Sample records for reference gold standard

  1. 45 CFR 156.400 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ..., silver, gold, or platinum level of coverage is referred to as a standard bronze plan, a standard silver plan, a standard gold plan, and a standard platinum plan, respectively. Zero cost sharing plan...

  2. Bias in estimating accuracy of a binary screening test with differential disease verification

    PubMed Central

    Brinton, John T.; Ringham, Brandy M.; Glueck, Deborah H.

    2011-01-01

    SUMMARY Sensitivity, specificity, positive and negative predictive value are typically used to quantify the accuracy of a binary screening test. In some studies it may not be ethical or feasible to obtain definitive disease ascertainment for all subjects using a gold standard test. When a gold standard test cannot be used an imperfect reference test that is less than 100% sensitive and specific may be used instead. In breast cancer screening, for example, follow-up for cancer diagnosis is used as an imperfect reference test for women where it is not possible to obtain gold standard results. This incomplete ascertainment of true disease, or differential disease verification, can result in biased estimates of accuracy. In this paper, we derive the apparent accuracy values for studies subject to differential verification. We determine how the bias is affected by the accuracy of the imperfect reference test, the percent who receive the imperfect reference standard test not receiving the gold standard, the prevalence of the disease, and the correlation between the results for the screening test and the imperfect reference test. It is shown that designs with differential disease verification can yield biased estimates of accuracy. Estimates of sensitivity in cancer screening trials may be substantially biased. However, careful design decisions, including selection of the imperfect reference test, can help to minimize bias. A hypothetical breast cancer screening study is used to illustrate the problem. PMID:21495059

  3. Validation of a search strategy to identify nutrition trials in PubMed using the relative recall method.

    PubMed

    Durão, Solange; Kredo, Tamara; Volmink, Jimmy

    2015-06-01

    To develop, assess, and maximize the sensitivity of a search strategy to identify diet and nutrition trials in PubMed using relative recall. We developed a search strategy to identify diet and nutrition trials in PubMed. We then constructed a gold standard reference set to validate the identified trials using the relative recall method. Relative recall was calculated by dividing the number of references from the gold standard our search strategy identified by the total number of references in the gold standard. Our gold standard comprised 298 trials, derived from 16 included systematic reviews. The initial search strategy identified 242 of 298 references, with a relative recall of 81.2% [95% confidence interval (CI): 76.3%, 85.5%]. We analyzed titles and abstracts of the 56 missed references for possible additional terms. We then modified the search strategy accordingly. The relative recall of the final search strategy was 88.6% (95% CI: 84.4%, 91.9%). We developed a search strategy to identify diet and nutrition trials in PubMed with a high relative recall (sensitivity). This could be useful for establishing a nutrition trials register to support the conduct of future research, including systematic reviews. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  4. From plastic to gold: a unified classification scheme for reference standards in medical image processing

    NASA Astrophysics Data System (ADS)

    Lehmann, Thomas M.

    2002-05-01

    Reliable evaluation of medical image processing is of major importance for routine applications. Nonetheless, evaluation is often omitted or methodically defective when novel approaches or algorithms are introduced. Adopted from medical diagnosis, we define the following criteria to classify reference standards: 1. Reliance, if the generation or capturing of test images for evaluation follows an exactly determined and reproducible protocol. 2. Equivalence, if the image material or relationships considered within an algorithmic reference standard equal real-life data with respect to structure, noise, or other parameters of importance. 3. Independence, if any reference standard relies on a different procedure than that to be evaluated, or on other images or image modalities than that used routinely. This criterion bans the simultaneous use of one image for both, training and test phase. 4. Relevance, if the algorithm to be evaluated is self-reproducible. If random parameters or optimization strategies are applied, reliability of the algorithm must be shown before the reference standard is applied for evaluation. 5. Significance, if the number of reference standard images that are used for evaluation is sufficient large to enable statistically founded analysis. We demand that a true gold standard must satisfy the Criteria 1 to 3. Any standard only satisfying two criteria, i.e., Criterion 1 and Criterion 2 or Criterion 1 and Criterion 3, is referred to as silver standard. Other standards are termed to be from plastic. Before exhaustive evaluation based on gold or silver standards is performed, its relevance must be shown (Criterion 4) and sufficient tests must be carried out to found statistical analysis (Criterion 5). In this paper, examples are given for each class of reference standards.

  5. Criteria for Evaluating Interventions

    ERIC Educational Resources Information Center

    Miles, T. R.

    2007-01-01

    By common consent there is a "gold standard" in reference to which the efficacy of medical interventions needs to be evaluated. It is suggested in this paper that in educational research achievement of this gold standard is rarely possible. It does not follow, however, that research that falls short of this standard is therefore valueless; there…

  6. Gold standards and expert panels: a pulmonary nodule case study with challenges and solutions

    NASA Astrophysics Data System (ADS)

    Miller, Dave P.; O'Shaughnessy, Kathryn F.; Wood, Susan A.; Castellino, Ronald A.

    2004-05-01

    Comparative evaluations of reader performance using different modalities, e.g. CT with computer-aided detection (CAD) vs. CT without CAD, generally require a "truth" definition based on a gold standard. There are many situations in which a true invariant gold standard is impractical or impossible to obtain. For instance, small pulmonary nodules are generally not assessed by biopsy or resection. In such cases, it is common to use a unanimous consensus or majority agreement from an expert panel as a reference standard for actionability in lieu of the unknown gold standard for disease. Nonetheless, there are three major concerns about expert panel reference standards: (1) actionability is not synonymous with disease (2) it may be possible to obtain different conclusions about which modality is better using different rules (e.g. majority vs. unanimous consensus), and (3) the variability associated with the panelists is not formally captured in the p-values or confidence intervals that are generally produced for estimating the extent to which one modality is superior to the other. A multi-reader-multi-case (MRMC) receiver operating characteristic (ROC) study was performed using 90 cases, 15 readers, and a reference truth based on 3 experienced panelists. The primary analyses were conducted using a reference truth of unanimous consensus regarding actionability (3 out of 3 panelists). To assess the three concerns noted above: (1) additional data from the original radiology reports were compared to the panel (2) the complete analysis was repeated using different definitions of truth, and (3) bootstrap analyses were conducted in which new truth panels were constructed by picking 1, 2, or 3 panelists at random. The definition of the reference truth affected the results for each modality (CT with CAD and CT without CAD) considered by itself, but the effects were similar, so the primary analysis comparing the modalities was robust to the choice of the reference truth.

  7. Aluminium-gold reference material for the k0-standardisation of neutron activation analysis

    NASA Astrophysics Data System (ADS)

    Ingelbrecht, C.; Peetermans, F.; De Corte, F.; De Wispelaere, A.; Vandecasteele, C.; Courtijn, E.; D'Hondt, P.

    1991-05-01

    Gold is an excellent comparator material for the k0-standardisation of neutron activation analysis because of its convenient and well defined nuclear properties. The most suitable form for a reference material is a dilute aluminium-gold alloy, for which the self-shielding effect for neutrons is small. Castings of composition Al-0.1 wt.% Au were prepared by crucible-less levitation melting, which gives close control of ingot composition with minimal contamination of the melt. The alloy composition was checked using induction-coupled plasma source emission spectrometry. The homogeneity of the alloy was measured by neutron activation analysis and a relative standard deviation of the gold content of 0.30% was found (10 mg samples). Metallography revealed a homogeneous distribution of AuAl 2 particles. The alloy was certified as Reference Material CBNM-530, with certified gold mass fraction 0.100±0.002 wt.%.

  8. Mid-infrared reflectlance spectra (2.3-22 micions) of sulfur, gold, KBr, MgO, and halon

    NASA Technical Reports Server (NTRS)

    Nash, D. B.

    1986-01-01

    Biconical diffuse reflectance spectra in the mid-infrared are presented for powder and other solid forms of sulfur, gold, potassium bromide, magnesium oxide, and halon. Comparisons are made with previously published results of other investigators, and recommendations are made regarding the relative usefulnees of these materials as reflectance standards in the mid-IR. Sulfur has strong intrinsic bands at wavelengths greater than 7 microns that must be taken into account for its use as a reflectance standard. Some sulfur samples have hydrocarbon contaminants and in powder form may have adsorbed water, both of which produce bands in the 3-4-micron region. Potassium bromide has several weak intrinsic bands and is very sensitive to adsorbed water contamination; otherwise it is a good IR reference material. Magnesium oxide and halon have major bands structure and low reflectivity at wavelengths greater than 2.6 microns and thus are unsuitable as reference materials in the mid-IR. Vapor-deposited gold on fine sandpaper (600 grit) is very bright, spectrally flat, and fairly diffuse, so it is the superior material (of those examined) for reflectance reference material throughout the IR. Fine gold powder, on the other hand, is much less bright than evaporated gold, and its reflectivity at wavelengths greater than its particle size is highly sensitive to particle packing density.

  9. A framework for automatic creation of gold-standard rigid 3D-2D registration datasets.

    PubMed

    Madan, Hennadii; Pernuš, Franjo; Likar, Boštjan; Špiclin, Žiga

    2017-02-01

    Advanced image-guided medical procedures incorporate 2D intra-interventional information into pre-interventional 3D image and plan of the procedure through 3D/2D image registration (32R). To enter clinical use, and even for publication purposes, novel and existing 32R methods have to be rigorously validated. The performance of a 32R method can be estimated by comparing it to an accurate reference or gold standard method (usually based on fiducial markers) on the same set of images (gold standard dataset). Objective validation and comparison of methods are possible only if evaluation methodology is standardized, and the gold standard  dataset is made publicly available. Currently, very few such datasets exist and only one contains images of multiple patients acquired during a procedure. To encourage the creation of gold standard 32R datasets, we propose an automatic framework. The framework is based on rigid registration of fiducial markers. The main novelty is spatial grouping of fiducial markers on the carrier device, which enables automatic marker localization and identification across the 3D and 2D images. The proposed framework was demonstrated on clinical angiograms of 20 patients. Rigid 32R computed by the framework was more accurate than that obtained manually, with the respective target registration error below 0.027 mm compared to 0.040 mm. The framework is applicable for gold standard setup on any rigid anatomy, provided that the acquired images contain spatially grouped fiducial markers. The gold standard datasets and software will be made publicly available.

  10. Assessing operating characteristics of CAD algorithms in the absence of a gold standard

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roy Choudhury, Kingshuk; Paik, David S.; Yi, Chin A.

    2010-04-15

    Purpose: The authors examine potential bias when using a reference reader panel as ''gold standard'' for estimating operating characteristics of CAD algorithms for detecting lesions. As an alternative, the authors propose latent class analysis (LCA), which does not require an external gold standard to evaluate diagnostic accuracy. Methods: A binomial model for multiple reader detections using different diagnostic protocols was constructed, assuming conditional independence of readings given true lesion status. Operating characteristics of all protocols were estimated by maximum likelihood LCA. Reader panel and LCA based estimates were compared using data simulated from the binomial model for a range ofmore » operating characteristics. LCA was applied to 36 thin section thoracic computed tomography data sets from the Lung Image Database Consortium (LIDC): Free search markings of four radiologists were compared to markings from four different CAD assisted radiologists. For real data, bootstrap-based resampling methods, which accommodate dependence in reader detections, are proposed to test of hypotheses of differences between detection protocols. Results: In simulation studies, reader panel based sensitivity estimates had an average relative bias (ARB) of -23% to -27%, significantly higher (p-value <0.0001) than LCA (ARB -2% to -6%). Specificity was well estimated by both reader panel (ARB -0.6% to -0.5%) and LCA (ARB 1.4%-0.5%). Among 1145 lesion candidates LIDC considered, LCA estimated sensitivity of reference readers (55%) was significantly lower (p-value 0.006) than CAD assisted readers' (68%). Average false positives per patient for reference readers (0.95) was not significantly lower (p-value 0.28) than CAD assisted readers' (1.27). Conclusions: Whereas a gold standard based on a consensus of readers may substantially bias sensitivity estimates, LCA may be a significantly more accurate and consistent means for evaluating diagnostic accuracy.« less

  11. Device and methods for "gold standard" registration of clinical 3D and 2D cerebral angiograms

    NASA Astrophysics Data System (ADS)

    Madan, Hennadii; Likar, Boštjan; Pernuš, Franjo; Å piclin, Žiga

    2015-03-01

    Translation of any novel and existing 3D-2D image registration methods into clinical image-guidance systems is limited due to lack of their objective validation on clinical image datasets. The main reason is that, besides the calibration of the 2D imaging system, a reference or "gold standard" registration is very difficult to obtain on clinical image datasets. In the context of cerebral endovascular image-guided interventions (EIGIs), we present a calibration device in the form of a headband with integrated fiducial markers and, secondly, propose an automated pipeline comprising 3D and 2D image processing, analysis and annotation steps, the result of which is a retrospective calibration of the 2D imaging system and an optimal, i.e., "gold standard" registration of 3D and 2D images. The device and methods were used to create the "gold standard" on 15 datasets of 3D and 2D cerebral angiograms, whereas each dataset was acquired on a patient undergoing EIGI for either aneurysm coiling or embolization of arteriovenous malformation. The use of the device integrated seamlessly in the clinical workflow of EIGI. While the automated pipeline eliminated all manual input or interactive image processing, analysis or annotation. In this way, the time to obtain the "gold standard" was reduced from 30 to less than one minute and the "gold standard" of 3D-2D registration on all 15 datasets of cerebral angiograms was obtained with a sub-0.1 mm accuracy.

  12. Building a gold standard to construct search filters: a case study with biomarkers for oral cancer.

    PubMed

    Frazier, John J; Stein, Corey D; Tseytlin, Eugene; Bekhuis, Tanja

    2015-01-01

    To support clinical researchers, librarians and informationists may need search filters for particular tasks. Development of filters typically depends on a "gold standard" dataset. This paper describes generalizable methods for creating a gold standard to support future filter development and evaluation using oral squamous cell carcinoma (OSCC) as a case study. OSCC is the most common malignancy affecting the oral cavity. Investigation of biomarkers with potential prognostic utility is an active area of research in OSCC. The methods discussed here should be useful for designing quality search filters in similar domains. The authors searched MEDLINE for prognostic studies of OSCC, developed annotation guidelines for screeners, ran three calibration trials before annotating the remaining body of citations, and measured inter-annotator agreement (IAA). We retrieved 1,818 citations. After calibration, we screened the remaining citations (n = 1,767; 97.2%); IAA was substantial (kappa = 0.76). The dataset has 497 (27.3%) citations representing OSCC studies of potential prognostic biomarkers. The gold standard dataset is likely to be high quality and useful for future development and evaluation of filters for OSCC studies of potential prognostic biomarkers. The methodology we used is generalizable to other domains requiring a reference standard to evaluate the performance of search filters. A gold standard is essential because the labels regarding relevance enable computation of diagnostic metrics, such as sensitivity and specificity. Librarians and informationists with data analysis skills could contribute to developing gold standard datasets and subsequent filters tuned for their patrons' domains of interest.

  13. A Meta-Analysis of Typhoid Diagnostic Accuracy Studies: A Recommendation to Adopt a Standardized Composite Reference

    PubMed Central

    Storey, Helen L.; Huang, Ying; Crudder, Chris; Golden, Allison; de los Santos, Tala; Hawkins, Kenneth

    2015-01-01

    Novel typhoid diagnostics currently under development have the potential to improve clinical care, surveillance, and the disease burden estimates that support vaccine introduction. Blood culture is most often used as the reference method to evaluate the accuracy of new typhoid tests; however, it is recognized to be an imperfect gold standard. If no single gold standard test exists, use of a composite reference standard (CRS) can improve estimation of diagnostic accuracy. Numerous studies have used a CRS to evaluate new typhoid diagnostics; however, there is no consensus on an appropriate CRS. In order to evaluate existing tests for use as a reference test or inclusion in a CRS, we performed a systematic review of the typhoid literature to include all index/reference test combinations observed. We described the landscape of comparisons performed, showed results of a meta-analysis on the accuracy of the more common combinations, and evaluated sources of variability based on study quality. This wide-ranging meta-analysis suggests that no single test has sufficiently good performance but some existing diagnostics may be useful as part of a CRS. Additionally, based on findings from the meta-analysis and a constructed numerical example demonstrating the use of CRS, we proposed necessary criteria and potential components of a typhoid CRS to guide future recommendations. Agreement and adoption by all investigators of a standardized CRS is requisite, and would improve comparison of new diagnostics across independent studies, leading to the identification of a better reference test and improved confidence in prevalence estimates. PMID:26566275

  14. Glucose Measurement: Time for a Gold Standard

    PubMed Central

    Hagvik, Joakim

    2007-01-01

    There is no internationally recognized reference method for the measurement of blood glucose. The Centers for Disease Control and Prevention (CDC) highlighted the need for standardization some years ago when a project was started. The project objectives were to (1) investigate whether there are significant differences in calibration levels among currently used glucose monitors for home use and (2) develop a reference method for glucose determination. A first study confirmed the assumption that currently used home-use monitors differ significantly and that standardization is necessary in order to minimize variability and to improve patient care. As a reference method, CDC recommended a method based on isotope dilution gas chromatography–mass spectrometry, an assay that has received support from clinical chemists worldwide. CDC initiated a preliminary study to establish the suitability of this method, but then the project came to a halt. It is hoped that CDC, with support from the industry, as well as academic and professional organizations such as the American Association for Clinical Chemistry and International Federation of Clinical Chemistry and Laboratory Medicine, will be able to finalize the project and develop the long-awaited and much needed “gold standard” for glucose measurement. PMID:19888402

  15. Validation of diabetes mellitus and hypertension diagnosis in computerized medical records in primary health care

    PubMed Central

    2011-01-01

    Background Computerized Clinical Records, which are incorporated in primary health care practice, have great potential for research. In order to use this information, data quality and reliability must be assessed to prevent compromising the validity of the results. The aim of this study is to validate the diagnosis of hypertension and diabetes mellitus in the computerized clinical records of primary health care, taking the diagnosis criteria established in the most prominently used clinical guidelines as the gold standard against which what measure the sensitivity, specificity, and determine the predictive values. The gold standard for diabetes mellitus was the diagnostic criteria established in 2003 American Diabetes Association Consensus Statement for diabetic subjects. The gold standard for hypertension was the diagnostic criteria established in the Joint National Committee published in 2003. Methods A cross-sectional multicentre validation study of diabetes mellitus and hypertension diagnoses in computerized clinical records of primary health care was carried out. Diagnostic criteria from the most prominently clinical practice guidelines were considered for standard reference. Sensitivity, specificity, positive and negative predictive values, and global agreement (with kappa index), were calculated. Results were shown overall and stratified by sex and age groups. Results The agreement for diabetes mellitus with the reference standard as determined by the guideline was almost perfect (κ = 0.990), with a sensitivity of 99.53%, a specificity of 99.49%, a positive predictive value of 91.23% and a negative predictive value of 99.98%. Hypertension diagnosis showed substantial agreement with the reference standard as determined by the guideline (κ = 0.778), the sensitivity was 85.22%, the specificity 96.95%, the positive predictive value 85.24%, and the negative predictive value was 96.95%. Sensitivity results were worse in patients who also had diabetes and in those aged 70 years or over. Conclusions Our results substantiate the validity of using diagnoses of diabetes and hypertension found within the computerized clinical records for epidemiologic studies. PMID:22035202

  16. In vitro vaccine potency testing: a proposal for reducing animal use for requalification testing.

    PubMed

    Brown, K; Stokes, W

    2012-01-01

    This paper proposes a program under which the use of animals for requalification of in vitro potency tests could be eliminated. Standard References (USDA/CVB nomenclature) would be developed, characterized, stored and monitored by selected reference laboratories worldwide. These laboratories would employ scientists skilled in protein and glycoprotein chemistry and equipped with state-of-the-art instruments for required analyses. After Standard References are established, the reference laboratories would provide them to the animal health industry as "gold standards". Companies would then establish and validate a correlation between the Standard Reference and the company Master Reference (USDA/CVB nomenclature) using an internal in vitro assay. After this correlation is established, the company could use the Standard References for qualifying, monitoring and requalifying company Master References without the use of animals. Such a program would eliminate the need for animals for requalification of Master References and the need for each company to develop and validate a battery of Master Reference Monitoring assays. It would also provide advantages in terms of reduced costs and reduced time for requalification testing. As such it would provide a strong incentive for companies to develop and use in vitro assays for potency testing.

  17. Results of the National CT Colonography Trial: Questions and Answers

    Cancer.gov

    Learn the results of the National Computerized Tomographic Colonography (CTC) clinical trial, which evaluated how well CTC identifies participants with at least one significantly large polyp using colonoscopy as the gold (or reference) standard.

  18. Rational design of gold nanoparticle toxicology assays: a question of exposure scenario, dose and experimental setup.

    PubMed

    Taylor, Ulrike; Rehbock, Christoph; Streich, Carmen; Rath, Detlef; Barcikowski, Stephan

    2014-09-01

    Many studies have evaluated the toxicity of gold nanoparticles, although reliable predictions based on these results are rare. In order to overcome this problem, this article highlights strategies to improve comparability and standardization of nanotoxicological studies. To this end, it is proposed that we should adapt the nanomaterial to the addressed exposure scenario, using ligand-free nanoparticle references in order to differentiate ligand effects from size effects. Furthermore, surface-weighted particle dosing referenced to the biologically relevant parameter (e.g., cell number or organ mass) is proposed as the gold standard. In addition, it is recommended that we should shift the focus of toxicological experiments from 'live-dead' assays to the assessment of cell function, as this strategy allows observation of bioresponses at lower doses that are more relevant for in vivo scenarios.

  19. Rationale and design of the dual-energy computed tomography for ischemia determination compared to "gold standard" non-invasive and invasive techniques (DECIDE-Gold): A multicenter international efficacy diagnostic study of rest-stress dual-energy computed tomography angiography with perfusion.

    PubMed

    Truong, Quynh A; Knaapen, Paul; Pontone, Gianluca; Andreini, Daniele; Leipsic, Jonathon; Carrascosa, Patricia; Lu, Bin; Branch, Kelley; Raman, Subha; Bloom, Stephen; Min, James K

    2015-10-01

    Dual-energy CT (DECT) has potential to improve myocardial perfusion for physiologic assessment of coronary artery disease (CAD). Diagnostic performance of rest-stress DECT perfusion (DECTP) is unknown. DECIDE-Gold is a prospective multicenter study to evaluate the accuracy of DECT to detect hemodynamic (HD) significant CAD, as compared to fractional flow reserve (FFR) as a reference standard. Eligible participants are subjects with symptoms of CAD referred for invasive coronary angiography (ICA). Participants will undergo DECTP, which will be performed by pharmacological stress, and participants will subsequently proceed to ICA and FFR. HD-significant CAD will be defined as FFR ≤ 0.80. In those undergoing myocardial stress imaging (MPI) by positron emission tomography (PET), single photon emission computed tomography (SPECT) or cardiac magnetic resonance (CMR) imaging, ischemia will be graded by % ischemic myocardium. Blinded core laboratory interpretation will be performed for CCTA, DECTP, MPI, ICA, and FFR. Primary endpoint is accuracy of DECTP to detect ≥1 HD-significant stenosis at the subject level when compared to FFR. Secondary and tertiary endpoints are accuracies of combinations of DECTP at the subject and vessel levels compared to FFR and MPI. DECIDE-Gold will determine the performance of DECTP for diagnosing ischemia.

  20. Reference equation for prediction of a total distance during six-minute walk test using Indonesian anthropometrics.

    PubMed

    Nusdwinuringtyas, Nury; Widjajalaksmi; Yunus, Faisal; Alwi, Idrus

    2014-04-01

    to develop a reference equation for prediction of the total distance walk using Indonesian anthropometrics of sedentary healthy subjects. Subsequently, the prediction obtained was compared to those calculated by the Caucasian-based Enright prediction equation. the cross-sectional study was conducted among 123 healthy Indonesian adults with sedentary life style (58 male and 65 female subjects in an age range between 18 and 50 years). Heart rate was recorded using Polar with expectation in the sub-maximal zone (120-170 beats per minute). The subjects performed two six-minute walk tests, the first one on a 15-meter track according to the protocol developed by the investigator. The second walk was carried out on Biodex®gait trainer as gold standard. an average total distance of 547±54.24 m was found, not significantly different from the gold standard of 544.72±54.11 m (p>0.05). Multiple regression analysis was performed to develop the new equation. the reference equation for prediction of the total distance using Indonesian anthropometrics is more applicable in Indonesia.

  1. A multilingual gold-standard corpus for biomedical concept recognition: the Mantra GSC

    PubMed Central

    Clematide, Simon; Akhondi, Saber A; van Mulligen, Erik M; Rebholz-Schuhmann, Dietrich

    2015-01-01

    Objective To create a multilingual gold-standard corpus for biomedical concept recognition. Materials and methods We selected text units from different parallel corpora (Medline abstract titles, drug labels, biomedical patent claims) in English, French, German, Spanish, and Dutch. Three annotators per language independently annotated the biomedical concepts, based on a subset of the Unified Medical Language System and covering a wide range of semantic groups. To reduce the annotation workload, automatically generated preannotations were provided. Individual annotations were automatically harmonized and then adjudicated, and cross-language consistency checks were carried out to arrive at the final annotations. Results The number of final annotations was 5530. Inter-annotator agreement scores indicate good agreement (median F-score 0.79), and are similar to those between individual annotators and the gold standard. The automatically generated harmonized annotation set for each language performed equally well as the best annotator for that language. Discussion The use of automatic preannotations, harmonized annotations, and parallel corpora helped to keep the manual annotation efforts manageable. The inter-annotator agreement scores provide a reference standard for gauging the performance of automatic annotation techniques. Conclusion To our knowledge, this is the first gold-standard corpus for biomedical concept recognition in languages other than English. Other distinguishing features are the wide variety of semantic groups that are being covered, and the diversity of text genres that were annotated. PMID:25948699

  2. Biometry and intraocular lens power calculation results with a new optical biometry device: comparison with the gold standard.

    PubMed

    Kaswin, Godefroy; Rousseau, Antoine; Mgarrech, Mohamed; Barreau, Emmanuel; Labetoulle, Marc

    2014-04-01

    To evaluate the agreement in axial length (AL), keratometry (K), anterior chamber depth (ACD) measurements; intraocular lens (IOL) power calculations; and predictability using a new partial coherence interferometry (PCI) optical biometer (AL-Scan) and a reference (gold standard) PCI optical biometer (IOLMaster 500). Service d'Ophtalmologie, Hopital Bicêtre, APHP Université, Paris, France. Evaluation of a diagnostic device. One eye of consecutive patients scheduled for cataract surgery was measured. Biometry was performed with the new biometer and the reference biometer. Comparisons were performed for AL, average K at 2.4 mm, ACD, IOL power calculations with the Haigis and SRK/T formulas, and postoperative predictability of the devices. A P value less than 0.05 was statistically significant. The study enrolled 50 patients (mean age 72.6 years±4.2 SEM). There was a good correlation between biometers for AL, K, and ACD measurements (r=0.999, r=0.933, and r=0.701, respectively) and between IOL power calculation with the Haigis formula (r=0.972) and the SRK/T formula (r=0.981). The mean absolute error (MAE) in IOL power prediction was 0.42±0.08 diopter (D) with the new biometer and 0.44±0.08 D with the reference biometer. The MAE was 0.20 D with the Haigis formula and 0.19 with the SRK/T formula (P=.36). The new PCI biometer provided valid measurements compared with the current gold standard, indicating that the new device can be used for IOL power calculations for routine cataract surgery. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  3. A multilingual gold-standard corpus for biomedical concept recognition: the Mantra GSC.

    PubMed

    Kors, Jan A; Clematide, Simon; Akhondi, Saber A; van Mulligen, Erik M; Rebholz-Schuhmann, Dietrich

    2015-09-01

    To create a multilingual gold-standard corpus for biomedical concept recognition. We selected text units from different parallel corpora (Medline abstract titles, drug labels, biomedical patent claims) in English, French, German, Spanish, and Dutch. Three annotators per language independently annotated the biomedical concepts, based on a subset of the Unified Medical Language System and covering a wide range of semantic groups. To reduce the annotation workload, automatically generated preannotations were provided. Individual annotations were automatically harmonized and then adjudicated, and cross-language consistency checks were carried out to arrive at the final annotations. The number of final annotations was 5530. Inter-annotator agreement scores indicate good agreement (median F-score 0.79), and are similar to those between individual annotators and the gold standard. The automatically generated harmonized annotation set for each language performed equally well as the best annotator for that language. The use of automatic preannotations, harmonized annotations, and parallel corpora helped to keep the manual annotation efforts manageable. The inter-annotator agreement scores provide a reference standard for gauging the performance of automatic annotation techniques. To our knowledge, this is the first gold-standard corpus for biomedical concept recognition in languages other than English. Other distinguishing features are the wide variety of semantic groups that are being covered, and the diversity of text genres that were annotated. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association.

  4. Scattering resonances in bimolecular collisions between NO radicals and H2 challenge the theoretical gold standard

    NASA Astrophysics Data System (ADS)

    Vogels, Sjoerd N.; Karman, Tijs; Kłos, Jacek; Besemer, Matthieu; Onvlee, Jolijn; van der Avoird, Ad; Groenenboom, Gerrit C.; van de Meerakker, Sebastiaan Y. T.

    2018-02-01

    Over the last 25 years, the formalism known as coupled-cluster (CC) theory has emerged as the method of choice for the ab initio calculation of intermolecular interaction potentials. The implementation known as CCSD(T) is often referred to as the gold standard in quantum chemistry. It gives excellent agreement with experimental observations for a variety of energy-transfer processes in molecular collisions, and it is used to calibrate density functional theory. Here, we present measurements of low-energy collisions between NO radicals and H2 molecules with a resolution that challenges the most sophisticated quantum chemistry calculations at the CCSD(T) level. Using hitherto-unexplored anti-seeding techniques to reduce the collision energy in a crossed-beam inelastic-scattering experiment, a resonance structure near 14 cm-1 is clearly resolved in the state-to-state integral cross-section, and a unique resonance fingerprint is observed in the corresponding differential cross-section. This resonance structure discriminates between two NO-H2 potentials calculated at the CCSD(T) level and pushes the required accuracy beyond the gold standard.

  5. A Partnership for Public Health: USDA Branded Food Products Database

    USDA-ARS?s Scientific Manuscript database

    The importance of comprehensive food composition databases is more critical than ever in helping to address global food security. The USDA National Nutrient Database for Standard Reference is the “gold standard” for food composition databases. The presentation will include new developments in stren...

  6. Solid sampling high-resolution continuum source graphite furnace atomic absorption spectrometry for gold determination in geological samples after preconcentration onto carbon nanotubes

    NASA Astrophysics Data System (ADS)

    Dobrowolski, Ryszard; Mróz, Agnieszka; Dąbrowska, Marzena; Olszański, Piotr

    2017-06-01

    A novelty method for the determination of gold in geological samples by solid sampling high-resolution continuum source graphite furnace atomic absorption spectrometry (SS HR CS GF AAS) after solid-phase extraction onto modified carbon nanotubes (CNT) was described. The methodology developed is based on solid phase extraction of Au(III) ions from digested samples to eliminate strong interference caused by iron compounds and problems related to inhomogeneities of the samples. The use of aqueous or solid standard for calibration was studied and the slope of calibration curve was the same for both of these modes. This statement indicates the possibility to perform the calibration of the method using aqueous standard solutions. Under optimum conditions the absolute detection limit for gold was equal to 2.24 · 10- 6 μg g- 1 while the adsorption capacity of modified carbon nanotubes was 264 mg g- 1. The proposed procedure was validated by the application of certified reference materials (CRMs) with different content of gold and different matrix, the results were in good agreement with certified values. The method was successfully applied for separation and determination of gold ions in complex geological samples, with precision generally better than 8%.

  7. Accuracy of Referring Provider and Endoscopist Impressions of Colonoscopy Indication.

    PubMed

    Naveed, Mariam; Clary, Meredith; Ahn, Chul; Kubiliun, Nisa; Agrawal, Deepak; Cryer, Byron; Murphy, Caitlin; Singal, Amit G

    2017-07-01

    Background: Referring provider and endoscopist impressions of colonoscopy indication are used for clinical care, reimbursement, and quality reporting decisions; however, the accuracy of these impressions is unknown. This study assessed the sensitivity, specificity, positive and negative predictive value, and overall accuracy of methods to classify colonoscopy indication, including referring provider impression, endoscopist impression, and administrative algorithm compared with gold standard chart review. Methods: We randomly sampled 400 patients undergoing a colonoscopy at a Veterans Affairs health system between January 2010 and December 2010. Referring provider and endoscopist impressions of colonoscopy indication were compared with gold-standard chart review. Indications were classified into 4 mutually exclusive categories: diagnostic, surveillance, high-risk screening, or average-risk screening. Results: Of 400 colonoscopies, 26% were performed for average-risk screening, 7% for high-risk screening, 26% for surveillance, and 41% for diagnostic indications. Accuracy of referring provider and endoscopist impressions of colonoscopy indication were 87% and 84%, respectively, which were significantly higher than that of the administrative algorithm (45%; P <.001 for both). There was substantial agreement between endoscopist and referring provider impressions (κ=0.76). All 3 methods showed high sensitivity (>90%) for determining screening (vs nonscreening) indication, but specificity of the administrative algorithm was lower (40.3%) compared with referring provider (93.7%) and endoscopist (84.0%) impressions. Accuracy of endoscopist, but not referring provider, impression was lower in patients with a family history of colon cancer than in those without (65% vs 84%; P =.001). Conclusions: Referring provider and endoscopist impressions of colonoscopy indication are both accurate and may be useful data to incorporate into algorithms classifying colonoscopy indication. Copyright © 2017 by the National Comprehensive Cancer Network.

  8. Automated clinical trial eligibility prescreening: increasing the efficiency of patient identification for clinical trials in the emergency department

    PubMed Central

    Ni, Yizhao; Kennebeck, Stephanie; Dexheimer, Judith W; McAneney, Constance M; Tang, Huaxiu; Lingren, Todd; Li, Qi; Zhai, Haijun; Solti, Imre

    2015-01-01

    Objectives (1) To develop an automated eligibility screening (ES) approach for clinical trials in an urban tertiary care pediatric emergency department (ED); (2) to assess the effectiveness of natural language processing (NLP), information extraction (IE), and machine learning (ML) techniques on real-world clinical data and trials. Data and methods We collected eligibility criteria for 13 randomly selected, disease-specific clinical trials actively enrolling patients between January 1, 2010 and August 31, 2012. In parallel, we retrospectively selected data fields including demographics, laboratory data, and clinical notes from the electronic health record (EHR) to represent profiles of all 202795 patients visiting the ED during the same period. Leveraging NLP, IE, and ML technologies, the automated ES algorithms identified patients whose profiles matched the trial criteria to reduce the pool of candidates for staff screening. The performance was validated on both a physician-generated gold standard of trial–patient matches and a reference standard of historical trial–patient enrollment decisions, where workload, mean average precision (MAP), and recall were assessed. Results Compared with the case without automation, the workload with automated ES was reduced by 92% on the gold standard set, with a MAP of 62.9%. The automated ES achieved a 450% increase in trial screening efficiency. The findings on the gold standard set were confirmed by large-scale evaluation on the reference set of trial–patient matches. Discussion and conclusion By exploiting the text of trial criteria and the content of EHRs, we demonstrated that NLP-, IE-, and ML-based automated ES could successfully identify patients for clinical trials. PMID:25030032

  9. Assessing FDG-PET diagnostic accuracy studies to develop recommendations for clinical use in dementia.

    PubMed

    Boccardi, Marina; Festari, Cristina; Altomare, Daniele; Gandolfo, Federica; Orini, Stefania; Nobili, Flavio; Frisoni, Giovanni B

    2018-04-30

    FDG-PET is frequently used as a marker of synaptic damage to diagnose dementing neurodegenerative disorders. We aimed to adapt the items of evidence quality to FDG-PET diagnostic studies, and assess the evidence available in current literature to assist Delphi decisions for European recommendations for clinical use. Based on acknowledged methodological guidance, we defined the domains, specific to FDG-PET, required to assess the quality of evidence in 21 literature searches addressing as many Population Intervention Comparison Outcome (PICO) questions. We ranked findings for each PICO and fed experts making Delphi decisions for recommending clinical use. Among the 1435 retrieved studies, most lacked validated measures of test performance, an adequate gold standard, and head-to-head comparison of FDG-PET and clinical diagnosis, and only 58 entered detailed assessment. Only two studies assessed the accuracy of the comparator (clinical diagnosis) versus any kind of gold-/reference-standard. As to the index-test (FDG-PET-based diagnosis), an independent gold-standard was available in 24% of the examined papers; 38% used an acceptable reference-standard (clinical follow-up); and 38% compared FDG-PET-based diagnosis only to baseline clinical diagnosis. These methodological limitations did not allow for deriving recommendations from evidence. An incremental diagnostic value of FDG-PET versus clinical diagnosis or lack thereof cannot be derived from the current literature. Many of the observed limitations may easily be overcome, and we outlined them as research priorities to improve the quality of current evidence. Such improvement is necessary to outline evidence-based guidelines. The available data were anyway provided to expert clinicians who defined interim recommendations.

  10. A studentized permutation test for three-arm trials in the 'gold standard' design.

    PubMed

    Mütze, Tobias; Konietschke, Frank; Munk, Axel; Friede, Tim

    2017-03-15

    The 'gold standard' design for three-arm trials refers to trials with an active control and a placebo control in addition to the experimental treatment group. This trial design is recommended when being ethically justifiable and it allows the simultaneous comparison of experimental treatment, active control, and placebo. Parametric testing methods have been studied plentifully over the past years. However, these methods often tend to be liberal or conservative when distributional assumptions are not met particularly with small sample sizes. In this article, we introduce a studentized permutation test for testing non-inferiority and superiority of the experimental treatment compared with the active control in three-arm trials in the 'gold standard' design. The performance of the studentized permutation test for finite sample sizes is assessed in a Monte Carlo simulation study under various parameter constellations. Emphasis is put on whether the studentized permutation test meets the target significance level. For comparison purposes, commonly used Wald-type tests, which do not make any distributional assumptions, are included in the simulation study. The simulation study shows that the presented studentized permutation test for assessing non-inferiority in three-arm trials in the 'gold standard' design outperforms its competitors, for instance the test based on a quasi-Poisson model, for count data. The methods discussed in this paper are implemented in the R package ThreeArmedTrials which is available on the comprehensive R archive network (CRAN). Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  11. Assessing the Mechanisms of MDS and Its Transformation to Leukemia in a Novel Humanized Mouse

    DTIC Science & Technology

    2016-05-01

    achievements N/A References N/A References: 1. Rongvaux, A., et al., Development and function of human innate immune cells in a...in cancer survivors. MDS is inherently difficult to study. MDS stem cells cannot be grown in culture and in vivo models are thus the gold standard...However, MDS stem cells are diseased and fail to efficiently engraft in current immunodeficient mouse models. We have optimized engraftment of

  12. Curricular Innovation in an Undergraduate Medical Program: What Is "Appropriate" Assessment?

    ERIC Educational Resources Information Center

    Ruhe, Valerie; Boudreau, J. Donald

    2011-01-01

    In post-secondary education, there is a widely-held belief in a "gold standard" for evaluative studies of curricular innovations. In this context, "appropriate" assessment is understood to refer to experimental designs and statistically significant differences in group outcomes. Yet in our evaluative study of a medical undergraduate program, we…

  13. A reference standard for bidirectional reflection distribution function and bidirectional transmission distribution function measurement

    NASA Technical Reports Server (NTRS)

    Witherow, William K. (Inventor)

    1988-01-01

    A Lambertian reference standard for uniformly scattering a beam of light is constructed of a plate having a planar surface with a layer of glue disposed on the surface. An evenly packed layer of monodisperse spheres is set in the layer, and when the standard is used for bi-directional (BRDF) measurements, the spheres are coated with a layer of highly relective substance, such as gold or silver. When the standard is used for bi-directional transmittance distribution function (BTDF) measurements, the spheres are of a transparent material and are provided with a roughened surface, as by acid etching. In this case, the layer of glue is an optical cement, and the plate is of glass, with the spheres, the layer, and the plate all possessing a similar refractive index.

  14. Reference standard space hippocampus labels according to the European Alzheimer's Disease Consortium-Alzheimer's Disease Neuroimaging Initiative harmonized protocol: Utility in automated volumetry.

    PubMed

    Wolf, Dominik; Bocchetta, Martina; Preboske, Gregory M; Boccardi, Marina; Grothe, Michel J

    2017-08-01

    A harmonized protocol (HarP) for manual hippocampal segmentation on magnetic resonance imaging (MRI) has recently been developed by an international European Alzheimer's Disease Consortium-Alzheimer's Disease Neuroimaging Initiative project. We aimed at providing consensual certified HarP hippocampal labels in Montreal Neurological Institute (MNI) standard space to serve as reference in automated image analyses. Manual HarP tracings on the high-resolution MNI152 standard space template of four expert certified HarP tracers were combined to obtain consensual bilateral hippocampus labels. Utility and validity of these reference labels is demonstrated in a simple atlas-based morphometry approach for automated calculation of HarP-compliant hippocampal volumes within SPM software. Individual tracings showed very high agreement among the four expert tracers (pairwise Jaccard indices 0.82-0.87). Automatically calculated hippocampal volumes were highly correlated (r L/R  = 0.89/0.91) with gold standard volumes in the HarP benchmark data set (N = 135 MRIs), with a mean volume difference of 9% (standard deviation 7%). The consensual HarP hippocampus labels in the MNI152 template can serve as a reference standard for automated image analyses involving MNI standard space normalization. Copyright © 2017 the Alzheimer's Association. Published by Elsevier Inc. All rights reserved.

  15. Post hoc interlaboratory comparison of single particle ICP-MS size measurements of NIST gold nanoparticle reference materials.

    PubMed

    Montoro Bustos, Antonio R; Petersen, Elijah J; Possolo, Antonio; Winchester, Michael R

    2015-09-01

    Single particle inductively coupled plasma-mass spectrometry (spICP-MS) is an emerging technique that enables simultaneous measurement of nanoparticle size and number quantification of metal-containing nanoparticles at realistic environmental exposure concentrations. Such measurements are needed to understand the potential environmental and human health risks of nanoparticles. Before spICP-MS can be considered a mature methodology, additional work is needed to standardize this technique including an assessment of the reliability and variability of size distribution measurements and the transferability of the technique among laboratories. This paper presents the first post hoc interlaboratory comparison study of the spICP-MS technique. Measurement results provided by six expert laboratories for two National Institute of Standards and Technology (NIST) gold nanoparticle reference materials (RM 8012 and RM 8013) were employed. The general agreement in particle size between spICP-MS measurements and measurements by six reference techniques demonstrates the reliability of spICP-MS and validates its sizing capability. However, the precision of the spICP-MS measurement was better for the larger 60 nm gold nanoparticles and evaluation of spICP-MS precision indicates substantial variability among laboratories, with lower variability between operators within laboratories. Global particle number concentration and Au mass concentration recovery were quantitative for RM 8013 but significantly lower and with a greater variability for RM 8012. Statistical analysis did not suggest an optimal dwell time, because this parameter did not significantly affect either the measured mean particle size or the ability to count nanoparticles. Finally, the spICP-MS data were often best fit with several single non-Gaussian distributions or mixtures of Gaussian distributions, rather than the more frequently used normal or log-normal distributions.

  16. Clinical Impact of Wordless Picture Storybooks on Bilingual Narrative Language Production: A Comparison of the "Frog" Stories

    ERIC Educational Resources Information Center

    Heilmann, John J.; Rojas, Raúl; Iglesias, Aquiles; Miller, Jon F.

    2016-01-01

    Background: Language sampling, recognized as a gold standard for expressive language assessment, is often elicited using wordless picture storybooks. A series of wordless storybooks, commonly referred to as "Frog" stories, have been frequently used in language-based research with children from around the globe. Aims: To examine the…

  17. Stress-only myocardial perfusion scintigraphy: a prospective study on the accuracy and observer agreement with quantitative coronary angiography as the gold standard.

    PubMed

    Ejlersen, June A; May, Ole; Mortensen, Jesper; Nielsen, Gitte L; Lauridsen, Jeppe F; Allan, Johansen

    2017-11-01

    Patients with normal stress perfusion have an excellent prognosis. Prospective studies on the diagnostic accuracy of stress-only scans with contemporary, independent examinations as gold standards are lacking. A total of 109 patients with typical angina and no previous coronary artery disease underwent a 2-day stress (exercise)/rest, gated, and attenuation-corrected (AC), 99m-technetium-sestamibi perfusion study, followed by invasive coronary angiography. The stress datasets were evaluated twice by four physicians with two different training levels (expert and novice): familiar and unfamiliar with AC. The two experts also made a consensus reading of the integrated stress-rest datasets. The consensus reading and quantitative data from the invasive coronary angiography were applied as reference methods. The sensitivity/specificity were 0.92-1.00/0.73-0.90 (reference: expert consensus reading), 0.93-0.96/0.63-0.82 (reference: ≥1 stenosis>70%), and 0.75-0.88/0.70-0.88 (reference: ≥1 stenosis>50%). The four readers showed a high and fairly equal sensitivity independent of their familiarity with AC. The expert familiar with AC had the highest specificity independent of the reference method. The intraobserver and interobserver agreements on the stress-only readings were good (readers without AC experience) to excellent (readers with AC experience). AC stress-only images yielded a high sensitivity independent of the training level and experience with AC of the nuclear physician, whereas the specificity correlated positively with both. Interobserver and intraobserver agreements tended to be the best for physicians with AC experience.

  18. High resolution microendoscopy for early detection of esophageal cancer in low-resource settings (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Richards-Kortum, Rebecca

    2016-03-01

    Esophageal squamous cell neoplasia (ESCN) is the sixth leading cause of cancer death worldwide. Most deaths due to ESCN occur in developing countries, with highest risk areas in northern China. Lugol's chromoendoscopy (LCE) is the gold-standard for ESCN screening; while the sensitivity of LCE for ESCN is >95%, LCE suffers poor specificity (< 65%) due to false positive findings from inflammatory lesions. High resolution microendoscopy (HRME) uses a low-cost, fiber-optic fluorescence microscope to image morphology of the surface epithelium without need for biopsy. We developed a tablet-interfaced HRME with automated, real-time image analysis. In an in vivo study of 177 patients referred for endoscopy in China, use of the algorithm identified neoplasia with a sensitivity and specificity of 95% and 91% compared to the gold standard of histology.

  19. Automated Spatial Brain Normalization and Hindbrain White Matter Reference Tissue Give Improved [(18)F]-Florbetaben PET Quantitation in Alzheimer's Model Mice.

    PubMed

    Overhoff, Felix; Brendel, Matthias; Jaworska, Anna; Korzhova, Viktoria; Delker, Andreas; Probst, Federico; Focke, Carola; Gildehaus, Franz-Josef; Carlsen, Janette; Baumann, Karlheinz; Haass, Christian; Bartenstein, Peter; Herms, Jochen; Rominger, Axel

    2016-01-01

    Preclinical PET studies of β-amyloid (Aβ) accumulation are of growing importance, but comparisons between research sites require standardized and optimized methods for quantitation. Therefore, we aimed to evaluate systematically the (1) impact of an automated algorithm for spatial brain normalization, and (2) intensity scaling methods of different reference regions for Aβ-PET in a large dataset of transgenic mice. PS2APP mice in a 6 week longitudinal setting (N = 37) and another set of PS2APP mice at a histologically assessed narrow range of Aβ burden (N = 40) were investigated by [(18)F]-florbetaben PET. Manual spatial normalization by three readers at different training levels was performed prior to application of an automated brain spatial normalization and inter-reader agreement was assessed by Fleiss Kappa (κ). For this method the impact of templates at different pathology stages was investigated. Four different reference regions on brain uptake normalization were used to calculate frontal cortical standardized uptake value ratios (SUVRCTX∕REF), relative to raw SUVCTX. Results were compared on the basis of longitudinal stability (Cohen's d), and in reference to gold standard histopathological quantitation (Pearson's R). Application of an automated brain spatial normalization resulted in nearly perfect agreement (all κ≥0.99) between different readers, with constant or improved correlation with histology. Templates based on inappropriate pathology stage resulted in up to 2.9% systematic bias for SUVRCTX∕REF. All SUVRCTX∕REF methods performed better than SUVCTX both with regard to longitudinal stability (d≥1.21 vs. d = 0.23) and histological gold standard agreement (R≥0.66 vs. R≥0.31). Voxel-wise analysis suggested a physiologically implausible longitudinal decrease by global mean scaling. The hindbrain white matter reference (R mean = 0.75) was slightly superior to the brainstem (R mean = 0.74) and the cerebellum (R mean = 0.73). Automated brain normalization with reference region templates presents an excellent method to avoid the inter-reader variability in preclinical Aβ-PET scans. Intracerebral reference regions lacking Aβ pathology serve for precise longitudinal in vivo quantification of [(18)F]-florbetaben PET. Hindbrain white matter reference performed best when considering the composite of quality criteria.

  20. Quantitative Rapid Assessment of Leukoaraiosis in CT : Comparison to Gold Standard MRI.

    PubMed

    Hanning, Uta; Sporns, Peter Bernhard; Schmidt, Rene; Niederstadt, Thomas; Minnerup, Jens; Bier, Georg; Knecht, Stefan; Kemmling, André

    2017-10-20

    The severity of white matter lesions (WML) is a risk factor of hemorrhage and predictor of clinical outcome after ischemic stroke; however, in contrast to magnetic resonance imaging (MRI) reliable quantification for this surrogate marker is limited for computed tomography (CT), the leading stroke imaging technique. We aimed to present and evaluate a CT-based automated rater-independent method for quantification of microangiopathic white matter changes. Patients with suspected minor stroke (National Institutes of Health Stroke scale, NIHSS < 4) were screened for the analysis of non-contrast computerized tomography (NCCT) at admission and compared to follow-up MRI. The MRI-based WML volume and visual Fazekas scores were assessed as the gold standard reference. We employed a recently published probabilistic brain segmentation algorithm for CT images to determine the tissue-specific density of WM space. All voxel-wise densities were quantified in WM space and weighted according to partial probabilistic WM content. The resulting mean weighted density of WM space in NCCT, the surrogate of WML, was correlated with reference to MRI-based WML parameters. The process of CT-based tissue-specific segmentation was reliable in 79 cases with varying severity of microangiopathy. Voxel-wise weighted density within WM spaces showed a noticeable correlation (r = -0.65) with MRI-based WML volume. Particularly in patients with moderate or severe lesion load according to the visual Fazekas score the algorithm provided reliable prediction of MRI-based WML volume. Automated observer-independent quantification of voxel-wise WM density in CT significantly correlates with microangiopathic WM disease in gold standard MRI. This rapid surrogate of white matter lesion load in CT may support objective WML assessment and therapeutic decision-making during acute stroke triage.

  1. Partial verification bias and incorporation bias affected accuracy estimates of diagnostic studies for biomarkers that were part of an existing composite gold standard.

    PubMed

    Karch, Annika; Koch, Armin; Zapf, Antonia; Zerr, Inga; Karch, André

    2016-10-01

    To investigate how choice of gold standard biases estimates of sensitivity and specificity in studies reassessing the diagnostic accuracy of biomarkers that are already part of a lifetime composite gold standard (CGS). We performed a simulation study based on the real-life example of the biomarker "protein 14-3-3" used for diagnosing Creutzfeldt-Jakob disease. Three different types of gold standard were compared: perfect gold standard "autopsy" (available in a small fraction only; prone to partial verification bias), lifetime CGS (including the biomarker under investigation; prone to incorporation bias), and "best available" gold standard (autopsy if available, otherwise CGS). Sensitivity was unbiased when comparing 14-3-3 with autopsy but overestimated when using CGS or "best available" gold standard. Specificity of 14-3-3 was underestimated in scenarios comparing 14-3-3 with autopsy (up to 24%). In contrast, overestimation (up to 20%) was observed for specificity compared with CGS; this could be reduced to 0-10% when using the "best available" gold standard. Choice of gold standard affects considerably estimates of diagnostic accuracy. Using the "best available" gold standard (autopsy where available, otherwise CGS) leads to valid estimates of specificity, whereas sensitivity is estimated best when tested against autopsy alone. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Using a high-dimensional graph of semantic space to model relationships among words

    PubMed Central

    Jackson, Alice F.; Bolger, Donald J.

    2014-01-01

    The GOLD model (Graph Of Language Distribution) is a network model constructed based on co-occurrence in a large corpus of natural language that may be used to explore what information may be present in a graph-structured model of language, and what information may be extracted through theoretically-driven algorithms as well as standard graph analysis methods. The present study will employ GOLD to examine two types of relationship between words: semantic similarity and associative relatedness. Semantic similarity refers to the degree of overlap in meaning between words, while associative relatedness refers to the degree to which two words occur in the same schematic context. It is expected that a graph structured model of language constructed based on co-occurrence should easily capture associative relatedness, because this type of relationship is thought to be present directly in lexical co-occurrence. However, it is hypothesized that semantic similarity may be extracted from the intersection of the set of first-order connections, because two words that are semantically similar may occupy similar thematic or syntactic roles across contexts and thus would co-occur lexically with the same set of nodes. Two versions the GOLD model that differed in terms of the co-occurence window, bigGOLD at the paragraph level and smallGOLD at the adjacent word level, were directly compared to the performance of a well-established distributional model, Latent Semantic Analysis (LSA). The superior performance of the GOLD models (big and small) suggest that a single acquisition and storage mechanism, namely co-occurrence, can account for associative and conceptual relationships between words and is more psychologically plausible than models using singular value decomposition (SVD). PMID:24860525

  3. Using a high-dimensional graph of semantic space to model relationships among words.

    PubMed

    Jackson, Alice F; Bolger, Donald J

    2014-01-01

    The GOLD model (Graph Of Language Distribution) is a network model constructed based on co-occurrence in a large corpus of natural language that may be used to explore what information may be present in a graph-structured model of language, and what information may be extracted through theoretically-driven algorithms as well as standard graph analysis methods. The present study will employ GOLD to examine two types of relationship between words: semantic similarity and associative relatedness. Semantic similarity refers to the degree of overlap in meaning between words, while associative relatedness refers to the degree to which two words occur in the same schematic context. It is expected that a graph structured model of language constructed based on co-occurrence should easily capture associative relatedness, because this type of relationship is thought to be present directly in lexical co-occurrence. However, it is hypothesized that semantic similarity may be extracted from the intersection of the set of first-order connections, because two words that are semantically similar may occupy similar thematic or syntactic roles across contexts and thus would co-occur lexically with the same set of nodes. Two versions the GOLD model that differed in terms of the co-occurence window, bigGOLD at the paragraph level and smallGOLD at the adjacent word level, were directly compared to the performance of a well-established distributional model, Latent Semantic Analysis (LSA). The superior performance of the GOLD models (big and small) suggest that a single acquisition and storage mechanism, namely co-occurrence, can account for associative and conceptual relationships between words and is more psychologically plausible than models using singular value decomposition (SVD).

  4. NIST gold nanoparticle reference materials do not induce oxidative DNA damage.

    PubMed

    Nelson, Bryant C; Petersen, Elijah J; Marquis, Bryce J; Atha, Donald H; Elliott, John T; Cleveland, Danielle; Watson, Stephanie S; Tseng, I-Hsiang; Dillon, Andrew; Theodore, Mellisa; Jackman, Joany

    2013-02-01

    One primary challenge in nanotoxicology studies is the lack of well-characterised nanoparticle reference materials which could be used as positive or negative nanoparticle controls. The National Institute of Standards and Technology (NIST) has developed three gold nanoparticle (AuNP) reference materials (10, 30 and 60 nm). The genotoxicity of these nanoparticles was tested using HepG2 cells and calf-thymus DNA. DNA damage was assessed based on the specific and sensitive measurement of four oxidatively-modified DNA lesions (8-hydroxy-2´-deoxyguanosine, 8-hydroxy-2´-deoxyadenosine, (5´S)-8,5´-cyclo-2´-deoxyadenosine and (5´R)-8,5´-cyclo-2´-deoxyadenosine) using liquid chromatography/tandem mass spectrometry. Significantly elevated, dose-dependent DNA damage was not detected at concentrations up to 0.2 μg/ml, and free radicals were not detected using electron paramagnetic resonance spectroscopy. These data suggest that the NIST AuNPs could potentially serve as suitable negative-control nanoparticle reference materials for in vitro and in vivo genotoxicity studies. NIST AuNPs thus hold substantial promise for improving the reproducibility and reliability of nanoparticle genotoxicity studies.

  5. Automated Assessment of Non-Native Learner Essays: Investigating the Role of Linguistic Features

    ERIC Educational Resources Information Center

    Vajjala, Sowmya

    2018-01-01

    Automatic essay scoring (AES) refers to the process of scoring free text responses to given prompts, considering human grader scores as the gold standard. Writing such essays is an essential component of many language and aptitude exams. Hence, AES became an active and established area of research, and there are many proprietary systems used in…

  6. Determination of mercury in ambient water samples by anodic stripping voltammetry on screen-printed gold electrodes.

    PubMed

    Bernalte, E; Marín Sánchez, C; Pinilla Gil, E

    2011-03-09

    The applicability of commercial screen-printed gold electrodes (SPGEs) for the determination of Hg(II) in ambient water samples by square wave anodic stripping voltammetry has been demonstrated. Electrode conditioning procedures, chemical and instrumental variables have been optimized to develop a reliable method capable of measuring dissolved mercury in the low ng mL(-1) range (detection limit 1.1 ng mL(-1)), useful for pollution monitoring or screening purposes. The proposed method was tested with the NIST 1641d Mercury in Water Standard Reference Material (recoveries 90.0-110%) and the NCS ZC 76303 Mercury in Water Certified Reference Material (recoveries 82.5-90.6%). Waste water samples from industrial origin and fortified rain water samples were assayed for mercury by the proposed method and by a reference ICP-MS method, with good agreement. Screen printing technology thus opens a useful way for the construction of reliable electrochemical sensors for decentralized or even field Hg(II) testing. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. Development and validation of a Pneumocystis jirovecii real-time polymerase chain reaction assay for diagnosis of Pneumocystis pneumonia

    PubMed Central

    Church, Deirdre L; Ambasta, Anshula; Wilmer, Amanda; Williscroft, Holly; Ritchie, Gordon; Pillai, Dylan R; Champagne, Sylvie; Gregson, Daniel G

    2015-01-01

    BACKGROUND: Pneumocystis jirovecii (PJ), a pathogenic fungus, causes severe interstitial Pneumocystis pneumonia (PCP) among immunocompromised patients. A laboratory-developed real-time polyermase chain reaction (PCR) assay was validated for PJ detection to improve diagnosis of PCP. METHODS: Forty stored bronchoalveolar lavage (BAL) samples (20 known PJ positive [PJ+] and 20 known PJ negative [PJ−]) were initially tested using the molecular assay. Ninety-two sequentially collected BAL samples were then analyzed using an immunofluorescence assay (IFA) and secondarily tested using the PJ real-time PCR assay. Discrepant results were resolved by retesting BAL samples using another real-time PCR assay with a different target. PJ real-time PCR assay performance was compared with the existing gold standard (ie, IFA) and a modified gold standard, in which a true positive was defined as a sample that tested positive in two of three methods in a patient suspected to have PCP. RESULTS: Ninety of 132 (68%) BAL fluid samples were collected from immunocompromised patients. Thirteen of 92 (14%) BALs collected were PJ+ when tested using IFA. A total of 40 BAL samples were PJ+ in the present study including: all IFA positive samples (n=13); all referred PJ+ BAL samples (n=20); and seven additional BAL samples that were IFA negative, but positive using the modified gold standard. Compared with IFA, the PJ real-time PCR had sensitivity, specificity, and positive and negative predictive values of 100%, 91%, 65% and 100%, respectively. Compared with the modified gold standard, PJ real-time PCR had a sensitivity, specificity, and positive and negative predictive values of 100%. CONCLUSION: PJ real-time PCR improved detection of PJ in immunocompromised patients. PMID:26600815

  8. Pitfalls in the measurement of muscle mass: a need for a reference standard

    PubMed Central

    Landi, Francesco; Cesari, Matteo; Fielding, Roger A.; Visser, Marjolein; Engelke, Klaus; Maggi, Stefania; Dennison, Elaine; Al‐Daghri, Nasser M.; Allepaerts, Sophie; Bauer, Jurgen; Bautmans, Ivan; Brandi, Maria Luisa; Bruyère, Olivier; Cederholm, Tommy; Cerreta, Francesca; Cherubini, Antonio; Cooper, Cyrus; Cruz‐Jentoft, Alphonso; McCloskey, Eugene; Dawson‐Hughes, Bess; Kaufman, Jean‐Marc; Laslop, Andrea; Petermans, Jean; Reginster, Jean‐Yves; Rizzoli, René; Robinson, Sian; Rolland, Yves; Rueda, Ricardo; Vellas, Bruno; Kanis, John A.

    2018-01-01

    Abstract Background All proposed definitions of sarcopenia include the measurement of muscle mass, but the techniques and threshold values used vary. Indeed, the literature does not establish consensus on the best technique for measuring lean body mass. Thus, the objective measurement of sarcopenia is hampered by limitations intrinsic to assessment tools. The aim of this study was to review the methods to assess muscle mass and to reach consensus on the development of a reference standard. Methods Literature reviews were performed by members of the European Society for Clinical and Economic Aspects of Osteoporosis and Osteoarthritis working group on frailty and sarcopenia. Face‐to‐face meetings were organized for the whole group to make amendments and discuss further recommendations. Results A wide range of techniques can be used to assess muscle mass. Cost, availability, and ease of use can determine whether the techniques are better suited to clinical practice or are more useful for research. No one technique subserves all requirements but dual energy X‐ray absorptiometry could be considered as a reference standard (but not a gold standard) for measuring muscle lean body mass. Conclusions Based on the feasibility, accuracy, safety, and low cost, dual energy X‐ray absorptiometry can be considered as the reference standard for measuring muscle mass. PMID:29349935

  9. Establishment of gold-quartz standard GQS-1

    USGS Publications Warehouse

    Millard, Hugh T.; Marinenko, John; McLane, John E.

    1969-01-01

    A homogeneous gold-quartz standard, GQS-1, was prepared from a heterogeneous gold-bearing quartz by chemical treatment. The concentration of gold in GQS-1 was determined by both instrumental neutron activation analysis and radioisotope dilution analysis to be 2.61?0.10 parts per million. Analysis of 10 samples of the standard by both instrumental neutron activation analysis and radioisotope dilution analysis failed to reveal heterogeneity within the standard. The precision of the analytical methods, expressed as standard error, was approximately 0.1 part per million. The analytical data were also used to estimate the average size of gold particles. The chemical treatment apparently reduced the average diameter of the gold particles by at least an order of magnitude and increased the concentration of gold grains by a factor of at least 4,000.

  10. Fully automated motion correction in first-pass myocardial perfusion MR image sequences.

    PubMed

    Milles, Julien; van der Geest, Rob J; Jerosch-Herold, Michael; Reiber, Johan H C; Lelieveldt, Boudewijn P F

    2008-11-01

    This paper presents a novel method for registration of cardiac perfusion magnetic resonance imaging (MRI). The presented method is capable of automatically registering perfusion data, using independent component analysis (ICA) to extract physiologically relevant features together with their time-intensity behavior. A time-varying reference image mimicking intensity changes in the data of interest is computed based on the results of that ICA. This reference image is used in a two-pass registration framework. Qualitative and quantitative validation of the method is carried out using 46 clinical quality, short-axis, perfusion MR datasets comprising 100 images each. Despite varying image quality and motion patterns in the evaluation set, validation of the method showed a reduction of the average right ventricle (LV) motion from 1.26+/-0.87 to 0.64+/-0.46 pixels. Time-intensity curves are also improved after registration with an average error reduced from 2.65+/-7.89% to 0.87+/-3.88% between registered data and manual gold standard. Comparison of clinically relevant parameters computed using registered data and the manual gold standard show a good agreement. Additional tests with a simulated free-breathing protocol showed robustness against considerable deviations from a standard breathing protocol. We conclude that this fully automatic ICA-based method shows an accuracy, a robustness and a computation speed adequate for use in a clinical environment.

  11. Beyond the Great Wall: gold of the silk roads and the first empire of the steppes.

    PubMed

    Radtke, Martin; Reiche, Ina; Reinholz, Uwe; Riesemeier, Heinrich; Guerra, Maria F

    2013-02-05

    Fingerprinting ancient gold work requires the use of nondestructive techniques with high spatial resolution (down to 25 μm) and good detection limits (micrograms per gram level). In this work experimental setups and protocols for synchrotron radiation induced X-ray fluorescence (SRXRF) at the BAMline of the Berlin electron storage ring company for synchrotron radiation (BESSY) in Berlin for the measurement of characteristic trace elements of gold are compared considering the difficulties, shown in previous works, connected to the quantification of Pt. The best experimental conditions and calculation methods were achieved by using an excitation energy of 11.58 keV, a silicon drift chamber detector (SDD) detector, and pure element reference standards. A detection limit of 3 μg/g has been reached. This newly developed method was successfully applied to provenancing the Xiongnu gold from the Gol Mod necropolis, excavated under the aegis of the United Nations Educational, Scientific and Cultural Organization (UNESCO). The composition of the base alloys and the presence of Pt and Sn showed that, contrary to what is expected, the gold foils from the first powerful empire of the steppes along the Great Wall were produced with alluvial gold from local placer deposits located in Zaamar, Boroo, and in the Selenga River.

  12. Quantiferon-TB Gold Plus is a More Sensitive Screening Tool than Quantiferon-TB Gold In-Tube for Latent Tuberculosis Infection among Older Adults in Long-Term Care Facility.

    PubMed

    Chien, Jung-Yien; Chiang, Hsiu-Tzy; Lu, Min-Chi; Ko, Wen-Chien; Yu, Chong-Jen; Chen, Yen-Hsu; Hsueh, Po-Ren

    2018-05-23

    We investigated the prevalence of latent tuberculosis infection (LTBI) among the residents in seven long-term care facilities (LTCFs) located in different regions of Taiwan and compared the performance of two interferon-gamma release assays, i.e. QuantiFERON-TB Gold In-Tube (QFT-GIT) and QuantiFERON-TB Gold plus (QFT-Plus) for screening LTBI. We also assessed the diagnostic performance against a composite reference standard (subjects with persistent-positive, transient-positive, and negative results of QFTs during reproducibility analysis were classified as definite, possible and not LTBI, respectively). Two hundred and forty-four residents were enrolled and 229 subjects were included into analysis. The median age was 80 years (range, 60-102 years old) and 117 (51.1%) were male. Among them, 66 (28.8%) and 74 (32.3%) subjects had positive results of QFT-GIT and QFT-Plus, respectively, and 215 (93.9%) subjects showed agreement results. Using composite reference standard, 66 (28.8%), 11 (4.8%), and 152 (66.4%) were classified as definite, possible and not LTBI, respectively. For definite LTBI, the sensitivity, specificity, positive predictive value, and negative predictive value of QFT-GIT were 89.4%, 95.7%, 89.4%, and 95.7%, respectively, and those for QFT-Plus were 100.0%, 95.1%, 89.2%, and 100.0%. The sensitivity of QFT-GIT decreased gradually with age. Compared to QFT-GIT, QFT-Plus displayed significantly higher sensitivity (100.0% vs. 89.4%, P =0.013) and similar specificity (95.1% vs. 95.7%). In conclusion, a high prevalence of LTBI was found among elders in LTCFs in Taiwan. The new QFT-Plus test demonstrated a higher sensitivity than QFT-GIT in the older adults in LTCFs. Copyright © 2018 American Society for Microbiology.

  13. Evaluation of the OnSite (Pf/Pan) rapid diagnostic test for diagnosis of clinical malaria.

    PubMed

    Mohon, Abu Naser; Elahi, Rubayet; Podder, Milka Patracia; Mohiuddin, Khaja; Hossain, Mohammad Sharif; Khan, Wasif A; Haque, Rashidul; Alam, Mohammad Shafiul

    2012-12-12

    Accurate diagnosis of malaria is an essential prerequisite for proper treatment and drug resistance monitoring. Microscopy is considered the gold standard for malaria diagnosis but has limitations. ELISA, PCR, and Real Time PCR are also used to diagnose malaria in reference laboratories, although their application at the field level is currently not feasible. Rapid diagnostic tests (RDTs) however, have been brought into field operation and widely adopted in recent days. This study evaluates OnSite (Pf/Pan) antigen test, a new RDT introduced by CTK Biotech Inc, USA for malaria diagnosis in a reference setting. Blood samples were collected from febrile patients referred for malaria diagnosis by clinicians. Subjects were included in this study from two different Upazila Health Complexes (UHCs) situated in two malaria endemic districts of Bangladesh. Microscopy and nested PCR were considered the gold standard in this study. OnSite (Pf/Pan) RDT was performed on preserved whole blood samples. In total, 372 febrile subjects were included in this study. Of these subjects, 229 (61.6%) tested positive for Plasmodium infection detected by microscopy and nested PCR. OnSite (Pf/Pan) RDT was 94.2% sensitive (95% CI, 89.3-97.3) and 99.5% specific (95% CI, 97.4-00.0) for Plasmodium falciparum diagnosis and 97.3% sensitive (95% CI, 90.5-99.7) and 98.7% specific (95% CI, 96.6-99.6) for Plasmodium vivax diagnosis. Sensitivity varied with differential parasite count for both P. falciparum and P. vivax. The highest sensitivity was observed in febrile patients with parasitaemia that ranged from 501-1,000 parasites/μL regardless of the Plasmodium species. The new OnSite (Pf/Pan) RDT is both sensitive and specific for symptomatic malaria diagnosis in standard laboratory conditions.

  14. Comparison of the diagnostic accuracy of a rapid immunochromatographic test and the rapid plasma reagin test for antenatal syphilis screening in Mozambique.

    PubMed Central

    Montoya, Pablo J.; Lukehart, Sheila A.; Brentlinger, Paula E.; Blanco, Ana J.; Floriano, Florencia; Sairosse, Josefa; Gloyd, Stephen

    2006-01-01

    OBJECTIVE: Programmes to control syphilis in developing countries are hampered by a lack of laboratory services, delayed diagnosis, and doubts about current screening methods. We aimed to compare the diagnostic accuracy of an immunochromatographic strip (ICS) test and the rapid plasma reagin (RPR) test with the combined gold standard (RPR, Treponema pallidum haemagglutination assay and direct immunofluorescence stain done at a reference laboratory) for the detection of syphilis in pregnancy. METHODS: We included test results from 4789 women attending their first antenatal visit at one of six health facilities in Sofala Province, central Mozambique. We compared diagnostic accuracy (sensitivity, specificity, and positive and negative predictive values) of ICS and RPR done at the health facilities and ICS performed at the reference laboratory. We also made subgroup comparisons by human immunodeficiency virus (HIV) and malaria status. FINDINGS: For active syphilis, the sensitivity of the ICS was 95.3% at the reference laboratory, and 84.1% at the health facility. The sensitivity of the RPR at the health facility was 70.7%. Specificity and positive and negative predictive values showed a similar pattern. The ICS outperformed RPR in all comparisons (P<0.001). CONCLUSION: The diagnostic accuracy of the ICS compared favourably with that of the gold standard. The use of the ICS in Mozambique and similar settings may improve the diagnosis of syphilis in health facilities, both with and without laboratories. PMID:16501726

  15. Pitfalls in the measurement of muscle mass: a need for a reference standard.

    PubMed

    Buckinx, Fanny; Landi, Francesco; Cesari, Matteo; Fielding, Roger A; Visser, Marjolein; Engelke, Klaus; Maggi, Stefania; Dennison, Elaine; Al-Daghri, Nasser M; Allepaerts, Sophie; Bauer, Jurgen; Bautmans, Ivan; Brandi, Maria Luisa; Bruyère, Olivier; Cederholm, Tommy; Cerreta, Francesca; Cherubini, Antonio; Cooper, Cyrus; Cruz-Jentoft, Alphonso; McCloskey, Eugene; Dawson-Hughes, Bess; Kaufman, Jean-Marc; Laslop, Andrea; Petermans, Jean; Reginster, Jean-Yves; Rizzoli, René; Robinson, Sian; Rolland, Yves; Rueda, Ricardo; Vellas, Bruno; Kanis, John A

    2018-04-01

    All proposed definitions of sarcopenia include the measurement of muscle mass, but the techniques and threshold values used vary. Indeed, the literature does not establish consensus on the best technique for measuring lean body mass. Thus, the objective measurement of sarcopenia is hampered by limitations intrinsic to assessment tools. The aim of this study was to review the methods to assess muscle mass and to reach consensus on the development of a reference standard. Literature reviews were performed by members of the European Society for Clinical and Economic Aspects of Osteoporosis and Osteoarthritis working group on frailty and sarcopenia. Face-to-face meetings were organized for the whole group to make amendments and discuss further recommendations. A wide range of techniques can be used to assess muscle mass. Cost, availability, and ease of use can determine whether the techniques are better suited to clinical practice or are more useful for research. No one technique subserves all requirements but dual energy X-ray absorptiometry could be considered as a reference standard (but not a gold standard) for measuring muscle lean body mass. Based on the feasibility, accuracy, safety, and low cost, dual energy X-ray absorptiometry can be considered as the reference standard for measuring muscle mass. © 2018 The Authors. Journal of Cachexia, Sarcopenia and Muscle published by John Wiley & Sons Ltd on behalf of the Society on Sarcopenia, Cachexia and Wasting Disorders.

  16. A flexible wearable sensor for knee flexion assessment during gait.

    PubMed

    Papi, Enrica; Bo, Yen Nee; McGregor, Alison H

    2018-05-01

    Gait analysis plays an important role in the diagnosis and management of patients with movement disorders but it is usually performed within a laboratory. Recently interest has shifted towards the possibility of conducting gait assessments in everyday environments thus facilitating long-term monitoring. This is possible by using wearable technologies rather than laboratory based equipment. This study aims to validate a novel wearable sensor system's ability to measure peak knee sagittal angles during gait. The proposed system comprises a flexible conductive polymer unit interfaced with a wireless acquisition node attached over the knee on a pair of leggings. Sixteen healthy volunteers participated to two gait assessments on separate occasions. Data was simultaneously collected from the novel sensor and a gold standard 10 camera motion capture system. The relationship between sensor signal and reference knee flexion angles was defined for each subject to allow the transformation of sensor voltage outputs to angular measures (degrees). The knee peak flexion angle from the sensor and reference system were compared by means of root mean square error (RMSE), absolute error, Bland-Altman plots and intra-class correlation coefficients (ICCs) to assess test-retest reliability. Comparisons of knee peak flexion angles calculated from the sensor and gold standard yielded an absolute error of 0.35(±2.9°) and RMSE of 1.2(±0.4)°. Good agreement was found between the two systems with the majority of data lying within the limits of agreement. The sensor demonstrated high test-retest reliability (ICCs>0.8). These results show the ability of the sensor to monitor knee peak sagittal angles with small margins of error and in agreement with the gold standard system. The sensor has potential to be used in clinical settings as a discreet, unobtrusive wearable device allowing for long-term gait analysis. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  17. Dispersive solid phase microextraction with magnetic graphene oxide as the sorbent for separation and preconcentration of ultra-trace amounts of gold ions.

    PubMed

    Kazemi, Elahe; Dadfarnia, Shayessteh; Haji Shabani, Ali Mohammad

    2015-08-15

    A selective, simple and rapid dispersive solid phase microextraction was developed using magnetic graphene oxide (MGO) as an efficient sorbent for the separation and preconcentration of gold ions. The MGO was synthesized by means of the simple one step chemical coprecipitation method, characterized by X-ray diffraction (XRD), Fourier transform infrared (FT-IR) spectroscopy and scanning electron microscopy (SEM). Gold ions retained by the sorbent were eluted using 0.5mol L(-)(1) thiourea in 0.1mol L(-1) HCl solution and determined by the flow injection flame atomic absorption spectrometry (FI-FAAS). The factors affecting the separation and preconcentration of gold were investigated and optimized. Under the optimized conditions, the method exhibited a linear dynamic range of 0.02-100.0µg L(-)(1) with a detection limit of 4ng L(-1) and an enrichment factor of 500. The relative standard deviations of 3.2% and 4.7% (n=6) were obtained at 20µg L(-1) level of gold ions for the intra and the inter day analysis, respectively. The method was successfully applied to the determination of gold ions in water and waste water samples as well as a certified reference material (CCU-1b, copper flotation concentrate). Copyright © 2015 Elsevier B.V. All rights reserved.

  18. A general approach for sample size calculation for the three-arm 'gold standard' non-inferiority design.

    PubMed

    Stucke, Kathrin; Kieser, Meinhard

    2012-12-10

    In the three-arm 'gold standard' non-inferiority design, an experimental treatment, an active reference, and a placebo are compared. This design is becoming increasingly popular, and it is, whenever feasible, recommended for use by regulatory guidelines. We provide a general method to calculate the required sample size for clinical trials performed in this design. As special cases, the situations of continuous, binary, and Poisson distributed outcomes are explored. Taking into account the correlation structure of the involved test statistics, the proposed approach leads to considerable savings in sample size as compared with application of ad hoc methods for all three scale levels. Furthermore, optimal sample size allocation ratios are determined that result in markedly smaller total sample sizes as compared with equal assignment. As optimal allocation makes the active treatment groups larger than the placebo group, implementation of the proposed approach is also desirable from an ethical viewpoint. Copyright © 2012 John Wiley & Sons, Ltd.

  19. Compliance with the guide for commissioning oral surgery: an audit and discussion.

    PubMed

    Modgill, O; Shah, A

    2017-10-13

    Introduction The Guide for commissioning oral surgery and oral medicine published by NHS England (2015) prescribes the level of complexity of oral surgery and oral medicine investigations and procedures to be carried out within NHS services. These are categorised as Level 1, Level 2, Level 3A and Level 3B. An audit was designed to ascertain the level of oral surgery procedures performed by clinicians of varying experience and qualification working in a large oral surgery department within a major teaching hospital.Materials and methods Two audit cycles were conducted on retrospective case notes and radiographic review of 100 patient records undergoing dental extractions within the Department of Oral Surgery at King's College Dental Hospital. The set gold standard was: '100% of Level 1 procedures should be performed by dental undergraduates or discharged back to the referring general dental practitioner'. Data were collected and analysed on a Microsoft Excel spreadsheet. The results of the first audit cycle were presented to all clinicians within the department in a formal meeting, recommendations were made and an action plan implemented prior to undertaking a second cycle.Results The first cycle revealed that 25% of Level 1 procedures met the set gold standard, with Level 2 practitioners performing the majority of Level 1 and Level 2 procedures. The second cycle showed a marked improvement, with 66% of Level 1 procedures meeting the set gold standard.Conclusion Our audit demonstrates that whilst we were able to achieve an improvement with the set gold standard, several barriers still remain to ensure that patients are treated by the appropriate level of clinician in a secondary care setting. We have used this audit as a foundation upon which to discuss the challenges faced in implementation of the commissioning framework within both primary and secondary dental care and strategies to overcome these challenges, which are likely to be encountered in any NHS care setting in which oral surgery procedures are performed.

  20. Fully automated MR liver volumetry using watershed segmentation coupled with active contouring.

    PubMed

    Huynh, Hieu Trung; Le-Trong, Ngoc; Bao, Pham The; Oto, Aytek; Suzuki, Kenji

    2017-02-01

    Our purpose is to develop a fully automated scheme for liver volume measurement in abdominal MR images, without requiring any user input or interaction. The proposed scheme is fully automatic for liver volumetry from 3D abdominal MR images, and it consists of three main stages: preprocessing, rough liver shape generation, and liver extraction. The preprocessing stage reduced noise and enhanced the liver boundaries in 3D abdominal MR images. The rough liver shape was revealed fully automatically by using the watershed segmentation, thresholding transform, morphological operations, and statistical properties of the liver. An active contour model was applied to refine the rough liver shape to precisely obtain the liver boundaries. The liver volumes calculated by the proposed scheme were compared to the "gold standard" references which were estimated by an expert abdominal radiologist. The liver volumes computed by using our developed scheme excellently agreed (Intra-class correlation coefficient was 0.94) with the "gold standard" manual volumes by the radiologist in the evaluation with 27 cases from multiple medical centers. The running time was 8.4 min per case on average. We developed a fully automated liver volumetry scheme in MR, which does not require any interaction by users. It was evaluated with cases from multiple medical centers. The liver volumetry performance of our developed system was comparable to that of the gold standard manual volumetry, and it saved radiologists' time for manual liver volumetry of 24.7 min per case.

  1. Sleep disordered breathing analysis in a general population using standard pulse oximeter signals.

    PubMed

    Barak-Shinar, Deganit; Amos, Yariv; Bogan, Richard K

    2013-09-01

    Obstructive sleep apnea reported as the apnea-hypopnea index (AHI) is usually measured in sleep laboratories using a high number of electrodes connected to the patient's body. In this study, we examined the use of a standard pulse oximeter system with an automated analysis based on the photoplethysmograph (PPG) signal for the diagnosis of sleep disordered breathing. Using a standard and simple device with high accuracy might provide a convenient diagnostic or screening solution for patient evaluation at home or in other out of center testing environments. The study included 140 consecutive patients that were referred routinely to a sleep laboratory [SleepMed Inc.] for the diagnosis of sleep disordered breathing. Each patient underwent an overnight polysomnography (PSG) study according to AASM guidelines in an AASM-accredited sleep laboratory. The automatic analysis is based on photoplethysmographic and saturation signals only. Those two signals were recorded for the entire night as part of the full overnight PSG sleep study. The AHI calculated from the PPG analysis is compared to the AHI calculated from the manual scoring gold standard full PSG. The AHI and total respiratory events measured by the pulse oximeter analysis correlated very well with the corresponding results obtained by the gold standard full PSG. The sensitivity and specificity of AHI = or > 5 and 15 levels measured by the analysis are both above 90 %. The sensitivity and positive predictive value for the detection of respiratory event are both above 84 %. The tested system in this study yielded an acceptable result of sleep disordered breathing compared to the gold standard PSG in patients with moderate to severe sleep apnea. Accordingly and given the convenience and simplicity of the standard pulse oximeter device, the new system can be considered suitable for home and ambulatory diagnosis or screening of sleep disordered breathing patients.

  2. Research Diagnostic Criteria for Temporomandibular Disorders: Validity of Axis I Diagnoses

    PubMed Central

    Truelove, Edmond; Pan, Wei; Look, John O.; Mancl, Lloyd A.; Ohrbach, Richard K.; Velly, Ana; Huggins, Kimberly; Lenton, Patricia; Schiffman, Eric L.

    2011-01-01

    AIMS To estimate the criterion validity of the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) Axis I TMD diagnoses. METHODS A combined total of 614 TMD community and clinic cases and 91 controls were examined at 3 study sites. RDC/TMD Axis I diagnoses were algorithmically derived from an examination performed by calibrated dental hygienists. Reference standards (Gold Standards) were established by means of consensus diagnoses rendered by 2 TMD experts using all available clinical data, including imaging studies. Validity of the RDC/TMD Axis I TMD diagnoses was estimated relative to reference-standard diagnoses (gold standard diagnoses). Target sensitivity and specificity were set a priori at ≥ 0.70 and ≥ 0.95, respectively. RESULTS Target sensitivity and specificity were not observed for any of the 8 RDC/TMD diagnoses. The highest validity was achieved for Group Ia myofascial pain (sensitivity 0.65, specificity 0.92) and Group Ib myofascial pain with limited opening (sensitivity 0.79, specificity 0.92). Target sensitivity and specificity were observed only when both Group I diagnoses were combined (0.87 and 0.98, respectively). For Group II (disc displacements) and Group III (arthralgia, arthritis, arthrosis) diagnoses, all estimates for sensitivity were below target (0.03 to 0.53), and specificity ranged from below to on target (0.86 to 0.99). CONCLUSION The RDC/TMD Axis I TMD diagnoses did not reach the targets set at sensitivity of ≥ 0.70 and specificity of ≥ 0.95. Target validity was obtained only for myofascial pain without differentiation between normal and limited opening. Revision of the current Axis I TMD diagnostic algorithms is warranted to improve their validity. PMID:20213030

  3. Advocacy: Making the Gold Standard School a Reality

    ERIC Educational Resources Information Center

    Roberts, Julia Link; Inman, Tracy Ford

    2011-01-01

    In their last column, the authors described a Gold Standard School--a place in which all children thrive including the gifted and talented. The Checklist for a Gold Standard School, which is included in this article, highlights the main characteristics of such a school including a focus on continuous progress, talent development, policies that…

  4. When the value of gold is zero.

    PubMed

    Chase, J Geoffrey; Moeller, Knut; Shaw, Geoffrey M; Schranz, Christoph; Chiew, Yeong Shiong; Desaive, Thomas

    2014-06-27

    This manuscript presents the concerns around the increasingly common problem of not having readily available or useful "gold standard" measurements. This issue is particularly important in critical care where many measurements used in decision making are surrogates of what we would truly wish to use. However, the question is broad, important and applicable in many other areas.In particular, a gold standard measurement often exists, but is not clinically (or ethically in some cases) feasible. The question is how does one even begin to develop new measurements or surrogates if one has no gold standard to compare with?We raise this issue concisely with a specific example from mechanical ventilation, a core bread and butter therapy in critical care that is also a leading cause of length of stay and cost of care. Our proposed solution centers around a hierarchical validation approach that we believe would ameliorate ethics issues around radiation exposure that make current gold standard measures clinically infeasible, and thus provide a pathway to create a (new) gold standard.

  5. Simulation studies of the fidelity of biomolecular structure ensemble recreation

    NASA Astrophysics Data System (ADS)

    Lätzer, Joachim; Eastwood, Michael P.; Wolynes, Peter G.

    2006-12-01

    We examine the ability of Bayesian methods to recreate structural ensembles for partially folded molecules from averaged data. Specifically we test the ability of various algorithms to recreate different transition state ensembles for folding proteins using a multiple replica simulation algorithm using input from "gold standard" reference ensembles that were first generated with a Gō-like Hamiltonian having nonpairwise additive terms. A set of low resolution data, which function as the "experimental" ϕ values, were first constructed from this reference ensemble. The resulting ϕ values were then treated as one would treat laboratory experimental data and were used as input in the replica reconstruction algorithm. The resulting ensembles of structures obtained by the replica algorithm were compared to the gold standard reference ensemble, from which those "data" were, in fact, obtained. It is found that for a unimodal transition state ensemble with a low barrier, the multiple replica algorithm does recreate the reference ensemble fairly successfully when no experimental error is assumed. The Kolmogorov-Smirnov test as well as principal component analysis show that the overlap of the recovered and reference ensembles is significantly enhanced when multiple replicas are used. Reduction of the multiple replica ensembles by clustering successfully yields subensembles with close similarity to the reference ensembles. On the other hand, for a high barrier transition state with two distinct transition state ensembles, the single replica algorithm only samples a few structures of one of the reference ensemble basins. This is due to the fact that the ϕ values are intrinsically ensemble averaged quantities. The replica algorithm with multiple copies does sample both reference ensemble basins. In contrast to the single replica case, the multiple replicas are constrained to reproduce the average ϕ values, but allow fluctuations in ϕ for each individual copy. These fluctuations facilitate a more faithful sampling of the reference ensemble basins. Finally, we test how robustly the reconstruction algorithm can function by introducing errors in ϕ comparable in magnitude to those suggested by some authors. In this circumstance we observe that the chances of ensemble recovery with the replica algorithm are poor using a single replica, but are improved when multiple copies are used. A multimodal transition state ensemble, however, turns out to be more sensitive to large errors in ϕ (if appropriately gauged) and attempts at successful recreation of the reference ensemble with simple replica algorithms can fall short.

  6. Conctact dermatitis: some important topics.

    PubMed

    Pigatto, P D

    2015-11-01

    Allergic contact dermatitis (ACD) is a type IV delayed hypersensitivity reaction. The gold standard for diagnosis is patch testing. The prevalence of positive patch tests in referred patients with suspected ACD ranges from 27 to 95.6%. The relationship between ACD and atopic dermatitis (AD) is complicated with conflicting reports of prevalence in the literature; however, in a patient with dermatitis not responding to traditional therapies, or with new areas of involvement, ACD should be considered as part of the work-up.

  7. The medline UK filter: development and validation of a geographic search filter to retrieve research about the UK from OVID medline.

    PubMed

    Ayiku, Lynda; Levay, Paul; Hudson, Tom; Craven, Jenny; Barrett, Elizabeth; Finnegan, Amy; Adams, Rachel

    2017-07-13

    A validated geographic search filter for the retrieval of research about the United Kingdom (UK) from bibliographic databases had not previously been published. To develop and validate a geographic search filter to retrieve research about the UK from OVID medline with high recall and precision. Three gold standard sets of references were generated using the relative recall method. The sets contained references to studies about the UK which had informed National Institute for Health and Care Excellence (NICE) guidance. The first and second sets were used to develop and refine the medline UK filter. The third set was used to validate the filter. Recall, precision and number-needed-to-read (NNR) were calculated using a case study. The validated medline UK filter demonstrated 87.6% relative recall against the third gold standard set. In the case study, the medline UK filter demonstrated 100% recall, 11.4% precision and a NNR of nine. A validated geographic search filter to retrieve research about the UK with high recall and precision has been developed. The medline UK filter can be applied to systematic literature searches in OVID medline for topics with a UK focus. © 2017 Crown copyright. Health Information and Libraries Journal © 2017 Health Libraries GroupThis article is published with the permission of the Controller of HMSO and the Queen's Printer for Scotland.

  8. The ToxBank Data Warehouse: Supporting the Replacement of In Vivo Repeated Dose Systemic Toxicity Testing.

    PubMed

    Kohonen, Pekka; Benfenati, Emilio; Bower, David; Ceder, Rebecca; Crump, Michael; Cross, Kevin; Grafström, Roland C; Healy, Lyn; Helma, Christoph; Jeliazkova, Nina; Jeliazkov, Vedrin; Maggioni, Silvia; Miller, Scott; Myatt, Glenn; Rautenberg, Michael; Stacey, Glyn; Willighagen, Egon; Wiseman, Jeff; Hardy, Barry

    2013-01-01

    The aim of the SEURAT-1 (Safety Evaluation Ultimately Replacing Animal Testing-1) research cluster, comprised of seven EU FP7 Health projects co-financed by Cosmetics Europe, is to generate a proof-of-concept to show how the latest technologies, systems toxicology and toxicogenomics can be combined to deliver a test replacement for repeated dose systemic toxicity testing on animals. The SEURAT-1 strategy is to adopt a mode-of-action framework to describe repeated dose toxicity, combining in vitro and in silico methods to derive predictions of in vivo toxicity responses. ToxBank is the cross-cluster infrastructure project whose activities include the development of a data warehouse to provide a web-accessible shared repository of research data and protocols, a physical compounds repository, reference or "gold compounds" for use across the cluster (available via wiki.toxbank.net), and a reference resource for biomaterials. Core technologies used in the data warehouse include the ISA-Tab universal data exchange format, REpresentational State Transfer (REST) web services, the W3C Resource Description Framework (RDF) and the OpenTox standards. We describe the design of the data warehouse based on cluster requirements, the implementation based on open standards, and finally the underlying concepts and initial results of a data analysis utilizing public data related to the gold compounds. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Rocking at 81 and Rolling at 34: ROC Cut-Off Scores for the Negative Acts Questionnaire–Revised in Serbia

    PubMed Central

    Petrović, Ivana B.; Vukelić, Milica; Čizmić, Svetlana

    2017-01-01

    Researchers are still searching for the ways to identify different categories of employees according to their exposure to negative acts and psychological experience of workplace bullying. We followed Notelaers and Einarsen’s application of the ROC analysis to determine the NAQ-R cut-off scores applying a “lower” and “higher” threshold. The main goal of this research was to develop and test different gold standards of personal and organizational relevance in determining the NAQ-R cut-off scores in a specific cultural and economic context of Serbia. Apart from combining self-labeling as a victim with self-perceived health, the objectives were to test the gold standards developed as a combination of self-labeling with life satisfaction, self-labeling with intention to leave and a complex gold standard based on self-labeling, self-perceived health, life satisfaction and intention to leave taken together. The ROC analysis on Serbian workforce data supports applying of different gold standards. For identifying employees in a preliminary stage of bullying, the most applicable was the gold standard based on self-labeling and intention to leave (score 34 and higher). The most accurate identification of victims could be based on the most complex gold standard (score 81 and higher). This research encourages further investigation of gold standards in different cultures. PMID:28119652

  10. Comparison of EHR-based diagnosis documentation locations to a gold standard for risk stratification in patients with multiple chronic conditions.

    PubMed

    Martin, Shelby; Wagner, Jesse; Lupulescu-Mann, Nicoleta; Ramsey, Katrina; Cohen, Aaron; Graven, Peter; Weiskopf, Nicole G; Dorr, David A

    2017-08-02

    To measure variation among four different Electronic Health Record (EHR) system documentation locations versus 'gold standard' manual chart review for risk stratification in patients with multiple chronic illnesses. Adults seen in primary care with EHR evidence of at least one of 13 conditions were included. EHRs were manually reviewed to determine presence of active diagnoses, and risk scores were calculated using three different methodologies and five EHR documentation locations. Claims data were used to assess cost and utilization for the following year. Descriptive and diagnostic statistics were calculated for each EHR location. Criterion validity testing compared the gold standard verified diagnoses versus other EHR locations and risk scores in predicting future cost and utilization. Nine hundred patients had 2,179 probable diagnoses. About 70% of the diagnoses from the EHR were verified by gold standard. For a subset of patients having baseline and prediction year data (n=750), modeling showed that the gold standard was the best predictor of outcomes on average for a subset of patients that had these data. However, combining all data sources together had nearly equivalent performance for prediction as the gold standard. EHR data locations were inaccurate 30% of the time, leading to improvement in overall modeling from a gold standard from chart review for individual diagnoses. However, the impact on identification of the highest risk patients was minor, and combining data from different EHR locations was equivalent to gold standard performance. The reviewer's ability to identify a diagnosis as correct was influenced by a variety of factors, including completeness, temporality, and perceived accuracy of chart data.

  11. The construction of standard gamble utilities.

    PubMed

    van Osch, Sylvie M C; Stiggelbout, Anne M

    2008-01-01

    Health effects for cost-effectiveness analysis are best measured in life years, with quality of life in each life year expressed in terms of utilities. The standard gamble (SG) has been the gold standard for utility measurement. However, the biases of probability weighting, loss aversion, and scale compatibility have an inconclusive effect on SG utilities. We determined their effect on SG utilities using qualitative data to assess the reference point and the focus of attention. While thinking aloud, 45 healthy respondents provided SG utilities for six rheumatoid arthritis health states. Reference points, goals, and focuses of attention were coded. To assess the effect of scale compatibility, correlations were assessed between focus of attention and mean utility. The certain outcome served most frequently as reference point, the SG was perceived as a mixed gamble. Goals were mostly mentioned with respect to this outcome. Scale compatibility led to a significant upward bias in utilities; attention lay relatively more on the low outcome and this was positively correlated with mean utility. SG utilities should be corrected for loss aversion and probability weighting with the mixed correction formula proposed by prospect theory. Scale compatibility will likely still bias SG utilities, calling for research on a correction. Copyright (c) 2007 John Wiley & Sons, Ltd.

  12. A Simple and Selective Spectrophotometric Method for the Determination of Trace Gold in Real, Environmental, Biological, Geological and Soil Samples Using Bis (Salicylaldehyde) Orthophenylenediamine

    PubMed Central

    Soomro, Rubina; Ahmed, M. Jamaluddin; Memon, Najma; Khan, Humaira

    2008-01-01

    A simple high sensitive, selective, and rapid spectrophotometric method for the determination of trace gold based on the rapid reaction of gold(III) with bis(salicylaldehyde)orthophenylenediamine (BSOPD) in aqueous and micellar media has been developed. BSOPD reacts with gold(III) in slightly acidic solution to form a 1:1 brownish-yellow complex, which has an maximum absorption peak at 490 nm in both aqueous and micellar media. The most remarkable point of this method is that the molar absorptivities of the gold-BSOPD complex form in the presence of the nonionic TritonX-100 surfactant are almost a 10 times higher than the value observed in the aqueous solution, resulting in an increase in the sensitivity and selectivity of the method. The apparent molar absorptivities were found to be 2.3 × 104 L mol−1 cm−1 and 2.5 × 105 L mol−1 cm−1 in aqueous and micellar media, respectively. The reaction is instantaneous and the maximum absorbance was obtained after 10 min at 490 nm and remains constant for over 24 h at room temperature. The linear calibration graphs were obtained for 0.1–30 mg L−1 and 0.01–30 mg L−1 of gold(III) in aqueous and surfactant media, respectively. The interference from over 50 cations, anions and complexing agents has been studied at 1 mg L−1 of Au(III); most metal ions can be tolerated in considerable amounts in aqueous micellar solutions. The Sandell’s sensitivity, the limit of detection and relative standard deviation (n = 9) were found to be 5 ng cm−2, 1 ng mL−1 and 2%, respectively in aqueous micellar solutions. Its sensitivity and selectivity are remarkably higher than that of other reagents in the literature. The proposed method was successfully used in the determination of gold in several standard reference materials (alloys and steels), environmental water samples (potable and polluted), and biological samples (blood and urine), geological, soil and complex synthetic mixtures. The results obtained agree well with those samples analyzed by atomic absorption spectrophotometry (AAS). PMID:19609392

  13. Validation of assessment of intraoral digital photography for evaluation of dental restorations in clinical research.

    PubMed

    Signori, Cácia; Collares, Kauê; Cumerlato, Catarina B F; Correa, Marcos B; Opdam, Niek J M; Cenci, Maximiliano S

    2018-04-01

    The aim of this study was to investigate the validity of assessment of intraoral digital photography in the evaluation of dental restorations. Intraoral photographs of anterior and posterior restorations were classified based on FDI criteria according to the need for intervention: no intervention, repair and replacement. Evaluations were performed by an experienced expert in restorative dentistry (gold standard evaluator) and 3 trained dentists (consensus). The clinical inspection was the reference standard method. The prevalence of failures was explored. Cohen's kappa statistic was used. Validity was accessed by sensitivity, specificity, likelihood ratio and predictives values. Higher prevalence of failed restorations intervention was identified by the intraoral photography (17.7%) in comparison to the clinical evaluation (14.1%). Moderate agreement in the diagnosis of total failures was shown between the methods for the gold standard evaluator (kappa = 0.51) and consensus of evaluators (kappa = 0.53). Gold standard evaluator and consensus showed substantial and moderate agreement for posterior restorations (kappa = 0.61; 0.59), and fair and moderate agreement for anterior restorations (kappa = 0.36; 0.43), respectively. The accuracy was 84.8% in the assessment by intraoral photographs. Sensitivity and specificity values of 87.5% and 89.3% were found. Under the limits of this study, the assessment of digital photography performed by intraoral camera is an indirect diagnostic method valid for the evaluation of dental restorations, mainly in posterior teeth. This method should be employed taking into account the higher detection of defects provided by the images, which are not always clinically relevant. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. Evaluation of an On-Farm Culture System (Accumast) for Fast Identification of Milk Pathogens Associated with Clinical Mastitis in Dairy Cows.

    PubMed

    Ganda, Erika Korzune; Bisinotto, Rafael Sisconeto; Decter, Dean Harrison; Bicalho, Rodrigo Carvalho

    2016-01-01

    The present study aimed evaluate an on-farm culture system for identification of milk pathogens associated with clinical mastitis in dairy cows using two different gold standard approaches: standard laboratory culture in study 1 and 16S rRNA sequencing in study 2. In study 1, milk from mastitic quarters (i.e. presence of flakes, clots, or serous milk; n = 538) was cultured on-farm using a single plate containing three selective chromogenic media (Accumast-FERA Animal Health LCC, Ithaca, NY) and in a reference laboratory using standard culture methods, which was considered the gold standard. In study 2, mastitic milk was cultured on-farm and analyzed through 16S rRNA sequencing (n = 214). In both studies, plates were cultured aerobically at 37°C for 24 h and read by a single technician masked to gold standard results. Accuracy, sensitivity, specificity, positive (PPV) and negative predictive value (NPV) were calculated based on standard laboratory culture in study 1, and PPV was calculated based on sequencing results in study 2. Overall accuracy of Accumast was 84.9%. Likewise, accuracy for identification of Gram-negative bacteria, Staphylococcus sp., and Streptococcus sp. was 96.4%, 93.8%, and 91.5%, respectively. Sensitivity, specificity, PPV, and NPV were 75.0%, 97.9%, 79.6%, and 97.3% for identification of E. coli, 100.0%, 99.8%, 87.5%, and 100.0% for S. aureus, 70.0%, 95.0%, 45.7%, and 98.1% for other Staphylococcus sp., and 90.0%, 92.9%, 91.8%, and 91.2% for Streptococcus sp. In study 2, Accumast PPV was 96.7% for E. coli, 100.0% for Enterococcus sp., 100.0% for Other Gram-negatives, 88.2% for Staphylococcus sp., and 95.0% for Streptococcus sp., respectively. In conclusion, Accumast is a unique approach for on-farm identification pathogens associated with mastitis, presenting overall sensitivity and specificity of 82.3% and 89.9% respectively.

  15. Evaluation of an On-Farm Culture System (Accumast) for Fast Identification of Milk Pathogens Associated with Clinical Mastitis in Dairy Cows

    PubMed Central

    Ganda, Erika Korzune; Bisinotto, Rafael Sisconeto; Decter, Dean Harrison; Bicalho, Rodrigo Carvalho

    2016-01-01

    The present study aimed evaluate an on-farm culture system for identification of milk pathogens associated with clinical mastitis in dairy cows using two different gold standard approaches: standard laboratory culture in study 1 and 16S rRNA sequencing in study 2. In study 1, milk from mastitic quarters (i.e. presence of flakes, clots, or serous milk; n = 538) was cultured on-farm using a single plate containing three selective chromogenic media (Accumast—FERA Animal Health LCC, Ithaca, NY) and in a reference laboratory using standard culture methods, which was considered the gold standard. In study 2, mastitic milk was cultured on-farm and analyzed through 16S rRNA sequencing (n = 214). In both studies, plates were cultured aerobically at 37°C for 24 h and read by a single technician masked to gold standard results. Accuracy, sensitivity, specificity, positive (PPV) and negative predictive value (NPV) were calculated based on standard laboratory culture in study 1, and PPV was calculated based on sequencing results in study 2. Overall accuracy of Accumast was 84.9%. Likewise, accuracy for identification of Gram-negative bacteria, Staphylococcus sp., and Streptococcus sp. was 96.4%, 93.8%, and 91.5%, respectively. Sensitivity, specificity, PPV, and NPV were 75.0%, 97.9%, 79.6%, and 97.3% for identification of E. coli, 100.0%, 99.8%, 87.5%, and 100.0% for S. aureus, 70.0%, 95.0%, 45.7%, and 98.1% for other Staphylococcus sp., and 90.0%, 92.9%, 91.8%, and 91.2% for Streptococcus sp. In study 2, Accumast PPV was 96.7% for E. coli, 100.0% for Enterococcus sp., 100.0% for Other Gram-negatives, 88.2% for Staphylococcus sp., and 95.0% for Streptococcus sp., respectively. In conclusion, Accumast is a unique approach for on-farm identification pathogens associated with mastitis, presenting overall sensitivity and specificity of 82.3% and 89.9% respectively. PMID:27176216

  16. Copper Oxide Precipitates in NBS Standard Reference Material 482

    PubMed Central

    Windsor, Eric S.; Carlton, Robert A.; Gillen, Greg; Wight, Scott A.; Bright, David S.

    2002-01-01

    Copper oxide has been detected in the copper containing alloys of NBS Standard Reference Material (SRM) 482. This occurrence is significant because it represents heterogeneity within a standard reference material that was certified to be homogeneous on a micrometer scale. Oxide occurs as elliptically to spherically shaped precipitates whose size differs with alloy composition. The largest precipitates occur in the Au20-Cu80 alloy and range in size from submicrometer up to 2 μm in diameter. Precipitates are observed using light microscopy, electron microscopy, and secondary ion mass spectrometry (SIMS). SIMS has demonstrated that the precipitates are present within all the SRM 482 wires that contain copper. Only the pure gold wire is precipitate free. Initial results from the analysis of the Au20-Cu80 alloy indicate that the percentage of precipitates is less than 1 % by area. Electron probe microanalysis (EPMA) of large (2 μm) precipitates in this same alloy indicates that precipitates are detectable by EPMA and that their composition differs significantly from the certified alloy composition. The small size and low percentage of these oxide precipitates minimizes the impact that they have upon the intended use of this standard for electron probe microanalysis. Heterogeneity caused by these oxide precipitates may however preclude the use of this standard for automated EPMA analyses and other microanalysis techniques. PMID:27446759

  17. Evaluation of the OnSite (Pf/Pan) rapid diagnostic test for diagnosis of clinical malaria

    PubMed Central

    2012-01-01

    Background Accurate diagnosis of malaria is an essential prerequisite for proper treatment and drug resistance monitoring. Microscopy is considered the gold standard for malaria diagnosis but has limitations. ELISA, PCR, and Real Time PCR are also used to diagnose malaria in reference laboratories, although their application at the field level is currently not feasible. Rapid diagnostic tests (RDTs) however, have been brought into field operation and widely adopted in recent days. This study evaluates OnSite (Pf/Pan) antigen test, a new RDT introduced by CTK Biotech Inc, USA for malaria diagnosis in a reference setting. Methods Blood samples were collected from febrile patients referred for malaria diagnosis by clinicians. Subjects were included in this study from two different Upazila Health Complexes (UHCs) situated in two malaria endemic districts of Bangladesh. Microscopy and nested PCR were considered the gold standard in this study. OnSite (Pf/Pan) RDT was performed on preserved whole blood samples. Results In total, 372 febrile subjects were included in this study. Of these subjects, 229 (61.6%) tested positive for Plasmodium infection detected by microscopy and nested PCR. OnSite (Pf/Pan) RDT was 94.2% sensitive (95% CI, 89.3-97.3) and 99.5% specific (95% CI, 97.4-00.0) for Plasmodium falciparum diagnosis and 97.3% sensitive (95% CI, 90.5-99.7) and 98.7% specific (95% CI, 96.6-99.6) for Plasmodium vivax diagnosis. Sensitivity varied with differential parasite count for both P. falciparum and P. vivax. The highest sensitivity was observed in febrile patients with parasitaemia that ranged from 501–1,000 parasites/μL regardless of the Plasmodium species. Conclusion The new OnSite (Pf/Pan) RDT is both sensitive and specific for symptomatic malaria diagnosis in standard laboratory conditions. PMID:23234579

  18. Gold-standard for computer-assisted morphological sperm analysis.

    PubMed

    Chang, Violeta; Garcia, Alejandra; Hitschfeld, Nancy; Härtel, Steffen

    2017-04-01

    Published algorithms for classification of human sperm heads are based on relatively small image databases that are not open to the public, and thus no direct comparison is available for competing methods. We describe a gold-standard for morphological sperm analysis (SCIAN-MorphoSpermGS), a dataset of sperm head images with expert-classification labels in one of the following classes: normal, tapered, pyriform, small or amorphous. This gold-standard is for evaluating and comparing known techniques and future improvements to present approaches for classification of human sperm heads for semen analysis. Although this paper does not provide a computational tool for morphological sperm analysis, we present a set of experiments for comparing sperm head description and classification common techniques. This classification base-line is aimed to be used as a reference for future improvements to present approaches for human sperm head classification. The gold-standard provides a label for each sperm head, which is achieved by majority voting among experts. The classification base-line compares four supervised learning methods (1- Nearest Neighbor, naive Bayes, decision trees and Support Vector Machine (SVM)) and three shape-based descriptors (Hu moments, Zernike moments and Fourier descriptors), reporting the accuracy and the true positive rate for each experiment. We used Fleiss' Kappa Coefficient to evaluate the inter-expert agreement and Fisher's exact test for inter-expert variability and statistical significant differences between descriptors and learning techniques. Our results confirm the high degree of inter-expert variability in the morphological sperm analysis. Regarding the classification base line, we show that none of the standard descriptors or classification approaches is best suitable for tackling the problem of sperm head classification. We discovered that the correct classification rate was highly variable when trying to discriminate among non-normal sperm heads. By using the Fourier descriptor and SVM, we achieved the best mean correct classification: only 49%. We conclude that the SCIAN-MorphoSpermGS will provide a standard tool for evaluation of characterization and classification approaches for human sperm heads. Indeed, there is a clear need for a specific shape-based descriptor for human sperm heads and a specific classification approach to tackle the problem of high variability within subcategories of abnormal sperm cells. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Automatic detection of end-diastolic and end-systolic frames in 2D echocardiography.

    PubMed

    Zolgharni, Massoud; Negoita, Madalina; Dhutia, Niti M; Mielewczik, Michael; Manoharan, Karikaran; Sohaib, S M Afzal; Finegold, Judith A; Sacchi, Stefania; Cole, Graham D; Francis, Darrel P

    2017-07-01

    Correctly selecting the end-diastolic and end-systolic frames on a 2D echocardiogram is important and challenging, for both human experts and automated algorithms. Manual selection is time-consuming and subject to uncertainty, and may affect the results obtained, especially for advanced measurements such as myocardial strain. We developed and evaluated algorithms which can automatically extract global and regional cardiac velocity, and identify end-diastolic and end-systolic frames. We acquired apical four-chamber 2D echocardiographic video recordings, each at least 10 heartbeats long, acquired twice at frame rates of 52 and 79 frames/s from 19 patients, yielding 38 recordings. Five experienced echocardiographers independently marked end-systolic and end-diastolic frames for the first 10 heartbeats of each recording. The automated algorithm also did this. Using the average of time points identified by five human operators as the reference gold standard, the individual operators had a root mean square difference from that gold standard of 46.5 ms. The algorithm had a root mean square difference from the human gold standard of 40.5 ms (P<.0001). Put another way, the algorithm-identified time point was an outlier in 122/564 heartbeats (21.6%), whereas the average human operator was an outlier in 254/564 heartbeats (45%). An automated algorithm can identify the end-systolic and end-diastolic frames with performance indistinguishable from that of human experts. This saves staff time, which could therefore be invested in assessing more beats, and reduces uncertainty about the reliability of the choice of frame. © 2017, Wiley Periodicals, Inc.

  20. Is the Surface Potential Integral of a Dipole in a Volume Conductor Always Zero? A Cloud Over the Average Reference of EEG and ERP.

    PubMed

    Yao, Dezhong

    2017-03-01

    Currently, average reference is one of the most widely adopted references in EEG and ERP studies. The theoretical assumption is the surface potential integral of a volume conductor being zero, thus the average of scalp potential recordings might be an approximation of the theoretically desired zero reference. However, such a zero integral assumption has been proved only for a spherical surface. In this short communication, three counter-examples are given to show that the potential integral over the surface of a dipole in a volume conductor may not be zero. It depends on the shape of the conductor and the orientation of the dipole. This fact on one side means that average reference is not a theoretical 'gold standard' reference, and on the other side reminds us that the practical accuracy of average reference is not only determined by the well-known electrode array density and its coverage but also intrinsically by the head shape. It means that reference selection still is a fundamental problem to be fixed in various EEG and ERP studies.

  1. Statistical studies of selected trace elements with reference to geology and genesis of the Carlin gold deposit, Nevada

    USGS Publications Warehouse

    Harris, Michael; Radtke, Arthur S.

    1976-01-01

    Linear regression and discriminant analyses techniques were applied to gold, mercury, arsenic, antimony, barium, copper, molybdenum, lead, zinc, boron, tellurium, selenium, and tungsten analyses from drill holes into unoxidized gold ore at the Carlin gold mine near Carlin, Nev. The statistical treatments employed were used to judge proposed hypotheses on the origin and geochemical paragenesis of this disseminated gold deposit.

  2. Protocol for determining the diagnostic validity of physical examination maneuvers for shoulder pathology.

    PubMed

    Somerville, Lyndsay; Bryant, Dianne; Willits, Kevin; Johnson, Andrew

    2013-02-08

    Shoulder complaints are the third most common musculoskeletal problem in the general population. There are an abundance of physical examination maneuvers for diagnosing shoulder pathology. The validity of these maneuvers has not been adequately addressed. We propose a large Phase III study to investigate the accuracy of these tests in an orthopaedic setting. We will recruit consecutive new shoulder patients who are referred to two tertiary orthopaedic clinics. We will select which physical examination tests to include using a modified Delphi process. The physician will take a thorough history from the patient and indicate their certainty about each possible diagnosis (certain the diagnosis is absent, present or requires further testing). The clinician will only perform the physical examination maneuvers for diagnoses where uncertainty remains. We will consider arthroscopy the reference standard for patients who undergo surgery within 8 months of physical examination and magnetic resonance imaging with arthrogram for patients who do not. We will calculate the sensitivity, specificity and positive and negative likelihood ratios and investigate whether combinations of the top tests provide stronger predictions of the presence or absence of disease. There are several considerations when performing a diagnostic study to ensure that the results are applicable in a clinical setting. These include, 1) including a representative sample, 2) selecting an appropriate reference standard, 3) avoiding verification bias, 4) blinding the interpreters of the physical examination tests to the interpretation of the gold standard and, 5) blinding the interpreters of the gold standard to the interpretation of the physical examination tests. The results of this study will inform clinicians of which tests, or combination of tests, successfully reduce diagnostic uncertainty, which tests are misleading and how physical examination may affect the magnitude of the confidence the clinician feels about their diagnosis. The results of this study may reduce the number of costly and invasive imaging studies (MRI, CT or arthrography) that are requisitioned when uncertainty about diagnosis remains following history and physical exam. We also hope to reduce the variability between specialists in which maneuvers are used during physical examination and how they are used, all of which will assist in improving consistency of care between centres.

  3. Accuracy of body mass index for age to diagnose obesity in Mexican schoolchildren.

    PubMed

    Mendoza Pablo, Pedro A; Valdés, Jesús; Ortiz-Hernández, Luis

    2015-06-01

    To compare the accuracy of three BMI-forage references (World Health Organization reference, WHO; the updated International Obesity Task Force reference, IOTF; and Centers for Disease Control and Prevention (CDC) growth charts) to diagnose obesity in Mexican children. A convenience sample of Mexican schoolchildren (n = 218) was assessed. The gold standard was the percentage of body fat estimated by deuterium dilution technique. Sensitivity and specificity of the classical cutoff point of BMI-for-age to identify obesity (i.e. > 2.00 standard deviation, SD) were estimated. The accuracy (i.e. area under the curve, AUC) of three BMI-for-age references for the diagnosis of obesity was estimated with the receiver operating characteristic (ROC) curves method. The optimal cutoff point (OCP) was determined. The cutoff points to identify obesity had low (WHO reference: 57.6%, CDC: 53.5%) to very low (IOTF reference: 40.4%) sensitivities, but adequate specificities (91.6%, 95.0%, and, 97.5%, respectively). The AUC of the three references were adequate (0.89). For the IOTF reference, the AUC was lower among the older children. The OCP for the CDC reference (1.24 SD) was lower than the OCP for WHO (1.53 SD) and IOTF charts (1.47 SD). The classical cutoff point for obesity has low sensitivity--especially for the IOTF reference. The accuracy of the three references was similar. However, to obtain comparable diagnosis of obesity different cutoff points should be used depending of the reference. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  4. An ROC-type measure of diagnostic accuracy when the gold standard is continuous-scale.

    PubMed

    Obuchowski, Nancy A

    2006-02-15

    ROC curves and summary measures of accuracy derived from them, such as the area under the ROC curve, have become the standard for describing and comparing the accuracy of diagnostic tests. Methods for estimating ROC curves rely on the existence of a gold standard which dichotomizes patients into disease present or absent. There are, however, many examples of diagnostic tests whose gold standards are not binary-scale, but rather continuous-scale. Unnatural dichotomization of these gold standards leads to bias and inconsistency in estimates of diagnostic accuracy. In this paper, we propose a non-parametric estimator of diagnostic test accuracy which does not require dichotomization of the gold standard. This estimator has an interpretation analogous to the area under the ROC curve. We propose a confidence interval for test accuracy and a statistical test for comparing accuracies of tests from paired designs. We compare the performance (i.e. CI coverage, type I error rate, power) of the proposed methods with several alternatives. An example is presented where the accuracies of two quick blood tests for measuring serum iron concentrations are estimated and compared.

  5. Task-based evaluation of segmentation algorithms for diffusion-weighted MRI without using a gold standard

    PubMed Central

    Jha, Abhinav K.; Kupinski, Matthew A.; Rodríguez, Jeffrey J.; Stephen, Renu M.; Stopeck, Alison T.

    2012-01-01

    In many studies, the estimation of the apparent diffusion coefficient (ADC) of lesions in visceral organs in diffusion-weighted (DW) magnetic resonance images requires an accurate lesion-segmentation algorithm. To evaluate these lesion-segmentation algorithms, region-overlap measures are used currently. However, the end task from the DW images is accurate ADC estimation, and the region-overlap measures do not evaluate the segmentation algorithms on this task. Moreover, these measures rely on the existence of gold-standard segmentation of the lesion, which is typically unavailable. In this paper, we study the problem of task-based evaluation of segmentation algorithms in DW imaging in the absence of a gold standard. We first show that using manual segmentations instead of gold-standard segmentations for this task-based evaluation is unreliable. We then propose a method to compare the segmentation algorithms that does not require gold-standard or manual segmentation results. The no-gold-standard method estimates the bias and the variance of the error between the true ADC values and the ADC values estimated using the automated segmentation algorithm. The method can be used to rank the segmentation algorithms on the basis of both accuracy and precision. We also propose consistency checks for this evaluation technique. PMID:22713231

  6. Boosting drug named entity recognition using an aggregate classifier.

    PubMed

    Korkontzelos, Ioannis; Piliouras, Dimitrios; Dowsey, Andrew W; Ananiadou, Sophia

    2015-10-01

    Drug named entity recognition (NER) is a critical step for complex biomedical NLP tasks such as the extraction of pharmacogenomic, pharmacodynamic and pharmacokinetic parameters. Large quantities of high quality training data are almost always a prerequisite for employing supervised machine-learning techniques to achieve high classification performance. However, the human labour needed to produce and maintain such resources is a significant limitation. In this study, we improve the performance of drug NER without relying exclusively on manual annotations. We perform drug NER using either a small gold-standard corpus (120 abstracts) or no corpus at all. In our approach, we develop a voting system to combine a number of heterogeneous models, based on dictionary knowledge, gold-standard corpora and silver annotations, to enhance performance. To improve recall, we employed genetic programming to evolve 11 regular-expression patterns that capture common drug suffixes and used them as an extra means for recognition. Our approach uses a dictionary of drug names, i.e. DrugBank, a small manually annotated corpus, i.e. the pharmacokinetic corpus, and a part of the UKPMC database, as raw biomedical text. Gold-standard and silver annotated data are used to train maximum entropy and multinomial logistic regression classifiers. Aggregating drug NER methods, based on gold-standard annotations, dictionary knowledge and patterns, improved the performance on models trained on gold-standard annotations, only, achieving a maximum F-score of 95%. In addition, combining models trained on silver annotations, dictionary knowledge and patterns are shown to achieve comparable performance to models trained exclusively on gold-standard data. The main reason appears to be the morphological similarities shared among drug names. We conclude that gold-standard data are not a hard requirement for drug NER. Combining heterogeneous models build on dictionary knowledge can achieve similar or comparable classification performance with that of the best performing model trained on gold-standard annotations. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  7. Exposure and toxic effects of elemental mercury in gold-mining activities in Ecuador.

    PubMed

    Harari, Raúl; Harari, Florencia; Gerhardsson, Lars; Lundh, Thomas; Skerfving, Staffan; Strömberg, Ulf; Broberg, Karin

    2012-08-13

    Traditional gold mining, using metallic mercury (Hg(0)) to form gold amalgam, followed by burning to remove the Hg(0), is widely used in South America, Africa and Asia. The gold is sold to merchants who burn it again to eliminate remaining Hg(0). In Ecuador, 200 gold miners, 37 gold merchants and 72 referents were studied. The median Hg concentrations in urine (U-Hg) were 3.3 (range 0.23-170), 37 (3.2-420), and 1.6 (0.2-13)μg/g creatinine, respectively, and in whole blood (B-Hg) were 5.2, 30, and 5.0 μg/L, respectively. Biomarker concentrations among merchants were statistically significantly higher than among miners and referents; also the miners differed from the referents. Burning of gold amalgam among miners was intermittent; U-Hg decreased in the burning-free period. In computerized neuromotor examinations, B-Hg and U-Hg concentrations were associated with increases in the centre frequency of the tremor, as well as in reaction time and postural stability.Retention of Hg (B-Hg), and the elimination rate (U-Hg) appears to be modified by polymorphism in a gene of an enzyme in the glutathione synthesis (GCLM), but there were no significant genetic modifications for the associations between exposure and neurotoxicity.Thus, the gold merchants have a much higher exposure and risk than the miners, in whom the exposure varies over time. The metabolism of Hg is modified by genetic traits. The present exposure to Hg had limited neurotoxic effects. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  8. Automatic extraction of angiogenesis bioprocess from text

    PubMed Central

    Wang, Xinglong; McKendrick, Iain; Barrett, Ian; Dix, Ian; French, Tim; Tsujii, Jun'ichi; Ananiadou, Sophia

    2011-01-01

    Motivation: Understanding key biological processes (bioprocesses) and their relationships with constituent biological entities and pharmaceutical agents is crucial for drug design and discovery. One way to harvest such information is searching the literature. However, bioprocesses are difficult to capture because they may occur in text in a variety of textual expressions. Moreover, a bioprocess is often composed of a series of bioevents, where a bioevent denotes changes to one or a group of cells involved in the bioprocess. Such bioevents are often used to refer to bioprocesses in text, which current techniques, relying solely on specialized lexicons, struggle to find. Results: This article presents a range of methods for finding bioprocess terms and events. To facilitate the study, we built a gold standard corpus in which terms and events related to angiogenesis, a key biological process of the growth of new blood vessels, were annotated. Statistics of the annotated corpus revealed that over 36% of the text expressions that referred to angiogenesis appeared as events. The proposed methods respectively employed domain-specific vocabularies, a manually annotated corpus and unstructured domain-specific documents. Evaluation results showed that, while a supervised machine-learning model yielded the best precision, recall and F1 scores, the other methods achieved reasonable performance and less cost to develop. Availability: The angiogenesis vocabularies, gold standard corpus, annotation guidelines and software described in this article are available at http://text0.mib.man.ac.uk/~mbassxw2/angiogenesis/ Contact: xinglong.wang@gmail.com PMID:21821664

  9. Modified method of recording and reproducing natural head position with a multicamera system and a laser level.

    PubMed

    Liu, Xiao-jing; Li, Qian-qian; Pang, Yuan-jie; Tian, Kai-yue; Xie, Zheng; Li, Zi-li

    2015-06-01

    As computer-assisted surgical design becomes increasingly popular in maxillofacial surgery, recording patients' natural head position (NHP) and reproducing it in the virtual environment are vital for preoperative design and postoperative evaluation. Our objective was to test the repeatability and accuracy of recording NHP using a multicamera system and a laser level. A laser level was used to project a horizontal reference line on a physical model, and a 3-dimensional image was obtained using a multicamera system. In surgical simulation software, the recorded NHP was reproduced in the virtual head position by registering the coordinate axes with the horizontal reference on both the frontal and lateral views. The repeatability and accuracy of the method were assessed using a gyroscopic procedure as the gold standard. The interclass correlation coefficients for pitch and roll were 0.982 (0.966, 0.991) and 0.995 (0.992, 0.998), respectively, indicating a high degree of repeatability. Regarding accuracy, the lack of agreement in orientation between the new method and the gold standard was within the ranges for pitch (-0.69°, 1.71°) and for roll (-0.92°, 1.20°); these have no clinical significance. This method of recording and reproducing NHP with a multicamera system and a laser level is repeatable, accurate, and clinically feasible. Copyright © 2015 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  10. Gold occurrences in the Greenville 1 degree by 2 degrees Quadrangle, South Carolina, Georgia, and North Carolina

    USGS Publications Warehouse

    D'Agostino, John P.; Mason, George T.; Zupan, Alan J.W.; Maybin, Arthur H.; German, Jerry M.; Abrams, Charlotte E.

    1994-01-01

    All of the gold mines, prospects, placers, and occurrences known in the Greenville 1° x 2° quadrangle are tabulated in this report. The table lists, in consecutive order by county (fig. 1), the map number of each feature, which is located either on the accompanying Greenville 1° x 2° quadrangle map or figure 2. The known name of the feature; the 7.5' topographic map on the which the gold site is located (if known, within 25 ft or 7.6 m), the Universal Transverse Mercator (UTM) northing and easting grid coordinates from the appropriate 7.5' topographic map; the commodity; remarks; and references are also listed. Some locations are known, but many sites are not verified and their locations are only approximate. References are listed in References Cited and referred to by number to save space.

  11. Low cost ellipsometer using a standard commercial polarimeter

    NASA Astrophysics Data System (ADS)

    Velosa, F.; Abreu, M.

    2017-08-01

    Ellipsometry is an optical technique to characterize materials or phenomena that occurs at an interface or thin film between two different media. In this paper, we present an experimental low-cost version of a photometric ellipsometer, assembled with commonly found material at every Optics laboratory. The polarization parameters measurement was performed using a Thorlabs PAX5710 polarimeter. The uncertainty computed using the Guide to the Expression of Uncertainty in Measurement (GUM) procedures. With the assembled ellipsometer we were able to measure the thickness of a 10 nm thick SiO2 thin film deposited upon Si, and the complex refractive index of Gold and Tantalum samples. The SiO2 thickness we achieved had an experimental deviation of 4.5% with 2.00 nm uncertainty. The value complex refractive index of Gold and Tantalum measured agrees with the different values found in several references. The uncertainty values were found to be mostly limited by the polarimeter's uncertainty.

  12. Plasmonic Nanowires for Wide Wavelength Range Molecular Sensing.

    PubMed

    Marinaro, Giovanni; Das, Gobind; Giugni, Andrea; Allione, Marco; Torre, Bruno; Candeloro, Patrizio; Kosel, Jurgen; Di Fabrizio, Enzo

    2018-05-17

    In this paper, we propose the use of a standing nanowires array, constituted by plasmonic active gold wires grown on iron disks, and partially immersed in a supporting alumina matrix, for surface-enhanced Raman spectroscopy applications. The galvanic process was used to fabricate nanowires in pores of anodized alumina template, making this device cost-effective. This fabrication method allows for the selection of size, diameter, and spatial arrangement of nanowires. The proposed device, thanks to a detailed design analysis, demonstrates a broadband plasmonic enhancement effect useful for many standard excitation wavelengths in the visible and NIR. The trigonal pores arrangement gives an efficiency weakly dependent on polarization. The devices, tested with 633 and 830 nm laser lines, show a significant Raman enhancement factor, up to around 6 × 10⁴, with respect to the flat gold surface, used as a reference for the measurements of the investigated molecules.

  13. 75 FR 28227 - National Emission Standards for Hazardous Air Pollutants: Gold Mine Ore Processing and Production...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-20

    ... published a proposed rule for mercury emissions from the gold mine ore processing and production area source... proposed rule (75 FR 22470). Several parties requested that EPA extend the comment period. EPA has granted...-AP48 National Emission Standards for Hazardous Air Pollutants: Gold Mine Ore Processing and Production...

  14. Use of dual-energy X-ray absorptiometry (DXA) for diagnosis and fracture risk assessment; WHO-criteria, T- and Z-score, and reference databases.

    PubMed

    Dimai, Hans P

    2017-11-01

    Dual-energy X-ray absorptiometry (DXA) is a two-dimensional imaging technology developed to assess bone mineral density (BMD) of the entire human skeleton and also specifically of skeletal sites known to be most vulnerable to fracture. In order to simplify interpretation of BMD measurement results and allow comparability among different DXA-devices, the T-score concept was introduced. This concept involves an individual's BMD which is then compared with the mean value of a young healthy reference population, with the difference expressed as a standard deviation (SD). Since the early nineties of the past century, the diagnostic categories "normal, osteopenia, and osteoporosis", as recommended by a WHO working Group, are based on this concept. Thus, DXA is still the globally accepted "gold-standard" method for the noninvasive diagnosis of osteoporosis. Another score obtained from DXA measurement, termed Z-score, describes the number of SDs by which the BMD in an individual differs from the mean value expected for age and sex. Although not intended for diagnosis of osteoporosis in adults, it nevertheless provides information about an individual's fracture risk compared to peers. DXA measurement can either be used as a "stand-alone" means in the assessment of an individual's fracture risk, or incorporated into one of the available fracture risk assessment tools such as FRAX® or Garvan, thus improving the predictive power of such tools. The issue which reference databases should be used by DXA-device manufacturers for T-score reference standards has been recently addressed by an expert group, who recommended use National Health and Nutrition Examination Survey III (NHANES III) databases for the hip reference standard but own databases for the lumbar spine. Furthermore, in men it is recommended use female reference databases for calculation of the T-score and use male reference databases for calculation of Z-score. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Can subepithelial connective tissue grafts be considered the gold standard procedure in the treatment of Miller Class I and II recession-type defects?

    PubMed

    Chambrone, Leandro; Chambrone, Daniela; Pustiglioni, Francisco E; Chambrone, Luiz A; Lima, Luiz A

    2008-09-01

    The objective of this systematic review was to answer the following question: 'Can subepithelial connective tissue grafts (SCTG) be considered the gold standard procedure in the treatment of recession-type defects?' DATA AND SOURCE: An electronic search (MEDLIINE, EMBASE and CENTRAL) for randomized controlled clinical trials with at least 6 months' follow-up comparing SCTG with other procedures for the treatment of gingival recession was performed up to December 2007. To be eligible to this review patients had to present a diagnosis of gingival recession with the following characteristics: (a) recession areas selected for treatment classified as Miller [Miller Jr PD. A classification of marginal tissue recession. International Journal of Periodontics & Restorative Dentistry 1985;5:8-13.] Class I or Class II of at least 2mm; (b) recession areas containing teeth with no caries or restorations; and (c) at least 10 participants per group at final examination. From a total of 568 references, 23 studies were considered relevant. The results indicated a statistically significant greater reduction in gingival recession for SCTG, when compared to acellular dermal matrix grafts and guided tissue regeneration with resorbable membranes (GTR rm). For clinical attachment level changes, differences between all groups were not significant. For changes in the keratinized tissue (KT), the results showed a statistically significant gain in the width of KT for SCTG when compared to GTR rm. The results of this review show that subepithelial connective tissue grafts provided significant root coverage, clinical attachment and keratinized tissue gain. Overall comparisons allow us to consider it as the 'gold standard' procedure in the treatment of recession-type defects.

  16. Coronary ostia obstruction after replacement of aortic valve prostesis

    PubMed Central

    2011-01-01

    Aortic valve replacement (AVR) is the gold standard for the treatment of severe symptomatic aortic stenosis. Complications directly related to surgical procedure are relatively infrequent. Coronary ostial stenosis is, generally, referred as late complication. Anecdotal reports concern coronary ostial stenosis as acute complication. A unique fatal case of intraoperative, bilateral coronary ostial obstruction by prosthetic valve leading to an extensive myocardial infarction is reported. Surgeons must have a high level of vigilance regarding the occurrence of acute myocardial ischemia and sudden death soon after AVR. PMID:21810231

  17. After the Gold Rush: Questioning the "Gold Standard" and Reappraising the Status of Experiment and Randomized Controlled Trials in Education

    ERIC Educational Resources Information Center

    Thomas, Gary

    2016-01-01

    The past few years have seen a resurgence of faith in experimentation in education inquiry, and particularly in randomized controlled trials (RCTs). Proponents of such research have succeeded in bringing into common parlance the term "gold standard," which suggests that research emerging from any other design frame fails to achieve the…

  18. Objective evaluation of reconstruction methods for quantitative SPECT imaging in the absence of ground truth.

    PubMed

    Jha, Abhinav K; Song, Na; Caffo, Brian; Frey, Eric C

    2015-04-13

    Quantitative single-photon emission computed tomography (SPECT) imaging is emerging as an important tool in clinical studies and biomedical research. There is thus a need for optimization and evaluation of systems and algorithms that are being developed for quantitative SPECT imaging. An appropriate objective method to evaluate these systems is by comparing their performance in the end task that is required in quantitative SPECT imaging, such as estimating the mean activity concentration in a volume of interest (VOI) in a patient image. This objective evaluation can be performed if the true value of the estimated parameter is known, i.e. we have a gold standard. However, very rarely is this gold standard known in human studies. Thus, no-gold-standard techniques to optimize and evaluate systems and algorithms in the absence of gold standard are required. In this work, we developed a no-gold-standard technique to objectively evaluate reconstruction methods used in quantitative SPECT when the parameter to be estimated is the mean activity concentration in a VOI. We studied the performance of the technique with realistic simulated image data generated from an object database consisting of five phantom anatomies with all possible combinations of five sets of organ uptakes, where each anatomy consisted of eight different organ VOIs. Results indicate that the method provided accurate ranking of the reconstruction methods. We also demonstrated the application of consistency checks to test the no-gold-standard output.

  19. Gold concentrations in abiotic materials, plants, and animals: a synoptic review

    USGS Publications Warehouse

    Eisler, R.

    2004-01-01

    Gold (Au) is ubiquitous in the environment and mined commercially at numerous locations worldwide. It is also an allergen that induces dermatitis in sensitive individuals. Gold concentrations were comparatively elevated in samples collected near gold mining and processing facilities, although no data were found for birds and non-human mammals. Maximum gold concentrations reported in abiotic materials were 0.001 ug/L in rainwater; 0.0015 ug/L in seawater near hydrothermal vents vs. <0.00004-0.0007 ug/L elsewhere; 5.0 ug/kg dry weight (DW) in the Earth's crust; 19.0 ug/L in a freshwater stream near a gold mining site; 440 ug/kg DW in atmospheric dust near a high traffic road; 843 ug/kg DW in alluvial soil near a Nevada gold mine vs. <29 ug/kg DW premining; 2.53 mg/kg DW in snow near a Russian smelter vs. <0.35 mg/kg DW at a reference site; 4.5 mg/kg DW in sewage sludge; 28.7 mg/kg DW in polymetallic sulfides from the ocean floor; and 256.0 mg/kg DW in freshwater sediments near a gold mine tailings pile vs. <5 ug/kg DW prior to mining. In plants, elevated concentrations of 19 ug Au/kg DW were reported in terrestrial vegetation near gold mining operations vs. <4 ug/kg DW at a reference site; 37 ug/kg DW in aquatic bryophytes downstream from a gold mine; 150 ug Au/kg DW in leaves of beans grown in soil containing 170 ug/kg DW; up to 1.06 mg/kg DW in algal mats of rivers receiving gold mine wastes; and 0.1-100 mg/kg DW in selected gold accumulator plants. Fish and aquatic invertebrates contained 0.1-38.0 ug Au/kg DW. In humans, gold concentrations up to 1.1 ug/L were documented in urine of dental technicians vs. 0.002-0.85 ug/L in reference populations; 2.1 ug/L in breast milk, attributed to gold dental fillings and jewelry of mothers; 1.4 mg/kg DW in hair of goldsmiths vs. a normal range of 6-880 ug/kg DW; 2.39 mg/L in whole blood of rheumatoid arthritis patients receiving gold thiol drugs to reduce inflammation (chrysotherapy) vs. a normal range of 0.2-2.0 ug/L; and 60.0 to 233.0 mg/kg fresh weight (FW) in kidneys of rheumatoid arthritis patients undergoing active chrysotherapy vs. <42.0 mg/kg FW kidney 140 months posttreatment.

  20. Allele Frequencies Net Database: Improvements for storage of individual genotypes and analysis of existing data.

    PubMed

    Santos, Eduardo Jose Melos Dos; McCabe, Antony; Gonzalez-Galarza, Faviel F; Jones, Andrew R; Middleton, Derek

    2016-03-01

    The Allele Frequencies Net Database (AFND) is a freely accessible database which stores population frequencies for alleles or genes of the immune system in worldwide populations. Herein we introduce two new tools. We have defined new classifications of data (gold, silver and bronze) to assist users in identifying the most suitable populations for their tasks. The gold standard datasets are defined by allele frequencies summing to 1, sample sizes >50 and high resolution genotyping, while silver standard datasets do not meet gold standard genotyping resolution and/or sample size criteria. The bronze standard datasets are those that could not be classified under the silver or gold standards. The gold standard includes >500 datasets covering over 3 million individuals from >100 countries at one or more of the following loci: HLA-A, -B, -C, -DPA1, -DPB1, -DQA1, -DQB1 and -DRB1 - with all loci except DPA1 present in more than 220 datasets. Three out of 12 geographic regions have low representation (the majority of their countries having less than five datasets) and the Central Asia region has no representation. There are 18 countries that are not represented by any gold standard datasets but are represented by at least one dataset that is either silver or bronze standard. We also briefly summarize the data held by AFND for KIR genes, alleles and their ligands. Our second new component is a data submission tool to assist users in the collection of the genotypes of the individuals (raw data), facilitating submission of short population reports to Human Immunology, as well as simplifying the submission of population demographics and frequency data. Copyright © 2015 American Society for Histocompatibility and Immunogenetics. Published by Elsevier Inc. All rights reserved.

  1. Pulse Wave Velocity as Marker of Preclinical Arterial Disease: Reference Levels in a Uruguayan Population Considering Wave Detection Algorithms, Path Lengths, Aging, and Blood Pressure

    PubMed Central

    Farro, Ignacio; Bia, Daniel; Zócalo, Yanina; Torrado, Juan; Farro, Federico; Florio, Lucía; Olascoaga, Alicia; Alallón, Walter; Lluberas, Ricardo; Armentano, Ricardo L.

    2012-01-01

    Carotid-femoral pulse wave velocity (PWV) has emerged as the gold standard for non-invasive evaluation of aortic stiffness; absence of standardized methodologies of study and lack of normal and reference values have limited a wider clinical implementation. This work was carried out in a Uruguayan (South American) population in order to characterize normal, reference, and threshold levels of PWV considering normal age-related changes in PWV and the prevailing blood pressure level during the study. A conservative approach was used, and we excluded symptomatic subjects; subjects with history of cardiovascular (CV) disease, diabetes mellitus or renal failure; subjects with traditional CV risk factors (other than age and gender); asymptomatic subjects with atherosclerotic plaques in carotid arteries; patients taking anti-hypertensives or lipid-lowering medications. The included subjects (n = 429) were categorized according to the age decade and the blood pressure levels (at study time). All subjects represented the “reference population”; the group of subjects with optimal/normal blood pressures levels at study time represented the “normal population.” Results. Normal and reference PWV levels were obtained. Differences in PWV levels and aging-associated changes were obtained. The obtained data could be used to define vascular aging and abnormal or disease-related arterial changes. PMID:22666551

  2. Systematic comparison of variant calling pipelines using gold standard personal exome variants

    PubMed Central

    Hwang, Sohyun; Kim, Eiru; Lee, Insuk; Marcotte, Edward M.

    2015-01-01

    The success of clinical genomics using next generation sequencing (NGS) requires the accurate and consistent identification of personal genome variants. Assorted variant calling methods have been developed, which show low concordance between their calls. Hence, a systematic comparison of the variant callers could give important guidance to NGS-based clinical genomics. Recently, a set of high-confident variant calls for one individual (NA12878) has been published by the Genome in a Bottle (GIAB) consortium, enabling performance benchmarking of different variant calling pipelines. Based on the gold standard reference variant calls from GIAB, we compared the performance of thirteen variant calling pipelines, testing combinations of three read aligners—BWA-MEM, Bowtie2, and Novoalign—and four variant callers—Genome Analysis Tool Kit HaplotypeCaller (GATK-HC), Samtools mpileup, Freebayes and Ion Proton Variant Caller (TVC), for twelve data sets for the NA12878 genome sequenced by different platforms including Illumina2000, Illumina2500, and Ion Proton, with various exome capture systems and exome coverage. We observed different biases toward specific types of SNP genotyping errors by the different variant callers. The results of our study provide useful guidelines for reliable variant identification from deep sequencing of personal genomes. PMID:26639839

  3. Diagnosis accuracy of two vision screeners for visual health surveillance of workers who use video display terminals

    PubMed Central

    Molina-Torres, María-José; Crespo, María-del-Mar Seguí; Francés, Ana Tauste; Lacarra, Blanca Lumbreras; Ronda-Pérez, Elena

    2016-01-01

    Objective: To compare the diagnostic accuracy of two vision screeners by a visual examination performed by an optometrist (gold standard) and to evaluate the concordance between both screeners and between each screener and the gold standard. Methods: This was a cross-sectional study that included computer workers who attended a routine yearly health examination. The study included administrative office workers (n=91) aged 50.2±7.9 years (mean±standard deviation), 69.2% of whom were women and 68.1% of whom used video display terminals (VDT) for >4 h/day. The routine visual examination included monocular and binocular distance visual acuity (VA), distance and near lateral phoria (LP), stereo acuity (SA), and color vision. Tests were repeated with Optec 6500 (by Stereo Optical) and Visiotest (by Essilor) screeners. Sensitivity, specificity, positive predictive values (PPV), negative predictive values (NPV), and false positive and negative rates were calculated. Kappa coefficient (κ) was used to measure the concordance of the screeners and the gold standard. Results: The sensitivity and specificity for monocular VA were over 80% for both vision screeners; PPV was below 25%. Sensitivity and specificity were lower for SA (55%-70%), PPV was 50%, and NPV was 75% for both screeners. For distance LP, sensitivity and PPV were <10% in both cases. The screeners differed in their values for near LP: Optec 6500 had higher sensitivity (43.5%), PPV (37.0%), and NPV (79.7%); whereas the Visiotest had higher specificity (83.8%). For color vision, Visiotest showed low sensitivity, low PPV, and high specificity. Visiotest obtained false positive rates that were lower or similar to Optec 6500, and both screeners obtained false negative rates below 50%. Both screeners showed poor concordance (κ<0.40). Conclusions: A high value for NPV would qualify both screeners as acceptable alternatives for visual health surveillance when used as a screening tool; patients with positive test results should be referred to a specialist. PMID:27488039

  4. 77 FR 61789 - Agency Information Collection Activities; Submission for OMB Review; Comment Request; Workforce...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-11

    ... Programs Gold Standard Evaluation Follow-Up Surveys, Veterans Study, and Cost Data,'' to the Office of... Standard Evaluation Follow-Up Surveys, Veterans Study, and Cost Data ACTION: Notice. SUMMARY: The... Worker Programs Gold Standard Evaluation Follow-Up Surveys, Veterans Study, and Cost Data. OMB ICR...

  5. Quantitative analysis of gold nanoparticles in single cells by laser ablation inductively coupled plasma-mass spectrometry.

    PubMed

    Wang, Meng; Zheng, Ling-Na; Wang, Bing; Chen, Han-Qing; Zhao, Yu-Liang; Chai, Zhi-Fang; Reid, Helen J; Sharp, Barry L; Feng, Wei-Yue

    2014-10-21

    Single cell analysis has become an important field of research in recent years reflecting the heterogeneity of cellular responses in biological systems. Here, we demonstrate a new method, based on laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS), which can quantify in situ gold nanoparticles (Au NPs) in single cells. Dried residues of picoliter droplets ejected by a commercial inkjet printer were used to simulate matrix-matched calibration standards. The gold mass in single cells exposed to 100 nM NIST Au NPs (Reference material 8012, 30 nm) for 4 h showed a log-normal distribution, ranging from 1.7 to 72 fg Au per cell, which approximately corresponds to 9 to 370 Au NPs per cell. The average result from 70 single cells (15 ± 13 fg Au per cell) was in good agreement with the result from an aqua regia digest solution of 1.2 × 10(6) cells (18 ± 1 fg Au per cell). The limit of quantification was 1.7 fg Au. This paper demonstrates the great potential of LA-ICPMS for single cell analysis and the beneficial study of biological responses to metal drugs or NPs at the single cell level.

  6. A quantitative literature-curated gold standard for kinase-substrate pairs

    PubMed Central

    2011-01-01

    We describe the Yeast Kinase Interaction Database (KID, http://www.moseslab.csb.utoronto.ca/KID/), which contains high- and low-throughput data relevant to phosphorylation events. KID includes 6,225 low-throughput and 21,990 high-throughput interactions, from greater than 35,000 experiments. By quantitatively integrating these data, we identified 517 high-confidence kinase-substrate pairs that we consider a gold standard. We show that this gold standard can be used to assess published high-throughput datasets, suggesting that it will enable similar rigorous assessments in the future. PMID:21492431

  7. [Methods for evaluating diagnostic tests in Enfermedades Infecciosas y Microbiología Clínica].

    PubMed

    Ramos, J M; Hernández, I

    1998-04-01

    In the field of infectious diseases and clinical microbiology, the evaluation of diagnostic tests (DT) is an important research area. The specific difficulties of this type of research has motivated that have not caught the severity methodological of others areas of clinical research. This article try to asses and characterize the methodology of articles about DT published in Enfermedades Infecciosas y Microbiología Clínica (EIMC) journal. Forty-five articles was selected in the EIMC journal during the 1990-1996 period, because of determinate the sensitivity and specificity of different DT. Methodological standards, extensively accepted was used. In all of articles, except one (98%) the gold standard was specified yours use, however in 4 studies (9%) include the DT in the gold standard (incorporation bias). The correct description of DT was reported in 75% of cases, but only in 11% cases the reproducibility of test was evaluated. The description of source of reference population, standard of inclusion and spectrum of composition was described in 58, 33 and 40% of articles, respectively. In 33% of studies presented workup bias, only 6% commented blind-analysis of results, and 11% presented indeterminate test results. Half of the studies reported test indexes for clinical subgroups, only one article (2%) provided numerical precision for test indexes, and only 7% reported receiver operating characteristics curves. The methodological quality of DT research in the EIMC journal may improve in different aspects of design and presentation of results.

  8. Diagnostic value of different adherence measures using electronic monitoring and virologic failure as reference standards.

    PubMed

    Deschamps, Ann E; De Geest, Sabina; Vandamme, Anne-Mieke; Bobbaers, Herman; Peetermans, Willy E; Van Wijngaerden, Eric

    2008-09-01

    Nonadherence to antiretroviral therapy is a substantial problem in HIV and jeopardizes the success of treatment. Accurate measurement of nonadherence is therefore imperative for good clinical management but no gold standard has been agreed on yet. In a single-center prospective study nonadherence was assessed by electronic monitoring: percentage of doses missed and drug holidays and by three self reports: (1) a visual analogue scale (VAS): percentage of overall doses taken; (2) the Swiss HIV Cohort Study Adherence Questionnaire (SHCS-AQ): percentage of overall doses missed and drug holidays and (3) the European HIV Treatment Questionnaire (EHTQ): percentage of doses missed and drug holidays for each antiretroviral drug separately. Virologic failure prospectively assessed during 1 year, and electronic monitoring were used as reference standards. Using virologic failure as reference standard, the best results were for (1) the SHCS-AQ after electronic monitoring (sensitivity, 87.5%; specificity, 78.6%); (2) electronic monitoring (sensitivity, 75%; specificity, 85.6%), and (3) the VAS combined with the SHCS-AQ before electronic monitoring (sensitivity, 87.5%; specificity, 58.6%). The sensitivity of the complex EHTQ was less than 50%. Asking simple questions about doses taken or missed is more sensitive than complex questioning about each drug separately. Combining the VAS with the SHCS-AQ seems a feasible nonadherence measure for daily clinical practice. Self-reports perform better after electronic monitoring: their diagnostic value could be lower when given independently.

  9. Particle size distributions by transmission electron microscopy: an interlaboratory comparison case study

    PubMed Central

    Rice, Stephen B; Chan, Christopher; Brown, Scott C; Eschbach, Peter; Han, Li; Ensor, David S; Stefaniak, Aleksandr B; Bonevich, John; Vladár, András E; Hight Walker, Angela R; Zheng, Jiwen; Starnes, Catherine; Stromberg, Arnold; Ye, Jia; Grulke, Eric A

    2015-01-01

    This paper reports an interlaboratory comparison that evaluated a protocol for measuring and analysing the particle size distribution of discrete, metallic, spheroidal nanoparticles using transmission electron microscopy (TEM). The study was focused on automated image capture and automated particle analysis. NIST RM8012 gold nanoparticles (30 nm nominal diameter) were measured for area-equivalent diameter distributions by eight laboratories. Statistical analysis was used to (1) assess the data quality without using size distribution reference models, (2) determine reference model parameters for different size distribution reference models and non-linear regression fitting methods and (3) assess the measurement uncertainty of a size distribution parameter by using its coefficient of variation. The interlaboratory area-equivalent diameter mean, 27.6 nm ± 2.4 nm (computed based on a normal distribution), was quite similar to the area-equivalent diameter, 27.6 nm, assigned to NIST RM8012. The lognormal reference model was the preferred choice for these particle size distributions as, for all laboratories, its parameters had lower relative standard errors (RSEs) than the other size distribution reference models tested (normal, Weibull and Rosin–Rammler–Bennett). The RSEs for the fitted standard deviations were two orders of magnitude higher than those for the fitted means, suggesting that most of the parameter estimate errors were associated with estimating the breadth of the distributions. The coefficients of variation for the interlaboratory statistics also confirmed the lognormal reference model as the preferred choice. From quasi-linear plots, the typical range for good fits between the model and cumulative number-based distributions was 1.9 fitted standard deviations less than the mean to 2.3 fitted standard deviations above the mean. Automated image capture, automated particle analysis and statistical evaluation of the data and fitting coefficients provide a framework for assessing nanoparticle size distributions using TEM for image acquisition. PMID:26361398

  10. Mineral resources of the Turtle Mountains Wilderness Study Area, San Bernardino County, California

    USGS Publications Warehouse

    Howard, Keith A.; Nielson, Jane E.; Simpson, Robert W.; Hazlett, Richard W.; Alminas, Henry V.; Nakata, John K.; McDonnell, John R.

    1988-01-01

    At the request of the U.S. Bureau of Land Management, approximately 105,200 acres of the Turtle Mountains Wilderness Study Area (CDCA-307) were evaluated for mineral resources (known) and resource potential (undiscovered). In this report, the area studied is referred to as "the wilderness study area" or simply "the study area"; any reference to the Turtle Mountain Wilderness Study Area refers only to that part of the wilderness study area for which a mineral survey was requested by the U.S. Bureau of Land Management.The wilderness study area is in southeastern San Bernardino County, Calif. Gold, silver, copper, and lead have been mined within and adjacent to the study area. Copper-zinc-silver-gold mineral occurrences are found in the southern part and gold-silver mineral occurrences are found in the northern part of the study area; identified low- to moderate-grade gold-silver resources occur adjacent to the study area along the western boundary. Six areas in the south-central and northwestern parts of the study area have high resource potential, two broad areas have moderate resource potential, and part of the southwest corner has low resource potential for lode gold, silver, and associated copper, lead, zinc, molybdenum, and tungsten. Alluvium locally within one of these areas has moderate resource potential for placer gold and silver, and the entire area has low resource potential for placer gold and silver. There is low resource potential for perlite, ornamental stone (onyx marble and opal), manganese, uranium and thorium, pegmatite minerals, and oil and gas within the study area. Sand and gravel are abundant but are readily available outside the wilderness study area.

  11. On Evaluating Brain Tissue Classifiers without a Ground Truth

    PubMed Central

    Martin-Fernandez, Marcos; Ungar, Lida; Nakamura, Motoaki; Koo, Min-Seong; McCarley, Robert W.; Shenton, Martha E.

    2009-01-01

    In this paper, we present a set of techniques for the evaluation of brain tissue classifiers on a large data set of MR images of the head. Due to the difficulty of establishing a gold standard for this type of data, we focus our attention on methods which do not require a ground truth, but instead rely on a common agreement principle. Three different techniques are presented: the Williams’ index, a measure of common agreement; STAPLE, an Expectation Maximization algorithm which simultaneously estimates performance parameters and constructs an estimated reference standard; and Multidimensional Scaling, a visualization technique to explore similarity data. We apply these different evaluation methodologies to a set eleven different segmentation algorithms on forty MR images. We then validate our evaluation pipeline by building a ground truth based on human expert tracings. The evaluations with and without a ground truth are compared. Our findings show that comparing classifiers without a gold standard can provide a lot of interesting information. In particular, outliers can be easily detected, strongly consistent or highly variable techniques can be readily discriminated, and the overall similarity between different techniques can be assessed. On the other hand, we also find that some information present in the expert segmentations is not captured by the automatic classifiers, suggesting that common agreement alone may not be sufficient for a precise performance evaluation of brain tissue classifiers. PMID:17532646

  12. Protocol for determining the diagnostic validity of physical examination maneuvers for shoulder pathology

    PubMed Central

    2013-01-01

    Background Shoulder complaints are the third most common musculoskeletal problem in the general population. There are an abundance of physical examination maneuvers for diagnosing shoulder pathology. The validity of these maneuvers has not been adequately addressed. We propose a large Phase III study to investigate the accuracy of these tests in an orthopaedic setting. Methods We will recruit consecutive new shoulder patients who are referred to two tertiary orthopaedic clinics. We will select which physical examination tests to include using a modified Delphi process. The physician will take a thorough history from the patient and indicate their certainty about each possible diagnosis (certain the diagnosis is absent, present or requires further testing). The clinician will only perform the physical examination maneuvers for diagnoses where uncertainty remains. We will consider arthroscopy the reference standard for patients who undergo surgery within 8 months of physical examination and magnetic resonance imaging with arthrogram for patients who do not. We will calculate the sensitivity, specificity and positive and negative likelihood ratios and investigate whether combinations of the top tests provide stronger predictions of the presence or absence of disease. Discussion There are several considerations when performing a diagnostic study to ensure that the results are applicable in a clinical setting. These include, 1) including a representative sample, 2) selecting an appropriate reference standard, 3) avoiding verification bias, 4) blinding the interpreters of the physical examination tests to the interpretation of the gold standard and, 5) blinding the interpreters of the gold standard to the interpretation of the physical examination tests. The results of this study will inform clinicians of which tests, or combination of tests, successfully reduce diagnostic uncertainty, which tests are misleading and how physical examination may affect the magnitude of the confidence the clinician feels about their diagnosis. The results of this study may reduce the number of costly and invasive imaging studies (MRI, CT or arthrography) that are requisitioned when uncertainty about diagnosis remains following history and physical exam. We also hope to reduce the variability between specialists in which maneuvers are used during physical examination and how they are used, all of which will assist in improving consistency of care between centres. PMID:23394210

  13. Effect of Nanoparticles on Modified Screen Printed Inhibition Superoxide Dismutase Electrodes for Aluminum

    PubMed Central

    Barquero-Quirós, Miriam; Arcos-Martínez, María Julia

    2016-01-01

    A novel amperometric biosensor for the determination of Al(III) based on the inhibition of the enzyme superoxide dismutase has been developed. The oxidation signal of epinephrine substrate was affected by the presence of Al(III) ions leading to a decrease in its amperometric current. The immobilization of the enzyme was performed with glutaraldehyde on screen-printed carbon electrodes modifiedwith tetrathiofulvalene (TTF) and different types ofnanoparticles. Nanoparticles of gold, platinum, rhodium and palladium were deposited on screen printed carbon electrodes by means of two electrochemical procedures. Nanoparticles were characterized trough scanning electronic microscopy, X-rays fluorescence, and atomic force microscopy. Palladium nanoparticles showed lower atomic force microscopy parameters and higher slope of aluminum calibration curves and were selected to perform sensor validation. The developed biosensor has a detection limit of 2.0 ± 0.2 μM for Al(III), with a reproducibility of 7.9% (n = 5). Recovery of standard reference material spiked to buffer solution was 103.8% with a relative standard deviation of 4.8% (n = 5). Recovery of tap water spiked with the standard reference material was 100.5 with a relative standard deviation of 3.4% (n = 3). The study of interfering ions has also been carried out. PMID:27681735

  14. Accuracy and Feasibility of an Android-Based Digital Assessment Tool for Post Stroke Visual Disorders-The StrokeVision App.

    PubMed

    Quinn, Terence J; Livingstone, Iain; Weir, Alexander; Shaw, Robert; Breckenridge, Andrew; McAlpine, Christine; Tarbert, Claire M

    2018-01-01

    Visual impairment affects up to 70% of stroke survivors. We designed an app (StrokeVision) to facilitate screening for common post stroke visual issues (acuity, visual fields, and visual inattention). We sought to describe the test time, feasibility, acceptability, and accuracy of our app-based digital visual assessments against (a) current methods used for bedside screening and (b) gold standard measures. Patients were prospectively recruited from acute stroke settings. Index tests were app-based assessments of fields and inattention performed by a trained researcher. We compared against usual clinical screening practice of visual fields to confrontation, including inattention assessment (simultaneous stimuli). We also compared app to gold standard assessments of formal kinetic perimetry (Goldman or Octopus Visual Field Assessment); and pencil and paper-based tests of inattention (Albert's, Star Cancelation, and Line Bisection). Results of inattention and field tests were adjudicated by a specialist Neuro-ophthalmologist. All assessors were masked to each other's results. Participants and assessors graded acceptability using a bespoke scale that ranged from 0 (completely unacceptable) to 10 (perfect acceptability). Of 48 stroke survivors recruited, the complete battery of index and reference tests for fields was successfully completed in 45. Similar acceptability scores were observed for app-based [assessor median score 10 (IQR: 9-10); patient 9 (IQR: 8-10)] and traditional bedside testing [assessor 10 (IQR: 9-10); patient 10 (IQR: 9-10)]. Median test time was longer for app-based testing [combined time to completion of all digital tests 420 s (IQR: 390-588)] when compared with conventional bedside testing [70 s, (IQR: 40-70)], but shorter than gold standard testing [1,260 s, (IQR: 1005-1,620)]. Compared with gold standard assessments, usual screening practice demonstrated 79% sensitivity and 82% specificity for detection of a stroke-related field defect. This compares with 79% sensitivity and 88% specificity for StrokeVision digital assessment. StrokeVision shows promise as a screening tool for visual complications in the acute phase of stroke. The app is at least as good as usual screening and offers other functionality that may make it attractive for use in acute stroke. https://ClinicalTrials.gov/ct2/show/NCT02539381.

  15. The Clinical Utility of ASRS-v1.1 for Identifying ADHD in Alcoholics Using PRISM as the Reference Standard.

    PubMed

    Reyes, Maria M; Schneekloth, Terry D; Hitschfeld, Mario J; Geske, Jennifer R; Atkinson, David L; Karpyak, Victor M

    2016-05-02

    The objective was to assess the clinical utility of the Adult ADHD Self-Report Scale (ASRS-v1.1) in identifying ADHD in alcoholics using the Psychiatric Research Interview for Substance and Mental Disorders (PRISM) as the diagnostic "gold standard." We performed a secondary analysis of data from 379 treatment-seeking alcoholics who completed the ASRS-v1.1 and the ADHD module of the PRISM. Data analysis included descriptive statistics. The prevalence of ADHD was 7.7% (95% CI = [5.4, 10.8]). The positive predictive value (PPV) of the ASRS-v1.1 was 18.1% (95% CI = [12.4, 25.7]) and the negative predictive value (NPV) was 97.6% (95% CI = [94.9, 98.9]). The ASRS-v1.1 demonstrated a sensitivity of 79.3% (95% CI = [61.6, 90.2]) and a specificity of 70.3% (95% CI = [65.3, 74.8]). The ASRS-v1.1 demonstrated acceptable sensitivity and specificity in a sample of treatment-seeking alcoholics when compared with the PRISM as the reference standard for ADHD diagnosis. © The Author(s) 2016.

  16. Living Colloidal Metal Particles from Solvated Metal Atoms. Clustering of Metal Atoms in Organic Media 15.

    DTIC Science & Technology

    1986-09-23

    alchemists , and over the centuries great medicinal powers were ascribed to gold. And as early as 300 A.D. there are references to the 2 consumption of...gold fluid to prolong life. It is doubtful that this was a colloidal solution of gold since aqua regia 3 was unknown to early Chinese alchemists , and

  17. Automated Detection of Glaucoma From Topographic Features of the Optic Nerve Head in Color Fundus Photographs.

    PubMed

    Chakrabarty, Lipi; Joshi, Gopal Datt; Chakravarty, Arunava; Raman, Ganesh V; Krishnadas, S R; Sivaswamy, Jayanthi

    2016-07-01

    To describe and evaluate the performance of an automated CAD system for detection of glaucoma from color fundus photographs. Color fundus photographs of 2252 eyes from 1126 subjects were collected from 2 centers: Aravind Eye Hospital, Madurai and Coimbatore, India. The images of 1926 eyes (963 subjects) were used to train an automated image analysis-based system, which was developed to provide a decision on a given fundus image. A total of 163 subjects were clinically examined by 2 ophthalmologists independently and their diagnostic decisions were recorded. The consensus decision was defined to be the clinical reference (gold standard). Fundus images of eyes with disagreement in diagnosis were excluded from the study. The fundus images of the remaining 314 eyes (157 subjects) were presented to 4 graders and their diagnostic decisions on the same were collected. The performance of the system was evaluated on the 314 images, using the reference standard. The sensitivity and specificity of the system and 4 independent graders were determined against the clinical reference standard. The system achieved an area under receiver operating characteristic curve of 0.792 with a sensitivity of 0.716 and specificity of 0.717 at a selected threshold for the detection of glaucoma. The agreement with the clinical reference standard as determined by Cohen κ is 0.45 for the proposed system. This is comparable to that of the image-based decisions of 4 ophthalmologists. An automated system was presented for glaucoma detection from color fundus photographs. The overall evaluation results indicated that the presented system was comparable in performance to glaucoma classification by a manual grader solely based on fundus image examination.

  18. 40 CFR 440.140 - Applicability; description of the gold placer mine subcategory.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Applicability; description of the gold... AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS ORE MINING AND DRESSING POINT SOURCE CATEGORY Gold Placer Mine Subcategory § 440.140 Applicability; description of the gold placer mine subcategory. (a) The...

  19. Role of hydrogen ions in standard and activation heap leaching of gold

    NASA Astrophysics Data System (ADS)

    Rubtsov, YuI

    2017-02-01

    The role of hydrogen ions in activation heap leaching of gold from rebellious ore has been studied, which has allowed enhancing gold recovery. The author puts forward a gold leaching circuit with the use of activated oxygen-saturated solutions acidified to pH = 6-9.

  20. Gold concentrations in abiotic materials, plants, and animals: a synoptic review.

    PubMed

    Eisler, R

    2004-01-01

    Gold (Au) is ubiquitous in the environment and mined commercially at numerous locations worldwide. It is also an allergen that induces dermatitis in sensitive individuals. Gold concentrations were comparatively elevated in samples collected near gold mining and processing facilities, although no data were found for birds and non-human mammals. Maximum gold concentrations reported in abiotic materials were 0.001 microg L(-1) in rainwater; 0.0015 microg L(-1) in seawater near hydrothermal vents vs. < 0.00004-0.0007 microg L(-1) elsewhere; 5.0 microg kg(-1) dry weight (DW) in the Earth's crust; 19.0 microg L(-1) in a freshwater stream near a gold mining site; 440 microg kg(-1) DW in atmospheric dust near a high traffic road; 843 microg kg(-1) DW in alluvial soil near a Nevada gold mine vs. < 29 microg kg(-1) DW premining; 2.53 mg kg(-1) DW in snow near a Russian smelter vs. < 0.35 mg kg(-1) DW at a reference site; 4.5 mg kg(-1) DW in sewage sludge; 28.7 mg kg(-1) DW in polymetallic sulfides from the ocean floor; and 256.0 mg kg(-1) DW in freshwater sediments near a gold mine tailings pile vs. < 5 microg kg(-1) DW prior to mining. In plants, elevated concentrations of 19 microg Au kg(-1) DW were reported in terrestrial vegetation near gold mining operations vs. < 4 microg kg(-1) DW at a reference site; 37 microg kg(-1) DW in aquatic bryophytes downstream from a gold mine; 150 microg Au kg(-1) DW in leaves of beans grown in soil containing 170 microg kg(-1) DW; up to 1.06 mg kg(-1) DW in algal mats of rivers receiving gold mine wastes; and 0.1-100 mg kg(-1) DW in selected gold accumulator plants. Fish and aquatic invertebrates contained 0.1-38.0 microg Au kg(-1) DW. In humans, gold concentrations up to 1.1 microg L(-1) were documented in urine of dental technicians vs. 0.002-0.85 microg L(-1) in reference populations; 2.1 microg L(-1) in breast milk, attributed to gold dental fillings and jewelry of mothers; 1.4 mg kg(-1) DW in hair of goldsmiths vs. a normal range of 6-880 microg kg(-1) DW; 2.39 mg L(-1) in whole blood of rheumatoid arthritis patients receiving gold thiol drugs to reduce inflammation (chrysotherapy) vs. a normal range of 0.2-2.0 microg L(-1); and 60.0 to 233.0 mg kg(-1) fresh weight (FW) in kidneys of rheumatoid arthritis patients undergoing active chrysotherapy vs. < 42.0 mg kg(-1) FW kidney 140 months posttreatment.

  1. Leishmania infection: laboratory diagnosing in the absence of a "gold standard".

    PubMed

    Rodríguez-Cortés, Alhelí; Ojeda, Ana; Francino, Olga; López-Fuertes, Laura; Timón, Marcos; Alberola, Jordi

    2010-02-01

    There is no gold standard for diagnosing leishmaniases. Our aim was to assess the operative validity of tests used in detecting Leishmania infection using samples from experimental infections, a reliable equivalent to the classic definition of gold standard. Without statistical differences, the highest sensitivity was achieved by protein A (ProtA), immunoglobulin (Ig)G2, indirect fluorescenece antibody test (IFAT), lymphocyte proliferation assay, quantitative real-time polymerase chain reaction of bone marrow (qPCR-BM), qPCR-Blood, and IgG; and the highest specificity by IgG1, IgM, IgA, qPCR-Blood, IgG, IgG2, and qPCR-BM. Maximum positive predictive value was obtained simultaneously by IgG2, qPCR-Blood, and IgG; and maximum negative predictive value by qPCR-BM. Best positive and negative likelihood ratios were obtained by IgG2. The test having the greatest, statistically significant, area under the receiver operating characteristics curve was IgG2 enzyme-linked immunosorbent assay (ELISA). Thus, according to the gold standard used, IFAT and qPCR are far from fulfilling the requirements to be considered gold standards, and the test showing the highest potential to detect Leishmania infection is Leishmania-specific ELISA IgG2.

  2. How to use… lymph node biopsy in paediatrics.

    PubMed

    Farndon, Sarah; Behjati, Sam; Jonas, Nico; Messahel, Boo

    2017-10-01

    Lymphadenopathy is a common finding in children. It often causes anxiety among parents and healthcare professionals because it can be a sign of cancer. There is limited high-quality evidence to guide clinicians as to which children should be referred for lymph node biopsy. The gold standard method for evaluating lymphadenopathy of unknown cause is an excision biopsy. In this Interpretation, we discuss the use of lymph node biopsy in children. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  3. larvalign: Aligning Gene Expression Patterns from the Larval Brain of Drosophila melanogaster.

    PubMed

    Muenzing, Sascha E A; Strauch, Martin; Truman, James W; Bühler, Katja; Thum, Andreas S; Merhof, Dorit

    2018-01-01

    The larval brain of the fruit fly Drosophila melanogaster is a small, tractable model system for neuroscience. Genes for fluorescent marker proteins can be expressed in defined, spatially restricted neuron populations. Here, we introduce the methods for 1) generating a standard template of the larval central nervous system (CNS), 2) spatial mapping of expression patterns from different larvae into a reference space defined by the standard template. We provide a manually annotated gold standard that serves for evaluation of the registration framework involved in template generation and mapping. A method for registration quality assessment enables the automatic detection of registration errors, and a semi-automatic registration method allows one to correct registrations, which is a prerequisite for a high-quality, curated database of expression patterns. All computational methods are available within the larvalign software package: https://github.com/larvalign/larvalign/releases/tag/v1.0.

  4. "Can Simple Metals Be Transmuted into Gold?" Teaching Science through a Historical Approach.

    ERIC Educational Resources Information Center

    Mamlok, Rachel; Ben-Zvi, Ruth; Menis, Joseph; Penick, John E.

    2000-01-01

    Describes the development and enactment of a new teaching unit, "Can simple metals be transmuted into gold?", through an historical approach as well as teacher preparation to teach this unit. (Contains 16 references.) (ASK)

  5. The accuracy of ultrashort echo time MRI sequences for medical additive manufacturing.

    PubMed

    van Eijnatten, Maureen; Rijkhorst, Erik-Jan; Hofman, Mark; Forouzanfar, Tymour; Wolff, Jan

    2016-01-01

    Additively manufactured bone models, implants and drill guides are becoming increasingly popular amongst maxillofacial surgeons and dentists. To date, such constructs are commonly manufactured using CT technology that induces ionizing radiation. Recently, ultrashort echo time (UTE) MRI sequences have been developed that allow radiation-free imaging of facial bones. The aim of the present study was to assess the feasibility of UTE MRI sequences for medical additive manufacturing (AM). Three morphologically different dry human mandibles were scanned using a CT and MRI scanner. Additionally, optical scans of all three mandibles were made to acquire a "gold standard". All CT and MRI scans were converted into Standard Tessellation Language (STL) models and geometrically compared with the gold standard. To quantify the accuracy of the AM process, the CT, MRI and gold-standard STL models of one of the mandibles were additively manufactured, optically scanned and compared with the original gold-standard STL model. Geometric differences between all three CT-derived STL models and the gold standard were <1.0 mm. All three MRI-derived STL models generally presented deviations <1.5 mm in the symphyseal and mandibular area. The AM process introduced minor deviations of <0.5 mm. This study demonstrates that MRI using UTE sequences is a feasible alternative to CT in generating STL models of the mandible and would therefore be suitable for surgical planning and AM. Further in vivo studies are necessary to assess the usability of UTE MRI sequences in clinical settings.

  6. Methodological Pluralism: The Gold Standard of STEM Evaluation

    ERIC Educational Resources Information Center

    Lawrenz, Frances; Huffman, Douglas

    2006-01-01

    Nationally, there is continuing debate about appropriate methods for conducting educational evaluations. The U.S. Department of Education has placed a priority on "scientifically" based evaluation methods and has advocated a "gold standard" of randomized controlled experimentation. The priority suggests that randomized control methods are best,…

  7. Advanced Placement and International Baccalaureate: Do They Deserve Gold Star Status?

    ERIC Educational Resources Information Center

    Byrd, Sheila

    2007-01-01

    For many people committed to strong academic standards, the "advanced" high school courses offered through the College Board's Advanced Placement program and, increasingly, the Diploma Programme of the International Baccalaureate Organisation (IBO) represent the curricular gold standard for secondary education. Admissions directors and…

  8. Increasing the accuracy and scalability of the Immunofluorescence Assay for Epstein Barr Virus by inferring continuous titers from a single sample dilution.

    PubMed

    Goh, Sherry Meow Peng; Swaminathan, Muthukaruppan; Lai, Julian U-Ming; Anwar, Azlinda; Chan, Soh Ha; Cheong, Ian

    2017-01-01

    High Epstein Barr Virus (EBV) titers detected by the indirect Immunofluorescence Assay (IFA) are a reliable predictor of Nasopharyngeal Carcinoma (NPC). Despite being the gold standard for serological detection of NPC, the IFA is limited by scaling bottlenecks. Specifically, 5 serial dilutions of each patient sample must be prepared and visually matched by an evaluator to one of 5 discrete titers. Here, we describe a simple method for inferring continuous EBV titers from IFA images acquired from NPC-positive patient sera using only a single sample dilution. In the first part of our study, 2 blinded evaluators used a set of reference titer standards to perform independent re-evaluations of historical samples with known titers. Besides exhibiting high inter-evaluator agreement, both evaluators were also in high concordance with historical titers, thus validating the accuracy of the reference titer standards. In the second part of the study, the reference titer standards were IFA-processed and assigned an 'EBV Score' using image analysis. A log-linear relationship between titers and EBV Score was observed. This relationship was preserved even when images were acquired and analyzed 3days post-IFA. We conclude that image analysis of IFA-processed samples can be used to infer a continuous EBV titer with just a single dilution of NPC-positive patient sera. This work opens new possibilities for improving the accuracy and scalability of IFA in the context of clinical screening. Copyright © 2016. Published by Elsevier B.V.

  9. Detecting inflammation in inflammatory bowel disease - how does ultrasound compare to magnetic resonance enterography using standardised scoring systems?

    PubMed

    Barber, Joy L; Zambrano-Perez, Alexsandra; Olsen, Øystein E; Kiparissi, Fevronia; Baycheva, Mila; Knaflez, Daniela; Shah, Neil; Watson, Tom A

    2018-06-01

    Magnetic resonance enterography (MRE) is the current gold standard for imaging in inflammatory bowel disease, but ultrasound (US) is a potential alternative. To determine whether US is as good as MRE for the detecting inflamed bowel, using a combined consensus score as the reference standard. We conducted a retrospective cohort study in children and adolescents <18 years with inflammatory bowel disease (IBD) at a tertiary and quaternary centre. We included children who underwent MRE and US within 4 weeks. We scored MRE using the London score and US using a score adapted from the METRIC (MR Enterography or Ultrasound in Crohn's Disease) trial. Four gastroenterologists assessed an independent clinical consensus score. A combined consensus score using the imaging and clinical scores was agreed upon and used as the reference standard to compare MRE with US. We included 53 children. At a whole-patient level, MRE scores were 2% higher than US scores. We used Lin coefficient to assess inter-observer variability. The repeatability of MRE scores was poor (Lin 0.6). Agreement for US scoring was substantial (Lin 0.95). There was a significant positive correlation between MRE and clinical consensus scores (Spearman's rho = 0.598, P=0.0053) and US and clinical consensus scores (Spearman's rho = 0.657, P=0.0016). US detects as much clinically significant bowel disease as MRE. It is possible that MRE overestimates the presence of disease when using a scoring system. This study demonstrates the feasibility of using a clinical consensus reference standard in paediatric IBD imaging studies.

  10. Validity and inter-observer reliability of subjective hand-arm vibration assessments.

    PubMed

    Coenen, Pieter; Formanoy, Margriet; Douwes, Marjolein; Bosch, Tim; de Kraker, Heleen

    2014-07-01

    Exposure to mechanical vibrations at work (e.g., due to handling powered tools) is a potential occupational risk as it may cause upper extremity complaints. However, reliable and valid assessment methods for vibration exposure at work are lacking. Measuring hand-arm vibration objectively is often difficult and expensive, while often used information provided by manufacturers lacks detail. Therefore, a subjective hand-arm vibration assessment method was tested on validity and inter-observer reliability. In an experimental protocol, sixteen tasks handling powered tools were executed by two workers. Hand-arm vibration was assessed subjectively by 16 observers according to the proposed subjective assessment method. As a gold standard reference, hand-arm vibration was measured objectively using a vibration measurement device. Weighted κ's were calculated to assess validity, intra-class-correlation coefficients (ICCs) were calculated to assess inter-observer reliability. Inter-observer reliability of the subjective assessments depicting the agreement among observers can be expressed by an ICC of 0.708 (0.511-0.873). The validity of the subjective assessments as compared to the gold-standard reference can be expressed by a weighted κ of 0.535 (0.285-0.785). Besides, the percentage of exact agreement of the subjective assessment compared to the objective measurement was relatively low (i.e., 52% of all tasks). This study shows that subjectively assessed hand-arm vibrations are fairly reliable among observers and moderately valid. This assessment method is a first attempt to use subjective risk assessments of hand-arm vibration. Although, this assessment method can benefit from some future improvement, it can be of use in future studies and in field-based ergonomic assessments. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  11. Validity of maximal isometric knee extension strength measurements obtained via belt-stabilized hand-held dynamometry in healthy adults.

    PubMed

    Ushiyama, Naoko; Kurobe, Yasushi; Momose, Kimito

    2017-11-01

    [Purpose] To determine the validity of knee extension muscle strength measurements using belt-stabilized hand-held dynamometry with and without body stabilization compared with the gold standard isokinetic dynamometry in healthy adults. [Subjects and Methods] Twenty-nine healthy adults (mean age, 21.3 years) were included. Study parameters involved right side measurements of maximal isometric knee extension strength obtained using belt-stabilized hand-held dynamometry with and without body stabilization and the gold standard. Measurements were performed in all subjects. [Results] A moderate correlation and fixed bias were found between measurements obtained using belt-stabilized hand-held dynamometry with body stabilization and the gold standard. No significant correlation and proportional bias were found between measurements obtained using belt-stabilized hand-held dynamometry without body stabilization and the gold standard. The strength identified using belt-stabilized hand-held dynamometry with body stabilization may not be commensurate with the maximum strength individuals can generate; however, it reflects such strength. In contrast, the strength identified using belt-stabilized hand-held dynamometry without body stabilization does not reflect the maximum strength. Therefore, a chair should be used to stabilize the body when performing measurements of maximal isometric knee extension strength using belt-stabilized hand-held dynamometry in healthy adults. [Conclusion] Belt-stabilized hand-held dynamometry with body stabilization is more convenient than the gold standard in clinical settings.

  12. Is the coverage of google scholar enough to be used alone for systematic reviews

    PubMed Central

    2013-01-01

    Background In searches for clinical trials and systematic reviews, it is said that Google Scholar (GS) should never be used in isolation, but in addition to PubMed, Cochrane, and other trusted sources of information. We therefore performed a study to assess the coverage of GS specifically for the studies included in systematic reviews and evaluate if GS was sensitive enough to be used alone for systematic reviews. Methods All the original studies included in 29 systematic reviews published in the Cochrane Database Syst Rev or in the JAMA in 2009 were gathered in a gold standard database. GS was searched for all these studies one by one to assess the percentage of studies which could have been identified by searching only GS. Results All the 738 original studies included in the gold standard database were retrieved in GS (100%). Conclusion The coverage of GS for the studies included in the systematic reviews is 100%. If the authors of the 29 systematic reviews had used only GS, no reference would have been missed. With some improvement in the research options, to increase its precision, GS could become the leading bibliographic database in medicine and could be used alone for systematic reviews. PMID:23302542

  13. [Application of EARS in early-warning of influenza pandemic in Beijing].

    PubMed

    Zhang, Dai-tao; Yang, Peng; Zhang, Yi; Zhang, Li; Peng, Xiao-min; Shi, Wei-xian; Lu, Gui-lan; Liang, Hui-jie; Liu, Yi-meng; Liu, Min; Wang, Quan-yi

    2012-06-18

    To illustrate the efficiency of cumulative sum (CUSUM) in pre-warning of the influenza peak in Beijing. CUSUM was used to analyze the data of influenza like illness (ILI), and the results of the influenza laboratory surveillance was regarded as the gold standard to judge the approaching of the influenza peak. The surveillance was launched in 421 hospitals in Beijing during the 2009 to 2010 influenza season, while the influenza laboratory surveillance was launched by 7 collaborative laboratories. From Jun. 2009 to Apr. 2010, the average ILI percentage in the 421 hospitals was 2.56%. In the study, 19 262 pharyngeal swab samples were collected from the ILI cases in 11 hospitals and 5 045 of them were tested positive for the influenza virus, with the novel swine-origin influenza A H1N1 virus dominating. After analyzing of the ILI surveillance data with CUSUM, it was found that the ILI surveillance in Beijing could make a satisfactory early warning for the approaching of the influenza peak referring to the gold standard based on the influenza laboratory results. It could give the prediction and early warning for the influenza peak efficiently and precisely, by using CUSUM to analyze the influenza surveillance data of Beijing.

  14. Surface Optical Property Measurements on Bark and Leaf Samples

    DTIC Science & Technology

    1990-12-31

    individually positionable in sample measurement position. 100% Value Absolute, or in comparison to high-reflectance evaporated gold reference sample...evaporated gold on a smooth fused silica substrate. The absolute 100% measurement requires removing the sample from the measurement position and...choice is evaporated gold on a polished glass substrate. As- already noted, SOC uses two instruments to cover the full spectral region from 0.2 to 40.0

  15. Toward a chemiresistive ammonia (NH3) gas sensor based on viral-templated gold nanoparticles embedded in polypyrrole nanowires

    NASA Astrophysics Data System (ADS)

    Yan, Yiran; Zhang, Miluo; Su, Heng Chia; Myung, Nosang V.; Haberer, Elaine D.

    2014-08-01

    Preliminary studies toward the assembly of a gold-polypyrrole (PPy) peapod-like chemiresistive ammonia (NH3) gas sensors are presented. The proposed synthesis process will use electropolymerization to embed gold nanoparticles in polypyrrole nanowires. Viral-templating of gold nanoparticles and PPy electrodeposition via cyclic voltammetry are the focus of this investigation. A gold-binding M13 bacteriophage was used as a bio-template to assemble continuous chains of gold nanoparticles on interdigitated Pt working electrodes. The dimensions of the resulting nanowire-like structures were examined and the electrical resistance measured. PPy films were electropolymerized using an interdigitated planar, Pt electrode integrated counter and reference electrode. Morphological characterization of the polymer films was completed.

  16. Population Health Metrics Research Consortium gold standard verbal autopsy validation study: design, implementation, and development of analysis datasets

    PubMed Central

    2011-01-01

    Background Verbal autopsy methods are critically important for evaluating the leading causes of death in populations without adequate vital registration systems. With a myriad of analytical and data collection approaches, it is essential to create a high quality validation dataset from different populations to evaluate comparative method performance and make recommendations for future verbal autopsy implementation. This study was undertaken to compile a set of strictly defined gold standard deaths for which verbal autopsies were collected to validate the accuracy of different methods of verbal autopsy cause of death assignment. Methods Data collection was implemented in six sites in four countries: Andhra Pradesh, India; Bohol, Philippines; Dar es Salaam, Tanzania; Mexico City, Mexico; Pemba Island, Tanzania; and Uttar Pradesh, India. The Population Health Metrics Research Consortium (PHMRC) developed stringent diagnostic criteria including laboratory, pathology, and medical imaging findings to identify gold standard deaths in health facilities as well as an enhanced verbal autopsy instrument based on World Health Organization (WHO) standards. A cause list was constructed based on the WHO Global Burden of Disease estimates of the leading causes of death, potential to identify unique signs and symptoms, and the likely existence of sufficient medical technology to ascertain gold standard cases. Blinded verbal autopsies were collected on all gold standard deaths. Results Over 12,000 verbal autopsies on deaths with gold standard diagnoses were collected (7,836 adults, 2,075 children, 1,629 neonates, and 1,002 stillbirths). Difficulties in finding sufficient cases to meet gold standard criteria as well as problems with misclassification for certain causes meant that the target list of causes for analysis was reduced to 34 for adults, 21 for children, and 10 for neonates, excluding stillbirths. To ensure strict independence for the validation of methods and assessment of comparative performance, 500 test-train datasets were created from the universe of cases, covering a range of cause-specific compositions. Conclusions This unique, robust validation dataset will allow scholars to evaluate the performance of different verbal autopsy analytic methods as well as instrument design. This dataset can be used to inform the implementation of verbal autopsies to more reliably ascertain cause of death in national health information systems. PMID:21816095

  17. Accurate determination of arsenic in arsenobetaine standard solutions of BCR-626 and NMIJ CRM 7901-a by neutron activation analysis coupled with internal standard method.

    PubMed

    Miura, Tsutomu; Chiba, Koichi; Kuroiwa, Takayoshi; Narukawa, Tomohiro; Hioki, Akiharu; Matsue, Hideaki

    2010-09-15

    Neutron activation analysis (NAA) coupled with an internal standard method was applied for the determination of As in the certified reference material (CRM) of arsenobetaine (AB) standard solutions to verify their certified values. Gold was used as an internal standard to compensate for the difference of the neutron exposure in an irradiation capsule and to improve the sample-to-sample repeatability. Application of the internal standard method significantly improved linearity of the calibration curve up to 1 microg of As, too. The analytical reliability of the proposed method was evaluated by k(0)-standardization NAA. The analytical results of As in AB standard solutions of BCR-626 and NMIJ CRM 7901-a were (499+/-55)mgkg(-1) (k=2) and (10.16+/-0.15)mgkg(-1) (k=2), respectively. These values were found to be 15-20% higher than the certified values. The between-bottle variation of BCR-626 was much larger than the expanded uncertainty of the certified value, although that of NMIJ CRM 7901-a was almost negligible. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  18. Site-Specific Attachment of gold Nanoparticles to DNA Templates

    DTIC Science & Technology

    2001-01-01

    1 -ethyl- 3 -( 3 - dimethylaminopropyl ) carbodiimide hydrochloride (Pierce) and -2.0rmg N...functionalized gold nanoparticles. The gold particles were covalently bound to the amino groups on the DNA using standard 1 -ethyl- 3 - ( 3 - dimethylaminopropyl ...nm). The reaction between the amino group on the DNA and the carboxyl group on the gold particle was facilitated by 1 -ethyl- 3 -( 3 - dimethylaminopropyl

  19. Kinematics of the Normal Knee during Dynamic Activities: A Synthesis of Data from Intracortical Pins and Biplane Imaging

    PubMed Central

    Gasparutto, Xavier; Moissenet, Florent; Lafon, Yoann

    2017-01-01

    Few studies have provided in vivo tibiofemoral kinematics of the normal knee during dynamic weight-bearing activities. Indeed, gold standard measurement methods (i.e., intracortical pins and biplane imaging) raise ethical and experimental issues. Moreover, the conventions used for the processing of the kinematics show large inconsistencies. This study aims at synthesising the tibiofemoral kinematics measured with gold standard measurement methods. Published kinematic data were transformed in the standard recommended by the International Society of Biomechanics (ISB), and a clustering method was applied to investigate whether the couplings between the degrees of freedom (DoFs) are consistent among the different activities and measurement methods. The synthesised couplings between the DoFs during knee flexion (from 4° of extension to −61° of flexion) included abduction (up to −10°); internal rotation (up to 15°); and medial (up to 10 mm), anterior (up to 25 mm), and proximal (up to 28 mm) displacements. These synthesised couplings appeared mainly partitioned into two clusters that featured all the dynamic weight-bearing activities and all the measurement methods. Thus, the effect of the dynamic activities on the couplings between the tibiofemoral DoFs appeared to be limited. The synthesised data might be used as a reference of normal in vivo knee kinematics for prosthetic and orthotic design and for knee biomechanical model development and validation. PMID:28487620

  20. Leishmania Infection: Laboratory Diagnosing in the Absence of a “Gold Standard”

    PubMed Central

    Rodríguez-Cortés, Alhelí; Ojeda, Ana; Francino, Olga; López-Fuertes, Laura; Timón, Marcos; Alberola, Jordi

    2010-01-01

    There is no gold standard for diagnosing leishmaniases. Our aim was to assess the operative validity of tests used in detecting Leishmania infection using samples from experimental infections, a reliable equivalent to the classic definition of gold standard. Without statistical differences, the highest sensitivity was achieved by protein A (ProtA), immunoglobulin (Ig)G2, indirect fluorescenece antibody test (IFAT), lymphocyte proliferation assay, quantitative real-time polymerase chain reaction of bone marrow (qPCR-BM), qPCR-Blood, and IgG; and the highest specificity by IgG1, IgM, IgA, qPCR-Blood, IgG, IgG2, and qPCR-BM. Maximum positive predictive value was obtained simultaneously by IgG2, qPCR-Blood, and IgG; and maximum negative predictive value by qPCR-BM. Best positive and negative likelihood ratios were obtained by IgG2. The test having the greatest, statistically significant, area under the receiver operating characteristics curve was IgG2 enzyme-linked immunosorbent assay (ELISA). Thus, according to the gold standard used, IFAT and qPCR are far from fulfilling the requirements to be considered gold standards, and the test showing the highest potential to detect Leishmania infection is Leishmania-specific ELISA IgG2. PMID:20134001

  1. High Temperature Electronics Technology

    DTIC Science & Technology

    1984-05-01

    the hidrogen in the gold layer apparently was successful in suppressing the gold crystal growth. Since tape tests removed almost none of the...with others in the industry is that gold adhz-#s well to Ti-W. This refers to the undoped (no nitrogen stuffing) variety not the Ti-W diffusion...passivaiion film. The keys to v’. success were the production of a dense, slightly compreveive film, deposited at a temperature less than 330* C and the

  2. The Genomes OnLine Database (GOLD) v.5: a metadata management system based on a four level (meta)genome project classification

    PubMed Central

    Reddy, T.B.K.; Thomas, Alex D.; Stamatis, Dimitri; Bertsch, Jon; Isbandi, Michelle; Jansson, Jakob; Mallajosyula, Jyothi; Pagani, Ioanna; Lobos, Elizabeth A.; Kyrpides, Nikos C.

    2015-01-01

    The Genomes OnLine Database (GOLD; http://www.genomesonline.org) is a comprehensive online resource to catalog and monitor genetic studies worldwide. GOLD provides up-to-date status on complete and ongoing sequencing projects along with a broad array of curated metadata. Here we report version 5 (v.5) of the database. The newly designed database schema and web user interface supports several new features including the implementation of a four level (meta)genome project classification system and a simplified intuitive web interface to access reports and launch search tools. The database currently hosts information for about 19 200 studies, 56 000 Biosamples, 56 000 sequencing projects and 39 400 analysis projects. More than just a catalog of worldwide genome projects, GOLD is a manually curated, quality-controlled metadata warehouse. The problems encountered in integrating disparate and varying quality data into GOLD are briefly highlighted. GOLD fully supports and follows the Genomic Standards Consortium (GSC) Minimum Information standards. PMID:25348402

  3. Decision-Assist and Closed-Loop Control of Fluid Therapy

    DTIC Science & Technology

    2012-03-30

    achieve target endpoints while reducing fluid needs in experimental models of hemorrhage. During the previous funding cycle, along with our... IABP ) (standard of care blood pressure monitor "gold standard") in cardiac surgical patients to blood pressure recorded by the WVSM. Rational for...WVSM vs Gold standard IABP 2) History of neuropraxia 3) Refusal to consent 4) Failure to obtain radial artery cannulation Ten CPB Patients were

  4. Technical Note: Modification of the standard gain correction algorithm to compensate for the number of used reference flat frames in detector performance studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Konstantinidis, Anastasios C.; Olivo, Alessandro; Speller, Robert D.

    2011-12-15

    Purpose: The x-ray performance evaluation of digital x-ray detectors is based on the calculation of the modulation transfer function (MTF), the noise power spectrum (NPS), and the resultant detective quantum efficiency (DQE). The flat images used for the extraction of the NPS should not contain any fixed pattern noise (FPN) to avoid contamination from nonstochastic processes. The ''gold standard'' method used for the reduction of the FPN (i.e., the different gain between pixels) in linear x-ray detectors is based on normalization with an average reference flat-field. However, the noise in the corrected image depends on the number of flat framesmore » used for the average flat image. The aim of this study is to modify the standard gain correction algorithm to make it independent on the used reference flat frames. Methods: Many publications suggest the use of 10-16 reference flat frames, while other studies use higher numbers (e.g., 48 frames) to reduce the propagated noise from the average flat image. This study quantifies experimentally the effect of the number of used reference flat frames on the NPS and DQE values and appropriately modifies the gain correction algorithm to compensate for this effect. Results: It is shown that using the suggested gain correction algorithm a minimum number of reference flat frames (i.e., down to one frame) can be used to eliminate the FPN from the raw flat image. This saves computer memory and time during the x-ray performance evaluation. Conclusions: The authors show that the method presented in the study (a) leads to the maximum DQE value that one would have by using the conventional method and very large number of frames and (b) has been compared to an independent gain correction method based on the subtraction of flat-field images, leading to identical DQE values. They believe this provides robust validation of the proposed method.« less

  5. Inspecting Cases against Revans' "Gold Standard" of Action Learning

    ERIC Educational Resources Information Center

    Willis, Verna J.

    2004-01-01

    A purposive sampling and analysis of ten case histories of action learning in the US suggests that applications tend to be partial, hierarchical, and leader controlled, thus running counter in several significant ways to the gold standard of Revans' action learning theory and egalitarian rules of engagement. Using critical markers to inspect the…

  6. Seeking a Valid Gold Standard for an Innovative, Dialect-Neutral Language Test

    ERIC Educational Resources Information Center

    Pearson, Barbara Zurer; Jackson, Janice E.; Wu, Haotian

    2014-01-01

    Purpose: In this study, the authors explored alternative gold standards to validate an innovative, dialect-neutral language assessment. Method: Participants were 78 African American children, ages 5;0 (years;months) to 6;11. Twenty participants had previously been identified as having language impairment. The Diagnostic Evaluation of Language…

  7. Reassessing RCTs as the "Gold Standard": Synergy Not Separatism in Evaluation Designs

    ERIC Educational Resources Information Center

    Hanley, Pam; Chambers, Bette; Haslam, Jonathan

    2016-01-01

    Randomised controlled trials (RCTs) are increasingly used to evaluate educational interventions in the UK. However, RCTs remain controversial for some elements of the research community. This paper argues that the widespread use of the term "gold standard" to describe RCTs is problematic, as it implies that other research methods are…

  8. NAEP: Gold Standard or Fool's Gold?

    ERIC Educational Resources Information Center

    Popham, W. James

    2005-01-01

    Results of tests of students' skills and knowledge conducted by the National Assessment of Educational Progress (NAEP) and the state accountability tests required by the No Child Left Behind (NCLB) program should not be compared. The two tests are based on different standards and have different measurement functions and judging the results of one…

  9. Trace level voltammetric determination of heavy metals and total mercury in tea matrices (Camellia sinensis).

    PubMed

    Melucci, Dora; Locatelli, Marcello; Locatelli, Clinio

    2013-12-01

    An analytical procedure regarding the voltammetric determination of mercury(II), copper(II), lead(II), cadmium(II) and zinc(II) by square wave anodic stripping voltammetry (SWASV) in matrices involved in food chain is proposed. In particular, tea leaves were analyzed as real samples. The digestion of each matrix was carried out using a concentrated HCl-HNO3-H2SO4 acidic attack mixture; 0.01 mol L(-1) EDTA-Na2+ 0.15 mol L(-1) NaCl + 0.5 mol L(-1) HCl was employed as the supporting electrolyte. The voltammetric measurements were carried out using a conventional three electrode cell, employing, as working electrodes, a gold electrode (GE) and a stationary hanging mercury drop electrode (HMDE). The analytical procedure has been verified on the standard reference materials Spinach Leaves NIST-SRM 1570a, Tomato Leaves NIST-SRM 1573a and Apple Leaves NIST-SRM 1515. For all the elements, the precision as repeatability, expressed as relative standard deviation (sr) was of the order of 3-5%, while the trueness, expressed as relative error (e) was of the order of 3-7%. Once set up on the standard reference materials, the analytical procedure was applied to commercial tea leaves samples. A critical comparison with spectroscopic measurements is also discussed.

  10. Potential for improved radiation thermometry measurement uncertainty through implementing a primary scale in an industrial laboratory

    NASA Astrophysics Data System (ADS)

    Willmott, Jon R.; Lowe, David; Broughton, Mick; White, Ben S.; Machin, Graham

    2016-09-01

    A primary temperature scale requires realising a unit in terms of its definition. For high temperature radiation thermometry in terms of the International Temperature Scale of 1990 this means extrapolating from the signal measured at the freezing temperature of gold, silver or copper using Planck’s radiation law. The difficulty in doing this means that primary scales above 1000 °C require specialist equipment and careful characterisation in order to achieve the extrapolation with sufficient accuracy. As such, maintenance of the scale at high temperatures is usually only practicable for National Metrology Institutes, and calibration laboratories have to rely on a scale calibrated against transfer standards. At lower temperatures it is practicable for an industrial calibration laboratory to have its own primary temperature scale, which reduces the number of steps between the primary scale and end user. Proposed changes to the SI that will introduce internationally accepted high temperature reference standards might make it practicable to have a primary high temperature scale in a calibration laboratory. In this study such a scale was established by calibrating radiation thermometers directly to high temperature reference standards. The possible reduction in uncertainty to an end user as a result of the reduced calibration chain was evaluated.

  11. A novel in situ electrochemical NMR cell with a palisade gold film electrode

    NASA Astrophysics Data System (ADS)

    Ni, Zu-Rong; Cui, Xiao-Hong; Cao, Shuo-Hui; Chen, Zhong

    2017-08-01

    In situ electrochemical nuclear magnetic resonance (EC-NMR) has attracted considerable attention because of its ability to directly observe real-time electrochemical processes. Therefore, minimizing the incompatibility between the electrochemical device and NMR detection has become an important challenge. A circular thin metal film deposited on the outer surface of a glass tube with a thickness considerably less than the metal skin depth is considered to be the ideal working electrode. In this study, we demonstrate that such a thin film electrode still has a great influence on the radio frequency field homogeneity in the detective zone of the NMR spectrometer probe and provide theoretical and experimental confirmation of its electromagnetic shielding. Furthermore, we propose a novel palisade gold film device to act as the working electrode. The NMR nutation behavior of protons shows that the uniformity of the radio frequency field is greatly improved, increasing the sensitivity in NMR detection. Another advantage of the proposed device is that an external reference standard adapted to the reaction compound can be inserted as a probe to determine the fluctuation of the physico-chemical environment and achieve high-accuracy quantitative NMR analysis. A three-chamber electrochemical device based on the palisade gold film design was successfully fabricated and the in situ electrochemical NMR performance was validated in a standard 5 mm NMR probe by acquiring voltammograms and high-resolution NMR spectra to characterize the electrochemically generated species. The evolution of in situ EC-NMR spectrum monitoring of the redox transformation between p-benzoquinone and hydroquinone demonstrates the ability of the EC-NMR device to simultaneously quantitatively determine the reactants and elucidate the reaction mechanism at the molecular level.

  12. A Brief Assessment of Learning for Orphaned and Abandoned Children in Low and Middle Income Countries

    PubMed Central

    O’Donnell, Karen; Murphy, Robert; Ostermann, Jan; Masnick, Max; Whetten, Rachel A.; Madden, Elisabeth; Thielman, Nathan M.; Whetten, Kathryn

    2013-01-01

    Assessment of children’s learning and performance in low and middle income countries has been critiqued as lacking a gold standard, an appropriate norm reference group, and demonstrated applicability of assessment tasks to the context. This study was designed to examine the performance of three nonverbal and one adapted verbal measure of children’s problem solving, memory, motivation, and attention across five culturally diverse sites. The goal was to evaluate the tests as indicators of individual differences affected by life events and care circumstances for vulnerable children. We conclude that the measures can be successfully employed with fidelity in non-standard settings in LMICs, and are associated with child age and educational experience across the settings. The tests can be useful in evaluating variability in vulnerable child outcomes. PMID:21538088

  13. Patterning of oxide-hardened gold black by photolithography and metal lift-off

    Treesearch

    Deep Panjwani; Mehmet Yesiltas; Janardan Nath; D.E. Maukonen; Imen Rezadad; Evan M. Smith; R.E. Peale; Carol Hirschmugl; Julia Sedlmair; Ralf Wehlitz; Miriam Unger; Glenn Boreman

    2014-01-01

    A method to pattern infrared-absorbing gold black by conventional photolithography and lift-off is described. A photo-resist pattern is developed on a substrate by standard photolithography. Gold black is deposited over the whole by thermal evaporation in an inert gas at

  14. Imperfect Gold Standards for Kidney Injury Biomarker Evaluation

    PubMed Central

    Betensky, Rebecca A.; Emerson, Sarah C.; Bonventre, Joseph V.

    2012-01-01

    Clinicians have used serum creatinine in diagnostic testing for acute kidney injury for decades, despite its imperfect sensitivity and specificity. Novel tubular injury biomarkers may revolutionize the diagnosis of acute kidney injury; however, even if a novel tubular injury biomarker is 100% sensitive and 100% specific, it may appear inaccurate when using serum creatinine as the gold standard. Acute kidney injury, as defined by serum creatinine, may not reflect tubular injury, and the absence of changes in serum creatinine does not assure the absence of tubular injury. In general, the apparent diagnostic performance of a biomarker depends not only on its ability to detect injury, but also on disease prevalence and the sensitivity and specificity of the imperfect gold standard. Assuming that, at a certain cutoff value, serum creatinine is 80% sensitive and 90% specific and disease prevalence is 10%, a new perfect biomarker with a true 100% sensitivity may seem to have only 47% sensitivity compared with serum creatinine as the gold standard. Minimizing misclassification by using more strict criteria to diagnose acute kidney injury will reduce the error when evaluating the performance of a biomarker under investigation. Apparent diagnostic errors using a new biomarker may be a reflection of errors in the imperfect gold standard itself, rather than poor performance of the biomarker. The results of this study suggest that small changes in serum creatinine alone should not be used to define acute kidney injury in biomarker or interventional studies. PMID:22021710

  15. The gene normalization task in BioCreative III

    PubMed Central

    2011-01-01

    Background We report the Gene Normalization (GN) challenge in BioCreative III where participating teams were asked to return a ranked list of identifiers of the genes detected in full-text articles. For training, 32 fully and 500 partially annotated articles were prepared. A total of 507 articles were selected as the test set. Due to the high annotation cost, it was not feasible to obtain gold-standard human annotations for all test articles. Instead, we developed an Expectation Maximization (EM) algorithm approach for choosing a small number of test articles for manual annotation that were most capable of differentiating team performance. Moreover, the same algorithm was subsequently used for inferring ground truth based solely on team submissions. We report team performance on both gold standard and inferred ground truth using a newly proposed metric called Threshold Average Precision (TAP-k). Results We received a total of 37 runs from 14 different teams for the task. When evaluated using the gold-standard annotations of the 50 articles, the highest TAP-k scores were 0.3297 (k=5), 0.3538 (k=10), and 0.3535 (k=20), respectively. Higher TAP-k scores of 0.4916 (k=5, 10, 20) were observed when evaluated using the inferred ground truth over the full test set. When combining team results using machine learning, the best composite system achieved TAP-k scores of 0.3707 (k=5), 0.4311 (k=10), and 0.4477 (k=20) on the gold standard, representing improvements of 12.4%, 21.8%, and 26.6% over the best team results, respectively. Conclusions By using full text and being species non-specific, the GN task in BioCreative III has moved closer to a real literature curation task than similar tasks in the past and presents additional challenges for the text mining community, as revealed in the overall team results. By evaluating teams using the gold standard, we show that the EM algorithm allows team submissions to be differentiated while keeping the manual annotation effort feasible. Using the inferred ground truth we show measures of comparative performance between teams. Finally, by comparing team rankings on gold standard vs. inferred ground truth, we further demonstrate that the inferred ground truth is as effective as the gold standard for detecting good team performance. PMID:22151901

  16. The gene normalization task in BioCreative III.

    PubMed

    Lu, Zhiyong; Kao, Hung-Yu; Wei, Chih-Hsuan; Huang, Minlie; Liu, Jingchen; Kuo, Cheng-Ju; Hsu, Chun-Nan; Tsai, Richard Tzong-Han; Dai, Hong-Jie; Okazaki, Naoaki; Cho, Han-Cheol; Gerner, Martin; Solt, Illes; Agarwal, Shashank; Liu, Feifan; Vishnyakova, Dina; Ruch, Patrick; Romacker, Martin; Rinaldi, Fabio; Bhattacharya, Sanmitra; Srinivasan, Padmini; Liu, Hongfang; Torii, Manabu; Matos, Sergio; Campos, David; Verspoor, Karin; Livingston, Kevin M; Wilbur, W John

    2011-10-03

    We report the Gene Normalization (GN) challenge in BioCreative III where participating teams were asked to return a ranked list of identifiers of the genes detected in full-text articles. For training, 32 fully and 500 partially annotated articles were prepared. A total of 507 articles were selected as the test set. Due to the high annotation cost, it was not feasible to obtain gold-standard human annotations for all test articles. Instead, we developed an Expectation Maximization (EM) algorithm approach for choosing a small number of test articles for manual annotation that were most capable of differentiating team performance. Moreover, the same algorithm was subsequently used for inferring ground truth based solely on team submissions. We report team performance on both gold standard and inferred ground truth using a newly proposed metric called Threshold Average Precision (TAP-k). We received a total of 37 runs from 14 different teams for the task. When evaluated using the gold-standard annotations of the 50 articles, the highest TAP-k scores were 0.3297 (k=5), 0.3538 (k=10), and 0.3535 (k=20), respectively. Higher TAP-k scores of 0.4916 (k=5, 10, 20) were observed when evaluated using the inferred ground truth over the full test set. When combining team results using machine learning, the best composite system achieved TAP-k scores of 0.3707 (k=5), 0.4311 (k=10), and 0.4477 (k=20) on the gold standard, representing improvements of 12.4%, 21.8%, and 26.6% over the best team results, respectively. By using full text and being species non-specific, the GN task in BioCreative III has moved closer to a real literature curation task than similar tasks in the past and presents additional challenges for the text mining community, as revealed in the overall team results. By evaluating teams using the gold standard, we show that the EM algorithm allows team submissions to be differentiated while keeping the manual annotation effort feasible. Using the inferred ground truth we show measures of comparative performance between teams. Finally, by comparing team rankings on gold standard vs. inferred ground truth, we further demonstrate that the inferred ground truth is as effective as the gold standard for detecting good team performance.

  17. Advances in spectroscopic methods for quantifying soil carbon

    USGS Publications Warehouse

    Liebig, Mark; Franzluebbers, Alan J.; Follett, Ronald F.; Hively, W. Dean; Reeves, James B.; McCarty, Gregory W.; Calderon, Francisco

    2012-01-01

    The gold standard for soil C determination is combustion. However, this method requires expensive consumables, is limited to the determination of the total carbon and in the number of samples which can be processed (~100/d). With increased interest in soil C sequestration, faster methods are needed. Thus, interest in methods based on diffuse reflectance spectroscopy in the visible, near-infrared or mid-infrared ranges using either proximal or remote sensing. These methods have the ability to analyze more samples (2 to 3X/d) or huge areas (imagery) and do multiple analytes simultaneously, but require calibrations relating spectral and reference data and have specific problems, i.e., remote sensing is capable of scanning entire watersheds, thus reducing the sampling needed, but is limiting to the surface layer of tilled soils and by difficulty in obtaining proper calibration reference values. The objective of this discussion is the present state of spectroscopic methods for soil C determination.

  18. Mechanistic Investigations of Branched Macromolecules and Metal Nanocomposites for Nonlinear Optical Applications

    DTIC Science & Technology

    2009-09-26

    gold which show a band gap opening. them with alkyl or aryl thiolates and they are often referred as monolayer protected gold clusters (MPC...workers16-18, as well as Tsukuda and co-workers19 with several thiolate capped MPCs. The PI’s laboratory has observed luminescence mainly in the near...properties for sizes between ~50 and ~1000 atoms is not well understood. Careful analysis of absorption spectra for thiolate stabilized gold MPC

  19. 40 CFR 63.11640 - Am I subject to this subpart?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) National Emission Standards for Hazardous Air Pollutants: Gold Mine Ore Processing and Production Area... subject to this subpart if you own or operate a gold mine ore processing and production facility as... source. The affected sources are each collection of “ore pretreatment processes” at a gold mine ore...

  20. 40 CFR 63.11640 - Am I subject to this subpart?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) National Emission Standards for Hazardous Air Pollutants: Gold Mine Ore Processing and Production Area... subject to this subpart if you own or operate a gold mine ore processing and production facility as... source. The affected sources are each collection of “ore pretreatment processes” at a gold mine ore...

  1. 40 CFR 63.11640 - Am I subject to this subpart?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) National Emission Standards for Hazardous Air Pollutants: Gold Mine Ore Processing and Production Area... subject to this subpart if you own or operate a gold mine ore processing and production facility as... source. The affected sources are each collection of “ore pretreatment processes” at a gold mine ore...

  2. 40 CFR 63.11640 - Am I subject to this subpart?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) National Emission Standards for Hazardous Air Pollutants: Gold Mine Ore Processing and Production Area... subject to this subpart if you own or operate a gold mine ore processing and production facility as... source. The affected sources are each collection of “ore pretreatment processes” at a gold mine ore...

  3. 40 CFR 440.140 - Applicability; description of the gold placer mine subcategory.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS ORE MINING AND DRESSING POINT SOURCE CATEGORY Gold... gold bearing ores from placer deposits; and (2) The beneficiation processes which use gravity... applicable to any mines or beneficiation processes which process less than 1500 cubic yards (cu yd) of ore...

  4. The Trouble with the Gold Standard: School Libraries & Research

    ERIC Educational Resources Information Center

    Gordon, Carol

    2007-01-01

    Although science has provided empirical evidence for centuries, it's only as recently as the 1940s that a scientific method called randomized controlled trials (RCT) emerged as a technique to test the efficacy of drugs and medical procedures. Since RCT is unique in that it can claim causality, it's considered the "gold standard" of research…

  5. Preschoolers Explore Greenhouses by Visiting a Greenhouse, Making a Model, and Growing Plants

    ERIC Educational Resources Information Center

    Perkins, Leann M.; Stoycheva, Dessy

    2016-01-01

    This practical lesson on greenhouses implements standards of the Next Generation Science Standards ("K-2 ETS I-2"; "K-LS1-1") and the preschool objectives from the Teaching Strategies GOLD. Teaching Strategies GOLD is an assessment tool available online and in print that can be used with any developmentally appropriate early…

  6. Validating Automated Essay Scoring: A (Modest) Refinement of the "Gold Standard"

    ERIC Educational Resources Information Center

    Powers, Donald E.; Escoffery, David S.; Duchnowski, Matthew P.

    2015-01-01

    By far, the most frequently used method of validating (the interpretation and use of) automated essay scores has been to compare them with scores awarded by human raters. Although this practice is questionable, human-machine agreement is still often regarded as the "gold standard." Our objective was to refine this model and apply it to…

  7. Evaluating the Gold Standard: A Review and Meta-Analysis of the Structured Interview of Reported Symptoms

    ERIC Educational Resources Information Center

    Green, Debbie; Rosenfeld, Barry

    2011-01-01

    The Structured Interview of Reported Symptoms (SIRS; Rogers, Bagby, & Dickens, 1992) is often touted as the gold standard of measures of feigning. This label likely arises in part out of the impressive accuracy rates reported in the extensive validation research that preceded its publication. However, since its publication, researchers not only…

  8. Back-surface gold mirrors for vibrationally resonant sum-frequency (VR-SFG) spectroscopy using 3-mercaptopropyltrimethoxysilane as an adhesion promoter.

    PubMed

    Quast, Arthur D; Zhang, Feng; Linford, Matthew R; Patterson, James E

    2011-06-01

    Back-surface mirrors are needed as reference materials for vibrationally resonant sum-frequency generation (VR-SFG) probing of liquid-solid interfaces. Conventional noble metal mirrors are not suitable for back-surface applications due to the presence of a metal adhesion layer (chromium or titanium) between the window substrate and the reflective metal surface. Using vapor deposited 3-mercaptopropyltrimethoxysilane (MPTMS) as a bi-functional adhesion promoter, gold mirrors were fabricated on fused silica substrates. These mirrors exhibit excellent gold adhesion as determined by the Scotch(®) tape test. They also produce minimal spectroscopic interference in the C-H stretching region (2800-3000 cm(-1)), as characterized by VR-SFG. These mirrors are thus robust and can be used as back-surface mirrors for a variety of applications, including reference mirrors for VR-SFG.

  9. eMethylsorb: electrochemical quantification of DNA methylation at CpG resolution using DNA-gold affinity interactions.

    PubMed

    Sina, Abu Ali Ibn; Howell, Sidney; Carrascosa, Laura G; Rauf, Sakandar; Shiddiky, Muhammad J A; Trau, Matt

    2014-11-07

    We report a simple electrochemical method referred to as "eMethylsorb" for the detection of DNA methylation. The method relies on the base dependent affinity interaction of DNA with gold. The methylation status of DNA is quantified by monitoring the electrochemical current as a function of the relative adsorption level of bisulphite treated DNA samples onto a bare gold electrode. This method can successfully distinguish methylated and unmethylated epigenotypes at single CpG resolution.

  10. Solving the Problem: Genome Annotation Standards before the Data Deluge.

    PubMed

    Klimke, William; O'Donovan, Claire; White, Owen; Brister, J Rodney; Clark, Karen; Fedorov, Boris; Mizrachi, Ilene; Pruitt, Kim D; Tatusova, Tatiana

    2011-10-15

    The promise of genome sequencing was that the vast undiscovered country would be mapped out by comparison of the multitude of sequences available and would aid researchers in deciphering the role of each gene in every organism. Researchers recognize that there is a need for high quality data. However, different annotation procedures, numerous databases, and a diminishing percentage of experimentally determined gene functions have resulted in a spectrum of annotation quality. NCBI in collaboration with sequencing centers, archival databases, and researchers, has developed the first international annotation standards, a fundamental step in ensuring that high quality complete prokaryotic genomes are available as gold standard references. Highlights include the development of annotation assessment tools, community acceptance of protein naming standards, comparison of annotation resources to provide consistent annotation, and improved tracking of the evidence used to generate a particular annotation. The development of a set of minimal standards, including the requirement for annotated complete prokaryotic genomes to contain a full set of ribosomal RNAs, transfer RNAs, and proteins encoding core conserved functions, is an historic milestone. The use of these standards in existing genomes and future submissions will increase the quality of databases, enabling researchers to make accurate biological discoveries.

  11. Solving the Problem: Genome Annotation Standards before the Data Deluge

    PubMed Central

    Klimke, William; O'Donovan, Claire; White, Owen; Brister, J. Rodney; Clark, Karen; Fedorov, Boris; Mizrachi, Ilene; Pruitt, Kim D.; Tatusova, Tatiana

    2011-01-01

    The promise of genome sequencing was that the vast undiscovered country would be mapped out by comparison of the multitude of sequences available and would aid researchers in deciphering the role of each gene in every organism. Researchers recognize that there is a need for high quality data. However, different annotation procedures, numerous databases, and a diminishing percentage of experimentally determined gene functions have resulted in a spectrum of annotation quality. NCBI in collaboration with sequencing centers, archival databases, and researchers, has developed the first international annotation standards, a fundamental step in ensuring that high quality complete prokaryotic genomes are available as gold standard references. Highlights include the development of annotation assessment tools, community acceptance of protein naming standards, comparison of annotation resources to provide consistent annotation, and improved tracking of the evidence used to generate a particular annotation. The development of a set of minimal standards, including the requirement for annotated complete prokaryotic genomes to contain a full set of ribosomal RNAs, transfer RNAs, and proteins encoding core conserved functions, is an historic milestone. The use of these standards in existing genomes and future submissions will increase the quality of databases, enabling researchers to make accurate biological discoveries. PMID:22180819

  12. Mould routine identification in the clinical laboratory by matrix-assisted laser desorption ionization time-of-flight mass spectrometry.

    PubMed

    Cassagne, Carole; Ranque, Stéphane; Normand, Anne-Cécile; Fourquet, Patrick; Thiebault, Sandrine; Planard, Chantal; Hendrickx, Marijke; Piarroux, Renaud

    2011-01-01

    MALDI-TOF MS recently emerged as a valuable identification tool for bacteria and yeasts and revolutionized the daily clinical laboratory routine. But it has not been established for routine mould identification. This study aimed to validate a standardized procedure for MALDI-TOF MS-based mould identification in clinical laboratory. First, pre-extraction and extraction procedures were optimized. With this standardized procedure, a 143 mould strains reference spectra library was built. Then, the mould isolates cultured from sequential clinical samples were prospectively subjected to this MALDI-TOF MS based-identification assay. MALDI-TOF MS-based identification was considered correct if it was concordant with the phenotypic identification; otherwise, the gold standard was DNA sequence comparison-based identification. The optimized procedure comprised a culture on sabouraud-gentamicin-chloramphenicol agar followed by a chemical extraction of the fungal colonies with formic acid and acetonitril. The identification was done using a reference database built with references from at least four culture replicates. For five months, 197 clinical isolates were analyzed; 20 were excluded because they were not identified at the species level. MALDI-TOF MS-based approach correctly identified 87% (154/177) of the isolates analyzed in a routine clinical laboratory activity. It failed in 12% (21/177), whose species were not represented in the reference library. MALDI-TOF MS-based identification was correct in 154 out of the remaining 156 isolates. One Beauveria bassiana was not identified and one Rhizopus oryzae was misidentified as Mucor circinelloides. This work's seminal finding is that a standardized procedure can also be used for MALDI-TOF MS-based identification of a wide array of clinically relevant mould species. It thus makes it possible to identify moulds in the routine clinical laboratory setting and opens new avenues for the development of an integrated MALDI-TOF MS-based solution for the identification of any clinically relevant microorganism.

  13. Genomes OnLine Database (GOLD) v.6: data updates and feature enhancements

    PubMed Central

    Mukherjee, Supratim; Stamatis, Dimitri; Bertsch, Jon; Ovchinnikova, Galina; Verezemska, Olena; Isbandi, Michelle; Thomas, Alex D.; Ali, Rida; Sharma, Kaushal; Kyrpides, Nikos C.; Reddy, T. B. K.

    2017-01-01

    The Genomes Online Database (GOLD) (https://gold.jgi.doe.gov) is a manually curated data management system that catalogs sequencing projects with associated metadata from around the world. In the current version of GOLD (v.6), all projects are organized based on a four level classification system in the form of a Study, Organism (for isolates) or Biosample (for environmental samples), Sequencing Project and Analysis Project. Currently, GOLD provides information for 26 117 Studies, 239 100 Organisms, 15 887 Biosamples, 97 212 Sequencing Projects and 78 579 Analysis Projects. These are integrated with over 312 metadata fields from which 58 are controlled vocabularies with 2067 terms. The web interface facilitates submission of a diverse range of Sequencing Projects (such as isolate genome, single-cell genome, metagenome, metatranscriptome) and complex Analysis Projects (such as genome from metagenome, or combined assembly from multiple Sequencing Projects). GOLD provides a seamless interface with the Integrated Microbial Genomes (IMG) system and supports and promotes the Genomic Standards Consortium (GSC) Minimum Information standards. This paper describes the data updates and additional features added during the last two years. PMID:27794040

  14. The Genomes OnLine Database (GOLD) v.5: a metadata management system based on a four level (meta)genome project classification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reddy, Tatiparthi B. K.; Thomas, Alex D.; Stamatis, Dimitri

    The Genomes OnLine Database (GOLD; http://www.genomesonline.org) is a comprehensive online resource to catalog and monitor genetic studies worldwide. GOLD provides up-to-date status on complete and ongoing sequencing projects along with a broad array of curated metadata. Within this paper, we report version 5 (v.5) of the database. The newly designed database schema and web user interface supports several new features including the implementation of a four level (meta)genome project classification system and a simplified intuitive web interface to access reports and launch search tools. The database currently hosts information for about 19 200 studies, 56 000 Biosamples, 56 000 sequencingmore » projects and 39 400 analysis projects. More than just a catalog of worldwide genome projects, GOLD is a manually curated, quality-controlled metadata warehouse. The problems encountered in integrating disparate and varying quality data into GOLD are briefly highlighted. Lastly, GOLD fully supports and follows the Genomic Standards Consortium (GSC) Minimum Information standards.« less

  15. The accuracy of ultrashort echo time MRI sequences for medical additive manufacturing

    PubMed Central

    Rijkhorst, Erik-Jan; Hofman, Mark; Forouzanfar, Tymour; Wolff, Jan

    2016-01-01

    Objectives: Additively manufactured bone models, implants and drill guides are becoming increasingly popular amongst maxillofacial surgeons and dentists. To date, such constructs are commonly manufactured using CT technology that induces ionizing radiation. Recently, ultrashort echo time (UTE) MRI sequences have been developed that allow radiation-free imaging of facial bones. The aim of the present study was to assess the feasibility of UTE MRI sequences for medical additive manufacturing (AM). Methods: Three morphologically different dry human mandibles were scanned using a CT and MRI scanner. Additionally, optical scans of all three mandibles were made to acquire a “gold standard”. All CT and MRI scans were converted into Standard Tessellation Language (STL) models and geometrically compared with the gold standard. To quantify the accuracy of the AM process, the CT, MRI and gold-standard STL models of one of the mandibles were additively manufactured, optically scanned and compared with the original gold-standard STL model. Results: Geometric differences between all three CT-derived STL models and the gold standard were <1.0 mm. All three MRI-derived STL models generally presented deviations <1.5 mm in the symphyseal and mandibular area. The AM process introduced minor deviations of <0.5 mm. Conclusions: This study demonstrates that MRI using UTE sequences is a feasible alternative to CT in generating STL models of the mandible and would therefore be suitable for surgical planning and AM. Further in vivo studies are necessary to assess the usability of UTE MRI sequences in clinical settings. PMID:26943179

  16. Relevance similarity: an alternative means to monitor information retrieval systems

    PubMed Central

    Dong, Peng; Loh, Marie; Mondry, Adrian

    2005-01-01

    Background Relevance assessment is a major problem in the evaluation of information retrieval systems. The work presented here introduces a new parameter, "Relevance Similarity", for the measurement of the variation of relevance assessment. In a situation where individual assessment can be compared with a gold standard, this parameter is used to study the effect of such variation on the performance of a medical information retrieval system. In such a setting, Relevance Similarity is the ratio of assessors who rank a given document same as the gold standard over the total number of assessors in the group. Methods The study was carried out on a collection of Critically Appraised Topics (CATs). Twelve volunteers were divided into two groups of people according to their domain knowledge. They assessed the relevance of retrieved topics obtained by querying a meta-search engine with ten keywords related to medical science. Their assessments were compared to the gold standard assessment, and Relevance Similarities were calculated as the ratio of positive concordance with the gold standard for each topic. Results The similarity comparison among groups showed that a higher degree of agreements exists among evaluators with more subject knowledge. The performance of the retrieval system was not significantly different as a result of the variations in relevance assessment in this particular query set. Conclusion In assessment situations where evaluators can be compared to a gold standard, Relevance Similarity provides an alternative evaluation technique to the commonly used kappa scores, which may give paradoxically low scores in highly biased situations such as document repositories containing large quantities of relevant data. PMID:16029513

  17. Effects of disease severity distribution on the performance of quantitative diagnostic methods and proposal of a novel 'V-plot' methodology to display accuracy values.

    PubMed

    Petraco, Ricardo; Dehbi, Hakim-Moulay; Howard, James P; Shun-Shin, Matthew J; Sen, Sayan; Nijjer, Sukhjinder S; Mayet, Jamil; Davies, Justin E; Francis, Darrel P

    2018-01-01

    Diagnostic accuracy is widely accepted by researchers and clinicians as an optimal expression of a test's performance. The aim of this study was to evaluate the effects of disease severity distribution on values of diagnostic accuracy as well as propose a sample-independent methodology to calculate and display accuracy of diagnostic tests. We evaluated the diagnostic relationship between two hypothetical methods to measure serum cholesterol (Chol rapid and Chol gold ) by generating samples with statistical software and (1) keeping the numerical relationship between methods unchanged and (2) changing the distribution of cholesterol values. Metrics of categorical agreement were calculated (accuracy, sensitivity and specificity). Finally, a novel methodology to display and calculate accuracy values was presented (the V-plot of accuracies). No single value of diagnostic accuracy can be used to describe the relationship between tests, as accuracy is a metric heavily affected by the underlying sample distribution. Our novel proposed methodology, the V-plot of accuracies, can be used as a sample-independent measure of a test performance against a reference gold standard.

  18. [Who Hits the Mark? A Comparative Study of the Free Geocoding Services of Google and OpenStreetMap].

    PubMed

    Lemke, D; Mattauch, V; Heidinger, O; Hense, H W

    2015-09-01

    Geocoding, the process of converting textual information (addresses) into geographic coordinates is increasingly used in public health/epidemiological research and practice. To date, little attention has been paid to geocoding quality and its impact on different types of spatially-related health studies. The primary aim of this study was to compare 2 freely available geocoding services (Google and OpenStreetMap) with regard to matching rate (percentage of address records capable of being geocoded) and positional accuracy (distance between geocodes and the ground truth locations). Residential addresses were geocoded by the NRW state office for information and technology and were considered as reference data (gold standard). The gold standard included the coordinates, the quality of the addresses (4 categories), and a binary urbanity indicator based on the CORINE land cover data. 2 500 addresses were randomly sampled after stratification for address quality and urbanity indicator (approximately 20 000 addresses). These address samples were geocoded using the geocoding services from Google and OSM. In general, both geocoding services showed a decrease in the matching rate with decreasing address quality and urbanity. Google showed consistently a higher completeness than OSM (>93 vs. >82%). Also, the cartographic confounding between urban and rural regions was less distinct with Google's geocoding API. Regarding the positional accuracy of the geo-coordinates, Google also showed the smallest deviations from the reference coordinates, with a median of <9 vs. <175.8 m. The cumulative density function derived from the positional accuracy showed for Google that nearly 95% and for OSM 50% of the addresses were geocoded within <50 m of their reference coordinates. The geocoding API from Google is superior to OSM regarding completeness and positional accuracy of the geocoded addresses. On the other hand, Google has several restrictions, such as the limitation of the requests to 2 500 addresses per 24 h and the presentation of the results exclusively on Google Maps, which may complicate the use for scientific purposes. © Georg Thieme Verlag KG Stuttgart · New York.

  19. Grading School Choice: Evaluating School Choice Programs by the Friedman Gold Standard. School Choice Issues in Depth

    ERIC Educational Resources Information Center

    Enlow, Robert C.

    2008-01-01

    In 2004, The Friedman Foundation for Educational Choice published a report titled "Grading Vouchers: Ranking America's School Choice Programs." Its purpose was to measure every existing school choice program against the gold standard set by Milton and Rose Friedman: that the most effective way to improve K-12 education and thus ensure a stable…

  20. Ultrasound functional evaluation of fetuses with myelomeningocele: study of the interpretation of results.

    PubMed

    Maroto, A; Illescas, T; Meléndez, M; Arévalo, S; Rodó, C; Peiró, J L; Belfort, M; Cuxart, A; Carreras, E

    2017-10-01

    To assess the reliability of the interpretation of a new technique for the ultrasound evaluation of the level of neurological lesion in fetuses with myelomeningocele. Observational study including myelomeningocele fetuses, referred to our center for the sonographic assessment of the fetal lower-limb movements, made and recorded by an expert in Maternal-fetal medicine and a specialist in Rehabilitation. Two observers, with different levels of expertise and blinded to each other's results, interpreted each recorded scan two different times. The agreement for the segmental levels assigned between the observers and the gold standard, the inter-observer and intra-observer reproducibility were tested using the weighed Kappa (wκ) index. Twenty-eight scans were recorded and evaluated. The agreement between the observers and the gold standard remained constant for the expert observer (wκ = 0.82) and increased (wκ = 0.66-wκ = 0.72) for the other one. The inter-observer and the intra-observer variability for the expert observer were wκ = 0.72 and wκ = 0.94, respectively. The agreement for the prenatal evaluation of the segmental neurological level was excellent, after a short training period, for observers with different degrees of expertise. The interpretation of this technique is reproducible enough and this supports its value for the prediction of postnatal motor function in myelomeningocele fetuses.

  1. A new responder criterion (relative effect per patient (REPP) > 0.2) externally validated in a large total hip replacement multicenter cohort (EUROHIP).

    PubMed

    Huber, J; Hüsler, J; Dieppe, P; Günther, K P; Dreinhöfer, K; Judge, A

    2016-03-01

    To validate a new method to identify responders (relative effect per patient (REPP) >0.2) using the OMERACT-OARSI criteria as gold standard in a large multicentre sample. The REPP ([score before - after treatment]/score before treatment) was calculated for 845 patients of a large multicenter European cohort study for THR. The patients with a REPP >0.2 were defined as responders. The responder rate was compared to the gold standard (OMERACT-OARSI criteria) using receiver operator characteristic (ROC) curve analysis for sensitivity, specificity and percentage of appropriately classified patients. With the criterion REPP>0.2 85.4% of the patients were classified as responders, applying the OARSI-OMERACT criteria 85.7%. The new method had 98.8% sensitivity, 94.2% specificity and 98.1% of the patients were correctly classified compared to the gold standard. The external validation showed a high sensitivity and also specificity of a new criterion to identify a responder compared to the gold standard method. It is simple and has no uncertainties due to a single classification criterion. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  2. Short communication: Evaluation of MALDI-TOF mass spectrometry and a custom reference spectra expanded database for the identification of bovine-associated coagulase-negative staphylococci.

    PubMed

    Cameron, M; Perry, J; Middleton, J R; Chaffer, M; Lewis, J; Keefe, G P

    2018-01-01

    This study evaluated MALDI-TOF mass spectrometry and a custom reference spectra expanded database for the identification of bovine-associated coagulase-negative staphylococci (CNS). A total of 861 CNS isolates were used in the study, covering 21 different CNS species. The majority of the isolates were previously identified by rpoB gene sequencing (n = 804) and the remainder were identified by sequencing of hsp60 (n = 56) and tuf (n = 1). The genotypic identification was considered the gold standard identification. Using a direct transfer protocol and the existing commercial database, MALDI-TOF mass spectrometry showed a typeability of 96.5% (831/861) and an accuracy of 99.2% (824/831). Using a custom reference spectra expanded database, which included an additional 13 in-house created reference spectra, isolates were identified by MALDI-TOF mass spectrometry with 99.2% (854/861) typeability and 99.4% (849/854) accuracy. Overall, MALDI-TOF mass spectrometry using the direct transfer method was shown to be a highly reliable tool for the identification of bovine-associated CNS. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  3. Arsenic and mercury concentrations in marine fish sourced from local fishermen and fish markets in mine-impacted communities in Ratatotok Sub-district, North Sulawesi, Indonesia.

    PubMed

    Bentley, Keith; Soebandrio, Amin

    2017-07-15

    Mesel gold mine, Ratatotok Sub-district, North Sulawesi, Indonesia deposited about 4.5millionm 3 of detoxified tailings containing arsenic (As) and mercury (Hg) via a submarine pipeline into Buyat Bay. As and Hg analysis of 216 fish muscle tissue composites from subsistence fishermen, local markets and a reference market confirmed that mean As levels were comparable between locations (range 1.71 to 2.12mg/kg wet weight (ww)) and <10% of the Australia New Zealand standard. Mean Hg concentrations were highest for the artisanal fishermen group (0.23mg/kg ww), similar between the local markets (0.11-0.14mg/kg ww) and lower at the reference market (0.04mg/kg ww). A 12-month fish availability study identified that the results were due to the different coral and deep ocean species assemblages. All mean values were <50% of the FAO/WHO/Codex standard for Hg. The results confirmed that there was no contamination from the deposited submarine tailings. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  4. Comparison of four different techniques to evaluate the elastic properties of phantom in elastography: is there a gold standard?

    NASA Astrophysics Data System (ADS)

    Oudry, Jennifer; Lynch, Ted; Vappou, Jonathan; Sandrin, Laurent; Miette, Véronique

    2014-10-01

    Elastographic techniques used in addition to imaging techniques (ultrasound, resonance magnetic or optical) provide new clinical information on the pathological state of soft tissues. However, system-dependent variation in elastographic measurements may limit the clinical utility of these measurements by introducing uncertainty into the measurement. This work is aimed at showing differences in the evaluation of the elastic properties of phantoms performed by four different techniques: quasi-static compression, dynamic mechanical analysis, vibration-controlled transient elastography and hyper-frequency viscoelastic spectroscopy. Four Zerdine® gel materials were tested and formulated to yield a Young’s modulus over the range of normal and cirrhotic liver stiffnesses. The Young’s modulus and the shear wave speed obtained with each technique were compared. Results suggest a bias in elastic property measurement which varies with systems and highlight the difficulty in finding a reference method to determine and assess the elastic properties of tissue-mimicking materials. Additional studies are needed to determine the source of this variation, and control for them so that accurate, reproducible reference standards can be made for the absolute measurement of soft tissue elasticity.

  5. Comparison of four different techniques to evaluate the elastic properties of phantom in elastography: is there a gold standard?

    PubMed

    Oudry, Jennifer; Lynch, Ted; Vappou, Jonathan; Sandrin, Laurent; Miette, Véronique

    2014-10-07

    Elastographic techniques used in addition to imaging techniques (ultrasound, resonance magnetic or optical) provide new clinical information on the pathological state of soft tissues. However, system-dependent variation in elastographic measurements may limit the clinical utility of these measurements by introducing uncertainty into the measurement. This work is aimed at showing differences in the evaluation of the elastic properties of phantoms performed by four different techniques: quasi-static compression, dynamic mechanical analysis, vibration-controlled transient elastography and hyper-frequency viscoelastic spectroscopy. Four Zerdine® gel materials were tested and formulated to yield a Young's modulus over the range of normal and cirrhotic liver stiffnesses. The Young's modulus and the shear wave speed obtained with each technique were compared. Results suggest a bias in elastic property measurement which varies with systems and highlight the difficulty in finding a reference method to determine and assess the elastic properties of tissue-mimicking materials. Additional studies are needed to determine the source of this variation, and control for them so that accurate, reproducible reference standards can be made for the absolute measurement of soft tissue elasticity.

  6. The Quantitative Science of Evaluating Imaging Evidence.

    PubMed

    Genders, Tessa S S; Ferket, Bart S; Hunink, M G Myriam

    2017-03-01

    Cardiovascular diagnostic imaging tests are increasingly used in everyday clinical practice, but are often imperfect, just like any other diagnostic test. The performance of a cardiovascular diagnostic imaging test is usually expressed in terms of sensitivity and specificity compared with the reference standard (gold standard) for diagnosing the disease. However, evidence-based application of a diagnostic test also requires knowledge about the pre-test probability of disease, the benefit of making a correct diagnosis, the harm caused by false-positive imaging test results, and potential adverse effects of performing the test itself. To assist in clinical decision making regarding appropriate use of cardiovascular diagnostic imaging tests, we reviewed quantitative concepts related to diagnostic performance (e.g., sensitivity, specificity, predictive values, likelihood ratios), as well as possible biases and solutions in diagnostic performance studies, Bayesian principles, and the threshold approach to decision making. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  7. Toward a New Gold Standard for Early Safety: Automated Temperature-Controlled hERG Test on the PatchLiner®

    PubMed Central

    Polonchuk, Liudmila

    2012-01-01

    The Patchliner® temperature-controlled automated patch clamp system was evaluated for testing drug effects on potassium currents through human ether-à-go-go related gene (hERG) channels expressed in Chinese hamster ovary cells at 35–37°C. IC50 values for a set of reference drugs were compared with those obtained using the conventional voltage clamp technique. The results showed good correlation between the data obtained using automated and conventional electrophysiology. Based on these results, the Patchliner® represents an innovative automated electrophysiology platform for conducting the hERG assay that substantially increases throughput and has the advantage of operating at physiological temperature. It allows fast, accurate, and direct assessment of channel function to identify potential proarrhythmic side effects and sets a new standard in ion channel research for drug safety testing. PMID:22303293

  8. Spanish food composition tables and databases: need for a gold standard for healthcare professionals (review).

    PubMed

    Lupiañez-Barbero, Ascension; González Blanco, Cintia; de Leiva Hidalgo, Alberto

    2018-05-23

    Food composition tables and databases (FCTs or FCDBs) provide the necessary information to estimate intake of nutrients and other food components. In Spain, the lack of a reference database has resulted in use of different FCTs/FCDBs in nutritional surveys and research studies, as well as for development of dietetic for diet analysis. As a result, biased, non-comparable results are obtained, and healthcare professionals are rarely aware of these limitations. AECOSAN and the BEDCA association developed a FCDB following European standards, the Spanish Food Composition Database Network (RedBEDCA).The current database has a limited number of foods and food components and barely contains processed foods, which limits its use in epidemiological studies and in the daily practice of healthcare professionals. Copyright © 2018 SEEN y SED. Publicado por Elsevier España, S.L.U. All rights reserved.

  9. 40 CFR 440.140 - Applicability; description of the gold placer mine subcategory.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS (CONTINUED) ORE MINING AND DRESSING POINT SOURCE... that produce gold or gold bearing ores from placer deposits; and (2) The beneficiation processes which... yards (cu yd) of ore per year, or to dredges which process less than 50,000 cu yd of ore per year, or to...

  10. 40 CFR 440.140 - Applicability; description of the gold placer mine subcategory.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS (CONTINUED) ORE MINING AND DRESSING POINT SOURCE... that produce gold or gold bearing ores from placer deposits; and (2) The beneficiation processes which... yards (cu yd) of ore per year, or to dredges which process less than 50,000 cu yd of ore per year, or to...

  11. 40 CFR 440.140 - Applicability; description of the gold placer mine subcategory.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS (CONTINUED) ORE MINING AND DRESSING POINT SOURCE... that produce gold or gold bearing ores from placer deposits; and (2) The beneficiation processes which... yards (cu yd) of ore per year, or to dredges which process less than 50,000 cu yd of ore per year, or to...

  12. Microwave-assisted synthesis of water-soluble, fluorescent gold nanoclusters capped with small organic molecules and a revealing fluorescence and X-ray absorption study

    NASA Astrophysics Data System (ADS)

    Helmbrecht, C.; Lützenkirchen-Hecht, D.; Frank, W.

    2015-03-01

    Colourless solutions of blue light-emitting, water-soluble gold nanoclusters (AuNC) were synthesized from gold colloids under microwave irradiation using small organic molecules as ligands. Stabilized by 1,3,5-triaza-7-phosphaadamantane (TPA) or l-glutamine (GLU), fluorescence quantum yields up to 5% were obtained. AuNC are considered to be very promising for biological labelling, optoelectronic devices and light-emitting materials but the structure-property relationships have still not been fully clarified. To expand the knowledge about the AuNC apart from their fluorescent properties they were studied by X-ray absorption spectroscopy elucidating the oxidation state of the nanoclusters' gold atoms. Based on curve fitting of the XANES spectra in comparison to several gold references, optically transparent fluorescent AuNC are predicted to be ligand-stabilized Au5+ species. Additionally, their near edge structure compared with analogous results of polynuclear clusters known from the literature discloses an increasing intensity of the feature close to the absorption edge with decreasing cluster size. As a result, a linear relationship between the cluster size and the X-ray absorption coefficient can be established for the first time.Colourless solutions of blue light-emitting, water-soluble gold nanoclusters (AuNC) were synthesized from gold colloids under microwave irradiation using small organic molecules as ligands. Stabilized by 1,3,5-triaza-7-phosphaadamantane (TPA) or l-glutamine (GLU), fluorescence quantum yields up to 5% were obtained. AuNC are considered to be very promising for biological labelling, optoelectronic devices and light-emitting materials but the structure-property relationships have still not been fully clarified. To expand the knowledge about the AuNC apart from their fluorescent properties they were studied by X-ray absorption spectroscopy elucidating the oxidation state of the nanoclusters' gold atoms. Based on curve fitting of the XANES spectra in comparison to several gold references, optically transparent fluorescent AuNC are predicted to be ligand-stabilized Au5+ species. Additionally, their near edge structure compared with analogous results of polynuclear clusters known from the literature discloses an increasing intensity of the feature close to the absorption edge with decreasing cluster size. As a result, a linear relationship between the cluster size and the X-ray absorption coefficient can be established for the first time. Electronic supplementary information (ESI) available: The deconvoluted reference spectra are given in ESI Fig. 1-9. See DOI: 10.1039/c4nr07051h

  13. NCI Updates Tobacco Policies Following Re-accreditation | Poster

    Cancer.gov

    This year, NCI was re-accredited as one of nearly 200 CEO Cancer Gold Standard employers across the United States. According to its website, “the CEO Cancer Gold Standard provides a framework for employers to have a healthier workplace by focusing on cancer risk reduction, early detection, and access to clinical trials and high-quality care.” As part of this re-accreditation,

  14. SU-F-T-617: Remotely Pre-Planned Stereotactic Ablative Radiation Therapy: Validation of Treatment Plan Quality

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Juang, T; Bush, K; Loo, B

    Purpose: We propose a workflow to improve access to stereotactic ablative radiation therapy (SABR) for rural patients. When implemented, a separate trip to the central facility for simulation can be eliminated. Two elements are required: (1) Fabrication of custom immobilization devices to match positioning on prior diagnostic CT (dxCT). (2) Remote radiation pre-planning on dxCT, with transfer of contours/plan to simulation CT (simCT) and initiation of treatment same-day or next day. In this retrospective study, we validated part 2 of the workflow using patients already treated with SABR for upper lobe lung tumors. Methods: Target/normal structures were contoured on dxCT;more » a plan was created and approved by the physician. Structures were transferred to simCT using deformable image registration and the plan was re-optimized on simCT. Plan quality was evaluated through comparison to gold-standard structures contoured on simCT and a gold-standard plan based on these structures. Workflow-generated plan quality in this study represents a worst-case scenario as these patients were not treated using custom immobilization to match dxCT position as would be done when the workflow is implemented clinically. Results: 5/6 plans created through the pre-planning workflow were clinically acceptable. For all six plans, the gold-standard GTV received full prescription dose, along with median PTV V95%=95.2% and median PTV D95%=95.4%. Median GTV DSC=0.80, indicating high degree of similarity between the deformed and gold-standard GTV contours despite small GTV sizes (mean=3.0cc). One outlier (DSC=0.49) resulted in inadequate PTV coverage (V95%=62.9%) in the workflow plan; in clinical practice, this mismatch between deformed/gold-standard GTV would be revised by the physician after deformable registration. For all patients, normal tissue doses were comparable to the gold-standard plan and well within constraints. Conclusion: Pre-planning SABR cases on diagnostic imaging generated clinically acceptable plans. Coupled with rapid-prototyped custom immobilization, this workflow may improve treatment access for rural patients.« less

  15. Multi-technique characterization of gold electroplating on silver substrates for cultural heritage applications

    NASA Astrophysics Data System (ADS)

    Ortega-Feliu, I.; Ager, F. J.; Roldán, C.; Ferretti, M.; Juanes, D.; Scrivano, S.; Respaldiza, M. A.; Ferrazza, L.; Traver, I.; Grilli, M. L.

    2017-09-01

    This work presents a detailed study of a series of silver plates gilded via electroplating techniques in which the characteristics of the coating gold layers are investigated as a function of the electroplating variables (voltage, time, anode surface and temperature). Some reference samples were coated by radio frequency sputtering in order to compare gold layer homogeneity and effective density. Surface analysis was performed by means of atomic and nuclear techniques (SEM-EDX, EDXRF, PIXE and RBS) to obtain information about thickness, homogeneity, effective density, profile concentration of the gold layers and Au-Ag diffusion profiles. The gold layer thickness obtained by PIXE and EDXRF is consistent with the thickness obtained by means of RBS depth profiling. Electroplated gold mass thickness increases with electroplating time, anode area and voltage. However, electrodeposited samples present rough interfaces and gold layer effective densities lower than the nominal density of Au (19.3 g/cm3), whereas sputtering produces uniform layers with nominal density. These analyses provide valuable information to historians and curators and can help the restoration process of gold-plated silver objects.

  16. Reduced Expiratory Flow Rate among Heavy Smokers Increases Lung Cancer Risk. Results from the National Lung Screening Trial-American College of Radiology Imaging Network Cohort.

    PubMed

    Hopkins, Raewyn J; Duan, Fenghai; Chiles, Caroline; Greco, Erin M; Gamble, Greg D; Aberle, Denise; Young, Robert P

    2017-03-01

    Although epidemiological studies consistently show that chronic obstructive pulmonary disease is associated with an increased risk of lung cancer, debate exists as to whether there is a linear relationship between the severity of airflow limitation and lung cancer risk. We examined this in a large, prospective study of older heavy smokers from the American College of Radiology Imaging Network subcohort of the National Lung Screening Trial (ACRIN). Airflow limitation was defined by prebronchodilator spirometry subgrouped according to Global Initiative for Chronic Obstructive Lung Disease (GOLD) grades 1-4. In the National Lung Screening Trial-ACRIN cohort of 18,473 screening participants, 6,436 had airflow limitation (35%) and 12,037 (65%) had no airflow limitation. From these groups, 758 lung cancer cases were prospectively identified. Participants with airflow limitation were stratified according to GOLD groups 1 (n = 1,607), 2 (n = 3,528), 3 (n = 1,083), and 4 (n = 211). Lung cancer incidence at study end (mean follow-up, 6.4 yr) was compared between the GOLD groups and those with no airflow limitation (referent group). Compared with those with no airflow limitation, where lung cancer incidence was 3.78/1,000 person years, incidence rates increased in a simple linear relationship: GOLD 1 (6.27/1,000 person yr); GOLD 2 (7.86/1,000 person yr); GOLD 3 (10.71/1,000 person yr); and GOLD 4 (13.25/1,000 person yr). All relationships were significant versus the reference group at a P value of 0.0001 or less. In a large prospective study of high-risk cigarette smokers, we report a strong linear relationship between increasing severity of airflow limitation and risk of lung cancer.

  17. Seeking a valid gold standard for an innovative, dialect-neutral language test.

    PubMed

    Pearson, Barbara Zurer; Jackson, Janice E; Wu, Haotian

    2014-04-01

    PURPOSE In this study, the authors explored alternative gold standards to validate an innovative, dialect-neutral language assessment. METHOD Participants were 78 African American children, ages 5;0 (years;months) to 6;11. Twenty participants had previously been identified as having language impairment. The Diagnostic Evaluation of Language Variation-Norm Referenced (DELV-NR; Seymour, Roeper, & J. de Villiers, 2005) was administered, and concurrent language samples (LSs) were collected. Using LS profiles as the gold standard, sensitivity, specificity, and other measures of diagnostic accuracy were compared for diagnoses made from the DELV-NR and participants' clinical status prior to recruitment. In a second analysis, the authors used results from the first analysis to make evidence-based adjustments in the estimates of DELV-NR diagnostic accuracy. RESULTS Accuracy of the DELV-NR relative to LS profiles was greater than that of prior diagnoses, indicating that the DELV-NR was an improvement over preexisting diagnoses for this group. Specificity met conventional standards, but sensitivity was somewhat low. Reanalysis using the positive and negative predictive power of the preexisting diagnosis in a discrepant-resolution procedure revealed that estimates for sensitivity and specificity for the DELV-NR were .85 and .93, respectively. CONCLUSION The authors found that, even after making allowances for the imperfection of available gold standards, clinical decisions made with the DELV-NR achieved high values on conventional measures of diagnostic accuracy.

  18. FEV1/FVC and FEV1 for the assessment of chronic airflow obstruction in prevalence studies: do prediction equations need revision?

    PubMed

    Roche, Nicolas; Dalmay, François; Perez, Thierry; Kuntz, Claude; Vergnenègre, Alain; Neukirch, Françoise; Giordanella, Jean-Pierre; Huchon, Gérard

    2008-11-01

    Little is known on the long-term validity of reference equations used in the calculation of FEV(1) and FEV(1)/FVC predicted values. This survey assessed the prevalence of chronic airflow obstruction in a population-based sample and how it is influenced by: (i) the definition of airflow obstruction; and (ii) equations used to calculate predicted values. Subjects aged 45 or more were recruited in health prevention centers, performed spirometry and fulfilled a standardized ECRHS-derived questionnaire. Previously diagnosed cases and risk factors were identified. Prevalence of airflow obstruction was calculated using: (i) ATS-GOLD definition (FEV(1)/FVC<0.70); and (ii) ERS definition (FEV(1)/FVC

  19. A consensus-based gold standard for the evaluation of mass casualty triage systems.

    PubMed

    Lerner, E Brooke; McKee, Courtney H; Cady, Charles E; Cone, David C; Colella, M Riccardo; Cooper, Arthur; Coule, Phillip L; Lairet, Julio R; Liu, J Marc; Pirrallo, Ronald G; Sasser, Scott M; Schwartz, Richard; Shepherd, Greene; Swienton, Raymond E

    2015-01-01

    Accuracy and effectiveness analyses of mass casualty triage systems are limited because there are no gold standard definitions for each of the triage categories. Until there is agreement on which patients should be identified by each triage category, it will be impossible to calculate sensitivity and specificity or to compare accuracy between triage systems. To develop a consensus-based, functional gold standard definition for each mass casualty triage category. National experts were recruited through the lead investigators' contacts and their suggested contacts. Key informant interviews were conducted to develop a list of potential criteria for defining each triage category. Panelists were interviewed in order of their availability until redundancy of themes was achieved. Panelists were blinded to each other's responses during the interviews. A modified Delphi survey was developed with the potential criteria identified during the interview and delivered to all recruited experts. In the early rounds, panelists could add, remove, or modify criteria. In the final rounds edits were made to the criteria until at least 80% agreement was achieved. Thirteen national and local experts were recruited to participate in the project. Six interviews were conducted. Three rounds of voting were performed, with 12 panelists participating in the first round, 12 in the second round, and 13 in the third round. After the first two rounds, the criteria were modified according to respondent suggestions. In the final round, over 90% agreement was achieved for all but one criterion. A single e-mail vote was conducted on edits to the final criterion and consensus was achieved. A consensus-based, functional gold standard definition for each mass casualty triage category was developed. These gold standard definitions can be used to evaluate the accuracy of mass casualty triage systems after an actual incident, during training, or for research.

  20. Computed tomographic anatomy of the heads of blue-and-gold macaws (Ara ararauna), African grey parrots (Psittacus erithacus), and monk parakeets (Myiopsitta monachus).

    PubMed

    Veladiano, Irene A; Banzato, Tommaso; Bellini, Luca; Montani, Alessandro; Catania, Salvatore; Zotti, Alessandro

    2016-12-01

    OBJECTIVE To create an atlas of the normal CT anatomy of the head of blue-and-gold macaws (Ara ararauna), African grey parrots (Psittacus erithacus), and monk parakeets (Myiopsitta monachus). ANIMALS 3 blue-and-gold macaws, 5 African grey parrots, and 6 monk parakeets and cadavers of 4 adult blue-and-gold macaws, 4 adult African grey parrots, and 7 monk parakeets. PROCEDURES Contrast-enhanced CT imaging of the head of the live birds was performed with a 4-multidetector-row CT scanner. Cadaveric specimens were stored at -20°C until completely frozen, and each head was then sliced at 5-mm intervals to create reference cross sections. Frozen cross sections were cleaned with water and photographed on both sides. Anatomic structures within each head were identified with the aid of the available literature, labeled first on anatomic photographs, and then matched to and labeled on corresponding CT images. The best CT reconstruction filter, window width, and window level for obtaining diagnostic images of each structure were also identified. RESULTS Most of the clinically relevant structures of the head were identified in both the cross-sectional photographs and corresponding CT images. Optimal visibility of the bony structures was achieved via CT with a standard soft tissue filter and pulmonary window. The use of contrast medium allowed a thorough evaluation of the soft tissues. CONCLUSIONS AND CLINICAL RELEVANCE The labeled CT images and photographs of anatomic structures of the heads of common pet parrot species created in this study may be useful as an atlas to aid interpretation of images obtained with any imaging modality.

  1. National Accreditation and Its Role in Early Education: An Analysis of Florida's Gold Seal Quality Child-Care Program and Licensing Standards

    ERIC Educational Resources Information Center

    Winterbottom, Christian; Jones, Ithel

    2014-01-01

    This article reports on the first Florida statewide assessment of the Gold Seal Quality Care program, accreditation, and the relationship with licensing violations. This study analyzed the differences between the Department of Children and Families Gold Seal-Accredited facilities and nonaccredited facilities by comparing the facilities and the…

  2. Huckleberry Gold: A high antioxidant purple skin-yellow flesh specialty market cultivar with potato cyst nematode resistance (H1) and potato virus X resistance (Nb and Rx1)

    USDA-ARS?s Scientific Manuscript database

    Huckleberry Gold is a purple skinned, yellow fleshed fresh market cultivar with similar culinary qualities to the market standard Yukon Gold. It has lower specific gravity, sucrose and vitamin C content, but a significantly higher level of antioxidants. Notable disease resistant characteristics are ...

  3. Artisanal and Small-Scale Gold Mining Without Mercury

    EPA Pesticide Factsheets

    Mercury-free techniques are safer for miners, their families and local communities. They can also help miners qualify for certification under fair-mined standards, potentially allowing them to market their gold at higher prices.

  4. Twenty years after Erich Muhe: Persisting controversies with the gold standard of laparoscopic cholecystectomy.

    PubMed

    Jani, Kalpesh; Rajan, P S; Sendhilkumar, K; Palanivelu, C

    2006-06-01

    This review article is a tribute to the genius of Professor Erich Muhe, a man ahead of his times. We trace the development of laparoscopic cholecystectomy and detail the tribulations faced by Muhe. On the occasion of the twentieth anniversary of the first laparoscopic cholecystectomy, we take another look at some of the controversies surrounding this gold standard in the management of gallbladder disease.

  5. An absolute cavity pyrgeometer to measure the absolute outdoor longwave irradiance with traceability to international system of units, SI

    NASA Astrophysics Data System (ADS)

    Reda, Ibrahim; Zeng, Jinan; Scheuch, Jonathan; Hanssen, Leonard; Wilthan, Boris; Myers, Daryl; Stoffel, Tom

    2012-03-01

    This article describes a method of measuring the absolute outdoor longwave irradiance using an absolute cavity pyrgeometer (ACP), U.S. Patent application no. 13/049, 275. The ACP consists of domeless thermopile pyrgeometer, gold-plated concentrator, temperature controller, and data acquisition. The dome was removed from the pyrgeometer to remove errors associated with dome transmittance and the dome correction factor. To avoid thermal convection and wind effect errors resulting from using a domeless thermopile, the gold-plated concentrator was placed above the thermopile. The concentrator is a dual compound parabolic concentrator (CPC) with 180° view angle to measure the outdoor incoming longwave irradiance from the atmosphere. The incoming irradiance is reflected from the specular gold surface of the CPC and concentrated on the 11 mm diameter of the pyrgeometer's blackened thermopile. The CPC's interior surface design and the resulting cavitation result in a throughput value that was characterized by the National Institute of Standards and Technology. The ACP was installed horizontally outdoor on an aluminum plate connected to the temperature controller to control the pyrgeometer's case temperature. The responsivity of the pyrgeometer's thermopile detector was determined by lowering the case temperature and calculating the rate of change of the thermopile output voltage versus the changing net irradiance. The responsivity is then used to calculate the absolute atmospheric longwave irradiance with an uncertainty estimate (U95) of ±3.96 W m-2 with traceability to the International System of Units, SI. The measured irradiance was compared with the irradiance measured by two pyrgeometers calibrated by the World Radiation Center with traceability to the Interim World Infrared Standard Group, WISG. A total of 408 readings were collected over three different nights. The calculated irradiance measured by the ACP was 1.5 W/m2 lower than that measured by the two pyrgeometers that are traceable to WISG, with a standard deviation of ±0.7 W m-2. These results suggest that the ACP design might be used for addressing the need to improve the international reference for broadband outdoor longwave irradiance measurements.

  6. Building an Evaluation Scale using Item Response Theory.

    PubMed

    Lalor, John P; Wu, Hao; Yu, Hong

    2016-11-01

    Evaluation of NLP methods requires testing against a previously vetted gold-standard test set and reporting standard metrics (accuracy/precision/recall/F1). The current assumption is that all items in a given test set are equal with regards to difficulty and discriminating power. We propose Item Response Theory (IRT) from psychometrics as an alternative means for gold-standard test-set generation and NLP system evaluation. IRT is able to describe characteristics of individual items - their difficulty and discriminating power - and can account for these characteristics in its estimation of human intelligence or ability for an NLP task. In this paper, we demonstrate IRT by generating a gold-standard test set for Recognizing Textual Entailment. By collecting a large number of human responses and fitting our IRT model, we show that our IRT model compares NLP systems with the performance in a human population and is able to provide more insight into system performance than standard evaluation metrics. We show that a high accuracy score does not always imply a high IRT score, which depends on the item characteristics and the response pattern.

  7. Building an Evaluation Scale using Item Response Theory

    PubMed Central

    Lalor, John P.; Wu, Hao; Yu, Hong

    2016-01-01

    Evaluation of NLP methods requires testing against a previously vetted gold-standard test set and reporting standard metrics (accuracy/precision/recall/F1). The current assumption is that all items in a given test set are equal with regards to difficulty and discriminating power. We propose Item Response Theory (IRT) from psychometrics as an alternative means for gold-standard test-set generation and NLP system evaluation. IRT is able to describe characteristics of individual items - their difficulty and discriminating power - and can account for these characteristics in its estimation of human intelligence or ability for an NLP task. In this paper, we demonstrate IRT by generating a gold-standard test set for Recognizing Textual Entailment. By collecting a large number of human responses and fitting our IRT model, we show that our IRT model compares NLP systems with the performance in a human population and is able to provide more insight into system performance than standard evaluation metrics. We show that a high accuracy score does not always imply a high IRT score, which depends on the item characteristics and the response pattern.1 PMID:28004039

  8. 76 FR 62891 - Self-Regulatory Organizations; Options Clearing Corporation; Notice of Filing of Proposed Rule...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-11

    ... relative total returns of a stock or exchange-traded fund (``ETF'') against another stock or ETF, including where one of the reference ETFs measured by the index is a gold- or silver-based ETF.\\3\\ Generally, a... of an underlying relative performance index is an ETF designed to measure the return of gold or...

  9. Comparison of Diagnostic Accuracy of Periprosthetic Tissue Culture in Blood Culture Bottles to That of Prosthesis Sonication Fluid Culture for Diagnosis of Prosthetic Joint Infection (PJI) by Use of Bayesian Latent Class Modeling and IDSA PJI Criteria for Classification.

    PubMed

    Yan, Qun; Karau, Melissa J; Greenwood-Quaintance, Kerryl E; Mandrekar, Jayawant N; Osmon, Douglas R; Abdel, Matthew P; Patel, Robin

    2018-06-01

    We have previously demonstrated that culturing periprosthetic tissue in blood culture bottles (BCBs) improves sensitivity compared to conventional agar and broth culture methods for diagnosis of prosthetic joint infection (PJI). We have also shown that prosthesis sonication culture improves sensitivity compared to periprosthetic tissue culture using conventional agar and broth methods. The purpose of this study was to compare the diagnostic accuracy of tissue culture in BCBs (subsequently referred to as tissue culture) to prosthesis sonication culture (subsequently referred to as sonicate fluid culture). We studied 229 subjects who underwent arthroplasty revision or resection surgery between March 2016 and October 2017 at Mayo Clinic in Rochester, Minnesota. Using the Infectious Diseases Society of America (IDSA) PJI diagnostic criteria (omitting culture criteria) as the gold standard, the sensitivity of tissue culture was similar to that of the sonicate fluid culture (66.4% versus 73.1%, P = 0.07) but was significantly lower than that of the two tests combined (66.4% versus 76.9%, P < 0.001). Using Bayesian latent class modeling, which assumes no gold standard for PJI diagnosis, the sensitivity of tissue culture was slightly lower than that of sonicate fluid culture (86.3% versus 88.7%) and much lower than that of the two tests combined (86.3% versus 99.1%). In conclusion, tissue culture in BCBs reached sensitivity similar to that of prosthesis sonicate fluid culture for diagnosis of PJI, but the two tests combined had the highest sensitivity without compromising specificity. The combination of tissue culture in BCBs and sonicate fluid culture is recommended to achieve the highest level of microbiological diagnosis of PJI. Copyright © 2018 American Society for Microbiology.

  10. Cardiac magnetic resonance radiofrequency tissue tagging for diagnosis of constrictive pericarditis: A proof of concept study.

    PubMed

    Power, John A; Thompson, Diane V; Rayarao, Geetha; Doyle, Mark; Biederman, Robert W W

    2016-05-01

    Invasive cardiac catheterization is the venerable "gold standard" for diagnosing constrictive pericarditis. However, its sensitivity and specificity vary dramatically from center to center. Given the ability to unequivocally define segments of the pericardium with the heart via radiofrequency tissue tagging, we hypothesize that cardiac magnetic resonance has the capability to be the new gold standard. All patients who were referred for cardiac magnetic resonance evaluation of constrictive pericarditis underwent cardiac magnetic resonance radiofrequency tissue tagging to define visceral-parietal pericardial adherence to determine constriction. This was then compared with intraoperative surgical findings. Likewise, all preoperative cardiac catheterization testing was reviewed in a blinded manner. A total of 120 patients were referred for clinical suspicion of constrictive pericarditis. Thirty-nine patients were defined as constrictive pericarditis positive solely via radiofrequency tissue-tagging cardiac magnetic resonance, of whom 21 were positive, 4 were negative, and 1 was equivocal for constrictive pericarditis, as defined by cardiac catheterization. Of these patients, 16 underwent pericardiectomy and were surgically confirmed. There was 100% agreement between cardiac magnetic resonance-defined constrictive pericarditis positivity and postsurgical findings. No patients were misclassified by cardiac magnetic resonance. In regard to the remaining constrictive pericarditis-positive patients defined by cardiac magnetic resonance, 10 were treated medically, declined, were ineligible for surgery, or were lost to follow-up. Long-term follow-up of those who were constrictive pericarditis negative by cardiac magnetic resonance showed no early or late crossover to the surgery arm. Cardiac magnetic resonance via radiofrequency tissue tagging offers a unique, efficient, and effective manner of defining clinically and surgically relevant constrictive pericarditis. Specifically, no patient who was identified with constriction via cardiac magnetic resonance underwent inappropriate sternotomy. However, catheterization had substantial and unacceptable false-positive and false-negative rates with important clinical ramifications. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  11. Fact Sheet - Final Air Toxics Rule for Gold Mine Ore Processing and Production

    EPA Pesticide Factsheets

    Fact sheet summarizing main points of National Emissions Standards for Hazardous Air Pollutants for gold ore processing and production facilities, the seventh largest source of mercury air emission in the United States.

  12. Immobilization of gold nanoparticles on cell culture surfaces for safe and enhanced gold nanoparticle-mediated laser transfection.

    PubMed

    Kalies, Stefan; Heinemann, Dag; Schomaker, Markus; Gentemann, Lara; Meyer, Heiko; Ripken, Tammo

    2014-01-01

    In comparison to standard transfection methods, gold nanoparticle-mediated laser transfection has proven to be a versatile alternative. This is based on its minor influence on cell viability and its high efficiency, especially for the delivery of small molecules like small interfering RNA. However, in order to transfer it to routine usage, a safety aspect is of major concern: The avoidance of nanoparticle uptake by the cells is desired. The immobilization of the gold nanoparticles on cell culture surfaces can address this issue. In this study, we achieved this by silanization of the appropriate surfaces and the binding of gold nanoparticles to them. Comparable perforation efficiencies to the previous approaches of gold nanoparticle-mediated laser transfection with free gold nanoparticles are demonstrated. The uptake of the immobilized particles by the cells is unlikely. Consequently, these investigations offer the possibility of bringing gold nanoparticle-mediated laser transfection closer to routine usage.

  13. Gold-coated copper cone detector as a new standard detector for F2 laser radiation at 157 nm.

    PubMed

    Kück, Stefan; Brandt, Friedhelm; Taddeo, Mario

    2005-04-20

    A new standard detector for high-accuracy measurements of F2 laser radiation at 157 nm is presented. This gold-coated copper cone detector permits the measurement of average powers up to 2 W with an uncertainty of approximately 1%. To the best of our knowledge, this is the first highly accurate standard detector for F2 laser radiation for this power level. It is fully characterized according to Guide to the Expression of Uncertainty in Measurement of the International Organization for Standardization and is connected to the calibration chain for laser radiation established by the German National Metrology Institute.

  14. 40 CFR 421.256 - Pretreatment standards for new sources.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Maximum for monthly average mg/troy ounce of gold and silver smelted Lead 0.364 0.169 Mercury 0.195 0.078 Silver 0.377 0.156 Zinc 1.326 0.546 Gold 0.130 (b) Silver chloride reduction spent solution. PSNS for the....024 Silver 0.116 0.048 Zinc 0.408 0.168 Gold 0.040 (c) Electrolytic cells wet air pollution control...

  15. 40 CFR 421.256 - Pretreatment standards for new sources.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Maximum for monthly average mg/troy ounce of gold and silver smelted Lead 0.364 0.169 Mercury 0.195 0.078 Silver 0.377 0.156 Zinc 1.326 0.546 Gold 0.130 (b) Silver chloride reduction spent solution. PSNS for the....024 Silver 0.116 0.048 Zinc 0.408 0.168 Gold 0.040 (c) Electrolytic cells wet air pollution control...

  16. 40 CFR 421.256 - Pretreatment standards for new sources.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Maximum for monthly average mg/troy ounce of gold and silver smelted Lead 0.364 0.169 Mercury 0.195 0.078 Silver 0.377 0.156 Zinc 1.326 0.546 Gold 0.130 (b) Silver chloride reduction spent solution. PSNS for the....024 Silver 0.116 0.048 Zinc 0.408 0.168 Gold 0.040 (c) Electrolytic cells wet air pollution control...

  17. Nonlinear optical response of a gold surface in the visible range: A study by two-color sum-frequency generation spectroscopy. I. Experimental determination

    NASA Astrophysics Data System (ADS)

    Dalstein, L.; Revel, A.; Humbert, C.; Busson, B.

    2018-04-01

    We experimentally determine the effective nonlinear second-order susceptibility of gold over the visible spectral range. To reach that goal, we probe by vibrational two-color sum-frequency generation spectroscopy the methyl stretching region of a dodecanethiol self-assembled monolayer adsorbed on a gold film. The sum-frequency generation spectra show a remarkable shape reversal when the visible probe wavelength is tuned from 435 to 705 nm. After correcting from Fresnel effects, the methyl stretching vibrations serve as an internal reference, allowing to extract the dispersion of the absolute phase and relative amplitude of the effective nonlinear optical response of gold in the visible range.

  18. Can We Create a "Gold Standard of Education" for Our Children through the "Advancement via Independent Determination (AVID) Program"?

    ERIC Educational Resources Information Center

    Gaskins, Darlene

    2014-01-01

    We need to come together as a team and become one system of total quality improvement regarding the education of our nation's children. In order to achieve a gold standard in the education of our nation's children, leadership has to be willing to go against the status quo and build bridges for long-term sustainable change. In order to survive,…

  19. Twenty years after Erich Muhe: Persisting controversies with the gold standard of laparoscopic cholecystectomy

    PubMed Central

    Jani, Kalpesh; Rajan, P S; Sendhilkumar, K; Palanivelu, C

    2006-01-01

    This review article is a tribute to the genius of Professor Erich Muhe, a man ahead of his times. We trace the development of laparoscopic cholecystectomy and detail the tribulations faced by Muhe. On the occasion of the twentieth anniversary of the first laparoscopic cholecystectomy, we take another look at some of the controversies surrounding this gold standard in the management of gallbladder disease PMID:21170235

  20. X-ray Fluorescence Spectroscopy Study of Coating Thickness and Base Metal Composition

    NASA Technical Reports Server (NTRS)

    Rolin, T. D.; Leszczuk, Y.

    2008-01-01

    For electrical, electronic, and electromechanical (EEE) parts to be approved for space use, they must be able to meet safety standards approved by NASA. A fast, reliable, and precise method is needed to make sure these standards are met. Many EEE parts are coated in gold (Au) and nickel (Ni), and the thickness coating is crucial to a part s performance. A nondestructive method that is efficient in measuring coating thickness is x-ray fluorescence (XRF) spectroscopy. The XRF spectrometer is a machine designed to measure layer thickness and composition of single or multilayered samples. By understanding the limitations in the collection of the data by this method, accurate composition and thickness measurements can be obtained for samples with Au and Ni coatings. To understand the limitations of data found, measurements were taken with the XRF spectrometer and compared to true values of standard reference materials (SRM) that were National Institute of Standards and Technology (NIST) traceable. For every sample, six different parameters were varied to understand measurement error: coating/substrate combination, number of layers, counting interval, collimator size, coating thickness, and test area location. Each measurement was taken in accordance with standards set by the American Society for Testing and Materials (ASTM) International Standard B 568.

  1. Throwing out the baby with the bathwater?: Comparing 2 approaches to implausible values of change in body size.

    PubMed

    Gray, Christine L; Robinson, Whitney R

    2014-07-01

    In childhood obesity research, the appearance of height loss, or "shrinkage," indicates measurement error. It is unclear whether a common response--excluding "shrinkers" from analysis--reduces bias. Using data from the National Longitudinal Study of Adolescent Health, we sampled 816 female adolescents (≥17 years) who had attained adult height by 1996 and for whom adult height was consistently measured in 2001 and 2008 ("gold-standard" height). We estimated adolescent obesity prevalence and the association of maternal education with adolescent obesity under 3 conditions: excluding shrinkers (for whom gold-standard height was less than recorded height in 1996), retaining shrinkers, and retaining shrinkers but substituting their gold-standard height. When we estimated obesity prevalence, excluding shrinkers decreased precision without improving validity. When we regressed obesity on maternal education, excluding shrinkers produced less valid and less precise estimates. In some circumstances, ignoring shrinkage is a better strategy than excluding shrinkers.

  2. Applying a statistical PTB detection procedure to complement the gold standard.

    PubMed

    Noor, Norliza Mohd; Yunus, Ashari; Bakar, S A R Abu; Hussin, Amran; Rijal, Omar Mohd

    2011-04-01

    This paper investigates a novel statistical discrimination procedure to detect PTB when the gold standard requirement is taken into consideration. Archived data were used to establish two groups of patients which are the control and test group. The control group was used to develop the statistical discrimination procedure using four vectors of wavelet coefficients as feature vectors for the detection of pulmonary tuberculosis (PTB), lung cancer (LC), and normal lung (NL). This discrimination procedure was investigated using the test group where the number of sputum positive and sputum negative cases that were correctly classified as PTB cases were noted. The proposed statistical discrimination method is able to detect PTB patients and LC with high true positive fraction. The method is also able to detect PTB patients that are sputum negative and therefore may be used as a complement to the gold standard. Copyright © 2010 Elsevier Ltd. All rights reserved.

  3. Parent-based diagnosis of ADHD is as accurate as a teacher-based diagnosis of ADHD.

    PubMed

    Bied, Adam; Biederman, Joseph; Faraone, Stephen

    2017-04-01

    To review the literature evaluating the psychometric properties of parent and teacher informants relative to a gold-standard ADHD diagnosis in pediatric populations. We included studies that included both a parent and teacher informant, a gold-standard diagnosis, and diagnostic accuracy metrics. Potential confounds were evaluated. We also assessed the 'OR' and the 'AND' rules for combining informant reports. Eight articles met inclusion criteria. The diagnostic accuracy for predicting gold standard ADHD diagnoses did not differ between parents and teachers. Sample size, sample type, participant drop-out, participant age, participant gender, geographic area of the study, and date of study publication were assessed as potential confounds. Parent and teachers both yielded moderate to good diagnostic accuracy for ADHD diagnoses. Parent reports were statistically indistinguishable from those of teachers. The predictive features of the 'OR' and 'AND' rules are useful in evaluating approaches to better integrating information from these informants.

  4. Poly(1-vinylimidazole) functionalized magnetic ion imprinted polymer for fast and selective extraction of trace gold in geological, environmental and biological samples followed by graphite furnace atomic absorption spectrometry detection

    NASA Astrophysics Data System (ADS)

    Zhao, Bingshan; He, Man; Chen, Beibei; Xu, Hongrun; Hu, Bin

    2018-05-01

    In this study, poly(1-vinylimidazole) functionalized gold ion imprinted polymer coated magnetic nanoparticles (MNPs@PVIM-Au-IIP) were prepared and characterized. The adsorption behaviors of the prepared MNPs@PVIM-Au-IIP toward gold ions (Au(III)) were studied, it was found that MNPs@PVIM-Au-IIP has good selectivity, high adsorption capacity (185.4 mg g-1) and fast adsorption kinetic for Au(III). Based on it, a new method of ion imprinted magnetic solid phase extraction (II-MSPE) coupled with graphite furnace atomic absorption spectrometry (GFAAS) detection was proposed for the analysis of trace Au(III) in real samples with complicated matrix. Factors affecting MSPE including sample pH, desorption reagent, elution concentration and volume, elution time, sample volume and adsorption time were optimized. With high enrichment factor of 100-fold, the detection limit of the proposed method is 7.9 ng L-1 for Au(III) with the relative standard deviation of 7.4% (c = 50 ng L-1, n = 7). In order to validate the accuracy of the proposed method, the Certified Reference Material of GBW07293 geological sample (platinpalladium ore) was analyzed, and the determined value was in good agreement with the certified value. The proposed II-MSPE-GFAAS method is simple, fast, selective, sensitive and has been successfully applied in the determination of trace Au in ore, sediment, environmental water and human urine samples with satisfactory results.

  5. Is a mobile emergency severity index (ESI) triage better than the paper ESI?

    PubMed

    Savatmongkorngul, Sorravit; Yuksen, Chaiyaporn; Suwattanasilp, Chanakarn; Sawanyawisuth, Kittisak; Sittichanbuncha, Yuwares

    2017-12-01

    This study aims to evaluate the mobile emergency severity index (ESI) tool in terms of validity compared with the original ESI triage. The original ESI and mobile ESI were used with patients at the Department of Emergency Medicine, Ramathibodi Hospital, Thailand. Eligible patients were evaluated by sixth-year medical students/emergency physicians using either the original or mobile ESI. The ESI results for each patient were compared with the standard ESI. Concordance and kappa statistics were calculated for pairs of the evaluators. There were 486 patients enrolled in the study; 235 patients (48.4%) were assessed using the mobile ESI, and 251 patients (51.6%) were in the original ESI group. The baseline characteristics of patients in both groups were mostly comparable except for the ED visit time. The percentages of concordance and kappa statistics in the original ESI group were lower than in the mobile group in all three comparisons (medical students vs gold standard, emergency physicians vs gold standard, and medical students vs emergency physicians). The highest kappa in the original ESI group is 0.69, comparing emergency physicians vs gold standard, while the lowest kappa in the application group is 0.84 comparing the medical students vs gold standard. Both medical students and emergency physicians are more confident with the mobile ESI application triage. In conclusion, the mobile ESI has better inter-rater reliability, and is more user-friendly than the original paper form.

  6. Mines, prospects, and occurrences of metallic (excluding gold), pegmatite, and rare-earth mineral commodities in the Greenville 1 degree by 2 degrees Quadrangle, South Carolina, Georgia, and North Carolina

    USGS Publications Warehouse

    D'Agostino, John P.; Zupan, Alan Jon; Maybin, Arthur H.; Abrams, Charlotte E.; German, Jerry M.

    1994-01-01

    All of the known mines, prospects, and occurrences of metallic (excluding gold, pegmatite, and rare-earth mineral commodities for the Greenville 1° x 2° quadrangle are tabulated in this report. The table lists, in consecutive order for each county (fig. 1), the map number of each item, which correlates and locates the item on the accompanying Greenville 1° x 2° quadrangle map. The known name of the feature; the 7.5' topographic map on the which the commodity site is located; the Universal Transverse Mercator (UTM) northing and easting grid coordinates from the appropriate 7.5' topographic map; the commodity; remarks; and references are also listed. Some locations are known, but many sites are not verified and their locations are only approximate. References are listed in References Cited and referred to by number to save space.

  7. Diagnostic accuracy of transesophageal echocardiogram for the detection of patent foramen ovale: a meta-analysis.

    PubMed

    Mojadidi, Mohammad Khalid; Bogush, Nikolay; Caceres, Jose Diego; Msaouel, Pavlos; Tobis, Jonathan M

    2014-07-01

    Patent foramen ovale (PFO) is a remnant of the fetal circulation present in 20% of the population. Right-to-left shunting (RLS) through a PFO has been linked to the pathophysiology of stroke, migraine with aura, and hypoxemia. While different imaging modalities including transcranial Doppler, intra-cardiac echo, and transthoracic echo (TTE) have often been used to detect RLS, transesophageal echo (TEE) bubble study remains the gold standard for diagnosing PFO. The aim of this study was to determine the relative accuracy of TEE in the detection of PFO. A systematic review of Medline, using a standard approach for meta-analysis, was performed for all prospective studies assessing accuracy of TEE in the detection of PFO using confirmation by autopsy, cardiac surgery, and/or catheterization as the reference. Search results revealed 3105 studies; 4 met inclusion criteria. A total of 164 patients were included. TEE had a weighted sensitivity of 89.2% (95% CI: 81.1-94.7%) and specificity of 91.4% (95% CI: 82.3-96.8%) to detect PFO. The overall positive likelihood ratio (LR+) was 5.93 (95% CI: 1.30-27.09) and the overall negative likelihood ratio (LR-) was 0.22 (95% CI: 0.08-0.56). While TEE bubble study is considered to be the gold standard modality for diagnosing PFO, some PFOs may still be missed or misdiagnosed. It is important to understand the limitations of TEE and perhaps use other highly sensitive screening tests, such as transcranial doppler (TCD), in conjunction with TEE before scheduling a patient for transcatheter PFO closure. © 2013, Wiley Periodicals, Inc.

  8. Flameless atomic-absorption determination of gold in geological materials

    USGS Publications Warehouse

    Meier, A.L.

    1980-01-01

    Gold in geologic material is dissolved using a solution of hydrobromic acid and bromine, extracted with methyl isobutyl ketone, and determined using an atomic-absorption spectrophotometer equipped with a graphite furnace atomizer. A comparison of results obtained by this flameless atomic-absorption method on U.S. Geological Survey reference rocks and geochemical samples with reported values and with results obtained by flame atomic-absorption shows that reasonable accuracy is achieved with improved precision. The sensitivity, accuracy, and precision of the method allows acquisition of data on the distribution of gold at or below its crustal abundance. ?? 1980.

  9. A pneumatic Bionic Voice prosthesis-Pre-clinical trials of controlling the voice onset and offset.

    PubMed

    Ahmadi, Farzaneh; Noorian, Farzad; Novakovic, Daniel; van Schaik, André

    2018-01-01

    Despite emergent progress in many fields of bionics, a functional Bionic Voice prosthesis for laryngectomy patients (larynx amputees) has not yet been achieved, leading to a lifetime of vocal disability for these patients. This study introduces a novel framework of Pneumatic Bionic Voice Prostheses as an electronic adaptation of the Pneumatic Artificial Larynx (PAL) device. The PAL is a non-invasive mechanical voice source, driven exclusively by respiration with an exceptionally high voice quality, comparable to the existing gold standard of Tracheoesophageal (TE) voice prosthesis. Following PAL design closely as the reference, Pneumatic Bionic Voice Prostheses seem to have a strong potential to substitute the existing gold standard by generating a similar voice quality while remaining non-invasive and non-surgical. This paper designs the first Pneumatic Bionic Voice prosthesis and evaluates its onset and offset control against the PAL device through pre-clinical trials on one laryngectomy patient. The evaluation on a database of more than five hours of continuous/isolated speech recordings shows a close match between the onset/offset control of the Pneumatic Bionic Voice and the PAL with an accuracy of 98.45 ±0.54%. When implemented in real-time, the Pneumatic Bionic Voice prosthesis controller has an average onset/offset delay of 10 milliseconds compared to the PAL. Hence it addresses a major disadvantage of previous electronic voice prostheses, including myoelectric Bionic Voice, in meeting the short time-frames of controlling the onset/offset of the voice in continuous speech.

  10. A pneumatic Bionic Voice prosthesis—Pre-clinical trials of controlling the voice onset and offset

    PubMed Central

    Noorian, Farzad; Novakovic, Daniel; van Schaik, André

    2018-01-01

    Despite emergent progress in many fields of bionics, a functional Bionic Voice prosthesis for laryngectomy patients (larynx amputees) has not yet been achieved, leading to a lifetime of vocal disability for these patients. This study introduces a novel framework of Pneumatic Bionic Voice Prostheses as an electronic adaptation of the Pneumatic Artificial Larynx (PAL) device. The PAL is a non-invasive mechanical voice source, driven exclusively by respiration with an exceptionally high voice quality, comparable to the existing gold standard of Tracheoesophageal (TE) voice prosthesis. Following PAL design closely as the reference, Pneumatic Bionic Voice Prostheses seem to have a strong potential to substitute the existing gold standard by generating a similar voice quality while remaining non-invasive and non-surgical. This paper designs the first Pneumatic Bionic Voice prosthesis and evaluates its onset and offset control against the PAL device through pre-clinical trials on one laryngectomy patient. The evaluation on a database of more than five hours of continuous/isolated speech recordings shows a close match between the onset/offset control of the Pneumatic Bionic Voice and the PAL with an accuracy of 98.45 ±0.54%. When implemented in real-time, the Pneumatic Bionic Voice prosthesis controller has an average onset/offset delay of 10 milliseconds compared to the PAL. Hence it addresses a major disadvantage of previous electronic voice prostheses, including myoelectric Bionic Voice, in meeting the short time-frames of controlling the onset/offset of the voice in continuous speech. PMID:29466455

  11. Glenohumeral articular cartilage lesions: prospective comparison of non-contrast magnetic resonance imaging and findings at arthroscopy.

    PubMed

    Spencer, Brian A; Dolinskas, Carol A; Seymour, Peter A; Thomas, Stephen J; Abboud, Joseph A

    2013-09-01

    The purpose of this study was to assess the diagnostic sensitivity, specificity, accuracy, negative predictive value (NPV), positive predictive value (PPV), and test-retest reliability of magnetic resonance imaging (MRI) for detecting cartilage abnormalities of the glenohumeral joint in comparison with the gold standard of diagnostic arthroscopy. Forty-four patients with a preoperative non-contrast MRI study of their affected shoulder underwent arthroscopy by one surgeon for rotator cuff tendinopathy from 2009 to 2010. Articular cartilage defects were prospectively recorded and graded according to the International Cartilage Repair Society classification system at the time of arthroscopy. One year after surgery, the preoperative MRI were reviewed by a board-certified radiologist and the treating surgeon for articular cartilage defects of both the humeral head and the glenoid. Sensitivity, specificity, accuracy, and test-retest reliability were calculated. At arthroscopy, 43% of the shoulders were found to have articular cartilage defects. When the readers' findings were combined, the sensitivity of detecting humeral lesions on MRI was 32%; specificity, 80%; accuracy, 63%; PPV, 57%; and NPV, 66%. The sensitivity of detecting glenoid lesions was 31%; specificity, 86%; accuracy, 76%; PPV, 33%; and NPV, 85%. This study finds that the overall accuracy of MRI in detecting articular cartilage damage in patients with the clinical diagnosis of subacromial pathology is moderate. Level II, development of diagnostic criteria based on consecutive patients with universally applied reference "gold" standard. Copyright © 2013 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  12. Recurrent rotator cuff tear: is ultrasound imaging reliable?

    PubMed

    Gilat, Ron; Atoun, Ehud; Cohen, Ornit; Tsvieli, Oren; Rath, Ehud; Lakstein, Dror; Levy, Ofer

    2018-02-02

    The diagnostic workup of the painful shoulder after rotator cuff repair (RCR) can be quite challenging. The aim of this study was to assess the reliability of ultrasonography (US) for the detection of recurrent rotator cuff tears in patients with shoulder pain after RCR. We hypothesized that US for the diagnosis of recurrent rotator cuff tear after RCR would not prove to be reliable when compared with surgical arthroscopic confirmation (gold standard). In this cohort study (diagnosis), we retrospectively analyzed the data of 39 patients with shoulder pain after arthroscopic RCR who had subsequently undergone US, followed by revision arthroscopy. The rotator cuff was evaluated first using US for the presence of retears. Thereafter, revision arthroscopy was performed, and the diagnosis was either established or disproved. The sensitivity and specificity of US were assessed in reference to revision arthroscopy (gold standard). A rotator cuff retear was indicated by US in 21 patients (54%) and by revision arthroscopy in 26 patients (67%). US showed a sensitivity of 80.8% and specificity of 100% in the diagnosis of rotator cuff retears. Omission of partial rotator cuff retears resulted in a spike in sensitivity to 94.7%, with 100% specificity remaining. US imaging is a highly sensitive and specific test for the detection of recurrent rotator cuff tears, as confirmed by revision arthroscopy, in patients with a painful shoulder after primary RCR. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  13. Estimation of the diagnostic performance of two ELISAs to detect PCV2 antibodies in pig sera using a Bayesian method.

    PubMed

    Fablet, C; Rose, N; Bernard, C; Messager, I; Piel, Y; Grasland, B

    2017-11-01

    This study was designed to assess the diagnostic characteristics of two PCV2 ELISAs without a gold standard. Four hundred and sixty-five serum samples from finishing pigs (25 herds) not vaccinated against PCV2 were used. Samples were tested by two ELISAs: an in-house ELISA (I-ELISA) and the commercial SERELISA ® PCV2 Ab Mono Blocking kit (S-ELISA). A ROC curve was used to assess the S-ELISA's optimal threshold by taking the I-ELISA as a reference and using the cut-off previously determined by comparison to an cccmonolayer assay (IPMA). This led to an S-ELISA result ≥170 being considered as positive. The sensitivity (Se) and specificity (Sp) of each ELISA were then estimated without a gold standard using a Bayesian approach. The mean Se and Sp values of the I-ELISA were slightly higher than those of the S-ELISA (mean Se I-ELISA=0.90 vs. mean Se S-ELISA=0.86; mean Sp I-ELISA=0.92 vs. mean Sp S-ELISA=0.85). However, the 95% credibility intervals (CI95%) overlapped (Se I-ELISA CI95%=0.85-0.95 vs. Se S-ELISA CI95%=0.82-0.90; Sp I-ELISA CI95%=0.82-0.98 vs. Sp S-ELISA CI95%=0.75-0.94). Both ELISAs appeared to be valuable tools for detecting PCV2 antibodies. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Diagnostic accuracy of patch test in children with food allergy.

    PubMed

    Caglayan Sozmen, Sule; Povesi Dascola, Carlotta; Gioia, Edoardo; Mastrorilli, Carla; Rizzuti, Laura; Caffarelli, Carlo

    2015-08-01

    The gold standard test for confirming whether a child has clinical hypersensitivity reactions to foods is the oral food challenge. Therefore, there is increasing interest in simpler diagnostic markers of food allergy, especially in children, to avoid oral food challenge. The goal of this study was to assess the diagnostic accuracy of atopy patch test in comparison with oral food challenge. We investigated 243 children (mean age, 51 months) referred for evaluation of suspected egg or cow's milk allergy. Skin prick test and atopy patch test were carried out, and after a 2 weeks elimination diet, oral food challenge was performed. Two hundred and forty-three children underwent OFC to the suspected food. We found clinically relevant food allergies in 40 (65%) children to egg and in 22 (35%) to cow's milk. The sensitivity of skin prick test for both milk and egg was 92%, specificity 91%, positive predictive value 35%, and negative predictive value of 93%. Sensitivity, specificity, positive predictive value, and negative predictive value of atopy patch test for both milk and egg were 21%, 73%, 20%, and 74%, respectively. Our study suggests that there is insufficient evidence for the routine use of atopy patch test for the evaluation of egg and cow's milk allergy. OFC remains gold standard for the diagnosis of egg and milk allergy even in the presence of high costs in terms of both time and risks during application. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. Assessment of medial coronoid disease in 180 canine lame elbow joints: a sensitivity and specificity comparison of radiographic, computed tomographic and arthroscopic findings.

    PubMed

    Villamonte-Chevalier, A; van Bree, H; Broeckx, Bjg; Dingemanse, W; Soler, M; Van Ryssen, B; Gielen, I

    2015-09-25

    Diagnostic imaging is essential to assess the lame patient; lesions of the elbow joint have traditionally been evaluated radiographically, however computed tomography (CT) has been suggested as a useful technique to diagnose various elbow pathologies. The primary objective of this study was to determine the sensitivity and specificity of CT to assess medial coronoid disease (MCD), using arthroscopy as gold standard. The secondary objective was to ascertain the radiographic sensitivity and specificity for MCD compared with CT. For this study 180 elbow joints were assessed, of which 141 had been examined with radiography, CT and arthroscopy; and 39 joints, had radiographic and CT assessment. Sensitivity and specificity were calculated for CT and radiographic findings using available statistical software. Sensitivity and specificity of CT using arthroscopy as gold standard resulted in high values for sensitivity (100 %) and specificity (93 %) for the assessment of MCD. For the radiographic evaluation, a sensitivity of 98 % and specificity of 64 - 69 % using CT as the technique of reference, were found. These results suggest that in case of doubt during radiographic assessment, CT could be used as a non-invasive technique to assess the presence of MCD. Based on the high sensitivity and specificity obtained in this study it has been considered that CT, rather than arthroscopy, is the preferred noninvasive technique to assess MCD lesions of the canine elbow joint.

  16. Discourse following award of Kepler Gold Medal. [Kepler Laws, planetary astronomy and physics, and Jupiter studies

    NASA Technical Reports Server (NTRS)

    Kuiper, G. P.

    1973-01-01

    Kuiper briefly reviews Kepler's contributions to the field of planetary astronomy and physics, along with references to his own background in the study of stars, planets, and the solar system. He mentions his participation in NASA programs related to planetary astronomy. He concludes his remarks with thanks for being honored by the award of the Kepler Gold Medal.

  17. A Profilometry-Based Dentifrice Abrasion Method for V8 Brushing Machines Part II: Comparison of RDA-PE and Radiotracer RDA Measures.

    PubMed

    Schneiderman, Eva; Colón, Ellen; White, Donald J; St John, Samuel

    2015-01-01

    The purpose of this study was to compare the abrasivity of commercial dentifrices by two techniques: the conventional gold standard radiotracer-based Radioactive Dentin Abrasivity (RDA) method; and a newly validated technique based on V8 brushing that included a profilometry-based evaluation of dentin wear. This profilometry-based method is referred to as RDA-Profilometry Equivalent, or RDA-PE. A total of 36 dentifrices were sourced from four global dentifrice markets (Asia Pacific [including China], Europe, Latin America, and North America) and tested blindly using both the standard radiotracer (RDA) method and the new profilometry method (RDA-PE), taking care to follow specific details related to specimen preparation and treatment. Commercial dentifrices tested exhibited a wide range of abrasivity, with virtually all falling well under the industry accepted upper limit of 250; that is, 2.5 times the level of abrasion measured using an ISO 11609 abrasivity reference calcium pyrophosphate as the reference control. RDA and RDA-PE comparisons were linear across the entire range of abrasivity (r2 = 0.7102) and both measures exhibited similar reproducibility with replicate assessments. RDA-PE assessments were not just linearly correlated, but were also proportional to conventional RDA measures. The linearity and proportionality of the results of the current study support that both methods (RDA or RDA-PE) provide similar results and justify a rationale for making the upper abrasivity limit of 250 apply to both RDA and RDA-PE.

  18. 40 CFR 421.254 - Standards of performance for new sources.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... average mg/troy ounce of gold refined electrolytically Lead 5.544 2.574 Mercury 2.970 1.188 Silver 5.742 2... property Maximum for any 1 day Maximum for monthly average mg/troy ounce of gold and silver smelted Lead 0... reduced in solution Lead 0.112 0.052 Mercury 0.060 0.024 Silver 0.116 0.048 Zinc 0.408 0.168 Gold 0.040...

  19. 40 CFR 421.261 - Specialized definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... apply to this subpart. (b) The term precious metals shall mean gold, platinum, palladium, rhodium, iridium, osmium, and ruthenium. (c) The term Combined Metals, shall mean the total of gold, platinum and... AND STANDARDS NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY Secondary Precious Metals...

  20. Homemade thermometry instruments in the field.

    PubMed

    Pasquier, Mathieu; Rousson, Valentin; Zen Ruffinen, Grégoire; Hugli, Olivier

    2012-03-01

    Esophageal temperature is the gold standard for in-the-field temperature monitoring in hypothermic victims with cardiac arrest. For practical reasons, some mountain rescue teams use homemade esophageal thermometers to measure esophageal temperature; these consist of nonmedical inside/outside temperature monitoring instruments that have been modified to allow for esophageal insertion. We planned a study to determine the accuracy of such thermometers. Two of the same model of digital cabled indoor/outdoor thermometer were modified and tested in comparison with a reference thermometer. The thermometers were tested in a water bath at different temperatures between 10°C and 35.2°C. Three hundred measurements were taken with each thermometer. Our experimental study showed that both homemade thermometers provided a good correlation and a clinically acceptable agreement in comparison with the reference thermometer. Measurements were within 0.5°C in comparison with the reference thermometer 97.5% of the time. The homemade thermometers performed well in vitro, in comparison with a reference thermometer. However, because these devices in their original form are not designed for clinical use, their use should be restricted to situations when the use of a conventional esophageal thermometer is impossible. Copyright © 2012 Wilderness Medical Society. Published by Elsevier Inc. All rights reserved.

  1. Identification of Reference Genes for RT-qPCR Data Normalization in Cannabis sativa Stem Tissues.

    PubMed

    Mangeot-Peter, Lauralie; Legay, Sylvain; Hausman, Jean-Francois; Esposito, Sergio; Guerriero, Gea

    2016-09-15

    Gene expression profiling via quantitative real-time PCR is a robust technique widely used in the life sciences to compare gene expression patterns in, e.g., different tissues, growth conditions, or after specific treatments. In the field of plant science, real-time PCR is the gold standard to study the dynamics of gene expression and is used to validate the results generated with high throughput techniques, e.g., RNA-Seq. An accurate relative quantification of gene expression relies on the identification of appropriate reference genes, that need to be determined for each experimental set-up used and plant tissue studied. Here, we identify suitable reference genes for expression profiling in stems of textile hemp (Cannabis sativa L.), whose tissues (isolated bast fibres and core) are characterized by remarkable differences in cell wall composition. We additionally validate the reference genes by analysing the expression of putative candidates involved in the non-oxidative phase of the pentose phosphate pathway and in the first step of the shikimate pathway. The goal is to describe the possible regulation pattern of some genes involved in the provision of the precursors needed for lignin biosynthesis in the different hemp stem tissues. The results here shown are useful to design future studies focused on gene expression analyses in hemp.

  2. Endoscopic Devices for Obesity.

    PubMed

    Sampath, Kartik; Dinani, Amreen M; Rothstein, Richard I

    2016-06-01

    The obesity epidemic, recognized by the World Health Organization in 1997, refers to the rising incidence of obesity worldwide. Lifestyle modification and pharmacotherapy are often ineffective long-term solutions; bariatric surgery remains the gold standard for long-term obesity weight loss. Despite the reported benefits, it has been estimated that only 1% of obese patients will undergo surgery. Endoscopic treatment for obesity represents a potential cost-effective, accessible, minimally invasive procedure that can function as a bridge or alternative intervention to bariatric surgery. We review the current endoscopic bariatric devices including space occupying devices, endoscopic gastroplasty, aspiration technology, post-bariatric surgery endoscopic revision, and obesity-related NOTES procedures. Given the diverse devices already FDA approved and in development, we discuss the future directions of endoscopic therapies for obesity.

  3. Suppressing correlations in massively parallel simulations of lattice models

    NASA Astrophysics Data System (ADS)

    Kelling, Jeffrey; Ódor, Géza; Gemming, Sibylle

    2017-11-01

    For lattice Monte Carlo simulations parallelization is crucial to make studies of large systems and long simulation time feasible, while sequential simulations remain the gold-standard for correlation-free dynamics. Here, various domain decomposition schemes are compared, concluding with one which delivers virtually correlation-free simulations on GPUs. Extensive simulations of the octahedron model for 2 + 1 dimensional Kardar-Parisi-Zhang surface growth, which is very sensitive to correlation in the site-selection dynamics, were performed to show self-consistency of the parallel runs and agreement with the sequential algorithm. We present a GPU implementation providing a speedup of about 30 × over a parallel CPU implementation on a single socket and at least 180 × with respect to the sequential reference.

  4. A Unified Approach to Genotype Imputation and Haplotype-Phase Inference for Large Data Sets of Trios and Unrelated Individuals

    PubMed Central

    Browning, Brian L.; Browning, Sharon R.

    2009-01-01

    We present methods for imputing data for ungenotyped markers and for inferring haplotype phase in large data sets of unrelated individuals and parent-offspring trios. Our methods make use of known haplotype phase when it is available, and our methods are computationally efficient so that the full information in large reference panels with thousands of individuals is utilized. We demonstrate that substantial gains in imputation accuracy accrue with increasingly large reference panel sizes, particularly when imputing low-frequency variants, and that unphased reference panels can provide highly accurate genotype imputation. We place our methodology in a unified framework that enables the simultaneous use of unphased and phased data from trios and unrelated individuals in a single analysis. For unrelated individuals, our imputation methods produce well-calibrated posterior genotype probabilities and highly accurate allele-frequency estimates. For trios, our haplotype-inference method is four orders of magnitude faster than the gold-standard PHASE program and has excellent accuracy. Our methods enable genotype imputation to be performed with unphased trio or unrelated reference panels, thus accounting for haplotype-phase uncertainty in the reference panel. We present a useful measure of imputation accuracy, allelic R2, and show that this measure can be estimated accurately from posterior genotype probabilities. Our methods are implemented in version 3.0 of the BEAGLE software package. PMID:19200528

  5. Direct and Absolute Quantification of over 1800 Yeast Proteins via Selected Reaction Monitoring*

    PubMed Central

    Lawless, Craig; Holman, Stephen W.; Brownridge, Philip; Lanthaler, Karin; Harman, Victoria M.; Watkins, Rachel; Hammond, Dean E.; Miller, Rebecca L.; Sims, Paul F. G.; Grant, Christopher M.; Eyers, Claire E.; Beynon, Robert J.

    2016-01-01

    Defining intracellular protein concentration is critical in molecular systems biology. Although strategies for determining relative protein changes are available, defining robust absolute values in copies per cell has proven significantly more challenging. Here we present a reference data set quantifying over 1800 Saccharomyces cerevisiae proteins by direct means using protein-specific stable-isotope labeled internal standards and selected reaction monitoring (SRM) mass spectrometry, far exceeding any previous study. This was achieved by careful design of over 100 QconCAT recombinant proteins as standards, defining 1167 proteins in terms of copies per cell and upper limits on a further 668, with robust CVs routinely less than 20%. The selected reaction monitoring-derived proteome is compared with existing quantitative data sets, highlighting the disparities between methodologies. Coupled with a quantification of the transcriptome by RNA-seq taken from the same cells, these data support revised estimates of several fundamental molecular parameters: a total protein count of ∼100 million molecules-per-cell, a median of ∼1000 proteins-per-transcript, and a linear model of protein translation explaining 70% of the variance in translation rate. This work contributes a “gold-standard” reference yeast proteome (including 532 values based on high quality, dual peptide quantification) that can be widely used in systems models and for other comparative studies. PMID:26750110

  6. Experimental findings on the underwater measurements uncertainty of speed of sound and the alignment system

    NASA Astrophysics Data System (ADS)

    Santos, T. Q.; Alvarenga, A. V.; Oliveira, D. P.; Mayworm, R. C.; Souza, R. M.; Costa-Félix, R. P. B.

    2016-07-01

    Speed of sound is an important quantity to characterize reference materials for ultrasonic applications, for instance. The alignment between the transducer and the test body is an key activity in order to perform reliable and consistent measurement. The aim of this work is to evaluate the influence of the alignment system to the expanded uncertainty of such measurement. A stainless steel cylinder was previously calibrated on an out of water system typically used for calibration of non-destructive blocks. Afterwards, the cylinder was calibrated underwater with two distinct alignment system: fixed and mobile. The values were statistically compared to the out-of-water measurement, considered the golden standard for such application. For both alignment systems, the normalized error was less than 0.8, leading to conclude that the both measurement system (under and out-of-water) do not diverge significantly. The gold standard uncertainty was 2.7 m-s-1, whilst the fixed underwater system resulted in 13 m-s-1, and the mobile alignment system achieved 6.6 m-s-1. After the validation of the underwater system for speed of sound measurement, it will be applied to certify Encapsulated Tissue Mimicking Material as a reference material for biotechnology application.

  7. Practical no-gold-standard evaluation framework for quantitative imaging methods: application to lesion segmentation in positron emission tomography

    PubMed Central

    Jha, Abhinav K.; Mena, Esther; Caffo, Brian; Ashrafinia, Saeed; Rahmim, Arman; Frey, Eric; Subramaniam, Rathan M.

    2017-01-01

    Abstract. Recently, a class of no-gold-standard (NGS) techniques have been proposed to evaluate quantitative imaging methods using patient data. These techniques provide figures of merit (FoMs) quantifying the precision of the estimated quantitative value without requiring repeated measurements and without requiring a gold standard. However, applying these techniques to patient data presents several practical difficulties including assessing the underlying assumptions, accounting for patient-sampling-related uncertainty, and assessing the reliability of the estimated FoMs. To address these issues, we propose statistical tests that provide confidence in the underlying assumptions and in the reliability of the estimated FoMs. Furthermore, the NGS technique is integrated within a bootstrap-based methodology to account for patient-sampling-related uncertainty. The developed NGS framework was applied to evaluate four methods for segmenting lesions from F-Fluoro-2-deoxyglucose positron emission tomography images of patients with head-and-neck cancer on the task of precisely measuring the metabolic tumor volume. The NGS technique consistently predicted the same segmentation method as the most precise method. The proposed framework provided confidence in these results, even when gold-standard data were not available. The bootstrap-based methodology indicated improved performance of the NGS technique with larger numbers of patient studies, as was expected, and yielded consistent results as long as data from more than 80 lesions were available for the analysis. PMID:28331883

  8. [Evaluation of Xpert® MTB/RIF technique for Mycobacterium tuberculosis complex detection in extra-respiratory specimens].

    PubMed

    García, Patricia; Balcells, M Elvira; Castillo, Claudia; Miranda, Carolina; Geoffroy, Enrique; Román, Juan C; Wozniak, Aniela

    2017-08-01

    Extra-pulmonary tuberculosis (TB) represents the 26.2% of total TB cases in Chile. Culture is the gold standard method, but the process is extremely slow. Xpert®MTB/RIF technique detects Mycobacterium tuberculosis complex (MTBc) through real time PCR in less than 3 h. However, it has been validated only for respiratory specimens. We aimed to determine the performance of Xpert®MTB/RIF test in detecting MTBc in extra-respiratory specimens compared with a combined gold standard consisting in a positive (liquid and solid) mycobacterial culture and/or a positive validated molecular method (q-RPC, Cobas®TaqMan®-MTB). Fifty extra-respiratory specimens were analyzed, from which 25 were positive and 25 negative for MTBc based on the combined gold standard. The 25 positive specimens had a positive result by Xpert®MTB/RIF; from the 25 negative specimens, 24 had a negative result and one had a positive result. We obtained an overall concordance of 98% between Xpert®MTB/RIF and the combined gold standard. Xpert®MTB/RIF test was able to detect 12 smear-negative specimens and 3 culture-negative specimens, all of them corresponding to extra-pulmonary TB cases. Xpert®MTB/RIF showed similar sensitivity to q-RPC in detecting MTBc in extra-respiratory specimens. This procedure allowed a substantial reduction in the time of diagnosis.

  9. On-line hemodiafiltration. Gold standard or top therapy?

    PubMed

    Passlick-Deetjen, Jutta; Pohlmeier, Robert

    2002-01-01

    In summary, on-line HDF is an extracorporeal blood purification therapy with increased convective removal of uremic toxins as compared to the most frequently used low- or high-flux HD therapy. The clinical advantages of on-line HDF have shown to be dose dependent, which makes on-line HDF superior to other therapies with less convective solute removal. Among the therapies with high convective solute removal, i.e. on-line HDF, on-line HF and double high-flux dialysis, it is difficult to finally decide on the best therapy, as direct comparisons of these therapies are not performed. Theoretical considerations like the relative to on-line HDF lower achievable Kt/Vurea with on-line HF, allow to state that on-line HDF is the top therapy now available for patients with ESRD. A gold standard may be defined as something with which everything else is compared if one tries to establish it in the respective field. In order to declare on-line HDF as the gold standard in renal replacement therapy, we need more direct comparisons of on-line HDF with other therapies, including mortality as an outcome parameter. However, based on our current knowledge, it does not seem to be too speculative that high-quality clinical studies will establish on-line HDF in the next years as the new gold standard in renal replacement therapy.

  10. Daily sodium and potassium excretion can be estimated by scheduled spot urine collections.

    PubMed

    Doenyas-Barak, Keren; Beberashvili, Ilia; Bar-Chaim, Adina; Averbukh, Zhan; Vogel, Ofir; Efrati, Shai

    2015-01-01

    The evaluation of sodium and potassium intake is part of the optimal management of hypertension, metabolic syndrome, renal stones, and other conditions. To date, no convenient method for its evaluation exists, as the gold standard method of 24-hour urine collection is cumbersome and often incorrectly performed, and methods that use spot or shorter collections are not accurate enough to replace the gold standard. The aim of this study was to evaluate the correlation and agreement between a new method that uses multiple-scheduled spot urine collection and the gold standard method of 24-hour urine collection. The urine sodium or potassium to creatinine ratios were determined for four scheduled spot urine samples. The mean ratios of the four spot samples and the ratios of each of the single spot samples were corrected for estimated creatinine excretion and compared to the gold standard. A significant linear correlation was demonstrated between the 24-hour urinary solute excretions and estimated excretion evaluated by any of the scheduled spot urine samples. The correlation of the mean of the four spots was better than for any of the single spots. Bland-Altman plots showed that the differences between these measurements were within the limits of agreement. Four scheduled spot urine samples can be used as a convenient method for estimation of 24-hour sodium or potassium excretion. © 2015 S. Karger AG, Basel.

  11. Proactive dairy cattle disease control in the UK: veterinary surgeons' involvement and associated characteristics

    PubMed Central

    Higgins, H. M.; Huxley, J. N.; Wapenaar, W.; Green, M. J.

    2013-01-01

    Characteristics of 94 veterinary surgeons associated with delivering preventive herd-level strategies to control mastitis, lameness and Johne's disease were investigated using two multinomial models. The response variables were ‘Gold Standard Monitoring’ (including on-going data analysis, risk assessments and laboratory testing), and a lower level of involvement called ‘Regular Control Advice’. Although the sample was biased towards those who spend the majority of their time with dairy cows, 69 per cent currently had no involvement in Gold Standard Monitoring for lameness, 60 per cent no involvement with Johne's, and 52 per cent no involvement with mastitis. The final model predicted that an assistant without a postgraduate cattle qualification, who had spent no time on dairy cattle continuous professional development (CPD) in the last year, had an 88 per cent chance of having no involvement with Gold Standard Monitoring for any disease, versus <5 per cent chance for a CPD ‘enriched’ partner with a postgraduate cattle qualification; there was <1 per cent chance this assistant would be involved with Gold Standard Monitoring of all three diseases on one or more farms, versus a 58 per cent chance for this partner. CPD and employment status were also associated with markedly different probabilities for delivering Regular Control Advice. Increased postgraduate education may further veterinary involvement of this nature. PMID:23887976

  12. Prospective comparison of RT-PCR/ESI-MS to Prodesse ProFlu Plus and Cepheid GenXpert for the detection of Influenza A and B viruses.

    PubMed

    Hardick, Justin; Dugas, Andrea; Goheen, Joshua; Rothman, Richard; Gaydos, Charlotte

    2015-03-01

    RT-PCR/ESI-MS has previously demonstrated the capability to detect and identify respiratory viral pathogens in nasopharyngeal swabs. This study expands on previous research by performing a prospective evaluation of RT-PCR/ESI-MS to detect and identify Influenza A and B viruses compared to Prodesse ProFlu Plus and combined ProFlu Plus and Cepheid Xpert Flu. ProFlu Plus was also used as a gold standard for comparison for respiratory syncytial virus detection. Using ProFlu Plus as a gold standard, RT-PCR/ESI-MS had sensitivity and specificity of 82.1% (23/28) and 100% (258/258), respectively, for Influenza A, 100% (16/16) and 99.6% (269/270), respectively for Influenza B, and 88.6% (39/44) and 99.6% (241/242) for any Influenza virus. Using matching results from ProFlu Plus and Xpert Flu as a gold standard, RT-PCR/ESI-MS had 85.2% (23/27) and 100% (259/259) sensitivity and specificity respectively for Influenza A, 100% (14/14) and 99.6% (270/272), respectively for Influenza B virus. Overall, RT-PCR/ESI-MS was not as sensitive as the combined gold standard of ProFlu Plus and Xpert Flu, although it has the capability of detecting other respiratory viruses. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Factors influencing the decline in lung density in a Danish lung cancer screening cohort.

    PubMed

    Shaker, Saher B; Dirksen, Asger; Lo, Pechin; Skovgaard, Lene T; de Bruijne, Marleen; Pedersen, Jesper H

    2012-11-01

    Lung cancer screening trials provide an opportunity to study the natural history of emphysema by using computed tomography (CT) lung density as a surrogate parameter. In the Danish Lung Cancer Screening Trial, 2,052 participants were included. At screening rounds, smoking habits were recorded and spirometry was performed. CT lung density was measured as the volume-adjusted 15th percentile density (PD15). A mixed effects model was used with former smoking males with <30 pack-yrs and without airflow obstruction (AFO) at entry as a reference group. At study entry, 893 (44%) participants had AFO. For the reference group, PD15 was 72.6 g·L(-1) with an annual decline of -0.33 g·L(-1). Female sex and current smoking increased PD15 at baseline, 17.3 g·L(-1) (p<0.001) and 10 g·L(-1) (p<0.001), respectively; and both increased the annual decline in PD15 (female: -0.3 g·L(-1); current smoking: -0.4 g·L(-1)). The presence and severity of AFO was a strong predictor of low PD15 at baseline (Global Initiative for Chronic Obstructive Lung Disease (GOLD) I: -1.4 g·L(-1); GOLD II: -6.3 g·L(-1); GOLD III: -17 g·L(-1)) and of increased annual decline in PD15 (GOLD I: -0.2 g·L(-1); GOLD II: -0.5 g·L(-1); GOLD III: -0.5 g·L(-1)). Female sex, active smoking and the presence of AFO are associated with accelerated decline in lung density.

  14. Optical absorption and photoluminescence studies of gold nanoparticles deposited on porous silicon

    PubMed Central

    2013-01-01

    We present an investigation on a coupled system consists of gold nanoparticles and silicon nanocrystals. Gold nanoparticles (AuNPs) embedded into porous silicon (PSi) were prepared using the electrochemical deposition method. Scanning electron microscope images and energy-dispersive X-ray results indicated that the growth of AuNPs on PSi varies with current density. X-ray diffraction analysis showed the presence of cubic gold phases with crystallite sizes around 40 to 58 nm. Size dependence on the plasmon absorption was studied from nanoparticles with various sizes. Comparison with the reference sample, PSi without AuNP deposition, showed a significant blueshift with decreasing AuNP size which was explained in terms of optical coupling between PSi and AuNPs within the pores featuring localized plasmon resonances. PMID:23331761

  15. Determination of the occurrence of gold in an unoxidized Carlin-type ore sample using synchrotron radiation

    USGS Publications Warehouse

    Chen, J.R.; Chao, E.C.T.; Minkin, J.A.; Back, J.M.; Bagby, W.C.; Rivers, M.L.; Sutton, S.R.; Gordon, B.M.; Hanson, A.L.; Jones, K.W.

    1987-01-01

    The occurrence of the so-called invisible gold in two unoxidized Carlin-type gold samples from Nevada has been determined using synchrotron X-ray fluorescence (SXRF) analysis at the National Synchrotron Light Source, Brookhaven National Laboratory. A bedded sample from the East ore zone of the Carlin deposit and a breccia sample from Horse Canyon were analyzed. Preliminary results show that gold is found only in the Horse Canyon breccia sample. Experimental details including other X-ray line and diffraction peak interferences, standards used, and minimum detection limits (MDLs) are discussed. Gold, with a MDL range of 0.8 to 3 ppm, was not detected in euhedral pyrite crystals except in the interior porous portion of one grain. Gold was detected in some parts of the matrix. The phase which contains gold has not yet been identified. The highest content of gold so far analyzed is about 40 ppm. There are interesting implications of these new findings. ?? 1987.

  16. Direct analysis of environmental and biological samples for total mercury with comparison of sequential atomic absorption and fluorescence measurements from a single combustion event

    NASA Astrophysics Data System (ADS)

    Cizdziel, James V.; Tolbert, Candice; Brown, Garry

    2010-02-01

    A Direct Mercury Analyzer (DMA) based on sample combustion, concentration of mercury by amalgamation with gold, and cold vapor atomic absorption spectrometry (CVAAS) was coupled to a mercury-specific cold vapor atomic fluorescence spectrometer (CVAFS). The purpose was to evaluate combustion-AFS, a technique which is not commercially available, for low-level analysis of mercury in environmental and biological samples. The experimental setup allowed for comparison of dual measurements of mercury (AAS followed by AFS) for a single combustion event. The AFS instrument control program was modified to properly time capture of mercury from the DMA, avoiding deleterious combustion products from reaching its gold traps. Calibration was carried out using both aqueous solutions and solid reference materials. The absolute detection limits for mercury were 0.002 ng for AFS and 0.016 ng for AAS. Recoveries for reference materials ranged from 89% to 111%, and the precision was generally found to be <10% relative standard deviation (RSD). The two methods produced similar results for samples of hair, finger nails, coal, soil, leaves and food stuffs. However, for samples with mercury near the AAS detection limit (e.g., filter paper spotted with whole blood and segments of tree rings) the signal was still quantifiable with AFS, demonstrating the lower detection limit and greater sensitivity of AFS. This study shows that combustion-AFS is feasible for the direct analysis of low levels of mercury in solid samples that would otherwise require time-consuming and contamination-prone digestion.

  17. Dental age assessment of Maltese children and adolescents. Development of a reference dataset and comparison with a United Kingdom Caucasian reference dataset.

    PubMed

    Elshehawi, Waleed; Alsaffar, Hani; Roberts, Graham; Lucas, Victoria; McDonald, Fraser; Camilleri, Simon

    2016-04-01

    The purpose of this study was to develop and validate a Reference Data Set for Dental Age Assessment of the Maltese population and compare the mean Age of Attainment to a UK Caucasian Reference Data Set. The Maltese Reference Data Set was developed from 1593 Dental Panoramic Tomograms of patients aged between 4 and 26 years, taken from the radiographic archives of the Dental Department, Mater Dei Hospital, Malta. Tooth Development Stages were recorded for all 16 maxillary and mandibular permanent teeth on the left side and both permanent third molars on the right, according to Demirjian's staging method. Summary and percentile data were calculated for each Tooth Development Stage, including the mean Age of Attainment. These means were used to estimate the Dental Age of each subject in the study sample using the simple unweighted average method. The estimated Dental Age was compared to the gold standard of the Chronological Age. Comparison of the Maltese and UK Caucasian Reference Data Set was by a series of t-tests, carried out for each paired Tooth Development Stage by gender. The mean Age of Attainment was slightly higher for the Maltese than the UK Caucasians in both males and females. However there was no statistically significant difference between the Chronological Age and Dental Age for either sex. Copyright © 2016 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  18. Assessment of cardiac time intervals using high temporal resolution real-time spiral phase contrast with UNFOLDed-SENSE.

    PubMed

    Kowalik, Grzegorz T; Knight, Daniel S; Steeden, Jennifer A; Tann, Oliver; Odille, Freddy; Atkinson, David; Taylor, Andrew; Muthurangu, Vivek

    2015-02-01

    To develop a real-time phase contrast MR sequence with high enough temporal resolution to assess cardiac time intervals. The sequence utilized spiral trajectories with an acquisition strategy that allowed a combination of temporal encoding (Unaliasing by fourier-encoding the overlaps using the temporal dimension; UNFOLD) and parallel imaging (Sensitivity encoding; SENSE) to be used (UNFOLDed-SENSE). An in silico experiment was performed to determine the optimum UNFOLD filter. In vitro experiments were carried out to validate the accuracy of time intervals calculation and peak mean velocity quantification. In addition, 15 healthy volunteers were imaged with the new sequence, and cardiac time intervals were compared to reference standard Doppler echocardiography measures. For comparison, in silico, in vitro, and in vivo experiments were also carried out using sliding window reconstructions. The in vitro experiments demonstrated good agreement between real-time spiral UNFOLDed-SENSE phase contrast MR and the reference standard measurements of velocity and time intervals. The protocol was successfully performed in all volunteers. Subsequent measurement of time intervals produced values in keeping with literature values and good agreement with the gold standard echocardiography. Importantly, the proposed UNFOLDed-SENSE sequence outperformed the sliding window reconstructions. Cardiac time intervals can be successfully assessed with UNFOLDed-SENSE real-time spiral phase contrast. Real-time MR assessment of cardiac time intervals may be beneficial in assessment of patients with cardiac conditions such as diastolic dysfunction. © 2014 Wiley Periodicals, Inc.

  19. Reduced Expiratory Flow Rate among Heavy Smokers Increases Lung Cancer Risk. Results from the National Lung Screening Trial–American College of Radiology Imaging Network Cohort

    PubMed Central

    Hopkins, Raewyn J.; Duan, Fenghai; Chiles, Caroline; Greco, Erin M.; Gamble, Greg D.; Aberle, Denise

    2017-01-01

    Rationale: Although epidemiological studies consistently show that chronic obstructive pulmonary disease is associated with an increased risk of lung cancer, debate exists as to whether there is a linear relationship between the severity of airflow limitation and lung cancer risk. Objectives: We examined this in a large, prospective study of older heavy smokers from the American College of Radiology Imaging Network subcohort of the National Lung Screening Trial (ACRIN). Airflow limitation was defined by prebronchodilator spirometry subgrouped according to Global Initiative for Chronic Obstructive Lung Disease (GOLD) grades 1–4. Methods: In the National Lung Screening Trial–ACRIN cohort of 18,473 screening participants, 6,436 had airflow limitation (35%) and 12,037 (65%) had no airflow limitation. From these groups, 758 lung cancer cases were prospectively identified. Participants with airflow limitation were stratified according to GOLD groups 1 (n = 1,607), 2 (n = 3,528), 3 (n = 1,083), and 4 (n = 211). Lung cancer incidence at study end (mean follow-up, 6.4 yr) was compared between the GOLD groups and those with no airflow limitation (referent group). Measurements and Main Results: Compared with those with no airflow limitation, where lung cancer incidence was 3.78/1,000 person years, incidence rates increased in a simple linear relationship: GOLD 1 (6.27/1,000 person yr); GOLD 2 (7.86/1,000 person yr); GOLD 3 (10.71/1,000 person yr); and GOLD 4 (13.25/1,000 person yr). All relationships were significant versus the reference group at a P value of 0.0001 or less. Conclusions: In a large prospective study of high-risk cigarette smokers, we report a strong linear relationship between increasing severity of airflow limitation and risk of lung cancer. PMID:28076701

  20. Comparison of standard- and low-tube voltage 320-detector row volume CT angiography in detection of intracranial aneurysms with digital subtraction angiography as gold standard.

    PubMed

    Sun, Gang; Ding, Juan; Lu, Yang; Li, Min; Li, Li; Li, Guo-ying; Zhang, Xu-ping

    2012-03-01

    The aim of this study was to prospectively assess the effect of low-tube voltage (80 kVp) 320-detector row volume computed tomographic (CT) angiography (L-VCTA) in the detection of intracranial aneurysms, with three-dimensional (3D) spin digital subtraction angiography (DSA) as the gold standard. Forty-eight patients with clinically suspected subarachnoid hemorrhages were divided into two groups. One group underwent L-VCTA and DSA, while the other group underwent conventional-tube voltage (120 kVp) volume CT angiography (C-VCTA) and DSA. Vascular enhancement, image quality, detection accuracy of aneurysms, and radiation dose were compared between the two groups. For objective image quality, the L-VCTA group had higher mean vessel attenuation, correlated with higher image noise and lower signal-to-noise ratio, than the C-VCTA group. For subjective image quality, there were no significant differences between the two groups regarding scores for arterial enhancement, depiction of small arterial detail, interference of venous structures, and overall image quality scores. The mean effective dose for the L-VCTA group was significantly lower than for the C-VCTA group (0.56 ± 0.25 vs 1.84 ± 0.002 mSv), with a reduction of radiation dose of 69.73%. With 3D DSA as the reference standard, the sensitivity, specificity, and accuracy in the L-VCTA and C-VCTA groups were 94.12%, 100%, 94.4% and 100%, 100%, and 100%, respectively. In both groups, there were significant correlations for maximum aneurysm diameter measurements between volume CT angiography and 3D DSA; no statistical difference in the mean maximum diameter of each aneurysm was measured between volume CT angiography and 3D DSA. L-VCTA is helpful in detecting intracranial aneurysms, with results similar to those of 3D DSA, but at a lower radiation dose than C-VCTA. Copyright © 2012 AUR. Published by Elsevier Inc. All rights reserved.

  1. Fabrication of flexible gold nanorods polymer metafilm via phase transfer method as SERS substrate for detecting food contaminants.

    PubMed

    Yang, Nan; You, Ting-Ting; Gao, Yu-Kun; Zhang, Chen-Meng; Yin, Penggang

    2018-06-08

    Surface enhanced Raman scattering (SERS) has been widely used in detection of food safety due to the nondestructive examination property. Here, we reported a flexible SERS film based on polymer immobilized gold nanorods polymer metafilm. Polystyrene-polyisoprene-polystyrene (SIS), a transparent and flexible along with excellent elasticity polymer was chosen as main support of gold nanorods. A simple phase transfer progress was adopted to mix the gold nanorods with polymer which can further used in most water-insoluble polymers. The SERS film performed satisfactorily while tested in a series of standard Raman probes like crystal violet (CV) and malachite green (MG). Moreover, the excellent reproducibility and elastic properties make the film promising substrates in practical detection. Hence, the MG detection on fish surface and trace thiram detection on orange pericarp were inspected with the detection result of 1 × 10-10 M and 1 × 10-6 M which below the demand of National standard of China, exactly matching the realistic application requirements.

  2. Clusters of Monoisotopic Elements for Calibration in (TOF) Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Kolářová, Lenka; Prokeš, Lubomír; Kučera, Lukáš; Hampl, Aleš; Peňa-Méndez, Eladia; Vaňhara, Petr; Havel, Josef

    2017-03-01

    Precise calibration in TOF MS requires suitable and reliable standards, which are not always available for high masses. We evaluated inorganic clusters of the monoisotopic elements gold and phosphorus (Au n +/Au n - and P n +/P n -) as an alternative to peptides or proteins for the external and internal calibration of mass spectra in various experimental and instrumental scenarios. Monoisotopic gold or phosphorus clusters can be easily generated in situ from suitable precursors by laser desorption/ionization (LDI) or matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). Their use offers numerous advantages, including simplicity of preparation, biological inertness, and exact mass determination even at lower mass resolution. We used citrate-stabilized gold nanoparticles to generate gold calibration clusters, and red phosphorus powder to generate phosphorus clusters. Both elements can be added to samples to perform internal calibration up to mass-to-charge ( m/z) 10-15,000 without significantly interfering with the analyte. We demonstrated the use of the gold and phosphorous clusters in the MS analysis of complex biological samples, including microbial standards and total extracts of mouse embryonic fibroblasts. We believe that clusters of monoisotopic elements could be used as generally applicable calibrants for complex biological samples.

  3. Comparison of the gold standard of hemoglobin measurement with the clinical standard (BGA) and noninvasive hemoglobin measurement (SpHb) in small children: a prospective diagnostic observational study.

    PubMed

    Wittenmeier, Eva; Bellosevich, Sophia; Mauff, Susanne; Schmidtmann, Irene; Eli, Michael; Pestel, Gunther; Noppens, Ruediger R

    2015-10-01

    Collecting a blood sample is usually necessary to measure hemoglobin levels in children. Especially in small children, noninvasively measuring the hemoglobin level could be extraordinarily helpful, but its precision and accuracy in the clinical environment remain unclear. In this study, noninvasive hemoglobin measurement and blood gas analysis were compared to hemoglobin measurement in a clinical laboratory. In 60 healthy preoperative children (0.2-7.6 years old), hemoglobin was measured using a noninvasive method (SpHb; Radical-7 Pulse Co-Oximeter), a blood gas analyzer (clinical standard, BGAHb; ABL 800 Flex), and a laboratory hematology analyzer (reference method, labHb; Siemens Advia). Agreement between the results was assessed by Bland-Altman analysis and by determining the percentage of outliers. Sixty SpHb measurements, 60 labHb measurements, and 59 BGAHb measurements were evaluated. In 38% of the children, the location of the SpHb sensor had to be changed more than twice for the signal quality to be sufficient. The bias/limits of agreement between SpHb and labHb were -0.65/-3.4 to 2.1 g·dl(-1) . Forty-four percent of the SpHb values differed from the reference value by more than 1 g·dl(-1) . Age, difficulty of measurement, and the perfusion index (PI) had no influence on the accuracy of SpHb. The bias/limits of agreement between BGAHb and labHb were 1.14/-1.6 to 3.9 g·dl(-1) . Furthermore, 66% of the BGAHb values differed from the reference values by more than 1 g·dl(-1) . The absolute mean difference between SpHb and labHb (1.1 g·dl(-1) ) was smaller than the absolute mean difference between BGAHb and labHb (1.5 g·dl(-1) /P = 0.024). Noninvasive measurement of hemoglobin agrees more with the reference method than the measurement of hemoglobin using a blood gas analyzer. However, both methods can show clinically relevant differences from the reference method (ClinicalTrials.gov: NCT01693016). © 2015 John Wiley & Sons Ltd.

  4. An Evaluation of Portable Wet Bulb Globe Temperature Monitor Accuracy.

    PubMed

    Cooper, Earl; Grundstein, Andrew; Rosen, Adam; Miles, Jessica; Ko, Jupil; Curry, Patrick

    2017-12-01

      Wet bulb globe temperature (WBGT) is the gold standard for assessing environmental heat stress during physical activity. Many manufacturers of commercially available instruments fail to report WBGT accuracy.   To determine the accuracy of several commercially available WBGT monitors compared with a standardized reference device.   Observational study.   Field test.   Six commercially available WBGT devices.   Data were recorded for 3 sessions (1 in the morning and 2 in the afternoon) at 2-minute intervals for at least 2 hours. Mean absolute error (MAE), root mean square error (RMSE), mean bias error (MBE), and the Pearson correlation coefficient ( r) were calculated to determine instrument performance compared with the reference unit.   The QUESTemp° 34 (MAE = 0.24°C, RMSE = 0.44°C, MBE = -0.64%) and Extech HT30 Heat Stress Wet Bulb Globe Temperature Meter (Extech; MAE = 0.61°C, RMSE = 0.79°C, MBE = 0.44%) demonstrated the least error in relation to the reference standard, whereas the General WBGT8778 Heat Index Checker (General; MAE = 1.18°C, RMSE = 1.34°C, MBE = 4.25%) performed the poorest. The QUESTemp° 34 and Kestrel 4400 Heat Stress Tracker units provided conservative measurements that slightly overestimated the WBGT provided by the reference unit. Finally, instruments using the psychrometric wet bulb temperature (General, REED Heat Index WBGT Meter, and WBGT-103 Heat Stroke Checker) tended to underestimate the WBGT, and the resulting values more frequently fell into WBGT-based activity categories with fewer restrictions as defined by the American College of Sports Medicine.   The QUESTemp° 34, followed by the Extech, had the smallest error compared with the reference unit. Moreover, the QUESTemp° 34, Extech, and Kestrel units appeared to offer conservative yet accurate assessments of the WBGT, potentially minimizing the risk of allowing physical activity to continue in stressful heat environments. Instruments using the psychrometric wet bulb temperature tended to underestimate WBGT under low wind-speed conditions. Accurate WBGT interpretations are important to enable clinicians to guide activities in hot and humid weather conditions.

  5. Gel Electrophoresis of Gold-DNA Nanoconjugates

    DOE PAGES

    Pellegrino, T.; Sperling, R. A.; Alivisatos, A. P.; ...

    2007-01-01

    Gold-DNA conjugates were investigated in detail by a comprehensive gel electrophoresis study based on 1200 gels. A controlled number of single-stranded DNA of different length was attached specifically via thiol-Au bonds to phosphine-stabilized colloidal gold nanoparticles. Alternatively, the surface of the gold particles was saturated with single stranded DNA of different length either specifically via thiol-Au bonds or by nonspecific adsorption. From the experimentally determined electrophoretic mobilities, estimates for the effective diameters of the gold-DNA conjugates were derived by applying two different data treatment approaches. The first method is based on making a calibration curve for the relation between effectivemore » diameters and mobilities with gold nanoparticles of known diameter. The second method is based on Ferguson analysis which uses gold nanoparticles of known diameter as reference database. Our study shows that effective diameters derived from gel electrophoresis measurements are affected with a high error bar as the determined values strongly depend on the method of evaluation, though relative changes in size upon binding of molecules can be detected with high precision. Furthermore, in this study, the specific attachment of DNA via gold-thiol bonds to Au nanoparticles is compared to nonspecific adsorption of DNA. Also, the maximum number of DNA molecules that can be bound per particle was determined.« less

  6. Imaging evaluation of non-alcoholic fatty liver disease: focused on quantification.

    PubMed

    Lee, Dong Ho

    2017-12-01

    Non-alcoholic fatty liver disease (NAFLD) has been an emerging major health problem, and the most common cause of chronic liver disease in Western countries. Traditionally, liver biopsy has been gold standard method for quantification of hepatic steatosis. However, its invasive nature with potential complication as well as measurement variability are major problem. Thus, various imaging studies have been used for evaluation of hepatic steatosis. Ultrasonography provides fairly good accuracy to detect moderate-to-severe degree hepatic steatosis, but limited accuracy for mild steatosis. Operator-dependency and subjective/qualitative nature of examination are another major drawbacks of ultrasonography. Computed tomography can be considered as an unsuitable imaging modality for evaluation of NAFLD due to potential risk of radiation exposure and limited accuracy in detecting mild steatosis. Both magnetic resonance spectroscopy and magnetic resonance imaging using chemical shift technique provide highly accurate and reproducible diagnostic performance for evaluating NAFLD, and therefore, have been used in many clinical trials as a non-invasive reference of standard method.

  7. Fractional flow reserve guided revascularization in daily practice: clinical judgment does not always meet science.

    PubMed

    Rubinshtein, Ronen; Jaffe, Ronen

    2013-09-01

    Measurement of the fractional flow reserve (FFR) during invasive coronary angiography is the accepted ''gold standard'' for assessing the functional significance of coronary artery lesions by determination of the characteristics of blood flow proximal and distal to a coronary stenosis during pharmacologically-mediated hyperemia. Abnormal FFR is associated with higher cardiac event rate if the coronary lesion is left untreated. On the other hand, it was shown that patients derived no clinical benefit from revascularization of angiographically obstructive lesions which were hemodynamically insignificant according to FFR (>0.8). This editorial comment refers to an observational cohort study which reported that in approximately 20% of real world patients the treatment strategy chosen was discordant with FFR findings. Our comment discusses these findings and concludes that while the standard of care is to treat patients in accordance with their FFR results (when available), it should be recognized that there are some clinical scenarios that may require a treatment strategy that is discordant with FFR result.

  8. Imaging evaluation of non-alcoholic fatty liver disease: focused on quantification

    PubMed Central

    2017-01-01

    Non-alcoholic fatty liver disease (NAFLD) has been an emerging major health problem, and the most common cause of chronic liver disease in Western countries. Traditionally, liver biopsy has been gold standard method for quantification of hepatic steatosis. However, its invasive nature with potential complication as well as measurement variability are major problem. Thus, various imaging studies have been used for evaluation of hepatic steatosis. Ultrasonography provides fairly good accuracy to detect moderate-to-severe degree hepatic steatosis, but limited accuracy for mild steatosis. Operator-dependency and subjective/qualitative nature of examination are another major drawbacks of ultrasonography. Computed tomography can be considered as an unsuitable imaging modality for evaluation of NAFLD due to potential risk of radiation exposure and limited accuracy in detecting mild steatosis. Both magnetic resonance spectroscopy and magnetic resonance imaging using chemical shift technique provide highly accurate and reproducible diagnostic performance for evaluating NAFLD, and therefore, have been used in many clinical trials as a non-invasive reference of standard method. PMID:28994271

  9. Treat-to-target trials in diabetes.

    PubMed

    Wangnoo, Subhash K; Sethi, Bipin; Sahay, Rakesh K; John, Mathew; Ghosal, Samit; Sharma, Surendra K

    2014-03-01

    Treat-to-target is a therapeutic concept that considers well defined and specific physiologic targets as aims in controlling the pathophysiology of the disease. It has been widely used in diseases that pathophysiology includes, chronic metabolic and physiological disturbances, namely rheumatic conditions, vascular medicine and diabetes. In diabetes, the availability of "gold-standard" quantitative measures like fasting plasma glucose and glycated hemoglobin make the application of treat-to-target trials especially pertinent. Treatment modalities which have used single therapeutic agents or combinations or in combination with a variety of titration algorithms and implementation protocols have broadened our understanding of diabetes management with specific reference to insulin initiation and maintenance. Treat-to-target trials have been used to investigate a wide variety of questions including efficacy, safety, effect of treatment on comorbidities and patient satisfaction, ideal mechanisms to implement insulin initiation etc. A more generalized acceptance and implementation of treat-to-target trials may finally revolutionize diabetes management by combining aspects of individual care with standard treatment protocols.

  10. Terminalia chebula mediated green and rapid synthesis of gold nanoparticles

    NASA Astrophysics Data System (ADS)

    Mohan Kumar, Kesarla; Mandal, Badal Kumar; Sinha, Madhulika; Krishnakumar, Varadhan

    2012-02-01

    Biologically inspired experimental process in synthesising nanoparticles is of great interest in present scenario. Biosynthesis of nanoparticles is considered to be one of the best green techniques in synthesising metal nanoparticles. Here, an in situ green biogenic synthesis of gold nanoparticles using aqueous extracts of Terminalia chebula as reducing and stabilizing agent is reported. Gold nanoparticles were confirmed by surface plasmon resonance in the range of 535 nm using UV-visible spectrometry. TEM analysis revealed that the morphology of the particles thus formed contains anisotropic gold nanoparticles with size ranging from 6 to 60 nm. Hydrolysable tannins present in the extract of T. chebula are responsible for reductions and stabilization of gold nanoparticles. Antimicrobial activity of gold nanoparticles showed better activity towards gram positive S. aureus compared to gram negative E. coli using standard well diffusion method.

  11. Extractive photometric determination of gold(III) with 1-(2',4',6'-trichlorophenyl)-4,4,6-trimethyl-(1H,4H)-2-pyrimidinethiol in presence of tri-iso-octylamine.

    PubMed

    Amuse, M A; Kuchekar, S R; Mote, N A; Chavan, M B

    1985-10-01

    Tervalent gold was determined spectrophotometrically as its anionic 1:4 gold-thiol complex extracted into chloroform from aqueous acidic medium (1.5M sulphuric acid) in the presence of tri-iso-octylamine. The complex exhibits maximum absorption at 480 nm (molar absorptivity 4.60 x 10(3) l.mole(-1).cm(-1)) and Beer's law is obeyed in the concentration range 5-50 microg of gold(III) per ml. The relative standard deviation and relative error, calculated from ten determinations of solutions containing 15 microg of gold(III) per ml were 1.0% and 0.8%. The method is simple, selective and reproducible. It permits separation of gold(III) from associated elements and its determination in synthetic mixtures.

  12. Tessellated gold nanostructures from Au144(SCH2CH2Ph)60 molecular precursors and their use in organic solar cell enhancement

    NASA Astrophysics Data System (ADS)

    Bauld, Reg; Hesari, Mahdi; Workentin, Mark S.; Fanchini, Giovanni

    2014-06-01

    We report for the first time the fabrication of nanocomposite hole-blocking layers consisting of poly-3,4-ethylene-dioxythiophene:poly-styrene-sulfonate (PEDOT:PSS) thin films incorporating networks of gold nanoparticles assembled from Au144(SCH2CH2Ph)60, a molecular gold precursor. These thin films can be prepared reproducibly on indium tin oxide by spinning on it Au144(SCH2CH2Ph)60 solutions in chlorobenzene, annealing the resulting thin film at 400 °C, and subsequently spinning PEDOT:PSS on top. The use of our nanocomposite hole-blocking layers for enhancing the photoconversion efficiency of bulk heterojunction organic solar cells is demonstrated. By varying the concentration of Au144(SCH2CH2Ph)60 in the starting solution and the annealing time, different gold nanostructures were obtained ranging from individual gold nanoparticles (AuNPs) to tessellated networks of gold nanostructures (Tess-AuNPs). Improvement in organic solar cell efficiencies up to 10% relative to a reference cell is demonstrated with Tess-AuNPs embedded in PEDOT:PSS.

  13. Pulse-voltammetric glucose detection at gold junction electrodes.

    PubMed

    Rassaei, Liza; Marken, Frank

    2010-09-01

    A novel glucose sensing concept based on the localized change or "modulation" in pH within a symmetric gold-gold junction electrode is proposed. A paired gold-gold junction electrode (average gap size ca. 500 nm) is prepared by simultaneous bipotentiostatic electrodeposition of gold onto two closely spaced platinum disk electrodes. For glucose detection in neutral aqueous solution, the potential of the "pH-modulator" electrode is set to -1.5 V vs saturated calomel reference electrode (SCE) to locally increase the pH, and simultaneously, either cyclic voltammetry or square wave voltammetry experiments are conducted at the sensor electrode. A considerable improvement in the sensor electrode response is observed when a normal pulse voltammetry sequence is applied to the modulator electrode (to generate "hydroxide pulses") and the glucose sensor electrode is operated with fixed bias at +0.5 V vs SCE (to eliminate capacitive charging currents). Preliminary data suggest good linearity for the glucose response in the medically relevant 1-10 mM concentration range (corresponding to 0.18-1.8 g L(-1)). Future electroanalytical applications of multidimensional pulse voltammetry in junction electrodes are discussed.

  14. Patterning of oxide-hardened gold black by photolithography and metal lift-off

    NASA Astrophysics Data System (ADS)

    Panjwani, Deep; Yesiltas, Mehmet; Nath, Janardan; Maukonen, D. E.; Rezadad, Imen; Smith, Evan M.; Peale, R. E.; Hirschmugl, Carol; Sedlmair, Julia; Wehlitz, Ralf; Unger, Miriam; Boreman, Glenn

    2014-01-01

    A method to pattern infrared-absorbing gold black by conventional photolithography and lift-off is described. A photo-resist pattern is developed on a substrate by standard photolithography. Gold black is deposited over the whole by thermal evaporation in an inert gas at ˜1 Torr. SiO2 is then deposited as a protection layer by electron beam evaporation. Lift-off proceeds by dissolving the photoresist in acetone. The resulting sub-millimeter size gold black patterns that remain on the substrate retain high infrared absorption out to ˜5 μm wavelength and exhibit good mechanical stability. This technique allows selective application of gold black coatings to the pixels of thermal infrared imaging array detectors.

  15. ASSESSING AND COMBINING RELIABILITY OF PROTEIN INTERACTION SOURCES

    PubMed Central

    LEACH, SONIA; GABOW, AARON; HUNTER, LAWRENCE; GOLDBERG, DEBRA S.

    2008-01-01

    Integrating diverse sources of interaction information to create protein networks requires strategies sensitive to differences in accuracy and coverage of each source. Previous integration approaches calculate reliabilities of protein interaction information sources based on congruity to a designated ‘gold standard.’ In this paper, we provide a comparison of the two most popular existing approaches and propose a novel alternative for assessing reliabilities which does not require a gold standard. We identify a new method for combining the resultant reliabilities and compare it against an existing method. Further, we propose an extrinsic approach to evaluation of reliability estimates, considering their influence on the downstream tasks of inferring protein function and learning regulatory networks from expression data. Results using this evaluation method show 1) our method for reliability estimation is an attractive alternative to those requiring a gold standard and 2) the new method for combining reliabilities is less sensitive to noise in reliability assignments than the similar existing technique. PMID:17990508

  16. Decision Making in the Management of Extracapsular Fractures of the Proximal Femur - is the Dynamic Hip Screw the Prevailing Gold Standard?

    PubMed

    Jacob, Joshua; Desai, Ankit; Trompeter, Alex

    2017-01-01

    Currently, approximately half of all hip fractures are extracapsular, with an incidence as high as 50 in 100,000 in some countries. The common classification systems fail to explain the logistics of fracture classification and whether they all behave in the same manner. The Muller AO classification system is a useful platform to delineate stable and unstable fractures. The Dynamic hip screw (DHS) however, has remained the 'gold standard' implant of choice for application in all extracapsular fractures. The DHS relies on the integrity and strength of the lateral femoral wall as well as the postero-medial fragment. An analysis of several studies indicates significant improvements in design and techniques to ensure a better outcome with intramedullary nails. This article reviews the historical trends that helped to evolve the DHS implant as well as discussing if the surgeon should remain content with this implant. We suggest that the gold standard surgical management of extracapsular fractures can, and should, evolve.

  17. Evaluation of diagnostic accuracy in detecting ordered symptom statuses without a gold standard

    PubMed Central

    Wang, Zheyu; Zhou, Xiao-Hua; Wang, Miqu

    2011-01-01

    Our research is motivated by 2 methodological problems in assessing diagnostic accuracy of traditional Chinese medicine (TCM) doctors in detecting a particular symptom whose true status has an ordinal scale and is unknown—imperfect gold standard bias and ordinal scale symptom status. In this paper, we proposed a nonparametric maximum likelihood method for estimating and comparing the accuracy of different doctors in detecting a particular symptom without a gold standard when the true symptom status had an ordered multiple class. In addition, we extended the concept of the area under the receiver operating characteristic curve to a hyper-dimensional overall accuracy for diagnostic accuracy and alternative graphs for displaying a visual result. The simulation studies showed that the proposed method had good performance in terms of bias and mean squared error. Finally, we applied our method to our motivating example on assessing the diagnostic abilities of 5 TCM doctors in detecting symptoms related to Chills disease. PMID:21209155

  18. Diagnostic Accuracy of Periapical Radiography and Cone-beam Computed Tomography in Identifying Root Canal Configuration of Human Premolars.

    PubMed

    Sousa, Thiago Oliveira; Haiter-Neto, Francisco; Nascimento, Eduarda Helena Leandro; Peroni, Leonardo Vieira; Freitas, Deborah Queiroz; Hassan, Bassam

    2017-07-01

    The aim of this study was to assess the diagnostic accuracy of periapical radiography (PR) and cone-beam computed tomographic (CBCT) imaging in the detection of the root canal configuration (RCC) of human premolars. PR and CBCT imaging of 114 extracted human premolars were evaluated by 2 oral radiologists. RCC was recorded according to Vertucci's classification. Micro-computed tomographic imaging served as the gold standard to determine RCC. Accuracy, sensitivity, specificity, and predictive values were calculated. The Friedman test compared both PR and CBCT imaging with the gold standard. CBCT imaging showed higher values for all diagnostic tests compared with PR. Accuracy was 0.55 and 0.89 for PR and CBCT imaging, respectively. There was no difference between CBCT imaging and the gold standard, whereas PR differed from both CBCT and micro-computed tomographic imaging (P < .0001). CBCT imaging was more accurate than PR for evaluating different types of RCC individually. Canal configuration types III, VII, and "other" were poorly identified on CBCT imaging with a detection accuracy of 50%, 0%, and 43%, respectively. With PR, all canal configurations except type I were poorly visible. PR presented low performance in the detection of RCC in premolars, whereas CBCT imaging showed no difference compared with the gold standard. Canals with complex configurations were less identifiable using both imaging methods, especially PR. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  19. Parameter estimation in Cox models with missing failure indicators and the OPPERA study.

    PubMed

    Brownstein, Naomi C; Cai, Jianwen; Slade, Gary D; Bair, Eric

    2015-12-30

    In a prospective cohort study, examining all participants for incidence of the condition of interest may be prohibitively expensive. For example, the "gold standard" for diagnosing temporomandibular disorder (TMD) is a physical examination by a trained clinician. In large studies, examining all participants in this manner is infeasible. Instead, it is common to use questionnaires to screen for incidence of TMD and perform the "gold standard" examination only on participants who screen positively. Unfortunately, some participants may leave the study before receiving the "gold standard" examination. Within the framework of survival analysis, this results in missing failure indicators. Motivated by the Orofacial Pain: Prospective Evaluation and Risk Assessment (OPPERA) study, a large cohort study of TMD, we propose a method for parameter estimation in survival models with missing failure indicators. We estimate the probability of being an incident case for those lacking a "gold standard" examination using logistic regression. These estimated probabilities are used to generate multiple imputations of case status for each missing examination that are combined with observed data in appropriate regression models. The variance introduced by the procedure is estimated using multiple imputation. The method can be used to estimate both regression coefficients in Cox proportional hazard models as well as incidence rates using Poisson regression. We simulate data with missing failure indicators and show that our method performs as well as or better than competing methods. Finally, we apply the proposed method to data from the OPPERA study. Copyright © 2015 John Wiley & Sons, Ltd.

  20. Accuracy of visual assessments of proliferation indices in gastroenteropancreatic neuroendocrine tumours.

    PubMed

    Young, Helen T M; Carr, Norman J; Green, Bryan; Tilley, Charles; Bhargava, Vidhi; Pearce, Neil

    2013-08-01

    To compare the accuracy of eyeball estimates of the Ki-67 proliferation index (PI) with formal counting of 2000 cells as recommend by the Royal College of Pathologists. Sections from gastroenteropancreatic neuroendocrine tumours were immunostained for Ki-67. PI was calculated using three methods: (1) a manual tally count of 2000 cells from the area of highest nuclear labelling using a microscope eyepiece graticule; (2) eyeball estimates made by four pathologists within the same area of highest nuclear labelling; and (3) image analysis of microscope photographs taken from this area using the ImageJ 'cell counter' tool. ImageJ analysis was considered the gold standard for comparison. Levels of agreement between methods were evaluated using Bland-Altman plots. Agreement between the manual tally and ImageJ assessments was very high at low PIs. Agreement between eyeball assessments and ImageJ analysis varied between pathologists. Where data for low PIs alone were analysed, there was a moderate level of agreement between pathologists' estimates and the gold standard, but when all data were included, agreement was poor. Manual tally counts of 2000 cells exhibited similar levels of accuracy to the gold standard, especially at low PIs. Eyeball estimates were significantly less accurate than the gold standard. This suggests that tumour grades may be misclassified by eyeballing and that formal tally counting of positive cells produces more reliable results. Further studies are needed to identify accurate clinically appropriate ways of calculating.

  1. Vertical bone measurements from cone beam computed tomography images using different software packages.

    PubMed

    Vasconcelos, Taruska Ventorini; Neves, Frederico Sampaio; Moraes, Lívia Almeida Bueno; Freitas, Deborah Queiroz

    2015-01-01

    This article aimed at comparing the accuracy of linear measurement tools of different commercial software packages. Eight fully edentulous dry mandibles were selected for this study. Incisor, canine, premolar, first molar and second molar regions were selected. Cone beam computed tomography (CBCT) images were obtained with i-CAT Next Generation. Linear bone measurements were performed by one observer on the cross-sectional images using three different software packages: XoranCat®, OnDemand3D® and KDIS3D®, all able to assess DICOM images. In addition, 25% of the sample was reevaluated for the purpose of reproducibility. The mandibles were sectioned to obtain the gold standard for each region. Intraclass coefficients (ICC) were calculated to examine the agreement between the two periods of evaluation; the one-way analysis of variance performed with the post-hoc Dunnett test was used to compare each of the software-derived measurements with the gold standard. The ICC values were excellent for all software packages. The least difference between the software-derived measurements and the gold standard was obtained with the OnDemand3D and KDIS3D (-0.11 and -0.14 mm, respectively), and the greatest, with the XoranCAT (+0.25 mm). However, there was no statistical significant difference between the measurements obtained with the different software packages and the gold standard (p> 0.05). In conclusion, linear bone measurements were not influenced by the software package used to reconstruct the image from CBCT DICOM data.

  2. Validation of a Magnetic Resonance Imaging-based Auto-contouring Software Tool for Gross Tumour Delineation in Head and Neck Cancer Radiotherapy Planning.

    PubMed

    Doshi, T; Wilson, C; Paterson, C; Lamb, C; James, A; MacKenzie, K; Soraghan, J; Petropoulakis, L; Di Caterina, G; Grose, D

    2017-01-01

    To carry out statistical validation of a newly developed magnetic resonance imaging (MRI) auto-contouring software tool for gross tumour volume (GTV) delineation in head and neck tumours to assist in radiotherapy planning. Axial MRI baseline scans were obtained for 10 oropharyngeal and laryngeal cancer patients. GTV was present on 102 axial slices and auto-contoured using the modified fuzzy c-means clustering integrated with the level set method (FCLSM). Peer-reviewed (C-gold) manual contours were used as the reference standard to validate auto-contoured GTVs (C-auto) and mean manual contours (C-manual) from two expert clinicians (C1 and C2). Multiple geometric metrics, including the Dice similarity coefficient (DSC), were used for quantitative validation. A DSC≥0.7 was deemed acceptable. Inter- and intra-variabilities among the manual contours were also validated. The two-dimensional contours were then reconstructed in three dimensions for GTV volume calculation, comparison and three-dimensional visualisation. The mean DSC between C-gold and C-auto was 0.79. The mean DSC between C-gold and C-manual was 0.79 and that between C1 and C2 was 0.80. The average time for GTV auto-contouring per patient was 8 min (range 6-13 min; mean 45 s per axial slice) compared with 15 min (range 6-23 min; mean 88 s per axial slice) for C1. The average volume concordance between C-gold and C-auto volumes was 86.51% compared with 74.16% between C-gold and C-manual. The average volume concordance between C1 and C2 volumes was 86.82%. This newly designed MRI-based auto-contouring software tool shows initial acceptable results in GTV delineation of oropharyngeal and laryngeal tumours using FCLSM. This auto-contouring software tool may help reduce inter- and intra-variability and can assist clinical oncologists with time-consuming, complex radiotherapy planning. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  3. Electroanalytical sensing of chromium(III) and (VI) utilising gold screen printed macro electrodes.

    PubMed

    Metters, Jonathan P; Kadara, Rashid O; Banks, Craig E

    2012-02-21

    We report the fabrication of gold screen printed macro electrodes which are electrochemically characterised and contrasted to polycrystalline gold macroelectrodes with their potential analytical application towards the sensing of chromium(III) and (VI) critically explored. It is found that while these gold screen printed macro electrodes have electrode kinetics typically one order of magnitude lower than polycrystalline gold macroelectrodes as is measured via a standard redox probe, in terms of analytical sensing, these gold screen printed macro electrodes mimic polycrystalline gold in terms of their analytical performance towards the sensing of chromium(III) and (VI), whilst boasting additional advantages over the macro electrode due to their disposable one-shot nature and the ease of mass production. An additional advantage of these gold screen printed macro electrodes compared to polycrystalline gold is the alleviation of the requirement to potential cycle the latter to form the required gold oxide which aids in the simplification of the analytical protocol. We demonstrate that gold screen printed macro electrodes allow the low micro-molar sensing of chromium(VI) in aqueous solutions over the range 10 to 1600 μM with a limit of detection (3σ) of 4.4 μM. The feasibility of the analytical protocol is also tested through chromium(VI) detection in environmental samples.

  4. Molecular Simulations of The Formation of Gold-Molecule-Gold Junctions

    NASA Astrophysics Data System (ADS)

    Wang, Huachuan

    2013-03-01

    We perform classical molecular simulations by combining grand canonical Monte Carlo (GCMC) sampling with molecular dynamics (MD) simulation to explore the dynamic gold nanojunctions in a Alkenedithiol (ADT) solvent. With the aid of a simple driving-spring model, which can reasonably represent the long-range elasticity of the gold electrode, the spring forces are obtained during the dynamic stretching procedure. A specific multi-time-scale double reversible reference system propagator (double-RESPA) algorithm has been designed for the metal-organic complex in MD simulations to identify the detailed metal-molecule bonding geometry at metal-molecule-metal interface. We investigate the variations of bonding sites of ADT molecules on gold nanojunctions at Au (111) surface at a constant chemical potential. Simulation results show that an Au-ADT-Au interface is formed on Au nanojunctions, bond-breaking intersection is at 1-1 bond of the monatomic chain of the cross-section, instead of at the Au-S bond. Breaking force is around 1.5 nN. These are consistent with the experimental measurements.

  5. Mapping Hydrothermal Alterations in the Muteh Gold Mining Area in Iran by using ASTER satellite Imagery data

    NASA Astrophysics Data System (ADS)

    Asadi Haroni, Hooshang; Hassan Tabatabaei, Seyed

    2016-04-01

    Muteh gold mining area is located in 160 km NW of Isfahan town. Gold mineralization is meso-thermal type and associated with silisic, seresitic and carbonate alterations as well as with hematite and goethite. Image processing and interpretation were applied on the ASTER satellite imagery data of about 400 km2 at the Muteh gold mining area to identify hydrothermal alterations and iron oxides associated with gold mineralization. After applying preprocessing methods such as radiometric and geometric corrections, image processing methods of Principal Components Analysis (PCA), Least Square Fit (Ls-Fit) and Spectral Angle Mapper (SAM) were applied on the ASTER data to identify hydrothermal alterations and iron oxides. In this research reference spectra of minerals such as chlorite, hematite, clay minerals and phengite identified from laboratory spectral analysis of collected samples were used to map the hydrothermal alterations. Finally, identified hydrothermal alteration and iron oxides were validated by visiting and sampling some of the mapped hydrothermal alterations.

  6. Oxygen isotope exchange with quartz during pyrolysis of silver sulfate and silver nitrate.

    PubMed

    Schauer, Andrew J; Kunasek, Shelley A; Sofen, Eric D; Erbland, Joseph; Savarino, Joel; Johnson, Ben W; Amos, Helen M; Shaheen, Robina; Abaunza, Mariana; Jackson, Terri L; Thiemens, Mark H; Alexander, Becky

    2012-09-30

    Triple oxygen isotopes of sulfate and nitrate are useful metrics for the chemistry of their formation. Existing measurement methods, however, do not account for oxygen atom exchange with quartz during the thermal decomposition of sulfate. We present evidence for oxygen atom exchange, a simple modification to prevent exchange, and a correction for previous measurements. Silver sulfates and silver nitrates with excess (17)O were thermally decomposed in quartz and gold (for sulfate) and quartz and silver (for nitrate) sample containers to O(2) and byproducts in a modified Temperature Conversion/Elemental Analyzer (TC/EA). Helium carries O(2) through purification for isotope-ratio analysis of the three isotopes of oxygen in a Finnigan MAT253 isotope ratio mass spectrometer. The Δ(17)O results show clear oxygen atom exchange from non-zero (17)O-excess reference materials to zero (17)O-excess quartz cup sample containers. Quartz sample containers lower the Δ(17)O values of designer sulfate reference materials and USGS35 nitrate by 15% relative to gold or silver sample containers for quantities of 2-10 µmol O(2). Previous Δ(17)O measurements of sulfate that rely on pyrolysis in a quartz cup have been affected by oxygen exchange. These previous results can be corrected using a simple linear equation (Δ(17)O(gold) = Δ(17)O(quartz) * 1.14 + 0.06). Future pyrolysis of silver sulfate should be conducted in gold capsules or corrected to data obtained from gold capsules to avoid obtaining oxygen isotope exchange-affected data. Copyright © 2012 John Wiley & Sons, Ltd.

  7. A novel 'Gold on Gold' biosensing scheme for an on-fiber immunoassay

    NASA Astrophysics Data System (ADS)

    Punjabi, N.; Satija, J.; Mukherji, S.

    2015-05-01

    In this paper, we propose a novel „gold on gold‟ biosensing scheme for absorbance based fiber-optic biosensor. First, a self-assembled monolayer of gold nanoparticles is formed at the sensing region of the fiber-optic probe by incubating an amino-silanized probe in a colloidal gold solution. Thereafter, the receptor moieties, i.e. Human immunoglobulin G (HIgG) were immobilized by using standard alkanethiol and classic carbodiimide coupling chemistry. Finally, biosensing experiments were performed with different concentrations of gold nanoparticle-tagged analyte, i.e. Goat anti- Human immunoglobulin G (Nanogold-GaHIgG). The sensor response was observed to be more than five-fold compared to the control bioassay, in which the sensor matrix was devoid of gold nanoparticle film. Also, the response was found to be ~10 times higher compared to the FITC-tagged scheme and ~14.5 times better compared to untagged scheme. This novel scheme also demonstrated the potential in improving the limit of detection for the fiber-optic biosensors.

  8. Hodgkin Lymphoma revealed by epidural spinal cord compression.

    PubMed

    Ghedira, Khalil; Matar, Nidhal; Bouali, Sofiene; Zehani, Alia; Boubaker, Adnen; Jemel, Hafedh

    2018-01-30

    Hodgkin Lymphoma is rarely diagnosed as spinal cord compression syndrome. Caused by an epidural mass, this complication is often encountered in a late stage of the disease. We report the case of a 40-year-old man presenting with symptoms of low thoracic spinal cord compression due to an epidural tumor on the MRI. Emergent surgery was undertaken on this patient, consisting in laminectomy and tumor resection. After surgery, pain relief and mild neurological improvement were noticed. The histological study revealed a Hodgkin Lymphoma and the patient was referred to chemotherapy and radiotherapy. Though chemotherapy is the gold standard treatment for Hodgkin Lymphoma, surgical spinal decompression may be required in epidural involvement of the disease. Diagnosis may be suspected in the presence of lymphadenopathy and general health decay.

  9. Endobronchial cryotherapy facilitates end-stage treatment options in patients with bronchial stenosis: A case series

    PubMed Central

    Fitzmaurice, Gerard J.; Redmond, Karen C.; Fitzpatrick, David A.; Bartosik, Waldemar

    2014-01-01

    In keeping with international trends, lung cancer incidence and mortality are increasing among the Irish population with many patients presenting with advanced disease that excludes the potential for curative management. Consequently palliative treatment options for this patient group are being increasingly explored with various degrees of success. Endobronchial stenosis represents a particularly challenging area of management among these patients and a number of techniques have been described without the identification of a single gold standard. We report our experience of the first time use of endobronchial cryotherapy in Ireland with reference to a case series, including an example of its use in the management of benign disease, in order to support patients with borderline lung function and enable definitive palliative treatment. PMID:24791176

  10. Validation conform ISO-15189 of assays in the field of autoimmunity: Joint efforts in The Netherlands.

    PubMed

    Mulder, Leontine; van der Molen, Renate; Koelman, Carin; van Leeuwen, Ester; Roos, Anja; Damoiseaux, Jan

    2018-05-01

    ISO 15189:2012 requires validation of methods used in the medical laboratory, and lists a series of performance parameters for consideration to include. Although these performance parameters are feasible for clinical chemistry analytes, application in the validation of autoimmunity tests is a challenge. Lack of gold standards or reference methods in combination with the scarcity of well-defined diagnostic samples of patients with rare diseases make validation of new assays difficult. The present manuscript describes the initiative of Dutch medical immunology laboratory specialists to combine efforts and perform multi-center validation studies of new assays in the field of autoimmunity. Validation data and reports are made available to interested Dutch laboratory specialists. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Integration of gold-sputtered electrofluidic paper on wire-included analytical platforms for glucose biosensing.

    PubMed

    Núnez-Bajo, Estefanía; Carmen Blanco-López, M; Costa-García, Agustín; Teresa Fernández-Abedul, M

    2017-05-15

    This work describes the fabrication and evaluation of an electroanalytical paper-based platform based on the combination of both, reusable and disposable materials in order to generate simple, versatile and low-cost microfluidic devices. With this aim, a holder containing metal wires that act as reusable reference and counter electrodes has been developed. The gold-sputtered paper electrode is disposable and easily interchangeable, meanwhile the platform that includes reference and counter electrodes can be reused. The detection zone in the paper is delimited by drawing a hydrophobic line with an inexpensive permanent marker. The effect of experimental variables such as adding solutions through the face where the gold was sputtered (upwards) or through the opposite one (downwards) as well as of other working parameters were studied by cyclic and differential pulse voltammetry with potassium ferrocyanide as a common redox probe and indicator species for enzymatic, immune and DNA biosensing. Enzymatic determination of glucose in real food samples prove the feasibility of the developed system for the construction of electrochemical biosensors. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. The effect of 3 torque delivery systems on gold screw preload at the gold cylinder-abutment screw joint.

    PubMed

    Tan, Keson B; Nicholls, Jack I

    2002-01-01

    This study measured the gold screw preload at the gold cylinder-abutment screw joint interface obtained by 3 torque delivery systems. Using a precalibrated, strain-gauged standard abutment as the load cell, 3 torque delivery systems tested were shown to have significant differences in gold screw preload when a gold cylinder was attached. Mean preloads measured were 291.2 N for hand torque drivers set at 10 Ncm, 340.3 N for electronic torque controllers at low setting/10 Ncm, 384.4 N for electronic torque controllers at high setting/10 Ncm; and 140.8 N for hand-tightening with a prosthetic slot screwdriver. Significant differences in screw preload were also found between operators using a hand torque driver. Hand-tightening delivered insufficient preload and cannot be recommended for final gold screw tightening. Different electronic torque controller units set at 10 Ncm induced mean gold screw preloads that ranged from 264.1 N to as high as 501.2 N. Electronic torque controllers should be regularly recalibrated to ensure optimal output.

  13. Methods for the guideline-based development of quality indicators--a systematic review

    PubMed Central

    2012-01-01

    Background Quality indicators (QIs) are used in many healthcare settings to measure, compare, and improve quality of care. For the efficient development of high-quality QIs, rigorous, approved, and evidence-based development methods are needed. Clinical practice guidelines are a suitable source to derive QIs from, but no gold standard for guideline-based QI development exists. This review aims to identify, describe, and compare methodological approaches to guideline-based QI development. Methods We systematically searched medical literature databases (Medline, EMBASE, and CINAHL) and grey literature. Two researchers selected publications reporting methodological approaches to guideline-based QI development. In order to describe and compare methodological approaches used in these publications, we extracted detailed information on common steps of guideline-based QI development (topic selection, guideline selection, extraction of recommendations, QI selection, practice test, and implementation) to predesigned extraction tables. Results From 8,697 hits in the database search and several grey literature documents, we selected 48 relevant references. The studies were of heterogeneous type and quality. We found no randomized controlled trial or other studies comparing the ability of different methodological approaches to guideline-based development to generate high-quality QIs. The relevant publications featured a wide variety of methodological approaches to guideline-based QI development, especially regarding guideline selection and extraction of recommendations. Only a few studies reported patient involvement. Conclusions Further research is needed to determine which elements of the methodological approaches identified, described, and compared in this review are best suited to constitute a gold standard for guideline-based QI development. For this research, we provide a comprehensive groundwork. PMID:22436067

  14. Exploring the Use of Sensors to Measure Behavioral Interactions: An Experimental Evaluation of Using Hand Trajectories

    PubMed Central

    Bergmann, Jeroen H. M.; Langdon, Patrick M.; Mayagoitia, Ruth E.; Howard, Newton

    2014-01-01

    Humans appear to be sensitive to relative small changes in their surroundings. These changes are often initially perceived as irrelevant, but they can cause significant changes in behavior. However, how exactly people’s behavior changes is often hard to quantify. A reliable and valid tool is needed in order to address such a question, ideally measuring an important point of interaction, such as the hand. Wearable-body-sensor systems can be used to obtain valuable, behavioral information. These systems are particularly useful for assessing functional interactions that occur between the endpoints of the upper limbs and our surroundings. A new method is explored that consists of computing hand position using a wearable sensor system and validating it against a gold standard reference measurement (optical tracking device). Initial outcomes related well to the gold standard measurements (r = 0.81) showing an acceptable average root mean square error of 0.09 meters. Subsequently, the use of this approach was further investigated by measuring differences in motor behavior, in response to a changing environment. Three subjects were asked to perform a water pouring task with three slightly different containers. Wavelet analysis was introduced to assess how motor consistency was affected by these small environmental changes. Results showed that the behavioral motor adjustments to a variable environment could be assessed by applying wavelet coherence techniques. Applying these procedures in everyday life, combined with correct research methodologies, can assist in quantifying how environmental changes can cause alterations in our motor behavior. PMID:24516583

  15. Statistical method to compare massive parallel sequencing pipelines.

    PubMed

    Elsensohn, M H; Leblay, N; Dimassi, S; Campan-Fournier, A; Labalme, A; Roucher-Boulez, F; Sanlaville, D; Lesca, G; Bardel, C; Roy, P

    2017-03-01

    Today, sequencing is frequently carried out by Massive Parallel Sequencing (MPS) that cuts drastically sequencing time and expenses. Nevertheless, Sanger sequencing remains the main validation method to confirm the presence of variants. The analysis of MPS data involves the development of several bioinformatic tools, academic or commercial. We present here a statistical method to compare MPS pipelines and test it in a comparison between an academic (BWA-GATK) and a commercial pipeline (TMAP-NextGENe®), with and without reference to a gold standard (here, Sanger sequencing), on a panel of 41 genes in 43 epileptic patients. This method used the number of variants to fit log-linear models for pairwise agreements between pipelines. To assess the heterogeneity of the margins and the odds ratios of agreement, four log-linear models were used: a full model, a homogeneous-margin model, a model with single odds ratio for all patients, and a model with single intercept. Then a log-linear mixed model was fitted considering the biological variability as a random effect. Among the 390,339 base-pairs sequenced, TMAP-NextGENe® and BWA-GATK found, on average, 2253.49 and 1857.14 variants (single nucleotide variants and indels), respectively. Against the gold standard, the pipelines had similar sensitivities (63.47% vs. 63.42%) and close but significantly different specificities (99.57% vs. 99.65%; p < 0.001). Same-trend results were obtained when only single nucleotide variants were considered (99.98% specificity and 76.81% sensitivity for both pipelines). The method allows thus pipeline comparison and selection. It is generalizable to all types of MPS data and all pipelines.

  16. Characterizing functional lung heterogeneity in COPD using reference equations for CT scan-measured lobar volumes.

    PubMed

    Come, Carolyn E; Diaz, Alejandro A; Curran-Everett, Douglas; Muralidhar, Nivedita; Hersh, Craig P; Zach, Jordan A; Schroeder, Joyce; Lynch, David A; Celli, Bartolome; Washko, George R

    2013-06-01

    CT scanning is increasingly used to characterize COPD. Although it is possible to obtain CT scan-measured lung lobe volumes, normal ranges remain unknown. Using COPDGene data, we developed reference equations for lobar volumes at maximal inflation (total lung capacity [TLC]) and relaxed exhalation (approximating functional residual capacity [FRC]). Linear regression was used to develop race-specific (non-Hispanic white [NHW], African American) reference equations for lobar volumes. Covariates included height and sex. Models were developed in a derivation cohort of 469 subjects with normal pulmonary function and validated in 546 similar subjects. These cohorts were combined to produce final prediction equations, which were applied to 2,191 subjects with old GOLD (Global Initiative for Chronic Obstructive Lung Disease) stage II to IV COPD. In the derivation cohort, women had smaller lobar volumes than men. Height positively correlated with lobar volumes. Adjusting for height, NHWs had larger total lung and lobar volumes at TLC than African Americans; at FRC, NHWs only had larger lower lobes. Age and weight had no effect on lobar volumes at TLC but had small effects at FRC. In subjects with COPD at TLC, upper lobes exceeded 100% of predicted values in GOLD II disease; lower lobes were only inflated to this degree in subjects with GOLD IV disease. At FRC, gas trapping was severe irrespective of disease severity and appeared uniform across the lobes. Reference equations for lobar volumes may be useful in assessing regional lung dysfunction and how it changes in response to pharmacologic therapies and surgical or endoscopic lung volume reduction.

  17. "Understanding" medical school curriculum content using KnowledgeMap.

    PubMed

    Denny, Joshua C; Smithers, Jeffrey D; Miller, Randolph A; Spickard, Anderson

    2003-01-01

    To describe the development and evaluation of computational tools to identify concepts within medical curricular documents, using information derived from the National Library of Medicine's Unified Medical Language System (UMLS). The long-term goal of the KnowledgeMap (KM) project is to provide faculty and students with an improved ability to develop, review, and integrate components of the medical school curriculum. The KM concept identifier uses lexical resources partially derived from the UMLS (SPECIALIST lexicon and Metathesaurus), heuristic language processing techniques, and an empirical scoring algorithm. KM differentiates among potentially matching Metathesaurus concepts within a source document. The authors manually identified important "gold standard" biomedical concepts within selected medical school full-content lecture documents and used these documents to compare KM concept recognition with that of a known state-of-the-art "standard"-the National Library of Medicine's MetaMap program. The number of "gold standard" concepts in each lecture document identified by either KM or MetaMap, and the cause of each failure or relative success in a random subset of documents. For 4,281 "gold standard" concepts, MetaMap matched 78% and KM 82%. Precision for "gold standard" concepts was 85% for MetaMap and 89% for KM. The heuristics of KM accurately matched acronyms, concepts underspecified in the document, and ambiguous matches. The most frequent cause of matching failures was absence of target concepts from the UMLS Metathesaurus. The prototypic KM system provided an encouraging rate of concept extraction for representative medical curricular texts. Future versions of KM should be evaluated for their ability to allow administrators, lecturers, and students to navigate through the medical curriculum to locate redundancies, find interrelated information, and identify omissions. In addition, the ability of KM to meet specific, personal information needs should be assessed.

  18. Development and Validation of a Heart Atlas to Study Cardiac Exposure to Radiation Following Treatment for Breast Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Feng, Mary, E-mail: maryfeng@umich.ed; Moran, Jean M.; Koelling, Todd

    2011-01-01

    Purpose: Cardiac toxicity is an important sequela of breast radiotherapy. However, the relationship between dose to cardiac structures and subsequent toxicity has not been well defined, partially due to variations in substructure delineation, which can lead to inconsistent dose reporting and the failure to detect potential correlations. Here we have developed a heart atlas and evaluated its effect on contour accuracy and concordance. Methods and Materials: A detailed cardiac computed tomography scan atlas was developed jointly by cardiology, cardiac radiology, and radiation oncology. Seven radiation oncologists were recruited to delineate the whole heart, left main and left anterior descending interventricularmore » branches, and right coronary arteries on four cases before and after studying the atlas. Contour accuracy was assessed by percent overlap with gold standard atlas volumes. The concordance index was also calculated. Standard radiation fields were applied. Doses to observer-contoured cardiac structures were calculated and compared with gold standard contour doses. Pre- and post-atlas values were analyzed using a paired t test. Results: The cardiac atlas significantly improved contour accuracy and concordance. Percent overlap and concordance index of observer-contoured cardiac and gold standard volumes were 2.3-fold improved for all structures (p < 0.002). After application of the atlas, reported mean doses to the whole heart, left main artery, left anterior descending interventricular branch, and right coronary artery were within 0.1, 0.9, 2.6, and 0.6 Gy, respectively, of gold standard doses. Conclusions: This validated University of Michigan cardiac atlas may serve as a useful tool in future studies assessing cardiac toxicity and in clinical trials which include dose volume constraints to the heart.« less

  19. Assessment of a novel biomechanical fracture model for distal radius fractures

    PubMed Central

    2012-01-01

    Background Distal radius fractures (DRF) are one of the most common fractures and often need surgical treatment, which has been validated through biomechanical tests. Currently a number of different fracture models are used, none of which resemble the in vivo fracture location. The aim of the study was to develop a new standardized fracture model for DRF (AO-23.A3) and compare its biomechanical behavior to the current gold standard. Methods Variable angle locking volar plates (ADAPTIVE, Medartis) were mounted on 10 pairs of fresh-frozen radii. The osteotomy location was alternated within each pair (New: 10 mm wedge 8 mm / 12 mm proximal to the dorsal / volar apex of the articular surface; Gold standard: 10 mm wedge 20 mm proximal to the articular surface). Each specimen was tested in cyclic axial compression (increasing load by 100 N per cycle) until failure or −3 mm displacement. Parameters assessed were stiffness, displacement and dissipated work calculated for each cycle and ultimate load. Significance was tested using a linear mixed model and Wald test as well as t-tests. Results 7 female and 3 male pairs of radii aged 74 ± 9 years were tested. In most cases (7/10), the two groups showed similar mechanical behavior at low loads with increasing differences at increasing loads. Overall the novel fracture model showed a significant different biomechanical behavior than the gold standard model (p < 0,001). The average final loads resisted were significantly lower in the novel model (860 N ± 232 N vs. 1250 N ± 341 N; p = 0.001). Conclusion The novel biomechanical fracture model for DRF more closely mimics the in vivo fracture site and shows a significantly different biomechanical behavior with increasing loads when compared to the current gold standard. PMID:23244634

  20. Developing a standard for de-identifying electronic patient records written in Swedish: precision, recall and F-measure in a manual and computerized annotation trial.

    PubMed

    Velupillai, Sumithra; Dalianis, Hercules; Hassel, Martin; Nilsson, Gunnar H

    2009-12-01

    Electronic patient records (EPRs) contain a large amount of information written in free text. This information is considered very valuable for research but is also very sensitive since the free text parts may contain information that could reveal the identity of a patient. Therefore, methods for de-identifying EPRs are needed. The work presented here aims to perform a manual and automatic Protected Health Information (PHI)-annotation trial for EPRs written in Swedish. This study consists of two main parts: the initial creation of a manually PHI-annotated gold standard, and the porting and evaluation of an existing de-identification software written for American English to Swedish in a preliminary automatic de-identification trial. Results are measured with precision, recall and F-measure. This study reports fairly high Inter-Annotator Agreement (IAA) results on the manually created gold standard, especially for specific tags such as names. The average IAA over all tags was 0.65 F-measure (0.84 F-measure highest pairwise agreement). For name tags the average IAA was 0.80 F-measure (0.91 F-measure highest pairwise agreement). Porting a de-identification software written for American English to Swedish directly was unfortunately non-trivial, yielding poor results. Developing gold standard sets as well as automatic systems for de-identification tasks in Swedish is feasible. However, discussions and definitions on identifiable information is needed, as well as further developments both on the tag sets and the annotation guidelines, in order to get a reliable gold standard. A completely new de-identification software needs to be developed.

  1. A prospective study assessing agreement and reliability of a geriatric evaluation.

    PubMed

    Locatelli, Isabella; Monod, Stéfanie; Cornuz, Jacques; Büla, Christophe J; Senn, Nicolas

    2017-07-19

    The present study takes place within a geriatric program, aiming at improving the diagnosis and management of geriatric syndromes in primary care. Within this program it was of prime importance to be able to rely on a robust and reproducible geriatric consultation to use as a gold standard for evaluating a primary care brief assessment tool. The specific objective of the present study was thus assessing the agreement and reliability of a comprehensive geriatric consultation. The study was conducted at the outpatient clinic of the Service of Geriatric Medicine, University of Lausanne, Switzerland. All community-dwelling older persons aged 70 years and above were eligible. Patients were excluded if they hadn't a primary care physician, they were unable to speak French, or they were already assessed by a geriatrician within the last 12 months. A set of 9 geriatricians evaluated 20 patients. Each patient was assessed twice within a 2-month delay. Geriatric consultations were based on a structured evaluation process, leading to rating the following geriatric conditions: functional, cognitive, visual, and hearing impairment, mood disorders, risk of fall, osteoporosis, malnutrition, and urinary incontinence. Reliability and agreement estimates on each of these items were obtained using a three-way Intraclass Correlation and a three-way Observed Disagreement index. The latter allowed a decomposition of overall disagreement into disagreements due to each source of error variability (visit, rater and random). Agreement ranged between 0.62 and 0.85. For most domains, geriatrician-related error variability explained an important proportion of disagreement. Reliability ranged between 0 and 0.8. It was poor/moderate for visual impairment, malnutrition and risk of fall, and good/excellent for functional/cognitive/hearing impairment, osteoporosis, incontinence and mood disorders. Six out of nine items of the geriatric consultation described in this study (functional/cognitive/hearing impairment, osteoporosis, incontinence and mood disorders) present a good to excellent reliability and can safely be used as a reference (gold standard) to evaluate the diagnostic performance of a primary care brief assessment tool. More objective/significant measures are needed to improve reliability of malnutrition, visual impairment, and risk of fall assessment before they can serve as a safe gold standard of a primary care tool.

  2. Sensitivity of Direct Culture, Enrichment and PCR for Detection of Campylobacter jejuni and C. coli in Broiler Flocks at Slaughter.

    PubMed

    Rodgers, J D; Simpkin, E; Lee, R; Clifton-Hadley, F A; Vidal, A B

    2017-06-01

    Broiler chicken flocks are a significant source of Campylobacter jejuni and Campylobacter coli that result in the major public health problem of campylobacteriosis. Accurate estimates of the prevalence of both C. coli and C. jejuni in flocks would enhance epidemiological understanding, risk assessment and control options. This study combined results from a panel of 10 detection tests (direct culture, enrichment and PCR) on caecal samples from flocks at slaughter. A parallel interpretation approach was used to determine the presence of Campylobacter spp. and for C. jejuni and C. coli individually. The sample was considered positive if at least one method detected the target and this interpretation was taken to represent a 'proxy gold standard' for detection in the absence of a gold standard reference test. The sensitivity of each individual method to detect Campylobacter spp., C. jejuni and C. coli was then estimated relative to the proxy gold standard. Enrichment in adapted Exeter broth (deficient in polymyxin B) with a resuscitation step was 100% sensitive, whilst direct culture on modified charcoal cefoperazone deoxycholate agar (mCCDA) was highly sensitive (97.9%). Enrichment methods using Preston broth and Bolton broth were significantly less sensitive. Enrichment in Exeter broth promoted the recovery of C. jejuni, whilst enrichment in Bolton broth favoured C. coli. A RT-PCR detection test could identify 80% of flocks that were co-colonised with both species. This study found that 76.3% (n = 127) of flocks were colonised with Campylobacter spp. The majority (95.9%) of Campylobacter-positive flocks were colonised with C. jejuni; however, approximately one-third of positive flocks were simultaneously colonised with both C. jejuni and C. coli. The findings highlight the impact of different detection methodologies on the accuracy of the estimated incidence of both C. jejuni and C. coli entering the abattoir within broiler flocks and the associated public health risks. © 2016 Crown copyright. Zoonoses and Public Health published by Blackwell Verlag GmbH. This article is published with the permission of the Controller of HMSO and the Queen's Printer for Scotland.

  3. Absolute measurement of (198)Au activity in gold foil using plastic scintillators and a well-type NaI(Tl) detector.

    PubMed

    Kim, Yun Ho; Kim, Jungho; Lee, Jong-Man; Park, Hyeonseo

    2016-03-01

    A beta-gamma coincidence system has been developed for measuring (198)Au activity in gold foils. The system was validated by Monte Carlo simulations and by measuring the activity of a (60)Co point-source. To study effects such as self-shielding of beta particles in gold foils, (198)Au activity measurements and simulations were performed for various scintillators and foil sizes. The measured (198)Au activities were ~1% above the reference activity, which might be due to self-shielding of beta particles. The measured and simulated (198)Au activities agreed, suggesting feasibility of precise activity measurement. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Identification and Classification of Player Types in Massive Multiplayer Online Games Using Avatar Behavior

    DTIC Science & Technology

    2011-08-01

    display specific characteristics that can be used to identify the player behind the avatar. This kind of information can be used by game companies to...bring in players. This kind of information can also be used to identify deviant behaviors such as ‘gold farming.’ Gold farming refers to the practice...unique behaviors associated with a player controlling the avatar. Some of the observable information used to identify these unique behaviors are

  5. Making and Measuring the California History Standards

    ERIC Educational Resources Information Center

    Fogo, Bradley

    2011-01-01

    The California history and social science standards-based reform has been touted as the "gold standard" for state history curricula. But the standards, framework, and tests that constitute this reform provide inconsistent and contradictory criteria for teaching and assessing history and social science. An examination of the political…

  6. Fungus-mediated synthesis of gold nanoparticles and standardization of parameters for its biosynthesis.

    PubMed

    Tidke, Pritish R; Gupta, Indarchand; Gade, Aniket K; Rai, Mahendra

    2014-12-01

    We report the extracellular biosynthesis of gold nanoparticles (AuNPs) using a fungus Fusarium acuminatum. Mycosynthesis of Au-NPs was carried out by challenging the fungal cells filtrate with HAuCl 4 solution (1 mM), as nanoparticles synthesizing enzyme secrete extracellularly by the fungi. The AuNPs were characterized with the help of UV-Visible spectrophotometer, Fourier Transform Infrared spectroscopy, Zeta Potential, X-ray diffraction (XRD) and Transmission electron microscopy (TEM). We observed absorbance peak in between 520 nm-550 nm corresponding to the surface plasmon absorbance of the gold nanoparticles. The nanoparticles synthesized in the present investigation were found to be capped by proteins. XRD results showed that the distinctive formation of crystalline gold nanoparticles in the solution. The spherical and polydispersed AuNPs in the range 8 to 28 nm with average size of 17 nm were observed by TEM analysis. We also standardized the parameters like the effect of pH, temperature and salt concentration on the biosynthesis of gold nanoparticles. It was found that acidic pH, 1 mM salt concentration and 37 (°)C temperature were found to be optimum for the synthesis of Au-NPs. Therefore, the present study introduces the easy, better and cheaper method for biosynthesis of AuNPs.

  7. The Process of People Gold Mining in Paningkaban Village Banyumas Indonesia

    NASA Astrophysics Data System (ADS)

    Muslihudin; Bambang, Azis Nur; Hendarto, Eko; Putranto, Thomas Triadi

    2018-02-01

    Gold mining in Paningkaban Banyumas conducted by the community is called the People gold mining. At the beginning, many miners from outside the region have involved and transferred of method, technic and knowledge about gold mining to local people. The aim of the study is to identify the existing process of public gold mining. The method of the study is qualitative by using observation and interview. The result showed that the mining process are: 1. Determining the location of mining well; in this determination there are two references; rational and intuition 2. Mining; at this stage, a deep well is drawn about 50-100 meters that leads vertically and horizontally. It is the most high-risk stage because of work accidents that occurred and potentially environment destruction. 3. Pulverization; this stage is classified as the lowest level of difficulty and risk, therefore in this work many woman included. 4. Rolling; in this stage involves enough technology, electrical mechanic and energy with the dynamo and using mercury that potentially contaminate environment. 5. Filtering; this stage is a quite risky because the workers contact directly with mercury. 6. Burning; is the shortest process to separate mercury with gold grains. 7. Sales to local buyer guided by the international gold market in every Thursday.

  8. Effect of gold nanoparticles on adipogenic differentiation of human mesenchymal stem cells

    NASA Astrophysics Data System (ADS)

    Kohl, Yvonne; Gorjup, Erwin; Katsen-Globa, Alisa; Büchel, Claudia; von Briesen, Hagen; Thielecke, Hagen

    2011-12-01

    Gold nanoparticles are very attractive for biomedical products. However, there is a serious lack of information concerning the biological activity of nanosized gold in human tissue cells. An influence of nanoparticles on stem cells might lead to unforeseen consequences to organ and tissue functions as long as all cells arising from the initial stem cell might be subsequently damaged. Therefore the effect of negatively charged gold nanoparticles (9 and 95 nm), which are certified as reference material for preclinical biomedical research, on the adipogenic differentiation of human mesenchymal stem cells (hMSCs) is investigated here. Bone marrow hMSCs are chosen as differentiation model since bone marrow hMSCs are well characterized and their differentiation into the adipogenic lineage shows clear and easily detectable differentiation. In this study effects of gold nanoparticles on adipogenic differentiation are analyzed regarding fat storage and mitochondrial activity after different exposure times (4-21 days). Using time lapse microscopy the differentiation progress under chronically gold nanoparticle treatment is continuously investigated. In this preliminary study, chronically treatment of adipogenic differentiating hMSCs with gold nanoparticles resulted in a reduced number and size of lipid vacuoles and reduced mitochondrial activity depending on the applied concentration and the surface charge of the particles.

  9. Enhanced photoinactivation of Staphylococcus aureus with nanocomposites containing plasmonic particles and hematoporphyrin.

    PubMed

    Khlebtsov, Boris N; Tuchina, Elena S; Khanadeev, Vitaly A; Panfilova, Elizaveta V; Petrov, Pavel O; Tuchin, Valery V; Khlebtsov, Nikolai G

    2013-04-01

    We fabricated composite nanoparticles consisting of a plasmonic core (gold nanorods or gold-silver nanocages) and a hematoporphyrin-doped silica shell. The dual photodynamic and photothermal activities of such nanoparticles against Staphylococcus aureus 209 P were studied and compared with the activities of reference solutions (hematoporphyrin or silica-coated plasmonic nanoparticles). Bacteria were incubated with nanocomposites or with the reference solutions for 15 min, which was followed by CW light irradiation with a few exposures of 5 to 30 min. To stimulate the photodynamic and photothermal activities of the nanocomposites, we used LEDs (405 and 625 nm) and a NIR laser (808 nm), respectively. We observed enhanced inactivation of S. aureus 209 P by nanocomposites in comparison with the reference solutions. By using fluorescence microscopy and spectroscopy, we explain the enhanced antimicrobial effect of hematoporphyrin-doped nanocomposites by their selective accumulation in the vicinity of the bacteria. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Novel hand-held device for exhaled nitric oxide-analysis in research and clinical applications.

    PubMed

    Hemmingsson, Tryggve; Linnarsson, Dag; Gambert, Rudolf

    2004-12-01

    Changes in expired nitric oxide (NO) occur in airway inflammation and have proved to be important in the monitoring of inflammatory disease processes such as asthma. We set out to develop a novel hand-held NO-analyzer with a performance comparable to the present more costly and complex chemiluminescence instruments. The new device is based on a specially designed electrochemical sensor, where we have developed a novel sampling and analysis technology, compensating for the relatively slow response properties of the electrochemical sensor technique. A Lowest Detection Limit in NO-analysis from reference gas tests of less than 3 ppb and a response time of 15 seconds together with an average precision in human breath measurements of 1.4 ppb were obtained. We also show an agreement with the existing 'gold standard' FENO measurement technique, within 0.5 ppb in a group of 19 subjects together with a high linearity and accuracy compared to reference gases. The new analyzer enables affordable monitoring of inflammatory airway diseases in research and routine clinical practice.

  11. Magnetic Stirrer Method for the Detection of Trichinella Larvae in Muscle Samples.

    PubMed

    Mayer-Scholl, Anne; Pozio, Edoardo; Gayda, Jennifer; Thaben, Nora; Bahn, Peter; Nöckler, Karsten

    2017-03-03

    Trichinellosis is a debilitating disease in humans and is caused by the consumption of raw or undercooked meat of animals infected with the nematode larvae of the genus Trichinella. The most important sources of human infections worldwide are game meat and pork or pork products. In many countries, the prevention of human trichinellosis is based on the identification of infected animals by means of the artificial digestion of muscle samples from susceptible animal carcasses. There are several methods based on the digestion of meat but the magnetic stirrer method is considered the gold standard. This method allows the detection of Trichinella larvae by microscopy after the enzymatic digestion of muscle samples and subsequent filtration and sedimentation steps. Although this method does not require special and expensive equipment, internal controls cannot be used. Therefore, stringent quality management should be applied throughout the test. The aim of the present work is to provide detailed handling instructions and critical control points of the method to analysts, based on the experience of the European Union Reference Laboratory for Parasites and the National Reference Laboratory of Germany for Trichinella.

  12. Advances in spectroscopic methods for quantifying soil carbon

    USGS Publications Warehouse

    Reeves, James B.; McCarty, Gregory W.; Calderon, Francisco; Hively, W. Dean

    2012-01-01

    The current gold standard for soil carbon (C) determination is elemental C analysis using dry combustion. However, this method requires expensive consumables, is limited by the number of samples that can be processed (~100/d), and is restricted to the determination of total carbon. With increased interest in soil C sequestration, faster methods of analysis are needed, and there is growing interest in methods based on diffuse reflectance spectroscopy in the visible, near-infrared or mid-infrared spectral ranges. These spectral methods can decrease analytical requirements and speed sample processing, be applied to large landscape areas using remote sensing imagery, and be used to predict multiple analytes simultaneously. However, the methods require localized calibrations to establish the relationship between spectral data and reference analytical data, and also have additional, specific problems. For example, remote sensing is capable of scanning entire watersheds for soil carbon content but is limited to the surface layer of tilled soils and may require difficult and extensive field sampling to obtain proper localized calibration reference values. The objective of this chapter is to discuss the present state of spectroscopic methods for determination of soil carbon.

  13. A literature search tool for intelligent extraction of disease-associated genes.

    PubMed

    Jung, Jae-Yoon; DeLuca, Todd F; Nelson, Tristan H; Wall, Dennis P

    2014-01-01

    To extract disorder-associated genes from the scientific literature in PubMed with greater sensitivity for literature-based support than existing methods. We developed a PubMed query to retrieve disorder-related, original research articles. Then we applied a rule-based text-mining algorithm with keyword matching to extract target disorders, genes with significant results, and the type of study described by the article. We compared our resulting candidate disorder genes and supporting references with existing databases. We demonstrated that our candidate gene set covers nearly all genes in manually curated databases, and that the references supporting the disorder-gene link are more extensive and accurate than other general purpose gene-to-disorder association databases. We implemented a novel publication search tool to find target articles, specifically focused on links between disorders and genotypes. Through comparison against gold-standard manually updated gene-disorder databases and comparison with automated databases of similar functionality we show that our tool can search through the entirety of PubMed to extract the main gene findings for human diseases rapidly and accurately.

  14. A method for quantitative analysis of standard and high-throughput qPCR expression data based on input sample quantity.

    PubMed

    Adamski, Mateusz G; Gumann, Patryk; Baird, Alison E

    2014-01-01

    Over the past decade rapid advances have occurred in the understanding of RNA expression and its regulation. Quantitative polymerase chain reactions (qPCR) have become the gold standard for quantifying gene expression. Microfluidic next generation, high throughput qPCR now permits the detection of transcript copy number in thousands of reactions simultaneously, dramatically increasing the sensitivity over standard qPCR. Here we present a gene expression analysis method applicable to both standard polymerase chain reactions (qPCR) and high throughput qPCR. This technique is adjusted to the input sample quantity (e.g., the number of cells) and is independent of control gene expression. It is efficiency-corrected and with the use of a universal reference sample (commercial complementary DNA (cDNA)) permits the normalization of results between different batches and between different instruments--regardless of potential differences in transcript amplification efficiency. Modifications of the input quantity method include (1) the achievement of absolute quantification and (2) a non-efficiency corrected analysis. When compared to other commonly used algorithms the input quantity method proved to be valid. This method is of particular value for clinical studies of whole blood and circulating leukocytes where cell counts are readily available.

  15. Traceable Measurements of Seebeck Coefficients of Thermoelectric Materials by Using Noble Metal Thermocouples

    NASA Astrophysics Data System (ADS)

    Haupt, Sebastian; Edler, Frank

    2018-06-01

    The characterization of thermoelectric materials as reference materials for Seebeck coefficients at the Physikalisch-Technische Bundesanstalt (PTB) is based on the usage of gold/platinum differential thermocouples. In the case of thermoelectric materials containing silicon, the gold/platinum thermocouples are insufficient due to reactions with the silicon when the samples are at higher temperatures. To overcome this limitation and to expand the temperature range for the certification process, platinum/palladium thermocouples were incorporated in the measurement setup. This paper discusses the influence of the different differential thermocouples used for the measurement of the Seebeck coefficients. Results of a comparative investigation of Seebeck coefficient measurements of a metallic and two semiconducting reference materials in the temperature range from 300 K to 870 K are presented.

  16. Exome copy number variation detection: Use of a pool of unrelated healthy tissue as reference sample.

    PubMed

    Wenric, Stephane; Sticca, Tiberio; Caberg, Jean-Hubert; Josse, Claire; Fasquelle, Corinne; Herens, Christian; Jamar, Mauricette; Max, Stéphanie; Gothot, André; Caers, Jo; Bours, Vincent

    2017-01-01

    An increasing number of bioinformatic tools designed to detect CNVs (copy number variants) in tumor samples based on paired exome data where a matched healthy tissue constitutes the reference have been published in the recent years. The idea of using a pool of unrelated healthy DNA as reference has previously been formulated but not thoroughly validated. As of today, the gold standard for CNV calling is still aCGH but there is an increasing interest in detecting CNVs by exome sequencing. We propose to design a metric allowing the comparison of two CNV profiles, independently of the technique used and assessed the validity of using a pool of unrelated healthy DNA instead of a matched healthy tissue as reference in exome-based CNV detection. We compared the CNV profiles obtained with three different approaches (aCGH, exome sequencing with a matched healthy tissue as reference, exome sequencing with a pool of eight unrelated healthy tissue as reference) on three multiple myeloma samples. We show that the usual analyses performed to compare CNV profiles (deletion/amplification ratios and CNV size distribution) lack in precision when confronted with low LRR values, as they only consider the binary status of each CNV. We show that the metric-based distance constitutes a more accurate comparison of two CNV profiles. Based on these analyses, we conclude that a reliable picture of CNV alterations in multiple myeloma samples can be obtained from whole-exome sequencing in the absence of a matched healthy sample. © 2016 WILEY PERIODICALS, INC.

  17. Near-edge study of gold-substituted YBa2Cu3O(7-delta)

    NASA Technical Reports Server (NTRS)

    Ruckman, Mark W.; Hepp, Aloysius F.

    1991-01-01

    The valence of Cu and Au in YBa2Au0.3Cu2.7O7-delta was investigated using X-ray absorption near edge structure (XANES). X-ray and neutron diffraction studies indicate that Au goes on the Cu(1) site and Cu K-edge XANES shows that this has little effect on the oxidation state of the remaining copper. The Au L3 edge develops a white line feature whose position lies between that of trivalent gold oxide and monovalent potassium gold cyanide, and whose height relative to the edge step is smaller than in the two reference compounds. The appearance of the Au L3 edge suggests that fewer Au 3d states are involved in forming the Au-O bond in YBa2Au0.3Cu2.7O7-delta than in trivalent gold oxide.

  18. Near-edge study of gold-substituted YBa2Cu3O(7-delta)

    NASA Technical Reports Server (NTRS)

    Ruckman, Mark W.; Hepp, Aloysius F.

    1991-01-01

    The valence of Cu and Au in YBa2Au0.3Cu2.7O7-delta was investigated using x-ray absorption near edge structure (XANES). X-ray and neutron diffraction studies indicate that Au goes on the Cu(1) site and Cu K-edge XANES shows that this has little effect on the oxidation state of the remaining copper. The Au L3 edge develops a white line feature whose position lies between that of trivalent gold oxide and monovalent potassium gold cyanide, and whose height relative to the edge step is smaller than in the two reference compounds. The appearance of the Au L3 edge suggests that fewer Au 3d states are involved in forming the Au-O bond in YBa2Au0.3Cu2.7O7-delta than in trivalent gold oxide.

  19. Notes on dumping gold beam in the AGS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gardner, C.J.; Ahrens, L.; Thieberger, P.

    2010-08-01

    Localized losses of gold beam in the AGS during RHIC Run 8 produced vacuum leaks which required the replacement of several vacuum chambers. A review of what happened and why was given by Leif Ahrens at the Run 8 Retreat. The following notes trace the subsequent development of clean dumping of gold beam on the beam dump in the J10 straight. The novel idea of stripping Au77+ ions in order to put them directly into the upstream face of the dump was introduced by Leif Ahrens and developed by all three of us. George Mahler made the actual stripping devicemore » and Dave Gassner developed its control. Leif Ahrens successfully commissioned the device with gold beam during Run 10. The reader may find it helpful to first view the figures herein and then refer to the text for details.« less

  20. Gold Nanoparticles in Biology and Medicine: Recent Advances and Prospects

    PubMed Central

    Dykman, L.A.; Khlebtsov, N.G.

    2011-01-01

    Functionalized gold nanoparticles with controlled geometrical and optical properties are the subject of intensive studies and biomedical applications, including genomics, biosensorics, immunoassays, clinical chemistry, laser phototherapy of cancer cells and tumors, the targeted delivery of drugs, DNA and antigens, optical bioimaging and the monitoring of cells and tissues with the use of state-of-the-art detection systems. This work will provide an overview of the recent advances and current challenges facing the biomedical application of gold nanoparticles of various sizes, shapes, and structures. The review is focused on the application of gold nanoparticle conjugates in biomedical diagnostics and analytics, photothermal and photodynamic therapies, as a carrier for delivering target molecules, and on the immunological and toxicological properties. Keeping in mind the huge volume and high speed of the data update rate, 2/3 of our reference list (certainly restricted to 250 Refs.) includes publications encompassing the past 5 years. PMID:22649683

  1. Bedside diagnosis of dysphagia: a systematic review.

    PubMed

    O'Horo, John C; Rogus-Pulia, Nicole; Garcia-Arguello, Lisbeth; Robbins, JoAnne; Safdar, Nasia

    2015-04-01

    Dysphagia is associated with aspiration, pneumonia, and malnutrition, but remains challenging to identify at the bedside. A variety of exam protocols and maneuvers are commonly used, but the efficacy of these maneuvers is highly variable. We conducted a comprehensive search of 7 databases, including MEDLINE, Embase, and Scopus, from each database's earliest inception through June 9, 2014. Studies reporting diagnostic performance of a bedside examination maneuver compared to a reference gold standard (videofluoroscopic swallow study or flexible endoscopic evaluation of swallowing with sensory testing) were included for analysis. From each study, data were abstracted based on the type of diagnostic method and reference standard study population and inclusion/exclusion characteristics, design, and prediction of aspiration. The search strategy identified 38 articles meeting inclusion criteria. Overall, most bedside examinations lacked sufficient sensitivity to be used for screening purposes across all patient populations examined. Individual studies found dysphonia assessments, abnormal pharyngeal sensation assessments, dual axis accelerometry, and 1 description of water swallow testing to be sensitive tools, but none were reported as consistently sensitive. A preponderance of identified studies was in poststroke adults, limiting the generalizability of results. No bedside screening protocol has been shown to provide adequate predictive value for presence of aspiration. Several individual exam maneuvers demonstrated reasonable sensitivity, but reproducibility and consistency of these protocols was not established. More research is needed to design an optimal protocol for dysphagia detection. © 2015 Society of Hospital Medicine.

  2. Pathological Bases for a Robust Application of Cancer Molecular Classification

    PubMed Central

    Diaz-Cano, Salvador J.

    2015-01-01

    Any robust classification system depends on its purpose and must refer to accepted standards, its strength relying on predictive values and a careful consideration of known factors that can affect its reliability. In this context, a molecular classification of human cancer must refer to the current gold standard (histological classification) and try to improve it with key prognosticators for metastatic potential, staging and grading. Although organ-specific examples have been published based on proteomics, transcriptomics and genomics evaluations, the most popular approach uses gene expression analysis as a direct correlate of cellular differentiation, which represents the key feature of the histological classification. RNA is a labile molecule that varies significantly according with the preservation protocol, its transcription reflect the adaptation of the tumor cells to the microenvironment, it can be passed through mechanisms of intercellular transference of genetic information (exosomes), and it is exposed to epigenetic modifications. More robust classifications should be based on stable molecules, at the genetic level represented by DNA to improve reliability, and its analysis must deal with the concept of intratumoral heterogeneity, which is at the origin of tumor progression and is the byproduct of the selection process during the clonal expansion and progression of neoplasms. The simultaneous analysis of multiple DNA targets and next generation sequencing offer the best practical approach for an analytical genomic classification of tumors. PMID:25898411

  3. A comparison of tuberculosis diagnostic systems in a retrospective cohort of HIV-infected children in Rio de Janeiro, Brazil.

    PubMed

    David, Solange Gonçalves; Lovero, Kathryn L; Pombo March, Maria de Fátima B; Abreu, Thalita G; Ruffino Netto, Antonio; Kritski, Afranio L; Sant'Anna, Clemax C

    2017-06-01

    The diagnosis of pediatric tuberculosis (TB) presents many challenges, and is further complicated in HIV-infected patients. While many diagnostic systems have been proposed, there is no pediatric TB diagnosis gold standard. The outcomes of four TB diagnostic systems in HIV-infected children were compared in this study. A retrospective cohort study was conducted at a TB/HIV reference hospital in Rio de Janeiro. HIV-infected pediatric patients evaluated for TB from 1998 to 2010 were reassessed using four diagnostic systems: Kenneth Jones, 1969; Tidjani, 1986; Ben Marais, 2006; Brazilian Ministry of Health, 2010. Results were compared to standardized diagnoses made by an expert panel of physicians. Of the 121 patients in the study cohort, the expert panel diagnosed 64 as TB and 57 as not TB cases. The Tidjani system showed the highest diagnostic accuracy, with and without the inclusion of microbiological data. The Tidjani and Kenneth Jones systems produced fewer false-positives, and the Ben Marais and Ministry of Health fewer false-negatives. Across systems, there was little agreement between TB diagnoses. In HIV-infected pediatric patients, the Ben Marais and Ministry of Health systems are useful for TB diagnostic screening, whereas the Tidjani and Kenneth Jones systems are best used in a reference center setting. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  4. Using collective expert judgements to evaluate quality measures of mass spectrometry images.

    PubMed

    Palmer, Andrew; Ovchinnikova, Ekaterina; Thuné, Mikael; Lavigne, Régis; Guével, Blandine; Dyatlov, Andrey; Vitek, Olga; Pineau, Charles; Borén, Mats; Alexandrov, Theodore

    2015-06-15

    Imaging mass spectrometry (IMS) is a maturating technique of molecular imaging. Confidence in the reproducible quality of IMS data is essential for its integration into routine use. However, the predominant method for assessing quality is visual examination, a time consuming, unstandardized and non-scalable approach. So far, the problem of assessing the quality has only been marginally addressed and existing measures do not account for the spatial information of IMS data. Importantly, no approach exists for unbiased evaluation of potential quality measures. We propose a novel approach for evaluating potential measures by creating a gold-standard set using collective expert judgements upon which we evaluated image-based measures. To produce a gold standard, we engaged 80 IMS experts, each to rate the relative quality between 52 pairs of ion images from MALDI-TOF IMS datasets of rat brain coronal sections. Experts' optional feedback on their expertise, the task and the survey showed that (i) they had diverse backgrounds and sufficient expertise, (ii) the task was properly understood, and (iii) the survey was comprehensible. A moderate inter-rater agreement was achieved with Krippendorff's alpha of 0.5. A gold-standard set of 634 pairs of images with accompanying ratings was constructed and showed a high agreement of 0.85. Eight families of potential measures with a range of parameters and statistical descriptors, giving 143 in total, were evaluated. Both signal-to-noise and spatial chaos-based measures performed highly with a correlation of 0.7 to 0.9 with the gold standard ratings. Moreover, we showed that a composite measure with the linear coefficients (trained on the gold standard with regularized least squares optimization and lasso) showed a strong linear correlation of 0.94 and an accuracy of 0.98 in predicting which image in a pair was of higher quality. The anonymized data collected from the survey and the Matlab source code for data processing can be found at: https://github.com/alexandrovteam/IMS_quality. © The Author 2015. Published by Oxford University Press.

  5. Using collective expert judgements to evaluate quality measures of mass spectrometry images

    PubMed Central

    Palmer, Andrew; Ovchinnikova, Ekaterina; Thuné, Mikael; Lavigne, Régis; Guével, Blandine; Dyatlov, Andrey; Vitek, Olga; Pineau, Charles; Borén, Mats; Alexandrov, Theodore

    2015-01-01

    Motivation: Imaging mass spectrometry (IMS) is a maturating technique of molecular imaging. Confidence in the reproducible quality of IMS data is essential for its integration into routine use. However, the predominant method for assessing quality is visual examination, a time consuming, unstandardized and non-scalable approach. So far, the problem of assessing the quality has only been marginally addressed and existing measures do not account for the spatial information of IMS data. Importantly, no approach exists for unbiased evaluation of potential quality measures. Results: We propose a novel approach for evaluating potential measures by creating a gold-standard set using collective expert judgements upon which we evaluated image-based measures. To produce a gold standard, we engaged 80 IMS experts, each to rate the relative quality between 52 pairs of ion images from MALDI-TOF IMS datasets of rat brain coronal sections. Experts’ optional feedback on their expertise, the task and the survey showed that (i) they had diverse backgrounds and sufficient expertise, (ii) the task was properly understood, and (iii) the survey was comprehensible. A moderate inter-rater agreement was achieved with Krippendorff’s alpha of 0.5. A gold-standard set of 634 pairs of images with accompanying ratings was constructed and showed a high agreement of 0.85. Eight families of potential measures with a range of parameters and statistical descriptors, giving 143 in total, were evaluated. Both signal-to-noise and spatial chaos-based measures performed highly with a correlation of 0.7 to 0.9 with the gold standard ratings. Moreover, we showed that a composite measure with the linear coefficients (trained on the gold standard with regularized least squares optimization and lasso) showed a strong linear correlation of 0.94 and an accuracy of 0.98 in predicting which image in a pair was of higher quality. Availability and implementation: The anonymized data collected from the survey and the Matlab source code for data processing can be found at: https://github.com/alexandrovteam/IMS_quality. Contact: theodore.alexandrov@embl.de PMID:26072506

  6. Improving practice in community-based settings: a randomized trial of supervision - study protocol.

    PubMed

    Dorsey, Shannon; Pullmann, Michael D; Deblinger, Esther; Berliner, Lucy; Kerns, Suzanne E; Thompson, Kelly; Unützer, Jürgen; Weisz, John R; Garland, Ann F

    2013-08-10

    Evidence-based treatments for child mental health problems are not consistently available in public mental health settings. Expanding availability requires workforce training. However, research has demonstrated that training alone is not sufficient for changing provider behavior, suggesting that ongoing intervention-specific supervision or consultation is required. Supervision is notably under-investigated, particularly as provided in public mental health. The degree to which supervision in this setting includes 'gold standard' supervision elements from efficacy trials (e.g., session review, model fidelity, outcome monitoring, skill-building) is unknown. The current federally-funded investigation leverages the Washington State Trauma-focused Cognitive Behavioral Therapy Initiative to describe usual supervision practices and test the impact of systematic implementation of gold standard supervision strategies on treatment fidelity and clinical outcomes. The study has two phases. We will conduct an initial descriptive study (Phase I) of supervision practices within public mental health in Washington State followed by a randomized controlled trial of gold standard supervision strategies (Phase II), with randomization at the clinician level (i.e., supervisors provide both conditions). Study participants will be 35 supervisors and 130 clinicians in community mental health centers. We will enroll one child per clinician in Phase I (N = 130) and three children per clinician in Phase II (N = 390). We use a multi-level mixed within- and between-subjects longitudinal design. Audio recordings of supervision and therapy sessions will be collected and coded throughout both phases. Child outcome data will be collected at the beginning of treatment and at three and six months into treatment. This study will provide insight into how supervisors can optimally support clinicians delivering evidence-based treatments. Phase I will provide descriptive information, currently unavailable in the literature, about commonly used supervision strategies in community mental health. The Phase II randomized controlled trial of gold standard supervision strategies is, to our knowledge, the first experimental study of gold standard supervision strategies in community mental health and will yield needed information about how to leverage supervision to improve clinician fidelity and client outcomes. ClinicalTrials.gov NCT01800266.

  7. Mercury Distribution in the Processing of Jatiroto Gold Mine Wonogiri Central Java Indonesia

    NASA Astrophysics Data System (ADS)

    Fitri Yudiantoro, Dwi; Nurcholis, Muhammad; Sri Sayudi, Dewi; Abdurrachman, Mirzam; Paramita Haty, Intan; Pambudi, Wiryan; Subroborini, Arum

    2017-06-01

    The research area is one of the Wonogiri gold producer. In this region there are nearly 30 gold processing locations. This area has a steep morphology which is part of Mt. Mas. The work of the gold processing is a part time job besides for the local farmer population. To get the gold bearing rocks, are by digging holes manually around Mt. Mas, while gold processing is carried out in their homes. As a result of these activities, then identified the distribution of mercury in the surrounding settlements. Analytical methods used in this study is the measurement mercury content using Hg meter on altered rocks, soil and using XRF (X-Ray Fluorescence) for plant samples. This results of research shows that there are conducted on mercury contents in the altered rocks, soil and plants showed significant mercury contents in altered rocks, soil and plants. This proves that mercury has polluted the environment surrounding residents, both of people living in the hill down on the lower plain areas. The results of this study are expected to be used as reference to help overcome the pollution of the area.

  8. Extraction of gold (Au) particles from sea water by Delftia Acidovorans microbes

    NASA Astrophysics Data System (ADS)

    Yusoff, A. H. M.; Nading, M. E.; Salimi, M. N.

    2017-10-01

    Gold-mining activities have been an issue, especially when it involves in contamination of chemicals, for example arsenic and mercury. However, despite of these hazards, gold-mining activities are still being conducted. This is because the gold is worth, regardless of the problems. Gold-mining, as known needs a very large area of land, or site plant. Vast amount of labor force, mechanical force and fund are a must in order for the mining process to be continued. High demand of gold, made gold-mining industries as ones of the most profitable industries in the world. Thus, this has encouraged another alternative way to extract gold. At the mining site, researchers found that biomineralization of gold by Delftia acidovorans can be conducted. How it is done still cannot be understood. It is said that the bacteria secretes secondary metabolites, Delftibactin as a defensive mechanism against the toxicity of the soluble gold. Researchers try to find another source of elemental gold besides of the earth’s core. The options are either lava of a volcano or ocean. Here, the focus is seawater. The problem of seawater is that its composition still not yet to be proved. Dissolve gold existed as gold chloride in seawater, but in a very small amount. So, the gold separation should be focused, in order to make this process to be a successful one. Factors such as depth, climate, region, temperature need to be considered. If this difference affecting the separating process, standardized seawater composition have to be proposed.

  9. Comparison of five methods for the estimation of methane production from vented in vitro systems.

    PubMed

    Alvarez Hess, P S; Eckard, R J; Jacobs, J L; Hannah, M C; Moate, P J

    2018-05-23

    There are several methods for estimating methane production (MP) from feedstuffs in vented in vitro systems. One method (A; "gold standard") measures methane proportions in the incubation bottle's head space (HS) and in the vented gas collected in gas bags. Four other methods (B, C, D and E) measure methane proportion in a single gas sample from HS. Method B assumes the same methane proportion in the vented gas as in HS, method C assumes constant methane to carbon dioxide ratio, method D has been developed based on empirical data and method E assumes constant individual venting volumes. This study aimed to compare the MP predictions from these methods to that of the gold standard method under different incubation scenarios, to validate these methods based on their concordance with a gold standard method. Methods C, D and E had greater concordance (0.85, 0.88 and 0.81), lower root mean square error (RMSE) (0.80, 0.72 and 0.85) and lower mean bias (0.20, 0.35, -0.35) with the gold standard than did method B (concordance 0.67, RMSE 1.49 and mean bias 1.26). Methods D and E were simpler to perform than method C and method D was slightly more accurate than method E. Based on precision, accuracy and simplicity of implementation, it is recommended that, when method A cannot be used, methods D and E are preferred to estimate MP from vented in vitro systems. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  10. Development of Gold Standard Ion-Selective Electrode-Based Methods for Fluoride Analysis

    PubMed Central

    Martínez-Mier, E.A.; Cury, J.A.; Heilman, J.R.; Katz, B.P.; Levy, S.M.; Li, Y.; Maguire, A.; Margineda, J.; O’Mullane, D.; Phantumvanit, P.; Soto-Rojas, A.E.; Stookey, G.K.; Villa, A.; Wefel, J.S.; Whelton, H.; Whitford, G.M.; Zero, D.T.; Zhang, W.; Zohouri, V.

    2011-01-01

    Background/Aims: Currently available techniques for fluoride analysis are not standardized. Therefore, this study was designed to develop standardized methods for analyzing fluoride in biological and nonbiological samples used for dental research. Methods A group of nine laboratories analyzed a set of standardized samples for fluoride concentration using their own methods. The group then reviewed existing analytical techniques for fluoride analysis, identified inconsistencies in the use of these techniques and conducted testing to resolve differences. Based on the results of the testing undertaken to define the best approaches for the analysis, the group developed recommendations for direct and microdiffusion methods using the fluoride ion-selective electrode. Results Initial results demonstrated that there was no consensus regarding the choice of analytical techniques for different types of samples. Although for several types of samples, the results of the fluoride analyses were similar among some laboratories, greater differences were observed for saliva, food and beverage samples. In spite of these initial differences, precise and true values of fluoride concentration, as well as smaller differences between laboratories, were obtained once the standardized methodologies were used. Intraclass correlation coefficients ranged from 0.90 to 0.93, for the analysis of a certified reference material, using the standardized methodologies. Conclusion The results of this study demonstrate that the development and use of standardized protocols for F analysis significantly decreased differences among laboratories and resulted in more precise and true values. PMID:21160184

  11. Sixty-five years since the New York heat wave: advances in sweat testing for cystic fibrosis.

    PubMed

    Collie, Jake T B; Massie, R John; Jones, Oliver A H; LeGrys, Vicky A; Greaves, Ronda F

    2014-02-01

    The sweat test remains important as a diagnostic test for cystic fibrosis (CF) and has contributed greatly to our understanding of CF as a disease of epithelial electrolyte transport. The standardization of the sweat test, by Gibson and Cooke [Gibson and Cooke (1959) Pediatrics 1959;23:5], followed observations of excessive dehydration amongst patients with CF and confirmed the utility as a diagnostic test. Quantitative pilocarpine iontophoresis remains the gold standard for sweat induction, but there are a number of collection and analytical methods. The pathophysiology of electrolyte transport in sweat was described by Quinton [Quinton (1983) Nature 1983;301:421-422], and this complemented the developments in genetics that discovered the cystic fibrosis transmembrane conductance regulator (CFTR), an epithelial-based electrolyte transport protein. Knowledge of CF has since increased rapidly and further developments in sweat testing include: new collection methods, further standardization of the technique with international recommendations and age related reference intervals. More recently, sweat chloride values have been used as proof of effect for the new drugs that activate CFTR. However, there remain issues with adherence to sweat test guidelines in many countries and there are gaps in our knowledge, including reference intervals for some age groups and stability of sweat samples in transport. Furthermore, modern methods of elemental quantification need to be explored as alternatives to the original analytical methods for sweat electrolyte measurement. The purpose of this review is therefore to describe the development of the sweat test and consider future directions. © 2013 Wiley Periodicals, Inc.

  12. Nanomolar Trace Metal Analysis of Copper at Gold Microband Arrays

    NASA Astrophysics Data System (ADS)

    Wahl, A.; Dawson, K.; Sassiat, N.; Quinn, A. J.; O'Riordan, A.

    2011-08-01

    This paper describes the fabrication and electrochemical characterization of gold microband electrode arrays designated as a highly sensitive sensor for trace metal detection of copper in drinking water samples. Gold microband electrodes have been routinely fabricated by standard photolithographic methods. Electrochemical characterization were conducted in 0.1 M H2SO4 and found to display characteristic gold oxide formation and reduction peaks. The advantages of gold microband electrodes as trace metal sensors over currently used methods have been investigated by employing under potential deposition anodic stripping voltammetry (UPD-ASV) in Cu2+ nanomolar concentrations. Linear correlations were observed for increasing Cu2+ concentrations from which the concentration of an unknown sample of drinking water was estimated. The results obtained for the estimation of the unknown trace copper concentration in drinking was in good agreement with expected values.

  13. Estimating disease prevalence in two-phase studies.

    PubMed

    Alonzo, Todd A; Pepe, Margaret Sullivan; Lumley, Thomas

    2003-04-01

    Disease prevalence is ideally estimated using a 'gold standard' to ascertain true disease status on all subjects in a population of interest. In practice, however, the gold standard may be too costly or invasive to be applied to all subjects, in which case a two-phase design is often employed. Phase 1 data consisting of inexpensive and non-invasive screening tests on all study subjects are used to determine the subjects that receive the gold standard in the second phase. Naive estimates of prevalence in two-phase studies can be biased (verification bias). Imputation and re-weighting estimators are often used to avoid this bias. We contrast the forms and attributes of the various prevalence estimators. Distribution theory and simulation studies are used to investigate their bias and efficiency. We conclude that the semiparametric efficient approach is the preferred method for prevalence estimation in two-phase studies. It is more robust and comparable in its efficiency to imputation and other re-weighting estimators. It is also easy to implement. We use this approach to examine the prevalence of depression in adolescents with data from the Great Smoky Mountain Study.

  14. When do latent class models overstate accuracy for diagnostic and other classifiers in the absence of a gold standard?

    PubMed

    Spencer, Bruce D

    2012-06-01

    Latent class models are increasingly used to assess the accuracy of medical diagnostic tests and other classifications when no gold standard is available and the true state is unknown. When the latent class is treated as the true class, the latent class models provide measures of components of accuracy including specificity and sensitivity and their complements, type I and type II error rates. The error rates according to the latent class model differ from the true error rates, however, and empirical comparisons with a gold standard suggest the true error rates often are larger. We investigate conditions under which the true type I and type II error rates are larger than those provided by the latent class models. Results from Uebersax (1988, Psychological Bulletin 104, 405-416) are extended to accommodate random effects and covariates affecting the responses. The results are important for interpreting the results of latent class analyses. An error decomposition is presented that incorporates an error component from invalidity of the latent class model. © 2011, The International Biometric Society.

  15. Joint model for a diagnostic test without a gold standard in the presence of a dependent terminal event.

    PubMed

    Luo, Sheng; Su, Xiao; DeSantis, Stacia M; Huang, Xuelin; Yi, Min; Hunt, Kelly K

    2014-07-10

    Breast cancer patients after breast conservation therapy often develop ipsilateral breast tumor relapse (IBTR), whose classification (true local recurrence versus new ipsilateral primary tumor) is subject to error, and there is no available gold standard. Some patients may die because of breast cancer before IBTR develops. Because this terminal event may be related to the individual patient's unobserved disease status and time to IBTR, the terminal mechanism is non-ignorable. This article presents a joint analysis framework to model the binomial regression with misclassified binary outcome and the correlated time to IBTR, subject to a dependent terminal event and in the absence of a gold standard. Shared random effects are used to link together two survival times. The proposed approach is evaluated by a simulation study and is applied to a breast cancer data set consisting of 4477 breast cancer patients. The proposed joint model can be conveniently fit using adaptive Gaussian quadrature tools implemented in SAS 9.3 (SAS Institute Inc., Cary, NC, USA) procedure NLMIXED. Copyright © 2014 John Wiley & Sons, Ltd.

  16. Diagnostic accuracy of tuberculous lymphadenitis fine needle aspiration biopsy confirmed by PCR as gold standard

    NASA Astrophysics Data System (ADS)

    DSuryadi; Delyuzar; Soekimin

    2018-03-01

    Indonesia is the second country with the TB (tuberculosis) burden in the world. Improvement in controlling TB and reducing the complications can accelerate early diagnosis and correct treatment. PCR test is a gold standard. However, it is quite expensive for routine diagnosis. Therefore, an accurate and cheaper diagnostic method such as fine needle aspiration biopsy is needed. The study aimsto determine the accuracy of fine needle aspiration biopsy cytology in the diagnosis of tuberculous lymphadenitis. A cross-sectional analytic study was conducted to the samples from patients suspected with tuberculous lymphadenitis. The fine needle aspiration biopsy (FNAB)test was performed and confirmed by PCR test.There is a comparison to the sensitivity, specificity, accuracy, positive predictive value and negative predictive value of both methods. Sensitivity (92.50%), specificity (96.49%), accuracy (94.85%), positive predictive value (94.87%) and negative predictive value (94.83%) were in FNAB test compared to gold standard. We concluded that fine needle aspiration biopsy is a recommendation for a cheaper and accurate diagnostic test for tuberculous lymphadenitis diagnosis.

  17. Characterization of Ricin and R. communis Agglutinin Reference Materials.

    PubMed

    Worbs, Sylvia; Skiba, Martin; Söderström, Martin; Rapinoja, Marja-Leena; Zeleny, Reinhard; Russmann, Heiko; Schimmel, Heinz; Vanninen, Paula; Fredriksson, Sten-Åke; Dorner, Brigitte G

    2015-11-26

    Ricinus communis intoxications have been known for centuries and were attributed to the toxic protein ricin. Due to its toxicity, availability, ease of preparation, and the lack of medical countermeasures, ricin attracted interest as a potential biological warfare agent. While different technologies for ricin analysis have been established, hardly any universally agreed-upon "gold standards" are available. Expert laboratories currently use differently purified in-house materials, making any comparison of accuracy and sensitivity of different methods nearly impossible. Technically challenging is the discrimination of ricin from R. communis agglutinin (RCA120), a less toxic but highly homologous protein also contained in R. communis. Here, we established both highly pure ricin and RCA120 reference materials which were extensively characterized by gel electrophoresis, liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI MS/MS), and matrix-assisted laser desorption ionization-time of flight approaches as well as immunological and functional techniques. Purity reached >97% for ricin and >99% for RCA120. Different isoforms of ricin and RCA120 were identified unambiguously and distinguished by LC-ESI MS/MS. In terms of function, a real-time cytotoxicity assay showed that ricin is approximately 300-fold more toxic than RCA120. The highly pure ricin and RCA120 reference materials were used to conduct an international proficiency test.

  18. Multiple metals exposure in a small-scale artisanal gold mining community.

    PubMed

    Basu, Niladri; Nam, Dong-Ha; Kwansaa-Ansah, Edward; Renne, Elisha P; Nriagu, Jerome O

    2011-04-01

    Urinary metals were characterized in 57 male residents of a small-scale gold mining community in Ghana. Chromium and arsenic exceeded health guideline values for 52% and 34%, respectively, of all participants. About 10-40% of the participants had urinary levels of aluminum, copper, manganese, nickel, selenium, and zinc that fell outside the U.S. reference range. Exposures appear ubiquitous across the community as none of the elements were associated with occupation, age, and diet. Copyright © 2011 Elsevier Inc. All rights reserved.

  19. Interaction of Electromagnetic Fields with Magnetized Plasmas

    DTIC Science & Technology

    1994-03-31

    ref. 1) and by Golde 3 (ref. 2). Two additional books, entirely on the subject of ball lightning, have been written by Singer (ref. 3) and by Barry...References 1. Martin A. Uman: Lightning, McGraw Hill Book Co. New York, N2Y. (1969), pp. £ 243-248. 2. R. H. Golde , Editor: Lightning: Vol. I. Physics of...ratio& moans with 9. A microwave aborpt ~on system. as defined in said varying .84118W field and absorb smid micro. claim X. wheretin said microwave

  20. Exploring variation-aware contig graphs for (comparative) metagenomics using MaryGold

    PubMed Central

    Nijkamp, Jurgen F.; Pop, Mihai; Reinders, Marcel J. T.; de Ridder, Dick

    2013-01-01

    Motivation: Although many tools are available to study variation and its impact in single genomes, there is a lack of algorithms for finding such variation in metagenomes. This hampers the interpretation of metagenomics sequencing datasets, which are increasingly acquired in research on the (human) microbiome, in environmental studies and in the study of processes in the production of foods and beverages. Existing algorithms often depend on the use of reference genomes, which pose a problem when a metagenome of a priori unknown strain composition is studied. In this article, we develop a method to perform reference-free detection and visual exploration of genomic variation, both within a single metagenome and between metagenomes. Results: We present the MaryGold algorithm and its implementation, which efficiently detects bubble structures in contig graphs using graph decomposition. These bubbles represent variable genomic regions in closely related strains in metagenomic samples. The variation found is presented in a condensed Circos-based visualization, which allows for easy exploration and interpretation of the found variation. We validated the algorithm on two simulated datasets containing three respectively seven Escherichia coli genomes and showed that finding allelic variation in these genomes improves assemblies. Additionally, we applied MaryGold to publicly available real metagenomic datasets, enabling us to find within-sample genomic variation in the metagenomes of a kimchi fermentation process, the microbiome of a premature infant and in microbial communities living on acid mine drainage. Moreover, we used MaryGold for between-sample variation detection and exploration by comparing sequencing data sampled at different time points for both of these datasets. Availability: MaryGold has been written in C++ and Python and can be downloaded from http://bioinformatics.tudelft.nl/software Contact: d.deridder@tudelft.nl PMID:24058058

  1. Laser-driven shock compression of gold foam in the terapascal pressure range

    NASA Astrophysics Data System (ADS)

    Liu, Wei; Duan, Xiaoxi; Jiang, Shaoen; Wang, Zhebin; Sun, Liang; Liu, Hao; Yang, Weiming; Zhang, Huan; Ye, Qing; Wang, Peng; Li, Yulong; Yi, Lin; Dong, Suo

    2018-06-01

    Shock compression experiments are carried out on gold foam with an initial density of 3.2 g/cm3 through indirectly laser-driven shock waves at the SG-III prototype laser facility. The impedance-matching technique is applied to determine the equation-of-state (EOS) data of the shocked gold foam. A passive shock breakout diagnostic system is employed to obtain the shock velocities in both the standard material and gold foam. The gold foams are compressed to a maximum density of 20 g/cm3 under a shock pressure of about 2 TPa. The effects of the unsteadiness of shock waves on the EOS measurement are quantitatively analyzed and corrected. The correction of unsteady waves, as well as the good planarity of the shock waves and the low preheating of the gold foam, contributes high-confidence EOS data for the gold foam. The corrected experimental data are compared with the Hugoniot states from the SESAME library. The comparison suggests that the database is suitable for describing the states of gold foam with an initial density of 3.2 g/cm3 under a pressure of about 2 TPa.

  2. Gold--a controversial sensitizer. European Environmental and Contact Dermatitis Research Group.

    PubMed

    Bruze, M; Andersen, K E

    1999-06-01

    Until recently, gold allergy was considered to be extremely rare. Gold has been used and worshipped for thousands of years without any obvious complaints of skin problems, either in those participating in mining and other ways of prospecting, or in those wearing jewellery. When studies on contact allergy to gold sodium thiosulfate were published at the beginning of the 1990s, the allergic nature of the reported positive patch test reactions to gold was questioned. The major argument for such questioning was the lack of demonstrable clinical relevance in most positive reactors. A major reason for the questioning may have been confusion in differentiating between contact allergy and allergic contact dermatitis. To arrive at a diagnosis of allergic contact dermatitis, 3 steps have, in principle, to be fulfilled: (i) establishment of contact allergy; (ii) demonstration of present exposure; (iii) assessment of clinical relevance, i.e., causing or aggravating a contact dermatitis. In this paper, these steps are discussed with regard to gold. With our present knowledge of contact allergy-allergic contact dermatitis, we do not recommend including gold sodium thiosulfate in the standard series. It should be applied for scientific purposes and when allergic contact dermatitis from gold is suspected.

  3. Gold in natural water: A method of determination by solvent extraction and electrothermal atomization

    USGS Publications Warehouse

    McHugh, J.B.

    1984-01-01

    A method has been developed using electrothermal atomization to effectively determine the amount of gold in natural water within the nanogram range. The method has four basic steps: (1) evaporating a 1-L sample; (2) putting it in hydrobromic acid-bromine solution; (3) extracting the sample with methyl-isobutyl-ketone; and (4) determining the amount of gold using an atomic absorption spectrophotometer. The limit of detection is 0.001 ??g gold per liter. Results from three studies indicate, respectively, that the method is precise, effective, and free of interference. Specifically, a precision study indicates that the method has a relative standard deviation of 16-18%; a recovery study indicates that the method recovers gold at an average of 93%; and an interference study indicates that the interference effects are eliminated with solvent extraction and background correction techniques. Application of the method to water samples collected from 41 sites throughout the Western United States and Alaska shows a gold concentration range of < 0.001 to 0.036 ??g gold per liter, with an average of 0.005 ??g/L. ?? 1984.

  4. Bottom-up formation of robust gold carbide

    PubMed Central

    Westenfelder, Benedikt; Biskupek, Johannes; Meyer, Jannik C.; Kurasch, Simon; Lin, Xiaohang; Scholz, Ferdinand; Gross, Axel; Kaiser, Ute

    2015-01-01

    A new phenomenon of structural reorganization is discovered and characterized for a gold-carbon system by in-situ atomic-resolution imaging at temperatures up to 1300 K. Here, a graphene sheet serves in three ways, as a quasi transparent substrate for aberration-corrected high-resolution transmission electron microscopy, as an in-situ heater, and as carbon supplier. The sheet has been decorated with gold nanoislands beforehand. During electron irradiation at 80 kV and at elevated temperatures, the accumulation of gold atoms has been observed on defective graphene sites or edges as well as at the facets of gold nanocrystals. Both resulted in clustering, forming unusual crystalline structures. Their lattice parameters and surface termination differ significantly from standard gold nanocrystals. The experimental data, supported by electron energy loss spectroscopy and density-functional theory calculations, suggests that isolated gold and carbon atoms form – under conditions of heat and electron irradiation – a novel type of compound crystal, Au-C in zincblende structure. The novel material is metastable, but surprisingly robust, even under annealing condition. PMID:25772348

  5. 45 CFR 156.400 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... to the requirements of § 156.130(a). A standard plan at the bronze, silver, gold, or platinum level..., and a standard platinum plan, respectively. Zero cost sharing plan variation means, with respect to a...

  6. Long-term Follow-up of a Case of Gold Shunt Surgery for Refractory Silicone Oil–induced Glaucoma

    PubMed Central

    Le, Ryan; Berger, Alan R.

    2016-01-01

    Purpose: To report the first case of gold shunt surgery for treatment of silicone oil–induced refractory glaucoma in a tertiary care academic center, with 5-year follow-up. Design: The study design is a case report. Participants: The participant was a patient who underwent gold shunt surgery. Methods: Institutional Research Ethics Board approval for the study was obtained. A diabetic patient was referred for refractory glaucoma with a history of proliferative diabetic retinal detachment, and surgery with silicone oil. She was uncontrolled on maximal medical therapy and following informed consent, gold shunt surgery was performed. Ocular outcomes and number of medications were reviewed over a 5-year period. Results: Following uncomplicated surgery, intraocular pressure was reduced from 41 to 14 mm Hg, and the number of medications was reduced from 4 to 1. Glaucomatous optic neuropathy remained stable. Conclusions: Gold shunt surgery in this challenging case of silicone oil refractory glaucoma provided long-term intraocular pressure control and reduced need for medication over a 5-year period. PMID:27253968

  7. Progression-free survival: gaining on overall survival as a gold standard and accelerating drug development.

    PubMed

    Lebwohl, David; Kay, Andrea; Berg, William; Baladi, Jean Francois; Zheng, Ji

    2009-01-01

    In clinical trials of oncology drugs, overall survival (OS) is a direct measure of clinical efficacy and is considered the gold standard primary efficacy end point. The purpose of this study was to discuss the difficulties in using OS as a primary efficacy end point in the setting of evolving cancer therapies. We suggest that progression-free survival is an appropriate efficacy end point in many types of cancer, specifically those for which OS is expected to be prolonged and for which subsequent treatments are expected to affect OS.

  8. Imaging of the optic disk in caring for patients with glaucoma: ophthalmoscopy and photography remain the gold standard.

    PubMed

    Spaeth, George L; Reddy, Swathi C

    2014-01-01

    Optic disk imaging is integral to the diagnosis and treatment of patients with glaucoma. We discuss the various forms of imaging the optic nerve, including ophthalmoscopy, photography, and newer imaging modalities, including optical coherence tomography (OCT), confocal scanning laser ophthalmoscopy (HRT), and scanning laser polarimetry (GDx), specifically highlighting their benefits and disadvantages. We argue that ophthalmoscopy and photography remain the gold standard of imaging due to portability, ease of interpretation, and the presence of a large database of images for comparison. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Breast-feeding, bottle-feeding and Dr. Spock: the shifting context of choice.

    PubMed

    Knaak, Stephanie

    2005-05-01

    In today's environment, breast-feeding represents both a medical gold standard for infant feeding and a moral gold standard for mothering. The morally charged character of this discourse makes the notion of choice in infant feeding particularly problematic and fraught with difficulty. From an historical content analysis of selected editions from 1946 to 1998 of Dr. Spock's famous child-care manual, this paper explicates the process through which the breast versus bottle discourse has shifted over the last half-century, and how these shifts have shaped the context of choice within which mothers must make their infant-feeding decisions.

  10. Interstitial laser coagulation of benign prostatic hyperplasia: a minimally invasive treatment alternative

    NASA Astrophysics Data System (ADS)

    Ordonez, Robert F.; Mittemeyer, Bernhard T.; Aronoff, David R.; de Riese, Werner T. W.

    2003-06-01

    The use of minimally invasive treatments for benign prostatic hyperplasia (BPH) have been introduced into the medical community. Over the last decade several minimally invasive treatment techniques have been approved for use. In particular, interstitial laser coagulation (ILC) has shown pomise as an alternative to the current gold standard, transurethral resection of prostate (TURP). Studies show ILC to have equal efficacy as TURP while causing less side effects. Future technical advances as well as increased physician experience with ILC could lead to the replacement of TURP as the gold standard in trestment of BPH.

  11. 76 FR 73752 - Self-Regulatory Organizations; Options Clearing Corporation; Notice of Filing of Amendment No. 2...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-29

    ... measure the relative total returns of a stock or exchange-traded fund (``ETF'') against another stock or ETF, including where one of the reference ETFs measured by the index is a gold- or silver-based ETF.\\4... reference securities of an underlying relative performance index is an ETF designed to measure the return of...

  12. In situ SIMS U-Pb dating of hydrothermal rutile: reliable age for the Zhesang Carlin-type gold deposit in the golden triangle region, SW China

    NASA Astrophysics Data System (ADS)

    Pi, Qiaohui; Hu, Ruizhong; Xiong, Bin; Li, Qiuli; Zhong, Richen

    2017-12-01

    The contiguous region between Guangxi, Guizhou, and Yunnan, commonly referred to as the Golden Triangle region in SW China, hosts many Carlin-type gold deposits. Previously, the ages of the gold mineralization in this region have not been well constrained due to the lack of suitable minerals for radiometric dating. This paper reports the first SIMS U-Pb age of hydrothermal rutile crystals for the Zhesang Carlin-type gold deposit in the region. The hydrothermal U-bearing rutile associated with gold-bearing sulfides in the deposit yields an U-Pb age of 213.6 ± 5.4 Ma, which is within the range of the previously reported arsenopyrite Re-Os isochron ages (204 ± 19 to 235 ± 33 Ma) for three other Carlin-type gold deposits in the region. Our new and more precise rutile U-Pb age confirms that the gold mineralization was contemporaneous with the Triassic W-Sn mineralization and associated granitic magmatism in the surrounding regions. Based on the temporal correlation, we postulate that coeval granitic plutons may be present at greater depths in the Golden Triangle region and that the formation of the Carlin-type gold deposits is probably linked to the coeval granitic magmatism in the region. This study clearly demonstrates that in situ rutile U-Pb dating is a robust tool for the geochronogical study of hydrothermal deposits that contain hydrothermal rutile.

  13. Association between all-cause and cause-specific mortality and the GOLD stages 1-4: A 30-year follow-up among Finnish adults.

    PubMed

    Mattila, Tiina; Vasankari, Tuula; Kanervisto, Merja; Laitinen, Tarja; Impivaara, Olli; Rissanen, Harri; Knekt, Paul; Jousilahti, Pekka; Saarelainen, Seppo; Puukka, Pauli; Heliövaara, Markku

    2015-08-01

    Mortality correlates with the Global Initiative for Chronic Obstructive Lung Disease (GOLD) criteria of airway obstruction. Yet, little data exist concerning the long-term survival of patients presenting with different levels of obstruction. We studied the association between all-cause and cause-specific mortality and GOLD stages 1-4 in a 30-year follow-up among 6636 Finnish men and women aged 30 or older participating in the Mini-Finland Health Study between 1978 and 1980. After adjusting for age, sex, and smoking history, the GOLD stage of the subject showed a strong direct relationship with all-cause mortality, mortality from cardiovascular and respiratory diseases, and cancer. The adjusted hazard ratios of death were 1.27 (95% confidence interval (CI) 1.06-1.51), 1.40 (1.21-1.63), 1.55 (1.21-1.97) and 2.85 (1.65-4.94) for GOLD stages 1-4, respectively, with FEV1/FVC ≥70% as the reference. The association between GOLD stages 2-4 and mortality was strongest among subjects under 50 years of age at the baseline measurement. Cardiovascular mortality increased consistently for all GOLD stages. Airway obstruction indicates an increased risk for all-cause mortality according to the severity of the GOLD stage. We found that even stage 1 carries a risk for cardiovascular death independently of smoking history and other known risk factors. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. High-Accuracy HLA Type Inference from Whole-Genome Sequencing Data Using Population Reference Graphs.

    PubMed

    Dilthey, Alexander T; Gourraud, Pierre-Antoine; Mentzer, Alexander J; Cereb, Nezih; Iqbal, Zamin; McVean, Gil

    2016-10-01

    Genetic variation at the Human Leucocyte Antigen (HLA) genes is associated with many autoimmune and infectious disease phenotypes, is an important element of the immunological distinction between self and non-self, and shapes immune epitope repertoires. Determining the allelic state of the HLA genes (HLA typing) as a by-product of standard whole-genome sequencing data would therefore be highly desirable and enable the immunogenetic characterization of samples in currently ongoing population sequencing projects. Extensive hyperpolymorphism and sequence similarity between the HLA genes, however, pose problems for accurate read mapping and make HLA type inference from whole-genome sequencing data a challenging problem. We describe how to address these challenges in a Population Reference Graph (PRG) framework. First, we construct a PRG for 46 (mostly HLA) genes and pseudogenes, their genomic context and their characterized sequence variants, integrating a database of over 10,000 known allele sequences. Second, we present a sequence-to-PRG paired-end read mapping algorithm that enables accurate read mapping for the HLA genes. Third, we infer the most likely pair of underlying alleles at G group resolution from the IMGT/HLA database at each locus, employing a simple likelihood framework. We show that HLA*PRG, our algorithm, outperforms existing methods by a wide margin. We evaluate HLA*PRG on six classical class I and class II HLA genes (HLA-A, -B, -C, -DQA1, -DQB1, -DRB1) and on a set of 14 samples (3 samples with 2 x 100bp, 11 samples with 2 x 250bp Illumina HiSeq data). Of 158 alleles tested, we correctly infer 157 alleles (99.4%). We also identify and re-type two erroneous alleles in the original validation data. We conclude that HLA*PRG for the first time achieves accuracies comparable to gold-standard reference methods from standard whole-genome sequencing data, though high computational demands (currently ~30-250 CPU hours per sample) remain a significant challenge to practical application.

  15. High-Accuracy HLA Type Inference from Whole-Genome Sequencing Data Using Population Reference Graphs

    PubMed Central

    Dilthey, Alexander T.; Gourraud, Pierre-Antoine; McVean, Gil

    2016-01-01

    Genetic variation at the Human Leucocyte Antigen (HLA) genes is associated with many autoimmune and infectious disease phenotypes, is an important element of the immunological distinction between self and non-self, and shapes immune epitope repertoires. Determining the allelic state of the HLA genes (HLA typing) as a by-product of standard whole-genome sequencing data would therefore be highly desirable and enable the immunogenetic characterization of samples in currently ongoing population sequencing projects. Extensive hyperpolymorphism and sequence similarity between the HLA genes, however, pose problems for accurate read mapping and make HLA type inference from whole-genome sequencing data a challenging problem. We describe how to address these challenges in a Population Reference Graph (PRG) framework. First, we construct a PRG for 46 (mostly HLA) genes and pseudogenes, their genomic context and their characterized sequence variants, integrating a database of over 10,000 known allele sequences. Second, we present a sequence-to-PRG paired-end read mapping algorithm that enables accurate read mapping for the HLA genes. Third, we infer the most likely pair of underlying alleles at G group resolution from the IMGT/HLA database at each locus, employing a simple likelihood framework. We show that HLA*PRG, our algorithm, outperforms existing methods by a wide margin. We evaluate HLA*PRG on six classical class I and class II HLA genes (HLA-A, -B, -C, -DQA1, -DQB1, -DRB1) and on a set of 14 samples (3 samples with 2 x 100bp, 11 samples with 2 x 250bp Illumina HiSeq data). Of 158 alleles tested, we correctly infer 157 alleles (99.4%). We also identify and re-type two erroneous alleles in the original validation data. We conclude that HLA*PRG for the first time achieves accuracies comparable to gold-standard reference methods from standard whole-genome sequencing data, though high computational demands (currently ~30–250 CPU hours per sample) remain a significant challenge to practical application. PMID:27792722

  16. Exercise echocardiography for structural heart disease.

    PubMed

    Izumo, Masaki; Akashi, Yoshihiro J

    2016-03-01

    Since the introduction of transcatheter structural heart intervention, the term "structural heart disease" has been widely used in the field of cardiology. Structural heart disease refers to congenital heart disease, valvular heart disease, and cardiomyopathy. In structural heart disease, valvular heart disease is frequently identified in the elderly. Of note, the number of patients who suffer from aortic stenosis (AS) and mitral regurgitation (MR) is increasing in developed countries because of the aging of the populations. Transcatheter aortic valve replacement and percutaneous mitral valve repair has been widely used for AS and MR, individually. Echocardiography is the gold standard modality for initial diagnosis and subsequent evaluation of AS and MR, although the difficulties in assessing patients with these diseases still remain. Here, we review the clinical usefulness and prognostic impact of exercise echocardiography on structural heart disease, particularly on AS and MR.

  17. [Accuracy of computer aided measurement for detecting dental proximal caries lesions in images of cone-beam computed tomography].

    PubMed

    Zhang, Z L; Li, J P; Li, G; Ma, X C

    2017-02-09

    Objective: To establish and validate a computer program used to aid the detection of dental proximal caries in the images cone beam computed tomography (CBCT) images. Methods: According to the characteristics of caries lesions in X-ray images, a computer aided detection program for proximal caries was established with Matlab and Visual C++. The whole process for caries lesion detection included image import and preprocessing, measuring average gray value of air area, choosing region of interest and calculating gray value, defining the caries areas. The program was used to examine 90 proximal surfaces from 45 extracted human teeth collected from Peking University School and Hospital of Stomatology. The teeth were then scanned with a CBCT scanner (Promax 3D). The proximal surfaces of the teeth were respectively detected by caries detection program and scored by human observer for the extent of lesions with 6-level-scale. With histologic examination serving as the reference standard, the caries detection program and the human observer performances were assessed with receiver operating characteristic (ROC) curves. Student t -test was used to analyze the areas under the ROC curves (AUC) for the differences between caries detection program and human observer. Spearman correlation coefficient was used to analyze the detection accuracy of caries depth. Results: For the diagnosis of proximal caries in CBCT images, the AUC values of human observers and caries detection program were 0.632 and 0.703, respectively. There was a statistically significant difference between the AUC values ( P= 0.023). The correlation between program performance and gold standard (correlation coefficient r (s)=0.525) was higher than that of observer performance and gold standard ( r (s)=0.457) and there was a statistically significant difference between the correlation coefficients ( P= 0.000). Conclusions: The program that automatically detects dental proximal caries lesions could improve the diagnostic value of CBCT images.

  18. Comparison of validity of mapping between drug indications and ICD-10. Direct and indirect terminology based approaches.

    PubMed

    Choi, Y; Jung, C; Chae, Y; Kang, M; Kim, J; Joung, K; Lim, J; Cho, S; Sung, S; Lee, E; Kim, S

    2014-01-01

    Mapping of drug indications to ICD-10 was undertaken in Korea by a public and a private institution for their own purposes. A different mapping approach was used by each institution, which presented a good opportunity to compare the validity of the two approaches. This study was undertaken to compare the validity of a direct mapping approach and an indirect terminology based mapping approach of drug indications against the gold standard drawn from the results of the two mapping processes. Three hundred and seventy-five cardiovascular reference drugs were selected from all listed cardiovascular drugs for the study. In the direct approach, two experienced nurse coders mapped the free text indications directly to ICD-10. In the indirect terminology based approach, the indications were extracted and coded in the Korean Standard Terminology of Medicine. These terminology coded indications were then manually mapped to ICD-10. The results of the two approaches were compared to the gold standard. A kappa statistic was calculated to see the compatibility of both mapping approaches. Recall, precision and F1 score of each mapping approach were calculated and analyzed using a paired t-test. The mean number of indications for the study drugs was 5.42. The mean number of ICD-10 codes that matched in direct approach was 46.32 and that of indirect terminology based approach was 56.94. The agreement of the mapping results between the two approaches were poor (kappa = 0.19). The indirect terminology based approach showed higher recall (86.78%) than direct approach (p < 0.001). However, there was no difference in precision and F1 score between the two approaches. Considering no differences in the F1 scores, both approaches may be used in practice for mapping drug indications to ICD-10. However, in terms of consistency, time and manpower, better results are expected from the indirect terminology based approach.

  19. A new method to address verification bias in studies of clinical screening tests: cervical cancer screening assays as an example.

    PubMed

    Xue, Xiaonan; Kim, Mimi Y; Castle, Philip E; Strickler, Howard D

    2014-03-01

    Studies to evaluate clinical screening tests often face the problem that the "gold standard" diagnostic approach is costly and/or invasive. It is therefore common to verify only a subset of negative screening tests using the gold standard method. However, undersampling the screen negatives can lead to substantial overestimation of the sensitivity and underestimation of the specificity of the diagnostic test. Our objective was to develop a simple and accurate statistical method to address this "verification bias." We developed a weighted generalized estimating equation approach to estimate, in a single model, the accuracy (eg, sensitivity/specificity) of multiple assays and simultaneously compare results between assays while addressing verification bias. This approach can be implemented using standard statistical software. Simulations were conducted to assess the proposed method. An example is provided using a cervical cancer screening trial that compared the accuracy of human papillomavirus and Pap tests, with histologic data as the gold standard. The proposed approach performed well in estimating and comparing the accuracy of multiple assays in the presence of verification bias. The proposed approach is an easy to apply and accurate method for addressing verification bias in studies of multiple screening methods. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Genetics Home Reference: Weaver syndrome

    MedlinePlus

    ... slightly increased risk of developing a tumor called neuroblastoma in early childhood, but the small number of ... Coulter D, Powell CM, Gold S. Weaver syndrome and neuroblastoma. J Pediatr Hematol Oncol. 2008 Oct;30(10): ...

  1. Alice Paul Congressional Gold Medal Act

    THOMAS, 112th Congress

    Sen. Menendez, Robert [D-NJ

    2011-10-20

    Senate - 10/20/2011 Read twice and referred to the Committee on Banking, Housing, and Urban Affairs. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:

  2. Alice Paul Congressional Gold Medal Act

    THOMAS, 113th Congress

    Sen. Menendez, Robert [D-NJ

    2013-03-05

    Senate - 03/05/2013 Read twice and referred to the Committee on Banking, Housing, and Urban Affairs. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:

  3. Pat Summitt Congressional Gold Medal Act

    THOMAS, 113th Congress

    Sen. Alexander, Lamar [R-TN

    2014-01-09

    Senate - 01/09/2014 Read twice and referred to the Committee on Banking, Housing, and Urban Affairs. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:

  4. Regional baseline geochemistry and environmental effects of gold placer mining operations on the Fortymile River, eastern Alaska: A section in Geologic studies in Alaska by the U.S. Geological Survey, 1998

    USGS Publications Warehouse

    Wanty, Richard B.; Wang, Bronwen; Vohden, Jim; Briggs, Paul H.; Meier, Allen L.

    2000-01-01

    A systematic water-quality study of the Fortymile River and many of its major tributaries in eastern Alaska was conducted in June of 1997 and 1998. Surface-water samples were collected for chemical analyses to establish regional baseline geochemistry values and to evaluate the possible environmental effects of suction-dredge placer gold mining and bulldozer-operated placer gold mining (commonly referred to as “cat mining”). In general, the water quality of the Fortymile River is very good, with low total dissolved solids and only two cases in which the concentration of any element exceeded primary or secondary drinking-water quality standards. In both cases, iron exceeded secondary drinking-water limits. At the time this work was conducted, only a handful of suction dredges were operating on the lower Fortymile River, and cat mining was being conducted along Uhler Creek and Canyon Creek, two major tributaries to the river. Based on the water-quality and turbidity data, the suction dredges have no apparent impact on the Fortymile River system, although possible effects on biota have not been evaluated in this study. In contrast, the cat-mining operations in Canyon Creek appear to have a dramatic impact on water quality and stream-bed morphology, based on the field water-quality and turbidity measurements, on comparisons to adjacent unmined drainages, and on field observations of stream-bed morphology. The cat mining in Uhler Creek appears to have had less impact, perhaps because the main stream channel was not as heavily disrupted by the bulldozers, and the stability of the channel was mostly preserved.

  5. Robot assisted radical prostatectomy: current concepts.

    PubMed

    Sairam, K; Dasgupta, P

    2009-06-01

    Laparoscopic cholecystectomy has evolved from being a reluctantly accepted novelty to the most widely adopted procedure. It reached a high popularity even before randomized trials could be carried out. Open cholecystectomy was at one time considered the ''gold standard'', only to be replaced by laparoscopic cholecystectomy. Today the same is happening with radical prostatectomy. Open radical prostatectomy (ORP) was the reference standard. Afterwards, came laparoscopic radical prostatectomy (LRP), which matched ORP in terms of the trifecta of oncological, continence and sexual function outcomes. Robot-assisted radical prostatectomy (RARP) was the next step in the evolution. Since 2000, it has become very widespread because of private practice promotion among surgeons and marketing hype by the manufacturers. Furthermore, patients ask for this operation. In the last eight years, there has been a rise in conceptual changes, especially in operative techniques, to improve outcomes following RARP. This review will focus on some of the key concepts emerged in the field of robotic surgery, to improve outcomes following RARP. The lack of randomized controlled trials makes it difficult to make true comparisons with ORP, LRP and other methods of treating localized prostate cancer.

  6. Protein and oil composition predictions of single soybeans by transmission Raman spectroscopy.

    PubMed

    Schulmerich, Matthew V; Walsh, Michael J; Gelber, Matthew K; Kong, Rong; Kole, Matthew R; Harrison, Sandra K; McKinney, John; Thompson, Dennis; Kull, Linda S; Bhargava, Rohit

    2012-08-22

    The soybean industry requires rapid, accurate, and precise technologies for the analyses of seed/grain constituents. While the current gold standard for nondestructive quantification of economically and nutritionally important soybean components is near-infrared spectroscopy (NIRS), emerging technology may provide viable alternatives and lead to next generation instrumentation for grain compositional analysis. In principle, Raman spectroscopy provides the necessary chemical information to generate models for predicting the concentration of soybean constituents. In this communication, we explore the use of transmission Raman spectroscopy (TRS) for nondestructive soybean measurements. We show that TRS uses the light scattering properties of soybeans to effectively homogenize the heterogeneous bulk of a soybean for representative sampling. Working with over 1000 individual intact soybean seeds, we developed a simple partial least-squares model for predicting oil and protein content nondestructively. We find TRS to have a root-mean-standard error of prediction (RMSEP) of 0.89% for oil measurements and 0.92% for protein measurements. In both calibration and validation sets, the predicative capabilities of the model were similar to the error in the reference methods.

  7. Subtype Diagnosis of Primary Aldosteronism: Is Adrenal Vein Sampling Always Necessary?

    PubMed Central

    Buffolo, Fabrizio; Monticone, Silvia; Williams, Tracy A.; Rossato, Denis; Burrello, Jacopo; Tetti, Martina; Veglio, Franco; Mulatero, Paolo

    2017-01-01

    Aldosterone producing adenoma and bilateral adrenal hyperplasia are the two most common subtypes of primary aldosteronism (PA) that require targeted and distinct therapeutic approaches: unilateral adrenalectomy or lifelong medical therapy with mineralocorticoid receptor antagonists. According to the 2016 Endocrine Society Guideline, adrenal venous sampling (AVS) is the gold standard test to distinguish between unilateral and bilateral aldosterone overproduction and therefore, to safely refer patients with PA to surgery. Despite significant advances in the optimization of the AVS procedure and the interpretation of hormonal data, a standardized protocol across centers is still lacking. Alternative methods are sought to either localize an aldosterone producing adenoma or to predict the presence of unilateral disease and thereby substantially reduce the number of patients with PA who proceed to AVS. In this review, we summarize the recent advances in subtyping PA for the diagnosis of unilateral and bilateral disease. We focus on the developments in the AVS procedure, the interpretation criteria, and comparisons of the performance of AVS with the alternative methods that are currently available. PMID:28420172

  8. A profilometry-based dentifrice abrasion Method for V8 brushing machines. Part I: Introduction to RDA-PE.

    PubMed

    White, Donald J; Schneiderman, Eva; Colón, Ellen; St John, Samuel

    2015-01-01

    This paper describes the development and standardization of a profilometry-based method for assessment of dentifrice abrasivity called Radioactive Dentin Abrasivity - Profilometry Equivalent (RDA-PE). Human dentine substrates are mounted in acrylic blocks of precise standardized dimensions, permitting mounting and brushing in V8 brushing machines. Dentin blocks are masked to create an area of "contact brushing." Brushing is carried out in V8 brushing machines and dentifrices are tested as slurries. An abrasive standard is prepared by diluting the ISO 11609 abrasivity reference calcium pyrophosphate abrasive into carboxymethyl cellulose/glycerin, just as in the RDA method. Following brushing, masked areas are removed and profilometric analysis is carried out on treated specimens. Assessments of average abrasion depth (contact or optical profilometry) are made. Inclusion of standard calcium pyrophosphate abrasive permits a direct RDA equivalent assessment of abrasion, which is characterized with profilometry as Depth test/Depth control x 100. Within the test, the maximum abrasivity standard of 250 can be created in situ simply by including a treatment group of standard abrasive with 2.5x number of brushing strokes. RDA-PE is enabled in large part by the availability of easy-to-use and well-standardized modern profilometers, but its use in V8 brushing machines is enabled by the unique specific conditions described herein. RDA-PE permits the evaluation of dentifrice abrasivity to dentin without the requirement of irradiated teeth and infrastructure for handling them. In direct comparisons, the RDA-PE method provides dentifrice abrasivity assessments comparable to the gold industry standard RDA technique.

  9. A Validation of an Intelligent Decision-Making Support System for the Nutrition Diagnosis of Bariatric Surgery Patients

    PubMed Central

    Martins, Cristina; Dias, João; Pinto, José S

    2014-01-01

    Background Bariatric surgery is an important method for treatment of morbid obesity. It is known that significant nutritional deficiencies might occur after surgery, such as, calorie-protein malnutrition, iron deficiency anemia, and lack of vitamin B12, thiamine, and folic acid. Objective The objective of our study was to validate a computerized intelligent decision support system that suggests nutritional diagnoses of patients submitted to bariatric surgery. Methods There were fifteen clinical cases that were developed and sent to three dietitians in order to evaluate and define a nutritional diagnosis. After this step, the cases were sent to four bariatric surgery expert dietitians who were aiming to collaborate on a gold standard. The nutritional diagnosis was to be defined individually, and any disagreements were solved through a consensus. The final result was used as the gold standard. Bayesian networks were used to implement the system, and database training was done with Shell Netica. For the system validation, a similar answer rate was calculated, as well as the specificity and sensibility. Receiver operating characteristic (ROC) curves were projected to each nutritional diagnosis. Results Among the four experts, the rate of similar answers found was 80% (48/60) to 93% (56/60), depending on the nutritional diagnosis. The rate of similar answers of the system, compared to the gold standard, was 100% (60/60). The system sensibility and specificity were 95.0%. The ROC curves projection showed that the system was able to represent the expert knowledge (gold standard), and to help them in their daily tasks. Conclusions The system that was developed was validated to be used by health care professionals for decision-making support in their nutritional diagnosis of patients submitted to bariatric surgery. PMID:25601419

  10. A smart all-in-one device to measure vital signs in admitted patients

    PubMed Central

    van Goor, Harry; van Acht, Maartje; van de Belt, Tom H.; Bredie, Sebastian J. H.

    2018-01-01

    Background Vital sign measurements in hospitalized patients by nurses are time consuming and prone to operational errors. The Checkme, a smart all-in-one device capable of measuring vital signs, could improve daily patient monitoring by reducing measurement time, inter-observer variability, and incorrect inputs in the Electronic Health Record (EHR). We evaluated the accuracy of self measurements by patient using the Checkme in comparison with gold standard and nurse measurements. Methods and findings This prospective comparative study was conducted at the Internal Medicine ward of an academic hospital in the Netherlands. Fifty non-critically ill patients were enrolled in the study. Time-related measurement sessions were conducted on consecutive patients in a randomized order: vital sign measurement in duplicate by a well-trained investigator (gold standard), a Checkme measurement by the patient, and a routine vital sign measurement by a nurse. In 41 patients (82%), initial calibration of the Checkme was successful and results were eligible for analysis. In total, 69 sessions were conducted for these 41 patients. The temperature results recorded by the patient with the Checkme differed significantly from the gold standard core temperature measurements (mean difference 0.1 ± 0.3). Obtained differences in vital signs and calculated Modified Early Warning Score (MEWS) were small and were in range with predefined accepted discrepancies. Conclusions Patient-calculated MEWS using the Checkme, nurse measurements, and gold standard measurements all correlated well, and the small differences observed between modalities would not have affected clinical decision making. Using the Checkme, patients in a general medical ward setting are able to measure their own vital signs easily and accurately by themselves. This could be time saving for nurses and prevent errors due to manually entering data in the EHR. PMID:29432461

  11. Tracking the hyoid bone in videofluoroscopic swallowing studies

    NASA Astrophysics Data System (ADS)

    Kellen, Patrick M.; Becker, Darci; Reinhardt, Joseph M.; van Daele, Douglas

    2008-03-01

    Difficulty swallowing, or dysphagia, has become a growing problem. Swallowing complications can lead to malnutrition, dehydration, respiratory infection, and even death. The current gold standard for analyzing and diagnosing dysphagia is the videofluoroscopic barium swallow study. In these studies, a fluoroscope is used to image the patient ingesting barium solutions of different volumes and viscosities. The hyoid bone anchors many key muscles involved in swallowing and plays a key role in the process. Abnormal hyoid bone motion during a swallow can indicate swallowing dysfunction. Currently in clinical settings, hyoid bone motion is assessed qualitatively, which can be subject to intra-rater and inter-rater bias. This paper presents a semi-automatic method for tracking the hyoid bone that makes quantitative analysis feasible. The user defines a template of the hyoid on one frame, and this template is tracked across subsequent frames. The matching phase is optimized by predicting the position of the template based on kinematics. An expert speech pathologist marked the position of the hyoid on each frame of ten studies to serve as the gold standard. Results from performing Bland-Altman analysis at a 95% confidence interval showed a bias of 0.0+/-0.08 pixels in x and -0.08+/-0.09 pixels in y between the manually-defined gold standard and the proposed method. The average Pearson's correlation between the gold standard and the proposed method was 0.987 in x and 0.980 in y. This paper also presents a method for automatically establishing a patient-centric coordinate system for the interpretation of hyoid motion. This coordinate system corrects for upper body patient motion during the study and identifies superior-inferior and anterior-posterior motion components. These tools make the use of quantitative hyoid motion analysis feasible in clinical and research settings.

  12. [Clinical investigation of basophil activation test as a complementary test for house dust mite allergen].

    PubMed

    Ren, H L; Li, J D; Miao, Y H; Xu, T

    2018-03-01

    Objective: To investigate the clinical application of glass micro fiber basophil activation test (BAT) used as a complementary test for house dust mite allergen. Method: Forty patients with clinical diagnosed allergic rhinitis was test by three methods for house dust mite allergen, skin prick test(SPT),Immuno CAP sIgE, and BAT in vitro. The sensitivity and specificity of glass micro fiber were accessed, and the consistency between BAT, SPT, and Immuno sIgE was analyzed. As in vivo provocation was not performed, gold standard is regarded as the combination of medical history and positive reports of SPT and/or ImmunoCAP sIgE test. Result: Twentythree patients are diagnosed as house dust mite allergic rhinitis by gold standard. The sensitivity and specificity of glass micro fiber BAT were 60.9% and 88.2%, the sensitivity of SPT and sIgE was 87.0% and sIgE 73.9%. The correlation rates between BAT with SPT is 0.67( P <0.05), and sIgE 0.55( P <0.05). The accuracy, predictive value of positive and negative of BAT are 0.47,60.9%,88.2%.The Kappa values of BAT, SPT and sIgE with gold standard are 0.47,0.86,0.71. Conclusion: As a complementary test for house dust mite allergic rhinitis, BAT have a good consistency with SPT and sIgE, while as it has only moderate consistency with "gold standard", further studies are needed to prove its clinical significance. Copyright© by the Editorial Department of Journal of Clinical Otorhinolaryngology Head and Neck Surgery.

  13. A smart all-in-one device to measure vital signs in admitted patients.

    PubMed

    Weenk, Mariska; van Goor, Harry; van Acht, Maartje; Engelen, Lucien Jlpg; van de Belt, Tom H; Bredie, Sebastian J H

    2018-01-01

    Vital sign measurements in hospitalized patients by nurses are time consuming and prone to operational errors. The Checkme, a smart all-in-one device capable of measuring vital signs, could improve daily patient monitoring by reducing measurement time, inter-observer variability, and incorrect inputs in the Electronic Health Record (EHR). We evaluated the accuracy of self measurements by patient using the Checkme in comparison with gold standard and nurse measurements. This prospective comparative study was conducted at the Internal Medicine ward of an academic hospital in the Netherlands. Fifty non-critically ill patients were enrolled in the study. Time-related measurement sessions were conducted on consecutive patients in a randomized order: vital sign measurement in duplicate by a well-trained investigator (gold standard), a Checkme measurement by the patient, and a routine vital sign measurement by a nurse. In 41 patients (82%), initial calibration of the Checkme was successful and results were eligible for analysis. In total, 69 sessions were conducted for these 41 patients. The temperature results recorded by the patient with the Checkme differed significantly from the gold standard core temperature measurements (mean difference 0.1 ± 0.3). Obtained differences in vital signs and calculated Modified Early Warning Score (MEWS) were small and were in range with predefined accepted discrepancies. Patient-calculated MEWS using the Checkme, nurse measurements, and gold standard measurements all correlated well, and the small differences observed between modalities would not have affected clinical decision making. Using the Checkme, patients in a general medical ward setting are able to measure their own vital signs easily and accurately by themselves. This could be time saving for nurses and prevent errors due to manually entering data in the EHR.

  14. Evaluation of the Performance of Five Diagnostic Tests for Fasciola hepatica Infection in Naturally Infected Cattle Using a Bayesian No Gold Standard Approach.

    PubMed

    Mazeri, Stella; Sargison, Neil; Kelly, Robert F; Bronsvoort, Barend M deC; Handel, Ian

    2016-01-01

    The clinical and economic importance of fasciolosis has been recognised for centuries, yet diagnostic tests available for cattle are far from perfect. Test evaluation has mainly been carried out using gold standard approaches or under experimental settings, the limitations of which are well known. In this study, a Bayesian no gold standard approach was used to estimate the diagnostic sensitivity and specificity of five tests for fasciolosis in cattle. These included detailed liver necropsy including gall bladder egg count, faecal egg counting, a commercially available copro-antigen ELISA, an in-house serum excretory/secretory antibody ELISA and routine abattoir liver inspection. In total 619 cattle slaughtered at one of Scotland's biggest abattoirs were sampled, during three sampling periods spanning summer 2013, winter 2014 and autumn 2014. Test sensitivities and specificities were estimated using an extension of the Hui Walter no gold standard model, where estimates were allowed to vary between seasons if tests were a priori believed to perform differently for any reason. The results of this analysis provide novel information on the performance of these tests in a naturally infected cattle population and at different times of the year where different levels of acute or chronic infection are expected. Accurate estimates of sensitivity and specificity will allow for routine abattoir liver inspection to be used as a tool for monitoring the epidemiology of F. hepatica as well as evaluating herd health planning. Furthermore, the results provide evidence to suggest that the copro-antigen ELISA does not cross-react with Calicophoron daubneyi rumen fluke parasites, while the serum antibody ELISA does.

  15. 40 CFR 421.256 - Pretreatment standards for new sources.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... for any 1 day Maximum for monthly average mg/troy ounce of gold refined electrolytically Lead 5.544 2... Maximum for monthly average mg/troy ounce of gold and silver smelted Lead 0.364 0.169 Mercury 0.195 0.078... Maximum for monthly average mg/troy ounce of silver reduced in solution Lead 0.112 0.052 Mercury 0.060 0...

  16. 40 CFR 421.256 - Pretreatment standards for new sources.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Maximum for monthly average mg/troy ounce of gold and silver smelted Lead 0.364 0.169 Mercury 0.195 0.078... Maximum for monthly average mg/troy ounce of silver reduced in solution Lead 0.112 0.052 Mercury 0.060 0... for any 1 day Maximum for monthly average mg/troy ounce of gold refined electrolytically Lead 5.544 2...

  17. [Value of combined conventional and contrast enhanced sonography in the evaluation of hepatic disorders].

    PubMed

    Tranquart, F; Bleuzen, A; Kissel, A

    2004-06-01

    To assess the value of combined conventional and contrast-material enhanced sonography for the characterization of focal liver lesions. Simultaneous imaging with grey scale and contrast enhanced US was performed in 90 patients following Levovist injection (Schering, Berlin, Germany) using the "Agent Detection Imaging" method (ADI, Siemens-Acuson, Mountain View, USA). US scanning was performed at least 4 minutes after contrast injection with review of both grayscale and contrast enhanced modes. Results for detection and characterization of lesions were compared to the selected gold standard imaging modality (CT or MRI). Final diagnoses included: 20 normal examinations, 41 patients with metastases, 6 patients with hepatocellular carcinoma, 13 patients with hemangioma, 6 patients with other benign lesions, 4 patients with cysts and 6 patients with two types of lesions. Delayed phase contrast enhanced US allowed diagnosis of all lesions except for one metastasis and all hepatocellular carcinomas. While the diagnosis of hepatoma could not be confirmed, the features suggested a malignant etiology. For 7 patients with metastases, more lesions were detected at ADI (4.9 lesions) than at conventional US (1.1 lesion). For 3 patients, CT showed more lesions than ADI US (3.3 versus 1.6 lesions). The accuracy of ADI US for differentiating between benign and malignant lesions was 98.7% compared to 49.6% for conventional US (p<0.001). The total number of lesions detected at ADI US was higher (p<0.01) than at conventional US and not significantly different from that obtained by the gold standard reference methods. Complete characterization was achieved in 92.2% of cases with ADI US compared to 59.2% with conventional US (p<0.001). Contrast-material enhanced US combined with conventional US markedly improves the diagnostic accuracy of US in terms of lesion detection and characterization.

  18. [Prevalence of Cardiovascular Risk Factors at The Population Level: A Comparison of Ambulatory Physician-Coded Claims Data With Clinical Data From A Population-Based Study].

    PubMed

    Angelow, Aniela; Reber, Katrin Christiane; Schmidt, Carsten Oliver; Baumeister, Sebastian Edgar; Chenot, Jean-Francois

    2018-06-04

    The study assesses the validity of ICD-10 coded cardiovascular risk factors in claims data using gold-standard measurements from a population-based study for arterial hypertension, diabetes, dyslipidemia, smoking and obesity as a reference. Data of 1941 participants (46 % male, mean age 58±13 years) of the Study of Health in Pomerania (SHIP) were linked to electronic medical records from the regional association of statutory health insurance physicians from 2008 to 2012 used for billing purposes. Clinical data from SHIP was used as a gold standard to assess the agreement with claims data for ICD-10 codes I10.- (arterial hypertension), E10.- to E14.- (diabetes mellitus), E78.- (dyslipidemia), F17.- (smoking) and E65.- to E68.- (obesity). A higher agreement between ICD-coded and clinical diagnosis was found for diabetes (sensitivity (sens) 84%, specificity (spec) 95%, positive predictive value (ppv) 80%) and hypertension (sens 72%, spec 93%, ppv 97%) and a low level of agreement for smoking (sens 18%, spec 99%, ppv 89%), obesity (sens 22%, spec 99%, ppv 99%) and dyslipidemia (sens 40%, spec 60%, ppv 70%). Depending on the investigated cardiovascular risk factor, medication, documented additional cardiovascular co-morbidities, age, sex and clinical severity were associated with the ICD-coded cardiovascular risk factor. The quality of ICD-coding in ambulatory care is highly variable for different cardiovascular risk factors and outcomes. Diagnoses were generally undercoded, but those relevant for billing were coded more frequently. Our results can be used to quantify errors in population-based estimates of prevalence based on claims data for the investigated cardiovascular risk factors. © Georg Thieme Verlag KG Stuttgart · New York.

  19. Using Hashimoto thyroiditis as gold standard to determine the upper limit value of thyroid stimulating hormone in a Chinese cohort.

    PubMed

    Li, Yu; Chen, Dong-Ning; Cui, Jing; Xin, Zhong; Yang, Guang-Ran; Niu, Ming-Jia; Yang, Jin-Kui

    2016-11-06

    Subclinical hypothyroidism, commonly caused by Hashimoto thyroiditis (HT), is a risk factor for cardiovascular diseases. This disorder is defined as merely having elevated serum thyroid stimulating hormone (TSH) levels. However, the upper limit of reference range for TSH is debated recently. This study was to determine the cutoff value for the upper normal limit of TSH in a cohort using the prevalence of Hashimoto thyroiditis as "gold" calibration standard. The research population was medical staff of 2856 individuals who took part in health examination annually. Serum free triiodothyronine (FT3), free thyroxine (FT4), TSH, thyroid peroxidase antibody (TPAb), thyroglobulin antibody (TGAb) and other biochemistry parameters were tested. Meanwhile, thyroid ultrasound examination was performed. The diagnosis of HT was based on presence of thyroid antibodies (TPAb and TGAb) and abnormalities of thyroid ultrasound examination. We used two different methods to estimate the cutoff point of TSH based on the prevalence of HT. Joinpoint regression showed the prevalence of HT increased significantly at the ninth decile of TSH value corresponding to 2.9 mU/L. ROC curve showed a TSH cutoff value of 2.6 mU/L with the maximized sensitivity and specificity in identifying HT. Using the newly defined cutoff value of TSH can detect patients with hyperlipidemia more efficiently, which may indicate our approach to define the upper limit of TSH can make more sense from the clinical point of view. A significant increase in the prevalence of HT occurred among individuals with a TSH of 2.6-2.9 mU/L made it possible to determine the cutoff value of normal upper limit of TSH.

  20. Risk based meat hygiene--examples on food chain information and visual meat inspection.

    PubMed

    Ellerbroek, Lüppo

    2007-08-01

    The Regulation (EC) No. 854/2004 refers in particularly to a broad spectrum of official supervision of products of animal origin. The supervision should be based on the most current relevant information which is available. The proposal presented includes forms for implementation of Food Chain Information (FCI) as laid down in the Regulation (EC) No. 853/2004 as well as suggestions for the implementation of the visual inspection and criteria for a practical approach to assist the competent authority and the business operator. These suggestions are summarised in two forms including the FCI and practical information from the farm of origin as well as from the slaughterhouse needed for the competent authority to permit the visual meat inspection of fattening pigs. The requested information from the farm level include i.e. an animal loss rate during the fattening period and diagnostic findings of carcasses and respectively on organs of the animals during meat inspection procedure. The evaluation of findings in liver and pleura at the slaughterhouse level indicate a correlation to the general health status of the fattening conditions at farm level. The criteria developed are in principle suited for a "gold standard" of the health status of fattening pigs and the criteria may serve as practical implementation of the term Good Farming Practice in relation to consumer protection. Only for fattening pigs deriving from farms fulfilling this "gold standard" the visual meat inspection shall be permitted. It is proposed to integrate the two forms for FCI and additional information for authorisation of visual meat inspection for fattening pigs in the working document of the DG SANCO titled "Commission regulation of laying down specific rules on official controls for the inspection of meat" (SANCO/2696/2006).

  1. Frequency, diagnostic performance of coproantigen detection and genotyping of the Giardia among patients referred to a multi-level teaching hospital in northern India.

    PubMed

    Ghoshal, Ujjala; Shukla, Ratnakar; Pant, Priyannk; Ghoshal, Uday C

    Giardiasis, a common gastrointestinal parasitic infection in tropics, is diagnosed on stool microscopy (gold standard); however, its sensitivity is low due to intermittent fecal shedding. Coproantigen detection (ELISA) is useful but requires further evaluation. We aimed to study: (a) detection of Giardia by stool microscopy and/or coproantigen, (b) diagnostic performance of fecal antigen detection and microscopy, and c) genotypic characterization of G. lamblia using PCR specific for triose phosphate isomerase (tpi) gene. Stool samples from 2992 patients were examined by microscopy from March 2013 to March 2015 in a multi level teaching hospital in northern India. Giardia coproantigen detection was performed by ELISA in a subset of patients. Genetic characterization of G. lamblia was performed by PCR targeting tpi gene in a subset of microscopy positive stool samples. Of 2992 patients, 132 (4.4%) had Giardia by microscopy (cyst/trophozoite) and/or ELISA. ELISA was performed in 264 patients; of them, 127 were positive by microscopy. Sensitivity, specificity, positive and negative predictive values of ELISA were 91, 91, 94, and 91%, respectively, using microscopy as a gold standard. PCR was performed in 116 randomly selected samples having Giardia using tpi gene. Assemblages A and B were found among 44 (38%) and 72 (62%) patients, respectively. Assemblage B was more often associated with malnutrition and loss of appetite than A (48/72 [67%] vs. 21/44 [48%], P = 0.044 and 17/72 [24%] vs. 14/44 [32%], P = 0.019). We conclude that 4.4% of studied population had giardiasis. Fecal antigen is a useful method for diagnosis and assemblage B is the most common genotype.

  2. Correlations between contouring similarity metrics and simulated treatment outcome for prostate radiotherapy

    NASA Astrophysics Data System (ADS)

    Roach, D.; Jameson, M. G.; Dowling, J. A.; Ebert, M. A.; Greer, P. B.; Kennedy, A. M.; Watt, S.; Holloway, L. C.

    2018-02-01

    Many similarity metrics exist for inter-observer contouring variation studies, however no correlation between metric choice and prostate cancer radiotherapy dosimetry has been explored. These correlations were investigated in this study. Two separate trials were undertaken, the first a thirty-five patient cohort with three observers, the second a five patient dataset with ten observers. Clinical and planning target volumes (CTV and PTV), rectum, and bladder were independently contoured by all observers in each trial. Structures were contoured on T2-weighted MRI and transferred onto CT following rigid registration for treatment planning in the first trial. Structures were contoured directly on CT in the second trial. STAPLE and majority voting volumes were generated as reference gold standard volumes for each structure for the two trials respectively. VMAT treatment plans (78 Gy to PTV) were simulated for observer and gold standard volumes, and dosimetry assessed using multiple radiobiological metrics. Correlations between contouring similarity metrics and dosimetry were calculated using Spearman’s rank correlation coefficient. No correlations were observed between contouring similarity metrics and dosimetry for CTV within either trial. Volume similarity correlated most strongly with radiobiological metrics for PTV in both trials, including TCPPoisson (ρ  =  0.57, 0.65), TCPLogit (ρ  =  0.39, 0.62), and EUD (ρ  =  0.43, 0.61) for each respective trial. Rectum and bladder metric correlations displayed no consistency for the two trials. PTV volume similarity was found to significantly correlate with rectum normal tissue complication probability (ρ  =  0.33, 0.48). Minimal to no correlations with dosimetry were observed for overlap or boundary contouring metrics. Future inter-observer contouring variation studies for prostate cancer should incorporate volume similarity to provide additional insights into dosimetry during analysis.

  3. Validation of Contact-Free Sleep Monitoring Device with Comparison to Polysomnography.

    PubMed

    Tal, Asher; Shinar, Zvika; Shaki, David; Codish, Shlomi; Goldbart, Aviv

    2017-03-15

    To validate a contact-free system designed to achieve maximal comfort during long-term sleep monitoring, together with high monitoring accuracy. We used a contact-free monitoring system (EarlySense, Ltd., Israel), comprising an under-the-mattress piezoelectric sensor and a smartphone application, to collect vital signs and analyze sleep. Heart rate (HR), respiratory rate (RR), body movement, and calculated sleep-related parameters from the EarlySense (ES) sensor were compared to data simultaneously generated by the gold standard, polysomnography (PSG). Subjects in the sleep laboratory underwent overnight technician-attended full PSG, whereas subjects at home were recorded for 1 to 3 nights with portable partial PSG devices. Data were compared epoch by epoch. A total of 63 subjects (85 nights) were recorded under a variety of sleep conditions. Compared to PSG, the contact-free system showed similar values for average total sleep time (TST), % wake, % rapid eye movement, and % non-rapid eye movement sleep, with 96.1% and 93.3% accuracy of continuous measurement of HR and RR, respectively. We found a linear correlation between TST measured by the sensor and TST determined by PSG, with a coefficient of 0.98 (R = 0.87). Epoch-by-epoch comparison with PSG in the sleep laboratory setting revealed that the system showed sleep detection sensitivity, specificity, and accuracy of 92.5%, 80.4%, and 90.5%, respectively. TST estimates with the contact-free sleep monitoring system were closely correlated with the gold-standard reference. This system shows good sleep staging capability with improved performance over accelerometer-based apps, and collects additional physiological information on heart rate and respiratory rate. © 2017 American Academy of Sleep Medicine

  4. Validation of different techniques for the diagnosis of ventilator-associated pneumonia. Comparison with immediate postmortem pulmonary biopsy.

    PubMed

    Torres, A; el-Ebiary, M; Padró, L; Gonzalez, J; de la Bellacasa, J P; Ramirez, J; Xaubet, A; Ferrer, M; Rodriguez-Roisin, R

    1994-02-01

    To assess the accuracy of clinical parameters for the diagnosis of ventilator-associated (VA) pneumonia, as well as the diagnostic value of several invasive techniques, such as protected specimen brush (PSB), bronchoalveolar lavage (BAL), fiberoptic bronchial aspirates (FBAS), and percutaneous lung needle aspiration (PLNA), we compared the results of these techniques with the histopathology of immediate postmortem pulmonary biopsies, considered the "gold standard" reference test. We studied 30 mechanically ventilated patients (age 52 +/- 21 yr; mechanical ventilation period 9 +/- 7 days) who died in an intensive care unit. All patients received prior antibiotic treatment. The following procedures were performed immediately after death: bilateral PSB, BAL, FBAS, and PLNA, as well as bilateral minithoracotomies to obtain pulmonary biopsies as close as possible to the area sampled with the other techniques. According to the histopathology 18 patients had pneumonia and 12 did not. The presence of fever (sensitivity 55%, specificity 58%), purulent secretions (sensitivity 83%, specificity 33%), and chest radiograph infiltrates (sensitivity 78%, specificity 42%) could not differentiate in all instances presence from absence of pneumonia. Quantitative bacterial cultures of lung biopsies using 10(3) cfu/g as a cutoff point had low sensitivity (40%) and low specificity (45%) and could not differentiate the histologic absence or presence of pneumonia. Considering the histopathology of pulmonary biopsies as a gold standard, we found the following sensitivities for PSB, BAL, FBAS, and PLNA: 36, 50, 44, and 25%. The specificities were 50, 45, 48, and 79%, respectively. The sensitivities and specificities of different invasive techniques are much lower than those reported in clinical studies.(ABSTRACT TRUNCATED AT 250 WORDS)

  5. Sensitivity and specificity of the amer dizziness diagnostic scale (adds) for patients with vestibular disorders.

    PubMed

    Al Saif, Amer; Alsenany, Samira

    2015-01-01

    [Purpose] To investigate the sensitivity and specificity of a newly developed diagnostic tool, the Amer Dizziness Diagnostic Scale (ADDS), to evaluate and differentially diagnose vestibular disorder and to identify the strengths and weaknesses of the scale and its usefulness in clinical practice. [Subjects and Methods] Two hundred subjects of both genders (72 males, 128 females) aged between 18 to 60 (49.5±7.8) who had a history of vertigo and/or dizziness symptoms for this previous two weeks or less were recruited for the study. All subjects were referred by otolaryngologists, neurologists or family physicians in and around Jeddah, Kingdom of Saudi Arabia. On the first clinic visit, all the patients were evaluated once using the ADDS, following which they underwent routine testing of clinical signs and symptoms, audiometry, and a neurological examination, coupled with tests of Vestibulo-Ocular Reflex function, which often serves as the "gold standard" for determining the probability of a vestibular deficit. [Results] The results show that the ADDS strongly correlated with "true-positive" and "true-negative" responses for determining the probability of a vestibular disorder (r =0.95). A stepwise linear regression was conducted and the results indicate that the ADDS was a significant predictor of "true-positive" and "true-negative" responses in vestibular disorders (R(2) =0.90). Approximately 90% of the variability in the vestibular gold standard test was explained by its relationship to the ADDS. Moreover, the ADDS was found to have a sensitivity of 96% and a specificity of 96%. [Conclusion] This study showed that the Amer Dizziness Diagnostic Scale has high sensitivity and specificity and that it can be used as a method of differential diagnosis for patients with vestibular disorders.

  6. Magnetic resonance fingerprinting using echo-planar imaging: Joint quantification of T1 and T2∗ relaxation times.

    PubMed

    Rieger, Benedikt; Zimmer, Fabian; Zapp, Jascha; Weingärtner, Sebastian; Schad, Lothar R

    2017-11-01

    To develop an implementation of the magnetic resonance fingerprinting (MRF) paradigm for quantitative imaging using echo-planar imaging (EPI) for simultaneous assessment of T 1 and T2∗. The proposed MRF method (MRF-EPI) is based on the acquisition of 160 gradient-spoiled EPI images with rapid, parallel-imaging accelerated, Cartesian readout and a measurement time of 10 s per slice. Contrast variation is induced using an initial inversion pulse, and varying the flip angles, echo times, and repetition times throughout the sequence. Joint quantification of T 1 and T2∗ is performed using dictionary matching with integrated B1+ correction. The quantification accuracy of the method was validated in phantom scans and in vivo in 6 healthy subjects. Joint T 1 and T2∗ parameter maps acquired with MRF-EPI in phantoms are in good agreement with reference measurements, showing deviations under 5% and 4% for T 1 and T2∗, respectively. In vivo baseline images were visually free of artifacts. In vivo relaxation times are in good agreement with gold-standard techniques (deviation T 1 : 4 ± 2%, T2∗: 4 ± 5%). The visual quality was comparable to the in vivo gold standard, despite substantially shortened scan times. The proposed MRF-EPI method provides fast and accurate T 1 and T2∗ quantification. This approach offers a rapid supplement to the non-Cartesian MRF portfolio, with potentially increased usability and robustness. Magn Reson Med 78:1724-1733, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  7. 3D multiplexed immunoplasmonics microscopy

    NASA Astrophysics Data System (ADS)

    Bergeron, Éric; Patskovsky, Sergiy; Rioux, David; Meunier, Michel

    2016-07-01

    Selective labelling, identification and spatial distribution of cell surface biomarkers can provide important clinical information, such as distinction between healthy and diseased cells, evolution of a disease and selection of the optimal patient-specific treatment. Immunofluorescence is the gold standard for efficient detection of biomarkers expressed by cells. However, antibodies (Abs) conjugated to fluorescent dyes remain limited by their photobleaching, high sensitivity to the environment, low light intensity, and wide absorption and emission spectra. Immunoplasmonics is a novel microscopy method based on the visualization of Abs-functionalized plasmonic nanoparticles (fNPs) targeting cell surface biomarkers. Tunable fNPs should provide higher multiplexing capacity than immunofluorescence since NPs are photostable over time, strongly scatter light at their plasmon peak wavelengths and can be easily functionalized. In this article, we experimentally demonstrate accurate multiplexed detection based on the immunoplasmonics approach. First, we achieve the selective labelling of three targeted cell surface biomarkers (cluster of differentiation 44 (CD44), epidermal growth factor receptor (EGFR) and voltage-gated K+ channel subunit KV1.1) on human cancer CD44+ EGFR+ KV1.1+ MDA-MB-231 cells and reference CD44- EGFR- KV1.1+ 661W cells. The labelling efficiency with three stable specific immunoplasmonics labels (functionalized silver nanospheres (CD44-AgNSs), gold (Au) NSs (EGFR-AuNSs) and Au nanorods (KV1.1-AuNRs)) detected by reflected light microscopy (RLM) is similar to the one with immunofluorescence. Second, we introduce an improved method for 3D localization and spectral identification of fNPs based on fast z-scanning by RLM with three spectral filters corresponding to the plasmon peak wavelengths of the immunoplasmonics labels in the cellular environment (500 nm for 80 nm AgNSs, 580 nm for 100 nm AuNSs and 700 nm for 40 nm × 92 nm AuNRs). Third, the developed technology is simple and compatible with standard epi-fluorescence microscopes used in biological and clinical laboratories. Thus, 3D multiplexed immunoplasmonics microscopy is ready for clinical applications as a cost-efficient alternative to immunofluorescence.Selective labelling, identification and spatial distribution of cell surface biomarkers can provide important clinical information, such as distinction between healthy and diseased cells, evolution of a disease and selection of the optimal patient-specific treatment. Immunofluorescence is the gold standard for efficient detection of biomarkers expressed by cells. However, antibodies (Abs) conjugated to fluorescent dyes remain limited by their photobleaching, high sensitivity to the environment, low light intensity, and wide absorption and emission spectra. Immunoplasmonics is a novel microscopy method based on the visualization of Abs-functionalized plasmonic nanoparticles (fNPs) targeting cell surface biomarkers. Tunable fNPs should provide higher multiplexing capacity than immunofluorescence since NPs are photostable over time, strongly scatter light at their plasmon peak wavelengths and can be easily functionalized. In this article, we experimentally demonstrate accurate multiplexed detection based on the immunoplasmonics approach. First, we achieve the selective labelling of three targeted cell surface biomarkers (cluster of differentiation 44 (CD44), epidermal growth factor receptor (EGFR) and voltage-gated K+ channel subunit KV1.1) on human cancer CD44+ EGFR+ KV1.1+ MDA-MB-231 cells and reference CD44- EGFR- KV1.1+ 661W cells. The labelling efficiency with three stable specific immunoplasmonics labels (functionalized silver nanospheres (CD44-AgNSs), gold (Au) NSs (EGFR-AuNSs) and Au nanorods (KV1.1-AuNRs)) detected by reflected light microscopy (RLM) is similar to the one with immunofluorescence. Second, we introduce an improved method for 3D localization and spectral identification of fNPs based on fast z-scanning by RLM with three spectral filters corresponding to the plasmon peak wavelengths of the immunoplasmonics labels in the cellular environment (500 nm for 80 nm AgNSs, 580 nm for 100 nm AuNSs and 700 nm for 40 nm × 92 nm AuNRs). Third, the developed technology is simple and compatible with standard epi-fluorescence microscopes used in biological and clinical laboratories. Thus, 3D multiplexed immunoplasmonics microscopy is ready for clinical applications as a cost-efficient alternative to immunofluorescence. Electronic supplementary information (ESI) available: Characterization of functionalized nanoparticles by UV-visible-NIR spectroscopy, standard dark field microscopy and reflected light microscopy. Immunofluorescence of cells. See DOI: 10.1039/c6nr01257d

  8. Surface plasmon resonance sensor based on photonic crystal fiber filled with gold-silica-gold multilayer nanoshells

    NASA Astrophysics Data System (ADS)

    Liu, Baolin; Lu, Ying; Yang, Xianchao; Yao, Jianquan

    2017-12-01

    We present a surface plasmon resonance sensor based on photonic crystal fiber filled with gold-silica-gold (GSG) multilayer nanoshells for measurement of the refractive index of liquid analyte. The GSG multilayer nanoshells, composed of a silica-coated gold nanosphere surrounded by a gold shell layer, are designed to be the functional material of the sensor because of their attractive optical properties. Two resonant peaks are obtained due to the hybridization of nanosphere plasmon modes and nanoshell plasmon modes. It is demonstrated that the resonant wavelength of the two peaks can be precisely tuned in 560-716 nm and 849-2485 nm, respectively, by varying the structural parameters of the GSG multilayer nanoshells in a compact, sub-200 nm size range. The excellent spectral tunability makes the sensor attractive in a wide range of applications, especially in biosensing in near-infrared region. Furthermore, the influences of the parameters on the performance of the sensor are systematically simulated and discussed. It is observed that the spectral sensitivities of 1894.3 nm/RIU and 3011.4 nm/RIU can be achieved respectively by the two resonant peaks in the sensing range of 1.33-1.38. The existence of two loss peaks also provides the possibility to realize self-reference in the sensing process.

  9. Federal Criteria for Studies Grow

    ERIC Educational Resources Information Center

    Sparks, Sarah D.

    2010-01-01

    The author reports on the U.S. Department of Education's "What Works Clearinghouse" that goes beyond "gold standard" research and sets standards for accepting other types of studies. As part of the Institute of Education Sciences' push to make research more relevant to educators, the federal clearinghouse has devised standards by which it can…

  10. Value of the 13C-urea breath test for detection of gastric Helicobacter spp. infection in dogs undergoing endoscopic examination.

    PubMed

    Kubota, Sanae; Ohno, Koichi; Tsukamoto, Atsushi; Maeda, Shingo; Murata, Yosuke; Nakashima, Ko; Fukushima, Kenjiro; Uchida, Kazuyuki; Fujino, Yasuhito; Tsujimoto, Hajime

    2013-01-01

    Urea breath test (UBT) using an infrared spectral analyzer is widely used for non-invasive and rapid detection of gastric Helicobacter spp. in human, but not veterinary medicine. The main purposes of this study were to determine the reference range of the UBT in dogs and to evaluate its clinical usefulness. To address the first aim, 6 healthy laboratory beagles were subjected to UBT and upper gastrointestinal endoscopy. Gastric endoscopic biopsy samples from the antrum, corpus and fundus were examined for Helicobacter spp. by polymerase chain reaction (PCR) testing, rapid urease test (RUT), histology and cytology. Amoxicillin, metronidazole and omeprazole were given to infected dogs for 14 days, and dogs that became Helicobacter-negative were used to determine the reference range for UBT. To address the second aim, 32 canine patients underwent UBT before upper gastrointestinal endoscopy, and the sensitivity and specificity of UBT were calculated based on our newly determined reference range using PCR as the gold standard for detection of Helicobacter spp. Initially, all 6 laboratory beagles were infected in all gastric regions and became uninfected after eradication. The mean ± 2 SD UBT value after eradication was 0.6 ± 1.8‰, and the reference range for UBT was determined to be less than 2.5‰. UBT was completed successfully in 27 patients. Using our reference range, UBT displayed 89% (16/18) sensitivity and 89% (8/9) specificity, indicating that UBT was quite useful for the detection of gastric Helicobacter spp. infection in dogs.

  11. Publications - GMC 320 | Alaska Division of Geological & Geophysical

    Science.gov Websites

    DGGS GMC 320 Publication Details Title: Summary results of short-wave infrared spectroscopy of the gold Reference PetraScience Consultants Inc., 2005, Summary results of short-wave infrared spectroscopy of the

  12. Dr. R. Adams Cowley Congressional Gold Medal Act

    THOMAS, 113th Congress

    Sen. Mikulski, Barbara A. [D-MD

    2013-07-23

    Senate - 07/23/2013 Read twice and referred to the Committee on Banking, Housing, and Urban Affairs. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:

  13. Achievements of the GI Bill Gold Medal Act

    THOMAS, 111th Congress

    Sen. Brownback, Sam [R-KS

    2010-04-29

    Senate - 04/29/2010 Read twice and referred to the Committee on Banking, Housing, and Urban Affairs. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:

  14. Office of Strategic Services Congressional Gold Medal Act

    THOMAS, 113th Congress

    Sen. Kirk, Mark Steven [R-IL

    2013-11-13

    Senate - 11/13/2013 Read twice and referred to the Committee on Banking, Housing, and Urban Affairs. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:

  15. Blue Star/Gold Star Flag Act of 2011

    THOMAS, 112th Congress

    Sen. Webb, Jim [D-VA

    2011-02-17

    Senate - 02/17/2011 Read twice and referred to the Committee on Banking, Housing, and Urban Affairs. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:

  16. Intrathoracic airway measurement: ex-vivo validation

    NASA Astrophysics Data System (ADS)

    Reinhardt, Joseph M.; Raab, Stephen A.; D'Souza, Neil D.; Hoffman, Eric A.

    1997-05-01

    High-resolution x-ray CT (HRCT) provides detailed images of the lungs and bronchial tree. HRCT-based imaging and quantitation of peripheral bronchial airway geometry provides a valuable tool for assessing regional airway physiology. Such measurements have been sued to address physiological questions related to the mechanics of airway collapse in sleep apnea, the measurement of airway response to broncho-constriction agents, and to evaluate and track the progression of disease affecting the airways, such as asthma and cystic fibrosis. Significant attention has been paid to the measurements of extra- and intra-thoracic airways in 2D sections from volumetric x-ray CT. A variety of manual and semi-automatic techniques have been proposed for airway geometry measurement, including the use of standardized display window and level settings for caliper measurements, methods based on manual or semi-automatic border tracing, and more objective, quantitative approaches such as the use of the 'half-max' criteria. A recently proposed measurements technique uses a model-based deconvolution to estimate the location of the inner and outer airway walls. Validation using a plexiglass phantom indicates that the model-based method is more accurate than the half-max approach for thin-walled structures. In vivo validation of these airway measurement techniques is difficult because of the problems in identifying a reliable measurement 'gold standard.' In this paper we report on ex vivo validation of the half-max and model-based methods using an excised pig lung. The lung is sliced into thin sections of tissue and scanned using an electron beam CT scanner. Airways of interest are measured from the CT images, and also measured with using a microscope and micrometer to obtain a measurement gold standard. The result show no significant difference between the model-based measurements and the gold standard; while the half-max estimates exhibited a measurement bias and were significantly different than the gold standard.

  17. Measuring total mercury due to small-scale gold mining activities to determine community vulnerability in Cihonje, Central Java, Indonesia.

    PubMed

    Sari, Mega M; Inoue, Takanobu; Matsumoto, Yoshitaka; Yokota, Kuriko

    2016-01-01

    This research is comparative study of gold mining and non-gold mining areas, using four community vulnerability indicators. Vulnerability indicators are exposure degree, contamination rate, chronic, and acute toxicity. Each indicator used different samples, such as wastewater from gold mining process, river water from Tajum river, human hair samples, and health questionnaire. This research used cold vapor atomic absorption spectrometry to determine total mercury concentration. The result showed that concentration of total mercury was 2,420 times than the maximum content of mercury permitted in wastewater based on the Indonesian regulation. Moreover, the mercury concentration in river water reached 685 ng/l, exceeding the quality threshold standards of the World Health Organization (WHO). The mercury concentration in hair samples obtained from the people living in the research location was considered to identify the health quality level of the people or as a chronic toxicity indicator. The highest mercury concentration--i.e. 17 ng/mg, was found in the gold mining respondents. Therefore, based on the total mercury concentration in the four indicators, the community in the gold mining area were more vulnerable to mercury than communities in non-gold mining areas. It was concluded that the community in gold mining area was more vulnerable to mercury contamination than the community in non-gold mining area.

  18. Should centralized histopathological review in penile cancer be the global standard?

    PubMed

    Tang, Vincent; Clarke, Laurence; Gall, Zara; Shanks, Jonathan H; Nonaka, Daisuke; Parr, Nigel J; Elliott, P Anthony; Clarke, Noel W; Ramani, Vijay; Lau, Maurice W; Sangar, Vijay K

    2014-09-01

    To assess the role of centralized pathological review in penile cancer management. Newly diagnosed squamous cell carcinomas (SCC) of the penis, including squamous cell carcinoma in situ (CIS), from biopsy specimens were referred from 15 centres to the regional supra-network multidisciplinary team (Sn-MDT) between 1 January 2008 and 30 March 2011. Biopsy histology reports and slides from the respective referring hospitals were reviewed by the Sn-MDT pathologists. The biopsy specimens' histological type, grade and stage reported by the Sn-MDT pathologist were compared with those given in the referring hospital pathology report, as well as with definitive surgery histology. Any changes in histological diagnosis were sub-divided into critical changes (i.e. those that could alter management) and non-critical changes (i.e. those that would not affect management). A total of 155 cases of squamous cell carcinoma or CIS of the penis were referred from 15 different centres in North-West England. After review by the Sn-MDT, the histological diagnosis was changed in 31% of cases and this difference was statistically significant. A total of 60.4% of the changes were deemed to be critical changes that resulted in a significant change in management. When comparing the biopsy histology reported by the Sn-MDT with the final histology from the definitive surgical specimens, a good correlation was generally found. In the present study a significant proportion of penile cancer histology reports were revised after review by the Sn-MDT. Many of these changes altered patient management. The present study shows that accurate pathological diagnosis plays a crucial role in determining the correct treatment and maximizing the potential for good clinical outcomes in penile cancer. In the case of histopathology, centralization has increased exposure to penile cancer and thereby increased diagnostic accuracy, and should therefore be considered the 'gold standard'. © 2013 The Authors. BJU International © 2013 BJU International.

  19. Electrodeposition of gold particles on aluminum substrates containing copper.

    PubMed

    Olson, Tim S; Atanassov, Plamen; Brevnov, Dmitri A

    2005-01-27

    Electrodeposition of adhesive metal films on aluminum is traditionally preceded by the zincate process, which activates the aluminum surface. This paper presents an alternative approach for activation of aluminum by using films containing 99.5% aluminum and 0.5% copper. Aluminum/copper films are made amenable for subsequent electrodeposition by anodization followed by chemical etching of aluminum oxide. The electrodeposition of gold is monitored with electrochemical impedance spectroscopy (EIS). Analysis of EIS data suggests that electrodeposition of gold increases the interfacial capacitance from values typical for electrodes with thin oxide layers to values typical for metal electrodes. Scanning electron microscopy examination of aluminum/copper films following gold electrodeposition shows the presence of gold particles with densities of 10(5)-10(7) particles cm(-2). The relative standard deviation of mean particle diameters is approximately 25%. Evaluation of the micrographs suggests that the electrodeposition occurs by instantaneous nucleation followed by growth of three-dimensional semispherical particles. The gold particles, which are electrically connected to the conductive aluminum/copper film, support a reversible faradaic process for a soluble redox couple. The deposited gold particles are suitable for subsequent metallization of aluminum and fabrication of particle-type films with interesting catalytic, electrical, and optical properties.

  20. Diameter-dependent optical constants of gold mesoparticles electrodeposited on aluminum films containing copper.

    PubMed

    Brevnov, Dmitri A; Bungay, Corey

    2005-08-04

    Electrodeposition of gold mesoparticles on anodized and chemically etched aluminum/copper films deposited on silicon wafers proceeds by instantaneous nucleation and with no diffusion limitations. Both of these phenomena favor the formation of relatively monodispersed gold particles. Under the reported electrodeposition conditions, the relative standard deviation of the particle diameter is 25%. The particle coverage is 7 x 10(8) particles cm(-2). The mean particle diameter varies as a function of electrodeposition time in the range of 40-80 nm. Optical constants of gold mesoparticles are resolved by spectroscopic ellipsometry. A two-layer optical model is constructed to determine both extinction coefficients and refractive indexes of gold mesoparticles as a function of the mean particle diameter. The absorption peak, associated with surface plasmons, is modeled with two Lorentz oscillators. Absorption peak maximums shift from 610 to 675 nm as the mean particle diameter increases from 42 to 74 nm. Electrodeposition of gold particles on technologically relevant substrates, such as aluminum/copper films, is expected to increase the utility of gold particles and facilitate their incorporation in nanostructured materials and a variety of electronic and optical devices.

  1. The challenge of determining handedness in electron tomography and the use of DNA origami gold nanoparticle helices as molecular standards

    PubMed Central

    Briegel, Ariane; Pilhofer, Martin; Mastronarde, David N.; Jensen, Grant J.

    2013-01-01

    The apparent handedness of an EM-tomography reconstruction depends on a number of conventions and can be confused in many ways. As the number of different hardware and software combinations being used for electron tomography continue to climb, and the reconstructions being produced reach higher and higher resolutions, the need to verify the hand of the results has increased. Here we enumerate various steps in a typical tomography experiment that affect handedness and show that DNA origami gold nanoparticle helices can be used as convenient and fail-safe handedness standards. PMID:23639902

  2. Oncology Gold Standard™ practical consensus recommendations 2016 for treatment of advanced clear cell renal cell carcinoma.

    PubMed

    Batra, U; Parikh, P M; Prabhash, K; Tongaonkar, H B; Chibber, P; Dabkara, D; Deshmukh, C; Ghadyalpatil, N; Hingmire, S; Joshi, A; Raghunath, S K; Rajappa, S; Rajendranath, R; Rawal, S K; Singh, Manisha; Singh, R; Somashekhar, S P; Sood, R

    2016-01-01

    The Oncology Gold Standard (OGS) Expert Group on renal cell carcinoma (RCC) developed the consensus statement to provide community oncologists practical guidelines on the management of advanced clear cell (cc) RCC using published evidence, practical experience of experts in real life management, and results of a nationwide survey involving 144 health-care professionals. Six broad question categories containing 33 unique questions cover major situations in the routine management of RCC. This document serves as a ready guide for the standard of care to optimize outcome. The table of "Take Home Messages" at the end is a convenient tool for busy practitioners.

  3. NCI Updates Tobacco Policies Following Re-accreditation | Poster

    Cancer.gov

    This year, NCI was re-accredited as one of nearly 200 CEO Cancer Gold Standard employers across the United States. According to its website, “the CEO Cancer Gold Standard provides a framework for employers to have a healthier workplace by focusing on cancer risk reduction, early detection, and access to clinical trials and high-quality care.” As part of this re-accreditation, NCI has updated its Tobacco-Free Policy. Part of this policy includes posting signs around campus reminding visitors and staff that NCI’s campus is tobacco-free. Therefore, the use of all tobacco products is prohibited. This includes cigarettes, cigars, pipes, e-cigarettes, and smokeless tobacco.

  4. Probabilistic brain tissue segmentation in neonatal magnetic resonance imaging.

    PubMed

    Anbeek, Petronella; Vincken, Koen L; Groenendaal, Floris; Koeman, Annemieke; van Osch, Matthias J P; van der Grond, Jeroen

    2008-02-01

    A fully automated method has been developed for segmentation of four different structures in the neonatal brain: white matter (WM), central gray matter (CEGM), cortical gray matter (COGM), and cerebrospinal fluid (CSF). The segmentation algorithm is based on information from T2-weighted (T2-w) and inversion recovery (IR) scans. The method uses a K nearest neighbor (KNN) classification technique with features derived from spatial information and voxel intensities. Probabilistic segmentations of each tissue type were generated. By applying thresholds on these probability maps, binary segmentations were obtained. These final segmentations were evaluated by comparison with a gold standard. The sensitivity, specificity, and Dice similarity index (SI) were calculated for quantitative validation of the results. High sensitivity and specificity with respect to the gold standard were reached: sensitivity >0.82 and specificity >0.9 for all tissue types. Tissue volumes were calculated from the binary and probabilistic segmentations. The probabilistic segmentation volumes of all tissue types accurately estimated the gold standard volumes. The KNN approach offers valuable ways for neonatal brain segmentation. The probabilistic outcomes provide a useful tool for accurate volume measurements. The described method is based on routine diagnostic magnetic resonance imaging (MRI) and is suitable for large population studies.

  5. Acquisition and evaluation of verb subcategorization resources for biomedicine.

    PubMed

    Rimell, Laura; Lippincott, Thomas; Verspoor, Karin; Johnson, Helen L; Korhonen, Anna

    2013-04-01

    Biomedical natural language processing (NLP) applications that have access to detailed resources about the linguistic characteristics of biomedical language demonstrate improved performance on tasks such as relation extraction and syntactic or semantic parsing. Such applications are important for transforming the growing unstructured information buried in the biomedical literature into structured, actionable information. In this paper, we address the creation of linguistic resources that capture how individual biomedical verbs behave. We specifically consider verb subcategorization, or the tendency of verbs to "select" co-occurrence with particular phrase types, which influences the interpretation of verbs and identification of verbal arguments in context. There are currently a limited number of biomedical resources containing information about subcategorization frames (SCFs), and these are the result of either labor-intensive manual collation, or automatic methods that use tools adapted to a single biomedical subdomain. Either method may result in resources that lack coverage. Moreover, the quality of existing verb SCF resources for biomedicine is unknown, due to a lack of available gold standards for evaluation. This paper presents three new resources related to verb subcategorization frames in biomedicine, and four experiments making use of the new resources. We present the first biomedical SCF gold standards, capturing two different but widely-used definitions of subcategorization, and a new SCF lexicon, BioCat, covering a large number of biomedical sub-domains. We evaluate the SCF acquisition methodologies for BioCat with respect to the gold standards, and compare the results with the accuracy of the only previously existing automatically-acquired SCF lexicon for biomedicine, the BioLexicon. Our results show that the BioLexicon has greater precision while BioCat has better coverage of SCFs. Finally, we explore the definition of subcategorization using these resources and its implications for biomedical NLP. All resources are made publicly available. The SCF resources we have evaluated still show considerably lower accuracy than that reported with general English lexicons, demonstrating the need for domain- and subdomain-specific SCF acquisition tools for biomedicine. Our new gold standards reveal major differences when annotators use the different definitions. Moreover, evaluation of BioCat yields major differences in accuracy depending on the gold standard, demonstrating that the definition of subcategorization adopted will have a direct impact on perceived system accuracy for specific tasks. Copyright © 2013 Elsevier Inc. All rights reserved.

  6. Breast density quantification with cone-beam CT: A post-mortem study

    PubMed Central

    Johnson, Travis; Ding, Huanjun; Le, Huy Q.; Ducote, Justin L.; Molloi, Sabee

    2014-01-01

    Forty post-mortem breasts were imaged with a flat-panel based cone-beam x-ray CT system at 50 kVp. The feasibility of breast density quantification has been investigated using standard histogram thresholding and an automatic segmentation method based on the fuzzy c-means algorithm (FCM). The breasts were chemically decomposed into water, lipid, and protein immediately after image acquisition was completed. The percent fibroglandular volume (%FGV) from chemical analysis was used as the gold standard for breast density comparison. Both image-based segmentation techniques showed good precision in breast density quantification with high linear coefficients between the right and left breast of each pair. When comparing with the gold standard using %FGV from chemical analysis, Pearson’s r-values were estimated to be 0.983 and 0.968 for the FCM clustering and the histogram thresholding techniques, respectively. The standard error of the estimate (SEE) was also reduced from 3.92% to 2.45% by applying the automatic clustering technique. The results of the postmortem study suggested that breast tissue can be characterized in terms of water, lipid and protein contents with high accuracy by using chemical analysis, which offers a gold standard for breast density studies comparing different techniques. In the investigated image segmentation techniques, the FCM algorithm had high precision and accuracy in breast density quantification. In comparison to conventional histogram thresholding, it was more efficient and reduced inter-observer variation. PMID:24254317

  7. Improving practice in community-based settings: a randomized trial of supervision – study protocol

    PubMed Central

    2013-01-01

    Background Evidence-based treatments for child mental health problems are not consistently available in public mental health settings. Expanding availability requires workforce training. However, research has demonstrated that training alone is not sufficient for changing provider behavior, suggesting that ongoing intervention-specific supervision or consultation is required. Supervision is notably under-investigated, particularly as provided in public mental health. The degree to which supervision in this setting includes ‘gold standard’ supervision elements from efficacy trials (e.g., session review, model fidelity, outcome monitoring, skill-building) is unknown. The current federally-funded investigation leverages the Washington State Trauma-focused Cognitive Behavioral Therapy Initiative to describe usual supervision practices and test the impact of systematic implementation of gold standard supervision strategies on treatment fidelity and clinical outcomes. Methods/Design The study has two phases. We will conduct an initial descriptive study (Phase I) of supervision practices within public mental health in Washington State followed by a randomized controlled trial of gold standard supervision strategies (Phase II), with randomization at the clinician level (i.e., supervisors provide both conditions). Study participants will be 35 supervisors and 130 clinicians in community mental health centers. We will enroll one child per clinician in Phase I (N = 130) and three children per clinician in Phase II (N = 390). We use a multi-level mixed within- and between-subjects longitudinal design. Audio recordings of supervision and therapy sessions will be collected and coded throughout both phases. Child outcome data will be collected at the beginning of treatment and at three and six months into treatment. Discussion This study will provide insight into how supervisors can optimally support clinicians delivering evidence-based treatments. Phase I will provide descriptive information, currently unavailable in the literature, about commonly used supervision strategies in community mental health. The Phase II randomized controlled trial of gold standard supervision strategies is, to our knowledge, the first experimental study of gold standard supervision strategies in community mental health and will yield needed information about how to leverage supervision to improve clinician fidelity and client outcomes. Trial registration ClinicalTrials.gov NCT01800266 PMID:23937766

  8. Principled 'Bastard' Leadership? A Rejoinder to Gold, Evans, Earley, Halpin and Collarbone.

    ERIC Educational Resources Information Center

    Wright, Nigel

    2003-01-01

    Rejoinder to "Principled Principals" article (EA0000000). Asserts, for example, that offering second-order values such as questioning as evidence of principled leadership does not obviate "bastard leadership." (Contains 10 references.) (PKP)

  9. Gold Nanorods as Surface-Enhanced Raman Spectroscopy Substrates for Rapid and Sensitive Analysis of Allura Red and Sunset Yellow in Beverages.

    PubMed

    Ou, Yiming; Wang, Xiaohui; Lai, Keqiang; Huang, Yiqun; Rasco, Barbara A; Fan, Yuxia

    2018-03-21

    Synthetic colorants in food can be a potential threat to human health. In this study, surface-enhanced Raman spectroscopy (SERS) coupled with gold nanorods as substrates is proposed to analyze allura red and sunset yellow in beverages. The gold nanorods with different aspect ratios were synthesized, and their long-term stability, SERS activity, and the effect of the different salts on the SERS signal were investigated. The results demonstrate that gold nanorods have a satisfactory stability (stored up to 28 days). SERS coupled with gold nanorods exhibit stronger sensitivity. MgSO 4 was chosen to improve the SERS signal of sunset yellow, and no salts could enhance the SERS signal of allura red. The lowest concentration was 0.10 mg/L for both colorant standard solutions. The successful prediction results using SERS were much closer to those obtained by high-performance liquid chromatography for the sample in beverages. SERS combined with gold nanorods shows potential for analyzing food colorants and other food additives as a rapid, convenient, and sensitive method.

  10. TU-G-204-03: Dynamic CT Myocardial Perfusion Measurement Using First Pass Analysis and Maximum Slope Models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hubbard, L; Ziemer, B; Sadeghi, B

    Purpose: To evaluate the accuracy of dynamic CT myocardial perfusion measurement using first pass analysis (FPA) and maximum slope models. Methods: A swine animal model was prepared by percutaneous advancement of an angioplasty balloon into the proximal left anterior descending (LAD) coronary artery to induce varying degrees of stenosis. Maximal hyperaemia was achieved in the LAD with an intracoronary adenosine drip (240 µg/min). Serial microsphere and contrast (370 mg/mL iodine, 30 mL, 5mL/s) injections were made over a range of induced stenoses, and dynamic imaging was performed using a 320-row CT scanner at 100 kVp and 200 mA. The FPAmore » CT perfusion technique was used to make vessel-specific myocardial perfusion measurements. CT perfusion measurements using the FPA and maximum slope models were validated using colored microspheres as the reference gold standard. Results: Perfusion measurements using the FPA technique (P-FPA) showed good correlation with minimal offset when compared to perfusion measurements using microspheres (P- Micro) as the reference standard (P -FPA = 0.96 P-Micro + 0.05, R{sup 2} = 0.97, RMSE = 0.19 mL/min/g). In contrast, the maximum slope model technique (P-MS) was shown to underestimate perfusion when compared to microsphere perfusion measurements (P-MS = 0.42 P -Micro −0.48, R{sup 2} = 0.94, RMSE = 3.3 mL/min/g). Conclusion: The results indicate the potential for significant improvements in accuracy of dynamic CT myocardial perfusion measurement using the first pass analysis technique as compared with the standard maximum slope model.« less

  11. Gastric emptying of solids in children: reference values for the (13) C-octanoic acid breath test.

    PubMed

    Hauser, B; Roelants, M; De Schepper, J; Veereman, G; Caveliers, V; Devreker, T; De Greef, E; Vandenplas, Y

    2016-10-01

    (99m) Technetium scintigraphy ((99m) TS) is the 'gold standard' for measuring gastric emptying (GE), but it is associated with a radiation exposure. For this reason, the (13) C-octanoic acid breath test ((13) C-OBT) was developed for measuring GE of solids. The objective of this study was to determine normal values for gastric half-emptying time (t1/2 GE) of solids in healthy children. Gastric emptying of a standardized solid test meal consisting of a pancake evaluated with (99m) TS and (13) C-OBT was compared in 22 children aged between 1 and 15 years with upper gastrointestinal symptoms. Subsequently, the (13) C-OBT was used to determine normal values for GE of the same solid test meal in 120 healthy children aged between 1 and 17 years. The results showed a significant correlation (r = 0.748, p = 0.0001) between t1/2 GE measured with both techniques in the group of children with upper gastrointestinal symptoms. In the group of healthy children, mean t1/2 GE was 157.7 ± 54.0 min (range 71-415 min), but t1/2 GE decreased with age between 1 and 10 years and remained stable afterward. There was no influence of gender, weight, height, body mass index, and body surface area on t1/2 GE. Normal values for GE of solids measured with the (13) C-OBT using a standardized methodology were determined in healthy children. We propose to use this method and corresponding reference ranges to study GE of solids in children with gastrointestinal problems. © 2016 John Wiley & Sons Ltd.

  12. Development of an Electrochemical Immunosensor for Fumonisins Detection in Foods

    PubMed Central

    Kadir, Mohamad Kamal Abdul; Tothill, Ibtisam E.

    2010-01-01

    An electrochemical affinity sensor for the determination of fumonisins mycotoxins (Fms) using monoclonal antibody modified screen-printed gold electrode with carbon counter and silver-silver chloride pseudo-reference electrode is reported in this work. A direct competitive enzyme-linked immunosorbent assay (ELISA) was initially developed, exhibiting a detection limit of 100 µg·L-1 for fumonisins. This was then transferred to the surface of a bare gold screen-printed electrode (SPGE) and detection was performed by chronoamperometry, monitoring the reaction of 3,3’,5,5’-Tetramethylbenzidine dihydrochloride (TMB) and hydrogen peroxide (H2O2) catalysed by HRP at −100 mV potential vs. onboard Ag-AgCl pseudo-reference electrode. The immunosensor exhibited detection limit of 5 µg·L−1 fumonisins with a dynamic range from 1 µg·L−1–1000 µg·L−1. The sensor also performed well in extracted corn samples. PMID:22069591

  13. Better infrastructure for critical care trials: nomenclature, etymology, and informatics.

    PubMed

    Singh, Jeffrey M; Ferguson, Niall D

    2009-01-01

    The goals of this review article are to review the importance and value of standardized definitions in clinical research, as well as to propose the necessary tools and infrastructure needed to advance nosology and medial taxonomy to improve the quality of clinical trials in the field of critical care. We searched MEDLINE for relevant articles, reviewed those selected and their reference lists, and consulted personal files for relevant information. When the pathobiology of diseases is well understood, standard disease definitions can be extremely specific and precise; however, when the pathobiology of the disease is less well understood or more complex, biological markers may not be diagnostically useful or even available. In these cases, syndromic definitions effectively classify and group illnesses with similar symptoms and clinical signs. There is no clear gold standard for the diagnosis of many clinical entities in the intensive care unit, including notably both acute respiratory distress syndrome and sepsis. There are several types of consensus methods that can be used to explicate the judgmental approach that is often needed in these cases, including interactive or consensus groups, the nominal group technique, and the Delphi technique. Ideally, the definition development process will create clear and unambiguous language in which each definition accurately reflects the current understanding of the disease state. The development, implementation, evaluation, revision, and reevaluation of standardized definitions are keys for advancing the quality of clinical trials in the critical care arena.

  14. Visual characterization and diversity quantification of chemical libraries: 2. Analysis and selection of size-independent, subspace-specific diversity indices.

    PubMed

    Colliandre, Lionel; Le Guilloux, Vincent; Bourg, Stephane; Morin-Allory, Luc

    2012-02-27

    High Throughput Screening (HTS) is a standard technique widely used to find hit compounds in drug discovery projects. The high costs associated with such experiments have highlighted the need to carefully design screening libraries in order to avoid wasting resources. Molecular diversity is an established concept that has been used to this end for many years. In this article, a new approach to quantify the molecular diversity of screening libraries is presented. The approach is based on the Delimited Reference Chemical Subspace (DRCS) methodology, a new method that can be used to delimit the densest subspace spanned by a reference library in a reduced 2D continuous space. A total of 22 diversity indices were implemented or adapted to this methodology, which is used here to remove outliers and obtain a relevant cell-based partition of the subspace. The behavior of these indices was assessed and compared in various extreme situations and with respect to a set of theoretical rules that a diversity function should satisfy when libraries of different sizes have to be compared. Some gold standard indices are found inappropriate in such a context, while none of the tested indices behave perfectly in all cases. Five DRCS-based indices accounting for different aspects of diversity were finally selected, and a simple framework is proposed to use them effectively. Various libraries have been profiled with respect to more specific subspaces, which further illustrate the interest of the method.

  15. Bedside Diagnosis of Dysphagia: A Systematic Review

    PubMed Central

    O’Horo, John C.; Rogus-Pulia, Nicole; Garcia-Arguello, Lisbeth; Robbins, JoAnne; Safdar, Nasia

    2015-01-01

    Background Dysphagia is associated with aspiration, pneumonia and malnutrition, but remains challenging to identify at the bedside. A variety of exam protocols and maneuvers are commonly used, but the efficacy of these maneuvers is highly variable. Methods We conducted a comprehensive search of seven databases, including MEDLINE, EMBASE and Scopus, from each database’s earliest inception through June 5th, 2013. Studies reporting diagnostic performance of a bedside examination maneuver compared to a reference gold standard (videofluoroscopic swallow study [VFSS] or flexible endoscopic evaluation of swallowing with sensory testing [FEEST]) were included for analysis. From each study, data were abstracted based on the type of diagnostic method and reference standard study population and inclusion/exclusion characteristics, design and prediction of aspiration. Results The search strategy identified 38 articles meeting inclusion criteria. Overall, most bedside examinations lacked sufficient sensitivity to be used for screening purposes across all patient populations examined. Individual studies found dysphonia assessments, abnormal pharyngeal sensation assessments, dual axis accelerometry, and one description of water swallow testing to be sensitive tools, but none were reported as consistently sensitive. A preponderance of identified studies was in post-stroke adults, limiting the generalizability of results. Conclusions No bedside screening protocol has been shown to provide adequate predictive value for presence of aspiration. Several individual exam maneuvers demonstrated reasonable sensitivity, but reproducibility and consistency of these protocols was not established. More research is needed to design an optimal protocol for dysphagia detection. PMID:25581840

  16. Prediction of individual milk proteins including free amino acids in bovine milk using mid-infrared spectroscopy and their correlations with milk processing characteristics.

    PubMed

    McDermott, A; Visentin, G; De Marchi, M; Berry, D P; Fenelon, M A; O'Connor, P M; Kenny, O A; McParland, S

    2016-04-01

    The aim of this study was to evaluate the effectiveness of mid-infrared spectroscopy in predicting milk protein and free amino acid (FAA) composition in bovine milk. Milk samples were collected from 7 Irish research herds and represented cows from a range of breeds, parities, and stages of lactation. Mid-infrared spectral data in the range of 900 to 5,000 cm(-1) were available for 730 milk samples; gold standard methods were used to quantify individual protein fractions and FAA of these samples with a view to predicting these gold standard protein fractions and FAA levels with available mid-infrared spectroscopy data. Separate prediction equations were developed for each trait using partial least squares regression; accuracy of prediction was assessed using both cross validation on a calibration data set (n=400 to 591 samples) and external validation on an independent data set (n=143 to 294 samples). The accuracy of prediction in external validation was the same irrespective of whether undertaken on the entire external validation data set or just within the Holstein-Friesian breed. The strongest coefficient of correlation obtained for protein fractions in external validation was 0.74, 0.69, and 0.67 for total casein, total β-lactoglobulin, and β-casein, respectively. Total proteins (i.e., total casein, total whey, and total lactoglobulin) were predicted with greater accuracy then their respective component traits; prediction accuracy using the infrared spectrum was superior to prediction using just milk protein concentration. Weak to moderate prediction accuracies were observed for FAA. The greatest coefficient of correlation in both cross validation and external validation was for Gly (0.75), indicating a moderate accuracy of prediction. Overall, the FAA prediction models overpredicted the gold standard values. Near-unity correlations existed between total casein and β-casein irrespective of whether the traits were based on the gold standard (0.92) or mid-infrared spectroscopy predictions (0.95). Weaker correlations among FAA were observed than the correlations among the protein fractions. Pearson correlations between gold standard protein fractions and the milk processing characteristics of rennet coagulation time, curd firming time, curd firmness, heat coagulating time, pH, and casein micelle size were weak to moderate and ranged from -0.48 (protein and pH) to 0.50 (total casein and a30). Pearson correlations between gold standard FAA and these milk processing characteristics were also weak to moderate and ranged from -0.60 (Val and pH) to 0.49 (Val and K20). Results from this study indicate that mid-infrared spectroscopy has the potential to predict protein fractions and some FAA in milk at a population level. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  17. Machine Learning to Improve the Effectiveness of ANRS in Predicting HIV Drug Resistance.

    PubMed

    Singh, Yashik

    2017-10-01

    Human immunodeficiency virus infection and acquired immune deficiency syndrome (HIV/AIDS) is one of the major burdens of disease in developing countries, and the standard-of-care treatment includes prescribing antiretroviral drugs. However, antiretroviral drug resistance is inevitable due to selective pressure associated with the high mutation rate of HIV. Determining antiretroviral resistance can be done by phenotypic laboratory tests or by computer-based interpretation algorithms. Computer-based algorithms have been shown to have many advantages over laboratory tests. The ANRS (Agence Nationale de Recherches sur le SIDA) is regarded as a gold standard in interpreting HIV drug resistance using mutations in genomes. The aim of this study was to improve the prediction of the ANRS gold standard in predicting HIV drug resistance. A genome sequence and HIV drug resistance measures were obtained from the Stanford HIV database (http://hivdb.stanford.edu/). Feature selection was used to determine the most important mutations associated with resistance prediction. These mutations were added to the ANRS rules, and the difference in the prediction ability was measured. This study uncovered important mutations that were not associated with the original ANRS rules. On average, the ANRS algorithm was improved by 79% ± 6.6%. The positive predictive value improved by 28%, and the negative predicative value improved by 10%. The study shows that there is a significant improvement in the prediction ability of ANRS gold standard.

  18. Alternative Confidence Interval Methods Used in the Diagnostic Accuracy Studies

    PubMed Central

    Gülhan, Orekıcı Temel

    2016-01-01

    Background/Aim. It is necessary to decide whether the newly improved methods are better than the standard or reference test or not. To decide whether the new diagnostics test is better than the gold standard test/imperfect standard test, the differences of estimated sensitivity/specificity are calculated with the help of information obtained from samples. However, to generalize this value to the population, it should be given with the confidence intervals. The aim of this study is to evaluate the confidence interval methods developed for the differences between the two dependent sensitivity/specificity values on a clinical application. Materials and Methods. In this study, confidence interval methods like Asymptotic Intervals, Conditional Intervals, Unconditional Interval, Score Intervals, and Nonparametric Methods Based on Relative Effects Intervals are used. Besides, as clinical application, data used in diagnostics study by Dickel et al. (2010) has been taken as a sample. Results. The results belonging to the alternative confidence interval methods for Nickel Sulfate, Potassium Dichromate, and Lanolin Alcohol are given as a table. Conclusion. While preferring the confidence interval methods, the researchers have to consider whether the case to be compared is single ratio or dependent binary ratio differences, the correlation coefficient between the rates in two dependent ratios and the sample sizes. PMID:27478491

  19. Alternative Confidence Interval Methods Used in the Diagnostic Accuracy Studies.

    PubMed

    Erdoğan, Semra; Gülhan, Orekıcı Temel

    2016-01-01

    Background/Aim. It is necessary to decide whether the newly improved methods are better than the standard or reference test or not. To decide whether the new diagnostics test is better than the gold standard test/imperfect standard test, the differences of estimated sensitivity/specificity are calculated with the help of information obtained from samples. However, to generalize this value to the population, it should be given with the confidence intervals. The aim of this study is to evaluate the confidence interval methods developed for the differences between the two dependent sensitivity/specificity values on a clinical application. Materials and Methods. In this study, confidence interval methods like Asymptotic Intervals, Conditional Intervals, Unconditional Interval, Score Intervals, and Nonparametric Methods Based on Relative Effects Intervals are used. Besides, as clinical application, data used in diagnostics study by Dickel et al. (2010) has been taken as a sample. Results. The results belonging to the alternative confidence interval methods for Nickel Sulfate, Potassium Dichromate, and Lanolin Alcohol are given as a table. Conclusion. While preferring the confidence interval methods, the researchers have to consider whether the case to be compared is single ratio or dependent binary ratio differences, the correlation coefficient between the rates in two dependent ratios and the sample sizes.

  20. Protein Quantification by Derivatization-Free High-Performance Liquid Chromatography of Aromatic Amino Acids

    PubMed Central

    Hesse, Almut

    2016-01-01

    Amino acid analysis is considered to be the gold standard for quantitative peptide and protein analysis. Here, we would like to propose a simple HPLC/UV method based on a reversed-phase separation of the aromatic amino acids tyrosine (Tyr), phenylalanine (Phe), and optionally tryptophan (Trp) without any derivatization. The hydrolysis of the proteins and peptides was performed by an accelerated microwave technique, which needs only 30 minutes. Two internal standard compounds, homotyrosine (HTyr) and 4-fluorophenylalanine (FPhe) were used for calibration. The limit of detection (LOD) was estimated to be 0.05 µM (~10 µg/L) for tyrosine and phenylalanine at 215 nm. The LOD for a protein determination was calculated to be below 16 mg/L (~300 ng BSA absolute). Aromatic amino acid analysis (AAAA) offers excellent accuracy and a precision of about 5% relative standard deviation, including the hydrolysis step. The method was validated with certified reference materials (CRM) of amino acids and of a pure protein (bovine serum albumin, BSA). AAAA can be used for the quantification of aromatic amino acids, isolated peptides or proteins, complex peptide or protein samples, such as serum or milk powder, and peptides or proteins immobilized on solid supports. PMID:27559481

  1. Progesterone treatment for experimental stroke: an individual animal meta-analysis

    PubMed Central

    Wong, Raymond; Renton, Cheryl; Gibson, Claire L; Murphy, Stephanie J; Kendall, David A; Bath, Philip M W

    2013-01-01

    Preclinical studies suggest progesterone is neuroprotective after cerebral ischemia. The gold standard for assessing intervention effects across studies within and between subgroups is to use meta-analysis based on individual animal data (IAD). Preclinical studies of progesterone in experimental stroke were identified from searches of electronic databases and reference lists. Corresponding authors of papers of interest were contacted to obtain IAD and, if unavailable, summary data were obtained from the publication. Data are given as standardized mean differences (SMDs, continuous data) or odds ratios (binary data), with 95% confidence intervals (95% CIs). In an unadjusted analysis of IAD and summary data, progesterone reduced standardized lesion volume (SMD −0.766, 95% CI −1.173 to −0.358, P<0.001). Publication bias was apparent on visual inspection of a Begg's funnel plot on lesion volume and statistically using Egger's test (P=0.001). Using individual animal data alone, progesterone was associated with an increase in death in adjusted analysis (odds ratio 2.64, 95% CI 1.17 to 5.97, P=0.020). Although progesterone significantly reduced lesion volume, it also appeared to increase the incidence of death after experimental stroke, particularly in young ovariectomized female animals. Experimental studies must report the effect of interactions on death and on modifiers, such as age and sex. PMID:23838830

  2. Assessment of risk to human health from simultaneous exposure to multiple contaminants in an artisanal gold mine in Serra Pelada, Pará, Brazil.

    PubMed

    de Souza, Edna Santos; Texeira, Renato Alves; da Costa, Hercília Samara Cardoso; Oliveira, Fábio Júnior; Melo, Leônidas Carrijo Azevedo; do Carmo Freitas Faial, Kelson; Fernandes, Antonio Rodrigues

    2017-01-15

    Contamination of soil, water and plants caused by gold mining is of great societal concern because of the risk of environmental pollution and risk to human health. The aim of the present study was to evaluate the risk to human health from ingestion of As, Ba, Co, Cu, Cd, Cr, Ni, Pb, Se and Ni present in soil, sterile and mineralized waste, and water and plants at a gold mine in Serra Pelada, Pará, Brazil. Samples of soil, sterile and mineralized waste, water and plants were collected around an artisanal gold mine located in Serra Pelada. The mean concentrations of potentially toxic elements in the soil were higher than the soil quality reference values as defined in the legislation, which may be attributeable to past mining activities. Water from the area close to the mine exhibited As, Ba and Pb concentrations exceeding the reference values established by the World Health Organization, deemed unfit for human consumption. Plants exhibited high Pb concentrations, representing a food safety risk to the population. The mean hazard index (HI) values were below the acceptable limit (1.0) established by the United States Environmental Protection Agency, although the highest HI values observed for adults and children were higher than the respective acceptable limits. Environmental contamination and risk to human health were heterogeneous in the surroundings of the mine. Mitigation strategies need to be adopted to decrease the risks of contamination to the environment and to the local population. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Quantitative method for gait pattern detection based on fiber Bragg grating sensors

    NASA Astrophysics Data System (ADS)

    Ding, Lei; Tong, Xinglin; Yu, Lie

    2017-03-01

    This paper presents a method that uses fiber Bragg grating (FBG) sensors to distinguish the temporal gait patterns in gait cycles. Unlike most conventional methods that focus on electronic sensors to collect those physical quantities (i.e., strains, forces, pressure, displacements, velocity, and accelerations), the proposed method utilizes the backreflected peak wavelength from FBG sensors to describe the motion characteristics in human walking. Specifically, the FBG sensors are sensitive to external strain with the result that their backreflected peak wavelength will be shifted according to the extent of the influence of external strain. Therefore, when subjects walk in different gait patterns, the strains on FBG sensors will be different such that the magnitude of the backreflected peak wavelength varies. To test the reliability of the FBG sensor platform for gait pattern detection, the gold standard method using force-sensitive resistors (FSRs) for defining gait patterns is introduced as a reference platform. The reliability of the FBG sensor platform is determined by comparing the detection results between the FBG sensors and FSRs platforms. The experimental results show that the FBG sensor platform is reliable in gait pattern detection and gains high reliability when compared with the reference platform.

  4. [Validity of AUDIT test for detection of disorders related with alcohol consumption in women].

    PubMed

    Pérula-de Torres, Luis Angel; Fernández-García, José Angel; Arias-Vega, Raquel; Muriel-Palomino, María; Márquez-Rebollo, Encarnación; Ruiz-Moral, Roger

    2005-11-26

    Early detection of patients with alcohol problems is important in clinical practice. The AUDIT (Alcohol Use Disorders Identification Test) questionnaire is a valid tool for this aim, especially in the male population. The objective of this study was to validate how useful is this questionnaire in females patients and to assess their test cut-off point for the diagnosis of alcohol problems in women. 414 woman were recruited in 2 health center and specialized center for addiction treatment. The AUDIT test and a semistructured interview (SCAN as gold standard) were performed to all patients. Internal consistency and criteria validity was assessed. Cronbach alpha was 0.93 (95% confidence interval [CI], 0.921-0.941). When the DSM-IV was taken as reference the most useful cut-off point was 6 points, with 89.6% (95% CI, 76.11-96.02) sensitivity and 95.07% (95% CI, 92.18-96.97) specificity. When CIE-10 was taken as reference the sensitivity was 89.58% (95% CI, 76.56-96.10) and the specificity was 95.33% (95% CI, 92.48-97.17). AUDIT is a questionnaire with good psychometrics properties and is valid for detecting dependence and risk alcohol consumption in women.

  5. Reference Values of Pulse Wave Velocity in Healthy People from an Urban and Rural Argentinean Population

    PubMed Central

    Díaz, Alejandro; Galli, Cintia; Tringler, Matías; Ramírez, Agustín; Cabrera Fischer, Edmundo Ignacio

    2014-01-01

    In medical practice the reference values of arterial stiffness came from multicenter registries obtained in Asia, USA, Australia and Europe. Pulse wave velocity (PWV) is the gold standard method for arterial stiffness quantification; however, in South America, there are few population-based studies. In this research PWV was measured in healthy asymptomatic and normotensive subjects without history of hypertension in first-degree relatives. Normal PWV and the 95% confidence intervals values were obtained in 780 subjects (39.8 ± 18.5 years) divided into 7 age groups (10–98 years). The mean PWV found was 6.84 m/s ± 1.65. PWV increases linearly with aging with a high degree of correlation (r 2 = 0.61; P < 0.05) with low dispersion in younger subjects. PWV progressively increases 6–8% with each decade of life; this tendency is more pronounced after 50 years. A significant increase of PWV over 50 years was demonstrated. This is the first population-based study from urban and rural people of Argentina that provides normal values of the PWV in healthy, normotensive subjects without family history of hypertension. Moreover, the age dependence of PWV values was confirmed. PMID:25215227

  6. Noncontact spirometry with a webcam

    NASA Astrophysics Data System (ADS)

    Liu, Chenbin; Yang, Yuting; Tsow, Francis; Shao, Dangdang; Tao, Nongjian

    2017-05-01

    We present an imaging-based method for noncontact spirometry. The method tracks the subtle respiratory-induced shoulder movement of a subject, builds a calibration curve, and determines the flow-volume spirometry curve and vital respiratory parameters, including forced expiratory volume in the first second, forced vital capacity, and peak expiratory flow rate. We validate the accuracy of the method by comparing the data with those simultaneously recorded with a gold standard reference method and examine the reliability of the noncontact spirometry with a pilot study including 16 subjects. This work demonstrates that the noncontact method can provide accurate and reliable spirometry tests with a webcam. Compared to the traditional spirometers, the present noncontact spirometry does not require using a spirometer, breathing into a mouthpiece, or wearing a nose clip, thus making spirometry test more easily accessible for the growing population of asthma and chronic obstructive pulmonary diseases.

  7. Rare presentation of a testicular angiofibroma treated with testis sparing surgery.

    PubMed

    Leone, Luca; Fulvi, Paola; Sbrollini, Giulia; Filosa, Alessandra; Caraceni, Enrico; Marronaro, Angelo; Galosi, Andrea B

    2016-12-30

    Testicular benign tumors are very rare (< 5%). Testicular Angiofibroma (AF) is one of those, however the gold standard of treatment and follow-up is still unclear. A 47 years-old man with only one functioning testis was referred to our clinic for a palpable right testicular mass and atrophic contralateral testis. Patient underwent testis-sparing surgery with inguinal approach and intraoperative frozen sections examination with diagnosis of AF. Final histology confirmed AF. Post-operative follow-up was uneventful. Clinical and ultrasonographic follow-up was negative after 8 months. We report a conservative surgery in a patient with AF of the solitary testis. AF is a benign para-testicular fibrous neoplasm that could be misinterpreted as malignant tumor and treated with orchiectomy. Testis-sparing surgery is recommended in this case with intraoperative pathological examination. The excision of the mass is enough but in front of a possible recurrence a long follow-up is advisable.

  8. The search for causal inferences: using propensity scores post hoc to reduce estimation error with nonexperimental research.

    PubMed

    Tumlinson, Samuel E; Sass, Daniel A; Cano, Stephanie M

    2014-03-01

    While experimental designs are regarded as the gold standard for establishing causal relationships, such designs are usually impractical owing to common methodological limitations. The objective of this article is to illustrate how propensity score matching (PSM) and using propensity scores (PS) as a covariate are viable alternatives to reduce estimation error when experimental designs cannot be implemented. To mimic common pediatric research practices, data from 140 simulated participants were used to resemble an experimental and nonexperimental design that assessed the effect of treatment status on participant weight loss for diabetes. Pretreatment participant characteristics (age, gender, physical activity, etc.) were then used to generate PS for use in the various statistical approaches. Results demonstrate how PSM and using the PS as a covariate can be used to reduce estimation error and improve statistical inferences. References for issues related to the implementation of these procedures are provided to assist researchers.

  9. Noncontact spirometry with a webcam.

    PubMed

    Liu, Chenbin; Yang, Yuting; Tsow, Francis; Shao, Dangdang; Tao, Nongjian

    2017-05-01

    We present an imaging-based method for noncontact spirometry. The method tracks the subtle respiratory-induced shoulder movement of a subject, builds a calibration curve, and determines the flow-volume spirometry curve and vital respiratory parameters, including forced expiratory volume in the first second, forced vital capacity, and peak expiratory flow rate. We validate the accuracy of the method by comparing the data with those simultaneously recorded with a gold standard reference method and examine the reliability of the noncontact spirometry with a pilot study including 16 subjects. This work demonstrates that the noncontact method can provide accurate and reliable spirometry tests with a webcam. Compared to the traditional spirometers, the present noncontact spirometry does not require using a spirometer, breathing into a mouthpiece, or wearing a nose clip, thus making spirometry test more easily accessible for the growing population of asthma and chronic obstructive pulmonary diseases.

  10. Monitoring the hatch time of individual chicken embryos.

    PubMed

    Romanini, C E B; Exadaktylos, V; Tong, Q; McGonnel, I; Demmers, T G M; Bergoug, H; Eterradossi, N; Roulston, N; Garain, P; Bahr, C; Berckmans, D

    2013-02-01

    This study investigated variations in eggshell temperature (T(egg)) during the hatching process of broiler eggs. Temperature sensors monitored embryo temperature by registering T(egg) every minute. Measurements carried out on a sample of 40 focal eggs revealed temperature drops between 2 to 6°C during the last 3 d of incubation. Video cameras recorded the hatching process and served as the gold standard reference for manually labeling the hatch times of chicks. Comparison between T(egg) drops and the hatch time of individuals revealed a time synchronization with 99% correlation coefficient and an absolute average time difference up to 25 min. Our findings suggest that attaching temperature sensors to eggshells is a precise tool for monitoring the hatch time of individual chicks. Individual hatch monitoring registers the biological age of chicks and facilitates an accurate and reliable means to count hatching results and manage the hatch window.

  11. Perovskite Solar Cells with Large-Area CVD-Graphene for Tandem Solar Cells.

    PubMed

    Lang, Felix; Gluba, Marc A; Albrecht, Steve; Rappich, Jörg; Korte, Lars; Rech, Bernd; Nickel, Norbert H

    2015-07-16

    Perovskite solar cells with transparent contacts may be used to compensate for thermalization losses of silicon solar cells in tandem devices. This offers a way to outreach stagnating efficiencies. However, perovskite top cells in tandem structures require contact layers with high electrical conductivity and optimal transparency. We address this challenge by implementing large-area graphene grown by chemical vapor deposition as a highly transparent electrode in perovskite solar cells, leading to identical charge collection efficiencies. Electrical performance of solar cells with a graphene-based contact reached those of solar cells with standard gold contacts. The optical transmission by far exceeds that of reference devices and amounts to 64.3% below the perovskite band gap. Finally, we demonstrate a four-terminal tandem device combining a high band gap graphene-contacted perovskite top solar cell (Eg = 1.6 eV) with an amorphous/crystalline silicon bottom solar cell (Eg = 1.12 eV).

  12. Acetylcholinesterase inhibition-based biosensor for aluminum(III) chronoamperometric determination in aqueous media.

    PubMed

    Barquero-Quirós, Miriam; Domínguez-Renedo, Olga; Alonso-Lomillo, Maria Asunción; Arcos-Martínez, María Julia

    2014-05-07

    A novel amperometric biosensor for the determination of Al(III) based on the inhibition of the enzyme acetylcholinesterase has been developed. The immobilization of the enzyme was performed on screen-printed carbon electrodes modified with gold nanoparticles. The oxidation signal of acetylthiocholine iodide enzyme substrate was affected by the presence of Al(III) ions leading to a decrease in the amperometric current. The developed system has a detection limit of 2.1 ± 0.1 μM for Al(III). The reproducibility of the method is 8.1% (n = 4). Main interferences include Mo(VI), W(VI) and Hg(II) ions. The developed method was successfully applied to the determination of Al(III) in spiked tap water . The analysis of a certified standard reference material was also carried out. Both results agree with the certified values considering the respective associated uncertainties.

  13. Acetylcholinesterase Inhibition-Based Biosensor for Aluminum(III) Chronoamperometric Determination in Aqueous Media

    PubMed Central

    Barquero-Quirós, Miriam; Domínguez-Renedo, Olga; Alonso-Lomillo, Maria Asunción; Arcos-Martínez, María Julia

    2014-01-01

    A novel amperometric biosensor for the determination of Al(III) based on the inhibition of the enzyme acetylcholinesterase has been developed. The immobilization of the enzyme was performed on screen-printed carbon electrodes modified with gold nanoparticles. The oxidation signal of acetylthiocholine iodide enzyme substrate was affected by the presence of Al(III) ions leading to a decrease in the amperometric current. The developed system has a detection limit of 2.1 ± 0.1 μM for Al(III). The reproducibility of the method is 8.1% (n = 4). Main interferences include Mo(VI), W(VI) and Hg(II) ions. The developed method was successfully applied to the determination of Al(III) in spiked tap water. The analysis of a certified standard reference material was also carried out. Both results agree with the certified values considering the respective associated uncertainties. PMID:24811076

  14. Development of a qualitative real-time PCR method to detect 19 targets for identification of genetically modified organisms.

    PubMed

    Peng, Cheng; Wang, Pengfei; Xu, Xiaoli; Wang, Xiaofu; Wei, Wei; Chen, Xiaoyun; Xu, Junfeng

    2016-01-01

    As the amount of commercially available genetically modified organisms (GMOs) grows recent years, the diversity of target sequences for molecular detection techniques are eagerly needed. Considered as the gold standard for GMO analysis, the real-time PCR technology was optimized to produce a high-throughput GMO screening method. With this method we can detect 19 transgenic targets. The specificity of the assays was demonstrated to be 100 % by the specific amplification of DNA derived from reference material from 20 genetically modified crops and 4 non modified crops. Furthermore, most assays showed a very sensitive detection, reaching the limit of ten copies. The 19 assays are the most frequently used genetic elements present in GM crops and theoretically enable the screening of the known GMO described in Chinese markets. Easy to use, fast and cost efficient, this method approach fits the purpose of GMO testing laboratories.

  15. OSA severity assessment based on sleep breathing analysis using ambient microphone.

    PubMed

    Dafna, E; Tarasiuk, A; Zigel, Y

    2013-01-01

    In this paper, an audio-based system for severity estimation of obstructive sleep apnea (OSA) is proposed. The system estimates the apnea-hypopnea index (AHI), which is the average number of apneic events per hour of sleep. This system is based on a Gaussian mixture regression algorithm that was trained and validated on full-night audio recordings. Feature selection process using a genetic algorithm was applied to select the best features extracted from time and spectra domains. A total of 155 subjects, referred to in-laboratory polysomnography (PSG) study, were recruited. Using the PSG's AHI score as a gold-standard, the performances of the proposed system were evaluated using a Pearson correlation, AHI error, and diagnostic agreement methods. Correlation of R=0.89, AHI error of 7.35 events/hr, and diagnostic agreement of 77.3% were achieved, showing encouraging performances and a reliable non-contact alternative method for OSA severity estimation.

  16. Methodology and application of flow cytometry for investigation of human malaria parasites.

    PubMed

    Grimberg, Brian T

    2011-03-31

    Historically, examinations of the inhibition of malaria parasite growth/invasion, whether using drugs or antibodies, have relied on the use of microscopy or radioactive hypoxanthine uptake. These are considered gold standards for measuring the effectiveness of antimalarial treatments, however, these methods have well known shortcomings. With the advent of flow cytometry coupled with the use of fluorescent DNA stains allowed for increased speed, reproducibility, and qualitative estimates of the effectiveness of antibodies and drugs to limit malaria parasite growth which addresses the challenges of traditional techniques. Because materials and machines available to research facilities are so varied, different methods have been developed to investigate malaria parasites by flow cytometry. This review is intended to serve as a reference guide for advanced users and importantly, as a primer for new users, to support expanded use and improvements to malaria flow cytometry, particularly in endemic countries. Copyright © 2011 Elsevier B.V. All rights reserved.

  17. Artificial intelligence techniques for automatic screening of amblyogenic factors.

    PubMed

    Van Eenwyk, Jonathan; Agah, Arvin; Giangiacomo, Joseph; Cibis, Gerhard

    2008-01-01

    To develop a low-cost automated video system to effectively screen children aged 6 months to 6 years for amblyogenic factors. In 1994 one of the authors (G.C.) described video vision development assessment, a digitizable analog video-based system combining Brückner pupil red reflex imaging and eccentric photorefraction to screen young children for amblyogenic factors. The images were analyzed manually with this system. We automated the capture of digital video frames and pupil images and applied computer vision and artificial intelligence to analyze and interpret results. The artificial intelligence systems were evaluated by a tenfold testing method. The best system was the decision tree learning approach, which had an accuracy of 77%, compared to the "gold standard" specialist examination with a "refer/do not refer" decision. Criteria for referral were strabismus, including microtropia, and refractive errors and anisometropia considered to be amblyogenic. Eighty-two percent of strabismic individuals were correctly identified. High refractive errors were also correctly identified and referred 90% of the time, as well as significant anisometropia. The program was less correct in identifying more moderate refractive errors, below +5 and less than -7. Although we are pursuing a variety of avenues to improve the accuracy of the automated analysis, the program in its present form provides acceptable cost benefits for detecting ambylogenic factors in children aged 6 months to 6 years.

  18. Utilisation of Quartz Crystal Microbalance Sensors with Dissipation (QCM-D) for a Clauss Fibrinogen Assay in Comparison with Common Coagulation Reference Methods.

    PubMed

    Oberfrank, Stephanie; Drechsel, Hartmut; Sinn, Stefan; Northoff, Hinnak; Gehring, Frank K

    2016-02-24

    The determination of fibrinogen levels is one of the most important coagulation measurements in medicine. It plays a crucial part in diagnostic and therapeutic decisions, often associated with time-critical conditions. The commonly used measurement is the Clauss fibrinogen assay (CFA) where plasma is activated by thrombin reagent and which is conducted by mechanical/turbidimetric devices. As quartz crystal microbalance sensors with dissipation (QCM-D) based devices have a small footprint, can be operated easily and allow measurements independently from sample transportation time, laboratory location, availability and opening hours, they offer a great opportunity to complement laboratory CFA measurements. Therefore, the objective of the work was to (1) transfer the CFA to the QCM-D method; (2) develop an easy, time- and cost-effective procedure and (3) compare the results with references. Different sensor coatings (donor's own plasma; gold surface) and different QCM-D parameters (frequency signal shift; its calculated turning point; dissipation signal shift) were sampled. The results demonstrate the suitability for a QCM-D-based CFA in physiological fibrinogen ranges. Results were obtained in less than 1 min and in very good agreement with a standardized reference (Merlin coagulometer). The results provide a good basis for further investigation and pave the way to a possible application of QCM-D in clinical and non-clinical routine in the medical field.

  19. Diode Laser Clinical Efficacy and Mini-Invasivity in Surgical Exposure of Impacted Teeth.

    PubMed

    Migliario, Mario; Rizzi, Manuela; Lucchina, Alberta Greco; Renò, Filippo

    2016-11-01

    The gold standard to arrange impacted teeth in the dental arch is represented by a surgical approach followed by orthodontic traction force application. In the literature, many surgical approaches are proposed to reach such a scope. The aim of the present study is to demonstrate how laser technique could positively assist surgical approaches.Study population was composed by 16 patients undergoing orthodontic treatment of 20 impacted teeth. In 10 patients (population A) surgical exposure of the impacted teeth was performed using a 980 nm diode laser, while in the other 10 patients (population B), surgical incision was performed using a traditional lancet.Only 3 patients of the population A needed local anesthesia for surgical procedure while the remaining 7 patients reported only faint pain during surgery. Two patients referred postsurgical pain (numerical rating scale average value = 2) and needed to take analgesics. None of the patients showed other postsurgical side effects (bleeding, edema).All population B patients needed infiltrative anesthesia and referred postsurgical pain (numerical rating scale average value >4) treated with analgesics. Moreover, in such population, 4 patients referred lips edema while 4 showed bleeding and 6 needed surgical sutures of soft tissues.The lack of side effects of laser surgical approach to expose impacted teeth must persuade dental practitioners to choose such a clinical approach to closed surgical approach every time it is possible.

  20. Utilisation of Quartz Crystal Microbalance Sensors with Dissipation (QCM-D) for a Clauss Fibrinogen Assay in Comparison with Common Coagulation Reference Methods

    PubMed Central

    Oberfrank, Stephanie; Drechsel, Hartmut; Sinn, Stefan; Northoff, Hinnak; Gehring, Frank K.

    2016-01-01

    The determination of fibrinogen levels is one of the most important coagulation measurements in medicine. It plays a crucial part in diagnostic and therapeutic decisions, often associated with time-critical conditions. The commonly used measurement is the Clauss fibrinogen assay (CFA) where plasma is activated by thrombin reagent and which is conducted by mechanical/turbidimetric devices. As quartz crystal microbalance sensors with dissipation (QCM-D) based devices have a small footprint, can be operated easily and allow measurements independently from sample transportation time, laboratory location, availability and opening hours, they offer a great opportunity to complement laboratory CFA measurements. Therefore, the objective of the work was to (1) transfer the CFA to the QCM-D method; (2) develop an easy, time- and cost-effective procedure and (3) compare the results with references. Different sensor coatings (donor’s own plasma; gold surface) and different QCM-D parameters (frequency signal shift; its calculated turning point; dissipation signal shift) were sampled. The results demonstrate the suitability for a QCM-D-based CFA in physiological fibrinogen ranges. Results were obtained in less than 1 min and in very good agreement with a standardized reference (Merlin coagulometer). The results provide a good basis for further investigation and pave the way to a possible application of QCM-D in clinical and non-clinical routine in the medical field. PMID:26927107

  1. Geologic map of the Zarkashan-Anguri copper and gold deposits, Ghazni Province, Afghanistan, modified from the 1968 original map compilation of E.P. Meshcheryakov and V.P. Sayapin

    USGS Publications Warehouse

    Peters, Stephen G.; Stettner, Will R.; Masonic, Linda M.; Moran, Thomas W.

    2011-01-01

    This map is a modified version of Geological map of the area of Zarkashan-Anguri gold deposits, scale 1:50,000, which was compiled by E.P. Meshcheryakov and V.P. Sayapin in 1968. Scientists from the U.S. Geological Survey, in cooperation with the Afghan Geological Survey and the Task Force for Business and Stability Operations of the U.S. Department of Defense, studied the original document and related reports and also visited the field area in April 2010. This modified map, which includes a cross section, illustrates the geologic setting of the Zarkashan-Anguri copper and gold deposits. The map reproduces the topology (contacts, faults, and so forth) of the original Soviet map and cross section and includes modifications based on our examination of that and other documents, and based on observations made and sampling undertaken during our field visit. (Refer to the Introduction and the References in the Map PDF for an explanation of our methodology and for complete citations of the original map and related reports.) Elevations on the cross section are derived from the original Soviet topography and may not match the newer topography used on the current map.

  2. Surface plasmon resonance-induced photoactivation of gold nanoparticles as bactericidal agents against methicillin-resistant Staphylococcus aureus

    PubMed Central

    Mocan, Lucian; Ilie, Ioana; Matea, Cristian; Tabaran, Flaviu; Kalman, Ersjebet; Iancu, Cornel; Mocan, Teodora

    2014-01-01

    Systemic infections caused by methicillin-resistant Staphylococcus aureus (MRSA) and other bacteria are responsible for millions of deaths worldwide, and much of this mortality is due to the rise of antibiotic-resistant organisms as a result of natural selection. Gold nanoparticles synthesized using the standard wet chemical procedure were photoexcited using an 808 nm 2 W laser diode and further administered to MRSA bacteria. Flow cytometry, transmission electron microscopy, contrast phase microscopy, and fluorescence microscopy combined with immunochemical staining were used to examine the interaction of the photoexcited gold nano-particles with MRSA bacteria. We show here that phonon–phonon interactions following laser photoexcitation of gold nanoparticles exhibit increased MRSA necrotic rates at low concentrations and short incubation times compared with MRSA treated with gold nanoparticles alone. These unique data may represent a step forward in the study of bactericidal effects of various nanomaterials, with applications in biology and medicine. PMID:24711697

  3. Method development for speciation analysis of nanoparticle and ionic forms of gold in biological samples by high performance liquid chromatography hyphenated to inductively coupled plasma mass spectrometry

    NASA Astrophysics Data System (ADS)

    Malejko, Julita; Świerżewska, Natalia; Bajguz, Andrzej; Godlewska-Żyłkiewicz, Beata

    2018-04-01

    A new method based on coupling high performance liquid chromatography (HPLC) to inductively coupled plasma mass spectrometry (ICP MS) has been developed for the speciation analysis of gold nanoparticles (AuNPs) and dissolved gold species (Au(III)) in biological samples. The column type, the composition and the flow rate of the mobile phase were carefully investigated in order to optimize the separation conditions. The usefulness of two polymeric reversed phase columns (PLRP-S with 100 nm and 400 nm pore size) to separate gold species were investigated for the first time. Under the optimal conditions (PLRP-S400 column, 10 mmol L-1 SDS and 5% methanol as the mobile phase, 0.5 mL min-1 flow rate), detection limits of 2.2 ng L-1 for Au(III), 2.8 ng L-1 for 10 nm AuNPs and 3.7 ng L-1 for 40 nm AuNPs were achieved. The accuracy of the method was proved by analysis of reference material RM 8011 (NIST) of gold nanoparticles of nominal diameter of 10 nm. The HPLC-ICP MS method has been successfully applied to the detection and size characterization of gold species in lysates of green algae Acutodesmus obliquus, typical representative of phytoplankton flora, incubated with 10 nm AuNPs or Au(III).

  4. Gold Standard Tests

    DTIC Science & Technology

    2001-06-01

    important issues need to be understood. Caloric Irrigation: Irrigation of both ears with water of 30 and 44 degree Celsius is the standard Anamnesis ... anamnesis , falls short. In the usual because there are many factors which may clinical situation, a vestibular deficit is suspected if influence the final

  5. There's gold in them thar' databases.

    PubMed

    Gillespie, G

    2000-11-01

    Some health care organizations are using sophisticated data mining applications to unearth hidden truths buried in their online clinical and financial information. But the lack of a standard clinical vocabulary and standard work processes is an obstacle CIOs must blast through to reach their treasure.

  6. Comparative study of photothermolysis of cancer cells with nuclear-targeted or cytoplasm-targeted gold nanospheres: continuous wave or pulsed lasers

    NASA Astrophysics Data System (ADS)

    Huang, Xiaohua; Kang, Bin; Qian, Wei; Mackey, Megan A.; Chen, Po C.; Oyelere, Adegboyega K.; El-Sayed, Ivan H.; El-Sayed, Mostafa A.

    2010-09-01

    We conduct a comparative study on the efficiency and cell death pathways of continuous wave (cw) and nanosecond pulsed laser photothermal cancer therapy using gold nanospheres delivered to either the cytoplasm or nucleus of cancer cells. Cytoplasm localization is achieved using arginine-glycine-aspartate peptide modified gold nanospheres, which target integrin receptors on the cell surface and are subsequently internalized by the cells. Nuclear delivery is achieved by conjugating the gold nanospheres with nuclear localization sequence peptides originating from the simian virus. Photothermal experiments show that cell death can be induced with a single pulse of a nanosecond laser more efficiently than with a cw laser. When the cw laser is applied, gold nanospheres localized in the cytoplasm are more effective in inducing cell destruction than gold nanospheres localized at the nucleus. The opposite effect is observed when the nanosecond pulsed laser is used, suggesting that plasmonic field enhancement of the nonlinear absorption processes occurs at high localization of gold nanospheres at the nucleus. Cell death pathways are further investigated via a standard apoptosis kit to show that the cell death mechanisms depend on the type of laser used. While the cw laser induces cell death via apoptosis, the nanosecond pulsed laser leads to cell necrosis. These studies add mechanistic insight to gold nanoparticle-based photothermal therapy of cancer.

  7. Oblique map of the northern Sierra Nevada, California, showing location of gold-bearing areas

    USGS Publications Warehouse

    Alpha, T.R.; Dodge, F.C.W.; Bliss, J.D.

    1987-01-01

    Locations of lode gold prospects and mines shown on the map were obtained from the U.S. Geological Survey's Mineral Resource Data System (MRDS), a computerized mineral-resource information file, and plotted in their respective locations (D.F. Huber, written commun., 1986). Some locations from two northern counties, missing from the MRDS retrival, were added. The twenty lode mines believed to be the most productive are cited in table 1. A total of nearly 4,000 sites, including both prospects and mines, were initially plotted, but about a third of those were obscured by topography on the oblique map. Locations of Tertiary river channels and gold-dredging fields were taken from published general references modified by examining specific sources and by cursory field examination. Seven of the major dredge fields are identified in table 2.

  8. Improving the contact resistance at low force using gold coated carbon nanotube surfaces

    NASA Astrophysics Data System (ADS)

    McBride, J. W.; Yunus, E. M.; Spearing, S. M.

    2010-04-01

    Investigations to determine the electrical contact performance under repeated cycles at low force conditions for carbon-nanotube (CNT) coated surfaces were performed. The surfaces under investigation consisted of multi-walled CNT synthesized on a silicon substrate and coated with a gold film. These planar surfaces were mounted on the tip of a PZT actuator and contacted with a plated Au hemispherical probe. The dynamic applied force used was 1 mN. The contact resistance (Rc) of these surfaces was investigated with the applied force and with repeated loading cycles performed for stability testing. The surfaces were compared with a reference Au-Au contact under the same experimental conditions. This initial study shows the potential for the application of gold coated CNT surfaces as an interface in low force electrical contact applications.

  9. Neutron transfer in the C 13 + Au 197 reaction from gold isotope residuals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Daub, B. H.; Bleuel, D. L.; Wiedeking, M.

    Residual gold nuclei were produced in this paper via neutron transfer at multiple energies using a 130-MeV 13C beam incident on a stacked-foil target consisting of alternating layers of 197Au and 27Al. Production cross sections, over an energy range of 56 to 129 MeV, for seven gold isotopes and two gold isomers were determined through activation analysis. By using the Wilczynski binary transfer model with a modified version of the recoil formula and a standard evaporation model, we were able to reproduce the isotopic production cross sections at high beam energy, with some disagreement at lower beam energies. Finally, thismore » limiting angular momentum model does not predict the transfer of sufficient angular momentum to reproduce the observed isomeric populations.« less

  10. Neutron transfer in the C 13 + Au 197 reaction from gold isotope residuals

    DOE PAGES

    Daub, B. H.; Bleuel, D. L.; Wiedeking, M.; ...

    2017-08-01

    Residual gold nuclei were produced in this paper via neutron transfer at multiple energies using a 130-MeV 13C beam incident on a stacked-foil target consisting of alternating layers of 197Au and 27Al. Production cross sections, over an energy range of 56 to 129 MeV, for seven gold isotopes and two gold isomers were determined through activation analysis. By using the Wilczynski binary transfer model with a modified version of the recoil formula and a standard evaporation model, we were able to reproduce the isotopic production cross sections at high beam energy, with some disagreement at lower beam energies. Finally, thismore » limiting angular momentum model does not predict the transfer of sufficient angular momentum to reproduce the observed isomeric populations.« less

  11. Comparison of the metal-to-ceramic bond strengths of four noble alloys with press-on-metal and conventional porcelain layering techniques.

    PubMed

    Khmaj, Mofida R; Khmaj, Abdulfatah B; Brantley, William A; Johnston, William M; Dasgupta, Tridib

    2014-11-01

    New noble alloys for metal ceramic restorations introduced by manufacturers are generally lower-cost alternatives to traditional higher-gold alloys. Information about the metal-to-ceramic bond strength for these alloys, which is needed for rational clinical selection, is often lacking. The purpose of this study was to evaluate the bond strength of 4 recently introduced noble alloys by using 2 techniques for porcelain application. Aquarius Hard (high-gold: 86.1 gold, 8.5 platinum, 2.6 palladium, 1.4 indium; values in wt. %), Evolution Lite (reduced-gold: 40.3 gold, 39.3 palladium, 9.3 indium, 9.2 silver, 1.8 gallium), Callisto 75 Pd (palladium-silver containing gold: 75.2 palladium, 7.1 silver, 2.5 gold, 9.3 tin, 1.0 indium), and Aries, (conventional palladium-silver: 63.7 palladium, 26.0 silver, 7.0 tin, 1.8 gallium, 1.5 indium) were selected for bonding to leucite-containing veneering porcelains. Ten metal ceramic specimens that met dimensional requirements for International Organization for Standardization (ISO) Standard 9693 were prepared for each alloy by using conventional porcelain layering and press-on-metal methods. The 3-point bending test in ISO Standard 9693 was used to determine bond strength. Values were compared with 2-way ANOVA (maximum likelihood analysis, SAS Mixed Procedure) and the Tukey test (α=.05). Means (standard deviations) for bond strength with conventional porcelain layering were as follows: Aquarius Hard (50.7 ±5.5 MPa), Evolution Lite (40.2 ±3.3 MPa), Callisto 75 Pd (37.2 ±3.9 MPa), and Aries (34.0 ±4.9 MPa). For the press-on-metal technique, bond strength results were as follows: Aquarius Hard (33.7 ±11.5 MPa), Evolution Lite (34.9 ±4.5 MPa), Callisto 75 Pd (37.2 ±11.9 MPa), and Aries (30.7 ±10.8 MPa). From statistical analyses, the following 3 significant differences were found for metal-to-ceramic bond strength: the bond strength for Aquarius Hard was significantly higher for conventional porcelain layers compared with the press-on-metal technique; the bond strength for Aquarius Hard with conventional porcelain layers was significantly higher than the bond strengths for the other 3 alloys with conventional porcelain layers; and the bond strength for Aquarius Hard with conventional porcelain layers was significantly higher than the bond strength for Callisto 75 Pd with conventional porcelain layers and the other 3 alloys with the press-on-metal technique. For both conventional layering and press-on-metal techniques, all 4 noble alloys had a mean metal-to-ceramic bond strength that substantially exceeded the 25 MPa minimum in the ISO Standard 9693. The results for Aries support the manufacturer's recommendation not to use the press-on-metal technique for alloys that contain more than 10% silver. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  12. Oncology Gold Standard™ practical consensus recommendations 2016 for treatment of advanced clear cell renal cell carcinoma

    PubMed Central

    Batra, U; Parikh, PM; Prabhash, K; Tongaonkar, HB; Chibber, P; Dabkara, D; Deshmukh, C; Ghadyalpatil, N; Hingmire, S; Joshi, A; Raghunath, SK; Rajappa, S; Rajendranath, R; Rawal, SK; Singh, Manisha; Singh, R; Somashekhar, SP; Sood, R

    2016-01-01

    The Oncology Gold Standard (OGS) Expert Group on renal cell carcinoma (RCC) developed the consensus statement to provide community oncologists practical guidelines on the management of advanced clear cell (cc) RCC using published evidence, practical experience of experts in real life management, and results of a nationwide survey involving 144 health-care professionals. Six broad question categories containing 33 unique questions cover major situations in the routine management of RCC. This document serves as a ready guide for the standard of care to optimize outcome. The table of “Take Home Messages” at the end is a convenient tool for busy practitioners. PMID:28032079

  13. Hybridization chain reaction-based colorimetric aptasensor of adenosine 5'-triphosphate on unmodified gold nanoparticles and two label-free hairpin probes.

    PubMed

    Gao, Zhuangqiang; Qiu, Zhenli; Lu, Minghua; Shu, Jian; Tang, Dianping

    2017-03-15

    This work designs a new label-free aptasensor for the colorimetric determination of small molecules (adenosine 5'-triphosphate, ATP) by using visible gold nanoparticles as the signal-generation tags, based on target-triggered hybridization chain reaction (HCR) between two hairpin DNA probes. The assay is carried out referring to the change in the color/absorbance by salt-induced aggregation of gold nanoparticles after the interaction with hairpins, gold nanoparticles and ATP. To construct such an assay system, two hairpin DNA probes with a short single-stranded DNA at the sticky end are utilized for interaction with gold nanoparticles. In the absence of target ATP, the hairpin DNA probes can prevent gold nanoparticles from the salt-induced aggregation through the interaction of the single-stranded DNA at the sticky end with gold nanoparticles. Upon target ATP introduction, the aptamer-based hairpin probe is opened to expose a new sticky end for the strand-displacement reaction with another complementary hairpin, thus resulting in the decreasing single-stranded DNA because of the consumption of hairpins. In this case, gold nanoparticles are uncovered owing to the formation of double-stranded DNA, which causes their aggregation upon addition of the salt, thereby leading to the change in the red-to-blue color. Under the optimal conditions, the HCR-based colorimetric assay presents good visible color or absorbance responses for the determination of target ATP at a concentration as low as 1.0nM. Importantly, the methodology can be further extended to quantitatively or qualitatively monitor other small molecules or biotoxins by changing the sequence of the corresponding aptamer. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. PyGOLD: a python based API for docking based virtual screening workflow generation.

    PubMed

    Patel, Hitesh; Brinkjost, Tobias; Koch, Oliver

    2017-08-15

    Molecular docking is one of the successful approaches in structure based discovery and development of bioactive molecules in chemical biology and medicinal chemistry. Due to the huge amount of computational time that is still required, docking is often the last step in a virtual screening approach. Such screenings are set as workflows spanned over many steps, each aiming at different filtering task. These workflows can be automatized in large parts using python based toolkits except for docking using the docking software GOLD. However, within an automated virtual screening workflow it is not feasible to use the GUI in between every step to change the GOLD configuration file. Thus, a python module called PyGOLD was developed, to parse, edit and write the GOLD configuration file and to automate docking based virtual screening workflows. The latest version of PyGOLD, its documentation and example scripts are available at: http://www.ccb.tu-dortmund.de/koch or http://www.agkoch.de. PyGOLD is implemented in Python and can be imported as a standard python module without any further dependencies. oliver.koch@agkoch.de, oliver.koch@tu-dortmund.de. Supplementary data are available at Bioinformatics online. © The Author (2017). Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  15. Creating an open access cal/val repository via the LACO-Wiki online validation platform

    NASA Astrophysics Data System (ADS)

    Perger, Christoph; See, Linda; Dresel, Christopher; Weichselbaum, Juergen; Fritz, Steffen

    2017-04-01

    There is a major gap in the amount of in-situ data available on land cover and land use, either as field-based ground truth information or from image interpretation, both of which are used for the calibration and validation (cal/val) of products derived from Earth Observation. Although map producers generally publish their confusion matrices and the accuracy measures associated with their land cover and land use products, the cal/val data (also referred to as reference data) are rarely shared in an open manner. Although there have been efforts in compiling existing reference datasets and making them openly available, e.g. through the GOFC/GOLD (Global Observation for Forest Cover and Land Dynamics) portal or the European Commission's Copernicus Reference Data Access (CORDA), this represents a tiny fraction of the reference data collected and stored locally around the world. Moreover, the validation of land cover and land use maps is usually undertaken with tools and procedures specific to a particular institute or organization due to the lack of standardized validation procedures; thus, there are currently no incentives to share the reference data more broadly with the land cover and land use community. In an effort to provide a set of standardized, online validation tools and to build an open repository of cal/val data, the LACO-Wiki online validation portal has been developed, which will be presented in this paper. The portal contains transparent, documented and reproducible validation procedures that can be applied to local as well as global products. LACO-Wiki was developed through a user consultation process that resulted in a 4-step wizard-based workflow, which supports the user from uploading the map product for validation, through to the sampling process and the validation of these samples, until the results are processed and a final report is created that includes a range of commonly reported accuracy measures. One of the design goals of LACO-Wiki has been to simplify the workflows as much as possible so that the tool can be used both professionally and in an educational or non-expert context. By using the tool for validation, the user agrees to share their validation samples and therefore contribute to an open access cal/val repository. Interest in the use of LACO-Wiki for validation of national land cover or related products has already been expressed, e.g. by national stakeholders under the umbrella of the European Environment Agency (EEA), and for global products by GOFC/GOLD and the Group on Earth Observation (GEO). Thus, LACO-Wiki has the potential to become the focal point around which an international land cover validation community could be built, and could significantly advance the state-of-the-art in land cover cal/val, particularly given recent developments in opening up of the Landsat archive and the open availability of Sentinel imagery. The platform will also offer open access to crowdsourced in-situ data, for example, from the recently developed LACO-Wiki mobile smartphone app, which can be used to collect additional validation information in the field, as well as to validation data collected via its partner platform, Geo-Wiki, where an already established community of citizen scientists collect land cover and land use data for different research applications.

  16. Blue Star/Gold Star Flag Act of 2010

    THOMAS, 111th Congress

    Rep. Boccieri, John A. [D-OH-16

    2009-05-21

    Senate - 05/20/2010 Received in the Senate and Read twice and referred to the Committee on Banking, Housing, and Urban Affairs. (All Actions) Tracker: This bill has the status Passed HouseHere are the steps for Status of Legislation:

  17. Diagnosis of Acute Q Fever by Detection of Coxiella burnetii DNA using Real-Time PCR, Employing a Commercial Genesig Easy Kit

    PubMed Central

    Pradeep, Jothimani; Ambroise, Stanley; Gunasekaran, Dhandapany

    2017-01-01

    Introduction Query (Q) fever is an important zoonosis and a cause of concern for humans, due to the potential bioterrorism threat posed by the causative agent, Coxiella burnetii. Because of the danger of contracting the illness, isolation attempts are seldom made. Serological and molecular diagnostic tests are the main option. Aim To study the prevalence of acute Q fever in Puducherry and surrounding districts of Tamil Nadu, India, employing a new commercial Real-Time Polymerase Chain Reaction (RT-PCR) kit and confirming it by the gold standard Immunofluorescence Assay (IFA). Materials and Methods Acute phase blood samples from 72 consecutive febrile patients and 24 healthy individuals were included in this prospective study. DNA was extracted from the buffy coats and preserved at -80°C. Detection of C. burnetii was carried out employing a commercial Real-Time PCR kit. Serum samples were tested for IgM (Phase I+II) and IgG (Phase I+II) by QM-120 and QG-120, Coxiella burnetii IFA Fuller Laboratories, California, USA. Sensitivity, Specificity, Positive Predictive Value (PPV) and Negative Predictive Value (NPV) were calculated keeping IFA as the reference. Results Presumptive diagnosis of acute Q fever was made in two febrile patients by the Genesig Easy kit (2.78%). In addition to these two PCR positive cases, one more patient was positive for both Phase II IgM and Phase II IgG antibodies by the gold standard IFA. All 24 healthy controls were negative for Q fever by both PCR and IFA. The sensitivity, specificity, NPV and PPV for Genesig Easy kit PCR were: 66.67%, 100%, 100% and 98.57 % respectively against IFA as the reference. Conclusion The true prevalence of Q fever in India and other developing countries is poorly understood, owing to the difficulties in the diagnosis of this infection. Since molecular diagnostic tests have good specificity and are mandated for confirmation of single acute samples, validation of commercial Q fever PCR kits is the need of the hour. Genesig Easy kit in our hands was found to be reliable with the moderate sensitivity and high specificity. Performing both PCR (with acute specimens) and IFA (with paired sera) would be ideal for Q fever diagnosis. PMID:29207703

  18. 3D-Modeling of deformed halite hopper crystals: Object based image analysis and support vector machine, a first evaluation

    NASA Astrophysics Data System (ADS)

    Leitner, Christoph; Hofmann, Peter; Marschallinger, Robert

    2014-05-01

    Halite hopper crystals are thought to develop by displacive growth in unconsolidated mud (Gornitz & Schreiber, 1984). The Alpine Haselgebirge, but also e.g. the salt deposits of the Rhine graben (mined at the beginning of the 20th century), comprise hopper crystals with shapes of cuboids, parallelepipeds and rhombohedrons (Görgey, 1912). Obviously, they deformed under oriented stress, which had been tried to reconstruct with respect to the sedimentary layering (Leitner et al., 2013). In the present work, deformed halite hopper crystals embedded in mudrock were automated reconstructed. Object based image analysis (OBIA) has been used successfully in remote sensing for 2D images before. The present study represents the first time that the method was used for reconstruction of three dimensional geological objects. First, manually a reference (gold standard) was created by redrawing contours of the halite crystals on each HRXCT scanning slice. Then, for OBIA, the computer program eCognition was used. For the automated reconstruction a rule set was developed. Thereby, the strength of OBIA was to recognize all objects similar to halite hopper crystals and in particular to eliminate cracks. In a second step, all the objects unsuitable for a structural deformation analysis were dismissed using a support vector machine (SVM) (clusters, polyhalite-coated crystals and spherical halites) The SVM simultaneously drastically reduced the number of halites. From 184 OBIA-objects 67 well shaped remained, which comes close to the number of pre-selected 52 objects. To assess the accuracy of the automated reconstruction, the result before and after SVM was compared to the reference, i.e. the gold standard. State-of the art per-scene statistics were extended to a per-object statistics. Görgey R (1912) Zur Kenntnis der Kalisalzlager von Wittelsheim im Ober-Elsaß. Tschermaks Mineral Petrogr Mitt 31:339-468 Gornitz VM, Schreiber BC (1981) Displacive halite hoppers from the dead sea: Some implications for ancient evaporite deposits. J of Sediment Petrol 51:787-794. doi: 10.1306/212F7DAB-2B24-11D7-8648000102C1865D Leitner C, Neubauer F, Marschallinger R, Genser J, Bernroider M (2013) Origin of deformed halite hopper crystals, pseudomorphic anhydrite cubes and polyhalite in Alpine evaporates (Austria, Germany). Int J Earth Sc 102, pp 813-829, doi: 10.1007/s00531-012-0836-6

  19. Performance of serological tests for syphilis in sexually transmitted diseases clinics in Guangxi Autonomous Region, China: implications for syphilis surveillance and control.

    PubMed

    Yin, Yue-Ping; Wei, Wan-Hui; Wang, Hong-Chun; Zhu, Bang-Yong; Yu, Yan-Hua; Chen, Xiang-Sheng; Peeling, Rosanna W; Cohen, Myron S

    2009-03-01

    China is experiencing a growing syphilis epidemic. Individuals are currently screened and cases are confirmed using traditional serological testing methods. A total of 11 558 serum specimens from patients at 14 sexually transmitted diseases (STD) clinics at provincial, prefecture and county levels in Guangxi Autonomous Region were tested at local clinics using the toluidine red unheated serum test (TRUST) and the SD Bioline Syphilis 3.0 Treponema Pallidum (SD-TP) test and then transported to the National STD Reference Laboratory for TRUST and confirmatory Treponema pallidum particle assay (TPPA) testing. In local clinics, 13.2% of specimens were TRUST positive and 12.8% were TRUST and SD-TP positive. At the Reference Laboratory, 15.4% of specimens were TRUST positive and 11.8% were TRUST and TPPA positive. Local clinics showed a significantly higher prevalence of active syphilis compared with results from the Reference Laboratory (12.8 v. 11.8%, chi(2) = 4.59, P = 0.03). The local TRUST tests had consistent results with Reference Laboratory tests qualitatively among 96.2% of the specimens and quantitatively among 95.5% of the specimens. The algorithm of TRUST screening and then SD-TP confirmation among positive TRUST specimens at local STD clinics had 96.6% sensitivity and 99.3% specificity in diagnosing active syphilis compared with the 'gold standard' based on TRUST and TPPA positivity at the Reference Laboratory (positive predictive value 95.1% and negative predictive value 99.5%). The TRUST screening and SD-TP confirmation in combination can be used at local STD clinics for the efficient diagnosis of serologically active syphilis. However, continuing capacity building and quality assurance remain critical in ensuring the quality of syphilis diagnosis at local clinics.

  20. Plan selection strategy for rectum cancer patients: An interobserver study to assess clinical feasibility.

    PubMed

    de Jong, Rianne; Lutkenhaus, Lotte; van Wieringen, Niek; Visser, Jorrit; Wiersma, Jan; Crama, Koen; Geijsen, Debby; Bel, Arjan

    2016-08-01

    In radiotherapy for rectum cancer, the target volume is highly deformable. An adaptive plan selection strategy can mitigate the effect of these variations. The purpose of this study was to evaluate the feasibility of an adaptive strategy by assessing the interobserver variation in CBCT-based plan selection. Eleven patients with rectum cancer, treated with a non-adaptive strategy, were selected. Five CBCT scans were available per patient. To simulate the plan selection strategy, per patient three PTVs were created by varying the anterior upper mesorectum margin. For each CBCT scan, twenty observers selected the smallest PTV that encompassed the target volume. After this initial baseline measurement, the gold standard was determined during a consensus meeting, followed by a second measurement one month later. Differences between both measurements were assessed using the Wilcoxon signed-rank test. In the baseline measurement, the concordance with the gold standard was 69% (range: 60-82%), which improved to 75% (range: 60-87%) in the second measurement (p=0.01). For the second measurement, 10% of plan selections were smaller than the gold standard. With a plan selection consistency between observers of 75%, a plan selection strategy for rectum cancer patients is feasible. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  1. An audit of the laboratory service provided to the Health Service Executive Orthodontic Department, St James Hospital, Dublin.

    PubMed

    Al-Awadhi, E A; Wolstencroft, S J; Blake, M

    2006-01-01

    To evaluate the service purchased from contracted orthodontic laboratories used by HSE (SWA) regional orthodontic unit, St. James's Hospital, Dublin and identify deficiencies in the current service. A data collection questionnaire was designed and distributed to the departmental orthodontists for a period of three months (October-December 2004). Gold standards, drawn up based on the authors' ideal requirements and published guidelines, were supplied to grade the work returned. During the study period 363 items of laboratory work were requested. 20% of the laboratory work arrived late and most of the delayed work was delayed for more than 24 hours. Most laboratory delays occurred with functional appliances, retainers and study models. Prior to fit, 20% of the appliances required adjustments for more than 30 seconds. 65% of laboratory work returned to the department met all of the gold standards. 10% of appliances were considered unsatisfactory. Functional appliances were most often ill fitting accounting for almost half of the unsatisfactory laboratory work. The majority of the laboratory work returned to the department met our gold standards and arrived on time. Forty six percent of the appliances required adjustments. Functional appliances required the most adjustments; one in five of all functional appliances ordered were considered unsatisfactory.

  2. Testing Pneumonia Vaccines in the Elderly: Determining a Case Definition for Pneumococcal Pneumonia in the Absence of a Gold Standard.

    PubMed

    Jokinen, Jukka; Snellman, Marja; Palmu, Arto A; Saukkoriipi, Annika; Verlant, Vincent; Pascal, Thierry; Devaster, Jeanne-Marie; Hausdorff, William P; Kilpi, Terhi M

    2018-06-01

    Clinical assessments of vaccines to prevent pneumococcal community-acquired pneumonia (CAP) require sensitive and specific case definitions, but there is no gold standard diagnostic test. To develop a new case definition suitable for vaccine efficacy studies, we applied latent class analysis (LCA) to the results from 7 diagnostic tests for pneumococcal etiology on clinical specimens from 323 elderly persons with radiologically confirmed pneumonia enrolled in the Finnish Community-Acquired Pneumonia Epidemiology study during 2005-2007. Compared with the conventional use of LCA, which is mainly to determine sensitivities and specificities of different tests, we instead used LCA as an appropriate instrument to predict the probability of pneumococcal etiology for each CAP case based on individual test profiles, and we used the predictions to minimize the sample size that would be needed for a vaccine efficacy trial. When compared with the conventional laboratory criteria of encapsulated pneumococci in culture, in blood culture or high-quality sputum culture, or urine antigen positivity, our optimized case definition for pneumococcal CAP resulted in a trial sample size that was almost 20,000 subjects smaller. We believe that the novel application of LCA detailed here to determine a case definition for pneumococcal CAP could also be similarly applied to other diseases without a gold standard.

  3. Development of a mobile application for oral cancer screening.

    PubMed

    Gomes, Mayra Sousa; Bonan, Paulo Rogério Ferreti; Ferreira, Vitor Yuri Nicolau; de Lucena Pereira, Laudenice; Correia, Ricardo João Cruz; da Silva Teixeira, Hélder Bruno; Pereira, Daniel Cláudio; Bonan, Paulo

    2017-01-01

    To develop a mobile application (app) for oral cancer screening. The app was developed using Android system version 4.4.2, with JAVA language. Information concerning sociodemographic data and risk factors for oral cancer development, e.g., tobacco and alcohol use, sun exposure and other contributing factors, such as unprotected oral sex, oral pain and denture use, were included. We surveyed a population at high risk for oral cancer development and then evaluated the sensitivity/specificity/accuracy and predictive values of clinical oral diagnosis between two blinded trained examiners, who used movies and data from the app, and in loco oral examination as gold-standard. A total of 55 individuals at high risk for oral cancer development were surveyed. Of these, 31% presented homogeneous/heterogeneous white lesions with potential of malignancy. The clinical diagnoses performed by the two examiners using videos were found to have sensitivity of 82%-100% (average 91%), specificity of 81%-100% (average 90.5%), and accuracy of 87.27%-95.54% (average 90.90%), as compared with the gold-standard. The Kappa agreement value between the gold-standard and the examiner with the best agreement was 0.597. Mobile apps including videos and data collection interfaces could be an interesting alternative in oral cancer research development.

  4. Comparison of micro-computerized tomography and cone-beam computerized tomography in the detection of accessory canals in primary molars.

    PubMed

    Acar, Buket; Kamburoğlu, Kıvanç; Tatar, İlkan; Arıkan, Volkan; Çelik, Hakan Hamdi; Yüksel, Selcen; Özen, Tuncer

    2015-12-01

    This study was performed to compare the accuracy of micro-computed tomography (CT) and cone-beam computed tomography (CBCT) in detecting accessory canals in primary molars. Forty-one extracted human primary first and second molars were embedded in wax blocks and scanned using micro-CT and CBCT. After the images were taken, the samples were processed using a clearing technique and examined under a stereomicroscope in order to establish the gold standard for this study. The specimens were classified into three groups: maxillary molars, mandibular molars with three canals, and mandibular molars with four canals. Differences between the gold standard and the observations made using the imaging methods were calculated using Spearman's rho correlation coefficient test. The presence of accessory canals in micro-CT images of maxillary and mandibular root canals showed a statistically significant correlation with the stereomicroscopic images used as a gold standard. No statistically significant correlation was found between the CBCT findings and the stereomicroscopic images. Although micro-CT is not suitable for clinical use, it provides more detailed information about minor anatomical structures. However, CBCT is convenient for clinical use but may not be capable of adequately analyzing the internal anatomy of primary teeth.

  5. Gold(III) complexes with hydroxyquinoline, aminoquinoline and quinoline ligands: Synthesis, cytotoxicity, DNA and protein binding studies.

    PubMed

    Martín-Santos, Cecilia; Michelucci, Elena; Marzo, Tiziano; Messori, Luigi; Szumlas, Piotr; Bednarski, Patrick J; Mas-Ballesté, Rubén; Navarro-Ranninger, Carmen; Cabrera, Silvia; Alemán, José

    2015-12-01

    In this article, we report on the synthesis and the chemical and biological characterization of novel gold(III) complexes based on hydroxyl- or amino-quinoline ligands that are evaluated as prospective anticancer agents. To gain further insight into their reactivity and possible mode of action, their interactions with model proteins and standard nucleic acid molecules were investigated. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Sepsis Definitions: The Search for Gold and What CMS Got Wrong.

    PubMed

    Kalantari, Annahieta; Mallemat, Haney; Weingart, Scott D

    2017-08-01

    On October 1, 2015, the United States Centers for Medicare and Medicaid Services (CMS) issued a core measure addressing the care of septic patients. These core measures are controversial among healthcare providers. This article will address that there is no gold standard definition for sepsis, severe sepsis or septic shock and the CMS-assigned definitions for severe sepsis and septic shock are premature and inconsistent with evidence-based definitions.

  7. Factors Influencing Performance of Internet-Based Biosurveillance Systems Used in Epidemic Intelligence for Early Detection of Infectious Diseases Outbreaks

    PubMed Central

    Barboza, Philippe; Vaillant, Laetitia; Le Strat, Yann; Hartley, David M.; Nelson, Noele P.; Mawudeku, Abla; Madoff, Lawrence C.; Linge, Jens P.; Collier, Nigel; Brownstein, John S.; Astagneau, Pascal

    2014-01-01

    Background Internet-based biosurveillance systems have been developed to detect health threats using information available on the Internet, but system performance has not been assessed relative to end-user needs and perspectives. Method and Findings Infectious disease events from the French Institute for Public Health Surveillance (InVS) weekly international epidemiological bulletin published in 2010 were used to construct the gold-standard official dataset. Data from six biosurveillance systems were used to detect raw signals (infectious disease events from informal Internet sources): Argus, BioCaster, GPHIN, HealthMap, MedISys and ProMED-mail. Crude detection rates (C-DR), crude sensitivity rates (C-Se) and intrinsic sensitivity rates (I-Se) were calculated from multivariable regressions to evaluate the systems’ performance (events detected compared to the gold-standard) 472 raw signals (Internet disease reports) related to the 86 events included in the gold-standard data set were retrieved from the six systems. 84 events were detected before their publication in the gold-standard. The type of sources utilised by the systems varied significantly (p<0001). I-Se varied significantly from 43% to 71% (p = 0001) whereas other indicators were similar (C-DR: p = 020; C-Se, p = 013). I-Se was significantly associated with individual systems, types of system, languages, regions of occurrence, and types of infectious disease. Conversely, no statistical difference of C-DR was observed after adjustment for other variables. Conclusion Although differences could result from a biosurveillance system's conceptual design, findings suggest that the combined expertise amongst systems enhances early detection performance for detection of infectious diseases. While all systems showed similar early detection performance, systems including human moderation were found to have a 53% higher I-Se (p = 00001) after adjustment for other variables. Overall, the use of moderation, sources, languages, regions of occurrence, and types of cases were found to influence system performance. PMID:24599062

  8. Factors influencing performance of internet-based biosurveillance systems used in epidemic intelligence for early detection of infectious diseases outbreaks.

    PubMed

    Barboza, Philippe; Vaillant, Laetitia; Le Strat, Yann; Hartley, David M; Nelson, Noele P; Mawudeku, Abla; Madoff, Lawrence C; Linge, Jens P; Collier, Nigel; Brownstein, John S; Astagneau, Pascal

    2014-01-01

    Internet-based biosurveillance systems have been developed to detect health threats using information available on the Internet, but system performance has not been assessed relative to end-user needs and perspectives. Infectious disease events from the French Institute for Public Health Surveillance (InVS) weekly international epidemiological bulletin published in 2010 were used to construct the gold-standard official dataset. Data from six biosurveillance systems were used to detect raw signals (infectious disease events from informal Internet sources): Argus, BioCaster, GPHIN, HealthMap, MedISys and ProMED-mail. Crude detection rates (C-DR), crude sensitivity rates (C-Se) and intrinsic sensitivity rates (I-Se) were calculated from multivariable regressions to evaluate the systems' performance (events detected compared to the gold-standard) 472 raw signals (Internet disease reports) related to the 86 events included in the gold-standard data set were retrieved from the six systems. 84 events were detected before their publication in the gold-standard. The type of sources utilised by the systems varied significantly (p<0001). I-Se varied significantly from 43% to 71% (p=0001) whereas other indicators were similar (C-DR: p=020; C-Se, p=013). I-Se was significantly associated with individual systems, types of system, languages, regions of occurrence, and types of infectious disease. Conversely, no statistical difference of C-DR was observed after adjustment for other variables. Although differences could result from a biosurveillance system's conceptual design, findings suggest that the combined expertise amongst systems enhances early detection performance for detection of infectious diseases. While all systems showed similar early detection performance, systems including human moderation were found to have a 53% higher I-Se (p=00001) after adjustment for other variables. Overall, the use of moderation, sources, languages, regions of occurrence, and types of cases were found to influence system performance.

  9. Accurate GM atrophy quantification in MS using lesion-filling with co-registered 2D lesion masks☆

    PubMed Central

    Popescu, V.; Ran, N.C.G.; Barkhof, F.; Chard, D.T.; Wheeler-Kingshott, C.A.; Vrenken, H.

    2014-01-01

    Background In multiple sclerosis (MS), brain atrophy quantification is affected by white matter lesions. LEAP and FSL-lesion_filling, replace lesion voxels with white matter intensities; however, they require precise lesion identification on 3DT1-images. Aim To determine whether 2DT2 lesion masks co-registered to 3DT1 images, yield grey and white matter volumes comparable to precise lesion masks. Methods 2DT2 lesion masks were linearly co-registered to 20 3DT1-images of MS patients, with nearest-neighbor (NNI), and tri-linear interpolation. As gold-standard, lesion masks were manually outlined on 3DT1-images. LEAP and FSL-lesion_filling were applied with each lesion mask. Grey (GM) and white matter (WM) volumes were quantified with FSL-FAST, and deep gray matter (DGM) volumes using FSL-FIRST. Volumes were compared between lesion mask types using paired Wilcoxon tests. Results Lesion-filling with gold-standard lesion masks compared to native images reduced GM overestimation by 1.93 mL (p < .001) for LEAP, and 1.21 mL (p = .002) for FSL-lesion_filling. Similar effects were achieved with NNI lesion masks from 2DT2. Global WM underestimation was not significantly influenced. GM and WM volumes from NNI, did not differ significantly from gold-standard. GM segmentation differed between lesion masks in the lesion area, and also elsewhere. Using the gold-standard, FSL-FAST quantified as GM on average 0.4% of the lesion area with LEAP and 24.5% with FSL-lesion_filling. Lesion-filling did not influence DGM volumes from FSL-FIRST. Discussion These results demonstrate that for global GM volumetry, precise lesion masks on 3DT1 images can be replaced by co-registered 2DT2 lesion masks. This makes lesion-filling a feasible method for GM atrophy measurements in MS. PMID:24567908

  10. Detection of Echinococcus multilocularis by MC-PCR: evaluation of diagnostic sensitivity and specificity without gold standard.

    PubMed

    Wahlström, Helene; Comin, Arianna; Isaksson, Mats; Deplazes, Peter

    2016-01-01

    A semi-automated magnetic capture probe-based DNA extraction and real-time PCR method (MC-PCR), allowing for a more efficient large-scale surveillance of Echinococcus multilocularis occurrence, has been developed. The test sensitivity has previously been evaluated using the sedimentation and counting technique (SCT) as a gold standard. However, as the sensitivity of the SCT is not 1, test characteristics of the MC-PCR was also evaluated using latent class analysis, a methodology not requiring a gold standard. Test results, MC-PCR and SCT, from a previous evaluation of the MC-PCR using 177 foxes shot in the spring (n=108) and autumn 2012 (n=69) in high prevalence areas in Switzerland were used. Latent class analysis was used to estimate the test characteristics of the MC-PCR. Although it is not the primary aim of this study, estimates of the test characteristics of the SCT were also obtained. This study showed that the sensitivity of the MC-PCR was 0.88 [95% posterior credible interval (PCI) 0.80-0.93], which was not significantly different than the SCT, 0.83 (95% PCI 0.76-0.88), which is currently considered as the gold standard. The specificity of both tests was high, 0.98 (95% PCI 0.94-0.99) for the MC-PCR and 0.99 (95% PCI 0.99-1) for the SCT. In a previous study, using fox scats from a low prevalence area, the specificity of the MC-PCR was higher, 0.999% (95% PCI 0.997-1). One reason for the lower estimate of the specificity in this study could be that the MC-PCR detects DNA from infected but non-infectious rodents eaten by foxes. When using MC-PCR in low prevalence areas or areas free from the parasite, a positive result in the MC-PCR should be regarded as a true positive. The sensitivity of the MC-PCR (0.88) was comparable to the sensitivity of SCT (0.83).

  11. Evaluation of dental therapists undertaking dental examinations in a school setting in Scotland.

    PubMed

    O'Keefe, Emma J; McMahon, Alex D; Jones, Colwyn M; Curnow, Morag M; Macpherson, Lorna M D

    2016-12-01

    To measure agreement between dental therapists and the Scottish gold-standard dentist undertaking National Dental Inspection Programme (NDIP) examinations. A study of interexaminer agreement between 19 dental therapists and the national gold-standard dentist was carried out. Pre-calibration training used the caries diagnostic criteria and examination techniques agreed by the British Association for the Study of Community Dentistry (BASCD). Twenty-three 5-year-old children (Primary 1) and 17 11-year-old children (Primary 7) children were examined. Agreement was assessed using kappa statistics on d 3 mft and D 3 MFT for P1 and P7 children, sensitivity and specificity values, and kappa statistics on d 3 t/D 3 T and ft/FT. Calibration data on P1 and P7 children from 2009-2012 involving dentists as examiners were used for comparison. Economic evaluation was undertaken using a cost minimization analysis approach. The mean kappa score was 0.84 (SD 0.07) ranging from 0.69 to 0.94. All dental therapists scored good or very good agreement with the gold-standard dentist. This compares with historic NDIP calibration data with dentists, against the same gold-standard dentist, where the mean kappa value was 0.68 (SD 0.22) with a range of 0.35-1.00. The mean sensitivity score was 0.98 (SD 0.04) (range 0.88-1.0) and mean specificity score was 0.90 (SD 0.06) (range 0.78-0.96). Health economic analysis estimated that salary costs would be 33.6% lower if dental therapists were substituted for dentists in the year 2013, with an estimated saving of approximately £103 646 per annum on the national budget. We conclude that dental therapists show a high level of interexaminer agreement, and with the appropriate annual training and calibration, they could undertake dental examinations as part of the NDIP programme. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. Cardiac auscultatory recording database: delivering heart sounds through the Internet.

    PubMed Central

    Tuchinda, C.; Thompson, W. R.

    2001-01-01

    The clinical skill of cardiac auscultation, while known to be sensitive, specific, and inexpensive in screening for cardiac disease among children, has recently been shown to be deficient among residents in training. This decline in clinical skill is partly due to the difficulty in teaching auscultation. Standardization, depth, and breadth of experience has been difficult to reproduce for students due to time constraints and the impracticality of examining large numbers of patients with cardiac pathology. We have developed a web-based multimedia platform that delivers complete heart sound recordings from over 800 different patients seen at the Johns Hopkins Outpatient Pediatric Cardiology Clinic. The database represents more than twenty significant cardiac lesions as well as normal and innocent murmurs. Each patient record is complete with a gold standard echo for diagnostic confirmation and a gold standard auscultatory assessment provided by a pediatric cardiology attending. PMID:11825279

  13. Evaluating the quality of a cell counting measurement process via a dilution series experimental design.

    PubMed

    Sarkar, Sumona; Lund, Steven P; Vyzasatya, Ravi; Vanguri, Padmavathy; Elliott, John T; Plant, Anne L; Lin-Gibson, Sheng

    2017-12-01

    Cell counting measurements are critical in the research, development and manufacturing of cell-based products, yet determining cell quantity with accuracy and precision remains a challenge. Validating and evaluating a cell counting measurement process can be difficult because of the lack of appropriate reference material. Here we describe an experimental design and statistical analysis approach to evaluate the quality of a cell counting measurement process in the absence of appropriate reference materials or reference methods. The experimental design is based on a dilution series study with replicate samples and observations as well as measurement process controls. The statistical analysis evaluates the precision and proportionality of the cell counting measurement process and can be used to compare the quality of two or more counting methods. As an illustration of this approach, cell counting measurement processes (automated and manual methods) were compared for a human mesenchymal stromal cell (hMSC) preparation. For the hMSC preparation investigated, results indicated that the automated method performed better than the manual counting methods in terms of precision and proportionality. By conducting well controlled dilution series experimental designs coupled with appropriate statistical analysis, quantitative indicators of repeatability and proportionality can be calculated to provide an assessment of cell counting measurement quality. This approach does not rely on the use of a reference material or comparison to "gold standard" methods known to have limited assurance of accuracy and precision. The approach presented here may help the selection, optimization, and/or validation of a cell counting measurement process. Published by Elsevier Inc.

  14. Hybrid metal grid-polymer-carbon nanotube electrodes for high luminance organic light emitting diodes

    NASA Astrophysics Data System (ADS)

    Sam, F. Laurent M.; Dabera, G. Dinesha M. R.; Lai, Khue T.; Mills, Christopher A.; Rozanski, Lynn J.; Silva, S. Ravi P.

    2014-08-01

    Organic light emitting diodes (OLEDs) incorporating grid transparent conducting electrodes (TCEs) with wide grid line spacing suffer from an inability to transfer charge carriers across the gaps in the grids to promote light emission in these areas. High luminance OLEDs fabricated using a hybrid TCE composed of poly(3,4-ethylenedioxythiophene) poly(styrenesulfonate) (PEDOT:PSS PH1000) or regioregular poly(3-hexylthiophene)-wrapped semiconducting single-walled carbon nanotubes (rrP3HT-SWCNT) in combination with a nanometre thin gold grid are reported here. OLEDs fabricated using the hybrid gold grid/PH1000 TCE have a luminance of 18 000 cd m-2 at 9 V; the same as the reference indium tin oxide (ITO) OLED. The gold grid/rrP3HT-SWCNT OLEDs have a lower luminance of 8260 cd m-2 at 9 V, which is likely due to a rougher rrP3HT-SWCNT surface. These results demonstrate that the hybrid gold grid/PH1000 TCE is a promising replacement for ITO in future plastic electronics applications including OLEDs and organic photovoltaics. For applications where surface roughness is not critical, e.g. electrochromic devices or discharge of static electricity, the gold grid/rrP3HT-SWCNT hybrid TCE can be employed.

  15. Gold Star Fathers Act of 2011

    THOMAS, 112th Congress

    Sen. Wyden, Ron [D-OR

    2011-03-08

    Senate - 05/09/2011 Committee on Homeland Security and Governmental Affairs referred to Subcommittee on Oversight of Government Management, the Federal Workforce, and the District of Columbia. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:

  16. 76 FR 81901 - Approval and Promulgation of Implementation Plans and Designations of Areas for Air Quality...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-29

    ....071 0.082 0.082 1009). Rowan County (NC) 301 West St & Gold Hill Ave. (37-159- 0.084 0.071 0.077 0.077... Environmental protection, Air pollution control, Incorporation by reference, Intergovernmental relations...

  17. Comparison of Some Secondary Body Composition Algorithms

    ERIC Educational Resources Information Center

    Sutton, Robert A.; Miller, Carolyn

    2006-01-01

    Body composition measurements vary greatly in degree of measurement difficulty and accuracy. Hydrostatic weighing, chemical dilution or their equivalents were the accepted "gold" standards for assessing fat mass. Dual Energy X-ray Absorptiometry (DEXA) is fast replacing these techniques as the preferred standard. However, these direct measurement…

  18. Assessment of five different guideline indication criteria for spirometry, including modified GOLD criteria, in order to detect COPD: data from 5,315 subjects in the PLATINO study.

    PubMed

    Luize, Ana P; Menezes, Ana Maria B; Perez-Padilla, Rogelio; Muiño, Adriana; López, Maria Victorina; Valdivia, Gonzalo; Lisboa, Carmem; Montes de Oca, Maria; Tálamo, Carlos; Celli, Bartolomé; Nascimento, Oliver A; Gazzotti, Mariana R; Jardim, José R

    2014-10-30

    Spirometry is the gold standard for diagnosing chronic obstructive pulmonary disease (COPD). Although there are a number of different guideline criteria for deciding who should be selected for spirometric screening, to date it is not known which criteria are the best based on sensitivity and specificity. Firstly, to evaluate the proportion of subjects in the PLATINO Study that would be recommended for spirometry testing according to Global initiative for Obstructive Lung Disease (GOLD)-modified, American College of Chest Physicians (ACCP), National Lung Health Education Program (NLHEP), GOLD and American Thoracic Society/European Respiratory Society (ATS/ERS) criteria. Secondly, we aimed to compare the sensitivity, specificity, and positive predictive and negative predictive values, of these five different criteria. Data from the PLATINO study included information on respiratory symptoms, smoking and previous spirometry testing. The GOLD-modified spirometry indication criteria are based on three positive answers out of five questions: the presence of cough, phlegm in the morning, dyspnoea, age over 40 years and smoking status. Data from 5,315 subjects were reviewed. Fewer people had an indication for spirometry (41.3%) according to the GOLD-modified criteria, and more people had an indication for spirometry (80.4%) by the GOLD and ATS/ERS criteria. A low percentage had previously had spirometry performed: GOLD-modified (14.5%); ACCP (13.2%); NLHEP (12.6%); and GOLD and ATS/ERS (12.3%). The GOLD-modified criteria showed the least sensitivity (54.9) and the highest specificity (61.0) for detecting COPD, whereas GOLD and ATS/ERS criteria showed the highest sensitivity (87.9) and the least specificity (20.8). There is a considerable difference in the indication for spirometry according to the five different guideline criteria. The GOLD-modified criteria recruit less people with the greatest sum of sensitivity and specificity.

  19. Assessment of five different guideline indication criteria for spirometry, including modified GOLD criteria, in order to detect COPD: data from 5,315 subjects in the PLATINO study

    PubMed Central

    Luize, Ana P; Menezes, Ana Maria B; Perez-Padilla, Rogelio; Muiño, Adriana; López, Maria Victorina; Valdivia, Gonzalo; Lisboa, Carmem; Montes de Oca, Maria; Tálamo, Carlos; Celli, Bartolomé; Nascimento, Oliver A; Gazzotti, Mariana R; Jardim, José R

    2014-01-01

    Background: Spirometry is the gold standard for diagnosing chronic obstructive pulmonary disease (COPD). Although there are a number of different guideline criteria for deciding who should be selected for spirometric screening, to date it is not known which criteria are the best based on sensitivity and specificity. Aims: Firstly, to evaluate the proportion of subjects in the PLATINO Study that would be recommended for spirometry testing according to Global initiative for Obstructive Lung Disease (GOLD)-modified, American College of Chest Physicians (ACCP), National Lung Health Education Program (NLHEP), GOLD and American Thoracic Society/European Respiratory Society (ATS/ERS) criteria. Secondly, we aimed to compare the sensitivity, specificity, and positive predictive and negative predictive values, of these five different criteria. Methods: Data from the PLATINO study included information on respiratory symptoms, smoking and previous spirometry testing. The GOLD-modified spirometry indication criteria are based on three positive answers out of five questions: the presence of cough, phlegm in the morning, dyspnoea, age over 40 years and smoking status. Results: Data from 5,315 subjects were reviewed. Fewer people had an indication for spirometry (41.3%) according to the GOLD-modified criteria, and more people had an indication for spirometry (80.4%) by the GOLD and ATS/ERS criteria. A low percentage had previously had spirometry performed: GOLD-modified (14.5%); ACCP (13.2%); NLHEP (12.6%); and GOLD and ATS/ERS (12.3%). The GOLD-modified criteria showed the least sensitivity (54.9) and the highest specificity (61.0) for detecting COPD, whereas GOLD and ATS/ERS criteria showed the highest sensitivity (87.9) and the least specificity (20.8). Conclusion: There is a considerable difference in the indication for spirometry according to the five different guideline criteria. The GOLD-modified criteria recruit less people with the greatest sum of sensitivity and specificity. PMID:25358021

  20. Development and testing of a tool for assessing and resolving medication-related problems in older adults in an ambulatory care setting: the individualized medication assessment and planning (iMAP) tool.

    PubMed

    Crisp, Ginny D; Burkhart, Jena Ivey; Esserman, Denise A; Weinberger, Morris; Roth, Mary T

    2011-12-01

    Medication is one of the most important interventions for improving the health of older adults, yet it has great potential for causing harm. Clinical pharmacists are well positioned to engage in medication assessment and planning. The Individualized Medication Assessment and Planning (iMAP) tool was developed to aid clinical pharmacists in documenting medication-related problems (MRPs) and associated recommendations. The purpose of our study was to assess the reliability and usability of the iMAP tool in classifying MRPs and associated recommendations in older adults in the ambulatory care setting. Three cases, representative of older adults seen in an outpatient setting, were developed. Pilot testing was conducted and a "gold standard" key developed. Eight eligible pharmacists consented to participate in the study. They were instructed to read each case, make an assessment of MRPs, formulate a plan, and document the information using the iMAP tool. Inter-rater reliability was assessed for each case, comparing the pharmacists' identified MRPs and recommendations to the gold standard. Consistency of categorization across reviewers was assessed using the κ statistic or percent agreement. The mean κ across the 8 pharmacists in classifying MRPs compared with the gold standard was 0.74 (range, 0.54-1.00) for case 1 and 0.68 (range, 0.36-1.00) for case 2, indicating substantial agreement. For case 3, percent agreement was 63% (range, 40%-100%). The mean κ across the 8 pharmacists when classifying recommendations compared with the gold standard was 0.87 (range, 0.58-1.00) for case 1 and 0.88 (range, 0.75-1.00) for case 2, indicating almost perfect agreement. For case 3, percent agreement was 68% (range, 40%-100%). Clinical pharmacists found the iMAP tool easy to use. The iMAP tool provides a reliable and standardized approach for clinical pharmacists to use in the ambulatory care setting to classify MRPs and associated recommendations. Future studies will explore the predictive validity of the tool on clinical outcomes such as health care utilization. Copyright © 2011 Elsevier HS Journals, Inc. All rights reserved.

  1. Commonly used reference values underestimate oxygen uptake in healthy, 50-year-old Swedish women.

    PubMed

    Genberg, M; Andrén, B; Lind, L; Hedenström, H; Malinovschi, A

    2018-01-01

    Cardiopulmonary exercise testing (CPET) is the gold standard among clinical exercise tests. It combines a conventional stress test with measurement of oxygen uptake (V O 2 ) and CO 2 production. No validated Swedish reference values exist, and reference values in women are generally understudied. Moreover, the importance of achieved respiratory exchange ratio (RER) and the significance of breathing reserve (BR) at peak exercise in healthy individuals are poorly understood. We compared V O 2 at maximal load (peakV O 2 ) and anaerobic threshold (V O 2@ AT ) in healthy Swedish individuals with commonly used reference values, taking gender into account. Further, we analysed maximal workload and peakV O 2 with regard to peak RER and BR. In all, 181 healthy, 50-year-old individuals (91 women) performed CPET. PeakV O 2 was best predicted using Jones et al. (100·5%), while SHIP reference values underestimated peakV O 2 most: 112·5%. Furthermore, underestimation of peakV O 2 in women was found for all studied reference values (P<0·001) and was largest for SHIP: women had 128% of predicted peakV O 2 , while men had 104%. PeakV O 2 was similar in subjects with peak RER of 1-1·1 and RER > 1·1 (2 328·7 versus 2 176·7 ml min -1 , P = 0·11). Lower BR (≤30%) related to significantly higher peakV O 2 (P<0·001). In conclusion, peakV O 2 was best predicted by Jones. All studied reference values underestimated oxygen uptake in women. No evidence for demanding RER > 1·1 in healthy individuals was found. A lowered BR is probably a normal response to higher workloads in healthy individuals. © 2016 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  2. Gold-on-Polymer-Based Sensing Films for Detection of Organic and Inorganic Analytes in the Air

    NASA Technical Reports Server (NTRS)

    Manatt, Kenneth; Homer, Margie; Ryan, Margaret; Kisor, Adam; Shevade, Abhijit; Jewell, April; Zhou, Hanying

    2008-01-01

    A document discusses gold-on-polymer as one of the novel sensor types developed for part of the sensor development task. Standard polymer-carbon composite sensors used in the JPL Electronic Nose (ENose) have been modified by evaporating 15 nm of metallic gold on the surface. These sensors have been shown to respond to alcohols, aromatics, ammonia, sulfur dioxide, and elemental mercury in the parts-per-million and parts-per-billion concentration ranges in humidified air. The results have shown good sensitivity of these films operating under mild conditions (operating temperatures 23-28 C and regeneration temperature up to 40 C). This unique sensor combines the diversity of polymer sensors for chemical sensing with their response to a wide variety of analytes with the specificity of a gold sensor that shows strong reaction/binding with selected analyte types, such as mercury or sulfur.

  3. Development of active biofilms of quinoa (Chenopodium quinoa W.) starch containing gold nanoparticles and evaluation of antimicrobial activity.

    PubMed

    Pagno, Carlos H; Costa, Tania M H; de Menezes, Eliana W; Benvenutti, Edilson V; Hertz, Plinho F; Matte, Carla R; Tosati, Juliano V; Monteiro, Alcilene R; Rios, Alessandro O; Flôres, Simone H

    2015-04-15

    Active biofilms of quinoa (Chenopodium quinoa, W.) starch were prepared by incorporating gold nanoparticles stabilised by an ionic silsesquioxane that contains the 1,4-diazoniabicyclo[2.2.2]octane chloride group. The biofilms were characterised and their antimicrobial activity was evaluated against Escherichiacoli and Staphylococcusaureus. The presence of gold nanoparticles produces an improvement in the mechanical, optical and morphological properties, maintaining the thermal and barrier properties unchanged when compared to the standard biofilm. The active biofilms exhibited strong antibacterial activity against food-borne pathogens with inhibition percentages of 99% against E. coli and 98% against S. aureus. These quinoa starch biofilms containing gold nanoparticles are very promising to be used as active food packaging for the maintenance of food safety and extension of the shelf life of packaged foods. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. The reverse J-shaped association between serum total 25-hydroxyvitamin D and all-cause mortality: the impact of assay standardization

    USDA-ARS?s Scientific Manuscript database

    The impact of standardizing the originally measured serum total 25-hydroxyvitamin D [25(OH)D] values from Third National Health and Nutrition Examination Survey (NHANES III, 1988-1994) on the association between 25(OH)D and rate of all-cause mortality was evaluated. Values were standardized to gold ...

  5. GCSE and A Level Reform: Are the New Qualifications Returning a "Gold Standard" of Assessment? Election Factsheet

    ERIC Educational Resources Information Center

    Burdett, Newman

    2015-01-01

    This election factsheet highlights the following points: (1) While the GCSE pass rate has increased since its introduction, this doesn't tell us very much about how standards have changed. Evidence from international surveys suggests that education standards have remained stable. Stopping the use of modules and limiting resits is likely to reduce…

  6. Detection of Cryptosporidium oocysts in fresh and frozen cattle faeces: comparison of three methods.

    PubMed

    Brook, E J; Christley, R M; French, N P; Hart, C A

    2008-01-01

    The aim of this study was to compare the performance of three commonly used screening tests for Cryptosporidium oocysts in fresh and frozen cattle faeces. Twenty-nine freshly voided faecal samples were collected from calves from three farms in the northwest of England. Three diagnostic tests for Cryptosporidium were carried out on each sample both before and after freezing - the modified Ziehl-Neelsen (MZN) and auramine phenol (APh) stains and a commercial enzyme immunoassay (EIA) kit, the ProSpecT Cryptosporidium Microplate assay (Remel, Lenexa, KS). Twelve samples were deemed positive by the reference standard (polymerase chain reaction, PCR). There were some discrepancies between the results of the screening tests and the levels of agreement were quantified. The sensitivity and specificity of each method was determined, with PCR as the gold standard. Sensitivity and specificity of the MZN stain was optimized when samples with fewer than two oocyst-like bodies were classified as negative. All three screening methods used were effective in detecting Cryptosporidium infection in both fresh and frozen calf faeces. This study has highlighted the value of determining characteristics of tests used for diagnosis and epidemiological studies.

  7. Cardiorespiratory system monitoring using a developed acoustic sensor.

    PubMed

    Abbasi-Kesbi, Reza; Valipour, Atefeh; Imani, Khadije

    2018-02-01

    This Letter proposes a wireless acoustic sensor for monitoring heartbeat and respiration rate based on phonocardiogram (PCG). The developed sensor comprises a processor, a transceiver which operates at industrial, scientific and medical band and the frequency of 2.54 GHz as well as two capacitor microphones which one for recording the heartbeat and another one for respiration rate. To evaluate the precision of the presented sensor in estimating heartbeat and respiration rate, the sensor is tested on the different volunteers and the obtained results are compared with a gold standard as a reference. The results reveal that root-mean-square error are determined <2.27 beats/min and 0.92 breaths/min for the heartbeat and respiration rate in turn. While the standard deviation of the error is obtained <1.26 and 0.63 for heartbeat and respiration rate, respectively. Also, the sensor estimate sounds of [Formula: see text] to [Formula: see text] obtained PCG signal with sensitivity and specificity 98.1% and 98.3% in turn that make 3% improvement than previous works. The results prove that the sensor can be appropriate candidate for recognising abnormal condition in the cardiorespiratory system.

  8. Gold leaf: From gilding to the fabrication of disposable, wearable and low-cost electrodes.

    PubMed

    Santos, Mauro Sérgio Ferreira; Ameku, Wilson Akira; Gutz, Ivano Gebhardt Rolf; Paixão, Thiago Regis Longo Cesar

    2018-03-01

    Gold is among the most used materials in electrocatalysis. Despite this, this noble metal is still too expensive to be used in the fabrication of low cost and disposable devices. In the present work, gold-leaf sheets, usually employed in decorative crafts and wedding candies, is introduced as an inexpensive source of gold. Planar-disc and nanoband gold electrodes were simply and easily manufactured by combining gold leaf and polyimide tape. The planar disc electrode exhibited electrochemical behavior similar to that of a commercial gold electrode in 0.2molL -1 H 2 SO 4 ; cyclic voltammetry of a 1mmolL -1 solution of potassium ferricyanide (K 3 [Fe(CN) 6 ]) in 0.2molL -1 KNO 3 , using this novel electrode, displayed an 80mV difference between the oxidation and reduction peak potentials. The electrode also delivers promising prospects for the development of wearable devices. When submitted to severe mechanical deformation, this electrode exhibited neither loss of electrical contact nor significant variation in electrode response, even after fifteen bending and/or folding cycles. The thickness of the gold-leaf sheet facilitates the production of nanoband electrodes with behavior similar to that of ultramicroelectrodes. The electrode surface is easily renewed by cutting a thin slice off its end with a razor blade; this process led to limiting currents that were reproducible, presenting a relative standard deviation (RSD) of 3.8% (n = 5). Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Flame Atomic Absorption Spectrometric Determination of Gold After Solid-Phase Extraction of Its 2-Aminobenzothiazole Complex on Diaion SP-207.

    PubMed

    Unsal, Yunus Emre; Tuzen, Mustafa; Soylak, Mustafa

    2016-01-01

    An SPE of Au (III) on a 2-aminobenzothiazole-coated Diaion SP 207-column system has been developed. The parameters, including pH of solution, amount of 2-aminobenzothiazole, eluent type, sample volume, and flow rates, were examined. The effects of alkali, alkali earth, and some metals were also studied. The recovery values at optimal conditions and detection limits for Au (III) were found as >95% and 3.8 μg L(-1), respectively. The factor of preconcentration was 250. The RSD value was <5%. The capacity of adsorption for the resin was 10.4 mg g(-1). The accuracy of the method was evaluated by the use of CDN-GS-3D gold-certified reference material. The proposed procedure for the determination of gold was applied to water, mine, soil, and anodic slime samples.

  10. Nanomaterial strategies for immunodetection

    NASA Astrophysics Data System (ADS)

    Porter, M. D.; Granger, M. C.; Siperko, L. M.; Lipert, R. J.

    2011-06-01

    Metallic nanoparticles are playing increasingly important roles in biodiagnostic platforms. This emergence reflects the need to detect disease indicating entities at increasingly lower levels in human and veterinary diagnostics, homeland security, and food and water safety. To establish this perspective, this paper overviews our recent work using surface enhanced Raman scattering for detection of proteins, viruses, and microorganisms in heterogeneous immunoassays. It describes the assay platform, which is comprised of an antibody-modified capture substrate and gold nanoparticle-based label. The latter draws on the ability to reproducibly construct gold nanoparticles modified with a monolayer of an intrinsically strong Raman scatterer that is then coated with a layer of antibodies. This construct, referred to as an extrinsic Raman label, takes advantage of the signal enhancement of scatterers when coated on nanometer-sized gold particles and the antigenic binding specificity of the immobilized antibody layer. Challenges related to nonspecific adsorption, particle stability, and measurement reproducibility are also briefly examined.

  11. XANES and EXAFS study of Au-substituted YBa2Cu3O(7-delta)

    NASA Technical Reports Server (NTRS)

    Ruckman, Mark W.; Hepp, Aloysius F.

    1990-01-01

    The near-edge structure (XANES) of the Au L3 and Cu K edges of YBa2Au(0.3)Cu(2.7)O(7-delta) was studied. X ray diffraction suggests that Au goes on the Cu(1) site and XANES shows that this has little effect on the oxidation state of the remaining copper. The gold L3 edge develops a white line feature whose position lies between that of trivalent gold oxide (Au2O3) and monovalent potassium gold cyanide (KAu(CN)2) and whose intensity relative to the edge step is smaller than in the two reference compounds. The L3 EXAFS for Au in the superconductor resembles that of Au2O3. However, differences in the envelope of the Fourier filtered component for the first shell suggest that the local structure of the Au in the superconductor is not equivalent to Au2O3.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Murph, S.

    This study describes a simple two-step approach to coat gold nanorods with a silica/titania shell. Gold nanorods with an aspect ratio of 2.5 (L = 48 {+-} 2 and d = 19 {+-} 1) are synthesized by a silver-seed mediated growth approach according to our previously reported procedure (Hunyadi Murph ACS Symposium Series, Volume 1064, Chapter 8, 2011, 127-163 and reference herein). Gold nanorods are grown on pre-formed gold nano-seeds in the presence of surfactant, cetyltrimethylammonium bromide (CTAB), and a small amount of silver ions. A bifunctional linker molecule which has a thiol group at one end and a silanemore » group at the other is used to derivatize gold nanorods. The silane group is subsequently reacted with both sodium silicate and titanium isopropoxide to a silica/titania shell around the gold nanorods. By fine tuning the reaction conditions, the silica/titania shell thickness can be controlled from {approx}5 to {approx}40nm. The resulting nanomaterials are stable, amenable to scale up and can be isolated without core aggregation or decomposition. These new materials have been characterized by scanning electron microscopy, energy dispersive X-ray analysis, UV-Vis spectroscopy and dynamic light scattering analysis. Photocatalytic activity of Au-silica/titania nanomaterials under visible and UV illumination is measured via degradation of a model dye, methyl orange (MO) under visible and UV illumination. The results indicate a 3 fold improvement in the photocatalytic decomposition rate of MO under visible illumination vs. UV illumination.« less

  13. Status of pre-processing of waste electrical and electronic equipment in Germany and its influence on the recovery of gold.

    PubMed

    Chancerel, Perrine; Bolland, Til; Rotter, Vera Susanne

    2011-03-01

    Waste electrical and electronic equipment (WEEE) contains gold in low but from an environmental and economic point of view relevant concentration. After collection, WEEE is pre-processed in order to generate appropriate material fractions that are sent to the subsequent end-processing stages (recovery, reuse or disposal). The goal of this research is to quantify the overall recovery rates of pre-processing technologies used in Germany for the reference year 2007. To achieve this goal, facilities operating in Germany were listed and classified according to the technology they apply. Information on their processing capacity was gathered by evaluating statistical databases. Based on a literature review of experimental results for gold recovery rates of different pre-processing technologies, the German overall recovery rate of gold at the pre-processing level was quantified depending on the characteristics of the treated WEEE. The results reveal that - depending on the equipment groups - pre-processing recovery rates of gold of 29 to 61% are achieved in Germany. Some practical recommendations to reduce the losses during pre-processing could be formulated. Defining mass-based recovery targets in the legislation does not set incentives to recover trace elements. Instead, the priorities for recycling could be defined based on other parameters like the environmental impacts of the materials. The implementation of measures to reduce the gold losses would also improve the recovery of several other non-ferrous metals like tin, nickel, and palladium.

  14. Interparticle coupling effect of silver-gold heterodimer to enhance light harvesting in ultrathin perovskite solar cell

    NASA Astrophysics Data System (ADS)

    Hu, Zhaosheng; Ma, Tingli; Hayase, Shuzi

    2018-01-01

    Thin perovskite solar cells are under intensive interest since they reduce the amount of absorber layer, especially toxic lead in methylammonium lead iodide (MAPbI3) devices and have wide application in semitransparent and tandem solar cells. However, due to the decrease of the layer thickness, thin perovskite devices with weak light-harvesting have poor performance. Moreover, the performance of plasmonic thin perovskite devices by incorporating noncoupling metal NPs cannot give comparable performance with normal devices. In this perspective, we discuss the implication of employing random silver-gold heterodimers in MAPbI3 solar cells with the aim of establishing some guidelines for the efficient ultrathin perovskite solar cells. This method induces an extraordinarily high light-harvesting for ultrathin perovskite film. And the underlying physical mechanism behind the enhanced absorption is deeply investigated by plasmon hybridization, dipolar-dipolar coupling method and FDTD simulation. We notice that perovskite embedded silver-gold heterodimer overcomes the vanished antibonding plasmon resononse (σ * ) in nonjunction area of gold/silver homodimer. A 150-nm perovskite film with embedded random silver-gold heterodimers with 80 nm size and 25 nm gap distance processes 28.15% absorption enhancement compared to the reference film, which is higher than the reported 10% for gold homodimers. And we also predict a realistic solution-processed, easy, and low-cost fabrication method, which provide a means to realize highly efficient ultrathin perovskite solar cell including other absorber-based photovoltaics.

  15. A Single-Block TRL Test Fixture for the Cryogenic Characterization of Planar Microwave Components

    NASA Technical Reports Server (NTRS)

    Mejia, M.; Creason, A. S.; Toncich, S. S.; Ebihara, B. T.; Miranda, F. A.

    1996-01-01

    The High-Temperature-Superconductivity (HTS) group of the RF Technology Branch, Space Electronics Division, is actively involved in the fabrication and cryogenic characterization of planar microwave components for space applications. This process requires fast, reliable, and accurate measurement techniques not readily available. A new calibration standard/test fixture that enhances the integrity and reliability of the component characterization process has been developed. The fixture consists of 50 omega thru, reflect, delay, and device under test gold lines etched onto a 254 microns (0.010 in) thick alumina substrate. The Thru-Reflect-Line (TRL) fixture was tested at room temperature using a 30 omega, 7.62 mm (300 mil) long, gold line as a known standard. Good agreement between the experimental data and the data modelled using Sonnet's em(C) software was obtained for both the return (S(sub 11)) and insertion (S( 21)) losses. A gold two-pole bandpass filter with a 7.3 GHz center frequency was used as our Device Under Test (DUT), and the results compared with those obtained using a Short-Open-Load-Thru (SOLT) calibration technique.

  16. Decision Making in the Management of Extracapsular Fractures of the Proximal Femur – is the Dynamic Hip Screw the Prevailing Gold Standard?

    PubMed Central

    Jacob, Joshua; Desai, Ankit; Trompeter, Alex

    2017-01-01

    Currently, approximately half of all hip fractures are extracapsular, with an incidence as high as 50 in 100,000 in some countries. The common classification systems fail to explain the logistics of fracture classification and whether they all behave in the same manner. The Muller AO classification system is a useful platform to delineate stable and unstable fractures. The Dynamic hip screw (DHS) however, has remained the ‘gold standard’ implant of choice for application in all extracapsular fractures. The DHS relies on the integrity and strength of the lateral femoral wall as well as the postero-medial fragment. An analysis of several studies indicates significant improvements in design and techniques to ensure a better outcome with intramedullary nails. This article reviews the historical trends that helped to evolve the DHS implant as well as discussing if the surgeon should remain content with this implant. We suggest that the gold standard surgical management of extracapsular fractures can, and should, evolve. PMID:29290858

  17. The best choice of equipment to obtain high quality standardised results in intra-oral photography - a comparison between the common practice in the UK and the gold standard set by the literature.

    PubMed

    Marcato, Laura; Sandler, Jonathan

    2018-04-01

    Since digital technology made dental photography widely available, photographers have been trying to establish the 'gold standard' when obtaining intra-oral photographs. A basic knowledge of photographic principles, familiarity with particular dental techniques and a correct choice and use of equipment contribute significantly both to the standardisation and quality of photographs. A recent survey between members of the Institute of Medical Illustrators shed a light on the current practice in the UK. Medical photographers do not always have access to the full range of suitable equipment. A better selection of retractors and occlusal mirrors would undoubtedly contribute to higher quality images.

  18. European hospital adherence to GOLD recommendations for chronic obstructive pulmonary disease (COPD) exacerbation admissions.

    PubMed

    Roberts, C Michael; Lopez-Campos, Jose Luis; Pozo-Rodriguez, Francisco; Hartl, Sylvia

    2013-12-01

    Understanding how European care of chronic obstructive pulmonary disease (COPD) admissions vary against guideline standards provides an opportunity to target appropriate quality improvement interventions. In 2010-2011 an audit of care against the 2010 'Global initiative for chronic Obstructive Lung Disease' (GOLD) standards was performed in 16 018 patients from 384 hospitals in 13 countries. Clinicians prospectively identified consecutive COPD admissions over a period of 8 weeks, recording clinical care measures on a web-based data tool. Data were analysed comparing adherence to 10 key management recommendations. Adherence varied between hospitals and across countries. The lack of available spirometry results and variable use of oxygen and non-invasive ventilation (NIV) are high impact areas identified for improvement.

  19. Gold-standard evaluation of a folksonomy-based ontology learning model

    NASA Astrophysics Data System (ADS)

    Djuana, E.

    2018-03-01

    Folksonomy, as one result of collaborative tagging process, has been acknowledged for its potential in improving categorization and searching of web resources. However, folksonomy contains ambiguities such as synonymy and polysemy as well as different abstractions or generality problem. To maximize its potential, some methods for associating tags of folksonomy with semantics and structural relationships have been proposed such as using ontology learning method. This paper evaluates our previous work in ontology learning according to gold-standard evaluation approach in comparison to a notable state-of-the-art work and several baselines. The results show that our method is comparable to the state-of the art work which further validate our approach as has been previously validated using task-based evaluation approach.

  20. Building gold standard corpora for medical natural language processing tasks.

    PubMed

    Deleger, Louise; Li, Qi; Lingren, Todd; Kaiser, Megan; Molnar, Katalin; Stoutenborough, Laura; Kouril, Michal; Marsolo, Keith; Solti, Imre

    2012-01-01

    We present the construction of three annotated corpora to serve as gold standards for medical natural language processing (NLP) tasks. Clinical notes from the medical record, clinical trial announcements, and FDA drug labels are annotated. We report high inter-annotator agreements (overall F-measures between 0.8467 and 0.9176) for the annotation of Personal Health Information (PHI) elements for a de-identification task and of medications, diseases/disorders, and signs/symptoms for information extraction (IE) task. The annotated corpora of clinical trials and FDA labels will be publicly released and to facilitate translational NLP tasks that require cross-corpora interoperability (e.g. clinical trial eligibility screening) their annotation schemas are aligned with a large scale, NIH-funded clinical text annotation project.

Top