  1. The CERN-EU high-energy Reference Field (CERF) facility: applications and latest developments

    NASA Astrophysics Data System (ADS)

    Silari, Marco; Pozzi, Fabio

    2017-09-01

    The CERF facility at CERN provides an almost unique high-energy workplace reference radiation field for the calibration and test of radiation protection instrumentation employed at high-energy accelerator facilities and for aircraft and space dosimetry. This paper describes the main features of the facility and supplies a non-exhaustive list of recent (as of 2005) applications for which CERF is used. Upgrade work started in 2015 to provide the scientific and industrial communities with a state-of-the-art reference facility is also discussed.

  2. Geant4 simulation of the CERN-EU high-energy reference field (CERF) facility.

    PubMed

    Prokopovich, D A; Reinhard, M I; Cornelius, I M; Rosenfeld, A B

    2010-09-01

    The CERN-EU high-energy reference field facility is used for testing and calibrating both active and passive radiation dosemeters for radiation protection applications in space and aviation. Through a combination of a primary particle beam, target and a suitable designed shielding configuration, the facility is able to reproduce the neutron component of the high altitude radiation field relevant to the jet aviation industry. Simulations of the facility using the GEANT4 (GEometry ANd Tracking) toolkit provide an improved understanding of the neutron particle fluence as well as the particle fluence of other radiation components present. The secondary particle fluence as a function of the primary particle fluence incident on the target and the associated dose equivalent rates were determined at the 20 designated irradiation positions available at the facility. Comparisons of the simulated results with previously published simulations obtained using the FLUKA Monte Carlo code, as well as with experimental results of the neutron fluence obtained with a Bonner sphere spectrometer, are made.

  3. Reference field specification and preliminary beam selection strategy for accelerator-based GCR simulation

    NASA Astrophysics Data System (ADS)

    Slaba, Tony C.; Blattnig, Steve R.; Norbury, John W.; Rusek, Adam; La Tessa, Chiara

    2016-02-01

    The galactic cosmic ray (GCR) simulator at the NASA Space Radiation Laboratory (NSRL) is intended to deliver the broad spectrum of particles and energies encountered in deep space to biological targets in a controlled laboratory setting. In this work, certain aspects of simulating the GCR environment in the laboratory are discussed. Reference field specification and beam selection strategies at NSRL are the main focus, but the analysis presented herein may be modified for other facilities and possible biological considerations. First, comparisons are made between direct simulation of the external, free space GCR field and simulation of the induced tissue field behind shielding. It is found that upper energy constraints at NSRL limit the ability to simulate the external, free space field directly (i.e. shielding placed in the beam line in front of a biological target and exposed to a free space spectrum). Second, variation in the induced tissue field associated with shielding configuration and solar activity is addressed. It is found that the observed variation is likely within the uncertainty associated with representing any GCR reference field with discrete ion beams in the laboratory, given current facility constraints. A single reference field for deep space missions is subsequently identified. Third, a preliminary approach for selecting beams at NSRL to simulate the designated reference field is presented. This approach is not a final design for the GCR simulator, but rather a single step within a broader design strategy. It is shown that the beam selection methodology is tied directly to the reference environment, allows facility constraints to be incorporated, and may be adjusted to account for additional constraints imposed by biological or animal care considerations. The major biology questions are not addressed herein but are discussed in a companion paper published in the present issue of this journal. Drawbacks of the proposed methodology are discussed and weighed against alternative simulation strategies.

  4. GCR Simulator Reference Field and a Spectral Approach for Laboratory Simulation

    NASA Technical Reports Server (NTRS)

    Slaba, Tony C.; Blattnig, Steve R.; Norbury, John W.; Rusek, Adam; La Tessa, Chiara; Walker, Steven A.

    2015-01-01

    The galactic cosmic ray (GCR) simulator at the NASA Space Radiation Laboratory (NSRL) is intended to deliver the broad spectrum of particles and energies encountered in deep space to biological targets in a controlled laboratory setting. In this work, certain aspects of simulating the GCR environment in the laboratory are discussed. Reference field specification and beam selection strategies at NSRL are the main focus, but the analysis presented herein may be modified for other facilities. First, comparisons are made between direct simulation of the external, free space GCR field and simulation of the induced tissue field behind shielding. It is found that upper energy constraints at NSRL limit the ability to simulate the external, free space field directly (i.e. shielding placed in the beam line in front of a biological target and exposed to a free space spectrum). Second, variation in the induced tissue field associated with shielding configuration and solar activity is addressed. It is found that the observed variation is likely within the uncertainty associated with representing any GCR reference field with discrete ion beams in the laboratory, given current facility constraints. A single reference field for deep space missions is subsequently identified. Third, an approach for selecting beams at NSRL to simulate the designated reference field is presented. Drawbacks of the proposed methodology are discussed and weighed against alternative simulation strategies. The neutron component and track structure characteristics of the simulated field are discussed in this context.

  5. Development of an Implantable Fish Spawning Sensor Tag

    DTIC Science & Technology

    2013-09-24

    Manatee Hatchery Facility, Port Manatee , Florida) using a Millar Instruments pressure catheter inserted a fixed distance (15cm) into the ovary before and...red drum aquaculture facility in Port Manatee , Florida (or similar aquaculture facility where spawning fishes are kept). This facility maintains a...at the Port Manatee hatchery and phase three tests on goliath grouper in the field. RESULTS *Please refer to other sections for more details and

  6. Field assessment of dried Plasmodium falciparum samples for malaria rapid diagnostic test quality control and proficiency testing in Ethiopia.

    PubMed

    Tamiru, Afework; Boulanger, Lucy; Chang, Michelle A; Malone, Joseph L; Aidoo, Michael

    2015-01-21

    Rapid diagnostic tests (RDTs) are now widely used for laboratory confirmation of suspected malaria cases to comply with the World Health Organization recommendation for universal testing before treatment. However, many malaria programmes lack quality control (QC) processes to assess RDT use under field conditions. Prior research showed the feasibility of using the dried tube specimen (DTS) method for preserving Plasmodium falciparum parasites for use as QC samples for RDTs. This study focused on the use of DTS for RDT QC and proficiency testing under field conditions. DTS were prepared using cultured P. falciparum at densities of 500 and 1,000 parasites/μL; 50 μL aliquots of these along with parasite negative human blood controls (0 parasites/μL) were air-dried in specimen tubes and reactivity verified after rehydration. The DTS were used in a field study in the Oromia Region of Ethiopia. Replicate DTS samples containing 0, 500 and 1,000 parasites/μL were stored at 4°C at a reference laboratory and at ambient temperatures at two nearby health facilities. At weeks 0, 4, 8, 12, 16, 20, and 24, the DTS were rehydrated and tested on RDTs stored under manufacturer-recommended temperatures at the RL and on RDTs stored under site-specific conditions at the two health facilities. Reactivity of DTS stored at 4°C at the reference laboratory on RDTs stored at the reference laboratory was considered the gold standard for assessing DTS stability. A proficiency-testing panel consisting of one negative and three positive samples, monitored with a checklist was administered at weeks 12 and 24. At all the seven time points, DTS stored at both the reference laboratory and health facility were reactive on RDTs stored under the recommended temperature and under field conditions, and the DTS without malaria parasites were negative. At the reference laboratory and one health facility, a 500 parasites/μL DTS from the proficiency panel was falsely reported as negative at week 24 due to errors in interpreting faint test lines. The DTS method can be used under field conditions to supplement other RDT QC methods and health worker proficiency in Ethiopia and possibly other malaria-endemic countries.

  7. The CERN-EU high-energy reference field (CERF) facility for dosimetry at commercial flight altitudes and in space.

    PubMed

    Mitaroff, A; Cern, M Silari

    2002-01-01

    A reference facility for the calibration and intercomparison of active and passive detectors in broad neutron fields has been available at CERN since 1992. A positively charged hadron beam (a mixture of protons and pions) with momentum of 120 GeV/c hits a copper target, 50 cm thick and 7 cm in diameter. The secondary particles produced in the interaction traverse a shield, at 90 degrees with respect to the direction of the incoming beam. made of either 80 to 160 cm of concrete or 40 cm of iron. Behind the iron shield, the resulting neutron spectrum has a maximum at about 1 MeV, with an additional high-energy component. Behind the 80 cm concrete shield, the neutron spectrum has a second pronounced maximum at about 70 MeV and resembles the high-energy component of the radiation field created by cosmic rays at commercial flight altitudes. This paper describes the facility, reports on the latest neutron spectral measurements, gives an overview of the most important experiments performed by the various collaborating institutions over recent years and briefly addresses the possible application of the facility to measurements related to the space programme.

  8. Instrument intercomparison in the high-energy mixed field at the CERN-EU reference field (CERF) facility.

    PubMed

    Caresana, Marco; Helmecke, Manuela; Kubancak, Jan; Manessi, Giacomo Paolo; Ott, Klaus; Scherpelz, Robert; Silari, Marco

    2014-10-01

    This paper discusses an intercomparison campaign performed in the mixed radiation field at the CERN-EU (CERF) reference field facility. Various instruments were employed: conventional and extended-range rem counters including a novel instrument called LUPIN, a bubble detector using an active counting system (ABC 1260) and two tissue-equivalent proportional counters (TEPCs). The results show that the extended range instruments agree well within their uncertainties and within 1σ with the H*(10) FLUKA value. The conventional rem counters are in good agreement within their uncertainties and underestimate H*(10) as measured by the extended range instruments and as predicted by FLUKA. The TEPCs slightly overestimate the FLUKA value but they are anyhow consistent with it when taking the comparatively large total uncertainties into account, and indicate that the non-neutron part of the stray field accounts for ∼30 % of the total H*(10). © The Author 2013. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  9. Survey of referring veterinarians' perceptions of and reasons for referring patients to rehabilitation facilities.

    PubMed

    Alvarez, Leilani X; Fox, Philip R; Van Dyke, Janet B; Grigsby, Patrick

    2016-10-01

    OBJECTIVE To identify patterns of referral to US small animal rehabilitation facilities, document referring veterinarians' perceptions of rehabilitation services, and examine factors that encouraged and impeded referral of veterinary patients to rehabilitation facilities. DESIGN Cross-sectional survey. SAMPLE 461 completed surveys. PROCEDURES Referral lists were obtained from 9 US rehabilitation facilities, and surveys were emailed or mailed to 2, 738 veterinarians whose names appeared on those lists. Data obtained from respondents were used to generate descriptive statistics and perform χ(2) tests to determine patterns for referral of patients to rehabilitation facilities. RESULTS 461 surveys were completed and returned, resulting in a response rate of 16.8%. The margin of error was < 5% for all responses. Most respondents (324/461 [70.3%]) had referred patients for postoperative rehabilitation therapy. Respondents ranked neurologic disorder as the condition they would most likely consider for referral for future rehabilitation therapy. The most frequently cited reason for not referring a patient for rehabilitation therapy was perceived cost (251/461 [54.4%]) followed by distance to a rehabilitation facility (135/461 [29.3%]). Specialists were more likely than general practitioners to refer patients for rehabilitation therapy. The majority (403/461 [87.4%]) of respondents felt that continuing education in the field of veterinary rehabilitation was lacking. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated a need for continuing education in small animal rehabilitation for veterinarians. Improved knowledge of rehabilitation therapy will enable veterinarians to better understand and more specifically communicate indications and benefits for pets receiving this treatment modality.

  10. An Annotated List of Marine Stations Suitable for Field Courses in Carbonate Geology and Tropical Marine Sciences.

    ERIC Educational Resources Information Center

    Kaplan, Eugene H.

    1980-01-01

    This is an annotated list of marine field stations suitable for summer study or research in carbonate geology and tropical marine sciences. Thirteen are listed and described in detail. Equipment is discussed and reference is made to research-oriented Caribbean facilities for graduate study or field courses. (Author/SA)

  11. 29 CFR 1610.4 - Public reference facilities and current index.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    .... Cleveland Field Office (Philadelphia District), 1240 E. 9th Street, Suite 3001, Cleveland, OH 44199. Dallas District Office, 207 S. Houston Street, 3rd Floor, Dallas, TX 75202-4726. Denver Field Office (Phoenix...), 477 Michigan Avenue, Room 865, Detroit, MI 48226-2523. El Paso Area Office (Dallas District), 300 East...

  12. Technical Basis Document for Internal Dosimetry at Sandia National Laboratories Revision 2.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Potter, Charles A.

    2014-09-01

    The RPID Project will be implemented at all SNL facilities for activities involving the processing and/or storing of radioactive materials. This project includes activities at the Tech Area (TA) I, TA II, TA III, TA IV, TA V, Coyote Test Field, and environmental restoration sites at SNL, located in Albuquerque, New Mexico, and the Kauai Test Facility(SNL/KTF). Reference to SNL throughout this document includes facilities and activities at the Albuquerque location and at SNL/KTF.

  13. Expanding Your Laboratory by Accessing Collaboratory Resources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoyt, David W.; Burton, Sarah D.; Peterson, Michael R.

    2004-03-01

    The Environmental Molecular Sciences Laboratory (EMSL) in Richland, Washington, is the home of a research facility setup by the United States Department of Energy (DOE). The facility is atypical because it houses over 100 cutting-edge research systems for the use of researchers all over the United States and the world. Access to the lab is requested through a peer-review proposal process and the scientists who use the facility are generally referred to as ‘users’. There are six main research facilities housed in EMSL, all of which host visiting researchers. Several of these facilities also participate in the EMSL Collaboratory, amore » remote access capability supported by EMSL operations funds. Of these, the High-Field Magnetic Resonance Facility (HFMRF) and Molecular Science Computing Facility (MSCF) have a significant number of their users performing remote work. The HFMRF in EMSL currently houses 12 NMR spectrometers that range in magnet field strength from 7.05T to 21.1T. Staff associated with the NMR facility offers scientific expertise in the areas of structural biology, solid-state materials/catalyst characterization, and magnetic resonance imaging (MRI) techniques. The way in which the HFMRF operates, with a high level of dedication to remote operation across the full suite of High-Field NMR spectrometers, has earned it the name “Virtual NMR Facility”. This review will focus on the operational aspects of remote research done in the High-Field Magnetic Resonance Facility and the computer tools that make remote experiments possible.« less

  14. Monte Carlo simulation of the operational quantities at the realistic mixed neutron-photon radiation fields CANEL and SIGMA.

    PubMed

    Lacoste, V; Gressier, V

    2007-01-01

    The Institute for Radiological Protection and Nuclear Safety owns two facilities producing realistic mixed neutron-photon radiation fields, CANEL, an accelerator driven moderator modular device, and SIGMA, a graphite moderated americium-beryllium assembly. These fields are representative of some of those encountered at nuclear workplaces, and the corresponding facilities are designed and used for calibration of various instruments, such as survey meters, personal dosimeters or spectrometric devices. In the framework of the European project EVIDOS, irradiations of personal dosimeters were performed at CANEL and SIGMA. Monte Carlo calculations were performed to estimate the reference values of the personal dose equivalent at both facilities. The Hp(10) values were calculated for three different angular positions, 0 degrees, 45 degrees and 75 degrees, of an ICRU phantom located at the position of irradiation.

  15. Referenced-site environmental document for a Monitored Retrievable Storage facility: backup waste management option for handling 1800 MTU per year

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Silviera, D.J.; Aaberg, R.L.; Cushing, C.E.

    This environmental document includes a discussion of the purpose of a monitored retrievable storage facility, a description of two facility design concepts (sealed storage cask and field drywell), a description of three reference sites (arid, warm-wet, and cold-wet), and a discussion and comparison of the impacts associated with each of the six site/concept combinations. This analysis is based on a 15,000-MTU storage capacity and a throughput rate of up to 1800 MTU per year.

  16. Facilities Utilization Program Implementation Handbook

    NASA Technical Reports Server (NTRS)

    1987-01-01

    This Facilities Utilization Program Implementation Handbook (FUPIH) prescribes procedures for the review and the reporting on the utilization of NASA facilities. The Directors of NASA Field Installations should designate an Installation Official responsible for coordinating the assignment of buildings space and implementing the facilities utilization reviews and annual report preparation. The individual designated shall be known as the 'Facilities Utilization Officer (FUO).' Functional responsibilities of the FUO are detailed in NASA Management Instruction (NMI) 7234.1. It is recognized that titles used in the implementation of the Facilities Utilization Program may vary between field installations. The Facilities Utilization Program (FUP) is designed to provide a uniform and orderly process for meeting or addressing the following objectives: the establishment of sound facilities requirements to meet NASA's programmatic and institutional needs; the optimum allocation of available facilities and related resources to meet these requirements; and the early identification and request for required additional facilities resources. The detailed review and reporting system enacted by NMI 7234.1 should encourage more comprehensive utilization planning for all NASA facilities and ensure, to the maximum extent practicable, that all such facilities are put to their highest and best use consistent with NASA programmatic and institutional priorities. A principal purpose of the FUP is the early identification of NASA facilities which may be or may become underutilized or excess to NASA needs and to provide a timely reference point from which corrective actions (i.e., consolidation, elimination of duplication, improved utilization of disposal) may be taken. Because the supply of this handbook is limited, distribution should be controlled at the field installation level.

  17. Sports Fields: A Manual for Design Construction and Maintenance.

    ERIC Educational Resources Information Center

    Puhalla, Jim; Krans, Jeff; Goatley, Mike

    Comprehensive technical reference information is provided for those responsible for the design, construction, renovation, or maintenance of sports grounds. Chapters illustrate specific design elements of all popular sports facilities, and explain how those elements are integrated in a successful project; explore commonly encountered sports field…

  18. Shooting and Hunting: Instructor's Guide.

    ERIC Educational Resources Information Center

    Smith, Julian W., Comp.

    The shooting and hunting manual, part of a series of books and pamphlets on outdoor education, explains shooting skills, hunting, and proper gun handling on the range and in the field. This manual should be supplemented and enriched by available references, facilities, and resources. It may be included in the community's educational and…

  19. Planning School Grounds for Outdoor Learning

    ERIC Educational Resources Information Center

    Wagner, Cheryl; Gordon, Douglas

    2010-01-01

    This publication covers the planning and design of school grounds for outdoor learning in new and existing K-12 facilities. Curriculum development as well as athletic field planning and maintenance are not covered although some references on these topics are provided. It discusses the different types of outdoor learning environments that can be…

  20. 29 CFR 1610.4 - Public reference facilities and current index.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (New York District), 1 Newark Center, 21st Floor, Newark, NJ 07102-5233. New Orleans Field Office (Houston District), 1555 Poydras, Suite 1900, New Orleans, LA 70112. New York District Office, 33 Whitehall..., Birmingham, AL 35205-2397. Boston Area Office (New York District), John F. Kennedy Federal Building...

  1. Performance of the electronic personal dosemeter for neutron 'Saphydose-N' at different workplaces of nuclear facilities.

    PubMed

    Lahaye, T; Chau, Q; Ménard, S; Lacoste, V; Muller, H; Luszik-Bhadra, M; Reginatto, M; Bruguier, P

    2006-01-01

    This paper mainly aims at presenting the measurements and the results obtained with the electronic personal neutron dosemeter Saphydose-N at different facilities. Three campaigns were led in the frame of the European contract EVIDOS ('Evaluation of Individual Dosimetry in Mixed Neutron and Photon Radiation Fields'). The first one consisted in the measurements at the IRSN French research laboratory in reference neutron fields generated by a thermal facility (SIGMA), radionuclide ISO sources ((241)AmBe; (252)Cf; (252)Cf(D(2)O)\\Cd) and a realistic spectrum (CANEL/T400). The second one was performed at the Krümmel Nuclear Power Plant (Germany) close to the boiling water reactor and to a spent fuel transport cask. The third one was realised at Mol (Belgium), at the VENUS Research Reactor and at Belgonucléaire, a fuel processing factory.

  2. Field Test of the Methodology for Succession Planning for Technical Experts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cain, Ronald A.; Kirk, Bernadette Lugue; Agreda, Carla L.

    This report complements A Methodology for Succession Planning for Technical Experts (Ron Cain, Shaheen Dewji, Carla Agreda, Bernadette Kirk, July 2017), which describes a methodology for identifying and evaluating the loss of key technical skills at nuclear operations facilities. This report targets the methodology for identifying critical skills, hereafter referred to as “core competencies”. The methodology has been field tested by interviewing selected retiring subject matter experts (SMEs).

  3. Satellite services system analysis study. Volume 3A: Service equipment requirements, appendix

    NASA Technical Reports Server (NTRS)

    1981-01-01

    Spacecraft descriptions and mission sequences, mission and servicing operations functional analyses, servicing requirements, and servicing equipment are discussed for five reference satellites: the X-ray Timing Explorer, the Upper Atmospheric Research Satellite, the Advanced X-ray Astrophysics Facility, the Earth Gravity Field Survey Mission, and the Orbiting Astronomical Observatory.

  4. VHF Omnidirectional Radio Range (VOR) Electromagnetic Spectrum Measurements.

    DTIC Science & Technology

    1978-10-18

    MAINTENANCE AND INSPECTION OF VOR, DVOR FACILITIES. 9-42 mouce & Io 10/18/78 Page 9-1 VHF OMNI-DIRECTIONAL RADIO RANGE (VOR) ELECTROMAGNETIC SPECTRUM...developed by the rotating sideband pattern 0r Pattern shown at North 00 North position Reference30 R--Variable ....uRlerent Cardioid-shaped Field Pattern...to their respective antenna pairs (which are 1800 out of phase with each other). This combination creates a two lobe field pattern rotating at 30 rps

  5. The insertion device magnetic measurement facility: Prototype and operational procedures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burkel, L.; Dejus, R.; Maines, J.

    1993-03-01

    This report is a description of the current status of the magnetic measurement facility and is a basic instructional manual for the operation of the facility and its components. Please refer to the appendices for more detailed information about specific components and procedures. The purpose of the magnetic measurement facility is to take accurate measurements of the magnetic field in the gay of the IDs in order to determine the effect of the ID on the stored particle beam and the emitted radiation. The facility will also play an important role when evaluating new ideas, novel devices, and inhouse prototypesmore » as part of the ongoing research and development program at the APS. The measurements will be performed with both moving search coils and moving Hall probes. The IDs will be evaluated by computer modeling of the emitted radiation for any given (measured) magnetic field map. The quality of the magnetic field will be described in terms of integrated multipoles for the effect on Storage Ring performance and in terms of the derived trajectories for the emitted radiation. Before being installed on the Storage Ring, every device will be measured and characterized to assure that it is compatible with Storage Ring requirements and radiation specifications. The accuracy that the APS needs to achieve for magnetic measurements will be based on these specifications.« less

  6. Validation of IRDFF in 252Cf standard and IRDF-2002 reference neutron fields

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Simakov, Stanislav; Capote Noy, Roberto; Greenwood, Lawrence R.

    The results of validation of the latest release of International Reactor Dosimetry and Fusion File, IRDFF-1.03, in the standard 252Cf(s.f.) and reference 235U(nth,f) neutron benchmark fields are presented. The spectrum-averaged cross sections were shown to confirm the recommended spectrum for 252Cf spontaneous fission source; that was not the case for the current recommended spectra for 235U(nth,f). IRDFF was also validated in the spectra of the research reactor facilities ISNF, Sigma-Sigma and YAYOI, which are available in the IRDF- 2002 collection. Before this analysis, the ISFN spectrum was resimulated to remove unphysical oscillations in spectrum. IRDFF-1.03 was shown to reasonably reproducemore » the spectrum-averaged data measured in these fields except for the case of YAYOI.« less

  7. Groundwater flow simulation of the Savannah River Site general separations area

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Flach, G.; Bagwell, L.; Bennett, P.

    The most recent groundwater flow model of the General Separations Area, Savannah River Site, is referred to as the “GSA/PORFLOW” model. GSA/PORFLOW was developed in 2004 by porting an existing General Separations Area groundwater flow model from the FACT code to the PORFLOW code. The preceding “GSA/FACT” model was developed in 1997 using characterization and monitoring data through the mid-1990’s. Both models were manually calibrated to field data. Significantly more field data have been acquired since the 1990’s and model calibration using mathematical optimization software has become routine and recommended practice. The current task involved updating the GSA/PORFLOW model usingmore » selected field data current through at least 2015, and use of the PEST code to calibrate the model and quantify parameter uncertainty. This new GSA groundwater flow model is named “GSA2016” in reference to the year in which most development occurred. The GSA2016 model update is intended to address issues raised by the DOE Low-Level Waste (LLW) Disposal Facility Federal Review Group (LFRG) in a 2008 review of the E-Area Performance Assessment, and by the Nuclear Regulatory Commission in reviews of tank closure and Saltstone Disposal Facility Performance Assessments.« less

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burkel, L.; Dejus, R.; Maines, J.

    This report is a description of the current status of the magnetic measurement facility and is a basic instructional manual for the operation of the facility and its components. Please refer to the appendices for more detailed information about specific components and procedures. The purpose of the magnetic measurement facility is to take accurate measurements of the magnetic field in the gay of the IDs in order to determine the effect of the ID on the stored particle beam and the emitted radiation. The facility will also play an important role when evaluating new ideas, novel devices, and inhouse prototypesmore » as part of the ongoing research and development program at the APS. The measurements will be performed with both moving search coils and moving Hall probes. The IDs will be evaluated by computer modeling of the emitted radiation for any given (measured) magnetic field map. The quality of the magnetic field will be described in terms of integrated multipoles for the effect on Storage Ring performance and in terms of the derived trajectories for the emitted radiation. Before being installed on the Storage Ring, every device will be measured and characterized to assure that it is compatible with Storage Ring requirements and radiation specifications. The accuracy that the APS needs to achieve for magnetic measurements will be based on these specifications.« less

  9. 15 CFR 807.1 - Public Reference Facility.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ...) BUREAU OF ECONOMIC ANALYSIS, DEPARTMENT OF COMMERCE PUBLIC INFORMATION § 807.1 Public Reference Facility. The Public Reference Facility of the Bureau of Economic Analysis is located in room B7 of the Tower...

  10. 15 CFR 807.1 - Public Reference Facility.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ...) BUREAU OF ECONOMIC ANALYSIS, DEPARTMENT OF COMMERCE PUBLIC INFORMATION § 807.1 Public Reference Facility. The Public Reference Facility of the Bureau of Economic Analysis is located in room B7 of the Tower...

  11. 15 CFR 807.1 - Public Reference Facility.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ...) BUREAU OF ECONOMIC ANALYSIS, DEPARTMENT OF COMMERCE PUBLIC INFORMATION § 807.1 Public Reference Facility. The Public Reference Facility of the Bureau of Economic Analysis is located in room B7 of the Tower...

  12. Harnessing health information in the Third World.

    PubMed

    Coghlan, S E; Khan, M S

    1993-01-01

    The provision of technical information on health in developing countries is discussed, with particular reference to the Diarrhoeal Diseases Information Services Centre in Bangladesh. Progress towards meeting the pressing needs of the Third World in this field can undoubtedly be made by increasing the use of micrographic, computer and videodisc technologies and by reorganizing and promoting the facilities on offer.

  13. Legionella and risk management in hospitals-A bibliographic research methodology for people responsible for built environment and facility management.

    PubMed

    Leiblein, Thomas W; Tucker, Matthew; Ashall, Mal; Lee, Susanne B; Gollnisch, Carsten; Hofer, Susanne

    2016-11-01

    An ongoing research project investigates the roles and duties of persons responsible for the built environment with respect to risk management of water systems and Legionella prevention from a facility management's perspective. Our literature review provides an approach for selecting and analysing abstracts of initially 177 journal articles, subjected to certain topic-specific inclusion and exclusion criteria. Different decision strategies of either logic 'yes/no', Boolean operators 'OR' or 'AND' and decisions for single counts or cumulative counts of the identified three principal keywords 'Legionella', 'hospital' and 'water', were completed. A final list of ten principal reference articles from 29 journals was compiled. It suggests that the interconnected perspective of water systems, Legionella and hospitals seems to be underrepresented in the field of the built environment and facility management. The term 'stakeholder', which would refer to decision-makers, was not found more than once. Our result is a useful summary of established sources of information on environmental Legionella research. The results can be helpful for those new to the topic. Copyright © 2016 Elsevier GmbH. All rights reserved.

  14. Understanding health care provider barriers to hospital affiliated medical fitness center facility referral: a questionnaire survey and semi structured interviews.

    PubMed

    Smock, Carissa; Alemagno, Sonia

    2017-08-03

    The purpose of this study is to understand health care provider barriers to referring patients to Medical Fitness Center Facilities within an affiliated teaching hospital system using referral of diabetic services as an example. The aims of this study include: (1) to assess health care providers' awareness and use of facilities, (2) to determine barriers to referring patients to facilities, (3) identify current and needed resources and/or changes to increase referral to facilities. A 20-item electronic survey and requests for semi-structured interviews were administered to hospital system directors and managers (n = 51). Directors and managers instructed physicians and staff to complete the survey and interviews as applicable. Perceived barriers, knowledge, utilization, and referral of patients to Medical Fitness Center Facilities were collected and examined. Descriptive statistics were generated regarding practice characteristics, provider characteristics, and referral. Of the health care providers surveyed and interviewed (n = 25) 40% indicated verbally suggesting use of facilities, 24% provided a flyer about the facilities. No respondents indicated that they directly referred patients to the facilities. However, 16% referred patients to other locations for physical activity - including their own department's management and prevention services. 20% do not refer to Medical Fitness Center Facilities or any other lifestyle programs/locations. Lack of time (92%) and lack of standard guidelines and operating procedures (88%) are barriers to referral. All respondents indicated a strong ability to refer patients to Medical Fitness Center Facilities if given education about referral programs available as well as standard clinical guidelines and protocol for delivery. The results of this study indicate that, although few healthcare providers are currently referring patients to Medical Fitness Center Facilities, health care providers with an affiliated Medical Fitness Center Facility not only want clinical standard guidelines, protocol, and training to refer patients to Medical Fitness Center Facilities, but believe they have the ability to increase referral if given these tools. The Medical Fitness Association has a unique opportunity to bridge health care providers to Medical Fitness Center Facilities by developing clinical practice guidelines in cooperation with the American Diabetes Association.

  15. A Reference Field for GCR Simulation and an LET-Based Implementation at NSRL

    NASA Technical Reports Server (NTRS)

    Slaba, Tony C.; Blattnig, Steve R.; Walker, Steven A.; Norbury, John W.

    2015-01-01

    Exposure to galactic cosmic rays (GCR) on long duration deep space missions presents a serious health risk to astronauts, with large uncertainties connected to the biological response. In order to reduce the uncertainties and gain understanding about the basic mechanisms through which space radiation initiates cancer and other endpoints, radiobiology experiments are performed. Some of the accelerator facilities supporting such experiments have matured to a point where simulating the broad range of particles and energies characteristic of the GCR environment in a single experiment is feasible from a technology, usage, and cost perspective. In this work, several aspects of simulating the GCR environment in the laboratory are discussed. First, comparisons are made between direct simulation of the external, free space GCR field and simulation of the induced tissue field behind shielding. It is found that upper energy constraints at the NASA Space Radiation Laboratory (NSRL) limit the ability to simulate the external, free space field directly (i.e. shielding placed in the beam line in front of a biological target and exposed to a free space spectrum). Second, variation in the induced tissue field associated with shielding configuration and solar activity is addressed. It is found that the observed variation is within physical uncertainties, allowing a single reference field for deep space missions to be defined. Third, an approach for simulating the reference field at NSRL is presented. The approach allows for the linear energy transfer (LET) spectrum of the reference field to be approximately represented with discrete ion and energy beams and implicitly maintains a reasonably accurate charge spectrum (or, average quality factor). Drawbacks of the proposed methodology are discussed and weighed against alternative simulation strategies. The neutron component and track structure characteristics of the proposed strategy are discussed in this context.

  16. Radiation and Health Technology Laboratory Capabilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bihl, Donald E.; Lynch, Timothy P.; Murphy, Mark K.

    2005-07-09

    The Radiological Standards and Calibrations Laboratory, a part of Pacific Northwest National Laboratory (PNNL)(a) performs calibrations and upholds reference standards necessary to maintain traceability to national standards. The facility supports U.S. Department of Energy (DOE) programs at the Hanford Site, programs sponsored by DOE Headquarters and other federal agencies, radiological protection programs at other DOE and commercial nuclear sites and research and characterization programs sponsored through the commercial sector. The laboratory is located in the 318 Building of the Hanford Site's 300 Area. The facility contains five major exposure rooms and several laboratories used for exposure work preparation, low-activity instrumentmore » calibrations, instrument performance evaluations, instrument maintenance, instrument design and fabrication work, thermoluminescent and radiochromic Dosimetry, and calibration of measurement and test equipment (M&TE). The major exposure facilities are a low-scatter room used for neutron and photon exposures, a source well room used for high-volume instrument calibration work, an x-ray facility used for energy response studies, a high-exposure facility used for high-rate photon calibration work, a beta standards laboratory used for beta energy response studies and beta reference calibrations and M&TE laboratories. Calibrations are routinely performed for personnel dosimeters, health physics instrumentation, photon and neutron transfer standards alpha, beta, and gamma field sources used throughout the Hanford Site, and a wide variety of M&TE. This report describes the standards and calibrations laboratory.« less

  17. Flexible Educational Facilities. An Annotated Reference List.

    ERIC Educational Resources Information Center

    Wakefield, Howard E.

    These references on flexible educational facilities are abstracted by the ERIC Clearinghouse on Educational Facilities. College material includes an experimental learning center, a college health center, a fine arts center, and university library design. References on schools include secondary school design, flexible high school design, standard…

  18. 33 Shafts Category of Transuranic Waste Stored Below Ground within Area G

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hargis, Kenneth Marshall; Monk, Thomas H

    This report compiles information to support the evaluation of alternatives and analysis of regulatory paths forward for the 33 shafts. The historical information includes a form completed by waste generators for each waste package (Reference 6) that included a waste description, estimates of Pu-239 and uranium-235 (U-235) based on an accounting technique, and calculations of mixed fission products (MFP) based on radiation measurements. A 1979 letter and questionnaire (Reference 7) provides information on waste packaging of hot cell waste and the configuration of disposal shafts as storage in the 33 Shafts was initiated. Tables of data by waste package weremore » developed during a review of historical documents that was performed in 2005 (Reference 8). Radiological data was coupled with material-type data to estimate the initial isotopic content of each waste package and an Oak Ridge National Laboratory computer code was used to calculate 2009 decay levels. Other sources of information include a waste disposal logbook for the 33 shafts (Reference 9), reports that summarize remote-handled waste generated at the CMR facility (Reference 10) and placement of waste in the 33 shafts (Reference 11), a report on decommissioning of the LAMPRE reactor (Reference 12), interviews with an employee and manager involved in placing waste in the 33 shafts (References 13 and 14), an interview with a long-time LANL employee involved in waste operations (Reference 15), a 2002 plan for disposition of remote-handled TRU waste (Reference 16), and photographs obtained during field surveys of several shafts in 2007. The WIPP Central Characterization Project (CCP) completed an Acceptable Knowledge (AK) summary report for 16 canisters of remote-handled waste from the CMR Facility that contains information relevant to the 33 Shafts on hot-cell operations and timeline (Reference 17).« less

  19. 37 CFR 102.2 - Public reference facilities.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 37 Patents, Trademarks, and Copyrights 1 2011-07-01 2011-07-01 false Public reference facilities. 102.2 Section 102.2 Patents, Trademarks, and Copyrights UNITED STATES PATENT AND TRADEMARK OFFICE... thereto. The public reference facility is located in the Public Search Room, Madison Building East, First...

  20. 37 CFR 102.2 - Public reference facilities.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 37 Patents, Trademarks, and Copyrights 1 2014-07-01 2014-07-01 false Public reference facilities. 102.2 Section 102.2 Patents, Trademarks, and Copyrights UNITED STATES PATENT AND TRADEMARK OFFICE... thereto. The public reference facility is located in the Public Search Room, Madison Building East, First...

  1. 37 CFR 102.2 - Public reference facilities.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 37 Patents, Trademarks, and Copyrights 1 2013-07-01 2013-07-01 false Public reference facilities. 102.2 Section 102.2 Patents, Trademarks, and Copyrights UNITED STATES PATENT AND TRADEMARK OFFICE... thereto. The public reference facility is located in the Public Search Room, Madison Building East, First...

  2. 37 CFR 102.2 - Public reference facilities.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 37 Patents, Trademarks, and Copyrights 1 2012-07-01 2012-07-01 false Public reference facilities. 102.2 Section 102.2 Patents, Trademarks, and Copyrights UNITED STATES PATENT AND TRADEMARK OFFICE... thereto. The public reference facility is located in the Public Search Room, Madison Building East, First...

  3. 37 CFR 102.2 - Public reference facilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 37 Patents, Trademarks, and Copyrights 1 2010-07-01 2010-07-01 false Public reference facilities. 102.2 Section 102.2 Patents, Trademarks, and Copyrights UNITED STATES PATENT AND TRADEMARK OFFICE... thereto. The public reference facility is located in the Public Search Room, Madison Building East, First...

  4. Dosimetry measurements using Timepix in mixed radiation fields induced by heavy ions; comparison with standard dosimetry methods

    PubMed Central

    Ploc, Ondrej; Kubancak, Jan; Sihver, Lembit; Uchihori, Yukio; Jakubek, Jan; Ambrozova, Iva; Molokanov, Alexander; Pinsky, Lawrence

    2014-01-01

    Objective of our research was to explore capabilities of Timepix for its use as a single dosemeter and LET spectrometer in mixed radiation fields created by heavy ions. We exposed it to radiation field (i) at heavy ion beams at HIMAC, Chiba, Japan, (ii) in the CERN's high-energy reference field (CERF) facility at Geneva, France/Switzerland, (iii) in the exposure room of the proton therapy laboratory at JINR, Dubna, Russia, and (iv) onboard aircraft. We compared the absolute values of dosimetric quantities obtained with Timepix and with other dosemeters and spectrometers like tissue-equivalent proportional counter (TEPC) Hawk, silicon detector Liulin, and track-etched detectors (TEDs).

  5. 12 CFR 404.3 - Public reference facilities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 4 2010-01-01 2010-01-01 false Public reference facilities. 404.3 Section 404.3 Banks and Banking EXPORT-IMPORT BANK OF THE UNITED STATES INFORMATION DISCLOSURE Procedures for Disclosure of Records Under the Freedom of Information Act. § 404.3 Public reference facilities. Ex-Im Bank...

  6. 76 FR 9503 - Medicare and Medicaid Programs; Requirements for Long-Term Care (LTC) Facilities; Notice of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-18

    ... nursing facility (SNF) in the Medicare program, or a nursing facility (NF) in the Medicaid program. These..., as of April 2010, there are 15,713 long-term care (LTC) facilities (commonly referred to as nursing homes) in the U.S. LTC facilities are also referred to as skilled nursing facilities (SNFs) in the...

  7. ARM Climate Research Facility: Outreach Tools and Strategies

    NASA Astrophysics Data System (ADS)

    Roeder, L.; Jundt, R.

    2009-12-01

    Sponsored by the Department of Energy, the ARM Climate Research Facility is a global scientific user facility for the study of climate change. To publicize progress and achievements and to reach new users, the ACRF uses a variety of Web 2.0 tools and strategies that build off of the program’s comprehensive and well established News Center (www.arm.gov/news). These strategies include: an RSS subscription service for specific news categories; an email “newsletter” distribution to the user community that compiles the latest News Center updates into a short summary with links; and a Facebook page that pulls information from the News Center and links to relevant information in other online venues, including those of our collaborators. The ACRF also interacts with users through field campaign blogs, like Discovery Channel’s EarthLive, to share research experiences from the field. Increasingly, field campaign Wikis are established to help ACRF researchers collaborate during the planning and implementation phases of their field studies and include easy to use logs and image libraries to help record the campaigns. This vital reference information is used in developing outreach material that is shared in highlights, news, and Facebook. Other Web 2.0 tools that ACRF uses include Google Maps to help users visualize facility locations and aircraft flight patterns. Easy-to-use comment boxes are also available on many of the data-related web pages on www.arm.gov to encourage feedback. To provide additional opportunities for increased interaction with the public and user community, future Web 2.0 plans under consideration for ACRF include: evaluating field campaigns for Twitter and microblogging opportunities, adding public discussion forums to research highlight web pages, moving existing photos into albums on FlickR or Facebook, and building online video archives through YouTube.

  8. JPRS Report, Soviet Union, Political Affairs, Republic Language Legislation.

    DTIC Science & Technology

    1989-12-05

    reference materials ( dictionaries , termi- nology glossaries, phrase books, self-taught books, and so on), and qualified specialists in the field of...textbooks; d) to publish self-taught manuals, phrase books, and explanatory and bilingual dictionaries for the aid of persons desiring to study...Armenian. To create the nec- essary printing facility base to publish high-quality illus- trated dictionaries ; to provide uninterrupted delivery of

  9. Quantitative Estimation of Risks for Production Unit Based on OSHMS and Process Resilience

    NASA Astrophysics Data System (ADS)

    Nyambayar, D.; Koshijima, I.; Eguchi, H.

    2017-06-01

    Three principal elements in the production field of chemical/petrochemical industry are (i) Production Units, (ii) Production Plant Personnel and (iii) Production Support System (computer system introduced for improving productivity). Each principal element has production process resilience, i.e. a capability to restrain disruptive signals occurred in and out of the production field. In each principal element, risk assessment is indispensable for the production field. In a production facility, the occupational safety and health management system (Hereafter, referred to as OSHMS) has been introduced to reduce a risk of accidents and troubles that may occur during production. In OSHMS, a risk assessment is specified to reduce a potential risk in the production facility such as a factory, and PDCA activities are required for a continual improvement of safety production environments. However, there is no clear statement to adopt the OSHMS standard into the production field. This study introduces a metric to estimate the resilience of the production field by using the resilience generated by the production plant personnel and the result of the risk assessment in the production field. A method for evaluating how OSHMS functions are systematically installed in the production field is also discussed based on the resilience of the three principal elements.

  10. In-Situ Silver Acetylide Silver Nitrate Explosive Deposition Measurements Using X-Ray Fluorescence.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Covert, Timothy Todd

    2014-09-01

    The Light Initiated High Explosive facility utilized a spray deposited coating of silver acetylide - silver nitrate explosive to impart a mechanical shock into targets of interest. A diagnostic was required to measure the explosive deposition in - situ. An X - ray fluorescence spectrometer was deployed at the facility. A measurement methodology was developed to measure the explosive quantity with sufficient accuracy. Through the use of a tin reference material under the silver based explosive, a field calibration relationship has been developed with a standard deviation of 3.2 % . The effect of the inserted tin material into themore » experiment configuration has been explored.« less

  11. 40 CFR 160.47 - Facilities for handling test, control, and reference substances.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Facilities for handling test, control, and reference substances. 160.47 Section 160.47 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS GOOD LABORATORY PRACTICE STANDARDS Facilities § 160.47 Facilities...

  12. Challenges in Routine Implementation and Quality Control of Rapid Diagnostic Tests for Malaria–Rufiji District, Tanzania

    PubMed Central

    McMorrow, Meredith L.; Masanja, M. Irene; Abdulla, Salim M. K.; Kahigwa, Elizeus; Kachur, S. Patrick

    2018-01-01

    Rapid diagnostic tests (RDTs) represent an alternative to microscopy for malaria diagnosis and have shown high sensitivity and specificity in a variety of study settings. Current World Health Organization (WHO) guidelines for quality control of RDTs provide detailed instructions on pre-field testing, but offer little guidance for quality assurance once RDTs are deployed in health facilities. From September 2006 to April 2007, we introduced a histidine-rich protein II (HRP2)-based RDT (Paracheck) for suspected malaria cases five years of age and older in nine health facilities in Rufiji District, Tanzania, to assess sensitivity and specificity of RDTs in routine use at rural health facilities. Thick blood smears were collected for all patients tested with RDTs and stained and read by laboratory personnel in each facility. Thick smears were subsequently reviewed by a reference microscopist to determine RDT sensitivity and specificity. In all nine health facilities, there were significant problems with the quality of staining and microscopy. Sensitivity and specificity of RDTs were difficult to assess given the poor quality of routine blood smear staining. Mean operational sensitivity of RDTs based on reference microscopy was 64.8%, but varied greatly by health facility, range 18.8–85.9%. Sensitivity of RDTs increased with increasing parasite density. Specificity remained high at 87.8% despite relatively poor slide quality. Institution of quality control of RDTs based on poor quality blood smear staining may impede reliable measurement of sensitivity and specificity and undermine confidence in the new diagnostic. There is an urgent need for the development of alternative quality control procedures for rapid diagnostic tests that can be performed at the facility level. PMID:18784230

  13. NASA low-speed centrifugal compressor for 3-D viscous code assessment and fundamental flow physics research

    NASA Technical Reports Server (NTRS)

    Hathaway, M. D.; Wood, J. R.; Wasserbauer, C. A.

    1991-01-01

    A low speed centrifugal compressor facility recently built by the NASA Lewis Research Center is described. The purpose of this facility is to obtain detailed flow field measurements for computational fluid dynamic code assessment and flow physics modeling in support of Army and NASA efforts to advance small gas turbine engine technology. The facility is heavily instrumented with pressure and temperature probes, both in the stationary and rotating frames of reference, and has provisions for flow visualization and laser velocimetry. The facility will accommodate rotational speeds to 2400 rpm and is rated at pressures to 1.25 atm. The initial compressor stage being tested is geometrically and dynamically representative of modern high-performance centrifugal compressor stages with the exception of Mach number levels. Preliminary experimental investigations of inlet and exit flow uniformly and measurement repeatability are presented. These results demonstrate the high quality of the data which may be expected from this facility. The significance of synergism between computational fluid dynamic analysis and experimentation throughout the development of the low speed centrifugal compressor facility is demonstrated.

  14. Analysis of LNG peakshaving-facility release-prevention systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pelto, P.J.; Baker, E.G.; Powers, T.B.

    1982-05-01

    The purpose of this study is to provide an analysis of release prevention systems for a reference LNG peakshaving facility. An overview assessment of the reference peakshaving facility, which preceeded this effort, identified 14 release scenarios which are typical of the potential hazards involved in the operation of LNG peakshaving facilities. These scenarios formed the basis for this more detailed study. Failure modes and effects analysis and fault tree analysis were used to estimate the expected frequency of each release scenario for the reference peakshaving facility. In addition, the effectiveness of release prevention, release detection, and release control systems weremore » evaluated.« less

  15. Factors related to the decision-making for moving the older adults into long-term care facilities in Taiwan.

    PubMed

    Hsieh, Yen-Ping; Huang, Ying-Chia; Lan, Shou-Jen; Ho, Ching-Sung

    2017-09-01

    To investigate the relationships between demographic characteristics of the elderly, type of long-term care (LTC) facilities, and the reasons for moving into LTC facilities. Research participants included people aged over 65 years, living in LTC facilities. A total of 1280 questionnaires were distributed to 111 LTC facilities in Taiwan; 480 questionnaires were retrieved, and 232 were included in the valid sample. The study used a non-linear canonical correlation analysis, which assesses the relationships among similar sets of categorical variables. The results showed that the older adults in quadrant I were characterized by being involved in the decision-making regarding the choice of LTC facilities and received economic support from their children. The older adults in quadrant II mainly lived in LTC facilities to receive medical care, whereas those in quadrant III typically included individuals with low income, who did not choose to live in LTC facilities. Furthermore, those in quadrant IV had positive cognitions associated with LTC facilities. We believe that the results of the present study will facilitate policy-making in the field of LTC, provide reference to the practitioners and the older adults, and identify the types of decisions older adults make when moving into LTC facilities, thus assisting older adults to improve their strategies regarding staying in LTC facilities. Geriatr Gerontol Int 2017; 17: 1319-1327. © 2016 Japan Geriatrics Society.

  16. Monte Carlo study of a 60Co calibration field of the Dosimetry Laboratory Seibersdorf.

    PubMed

    Hranitzky, C; Stadtmann, H

    2007-01-01

    The gamma radiation fields of the reference irradiation facility of the Dosimetry Laboratory Seibersdorf with collimated beam geometry are used for calibrating radiation protection dosemeters. A close-to-reality simulation model of the facility including the complex geometry of a 60Co source was set up using the Monte Carlo code MCNP. The goal of this study is to characterise the radionuclide gamma calibration field and resulting air-kerma distributions inside the measurement hall with a total of 20 m in length. For the whole range of source-detector-distances (SDD) along the central beam axis, simulated and measured relative air-kerma values are within +/-0.6%. Influences on the accuracy of the simulation results are investigated, including e.g., source mass density effects or detector volume dependencies. A constant scatter contribution from the lead ring-collimator of approximately 1% and an increasing scatter contribution from the concrete floor for distances above 7 m are identified, resulting in a total air-kerma scatter contribution below 5%, which is in accordance to the ISO 4037-1 recommendations.

  17. NASA's future plans for space astronomy and astrophysics

    NASA Technical Reports Server (NTRS)

    Kaplan, Michael S.

    1992-01-01

    NASA's plans in the field of space astronomy and astrophysics through the first decade of the next century are reviewed with reference to specific missions and mission concepts. The missions discussed include the Space Infrared Telescope Facility, the Stratospheric Observatory for Infrared Astronomy, the Submillimeter Intermediate Mission, the Astrometric Interferometry Mission, the Greater Observatories program, and Mission from Planet Earth. Plans to develop optics and sensors technology to enable these missions are also discussed.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    LaFreniere, L. M.

    The Commodity Credit Corporation (CCC), an agency of the U.S. Department of Agriculture (USDA), operated grain storage facilities at two different locations at Everest, Kansas (Figure 1.1). One facility (referred to in this report as the Everest facility) was at the western edge of the city of Everest. The CCC/USDA operated this facility from 1950 until the early 1970s. The second facility (referred to in this report as Everest East) was about 0.5 mi northeast of the town. The CCC/USDA operated this facility from 1954 until the early 1970s. While these two former CCC/USDA grain storage facilities were in operation,more » commercial grain fumigants containing carbon tetrachloride were in common use by the CCC/USDA and the private grain storage industry to preserve grain. In 1997, the Kansas Department of Health and Environment (KDHE) sampled several domestic drinking water and nondrinking water wells in the Everest area. The KDHE sampling was part of the CCC/USDA Private Well Sampling Program, which was initiated to determine whether carbon tetrachloride was present in domestic wells near former CCC/USDA grain storage facilities in Kansas. All of the sampled domestic drinking water wells were located outside the Everest city boundaries. As a result of this sampling, carbon tetrachloride contamination was identified at a single domestic drinking water well (the Nigh well; DW06) approximately 3/8 mi northwest of the former Everest CCC/USDA grain storage facility. The CCC/USDA subsequently connected the Nigh residence to the Everest municipal water system. As a result of the detection of carbon tetrachloride in this well, the KDHE conducted preliminary investigations to further evaluate the existence of contamination and its potential effect on public health and the environment. The KDHE concluded that carbon tetrachloride in groundwater at Everest might, in part, be linked to historical use of carbon tetrachloride-based grain fumigants at the former CCC/USDA facilities. For this reason, the CCC/USDA is conducting an environmental site investigation to determine the source(s) and extent of the carbon tetrachloride contamination at Everest and to assess whether the contamination requires remedial action. The investigation at Everest is being performed by the Environmental Research Division of Argonne National Laboratory. Argonne is a nonprofit, multidisciplinary research center operated by the University of Chicago for the U.S. Department of Energy (DOE). The CCC/USDA has entered into an interagency agreement with DOE, under which Argonne provides technical assistance to the CCC/USDA with environmental site characterization and remediation at its former grain storage facilities. At these facilities, Argonne is applying its QuickSite{reg_sign} environmental site characterization methodology. This methodology has been applied successfully at a number of former CCC/USDA facilities in Kansas and Nebraska and has been adopted by the American Society for Testing and Materials (ASTM 1998) as standard practice for environmental site characterization. Phase I of the QuickSite{reg_sign} investigation examined the key geologic, hydrogeologic, and hydrogeochemical relationships that define potential contaminant migration pathways at Everest (Argonne 2001). Phase II of the QuickSite{reg_sign} investigation at Everest was undertaken with the primary goal of delineating and improving understanding of the distribution of carbon tetrachloride contamination in groundwater at this site and the potential source area(s) that might have contributed to this contamination. To address this goal, four specific technical objectives were developed to guide the Phase II field studies. Sampling of near-surface soils at the former Everest CCC/USDA facility that was originally planned for Phase I had to be postponed until October 2000 because of access restrictions. Viable vegetation was not available for sampling then. This period is termed the first session of Phase II field work at Everest. The main session of field work for the Phase II QuickSite{reg_sign} investigation of the Everest site began on March 6, 2001. Work was suspended at the site on April 6, 2001, (1) because of access limitations to key properties, located north and west of the former CCC/USDA facility, imposed by the private owners at the onset of the spring planting season and (2) to permit further documentation by Argonne, at the request of the CCC/USDA, of the land use and ownership history of the Nigh property as a precursor to completion of the field work. This period is termed the second session of Phase II field work at Everest. Investigation of the Nigh property history was prompted by groundwater contamination evidence obtained during the second session of Phase II field activities (discussed in Section 3.7).« less

  19. Quality Assurance of Rapid Diagnostic Tests for Malaria in Routine Patient Care in Rural Tanzania

    PubMed Central

    McMorrow, Meredith L.; Masanja, M. Irene; Kahigwa, Elizeus; Abdulla, Salim M. K.; Kachur, S. Patrick

    2010-01-01

    Histidine-rich protein II (HRP2)-based malaria rapid diagnostic tests (RDTs) have shown high sensitivity and specificity for detecting Plasmodium falciparum malaria in a variety of study settings. However, RDTs are susceptible to heat and humidity and variation in individual performance, which may affect their use in field settings. We evaluated sensitivity and specificity of RDTs during routine use for malaria case management in peripheral health facilities. From December 2007 to October 2008, HRP2-based ParaHIT-f RDTs were introduced in 12 facilities without available microscopy in Rufiji District, Tanzania. Health workers received a single day of instruction on how to perform an RDT and thick blood smear. Job aids, Integrated Management of Childhood Illness guidelines, and national malaria treatment algorithms were reviewed. For quality assurance (QA), thick blood smears for reference microscopy were collected for 2 to 3 days per week from patients receiving RDTs; microscopy was not routinely performed at the health facilities. Slides were stained and read centrally within 72 hours of collection by a reference microscopist. When RDT and blood smear results were discordant, blood smears were read by additional reference microscopists blinded to earlier results. Facilities were supervised monthly by the district laboratory supervisor or a member of the study team. Ten thousand six hundred fifty (10,650) patients were tested with RDTs, and 51.5% (5,488/10,650) had a positive test result. Blood smear results were available for 3,914 patients, of whom 40.1% (1,577/3,914) were positive for P. falciparum malaria. Overall RDT sensitivity was 90.7% (range by facility 85.7–96.5%) and specificity was 73.5% (range 50.0–84.3%). Sensitivity increased with increasing parasite density. Successful implementation of RDTs was achieved in peripheral health facilities with adequate training and supervision. Quality assurance is essential to the adequate performance of any laboratory test. Centralized staining and reading of blood smears provided useful monitoring of RDT performance. However, this level of QA may not be sustainable nationwide. PMID:20065013

  20. 40 CFR 792.47 - Facilities for handling test, control, and reference substances.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 31 2010-07-01 2010-07-01 true Facilities for handling test, control, and reference substances. 792.47 Section 792.47 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT (CONTINUED) GOOD LABORATORY PRACTICE STANDARDS Facilities...

  1. Science Facilities Bibliography.

    ERIC Educational Resources Information Center

    National Science Foundation, Washington, DC.

    A bibliographic collection on science buildings and facilities is cited with many different reference sources for those concerned with the design, planning, and layout of science facilities. References are given covering a broad scope of information on--(1) physical plant planning, (2) management and safety, (3) building type studies, (4) design…

  2. Pedestrian and bicycle facilities in California : a technical reference and technology transfer synthesis for Caltrans planners and engineers.

    DOT National Transportation Integrated Search

    2005-07-01

    The primary purpose of Pedestrian and Bicycle Facilities in CaliforniaA : Technical Reference and Technology Transfer Synthesis for Caltrans Planners : and Engineers (Technical Reference) is to provide Caltrans staff : with a synthesis of in...

  3. 29 CFR 504.1 - Cross-reference.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... FACILITIES USING NONIMMIGRANT ALIENS AS REGISTERED NURSES § 504.1 Cross-reference. Regulations governing labor condition attestations by facilities using nonimmigrant aliens as registered nurses are found at...

  4. 29 CFR 504.1 - Cross-reference.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... FACILITIES USING NONIMMIGRANT ALIENS AS REGISTERED NURSES § 504.1 Cross-reference. Regulations governing labor condition attestations by facilities using nonimmigrant aliens as registered nurses are found at...

  5. A Bonner Sphere Spectrometer with extended response matrix

    NASA Astrophysics Data System (ADS)

    Birattari, C.; Dimovasili, E.; Mitaroff, A.; Silari, M.

    2010-08-01

    This paper describes the design, calibration and applications at high-energy accelerators of an extended-range Bonner Sphere neutron Spectrometer (BSS). The BSS was designed by the FLUKA Monte Carlo code, investigating several combinations of materials and diameters of the moderators for the high-energy channels. The system was calibrated at PTB in Braunschweig, Germany, using monoenergetic neutron beams in the energy range 144 keV-19 MeV. It was subsequently tested with Am-Be source neutrons and in the simulated workplace neutron field at CERF (the CERN-EU high-energy reference field facility). Since 2002, it has been employed for neutron spectral measurements around CERN accelerators.

  6. Benchmark studies of induced radioactivity produced in LHC materials, Part I: Specific activities.

    PubMed

    Brugger, M; Khater, H; Mayer, S; Prinz, A; Roesler, S; Ulrici, L; Vincke, H

    2005-01-01

    Samples of materials which will be used in the LHC machine for shielding and construction components were irradiated in the stray radiation field of the CERN-EU high-energy reference field facility. After irradiation, the specific activities induced in the various samples were analysed with a high-precision gamma spectrometer at various cooling times, allowing identification of isotopes with a wide range of half-lives. Furthermore, the irradiation experiment was simulated in detail with the FLUKA Monte Carlo code. A comparison of measured and calculated specific activities shows good agreement, supporting the use of FLUKA for estimating the level of induced activity in the LHC.

  7. The 1970/71 spectral data management programs

    NASA Technical Reports Server (NTRS)

    Marshall, A. A.

    1971-01-01

    The data management programs used by the Stanford Remote Sensing Laboratory to access, modify, and reduce the data obtained from both the NASA IR airborne spectrometer, and Stanford's SG-4 field spectrometer are reported. Many details covered in previous reports are not repeated. References are provided. These programs are written in FORTRAN 4 and S/360 Assembler Language, and are currently running on a S/360 model 67 (operating under OS/MFT) at the Stanford Computation Center Campus Facility.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goldsmith, John

    High Spectral Resolution Lidar (HSRL) systems provide vertical profiles of optical depth, backscatter cross-section, depolarization, and backscatter phase function. All HSRL measurements are absolutely calibrated by reference to molecular scattering, which is measured at each point in the lidar profile. Like the Raman lidar but unlike simple backscatter lidars such as the micropulse lidar, the HSRL can measure backscatter cross-sections and optical depths without prior assumptions about the scattering properties of the atmosphere. The depolarization observations also allow robust discrimination between ice and water clouds. In addition, rigorous error estimates can be computed for all measurements. A very narrow, angularmore » field of view reduces multiple scattering contributions. The small field of view, coupled with a narrow optical bandwidth, nearly eliminates noise due to scattered sunlight. There are two operational U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility HSRL systems, one at the Barrow North Slope of Alaska (NSA) site and the other in the second ARM Mobile Facility (AMF2) collection of instrumentation.« less

  9. D 2 and D-T Liquid-Layer Target Shots at the National Ignition Facility

    DOE PAGES

    Walters, Curtis; Alger, Ethan; Bhandarkar, Suhas; ...

    2018-01-19

    Experiments at the National Ignition Facility (NIF) using targets containing a deuterium-tritium (D-T) fuel layer have, until recently, required that a high-quality layer of solid D-T (herein referred to as an ice layer) be formed in the capsule. The development of a process to line the inner surface of a target capsule with a foam layer of a thickness that is typical of ice layers has resulted in the ability to field targets with liquid layers wetting the foam. Successful fielding of liquid-layer targets on NIF required not only a foam-lined capsule but also changes to the capsule filling processmore » and the manner with which the inventory is maintained in the capsule. Additionally, changes to target heater power and the temperature drops across target components were required in order to achieve the desired range of shot temperatures. Finally, these changes and the target’s performance during four target shots on NIF are discussed.« less

  10. D 2 and D-T Liquid-Layer Target Shots at the National Ignition Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walters, Curtis; Alger, Ethan; Bhandarkar, Suhas

    Experiments at the National Ignition Facility (NIF) using targets containing a deuterium-tritium (D-T) fuel layer have, until recently, required that a high-quality layer of solid D-T (herein referred to as an ice layer) be formed in the capsule. The development of a process to line the inner surface of a target capsule with a foam layer of a thickness that is typical of ice layers has resulted in the ability to field targets with liquid layers wetting the foam. Successful fielding of liquid-layer targets on NIF required not only a foam-lined capsule but also changes to the capsule filling processmore » and the manner with which the inventory is maintained in the capsule. Additionally, changes to target heater power and the temperature drops across target components were required in order to achieve the desired range of shot temperatures. Finally, these changes and the target’s performance during four target shots on NIF are discussed.« less

  11. Capsule review of the DOE research and development and field facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    1980-09-01

    A description is given of the roles of DOE's headquarters, field offices, major multiprogram laboratories, Energy Technology and Mining Technology Centers, and other government-owned, contractor-operated facilities, which are located in all regions of the US. Descriptions of DOE facilities are given for multiprogram laboratories (12); program-dedicated facilities (biomedical and environmental facilities-12, fossil energy facilities-7, fusion energy facility-1, nuclear development facilities-3, physical research facilities-4, safeguards facility-1, and solar facilities-2); and Production, Testing, and Fabrication Facilities (nuclear materials production facilities-5, weapon testing and fabrication complex-8). Three appendices list DOE field and project offices; DOE field facilities by state or territory, names, addresses,more » and telephone numbers; DOE R and D field facilities by type, contractor names, and names of directors. (MCW)« less

  12. 40 CFR 792.47 - Facilities for handling test, control, and reference substances.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 32 2014-07-01 2014-07-01 false Facilities for handling test, control... § 792.47 Facilities for handling test, control, and reference substances. (a) As necessary to prevent contamination or mixups, there shall be separate areas for: (1) Receipt and storage of the test, control, and...

  13. 40 CFR 792.47 - Facilities for handling test, control, and reference substances.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 32 2011-07-01 2011-07-01 false Facilities for handling test, control... § 792.47 Facilities for handling test, control, and reference substances. (a) As necessary to prevent contamination or mixups, there shall be separate areas for: (1) Receipt and storage of the test, control, and...

  14. 40 CFR 792.47 - Facilities for handling test, control, and reference substances.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 33 2013-07-01 2013-07-01 false Facilities for handling test, control... § 792.47 Facilities for handling test, control, and reference substances. (a) As necessary to prevent contamination or mixups, there shall be separate areas for: (1) Receipt and storage of the test, control, and...

  15. 40 CFR 792.47 - Facilities for handling test, control, and reference substances.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 33 2012-07-01 2012-07-01 false Facilities for handling test, control... § 792.47 Facilities for handling test, control, and reference substances. (a) As necessary to prevent contamination or mixups, there shall be separate areas for: (1) Receipt and storage of the test, control, and...

  16. Evaluation of Gas-filled Ionization Chamber Method for Radon Measurement at Two Reference Facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ishikawa, Tetsuo; Tokonami, Shinji; Kobayashi, Yosuke

    2008-08-07

    For quality assurance, gas-filled ionization chamber method was tested at two reference facilities for radon calibration: EML (USA) and PTB (Germany). Consequently, the radon concentrations estimated by the ionization chamber method were in good agreement with the reference radon concentrations provided by EML as well as PTB.

  17. NIF ICCS network design and loading analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tietbohl, G; Bryant, R

    The National Ignition Facility (NIF) is housed within a large facility about the size of two football fields. The Integrated Computer Control System (ICCS) is distributed throughout this facility and requires the integration of about 40,000 control points and over 500 video sources. This integration is provided by approximately 700 control computers distributed throughout the NIF facility and a network that provides the communication infrastructure. A main control room houses a set of seven computer consoles providing operator access and control of the various distributed front-end processors (FEPs). There are also remote workstations distributed within the facility that allow providemore » operator console functions while personnel are testing and troubleshooting throughout the facility. The operator workstations communicate with the FEPs which implement the localized control and monitoring functions. There are different types of FEPs for the various subsystems being controlled. This report describes the design of the NIF ICCS network and how it meets the traffic loads that will are expected and the requirements of the Sub-System Design Requirements (SSDR's). This document supersedes the earlier reports entitled Analysis of the National Ignition Facility Network, dated November 6, 1996 and The National Ignition Facility Digital Video and Control Network, dated July 9, 1996. For an overview of the ICCS, refer to the document NIF Integrated Computer Controls System Description (NIF-3738).« less

  18. Walkthrough screening evaluation field guide. Natural phenomena hazards at Department of Energy facilities: Revision 2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eder, S.J.; Eli, M.W.; Salmon, M.W.

    1993-11-01

    The US Department of Energy (DOE) has a large inventory of existing facilities. Many of these facilities were not designed and constructed to current natural phenomena hazard (NPH) criteria. The NPH events include earthquakes, extreme winds and tornadoes, and floods. DOE Order 5480.28 establishes policy and requirements for NPH mitigation for DOE facilities. DOE is conducting a multiyear project to develop evaluation guidelines for assessing the condition and determining the need for upgrades at DOE facilities. One element of the NPH evaluation guidelines` development involves the existing systems and components at DOE facilities. This effort is described in detail inmore » a cited reference. In the interim period prior to availability of the final guidelines, DOE facilities are encouraged to implement an NPH walk through screening evaluation process by which systems and components that need attention can be rapidly identified. Guidelines for conducting the walk through screening evaluations are contained herein. The result of the NPH walk through screening evaluation should be a prioritized list of systems and components that need further action. Simple and inexpensive fixes for items identified in the walk through as marginal or inadequate should be implemented without further study. By implementing an NPH walk through screening evaluation, DOE facilities may realize significant reduction in risk from NPH in the short term.« less

  19. SU-E-T-195: Commissioning the Neutron Production of a Varian TrueBeam Linac

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Irazola, L; Brualla, L; Rosello, J

    2015-06-15

    Purpose: The purpose of this work is the characterization of a new Varian TrueBeam™ facility in terms of neutron production, in order to estimate neutron equivalent dose in organs during radiotherapy treatments. Methods: The existing methodology [1] was used with the reference SRAMnd detector, calibrated in terms of thermal neutron fluence at the reference field operated by PTB (Physikalisch-Technische-Bundesanstalt) at the GeNF (Geesthacht-Neutron-Facility) with the GKSS reactor FRG-1 [2]. Thermal neutron fluence for the 5 available possibilities was evaluated: 15 MV and 10&6 MV with and without Flattening Filter (FF and FFF, respectively). Irradiation conditions are as described in [3].more » In addition, three different collimator-MLC configurations were studied for 15 MV: (a) collimator of 10×10 cm{sup 2} and MLC fully retracted (reference), (b) field sizes of 20×20 cm{sup 2} and 10×10 cm{sup 2} for collimator and MLC respectively, and (c) collimator and MLC aperture of 10×10 cm{sup 2}. Results: Thermal fluence rate at the “reference point” [3], as a consequence of the neutron production, obtained for (a) conformation in 15 MV is (1.45±0.11) x10{sup 4} n•cm{sup 2}/MU. Configurations (b) and (c) gave fluences of 96.6% and 97.8% of the reference (a). Neutron production decreases up to 8.6% and 5.7% for the 10 MV FF and FFF beams, respectively. Finally, it decreases up to 2.8% and 0.1% for the 6 MV FF and FFF modes, respectively. Conclusion: This work evaluates thermal neutron production of Varian TrueBeam™ system for organ equivalent dose estimation. The small difference in collimator-MLC configuration shows the universality of the methodology [3]. A decrease in this production is shown when decreasing energy from 15 to 10 MV and an almost negligible production was found for 6 MV. Moreover, a lower neutron contribution is observed for the FFF modes.[1]Phys Med Biol,2012;57:6167–6191.[2]Radiat Meas,2010;45:1513–1517.[3]Med Phys,2015;42:276–281.« less

  20. Life sciences space station planning document: A reference payload for the exobiology research facilities

    NASA Technical Reports Server (NTRS)

    1987-01-01

    The Cosmic Dust Collection and Gas Grain Simulation Facilities represent collaborative efforts between the Life Sciences and Solar System Exploration Divisions designed to strengthen a natural exobiology/Planetary Sciences connection. The Cosmic Dust Collection Facility is a Planetary Science facility, with Exobiology a primary user. Conversely, the Gas Grain Facility is an exobiology facility, with Planetary Science a primary user. Requirements for the construction and operation of the two facilities, contained herein, were developed through joint workshops between the two disciplines, as were representative experiments comprising the reference payloads. In the case of the Gas Grain Simulation Facility, the astrophysics Division is an additional potential user, having participated in the workshop to select experiments and define requirements.

  1. Low turbulence/high efficiency cyclone separators: Facility qualification results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Razgaitis, R.; Paul, D.D.; Bioarski, A.A.

    1985-01-01

    The objective of this work is to experimentally investigate the near-wall turbulent flow-fields characteristic of cyclone separators in order to determine the influence of wall-originating turbulence on the separation of fine particles. In particular, seven turbulence suppression concepts will be evaluated with reference to a well-established baseline condition. Concepts which appear attractive will be studied and characterized in more detail. The work accomplished to date is principally the design, construction, and qualification of two of the facilities that will be used to study the various concepts of turbulence suppression. The qualification of the primary facility, the Cyclonic Wind Tunnel (CWT),more » has required the development and adaptation of laser Doppler velocimetry (LDV) to perform simultaneous two-dimensional turbulence measurements in a highly swirling flow. A companion facility to the CWT is the Curvilinear Boundary Layer (CBL) apparatus. The purpose of the CBL is to provide a thick, visually-observable near-wall flow region under dynamically similar conditions to the CWT to that a physical understanding of the turbulence suppression process can be obtained. 9 refs., 15 figs.« less

  2. KWFC: four square degrees camera for the Kiso Schmidt Telescope

    NASA Astrophysics Data System (ADS)

    Sako, Shigeyuki; Aoki, Tsutomu; Doi, Mamoru; Ienaka, Nobuyuki; Kobayashi, Naoto; Matsunaga, Noriyuki; Mito, Hiroyuki; Miyata, Takashi; Morokuma, Tomoki; Nakada, Yoshikazu; Soyano, Takao; Tarusawa, Ken'ichi; Miyazaki, Satoshi; Nakata, Fumiaki; Okada, Norio; Sarugaku, Yuki; Richmond, Michael W.

    2012-09-01

    The Kiso Wide Field Camera (KWFC) is a facility instrument for the 105-cm Schmidt telescope being operated by the Kiso Observatory of the University of Tokyo. This camera has been designed for wide-field observations by taking advantage of a large focal-plane area of the Schmidt telescope. Eight CCD chips with a total of 8k x 8k pixels cover a field-of-view of 2.2 degrees x 2.2 degrees on the sky. The dewar window works as a field flattener lens minimizing an image distortion across the field of view. Two shutter plates moving in parallel achieve uniform exposures on all the CCD pixels. The KWFC is equipped with a filter exchanger composed of an industrial robotic arm, a filter magazine capable of storing 12 filters, and a filter holder at the focal plane. Both the arm and the magazine are installed inside the tube framework of the telescope but without vignetting the beam. Wide-field survey programs searching for supernovae and late-type variable stars have begun in April 2012. The survey observations are performed with a management software system for facility instruments including the telescope and the KWFC. This system automatically carries out observations based on target lists registered in advance and makes appropriate decisions for implementation of observations by referring to weather conditions and status of the instruments. Image data obtained in the surveys are processed with pipeline software in real time to search for candidates of time-variable sources.

  3. Performance of active feedforward control systems in non-ideal, synthesized diffuse sound fields.

    PubMed

    Misol, Malte; Bloch, Christian; Monner, Hans Peter; Sinapius, Michael

    2014-04-01

    The acoustic performance of passive or active panel structures is usually tested in sound transmission loss facilities. A reverberant sending room, equipped with one or a number of independent sound sources, is used to generate a diffuse sound field excitation which acts as a disturbance source on the structure under investigation. The spatial correlation and coherence of such a synthesized non-ideal diffuse-sound-field excitation, however, might deviate significantly from the ideal case. This has consequences for the operation of an active feedforward control system which heavily relies on the acquisition of coherent disturbance source information. This work, therefore, evaluates the spatial correlation and coherence of ideal and non-ideal diffuse sound fields and considers the implications on the performance of a feedforward control system. The system under consideration is an aircraft-typical double panel system, equipped with an active sidewall panel (lining), which is realized in a transmission loss facility. Experimental results for different numbers of sound sources in the reverberation room are compared to simulation results of a comparable generic double panel system excited by an ideal diffuse sound field. It is shown that the number of statistically independent noise sources acting on the primary structure of the double panel system depends not only on the type of diffuse sound field but also on the sample lengths of the processed signals. The experimental results show that the number of reference sensors required for a defined control performance exhibits an inverse relationship to control filter length.

  4. Measuring physical activity environments: a brief history.

    PubMed

    Sallis, James F

    2009-04-01

    Physical activity is usually done in specific types of places, referred to as physical activity environments. These often include parks, trails, fitness centers, schools, and streets. In recent years, scientific interest has increased notably in measuring physical activity environments. The present paper provides an historical overview of the contributions of the health, planning, and leisure studies fields to the development of contemporary measures. The emphasis is on attributes of the built environment that can be affected by policies to contribute to the promotion of physical activity. Researchers from health fields assessed a wide variety of built environment variables expected to be related to recreational physical activity. Settings of interest were schools, workplaces, and recreation facilities, and most early measures used direct observation methods with demonstrated inter-observer reliability. Investigators from the city planning field evaluated aspects of community design expected to be related to people's ability to walk from homes to destinations. GIS was used to assess walkability defined by the 3Ds of residential density, land-use diversity, and pedestrian-oriented designs. Evaluating measures for reliability or validity was rarely done in the planning-related fields. Researchers in the leisure studies and recreation fields studied mainly people's use of leisure time rather than physical characteristics of parks and other recreation facilities. Although few measures of physical activity environments were developed, measures of aesthetic qualities are available. Each of these fields made unique contributions to the contemporary methods used to assess physical activity environments.

  5. The effect of referral and transfer patients on hospital funding in a capitated health care delivery system.

    PubMed

    Pietz, Kenneth; Byrne, Margaret M; Daw, Christina; Petersen, Laura A

    2007-10-01

    (1) To investigate whether inpatients referred or transferred between facilities result in increased financial loss compared with those admitted directly, in a health care delivery system funded by capitation methods. (2) To determine whether the higher cost of those patients transferred or referred is fairly compensated by a diagnosis-based risk adjustment system, and whether tertiary care facilities bear an unfair financial burden for such patients in a capitated financing environment. The study cohort included all Veterans Affairs (VA) beneficiaries who received inpatient care during fiscal year (FY) 2004. Referral was defined as an outpatient visit to 1 facility followed by an admission to another facility. Transfers were consecutive inpatient stays at different hospitals. We defined loss as cost minus the share of budget determined by a Diagnostic Cost Group-based allocation. Both t tests and linear regression were used to compare the effect on cost and loss for patients transferred or not and referred or not. Mean loss to a facility for patients transferred in was 1231 dollars more than for those not transferred. Mean loss for referred patients was 3341 dollars more than for those not referred, controlling for disease burden. For tertiary hospitals, the difference in losses for transfer patients was less than for other hospitals but greater for referral patients. Patients referred or transferred from other facilities are more costly than those who are not. The difference may not be compensated by a diagnosis-based allocation system. A capitated health care system may consider additional funding to cover the cost of such patients.

  6. Comparison of Different Measurement Technologies for the In-Flight Assessment of Radiated Acoustic Intensity

    NASA Technical Reports Server (NTRS)

    Klos, Jacob; Palumbo, Daniel L.; Buehrle, Ralph D.; Williams, Earl G.; Valdivia, Nicolas; Herdic, Peter C.; Sklanka, Bernard

    2005-01-01

    A series of tests was planned and conducted in the Interior Noise Test Facility at Boeing Field, on the NASA Aries 757 flight research aircraft, and in the Structural Acoustic Loads and Transmission Facility at NASA Langley Research Center. These tests were designed to answer several questions concerning the use of array methods in flight. One focus of the tests was determining whether and to what extent array methods could be used to identify the effects of an acoustical treatment applied to a limited portion of an aircraft fuselage. Another focus of the tests was to verify that the arrays could be used to localize and quantify a known source purposely placed in front of the arrays. Thus the issues related to backside sources and flanking paths present in the complicated sound field were addressed during these tests. These issues were addressed through the use of reference transducers, both accelerometers mounted to the fuselage and microphones in the cabin, that were used to correlate the pressure holograms. measured by the microphone arrays using either SVD methods or partial coherence methods. This correlation analysis accepts only energy that is coherent with the sources sensed by the reference transducers, allowing a noise control engineer to only identify and study those vibratory sources of interest. The remainder of this paper will present a detailed description of the test setups that were used in this test sequence and typical results of the NAH/IBEM analysis used to reconstruct the sound fields. Also, a comparison of data obtained in the laboratory environments and during flights of the 757 aircraft will be made.

  7. Characterization of the ITER CS conductor and projection to the ITER CS performance

    DOE PAGES

    Martovetsky, N.; Isono, T.; Bessette, D.; ...

    2017-06-20

    The ITER Central Solenoid (CS) is one of the critical elements of the machine. The CS conductor went through an intense optimization and qualification program, which included characterization of the strands, a conductor straight short sample testing in the SULTAN facility at the Swiss Plasma Center (SPC), Villigen, Switzerland, and a single-layer CS Insert coil recently tested in the Central Solenoid Model Coil (CSMC) facility in QST-Naka, Japan. In this paper, we obtained valuable data in a wide range of the parameters (current, magnetic field, temperature, and strain), which allowed a credible characterization of the CS conductor in different conditions.more » Finally, using this characterization, we will make a projection to the performance of the CS in the ITER reference scenario.« less

  8. Characterization of the ITER CS conductor and projection to the ITER CS performance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martovetsky, N.; Isono, T.; Bessette, D.

    The ITER Central Solenoid (CS) is one of the critical elements of the machine. The CS conductor went through an intense optimization and qualification program, which included characterization of the strands, a conductor straight short sample testing in the SULTAN facility at the Swiss Plasma Center (SPC), Villigen, Switzerland, and a single-layer CS Insert coil recently tested in the Central Solenoid Model Coil (CSMC) facility in QST-Naka, Japan. In this paper, we obtained valuable data in a wide range of the parameters (current, magnetic field, temperature, and strain), which allowed a credible characterization of the CS conductor in different conditions.more » Finally, using this characterization, we will make a projection to the performance of the CS in the ITER reference scenario.« less

  9. Site maps and facilities listings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1993-11-01

    In September 1989, a Memorandum of Agreement among DOE offices regarding the environmental management of DOE facilities was signed by appropriate Assistant Secretaries and Directors. This Memorandum of Agreement established the criteria for EM line responsibility. It stated that EM would be responsible for all DOE facilities, operations, or sites (1) that have been assigned to DOE for environmental restoration and serve or will serve no future production need; (2) that are used for the storage, treatment, or disposal of hazardous, radioactive, and mixed hazardous waste materials that have been properly characterized, packaged, and labelled, but are not used formore » production; (3) that have been formally transferred to EM by another DOE office for the purpose of environmental restoration and the eventual return to service as a DOE production facility; or (4) that are used exclusively for long-term storage of DOE waste material and are not actively used for production, with the exception of facilities, operations, or sites under the direction of the DOE Office of Civilian Radioactive Waste Management. As part of the implementation of the Memorandum of Agreement, Field Offices within DOE submitted their listings of facilities, systems, operation, and sites for which EM would have line responsibility. It is intended that EM facility listings will be revised on a yearly basis so that managers at all levels will have a valid reference for the planning, programming, budgeting and execution of EM activities.« less

  10. Consumer Choice Between Hospital-Based and Freestanding Facilities for Arthroscopy: Impact on Prices, Spending, and Surgical Complications.

    PubMed

    Robinson, James C; Brown, Timothy T; Whaley, Christopher; Bozic, Kevin J

    2015-09-16

    Hospital-based outpatient departments traditionally charge higher prices for ambulatory procedures, compared with freestanding surgery centers. Under emerging reference-based benefit designs, insurers establish a contribution limit that they will pay, requiring the patient to pay the difference between that contribution limit and the actual price charged by the facility. The purpose of this study was to evaluate the impact of reference-based benefits on consumer choices, facility prices, employer spending, and surgical outcomes for orthopaedic procedures performed at ambulatory surgery centers. We obtained data on 3962 patients covered by the California Public Employees' Retirement System (CalPERS) who underwent arthroscopy of the knee or shoulder in the three years prior to the implementation of reference-based benefits in January 2012 and on 2505 patients covered by CalPERS who underwent arthroscopy in the two years after implementation. Control group data were obtained on 57,791 patients who underwent arthroscopy and were not subject to reference-based benefits. The impact of reference-based benefits on consumer choices between hospital-based and freestanding facilities, facility prices, employer spending, and surgical complications was assessed with use of difference-in-differences multivariable regressions to adjust for patient demographic characteristics, comorbidities, and geographic location. By the second year of the program, the shift to reference-based benefits was associated with an increase in the utilization of freestanding ambulatory surgery centers by 14.3 percentage points (95% confidence interval, 8.1 to 20.5 percentage points) for knee arthroscopy and by 9.9 percentage points (95% confidence interval, 3.2 to 16.7 percentage points) for shoulder arthroscopy and a corresponding decrease in the use of hospital-based facilities. The mean price paid by CalPERS fell by 17.6% (95% confidence interval, -24.9% to -9.6%) for knee procedures and by 17.0% (95% confidence interval, -29.3% to -2.5%) for shoulder procedures. The shift to reference-based benefits was not associated with a change in the rate of surgical complications. In the first two years after the implementation of reference-based benefits, CalPERS saved $2.3 million (13%) on these two orthopaedic procedures. Reference-based benefits increase consumer sensitivity to price differences between freestanding and hospital-based surgical facilities. This study shows that the implementation of reference-based benefits does not result in a significant increase in measured complication rates for those subject to reference-based benefits. Copyright © 2015 by The Journal of Bone and Joint Surgery, Incorporated.

  11. Consumer Choice Between Hospital-Based and Freestanding Facilities for Arthroscopy

    PubMed Central

    Robinson, James C.; Brown, Timothy T.; Whaley, Christopher; Bozic, Kevin J.

    2015-01-01

    Background: Hospital-based outpatient departments traditionally charge higher prices for ambulatory procedures, compared with freestanding surgery centers. Under emerging reference-based benefit designs, insurers establish a contribution limit that they will pay, requiring the patient to pay the difference between that contribution limit and the actual price charged by the facility. The purpose of this study was to evaluate the impact of reference-based benefits on consumer choices, facility prices, employer spending, and surgical outcomes for orthopaedic procedures performed at ambulatory surgery centers. Methods: We obtained data on 3962 patients covered by the California Public Employees’ Retirement System (CalPERS) who underwent arthroscopy of the knee or shoulder in the three years prior to the implementation of reference-based benefits in January 2012 and on 2505 patients covered by CalPERS who underwent arthroscopy in the two years after implementation. Control group data were obtained on 57,791 patients who underwent arthroscopy and were not subject to reference-based benefits. The impact of reference-based benefits on consumer choices between hospital-based and freestanding facilities, facility prices, employer spending, and surgical complications was assessed with use of difference-in-differences multivariable regressions to adjust for patient demographic characteristics, comorbidities, and geographic location. Results: By the second year of the program, the shift to reference-based benefits was associated with an increase in the utilization of freestanding ambulatory surgery centers by 14.3 percentage points (95% confidence interval, 8.1 to 20.5 percentage points) for knee arthroscopy and by 9.9 percentage points (95% confidence interval, 3.2 to 16.7 percentage points) for shoulder arthroscopy and a corresponding decrease in the use of hospital-based facilities. The mean price paid by CalPERS fell by 17.6% (95% confidence interval, −24.9% to −9.6%) for knee procedures and by 17.0% (95% confidence interval, −29.3% to −2.5%) for shoulder procedures. The shift to reference-based benefits was not associated with a change in the rate of surgical complications. In the first two years after the implementation of reference-based benefits, CalPERS saved $2.3 million (13%) on these two orthopaedic procedures. Conclusions: Reference-based benefits increase consumer sensitivity to price differences between freestanding and hospital-based surgical facilities. Clinical Relevance: This study shows that the implementation of reference-based benefits does not result in a significant increase in measured complication rates for those subject to reference-based benefits. PMID:26378263

  12. Estimating the cost of referral and willingness to pay for referral to higher-level health facilities: a case series study from an integrated community case management programme in Uganda.

    PubMed

    Nanyonjo, Agnes; Bagorogoza, Benson; Kasteng, Frida; Ayebale, Godfrey; Makumbi, Fredrick; Tomson, Göran; Källander, Karin

    2015-08-28

    Integrated community case management (iCCM) relies on community health workers (CHWs) managing children with malaria, pneumonia, diarrhoea, and referring children when management is not possible. This study sought to establish the cost per sick child referred to seek care from a higher-level health facility by a CHW and to estimate caregivers' willingness to pay (WTP) for referral. Caregivers of 203 randomly selected children referred to higher-level health facilities by CHWs were interviewed in four Midwestern Uganda districts. Questionnaires and document reviews were used to capture direct, indirect and opportunity costs incurred by caregivers, CHWs and health facilities managing referred children. WTP for referral was assessed through the 'bidding game' approach followed by an open-ended question on maximum WTP. Descriptive analysis was conducted for factors associated with referral completion and WTP using logistic and linear regression methods, respectively. The cost per case referred to higher-level health facilities was computed from a societal perspective. Reasons for referral included having fever with a negative malaria test (46.8%), danger signs (29.6%) and drug shortage (37.4%). Among the referred, less than half completed referral (45.8%). Referral completion was 2.8 times higher among children with danger signs (p = 0.004) relative to those without danger signs, and 0.27 times lower among children who received pre-referral treatment (p < 0.001). The average cost per case referred was US$ 4.89 and US$7.35 per case completing referral. For each unit cost per case referred, caregiver out of pocket expenditure contributed 33.7%, caregivers' and CHWs' opportunity costs contributed 29.2% and 5.1% respectively and health facility costs contributed 39.6%. The mean (SD) out of pocket expenditure was US$1.65 (3.25). The mean WTP for referral was US$8.25 (14.70) and was positively associated with having received pre-referral treatment, completing referral and increasing caregiver education level. The mean WTP for referral was higher than the average out of pocket expenditure. This, along with suboptimal referral completion, points to barriers in access to higher-level facilities as the primary cause of low referral. Community mobilisation for uptake of referral is necessary if the policy of referring children to the nearest health facility is to be effective.

  13. Using mobile phones to ensure that referred tuberculosis patients reach their treatment facilities: a call that makes a difference.

    PubMed

    Choun, Kimcheng; Achanta, Shanta; Naik, Balaji; Tripathy, Jaya Prasad; Thai, Sopheak; Lorent, Natalie; Khun, Kim Eam; van Griensven, Johan; Kumar, Ajay M V; Zachariah, Rony

    2017-08-22

    Over the last decade, the availability and use of mobile phones have grown exponentially globally and in Cambodia. In the Sihanouk Hospital Centre of Hope(SHCH) in Cambodia about half of all tuberculosis patients referred out to peripheral health facilities for TB treatment initiation or continuation were lost to contact after referral ranging from 19 to 69% between 2008 and 2013. To address this, we implemented a mobile phone-based patient tracking intervention. Here, we report the number and proportion of referred TB patients who could be contacted through a mobile phone and retained in care after the introduction of mobile phone tracking. A descriptive study involving follow-up of TB patients referred out from SHCH to peripheral health facilities during May-October 2014. Standard operating procedures were used to contact individual patients and/or health facilities using a mobile phone. Among 109 TB patients referred to peripheral health facilities, 107(98%) had access to a mobile phone of whom, 103(97%) could be contacted directly while 5(2%) were contacted through their health care providers. A total of 108(99%) of 109 referred TB patients in intervention period were thus placed on TB treatment. This study provides preliminary, but promising evidence that using mobile phones was accompanied with improved retention of referred TB patients compared to historical cohorts. Given the limitations associated with historical controls, we need better designed studies with larger sample size to strengthen the evidence before national scale-up.

  14. Francis Bitter National Magnet Laboratory annual report, July 1990 through June 1991

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1991-06-01

    The contents include: reports on laboratory research programs--magneto-optics and semiconductor physics, magnetism, superconductivity, solid state nuclear magnetic resonance, condensed matter chemistry, biomagnetism, magnet technology, instrumentation, molecular biophysics; reports of visiting scientists--reports of users of the high magnetic field facility, reports of users of the pulsed field facility, reports of users of the SQUID magnetometer and Mossbauer facility, reports of users of the high field NMR facility; appendices--publications and meeting speeches, organization, summary of high magnetic field facility use, user tables, geographic distribution of high magnetic field facility users, summary of educational activities.

  15. Francis Bitter National Magnet Laboratory annual report, July 1989 through June 1990

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1990-01-01

    Contents: Reports on laboratory research programs: Magneto-optics and semiconductor physics, Magnetism, Superconductivity, Solid state nuclear magnetic resonance, Condensed matter chemistry, Biomagnetism, Magnet technology, Molecular biophysics; Reports of visiting scientists: Reports of users of the High Magnetic Field Facility, Reports of users of the pulsed field facility, Reports of users of the squid magnetometer and Mossbauer facility, Reports of users of the high field NMR facility; Appendices: Publications and meeting speeches, Organization, Summary of high magnetic field facility use, User tables, Geographic distribution of high magnetic field facility users, Summary of educational activities.

  16. Design and Shielding of Radiotherapy Treatment Facilities; IPEM Report 75, 2nd Edition

    NASA Astrophysics Data System (ADS)

    Horton, Patrick; Eaton, David

    2017-07-01

    Design and Shielding of Radiotherapy Treatment Facilities provides readers with a single point of reference for protection advice to the construction and modification of radiotherapy facilities. The book assembles a faculty of national and international experts on all modalities including megavoltage and kilovoltage photons, brachytherapy and high-energy particles, and on conventional and Monte Carlo shielding calculations. This book is a comprehensive reference for qualified experts and radiation-shielding designers in radiation physics and also useful to anyone involved in the design of radiotherapy facilities.

  17. 77 FR 31841 - Notice of Applications for Authorization To Abandon Facilities and Services and To Acquire...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-30

    ... To Abandon Facilities and Services and To Acquire Facilities by Merger Steuben Gas Storage Company... Field Storage Facilities (Adrian Field) which Steuben operates pursuant to certificates of public... authorization to charge market based rates following its acquisition of the Adrian Field Storage Facility. The...

  18. Facilities maintenance handbook

    NASA Technical Reports Server (NTRS)

    1991-01-01

    This handbook is a guide for facilities maintenance managers. Its objective is to set minimum facilities maintenance standards. It also provides recommendations on how to meet the standards to ensure that NASA maintains its facilities in a manner that protects and preserves its investment in the facilities in a cost-effective manner while safely and efficiently performing its mission. This handbook implements NMI 8831.1, which states NASA facilities maintenance policy and assigns organizational responsibilities for the management of facilities maintenance activities on all properties under NASA jurisdiction. It is a reference for facilities maintenance managers, not a step-by-step procedural manual. Because of the differences in NASA Field Installation organizations, this handbook does not assume or recommend a typical facilities maintenance organization. Instead, it uses a systems approach to describe the functions that should be included in any facilities maintenance management system, regardless of its organizational structure. For documents referenced in the handbook, the most recent version of the documents is applicable. This handbook is divided into three parts: Part 1 specifies common definitions and facilities maintenance requirements and amplifies the policy requirements contained in NMI 8831. 1; Part 2 provides guidance on how to meet the requirements of Part 1, containing recommendations only; Part 3 contains general facilities maintenance information. One objective of this handbook is to fix commonality of facilities maintenance definitions among the Centers. This will permit the application of uniform measures of facilities conditions, of the relationship between current replacement value and maintenance resources required, and of the backlog of deferred facilities maintenance. The utilization of facilities maintenance system functions will allow the Centers to quantitatively define maintenance objectives in common terms, prepare work plans, and develop management information in order to statistically identify and analyze variances from those plans. It will also add credibility to the NASA facilities maintenance budgeting process. The key to a successful maintenance program is the understanding and support of the senior Center managers.

  19. A Field Study of Air Force Organization Structures.

    DTIC Science & Technology

    1984-05-01

    t.ral 1z,,- contract . 66-1 and 66-5 are the numbered regulations ... eo coer’. , of design. Contract refers to the design used in a facility where...REPORT NUMBER (S) 5 MONITORING ORGANIZATION RLPORT NuMHLF1H’ LMDC-TR-34-4 6& NAME OF PERFORMING ORGANIZATION Fr. O IE SYMBOL 7a NAME OF MONITORING ORGANIZA...assi f ied 22& NAME OF RESPONSIBLE IN0IVIO~jA. 22t, TELEPHONE NUMBER 22c OFF ICE SY(MBOL Capt Jeffrey S. Austin (0)2373 MCA DOD FORM 1473,83 APR

  20. International Microgravity Plasma Facility IMPF: A Multi-User Modular Research Facility for Complex Plasma Research on ISS

    NASA Astrophysics Data System (ADS)

    Seurig, R.; Burfeindt, J.; Castegini, R.; Griethe, W.; Hofmann, P.

    2002-01-01

    On March 03, 2001, the PKE-Nefedov plasma experiment was successfully put into operation on board ISS. This complex plasma experiment is the predecessor for the semi-autonomous multi-user facility IMPF (International Microgravity Plasma Facility) to be flown in 2006 with an expected operational lifetime of 10 years. IMPF is envisioned to be an international research facility for investigators in the field of multi-component plasmas containing ions, electrons, and charged microparticles. This research filed is often referred to as "complex plasmas". The actual location of IMPF on ISS is not decided yet; potential infrastructure under consideration are EXPRESS Rack, Standard Interface Rack SIR, European Drawer Rack EDR, or a to be designed custom rack infrastructure on the Russian Segment. The actual development status of the DLR funded Pre-phase B Study for IMPF will be presented. For this phase, IMPF was assumed to be integrated in an EXPRESS Rack requiring four middeck lockers with two 4-PU ISIS drawers for accommodation. Technical and operational challenges, like a 240 Mbytes/sec continuous experimental data stream for 60 minutes, will be addressed. The project was funded by the German Space Agency (DLR) and was performed in close cooperation with scientists from the Max-Planck-Institute for Extraterrestical Physics in Munich, Germany.

  1. Dutch Dataset Pain Rehabilitation in daily practice: Content, patient characteristics and reference data.

    PubMed

    Köke, A J A; Smeets, R J E M; Schreurs, K M; van Baalen, B; de Haan, P; Remerie, S C; Schiphorst Preuper, H R; Reneman, M F

    2017-03-01

    No core set of measurement tools exists to collect data within clinical practice. Such data could be useful as reference data to guide treatment decisions and to compare patient characteristics or treatment results within specific treatment settings. The Dutch Dataset Pain Rehabilitation was developed which included the six domains of the IMMPACT core set and three new domains relevant in the field of rehabilitation (medical consumption, patient-specific goals and activities/participation). Between 2010 and 2013 the core set was implemented in 32 rehabilitation facilities throughout the Netherlands. A total of 8200 adult patients with chronic pain completed the core set at first consultation with the rehabilitation physician. Adult patients (18-90 years) suffering from a long history of pain (38% >5 years) were referred. Patients had high medical consumption and less than half were working. Although patients were referred with diagnosis of low back pain or neck or shoulder pain, a large group (85%) had multisite pain (39% 2-5 painful body regions; 46% >5 painful body regions). Scores on psychosocial questionnaires were high, indicating high case complexity of referred patients. Reference data for subgroups based on gender, pain severity, pain locations and on pain duration are presented. The data from this clinical core set can be used to compare patient characteristics of patients of other treatment setting and/or scientific publications. As treatment success might depend on case complexity, which is high in the referred patients, the advantages of earlier referral to comprehensive multidisciplinary treatment were discussed. A detailed description of case complexity of patients with chronic pain referred for pain rehabilitation. Insight in case complexity of patients within subgroups on the basis of gender, pain duration, pain severity and pain location. These descriptions can be used as reference data for daily practice in the field of pain rehabilitation and can be used to evaluate, monitor and improve rehabilitation care in care settings nationwide as well as internationally. © 2016 European Pain Federation - EFIC®.

  2. Gains in efficiency and scientific potential of continental climate reconstruction provided by the LRC LacCore Facility, University of Minnesota

    NASA Astrophysics Data System (ADS)

    Noren, A.; Brady, K.; Myrbo, A.; Ito, E.

    2007-12-01

    Lacustrine sediment cores comprise an integral archive for the determination of continental paleoclimate, for their potentially high temporal resolution and for their ability to resolve spatial variability in climate across vast sections of the globe. Researchers studying these archives now have a large, nationally-funded, public facility dedicated to the support of their efforts. The LRC LacCore Facility, funded by NSF and the University of Minnesota, provides free or low-cost assistance to any portion of research projects, depending on the specific needs of the project. A large collection of field equipment (site survey equipment, coring devices, boats/platforms, water sampling devices) for nearly any lacustrine setting is available for rental, and Livingstone-type corers and drive rods may be purchased. LacCore staff can accompany field expeditions to operate these devices and curate samples, or provide training prior to device rental. The Facility maintains strong connections to experienced shipping agents and customs brokers, which vastly improves transport and importation of samples. In the lab, high-end instrumentation (e.g., multisensor loggers, high-resolution digital linescan cameras) provides a baseline of fundamental analyses before any sample material is consumed. LacCore staff provide support and training in lithological description, including smear-slide, XRD, and SEM analyses. The LRC botanical macrofossil reference collection is a valuable resource for both core description and detailed macrofossil analysis. Dedicated equipment and space for various subsample analyses streamlines these endeavors; subsamples for several analyses may be submitted for preparation or analysis by Facility technicians for a fee (e.g., carbon and sulfur coulometry, grain size, pollen sample preparation and analysis, charcoal, biogenic silica, LOI, freeze drying). The National Lacustrine Core Repository now curates ~9km of sediment cores from expeditions around the world, and stores metadata and analytical data for all cores processed at the facility. Any researcher may submit sample requests for material in archived cores. Supplies for field (e.g., polycarbonate pipe, endcaps), lab (e.g., sample containers, pollen sample spike), and curation (e.g., D-tubes) are sold at cost. In collaboration with facility users, staff continually develop new equipment, supplies, and procedures as needed in order to provide the best and most comprehensive set of services to the research community.

  3. Rotating pressure measurement system using an on board calibration standard

    NASA Technical Reports Server (NTRS)

    Senyitko, Richard G.; Blumenthal, Philip Z.; Freedman, Robert J.

    1991-01-01

    A computer-controlled multichannel pressure measurement system was developed to acquire detailed flow field measurements on board the Large Low Speed Centrifugal Compressor Research Facility at the NASA Lewis Research Center. A pneumatic slip ring seal assembly is used to transfer calibration pressures to a reference standard transducer on board the compressor rotor in order to measure very low differential pressures with the high accuracy required. A unique data acquisition system was designed and built to convert the analog signal from the reference transducer to the variable frequency required by the multichannel pressure measurement system and also to provide an output for temperature control of the reference transducer. The system also monitors changes in test cell barometric pressure and rotating seal leakage and provides an on screen warning to the operator if limits are exceeded. The methods used for the selection and testing of the the reference transducer are discussed, and the data acquisition system hardware and software design are described. The calculated and experimental data for the system measurement accuracy are also presented.

  4. Chlorine measurements at the 5MV French AMS national facility ASTER: Associated external uncertainties and comparability with the 6MV DREAMS facility

    NASA Astrophysics Data System (ADS)

    Braucher, R.; Keddadouche, K.; Aumaître, G.; Bourlès, D. L.; Arnold, M.; Pivot, S.; Baroni, M.; Scharf, A.; Rugel, G.; Bard, E.

    2018-04-01

    After 6 years of 36Cl routine operation, more than 6000 unknown samples have been measured at the 5MV French accelerator mass spectrometry (AMS) national facility ASTER (CEREGE, Aix en Provence). This paper presents the long term behavior of ASTER through the analysis of the measurements of the most used chlorine standards and reference materials, KNSTD1600, SM-Cl-12 and SM-CL-13 over a 46 months' time period. Comparison of measured chlorine concentrations (both 35Cl and 36Cl) from ice samples on two AMS facilities operating at 5MV (ASTER) and 6MV (DREAMS, Helmholtz-Zentrum Dresden-Rossendorf) and normalizing to two different reference materials agree within uncertainties making both reference materials (SM-Cl-12 and KNSTD1600) suitable for 36Cl measurement at ASTER.

  5. Libraries & Study Facilities. A Selected Bibliography.

    ERIC Educational Resources Information Center

    Wisconsin Univ., Madison. ERIC Clearinghouse on Educational Facilities.

    This bibliography contains a selected reference list of publications of interest to architects, library planners, and librarians contemplating the planning, programing, and/or design of library facilities. Each reference is followed by a listing of ERIC descriptors that describe its contents. The items are listed in six sections: (1) library…

  6. 40 CFR 160.47 - Facilities for handling test, control, and reference substances.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... the test systems and shall be adequate to preserve the identity, strength, purity, and stability of... 40 Protection of Environment 24 2011-07-01 2011-07-01 false Facilities for handling test, control... for handling test, control, and reference substances. (a) As necessary to prevent contamination or...

  7. 40 CFR 160.47 - Facilities for handling test, control, and reference substances.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... the test systems and shall be adequate to preserve the identity, strength, purity, and stability of... 40 Protection of Environment 25 2013-07-01 2013-07-01 false Facilities for handling test, control... for handling test, control, and reference substances. (a) As necessary to prevent contamination or...

  8. 40 CFR 160.47 - Facilities for handling test, control, and reference substances.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... the test systems and shall be adequate to preserve the identity, strength, purity, and stability of... 40 Protection of Environment 24 2014-07-01 2014-07-01 false Facilities for handling test, control... for handling test, control, and reference substances. (a) As necessary to prevent contamination or...

  9. 40 CFR 160.47 - Facilities for handling test, control, and reference substances.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... the test systems and shall be adequate to preserve the identity, strength, purity, and stability of... 40 Protection of Environment 25 2012-07-01 2012-07-01 false Facilities for handling test, control... for handling test, control, and reference substances. (a) As necessary to prevent contamination or...

  10. 77 FR 2829 - Energy Conservation Program: Test Procedure for Television Sets

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-19

    ... provisions designed to improve energy efficiency. (All references to EPCA refer to the statute as amended... also provides that the test procedure shall be reasonably designed to produce test results which... facility one is denoted with numerical values, while the data from test facility two is denoted with...

  11. 36 CFR 1281.2 - What publications are incorporated by reference?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 36 Parks, Forests, and Public Property 3 2012-07-01 2012-07-01 false What publications are incorporated by reference? 1281.2 Section 1281.2 Parks, Forests, and Public Property NATIONAL ARCHIVES AND RECORDS ADMINISTRATION NARA FACILITIES PRESIDENTIAL LIBRARY FACILITIES § 1281.2 What publications are...

  12. 5 CFR 1631.4 - Public reference facilities and current index.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... index. 1631.4 Section 1631.4 Administrative Personnel FEDERAL RETIREMENT THRIFT INVESTMENT BOARD AVAILABILITY OF RECORDS Production or Disclosure of Records Under the Freedom of Information Act, 5 U.S.C. 552 § 1631.4 Public reference facilities and current index. (a) The Board maintains a public reading area...

  13. A 2D ion chamber array audit of wedged and asymmetric fields in an inhomogeneous lung phantom.

    PubMed

    Lye, Jessica; Kenny, John; Lehmann, Joerg; Dunn, Leon; Kron, Tomas; Alves, Andrew; Cole, Andrew; Williams, Ivan

    2014-10-01

    The Australian Clinical Dosimetry Service (ACDS) has implemented a new method of a nonreference condition Level II type dosimetric audit of radiotherapy services to increase measurement accuracy and patient safety within Australia. The aim of this work is to describe the methodology, tolerances, and outcomes from the new audit. The ACDS Level II audit measures the dose delivered in 2D planes using an ionization chamber based array positioned at multiple depths. Measurements are made in rectilinear homogeneous and inhomogeneous phantoms composed of slabs of solid water and lung. Computer generated computed tomography data sets of the rectilinear phantoms are supplied to the facility prior to audit for planning of a range of cases including reference fields, asymmetric fields, and wedged fields. The audit assesses 3D planning with 6 MV photons with a static (zero degree) gantry. Scoring is performed using local dose differences between the planned and measured dose within 80% of the field width. The overall audit result is determined by the maximum dose difference over all scoring points, cases, and planes. Pass (Optimal Level) is defined as maximum dose difference ≤3.3%, Pass (Action Level) is ≤5.0%, and Fail (Out of Tolerance) is >5.0%. At close of 2013, the ACDS had performed 24 Level II audits. 63% of the audits passed, 33% failed, and the remaining audit was not assessable. Of the 15 audits that passed, 3 were at Pass (Action Level). The high fail rate is largely due to a systemic issue with modeling asymmetric 60° wedges which caused a delivered overdose of 5%-8%. The ACDS has implemented a nonreference condition Level II type audit, based on ion chamber 2D array measurements in an inhomogeneous slab phantom. The powerful diagnostic ability of this audit has allowed the ACDS to rigorously test the treatment planning systems implemented in Australian radiotherapy facilities. Recommendations from audits have led to facilities modifying clinical practice and changing planning protocols.

  14. Francis bitter national magnet laboratory annual report, July 1991 through June 1992

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-06-01

    ;Contents: Reports on Laboratory Research Programs--Magneto-Optics and Semiconductor Physics, Superconductivity and Magnetism, Solid State Nuclear Magnetic Resonance, Condensed Matter Chemistry, Biomagnetism, Magnet Technology, Instrumentation, Molecular Biophysics, Carbon Filters and Fullerenes; Reports of Visiting Scientists--Reports of Users of the High Magnetic Field Facility, Reports of the Users of the Pulsed Field Facility, Reports of the Users of the High Field NMR Facility; Appendices--Publications and Meeting Speeches, Organization, Summary of High Magnetic Field Facility Use--January 1, 1984 through June 30, 1992, Geographic Distribution of High Magnetic Field Facility Users (Excluding FBNML Staff), Summary of Educational Activities.

  15. Francis Bitter National Magnet Laboratory annual report, July 1988 through June 1989

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1989-01-01

    Contents include: reports on laboratory research programs--magneto-optics and semiconductor physics, magnetism, superconductivity, solid-state nuclear magnetic resonance, condensed-matter chemistry, biomagnetism, magnet technology, instrumentation for high-magnetic-field research, molecular biophysics; reports of visiting scientists--reports of users of the High Magnetic Field Facility, reports of users of the Pulsed Field Facility, reports of users of the SQUID Magnetometer and Moessbauer Facility, reports of users of the High-Field NMR Facility; Appendices--publications and meeting speeches, organization, summary of High-Field Magnet Facility use January 1, 1981 through December 31, 1988; geographic distribution of High-Field Magnet users (excluding laboratory staff); and summary of educational activities.

  16. 7 CFR 1493.200 - General statement.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... OF AGRICULTURE EXPORT PROGRAMS CCC EXPORT CREDIT GUARANTEE PROGRAMS CCC Facility Guarantee Program... (CCC) Facility Guarantee Program (FGP). CCC will issue facility payment guarantees for project... so, will be incorporated by reference on the face of the facility payment guarantee issued by CCC. ...

  17. 7 CFR 1493.200 - General statement.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... OF AGRICULTURE EXPORT PROGRAMS CCC EXPORT CREDIT GUARANTEE PROGRAMS CCC Facility Guarantee Program... (CCC) Facility Guarantee Program (FGP). CCC will issue facility payment guarantees for project... so, will be incorporated by reference on the face of the facility payment guarantee issued by CCC. ...

  18. 7 CFR 1493.200 - General statement.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... OF AGRICULTURE EXPORT PROGRAMS CCC EXPORT CREDIT GUARANTEE PROGRAMS CCC Facility Guarantee Program... (CCC) Facility Guarantee Program (FGP). CCC will issue facility payment guarantees for project... so, will be incorporated by reference on the face of the facility payment guarantee issued by CCC. ...

  19. GALACSI system design and analysis

    NASA Astrophysics Data System (ADS)

    Ströbele, S.; La Penna, P.; Arsenault, R.; Conzelmann, R. D.; Delabre, B.; Duchateau, M.; Dorn, R.; Fedrigo, E.; Hubin, N.; Quentin, J.; Jolley, P.; Kiekebusch, M.; Kirchbauer, J. P.; Klein, B.; Kolb, J.; Kuntschner, H.; Le Louarn, M.; Lizon, J. L.; Madec, P.-Y.; Pettazzi, L.; Soenke, C.; Tordo, S.; Vernet, J.; Muradore, R.

    2012-07-01

    GALACSI is one of the Adaptive Optics (AO) systems part of the ESO Adaptive Optics Facility (AOF). It will use the VLT 4-Laser Guide Stars system, high speed and low noise WaveFront Sensor cameras (<1e-, 1000Hz) the Deformable Secondary Mirror (DSM) and the SPARTA Real Time Computer to sharpen images and enhance faint object detectability of the MUSE Instrument. MUSE is an Integral Field Spectrograph working at wavelengths from 465nm to 930nm. GALACSI implements 2 different AO modes; in Wide Field Mode (WFM) it will perform Ground Layer AO correction and enhance the collected energy in a 0.2" by 0.2" pixel by a factor 2 at 750nm over a Field of View (FoV) of 1' by 1'. The 4 LGSs and one tip tilt reference star (R-mag <17.5) are located outside the MUSE FoV. Key requirements are to provide this performance and a very good image stability for a 1hour long integration time. In Narrow Field Mode (NFM) Laser Tomography AO will be used to reconstruct and correct the turbulence for the center field using the 4 LGSs at 15" off axis and the Near Infra Red (NIR) light of one reference star on axis for tip tilt and focus sensing. In NFM GALACSI will provide a moderate Strehl Ratio of 5% (goal 10%) at 650nm. The NFM hosts several challenges and many subsystems will be pushed to their limits. The opto mechanical design and error budgets of GALACSI is described here.

  20. 36 CFR § 1281.2 - What publications are incorporated by reference?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 36 Parks, Forests, and Public Property 3 2013-07-01 2012-07-01 true What publications are incorporated by reference? § 1281.2 Section § 1281.2 Parks, Forests, and Public Property NATIONAL ARCHIVES AND RECORDS ADMINISTRATION NARA FACILITIES PRESIDENTIAL LIBRARY FACILITIES § 1281.2 What publications...

  1. The Role of a National Biocontainment Laboratory in Emergencies.

    PubMed

    Le Duc, James W; Ksiazek, Thomas G

    2015-01-01

    Over a decade ago, the National Institutes of Health awarded partial support for the construction and operation of 2 National Biocontainment Laboratories, with the condition that they would be available to assist in the event of public health emergencies-although how a biocontainment facility located on an academic campus might contribute was not defined. Here we offer examples of how one of these laboratories has contributed to a coordinated response to 2 recent international public health emergencies. Essential assets for success include highly trained and experienced staff, access to reference pathogens and reagents, cutting-edge knowledge of the field, appropriate biocontainment facilities, robust biosafety and biosecurity programs, and availability of modern instrumentation. The ability to marry the strengths of academia in basic and applied research with access to appropriate biocontainment facilities while drawing on a highly skilled cadre of experienced experts has proven extremely valuable in the response to recent national emergencies and will continue to do so in the future. Areas where additional planning and preparation are needed have also been identified through these experiences.

  2. Association of Reference Payment for Colonoscopy With Consumer Choices, Insurer Spending, and Procedural Complications.

    PubMed

    Robinson, James C; Brown, Timothy T; Whaley, Christopher; Finlayson, Emily

    2015-11-01

    Regulatory limits on consumer cost sharing permit wide variation in the prices charged for screening and diagnostic tests such as colonoscopy. Employers are experimenting with reference payment initiatives that offer full insurance coverage at low-priced facilities but require substantial cost sharing if patients select high-priced alternatives. To ascertain the effect of reference payment on facility choice, insurer spending, consumer cost sharing, and procedural complications for colonoscopy. The California Public Employees' Retirement System (CalPERS) implemented reference payment in January 2012. We obtained data on 21 644 CalPERS enrollees who underwent colonoscopy in the 3 years prior to implementation and on 13 551 patients in the 2 years after implementation. Control group data were obtained on 258 616 Anthem Blue Cross enrollees who underwent colonoscopy and who were not subject to reference payment initiatives during this 5-year period. Consumer choice of facility, price paid per procedure, total insurer spending, consumer cost sharing, and procedural complications. Choices, prices, and complications were compared for CalPERS and Anthem patients before and after implementation of reference payments, using difference-in-difference multivariable regressions to adjust for patient demographic characteristics and comorbidities, procedure indications, and geographic location. Utilization of low-priced facilities for CalPERS members increased from 68.6% in 2009 to 90.5% in 2013. After adjusting for patient demographic characteristics, comorbidities, and other factors, the implementation of reference payment increased use of low-priced facilities by 17.6 percentage points (95% CI, 11.8 to 23.4; P < .001). The mean price paid for colonoscopy for the CalPERS population increased from $1587 (95% CI, $1555-$1618) in 2009 to $1716 (95% CI, $1678-$1753) in 2011 and then decreased to $1508 (95% CI, $1469-$1548) in 2013 for patients subject to reference payment. After adjustment for other relevant factors, reference payment was responsible for a 21.0% (95% CI, -26.0% to -15.6%, P < .001) reduction in the price. Reference payment was associated with a small but statistically insignificant decline in procedural complications, from 2.1% in 2009 to 2.0% in 2013 (P = .47). In the first 2 years after implementation, CalPERS saved $7.0 million (28%) on spending for the procedure. Implementation of reference payment for colonoscopy was associated with reduced spending and no change in complications.

  3. Power Lander for Support of Long-Term Lunar Presence

    NASA Technical Reports Server (NTRS)

    Joyner, Russ; Rodriguez, Gary

    2004-01-01

    Emerging industrial base and the consequent sustained manned Lunar presence will require consistent high power capacities. This paper proposes a first iteration design of a flyable electric power platform which could serve as an enabler of Lunar Development and Exploration. It is intended to support a small facility solo or an emerging industrial base as part of a grid. Lunar Missions, Habitats and Facilities stand to benefit from an expected decade of non-stop operation, the economics of scale, Commercial Off-The-Shelf (COTS) availability, standardization of design, and logistical support for Lunar encampments provided by this architecture. The unattended and unmanned vehicle design is to be man- and robotics-serviceable after delivery by current and proposed heavy-lift boosters. Design continuity within a family of systems will improve reliability through "lessons learned'' in the field. Further, various configurations of the proposed scalable architecture will provide reference platforms for the indigenous construction of similar power plant facilities from in-situ Lunar resources (ISRU). The baseline design should be directed towards those materials available on the Moon and expected to be manufacturable on-site within the first decade of operation.

  4. Computer-Aided Facilities Management Systems (CAFM).

    ERIC Educational Resources Information Center

    Cyros, Kreon L.

    Computer-aided facilities management (CAFM) refers to a collection of software used with increasing frequency by facilities managers. The six major CAFM components are discussed with respect to their usefulness and popularity in facilities management applications: (1) computer-aided design; (2) computer-aided engineering; (3) decision support…

  5. A global reference for caesarean section rates (C-Model): a multicountry cross-sectional study.

    PubMed

    Souza, J P; Betran, A P; Dumont, A; de Mucio, B; Gibbs Pickens, C M; Deneux-Tharaux, C; Ortiz-Panozo, E; Sullivan, E; Ota, E; Togoobaatar, G; Carroli, G; Knight, H; Zhang, J; Cecatti, J G; Vogel, J P; Jayaratne, K; Leal, M C; Gissler, M; Morisaki, N; Lack, N; Oladapo, O T; Tunçalp, Ö; Lumbiganon, P; Mori, R; Quintana, S; Costa Passos, A D; Marcolin, A C; Zongo, A; Blondel, B; Hernández, B; Hogue, C J; Prunet, C; Landman, C; Ochir, C; Cuesta, C; Pileggi-Castro, C; Walker, D; Alves, D; Abalos, E; Moises, Ecd; Vieira, E M; Duarte, G; Perdona, G; Gurol-Urganci, I; Takahiko, K; Moscovici, L; Campodonico, L; Oliveira-Ciabati, L; Laopaiboon, M; Danansuriya, M; Nakamura-Pereira, M; Costa, M L; Torloni, M R; Kramer, M R; Borges, P; Olkhanud, P B; Pérez-Cuevas, R; Agampodi, S B; Mittal, S; Serruya, S; Bataglia, V; Li, Z; Temmerman, M; Gülmezoglu, A M

    2016-02-01

    To generate a global reference for caesarean section (CS) rates at health facilities. Cross-sectional study. Health facilities from 43 countries. Thirty eight thousand three hundred and twenty-four women giving birth from 22 countries for model building and 10,045,875 women giving birth from 43 countries for model testing. We hypothesised that mathematical models could determine the relationship between clinical-obstetric characteristics and CS. These models generated probabilities of CS that could be compared with the observed CS rates. We devised a three-step approach to generate the global benchmark of CS rates at health facilities: creation of a multi-country reference population, building mathematical models, and testing these models. Area under the ROC curves, diagnostic odds ratio, expected CS rate, observed CS rate. According to the different versions of the model, areas under the ROC curves suggested a good discriminatory capacity of C-Model, with summary estimates ranging from 0.832 to 0.844. The C-Model was able to generate expected CS rates adjusted for the case-mix of the obstetric population. We have also prepared an e-calculator to facilitate use of C-Model (www.who.int/reproductivehealth/publications/maternal_perinatal_health/c-model/en/). This article describes the development of a global reference for CS rates. Based on maternal characteristics, this tool was able to generate an individualised expected CS rate for health facilities or groups of health facilities. With C-Model, obstetric teams, health system managers, health facilities, health insurance companies, and governments can produce a customised reference CS rate for assessing use (and overuse) of CS. The C-Model provides a customized benchmark for caesarean section rates in health facilities and systems. © 2015 World Health Organization; licensed by John Wiley & Sons Ltd on behalf of Royal College of Obstetricians and Gynaecologists.

  6. The Healthcare Administrator’s Desk Reference: A Managed Care and Health Care Contracting Dictionary for the Military Health System

    DTIC Science & Technology

    1998-07-01

    Intermediate Care Facility ICN Internal Control Number ICU Intensive Care Unit Desk Reference 59 ID Identification IDC Independent Duty Corpsman IDFN... Intermediate Care Facility -- A less expensive healthcare setting for patients who are not in need of acute or skilled nursing care but yet need more care

  7. Rolling-Bearing Service Life Based on Probable Cause for Removal: A Tutorial

    NASA Technical Reports Server (NTRS)

    Zaretsky, Erwin V.; Branzai, Emanuel V.

    2017-01-01

    In 1947 and 1952, Gustaf Lundberg and Arvid Palmgren developed what is now referred to as the Lundberg-Palmgren Model for Rolling Bearing Life Prediction based on classical rolling-element fatigue. Today, bearing fatigue probably accounts for less than 5 percent of bearings removed from service for cause. A bearing service life prediction methodology and tutorial indexed to eight probable causes for bearing removal, including fatigue, are presented, which incorporate strict series reliability; Weibull statistical analysis; available published field data from the Naval Air Rework Facility; and 224,000 rolling-element bearings removed for rework from commercial aircraft engines.

  8. Arts Education Facilities Planner for Grades K-8.

    ERIC Educational Resources Information Center

    North Carolina State Dept. of Public Instruction, Raleigh.

    This reference document for public school facility designers addresses arts education programs and the facilities that support them. Some sections focus on concepts and features common to most or all arts education subject areas, such as sound management, acoustical design, teacher workstations, and performance facilities. Other sections describe…

  9. 47 CFR 27.804 - Field strength limits at WMTS facility.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Field strength limits at WMTS facility. 27.804... MISCELLANEOUS WIRELESS COMMUNICATIONS SERVICES 1.4 GHz Band § 27.804 Field strength limits at WMTS facility. For any operation in the 1392-1395 MHz band, the predicted or measured field strength—into the WMTS band...

  10. 47 CFR 27.804 - Field strength limits at WMTS facility.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 2 2011-10-01 2011-10-01 false Field strength limits at WMTS facility. 27.804... MISCELLANEOUS WIRELESS COMMUNICATIONS SERVICES 1.4 GHz Band § 27.804 Field strength limits at WMTS facility. For any operation in the 1392-1395 MHz band, the predicted or measured field strength—into the WMTS band...

  11. Characterization of extended range Bonner Sphere Spectrometers in the CERF high-energy broad neutron field at CERN

    NASA Astrophysics Data System (ADS)

    Agosteo, S.; Bedogni, R.; Caresana, M.; Charitonidis, N.; Chiti, M.; Esposito, A.; Ferrarini, M.; Severino, C.; Silari, M.

    2012-12-01

    The accurate determination of the ambient dose equivalent in the mixed neutron-photon fields encountered around high-energy particle accelerators still represents a challenging task. The main complexity arises from the extreme variability of the neutron energy, which spans over 10 orders of magnitude or more. Operational survey instruments, which response function attempts to mimic the fluence-to-ambient dose equivalent conversion coefficient up to GeV neutrons, are available on the market, but their response is not fully reliable over the entire energy range. Extended range rem counters (ERRC) do not require the exact knowledge of the energy distribution of the neutron field and the calibration can be done with a source spectrum. If the actual neutron field has an energy distribution different from the calibration spectrum, the measurement is affected by an added uncertainty related to the partial overlap of the fluence-to-ambient dose equivalent conversion curve and the response function. For this reason their operational use should always be preceded by an "in-field" calibration, i.e. a calibration made against a reference instrument exposed in the same field where the survey-meter will be employed. In practice the extended-range Bonner Sphere Spectrometer (ERBSS) is the only device which can serve as reference instrument in these fields, because of its wide energy range and the possibility to assess the neutron fluence and the ambient dose equivalent (H*(10)) values with the appropriate accuracy. Nevertheless, the experience gained by a number of experimental groups suggests that mandatory conditions for obtaining accurate results in workplaces are: (1) the use of a well-established response matrix, thus implying validation campaigns in reference monochromatic neutrons fields, (2) the expert and critical use of suitable unfolding codes, and (3) the performance test of the whole system (experimental set-up, elaboration and unfolding procedures) in a well controlled workplace field. The CERF (CERN-EU high-energy reference field) facility is a unique example of such a field, where a number of experimental campaigns and Monte Carlo simulations have been performed over the past years. With the aim of performing this kind of workplace performance test, four different ERBSS with different degrees of validation, operated by three groups (CERN, INFN-LNF and Politecnico of Milano), were exposed in two fixed positions at CERF. Using different unfolding codes (MAXED, GRAVEL, FRUIT and FRUIT SGM), the experimental data were analyzed to provide the neutron spectra and the related dosimetric quantities. The results allow assessing the overall performance of each ERBSS and of the unfolding codes, as well as comparing the performance of three ERRCs when used in a neutron field with energy distribution different from the calibration spectrum.

  12. Evaluation of Nuclear Facility Decommissioning Projects program: a reference research reactor. Project summary report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baumann, B.L.; Miller, R.L.

    1983-10-01

    This document presents, in summary form, generic conceptual information relevant to the decommissioning of a reference research reactor (RRR). All of the data presented were extracted from NUREG/CR-1756 and arranged in a form that will provide a basis for future comparison studies for the Evaluation of Nuclear Facility Decommissioning Projects (ENFDP) program.

  13. Stable isotope sales: Mound Facility customer and shipment summaries, FY 1981

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ruwe, Jr, A H

    1982-10-01

    A listing is given of Mound Facility's sales of stable isotopes of noble gases, carbon, oxygen, nitrogen, chlorine, and sulfur for Fiscal Year 1981. Purchasers are listed alphabetically and are divided into domestic and foreign groups. A cross-reference index by location is included for domestic customers. Cross-reference listings by isotope purchased are included for all customers.

  14. 47 CFR 73.208 - Reference points and distance computations.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... SERVICES RADIO BROADCAST SERVICES FM Broadcast Stations § 73.208 Reference points and distance computations... filed no later than: (i) The last day of a filing window if the application is for a new FM facility or...(d) and 73.3573(e) if the application is for a new FM facility or a major change in the reserved band...

  15. 47 CFR 73.208 - Reference points and distance computations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... SERVICES RADIO BROADCAST SERVICES FM Broadcast Stations § 73.208 Reference points and distance computations... filed no later than: (i) The last day of a filing window if the application is for a new FM facility or...(d) and 73.3573(e) if the application is for a new FM facility or a major change in the reserved band...

  16. GCR Simulator Development Status at the NASA Space Radiation Laboratory

    NASA Technical Reports Server (NTRS)

    Slaba, T. C.; Norbury, J. W.; Blattnig, S. R.

    2015-01-01

    There are large uncertainties connected to the biological response for exposure to galactic cosmic rays (GCR) on long duration deep space missions. In order to reduce the uncertainties and gain understanding about the basic mechanisms through which space radiation initiates cancer and other endpoints, radiobiology experiments are performed with mono-energetic ions beams. Some of the accelerator facilities supporting such experiments have matured to a point where simulating the broad range of particles and energies characteristic of the GCR environment in a single experiment is feasible from a technology, usage, and cost perspective. In this work, several aspects of simulating the GCR environment at the NASA Space Radiation Laboratory (NSRL) are discussed. First, comparisons are made between direct simulation of the external, free space GCR field, and simulation of the induced tissue field behind shielding. It is found that upper energy constraints at NSRL limit the ability to simulate the external, free space field directly (i.e. shielding placed in the beam line in front of a biological target and exposed to a free space spectrum). Second, a reference environment for the GCR simulator and suitable for deep space missions is identified and described in terms of fluence and integrated dosimetric quantities. Analysis results are given to justify the use of a single reference field over a range of shielding conditions and solar activities. Third, an approach for simulating the reference field at NSRL is presented. The approach directly considers the hydrogen and helium energy spectra, and the heavier ions are collectively represented by considering the linear energy transfer (LET) spectrum. While many more aspects of the experimental setup need to be considered before final implementation of the GCR simulator, this preliminary study provides useful information that should aid the final design. Possible drawbacks of the proposed methodology are discussed and weighed against alternative simulation strategies.

  17. Information on the Advanced Plant Experiment (APEX) Test Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, Curtis Lee

    The purpose of this report provides information related to the design of the Oregon State University Advanced Plant Experiment (APEX) test facility. Information provided in this report have been pulled from the following information sources: Reference 1: R. Nourgaliev and et.al, "Summary Report on NGSAC (Next-Generation Safety Analysis Code) Development and Testing," Idaho National Laboratory, 2011. Note that this is report has not been released as an external report. Reference 2: O. Stevens, Characterization of the Advanced Plant Experiment (APEX) Passive Residual Heat Removal System Heat Exchanger, Master Thesis, June 1996. Reference 3: J. Reyes, Jr., Q. Wu, and J.more » King, Jr., Scaling Assessment for the Design of the OSU APEX-1000 Test Facility, OSU-APEX-03001 (Rev. 0), May 2003. Reference 4: J. Reyes et al, Final Report of the NRC AP600 Research Conducted at Oregon State University, NUREG/CR-6641, July 1999. Reference 5: K. Welter et al, APEX-1000 Confirmatory Testing to Support AP1000 Design Certification (non-proprietary), NUREG-1826, August 2005.« less

  18. Sound field diffusivity in NASA Langley Research Center hardwalled acoustic facilities

    NASA Technical Reports Server (NTRS)

    Mcgary, M. C.

    1982-01-01

    Cross correlation measurements were performed to determine the quality of the sound fields in the ANRL reverberation room and the ANRL transmission loss facility. The results indicate the level of sound field diffuseness which may be attained in these hardwalled acoustic facilities.

  19. Arts Education Facilities Planner for Grades 9-12.

    ERIC Educational Resources Information Center

    North Carolina State Dept. of Public Instruction, Raleigh. Div. of School Support.

    This document suggests facilities necessary to conduct instruction in arts programs in grades 9-12 and conveys essential features that should be present. As a reference document for school facilities designers, it describes arts education programs and the facilities that support them, with some sections focusing on the concepts and features common…

  20. Large Indoor Sports and Recreation Facilities.

    ERIC Educational Resources Information Center

    Seidler, Todd

    This paper presents an overview and analysis of field houses, stadiums, arenas, and campus recreation centers. All are large indoor sports or recreation facilities. In general, stadiums and arenas are spectator facilities while field houses and campus recreation centers are primarily designed for activity. A college field house is a structure that…

  1. 36th International Conference on High Energy Physics

    NASA Astrophysics Data System (ADS)

    The Australian particle physics community was honoured to host the 36th ICHEP conference in 2012 in Melbourne. This conference has long been the reference event for our international community. The announcement of the discovery of the Higgs boson at the LHC was a major highlight, with huge international press coverage. ICHEP2012 was described by CERN Director-General, Professor Rolf Heuer, as a landmark conference for our field. In additional to the Higgs announcement, important results from neutrino physics, from flavour physics, and from physics beyond the standard model also provided great interest. There were also updates on key accelerator developments such as the new B-factories, plans for the LHC upgrade, neutrino facilities and associated detector developments. ICHEP2012 exceeded the promise expected of the key conference for our field, and really did provide a reference point for the future. Many thanks to the contribution reviewers: Andy Bakich, Csaba Balazs, Nicole Bell, Catherine Buchanan, Will Crump, Cameron Cuthbert, Ben Farmer, Sudhir Gupta, Elliot Hutchison, Paul Jackson, Geng-Yuan Jeng, Archil Kobakhidze, Doyoun Kim, Tong Li, Antonio Limosani (Head Editor), Kristian McDonald, Nikhul Patel, Aldo Saavedra, Mark Scarcella, Geoff Taylor, Ian Watson, Graham White, Tony Williams and Bruce Yabsley.

  2. Quality assurance in nuclear medicine facilities; availability of final recommendations--FDA. Notice.

    PubMed

    1985-05-13

    The Food and Drug Administration (FDA) is announcing the availability of final recommendations prepared by its Center for Devices and Radiological Health (CDRH) on quality assurance programs in nuclear medicine facilities. The final recommendations include the agency's rationale for the recommendations as well as references that can be used as well as references that can be used as guides in conducting quality control monitoring. These final recommendations are available as a technical report in CDRH's radiation recommendations series. They are intended to encourage and promote the development of voluntary quality assurance programs in nuclear medicine facilities.

  3. Directional Attenuation of Jet Noise With Eccentric Coannular Nozzle Investigated

    NASA Technical Reports Server (NTRS)

    Zaman, Khairul B.

    2005-01-01

    Jet noise and flow field were measured to follow up on observations made by Professor D. Papamoschou of the University of California at Irvine (NASA Grant NAG3-2345). When a dual-stream coannular nozzle was arranged non-concentrically, noise was attenuated significantly on the side where the annulus was thicker. A similar observation was also made in reference 2. The practical significance is obvious. If the bypass flow of a jet exhaust in flight could be diverted to form a thicker layer underneath, then less noise would be heard by an observer on the ground. In view of the current emphasis on jet noise abatement, researchers felt that the effect deserved further attention. This prompted an experiment to confirm the phenomenon in a larger facility and to obtain flow-field data to advance understanding of the mechanism.

  4. Structural Acoustic Prediction and Interior Noise Control Technology

    NASA Technical Reports Server (NTRS)

    Mathur, G. P.; Chin, C. L.; Simpson, M. A.; Lee, J. T.; Palumbo, Daniel L. (Technical Monitor)

    2001-01-01

    This report documents the results of Task 14, "Structural Acoustic Prediction and Interior Noise Control Technology". The task was to evaluate the performance of tuned foam elements (termed Smart Foam) both analytically and experimentally. Results taken from a three-dimensional finite element model of an active, tuned foam element are presented. Measurements of sound absorption and sound transmission loss were taken using the model. These results agree well with published data. Experimental performance data were taken in Boeing's Interior Noise Test Facility where 12 smart foam elements were applied to a 757 sidewall. Several configurations were tested. Noise reductions of 5-10 dB were achieved over the 200-800 Hz bandwidth of the controller. Accelerometers mounted on the panel provided a good reference for the controller. Configurations with far-field error microphones outperformed near-field cases.

  5. 10 CFR 75.10 - Facility information.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... features of the facility relating to material accounting, containment, and surveillance; (4) A description of the existing and proposed procedures at the facility for nuclear material accounting and control, with special reference to material balance areas established by the licensee, measurement of flow, and...

  6. A Global Survey of Deep Underground Facilities; Examples of Geotechnical and Engineering Capabilities, Achievements, Challenges (Mines, Shafts, Tunnels, Boreholes, Sites and Underground Facilities for Nuclear Waste and Physics R&D): A Guide to Interactive Global Map Layers, Table Database, References and Notes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tynan, Mark C.; Russell, Glenn P.; Perry, Frank V.

    These associated tables, references, notes, and report present a synthesis of some notable geotechnical and engineering information used to create four interactive layer maps for selected: 1) deep mines and shafts; 2) existing, considered or planned radioactive waste management deep underground studies or disposal facilities 3) deep large diameter boreholes, and 4) physics underground laboratories and facilities from around the world. These data are intended to facilitate user access to basic information and references regarding “deep underground” facilities, history, activities, and plans. In general, the interactive maps and database provide each facility’s approximate site location, geology, and engineered features (e.g.:more » access, geometry, depth, diameter, year of operations, groundwater, lithology, host unit name and age, basin; operator, management organization, geographic data, nearby cultural features, other). Although the survey is not comprehensive, it is representative of many of the significant existing and historical underground facilities discussed in the literature addressing radioactive waste management and deep mined geologic disposal safety systems. The global survey is intended to support and to inform: 1) interested parties and decision makers; 2) radioactive waste disposal and siting option evaluations, and 3) safety case development applicable to any mined geologic disposal facility as a demonstration of historical and current engineering and geotechnical capabilities available for use in deep underground facility siting, planning, construction, operations and monitoring.« less

  7. Occupational exposure of healthcare and research staff to static magnetic stray fields from 1.5–7 Tesla MRI scanners is associated with reporting of transient symptoms

    PubMed Central

    Schaap, Kristel; Christopher-de Vries, Yvette; Mason, Catherine K; de Vocht, Frank; Portengen, Lützen; Kromhout, Hans

    2014-01-01

    Objectives Limited data is available about incidence of acute transient symptoms associated with occupational exposure to static magnetic stray fields from MRI scanners. We aimed to assess the incidence of these symptoms among healthcare and research staff working with MRI scanners, and their association with static magnetic field exposure. Methods We performed an observational study among 361 employees of 14 clinical and research MRI facilities in The Netherlands. Each participant completed a diary during one or more work shifts inside and/or outside the MRI facility, reporting work activities and symptoms (from a list of potentially MRI-related symptoms, complemented with unrelated symptoms) experienced during a working day. We analysed 633 diaries. Exposure categories were defined by strength and type of MRI scanner, using non-MRI shifts as the reference category for statistical analysis. Non-MRI shifts originated from MRI staff who also participated on MRI days, as well as CT radiographers who never worked with MRI. Results Varying per exposure category, symptoms were reported during 16–39% of the MRI work shifts. We observed a positive association between scanner strength and reported symptoms among healthcare and research staff working with closed-bore MRI scanners of 1.5 Tesla (T) and higher (1.5 T OR=1.88; 3.0 T OR=2.14; 7.0 T OR=4.17). This finding was mainly driven by reporting of vertigo and metallic taste. Conclusions The results suggest an exposure-response association between exposure to strong static magnetic fields (and associated motion-induced time-varying magnetic fields) and reporting of transient symptoms on the same day of exposure. Trial registration number 11-032/C PMID:24714654

  8. Measurement and simulation of lineal energy distribution at the CERN high energy facility with a tissue equivalent proportional counter.

    PubMed

    Rollet, S; Autischer, M; Beck, P; Latocha, M

    2007-01-01

    The response of a tissue equivalent proportional counter (TEPC) in a mixed radiation field with a neutron energy distribution similar to the radiation field at commercial flight altitudes has been studied. The measurements have been done at the CERN-EU High-Energy Reference Field (CERF) facility where a well-characterised radiation field is available for intercomparison. The TEPC instrument used by the ARC Seibersdorf Research is filled with pure propane gas at low pressure and can be used to determine the lineal energy distribution of the energy deposition in a mass of gas equivalent to a 2 microm diameter volume of unit density tissue, of similar size to the nuclei of biological cells. The linearity of the detector response was checked both in term of dose and dose rate. The effect of dead-time has been corrected. The influence of the detector exposure location and orientation in the radiation field on the dose distribution was also studied as a function of the total dose. The microdosimetric distribution of the absorbed dose as a function of the lineal energy has been obtained and compared with the same distribution simulated with the FLUKA Monte Carlo transport code. The dose equivalent was calculated by folding this distribution with the quality factor as a function of linear energy transfer. The comparison between the measured and simulated distributions show that they are in good agreement. As a result of this study the detector is well characterised, thanks also to the numerical simulations the instrument response is well understood, and it's currently being used onboard the aircrafts to evaluate the dose to aircraft crew caused by cosmic radiation.

  9. The Role of Health Extension Workers in Linking Pregnant Women With Health Facilities for Delivery in Rural and Pastoralist Areas of Ethiopia.

    PubMed

    Jackson, Ruth; Hailemariam, Assefa

    2016-09-01

    Women's preference to give birth at home is deeply embedded in Ethiopian culture. Many women only go to health facilities if they have complications during birth. Health Extension Workers (HEWs) have been deployed to improve the utilization of maternal health services by bridging the gap between communities and health facilities. This study examined the barriers and facilitators for HEWs as they refer women to mid-level health facilities for birth. A qualitative study was conducted in three regions: Afar Region, Southern Nations Nationalities and People's Region and Tigray Region between March to December 2014. Interviews and focus group discussions were conducted with 45 HEWs, 14 women extension workers (employed by Afar Pastoralist Development Association, Afar Region) and 11 other health workers from health centers, hospitals or health offices. Data analysis was done based on collating the data and identifying key themes. Barriers to health facilities included distance, lack of transportation, sociocultural factors and disrespectful care. Facilitators for facility-based deliveries included liaising with Health Development Army (HDA) leaders to refer women before their expected due date or if labour starts at home; the introduction of ambulance services; and, provision of health services that are culturally more acceptable for women. HEWs can effectively refer more women to give birth in health facilities when the HDA is well established, when health staff provide respectful care, and when ambulance is available at any time.

  10. A 2D ion chamber array audit of wedged and asymmetric fields in an inhomogeneous lung phantom

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lye, Jessica; Dunn, Leon, E-mail: leon.dunn@arpansa.gov.au; Alves, Andrew

    Purpose: The Australian Clinical Dosimetry Service (ACDS) has implemented a new method of a nonreference condition Level II type dosimetric audit of radiotherapy services to increase measurement accuracy and patient safety within Australia. The aim of this work is to describe the methodology, tolerances, and outcomes from the new audit. Methods: The ACDS Level II audit measures the dose delivered in 2D planes using an ionization chamber based array positioned at multiple depths. Measurements are made in rectilinear homogeneous and inhomogeneous phantoms composed of slabs of solid water and lung. Computer generated computed tomography data sets of the rectilinear phantomsmore » are supplied to the facility prior to audit for planning of a range of cases including reference fields, asymmetric fields, and wedged fields. The audit assesses 3D planning with 6 MV photons with a static (zero degree) gantry. Scoring is performed using local dose differences between the planned and measured dose within 80% of the field width. The overall audit result is determined by the maximum dose difference over all scoring points, cases, and planes. Pass (Optimal Level) is defined as maximum dose difference ≤3.3%, Pass (Action Level) is ≤5.0%, and Fail (Out of Tolerance) is >5.0%. Results: At close of 2013, the ACDS had performed 24 Level II audits. 63% of the audits passed, 33% failed, and the remaining audit was not assessable. Of the 15 audits that passed, 3 were at Pass (Action Level). The high fail rate is largely due to a systemic issue with modeling asymmetric 60° wedges which caused a delivered overdose of 5%–8%. Conclusions: The ACDS has implemented a nonreference condition Level II type audit, based on ion chamber 2D array measurements in an inhomogeneous slab phantom. The powerful diagnostic ability of this audit has allowed the ACDS to rigorously test the treatment planning systems implemented in Australian radiotherapy facilities. Recommendations from audits have led to facilities modifying clinical practice and changing planning protocols.« less

  11. Indirect Lightning Safety Assessment Methodology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ong, M M; Perkins, M P; Brown, C G

    2009-04-24

    Lightning is a safety hazard for high-explosives (HE) and their detonators. In the However, the current flowing from the strike point through the rebar of the building The methodology for estimating the risk from indirect lighting effects will be presented. It has two parts: a method to determine the likelihood of a detonation given a lightning strike, and an approach for estimating the likelihood of a strike. The results of these two parts produce an overall probability of a detonation. The probability calculations are complex for five reasons: (1) lightning strikes are stochastic and relatively rare, (2) the quality ofmore » the Faraday cage varies from one facility to the next, (3) RF coupling is inherently a complex subject, (4) performance data for abnormally stressed detonators is scarce, and (5) the arc plasma physics is not well understood. Therefore, a rigorous mathematical analysis would be too complex. Instead, our methodology takes a more practical approach combining rigorous mathematical calculations where possible with empirical data when necessary. Where there is uncertainty, we compensate with conservative approximations. The goal is to determine a conservative estimate of the odds of a detonation. In Section 2, the methodology will be explained. This report will discuss topics at a high-level. The reasons for selecting an approach will be justified. For those interested in technical details, references will be provided. In Section 3, a simple hypothetical example will be given to reinforce the concepts. While the methodology will touch on all the items shown in Figure 1, the focus of this report is the indirect effect, i.e., determining the odds of a detonation from given EM fields. Professor Martin Uman from the University of Florida has been characterizing and defining extreme lightning strikes. Using Professor Uman's research, Dr. Kimball Merewether at Sandia National Laboratory in Albuquerque calculated the EM fields inside a Faraday-cage type facility, when the facility is struck by lightning. In the following examples we will use Dr. Merewether's calculations from a poor quality Faraday cage as the input for the RF coupling analysis. coupling of radio frequency (RF) energy to explosive components is an indirect effect of currents [1]. If HE is adequately separated from the walls of the facility that is struck by disassembled have been turned into Faraday-cage structures to protect against lightning is initiation of the HE. last couple of decades, DOE facilities where HE is manufactured, assembled, stored or lightning. The most sensitive component is typically a detonator, and the safety concern lightning, electrons discharged from the clouds should not reach the HE components. radio receiver, the metal cable of a detonator can extract energy from the EM fields. This to the earth will create electromagnetic (EM) fields in the facility. Like an antenna in a« less

  12. The AuScope geodetic VLBI array

    NASA Astrophysics Data System (ADS)

    Lovell, J. E. J.; McCallum, J. N.; Reid, P. B.; McCulloch, P. M.; Baynes, B. E.; Dickey, J. M.; Shabala, S. S.; Watson, C. S.; Titov, O.; Ruddick, R.; Twilley, R.; Reynolds, C.; Tingay, S. J.; Shield, P.; Adada, R.; Ellingsen, S. P.; Morgan, J. S.; Bignall, H. E.

    2013-06-01

    The AuScope geodetic Very Long Baseline Interferometry array consists of three new 12-m radio telescopes and a correlation facility in Australia. The telescopes at Hobart (Tasmania), Katherine (Northern Territory) and Yarragadee (Western Australia) are co-located with other space geodetic techniques including Global Navigation Satellite Systems (GNSS) and gravity infrastructure, and in the case of Yarragadee, satellite laser ranging (SLR) and Doppler Orbitography and Radiopositioning Integrated by Satellite (DORIS) facilities. The correlation facility is based in Perth (Western Australia). This new facility will make significant contributions to improving the densification of the International Celestial Reference Frame in the Southern Hemisphere, and subsequently enhance the International Terrestrial Reference Frame through the ability to detect and mitigate systematic error. This, combined with the simultaneous densification of the GNSS network across Australia, will enable the improved measurement of intraplate deformation across the Australian tectonic plate. In this paper, we present a description of this new infrastructure and present some initial results, including telescope performance measurements and positions of the telescopes in the International Terrestrial Reference Frame. We show that this array is already capable of achieving centimetre precision over typical long-baselines and that network and reference source systematic effects must be further improved to reach the ambitious goals of VLBI2010.

  13. Nuclear facility decommissioning and site remedial actions: a selected bibliography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Owen, P.T.; Knox, N.P.; Fielden, J.M.

    This bibliography contains 693 references with abstracts on the subject of nuclear facility decommissioning, uranium mill tailings management, and site remedial actions. Foreign, as well as domestic, literature of all types - technical reports, progress reports, journal articles, conference papers, symposium proceedings, theses, books, patents, legislation, and research project descriptions - has been included in this publication. The bibliography contains scientific (basic research as well as applied technology), economic, regulatory, and legal literature pertinent to the US Department of Energy's Remedial Action Program. Major chapters are Surplus Facilities Management Program, Nuclear Facilities Decommissioning, Formerly Utilized Sites Remedial Action Program, Uraniummore » Mill Tailings Remedial Action Program, Grand Junction Remedial Action Program, and Uranium Mill Tailings Management. Chapter sections for chapters 1 and 2 include: Design, Planning, and Regulations; Site Surveys; Decontamination Studies; Dismantlement and Demolition; Land Decontamination and Reclamation; Waste Disposal; and General Studies. The references within each chapter are arranged alphabetically by leading author. References having no individual author are arranged by corporate author or by title. Indexes are provided for (1) author; (2) corporate affiliation; (3) title; (4) publication description; (5) geographic location; and (6) keywords. An appendix of 202 bibliographic references without abstracts or indexes has been included in this bibliography. This appendix represents literature identified but not abstracted due to time constraints.« less

  14. Construction of 144, 565 keV and 5.0 MeV monoenergetic neutron calibration fields at JAERI.

    PubMed

    Tanimura, Y; Yoshizawa, M; Saegusa, J; Fujii, K; Shimizu, S; Yoshida, M; Shibata, Y; Uritani, A; Kudo, K

    2004-01-01

    Monoenergetic neutron calibration fields of 144, 565 keV and 5.0 MeV have been developed at the Facility of Radiation Standards of JAERI using a 4 MV Pelletron accelerator. The 7Li(p,n)7Be and 2H(d,n)3He reactions are employed for neutron production. The neutron energy was measured by the time-of-flight method with a liquid scintillation detector and calculated with the MCNP-ANT code. A long counter is employed as a neutron monitor because of the flat response. The monitor is set up where the influence of inscattered neutrons from devices and their supporting materials at a calibration point is as small as possible. The calibration coefficients from the monitor counts to the neutron fluence at a calibration point were obtained from the reference fluence measured with the transfer instrument of the primary standard laboratory (AIST), a 24.13 cm phi Bonner sphere counter. The traceability of the fields to AIST was established through the calibration.

  15. The change in critical technologies for computational physics

    NASA Technical Reports Server (NTRS)

    Watson, Val

    1990-01-01

    It is noted that the types of technology required for computational physics are changing as the field matures. Emphasis has shifted from computer technology to algorithm technology and, finally, to visual analysis technology as areas of critical research for this field. High-performance graphical workstations tied to a supercommunicator with high-speed communications along with the development of especially tailored visualization software has enabled analysis of highly complex fluid-dynamics simulations. Particular reference is made here to the development of visual analysis tools at NASA's Numerical Aerodynamics Simulation Facility. The next technology which this field requires is one that would eliminate visual clutter by extracting key features of simulations of physics and technology in order to create displays that clearly portray these key features. Research in the tuning of visual displays to human cognitive abilities is proposed. The immediate transfer of technology to all levels of computers, specifically the inclusion of visualization primitives in basic software developments for all work stations and PCs, is recommended.

  16. [The Nature and Issues of Drug Addiction Treatment under Constraint].

    PubMed

    Quirion, Bastien

    This article is exploring different forms of constraint that are exerted in the field of drug addiction treatment. The objective of this article is to establish benchmarks and to stimulate reflection about the ethical and clinical implications of those constraints in the field of drug addiction treatment. This article is presenting a critical review of different forms of constraint that can be exerted in Canada in regard to the treatment of drug addiction. In the first section of the article, a definition of therapeutic intervention is proposed, that includes the dimension of power, which justifies the importance of considering the coercive aspects of treatment. The second section, which represents the core section of the paper, is devoted to the presentation of different levels of constraint that can be distinguished in regard to drug addicts who are under treatment. Three levels of constraint are exposed: judicial constraint, institutional constraint and relational constraint. The coercive aspect of treatment can then be recognized as a combination of all tree levels of constraint. Judicial constraint refers to any form of constraint in which the court or the judge is imposing or recommending treatment. This particular level of constraint can take different forms, such as therapeutic remands, conditions of a probation order, conditions of a conditional sentence of imprisonment, and coercive treatment such as the ones provided through drug courts. Institutional constraint refers to any form of constraint exerted within any institutional setting, such as correctional facilities and programs offered in community. Correctional facilities being limited by their own specific mission, it might have a major impact on the way the objectives of treatment are defined. Those limitations can then be considered as a form of constraint, in which drug users don't have much space to express their personal needs. Finally, relational constraint refers to any form of constraint in which the drug addict might be coerced to treatment under the pressure of people from the immediate environment, such as members of family, friends or employers. Even if this form of constraint is not as obvious as the ones exerted by court and correctional facilities, it has to be considered by practitioners who are evaluating the motivation of drug addicts under treatment. Considering the diversity of constraints that are exerted on drug addicts who are under treatment, it appears that we should be always aware of the ethical and clinical challenges facing practitioners every day. The recognition of those constraints can also help to understand how important it is to consider the institutional and social context in which treatment is being provided.

  17. Calculation of conversion coefficients using Chinese adult reference phantoms for air submersion and ground contamination.

    PubMed

    Lu, Wei; Qiu, Rui; Wu, Zhen; Li, Chunyan; Yang, Bo; Liu, Huan; Ren, Li; Li, Junli

    2017-03-21

    The effective and organ equivalent dose coefficients have been widely used to provide assessment of doses received by adult members of the public and by workers exposed to environmental radiation from nuclear facilities under normal or accidental situations. Advancements in phantom types, weighting factors, decay data, etc, have led to the publication of newer results in this regard. This paper presents a new set of conversion coefficients for air submersion and ground contamination (with the use of Geant4) for photons from 15 keV to 10 MeV using the Chinese and International Commission on Radiological Protection (ICRP) adult reference male and female phantoms. The radiation fields, except for energy spectrum at low energies, were validated by the data obtained from the Monte Carlo code YURI. The effective dose coefficients of monoenergetic photons, obtained for the ICRP adult reference phantoms, agree well with recently published data for air submersion and ground contamination with a plane source at a depth of 0.5 g cm -2 in soil, but an average difference of 36.5% is observed for ground surface contamination with the abovementioned radiation field. The average differences in organ equivalent dose coefficients between the Chinese and the ICRP adult reference phantoms are within 6% for most organs, but noticeable differences of up to 70% or even higher are found at photon energies below 30 keV under air submersion. The effective dose coefficients obtained with the Chinese adult reference phantoms are greater than those of the ICRP adult reference phantoms above 30 keV and 0.5 MeV for ground contamination and air submersion, respectively; the average differences from the Chinese adult reference phantoms are about 3.6% and 0.4% in the whole energy range with maximum differences of 31.8% and 27.6% at 15 keV for air submersion and ground contamination respectively. These differences are attributed to anatomical discrepancies in overlying tissue mass of an individual organ and the body mass between the Chinese and the ICRP adult reference phantoms. These monoenergetic photon conversion coefficients are subsequently used to evaluate radionuclides with decay data from ICRP publication 107.

  18. Calculation of conversion coefficients using Chinese adult reference phantoms for air submersion and ground contamination

    NASA Astrophysics Data System (ADS)

    Lu, Wei; Qiu, Rui; Wu, Zhen; Li, Chunyan; Yang, Bo; Liu, Huan; Ren, Li; Li, Junli

    2017-03-01

    The effective and organ equivalent dose coefficients have been widely used to provide assessment of doses received by adult members of the public and by workers exposed to environmental radiation from nuclear facilities under normal or accidental situations. Advancements in phantom types, weighting factors, decay data, etc, have led to the publication of newer results in this regard. This paper presents a new set of conversion coefficients for air submersion and ground contamination (with the use of Geant4) for photons from 15 keV to 10 MeV using the Chinese and International Commission on Radiological Protection (ICRP) adult reference male and female phantoms. The radiation fields, except for energy spectrum at low energies, were validated by the data obtained from the Monte Carlo code YURI. The effective dose coefficients of monoenergetic photons, obtained for the ICRP adult reference phantoms, agree well with recently published data for air submersion and ground contamination with a plane source at a depth of 0.5 g cm-2 in soil, but an average difference of 36.5% is observed for ground surface contamination with the abovementioned radiation field. The average differences in organ equivalent dose coefficients between the Chinese and the ICRP adult reference phantoms are within 6% for most organs, but noticeable differences of up to 70% or even higher are found at photon energies below 30 keV under air submersion. The effective dose coefficients obtained with the Chinese adult reference phantoms are greater than those of the ICRP adult reference phantoms above 30 keV and 0.5 MeV for ground contamination and air submersion, respectively; the average differences from the Chinese adult reference phantoms are about 3.6% and 0.4% in the whole energy range with maximum differences of 31.8% and 27.6% at 15 keV for air submersion and ground contamination respectively. These differences are attributed to anatomical discrepancies in overlying tissue mass of an individual organ and the body mass between the Chinese and the ICRP adult reference phantoms. These monoenergetic photon conversion coefficients are subsequently used to evaluate radionuclides with decay data from ICRP publication 107.

  19. Magnetostatic Surface Field Measurement Facility.

    DTIC Science & Technology

    1986-12-01

    Sphere 106 4 Page C .2 Acoustically Hard Prolate 10 8 HC.3 Perfectly Conducting Sphere 110 C .4 Some Implications 113 C .5 References 115 APPENDIX D 117 0.1...I/a2+ r2+z2 - 2ar cos a d -3, C 2 var 1 -K2 )K - / - E Jo 3ɚ- (2.37) and since J cos a da 0 0 we have . ... 1 2)K A = - -~i)Ej + 0 (k 3) . (2.38...assumed exp(jwt) time convention. C - We begin by analyzing one of our eight secondary distribution sub- systems, as shown in Fig. D .2. V -j- Z 0j B e Vx

  20. Nuclear reference materials to meet the changing needs of the global nuclear community

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martin, H.R.; Gradle, C.G.; Narayanan, U.I.

    New Brunswick Laboratory (NBL) serves as the U.S. Government`s certifying authority for nuclear reference materials and measurement calibration standards. In this role, NBL provides nuclear reference materials certified for chemical and/or isotopic compositions traceable to a nationally accepted, internationally compatible reference base. Emphasis is now changing as to the types of traceable nuclear reference materials needed as operations change within the Department of Energy complex and at nuclear facilities around the world. New challenges include: environmental and waste minimization issues, facilities and materials transitioning from processing to storage modes with corresponding changes in the types of measurements being performed, emphasismore » on requirements for characterization of waste materials, and difficulties in transporting nuclear materials and international factors, including IAEA influences. During these changing times, it is critical that traceable reference materials be provided for calibration or validation of the performance of measurement systems. This paper will describe actions taken and planned to meet the changing reference material needs of the global nuclear community.« less

  1. The accelerator facility of the Heidelberg Ion-Beam Therapy Centre (HIT)

    NASA Astrophysics Data System (ADS)

    Peters, Andreas

    The following sections are included: * Introduction * Beam parameters * General layout of the HIT facility * The accelerator chain in detail * Operational aspects of a particle therapy facility * 24/7 accelerator operation at 335 days per year * Safety and regulatory aspects * Status and perspectives * References

  2. 76 FR 64055 - Special Rules Governing Certain Information Obtained Under the Clean Air Act: Technical Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-17

    ... natural gas. 211112 Natural gas liquid extraction facilities. Petrochemical Production....... 32511... facilities. 211112 Natural gas liquid extraction facilities. Suppliers of Industrial 325120 Industrial gas... reference in EPA's procedures for handling data collected under the Mandatory Greenhouse Gas Reporting Rule...

  3. Collaboration of general practitioners and exercise providers in promotion of physical activity a written survey among general practitioners.

    PubMed

    Leemrijse, C J; de Bakker, D H; Ooms, L; Veenhof, C

    2015-08-06

    General practitioners have an ideal position to motivate inactive patients to increase their physical activity. Most patients are able to exercise in regular local facilities outside the health care setting. The purpose of this study was to get insight into general practitioners perceptions and current practices regarding referral of patients to local exercise facilities. Furthermore, collaboration with exercise providers in the community was investigated, and motivators and barriers for referral. A written questionnaire sent to a representative random sample of 800 Dutch general practitioners. Descriptive statistics and Chi(2) tests were used. All responding general practitioners (340) recommend their patients to take more exercise when necessary and 87 % say to refer patients sometimes. Limited motivation of the patient (44 %) and reduced health status (34 %) are the most mentioned barriers for advising patients to increase physical activity. When referred, most patients are send to a physical therapist (69 %) but also local exercise facilities were mentioned (54 %). The most important barrier for referring patients to local exercise activities are patients limited financial possibilities (46 %). Restricted knowledge of local exercise- or sport facilities was an additional barrier (19 %). There is little structural collaboration between general practitioners and exercise providers, but when collaboration exists general practitioners refer more often. Positive experiences of patients (67 %), affordable offers (59 %) and information of local exercise facilities (46 %) are seen as important promoting factors for referral. Although 32 % of the general practitioners think that good collaboration would be stimulating, regular meetings with sports and exercise providers were considered the least important for increasing referral (3 %). Dutch physicians have a positive attitude towards stimulating physical activity but referral to local exercise facilities is low. Referral is partly hindered by restricted knowledge of local exercise facilities. Although general practitioners think that collaboration is important for physical activity promotion, it should not cost them much extra time. A coordinator with knowledge of the local situation can facilitate contacts between GP practices and sports providers.

  4. Psychiatric diagnoses in patients with burning mouth syndrome and atypical odontalgia referred from psychiatric to dental facilities

    PubMed Central

    Takenoshita, Miho; Sato, Tomoko; Kato, Yuichi; Katagiri, Ayano; Yoshikawa, Tatsuya; Sato, Yusuke; Matsushima, Eisuke; Sasaki, Yoshiyuki; Toyofuku, Akira

    2010-01-01

    Background Burning mouth syndrome (BMS) and atypical odontalgia (AO) are two conditions involving chronic oral pain in the absence of any organic cause. Psychiatrically they can both be considered as “somatoform disorder”. From the dental point of view, however, the two disorders are quite distinct. BMS is a burning or stinging sensation in the mouth in association with a normal mucosa whereas AO is most frequently associated with a continuous pain in the teeth or in a tooth socket after extraction in the absence of any identifiable cause. Because of the absence of organic causes, BMS and AO are often regarded as psychogenic conditions, although the relationship between oral pain and psychologic factors is still unclear. Some studies have analyzed the psychiatric diagnoses of patients with chronic oral pain who have been referred from dental facilities to psychiatric facilities. No study to date has investigated patients referred from psychiatric facilities to dental facilities. Objective To analyze the psychiatric diagnoses of chronic oral pain patients, diagnosed with BMS and AO, and referred from psychiatric facilities to dental facilities. Study design Psychiatric diagnoses and disease conditions of BMS or AO were investigated in 162 patients by reviewing patients’ medical records and referral forms. Psychiatric diagnoses were categorized according to the International Statistical Classification of Disease and Related Health Problems, Tenth Revision. Results The proportion of F4 classification (neurotic, stress-related, and somatoform disorders) in AO patients was significantly higher than in BMS patients. BMS patients were more frequently given a F3 classification (mood/affective disorders). However, 50.8% of BMS patients and 33.3% of AO patients had no specific psychiatric diagnoses. Conclusion Although BMS and AO are both chronic pain disorders occurring in the absence of any organic cause, the psychiatric diagnoses of patients with BMS and AO differ substantially. PMID:21127687

  5. 18 CFR 281.203 - Definitions and cross references.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... power generation. (10) Hospital means a facility, the primary function of which is delivering medical... clinics or doctors' offices are not included in this definition. (11) School means a facility, the primary function of which is to deliver instruction to regularly enrolled students in attendance at such facility...

  6. 18 CFR 281.203 - Definitions and cross references.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... power generation. (10) Hospital means a facility, the primary function of which is delivering medical... clinics or doctors' offices are not included in this definition. (11) School means a facility, the primary function of which is to deliver instruction to regularly enrolled students in attendance at such facility...

  7. 18 CFR 281.203 - Definitions and cross references.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... power generation. (10) Hospital means a facility, the primary function of which is delivering medical... clinics or doctors' offices are not included in this definition. (11) School means a facility, the primary function of which is to deliver instruction to regularly enrolled students in attendance at such facility...

  8. 18 CFR 281.203 - Definitions and cross references.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... power generation. (10) Hospital means a facility, the primary function of which is delivering medical... clinics or doctors' offices are not included in this definition. (11) School means a facility, the primary function of which is to deliver instruction to regularly enrolled students in attendance at such facility...

  9. 18 CFR 281.203 - Definitions and cross references.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... power generation. (10) Hospital means a facility, the primary function of which is delivering medical... clinics or doctors' offices are not included in this definition. (11) School means a facility, the primary function of which is to deliver instruction to regularly enrolled students in attendance at such facility...

  10. School Building Designs: Principles and Challenges of the 21st Century.

    ERIC Educational Resources Information Center

    Chan, T. C.

    2002-01-01

    Reviews school-facility challenges and design principles described in 2000 U.S. Department of Education report on school planning and design. Describes additional school-facility design challenges and planning principles. Describes five critical facility-planning issues for the 21st Century. (Contains 14 references.) (PKP)

  11. Nuclear facility decommissioning and site remedial actions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Knox, N.P.; Webb, J.R.; Ferguson, S.D.

    1990-09-01

    The 394 abstracted references on environmental restoration, nuclear facility decommissioning, uranium mill tailings management, and site remedial actions constitute the eleventh in a series of reports prepared annually for the US Department of Energy's Remedial Action Programs. Citations to foreign and domestic literature of all types -- technical reports, progress reports, journal articles, symposia proceedings, theses, books, patents, legislation, and research project descriptions -- have been included. The bibliography contains scientific, technical, economic, regulatory, and legal information pertinent to the US Department of Energy's Remedial Action Programs. Major sections are (1) Surplus Facilities Management Program, (2) Nuclear Facilities Decommissioning, (3)more » Formerly Utilized Sites Remedial Action Programs, (4) Facilities Contaminated with Naturally Occurring Radionuclides, (5) Uranium Mill Tailings Remedial Action Program, (6) Grand Junction Remedial Action Program, (7) Uranium Mill Tailings Management, (8) Technical Measurements Center, (9) Remedial Action Program, and (10) Environmental Restoration Program. Within these categories, references are arranged alphabetically by first author. Those references having no individual author are listed by corporate affiliation or by publication title. Indexes are provided for author, corporate affiliation, title word, publication description, geographic location, subject category, and keywords. This report is a product of the Remedial Action Program Information Center (RAPIC), which selects and analyzes information on remedial actions and relevant radioactive waste management technologies.« less

  12. Nuclear facility decommissioning and site remedial actions: A selected bibliography: Volume 8

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Owen, P.T.; Michelson, D.C.; Knox, N.P.

    1987-09-01

    The 553 abstracted references on nuclear facility decommissioning, uranium mill tailings management, and site remedial actions constitute the eighth in a series of reports. Foreign and domestic literature of all types - technical reports, progress reports, journal articles, symposia proceedings, theses, books, patents, legislation, and research project descriptions - has been included. The bibliography contains scientific, technical, economic, regulatory, and legal information pertinent to the US Department of energy's remedial action program. Major chapters are Surplus Facilities Management Program, Nuclear Facilities Decommissioning, Formerly Utilized Sites Remedial Action Program, Facilities Contaminated with Naturally Occurring Radionuclides, Uranium Mill Tailings Remedial Action Program,more » Uranium Mill Tailings Management, Technical Measurements Center, and General Remedial Action Program Studies. Chapter sections for chapters 1, 2, 5, and 6 include Design, Planning, and Regulations; Environmental Studies and Site Surveys; Health, Safety, and Biomedical Studies; Decontamination Studies; Dismantlement and Demolition; Site Stabilization and Reclamation; Waste Disposal; Remedial Action Experience; and General Studies. Within these categories, references are arranged alphabetically by first author. Those references having no individual author are listed by corporate affiliation or by publication description. Indexes are provided for author, corporate affiliation, title word, publication description, geographic location, and keywords. The appendix contains a list of frequently used acronyms and abbreviations.« less

  13. Infectious diseases related aeromedical evacuation of French soldiers in a level 4 military treatment facility: a ten year retrospective analysis.

    PubMed

    Rapp, C; Aoun, O; Ficko, C; Andriamanantena, D; Flateau, C

    2014-01-01

    Infectious diseases are a frequent cause of morbidity in French troops deployed abroad. They are usually minor in severity and managed by field practitioners. We aimed to describe the etiological spectrum of travel-related infections in French soldiers evacuated to a level 4 military treatment facility. We evaluated the diagnoses of all service members who were medically evacuated from abroad to our infectious diseases department from January 1, 2004 to October 30, 2013. One hundred and twenty five cases, median age 32 years were referred, 117 (94%) were male and 78 (62%) were from the Army. Main areas of deployment were Africa in 80 cases (64%), Afghanistan in 15 cases (12%), and French Guiana in 10 cases (8%). Median time between initial consultation and hospitalization in the reference center was 5 days (IQ 2-7 d). Thirty (24%) immediate aeromedical evacuations were carried out. The top five diagnoses were Plasmodium falciparum malaria (30), fever of unknown origin (15), cerebro-meningeal infections (10), invasive amebiasis (9), and HIV primary infections (9). Thirteen individuals were admitted in ICU. No death was recorded. Infectious diseases were a rare of cause of medevac. Most of them were preventable. Lethal etiologies were represented by malaria and cerebro-meningeal infections. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Investigation of Workplace-like Calibration Fields via a Deuterium-Tritium (D-T) Neutron Generator.

    PubMed

    Mozhayev, Andrey V; Piper, Roman K; Rathbone, Bruce A; McDonald, Joseph C

    2017-04-01

    Radiation survey meters and personal dosimeters are typically calibrated in reference neutron fields based on conventional radionuclide sources, such as americium-beryllium (Am-Be) or californium-252 (Cf), either unmodified or heavy-water moderated. However, these calibration neutron fields differ significantly from the workplace fields in which most of these survey meters and dosimeters are being used. Although some detectors are designed to yield an approximately dose-equivalent response over a particular neutron energy range, the response of other detectors is highly dependent upon neutron energy. This, in turn, can result in significant over- or underestimation of the intensity of neutron radiation and/or personal dose equivalent determined in the work environment. The use of simulated workplace neutron calibration fields that more closely match those present at the workplace could improve the accuracy of worker, and workplace, neutron dose assessment. This work provides an overview of the neutron fields found around nuclear power reactors and interim spent fuel storage installations based on available data. The feasibility of producing workplace-like calibration fields in an existing calibration facility has been investigated via Monte Carlo simulations. Several moderating assembly configurations, paired with a neutron generator using the deuterium tritium (D-T) fusion reaction, were explored.

  15. Exploration of the susceptibility of AChE from the poultry red mite Dermanyssus gallinae (Acari: Mesostigmata) to organophosphates in field isolates from France.

    PubMed

    Roy, Lise; Chauve, Claude; Delaporte, Jean; Inizan, Gilbert; Buronfosse, Thierry

    2009-06-01

    The red fowl mite Dermanyssus gallinae (De Geer, 1778) is a hematophagous mite species, which is very commonly found in layer facilities in Europe. The economic and animal health impact of this parasite is quite important. In laying hen houses, organophosphates are almost the only legally usable chemicals. Detecting a target resistance can be useful in order to limit the emergence of resistant populations. The acetylcholinesterase (AChE) activity and the enzyme sensitivity to paraoxon was investigated in 39 field samples and compared to a susceptible reference strain (SSK). Insensitivity factor values (expressed as IC50 ratio) obtained from field isolates compared to SSK revealed some polymorphism but not exceeding a 6-fold difference. The kinetic characteristics of AChE from some field samples showed some difference in KM values for acetylthiocholine and inhibition kinetics performed with diethyl paraoxon exhibited a 5.5-fold difference in the bimolecular rate constant in one field isolate. Taken together, these data suggested that differences in AChE susceptibility to organophosphates may exist in D. gallinae but no resistant population was found.

  16. Gender Comparison in Referrals and Treatment Completion to Residential and Outpatient Alcohol Treatment.

    PubMed

    Bazargan-Hejazi, Shahrzad; De Lucia, Valory; Pan, Deyu; Mojtahedzadeh, Mona; Rahmani, Elham; Jabori, Sinan; Zahmatkesh, Golara; Bazargan, Mohsen

    2016-01-01

    Residential treatment for alcoholism is associated with high completion rates for clients, yet there appear to be gender disparities in patient referrals and treatment completion rates. We studied whether (A) gender is associated with differential patient placement to outpatient vs. residential treatment facilities and (B) completion rates differ by gender. In this cross-sectional study, we analyzed the admission and discharge data from 185 publicly funded substance abuse treatment facilities across Los Angeles County between 2005 and 2010. Among the 33,745 studied cases, women were referred to residential treatment facilities less frequently than men (75% vs. 66%). The adjusted results derived from logistic regression models confirmed that females were more likely to be referred to outpatient treatment than to residential treatment facilities (odds ratio [OR]: 1.15, 95% confidence interval [CI]: 1.05-1.26). In addition, we observed that compared to White/Caucasian patients, all other races were associated with more referral to outpatient facilities (ie, less referral to residential facilities), indicating a racial disparity on the top of the observed gender disparity. However, there was no significant link between gender and treatment completion rates (OR: 0.93, 95% CI: 0.86-1.00). Women seem to have treatment completion rates comparable to men, yet they are less likely to be referred to residential treatment facilities. Hence, there still remains a gender disparity in alcoholic patient referrals. Further studies should delineate which specific therapeutic aspects and programmatic components of women-focused treatments are essential to augment positive treatment outcomes.

  17. Evaluation of parameters of Black Hole, stellar cluster and dark matter distribution from bright star orbits in the Galactic Center

    NASA Astrophysics Data System (ADS)

    Zakharov, Alexander

    It is well-known that one can evaluate black hole (BH) parameters (including spin) analyz-ing trajectories of stars around BH. A bulk distribution of matter (dark matter (DM)+stellar cluster) inside stellar orbits modifies trajectories of stars, namely, generally there is a apoas-tron shift in direction which opposite to GR one, even now one could put constraints on DM distribution and BH parameters and constraints will more stringent in the future. Therefore, an analyze of bright star trajectories provides a relativistic test in a weak gravitational field approximation, but in the future one can test a strong gravitational field near the BH at the Galactic Center with the same technique due to a rapid progress in observational facilities. References A. Zakharov et al., Phys. Rev. D76, 062001 (2007). A.F. Zakharov et al., Space Sci. Rev. 148, 301313(2009).

  18. 76 FR 18748 - Gulf South Pipeline Company, LP; Notice of Application

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-05

    ... abandon by sale to Boardwalk Field Services, LLC (Field Services) the Pettus Lateral Facilities in Bee and... taps, and other associated facilities located in Bee and Refugio Counties, to Field Services. Gulf...

  19. 49 CFR 193.2005 - Applicability.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY LIQUEFIED NATURAL GAS FACILITIES..., design, installation, or construction of LNG facilities (including material incorporated by reference in...

  20. Evaluation of a laboratory quality assurance pilot programme for malaria diagnostics in low-transmission areas of Kenya, 2013.

    PubMed

    Wanja, Elizabeth; Achilla, Rachel; Obare, Peter; Adeny, Rose; Moseti, Caroline; Otieno, Victor; Morang'a, Collins; Murigi, Ephantus; Nyamuni, John; Monthei, Derek R; Ogutu, Bernhards; Buff, Ann M

    2017-05-25

    One objective of the Kenya National Malaria Strategy 2009-2017 is scaling access to prompt diagnosis and effective treatment. In 2013, a quality assurance (QA) pilot was implemented to improve accuracy of malaria diagnostics at selected health facilities in low-transmission counties of Kenya. Trends in malaria diagnostic and QA indicator performance during the pilot are described. From June to December 2013, 28 QA officers provided on-the-job training and mentoring for malaria microscopy, malaria rapid diagnostic tests and laboratory QA/quality control (QC) practices over four 1-day visits at 83 health facilities. QA officers observed and recorded laboratory conditions and practices and cross-checked blood slides for malaria parasite presence, and a portion of cross-checked slides were confirmed by reference laboratories. Eighty (96%) facilities completed the pilot. Among 315 personnel at pilot initiation, 13% (n = 40) reported malaria diagnostics training within the previous 12 months. Slide positivity ranged from 3 to 7%. Compared to the reference laboratory, microscopy sensitivity ranged from 53 to 96% and positive predictive value from 39 to 53% for facility staff and from 60 to 96% and 52 to 80%, respectively, for QA officers. Compared to reference, specificity ranged from 88 to 98% and negative predictive value from 98 to 99% for health-facility personnel and from 93 to 99% and 99%, respectively, for QA officers. The kappa value ranged from 0.48-0.66 for facility staff and 0.57-0.84 for QA officers compared to reference. The only significant test performance improvement observed for facility staff was for specificity from 88% (95% CI 85-90%) to 98% (95% CI 97-99%). QA/QC practices, including use of positive-control slides, internal and external slide cross-checking and recording of QA/QC activities, all increased significantly across the pilot (p < 0.001). Reference material availability also increased significantly; availability of six microscopy job aids and seven microscopy standard operating procedures increased by a mean of 32 percentage points (p < 0.001) and 38 percentage points (p < 0.001), respectively. Significant gains were observed in malaria QA/QC practices over the pilot. However, these advances did not translate into improved accuracy of malaria diagnostic performance perhaps because of the limited duration of the QA pilot implementation.

  1. Changing the role of the traditional birth attendant in Somaliland.

    PubMed

    Pyone, Thidar; Adaji, Sunday; Madaj, Barbara; Woldetsadik, Tadesse; van den Broek, Nynke

    2014-10-01

    To explore the feasibility of changing the role of the traditional birth attendant (TBA) to act as birth companion and promoter of skilled birth attendance. Between 2008 and 2012, 75 TBAs received 3days of training and were paid US $5 for each patient brought to any of five healthcare facilities in Maroodi Jeex, Somaliland. Health facilities were upgraded (infrastructure, drugs and equipment, staff training, and incentivization). Eight key informant interviews (KIIs) and 10 focus group discussions (FGDs) involving 32 TBAs and 32 mothers were conducted. A framework approach was used for analysis. TBAs adopted their new role easily; instead of conducting home births and referring women to a facility only at onset of complications, they accompanied or referred mothers to a nearby facility for delivery, prenatal care, or postnatal care. Both TBAs and mothers accepted this new role, resulting in increased deliveries at health facilities. Facilitating factors included the creation of an enabling environment at the health facility, acceptance of the TBA by health facility staff, and monetary incentivization. Changing the role of the TBA to support facility-based delivery is feasible and acceptable. Further research is needed to see whether this is replicable and can be scaled-up. Copyright © 2014 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  2. 18 CFR 157.213 - Underground storage field facilities.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 18 Conservation of Power and Water Resources 1 2013-04-01 2013-04-01 false Underground storage... of the Natural Gas Act for Certain Transactions and Abandonment § 157.213 Underground storage field... operate facilities for the remediation and maintenance of an existing underground storage facility...

  3. 18 CFR 157.213 - Underground storage field facilities.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 18 Conservation of Power and Water Resources 1 2014-04-01 2014-04-01 false Underground storage... of the Natural Gas Act for Certain Transactions and Abandonment § 157.213 Underground storage field... operate facilities for the remediation and maintenance of an existing underground storage facility...

  4. Nuclear reference materials to meet the changing needs of the global nuclear community

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martin, H.R.; Gradle, C.G.; Narayanan, U.I.

    New Brunswick Laboratory (NBL) serves as the US Government`s Certifying Authority for nuclear reference materials and measurement calibration standards. In this role, NBL provides nuclear reference materials certified for chemical and/or isotopic compositions traceable to a nationally accepted, internationally compatible reference base. Emphasis is now changing as to the types of traceable nuclear reference materials needed as operations change within the Department of Energy (DOE) complex and at nuclear facilities around the world. Environmental and waste minimization issues, facilities and materials transitioning from processing to storage modes with corresponding changes in the types of measurements being performed, emphasis on requirementsmore » for characterization of waste materials, difficulties in transporting nuclear materials, and International factors, including International Atomic Energy Agency (IAEA) inspection of excess US nuclear materials, are all contributing influences. During these changing times, ft is critical that traceable reference materials be provided for calibration or validation of the performance of measurement systems. This paper will describe actions taken and planned to meet the changing reference material needs of the global nuclear community.« less

  5. Risk management technique for liquefied natural gas facilities

    NASA Technical Reports Server (NTRS)

    Fedor, O. H.; Parsons, W. N.

    1975-01-01

    Checklists have been compiled for planning, design, construction, startup and debugging, and operation of liquefied natural gas facilities. Lists include references to pertinent safety regulations. Methods described are applicable to handling of other hazardous materials.

  6. Storage and handling of aviation fuels at airports

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1988-01-01

    This standard covers the basic principles for the design of fuel handling facilities and equipment at airports. It provides a reference for the planning and operation of aviation fuel handling facilities and associated equipment.

  7. 26 CFR 49.4253-12 - Cross reference.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 16 2010-04-01 2010-04-01 true Cross reference. 49.4253-12 Section 49.4253-12 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) MISCELLANEOUS EXCISE TAXES FACILITIES AND SERVICES EXCISE TAXES Communications § 49.4253-12 Cross reference. For exemptions...

  8. Computer Based Training: Field Deployable Trainer and Shared Virtual Reality

    NASA Technical Reports Server (NTRS)

    Mullen, Terence J.

    1997-01-01

    Astronaut training has traditionally been conducted at specific sites with specialized facilities. Because of its size and nature the training equipment is generally not portable. Efforts are now under way to develop training tools that can be taken to remote locations, including into orbit. Two of these efforts are the Field Deployable Trainer and Shared Virtual Reality projects. Field Deployable Trainer NASA has used the recent shuttle mission by astronaut Shannon Lucid to the Russian space station, Mir, as an opportunity to develop and test a prototype of an on-orbit computer training system. A laptop computer with a customized user interface, a set of specially prepared CD's, and video tapes were taken to the Mir by Ms. Lucid. Based upon the feedback following the launch of the Lucid flight, our team prepared materials for the next Mir visitor. Astronaut John Blaha will fly on NASA/MIR Long Duration Mission 3, set to launch in mid September. He will take with him a customized hard disk drive and a package of compact disks containing training videos, references and maps. The FDT team continues to explore and develop new and innovative ways to conduct offsite astronaut training using personal computers. Shared Virtual Reality Training NASA's Space Flight Training Division has been investigating the use of virtual reality environments for astronaut training. Recent efforts have focused on activities requiring interaction by two or more people, called shared VR. Dr. Bowen Loftin, from the University of Houston, directs a virtual reality laboratory that conducts much of the NASA sponsored research. I worked on a project involving the development of a virtual environment that can be used to train astronauts and others to operate a science unit called a Biological Technology Facility (BTF). Facilities like this will be used to house and control microgravity experiments on the space station. It is hoped that astronauts and instructors will ultimately be able to share common virtual environments and, using telephone links, conduct interactive training from separate locations.

  9. 47 CFR 51.327 - Notice of network changes: Content of notice.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ..., but is not limited to, references to technical specifications, protocols, and standards regarding transmission, signaling, routing, and facility assignment as well as references to technical standards that...

  10. 47 CFR 51.327 - Notice of network changes: Content of notice.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ..., but is not limited to, references to technical specifications, protocols, and standards regarding transmission, signaling, routing, and facility assignment as well as references to technical standards that...

  11. 47 CFR 51.327 - Notice of network changes: Content of notice.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ..., but is not limited to, references to technical specifications, protocols, and standards regarding transmission, signaling, routing, and facility assignment as well as references to technical standards that...

  12. Advanced yellow fever virus genome detection in point-of-care facilities and reference laboratories.

    PubMed

    Domingo, Cristina; Patel, Pranav; Yillah, Jasmin; Weidmann, Manfred; Méndez, Jairo A; Nakouné, Emmanuel Rivalyn; Niedrig, Matthias

    2012-12-01

    Reported methods for the detection of the yellow fever viral genome are beset by limitations in sensitivity, specificity, strain detection spectra, and suitability to laboratories with simple infrastructure in areas of endemicity. We describe the development of two different approaches affording sensitive and specific detection of the yellow fever genome: a real-time reverse transcription-quantitative PCR (RT-qPCR) and an isothermal protocol employing the same primer-probe set but based on helicase-dependent amplification technology (RT-tHDA). Both assays were evaluated using yellow fever cell culture supernatants as well as spiked and clinical samples. We demonstrate reliable detection by both assays of different strains of yellow fever virus with improved sensitivity and specificity. The RT-qPCR assay is a powerful tool for reference or diagnostic laboratories with real-time PCR capability, while the isothermal RT-tHDA assay represents a useful alternative to earlier amplification techniques for the molecular diagnosis of yellow fever by field or point-of-care laboratories.

  13. Data protection, privacy.

    PubMed

    La Monaca, G; Schiralli, I

    2010-01-01

    The topic of data protection is referred closely to the concept of privacy--characterized by the American political philosophy in order to indicate a sphere recognized as personal, and therefore private or intimate, of the person, which exclude other individuals or society--whose protection has deep roots in the international right. The technological progress in the field of telecommunication has increased the facility of acquisition and spreading of information, the exchange of data, and the possibility of access to confidential information by other people. This made it made necessary the regulation of the management and the transfer of these information in order to protect individual rights and, on the other hand, an easy circulation of data for legitimate and useful goals.

  14. Towards an Integrated Model of the WEAVE Performance

    NASA Astrophysics Data System (ADS)

    Ham, S. J.; Dalton, G.

    2016-10-01

    WEAVE is a new facility instrument for the 4.2 m William Herschel Telescope (WHT). The instrument has a 2° field of view and covers a wavelength range of 366-950 nm with up to 960 simultaneous spectra in each observation. The spectrograph consists of a collimator mirror and two correcting lenses before a VPH grating and two 8-lens cameras. The two cameras have been designed to have the same lens shapes. Here we report on the development of detailed simulations for the verification of the whole data reduction procedure and analysis pipeline, and for the generation of high signal-to-noise reference images that can be used as fitting templates for fiber positions and PSF mapping.

  15. Response of a tissue equivalent proportional counter to neutrons

    NASA Technical Reports Server (NTRS)

    Badhwar, G. D.; Robbins, D. E.; Gibbons, F.; Braby, L. A.

    2002-01-01

    The absorbed dose as a function of lineal energy was measured at the CERN-EC Reference-field Facility (CERF) using a 512-channel tissue equivalent proportional counter (TEPC), and neutron dose equivalent response evaluated. Although there are some differences, the measured dose equivalent is in agreement with that measured by the 16-channel HANDI tissue equivalent counter. Comparison of TEPC measurements with those made by a silicon solid-state detector for low linear energy transfer particles produced by the same beam, is presented. The measurements show that about 4% of dose equivalent is delivered by particles heavier than protons generated in the conducting tissue equivalent plastic. c2002 Elsevier Science Ltd. All rights reserved.

  16. Geohydrologic conditions at the nuclear-fuels reprocessing plant and waste-management facilities at the Western New York Nuclear Service Center, Cattaraugus County, New York

    USGS Publications Warehouse

    Bergeron, M.P.; Kappel, W.M.; Yager, R.M.

    1987-01-01

    A nuclear-fuel reprocessing plant, a high-level radioactive liquid-waste tank complex, and related waste facilities occupy 100 hectares (ha) within the Western New York Nuclear Service Center near West Valley, N.Y. The facilities are underlain by glacial and postglacial deposits that fill an ancestrial bedrock valley. The main plant facilities are on an elevated plateau referred to as the north plateau. Groundwater on the north plateau moves laterally within a surficial sand and gravel from the main plant building to areas northeast, east, and southeast of the facilities. The sand and gravel ranges from 1 to 10 m thick and has a hydraulic conductivity ranging from 0.1 to 7.9 m/day. Two separate burial grounds, a 4-ha area for low-level radioactive waste disposal and a 2.9-ha area for disposal of higher-level waste are excavated into a clay-rich till that ranges from 22 to 28 m thick. Migration of an organic solvent from the area of higher level waste at shallow depth in the till suggests that a shallow, fractured, oxidized, and weathered till is a significant pathway for lateral movement of groundwater. Below this zone, groundwater moves vertically downward through the till to recharge a lacustrine silt and fine sand. Within the saturated parts of the lacustrine unit, groundwater moves laterally to the northeast toward Buttermilk Creek. Hydraulic conductivity of the till, based on field and laboratory analyses , ranges from 0.000018 to 0.000086 m/day. (USGS)

  17. NEUTRON MULTIPLICITY AND ACTIVE WELL NEUTRON COINCIDENCE VERIFICATION MEASUREMENTS PERFORMED FOR MARCH 2009 SEMI-ANNUAL DOE INVENTORY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dewberry, R.; Ayers, J.; Tietze, F.

    The Analytical Development (AD) Section field nuclear measurement group performed six 'best available technique' verification measurements to satisfy a DOE requirement instituted for the March 2009 semi-annual inventory. The requirement of (1) yielded the need for SRNL Research Operations Department Material Control & Accountability (MC&A) group to measure the Pu content of five items and the highly enrich uranium (HEU) content of two. No 14Q-qualified measurement equipment was available to satisfy the requirement. The AD field nuclear group has routinely performed the required Confirmatory Measurements for the semi-annual inventories for fifteen years using sodium iodide and high purity germanium (HpGe)more » {gamma}-ray pulse height analysis nondestructive assay (NDA) instruments. With appropriate {gamma}-ray acquisition modeling, the HpGe spectrometers can be used to perform verification-type quantitative assay for Pu-isotopics and HEU content. The AD nuclear NDA group is widely experienced with this type of measurement and reports content for these species in requested process control, MC&A booking, and holdup measurements assays Site-wide. However none of the AD HpGe {gamma}-ray spectrometers have been 14Q-qualified, and the requirement of reference 1 specifically excluded a {gamma}-ray PHA measurement from those it would accept for the required verification measurements. The requirement of reference 1 was a new requirement for which the Savannah River National Laboratory (SRNL) Research Operations Department (ROD) MC&A group was unprepared. The criteria for exemption from verification were: (1) isotope content below 50 grams; (2) intrinsically tamper indicating or TID sealed items which contain a Category IV quantity of material; (3) assembled components; and (4) laboratory samples. Therefore all (SRNL) Material Balance Area (MBA) items with greater than 50 grams total Pu or greater than 50 grams HEU were subject to a verification measurement. The pass/fail criteria of reference 7 stated 'The facility will report measured values, book values, and statistical control limits for the selected items to DOE SR...', and 'The site/facility operator must develop, document, and maintain measurement methods for all nuclear material on inventory'. These new requirements exceeded SRNL's experience with prior semi-annual inventory expectations, but allowed the AD nuclear field measurement group to demonstrate its excellent adaptability and superior flexibility to respond to unpredicted expectations from the DOE customer. The requirements yielded five SRNL items subject to Pu verification and two SRNL items subject to HEU verification. These items are listed and described in Table 1.« less

  18. US Fish and Wildlife Service biomonitoring operations manual, Appendices A--K

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gianotto, D.F.; Rope, R.C.; Mondecar, M.

    1993-04-01

    Volume 2 contains Appendices and Summary Sheets for the following areas: A-Legislative Background and Key to Relevant Legislation, B- Biomonitoring Operations Workbook, C-Air Monitoring, D-Introduction to the Flora and Fauna for Biomonitoring, E-Decontamination Guidance Reference Field Methods, F-Documentation Guidance, Sample Handling, and Quality Assurance/Quality Control Standard Operating Procedures, G-Field Instrument Measurements Reference Field Methods, H-Ground Water Sampling Reference Field Methods, I-Sediment Sampling Reference Field Methods, J-Soil Sampling Reference Field Methods, K-Surface Water Reference Field Methods. Appendix B explains how to set up strategy to enter information on the ``disk workbook``. Appendix B is enhanced by DE97006389, an on-line workbook formore » users to be able to make revisions to their own biomonitoring data.« less

  19. Effects of a coastal golf complex on water quality, periphyton, and seagrass

    USGS Publications Warehouse

    Lewis, M.A.; Boustany, R.G.; Dantin, D.D.; Quarles, R.L.; Moore, J.C.; Stanley, R.S.

    2002-01-01

    The objective of this study was to provide baseline information on the effects of a golf course complex on water quality, colonized periphyton, and seagrass meadows in adjacent freshwater, near-coastal, and wetland areas. The chemical and biological impacts of the recreational facility, which uses reclaimed municipal wastewater for irrigation, were limited usually to near-field areas and decreased seaward during the 2-year study. Concentrations of chromium, copper, and organochlorine pesticides were below detection in surface water, whereas mercury, lead, arsenic, and atrazine commonly occurred at all locations. Only mercury and lead exceeded water quality criteria. Concentrations of nutrients and chlorophyll a were greater in fairway ponds and some adjacent coastal areas relative to reference locations and Florida estuaries. Periphyton ash free dry weight and pigment concentrations statistically differed but not between reference and non-reference coastal areas. Biomass of Thalassia testudinum (turtle grass) was approximately 43% less in a meadow located adjacent to the golf complex (P < 0.05). The results of the study suggest that the effects of coastal golf courses on water quality may be primarily localized and limited to peripheral near-coastal areas. However, this preliminary conclusion needs additional supporting data. ?? 2002 Elsevier Science (USA).

  20. 43 CFR 3270.10 - What types of geothermal operations are governed by these utilization regulations?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... of geothermal resources. This includes: (1) Electrical generation facilities; (2) Direct use facilities; (3) Related utilization facility operations; (4) Actual and allocated well field production and injection; and (5) Related well field operations. (b) The utilization regulations in subparts 3270 through...

  1. Nuclear facility decommissioning and site remedial actions. Volume 6. A selected bibliography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Owen, P.T.; Michelson, D.C.; Knox, N.P.

    1985-09-01

    This bibliography of 683 references with abstracts on the subject of nuclear facility decommissioning, uranium mill tailings management, and site remedial actions is the sixth in a series of annual reports prepared for the US Department of Energy's Remedial Action Programs. Foreign as well as domestic literature of all types - technical reports, progress reports, journal articles, conference papers, symposium proceedings, theses, books, patents, legislation, and research project descriptions - has been included. The bibliography contains scientific (basic research as well as applied technology), economic, regulatory, and legal literature pertinent to the US Department of Energy's remedial action program. Majormore » chapters are: (1) Surplus Facilities Management Program; (2) Nuclear Facilities Decommissioning; (3) Formerly Utilized Sites Remedial Action Program; (4) Facilities Contaminated with Natural Radioactivity; (5) Uranium Mill Tailings Remedial Action Program; (6) Grand Junction Remedial Action Program; (7) Uranium Mill Tailings Management; (8) Technical Measurements Center; and (9) General Remedial Action Program Studies. Chapter sections for chapters 1, 2, 5, and 7 include Design, Planning, and Regulations; Environmental Studies and Site Surveys; Health, Safety, and Biomedical Studies; Decontamination Studies; Dismantlement and Demolition; Site Stabilization and Reclamation; Waste Disposal; Remedial Action Experience; and General Studies. The references within each chapter or section are arranged alphabetically by leading author. References having no individual author are arranged by corporate affiliation or by publication description.« less

  2. 40 CFR Appendix IV to Part 266 - Reference Air Concentrations*

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 28 2013-07-01 2013-07-01 false Reference Air Concentrations* IV Appendix IV to Part 266 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES... MANAGEMENT FACILITIES Pt. 266, App. IV Appendix IV to Part 266—Reference Air Concentrations* Constituent CAS...

  3. 40 CFR Appendix IV to Part 266 - Reference Air Concentrations*

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 27 2014-07-01 2014-07-01 false Reference Air Concentrations* IV Appendix IV to Part 266 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES... MANAGEMENT FACILITIES Pt. 266, App. IV Appendix IV to Part 266—Reference Air Concentrations* Constituent CAS...

  4. 40 CFR Appendix IV to Part 266 - Reference Air Concentrations*

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 27 2011-07-01 2011-07-01 false Reference Air Concentrations* IV Appendix IV to Part 266 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES... MANAGEMENT FACILITIES Pt. 266, App. IV Appendix IV to Part 266—Reference Air Concentrations* Constituent CAS...

  5. 40 CFR Appendix IV to Part 266 - Reference Air Concentrations*

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 26 2010-07-01 2010-07-01 false Reference Air Concentrations* IV Appendix IV to Part 266 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES... MANAGEMENT FACILITIES Pt. 266, App. IV Appendix IV to Part 266—Reference Air Concentrations* Constituent CAS...

  6. 40 CFR 792.105 - Test, control, and reference substance characterization.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 31 2010-07-01 2010-07-01 true Test, control, and reference substance... shall be determined by the testing facility or the sponsor before the experimental start date. The stability of the test, control or reference substance shall be determined before the experimental start date...

  7. Hazardous Waste Generator Regulations: A User-Friendly Reference Document

    EPA Pesticide Factsheets

    User-friendly reference to assist EPA and state staff, industrial facilities generating and managing hazardous wastes as well as the general public, in locating and understanding RCRA hazardous waste generator regulations.

  8. Payload/GSE/data system interface: Users guide for the VPF (Vertical Processing Facility)

    NASA Technical Reports Server (NTRS)

    1993-01-01

    Payload/GSE/data system interface users guide for the Vertical Processing Facility is presented. The purpose of the document is three fold. First, the simulated Payload and Ground Support Equipment (GSE) Data System Interface, which is also known as the payload T-0 (T-Zero) System is described. This simulated system is located with the Cargo Integration Test Equipment (CITE) in the Vertical Processing Facility (VPF) that is located in the KSC Industrial Area. The actual Payload T-0 System consists of the Orbiter, Mobile Launch Platforms (MLPs), and Launch Complex (LC) 39A and B. This is referred to as the Pad Payload T-0 System (Refer to KSC-DL-116 for Pad Payload T-0 System description). Secondly, information is provided to the payload customer of differences between this simulated system and the actual system. Thirdly, a reference guide of the VPF Payload T-0 System for both KSC and payload customer personnel is provided.

  9. Evaluation of new technologies for the LISA gravitational reference sensor using the UF torsion pendulum

    NASA Astrophysics Data System (ADS)

    Conklin, John; Chilton, Andrew; Olatunde, Taiwo; Apple, Stephen; Aitken, Michael; Ciani, Giacomo; Mueller, Guido

    2016-01-01

    The Laser Interferometer Space Antenna (LISA) is the most mature concept for detecting gravitational waves from space. The LISA design has been studied for more than 20 years as a joint effort between NASA and the European Space Agency. LISA consists of three Sun-orbiting spacecraft that form an equilateral triangle, with each side measuring 1-5 million kilometers in length. Each spacecraft houses two free-floating test masses, which are protected from all disturbing forces so that they follow pure geodesics. A single test mass together with its protective housing and associated components is referred to as a gravitational reference sensor. A drag-free control system is supplied with measurements of the test mass position from these sensors and commands external micronewton thrusters to force the spacecraft to fly in formation with the test masses. Laser interferometry is used to measure the minute variations in the distance, or light travel time, between these purely free-falling TMs, caused by gravitational waves. We have constructed a new torsion pendulum facility with a force sensitivity in the range of pN/Hz1/2 around 1 mHz for testing new gravitational reference sensor technologies. This experimental facility consists of a vacuum enclosed torsion pendulum that suspends mock-ups of the LISA test masses, surrounded by their electrode housings. With the aid of this facility, we are (a) developing a novel test mass charge control scheme based on ultraviolet LEDs, (b) examining alternate test mass and electrode housing coatings, and (c) evaluating alternate operational modes of the LISA gravitational reference sensor. This presentation will describe this facility and the development status of these new technologies.

  10. Site environmental report for Calendar Year 1994 on radiological and nonradiological parameters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1995-06-30

    Battelle Memorial Institute`s nuclear research facilities are currently being maintained in a surveillance and maintenance (S&M) mode with continual decontamination and decommissioning (D&D) activities being conducted under Department of Energy (DOE) Contract W-7405-ENG-92. These activities are referred to under the Contract as the Battelle Columbus Laboratories Decommissioning Project (BCLDP). Operations referenced in this report are performed in support of S&M and D&D activities. Battelle`s King Avenue facility is not considered in this report to the extent that the West Jefferson facility is. The source term at the King Avenue site is a small fraction of the source term at themore » West Jefferson site. Off site levels of radionuclides that could be attributed to the west Jefferson and King Avenue nuclear operations wereindistinguishable from background levels at specific locations where air, water, and direct radiation measurements were performed. Environmental monitoring continued to demonstrate compliance by Battelle with federal, state and local regulations. Routine, nonradiological activities performed include monitoring liquid effluents and monitoring the ground water system for the West Jefferson North site. Samples of various environmental media including air, water, grass, fish, field and garden crops, sediment and soil were collected from the region surrounding the two sites and analyzed.« less

  11. Management of information within emergencies departments in developing countries: analysis at the National Emergency Department in Benin.

    PubMed

    Ahanhanzo, Yolaine Glèlè; Kpozehouen, Alphonse; Sopoh, Ghislain; Sossa-Jérôme, Charles; Ouedraogo, Laurent; Wilmet-Dramaix, Michèle

    2016-01-01

    The management of health information is a key pillar in both emergencies reception and handling facilities, given the strategic position and the potential of these facilities within hospitals, and in the monitoring of public health and epidemiology. With the technological revolution, computerization made the information systems evolve in emergency departments, especially in developed countries, with improved performance in terms of care quality, productivity and patient satisfaction. This study analyses the situation of Benin in this field, through the case of the Academic Clinic of Emergency Department of the National University Teaching Hospital of Cotonou, the national reference hospital. The study is cross-sectional and evaluative. Collection techniques are literature review and structured interviews. The components rated are resources, indicators, data sources, data management and the use-dissemination of the information through a model adapted from Health Metrics Network framework. We used quantitative and qualitative analysis. The absence of a regulatory framework restricts the operation of the system in all components and accounts for the lack and inadequacy of the dedicated resources. Dedication of more resources for this system for crucial needs such as computerization requires sensitization and greater awareness of the administrative authorities about the fact that an effective health information management system is of prime importance in this type of facility.

  12. 30. ELEVATION OF ARVFS FIELD TEST FACILITY SHOWING VIEW OF ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    30. ELEVATION OF ARVFS FIELD TEST FACILITY SHOWING VIEW OF SOUTH SIDE OF FACILITY, INCLUDING BUNKER, CABLE CHASE, SHIELDING TANK, AND FRAME ASSEMBLY. F.C. TORKELSON DRAWING NUMBER 842-ARVFS-701-2. INEL INDEX CODE NUMBER: 075 0701 851 151971. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID

  13. 30 CFR 285.825 - When must I assess my facilities?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Section 285.825 Mineral Resources BUREAU OF OCEAN ENERGY MANAGEMENT, REGULATION, AND ENFORCEMENT... CONTINENTAL SHELF Environmental and Safety Management, Inspections, and Facility Assessments for Activities... and Constructing Fixed Offshore Platforms—Working Stress Design (incorporated by reference, as...

  14. 40 CFR 270.310 - What equipment information must I keep at my facility?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... mechanical seals). (b) For facilities that cannot install a closed-vent system and control device to comply... Gaseous Emissions” (incorporated by reference as specified in 40 CFR 260.11) or other engineering texts...

  15. An Annotated List of Marine Stations Suitable for Field Courses in Carbonate Geology and Tropical Marine Sciences.

    ERIC Educational Resources Information Center

    Kaplan, Eugene H.

    1980-01-01

    Listed are field stations in the Caribbean and Florida-Bahamas which are suitable for classes in field geology and tropical marine science. Each field station is described by listing the name of the institution, description of accommodations, library facilities, laboratory facilities, boats, classrooms, motor vehicles, study areas, scuba, and…

  16. TWO NEW SINGLE-EXPOSURE, MULTI-DETECTOR NEUTRON SPECTROMETERS FOR RADIATION PROTECTION APPLICATIONS IN WORKPLACE MONITORING.

    PubMed

    Gómez-Ros, J M; Bedogni, R; Bortot, D; Domingo, C; Esposito, A; Introini, M V; Lorenzoli, M; Mazzitelli, G; Moraleda, M; Pola, A; Sacco, D

    2017-04-01

    This communication describes two new instruments, based on multiple active thermal neutron detectors arranged within a single moderator, that permit to unfold the neutron spectrum (from thermal to hundreds of MeV) and to determine the corresponding integral quantities with only one exposure. This makes them especially advantageous for neutron field characterisation and workplace monitoring in neutron-producing facilities. One of the devices has spherical geometry and nearly isotropic response, the other one has cylindrical symmetry and it is only sensitive to neutrons incident along the cylinder axis. In both cases, active detectors have been specifically developed looking for the criteria of miniaturisation, high sensitivity, linear response and good photon rejection. The calculated response matrix has been validated by experimental irradiations in neutron reference fields with a global uncertainty of 3%. The measurements performed in realistic neutron fields permitted to determine the neutron spectra and the integral quantities, in particular H*(10). © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. A New Facility for Testing Superconducting Solenoid Magnets with Large Fringe Fields at Fermilab

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Orris, D.; Carcagno, R.; Nogiec, J.

    2013-09-01

    Testing superconducting solenoid with no iron flux return can be problematic for a magnet test facility due to the large magnetic fringe fields generated. These large external fields can interfere with the operation of equipment while precautions must be taken for personnel supporting the test. The magnetic forces between the solenoid under test and the external infrastructure must also be taken under consideration. A new test facility has been designed and built at Fermilab specifically for testing superconducting magnets with large external fringe fields. This paper discusses the test stand design, capabilities, and details of the instrumentation and controls withmore » data from the first solenoid tested in this facility: the Muon Ionization Cooling Experiment (MICE) coupling coil.« less

  18. Literature Related to Planning, Design and Construction of Science Facilities.

    ERIC Educational Resources Information Center

    National Science Foundation, Washington, DC.

    A list of the articles and papers in the science facilities collection of the Architectural Services Staff is presented. It has been prepared to serve as a bibliography that may be useful to persons searching for data on the design of science facilities, and as a means of informing such persons of the material available for reference in the…

  19. DTT: a divertor tokamak test facility for the study of the power exhaust issues in view of DEMO

    NASA Astrophysics Data System (ADS)

    Albanese, R.; WPDTT2 Team; DTT Project Proposal Contributors, the

    2017-01-01

    In parallel with the programme to optimize the operation with a conventional divertor based on detached conditions to be tested on the ITER device, a project has been launched to investigate alternative power exhaust solutions for DEMO, aimed at the definition and the design of a divertor tokamak test facility (DTT). The DTT project proposal refers to a set of parameters selected so as to have edge conditions as close as possible to DEMO, while remaining compatible with DEMO bulk plasma performance in terms of dimensionless parameters and given constraints. The paper illustrates the DTT project proposal, referring to a 6 MA plasma with a major radius of 2.15 m, an aspect ratio of about 3, an elongation of 1.6-1.8, and a toroidal field of 6 T. This selection will guarantee sufficient flexibility to test a wide set of divertor concepts and techniques to cope with large heat loads, including conventional tungsten divertors; liquid metal divertors; both conventional and advanced magnetic configurations (including single null, snow flake, quasi snow flake, X divertor, double null); internal coils for strike point sweeping and control of the width of the scrape-off layer in the divertor region; and radiation control. The Poloidal Field system is planned to provide a total flux swing of more than 35 Vs, compatible with a pulse length of more than 100 s. This is compatible with the mission of studying the power exhaust problem and is obtained using superconducting coils. Particular attention is dedicated to diagnostics and control issues, especially those relevant for plasma control in the divertor region, designed to be as compatible as possible with a DEMO-like environment. The construction is expected to last about seven years, and the selection of an Italian site would be compatible with a budget of 500 M€.

  20. Spanish methodological approach for biosphere assessment of radioactive waste disposal.

    PubMed

    Agüero, A; Pinedo, P; Cancio, D; Simón, I; Moraleda, M; Pérez-Sánchez, D; Trueba, C

    2007-10-01

    The development of radioactive waste disposal facilities requires implementation of measures that will afford protection of human health and the environment over a specific temporal frame that depends on the characteristics of the wastes. The repository design is based on a multi-barrier system: (i) the near-field or engineered barrier, (ii) far-field or geological barrier and (iii) the biosphere system. Here, the focus is on the analysis of this last system, the biosphere. A description is provided of conceptual developments, methodological aspects and software tools used to develop the Biosphere Assessment Methodology in the context of high-level waste (HLW) disposal facilities in Spain. This methodology is based on the BIOMASS "Reference Biospheres Methodology" and provides a logical and systematic approach with supplementary documentation that helps to support the decisions necessary for model development. It follows a five-stage approach, such that a coherent biosphere system description and the corresponding conceptual, mathematical and numerical models can be built. A discussion on the improvements implemented through application of the methodology to case studies in international and national projects is included. Some facets of this methodological approach still require further consideration, principally an enhanced integration of climatology, geography and ecology into models considering evolution of the environment, some aspects of the interface between the geosphere and biosphere, and an accurate quantification of environmental change processes and rates.

  1. Shuttle Return-to-Flight IH-108 Aerothermal Test at CUBRC - Flow Field Calibration and CFD

    NASA Technical Reports Server (NTRS)

    Lau, Kei Y.; Holden, Michael

    2010-01-01

    This paper discusses one specific aspect of the Shuttle Retrun-To-Flight IH-108 Aerothermal Test at CUBRC, the test flow field calibration. It showed the versatility of the CUBRC LENS II wind tunnel for an aerothermal test with unique and demanding requirements. CFD analyses were used effectively to extend the test range at the low end of the Mach range. It demonstrated how ground test facility and CFD synergy can be utilitzed iteratively to enhance the confidence in the fedility of both tools. It addressed the lingering concerns of the aerothermal community on use of inpulse facility and CFD analysis. At the conclusion of the test program, members from the NASA Marshall (MSFC), CUBRC and USA (United Space Alliance) Consultants (The Grey Beards) were asked to independently verify the flight scaling data generated by Boeing for flight certification of the re-designed external tank (ET) components. The blind test comparison showed very good results. A more comprehensive discussion of the topics in this paper can be found in Chapter 6 of Reference [1]. The overall aspect of the test program has been discussed in an AIAA paper by Tim Wadhams [2]. The Shuttle Ascent Stack performance and related issues discussed in the Report [1] are not included in this paper. No ITAR data is included in this paper.

  2. Challenges in the Management and Stewardship of Airborne Observational Data at the National Center for Atmospheric Research (NCAR) Earth Observing Laboratory (EOL)

    NASA Astrophysics Data System (ADS)

    Aquino, J.; Daniels, M. D.

    2015-12-01

    The National Science Foundation (NSF) provides the National Center for Atmospheric Research (NCAR) Earth Observing Laboratory (EOL) funding for the operation, maintenance and upgrade of two research aircraft: the NSF/NCAR High-performance Instrumented Airborne Platform for Environmental Research (HIAPER) Gulfstream V and the NSF/NCAR Hercules C-130. A suite of in-situ and remote sensing airborne instruments housed at the EOL Research Aviation Facility (RAF) provide a basic set of measurements that are typically deployed on most airborne field campaigns. In addition, instruments to address more specific research requirements are provided by collaborating participants from universities, industry, NASA, NOAA or other agencies (referred to as Principal Investigator, or PI, instruments). At the 2014 AGU Fall Meeting, a poster (IN13B-3639) was presented outlining the components of Airborne Data Management included field phase data collection, formats, data archival and documentation, version control, storage practices, stewardship and obsolete data formats, and public data access. This talk will cover lessons learned, challenges associated with the above components, and current developments to address these challenges, including: tracking data workflows for aircraft instrumentation to facilitate identification, and correction, of gaps in these workflows; implementation of dataset versioning guidelines; and assignment of Digital Object Identifiers (DOIs) to data and instrumentation to facilitate tracking data and facility use in publications.

  3. Users Guide for the National Transonic Facility Research Data System

    NASA Technical Reports Server (NTRS)

    Foster, Jean M.; Adcock, Jerry B.

    1996-01-01

    The National Transonic Facility is a complex cryogenic wind tunnel facility. This report briefly describes the facility, the data systems, and the instrumentation used to acquire research data. The computational methods and equations are discussed in detail and many references are listed for those who need additional technical information. This report is intended to be a user's guide, not a programmer's guide; therefore, the data reduction code itself is not documented. The purpose of this report is to assist personnel involved in conducting a test in the National Transonic Facility.

  4. Medicare and Medicaid programs; fire safety requirements for certain health care facilities. Final rule.

    PubMed

    2003-01-10

    This final rule amends the fire safety standards for hospitals, long-term care facilities, intermediate care facilities for the mentally retarded, ambulatory surgery centers, hospices that provide inpatient services, religious nonmedical health care institutions, critical access hospitals, and Programs of All-Inclusive Care for the Elderly facilities. Further, this final rule adopts the 2000 edition of the Life Safety Code and eliminates references in our regulations to all earlier editions.

  5. Energy - Sandia National Laboratories

    Science.gov Websites

    ; Components Compatibility Hydrogen Behavior Quantitative Risk Assessment Technical Reference for Hydrogen Combustion jbei Facilities Algae Testbed Battery Abuse Testing Laboratory Center for Infrastructure Research and Innovation Combustion Research Facility Joint BioEnergy Institute Close Energy Research Programs

  6. Earth Science - Sandia Energy

    Science.gov Websites

    ; Components Compatibility Hydrogen Behavior Quantitative Risk Assessment Technical Reference for Hydrogen Combustion jbei Facilities Algae Testbed Battery Abuse Testing Laboratory Center for Infrastructure Research and Innovation Combustion Research Facility Joint BioEnergy Institute Close Energy Research Programs

  7. Stationary Power - Sandia Energy

    Science.gov Websites

    ; Components Compatibility Hydrogen Behavior Quantitative Risk Assessment Technical Reference for Hydrogen Combustion jbei Facilities Algae Testbed Battery Abuse Testing Laboratory Center for Infrastructure Research and Innovation Combustion Research Facility Joint BioEnergy Institute Close Energy Research Programs

  8. Transportation Energy - Sandia Energy

    Science.gov Websites

    ; Components Compatibility Hydrogen Behavior Quantitative Risk Assessment Technical Reference for Hydrogen Combustion jbei Facilities Algae Testbed Battery Abuse Testing Laboratory Center for Infrastructure Research and Innovation Combustion Research Facility Joint BioEnergy Institute Close Energy Research Programs

  9. Grid Modernization - Sandia Energy

    Science.gov Websites

    ; Components Compatibility Hydrogen Behavior Quantitative Risk Assessment Technical Reference for Hydrogen Combustion jbei Facilities Algae Testbed Battery Abuse Testing Laboratory Center for Infrastructure Research and Innovation Combustion Research Facility Joint BioEnergy Institute Close Energy Research Programs

  10. Description of a Ground Facility for Conducting Ionospheric Scintillation Measurements with the ATS-5 Spacecraft

    DOT National Transportation Integrated Search

    1974-07-01

    Some of the capabilities of the DOT/TSC Westford Propagation Facility located in Westford Massachusetts as they relate to ionospheric measurements will be described. A detailed bibliography of over 400 references is supplied.

  11. The Air Force's central reference laboratory: maximizing service while minimizing cost.

    PubMed

    Armbruster, D A

    1991-11-01

    The Laboratory Services Branch (Epi Lab) of the Epidemiology Division, Brooks AFB, Texas, is designated by regulation to serve as the Air Force's central reference laboratory, providing clinical laboratory testing support to all Air Force medical treatment facilities (MTFs). Epi Lab recognized that it was not offering the MTFs a service comparable to civilian reference laboratories and that, as a result, the Air Force medical system was spending hundreds of thousands of dollars yearly for commercial laboratory support. An in-house laboratory upgrade program was proposed to and approved by the USAF Surgeon General, as a Congressional Efficiencies Add project, to launch a two-phase initiative consisting of a 1-year field trial of 30 MTFs, followed by expansion to another 60 MTFs. Major components of the program include overnight air courier service to deliver patient samples to Epi Lab, a mainframe computer laboratory information system and electronic reporting of results to the MTFs throughout the CONUS. Application of medical marketing concepts and the Total Quality Management (TQM) philosophy allowed Epi to provide dramatically enhanced reference service at a cost savings of about $1 million to the medical system. The Epi Lab upgrade program represents an innovative problem-solving approach, combining technical and managerial improvements, resulting in substantial patient care service and financial dividends. It serves as an example of successful application of TQM and marketing within the military medical system.

  12. Reference Pricing, Consumer Cost-Sharing, and Insurer Spending for Advanced Imaging Tests.

    PubMed

    Robinson, James C; Whaley, Christopher; Brown, Timothy T

    2016-12-01

    Fees charged for similar imaging tests often vary dramatically within the same market, leading to wide variation in insurer spending and consumer cost-sharing. Reference pricing is an insurance design that offers good coverage to patients up to a defined contribution limit but requires the patients who select high-priced facilities to pay the remainder out of pocket. To measure the association between implementation of reference pricing and patient choice of facility, test prices, out-of-pocket spending, and insurer spending for advanced imaging (CT and MRI) procedures. Difference-in-differences multivariable analysis of insurance claims data. Study included 4751 employees of a national grocery chain (treatment group) and 23,428 enrollees in the nation's largest private insurance plan (comparison group) that used CT or MRI tests between 2010 and 2013. Patient choice of facility, price paid per test, patient out-of-pocket cost-sharing, and employer spending. Compared with trends in prices paid by insurance enrollees not subject to reference pricing, and after adjusting for characteristics of tests and patients, implementation of reference pricing was associated with a 12.5% (95% CI, -25.0%, 2.1%) reduction in average price paid per test by the end of the second full year of the program for CT scans and a 10.5% (95% CI, -16.9%, 3.6%) for MRIs. Out-of-pocket cost-sharing by patients declined by $71,508 (13.8%). The savings accruing to employees amounted to 45.5% of total savings from reference pricing, with the remainder accruing to the employer. Implementation of reference pricing led to reductions in payments by both employer and employees.

  13. Facile solution synthesis of hexagonal Alq3 nanorods and their field emission properties.

    PubMed

    Hu, Jin-Song; Ji, Heng-Xing; Cao, An-Min; Huang, Zheng-Xi; Zhang, Yang; Wan, Li-Jun; Xia, An-Dong; Yu, Da-Peng; Meng, Xiang-Min; Lee, Shuit-Tong

    2007-08-07

    A facile self-assembly growth route assisted by surfactant has been developed to synthesize tris(8-hydroxyquinoline)aluminium (Alq(3)) nanorods with regular hexagonal shape and good crystallinity, which exhibit field-emission characteristics with a very low turn-on field of ca. 3.1 V microm(-1) and a high field-enhancement factor of ca. 1300.

  14. Comparison of the diagnostic accuracy of a rapid immunochromatographic test and the rapid plasma reagin test for antenatal syphilis screening in Mozambique.

    PubMed Central

    Montoya, Pablo J.; Lukehart, Sheila A.; Brentlinger, Paula E.; Blanco, Ana J.; Floriano, Florencia; Sairosse, Josefa; Gloyd, Stephen

    2006-01-01

    OBJECTIVE: Programmes to control syphilis in developing countries are hampered by a lack of laboratory services, delayed diagnosis, and doubts about current screening methods. We aimed to compare the diagnostic accuracy of an immunochromatographic strip (ICS) test and the rapid plasma reagin (RPR) test with the combined gold standard (RPR, Treponema pallidum haemagglutination assay and direct immunofluorescence stain done at a reference laboratory) for the detection of syphilis in pregnancy. METHODS: We included test results from 4789 women attending their first antenatal visit at one of six health facilities in Sofala Province, central Mozambique. We compared diagnostic accuracy (sensitivity, specificity, and positive and negative predictive values) of ICS and RPR done at the health facilities and ICS performed at the reference laboratory. We also made subgroup comparisons by human immunodeficiency virus (HIV) and malaria status. FINDINGS: For active syphilis, the sensitivity of the ICS was 95.3% at the reference laboratory, and 84.1% at the health facility. The sensitivity of the RPR at the health facility was 70.7%. Specificity and positive and negative predictive values showed a similar pattern. The ICS outperformed RPR in all comparisons (P<0.001). CONCLUSION: The diagnostic accuracy of the ICS compared favourably with that of the gold standard. The use of the ICS in Mozambique and similar settings may improve the diagnosis of syphilis in health facilities, both with and without laboratories. PMID:16501726

  15. Energy Fact Sheets - Sandia Energy

    Science.gov Websites

    ; Components Compatibility Hydrogen Behavior Quantitative Risk Assessment Technical Reference for Hydrogen Combustion jbei Facilities Algae Testbed Battery Abuse Testing Laboratory Center for Infrastructure Research and Innovation Combustion Research Facility Joint BioEnergy Institute Close Energy Research Programs

  16. 40 CFR 53.2 - General requirements for a reference method determination.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... part. Further, FRM samplers must be manufactured in an ISO 9001-registered facility, as defined in § 53... manufactured in an ISO 9001-registered facility, as defined in § 53.1 and as set forth in § 53.51. (b...

  17. Goddard Space Flight Center (GSFC) Flight Dynamics Facility (FDF) calibration of the Upper Atmosphere Research Satellite (UARS) sensors

    NASA Technical Reports Server (NTRS)

    Hashmall, J.; Garrick, J.

    1993-01-01

    Flight Dynamics Facility (FDF) responsibilities for calibration of Upper Atmosphere Research Satellite (UARS) sensors included alignment calibration of the fixed-head star trackers (FHST's) and the fine Sun sensor (FSS), determination of misalignments and scale factors for the inertial reference units (IRU's), determination of biases for the three-axis magnetometers (TAM's) and Earth sensor assemblies (ESA's), determination of gimbal misalignments of the Solar/Stellar Pointing Platform (SSPP), and field-of-view calibration for the FSS's mounted both on the Modular Attitude Control System (MACS) and on the SSPP. The calibrations, which used a combination of new and established algorithms, gave excellent results. Alignment calibration results markedly improved the accuracy of both ground and onboard Computer (OBC) attitude determination. SSPP calibration results allowed UARS to identify stars in the period immediately after yaw maneuvers, removing the delay required for the OBC to reacquire its fine pointing attitude mode. SSPP calibration considerably improved the pointing accuracy of the attached science instrument package. This paper presents a summary of the methods used and the results of all FDF UARS sensor calibration.

  18. Project C-018H, 242-A Evaporator/PUREX Plant Process Condensate Treatment Facility, functional design criteria. Revision 3

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sullivan, N.

    1995-05-02

    This document provides the Functional Design Criteria (FDC) for Project C-018H, the 242-A Evaporator and Plutonium-Uranium Extraction (PUREX) Plant Condensate Treatment Facility (Also referred to as the 200 Area Effluent Treatment Facility [ETF]). The project will provide the facilities to treat and dispose of the 242-A Evaporator process condensate (PC), the Plutonium-Uranium Extraction (PUREX) Plant process condensate (PDD), and the PUREX Plant ammonia scrubber distillate (ASD).

  19. Atom probe field ion microscopy and related topics: A bibliography 1993

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Godfrey, R.D.; Miller, M.K.; Russell, K.F.

    1994-10-01

    This bibliography, covering the period 1993, includes references related to the following topics: atom probe field ion microscopy (APFIM), field emission (FE), and field ion microscopy (FIM). Technique-oriented studies and applications are included. The references contained in this document were compiled from a variety of sources including computer searches and personal lists of publications. To reduce the length of this document, the references have been reduced to the minimum necessary to locate the articles. The references are listed alphabetically by authors, an Addendum of references missed in previous bibliographies is included.

  20. 20 CFR 416.1720 - Whom we refer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... Treatment of Alcoholism Or Drug Addiction § 416.1720 Whom we refer. We will refer you to an approved facility for treatment of your alcoholism or drug addiction if— (a) You are disabled; (b) You are not blind; (c) You are not 65 years old or older; and (d) Alcoholism or drug addiction is a contributing factor...

  1. 20 CFR 416.1720 - Whom we refer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... Treatment of Alcoholism Or Drug Addiction § 416.1720 Whom we refer. We will refer you to an approved facility for treatment of your alcoholism or drug addiction if— (a) You are disabled; (b) You are not blind; (c) You are not 65 years old or older; and (d) Alcoholism or drug addiction is a contributing factor...

  2. 20 CFR 416.1720 - Whom we refer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... Treatment of Alcoholism Or Drug Addiction § 416.1720 Whom we refer. We will refer you to an approved facility for treatment of your alcoholism or drug addiction if— (a) You are disabled; (b) You are not blind; (c) You are not 65 years old or older; and (d) Alcoholism or drug addiction is a contributing factor...

  3. 20 CFR 416.1720 - Whom we refer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... Treatment of Alcoholism Or Drug Addiction § 416.1720 Whom we refer. We will refer you to an approved facility for treatment of your alcoholism or drug addiction if— (a) You are disabled; (b) You are not blind; (c) You are not 65 years old or older; and (d) Alcoholism or drug addiction is a contributing factor...

  4. Physician ownership of physical therapy services. Effects on charges, utilization, profits, and service characteristics.

    PubMed

    Mitchell, J M; Scott, E

    1992-10-21

    To evaluate the effects of physician ownership of freestanding physical therapy and rehabilitation facilities on utilization, charges, profits, and three measures of service characteristics for physical therapy treatments. Statistical comparison by physician joint venture ownership status of freestanding physical therapy and comprehensive rehabilitation facilities providing physical therapy treatments in Florida. A total of 118 outpatient physical therapy facilities and 63 outpatient comprehensive rehabilitation facilities providing services in Florida during 1989. The data from the facilities were collected under a legislative mandate. Visits per patient, average revenue per patient, percent operating income, percent markup, profits per patient, licensed therapist time per visit, and licensed and nonlicensed medical worker time per visit. Visits per patient were 39% to 45% higher in joint venture facilities. Both gross and net revenue per patient were 30% to 40% higher in facilities owned by referring physicians. Percent operating income and percent markup were significantly higher in joint venture physical therapy and rehabilitation facilities. Licensed physical therapists and licensed therapist assistants employed in non-joint venture facilities spend about 60% more time per visit treating physical therapy patients than licensed therapists and licensed therapist assistants working in joint venture facilities. Joint ventures also generate more of their revenues from patients with well-paying insurance. Our results indicate that utilization, charges per patient, and profits are higher when physical therapy and rehabilitation facilities are owned by referring physicians. With respect to service characteristics, joint venture firms employ proportionately fewer licensed therapists and licensed therapist assistants to perform physical therapy, so that licensed professionals employed in joint venture businesses spend significantly less time per visit treating patients. These results should be of interest to the medical profession, third-party payers, and policymakers, all of whom are concerned about the consequences of physician self-referral arrangements.

  5. Retrofit of waste-to-energy facilities equipped with electrostatic precipitators. Volume II: Field and laboratory reports, Part 2 of 2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rigo, H.G.; Chandler, A.J.

    Volume II (part 2 of 2) of ''Retrofit of Waste-to-energy Facilities Equipped with Electrostatic Precipitators'' contains the field and laboratory reports, including: (1) field reports, (2) analytic laboratory reports, (3) chain of custody forms, and (4) TCLP laboratory reports.

  6. 10 CFR 770.5 - How does DOE notify persons and entities that defense nuclear facility real property is available...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... available for transfer for economic development? (a) Field Office Managers annually make available to... the availability of the list. (b) Upon request, Field Office Managers provide to interested persons... facilities that DOE has identified as appropriate for transfer for economic development. Field Office...

  7. 10 CFR 770.5 - How does DOE notify persons and entities that defense nuclear facility real property is available...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... available for transfer for economic development? (a) Field Office Managers annually make available to... the availability of the list. (b) Upon request, Field Office Managers provide to interested persons... facilities that DOE has identified as appropriate for transfer for economic development. Field Office...

  8. 30 CFR 285.825 - When must I assess my facilities?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Section 285.825 Mineral Resources MINERALS MANAGEMENT SERVICE, DEPARTMENT OF THE INTERIOR OFFSHORE... Safety Management, Inspections, and Facility Assessments for Activities Conducted Under SAPs, COPs and... Offshore Platforms—Working Stress Design (incorporated by reference, as specified in § 285.115). (b) You...

  9. EPA Facility Registry Service (FRS): OIL

    EPA Pesticide Factsheets

    This dataset contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link to the Oil database. The Oil database contains information on Spill Prevention, Control, and Countermeasure (SPCC) and Facility Response Plan (FRP) subject facilities to prevent and respond to oil spills. FRP facilities are referred to as substantial harm facilities due to the quantities of oil stored and facility characteristics. FRS identifies and geospatially locates facilities, sites or places subject to environmental regulations or of environmental interest. Using vigorous verification and data management procedures, FRS integrates facility data from EPA's national program systems, other federal agencies, and State and tribal master facility records and provides EPA with a centrally managed, single source of comprehensive and authoritative information on facilities. This data set contains the subset of FRS integrated facilities that link to Oil facilities once the Oil data has been integrated into the FRS database. Additional information on FRS is available at the EPA website https://www.epa.gov/enviro/facility-registry-service-frs.

  10. Electromagnetic Fields Associated with Commercial Solar Photovoltaic Electric Power Generating Facilities.

    PubMed

    Tell, R A; Hooper, H C; Sias, G G; Mezei, G; Hung, P; Kavet, R

    2015-01-01

    The southwest region of the United States is expected to experience an expansion of commercial solar photovoltaic generation facilities over the next 25 years. A solar facility converts direct current generated by the solar panels to three-phase 60-Hz power that is fed to the grid. This conversion involves sequential processing of the direct current through an inverter that produces low-voltage three-phase power, which is stepped up to distribution voltage (∼12 kV) through a transformer. This study characterized magnetic and electric fields between the frequencies of 0 Hz and 3 GHz at two facilities operated by the Southern California Edison Company in Porterville, CA and San Bernardino, CA. Static magnetic fields were very small compared to exposure limits established by IEEE and ICNIRP. The highest 60-Hz magnetic fields were measured adjacent to transformers and inverters, and radiofrequency fields from 5-100 kHz were associated with the inverters. The fields measured complied in every case with IEEE controlled and ICNIRP occupational exposure limits. In all cases, electric fields were negligible compared to IEEE and ICNIRP limits across the spectrum measured and when compared to the FCC limits (≥0.3 MHz).

  11. Tests of a solution-grown stilbene scintillator in mono-energetic neutron beams of 565 keV and 5 MeV

    NASA Astrophysics Data System (ADS)

    Dioni, Luca; Gressier, Vincent; Nardin, Gaëlle; Jacqmin, Robert; Stout, Brian; Sumini, Marco

    2018-02-01

    The results of measurements performed with a solution-grown stilbene scintillator placed in reference mono-energetic neutron fields are presented. The ∅ 25 mm organic scintillator was positioned in 5 MeV and 565 keV neutron fields delivered by the AIFIRA facility at CENBG. The goal of the experiment was to assess the performance of the solution-grown stilbene crystal (n- γ discrimination, response, anisotropy, sensitivity) relative to that of a BC501A liquid scintillator of larger size. Neutron pulse height spectra after gamma discrimination are compared. The results show that the stilbene crystal not only has a better discrimination capability than the BC501A (35% higher FoM) at 5 MeV, but is also able to separate neutrons from gamma-rays at 565 keV and below, a range where the BC501A is inoperative. This study also confirms the anisotropy of the crystal response, as already observed by other groups at different energies.

  12. PARTICLE IMAGE VELOCIMETRY MEASUREMENTS IN A REPRESENTATIVE GAS-COOLED PRISMATIC REACTOR CORE MODEL: FLOW IN THE COOLANT CHANNELS AND INTERSTITIAL BYPASS GAPS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thomas E. Conder; Richard Skifton; Ralph Budwig

    Core bypass flow is one of the key issues with the prismatic Gas Turbine-Modular Helium Reactor, and it refers to the coolant that navigates through the interstitial, non-cooling passages between the graphite fuel blocks instead of traveling through the designated coolant channels. To determine the bypass flow, a double scale representative model was manufactured and installed in the Matched Index-of-Refraction flow facility; after which, stereo Particle Image Velocimetry (PIV) was employed to measure the flow field within. PIV images were analyzed to produce vector maps, and flow rates were calculated by numerically integrating over the velocity field. It was foundmore » that the bypass flow varied between 6.9-15.8% for channel Reynolds numbers of 1,746 and 4,618. The results were compared to computational fluid dynamic (CFD) pre-test simulations. When compared to these pretest calculations, the CFD analysis appeared to under predict the flow through the gap.« less

  13. The European network of Biosafety-Level-4 laboratories: enhancing European preparedness for new health threats.

    PubMed

    Nisii, C; Castilletti, C; Di Caro, A; Capobianchi, M R; Brown, D; Lloyd, G; Gunther, S; Lundkvist, A; Pletschette, M; Ippolito, G

    2009-08-01

    Emerging and re-emerging infections and possible bioterrorism acts will continue to challenge both the medical community and civilian populations worldwide, urging health authorities to respond rapidly and effectively. Established in 2005, the European Community (EC)-funded European Network of Biosafety-Level-4 laboratories (Euronet-P4), which brings together the laboratories in Porton Down, London, Hamburg, Marburg, Solna, Lyon and Rome, seeks to increase international collaboration in the areas of high containment laboratory biosafety and viral diagnostic capability, to strengthen Europe's capacity to respond to an infectious disease emergency, and to offer assistance to countries not equipped with such costly facilities. Network partners have agreed on a common strategy to fill the gaps identified in the field of risk group-4 agents' laboratory diagnosis, namely the lack of standardization and of reference samples. The network has received a further 3-year funding, to offer assistance to external laboratories, and to start the planning of field activities.

  14. D 2 and DT Liquid-Layer Target Shots on NIF

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walters, Curtis; Alger, Ethan; Bhandarkar, Suhas

    Experiments at the National Ignition Facility (NIF) using targets containing a Deuterium-Tritium (DT) fuel layer have, until recently, required that a high-quality layer of solid deuterium-tritium (herein referred to as an "ice-layer") be formed in the capsule. The development of a process to line the inner surface of a target capsule with a foam layer of a thickness that is typical of icelayers has resulted in the ability to field targets with liquid layers wetting the foam. Successful fielding of liquid-layer targets on NIF required not only a foam lined capsule, but also changes to the capsule filling process andmore » the manner with which the inventory is maintained in the capsule. Additionally, changes to target heater power and the temperature drops across target components were required in order to achieve the desired range of shot temperatures. These changes, and the target's performance during four target shots on NIF will be discussed.« less

  15. 49 CFR 614.101 - Cross-reference to management systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... traffic monitoring for highways and public transportation facilities and equipment. ... 49 Transportation 7 2010-10-01 2010-10-01 false Cross-reference to management systems. 614.101 Section 614.101 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL TRANSIT...

  16. Comparative High Voltage Impulse Measurement

    PubMed Central

    FitzPatrick, Gerald J.; Kelley, Edward F.

    1996-01-01

    A facility has been developed for the determination of the ratio of pulse high voltage dividers over the range from 10 kV to 300 kV using comparative techniques with Kerr electro-optic voltage measurement systems and reference resistive voltage dividers. Pulse voltage ratios of test dividers can be determined with relative expanded uncertainties of 0.4 % (coverage factor k = 2 and thus a two standard deviation estimate) or less using the complementary resistive divider/Kerr cell reference systems. This paper describes the facility and specialized procedures used at NIST for the determination of test voltage divider ratios through comparative techniques. The error sources and special considerations in the construction and use of reference voltage dividers to minimize errors are discussed, and estimates of the measurement uncertainties are presented. PMID:27805083

  17. 43 CFR 3271.13 - How do I obtain approval to build pipelines and facilities connecting the well field to...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 43 Public Lands: Interior 2 2011-10-01 2011-10-01 false How do I obtain approval to build pipelines and facilities connecting the well field to utilization facilities not located on Federal lands leased for geothermal resources? 3271.13 Section 3271.13 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF LAND...

  18. 43 CFR 3271.13 - How do I obtain approval to build pipelines and facilities connecting the well field to...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 43 Public Lands: Interior 2 2013-10-01 2013-10-01 false How do I obtain approval to build pipelines and facilities connecting the well field to utilization facilities not located on Federal lands leased for geothermal resources? 3271.13 Section 3271.13 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF LAND...

  19. 43 CFR 3271.13 - How do I obtain approval to build pipelines and facilities connecting the well field to...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 43 Public Lands: Interior 2 2014-10-01 2014-10-01 false How do I obtain approval to build pipelines and facilities connecting the well field to utilization facilities not located on Federal lands leased for geothermal resources? 3271.13 Section 3271.13 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF LAND...

  20. 43 CFR 3271.13 - How do I obtain approval to build pipelines and facilities connecting the well field to...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 43 Public Lands: Interior 2 2012-10-01 2012-10-01 false How do I obtain approval to build pipelines and facilities connecting the well field to utilization facilities not located on Federal lands leased for geothermal resources? 3271.13 Section 3271.13 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF LAND...

  1. Thermal radiation transfer calculations in combustion fields using the SLW model coupled with a modified reference approach

    NASA Astrophysics Data System (ADS)

    Darbandi, Masoud; Abrar, Bagher

    2018-01-01

    The spectral-line weighted-sum-of-gray-gases (SLW) model is considered as a modern global model, which can be used in predicting the thermal radiation heat transfer within the combustion fields. The past SLW model users have mostly employed the reference approach to calculate the local values of gray gases' absorption coefficient. This classical reference approach assumes that the absorption spectra of gases at different thermodynamic conditions are scalable with the absorption spectrum of gas at a reference thermodynamic state in the domain. However, this assumption cannot be reasonable in combustion fields, where the gas temperature is very different from the reference temperature. Consequently, the results of SLW model incorporated with the classical reference approach, say the classical SLW method, are highly sensitive to the reference temperature magnitude in non-isothermal combustion fields. To lessen this sensitivity, the current work combines the SLW model with a modified reference approach, which is a particular one among the eight possible reference approach forms reported recently by Solovjov, et al. [DOI: 10.1016/j.jqsrt.2017.01.034, 2017]. The combination is called "modified SLW method". This work shows that the modified reference approach can provide more accurate total emissivity calculation than the classical reference approach if it is coupled with the SLW method. This would be particularly helpful for more accurate calculation of radiation transfer in highly non-isothermal combustion fields. To approve this, we use both the classical and modified SLW methods and calculate the radiation transfer in such fields. It is shown that the modified SLW method can almost eliminate the sensitivity of achieved results to the chosen reference temperature in treating highly non-isothermal combustion fields.

  2. Timely referral saves the lives of mothers and newborns: Midwifery led continuum of care in marginalized teagarden communities - A qualitative case study in Bangladesh.

    PubMed

    Biswas, Animesh; Anderson, Rondi; Doraiswamy, Sathyanarayanan; Abdullah, Abu Sayeed Md; Purno, Nabila; Rahman, Fazlur; Halim, Abdul

    2018-01-01

    Background: Prompt and efficient identification, referral of pregnancy related complications and emergencies are key factors to the reduction of maternal and newborn morbidity and mortality. As a response to this critical need, a midwifery led continuum of reproductive health care was introduced in five teagardens in the Sylhet division, Bangladesh during 2016. Within this intervention, professional midwives provided reproductive healthcare to pregnant teagarden women in the community.  This study evaluates the effect of the referral of pregnancy related complications. Methods: A qualitative case study design by reviewing records retrospectively was used to explore the effect of deploying midwives on referrals of pregnancy related complications from the selected teagardens to the referral health facilities in Moulvibazar district of the Sylhet division during 2016.  In depth analyses was also performed on 15 randomly selected cases to understand the facts behind the referral. Results: Out of a total population of 450 pregnant women identified by the midwives, 72 complicated mothers were referred from the five teagardens to the facilities. 76.4% of mothers were referred to conduct delivery at facilities, and 31.1% of them were referred with the complication of prolonged labour. Other major complications were pre-eclampsia (17.8%), retention of the placenta with post-partum hemorrhage (11.1%) and premature rupture of the membrane (8.9%). About 60% of complicated mothers were referred to the primary health care centre, and among them 14% of mothers were delivered by caesarean section. 94% deliveries resulted in livebirths and only 6% were stillbirths. Conclusions: This study reveals that early detection of pregnancy complications by skilled professionals and timely referral to a facility is beneficial in saving the majority of baby's as well as mother's lives in resource-poor teagardens with a considerable access barrier to health facilities.

  3. Timely referral saves the lives of mothers and newborns: Midwifery led continuum of care in marginalized teagarden communities – A qualitative case study in Bangladesh

    PubMed Central

    Biswas, Animesh; Anderson, Rondi; Doraiswamy, Sathyanarayanan; Abdullah, Abu Sayeed Md.; Purno, Nabila; Rahman, Fazlur; Halim, Abdul

    2018-01-01

    Background: Prompt and efficient identification, referral of pregnancy related complications and emergencies are key factors to the reduction of maternal and newborn morbidity and mortality. As a response to this critical need, a midwifery led continuum of reproductive health care was introduced in five teagardens in the Sylhet division, Bangladesh during 2016. Within this intervention, professional midwives provided reproductive healthcare to pregnant teagarden women in the community.  This study evaluates the effect of the referral of pregnancy related complications. Methods: A qualitative case study design by reviewing records retrospectively was used to explore the effect of deploying midwives on referrals of pregnancy related complications from the selected teagardens to the referral health facilities in Moulvibazar district of the Sylhet division during 2016.  In depth analyses was also performed on 15 randomly selected cases to understand the facts behind the referral. Results: Out of a total population of 450 pregnant women identified by the midwives, 72 complicated mothers were referred from the five teagardens to the facilities. 76.4% of mothers were referred to conduct delivery at facilities, and 31.1% of them were referred with the complication of prolonged labour. Other major complications were pre-eclampsia (17.8%), retention of the placenta with post-partum hemorrhage (11.1%) and premature rupture of the membrane (8.9%). About 60% of complicated mothers were referred to the primary health care centre, and among them 14% of mothers were delivered by caesarean section. 94% deliveries resulted in livebirths and only 6% were stillbirths. Conclusions: This study reveals that early detection of pregnancy complications by skilled professionals and timely referral to a facility is beneficial in saving the majority of baby’s as well as mother’s lives in resource-poor teagardens with a considerable access barrier to health facilities. PMID:29707205

  4. 30 CFR 585.825 - When must I assess my facilities?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Section 585.825 Mineral Resources BUREAU OF OCEAN ENERGY MANAGEMENT, DEPARTMENT OF THE INTERIOR OFFSHORE... Safety Management, Inspections, and Facility Assessments for Activities Conducted Under SAPs, COPs and... Offshore Platforms—Working Stress Design (as incorporated by reference in § 585.115). (b) You must initiate...

  5. 30 CFR 585.825 - When must I assess my facilities?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Section 585.825 Mineral Resources BUREAU OF OCEAN ENERGY MANAGEMENT, DEPARTMENT OF THE INTERIOR OFFSHORE... Safety Management, Inspections, and Facility Assessments for Activities Conducted Under SAPs, COPs and... Offshore Platforms—Working Stress Design (as incorporated by reference in § 585.115). (b) You must initiate...

  6. 30 CFR 585.825 - When must I assess my facilities?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Section 585.825 Mineral Resources BUREAU OF OCEAN ENERGY MANAGEMENT, DEPARTMENT OF THE INTERIOR OFFSHORE... Safety Management, Inspections, and Facility Assessments for Activities Conducted Under SAPs, COPs and... Offshore Platforms—Working Stress Design (as incorporated by reference in § 585.115). (b) You must initiate...

  7. 10 CFR 170.21 - Schedule of fees for production and utilization facilities, review of standard referenced design...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ..., review of standard referenced design approvals, special projects, inspections and import and export... standard referenced design approvals, special projects, inspections and import and export licenses..., approvals of facility standard reference designs, re-qualification and replacement examinations for reactor...

  8. 10 CFR 170.21 - Schedule of fees for production and utilization facilities, review of standard referenced design...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ..., review of standard referenced design approvals, special projects, inspections and import and export... standard referenced design approvals, special projects, inspections and import and export licenses..., approvals of facility standard reference designs, re-qualification and replacement examinations for reactor...

  9. 10 CFR 170.21 - Schedule of fees for production and utilization facilities, review of standard referenced design...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ..., review of standard referenced design approvals, special projects, inspections and import and export... standard referenced design approvals, special projects, inspections and import and export licenses..., approvals of facility standard reference designs, re-qualification and replacement examinations for reactor...

  10. 10 CFR 170.21 - Schedule of fees for production and utilization facilities, review of standard referenced design...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ..., review of standard referenced design approvals, special projects, inspections and import and export... standard referenced design approvals, special projects, inspections and import and export licenses..., approvals of facility standard reference designs, re-qualification and replacement examinations for reactor...

  11. Centralization vs. Decentralization: A Location Analysis Approach for Librarians

    ERIC Educational Resources Information Center

    Raffel, Jeffrey; Shishko, Robert

    1972-01-01

    An application of location theory to the question of centralized versus decentralized library facilities for a university, with relevance for special libraries is presented. The analysis provides models for a single library, for two or more libraries, or for decentralized facilities. (6 references) (Author/NH)

  12. Balancing Multiple Needs through Innovative Facility Design.

    ERIC Educational Resources Information Center

    Romano, C. Renee; Hanish, Jan

    2003-01-01

    Designing buildings that incorporate and integrate a number of departments and functions is one way that colleges and universities are balancing financial challenges and facility needs. These buildings can transform the campus, but they require planning and coordination from a carefully assembled design team. (Contains 18 references.) (Author)

  13. 14 CFR 171.263 - Localizer automatic monitor system.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... (CONTINUED) NAVIGATIONAL FACILITIES NON-FEDERAL NAVIGATION FACILITIES Interim Standard Microwave Landing... provide an automatic monitor system that transmits a warning to designated local and remote control points... centerline equivalent to more than 0.015 DDM at the ISMLS reference datum. (2) For localizers in which the...

  14. 14 CFR 171.263 - Localizer automatic monitor system.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... (CONTINUED) NAVIGATIONAL FACILITIES NON-FEDERAL NAVIGATION FACILITIES Interim Standard Microwave Landing... provide an automatic monitor system that transmits a warning to designated local and remote control points... centerline equivalent to more than 0.015 DDM at the ISMLS reference datum. (2) For localizers in which the...

  15. 14 CFR 171.263 - Localizer automatic monitor system.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... (CONTINUED) NAVIGATIONAL FACILITIES NON-FEDERAL NAVIGATION FACILITIES Interim Standard Microwave Landing... provide an automatic monitor system that transmits a warning to designated local and remote control points... centerline equivalent to more than 0.015 DDM at the ISMLS reference datum. (2) For localizers in which the...

  16. 14 CFR 171.263 - Localizer automatic monitor system.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... (CONTINUED) NAVIGATIONAL FACILITIES NON-FEDERAL NAVIGATION FACILITIES Interim Standard Microwave Landing... provide an automatic monitor system that transmits a warning to designated local and remote control points... centerline equivalent to more than 0.015 DDM at the ISMLS reference datum. (2) For localizers in which the...

  17. 14 CFR 171.263 - Localizer automatic monitor system.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... (CONTINUED) NAVIGATIONAL FACILITIES NON-FEDERAL NAVIGATION FACILITIES Interim Standard Microwave Landing... provide an automatic monitor system that transmits a warning to designated local and remote control points... centerline equivalent to more than 0.015 DDM at the ISMLS reference datum. (2) For localizers in which the...

  18. Operation and Maintenance of Wastewater Treatment Facilities.

    ERIC Educational Resources Information Center

    Drury, Douglas D.

    1978-01-01

    Presents the 1978 literature review of wastewater treatment: (1) operators, training, and certification; (2) solutions to operating problems; (3) collection systems; (4) operations manuals; (5) wastewater treatment facility case histories; (5) land application; and (6) treatment of industrial wastes. A list of 36 references is also presented. (HM)

  19. Measurement of momentum transfer due to adhesive forces: on-ground testing of in-space body injection into geodesic motion.

    PubMed

    Bortoluzzi, D; Benedetti, M; Baglivo, L; De Cecco, M; Vitale, S

    2011-12-01

    In the frame of many scientific space missions, a massive free-falling object is required to mark a geodesic trajectory, i.e., to follow inside a spacecraft an orbit that is determined only by the planetary gravity field. The achievement of high-purity geodesic trajectories sets tight design constraints on the reference sensor that hosts and controls the reference body. Among these, a mechanism may be required to cage the reference body during the spacecraft launch and to inject it into the geodesic trajectory once on-orbit. The separation of the body from the injection mechanism must be realized against the action of adhesion forces, and in the worst case this is performed dynamically, relying on the body's inertia through a quick retraction of the holding finger(s). Unfortunately, this manoeuvre may not avoid transferring some momentum to the body, which may affect or even jeopardize the subsequent spacecraft control if the residual velocity is too large. The transferred momentum measurement facility (TMMF) was developed to reproduce representative conditions of the in-flight dynamic injection and to measure the transferred momentum to the released test mass. In this paper, we describe the design and development of the TMMF together with the achieved measurement performance.

  20. Bridgman Growth of Germanium

    NASA Technical Reports Server (NTRS)

    Szofran, F. R.; Volz, M. P.; Cobb, S. D.; Motakef, S.

    1997-01-01

    The high-magnetic-field crystal growth facility at the Marshall Space Flight Center will be briefly described. This facility has been used to grow bulk germanium by the Bridgman technique in magnetic fields up to 5 Tesla. The results of investigations of ampoule material on the interface shape and thermal field applied to the melt on stability against convection will be discussed.

  1. 1989 Intercomparison of radon progeny measurement methods and equipment in North America

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scofield, P.; George, A.; Tu, Keng.

    1990-03-01

    At the 1989 {sup 222}Rn progeny intercomparison held at the Environmental Measurements Laboratory (EML), July 10--14, 1989, grab sampling and integrating/continuous {sup 222}Rn progeny methods were evaluated. Sixteen facilities participated in this intercomparison. Twelve facilities used {sup 222}Rn progeny grab sampling methods, and nine facilities used integrating/continuous instruments. Eighty-eight percent of the participants reported grab sample {sup 222}Rn progeny concentrations that were within 20% of the EML reference values. Good agreement between participant and EML grab-sample potential alpha energy concentrations (PAECs) was observed; 92% of the participants had PAECs within 20% of the EML values. For the integrating/continuous PAEC valuesmore » determined with integrating/continuous monitors, 89% of the participants were within 20% of the EML reference values. 9 refs., 3 figs., 4 tabs.« less

  2. [Scientific research in public health institutions of the City of Buenos Aires].

    PubMed

    Ferrero, Fernando; Ossorio, María Fabiana; Eiguch, Kumiko

    2013-01-01

    Hospitals with academic activities offer better services to their patients. The Government of Buenos Aires City (GBAC) has an important network of health facilities, but there is little information regarding their academic activities. Our aim was to estimate the proportion of articles included in MEDLINE originated in GBAC hospitals, to evaluate their contribution regarding the whole country (Argentina), and to describe some characteristics of these papers. It is a cross-sectional study based on a MEDLINE search, using the name of each of the 33 GBAC hospitals in the "affiliation" field. Among 22 million references, 1781 belonged to GBAC hospitals (4.4% of all references from Argentina); 66.5% were in English, 83.7% were related to humans, 30.1% were from the last 5 years, 8.3% included high level scientific evidence research (meta-analysis or randomized controlled trials), and 31.1% included research in children. Regarding the rest of the references from Argentina, those from GBAC hospitals included less papers in English (66.5% vs. 90.0%; OR: 0.22; p < 0.0001), less recent papers (30.1% vs. 34.6%; OR: 0.81; p < 0.0001), more research in humans (83.7% vs. 37.3%; OR: 8.65; p < 0.0001), more randomized controlled trials (8.0% vs. 2.8%; OR: 2,9; p < 0.0001), and more research in children (31.1% vs. 9.2%; OR: 4.44; p < 0.0001). GBAC hospitals contributed with 4.4% of references attributed to Argentina in MEDLINE. References from GBAC hospitals were less recent, and included more randomized controlled trials and research in children.

  3. Savannah River Site nuclear materials management plan FY 2017-2031

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Magoulas, V.

    The purpose of the Nuclear Materials Management Plan (herein referred to as “this Plan”) is to integrate and document the activities required to disposition the legacy and/or surplus Enriched Uranium (EU) and Plutonium (Pu) and other nuclear materials already stored or anticipated to be received by facilities at the Department of Energy (DOE) Savannah River Site (SRS) as well as the activities to support the DOE Tritium mission. It establishes a planning basis for EU and Pu processing operations in Environmental Management Operations (EMO) facilities through the end of their program missions and for the tritium through the National Nuclearmore » Security Administration (NNSA) Defense Programs (DP) facilities. Its development is a joint effort among the Department of Energy - Savannah River (DOE-SR), DOE – Environmental Management (EM), NNSA Office of Material Management and Minimization (M3), NNSA Savannah River Field Office (SRFO), and the Management and Operations (M&O) contractor, Savannah River Nuclear Solutions, LLC (SRNS). Life-cycle program planning for Nuclear Materials Stabilization and Disposition and the Tritium Enterprise may use this Plan as a basis for the development of the nuclear materials disposition scope and schedule. This Plan assumes full funding to accomplish the required project and operations activities. It is recognized that some aspects of this Plan are pre decisional with regard to National Environmental Policy Act (NEPA); in such cases new NEPA actions will be required.« less

  4. Thermal/structural modeling of a large scale in situ overtest experiment for defense high level waste at the Waste Isolation Pilot Plant Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morgan, H.S.; Stone, C.M.; Krieg, R.D.

    Several large scale in situ experiments in bedded salt formations are currently underway at the Waste Isolation Pilot Plant (WIPP) near Carlsbad, New Mexico, USA. In these experiments, the thermal and creep responses of salt around several different underground room configurations are being measured. Data from the tests are to be compared to thermal and structural responses predicted in pretest reference calculations. The purpose of these comparisons is to evaluate computational models developed from laboratory data prior to fielding of the in situ experiments. In this paper, the computational models used in the pretest reference calculation for one of themore » large scale tests, The Overtest for Defense High Level Waste, are described; and the pretest computed thermal and structural responses are compared to early data from the experiment. The comparisons indicate that computed and measured temperatures for the test agree to within ten percent but that measured deformation rates are between two and three times greater than corresponsing computed rates. 10 figs., 3 tabs.« less

  5. NASA thesaurus. Volume 3: Definitions

    NASA Technical Reports Server (NTRS)

    1988-01-01

    Publication of NASA Thesaurus definitions began with Supplement 1 to the 1985 NASA Thesaurus. The definitions given here represent the complete file of over 3,200 definitions, complimented by nearly 1,000 use references. Definitions of more common or general scientific terms are given a NASA slant if one exists. Certain terms are not defined as a matter of policy: common names, chemical elements, specific models of computers, and nontechnical terms. The NASA Thesaurus predates by a number of years the systematic effort to define terms, therefore not all Thesaurus terms have been defined. Nevertheless, definitions of older terms are continually being added. The following data are provided for each entry: term in uppercase/lowercase form, definition, source, and year the term (not the definition) was added to the NASA Thesaurus. The NASA History Office is the authority for capitalization in satellite and spacecraft names. Definitions with no source given were constructed by lexicographers at the NASA Scientific and Technical Information (STI) Facility who rely on the following sources for their information: experts in the field, literature searches from the NASA STI database, and specialized references.

  6. 30 CFR 250.1628 - Design, installation, and operation of production systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Systems (as incorporated by reference in § 250.198); (3) Electrical system information including a plan of... Practice for Classification of Locations for Electrical Installations at Petroleum Facilities Classified as... for Electrical Installations at Petroleum Facilities Classified as Class I, Zone 0, Zone 1, and Zone 2...

  7. 30 CFR 250.1628 - Design, installation, and operation of production systems.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Systems (as incorporated by reference in § 250.198); (3) Electrical system information including a plan of... Practice for Classification of Locations for Electrical Installations at Petroleum Facilities Classified as... for Electrical Installations at Petroleum Facilities Classified as Class I, Zone 0, Zone 1, and Zone 2...

  8. 30 CFR 250.1628 - Design, installation, and operation of production systems.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Systems (as incorporated by reference in § 250.198); (3) Electrical system information including a plan of... Practice for Classification of Locations for Electrical Installations at Petroleum Facilities Classified as... for Electrical Installations at Petroleum Facilities Classified as Class I, Zone 0, Zone 1, and Zone 2...

  9. 77 FR 30888 - Heating, Cooling, and Lighting Standards for Bureau-Funded Dormitory Facilities

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-24

    ...As required by the No Child Left Behind Act of 2001, the Secretary of the Interior has developed regulations using negotiated rulemaking that address heating, cooling, and lighting standards for Bureau-funded dormitory facilities. These regulations also make a technical change to remove an obsolete reference.

  10. Construction Grants for Educational Facilities, Fiscal Years 1965-77. Health Manpower References.

    ERIC Educational Resources Information Center

    Berman, Bella U.; Rosenthal, Samuel

    This publication provides information on construction assistance awarded to schools of medicine, osteopathic medicine, dentistry, optometry, pharmacy, podiatric medicine, veterinary medicine, public health, and nursing. In addition it provides data on grants awarded to schools of allied health, medical libraries, and health research facilities.…

  11. 20 CFR 655.310 - Attestations.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... attest that it shall refer H-1A nurses only to facilities that, with the exception of private households...) Where should attestations be submitted? Attestations shall be submitted, by U.S. mail or private carrier... this section; or (B) If the facility is a worksite (other than a private household which itself does...

  12. The National Bio- and Agro-Defense Facility: Issues for Congress

    DTIC Science & Technology

    2007-10-04

    change. The DHS predicts that the facility will focus on foot and mouth disease (FMD), classical swine fever , African swine fever , Rift Valley fever ...Preparedness, by Jim Monke. 2 Examples include influenza, plague, West Nile Virus, and Rift Valley Fever . 3 These diseases are sometimes referred to

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brink, J.

    Crude oil (c. 10,700 BOPD) was produced through temporary topside facilities in the Rolf Field offshore Denmark from January 7th to September 17th, 1986. These simple, unmanned and remote controlled facilities were a low cost solution to a problem caused by delays of the permanent topside facilities. Project execution time was two months from start of conceptual design until start-up of oil production. Installation works were performed from a jack-up drilling rig - in part simultaneously with drilling operations. Materials and equipment installed were obtained with very short delivery times. The facilties which were certified by a Certification Society andmore » approved by the Danish Authoritites included all necessary safety features. Total costs for the facilities amounted to c. 1 million US$ (excl. rig time for installation). Due to simplicity high reliability of the production system was obtained. Availability of the facilities for the entire period from start-up was 99.6 percent. The facilities were manned 3.2 percent of the total operating time mainly due to wireline work for reservoir monitoring. It is considered that the experience with the concept applied for the early production from the Rolf Field could form the basis for more simple and cost effective topside facilities for minor offshore fields.« less

  14. 21 CFR 814.3 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    .... (d) Master file means a reference source that a person submits to FDA. A master file may contain detailed information on a specific manufacturing facility, process, methodology, or component used in the... for a class III medical device, including all information submitted with or incorporated by reference...

  15. 30 CFR 285.115 - Documents incorporated by reference.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Documents incorporated by reference. 285.115 Section 285.115 Mineral Resources MINERALS MANAGEMENT SERVICE, DEPARTMENT OF THE INTERIOR OFFSHORE RENEWABLE ENERGY ALTERNATE USES OF EXISTING FACILITIES ON THE OUTER CONTINENTAL SHELF General Provisions...

  16. Library Information Resource Book For Staff.

    ERIC Educational Resources Information Center

    Potts, Ken; And Others

    This guide is the Northern Illinois University (NIU) Libraries' quick reference tool for providing information about its collections, facilities, and services. The articles are arranged in an alphabetic, dictionary format with numerous cross-references, and highlight information on the following: administrative offices; company annual reports;…

  17. Conceptual design of the MHD Engineering Test Facility

    NASA Technical Reports Server (NTRS)

    Bents, D. J.; Bercaw, R. W.; Burkhart, J. A.; Mroz, T. S.; Rigo, H. S.; Pearson, C. V.; Warinner, D. K.; Hatch, A. M.; Borden, M.; Giza, D. A.

    1981-01-01

    The reference conceptual design of the MHD engineering test facility, a prototype 200 MWe coal-fired electric generating plant designed to demonstrate the commerical feasibility of open cycle MHD is summarized. Main elements of the design are identified and explained, and the rationale behind them is reviewed. Major systems and plant facilities are listed and discussed. Construction cost and schedule estimates are included and the engineering issues that should be reexamined are identified.

  18. Conventional Gymnasium vs. Geodesic Field House. A Comparative Study of High School Physical Education and Assembly Facilities.

    ERIC Educational Resources Information Center

    Educational Facilities Labs., Inc., New York, NY.

    A description is presented of the design features of a high school's geodesic dome field house. Following consideration of various design features and criteria for the physical education facility, a comprehensive analysis is given of comparative costs of a geodesic dome field house and conventional gymnasium. On the basis of the study it would…

  19. Pricing and availability of some essential child specific medicines in Odisha

    PubMed Central

    Swain, Trupti Rekha; Rath, Bandana; Dehury, Suhasini; Tarai, Anjali; Das, Priti; Samal, Rajashree; Samal, Satyajit; Nayak, Harshavardhan

    2015-01-01

    Objectives: Continuous availability of affordable medicines in appropriate formulations is essential to reduce morbidity and mortality in children. Odisha an eastern Indian state records very high mortality of children. The study aims at documenting the availability and prices paid for purchasing essential child-specific medicines. Materials and Methods: The survey of 34 essential medicines was conducted in six randomly selected districts of Odisha. Data were collected from medicine outlets of the public, private, and other sector (Nongovernmental Organization [NGO]/mission sectors) of six randomly selected districts, using WHO/Health Action International medicine price collection methodology. For each medicine surveyed, data were collected on the highest and lowest-priced formulations available in each facility. Results: Both public sector and other sector health facilities procure only one brand of medicines, mean percentage availability of medicines being 17% and 21.8%, respectively. In the private sector, the mean percentage availability of the high and lowest-priced medicines for a particular drug product was 10.8% and 38.5%, respectively. The public sector procurement price is 48% lower than international reference prices. In the private sector, high-priced, and low-priced products are sold at 1.83 and 1.46 times the international reference price, respectively. Substantial price variation was observed for some medicines across individual outlets. Medicines were found to cost 2.08 times their international reference price in NGO/mission sector facilities. Conclusions: The availability of children's medicines in public sector facilities of Odisha state is poor. Medicines for children cost relatively high in both private and NGO sectors compared to the international reference price. The availability medicines should be improved on an urgent basis to improve access of medicines for children of Odisha. PMID:26600637

  20. Pricing and availability of some essential child specific medicines in Odisha.

    PubMed

    Swain, Trupti Rekha; Rath, Bandana; Dehury, Suhasini; Tarai, Anjali; Das, Priti; Samal, Rajashree; Samal, Satyajit; Nayak, Harshavardhan

    2015-01-01

    Continuous availability of affordable medicines in appropriate formulations is essential to reduce morbidity and mortality in children. Odisha an eastern Indian state records very high mortality of children. The study aims at documenting the availability and prices paid for purchasing essential child-specific medicines. The survey of 34 essential medicines was conducted in six randomly selected districts of Odisha. Data were collected from medicine outlets of the public, private, and other sector (Nongovernmental Organization [NGO]/mission sectors) of six randomly selected districts, using WHO/Health Action International medicine price collection methodology. For each medicine surveyed, data were collected on the highest and lowest-priced formulations available in each facility. Both public sector and other sector health facilities procure only one brand of medicines, mean percentage availability of medicines being 17% and 21.8%, respectively. In the private sector, the mean percentage availability of the high and lowest-priced medicines for a particular drug product was 10.8% and 38.5%, respectively. The public sector procurement price is 48% lower than international reference prices. In the private sector, high-priced, and low-priced products are sold at 1.83 and 1.46 times the international reference price, respectively. Substantial price variation was observed for some medicines across individual outlets. Medicines were found to cost 2.08 times their international reference price in NGO/mission sector facilities. The availability of children's medicines in public sector facilities of Odisha state is poor. Medicines for children cost relatively high in both private and NGO sectors compared to the international reference price. The availability medicines should be improved on an urgent basis to improve access of medicines for children of Odisha.

  1. First report on a European round robin for slope measuring profilers

    NASA Astrophysics Data System (ADS)

    Rommeveaux, Amparo; Thomasset, Muriel; Cocco, Daniele; Siewert, Frank

    2005-08-01

    In the framework of the European COoperation in the field of Scientific and Technical research action on "X-ray and Neutron Optic" (COST P7) and following the decision announced in the last International Workshop on Metrology for X-ray and neutron optic (Grenoble, April 2004), the metrology facilities of four European synchrotrons, Bessy, Elettra, ESRF and Soleil, have decided and started a program of instrument inter-comparison. Other synchrotrons are joining us and further interested Institutions are invited to participate in this open measurement comparison. The metrology instruments involved are different kinds of direct slope measurement devices, like the well known Long Trace Profiler (in house made or modified) and the Bessy N.O.M.. The Round Robin was started with 2 flat and 2 spherical mirrors (three made of Zerodur and one of fused silica) made available by Bessy and Elettra. A short radius of curvature spherical mirror of Silicon from SOLEIL was later added. First results show a very close match between the measurements of all facilities provided that the same procedures are followed. In particular, a special attention has to be given to the way of supporting the reference objects, as it will be illustrated by some examples. Another important issue is the characterization of the systematic errors of the different instruments and how they can be reduced or eliminated. The paper expects to open a discussion on the performances of different commercial and custom made or modified profilometers, and over standard procedures for calibration testing, including the definition of standard reference surfaces.

  2. A mapping closure for turbulent scalar mixing using a time-evolving reference field

    NASA Technical Reports Server (NTRS)

    Girimaji, Sharath S.

    1992-01-01

    A general mapping-closure approach for modeling scalar mixing in homogeneous turbulence is developed. This approach is different from the previous methods in that the reference field also evolves according to the same equations as the physical scalar field. The use of a time-evolving Gaussian reference field results in a model that is similar to the mapping closure model of Pope (1991), which is based on the methodology of Chen et al. (1989). Both models yield identical relationships between the scalar variance and higher-order moments, which are in good agreement with heat conduction simulation data and can be consistent with any type of epsilon(phi) evolution. The present methodology can be extended to any reference field whose behavior is known. The possibility of a beta-pdf reference field is explored. The shortcomings of the mapping closure methods are discussed, and the limit at which the mapping becomes invalid is identified.

  3. Current state of the art in small mass and force metrology within the International System of Units

    NASA Astrophysics Data System (ADS)

    Shaw, Gordon A.

    2018-07-01

    This review article summarizes new scientific trends in research for metrology of small mass (1 mg and lower) and small force (10 micronewtons and lower). After a brief introduction to the field, this paper provides an overview of recent developments in methods that demonstrate traceability to the International System of Units (SI) with emphasis on the implications of redefining the kilogram in terms of Planck’s constant. Specific research applications include new metrology facilities, calibration of small mass and force references such as milligram to submilligram masses or atomic force microscope (AFM) cantilevers, and laser power measurement using radiation pressure forces. Also discussed are recent scientific developments that may impact the field moving forward in the study of ultrasmall forces present in trapped and cooled quantum mechanical systems, resonant micro- and nanomechanical mass sensors, and other areas that are potentially well suited for SI metrology. The work reviewed is not intended as a comprehensive review of all research in which small forces are measured, but rather as an overview of a field in which the accurate measurement of small mass and force with quantified uncertainty is the primary goal.

  4. Novel reference radiation fields for pulsed photon radiation installed at PTB.

    PubMed

    Klammer, J; Roth, J; Hupe, O

    2012-09-01

    Currently, ∼70 % of the occupationally exposed persons in Germany are working in pulsed radiation fields, mainly in the medical sector. It has been known for a few years that active electronic dosemeters exhibit considerable deficits or can even fail completely in pulsed fields. Type test requirements for dosemeters exist only for continuous radiation. Owing to the need of a reference field for pulsed photon radiation and accordingly to the upcoming type test requirements for dosemeters in pulsed radiation, the Physikalisch-Technische Bundesanstalt has developed a novel X-ray reference field for pulsed photon radiation in cooperation with a manufacturer. This reference field, geared to the main applications in the field of medicine, has been well characterised and is now available for research and type testing of dosemeters in pulsed photon radiation.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Owen, P.T.; Knox, N.P.; Fielden, J.M.

    This bibliography of 657 references with abstracts on the subject of nuclear facility decommissioning, uranium mill tailings management, and site remedial actions is the fourth in a series of annual reports prepared for the US Department of Energy, Division of Remedial Action Projects. Foreign as well as domestic documents of all types - technical reports, progress reports, journal articles, conference papers, symposium proceedings, theses, books, patents, legislation, and research project descriptions - have been references in this publication. The bibliography contains scientific (basic research as well as applied technology), economic, regulatory, and legal literature pertinent to the US Department ofmore » Energy's Remedial Action Program. Major chapters are: (1) Surplus Facilities Management Program; (2) Nuclear Facilities Decommissioning; (3) Formerly Utilized Sites Remedial Action Program; (4) Uranium Mill Tailings Remedial Action Program; (5) Grand Junction Remedial Action Program; and (6) Uranium Mill Tailings Management. Chapter sections for chapters 1 and 2 include: Design, Planning, and Regulations; Site Surveys; Decontamination Studies; Dismantlement and Demolition; Land Decontamination and Reclamation; Waste Disposal; and General studies. The references within each chapter or section are arranged alphabetically by leading author. References having no individual author are arranged by corporate author, or by title. Indexes are provided for the categories of author, corporate affiliation, title, publication description, geographic location, and keywords. Appendix A lists 264 bibliographic references to literature identified during this reporting period but not abstracted due to time constraints. Title and publication description indexes are given for this appendix. Appendix B defines frequently used acronyms, and Appendix C lists the recipients of this report according to their corporate affiliation.« less

  6. 40 CFR 53.52 - Leak check test.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... MONITORING REFERENCE AND EQUIVALENT METHODS Procedures for Testing Physical (Design) and Performance Characteristics of Reference Methods and Class I and Class II Equivalent Methods for PM 2.5 or PM 10-2.5 § 53.52... to include the facility, including components, instruments, operator controls, a written procedure...

  7. Discriminative facility and its role in the perceived quality of interactional experiences.

    PubMed

    Cheng, C; Chiu, C Y; Hong, Y Y; Cheung, J S

    2001-10-01

    Discriminative facility refers to an individual's sensitivity to subtle cues about the psychological meaning of a situation. This research aimed at examining (a) the conceptual distinctiveness of discriminative facility, (b) the situation-appropriate aspect of this construct, and (c) the relationship between discriminative facility and interpersonal experiences. Discriminative facility was assessed by a new measure of situation-appropriate behaviors across a variety of novel stressful situations. Results from study 1 showed that discriminative facility had weak positive relationships with cognitive complexity and nonsignificant relationships with self-monitoring and social desirability, indicating that discriminative facility is a unique construct. Results from Study 2 revealed that higher levels of discriminative facility were associated with higher levels of perceived social support and a greater number of pleasant interpersonal events experienced, thus providing support for the theoretical proposition that discriminative facility is an aspect of social intelligence.

  8. VIEW TO NORTHWEST, SHOWING FACILITY NO. 525 AND HOSPITAL (FACILITY ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW TO NORTHWEST, SHOWING FACILITY NO. 525 AND HOSPITAL (FACILITY No. 515) BEYOND. See CA-2398-CP-8 for detail of the stairway in the distance - Hamilton Field, Amphitheater, North Oakland Drive near East Hospital Drive, Novato, Marin County, CA

  9. 40 CFR 160.45 - Test system supply facilities.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... aquatic plants. (2) Facilities for plant growth, including, but not limited to greenhouses, growth chambers, light banks, and fields. (c) When appropriate, facilities for aquatic animal tests shall be... preserved by appropriate means. (b) When appropriate, plant supply facilities shall be provided. As...

  10. Nuclear quadrupole resonance studies project. [spectrometer design and spectrum analysis

    NASA Technical Reports Server (NTRS)

    Murty, A. N.

    1978-01-01

    The participation of undergraduates in nuclear quadrupole resonance research at Grambling University was made possible by NASA grants. Expanded laboratory capabilities include (1) facilities for high and low temperature generation and measurement; (2) facilities for radio frequency generation and measurement with the modern spectrum analyzers, precision frequency counters and standard signal generators; (3) vacuum and glass blowing facilities; and (4) miscellaneous electronic and machine shop facilities. Experiments carried out over a five year period are described and their results analyzed. Theoretical studies on solid state crystalline electrostatic fields, field gradients, and antishielding factors are included.

  11. Field Notes

    ERIC Educational Resources Information Center

    Parrone, Edward G.; Montalto, Michael P.

    2008-01-01

    The importance of athletic fields has increased in today's society because of the popularity of sporting events. As a result, education administrators face challenges when dealing with their athletic facilities. Decisionmakers constantly are being second-guessed in regard to outdated, overused facilities and lack of budget. In this article, the…

  12. U.S. EPA High-Field NMR Facility with Remote Accessibility

    EPA Science Inventory

    EPA’s High-Field Nuclear Magnetic Resonance Research Facility housed in Athens, GA has two Varian 600 MHz NMR spectrometers used for conducting sophisticated experiments in environmental science. Off-site users can ship their samples and perform their NMR experiments remotely fr...

  13. Benchmark studies of induced radioactivity produced in LHC materials, Part II: Remanent dose rates.

    PubMed

    Brugger, M; Khater, H; Mayer, S; Prinz, A; Roesler, S; Ulrici, L; Vincke, H

    2005-01-01

    A new method to estimate remanent dose rates, to be used with the Monte Carlo code FLUKA, was benchmarked against measurements from an experiment that was performed at the CERN-EU high-energy reference field facility. An extensive collection of samples of different materials were placed downstream of, and laterally to, a copper target, intercepting a positively charged mixed hadron beam with a momentum of 120 GeV c(-1). Emphasis was put on the reduction of uncertainties by taking measures such as careful monitoring of the irradiation parameters, using different instruments to measure dose rates, adopting detailed elemental analyses of the irradiated materials and making detailed simulations of the irradiation experiment. The measured and calculated dose rates are in good agreement.

  14. Visibility and Visual Characteristics of the Ivanpah Solar Electric Generating System Power Tower Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sullivan, Robert; Abplanalp, Jennifer M.

    2015-03-01

    This report presents the results of a study conducted to document the visibility and visual characteristics of the Ivanpah Solar Electric Generating System (ISEGS), a utility-scale solar power tower facility located on land administered by the U.S. Department of the Interior Bureau of Land Management in southern California. Study activities consisted of field observations of the ISEGS facility and comparison of the observations made in the field with the visual contrast assessments and visual simulations in the ISEGS Final Environmental Impact Statement (Final EIS) and supporting documents created prior to ISEGS construction. Field observations of ISEGS were made from 19more » locations within 35 mi (56 km) of the facility in the course of one week in September 2014. The study results established that reflected sunlight from the receivers was the primary source of visual contrast from the operating ISEGS facility. The ISEGS facility was found to be a major source of visual contrast for all observations up to 20 mi (32 km), and was easily visible at 35 mi. Glare from individual heliostats was frequently visible, and often brighter than the reflected light from the receivers. Heliostat glare caused discomfort for one or more viewers at distances up to 20 mi. The ISEGS power blocks were brightly lit at night, and were conspicuous at the observation distance of approximately 6 mi (10 km). The facility is substantially brighter and is seen more clearly in the field than in photographs of the facility or in the prepared simulations, which were based on photographs. The simulations of the ISEGS facility in the Final EIS, which were evaluated as part of this study, sometimes lacked spatial accuracy and realism. The evaluated simulations generally under-represented the actual visual contrast from the project, and some of the contrast ratings in the Final EIS predicted substantially lower levels of visual contrast than were actually observed for the operating facility.« less

  15. Status of Activities to Implement a Sustainable System of MC&A Equipment and Methodological Support at Rosatom Facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J.D. Sanders

    Under the U.S.-Russian Material Protection, Control and Accounting (MPC&A) Program, the Material Control and Accounting Measurements (MCAM) Project has supported a joint U.S.-Russian effort to coordinate improvements of the Russian MC&A measurement system. These efforts have resulted in the development of a MC&A Equipment and Methodological Support (MEMS) Strategic Plan (SP), developed by the Russian MEM Working Group. The MEMS SP covers implementation of MC&A measurement equipment, as well as the development, attestation and implementation of measurement methodologies and reference materials at the facility and industry levels. This paper provides an overview of the activities conducted under the MEMS SP,more » as well as a status on current efforts to develop reference materials, implement destructive and nondestructive assay measurement methodologies, and implement sample exchange, scrap and holdup measurement programs across Russian nuclear facilities.« less

  16. 38 CFR 17.63 - Approval of community residential care facilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... patients in the event of fire or other emergency. Incorporation by reference of these materials was..., exclusive of closet space, at least 100 square feet for a single-resident room, or 80 square feet for each... independent living situation. (i) Records. (1) The facility must maintain records on each resident in a secure...

  17. 36 CFR 1234.12 - What are the fire safety requirements that apply to records storage facilities?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... that have been incorporated to minimize loss. The report should make specific reference to appropriate.... Retrofitting may require modifications to the piping system to ensure that adequate water capacity and pressure... storage facilities, boiler rooms or rooms containing equipment operating with a fuel supply (such as...

  18. BIBLIO: A Computer System Designed to Support the Near-Library User Model of Information Retrieval.

    ERIC Educational Resources Information Center

    Belew, Richard K.; Holland, Maurita Peterson

    1988-01-01

    Description of the development of the Information Exchange Facility, a prototype microcomputer-based personal bibliographic facility, covers software selection, user selection, overview of the system, and evaluation. The plan for an integrated system, BIBLIO, and the future role of libraries are discussed. (eight references) (MES)

  19. Process Control Manual for Aerobic Biological Wastewater Treatment Facilities.

    ERIC Educational Resources Information Center

    Environmental Protection Agency, Washington, DC. Office of Water Programs.

    This Environmental Protection Agency (EPA) publication is an operations manual for activated sludge and trickling filter wastewater treatment facilities. The stated purpose of the manual is to provide an on-the-job reference for operators of these two types of treatment plants. The overall objective of the manual is to aid the operator in…

  20. Sustainable Design Guidelines for the Construction of New Facilities and the Renovation of Existing Structures.

    ERIC Educational Resources Information Center

    Dorsey, Judy; L'Esperance, Clare

    This guide summarizes research conducted at Colorado's Poudre School District (PSD) to develop guidelines for the desired performance outcomes from employing sustainable educational facility design, and it suggests approaches for attaining them. The guide also provides case studies and references to further investigate opportunities on specific…

  1. Facilities Data System Manual.

    ERIC Educational Resources Information Center

    Acridge, Charles W.; Ford, Tim M.

    The purposes of this manual are to set forth the scope and procedures for the maintenance and operation of the University of California facilities Data System (FDX) and to serve as a reference document for users of the system. FDX is an information system providing planning and management data about the existing physical plant. That is, it…

  2. 40 CFR 59.698 - May EPA enter my facilities for inspections?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... inspections? 59.698 Section 59.698 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Other Reference Information § 59.698 May EPA enter my facilities for inspections? (a) We may inspect... activities it describes. (c) We may seek a warrant or court order authorizing an inspection described in this...

  3. International Geomagnetic Reference Field: the third generation.

    USGS Publications Warehouse

    Peddie, N.W.

    1982-01-01

    In August 1981 the International Association of Geomagnetism and Aeronomy revised the International Geomagnetic Reference Field (IGRF). It is the second revision since the inception of the IGRF in 1968. The revision extends the earlier series of IGRF models from 1980 to 1985, introduces a new series of definitive models for 1965-1976, and defines a provisional reference field for 1975- 1980. The revision consists of: 1) a model of the main geomagnetic field at 1980.0, not continuous with the earlier series of IGRF models together with a forecast model of the secular variation of the main field during 1980-1985; 2) definitive models of the main field at 1965.0, 1970.0, and 1975.0, with linear interpolation of the model coefficients specified for intervening dates; and 3) a provisional reference field for 1975-1980, defined as the linear interpolation of the 1975 and 1980 main-field models.-from Author

  4. 32 CFR 728.12 - Extent of care.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... care. (ii) Occupational health services as defined in § 728.2(z). (iii) Necessary prosthetic devices... USPHS or NOAA, the resulting civilian health care costs will be paid by the referring facility. (3) The... referring MTF is not organized nor authorized to provide needed health care (see part 732 of this chapter...

  5. 32 CFR 728.12 - Extent of care.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... care. (ii) Occupational health services as defined in § 728.2(z). (iii) Necessary prosthetic devices... USPHS or NOAA, the resulting civilian health care costs will be paid by the referring facility. (3) The... referring MTF is not organized nor authorized to provide needed health care (see part 732 of this chapter...

  6. 24 CFR 241.251 - Cross-reference.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... SUPPLEMENTARY FINANCING FOR INSURED PROJECT MORTGAGES Contract Rights and Obligations § 241.251 Cross-reference. (a) Projects with a HUD-insured or HUD-held mortgage. All of the provisions of subpart B, part 207 of... force and effect to multifamily project and group practice facility mortgages insured under section 241...

  7. 26 CFR 49.4264(d)-1 - Cross reference.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 16 2010-04-01 2010-04-01 true Cross reference. 49.4264(d)-1 Section 49.4264(d)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) MISCELLANEOUS EXCISE TAXES FACILITIES AND SERVICES EXCISE TAXES Transportation of Persons § 49.4264(d)-1 Cross...

  8. SUPERFUND TREATABILITY CLEARINGHOUSE: BDAT INCINERATION OF CERCLA SARMS AT THE JOHN ZINK COMPANY TEST FACILITY (FINAL PROJECT REPORT)

    EPA Science Inventory

    This report presents the results of a treatability study of rotary kiln incineration of a synthetic "Superfund soil" bearing a wide range of chemical contaminants typically occurring at Superfund sites. This surrogate soil is referred to as a synthetic analytical reference ...

  9. Theatre and Cinema Architecture: A Guide to Information Sources.

    ERIC Educational Resources Information Center

    Stoddard, Richard

    This annotated bibliography cites works related to theatres, movie houses, opera houses, and dance facilities. It is divided into three parts: general references, theatre architecture, and cinema architecture. The part on general references includes bibliographies and periodicals. The second and main part of the guide, on theatre architecture,…

  10. 77 FR 63343 - Biweekly Notice: Applications and Amendments to Facility Operating Licenses and Combined Licenses...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-16

    ... PWR [Pressurized-Water Reactor] Steam Generator Tubes'' (Reference 32) and [Nuclear Energy Institute... maintains the required structural margins of the SG tubes for both normal and accident conditions. Nuclear Energy Institute 97-06, ``Steam Generator Program Guidelines'' (Reference 8), and NRC Regulatory Guide 1...

  11. 40 CFR 53.52 - Leak check test.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... MONITORING REFERENCE AND EQUIVALENT METHODS Procedures for Testing Physical (Design) and Performance Characteristics of Reference Methods and Class I and Class II Equivalent Methods for PM2.5 or PM10â2.5 § 53.52... to include the facility, including components, instruments, operator controls, a written procedure...

  12. 40 CFR 53.52 - Leak check test.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... MONITORING REFERENCE AND EQUIVALENT METHODS Procedures for Testing Physical (Design) and Performance Characteristics of Reference Methods and Class I and Class II Equivalent Methods for PM2.5 or PM10â2.5 § 53.52... to include the facility, including components, instruments, operator controls, a written procedure...

  13. 40 CFR 53.52 - Leak check test.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... MONITORING REFERENCE AND EQUIVALENT METHODS Procedures for Testing Physical (Design) and Performance Characteristics of Reference Methods and Class I and Class II Equivalent Methods for PM2.5 or PM10â2.5 § 53.52... to include the facility, including components, instruments, operator controls, a written procedure...

  14. Safety Factors in Educational Facilities. An Annotated Reference List.

    ERIC Educational Resources Information Center

    Wakefield, Howard E.

    Abstracts and descriptor terms are presented for 26 selected references with safety orientation. Included in addition to several general planning handbooks are topics related to--(1) stairways, (2) air structures, (3) site planning, (4) lighting, (5) bidding practice, (6) physically handicapped, (7) laboratory design, (8) mobile classrooms, (9)…

  15. Low-frequency RF Coupling To Unconventional (Fat Unbalanced) Dipoles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ong, M M; Brown, C G; Perkins, M P

    2010-12-07

    The report explains radio frequency (RF) coupling to unconventional dipole antennas. Normal dipoles have thin equal length arms that operate at maximum efficiency around resonance frequencies. In some applications like high-explosive (HE) safety analysis, structures similar to dipoles with ''fat'' unequal length arms must be evaluated for indirect-lightning effects. An example is shown where a metal drum-shaped container with HE forms one arm and the detonator cable acts as the other. Even if the HE is in a facility converted into a ''Faraday cage'', a lightning strike to the facility could still produce electric fields inside. The detonator cable concentratesmore » the electric field and carries the energy into the detonator, potentially creating a hazard. This electromagnetic (EM) field coupling of lightning energy is the indirect effect of a lightning strike. In practice, ''Faraday cages'' are formed by the rebar of the concrete facilities. The individual rebar rods in the roof, walls and floor are normally electrically connected because of the construction technique of using metal wire to tie the pieces together. There are two additional requirements for a good cage. (1) The roof-wall joint and the wall-floor joint must be electrically attached. (2) All metallic penetrations into the facility must also be electrically connected to the rebar. In this report, it is assumed that these conditions have been met, and there is no arcing in the facility structure. Many types of detonators have metal ''cups'' that contain the explosives and thin electrical initiating wires, called bridge wires mounted between two pins. The pins are connected to the detonator cable. The area of concern is between the pins supporting the bridge wire and the metal cup forming the outside of the detonator. Detonator cables usually have two wires, and in this example, both wires generated the same voltage at the detonator bridge wire. This is called the common-mode voltage. The explosive component inside a detonator is relatively sensitive, and any electrical arc is a concern. In a safety analysis, the pin-to-cup voltage, i.e., detonator voltage, must be calculated to decide if an arc will form. If the electric field is known, the voltage between any two points is simply the integral of the field along a line between the points. Eq. 1.1. For simplicity, it is assumed that the electric field and dipole elements are aligned. Calculating the induced detonator voltage is more complex because of the field concentration caused by metal components. If the detonator cup is not electrically connected to the metal HE container, the portion of the voltage generated by the dipole at the detonator will divide between the container-to-cup and cup-to-pin gaps. The gap voltages are determined by their capacitances. As a simplification, it will be assumed the cup is electrically attached, short circuited, to the HE container. The electrical field in the pin-to-cup area is determined by the field near the dipole, the length of the dipole, the shape of the arms, and the orientation of the arms. Given the characteristics of a lightning strike and the inductance of the facility, the electric fields in the ''Faraday cage'' can be calculated. The important parameters for determining the voltage in an empty facility are the inductance of the rebars and the rate of change of the current, Eq. 1.3. The internal electric fields are directly related to the facility voltages, however, the electric fields in the pin-to-cup space is much higher than the facility fields because the antenna will concentrate the fields covered by the arms. Because the lightning current rise-time is different for every strike, the maximum electric field and the induced detonator voltage should be described by probability distributions. For pedantic purposes, the peak field in the simulations will be simply set to 1 V/m. Lightning induced detonator voltages can be calculated by scaling up with the facility fields. Any metal object around the explosives, such as a work stand, will also distort the electric fields. A computer simulation of the electric fields in a facility with a work stand and HE container is shown. In this configuration, the work stand is grounded, and the intensity of field around the HE (denoted in dark blue) is reduced relative to the rest of the work bay (denoted lighter blue). The area above work stand posts has much higher fields indicated by red. The fields on top of the container are also affected. Without an understanding of how the electric fields are distributed near the detonator cable and container, it is not possible to calculate the induced detonator voltage. The average lightning current has rise- and fall-times of 3 us and 50 us respectively, and this translates to a wavelength that is long when compared with the length of the HE container or detonator cable.« less

  16. Basic Restriction and Reference Level in Anatomically-based Japanese Models for Low-Frequency Electric and Magnetic Field Exposures

    NASA Astrophysics Data System (ADS)

    Takano, Yukinori; Hirata, Akimasa; Fujiwara, Osamu

    Human exposed to electric and/or magnetic fields at low frequencies may cause direct effect such as nerve stimulation and excitation. Therefore, basic restriction is regulated in terms of induced current density in the ICNIRP guidelines and in-situ electric field in the IEEE standard. External electric or magnetic field which does not produce induced quantities exceeding the basic restriction is used as a reference level. The relationship between the basic restriction and reference level for low-frequency electric and magnetic fields has been investigated using European anatomic models, while limited for Japanese model, especially for electric field exposures. In addition, that relationship has not well been discussed. In the present study, we calculated the induced quantities in anatomic Japanese male and female models exposed to electric and magnetic fields at reference level. A quasi static finite-difference time-domain (FDTD) method was applied to analyze this problem. As a result, spatially averaged induced current density was found to be more sensitive to averaging algorithms than that of in-situ electric field. For electric and magnetic field exposure at the ICNIRP reference level, the maximum values of the induced current density for different averaging algorithm were smaller than the basic restriction for most cases. For exposures at the reference level in the IEEE standard, the maximum electric fields in the brain were larger than the basic restriction in the brain while smaller for the spinal cord and heart.

  17. Medicare and Medicaid Programs; Fire Safety Requirements for Certain Health Care Facilities. Final rule.

    PubMed

    2016-05-04

    This final rule will amend the fire safety standards for Medicare and Medicaid participating hospitals, critical access hospitals (CAHs), long-term care facilities, intermediate care facilities for individuals with intellectual disabilities (ICF-IID), ambulatory surgery centers (ASCs), hospices which provide inpatient services, religious non-medical health care institutions (RNHCIs), and programs of all-inclusive care for the elderly (PACE) facilities. Further, this final rule will adopt the 2012 edition of the Life Safety Code (LSC) and eliminate references in our regulations to all earlier editions of the Life Safety Code. It will also adopt the 2012 edition of the Health Care Facilities Code, with some exceptions.

  18. East Spar: Alliance approach for offshore gasfield development

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1998-04-01

    East spar is a gas/condensate field 25 miles west of Barrow Island, offshore Western Australia. Proved plus probable reserves at the time of development were estimated at 430 Bcf gas and 28 million bbl of condensate. The field was discovered in early 1993 when the Western Australia gas market was deregulated and the concept of a gas pipeline to the gold fields was proposed. This created a window of opportunity for East Spar, but only if plans could be established quickly. A base-case development plan was established to support gas marketing while alternative plans could be developed in parallel. Themore » completed East Spar facilities comprise two subsea wells, a subsea gathering system, and a multiphase (gas/condensate/water) pipeline to new gas-processing facilities. The subsea facilities are controlled through a navigation, communication, and control (NCC) buoy. The control room and gas-processing plant are 39 miles east of the field on Varanus Island. Sales gas is exported through a pre-existing gas-sales pipeline to the Dampier-Bunbury and Goldfields Gas Transmission pipelines. Condensate is stored in and exported by use of pre-existing facilities on Varanus Island. Field development from approval to first production took 22 months. The paper describes its field development.« less

  19. Nuclear facility decommissioning and site remedial actions: a selected bibliography. Volume 5

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Owen, P.T.; Knox, N.P.; Chilton, B.D.

    1984-09-01

    This bibliography of 756 references with abstracts on the subject of nuclear facility decommissioning, uranium mill tailings management, and site remedial actions is the fifth in a series of annual reports prepared for the US Department of Energy, Division of Remedial Action Projects. Foreign as well as domestic literature of all types - technical reports, progress reports, journal articles, conference papers, symposium proceedings, theses, books, patents, legislation, and research project descriptions - has been included in this publication. The bibliography contains scientific (basic research as well as applied technology), economic, regulatory, and legal literature pertinent to the US Department ofmore » Energy's Remedial Action Program. Major chapters are: (1) Surplus Facilities Management Program; (2) Nuclear Facilities Decommissioning; (3) Formerly Utilized Sites Remedial Action Program; (4) Uranium Mill Tailings Remedial Action Program; (5) Grand Junction Remedial Action Program; (6) Uranium Mill Tailings Management; and (7) Technical Measurements Center. Chapter sections for chapters 1, 2, 4, and 6 include Design, Planning, and Regulations; Environmental Studies and Site Surveys; Decontamination Studies; Dismantlement and Demolition; Site Stabilization and Reclamation; Waste Disposal; Remedial Action Experience; and General Studies. The references within each chapter or section are arranged alphabetically by leading author. References having no individual author are arranged by corporate author or by title. Indexes are provided for the categories of author, corporate affiliation, title, publication description, geographic location, and keywords. The Appendix contains a list of frequently used acronyms.« less

  20. Testing new technologies for the LISA Gravitational Reference Senso

    NASA Astrophysics Data System (ADS)

    Conklin, John; Chilton, Andrew; Olatunde, Taiwo; Apple, Stephen; Ciani, Giacomo; Mueller, Guido

    2015-01-01

    LISA will directly observe low-frequency gravitational waves emitted by sources ranging from super-massive black hole mergers to compact galactic binaries. A laser interferometer will measure picometer changes in the distances between free falling test masses separated by millions of kilometers. A test mass and its associated sensing, actuation, charge control and caging subsystems are referred to as a gravitational reference sensor (GRS). The demanding acceleration noise requirement of < 3×10-15 m/sec2Hz1/2 for the LISA GRS has motivated a rigorous testing campaign in Europe and a dedicated technology mission, LISA Pathfinder, scheduled for launch in the summer of 2015. At the University of Florida we are developing a nearly thermally noise limited torsion pendulum for testing GRS technology enhancements and for understanding the dozens of acceleration noise sources that affect the performance of the GRS. This experimental facility is based on the design of a similar facility at the University of Trento, and consists of a vacuum enclosed torsion pendulum that suspends mock-ups of the LISA test masses, surrounded by electrode housings. Some of the technologies that will be demonstrated by this facility include a novel TM charge control scheme based on ultraviolet LEDs, an all-optical TM position and attitude sensor, and drift mode operation. This presentation will describe the design of the torsion pendulum facility, its current acceleration noise performance, and the status of the GRS technologies under development.

  1. Application of GPS and Near-Surface Geophysical Methods to Evaluate Agricultural Test Plot Differences

    USDA-ARS?s Scientific Manuscript database

    A field research facility with two pairs of replicated agricultural test plots (four total) was established at a location in northwest Ohio during 2005 for the purpose of studying water table management strategies. Initial efforts at this field research facility were devoted to evaluating difference...

  2. 29. PLAN OF THE ARVFS FIELD TEST FACILITY SHOWING BUNKER, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    29. PLAN OF THE ARVFS FIELD TEST FACILITY SHOWING BUNKER, CABLE CHASE, SHIELDING TANK AND FRAME ASSEMBLY. F.C. TORKELSON DRAWING NUMBER 842-ARVFS-701-1. INEL INDEX CODE NUMBER: 075 0701 851 151970. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID

  3. Emissions of PCDD and PCDF from combustion of forest fuels and sugarcane: a comparison between field measurements and simulations in a laboratory burn facility.

    PubMed

    Black, R R; Meyer, C P; Touati, A; Gullett, B K; Fiedler, H; Mueller, J F

    2011-05-01

    Release of PCDD and PCDF from biomass combustion such as forest and agricultural crop fires has been nominated as an important source for these chemicals despite minimal characterisation. Available emission factors that have been experimentally determined in laboratory and field experiments vary by several orders of magnitude from <0.5 μg TEQ (t fuel consumed)(-1) to >100 μg TEQ (t fuel consumed)(-1). The aim of this study was to evaluate the effect of experimental methods on the emission factor. A portable field sampler was used to measure PCDD/PCDF emissions from forest fires and the same fuel when burnt over a brick hearth to eliminate potential soil effects. A laboratory burn facility was used to sample emissions from the same fuels. There was very good agreement in emission factors to air (EF(Air)) for forest fuel (Duke Forest, NC) of 0.52 (range: 0.40-0.79), 0.59 (range: 0.18-1.2) and 0.75 (range: 0.27-1.2) μg TEQ(WHO2005) (t fuel consumed)(-1) for the in-field, over a brick hearth, and burn facility experiments, respectively. Similarly, experiments with sugarcane showed very good agreement with EF(Air) of 1.1 (range: 0.40-2.2), 1.5 (range: 0.84-2.2) and 1.7 (range: 0.34-4.4) μg TEQ (t fuel consumed)(-1) for in-field, over a brick hearth, open field and burn facility experiments respectively. Field sampling and laboratory simulations were in good agreement, and no significant changes in emissions of PCDD/PCDF could be attributed to fuel storage and transport to laboratory test facilities. Copyright © 2011 Elsevier Ltd. All rights reserved.

  4. The emergence of care facilities in Thailand for older German-speaking people: structural backgrounds and facility operators as transnational actors.

    PubMed

    Bender, Désirée; Hollstein, Tina; Schweppe, Cornelia

    2017-12-01

    This paper presents findings from an ethnographic study of old age care facilities for German-speaking people in Thailand. It analyses the conditions and processes behind the development and specific designs of such facilities. It first looks at the intertwinement, at the socio-structural level, of different transborder developments in which the facilities' emergence is embedded. Second, it analyses the processes that accompany the emergence, development and organisation of these facilities at the local level. In this regard, it points out the central role of the facility operators as transnational actors who mediate between different frames of reference and groups of actors involved in these facilities. It concludes that the processes of mediation and intertwining are an important and distinctive feature of the emergence of these facilities, necessitated by the fact that, although the facilities are located in Thailand, their 'markets' are in the German-speaking countries of their target groups.

  5. Magnetohydrodynamics (MHD) Engineering Test Facility (ETF) 200 MWe power plant Conceptual Design Engineering Report (CDER)

    NASA Technical Reports Server (NTRS)

    1981-01-01

    The reference conceptual design of the magnetohydrodynamic (MHD) Engineering Test Facility (ETF), a prototype 200 MWe coal-fired electric generating plant designed to demonstrate the commercial feasibility of open cycle MHD, is summarized. Main elements of the design, systems, and plant facilities are illustrated. System design descriptions are included for closed cycle cooling water, industrial gas systems, fuel oil, boiler flue gas, coal management, seed management, slag management, plant industrial waste, fire service water, oxidant supply, MHD power ventilating

  6. The construction technology of Chinese ancient city drainage facilities

    NASA Astrophysics Data System (ADS)

    Hequn, Li; Yufengyun

    2018-03-01

    In ancient china, according to the local natural environment, a variety of drainage facilities were built in order to excrete rainwater, domestic sewage, production wastewater and so on. These drainage facilities were mainly made of pottery, bricks, wood, stone, etc. For example, ceramic water pipelines, buried in the ground, connect together one by one, and there was a slight drop from one end to the other in favor of drainage. These measures can also be used for reference in today’s urban drainage and flood control.

  7. Magnetohydrodynamics (MHD) Engineering Test Facility (ETF) 200 MWe power plant Conceptual Design Engineering Report (CDER)

    NASA Astrophysics Data System (ADS)

    1981-09-01

    The reference conceptual design of the magnetohydrodynamic (MHD) Engineering Test Facility (ETF), a prototype 200 MWe coal-fired electric generating plant designed to demonstrate the commercial feasibility of open cycle MHD, is summarized. Main elements of the design, systems, and plant facilities are illustrated. System design descriptions are included for closed cycle cooling water, industrial gas systems, fuel oil, boiler flue gas, coal management, seed management, slag management, plant industrial waste, fire service water, oxidant supply, MHD power ventilating

  8. Reference earth orbital research and applications investigations (blue book). Volume 8: Life sciences

    NASA Technical Reports Server (NTRS)

    1971-01-01

    The functional program element for the life sciences facilities to operate aboard manned space stations is presented. The life sciences investigations will consist of the following subjects: (1) medical research, (2) vertebrate research, (3) plant research, (4) cells and tissue research, (5) invertebrate research, (6) life support and protection, and (7) man-system integration. The equipment required to provide the desired functional capability for the research facilities is defined. The goals and objectives of each research facility are described.

  9. Major Range and Test Facility Base Summary of Capabilities.

    DTIC Science & Technology

    1983-06-01

    TEST CHART NATIONAL BUREAU OF STANDARDS 1963 A 3,i 4, S °.I i L -. ~ . % o,. ° . - ° . - . .I ¢ PHOTOGRAPH THIS SHEET LEVEL INVENTORY DOCUMENT...NUMBER DOD 3200.11-D 4. TTLE(~dS..tt~t@) S TYPE Of REPORT a PERIO’ COVERED Major Range and Test Facility Base Summary Reference Maerial of Capabilities...Electronic Warfare, Command, Control Communications and Intelligence (C31) Surveillance, Jammers, Radar, Test Facility ZG5 ABETW ACT f~ a "Afie Afr- s 444 eF~f

  10. Reference earth orbital research and applications investigations (blue book). Volume 4: Earth observations

    NASA Technical Reports Server (NTRS)

    1971-01-01

    The earth observations capability of the space station and space shuttle program definition is discussed. The stress in the functional program element has been to update the sensor specifications and to shift some of the emphasis from sensors to experiments to be done aboard the facility. The earth observations facility will include provisions for data acquisition, sensor control and display, data analysis, and maintenance and repair. The facility is research and development in nature with a potential for operational applications.

  11. Availability analysis of an HTGR fuel recycle facility. Summary report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sharmahd, J.N.

    1979-11-01

    An availability analysis of reprocessing systems in a high-temperature gas-cooled reactor (HTGR) fuel recycle facility was completed. This report summarizes work done to date to define and determine reprocessing system availability for a previously planned HTGR recycle reference facility (HRRF). Schedules and procedures for further work during reprocessing development and for HRRF design and construction are proposed in this report. Probable failure rates, transfer times, and repair times are estimated for major system components. Unscheduled down times are summarized.

  12. Newly emerging resource efficiency manager programs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wolf, S.; Howell, C.

    1997-12-31

    Many facilities in the northwest such as K--12 schools, community colleges, and military installations are implementing resource-efficiency awareness programs. These programs are generally referred to as resource efficiency manager (REM) or resource conservation manager (RCM) programs. Resource efficiency management is a systems approach to managing a facility`s energy, water, and solid waste. Its aim is to reduce utility budgets by focusing on behavioral changes, maintenance and operation procedures, resource accounting, education and training, and a comprehensive awareness campaign that involves everyone in the organization.

  13. Cryogenic studies for the proposed CERN large hadron electron collider (LHEC)

    NASA Astrophysics Data System (ADS)

    Haug, F.; LHeC Study Team, The

    2012-06-01

    The LHeC (Large Hadron electron Collider) is a proposed future colliding beam facility for lepton-nucleon scattering particle physics at CERN. A new 60 GeV electron accelerator will be added to the existing 27 km circumference 7 TeV LHC for collisions of electrons with protons and heavy ions. Two basic design options are being pursued. The first is a circular accelerator housed in the existing LHC tunnel which is referred to as the "Ring-Ring" version. Low field normal conducting magnets guide the particle beam while superconducting (SC) RF cavities cooled to 2 K are installed at two opposite locations at the LHC tunnel to accelerate the beams. For this version in addition a 10 GeV re-circulating SC injector will be installed. In total four refrigerators with cooling capacities between 1.2 kW and 3 kW @ 4.5 K are needed. The second option, referred to as the "Linac-Ring" version consists of a race-track re-circulating energyrecovery type machine with two 1 km long straight acceleration sections. The 944 high field 2 K SC cavities dissipate 30 kW at CW operation. Eight 10 kW @ 4.5 K refrigerators are proposed. The particle detector contains a combined SC solenoid and dipole forming the cold mass and an independent liquid argon calorimeter. Cooling is done with two individual small sized cryoplants; a 4.5 K helium, and a 87 K liquid nitrogen plant.

  14. Hanford Facility dangerous waste permit application, liquid effluent retention facility and 200 area effluent treatment facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coenenberg, J.G.

    1997-08-15

    The Hanford Facility Dangerous Waste Permit Application is considered to 10 be a single application organized into a General Information Portion (document 11 number DOE/RL-91-28) and a Unit-Specific Portion. The scope of the 12 Unit-Specific Portion is limited to Part B permit application documentation 13 submitted for individual, `operating` treatment, storage, and/or disposal 14 units, such as the Liquid Effluent Retention Facility and 200 Area Effluent 15 Treatment Facility (this document, DOE/RL-97-03). 16 17 Both the General Information and Unit-Specific portions of the Hanford 18 Facility Dangerous Waste Permit Application address the content of the Part B 19 permit applicationmore » guidance prepared by the Washington State Department of 20 Ecology (Ecology 1987 and 1996) and the U.S. Environmental Protection Agency 21 (40 Code of Federal Regulations 270), with additional information needs 22 defined by the Hazardous and Solid Waste Amendments and revisions of 23 Washington Administrative Code 173-303. For ease of reference, the Washington 24 State Department of Ecology alpha-numeric section identifiers from the permit 25 application guidance documentation (Ecology 1996) follow, in brackets, the 26 chapter headings and subheadings. A checklist indicating where information is 27 contained in the Liquid Effluent Retention Facility and 200 Area Effluent 28 Treatment Facility permit application documentation, in relation to the 29 Washington State Department of Ecology guidance, is located in the Contents 30 Section. 31 32 Documentation contained in the General Information Portion is broader in 33 nature and could be used by multiple treatment, storage, and/or disposal units 34 (e.g., the glossary provided in the General Information Portion). Wherever 35 appropriate, the Liquid Effluent Retention Facility and 200 Area Effluent 36 Treatment Facility permit application documentation makes cross-reference to 37 the General Information Portion, rather than duplicating text. 38 39 Information provided in this Liquid Effluent Retention Facility and 40 200 Area Effluent Treatment Facility permit application documentation is 41 current as of June 1, 1997.« less

  15. Investigating Pu and U isotopic compositions in sediments: a case study in Lake Obuchi, Rokkasho Village, Japan using sector-field ICP-MS and ICP-QMS.

    PubMed

    Zheng, Jian; Yamada, Masatoshi

    2005-08-01

    The objectives of the present work were to study isotope ratios and the inventory of plutonium and uranium isotope compositions in sediments from Lake Obuchi, which is in the vicinity of several nuclear fuel facilities in Rokkasho, Japan. Pu and its isotopes were determined using sector-field ICP-MS and U and its isotopes were determined with ICP-QMS after separation and purification with a combination of ion-exchange and extraction chromatography. The observed (240)Pu/(239)Pu atom ratio (0.186 +/- 0.016) was similar to that of global fallout, indicating that the possible early tropospheric fallout Pu did not deliver Pu from the Pacific Proving Ground to areas above 40 degrees N. The previously reported higher Pu inventory in the deep water area of Lake Obuchi could be attributed to the lateral transportation of Pu deposited in the shallow area which resulted from the migration of deposited global fallout Pu from the land into the lake by river runoff and from the Pacific Ocean by tide movement and sea water scavenging, as well as from direct soil input by winds. The (235)U/(238)U atom ratios ranged from 0.00723 to 0.00732, indicating the natural origin of U in the sediments. The average (234)U/(238)U activity ratio of 1.11 in a sediment core indicated a significant sea water U contribution. No evidence was found for the release of U containing wastes from the nearby nuclear facilities. These results will serve as a reference baseline on the levels of Pu and U in the studied site so that any further contamination from the spent nuclear fuel reprocessing plants, the radioactive waste disposal and storage facilities, and the uranium enrichment plant can be identified, and the impact of future release can be rapidly assessed.

  16. Decadal GPS Time Series and Velocity Fields Spanning the North American Continent and Beyond: New Data Products, Cyberinfrastructure and Case Studies from the EarthScope Plate Boundary Observatory (PBO) and Other Regional Networks

    NASA Astrophysics Data System (ADS)

    Phillips, D. A.; Herring, T.; Melbourne, T. I.; Murray, M. H.; Szeliga, W. M.; Floyd, M.; Puskas, C. M.; King, R. W.; Boler, F. M.; Meertens, C. M.; Mattioli, G. S.

    2017-12-01

    The Geodesy Advancing Geosciences and EarthScope (GAGE) Facility, operated by UNAVCO, provides a diverse suite of geodetic data, derived products and cyberinfrastructure services to support community Earth science research and education. GPS data and products including decadal station position time series and velocities are provided for 2000+ continuous GPS stations from the Plate Boundary Observatory (PBO) and other networks distributed throughout the high Arctic, North America, and Caribbean regions. The position time series contain a multitude of signals in addition to the secular motions, including coseismic and postseismic displacements, interseismic strain accumulation, and transient signals associated with hydrologic and other processes. We present our latest velocity field solutions, new time series offset estimate products, and new time series examples associated with various phenomena. Position time series, and the signals they contain, are inherently dependent upon analysis parameters such as network scaling and reference frame realization. The estimation of scale changes for example, a common practice, has large impacts on vertical motion estimates. GAGE/PBO velocities and time series are currently provided in IGS (IGb08) and North America (NAM08, IGb08 rotated to a fixed North America Plate) reference frames. We are reprocessing all data (1996 to present) as part of the transition from IGb08 to IGS14 that began in 2017. New NAM14 and IGS14 data products are discussed. GAGE/PBO GPS data products are currently generated using onsite computing clusters. As part of an NSF funded EarthCube Building Blocks project called "Deploying MultiFacility Cyberinfrastructure in Commercial and Private Cloud-based Systems (GeoSciCloud)", we are investigating performance, cost, and efficiency differences between local computing resources and cloud based resources. Test environments include a commercial cloud provider (Amazon/AWS), NSF cloud-like infrastructures within XSEDE (TACC, the Texas Advanced Computing Center), and in-house cyberinfrastructures. Preliminary findings from this effort are presented. Web services developed by UNAVCO to facilitate the discovery, customization and dissemination of GPS data and products are also presented.

  17. The Spanish General Radioactive Waste Management Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Espejo, J.M.; Abreu, A.

    This paper mainly describes the strategies, the necessary actions and the technical solutions to be developed by ENRESA in the short, medium and long term, aimed at ensuring the adequate management of radioactive waste, the dismantling and decommissioning of nuclear and radioactive facilities and other activities, including economic and financial measures required to carry them out. Starting with the Spanish administrative organization in this field, which identifies the different agents involved and their roles, and after referring to the waste generation, the activities to be performed in the areas of LILW, SF and HLW management, decommissioning of installations and othersmore » are summarized. Finally, the future management costs are estimated and the financing system currently in force is explained. The so-called Sixth General Radioactive Waste Plan (6. GRWP), approved by the Spanish Government, is the 'master document' of reference where all the above mentioned issues are contemplated. In summary: The 6. GRWP includes the strategies and actions to be performed by Enresa in the coming years. The document, revised by the Government and subject to a process of public information, underlines the fact that Spain possesses an excellent infrastructure for the safe and efficient management of radioactive waste, from the administrative, technical and economic-financial points of view. From the administrative point of view there is an organisation, supported by ample legislative developments, that contemplates and governs the main responsibilities of the parties involved in the process (Government, CSN, ENRESA and waste producers). As regards the technical aspect, the experience accumulated to date by Enresa is particularly significant, as are the technologies now available in the field of management and for dismantling processes. As regards the economic-financial basis, a system is in place that guarantees the financing of radioactive waste management costs. This system is based on the generation of funds up front, during the operating lifetime of the facilities, through the application of fees established by Statutory provisions. Finally, a mandatory mechanism of annual revision for both technical issues and economic and financial aspects, allows to have updated all the courses of action. (authors)« less

  18. Review of Army Officer Educational System. Volume 1. Summary Report

    DTIC Science & Technology

    1971-12-01

    13-5 V. StaffingGuide. . . . . . . . .. 13-6 VI. Academic Facilities .................. 13-9 VII. Educational Innovations . . . . . .... . 13-10 14...report does not lean heavily on statistical support. It gives references, research, and statistical data only when essential to validity, accuracy, or...Leadership, History, Interbranch and Interservice Education , Facilities , Regulations, Staffing Guide, Educational Innovations Chapter 14 - Concluding

  19. Documentation and Evaluation of Depot Maintenance Cost Accumulation and Reporting at the Naval Air Rework Facility, Jacksonville, Florida.

    DTIC Science & Technology

    1984-06-01

    Barilla , 1984). B. NARF JACKSONVILLE 1. Activities and Services NARF Jacksonville is one of the six industrially funded maintenance facilities which...MC =arine Corps N =Navy DSA z Defense Security Assistance OFA - Other Federal Agencies NFA a Non-Federal Agencies 80 1" 6 LIST OF REFERENCES Barilla

  20. MECHANIZATION STUDY OF THE TECHNICAL LIBRARY U.S. NAVAL AVIONICS FACILITY, INDIANAPOLIS, INDIANA.

    ERIC Educational Resources Information Center

    KERSHAW, G.A.; AND OTHERS

    THE NAVAL AVIONICS FACILITY, INDIANAPOLIS (NAFI) TECHNICAL LIBRARY IS PLANNING A MECHANIZED SYSTEM TO PRODUCE A PERMUTED INDEX OF PERTINENT PERIODICAL REFERENCES AND PROCEEDINGS, WITH BOOKS AND DOCUMENTS TO BE ADDED LATER. INPUT TO THE SYSTEM IS PUNCHED PAPER TAPE PREPARED FROM THE SOURCE MATERIAL, AND THE PRIMARY PROGRAM IS A "CANNED"…

  1. Effects of space exposure on metals flown on the Long Duration Exposure Facility

    NASA Technical Reports Server (NTRS)

    Pippin, H. Gary; Bourassa, R. J.

    1995-01-01

    This report includes measurements on copper, aluminum, and stainless steel from the Long Duration Exposure Facility (LDEF). Summaries of the performance of a variety of metals flown on LDEF are presented. An extensive list of references directs the reader to other detailed investigations. The influence of contamination on a number of measurements is documented.

  2. 50 CFR 80.51 - What activities are eligible for funding under the Dingell-Johnson Sport Fish Restoration Act?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... program. (1) Restore and manage sport fish for the benefit of the public. (2) Conduct research on the..., also referred to as a “waste reception facility,” is specifically designed to receive waste from... of recreational boating access facilities. (2) Conduct surveys to determine the adequacy, number...

  3. 50 CFR 80.51 - What activities are eligible for funding under the Dingell-Johnson Sport Fish Restoration Act?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...) Restore and manage sport fish for the benefit of the public. (2) Conduct research on the problems of..., also referred to as a “waste reception facility,” is specifically designed to receive waste from... of recreational boating access facilities. (2) Conduct surveys to determine the adequacy, number...

  4. 50 CFR 80.51 - What activities are eligible for funding under the Dingell-Johnson Sport Fish Restoration Act?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...) Restore and manage sport fish for the benefit of the public. (2) Conduct research on the problems of..., also referred to as a “waste reception facility,” is specifically designed to receive waste from... of recreational boating access facilities. (2) Conduct surveys to determine the adequacy, number...

  5. 50 CFR 80.51 - What activities are eligible for funding under the Dingell-Johnson Sport Fish Restoration Act?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... program. (1) Restore and manage sport fish for the benefit of the public. (2) Conduct research on the..., also referred to as a “waste reception facility,” is specifically designed to receive waste from... of recreational boating access facilities. (2) Conduct surveys to determine the adequacy, number...

  6. Hematologic and serum biochemistry reference values in wild-caught white-footed tamarins (Saguinus leucopus) housed in captivity.

    PubMed

    Fox, Maureen; Brieva, Claudia; Moreno, Carlos; MacWilliams, Peter; Thomas, Chet

    2008-12-01

    The white-footed tamarin (Saguinus leucopus) is an endangered primate that lives in a small forest corridor in northern Colombia, South America. Hematologic and serum biochemistry reference values are important tools in evaluating the health of the white-footed tamarin and serve to promote the survival of this species. The purpose of this study was to establish diagnostically important hematologic and serum biochemistry reference values for healthy white-footed tamarins and to determine whether there was significant variation with respect to age class (juveniles, adults), gender, and housing facility. Blood samples were collected for hematologic and serum biochemistry measurements from 29 wild-caught captive tamarins during February and April 2005, housed at three different facilities in central Colombia. Hematology and serum biochemistry values were similar in adults and juveniles. Female white-footed tamarins had absolute reticulocyte counts that were lower than those of male tamarins and males had lower serum chloride concentrations than female tamarins. Mean values for hemoglobin, mean cell hemoglobin, serum total protein, albumin, glucose, and alkaline phosphatase varied among the three housing facilities. Twenty-two of the 29 tamarins sampled were microfilaria-positive and had significantly higher mean serum alkaline phosphatase concentrations. Among the 29 tamarins sampled in this study, serum values for mean alkaline phosphatase and creatine kinase concentrations were higher than reported values for other mammals. The reference intervals determined in this study were comparable to normal ranges reported for other members of the family Callitrichidae.

  7. Towards elimination of mother-to-child transmission of HIV: performance of different models of care for initiating lifelong antiretroviral therapy for pregnant women in Malawi (Option B+).

    PubMed

    van Lettow, Monique; Bedell, Richard; Mayuni, Isabell; Mateyu, Gabriel; Landes, Megan; Chan, Adrienne K; van Schoor, Vanessa; Beyene, Teferi; Harries, Anthony D; Chu, Stephen; Mganga, Andrew; van Oosterhout, Joep J

    2014-01-01

    Malawi introduced a new strategy to improve the effectiveness of prevention of mother-to-child HIV transmission (PMTCT), the Option B+ strategy. We aimed to (i) describe how Option B+ is provided in health facilities in the South East Zone in Malawi, identifying the diverse approaches to service organization (the "model of care") and (ii) explore associations between the "model of care" and health facility-level uptake and retention rates for pregnant women identified as HIV-positive at antenatal (ANC) clinics. A health facility survey was conducted in all facilities providing PMTCT/antiretroviral therapy (ART) services in six of Malawi's 28 districts to describe and compare Option B+ service delivery models. Associations of identified models with program performance were explored using facility cohort reports. Among 141 health facilities, four "models of care" were identified: A) facilities where newly identified HIV-positive women are initiated and followed on ART at the ANC clinic until delivery; B) facilities where newly identified HIV-positive women receive only the first dose of ART at the ANC clinic, and are referred to the ART clinic for follow-up; C) facilities where newly identified HIV-positive women are referred from ANC to the ART clinic for initiation and follow-up of ART; and D) facilities serving as ART referral sites (not providing ANC). The proportion of women tested for HIV during ANC was highest in facilities applying Model A and lowest in facilities applying Model B. The highest retention rates were reported in Model C and D facilities and lowest in Model B facilities. In multivariable analyses, health facility factors independently associated with uptake of HIV testing and counselling (HTC) in ANC were number of women per HTC counsellor, HIV test kit availability, and the "model of care" applied; factors independently associated with ART retention were district location, patient volume and the "model of care" applied. A large variety exists in the way health facilities have integrated PMTCT Option B+ care into routine service delivery. This study showed that the "model of care" chosen is associated with uptake of HIV testing in ANC and retention in care on ART. Further patient-level research is needed to guide policy recommendations.

  8. Safety Analysis and Protection Measures of the Control System of the Pulsed High Magnetic Field Facility in WHMFC

    NASA Astrophysics Data System (ADS)

    Shi, J. T.; Han, X. T.; Xie, J. F.; Yao, L.; Huang, L. T.; Li, L.

    2013-03-01

    A Pulsed High Magnetic Field Facility (PHMFF) has been established in Wuhan National High Magnetic Field Center (WHMFC) and various protection measures are applied in its control system. In order to improve the reliability and robustness of the control system, the safety analysis of the PHMFF is carried out based on Fault Tree Analysis (FTA) technique. The function and realization of 5 protection systems, which include sequence experiment operation system, safety assistant system, emergency stop system, fault detecting and processing system and accident isolating protection system, are given. The tests and operation indicate that these measures improve the safety of the facility and ensure the safety of people.

  9. The Granite Mountain Atmospheric Sciences Testbed (GMAST): A Facility for Long Term Complex Terrain Airflow Studies

    NASA Astrophysics Data System (ADS)

    Zajic, D.; Pace, J. C.; Whiteman, C. D.; Hoch, S.

    2011-12-01

    This presentation describes a new facility at Dugway Proving Ground (DPG), Utah that can be used to study airflow over complex terrain, and to evaluate how airflow over a mountain barrier affects wind patterns over adjacent flatter terrain. DPG's primary mission is to conduct testing, training, and operational assessments of chemical and biological weapon systems. These operations require very precise weather forecasts. Most test operations at DPG are conducted on fairly flat test ranges having uniform surface cover, where airflow patterns are generally well-understood. However, the DPG test ranges are located alongside large, isolated mountains, most notably Granite Mountain, Camelback Mountain, and the Cedar Mountains. Airflows generated over, or influenced by, these mountains can affect wind patterns on the test ranges. The new facility, the Granite Mountain Atmospheric Sciences Testbed, or GMAST, is designed to facilitate studies of airflow interactions with topography. This facility will benefit DPG by improving understanding of how mountain airflows interact with the test range conditions. A core infrastructure of weather sensors around and on Granite Mountain has been developed including instrumented towers and remote sensors, along with automated data collection and archival systems. GMAST is expected to be in operation for a number of years and will provide a reference domain for mountain meteorology studies, with data useful for analysts, modelers and theoreticians. Visiting scientists are encouraged to collaborate with DPG personnel to utilize this valuable scientific resource and to add further equipment and scientific designs for both short-term and long-term atmospheric studies. Several of the upcoming MATERHORN (MountAin TERrain atmospHeric mOdeling and obseRvatioNs) project field tests will be conducted at DPG, giving an example of GMAST utilization and collaboration between DPG and visiting scientists.

  10. Estimation Filter for Alignment of the Spitzer Space Telescope

    NASA Technical Reports Server (NTRS)

    Bayard, David

    2007-01-01

    A document presents a summary of an onboard estimation algorithm now being used to calibrate the alignment of the Spitzer Space Telescope (formerly known as the Space Infrared Telescope Facility). The algorithm, denoted the S2P calibration filter, recursively generates estimates of the alignment angles between a telescope reference frame and a star-tracker reference frame. At several discrete times during the day, the filter accepts, as input, attitude estimates from the star tracker and observations taken by the Pointing Control Reference Sensor (a sensor in the field of view of the telescope). The output of the filter is a calibrated quaternion that represents the best current mean-square estimate of the alignment angles between the telescope and the star tracker. The S2P calibration filter incorporates a Kalman filter that tracks six states - two for each of three orthogonal coordinate axes. Although, in principle, one state per axis is sufficient, the use of two states per axis makes it possible to model both short- and long-term behaviors. Specifically, the filter properly models transient learning, characteristic times and bounds of thermomechanical drift, and long-term steady-state statistics, whether calibration measurements are taken frequently or infrequently. These properties ensure that the S2P filter performance is optimal over a broad range of flight conditions, and can be confidently run autonomously over several years of in-flight operation without human intervention.

  11. Methods for Scaling Icing Test Conditions

    NASA Technical Reports Server (NTRS)

    Anderson, David N.

    1995-01-01

    This report presents the results of tests at NASA Lewis to evaluate several methods to establish suitable alternative test conditions when the test facility limits the model size or operating conditions. The first method was proposed by Olsen. It can be applied when full-size models are tested and all the desired test conditions except liquid-water content can be obtained in the facility. The other two methods discussed are: a modification of the French scaling law and the AEDC scaling method. Icing tests were made with cylinders at both reference and scaled conditions representing mixed and glaze ice in the NASA Lewis Icing Research Tunnel. Reference and scale ice shapes were compared to evaluate each method. The Olsen method was tested with liquid-water content varying from 1.3 to .8 g/m(exp3). Over this range, ice shapes produced using the Olsen method were unchanged. The modified French and AEDC methods produced scaled ice shapes which approximated the reference shapes when model size was reduced to half the reference size for the glaze-ice cases tested.

  12. Comparison Between the NIST and the KEBS for the Determination of Air Kerma Calibration Coefficients for Narrow X-Ray Spectra and 137Cs Gamma-Ray Beams

    PubMed Central

    O’Brien, Michelle; Minniti, Ronaldo; Masinza, Stanslaus Alwyn

    2010-01-01

    Air kerma calibration coefficients for a reference class ionization chamber from narrow x-ray spectra and cesium 137 gamma-ray beams were compared between the National Institute of Standards and Technology (NIST) and the Kenya Bureau of Standards (KEBS). A NIST reference-class transfer ionization chamber was calibrated by each laboratory in terms of the quantity air kerma in four x-ray reference radiation beams of energies between 80 kV and 150 kV and in a cesium 137 gamma-ray beam. The reference radiation qualities used for this comparison are described in detail in the ISO 4037 publication.[1] The comparison began in September 2008 and was completed in March 2009. The results reveal the degree to which the participating calibration facility can demonstrate proficiency in transferring air kerma calibrations under the conditions of the said facility at the time of the measurements. The comparison of the calibration coefficients is based on the average ratios of calibration coefficients. PMID:27134777

  13. Comparison Between the NIST and the KEBS for the Determination of Air Kerma Calibration Coefficients for Narrow X-Ray Spectra and (137)Cs Gamma-Ray Beams.

    PubMed

    O'Brien, Michelle; Minniti, Ronaldo; Masinza, Stanslaus Alwyn

    2010-01-01

    Air kerma calibration coefficients for a reference class ionization chamber from narrow x-ray spectra and cesium 137 gamma-ray beams were compared between the National Institute of Standards and Technology (NIST) and the Kenya Bureau of Standards (KEBS). A NIST reference-class transfer ionization chamber was calibrated by each laboratory in terms of the quantity air kerma in four x-ray reference radiation beams of energies between 80 kV and 150 kV and in a cesium 137 gamma-ray beam. The reference radiation qualities used for this comparison are described in detail in the ISO 4037 publication.[1] The comparison began in September 2008 and was completed in March 2009. The results reveal the degree to which the participating calibration facility can demonstrate proficiency in transferring air kerma calibrations under the conditions of the said facility at the time of the measurements. The comparison of the calibration coefficients is based on the average ratios of calibration coefficients.

  14. The current status and future direction of high magnetic field science in the United States

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lancaster, James

    2013-11-01

    This grant provided partial support for the National Research Council (NRC) study that assesses the current status of high magnetic field research in the United States and provides recommendations to guide the future of research and technology development for this area given the needs of user communities and in the context of other programs worldwide. A pdf version of the report is available for download, for free, at http://www.nap.edu/catalog.php?record_id=18355. The science drivers fall into 4 broad areas—(1) condensed matter and materials physics; (2) chemistry, biochemistry, and biology; (3) medical and life science studies; and (4) other fields such as high-energymore » physics, plasma physics, and particle astrophysics. Among the topics covered in the report’s findings, conclusions, and recommendations are a recognition that there is a continuing need for a centralized facility but also that clear benefits will flow to research communities from decentralized facilities. According to the report, support agencies should evaluate whether to establish such facilities when 32 Tesla superconducting magnets become available. The report also recommends the provision of facilities that combine magnetic fields with scattering facilities and THz radiation sources, and sets out specific magnet goals for magnets needed in several areas of research.« less

  15. Sport Fields as Potential Catalysts for Physical Activity in the Neighbourhood

    PubMed Central

    Cutumisu, Nicoleta; Spence, John C.

    2012-01-01

    Physical activity is associated with access to recreational facilities such as sports fields. Because it is not clear whether objectively- or subjectively-assessed access to facilities exerts a stronger influence on physical activity, we investigated the association between the objective and perceived accessibility of sport fields and the levels of self-reported physical activity among adults in Edmonton, Canada. A sample of 2879 respondents was surveyed regarding their socio-demographics, health status, self-efficacy, levels of physical activity, as well as their perceptions of built environment in relation to physical activity. Neighbourhood-level data were obtained for each respondent based on their residence. Accessibility to facilities was assessed using the enhanced Two-Step Floating Catchment Area method. Geographic Information Systems were employed. A logistic regression was performed to predict physical activity using individual- and neighbourhood-level variables. Women, older individuals, and individuals with higher educational attainment were less likely to be physically active. Also, individuals with higher self-efficacy and higher objectively-assessed access to facilities were more likely to be physically active. Interventions that integrate provision of relevant programs for various population groups and of improved recreational facilities may contribute to sport fields becoming catalysts for physical activity by generating movement both on the site and in the neighbourhood. PMID:22470293

  16. Evaluation of Nuclear Facility Decommissioning Projects program: a reference test reactor. Project summary report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boing, L.E.; Miller, R.L.

    1983-10-01

    This document presents, in summary form, generic conceptual information relevant to the decommissioning of a reference test reactor (RTR). All of the data presented were extracted from NUREG/CR-1756 and arranged in a form that will provide a basis for future comparison studies for the Evaluation of Nuclear Facility Decommissioning Projects (ENFDP) program. During the data extraction process no attempt was made to challenge any of the assumptions used in the original studies nor was any attempt made to update assumed methods or processes to state-of-the-art decommissioning techniques. In a few instances obvious errors were corrected after consultation with the studymore » author.« less

  17. Application of GPS and Near-Surface Geophysical Methods to Evaluate Differences Between Agricultural Test Plots

    USDA-ARS?s Scientific Manuscript database

    A field research facility with two pairs of replicated agricultural test plots (four total) was established at a location in northwest Ohio during 2005 for the purpose of studying water table management strategies. Initial efforts at this field research facility were devoted to evaluating difference...

  18. Retrofit of waste-to-energy facilities equipped with electrostatic precipitators. Volume II: Field and Laboratory Reports, Part 1 of 2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rigo, H.G.; Chandler, A.J.

    1996-04-01

    Volume II (part 1 of 2) of ''Retrofit of Waste-to-energy Facilities Equipped with Electrostatic Precipitators'' contains the documentation and raw data, including: (1) field reports, (2) analytic laboratory reports, (3) chain of custody forms, and (4) TCLP laboratory reports.

  19. 75 FR 51258 - Boott Hydropower, Inc.; Eldred L Field Hydroelectric Facility Trust; Notice of Application for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-19

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Project No. 2790-055] Boott Hydropower... Hydropower, Inc. and Eldred L Field Hydroelectric Facility Trust. e. Name of Project: Lowell Hydroelectric... Affairs Coordinator, Boott Hydropower, Inc., One Tech Drive, Suite 220, Andover, MA 01810. Tel: (978) 681...

  20. Penn State axial flow turbine facility: Performance and nozzle flow field

    NASA Technical Reports Server (NTRS)

    Lakshminarayana, B.; Zaccaria, M.; Itoh, S.

    1991-01-01

    The objective is to gain a thorough understanding of the flow field in a turbine stage including three-dimensional inviscid and viscid effects, unsteady flow field, rotor-stator interaction effects, unsteady blade pressures, shear stress, and velocity field in rotor passages. The performance of the turbine facility at the design condition is measured and compared with the design distribution. The data on the nozzle vane static pressure and wake characteristics are presented and interpreted. The wakes are found to be highly three-dimensional, with substantial radial inward velocity at most spanwise locations.

  1. Goddard Space Flight Center Spacecraft Magnetic Test Facility Restoration Project

    NASA Technical Reports Server (NTRS)

    Vernier, Robert; Bonalksy, Todd; Slavin, James

    2004-01-01

    The Goddard Space Flight Center Spacecraft Magnetic Test Facility (SMTF) was constructed in the 1960's for the purpose of simulating geomagnetic and interplanetary magnetic field environments. The facility includes a three axis Braunbek coil system consisting of 12 loops, 4 loops on each of the three orthogonal axes; a remote Earth field sensing magnetometer and servo controller; and a remote power control and instrumentation building. The inner coils of the Braunbek system are 42-foot in diameter with a 10-foot by 10-foot opening through the outer coils to accommodate spacecraft access into the test volume. The physical size and precision of the facility are matched by only two other such facilities in the world. The facility was used extensively from the late 1960's until the early 1990's when the requirement for spacecraft level testing diminished. New NASA missions planned under the Living with a Star, Solar Terrestrial Probes, Explorer, and New Millennium Programs include precision, high-resolution magnetometers to obtain magnetic field data that is critical to fulfilling their scientific mission. It is highly likely that future Lunar and Martian exploration missions will also use precision magnetometers to conduct geophysical magnetic surveys. To ensure the success of these missions, ground-testing using a magnetic test facility such as the GSFC SMTF will be required. This paper describes the history of the facility, the future mission requirements that have renewed the need for spacecraft level magnetic testing, and the plans for restoring the facility to be capable of performing to its original design specifications.

  2. Goddard Space Flight Center Spacecraft Magnetic Test Facility Restoration Project

    NASA Technical Reports Server (NTRS)

    Vernier, Robert; Bonalosky, Todd; Slavin, James

    2004-01-01

    The Goddard Space Flight Center Spacecraft Magnetic Test Facility (SMTF) was constructed in the 1960's for the purpose of simulating geomagnetic and interplanetary magnetic field environments. The facility includes a three axis Braunbek coil system consisting of 12 loops, 4 loops on each of the three orthogonal axes; a remote Earth field sensing magnetometer and servo controller; and a remote power control and instrumentation building. The inner coils of the Braunbek system are 42-foot in diameter with a 10-foot by 10-foot opening through the outer coils to accommodate spacecraft access into the test volume. The physical size and precision of the facility are matched by only two other such facilities in the world. The facility was used extensively from the late 1960's until the early 1990's when the requirement for spacecraft level testing diminished. New NASA missions planned under the Living with a Star, Solar Terrestrial Probes, Explorer, and New Millennium Programs include precision, high-resolution magnetometers to obtain magnetic field data that is critical to fulfilling their scientific mission. It is highly likely that future Lunar and Martian exploration missions will also use precision magnetometers to conduct geophysical magnetic surveys. To ensure the success of these missions, ground testing using a magnetic test facility such as the GSFC SMTF will be required. This paper describes the history of the facility, the future mission requirements that have renewed the need for spacecraft level magnetic testing, and the plans for restoring the facility to be capable of performing to its original design specifications.

  3. Atmospheric Radiation Measurement Madden-Julian Oscillation Investigation Experiment Field Campaign Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Long, Chuck

    2016-07-01

    Every 30–90 days during the Northern Hemisphere winter, the equatorial tropical atmosphere experiences pulses of extraordinarily strong deep convection and rainfall. This phenomenon is referred to as the Madden–Julian Oscillation, or MJO, named after the scientists who identified this cycle. The MJO significantly affects weather and rainfall patterns around the world (Zhang 2013). To improve predictions of the MJO—especially about how it forms and evolves throughout its lifecycle—an international group of scientists collected an unprecedented set of observations from the Indian Ocean and western Pacific region from October 2011 through March 2012 through several coordinated efforts. The coordinated field campaignsmore » captured six distinct MJO cycles in the Indian Ocean. The rich set of observations capturing several MJO events from these efforts will be used for many years to study the physics of the MJO. Here we highlight early research results using data from the Atmospheric Radiation Measurement (ARM) Madden-Julian Oscillation Investigation Experiment (AMIE), sponsored by the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility.« less

  4. Radio Observations of Elongated Pulsar Wind Nebulae

    NASA Astrophysics Data System (ADS)

    Ng, Stephen C.-Y.

    2015-08-01

    The majority of pulsars' rotational energy is carried away by relativistic winds, which are energetic particles accelerated in the magnetosphere. The confinement of the winds by the ambient medium result in synchrotron bubbles with broad-band emission, which are commonly referred to as pulsar wind nebulae (PWNe). Due to long synchrotron cooling time, a radio PWN reflects the integrated history of the system, complementing information obtained from the X-ray and higher energy bands. In addition, radio polarization measurements can offer a powerful probe of the PWN magnetic field structure. Altogether these can reveal the physical conditions and evolutionary history of a system.I report on preliminary results from high-resolution radio observations of PWNe associated with G327.1-1.1, PSRs J1015-5719, B1509-58, and J1549-4848 taken with the Australia Telescope Compact Array (ATCA). Their magnetic field structure and multiwavelength comparison with other observations are discussed.This work is supported by a ECS grant of the Hong Kong Government under HKU 709713P. The Australia Telescope is funded by the Commonwealth of Australia for operation as a National Facility managed by CSIRO.

  5. SD46 Facilities and Capabilities

    NASA Technical Reports Server (NTRS)

    Ramachandran, N.; Curreri, Peter A. (Technical Monitor)

    2002-01-01

    The displays for the Materials Conference presents some of the facilities and capabilities in SD46 that can be useful to a prospective researcher from University, Academia or other government labs. Several of these already have associated personnel as principal and co-investigators on NASA peer reviewed science investigations. 1. SCN purification facility 2. ESL facility 3. Static and Dynamic magnetic field facility 4. Microanalysis facility 5. MSG Investigation - PFMI 6. Thermo physical Properties Measurement Capabilities.

  6. Performance of a 12-coil superconducting bumpy torus magnet facility

    NASA Technical Reports Server (NTRS)

    Roth, J. R.; Holmes, A. D.; Keller, T. A.; Krawczonek, W. M.

    1972-01-01

    The bumpy torus facility consists of 12 superconducting coils, each 19 cm i.d. and capable of 3.0 teslas on their axes. The coils are equally spaced around a toroidal array with a major diameter of 1.52 m, and are mounted with the major axis of the torus vertical in a single vacuum tank 2.6 m in diameter. Final shakedown tests of the facility mapped out its magnetic, cryogenic, vacuum, mechanical, and electrical performance. The facility is now ready for use as a plasma physics research facility. A maximum magnetic field on the magnetic axis of 3.23 teslas was held for a period of more than sixty minutes without a coil normalcy. The design field was 3.00 teslas. The steady-state liquid helium boil-off rate was 87 liters per hour of liquid helium without the coils charged. The coil array was stable when subjected to an impulsive loading, even with the magnets fully charged. When the coils were charged to a maximum magnetic field of 3.35 teslas, the system was driven normal without damage.

  7. Criticality Safety Evaluation for Small Sample Preparation and Non-Destructive Assay (NDA) Operations in Wing 7 Basement of the CMR Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kunkle, Paige Elizabeth; Zhang, Ning

    Nuclear Criticality Safety (NCS) has reviewed the fissionable material small sample preparation and NDA operations in Wing 7 Basement of the CMR Facility. This is a Level-1 evaluation conducted in accordance with NCS-AP-004 [Reference 1], formerly NCS-GUIDE-01, and the guidance set forth on use of the Standard Criticality Safety Requirements (SCSRs) [Reference 2]. As stated in Reference 2, the criticality safety evaluation consists of both the SCSR CSED and the SCSR Application CSED. The SCSR CSED is a Level-3 CSED [Reference 3]. This Level-1 CSED is the SCSR Application CSED. This SCSR Application (Level-1) evaluation does not derive controls, itmore » simply applies controls derived from the SCSR CSED (Level-3) for the application of operations conducted here. The controls derived in the SCSR CSED (Level-3) were evaluated via the process described in Section 6.6.5 of SD-130 (also reproduced in Section 4.3.5 of NCS-AP-004 [Reference 1]) and were determined to not meet the requirements for consideration of elevation into the safety basis documentation for CMR. According to the guidance set forth on use of the SCSRs [Reference 2], the SCSR CSED (Level-3) is also applicable to the CMR Facility because the process and the normal and credible abnormal conditions in question are bounded by those that are described in the SCSR CSED. The controls derived in the SCSR CSED include allowances for solid materials and solution operations. Based on the operations conducted at this location, there are less-than-accountable (LTA) amounts of 233U. Based on the evaluation documented herein, the normal and credible abnormal conditions that might arise during the execution of this process will remain subcritical with the following recommended controls.« less

  8. High throughput field plant phenotyping facility at University of Nebraska-Lincoln and the first year experience

    NASA Astrophysics Data System (ADS)

    Ge, Y.; Bai, G.; Irmak, S.; Awada, T.; Stoerger, V.; Graef, G.; Scoby, D.; Schnable, J.

    2017-12-01

    University of Nebraska - Lincoln's high throughput field plant phenotyping facility is a cable robot based system built on a 1-ac field. The sensor platform is tethered with eight cables via four poles at the corners of the field for its precise control and positioning. The sensor modules on the platform include a 4-band RGB-NIR camera, a thermal infrared camera, a 3D LiDAR, VNIR spectrometers, and environmental sensors. These sensors are used to collect multifaceted physiological, structural and chemical properties of plants from the field plots. A subsurface drip irrigation system is established in this field which allows a controlled amount of water and fertilizers to be delivered to individual plots. An extensive soil moisture sensor network is also established to monitor soil water status, and serve as a feedback loop for irrigation scheduling. In the first year of operation, the field is planted maize and soybean. Weekly ground truth data were collected from the plots to validate image and sensor data from the phenotyping system. This presentation will provide an overview of this state-of-the-art field plant phenotyping facility, and present preliminary data from the first year operation of the system.

  9. Towards elimination of mother-to-child transmission of HIV: performance of different models of care for initiating lifelong antiretroviral therapy for pregnant women in Malawi (Option B+)

    PubMed Central

    van Lettow, Monique; Bedell, Richard; Mayuni, Isabell; Mateyu, Gabriel; Landes, Megan; Chan, Adrienne K; van Schoor, Vanessa; Beyene, Teferi; Harries, Anthony D; Chu, Stephen; Mganga, Andrew; van Oosterhout, Joep J

    2014-01-01

    Introduction Malawi introduced a new strategy to improve the effectiveness of prevention of mother-to-child HIV transmission (PMTCT), the Option B+ strategy. We aimed to (i) describe how Option B+ is provided in health facilities in the South East Zone in Malawi, identifying the diverse approaches to service organization (the “model of care”) and (ii) explore associations between the “model of care” and health facility–level uptake and retention rates for pregnant women identified as HIV-positive at antenatal (ANC) clinics. Methods A health facility survey was conducted in all facilities providing PMTCT/antiretroviral therapy (ART) services in six of Malawi's 28 districts to describe and compare Option B+ service delivery models. Associations of identified models with program performance were explored using facility cohort reports. Results Among 141 health facilities, four “models of care” were identified: A) facilities where newly identified HIV-positive women are initiated and followed on ART at the ANC clinic until delivery; B) facilities where newly identified HIV-positive women receive only the first dose of ART at the ANC clinic, and are referred to the ART clinic for follow-up; C) facilities where newly identified HIV-positive women are referred from ANC to the ART clinic for initiation and follow-up of ART; and D) facilities serving as ART referral sites (not providing ANC). The proportion of women tested for HIV during ANC was highest in facilities applying Model A and lowest in facilities applying Model B. The highest retention rates were reported in Model C and D facilities and lowest in Model B facilities. In multivariable analyses, health facility factors independently associated with uptake of HIV testing and counselling (HTC) in ANC were number of women per HTC counsellor, HIV test kit availability, and the “model of care” applied; factors independently associated with ART retention were district location, patient volume and the “model of care” applied. Conclusions A large variety exists in the way health facilities have integrated PMTCT Option B+ care into routine service delivery. This study showed that the “model of care” chosen is associated with uptake of HIV testing in ANC and retention in care on ART. Further patient-level research is needed to guide policy recommendations. PMID:25079437

  10. Naval Research Laboratory Major Facilities 2008

    DTIC Science & Technology

    2008-10-01

    Development Laboratory • Secure Supercomputing Facility • CBD/Tilghman Island IR Field Evaluation Facility • Ultra-Short-Pulse Laser Effects Research...EMI Test Facility • Proximity Operations Testbed GENERAL INFORMATION • Maps EX EC U TI V E D IR EC TO RA TE Code 1100 – Institute for Nanoscience...facility: atomic force microscope (AFM); benchtop transmission electron microscope (TEM); cascade probe station; critical point dryer ; dual beam focused

  11. Reference Mission Operational Analysis Document (RMOAD) for the Life Sciences Research Facilities

    NASA Technical Reports Server (NTRS)

    1987-01-01

    The space station will be constructed during the next decade as an orbiting, low-gravity, permanent facility. The facility will provide a multitude of research opportunities for many different users. The pressurized research laboratory will allow life scientists to study the effects of long-term exposure to microgravity on humans, animals, and plants. The results of these studies will increase our understanding of this foreign environment on basic life processes and ensure the safety of man's long-term presence in space. This document establishes initial operational requirements for the use of the Life Sciences Research Facility (LSRF) during its construction.

  12. Modified electrical survey for effective leakage detection at concrete hydraulic facilities

    NASA Astrophysics Data System (ADS)

    Lee, Bomi; Oh, Seokhoon

    2018-02-01

    Three original electrode arrays for the effective leakage detection of concrete hydraulic facilities through electrical resistivity surveys are proposed: 'cross-potential', 'direct-potential' and modified tomography-like arrays. The main differences with respect to the commonly used arrays are that the current line-sources are separated from potential pole lines and floated upon the water. The potential pole lines are located directly next to the facility in order to obtain intuitive data and useful interpretations of the internal conditions of the hydraulic facility. This modified configuration of the array clearly displays the horizontal variation of the electrical field around the damaged zones of the concrete hydraulic facility, and any anomalous regions that might be found between potential poles placed across the facilities. In order to facilitate the interpretation of these modified electrical surveys, a new and creative way of presenting the measurements is also proposed and an inversion approach is provided for the modified tomography-like array. A numerical modeling and two field tests were performed to verify these new arrays and interpretation methods. The cross and direct potential array implied an ability to detect small variations of the potential field near the measurement poles. The proposed array showed the overall potential distribution across the hydraulic facility which may be used to assist in the search of trouble zones within the structure, in combination with the traditional electrical resistivity array.

  13. The National Transonic Facility: A Research Retrospective

    NASA Technical Reports Server (NTRS)

    Wahls, R. A.

    2001-01-01

    An overview of the National Transonic Facility (NTF) from a research utilization perspective is provided. The facility was born in the 1970s from an internationally recognized need for a high Reynolds number test capability based on previous experiences with preflight predictions of aerodynamic characteristics and an anticipated need in support of research and development for future aerospace vehicle systems. Selection of the cryogenic concept to meet the need, unique capabilities of the facility, and the eventual research utilization of the facility are discussed. The primary purpose of the paper is to expose the range of investigations that have used the NTF since being declared operational in late 1984; limited research results are included, though many more can be found in the references.

  14. PREFACE: 17th Pan-American Synchrotron Radiation Instrumentation Conference SRI2013

    NASA Astrophysics Data System (ADS)

    Williams, Gwyn P.; Revesz, Peter; Arp, Uwe

    2014-03-01

    These proceedings are a collection of the articles presented at the seventeenth Pan-American Synchrotron Radiation Instrumentation Conference SRI2013, held on the campus of the National Institute of Standards and Technology (NIST), located in Gaithersburg, Maryland, United States of America, 19-21 June, 2013. SRI2013 was jointly hosted by the Cornell University Cornell High Energy Synchrotron Source (CHESS), the Thomas Jefferson National Accelerator Facility (Jefferson Lab), and the Synchrotron Ultraviolet Radiation Facility (SURF III) at NIST. This meeting's focus was clearly on instrumentation, thus fulfilling the intent of this SRI meeting series, which was initiated at NIST, then the National Bureau of Standards (NBS), in 1979. SRI2013 hosted more than 150 delegates, despite the new US governmental travel restrictions. This proceedings series aims to be an essential reference work for practitioners in the field. It primarily documents the evolution and development of techniques, but also recent scientific advances, that were presented during the two and a half days of the conference. We are extremely thankful to all the authors who contributed to making these proceedings a volume of reference as well as to the reviewers for their careful reading and constructive recommendations for improving the articles. Great thanks go to Robert Dragoset at NIST, for creating and maintaining the conference website and generating the conference logo. We are also thankful for the excellent support we received from the Conference Program at NIST, especially Kathy Kilmer and Angela Ellis. And we would like to dedicate these proceedings to the memory of Kathy Kilmer, who passed away on 15 October, 2013. NIST will not be the same without her. The Co-Editors: Uwe Arp (SURF/NIST) Peter Reversz (CHESS) Gwyn P Williams (Jefferson Lab)

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Owen, P. T.; Webb, J. R.; Knox, N. P.

    The 664 abstracted references on environmental restoration, nuclear facility decommissioning, uranium mill tailings management, and site remedial actions constitute the twelfth in a series of reports prepared annually for the US Department of Energy Remedial Action Programs. Citations to foreign and domestic literature of all types -- technical reports, progress reports, journal articles, symposia proceedings, theses, books, patents, legislation, and research project descriptions -- have been included. The bibliography contains scientific, technical, economic, regulatory, and legal information pertinent to the US Department of Energy Remedial Action Programs. Major sections are (1) Decontamination and Decommissioning Program, (2) Nuclear Facilities Decommissioning, (3)more » Formerly Utilized Sites Remedial Action Program, (4) Facilities Contaminated with Naturally Occurring Radionuclides, (5) Uranium Mill Tailings Remedial Action Program, (6) Uranium Mill Tailings Management, (7) Technical Measurements Center, and (8) Environmental Restoration Program. Within these categories, references are arranged alphabetically by first author. Those references having no individual author are listed by corporate affiliation or by publication title. Indexes are provided for author, corporate affiliation, title word, publication description, geographic location, subject category, and key word. This report is a product of the Remedial Action Program Information Center (RAPIC), which selects, analyzes, and disseminates information on environmental restoration and remedial actions. RAPIC staff and resources are available to meet a variety of information needs. Contact the center at FTS 624-7764 or (615) 574-7764.« less

  16. Configurable UUV Sensor Network II

    DTIC Science & Technology

    2017-12-13

    the South Florida Ocean Test Facility (SFOMF). A larger 3”-diameter ball-shaped electric field sensor was developed and fabricated. A pre -amplifier...magnetic field sensors, and tested at the South Florida Ocean Test Facility (SFOMF). A larger 3”-diameter ball-shaped electric field sensor was developed...and fabricated. Testing of the 3”-diameter ball-shaped sensor at UI showed a noise floor of IpV/m RMS in the frequency band 0.02-20 Hz. UUV

  17. Position-dependent performance of copper phthalocyanine based field-effect transistors by gold nanoparticles modification.

    PubMed

    Luo, Xiao; Li, Yao; Lv, Wenli; Zhao, Feiyu; Sun, Lei; Peng, Yingquan; Wen, Zhanwei; Zhong, Junkang; Zhang, Jianping

    2015-01-21

    A facile fabrication and characteristics of copper phthalocyanine (CuPc)-based organic field-effect transistor (OFET) using the gold nanoparticles (Au NPs) modification is reported, thereby achieving highly improved performance. The effect of Au NPs located at three different positions, that is, at the SiO2/CuPc interface (device B), embedding in the middle of CuPc layer (device C), and on the top of CuPc layer (device D), is investigated, and the results show that device D has the best performance. Compared with the device without Au NPs (reference device A), device D displays an improvement of field-effect mobility (μ(sat)) from 1.65 × 10(-3) to 5.51 × 10(-3) cm(2) V(-1) s(-1), and threshold voltage decreases from -23.24 to -16.12 V. Therefore, a strategy for the performance improvement of the CuPc-based OFET with large field-effect mobility and saturation drain current is developed, on the basis of the concept of nanoscale Au modification. The model of an additional electron transport channel formation by FET operation at the Au NPs/CuPc interface is therefore proposed to explain the observed performance improvement. Optimum CuPc thickness is confirmed to be about 50 nm in the present study. The device-to-device uniformity and time stability are discussed for future application.

  18. 28 CFR Appendix C to Part 61 - Immigration and Naturalization Service Procedures Relating to the Implementation of the National...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... INS facility which would have a significant impact upon the environment. (b) Construction of a new... have a significant impact upon the environment. (Reference: § 1507.3(b)(2)(i)—CEQ Regulations.) 10... significantly impact upon the environment. (b) Increase or decrease in population of a facility within its...

  19. 40 CFR 60.1185 - What types of operator certification must the chief facility operator and shift supervisor obtain...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    .... (c) Each chief facility operator and shift supervisor must take one of three actions: (1) Obtain a... in your State. (2) Schedule a full certification exam with the American Society of Mechanical Engineers (QRO-1-1994) (incorporated by reference in § 60.17(h)(1)). (3) Schedule a full certification exam...

  20. 40 CFR 60.1675 - What types of operator certification must the chief facility operator and shift supervisor obtain...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... after they are hired to work at the municipal waste combustion unit. (c) Each chief facility operator... certification exam with the American Society of Mechanical Engineers (QRO-1-1994) (incorporated by reference in § 60.17(h)(1)). (3) Schedule a full certification exam with your State certification program. (d) The...

  1. Hierarchical 3D ordered meso-/macroporous metal-organic framework produced through a facile template-free self-assembly

    NASA Astrophysics Data System (ADS)

    Yang, Xiaoli; Wu, Suilan; Wang, Panhao; Yang, Lin

    2018-02-01

    The synthesis of well-ordered hierarchical metal-organic frameworks (MOFs) in an efficient manner is a great challenge. Here, a 3D regular ordered meso-/macroporous MOF of Cu-TATAB (referred to as MM-MOF) was synthesized through a facile template-free self-assembly process with pore sizes of 31 nm and 119 nm.

  2. Space Station Biological Research Project: Reference Experiment Book

    NASA Technical Reports Server (NTRS)

    Johnson, Catherine (Editor); Wade, Charles (Editor)

    1996-01-01

    The Space Station Biological Research Project (SSBRP), which is the combined efforts of the Centrifuge Facility (CF) and the Gravitational Biology Facility (GBF), is responsible for the development of life sciences hardware to be used on the International Space Station to support cell, developmental, and plant biology research. The SSBRP Reference Experiment Book was developed to use as a tool for guiding this development effort. The reference experiments characterize the research interests of the international scientific community and serve to identify the hardware capabilities and support equipment needed to support such research. The reference experiments also serve as a tool for understanding the operational aspects of conducting research on board the Space Station. This material was generated by the science community by way of their responses to reference experiment solicitation packages sent to them by SSBRP scientists. The solicitation process was executed in two phases. The first phase was completed in February of 1992 and the second phase completed in November of 1995. Representing these phases, the document is subdivided into a Section 1 and a Section 2. The reference experiments contained in this document are only representative microgravity experiments. They are not intended to define actual flight experiments. Ground and flight experiments will be selected through the formal NASA Research Announcement (NRA) and Announcement of Opportunity (AO) experiment solicitation, review, and selection process.

  3. Spherical Lu2O2S:Eu3+ micro/nano-structure: Controlled synthesis and luminescence properties

    NASA Astrophysics Data System (ADS)

    Zhang, Bowen; Zou, Haifeng; Dai, Yunzhi; Guan, Hongxia; Song, Yanhua; Zheng, Keyan; Zhou, Xiuqing; Shi, Zhan; Sheng, Ye

    2017-02-01

    Monodisperse and uniform Lu2O2S:Eu3+ luminescent spheres have been successfully synthesized through a facile hydrothermal method followed by a subsequent calcination process. The sizes of the spheres can be tuned in the range of 65 nm-295 nm by only changing the pH value of the system. It is indicated that the luminescence properties of the spherical phosphors were strongly influenced by size of the spheres. Such a size-sensitive luminescence property was interpreted from the structures of the spheres, including the degree of crystallinity, band gap energy, crystal field symmetry around Eu3+. We expected that this study not only can provide important information for size-controlled synthesis of spherical phosphors, but also can give a reference for exploration of size-dependent luminescence.

  4. Motion compensation and noise tolerance in phase-shifting digital in-line holography.

    PubMed

    Stenner, Michael D; Neifeld, Mark A

    2006-05-15

    We present a technique for phase-shifting digital in-line holography which compensates for lateral object motion. By collecting two frames of interference between object and reference fields with identical reference phase, one can estimate the lateral motion that occurred between frames using the cross-correlation. We also describe a very general linear framework for phase-shifting holographic reconstruction which minimizes additive white Gaussian noise (AWGN) for an arbitrary set of reference field amplitudes and phases. We analyze the technique's sensitivity to noise (AWGN, quantization, and shot), errors in the reference fields, errors in motion estimation, resolution, and depth of field. We also present experimental motion-compensated images achieving the expected resolution.

  5. Wake Survey of a Marine Current Turbine Under Steady Conditions

    NASA Astrophysics Data System (ADS)

    Lust, Ethan; Luznik, Luksa; Flack, Karen

    2016-11-01

    A submersible particle image velocimetry (PIV) system was used to study the wake of a horizontal axis marine current turbine. The turbine was tested in a large tow tank facility at the United States Naval Academy. The turbine is a 1/25th scale model of the U.S. National Renewable Energy Laboratory's Reference Model 1 (RM1) tidal turbine. It is a two-bladed turbine measuring 0.8 m in diameter and featuring a NACA 63-618 airfoil cross section. Separate wind tunnel testing has shown the foil section used on the turbine to be Reynolds number independent with respect to lift at the experimental parameters of tow carriage speed (Utow = 1 . 68 m/s) and tip speed ratio (TSR = 7). The wake survey was conducted over an area extending 0.25D forward of the turbine tip path to 2.0D aft, and to a depth of 1.0D beneath the turbine output shaft in the streamwise plane. Each field of view was approximately 30 cm by 30 cm, and each overlapped the adjacent fields of view by 5 cm. The entire flow field was then reconstructed into a single field of investigation. Results include streamwise and vertical ensemble average velocity fields averaged over approximately 1,000 realizations, as well as higher-order statistics. Turbine tip vortex centers were identified and plotted showing increasing aperiodicity with wake age. keywords: horizontal axis marine current turbine, particle image velocimetry, towing tank, wake survey

  6. BrainSnail: A dynamic information display system for the Sciences

    PubMed Central

    Telefont, Martin; Asaithambi, Asai

    2009-01-01

    Scientific reference management has become crucial in rapidly expanding fields of biology. Many of the reference management systems currently employed are reference centric and not object/process focused. BrainSnail is a reference management/knowledge representation application that tries to bridge disconnect between subject and reference in the fields of neuropharmacology, neuroanatomy and neurophysiology. BrainSnail has been developed with considering both individual researcher and research group efforts. PMID:19293992

  7. Comparison of Haemophilus parasuis reference strains and field isolates by using random amplified polymorphic DNA and protein profiles

    PubMed Central

    2012-01-01

    Background Haemophilus parasuis is the causative agent of Glässer’s disease and is a pathogen of swine in high-health status herds. Reports on serotyping of field strains from outbreaks describe that approximately 30% of them are nontypeable and therefore cannot be traced. Molecular typing methods have been used as alternatives to serotyping. This study was done to compare random amplified polymorphic DNA (RAPD) profiles and whole cell protein (WCP) lysate profiles as methods for distinguishing H. parasuis reference strains and field isolates. Results The DNA and WCP lysate profiles of 15 reference strains and 31 field isolates of H. parasuis were analyzed using the Dice and neighbor joining algorithms. The results revealed unique and reproducible DNA and protein profiles among the reference strains and field isolates studied. Simpson’s index of diversity showed significant discrimination between isolates when three 10mer primers were combined for the RAPD method and also when both the RAPD and WCP lysate typing methods were combined. Conclusions The RAPD profiles seen among the reference strains and field isolates did not appear to change over time which may reflect a lack of DNA mutations in the genes of the samples. The recent field isolates had different WCP lysate profiles than the reference strains, possibly because the number of passages of the type strains may affect their protein expression. PMID:22703293

  8. Atmospheric stability analysis over statically and dynamically rough surfaces

    NASA Astrophysics Data System (ADS)

    Maric, Emina; Metzger, Meredith; Singha, Arindam; Sadr, Reza

    2011-11-01

    The ratio of buoyancy flux to turbulent kinetic energy production in the atmospheric surface layer is investigated experimentally for air flow over two types of surfaces characterized by static and dynamic roughness. In this study, ``static'' refers to the time-invariant nature of naturally-occurring roughness over a mud/salt playa; while, ``dynamic'' refers to the behavior of water waves along an air-water interface. In both cases, time-resolved measurements of the momentum and heat fluxes were acquired from synchronized 3D sonic anemometers mounted on a vertical tower. Field campaigns were conducted at two sites, representing the ``statically'' and ``dynamically'' rough surfaces, respectively: (1) the SLTEST facility in Utah's western desert, and (2) the new Doha airport in Qatar under construction along the coast of the Persian Gulf. Note, at site 2, anemometers were located directly above the water by extension from a tower secured to the end of a 1 km-long pier. Comparisons of the Monin-Obukhov length, flux Richardson number, and gradient Richardson number are presented, and discussed in the context of the observed evolution of the turbulent spectra in response to diurnal variations of atmospheric stability. Supported by the Qatar National Research Fund.

  9. Nuclear facility decommissioning and site remedial actions: A selected bibliography, volume 9

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Owen, P.T.; Knox, N.P.; Michelson, D.C.

    1988-09-01

    The 604 abstracted references on nuclear facility decommissioning, uranium mill tailings management, and site remedial actions constitute the ninth in a series of reports prepared annually for the US Department of Energy's Remedial Action Programs. Foreign and domestic literature of all types--technical reports, progress reports, journal articles, symposia proceedings, theses, books, patents, legislation, and research project descriptions--has been included. The bibliography contains scientific, technical, economic, regulatory, and legal information pertinent to the US Department of Energy's remedial action programs. Major sections are (1) Surplus Facilities Management Program, (2) Nuclear Facilities Decommissioning, (3) Formerly Utilized Sites Remedial Action Program, (4) Facilitiesmore » Contaminated with Naturally Occurring Radionuclides, (5) Uranium Mill Tailings Remedial Action Program, (6) Uranium Mill Tailings Management, (7) Technical Measurements Center, and (8) General Remedial Action Program Studies. Subsections for sections 1, 2, 5, and 6 include: Design, Planning, and Regulations; Environmental Studies and Site Surveys; Health, Safety, and Biomedical Studies; Decontamination Studies; Dismantlement and Demolition; Site Stabilization and Reclamation; Waste Disposal; Remedial Action Experience; and General Studies. Within these categories, references are arranged alphabetically by first author. Those references having no individual author are listed by corporate affiliation or by publication description. Indexes are provided for author, corporate affiliation, title word, publication description, geographic location, and keywords. This report is a product of the Remedial Action Program Information Center (RAPIC), which selects and analyzes information on remedial actions and relevant radioactive waste management technologies. RAPIC staff and resources are available to meet a variety of information needs. Contact the center at (615) 576-0568 or FTS 626-0568.« less

  10. Stormwater Pollution Prevention Plan - TA-60 Material Recycling Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sandoval, Leonard Frank

    This Storm Water Pollution Prevention Plan (SWPPP) was developed in accordance with the provisions of the Clean Water Act (33 U.S.C. §§1251 et seq., as amended), and the Multi-Sector General Permit for Storm Water Discharges Associated with Industrial Activity (U.S. EPA, June 2015) issued by the U.S. Environmental Protection Agency (EPA) for the National Pollutant Discharge Elimination System (NPDES) and using the industry specific permit requirements for Sector P-Land Transportation and Warehousing as a guide. This SWPPP applies to discharges of stormwater from the operational areas of the TA- 60 Material Recycling Facility at Los Alamos National Laboratory. Los Alamosmore » National Laboratory (also referred to as LANL or the “Laboratory”) is owned by the Department of Energy (DOE), and is operated by Los Alamos National Security, LLC (LANS). Throughout this document, the term “facility” refers to the TA-60 Material Recycling Facility. The current permit expires at midnight on June 4, 2020.« less

  11. 40 CFR 60.547 - Test methods and procedures.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... materials. In the event of dispute, Method 24 shall be the reference method. For Method 24, the cement or... sample will be representative of the material as applied in the affected facility. (2) Method 25 as the... by the Administrator. (3) Method 2, 2A, 2C, or 2D, as appropriate, as the reference method for...

  12. 40 CFR 60.547 - Test methods and procedures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... materials. In the event of dispute, Method 24 shall be the reference method. For Method 24, the cement or... sample will be representative of the material as applied in the affected facility. (2) Method 25 as the... by the Administrator. (3) Method 2, 2A, 2C, or 2D, as appropriate, as the reference method for...

  13. 40 CFR 60.547 - Test methods and procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... materials. In the event of dispute, Method 24 shall be the reference method. For Method 24, the cement or... sample will be representative of the material as applied in the affected facility. (2) Method 25 as the... by the Administrator. (3) Method 2, 2A, 2C, or 2D, as appropriate, as the reference method for...

  14. Equine Science. Instructor Guide [and] Student Reference. Volume 27, Number 4 [and] Volume 27, Number 5.

    ERIC Educational Resources Information Center

    Leffert, Kenneth L.; And Others

    This instructor guide and the corresponding student reference contain 10 lessons to enhance an Agricultural Science I course for grade 9. The lessons cover the following topics: introduction, psychology and handling, conformation and selection, genetics and reproduction, herd health, hoof care, nutrition, equipment and facilities, handling horses,…

  15. Improving district facility readiness: a 12-month evaluation of a data-driven health systems strengthening intervention in rural Rwanda.

    PubMed

    Iyer, Hari S; Kamanzi, Emmanuel; Mugunga, Jean Claude; Finnegan, Karen; Uwingabiye, Alice; Shyaka, Edward; Niyonzima, Saleh; Hirschhorn, Lisa R; Drobac, Peter C

    2015-01-01

    While health systems strengthening (HSS) interventions are recommended by global health policy experts to improve population health in resource-limited settings, few examples exist of evaluations of HSS interventions conducted at the district level. In 2009, a partnership between Partners In Health (PIH), a non-governmental organization, and the Rwandan Ministry of Health (RMOH) was provided funds to implement and evaluate a district-level HSS intervention in two rural districts of Rwanda. The partnership provided limited funds to 14 health centers for targeted systems support in 2010; six others received support prior to the intervention (reference). RMOH health systems norms were mapped across the WHO HSS framework, scored from 0 to 10 and incorporated into a rapid survey assessing 11 domains of facility readiness. Stakeholder meetings allowed partnership leaders to review results, set priorities, and allocate resources. Investments included salary support, infrastructure improvements, medical equipment, and social support for patients. We compared facility domain scores from the start of the intervention to 12 months and tested for correlation between change in score and change in funding allocation to assess equity in our approach. We found significant improvements among intervention facilities from baseline to 12 months across several domains [infrastructure (+4, p=0.0001), clinical services (+1.2, p=0.03), infection and sanitation control (+0.6, p=0.03), medical equipment (+1.0, p=0.02), information use (+2, p=0.002)]. Composite score across domains improved from 6.2 at baseline to 7.4 at 12 months (p=0.002). Across facilities, 50% had composite scores greater than the average score among reference facilities (7.4) at 12 months compared to none at baseline. Rapid facility surveys, stakeholder engagement, and information feedback can be used for gap analysis and resource allocation. This approach can achieve effective use of limited resources, improve facility readiness, and ensure consistency of facility capacity to provide quality care at the district level.

  16. Improving district facility readiness: a 12-month evaluation of a data-driven health systems strengthening intervention in rural Rwanda

    PubMed Central

    Iyer, Hari S.; Kamanzi, Emmanuel; Mugunga, Jean Claude; Finnegan, Karen; Uwingabiye, Alice; Shyaka, Edward; Niyonzima, Saleh; Hirschhorn, Lisa R.; Drobac, Peter C.

    2015-01-01

    Background While health systems strengthening (HSS) interventions are recommended by global health policy experts to improve population health in resource-limited settings, few examples exist of evaluations of HSS interventions conducted at the district level. In 2009, a partnership between Partners In Health (PIH), a non-governmental organization, and the Rwandan Ministry of Health (RMOH) was provided funds to implement and evaluate a district-level HSS intervention in two rural districts of Rwanda. Design The partnership provided limited funds to 14 health centers for targeted systems support in 2010; six others received support prior to the intervention (reference). RMOH health systems norms were mapped across the WHO HSS framework, scored from 0 to 10 and incorporated into a rapid survey assessing 11 domains of facility readiness. Stakeholder meetings allowed partnership leaders to review results, set priorities, and allocate resources. Investments included salary support, infrastructure improvements, medical equipment, and social support for patients. We compared facility domain scores from the start of the intervention to 12 months and tested for correlation between change in score and change in funding allocation to assess equity in our approach. Results We found significant improvements among intervention facilities from baseline to 12 months across several domains [infrastructure (+4, p=0.0001), clinical services (+1.2, p=0.03), infection and sanitation control (+0.6, p=0.03), medical equipment (+1.0, p=0.02), information use (+2, p=0.002)]. Composite score across domains improved from 6.2 at baseline to 7.4 at 12 months (p=0.002). Across facilities, 50% had composite scores greater than the average score among reference facilities (7.4) at 12 months compared to none at baseline. Conclusions Rapid facility surveys, stakeholder engagement, and information feedback can be used for gap analysis and resource allocation. This approach can achieve effective use of limited resources, improve facility readiness, and ensure consistency of facility capacity to provide quality care at the district level. PMID:26140729

  17. Characterization of airborne and bulk particulate from iron and steel manufacturing facilities.

    PubMed

    Machemer, Steven D

    2004-01-15

    Characterization of airborne and bulk particulate material from iron and steel manufacturing facilities, commonly referred to as kish, indicated graphite flakes and graphite flakes associated with spherical iron oxide particles were unique particle characteristics useful in identifying particle emissions from iron and steel manufacturing. Characterization of airborne particulate material collected in receptor areas was consistent with multiple atmospheric release events of kish particles from the local iron and steel facilities into neighboring residential areas. Kish particles deposited in nearby residential areas included an abundance of graphite flakes, tens of micrometers to millimeters in size, and spherical iron oxide particles, submicrometer to tens of micrometers in size. Bulk kish from local iron and steel facilities contained an abundance of similar particles. Approximately 60% of blast furnace kish by volume consisted of spherical iron oxide particles in the respirable size range. Basic oxygen furnace kish contained percent levels of strongly alkaline components such as calcium hydroxide. In addition, concentrations of respirable Mn in airborne particulate in residential areas and at local iron and steel facilities were approximately 1.6 and 53 times the inhalation reference concentration of 0.05 microg/m3 for chronic inhalation exposure of Mn, respectively. Thus, airborne release of kish may pose potential respirable particulate, corrosive, or toxic hazards for human health and/or a corrosive hazard for property and the environment.

  18. Field evaluations of the VD max approach for substantiation of a 25 kGy sterilization dose and its application to other preselected doses

    NASA Astrophysics Data System (ADS)

    Kowalski, John B.; Herring, Craig; Baryschpolec, Lisa; Reger, John; Patel, Jay; Feeney, Mary; Tallentire, Alan

    2002-08-01

    The International and European standards for radiation sterilization require evidence of the effectiveness of a minimum sterilization dose of 25 kGy but do not provide detailed guidance on how this evidence can be generated. An approach, designated VD max, has recently been described and computer evaluated to provide safe and unambiguous substantiation of a 25 kGy sterilization dose. The approach has been further developed into a practical method, which has been subjected to field evaluations at three manufacturing facilities which produce different types of medical devices. The three facilities each used a different overall evaluation strategy: Facility A used VD max for quarterly dose audits; Facility B compared VD max and Method 1 in side-by-side parallel experiments; and Facility C, a new facility at start-up, used VD max for initial substantiation of 25 kGy and subsequent quarterly dose audits. A common element at all three facilities was the use of 10 product units for irradiation in the verification dose experiment. The field evaluations of the VD max method were successful at all three facilities; they included many different types of medical devices/product families with a wide range of average bioburden and sample item portion values used in the verification dose experiments. Overall, around 500 verification dose experiments were performed and no failures were observed. In the side-by-side parallel experiments, the outcomes of the VD max experiments were consistent with the outcomes observed with Method 1. The VD max approach has been extended to sterilization doses >25 and <25 kGy; verification doses have been derived for sterilization doses of 15, 20, 30, and 35 kGy. Widespread application of the VD max method for doses other than 25 kGy must await controlled field evaluations and the development of appropriate specifications/standards.

  19. 137Cs Radiological risk estimation of NSD facility at Karawang site by using RESRAD onsite application: effect of cover thickness

    NASA Astrophysics Data System (ADS)

    Setiawan, B.; Prihastuti, S.; Moersidik, S. S.

    2018-02-01

    The operational of near surface disposal facility during waste packages loading activity into the facility, or in a monitoring activity around disposal facility at Karawang area is predicted to give a radiological risk to radiation workers. The thickness of disposal facility cover system affected the number of radiological risk of workers. Due to this reason, a radiological risk estimation needs to be considered. RESRAD onsite code is applied for this purpose by analyse the individual accepted dose and radiological risk data of radiation workers. The obtained results and then are compared with radiation protection reference in accordance with national regulation. In this case, the data from the experimental result of Karawang clay as host of disposal facility such as Kd value of 137Cs was used. Results showed that the thickness of the cover layer of disposal facility affected to the radiological risk which accepted by workers in a near surface disposal facility.

  20. Further assessment of houseflies (Musca domestica) as vectors for the mechanical transport and transmission of porcine reproductive and respiratory syndrome virus under field conditions.

    PubMed

    Pitkin, Andrea; Deen, John; Otake, Satoshi; Moon, Roger; Dee, Scott

    2009-04-01

    The purpose of this study was to evaluate the potential for houseflies (Musca domestica) to mechanically transport and transmit porcine reproductive and respiratory syndrome virus (PRRSV) between pig populations under controlled field conditions. The study employed swine housed in commercial livestock facilities and a release-recapture protocol involving marked (ochre-eyed) houseflies. To assess whether transport of PRRSV by insects occurred, ochre-eyed houseflies were released and collected from a facility housing an experimentally PRRSV-inoculated population of pigs (facility A) and collected from a neighboring facility located 120 m to the northwest that housed a naïve pig population (facility B). All samples were tested for PRRSV RNA by polymerase chain reaction (PCR). To assess transmission between the 2 populations, blood samples were collected from naïve pigs in facility B at designated intervals and tested by PCR. A total of 7 replicates were conducted. During 2 of 7 replicates (1 and 5), PCR-positive ochre-eyed houseflies were recovered in facility B and pigs in this facility became infected with PRRSV. Chi-squared analysis indicated that the presence of PRRSV in an insect sample was significantly (P = 0.0004) associated with infection of facility B pigs. Porcine reproductive and respiratory syndrome virus was not recovered from other reported routes of transmission during the study period, including air, fomites, and personnel. In conclusion, while an insufficient number of replicates were conducted to predict the frequency of the event, houseflies may pose some level of risk for the transport and transmission of PRRSV between pig populations under field conditions.

  1. Further assessment of houseflies (Musca domestica) as vectors for the mechanical transport and transmission of porcine reproductive and respiratory syndrome virus under field conditions

    PubMed Central

    Pitkin, Andrea; Deen, John; Otake, Satoshi; Moon, Roger; Dee, Scott

    2009-01-01

    The purpose of this study was to evaluate the potential for houseflies (Musca domestica) to mechanically transport and transmit porcine reproductive and respiratory syndrome virus (PRRSV) between pig populations under controlled field conditions. The study employed swine housed in commercial livestock facilities and a release-recapture protocol involving marked (ochre-eyed) houseflies. To assess whether transport of PRRSV by insects occurred, ochre-eyed houseflies were released and collected from a facility housing an experimentally PRRSV-inoculated population of pigs (facility A) and collected from a neighboring facility located 120 m to the northwest that housed a naïve pig population (facility B). All samples were tested for PRRSV RNA by polymerase chain reaction (PCR). To assess transmission between the 2 populations, blood samples were collected from naïve pigs in facility B at designated intervals and tested by PCR. A total of 7 replicates were conducted. During 2 of 7 replicates (1 and 5), PCR-positive ochre-eyed houseflies were recovered in facility B and pigs in this facility became infected with PRRSV. Chi-squared analysis indicated that the presence of PRRSV in an insect sample was significantly (P = 0.0004) associated with infection of facility B pigs. Porcine reproductive and respiratory syndrome virus was not recovered from other reported routes of transmission during the study period, including air, fomites, and personnel. In conclusion, while an insufficient number of replicates were conducted to predict the frequency of the event, houseflies may pose some level of risk for the transport and transmission of PRRSV between pig populations under field conditions. PMID:19436589

  2. The NHERI RAPID Facility: Enabling the Next-Generation of Natural Hazards Reconnaissance

    NASA Astrophysics Data System (ADS)

    Wartman, J.; Berman, J.; Olsen, M. J.; Irish, J. L.; Miles, S.; Gurley, K.; Lowes, L.; Bostrom, A.

    2017-12-01

    The NHERI post-disaster, rapid response research (or "RAPID") facility, headquartered at the University of Washington (UW), is a collaboration between UW, Oregon State University, Virginia Tech, and the University of Florida. The RAPID facility will enable natural hazard researchers to conduct next-generation quick response research through reliable acquisition and community sharing of high-quality, post-disaster data sets that will enable characterization of civil infrastructure performance under natural hazard loads, evaluation of the effectiveness of current and previous design methodologies, understanding of socio-economic dynamics, calibration of computational models used to predict civil infrastructure component and system response, and development of solutions for resilient communities. The facility will provide investigators with the hardware, software and support services needed to collect, process and assess perishable interdisciplinary data following extreme natural hazard events. Support to the natural hazards research community will be provided through training and educational activities, field deployment services, and by promoting public engagement with science and engineering. Specifically, the RAPID facility is undertaking the following strategic activities: (1) acquiring, maintaining, and operating state-of-the-art data collection equipment; (2) developing and supporting mobile applications to support interdisciplinary field reconnaissance; (3) providing advisory services and basic logistics support for research missions; (4) facilitating the systematic archiving, processing and visualization of acquired data in DesignSafe-CI; (5) training a broad user base through workshops and other activities; and (6) engaging the public through citizen science, as well as through community outreach and education. The facility commenced operations in September 2016 and will begin field deployments beginning in September 2018. This poster will provide an overview of the vision for the RAPID facility, the equipment that will be available for use, the facility's operations, and opportunities for user training and facility use.

  3. Changing the role of traditional birth attendants in Yirol West County, South Sudan.

    PubMed

    Wilunda, Calistus; Dall'Oglio, Giovanni; Scanagatta, Chiara; Segafredo, Giulia; Lukhele, Bhekumusa Wellington; Takahashi, Risa; Putoto, Giovanni; Manenti, Fabio; Betrán, Ana Pilar

    2017-01-01

    Effective from May 2014, community-based traditional birth attendants (TBAs) in Yirol West County, South Sudan, were directed to start referring all women in labour to health facilities for childbirth instead of assisting them in the villages. This study aimed to understand the degree of integration of TBAs in the health system, to reveal the factors influencing the integration, and to explore the perceived solutions to the challenges faced by TBAs. A qualitative study utilising 11 focus group discussions with TBAs, 6 focus group discussions with women, and 18 key informant interviews with members of village health committees, staff of health facilities, and staff of the County Health Department was conducted. Data were analysed using qualitative content analysis. The study found that many TBAs were referring women to health facilities for delivery, but some were still attending to deliveries at home. Facilitators of the adoption of the new role by TBAs were: acceptance of the new TBAs' role by the community, women and TBAs, perceptions about institutional childbirth and risks of home childbirth, personal commitment and motivation by some TBAs, a good working relationship between community-based TBAs and health facility staff, availability of incentives for women at health facilities, and training of TBAs. Challenges of integrating TBAs in the health system included, among others, communication problems between TBAs and health care facilities, delays in seeking care by women, insecurity, lack of materials and supplies for TBAs, health system constraints, insufficient incentives for TBAs, long distances to health facilities and transportation problems. This study has revealed encouraging developments in TBAs' integration in the formal health system in Yirol West. However, there is need to address the challenges faced by TBAs in assuming their new role in order to sustain the integration.

  4. Changing the role of traditional birth attendants in Yirol West County, South Sudan

    PubMed Central

    Dall’Oglio, Giovanni; Scanagatta, Chiara; Segafredo, Giulia; Lukhele, Bhekumusa Wellington; Takahashi, Risa; Putoto, Giovanni; Manenti, Fabio; Betrán, Ana Pilar

    2017-01-01

    Effective from May 2014, community-based traditional birth attendants (TBAs) in Yirol West County, South Sudan, were directed to start referring all women in labour to health facilities for childbirth instead of assisting them in the villages. This study aimed to understand the degree of integration of TBAs in the health system, to reveal the factors influencing the integration, and to explore the perceived solutions to the challenges faced by TBAs. A qualitative study utilising 11 focus group discussions with TBAs, 6 focus group discussions with women, and 18 key informant interviews with members of village health committees, staff of health facilities, and staff of the County Health Department was conducted. Data were analysed using qualitative content analysis. The study found that many TBAs were referring women to health facilities for delivery, but some were still attending to deliveries at home. Facilitators of the adoption of the new role by TBAs were: acceptance of the new TBAs’ role by the community, women and TBAs, perceptions about institutional childbirth and risks of home childbirth, personal commitment and motivation by some TBAs, a good working relationship between community-based TBAs and health facility staff, availability of incentives for women at health facilities, and training of TBAs. Challenges of integrating TBAs in the health system included, among others, communication problems between TBAs and health care facilities, delays in seeking care by women, insecurity, lack of materials and supplies for TBAs, health system constraints, insufficient incentives for TBAs, long distances to health facilities and transportation problems. This study has revealed encouraging developments in TBAs’ integration in the formal health system in Yirol West. However, there is need to address the challenges faced by TBAs in assuming their new role in order to sustain the integration. PMID:29095824

  5. Atmospheric Radiation Measurement Program Climate Research Facility Operations Quarterly Report. October 1 - December 31, 2009.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    D. L. Sisterson

    2010-01-12

    Individual raw data streams from instrumentation at the Atmospheric Radiation Measurement (ARM) Program Climate Research Facility (ACRF) fixed and mobile sites are collected and sent to the Data Management Facility (DMF) at Pacific Northwest National Laboratory (PNNL) for processing in near real-time. Raw and processed data are then sent approximately daily to the ACRF Archive, where they are made available to users. For each instrument, we calculate the ratio of the actual number of data records received daily at the Archive to the expected number of data records. The results are tabulated by (1) individual data stream, site, and monthmore » for the current year and (2) site and fiscal year (FY) dating back to 1998. The U.S. Department of Energy (DOE) requires national user facilities to report time-based operating data. The requirements concern the actual hours of operation (ACTUAL); the estimated maximum operation or uptime goal (OPSMAX), which accounts for planned downtime; and the VARIANCE [1 - (ACTUAL/OPSMAX)], which accounts for unplanned downtime. The OPSMAX time for the first quarter of FY 2010 for the North Slope Alaska (NSA) locale is 1,987.20 hours (0.90 x 2,208); for the Southern Great Plains (SGP) site is 2,097.60 hours (0.95 x 2,208); and for the Tropical Western Pacific (TWP) locale is 1,876.8 hours (0.85 x 2,208). The ARM Mobile Facility (AMF) deployment in Graciosa Island, the Azores, Portugal, continues; its OPSMAX time this quarter is 2,097.60 hours (0.95 x 2,208). The differences in OPSMAX performance reflect the complexity of local logistics and the frequency of extreme weather events. It is impractical to measure OPSMAX for each instrument or data stream. Data availability reported here refers to the average of the individual, continuous data streams that have been received by the Archive. Data not at the Archive are the result of downtime (scheduled or unplanned) of the individual instruments. Therefore, data availability is directly related to individual instrument uptime. Thus, the average percentage of data in the Archive represents the average percentage of the time (24 hours per day, 92 days for this quarter) the instruments were operating this quarter. The Site Access Request System is a web-based database used to track visitors to the fixed and mobile sites, all of which have facilities that can be visited. The NSA locale has the Barrow and Atqasuk sites. The SGP locale has historically had a central facility, 23 extended facilities, 4 boundary facilities, and 3 intermediate facilities. Beginning this quarter, the SGP began a transition to a smaller footprint (150 km x 150 km) by rearranging the original and new instrumentation made available through the American Recovery and Reinvestment Act (ARRA). The central facility and 4 extended facilities will remain, but there will be up to 16 surface new characterization facilities, 4 radar facilities, and 3 profiler facilities sited in the smaller domain. This new configuration will provide observations at scales more appropriate to current and future climate models. The TWP locale has the Manus, Nauru, and Darwin sites. These sites will also have expanded measurement capabilities with the addition of new instrumentation made available through ARRA funds. It is anticipated that the new instrumentation at all the fixed sites will be in place within the next 12 months. The AMF continues its 20-month deployment in Graciosa Island, Azores, Portugal, that started May 1, 2009. The AMF will also have additional observational capabilities within the next 12 months. Users can participate in field experiments at the sites and mobile facility, or they can participate remotely. Therefore, a variety of mechanisms are provided to users to access site information. Users who have immediate (real-time) needs for data access can request a research account on the local site data systems. This access is particularly useful to users for quick decisions in executing time-dependent activities associated with field campaigns at the fixed sites and mobile facility locations. The eight computers for the research accounts are located at the Barrow and Atqasuk sites; the SGP central facility; the TWP Manus, Nauru, and Darwin sites; the AMF; and the DMF at PNNL. However, users are warned that the data provided at the time of collection have not been fully screened for quality and therefore are not considered to be official ACRF data. Hence, these accounts are considered to be part of the facility activities associated with field campaign activities, and users are tracked. In addition, users who visit sites can connect their computer or instrument to an ACRF site data system network, which requires an on-site device account. Remote (off-site) users can also have remote access to any ACRF instrument or computer system at any ACRF site, which requires an off-site device account. These accounts are also managed and tracked.« less

  6. 40 CFR Table 1a to Subpart Ce of... - Emissions Limits for Small, Medium, and Large HMIWI at Designated Facilities as Defined in § 60...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) (grains per dry standard cubic foot (gr/dscf)) 115 (0.05) 69 (0.03) 34 (0.015) 3-run average (1-hour minimum sample time per run) EPA Reference Method 5 of appendix A-3 of part 60, or EPA Reference Method...-run average (1-hour minimum sample time per run) EPA Reference Method 10 or 10B of appendix A-4 of...

  7. 40 CFR Table 1a to Subpart Ce of... - Emissions Limits for Small, Medium, and Large HMIWI at Designated Facilities as Defined in § 60...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) (grains per dry standard cubic foot (gr/dscf)) 115 (0.05) 69 (0.03) 34 (0.015) 3-run average (1-hour minimum sample time per run) EPA Reference Method 5 of appendix A-3 of part 60, or EPA Reference Method...-run average (1-hour minimum sample time per run) EPA Reference Method 10 or 10B of appendix A-4 of...

  8. Referring physician satisfaction: toward a better understanding of hospital referrals.

    PubMed

    Ponzurick, T G; France, K R; Logar, C M

    1998-01-01

    Customer satisfaction literature has contributed significantly to the development of marketing strategies in the health-care arena. The research has led to the development of hospital-driven relationship marketing programs. This study examines the inclusion of referring physicians as partners in the hospital's relationship marketing program. In exploring this relationship, medical and hospital facility characteristics that referring physicians find important in making patient referrals to specialty care hospitals are identified and analyzed. The results lead to the development of strategic initiatives which hospital marketers should consider when developing relationship marketing programs designed to satisfy their referring physicians.

  9. Thermal-hydraulic analysis of the coil test facility for CFETR.

    PubMed

    Ren, Yong; Liu, Xiaogang; Li, Junjun; Wang, Zhaoliang; Qiu, Lilong; Du, Shijun; Li, Guoqiang; Gao, Xiang

    2016-01-01

    Performance test of the China Fusion Engineering Test Reactor (CFETR) central solenoid (CS) and toroidal field (TF) insert coils is of great importance to evaluate the CFETR magnet performance in relevant operation conditions. The superconducting magnet of the coil test facility for CFETR is being designed with the aim of providing a background magnetic field to test the CFETR CS insert and TF insert coils. The superconducting magnet consists of the inner module with Nb 3 Sn coil and the outer module with NbTi coil. The superconducting magnet is designed to have a maximum magnetic field of 12.59 T and a stored energy of 436.6 MJ. An active quench protection circuit and the positive temperature coefficient dump resistor were adopted to transfer the stored magnetic energy. The temperature margin behavior of the test facility for CFETR satisfies the design criteria. The quench analysis of the test facility shows that the cable temperature and the helium pressure inside the jacket are within the design criteria.

  10. Efficiency improvement of the investment and innovation activities in the transport facility construction field with public-private partnership involvement

    NASA Astrophysics Data System (ADS)

    Shibayeva, Marina; Serebryakova, Yelena; Shalnev, Oleg

    2017-10-01

    Growing demand to increase the investment volume in modernization and development projects for transport infrastructure define the urgency of the current study. The amount of private sector investments in the field is insufficient to implement the projects for road construction due to their significant capital intensity and long payoff period. The implementation of social significant infrastructure projects on the principles of public-private partnership is one of the key strategic directions of growth for transport facilities. The authors come up with a concept and methodology for modeling the investment and innovation activity in the transport facility construction. Furthermore, there is developed a model to find the balance between public and private sector investments in implementing construction projects for transport infrastructure with involvement of PPP (further - public-private partnership). The suggested concepts aim to improve the efficiency rate of the investment and innovation activity in the field of transport facility construction on the basis of public and private sectors collaboration.

  11. 40 CFR 792.45 - Test system supply facilities.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... maintaining algae and aquatic plants. (2) Facilities, as specified in the protocol, for plant growth, including but not limited to, greenhouses, growth chambers, light banks, and fields. (c) When appropriate... supplies shall be preserved by appropriate means. (b) When appropriate, plant supply facilities shall be...

  12. 40 CFR 792.45 - Test system supply facilities.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... maintaining algae and aquatic plants. (2) Facilities, as specified in the protocol, for plant growth, including but not limited to, greenhouses, growth chambers, light banks, and fields. (c) When appropriate... supplies shall be preserved by appropriate means. (b) When appropriate, plant supply facilities shall be...

  13. 40 CFR 792.45 - Test system supply facilities.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... maintaining algae and aquatic plants. (2) Facilities, as specified in the protocol, for plant growth, including but not limited to, greenhouses, growth chambers, light banks, and fields. (c) When appropriate... supplies shall be preserved by appropriate means. (b) When appropriate, plant supply facilities shall be...

  14. Sustainable Facility Development: Perceived Benefits and Challenges

    ERIC Educational Resources Information Center

    Stinnett, Brad; Gibson, Fred

    2016-01-01

    Purpose: The purpose of this paper is to assess the perceived benefits and challenges of implementing sustainable initiatives in collegiate recreational sports facilities. Additionally, this paper intends to contribute to the evolving field of facility sustainability in higher education. Design/methodology/approach The design included qualitative…

  15. Alignment system for SGII-Up laser facility

    NASA Astrophysics Data System (ADS)

    Gao, Yanqi; Cui, Yong; Li, Hong; Gong, Lei; Lin, Qiang; Liu, Daizhong; Zhu, Baoqiang; Ma, Weixin; Zhu, Jian; Lin, Zunqi

    2018-03-01

    The SGII-Up laser facility in Shanghai is one of the most important high-power laser facilities in China. It is designed to obtain 24 kJ (3ω) of energy with a square pulse of 3 ns using eight laser beams (two bundles). To satisfy the requirements for the safety, efficiency, and quality, an alignment system is developed for this facility. This alignment system can perform automatic alignment of the preamplifier system, main amplifier system, and harmonic conversion system within 30 min before every shot during the routine operation of the facility. In this article, an overview of the alignment system is first presented. Then, its alignment characteristics are discussed, along with the alignment process. Finally, experimental results, including the alignment results and the facility performance, are reported. The results show that the far-field beam pointing alignment accuracy is better than 3 μrad, and the alignment error of the near-field beam centering is no larger than 1 mm. These satisfy the design requirements very well.

  16. A control system of a mini survey facility for photometric monitoring

    NASA Astrophysics Data System (ADS)

    Tsutsui, Hironori; Yanagisawa, Kenshi; Izumiura, Hideyuki; Shimizu, Yasuhiro; Hanaue, Takumi; Ita, Yoshifusa; Ichikawa, Takashi; Komiyama, Takahiro

    2016-08-01

    We have built a control system for a mini survey facility dedicated to photometric monitoring of nearby bright (K<5) stars in the near-infrared region. The facility comprises a 4-m-diameter rotating dome and a small (30-mm aperture) wide-field (5 × 5 sq. deg. field of view) infrared (1.0-2.5 microns) camera on an equatorial fork mount, as well as power sources and other associated equipment. All the components other than the camera are controlled by microcomputerbased I/O boards that were developed in-house and are in many of the open-use instruments in our observatory. We present the specifications and configuration of the facility hardware, as well as the structure of its control software.

  17. Site Environmental Report for Calendar Year 2005. DOE Operations at The Boeing Company, Santa Susana Field Laboratory, Area IV

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2006-09-30

    This annual report describes the environmental monitoring programs related to the Department of Energy’s (DOE) activities at the Santa Susana Field Laboratory (SSFL) facility located in Ventura County, California during 2005. Part of the SSFL facility, known as Area IV, had been used for DOE’s activities since the 1950s. A broad range of energy related research and development (R&D) projects, including nuclear technologies projects, was conducted at the site. All the nuclear R&D operations in Area IV ceased in 1988. Current efforts are directed toward decontamination and decommissioning (D&D) of the former nuclear facilities and closure of facilities used formore » liquid metal research.« less

  18. Feasibility and Effectiveness of a Peer Referral Incentive Intervention to Promote Male Circumcision Uptake in Zambia

    PubMed Central

    Bolton, Carolyn; Lyabola, Lane-Lee; Phiri, Gabriel; Samona, Alick; Kaonga, Albert; Thirumurthy, Harsha

    2016-01-01

    Background: Medical male circumcision is a promising HIV prevention tool in countries with generalized HIV epidemics, but demand creation interventions are needed to support scale-up. We piloted a peer referral intervention in which circumcision clients were offered incentives for referring their peers for circumcision. Methods: The intervention was implemented between June 2014 and February 2015 in 6 randomly selected health facilities in Southern Province, Zambia. For the first 5 months, circumcision clients ≥18 years of age were given referral vouchers that allowed them to refer up to 5 peers for circumcision within a 3-month period. An incentive of US$2 was offered for each referral. The primary outcome was the number of circumcisions performed per month in each facility. To assess the effect of the intervention, a difference-in-difference analysis was performed using longitudinal data from the intervention facilities and 22 nonintervention facilities. A questionnaire was also implemented to understand men's perceptions of the intervention. Results: During the 8-month intervention period, 1222 men over 18 years of age were circumcised in intervention facilities. In the first 5 months, 699 circumcision clients were enrolled and 385 clients brought a referral voucher given to them by an enrolled client. Difference-in-difference analyses did not show a significant increase in circumcisions performed in intervention facilities. However, circumcision clients reported that the referral incentive motivated them to encourage their friends to seek male circumcision. Peer referrals were also reported to be an important factor in men's decisions because 78% of clients who were referred reported that talking with a circumcised friend was important for their decision to get circumcised. Conclusions: The peer referral incentive intervention for male circumcision was feasible and acceptable. However, the intervention did not have a significant effect on demand for male circumcision. Barriers to circumcision and features of the intervention may have limited the effect of the intervention. Further efforts regarding encouraging male-to-male communication and evaluations with larger sample sizes are needed. PMID:27404006

  19. The characteristics of referring facilities and transferred hand surgery patients: factors associated with emergency patient transfers.

    PubMed

    Kuo, Phoebe; Hartzell, Tristan L; Eberlin, Kyle R; Miao, Diana; Zurakowski, David; Winograd, Jonathan M; Day, Charles S

    2014-03-19

    As emergency departments (EDs) become increasingly overwhelmed and specialist coverage in some EDs decreases, patients may be transferred to tertiary or quaternary facilities for specialized care to decrease patient load at transferring facilities. Our objective was to determine whether facilities that transferred patients for hand surgery had hand surgery coverage and to evaluate any nonmedical factors that might have been associated with transfer. A retrospective review was conducted for 1167 visits of hand and wrist patients seen in the EDs of two urban level-I trauma centers. The hand surgery capacity of referring facilities was determined by phone calls to the EDs. Univariate and multivariable analyses were conducted to identify nonmedical factors that could potentially affect the decision to transfer. A total of 155 (13.3%) of 1167 patients arrived from other facilities for specialized hand care. These patients were significantly more likely to be male (p = 0.02), have noncommercial insurance (p = 0.04), require an interpreter (p = 0.01), and arrive between 6:00 p.m. and midnight (p = 0.03). In a multivariable analysis, sex and insurance status were significantly associated with transfer (p < 0.05). The subset of ninety-five patients who were transferred from other EDs was significantly more likely to be male (p < 0.01) and arrive on weekends (p < 0.01) or between 6:00 p.m. and midnight (p < 0.01). Of these patients, seventy-seven (81%) were transferred from an ED that reported partial or full hand surgery coverage. However, only eight (10.4%) received a hand surgery evaluation prior to transfer. The low percentage of patients receiving hand surgery evaluations prior to transfer suggests that referring hospitals are not using their own hand surgeon resources. Nonmedical factors, including noncommercial insurance and off-hour time of initial arrival, may be associated with the decision to transfer patients. Identifying nonmedical factors associated with patient transfers and referrals can enlighten efforts to improve the quality and appropriate use of transfers for specialty care.

  20. A User's Guide for the Spacecraft Fire Safety Facility

    NASA Technical Reports Server (NTRS)

    Goldmeer, Jeffrey S.

    2000-01-01

    The Spacecraft Fire Safety Facility (SFSF) is a test facility that can be flown on NASA's reduced gravity aircraft to perform various types of combustion experiments under a variety of experimental conditions. To date, this facility has flown numerous times on the aircraft and has been used to perform experiments ranging from an examination of the effects transient depressurization on combustion, to ignition and flame spread. A list of pubfications/presentations based on experiments performed in the SFSF is included in the reference section. This facility consists of five main subsystems: combustion chamber, sample holders, gas flow system, imaging system, and the data acquisition/control system. Each of these subsystems will be reviewed in more detail. These subsystems provide the experiment operator with the ability to monitor and/or control numerous experimental parameters.

  1. A ``Cyber Wind Facility'' for HPC Wind Turbine Field Experiments

    NASA Astrophysics Data System (ADS)

    Brasseur, James; Paterson, Eric; Schmitz, Sven; Campbell, Robert; Vijayakumar, Ganesh; Lavely, Adam; Jayaraman, Balaji; Nandi, Tarak; Jha, Pankaj; Dunbar, Alex; Motta-Mena, Javier; Craven, Brent; Haupt, Sue

    2013-03-01

    The Penn State ``Cyber Wind Facility'' (CWF) is a high-fidelity multi-scale high performance computing (HPC) environment in which ``cyber field experiments'' are designed and ``cyber data'' collected from wind turbines operating within the atmospheric boundary layer (ABL) environment. Conceptually the ``facility'' is akin to a high-tech wind tunnel with controlled physical environment, but unlike a wind tunnel it replicates commercial-scale wind turbines operating in the field and forced by true atmospheric turbulence with controlled stability state. The CWF is created from state-of-the-art high-accuracy technology geometry and grid design and numerical methods, and with high-resolution simulation strategies that blend unsteady RANS near the surface with high fidelity large-eddy simulation (LES) in separated boundary layer, blade and rotor wake regions, embedded within high-resolution LES of the ABL. CWF experiments complement physical field facility experiments that can capture wider ranges of meteorological events, but with minimal control over the environment and with very small numbers of sensors at low spatial resolution. I shall report on the first CWF experiments aimed at dynamical interactions between ABL turbulence and space-time wind turbine loadings. Supported by DOE and NSF.

  2. Ground-water hydrology of Dugway Proving Ground and adjoining area, Tooele and Juab counties, Utah

    USGS Publications Warehouse

    Steiger, Judy I.; Freethey, Geoffrey W.

    2001-01-01

    Dugway Proving Ground (DPG) is a U.S. Department of Defense chemical, biological, and explosives testing facility in northwestern Utah.  The facility includes about 620 mi2 in Tooele County.  The town of Dugway, referred to as English Village, is the administrative headquarters for the military facility, the primary residential area, and community center.  The English Village area is located at the southern end of Skull Valley and is separated from the Fries area by a surface-water divide.  Most of the facility is located just to the west of Skull Valley in Government Creek Valley, Dugway Valley, and the Great Salt Lake Desert (fig. 1).

  3. Genotyping of Indian antigenic, vaccine, and field Brucella spp. using multilocus sequence typing.

    PubMed

    Shome, Rajeswari; Krithiga, Natesan; Shankaranarayana, Padmashree B; Jegadesan, Sankarasubramanian; Udayakumar S, Vishnu; Shome, Bibek Ranjan; Saikia, Girin Kumar; Sharma, Narendra Kumar; Chauhan, Harshad; Chandel, Bharat Singh; Jeyaprakash, Rajendhran; Rahman, Habibur

    2016-03-31

    Brucellosis is one of the most important zoonotic diseases that affects multiple livestock species and causes great economic losses. The highly conserved genomes of Brucella, with > 90% homology among species, makes it important to study the genetic diversity circulating in the country. A total of 26 Brucella spp. (4 reference strains and 22 field isolates) and 1 B. melitensis draft genome sequence from India (B. melitensis Bm IND1) were included for sequence typing. The field isolates were identified by biochemical tests and confirmed by both conventional and quantitative polymerase chain reaction (qPCR) targeting bcsp 31Brucella genus-specific marker. Brucella speciation and biotyping was done by Bruce ladder, probe qPCR, and AMOS PCRs, respectively, and genotyping was done by multilocus sequence typing (MLST). The MLST typing of 27 Brucella spp. revealed five distinct sequence types (STs); the B. abortus S99 reference strain and 21 B. abortus field isolates belonged to ST1. On the other hand, the vaccine strain B. abortus S19 was genotyped as ST5. Similarly, B. melitensis 16M reference strain and one B. melitensis field isolate were grouped into ST7. Another B. melitensis field isolate belonged to ST8 (draft genome sequence from India), and only B. suis 1330 reference strain was found to be ST14. The sequences revealed genetic similarity of the Indian strains to the global reference and field strains. The study highlights the usefulness of MLST for typing of field isolates and validation of reference strains used for diagnosis and vaccination against brucellosis.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carlsbad Field Office

    The Performance Demonstration Program (PDP) for headspace gases distributes blind audit samples in a gas matrix for analysis of volatile organic compounds (VOCs). Participating measurement facilities (i.e., fixed laboratories, mobile analysis systems, and on-line analytical systems) are located across the United States. Each sample distribution is termed a PDP cycle. These evaluation cycles provide an objective measure of the reliability of measurements performed for transuranic (TRU) waste characterization. The primary documents governing the conduct of the PDP are the Quality Assurance Program Document (QAPD) (DOE/CBFO-94-1012) and the Waste Isolation Pilot Plant (WIPP) Waste Analysis Plan (WAP) contained in the Hazardousmore » Waste Facility Permit (NM4890139088-TSDF) issued by the New Mexico Environment Department (NMED). The WAP requires participation in the PDP; the PDP must comply with the QAPD and the WAP. This plan implements the general requirements of the QAPD and the applicable requirements of the WAP for the Headspace Gas (HSG) PDP. Participating measurement facilities analyze blind audit samples of simulated TRU waste package headspace gases according to the criteria set by this PDP Plan. Blind audit samples (hereafter referred to as PDP samples) are used as an independent means to assess each measurement facility’s compliance with the WAP quality assurance objectives (QAOs). To the extent possible, the concentrations of VOC analytes in the PDP samples encompass the range of concentrations anticipated in actual TRU waste package headspace gas samples. Analyses of headspace gases are required by the WIPP to demonstrate compliance with regulatory requirements. These analyses must be performed by measurement facilities that have demonstrated acceptable performance in this PDP. These analyses are referred to as WIPP analyses and the TRU waste package headspace gas samples on which they are performed are referred to as WIPP samples in this document. Participating measurement facilities must analyze PDP samples using the same procedures used for routine waste characterization analyses of WIPP samples.« less

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carlsbad Field Office

    The Performance Demonstration Program (PDP) for headspace gases distributes sample gases of volatile organic compounds (VOCs) for analysis. Participating measurement facilities (i.e., fixed laboratories, mobile analysis systems, and on-line analytical systems) are located across the United States. Each sample distribution is termed a PDP cycle. These evaluation cycles provide an objective measure of the reliability of measurements performed for transuranic (TRU) waste characterization. The primary documents governing the conduct of the PDP are the Quality Assurance Program Document (QAPD) (DOE/CBFO-94-1012) and the Waste Isolation Pilot Plant (WIPP) Waste Analysis Plan (WAP) contained in the Hazardous Waste Facility Permit (NM4890139088-TSDF) issuedmore » by the New Mexico Environment Department (NMED). The WAP requires participation in the PDP; the PDP must comply with the QAPD and the WAP. This plan implements the general requirements of the QAPD and the applicable requirements of the WAP for the Headspace Gas (HSG) PDP. Participating measurement facilities analyze blind audit samples of simulated TRU waste package headspace gases according to the criteria set by this PDP Plan. Blind audit samples (hereafter referred to as PDP samples) are used as an independent means to assess each measurement facility’s compliance with the WAP quality assurance objectives (QAOs). To the extent possible, the concentrations of VOC analytes in the PDP samples encompass the range of concentrations anticipated in actual TRU waste package headspace gas samples. Analyses of headspace gases are required by the WIPP to demonstrate compliance with regulatory requirements. These analyses must be performed by measurement facilities that have demonstrated acceptable performance in this PDP. These analyses are referred to as WIPP analyses and the TRU waste package headspace gas samples on which they are performed are referred to as WIPP samples in this document. Participating measurement facilities must analyze PDP samples using the same procedures used for routine waste characterization analyses of WIPP samples.« less

  6. Dosimetry for Small and Nonstandard Fields

    NASA Astrophysics Data System (ADS)

    Junell, Stephanie L.

    The proposed small and non-standard field dosimetry protocol from the joint International Atomic Energy Agency (IAEA) and American Association of Physicist in Medicine working group introduces new reference field conditions for ionization chamber based reference dosimetry. Absorbed dose beam quality conversion factors (kQ factors) corresponding to this formalism were determined for three different models of ionization chambers: a Farmer-type ionization chamber, a thimble ionization chamber, and a small volume ionization chamber. Beam quality correction factor measurements were made in a specially developed cylindrical polymethyl methacrylate (PMMA) phantom and a water phantom using thermoluminescent dosimeters (TLDs) and alanine dosimeters to determine dose to water. The TLD system for absorbed dose to water determination in high energy photon and electron beams was fully characterized as part of this dissertation. The behavior of the beam quality correction factor was observed as it transfers the calibration coefficient from the University of Wisconsin Accredited Dosimetry Calibration Laboratory (UWADCL) 60Co reference beam to the small field calibration conditions of the small field formalism. TLD-determined beam quality correction factors for the calibration conditions investigated ranged from 0.97 to 1.30 and had associated standard deviations from 1% to 3%. The alanine-determined beam quality correction factors ranged from 0.996 to 1.293. Volume averaging effects were observed with the Farmer-type ionization chamber in the small static field conditions. The proposed small and non-standard field dosimetry protocols new composite-field reference condition demonstrated its potential to reduce or remove ionization chamber volume dependancies, but the measured beam quality correction factors were not equal to the standard CoP's kQ, indicating a change in beam quality in the small and non-standard field dosimetry protocols new composite-field reference condition relative to the standard broad beam reference conditions. The TLD- and alanine-determined beam quality correction factors in the composite-field reference conditions were approximately 3% greater and differed by more than one standard deviation from the published TG-51 kQ values for all three chambers.

  7. Unravelling referral paths relating to the dental care of children: a study in Liverpool.

    PubMed

    Harris, Rebecca V; Pender, Susan M; Merry, Alison; Leo, Anthony

    2008-04-01

    To describe primary care referral networks relating to children's dental care and the main influences on referral decisions taken by dentists working in a primary care setting. A postal questionnaire to all 130 general dental practitioners (GDPs) in contract with Primary Care Trusts (PCTs), and 24 Community Dental Service (CDS) dentists in Liverpool. Characteristics of patient groups and factors influencing the choice of referral pathway of children referred from primary dental care. There were good responses rates (110 [85%] GDPs and 22 [92%] CDS dentists). The two main reasons why GDPs referred children to hospitals were (a) for treatment under general anaesthetic (GA) or relative analgesia (RA) and (b) for restorative care of dentally anxious children. GDPs also referred anxious children requiring simple restorative care and/or RA to the CDS. Only eight GDPs (7%) cited a lack of experience as a reason for referral of dentally anxious children for simple restorative care, compared to 53 (48%) who cited a lack of RA facilities, and 25 (23%) who cited financial considerations. GDPs refer children to both hospital services and the CDS, and identify a lack of RA facilities and economic pressures as key reasons for referral.

  8. High field superconducting solenoid for the LASA in Milan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Acerbi, E.; Aleessandria, F.; Baccaglioni, G.

    1988-03-01

    This paper presents the preliminary design of a 19 T superconducting facility for the LASA Laboratory in Milan. The main features of the facility, realized with NbTi, Nb/sub 3/Sn and V/sub 3/Ga coils, are represented by an high field homogeneity in the center region and by the presence of two cryostats which allow to operate separately the NbTi coil (useful bore 0.55 m) and the Nb/sub 3/Sn - V/sub 3/Ga coils (useful bore 0.05 - 0.07 m). The main parameters of the facility and the design criteria are discussed in details.

  9. Impact of Glacial Isostatic Adjustment on North America Plate Specific Terrestrial Reference Frame

    NASA Astrophysics Data System (ADS)

    Herring, Thomas; Melbourne, Tim; Murray, Mark; Floyd, Mike; Szeliga, Walter; King, Robert; Phillips, David; Puskas, Christine

    2017-04-01

    We examine the impact of incorporating glacial isostatic adjustment (GIA) models in determining the Euler poles for plate specific terrestrial reference frames. We will specifically examine the impact of GIA models on the realization of a North America Reference frame. We use a combination of the velocity fields determined by the Geodesy Advancing Geosciences and EarthScope (GAGE) Facility which analyzes GPS data from the Plate Boundary Observatory (PBO) and other geodetic quality GPS sites in North America, and from the ITRF2014 re-analysis. Initial analysis of the GAGE velocity field shows reduced root-mean-square (RMS) scatter of velocity estimate residuals when the North America Euler pole is estimated including the ICE-6G GIA mode. The reduction in the north-south direction is from 0.69 mm/yr to 0.52 mm/yr, in the east-west direction from 0.34 mm/yr to 0.30 mm/yr and in height from 0.93 mm/yr to 0.72 mm/yr. The reduction in the height RMS is not surprising since the contemporary geodetic height velocity estimates are used in the developing the ICE-6G model. Contemporary horizontal motions are not used the GIA model development, and the reduction in horizontal RMS provides a partial validation of the model. There is no reduction in the horizontal velocity residual when the ICE-5G model is used. Although removing the ICE-6G model before fitting an Euler pole for the North American plate reduces the RMS of the residuals, the pattern of residuals is still systematic suggesting possibly that a spherically symmetric viscosity model might not be adequate for accurate modeling of the horizontal motions associated with GIA in North America. This presentation in focus on the prospects and impacts of incorporating GIA models in plate-specific Euler poles with emphasis on North America.

  10. Mobile App to Assess Universal Access Compliance.

    PubMed

    Fransolet, Colette

    2016-01-01

    In terms of local legislation, South Africa has a handful of regulations that indirectly require Universal Access, which is then in itself largely described as facilities for people with disabilities. The most predominant set of regulations is the South African National Building Regulations, with a specific code which is deemed to satisfy standard titled South African National Standard (SANS) 10400 Part S: Facilities for Persons with Disabilities. Revised in 2011, this building regulation offers some technical guidelines specific to built infrastructure, and largely for people with functional mobility limitations. The description of the term "functional mobility limitations" in the context of this paper refers to people who make use of mobility aids to assist with their functionality in an environment, for example people who use walking aids (sticks, canes or walkers) and people who use wheelchairs. Albeit lacking in specifics around the requirements for other areas of functional limitations, including people who are blind, people who are deaf, and people with cognitive limitations, the SANS 10400 Part S is, to date, the most effective regulatory requirement in the country to assist with making facilities more accessible. With only a few experts in South Africa working in the field, the ability to offer clients Universal Access Reviews in terms of basic compliance with the SANS 10400 Part S is limited by two major factors. Firstly, the costs associated with employing experts in the field to review infrastructure is mostly too exorbitant for clients to carry. Secondly, the amount of time taken to perform reviews onsite and then collate the information into a coherent report for the client is far too long. These aspects result in a gap between clients wanting to meet the requirements, and being able to have the work completed in a reasonable amount of time. To overcome the challenge of larger institutions and organizations wanting to have their facilities reviewed in terms of compliance with National Building Regulations, within a tight budget as well as within minimal timeframes, an innovative mobile application was developed by Universal Design Africa. This App heralds the dawn of a new method to measure universal access compliance. The operation and format of this technology and its application could be adapted to meet all forms of compliance and information gathering, including international regulations and best practice.

  11. AN ASSESSMENT OF GROUND TRUTH VARIABILITY USING A "VIRTUAL FIELD REFERENCE DATABASE"

    EPA Science Inventory



    A "Virtual Field Reference Database (VFRDB)" was developed from field measurment data that included location and time, physical attributes, flora inventory, and digital imagery (camera) documentation foy 1,01I sites in the Neuse River basin, North Carolina. The sampling f...

  12. New generation non-stationary portable neutron generators for biophysical applications of Neutron Activation Analysis.

    PubMed

    Marchese, N; Cannuli, A; Caccamo, M T; Pace, C

    2017-01-01

    Neutron sources are increasingly employed in a wide range of research fields. For some specific purposes an alternative to existing large-scale neutron scattering facilities, can be offered by the new generation of portable neutron devices. This review reports an overview for such recently available neutron generators mainly addressed to biophysics applications with specific reference to portable non-stationary neutron generators applied in Neutron Activation Analysis (NAA). The review reports a description of a typical portable neutron generator set-up addressed to biophysics applications. New generation portable neutron devices, for some specific applications, can constitute an alternative to existing large-scale neutron scattering facilities. Deuterium-Deuterium pulsed neutron sources able to generate 2.5MeV neutrons, with a neutron yield of 1.0×10 6 n/s, a pulse rate of 250Hz to 20kHz and a duty factor varying from 5% to 100%, when combined with solid-state photon detectors, show that this kind of compact devices allow rapid and user-friendly elemental analysis. "This article is part of a Special Issue entitled "Science for Life" Guest Editor: Dr. Austen Angell, Dr. Salvatore Magazù and Dr. Federica Migliardo". Copyright © 2016 Elsevier B.V. All rights reserved.

  13. A study on photoelectrochemical properties of ZnO@ZnS nanostructures synthesized via facile ion-exchange approach

    NASA Astrophysics Data System (ADS)

    Sharma, Akash; Sahoo, Pooja; Thangavel, R.

    2018-05-01

    In this work, ZnO nanorods (NRs) were fabricated, on cleaned ITO substrates by using sol-gel spin coating followed by hydrothermal technique. In order to coat zinc sulphide (ZnS) layers on the earlier prepared NRs a facile ion-exchange approach was adopted. The ZnO@ZnS nanostructures so prepared were characterised by using X-ray diffraction (XRD), field emission scanning electron microscopy (FESEM), UV-visible spectroscopy and photoelectrochemical study. XRD spectra confirmed the hexagonal wurtzite structure of all the samples along with preferential c-axis orientation. Further it was also observed from the FESEM images that sulfidation process doesn't affect the structure of ZnO NRs arrays. From the absorption spectra it can be clearly observed that the light absorbing property has increased in within the visible range due to the formation of ZnS layer on the ZnO nanostructures, which is not possible for either of the material individually. The cyclic voltammetry results indicates the enhancement in photocurrent density after illumination for the synthesized nanostructures. The electrocatalytic behaviour of ZnO@ZnS electrodes have been studied using a 3-electrode system in presence of 0.1M NaOH electrolyte solution with respect to an Ag/AgCl reference electrode.

  14. Designing for Education: Compendium of Exemplary Educational Facilities 2011

    ERIC Educational Resources Information Center

    OECD Publishing (NJ3), 2011

    2011-01-01

    "Designing for Education: Compendium of Exemplary Educational Facilities 2011" showcases over 60 recently built or refurbished educational facilities from 28 countries. Collectively, these projects demonstrate state-of-the-art design in this field and each one is lavishly illustrated with colour photos, plans and descriptions. [A free PDF is…

  15. 37 CFR 102.25 - Disclosure of requested records to individuals.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... which (i) A search for and collection of requested records from inactive storage, field facilities or... hours; (ii) Transfer of records to a Federal facility more convenient to the individual may be arranged, but only if the Privacy Officer determines that a suitable facility is available, that the individual...

  16. Effects of a Facility Dog on Student Learning and Learning Environment

    ERIC Educational Resources Information Center

    Bradley, Jordana; Maldonado, Nancy

    2013-01-01

    Educators must consider alternative teaching strategies. Facility dogs as an instructional enhancement are an innovative teaching approach. This case study, guided by human-animal bond theory, investigated how the presence of a trained facility dog, Smooch, affected the school environment. Interviews, field notes and observations were used to…

  17. SU-E-T-590: Optimizing Magnetic Field Strengths with Matlab for An Ion-Optic System in Particle Therapy Consisting of Two Quadrupole Magnets for Subsequent Simulations with the Monte-Carlo Code FLUKA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baumann, K; Weber, U; Simeonov, Y

    Purpose: Aim of this study was to optimize the magnetic field strengths of two quadrupole magnets in a particle therapy facility in order to obtain a beam quality suitable for spot beam scanning. Methods: The particle transport through an ion-optic system of a particle therapy facility consisting of the beam tube, two quadrupole magnets and a beam monitor system was calculated with the help of Matlab by using matrices that solve the equation of motion of a charged particle in a magnetic field and field-free region, respectively. The magnetic field strengths were optimized in order to obtain a circular andmore » thin beam spot at the iso-center of the therapy facility. These optimized field strengths were subsequently transferred to the Monte-Carlo code FLUKA and the transport of 80 MeV/u C12-ions through this ion-optic system was calculated by using a user-routine to implement magnetic fields. The fluence along the beam-axis and at the iso-center was evaluated. Results: The magnetic field strengths could be optimized by using Matlab and transferred to the Monte-Carlo code FLUKA. The implementation via a user-routine was successful. Analyzing the fluence-pattern along the beam-axis the characteristic focusing and de-focusing effects of the quadrupole magnets could be reproduced. Furthermore the beam spot at the iso-center was circular and significantly thinner compared to an unfocused beam. Conclusion: In this study a Matlab tool was developed to optimize magnetic field strengths for an ion-optic system consisting of two quadrupole magnets as part of a particle therapy facility. These magnetic field strengths could subsequently be transferred to and implemented in the Monte-Carlo code FLUKA to simulate the particle transport through this optimized ion-optic system.« less

  18. Quality of Malaria Case Management in Malawi: Results from a Nationally Representative Health Facility Survey

    PubMed Central

    Steinhardt, Laura C.; Chinkhumba, Jobiba; Wolkon, Adam; Luka, Madalitso; Luhanga, Misheck; Sande, John; Oyugi, Jessica; Ali, Doreen; Mathanga, Don; Skarbinski, Jacek

    2014-01-01

    Background Malaria is endemic throughout Malawi, but little is known about quality of malaria case management at publicly-funded health facilities, which are the major source of care for febrile patients. Methods In April–May 2011, we conducted a nationwide, geographically-stratified health facility survey to assess the quality of outpatient malaria diagnosis and treatment. We enrolled patients presenting for care and conducted exit interviews and re-examinations, including reference blood smears. Moreover, we assessed health worker readiness (e.g., training, supervision) and health facility capacity (e.g. availability of diagnostics and antimalarials) to provide malaria case management. All analyses accounted for clustering and unequal selection probabilities. We also used survey weights to produce estimates of national caseloads. Results At the 107 facilities surveyed, most of the 136 health workers interviewed (83%) had received training on malaria case management. However, only 24% of facilities had functional microscopy, 15% lacked a thermometer, and 19% did not have the first-line artemisinin-based combination therapy (ACT), artemether-lumefantrine, in stock. Of 2,019 participating patients, 34% had clinical malaria (measured fever or self-reported history of fever plus a positive reference blood smear). Only 67% (95% confidence interval (CI): 59%, 76%) of patients with malaria were correctly prescribed an ACT, primarily due to missed malaria diagnosis. Among patients without clinical malaria, 31% (95% CI: 24%, 39%) were prescribed an ACT. By our estimates, 1.5 million of the 4.4 million malaria patients seen in public facilities annually did not receive correct treatment, and 2.7 million patients without clinical malaria were inappropriately given an ACT. Conclusions Malawi has a high burden of uncomplicated malaria but nearly one-third of all patients receive incorrect malaria treatment, including under- and over-treatment. To improve malaria case management, facilities must at minimum have basic case management tools, and health worker performance in diagnosing malaria must be improved. PMID:24586497

  19. Quality of malaria case management in Malawi: results from a nationally representative health facility survey.

    PubMed

    Steinhardt, Laura C; Chinkhumba, Jobiba; Wolkon, Adam; Luka, Madalitso; Luhanga, Misheck; Sande, John; Oyugi, Jessica; Ali, Doreen; Mathanga, Don; Skarbinski, Jacek

    2014-01-01

    Malaria is endemic throughout Malawi, but little is known about quality of malaria case management at publicly-funded health facilities, which are the major source of care for febrile patients. In April-May 2011, we conducted a nationwide, geographically-stratified health facility survey to assess the quality of outpatient malaria diagnosis and treatment. We enrolled patients presenting for care and conducted exit interviews and re-examinations, including reference blood smears. Moreover, we assessed health worker readiness (e.g., training, supervision) and health facility capacity (e.g. availability of diagnostics and antimalarials) to provide malaria case management. All analyses accounted for clustering and unequal selection probabilities. We also used survey weights to produce estimates of national caseloads. At the 107 facilities surveyed, most of the 136 health workers interviewed (83%) had received training on malaria case management. However, only 24% of facilities had functional microscopy, 15% lacked a thermometer, and 19% did not have the first-line artemisinin-based combination therapy (ACT), artemether-lumefantrine, in stock. Of 2,019 participating patients, 34% had clinical malaria (measured fever or self-reported history of fever plus a positive reference blood smear). Only 67% (95% confidence interval (CI): 59%, 76%) of patients with malaria were correctly prescribed an ACT, primarily due to missed malaria diagnosis. Among patients without clinical malaria, 31% (95% CI: 24%, 39%) were prescribed an ACT. By our estimates, 1.5 million of the 4.4 million malaria patients seen in public facilities annually did not receive correct treatment, and 2.7 million patients without clinical malaria were inappropriately given an ACT. Malawi has a high burden of uncomplicated malaria but nearly one-third of all patients receive incorrect malaria treatment, including under- and over-treatment. To improve malaria case management, facilities must at minimum have basic case management tools, and health worker performance in diagnosing malaria must be improved.

  20. Urinary Concentrations of Bisphenols and Their Association with Biomarkers of Oxidative Stress in People Living Near E-Waste Recycling Facilities in China.

    PubMed

    Zhang, Tao; Xue, Jingchuan; Gao, Chuan-zi; Qiu, Rong-liang; Li, Yan-xi; Li, Xiao; Huang, Ming-zhi; Kannan, Kurunthachalam

    2016-04-05

    In this study, concentrations of bisphenol A (BPA) and seven other bisphenols (BPs) were measured in urine samples collected from people living in and around e-waste dismantling facilities, and in matched reference population from rural and urban areas in China. BPA, bisphenol S (BPS), and bisphenol F (BPF) were frequently detected (detection frequencies: > 90%) in urine samples collected from individuals who live near e-waste facilities, with geometric mean (GM) concentrations of 2.99 (or 3.75), 0.361 (or 0.469), and 0.349 (or 0.435) ng/mL (or μg/g Cre), respectively; the other five BPs were rarely found in urine samples, regardless of the sampling location. The urinary concentrations of BPA and BPF, but not BPS, were significantly higher in individuals from e-waste recycling locations than did individuals from a rural reference location. Our findings indicated that e-waste dismantling activities contribute to human exposure to BPA and BPF. 8-Hydroxy-2'-deoxyguanosine (8-OHdG) was measured in urine as a marker of oxidative stress. In the e-waste dismantling location, urinary 8-OHdG was significantly and positively correlated (p < 0.001) with urinary BPA and BPS, but not BPF; a similar correlation was also observed in reference sites. These findings suggest that BPA and BPS exposures are associated with elevated oxidative stress.

  1. Annual Data Summary for 1986 CERC (Coastal Engineering Research Center) Field Research Facility. Volume 1. Main Text and Appendix A

    DTIC Science & Technology

    1988-08-01

    Waterways Experiment Station, Corps of Engineers PO Box 631, Vicksburg, Mississippi 39180-0631 DTI ~;~c~v ~ jAUG 291988 : H Ke August 1988 Final Report...PART I: INTRODUCTION ................................................ 3 Background ........................................................ 3...Information Service, 5285 Port Royal Road, Springfield, VA. 22161. 2 ANNUAL DATA SUMMARY FOR 1986 CERC FIELD RESEARCH FACILITY PART I: INTRODUCTION

  2. EPM - The European Facility for human physiology research on ISS.

    PubMed

    Rieschel, Mats; Nasca, Rosario; Junk, Peter; Gerhard, Ingo

    2002-07-01

    The European Physiology Modules (EPM) Facility is one of the four major Space Station facilities being developed within the framework of ESA's Microgravity Facilities for Columbus (MFC) programme. In order to allow a wide spectrum of physiological studies in weightlessness conditions, the facility provides the infrastructure to accommodate a variable set of scientific equipment. The initial EPM configuration supports experiments in the fields of neuroscience, bone & muscle research, cardiovascular research and metabolism. The International Space Life Science Working Group (ISLSWG) has recommended co-locating EPM with the 2 NASA Human Research Facility racks.

  3. A high resolution cavity BPM for the CLIC Test Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chritin, N.; Schmickler, H.; Soby, L.

    2010-08-01

    In frame of the development of a high resolution BPM system for the CLIC Main Linac we present the design of a cavity BPM prototype. It consists of a waveguide loaded dipole mode resonator and a monopole mode reference cavity, both operating at 15 GHz, to be compatible with the bunch frequencies at the CLIC Test Facility. Requirements, design concept, numerical analysis, and practical considerations are discussed.

  4. Workplan/RCRA Facility Investigation/Remedial Investigation Report for the Old Radioactive Waste Burial Ground 643-E, S01-S22 - Volume I - Text and Volume II - Appendices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Conner, K.R.

    This document presents the assessment of environmental impacts resulting from releases of hazardous substances from the facilities in the Old Radioactive Waste Burial Ground 643-E, including Solvent Tanks 650-01E to 650-22E, also referred to as Solvent Tanks at the Savannah River Site, Aiken, South Carolina.

  5. Making PACS the present, not the future.

    PubMed

    Hunt, D

    1998-01-01

    Why haven't you moved forward with PACS? Have you just procrastinated or does your facility have legitimate reasons? Some say the technology is too confusing or too new, while others say the cost of PACS is too high. Many facilities say they haven't found a satisfactory way to deal with the conflicting opinions of their radiologists, IS department, administration, referring physicians and staff. Take time to compare the technology you do understand with something familiar such as your own PC or perhaps the current networks inside your facility. You'll soon begin to see that PACS is not a new technology, but rather a new methodology. To handle the perceived high cost of PACS, remember that every facility has different needs. Look at your work flow and then the many byproducts of PACS, such as marketing. If you are the first in your area to implement this new technology, you'll gain a marketing advantage in competing for referring physicians and managed care referral business. Follow the process you use to purchase other products, such as CT or MRI, as you investigate the vendors. Finally, make a plan! Determine departmental goals and gather information from vendors. Create a timeline, a financial plan and your marketing strategy. Together, these steps will help move PACS into the present for you.

  6. A formalism for reference dosimetry in photon beams in the presence of a magnetic field

    NASA Astrophysics Data System (ADS)

    van Asselen, B.; Woodings, S. J.; Hackett, S. L.; van Soest, T. L.; Kok, J. G. M.; Raaymakers, B. W.; Wolthaus, J. W. H.

    2018-06-01

    A generic formalism is proposed for reference dosimetry in the presence of a magnetic field. Besides the regular correction factors from the conventional reference dosimetry formalisms, two factors are used to take into account magnetic field effects: (1) a dose conversion factor to correct for the change in local dose distribution and (2) a correction of the reading of the dosimeter used for the reference dosimetry measurements. The formalism was applied to the Elekta MRI-Linac, for which the 1.5 T magnetic field is orthogonal to the 7 MV photon beam. For this setup at reference conditions it was shown that the dose decreases with increasing magnetic field strength. The reduction in local dose for a 1.5 T transverse field, compared to no field is 0.51%  ±  0.03% at the reference point of 10 cm depth. The effect of the magnetic field on the reading of the dosimeter was measured for two waterproof ionization chambers types (PTW 30013 and IBA FC65-G) before and after multiple ramp-up and ramp-downs of the magnetic field. The chambers were aligned perpendicular and parallel to the magnetic field. The corrections of the readings of the perpendicularly aligned chambers were 0.967  ±  0.002 and 0.957  ±  0.002 for respectively the PTW and IBA ionization chambers. In the parallel alignment the corrections were small; 0.997  ±  0.001 and 1.002  ±  0.003 for the PTW and IBA chamber respectively. The change in reading due to the magnetic field can be measured by individual departments. The proposed formalism can be used to determine the correction factors needed to establish the absorbed dose in a magnetic field. It requires Monte Carlo simulations of the local dose and measurements of the response of the dosimeter. The formalism was successfully implemented for the MRI-Linac and is applicable for other field strengths and geometries.

  7. A formalism for reference dosimetry in photon beams in the presence of a magnetic field.

    PubMed

    van Asselen, B; Woodings, S J; Hackett, S L; van Soest, T L; Kok, J G M; Raaymakers, B W; Wolthaus, J W H

    2018-06-11

    A generic formalism is proposed for reference dosimetry in the presence of a magnetic field. Besides the regular correction factors from the conventional reference dosimetry formalisms, two factors are used to take into account magnetic field effects: (1) a dose conversion factor to correct for the change in local dose distribution and (2) a correction of the reading of the dosimeter used for the reference dosimetry measurements. The formalism was applied to the Elekta MRI-Linac, for which the 1.5 T magnetic field is orthogonal to the 7 MV photon beam. For this setup at reference conditions it was shown that the dose decreases with increasing magnetic field strength. The reduction in local dose for a 1.5 T transverse field, compared to no field is 0.51%  ±  0.03% at the reference point of 10 cm depth. The effect of the magnetic field on the reading of the dosimeter was measured for two waterproof ionization chambers types (PTW 30013 and IBA FC65-G) before and after multiple ramp-up and ramp-downs of the magnetic field. The chambers were aligned perpendicular and parallel to the magnetic field. The corrections of the readings of the perpendicularly aligned chambers were 0.967  ±  0.002 and 0.957  ±  0.002 for respectively the PTW and IBA ionization chambers. In the parallel alignment the corrections were small; 0.997  ±  0.001 and 1.002  ±  0.003 for the PTW and IBA chamber respectively. The change in reading due to the magnetic field can be measured by individual departments. The proposed formalism can be used to determine the correction factors needed to establish the absorbed dose in a magnetic field. It requires Monte Carlo simulations of the local dose and measurements of the response of the dosimeter. The formalism was successfully implemented for the MRI-Linac and is applicable for other field strengths and geometries.

  8. Background radiation measurements at high power research reactors

    NASA Astrophysics Data System (ADS)

    Ashenfelter, J.; Balantekin, B.; Baldenegro, C. X.; Band, H. R.; Barclay, G.; Bass, C. D.; Berish, D.; Bowden, N. S.; Bryan, C. D.; Cherwinka, J. J.; Chu, R.; Classen, T.; Davee, D.; Dean, D.; Deichert, G.; Dolinski, M. J.; Dolph, J.; Dwyer, D. A.; Fan, S.; Gaison, J. K.; Galindo-Uribarri, A.; Gilje, K.; Glenn, A.; Green, M.; Han, K.; Hans, S.; Heeger, K. M.; Heffron, B.; Jaffe, D. E.; Kettell, S.; Langford, T. J.; Littlejohn, B. R.; Martinez, D.; McKeown, R. D.; Morrell, S.; Mueller, P. E.; Mumm, H. P.; Napolitano, J.; Norcini, D.; Pushin, D.; Romero, E.; Rosero, R.; Saldana, L.; Seilhan, B. S.; Sharma, R.; Stemen, N. T.; Surukuchi, P. T.; Thompson, S. J.; Varner, R. L.; Wang, W.; Watson, S. M.; White, B.; White, C.; Wilhelmi, J.; Williams, C.; Wise, T.; Yao, H.; Yeh, M.; Yen, Y.-R.; Zhang, C.; Zhang, X.; Prospect Collaboration

    2016-01-01

    Research reactors host a wide range of activities that make use of the intense neutron fluxes generated at these facilities. Recent interest in performing measurements with relatively low event rates, e.g. reactor antineutrino detection, at these facilities necessitates a detailed understanding of background radiation fields. Both reactor-correlated and naturally occurring background sources are potentially important, even at levels well below those of importance for typical activities. Here we describe a comprehensive series of background assessments at three high-power research reactors, including γ-ray, neutron, and muon measurements. For each facility we describe the characteristics and identify the sources of the background fields encountered. The general understanding gained of background production mechanisms and their relationship to facility features will prove valuable for the planning of any sensitive measurement conducted therein.

  9. On the Helicity of Open Magnetic Fields

    NASA Astrophysics Data System (ADS)

    Prior, C.; Yeates, A. R.

    2014-06-01

    We reconsider the topological interpretation of magnetic helicity for magnetic fields in open domains, and relate this to the relative helicity. Specifically, our domains stretch between two parallel planes, and each of these ends may be magnetically open. It is demonstrated that, while the magnetic helicity is gauge-dependent, its value in any gauge may be physically interpreted as the average winding number among all pairs of field lines with respect to some orthonormal frame field. In fact, the choice of gauge is equivalent to the choice of reference field in the relative helicity, meaning that the magnetic helicity is no less physically meaningful. We prove that a particular gauge always measures the winding with respect to a fixed frame, and propose that this is normally the best choice. For periodic fields, this choice is equivalent to measuring relative helicity with respect to a potential reference field. However, for aperiodic fields, we show that the potential field can be twisted. We prove by construction that there always exists a possible untwisted reference field.

  10. Ion beams 12, Legnaro 6-8 June 2012, the 50 years (1961-2011) of the Legnaro Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ricci, Renato Angelo

    2013-07-18

    A short review of the history of the Legnaro Laboratory is presented since its foundation 50 years ago by Prof. A. Rostagni of the University of Padova. The evolution of the Laboratory as a national reference center for fundamental and applied nuclear physics researches is outlined, pointing out its transformation into the INFN National Laboratories in 1968. After the first CN VdG Accelerator of 5.5 MV operating in 1961 and the AN2000 devoted to interdisciplinary researches (1971), i.e. 40 years ago, ten years later the advent of the first heavy ion facility in Italy, the XTU Tandem accelerator, and latermore » on of the ALPI superconducting linear accelerator, was crucial for any future developments, not only in the field of nuclear physics but also for the evolution of interdisciplinary programmes with ion beams.« less

  11. The detection of planetary systems from Space Station - A star observation strategy

    NASA Technical Reports Server (NTRS)

    Mascy, Alfred C.; Nishioka, Ken; Jorgensen, Helen; Swenson, Byron L.

    1987-01-01

    A 10-20-yr star-observation program for the Space Station Astrometric Telescope Facility (ATF) is proposed and evaluated by means of computer simulations. The primary aim of the program is to detect stars with planetary systems by precise determination of their motion relative to reference stars. The designs proposed for the ATF are described and illustrated; the basic parameters of the 127 stars selected for the program are listed in a table; spacecraft and science constraints, telescope slewing rates, and the possibility of limiting the program sample to stars near the Galactic equator are discussed; and the effects of these constraints are investigated by simulating 1 yr of ATF operation. Viewing all sky regions, the ATF would have 81-percent active viewing time, observing each star about 200 times (56 h) per yr; only small decrements in this performance would result from limiting the viewing field.

  12. InSAR Maps of Deformation Covering Raft River, Idaho from 2007 to 2010

    DOE Data Explorer

    Reinisch, Elena C. (ORCID:0000000252211921)

    2007-03-11

    This dataset contains maps of deformation covering Raft River, Idaho from 2007 to 2010 calculated from interferometric synthetic aperture radar data. This dataset is used in the study entitled "Inferring geothermal reservoir processes at the Raft River Geothermal Field, Idaho, USA through modeling InSAR-measured surface deformation" by F. Liu, et al. This dataset was derived from raw SAR data from the Envisat satellite missions operated by the European Space Agency (ESA) that are copyrighted by ESA and were provided through the WInSAR consortium at the UNAVCO facility. All pair directories use the image acquired on 3/11/2007 as a reference image. To view specific information for each grd file, please use the GMT command "grdinfo" - e.g., for grd file In20070311_20071111/drho_utm.grd, use terminal command: grdinfo In20070311_20071111/drho_utm.grd

  13. Patient Mobility in Times of Austerity: A Legal and Policy Analysis of the Petru Case.

    PubMed

    Frischhut, Markus; Fahy, Nick

    2016-03-01

    The case-law of the Court of Justice (ECJ) on patient mobility was recently challenged by a ruling that a patient could go to Germany for treatment when facilities in Romanian hospitals were inadequate. Given the reported impact of austerity measures in the field of health care this raises the question; what is the impact of the ECJ's ruling on how Member States can manage expenditure and limit outflows of patients and how should such measures be legally evaluated? The objective of this article is to analyse potential impact on health systems in the context of increasing pressure on public financing for health. While the ECJ mainly referred to the requirement of treatment in due time, we also analyse possible austerity reductions of the basket of care against the background of EU law (i.e., EGJ case-law, patient mobility directive, Charter of Fundamental rights and social security regulation).

  14. National briefing summaries: Nuclear fuel cycle and waste management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schneider, K.J.; Lakey, L.T.; Silviera, D.J.

    The National Briefing Summaries is a compilation of publicly available information concerning the nuclear fuel cycle and radioactive waste management strategies and programs of 21 nations, including the United States and three international agencies that have publicized their activities in this field. It presents available highlight information with references that may be used by the reader for additional information. The information in this document is compiled primarily for use by the US Department of Energy and other US federal agencies and their contractors to provide summary information on radioactive waste management activities in other countries. This document provides an awarenessmore » to managers and technical staff of what is occurring in other countries with regard to strategies, activities, and facilities. The information may be useful in program planning to improve and benefit United States' programs through foreign information exchange. Benefits to foreign exchange may be derived through a number of exchange activities.« less

  15. Mapping of cosmic radiation dose in Croatia.

    PubMed

    Poje, M; Vuković, B; Radolić, V; Miklavčić, I; Faj, D; Varga Pajtler, M; Planinić, J

    2012-01-01

    The Earth is continually bombarded by high-energy particles coming from the outer space and the sun. These particles, termed cosmic radiation, interact with nuclei of atmospheric constituents and decrease in intensity with depth in the atmosphere. Measurements of photon and gamma radiation, performed with a Radiameter at 1 m above the ground, indicated dose rates of 50-100 nSv/h. The neutron dose rate was measured with the CR-39 track etch detector calibrated by the CERN-EU high-energy Reference Field (CERF) facility. Correlation between neutron dose rates and altitudes at 36 sites was examined in order to obtain a significant positive correlation coefficient; the resulting linear regression enabled estimation of a neutron dose at particular altitude. The measured neutron dose rate in Osijek (altitude of 89 m, latitude of 45.31° N) was 110 nSv/h. Copyright © 2011 Elsevier Ltd. All rights reserved.

  16. APPLICATION OF A "VITURAL FIELD REFERENCE DATABASE" TO ASSESS LAND-COVER MAP ACCURACIES

    EPA Science Inventory

    An accuracy assessment was performed for the Neuse River Basin, NC land-cover/use
    (LCLU) mapping results using a "Virtual Field Reference Database (VFRDB)". The VFRDB was developed using field measurement and digital imagery (camera) data collected at 1,409 sites over a perio...

  17. Assisting Your Preservice Teacher to Be Successful during Field Experiences

    ERIC Educational Resources Information Center

    Brett, Christine

    2006-01-01

    Field experience (junior practicum and student teaching) is considered by many to be the most influential part of a teacher preparation program (Cruickshank & Aramalin, 1986; Tannehill & Zakrajsek, 1988). During field experiences, preservice teachers (hereafter referred to as PSTs) are guided by a cooperating teacher (hereafter referred to as a…

  18. Ionization chamber-based reference dosimetry of intensity modulated radiation beams.

    PubMed

    Bouchard, Hugo; Seuntjens, Jan

    2004-09-01

    The present paper addresses reference dose measurements using thimble ionization chambers for quality assurance in IMRT fields. In these radiation fields, detector fluence perturbation effects invalidate the application of open-field dosimetry protocol data for the derivation of absorbed dose to water from ionization chamber measurements. We define a correction factor C(Q)IMRT to correct the absorbed dose to water calibration coefficient N(D, w)Q for fluence perturbation effects in individual segments of an IMRT delivery and developed a calculation method to evaluate the factor. The method consists of precalculating, using accurate Monte Carlo techniques, ionization chamber, type-dependent cavity air dose, and in-phantom dose to water at the reference point for zero-width pencil beams as a function of position of the pencil beams impinging on the phantom surface. These precalculated kernels are convolved with the IMRT fluence distribution to arrive at the dose-to-water-dose-to-cavity air ratio [D(a)w (IMRT)] for IMRT fields and with a 10x10 cm2 open-field fluence to arrive at the same ratio D(a)w (Q) for the 10x10 cm2 reference field. The correction factor C(Q)IMRT is then calculated as the ratio of D(a)w (IMRT) and D(a)w (Q). The calculation method was experimentally validated and the magnitude of chamber correction factors in reference dose measurements in single static and dynamic IMRT fields was studied. The results show that, for thimble-type ionization chambers the correction factor in a single, realistic dynamic IMRT field can be of the order of 10% or more. We therefore propose that for accurate reference dosimetry of complete n-beam IMRT deliveries, ionization chamber fluence perturbation correction factors must explicitly be taken into account.

  19. 38 CFR 13.2 - Field examinations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2010-07-01 2010-07-01 false Field examinations. 13.2... ADMINISTRATION, FIDUCIARY ACTIVITIES § 13.2 Field examinations. (a) Authority to conduct; generally. Field... facility Director are authorized, when assigned, to conduct investigations (field examinations) and examine...

  20. A 12 coil superconducting bumpy torus magnet facility for plasma research

    NASA Technical Reports Server (NTRS)

    Roth, J. R.; Holmes, A. D.; Keller, T. A.; Krawczonek, W. M.

    1972-01-01

    A summary is presented of the performance of the two-coil superconducting pilot rig which preceded the NASA Lewis bumpy torus. This pilot rig was operated for 550 experimental runs over a period of 7 years. The NASA Lewis bumpy torus facility consists of 12 superconducting coils, each with a 19 cm in diameter and capable of producing magnetic field strengths of 3.0 teslas on their axes. The magnets are equally spaced around a major circumference 1.52 m in diameter, and are mounted with the major axis of the torus vertical in a single vacuum tank 2.59 m in diameter. The design value of maximum magnetic field on the magnetic axis (3.0 teslas) was reached and exceeded. A maximum magnetic field of 3.23 teslas was held for a period of 60 minutes, and the coils did not go to normal. When the coils were charged to a maximum magnetic field of 3.35 teslas, the coil system was driven normal without damage to the facility.

  1. Characteristics and performance of a superconducting bumpy-torus magnet facility for plasma research

    NASA Technical Reports Server (NTRS)

    Roth, J. R.; Holmes, A. D.; Keller, T. A.; Krawczonek, W. M.

    1973-01-01

    The NASA Lewis bumpy-torus facility consists of 12 superconducting coils, each 19 cm i.d. and capable of 3.0 T on its axis. The coils are equally spaced around a toroidal array with a major diameter of 1.52 m; they are mounted with the major axis of the torus vertical in a single vacuum tank 2.6 m in diameter. Tests of the facility mapped out its magnetic, cryogenic, vacuum, mechanical, and electrical performance. The design value of the maximum magnetic field on the magnetic axis, 3.0 T, was reached and exceeded. A maximum magnetic field of 3.23 T was held for a period of 60 minutes. When the coils were charged to a maximum magnetic field of 3.35 T, the coil system went normal without apparent damage or degradation of performance.

  2. Advanced Technical Data Study

    DTIC Science & Technology

    1975-01-29

    will shut down automatically when condenser high pressure causes Pressure Limit Control high pressure switch to release. Press START switch (3...power cable (1) from facility pow- er. Troubleshoot cooling unit, for HI-LOW pressure switch repeated cutout. Refer to AGE ECU Cooling Unit...acti- vate when loss of air flow oc- curred, the pressure switch (3) failed to open circuit. Adjust or replace pressure switch . Refer to

  3. LSST summit facility construction progress report: reacting to design refinements and field conditions

    NASA Astrophysics Data System (ADS)

    Barr, Jeffrey D.; Gressler, William; Sebag, Jacques; Seriche, Jaime; Serrano, Eduardo

    2016-07-01

    The civil work, site infrastructure and buildings for the summit facility of the Large Synoptic Survey Telescope (LSST) are among the first major elements that need to be designed, bid and constructed to support the subsequent integration of the dome, telescope, optics, camera and supporting systems. As the contracts for those other major subsystems now move forward under the management of the LSST Telescope and Site (T and S) team, there has been inevitable and beneficial evolution in their designs, which has resulted in significant modifications to the facility and infrastructure. The earliest design requirements for the LSST summit facility were first documented in 2005, its contracted full design was initiated in 2010, and construction began in January, 2015. During that entire development period, and extending now roughly halfway through construction, there continue to be necessary modifications to the facility design resulting from the refinement of interfaces to other major elements of the LSST project and now, during construction, due to unanticipated field conditions. Changes from evolving interfaces have principally involved the telescope mount, the dome and mirror handling/coating facilities which have included significant variations in mass, dimensions, heat loads and anchorage conditions. Modifications related to field conditions have included specifying and testing alternative methods of excavation and contending with the lack of competent rock substrate where it was predicted to be. While these and other necessary changes are somewhat specific to the LSST project and site, they also exemplify inherent challenges related to the typical timeline for the design and construction of astronomical observatory support facilities relative to the overall development of the project.

  4. Superfund record of decision (EPA Region 1): Peterson/Puritan Site, Operable Unit 1, Cumberland/Lincoln, RI, September 1993

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1993-09-01

    This Decision Document presents the selected remedial action for the Peterson/Puritan, Inc. Superfund Site, Operable Unit 1, in Cumberland and Lincoln, Rhode Island. Operable Unit 1 contains two remediation areas. The CCL remediation area, a source of volatile organic contamination, includes the former Peterson/Puritan, Inc. facility, which is the Site's namesake (currently the CCL Custom Manufacturing facility, and referred to as CCL). The PAC remediation area includes the Pacific Anchor Chemical Corporation (PAC ) facility (formerly the Lonza and Universal Chemical Company facility), which is a source of arsenic and volatile organic contamination. Each remediation area is further split intomore » source and downgradient area components, respectively.« less

  5. LH2 airport requirements study

    NASA Technical Reports Server (NTRS)

    Brewer, G. D. (Editor)

    1976-01-01

    A preliminary assessment of the facilities and equipment which will be required at a representative airport is provided so liquid hydrogen LH2 can be used as fuel in long range transport aircraft in 1995-2000. A complete facility was conceptually designed, sized to meet the projected air traffic requirement. The facility includes the liquefaction plant, LH2, storage capability, and LH2 fuel handling system. The requirements for ground support and maintenance for the LH2 fueled aircraft were analyzed. An estimate was made of capital and operating costs which might be expected for the facility. Recommendations were made for design modifications to the reference aircraft, reflecting results of the analysis of airport fuel handling requirements, and for a program of additional technology development for air terminal related items.

  6. New vessels detected on wide-field imaging compared to two-field and seven-field imaging: implications for diabetic retinopathy screening image analysis.

    PubMed

    Talks, Stephen James; Manjunath, Vina; Steel, David H W; Peto, Tunde; Taylor, Roy

    2015-12-01

    Wide-field retinal imaging (Optomap), used for detecting diabetic retinopathy (DR), has been shown to compare well with seven-field early treatment diabetic retinopathy study (ETDRS) photographs. An Optomap 200° image covers 80% of the retinal surface, compared with the standard seven-field, 30° images, covering 30% of the retinal surface. In England, DR screening is performed by grading two, 45° images per eye, by the DR screening service (DRSS). To assess how often retinal new vessels (NVs) are observed on Optomap imaging, outside the DRSS two fields and standard seven-field photography, in a cohort of patients referred by the DRSS. A consecutive series of treatment naïve patients with DR, referred from DRSS with pre-proliferative or proliferative DR or diabetic maculopathy, were imaged with Optomap colour images, within 3 months of DRSS referral. The incidence and distribution of NVs were recorded in relation to two-field and seven-field areas. NVs were found in 102 of 1562 treatment naïve eyes (6.5%) of 781 patients. Of these, 72 were referred from DRSS as having NVs, but an additional 30 eyes (29% of NVs detected) from 25 patients were referred with a lesser degree of DR. In 25 of the 30 eyes without NVs reported on referral, NVs were located outside the standard two fields taken at DRSS, and in 12, NVs were outside the area covered on seven-field imaging (11.7% of eyes with NVs). Wide-field imaging with Optomap detected approximately 30% more NVs than standard two-field imaging in patients referred from a UK DRSS. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  7. What's New in Locker Rooms?

    ERIC Educational Resources Information Center

    Rittner-Heir, Robbin M.

    2001-01-01

    Discusses athletic facility design and renovation issues that exist because of increasing numbers of female athletes. Outlines renovation issues such as locker room facilities, space for sports equipment, and additional athletic fields. (GR)

  8. Temperature compensated and self-calibrated current sensor using reference magnetic field

    DOEpatents

    Yakymyshyn, Christopher Paul; Brubaker, Michael Allen; Yakymyshyn, Pamela Jane

    2007-10-09

    A method is described to provide temperature compensation and self-calibration of a current sensor based on a plurality of magnetic field sensors positioned around a current carrying conductor. A reference magnetic field generated within the current sensor housing is detected by the magnetic field sensors and is used to correct variations in the output signal due to temperature variations and aging.

  9. Temperature compensated current sensor using reference magnetic field

    DOEpatents

    Yakymyshyn, Christopher Paul; Brubaker, Michael Allen; Yakymyshyn, Pamela Jane

    2007-10-09

    A method is described to provide temperature compensation and self-calibration of a current sensor based on a plurality of magnetic field sensors positioned around a current carrying conductor. A reference magnetic field generated within the current sensor housing is detected by a separate but identical magnetic field sensor and is used to correct variations in the output signal due to temperature variations and aging.

  10. 32 CFR 103.2 - Applicability.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... healthcare system, at installations in the continental United States (CONUS) and outside of the continental... healthcare system at military installations or facilities OCONUS. Refer to DoDI 6495.02 for reporting options...

  11. 32 CFR 103.2 - Applicability.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... healthcare system, at installations in the continental United States (CONUS) and outside of the continental... healthcare system at military installations or facilities OCONUS. Refer to DoDI 6495.02 for reporting options...

  12. Simulation and measurements of the response of an air ionisation chamber exposed to a mixed high-energy radiation field.

    PubMed

    Vincke, Helmut; Forkel-Wirth, Doris; Perrin, Daniel; Theis, Chris

    2005-01-01

    CERN's radiation protection group operates a network of simple and robust ionisation chambers that are installed inside CERN's accelerator tunnels. These ionisation chambers are used for the remote reading of ambient dose rate equivalents inside the machines during beam-off periods. This Radiation Protection Monitor for dose rates due to Induced Radioactivity ('PMI', trade name: PTW, Type 34031) is a non-confined air ionisation plastic chamber which is operated under atmospheric pressure. Besides its current field of operation it is planned to extend the use of this detector in the Large Hadron Collider to measure radiation under beam operation conditions to obtain an indication of the machine performance. Until now, studies of the PMI detector have been limited to the response to photons. In order to evaluate its response to other radiation components, this chamber type was tested at CERF, the high-energy reference field facility at CERN. Six PMI detectors were installed around a copper target being irradiated by a mixed hadron beam with a momentum of 120 GeV c(-1). Each of the chosen detector positions was defined by a different radiation field, varying in type and energy of the incident particles. For all positions, detailed measurements and FLUKA simulations of the detector response were performed. This paper presents the promising comparison between the measurements and simulations and analyses the influence of the different particle types on the resulting detector response.

  13. College and University Facilities Guide for Health, Physical Education, Recreation, and Athletics.

    ERIC Educational Resources Information Center

    American Association for Health, Physical Education, and Recreation, Washington, DC.

    This guide presents information concerned with the planning of areas and facilities for athletics, recreation, outdoor education, and physical and health education. Swimming pools, service areas, ice skating, field houses, arenas, and stadiums are among the many facilities which are considered. Included are many diagrams and sketches giving…

  14. 40 CFR 63.2334 - Am I subject to this subpart?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) Oil and natural gas production field facilities, as the term “facility” is defined in § 63.761 of subpart HH. (2) Natural gas transmission and storage facilities, as the term “facility” is defined in § 63... distribution operations located at research and development facilities, consistent with section 112(c)(7) of...

  15. Influence of the magnetic field profile on ITER conductor testing

    NASA Astrophysics Data System (ADS)

    Nijhuis, A.; Ilyin, Y.; ten Kate, H. H. J.

    2006-08-01

    We performed simulations with the numerical CUDI-CICC code on a typical short ITER (International Thermonuclear Experimental Reactor) conductor test sample of dual leg configuration, as usually tested in the SULTAN test facility, and made a comparison with the new EFDA-Dipole test facility offering a larger applied DC field region. The new EFDA-Dipole test facility, designed for short sample testing of conductors for ITER, has a homogeneous high field region of 1.2 m, while in the SULTAN facility this region is three times shorter. The inevitable non-uniformity of the current distribution in the cable, introduced by the joints at both ends, has a degrading effect on voltage-current (VI) and voltage-temperature (VT) characteristics, particularly for these short samples. This can easily result in an underestimation or overestimation of the actual conductor performance. A longer applied DC high field region along a conductor suppresses the current non-uniformity by increasing the overall longitudinal cable electric field when reaching the current sharing mode. The numerical interpretation study presented here gives a quantitative analysis for a relevant practical case of a test of a short sample poloidal field coil insert (PFCI) conductor in SULTAN. The simulation includes the results of current distribution analysis from self-field measurements with Hall sensor arrays, current sharing measurements and inter-petal resistance measurements. The outcome of the simulations confirms that the current uniformity improves with a longer high field region but the 'measured' VI transition is barely affected, though the local peak voltages become somewhat suppressed. It appears that the location of the high field region and voltage taps has practically no influence on the VI curve as long as the transverse voltage components are adequately cancelled. In particular, for a thin conduit wall, the voltage taps should be connected to the conduit in the form of an (open) azimuthally soldered wire, averaging the transverse conduit surface potentials initiated in the joints.

  16. Evaluation of local electric fields generated by transcranial direct current stimulation with an extracephalic reference electrode based on realistic 3D body modeling

    NASA Astrophysics Data System (ADS)

    Im, Chang-Hwan; Park, Ji-Hye; Shim, Miseon; Chang, Won Hyuk; Kim, Yun-Hee

    2012-04-01

    In this study, local electric field distributions generated by transcranial direct current stimulation (tDCS) with an extracephalic reference electrode were evaluated to address extracephalic tDCS safety issues. To this aim, we generated a numerical model of an adult male human upper body and applied the 3D finite element method to electric current conduction analysis. In our simulations, the active electrode was placed over the left primary motor cortex (M1) and the reference electrode was placed at six different locations: over the right temporal lobe, on the right supraorbital region, on the right deltoid, on the left deltoid, under the chin, and on the right buccinator muscle. The maximum current density and electric field intensity values in the brainstem generated by the extracephalic reference electrodes were comparable to, or even less than, those generated by the cephalic reference electrodes. These results suggest that extracephalic reference electrodes do not lead to unwanted modulation of the brainstem cardio-respiratory and autonomic centers, as indicated by recent experimental studies. The volume energy density was concentrated at the neck area by the use of deltoid reference electrodes, but was still smaller than that around the active electrode locations. In addition, the distributions of elicited cortical electric fields demonstrated that the use of extracephalic reference electrodes might allow for the robust prediction of cortical modulations with little dependence on the reference electrode locations.

  17. HIV Testing, HIV Positivity, and Linkage and Referral Services in Correctional Facilities in the United States, 2009–2013

    PubMed Central

    Seth, Puja; Figueroa, Argelia; Wang, Guoshen; Reid, Laurie; Belcher, Lisa

    2016-01-01

    Background Because of health disparities, incarcerated persons are at higher risk for multiple health issues, including HIV. Correctional facilities have an opportunity to provide HIV services to an underserved population. This article describes Centers for Disease Control and Prevention (CDC)–funded HIV testing and service delivery in correctional facilities. Methods Data on HIV testing and service delivery were submitted to CDC by 61 health department jurisdictions in 2013. HIV testing, HIV positivity, receipt of test results, linkage, and referral services were described, and differences across demographic characteristics for linkage and referral services were assessed. Finally, trends were examined for HIV testing, HIV positivity, and linkage from 2009 to 2013. Results Of CDC-funded tests in 2013 among persons 18 years and older, 254,719 (7.9%) were conducted in correctional facilities. HIV positivity was 0.9%, and HIV positivity for newly diagnosed persons was 0.3%. Blacks accounted for the highest percentage of HIV-infected persons (1.3%) and newly diagnosed persons (0.5%). Only 37.9% of newly diagnosed persons were linked within 90 days; 67.5% were linked within any time frame; 49.7% were referred to partner services; and 45.2% were referred to HIV prevention services. There was a significant percent increase in HIV testing, overall HIV positivity, and linkage from 2009 to 2013. However, trends were stable for newly diagnosed persons. Conclusions Identification of newly diagnosed persons in correctional facilities has remained stable from 2009 to 2013. Correctional facilities seem to be reaching blacks, likely due to higher incarceration rates. The current findings indicate that improvements are needed in HIV testing strategies, service delivery during incarceration, and linkage to care postrelease. PMID:26462190

  18. Normative data for the Functional Movement Screen in male Gaelic field sports.

    PubMed

    Fox, Domhnaill; O'Malley, Edwenia; Blake, Catherine

    2014-08-01

    To determine normative values for the Functional Movement Screen (FMS) in Elite and Sub-Elite male Gaelic Football and Hurling players. A cross sectional study of functional movement in Gaelic games at Elite and Sub-Elite level. Players were video recorded completing the Functional Movement Screen Tool and scored post-test. Comparisons were analysed using Mann-Whitney U tests. Field testing in team gym facility and university biomechanics laboratory. A total of 62 players were tested. This consisted of 41 Hurling, and 21 Gaelic Football players. 30 of these participants were deemed Elite and 32 were deemed Sub-Elite. The mean age of the sample was 22.15 ± 3.02 years. Functional Movement Screen (FMS). The FMS mean score for the sample was 15.56 ± 1.46. The Elite group (15.8 ± 1.58) scored higher than the Sub-Elite group (15.34 ± 1.31) but there was no significant difference between groups. This study provides normative reference values for Gaelic Players. Elite Gaelic Players perform no better than a young, active population in the FMS indicating a potential problem with the FMS as a measure. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Design principles and field performance of a solar spectral irradiance meter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tatsiankou, V.; Hinzer, K.; Haysom, J.

    2016-08-01

    A solar spectral irradiance meter (SSIM), designed for measuring the direct normal irradiance (DNI) in six wavelength bands, has been combined with models to determine key atmospheric transmittances and the resulting spectral irradiance distribution of DNI under all sky conditions. The design principles of the SSIM, implementation of a parameterized transmittance model, and field performance comparisons of modeled solar spectra with reference radiometer measurements are presented. Two SSIMs were tested and calibrated at the National Renewable Energy Laboratory (NREL) against four spectroradiometers and an absolute cavity radiometer. The SSIMs' DNI was on average within 1% of the DNI values reportedmore » by one of NREL's primary absolute cavity radiometers. An additional SSIM was installed at the SUNLAB Outdoor Test Facility in September 2014, with ongoing collection of environmental and spectral data. The SSIM's performance in Ottawa was compared against a commercial pyrheliometer and a spectroradiometer over an eight month study. The difference in integrated daily spectral irradiance between the SSIM and the ASD spectroradiometer was found to be less than 1%. The cumulative energy density collected by the SSIM over this duration agreed with that measured by an Eppley model NIP pyrheliometer to within 0.5%. No degradation was observed.« less

  20. Feasibility study of glass dosimeter postal dosimetry audit of high-energy radiotherapy photon beams.

    PubMed

    Mizuno, Hideyuki; Kanai, Tatsuaki; Kusano, Yohsuke; Ko, Susumu; Ono, Mari; Fukumura, Akifumi; Abe, Kyoko; Nishizawa, Kanae; Shimbo, Munefumi; Sakata, Suoh; Ishikura, Satoshi; Ikeda, Hiroshi

    2008-02-01

    The characteristics of a glass dosimeter were investigated for its potential use as a tool for postal dose audits. Reproducibility, energy dependence, field size and depth dependence were compared to those of a thermoluminescence dosimeter (TLD), which has been the major tool for postal dose audits worldwide. A glass dosimeter, GD-302M (Asahi Techno Glass Co.) and a TLD, TLD-100 chip (Harshaw Co.) were irradiated with gamma-rays from a (60)Co unit and X-rays from a medical linear accelerator (4, 6, 10 and 20 MV). The dosimetric characteristics of the glass dosimeter were almost equivalent to those of the TLD, in terms of utility for dosimetry under the reference condition, which is a 10 x 10 cm(2) field and 10 cm depth. Because of its reduced fading, compared to the TLD, and easy quality control with the ID number, the glass dosimeter proved to be a suitable tool for postal dose audits. Then, we conducted postal dose surveys of over 100 facilities and got good agreement, with a standard deviation of about 1.3%. Based on this study, postal dose audits throughout Japan will be carried out using a glass dosimeter.