to be present in normal and pathological concentration ranges were performed. Both enzymatic assays for KGM were confirmed to discriminate between the predicted normal and pathophysiological concentrations of the analyte. The present study is the first step toward the development of a clinically useful probe for KGM analysis in biological fluids. PMID:23141304
HIFU procedures at moderate intensities--effect of large blood vessels.
Hariharan, P; Myers, M R; Banerjee, R K
2007-06-21
A three-dimensional computational model is presented for studying the efficacy of high-intensity focused ultrasound (HIFU) procedures targeted near large blood vessels. The analysis applies to procedures performed at intensities below the threshold for cavitation, boiling and highly nonlinear propagation, but high enough to increase tissue temperature a few degrees per second. The model is based upon the linearized KZK equation and the bioheat equation in tissue. In the blood vessel the momentum and energy equations are satisfied. The model is first validated in a tissue phantom, to verify the absence of bubble formation and nonlinear effects. Temperature rise and lesion-volume calculations are then shown for different beam locations and orientations relative to a large vessel. Both single and multiple ablations are considered. Results show that when the vessel is located within about a beam width (few mm) of the ultrasound beam, significant reduction in lesion volume is observed due to blood flow. However, for gaps larger than a beam width, blood flow has no major effect on the lesion formation. Under the clinically representative conditions considered, the lesion volume is reduced about 40% (relative to the no-flow case) when the beam is parallel to the blood vessel, compared to about 20% for a perpendicular orientation. Procedures involving multiple ablation sites are affected less by blood flow than single ablations. The model also suggests that optimally focused transducers can generate lesions that are significantly larger (>2 times) than the ones produced by highly focused beams.
HIFU procedures at moderate intensities—effect of large blood vessels
NASA Astrophysics Data System (ADS)
Hariharan, P.; Myers, M. R.; Banerjee, R. K.
2007-07-01
A three-dimensional computational model is presented for studying the efficacy of high-intensity focused ultrasound (HIFU) procedures targeted near large blood vessels. The analysis applies to procedures performed at intensities below the threshold for cavitation, boiling and highly nonlinear propagation, but high enough to increase tissue temperature a few degrees per second. The model is based upon the linearized KZK equation and the bioheat equation in tissue. In the blood vessel the momentum and energy equations are satisfied. The model is first validated in a tissue phantom, to verify the absence of bubble formation and nonlinear effects. Temperature rise and lesion-volume calculations are then shown for different beam locations and orientations relative to a large vessel. Both single and multiple ablations are considered. Results show that when the vessel is located within about a beam width (few mm) of the ultrasound beam, significant reduction in lesion volume is observed due to blood flow. However, for gaps larger than a beam width, blood flow has no major effect on the lesion formation. Under the clinically representative conditions considered, the lesion volume is reduced about 40% (relative to the no-flow case) when the beam is parallel to the blood vessel, compared to about 20% for a perpendicular orientation. Procedures involving multiple ablation sites are affected less by blood flow than single ablations. The model also suggests that optimally focused transducers can generate lesions that are significantly larger (>2 times) than the ones produced by highly focused beams.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-30
...EPA is finalizing emission standards for new marine diesel engines with per-cylinder displacement at or above 30 liters (called Category 3 marine diesel engines) installed on U.S. vessels. These emission standards are equivalent to those adopted in the amendments to Annex VI to the International Convention for the Prevention of Pollution from Ships (MARPOL Annex VI). The emission standards apply in two stages--near-term standards for newly built engines will apply beginning in 2011; long-term standards requiring an 80 percent reduction in NOX emissions will begin in 2016. We are also finalizing a change to our diesel fuel program that will allow for the production and sale of 1,000 ppm sulfur fuel for use in Category 3 marine vessels. In addition, the new fuel requirements will generally forbid the production and sale of other fuels above 1,000 ppm sulfur for use in most U.S. waters, unless alternative devices, procedures, or compliance methods are used to achieve equivalent emissions reductions. We are adopting further provisions under the Act to Prevent Pollution from Ships, especially to apply the emission standards to engines covered by MARPOL Annex VI that are not covered by the Clean Air Act, and to require that these additional engines use the specified fuels (or equivalents). The final regulations also include technical amendments to our motor vehicle and nonroad engine regulations; many of these changes involve minor adjustments or corrections to our recently finalized rule for new nonroad spark-ignition engines, or adjustment to other regulatory provisions to align with this recent final rule.
Blaivas, Michael; Adhikari, Srikar; Lander, Lina
2011-09-01
Emergency physicians (EPs) are beginning to use ultrasound (US) guidance to perform regional nerve blocks. The primary objective of this study was to compare length of stay (LOS) in patients randomized to US-guided interscalene block or procedural sedation to facilitate reduction of shoulder dislocation in the emergency department (ED). The secondary objectives were to compare one-on-one health care provider time, pain experienced by the patient during reduction, and patient satisfaction between the two groups. This was a prospective, randomized study of patients presenting to the ED with shoulder dislocation. The study was conducted at an academic Level I trauma center ED with an annual census of approximately 80,000. Patients were eligible for the study if they were at least 18 years of age and required reduction of a shoulder dislocation. A convenience sample of patients was randomized to either traditional procedural sedation or US-guided interscalene nerve block. Procedural sedation was performed with etomidate as the sole agent. Interscalene blocks were performed by hospital-credentialed EPs using sterile technique and a SonoSite MicroMaxx US machine with a high-frequency linear array transducer. Categorical variables were evaluated using Fisher's exact test, and continuous variables were analyzed using the Wilcoxon rank sum test. Forty-two patients were enrolled, with 21 patients randomized to each group. The groups were not significantly different with respect to sex or age. The mean (±SD) LOS in the ED was significantly higher in the procedural sedation group (177.3 ± 37.9 min) than in the US-guided interscalene block group (100.3 ± 28.2 minutes; p < 0.0001). The mean (±SD) one-on-one health care provider time was 47.1 (±9.8) minutes for the sedation group and 5 (±0.7) minutes for the US-guided interscalene block group (p < 0.0001). There was no statistically significant difference between the two groups in patient satisfaction or pain experienced during the procedure. There were no significant differences between groups with respect to complications such as hypoxia or hypotension (p = 0.49). In this study, patients undergoing shoulder dislocation reduction using US-guided interscalene block spent less time in the ED and required less one-on-one health care provider time compared to those receiving procedural sedation. There was no difference in pain level or satisfaction when compared to procedural sedation patients. © 2011 by the Society for Academic Emergency Medicine.
Clarke-Pearson, Emily M; Vornovitsky, Michael; Dayan, Joseph H; Samson, William; Sultan, Mark R
2014-01-01
Background Patients having unilateral breast reconstruction often require a second stage procedure on the contralateral breast to improve symmetry. In order to provide immediate symmetry and minimize the frequency and extent of secondary procedures, we began performing simultaneous contralateral balancing operations at the time of initial reconstruction. This study examines the indications, safety, and efficacy of this approach. Methods One-hundred and two consecutive breast reconstructions with simultaneous contralateral balancing procedures were identified. Data included patient age, body mass index (BMI), type of reconstruction and balancing procedure, specimen weight, transfusion requirement, complications and additional surgery under anesthesia. Unpaired t-tests were used to compare BMI, specimen weight and need for non-autologous transfusion. Results Average patient age was 48 years. The majority had autologous tissue-only reconstructions (94%) and the rest prosthesis-based reconstructions (6%). Balancing procedures included reduction mammoplasty (50%), mastopexy (49%), and augmentation mammoplasty (1%). Average BMI was 27 and average reduction specimen was 340 grams. Non-autologous blood transfusion rate was 9%. There was no relationship between BMI or reduction specimen weight and need for transfusion. We performed secondary surgery in 24% of the autologous group and 100% of the prosthesis group. Revision rate for symmetry was 13% in the autologous group and 17% in the prosthesis group. Conclusions Performing balancing at the time of breast reconstruction is safe and most effective in autologous reconstructions, where 87% did not require a second operation for symmetry. PMID:25276646
23 CFR 636.210 - What requirements apply to projects which use the modified design-build procedure?
Code of Federal Regulations, 2011 CFR
2011-04-01
... 23 Highways 1 2011-04-01 2011-04-01 false What requirements apply to projects which use the modified design-build procedure? 636.210 Section 636.210 Highways FEDERAL HIGHWAY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION ENGINEERING AND TRAFFIC OPERATIONS DESIGN-BUILD CONTRACTING Selection Procedures, Award Criteria § 636.210 What requirements...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-29
... spool down, which occurred while applying fuel gravity feed procedure, in response to low pressure... fuel gravity feed procedure, in response to low pressure indications from all fuel boost pumps, in both... while applying fuel gravity feed procedure, in response to low pressure indications from all fuel boost...
Uncertainty propagation from raw data to final results. [ALEX
DOE Office of Scientific and Technical Information (OSTI.GOV)
Larson, N.M.
1985-01-01
Reduction of data from raw numbers (counts per channel) to physically meaningful quantities (such as cross sections) is in itself a complicated procedure. Propagation of experimental uncertainties through that reduction process has sometimes been perceived as even more difficult, if not impossible. At the Oak Ridge Electron Linear Accelerator, a computer code ALEX has been developed to assist in the propagation process. The purpose of ALEX is to carefully and correctly propagate all experimental uncertainties through the entire reduction procedure, yielding the complete covariance matrix for the reduced data, while requiring little additional input from the experimentalist beyond that whichmore » is needed for the data reduction itself. The theoretical method used in ALEX is described, with emphasis on transmission measurements. Application to the natural iron and natural nickel measurements of D.C. Larson is shown.« less
Optical microtopographic inspection of the surface of tooth subjected to stripping reduction
NASA Astrophysics Data System (ADS)
Costa, Manuel F.; Pereira, Pedro B.
2011-05-01
In orthodontics, the decreasing of tooth-size by reducing interproximal enamel surfaces (stripping) of teeth is a common procedure which allows dental alignment with minimal changes in the facial profile and no arch expansion. In order to achieve smooth surfaces, clinicians have been testing various methods and progressively improved this therapeutic technique. In order to evaluate the surface roughness of teeth subject to interproximal reduction through the five most commonly used methods, teeth were inspected by scanning electron microscopy and microtopographically measured using the optical active triangulation based microtopographer MICROTOP.06.MFC. The metrological procedure will be presented as well as the comparative results concluding on the most suitable tooth interproximal reduction method.
Moving base Gravity Gradiometer Survey System (GGSS) program
NASA Astrophysics Data System (ADS)
Pfohl, Louis; Rusnak, Walter; Jircitano, Albert; Grierson, Andrew
1988-04-01
The GGSS program began in early 1983 with the objective of delivering a landmobile and airborne system capable of fast, accurate, and economical gravity gradient surveys of large areas anywhere in the world. The objective included the development and use of post-mission data reduction software to process the survey data into solutions for the gravity disturbance vector components (north, east and vertical). This document describes the GGSS equipment hardware and software, integration and lab test procedures and results, and airborne and land survey procedures and results. Included are discussions on test strategies, post-mission data reduction algorithms, and the data reduction processing experience. Perspectives and conclusions are drawn from the results.
Reduction procedures for accurate analysis of MSX surveillance experiment data
NASA Technical Reports Server (NTRS)
Gaposchkin, E. Mike; Lane, Mark T.; Abbot, Rick I.
1994-01-01
Technical challenges of the Midcourse Space Experiment (MSX) science instruments require careful characterization and calibration of these sensors for analysis of surveillance experiment data. Procedures for reduction of Resident Space Object (RSO) detections will be presented which include refinement and calibration of the metric and radiometric (and photometric) data and calculation of a precise MSX ephemeris. Examples will be given which support the reduction, and these are taken from ground-test data similar in characteristics to the MSX sensors and from the IRAS satellite RSO detections. Examples to demonstrate the calculation of a precise ephemeris will be provided from satellites in similar orbits which are equipped with S-band transponders.
NASA Astrophysics Data System (ADS)
Ritsema, Jeroen; Garnero, Edward; Lay, Thorne
1997-01-01
A new approach for constraining the seismic shear velocity structure above the core-mantle boundary is introduced, whereby SH-SKS differential travel times, amplitude ratios of SV/SKS, and Sdiff waveshapes are simultaneously modeled. This procedure is applied to the lower mantle beneath the central Pacific using da.ta from numerous deep-focus southwest Pacific earthquakes recorded in North America. We analyze 90 broadband and 248 digitized analog recordings for this source-receiver geometry. SH-SKS times are highly variable and up to 10 s larger than standard reference model predictions, indicating the presence of laterally varying low shear velocities in the study area. The travel times, however, do not constrain the depth extent or velocity gradient of the low-velocity region. SV/SKS amplitude ratios and SH waveforms are sensitive to the radial shear velocity profile, and when analyzed simultaneously with SH-SKS times, rnveal up to 3% shear velocity reductions restricted to the lowermost 190±50 km of the mantle. Our preferred model for the central-eastern Pacific region (Ml) has a strong negative gradient (with 0.5% reduction in velocity relative to the preliminary reference Earth model (PREM) at 2700 km depth and 3% reduction at 2891 km depth) and slight velocity reductions from 2000 to 2700 km depth (0-0.5% lower than PREM). Significant small-scale (100-500 km) shear velocity heterogeneity (0.5%-1%) is required to explain scatter in the differential times and amplitude ratios.
40 CFR 60.313 - Performance tests and compliance provisions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... applied (G). (1) An owner or operator shall use the following procedures for any affected facility which... applied (G) during each calendar month for each affected facility, except as provided under § 60.313(c)(2... volume of coating solids applied (G) each calendar month will be determined by the following procedures...
Smallman, Bettina; Dexter, Franklin
2010-03-01
Research in predictive variability of operating room (OR) times has been performed using data from multidisciplinary, tertiary hospitals with mostly adult patients. In this article, we discuss case-duration prediction for children receiving general anesthesia for endoscopy. We critique which of the several types of OR management decisions dependent on accuracy of prediction are relevant to series (lists) of brief pediatric anesthetics. OR information system data were obtained for all children (aged 18 years and younger) undergoing a gastroenterology procedure with an anesthesiologist over 21 months. Summaries of data were used for a qualitative, systematic review of prior studies to learn which apply to brief pediatric cases. Patient arrival times were changed to be based on the statistical method relating actual and scheduled start times (Wachtel and Dexter, Anesth Analg 2007;105:127-40). Even perfect case-duration prediction would not affect whether a brief case was performed on a certain date and/or in a certain OR. There was no evidence of usefulness in calculating the probability that one case would last longer than another or in resequencing cases to influence postanesthesia care unit staffing or patient waiting from scheduled start times. The only decision for which the accuracy of case-duration prediction mattered was for the shortest time that preceding cases in the OR may take. Knowledge of the preceding procedures in the OR was not useful for that purpose because there were hundreds of combinations of preceding procedures and some cases cancelled. Instead, patient ready times were chosen based on 5% lower prediction bounds for ratios of actual to scheduled OR times. The approach was useful based on a 30% reduction in patient waiting times from scheduled start times with corresponding expected reductions in average and peak numbers of patients in the holding area. For brief pediatric OR anesthetics, predictive variability of case durations matters principally to the extent that it affects appropriate patient ready times. Such times should not be chosen by having patients start fasting, arrive, and be ready fixed numbers of hours before their scheduled start times.
Prospective evaluation of CO2 laser-assisted sclerectomy surgery (CLASS) with Mitomycin C.
Cutolo, Carlo Alberto; Bagnis, Alessandro; Scotto, Riccardo; Bonzano, Chiara; Traverso, Carlo Enrico
2018-01-01
Our purpose was to evaluate the clinical safety and efficacy of CO 2 laser-assisted sclerectomy surgery (CLASS) with Mitomycin C (MMC) in open angle glaucoma (OAG). This was a prospective, uncontrolled, interventional case series. All subjects underwent CLASS procedure by a single surgeon. After the dissection of a partial thickness scleral flap, topical MMC 0.2 mg/ml was applied to the sclera and the conjunctiva for 3 min. The CO 2 laser with a beam-manipulating system was used to ablate the scleral tissue and expose the Schlemm's canal area. Primary outcomes: intraocular pressure (IOP) change, number of IOP-lowering medicaments change. Adverse events were evaluated as secondary outcomes. Twenty-one eyes of 21 patients underwent the CLASS procedure. Thirteen were primary OAG (62%), two normal pressure glaucoma (10%), three exfoliative glaucoma (14%) and three others secondary OAG. With a mean (SD) follow-up of 15.3 (5.9) months, the IOP changed from 25.4 (6.7) mmHg at baseline to 10.9 (3.4) mmHg al the last visit. Mean reduction of IOP was -14.5 mmHg (95% CI, -17.7 to -11.2, P < 0.001). The median (IQR) number of IOP-lowering medication decreased from 3 (3-3) at baseline to 1 (0-1) at the last visit (P < 0.001). Visual acuity did not change significantly. Adverse events: five eyes (24%) developed iris adhesion to the filtration area that was successfully managed with office-based procedures. In one case (5%), CLASS was converted to trabeculectomy due to intraoperative perforation of the ablated area. There was one case of hypotony maculopathy successfully treated with placement of additional transconjunctival scleral flap sutures. The CLASS procedure with MMC is clinically safe and effective maintaining a large reduction in IOP and in the number of IOP-lowering medications with a mean follow-up of 15 months. Iris adhesion at the filtrating area warrants further evaluation and possibly reflects the surgeon's learning curve.
López-Gastey, J; Choucri, A; Robidoux, P Y; Sunahara, G I
2000-06-01
An innovative screening procedure has been developed to detect illicit toxic discharges in domestic septic tank sludge hauled to the Montreal Urban Community waste-water treatment plant. This new means of control is based on an integrative approach, using bioassays and chemical analyses. Conservative criteria are applied to detect abnormal toxicity with great reliability while avoiding false positive results. The complementary data obtained from toxicity tests and chemical analyses support the use of this efficient and easy-to-apply procedure. This study assesses the control procedure in which 231 samples were analyzed over a 30-month period. Data clearly demonstrate the deterrent power of an efficient control procedure combined with a public awareness campaign among the carriers. In the first 15 months of application, between January 1996 and March 1997, approximately 30% of the 123 samples analyzed showed abnormal toxicity. Between April 1997 and June 1998, that is, after a public hearing presentation of this procedure, this proportion dropped significantly to approximately 9% based on 108 analyzed samples. The results of a 30-month application of this new control procedure show the superior efficiency of the ecotoxicological approach compared with the previously used chemical control procedure. To be able to apply it effectively and, if necessary, to apply the appropriate coercive measures, ecotoxicological criteria should be included in regulatory guidelines.
Robertson, Dale M.; Schwarz, Gregory E.; Saad, David A.; Alexander, Richard B.
2009-01-01
Excessive loads of nutrients transported by tributary rivers have been linked to hypoxia in the Gulf of Mexico. Management efforts to reduce the hypoxic zone in the Gulf of Mexico and improve the water quality of rivers and streams could benefit from targeting nutrient reductions toward watersheds with the highest nutrient yields delivered to sensitive downstream waters. One challenge is that most conventional watershed modeling approaches (e.g., mechanistic models) used in these management decisions do not consider uncertainties in the predictions of nutrient yields and their downstream delivery. The increasing use of parameter estimation procedures to statistically estimate model coefficients, however, allows uncertainties in these predictions to be reliably estimated. Here, we use a robust bootstrapping procedure applied to the results of a previous application of the hybrid statistical/mechanistic watershed model SPARROW (Spatially Referenced Regression On Watershed attributes) to develop a statistically reliable method for identifying “high priority” areas for management, based on a probabilistic ranking of delivered nutrient yields from watersheds throughout a basin. The method is designed to be used by managers to prioritize watersheds where additional stream monitoring and evaluations of nutrient-reduction strategies could be undertaken. Our ranking procedure incorporates information on the confidence intervals of model predictions and the corresponding watershed rankings of the delivered nutrient yields. From this quantified uncertainty, we estimate the probability that individual watersheds are among a collection of watersheds that have the highest delivered nutrient yields. We illustrate the application of the procedure to 818 eight-digit Hydrologic Unit Code watersheds in the Mississippi/Atchafalaya River basin by identifying 150 watersheds having the highest delivered nutrient yields to the Gulf of Mexico. Highest delivered yields were from watersheds in the Central Mississippi, Ohio, and Lower Mississippi River basins. With 90% confidence, only a few watersheds can be reliably placed into the highest 150 category; however, many more watersheds can be removed from consideration as not belonging to the highest 150 category. Results from this ranking procedure provide robust information on watershed nutrient yields that can benefit management efforts to reduce nutrient loadings to downstream coastal waters, such as the Gulf of Mexico, or to local receiving streams and reservoirs.
Mixed models and reduction method for dynamic analysis of anisotropic shells
NASA Technical Reports Server (NTRS)
Noor, A. K.; Peters, J. M.
1985-01-01
A time-domain computational procedure is presented for predicting the dynamic response of laminated anisotropic shells. The two key elements of the procedure are: (1) use of mixed finite element models having independent interpolation (shape) functions for stress resultants and generalized displacements for the spatial discretization of the shell, with the stress resultants allowed to be discontinuous at interelement boundaries; and (2) use of a dynamic reduction method, with the global approximation vectors consisting of the static solution and an orthogonal set of Lanczos vectors. The dynamic reduction is accomplished by means of successive application of the finite element method and the classical Rayleigh-Ritz technique. The finite element method is first used to generate the global approximation vectors. Then the Rayleigh-Ritz technique is used to generate a reduced system of ordinary differential equations in the amplitudes of these modes. The temporal integration of the reduced differential equations is performed by using an explicit half-station central difference scheme (Leap-frog method). The effectiveness of the proposed procedure is demonstrated by means of a numerical example and its advantages over reduction methods used with the displacement formulation are discussed.
Numerical Procedures for Inlet/Diffuser/Nozzle Flows
NASA Technical Reports Server (NTRS)
Rubin, Stanley G.
1998-01-01
Two primitive variable, pressure based, flux-split, RNS/NS solution procedures for viscous flows are presented. Both methods are uniformly valid across the full Mach number range, Le., from the incompressible limit to high supersonic speeds. The first method is an 'optimized' version of a previously developed global pressure relaxation RNS procedure. Considerable reduction in the number of relatively expensive matrix inversion, and thereby in the computational time, has been achieved with this procedure. CPU times are reduced by a factor of 15 for predominantly elliptic flows (incompressible and low subsonic). The second method is a time-marching, 'linearized' convection RNS/NS procedure. The key to the efficiency of this procedure is the reduction to a single LU inversion at the inflow cross-plane. The remainder of the algorithm simply requires back-substitution with this LU and the corresponding residual vector at any cross-plane location. This method is not time-consistent, but has a convective-type CFL stability limitation. Both formulations are robust and provide accurate solutions for a variety of internal viscous flows to be provided herein.
NASA Astrophysics Data System (ADS)
Lan, B.-R.; Chang, C.-A.; Huang, P.-Y.; Kuo, C.-H.; Ye, Z.-J.; Shen, B.-C.; Chen, B.-K.
2017-11-01
Conservation voltage reduction (CVR) includes peak demand reduction, energy conservation, carbon emission reduction, and electricity bill reduction. This paper analyzes the energy-reduction of Siwei Feeders with applying CVR, which are situated in Penghu region and equipped with smart meters. Furthermore, the applicable voltage reduction range for the feeders will be explored. This study will also investigate how the CVR effect and energy conservation are improved with the voltage control devices integrated. The results of this study can serve as a reference for the Taiwan Power Company to promote and implement voltage reduction and energy conservation techniques. This study is expected to enhance the energy-reduction performance of the Penghu Low Carbon Island Project.
12 CFR 404.10 - Fee waivers or reductions.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 12 Banks and Banking 4 2010-01-01 2010-01-01 false Fee waivers or reductions. 404.10 Section 404.10 Banks and Banking EXPORT-IMPORT BANK OF THE UNITED STATES INFORMATION DISCLOSURE Procedures for Disclosure of Records Under the Freedom of Information Act. § 404.10 Fee waivers or reductions. (a) General...
Strain Gauge Balance Calibration and Data Reduction at NASA Langley Research Center
NASA Technical Reports Server (NTRS)
Ferris, A. T. Judy
1999-01-01
This paper will cover the standard force balance calibration and data reduction techniques used at Langley Research Center. It will cover balance axes definition, balance type, calibration instrumentation, traceability of standards to NIST, calibration loading procedures, balance calibration mathematical model, calibration data reduction techniques, balance accuracy reporting, and calibration frequency.
46 CFR 502.991 - OMB control numbers assigned pursuant to the Paperwork Reduction Act.
Code of Federal Regulations, 2010 CFR
2010-10-01
... PROVISIONS RULES OF PRACTICE AND PROCEDURE Paperwork Reduction Act § 502.991 OMB control numbers assigned pursuant to the Paperwork Reduction Act. This section displays the control numbers assigned to information... comply with the Act, which requires that agencies display a current control number assigned by the...
A Demonstration of Bacterial Reduction of Inorganic Sulfate.
ERIC Educational Resources Information Center
Kinard, W. Frank
1979-01-01
This experiment demonstrates the reduction of inorganic sulfate to sulfide in the pore water of estuarine muds. Procedures involve the incubation of mud samples for varying amounts of time followed by gravimetric determination. (Author/SA)
The Effect of Colonoscopy Reimbursement Reductions on Gastroenterologist Practice Behavior.
McNeill, Matthew B; Chang, Shannon; Sahebjam, Farhad; Goodman, Adam J; Gross, Seth A; Sigal, Samuel H
2016-06-01
The purpose of this study was to assess the effect of decreased colonoscopy reimbursement on gastroenterologist practice behavior, including time to retirement and procedure volume. In 2015, the Centers for Medicare and Medicaid Services proposed reductions in colonoscopy reimbursements. With new initiatives for increased colorectal cancer screening, it is crucial to understand how reimbursement changes could affect these efforts. Randomly selected respondents from the American College of Gastroenterology membership database were surveyed on incremental changes in practice behavior if colonoscopy reimbursement were to decrease by 10, 20, 30, or 40 %. Data were analyzed using both Pearson's Chi-square and analysis of variance. Two thousand and nine gastroenterologists received the survey with a 16.3 % response rate. Procedure volume significantly decreased with degree of reimbursement reductions (p < 0.001). With a 10 % decrease, 72 % of respondents reported no change in the number of colonoscopies performed. With a 20 % decrease, 39 % would decrease their procedure volume, while 21 % of respondents would increase their procedure volume. With a 30 and 40 % decrease, procedure volume decreased by 48 and 50 %, respectively. In terms of retirement, current plans predict a cumulative retirement rate of 29.4 % at 10 years. More than 42 % of respondents plan to retire after 2030. In the 2014-2023 retirement subgroup (N = 74 responses), there was a significant hastening of retirement year at 20 % (p = 0.016), 30 % (p < 0.001), and 40 % (p < 0.001) reimbursement reductions as compared to baseline responses. Decreasing colonoscopy reimbursements may have a significant effect on the effective gastroenterology work force.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Blue, Robert C., E-mail: Robert.c.blue@gmail.com; Lo, Grace C.; Kim, Edward
PurposeA complication of transjugular intrahepatic portosystemic shunts (TIPS) placement is refractory portosystemic encephalopathy (PSE) often requiring TIPS reduction. We report the results of a “sheath control technique” utilizing constraining sheaths during deployment of polytetrafluoroethylene (PTFE)-covered balloon-expandable stents, minimizing stent migration, and providing additional procedural control.MethodsTIPS reduction was performed in 10 consecutive patients for PSE using Atrium iCast covered stents (Atrium Maquet Getinge Group, Germany). Within the indwelling TIPS stent, a 9 mm × 59 mm iCast stent was deployed with 2 cm exposed from the sheath’s distal end and the majority of the stent within the sheath to create the distal hourglass shape. During balloonmore » retraction, the stent was buttressed by the sheath. The proximal portion of the stent was angioplastied to complete the hourglass configuration, and the central portion of the stent was dilated to 5 mm. Demographics, pre- and post-procedure laboratory values, and outcomes were recorded.ResultsTen patients underwent TIPS reduction with 100 % technical success. There was no stent migration during stent deployment. All patients experienced initial improvement of encephalopathy. One patient ultimately required complete TIPS occlusion for refractory PSE, and another developed TIPS occlusion 36 days post-procedure. There was no significant trend toward change in patients’ MELD scores immediately post-procedure or at 30 days (p = 0.46, p = 0.47, respectively).ConclusionTIPS reduction using Atrium iCast PTFE balloon-expandable stents using the “sheath control technique” is safe and effective, and minimizes the risk of stent migration.« less
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 2 2014-04-01 2014-04-01 false Monier-Williams Procedure (With Modifications) for Sulfites in Food, Center for Food Safety and Applied Nutrition, Food and Drug Administration (November 1985...-Williams Procedure (With Modifications) for Sulfites in Food, Center for Food Safety and Applied Nutrition...
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 2 2010-04-01 2010-04-01 false Monier-Williams Procedure (With Modifications) for Sulfites in Food, Center for Food Safety and Applied Nutrition, Food and Drug Administration (November 1985...-Williams Procedure (With Modifications) for Sulfites in Food, Center for Food Safety and Applied Nutrition...
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 2 2012-04-01 2012-04-01 false Monier-Williams Procedure (With Modifications) for Sulfites in Food, Center for Food Safety and Applied Nutrition, Food and Drug Administration (November 1985...-Williams Procedure (With Modifications) for Sulfites in Food, Center for Food Safety and Applied Nutrition...
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 2 2013-04-01 2013-04-01 false Monier-Williams Procedure (With Modifications) for Sulfites in Food, Center for Food Safety and Applied Nutrition, Food and Drug Administration (November 1985...-Williams Procedure (With Modifications) for Sulfites in Food, Center for Food Safety and Applied Nutrition...
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 2 2011-04-01 2011-04-01 false Monier-Williams Procedure (With Modifications) for Sulfites in Food, Center for Food Safety and Applied Nutrition, Food and Drug Administration (November 1985...-Williams Procedure (With Modifications) for Sulfites in Food, Center for Food Safety and Applied Nutrition...
Field trial on the control effect of fipronil bait against German cockroaches
Ree, Han-Il; Lee, In-Yong; Jeon, Soung-Hoo
2006-01-01
A field trial on the control effect of fipronil poison bait against German cockroaches (Blatella germanica) was carried out at different restaurant types in Sinchon, Seoul, Republic of Korea. Monitoring was performed applying food baited traps for 2 days per week. Reduction rates of German cockroaches by applying fipronil baits were 90.9% at Korean restaurants, 96.4% at Chinese restaurants, and 89.4% in beer hall kitchens after 4 weeks of the treatment. Overall average of the reduction rate was 93.9%. As the natural reduction rate at untreated restaurants was 11.5% after 4 weeks, a correction of the average reduction rate by applying the Abbot formula was 93.1%. PMID:16969066
Revision to Planetary Protection Policy for Mars Missions
NASA Technical Reports Server (NTRS)
DeVincenzi, D. L.; Stabekis, P.; Barengoltz, J.; Morrison, David (Technical Monitor)
1994-01-01
Under existing COSPAR policy adopted in 1984, missions to Mars (landers, probes, and some orbiters) are designated as Category IV missions. As such, the procedures for implementing planetary protection requirements could include trajectory biasing, cleanrooms, bioload reduction, sterilization of hardware, and bioshields, i. e. requirements could be similar to Viking. However, in 1992, a U. S. National Academy of Sciences study recommended that controls on forward contamination of Mars be tied to specific mission objectives. The report recommended that Mars landers with life detection instruments be subject to at least Viking-level sterilization procedures for bioload reduction, while spacecraft (including orbiters) without life detection instruments be subject to at least Viking-level pre sterilization procedures for bioload reduction but need not be sterilized. In light of this, it is proposed that the current policy's Category IV missions and their planetary protection requirements be divided into two subcategories as follows: Category IV A, for missions comprising landers and probes without life detection experiments and some orbiters, which will meet a specified bioburden limit for exposed surfaces; Category IV B, for landers and probes with life detection experiments, which will require complete system sterilization. For Category IV A missions, bioburden specifications will be proposed and implementing procedures discussed. A resolution will be proposed to modify the existing COSPAR policy to reflect these changes. Similar specifications, procedures, and resolution for Category IV B missions will be the subject of a later study.
Kasasbeh, Ehab S; Parvez, Babar; Huang, Robert L; Hasselblad, Michele Marie; Glazer, Mark D; Salloum, Joseph G; Cleator, John H; Zhao, David X
2012-11-01
To determine whether radial artery access is associated with a reduction in fluoroscopy time, procedure time, and other procedural variables over a 27-month period during which the radial artery approach was incorporated in a single academic Medical Center. Although previous studies have demonstrated a relationship between increased volume and decreased procedural time, no studies have looked at the integration of radial access over time. Data were collected from consecutive patients who presented to the Vanderbilt University Medical Center cardiac catheterization laboratory from January 1, 2009 to April 1, 2011. Patients who underwent radial access diagnostic catheterization with and without percutaneous coronary intervention were included in this study. A total of 1112 diagnostic cardiac catheterizations through the radial access site were analyzed. High-volume, intermediate-volume, and low-volume operators were grouped based on the percentage of procedures performed through a radial approach. From 2009 to 2011, there was a significant decrease in fluoroscopy time in all operator groups for diagnostic catheterization (P=.035). The high-volume operator group had 1.88 and 3.66 minute reductions in fluoroscopy time compared to the intermediate- and low-volume operator groups, respectively (both P<.001). Likewise, the intermediate-volume operator group had a 1.77 minute improvement compared to the low-volume operator group, but this did not reach statistical significance (P=.102). The improvement in fluoroscopy time and other procedure-related parameters was seen after approximately 25 cases with further improvement after 75 cases. The incorporation of the radial access approach in the cardiac catheterization laboratory led to a decrease in fluoroscopy time for each operator and operator group over the last 3 years. Our data demonstrated that higher-volume radial operators have better procedure, room, and fluoroscopy times when compared to intermediate- and low-volume operators. However, lower-volume operators have a reduction in procedure-related parameters with increased radial cases. Number of procedures needed to become sufficient was demonstrated in the current study.
NASA Astrophysics Data System (ADS)
Li, Zhonghua; Han, Xuesong; Li, Xiaolei; Qin, Xiaofei
2018-04-01
To report the surgical technique and clinical outcomes for the treatment of AAD with atlas assimilation by single-stage posterior reduction and fixation applying intraoperative distraction between occipital and C2 screws. From April 2008 to January 2014, 25 patients underwent single-stage posterior reduction and fixation applying occipital plate, C2 screws and rigid cantilever beam system through intraoperative distraction between occipital and C2 screws. The pre- and postoperative radiologic parameters and JOA score were examined. Follow-up ranged from 6 to 17months in 25 patients. Clinical symptoms improved in 24 patients (96%) and were stable in 1 patient (4%). Radiologic assessment illustrated that complete reduction was achieved in 24 patients and partial reduction (>60%) in 1 patient. Overall, satisfactory decompression and reduction were showed on postoperative MRT and 3D-CT scans of all 25 patients. The single-stage posterior reduction and fixation applying occipital plate, C2 screws and rigid cantilever beam system through intraoperative distraction between occipital and C2 screws for AAD with atlas assimilation is simple, fast, safe and effective. C1 screws insertion for the treatment of AAD with atlas assimilation should be considered.
Theocharidis, Vasileios; Katsaros, Ioannis; Sgouromallis, Emmanouil; Serifis, Nikolaos; Boikou, Vasileios; Tasigiorgos, Sotirios; Kokosis, George; Economopoulos, Konstantinos P
2018-05-01
Smoking is considered to be a significant risk factor for the development of postoperative complications after various surgical procedures, mainly by limiting oxygen delivery to tissues. Evidence on the collective impact of smoking in aesthetic procedure outcomes is scarce. The aim of this study is to evaluate the current evidence on the association between smoking and postoperative outcomes in patients who underwent common elective procedures in plastic surgery. PubMed and Cochrane bibliographical databases were searched from January 1950 to October 2016 for studies reporting on patients who underwent facelift, abdominoplasty, breast reduction and breast reconstruction and for studies with included data on smoking history of treated patients. Fifty-three studies reporting on postoperative complications in tobacco users undergoing facelift, abdominoplasty, breast reduction and reconstruction were identified. Tobacco use is found to significantly increase the total number of postoperative complications as far as abdominoplasty (OR: 5.43; 95% CI = 2.92-10.10), breast reduction (OR: 2.36; 95% CI = 1.64-3.39) and breast reconstruction (OR: 1.91; 95% CI = 1.69-2.17) are concerned. Smoking history does not significantly affect total postoperative complications after facelift procedures (OR: 3.36; 95% CI = 0.92-12.30). Smoking predisposes to surgical site infections, delayed wound healing and skin necrosis in patients undergoing the most common aesthetic procedures in plastic surgery. More rigorous and detailed reporting on the history of tobacco use and surgical outcomes following plastic surgery procedures is needed to better quantify the impact of smoking on the overall postoperative care for this patient population. Copyright © 2018 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Elhawary, Haytham; Oguro, Sota; Tuncali, Kemal; Morrison, Paul R.; Tatli, Servet; Shyn, Paul B.; Silverman, Stuart G.; Hata, Nobuhiko
2010-01-01
Rationale and Objectives To develop non-rigid image registration between pre-procedure contrast enhanced MR images and intra-procedure unenhanced CT images, to enhance tumor visualization and localization during CT-guided liver tumor cryoablation procedures. Materials and Methods After IRB approval, a non-rigid registration (NRR) technique was evaluated with different pre-processing steps and algorithm parameters and compared to a standard rigid registration (RR) approach. The Dice Similarity Coefficient (DSC), Target Registration Error (TRE), 95% Hausdorff distance (HD) and total registration time (minutes) were compared using a two-sided Student’s t-test. The entire registration method was then applied during five CT-guided liver cryoablation cases with the intra-procedural CT data transmitted directly from the CT scanner, with both accuracy and registration time evaluated. Results Selected optimal parameters for registration were section thickness of 5mm, cropping the field of view to 66% of its original size, manual segmentation of the liver, B-spline control grid of 5×5×5 and spatial sampling of 50,000 pixels. Mean 95% HD of 3.3mm (2.5x improvement compared to RR, p<0.05); mean DSC metric of 0.97 (13% increase); and mean TRE of 4.1mm (2.7x reduction) were measured. During the cryoablation procedure registration between the pre-procedure MR and the planning intra-procedure CT took a mean time of 10.6 minutes, the MR to targeting CT image took 4 minutes and MR to monitoring CT took 4.3 minutes. Mean registration accuracy was under 3.4mm. Conclusion Non-rigid registration allowed improved visualization of the tumor during interventional planning, targeting and evaluation of tumor coverage by the ice ball. Future work is focused on reducing segmentation time to make the method more clinically acceptable. PMID:20817574
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-23
... Office of Management and Budget (OMB) for approval under the Paperwork Reduction Act of 1995. DATES... Subjects in 29 CFR Part 1978 Administrative practice and procedure, Employment, Highway safety...
NASA Astrophysics Data System (ADS)
Hsu, Chih-Yu; Huang, Hsuan-Yu; Lee, Lin-Tsang
2010-12-01
The paper propose a new procedure including four stages in order to preserve the desired edges during the image processing of noise reduction. A denoised image can be obtained from a noisy image at the first stage of the procedure. At the second stage, an edge map can be obtained by the Canny edge detector to find the edges of the object contours. Manual modification of an edge map at the third stage is optional to capture all the desired edges of the object contours. At the final stage, a new method called Edge Preserved Inhomogeneous Diffusion Equation (EPIDE) is used to smooth the noisy images or the previously denoised image at the first stage for achieving the edge preservation. The Optical Character Recognition (OCR) results in the experiments show that the proposed procedure has the best recognition result because of the capability of edge preservation.
Lindner, M; Gramer, G; Garbade, S F; Burgard, P
2009-08-01
Tetrahydrobiopterin (BH(4)) cofactor loading is a standard procedure to differentiate defects of BH(4) metabolism from phenylalanine hydroxylase (PAH) deficiency. BH(4) responsiveness also exists in PAH-deficient patients with high residual PAH activity. Unexpectedly, single cases with presumed nil residual PAH activity have been reported to be BH(4) responsive, too. BH(4) responsiveness has been defined either by a >or=30% reduction of blood Phe concentration after a single BH(4) dose or by a decline greater than the individual circadian Phe level variation. Since both methods have methodological disadvantages, we present a model of statistical process control (SPC) to assess BH(4) responsiveness. Phe levels in 17 adult PKU patients of three phenotypic groups off diet were compared without and with three different single oral dosages of BH(4) applied in a double-blind randomized cross-over design. Results are compared for >or=30% reduction and SPC. The effect of BH(4) by >or=30% reduction was significant for groups (p < 0.01) but not for dose (p = 0.064), with no interaction of group with dose (p = 0.24). SPC revealed significant effects for group (p < 0.01) and the interaction for group with dose (p < 0.05) but not for dose alone (p = 0.87). After one or more loadings, seven patients would be judged to be BH(4) responsive either by the 30% criterion or by the SPC model, but only three by both. Results for patients with identical PAH genotype were not very consistent within (for different BH(4) doses) and between the two models. We conclude that a comparison of protein loadings without and with BH(4) combined with a standardized procedure for data analysis and decision would increase the reliability of diagnostic results.
Laser angioplasty for cardiovascular disease
NASA Astrophysics Data System (ADS)
Okada, Masayoshi
2005-07-01
Recently, endovascular interventions such as balloon angioplasty, atherectomy and the stenting method, except for conventional surgery have been clinically employed for the patients with atheromatous plaques of the peripheral- and the coronary arteries, because the number of patients with arteriosclerosis is now increasing in the worldwide. Among these procedures, restenoses after endovascular interventions have been remarkably disclosed in 20-40 % of the patients who underwent percutaneous coronary interventions. Thus, there are still some problems in keeping long-term patency by means of endovascular techniques such as balloon angioplasty and atherectomy (1, 2). For reduction of these problems , laser angioplasty using Argon laser was applied experimentally and clinically. Based on excellent experimental studies, laser was employed for 115 patients with stenotic ,or obstructive lesions occluding more thasn 75 % of the peripheral and the coronary arteries angiographycally.
On the use of imaginary faults in palaeostress analysis
NASA Astrophysics Data System (ADS)
Shan, Yehua; Liang, Xinquan
2017-11-01
The imaginary fault refers to the counterpart of a certain given fault that has a similar expression about the Wallace-Bott hypothesis. It is included to further reduce the feasible fields for the principal stress directions using the right dihedra method. The given fault and its imaginary fault have a similar dip-slip sense under the extensional or compressional regime but, as proved in this paper, a different dip-slip sense under the strike-slip regime. Their relation in dip-slip sense does no change with the rotation of the coordinate system, thus making possible the general use in the reduction of the imaginary faults under any tectonic regime. A procedure for this use is proposed and applied to a real example to demonstrate the feasibility of this method.
The Statistical point of view of Quality: the Lean Six Sigma methodology
Viti, Andrea; Terzi, Alberto
2015-01-01
Six Sigma and Lean are two quality improvement methodologies. The Lean Six Sigma methodology is applicable to repetitive procedures. Therefore, the use of this methodology in the health-care arena has focused mainly on areas of business operations, throughput, and case management and has focused on efficiency outcomes. After the revision of methodology, the paper presents a brief clinical example of the use of Lean Six Sigma as a quality improvement method in the reduction of the complications during and after lobectomies. Using Lean Six Sigma methodology, the multidisciplinary teams could identify multiple modifiable points across the surgical process. These process improvements could be applied to different surgical specialties and could result in a measurement, from statistical point of view, of the surgical quality. PMID:25973253
The Statistical point of view of Quality: the Lean Six Sigma methodology.
Bertolaccini, Luca; Viti, Andrea; Terzi, Alberto
2015-04-01
Six Sigma and Lean are two quality improvement methodologies. The Lean Six Sigma methodology is applicable to repetitive procedures. Therefore, the use of this methodology in the health-care arena has focused mainly on areas of business operations, throughput, and case management and has focused on efficiency outcomes. After the revision of methodology, the paper presents a brief clinical example of the use of Lean Six Sigma as a quality improvement method in the reduction of the complications during and after lobectomies. Using Lean Six Sigma methodology, the multidisciplinary teams could identify multiple modifiable points across the surgical process. These process improvements could be applied to different surgical specialties and could result in a measurement, from statistical point of view, of the surgical quality.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zlotnikov, Michael
We develop a polynomial reduction procedure that transforms any gauge fixed CHY amplitude integrand for n scattering particles into a σ-moduli multivariate polynomial of what we call the standard form. We show that a standard form polynomial must have a specific ladder type monomial structure, which has finite size at any n, with highest multivariate degree given by (n – 3)(n – 4)/2. This set of monomials spans a complete basis for polynomials with rational coefficients in kinematic data on the support of scattering equations. Subsequently, at tree and one-loop level, we employ the global residue theorem to derive amore » prescription that evaluates any CHY amplitude by means of collecting simple residues at infinity only. Furthermore, the prescription is then applied explicitly to some tree and one-loop amplitude examples.« less
Singularities at the contact point of two kissing Neumann balls
NASA Astrophysics Data System (ADS)
Nazarov, Sergey A.; Taskinen, Jari
2018-02-01
We investigate eigenfunctions of the Neumann Laplacian in a bounded domain Ω ⊂Rd, where a cuspidal singularity is caused by a cavity consisting of two touching balls, or discs in the planar case. We prove that the eigenfunctions with all of their derivatives are bounded in Ω ‾, if the dimension d equals 2, but in dimension d ≥ 3 their gradients have a strong singularity O (| x - O|-α), α ∈ (0 , 2 -√{ 2 } ] at the point of tangency O. Our study is based on dimension reduction and other asymptotic procedures, as well as the Kondratiev theory applied to the limit differential equation in the punctured hyperplane R d - 1 ∖ O. We also discuss other shapes producing thinning gaps between touching cavities.
Fast model updating coupling Bayesian inference and PGD model reduction
NASA Astrophysics Data System (ADS)
Rubio, Paul-Baptiste; Louf, François; Chamoin, Ludovic
2018-04-01
The paper focuses on a coupled Bayesian-Proper Generalized Decomposition (PGD) approach for the real-time identification and updating of numerical models. The purpose is to use the most general case of Bayesian inference theory in order to address inverse problems and to deal with different sources of uncertainties (measurement and model errors, stochastic parameters). In order to do so with a reasonable CPU cost, the idea is to replace the direct model called for Monte-Carlo sampling by a PGD reduced model, and in some cases directly compute the probability density functions from the obtained analytical formulation. This procedure is first applied to a welding control example with the updating of a deterministic parameter. In the second application, the identification of a stochastic parameter is studied through a glued assembly example.
Project MAGNET High-level Vector Survey Data Reduction
NASA Technical Reports Server (NTRS)
Coleman, Rachel J.
1992-01-01
Since 1951, the U.S. Navy, under its Project MAGNET program, has been continuously collecting vector aeromagnetic survey data to support the U.S. Defense Mapping Agency's world magnetic and charting program. During this forty-year period, a variety of survey platforms and instrumentation configurations have been used. The current Project MAGNET survey platform is a Navy Orion RP-3D aircraft which has been specially modified and specially equipped with a redundant suite of navigational positioning, attitude, and magnetic sensors. A review of the survey data collection procedures and calibration and editing techniques applied to the data generated by this suite of instrumentation will be presented. Among the topics covered will be the determination of its parameters from the low-level calibration maneuvers flown over geomagnetic observatories.
NASA Astrophysics Data System (ADS)
Kjærgaard, Thomas
2017-01-01
The divide-expand-consolidate resolution of the identity second-order Møller-Plesset perturbation (DEC-RI-MP2) theory method introduced in Baudin et al. [J. Chem. Phys. 144, 054102 (2016)] is significantly improved by introducing the Laplace transform of the orbital energy denominator in order to construct the double amplitudes directly in the local basis. Furthermore, this paper introduces the auxiliary reduction procedure, which reduces the set of the auxiliary functions employed in the individual fragments. The resulting Laplace transformed divide-expand-consolidate resolution of the identity second-order Møller-Plesset perturbation method is applied to the insulin molecule where we obtain a factor 9.5 speedup compared to the DEC-RI-MP2 method.
Salunkhe, Vishal; van der Meer, Pieter F; de Korte, Dirk; Seghatchian, Jerard; Gutiérrez, Laura
2015-02-01
Transfusion-transmitted infections (TTI) have been greatly reduced in numbers due to the strict donor selection and screening procedures, i.e. the availability of technologies to test donors for endemic infections, and routine vigilance of regulatory authorities in every step of the blood supply chain (collection, processing and storage). However, safety improvement is still a matter of concern because infection zero-risk in transfusion medicine is non-existent. Alternatives are required to assure the safety of the transfusion product and to provide a substitution to systematic blood screening tests, especially in less-developed countries or at the war-field. Furthermore, the increasing mobility of the population due to traveling poses a new challenge in the endemic screening tests routinely used, because non-endemic pathogens might emerge in a specific population. Pathogen reduction treatments sum a plethora of active approaches to eliminate or reduce potential threatening pathogen load from blood transfusion products. Despite the success of pathogen reduction treatments applied to plasma products, there is still a long way to develop and deploy pathogen reduction treatments to cellular transfusion products (such as platelets, RBCs or even to whole blood) and there is divergence on its acceptance worldwide. While the use of pathogen reduction treatments in platelets is performed routinely in a fair number of European blood banks, most of these treatments are not (or just) licensed in the USA or elsewhere in the world. The development of pathogen reduction treatments for RBC and whole blood is still in its infancy and under clinical trials. In this review, we discuss the available and emerging pathogen reduction treatments and their advantages and disadvantages. Furthermore, we highlight the importance of characterizing standard transfusion products with current and emerging approaches (OMICS) and clinical outcome, and integrating this information on a database, thinking on the benefits it might bring in the future toward personalized transfusion therapies. Copyright © 2014 Elsevier Ltd. All rights reserved.
18 CFR 11.14 - Procedures for establishing charges without an energy gains investigation.
Code of Federal Regulations, 2010 CFR
2010-04-01
... hydrology or project development, that affect headwater benefits. (2) Any procedures that apply to § 11.17(b)(5) of this subpart will apply to any prospectively fixed charges that are continued under this...
18 CFR 11.14 - Procedures for establishing charges without an energy gains investigation.
Code of Federal Regulations, 2011 CFR
2011-04-01
... hydrology or project development, that affect headwater benefits. (2) Any procedures that apply to § 11.17(b)(5) of this subpart will apply to any prospectively fixed charges that are continued under this...
Procedural-support music therapy in the healthcare setting: a cost-effectiveness analysis.
DeLoach Walworth, Darcy
2005-08-01
This comparative analysis examined the cost-effectiveness of music therapy as a procedural support in the pediatric healthcare setting. Many healthcare organizations are actively attempting to reduce the amount of sedation for pediatric patients undergoing various procedures. Patients receiving music therapy-assisted computerized tomography scans ( n = 57), echocardiograms ( n = 92), and other procedures ( n = 17) were included in the analysis. Results of music therapy-assisted procedures indicate successful elimination of patient sedation, reduction in procedural times, and decrease in the number of staff members present for procedures. Implications for nurses and music therapists in the healthcare setting are discussed.
NASA Astrophysics Data System (ADS)
Szopa, S.; Aumont, B.; Madronich, S.
2005-09-01
The objective of this work was to develop and assess an automatic procedure to generate reduced chemical schemes for the atmospheric photooxidation of volatile organic carbon (VOC) compounds. The procedure is based on (i) the development of a tool for writing the fully explicit schemes for VOC oxidation (see companion paper Aumont et al., 2005), (ii) the application of several commonly used reduction methods to the fully explicit scheme, and (iii) the assessment of resulting errors based on direct comparison between the reduced and full schemes.
The reference scheme included seventy emitted VOCs chosen to be representative of both anthropogenic and biogenic emissions, and their atmospheric degradation chemistry required more than two million reactions among 350000 species. Three methods were applied to reduce the size of the reference chemical scheme: (i) use of operators, based on the redundancy of the reaction sequences involved in the VOC oxidation, (ii) grouping of primary species having similar reactivities into surrogate species and (iii) grouping of some secondary products into surrogate species. The number of species in the final reduced scheme is 147, this being small enough for practical inclusion in current three-dimensional models. Comparisons between the fully explicit and reduced schemes, carried out with a box model for several typical tropospheric conditions, showed that the reduced chemical scheme accurately predicts ozone concentrations and some other aspects of oxidant chemistry for both polluted and clean tropospheric conditions.
Ma, Ching-Hou; Tu, Yuan-Kun; Yeh, Jih-Hsi; Yang, Shih-Chieh; Wu, Chin-Hsien
2011-09-01
The tibial segmental fractures usually follow high-energy trauma and are often associated with many complications. We designed a two-stage protocol for these complex injuries. The aim of this study was to assess the outcome of tibial segmental fractures treated according to this protocol. A prospective series of 25 consecutive segmental tibial fractures were treated using a two-stage procedure. In the first stage, a low-profile locking plate was applied as an external fixator to temporarily immobilize the fractures after anatomic reduction had been achieved followed by soft-tissue reconstruction. The second stage involved definitive internal fixation with a locking plate using a minimally invasive percutaneous plate osteosynthesis technique. The median follow-up was 32 months (range, 20-44 months). All fractures achieved union. The median time for the proximal fracture union was 23 weeks (range, 12-30 weeks) and that for distal fracture union was 27 weeks (range, 12-46 weeks; p = 0.08). Functional results were excellent in 21 patients and good in 4 patients. There were three cases of delayed union of distal fracture. Valgus malunion >5 degrees occurred in two patients, and length discrepancy >1 cm was observed in two patients. Pin tract infection occurred in three patients. Use of the two-stage procedure for treatment of segmental tibial fractures is recommended. Surgeons can achieve good reduction with stable temporary fixation, soft-tissue reconstruction, ease of subsequent definitive fixation, and high union rates. Our patients obtained excellent knee and ankle joint motion, good functional outcomes, and a comfortable clinical course.
Aircraft Piston Engine Exhaust Emission Symposium
NASA Technical Reports Server (NTRS)
1976-01-01
A 2-day symposium on the reduction of exhaust emissions from aircraft piston engines was held on September 14 and 15, 1976, at the Lewis Research Center in Cleveland, Ohio. Papers were presented by both government organizations and the general aviation industry on the status of government contracts, emission measurement problems, data reduction procedures, flight testing, and emission reduction techniques.
Drinking water biofilm cohesiveness changes under chlorination or hydrodynamic stress.
Mathieu, L; Bertrand, I; Abe, Y; Angel, E; Block, J C; Skali-Lami, S; Francius, G
2014-05-15
Attempts at removal of drinking water biofilms rely on various preventive and curative strategies such as nutrient reduction in drinking water, disinfection or water flushing, which have demonstrated limited efficiency. The main reason for these failures is the cohesiveness of the biofilm driven by the physico-chemical properties of its exopolymeric matrix (EPS). Effective cleaning procedures should break up the matrix and/or change the elastic properties of bacterial biofilms. The aim of this study was to evaluate the change in the cohesive strength of two-month-old drinking water biofilms under increasing hydrodynamic shear stress τw (from ∼0.2 to ∼10 Pa) and shock chlorination (applied concentration at T0: 10 mg Cl2/L; 60 min contact time). Biofilm erosion (cell loss per unit surface area) and cohesiveness (changes in the detachment shear stress and cluster volumes measured by atomic force microscopy (AFM)) were studied. When rapidly increasing the hydrodynamic constraint, biofilm removal was found to be dependent on a dual process of erosion and coalescence of the biofilm clusters. Indeed, 56% of the biofilm cells were removed with, concomitantly, a decrease in the number of the 50-300 μm(3) clusters and an increase in the number of the smaller (i.e., <50 μm(3)) and larger (i.e., >600 μm(3)) ones. Moreover, AFM evidenced the strengthening of the biofilm structure along with the doubling of the number of contact points, NC, per cluster volume unit following the hydrodynamic disturbance. This suggests that the compactness of the biofilm exopolymers increases with hydrodynamic stress. Shock chlorination removed cells (-75%) from the biofilm while reducing the volume of biofilm clusters. Oxidation stress resulted in a decrease in the cohesive strength profile of the remaining drinking water biofilms linked to a reduction in the number of contact points within the biofilm network structure in particular for the largest biofilm cluster volumes (>200 μm(3)). Changes in the cohesive strength of drinking water biofilms subsequent to cleaning/disinfection operations call into question the effectiveness of cleaning-in-place procedures. The combined alternating use of oxidation and shear stress sequences needs to be investigated as it could be an important adjunct to improving biofilm removal/reduction procedures. Copyright © 2014 Elsevier Ltd. All rights reserved.
Harm reduction principles for healthcare settings.
Hawk, Mary; Coulter, Robert W S; Egan, James E; Fisk, Stuart; Reuel Friedman, M; Tula, Monique; Kinsky, Suzanne
2017-10-24
Harm reduction refers to interventions aimed at reducing the negative effects of health behaviors without necessarily extinguishing the problematic health behaviors completely. The vast majority of the harm reduction literature focuses on the harms of drug use and on specific harm reduction strategies, such as syringe exchange, rather than on the harm reduction philosophy as a whole. Given that a harm reduction approach can address other risk behaviors that often occur alongside drug use and that harm reduction principles have been applied to harms such as sex work, eating disorders, and tobacco use, a natural evolution of the harm reduction philosophy is to extend it to other health risk behaviors and to a broader healthcare audience. Building on the extant literature, we used data from in-depth qualitative interviews with 23 patients and 17 staff members from an HIV clinic in the USA to describe harm reduction principles for use in healthcare settings. We defined six principles of harm reduction and generalized them for use in healthcare settings with patients beyond those who use illicit substances. The principles include humanism, pragmatism, individualism, autonomy, incrementalism, and accountability without termination. For each of these principles, we present a definition, a description of how healthcare providers can deliver interventions informed by the principle, and examples of how each principle may be applied in the healthcare setting. This paper is one of the firsts to provide a comprehensive set of principles for universal harm reduction as a conceptual approach for healthcare provision. Applying harm reduction principles in healthcare settings may improve clinical care outcomes given that the quality of the provider-patient relationship is known to impact health outcomes and treatment adherence. Harm reduction can be a universal precaution applied to all individuals regardless of their disclosure of negative health behaviors, given that health behaviors are not binary or linear but operate along a continuum based on a variety of individual and social determinants.
Analysis of helicopter noise data using international helicopter noise certification procedures
DOT National Transportation Integrated Search
1986-03-31
This report documents the results of a Federal Aviation Administration (FAA) noise measurement flight test program involving seven helicopters and established noise levels using the basic testing, reduction and analysis procedures specified by the In...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-23
... Management and Budget (OMB) for approval under the Paperwork Reduction Act of 1995. DATES: Comments on the... Federal Register notice. List of Subjects in 29 CFR Part 1982 Administrative practice and procedure...
Principal Component Noise Filtering for NAST-I Radiometric Calibration
NASA Technical Reports Server (NTRS)
Tian, Jialin; Smith, William L., Sr.
2011-01-01
The National Polar-orbiting Operational Environmental Satellite System (NPOESS) Airborne Sounder Testbed- Interferometer (NAST-I) instrument is a high-resolution scanning interferometer that measures emitted thermal radiation between 3.3 and 18 microns. The NAST-I radiometric calibration is achieved using internal blackbody calibration references at ambient and hot temperatures. In this paper, we introduce a refined calibration technique that utilizes a principal component (PC) noise filter to compensate for instrument distortions and artifacts, therefore, further improve the absolute radiometric calibration accuracy. To test the procedure and estimate the PC filter noise performance, we form dependent and independent test samples using odd and even sets of blackbody spectra. To determine the optimal number of eigenvectors, the PC filter algorithm is applied to both dependent and independent blackbody spectra with a varying number of eigenvectors. The optimal number of PCs is selected so that the total root-mean-square (RMS) error is minimized. To estimate the filter noise performance, we examine four different scenarios: apply PC filtering to both dependent and independent datasets, apply PC filtering to dependent calibration data only, apply PC filtering to independent data only, and no PC filters. The independent blackbody radiances are predicted for each case and comparisons are made. The results show significant reduction in noise in the final calibrated radiances with the implementation of the PC filtering algorithm.
Grand Challenges for Disaster Reduction
2005-06-01
6—Promote risk-wise behavior. Develop and apply principles of economics and human behavior to enhance communications, trust, and understand- ing...Challenges for Disaster Reduction Promote Risk-Wise Behavior. Develop and apply principles of economics and human behavior to enhance communications
Reduction of uterine prolapse in a sow by laparotomy.
Raleigh, P J
1977-01-29
In the past, total uterine prolapse in the sow has been regarded as a grave condition because manipulative reposition through the vulva and vagina is extremely difficult, if not impossible, and amputation is merely a salvage procedure with a mortality rate approaching 100 percent. Laparotomy as a means of facilitating reduction of the prolapse in the sow appears to have been overlooked although it is a standard procedure in dogs and cats. This report describes a case of uterine prolapse in a sow successfully treated by laparotomy.
Wing Leading Edge Concepts for Noise Reduction
NASA Technical Reports Server (NTRS)
Shmilovich, Arvin; Yadlin, Yoram; Pitera, David M.
2010-01-01
This study focuses on the development of wing leading edge concepts for noise reduction during high-lift operations, without compromising landing stall speeds, stall characteristics or cruise performance. High-lift geometries, which can be obtained by conventional mechanical systems or morphing structures have been considered. A systematic aerodynamic analysis procedure was used to arrive at several promising configurations. The aerodynamic design of new wing leading edge shapes is obtained from a robust Computational Fluid Dynamics procedure. Acoustic benefits are qualitatively established through the evaluation of the computed flow fields.
Applying multi-criteria decision-making to improve the waste reduction policy in Taiwan.
Su, Jun-Pin; Hung, Ming-Lung; Chao, Chia-Wei; Ma, Hwong-wen
2010-01-01
Over the past two decades, the waste reduction problem has been a major issue in environmental protection. Both recycling and waste reduction policies have become increasingly important. As the complexity of decision-making has increased, it has become evident that more factors must be considered in the development and implementation of policies aimed at resource recycling and waste reduction. There are many studies focused on waste management excluding waste reduction. This study paid more attention to waste reduction. Social, economic, and management aspects of waste treatment policies were considered in this study. Further, a life-cycle assessment model was applied as an evaluation system for the environmental aspect. Results of both quantitative and qualitative analyses on the social, economic, and management aspects were integrated via the Technique for Order Preference by Similarity to Ideal Solution (TOPSIS) method into the comprehensive decision-making support system of multi-criteria decision-making (MCDM). A case study evaluating the waste reduction policy in Taoyuan County is presented to demonstrate the feasibility of this model. In the case study, reinforcement of MSW sorting was shown to be the best practice. The model in this study can be applied to other cities faced with the waste reduction problems.
Estimation of the annual production and composition of C&D Debris in Galicia (Spain).
Martínez Lage, Isabel; Martínez Abella, Fernando; Herrero, Cristina Vázquez; Ordóñez, Juan Luis Pérez
2010-04-01
One of the key aspects that must be taken into consideration within the framework of Sustainable Construction is the management of Construction and Demolition (C&D) Debris. As for other types of waste, specific handling procedures are required to manage C&D Debris; these include reduction, reuse, recycling, and if all other possibilities fail, recovery or disposal. For public planning strategies aimed at the management of C&D Debris to be effective, it is first necessary to have specific knowledge of the type of waste materials generated in a particular region. After verifying that the methods available to determine the production and composition of C&D Debris are limited, this paper presents a procedure to ascertain the production and composition of C&D Debris, in any region. The procedure utilizes data on the surface areas of newly constructed buildings, renovations and demolitions, which are estimated from available data for recent years, as well as information on the quantity of debris generated per surface area in any type of construction site, which is obtained from recently executed constructions or from the ground plans of older buildings. The method proposed here has been applied to Galicia, one of Spain's autonomous communities, for which the quantity and composition of C&D Debris have been estimated for the horizon year 2011. Copyright 2009 Elsevier Ltd. All rights reserved.
Keefe, Douglas H.; Hunter, Lisa L.; Feeney, M. Patrick; Fitzpatrick, Denis F.
2015-01-01
Procedures are described to measure acoustic reflectance and admittance in human adult and infant ears at frequencies from 0.2 to 8 kHz. Transfer functions were measured at ambient pressure in the ear canal, and as down- or up-swept tympanograms. Acoustically estimated ear-canal area was used to calculate ear reflectance, which was parameterized by absorbance and group delay over all frequencies (and pressures), with substantial data reduction for tympanograms. Admittance measured at the probe tip in adults was transformed into an equivalent admittance at the eardrum using a transmission-line model for an ear canal with specified area and ear-canal length. Ear-canal length was estimated from group delay around the frequency above 2 kHz of minimum absorbance. Illustrative measurements in ears with normal function are described for an adult, and two infants at 1 month of age with normal hearing and a conductive hearing loss. The sensitivity of this equivalent eardrum admittance was calculated for varying estimates of area and length. Infant-ear patterns of absorbance peaks aligned in frequency with dips in group delay were explained by a model of resonant canal-wall mobility. Procedures will be applied in a large study of wideband clinical diagnosis and monitoring of middle-ear and cochlear function. PMID:26723319
Upper Eyelid Fractional CO2 Laser Resurfacing With Incisional Blepharoplasty.
Kotlus, Brett S; Schwarcz, Robert M; Nakra, Tanuj
2016-01-01
Laser resurfacing, performed at the same time as blepharoplasty, has most commonly been applied to the lower eyelid skin but can effectively be used on the upper eyelid to reduce rhytidosis and improve skin quality. The authors evaluate the safety and efficacy of this procedure. Fractional CO2 laser resurfacing was performed in conjunction with incisional upper blepharoplasty. The ultrapulsed laser energy was applied to the sub-brow skin, the upper medial canthal skin, and the pretarsal skin in 30 patients. Photos were obtained preoperatively and at 3 months. All patients demonstrated reduction in upper eyelid rhytidosis without any serious complications. Independent rhytidosis grading (0-4) showed a mean improvement of 42%. One patient experienced wound dehiscence that satisfactorily resolved without intervention. Upper eyelid laser resurfacing is effective and can be safely performed at the same time as upper blepharoplasty. This approach reduces or eliminates the need for medial incisions to address medial canthal skin redundancy and rhytidosis and it directly treats upper eyelid wrinkles on residual eyelid and infra-brow skin during blepharoplasty.
Integrating automated support for a software management cycle into the TAME system
NASA Technical Reports Server (NTRS)
Sunazuka, Toshihiko; Basili, Victor R.
1989-01-01
Software managers are interested in the quantitative management of software quality, cost and progress. An integrated software management methodology, which can be applied throughout the software life cycle for any number purposes, is required. The TAME (Tailoring A Measurement Environment) methodology is based on the improvement paradigm and the goal/question/metric (GQM) paradigm. This methodology helps generate a software engineering process and measurement environment based on the project characteristics. The SQMAR (software quality measurement and assurance technology) is a software quality metric system and methodology applied to the development processes. It is based on the feed forward control principle. Quality target setting is carried out before the plan-do-check-action activities are performed. These methodologies are integrated to realize goal oriented measurement, process control and visual management. A metric setting procedure based on the GQM paradigm, a management system called the software management cycle (SMC), and its application to a case study based on NASA/SEL data are discussed. The expected effects of SMC are quality improvement, managerial cost reduction, accumulation and reuse of experience, and a highly visual management reporting system.
Alternatives to animal testing: A review.
Doke, Sonali K; Dhawale, Shashikant C
2015-07-01
The number of animals used in research has increased with the advancement of research and development in medical technology. Every year, millions of experimental animals are used all over the world. The pain, distress and death experienced by the animals during scientific experiments have been a debating issue for a long time. Besides the major concern of ethics, there are few more disadvantages of animal experimentation like requirement of skilled manpower, time consuming protocols and high cost. Various alternatives to animal testing were proposed to overcome the drawbacks associated with animal experiments and avoid the unethical procedures. A strategy of 3 Rs (i.e. reduction, refinement and replacement) is being applied for laboratory use of animals. Different methods and alternative organisms are applied to implement this strategy. These methods provide an alternative means for the drug and chemical testing, up to some levels. A brief account of these alternatives and advantages associated is discussed in this review with examples. An integrated application of these approaches would give an insight into minimum use of animals in scientific experiments.
Alternatives to animal testing: A review
Doke, Sonali K.; Dhawale, Shashikant C.
2013-01-01
The number of animals used in research has increased with the advancement of research and development in medical technology. Every year, millions of experimental animals are used all over the world. The pain, distress and death experienced by the animals during scientific experiments have been a debating issue for a long time. Besides the major concern of ethics, there are few more disadvantages of animal experimentation like requirement of skilled manpower, time consuming protocols and high cost. Various alternatives to animal testing were proposed to overcome the drawbacks associated with animal experiments and avoid the unethical procedures. A strategy of 3 Rs (i.e. reduction, refinement and replacement) is being applied for laboratory use of animals. Different methods and alternative organisms are applied to implement this strategy. These methods provide an alternative means for the drug and chemical testing, up to some levels. A brief account of these alternatives and advantages associated is discussed in this review with examples. An integrated application of these approaches would give an insight into minimum use of animals in scientific experiments. PMID:26106269
Korenblit, Jason; Tholey, Danielle M.; Tolin, Joanna; Loren, David; Kowalski, Thomas; Adler, Douglas G.; Davolos, Julie; Siddiqui, Ali A.
2016-01-01
Background and Objectives: Recent reports have indicated that the time of day may impact the detection rate of abnormal cytology on gynecologic cytology samples. The aim of this study was to determine if procedure time or queue position affected the performance characteristics of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) for diagnosing solid pancreatic malignancies. Patients and Methods: We conducted a retrospective study evaluating patients with solid pancreatic lesions in whom EUS-FNA was performed. Three timing variables were evaluated as surrogate markers for endoscopist fatigue: Procedure start times, morning versus afternoon procedures, and endoscopy queue position. Statistical analyses were performed to determine whether the timing variables predicted performance characteristics of EUS-FNA. Results: We identified 609 patients (mean age: 65.8 years, 52.1% males) with solid pancreatic lesions who underwent EUS-FNA. The sensitivity of EUS-FNA was 100% for procedures that started at 7 AM while cases that started at 4 PM had a sensitivity of 81%. Using start time on a continuous scale, each elapsed hour was associated with a 1.9% decrease in EUS-FNA sensitivity (P = 0.003). Similarly, a 10% reduction in EUS-FNA sensitivity was detected between morning and afternoon procedures (92% vs. 82% respectively, P = 0.0006). A linear regression comparing the procedure start time and diagnostic accuracy revealed a decrease of approximately 1.7% in procedure accuracy for every hour later a procedure was started. A 16% reduction in EUS-FNA accuracy was detected between morning and afternoon procedures (100% vs. 84% respectively, P = 0.0009). When the queue position was assessed, a 2.4% reduction in accuracy was noted for each increase in the queue position (P = 0.013). Conclusion: Sensitivity and diagnostic accuracy of EUS-FNA for solid pancreatic lesions decline with progressively later EUS starting times and increasing numbers of procedures before a given EUS, potentially from endoscopist fatigue and cytotechnologist fatigue. PMID:27080605
NASA Technical Reports Server (NTRS)
Graham, Thomas; Wheeler, Raymond
2017-01-01
Thigmomorphogenesis can be utilized to improve volume utilization efficiency in peppers (Capsicum annum cv. California Wonder), a candidate crop for fresh food production in space. The effect occurred primarily through a reduction in average plant height. Reductions in vegetative growth metrics during the juvenile growth phase (growth leading up to and including early anthesis) were not observed during the mature or fruiting phase, with the notable exception of reduced plant height. Early flower production and fruit set was reduced under MS; however, the total edible biomass was not reduced, with MS plants producing fewer but larger fruits. The overall reduction in plant height due to MS (Mechanical Stimulation) was sufficient to realize theoretical improvements in VUE (Volume Use Efficiency) for large vertical farming systems. The reduced heights observed could improve VUE in single tier spaceflight hardware (e.g., Veggie; Massa 2016 (this issue)) in that crops that would not normally fit in these spaceflight systems may be accommodated if MS can be applied. Although the potential for using MS to induce thigmomorphogenic phenotypes has long been appreciated, it is only recently that the growth systems themselves could take advantage of the modified crop architecture associated with MS. It is with this in mind that renewed attention should be given to developing procedures for environmentally modifying crops for spaceflight applications.
Randomization Procedures Applied to Analysis of Ballistic Data
1991-06-01
test,;;15. NUMBER OF PAGES data analysis; computationally intensive statistics ; randomization tests; permutation tests; 16 nonparametric statistics ...be 0.13. 8 Any reasonable statistical procedure would fail to support the notion of improvement of dynamic over standard indexing based on this data ...AD-A238 389 TECHNICAL REPORT BRL-TR-3245 iBRL RANDOMIZATION PROCEDURES APPLIED TO ANALYSIS OF BALLISTIC DATA MALCOLM S. TAYLOR BARRY A. BODT - JUNE
Wannagat, Severin; Loehr, Lena; Lask, Sebastian; Völk, Katharina; Karaköse, Tamer; Özcelik, Cemil; Mügge, Andreas; Wutzler, Alexander
2018-04-01
Catheter ablation is performed under fluoroscopic guidance. Reduction of radiation dose for patients and staff is emphasized by current recommendations. Previous studies have shown that lower operator experience leads to increased radiation dose. On the other hand, less experienced operators may depend even more on fluoroscopic guidance. Our study aimed to evaluate feasibility and efficacy of a non-fluoroscopic approach in different training levels. From January 2017, a near-zero fluoroscopy approach was established in two centers. Four operators (beginner, 1st year fellow, 2nd year fellow, expert) were instructed to perform the complete procedure with the use of a 3-D mapping system without fluoroscopy. A historical cohort that underwent procedures with fluoroscopy use served as control group. Dose area product (DPA), procedure duration, acute procedural success, and complications were compared between the groups and for each operator. Procedures were performed in 157 patients. The first 100 patients underwent procedures with fluoroscopic guidance, the following 57 procedures were performed with the near-zero fluoroscopy approach. The results show a significant reduction in DPA for all operators immediately after implementation of the near-zero fluoroscopy protocol (control 637 ± 611 μGy/m 2 ; beginner 44.1 ± 79.5 μGy/m 2 , p = 0.002; 1st year fellow 24.3 ± 46.4.5 μGy/m 2 , p = 0.001; 2nd year fellow 130.3 ± 233.3 μGy/m 2 , p = 0.003; expert 9.3 ± 37.4 μGy/m 2 , P < 0.001). Procedure duration, acute success, and complications were not significantly different between the groups. Our results show a 90% reduction of DPA shortly after implementation of a near-zero fluoroscopy approach in interventional electrophysiology even in operators in training.
10 CFR 205.300 - Who shall apply.
Code of Federal Regulations, 2010 CFR
2010-01-01
... OF ENERGY OIL ADMINISTRATIVE PROCEDURES AND SANCTIONS Electric Power System Permits and Reports; Applications; Administrative Procedures and Sanctions Application for Authorization to Transmit Electric Energy to A Foreign Country § 205.300 Who shall apply. (a) An electric utility or other entity subject to...
Maweja, Kasonde; Mukongo, Tshikele; Mutombo, Ilunga
2009-05-30
Cleaning experiments of a copper matte smelting slag from the water-jacket furnace was undertaken by direct reduction in a laboratory-scale electric furnace. The effects of coal-to-slag ratio, w, and the reduction time, t, were considered for two different coal/slag mixing procedures. In the first procedure, metallurgical coal was added to the molten slag, whereas in the second procedure, coal was premixed with the solid slag before charging into the furnace. The recovery of heavy metals (Cu, Co), and the fuming of Pb and Zn were investigated. Contamination of the metal phase by iron and the acidity index of the final slag were analysed as these may impede the economical viability of the process. The lower w value of 2.56% yielded a recovery rate of less than 60% for copper and less than 50% for cobalt, and around 70% for zinc. However, increasing w to 5% allowed the recovery of 70-90% for Cu, Co and Zn simultaneously after 30-60 min reduction of the molten slag. After reduction, the cleaned slags contained only small amounts of copper and cobalt (<0.4 wt%). Fuming of lead and zinc was efficient as the %Pb of the residual slag dropped to levels lower than 0.04% after 30 min of reduction. Ninety percent of the lead was removed from the initial slag and collected in the dusts. The zinc content of the cleaned slags quickly dropped to between 1 and 3 wt% from the initial 8.2% after 30 min reduction for w value of 5 and after 60 min reduction for w value of 2.56. The dusts contained about 60% Zn and 10% Pb. Recovery of lead from fuming of the slag was higher than 90% in all the experimental conditions considered in this study.
40 CFR 63.851 - Regulatory authority review procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 11 2014-07-01 2014-07-01 false Regulatory authority review procedures... PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES (CONTINUED) National Emission Standards for Hazardous Air Pollutants for Primary Aluminum Reduction Plants...
40 CFR 63.851 - Regulatory authority review procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 10 2011-07-01 2011-07-01 false Regulatory authority review procedures... PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES (CONTINUED) National Emission Standards for Hazardous Air Pollutants for Primary Aluminum Reduction Plants...
40 CFR 63.851 - Regulatory authority review procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 11 2013-07-01 2013-07-01 false Regulatory authority review procedures... PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES (CONTINUED) National Emission Standards for Hazardous Air Pollutants for Primary Aluminum Reduction Plants...
40 CFR 63.851 - Regulatory authority review procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 11 2012-07-01 2012-07-01 false Regulatory authority review procedures... PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES (CONTINUED) National Emission Standards for Hazardous Air Pollutants for Primary Aluminum Reduction Plants...
Procedures for Geometric Data Reduction in Solid Log Modelling
Luis G. Occeña; Wenzhen Chen; Daniel L. Schmoldt
1995-01-01
One of the difficulties in solid log modelling is working with huge data sets, such as those that come from computed axial tomographic imaging. Algorithmic procedures are described in this paper that have successfully reduced data without sacrificing modelling integrity.
Code of Federal Regulations, 2010 CFR
2010-01-01
... authority to order use of procedures for access by potential parties to certain sensitive unclassified... authority to order use of procedures for access by potential parties to certain sensitive unclassified... Commission or the presiding officer. (b) If this part does not prescribe a time limit for an action to be...
Anti-Exposure Technology Identification for Mission Specific Operational Requirements
1981-08-08
APPENDIX A- ANTHROPOMETRY MEASUREMENT PROCEDURES A-1 APPENDIX B - MOBILITY AND REACH MEASUREMENT PROCEDURES B-1 APPENDIX C - MOBILITY REDUCTION DATA...Anti-Exposure Configurations Studied 12 IV Garments/Flight Gear Worn With Each Configuration and Donning Sequence 18 V Subject Anthropometry (% ILE...body anthropometry . The following measurements were made according to the procedures described in Appendix A. Weight Stature (Height) Crotch Height
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-14
... required by the Paperwork Reduction Act of 1995, Public Law 104-13 (44 U.S.C. 3506(c)(2)(A)). Currently... Periods of Accounting. DATES: Written comments should be received on or before August 15, 2011 to be... Periods of Accounting. OMB Number: 1545-1786. Revenue Procedure Numbers: Revenue Procedures 2003-79, 2007...
A vertical-energy-thresholding procedure for data reduction with multiple complex curves.
Jung, Uk; Jeong, Myong K; Lu, Jye-Chyi
2006-10-01
Due to the development of sensing and computer technology, measurements of many process variables are available in current manufacturing processes. It is very challenging, however, to process a large amount of information in a limited time in order to make decisions about the health of the processes and products. This paper develops a "preprocessing" procedure for multiple sets of complicated functional data in order to reduce the data size for supporting timely decision analyses. The data type studied has been used for fault detection, root-cause analysis, and quality improvement in such engineering applications as automobile and semiconductor manufacturing and nanomachining processes. The proposed vertical-energy-thresholding (VET) procedure balances the reconstruction error against data-reduction efficiency so that it is effective in capturing key patterns in the multiple data signals. The selected wavelet coefficients are treated as the "reduced-size" data in subsequent analyses for decision making. This enhances the ability of the existing statistical and machine-learning procedures to handle high-dimensional functional data. A few real-life examples demonstrate the effectiveness of our proposed procedure compared to several ad hoc techniques extended from single-curve-based data modeling and denoising procedures.
ERIC Educational Resources Information Center
Levin, Michael E.; Hayes, Steven C.; Waltz, Thomas
2010-01-01
The Implicit Relational Assessment Procedure (IRAP) is a promising tool for measuring implicit cognitions in applied research. However, the need for training and block effects can limit its capacity to assess effects with individual stimuli and participants, both of which are important for applied research. We developed a modified IRAP, the Mixed…
Aptel, Florent; Denis, Philippe; Rouland, Jean-François; Renard, Jean-Paul; Bron, Alain
2016-08-01
To evaluate the efficacy and safety of the ultrasonic circular cyclocoagulation procedure in patients with open-angle glaucoma naïve of previous filtering surgery. Prospective non-comparative interventional clinical study conducted in five French University Hospitals. Thirty eyes of 30 patients with open-angle glaucoma, intra-ocular pressure (IOP) > 21 mmHg and with no previous filtering glaucoma surgeries were sonicated with a probe comprising six piezoelectric transducers. The six transducers were activated with a 6-s exposure time. Complete ophthalmic examinations were performed before the procedure and at 1 day, 1 week, 1, 2, 3, 6 and 12 months after the procedure. Primary outcomes were qualified surgical success (defined as IOP reduction from baseline ≥20% and IOP > 5 mmHg with possible re-intervention and without hypotensive medication adjunction) and complete surgical success (defined as IOP reduction from baseline ≥20%, IOP > 5 mmHg and IOP < 21 mmHg with possible re-intervention and without hypotensive medication adjunction) at the last follow-up visit and vision-threatening complications. Secondary outcomes were mean IOP at each follow-up visit compared with baseline, medication use, complications and re-interventions. Intra-ocular pressure was significantly reduced (p < 0.05) from a mean pre-operative value of 28.2 ± 7.2 mmHg (n = 3.6 hypotensive medications) to 19.6 ± 7.9 mmHg at 12 months (n = 3.1 hypotensive medications and n = 1.1 procedures) (mean IOP reduction of 30%). Qualified success was achieved in 63% of eyes (19/30) (mean IOP reduction of 37% in these eyes) and complete success in 46.7% of eyes (14/30) (mean IOP reduction of 37% in these eyes) at the last follow-up. No major intra- or post-operative complications occurred. The UC(3) procedure seems to be an effective and well-tolerated method to reduce IOP in patients with open-angle glaucoma without previous filtering surgery. © 2015 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Office of Management and Budget (OMB) control numbers assigned under the Paperwork Reduction Act. 11.201 Section 11.201 Aeronautics and Space... PROCEDURES Paperwork Reduction Act Control Numbers § 11.201 Office of Management and Budget (OMB) control...
Life and reliability modeling of bevel gear reductions
NASA Technical Reports Server (NTRS)
Savage, M.; Brikmanis, C. K.; Lewicki, D. G.; Coy, J. J.
1985-01-01
A reliability model is presented for bevel gear reductions with either a single input pinion or dual input pinions of equal size. The dual pinions may or may not have the same power applied for the analysis. The gears may be straddle mounted or supported in a bearing quill. The reliability model is based on the Weibull distribution. The reduction's basic dynamic capacity is defined as the output torque which may be applied for one million output rotations of the bevel gear with a 90 percent probability of reduction survival.
NASA Astrophysics Data System (ADS)
Munuera Saura, Gregorio
The measurement rate of acoustic reduction (R) in an insulating material is determined in special designed enclosures according to UNE EN ISO 140-1 standard. The construction of a testing room that complies with the standards requires a significant financial investment, that too often can not be provided by general machinery manufacturers. The outdoor machines have to be designed considering the noise emission limits established in the European Directive 2000/14, making the installment of insulating materials in enclosures of machines necessary. Suppliers of insulating materials for industrial use does not normally provide the insulating properties of their products, which are often obtained from rock wool, polyethylene, polyurethane, synthetic rubber, etc. It is difficult to test these materials that are characterized by low density surface in a room standardized test procedure that is based on the measurement of sound pressure. The main problem is getting the validation of the measurement when the rate of acoustic reduction is relatively low, as in the case of materials mentioned above. An alternative procedure is proposed in this Doctoral Thesis based on the measurement of sound intensity. The vector nature of this parameter allows just the flow of energy through a given surface to be measured. The validation of the measurement is achieved with the highest degree of accuracy by applying the criteria included in the standard UNE EN ISO 9614. A steel plate 6 mm thick incorporated with a sound source for amplification of a pink noise signal is designed for carrying out the tests. Faced with the source is placed a piece of material to test. The source is connected and the transmitted sound intensity is measured with a probe consisting of two microphones located opposite one another. Previously it has been determined the flow of acoustic energy that impinges on the piece. The difference between the two measures provides directly the rate of acoustic reduction. The main advantage of the described test procedure is that it can be done in a room with normal dimensions and without specific conditioning. The vibroacoustic behaviour of the testing box and its influence on the measures is another important aspect to be considered. A test of modal analysis has been carried out with a steel plate similar to the enclosures of the box. A mathematical model based on the Statistical Energy Analysis SEA has been developed to estimate the paths of energy transmission from the sound source to the point of measurement with the sound intensity probe. The commercial software AUTOSEA2 LT is used. General conclusions regarding the alternative method of measurement and specific ones related to the capacity of insulation of the tested materials have been obtained. As for the general conclusions, the limitations of measuring with the intensity probe at low and high frequencies have been proved, validating measurements with an accuracy of 0.5 dB according to the criteria set forth in the standard UNE EN ISO 9614 Part 3 have been obtained, and a new test procedure for easy determination of the rate of acoustic reduction of an insulating material with low density surface has been established. Finally, the devised procedure allows future developments in the field of vibroacoustics, such as the application of the principle of reciprocity and the determination of acoustic impedance of materials by application of techniques for measuring of acoustics intensity.
Ding, George X; Alaei, Parham; Curran, Bruce; Flynn, Ryan; Gossman, Michael; Mackie, T Rock; Miften, Moyed; Morin, Richard; Xu, X George; Zhu, Timothy C
2018-05-01
With radiotherapy having entered the era of image guidance, or image-guided radiation therapy (IGRT), imaging procedures are routinely performed for patient positioning and target localization. The imaging dose delivered may result in excessive dose to sensitive organs and potentially increase the chance of secondary cancers and, therefore, needs to be managed. This task group was charged with: a) providing an overview on imaging dose, including megavoltage electronic portal imaging (MV EPI), kilovoltage digital radiography (kV DR), Tomotherapy MV-CT, megavoltage cone-beam CT (MV-CBCT) and kilovoltage cone-beam CT (kV-CBCT), and b) providing general guidelines for commissioning dose calculation methods and managing imaging dose to patients. We briefly review the dose to radiotherapy (RT) patients resulting from different image guidance procedures and list typical organ doses resulting from MV and kV image acquisition procedures. We provide recommendations for managing the imaging dose, including different methods for its calculation, and techniques for reducing it. The recommended threshold beyond which imaging dose should be considered in the treatment planning process is 5% of the therapeutic target dose. Although the imaging dose resulting from current kV acquisition procedures is generally below this threshold, the ALARA principle should always be applied in practice. Medical physicists should make radiation oncologists aware of the imaging doses delivered to patients under their care. Balancing ALARA with the requirement for effective target localization requires that imaging dose be managed based on the consideration of weighing risks and benefits to the patient. © 2018 American Association of Physicists in Medicine.
Dados, A; Kartsiouli, E; Chatzimitakos, Th; Papastephanou, C; Stalikas, C D
2014-12-01
A procedure is developed for the analysis of sub-μg L(-1) levels of arsenic, antimony and selenium after preconcentration of their hydrides. The study highlights the capability of an aqueous suspension of a nanometer-sized magnetic ceria, in the presence of iodide, to function as a sorbent for the in situ trapping and preconcentration of the hydrides of certain metalloids. After extraction, the material is magnetically separated from the trapping solution and analyzed. A slurry suspension sampling approach with inductively coupled plasma-optical emission spectrometry (ICP-OES) is employed for measurements, as the quantitative elution of the adsorbed metalloids is not feasible. The whole analytical procedure consists of five steps: (i) pre-reduction of As, Sb and Se, (ii) generation of the hydrides AsH3, SbH3 and SeH2, (iii) in situ collection in the trapping suspension of magnetic ceria, (iv) isolation of the particles by applying a magnetic field, and (v) measurement of As, Sb and Se concentrations using ICP-OES. Under the established experimental conditions, the efficiency of trapping accounted for 94 ± 2%, 89 ± 2% and 98 ± 3% for As, Sb and Se, respectively, signifying the effective implementation of the overall procedure. The applicability of the procedure has been demonstrated by analyzing tap and lake water and a reference material (soft drinking water). The obtained analytical figures of merit were satisfactory for the analysis of the above metalloids in natural waters by ICP-OES. Copyright © 2014 Elsevier B.V. All rights reserved.
Fegelman, Elliott; Knippenberg, Susan; Schwiers, Michael; Stefanidis, Dimitrios; Gersin, Keith S; Scott, John D; Fernandez, Adolfo Z
2017-05-01
Transection of gastric tissue during laparoscopic sleeve gastrectomy (LSG) can be challenging. Reinforcing the staple line may decrease the incidence of issues requiring intervention. The objective of this study was to compare the number of intraoperative surgical interventions for a surgical stapler and reload system with Gripping Surface Technology (GST) to standard reloads in patients who underwent LSG. Patients who underwent elective LSG were enrolled. The study was conducted in two stages. For Stage 1, procedures were performed using a powered stapler and standard reloads. For Stage 2, a reload system with GST was used. The primary endpoint was surgical interventions for bleeding and/or staple line issues during transection of the greater curvature of the stomach. Propensity score matching was applied to create two groups similar in baseline characteristics and risk factors. A total of 111 subjects were enrolled across four centers. Propensity-matched procedures were completed with the standard (n = 38) or GST reloads (n = 38). The mean number of interventions in the standard group was 1.9 (1.29) versus 1.1 (1.45) in the GST group. Nonparametric comparisons were statistically significant, indicating a reduction in the distribution of interventions for GST subjects (P = .0036 for matched pair data). Tissue slippage during transection was low for both groups. Intraoperative leak testing was negative in all procedures, and no procedures were converted to open. Use of the GST stapling system reduces the need for staple line interventions in LSG. Both stapling systems had an acceptable safety profile.
Tanderup, Malene; Reddy, Sunita; Patel, Tulsi; Nielsen, Birgitte Bruun
2015-05-01
To investigate ethical issues in informed consent for decisions regarding embryo transfer and fetal reduction in commercial gestational surrogacy. Mixed methods study employing observations, an interview-guide and semi-structured interviews. Fertility clinics and agencies in Delhi, India, between December 2011 and December 2012. Doctors providing conceptive technologies to commissioning couples and carrying out surrogacy procedures; surrogate mothers; agents functioning as links for surrogacy. Interviews using semi-structured interview guides were carried out among 20 doctors in 18 fertility clinics, five agents from four agencies and 14 surrogate mothers. Surrogate mothers were interviewed both individually and in the presence of doctors and agents. Data on socio-economic context and experiences among and between various actors in the surrogacy process were coded to identify categories of ethical concern. Numerical and grounded theory-oriented analyses were used. Informed consent, number of embryos transferred, fetal reduction, conflict of interest among the involved parties. None of the 14 surrogate mothers were able to explain the risks involved in embryo transfer and fetal reduction. The majority of the doctors took unilateral decisions about embryo transfer and fetal reduction. The commissioning parents were usually only indirectly involved. In the qualitative analysis, difficulties in explaining procedures, autonomy, self-payment of fertility treatment and conflicts of interest were the main themes. Clinical procedural decisions were primarily made by the doctors. Surrogate mothers were not adequately informed. There is a need for regulation on decision-making procedures to safeguard the interests of surrogate mothers. © 2015 Nordic Federation of Societies of Obstetrics and Gynecology.
Salvage reconstruction of failed interposition arthroplasty at the base of the thumb.
Braun, Richard M; Rechnic, Mark; Shah, Kalpit N
2012-12-01
We present an operative procedure designed to revise a failed arthroplasty at the base of the thumb. This report describes a reliable operation that corrects residual instability and malignment which results in thumbs that are weak and painful despite a previous procedure. The operation has also been used as a primary procedure for arthritis of the trapeziometacarpal joint where instability and subluxation was a major component of the problem requiring joint reconstruction. The unique features of this procedure include a reinforced double-thickness tendon graft, a unique tendon anchor, and a fascia lata allograft spacer. Significant functional improvement is anticipated when joint reconstruction provides increased proximal stability. Pinch and grip measurements improve. Pain scores also diminish after the operation. Hand function and patient satisfaction can be substantially improved with revision arthroplasty when the initial operation has failed to provide a thumb that is mobile, stable, and pain free. The technical features of the procedure address reduction of malignment, restoring of anatomic balance, and secure fixation of the proximal apex of the thumb metacarpal which restores thumb reduction position and digital balance.
NASA Technical Reports Server (NTRS)
Miller, C. G., III; Wilder, S. E.
1972-01-01
Data-reduction procedures for determining free stream and post-normal shock kinetic and thermodynamic quantities are derived. These procedures are applicable to imperfect real air flows in thermochemical equilibrium for temperatures to 15 000 K and a range of pressures from 0.25 N/sq m to 1 GN/sq m. Although derived primarily to meet the immediate needs of the 6-inch expansion tube, these procedures are applicable to any supersonic or hypersonic test facility where combinations of three of the following flow parameters are measured in the test section: (1) Stagnation pressure behind normal shock; (2) freestream static pressure; (3) stagnation point heat transfer rate; (4) free stream velocity; (5) stagnation density behind normal shock; and (6) free stream density. Limitations of the nine procedures and uncertainties in calculated flow quantities corresponding to uncertainties in measured input data are discussed. A listing of the computer program is presented, along with a description of the inputs required and a sample of the data printout.
Stoeckel, D.M.; Stelzer, E.A.; Dick, L.K.
2009-01-01
Quantitative PCR (qPCR), applied to complex environmental samples such as water, wastewater, and feces, is susceptible to methodological and sample related biases. In this study, we evaluated two exogenous DNA spike-and-recovery controls as proxies for recovery efficiency of Bacteroidales 16S rDNA gene sequences (AllBac and qHF183) that are used for microbial source tracking (MST) in river water. Two controls-(1) the plant pathogen Pantoea stewartii, carrying the chromosomal target gene cpsD, and (2) Escherichia coli, carrying the plasmid-borne target gene DsRed2-were added to raw water samples immediately prior to concentration and DNA extraction for qPCR. When applied to samples processed in replicate, recovery of each control was positively correlated with the observed concentration of each MST marker. Adjustment of MST marker concentrations according to recovery efficiency reduced variability in replicate analyses when consistent processing and extraction methodologies were applied. Although the effects of this procedure on accuracy could not be tested due to uncertainties in control DNA concentrations, the observed reduction in variability should improve the strength of statistical comparisons. These findings suggest that either of the tested spike-and-recovery controls can be useful to measure efficiency of extraction and recovery in routine laboratory processing. ?? 2009 Elsevier Ltd.
Kede, Maria Luiza F. M.; Correia, Fabio V.; Conceição, Paulo F.; Salles Junior, Sidney F.; Marques, Marcia; Moreira, Josino C.; Pérez, Daniel V.
2014-01-01
The objective of the present study was to investigate the reduction of mobility, availability and toxicity found in soil contaminated with lead (Pb) and cadmium (Cd) from Santo Amaro Municipality, Bahia, Brazil using two combined methods, commonly tested separately according to the literature: metal mobilization with phosphates and phytoextraction. The strategy applied was the treatment with two sources of phosphates (separately and mixed) followed by phytoremediation with vetiver grass (Vetiveria zizanioides (L.)). The treatments applied (in triplicates) were: T1—potassium dihydrogen phosphate (KH2PO4); T2—reactive natural phosphate fertilizer (NRP) and; T3—a mixture 1:1 of KH2PO4 and NRP. After this step, untreated and treated soils were planted with vetiver grass. The extraction procedures and assays applied to contaminated soil before and after the treatments included metal mobility test (TCLP); sequential extraction with BCR method; toxicity assays with Eisenia andrei. The soil-to-plant transfer factors (TF) for Pb and Cd were estimated in all cases. All treatments with phosphates followed by phytoremediation reduced the mobility and availability of Pb and Cd, being KH2PO4 (T1) plus phytoremediation the most effective one. Soil toxicity however, remained high after all treatments. PMID:25386955
Analyzing coastal environments by means of functional data analysis
NASA Astrophysics Data System (ADS)
Sierra, Carlos; Flor-Blanco, Germán; Ordoñez, Celestino; Flor, Germán; Gallego, José R.
2017-07-01
Here we used Functional Data Analysis (FDA) to examine particle-size distributions (PSDs) in a beach/shallow marine sedimentary environment in Gijón Bay (NW Spain). The work involved both Functional Principal Components Analysis (FPCA) and Functional Cluster Analysis (FCA). The grainsize of the sand samples was characterized by means of laser dispersion spectroscopy. Within this framework, FPCA was used as a dimension reduction technique to explore and uncover patterns in grain-size frequency curves. This procedure proved useful to describe variability in the structure of the data set. Moreover, an alternative approach, FCA, was applied to identify clusters and to interpret their spatial distribution. Results obtained with this latter technique were compared with those obtained by means of two vector approaches that combine PCA with CA (Cluster Analysis). The first method, the point density function (PDF), was employed after adapting a log-normal distribution to each PSD and resuming each of the density functions by its mean, sorting, skewness and kurtosis. The second applied a centered-log-ratio (clr) to the original data. PCA was then applied to the transformed data, and finally CA to the retained principal component scores. The study revealed functional data analysis, specifically FPCA and FCA, as a suitable alternative with considerable advantages over traditional vector analysis techniques in sedimentary geology studies.
14 CFR 413.1 - Scope of this part.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Aeronautics and Space COMMERCIAL SPACE TRANSPORTATION, FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION LICENSING LICENSE APPLICATION PROCEDURES § 413.1 Scope of this part. (a) This part explains how to apply for a license or experimental permit. These procedures apply to all applications for issuing a...
Code of Federal Regulations, 2014 CFR
2014-07-01
... ELIGIBILITY FOR INCLUSION IN THE NATIONAL REGISTER OF HISTORIC PLACES § 63.3 Procedures to be applied when the... State Historic Preservation Officer agree that the property is eligible for inclusion in the National...
Code of Federal Regulations, 2012 CFR
2012-07-01
... ELIGIBILITY FOR INCLUSION IN THE NATIONAL REGISTER OF HISTORIC PLACES § 63.3 Procedures to be applied when the... State Historic Preservation Officer agree that the property is eligible for inclusion in the National...
Code of Federal Regulations, 2013 CFR
2013-07-01
... ELIGIBILITY FOR INCLUSION IN THE NATIONAL REGISTER OF HISTORIC PLACES § 63.3 Procedures to be applied when the... State Historic Preservation Officer agree that the property is eligible for inclusion in the National...
Code of Federal Regulations, 2010 CFR
2010-07-01
... ELIGIBILITY FOR INCLUSION IN THE NATIONAL REGISTER OF HISTORIC PLACES § 63.3 Procedures to be applied when the... State Historic Preservation Officer agree that the property is eligible for inclusion in the National...
Code of Federal Regulations, 2011 CFR
2011-07-01
... ELIGIBILITY FOR INCLUSION IN THE NATIONAL REGISTER OF HISTORIC PLACES § 63.3 Procedures to be applied when the... State Historic Preservation Officer agree that the property is eligible for inclusion in the National...
15 CFR 970.300 - Purposes and definitions.
Code of Federal Regulations, 2014 CFR
2014-01-01
... ENVIRONMENTAL DATA SERVICE DEEP SEABED MINING REGULATIONS FOR EXPLORATION LICENSES Procedures for Applications... procedures which the Administrator will apply to applications filed with NOAA covering areas of the deep... the Administrator and a reciprocating state; and (ii) In which the deep seabed areas applied for...
15 CFR 970.300 - Purposes and definitions.
Code of Federal Regulations, 2013 CFR
2013-01-01
... ENVIRONMENTAL DATA SERVICE DEEP SEABED MINING REGULATIONS FOR EXPLORATION LICENSES Procedures for Applications... procedures which the Administrator will apply to applications filed with NOAA covering areas of the deep... the Administrator and a reciprocating state; and (ii) In which the deep seabed areas applied for...
15 CFR 970.300 - Purposes and definitions.
Code of Federal Regulations, 2012 CFR
2012-01-01
... ENVIRONMENTAL DATA SERVICE DEEP SEABED MINING REGULATIONS FOR EXPLORATION LICENSES Procedures for Applications... procedures which the Administrator will apply to applications filed with NOAA covering areas of the deep... the Administrator and a reciprocating state; and (ii) In which the deep seabed areas applied for...
15 CFR 970.300 - Purposes and definitions.
Code of Federal Regulations, 2010 CFR
2010-01-01
... the Administrator and a reciprocating state; and (ii) In which the deep seabed areas applied for... ENVIRONMENTAL DATA SERVICE DEEP SEABED MINING REGULATIONS FOR EXPLORATION LICENSES Procedures for Applications... procedures which the Administrator will apply to applications filed with NOAA covering areas of the deep...
13 CFR 124.1010 - What procedures apply to disadvantaged status protests?
Code of Federal Regulations, 2010 CFR
2010-01-01
... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false What procedures apply to disadvantaged status protests? 124.1010 Section 124.1010 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION 8(a) BUSINESS DEVELOPMENT/SMALL DISADVANTAGED BUSINESS STATUS DETERMINATIONS Eligibility...
Eliminating Preoperative Lymphoscintigraphy in Extremity Melanomas
McGregor, Andrew; Pavri, Sabrina N.; Kim, Samuel; Xu, Xiaolu
2018-01-01
Background: Preoperative lymphoscintigraphy (LSG) is an imaging procedure routinely used to identify the draining nodal basin in melanomas. At our institute, we have traditionally performed preoperative LSG followed by intraoperative LSG for logistical and evaluative reasons. We sought to determine if preoperative LSG could be safely eliminated in the treatment of extremity melanomas, which exhibit consistent and predictable lymphatic drainage patterns. Methods: We reviewed the Yale Melanoma Registry 1308012545 for cutaneous extremity melanomas treated at our institution. From this registry, we calculated the incidence of atypical lymph node drainage patterns outside the axillary and inguinal regions. Based on these data, we eliminated preoperative LSG in 21 cases (8 upper extremities and 13 lower extremities). Additionally, we calculated the potential hospital charge reduction of forgoing preoperative LSG. Results: Upper and lower extremity melanomas treated at our institution exhibited atypical lymph node drainage at a rate of 3.4% and 2.0%, respectively. The sites of atypical drainage were to the epitrochlear and popliteal regions. In all 21 cases where preoperative LSG was eliminated, we were able to correctly identify the sentinel lymph node. The potential hospital charge reduction of forgoing preoperative LSG totaled $2,393. Conclusions: Preoperative LSG can be safely eliminated in the management of upper and lower extremity melanomas. Exceptions may be considered for primary lesions of the posterior calf, ankle, and heel as well as for patients with history of prior surgery or radiation. Forgoing preoperative LSG results in a hospital charge reduction of $2,393 and provides additional benefits to the patient. Ultimately, there is potential for significant charge reduction if applied across health care systems. PMID:29707448
Option pricing: a flexible tool to disseminate shared savings contracts.
Friedberg, Mark W; Buendia, Anthony M; Lauderdale, Katherine E; Hussey, Peter S
2013-08-01
Due to volatility in healthcare costs, shared savings contracts can create systematic financial losses for payers, especially when contracting with smaller providers. To improve the business case for shared savings, we calculated the prices of financial options that payers can "sell" to providers to offset these losses. Using 2009 to 2010 member-level total cost of care data from a large commercial health plan, we calculated option prices by applying a bootstrap simulation procedure. We repeated these simulations for providers of sizes ranging from 500 to 60,000 patients and for shared savings contracts with and without key design features (minimum savings thresholds,bonus caps, cost outlier truncation, and downside risk) and under assumptions of zero, 1%, and 2% real cost reductions due to the shared savings contracts. Assuming no real cost reduction and a 50% shared savings rate, per patient option prices ranged from $225 (3.1% of overall costs) for 500-patient providers to $23 (0.3%) for 60,000-patient providers. Introducing minimum savings thresholds, bonus caps, cost outlier truncation, and downside risk reduced these option prices. Option prices were highly sensitive to the magnitude of real cost reductions. If shared savings contracts cause 2% reductions in total costs, option prices fall to zero for all but the smallest providers. Calculating the prices of financial options that protect payers and providers from downside risk can inject flexibility into shared savings contracts, extend such contracts to smaller providers, and clarify the tradeoffs between different contract designs, potentially speeding the dissemination of shared savings.
[Ultrasonography-guided therapeutic procedures in the neck region].
Brzac, Hrvojka Tomić
2009-12-01
Minimally invasive therapeutic procedures in medicine have become very popular because of the reduced risk compared to classic surgical treatment, speed of recovery, little or no side effects, and frequently lower cost. One of these methods is ultrasonography-guided percutaneous injection of 95% ethanol (PEIT, percutaneous ethanol injection therapy), which is especially suitable for the neck region. Other methods like laser photocoagulation (ILP) or radiofrequency ablation (RFA) are more aggressive and expensive. The procedure of sterile 95% ethanol injecting is performed on an outpatient basis, without preparation. A specific amount of alcohol is injected into the lesion using a thin spinal needle, under ultrasonography guidance. The amount of alcohol depends on the size of the lesion. Complications are rare and the procedure can be repeated several times. PEIT is used in the treatment of parathyroid glands, especially secondary hyperparathyroidism, thyroid nodules (toxic adenoma, goiters and cysts), other cysts on the neck, and cervical metastases of thyroid cancer. Direct ethanol injection into the tissue causes cellular dehydration and protein denaturation, followed by the development of necrosis, fibrosis, and thrombosis of the small blood vessels. In this way, reduction or disappearance of the nodes can be achieved, along with functional normalization (for parathyroid glands and toxic adenoma), with longer or shorter disease remission or complete recovery. Today, PEIT is mostly used in dialyzed patients with secondary hyperparathyroidism. The treatment gives best results in combination with vitamin D analogs, if 1-2 parathyroid glands are enlarged, and for residual parathyroid gland after parathyroidectomy. A success rate of 50%-70% has been reported, depending on the number of enlarged parathyroid glands. Therapeutic effect is manifested in the size reduction or complete fibrozation of the gland, reduction or disappearance of vascularization, and a decrease in the parathormone level. PEIT produced best results in cysts (thyroid cysts, parathyroid cysts or other cysts on the neck), and can replace surgery. In most cases, results are achieved after the first injection. Volume reduction is between 50% and 95%, depending on the size and content of the cyst (clear, colloidal, or hemorrhagic) and presence of solid tissue. Therapy for toxic and autonomous thyroid adenoma and toxic nodular goiter by ethanol injection is accepted as one of the methods for treating patients that refuse radiation therapy or surgery. The goals of the treatment are nodal size reduction, normalization of thyroid hormones and TSH, and an improved subjective condition of the patient. Complete cure has been achieved in more than 75% of patients. Post-therapeutic development of hypothyroidism is extremely rare. The treatment can also be used for non-toxic goiter, especially those with cystic changes. PEIT is also recommended for the treatment of thyroid cancer neck metastases as an alternative procedure in patients at a high risk of reoperation, those that refuse surgery, and those with radioiodine-negative metastasis. The results of PEIT show significant reduction in nodal size or complete disappearance of the node in more than 70% of patients, with a decrease in serum thyroglobulin, except for patients with distant metastases. The procedure can be repeated until the desired effect is achieved, and is well tolerated by patients. Therapeutic procedures under ultrasonography guidance are becoming ever more important in medical protocols. In the head and neck region, PEIT is the most widely used method because of a number of advantages. The simplicity of the procedure, relatively few side effects, low cost, outpatient treatment and good results make this method preferable to other, invasive therapeutic procedures.
Ulrich, G.A.; Krumholz, L.R.; Suflita, J.M.
1997-01-01
A simplified passive extraction procedure for quantifying reduced inorganic sulfur compounds from sediments and water is presented. This method may also be used for the estimation of sulfate reduction rates. Efficient extraction of FeS, FeS(inf2), and S(sup2-) was obtained with this procedure; however, the efficiency for S(sup0) depended on the form that was tested. Passive extraction can be used with samples containing up to 20 mg of reduced sulfur. We demonstrated the utility of this technique in a determination of both sulfate reduction rates and reduced inorganic sulfur pools in marine and freshwater sediments. A side-by-side comparison of the passive extraction method with the established single-step distillation technique yielded comparable results with a fraction of the effort.
Behavioral Treatment of Children's Fears and Phobias: A Review.
ERIC Educational Resources Information Center
Morris, Richard J.; Kratochwill, Thomas R.
1985-01-01
An overview of the behaviorally-oriented fear reduction methods for children is presented. Systematic desensitization and related procedures, flooding-related therapies, contingency management approaches, modeling procedures, and self-control methods are discussed after reviewing normative and prevalence data regarding children's fears. Research…
Massed Group Desensitization in Reduction of Test-Anxiety
ERIC Educational Resources Information Center
Dawley, Harold H., Jr.; Wenrich, W. W.
1973-01-01
The results of this study of two groups of nursing students, one administered desensitization sessions, the other not, agree with earlier studies which indicate that massed group desensitization is an efficient and efficacious procedure for the reduction of anxiety-based disorders. (Author/KM)
Elia, Nadia; von Elm, Erik; Chatagner, Alexandra; Pöpping, Daniel M; Tramèr, Martin R
2016-01-01
Objectives To study whether systematic reviewers apply procedures to counter-balance some common forms of research malpractice such as not publishing completed research, duplicate publications, or selective reporting of outcomes, and to see whether they identify and report misconduct. Design Cross-sectional analysis of systematic reviews and survey of their authors. Participants 118 systematic reviews published in four journals (Ann Int Med, BMJ, JAMA, Lancet), and the Cochrane Library, in 2013. Main outcomes and measures Number (%) of reviews that applied procedures to reduce the impact of: (1) publication bias (through searching of unpublished trials), (2) selective outcome reporting (by contacting the authors of the original studies), (3) duplicate publications, (4) sponsors’ and (5) authors’ conflicts of interest, on the conclusions of the review, and (6) looked for ethical approval of the studies. Number (%) of reviewers who suspected misconduct are reported. The procedures applied were compared across journals. Results 80 (68%) reviewers confirmed their data. 59 (50%) reviews applied three or more procedures; 11 (9%) applied none. Unpublished trials were searched in 79 (66%) reviews. Authors of original studies were contacted in 73 (62%). Duplicate publications were searched in 81 (69%). 27 reviews (23%) reported sponsors of the included studies; 6 (5%) analysed their impact on the conclusions of the review. Five reviews (4%) looked at conflicts of interest of study authors; none of them analysed their impact. Three reviews (2.5%) looked at ethical approval of the studies. Seven reviews (6%) suspected misconduct; only 2 (2%) reported it explicitly. Procedures applied differed across the journals. Conclusions Only half of the systematic reviews applied three or more of the six procedures examined. Sponsors, conflicts of interest of authors and ethical approval remain overlooked. Research misconduct is sometimes identified, but rarely reported. Guidance on when, and how, to report suspected misconduct is needed. PMID:26936908
Germano, Joseph J; Day, Gina; Gregorious, David; Natarajan, Venkataraman; Cohen, Todd
2005-09-01
The purpose of this study was to evaluate a novel disposable lead-free radiation protection drape for decreasing radiation scatter during electrophysiology procedures. In recent years, there has been an exponential increase in the number of electrophysiology (EP) procedures exposing patients, operators and laboratory staff to higher radiation doses. The RADPAD was positioned slightly lateral to the incision site for pectoral device implants and superior to the femoral vein during electrophysiology studies. Each patient served as their own control and dosimetric measurements were obtained at the examiner's elbow and hand. Radiation badge readings for the operator were obtained three months prior to RADPAD use and three months after introduction. Radiation dosimetry was obtained in twenty patients: 7 electrophysiology studies, 6 pacemakers, 5 catheter ablations, and 2 implantable cardioverter-defibrillators. Eleven women and nine men with a mean age of 63 +/- 4 years had an average fluoroscopy time of 2.5 +/- 0.42 minutes per case. Mean dosimetric measurements at the hand were reduced from 141.38 +/- 24.67 to 48.63 +/- 9.02 milliroentgen (mR) per hour using the protective drape (63% reduction; p < 0.0001). Measurements at the elbow were reduced from 78.78 +/- 7.95 mR per hour to 34.50 +/- 4.18 mR per hour using the drape (55% reduction; p < 0.0001). Badge readings for three months prior to drape introduction averaged 2.45 mR per procedure versus 1.54 mR per procedure for 3 months post-initiation (37% reduction). The use of a novel radiation protection surgical drape can significantly reduce scatter radiation exposure to staff and operators during a variety of EP procedures.
Rajan, Prashant V; Qudsi, Rameez A; Dyer, George S M; Losina, Elena
2018-02-07
There is no consensus on the optimal fixation method for patients who require a surgical procedure for distal radial fractures. We used cost-effectiveness analyses to determine which of 3 modalities offers the best value: closed reduction and percutaneous pinning, open reduction and internal fixation, or external fixation. We developed a Markov model that projected short-term and long-term health benefits and costs in patients undergoing a surgical procedure for a distal radial fracture. Simulations began at the patient age of 50 years and were run over the patient's lifetime. The analysis was conducted from health-care payer and societal perspectives. We estimated transition probabilities and quality-of-life values from the literature and determined costs from Medicare reimbursement schedules in 2016 U.S. dollars. Suboptimal postoperative outcomes were determined by rates of reduction loss (4% for closed reduction and percutaneous pinning, 1% for open reduction and internal fixation, and 11% for external fixation) and rates of orthopaedic complications. Procedural costs were $7,638 for closed reduction and percutaneous pinning, $10,170 for open reduction and internal fixation, and $9,886 for external fixation. Outputs were total costs and quality-adjusted life-years (QALYs), discounted at 3% per year. We considered willingness-to-pay thresholds of $50,000 and $100,000. We conducted deterministic and probabilistic sensitivity analyses to evaluate the impact of data uncertainty. From the health-care payer perspective, closed reduction and percutaneous pinning dominated (i.e., produced greater QALYs at lower costs than) open reduction and internal fixation and dominated external fixation. From the societal perspective, the incremental cost-effectiveness ratio for closed reduction and percutaneous pinning compared with open reduction and internal fixation was $21,058 per QALY and external fixation was dominated. In probabilistic sensitivity analysis, open reduction and internal fixation was cost-effective roughly 50% of the time compared with roughly 45% for closed reduction and percutaneous pinning. When considering data uncertainty, there is only a 5% to 10% difference in the frequency of probability combinations that find open reduction and internal fixation to be more cost-effective. The current degree of uncertainty in the data produces difficulty in distinguishing either strategy as being more cost-effective overall and thus it may be left to surgeon and patient shared decision-making. Economic Level III. See Instructions for Authors for a complete description of levels of evidence.
14 CFR 91.1017 - Amending program manager's management specifications.
Code of Federal Regulations, 2013 CFR
2013-01-01
... management specifications, the following procedure applies: (1) The Flight Standards District Office that... filed within 30 days, the procedures of paragraph (c) of this section apply. (e) If the Flight Standards... TRANSPORTATION (CONTINUED) AIR TRAFFIC AND GENERAL OPERATING RULES GENERAL OPERATING AND FLIGHT RULES Fractional...
14 CFR 91.1017 - Amending program manager's management specifications.
Code of Federal Regulations, 2011 CFR
2011-01-01
... management specifications, the following procedure applies: (1) The Flight Standards District Office that... filed within 30 days, the procedures of paragraph (c) of this section apply. (e) If the Flight Standards... TRANSPORTATION (CONTINUED) AIR TRAFFIC AND GENERAL OPERATING RULES GENERAL OPERATING AND FLIGHT RULES Fractional...
19 CFR 201.21 - Availability of specific records.
Code of Federal Regulations, 2011 CFR
2011-04-01
... not a party. (1) The procedure specified in this section will apply to all demands directed to... employees' official duties. These procedures will also apply to demands directed to former employees if the demands seek nonpublic materials or information acquired during Commission employment. The provisions of...
Fukuda, Atsushi; Fukiage, Kenichi; Futami, Tohru; Miyati, Tosiaki
2016-06-01
The aim of this study was to first develop and use 1.0 s ultrafast magnetic resonance imaging (MRI) to confirm the location of the femoral head in non-sedated infants with developmental dysplasia of the hip (DDH) after reduction with spica cast application in clinical settings. The ultrafast acquisition was achieved by employing a balanced steady-state free precession sequence and immobilizing the patient with dedicated sandbags. On completion of the ultrafast MRI study, all infants were sedated for conventional MRI scanning. Two orthopaedic surgeons retrospectively evaluated the image quality, result of the reduction and total MRI study time (including patient immobilization, coil setup, and scanning) in 14 DDHs of 13 infants (one with bilateral DDHs). Both reviewers stated that there were no motion artefacts for non-sedated infants during the ultrafast MRI and that the quality of both the ultrafast and conventional MRI images were acceptable to assess the femoral head location. Assessment of the reduction procedure resulted in two hips being categorized as 'incomplete reduction' requiring a re-reduction procedure. The total study time of ultrafast and conventional MRI was 6 ± 1 min and 14 ± 3 min, respectively (P < 0.001). No complications due to sedation, such as hypoxia, were reported. The average sedation waiting time was 1 h 25 min ± 34 min. The ultrafast MRI procedure reported here can be readily employed to confirm the location of the femoral head in infants with DDHs, without the use of any sedation.
Hidalgo, Francisco; Mesa, Dolores; Ruiz, Martín; Delgado, Mónica; Rodríguez, Sara; Pardo, Laura; Pan, Manuel; López, Amador; Romero, Miguel A; Suárez de Lezo, José
2016-11-01
The percutaneous mitral valve repair procedure (MitraClip) appears to reduce mitral annulus diameter in patients with functional mitral regurgitation, but the relationship between this and regurgitation severity has not been demonstrated. The aim of this study was to determine the effect of mitral annulus remodeling on the reduction of mitral regurgitation in patients with functional etiology. The study included all patients with functional mitral regurgitation treated with MitraClip at our hospital until January 2015. Echocardiogram (iE33 model, Philips) was performed in all patients immediately after device positioning. Changes in the mitral annulus correlated with mitral regurgitation severity, as assessed using the effective regurgitant orifice area. The study included 23 patients (age, 65±14 years; 74% men; left ventricular ejection fraction, 31%±13%; systolic pulmonary artery pressure, 47±10 mmHg). After the procedure, the regurgitant orifice area decreased by 0.30 cm 2 ±0.04 cm 2 (P<.0005), from a baseline of 0.49 cm 2 ±0.09 cm 2 . Anteroposterior diameter decreased by 3.14 mm±1.01 mm (P<.0005) from a baseline of 28.27 mm±4.9 mm, with no changes in the intercommissural diameter (0.50 mm±0.91 mm vs 40.68 mm±4.7 mm; P=.26). A significant association was seen between anteroposterior diameter reduction and regurgitant orifice area reduction (r=.49; P=.020). In patients with functional mitral regurgitation, the MitraClip device produces an immediate reduction in the anteroposterior diameter. This remodeling may be related to the reduction in mitral regurgitation. Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.
Perronne, Rémi; Goldringer, Isabelle
2018-04-01
We present and highlight a partitioning procedure based on the Rao quadratic entropy index to assess temporal in situ inter-annual varietal and genetic changes of crop diversity. For decades, Western-European agroecosystems have undergone profound changes, among which a reduction of crop genetic diversity. These changes have been highlighted in numerous studies, but no unified partitioning procedure has been proposed to compute the inter-annual variability in both varietal and genetic diversity. To fill this gap, we tested, adjusted and applied a partitioning procedure based on the Rao quadratic entropy index that made possible to describe the different components of crop diversity as well as to account for the relative acreages of varieties. To emphasize the relevance of this procedure, we relied on a case study focusing on the temporal evolution of bread wheat diversity in France over the period 1981-2006 at both national and district scales. At the national scale, we highlighted a decrease of the weighted genetic replacement indicating that varieties sown in the most recent years were more genetically similar than older ones. At the district scale, we highlighted sudden changes in weighted genetic replacement in some agricultural regions that could be due to fast shifts of successive leading varieties over time. Other regions presented a relatively continuous increase of genetic similarity over time, potentially due to the coexistence of a larger number of co-leading varieties that got closer genetically. Based on the partitioning procedure, we argue that a tendency of in situ genetic homogenization could be compared to some of its potential causes, such as a decrease in the speed of replacement or an increase in between-variety genetic similarity over time.
Martins, Rui; Oliveira, Paulo Eduardo; Schmitt, Aurore
2012-06-10
We discuss here the estimation of age at death from two indicators (pubic symphysis and the sacro-pelvic surface of the ilium) based on four different osteological series from Portugal, Great-Britain, South Africa or USA (European origin). These samples and the scoring system of the two indicators were used by Schmitt et al. (2002), applying the methodology proposed by Lucy et al. (1996). In the present work, the same data was processed using a modification of the empirical method proposed by Lucy et al. (2002). The various probability distributions are estimated from training data by using kernel density procedures and Jackknife methodology. Bayes's theorem is then used to produce the posterior distribution from which point and interval estimates may be made. This statistical approach reduces the bias of the estimates to less than 70% of what was obtained by the initial method. This reduction going up to 52% if knowledge of sex of the individual is available, and produces an age for all the individuals that improves age at death assessment. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Quasi-Monte Carlo Methods Applied to Tau-Leaping in Stochastic Biological Systems.
Beentjes, Casper H L; Baker, Ruth E
2018-05-25
Quasi-Monte Carlo methods have proven to be effective extensions of traditional Monte Carlo methods in, amongst others, problems of quadrature and the sample path simulation of stochastic differential equations. By replacing the random number input stream in a simulation procedure by a low-discrepancy number input stream, variance reductions of several orders have been observed in financial applications. Analysis of stochastic effects in well-mixed chemical reaction networks often relies on sample path simulation using Monte Carlo methods, even though these methods suffer from typical slow [Formula: see text] convergence rates as a function of the number of sample paths N. This paper investigates the combination of (randomised) quasi-Monte Carlo methods with an efficient sample path simulation procedure, namely [Formula: see text]-leaping. We show that this combination is often more effective than traditional Monte Carlo simulation in terms of the decay of statistical errors. The observed convergence rate behaviour is, however, non-trivial due to the discrete nature of the models of chemical reactions. We explain how this affects the performance of quasi-Monte Carlo methods by looking at a test problem in standard quadrature.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 4 2014-01-01 2014-01-01 false Procedure for appeal of denial of requests for board records and denial of requests for fee waiver or reduction. 1703.109 Section 1703.109 Energy DEFENSE NUCLEAR FACILITIES SAFETY BOARD PUBLIC INFORMATION AND REQUESTS § 1703.109 Procedure for appeal of denial...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 4 2012-01-01 2012-01-01 false Procedure for appeal of denial of requests for board records and denial of requests for fee waiver or reduction. 1703.109 Section 1703.109 Energy DEFENSE NUCLEAR FACILITIES SAFETY BOARD PUBLIC INFORMATION AND REQUESTS § 1703.109 Procedure for appeal of denial...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 4 2011-01-01 2011-01-01 false Procedure for appeal of denial of requests for board records and denial of requests for fee waiver or reduction. 1703.109 Section 1703.109 Energy DEFENSE NUCLEAR FACILITIES SAFETY BOARD PUBLIC INFORMATION AND REQUESTS § 1703.109 Procedure for appeal of denial...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 4 2013-01-01 2013-01-01 false Procedure for appeal of denial of requests for board records and denial of requests for fee waiver or reduction. 1703.109 Section 1703.109 Energy DEFENSE NUCLEAR FACILITIES SAFETY BOARD PUBLIC INFORMATION AND REQUESTS § 1703.109 Procedure for appeal of denial...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 4 2010-01-01 2010-01-01 false Procedure for appeal of denial of requests for board records and denial of requests for fee waiver or reduction. 1703.109 Section 1703.109 Energy DEFENSE NUCLEAR FACILITIES SAFETY BOARD PUBLIC INFORMATION AND REQUESTS § 1703.109 Procedure for appeal of denial...
Asher, Elad; Mansour, John; Wheeler, Adam; Kendrick, Daniel; Cunningham, Michael; Parikh, Sahil; Zidar, David; Harford, Todd; Simon, Daniel I; Kashyap, Vikram S
2017-06-01
We initiated the SHOPPING Trial (Show How Options in Price for Procedures can be InflueNced Greatly) to see if percutaneous coronary intervention (PCI) procedures can be performed at a lower cost in a single institution. Procedural practice variability is associated with inefficiency and increased cost. We hypothesized that announcing costs for all supplies during a catheterization procedure and reporting individual operator cost relative to peers would spur cost reduction without affecting clinical outcomes. Baseline costs of 10 consecutive PCI procedures performed by 9 interventional cardiologists were documented during a 90-day interval. Costs were reassessed after instituting cost announcing and peer reporting the next quarter. The intervention involved labeling of all endovascular supplies, equipment, devices, and disposables in the catheterization laboratory and announcement of the unit price for each piece when requested. For each interventionalist, procedure time and costs were measured and analyzed prior to and after the intervention. We found that total PCI procedural cost was significantly reduced by an average of $234.77 (P = 0.01), equating to a total savings of $21,129.30 over the course of 90 PCI procedures. Major Adverse Cardiac and Cerebrovascular Event (MACCE) rates were similar during both periods (2.3% vs. 3.5%, P = NS). Announcing costs in the catheterization laboratory during single vessel PCI and peer reporting leads to cost reduction without affecting clinical outcomes. This intervention may have a role in more complex coronary and peripheral interventional procedures, and in other procedural areas where multiple equipment and device alternatives with variable costs are available. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Efficient model reduction of parametrized systems by matrix discrete empirical interpolation
NASA Astrophysics Data System (ADS)
Negri, Federico; Manzoni, Andrea; Amsallem, David
2015-12-01
In this work, we apply a Matrix version of the so-called Discrete Empirical Interpolation (MDEIM) for the efficient reduction of nonaffine parametrized systems arising from the discretization of linear partial differential equations. Dealing with affinely parametrized operators is crucial in order to enhance the online solution of reduced-order models (ROMs). However, in many cases such an affine decomposition is not readily available, and must be recovered through (often) intrusive procedures, such as the empirical interpolation method (EIM) and its discrete variant DEIM. In this paper we show that MDEIM represents a very efficient approach to deal with complex physical and geometrical parametrizations in a non-intrusive, efficient and purely algebraic way. We propose different strategies to combine MDEIM with a state approximation resulting either from a reduced basis greedy approach or Proper Orthogonal Decomposition. A posteriori error estimates accounting for the MDEIM error are also developed in the case of parametrized elliptic and parabolic equations. Finally, the capability of MDEIM to generate accurate and efficient ROMs is demonstrated on the solution of two computationally-intensive classes of problems occurring in engineering contexts, namely PDE-constrained shape optimization and parametrized coupled problems.
High-speed three-dimensional measurements with a fringe projection-based optical sensor
NASA Astrophysics Data System (ADS)
Bräuer-Burchardt, Christian; Breitbarth, Andreas; Kühmstedt, Peter; Notni, Gunther
2014-11-01
An optical three-dimensional (3-D) sensor based on a fringe projection technique that realizes the acquisition of the surface geometry of small objects was developed for highly resolved and ultrafast measurements. It realizes a data acquisition rate up to 60 high-resolution 3-D datasets per second. The high measurement velocity was achieved by consequent fringe code reduction and parallel data processing. The reduction of the length of the fringe image sequence was obtained by omission of the Gray code sequence using the geometric restrictions of the measurement objects and the geometric constraints of the sensor arrangement. The sensor covers three different measurement fields between 20 mm×20 mm and 40 mm×40 mm with a spatial resolution between 10 and 20 μm, respectively. In order to obtain a robust and fast recalibration of the sensor after change of the measurement field, a calibration procedure based on single shot analysis of a special test object was applied which works with low effort and time. The sensor may be used, e.g., for quality inspection of conductor boards or plugs in real-time industrial applications.
Outlet obstruction constipation (anismus) managed by biofeedback.
Kawimbe, B M; Papachrysostomou, M; Binnie, N R; Clare, N; Smith, A N
1991-01-01
Fifteen subjects presenting with intractable constipation due to obstructive defecation, mean (SEM) duration 8.8 (1.8) years, had the inappropriate contraction and electromyographic changes in the pelvic floor muscles and external and sphincter typical of this condition. An electromyographically derived index was used to grade its severity. A self applied biofeedback device was used to allow electromyographic recording of the abnormal external anal sphincter. The subjects were encouraged to reduce the abnormal electromyographic activity on straining after instruction and training. The procedure was intended as a relearning process in which the non-relaxing activity of the pelvic floor was gradually suppressed. Biofeedback training was maintained on a domiciliary basis for a mean time of 3.1 weeks and resulted in a significant reduction in the anismus index (mean (SEM) 69.9 (7.8)% before biofeedback, mean 14 (3.9)% after biofeedback, p less than 0.01). There was an associated reduction in the time spent straining at stool and in the difficulty of defecation and an increased frequency of defecation. Defecatory video proctograms in six subjects showed improvements in the anorectal angle during straining and evacuation. The clinical benefit to the patients persisted after a mean follow up of 6.2 months. PMID:1955173
Outlet obstruction constipation (anismus) managed by biofeedback.
Kawimbe, B M; Papachrysostomou, M; Binnie, N R; Clare, N; Smith, A N
1991-10-01
Fifteen subjects presenting with intractable constipation due to obstructive defecation, mean (SEM) duration 8.8 (1.8) years, had the inappropriate contraction and electromyographic changes in the pelvic floor muscles and external and sphincter typical of this condition. An electromyographically derived index was used to grade its severity. A self applied biofeedback device was used to allow electromyographic recording of the abnormal external anal sphincter. The subjects were encouraged to reduce the abnormal electromyographic activity on straining after instruction and training. The procedure was intended as a relearning process in which the non-relaxing activity of the pelvic floor was gradually suppressed. Biofeedback training was maintained on a domiciliary basis for a mean time of 3.1 weeks and resulted in a significant reduction in the anismus index (mean (SEM) 69.9 (7.8)% before biofeedback, mean 14 (3.9)% after biofeedback, p less than 0.01). There was an associated reduction in the time spent straining at stool and in the difficulty of defecation and an increased frequency of defecation. Defecatory video proctograms in six subjects showed improvements in the anorectal angle during straining and evacuation. The clinical benefit to the patients persisted after a mean follow up of 6.2 months.
Hybrid CMS methods with model reduction for assembly of structures
NASA Technical Reports Server (NTRS)
Farhat, Charbel
1991-01-01
Future on-orbit structures will be designed and built in several stages, each with specific control requirements. Therefore there must be a methodology which can predict the dynamic characteristics of the assembled structure, based on the dynamic characteristics of the subassemblies and their interfaces. The methodology developed by CSC to address this issue is Hybrid Component Mode Synthesis (HCMS). HCMS distinguishes itself from standard component mode synthesis algorithms in the following features: (1) it does not require the subcomponents to have displacement compatible models, which makes it ideal for analyzing the deployment of heterogeneous flexible multibody systems, (2) it incorporates a second-level model reduction scheme at the interface, which makes it much faster than other algorithms and therefore suitable for control purposes, and (3) it does answer specific questions such as 'how does the global fundamental frequency vary if I change the physical parameters of substructure k by a specified amount?'. Because it is based on an energy principle rather than displacement compatibility, this methodology can also help the designer to define an assembly process. Current and future efforts are devoted to applying the HCMS method to design and analyze docking and berthing procedures in orbital construction.
Computer-oriented emissions inventory procedure for urban and industrial sources
DOE Office of Scientific and Technical Information (OSTI.GOV)
Runca, E.; Zannetti, P.; Melli, P.
1978-06-01
A knowledge of the rate of emission of atmospheric pollutants is essential for the enforcement of air quality control policies. A computer-oriented emission inventory procedure has been developed and applied to Venice, Italy. By using optically readable forms this procedure avoids many of the errors inherent in the transcription and punching steps typical of approaches applied so far. Moreover, this procedure allows an easy updating of the inventory. Emission patterns of SO/sub 2/ in the area of Venice showed that the total urban emissions were about 6% of those emitted by industrial sources.
ERIC Educational Resources Information Center
Ravia, Silvana; Gamenara, Daniela; Schapiro, Valeria; Bellomo, Ana; Adum, Jorge; Seoane, Gustavo; Gonzalez, David
2006-01-01
The use of biocatalysis and biotransformations are important tools in green chemistry. The enantioselective reduction of a ketone by crude plant parts, using carrot ("Daucus carota") as the reducing agent is presented. The experiment introduces an example of a green chemistry procedure that can be tailored to fit in a regular laboratory session.…
NASA Technical Reports Server (NTRS)
Cassell, Rick; Smith, Alex; Connors, Mary; Wojciech, Jack; Rosekind, Mark R. (Technical Monitor)
1996-01-01
As new technologies and procedures are introduced into the National Airspace System, whether they are intended to improve efficiency, capacity, or safety level, the quantification of potential changes in safety levels is of vital concern. Applications of technology can improve safety levels and allow the reduction of separation standards. An excellent example is the Precision Runway Monitor (PRM). By taking advantage of the surveillance and display advances of PRM, airports can run instrument parallel approaches to runways separated by 3400 feet with the same level of safety as parallel approaches to runways separated by 4300 feet using the standard technology. Despite a wealth of information from flight operations and testing programs, there is no readily quantifiable relationship between numerical safety levels and the separation standards that apply to aircraft on final approach. This paper presents a modeling approach to quantify the risk associated with reducing separation on final approach. Reducing aircraft separation, both laterally and longitudinally, has been the goal of several aviation R&D programs over the past several years. Many of these programs have focused on technological solutions to improve navigation accuracy, surveillance accuracy, aircraft situational awareness, controller situational awareness, and other technical and operational factors that are vital to maintaining flight safety. The risk assessment model relates different types of potential aircraft accidents and incidents and their contribution to overall accident risk. The framework links accident risks to a hierarchy of failsafe mechanisms characterized by procedures and interventions. The model will be used to assess the overall level of safety associated with reducing separation standards and the introduction of new technology and procedures, as envisaged under the Free Flight concept. The model framework can be applied to various aircraft scenarios, including parallel and in-trail approaches. This research was performed under contract to NASA and in cooperation with the FAA's Safety Division (ASY).
An Overhead Demonstration of Some Descriptive Chemistry of the Halogens and LeChatelier's Principle.
ERIC Educational Resources Information Center
Hansen, Robert C.
1988-01-01
Describes a demonstration procedure using controlled reduction potentials to predict observed color changes which are then experimentally verified. Demonstrates the usefulness of this procedure in helping students understand LeChatelier's principle and the solubilit rule "like dissolves like." (CW)
Which causes more ergonomic stress: Laparoscopic or open surgery?
Wang, Robert; Liang, Zhe; Zihni, Ahmed M; Ray, Shuddhadeb; Awad, Michael M
2017-08-01
There is increasing awareness of potential ergonomic challenges experienced by the laparoscopic surgeon. The purpose of this study is to quantify and compare the ergonomic stress experienced by a surgeon while performing open versus laparoscopic portions of a procedure. We hypothesize that a surgeon will experience greater ergonomic stress when performing laparoscopic surgery. We designed a study to measure upper-body muscle activation during the laparoscopic and open portions of sigmoid colectomies in a single surgeon. A sample of five cases was recorded over a two-month time span. Each case contained significant portions of laparoscopic and open surgery. We obtained whole-case electromyography (EMG) tracings from bilateral biceps, triceps, deltoid, and trapezius muscles. After normalization to a maximum voltage of contraction (%MVC), these EMG tracings were used to calculate average muscle activation during the open and laparoscopic segments of each procedure. Paired Student's t test was used to compare the average muscle activation between the two groups (*p < 0.05 considered statistically significant). Significant reductions in mean muscle activation in laparoscopic compared to open procedures were noted for the left triceps (4.07 ± 0.44% open vs. 2.65 ± 0.54% lap, 35% reduction), left deltoid (2.43 ± 0.45% open vs. 1.32 ± 0.16% lap, 46% reduction), left trapezius (9.93 ± 0.1.95% open vs. 4.61 ± 0.67% lap, 54% reduction), right triceps (2.94 ± 0.62% open vs. 1.85 ± 0.28% lap, 37% reduction), and right trapezius (10.20 ± 2.12% open vs. 4.69 ± 1.18% lap, 54% reduction). Contrary to our hypothesis, the laparoscopic approach provided ergonomic benefit in several upper-body muscle groups compared to the open approach. This may be due to the greater reach of laparoscopic instruments and camera in the lower abdomen/pelvis. Patient body habitus may also have less of an effect in the laparoscopic compared to open approach. Future studies with multiple subjects and different types of procedures are planned to further investigate these findings.
Is it safe to use local anesthesia with adrenaline in hand surgery? WALANT technique.
Pires Neto, Pedro José; Moreira, Leonardo de Andrade; Las Casas, Priscilla Pires de
2017-01-01
In the past it was taught that local anesthetic should not be used with adrenaline for procedures in the extremities. This dogma is transmitted from generation to generation. Its truth has not been questioned, nor the source of the doubt. In many situations the benefit of use was not understood, because it was often thought that it was not necessary to prolong the anesthetic effect, since the procedures were mostly of short duration. After the disclosure of studies of Canadian surgeons, came to understand that the benefits went beyond the time of anesthesia. The WALANT technique allows a surgical field without bleeding, possibility of information exchange with the patient during the procedure, reduction of waste material, reduction of costs, and improvement of safety. Thus, after passing through the initial phase of the doubts in the use of this technique, the authors verified its benefits and the patients' satisfaction in being able to immediately return home after the procedures.