Brückner, G K; Linnane, S; Diaz, F; Vallat, B
2007-01-01
Two separate questionnaires were distributed to 20 OIE Collaborating Centres and 160 OIE Reference Laboratories to assess the current status of networking and collaboration among OIE Reference Laboratories and between OIE Reference Laboratories and OIE Collaborating Centres. The questionnaire for the OIE Reference Laboratories contained 7 sections with questions on networking between laboratories, reporting of information, biosecurity quality control, and financing. Emphasis was placed in obtaining information on inter-laboratory relationships and exchange of expertise, training needs and sharing of data and information. The questionnaire for the OIE Collaborating Centres contained six sections with the emphasis on aspects related to awareness of services that can be provided, expertise that could be made available, sharing of information and the relationship with the national veterinary services of the countries concerned. The responses to the questionnaires were collated, categorised and statistically evaluated to allow for tentative inferences on the data provided. Valuable information emanated from the data identifying the current status of networking and indicating possible shortcomings that could be addressed to improve networking.
Beermann, Sandra; Allerberger, Franz; Wirtz, Angela; Burger, Reinhard; Hamouda, Osamah
2015-10-01
In 1995, in agreement with the German Federal Ministry of Health, the Robert Koch Institute established a public health microbiology system consisting of national reference centers (NRCs) and consultant laboratories (CLs). The goal was to improve the efficiency of infection protection by advising the authorities on possible measures and to supplement infectious disease surveillance by monitoring selected pathogens that have high public health relevance. Currently, there are 19 NRCs and 40 CLs, each appointed for three years. In 2009, an additional system of national networks of NRCs and CLs was set up in order to enhance effectiveness and cooperation within the national reference laboratory system. The aim of these networks was to advance exchange in diagnostic methods and prevention concepts among reference laboratories and to develop geographic coverage of services. In the last two decades, the German public health laboratory reference system coped with all major infectious disease challenges. The European Union and the European Centre for Disease Prevention and Control (ECDC) are considering implementing a European public health microbiology reference laboratory system. The German reference laboratory system should be well prepared to participate actively in this upcoming endeavor. Copyright © 2015 Elsevier GmbH. All rights reserved.
Best, Michele; Sakande, Jean
2016-01-01
The role of national health laboratories in support of public health response has expanded beyond laboratory testing to include a number of other core functions such as emergency response, training and outreach, communications, laboratory-based surveillance and data management. These functions can only be accomplished by an efficient and resilient national laboratory network that includes public health, reference, clinical and other laboratories. It is a primary responsibility of the national health laboratory in the Ministry of Health to develop and maintain the national laboratory network in the country. In this article, we present practical recommendations based on 17 years of network development experience for the development of effective national laboratory networks. These recommendations and examples of current laboratory networks, are provided to facilitate laboratory network development in other states. The development of resilient, integrated laboratory networks will enhance each state's public health system and is critical to the development of a robust national laboratory response network to meet global health security threats.
2016-01-01
The role of national health laboratories in support of public health response has expanded beyond laboratory testing to include a number of other core functions such as emergency response, training and outreach, communications, laboratory-based surveillance and data management. These functions can only be accomplished by an efficient and resilient national laboratory network that includes public health, reference, clinical and other laboratories. It is a primary responsibility of the national health laboratory in the Ministry of Health to develop and maintain the national laboratory network in the country. In this article, we present practical recommendations based on 17 years of network development experience for the development of effective national laboratory networks. These recommendations and examples of current laboratory networks, are provided to facilitate laboratory network development in other states. The development of resilient, integrated laboratory networks will enhance each state’s public health system and is critical to the development of a robust national laboratory response network to meet global health security threats. PMID:28879137
Hennekinne, Jacques-Antoine; Gohier, Martine; Maire, Tiphaine; Lapeyre, Christiane; Lombard, Bertrand; Dragacci, Sylviane
2003-01-01
The European Commission has designed a network of European Union-National Reference Laboratories (EU-NRLs), coordinated by a Community Reference Laboratory (CRL), for control of hygiene of milk and milk products (Council Directive 92/46/ECC). As a common contaminant of milk and milk products such as cheese, staphylococcal enterotoxins are often involved in human outbreaks and should be monitored regularly. The main tasks of the EU-CRLs were to select and transfer to the EU-NRLs a reference method for detection of enterotoxins, and to set up proficiency testing to evaluate the competency of the European laboratory network. The first interlaboratory exercise was performed on samples of freeze-dried cheese inoculated with 2 levels of staphylococcal enterotoxins (0.1 and 0.25 ng/g) and on an uninoculated control. These levels were chosen considering the EU regulation for staphylococcal enterotoxins in milk and milk products and the limit of detection of the enzyme-linked immunosorbent assay test recommended in the reference method. The trial was conducted according to the recommendations of ISO Guide 43. Results produced by laboratories were compiled and compared through statistical analysis. Except for data from 2 laboratories for the uninoculated control and cheese inoculated at 0.1 ng/g, all laboratories produced satisfactory results, showing the ability of the EU-NRL network to monitor the enterotoxin contaminant.
Friedman, B A
2001-08-01
Major forces are now reshaping all businesses on a global basis, including the healthcare and clinical laboratory industries. One of the major forces at work is information technology (IT), which now provides the opportunity to create a new economic and business model for the clinical laboratory industry based on the creation of an integrated vertical meta-network, referred to here as the "total laboratory solution" (TLS). Participants at the most basic level of such a network would include a hospital-based laboratory, a reference laboratory, a laboratory information system/application service provider/laboratory portal vendor, an in vitro diagnostic manufacturer, and a pharmaceutical/biotechnology manufacturer. It is suggested that each of these participants would add value to the network primarily in its area of core competency. Subvariants of such a network have evolved over recent years, but a TLS comprising all or most of these participants does not exist at this time. Although the TLS, enabled by IT and closely akin to the various e-businesses that are now taking shape, offers many advantages from a theoretical perspective over the current laboratory business model, its success will depend largely on (a) market forces, (b) how the collaborative networks are organized and managed, and (c) whether the network can offer healthcare organizations higher quality testing services at lower cost. If the concept is successful, new demands will be placed on hospital-based laboratory professionals to shift the range of professional services that they offer toward clinical consulting, integration of laboratory information from multiple sources, and laboratory information management. These information management and integration tasks can only increase in complexity in the future as new genomic and proteomics testing modalities are developed and come on-line in clinical laboratories.
Establishing a China malaria diagnosis reference laboratory network for malaria elimination.
Yin, Jian-hai; Yan, He; Huang, Fang; Li, Mei; Xiao, Hui-hui; Zhou, Shui-sen; Xia, Zhi-gui
2015-01-28
In China, the prevalence of malaria has reduced dramatically due to the elimination programme. The continued success of the programme will depend upon the accurate diagnosis of the disease in the laboratory. The basic requirements for this are a reliable malaria diagnosis laboratory network and quality management system to support case verification and source tracking. The baseline information of provincial malaria laboratories in the China malaria diagnosis reference laboratory network was collected and analysed, and a quality-assurance activity was carried out to assess their accuracies in malaria diagnosis by microscopy using WHO standards and PCR. By the end of 2013, nineteen of 24 provincial laboratories have been included in the network. In the study, a total of 168 staff were registered and there was no bias in their age, gender, education level, and position. Generally Plasmodium species were identified with great accuracy by microscopy and PCR. However, Plasmodium ovale was likely to be misdiagnosed as Plasmodium vivax by microscopy. China has established a laboratory network for primary malaria diagnosis which will cover a larger area. Currently, Plasmodium species can be identified fairly accurately by microscopy and PCR. However, laboratory staff need additional trainings on accurate identification of P. ovale microscopically and good performance of PCR operations.
Development of the Global Measles Laboratory Network.
Featherstone, David; Brown, David; Sanders, Ray
2003-05-15
The routine reporting of suspected measles cases and laboratory testing of samples from these cases is the backbone of measles surveillance. The Global Measles Laboratory Network (GMLN) has developed standards for laboratory confirmation of measles and provides training resources for staff of network laboratories, reference materials and expertise for the development and quality control of testing procedures, and accurate information for the Measles Mortality Reduction and Regional Elimination Initiative. The GMLN was developed along the lines of the successful Global Polio Laboratory Network, and much of the polio laboratory infrastructure was utilized for measles. The GMLN has developed as countries focus on measles control activities following successful eradication of polio. Currently more than 100 laboratories are part of the global network and follow standardized testing and reporting procedures. A comprehensive laboratory accreditation process will be introduced in 2002 with six quality assurance and performance indicators.
Towards the distribution network of time and frequency
NASA Astrophysics Data System (ADS)
Lipiński, M.; Krehlik, P.; Śliwczyński, Ł.; Buczek, Ł.; Kołodziej, J.; Nawrocki, J.; Nogaś, P.; Dunst, P.; Lemański, D.; Czubla, A.; Pieczerak, J.; Adamowicz, W.; Pawszak, T.; Igalson, J.; Binczewski, A.; Bogacki, W.; Ostapowicz, P.; Stroiński, M.; Turza, K.
2014-05-01
In the paper the genesis, current stage and perspectives of the OPTIME project are described. The main goal of the project is to demonstrate that the newdeveloped at AGH technology of fiber optic transfer of the atomic clocks reference signals is ready to be used in building the domestic Time and Frequency distribution network. In the first part we summarize the two-year continuous operation of 420 kmlong link connecting the Laboratory of Time and Frequency at Central Office of Measures GUM in Warsaw and Time Service Laboratory at Astrogeodynamic Obserwatory AOS in Borowiec near Poznan. For the first time, we are reporting the two year comparison of UTC(PL) and UTC(AOS) atomic timescales with this link, and we refer it to the results of comparisons performed by GPS-based methods. We also address some practical aspects of maintaining time and frequency dissemination over fiber optical network. In the second part of the paper the concept of the general architecture of the distribution network with two Reference Time and Frequency Laboratories and local repositories is proposed. Moreover the brief project of the second branch connecting repositories in Poznan Polish Supercomputing and Networking Center and Torun Nicolaus Copernicus University with the first end-users in Torun such as National Laboratory of Atomic, Molecular and Optical Physics and Nicolaus Copernicus Astronomical Center is described. In the final part the perspective of developing the network both in the domestic range as far as extention with the international connections possibilities are presented.
Extensively Drug-Resistant Tuberculosis (XDR TB)
... TB Reference Laboratory Network, the National TB Surveillance System in the United States, the national reference laboratory of South Korea, and ... capacity in the U.S. and abroad; and Developing education, risk, and media communications ... – United States, 1993–2006 CDC. CDC’s Role in Preventing XDR ...
de Ory, Fernando; Sanz, Juan Carlos; Echevarría, Juan Emilio; Mosquera, María del Mar; Guisasola, María Eulalia
2004-01-01
The comparison of serological methods used by the laboratories participating in the Network for the Elimination of Measles to diagnose measles virus infection as well as differential diagnosis with other exanthematic diseases are compared. One panel of 20 serum samples including measles (12), rubella (4), parvovirus B19 (2) and dengue (2) infections was established. All cases were diagnosed by detection of specific IgM. The panel was sent to the laboratories of the Network. The results were compared with those obtained at the reference laboratory. Regarding measles, IgM response from 20 laboratories (19 by ELISA and 1 by indirect immunofluorescence) was obtained, with an agreement of 91.5%. Related to rubella IgM, replay from 6 laboratories, using ELISA, was received, with an agreement of 98.7%. With respect to parvovirus B19 IgM, response from 10 laboratories (8 by ELISA and 2 by indirect immunofluorescence) was obtained, with an agreement of 94.6%. Results about dengue virus were not reported by any laboratory. Some laboratories from the network should review the methods used for the diagnosis of measles and other exanthematic diseases. The results reassert the need for a reference laboratory to support confirmation of the results.
The NCI has awarded 18 grants to continue the Early Detection Research Network (EDRN), a national infrastructure that supports the integrated development, validation, and clinical application of biomarkers for the early detection of cancer. The awards fund 7 Biomarker Developmental Laboratories, 8 Clinical Validation Centers, 2 Biomarker Reference Laboratories, and a Data
Nisii, C; Castilletti, C; Di Caro, A; Capobianchi, M R; Brown, D; Lloyd, G; Gunther, S; Lundkvist, A; Pletschette, M; Ippolito, G
2009-08-01
Emerging and re-emerging infections and possible bioterrorism acts will continue to challenge both the medical community and civilian populations worldwide, urging health authorities to respond rapidly and effectively. Established in 2005, the European Community (EC)-funded European Network of Biosafety-Level-4 laboratories (Euronet-P4), which brings together the laboratories in Porton Down, London, Hamburg, Marburg, Solna, Lyon and Rome, seeks to increase international collaboration in the areas of high containment laboratory biosafety and viral diagnostic capability, to strengthen Europe's capacity to respond to an infectious disease emergency, and to offer assistance to countries not equipped with such costly facilities. Network partners have agreed on a common strategy to fill the gaps identified in the field of risk group-4 agents' laboratory diagnosis, namely the lack of standardization and of reference samples. The network has received a further 3-year funding, to offer assistance to external laboratories, and to start the planning of field activities.
A soil sampling intercomparison exercise for the ALMERA network.
Belli, Maria; de Zorzi, Paolo; Sansone, Umberto; Shakhashiro, Abduhlghani; Gondin da Fonseca, Adelaide; Trinkl, Alexander; Benesch, Thomas
2009-11-01
Soil sampling and analysis for radionuclides after an accidental or routine release is a key factor for the dose calculation to members of the public, and for the establishment of possible countermeasures. The IAEA organized for selected laboratories of the ALMERA (Analytical Laboratories for the Measurement of Environmental Radioactivity) network a Soil Sampling Intercomparison Exercise (IAEA/SIE/01) with the objective of comparing soil sampling procedures used by different laboratories. The ALMERA network is a world-wide network of analytical laboratories located in IAEA member states capable of providing reliable and timely analysis of environmental samples in the event of an accidental or intentional release of radioactivity. Ten ALMERA laboratories were selected to participate in the sampling exercise. The soil sampling intercomparison exercise took place in November 2005 in an agricultural area qualified as a "reference site", aimed at assessing the uncertainties associated with soil sampling in agricultural, semi-natural, urban and contaminated environments and suitable for performing sampling intercomparison. In this paper, the laboratories sampling performance were evaluated.
Environmental Response Laboratory Network (ERLN) WebEDR Quick Reference Guide
The Web Electronic Data Review is a web-based system that performs automated data processing on laboratory-submitted Electronic Data Deliverables (EDDs). Enables users to perform technical audits on data, and against Measurement Quality Objectives (MQOs).
NASA Astrophysics Data System (ADS)
Phister, P. W., Jr.
1983-12-01
Development of the Air Force Institute of Technology's Digital Engineering Laboratory Network (DELNET) was continued with the development of an initial draft of a protocol standard for all seven layers as specified by the International Standards Organization's (ISO) Reference Model for Open Systems Interconnections. This effort centered on the restructuring of the Network Layer to perform Datagram routing and to conform to the developed protocol standards and actual software module development of the upper four protocol layers residing within the DELNET Monitor (Zilog MCZ 1/25 Computer System). Within the guidelines of the ISO Reference Model the Transport Layer was developed utilizing the Internet Header Format (IHF) combined with the Transport Control Protocol (TCP) to create a 128-byte Datagram. Also a limited Application Layer was created to pass the Gettysburg Address through the DELNET. This study formulated a first draft for the DELNET Protocol Standard and designed, implemented, and tested the Network, Transport, and Application Layers to conform to these protocol standards.
Michelon, Damien; Félix, Benjamin; Vingadassalon, Noemie; Mariet, Jean-François; Larsson, Jonas T; Møller-Nielsen, Eva; Roussel, Sophie
2015-03-01
Listeria monocytogenes is a foodborne pathogen responsible for a severe disease known as listeriosis. The European Centre for Disease Prevention and Control (ECDC) coordinates a network of national public health laboratories (NPHLs) in charge of typing clinical strains. In food, it is the European Union Reference Laboratory for L. monocytogenes (EURL Lm), which manages a network of National Reference Laboratories (NRLs). A pulsed-field gel electrophoresis (PFGE) standard operating procedure (EURL SOP) has been used routinely at the EURL Lm since 2007. The EURL Lm has recommended that NRLs use the EURL SOP, whereas the Statens Serum Institut (SSI), under contract for ECDC, requested that NPHLs use Halpins' SOP (HSOP) published in 2010 for the PulseNet USA network. An update of Halpins' SOP (uHSOP) was published in 2013. To facilitate the exchange of profiles among human and food European reference laboratories, it is crucial to ensure that the PFGE profiles obtained with these different SOPs are comparable. The aim here was to compare the EURL SOP with HSOP and uHSOP. The panel comprised 114 well-characterized SSI/EURL strains. All were characterized at the EURL using both the EURL SOP and uHSOP. Seventy of the 114 strains were also characterized at the SSI using HSOP. The EURL SOP and uHSOP produced indistinguishable combined (ApaI/AscI) profiles for the 114 strains tested. The EURL SOP and HSOP produced indistinguishable combined profiles for 69 of the 70 strains tested. One strain displayed for the AscI profile an additional low-intensity band at 184 kbp with HSOP. For this strain, SSI and EUR Lm had already observed the same profile from NPHLs and NRLs. However, this deviation is minor as it accounted for about 1% of all the 114 combined profiles. This study should facilitate the exchange of reproducible PFGE profiles among human and food reference laboratories.
PIV Logon Configuration Guidance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Glen Alan
This document details the configurations and enhancements implemented to support the usage of federal Personal Identity Verification (PIV) Card for logon on unclassified networks. The guidance is a reference implementation of the configurations and enhancements deployed at the Los Alamos National Laboratory (LANL) by Network and Infrastructure Engineering – Core Services (NIE-CS).
2010-01-01
Background The Worldwide Antimalarial Resistance Network (WWARN) is a global collaboration to support the objective that anyone affected by malaria receives effective and safe drug treatment. The Pharmacology module aims to inform optimal anti-malarial drug selection. There is an urgent need to define the drug exposure - effect relationship for most anti-malarial drugs. Few anti-malarials have had their therapeutic blood concentration levels defined. One of the main challenges in assessing safety and efficacy data in relation to drug concentrations is the comparability of data generated from different laboratories. To explain differences in anti-malarial pharmacokinetics in studies with different measurement laboratories it is necessary to confirm the accuracy of the assay methods. This requires the establishment of an external quality assurance process to assure results that can be compared. This paper describes this process. Methods The pharmacology module of WWARN has established a quality assurance/quality control (QA/QC) programme consisting of two separate components: 1. A proficiency testing programme where blank human plasma spiked with certified reference material (CRM) in different concentrations is sent out to participating bioanalytical laboratories. 2. A certified reference standard programme where accurately weighed amounts of certified anti-malarial reference standards, metabolites, and internal standards are sent to participating bioanalytical and in vitro laboratories. Conclusion The proficiency testing programme is designed as a cooperative effort to help participating laboratories assess their ability to carry out drug analysis, resolve any potential problem areas and to improve their results - and, in so doing, to improve the quality of anti-malarial pharmacokinetic data published and shared with WWARN. By utilizing the same source of standards for all laboratories, it is possible to minimize bias arising from poor quality reference standards. By providing anti-malarial drug standards from a central point, it is possible to lower the cost of these standards. PMID:21184684
[The National Reference Centres and Reference Laboratories. Importance and tasks].
Laude, G; Ammon, A
2005-09-01
Since 1995, the German Federal Ministry for Health and Social Security funds National Reference Centres (NRC) for the laboratory surveillance of important pathogens and syndromes. Which pathogens or syndromes are selected to be covered by a NRC depends on their epidemiological relevance, the special diagnostic tools, problems with antimicrobial resistance and necessary infection control measures. Currently, there are 15 NRC, which are appointed for a period of 3 years (currently from January 2005 through December 2007). Towards the end of their appointment all NRC are evaluated by a group of specialists. The assessment of their achievements is guided by a catalogue of tasks for the NRC. In addition to the NRC, a total of 50 laboratories are appointed which provide specialist expertise for additional pathogens in order to have a broad range of pathogens for which specialist laboratories are available. Their predominant task is to give advice and support for special diagnostic problems. Both NRC and the specialist laboratories are important parts of the network for infectious disease epidemiology.
Huet, S; Marie, J P; Gualde, N; Robert, J
1998-12-15
Multidrug resistance (MDR) associated with overexpression of the MDR1 gene and of its product, P-glycoprotein (Pgp), plays an important role in limiting cancer treatment efficacy. Many studies have investigated Pgp expression in clinical samples of hematological malignancies but failed to give definitive conclusion on its usefulness. One convenient method for fluorescent detection of Pgp in malignant cells is flow cytometry which however gives variable results from a laboratory to another one, partly due to the lack of a reference method rigorously tested. The purpose of this technical note is to describe each step of a reference flow cytometric method. The guidelines for sample handling, staining and analysis have been established both for Pgp detection with monoclonal antibodies directed against extracellular epitopes (MRK16, UIC2 and 4E3), and for Pgp functional activity measurement with Rhodamine 123 as a fluorescent probe. Both methods have been validated on cultured cell lines and clinical samples by 12 laboratories of the French Drug Resistance Network. This cross-validated multicentric study points out crucial steps for the accuracy and reproducibility of the results, like cell viability, data analysis and expression.
Sources and performance criteria of uncertainty of reference measurement procedures.
Mosca, Andrea; Paleari, Renata
2018-05-29
This article wants to focus on the today available Reference Measurement Procedures (RMPs) for the determination of various analytes in Laboratory Medicine and the possible tools to evaluate their performance in the laboratories who are currently using them. A brief review on the RMPs has been performed by investigating the Joint Committee for Traceability in Laboratory Medicine (JCTLM) database. In order to evaluate their performances, we have checked the organization of three international ring trials, i.e. those regularly performed by the IFCC External Quality assessment scheme for Reference Laboratories in Laboratory Medicine (RELA), by the Center for Disease Control and Prevention (CDC) cholesterol network and by the IFCC Network for HbA 1c . Several RMPs are available through the JCTLM database, but the best way to collect information about the RMPs and their uncertainties is to look at the reference measurement service providers (RMS). This part of the database and the background on how to listed in the database is very helpful for the assessment of expanded uncertainty (MU) and performance in general of RMPs. Worldwide, 17 RMS are listed in the database, and for most of the measurands more than one RMS is able to run the relative RMPs, with similar expanded uncertainties. As an example, for a-amylase, 4 SP offer their services with MU between 1.6 and 3.3%. In other cases (such as total cholesterol, the U may span over a broader range, i.e. from 0.02 to 3.6%). With regard to the performance evaluation, the approach is often heterogenous, and it is difficult to compare the performance of laboratories running the same RMP for the same measurand if involved in more than one EQAS. The reference measurement services have been created to help laboratory professionals and manufacturers to implement the correct metrological traceability, and the JCTLM database is the only correct way to retrieve all the necessary important information to this end. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Utzinger, J; Botero-Kleiven, S; Castelli, F; Chiodini, P L; Edwards, H; Köhler, N; Gulletta, M; Lebbad, M; Manser, M; Matthys, B; N'Goran, E K; Tannich, E; Vounatsou, P; Marti, H
2010-03-01
The present study aimed to compare the diagnostic performance of different European reference laboratories in diagnosing helminths and intestinal protozoa, using an ether-concentration method applied to sodium acetate-acetic acid-formalin (SAF)-preserved faecal samples. In total, 102 stool specimens were analysed during a cross-sectional parasitological survey in urban farming communities in Côte d'Ivoire. Five SAF-preserved faecal samples were prepared from each specimen and forwarded to the participating reference laboratories, processed and examined under a microscope adhering to a standard operating procedure (SOP). Schistosoma mansoni (cumulative prevalence: 51.0%) and hookworm (cumulative prevalence: 39.2%) were the predominant helminths. There was excellent agreement (kappa > 0.8; p < 0.001) among the reference laboratories for the diagnosis of S. mansoni, hookworm, Trichuris trichiura and Ascaris lumbricoides. Moderate agreement (kappa = 0.54) was found for Hymenolepis nana, and lesser agreement was observed for other, less prevalent helminths. The predominant intestinal protozoa were Entamoeba coli (median prevalence: 67.6%), Blastocystis hominis (median prevalence: 55.9%) and Entamoeba histolytica/Entamoeba dispar (median prevalence: 47.1%). Substantial agreement among reference laboratories was found for E. coli (kappa = 0.69), but only fair or moderate agreement was found for other Entamoeba species, Giardia intestinalis and Chilomastix mesnili. There was only poor agreement for B. hominis, Isospora belli and Trichomonas intestinalis. In conclusion, although common helminths were reliably diagnosed by European reference laboratories, there was only moderate agreement between centres for pathogenic intestinal protozoa. Continued external quality assessment and the establishment of a formal network of reference laboratories is necessary to further enhance both accuracy and uniformity in parasite diagnosis.
International External Quality Assurance for Laboratory Diagnosis of Diphtheria ▿
Neal, S. E.; Efstratiou, A.
2009-01-01
The diphtheria surveillance network (DIPNET) encompassing National Diphtheria Reference Centers from 25 European countries is a Dedicated Surveillance Network recognized by the European Commission. A key DIPNET objective is the quality assessment of microbiological procedures for diphtheria across the European Union and beyond. A detailed questionnaire on the level of reference laboratory services and an external quality assessment (EQA) panel comprising six simulated throat specimens were sent to 34 centers. Twenty-three centers are designated National Diphtheria Reference Centers, with the laboratory in the United Kingdom being the only WHO Collaborating Centre. A variety of screening and identification tests were used, including the cysteinase test (20/34 centers), pyrazinamidase test (17/34 centers), and commercial kits (25/34 centers). The classic Elek test for toxigenicity testing is mostly used (28/34 centers), with variations in serum sources and antitoxin concentrations. Many laboratories reported problems obtaining Elek reagents or media. Only six centers produced acceptable results for all six specimens. Overall, 21% of identification and 13% of toxigenicity reports were unacceptable. Many centers could not isolate the target organism, and most found difficulties with the specimens that contained Corynebacterium striatum as a commensal contaminant. Nineteen centers generated either false-positive or negative toxigenic results, which may have caused inappropriate medical management. The discrepancies in this diphtheria diagnostics EQA alarmingly reflect the urgent need to improve laboratory performance in diphtheria diagnostics in Europe, standardize feasible and robust microbiological methods, and build awareness among public health authorities. Therefore, DIPNET recommends that regular workshops and EQA distributions for diphtheria diagnostics should be supported and maintained. PMID:19828749
Practical applications of hand-held computers in dermatology.
Goldblum, Orin M
2002-09-01
For physicians, hand-held computers are gaining popularity as point of care reference tools. The convergence of hand-held computers, the Internet, and wireless networks will enable these devices to assume more essential roles as mobile transmitters and receivers of digital medical Information. In addition to serving as portable medical reference sources, these devices can be Internet-enabled, allowing them to communicate over wireless wide and local area networks. With enhanced wireless connectivity, hand-held computers can be used at the point of patient care for charge capture, electronic prescribing, laboratory test ordering, laboratory result retrieval, web access, e-mail communication, and other clinical and administrative tasks. Physicians In virtually every medical specialty have begun using these devices in various ways. This review of hand-held computer use in dermatology illustrates practical examples of the many different ways hand-held computers can be effectively used by the practicing dermatologist.
Analysis of Thiodiglycol: Validation of Semi-Volatile Analysis by HPLC-MS/MS by EPA Method MS777
DOE Office of Scientific and Technical Information (OSTI.GOV)
Owens, J; Koester, C
The Environmental Protection Agency's (EPA) Region 5 Chicago Regional Laboratory (CRL) developed a method for the analysis of thiodiglycol, the breakdown product of the sulfur mustard HD, in water by high performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS), titled Method EPA MS777 (hereafter referred to as EPA CRL SOP MS777). This draft standard operating procedure (SOP) was distributed to multiple EPA laboratories and to Lawrence Livermore National Laboratory, which was tasked to serve as a reference laboratory for EPA's Environmental Reference Laboratory Network (ERLN) and to develop and validate analytical procedures. The primary objective of this study was to verifymore » the analytical procedures described in MS777 for analysis of thiodiglycol in aqueous samples. The gathered data from this study will be used to: (1) demonstrate analytical method performance; (2) generate quality control acceptance criteria; and (3) revise the SOP to provide a validated method that would be available for use during a homeland security event. The data contained in this report will be compiled, by EPA CRL, with data generated by other EPA Regional laboratories so that performance metrics of Method EPA MS777 can be determined.« less
Guillot, Sophie; Guiso, Nicole
2016-08-01
The French National Reference Centre (NRC) for Whooping Cough carried out an external quality control (QC) analysis in 2010 for the PCR diagnosis of whooping cough. The main objective of the study was to assess the impact of this QC in the participating laboratories through a repeat analysis in 2012. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Practical use of a framework for network science experimentation
NASA Astrophysics Data System (ADS)
Toth, Andrew; Bergamaschi, Flavio
2014-06-01
In 2006, the US Army Research Laboratory (ARL) and the UK Ministry of Defence (MoD) established a collaborative research alliance with academia and industry, called the International Technology Alliance (ITA)1 In Network and Information Sciences, to address fundamental issues concerning Network and Information Sciences that will enhance decision making for coalition operations and enable rapid, secure formation of ad hoc teams in coalition environments and enhance US and UK capabilities to conduct coalition warfare. Research conducted under the ITA was extended through collaboration between ARL and IBM UK to characterize and dene a software stack and tooling that has become the reference framework for network science experimentation in support for validation of theoretical research. This paper discusses the composition of the reference framework for experimentation resulting from the ARL/IBM UK collaboration and its use, by the Network Science Collaborative Technology Alliance (NS CTA)2 , in a recent network science experiment conducted at ARL. It also discusses how the experiment was modeled using the reference framework, the integration of two new components, the Apollo Fact-Finder3 tool and the Medusa Crowd Sensing4 application, the limitations identified and how they shall be addressed in future work.
The Second National Ballistics Imaging Comparison (NBIC-2)
Vorburger, TV; Yen, J; Song, JF; Thompson, RM; Renegar, TB; Zheng, A; Tong, M; Ols, M
2014-01-01
In response to the guidelines issued by the American Society of Crime Laboratory Directors/Laboratory Accreditation Board (ASCLD/LAB-International) to establish traceability and quality assurance in U.S. crime laboratories, NIST and the ATF initiated a joint project, entitled the National Ballistics Imaging Comparison (NBIC). The NBIC project aims to establish a national traceability and quality system for ballistics identifications in crime laboratories utilizing ATF’s National Integrated Ballistics Information Network (NIBIN). The original NBIC was completed in 2010. In the second NBIC, NIST Standard Reference Material (SRM) 2461 Cartridge Cases were used as reference standards, and 14 experts from 11 U.S. crime laboratories each performed 17 image acquisitions and correlations of the SRM cartridge cases over the course of about half a year. Resulting correlation scores were collected by NIST for statistical analyses, from which control charts and control limits were developed for the proposed quality system and for promoting future assessments and accreditations for firearm evidence in U.S. forensic laboratories in accordance with the ISO 17025 Standard. PMID:26601051
The Second National Ballistics Imaging Comparison (NBIC-2).
Vorburger, T V; Yen, J; Song, J F; Thompson, R M; Renegar, T B; Zheng, A; Tong, M; Ols, M
2014-01-01
In response to the guidelines issued by the American Society of Crime Laboratory Directors/Laboratory Accreditation Board (ASCLD/LAB-International) to establish traceability and quality assurance in U.S. crime laboratories, NIST and the ATF initiated a joint project, entitled the National Ballistics Imaging Comparison (NBIC). The NBIC project aims to establish a national traceability and quality system for ballistics identifications in crime laboratories utilizing ATF's National Integrated Ballistics Information Network (NIBIN). The original NBIC was completed in 2010. In the second NBIC, NIST Standard Reference Material (SRM) 2461 Cartridge Cases were used as reference standards, and 14 experts from 11 U.S. crime laboratories each performed 17 image acquisitions and correlations of the SRM cartridge cases over the course of about half a year. Resulting correlation scores were collected by NIST for statistical analyses, from which control charts and control limits were developed for the proposed quality system and for promoting future assessments and accreditations for firearm evidence in U.S. forensic laboratories in accordance with the ISO 17025 Standard.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grant, Ryan E.; Barrett, Brian W.; Pedretti, Kevin
The Portals reference implementation is based on the Portals 4.X API, published by Sandia National Laboratories as a freely available public document. It is designed to be an implementation of the Portals Networking Application Programming Interface and is used by several other upper layer protocols like SHMEM, GASNet and MPI. It is implemented over existing networks, specifically Ethernet and InfiniBand networks. This implementation provides Portals networks functionality and serves as a software emulation of Portals compliant networking hardware. It can be used to develop software using the Portals API prior to the debut of Portals networking hardware, such as Bull’smore » BXI interconnect, as well as a substitute for portals hardware on development platforms that do not have Portals compliant hardware. The reference implementation provides new capabilities beyond that of a typical network, namely the ability to have messages matched in hardware in a way compatible with upper layer software such as MPI or SHMEM. It also offers methods of offloading network operations via triggered operations, which can be used to create offloaded collective operations. Specific details on the Portals API can be found at http://portals4.org.« less
Quality assurance in the HIV/AIDS laboratory network of China.
Jiang, Yan; Qiu, Maofeng; Zhang, Guiyun; Xing, Wenge; Xiao, Yao; Pan, Pinliang; Yao, Jun; Ou, Chin-Yih; Su, Xueli
2010-12-01
In 2009, there were 8273 local screening laboratories, 254 confirmatory laboratories, 35 provincial confirmatory central laboratories and 1 National AIDS Reference Laboratory (NARL) in China. These laboratories were located in Center for Disease Control and Prevention (CDC) facilities, hospitals, blood donation clinics, maternal and child health (MCH) hospitals and border health quarantine health-care facilities. The NARL and provincial laboratories provide quality assurance through technical, bio-safety and managerial training; periodic proficiency testing; on-site supervisory inspections; and commercial serologic kit evaluations. From 2002 to 2009, more than 220 million HIV antibody tests were performed at screening laboratories, and all reactive and indeterminate samples were confirmed at confirmatory laboratories. The use of highly technically complex tests, including CD4 cell enumeration, viral load, dried blood spot (DBS)-based early infant diagnosis (EID), drug resistance (DR) genotyping, HIV-1 subtyping and incidence assays, have increased in recent years and their performance quality is closely monitored. China has made significant progress in establishing a well-coordinated HIV laboratory network and QA systems. However, the coverage and intensity of HIV testing and quality assurance programmes need to be strengthened so as to ensure that more infected persons are diagnosed and that they receive timely prevention and treatment services.
[The role of reference laboratories in animal health programmes in South America].
Bergmann, I E
2003-08-01
The contribution of the Panamerican Foot and Mouth Disease (FMD) Centre (PANAFTOSA), as an OIE (World organisation for animal health) regional reference laboratory for the diagnosis of FMD and vesicular stomatitis, and for the control of the FMD vaccine, has been of fundamental importance to the development, implementation and harmonisation of modern laboratory procedures in South America. The significance of the work conducted by PANAFTOSA is particularly obvious when one considers the two pillars on which eradication programmes are based, namely: a well-structured regional laboratory network, and the creation of a system which allows technology and new developments to be transferred to Member Countries as quickly and efficiently as possible. Over the past decade, PANAFTOSA has kept pace with the changing epidemiological situation on the continent, and with developments in the international political and economical situation. This has involved the strengthening of quality policies, and the elaboration and implementation of diagnostic tools that make for more thorough epidemiological analyses. The integration of PANAFTOSA into the network of national laboratories and its cooperation with technical and scientific institutes, universities and the private sector means that local needs can be met, thanks to the design and rapid implementation of methodological tools which are validated using internationally accepted criteria. This collaboration, which ensures harmonisation of laboratory tests and enhances the quality of national Veterinary Services, serves to promote greater equity, a prerequisite for regional eradication strategies and this in turn, helps to increase competitiveness in the region.
Lourens, Chris; Lindegardh, Niklas; Barnes, Karen I.; Guerin, Philippe J.; Sibley, Carol H.; White, Nicholas J.
2014-01-01
Comprehensive assessment of antimalarial drug resistance should include measurements of antimalarial blood or plasma concentrations in clinical trials and in individual assessments of treatment failure so that true resistance can be differentiated from inadequate drug exposure. Pharmacometric modeling is necessary to assess pharmacokinetic-pharmacodynamic relationships in different populations to optimize dosing. To accomplish both effectively and to allow comparison of data from different laboratories, it is essential that drug concentration measurement is accurate. Proficiency testing (PT) of laboratory procedures is necessary for verification of assay results. Within the Worldwide Antimalarial Resistance Network (WWARN), the goal of the quality assurance/quality control (QA/QC) program is to facilitate and sustain high-quality antimalarial assays. The QA/QC program consists of an international PT program for pharmacology laboratories and a reference material (RM) program for the provision of antimalarial drug standards, metabolites, and internal standards for laboratory use. The RM program currently distributes accurately weighed quantities of antimalarial drug standards, metabolites, and internal standards to 44 pharmacology, in vitro, and drug quality testing laboratories. The pharmacology PT program has sent samples to eight laboratories in four rounds of testing. WWARN technical experts have provided advice for correcting identified problems to improve performance of subsequent analysis and ultimately improved the quality of data. Many participants have demonstrated substantial improvements over subsequent rounds of PT. The WWARN QA/QC program has improved the quality and value of antimalarial drug measurement in laboratories globally. It is a model that has potential to be applied to strengthening laboratories more widely and improving the therapeutics of other infectious diseases. PMID:24777099
Moreno, Lilliana I; Brown, Alice L; Callaghan, Thomas F
2017-07-01
Rapid DNA platforms are fully integrated systems capable of producing and analyzing short tandem repeat (STR) profiles from reference sample buccal swabs in less than two hours. The technology requires minimal user interaction and experience making it possible for high quality profiles to be generated outside an accredited laboratory. The automated production of point of collection reference STR profiles could eliminate the time delay for shipment and analysis of arrestee samples at centralized laboratories. Furthermore, point of collection analysis would allow searching against profiles from unsolved crimes during the normal booking process once the infrastructure to immediately search the Combined DNA Index System (CODIS) database from the booking station is established. The DNAscan/ANDE™ Rapid DNA Analysis™ System developed by Network Biosystems was evaluated for robustness and reliability in the production of high quality reference STR profiles for database enrollment and searching applications. A total of 193 reference samples were assessed for concordance of the CODIS 13 loci. Studies to evaluate contamination, reproducibility, precision, stutter, peak height ratio, noise and sensitivity were also performed. The system proved to be robust, consistent and dependable. Results indicated an overall success rate of 75% for the 13 CODIS core loci and more importantly no incorrect calls were identified. The DNAscan/ANDE™ could be confidently used without human interaction in both laboratory and non-laboratory settings to generate reference profiles. Published by Elsevier B.V.
Land, Sally; Cunningham, Philip; Zhou, Jialun; Frost, Kevin; Katzenstein, David; Kantor, Rami; Chen, Yi-Ming Arthur; Oka, Shinichi; DeLong, Allison; Sayer, David; Smith, Jeffery; Dax, Elizabeth M.; Law, Matthew
2010-01-01
The TREAT Asia (Therapeutics, Research, Education, and AIDS Training in Asia) Network is building capacity for Human Immunodeficiency Virus Type-1 (HIV-1) drug resistance testing in the region. The objective of the TREAT Asia Quality Assessment Scheme – designated TAQAS – is to standardize HIV-1 genotypic resistance testing (HIV genotyping) among laboratories to permit rigorous comparison of results from different clinics and testing centres. TAQAS has evaluated three panels of HIV-1-positive plasma from clinical material or low-passage, culture supernatant for up to 10 Asian laboratories. Laboratory participants used their standard protocols to perform HIV genotyping. Assessment was in comparison to a target genotype derived from all participants and the reference laboratory’s result. Agreement between most participants at the edited nucleotide sequence level was high (>98%). Most participants performed to the reference laboratory standard in detection of drug resistance mutations (DRMs). However, there was variation in the detection of nucleotide mixtures (0–83%) and a significant correlation with the detection of DRMs (p < 0.01). Interpretation of antiretroviral resistance showed ~70% agreement among participants when different interpretation systems were used but >90% agreement with a common interpretation system, within the Stanford University Drug Resistance Database. Using the principles of external quality assessment and a reference laboratory, TAQAS has demonstrated high quality HIV genotyping results from Asian laboratories. PMID:19490972
The National Ballistics Imaging Comparison (NBIC) project.
Song, J; Vorburger, T V; Ballou, S; Thompson, R M; Yen, J; Renegar, T B; Zheng, A; Silver, R M; Ols, M
2012-03-10
In response to the guidelines issued by the American Society of Crime Laboratory Directors/Laboratory Accreditation Board (ASCLD/LAB-International) to establish traceability and quality assurance in U.S. crime laboratories, a NIST/ATF joint project entitled National Ballistics Imaging Comparison (NBIC) was initialized in 2008. The NBIC project aims to establish a National Traceability and Quality System for ballistics identifications in crime laboratories within the National Integrated Ballistics Information Network (NIBIN) of the U.S. NIST Standard Reference Material (SRM) 2460 bullets and 2461 cartridge cases are used as reference standards. 19 ballistics examiners from 13 U.S. crime laboratories participated in this project. They each performed 24 periodic image acquisitions and correlations of the SRM bullets and cartridge cases over the course of a year, but one examiner only participated in Phase 1 tests of SRM cartridge case. The correlation scores were collected by NIST for statistical analyses, from which control charts and control limits were developed for the proposed Quality System and for promoting future assessments and accreditations for firearm evidence in U.S. forensic laboratories in accordance with the ISO 17025 Standard. Published by Elsevier Ireland Ltd.
Burkholderia pseudomallei: Challenges for the Clinical Microbiology Laboratory.
Hemarajata, Peera; Baghdadi, Jonathan D; Hoffman, Risa; Humphries, Romney M
2016-12-01
Melioidosis is a potentially fatal infection caused by the bacterium Burkholderia pseudomallei Clinical diagnosis of melioidosis can be challenging since there is no pathognomonic clinical syndrome, and the organism is often misidentified by methods used routinely in clinical laboratories. Although the disease is more prevalent in Thailand and northern Australia, sporadic cases may be encountered in areas where it is not endemic, including the United States. Since the organism is considered a tier 1 select agent according to the Centers for Disease Control and Prevention and the U.S. Department of Agriculture Animal and Plant Health Inspection Service, clinical laboratories must be proficient at rapidly recognizing isolates suspicious for B. pseudomallei, be able to safely perform necessary rule-out tests, and to refer suspect isolates to Laboratory Response Network reference laboratories. In this minireview, we report a case of melioidosis encountered at our institution and discuss the laboratory challenges encountered when dealing with clinical isolates suspicious for B. pseudomallei or clinical specimens from suspected melioidosis cases. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Strengthening systems for communicable disease surveillance: creating a laboratory network in Rwanda
2011-01-01
Background The recent emergence of a novel strain of influenza virus with pandemic potential underscores the need for quality surveillance and laboratory services to contribute to the timely detection and confirmation of public health threats. To provide a framework for strengthening disease surveillance and response capacities in African countries, the World Health Organization Regional Headquarters for Africa (AFRO) developed Integrated Disease Surveillance and Response (IDSR) aimed at improving national surveillance and laboratory systems. IDSR emphasizes the linkage of information provided by public health laboratories to the selection of relevant, appropriate and effective public health responses to disease outbreaks. Methods We reviewed the development of Rwanda's National Reference Laboratory (NRL) to understand essential structures involved in creating a national public health laboratory network. We reviewed documents describing the NRL's organization and record of test results, conducted site visits, and interviewed health staff in the Ministry of Health and in partner agencies. Findings were developed by organizing thematic categories and grouping examples within them. We purposefully sought to identify success factors as well as challenges inherent in developing a national public health laboratory system. Results Among the identified success factors were: a structured governing framework for public health surveillance; political commitment to promote leadership for stronger laboratory capacities in Rwanda; defined roles and responsibilities for each level; coordinated approaches between technical and funding partners; collaboration with external laboratories; and use of performance results in advocacy with national stakeholders. Major challenges involved general infrastructure, human resources, and budgetary constraints. Conclusions Rwanda's experience with collaborative partnerships contributed to creation of a functional public health laboratory network. PMID:21702948
RENEB accident simulation exercise.
Brzozowska, Beata; Ainsbury, Elizabeth; Baert, Annelot; Beaton-Green, Lindsay; Barrios, Leonardo; Barquinero, Joan Francesc; Bassinet, Celine; Beinke, Christina; Benedek, Anett; Beukes, Philip; Bortolin, Emanuela; Buraczewska, Iwona; Burbidge, Christopher; De Amicis, Andrea; De Angelis, Cinzia; Della Monaca, Sara; Depuydt, Julie; De Sanctis, Stefania; Dobos, Katalin; Domene, Mercedes Moreno; Domínguez, Inmaculada; Facco, Eva; Fattibene, Paola; Frenzel, Monika; Monteiro Gil, Octávia; Gonon, Géraldine; Gregoire, Eric; Gruel, Gaëtan; Hadjidekova, Valeria; Hatzi, Vasiliki I; Hristova, Rositsa; Jaworska, Alicja; Kis, Enikő; Kowalska, Maria; Kulka, Ulrike; Lista, Florigio; Lumniczky, Katalin; Martínez-López, Wilner; Meschini, Roberta; Moertl, Simone; Moquet, Jayne; Noditi, Mihaela; Oestreicher, Ursula; Orta Vázquez, Manuel Luis; Palma, Valentina; Pantelias, Gabriel; Montoro Pastor, Alegria; Patrono, Clarice; Piqueret-Stephan, Laure; Quattrini, Maria Cristina; Regalbuto, Elisa; Ricoul, Michelle; Roch-Lefevre, Sandrine; Roy, Laurence; Sabatier, Laure; Sarchiapone, Lucia; Sebastià, Natividad; Sommer, Sylwester; Sun, Mingzhu; Suto, Yumiko; Terzoudi, Georgia; Trompier, Francois; Vral, Anne; Wilkins, Ruth; Zafiropoulos, Demetre; Wieser, Albrecht; Woda, Clemens; Wojcik, Andrzej
2017-01-01
The RENEB accident exercise was carried out in order to train the RENEB participants in coordinating and managing potentially large data sets that would be generated in case of a major radiological event. Each participant was offered the possibility to activate the network by sending an alerting email about a simulated radiation emergency. The same participant had to collect, compile and report capacity, triage categorization and exposure scenario results obtained from all other participants. The exercise was performed over 27 weeks and involved the network consisting of 28 institutes: 21 RENEB members, four candidates and three non-RENEB partners. The duration of a single exercise never exceeded 10 days, while the response from the assisting laboratories never came later than within half a day. During each week of the exercise, around 4500 samples were reported by all service laboratories (SL) to be examined and 54 scenarios were coherently estimated by all laboratories (the standard deviation from the mean of all SL answers for a given scenario category and a set of data was not larger than 3 patient codes). Each participant received training in both the role of a reference laboratory (activating the network) and of a service laboratory (responding to an activation request). The procedures in the case of radiological event were successfully established and tested.
Data collected between January to December, 1999 were polled from the USEPA Aerometric Information Retrieval System. For the purpose of this analysis, data which were flagged with qualifiers related to laboratory and monitor malfunctions were removed from the data set. Analys...
Ciabatti, I; Marchesi, U; Froiio, A; Paternò, A; Ruggeri, M; Amaddeo, D
2005-08-01
The National Reference Centre for Genetically Modified Organisms (GMO) detection was established in 2002 within the Istituto Zooprofilattico Sperimentale Lazio e Toscana, with the aim of providing scientific and technical support to the National Health System and to the Ministry of Health within the scope of the regulation of GMO use in food and feed.The recently adopted EU legislation on GMOs (Regulation CE no. 1829/2003 and no. 1830/2003) introduced more rigorous procedures for the authorisation, labelling and analytical control of food and feed consisting, containing or derived from GMOs. The National Reference Centre, besides its institutional tasks as one of the laboratories of the Italian National Health System, collects and analyses data and results of the national official control of GMOs; carries out scientific research aimed at developing, improving, validating and harmonising detection and quantification methods, in cooperation with other scientific institutions, the Community Reference Laboratory and within the European Network of GMOs laboratories (ENGL); collaborates with the Ministry of Health in the definition of control programmes and promotes educational and training initiatives. Objectives defined for 2004-2006, activities in progress and goals already achieved are presented.
Brooks, M.H.; Schroder, L.J.; Willoughby, T.C.
1987-01-01
The U.S. Geological Survey operated a blind audit sample program during 1974 to test the effects of the sample handling and shipping procedures used by the National Atmospheric Deposition Program and National Trends Network on the quality of wet deposition data produced by the combined networks. Blind audit samples, which were dilutions of standard reference water samples, were submitted by network site operators to the central analytical laboratory disguised as actual wet deposition samples. Results from the analyses of blind audit samples were used to calculate estimates of analyte bias associated with all network wet deposition samples analyzed in 1984 and to estimate analyte precision. Concentration differences between double blind samples that were submitted to the central analytical laboratory and separate analyses of aliquots of those blind audit samples that had not undergone network sample handling and shipping were used to calculate analyte masses that apparently were added to each blind audit sample by routine network handling and shipping procedures. These calculated masses indicated statistically significant biases for magnesium, sodium , potassium, chloride, and sulfate. Median calculated masses were 41.4 micrograms (ug) for calcium, 14.9 ug for magnesium, 23.3 ug for sodium, 0.7 ug for potassium, 16.5 ug for chloride and 55.3 ug for sulfate. Analyte precision was estimated using two different sets of replicate measures performed by the central analytical laboratory. Estimated standard deviations were similar to those previously reported. (Author 's abstract)
End-User Searching in a Large Library Network: A Case Study of Patent Attorneys.
ERIC Educational Resources Information Center
Vollaro, Alice J.; Hawkins, Donald T.
1986-01-01
Reports results of study of a group of end users (patent attorneys) doing their own online searching at AT&T Bell Laboratories. Highlights include DIALOG databases used by the attorneys, locations and searching modes, characteristics of patent attorney searchers, and problem areas. Questionnaire is appended. (5 references) (EJS)
ERIC Educational Resources Information Center
Deng, Yi-Chan; Lin, Taiyu; Kinshuk; Chan, Tak-Wai
2006-01-01
"One-to-one" technology enhanced learning research refers to the design and investigation of learning environments and learning activities where every learner is equipped with at least one portable computing device enabled by wireless capability. G1:1 is an international research community coordinated by a network of laboratories conducting…
EDRN Biomarker Reference Lab: Pacific Northwest National Laboratory — EDRN Public Portal
The purpose of this project is to develop antibody microarrays incorporating three major improvements compared to previous antibody microarray platforms, and to produce and disseminate these antibody microarray technologies for the Early Detection Research Network (EDRN) and the research community focusing on early detection, and risk assessment of cancer.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Owens, J; Koester, C
The Environmental Protection Agency's (EPA) Region 5 Chicago Regional Laboratory (CRL) developed a method for analysis of aldicarb, bromadiolone, carbofuran, oxamyl, and methomyl in water by high performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS), titled Method EPA MS666. This draft standard operating procedure (SOP) was distributed to multiple EPA laboratories and to Lawrence Livermore National Laboratory, which was tasked to serve as a reference laboratory for EPA's Environmental Reference Laboratory Network (ERLN) and to develop and validate analytical procedures. The primary objective of this study was to validate and verify the analytical procedures described in MS666 for analysis of carbamatemore » pesticides in aqueous samples. The gathered data from this validation study will be used to: (1) demonstrate analytical method performance; (2) generate quality control acceptance criteria; and (3) revise the SOP to provide a validated method that would be available for use during a homeland security event. The data contained in this report will be compiled, by EPA CRL, with data generated by other EPA Regional laboratories so that performance metrics of Method EPA MS666 can be determined.« less
Analysis of Ethanolamines: Validation of Semi-Volatile Analysis by HPLC-MS/MS by EPA Method MS888
DOE Office of Scientific and Technical Information (OSTI.GOV)
Owens, J; Vu, A; Koester, C
The Environmental Protection Agency's (EPA) Region 5 Chicago Regional Laboratory (CRL) developed a method titled 'Analysis of Diethanolamine, Triethanolamine, n-Methyldiethanolamine, and n-Ethyldiethanolamine in Water by Single Reaction Monitoring Liquid Chromatography/Tandem Mass Spectrometry (LC/MS/MS): EPA Method MS888'. This draft standard operating procedure (SOP) was distributed to multiple EPA laboratories and to Lawrence Livermore National Laboratory, which was tasked to serve as a reference laboratory for EPA's Environmental Reference Laboratory Network (ERLN) and to develop and validate analytical procedures. The primary objective of this study was to validate and verify the analytical procedures described in 'EPA Method MS888' for analysis of themore » listed ethanolamines in aqueous samples. The gathered data from this validation study will be used to: (1) demonstrate analytical method performance; (2) generate quality control acceptance criteria; and (3) revise the SOP to provide a validated method that would be available for use during a homeland security event. The data contained in this report will be compiled, by EPA CRL, with data generated by other EPA Regional laboratories so that performance metrics of 'EPA Method MS888' can be determined.« less
[Microbiological Surveillance of Measles and Rubella in Spain. Laboratory Network].
Echevarría, Juan Emilio; Fernández García, Aurora; de Ory, Fernando
2015-01-01
The Laboratory is a fundamental component on the surveillance of measles and rubella. Cases need to be properly confirmed to ensure an accurate estimation of the incidence. Strains should be genetically characterized to know the transmission pattern of these viruses and frequently, outbreaks and transmission chains can be totally discriminated only after that. Finally, the susceptibility of the population is estimated on the basis of sero-prevalence surveys. Detection of specific IgM response is the base of the laboratory diagnosis of these diseases. It should be completed with genomic detection by RT-PCR to reach an optimal efficiency, especially when sampling is performed early in the course of the disease. Genotyping is performed by genomic sequencing according to reference protocols of the WHO. Laboratory surveillance of measles and rubella in Spain is organized as a net of regional laboratories with different capabilities. The National Center of Microbiology as National Reference Laboratory (NRL), supports regional laboratories ensuring the availability of all required techniques in the whole country and watching for the quality of the results. The NRL is currently working in the implementation of new molecular techniques based on the analysis of genomic hypervariable regions for the strain characterization at sub-genotypic levels and use them in the surveillance.
Establishment of National Laboratory Standards in Public and Private Hospital Laboratories
ANJARANI, Soghra; SAFADEL, Nooshafarin; DAHIM, Parisa; AMINI, Rana; MAHDAVI, Saeed; MIRAB SAMIEE, Siamak
2013-01-01
In September 2007 national standard manual was finalized and officially announced as the minimal quality requirements for all medical laboratories in the country. Apart from auditing laboratories, Reference Health Laboratory has performed benchmarking auditing of medical laboratory network (surveys) in provinces. 12th benchmarks performed in Tehran and Alborz provinces, Iran in 2010 in three stages. We tried to compare different processes, their quality and accordance with national standard measures between public and private hospital laboratories. The assessment tool was a standardized checklist consists of 164 questions. Analyzing process show although in most cases implementing the standard requirements are more prominent in private laboratories, there is still a long way to complete fulfillment of requirements, and it takes a lot of effort. Differences between laboratories in public and private sectors especially in laboratory personnel and management process are significant. Probably lack of motivation, plays a key role in obtaining less desirable results in laboratories in public sectors. PMID:23514840
Ring trial 2016 for Bluetongue virus detection by real-time RT-PCR in France.
Sailleau, Corinne; Viarouge, Cyril; Breard, Emmanuel; Vitour, Damien; Zientara, Stephan
2017-05-01
Since the unexpected emergence of BTV-8 in Northern Europe and the incursion of BTV-8 and 1 in France in 2006-2007, molecular diagnosis has considerably evolved. Several real-time RT-PCR (rtRT-PCR) methods have been developed and published, and are currently being used in many countries across Europe for BTV detection and typing. In France, the national reference laboratory (NRL) for orbiviruses develops and validates 'ready-to-use' kits with private companies for viral RNA detection. The regional laboratories network that was set up to deal with a heavy demand for analyses has used these available kits. From 2007, ring tests were organized to monitor the performance of the French laboratories. This study presents the results of 63 regional laboratories in the ring trial organized in 2016. Blood samples were sent to the laboratories. Participants were asked to use the rtRT-PCR methods in place in their laboratory, for detection of all BTV serotypes and specifically BTV-8. The French regional laboratories are able to detect and genotype BTV in affected animals. Despite the use of several methods (i.e. RNA extraction and different commercial rtRT-PCRs), the network is homogeneous. The ring trial demonstrated that the French regional veterinary laboratories have reliable and robust BTV diagnostic tools for BTV genome detection.
Lucey, K.J.
1990-01-01
The U.S. Geological Survey conducts an external blind sample quality assurance project for its National Water Quality Laboratory in Denver, Colorado, based on the analysis of reference water samples. Reference samples containing selected inorganic and nutrient constituents are disguised as environmental samples at the Survey 's office in Ocala, Florida, and are sent periodically through other Survey offices to the laboratory. The results of this blind sample project indicate the quality of analytical data produced by the laboratory. This report provides instructions on the use of QADATA, an interactive, menu-driven program that allows users to retrieve the results of the blind sample quality- assurance project. The QADATA program, which is available on the U.S. Geological Survey 's national computer network, accesses a blind sample data base that contains more than 50,000 determinations from the last five water years for approximately 40 constituents at various concentrations. The data can be retrieved from the database for any user- defined time period and for any or all available constituents. After the user defines the retrieval, the program prepares statistical tables, control charts, and precision plots and generates a report which can be transferred to the user 's office through the computer network. A discussion of the interpretation of the program output is also included. This quality assurance information will permit users to document the quality of the analytical results received from the laboratory. The blind sample data is entered into the database within weeks after being produced by the laboratory and can be retrieved to meet the needs of specific projects or programs. (USGS)
Rosin, P; Niskanen, T; Palm, D; Struelens, M; Takkinen, J
2013-06-20
A hybrid strain of enteroaggregative and Shiga toxin 2-producing Escherichia coli (EAEC-STEC) serotype O104:H4 strain caused a large outbreak of haemolytic uraemic syndrome and bloody diarrhoea in 2011 in Europe. Two surveys were performed in the European Union (EU) and European Economic Area (EEA) countries to assess their laboratory capabilities to detect and characterise this previously uncommon STEC strain. Prior to the outbreak, 11 of the 32 countries in this survey had capacity at national reference laboratory (NRL) level for epidemic case confirmation according to the EU definition. During the outbreak, at primary diagnostic level, nine countries reported that clinical microbiology laboratories routinely used Shiga toxin detection assays suitable for diagnosis of infections with EAEC-STEC O104:H4, while 14 countries had NRL capacity to confirm epidemic cases. Six months after the outbreak, 22 countries reported NRL capacity to confirm such cases following initiatives taken by NRLs and the European Centre for Disease Prevention and Control (ECDC) Food- and Waterborne Disease and Zoonoses laboratory network. These data highlight the challenge of detection and confirmation of epidemic infections caused by atypical STEC strains and the benefits of coordinated EU laboratory networks to strengthen capabilities in response to a major outbreak.
Huet, Sylvie; Marie, Jean-Pierre; Laurand, Armelle; Robert, Jacques
2005-09-01
The aim of this study was to improve significantly the sensitivity and specificity of the flow cytometric assay of P-glycoprotein (Pgp) implemented and validated by the laboratories of the French Drug Resistance Network [Huet S, Marie JP, Gualde N, Robert J. Reference method for detection of Pgp mediated multidrug resistance in human hematological malignancies: a method validated by the laboratories of the French Drug Resistance Network. Cytometry 1998;34:248-56] in cells displaying low level of resistance. Fluoresceine-conjugated monoclonal antibodies (Mabs) and propidium iodide were respectively replaced by phycoerythrin-conjugated Mabs and Sytox green. The removal of erythrocytes and granulocytes by density gradient was replaced by the lysis of erythrocytes after Mab incubation. Using these conditions, Pgp could be detected in the K-H30 line, which was negative in former studies, with Mab/Control ratios increasing by 3.7- to 5.9-fold, and Mab/Control ratios in the parental sensitive K562 line still ranging between 0.8 and 1.2. When tested on 16 blood samples from patients presenting haematological malignancies, six samples presented low positivity, which was not detected with the former method, while 10 samples remained negative with the two methods. Pgp was specifically detected in pathological blood cells in the six positive samples.
von Holst, Christoph; Robouch, Piotr; Bellorini, Stefano; de la Huebra, María José González; Ezerskis, Zigmas
2016-01-01
ABSTRACT This paper describes the operation of the European Union Reference Laboratory for Feed Additives (EURL) and its role in the authorisation procedure of feed additives in the European Union. Feed additives are authorised according to Regulation (EC) No. 1831/2003, which introduced a completely revised authorisation procedure and also established the EURL. The regulations authorising feed additives contain conditions of use such as legal limits of the feed additives, which require the availability of a suitable method of analysis for official control purposes under real world conditions. It is the task of the EURL to evaluate the suitability of analytical methods as proposed by the industry for this purpose. Moreover, the paper shows that one of the major challenges is the huge variety of the methodology applied in feed additive analysis, thus requiring expertise in quite different analytical areas. In order to cope with this challenge, the EURL is supported by a network of national reference laboratories (NRLs) and only the merged knowledge of all NRLs allows for a scientifically sound assessment of the analytical methods. PMID:26540604
The role of diagnostic laboratories in support of animal disease surveillance systems.
Zepeda, C
2007-01-01
Diagnostic laboratories are an essential component of animal disease surveillance systems. To understand the occurrence of disease in populations, surveillance systems rely on random or targeted surveys using three approaches: clinical, serological and virological surveillance. Clinical surveillance is the basis for early detection of disease and is usually centered on the detection of syndromes and clinical findings requiring confirmation by diagnostic laboratories. Although most of the tests applied usually perform to an acceptable standard, several have not been properly validated in terms of their diagnostic sensitivity and specificity. Sensitivity and specificity estimates can vary according to local conditions and, ideally, should be determined by national laboratories where the tests are to be applied. The importance of sensitivity and specificity estimates in the design and interpretation of statistically based surveys and risk analysis is fundamental to establish appropriate disease control and prevention strategies. The World Organisation for Animal Health's (OIE) network of reference laboratories acts as centers of expertise for the diagnosis of OIE listed diseases and have a role in promoting the validation of OIE prescribed tests for international trade. This paper discusses the importance of the epidemiological evaluation of diagnostic tests and the role of the OIE Reference Laboratories and Collaborating Centres in this process.
Analysis of Phosphonic Acids: Validation of Semi-Volatile Analysis by HPLC-MS/MS by EPA Method MS999
DOE Office of Scientific and Technical Information (OSTI.GOV)
Owens, J; Vu, A; Koester, C
The Environmental Protection Agency's (EPA) Region 5 Chicago Regional Laboratory (CRL) developed a method titled Analysis of Diisopropyl Methylphosphonate, Ethyl Hydrogen Dimethylamidophosphate, Isopropyl Methylphosphonic Acid, Methylphosphonic Acid, and Pinacolyl Methylphosphonic Acid in Water by Multiple Reaction Monitoring Liquid Chromatography/Tandem Mass Spectrometry: EPA Version MS999. This draft standard operating procedure (SOP) was distributed to multiple EPA laboratories and to Lawrence Livermore National Laboratory, which was tasked to serve as a reference laboratory for EPA's Environmental Reference Laboratory Network (ERLN) and to develop and validate analytical procedures. The primary objective of this study was to validate and verify the analytical procedures describedmore » in EPA Method MS999 for analysis of the listed phosphonic acids and surrogates in aqueous samples. The gathered data from this validation study will be used to: (1) demonstrate analytical method performance; (2) generate quality control acceptance criteria; and (3) revise the SOP to provide a validated method that would be available for use during a homeland security event. The data contained in this report will be compiled, by EPA CRL, with data generated by other EPA Regional laboratories so that performance metrics of EPA Method MS999 can be determined.« less
Promoting, building and sustaining a regional laboratory network in a changing environment.
More, J D; Sengupta, S K; Manley, P N
2000-01-01
The Queen's University Department of Pathology and its affiliated hospital laboratories (Kingston, Canada) have operated a successful laboratory outreach program for more than a decade in Southeastern Ontario. The outreach program provides high quality reference testing and technical and professional expertise in laboratory medicine to largely rural and small urban community hospitals. As a consequence of dramatic cuts to the publicly funded health-care system in the Province of Ontario, the environment in which laboratory medicine is practiced has altered irrevocably. This article discusses some of the difficult internal and external challenges faced by the outreach program within the region and how they were effectively managed, not only to maintain but to enhance the program's services. The result has been a continued improvement in the quality of laboratory services in the region with significantly increased cost-effectiveness, largely through reengineering and consolidation.
The International GPS Network for Charting the Evolving Global Reference Frame
NASA Technical Reports Server (NTRS)
Zumberge, J. F.; Heflin, M. B.; Lindqwister, U. J.; Neilan, R. E.; Watkins, M. M.
1995-01-01
The Telecommunications and Engineering Division of Caltech's Jet Propulsion Laboratory is funded by the National Aeronautics and Space Administration to play a variety of roles in applying the Global Positioning System (GPS) to geodesy and geodynamics. Among these are the operation of dozens of globally-distributed, permanently-operating Earth fixed GPS stations. This, and other applications are described.
ERIC Educational Resources Information Center
Hill, Roberta; Capper, Phillip; Wilson, Ken; Whatman, Richard; Wong, Karen
2007-01-01
Purpose: The purpose of this paper is to describe how, from 2004-2006, a New Zealand research team experimented with the "change laboratory" learning process to create a new method of government policy development and implementation, referred to as "practice-making". The apple industry in Hawke's Bay was chosen because of the…
Lenters-Westra, Erna; English, Emma
2017-08-28
As a reference laboratory for HbA1c, it is essential to have accurate and precise HbA1c methods covering a range of measurement principles. We report an evaluation of the Abbott Enzymatic (Architect c4000), Roche Gen.3 HbA1c (Cobas c513) and Tosoh G11 using different quality targets. The effect of hemoglobin variants, other potential interferences and the performance in comparison to both the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) and the National Glycohemoglobin Standardization Program (NGSP) reference systems was assessed using certified evaluation protocols. Each of the evaluated HbA1c methods had CVs <3% in SI units and <2% in NGSP units at 46 mmol/mol (6.4%) and 72 mmol/mol (8.7%) and passed the NGSP criteria when compared with six secondary reference measurement procedures (SRMPs). Sigma was 8.6 for Abbott Enzymatic, 3.3 for Roche Cobas c513 and 6.9 for Tosoh G11. No clinically significant interference was detected for the common Hb variants for the three methods. All three methods performed well and are suitable for clinical application in the analysis of HbA1c. Partly based on the result of this study, the Abbott Enzymatic method on the Architect c4000 and the Roche Gen.3 HbA1c on the Cobas c513 are now official, certified IFCC and NGSP SRMPs in the IFCC and NGSP networks. Sigma metrics quality criteria presented in a graph distinguish between good and excellent performance.
Developing laboratory networks: a practical guide and application.
Kirk, Carol J; Shult, Peter A
2010-01-01
The role of the public health laboratory (PHL) in support of public health response has expanded beyond testing to include a number of other core functions, such as emergency response, training and outreach, communications, laboratory-based surveillance, and laboratory data management. These functions can only be accomplished by a network that includes public health and other agency laboratories and clinical laboratories. It is a primary responsibility of the PHL to develop and maintain such a network. In this article, we present practical recommendations-based on 17 years of network development experience-for the development of statewide laboratory networks. These recommendations, and examples of current laboratory networks, are provided to facilitate laboratory network development in other states. The development of laboratory networks will enhance each state's public health system and is critical to the development of a robust national Laboratory Response Network.
Hunsperger, Elizabeth A.; Yoksan, Sutee; Buchy, Philippe; Nguyen, Vinh Chau; Sekaran, Shamala Devi; Enria, Delia A.; Vazquez, Susana; Cartozian, Elizabeth; Pelegrino, Jose L.; Artsob, Harvey; Guzman, Maria G.; Olliaro, Piero; Zwang, Julien; Guillerm, Martine; Kliks, Susie; Halstead, Scott; Peeling, Rosanna W.; Margolis, Harold S.
2014-01-01
Commercially available diagnostic test kits for detection of dengue virus (DENV) non-structural protein 1 (NS1) and anti-DENV IgM were evaluated for their sensitivity and specificity and other performance characteristics by a diagnostic laboratory network developed by World Health Organization (WHO), the UNICEF/UNDP/World Bank/WHO Special Programme for Research and Training in Tropical Diseases (TDR) and the Pediatric Dengue Vaccine Initiative (PDVI). Each network laboratory contributed characterized serum specimens for the panels used in the evaluation. Microplate enzyme-linked immunosorbent assay (ELISA) and rapid diagnostic test (RDT formats) were represented by the kits. Each ELISA was evaluated by 2 laboratories and RDTs were evaluated by at least 3 laboratories. The reference tests for IgM anti-DENV were laboratory developed assays produced by the Armed Forces Research Institute for Medical Science (AFRIMS) and the Centers for Disease Control and Prevention (CDC), and the NS1 reference test was reverse transcriptase polymerase chain reaction (RT-PCR). Results were analyzed to determine sensitivity, specificity, inter-laboratory and inter-reader agreement, lot-to-lot variation and ease-of-use. NS1 ELISA sensitivity was 60–75% and specificity 71–80%; NS1 RDT sensitivity was 38–71% and specificity 76–80%; the IgM anti-DENV RDTs sensitivity was 30–96%, with a specificity of 86–92%, and IgM anti-DENV ELISA sensitivity was 96–98% and specificity 78–91%. NS1 tests were generally more sensitive in specimens from the acute phase of dengue and in primary DENV infection, whereas IgM anti-DENV tests were less sensitive in secondary DENV infections. The reproducibility of the NS1 RDTs ranged from 92-99% and the IgM anti-DENV RDTs from 88–94%. PMID:25330157
Compilation of Earthquakes from 1850-2007 within 200 miles of the Idaho National Laboratory
DOE Office of Scientific and Technical Information (OSTI.GOV)
N. Seth Carpenter
2010-07-01
An updated earthquake compilation was created for the years 1850 through 2007 within 200 miles of the Idaho National Laboratory. To generate this compilation, earthquake catalogs were collected from several contributing sources and searched for redundant events using the search criteria established for this effort. For all sets of duplicate events, a preferred event was selected, largely based on epicenter-network proximity. All unique magnitude information for each event was added to the preferred event records and these records were used to create the compilation referred to as “INL1850-2007”.
Laboratory testing under managed care dominance in the USA
Takemura, Y; Beck, J
2001-01-01
The uncontrolled escalation of total health care expenditure despite the government's endeavours during the past decades in the USA had led to the rapid infiltration of managed care organisations (MCOs). Traditional hospital based laboratories have been placed in a crucial situation with the advent of the managed care era. A massive reduction of in house testing urged them to develop strategies against financial difficulty. Consolidation and networking, participation in the outreach testing market, and emphasis on point of care/satellite laboratory testing in non-traditional, ambulatory settings are major strategies for the survival of hospital laboratories. Several physicians' office laboratories (POLS) have closed their doors in response both to regulatory restrictions imposed by the Clinical Laboratory Improvement Amendments of 1988 and to managed care infiltration. It seems likely that POLs and hospital laboratories will continue to reduce test volumes, whereas commercial reference laboratories will thrive through contracting with MCOs. In the current climate of managed care dominance in the USA, clinical laboratories are changing their basic operation focus and mission in response to the aggressively changing landscape. Key Words: laboratory testing • managed care organisations • survival strategies PMID:11215291
Grunow, Roland; Ippolito, G; Jacob, D; Sauer, U; Rohleder, A; Di Caro, A; Iacovino, R
2014-01-01
Quality assurance exercises and networking on the detection of highly infectious pathogens (QUANDHIP) is a joint action initiative set up in 2011 that has successfully unified the primary objectives of the European Network on Highly Pathogenic Bacteria (ENHPB) and of P4-laboratories (ENP4-Lab) both of which aimed to improve the efficiency, effectiveness, and response capabilities of laboratories directed at protecting the health of European citizens against high consequence bacteria and viruses of significant public health concern. Both networks have established a common collaborative consortium of 37 nationally and internationally recognized institutions with laboratory facilities from 22 European countries. The specific objectives and achievements include the initiation and establishment of a recognized and acceptable quality assurance scheme, including practical external quality assurance exercises, comprising living agents, that aims to improve laboratory performance, accuracy, and detection capabilities in support of patient management and public health responses; recognized training schemes for diagnostics and handling of highly pathogenic agents; international repositories comprising highly pathogenic bacteria and viruses for the development of standardized reference material; a standardized and transparent Biosafety and Biosecurity strategy protecting healthcare personnel and the community in dealing with high consequence pathogens; the design and organization of response capabilities dealing with cross-border events with highly infectious pathogens including the consideration of diagnostic capabilities of individual European laboratories. The project tackled several sensitive issues regarding Biosafety, Biosecurity and "dual use" concerns. The article will give an overview of the project outcomes and discuss the assessment of potential "dual use" issues.
Grunow, Roland; Ippolito, G.; Jacob, D.; Sauer, U.; Rohleder, A.; Di Caro, A.; Iacovino, R.
2014-01-01
Quality assurance exercises and networking on the detection of highly infectious pathogens (QUANDHIP) is a joint action initiative set up in 2011 that has successfully unified the primary objectives of the European Network on Highly Pathogenic Bacteria (ENHPB) and of P4-laboratories (ENP4-Lab) both of which aimed to improve the efficiency, effectiveness, and response capabilities of laboratories directed at protecting the health of European citizens against high consequence bacteria and viruses of significant public health concern. Both networks have established a common collaborative consortium of 37 nationally and internationally recognized institutions with laboratory facilities from 22 European countries. The specific objectives and achievements include the initiation and establishment of a recognized and acceptable quality assurance scheme, including practical external quality assurance exercises, comprising living agents, that aims to improve laboratory performance, accuracy, and detection capabilities in support of patient management and public health responses; recognized training schemes for diagnostics and handling of highly pathogenic agents; international repositories comprising highly pathogenic bacteria and viruses for the development of standardized reference material; a standardized and transparent Biosafety and Biosecurity strategy protecting healthcare personnel and the community in dealing with high consequence pathogens; the design and organization of response capabilities dealing with cross-border events with highly infectious pathogens including the consideration of diagnostic capabilities of individual European laboratories. The project tackled several sensitive issues regarding Biosafety, Biosecurity and “dual use” concerns. The article will give an overview of the project outcomes and discuss the assessment of potential “dual use” issues. PMID:25426479
Analysis of power management and system latency in wireless sensor networks
NASA Astrophysics Data System (ADS)
Oswald, Matthew T.; Rohwer, Judd A.; Forman, Michael A.
2004-08-01
Successful power management in a wireless sensor network requires optimization of the protocols which affect energy-consumption on each node and the aggregate effects across the larger network. System optimization for a given deployment scenario requires an analysis and trade off of desired node and network features with their associated costs. The sleep protocol for an energy-efficient wireless sensor network for event detection, target classification, and target tracking developed at Sandia National Laboratories is presented. The dynamic source routing (DSR) algorithm is chosen to reduce network maintenance overhead, while providing a self-configuring and self-healing network architecture. A method for determining the optimal sleep time is developed and presented, providing reference data which spans several orders of magnitude. Message timing diagrams show, that a node in a five-node cluster, employing an optimal cyclic single-radio sleep protocol, consumes 3% more energy and incurs a 16-s increase latency than nodes employing the more complex dual-radio STEM protocol.
Ben Jebara, K
2010-12-01
One of the main objectives of the World Organisation for Animal Health (OIE) is to ensure transparency in and knowledge of the world animal health situation. To achieve this objective, the OIE relies on its network of Member Countries, which is complemented by the activities of 221 Reference Laboratories (RLs) and Collaborating Centres. The RL mandate states that, in the case of positive results for diseases notifiable to the OIE, the laboratory should inform the OIE Delegate of the Member Country from which the samples originated and send a copy of the information to OIE Headquarters. However, since 2006 the OIE has received a lower than expected number of notifications from RLs, which implies eitherthat the majority of samples are sent to national laboratories or that some RLs are not fully complying with their mandate. The OIE sent a questionnaire to RLs in preparation for the Second Global Conference of OIE Reference Laboratories and Collaborating Centres (Paris, France, 21-23 June 2010). Two main factors emerged: the need for RLs to clarify their role and responsibilities in disease reporting and the need for an awareness campaign to sensitise national Veterinary Services to the importance of conducting more surveillance (and consequently of submitting samples to RLs) for all OIE-listed diseases. Reference laboratories indicated two main reasons for not sharing more data on positive samples with the OIE: i) a perceived contradiction between their mandate as OIE RLs and the standards of the International Organization for Standardization (ISO) dealing with confidentiality; and ii) certain Member Countries or stakeholders asking RLs not to share positive results with the OIE, for political or economic reasons. The OIE has put forward proposals to help RLs resolve these problems in future. The use of ISO standards must be clarified and there must be improved communication between the OIE and its RLs. A lack of transparency about a significant disease event can jeopardise the biosecurity of several countries, an entire region or even the whole world. The reference status of a non-transparent RL could be questioned.
Relova, Damarys; Acevedo, Ana M.; Coronado, Liani; Perera, Carmen L.
2018-01-01
The current global conditions, which include intensive globalization, climate changes, and viral evolution among other factors, have led to an increased emergence of viruses and new viral diseases; RNA viruses are key drivers of this evolution. Laboratory networks that are linked to central reference laboratories are required to conduct both active and passive environmental surveillance of this complicated global viral environment. These tasks require a continuous exchange of strains or field samples between different diagnostic laboratories. The shipment of these samples on dry ice represents both a biological hazard and a general health risk. Moreover, the requirement to ship on dry ice could be hampered by high costs, particularly in underdeveloped countries or regions located far from each other. To solve these issues, the shipment of RNA isolated from viral suspensions or directly from field samples could be a useful way to share viral genetic material. However, extracted RNA stored in aqueous solutions, even at −70 °C, is highly prone to degradation. The current study evaluated different RNA storage conditions for safety and feasibility for future use in molecular diagnostics. The in vitro RNA-transcripts obtained from an inactivated highly pathogenic avian influenza (HPAI) H5N1 virus was used as a model. The role of secondary structures in the protection of the RNA was also explored. Of the conditions evaluated, the dry pellet matrix was best able to protect viral RNA under extreme storage conditions. This method is safe, cost-effective and assures the integrity of RNA samples for reliable molecular diagnosis. This study aligns with the globally significant “Global One Health” paradigm, especially with respect to the diagnosis of emerging diseases that require confirmation by reference laboratories. PMID:29415432
Cascaded multiplexed optical link on a telecommunication network for frequency dissemination.
Lopez, Olivier; Haboucha, Adil; Kéfélian, Fabien; Jiang, Haifeng; Chanteau, Bruno; Roncin, Vincent; Chardonnet, Christian; Amy-Klein, Anne; Santarelli, Giorgio
2010-08-02
We demonstrate a cascaded optical link for ultrastable frequency dissemination comprised of two compensated links of 150 km and a repeater station. Each link includes 114 km of Internet fiber simultaneously carrying data traffic through a dense wavelength division multiplexing technology, and passes through two routing centers of the telecommunication network. The optical reference signal is inserted in and extracted from the communication network using bidirectional optical add-drop multiplexers. The repeater station operates autonomously ensuring noise compensation on the two links and the ultra-stable signal optical regeneration. The compensated link shows a fractional frequency instability of 3 x 10(-15) at one second measurement time and 5 x 10(-20) at 20 hours. This work paves the way to a wide dissemination of ultra-stable optical clock signals between distant laboratories via the Internet network.
Broberg, E; Pereyaslov, D; Struelens, M; Palm, D; Meijer, A; Ellis, J; Zambon, M; McCauley, J; Daniels, R
2015-01-01
Following human infections with novel avian influenza A(H7N9) viruses in China, the European Centre for Disease Prevention and Control, the World Health Organization (WHO) Regional Office for Europe and the European Reference Laboratory Network for Human Influenza (ERLI-Net) rapidly posted relevant information, including real-time RT-PCR protocols. An influenza RNA sequence-based computational assessment of detection capabilities for this virus was conducted in 32 national influenza reference laboratories in 29 countries, mostly WHO National Influenza Centres participating in the WHO Global Influenza Surveillance and Response System (GISRS). Twenty-seven countries considered their generic influenza A virus detection assay to be appropriate for the novel A(H7N9) viruses. Twenty-two countries reported having containment facilities suitable for its isolation and propagation. Laboratories in 27 countries had applied specific H7 real-time RT-PCR assays and 20 countries had N9 assays in place. Positive control virus RNA was provided by the WHO Collaborating Centre in London to 34 laboratories in 22 countries to allow evaluation of their assays. Performance of the generic influenza A virus detection and H7 and N9 subtyping assays was good in 24 laboratories in 19 countries. The survey showed that ERLI-Net laboratories had rapidly developed and verified good capability to detect the novel A(H7N9) influenza viruses. PMID:24507469
Study of the GPS inter-frequency calibration of timing receivers
NASA Astrophysics Data System (ADS)
Defraigne, P.; Huang, W.; Bertrand, B.; Rovera, D.
2018-02-01
When calibrating Global Positioning System (GPS) stations dedicated to timing, the hardware delays of P1 and P2, the P(Y)-codes on frequencies L1 and L2, are determined separately. In the international atomic time (TAI) network the GPS stations of the time laboratories are calibrated relatively against reference stations. This paper aims at determining the consistency between the P1 and P2 hardware delays (called dP1 and dP2) of these reference stations, and to look at the stability of the inter-signal hardware delays dP1-dP2 of all the stations in the network. The method consists of determining the dP1-dP2 directly from the GPS pseudorange measurements corrected for the frequency-dependent antenna phase center and the frequency-dependent ionosphere corrections, and then to compare these computed dP1-dP2 to the calibrated values. Our results show that the differences between the computed and calibrated dP1-dP2 are well inside the expected combined uncertainty of the two quantities. Furthermore, the consistency between the calibrated time transfer solution obtained from either single-frequency P1 or dual-frequency P3 for reference laboratories is shown to be about 1.0 ns, well inside the 2.1 ns uB uncertainty of a time transfer link based on GPS P3 or Precise Point Positioning. This demonstrates the good consistency between the P1 and P2 hardware delays of the reference stations used for calibration in the TAI network. The long-term stability of the inter-signal hardware delays is also analysed from the computed dP1-dP2. It is shown that only variations larger than 2 ns can be detected for a particular station, while variations of 200 ps can be detected when differentiating the results between two stations. Finally, we also show that in the differential calibration process as used in the TAI network, using the same antenna phase center or using different positions for L1 and L2 signals gives maximum differences of 200 ps on the hardware delays of the separate codes P1 and P2; however, the final impact on the P3 combination is less than 10 ps.
Bioterrorism and the Role of the Clinical Microbiology Laboratory
2015-01-01
SUMMARY Regular review of the management of bioterrorism is essential for maintaining readiness for these sporadically occurring events. This review provides an overview of the history of biological disasters and bioterrorism. I also discuss the recent recategorization of tier 1 agents by the U.S. Department of Health and Human Services, the Laboratory Response Network (LRN), and specific training and readiness processes and programs, such as the College of American Pathologists (CAP) Laboratory Preparedness Exercise (LPX). LPX examined the management of cultivable bacterial vaccine and attenuated strains of tier 1 agents or close mimics. In the LPX program, participating laboratories showed improvement in the level of diagnosis required and referral of isolates to an appropriate reference laboratory. Agents which proved difficult to manage in sentinel laboratories included the more fastidious Gram-negative organisms, especially Francisella tularensis and Burkholderia spp. The recent Ebola hemorrhagic fever epidemic provided a check on LRN safety processes. Specific guidelines and recommendations for laboratory safety and risk assessment in the clinical microbiology are explored so that sentinel laboratories can better prepare for the next biological disaster. PMID:26656673
International global network of fiducial stations: Scientific and implementation issues
NASA Astrophysics Data System (ADS)
1991-11-01
In this report, an ad hoc panel of the National Research Council's Committee on Geodesy, Board of Earth Sciences and Resources (1) evaluates the scientific importance of a global network of fiducial sites, monitored very precisely, using a combination of surface- and space-geodetic techniques; (2) examines strategies for implementing and operating such a network; and (3) assesses whether such a network would provide a suitable global infrastructure for geodetic and other geophysical systems of the next century. The panel concludes that a global network of fiducial sites would be a valuable tool for addressing global change issues and play a critical role in providing a reference frame for scientific Earth missions. The panel suggests that existing global networks be integrated and anticipates that such a network would grow from about 30 to the ultimate size of about 200 fiducial sites. It is noted that such a global network will provide a long-term infrastructure for geodetic and geophysical studies. The panel expects that these fiducial sites would evolve into terrestrial observatories or laboratories that would permit more comprehensive studies of the Earth than those now possible.
International global network of fiducial stations: Scientific and implementation issues
NASA Technical Reports Server (NTRS)
1991-01-01
In this report, an ad hoc panel of the National Research Council's Committee on Geodesy, Board of Earth Sciences and Resources (1) evaluates the scientific importance of a global network of fiducial sites, monitored very precisely, using a combination of surface- and space-geodetic techniques; (2) examines strategies for implementing and operating such a network; and (3) assesses whether such a network would provide a suitable global infrastructure for geodetic and other geophysical systems of the next century. The panel concludes that a global network of fiducial sites would be a valuable tool for addressing global change issues and play a critical role in providing a reference frame for scientific Earth missions. The panel suggests that existing global networks be integrated and anticipates that such a network would grow from about 30 to the ultimate size of about 200 fiducial sites. It is noted that such a global network will provide a long-term infrastructure for geodetic and geophysical studies. The panel expects that these fiducial sites would evolve into terrestrial observatories or laboratories that would permit more comprehensive studies of the Earth than those now possible.
Alexander, R.B.; Ludtke, A.S.; Fitzgerald, K.K.; Schertz, T.L.
1996-01-01
Data from two U.S. Geological Survey (USGS) national stream water-quality monitoring networks, the National Stream Quality Accounting Network (NASQAN) and the Hydrologic Benchmark Network (HBN), are now available in a two CD-ROM set. These data on CD-ROM are collectively referred to as WQN, water-quality networks. Data from these networks have been used at the national, regional, and local levels to estimate the rates of chemical flux from watersheds, quantify changes in stream water quality for periods during the past 30 years, and investigate relations between water quality and streamflow as well as the relations of water quality to pollution sources and various physical characteristics of watersheds. The networks include 679 monitoring stations in watersheds that represent diverse climatic, physiographic, and cultural characteristics. The HBN includes 63 stations in relatively small, minimally disturbed basins ranging in size from 2 to 2,000 square miles with a median drainage basin size of 57 square miles. NASQAN includes 618 stations in larger, more culturally-influenced drainage basins ranging in size from one square mile to 1.2 million square miles with a median drainage basin size of about 4,000 square miles. The CD-ROMs contain data for 63 physical, chemical, and biological properties of water (122 total constituents including analyses of dissolved and water suspended-sediment samples) collected during more than 60,000 site visits. These data approximately span the periods 1962-95 for HBN and 1973-95 for NASQAN. The data reflect sampling over a wide range of streamflow conditions and the use of relatively consistent sampling and analytical methods. The CD-ROMs provide ancillary information and data-retrieval tools to allow the national network data to be properly and efficiently used. Ancillary information includes the following: descriptions of the network objectives and history, characteristics of the network stations and water-quality data, historical records of important changes in network sample collection and laboratory analytical methods, water reference sample data for estimating laboratory measurement bias and variability for 34 dissolved constituents for the period 1985-95, discussions of statistical methods for using water reference sample data to evaluate the accuracy of network stream water-quality data, and a bibliography of scientific investigations using national network data and other publications relevant to the networks. The data structure of the CD-ROMs is designed to allow users to efficiently enter the water-quality data to user-supplied software packages including statistical analysis, modeling, or geographic information systems. On one disc, all data are stored in ASCII form accessible from any computer system with a CD-ROM driver. The data also can be accessed using DOS-based retrieval software supplied on a second disc. This software supports logical queries of the water-quality data based on constituent concentrations, sample- collection date, river name, station name, county, state, hydrologic unit number, and 1990 population and 1987 land-cover characteristics for station watersheds. User-selected data may be output in a variety of formats including dBASE, flat ASCII, delimited ASCII, or fixed-field for subsequent use in other software packages.
Trends in the Epidemiology of Campylobacteriosis in Israel (1999-2012).
Bassal, Ravit; Lerner, Larisa; Valinsky, Lea; Agmon, Vered; Peled, Nehama; Block, Colin; Keller, Nati; Keness, Yoram; Taran, Diana; Shainberg, Bracha; Ken-Dror, Shifra; Treygerman, Orit; Rouach, Tsvi; Lowenthal, Shulamit; Shohat, Tamar; Cohen, Daniel
2016-08-01
The objective of this study was to examine the recent trends in the epidemiology of campylobacteriosis in Israel. A Sentinel Laboratory-Based Surveillance Network for Bacterial Enteric Diseases was established in Israel by the Israel Center for Disease Control (ICDC). This network generated data on subjects from whom Campylobacter spp. was isolated in community and hospital laboratories. Further characterization of the isolates was done at the Campylobacter National Reference Laboratory. Data from these two sources were integrated and analyzed at the ICDC. Between 1999 and 2012, 40,978 Campylobacter stool isolates were reported to the ICDC by the sentinel laboratories. The incidence rate of campylobacteriosis increased from 65.7 per 100,000 in 1999 to 101.7 per 100,000 in 2012. This increase resulted from a significant rise in the incidence of campylobacteriosis in the Jewish population which, since 2009, surpassed the consistent higher incidence of the disease in Israeli Arabs. The peak morbidity in Israel consistently occurred in late spring, with a risk excess in males compared with females, in younger age groups and earlier in the life span among Arabs than among Jews and others. These results suggest that further analytical studies should be carried out to identify risk factors responsible for the increased incidence of campylobacteriosis and better direct prevention and control of the disease in Israel.
[Tasks and duties of veterinary reference laboratories for food borne zoonoses].
Ellerbroek, Lüppo; Alter, T; Johne, R; Nöckler, K; Beutin, L; Helmuth, R
2009-02-01
Reference laboratories are of central importance for consumer protection. Field expertise and high scientific competence are basic requirements for the nomination of a national reference laboratory. To ensure a common approach in the analysis of zoonotic hazards, standards have been developed by the reference laboratories together with national official laboratories on the basis of Art. 33 of Directive (EG) No. 882/2004. Reference laboratories function as arbitrative boards in the case of ambivalent or debatable results. New methods for detection of zoonotic agents are developed and validated to provide tools for analysis, e. g., in legal cases, if results from different parties are disputed. Besides these tasks, national reference laboratories offer capacity building and advanced training courses and control the performance of ring trials to ensure consistency in the quality of analyses in official laboratories. All reference laboratories work according to the ISO standard 17025 which defines the grounds for strict laboratory quality rules and in cooperation with the respective Community Reference Laboratories (CRL). From the group of veterinary reference laboratories for food-borne zoonoses, the national reference laboratories are responsible for Listeria monocytogenes, for Campylobacter, for the surveillance and control of viral and bacterial contamination of bivalve molluscs, for E. coli, for the performance of analysis and tests on zoonoses (Salmonella), and from the group of parasitological zoonotic agents, the national reference laboratory for Trichinella.
Foo, Yong-Lin; Chow, Julie Chi; Lai, Ming-Chi; Tsai, Wen-Hui; Tung, Li-Chen; Kuo, Mei-Chin; Lin, Shio-Jean
2015-08-01
This review article aims to introduce the screening and referral network of genetic evaluation for children with developmental delay in Taiwan. For these children, integrated systems provide services from the medical, educational, and social welfare sectors. All cities and counties in Taiwan have established a network for screening, detection, referral, evaluation, and intervention services. Increased awareness improves early detection and intervention. There remains a gap between supply and demand, especially with regard to financial resources and professional manpower. Genetic etiology has a major role in prenatal causes of developmental delay. A summary of reports on some related genetic disorders in the Taiwanese population is included in this review. Genetic diagnosis allows counseling with regard to recurrence risk and prevention. Networking with neonatal screening, laboratory diagnosis, genetic counseling, and orphan drugs logistics systems can provide effective treatment for patients. In Taiwan, several laboratories provide genetic tests for clinical diagnosis. Accessibility to advanced expensive tests such as gene chips or whole exome sequencing is limited because of funding problems; however, the service system in Taiwan can still operate in a relatively cost-effective manner. This experience in Taiwan may serve as a reference for other countries. Copyright © 2014. Published by Elsevier B.V.
Adeli, Khosrow; Higgins, Victoria; Seccombe, David; Collier, Christine P; Balion, Cynthia M; Cembrowski, George; Venner, Allison A; Shaw, Julie
2017-11-01
Reference intervals are widely used decision-making tools in laboratory medicine, serving as health-associated standards to interpret laboratory test results. Numerous studies have shown wide variation in reference intervals, even between laboratories using assays from the same manufacturer. Lack of consistency in either sample measurement or reference intervals across laboratories challenges the expectation of standardized patient care regardless of testing location. Here, we present data from a national survey conducted by the Canadian Society of Clinical Chemists (CSCC) Reference Interval Harmonization (hRI) Working Group that examines variation in laboratory reference sample measurements, as well as pediatric and adult reference intervals currently used in clinical practice across Canada. Data on reference intervals currently used by 37 laboratories were collected through a national survey to examine the variation in reference intervals for seven common laboratory tests. Additionally, 40 clinical laboratories participated in a baseline assessment by measuring six analytes in a reference sample. Of the seven analytes examined, alanine aminotransferase (ALT), alkaline phosphatase (ALP), and creatinine reference intervals were most variable. As expected, reference interval variation was more substantial in the pediatric population and varied between laboratories using the same instrumentation. Reference sample results differed between laboratories, particularly for ALT and free thyroxine (FT4). Reference interval variation was greater than test result variation for the majority of analytes. It is evident that there is a critical lack of harmonization in laboratory reference intervals, particularly for the pediatric population. Furthermore, the observed variation in reference intervals across instruments cannot be explained by the bias between the results obtained on instruments by different manufacturers. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Kratz, Alexander
2016-09-01
Results from reference laboratories are often not easily available in electronic health records. This article describes a multi-pronged, long-term approach that includes bringing send-out tests in-house, upgrading the laboratory information system, interfacing more send-out tests and more reference laboratories, utilizing the "miscellaneous assay" option offered by some reference laboratories, and scanning all remaining paper reports from reference laboratories for display in the electronic health record. This allowed all laboratory results obtained in association with a patient visit, whether performed in-house or at a reference laboratory, to be available in the integrated electronic health record. This was achieved without manual data entry of reference laboratory results, thereby avoiding the risk of transcription errors. A fully integrated electronic health record that contains all laboratory results can be achieved by maximizing the number of interfaced reference laboratory assays and making all non-interfaced results available as scanned documents. © The Author(s) 2015.
Ensuring the reliability of stable isotope ratio data--beyond the principle of identical treatment.
Carter, J F; Fry, B
2013-03-01
The need for inter-laboratory comparability is crucial to facilitate the globalisation of scientific networks and the development of international databases to support scientific and criminal investigations. This article considers what lessons can be learned from a series of inter-laboratory comparison exercises organised by the Forensic Isotope Ratio Mass Spectrometry (FIRMS) network in terms of reference materials (RMs), the management of data quality, and technical limitations. The results showed that within-laboratory precision (repeatability) was generally good but between-laboratory accuracy (reproducibility) called for improvements. This review considers how stable isotope laboratories can establish a system of quality control (QC) and quality assurance (QA), emphasising issues of repeatability and reproducibility. For results to be comparable between laboratories, measurements must be traceable to the international δ-scales and, because isotope ratio measurements are reported relative to standards, a key aspect is the correct selection, calibration, and use of international and in-house RMs. The authors identify four principles which promote good laboratory practice. The principle of identical treatment by which samples and RMs are processed in an identical manner and which incorporates three further principles; the principle of identical correction (by which necessary corrections are identified and evenly applied), the principle of identical scaling (by which data are shifted and stretched to the international δ-scales), and the principle of error detection by which QC and QA results are monitored and acted upon. To achieve both good repeatability and good reproducibility it is essential to obtain RMs with internationally agreed δ-values. These RMs will act as the basis for QC and can be used to calibrate further in-house QC RMs tailored to the activities of specific laboratories. In-house QA standards must also be developed to ensure that QC-based calibrations and corrections lead to accurate results for samples. The δ-values assigned to RMs must be recorded and reported with all data. Reference materials must be used to determine what corrections are necessary for measured data. Each analytical sequence of samples must include both QC and QA materials which are subject to identical treatment during measurement and data processing. Results for these materials must be plotted, monitored, and acted upon. Periodically international RMs should be analysed as an in-house proficiency test to demonstrate results are accurate.
NASA Technical Reports Server (NTRS)
Clements, P. A.; Borutzki, S. E.; Kirk, A.
1984-01-01
The Deep Space Network (DSN), managed by the Jet Propulsion Laboratory for NASA, must maintain time and frequency within specified limits in order to accurately track the spacecraft engaged in deep space exploration. Various methods are used to coordinate the clocks among the three tracking complexes. These methods include Loran-C, TV Line 10, Very Long Baseline Interferometry (VLBI), and the Global Positioning System (GPS). Calculations are made to obtain frequency offsets and Allan variances. These data are analyzed and used to monitor the performance of the hydrogen masers that provide the reference frequencies for the DSN Frequency and Timing System (DFT). Areas of discussion are: (1) a brief history of the GPS timing receivers in the DSN, (2) a description of the data and information flow, (3) data on the performance of the DSN master clocks and GPS measurement system, and (4) a description of hydrogen maser frequency steering using these data.
Mulders, Mick N; Serhan, Fatima; Goodson, James L; Icenogle, Joseph; Johnson, Barbara W; Rota, Paul A
2017-07-01
Laboratory networks were established to provide accurate and timely laboratory confirmation of infections, an essential component of disease surveillance systems. The World Health Organization (WHO) coordinates global laboratory surveillance of vaccine-preventable diseases (VPDs), including polio, measles and rubella, yellow fever, Japanese encephalitis, rotavirus, and invasive bacterial diseases. In addition to providing high-quality laboratory surveillance data to help guide disease control, elimination, and eradication programs, these global networks provide capacity-building and an infrastructure for public health laboratories. There are major challenges with sustaining and expanding the global laboratory surveillance capacity: limited resources and the need for expansion to meet programmatic goals. Here, we describe the WHO-coordinated laboratory networks supporting VPD surveillance and present a plan for the further development of these networks. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America.
Characterization of NIES CRM No. 23 Tea Leaves II for the determination of multielements.
Mori, Ikuko; Ukachi, Miyuki; Nagano, Kimiyo; Ito, Hiroyasu; Yoshinaga, Jun; Nishikawa, Masataka
2010-05-01
A candidate environmental certified reference material (CRM) for the determination of multielements in tea leaves and materials of similar matrix, NIES CRM No. 23 Tea Leaves II, has been developed and characterized by the National Institute for Environmental Studies (NIES), Japan. The origin of the material was tea leaves, which were ground, sieved through a 106-microm mesh, homogenized, and then subdivided into amber glass bottles. The results of homogeneity and stability tests indicated that the material was sufficiently homogeneous and stable for use as a reference material. The property values of the material were statistically determined based on chemical analyses by a network of laboratories using a wide range of methods. Sixteen laboratories participated in the characterization, and nine certified values and five reference values were obtained. These property values of the candidate CRM, which are expressed as mass fractions, were close to the median and/or mean values of the mass fractions of elements in various tea products. The candidate CRM is appropriate for use in analytical quality control and in the evaluation of methods used in the analysis of tea and materials of similar matrix.
Namatovu, Alice; Wekesa, Sabenzia Nabalayo; Tjørnehøj, Kirsten; Dhikusooka, Moses Tefula; Muwanika, Vincent B; Siegsmund, Hans Redlef; Ayebazibwe, Chrisostom
2013-01-24
Accurate diagnosis is pertinent to any disease control programme. If Eastern Africa is to work towards control of foot-and-mouth disease (FMD) using the Progressive Control Pathway for FMD (PCP-FMD) as a tool, then the capacity of national reference laboratories (NRLs) mandated to diagnose FMD should match this task. This study assessed the laboratory capacity of 14 NRLs of the Eastern Africa Region Laboratory Network member countries using a semi-structured questionnaire and retrospective data from the World Reference Laboratory for FMD annual reports and Genbank® through National Centre for Biotechnology Information for the period 2006-2010. The questionnaire response rate was 13/14 (93%). Twelve out of the 13 countries/regions had experienced at least one outbreak in the relevant five year period. Only two countries (Ethiopia and Kenya) had laboratories at biosecurity level 3 and only three (Ethiopia, Kenya and Sudan) had identified FMD virus serotypes for all reported outbreaks. Based on their own country/region assessment, 12/13 of these countries /regions were below stage 3 of the PCP-FMD. Quarantine (77%) and vaccination (54%) were the major FMD control strategies employed. The majority (12/13) of the NRLs used serological techniques to diagnose FMD, seven used antigen ELISA and three of these (25%) also used molecular techniques which were the tests most frequently requested from collaborating laboratories by the majority (69%) of the NRLs. Only 4/13 (31%) participated in proficiency testing for FMD. Four (31%) laboratories had no quality management systems (QMS) in place and where QMS existed it was still deficient, thus, none of the laboratories had achieved accreditation for FMD diagnosis. This study indicates that FMD diagnostic capacity in Eastern Africa is still inadequate and largely depends on antigen and antibody ELISAs techniques undertaken by the NRLs. Hence, for the region to progress on the PCP-FMD, there is need to: implement regional control measures, improve the serological diagnostic test performance and laboratory capacity of the NRLs (including training of personnel as well as upgrading of equipment and methods, especially strengthening the molecular diagnostic capacity), and to establish a regional reference laboratory to enforce QMS and characterization of FMD virus containing samples.
2013-01-01
Background Accurate diagnosis is pertinent to any disease control programme. If Eastern Africa is to work towards control of foot-and-mouth disease (FMD) using the Progressive Control Pathway for FMD (PCP-FMD) as a tool, then the capacity of national reference laboratories (NRLs) mandated to diagnose FMD should match this task. This study assessed the laboratory capacity of 14 NRLs of the Eastern Africa Region Laboratory Network member countries using a semi-structured questionnaire and retrospective data from the World Reference Laboratory for FMD annual reports and Genbank® through National Centre for Biotechnology Information for the period 2006–2010. Results The questionnaire response rate was 13/14 (93%). Twelve out of the 13 countries/regions had experienced at least one outbreak in the relevant five year period. Only two countries (Ethiopia and Kenya) had laboratories at biosecurity level 3 and only three (Ethiopia, Kenya and Sudan) had identified FMD virus serotypes for all reported outbreaks. Based on their own country/region assessment, 12/13 of these countries /regions were below stage 3 of the PCP-FMD. Quarantine (77%) and vaccination (54%) were the major FMD control strategies employed. The majority (12/13) of the NRLs used serological techniques to diagnose FMD, seven used antigen ELISA and three of these (25%) also used molecular techniques which were the tests most frequently requested from collaborating laboratories by the majority (69%) of the NRLs. Only 4/13 (31%) participated in proficiency testing for FMD. Four (31%) laboratories had no quality management systems (QMS) in place and where QMS existed it was still deficient, thus, none of the laboratories had achieved accreditation for FMD diagnosis. Conclusions This study indicates that FMD diagnostic capacity in Eastern Africa is still inadequate and largely depends on antigen and antibody ELISAs techniques undertaken by the NRLs. Hence, for the region to progress on the PCP-FMD, there is need to: implement regional control measures, improve the serological diagnostic test performance and laboratory capacity of the NRLs (including training of personnel as well as upgrading of equipment and methods, especially strengthening the molecular diagnostic capacity), and to establish a regional reference laboratory to enforce QMS and characterization of FMD virus containing samples. PMID:23347795
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-24
...] Notice of Availability of a National Animal Health Laboratory Network Reorganization Concept Paper AGENCY... Network (NAHLN) for public review and comment. The NAHLN is a nationally coordinated network and... Coordinator, National Animal Health Laboratory Network, Veterinary Services, APHIS, 2140 Centre Avenue...
65 Years of influenza surveillance by a WHO-coordinated global network.
Ziegler, Thedi; Mamahit, Awandha; Cox, Nancy J
2018-05-04
The 1918 devastating influenza pandemic left a lasting impact on influenza experts and the public, and the importance of global influenza surveillance was soon recognized. The WHO Global Influenza Surveillance Network (GISN) was founded in 1952 and renamed to Global Influenza Surveillance and Response System in 2011 upon the adoption by the World Health Assembly, of the Pandemic Influenza Preparedness Framework for the Sharing of Influenza Viruses and Access to Vaccines and Other Benefits ("PIP Framework"). The importance of influenza surveillance had been recognized and promoted by experts prior to the years leading up to the establishment of WHO. In the 65 years of its existence, the Network has grown to comprise 143 National Influenza Centers recognized by WHO, 6 WHO Collaborating Centers, 4 Essential Regulatory Laboratories, and 13 H5 Reference Laboratories. The Network has proven its excellence throughout these 65 years, providing detailed information on circulating seasonal influenza viruses, as well as immediate response to the influenza pandemics in 1957, 1968, and 2009, and to threats caused by animal influenza viruses and by zoonotic transmission of coronaviruses. For its central role in global public health, the Network has been highly recognized by its many partners and by international bodies. Several generations of world renown influenza scientists have brought the Network to where it is now and they will take it forward to the future, as influenza will remain a pre-eminent threat to humans and to animals. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Global and national laboratory networks support high quality surveillance for measles and rubella.
Xu, Wenbo; Zhang, Yan; Wang, Huiling; Zhu, Zhen; Mao, Naiying; Mulders, Mick N; Rota, Paul A
2017-05-01
Laboratory networks are an essential component of disease surveillance systems because they provide accurate and timely confirmation of infection. WHO coordinates global laboratory surveillance of vaccine preventable diseases, including measles and rubella. The more than 700 laboratories within the WHO Global Measles and Rubella Laboratory Network (GMRLN) supports surveillance for measles, rubella and congenial rubella syndrome in 191 counties. This paper describes the overall structure and function of the GMRLN and highlights the largest of the national laboratory networks, the China Measles and Rubella Laboratory Network. Published by Oxford University Press on behalf of Royal Society of Tropical Medicine and Hygiene 2017. This work is written by (a) US Government employee(s) and is in the public domain in the US.
National and international veterinary reference laboratories for infectious diseases.
Edwards, S; Alexander, D
1998-08-01
Reference laboratories play an increasingly important role in the harmonisation of laboratory diagnostic tests and the standardisation of veterinary vaccines. This is particularly important in building confidence between international trading partners. The authors review aspects of the organisation, designation and support of reference laboratories for infectious diseases of animals and discuss the principal activities which such laboratories would normally perform. These activities include advice and consultancy, publications and communication, training, research, disease surveillance, maintenance of culture collections, evaluation of reference methods, preparation of reference materials and organisation of inter-laboratory comparisons.
Datema, Tjeerd; Keita-Sow, Mah-Sere; Ndihokubwayo, Jean-Bosco; Isadore, Jocelyn; Oskam, Linda; Nkengasong, John; Lewis, Kim
2016-01-01
Background Functional national laboratory networks and systems are indispensable to the achievement of global health security targets according to the International Health Regulations. The lack of indicators to measure the functionality of national laboratory network has limited the efficiency of past and current interventions to enhance laboratory capacity in resource-limited-settings. Scorecard for laboratory networks We have developed a matrix for the assessment of national laboratory network functionality and progress thereof, with support from the African Society of Laboratory Medicine and the Association of Public Health Laboratories. The laboratory network (LABNET) scorecard was designed to: (1) Measure the status of nine overarching core capabilities of laboratory network required to achieve global health security targets, as recommended by the main normative standards; (2) Complement the World Health Organization joint external evaluation tool for the assessment of health system preparedness to International Health Regulations (2005) by providing detailed information on laboratory systems; and (3) Serve as a clear roadmap to guide the stepwise implementation of laboratory capability to prevent, detect and act upon infectious threats. Conclusions The application of the LABNET scorecard under the coordination of the African Society of Laboratory Medicine and the Association of Public Health Laboratories could contribute to the design, monitoring and evaluation of upcoming Global Health Security Agenda-supported laboratory capacity building programmes in sub Saharan-Africa and other resource-limited settings, and inform the development of national laboratory policies and strategic plans. Endorsement by the World Health Organization Regional Office for Africa is foreseen. PMID:28879141
MacMillan, Donna; Lewandrowski, Elizabeth; Lewandrowski, Kent
2004-01-01
Utilization of outside reference laboratories for selected laboratory testing is common in the United States. However, relatively little data exist in the literature describing the scope and impact of these services. In this study, we reviewed use of reference laboratory testing at the Massachusetts General Hospital, a large urban academic medical center in Boston, Massachusetts. A retrospective review of hospital and laboratory administrative records over an 8-year period from fiscal years (FY) 1995-2002. Over the 8 years studied, reference laboratory expenses increased 4.2-fold and totaled 12.4% of the total laboratory budget in FY 2002. Total reference laboratory test volume increased 4-fold to 68,328 tests in FY 2002 but represented only 1.06% of the total test volume in the hospital. The menu of reference laboratory tests comprised 946 tests (65.7% of the hospital test menu) compared to 494 (34.3%) of tests performed in house. The average unit cost of reference laboratory tests was essentially unchanged but was approximately 13 times greater than the average unit cost in the hospital laboratory. Much of the growth in reference laboratory cost can be attributed to the addition of new molecular, genetic, and microbiological assays. Four of the top 10 tests with the highest total cost in 2002 were molecular diagnostic tests that were recently added to the test menu. Reference laboratory testing comprises a major component of hospital clinical laboratory services. Although send out tests represent a small percentage of the total test volume, these services account for the majority of the hospital laboratory test menu and a disproportionate percentage of laboratory costs.
Le, Margaret; Flores, David; May, Danica; Gourley, Eric; Nangia, Ajay K
2016-05-01
The evaluation and management of male hypogonadism should be based on symptoms and on serum testosterone levels. Diagnostically this relies on accurate testing and reference values. Our objective was to define the distribution of reference values and assays for free and total testosterone by clinical laboratories in the United States. Upper and lower reference values, assay methodology and source of published reference ranges were obtained from laboratories across the country. A standardized survey was reviewed with laboratory staff via telephone. Descriptive statistics were used to tabulate results. We surveyed a total of 120 laboratories in 47 states. Total testosterone was measured in house at 73% of laboratories. At the remaining laboratories studies were sent to larger centralized reference facilities. The mean ± SD lower reference value of total testosterone was 231 ± 46 ng/dl (range 160 to 300) and the mean upper limit was 850 ± 141 ng/dl (range 726 to 1,130). Only 9% of laboratories where in-house total testosterone testing was performed created a reference range unique to their region. Others validated the instrument recommended reference values in a small number of internal test samples. For free testosterone 82% of laboratories sent testing to larger centralized reference laboratories where equilibrium dialysis and/or liquid chromatography with mass spectrometry was done. The remaining laboratories used published algorithms to calculate serum free testosterone. Reference ranges for testosterone assays vary significantly among laboratories. The ranges are predominantly defined by limited population studies of men with unknown medical and reproductive histories. These poorly defined and variable reference values, especially the lower limit, affect how clinicians determine treatment. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Relative accuracy of the BD Logic and FreeStyle blood glucose meters.
2007-04-01
The BD Logic((R)) (Becton, Dickinson and Co., Franklin Lakes, NJ) and FreeStyle((R)) (Abbott Diabetes Care, Alameda, CA) meters are used to transmit data directly to insulin pumps for calculation of insulin doses and to calibrate continuous glucose sensors as well as to monitor blood glucose levels. The accuracy of the two meters was evaluated in two inpatient studies conducted by the Diabetes Research in Children Network (DirecNet). In both studies, meter glucose measurements made with either venous or capillary blood were compared with reference glucose measurements made by the DirecNet Central Laboratory at the University of Minnesota using a hexokinase enzymatic method. The BD Logic tended to read lower than the laboratory reference regardless of whether venous (median difference = -9 mg/dL) or capillary blood (median difference = -7 mg/dL) was used. This resulted in lower accuracy of the BD Logic compared with the FreeStyle meter based on the median relative absolute difference (RAD) for both venous blood (median RAD, 9% vs. 5%, P < 0.001) and capillary blood (median RAD, 11% vs. 6%, P = 0.008). The greatest discrepancy in the performance of the two meters was at higher reference glucose values. Accuracy was not significantly different when the reference was < or = 70 mg/dL. The BD Logic meter is less accurate than the FreeStyle meter.
Wireless sensor node for surface seawater density measurements.
Baronti, Federico; Fantechi, Gabriele; Roncella, Roberto; Saletti, Roberto
2012-01-01
An electronic meter to measure surface seawater density is presented. It is based on the measurement of the difference in displacements of a surface level probe and a weighted float, which according to Archimedes' law depends on the density of the water. The displacements are simultaneously measured using a high-accuracy magnetostrictive sensor, to which a custom electronic board provides a wireless connection and power supply so that it can become part of a wireless sensor network. The electronics are designed so that different kinds of wireless networks can be used, by simply changing the wireless module and the relevant firmware of the microcontroller. Lastly, laboratory and at-sea tests are presented and discussed in order to highlight the functionality and the performance of a prototype of the wireless density meter node in a Bluetooth radio network. The experimental results show a good agreement of the values of the calculated density compared to reference hydrometer readings.
Wireless Sensor Node for Surface Seawater Density Measurements
Baronti, Federico; Fantechi, Gabriele; Roncella, Roberto; Saletti, Roberto
2012-01-01
An electronic meter to measure surface seawater density is presented. It is based on the measurement of the difference in displacements of a surface level probe and a weighted float, which according to Archimedes’ law depends on the density of the water. The displacements are simultaneously measured using a high-accuracy magnetostrictive sensor, to which a custom electronic board provides a wireless connection and power supply so that it can become part of a wireless sensor network. The electronics are designed so that different kinds of wireless networks can be used, by simply changing the wireless module and the relevant firmware of the microcontroller. Lastly, laboratory and at-sea tests are presented and discussed in order to highlight the functionality and the performance of a prototype of the wireless density meter node in a Bluetooth radio network. The experimental results show a good agreement of the values of the calculated density compared to reference hydrometer readings. PMID:22736986
NASA Astrophysics Data System (ADS)
Birmili, W.; Weinhold, K.; Merkel, M.; Rasch, F.; Sonntag, A.; Wiedensohler, A.; Bastian, S.; Schladitz, A.; Löschau, G.; Cyrys, J.; Pitz, M.; Gu, J.; Kusch, T.; Flentje, H.; Quass, U.; Kaminski, H.; Kuhlbusch, T. A. J.; Meinhardt, F.; Schwerin, A.; Bath, O.; Ries, L.; Wirtz, K.; Fiebig, M.
2015-11-01
The German Ultrafine Aerosol Network (GUAN) is a cooperative atmospheric observation network, which aims at improving the scientific understanding of aerosol-related effects in the troposphere. The network addresses research questions dedicated to both, climate and health related effects. GUAN's core activity has been the continuous collection of tropospheric particle number size distributions and black carbon mass concentrations at seventeen observation sites in Germany. These sites cover various environmental settings including urban traffic, urban background, rural background, and Alpine mountains. In association with partner projects, GUAN has implemented a high degree of harmonisation of instrumentation, operating procedures, and data evaluation procedures. The quality of the measurement data is assured by laboratory intercomparisons as well as on-site comparisons with reference instruments. This paper describes the measurement sites, instrumentation, quality assurance and data evaluation procedures in the network as well as the EBAS repository, where the data sets can be obtained (doi:10.5072/guan).
NASA Astrophysics Data System (ADS)
Birmili, Wolfram; Weinhold, Kay; Rasch, Fabian; Sonntag, André; Sun, Jia; Merkel, Maik; Wiedensohler, Alfred; Bastian, Susanne; Schladitz, Alexander; Löschau, Gunter; Cyrys, Josef; Pitz, Mike; Gu, Jianwei; Kusch, Thomas; Flentje, Harald; Quass, Ulrich; Kaminski, Heinz; Kuhlbusch, Thomas A. J.; Meinhardt, Frank; Schwerin, Andreas; Bath, Olaf; Ries, Ludwig; Gerwig, Holger; Wirtz, Klaus; Fiebig, Markus
2016-08-01
The German Ultrafine Aerosol Network (GUAN) is a cooperative atmospheric observation network, which aims at improving the scientific understanding of aerosol-related effects in the troposphere. The network addresses research questions dedicated to both climate- and health-related effects. GUAN's core activity has been the continuous collection of tropospheric particle number size distributions and black carbon mass concentrations at 17 observation sites in Germany. These sites cover various environmental settings including urban traffic, urban background, rural background, and Alpine mountains. In association with partner projects, GUAN has implemented a high degree of harmonisation of instrumentation, operating procedures, and data evaluation procedures. The quality of the measurement data is assured by laboratory intercomparisons as well as on-site comparisons with reference instruments. This paper describes the measurement sites, instrumentation, quality assurance, and data evaluation procedures in the network as well as the EBAS repository, where the data sets can be obtained (doi:10.5072/guan).
Ondoa, Pascale; Datema, Tjeerd; Keita-Sow, Mah-Sere; Ndihokubwayo, Jean-Bosco; Isadore, Jocelyn; Oskam, Linda; Nkengasong, John; Lewis, Kim
2016-01-01
Functional national laboratory networks and systems are indispensable to the achievement of global health security targets according to the International Health Regulations. The lack of indicators to measure the functionality of national laboratory network has limited the efficiency of past and current interventions to enhance laboratory capacity in resource-limited-settings. We have developed a matrix for the assessment of national laboratory network functionality and progress thereof, with support from the African Society of Laboratory Medicine and the Association of Public Health Laboratories. The laboratory network (LABNET) scorecard was designed to: (1) Measure the status of nine overarching core capabilities of laboratory network required to achieve global health security targets, as recommended by the main normative standards; (2) Complement the World Health Organization joint external evaluation tool for the assessment of health system preparedness to International Health Regulations (2005) by providing detailed information on laboratory systems; and (3) Serve as a clear roadmap to guide the stepwise implementation of laboratory capability to prevent, detect and act upon infectious threats. The application of the LABNET scorecard under the coordination of the African Society of Laboratory Medicine and the Association of Public Health Laboratories could contribute to the design, monitoring and evaluation of upcoming Global Health Security Agenda-supported laboratory capacity building programmes in sub Saharan-Africa and other resource-limited settings, and inform the development of national laboratory policies and strategic plans. Endorsement by the World Health Organization Regional Office for Africa is foreseen.
Meini, Genny; Dello Russo, Cinzia; Allice, Tiziano; Barresi, Renata; D'Arrigo, Roberta; Falasca, Francesca; Lipsi, Maria Rosaria; Paolucci, Stefania; Zanussi, Stefania; Antonetti, Raffaele; Baldanti, Fausto; Basaglia, Giancarlo; Bruzzone, Bianca; Polilli, Ennio; Ghisetti, Valeria; Pucillo, Leopoldo Paolo; Turriziani, Ombretta; Pirazzoli, Antonella; Navarra, Pierluigi; Zazzi, Maurizio
2016-05-01
Since the HLA-B*57:01 allele is strongly associated with abacavir hypersensitivity reaction, testing for the presence of HLA-B*57:01 is mandatory before administration of abacavir. While HLA-B*57:01 testing is usually provided by pharmacogenetics, genetics or blood transfusion services, clinical virology laboratories can be an optimal opportunity for HLA-B*57:01 testing since they receive blood samples for routine HIV monitoring and have the expertise for convenient and less expensive PCR-based point mutation assays. The Italian HLA-B*57:01 Network gathers accredited clinical virology laboratories offering HLA-B*57:01 testing in Italy with the aim to share protocols, test new methods, develop and maintain external quality assurance (EQA) programs. A panel of 9HLA-B*57:01-positive and 16HLA-B*57:01-negative frozen blood samples were blindly distributed to 10 units including 9 clinical virology laboratories and one reference pharmacology laboratory. Each laboratory was free to use its own routine method for DNA extraction and HLA-B*57:01 testing. DNA was extracted by automated workstations in 6 units and by manual spin columns in 4. Eight units used the Duplicα Real Time HLA-B*57:01 kit by Euroclone and two units used two different PCR homemade protocols. All the 10 units correctly identified all the 25 samples. The first HLA-B*57:01 EQA program run in Italy showed that clinical virology units are equipped and proficient for providing HLA-B*57:01 testing by inexpensive assays easy to integrate into their routine. Copyright © 2016 Elsevier B.V. All rights reserved.
ERIC Educational Resources Information Center
Hwang, Wu-Yuin; Kongcharoen, Chaknarin; Ghinea, Gheorghita
2014-01-01
Recently, various computer networking courses have included additional laboratory classes in order to enhance students' learning achievement. However, these classes need to establish a suitable laboratory where each student can connect network devices to configure and test functions within different network topologies. In this case, the Linux…
Precise Clock Solutions Using Carrier Phase from GPS Receivers in the International GPS Service
NASA Technical Reports Server (NTRS)
Zumberge, J. F.; Jefferson, D. C.; Stowers, D. A.; Tjoelker, R. L.; Young, L. E.
1999-01-01
As one of its activities as an Analysis Center in the International GPS Service (IGS), the Jet Propulsion Laboratory (JPL) uses data from a globally distributed network of geodetic-quality GPS receivers to estimate precise clock solutions, relative to a chosen reference, for both the GPS satellites and GPS receiver internal clocks, every day. The GPS constellation and ground network provide geometrical strength resulting in formal errors of about 100 p sec for these estimates. Some of the receivers in the global IGS network contain high quality frequency references, such as hydrogen masers. The clock solutions for such receivers are smooth at the 20-p sec level on time scales of a few minutes. There are occasional (daily to weekly) shifts at the microsec level, symptomatic of receiver resets, and 200-p sec-level discontinuities at midnight due to 1-day processing boundaries. Relative clock solutions among 22 IGS sites proposed as "fiducial" in the IGS/BIPM pilot project have been examined over a recent 4-week period. This allows a quantitative measure of receiver reset frequency as a function of site. For days and-sites without resets, the Allan deviation of the relative clock solutions is also computed for subdaily values of tau..
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arp, J.A.; Bower, J.C.; Burnett, R.A.
The Federal Emergency Management Information System (FEMIS) is an emergency management planning and response tool that was developed by the Pacific Northwest National Laboratory (PNNL) under the direction of the U.S. Army Chemical Biological Defense Command. The FEMIS System Administration Guide provides information necessary for the system administrator to maintain the FEMIS system. The FEMIS system is designed for a single Chemical Stockpile Emergency Preparedness Program (CSEPP) site that has multiple Emergency Operations Centers (EOCs). Each EOC has personal computers (PCs) that emergency planners and operations personnel use to do their jobs. These PCs are corrected via a local areamore » network (LAN) to servers that provide EOC-wide services. Each EOC is interconnected to other EOCs via a Wide Area Network (WAN). Thus, FEMIS is an integrated software product that resides on client/server computer architecture. The main body of FEMIS software, referred to as the FEMIS Application Software, resides on the PC client(s) and is directly accessible to emergency management personnel. The remainder of the FEMIS software, referred to as the FEMIS Support Software, resides on the UNIX server. The Support Software provides the communication data distribution and notification functionality necessary to operate FEMIS in a networked, client/server environment.« less
Federal Emergency Management Information System (FEMIS), Installation Guide for FEMIS 1.4.6
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arp, J.A.; Burnett, R.A.; Carter, R.J.
The Federal Emergency Management Information System (FEMIS) is an emergency management planning and response tool that was developed by the Pacific Northwest National Laboratory (PNNL) under the direction of the U.S. Army Chemical Biological Defense Command. The FEMIS System Administration Guide provides information necessary for the system administrator to maintain the FEMIS system. The FEMIS system is designed for a single Chemical Stockpile Emergency Preparedness Program (CSEPP) site that has multiple Emergency Operations Centers (EOCs). Each EOC has personal computers (PCs) that emergency planners and operations personnel use to do their jobs. These PCs are corrected via a local areamore » network (LAN) to servers that provide EOC-wide services. Each EOC is interconnected to other EOCs via a Wide Area Network (WAN). Thus, FEMIS is an integrated software product that resides on client/server computer architecture. The main body of FEMIS software, referred to as the FEMIS Application Software, resides on the PC client(s) and is directly accessible to emergency management personnel. The remainder of the FEMIS software, referred to as the FEMIS Support Software, resides on the UNIX server. The Support Software provides the communication data distribution and notification functionality necessary to operate FEMIS in a networked, client/server environment.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Angel, L.K.; Bower, J.C.; Burnett, R.A.
1999-06-29
The Federal Emergency Management Information System (FEMIS) is an emergency management planning and response tool that was developed by the Pacific Northwest National Laboratory (PNNL) under the direction of the U.S. Army Chemical Biological Defense Command. The FEMIS System Administration Guide provides information necessary for the system administrator to maintain the FEMIS system. The FEMIS system is designed for a single Chemical Stockpile Emergency Preparedness Program (CSEPP) site that has multiple Emergency Operations Centers (EOCs). Each EOC has personal computers (PCs) that emergency planners and operations personnel use to do their jobs. These PCs are corrected via a local areamore » network (LAN) to servers that provide EOC-wide services. Each EOC is interconnected to other EOCs via a Wide Area Network (WAN). Thus, FEMIS is an integrated software product that resides on client/server computer architecture. The main body of FEMIS software, referred to as the FEMIS Application Software, resides on the PC client(s) and is directly accessible to emergency management personnel. The remainder of the FEMIS software, referred to as the FEMIS Support Software, resides on the UNIX server. The Support Software provides the communication data distribution and notification functionality necessary to operate FEMIS in a networked, client/server environment.« less
Discrepancies in reporting the CAG repeat lengths for Huntington's disease
Quarrell, Oliver W; Handley, Olivia; O'Donovan, Kirsty; Dumoulin, Christine; Ramos-Arroyo, Maria; Biunno, Ida; Bauer, Peter; Kline, Margaret; Landwehrmeyer, G Bernhard
2012-01-01
Huntington's disease results from a CAG repeat expansion within the Huntingtin gene; this is measured routinely in diagnostic laboratories. The European Huntington's Disease Network REGISTRY project centrally measures CAG repeat lengths on fresh samples; these were compared with the original results from 121 laboratories across 15 countries. We report on 1326 duplicate results; a discrepancy in reporting the upper allele occurred in 51% of cases, this reduced to 13.3% and 9.7% when we applied acceptable measurement errors proposed by the American College of Medical Genetics and the Draft European Best Practice Guidelines, respectively. Duplicate results were available for 1250 lower alleles; discrepancies occurred in 40% of cases. Clinically significant discrepancies occurred in 4.0% of cases with a potential unexplained misdiagnosis rate of 0.3%. There was considerable variation in the discrepancy rate among 10 of the countries participating in this study. Out of 1326 samples, 348 were re-analysed by an accredited diagnostic laboratory, based in Germany, with concordance rates of 93% and 94% for the upper and lower alleles, respectively. This became 100% if the acceptable measurement errors were applied. The central laboratory correctly reported allele sizes for six standard reference samples, blind to the known result. Our study differs from external quality assessment (EQA) schemes in that these are duplicate results obtained from a large sample of patients across the whole diagnostic range. We strongly recommend that laboratories state an error rate for their measurement on the report, participate in EQA schemes and use reference materials regularly to adjust their own internal standards. PMID:21811303
Regional Educational Laboratory Electronic Network Phase 2 System
NASA Technical Reports Server (NTRS)
Cradler, John
1995-01-01
The Far West Laboratory in collaboration with the other regional educational laboratories is establishing a regionally coordinated telecommunication network to electronically interconnect each of the ten regional laboratories with educators and education stakeholders from the school to the state level. For the national distributed information database, each lab is working with mid-level networks to establish a common interface for networking throughout the country and include topics of importance to education reform as assessment and technology planning.
Dimech, Wayne; Lim, Megan S C; Van Gemert, Caroline; Guy, Rebecca; Boyle, Douglas; Donovan, Basil; Hellard, Margaret
2014-06-12
Chlamydial infection is the most common notifiable disease in Australia, Europe and the US. Australian notifications of chlamydia rose four-fold from 20,274 cases in 2002 to 80,846 cases in 2011; the majority of cases were among young people aged less than 29 years. Along with test positivity rates, an understanding of the number of tests performed and the demographics of individuals being tested are key epidemiological indicators. The ACCESS Laboratory Network was established in 2008 to address this issue. The ACCESS Laboratory Network collected chlamydia testing data from 15 laboratories around Australia over a three-year period using data extraction software. All chlamydia testing data from participating laboratories were extracted from the laboratory information system; patient identifiers converted to a unique, non-reversible code and de-identified data sent to a single database. Analysis of data by anatomical site included all specimens, but in age and sex specific analysis, only one testing episode was counted. From 2008 to 2010 a total of 628,295 chlamydia tests were referred to the 15 laboratories. Of the 592,626 individual episodes presenting for testing, 70% were from female and 30% from male patients. In female patients, chlamydia positivity rate was 6.4% overall; the highest rate in 14 year olds (14.3%). In male patients, the chlamydia positivity rate was 9.4% overall; the highest in 19 year olds (16.5%). The most common sample type was urine (57%). In 3.2% of testing episodes, multiple anatomical sites were sampled. Urethral swabs gave the highest positivity rate for all anatomical sites in both female (7.7%) and male patients (14%), followed by urine (7.6% and 9.4%, respectively) and eye (6.3% and 7.9%, respectively). The ACCESS Laboratory Network data are unique in both number and scope and are representative of chlamydia testing in both general practice and high-risk clinics. The findings from these data highlight much lower levels of testing in young people aged 20 years or less; in particular female patients aged less than 16 years, despite being the group with the highest positivity rate. Strategies are needed to increase the uptake of testing in this high-risk group.
2014-01-01
Background Chlamydial infection is the most common notifiable disease in Australia, Europe and the US. Australian notifications of chlamydia rose four-fold from 20,274 cases in 2002 to 80,846 cases in 2011; the majority of cases were among young people aged less than 29 years. Along with test positivity rates, an understanding of the number of tests performed and the demographics of individuals being tested are key epidemiological indicators. The ACCESS Laboratory Network was established in 2008 to address this issue. Methods The ACCESS Laboratory Network collected chlamydia testing data from 15 laboratories around Australia over a three-year period using data extraction software. All chlamydia testing data from participating laboratories were extracted from the laboratory information system; patient identifiers converted to a unique, non-reversible code and de-identified data sent to a single database. Analysis of data by anatomical site included all specimens, but in age and sex specific analysis, only one testing episode was counted. Results From 2008 to 2010 a total of 628,295 chlamydia tests were referred to the 15 laboratories. Of the 592,626 individual episodes presenting for testing, 70% were from female and 30% from male patients. In female patients, chlamydia positivity rate was 6.4% overall; the highest rate in 14 year olds (14.3%). In male patients, the chlamydia positivity rate was 9.4% overall; the highest in 19 year olds (16.5%). The most common sample type was urine (57%). In 3.2% of testing episodes, multiple anatomical sites were sampled. Urethral swabs gave the highest positivity rate for all anatomical sites in both female (7.7%) and male patients (14%), followed by urine (7.6% and 9.4%, respectively) and eye (6.3% and 7.9%, respectively). Conclusions The ACCESS Laboratory Network data are unique in both number and scope and are representative of chlamydia testing in both general practice and high-risk clinics. The findings from these data highlight much lower levels of testing in young people aged 20 years or less; in particular female patients aged less than 16 years, despite being the group with the highest positivity rate. Strategies are needed to increase the uptake of testing in this high-risk group. PMID:24920016
National Biocontainment Training Center
2015-08-01
this year, including representatives from within the NBL -RBL Network, UTMB students, and representatives from other biocontainment laboratories and...following the annual NBL /RBL Network meeting in Galveston, the Biosafety Officer from the Regional Biocontainment Laboratory at Colorado State...Biocontainment Laboratory Network Meeting - Miguel Grimaldo participated in the steering committee and planning efforts for the two-day NBL /RBL Network Meeting
Integrated Approach to Reconstruction of Microbial Regulatory Networks
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rodionov, Dmitry A; Novichkov, Pavel S
2013-11-04
This project had the goal(s) of development of integrated bioinformatics platform for genome-scale inference and visualization of transcriptional regulatory networks (TRNs) in bacterial genomes. The work was done in Sanford-Burnham Medical Research Institute (SBMRI, P.I. D.A. Rodionov) and Lawrence Berkeley National Laboratory (LBNL, co-P.I. P.S. Novichkov). The developed computational resources include: (1) RegPredict web-platform for TRN inference and regulon reconstruction in microbial genomes, and (2) RegPrecise database for collection, visualization and comparative analysis of transcriptional regulons reconstructed by comparative genomics. These analytical resources were selected as key components in the DOE Systems Biology KnowledgeBase (SBKB). The high-quality data accumulated inmore » RegPrecise will provide essential datasets of reference regulons in diverse microbes to enable automatic reconstruction of draft TRNs in newly sequenced genomes. We outline our progress toward the three aims of this grant proposal, which were: Develop integrated platform for genome-scale regulon reconstruction; Infer regulatory annotations in several groups of bacteria and building of reference collections of microbial regulons; and Develop KnowledgeBase on microbial transcriptional regulation.« less
NASA Astrophysics Data System (ADS)
Wymore, Adam S.; Potter, Jody; Rodríguez-Cardona, Bianca; McDowell, William H.
2018-04-01
The advent of high-frequency in situ optical sensors provides new opportunities to study the biogeochemistry of dissolved organic matter (DOM) in aquatic ecosystems. We used fDOM (fluorescent dissolved organic matter) to examine the spatial and temporal variability in dissolved organic carbon (DOC) and dissolved organic nitrogen (DON) across a heterogeneous stream network that varies in NO3- concentration. Across the ten study streams fDOM explained twice the variability in the concentration of DOC (r2 = 0.82) compared to DON (r2 = 0.39), which suggests that the N-rich fraction of DOM is either more variable in its sources or more bioreactive than the more stable C-rich fraction. Among sites, DON molar fluorescence was approximately 3x more variable than DOC molar fluorescence and was correlated with changes in inorganic N, indicating that DON is both more variable in composition as well as highly responsive to changes in inorganic N. Laboratory results also indicate that the fDOM sensors we used perform as well as the excitation-emission wavelength pair generally referred to as the "tryptophan-like" peak when measured under laboratory conditions. However, since neither the field sensor not the laboratory measurements explained a large percentage of variation in DON concentrations, challenges still remain for monitoring the ambient pool of dissolved organic nitrogen. Sensor networks provide new insights into the potential reactivity of DOM and the variability in DOC and DON biogeochemistry across sites. These insights are needed to build spatially explicit models describing organic matter dynamics and water quality.
Lyme borreliosis: an update for Canadian dermatologists.
Potok, Olivia V; Brassard, Alain
2013-01-01
Lyme borreliosis is a multisystemic tick-borne spirochetosis, which may result in dermatologic, musculoskeletal, cardiovascular, and neurologic manifestations. Patients with suspected acute Lyme borreliosis infection may be referred for urgent dermatologic review. Canadian dermatologists should be aware of the latest information regarding the diagnosis and management of Lyme borreliosis. This review is based on a PubMed database search combining the word "Lyme" with variations of the word "Canada." Data sources included articles from the fields of ecology, epidemiology, laboratory diagnostics, and clinical management. In this review, the ecological basis of spirochete transmission by tick vectors is described. The latest available Canadian epidemiologic data are summarized. North American clinical manifestations of Lyme borreliosis are contrasted with European presentations. The Canadian Public Health Laboratory Network's diagnostic guidelines are summarized. Finally, treatment recommendations are outlined.
Bankson, Daniel D; Heim, Joseph A
2014-01-01
To optimize transportation processes, we present herein a contingency plan that coordinates interim measures used to ensure continued and timely services when climate based events might cause an interruption of the usual specimen transportation processes. As an example, we outline the implementation and effectiveness of a contingency plan for network laboratory courier automobile transportation during times of mountain pass highway closure. Data available from an approximately 3-year period from October 10, 2010 through August 29, 2013 revealed a total of 690 complete closures in the eastbound or westbound lanes of the Interstate-90 highway in the Snoqualmie Pass area in the state of Washington. Despite the frequency of closures, the Washington State Department of Transportation was effective in limiting the duration of closures. Road closures of less than 1 hour accounted for 58.7% of the total closures. No recorded closures prevented dispatched couriers from completing a prescheduled Snoqualmie Pass route. We identified no delays as being clinically significant, despite that there were 5 instances of delays greater than 4 hours. We implemented a contingency plan of aiding courier logistics during all times of pass closure. The plan includes an easy to interpret Condition Dashboard as a status indicator and a Decision Tree that references and summarizes information. Overall, the contingency plan allows for an objective, robust, proactive decision support system that has enabled operational flexibility and has contributed to continued safe, on-time specimen transportation; clients and courier and reference laboratory staff have appreciated these features and associated outcomes. Copyright© by the American Society for Clinical Pathology (ASCP).
Web-Based Virtual Laboratory for Food Analysis Course
NASA Astrophysics Data System (ADS)
Handayani, M. N.; Khoerunnisa, I.; Sugiarti, Y.
2018-02-01
Implementation of learning on food analysis course in Program Study of Agro-industrial Technology Education faced problems. These problems include the availability of space and tools in the laboratory that is not comparable with the number of students also lack of interactive learning tools. On the other hand, the information technology literacy of students is quite high as well the internet network is quite easily accessible on campus. This is a challenge as well as opportunities in the development of learning media that can help optimize learning in the laboratory. This study aims to develop web-based virtual laboratory as one of the alternative learning media in food analysis course. This research is R & D (research and development) which refers to Borg & Gall model. The results showed that assessment’s expert of web-based virtual labs developed, in terms of software engineering aspects; visual communication; material relevance; usefulness and language used, is feasible as learning media. The results of the scaled test and wide-scale test show that students strongly agree with the development of web based virtual laboratory. The response of student to this virtual laboratory was positive. Suggestions from students provided further opportunities for improvement web based virtual laboratory and should be considered for further research.
NASA Astrophysics Data System (ADS)
Mielke-Maday, I.
2015-12-01
The National Oceanic and Atmospheric Administration (NOAA) Global Monitoring Division (GMD) maintains a global reference network for over 50 trace gas species and analyzes discrete air samples collected by this network throughout the world at the Earth System Research Laboratory in Boulder, Colorado. In particular, flask samples are analyzed for a number of hydrocarbons with policy and health relevance such as ozone precursors, greenhouse gases, and hazardous air pollutants. Because this global network's sites are remote and therefore minimally influenced by local anthropogenic emissions, these data yield information about background ambient mole fractions and can provide a context for observations collected in intensive field campaigns, such as the Front Range Air Pollution and Photochemistry Experiment (FRAPPE), the Southeast Nexus (SENEX) study, and the DISCOVER-AQ deployments. Information about background mole fractions during field campaigns is critical for calculating hydrocarbon enhancements in the region of study and for assessing the extent to which a particular region's local emissions sources contribute to these enhancements. Understanding the geographic variability of the background and its contribution to regional ambient mole fractions is also crucial for the development of realistic regulations. We present background hydrocarbon mole fractions and their ratios in North America using data from air samples collected in the planetary boundary layer at tall towers and aboard aircraft from 2008 to 2014. We discuss the spatial and seasonal variability in these data. We present trends over the time period of measurements and propose possible explanations for these trends.
[The running status of Chinese Measles Laboratory Network in 2008].
Zhang, Yan; Xu, Song-Tao; Jiang, Xiao-Hong
2009-04-01
To evaluate the running status of Measles laboratory network of China (Hong Kong, Macao and Taiwan were excluded) in 2008. To analyze the database of Measles laboratory network surveillance of the year 2008, and the database of serologic and virologic surveillance of National laboratory for Measles in Chinese Centers for Disease Control and Prevention(CCDC), then the indicators of the running of Measles laboratory network of China were analyzed. 1, serologic surveillance: 107,160 Measles sera samples were collected between Feburary and September of 2008, and the collection rate was 77.93%; 53 778 samples were qualified and positive for IgM, the positive percentage was 50.2%. 2, Virologic surveillance: 287 Measles viral isolates were isolated by 18 provincial Measles laboratories in 2008, all were certified as H1a genotype, H1a genotype was still the predominant genotype circulating in China; 29 Rubella viral isolates were isolated by 4 provincial Measles laboratories in 2008, all belonged to 1E genotype. 3, Laboratory quality control: National laboratory for Measles passed the proficiency test and on-site review in 2008; all provincial Measles laboratories passed the sera samples recheck and proficiency test hold by National laboratory for Measles in 2008; Tianjin, Shanxi, Shandong, Zhejiang, Jilin, Hubei, provincial Measles laboratory passed the on-site review by WHO. The running status of Chinese Measles laboratory network was good in 2008, and good laboratory quality control system was also set up, methods such as specimens collection, serologic detection, cell culture and viral isolation, etc, were standardized, and applied to Chinese Measles laboratory network, and it provided important scientific basis for eradication Measles in the year of 2012.
Daniels, Peter; Poermadjaja, Bagoes; Morrissy, Chris; Ngo, Thanh Long; Selleck, Paul; Kalpravidh, Wantanee; Weaver, John; Wong, Frank; Torchetti, Mia Kim; Allen, John; Padungtod, Parwin; Davis, Andrew; Suradhat, Sanipa; Morzaria, Subhash
2014-01-01
The outbreak of highly pathogenic H5N1 avian influenza, with its international spread, confirmed that emerging infectious disease control must be underpinned by effective laboratory services. Laboratory results are the essential data underpinning effective surveillance, case diagnosis, or monitoring of responses. Importantly, laboratories are best managed within national and international networks of technological support rather than in isolation. A well planned laboratory network can deliver both a geographical spread of testing capacity and also a cost effective hierarchy of capability. Hence in the international context regional networks can be particularly effective. Laboratories are an integral part of a country's veterinary services and their role and function should be clearly defined in the national animal health strategy and supporting government policies. Not every laboratory should be expected to deliver every possible service, and integration into regional and broader international networks should be a part of the overall strategy. The outputs required of each laboratory should be defined and then ensured through accredited quality assurance. The political and scientific environment in which laboratories operate changes continuously, not only through evolving national and regional animal health priorities but also through new test technologies and enhancements to existing technologies. Active networks help individual laboratories to monitor, evaluate, and respond to such challenges and opportunities. The end result is enhanced emerging infectious disease preparedness across the region.
Building Cross-Country Networks for Laboratory Capacity and Improvement.
Schneidman, Miriam; Matu, Martin; Nkengasong, John; Githui, Willie; Kalyesubula-Kibuuka, Simeon; Silva, Kelly Araujo
2018-03-01
Laboratory networks are vital to well-functioning public health systems and disease control efforts. Cross-country laboratory networks play a critical role in supporting epidemiologic surveillance, accelerating disease outbreak response, and tracking drug resistance. The East Africa Public Health Laboratory Network was established to bolster diagnostic and disease surveillance capacity. The network supports the introduction of regional quality standards; facilitates the rollout and evaluation of new diagnostic tools; and serves as a platform for training, research, and knowledge sharing. Participating facilities benefitted from state-of-the art investments, capacity building, and mentorship; conducted multicountry research studies; and contributed to disease outbreak response. Copyright © 2017 Elsevier Inc. All rights reserved.
Asynchronous reference frame agreement in a quantum network
NASA Astrophysics Data System (ADS)
Islam, Tanvirul; Wehner, Stephanie
2016-03-01
An efficient implementation of many multiparty protocols for quantum networks requires that all the nodes in the network share a common reference frame. Establishing such a reference frame from scratch is especially challenging in an asynchronous network where network links might have arbitrary delays and the nodes do not share synchronised clocks. In this work, we study the problem of establishing a common reference frame in an asynchronous network of n nodes of which at most t are affected by arbitrary unknown error, and the identities of the faulty nodes are not known. We present a protocol that allows all the correctly functioning nodes to agree on a common reference frame as long as the network graph is complete and not more than t\\lt n/4 nodes are faulty. As the protocol is asynchronous, it can be used with some assumptions to synchronise clocks over a network. Also, the protocol has the appealing property that it allows any existing two-node asynchronous protocol for reference frame agreement to be lifted to a robust protocol for an asynchronous quantum network.
[Evaluation on running status of Chinese Polio Laboratories Network in 2008].
Zhu, Shuang-li; Yan, Dong-mei; Zhu, Hui
2010-04-01
In order to evaluate the running status and provide the laboratory data for maintaining polio-free status in China, the virology surveillance database of Chinese Polio Laboratories Network (not include Hong Kong, Macao, and Taiwan)in 2008 were analyzed. The case investigation data of Acute Flaccid Paralysis(AFP)cases reported by 31 provinces (municipal, autonomous regions) through EPI surveillance information management system and the database of National Polio Laboratory (NPL) were analyzed, and the indicators of running status of Chinese Polio Laboratories Network were evaluated. 10,116 stool samples were collected from 5116 AFP cases by Chinese Polio Laboratories Network in 2008, and viral isolation and identification of all stool samples were done according to 4th World Health Organization (WHO) Polio Laboratory Manual. The rate of viral isolation and identification performed within 28d was 94.9%. 189 polioviruses (PV) and 597 of non-polio enteroviruses (NPEV) were isolated from AFP cases, the isolatien rates were 3.72% and 11.74% respectively. 251 polio positive isolates were sent to NPL from 31 provincial polio laboratories. There were 318 single serotype PVs were performed VPI sequencing. And no wild polioviruses and Vaccine-derived Polioviruses (VDPVs) were found in 2008. NPL passed the proficiency test and got full accreditation for on-site review by WHO experts in 2008. All 31 provincial Polio laboratories passed the proficiency test with the same panel as NPL, and 13 provincial Polio laboratories joined and passed the on-site review by WHO experts. The running status of Chinese Polio Laboratories Network was good, polio-free status was maintained in China in 2008. The Chinese polio laboratories network running is normaly, the laboratory surveillance system was sensitive and laboratory data were provided for maintaining the polio-free status in China.
Requirements for data integration platforms in biomedical research networks: a reference model.
Ganzinger, Matthias; Knaup, Petra
2015-01-01
Biomedical research networks need to integrate research data among their members and with external partners. To support such data sharing activities, an adequate information technology infrastructure is necessary. To facilitate the establishment of such an infrastructure, we developed a reference model for the requirements. The reference model consists of five reference goals and 15 reference requirements. Using the Unified Modeling Language, the goals and requirements are set into relation to each other. In addition, all goals and requirements are described textually in tables. This reference model can be used by research networks as a basis for a resource efficient acquisition of their project specific requirements. Furthermore, a concrete instance of the reference model is described for a research network on liver cancer. The reference model is transferred into a requirements model of the specific network. Based on this concrete requirements model, a service-oriented information technology architecture is derived and also described in this paper.
The quality of veterinary in-clinic and reference laboratory biochemical testing.
Rishniw, Mark; Pion, Paul D; Maher, Tammy
2012-03-01
Although evaluation of biochemical analytes in blood is common in veterinary practice, studies assessing the global quality of veterinary in-clinic and reference laboratory testing have not been reported. The aim of this study was to assess the quality of biochemical testing in veterinary laboratories using results obtained from analyses of 3 levels of assayed quality control materials over 5 days. Quality was assessed by comparison of calculated total error with quality requirements, determination of sigma metrics, use of a quality goal index to determine factors contributing to poor performance, and agreement between in-clinic and reference laboratory mean results. The suitability of in-clinic and reference laboratory instruments for statistical quality control was determined using adaptations from the computerized program, EZRules3. Reference laboratories were able to achieve desirable quality requirements more frequently than in-clinic laboratories. Across all 3 materials, > 50% of in-clinic analyzers achieved a sigma metric ≥ 6.0 for measurement of 2 analytes, whereas > 50% of reference laboratory analyzers achieved a sigma metric ≥ 6.0 for measurement of 6 analytes. Expanded uncertainty of measurement and ± total allowable error resulted in the highest mean percentages of analytes demonstrating agreement between in-clinic and reference laboratories. Owing to marked variation in bias and coefficient of variation between analyzers of the same and different types, the percentages of analytes suitable for statistical quality control varied widely. These findings reflect the current state-of-the-art with regard to in-clinic and reference laboratory analyzer performance and provide a baseline for future evaluations of the quality of veterinary laboratory testing. © 2012 American Society for Veterinary Clinical Pathology.
Identifying gene networks underlying the neurobiology of ethanol and alcoholism.
Wolen, Aaron R; Miles, Michael F
2012-01-01
For complex disorders such as alcoholism, identifying the genes linked to these diseases and their specific roles is difficult. Traditional genetic approaches, such as genetic association studies (including genome-wide association studies) and analyses of quantitative trait loci (QTLs) in both humans and laboratory animals already have helped identify some candidate genes. However, because of technical obstacles, such as the small impact of any individual gene, these approaches only have limited effectiveness in identifying specific genes that contribute to complex diseases. The emerging field of systems biology, which allows for analyses of entire gene networks, may help researchers better elucidate the genetic basis of alcoholism, both in humans and in animal models. Such networks can be identified using approaches such as high-throughput molecular profiling (e.g., through microarray-based gene expression analyses) or strategies referred to as genetical genomics, such as the mapping of expression QTLs (eQTLs). Characterization of gene networks can shed light on the biological pathways underlying complex traits and provide the functional context for identifying those genes that contribute to disease development.
Stambos, Vicki; Leydon, Jennie; Riddell, Michaela; Clothier, Hazel; Catton, Mike; Featherstone, David; Kelly, Heath
2011-07-01
During 2001-2008, the Victorian Infectious Diseases Reference Laboratory (VIDRL) prepared and provided a measles and rubella proficiency test panel for distribution to the World Health Organization (WHO) measles and rubella network laboratories as part of their annual laboratory accreditation assessment. Panel test results were forwarded to VIDRL, and results from 8 consecutive years were analyzed. We assessed the type of assays used and results achieved on the basis of the positive and negative interpretation of submitted results, by year and WHO region, for measles and rubella. Over time, there has been a noticeable increase in laboratory and WHO regional participation. For all panels, the proportion of laboratories in all WHO regions using the WHO-validated Dade Behring assay for measles and rubella-specific IgM antibodies ranged from 35% to 100% and 59% to 100%, respectively. For all regions and years, the proportion of laboratories obtaining a pass score ranged from 87% to 100% for measles and 93% to 100% for rubella. During 2001-2008, a large proportion of laboratories worldwide achieved and maintained a pass score for both measles and rubella. Measles and rubella proficiency testing is regarded as a major achievement for the WHO measles and rubella laboratory program. © The Author 2011. Published by Oxford University Press on behalf of the Infectious Diseases Society of America. All rights reserved.
Joloba, Moses; Mwangi, Christina; Alexander, Heather; Nadunga, Diana; Bwanga, Freddie; Modi, Nelson; Downing, Robert; Nabasirye, Agnes; Adatu, Francis E; Shrivastava, Ritu; Gadde, Renuka; Nkengasong, John N
2016-04-15
Diagnosis of multidrug-resistant tuberculosis and prompt initiation of effective treatment rely on access to rapid and reliable drug-susceptibility testing. Efficient specimen transport systems and appropriate training on specimen referral contribute to optimal and timely access to tuberculosis diagnostic services. With support and technical assistance from a public-private partnership (PPP) between Becton Dickinson and the US President's Emergency Plan for AIDS Relief, the Uganda National TB Reference Laboratory (NTRL) and National TB and Leprosy Program redesigned the tuberculosis specimen transport network and trained healthcare workers with the goal of improving multidrug-resistant tuberculosis detection. Between 2008 and 2011, the PPP mapped 93% of health facilities and trained 724 healthcare and postal staff members covering 72% of districts. Strengthening the tuberculosis specimen referral system increased referrals from presumptive multidrug-resistant tuberculosis cases by >10-fold, with 94% of specimens reaching the NTRL within the established target transport time. This study demonstrates the potential of PPP collaborations with ministries of health to positively influence patient care by strengthening laboratory systems through increased access to drug-susceptibility testing in Uganda. Ongoing efforts to integrate specimen transport networks will maximize resources and improve patient management. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.
Determination of reference ranges for elements in human scalp hair.
Druyan, M E; Bass, D; Puchyr, R; Urek, K; Quig, D; Harmon, E; Marquardt, W
1998-06-01
Expected values, reference ranges, or reference limits are necessary to enable clinicians to apply analytical chemical data in the delivery of health care. Determination of references ranges is not straightforward in terms of either selecting a reference population or performing statistical analysis. In light of logistical, scientific, and economic obstacles, it is understandable that clinical laboratories often combine approaches in developing health associated reference values. A laboratory may choose to: 1. Validate either reference ranges of other laboratories or published data from clinical research or both, through comparison of patients test data. 2. Base the laboratory's reference values on statistical analysis of results from specimens assayed by the clinical reference laboratory itself. 3. Adopt standards or recommendations of regulatory agencies and governmental bodies. 4. Initiate population studies to validate transferred reference ranges or to determine them anew. Effects of external contamination and anecdotal information from clinicians may be considered. The clinical utility of hair analysis is well accepted for some elements. For others, it remains in the realm of clinical investigation. This article elucidates an approach for establishment of reference ranges for elements in human scalp hair. Observed levels of analytes from hair specimens from both our laboratory's total patient population and from a physician-defined healthy American population have been evaluated. Examination of levels of elements often associated with toxicity serves to exemplify the process of determining reference ranges in hair. In addition the approach serves as a model for setting reference ranges for analytes in a variety of matrices.
Proficiency Tests for Environmental Radioactivity Measurement Organized by an Accredited Laboratory
NASA Astrophysics Data System (ADS)
Aubert, Cédric; Osmond, Mélanie
2008-08-01
For 40 years, STEME (Environmental Sample Processing and Metrology Department) organized international proficiency testing (PT) exercises formerly for WHO (World Health Organization) and EC (European Community) and currently for ASN (French Nuclear Safety Authority). Five PT exercises are organized each year for the measurement of radionuclides (alpha, beta and gamma) in different matrixes (water, soil, biological and air samples) at environmental levels. ASN can deliver a French ministerial agreement to participate on environmental radioactivity measurements French network for laboratories asking it [1]. Since 2006, November, STEME is the first French entity obtaining a COFRAC (French Committee of Accreditation) accreditation as "Interlaboratory Comparisons" for the organization of proficiency tests for environmental radioactivity measurement according to standard International Standard Organization (ISO) 17025 and guide ISO 43-1. STEME has in charge to find, as far as possible, real sample or to create, by radionuclide adding, an adapted sample. STEME realizes the sampling, the samples preparation and the dispatching. STEME is also accredited according to Standard 17025 for radioactivity measurements in environmental samples and determines homogeneity, stability and reference values. After the reception of participating laboratories results, STEME executes statistical treatments in order to verify the normal distribution, to eliminate outliers and to evaluate laboratories performance. Laboratories participate with several objectives, to obtain French agreement, to prove the quality of their analytical performance in regards to standard 17025 or to validate new methods or latest developments. For 2 years, in addition to usual PT exercises, new PT about alpha or beta measurement in air filters, radioactive iodine in carbon cartridges or measurement of environmental dosimeters are organized. These PT exercises help laboratories to improve radioactive measurements and to rectify old mistakes. The PT exercises organized by STEME are becoming essential for French and some European laboratories working in radioactive measurements. The STEME organization, in respect of accreditation references, is presented.
Proficiency Tests for Environmental Radioactivity Measurement Organized by an Accredited Laboratory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aubert, Cedric; Osmond, Melanie
2008-08-14
For 40 years, STEME (Environmental Sample Processing and Metrology Department) organized international proficiency testing (PT) exercises formerly for WHO (World Health Organization) and EC (European Community) and currently for ASN (French Nuclear Safety Authority). Five PT exercises are organized each year for the measurement of radionuclides (alpha, beta and gamma) in different matrixes (water, soil, biological and air samples) at environmental levels. ASN can deliver a French ministerial agreement to participate on environmental radioactivity measurements French network for laboratories asking it. Since 2006, November, STEME is the first French entity obtaining a COFRAC (French Committee of Accreditation) accreditation as 'Interlaboratorymore » Comparisons' for the organization of proficiency tests for environmental radioactivity measurement according to standard International Standard Organization (ISO) 17025 and guide ISO 43-1. STEME has in charge to find, as far as possible, real sample or to create, by radionuclide adding, an adapted sample. STEME realizes the sampling, the samples preparation and the dispatching. STEME is also accredited according to Standard 17025 for radioactivity measurements in environmental samples and determines homogeneity, stability and reference values. After the reception of participating laboratories results, STEME executes statistical treatments in order to verify the normal distribution, to eliminate outliers and to evaluate laboratories performance.Laboratories participate with several objectives, to obtain French agreement, to prove the quality of their analytical performance in regards to standard 17025 or to validate new methods or latest developments. For 2 years, in addition to usual PT exercises, new PT about alpha or beta measurement in air filters, radioactive iodine in carbon cartridges or measurement of environmental dosimeters are organized. These PT exercises help laboratories to improve radioactive measurements and to rectify old mistakes. The PT exercises organized by STEME are becoming essential for French and some European laboratories working in radioactive measurements.The STEME organization, in respect of accreditation references, is presented.« less
Laboratory surveillance for wild and vaccine-derived polioviruses, January 2004-June 2005.
2005-09-30
A global network of 145 virology laboratories has been established by the World Health Organization (WHO) to support surveillance activities of the Polio Eradication Initiative (PEI). The Global Polio Laboratory Network analyzes stool specimens from patients with acute flaccid paralysis (AFP) and environmental samples for the presence of polioviruses. Surveillance systems detect at least one AFP case per 100,000 persons aged <15 years, collect adequate stool samples from patients, and send the samples to network laboratories for analysis. Laboratory data are used to identify locations where wild polioviruses (WPVs) or vaccine-derived polioviruses (VDPVs) are circulating, target supplementary immunization activities (SIAs) to interrupt transmission chains, and investigate genetic relationships among viral isolates. This report updates previous publications and describes the laboratory network's performance during the period January 2004-June 2005.
Flegar-Meštrić, Zlata; Perkov, Sonja; Radeljak, Andrea
2016-03-26
Considering the fact that the results of laboratory tests provide useful information about the state of health of patients, determination of reference value is considered an intrinsic part in the development of laboratory medicine. There are still huge differences in the analytical methods used as well as in the associated reference intervals which could consequently significantly affect the proper assessment of patient health. In a constant effort to increase the quality of patients' care, there are numerous international initiatives for standardization and/or harmonization of laboratory diagnostics in order to achieve maximum comparability of laboratory test results and improve patient safety. Through the standardization and harmonization processes of analytical methods the ability to create unique reference intervals is achieved. Such reference intervals could be applied globally in all laboratories using methods traceable to the same reference measuring system and analysing the biological samples from the populations with similar socio-demographic and ethnic characteristics. In this review we outlined the results of the harmonization processes in Croatia in the field of population based reference intervals for clinically relevant blood and serum constituents which are in accordance with ongoing activity for worldwide standardization and harmonization based on traceability in laboratory medicine.
Flegar-Meštrić, Zlata; Perkov, Sonja; Radeljak, Andrea
2016-01-01
Considering the fact that the results of laboratory tests provide useful information about the state of health of patients, determination of reference value is considered an intrinsic part in the development of laboratory medicine. There are still huge differences in the analytical methods used as well as in the associated reference intervals which could consequently significantly affect the proper assessment of patient health. In a constant effort to increase the quality of patients’ care, there are numerous international initiatives for standardization and/or harmonization of laboratory diagnostics in order to achieve maximum comparability of laboratory test results and improve patient safety. Through the standardization and harmonization processes of analytical methods the ability to create unique reference intervals is achieved. Such reference intervals could be applied globally in all laboratories using methods traceable to the same reference measuring system and analysing the biological samples from the populations with similar socio-demographic and ethnic characteristics. In this review we outlined the results of the harmonization processes in Croatia in the field of population based reference intervals for clinically relevant blood and serum constituents which are in accordance with ongoing activity for worldwide standardization and harmonization based on traceability in laboratory medicine. PMID:27019800
A National Residue Control Plan from the analytical perspective--the Brazilian case.
Mauricio, Angelo de Q; Lins, Erick S; Alvarenga, Marcelo B
2009-04-01
Food safety is a strategic topic entailing not only national public health aspects but also competitiveness in international trade. An important component of any food safety program is the control and monitoring of residues posed by certain substances involved in food production. In turn, a National Residue Control Plan (NRCP) relies on an appropriate laboratory network, not only to generate analytical results, but also more broadly to verify and co-validate the controls built along the food production chain. Therefore laboratories operating under a NRCP should work in close cooperation with inspection bodies, fostering the critical alignment of the whole system with the principles of risk analysis. Beyond producing technically valid results, these laboratories should arguably be able to assist in the prediction and establishment of targets for official control. In pursuit of analytical excellence, the Brazilian government has developed a strategic plan for Official Agricultural Laboratories. Inserted in a national agenda for agricultural risk analysis, the plan has succeeded in raising laboratory budget by approximately 200%, it has started a rigorous program for personnel capacity-building, it has initiated strategic cooperation with international reference centres, and finally, it has completely renewed instrumental resources and rapidly triggered a program aimed at full laboratory compliance with ISO/IEC 17025 requirements.
2011-01-01
Background There is substantial variation in reported reference intervals for canine plasma creatinine among veterinary laboratories, thereby influencing the clinical assessment of analytical results. The aims of the study was to determine the inter- and intra-laboratory variation in plasma creatinine among 10 veterinary laboratories, and to compare results from each laboratory with the upper limit of its reference interval. Methods Samples were collected from 10 healthy dogs, 10 dogs with expected intermediate plasma creatinine concentrations, and 10 dogs with azotemia. Overlap was observed for the first two groups. The 30 samples were divided into 3 batches and shipped in random order by postal delivery for plasma creatinine determination. Statistical testing was performed in accordance with ISO standard methodology. Results Inter- and intra-laboratory variation was clinically acceptable as plasma creatinine values for most samples were usually of the same magnitude. A few extreme outliers caused three laboratories to fail statistical testing for consistency. Laboratory sample means above or below the overall sample mean, did not unequivocally reflect high or low reference intervals in that laboratory. Conclusions In spite of close analytical results, further standardization among laboratories is warranted. The discrepant reference intervals seem to largely reflect different populations used in establishing the reference intervals, rather than analytical variation due to different laboratory methods. PMID:21477356
Environmental Response Laboratory Network (ERLN) Laboratory Requirements
The Environmental Response Laboratory Network requires its member labs follow specified quality systems, sample management, data reporting, and general, in order to ensure consistent analytical data of known and documented quality.
Schellenberg, François; Wielders, Jos; Anton, Raymond; Bianchi, Vincenza; Deenmamode, Jean; Weykamp, Cas; Whitfield, John; Jeppsson, Jan-Olof; Helander, Anders
2017-02-01
Carbohydrate-deficient transferrin (CDT) is used as a biomarker of sustained high alcohol consumption. The currently available measurement procedures for CDT are based on various analytical techniques (HPLC, capillary electrophoresis, nephelometry), some differing in the definition of the analyte and using different reference intervals and cut-off values. The Working Group on Standardization of CDT (WG-CDT), initiated by the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC), has validated an HPLC candidate reference measurement procedure (cRMP) for CDT (% disialotransferrin to total transferrin based on peak areas), demonstrating that it is suitable as a reference measurement procedure (RMP) for CDT. Presented is a detailed description of the cRMP and its calibration. Practical aspects on how to treat genetic variant and so-called di-tri bridge samples are described. Results of method performance characteristics, as demanded by ISO 15189 and ISO 15193, are given, as well as the reference interval and measurement uncertainty and how to deal with that in routine use. The correlation of the cRMP with commercial CDT procedures and the performance of the cRMP in a network of laboratories are also presented. The performance of the CDT cRMP in combination with previously developed commutable calibrators allows for standardization of the currently available commercial measurement procedures for CDT. The cRMP has recently been approved by the IFCC and will be from now on be known as the IFCC-RMP for CDT, while CDT results standardized according to this RMP should be indicated as CDT IFCC . Copyright © 2016 Elsevier B.V. All rights reserved.
Requirements for data integration platforms in biomedical research networks: a reference model
Knaup, Petra
2015-01-01
Biomedical research networks need to integrate research data among their members and with external partners. To support such data sharing activities, an adequate information technology infrastructure is necessary. To facilitate the establishment of such an infrastructure, we developed a reference model for the requirements. The reference model consists of five reference goals and 15 reference requirements. Using the Unified Modeling Language, the goals and requirements are set into relation to each other. In addition, all goals and requirements are described textually in tables. This reference model can be used by research networks as a basis for a resource efficient acquisition of their project specific requirements. Furthermore, a concrete instance of the reference model is described for a research network on liver cancer. The reference model is transferred into a requirements model of the specific network. Based on this concrete requirements model, a service-oriented information technology architecture is derived and also described in this paper. PMID:25699205
Sundqvist, Bo; Bengtsson, Ulrika Allard; Wisselink, Henk J; Peeters, Ben P H; van Rotterdam, Bart; Kampert, Evelien; Bereczky, Sándor; Johan Olsson, N G; Szekely Björndal, Asa; Zini, Sylvie; Allix, Sébastien; Knutsson, Rickard
2013-09-01
Laboratory response networks (LRNs) have been established for security reasons in several countries including the Netherlands, France, and Sweden. LRNs function in these countries as a preparedness measure for a coordinated diagnostic response capability in case of a bioterrorism incident or other biocrimes. Generally, these LRNs are organized on a national level. The EU project AniBioThreat has identified the need for an integrated European LRN to strengthen preparedness against animal bioterrorism. One task of the AniBioThreat project is to suggest a plan to implement laboratory biorisk management CWA 15793:2011 (CWA 15793), a management system built on the principle of continual improvement through the Plan-Do-Check-Act (PDCA) cycle. The implementation of CWA 15793 can facilitate trust and credibility in a future European LRN and is an assurance that the work done at the laboratories is performed in a structured way with continuous improvements. As a first step, a gap analysis was performed to establish the current compliance status of biosafety and laboratory biosecurity management with CWA 15793 in 5 AniBioThreat partner institutes in France (ANSES), the Netherlands (CVI and RIVM), and Sweden (SMI and SVA). All 5 partners are national and/or international laboratory reference institutes in the field of public or animal health and possess high-containment laboratories and animal facilities. The gap analysis showed that the participating institutes already have robust biorisk management programs in place, but several gaps were identified that need to be addressed. Despite differences between the participating institutes in their compliance status, these variations are not significant. Biorisk management exercises also have been identified as a useful tool to control compliance status and thereby implementation of CWA 15793. An exercise concerning an insider threat and loss of a biological agent was performed at SVA in the AniBioThreat project to evaluate implementation of the contingency plans and as an activity in the implementation process of CWA 15793. The outcome of the exercise was perceived as very useful, and improvements to enhance biorisk preparedness were identified. Gap analyses and exercises are important, useful activities to facilitate implementation of CWA 15793. The PDCA cycle will enforce a structured way to work, with continual improvements concerning biorisk management activities. Based on the activities in the AniBioThreat project, the following requirements are suggested to promote implementation: support from the top management of the organizations, knowledge about CWA 15793, a compliance audit checklist and gap analysis, training and exercises, networking in LRNs and other networks, and interinstitutional audits. Implementation of CWA 15793 at each institute would strengthen the European animal bioterrorism response capabilities by establishing a well-prepared LRN.
The Joint Committee for Traceability in Laboratory Medicine (JCTLM) - its history and operation.
Jones, Graham R D; Jackson, Craig
2016-01-30
The Joint Committee for Traceability in Laboratory Medicine (JCTLM) was formed to bring together the sciences of metrology, laboratory medicine and laboratory quality management. The aim of this collaboration is to support worldwide comparability and equivalence of measurement results in clinical laboratories for the purpose of improving healthcare. The JCTLM has its origins in the activities of international metrology treaty organizations, professional societies and federations devoted to improving measurement quality in physical, chemical and medical sciences. The three founding organizations, the International Committee for Weights and Measures (CIPM), the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) and the International Laboratory Accreditation Cooperation (ILAC) are the leaders of this activity. The main service of the JCTLM is a web-based database with a list of reference materials, reference methods and reference measurement services meeting appropriate international standards. This database allows manufacturers to select references for assay traceability and provides support for suppliers of these services. As of mid 2015 the database lists 295 reference materials for 162 analytes, 170 reference measurement procedures for 79 analytes and 130 reference measurement services for 39 analytes. There remains a need for the development and implementation of metrological traceability in many areas of laboratory medicine and the JCTLM will continue to promote these activities into the future. Copyright © 2015 Elsevier B.V. All rights reserved.
Transport equations of electrodiffusion processes in the laboratory reference frame.
Garrido, Javier
2006-02-23
The transport equations of electrodiffusion processes use three reference frames for defining the fluxes: Fick's reference in diffusion, solvent-fixed reference in transference numbers, and laboratory fluxes in electric conductivity. The convenience of using only one reference frame is analyzed here from the point of view of the thermodynamics of irreversible processes. A relation between the fluxes of ions and solvent and the electric current density is deduced first from a mass and volume balance. This is then used to show that (i) the laboratory and Fick's diffusion coefficients are identical and (ii) the transference numbers of both the solvent and the ion in the laboratory reference frame are related. Finally, four experimental methods for the measurement of ion transference numbers are analyzed critically. New expressions for evaluating transference numbers for the moving boundary method and the chronopotentiometry technique are deduced. It is concluded that the ion transport equation in the laboratory reference frame plays a key role in the description of electrodiffusion processes.
Kwong, Jason C; Lane, Courtney R; Romanes, Finn; Gonçalves da Silva, Anders; Easton, Marion; Cronin, Katie; Waters, Mary Jo; Tomita, Takehiro; Stevens, Kerrie; Schultz, Mark B; Baines, Sarah L; Sherry, Norelle L; Carter, Glen P; Mu, Andre; Sait, Michelle; Ballard, Susan A; Seemann, Torsten; Stinear, Timothy P; Howden, Benjamin P
2018-01-01
Until recently, Klebsiella pneumoniae carbapenemase (KPC)-producing Enterobacteriaceae were rarely identified in Australia. Following an increase in the number of incident cases across the state of Victoria, we undertook a real-time combined genomic and epidemiological investigation. The scope of this study included identifying risk factors and routes of transmission, and investigating the utility of genomics to enhance traditional field epidemiology for informing management of established widespread outbreaks. All KPC-producing Enterobacteriaceae isolates referred to the state reference laboratory from 2012 onwards were included. Whole-genome sequencing was performed in parallel with a detailed descriptive epidemiological investigation of each case, using Illumina sequencing on each isolate. This was complemented with PacBio long-read sequencing on selected isolates to establish high-quality reference sequences and interrogate characteristics of KPC-encoding plasmids. Initial investigations indicated that the outbreak was widespread, with 86 KPC-producing Enterobacteriaceae isolates ( K. pneumoniae 92%) identified from 35 different locations across metropolitan and rural Victoria between 2012 and 2015. Initial combined analyses of the epidemiological and genomic data resolved the outbreak into distinct nosocomial transmission networks, and identified healthcare facilities at the epicentre of KPC transmission. New cases were assigned to transmission networks in real-time, allowing focussed infection control efforts. PacBio sequencing confirmed a secondary transmission network arising from inter-species plasmid transmission. Insights from Bayesian transmission inference and analyses of within-host diversity informed the development of state-wide public health and infection control guidelines, including interventions such as an intensive approach to screening contacts following new case detection to minimise unrecognised colonisation. A real-time combined epidemiological and genomic investigation proved critical to identifying and defining multiple transmission networks of KPC Enterobacteriaceae, while data from either investigation alone were inconclusive. The investigation was fundamental to informing infection control measures in real-time and the development of state-wide public health guidelines on carbapenemase-producing Enterobacteriaceae surveillance and management.
Twenty-first-century medical microbiology services in the UK.
Duerden, Brian
2005-12-01
With infection once again a high priority for the UK National Health Service (NHS), the medical microbiology and infection-control services require increased technology resources and more multidisciplinary staff. Clinical care and health protection need a coordinated network of microbiology services working to consistent standards, provided locally by NHS Trusts and supported by the regional expertise and national reference laboratories of the new Health Protection Agency. Here, I outline my thoughts on the need for these new resources and the ways in which clinical microbiology services in the UK can best meet the demands of the twenty-first century.
Network Science Research Laboratory (NSRL) Discrete Event Toolkit
2016-01-01
ARL-TR-7579 ● JAN 2016 US Army Research Laboratory Network Science Research Laboratory (NSRL) Discrete Event Toolkit by...Laboratory (NSRL) Discrete Event Toolkit by Theron Trout and Andrew J Toth Computational and Information Sciences Directorate, ARL...Research Laboratory (NSRL) Discrete Event Toolkit 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Theron Trout
Earth Regimes Network Evolution Study (ERNESt): Introducing the Space Mobile Network
NASA Technical Reports Server (NTRS)
Menrad, Bob
2016-01-01
Speaker and Presenter at the Lincoln Laboratory Communications Workshop on April 5, 2016 at the Massachusetts Institute of Technology Lincoln Laboratory in Lexington, MA. A visual presentation titled Earth Regimes Network Evolution Study (ERNESt).
Bremer, James; Bertagnolio, Silvia
2012-01-01
The World Health Organization (WHO) has developed a global laboratory network to support human immunodeficiency virus drug resistance genotyping for public health surveillance in resource-limited countries. Blinded proficiency panels are an essential part of a genotyping quality-assurance program and are used to monitor the reliability of genotyping data in the WHO laboratory network. Laboratories in Europe, North America, Asia, Africa, and the Caribbean have tested panels annually since 2007; 103 of 131 submissions (79%) had >99% nucleotide sequence identity and resistance mutation concordance, compared with consensus. Most errors were associated with mixtures in the test specimen, leading to subjectivity in base-calling or amplification bias. Overall, genotyping assays used by the WHO laboratory network are reliable. PMID:22544186
Empirical Reference Distributions for Networks of Different Size
Smith, Anna; Calder, Catherine A.; Browning, Christopher R.
2016-01-01
Network analysis has become an increasingly prevalent research tool across a vast range of scientific fields. Here, we focus on the particular issue of comparing network statistics, i.e. graph-level measures of network structural features, across multiple networks that differ in size. Although “normalized” versions of some network statistics exist, we demonstrate via simulation why direct comparison is often inappropriate. We consider normalizing network statistics relative to a simple fully parameterized reference distribution and demonstrate via simulation how this is an improvement over direct comparison, but still sometimes problematic. We propose a new adjustment method based on a reference distribution constructed as a mixture model of random graphs which reflect the dependence structure exhibited in the observed networks. We show that using simple Bernoulli models as mixture components in this reference distribution can provide adjusted network statistics that are relatively comparable across different network sizes but still describe interesting features of networks, and that this can be accomplished at relatively low computational expense. Finally, we apply this methodology to a collection of ecological networks derived from the Los Angeles Family and Neighborhood Survey activity location data. PMID:27721556
The role of total laboratory automation in a consolidated laboratory network.
Seaberg, R S; Stallone, R O; Statland, B E
2000-05-01
In an effort to reduce overall laboratory costs and improve overall laboratory efficiencies at all of its network hospitals, the North Shore-Long Island Health System recently established a Consolidated Laboratory Network with a Core Laboratory at its center. We established and implemented a centralized Core Laboratory designed around the Roche/Hitachi CLAS Total Laboratory Automation system to perform the general and esoteric laboratory testing throughout the system in a timely and cost-effective fashion. All remaining STAT testing will be performed within the Rapid Response Laboratories (RRLs) at each of the system's hospitals. Results for this laboratory consolidation and implementation effort demonstrated a decrease in labor costs and improved turnaround time (TAT) at the core laboratory. Anticipated system savings are approximately $2.7 million. TATs averaged 1.3 h within the Core Laboratory and less than 30 min in the RRLs. When properly implemented, automation systems can reduce overall laboratory expenses, enhance patient services, and address the overall concerns facing the laboratory today: job satisfaction, decreased length of stay, and safety. The financial savings realized are primarily a result of labor reductions.
Parker, Samantha
2014-09-01
This review aims to provide guidance on emerging concepts and policy related to European reference networks (ERNs) for rare diseases (RDs) and the development and management of RD patient registries. A major problem facing many RDs including rare renal disorders is that patients do not have a specialist centre that they can attend where clinicians, working as a multidisciplinary team, are experts in the particular disease. Furthermore, for most RDs, no single centre, and in many cases no single country, has sufficient numbers of patients and resources to fully understand the natural history or to conduct clinical and translational research. Therefore, the pooling of manpower and resources through the establishment of ERN and RD patient registries is a common and necessary area of collaboration. The concept of European networks for RDs dates back to the early 2000s and the Commission launch of a call for European pilot reference networks for RDs. These networks of expert centres have been brought together through the desire for further knowledge and innovation in RD areas. Networks demand a holistic approach and long-term vision with close collaboration between clinicians, diagnostic laboratories, scientists, patients and their families. The development of legal measures for ERNs is in progress at the Commission and these networks will be a shared responsibility of the Commission and member states. In the context of ERNs, an essential activity is the patient registries. Patient registries are organized databases where patient information, including demographic, medical and family history, are collected, stored and available for retrieval via standardized and secure methods. Patient registries are increasingly recognized as crucial tools for RD research for which international collaboration is absolutely essential to understand the pathogenesis of rare genotypes, achieve a unified collection of phenotypic data, foster natural history studies providing the foundation for successful orphan drug development, facilitate studies to identify appropriate clinical endpoints or biomarkers, identify participants for research and clinical trials and support discussions with regulators including the safety and efficacy evaluation of potential therapies. Furthermore, patient registries are often used as part of regulatory decisions and post-marketing surveillance requirements. Data can be entered into a registry by patients, clinicians, researchers or directly imported from patient's health records. The major concern in maintaining the dynamic of these networks and registries is sustainability, as the infrastructures and coordination have a cost. © The Author 2014. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.
Kebede, Yenew; Fonjungo, Peter N.; Tibesso, Gudeta; Shrivastava, Ritu; Nkengasong, John N.; Kenyon, Thomas; Kebede, Amha; Gadde, Renuka; Ayana, Gonfa
2016-01-01
Background. Nonstandardized specimen-transport logistics, lack of laboratory personnel to transport specimens, lack of standard specimen containers, and long turnaround time (TAT) hindered access to quality laboratory services. The objective of the Becton, Dickinson, and Company (BD)–US President's Emergency Plan for AIDS Relief (PEPFAR) Public-Private Partnership (PPP) was to support country-specific programs to develop integrated laboratory systems, services, and quality improvement strategies, with an emphasis on strengthening the specimen-referral system (SRS). Methods. In 2007, through the Centers for Disease Control and Prevention (CDC), the Ethiopian Public Health Institute (EPHI) joined with the BD-PEPFAR PPP to strengthen laboratory systems. A joint planning and assessment committee identified gaps in the SRS for prioritization and intervention and piloted the system in Addis Ababa and Amhara Region. Results. The PPP established standardized, streamlined specimen logistics, using the Ethiopian Postal Service Enterprise to support a laboratory network in which 554 facilities referred specimens to 160 laboratories. The PPP supported procuring 400 standard specimen containers and the training of 586 laboratory personnel and 81 postal workers. The average TAT was reduced from 7 days (range, 2–14 days) to 2 days (range, 1–3 days) in Addis Ababa and from 10 days (range, 6–21 days) to 5 days (range, 2–6 days) in Amhara Region. Conclusions. This study highlights the feasibility and untapped potential of PPPs to strengthen laboratory systems. This planned and structured approach to improving specimen referral enhanced access to quality laboratory services. PMID:27025700
Takemura, Y; Ishibashi, M
2000-02-01
Failure to slow the exponential growth of total health care expenditures in the United States through the government policies resulted in a rapid and progressive penetration of managed care organizations(MCOs) in the early 1990s. Diagnostic testing is viewed as a "commodity" rather than a medical service under the managed care environment. Traditional hospital-based laboratories are placed in a downward spiral with the advent of managed care era. A massive reduction of in-house testing resulted from shorter lengths of patients' hospital stay and a marked decrease in admission under the dominance of managed care urges them to develop strategies for restoring tests deprived by the managed care-associated new businesses: consolidation and networking, participation in the outreach-testing market, and point-of-care/satellite laboratory testing in non-traditional, ambulatory settings are major strategies for survival of hospital laboratories. A number of physicians' office laboratories(POLs) have been closed owing to regulatory restrictions imposed by the Clinical Laboratory Improvement Amendments of 1988(CLIA '88), and to the expanded penetration of MCOs which limit reimbursement to a very few in-house procedures. It seems likely that POLs and hospital laboratories continue to reduce test volumes, while commercial reference laboratories(CRLs) gain more tests through contracting with MCOs. In the current stream of managed care dominance in the United States, clinical laboratories are changing their basic operation focus and mission in response to the aggressively changing landscape. Traditional laboratories which are unwilling to adapt themselves to the new environment will not survive in this country.
Recommendation for the review of biological reference intervals in medical laboratories.
Henny, Joseph; Vassault, Anne; Boursier, Guilaine; Vukasovic, Ines; Mesko Brguljan, Pika; Lohmander, Maria; Ghita, Irina; Andreu, Francisco A Bernabeu; Kroupis, Christos; Sprongl, Ludek; Thelen, Marc H M; Vanstapel, Florent J L A; Vodnik, Tatjana; Huisman, Willem; Vaubourdolle, Michel
2016-12-01
This document is based on the original recommendation of the Expert Panel on the Theory of Reference Values of the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC), updated guidelines were recently published under the auspices of the IFCC and the Clinical and Laboratory Standards Institute (CLSI). This document summarizes proposals for recommendations on: (i) The terminology, which is often confusing, noticeably concerning the terms of reference limits and decision limits. (ii) The method for the determination of reference limits according to the original procedure and the conditions, which should be used. (iii) A simple procedure allowing the medical laboratories to fulfill the requirements of the regulation and standards. The updated document proposes to verify that published reference limits are applicable to the laboratory involved. Finally, the strengths and limits of the revised recommendations (especially the selection of the reference population, the maintenance of the analytical quality, the choice of the statistical method used…) will be briefly discussed.
Implementation of a National Reference Laboratory for Buruli Ulcer Disease in Togo
Badziklou, Kossi; Halatoko, Wemboo Afiwa; Maman, Issaka; Vogel, Felix; Bidjada, Bawimodom; Awoussi, Koffi Somenou; Piten, Ebekalisai; Helfrich, Kerstin; Mengele, Carolin; Nitschke, Jörg; Amekuse, Komi; Wiedemann, Franz Xaver; Diefenhardt, Adolf; Kobara, Basile; Herbinger, Karl–Heinz; Kere, Abiba Banla; Prince-David, Mireille; Löscher, Thomas; Bretzel, Gisela
2013-01-01
Background In a previous study PCR analysis of clinical samples from suspected cases of Buruli ulcer disease (BUD) from Togo and external quality assurance (EQA) for local microscopy were conducted at an external reference laboratory in Germany. The relatively poor performance of local microscopy as well as effort and time associated with shipment of PCR samples necessitated the implementation of stringent EQA measures and availability of local laboratory capacity. This study describes the approach to implementation of a national BUD reference laboratory in Togo. Methodology Large scale outreach activities accompanied by regular training programs for health care professionals were conducted in the regions “Maritime” and “Central,” standard operating procedures defined all processes in participating laboratories (regional, national and external reference laboratories) as well as the interaction between laboratories and partners in the field. Microscopy was conducted at regional level and slides were subjected to EQA at national and external reference laboratories. For PCR analysis, sample pairs were collected and subjected to a dry-reagent-based IS2404-PCR (DRB-PCR) at national level and standard IS2404 PCR followed by IS2404 qPCR analysis of negative samples at the external reference laboratory. Principal Findings The inter-laboratory concordance rates for microscopy ranged from 89% to 94%; overall, microscopy confirmed 50% of all suspected BUD cases. The inter-laboratory concordance rate for PCR was 96% with an overall PCR case confirmation rate of 78%. Compared to a previous study, the rate of BUD patients with non-ulcerative lesions increased from 37% to 50%, the mean duration of disease before clinical diagnosis decreased significantly from 182.6 to 82.1 days among patients with ulcerative lesions, and the percentage of category III lesions decreased from 30.3% to 19.2%. Conclusions High inter-laboratory concordance rates as well as case confirmation rates of 50% (microscopy), 71% (PCR at national level), and 78% (including qPCR confirmation at external reference laboratory) suggest high standards of BUD diagnostics. The increase of non-ulcerative lesions, as well as the decrease in diagnostic delay and category III lesions, prove the effect of comprehensive EQA and training measures involving also procedures outside the laboratory. PMID:23359828
Implementation of a national reference laboratory for Buruli ulcer disease in Togo.
Beissner, Marcus; Huber, Kristina Lydia; Badziklou, Kossi; Halatoko, Wemboo Afiwa; Maman, Issaka; Vogel, Felix; Bidjada, Bawimodom; Awoussi, Koffi Somenou; Piten, Ebekalisai; Helfrich, Kerstin; Mengele, Carolin; Nitschke, Jörg; Amekuse, Komi; Wiedemann, Franz Xaver; Diefenhardt, Adolf; Kobara, Basile; Herbinger, Karl-Heinz; Kere, Abiba Banla; Prince-David, Mireille; Löscher, Thomas; Bretzel, Gisela
2013-01-01
In a previous study PCR analysis of clinical samples from suspected cases of Buruli ulcer disease (BUD) from Togo and external quality assurance (EQA) for local microscopy were conducted at an external reference laboratory in Germany. The relatively poor performance of local microscopy as well as effort and time associated with shipment of PCR samples necessitated the implementation of stringent EQA measures and availability of local laboratory capacity. This study describes the approach to implementation of a national BUD reference laboratory in Togo. Large scale outreach activities accompanied by regular training programs for health care professionals were conducted in the regions "Maritime" and "Central," standard operating procedures defined all processes in participating laboratories (regional, national and external reference laboratories) as well as the interaction between laboratories and partners in the field. Microscopy was conducted at regional level and slides were subjected to EQA at national and external reference laboratories. For PCR analysis, sample pairs were collected and subjected to a dry-reagent-based IS2404-PCR (DRB-PCR) at national level and standard IS2404 PCR followed by IS2404 qPCR analysis of negative samples at the external reference laboratory. The inter-laboratory concordance rates for microscopy ranged from 89% to 94%; overall, microscopy confirmed 50% of all suspected BUD cases. The inter-laboratory concordance rate for PCR was 96% with an overall PCR case confirmation rate of 78%. Compared to a previous study, the rate of BUD patients with non-ulcerative lesions increased from 37% to 50%, the mean duration of disease before clinical diagnosis decreased significantly from 182.6 to 82.1 days among patients with ulcerative lesions, and the percentage of category III lesions decreased from 30.3% to 19.2%. High inter-laboratory concordance rates as well as case confirmation rates of 50% (microscopy), 71% (PCR at national level), and 78% (including qPCR confirmation at external reference laboratory) suggest high standards of BUD diagnostics. The increase of non-ulcerative lesions, as well as the decrease in diagnostic delay and category III lesions, prove the effect of comprehensive EQA and training measures involving also procedures outside the laboratory.
Make versus buy: a financial perspective.
Kisner, Harold J
2003-01-01
Clinical laboratories are often faced with the decision to either perform a service in-house using their own assets or outsource the service to another vendor. This decision affects many aspects of the laboratory's business, from the macroeconomic perspective of outsourcing the laboratory service to a laboratory vendor, to the microeconomics of determining whether to refer a test out to their reference laboratory or perform the test in-house. The basis for decision making includes many variables, but a detailed financial analysis is usually the basis for the decision, especially when the decision only affects the laboratory and not the rest of the institution. Other factors often come into play, and depending on the magnitude, the "make versus buy" decision could be based more on strategic or political factors than economics. Even when noneconomic factors are involved, an effort usually is made to quantify those factors so that the make versus buy decision is reduced to financial terms. The previous article in this issue, "Effectively Managing Your Reference Laboratory Relationship" by Ronald L. Weiss, M.D., focused on the "buy" decision relating to managing the reference laboratory relationship. Although that article took a more clinical perspective through the eyes of the reference laboratory, this article looks at the make versus buy decision from a financial perspective through the eyes of the buying party.
Shared-resource computing for small research labs.
Ackerman, M J
1982-04-01
A real time laboratory computer network is described. This network is composed of four real-time laboratory minicomputers located in each of four division laboratories and a larger minicomputer in a centrally located computer room. Off the shelf hardware and software were used with no customization. The network is configured for resource sharing using DECnet communications software and the RSX-11-M multi-user real-time operating system. The cost effectiveness of the shared resource network and multiple real-time processing using priority scheduling is discussed. Examples of utilization within a medical research department are given.
Maugat, S; de Rougemont, A; Aubry-Damon, H; Reverdy, M-E; Georges, S; Vandenesch, F; Etienne, J; Coignard, B
2009-05-01
The aim of this study was to estimate the frequency of methicillin-resistant Staphylococcus aureus (MRSA) strains in the French community and the proportion of Panton-Valentine (PVL)-MRSA. A cross-sectional study was made during a 3-month period in 2003 through a network of private-sector, community-based medical laboratories selected throughout France: the Labville network. Each MRSA isolate was included and characterized by French National Reference Center for Staphylococci. The total number of S. aureus isolates was also collected. Among the 283 patients infected or colonized by MRSA, 166 (59%) were considered as healthcare-associated, 14 (5%) as nursing-associated and 39 (14%) as community-acquired. The proportion of methicillin resistance among S. aureus was 14%. Taking into account the sampling design, the incidence of MRSA cases in French outpatients was estimated to be 0.50 [CI95%: 0.41-0.60] per 10,000 inhabitants. The molecular analysis confirmed that 80.6% belong to the Lyon clone, the most prevalent hospital MRSA clone spreading in France and 10.6% to a closely related clone. An emerging MRSA clone containing the tst1 gene was detected in six patients and the PVL-positive ST80 clone only in one, 22-year-old, patient. Most of MRSA cases diagnosed in the community in France, in 2003, were elderly with specific risk factors and harbored hospital strains. The prevalence of PVL-MRSA remained low.
Uptake of recommended common reference intervals for chemical pathology in Australia.
Jones, Graham Rd; Koetsier, Sabrina
2017-05-01
Background Reference intervals are a vital part of reporting numerical pathology results. It is known, however, that variation in reference intervals between laboratories is common, even when analytical methods support common reference intervals. In response to this, in Australia, the Australasian Association of Clinical Biochemists together with the Royal College of Pathologists of Australasia published in 2014 a set of recommended common reference intervals for 11 common serum analytes (sodium, potassium, chloride, bicarbonate, creatinine male, creatinine female, calcium, calcium adjusted for albumin, phosphate, magnesium, lactate dehydrogenase, alkaline phosphatase and total protein). Methods Uptake of recommended common reference intervals in Australian laboratories was assessed using data from four annual cycles of the RCPAQAP reference intervals external quality assurance programme. Results Over three years, from 2013 to 2016, the use of the recommended upper and lower reference limits has increased from 40% to 83%. Nearly half of the intervals in use by enrolled laboratories in 2016 have been changed in this time period, indicating an active response to the guidelines. Conclusions These data support the activities of the Australasian Association of Clinical Biochemists and Royal College of Pathologists of Australasia in demonstrating a change in laboratory behaviour to reduce unnecessary variation in reference intervals and thus provide a consistent message to doctor and patients irrespective of the laboratory used.
Anchor-Free Localization Method for Mobile Targets in Coal Mine Wireless Sensor Networks
Pei, Zhongmin; Deng, Zhidong; Xu, Shuo; Xu, Xiao
2009-01-01
Severe natural conditions and complex terrain make it difficult to apply precise localization in underground mines. In this paper, an anchor-free localization method for mobile targets is proposed based on non-metric multi-dimensional scaling (Multi-dimensional Scaling: MDS) and rank sequence. Firstly, a coal mine wireless sensor network is constructed in underground mines based on the ZigBee technology. Then a non-metric MDS algorithm is imported to estimate the reference nodes’ location. Finally, an improved sequence-based localization algorithm is presented to complete precise localization for mobile targets. The proposed method is tested through simulations with 100 nodes, outdoor experiments with 15 ZigBee physical nodes, and the experiments in the mine gas explosion laboratory with 12 ZigBee nodes. Experimental results show that our method has better localization accuracy and is more robust in underground mines. PMID:22574048
Anchor-free localization method for mobile targets in coal mine wireless sensor networks.
Pei, Zhongmin; Deng, Zhidong; Xu, Shuo; Xu, Xiao
2009-01-01
Severe natural conditions and complex terrain make it difficult to apply precise localization in underground mines. In this paper, an anchor-free localization method for mobile targets is proposed based on non-metric multi-dimensional scaling (Multi-dimensional Scaling: MDS) and rank sequence. Firstly, a coal mine wireless sensor network is constructed in underground mines based on the ZigBee technology. Then a non-metric MDS algorithm is imported to estimate the reference nodes' location. Finally, an improved sequence-based localization algorithm is presented to complete precise localization for mobile targets. The proposed method is tested through simulations with 100 nodes, outdoor experiments with 15 ZigBee physical nodes, and the experiments in the mine gas explosion laboratory with 12 ZigBee nodes. Experimental results show that our method has better localization accuracy and is more robust in underground mines.
A composite CBRN surveillance and testing service
NASA Astrophysics Data System (ADS)
Niemeyer, Debra M.
2004-08-01
The terrorist threat coupled with a global military mission necessitates quick and accurate identification of environmental hazards, and CBRN early warning. The Air Force Institute for Operational Health (AFIOH) provides fundamental support to protect personnel from and mitigate the effects of untoward hazards exposures. Sustaining healthy communities since 1955, the organizational charter is to enhance warfighter mission effectiveness, protect health, improve readiness and reduce costs, assess and manage risks to human heath and safety, operational performance and the environment. The AFIOH Surveillance Directorate provides forward deployed and reach-back surveillance, agent identification, and environ-mental regulatory compliance testing. Three unique laboratories process and analyze over two million environmental samples and clinical specimens per year, providing analytical chemistry, radiological assessment, and infectious disease testing, in addition to supporting Air Force and Department of Defense (DoD) clinical reference laboratory and force health protection testing. Each laboratory has an applied or investigational testing section where new technologies and techniques are evaluated, and expert consultative support to assist in technology assessments and test analyses. The Epidemiology Surveillance Laboratory and Analytical Chemistry Laboratory are critical assets of the Centers for Disease Control and Prevention (CDC) National Laboratory Response Network. Deployable assets provide direct support to the Combatant Commander and include the Air Force Radiological Assessment Team, and the Biological Augmentation Team. A diverse directorate, the synergistic CBRN response capabilities are a commander"s force protection tool, critical to maintaining combat power.
Practical Aspects of Designing and Conducting Validation Studies Involving Multi-study Trials.
Coecke, Sandra; Bernasconi, Camilla; Bowe, Gerard; Bostroem, Ann-Charlotte; Burton, Julien; Cole, Thomas; Fortaner, Salvador; Gouliarmou, Varvara; Gray, Andrew; Griesinger, Claudius; Louhimies, Susanna; Gyves, Emilio Mendoza-de; Joossens, Elisabeth; Prinz, Maurits-Jan; Milcamps, Anne; Parissis, Nicholaos; Wilk-Zasadna, Iwona; Barroso, João; Desprez, Bertrand; Langezaal, Ingrid; Liska, Roman; Morath, Siegfried; Reina, Vittorio; Zorzoli, Chiara; Zuang, Valérie
This chapter focuses on practical aspects of conducting prospective in vitro validation studies, and in particular, by laboratories that are members of the European Union Network of Laboratories for the Validation of Alternative Methods (EU-NETVAL) that is coordinated by the EU Reference Laboratory for Alternatives to Animal Testing (EURL ECVAM). Prospective validation studies involving EU-NETVAL, comprising a multi-study trial involving several laboratories or "test facilities", typically consist of two main steps: (1) the design of the validation study by EURL ECVAM and (2) the execution of the multi-study trial by a number of qualified laboratories within EU-NETVAL, coordinated and supported by EURL ECVAM. The approach adopted in the conduct of these validation studies adheres to the principles described in the OECD Guidance Document on the Validation and International Acceptance of new or updated test methods for Hazard Assessment No. 34 (OECD 2005). The context and scope of conducting prospective in vitro validation studies is dealt with in Chap. 4 . Here we focus mainly on the processes followed to carry out a prospective validation of in vitro methods involving different laboratories with the ultimate aim of generating a dataset that can support a decision in relation to the possible development of an international test guideline (e.g. by the OECD) or the establishment of performance standards.
MSE-impact of PPP-RTK ZTD estimation strategies
NASA Astrophysics Data System (ADS)
Wang, K.; Khodabandeh, A.; Teunissen, P. J. G.
2018-06-01
In PPP-RTK network processing, the wet component of the zenith tropospheric delay (ZTD) cannot be precisely modelled and thus remains unknown in the observation equations. For small networks, the tropospheric mapping functions of different stations to a given satellite are almost equal to each other, thereby causing a near rank-deficiency between the ZTDs and satellite clocks. The stated near rank-deficiency can be solved by estimating the wet ZTD components relatively to that of the reference receiver, while the wet ZTD component of the reference receiver is constrained to zero. However, by increasing network scale and humidity around the reference receiver, enlarged mismodelled effects could bias the network and the user solutions. To consider both the influences of the noise and the biases, the mean-squared errors (MSEs) of different network and user parameters are studied analytically employing both the ZTD estimation strategies. We conclude that for a certain set of parameters, the difference in their MSE structures using both strategies is only driven by the square of the reference wet ZTD component and the formal variance of its solution. Depending on the network scale and the humidity condition around the reference receiver, the ZTD estimation strategy that delivers more accurate solutions might be different. Simulations are performed to illustrate the conclusions made by analytical studies. We find that estimating the ZTDs relatively in large networks and humid regions (for the reference receiver) could significantly degrade the network ambiguity success rates. Using ambiguity-fixed network-derived PPP-RTK corrections, for networks with an inter-station distance within 100 km, the choices of the ZTD estimation strategy is not crucial for single-epoch ambiguity-fixed user positioning. Using ambiguity-float network corrections, for networks with inter-station distances of 100, 300 and 500 km in humid regions (for the reference receiver), the root-mean-squared errors (RMSEs) of the estimated user coordinates using relative ZTD estimation could be higher than those under the absolute case with differences up to millimetres, centimetres and decimetres, respectively.
Robinson, James C; Whaley, Christopher; Brown, Timothy T
2016-09-01
Prices for laboratory and other clinical services vary widely. Employers and insurers increasingly are adopting "reference pricing" policies to create incentives for patients to select lower-priced facilities. To measure the association between implementation of reference pricing and patient choice of laboratory, test prices, patient out-of-pocket spending, and insurer spending. We conducted an observational study of changes in laboratory pricing and selection by employees of a large national grocery firm (n = 30 415) before and after the firm implemented a reference pricing policy for laboratory services and compared the findings with changes over the same period for policy holders of a large national insurer that did not implement reference pricing (n = 181 831). The grocery firm established a maximum payment limit at the 60th percentile of the distribution of prices for each laboratory test in each region. Employees were provided with data on prices at all laboratories through a mobile digital platform. Patients selecting a laboratory that charged more than the payment limit were required to pay the full difference themselves. A total of 2.13 million claims were analyzed for 285 types of in vitro diagnostic tests between 2010 and 2013. Patient choice of laboratory, price paid per test, patient out-of-pocket costs, and employer spending. Compared with trends in prices paid by insurance policy holders not subject to reference pricing, and after adjusting for characteristics of tests and patients, implementation of reference pricing was associated with a 31.9% reduction (95% CI, 20.6%-41.6%) in average price paid per test by the third year of the program. In these 3 years, total spending on laboratory tests declined by $2.57 million (95% CI, $1.59-$3.35 million). Out-of-pocket costs by patients declined by $1.05 million (95% CI, $0.73-$1.37 million). Spending by the employer declined by $1.70 million (95% CI, $0.92-$2.48 million). When combined with access to price information, reference pricing was associated with patient choice of lower-cost laboratories and reductions in prices and payments by both employer and employees.
A review of international biobanks and networks: success factors and key benchmarks.
Vaught, Jim; Kelly, Andrea; Hewitt, Robert
2009-09-01
Biobanks and biobanking networks are involved in varying degrees in the collection, processing, storage, and dissemination of biological specimens. This review outlines the approaches that 16 of the largest biobanks and biobanking networks in Europe, North America, Australia, and Asia have taken to collecting and distributing human research specimens and managing scientific initiatives while covering operating costs. Many are small operations that exist as either a single or a few freezers in a research laboratory, hospital clinical laboratory, or pathology suite. Larger academic and commercial biobanks operate to support large clinical and epidemiological studies. Operational and business models depend on the medical and research missions of their institutions and home countries. Some national biobanks operate with a centralized physical biobank that accepts samples from multiple locations. Others operate under a "federated" model where each institution maintains its own collections but agrees to list them on a central shared database. Some collections are "project-driven" meaning that specimens are collected and distributed to answer specific research questions. "General" collections are those that exist to establish a reference collection, that is, not to meet particular research goals but to be available to respond to multiple requests for an assortment of research uses. These individual and networked biobanking systems operate under a variety of business models, usually incorporating some form of partial cost recovery, while requiring at least partial public or government funding. Each has a well-defined biospecimen-access policy in place that specifies requirements that must be met-such as ethical clearance and the expertise to perform the proposed experiments-to obtain samples for research. The success of all of these biobanking models depends on a variety of factors including well-defined goals, a solid business plan, and specimen collections that are developed according to strict quality and operational controls.
Roles of laboratories and laboratory systems in effective tuberculosis programmes.
Ridderhof, John C; van Deun, Armand; Kam, Kai Man; Narayanan, P R; Aziz, Mohamed Abdul
2007-05-01
Laboratories and laboratory networks are a fundamental component of tuberculosis (TB) control, providing testing for diagnosis, surveillance and treatment monitoring at every level of the health-care system. New initiatives and resources to strengthen laboratory capacity and implement rapid and new diagnostic tests for TB will require recognition that laboratories are systems that require quality standards, appropriate human resources, and attention to safety in addition to supplies and equipment. To prepare the laboratory networks for new diagnostics and expanded capacity, we need to focus efforts on strengthening quality management systems (QMS) through additional resources for external quality assessment programmes for microscopy, culture, drug susceptibility testing (DST) and molecular diagnostics. QMS should also promote development of accreditation programmes to ensure adherence to standards to improve both the quality and credibility of the laboratory system within TB programmes. Corresponding attention must be given to addressing human resources at every level of the laboratory, with special consideration being given to new programmes for laboratory management and leadership skills. Strengthening laboratory networks will also involve setting up partnerships between TB programmes and those seeking to control other diseases in order to pool resources and to promote advocacy for quality standards, to develop strategies to integrate laboratories functions and to extend control programme activities to the private sector. Improving the laboratory system will assure that increased resources, in the form of supplies, equipment and facilities, will be invested in networks that are capable of providing effective testing to meet the goals of the Global Plan to Stop TB.
Olivari, Z; Piccolo, E
2001-01-01
In the last few years we have witnessed a substantial growth in the number of catheterization laboratories, especially in the northern regions of Italy, a phenomenon which has met some controversy and has been discussed in a Symposium at the ANMCO National Conference (Florence, May 20-23, 2000). The controversy is essentially between those who believe in the implementation of catheterization laboratories in all cardiology units equipped with a cardiological intensive care unit (and the creation of a functional network with the tutorial centers) and those who refer to the existing guidelines, standards and VRQ which envisage a geographical distribution of laboratories on the basis of a balance between needs of the population and the minimum quantity of procedures performed by each center in order to guarantee the best quality and cost-effectiveness. The aim of the Symposium was to clarify whether the two "innovations" of these last few years, namely the introduction of new portable radiological equipment on the one hand and the effectiveness of primary angioplasty in the treatment of acute myocardial infarction on the other, may influence the redefinition of criteria regarding the distribution of laboratories, taking into account as well the expansion of indications for coronary angioplasty and coronary angiography. After a lively discussion, the proceedings can be summed up as follows: no agreement was reached regarding the role of portable radiological equipment in the decisional process regarding the setting up of a new catheterization laboratory; primary angioplasty should be carried out in centers with an adequate volume of activity and a functioning inter-hospital organizational structure for this demanding activity; otherwise it does not offer any advantages over fibrinolytic therapy; the proposal of a new organizational model is based on the creation of transverse inter-hospital cardiology departments, the size of which is based on the overall size of the user population, with interventional laboratories distributed in the reference hospitals and diagnostic laboratories in hospitals equipped with a cardiologic intensive care unit (where there is a sufficiently large user population to guarantee at least the minimum number of procedures envisaged by the standards); both parts should work in close cooperation. On this last point there was a contrasting opinion and it was not possible to reach a consensus. The Scientific Societies should formally express their views on this controversial topic, so that guidelines, standards and VRQ can be updated rapidly. The latter should constitute the reference for the procedures of accreditation to which all laboratories and cardiology departments are subjected to, and it is likely that this will be the best way to overcome the present controversy.
Fukushima, Kazuyuki; Miura, Yuji; Sawada, Kohei; Yamazaki, Kazuto; Ito, Masashi
2016-01-01
Using human cell models mimicking the central nervous system (CNS) provides a better understanding of the human CNS, and it is a key strategy to improve success rates in CNS drug development. In the CNS, neurons function as networks in which astrocytes play important roles. Thus, an assessment system of neuronal network functions in a co-culture of human neurons and astrocytes has potential to accelerate CNS drug development. We previously demonstrated that human hippocampus-derived neural stem/progenitor cells (HIP-009 cells) were a novel tool to obtain human neurons and astrocytes in the same culture. In this study, we applied HIP-009 cells to a multielectrode array (MEA) system to detect neuronal signals as neuronal network functions. We observed spontaneous firings of HIP-009 neurons, and validated functional formation of neuronal networks pharmacologically. By using this assay system, we investigated effects of several reference compounds, including agonists and antagonists of glutamate and γ-aminobutyric acid receptors, and sodium, potassium, and calcium channels, on neuronal network functions using firing and burst numbers, and synchrony as readouts. These results indicate that the HIP-009/MEA assay system is applicable to the pharmacological assessment of drug candidates affecting synaptic functions for CNS drug development. © 2015 Society for Laboratory Automation and Screening.
van Kampen, Sanne C.; Oskam, Linda; Tuijn, Coosje J.; Klatser, Paul R.
2012-01-01
Background Successful integration of new diagnostics in national tuberculosis (TB) control programs, also called ‘retooling’, is highly dependent on operational aspects related to test availability, accessibility and affordability. This survey aimed to find out whether recommendations to use new diagnostics lead to successful retooling in high TB endemic countries, using immunochromatographic tests (ICTs) for TB culture speciation as a case study. ICTs are recommended to accurately confirm the presence of bacteria of the Mycobacterium tuberculosis complex in liquid culture isolates. Methods and Findings Questionnaires were sent to national TB reference laboratories (NRLs) in 42 high TB endemic countries to address their access to information on ICT implementation, logistics related to availability, accessibility and affordability of ICTs, and testing algorithms. Results from 16 responding countries indicated that half of the NRLs were aware of the contents of WHO guidance documents on liquid culture and ICT implementation, as well as their eligibility for a negotiated pricing agreement for ICT procurement. No major issues with availability and accessibility of ICTs were raised. When asked about testing algorithms, ICTs were not used as stand-alone or first test for TB culture identification as recommended by WHO. Conclusions The low response rate was a limitation of this survey and together with NRLs managers' unawareness of global guidance, suggests a lack of effective communication between partners of the global laboratory network and NRLs. TB tests could become more affordable to high TB endemic countries, if the possibility to negotiate lower prices for commercial products is communicated to them more successfully. NRLs need additional guidance to identify where available technologies can be most usefully implemented and in what order, taking into account long-term laboratory strategies. PMID:22937050
Localization Strategies in WSNs as applied to Landslide Monitoring (Invited)
NASA Astrophysics Data System (ADS)
Massa, A.; Robol, F.; Polo, A.; Giarola, E.; Viani, F.
2013-12-01
In the last years, heterogeneous integrated smart systems based on wireless sensor network (WSN) technology have been developed at the ELEDIA Research Center of the University of Trento [1]. One of the key features of WSNs as applied to distributed monitoring is that, while the capabilities of each single sensor node is limited, the implementation of cooperative schemes throughout the whole network enables the solution of even complex tasks, as the landslide monitoring. The capability of localizing targets respect to the position of the sensor nodes turns out to be fundamental in those application fields where relative movements arise. The main properties like the target typology, the movement characteristics, and the required localization resolution are different changing the reference scenario. However, the common key issue is still the localization of moving targets within the area covered by the sensor network. Many experiences were preparatory for the challenging activities in the field of landslide monitoring where the basic idea is mostly that of detecting slight soil movements. Among them, some examples of WSN-based systems experimentally applied to the localization of people [2] and wildlife [3] have been proposed. More recently, the WSN backbone as well as the investigated sensing technologies have been customized for monitoring superficial movements of the soil. The relative positions of wireless sensor nodes deployed where high probability of landslide exists is carefully monitored to forecast dangerous events. Multiple sensors like ultrasound, laser, high precision GPS, for the precise measurement of relative distances between the nodes of the network and the absolute positions respect to reference targets have been integrated in a prototype system. The millimeter accuracy in the position estimation enables the detection of small soil modifications and to infer the superficial evolution profile of the landslide. This information locally acquired also represent a fine tuning of large scale satellite acquisitions, usually adopted for remote sensing of landslides. The integration of dense and frequent WSN data within satellite image analysis will enhance the sensing capabilities leading to a multi-resolution and an highly space-time calibrated system. The WSN-based system has been preliminary tested in controlled environments in the ELEDIA laboratories and is now installed in a real test site where an active landslide is evolving. Preliminary data are here presented to assess the feasibility of the investigated solution in landslide monitoring and event forecasting. REFERENCES [1] M. Benedetti, L. Ioriatti, M. Martinelli, and F. Viani, 'Wireless sensor network: a pervasive technology for earth observation,' in IEEE Journal of Selected Topics in App. Earth Obs. And Remote Sens., vol. 3, no. 4, pp. 488-497, 2010. [2] F. Viani, M. Donelli, P. Rocca, G. Oliveri, D. Trinchero, and A. Massa, 'Localization, tracking and imaging of targets in wireless sensor networks,' Radio Science, vol. 46, no. 5, 2011. [3] F. Viani, F. Robol, M. Salucci, E. Giarola, S. De Vigili, M. Rocca, F. Boldrini, G. Benedetti, and A. Massa, 'WSN-based early alert system for preventing wildlife-vehicle collisions in Alps regions - From the laboratory test to the real-world implementation,' 7th European Conference on Antennas and Propagation 2013 (EUCAP2013), Gothenburg, Sweden, April 8-12, 2013.
Drinking Water and Wastewater Laboratory Networks
This website provides the drinking water sector with an integrated nationwide network of laboratories with the analytical capability to respond to intentional and unintentional drinking water incidents.
Cloud-Based Virtual Laboratory for Network Security Education
ERIC Educational Resources Information Center
Xu, Le; Huang, Dijiang; Tsai, Wei-Tek
2014-01-01
Hands-on experiments are essential for computer network security education. Existing laboratory solutions usually require significant effort to build, configure, and maintain and often do not support reconfigurability, flexibility, and scalability. This paper presents a cloud-based virtual laboratory education platform called V-Lab that provides a…
2016-06-01
ARL-TR-7698 ● JUNE 2016 US Army Research Laboratory Human -Systems Integration (HSI) and the Network Integration Evaluations...ARL-TR-7698 ● JUNE 2016 US Army Research Laboratory Human -Systems Integration (HSI) and the Network Integration Evaluations (NIEs), Part 3...Mitigating Cognitive Load in Network-Enabled Mission Command by John K Hawley Human Research and Engineering Directorate, ARL Michael W
75 FR 9900 - Agency Forms Undergoing Paperwork Reduction Act Review
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-04
... ability of the Network to respond to a biological or chemical terrorism event. The sensitivity of all... Project Laboratory Response Network (LRN)--Existing Data Collection in use without an OMB Control Number... Disease Control and Prevention (CDC). Background and Brief Description The Laboratory Response Network...
An artificial neural network system to identify alleles in reference electropherograms.
Taylor, Duncan; Harrison, Ash; Powers, David
2017-09-01
Electropherograms are produced in great numbers in forensic DNA laboratories as part of everyday criminal casework. Before the results of these electropherograms can be used they must be scrutinised by analysts to determine what the identified data tells them about the underlying DNA sequences and what is purely an artefact of the DNA profiling process. This process of interpreting the electropherograms can be time consuming and is prone to subjective differences between analysts. Recently it was demonstrated that artificial neural networks could be used to classify information within an electropherogram as allelic (i.e. representative of a DNA fragment present in the DNA extract) or as one of several different categories of artefactual fluorescence that arise as a result of generating an electropherogram. We extend that work here to demonstrate a series of algorithms and artificial neural networks that can be used to identify peaks on an electropherogram and classify them. We demonstrate the functioning of the system on several profiles and compare the results to a leading commercial DNA profile reading system. Copyright © 2017 Elsevier B.V. All rights reserved.
Influenza and the work of the World Health Organization.
Kitler, M E; Gavinio, P; Lavanchy, D
2002-05-15
Before World War I, influenza was not considered a particularly serious problem. The great pandemic of 1918-1919 changed all that, and the possibility that such a catastrophe could occur again has conditioned all subsequent developments. In epidemiological terms, the hallmark of an influenza is the excess mortality that it causes combined with an enormous burden of ill-health that saps the energy of individuals, families and communities throughout the whole world. In order to engage in influenza prevention and control, the global influenza surveillance network was set up by World Health Organization (WHO) in 1948 as a worldwide alert system for the identification of new influenza viruses, gathering information from 110 participating laboratories in 82 countries and four WHO Collaborating Centers for Influenza reference and research: Centers for Disease Control and Prevention, Atlanta (USA), National Institute for Medical Research, London (UK), WHO Collaborating Centre for Influenza Reference and Research, Melbourne (Australia) and the National Institute for Infectious Diseases, Tokyo (Japan). This network helps WHO to monitor influenza activity all over the world and provides the organization with the viral isolates and information it requires to decide which new virus strains will be used to produce influenza vaccines during the following season. Each year, information about the isolates over the previous 12 months is analyzed and used to determine the composition of the influenza vaccine to be administered during the coming influenza season both for the northern and southern hemisphere. If necessary, the recommendations for the southern hemisphere differ from the ones formulated for the northern hemisphere vaccine. The information supplied by this network enables the organization to regularly update its World Wide Web (WWW) site (FluNet), which reports on the situation of diseases. This network will also enable the WHO to detect a new influenza pandemic as early as possible.
Long, H. Keith; Daddow, Richard L.; Farrar, Jerry W.
1998-01-01
Since 1962, the U.S. Geological Survey (USGS) has operated the Standard Reference Sample Project to evaluate the performance of USGS, cooperator, and contractor analytical laboratories that analyze chemical constituents of environmental samples. The laboratories are evaluated by using performance evaluation samples, called Standard Reference Samples (SRSs). SRSs are submitted to laboratories semi-annually for round-robin laboratory performance comparison purposes. Currently, approximately 100 laboratories are evaluated for their analytical performance on six SRSs for inorganic and nutrient constituents. As part of the SRS Project, a surplus of homogeneous, stable SRSs is maintained for purchase by USGS offices and participating laboratories for use in continuing quality-assurance and quality-control activities. Statistical evaluation of the laboratories results provides information to compare the analytical performance of the laboratories and to determine possible analytical deficiences and problems. SRS results also provide information on the bias and variability of different analytical methods used in the SRS analyses.
[On the way to national reference system of laboratory medicine].
Muravskaia, N P; Men'shikov, V V
2014-10-01
The application of standard samples and reference techniques of implementation of measurements is needed for a valid support of reliability of analyses applied in clinical diagnostic laboratories. They play role of landmarks under metrologic monitoring, calibration of devices and control of quality of results. The article presents analysis of shortcomings interfering with formation of national reference system in Russia harmonized with possibilities provided by international organizations. Among them are the joint Committee on metrologic monitoring in laboratory medicine under the auspices of the International Bureau of Weights and Measures, the International Federation of clinical chemistry and laboratory medicine, etc. The results of the recent development of national normative documents, standard samples and techniques assisted by the authors of article are considered. They are the first steps to organization of national reference system which would comprise all range of modern analytical technologies of laboratory medicine. The national and international measures are proposed to enhance the promptest resolving of task of organization of national reference system for laboratory medicine in the interests of increasing of effectiveness of medical care to citizen of Russia.
Makretsov, Nikita; Gilks, C Blake; Alaghehbandan, Reza; Garratt, John; Quenneville, Louise; Mercer, Joel; Palavdzic, Dragana; Torlakovic, Emina E
2011-07-01
External quality assurance and proficiency testing programs for breast cancer predictive biomarkers are based largely on traditional ad hoc design; at present there is no universal consensus on definition of a standard reference value for samples used in external quality assurance programs. To explore reference values for estrogen receptor and progesterone receptor immunohistochemistry in order to develop an evidence-based analytic platform for external quality assurance. There were 31 participating laboratories, 4 of which were previously designated as "expert" laboratories. Each participant tested a tissue microarray slide with 44 breast carcinomas for estrogen receptor and progesterone receptor and submitted it to the Canadian Immunohistochemistry Quality Control Program for analysis. Nuclear staining in 1% or more of the tumor cells was a positive score. Five methods for determining reference values were compared. All reference values showed 100% agreement for estrogen receptor and progesterone receptor scores, when indeterminate results were excluded. Individual laboratory performance (agreement rates, test sensitivity, test specificity, positive predictive value, negative predictive value, and κ value) was very similar for all reference values. Identification of suboptimal performance by all methods was identical for 30 of 31 laboratories. Estrogen receptor assessment of 1 laboratory was discordant: agreement was less than 90% for 3 of 5 reference values and greater than 90% with the use of 2 other reference values. Various reference values provide equivalent laboratory rating. In addition to descriptive feedback, our approach allows calculation of technical test sensitivity and specificity, positive and negative predictive values, agreement rates, and κ values to guide corrective actions.
NASA Astrophysics Data System (ADS)
Ozdagli, A. I.; Liu, B.; Moreu, F.
2018-07-01
According to railroad managers, displacement of railroad bridges under service loads is an important parameter in the condition assessment and performance evaluation. However, measuring bridge responses in the field is often costly and labor-intensive. This paper proposes a low-cost, efficient wireless intelligent sensor (LEWIS) platform that can compute in real-time the dynamic transverse displacements of railroad bridges under service loads. This sensing platform drives on an open-source Arduino ecosystem and combines low-cost microcontrollers with affordable accelerometers and wireless transmission modules. The proposed LEWIS system is designed to reconstruct dynamic displacements from acceleration measurements onboard, eliminating the need for offline post-processing, and to transmit the data in real-time to a base station where the inspector at the bridge can see the displacements while the train is crossing, or to a remote office if so desired by internet. Researchers validated the effectiveness of the new LEWIS by conducting a series of laboratory experiments. A shake table setup simulated transverse bridge displacements measured on the field and excited the proposed platform, a commercially available wired expensive accelerometer, and reference LVDT displacement sensor. The responses obtained from the wireless system were compared to the displacements reconstructed from commercial accelerometer readings and the reference LVDT. The results of the laboratory experiments demonstrate that the proposed system is capable of reconstructing transverse displacements of railroad bridges under revenue service traffic accurately and transmitting the data in real-time wirelessly. In conclusion, the platform presented in this paper can be used in the performance assessment of railroad bridge network cost-effectively and accurately. Future work includes collecting real-time reference-free displacements of one railroad bridge in Colorado under train crossings to further prove LEWIS' suitability for engineering applications.
Design Automation in Synthetic Biology.
Appleton, Evan; Madsen, Curtis; Roehner, Nicholas; Densmore, Douglas
2017-04-03
Design automation refers to a category of software tools for designing systems that work together in a workflow for designing, building, testing, and analyzing systems with a target behavior. In synthetic biology, these tools are called bio-design automation (BDA) tools. In this review, we discuss the BDA tools areas-specify, design, build, test, and learn-and introduce the existing software tools designed to solve problems in these areas. We then detail the functionality of some of these tools and show how they can be used together to create the desired behavior of two types of modern synthetic genetic regulatory networks. Copyright © 2017 Cold Spring Harbor Laboratory Press; all rights reserved.
Environmental Response Laboratory Network (ERLN) Data Submission Requirements
These Environmental Response Laboratory Network specifications are essential to the mission of providing consistent analytical data of know and documented quality for each Analytical Service Request (ASR).
78 FR 14094 - Agency Forms Undergoing Paperwork Reduction Act Review
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-04
... Program Office to determine the ability of the Network to respond to a biological or chemical threat event... comments should be received within 30 days of this notice. Proposed Project Laboratory Response Network... Laboratory Response Network (LRN) was established by the Department of Health and Human Services (HHS...
78 FR 72087 - Proposed Data Collections Submitted for Public Comment and Recommendations
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-02
... days of this notice. Proposed Project Data Calls for the Laboratory Response Network (0920-0881... Response Network (LRN) was established by the Department of Health and Human Services, Centers for Disease... LRN's mission is to maintain an integrated national and international network of laboratories that can...
78 FR 306 - Proposed Data Collections Submitted for Public Comment and Recommendations
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-03
... Network to respond to a biological or chemical threat event. The sensitivity of all information associated... this notice. Proposed Project Laboratory Response Network (LRN) (OMB No. 0920-0850, Exp. 5/31/ 2013... Prevention (CDC). Background and Brief Description The Laboratory Response Network (LRN) was established by...
75 FR 70929 - Agency Forms Undergoing Paperwork Reduction Act Review
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-19
... Project Data Calls for the Laboratory Response Network--Existing collection in use without an OMB Control... Response Network (LRN) was established by the Department of Health and Human Services, Centers for Disease... LRN's mission is to maintain an integrated national and international network of laboratories that can...
Optimization of multilayer neural network parameters for speaker recognition
NASA Astrophysics Data System (ADS)
Tovarek, Jaromir; Partila, Pavol; Rozhon, Jan; Voznak, Miroslav; Skapa, Jan; Uhrin, Dominik; Chmelikova, Zdenka
2016-05-01
This article discusses the impact of multilayer neural network parameters for speaker identification. The main task of speaker identification is to find a specific person in the known set of speakers. It means that the voice of an unknown speaker (wanted person) belongs to a group of reference speakers from the voice database. One of the requests was to develop the text-independent system, which means to classify wanted person regardless of content and language. Multilayer neural network has been used for speaker identification in this research. Artificial neural network (ANN) needs to set parameters like activation function of neurons, steepness of activation functions, learning rate, the maximum number of iterations and a number of neurons in the hidden and output layers. ANN accuracy and validation time are directly influenced by the parameter settings. Different roles require different settings. Identification accuracy and ANN validation time were evaluated with the same input data but different parameter settings. The goal was to find parameters for the neural network with the highest precision and shortest validation time. Input data of neural networks are a Mel-frequency cepstral coefficients (MFCC). These parameters describe the properties of the vocal tract. Audio samples were recorded for all speakers in a laboratory environment. Training, testing and validation data set were split into 70, 15 and 15 %. The result of the research described in this article is different parameter setting for the multilayer neural network for four speakers.
Wludarski, Sheila Cristina Lordelo; Lopes, Lisandro Ferreira; Duarte, Ivison Xavier; Carvalho, Filomena Marino; Weiss, Lawrence; Bacchi, Carlos Eduardo
2011-01-01
Breast cancer accounts for approximately one quarter of all cancers in females. Estrogen and progesterone receptor testing has become an essential part of the clinical evaluation of breast carcinoma patients, and accurate results are critical in identifying patients who may benefit from hormone therapy. The present study had the aim of investigating the concordance of the results from hormone receptor tests between a reference laboratory and local (or community) laboratories in Brazil. Retrospective study at a reference pathology laboratory. The concordance in the results from hormone receptor tests between a reference laboratory and 146 local laboratories in Brazil was compared in relation to 500 invasive breast carcinoma cases, using immunohistochemistry. There was concordance in 89.4% (447/500 cases) and 85.0% (425/500 cases) of the results from estrogen (κ = 0.744, P < 0.001) and progesterone (κ = 0.688, P < 0.001) receptor tests, respectively, between local and reference laboratories. This was similar to findings in other countries. The false negative rates from estrogen and progesterone receptor tests in local laboratories were 8.7% and 14.4%, respectively. The false positive rates from estrogen and progesterone receptor tests in local laboratories were 15.5% and 16.0%, respectively. Technical and result interpretation issues may explain most of the discordances in hormone receptor testing in local laboratories. Validation of estrogen and progesterone receptor tests at local laboratories, with rigorous quality control measures, is strongly recommended in order to avoid erroneous treatment of breast cancer patients.
Zhou, Yong-ming; Chen, Xiu-hua; Xu, Wen; Jin, Hui-ming; Li, Chao-qun; Liang, Wei-li; Wang, Duo-chun; Yan, Mei-ying; Lou, Jing; Kan, Biao; Ran, Lu; Cui, Zhi-gang; Wang, Shu-kun; Xu, Xue-bin
2013-11-01
To evaluated the fundamental role of stage control technology (SCT) on the detectability for Salmonella networking laboratories. Appropriate Salmonella detection methods after key point control being evaluated, were establishment and optimized. Our training and evaluation networking laboratories participated in the World Health Organization-Global Salmonella Surveillance Project (WHO-GSS) and China-U.S. Collaborative Program on Emerging and Re-emerging infectious diseases Project (GFN) in Shanghai. Staff members from the Yunnan Yuxi city Center for Disease Control and Prevention were trained on Salmonella isolation from diarrhea specimens. Data on annual Salmonella positive rates was collected from the provincial-level monitoring sites to be part of the GSS and GFN projects from 2006 to 2012. The methodology was designed based on the conventional detection procedure of Salmonella which involved the processes as enrichment, isolation, species identification and sero-typing. These methods were simultaneously used to satisfy the sensitivity requirements on non-typhoid Salmonella detection for networking laboratories. Public Health Laboratories in Shanghai had developed from 5 in 2006 to 9 in 2011, and Clinical laboratories from 8 to 22. Number of clinical isolates, including typhoid and non-typhoid Salmonella increased from 196 in 2006 to 1442 in 2011. The positive rate of Salmonella isolated from the clinical diarrhea cases was 2.4% in Yuxi county, in 2012. At present, three other provincial monitoring sites were using the SBG technique as selectivity enrichment broth for Salmonella isolation, with Shanghai having the most stable positive baseline. The method of SCT was proved the premise of the network laboratory construction. Based on this, the improvement of precise phenotypic identification and molecular typing capabilities could reach the level equivalent to the national networking laboratory.
Macarthur, Roy; Feinberg, Max; Bertheau, Yves
2010-01-01
A method is presented for estimating the size of uncertainty associated with the measurement of products derived from genetically modified organisms (GMOs). The method is based on the uncertainty profile, which is an extension, for the estimation of uncertainty, of a recent graphical statistical tool called an accuracy profile that was developed for the validation of quantitative analytical methods. The application of uncertainty profiles as an aid to decision making and assessment of fitness for purpose is also presented. Results of the measurement of the quantity of GMOs in flour by PCR-based methods collected through a number of interlaboratory studies followed the log-normal distribution. Uncertainty profiles built using the results generally give an expected range for measurement results of 50-200% of reference concentrations for materials that contain at least 1% GMO. This range is consistent with European Network of GM Laboratories and the European Union (EU) Community Reference Laboratory validation criteria and can be used as a fitness for purpose criterion for measurement methods. The effect on the enforcement of EU labeling regulations is that, in general, an individual analytical result needs to be < 0.45% to demonstrate compliance, and > 1.8% to demonstrate noncompliance with a labeling threshold of 0.9%.
Laboratory practice at the periphery in developing countries.
Lewis, S M
2002-08-01
An effective national health service structure requires a comprehensive programme for primary health care in peripheral and rural areas. This is especially important in under-resourced countries where facilities are sparse, the population is widely dispersed and transport is limited. Haematology has a key role in diagnosis and patient management by selecting tests for their clinical relevance and utility for the specific circumstances, and ensuring their technical reliability when used in health clinics and point-of-care testing. WHO has proposed a basic menu of tests in three categories: (a) tests such as haemoglobin screen which can be performed by nurses, midwives, health-aides or community doctors, (b) tests such as haemoglobinometry, microhaematocrit and microscopic examination of stained preparations which can be performed by a technician or laboratory assistant in a health centre, (c) tests requiring greater technical expertise of a laboratory technician or trained doctor. The peripheral health clinics and district laboratories must be familiar with the guidelines on standardized methods for collecting and storing specimens and transporting them to a regional laboratory or a reference centre. A training syllabus should be provided at the health centres and district laboratories, and this should include on-site instruction from supervisors and access to training manuals and distance-learning material. A co-ordinated programme of quality assurance and standardization of test methods should be established by a reference centre or national health authority with a network which encompasses all laboratories and health clinics undertaking any tests. Each regional laboratory should foster lower level laboratories or clinics within its neighbourhood. Of particular concern is the reliable diagnosis and management of anaemia. WHO reports indicate that 40% of the world population suffer from anaemia, especially affecting pregnant women, and a high proportion of infants and children in developing countries. The Haemoglobin Colour Scale (HCS) was recently developed for WHO as a simple, cheap and portable device which reads haemoglobin within 1 g/dl of the true value. It has been validated in a number of studies and is now manufactured commercially in accordance with WHO specifications under control of a WHO Collaborating Centre. It has an important potential role in the resource-limited environment where anaemia screening presently usually depends on unreliable clinical examination.
Kebede, Yenew; Fonjungo, Peter N; Tibesso, Gudeta; Shrivastava, Ritu; Nkengasong, John N; Kenyon, Thomas; Kebede, Amha; Gadde, Renuka; Ayana, Gonfa
2016-04-15
Nonstandardized specimen-transport logistics, lack of laboratory personnel to transport specimens, lack of standard specimen containers, and long turnaround time (TAT) hindered access to quality laboratory services. The objective of the Becton, Dickinson, and Company (BD)-US President's Emergency Plan for AIDS Relief (PEPFAR) Public-Private Partnership (PPP) was to support country-specific programs to develop integrated laboratory systems, services, and quality improvement strategies, with an emphasis on strengthening the specimen-referral system (SRS). In 2007, through the Centers for Disease Control and Prevention (CDC), the Ethiopian Public Health Institute (EPHI) joined with the BD-PEPFAR PPP to strengthen laboratory systems. A joint planning and assessment committee identified gaps in the SRS for prioritization and intervention and piloted the system in Addis Ababa and Amhara Region. The PPP established standardized, streamlined specimen logistics, using the Ethiopian Postal Service Enterprise to support a laboratory network in which 554 facilities referred specimens to 160 laboratories. The PPP supported procuring 400 standard specimen containers and the training of 586 laboratory personnel and 81 postal workers. The average TAT was reduced from 7 days (range, 2-14 days) to 2 days (range, 1-3 days) in Addis Ababa and from 10 days (range, 6-21 days) to 5 days (range, 2-6 days) in Amhara Region. This study highlights the feasibility and untapped potential of PPPs to strengthen laboratory systems. This planned and structured approach to improving specimen referral enhanced access to quality laboratory services. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.
``Planetário e Teatro Digital Johannes Kepler'' and its Institutional Pedagogical Project
NASA Astrophysics Data System (ADS)
Faria, R. Z.; Calil, M. R.; Perez, E. R.; Kanashiro, M.; Silva, L. C. P.; Calipo, F.
2014-10-01
This work relates the reception of schools, started on August 2012, in the astronomic laboratory of the "Planetário e Teatro Digital Johannes Kepler", located in the "Sabina - Escola Parque do Conhecimento" in Santo André, São Paulo. The idealization of this project, authorship of Marcos Calil, PhD, consists in four apprenticeship environments disposed around the planetary dome. They make reference to the System Sun - Earth - Moon (Tellurium), Solar System, Astronautic and Stars. On Tuesdays and Wednesdays the astronomic laboratory is used by Santo André municipal schools for focused lessons, being possible on Thursdays scheduling for private and public schools. On weekends and holidays is opened for the visitors. Since the inauguration to the beginning of activities with students, the monitor team was guided and trained on contents of Astronomy and Aeronautic to execute the schools service. This is done in four stages, which are: reception, course trough the astronomic laboratory, dome session and activities closure. During the reception the acquaintance rules are passed on for a better visit. Before starting the course the monitors do a survey about the previous knowledge of the students. On the astronomic laboratory resources of the environment are used to explain the contents of Astronomy and Astronautic, always considering the age group and the curriculum developed in classroom. After the course the students watch a planetary session supporting the contents seen on the astronomic laboratory. At the end a feedback is done with the students about the subject discussed. During the visit the teachers fulfill an evaluation about the place and the service. From August 2012 to November 2012 were attended between municipal, public and private schools. From the 4932 students attended, 92% belonged to the municipal network, 5% to the private network and 3% to the public network. From the 189 evaluations done by the teachers, 97.8% were satisfied, 2.1% partially satisfied e 0.1% unsatisfied with the reception promoted by the team of the planetary. Meantime the satisfaction presented on the evaluation is thought that the use of non-formal places is an ally of apprenticeship. The ``Planetário e Teatro Digital Johannes Kepler'' by its team collaborates for an education and divulgation of the Astronomy and Astronautic make part of the reality and quotidian of the students of the city of Santo André.
Challenges of measles and rubella laboratory diagnostic in the era of elimination.
Hübschen, J M; Bork, S M; Brown, K E; Mankertz, A; Santibanez, S; Ben Mamou, M; Mulders, M N; Muller, C P
2017-08-01
The Member States of the WHO European Region adopted the goal of measles and rubella elimination more than 10 years ago, but so far only 21 of 53 countries have reached this target. Laboratory investigation of suspected cases is essential to support disease elimination efforts. Therefore, WHO maintains a network of accredited laboratories providing high-quality testing. Laboratory investigation heavily relies on specific IgM serology and increasingly on virus detection by reverse transcription (RT)-PCR, but other methods such as IgG avidity testing and genetic characterization of virus strains have gained in importance. In elimination settings, often few samples from suspected cases are available for testing, but testing proficiency must be maintained. The predictive value of an IgM-positive result decreases and other rash-fever disease aetiologies become more important. In addition, cases with a rash after measles/rubella vaccination or with mild disease after waning of vaccine-induced antibodies are seen more often. Thus, it is necessary to perform comprehensive and potentially time-consuming and costly investigations of every suspected case using quality-controlled laboratory methods. At the same time rapid feedback to public health officers is required for timely interventions. The introduction of new laboratory methods for comprehensive case investigations requires training of staff under the supervision of WHO-accredited reference laboratories and the definition of appropriate test algorithms. Clinical, laboratory, and epidemiological data are essential for final case classification and investigation of chains of transmission in the endgame of measles and rubella elimination. Copyright © 2017 European Society of Clinical Microbiology and Infectious Diseases. All rights reserved.
Aarsand, Aasne K; Villanger, Jørild H; Støle, Egil; Deybach, Jean-Charles; Marsden, Joanne; To-Figueras, Jordi; Badminton, Mike; Elder, George H; Sandberg, Sverre
2011-11-01
The porphyrias are a group of rare metabolic disorders whose diagnosis depends on identification of specific patterns of porphyrin precursor and porphyrin accumulation in urine, blood, and feces. Diagnostic tests for porphyria are performed by specialized laboratories in many countries. Data regarding the analytical and diagnostic performance of these laboratories are scarce. We distributed 5 sets of multispecimen samples from different porphyria patients accompanied by clinical case histories to 18-21 European specialist porphyria laboratories/centers as part of a European Porphyria Network organized external analytical and postanalytical quality assessment (EQA) program. The laboratories stated which analyses they would normally have performed given the case histories and reported results of all porphyria-related analyses available, interpretative comments, and diagnoses. Reported diagnostic strategies initially showed considerable diversity, but the number of laboratories applying adequate diagnostic strategies increased during the study period. We found an average interlaboratory CV of 50% (range 12%-152%) for analytes in absolute concentrations. Result normalization by forming ratios to the upper reference limits did not reduce this variation. Sixty-five percent of reported results were within biological variation-based analytical quality specifications. Clinical interpretation of the obtained analytical results was accurate, and most laboratories established the correct diagnosis in all distributions. Based on a case-based EQA scheme, variations were apparent in analytical and diagnostic performance between European specialist porphyria laboratories. Our findings reinforce the use of EQA schemes as an essential tool to assess both analytical and diagnostic processes and thereby to improve patient care in rare diseases.
NASA Astrophysics Data System (ADS)
Rabah, Mostafa; Elmewafey, Mahmoud; Farahan, Magda H.
2016-06-01
A geodetic control network is the wire-frame or the skeleton on which continuous and consistent mapping, Geographic Information Systems (GIS), and surveys are based. Traditionally, geodetic control points are established as permanent physical monuments placed in the ground and precisely marked, located, and documented. With the development of satellite surveying methods and their availability and high degree of accuracy, a geodetic control network could be established by using GNSS and referred to an international terrestrial reference frame used as a three-dimensional geocentric reference system for a country. Based on this concept, in 1992, the Egypt Survey Authority (ESA) established two networks, namely High Accuracy Reference Network (HARN) and the National Agricultural Cadastral Network (NACN). To transfer the International Terrestrial Reference Frame to the HARN, the HARN was connected with four IGS stations. The processing results were 1:10,000,000 (Order A) for HARN and 1:1,000,000 (Order B) for NACN relative network accuracy standard between stations defined in ITRF1994 Epoch1996. Since 1996, ESA did not perform any updating or maintaining works for these networks. To see how non-performing maintenance degrading the values of the HARN and NACN, the available HARN and NACN stations in the Nile Delta were observed. The Processing of the tested part was done by CSRS-PPP Service based on utilizing Precise Point Positioning "PPP" and Trimble Business Center "TBC". The study shows the feasibility of Precise Point Positioning in updating the absolute positioning of the HARN network and its role in updating the reference frame (ITRF). The study also confirmed the necessity of the absent role of datum maintenance of Egypt networks.
Building a Unified Information Network.
ERIC Educational Resources Information Center
Avram, Henriette D.
1988-01-01
Discusses cooperative efforts between research organizations and libraries to create a national information network. Topics discussed include the Linked System Project (LSP); technical processing versus reference and research functions; Open Systems Interconnection (OSI) Reference Model; the National Science Foundation Network (NSFNET); and…
ERIC Educational Resources Information Center
Conlon, Michael P.; Mullins, Paul
2011-01-01
The Computer Science Department at Slippery Rock University created a laboratory for its Computer Networks and System Administration and Security courses under relaxed financial constraints. This paper describes the department's experience designing and using this laboratory, including lessons learned and descriptions of some student projects…
Hematological reference values of healthy Malaysian population.
Roshan, T M; Rosline, H; Ahmed, S A; Rapiaah, M; Wan Zaidah, A; Khattak, M N
2009-10-01
Health and disease can only be distinguished by accurate and reliable reference values of a particular laboratory test. It is now a proven fact that there is considerable variation in hematology reference intervals depending on the demographic and preanalytical variables. There are evidences that values provided by manufacturers do not have appropriate application for all populations. Moreover, reference ranges provided by different laboratory manuals and books also do not solve this problem. We are presenting here normal reference ranges of Malaysian population. These values were determined by using Sysmex XE-2100 and ACL 9000 hematology and coagulation analyzers. Results from this study showed that there were considerable differences in the reference values from manufacturers, western population or laboratory manuals compared with those from the local population.
GHSI EMERGENCY RADIONUCLIDE BIOASSAY LABORATORY NETWORK: SUMMARY OF A RECENT EXERCISE.
Li, Chunsheng; Ansari, Armin; Bartizel, Christine; Battisti, Paolo; Franck, Didier; Gerstmann, Udo; Giardina, Isabella; Guichet, Claude; Hammond, Derek; Hartmann, Martina; Jones, Robert L; Kim, Eunjoo; Ko, Raymond; Morhard, Ryan; Quayle, Deborah; Sadi, Baki; Saunders, David; Paquet, Francois
2016-11-01
The Global Health Security Initiative (GHSI) established a laboratory network within the GHSI community to develop their collective surge capacity for radionuclide bioassay in response to a radiological or nuclear emergency. A recent exercise was conducted to test the participating laboratories for their capabilities in screening and in vitro assay of biological samples, performing internal dose assessment and providing advice on medical intervention, if necessary, using a urine sample spiked with a single radionuclide, 241 Am. The laboratories were required to submit their reports according to the exercise schedule and using pre-formatted templates. Generally, the participating laboratories were found to be capable with respect to rapidly screening samples for radionuclide contamination, measuring the radionuclide in the samples, assessing the intake and radiation dose, and providing advice on medical intervention. However, gaps in bioassay measurement and dose assessment have been identified. The network may take steps to ensure that procedures and practices within this network be harmonised and a follow-up exercise be organised on a larger scale, with potential participation of laboratories from the networks coordinated by the International Atomic Energy Agency and the World Health Organization. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Environmental Response Laboratory Network (ERLN) Overview
The Environmental Response Laboratory Network provides Federal, State, and local decision-makers with reliable, high quality analytical data used to identify chemical, biological, and radiological contaminants collected in support of response and cleanup.
Old boys' network in general practitioners' referral behavior?
Hackl, Franz; Hummer, Michael; Pruckner, Gerald J
2015-09-01
We analyzed the impact of social networks on general practitioners' (GPs) referral behavior based on administrative panel data from 2,684,273 referrals to specialists made between 1998 and 2007. For the definition of social networks, we used information on the doctors' place and time of study and their hospital work history. We found that GPs referred more patients to specialists within their personal networks and that patients referred within a social network had fewer follow-up consultations and less inpatient days thereafter. The effects on patient outcomes (e.g. waiting periods, days in hospital) of referrals within personal networks and affinity-based networks differed. Specifically, whereas empirical evidence showed a concentration on high-quality specialists for referrals within the personal network, suggesting that referrals within personal networks overcome information asymmetry with respect to specialists' abilities, the empirical evidence for affinity-based networks was different and less clear. Same-gender networks tended to refer patients to low-quality specialists. Copyright © 2015 Elsevier B.V. All rights reserved.
Bartlett, John M S; Campbell, Fiona M; Ibrahim, Merdol; Thomas, Jeremy; Wencyk, Pete; Ellis, Ian; Kay, Elaine; Connolly, Yvonne; O'Grady, Anthony; Barnett, Sarah; Starczynski, Jane; Cunningham, Paul; Miller, Keith
2010-02-01
To assess a new HER2 fluorescence in situ hybridization (FISH) test and report on multicentre intrasite and intersite variation. HER2 results were scored from 45 breast cancers in eight laboratories using the Kreatech Poseidon HER2 FISH probe (Kreatech Diagnostics, Amsterdam, the Netherlands). Overall, 80.9% of cores were successfully analysed. Mean intrasite variation for HER2 ratio assessment was low (4.74%). Intersite variation in ratio was in line with previous reports (11.9+/-0.8%) for both reference and non-reference laboratories; only one laboratory displayed significantly higher intersite variation (P=0.009) than the remaining seven laboratories. The overall incidence of misclassification of cores was <1.3%, demonstrating an excellent level of concordance (>98.7%) across all eight laboratories, irrespective of whether they were 'reference' or 'routine diagnostic' laboratories. The Kreatech Poseidon HER2 FISH test is robust and reproducible. Highly quantitatively reproducible FISH results were obtained from eight 'diagnostic' and 'reference' laboratories; however, continued quality assessments are essential to good performance.
NASA Astrophysics Data System (ADS)
Sousa, J. T.; Pinto, J.; Martins, R.; Costa, M.; Ferreira, F.; Gomes, R.
2014-12-01
The problem of developing mobile oceanographic and atmospheric observation networks (MOAO) with coordinated air and ocean vehicles is discussed in the framework of the communications and control software tool chain developed at Underwater Systems and Technologies Laboratory (LSTS) from Porto University. This is done with reference to field experiments to illustrate key capabilities and to assess future MOAO operations. First, the motivation for building MOAO by "composition" of air and ocean vehicles, communication networks, and planning and execution control frameworks is discussed - in networked vehicle systems information and commands are exchanged among multiple vehicles and operators, and the roles, relative positions, and dependencies of these vehicles and operators change during operations. Second, the planning and execution control framework developed at LSTS for multi-vehicle systems is discussed with reference to key concepts such as autonomy, mixed-initiative interactions, and layered organization. Third, the LSTS tool software tool chain is presented to show how to develop MOAO by composition. The tool chain comprises the Neptus command and control framework for mixed initiative interactions, the underlying IMC messaging protocol, and the DUNE on-board software. Fourth, selected LSTS operational deployments illustrate MOAO capability building. In 2012 we demonstrated the use of UAS to "ferry" data from UUVs located beyond line of sight (BLOS). In 2013 we demonstrated coordinated observations of coastal fronts with small UAS and UUVs, "bent" BLOS through the use of UAS as communication relays, and UAS tracking of juvenile hammer-head sharks. In 2014 we demonstrated UUV adaptive sampling with the closed loop controller of the UUV residing on a UAS; this was done with the help of a Wave Glider ASV with a communications gateway. The results from these experiments provide a background for assessing potential future UAS operations in a compositional MOAO.
Habeck, C; Gazes, Y; Razlighi, Q; Steffener, J; Brickman, A; Barulli, D; Salthouse, T; Stern, Y
2016-01-15
Analyses of large test batteries administered to individuals ranging from young to old have consistently yielded a set of latent variables representing reference abilities (RAs) that capture the majority of the variance in age-related cognitive change: Episodic Memory, Fluid Reasoning, Perceptual Processing Speed, and Vocabulary. In a previous paper (Stern et al., 2014), we introduced the Reference Ability Neural Network Study, which administers 12 cognitive neuroimaging tasks (3 for each RA) to healthy adults age 20-80 in order to derive unique neural networks underlying these 4 RAs and investigate how these networks may be affected by aging. We used a multivariate approach, linear indicator regression, to derive a unique covariance pattern or Reference Ability Neural Network (RANN) for each of the 4 RAs. The RANNs were derived from the neural task data of 64 younger adults of age 30 and below. We then prospectively applied the RANNs to fMRI data from the remaining sample of 227 adults of age 31 and above in order to classify each subject-task map into one of the 4 possible reference domains. Overall classification accuracy across subjects in the sample age 31 and above was 0.80±0.18. Classification accuracy by RA domain was also good, but variable; memory: 0.72±0.32; reasoning: 0.75±0.35; speed: 0.79±0.31; vocabulary: 0.94±0.16. Classification accuracy was not associated with cross-sectional age, suggesting that these networks, and their specificity to the respective reference domain, might remain intact throughout the age range. Higher mean brain volume was correlated with increased overall classification accuracy; better overall performance on the tasks in the scanner was also associated with classification accuracy. For the RANN network scores, we observed for each RANN that a higher score was associated with a higher corresponding classification accuracy for that reference ability. Despite the absence of behavioral performance information in the derivation of these networks, we also observed some brain-behavioral correlations, notably for the fluid-reasoning network whose network score correlated with performance on the memory and fluid-reasoning tasks. While age did not influence the expression of this RANN, the slope of the association between network score and fluid-reasoning performance was negatively associated with higher ages. These results provide support for the hypothesis that a set of specific, age-invariant neural networks underlies these four RAs, and that these networks maintain their cognitive specificity and level of intensity across age. Activation common to all 12 tasks was identified as another activation pattern resulting from a mean-contrast Partial-Least-Squares technique. This common pattern did show associations with age and some subject demographics for some of the reference domains, lending support to the overall conclusion that aspects of neural processing that are specific to any cognitive reference ability stay constant across age, while aspects that are common to all reference abilities differ across age. Copyright © 2015 Elsevier Inc. All rights reserved.
Blood lipid measurements. Variations and practical utility.
Cooper, G R; Myers, G L; Smith, S J; Schlant, R C
1992-03-25
To describe the magnitude and impact of the major biological and analytical sources of variation in serum lipid and lipoprotein levels on risk of coronary heart disease; to present a way to qualitatively estimate the total intraindividual variation; and to demonstrate how to determine the number of specimens required to estimate, with 95% confidence, the "true" underlying total cholesterol value in the serum of a patient. Representative references on each source of variation were selected from more than 300 reviewed publications, most published within the past 5 years, to document current findings and concepts. Most articles reviewed were in English. Studies on biological sources of variation were selected using the following criteria: representative of published findings, clear statement of either significant or insignificant results, and acquisition of clinical and laboratory data under standardized conditions. Representative results for special populations such as women and children are reported when results differ from those of adult men. References were selected based on acceptable experimental design and use of standardized laboratory lipid measurements. The lipid levels considered representative for a selected source of variation arose from quantitative measurements by a suitably standardized laboratory. Statistical analysis of data was examined to assure reliability. The proposed method of estimating the biological coefficient of variation must be considered to give qualitative results, because only two or three serial specimens are collected in most cases for the estimation. Concern has arisen about the magnitude, impact, and interpretation of preanalytical as well as analytical sources of variation on reported results of lipid measurements of an individual. Preanalytical sources of variation from behavioral, clinical, and sampling sources constitute about 60% of the total variation in a reported lipid measurement of an individual. A technique is presented to allow physicians to qualitatively estimate the intraindividual biological variation of a patient from the results of two or more specimens reported from a standardized laboratory and to determine whether additional specimens are needed to meet the National Cholesterol Education Program recommendation that the intraindividual serum total cholesterol coefficient of variation not exceed 5.0. A National Reference Method Network has been established to help solve analytical problems.
Pfaller, M A; Hazen, K C; Messer, S A; Boyken, L; Tendolkar, S; Hollis, R J; Diekema, D J
2004-08-01
The accuracy of antifungal susceptibility tests is important for accurate resistance surveillance and for the clinical management of patients with serious infections. Our main objective was to compare the results of fluconazole disk diffusion testing of Candida spp. performed by ARTEMIS participating centers with disk diffusion and MIC results obtained by the central reference laboratory. A total of 2,949 isolates of Candida spp. were tested by NCCLS disk diffusion and reference broth microdilution methods in the central reference laboratory. These results were compared to the results of disk diffusion testing performed in the 54 participating centers. All tests were performed and interpreted following NCCLS recommendations. Overall categorical agreement between participant disk diffusion test results and reference laboratory MIC results was 87.4%, with 0.2% very major errors (VME) and 3.3% major errors (ME). The categorical agreement between the disk diffusion test results obtained in the reference laboratory with the MIC test results was similar: 92.8%. Likewise, good agreement was observed between participant disk diffusion test results and reference laboratory disk diffusion test results: 90.4%, 0.4% VME, and 3.4% ME. The disk diffusion test was especially reliable in detecting those isolates of Candida spp. that were characterized as resistant by reference MIC testing. External quality assurance data obtained by surveillance programs such as the ARTEMIS Global Antifungal Surveillance Program ensure the generation of useful surveillance data and result in the continued improvement of antifungal susceptibility testing practices.
Roles of laboratories and laboratory systems in effective tuberculosis programmes
van Deun, Armand; Kam, Kai Man; Narayanan, PR; Aziz, Mohamed Abdul
2007-01-01
Abstract Laboratories and laboratory networks are a fundamental component of tuberculosis (TB) control, providing testing for diagnosis, surveillance and treatment monitoring at every level of the health-care system. New initiatives and resources to strengthen laboratory capacity and implement rapid and new diagnostic tests for TB will require recognition that laboratories are systems that require quality standards, appropriate human resources, and attention to safety in addition to supplies and equipment. To prepare the laboratory networks for new diagnostics and expanded capacity, we need to focus efforts on strengthening quality management systems (QMS) through additional resources for external quality assessment programmes for microscopy, culture, drug susceptibility testing (DST) and molecular diagnostics. QMS should also promote development of accreditation programmes to ensure adherence to standards to improve both the quality and credibility of the laboratory system within TB programmes. Corresponding attention must be given to addressing human resources at every level of the laboratory, with special consideration being given to new programmes for laboratory management and leadership skills. Strengthening laboratory networks will also involve setting up partnerships between TB programmes and those seeking to control other diseases in order to pool resources and to promote advocacy for quality standards, to develop strategies to integrate laboratories’ functions and to extend control programme activities to the private sector. Improving the laboratory system will assure that increased resources, in the form of supplies, equipment and facilities, will be invested in networks that are capable of providing effective testing to meet the goals of the Global Plan to Stop TB. PMID:17639219
Reference values of thirty-one frequently used laboratory markers for 75-year-old males and females
Ryden, Ingvar; Lind, Lars
2012-01-01
Background We have previously reported reference values for common clinical chemistry tests in healthy 70-year-old males and females. We have now repeated this study 5 years later to establish reference values also at the age of 75. It is important to have adequate reference values for elderly patients as biological markers may change over time, and adequate reference values are essential for correct clinical decisions. Methods We have investigated 31 frequently used laboratory markers in 75-year-old males (n = 354) and females (n = 373) without diabetes. The 2.5 and 97.5 percentiles for these markers were calculated according to the recommendations of the International Federation of Clinical Chemistry. Results Reference values are reported for 75-year-old males and females for 31 frequently used laboratory markers. Conclusion There were minor differences between reference intervals calculated with and without individuals with cardiovascular diseases. Several of the reference intervals differed from Scandinavian reference intervals based on younger individuals (Nordic Reference Interval Project). PMID:22300333
Earth Regime Network Evolution Study (ERNESt)
NASA Technical Reports Server (NTRS)
Menrad, Bob
2016-01-01
Speaker and Presenter at the Lincoln Laboratory Communications Workshop on April 5, 2016 at the Massachusetts Institute of Technology Lincoln Laboratory in Lexington, MA. A visual presentation titled Earth Regimes Network Evolution Study (ERNESt).
Environmental Response Laboratory Network
The ERLN as a national network of laboratories that can be ramped up as needed to support large scale environmental responses. It integrates capabilities of existing public and private sector labs, providing consistent capacity and quality data.
2012-12-14
Quality surveillance is critical to the control and elimination of vaccine-preventable diseases (VPDs). A key strategy for enhancing VPD surveillance, outlined in the World Health Organization (WHO) Global Framework for Immunization Monitoring and Surveillance (GFIMS), is to expand and link existing VPD surveillance systems (particularly those developed for polio eradication and measles elimination) to include other priority VPDs. Since the launch of the Global Polio Eradication Initiative in 1988, the incidence of polio has decrease by 99% worldwide. A cornerstone of this success is a sensitive surveillance system based on the rapid and timely reporting of all acute flaccid paralysis (AFP) cases in children aged <15 years, with confirmatory diagnostic testing performed by laboratories that are part of a global network. As countries achieve polio-free status, many have expanded syndromic surveillance to include persons with rash and fever, and have built measles diagnostic capacity in existing polio reference laboratories. Acute meningitis/encephalitis syndrome (AMES) and acute encephalitis syndrome (AES) are candidates for expanded surveillance because they are most often caused by VPDs of public health importance for which confirmatory laboratory tests exist. Vaccine-preventable cases of encephalitis include approximately 68,000 Japanese encephalitis (JE) cases, resulting in 13,000-20,000 deaths each year in Asia. Moreover, although bacterial meningitis incidence in Asia is not as well-documented, pneumococcal and meningococcal meningitis outbreaks have been reported in Bangladesh and China, and the incidence of Haemophilus influenzae type b (Hib) meningitis in children aged <5 years in India has been estimated to be 7.1 per 100,000 population, similar to that in European countries before the introduction of vaccine. This report describes a prototype for expanding existing polio and measles surveillance networks in Bangladesh, China, and India to include surveillance for viral and bacterial vaccine-preventable causes of AMES and AES and presents data from 2006-2008.
Enhancing Chemical Inventory Management in Laboratory through a Mobile-Based QR Code Tag
NASA Astrophysics Data System (ADS)
Shukran, M. A. M.; Ishak, M. S.; Abdullah, M. N.
2017-08-01
The demand for a greater inventory management system which can provide a lot of useful information from a single scan has made laboratory inventory management using barcode technology more difficult. Since the barcode technology lacks the ability to overcome the problem and is not capable of providing information needed to manage the chemicals in the laboratory, thus employing a QR code technology is the best solution. In this research, the main idea is to develop a standalone application running with its own database that is periodically synchronized with the inventory software hosted by the computer and connected to a specialized network as well. The first process required to establish this centralized system is to determine all inventory available in the chemical laboratory by referring to the documented data in order to develop the database. Several customization and enhancement were made to the open source QR code technology to ensure the developed application is dedicated for its main purposes. As the end of the research, it was proven that the system is able to track the position of all inventory and showing real time information about the scanned chemical labels. This paper intends to give an overview about the QR tag inventory system that was developed and its implementation at the National Defence University of Malaysia’s (NDUM) chemical laboratory.
Woodworth, M.T.; Connor, B.F.
2001-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-165 (trace constituents), M-158 (major constituents), N-69 (nutrient constituents), N-70 (nutrient constituents), P-36 (low ionic-strength constituents), and Hg-32 (mercury) -- that were distributed in April 2001 to laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data received from 73 laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Woodworth, M.T.; Conner, B.F.
2002-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T- 169 (trace constituents), M- 162 (major constituents), N-73 (nutrient constituents), N-74 (nutrient constituents), P-38 (low ionic-strength constituents), and Hg-34 (mercury) -- that were distributed in March 2002 to laboratories enrolled in the U.S. Geological Survey sponsored intedaboratory testing program. Analytical data received from 93 laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Woodworth, Mark T.; Connor, Brooke F.
2003-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-171 (trace constituents), M-164 (major constituents), N-75 (nutrient constituents), N-76 (nutrient constituents), P-39 (low ionic-strength constituents), and Hg-35 (mercury) -- that were distributed in September 2002 to laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data received from 102 laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Woodworth, Mark T.; Connor, Brooke F.
2002-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-167 (trace constituents), M-160 (major constituents), N-71 (nutrient constituents), N-72 (nutrient constituents), P-37 (low ionic-strength constituents), and Hg-33 (mercury) -- that were distributed in September 2001 to laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data received from 98 laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Farrar, Jerry W.; Copen, Ashley M.
2000-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-161 (trace constituents), M-154 (major constituents), N-65 (nutrient constituents), N-66 nutrient constituents), P-34 (low ionic strength constituents), and Hg-30 (mercury) -- that were distributed in March 2000 to 144 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 132 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Farrar, T.W.
2000-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-159 (trace constituents), M-152 (major constituents), N-63 (nutrient constituents), N-64 (nutrient constituents), P-33 (low ionic strength constituents), and Hg-29 (mercury) -- that were distributed in October 1999 to 149 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 131 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Woodworth, Mark T.; Connor, Brooke F.
2003-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-173 (trace constituents), M-166 (major constituents), N-77 (nutrient constituents), N-78 (nutrient constituents), P-40 (low ionic-strength constituents), and Hg-36 (mercury) -- that were distributed in March 2003 to laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data received from 110 laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Connor, B.F.; Currier, J.P.; Woodworth, M.T.
2001-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-163 (trace constituents), M-156 (major constituents), N-67 (nutrient constituents), N-68 (nutrient constituents), P-35 (low ionic strength constituents), and Hg-31 (mercury) -- that were distributed in October 2000 to 126 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 122 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Karon, Brad S; Wickremasinghe, Andrea C; Lo, Stanley F; Saenger, Amy K; Cook, Walter J
2010-08-01
To determine the relationship between BiliChek TcB (Respironics, Marietta GA) and Doumas reference serum or plasma total bilirubin (TSB). Pooled samples with values assigned by the Doumas reference method were used to establish the relationship between a local laboratory and reference Doumas TSB. We then established the relationship between TcB and TSB in the 3 months before and after reassignment of calibrator setpoints undertaken to match the local laboratory to Doumas reference bilirubin values. Before calibrator setpoint reassignment TSB as measured in our laboratory overestimated Doumas reference bilirubin. After calibrator adjustment laboratory TSB was within 1.7-6.8 micromol/L (0.1-0.4 mg/dL) of Doumas reference values. Mean bias between BiliChek TcB and TSB was 42.8+/-22.2 micromol/L (2.5+/-1.3mg/dL) (n=94) before and 49.6+/-22.2 micromol/L (2.9+/-1.3mg/dL) (n=115) after calibration adjustment. BiliChek TcB significantly overestimates TSB as measured by the Doumas reference method. 2010 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Naito, H K
1989-03-01
We have approached a dawn of a new era in detection, evaluation, treatment, and monitoring of individuals with elevated blood cholesterol levels who are at increased risk for CHD. The NHLBI's National Cholesterol Education Program will be the major force underlying this national awareness program, which is dependent on the clinical laboratories providing reliable data. Precision or reproducibility of results is not a problem for most of the laboratories, but accuracy is a major concern. Both the manufacturers and laboratorians need to standardize the measurement for cholesterol so that the accuracy base is traceable to the NCCLS NRS/CHOL. The manufacturers need to adopt a uniform policy that will ensure that the values assigned to calibration, quality control, and quality assurance or survey materials are accurate and traceable to the NCCLS/CHOL. Since, at present, there are some limitations of these materials caused by matrix effects, laboratories are encouraged to use the CDC-NHLBI National Reference Laboratory Network to evaluate and monitor their ability to measure patient blood cholesterol levels accurately. Major areas of analytical problems are identified and general, as well as specific, recommendations are provided to help ensure reliable measurement of cholesterol in patient specimens.
EMQN/CMGS best practice guidelines for the molecular genetic testing of Huntington disease.
Losekoot, Monique; van Belzen, Martine J; Seneca, Sara; Bauer, Peter; Stenhouse, Susan A R; Barton, David E
2013-05-01
Huntington disease (HD) is caused by the expansion of an unstable polymorphic trinucleotide (CAG)n repeat in exon 1 of the HTT gene, which translates into an extended polyglutamine tract in the protein. Laboratory diagnosis of HD involves estimation of the number of CAG repeats. Molecular genetic testing for HD is offered in a wide range of laboratories both within and outside the European community. In order to measure the quality and raise the standard of molecular genetic testing in these laboratories, the European Molecular Genetics Quality Network has organized a yearly external quality assessment (EQA) scheme for molecular genetic testing of HD for over 10 years. EQA compares a laboratory's output with a fixed standard both for genotyping and reporting of the results to the referring physicians. In general, the standard of genotyping is very high but the clarity of interpretation and reporting of the test result varies more widely. This emphasizes the need for best practice guidelines for this disorder. We have therefore developed these best practice guidelines for genetic testing for HD to assist in testing and reporting of results. The analytical methods and the potential pitfalls of molecular genetic testing are highlighted and the implications of the different test outcomes for the consultand and his or her family members are discussed.
Safety Precautions and Operating Procedures in an (A)BSL-4 Laboratory: 3. Aerobiology.
Bohannon, J Kyle; Janosko, Krisztina; Holbrook, Michael R; Barr, Jason; Pusl, Daniela; Bollinger, Laura; Coe, Linda; Hensley, Lisa E; Jahrling, Peter B; Wada, Jiro; Kuhn, Jens H; Lackemeyer, Matthew G
2016-10-03
Aerosol or inhalational studies of high-consequence pathogens have recently been increasing in number due to the perceived threat of intentional aerosol releases or unexpected natural aerosol transmission. Specific laboratories designed to perform these experiments require tremendous engineering controls to provide a safe and secure working environment and constant systems maintenance to sustain functionality. Class III biosafety cabinets, also referred to as gloveboxes, are gas-tight enclosures with non-opening windows. These cabinets are maintained under negative pressure by double high-efficiency-particulate-air (HEPA)-filtered exhaust systems and are the ideal primary containment for housing aerosolization equipment. A well planned workflow between staff members within high containment from, for instance, an animal biosafety level-4 (ABSL-4) suit laboratory to the ABSL-4 cabinet laboratory is a crucial component for successful experimentation. For smooth study execution, establishing a communication network, moving equipment and subjects, and setting up and placing equipment, requires staff members to meticulously plan procedures prior to study initiation. Here, we provide an overview and a visual representation of how aerobiology research is conducted at the National Institutes of Health, National Institute of Allergy and Infectious Diseases Integrated Research Facility at Fort Detrick, Maryland, USA, within an ABSL-4 environment.
Packet Traffic Dynamics Near Onset of Congestion in Data Communication Network Model
NASA Astrophysics Data System (ADS)
Lawniczak, A. T.; Tang, X.
2006-05-01
The dominant technology of data communication networks is the Packet Switching Network (PSN). It is a complex technology organized as various hierarchical layers according to the International Standard Organization (ISO) Open Systems Interconnect (OSI) Reference Model. The Network Layer of the ISO OSI Reference Model is responsible for delivering packets from their sources to their destinations and for dealing with congestion if it arises in a network. Thus, we focus on this layer and present an abstraction of the Network Layer of the ISO OSI Reference Model. Using this abstraction we investigate how onset of traffic congestion is affected for various routing algorithms by changes in network connection topology. We study how aggregate measures of network performance depend on network connection topology and routing. We explore packets traffic spatio-temporal dynamics near the phase transition point from free flow to congestion for various network connection topologies and routing algorithms. We consider static and adaptive routings. We present selected simulation results.
ERIC Educational Resources Information Center
Palmer, Jackie; Powell, Mary Jo
The Laboratory Network Program and the National Network of Eisenhower Mathematics and Science Regional Consortia, operating as the Curriculum Frameworks Task Force, jointly convened a group of educators involved in implementing state-level mathematics or science curriculum frameworks (CF). The Hilton Head (South Carolina) conference had a dual…
Combatting Global Infectious Diseases: A Network Effect of Specimen Referral Systems.
Fonjungo, Peter N; Alemnji, George A; Kebede, Yenew; Opio, Alex; Mwangi, Christina; Spira, Thomas J; Beard, R Suzanne; Nkengasong, John N
2017-02-13
The recent Ebola virus outbreak in West Africa clearly demonstrated the critical role of laboratory systems and networks in responding to epidemics. Because of the huge challenges in establishing functional laboratories at all tiers of health systems in developing countries, strengthening specimen referral networks is critical. In this review article, we propose a platform strategy for developing specimen referral networks based on 2 models: centralized and decentralized laboratory specimen referral networks. These models have been shown to be effective in patient management in programs in resource-limited settings. Both models lead to reduced turnaround time and retain flexibility for integrating different specimen types. In Haiti, decentralized specimen referral systems resulted in a 182% increase in patients enrolling in human immunodeficiency virus treatment programs within 6 months. In Uganda, cost savings of up to 62% were observed with a centralized model. A platform strategy will create a network effect that will benefit multiple disease programs.
Optical fiber cable and wiring techniques for fiber to the home (FTTH)
NASA Astrophysics Data System (ADS)
Takai, Hirofumi; Yamauchi, Osamu
2009-08-01
NTT group's new medium-term management strategy calls for 20 million optical subscribers by 2010, and NTT Laboratories is pushing forward to meet this goal. Before that date, an efficient optical access network must be constructed, and afterwards, when the era of mass optical communications finally arrives, the facilities and equipment supporting the network will have to be effectively operated and maintained. At NTT Access Network Service Systems Laboratories, we are developing various technologies to correspond to the massive deployment of optical broadband services. We are also developing various new technologies for efficiently operating optical access network systems that will continue to expand in the future, and to supply our customers with good services. This paper provides an overview of the new optical access network system technologies that are being developed at NTT Access Network Service Systems Laboratories to address these issues.
NASA Astrophysics Data System (ADS)
Wang, Y.; Li, C. H.
2017-07-01
Researchers have recently realized that the natural fractures in shale reservoirs are often cemented or sealed with various minerals. However, the influence of cement characteristics of natural fracture on fracturing network propagation is still not well understood. In this work, laboratory-scaled experiments are proposed to prepare model blocks with discrete orthogonal fractures network with different strength of natural fracture, in order to reveal the influence of cemented natural fractures on the interactions between hydraulic fractures and natural fractures. A series of true triaxial hydraulic fracturing experiments were conducted to investigate the mechanism of hydraulic fracture initiation and propagation in model blocks with natural fractures of different cement strength. The results present different responses of interactions between hydraulic and natural fractures, which can be reflected on the pump pressure profiles and block failure morphology. For model blocks with fluctuated pump pressure curves, the communication degree of hydraulic and natural fractures is good, which is confirmed by a proposed new index of "P-SRV." The most significant finding is that too high and too low strength properties of cemented natural fracture are adverse to generate complex fracturing network. This work can help us better understand how cemented natural fractures affect the fracturing network propagation subsurface and give us reference to develop more accurate hydraulic fracturing models.
MadSciNet: The 24-hour exploding laboratory.
Page New! Help Improve The Madsci Network Help Support MadSci MAD Head MAD egg Welcome to the laboratory that never sleeps! MadSci Network represents a collective cranium of scientists providing answers Sunday May 27, 2018. Lynn MadSci Network is a non-profit organization operating in partnership with Third
Environmental Response Laboratory Network (ERLN) Public Labs Fact Sheet
Outlines goals for participation in the Environmental Response Laboratory Network, and FAQs. They play an integral role in a coordinated and operational system of labs capable of efficiently and effectively responding to incidents.
A report on FY06 IPv6 deployment activities and issues at Sandia National Laboratories.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tolendino, Lawrence F.; Eldridge, John M.; Hu, Tan Chang
2006-06-01
Internet Protocol version 4 (IPv4) has been a mainstay of the both the Internet and corporate networks for delivering network packets to the desired destination. However, rapid proliferation of network appliances, evolution of corporate networks, and the expanding Internet has begun to stress the limitations of the protocol. Internet Protocol version 6 (IPv6) is the replacement protocol that overcomes the constraints of IPv4. IPv6 deployment in government network backbones has been mandated to occur by 2008. This paper explores the readiness of the Sandia National Laboratories' network backbone to support IPv6, the issues that must be addressed before a deploymentmore » begins, and recommends the next steps to take to comply with government mandates. The paper describes a joint, work effort of the Sandia National Laboratories ASC WAN project team and members of the System Analysis & Trouble Resolution and Network System Design & Implementation Departments.« less
Rowland, Zarah; Wenzel, Mario; Kubiak, Thomas
2016-12-01
Self-control is an important ability in everyday life, showing associations with health-related outcomes. The aim of the Self-control and Mindfulness within Ambulatorily assessed network Systems across Health-related domains (SMASH) study is twofold: first, the effectiveness of a computer-based mindfulness training will be evaluated in a randomized controlled trial. Second, the SMASH study implements a novel network approach in order to investigate complex temporal interdependencies of self-control networks across several domains. The SMASH study is a two-armed, 6-week, non-blinded randomized controlled trial that combines seven weekly laboratory meetings and 40 days of electronic diary assessments with six prompts per day in a healthy undergraduate student population at the Johannes Gutenberg University Mainz, Germany. Participants will be randomly assigned to (1) receive a computer-based mindfulness intervention or (2) to a wait-list control condition. Primary outcomes are self-reported momentary mindfulness and self-control assessed via electronic diaries. Secondary outcomes are habitual mindfulness and habitual self-control. Further measures include self-reported behaviors in specific self-control domains: emotion regulation, alcohol consumption and eating behaviors. The effects of mindfulness training on primary and secondary outcomes are explored using three-level mixed models. Furthermore, networks will be computed with vector autoregressive mixed models to investigate the dynamics at participant and group level. This study was approved by the local ethics committee (reference code 2015_JGU_psychEK_011) and follows the standards laid down in the Declaration of Helsinki (2013). This randomized controlled trial combines an intensive Ambulatory Assessment of 40 consecutive days and seven laboratory meetings. By implementing a novel network approach, underlying processes of self-control within different health domains will be identified. These results will deepen the understanding of self-control performance and will guide to just-in-time individual interventions for several health-related behaviors. ClinicalTrials.gov, NCT02647801 . Registered on 15 December 2015 (registered retrospectively). .
Multicentre evaluation of the Premier Hb9210 HbA1c analyser
John, W. Garry; Little, Randie; Sacks, David B.; Weykamp, Cas; Lenters-Westra, Erna; Hornsby, Theresa; Zhao, Zhen; Siebelder, Carla; Tennill, Alethea; English, Emma
2017-01-01
Background The accurate and precise quantification of HbA1c is essential for the diagnosis and routine monitoring of patients with diabetes. We report an evaluation of the Trinity Biotech Premier Hb9210 analyser (Bray, Ireland/Kansas City, US), a boronate affinity chromatography-based high performance liquid chromatography (HPLC) system for the measurement of glycated haemoglobin. Methods We evaluated the analytical performance of the Hb9210 as part of a multicentre evaluation. The effect of haemoglobin variants, other potential interferences and the performance in comparison to both the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) and National Glycohemoglobin Standardization Program (NGSP) reference systems, was assessed. Most of the centres participating also act as reference laboratories for both the IFCC standardisation network for HbA1c and the NGSP. Results The combined data from all centres showed total CVs of 2.71%, 2.32% and 2.14% at low medium and high values respectively for mmol/mol (SI units) and 1.62%, 1.59% and 1.68% for % (NGSP units), which are well below the recommended upper limits of 3% CV for SI (IFCC) units and 2% CV for % (NGSP). The analyser showed a good correlation to HbA1c methods currently used in clinical practice and the IFCC reference method procedure. Haemoglobin variants AC, AS, AE and AD do not affect the measurement of HbA1c. Overall the Hb9210 performs well across the whole analytical range. Conclusions The Hb9210 performs well and is suitable for clinical application in the analysis of HbA1c. PMID:25274956
A report on IPv6 deployment activities and issues at Sandia National Laboratories:FY2007.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tolendino, Lawrence F.; Eldridge, John M.; Hu, Tan Chang
2007-06-01
Internet Protocol version 4 (IPv4) has been a mainstay of the both the Internet and corporate networks for delivering network packets to the desired destination. However, rapid proliferation of network appliances, evolution of corporate networks, and the expanding Internet has begun to stress the limitations of the protocol. Internet Protocol version 6 (IPv6) is the replacement protocol that overcomes the constraints of IPv4. As the emerging Internet network protocol, SNL needs to prepare for its eventual deployment in international, national, customer, and local networks. Additionally, the United States Office of Management and Budget has mandated that IPv6 deployment in governmentmore » network backbones occurs by 2008. This paper explores the readiness of the Sandia National Laboratories network backbone to support IPv6, the issues that must be addressed before a deployment begins, and recommends the next steps to take to comply with government mandates. The paper describes a joint work effort of the Sandia National Laboratories ASC WAN project team and members of the System Analysis & Trouble Resolution, the Communication & Network Systems, and Network System Design & Implementation Departments.« less
Report #09-P-0053, December 9, 2008. Vulnerability testing of EPA’s Radiation and Indoor Environments National Laboratory (R&IEN) network identified Internet Protocol addresses with medium-risk vulnerabilities.
fMRI evidence for strategic decision-making during resolution of pronoun reference
McMillan, Corey T.; Clark, Robin; Gunawardena, Delani; Ryant, Neville; Grossman, Murray
2012-01-01
Pronouns are extraordinarily common in daily language yet little is known about the neural mechanisms that support decisions about pronoun reference. We propose a large-scale neural network for resolving pronoun reference that consists of two components. First, a core language network in peri-Sylvian cortex supports syntactic and semantic resources for interpreting pronoun meaning in sentences. Second, a frontal-parietal network that supports strategic decision-making is recruited to support probabilistic and risk-related components of resolving a pronoun’s referent. In an fMRI study of healthy young adults, we observed activation of left inferior frontal and superior temporal cortex, consistent with a language network. We also observed activation of brain regions not associated with traditional language areas. By manipulating the context of the pronoun, we were able to demonstrate recruitment of dorsolateral prefrontal cortex during probabilistic evaluation of a pronoun’s reference, and orbital frontal activation when a pronoun must adopt a risky referent. Together, these findings are consistent with a two-component model for resolving a pronoun’s reference that includes neuroanatomic regions supporting core linguistic and decision-making mechanisms. PMID:22245014
Risch, Martin; Nydegger, Urs; Risch, Lorenz
2017-01-01
In clinical practice, laboratory results are often important for making diagnostic, therapeutic, and prognostic decisions. Interpreting individual results relies on accurate reference intervals and decision limits. Despite the considerable amount of resources in clinical medicine spent on elderly patients, accurate reference intervals for the elderly are rarely available. The SENIORLAB study set out to determine reference intervals in the elderly by investigating a large variety of laboratory parameters in clinical chemistry, hematology, and immunology. The SENIORLAB study is an observational, prospective cohort study. Subjectively healthy residents of Switzerland aged 60 years and older were included for baseline examination (n = 1467), where anthropometric measurements were taken, medical history was reviewed, and a fasting blood sample was drawn under optimal preanalytical conditions. More than 110 laboratory parameters were measured, and a biobank was set up. The study participants are followed up every 3 to 5 years for quality of life, morbidity, and mortality. The primary aim is to evaluate different laboratory parameters at age-related reference intervals. The secondary aims of this study include the following: identify associations between different parameters, identify diagnostic characteristics to diagnose different circumstances, identify the prevalence of occult disease in subjectively healthy individuals, and identify the prognostic factors for the investigated outcomes, including mortality. To obtain better grounds to justify clinical decisions, specific reference intervals for laboratory parameters of the elderly are needed. Reference intervals are obtained from healthy individuals. A major obstacle when obtaining reference intervals in the elderly is the definition of health in seniors because individuals without any medical condition and any medication are rare in older adulthood. Reference intervals obtained from such individuals cannot be considered representative for seniors in a status of age-specific normal health. In addition to the established methods for determining reference intervals, this longitudinal study utilizes a unique approach, in that survival and long-term well-being are taken as indicators of health in seniors. This approach is expected to provide robust and representative reference intervals that are obtained from an adequate reference population and not a collective of highly selected individuals. The present study was registered under International Standard Randomized Controlled Trial Number registry: ISRCTN53778569.
External Quality Assessment Scheme for reference laboratories - review of 8 years' experience.
Kessler, Anja; Siekmann, Lothar; Weykamp, Cas; Geilenkeuser, Wolf Jochen; Dreazen, Orna; Middle, Jonathan; Schumann, Gerhard
2013-05-01
We describe an External Quality Assessment Scheme (EQAS) intended for reference (calibration) laboratories in laboratory medicine and supervised by the Scientific Division of the International Federation of Clinical Chemistry and Laboratory Medicine and the responsible Committee on Traceability in Laboratory Medicine. The official EQAS website, RELA (www.dgkl-rfb.de:81), is open to interested parties. Information on all requirements for participation and results of surveys are published annually. As an additional feature, the identity of every participant in relation to the respective results is disclosed. The results of various groups of measurands (metabolites and substrates, enzymes, electrolytes, glycated hemoglobins, proteins, hormones, thyroid hormones, therapeutic drugs) are discussed in detail. The RELA system supports reference measurement laboratories preparing for accreditation according to ISO 17025 and ISO 15195. Participation in a scheme such as RELA is one of the requirements for listing of the services of a calibration laboratory by the Joint Committee on Traceability in Laboratory Medicine.
Wetherbee, Gregory A.; Martin, RoseAnn
2016-07-05
The Mercury Deposition Network programs include the system blank program and an interlaboratory comparison program. System blank results indicated that maximum total mercury contamination concentrations in samples were less than the third percentile of all Mercury Deposition Network sample concentrations. The Mercury Analytical Laboratory produced chemical concentration results with low bias and variability compared with other domestic and international laboratories that support atmospheric-deposition monitoring.
ERIC Educational Resources Information Center
Lavender, Kenneth; Nicholson, Scott; Pomerantz, Jeffrey
2005-01-01
While a growing number of the digital reference services in libraries have become part of collaborative reference networks, other entities that serve similar information-seeking needs such as special collections and museums have not joined these networks, even though they are answering an increasing number of questions from off-site patrons via…
GPS Data Analysis for Earth Orientation at the Jet Propulsion Laboratory
NASA Technical Reports Server (NTRS)
Zumberge, J.; Webb, F.; Lindqwister, U.; Lichten, S.; Jefferson, D.; Ibanez-Meier, R.; Heflin, M.; Freedman, A.; Blewitt, G.
1994-01-01
Beginning June 1992 and continuing indefinitely as part of our contribution to FLINN (Fiducial Laboratories for an International Natural Science Network), DOSE (NASA's Dynamics of the Solid Earth Program), and the IGS (International GPS Geodynamics Service), analysts at the Jet Propulsion Laboratory (JPL) have routinely been reducing data from a globally-distributed network of Rogue Global Positioning System (GPS) receivers.
NASA Astrophysics Data System (ADS)
Bodeker, G. E.; Thorne, P.; Braathen, G.; De Maziere, M.; Thompson, A. M.; Kurylo, M. J., III
2016-12-01
There are a number of ground-based global observing networks that collectively aim to make key measurements of atmospheric state variables and atmospheric chemical composition. These networks include, but are not limited to:NDACC: Network for the Detection of Atmospheric Composition Change GUAN: GCOS Upper Air Network GRUAN: GCOS Reference Upper Air Network EARLINET: the European Aerosol Research Lidar Network GAW: Global Atmosphere Watch SHADOZ: Southern Hemisphere ADditional OZonesondes TCCON: Total Carbon Column Observing Network BSRN: Baseline Surface Radiation Network While each network brings unique capabilities to the global observing system, there are many instances where the activities and capabilities of the networks overlap. These commonalities across multiple networks can confound funding agencies when allocating scarce financial resources. Overlaps between networks may also result in some duplication of effort and a resultant sub-optimal use of funding resource for the global observing system. While some degree of overlap is useful for quality assurance, it is essential to identify the degree to which one network can take on a specific responsibility on behalf of all other networks to avoid unnecessary duplication, to identify where expertise in any one network may serve other networks, and to develop a long-term strategy for the evolution of these networks that clarifies to funding agencies where new investment is required. This presentation will briefly summarise the key characteristics of each network listed above, adopt a matrix approach to identify commonalities and, in particular, where there may be a danger of duplication of effort, and where gaps between the networks may be compromising the services that these networks are expected to collectively deliver to the global atmospheric and climate science research communities. The presentation will also examine where sharing of data and tools between networks may result in a more efficient delivery of records of essential climate variables to the global research community. There are aspects of underpinning research that are needed across all of these networks, such as laboratory spectroscopy, that often do not receive the attention they deserve. The presentation will also seek to identify where that underpinning research is lacking.
Yang, Qian; Lew, Hwee Yeong; Peh, Raymond Hock Huat; Metz, Michael Patrick; Loh, Tze Ping
2016-10-01
Reference intervals are the most commonly used decision support tool when interpreting quantitative laboratory results. They may require partitioning to better describe subpopulations that display significantly different reference values. Partitioning by age is particularly important for the paediatric population since there are marked physiological changes associated with growth and maturation. However, most partitioning methods are either technically complex or require prior knowledge of the underlying physiology/biological variation of the population. There is growing interest in the use of continuous centile curves, which provides seamless laboratory reference values as a child grows, as an alternative to rigidly described fixed reference intervals. However, the mathematical functions that describe these curves can be complex and may not be easily implemented in laboratory information systems. Hence, the use of fixed reference intervals is expected to continue for a foreseeable time. We developed a method that objectively proposes optimised age partitions and reference intervals for quantitative laboratory data (http://research.sph.nus.edu.sg/pp/ppResult.aspx), based on the sum of gradient that best describes the underlying distribution of the continuous centile curves. It is hoped that this method may improve the selection of age intervals for partitioning, which is receiving increasing attention in paediatric laboratory medicine. Copyright © 2016 Royal College of Pathologists of Australasia. Published by Elsevier B.V. All rights reserved.
Research on NGN network control technology
NASA Astrophysics Data System (ADS)
Li, WenYao; Zhou, Fang; Wu, JianXue; Li, ZhiGuang
2004-04-01
Nowadays NGN (Next Generation Network) is the hotspot for discussion and research in IT section. The NGN core technology is the network control technology. The key goal of NGN is to realize the network convergence and evolution. Referring to overlay network model core on Softswitch technology, circuit switch network and IP network convergence realized. Referring to the optical transmission network core on ASTN/ASON, service layer (i.e. IP layer) and optical transmission convergence realized. Together with the distributing feature of NGN network control technology, on NGN platform, overview of combining Softswitch and ASTN/ASON control technology, the solution whether IP should be the NGN core carrier platform attracts general attention, and this is also a QoS problem on NGN end to end. This solution produces the significant practical meaning on equipment development, network deployment, network design and optimization, especially on realizing present network smooth evolving to the NGN. This is why this paper puts forward the research topic on the NGN network control technology. This paper introduces basics on NGN network control technology, then proposes NGN network control reference model, at the same time describes a realizable network structure of NGN. Based on above, from the view of function realization, NGN network control technology is discussed and its work mechanism is analyzed.
A Study of Gaps in Network Knowledge Synthesis
2016-10-14
Lincoln Laboratory MASSACHUSETTS INSTITUTE OF TECHNOLOGY LEXINGTON, MASSACHUSETTS Technical Report 1195 A Study of Gaps in Network...unlimited. This report is the result of studies performed at Lincoln Laboratory, a federally funded research and development center operated...specifically authorized by the U.S. Government may violate any copyrights that exist in this work. A Study of Gaps in Network Knowledge Synthesis
Coplen, T.B.; Qi, H.
2009-01-01
New isotope laboratories can achieve the goal of reporting the same isotopic composition within analytical uncertainty for the same material analysed decades apart by (1) writing their own acceptance testing procedures and putting them into their mass spectrometric or laser-based isotope-ratio equipment procurement contract, (2) requiring a manufacturer to demonstrate acceptable performance using all sample ports provided with the instrumentation, (3) for each medium to be analysed, prepare two local reference materials substantially different in isotopic composition to encompass the range in isotopic composition expected in the laboratory and calibrated them with isotopic reference materials available from the International Atomic Energy Agency (IAEA) or the US National Institute of Standards and Technology (NIST), (4) using the optimum storage containers (for water samples, sealing in glass ampoules that are sterilised after sealing is satisfactory), (5) interspersing among sample unknowns local laboratory isotopic reference materials daily (internationally distributed isotopic reference materials can be ordered at three-year intervals, and can be used for elemental analyser analyses and other analyses that consume less than 1 mg of material) - this process applies to H, C, N, O, and S isotope ratios, (6) calculating isotopic compositions of unknowns by normalising isotopic data to that of local reference materials, which have been calibrated to internationally distributed isotopic reference materials, (7) reporting results on scales normalised to internationally distributed isotopic reference materials (where they are available) and providing to sample submitters the isotopic compositions of internationally distributed isotopic reference materials of the same substance had they been analysed with unknowns, (8) providing an audit trail in the laboratory for analytical results - this trail commonly will be in electronic format and might include a laboratory information management system, (9) making at regular intervals a complete backup of laboratory analytical data (both of samples logged into the laboratory and of mass spectrometric analyses), being sure to store one copy of this backup offsite, and (10) participating in interlaboratory comparison exercises sponsored by the IAEA and other agencies at regular intervals. ?? Taylor & Francis.
Shin, Junha; Lee, Insuk
2015-01-01
Phylogenetic profiling, a network inference method based on gene inheritance profiles, has been widely used to construct functional gene networks in microbes. However, its utility for network inference in higher eukaryotes has been limited. An improved algorithm with an in-depth understanding of pathway evolution may overcome this limitation. In this study, we investigated the effects of taxonomic structures on co-inheritance analysis using 2,144 reference species in four query species: Escherichia coli, Saccharomyces cerevisiae, Arabidopsis thaliana, and Homo sapiens. We observed three clusters of reference species based on a principal component analysis of the phylogenetic profiles, which correspond to the three domains of life—Archaea, Bacteria, and Eukaryota—suggesting that pathways inherit primarily within specific domains or lower-ranked taxonomic groups during speciation. Hence, the co-inheritance pattern within a taxonomic group may be eroded by confounding inheritance patterns from irrelevant taxonomic groups. We demonstrated that co-inheritance analysis within domains substantially improved network inference not only in microbe species but also in the higher eukaryotes, including humans. Although we observed two sub-domain clusters of reference species within Eukaryota, co-inheritance analysis within these sub-domain taxonomic groups only marginally improved network inference. Therefore, we conclude that co-inheritance analysis within domains is the optimal approach to network inference with the given reference species. The construction of a series of human gene networks with increasing sample sizes of the reference species for each domain revealed that the size of the high-accuracy networks increased as additional reference species genomes were included, suggesting that within-domain co-inheritance analysis will continue to expand human gene networks as genomes of additional species are sequenced. Taken together, we propose that co-inheritance analysis within the domains of life will greatly potentiate the use of the expected onslaught of sequenced genomes in the study of molecular pathways in higher eukaryotes. PMID:26394049
... Laboratory Testing Confirming Anthrax Through the Laboratory Response Network FAQs Information for Specific Groups Laboratory Professionals Collecting Specimens Recommended Specimens Worker Safety ...
Guo, Wei; Song, Binbin; Shen, Junfei; Wu, Jiong; Zhang, Chunyan; Wang, Beili; Pan, Baishen
2015-08-25
To establish an indirect reference interval based on the test results of alanine aminotransferase stored in a laboratory information system. All alanine aminotransferase results were included for outpatients and physical examinations that were stored in the laboratory information system of Zhongshan Hospital during 2014. The original data were transformed using a Box-Cox transformation to obtain an approximate normal distribution. Outliers were identified and omitted using the Chauvenet and Tukey methods. The indirect reference intervals were obtained by simultaneously applying nonparametric and Hoffmann methods. The reference change value was selected to determine the statistical significance of the observed differences between the calculated and published reference intervals. The indirect reference intervals for alanine aminotransferase of all groups were 12 to 41 U/L (male, outpatient), 12 to 48 U/L (male, physical examination), 9 to 32 U/L (female, outpatient), and 8 to 35 U/L (female, physical examination), respectively. The absolute differences when compared with the direct results were all smaller than the reference change value of alanine aminotransferase. The Box-Cox transformation combined with the Hoffmann and Tukey methods is a simple and reliable technique that should be promoted and used by clinical laboratories.
Construction of a pulse-coupled dipole network capable of fear-like and relief-like responses
NASA Astrophysics Data System (ADS)
Lungsi Sharma, B.
2016-07-01
The challenge for neuroscience as an interdisciplinary programme is the integration of ideas among the disciplines to achieve a common goal. This paper deals with the problem of deriving a pulse-coupled neural network that is capable of demonstrating behavioural responses (fear-like and relief-like). Current pulse-coupled neural networks are designed mostly for engineering applications, particularly image processing. The discovered neural network was constructed using the method of minimal anatomies approach. The behavioural response of a level-coded activity-based model was used as a reference. Although the spiking-based model and the activity-based model are of different scales, the use of model-reference principle means that the characteristics that is referenced is its functional properties. It is demonstrated that this strategy of dissection and systematic construction is effective in the functional design of pulse-coupled neural network system with nonlinear signalling. The differential equations for the elastic weights in the reference model are replicated in the pulse-coupled network geometrically. The network reflects a possible solution to the problem of punishment and avoidance. The network developed in this work is a new network topology for pulse-coupled neural networks. Therefore, the model-reference principle is a powerful tool in connecting neuroscience disciplines. The continuity of concepts and phenomena is further maintained by systematic construction using methods like the method of minimal anatomies.
NASA Astrophysics Data System (ADS)
Siejka, Zbigniew
2017-09-01
GNSS systems are currently the basic tools for determination of the highest precision station coordinates (e.g. basic control network stations or stations used in the networks for geodynamic studies) as well as for land, maritime and air navigation. All of these tasks are carried out using active, large scale, satellite geodetic networks which are complex, intelligent teleinformatic systems offering post processing services along with corrections delivered in real-time for kinematic measurements. Many countries in the world, also in Europe, have built their own multifunctional networks and enhance them with their own GNSS augmentation systems. Nowadays however, in the era of international integration, there is a necessity to consider collective actions in order to build a unified system, covering e.g. the whole Europe or at least some of its regions. Such actions have already been undertaken in many regions of the world. In Europe such an example is the development for EUPOS which consists of active national networks built in central eastern European countries. So far experience and research show, that the critical areas for connecting these networks are border areas, in which the positioning accuracy decreases (Krzeszowski and Bosy, 2011). This study attempts to evaluate the border area compatibility of Polish ASG-EUPOS (European Position Determination System) reference stations and Ukrainian GeoTerrace system reference stations in the context of their future incorporation into the EUPOS. The two networks analyzed in work feature similar hardware parameters. In the ASG-EUPOS reference stations network, during the analyzed period, 2 stations (WLDW and CHEL) used only one system (GPS), while, in the GeoTerrace network, all the stations were equipped with both GPS and GLONASS receivers. The ASG EUPOS reference station network (95.6%) has its average completeness greater by about 6% when compared to the GeoTerrace network (89.8%).
NASA Astrophysics Data System (ADS)
Kumar, Anil; Kumar, Harish; Mandal, Goutam; Das, M. B.; Sharma, D. C.
The present paper discusses the establishment of traceability of reference grade hydrometers at National Physical Laboratory, India (NPLI). The reference grade hydrometers are calibrated and traceable to the primary solid density standard. The calibration has been done according to standard procedure based on Cuckow's Method and the reference grade hydrometers calibrated covers a wide range. The uncertainty of the reference grade hydrometers has been computed and corrections are also calculated for the scale readings, at which observations are taken.
Report on Computing and Networking in the Space Science Laboratory by the SSL Computer Committee
NASA Technical Reports Server (NTRS)
Gallagher, D. L. (Editor)
1993-01-01
The Space Science Laboratory (SSL) at Marshall Space Flight Center is a multiprogram facility. Scientific research is conducted in four discipline areas: earth science and applications, solar-terrestrial physics, astrophysics, and microgravity science and applications. Representatives from each of these discipline areas participate in a Laboratory computer requirements committee, which developed this document. The purpose is to establish and discuss Laboratory objectives for computing and networking in support of science. The purpose is also to lay the foundation for a collective, multiprogram approach to providing these services. Special recognition is given to the importance of the national and international efforts of our research communities toward the development of interoperable, network-based computer applications.
[Strategic thinking of the construction of national schistosomiasis laboratory network in China].
Qin, Zhi-Qiang; Xu, Jing; Feng, Ting; Zhu, Hong-Qing; Li, Shi-Zhu; Xiao, Ning; Zhou, Xiao-Nong
2013-08-01
A schistosomiasis laboratory network and its quality assurance system have been built and will be more and more perfect in China. This paper introduces the present situation of schistosomiasis diagnosis in China and expounds the basic ideas and the progress in the construction of schistosomiasis network platform. Furthermore, the face of schistosomiasis diagnosis network platform construction and operation of the challenge and the future work will be put forward in the latter part of this paper.
Farrar, Jerry W.; Long, H. Keith
1996-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for 6 standard reference samples--T-137 (trace constituents), M-136 (major constituents), N-47 (nutrient constituents), N-48 (nutrient constituents), P-25 (low ionic strength constituents), and Hg-21 (mercury)--that were distributed in October 1995 to 149 laboratories registered in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 136 of the laboratories were evaluated with respect to: overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Long, H. Keith; Farrar, Jerry W.
1994-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for five standard reference samples--T-129 (trace constituents), M-130 (major constituents), N-42 (nutrients), P-22 (low ionic strength), Hg-18(mercury),--that were distributed in April 1994 to 157 laboratories registered in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 133 of the laboratories were evaluated with respect to: overall laboratory performance and relative laboratory performance for each analyte in the five reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the five standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Long, H.K.; Farrar, J.W.
1993-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for seven standard reference samples--T-123 (trace constituents), T-125 (trace constituents), M-126 (major constituents), N-38 (nutrients), N-39 (Nutrients), P-20 (precipitation-low ionic strength), and Hg-16 (mercury)--that were distributed in April 1993 to 175 laboratories registered in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data received from 131 of the laboratories were evaluated with respect to: overall laboratory performance and relative laboratory performance for each analyte in the 7 reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the seven standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Farrar, Jerry W.; Chleboun, Kimberly M.
1999-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for 8 standard reference samples -- T-157 (trace constituents), M-150 (major constituents), N-61 (nutrient constituents), N-62 (nutrient constituents), P-32 (low ionic strength constituents), GWT-5 (ground-water trace constituents), GWM- 4 (ground-water major constituents),and Hg-28 (mercury) -- that were distributed in March 1999 to 120 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 111 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the seven reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the 8 standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Cavallaro, Kathleen F; Sandhu, Hardeep S; Hyde, Terri B; Johnson, Barbara W; Fischer, Marc; Mayer, Leonard W; Clark, Thomas A; Pallansch, Mark A; Yin, Zundong; Zuo, Shuyan; Hadler, Stephen C; Diorditsa, Serguey; Hasan, A S M Mainul; Bose, Anindya S; Dietz, Vance
2015-02-25
Surveillance for acute flaccid paralysis with laboratory confirmation has been a key strategy in the global polio eradication initiative, and the laboratory platform established for polio testing has been expanded in many countries to include surveillance for cases of febrile rash illness to identify measles and rubella cases. Vaccine-preventable disease surveillance is essential to detect outbreaks, define disease burden, guide vaccination strategies and assess immunization impact. Vaccines now exist to prevent Japanese encephalitis (JE) and some etiologies of bacterial meningitis. We evaluated the feasibility of expanding polio-measles surveillance and laboratory networks to detect bacterial meningitis and JE, using surveillance for acute meningitis-encephalitis syndrome in Bangladesh and China and acute encephalitis syndrome in India. We developed nine syndromic surveillance performance indicators based on international surveillance guidelines and calculated scores using supervisory visit reports, annual reports, and case-based surveillance data. Scores, variable by country and targeted disease, were highest for the presence of national guidelines, sustainability, training, availability of JE laboratory resources, and effectiveness of using polio-measles networks for JE surveillance. Scores for effectiveness of building on polio-measles networks for bacterial meningitis surveillance and specimen referral were the lowest, because of differences in specimens and techniques. Polio-measles surveillance and laboratory networks provided useful infrastructure for establishing syndromic surveillance and building capacity for JE diagnosis, but were less applicable for bacterial meningitis. Laboratory-supported surveillance for vaccine-preventable bacterial diseases will require substantial technical and financial support to enhance local diagnostic capacity. Published by Elsevier Ltd.
Evaluating Pseudorange Multipath at CGPS Stations Spanning Mexico
NASA Astrophysics Data System (ADS)
Vazquez, G.; Bennett, R. A.; Spinler, J. C.
2013-12-01
A research study was conducted in order to quantify and analyze the amount of pseudorange multipath at continuous Global Positioning System (CGPS) stations spanning Mexico. These CGPS stations are administered by a variety of organizations, including government agencies and public universities, and thus serve a wide range of positioning needs. Despite the diversity of the networks and their intended audiences, a core function of all of the networks is to provide a stable framework for high-precision positioning in support of diverse commercial and scientific applications. CGPS data from a large number of publicly available networks located in Mexico were studied. These include the RGNA (National Active Geodetic Network) administered by INEGI (National Institute of Statistics and Geography), the PBO network (Plate Boundary Observatory) funded by the National Science Foundation (NSF) and operated by UNAVCO (University NAVstar Consortium), the Southern California Integrated GPS Network (SCIGN), which is a collaboration effort of the United States Geological Survey (USGS), Scripps Institution of Oceanography and the Jet Propulsion Laboratory (JPL), the UNAM network, operated by the National Seismological System (SSN) and the Institute of Geophysics of the National Autonomous University of Mexico (UNAM), the Suominet Geodetic Network (SNG) and the CORS (Continuously Operating Reference Station) network, operated by the Federal Aviation Administration (FAA). A total of 54 CGPS stations were evaluated, where dual-frequency geodetic-grade receivers collected GPS data continuously during the period from 1994 to 2013. It is usually assumed that despite carefully selected locations, all CGPS stations are to some extent, affected by the presence of signal multipath. In addition, the geographic distribution of stations provides a nation-wide access to the International Terrestrial Reference Frame (ITRF). For real-time kinematic (RTK) and rapid static applications that depend on the pseudo-range observable, the accuracy with which a roaming user may locate their assets with respect to the ITRF may be limited by site-specific multipath. The issue is particularly critical for users depending on pseudorange measurements for 'real-time' (or 'near-real-time') kinematic GPS positioning, where ambiguity resolution is a critical step. Therefore, to identify the most and the least affected GPS stations we analyzed the averaged daily root mean square pseudorange multipath variations (MP1-RMS and MP2-RMS) for all feasible satellites tracked by the CGPS networks. We investigated the sources of multipath, including changes associated with hardware replacement (i.e., receiver and antenna type) and receiver firmware upgrades.
ERIC Educational Resources Information Center
Addessio, Barbara K.; And Others
Los Alamos National Laboratory (LANL) developed a model for school networking using Los Alamos Middle School as a testbed. The project was a collaborative effort between the school and the laboratory. The school secured administrative funding for hardware and software; and LANL provided the network architecture, installation, consulting, and…
Smart-DS: Synthetic Models for Advanced, Realistic Testing: Distribution Systems and Scenarios
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krishnan, Venkat K; Palmintier, Bryan S; Hodge, Brian S
The National Renewable Energy Laboratory (NREL) in collaboration with Massachusetts Institute of Technology (MIT), Universidad Pontificia Comillas (Comillas-IIT, Spain) and GE Grid Solutions, is working on an ARPA-E GRID DATA project, titled Smart-DS, to create: 1) High-quality, realistic, synthetic distribution network models, and 2) Advanced tools for automated scenario generation based on high-resolution weather data and generation growth projections. Through these advancements, the Smart-DS project is envisioned to accelerate the development, testing, and adoption of advanced algorithms, approaches, and technologies for sustainable and resilient electric power systems, especially in the realm of U.S. distribution systems. This talk will present themore » goals and overall approach of the Smart-DS project, including the process of creating the synthetic distribution datasets using reference network model (RNM) and the comprehensive validation process to ensure network realism, feasibility, and applicability to advanced use cases. The talk will provide demonstrations of early versions of synthetic models, along with the lessons learnt from expert engagements to enhance future iterations. Finally, the scenario generation framework, its development plans, and co-ordination with GRID DATA repository teams to house these datasets for public access will also be discussed.« less
Materials, processes, and environmental engineering network
NASA Technical Reports Server (NTRS)
White, Margo M.
1993-01-01
The Materials, Processes, and Environmental Engineering Network (MPEEN) was developed as a central holding facility for materials testing information generated by the Materials and Processes Laboratory. It contains information from other NASA centers and outside agencies, and also includes the NASA Environmental Information System (NEIS) and Failure Analysis Information System (FAIS) data. Environmental replacement materials information is a newly developed focus of MPEEN. This database is the NASA Environmental Information System, NEIS, which is accessible through MPEEN. Environmental concerns are addressed regarding materials identified by the NASA Operational Environment Team, NOET, to be hazardous to the environment. An environmental replacement technology database is contained within NEIS. Environmental concerns about materials are identified by NOET, and control or replacement strategies are formed. This database also contains the usage and performance characteristics of these hazardous materials. In addition to addressing environmental concerns, MPEEN contains one of the largest materials databases in the world. Over 600 users access this network on a daily basis. There is information available on failure analysis, metals and nonmetals testing, materials properties, standard and commercial parts, foreign alloy cross-reference, Long Duration Exposure Facility (LDEF) data, and Materials and Processes Selection List data.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Klise, Katherine A.; Murray, Regan; Bynum, Michael
Water utilities are vulnerable to a wide variety of human-caused and natural disasters. These disruptive events can result in loss of water service, contaminated water, pipe breaks, and failed equipment. Furthermore, long term changes in water supply and customer demand can have a large impact on the operating conditions of the network. The ability to maintain drinking water service during and following these types of events is critical. Simulation and analysis tools can help water utilities explore how their network will respond to disruptive events and plan effective mitigation strategies. The U.S. Environmental Protection Agency and Sandia National Laboratories aremore » developing new software tools to meet this need. The Water Network Tool for Resilience (WNTR, pronounced winter) is a Python package designed to help water utilities investigate resilience of water distribution systems over a wide range of hazardous scenarios and to evaluate resilience-enhancing actions. The following documentation includes installation instructions and examples, description of software features, and software license. It is assumed that the reader is familiar with the Python Programming Language. References are included for additional background on software components. Online documentation, hosted at http://wntr.readthedocsio/, will be updated as new features are added. The online version includes API documentation and information for developers.« less
Harmonization in laboratory medicine: Requests, samples, measurements and reports.
Plebani, Mario
2016-01-01
In laboratory medicine, the terms "standardization" and "harmonization" are frequently used interchangeably as the final goal is the same: the equivalence of measurement results among different routine measurement procedures over time and space according to defined analytical and clinical quality specifications. However, the terms define two distinct, albeit closely linked, concepts based on traceability principles. The word "standardization" is used when results for a measurement are equivalent and traceable to the International System of Units (SI) through a high-order primary reference material and/or a reference measurement procedure (RMP). "Harmonization" is generally used when results are equivalent, but neither a high-order primary reference material nor a reference measurement procedure is available. Harmonization is a fundamental aspect of quality in laboratory medicine as its ultimate goal is to improve patient outcomes through the provision of accurate and actionable laboratory information. Patients, clinicians and other healthcare professionals assume that clinical laboratory tests performed by different laboratories at different times on the same sample and specimen can be compared, and that results can be reliably and consistently interpreted. Unfortunately, this is not necessarily the case, because many laboratory test results are still highly variable and poorly standardized and harmonized. Although the initial focus was mainly on harmonizing and standardizing analytical processes and methods, the scope of harmonization now also includes all other aspects of the total testing process (TTP), such as terminology and units, report formats, reference intervals and decision limits as well as tests and test profiles, requests and criteria for interpretation. Several projects and initiatives aiming to improve standardization and harmonization in the testing process are now underway. Laboratory professionals should therefore step up their efforts to provide interchangeable and comparable laboratory information in order to ultimately assure better diagnosis and treatment in patient care.
Issues in PCS interoperability and Internetworking
NASA Technical Reports Server (NTRS)
Dean, Richard A.; Estabrook, Polly
1995-01-01
This paper is an expansion of an earlier paper on Satellite/Terrestrial PCS which addressed issues for interoperability that included Networks, Services, Voice Coders and Mobility/Security. This paper focuses on the narrower topic of Network Reference Models and associated interfaces and protocols. The network reference models are addressed from the perspective of the User, the Cellular Carrier, the PSN Carrier, and the Radio Vendor. Each perspective is presented in the way these systems have evolved. The TIA TR46/GSM reference model will be reviewed. Variations in the use of this model that are prevalent in the industry will be discussed. These are the North American Cellular networks, the GSM networks, and the North American Carriers/Bellcore perspective. The paper concludes with the presentation of issues that develop from looking at merging satellite service into a world of many different networks.
As part of the Environmental Response Laboratory Network, the National Air and Radiation Environmental Laboratory (NAREL) here provides your laboratory with access to radiation-specific laboratory guidance documents and training courses.
Ortolon, Ken
2011-04-01
Patients who pay for out-of-network benefits should have the right to use those benefits, the Texas Medical Association believes. But TMA fears that a new CIGNA policy is designed to discourage enrollees from using their out-of-network benefits and will create huge administrative hassles for physicians who refer patients to out-of-network providers. TMA officials say the policy requires physicians to document that they told patients that they are being referred to out-of-network providers and to keep the documentation in their records indefinitely.
Embedded Efficiency: A Social Networks Approach to Popular Support and Dark Network Structure
2016-03-01
Raab in “Dark networks as problems ,” (2003) where dark refers to illegal and, covert and bright refers to legal and overt. Throughout this report these...Milward, Jörg Raab, “Dark Networks as Organizational Problems : Elements of a Theory,” International Public Management Journal 9, no.3 ( 2006): 333–360...Emirbayer and Jeff Goodwin, “Network Analysis, Culture and the Problem of Agency,” American Journal of Sociology Vol. 99, No. 6 (May 1994): 1436. 35 Ibid
Kainz, Hans; Lloyd, David G; Walsh, Henry P J; Carty, Christopher P
2016-05-01
In motion analysis, pelvis angles are conventionally calculated as the rotations between the pelvis and laboratory reference frame. This approach assumes that the participant's motion is along the anterior-posterior laboratory reference frame axis. When this assumption is violated interpretation of pelvis angels become problematic. In this paper a new approach for calculating pelvis angles based on the rotations between the pelvis and an instantaneous progression reference frame was introduced. At every time-point, the tangent to the trajectory of the midpoint of the pelvis projected into the horizontal plane of the laboratory reference frame was used to define the anterior-posterior axis of the instantaneous progression reference frame. This new approach combined with the rotation-obliquity-tilt rotation sequence was compared to the conventional approach using the rotation-obliquity-tilt and tilt-obliquity-rotation sequences. Four different movement tasks performed by eight healthy adults were analysed. The instantaneous progression reference frame approach was the only approach that showed reliable and anatomically meaningful results for all analysed movement tasks (mean root-mean-square-differences below 5°, differences in pelvis angles at pre-defined gait events below 10°). Both rotation sequences combined with the conventional approach led to unreliable results as soon as the participant's motion was not along the anterior-posterior laboratory axis (mean root-mean-square-differences up to 30°, differences in pelvis angles at pre-defined gait events up to 45°). The instantaneous progression reference frame approach enables the gait analysis community to analysis pelvis angles for movements that do not follow the anterior-posterior axis of the laboratory reference frame. Copyright © 2016 Elsevier B.V. All rights reserved.
Whitfield, Paul H.; Burn, Donald H.; Hannaford, Jamie; Higgins, Hélène; Hodgkins, Glenn A.; Marsh, Terry; Looser, Ulrich
2012-01-01
Identifying climate-driven trends in river flows on a global basis is hampered by a lack of long, quality time series data for rivers with relatively undisturbed regimes. This is a global problem compounded by the lack of support for essential long-term monitoring. Experience demonstrates that, with clear strategic objectives, and the support of sponsoring organizations, reference hydrologic networks can constitute an exceptionally valuable data source to effectively identify, quantify and interpret hydrological change—the speed and magnitude of which is expected to a be a primary driver of water management and flood alleviation strategies through the future—and for additional applications. Reference hydrologic networks have been developed in many countries in the past few decades. These collections of streamflow gauging stations, that are maintained and operated with the intention of observing how the hydrology of watersheds responds to variations in climate, are described. The status of networks under development is summarized. We suggest a plan of actions to make more effective use of this collection of networks.
Evolution of a residue laboratory network and the management tools for monitoring its performance.
Lins, E S; Conceição, E S; Mauricio, A De Q
2012-01-01
Since 2005 the National Residue & Contaminants Control Plan (NRCCP) in Brazil has been considerably enhanced, increasing the number of samples, substances and species monitored, and also the analytical detection capability. The Brazilian laboratory network was forced to improve its quality standards in order to comply with the NRCP's own evolution. Many aspects such as the limits of quantification (LOQs), the quality management systems within the laboratories and appropriate method validation are in continuous improvement, generating new scenarios and demands. Thus, efficient management mechanisms for monitoring network performance and its adherence to the established goals and guidelines are required. Performance indicators associated to computerised information systems arise as a powerful tool to monitor the laboratories' activity, making use of different parameters to describe this activity on a day-to-day basis. One of these parameters is related to turnaround times, and this factor is highly affected by the way each laboratory organises its management system, as well as the regulatory requirements. In this paper a global view is presented of the turnaround times related to the type of analysis, laboratory, number of samples per year, type of matrix, country region and period of the year, all these data being collected from a computerised system called SISRES. This information gives a solid background to management measures aiming at the improvement of the service offered by the laboratory network.
fMRI evidence for strategic decision-making during resolution of pronoun reference.
McMillan, Corey T; Clark, Robin; Gunawardena, Delani; Ryant, Neville; Grossman, Murray
2012-04-01
Pronouns are extraordinarily common in daily language yet little is known about the neural mechanisms that support decisions about pronoun reference. We propose a large-scale neural network for resolving pronoun reference that consists of two components. First, a core language network in peri-Sylvian cortex supports syntactic and semantic resources for interpreting pronoun meaning in sentences. Second, a frontal-parietal network that supports strategic decision-making is recruited to support probabilistic and risk-related components of resolving a pronoun's referent. In an fMRI study of healthy young adults, we observed activation of left inferior frontal and superior temporal cortex, consistent with a language network. We also observed activation of brain regions not associated with traditional language areas. By manipulating the context of the pronoun, we were able to demonstrate recruitment of dorsolateral prefrontal cortex during probabilistic evaluation of a pronoun's reference, and orbital frontal activation when a pronoun must adopt a risky referent. Together, these findings are consistent with a two-component model for resolving a pronoun's reference that includes neuroanatomic regions supporting core linguistic and decision-making mechanisms. Copyright © 2012 Elsevier Ltd. All rights reserved.
Miller, Susan M; Ferrarotto, Catherine L; Vlahovich, Slavica; Wilkins, Ruth C; Boreham, Douglas R; Dolling, Jo-Anna
2007-07-01
To test the ability of the cytogenetic emergency network (CEN) of laboratories, currently under development across Canada, to provide rapid biological dosimetry using the dicentric assay for triage assessment, that could be implemented in the event of a large-scale radiation/nuclear emergency. A workshop was held in May 2004 in Toronto, Canada, to introduce the concept of CEN and recruit clinical cytogenetic laboratories at hospitals across the country. Slides were prepared for dicentric assay analysis following in vitro irradiation of blood to a range of gamma-ray doses. A minimum of 50 metaphases per slide were analyzed by 41 people at 22 different laboratories to estimate the exposure level. Dose estimates were calculated based on a dose response curve generated at Health Canada. There were a total of 104 dose estimates and 96 (92.3%) of them fell within the expected range using triage scoring criteria. Half of the laboratories analyzed 50 metaphases in = 1 hour and the time to score them was proportional to dose. The capacity and scoring expertise of the various participating laboratories were found to be generally acceptable. The dose estimates generated through triage scoring by this network were acceptable for emergency biological dosimetry. When this network is fully operational, it will be the first of its kind in Canada able to respond to radiological/nuclear emergencies by providing triage quality biological dosimetry for a large number of samples. This network represents an alternate expansion of existing international emergency biological dosimetry cytogenetic networks.
fMRI Evidence for Strategic Decision-Making during Resolution of Pronoun Reference
ERIC Educational Resources Information Center
McMillan, Corey T.; Clark, Robin; Gunawardena, Delani; Ryant, Neville; Grossman, Murray
2012-01-01
Pronouns are extraordinarily common in daily language yet little is known about the neural mechanisms that support decisions about pronoun reference. We propose a large-scale neural network for resolving pronoun reference that consists of two components. First, a core language network in peri-Sylvian cortex supports syntactic and semantic…
Gröbner, Julian; Rembges, Diana; Bais, Alkiviadis F; Blumthaler, Mario; Cabot, Thierry; Josefsson, Weine; Koskela, Tapani; Thorseth, Trond M; Webb, Ann R; Wester, Ulf
2002-07-20
A program for quality assurance of reference standards has been initiated among nine solar-UV monitoring laboratories. By means of a traveling lamp package that comprises several 1000-W ANSI code DXW-type quartz-halogen lamps, a 0.1-ohm shunt, and a 6-1/2 digit voltmeter, the irradiance scales used by the nine laboratories were compared with one another; a relative uncertainty of 1.2% was found. The comparison of 15 reference standards yielded differences of as much as 9%; the average difference was less than 3%.
Thelaus, Johanna; Lindberg, Anna; Thisted Lambertz, Susanne; Byström, Mona; Forsman, Mats; Lindmark, Hans; Knutsson, Rickard; Båverud, Viveca; Bråve, Andreas; Jureen, Pontus; Lundin Zumpe, Annelie; Melefors, Öjar
The Swedish Forum for Biopreparedness Diagnostics (FBD) is a network that fosters collaboration among the 4 agencies with responsibility for the laboratory diagnostics of high-consequence pathogens, covering animal health and feed safety, food safety, public health and biodefense, and security. The aim of the network is to strengthen capabilities and capacities for diagnostics at the national biosafety level-3 (BSL-3) laboratories to improve Sweden's biopreparedness, in line with recommendations from the EU and WHO. Since forming in 2007, the FBD network has contributed to the harmonization of diagnostic methods, equipment, quality assurance protocols, and biosafety practices among the national BSL-3 laboratories. Lessons learned from the network include: (1) conducting joint projects with activities such as method development and validation, ring trials, exercises, and audits has helped to build trust and improve communication among participating agencies; (2) rotating the presidency of the network steering committee has fostered trust and commitment from all agencies involved; and (3) planning for the implementation of project outcomes is important to maintain gained competencies in the agencies over time. Contacts have now been established with national agencies of the other Nordic countries, with an aim to expanding the collaboration, broadening the network, finding synergies in new areas, strengthening the ability to share resources, and consolidating long-term financing in the context of harmonized European biopreparedness.
Lindberg, Anna; Thisted Lambertz, Susanne; Byström, Mona; Forsman, Mats; Lindmark, Hans; Knutsson, Rickard; Båverud, Viveca; Bråve, Andreas; Jureen, Pontus; Lundin Zumpe, Annelie; Melefors, Öjar
2017-01-01
The Swedish Forum for Biopreparedness Diagnostics (FBD) is a network that fosters collaboration among the 4 agencies with responsibility for the laboratory diagnostics of high-consequence pathogens, covering animal health and feed safety, food safety, public health and biodefense, and security. The aim of the network is to strengthen capabilities and capacities for diagnostics at the national biosafety level-3 (BSL-3) laboratories to improve Sweden's biopreparedness, in line with recommendations from the EU and WHO. Since forming in 2007, the FBD network has contributed to the harmonization of diagnostic methods, equipment, quality assurance protocols, and biosafety practices among the national BSL-3 laboratories. Lessons learned from the network include: (1) conducting joint projects with activities such as method development and validation, ring trials, exercises, and audits has helped to build trust and improve communication among participating agencies; (2) rotating the presidency of the network steering committee has fostered trust and commitment from all agencies involved; and (3) planning for the implementation of project outcomes is important to maintain gained competencies in the agencies over time. Contacts have now been established with national agencies of the other Nordic countries, with an aim to expanding the collaboration, broadening the network, finding synergies in new areas, strengthening the ability to share resources, and consolidating long-term financing in the context of harmonized European biopreparedness. PMID:28805472
An evaluation of the distribution of sexual references among "Top 8" MySpace friends.
Moreno, Megan A; Brockman, Libby; Rogers, Cara B; Christakis, Dimitri A
2010-10-01
To evaluate whether online friends of adolescents who display sexual references on a social networking site also display references. The method used was content analysis. The result of this study was that adolescents who displayed explicit sexual references were more likely to have online friends who displayed references. Thus, social networking sites present new opportunities to investigate adolescent sexual behavior. Copyright © 2010 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.
[Information system of the national network of public health laboratories in Peru (Netlab)].
Vargas-Herrera, Javier; Segovia-Juarez, José; Garro Nuñez, Gladys María
2015-01-01
Clinical laboratory information systems produce improvements in the quality of information, reduce service costs, and diminish wait times for results, among other things. In the construction process of this information system, the National Institute of Health (NIH) of Peru has developed and implemented a web-based application to communicate to health personnel (laboratory workers, epidemiologists, health strategy managers, physicians, etc.) the results of laboratory tests performed at the Peruvian NIH or in the laboratories of the National Network of Public Health Laboratories which is called NETLAB. This article presents the experience of implementing NETLAB, its current situation, perspectives of its use, and its contribution to the prevention and control of diseases in Peru.
Study of mobile satellite network based on GEO/LEO satellite constellation
NASA Astrophysics Data System (ADS)
Hu, Xiulin; Zeng, Yujiang; Wang, Ying; Wang, Xianhui
2005-11-01
Mobile satellite network with Inter Satellite Links (ISLs), which consists of non-geostationary satellites, has the characteristic of network topology's variability. This is a great challenge to the design and management of mobile satellite network. This paper analyzes the characteristics of mobile satellite network, takes multimedia Quality of Service (QoS) as the chief object and presents a reference model based on Geostationary Earth Orbit (GEO)/ Low Earth Orbit (LEO) satellite constellation which adapts to the design and management of mobile satellite network. In the reference model, LEO satellites constitute service subnet with responsibility for the access, transmission and switch of the multimedia services for mobile users, while GEO satellites constitute management subnet taking on the centralized management to service subnet. Additionally ground control centre realizes the whole monitoring and control via management subnet. Comparing with terrestrial network, the above reference model physically separates management subnet from service subnet, which not only enhances the advantage of centralized management but also overcomes the shortcoming of low reliability in terrestrial network. Routing of mobile satellite network based on GEO/LEO satellite constellation is also discussed in this paper.
The Air Force's central reference laboratory: maximizing service while minimizing cost.
Armbruster, D A
1991-11-01
The Laboratory Services Branch (Epi Lab) of the Epidemiology Division, Brooks AFB, Texas, is designated by regulation to serve as the Air Force's central reference laboratory, providing clinical laboratory testing support to all Air Force medical treatment facilities (MTFs). Epi Lab recognized that it was not offering the MTFs a service comparable to civilian reference laboratories and that, as a result, the Air Force medical system was spending hundreds of thousands of dollars yearly for commercial laboratory support. An in-house laboratory upgrade program was proposed to and approved by the USAF Surgeon General, as a Congressional Efficiencies Add project, to launch a two-phase initiative consisting of a 1-year field trial of 30 MTFs, followed by expansion to another 60 MTFs. Major components of the program include overnight air courier service to deliver patient samples to Epi Lab, a mainframe computer laboratory information system and electronic reporting of results to the MTFs throughout the CONUS. Application of medical marketing concepts and the Total Quality Management (TQM) philosophy allowed Epi to provide dramatically enhanced reference service at a cost savings of about $1 million to the medical system. The Epi Lab upgrade program represents an innovative problem-solving approach, combining technical and managerial improvements, resulting in substantial patient care service and financial dividends. It serves as an example of successful application of TQM and marketing within the military medical system.
NASA Astrophysics Data System (ADS)
Pahlavani, P.; Gholami, A.; Azimi, S.
2017-09-01
This paper presents an indoor positioning technique based on a multi-layer feed-forward (MLFF) artificial neural networks (ANN). Most of the indoor received signal strength (RSS)-based WLAN positioning systems use the fingerprinting technique that can be divided into two phases: the offline (calibration) phase and the online (estimation) phase. In this paper, RSSs were collected for all references points in four directions and two periods of time (Morning and Evening). Hence, RSS readings were sampled at a regular time interval and specific orientation at each reference point. The proposed ANN based model used Levenberg-Marquardt algorithm for learning and fitting the network to the training data. This RSS readings in all references points and the known position of these references points was prepared for training phase of the proposed MLFF neural network. Eventually, the average positioning error for this network using 30% check and validation data was computed approximately 2.20 meter.
A time reference distribution concept for a time division communication network
NASA Technical Reports Server (NTRS)
Stover, H. A.
1973-01-01
Starting with an assumed ideal network having perfect clocks at every node and known fixed transmission delays between nodes, the effects of adding tolerances to both transmission delays and nodal clocks is described. The advantages of controlling tolerances on time rather than frequency are discussed. Then a concept is presented for maintaining these tolerances on time throughout the network. This concept, called time reference distribution, is a systematic technique for distributing time reference to all nodes of the network. It is reliable, survivable and possesses many other desirable characteristics. Some of its features such as an excellent self monitoring capability will be pointed out. Some preliminary estimates of the accuracy that might be expected are developed and there is a brief discussion of the impact upon communication system costs. Time reference distribution is a concept that appears very attractive. It has not had experimental evaluation and has not yet been endorsed for use in any communication network.
Age and sex variation in serum albumin concentration: an observational study.
Weaving, Gary; Batstone, Gifford F; Jones, Richard G
2016-01-01
In the UK, a common reference interval for serum albumin is widely used irrespective of age or sex. Implicit in this is that laboratories produce analytically similar results. This paper challenges the validity of this approach. A three-week collection of results sent to all primary care centres in England has been analysed by age, sex and laboratory. In all, 1,079,193 serum albumin reports were included in this analysis. The mean population serum albumin concentration increases to peak at around age 20 years and then decreases with increasing age. Values in females decrease more rapidly but become close to male values at 60 years. The variation between laboratories was large and potentially clinically significant. Reference intervals for serum albumin should be stratified by age and sex. Until there is greater methodological standardization, laboratories should determine their own reference intervals and not accept a single consensus reference interval. © The Author(s) 2015.
Ludtke, Amy S.; Woodworth, Mark T.; Marsh, Philip S.
2000-01-01
The U.S. Geological Survey operates a quality-assurance program based on the analyses of reference samples for two laboratories: the National Water Quality Laboratory and the Quality of Water Service Unit. Reference samples that contain selected inorganic, nutrient, and low-level constituents are prepared and submitted to the laboratory as disguised routine samples. The program goal is to estimate precision and bias for as many analytical methods offered by the participating laboratories as possible. Blind reference samples typically are submitted at a rate of 2 to 5 percent of the annual environmental-sample load for each constituent. The samples are distributed to the laboratories throughout the year. The reference samples are subject to the identical laboratory handling, processing, and analytical procedures as those applied to environmental samples and, therefore, have been used as an independent source to verify bias and precision of laboratory analytical methods and ambient water-quality measurements. The results are stored permanently in the National Water Information System and the Blind Sample Project's data base. During water year 1998, 95 analytical procedures were evaluated at the National Water Quality Laboratory and 63 analytical procedures were evaluated at the Quality of Water Service Unit. An overall evaluation of the inorganic and low-level constituent data for water year 1998 indicated 77 of 78 analytical procedures at the National Water Quality Laboratory met the criteria for precision. Silver (dissolved, inductively coupled plasma-mass spectrometry) was determined to be imprecise. Five of 78 analytical procedures showed bias throughout the range of reference samples: chromium (dissolved, inductively coupled plasma-atomic emission spectrometry), dissolved solids (dissolved, gravimetric), lithium (dissolved, inductively coupled plasma-atomic emission spectrometry), silver (dissolved, inductively coupled plasma-mass spectrometry), and zinc (dissolved, inductively coupled plasma-mass spectrometry). At the National Water Quality Laboratory during water year 1998, lack of precision was indicated for 2 of 17 nutrient procedures: ammonia as nitrogen (dissolved, colorimetric) and orthophosphate as phosphorus (dissolved, colorimetric). Bias was indicated throughout the reference sample range for ammonia as nitrogen (dissolved, colorimetric, low level) and nitrate plus nitrite as nitrogen (dissolved, colorimetric, low level). All analytical procedures tested at the Quality of Water Service Unit during water year 1998 met the criteria for precision. One of the 63 analytical procedures indicated a bias throughout the range of reference samples: aluminum (whole-water recoverable, inductively coupled plasma-atomic emission spectrometry, trace).
In vitro vaccine potency testing: a proposal for reducing animal use for requalification testing.
Brown, K; Stokes, W
2012-01-01
This paper proposes a program under which the use of animals for requalification of in vitro potency tests could be eliminated. Standard References (USDA/CVB nomenclature) would be developed, characterized, stored and monitored by selected reference laboratories worldwide. These laboratories would employ scientists skilled in protein and glycoprotein chemistry and equipped with state-of-the-art instruments for required analyses. After Standard References are established, the reference laboratories would provide them to the animal health industry as "gold standards". Companies would then establish and validate a correlation between the Standard Reference and the company Master Reference (USDA/CVB nomenclature) using an internal in vitro assay. After this correlation is established, the company could use the Standard References for qualifying, monitoring and requalifying company Master References without the use of animals. Such a program would eliminate the need for animals for requalification of Master References and the need for each company to develop and validate a battery of Master Reference Monitoring assays. It would also provide advantages in terms of reduced costs and reduced time for requalification testing. As such it would provide a strong incentive for companies to develop and use in vitro assays for potency testing.
Manganese recycling in the United States in 1998
Jones, Thomas S.
2003-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-163 (trace constituents), M-156 (major constituents), N-67 (nutrient constituents), N-68 (nutrient constituents), P-35 (low ionic strength constituents), and Hg-31 (mercury) -- that were distributed in October 2000 to 126 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 122 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Nia, Yacine; Mutel, Isabelle; Assere, Adrien; Lombard, Bertrand; Auvray, Frederic; Hennekinne, Jacques-Antoine
2016-04-13
Staphylococcal food poisoning outbreaks are a major cause of foodborne illnesses in Europe and their notifications have been mandatory since 2005. Even though the European regulation on microbiological criteria for food defines a criterion on staphylococcal enterotoxin (SE) only in cheese and dairy products, European Food Safety Authority (EFSA) data reported that various types of food matrices are involved in staphylococcal food poisoning outbreaks. The European Screening Method (ESM) of European Union Reference Laboratory for Coagulase Positive Staphylococci (EURL CPS) was validated in 2011 for SE detection in food matrices and is currently the official method used for screening purposes in Europe. In this context, EURLCPS is annually organizing Inter-Laboratory Proficiency Testing Trials (ILPT) to evaluate the competency of the European countries' National Reference Laboratories (NRLs) to analyse SE content in food matrices. A total of 31 NRLs representing 93% of European countries participated in these ILPTs. Eight food matrices were used for ILPT over the period 2013-2015, including cheese, freeze-dried cheese, tuna, mackerel, roasted chicken, ready-to-eat food, milk, and pastry. Food samples were spiked with four SE types (i.e., SEA, SEC, SED, and SEE) at various concentrations. Homogeneity and stability studies showed that ILPT samples were both homogeneous and stable. The analysis of results obtained by participants for a total of 155 blank and 620 contaminated samples allowed for evaluation of trueness (>98%) and specificity (100%) of ESM. Further to the validation study of ESM carried out in 2011, these three ILPTs allowed for the assessment of the proficiency of the NRL network and the performance of ESM on a large variety of food matrices and samples. The ILPT design presented here will be helpful for the organization of ILPT on SE detection by NRLs or other expert laboratories.
GHSI EMERGENCY RADIONUCLIDE BIOASSAY LABORATORY NETWORK - SUMMARY OF THE SECOND EXERCISE.
Li, Chunsheng; Bartizel, Christine; Battisti, Paolo; Böttger, Axel; Bouvier, Céline; Capote-Cuellar, Antonio; Carr, Zhanat; Hammond, Derek; Hartmann, Martina; Heikkinen, Tarja; Jones, Robert L; Kim, Eunjoo; Ko, Raymond; Koga, Roberto; Kukhta, Boris; Mitchell, Lorna; Morhard, Ryan; Paquet, Francois; Quayle, Debora; Rulik, Petr; Sadi, Baki; Sergei, Aleksanin; Sierra, Inmaculada; de Oliveira Sousa, Wanderson; Szab, Gyula
2017-05-01
The Global Health Security Initiative (GHSI) established a laboratory network within the GHSI community to develop collective surge capacity for radionuclide bioassay in response to a radiological or nuclear emergency as a means of enhancing response capability, health outcomes and community resilience. GHSI partners conducted an exercise in collaboration with the WHO Radiation Emergency Medical Preparedness and Assistance Network and the IAEA Response and Assistance Network, to test the participating laboratories (18) for their capabilities in in vitro assay of biological samples, using a urine sample spiked with multiple high-risk radionuclides (90Sr, 106Ru, 137Cs, and 239Pu). Laboratories were required to submit their reports within 72 h following receipt of the sample, using a pre-formatted template, on the procedures, methods and techniques used to identify and quantify the radionuclides in the sample, as well as the bioassay results with a 95% confidence interval. All of the participating laboratories identified and measured all or some of the radionuclides in the sample. However, gaps were identified in both the procedures used to assay multiple radionuclides in one sample, as well as in the methods or techniques used to assay specific radionuclides in urine. Two-third of the participating laboratories had difficulties in determining all the radionuclides in the sample. Results from this exercise indicate that challenges remain with respect to ensuring that results are delivered in a timely, consistent and reliable manner to support medical interventions. Laboratories within the networks are encouraged to work together to develop and maintain collective capabilities and capacity for emergency bioassay, which is an important component of radiation emergency response. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
GHSI Emergency Radionuclide Bioassay Laboratory Network - Summary of the Second Exercise
Li, Chunsheng; Bartizel, Christine; Battisti, Paolo; Böttger, Axel; Bouvier, Céline; Capote-Cuellar, Antonio; Carr, Zhanat; Hammond, Derek; Hartmann, Martina; Heikkinen, Tarja; Jones, Robert L.; Kim, Eunjoo; Ko, Raymond; Koga, Roberto; Kukhta, Boris; Mitchell, Lorna; Morhard, Ryan; Paquet, Francois; Quayle, Debora; Rulik, Petr; Sadi, Baki; Sergei, Aleksanin; Sierra, Inmaculada; de Oliveira Sousa, Wanderson; Szabó, Gyula
2017-01-01
The Global Health Security Initiative (GHSI) established a laboratory network within the GHSI community to develop collective surge capacity for radionuclide bioassay in response to a radiological or nuclear emergency as a means of enhancing response capability, health outcomes and community resilience. GHSI partners conducted an exercise in collaboration with the WHO REMPAN (Radiation Emergency Medical Preparedness and Assistance Network) and the IAEA RANET (Response and Assistance Network), to test the participating laboratories (18) for their capabilities in in vitro assay of biological samples, using a urine sample spiked with multiple high-risk radionuclides (90Sr, 106Ru, 137Cs, and 239Pu). Laboratories were required to submit their reports within 72 hours following receipt of the sample, using a pre-formatted template, on the procedures, methods and techniques used to identify and quantify the radionuclides in the sample, as well as the bioassay results with a 95% confidence interval. All of the participating laboratories identified and measured all or some of the radionuclides in the sample. However, gaps were identified in both the procedures used to assay multiple radionuclides in one sample, as well as in the methods or techniques used to assay specific radionuclides in urine. Two third of the participating laboratories had difficulties in determining all the radionuclides in the sample. Results from this exercise indicate that challenges remain with respect to ensuring that results are delivered in a timely, consistent and reliable manner to support medical interventions. Laboratories within the networks are encouraged to work together to develop and maintain collective capabilities and capacity for emergency bioassay, which is an important component of radiation emergency response. PMID:27574317
Cavallaro, Kathleen F.; Sandhu, Hardeep S.; Hyde, Terri B.; Johnson, Barbara W.; Fischer, Marc; Mayer, Leonard W.; Clark, Thomas A.; Pallansch, Mark A.; Yin, Zundong; Zuo, Shuyan; Hadler, Stephen C.; Diorditsa, Serguey; Hasan, A.S.M. Mainul; Bose, Anindya S.; Dietz, Vance
2016-01-01
Background Surveillance for acute flaccid paralysis with laboratory confirmation has been a key strategy in the global polio eradication initiative, and the laboratory platform established for polio testing has been expanded in many countries to include surveillance for cases of febrile rash illness to identify measles and rubella cases. Vaccine-preventable disease surveillance is essential to detect outbreaks, define disease burden, guide vaccination strategies and assess immunization impact. Vaccines now exist to prevent Japanese encephalitis (JE) and some etiologies of bacterial meningitis. Methods We evaluated the feasibility of expanding polio–measles surveillance and laboratory networks to detect bacterial meningitis and JE, using surveillance for acute meningitis-encephalitis syndrome in Bangladesh and China and acute encephalitis syndrome in India. We developed nine syndromic surveillance performance indicators based on international surveillance guidelines and calculated scores using supervisory visit reports, annual reports, and case-based surveillance data. Results Scores, variable by country and targeted disease, were highest for the presence of national guidelines, sustainability, training, availability of JE laboratory resources, and effectiveness of using polio–measles networks for JE surveillance. Scores for effectiveness of building on polio–measles networks for bacterial meningitis surveillance and specimen referral were the lowest, because of differences in specimens and techniques. Conclusions Polio–measles surveillance and laboratory networks provided useful infrastructure for establishing syndromic surveillance and building capacity for JE diagnosis, but were less applicable for bacterial meningitis. Laboratory-supported surveillance for vaccine-preventable bacterial diseases will require substantial technical and financial support to enhance local diagnostic capacity. PMID:25597940
Analysis of on-line clinical laboratory manuals and practical recommendations.
Beckwith, Bruce; Schwartz, Robert; Pantanowitz, Liron
2004-04-01
On-line clinical laboratory manuals are a valuable resource for medical professionals. To our knowledge, no recommendations currently exist for their content or design. To analyze publicly accessible on-line clinical laboratory manuals and to propose guidelines for their content. We conducted an Internet search for clinical laboratory manuals written in English with individual test listings. Four individual test listings in each manual were evaluated for 16 data elements, including sample requirements, test methodology, units of measure, reference range, and critical values. Web sites were also evaluated for supplementary information and search functions. We identified 48 on-line laboratory manuals, including 24 academic or community hospital laboratories and 24 commercial or reference laboratories. All manuals had search engines and/or test indices. No single manual contained all 16 data elements evaluated. An average of 8.9 (56%) elements were present (range, 4-14). Basic sample requirements (specimen and volume needed) were the elements most commonly present (98% of manuals). The frequency of the remaining data elements varied from 10% to 90%. On-line clinical laboratory manuals originate from both hospital and commercial laboratories. While most manuals were user-friendly and contained adequate specimen-collection information, other important elements, such as reference ranges, were frequently absent. To ensure that clinical laboratory manuals are of maximal utility, we propose the following 13 data elements be included in individual test listings: test name, synonyms, test description, test methodology, sample requirements, volume requirements, collection guidelines, transport guidelines, units of measure, reference range, critical values, test availability, and date of latest revision.
[The requirements of standard and conditions of interchangeability of medical articles].
Men'shikov, V V; Lukicheva, T I
2013-11-01
The article deals with possibility to apply specific approaches under evaluation of interchangeability of medical articles for laboratory analysis. The development of standardized analytical technologies of laboratory medicine and formulation of requirements of standards addressed to manufacturers of medical articles the clinically validated requirements are to be followed. These requirements include sensitivity and specificity of techniques, accuracy and precision of research results, stability of reagents' quality in particular conditions of their transportation and storage. The validity of requirements formulated in standards and addressed to manufacturers of medical articles can be proved using reference system, which includes master forms and standard samples, reference techniques and reference laboratories. This approach is supported by data of evaluation of testing systems for measurement of level of thyrotrophic hormone, thyroid hormones and glycated hemoglobin HB A1c. The versions of testing systems can be considered as interchangeable only in case of results corresponding to the results of reference technique and comparable with them. In case of absence of functioning reference system the possibilities of the Joined committee of traceability in laboratory medicine make it possible for manufacturers of reagent sets to apply the certified reference materials under development of manufacturing of sets for large listing of analytes.
Armored RNA as Virus Surrogate in a Real-Time Reverse Transcriptase PCR Assay Proficiency Panel
Hietala, S. K.; Crossley, B. M.
2006-01-01
In recent years testing responsibilities for high-consequence pathogens have been expanded from national reference laboratories into networks of local and regional laboratories in order to support enhanced disease surveillance and to test for surge capacity. This movement of testing of select agents and high-consequence pathogens beyond reference laboratories introduces a critical need for standardized, noninfectious surrogates of disease agents for use as training and proficiency test samples. In this study, reverse transcription-PCR assay RNA targets were developed and packaged as armored RNA for use as a noninfectious, quantifiable synthetic substitute for four high-consequence animal pathogens: classical swine fever virus; foot-and-mouth disease virus; vesicular stomatitis virus, New Jersey serogroup; and vesicular stomatitis virus, Indiana serogroup. Armored RNA spiked into oral swab fluid specimens mimicked virus-positive clinical material through all stages of the reverse transcription-PCR testing process, including RNA recovery by four different commercial extraction procedures, reverse transcription, PCR amplification, and real-time detection at target concentrations consistent with the dynamic ranges of the existing real-time PCR assays. The armored RNA concentrations spiked into the oral swab fluid specimens were stable under storage conditions selected to approximate the extremes of time and temperature expected for shipping and handling of proficiency panel samples, including 24 h at 37°C and 2 weeks at temperatures ranging from ambient room temperature to −70°C. The analytic test performance, including the reproducibility over the dynamic range of the assays, indicates that armored RNA can provide a noninfectious, quantifiable, and stable virus surrogate for specific assay training and proficiency test purposes. PMID:16390950
Evaluation of Toxoplasma ELITe MGB Real-Time PCR Assay for Diagnosis of Toxoplasmosis
Brenier-Pinchart, Marie-Pierre; Yera, Hélène; Belaz, Sorya; Varlet-Marie, Emmanuelle; Bastien, Patrick
2017-01-01
ABSTRACT Molecular diagnosis of congenital toxoplasmosis or disseminated toxoplasmosis is based mainly on PCR. The repeated DNA element rep529 has become the main DNA target used in most PCR methods, whether laboratory developed or commercial. In this multicenter study, we evaluated the Toxoplasma ELITe MGB (Elitech) commercial kit by comparison with three reference quantitative PCR assays (RAs) used routinely in three proficient laboratories of the French National Reference Center for Toxoplasmosis network, using Toxoplasma calibrated suspensions diluted to obtain a range of concentrations from 0.1 to 10,000 parasites/ml. These suspensions were extracted with either the DNA extraction kit (EXTRAblood; Elitech) recommended by the manufacturer or the QIAamp DNA minikit (Qiagen). The Toxoplasma ELITe MGB assay was also evaluated on a panel of 128 clinical samples, including 56 amniotic fluid samples, 55 placenta samples, and various other samples, of which 95 originated from patients with proven toxoplasmosis. The ELITe MGB assay amplified low-concentration replicates (<10 parasites/ml) of calibrated suspensions less frequently than the RAs of 2/3 laboratories. Additionally, the combination of EXTRAblood and Toxoplasma ELITe MGB yielded poorer sensitivity than the combination of QIAamp DNA minikit and ELITe MGB for low parasite concentrations (P < 0.001 for 1 parasite/ml). On clinical samples, the sensitivity and the specificity of the commercial assay were 89% and 100%, respectively. The sensitivity ranged from 79% (placenta samples) to 100% (amniotic fluid samples). Overall, this study shows that the Toxoplasma ELITe MGB assay is suitable for the diagnosis of toxoplasmosis from non-cell-rich or non-hemoglobin-rich samples and that the EXTRAblood kit is not optimal. PMID:28202794
Sparrow, Annie; Almilaji, Khaled; Tajaldin, Bachir; Teodoro, Nicholas; Langton, Paul
2016-01-01
Background Public health breakdown from the Syrian government's targeting of healthcare systems in politically unsympathetic areas has yielded a resurgence of infectious diseases. Suspected cholera recently reappeared but conflict-related constraints impede laboratory confirmation. Given the government's previous under-reporting of infectious outbreaks and the reliance of the WHO on government reporting, we sought to assess the reliability of current surveillance systems. Methods We compared weekly surveillance reports of waterborne diseases from the Syrian government's (WHO-associated) Early Warning and Response System (EWARS), based in Damascus, and the independent, non-governmental Early Warning and Response Network (EWARN) headquartered in Gaziantep, Turkey. We compared raw case rates by EWARS and EWARN and assessed the quality of reporting against the WHO benchmarks. Results We identified significant under-reporting and delays in the government's surveillance. On average, EWARS reports were published 24 days (range 12–61) after the reference week compared with 11 days (5–21) for EWARN. Average completeness for EWARS was 75% (55–84%), compared with 92% for EWARN (85–99%). Average timeliness for EWARS was 79% (51–100%), compared with 88% for EWARN (70–97%). EWARS made limited use of rapid diagnostic tests, and rates of collection of stool samples for laboratory cholera testing were well below reference levels. Conclusions In the context of the current Syrian war, the government's surveillance is inadequate due to lack of access to non-government held territory, an incentive to under-report the consequence of government attacks on health infrastructure, and an impractical insistence on laboratory confirmation. These findings should guide the WHO reform for surveillance in conflict zones. PMID:28588951
Evaluation of Toxoplasma ELITe MGB Real-Time PCR Assay for Diagnosis of Toxoplasmosis.
Robert-Gangneux, Florence; Brenier-Pinchart, Marie-Pierre; Yera, Hélène; Belaz, Sorya; Varlet-Marie, Emmanuelle; Bastien, Patrick
2017-05-01
Molecular diagnosis of congenital toxoplasmosis or disseminated toxoplasmosis is based mainly on PCR. The repeated DNA element rep529 has become the main DNA target used in most PCR methods, whether laboratory developed or commercial. In this multicenter study, we evaluated the Toxoplasma ELITe MGB (Elitech) commercial kit by comparison with three reference quantitative PCR assays (RAs) used routinely in three proficient laboratories of the French National Reference Center for Toxoplasmosis network, using Toxoplasma calibrated suspensions diluted to obtain a range of concentrations from 0.1 to 10,000 parasites/ml. These suspensions were extracted with either the DNA extraction kit (EXTRAblood; Elitech) recommended by the manufacturer or the QIAamp DNA minikit (Qiagen). The Toxoplasma ELITe MGB assay was also evaluated on a panel of 128 clinical samples, including 56 amniotic fluid samples, 55 placenta samples, and various other samples, of which 95 originated from patients with proven toxoplasmosis. The ELITe MGB assay amplified low-concentration replicates (<10 parasites/ml) of calibrated suspensions less frequently than the RAs of 2/3 laboratories. Additionally, the combination of EXTRAblood and Toxoplasma ELITe MGB yielded poorer sensitivity than the combination of QIAamp DNA minikit and ELITe MGB for low parasite concentrations ( P < 0.001 for 1 parasite/ml). On clinical samples, the sensitivity and the specificity of the commercial assay were 89% and 100%, respectively. The sensitivity ranged from 79% (placenta samples) to 100% (amniotic fluid samples). Overall, this study shows that the Toxoplasma ELITe MGB assay is suitable for the diagnosis of toxoplasmosis from non-cell-rich or non-hemoglobin-rich samples and that the EXTRAblood kit is not optimal. Copyright © 2017 American Society for Microbiology.
42 CFR 493.1264 - Standard: Parasitology.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Systems § 493.1264 Standard: Parasitology. (a) The laboratory must have available a reference collection... these references in the laboratory for appropriate comparison with diagnostic specimens. (b) The...
Dantas, B M; Dantas, A L A; Acar, M E D; Cardoso, J C S; Julião, L M Q C; Lima, M F; Taddei, M H T; Arine, D R; Alonso, T; Ramos, M A P; Fajgelj, A
2011-03-01
In recent years, Brazilian Nuclear Programme has been reviewed and updated by government authorities in face of the demand for energy supply and its associated environmental constraints. The immediate impact of new national programmes and projects in nuclear field is the increase in the number of exposed personnel and the consequent need for reliable dosimetry services in the country. Several Technical Documents related to internal dosimetry have been released by the International Atomic Energy Agency and International Commission on Radiological Protection. However, standard bioassay procedures and methodologies for bioassay data interpretation are still under discussion and, in some cases, both in routine and emergency internal monitoring, procedures can vary from one laboratory to another and responses may differ markedly among Dosimetry Laboratories. Thus, it may be difficult to interpret and use bioassay data generated from different laboratories of a network. The main goal of this work is to implement a National Network of Laboratories aimed to provide reliable internal monitoring services in Brazil. The establishment of harmonised in vivo and in vitro radioanalytical techniques, dose assessment methods and the implementation of the ISO/IEC 17025 requirements will result in the recognition of technical competence of the network.
Farrar, Jerry W.
1999-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for seven standard reference samples -- T-155 (trace constituents), M-148 (major constituents), N-59 (nutrient constituents), N-60 (nutrient constituents), P-31 (low ionic strength constituents), GWT-4 (ground-water trace constituents), and Hg- 27 (mercury) -- which were distributed in September 1998 to 162 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 136 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the seven reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the seven standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Long, H.K.; Farrar, J.W.
1994-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for eight standard reference samples--T-127 (trace constituents), M-128 (major constituents), N-40 (nutrients), N-41 (nutrients), P-21 (low ionic strength), Hg-17 (mercury), AMW-3 (acid mine water), and WW-1 (whole water)--that were distributed in October 1993 to 158 laboratories registered in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 145 of the laboratories were evaluated with respect to: overall laboratory performance and relative laboratory performance for each analyte in the eight reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the eight standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Long, H. Keith; Farrar, Jerry W.
1995-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for 7 standard reference samples--T-131 (trace constituents), T-133 (trace constituents), M-132 (major constituents), N-43 (nutrients), N-44 (nutrients), P-23 (low ionic strength), and Hg-19 (mercury). The samples were distributed in October 1994 to 131 laboratories registered in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 121 of the laboratories were evaluated with respect to: overall laboratory performance and relative laboratory performance for each analyte in the seven reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the seven standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Survey of point-of-care instrumentation, analysis, and quality assurance in veterinary practice.
Bell, Regan; Harr, Kendal; Rishniw, Mark; Pion, Paul
2014-06-01
While there have been ASVCP meeting discussions regarding quality assurance plans and lack thereof for in-clinic analyzers, there are little published data regarding in-clinic quality assurance and control practices. The purpose of this study was the identification of the common equipment used in hematologic, biochemical, urinalysis, and other testing, and assessment of quality control and assurance programs currently being performed in-clinic. All members of the Veterinary Information Network (VIN) were solicited to participate in an online survey between July and September 2007. In total, 452 complete or partial responses were received. Eighty-nine percent of respondents (361/404) said that veterinary technicians (unlicensed, licensed, and registered) performed the majority of analyses. Eighty-eight percent (366/417) of respondents performed some quality assurance on their laboratory equipment, most commonly on chemistry (91%, 324/357), and hematology (84%, 292/347) analyzers, and least commonly on fecal analyses (57%, 148/260) and ELISA assays (25%, 65/256). Ignorance of how to perform quality assurance was the most commonly stated reason (49%, 25/51) for lack of a quality assurance program. The majority of practices (316/374) utilized manufacturer-provided reference intervals without further adjustment or assessment. Roughly one-third of respondents (126/374) used reference intervals from textbooks, which is discouraged by ASVCP guidelines. This study found that the majority of respondents were not in compliance with ASVCP guidelines, illustrating the need for improved education of technical staff, veterinary students, and veterinarians regarding limitations of in-clinic laboratory equipment and the importance of regular quality control, maintenance, training, and reference interval development. © 2014 American Society for Veterinary Clinical Pathology and European Society for Veterinary Clinical Pathology.
Networking DEC and IBM computers
NASA Technical Reports Server (NTRS)
Mish, W. H.
1983-01-01
Local Area Networking of DEC and IBM computers within the structure of the ISO-OSI Seven Layer Reference Model at a raw signaling speed of 1 Mops or greater are discussed. After an introduction to the ISO-OSI Reference Model nd the IEEE-802 Draft Standard for Local Area Networks (LANs), there follows a detailed discussion and comparison of the products available from a variety of manufactures to perform this networking task. A summary of these products is presented in a table.
Future global SLR network evolution and its impact on the terrestrial reference frame
NASA Astrophysics Data System (ADS)
Kehm, Alexander; Bloßfeld, Mathis; Pavlis, Erricos C.; Seitz, Florian
2018-06-01
Satellite laser ranging (SLR) is an important technique that contributes to the determination of terrestrial geodetic reference frames, especially to the realization of the origin and the scale of global networks. One of the major limiting factors of SLR-derived reference frame realizations is the datum accuracy which significantly suffers from the current global SLR station distribution. In this paper, the impact of a potential future development of the SLR network on the estimated datum parameters is investigated. The current status of the SLR network is compared to a simulated potential future network featuring additional stations improving the global network geometry. In addition, possible technical advancements resulting in a higher amount of observations are taken into account as well. As a result, we find that the network improvement causes a decrease in the scatter of the network translation parameters of up to 24%, and up to 20% for the scale, whereas the technological improvement causes a reduction in the scatter of up to 27% for the translations and up to 49% for the scale. The Earth orientation parameters benefit by up to 15% from both effects.
Interlaboratory comparison of reference materials for nitrogen-isotope-ratio measurements
Böhlke, John Karl; Coplen, Tyler B.
1995-01-01
Aliquots of seven different reference materials were distributed for an interlaboratory comparison of stable nitrogen-isotope-ratio measurements. Results from 15 laboratories were compiled and evaluated selectively to yield provisional values of 515N for each material, i, with respect to atmospheric N2 (o1SN,7air). The 515N values reported by the different laboratories are correlated in such a way that some of the major discrepancies may be removed by normalization (/. e., by altering the length of the ô N scale for each laboratory by an amount defined by local measurements of reference materials with extreme values).
The world's microbiology laboratories can be a global microbial sensor network.
O'Brien, Thomas F; Stelling, John
2014-04-01
The microbes that infect us spread in global and local epidemics, and the resistance genes that block their treatment spread within and between them. All we can know about where they are to track and contain them comes from the only places that can see them, the world's microbiology laboratories, but most report each patient's microbe only to that patient's caregiver. Sensors, ranging from instruments to birdwatchers, are now being linked in electronic networks to monitor and interpret algorithmically in real-time ocean currents, atmospheric carbon, supply-chain inventory, bird migration, etc. To so link the world's microbiology laboratories as exquisite sensors in a truly lifesaving real-time network their data must be accessed and fully subtyped. Microbiology laboratories put individual reports into inaccessible paper or mutually incompatible electronic reporting systems, but those from more than 2,200 laboratories in more than 108 countries worldwide are now accessed and translated into compatible WHONET files. These increasingly web-based files could initiate a global microbial sensor network. Unused microbiology laboratory byproduct data, now from drug susceptibility and biochemical testing but increasingly from new technologies (genotyping, MALDI-TOF, etc.), can be reused to subtype microbes of each genus/species into sub-groupings that are discriminated and traced with greater sensitivity. Ongoing statistical delineation of subtypes from global sensor network data will improve detection of movement into any patient of a microbe or resistance gene from another patient, medical center or country. Growing data on clinical manifestations and global distributions of subtypes can automate comments for patient's reports, select microbes to genotype and alert responders.
Mee, Edward T.; Preston, Mark D.; Minor, Philip D.; Schepelmann, Silke; Huang, Xuening; Nguyen, Jenny; Wall, David; Hargrove, Stacey; Fu, Thomas; Xu, George; Li, Li; Cote, Colette; Delwart, Eric; Li, Linlin; Hewlett, Indira; Simonyan, Vahan; Ragupathy, Viswanath; Alin, Voskanian-Kordi; Mermod, Nicolas; Hill, Christiane; Ottenwälder, Birgit; Richter, Daniel C.; Tehrani, Arman; Jacqueline, Weber-Lehmann; Cassart, Jean-Pol; Letellier, Carine; Vandeputte, Olivier; Ruelle, Jean-Louis; Deyati, Avisek; La Neve, Fabio; Modena, Chiara; Mee, Edward; Schepelmann, Silke; Preston, Mark; Minor, Philip; Eloit, Marc; Muth, Erika; Lamamy, Arnaud; Jagorel, Florence; Cheval, Justine; Anscombe, Catherine; Misra, Raju; Wooldridge, David; Gharbia, Saheer; Rose, Graham; Ng, Siemon H.S.; Charlebois, Robert L.; Gisonni-Lex, Lucy; Mallet, Laurent; Dorange, Fabien; Chiu, Charles; Naccache, Samia; Kellam, Paul; van der Hoek, Lia; Cotten, Matt; Mitchell, Christine; Baier, Brian S.; Sun, Wenping; Malicki, Heather D.
2016-01-01
Background Unbiased deep sequencing offers the potential for improved adventitious virus screening in vaccines and biotherapeutics. Successful implementation of such assays will require appropriate control materials to confirm assay performance and sensitivity. Methods A common reference material containing 25 target viruses was produced and 16 laboratories were invited to process it using their preferred adventitious virus detection assay. Results Fifteen laboratories returned results, obtained using a wide range of wet-lab and informatics methods. Six of 25 target viruses were detected by all laboratories, with the remaining viruses detected by 4–14 laboratories. Six non-target viruses were detected by three or more laboratories. Conclusion The study demonstrated that a wide range of methods are currently used for adventitious virus detection screening in biological products by deep sequencing and that they can yield significantly different results. This underscores the need for common reference materials to ensure satisfactory assay performance and enable comparisons between laboratories. PMID:26709640
IT behind a platform for Translational Cancer Research - concept and objectives.
Steffens, Michael; Husmann, Gabriele; Koca, Mithat; Lablans, Martin; Komor, Martina; Zeissig, Sylke; Emrich, Katharina; Brandts, Christian; Serve, Hubert; Blettner, Maria; Uckert, Frank
2012-01-01
The German Consortium for Translational Cancer Research (DKTK) and the Rhine-Main Translational Cancer Research Network (RM-TCRN) are designed to exploit large population cohorts of cancer patients for the purpose of bio-banking, clinical trials, and clinical cancer registration. Hence, the success of these platforms is heavily dependent on the close interlinking of clinical data from cancer patients, information from study registries, and data from bio-banking systems of different laboratories and scientific institutions. This article referring to the poster discusses the main challenges of the platforms from an information technology point of view, legal and data security issues, and outlines an integrative IT-concept concerning a decentralized, distributed search approach where data management and search is in compliance with existing legislative rules.
NASA Astrophysics Data System (ADS)
Martínez, Fredy; Martínez, Fernando; Jacinto, Edwar
2017-02-01
In this paper we propose an on-line motion planning strategy for autonomous robots in dynamic and locally observable environments. In this approach, we first visually identify geometric shapes in the environment by filtering images. Then, an ART-2 network is used to establish the similarity between patterns. The proposed algorithm allows that a robot establish its relative location in the environment, and define its navigation path based on images of the environment and its similarity to reference images. This is an efficient and minimalist method that uses the similarity of landmark view patterns to navigate to the desired destination. Laboratory tests on real prototypes demonstrate the performance of the algorithm.
NASA Astrophysics Data System (ADS)
Kirst, Christoph
It is astonishing how the sub-parts of a brain co-act to produce coherent behavior. What are mechanism that coordinate information processing and communication and how can those be changed flexibly in order to cope with variable contexts? Here we show that when information is encoded in the deviations around a collective dynamical reference state of a recurrent network the propagation of these fluctuations is strongly dependent on precisely this underlying reference. Information here 'surfs' on top of the collective dynamics and switching between states enables fast and flexible rerouting of information. This in turn affects local processing and consequently changes in the global reference dynamics that re-regulate the distribution of information. This provides a generic mechanism for self-organized information processing as we demonstrate with an oscillatory Hopfield network that performs contextual pattern recognition. Deep neural networks have proven to be very successful recently. Here we show that generating information channels via collective reference dynamics can effectively compress a deep multi-layer architecture into a single layer making this mechanism a promising candidate for the organization of information processing in biological neuronal networks.
Chemical mutagenesis in laboratory mammals. A bibliography on the effects of chemicals on germ cells
DOE Office of Scientific and Technical Information (OSTI.GOV)
Von Halle, E.S.
1973-09-01
A list of references is presented on chemical mutagenesis in laboratory mammals. The references relate primarily to chemical effects on germ cells. Only references to the use of chemicals or chemicals and radiation are included. The publication includes a citation index, agent index, chemical abstracts registry number index, organism index, KWIC index, author index, and first author index. (ERB)
Global Measles and Rubella Laboratory Network Support for Elimination Goals, 2010-2015.
Mulders, Mick N; Rota, Paul A; Icenogle, Joseph P; Brown, Kevin E; Takeda, Makoto; Rey, Gloria J; Ben Mamou, Myriam C; Dosseh, Annick R G A; Byabamazima, Charles R; Ahmed, Hinda J; Pattamadilok, Sirima; Zhang, Yan; Gacic-Dobo, Marta; Strebel, Peter M; Goodson, James L
2016-05-06
In 2012, the World Health Assembly endorsed the Global Vaccine Action Plan (GVAP)* with the objective to eliminate measles and rubella in five World Health Organization (WHO) regions by 2020. In September 2013, countries in all six WHO regions had established measles elimination goals, and additional goals for elimination of rubella and congenital rubella syndrome were established in three regions (1). Capacity for surveillance, including laboratory confirmation, is fundamental to monitoring and verifying elimination. The 2012-2020 Global Measles and Rubella Strategic Plan of the Measles and Rubella Initiative(†) calls for effective case-based surveillance with laboratory testing for case confirmation (2). In 2000, the WHO Global Measles and Rubella Laboratory Network (GMRLN) was established to provide high quality laboratory support for surveillance (3). The GMRLN is the largest globally coordinated laboratory network, with 703 laboratories supporting surveillance in 191 countries. During 2010-2015, 742,187 serum specimens were tested, and 27,832 viral sequences were reported globally. Expansion of the capacity of the GMRLN will support measles and rubella elimination efforts as well as surveillance for other vaccine-preventable diseases (VPDs), including rotavirus, and for emerging pathogens of public health concern.
How to maintain blood supply during computer network breakdown: a manual backup system.
Zeiler, T; Slonka, J; Bürgi, H R; Kretschmer, V
2000-12-01
Electronic data management systems using computer network systems and client/server architecture are increasingly used in laboratories and transfusion services. Severe problems arise if there is no network access to the database server and critical functions are not available. We describe a manual backup system (MBS) developed to maintain the delivery of blood products to patients in a hospital transfusion service in case of a computer network breakdown. All data are kept on a central SQL database connected to peripheral workstations in a local area network (LAN). Request entry from wards is performed via machine-readable request forms containing self-adhesive specimen labels with barcodes for test tubes. Data entry occurs on-line by bidirectional automated systems or off-line manually. One of the workstations in the laboratory contains a second SQL database which is frequently and incrementally updated. This workstation is run as a stand-alone, read-only database if the central SQL database is not available. In case of a network breakdown, the time-graded MBS is launched. Patient data, requesting ward and ordered tests/requests, are photocopied through a template from the request forms on special MBS worksheets serving as laboratory journal for manual processing and result report (a copy is left in the laboratory). As soon as the network is running again the data from the off-line period are entered into the primary SQL server. The MBS was successfully used at several occasions. The documentation of a 90-min breakdown period is presented in detail. Additional work resulted from the copy work and the belated manual data entry after restoration of the system. There was no delay in issue of blood products or result reporting. The backup system described has been proven to be simple, quick and safe to maintain urgent blood supply and distribution of laboratory results in case of unexpected network breakdown.
Computation of Estonian CORS data using Bernese 5.2 and Gipsy 6.4 softwares
NASA Astrophysics Data System (ADS)
Kollo, Karin; Kall, Tarmo; Liibusk, Aive
2017-04-01
GNSS permanent station network in Estonia (ESTREF) was established already in 2007. In 2014-15 extensive reconstruction of ESTREF was carried out, including the establishment of 18 new stations, change of the hardware in CORS stations as well as establishing GNSS-RTK service for the whole Estonia. For GNSS-RTK service one needs precise coordinates in well-defined reference frame, i.e., ETRS89. For long time stability of stations and time-series analysis the re-processing of Estonian CORS data is ongoing. We re-process data from 2007 until 2015 with program Bernese GNSS 5.2 (Dach, 2015). For the set of ESTREF stations established in 2007, we perform as well computations with GIPSY 6.4 software (Ries et al., 2015). In the computations daily GPS-only solution was used. For precise orbits, final products from CODE (CODE analysis centre at the Astronomical Institute of the University of Bern) and JPL (Jet Propulsion Laboratory) for Bernese and GIPSY solutions were used, respectively. The cut-off angle was set to 10 degrees in order to avoid near-field multipath influence. In GIPSY, precise point positioning method with fixing ambiguities was used. Bernese calculations were performed based on double difference processing. Antenna phase centers were modelled based on igs08.atx and epnc_08.atx files. Vienna mapping function was used for mapping tropospheric delays. For the GIPSY solution, the higher order ionospheric term was modelled based on IRI-2012b model. For the Bernese solution higher order ionospheric term was neglected. FES2004 ocean tide loading model was used for the both computation strategies. As a result, two solutions using different scientific GNSS computation programs were obtained. The results from Bernese and GIPSY solutions were compared, using station repeatability values, RMS and coordinate differences. KEYWORDS: GNSS reference station network, Bernese GNSS 5.2, Gipsy 6.4, Estonia. References: Dach, R., S. Lutz, P. Walser, P. Fridez (Eds); 2015: Bernese GNSS Software Version 5.2. User manual, Astronomical Institute, Universtiy of Bern, Bern Open Publishing. DOI: 10.7892/boris.72297; ISBN: 978-3-906813-05-9. Paul Ries, Willy Bertiger, Shailen, Shailen Desai, & Kevin Miller. (2015). GIPSY 6.4 Release Notes. Jet Propulsion Laboratory, California Institute of Technology. Retrieved from https://gipsy-oasis.jpl.nasa.gov/docs/index.php
Louisiana coastal GIS network: Graphical user interface for access to spatial data
Hiland, Matteson; McBride, Randolph A.; Davis, Donald; Braud, Dewitt; Streiffer, Henry; Jones, Farrell; Lewis, Anthony; Williams, S.
1991-01-01
Louisiana's coastal wetlands support a large percentage of the nation's seafood and fur industries, vast deposits of oil and natural gas, habitat for thousands of species of plants and animals, winter nesting grounds and migratory paths for numerous waterfowl, and many recreational resources enjoyed by residents and tourists. Louisiana's wetlands also have the highest rates of coastal erosion and wetland loss in the nation. While numerous studies across many disciplines have been conducted on both local and regional scales, no complete inventory exists for this information. The Louisiana Coastal Geographic Information System Network (LCGISN) is currently being developed to facilitate access to existing data for coastal zone planners, managers, and researchers. The Louisiana Geological Survey (LGS), in cooperation with the LSU Department of Geography and Anthropology, the Computer Aided Design and Geographic Information Systems Research Laboratory (CADGIS), and others, is pursuing this project under the terms of a cooperative agreement with the U.S. Geological Survey. LCGISN is an automated system for searching and retrieving geographic, cartographic, and bibliographic data. By linking original programming with an existing GIS software package and an industry standard relational database management system, LCGISN will provide the capability for users to search for data references by interactively defining the area of interest on a displayed map/image reference background. Several agencies will be networked to provide easy access to a wide variety of information. LCGISN, with its headquarters at LGS, will serve as the central node on the network, providing data format conversions, projection and datum transformations, and storage of several of the most commonly used data sets. Thematic mapper data, USGS 7.5-minute quadrangle map boundaries, political and legal boundaries, major transportation routes, and other digital data will provide a base map to aid the user in selecting the exact area of interest. Then, the user will set search criteria by proceeding through a series of menu-driven options. The system will then return any or all of the following: a list of digital maps or imagery that can be displayed immediately and visually overlayed, a list of maps/remotely sensed data and information on their availability, and a list of bibliographic references concerning the area and subject defined.
[Laboratory accreditation and proficiency testing].
Kuwa, Katsuhiko
2003-05-01
ISO/TC 212 covering clinical laboratory testing and in vitro diagnostic test systems will issue the international standard for medical laboratory quality and competence requirements, ISO 15189. This standard is based on the ISO/IEC 17025, general requirements for competence of testing and calibration laboratories and ISO 9001, quality management systems-requirements. Clinical laboratory services are essential to patient care and therefore should be available to meet the needs of all patients and clinical personnel responsible for human health care. If a laboratory seeks accreditation, it should select an accreditation body that operates according to this international standard and in a manner which takes into account the particular requirements of clinical laboratories. Proficiency testing should be available to evaluate the calibration laboratories and reference measurement laboratories in clinical medicine. Reference measurement procedures should be of precise and the analytical principle of measurement applied should ensure reliability. We should be prepared to establish a quality management system and proficiency testing in clinical laboratories.
Wright, Laura L; Turton, Jane F; Livermore, David M; Hopkins, Katie L; Woodford, Neil
2015-01-01
Carbapenem-resistant isolates of Pseudomonas aeruginosa producing metallo-β-lactamases (MBLs) are increasingly reported worldwide and often belong to particular 'high-risk clones'. This study aimed to characterize a comprehensive collection of MBL-producing P. aeruginosa isolates referred to the UK national reference laboratory from multiple UK laboratories over a 10 year period. Isolates were referred to the UK national reference laboratory between 2003 and 2012 for investigation of resistance mechanisms and/or outbreaks. MBL genes were detected by PCR. Typing was carried out by nine-locus variable-number tandem repeat (VNTR) analysis and MLST. MBL-producing P. aeruginosa isolates were referred from 267 source patients and 89 UK laboratories. The most common isolation sites were urine (24%), respiratory (18%), wounds (17%) and blood (13%). VIM-type MBLs predominated (91% of all MBLs found), but a few IMP- and NDM-type enzymes were also identified. Diverse VNTR types were seen, but 86% of isolates belonged to six major complexes. MLST of representative isolates from each complex showed that they corresponded to STs 111, 233, 235, 357, 654 and 773, respectively. Isolates belonging to these complexes were received from between 9 and 25 UK referring laboratories each. The incidence of MBL-producing P. aeruginosa is increasing in the UK. The majority of these isolates belong to several 'high-risk clones', which have been previously reported internationally as host clones of MBLs. © Crown copyright 2014.
Multicomponent blood lipid analysis by means of near infrared spectroscopy, in geese.
Bazar, George; Eles, Viktoria; Kovacs, Zoltan; Romvari, Robert; Szabo, Andras
2016-08-01
This study provides accurate near infrared (NIR) spectroscopic models on some laboratory determined clinicochemical parameters (i.e. total lipid (5.57±1.95 g/l), triglyceride (2.59±1.36 mmol/l), total cholesterol (3.81±0.68 mmol/l), high density lipoprotein (HDL) cholesterol (2.45±0.58 mmol/l)) of blood serum samples of fattened geese. To increase the performance of multivariate chemometrics, samples significantly deviating from the regression models implying laboratory error were excluded from the final calibration datasets. Reference data of excluded samples having outlier spectra in principal component analysis were not marked as false. Samples deviating from the regression models but having non outlier spectra in PCA were identified as having false reference constituent values. Based on the NIR selection methods, 5% of the reference measurement data were rated as doubtful. The achieved models reached R(2) of 0.864, 0.966, 0.850, 0.793, and RMSE of 0.639 g/l, 0.232 mmol/l, 0.210 mmol/l, 0.241 mmol/l for total lipid, triglyceride, total cholesterol and HDL cholesterol, respectively, during independent validation. Classical analytical techniques focus on single constituents and often require chemicals, time-consuming measurements, and experienced technicians. NIR technique provides a quick, cost effective, non-hazardous alternative method for analysis of several constituents based on one single spectrum of each sample, and it also offers the possibility for looking at the laboratory reference data critically. Evaluation of reference data to identify and exclude falsely analyzed samples can provide warning feedback to the reference laboratory, especially in the case of analyses where laboratory methods are not perfectly suited to the subjected material and there is an increased chance of laboratory error. Copyright © 2016 Elsevier B.V. All rights reserved.
Li, Meng-Jiao; Ge, Miao; Wang, Cong-Xia; Cen, Min-Yi; Jiang, Ji-Lin; He, Jin-Wei; Lin, Qian-Yi; Liu, Xin
2016-08-20
To analyze the relationship between the reference values of fibrinogen (FIB) in healthy Chinese adults and geographical factors to provide scientific evidences for establishing the uniform standard. The reference values of FIB of 10701 Chinese healthy adults from 103 cities were collected to investigate their relationship with 18 geographical factors including spatial index, terrain index, climate index, and soil index. Geographical factors that significantly correlated with the reference values were selected for constructing the BP neural network model. The spatial distribution map of the reference value of FIB of healthy Chinese adults was fitted by disjunctive kriging interpolation. We used the 5-layer neural network and selected 2000 times of training covering 11 hidden layers to build the simulation rule for simulating the relationship between FIB and geographical environmental factors using the MATLAB software. s The reference value of FIB in healthy Chinese adults was significantly correlated with the latitude, sunshine duration, annual average temperature, annual average relative humidity, annual precipitation, annual range of air temperature, average annual soil gravel content, and soil cation exchange capacity (silt). The artificial neural networks were created to analyze the simulation of the selected indicators of geographical factors. The spatial distribution map of the reference values of FIB in healthy Chinese adults showed a distribution pattern that FIB levels were higher in the South and lower in the North, and higher in the East and lower in the West. When the geographical factors of a certain area are known, the reference values of FIB in healthy Chinese adults can be obtained by establishing the neural network mode or plotting the spatial distribution map.
Szymanowicz, A; Watine, J
2010-12-01
In this paper are presented some useful web sites to find updated reference tables concerning the recommendations of professional practices in laboratory medicine. The knowledge of these reference tables can allow the biologist to develop its role of advice to the clinicians. It can also help him to assure a relevant interpretation of the laboratory results and to value the interest for the patient.
Southern, Danielle A; Roberts, Barbara; Edwards, Alun; Dean, Stafford; Norton, Peter; Svenson, Lawrence W; Larsen, Erik; Sargious, Peter; Lau, David C W; Ghali, William A
2010-01-01
This study assessed the validity of a widely-accepted administrative data surveillance methodology for identifying individuals with diabetes relative to three laboratory data reference standard definitions for diabetes. We used a combination of linked regional data (hospital discharge abstracts and physician data) and laboratory data to test the validity of administrative data surveillance definitions for diabetes relative to a laboratory data reference standard. The administrative discharge data methodology includes two definitions for diabetes: a strict administrative data definition of one hospitalization code or two physician claims indicating diabetes; and a more liberal definition of one hospitalization code or a single physician claim. The laboratory data, meanwhile, produced three reference standard definitions based on glucose levels +/- HbA1c levels. Sensitivities ranged from 68.4% to 86.9% for the administrative data definitions tested relative to the three laboratory data reference standards. Sensitivities were higher for the more liberal administrative data definition. Positive predictive values (PPV), meanwhile, ranged from 53.0% to 88.3%, with the liberal administrative data definition producing lower PPVs. These findings demonstrate the trade-offs of sensitivity and PPV for selecting diabetes surveillance definitions. Centralized laboratory data may be of value to future surveillance initiatives that use combined data sources to optimize case detection.
Networked differential GPS system
NASA Technical Reports Server (NTRS)
Sheynblat, Leonid (Inventor); Kalafus, Rudolph M. (Inventor); Loomis, Peter V. W. (Inventor); Mueller, K. Tysen (Inventor)
1994-01-01
An embodiment of the present invention relates to a worldwide network of differential GPS reference stations (NDGPS) that continually track the entire GPS satellite constellation and provide interpolations of reference station corrections tailored for particular user locations between the reference stations Each reference station takes real-time ionospheric measurements with codeless cross-correlating dual-frequency carrier GPS receivers and computes real-time orbit ephemerides independently. An absolute pseudorange correction (PRC) is defined for each satellite as a function of a particular user's location. A map of the function is constructed, with iso-PRC contours. The network measures the PRCs at a few points, so-called reference stations and constructs an iso-PRC map for each satellite. Corrections are interpolated for each user's site on a subscription basis. The data bandwidths are kept to a minimum by transmitting information that cannot be obtained directly by the user and by updating information by classes and according to how quickly each class of data goes stale given the realities of the GPS system. Sub-decimeter-level kinematic accuracy over a given area is accomplished by establishing a mini-fiducial network.
Access to laboratory testing: the impact of managed care in the Pacific Northwest.
LaBeau, K M; Simon, M; Steindel, S J
1999-01-01
Patient access to health-care services has become an important issue owing to the growth of managed care organizations and the number of patients enrolled. To better understand the current issues related to access to laboratory testing, with a particular focus on the impact of managed care, we gathered information from a network of clinical laboratories in the Pacific Northwest. Two questionnaires were sent to the 257 Laboratory Medicine Sentinel Monitoring Network participants in November 1995 and March 1996 to investigate trends in the availability and utilization of laboratory testing services and changes in onsite testing menus. Although laboratories reported that managed care was a factor in their decisions about laboratory practices, testing decisions were more likely made for business reasons, based on medical practice changes and marketplace influences not associated with managed care.
Coplen, Tyler B.
2010-01-01
Measurement of the same isotopically homogeneous sample by any laboratory worldwide should yield the same isotopic composition within analytical uncertainty. International distribution of light element isotopic reference materials by the International Atomic Energy Agency and the U.S. National Institute of Standards and Technology enable laboratories to achieve this goal.
User's manual for a material transport code on the Octopus Computer Network
DOE Office of Scientific and Technical Information (OSTI.GOV)
Naymik, T.G.; Mendez, G.D.
1978-09-15
A code to simulate material transport through porous media was developed at Oak Ridge National Laboratory. This code has been modified and adapted for use at Lawrence Livermore Laboratory. This manual, in conjunction with report ORNL-4928, explains the input, output, and execution of the code on the Octopus Computer Network.
A Network Steganography Lab on Detecting TCP/IP Covert Channels
ERIC Educational Resources Information Center
Zseby, Tanja; Vázquez, Félix Iglesias; Bernhardt, Valentin; Frkat, Davor; Annessi, Robert
2016-01-01
This paper presents a network security laboratory to teach data analysis for detecting TCP/IP covert channels. The laboratory is mainly designed for students of electrical engineering, but is open to students of other technical disciplines with similar background. Covert channels provide a method for leaking data from protected systems, which is a…
Comparing ImmunoCard with two EIA assays for Clostridium difficile toxins.
Chan, Edward L; Seales, Diane; Drum, Hong
2009-01-01
To compare three Clostridium difficile EIA kits for the detection of C. difficile toxins from clinical specimens. A total of 287 fresh and stored stool specimens were tested using all three assays. Stools with discrepant results were sent to a reference laboratory for tissue cytotoxin assay. Trinity Medical Center, a community hospital with network hospitals. Patients with diarrhea submitted stools for detection of C. difficile toxins. Of the 287 stool specimens, 116 were positive and 171 negative for C. difficile toxins. The sensitivity, specificity, and positive and negative predictive values of Meridian EIA assay were 99.1, 97.7, 96.6, and 99.4%; ImmunoCard were 100, 98.2, 97.5, and 100%; BioStar OIA assay were 94, 98.8, 98.2, and 96% respectively. ImmunoCardprovides the best sensitivity (100%) for C. difficile toxins A and B detection. The BioStar OIA rapid test missed seven positive stool specimens possibly due to failure to detect toxin B. ImmunoCard has slightly higher predictive values, shorter turnaround time and greater convenience compared to the Meridian EIA Assay. ImmunoCard may be cost effective not only in smaller laboratories, but also in high volume laboratories, when used on a STAT basis or single request.
Masanza, Monica Musenero; Nqobile, Ndlovu; Mukanga, David; Gitta, Sheba Nakacubo
2010-12-03
Laboratory is one of the core capacities that countries must develop for the implementation of the International Health Regulations (IHR[2005]) since laboratory services play a major role in all the key processes of detection, assessment, response, notification, and monitoring of events. While developed countries easily adapt their well-organized routine laboratory services, resource-limited countries need considerable capacity building as many gaps still exist. In this paper, we discuss some of the efforts made by the African Field Epidemiology Network (AFENET) in supporting laboratory capacity development in the Africa region. The efforts range from promoting graduate level training programs to building advanced technical, managerial and leadership skills to in-service short course training for peripheral laboratory staff. A number of specific projects focus on external quality assurance, basic laboratory information systems, strengthening laboratory management towards accreditation, equipment calibration, harmonization of training materials, networking and provision of pre-packaged laboratory kits to support outbreak investigation. Available evidence indicates a positive effect of these efforts on laboratory capacity in the region. However, many opportunities exist, especially to support the roll-out of these projects as well as attending to some additional critical areas such as biosafety and biosecuity. We conclude that AFENET's approach of strengthening national and sub-national systems provide a model that could be adopted in resource-limited settings such as sub-Saharan Africa.
DNA-Based Methods in the Immunohematology Reference Laboratory
Denomme, Gregory A
2010-01-01
Although hemagglutination serves the immunohematology reference laboratory well, when used alone, it has limited capability to resolve complex problems. This overview discusses how molecular approaches can be used in the immunohematology reference laboratory. In order to apply molecular approaches to immunohematology, knowledge of genes, DNA-based methods, and the molecular bases of blood groups are required. When applied correctly, DNA-based methods can predict blood groups to resolve ABO/Rh discrepancies, identify variant alleles, and screen donors for antigen-negative units. DNA-based testing in immunohematology is a valuable tool used to resolve blood group incompatibilities and to support patients in their transfusion needs. PMID:21257350
Benschop, Corina C G; Connolly, Edward; Ansell, Ricky; Kokshoorn, Bas
2017-01-01
The interpretation of complex DNA profiles may differ between laboratories and reporting officers, which can lead to discrepancies in the final reports. In this study, we assessed the intra and inter laboratory variation in DNA mixture interpretation for three European ISO17025-accredited laboratories. To this aim, 26 reporting officers analyzed five sets of DNA profiles. Three main aspects were considered: 1) whether the mixed DNA profiles met the criteria for comparison to a reference profile, 2) the actual result of the comparison between references and DNA profiling data and 3) whether the weight of the DNA evidence could be assessed. Similarity in answers depended mostly on the complexity of the tasks. This study showed less variation within laboratories than between laboratories which could be the result of differences between internal laboratory guidelines and methods and tools available. Results show the profile types for which the three laboratories report differently, which informs indirectly on the complexity threshold the laboratories employ. Largest differences between laboratories were caused by the methods available to assess the weight of the DNA evidence. This exercise aids in training forensic scientists, refining laboratory guidelines and explaining differences between laboratories in court. Undertaking more collaborative exercises in future may stimulate dialog and consensus regarding interpretation. For training purposes, DNA profiles of the mixed stains and questioned references are made available. Copyright © 2016 The Chartered Society of Forensic Sciences. Published by Elsevier Ireland Ltd. All rights reserved.
GNSS RTK-networks: The significance and issues to realize a recent reference coordinate system
NASA Astrophysics Data System (ADS)
Umnig, Elke; Möller, Gregor; Weber, Robert
2014-05-01
The upcoming release of the new global reference frame ITRF2013 will provide high accurate reference station positions and station velocities at the mm- and mm/year level, respectively. ITRF users benefit from this development in various ways. For example, this new frame allows for embedding high accurate GNSS baseline observations to an underlying reference of at least the same accuracy. Another advantage is that the IGS products are fully consistent with this frame and therefore all GNSS based zero-difference positioning results (Precise Point Positioning (PPP)) will be aligned to the ITRF2013. Unfortunately the transistion to a new frame (or just to a new epoch) implies also issues in particular for providers and users of real time positioning services. Thus providers have to perform arrangements, such as the readjustment of the reference station coordinates and the update of the transformation parameters from the homogenous GNSS coordinate frame into the national datum. Finally providers have to inform their clients appropriately about these changes and significant adjustments. Furthermore the aspect of the continental reference frame has to be considered: In Europe the use of the continental reference system/reference frame ETRS89/ETRF2000 is, due to cross-national guidelines, recommend by most national mapping authorities. Subsequently GNSS post-processing applications are degraded by the concurrent use of the reference systems and reference frames, to which terrestrial site coordinates and satellite coordinates are aligned. In this presentation we highlight all significant steps and hurdles which have to be jumped over when introducing a new reference frame from point of view of a typical regional RTK-reference station network provider. This network is located in Austria and parts of the neighbouring countries and consists of about 40 reference stations. Moreover, we discuss the significance of permanently monitoring the stability of the reference network sites and the determination of station velocities/rates for geodynamical investigations.
Adult Hematology and Clinical Chemistry Laboratory Reference Ranges in a Zimbabwean Population.
Samaneka, Wadzanai P; Mandozana, Gibson; Tinago, Willard; Nhando, Nehemiah; Mgodi, Nyaradzo M; Bwakura-Dangarembizi, Mutsawashe F; Munjoma, Marshall W; Gomo, Zvenyika A R; Chirenje, Zvavahera M; Hakim, James G
2016-01-01
Laboratory reference ranges used for clinical care and clinical trials in various laboratories in Zimbabwe were derived from textbooks and research studies conducted more than ten years ago. Periodic verification of these ranges is essential to track changes over time. The purpose of this study was to establish hematology and chemistry laboratory reference ranges using more rigorous methods. A community-based cross-sectional study was carried out in Harare, Chitungwiza, and Mutoko. A multistage sampling technique was used. Samples were transported from the field for analysis at the ISO15189 certified University of Zimbabwe-University of California San Francisco Central Research Laboratory. Hematology and clinical chemistry reference ranges lower and upper reference limits were estimated at the 2.5th and 97.5th percentiles respectively. A total of 769 adults (54% males) aged 18 to 55 years were included in the analysis. Median age was 28 [IQR: 23-35] years. Males had significantly higher red cell counts, hemoglobin, hematocrit, and mean corpuscular hemoglobin compared to females. Females had higher white cell counts, platelets, absolute neutrophil counts, and absolute lymphocyte counts compared to males. There were no gender differences in eosinophils, monocytes, and absolute basophil count. Males had significantly higher levels of urea, sodium, potassium, calcium, creatinine, amylase, total protein, albumin and liver enzymes levels compared to females. Females had higher cholesterol and lipase compared with males. There are notable differences in the white cell counts, neutrophils, cholesterol, and creatinine kinase when compared with the currently used reference ranges. Data from this study provides new country specific reference ranges which should be immediately adopted for routine clinical care and accurate monitoring of adverse events in research studies.
Higgins, Victoria; Truong, Dorothy; Woroch, Amy; Chan, Man Khun; Tahmasebi, Houman; Adeli, Khosrow
2018-03-01
Evidence-based reference intervals (RIs) are essential to accurately interpret pediatric laboratory test results. To fill gaps in pediatric RIs, the Canadian Laboratory Initiative on Pediatric Reference Intervals (CALIPER) project developed an age- and sex-specific pediatric RI database based on healthy pediatric subjects. Originally established for Abbott ARCHITECT assays, CALIPER RIs were transferred to assays on Beckman, Roche, Siemens, and Ortho analytical platforms. This study provides transferred reference intervals for 29 biochemical assays for the Ortho VITROS 5600 Chemistry System (Ortho). Based on Clinical Laboratory Standards Institute (CLSI) guidelines, a method comparison analysis was performed by measuring approximately 200 patient serum samples using Abbott and Ortho assays. The equation of the line of best fit was calculated and the appropriateness of the linear model was assessed. This equation was used to transfer RIs from Abbott to Ortho assays. Transferred RIs were verified using 84 healthy pediatric serum samples from the CALIPER cohort. RIs for most chemistry analytes successfully transferred from Abbott to Ortho assays. Calcium and CO 2 did not meet statistical criteria for transference (r 2 <0.70). Of the 32 transferred reference intervals, 29 successfully verified with approximately 90% of results from reference samples falling within transferred confidence limits. Transferred RIs for total bilirubin, magnesium, and LDH did not meet verification criteria and are not reported. This study broadens the utility of the CALIPER pediatric RI database to laboratories using Ortho VITROS 5600 biochemical assays. Clinical laboratories should verify CALIPER reference intervals for their specific analytical platform and local population as recommended by CLSI. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Performance of the Colorado wind-profiling network, part 1.5A
NASA Technical Reports Server (NTRS)
Strauch, R. G.; Earnshaw, K. B.; Merritt, D. A.; Moran, K. P.; Vandekamp, D. W.
1984-01-01
The Wave Propagation Laboratory (WPL) has operated a network of radar wind Profilers in Colorado for about 1 year. The network consists of four VHF (50-MHz) radars and a UHF (915-MHz) radar. The Platteville VHF radar was developed by the Aeronomy Laboratory (AL) and has been operated jointly by WPL and AL for several years. The other radars were installed between February and May 1983. Experiences with these radars and some general aspects of tropospheric wind measurements with Doppler radar are discussed.
See, Randolph B.; Schroder, LeRoy J.; Willoughby, Timothy C.
1988-01-01
During 1986, the U.S. Geological Survey operated three programs to provide external quality-assurance monitoring of the National Atmospheric Deposition Program and National Trends Network. An intersite-comparison program was used to assess the accuracy of onsite pH and specific-conductance determinations at quarterly intervals. The blind-audit program was used to assess the effect of routine sample handling on the precision and bias of program and network wet-deposition data. Analytical results from four laboratories, which routinely analyze wet-deposition samples, were examined to determine if differences existed between laboratory analytical results and to provide estimates of the analytical precision of each laboratory. An average of 78 and 89 percent of the site operators participating in the intersite-comparison met the network goals for pH and specific conductance. A comparison of analytical values versus actual values for samples submitted as part of the blind-audit program indicated that analytical values were slightly but significantly (a = 0.01) larger than actual values for pH, magnesium, sodium, and sulfate; analytical values for specific conductance were slightly less than actual values. The decreased precision in the analyses of blind-audit samples when compared to interlaboratory studies indicates that a large amount of uncertainty in network deposition data may be a result of routine field operations. The results of the interlaboratory comparison study indicated that the magnitude of the difference between laboratory analyses was small for all analytes. Analyses of deionized, distilled water blanks by participating laboratories indicated that the laboratories had difficulty measuring analyte concentrations near their reported detection limits. (USGS)
46 CFR 164.013-2 - Incorporation by reference.
Code of Federal Regulations, 2014 CFR
2014-10-01
.... All approved material incorporated by reference may be inspected at the National Archives and Records... Fire Safety Division, U.S. Coast Guard Stop 7509, 2703 Martin Luther King Jr. Avenue SE., Washington...: Underwriters Laboratories (UL) Underwriters Laboratories, Inc., P.O. Box 13995, Research Triangle Park, NC...
46 CFR 164.013-2 - Incorporation by reference.
Code of Federal Regulations, 2013 CFR
2013-10-01
.... All approved material incorporated by reference may be inspected at the National Archives and Records... Fire Safety Division, U.S. Coast Guard Stop 7509, 2703 Martin Luther King Jr. Avenue SE., Washington...: Underwriters Laboratories (UL) Underwriters Laboratories, Inc., P.O. Box 13995, Research Triangle Park, NC...
Superfund Contract Laboratory Program
The Contract Laboratory Program (CLP) is a national network of EPA personnel, commercial laboratories, and support contractors whose primary mission is to provide data of known and documented quality to the Superfund program.
Juhel-Gaugain, Murielle; Fourmond, Marie-Pierre; Delepine, Bernard; Laurentie, Michel; Brigitte, Roudaut; Sanders, Pascal
2005-03-01
Two interlaboratory studies were organized in 2002-2003 in order to check the proficiency of laboratories in confirming the presence of sulfonamide residues in muscle and milk. These studies involved 25 EU National Reference Laboratories (NRLs) from 21 different European Countries in charge of statutory monitoring of antimicrobial residues in food of animal origin at a national level. The study was conducted according to international and national guidelines by the Community Reference Laboratory (CRL) in charge of antimicrobial substances. Four different test matrices of sheep muscle and four different test matrices of bovine milk containing different sulfonamide substances were prepared and sent to the participants. Each participant was asked to use his own routine confirmatory method and to analyse each sample in triplicate within a period of about six weeks during which the stability of the materials was checked by the organizer. The sulfonamide content of each material was determined by calculating the robust means of all the results and the deviation of the results from the assigned values was assessed by calculating Z-scores. Overall, results were satisfactory, particularly considering that it was the first proficiency test dealing with sulfonamides organised by the Community Reference Laboratory.
The Global Geodetic Observing System: Space Geodesy Networks for the Future
NASA Technical Reports Server (NTRS)
Pearlman, Michael; Pavlis, Erricos; Ma, Chopo; Altamini, Zuheir; Noll, Carey; Stowers, David
2011-01-01
Ground-based networks of co-located space geodetic techniques (VLBI, SLR, GNSS. and DORIS) are the basis for the development and maintenance of the International Terrestrial Reference frame (ITRF), which is our metric of reference for measurements of global change, The Global Geodetic Observing System (GGOS) of the International Association of Geodesy (IAG) has established a task to develop a strategy to design, integrate and maintain the fundamental geodetic network and supporting infrastructure in a sustainable way to satisfy the long-term requirements for the reference frame. The GGOS goal is an origin definition at 1 mm or better and a temporal stability on the order of 0.1 mm/y, with similar numbers for the scale and orientation components. These goals are based on scientific requirements to address sea level rise with confidence, but other applications are not far behind. Recent studies including one by the US National Research Council has strongly stated the need and the urgency for the fundamental space geodesy network. Simulations are underway to examining accuracies for origin, scale and orientation of the resulting ITRF based on various network designs and system performance to determine the optimal global network to achieve this goal. To date these simulations indicate that 24 - 32 co-located stations are adequate to define the reference frame and a more dense GNSS and DORIS network will be required to distribute the reference frame to users anywhere on Earth. Stations in the new global network will require geologically stable sites with good weather, established infrastructure, and local support and personnel. GGOS wil seek groups that are interested in participation. GGOS intends to issues a Call for Participation of groups that would like to contribute in the network implementation and operation. Some examples of integrated stations currently in operation or under development will be presented. We will examine necessary conditions and challenges in designing a co-location station.
Communication network for decentralized remote tele-science during the Spacelab mission IML-2
NASA Technical Reports Server (NTRS)
Christ, Uwe; Schulz, Klaus-Juergen; Incollingo, Marco
1994-01-01
The ESA communication network for decentralized remote telescience during the Spacelab mission IML-2, called Interconnection Ground Subnetwork (IGS), provided data, voice conferencing, video distribution/conferencing and high rate data services to 5 remote user centers in Europe. The combination of services allowed the experimenters to interact with their experiments as they would normally do from the Payload Operations Control Center (POCC) at MSFC. In addition, to enhance their science results, they were able to make use of reference facilities and computing resources in their home laboratory, which typically are not available in the POCC. Characteristics of the IML-2 communications implementation were the adaptation to the different user needs based on modular service capabilities of IGS and the cost optimization for the connectivity. This was achieved by using a combination of traditional leased lines, satellite based VSAT connectivity and N-ISDN according to the simulation and mission schedule for each remote site. The central management system of IGS allows minimization of staffing and the involvement of communications personnel at the remote sites. The successful operation of IGS for IML-2 as a precursor network for the Columbus Orbital Facility (COF) has proven the concept for communications to support the operation of the COF decentralized scenario.
Mobile Robotics Activities in DOE Laboratories
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ron Lujan; Jerry Harbour; John T. Feddema
This paper will briefly outline major activities in Department of Energy (DOE) Laboratories focused on mobile platforms, both Unmanned Ground Vehicles (UGV’s) as well as Unmanned Air Vehicles (UAV’s). The activities will be discussed in the context of the science and technology construct used by the DOE Technology Roadmap for Robotics and Intelligent Machines (RIM)1 published in 1998; namely, Perception, Reasoning, Action, and Integration. The activities to be discussed span from research and development to deployment in field operations. The activities support customers in other agencies. The discussion of "perception" will include hyperspectral sensors, complex patterns discrimination, multisensor fusion andmore » advances in LADAR technologies, including real-world perception. "Reasoning" activities to be covered include cooperative controls, distributed systems, ad-hoc networks, platform-centric intelligence, and adaptable communications. The paper will discuss "action" activities such as advanced mobility and various air and ground platforms. In the RIM construct, "integration" includes the Human-Machine Integration. Accordingly the paper will discuss adjustable autonomy and the collaboration of operator(s) with distributed UGV’s and UAV’s. Integration also refers to the applications of these technologies into systems to perform operations such as perimeter surveillance, large-area monitoring and reconnaissance. Unique facilities and test beds for advanced mobile systems will be described. Given that this paper is an overview, rather than delve into specific detail in these activities, other more exhaustive references and sources will be cited extensively.« less
Syphilis testing practices in the Americas.
Trinh, Thuy T; Kamb, Mary L; Luu, Minh; Ham, D Cal; Perez, Freddy
2017-09-01
To present the findings of the Pan American Health Organization's 2014 survey on syphilis testing policies and practices in the Americas. Representatives of national/regional reference and large, lower-level laboratories from 35 member states were invited to participate. A semi-structured, electronically administered questionnaire collected data on syphilis tests, algorithms, equipment/commodities, challenges faced and basic quality assurance (QA) strategies employed (i.e. daily controls, standard operating procedures, technician training, participating in external QA programmes, on-site evaluations). The 69 participating laboratories from 30 (86%) member states included 41 (59%) national/regional reference and 28 (41%) lower-level laboratories. Common syphilis tests conducted were the rapid plasma reagin (RPR) (62% of surveyed laboratories), venereal disease research laboratory (VDRL) (54%), fluorescent treponemal antibody absorption (FTA-ABS) (41%) and Treponema pallidum haemagglutination assay (TPHA) (32%). Only three facilities reported using direct detection methods, and 28 (41% overall, 32% of lower-level facilities) used rapid tests. Most laboratories (62%) used only traditional testing algorithms (non-treponemal screening and treponemal confirmatory testing); however, 12% used only a reverse sequence algorithm (treponemal test first), and 14% employed both algorithms. Another nine (12%) laboratories conducted only one type of serologic test. Although most reference (97%) and lower-level (89%) laboratories used at least one QA strategy, only 16% reported using all five basic strategies. Commonly reported challenges were stock-outs of essential reagents or commodities (46%), limited staff training (73%) and insufficient equipment (39%). Many reference and clinical laboratories in the Americas face challenges in conducting appropriate syphilis testing and in ensuring quality of testing. © 2017 John Wiley & Sons Ltd The Pan-American Health Organization retains copyright and all other rights in the manuscript of this article as submitted for publication.
Design and Implementation Issues for Modern Remote Laboratories
ERIC Educational Resources Information Center
Guimaraes, E. G.; Cardozo, E.; Moraes, D. H.; Coelho, P. R.
2011-01-01
The design and implementation of remote laboratories present different levels of complexity according to the nature of the equipments operated by the remote laboratory, the requirements imposed on the accessing computers, the network linking the user to the laboratory, and the type of experiments the laboratory supports. This paper addresses the…
Gaspar, Pâmela Cristina; Wohlke, Bruna Lovizutto Protti; Brunialti, Milena Karina Coló; Pires, Ana Flávia; Kohiyama, Igor Massaki; Salomão, Reinaldo; Alonso Neto, José Boullosa; Júnior, Orlando da Costa Ferreira; Franchini, Miriam; Bazzo, Maria Luiza; Benzaken, Adele Schwartz
2018-05-01
The National Network for CD4+ T-lymphocyte counting of Brazil comprises 93 laboratories. This study reports the laboratory performances achieved in external quality assessment (EQA) rounds provides by Ministry of Health to evaluate the quality of the kits used and the performance of test by the technicians.Ten EQA rounds were analyzed according the EQA criteria aimed to evaluate individual laboratory performance on the basis of the accuracy of their results compared to the general mean obtained by all participating laboratories and the reproducibility of the results obtained between 2 samples from the same donor.The percentage of approved and failed laboratories in the EQAs tends to follow a uniform pattern. Since 2011, approval has remained above 80% and the failure rate has never exceeded 15%.EQA is very important to evaluate the performance of the laboratories, to identify monitor, and to resolve errors as quickly as possible.
[Investigation of reference intervals of blood gas and acid-base analysis assays in China].
Zhang, Lu; Wang, Wei; Wang, Zhiguo
2015-10-01
To investigate and analyze the upper and lower limits and their sources of reference intervals in blood gas and acid-base analysis assays. The data of reference intervals were collected, which come from the first run of 2014 External Quality Assessment (EQA) program in blood gas and acid-base analysis assays performed by National Center for Clinical Laboratories (NCCL). All the abnormal values and errors were eliminated. Data statistics was performed by SPSS 13.0 and Excel 2007 referring to upper and lower limits of reference intervals and sources of 7 blood gas and acid-base analysis assays, i.e. pH value, partial pressure of carbon dioxide (PCO2), partial pressure of oxygen (PO2), Na+, K+, Ca2+ and Cl-. Values were further grouped based on instrument system and the difference between each group were analyzed. There were 225 laboratories submitting the information on the reference intervals they had been using. The three main sources of reference intervals were National Guide to Clinical Laboratory Procedures [37.07% (400/1 079)], instructions of instrument manufactures [31.23% (337/1 079)] and instructions of reagent manufactures [23.26% (251/1 079)]. Approximately 35.1% (79/225) of the laboratories had validated the reference intervals they used. The difference of upper and lower limits in most assays among 7 laboratories was moderate, both minimum and maximum (i.e. the upper limits of pH value was 7.00-7.45, the lower limits of Na+ was 130.00-156.00 mmol/L), and mean and median (i.e. the upper limits of K+ was 5.04 mmol/L and 5.10 mmol/L, the upper limits of PCO2 was 45.65 mmHg and 45.00 mmHg, 1 mmHg = 0.133 kPa), as well as the difference in P2.5 and P97.5 between each instrument system group. It was shown by Kruskal-Wallis method that the P values of upper and lower limits of all the parameters were lower than 0.001, expecting the lower limits of Na+ with P value 0.029. It was shown by Mann-Whitney that the statistic differences were found among instrument system groups and between most of two instrument system groups in all assays. The difference of reference intervals of blood gas and acid-base analysis assays used in China laboratories is moderate, which is better than other specialties in clinical laboratories.
Khairnar, Krishna; Martin, Donald; Lau, Rachel; Ralevski, Filip; Pillai, Dylan R
2009-12-09
Accurate laboratory diagnosis of malaria species in returning travelers is paramount in the treatment of this potentially fatal infectious disease. A total of 466 blood specimens from returning travelers to Africa, Asia, and South/Central America with suspected malaria infection were collected between 2007 and 2009 at the reference public health laboratory. These specimens were assessed by reference microscopy, multipex real-time quantitative polymerase chain reaction (QPCR), and two rapid diagnostic immuno-chromatographic tests (ICT) in a blinded manner. Key clinical laboratory parameters such as limit of detection (LOD) analysis on clinical specimens by parasite stage, inter-reader variability of ICTs, staffing implications, quality assurance and cost analysis were evaluated. QPCR is the most analytically sensitive method (sensitivity 99.41%), followed by CARESTART (sensitivity 88.24%), and BINAXNOW (sensitivity 86.47%) for the diagnosis of malaria in returning travelers when compared to reference microscopy. However, microscopy was unable to specifically identify Plasmodia spp. in 18 out of 170 positive samples by QPCR. Moreover, the 17 samples that were negative by microscopy and positive by QPCR were also positive by ICTs. Quality assurance was achieved for QPCR by exchanging a blinded proficiency panel with another reference laboratory. The Kappa value of inter-reader variability among three readers for BINAXNOW and CARESTART was calculated to be 0.872 and 0.898 respectively. Serial dilution studies demonstrated that the QPCR cycle threshold correlates linearly with parasitemia (R(2) = 0.9746) in a clinically relevant dynamic range and retains a LOD of 11 rDNA copies/microl for P. falciparum, which was several log lower than reference microscopy and ICTs. LOD for QPCR is affected not only by parasitemia but the parasite stage distribution of each clinical specimen. QPCR was approximately 6-fold more costly than reference microscopy. These data suggest that multiplex QPCR although more costly confers a significant diagnostic advantage in terms of LOD compared to reference microscopy and ICTs for all four species. Quality assurance of QPCR is essential to the maintenance of proficiency in the clinical laboratory. ICTs showed good concordance between readers however lacked sensitivity for non-falciparum species due to antigenic differences and low parasitemia. Multiplex QPCR but not ICTs is an essential adjunct to microscopy in the reference laboratory detection of malaria species specifically due to the superior LOD. ICTs are better suited to the non-reference laboratory where lower specimen volumes challenge microscopy proficiency in the non-endemic setting.
Contribution of Charges in Polyvinyl Alcohol Networks to Marine Antifouling.
Yang, Wufang; Lin, Peng; Cheng, Daocang; Zhang, Longzhou; Wu, Yang; Liu, Yupeng; Pei, Xiaowei; Zhou, Feng
2017-05-31
Semi-interpenetrated polyvinyl alcohol polymer networks (SIPNs) were prepared by integrating various charged components into polyvinyl alcohol polymer. Contact angle measurement, attenuated total reflection Fourier transform infrared spectroscopy, field emission scanning electron microscopy, and tensile tests were used to characterize the physicochemical properties of the prepared SIPNs. To investigate the contribution of charges to marine antifouling, the adhesion behaviors of green algae Dunaliella tertiolecta and diatoms Navicula sp. in the laboratory and of the actual marine animals in field test were studied for biofouling assays. The results suggest that less algae accumulation densities are observed for neutral-, anionic-, and zwitterionic-component-integrated SIPNs. However, for the cationic SIPNs, despite the hydration shell induced by the ion-dipole interaction, the resistance to biofouling largely depends on the amount of cationic component because of the possible favorable electrostatic attraction between the cationic groups in SIPNs and the negatively charged algae. Considering that the preparation of novel nontoxic antifouling coating is a long-standing and cosmopolitan industrial challenge, the SIPNs may provide a useful reference for marine antifouling and some other relevant fields.
PILOT STUDY FOR ESTABLISHMENT OF A NETWORK OF COASTAL REFERENCE SITES
The National Oceanic and Atmospheric Administration (NOAA), U.S. Environmental Protection Agency (EPA), and the National Aeronautics and Space Administration (NASA) have joined in partnership for a pilot study for the establishment of a network of reference sites, the Coastal Int...
46 CFR 164.013-2 - Incorporation by reference.
Code of Federal Regulations, 2012 CFR
2012-10-01
.... All approved material incorporated by reference may be inspected at the National Archives and Records Administration (NARA), and at the U.S. Coast Guard, Lifesaving and Fire Safety Division (CG-ENG-4), 2100 2nd St... as follows: Underwriters Laboratories (UL) Underwriters Laboratories, Inc., P.O. Box 13995, Research...
Taking the Network on the Road: Portable Network Solutions for Computer Security Educators
ERIC Educational Resources Information Center
Rosenberg, Timothy; Hoffman, Lance J.
2006-01-01
Educational institutions that wish to implement a specialized teaching laboratory often have a variety of obstacles to overcome. Some of these obstacles are related to adapting existing classroom infrastructure, building the laboratory, and meeting the demands for multiple-use classrooms to maximize the return on investment. In some cases, such as…
75 FR 50987 - Privacy Act System of Records; National Animal Health Laboratory Network (NAHLN)
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-18
...] Privacy Act System of Records; National Animal Health Laboratory Network (NAHLN) AGENCY: Animal and Plant Health Inspection Service, USDA. ACTION: Notice of a proposed new system of records; request for comment. SUMMARY: The U.S. Department of Agriculture (USDA) proposes to add a new Privacy Act system of records to...
Automated Information System (AIS) Alarm System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hunteman, W.
1997-05-01
The Automated Information Alarm System is a joint effort between Los Alamos National Laboratory, Lawrence Livermore National Laboratory, and Sandia National Laboratory to demonstrate and implement, on a small-to-medium sized local area network, an automated system that detects and automatically responds to attacks that use readily available tools and methodologies. The Alarm System will sense or detect, assess, and respond to suspicious activities that may be detrimental to information on the network or to continued operation of the network. The responses will allow stopping, isolating, or ejecting the suspicious activities. The number of sensors, the sensitivity of the sensors, themore » assessment criteria, and the desired responses may be set by the using organization to meet their local security policies.« less
Kawai, Y; Nagai, Y; Ogawa, E; Kondo, H
2017-04-01
To provide target values for the manufacturers' survey of the Japanese Society for Laboratory Hematology (JSLH), accurate standard data from healthy volunteers were needed for the five-part differential leukocyte count. To obtain such data, JSLH required an antibody panel that achieved high specificity (particularly for mononuclear cells) using simple gating procedures. We developed a flow cytometric method for determining the differential leukocyte count (JSLH-Diff) and validated it by comparison with the flow cytometric differential leukocyte count of the International Council for Standardization in Haematology (ICSH-Diff) and the manual differential count obtained by microscopy (Manual-Diff). First, the reference laboratory performed an imprecision study of JSLH-Diff and ICSH-Diff, as well as performing comparison among JSLH-Diff, Manual-Diff, and ICSH-Diff. Then two reference laboratories and seven participating laboratories performed imprecision and accuracy studies of JSLH-Diff, Manual-Diff, and ICSH-Diff. Simultaneously, six manufacturers' laboratories provided their own representative values by using automated hematology analyzers. The precision of both JSLH-Diff and ICSH-Diff methods was adequate. Comparison by the reference laboratory showed that all correlation coefficients, slopes and intercepts obtained by the JSLH-Diff, ICSH-Diff, and Manual-Diff methods conformed to the criteria. When the imprecision and accuracy of JSLH-Diff were assessed at seven laboratories, the CV% for lymphocytes, neutrophils, monocytes, eosinophils, and basophils was 0.5~0.9%, 0.3~0.7%, 1.7~2.6%, 3.0~7.9%, and 3.8~10.4%, respectively. More than 99% of CD45 positive leukocytes were identified as normal leukocytes by JSLH-Diff. When JSLH-Diff method were validated by comparison with Manual-Diff and ICSH-Diff, JSLH-Diff showed good performance as a reference method. © 2016 John Wiley & Sons Ltd.
Ayling, Pete; Hill, Robert; Jassam, Nuthar; Kallner, Anders; Khatami, Zahra
2017-11-01
Background A logical consequence of the introduction of robotics and high-capacity analysers has seen a consolidation to larger units. This requires new structures and quality systems to ensure that laboratories deliver consistent and comparable results. Methods A spreadsheet program was designed to accommodate results from up to 12 different instruments/laboratories and present IQC data, i.e. Levey-Jennings and Youden plots and comprehensive numerical tables of the performance of each item. Input of data was made possible by a 'data loader' by which IQC data from the individual instruments could be transferred to the spreadsheet program on line. Results A set of real data from laboratories is used to populate the data loader and the networking software program. Examples are present from the analysis of variance components, the Levey-Jennings and Youden plots. Conclusions This report presents a software package that allows the simultaneous management and detailed monitoring of the performance of up to 12 different instruments/laboratories in a fully interactive mode. The system allows a quality manager of networked laboratories to have a continuous updated overview of the performance. This software package has been made available at the ACB website.
Wetherbee, Gregory A.; Martin, RoseAnn
2017-02-06
The U.S. Geological Survey Branch of Quality Systems operates the Precipitation Chemistry Quality Assurance Project (PCQA) for the National Atmospheric Deposition Program/National Trends Network (NADP/NTN) and National Atmospheric Deposition Program/Mercury Deposition Network (NADP/MDN). Since 1978, various programs have been implemented by the PCQA to estimate data variability and bias contributed by changing protocols, equipment, and sample submission schemes within NADP networks. These programs independently measure the field and laboratory components which contribute to the overall variability of NADP wet-deposition chemistry and precipitation depth measurements. The PCQA evaluates the quality of analyte-specific chemical analyses from the two, currently (2016) contracted NADP laboratories, Central Analytical Laboratory and Mercury Analytical Laboratory, by comparing laboratory performance among participating national and international laboratories. Sample contamination and stability are evaluated for NTN and MDN by using externally field-processed blank samples provided by the Branch of Quality Systems. A colocated sampler program evaluates the overall variability of NTN measurements and bias between dissimilar precipitation gages and sample collectors.This report documents historical PCQA operations and general procedures for each of the external quality-assurance programs from 2007 to 2016.
Diffusion-controlled reference material for VOC emissions testing: proof of concept.
Cox, S S; Liu, Z; Little, J C; Howard-Reed, C; Nabinger, S J; Persily, A
2010-10-01
Because of concerns about indoor air quality, there is growing awareness of the need to reduce the rate at which indoor materials and products emit volatile organic compounds (VOCs). To meet consumer demand for low emitting products, manufacturers are increasingly submitting materials to independent laboratories for emissions testing. However, the same product tested by different laboratories can result in very different emissions profiles because of a general lack of test validation procedures. There is a need for a reference material that can be used as a known emissions source and that will have the same emission rate when tested by different laboratories under the same conditions. A reference material was created by loading toluene into a polymethyl pentene film. A fundamental emissions model was used to predict the toluene emissions profile. Measured VOC emissions profiles using small-chamber emissions tests compared reasonably well to the emissions profile predicted using the emissions model, demonstrating the feasibility of the proposed approach to create a diffusion-controlled reference material. To calibrate emissions test chambers and improve the reproducibility of VOC emission measurements among different laboratories, a reference material has been created using a polymer film loaded with a representative VOC. Initial results show that the film's VOC emission profile measured in a conventional test chamber compares well to predictions based on independently determined material/chemical properties and a fundamental emissions model. The use of such reference materials has the potential to build consensus and confidence in emissions testing as well as 'level the playing field' for product testing laboratories and manufacturers.
2008-12-01
perceptions of formal and emergent leaders differ from those of non-leaders, and if so, how. We approach this topic through the lens of social network...analysis. 1.1 Social Networks The term “ social network” refers to a set of actors who are connected by a set of ties. Actors, often referred to as...the structure of any social system can be defined as a set of relations between all pairs of individuals who are members of the network (Krackhardt
Facility and Laboratory Equipment | Energy Systems Integration Facility |
Energy Systems Integration Facility is its infrastructure. In addition to extensive fixed laboratory . Photo of researchers testing building loads and power networks in the Systems Performance Laboratory
Cultured Neuronal Networks Express Complex Patterns of Activity and Morphological Memory
NASA Astrophysics Data System (ADS)
Raichman, Nadav; Rubinsky, Liel; Shein, Mark; Baruchi, Itay; Volman, Vladislav; Ben-Jacob, Eshel
The following sections are included: * Cultured Neuronal Networks * Recording the Network Activity * Network Engineering * The Formation of Synchronized Bursting Events * The Characterization of the SBEs * Highly-Active Neurons * Function-Form Relations in Cultured Networks * Analyzing the SBEs Motifs * Network Repertoire * Network under Hypothermia * Summary * Acknowledgments * References
Chuntarut, A; Tientadakul, P; Wongkrajang, P
2016-06-01
The Thailand National External Quality Assessment Scheme (NEQAS) for blood coagulation was established in 2005. The objective of this study was to collect data of coagulation laboratory practices and satisfaction of NEQAS member. Two hundred seventy-six questionnaires were sent to laboratories that are members of NEQAS to obtain data relating to coagulation laboratory practice and satisfaction in 2014. Data from this survey were compared with data from the survey conducted in 2005 to evaluate levels of improvement. Of 276 questionnaires sent, 212 (76.8%) were returned. Improvements were characterized by the number of laboratories that (i) decreased use of 3.8% sodium citrate as anticoagulant; (ii) implemented use of at least two control levels for internal quality control; and (iii) implemented reporting of reference values with results, as well as establishing their own reference range and using geometric mean as the denominator for international normalized ratio calculation. For overall satisfaction, 179 of 206 (86.9%) participant laboratories reported being satisfied or very satisfied. Improvements in coagulation laboratory practices in Thailand were observed in every step of the total testing process. However, additional improvements are still needed, such as determination and use of a local reference range. © 2016 John Wiley & Sons Ltd.
Pancrazio, Joseph J; Gray, Samuel A; Shubin, Yura S; Kulagina, Nadezhda; Cuttino, David S; Shaffer, Kara M; Eisemann, Kevin; Curran, Anthony; Zim, Bret; Gross, Guenter W; O'Shaughnessy, Thomas J
2003-10-01
Cultured neuronal networks, which have the capacity to respond to a wide range of neuroactive compounds, have been suggested to be useful for both screening known analytes and unknown compounds for acute neuropharmacologic effects. Extracellular recording from cultured neuronal networks provides a means for extracting physiologically relevant activity, i.e. action potential firing, in a noninvasive manner conducive for long-term measurements. Previous work from our laboratory described prototype portable systems capable of high signal-to-noise extracellular recordings from cardiac myocytes. The present work describes a portable system tailored to monitoring neuronal extracellular potentials that readily incorporates standardized microelectrode arrays developed by and in use at the University of North Texas. This system utilizes low noise amplifier and filter boards, a two-stage thermal control system with integrated fluidics and a graphical user interface for data acquisition and control implemented on a personal computer. Wherever possible, off-the-shelf components have been utilized for system design and fabrication. During use with cultured neuronal networks, the system typically exhibits input referred noise levels of only 4-6 microVRMS, such that extracellular potentials exceeding 40 microV can be readily resolved. A flow rate of up to 1 ml/min was achieved while the cell recording chamber temperature was maintained within a range of 36-37 degrees C. To demonstrate the capability of this system to resolve small extracellular potentials, pharmacological experiments with cultured neuronal networks have been performed using ion channel blockers, tetrodotoxin and tityustoxin. The implications of the experiments for neurotoxin detection are discussed.
PHILIS (PORTABLE HIGH-THROUGHPUT INTEGRATED LABORATORY IDENTIFICATION SYSTEM)
These mobile laboratory assets, for the on-site analysis of chemical warfare agent (CWA) and toxic industrial compound (TIC) contaminated environmental samples, are part of the evolving Environmental Response Laboratory Network (ERLN).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Akyol, Bora A.; Allwardt, Craig H.; Beech, Zachary W.
VOLTTRON is a flexible, reliable, and scalable platform for distributed control and sensing. VOLTTRON serves in four primary roles: •A reference platform for researchers to quickly develop control applications for transactive energy. •A reference platform with flexible data store support for energy analytics applications either in academia or in commercial enterprise. •A platform from which commercial enterprise can develop products without license issues and easily integrate into their product line. •An accelerator to drive industry adoption of transactive energy and advanced building energy analytics. Pacific Northwest National Laboratory, with funding from the U.S. Department of Energy’s Building Technologies Office, developedmore » and maintains VOLTTRON as an open-source community project. VOLTTRON source code includes agent execution software; agents that perform critical services that enable and enhance VOLTTRON functionality; and numerous agents that utilize the platform to perform a specific function (fault detection, demand response, etc.). The platform supports energy, operational, and financial transactions between networked entities (equipment, organizations, buildings, grid, etc.) and enhance the control infrastructure of existing buildings through the use of open-source device communication, control protocols, and integrated analytics.« less
A new apparatus for on-site calibration of gamma dose rate monitors
NASA Astrophysics Data System (ADS)
Zhang, Yu; Chen, Bo; Zhao, Chao; Zhuo, Weihai
2018-01-01
In order to carry out on-site calibrations of environmental gamma dose rate monitors, a new irradiation apparatus was developed in this study. The apparatus mainly consists of a piece of 137Cs source, a set of beam attenuators, and 3 built-in laser rangefinders, and it can be remotely controlled by using a laptop through WiFi network. With an activity of 4.6 × 108 Bq of 137Cs source, the reference air kerma rate could be adjusted from 0.26 μGy h-1 to 140 μGy h-1 by changing the calibration distance from 0.5 m to 5 m and using different beam attenuators (or none), and both the reproducibility and the homogeneity of reference radiation were better than 97%. The overall uncertainty of the calibration was estimated to be 6.5% (k = 2). Both the laboratory and field experiments confirmed that the calibration method met the requirements of ISO 4037-1. As the advantages of portability and simplicity, it is considered that the new irradiation apparatus is applicable to stationary gamma radiation monitors for on-site calibration.
Laboratory twinning to build capacity for rabies diagnosis.
Fooks, Anthony R; Drew, Trevor W; Tu, Changchun
2016-03-05
In 2009, the UK's OIE Reference Laboratory for rabies, based at the APHA in Weybridge, was awarded a project to twin with the Changchun Veterinary Research Institute in the People's Republic of China to help the institute develop the skills and methods necessary to become an OIE Reference Laboratory itself. Here, Tony Fooks, Trevor Drew and Changchun Tu describe the OIE's twinning project and the success that has since been realised in China. British Veterinary Association.
Vinklárková, Bára; Chromý, Vratislav; Šprongl, Luděk; Bittová, Miroslava; Rikanová, Milena; Ohnútková, Ivana; Žaludová, Lenka
2015-01-01
To select a Kjeldahl procedure suitable for the determination of total protein in reference materials used in laboratory medicine, we reviewed in our previous article Kjeldahl methods adopted by clinical chemistry and found an indirect two-step analysis by total Kjeldahl nitrogen corrected for its nonprotein nitrogen and a direct analysis made on isolated protein precipitates. In this article, we compare both procedures on various reference materials. An indirect Kjeldahl method gave falsely lower results than a direct analysis. Preliminary performance parameters qualify the direct Kjeldahl analysis as a suitable primary reference procedure for the certification of total protein in reference laboratories.
van Asselt-Goverts, A E; Embregts, P J C M; Hendriks, A H C; Wegman, K M; Teunisse, J P
2015-05-01
The aim of this study was to determine the similarities and differences in social network characteristics, satisfaction and wishes with respect to the social network between people with mild or borderline intellectual disabilities (ID), people with autism spectrum disorders (ASD) and a reference group. Data were gathered from 105 young adults living independently in the community. The social networks of people with ID and ASD are more restricted than those of the reference group. Compared with the other groups, people with ASD are less often satisfied with their networks. Each group has its own characteristics, issues and wishes with respect to their social network. Practical measures to enable professionals to adapt to these issues are discussed.
Advanced On-the-Job Training System: System Specification
1990-05-01
3.1.5.2.10 Evaluation Subsystem spotfor the Traking Devopment and Deliery Subsystem ..... 22 3.1.5.2.11 TrIning Development=dDelivery Subsystem sL...e. Alsys Ada compiler f. Ethernet Local Area Network reference manual(s) g. Infotron 992 network reference manual(s) h. Computer Program Source...1989 a. Daily check of mainframe components, including all elements critical to support the terminal network . b. Restoration of mainframe equipment
Video networking of cardiac catheterization laboratories.
Tobis, J; Aharonian, V; Mansukhani, P; Kasaoka, S; Jhandyala, R; Son, R; Browning, R; Youngblood, L; Thompson, M
1999-02-01
The purpose of this study was to assess the feasibility and accuracy of a video telecommunication network to transmit coronary images to provide on-line interaction between personnel in a cardiac catheterization laboratory and a remote core laboratory. A telecommunication system was installed in the cardiac catheterization laboratory at Kaiser Hospital, Los Angeles, and the core laboratory at the University of California, Irvine, approximately 40 miles away. Cineangiograms, live fluoroscopy, intravascular ultrasound studies and images of the catheterization laboratory were transmitted in real time over a dedicated T1 line at 768 kilobytes/second at 15 frames/second. These cases were performed during a clinical study of angiographic guidance versus intravascular ultrasound (IVUS) guidance of stent deployment. During the cases the core laboratory performed quantitative analysis of the angiograms and ultrasound images. Selected images were then annotated and transmitted back to the catheterization laboratory to facilitate discussion during the procedure. A successful communication hookup was obtained in 39 (98%) of 40 cases. Measurements of angiographic parameters were very close between the original cinefilm and the transmitted images. Quantitative analysis of the ultrasound images showed no significant difference in any of the diameter or cross-sectional area measurements between the original ultrasound tape and the transmitted images. The telecommunication link during the interventional procedures had a significant impact in 23 (58%) of 40 cases affecting the area to be treated, the size of the inflation balloon, recognition of stent underdeployment, or the existence of disease in other areas that was not noted on the original studies. Current video telecommunication systems provide high-quality images on-line with accurate representation of cineangiograms and intravascular ultrasound images. This system had a significant impact on 58% of the cases in this small clinical trial. Telecommunication networks between hospitals and a central core laboratory may facilitate physician training and improve technical skills and judgement during interventional procedures. This project has implications for how multicenter clinical trials could be operated through telecommunication networks to ensure conformity with the protocol.
Pattern recognition and classification of vibrational spectra by artificial neural networks
NASA Astrophysics Data System (ADS)
Yang, Husheng
1999-10-01
A drawback of current open-path Fourier transform infrared (OP/FT-IR) systems is that they need a human expert to determine those compounds that may be quantified from a given spectrum. In this study, three types of artificial neural networks were used to alleviate this problem. Firstly, multi-layer feed-forward neural networks were used to automatically recognize compounds in an OP/FT-IR spectrum. Each neural network was trained to recognize one compound in the presence of up to ten interferents in an OP/FT-IR spectrum. The networks were successfully used to recognize five alcohols and two chlorinated compounds in field-measured controlled-release OP/FT-IR spectra of mixtures of these compounds. It has also been demonstrated that a neural network could correctly identify a spectrum in the presence of an interferent that was not included in the training set and could also reject interferents it has not seen before. Secondly, the possibility of using one- and two- dimensional Kohonen self-organizing maps (SOMs) to recognize similarities in low-resolution vapor-phase infrared spectra without any additional information has been investigated. Both full-range reference spectra and open-path window reference spectra were used to train the networks and the trained networks were then used to classify the reference spectra into several groups. The results showed that the SOMs obtained from the two different training sets were quite different, and it is more appropriate to use the second SOM in OP/FT-IR spectrometry. Thirdly, vapor-phase FT-IR reference spectra of five alcohols along with four baseline spectra were encoded as prototype vectors for a Hopfield network. Inclusion of the baseline spectra allowed the network to classify spectra as unknowns, when the reference spectra of these compounds were not stored as prototype vectors in the network. The network could identify each of the 5 alcohols correctly even in the presence of noise and interfering compounds. Finally, one- and two-dimensional Kohonen SOMs were also successfully used for the unsupervised differentiation of the Fourier transform Raman spectra of hardwoods from softwoods. A semi-quantitative method that is based on the Euclidean distances of the weight matrix has been developed to assist the automatic clustering of the neurons in a two-dimensional SOM.
The theory of reference values: an unfinished symphony.
Siest, Gerard; Henny, Joseph; Gräsbeck, Ralph; Wilding, Peter; Petitclerc, Claude; Queraltó, Josep M; Hyltoft Petersen, Peter
2013-01-01
The history of the theory of reference values can be written as an unfinished symphony. The first movement, allegro con fuoco, played from 1960 to 1980: a mix of themes devoted to the study of biological variability (intra-, inter-individual, short- and long-term), preanalytical conditions, standardization of analytical methods, quality control, statistical tools for deriving reference limits, all of them complex variations developed on a central melody: the new concept of reference values that would replace the notion of normality whose definition was unclear. Additional contributions (multivariate reference values, use of reference limits from broad sets of patient data, drug interferences) conclude the movement on the variability of laboratory tests. The second movement, adagio, from 1980 to 2000, slowly develops and implements initial works. International and national recommendations were published by the IFCC-LM (International Federation of Clinical Chemistry and Laboratory Medicine) and scientific societies [French (SFBC), Spanish (SEQC), Scandinavian societies…]. Reference values are now topics of many textbooks and of several congresses, workshops, and round tables that are organized all over the world. Nowadays, reference values are part of current practice in all clinical laboratories, but not without difficulties, particularly for some laboratories to produce their own reference values and the unsuitability of the concept with respect to new technologies such as HPLC, GCMS, and PCR assays. Clinicians through consensus groups and practice guidelines have introduced their own tools, the decision limits, likelihood ratios and Reference Change Value (RCV), creating confusion among laboratorians and clinicians in substituting reference values and decision limits in laboratory reports. The rapid development of personalized medicine will eventually call for the use of individual reference values. The beginning of the second millennium is played allegro ma non-troppo from 2000 to 2012: the theory of reference values is back into fashion. The need to revise the concept is emerging. The manufacturers make a friendly pressure to facilitate the integration of Reference Intervals (RIs) in their technical documentation. Laboratorians are anxiously awaiting the solutions for what to do. The IFCC-LM creates Reference Intervals and Decision Limits Committee (C-RIDL) in 2005. Simultaneously, a joint working group IFCC-CLSI is created on the same topic. In 2008 the initial recommendations of IFCC-LM are revised and new guidelines are published by the Clinical and Laboratory Standards Institute (CLSI C28-A3). Fundamentals of the theory of reference values are not changed, but new avenues are explored: RIs transference, multicenter reference intervals, and a robust method for deriving RIs from small number of subjects. Concomitantly, other statistical methods are published such as bootstraps calculation and partitioning procedures. An alternative to recruiting healthy subjects proposes the use of biobanks conditional to the availability of controlled preanalytical conditions and of bioclinical data. The scope is also widening to include veterinary biology! During the early 2000s, several groups proposed the concept of 'Universal RIs' or 'Global RIs'. Still controversial, their applications await further investigations. The fourth movement, finale: beyond the methodological issues (statistical and analytical essentially), important questions remain unanswered. Do RIs intervene appropriately in medical decision-making? Are RIs really useful to the clinicians? Are evidence-based decision limits more appropriate? It should be appreciated that many laboratory tests represent a continuum that weakens the relevance of RIs. In addition, the boundaries between healthy and pathological states are shady areas influenced by many biological factors. In such a case the use of a single threshold is questionable. Wherever it will apply, individual reference values and reference change values have their place. A variation on an old theme! It is strange that in the period of personalized medicine (that is more stratified medicine), the concept of reference values which is based on stratification of homogeneous subgroups of healthy people could not be discussed and developed in conjunction with the stratification of sick patients. That is our message for the celebration of the 50th anniversary of Clinical Chemistry and Laboratory Medicine. Prospects are broad, enthusiasm is not lacking: much remains to be done, good luck for the new generations!
Fernald, Douglas; Hamer, Mika; James, Kathy; Tutt, Brandon; West, David
2015-01-01
Family medicine and internal medicine physicians order diagnostic laboratory tests for nearly one-third of patient encounters in an average week, yet among medical errors in primary care, an estimated 15% to 54% are attributed to laboratory testing processes. From a practice improvement perspective, we (1) describe the need for laboratory testing process quality improvements from the perspective of primary care practices, and (2) describe the approaches and resources needed to implement laboratory testing process quality improvements in practice. We applied practice observations, process mapping, and interviews with primary care practices in the Shared Networks of Colorado Ambulatory Practices and Partners (SNOCAP)-affiliated practice-based research networks that field-tested in 2013 a laboratory testing process improvement toolkit. From the data collected in each of the 22 participating practices, common testing quality issues included, but were not limited to, 3 main testing process steps: laboratory test preparation, test tracking, and patient notification. Three overarching qualitative themes emerged: practices readily acknowledge multiple laboratory testing process problems; practices know that they need help addressing the issues; and practices face challenges with finding patient-centered solutions compatible with practice priorities and available resources. While practices were able to get started with guidance and a toolkit to improve laboratory testing processes, most did not seem able to achieve their quality improvement aims unassisted. Providing specific guidance tools with practice facilitation or other rapid-cycle quality improvement support may be an effective approach to improve common laboratory testing issues in primary care. © Copyright 2015 by the American Board of Family Medicine.
GFT centrality: A new node importance measure for complex networks
NASA Astrophysics Data System (ADS)
Singh, Rahul; Chakraborty, Abhishek; Manoj, B. S.
2017-12-01
Identifying central nodes is very crucial to design efficient communication networks or to recognize key individuals of a social network. In this paper, we introduce Graph Fourier Transform Centrality (GFT-C), a metric that incorporates local as well as global characteristics of a node, to quantify the importance of a node in a complex network. GFT-C of a reference node in a network is estimated from the GFT coefficients derived from the importance signal of the reference node. Our study reveals the superiority of GFT-C over traditional centralities such as degree centrality, betweenness centrality, closeness centrality, eigenvector centrality, and Google PageRank centrality, in the context of various arbitrary and real-world networks with different degree-degree correlations.
Gradishar, William; Johnson, KariAnne; Brown, Krystal; Mundt, Erin; Manley, Susan
2017-07-01
There is a growing move to consult public databases following receipt of a genetic test result from a clinical laboratory; however, the well-documented limitations of these databases call into question how often clinicians will encounter discordant variant classifications that may introduce uncertainty into patient management. Here, we evaluate discordance in BRCA1 and BRCA2 variant classifications between a single commercial testing laboratory and a public database commonly consulted in clinical practice. BRCA1 and BRCA2 variant classifications were obtained from ClinVar and compared with the classifications from a reference laboratory. Full concordance and discordance were determined for variants whose ClinVar entries were of the same pathogenicity (pathogenic, benign, or uncertain). Variants with conflicting ClinVar classifications were considered partially concordant if ≥1 of the listed classifications agreed with the reference laboratory classification. Four thousand two hundred and fifty unique BRCA1 and BRCA2 variants were available for analysis. Overall, 73.2% of classifications were fully concordant and 12.3% were partially concordant. The remaining 14.5% of variants had discordant classifications, most of which had a definitive classification (pathogenic or benign) from the reference laboratory compared with an uncertain classification in ClinVar (14.0%). Here, we show that discrepant classifications between a public database and single reference laboratory potentially account for 26.7% of variants in BRCA1 and BRCA2 . The time and expertise required of clinicians to research these discordant classifications call into question the practicality of checking all test results against a database and suggest that discordant classifications should be interpreted with these limitations in mind. With the increasing use of clinical genetic testing for hereditary cancer risk, accurate variant classification is vital to ensuring appropriate medical management. There is a growing move to consult public databases following receipt of a genetic test result from a clinical laboratory; however, we show that up to 26.7% of variants in BRCA1 and BRCA2 have discordant classifications between ClinVar and a reference laboratory. The findings presented in this paper serve as a note of caution regarding the utility of database consultation. © AlphaMed Press 2017.
Electronic Reference Library: Silverplatter's Database Networking Solution.
ERIC Educational Resources Information Center
Millea, Megan
Silverplatter's Electronic Reference Library (ERL) provides wide area network access to its databases using TCP/IP communications and client-server architecture. ERL has two main components: The ERL clients (retrieval interface) and the ERL server (search engines). ERL clients provide patrons with seamless access to multiple databases on multiple…
Library and Information Networks: Centralization and Decentralization.
ERIC Educational Resources Information Center
Segal, JoAnn S.
1988-01-01
Describes the development of centralized library networks and the current factors that make library sharing on a smaller scale feasible. The discussion covers the need to decide the level at which library cooperation should occur and the possibility of linking via the Open System Interface Reference Model. (37 references) (CLB)
Two Web-Based Laboratories of the FisL@bs Network: Hooke's and Snell's Laws
ERIC Educational Resources Information Center
de la Torre, L.; Sanchez, J.; Dormido, S.; Sanchez, J. P.; Yuste, M.; Carreras, C.
2011-01-01
FisL@bs is a network of remote and virtual laboratories for physics university education via the Internet that offers students the possibility of performing hands-on experiments in different fields of physics in two ways: simulation and real remote operation. This paper gives a detailed account of a novel way in physics in which distance learning…
Effluent-Monitoring Procedures: Basic Laboratory Skills. Student Reference Manual.
ERIC Educational Resources Information Center
Engel, William T.; And Others
This is one of several short-term courses developed to assist in the training of waste water treatment plant operational personnel in the tests, measurements, and report preparation required for compliance with their NPDES Permits. This Student Reference Manual provides a review of basic mathematics as it applies to the chemical laboratory. The…
Quintyn-Ranty, Marie-Laure; Gordien, Karine; Caveriviere, Paul; Mery, Éliane; Jamme-Lallemand, Muriel; Wuithier, Pascal; Palasse, Julien; Reyre, Joelle; Laborie, Vincent; Despax, Brigitte; Rolland, Véronique; Thibaut, Isabelle; Maissongrosse, Véronique; Escourrou, Ghislaine; Duprez-Paumier, Raphaëlle; Bauvin, Éric; Jacob, Michel; Lacroix-Triki, Magali
2015-10-01
Pathologists commonly face breast lesions that are difficult to diagnose. To reduce second opinion delay, erase geographical barrier and provide continuing education, we aimed to develop a telepathology-based regional network of pathologists. With the support of ONCOMIP network, we founded a peer-group named SENOPATH, composed of experienced breast pathologists practising in private laboratories, university hospitals or comprehensive cancer center in the region of Midi-Pyrénées in France. Submitted cases are digitalized at the University Hospital, stored in a shared space with a possible access via Internet prior to the SENOPATH sessions. The group meets monthly, via a synchronized webinar and multihead microscope session. A consensual diagnosis and final pathology report is issued for each case, and sent to the referring clinician via the patient medical file securely hosted by ONCOMIP. Between 2012 and 2014, 142 cases were reviewed, for either diagnostic 'routine' difficulty or rare histological type. The SENOPATH group, also regularly called by oncologists to solve difficult cases, has considerably improved the pathologist network in Southern France. Supported by the webinar tool, its educational impact is prominent, with a considerable progress in the region with regards to standardization of pathology processes, literature review and knowledge sharing. Copyright © 2015 Société Française du Cancer. Published by Elsevier Masson SAS. All rights reserved.
Abayomi, A; Goodridge, W; Asika, O
2006-12-01
Biomedical and demographic data capture and the subsequent management of such information are critical factors in the implementation of any level of healthcare prevention and treatment program. The developing world is seriously handicapped by lack of infrastructure to acquire such data let alone manipulate the information banks for projections, forecasting and priority project planning. With this in mind we set about to use the recent proliferation of wireless cellular networks and easily accessible Personal Digital Assistants (PDA), to devise a means of collecting such data even from the most remote primary healthcare facility. Our priority is aimed at initially at providing a support technology for the HIV expanded program. This technology can be implemented in the absence of computerization and regular power supply. Utilizing a PDA to capture patient data (demographic, clinical and laboratory parameters), the healthcare giver can use a wireless link between the PDA and a cellular phone to transfer the data to a central medical data base. These can then become permanent and secure data banks for future use by health providers, either at the same location or at other health facility that have authorized access to the data bank. It also affords a platform for integrating reference labs into the network as well as the opportunity to disseminate continuing medical educational material. The network can also be adapted to electronic remote consultations and eventually its data banks can be assimilated into protocols of artificial intelligence and data mining.
2015-05-01
application ,1 while the simulated PLC software is the open source ModbusPal Java application . When queried using the Modbus TCP protocol, ModbusPal reports...and programmable logic controller ( PLC ) components. The HMI and PLC components were instantiated with software and installed in multiple virtual...creating and capturing HMI– PLC network traffic over a 24-h period in the virtualized network and inspect the packets for errors. Test the
Structure and Evolution of Scientific Collaboration Networks in a Modern Research Collaboratory
ERIC Educational Resources Information Center
Pepe, Alberto
2010-01-01
This dissertation is a study of scientific collaboration at the Center for Embedded Networked Sensing (CENS), a modern, multi-disciplinary, distributed laboratory involved in sensor network research. By use of survey research and network analysis, this dissertation examines the collaborative ecology of CENS in terms of three networks of…
GCR Simulator Reference Field and a Spectral Approach for Laboratory Simulation
NASA Technical Reports Server (NTRS)
Slaba, Tony C.; Blattnig, Steve R.; Norbury, John W.; Rusek, Adam; La Tessa, Chiara; Walker, Steven A.
2015-01-01
The galactic cosmic ray (GCR) simulator at the NASA Space Radiation Laboratory (NSRL) is intended to deliver the broad spectrum of particles and energies encountered in deep space to biological targets in a controlled laboratory setting. In this work, certain aspects of simulating the GCR environment in the laboratory are discussed. Reference field specification and beam selection strategies at NSRL are the main focus, but the analysis presented herein may be modified for other facilities. First, comparisons are made between direct simulation of the external, free space GCR field and simulation of the induced tissue field behind shielding. It is found that upper energy constraints at NSRL limit the ability to simulate the external, free space field directly (i.e. shielding placed in the beam line in front of a biological target and exposed to a free space spectrum). Second, variation in the induced tissue field associated with shielding configuration and solar activity is addressed. It is found that the observed variation is likely within the uncertainty associated with representing any GCR reference field with discrete ion beams in the laboratory, given current facility constraints. A single reference field for deep space missions is subsequently identified. Third, an approach for selecting beams at NSRL to simulate the designated reference field is presented. Drawbacks of the proposed methodology are discussed and weighed against alternative simulation strategies. The neutron component and track structure characteristics of the simulated field are discussed in this context.
Iorio, Francesco; Bernardo-Faura, Marti; Gobbi, Andrea; Cokelaer, Thomas; Jurman, Giuseppe; Saez-Rodriguez, Julio
2016-12-20
Networks are popular and powerful tools to describe and model biological processes. Many computational methods have been developed to infer biological networks from literature, high-throughput experiments, and combinations of both. Additionally, a wide range of tools has been developed to map experimental data onto reference biological networks, in order to extract meaningful modules. Many of these methods assess results' significance against null distributions of randomized networks. However, these standard unconstrained randomizations do not preserve the functional characterization of the nodes in the reference networks (i.e. their degrees and connection signs), hence including potential biases in the assessment. Building on our previous work about rewiring bipartite networks, we propose a method for rewiring any type of unweighted networks. In particular we formally demonstrate that the problem of rewiring a signed and directed network preserving its functional connectivity (F-rewiring) reduces to the problem of rewiring two induced bipartite networks. Additionally, we reformulate the lower bound to the iterations' number of the switching-algorithm to make it suitable for the F-rewiring of networks of any size. Finally, we present BiRewire3, an open-source Bioconductor package enabling the F-rewiring of any type of unweighted network. We illustrate its application to a case study about the identification of modules from gene expression data mapped on protein interaction networks, and a second one focused on building logic models from more complex signed-directed reference signaling networks and phosphoproteomic data. BiRewire3 it is freely available at https://www.bioconductor.org/packages/BiRewire/ , and it should have a broad application as it allows an efficient and analytically derived statistical assessment of results from any network biology tool.
Steinmetz, Josiane; Schiele, Françoise; Gueguen, René; Férard, Georges; Henny, Joseph
2007-01-01
The improvement of the consistency of gamma-glutamyltransferase (GGT) activity results among different assays after calibration with a common material was estimated. We evaluated if this harmonization could lead to reference limits common to different routine methods. Seven laboratories measured GGT activity using their own routine analytical system both according to the manufacturer's recommendation and after calibration with a multi-enzyme calibrator [value assigned by the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) reference procedure]. All samples were re-measured using the IFCC reference procedure. Two groups of subjects were selected in each laboratory: a group of healthy men aged 18-25 years without long-term medication and with alcohol consumption less than 44 g/day and a group of subjects with elevated GGT activity. The day-to-day coefficients of variation were less than 2.9% in each laboratory. The means obtained in the group of healthy subjects without common calibration (range of the means 16-23 U/L) were significantly different from those obtained by the IFCC procedure in five laboratories. After calibration, the means remained significantly different from the IFCC procedure results in only one laboratory. For three calibrated methods, the slope values of linear regression vs. the IFCC procedure were not different from the value 1. The results obtained with these three methods for healthy subjects (n=117) were gathered and reference limits were calculated. These were 11-49 U/L (2.5th-97.5th percentiles). The calibration also improved the consistency of elevated results when compared to the IFCC procedure. The common calibration improved the level of consistency between different routine methods. It permitted to define common reference limits which are quite similar to those proposed by the IFCC. This approach should lead to a real benefit in terms of prevention, screening, diagnosis, therapeutic monitoring and for epidemiological studies.
An improved AVC strategy applied in distributed wind power system
NASA Astrophysics Data System (ADS)
Zhao, Y. N.; Liu, Q. H.; Song, S. Y.; Mao, W.
2016-08-01
Traditional AVC strategy is mainly used in wind farm and only concerns about grid connection point, which is not suitable for distributed wind power system. Therefore, this paper comes up with an improved AVC strategy applied in distributed wind power system. The strategy takes all nodes of distribution network into consideration and chooses the node having the most serious voltage deviation as control point to calculate the reactive power reference. In addition, distribution principles can be divided into two conditions: when wind generators access to network on single node, the reactive power reference is distributed according to reactive power capacity; when wind generators access to network on multi-node, the reference is distributed according to sensitivity. Simulation results show the correctness and reliability of the strategy. Compared with traditional control strategy, the strategy described in this paper can make full use of generators reactive power output ability according to the distribution network voltage condition and improve the distribution network voltage level effectively.
The Value Estimation of an HFGW Frequency Time Standard for Telecommunications Network Optimization
NASA Astrophysics Data System (ADS)
Harper, Colby; Stephenson, Gary
2007-01-01
The emerging technology of gravitational wave control is used to augment a communication system using a development roadmap suggested in Stephenson (2003) for applications emphasized in Baker (2005). In the present paper consideration is given to the value of a High Frequency Gravitational Wave (HFGW) channel purely as providing a method of frequency and time reference distribution for use within conventional Radio Frequency (RF) telecommunications networks. Specifically, the native value of conventional telecommunications networks may be optimized by using an unperturbed frequency time standard (FTS) to (1) improve terminal navigation and Doppler estimation performance via improved time difference of arrival (TDOA) from a universal time reference, and (2) improve acquisition speed, coding efficiency, and dynamic bandwidth efficiency through the use of a universal frequency reference. A model utilizing a discounted cash flow technique provides an estimation of the additional value using HFGW FTS technology could bring to a mixed technology HFGW/RF network. By applying a simple net present value analysis with supporting reference valuations to such a network, it is demonstrated that an HFGW FTS could create a sizable improvement within an otherwise conventional RF telecommunications network. Our conservative model establishes a low-side value estimate of approximately 50B USD Net Present Value for an HFGW FTS service, with reasonable potential high-side values to significant multiples of this low-side value floor.
Optical Fiber Power Meter Comparison Between NIST and NIM.
Vayshenker, I; Livigni, D J; Li, X; Lehman, J H; Li, J; Xiong, L M; Zhang, Z X
2010-01-01
We describe the results of a comparison of reference standards between the National Institute of Standards and Technology (NIST-USA) and National Institute of Metrology (NIM-China). We report optical fiber-based power measurements at nominal wavelengths of 1310 nm and 1550 nm. We compare the laboratories' reference standards by means of a commercial optical power meter. Measurement results showed the largest difference of less than 2.6 parts in 10(3), which is within the combined standard (k = 1) uncertainty for the laboratories' reference standards.
Pine, P S; Boedigheimer, M; Rosenzweig, B A; Turpaz, Y; He, Y D; Delenstarr, G; Ganter, B; Jarnagin, K; Jones, W D; Reid, L H; Thompson, K L
2008-11-01
Effective use of microarray technology in clinical and regulatory settings is contingent on the adoption of standard methods for assessing performance. The MicroArray Quality Control project evaluated the repeatability and comparability of microarray data on the major commercial platforms and laid the groundwork for the application of microarray technology to regulatory assessments. However, methods for assessing performance that are commonly applied to diagnostic assays used in laboratory medicine remain to be developed for microarray assays. A reference system for microarray performance evaluation and process improvement was developed that includes reference samples, metrics and reference datasets. The reference material is composed of two mixes of four different rat tissue RNAs that allow defined target ratios to be assayed using a set of tissue-selective analytes that are distributed along the dynamic range of measurement. The diagnostic accuracy of detected changes in expression ratios, measured as the area under the curve from receiver operating characteristic plots, provides a single commutable value for comparing assay specificity and sensitivity. The utility of this system for assessing overall performance was evaluated for relevant applications like multi-laboratory proficiency testing programs and single-laboratory process drift monitoring. The diagnostic accuracy of detection of a 1.5-fold change in signal level was found to be a sensitive metric for comparing overall performance. This test approaches the technical limit for reliable discrimination of differences between two samples using this technology. We describe a reference system that provides a mechanism for internal and external assessment of laboratory proficiency with microarray technology and is translatable to performance assessments on other whole-genome expression arrays used for basic and clinical research.
Teaching Network Security with IP Darkspace Data
ERIC Educational Resources Information Center
Zseby, Tanja; Iglesias Vázquez, Félix; King, Alistair; Claffy, K. C.
2016-01-01
This paper presents a network security laboratory project for teaching network traffic anomaly detection methods to electrical engineering students. The project design follows a research-oriented teaching principle, enabling students to make their own discoveries in real network traffic, using data captured from a large IP darkspace monitor…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pepper, S. E.; Bachner, K.; Gomera, J.
Brookhaven National Laboratory’s (BNL’s) Nonproliferation and National Security Department hosted the Next Generation Safeguards Professional Network (NGSPN) at BNL September 6-9, 2016. Thirteen representatives from seven Department of Energy National Laboratories, including two from BNL, participated in the four-day meeting. The NGSPN meeting was sponsored by the Office of International Nuclear Safeguards (NA-241) of the National Nuclear Security Administration, which provided funding for BNL’s development and conduct of the meeting program and the participant’s labor and travel. NGSPN meetings were previously held at Savannah River National Laboratory, Oak Ridge National Laboratory, Idaho National Laboratory, Sandia National Laboratories, and Los Alamosmore » National Laboratory. The purpose of NGSPN is to provide a forum for early-career international safeguards practitioners to network with their peers, to meet international safeguards experts from other institutions and to learn about organizations other than their employers who contribute to international safeguards.« less
NASA Astrophysics Data System (ADS)
Arzilli, F.; Cilona, A.; Mancini, L.; Tondi, E.
2016-09-01
In this work we propose a new methodology to calculate pore connectivity in granular rocks. This method is useful to characterize the pore networks of natural and laboratory compaction bands (CBs), and compare them with the host rock pore network. Data were collected using the synchrotron X-ray microtomography technique and quantitative analyses were carried out using the Pore3D software library. The porosity was calculated from segmented tridimensional images of deformed and pristine rocks. A process of skeletonization of the pore space was used to obtain the number of connected pores within the rock volume. By analyzing the skeletons the differences between natural and laboratory CBs were highlighted. The natural CB has a lower porosity than to the laboratory one. In natural CBs, the grain contacts appear welded, whereas laboratory CBs show irregular pore shape. Moreover, we assessed for the first time how pore connectivity evolves as a function of deformation, documenting the mechanism responsible for pore connectivity drop within the CBs.
Two web-based laboratories of the FisL@bs network: Hooke's and Snell's laws
NASA Astrophysics Data System (ADS)
de la Torre, L.; Sánchez, J.; Dormido, S.; Sánchez, J. P.; Yuste, M.; Carreras, C.
2011-03-01
FisL@bs is a network of remote and virtual laboratories for physics university education via the Internet that offers students the possibility of performing hands-on experiments in different fields of physics in two ways: simulation and real remote operation. This paper gives a detailed account of a novel way in physics in which distance learning students can gain practical experience autonomously. FisL@bs uses the same structure as AutomatL@bs, a network of virtual and remote laboratories for learning/teaching of control engineering, which has been in operation for four years. Students can experiment with the laboratories offered using an Internet connection and a Java-compatible web browser. This paper, specially intended for university educators but easily comprehensible even for undergraduate students, explains how the portal works and the hardware and software tools used to create it. In addition, it also describes two physics experiments already available: spring elasticity and the laws of reflection and refraction.
Validating Large Scale Networks Using Temporary Local Scale Networks
USDA-ARS?s Scientific Manuscript database
The USDA NRCS Soil Climate Analysis Network and NOAA Climate Reference Networks are nationwide meteorological and land surface data networks with soil moisture measurements in the top layers of soil. There is considerable interest in scaling these point measurements to larger scales for validating ...
NASA Technical Reports Server (NTRS)
Kimsey, D. B.
1978-01-01
The effect on the life cycle cost of the timing subsystem was examined, when these optional features were included in various combinations. The features included mutual control, directed control, double-ended reference links, independence of clock error measurement and correction, phase reference combining, self-organization, smoothing for link and nodal dropouts, unequal reference weightings, and a master in a mutual control network. An overall design of a microprocessor-based timing subsystem was formulated. The microprocessor (8080) implements the digital filter portion of a digital phase locked loop, as well as other control functions such as organization of the network through communication with processors at neighboring nodes.
Sezen, Figen; Albayrak, Nurhan; Özkara, Şeref; Karagöz, Alper; Alp, Alpaslan; Duyar Ağca, Filiz; İnan Süer, Asiye; Müderris, Tuba; Ceyhan, İsmail; Durmaz, Rıza; Ertek, Mustafa
2015-04-01
The most effective method for monitoring country-level drug resistance frequency and to implement the necessary control measures is the establishment of a laboratory-based surveillance system. The aim of this study was to summarize the follow up trend of the drug-resistant tuberculosis (TB) cases, determine the load of resistance and evaluate the capacities of laboratories depending on laboratory quality assurance system for the installation work of National Tuberculosis Laboratory Surveillance Network (TuLSA) which has started in Ankara in 2011. TuLSA studies was carried out under the coordination of National Tuberculosis Reference Laboratory (NRL) with the participation of TB laboratories and dispensaries. Specimens of TB patients, reported from health institutions, were followed in TB laboratories, and the epidemiological information was collected from the dispensaries. One isolate per patient with the drug susceptibility test (DST) results were sent to NRL from TB laboratories and in NRL the isolates were rechecked with the genotypical (MTBDRplus, Hain Lifescience, Germany) and phenotypical (MGIT 960, BD, USA) DST methods. Molecular epidemiological analysis were also performed by spoligotyping and MIRU/VNTR. Second-line DST was applied to the isolates resistant to rifampin. A total of 1276 patients were reported between January 1st to December 31th 2011, and 335 cases were defined as "pulmonary TB from Ankara province". The mean age of those patients was 43.4 ± 20 years, and 67.5% were male. Three hundred seventeen (94.6%) patients were identified as new cases. The average sample number obtained from pulmonary TB cases was 3.26 ± 2.88, and 229 (68.3%) of them was culture positive. DST was applied to all culture positive isolates; 90.4% (207/229) of cases were susceptible to the five drugs tested (ethambutol, isoniazid, pyrazinamide, rifampicin, streptomycin). Eight (3.5%) of the isolates were multidrug-resistant (MDR-TB), while no extensively drug-resistant strains were detected. MDR-TB is likely to occur in 63.3 times more among previously treated cases, and 73.3 times more in legal aliens. The achievement of therapy among pulmonary TB cases was 91.9%. Spoligotyping performed for 221 M.tuberculosis complex isolates, showed that all strains were clustered in nine groups. SIT 41 (105/221; 47.5%) was the most frequent spoligotype detected, and clustering rate based on MIRU-VNTR results were found as 16.3%. All of the clustered strains were sensitive while all of MDR-TB isolates showed specific MIRU-VNTR profiles. In conclusion, TuLSA studies started in Ankara in 2011 and the system is still expanding in the country. Our data obtained with TuLSA have been published as a regional surveillance data in the WHO Global Tuberculosis Report 2011, and as a national surveillance data in Global Tuberculosis Report 2012.
A Neural Network Architecture For Rapid Model Indexing In Computer Vision Systems
NASA Astrophysics Data System (ADS)
Pawlicki, Ted
1988-03-01
Models of objects stored in memory have been shown to be useful for guiding the processing of computer vision systems. A major consideration in such systems, however, is how stored models are initially accessed and indexed by the system. As the number of stored models increases, the time required to search memory for the correct model becomes high. Parallel distributed, connectionist, neural networks' have been shown to have appealing content addressable memory properties. This paper discusses an architecture for efficient storage and reference of model memories stored as stable patterns of activity in a parallel, distributed, connectionist, neural network. The emergent properties of content addressability and resistance to noise are exploited to perform indexing of the appropriate object centered model from image centered primitives. The system consists of three network modules each of which represent information relative to a different frame of reference. The model memory network is a large state space vector where fields in the vector correspond to ordered component objects and relative, object based spatial relationships between the component objects. The component assertion network represents evidence about the existence of object primitives in the input image. It establishes local frames of reference for object primitives relative to the image based frame of reference. The spatial relationship constraint network is an intermediate representation which enables the association between the object based and the image based frames of reference. This intermediate level represents information about possible object orderings and establishes relative spatial relationships from the image based information in the component assertion network below. It is also constrained by the lawful object orderings in the model memory network above. The system design is consistent with current psychological theories of recognition by component. It also seems to support Marr's notions of hierarchical indexing. (i.e. the specificity, adjunct, and parent indices) It supports the notion that multiple canonical views of an object may have to be stored in memory to enable its efficient identification. The use of variable fields in the state space vectors appears to keep the number of required nodes in the network down to a tractable number while imposing a semantic value on different areas of the state space. This semantic imposition supports an interface between the analogical aspects of neural networks and the propositional paradigms of symbolic processing.
Odhiambo, Collins; Oyaro, Boaz; Odipo, Richard; Otieno, Fredrick; Alemnji, George; Williamson, John; Zeh, Clement
2015-01-01
Important differences have been demonstrated in laboratory parameters from healthy persons in different geographical regions and populations, mostly driven by a combination of genetic, demographic, nutritional, and environmental factors. Despite this, European and North American derived laboratory reference intervals are used in African countries for patient management, clinical trial eligibility, and toxicity determination; which can result in misclassification of healthy persons as having laboratory abnormalities. An observational prospective cohort study known as the Kisumu Incidence Cohort Study (KICoS) was conducted to estimate the incidence of HIV seroconversion and identify determinants of successful recruitment and retention in preparation for an HIV vaccine/prevention trial among young adults and adolescents in western Kenya. Laboratory values generated from the KICoS were compared to published region-specific reference intervals and the 2004 NIH DAIDS toxicity tables used for the trial. About 1106 participants were screened for the KICoS between January 2007 and June 2010. Nine hundred and fifty-three participants aged 16 to 34 years, HIV-seronegative, clinically healthy, and non-pregnant were selected for this analysis. Median and 95% reference intervals were calculated for hematological and biochemistry parameters. When compared with both published region-specific reference values and the 2004 NIH DAIDS toxicity table, it was shown that the use of locally established reference intervals would have resulted in fewer participants classified as having abnormal hematological or biochemistry values compared to US derived reference intervals from DAIDS (10% classified as abnormal by local parameters vs. >40% by US DAIDS). Blood urea nitrogen was most often out of range if US based intervals were used: <10% abnormal by local intervals compared to >83% by US based reference intervals. Differences in reference intervals for hematological and biochemical parameters between western and African populations highlight importance of developing local reference intervals for clinical care and trials in Africa.
Configuration development for ROMENET
NASA Astrophysics Data System (ADS)
Rhue, Lawrence
1989-10-01
A plan prepared by RJO Enterprises and BBN Communications Corporation (BBNCC) for the design of ROMENET, a DDN-like testbed for the Rome Air Development Center (RADC) Wide Area Networks (WAN) laboratory is presented. The ROMENET is intended to provide RADC with the ability to test and evaluate the performance and vulnerability of the Defense Data Network (DDN) technologies in support of specific Major Command programs and activities at RADC. It will also support experimentation with packet switched network technologies and includes facilities to analytically evaluate the performance of the network and its associated equipment and media. In addition, ROMENET will provide a simulation vehicle for controlled interference or jamming into the media for vulnerability assessment. Through interfaces with the RADC Battle Management Laboratory (BML), ROMENET will allow the Air Force to assess the restorative and performance characteristics of the network under stressed conditions. The closed environment of ROMENET makes it ideal for creating and testing routing algorithms and network control protocols.
Hartaningsih, Nining; Wibawa, Hendra; Pudjiatmoko; Rasa, Fadjar Sumping Tjatur; Irianingsih, Sri Handayani; Dharmawan, Rama; Azhar, Muhammad; Siregar, Elly Sawitri; McGrane, James; Wong, Frank; Selleck, Paul; Allen, John; Broz, Ivano; Torchetti, Mia Kim; Dauphin, Gwenaelle; Claes, Filip; Sastraningrat, Wiryadi; Durr, Peter A
2015-06-01
Since 2006, Indonesia has used vaccination as the principal means of control of H5N1-HPAI. During this time, the virus has undergone gradual antigenic drift, which has necessitated changes in seed strains for vaccine production and associated modifications to diagnostic antigens. In order to improve the system of monitoring such viral evolution, the Government of Indonesia, with the assistance of FAO/OFFLU, has developed an innovative network whereby H5N1 isolates are antigenically and genetically characterised. This molecular surveillance network ("Influenza Virus Monitoring" or "IVM") is based on the regional network of veterinary diagnostic laboratories, and is supported by a web-based data management system ("IVM Online"). The example of the Indonesian IVM network has relevance for other countries seeking to establish laboratory networks for the molecular surveillance of avian influenza and other pathogens. Copyright © 2015 Elsevier B.V. All rights reserved.
Fuentes-Arderiu, Xavier; Alonso-Gregorio, Eduardo; Alvarez-Funes, Virtudes; Ambrós-Marigómez, Carmen; Coca-Fábregas, Lluís; Cruz-Placer, Marta; Díaz-Fernández, Julián; Pinel-Julián, María Pilar; Gutiérrez-Cecchini, Beatriz; Herrero-Bernal, Pilar; Sempere-Alcocer, Marcos; García-Caballero, Francisca; Del Mar Larrea-Ortiz-Quintana, María; La-Torre-Marcellán, Pedro; Del Señor López-Vélez, María; Mar-Medina, Carmen; Martín-Oncina, Javier; Rodríguez-Hernández, María Victoria; Romero-Sotomayor, María Victoria; Serrano-López, Cándido; Sicilia-Enríquez-de-Salamanca, Adolfo; Velasco-Romero, Ana María; Juvé-Cuxart, Santiago
2007-01-01
Clinical laboratories seeking accreditation for compliance with ISO 15189:2003 need to demonstrate that the physiological reference intervals communicated to all users of the laboratory service are appropriate for the patient population served and for the measurement systems used. In the case of immunological quantities, few articles have been published in peer-reviewed journals. A total of 21 clinical laboratories in different regions of Spain collaborated in identifying reference individuals and determining adult reference intervals for some immunological quantities measured using RD/Hitachi Modular Analytics analysers and Tina-Quant reagent systems. These immunological quantities are the mass concentrations of immunoglobulin A, immunoglobulin G, immunoglobulin M, complement C3c and complement C4 in serum. All the logistic work was carried out in co-operation with the supplier of the reagents and analysers (Roche Diagnostics España, S.L., Sant Cugat del Vallès, Catalonia, Spain). From the set of reference values obtained by each laboratory, multicentre reference limits were estimated non-parametrically. The reference intervals estimated in this study for concentrations of serum components under consideration are: complement C3c, 0.62-1.64 g/L for women and men; complement C4, 0.14-0.72 g/L for women and men; immunoglobulin A, 0.89-4.80 g/L for women and men; immunoglobulin G, 6.5-14.3 g/L for women and men; and immunoglobulin M, 0.48-3.38 g/L for women and 0.41-2.46 g/L for men.
Generation of Global Geodetic Networks for GGOS
NASA Astrophysics Data System (ADS)
MacMillan, Daniel; Pavlis, Erricos C.; Kuzmicz-Cieslak, Magda; Koenig, Daniel
2016-12-01
We simulated future networks of VLBI+SLR sites to assess their performance. The objective is to build a global network of geographically well distributed, co-located next-generation sites from each of the space geodetic techniques. The network is being designed to meet the GGOS terrestrial reference frame goals of 1 mm in accuracy and 0.1 mm/yr in stability. We simulated the next generation networks that should be available in five years and in ten years to assess the likelihood that these networks will meet the reference frame goals. Simulations were based on the expectation that 17 broadband VLBI stations will be available in five years and 27 stations in ten years. We also consider the improvement resulting from expanding the network by six additional VLBI sites to improve the global distribution of the network. In the simulations, the networks will operate continuously, but we account for station downtime for maintenance or because of bad weather. We ran SLR+VLBI combination TRF solutions, where site ties were used to connect the two networks in the same way as in combination solutions with observed data. The strengths of VLBI and SLR allows them to provide the necessary reference frame accuracy in scale, geocenter, and orientation. With the +10-year extended network operating for ten years, simulations indicate that scale, origin, and orientation accuracies will be at the level of 0.02 ppb, 0.2 mm, and 6 μas. Combining the +5-year and +10-year network realizations will provide better estimates of accuracy and estimates of stability.
Evaluation of the annual Canadian biodosimetry network intercomparisons
Wilkins, Ruth C.; Beaton-Green, Lindsay A.; Lachapelle, Sylvie; Kutzner, Barbara C.; Ferrarotto, Catherine; Chauhan, Vinita; Marro, Leonora; Livingston, Gordon K.; Boulay Greene, Hillary; Flegal, Farrah N.
2015-01-01
Abstract Purpose: To evaluate the importance of annual intercomparisons for maintaining the capacity and capabilities of a well-established biodosimetry network in conjunction with assessing efficient and effective analysis methods for emergency response. Materials and methods: Annual intercomparisons were conducted between laboratories in the Canadian National Biological Dosimetry Response Plan. Intercomparisons were performed over a six-year period and comprised of the shipment of 10–12 irradiated, blinded blood samples for analysis by each of the participating laboratories. Dose estimates were determined by each laboratory using the dicentric chromosome assay (conventional and QuickScan scoring) and where possible the cytokinesis block micronucleus (CBMN) assay. Dose estimates were returned to the lead laboratory for evaluation and comparison. Results: Individual laboratories performed comparably from year to year with only slight fluctuations in performance. Dose estimates using the dicentric chromosome assay were accurate about 80% of the time and the QuickScan method for scoring the dicentric chromosome assay was proven to reduce the time of analysis without having a significant effect on the dose estimates. Although analysis with the CBMN assay was comparable to QuickScan scoring with respect to speed, the accuracy of the dose estimates was greatly reduced. Conclusions: Annual intercomparisons are necessary to maintain a network of laboratories for emergency response biodosimetry as they evoke confidence in their capabilities. PMID:25670072
Entry Abort Determination Using Non-Adaptive Neural Networks for Mars Precision Landers
NASA Technical Reports Server (NTRS)
Graybeal, Sarah R.; Kranzusch, Kara M.
2005-01-01
The 2009 Mars Science Laboratory (MSL) will attempt the first precision landing on Mars using a modified version of the Apollo Earth entry guidance program. The guidance routine, Entry Terminal Point Controller (ETPC), commands the deployment of a supersonic parachute after converging the range to the landing target. For very dispersed cases, ETPC may not converge the range to the target and safely command parachute deployment within Mach number and dynamic pressure constraints. A full-lift up abort can save 85% of these failed trajectories while abandoning the precision landing objective. Though current MSL requirements do not call for an abort capability, an autonomous abort capability may be desired, for this mission or future Mars precision landers, to make the vehicle more robust. The application of artificial neural networks (NNs) as an abort determination technique was evaluated by personnel at the National Aeronautics and Space Administration (NASA) Johnson Space Center (JSC). In order to implement an abort, a failed trajectory needs to be recognized in real time. Abort determination is dependent upon several trajectory parameters whose relationships to vehicle survival are not well understood, and yet the lander must be trained to recognize unsafe situations. Artificial neural networks (NNs) provide a way to model these parameters and can provide MSL with the artificial intelligence necessary to independently declare an abort. Using the 2009 Mars Science Laboratory (MSL) mission as a case study, a non-adaptive NN was designed, trained and tested using Monte Carlo simulations of MSL descent and incorporated into ETPC. Neural network theory, the development history of the MSL NN, and initial testing with severe dust storm entry trajectory cases are discussed in Reference 1 and will not be repeated here. That analysis demonstrated that NNs are capable of recognizing failed descent trajectories and can significantly increase the survivability of MSL for very dispersed cases. NN testing was then broadened to evaluate fully dispersed entry trajectories. The NN correctly classified 99.7% of descent trajectories as abort or nonabort and reduced the probability of an unsafe parachute deployment by 83%. This second, broader testing phase is discussed in this paper.
Martyniuk, Christopher J
2018-04-01
Environmental science has benefited a great deal from omics-based technologies. High-throughput toxicology has defined adverse outcome pathways (AOPs), prioritized chemicals of concern, and identified novel actions of environmental chemicals. While many of these approaches are conducted under rigorous laboratory conditions, a significant challenge has been the interpretation of omics data in "real-world" exposure scenarios. Clarity in the interpretation of these data limits their use in environmental monitoring programs. In recent years, one overarching objective of many has been to address fundamental questions concerning experimental design and the robustness of data collected under the broad umbrella of environmental genomics. These questions include: (1) the likelihood that molecular profiles return to a predefined baseline level following remediation efforts, (2) how reference site selection in an urban environment influences interpretation of omics data and (3) what is the most appropriate species to monitor in the environment from an omics point of view. In addition, inter-genomics studies have been conducted to assess transcriptome reproducibility in toxicology studies. One lesson learned from inter-genomics studies is that there are core molecular networks that can be identified by multiple laboratories using the same platform. This supports the idea that "omics-networks" defined a priori may be a viable approach moving forward for evaluating environmental impacts over time. Both spatial and temporal variability in ecosystem structure is expected to influence molecular responses to environmental stressors, and it is important to recognize how these variables, as well as individual factor (i.e. sex, age, maturation), may confound interpretation of network responses to chemicals. This mini-review synthesizes the progress made towards adopting these tools into environmental monitoring and identifies future challenges to be addressed, as we move into the next era of high throughput sequencing. A conceptual framework for validating and incorporating molecular networks into environmental monitoring programs is proposed. As AOPs become more defined and their potential in environmental monitoring assessments becomes more recognized, the AOP framework may prove to be the conduit between omics and penultimate ecological responses for environmental risk assessments. Copyright © 2018 Elsevier B.V. All rights reserved.
Rahmadane, Ibnu; Certoma, Andrea F; Peck, Grantley R; Fitria, Yul; Payne, Jean; Colling, Axel; Shiell, Brian J; Beddome, Gary; Wilson, Susanne; Yu, Meng; Morrissy, Chris; Michalski, Wojtek P; Bingham, John; Gardner, Ian A; Allen, John D
2017-11-01
Rabies continues to pose a significant threat to human and animal health in regions of Indonesia. Indonesia has an extensive network of veterinary diagnostic laboratories and the 8 National laboratories are equipped to undertake diagnostic testing for rabies using the commercially-procured direct fluorescent antibody test (FAT), which is considered the reference (gold standard) test. However, many of the Indonesian Provincial diagnostic laboratories do not have a fluorescence microscope required to undertake the FAT. Instead, certain Provincial laboratories continue to screen samples using a chemical stain-based test (Seller's stain test, SST). This test has low diagnostic sensitivity, with negative SST-tested samples being forwarded to the nearest National laboratory resulting in significant delays for completion of testing and considerable additional costs. This study sought to develop a cost-effective and diagnostically-accurate immunoperoxidase antigen detection (RIAD) test for rabies that can be readily and quickly performed by the resource-constrained Provincial laboratories. This would reduce the burden on the National laboratories and allow more rapid diagnoses and implementation of post-exposure prophylaxis. The RIAD test was evaluated using brain smears fixed with acetone or formalin and its performance was validated by comparison with established rabies diagnostic tests used in Indonesia, including the SST and FAT. A proficiency testing panel was distributed between Provincial laboratories to assess the reproducibility of the test. The performance of the RIAD test was improved by using acetone fixation of brain smears rather than formalin fixation such that it was of equivalent accuracy to that of the World Organisation for Animal Health (OIE)-recommended FAT, with both tests returning median diagnostic sensitivity and specificity values of 0.989 and 0.993, respectively. The RIAD test and FAT had higher diagnostic sensitivity than the SST (median = 0.562). Proficiency testing using a panel of 6 coded samples distributed to 16 laboratories showed that the RIAD test had good reproducibility with an overall agreement of 97%. This study describes the successful development, characterisation and use of a novel RIAD test and its fitness for purpose as a screening test for use in provincial Indonesian veterinary laboratories.
Trusted Network Interpretation of the Trusted Computer System Evaluation Criteria. Version 1.
1987-07-01
for Secure Computer Systema, MTR-3153, The MITRE Corporation, Bedford, MA, June 1975. 1 See, for example, M. D. Abrams and H. J. Podell , Tutorial...References References Abrams, M. D. and H. J. Podell , Tutorial: Computer and Network Security, IEEE Com- puter Society Press, 1987. Addendum to the
A Wireless Communications Laboratory on Cellular Network Planning
ERIC Educational Resources Information Center
Dawy, Z.; Husseini, A.; Yaacoub, E.; Al-Kanj, L.
2010-01-01
The field of radio network planning and optimization (RNPO) is central for wireless cellular network design, deployment, and enhancement. Wireless cellular operators invest huge sums of capital on deploying, launching, and maintaining their networks in order to ensure competitive performance and high user satisfaction. This work presents a lab…
ERIC Educational Resources Information Center
Tennant, Roy
2005-01-01
In the article, the author talks about the benefits of grid networks. In speaking of grid networks the author is referring to both networks of computers and networks of humans connected together in a grid topology. Examples are provided of how grid networks are beneficial today and the ways in which they have been used.
Moreno, Megan A.; Swanson, Michael J.; Royer, Heather; Roberts, Linda J.
2011-01-01
Study Objective Sexual reference display on a social networking web site (SNS) is associated with self-reported sexual intention; females are more likely to display sexually explicit content on SNSs. The purpose of this study was to investigate male college students' views towards sexual references displayed on publicly available SNSs by females. Design Focus groups Setting One large state university Participants Male college students age 18–23 Interventions All tape recorded data was fully transcribed, then discussed to determine thematic consensus. Main Outcome Measures A trained male facilitator asked participants about views on sexual references displayed on SNSs by female peers and showed examples of sexual references from female's SNS profiles to facilitate discussion. Results A total of 28 heterosexual male participants participated in 7 focus groups. Nearly all participants reported using Facebook to evaluate potential female partners. Three themes emerged from our data. First, participants reported that displays of sexual references on social networking web sites increased sexual expectations. Second, sexual reference display decreased interest in pursuing a dating relationship. Third, SNS data was acknowledged as imperfect but valuable. Conclusion Females who display sexual references on publicly available SNS profiles may be influencing potential partners' sexual expectations and dating intentions. Future research should examine females' motivations and beliefs about displaying such references, and educate women about the potential impact of these sexual displays. PMID:21190872
Moreno, Megan A; Swanson, Michael J; Royer, Heather; Roberts, Linda J
2011-04-01
Sexual reference display on a social networking web site (SNS) is associated with self-reported sexual intention; females are more likely to display sexually explicit content on SNSs. The purpose of this study was to investigate male college students' views towards sexual references displayed on publicly available SNSs by females. Focus groups. One large state university. Male college students age 18-23. All tape recorded discussion was fully transcribed, then discussed to determine thematic consensus. A trained male facilitator asked participants about views on sexual references displayed on SNSs by female peers and showed examples of sexual references from female's SNS profiles to facilitate discussion. A total of 28 heterosexual male participants participated in seven focus groups. Nearly all participants reported using Facebook to evaluate potential female partners. Three themes emerged from our data. First, participants reported that displays of sexual references on social networking web sites increased sexual expectations. Second, sexual reference display decreased interest in pursuing a dating relationship. Third, SNS data was acknowledged as imperfect but valuable. Females who display sexual references on publicly available SNS profiles may be influencing potential partners' sexual expectations and dating intentions. Future research should examine females' motivations and beliefs about displaying such references and educate women about the potential impact of these sexual displays. Copyright © 2011 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.
Predictive value and efficiency of laboratory testing.
Galen, R S
1980-11-01
Literature on determining reference values and reference intervals on "normal" or "healthy" individuals is abundant. It is impossible, however, to evaluate a data set of reference values and select a suitable reference interval that will be meaningful for the practice of medicine. The reference interval, no matter how derived statistically, tells us nothing about disease. This is the main reason the concepts of "normal values" have failed us and why "reference values" will prove similarly disappointing. By studying these same constituents in a variety of disease states as well, it will be possible to select "referent values" that will make the test procedure meaningful for diagnostic purposes. In order to obtain meaningful referent values for predicting disease, it is necessary to study not only the "healthy" reference population, but patients with the disease in question, and patients who are free of the disease in question but who have other diseases. Studies of this type are not frequently found for laboratory tests that are in common use today.
van Asten, Liselotte; van der Lubben, Mariken; van den Wijngaard, Cees; van Pelt, Wilfrid; Verheij, Robert; Jacobi, Andre; Overduin, Pieter; Meijer, Adam; Luijt, Dirk; Claas, Eric; Hermans, Mirjam; Melchers, Willem; Rossen, John; Schuurman, Rob; Wolffs, Petra; Boucher, Charles; Bouchier, Charles; Schirm, Jurjen; Kroes, Louis; Leenders, Sander; Galama, Joep; Peeters, Marcel; van Loon, Anton; Stobberingh, Ellen; Schutten, Martin; Koopmans, Marion
2009-07-01
Experience with a highly pathogenic avian influenza outbreak in the Netherlands (2003) illustrated that the diagnostic demand for respiratory viruses at different biosafety levels (including BSL3), can increase unexpectedly and dramatically. We describe the measures taken since, aimed at strengthening national laboratory surge capacity and improving preparedness for dealing with diagnostic demand during outbreaks of (emerging) respiratory virus infections, including pandemic influenza virus. Academic and peripheral medical-microbiological laboratories collaborated to determine minimal laboratory requirements for the identification of viruses in the early stages of a pandemic or a large outbreak of avian influenza virus. Next, an enhanced collaborative national network of outbreak assistance laboratories (OAL) was set up. An inventory was made of the maximum diagnostic throughput that this network can deliver in a period of intensified demand. For an estimate of the potential magnitude of this surge demand, historical counts were calculated from hospital- and physician-based registries of patients presenting with respiratory symptoms. Number of respiratory physician-visits ranged from 140,000 to 615,000 per month and hospitalizations ranged from 3000 to 11,500 per month. The established OAL-network provides rapid diagnostic response with agreed quality requirements and a maximum throughput capacity of 1275 samples/day (38,000 per month), assuming other routine diagnostic work needs to be maintained. Thus surge demand for diagnostics for hospitalized cases (if not distinguishable from other respiratory illness) could be handled by the OAL network. Assessing etiology of community acquired acute respiratory infection however, may rapidly exceed the capacity of the network. Therefore algorithms are needed for triaging for laboratory diagnostics; currently this is not addressed in pandemic preparedness plans.
Comparison of Data Quality of NOAA's ISIS and SURFRAD Networks to NREL's SRRL-BMS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anderberg, M.; Sengupta, M.
2014-11-01
This report provides analyses of broadband solar radiometric data quality for the National Oceanic and Atmospheric Administration's Integrated Surface Irradiance Study and Surface Radiation Budget Network (SURFRAD) solar measurement networks. The data quality of these networks is compared to that of the National Renewable Energy Laboratory's Solar Radiation Research Laboratory Baseline Measurement System (SRRL-BMS) native data resolutions and hourly averages of the data from the years 2002 through 2013. This report describes the solar radiometric data quality testing and flagging procedures and the method used to determine and tabulate data quality statistics. Monthly data quality statistics for each network weremore » plotted by year against the statistics for the SRRL-BMS. Some of the plots are presented in the body of the report, but most are in the appendix. These plots indicate that the overall solar radiometric data quality of the SURFRAD network is superior to that of the Integrated Surface Irradiance Study network and can be comparable to SRRL-BMS.« less
NASA Astrophysics Data System (ADS)
Schumann, Dorothea; Sibbens, Goedele; Stolarz, Anna; Eberhardt, Klaus; Lommel, Bettina; Stodel, Christelle
2018-05-01
A wide number of research fields in the nuclear sector requires high-quality and well-characterized samples and targets. Currently, only a few laboratories own or have access to the equipment allowing fulfilling such demands. Coordination of activities and sharing resources is therefore mandatory to meet the increasing needs. This very urgent issue has now been addressed by six European target laboratories with an initiative called ANITA (Advanced Network for Isotope and TArget laboratories). The global aim of ANITA is to establish an overarching research infrastructure service for isotope and target production and develop a tight cooperation between the target laboratories in Europe in order to transfer the knowledge and improve the production techniques of well-characterized samples and targets. Moreover, the interaction of the target producers with the users shall be encouraged and intensified to deliver tailor-made targets best-suited to the envisaged experiments. For the realization of this ambitious goal, efforts within the European Commission and strong support by the target-using communities will be necessary. In particular, an appropriate funding instrument has to be found and applied, enabling ANITA to develop from an initiative employed by the interested parties to a real coordination platform.
Ravichandran, Ramamoorthy; Binukumar, Johnson Pichy; Davis, Cheriyathmanjiyil Antony
2013-01-01
The measured dose in water at reference point in phantom is a primary parameter for planning the treatment monitor units (MU); both in conventional and intensity modulated/image guided treatments. Traceability of dose accuracy therefore still depends mainly on the calibration factor of the ion chamber/dosimeter provided by the accredited Secondary Standard Dosimetry Laboratories (SSDLs), under International Atomic Energy Agency (IAEA) network of laboratories. The data related to Nd,water calibrations, thermoluminescent dosimetry (TLD) postal dose validation, inter-comparison of different dosimeter/electrometers, and validity of Nd,water calibrations obtained from different calibration laboratories were analyzed to find out the extent of accuracy achievable. Nd,w factors in Gray/Coulomb calibrated at IBA, GmBH, Germany showed a mean variation of about 0.2% increase per year in three Farmer chambers, in three subsequent calibrations. Another ion chamber calibrated in different accredited laboratory (PTW, Germany) showed consistent Nd,w for 9 years period. The Strontium-90 beta check source response indicated long-term stability of the ion chambers within 1% for three chambers. Results of IAEA postal TL “dose intercomparison” for three photon beams, 6 MV (two) and 15 MV (one), agreed well within our reported doses, with mean deviation of 0.03% (SD 0.87%) (n = 9). All the chamber/electrometer calibrated by a single SSDL realized absorbed doses in water within 0.13% standard deviations. However, about 1-2% differences in absorbed dose estimates observed when dosimeters calibrated from different calibration laboratories are compared in solid phantoms. Our data therefore imply that the dosimetry level maintained for clinical use of linear accelerator photon beams are within recommended levels of accuracy, and uncertainties are within reported values. PMID:24672156
An overview on development of neural network technology
NASA Technical Reports Server (NTRS)
Lin, Chun-Shin
1993-01-01
The study has been to obtain a bird's-eye view of the current neural network technology and the neural network research activities in NASA. The purpose was two fold. One was to provide a reference document for NASA researchers who want to apply neural network techniques to solve their problems. Another one was to report out survey results regarding NASA research activities and provide a view on what NASA is doing, what potential difficulty exists and what NASA can/should do. In a ten week study period, we interviewed ten neural network researchers in the Langley Research Center and sent out 36 survey forms to researchers at the Johnson Space Center, Lewis Research Center, Ames Research Center and Jet Propulsion Laboratory. We also sent out 60 similar forms to educators and corporation researchers to collect general opinions regarding this field. Twenty-eight survey forms, 11 from NASA researchers and 17 from outside, were returned. Survey results were reported in our final report. In the final report, we first provided an overview on the neural network technology. We reviewed ten neural network structures, discussed the applications in five major areas, and compared the analog, digital and hybrid electronic implementation of neural networks. In the second part, we summarized known NASA neural network research studies and reported the results of the questionnaire survey. Survey results show that most studies are still in the development and feasibility study stage. We compared the techniques, application areas, researchers' opinions on this technology, and many aspects between NASA and non-NASA groups. We also summarized their opinions on difficulties encountered. Applications are considered the top research priority by most researchers. Hardware development and learning algorithm improvement are the next. The lack of financial and management support is among the difficulties in research study. All researchers agree that the use of neural networks could result in cost saving. Fault tolerance has been claimed as one important feature of neural computing. However, the survey indicates that very few studies address this issue. Fault tolerance is important in space mission and aircraft control. We believe that it is worthy for NASA to devote more efforts into the utilization of this feature.
Viability of using energy storage for frequency regulation on power grid
NASA Astrophysics Data System (ADS)
Lim, Y. S.; Hau, L. C.; Loh, K. Y.; Lim, K. Y.; Lyons, P. F.; Taylor, P. C.
2018-05-01
This project is about the development and integration of a real-time network simulator in the laboratory using hardware in the loop (HIL) for the purpose of frequency regulation. Frequency regulation is done using the energy storage system (ESS) and a real-time network test bed developed in the smart energy laboratory in Newcastle University. An IEEE Test System was built in the OPAL-RT network simulator to mimic the power grid with renewable energy sources. The study demonstrates the viability of using an ESS to regulate the frequency under an increased penetration of renewable energy sources.
NASA Technical Reports Server (NTRS)
Svoboda, James S.; Kachmar, Brian A.
1993-01-01
The design and performance of a rain fade simulation/counteraction system on a laboratory simulated 30/20 GHz, time division multiple access (TDMA) satellite communications testbed is evaluated. Severe rain attenuation of electromagnetic radiation at 30/20 GHz occurs due to the carrier wavelength approaching the water droplet size. Rain in the downlink path lowers the signal power present at the receiver, resulting in a higher number of bit errors induced in the digital ground terminal. The laboratory simulation performed at NASA Lewis Research Center uses a programmable PIN diode attenuator to simulate 20 GHz satellite downlink geographic rain fade profiles. A computer based network control system monitors the downlink power and informs the network of any power threshold violations, which then prompts the network to issue commands that temporarily increase the gain of the satellite based traveling wave tube (TWT) amplifier. After the rain subsides, the network returns the TWT to the normal energy conserving power mode. Bit error rate (BER) data taken at the receiving ground terminal serves as a measure of the severity of rain degradation, and also evaluates the extent to which the network can improve the faded channel.
[Study of quality of a branch laboratory--an opinion of a laboratory manager].
Yazawa, Naoyuki
2006-11-01
At the stage of establishing a branch laboratory, quality evaluation is extremely difficult. Even the results of a control survey by the headquarters of the branch laboratory are unhelpful. For a clinical laboratory, the most important function is to provide reliable data all the time, and to maintain the reliability of clinical doctors with informed responses. We mostly refer to control surveys and daily quality control data to evaluate a clinical laboratory, but we rarely check its fundamental abilities, such as planning events, preserving statistical data about the standard range, using the right method for quality control and others. This is generally disregarded and it is taken for granted that they will be correct the first time. From my six years of experience working with X's branch laboratory, I realized that there might be some relation between the quality of a branch laboratory and the fundamental abilities of the company itself. I would never argue that all branch laboratories are ineffective, but they should be conscious of fundamental activities. The referring laboratory, not the referral laboratory, should be responsible for ensuring that the referral laboratory's examination results and findings are correct.
Pyranometer offsets triggered by ambient meteorology: insights from laboratory and field experiments
NASA Astrophysics Data System (ADS)
Oswald, Sandro M.; Pietsch, Helga; Baumgartner, Dietmar J.; Weihs, Philipp; Rieder, Harald E.
2017-03-01
This study investigates the effects of ambient meteorology on the accuracy of radiation (R) measurements performed with pyranometers contained in various heating and ventilation systems (HV-systems). It focuses particularly on instrument offsets observed following precipitation events. To quantify pyranometer responses to precipitation, a series of controlled laboratory experiments as well as two targeted field campaigns were performed in 2016. The results indicate that precipitation (as simulated by spray tests or observed under ambient conditions) significantly affects the thermal environment of the instruments and thus their stability. Statistical analyses of laboratory experiments showed that precipitation triggers zero offsets of -4 W m-2 or more, independent of the HV-system. Similar offsets were observed in field experiments under ambient environmental conditions, indicating a clear exceedance of BSRN (Baseline Surface Radiation Network) targets following precipitation events. All pyranometers required substantial time to return to their initial signal states after the simulated precipitation events. Therefore, for BSRN-class measurements, the recommendation would be to flag the radiation measurements during a natural precipitation event and 90 min after it in nighttime conditions. Further daytime experiments show pyranometer offsets of 50 W m-2 or more in comparison to the reference system. As they show a substantially faster recovery, the recommendation would be to flag the radiation measurements within a natural precipitation event and 10 min after it in daytime conditions.
Søeby, Karen; Jensen, Peter Bjødstrup; Werge, Thomas; Sørensen, Steen
2015-09-01
The knowledge of physiological fluctuation and variation of even commonly used biochemical quantities in extreme age groups and during development is sparse. This challenges the clinical interpretation and utility of laboratory tests in these age groups. To explore the utility of hospital laboratory data as a source of information, we analyzed enzymatic plasma creatinine as a model analyte in two large pediatric hospital samples. Plasma creatinine measurements from 9700 children aged 0-18 years were obtained from hospital laboratory databases and partitioned into high-resolution gender- and age-groups. Normal probability plots were used to deduce parameters of the normal distributions from healthy creatinine values in the mixed hospital datasets. Furthermore, temporal trajectories were generated from repeated measurements to examine developmental patterns in periods of changing creatinine levels. Creatinine shows great age dependence from birth throughout childhood. We computed and replicated 95% reference intervals in narrow gender and age bins and showed them to be comparable to those determined in healthy population studies. We identified pronounced transitions in creatinine levels at different time points after birth and around the early teens, which challenges the establishment and usefulness of reference intervals in those age groups. The study documents that hospital laboratory data may inform on the developmental aspects of creatinine, on periods with pronounced heterogeneity and valid reference intervals. Furthermore, part of the heterogeneity in creatinine distribution is likely due to differences in biological and chronological age of children and should be considered when using age-specific reference intervals.
Online Grading of Calculations in General Chemistry Laboratory Write-Ups
ERIC Educational Resources Information Center
Silva, Alexsandra; Gonzales, Robert; Brennan, Daniel P.
2010-01-01
In the past, there were frequently complaints about the grading of laboratory reports in our laboratory chemistry courses. This article discussed the implementation of an online submission of laboratory acquired data using LON-CAPA (The Learning Online Network with Computer-Assisted Personalized Approach), which is an open source management and…
Jean Louis, Frantz; Buteau, Josiane; Boncy, Jacques; Anselme, Renette; Stanislas, Magalie; Nagel, Mary C; Juin, Stanley; Charles, Macarthur; Burris, Robert; Antoine, Eva; Yang, Chunfu; Kalou, Mireille; Vertefeuille, John; Marston, Barbara J; Lowrance, David W; Deyde, Varough
2017-10-01
Before the 2010 devastating earthquake and cholera outbreak, Haiti's public health laboratory systems were weak and services were limited. There was no national laboratory strategic plan and only minimal coordination across the laboratory network. Laboratory capacity was further weakened by the destruction of over 25 laboratories and testing sites at the departmental and peripheral levels and the loss of life among the laboratory health-care workers. However, since 2010, tremendous progress has been made in building stronger laboratory infrastructure and training a qualified public health laboratory workforce across the country, allowing for decentralization of access to quality-assured services. Major achievements include development and implementation of a national laboratory strategic plan with a formalized and strengthened laboratory network; introduction of automation of testing to ensure better quality of results and diversify the menu of tests to effectively respond to outbreaks; expansion of molecular testing for tuberculosis, human immunodeficiency virus, malaria, diarrheal and respiratory diseases; establishment of laboratory-based surveillance of epidemic-prone diseases; and improvement of the overall quality of testing. Nonetheless, the progress and gains made remain fragile and require the full ownership and continuous investment from the Haitian government to sustain these successes and achievements.
Jean Louis, Frantz; Buteau, Josiane; Boncy, Jacques; Anselme, Renette; Stanislas, Magalie; Nagel, Mary C.; Juin, Stanley; Charles, Macarthur; Burris, Robert; Antoine, Eva; Yang, Chunfu; Kalou, Mireille; Vertefeuille, John; Marston, Barbara J.; Lowrance, David W.; Deyde, Varough
2017-01-01
Abstract. Before the 2010 devastating earthquake and cholera outbreak, Haiti’s public health laboratory systems were weak and services were limited. There was no national laboratory strategic plan and only minimal coordination across the laboratory network. Laboratory capacity was further weakened by the destruction of over 25 laboratories and testing sites at the departmental and peripheral levels and the loss of life among the laboratory health-care workers. However, since 2010, tremendous progress has been made in building stronger laboratory infrastructure and training a qualified public health laboratory workforce across the country, allowing for decentralization of access to quality-assured services. Major achievements include development and implementation of a national laboratory strategic plan with a formalized and strengthened laboratory network; introduction of automation of testing to ensure better quality of results and diversify the menu of tests to effectively respond to outbreaks; expansion of molecular testing for tuberculosis, human immunodeficiency virus, malaria, diarrheal and respiratory diseases; establishment of laboratory-based surveillance of epidemic-prone diseases; and improvement of the overall quality of testing. Nonetheless, the progress and gains made remain fragile and require the full ownership and continuous investment from the Haitian government to sustain these successes and achievements. PMID:29064354
15 CFR 200.104 - Standard reference materials.
Code of Federal Regulations, 2014 CFR
2014-01-01
... the NIST National Measurement Laboratory administers a program to provide many types of well... be readily referred to a common base. NIST SP 260 is a catalog of Standard Reference Materials available from NIST. ...
15 CFR 200.104 - Standard reference materials.
Code of Federal Regulations, 2013 CFR
2013-01-01
... the NIST National Measurement Laboratory administers a program to provide many types of well... be readily referred to a common base. NIST SP 260 is a catalog of Standard Reference Materials available from NIST. ...
15 CFR 200.104 - Standard reference materials.
Code of Federal Regulations, 2011 CFR
2011-01-01
... the NIST National Measurement Laboratory administers a program to provide many types of well... be readily referred to a common base. NIST SP 260 is a catalog of Standard Reference Materials available from NIST. ...
15 CFR 200.104 - Standard reference materials.
Code of Federal Regulations, 2010 CFR
2010-01-01
... the NIST National Measurement Laboratory administers a program to provide many types of well... be readily referred to a common base. NIST SP 260 is a catalog of Standard Reference Materials available from NIST. ...
15 CFR 200.104 - Standard reference materials.
Code of Federal Regulations, 2012 CFR
2012-01-01
... the NIST National Measurement Laboratory administers a program to provide many types of well... be readily referred to a common base. NIST SP 260 is a catalog of Standard Reference Materials available from NIST. ...
2018-03-19
ethnographic research (Anderson 2009). Ethnographic research stresses interacting with system users in their natural environment while observing and...network integration evaluation (NIE) 13.2: observations on cognitive load in mission command. Aberdeen Proving Ground (MD): Army Research Laboratory...ARL-TR-8322 ● MAR 2018 US Army Research Laboratory The New Equipment is Here, Now Comes the Hard Part: Cognitive and
Measuring Networking as an Outcome Variable in Undergraduate Research Experiences
Hanauer, David I.; Hatfull, Graham
2015-01-01
The aim of this paper is to propose, present, and validate a simple survey instrument to measure student conversational networking. The tool consists of five items that cover personal and professional social networks, and its basic principle is the self-reporting of degrees of conversation, with a range of specific discussion partners. The networking instrument was validated in three studies. The basic psychometric characteristics of the scales were established by conducting a factor analysis and evaluating internal consistency using Cronbach’s alpha. The second study used a known-groups comparison and involved comparing outcomes for networking scales between two different undergraduate laboratory courses (one involving a specific effort to enhance networking). The final study looked at potential relationships between specific networking items and the established psychosocial variable of project ownership through a series of binary logistic regressions. Overall, the data from the three studies indicate that the networking scales have high internal consistency (α = 0.88), consist of a unitary dimension, can significantly differentiate between research experiences with low and high networking designs, and are related to project ownership scales. The ramifications of the networking instrument for student retention, the enhancement of public scientific literacy, and the differentiation of laboratory courses are discussed. PMID:26538387
Souza, Marcos Antônio de; Salvalaio, Dalva
2010-10-01
to analyze the cost of a self-owned network maintained by a Brazilian health insurance provider as compared to the price charged by accredited service providers, so as to identify whether or not the self-owned network is economically advantageous. for this exploratory study, the company's management reports were reviewed. The cost associated with the self-owned network was calculated based on medical and dental office visits and diagnostic/laboratory tests performed at one of the company's most representative facilities. The costs associated with third parties were derived from price tables used by the accredited network for the same services analyzed in the self-owned network. The full-cost method was used for cost quantification. Costs are presented as absolute values (in R$) and percent comparisons between self-owned network costs versus accredited network costs. overall, the self-owned network was advantageous for medical and dental consultations as well as diagnostic and laboratory tests. Pediatric and labor medicine consultations and x-rays were less costly in the accredited network. the choice of verticalization has economic advantages for the health care insurance operator in comparison with services provided by third parties.
web-based interactive data processing: application to stable isotope metrology.
Verkouteren, R M; Lee, J N
2001-08-01
To address a fundamental need in stable isotope metrology, the National Institute of Standards and Technology (NIST) has established a web-based interactive data-processing system accessible through a common gateway interface (CGI) program on the internet site http://www. nist.gov/widps-co2. This is the first application of a web-based tool that improves the measurement traceability afforded by a series of NIST standard materials. Specifically, this tool promotes the proper usage of isotope reference materials (RMs) and improves the quality of reported data from extensive measurement networks. Through the International Atomic Energy Agency (IAEA), we have defined standard procedures for stable isotope measurement and data-processing, and have determined and applied consistent reference values for selected NIST and IAEA isotope RMs. Measurement data of samples and RMs are entered into specified fields on the web-based form. These data are submitted through the CGI program on a NIST Web server, where appropriate calculations are performed and results returned to the client. Several international laboratories have independently verified the accuracy of the procedures and algorithm for measurements of naturally occurring carbon-13 and oxygen-18 abundances and slightly enriched compositions up to approximately 150% relative to natural abundances. To conserve the use of the NIST RMs, users may determine value assignments for a secondary standard to be used in routine analysis. Users may also wish to validate proprietary algorithms embedded in their laboratory instrumentation, or specify the values of fundamental variables that are usually fixed in reduction algorithms to see the effect on the calculations. The results returned from the web-based tool are limited in quality only by the measurements themselves, and further value may be realized through the normalization function. When combined with stringent measurement protocols, two- to threefold improvements have been realized in the reproducibility of carbon-13 and oxygen-18 determinations across laboratories.
NASA Astrophysics Data System (ADS)
Vasanelli, E.; Calia, A.; Aiello, M. A.; Sileo, M.; Leucci, G.
2012-04-01
Restoration works of the historical-architectural built heritage move from the typological and mechanical qualification of the buildings. Minimum destructive impact is required in preliminary diagnostic studies for the interventions, as it is possible. The use of the undestructive and non-invasive diagnostic techniques has always advantages in the activities on pre-existing buildings, in terms of sustainability; moreover, it is a need with respect to the conservation constraints when we act on the historical-architectural heritage. This work deals with destructive and non-destructive tests for the mechanical characterisation of some traditional soft stones, used as building materials in the Southern Italy; it is a part of a larger activity devoted to set up non-invasive diagnostic procedures for the mechanical analysis and qualification of ancient masonries. The laboratory experimental activity is based on the use of mechanical compressive tests, ultrasonic and Schmidt-Hammer tests, and the research of correlation between the results obtained by these crossed tests. It is aimed to verify the effectiveness and/or to point out critical aspects and limits of the above mentioned non-destructive tests - already applied in the field of the concrete and compact stones - with reference to the characterisation of the soft stones. The research of correlations between the results of destructive and non destructive tests has the final aim to reduce the use of destructive analyses on the masonries, by acquiring substitutive information derivable from performing NDT in laboratory, as well as in situ conditions. Finally, data gathered by the mechanical characterisation give reference values for the evaluation and control of the effectiveness of restoration interventions and their monitoring. This activity is carried out in an interdisciplinary way within the AITECH network (Applied Innovation Technologies for Diagnosis and Conservation of Built Heritage), a regional research laboratory infrastructure (Apulian region, Southern Italy) funded within the FSE and FESR programs and realised by the contribution of the Italian CNR and Salento University.
Towards an International Culture: Gen Y Students and SNS?
ERIC Educational Resources Information Center
Lichy, Jessica
2012-01-01
This article reports the findings of a small-scale investigation into the Internet user behaviour of generation Y (Gen Y) students, with particular reference to social networking sites. The study adds to the literature on cross-cultural Internet user behaviour with specific reference to Gen Y and social networking. It compares how a cohort of…
Patrick, David M; Miller, Ruth R; Gardy, Jennifer L; Parker, Shoshana M; Morshed, Muhammad G; Steiner, Theodore S; Singer, Joel; Shojania, Kam; Tang, Patrick
2015-10-01
A subset of patients reporting a diagnosis of Lyme disease can be described as having alternatively diagnosed chronic Lyme syndrome (ADCLS), in which diagnosis is based on laboratory results from a nonreference Lyme specialty laboratory using in-house criteria. Patients with ADCLS report symptoms similar to those reported by patients with chronic fatigue syndrome (CFS). We performed a case-control study comparing patients with ADCLS and CFS to each other and to both healthy controls and controls with systemic lupus erythematosus (SLE). Subjects completed a history, physical exam, screening laboratory tests, 7 functional scales, reference serology for Lyme disease using Centers for Disease Control and Prevention criteria, reference serology for other tick-associated pathogens, and cytokine expression studies. The study enrolled 13 patients with ADCLS (12 of whom were diagnosed by 1 alternative US laboratory), 25 patients with CFS, 25 matched healthy controls, and 11 SLE controls. Baseline clinical data and functional scales indicate significant disability among ADCLS and CFS patients and many important differences between these groups and controls, but no significant differences between each other. No ADCLS patient was confirmed as having positive Lyme serology by reference laboratory testing, and there was no difference in distribution of positive serology for other tick-transmitted pathogens or cytokine expression across the groups. In British Columbia, a setting with low Lyme disease incidence, ADCLS patients have a similar phenotype to that of CFS patients. Disagreement between alternative and reference laboratory Lyme testing results in this setting is most likely explained by false-positive results from the alternative laboratory. © The Author 2015. Published by Oxford University Press on behalf of the Infectious Diseases Society of America. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Pencil-and-Paper Neural Networks: An Undergraduate Laboratory Exercise in Computational Neuroscience
Crisp, Kevin M.; Sutter, Ellen N.; Westerberg, Jacob A.
2015-01-01
Although it has been more than 70 years since McCulloch and Pitts published their seminal work on artificial neural networks, such models remain primarily in the domain of computer science departments in undergraduate education. This is unfortunate, as simple network models offer undergraduate students a much-needed bridge between cellular neurobiology and processes governing thought and behavior. Here, we present a very simple laboratory exercise in which students constructed, trained and tested artificial neural networks by hand on paper. They explored a variety of concepts, including pattern recognition, pattern completion, noise elimination and stimulus ambiguity. Learning gains were evident in changes in the use of language when writing about information processing in the brain. PMID:26557791
A wireless sensor enabled by wireless power.
Lee, Da-Sheng; Liu, Yu-Hong; Lin, Chii-Ruey
2012-11-22
Through harvesting energy by wireless charging and delivering data by wireless communication, this study proposes the concept of a wireless sensor enabled by wireless power (WPWS) and reports the fabrication of a prototype for functional tests. One WPWS node consists of wireless power module and sensor module with different chip-type sensors. Its main feature is the dual antenna structure. Following RFID system architecture, a power harvesting antenna was designed to gather power from a standard reader working in the 915 MHz band. Referring to the Modbus protocol, the other wireless communication antenna was integrated on a node to send sensor data in parallel. The dual antenna structure integrates both the advantages of an RFID system and a wireless sensor. Using a standard UHF RFID reader, WPWS can be enabled in a distributed area with a diameter up to 4 m. Working status is similar to that of a passive tag, except that a tag can only be queried statically, while the WPWS can send dynamic data from the sensors. The function is the same as a wireless sensor node. Different WPWSs equipped with temperature and humidity, optical and airflow velocity sensors are tested in this study. All sensors can send back detection data within 8 s. The accuracy is within 8% deviation compared with laboratory equipment. A wireless sensor network enabled by wireless power should be a totally wireless sensor network using WPWS. However, distributed WPWSs only can form a star topology, the simplest topology for constructing a sensor network. Because of shielding effects, it is difficult to apply other complex topologies. Despite this limitation, WPWS still can be used to extend sensor network applications in hazardous environments. Further research is needed to improve WPWS to realize a totally wireless sensor network.
A Wireless Sensor Enabled by Wireless Power
Lee, Da-Sheng; Liu, Yu-Hong; Lin, Chii-Ruey
2012-01-01
Through harvesting energy by wireless charging and delivering data by wireless communication, this study proposes the concept of a wireless sensor enabled by wireless power (WPWS) and reports the fabrication of a prototype for functional tests. One WPWS node consists of wireless power module and sensor module with different chip-type sensors. Its main feature is the dual antenna structure. Following RFID system architecture, a power harvesting antenna was designed to gather power from a standard reader working in the 915 MHz band. Referring to the Modbus protocol, the other wireless communication antenna was integrated on a node to send sensor data in parallel. The dual antenna structure integrates both the advantages of an RFID system and a wireless sensor. Using a standard UHF RFID reader, WPWS can be enabled in a distributed area with a diameter up to 4 m. Working status is similar to that of a passive tag, except that a tag can only be queried statically, while the WPWS can send dynamic data from the sensors. The function is the same as a wireless sensor node. Different WPWSs equipped with temperature and humidity, optical and airflow velocity sensors are tested in this study. All sensors can send back detection data within 8 s. The accuracy is within 8% deviation compared with laboratory equipment. A wireless sensor network enabled by wireless power should be a totally wireless sensor network using WPWS. However, distributed WPWSs only can form a star topology, the simplest topology for constructing a sensor network. Because of shielding effects, it is difficult to apply other complex topologies. Despite this limitation, WPWS still can be used to extend sensor network applications in hazardous environments. Further research is needed to improve WPWS to realize a totally wireless sensor network. PMID:23443370
Smith, Alexandra; Roman, Eve; Howell, Debra; Jones, Richard; Patmore, Russell; Jack, Andrew
2010-01-01
The Haematological Malignancy Research Network (HMRN) was established in 2004 to provide robust generalizable data to inform clinical practice and research. It comprises an ongoing population-based cohort of patients newly diagnosed by a single integrated haematopathology laboratory in two adjacent UK Cancer Networks (population 3·6 million). With an emphasis on primary-source data, prognostic factors, sequential treatment/response history, and socio-demographic details are recorded to clinical trial standards. Data on 8131 patients diagnosed over the 4 years 2004–08 are examined here using the latest World Health Organization classification. HMRN captures all diagnoses (adult and paediatric) and the diagnostic age ranged from 4 weeks to 99 years (median 70·4 years). In line with published estimates, first-line clinical trial entry varied widely by disease subtype and age, falling from 59·5% in those aged <15 years to 1·9% in those aged over 75 years – underscoring the need for contextual population-based treatment and response data of the type collected by HMRN. The critical importance of incorporating molecular and prognostic markers into comparative survival analyses is illustrated with reference to diffuse-large B-cell lymphoma, acute myeloid leukaemia and myeloma. With respect to aetiology, several descriptive factors are highlighted and discussed, including the unexplained male predominance evident for most subtypes across all ages. PMID:19958356
Optical-Fiber Power Meter Comparison between NIST and KRISS.
Vayshenker, I; Kim, S K; Hong, K; Lee, D-H; Livigni, D J; Li, X; Lehman, J H
2012-01-01
We describe the results of a comparison of reference standards between the National Institute of Standards and Technology (NIST-USA) and Korea Research Institute of Standards and Science (KRISS-R.O. Korea) for optical fiber-based power measurements at wavelengths of 1302 nm and 1546 nm. We compare the laboratories' reference standards by means of a temperature-controlled optical trap detector. Measurement results showed the largest difference of less than 2.5 parts in 10(3), which is within the combined standard (k=1) uncertainty for the two laboratories' reference standards.
Optical-Fiber Power Meter Comparison Between NIST and PTB.
Vayshenker, I; Haars, H; Li, X; Lehman, J H; Livigni, D J
2003-01-01
We describe the results of a comparison of reference standards between the National Institute of Standards and Technology (NIST-USA) and Physikalisch-Technische Bundesanstalt (PTB-Germany) at nominal wavelengths of 1300 nm and 1550 nm using an optical-fiber cable. Both laboratories used thermal detectors as reference standards. A novel temperature-controlled, optical-trap detector was used as a transfer standard to compare two reference standards. Measurement results showed differences of less than 1.5 × 10(-3), which is within the combined uncertainty for both laboratories.
Environmental Response Laboratory Network activities include the All Hazard Receipt Facility and Screening Protocol, standardizing chemical methods, Chemical Warfare Agent Fixed Laboratory Pilot Project, microbial efforts, and WLA response plan.
NASA Astrophysics Data System (ADS)
Guillevic, Myriam; Vollmer, Martin K.; Wyss, Simon A.; Leuenberger, Daiana; Ackermann, Andreas; Pascale, Céline; Niederhauser, Bernhard; Reimann, Stefan
2018-06-01
For many years, the comparability of measurements obtained with various instruments within a global-scale air quality monitoring network has been ensured by anchoring all results to a unique suite of reference gas mixtures, also called a primary calibration scale
. Such suites of reference gas mixtures are usually prepared and then stored over decades in pressurised cylinders by a designated laboratory. For the halogenated gases which have been measured over the last 40 years, this anchoring method is highly relevant as measurement reproducibility is currently much better ( < 1 %, k = 2 or 95 % confidence interval) than the expanded uncertainty of a reference gas mixture (usually > 2 %). Meanwhile, newly emitted halogenated gases are already measured in the atmosphere at pmol mol-1 levels, while still lacking an established reference standard. For compounds prone to adsorption on material surfaces, it is difficult to evaluate mixture stability and thus variations in the molar fractions over time in cylinders at pmol mol-1 levels.To support atmospheric monitoring of halogenated gases, we create new primary calibration scales for SF6 (sulfur hexafluoride), HFC-125 (pentafluoroethane), HFO-1234yf (or HFC-1234yf, 2,3,3,3-tetrafluoroprop-1-ene), HCFC-132b (1,2-dichloro-1,1-difluoroethane) and CFC-13 (chlorotrifluoromethane). The preparation method, newly applied to halocarbons, is dynamic and gravimetric: it is based on the permeation principle followed by dynamic dilution and cryo-filling of the mixture in cylinders. The obtained METAS-2017 primary calibration scales are made of 11 cylinders containing these five substances at near-ambient and slightly varying molar fractions. Each prepared molar fraction is traceable to the realisation of SI units (International System of Units) and is assigned an uncertainty estimate following international guidelines (JCGM, 2008), ranging from 0.6 % for SF6 to 1.3 % (k = 2) for all other substances. The smallest uncertainty obtained for SF6 is mostly explained by the high substance purity level in the permeator and the low SF6 contamination of the matrix gas. The measured internal consistency of the suite ranges from 0.23 % for SF6 to 1.1 % for HFO-1234yf (k = 1). The expanded uncertainty after verification (i.e. measurement of the cylinders vs. each others) ranges from 1 to 2 % (k = 2).This work combines the advantages of SI-traceable reference gas mixture preparation with a calibration scale system for its use as anchor by a monitoring network. Such a combined system supports maximising compatibility within the network while linking all reference values to the SI and assigning carefully estimated uncertainties.For SF6, comparison of the METAS-2017 calibration scale with the scale prepared by SIO (Scripps Institution of Oceanography, SIO-05) shows excellent concordance, the ratio METAS-2017 / SIO-05 being 1.002. For HFC-125, the METAS-2017 calibration scale is measured as 7 % lower than SIO-14; for HFO-1234yf, it is 9 % lower than Empa-2013. No other scale for HCFC-132b was available for comparison. Finally, for CFC-13 the METAS-2017 primary calibration scale is 5 % higher than the interim calibration scale (Interim-98) that was in use within the Advanced Global Atmospheric Gases Experiment (AGAGE) network before adopting the scale established in the present work.
NASA Astrophysics Data System (ADS)
Brunini, C.; Meza, A.; Gende, M.; Azpilicueta, F.
2008-08-01
SIRGAS (Geocentric Reference Frame for the Americas) is an international enterprise of the geodetic community that aims to realize the Terrestrial Reference Frame in the America's countries. In order to fulfill this commitment, SIRGAS manages a network of continuously operational GNSS receivers totalling around one hundred sites in the Caribbean, Central, and South American region. Although the network was not planed for ionospheric studies, its potential to be used for such a purpose was recently recognized and SIRGAS started a pilot experiment devoted to establish a regular service for computing and releasing regional vertical TEC (vTEC) maps based on GNSS data. Since July, 2005, the GESA (Geodesia Espacial y Aeronomía) laboratory belonging to the Facultad de Ciencias Astronómicas y Geofísicas of the Universidad Nacional de La Plata computes hourly maps of vertical Total Electron Content (vTEC) in the framework of the SIRGAS pilot experiment. These maps exploit all the GNSS data available in the South American region and are computed with the LPIM (La Plata Ionospheric Model). LPIM implements a de-biasing procedure that improves data calibration in relation to other procedures commonly used for such purposes. After calibration, slant TEC measurements are converted to vertical and mapped using local-time and modip latitude. The use of modip latitude smoothed the spatial variability of vTEC, especially in the South American low latitude region and hence allows for a better vTEC interpolation. This contribution summarizes the results obtained by GESA in the framework of the SIRGAS pilot experiment.
Science and ethics meet: a mathematical view on one kind of violation of publication ethics
NASA Astrophysics Data System (ADS)
Shinyaeva, Taisiya S.; Tarasevich, Yuri Yu
2018-01-01
When a person who did not make a significant intellectual contribution to a published research is included into the co-author list, the person is called gift or guest author depending on the reason why the person has been added to the co-authors. Essential deviation of properties of a particular co-author network from typical values may evidenced that the network is artificial. Using network analysis, we have performed an attempt to characterize a typical co-author network. We performed analysis of the co-author networks using references in the thesis on Physics and Mathematics, Economics defended from 2012 to 2017 and planned to be defended in 2017 and 2018 in Russia. Properties of the co-author networks are expected to be a reference sample in future research.
Minimum spanning tree analysis of the human connectome
Sommer, Iris E.; Bohlken, Marc M.; Tewarie, Prejaas; Draaisma, Laurijn; Zalesky, Andrew; Di Biase, Maria; Brown, Jesse A.; Douw, Linda; Otte, Willem M.; Mandl, René C.W.; Stam, Cornelis J.
2018-01-01
Abstract One of the challenges of brain network analysis is to directly compare network organization between subjects, irrespective of the number or strength of connections. In this study, we used minimum spanning tree (MST; a unique, acyclic subnetwork with a fixed number of connections) analysis to characterize the human brain network to create an empirical reference network. Such a reference network could be used as a null model of connections that form the backbone structure of the human brain. We analyzed the MST in three diffusion‐weighted imaging datasets of healthy adults. The MST of the group mean connectivity matrix was used as the empirical null‐model. The MST of individual subjects matched this reference MST for a mean 58%–88% of connections, depending on the analysis pipeline. Hub nodes in the MST matched with previously reported locations of hub regions, including the so‐called rich club nodes (a subset of high‐degree, highly interconnected nodes). Although most brain network studies have focused primarily on cortical connections, cortical–subcortical connections were consistently present in the MST across subjects. Brain network efficiency was higher when these connections were included in the analysis, suggesting that these tracts may be utilized as the major neural communication routes. Finally, we confirmed that MST characteristics index the effects of brain aging. We conclude that the MST provides an elegant and straightforward approach to analyze structural brain networks, and to test network topological features of individual subjects in comparison to empirical null models. PMID:29468769
A Multi-User Remote Academic Laboratory System
ERIC Educational Resources Information Center
Barrios, Arquimedes; Panche, Stifen; Duque, Mauricio; Grisales, Victor H.; Prieto, Flavio; Villa, Jose L.; Chevrel, Philippe; Canu, Michael
2013-01-01
This article describes the development, implementation and preliminary operation assessment of Multiuser Network Architecture to integrate a number of Remote Academic Laboratories for educational purposes on automatic control. Through the Internet, real processes or physical experiments conducted at the control engineering laboratories of four…
Clinical pathology accreditation: standards for the medical laboratory
Burnett, D; Blair, C; Haeney, M R; Jeffcoate, S L; Scott, K W M; Williams, D L
2002-01-01
This article describes a new set of revised standards for the medical laboratory, which have been produced by Clinical Pathology Accreditation (UK) Ltd (CPA). The original standards have been in use since 1992 and it was recognised that extensive revision was required. A standards revision group was established by CPA and this group used several international standards as source references, so that the resulting new standards are compatible with the most recent international reference sources. The aim is to make the assessment of medical laboratories as objective as possible in the future. CPA plans to introduce these standards in the UK in 2003 following extensive consultation with professional bodies, piloting in selected laboratories, and training of assessors. PMID:12354795
Do Graduate Teaching Assistants Benefit from Teaching Inquiry-Based Laboratories?
ERIC Educational Resources Information Center
French, Donald; Russell, Connie
2002-01-01
Introduces a study investigating graduate teaching assistants' (GTA) perceptions on their role in conducting laboratories and explores the benefits of inquiry-based laboratories for GTAs considering their experiences and knowledge. (Contains 22 references.) (YDS)
ERIC Educational Resources Information Center
Flaherty, Aishling; O'Dwyer, Anne; Mannix-McNamara, Patricia; Leahy, J. J.
2017-01-01
Throughout countries such as Ireland, the U.K., and Australia, graduate students who fulfill teaching roles in the undergraduate laboratory are often referred to as "laboratory demonstrators". The laboratory demonstrator (LD) model of graduate teaching is similar to the more commonly known graduate teaching assistant (GTA) model that is…
Federal Emergency Management Information System (FEMIS) system administration guide, version 1.4.5
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arp, J.A.; Burnett, R.A.; Carter, R.J.
The Federal Emergency Management Information Systems (FEMIS) is an emergency management planning and response tool that was developed by the Pacific Northwest National Laboratory (PNNL) under the direction of the US Army Chemical Biological Defense Command. The FEMIS System Administration Guide provides information necessary for the system administrator to maintain the FEMIS system. The FEMIS system is designed for a single Chemical Stockpile Emergency Preparedness Program (CSEPP) site that has multiple Emergency Operations Centers (EOCs). Each EOC has personal computers (PCs) that emergency planners and operations personnel use to do their jobs. These PCs are connected via a local areamore » network (LAN) to servers that provide EOC-wide services. Each EOC is interconnected to other EOCs via a Wide Area Network (WAN). Thus, FEMIS is an integrated software product that resides on client/server computer architecture. The main body of FEMIS software, referred to as the FEMIS Application Software, resides on the PC client(s) and is directly accessible to emergency management personnel. The remainder of the FEMIS software, referred to as the FEMIS Support Software, resides on the UNIX server. The Support Software provides the communication, data distribution, and notification functionality necessary to operate FEMIS in a networked, client/server environment. The UNIX server provides an Oracle relational database management system (RDBMS) services, ARC/INFO GIS (optional) capabilities, and basic file management services. PNNL developed utilities that reside on the server include the Notification Service, the Command Service that executes the evacuation model, and AutoRecovery. To operate FEMIS, the Application Software must have access to a site specific FEMIS emergency management database. Data that pertains to an individual EOC`s jurisdiction is stored on the EOC`s local server. Information that needs to be accessible to all EOCs is automatically distributed by the FEMIS database to the other EOCs at the site.« less
Selliah, S S; Cussion, S; MacPherson, K A; Reiner, E J; Toner, D
2001-06-01
Matrix-matched environmental certified reference materials (CRMs) are one of the most useful tools to validate analytical methods, assess analytical laboratory performance and to assist in the resolution of data conflicts between laboratories. This paper describes the development of a lake sediment as a CRM for polychorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and dioxin-like polychlorinated biphenyls (DLPCBs). The presence of DLPCBs in the environment is of increased concern and analytical methods are being developed internationally for monitoring DLPCBs in the environment. This paper also reports the results of an international interlaboratory study involving thirty-five laboratories from seventeen countries, conducted to characterize and validate levels of a sediment reference material for PCDDs, PCDFs and DLPCBs.
Recent developments in the field of environmental reference materials at the JRC Ispra.
Muntau, H
2001-06-01
The production of reference materials for environmental analysis started in the Joint Research Centre at Ispra/Italy in 1972 with the objective of later certification by the BCR, but for obvious budget reasons only a fraction of the total production achieved at Ispra ever reached certification level, although all materials were produced according to the severe quality requirements requested for certified reference materials. Therefore, the materials not destinated to certification are in growing demand as inter-laboratory test materials and as laboratory reference materials, for internal quality control, e.g., by control charts. The history of reference material production within the Joint Research Centre is briefly reviewed and the latest additions described. New developments such as micro-scale reference materials intended for analytical methods requiring sample intakes at milligram or sub-milligram level and therefor not finding supply on the reference material market, and "wet" environmental reference materials, which meet more precisely the "real-world" environmental analysis conditions, are presented and the state-of-the-art discussed.
25 years of HBM in the Czech Republic.
Černá, Milena; Puklová, Vladimíra; Hanzlíková, Lenka; Sochorová, Lenka; Kubínová, Růžena
2017-03-01
Since 1991 a human biomonitoring network has been established in the Czech Republic as part of the Environmental Health Monitoring System, which was set out by the Government Resolution. During the last quarter-century, important data was obtained to characterize exposure to both children and adult populations to significant toxic substances from the environment, to development trends over time, to establish reference values and compare them with existing health-related values. Moreover, the saturation of population with several essential substances as selenium, zinc, copper or iodine has also been monitored. Development of analytical and statistical methods led to increase the capacity building, improvement of QA/QC in analytical laboratories and interpretation of results. The obtained results are translated to policy actions and are used in health risk assessment processes at local and national levels. Copyright © 2016 Elsevier GmbH. All rights reserved.
The Water Laboratory Alliance (WLA), within Environmental Response Laboratory Network, maintains analytical capability and capacity in the event of intentional and unintentional water contamination with chemical, biological and radiochemical contaminants.
[Influence of the social network on consumption in drug addicts exhibiting psychiatric comorbidity].
Acier, D; Nadeau, L; Landry, M
2011-09-01
This research used a qualitative methodology and was conducted on a sample of 22 participants with concomitant substance-related and mental health disorders. Today, dual diagnosis patients represent the standard rather than the exception. Our objectives were to consider the elements and processes of the social network to explain variations in consumption of alcohol and drugs. The social network refers to all bonds established by patients, mainly family, couple, friends and therapist relationships. The 22 patients have used a specialized addiction treatment in Montreal (Canada). A focused qualitative interview was conducted with each participant using an audionumeric recording. The analysis follows the method of the mixed approach of Miles and Huberman, which combines the objectives of the grounded theory and the ethnography. All the interviews were transcribed then coded and analyzed with QSR N' Vivo 2.0. The method uses an iterative process making a constant return between verbatim and codes. The qualitative analyses present patients' perceptions on the increases and reductions in alcohol and drug consumption. Family network refers to participants where the family is named as supporting a decrease in drug consumption: couple network refers to intimate relations supporting a decrease in consumption. Mutual help network refers to alcoholics anonymous (AA) or other self-help groups. Several verbatim have been included. We propose strategies for the substance abuse treatment centers based on: (1) the paradox influence of the social network and the importance of clinical evaluation of patients of social networks; (2) emotions management, especially negative feelings, which include training of feeling, recognizing and naming, ability to the express and communicate to others; (3) importance of groups of mutual aid providing periods of sharing, validating individual experiences and pushing away loneliness; (4) function of social support of the clinical professionals as substitute of an overdrawn network. Copyright © 2011. Published by Elsevier Masson SAS.
ERIC Educational Resources Information Center
Lazinger, Susan S.
1991-01-01
Describes ALEPH, the research library network in Israel, and analyzes the strengths and weaknesses of its decentralized structure. Highlights include comparisons between RLIN and ALEPH; centralized versus decentralized networks; the format of ALEPH; authority control in ALEPH; and non-Roman scripts in both networks. (16 references) (LRW)
Mögling, Ramona; Zeller, Hervé; Revez, Joana; Koopmans, Marion; Reusken, Chantal
2017-01-01
With international travel, Zika virus (ZIKV) is introduced to Europe regularly. A country's ability to robustly detect ZIKV introduction and local transmission is important to minimise the risk for a ZIKV outbreak. Therefore, sufficient expertise and diagnostic capacity and capability are required in European laboratories. To assess the capacity, quality, operational specifics (guidelines and algorithms), technical and interpretation issues and other possible difficulties that were related to ZIKV diagnostics in European countries, a questionnaire was conducted among national reference laboratories in 30 countries in the European Union/European Economic Area (EU/EEA) in May 2016. While the coverage and capacity of ZIKV diagnostics in the EU/EEA national reference laboratories were found to be adequate, the assessment of the quality and needs indicated several crucial points of improvement that will need support at national and EU/EEA level to improve ZIKV preparedness, response and EU/EEA ZIKV surveillance activities. PMID:28920574
Using E-Mail across Computer Networks.
ERIC Educational Resources Information Center
Hazari, Sunil
1990-01-01
Discusses the use of telecommunications technology to exchange electronic mail, files, and messages across different computer networks. Networks highlighted include ARPA Internet; BITNET; USENET; FidoNet; MCI Mail; and CompuServe. Examples of the successful use of networks in higher education are given. (Six references) (LRW)
Neural network-based model reference adaptive control system.
Patino, H D; Liu, D
2000-01-01
In this paper, an approach to model reference adaptive control based on neural networks is proposed and analyzed for a class of first-order continuous-time nonlinear dynamical systems. The controller structure can employ either a radial basis function network or a feedforward neural network to compensate adaptively the nonlinearities in the plant. A stable controller-parameter adjustment mechanism, which is determined using the Lyapunov theory, is constructed using a sigma-modification-type updating law. The evaluation of control error in terms of the neural network learning error is performed. That is, the control error converges asymptotically to a neighborhood of zero, whose size is evaluated and depends on the approximation error of the neural network. In the design and analysis of neural network-based control systems, it is important to take into account the neural network learning error and its influence on the control error of the plant. Simulation results showing the feasibility and performance of the proposed approach are given.
Harvey, Stephen B; Krimer, Paula M; Correa, Maria T; Hanes, Martha A
2008-07-01
Plasma biochemical and hematologic values are important parameters for assessing animal health and experimental results. Although normal reference values for many rodent species have been published, there is a dearth of similar information for the genus Microtus. In addition, most studies use a mean and standard deviation to establish reference intervals, but doing so is not the recommendation of the Clinical and Laboratory Standards Institute (formerly the National Committee on Clinical Laboratory Standards) or the International Federation of Clinical Chemistry and Laboratory Medicine. The purpose of this study was to establish normal reference parameters for plasma biochemistry and hematology in mature pine voles (Microtus pinetorum) by using the nonparametric rank percentile method as recommended by the 2 laboratory medicine organizations mentioned. Samples of cardiac blood from a closed colony of pine voles were collected at euthanasia and evaluated under rodent settings on 2 automated hematology analyzers from 2 different manufacturers and on the same type of automated biochemistry analyzer. There were no sex-associated clinically significant differences between the sexes; younger animals had a lower hematocrit, higher mean corpuscular volume, and lower mean corpuscular hemoglobin concentration than did older animals. Only platelet counts differed when comparing hematologic values from different analyzers. Relative to rats and mice, pine voles have a lower mean corpuscular volume and higher red blood cell count, higher blood urea nitrogen, much higher alanine aminotransferase, and lower glucose and phosphorous concentrations. Hematology and plasma biochemical results obtained in this study are considered representative for healthy adult laboratory pine voles under similar environmental conditions.
Pérez, Teresa; Makrestsov, Nikita; Garatt, John; Torlakovic, Emina; Gilks, C Blake; Mallett, Susan
The Canadian Immunohistochemistry Quality Control program monitors clinical laboratory performance for estrogen receptor and progesterone receptor tests used in breast cancer treatment management in Canada. Current methods assess sensitivity and specificity at each time point, compared with a reference standard. We investigate alternative performance analysis methods to enhance the quality assessment. We used 3 methods of analysis: meta-analysis of sensitivity and specificity of each laboratory across all time points; sensitivity and specificity at each time point for each laboratory; and fitting models for repeated measurements to examine differences between laboratories adjusted by test and time point. Results show 88 laboratories participated in quality control at up to 13 time points using typically 37 to 54 histology samples. In meta-analysis across all time points no laboratories have sensitivity or specificity below 80%. Current methods, presenting sensitivity and specificity separately for each run, result in wide 95% confidence intervals, typically spanning 15% to 30%. Models of a single diagnostic outcome demonstrated that 82% to 100% of laboratories had no difference to reference standard for estrogen receptor and 75% to 100% for progesterone receptor, with the exception of 1 progesterone receptor run. Laboratories with significant differences to reference standard identified with Generalized Estimating Equation modeling also have reduced performance by meta-analysis across all time points. The Canadian Immunohistochemistry Quality Control program has a good design, and with this modeling approach has sufficient precision to measure performance at each time point and allow laboratories with a significantly lower performance to be targeted for advice.
WHO Melting-Point Reference Substances
Bervenmark, H.; Diding, N. Å.; Öhrner, B.
1963-01-01
Batches of 13 highly purified chemicals, intended for use as reference substances in the calibration of apparatus for melting-point determinations, have been subjected to a collaborative assay by 15 laboratories in 13 countries. All the laboratories performed melting-point determinations by the capillary methods described in the proposed text for the second edition of the Pharmacopoea Internationalis and some, in addition, carried out determinations by the microscope hot stage (Kofler) method, using both the “going-through” and the “equilibrium” technique. Statistical analysis of the data obtained by the capillary method showed that the within-laboratory variation was small and that the between-laboratory variation, though constituting the greatest part of the whole variance, was not such as to warrant the exclusion of any laboratory from the evaluation of the results. The average values of the melting-points obtained by the laboratories can therefore be used as constants for the substances in question, which have accordingly been established as WHO Melting-Point Reference Substances and included in the WHO collection of authentic chemical substances. As to the microscope hot stage method, analysis of the results indicated that the values obtained by the “going-through” technique did not differ significantly from those obtained by the capillary method, but the values obtained by the “equilibrium” technique were mostly significantly lower. PMID:20604137
NASA Astrophysics Data System (ADS)
Deng, Liansheng; Jiang, Weiping; Li, Zhao; Chen, Hua; Wang, Kaihua; Ma, Yifang
2017-02-01
Higher-order ionospheric (HOI) delays are one of the principal technique-specific error sources in precise global positioning system analysis and have been proposed to become a standard part of precise GPS data processing. In this research, we apply HOI delay corrections to the Crustal Movement Observation Network of China's (CMONOC) data processing (from January 2000 to December 2013) and furnish quantitative results for the effects of HOI on CMONOC coordinate time series. The results for both a regional reference frame and global reference frame are analyzed and compared to clarify the HOI effects on the CMONOC network. We find that HOI corrections can effectively reduce the semi-annual signals in the northern and vertical components. For sites with lower semi-annual amplitudes, the average decrease in magnitude can reach 30 and 10 % for the northern and vertical components, respectively. The noise amplitudes with HOI corrections and those without HOI corrections are not significantly different. Generally, the HOI effects on CMONOC networks in a global reference frame are less obvious than the results in the regional reference frame, probably because the HOI-induced errors are smaller in comparison to the higher noise levels seen when using a global reference frame. Furthermore, we investigate the combined contributions of environmental loading and HOI effects on the CMONOC stations. The largest loading effects on the vertical displacement are found in the mid- to high-latitude areas. The weighted root mean square differences between the corrected and original weekly GPS height time series of the loading model indicate that the mass loading adequately reduced the scatter on the CMONOC height time series, whereas the results in the global reference frame showed better agreements between the GPS coordinate time series and the environmental loading. When combining the effects of environmental loading and HOI corrections, the results with the HOI corrections reduced the scatter on the observed GPS height coordinates better than the height when estimated without HOI corrections, and the combined solutions in the regional reference frame indicate more preferred improvements. Therefore, regional reference frames are recommended to investigate the HOI effects on regional networks.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
The Computing and Communications (C) Division is responsible for the Laboratory`s Integrated Computing Network (ICN) as well as Laboratory-wide communications. Our computing network, used by 8,000 people distributed throughout the nation, constitutes one of the most powerful scientific computing facilities in the world. In addition to the stable production environment of the ICN, we have taken a leadership role in high-performance computing and have established the Advanced Computing Laboratory (ACL), the site of research on experimental, massively parallel computers; high-speed communication networks; distributed computing; and a broad variety of advanced applications. The computational resources available in the ACL are ofmore » the type needed to solve problems critical to national needs, the so-called ``Grand Challenge`` problems. The purpose of this publication is to inform our clients of our strategic and operating plans in these important areas. We review major accomplishments since late 1990 and describe our strategic planning goals and specific projects that will guide our operations over the next few years. Our mission statement, planning considerations, and management policies and practices are also included.« less
Interior. Balance room for chemistry laboratory. Storage room for glassware ...
Interior. Balance room for chemistry laboratory. Storage room for glassware and reference room with frequently used chemistry and chemical engineering texts. - Thomas A. Edison Laboratories, Building No. 2, Main Street & Lakeside Avenue, West Orange, Essex County, NJ
DDN (Defence Data Network) Protocol Implementations and Vendors Guide
1988-08-01
Artificial Intelligence Laboratory Room NE43-723 545 Technology Square Cambridge, MA 02139 (617) 253-8843 S John Wroclawski, (JTW@AI.AJ.MIT.EDU...Massachusetts Institute of Technology Artificial Intelligence Laboratory Room NE43-743 545 Technology Square 0 Cambridge, MA 02139 (617) 253-7885 ORDERING...TCP/IP Network Software for PC-DOS Systems CPU: IBM-PC/XT/AT/compatible in conjunction with EXOS 205 Inteligent Ethernet Controller for PCbus 0/s
NASA Technical Reports Server (NTRS)
1975-01-01
Formalized technical reporting is described and indexed, which resulted from scientific and engineering work performed, or managed, by the Jet Propulsion Laboratory. The five classes of publications included are technical reports, technical memorandums, articles from the bimonthly Deep Space Network Progress Report, special publications, and articles published in the open literature. The publications are indexed by author, subject, and publication type and number.
Digital echocardiography 2002: now is the time
NASA Technical Reports Server (NTRS)
Thomas, James D.; Greenberg, Neil L.; Garcia, Mario J.
2002-01-01
The ability to acquire echocardiographic images digitally, store and transfer these data using the DICOM standard, and routinely analyze examinations exists today and allows the implementation of a digital echocardiography laboratory. The purpose of this review article is to outline the critical components of a digital echocardiography laboratory, discuss general strategies for implementation, and put forth some of the pitfalls that we have encountered in our own implementation. The major components of the digital laboratory include (1) digital echocardiography machines with network output, (2) a switched high-speed network, (3) a high throughput server with abundant local storage, (4) a reliable low-cost archive, (5) software to manage information, and (6) support mechanisms for software and hardware. Implementation strategies can vary from a complete vendor solution providing all components (hardware, software, support), to a strategy similar to our own where standard computer and networking hardware are used with specialized software for management of image and measurement information.
Ialongo, Cristiano; Pieri, Massimo; Bernardini, Sergio
2017-02-01
Diluting a sample to obtain a measure within the analytical range is a common task in clinical laboratories. However, for urgent samples, it can cause delays in test reporting, which can put patients' safety at risk. The aim of this work is to show a simple artificial neural network that can be used to make it unnecessary to predilute a sample using the information available through the laboratory information system. Particularly, the Multilayer Perceptron neural network built on a data set of 16,106 cardiac troponin I test records produced a correct inference rate of 100% for samples not requiring predilution and 86.2% for those requiring predilution. With respect to the inference reliability, the most relevant inputs were the presence of a cardiac event or surgery and the result of the previous assay. Therefore, such an artificial neural network can be easily implemented into a total automation framework to sensibly reduce the turnaround time of critical orders delayed by the operation required to retrieve, dilute, and retest the sample.
ERIC Educational Resources Information Center
Koleza, Eugenia; Pappas, John
2008-01-01
In this article, we present the results of a qualitative research project on the effect of motion analysis activities in a Video-Based Laboratory (VBL) on students' understanding of position, velocity and frames of reference. The participants in our research were 48 pre-service teachers enrolled in Education Departments with no previous strong…
Reference intervals: current status, recent developments and future considerations.
Ozarda, Yesim
2016-01-01
Reliable and accurate reference intervals (RIs) for laboratory analyses are an integral part of the process of correct interpretation of clinical laboratory test results. RIs given in laboratory reports have an important role in aiding the clinician in interpreting test results in reference to values for healthy populations. Since the 1980s, the International Federation of Clinical Chemistry (IFCC) has been proactive in establishing recommendations to clarify the true significance of the term 'RIs, to select the appropriate reference population and statistically analyse the data. The C28-A3 guideline published by the Clinical and Laboratory Standards Institute (CLSI) and IFCC is still the most widely-used source of reference in this area. In recent years, protocols additional to the Guideline have been published by the IFCC, Committee on Reference Intervals and Decision Limits (C-RIDL), including all details of multicenter studies on RIs to meet the requirements in this area. Multicentric RIs studies are the most important development in the area of RIs. Recently, the C-RIDL has performed many multicentric studies to obtain common RIs. Confusion of RIs and clinical decision limits (CDLs) remains an issue and pediatric and geriatric age groups are a significant problem. For future studies of RIs, the genetic effect would seem to be the most challenging area. The aim of the review is to present the current theory and practice of RIs, with special emphasis given to multicenter RIs studies, RIs studies for pediatric and geriatric age groups, clinical decision limits and partitioning by genetic effects on RIs.
Reference intervals: current status, recent developments and future considerations
Ozarda, Yesim
2016-01-01
Reliable and accurate reference intervals (RIs) for laboratory analyses are an integral part of the process of correct interpretation of clinical laboratory test results. RIs given in laboratory reports have an important role in aiding the clinician in interpreting test results in reference to values for healthy populations. Since the 1980s, the International Federation of Clinical Chemistry (IFCC) has been proactive in establishing recommendations to clarify the true significance of the term ‘RIs, to select the appropriate reference population and statistically analyse the data. The C28-A3 guideline published by the Clinical and Laboratory Standards Institute (CLSI) and IFCC is still the most widely-used source of reference in this area. In recent years, protocols additional to the Guideline have been published by the IFCC, Committee on Reference Intervals and Decision Limits (C-RIDL), including all details of multicenter studies on RIs to meet the requirements in this area. Multicentric RIs studies are the most important development in the area of RIs. Recently, the C-RIDL has performed many multicentric studies to obtain common RIs. Confusion of RIs and clinical decision limits (CDLs) remains an issue and pediatric and geriatric age groups are a significant problem. For future studies of RIs, the genetic effect would seem to be the most challenging area. The aim of the review is to present the current theory and practice of RIs, with special emphasis given to multicenter RIs studies, RIs studies for pediatric and geriatric age groups, clinical decision limits and partitioning by genetic effects on RIs. PMID:26981015
Karita, Etienne; Ketter, Nzeera; Price, Matt A; Kayitenkore, Kayitesi; Kaleebu, Pontiano; Nanvubya, Annet; Anzala, Omu; Jaoko, Walter; Mutua, Gaudensia; Ruzagira, Eugene; Mulenga, Joseph; Sanders, Eduard J; Mwangome, Mary; Allen, Susan; Bwanika, Agnes; Bahemuka, Ubaldo; Awuondo, Ken; Omosa, Gloria; Farah, Bashir; Amornkul, Pauli; Birungi, Josephine; Yates, Sarah; Stoll-Johnson, Lisa; Gilmour, Jill; Stevens, Gwynn; Shutes, Erin; Manigart, Olivier; Hughes, Peter; Dally, Len; Scott, Janet; Stevens, Wendy; Fast, Pat; Kamali, Anatoli
2009-01-01
Clinical laboratory reference intervals have not been established in many African countries, and non-local intervals are commonly used in clinical trials to screen and monitor adverse events (AEs) among African participants. Using laboratory reference intervals derived from other populations excludes potential trial volunteers in Africa and makes AE assessment challenging. The objective of this study was to establish clinical laboratory reference intervals for 25 hematology, immunology and biochemistry values among healthy African adults typical of those who might join a clinical trial. Equal proportions of men and women were invited to participate in a cross sectional study at seven clinical centers (Kigali, Rwanda; Masaka and Entebbe, Uganda; two in Nairobi and one in Kilifi, Kenya; and Lusaka, Zambia). All laboratories used hematology, immunology and biochemistry analyzers validated by an independent clinical laboratory. Clinical and Laboratory Standards Institute guidelines were followed to create study consensus intervals. For comparison, AE grading criteria published by the U.S. National Institute of Allergy and Infectious Diseases Division of AIDS (DAIDS) and other U.S. reference intervals were used. 2,990 potential volunteers were screened, and 2,105 (1,083 men and 1,022 women) were included in the analysis. While some significant gender and regional differences were observed, creating consensus African study intervals from the complete data was possible for 18 of the 25 analytes. Compared to reference intervals from the U.S., we found lower hematocrit and hemoglobin levels, particularly among women, lower white blood cell and neutrophil counts, and lower amylase. Both genders had elevated eosinophil counts, immunoglobulin G, total and direct bilirubin, lactate dehydrogenase and creatine phosphokinase, the latter being more pronounced among women. When graded against U.S. -derived DAIDS AE grading criteria, we observed 774 (35.3%) volunteers with grade one or higher results; 314 (14.9%) had elevated total bilirubin, and 201 (9.6%) had low neutrophil counts. These otherwise healthy volunteers would be excluded or would require special exemption to participate in many clinical trials. To accelerate clinical trials in Africa, and to improve their scientific validity, locally appropriate reference ranges should be used. This study provides ranges that will inform inclusion criteria and evaluation of adverse events for studies in these regions of Africa.
Neural network for intelligent query of an FBI forensic database
NASA Astrophysics Data System (ADS)
Uvanni, Lee A.; Rainey, Timothy G.; Balasubramanian, Uma; Brettle, Dean W.; Weingard, Fred; Sibert, Robert W.; Birnbaum, Eric
1997-02-01
Examiner is an automated fired cartridge case identification system utilizing a dual-use neural network pattern recognition technology, called the statistical-multiple object detection and location system (S-MODALS) developed by Booz(DOT)Allen & Hamilton, Inc. in conjunction with Rome Laboratory. S-MODALS was originally designed for automatic target recognition (ATR) of tactical and strategic military targets using multisensor fusion [electro-optical (EO), infrared (IR), and synthetic aperture radar (SAR)] sensors. Since S-MODALS is a learning system readily adaptable to problem domains other than automatic target recognition, the pattern matching problem of microscopic marks for firearms evidence was analyzed using S-MODALS. The physics; phenomenology; discrimination and search strategies; robustness requirements; error level and confidence level propagation that apply to the pattern matching problem of military targets were found to be applicable to the ballistic domain as well. The Examiner system uses S-MODALS to rank a set of queried cartridge case images from the most similar to the least similar image in reference to an investigative fired cartridge case image. The paper presents three independent tests and evaluation studies of the Examiner system utilizing the S-MODALS technology for the Federal Bureau of Investigation.
Mexican Space Weather Service (SCiESMEX)
NASA Astrophysics Data System (ADS)
Gonzalez-Esparza, J. A.; De la Luz, V.; Corona-Romero, P.; Mejia-Ambriz, J. C.; Gonzalez, L. X.; Sergeeva, M. A.; Romero-Hernandez, E.; Aguilar-Rodriguez, E.
2017-01-01
Legislative modifications of the General Civil Protection Law in Mexico in 2014 included specific references to space hazards and space weather phenomena. The legislation is consistent with United Nations promotion of international engagement and cooperation on space weather awareness, studies, and monitoring. These internal and external conditions motivated the creation of a space weather service in Mexico. The Mexican Space Weather Service (SCiESMEX in Spanish) (www.sciesmex.unam.mx) was initiated in October 2014 and is operated by the Institute of Geophysics at the Universidad Nacional Autonoma de Mexico (UNAM). SCiESMEX became a Regional Warning Center of the International Space Environment Services (ISES) in June 2015. We present the characteristics of the service, some products, and the initial actions for developing a space weather strategy in Mexico. The service operates a computing infrastructure including a web application, data repository, and a high-performance computing server to run numerical models. SCiESMEX uses data of the ground-based instrumental network of the National Space Weather Laboratory (LANCE), covering solar radio burst emissions, solar wind and interplanetary disturbances (by interplanetary scintillation observations), geomagnetic measurements, and analysis of the total electron content (TEC) of the ionosphere (by employing data from local networks of GPS receiver stations).
Radley, Jason; Morilak, David; Viau, Victor; Campeau, Serge
2015-01-01
Stress responses entail neuroendocrine, autonomic, and behavioral changes to promote effective coping with real or perceived threats to one’s safety. While these responses are critical for the survival of the individual, adverse effects of repeated exposure to stress are widely known to have deleterious effects on health. Thus, a considerable effort in the search for treatments to stress-related CNS disorders necessitates unraveling the brain mechanisms responsible for adaptation under acute conditions and their perturbations following chronic stress exposure. This paper is based upon a symposium from the 2014 International Behavioral Neuroscience Meeting, summarizing some recent advances in understanding the effects of stress on adaptive and maladaptive responses subserved by limbic forebrain networks. An important theme highlighted in this review is that the same networks mediating neuroendocrine, autonomic, and behavioral processes during adaptive coping also comprise targets of the effects of repeated stress exposure in the development of maladaptive states. Where possible, reference is made to the similarity of neurobiological substrates and effects observed following repeated exposure to stress in laboratory animals and the clinical features of stress-related disorders in humans. PMID:26116544
NASA Astrophysics Data System (ADS)
Figueiredo, Bruno; Tsang, Chin-Fu; Niemi, Auli; Lindgren, Georg
2016-11-01
Laboratory and field experiments done on fractured rock show that flow and solute transport often occur along flow channels. `Sparse channels' refers to the case where these channels are characterised by flow in long flow paths separated from each other by large spacings relative to the size of flow domain. A literature study is presented that brings together information useful to assess whether a sparse-channel network concept is an appropriate representation of the flow system in tight fractured rock of low transmissivity, such as that around a nuclear waste repository in deep crystalline rocks. A number of observations are made in this review. First, conventional fracture network models may lead to inaccurate results for flow and solute transport in tight fractured rocks. Secondly, a flow dimension of 1, as determined by the analysis of pressure data in well testing, may be indicative of channelised flow, but such interpretation is not unique or definitive. Thirdly, in sparse channels, the percolation may be more influenced by the fracture shape than the fracture size and orientation but further studies are needed. Fourthly, the migration of radionuclides from a waste canister in a repository to the biosphere may be strongly influenced by the type of model used (e.g. discrete fracture network, channel model). Fifthly, the determination of appropriateness of representing an in situ flow system by a sparse-channel network model needs parameters usually neglected in site characterisation, such as the density of channels or fracture intersections.
[Mechanism of Tongsaimai tablet for atherosclerosis based on network pharmacology].
Li, Na; Zhang, Xin-Zhuang; Wang, Yan-Ru; Cao, Liang; Ding, Gang; Wang, Zhen-Zhong; Xiao, Wei; Xu, Xiao-Jie
2016-05-01
Network pharmacology method was adopted in this study to explore the active compounds and mechanism of Tongsaimai tablets for atherosclerosis. In molecular docking and molecular-target protein network analysis, 97 molecules in Tongsaimai tablets showed good interaction with the atherosclerosis-related target protein (docking score ≥ 7), and 37 molecules of them could act on more than 2 targets (≥ 2) with higher betweenness, suggesting that these 37 molecules might be the main active compounds group in Tongsaimai tablets for atherosclerosis treatment. Furthermore, the predicted active compounds contained more flavonoids and saponins, reminding more attention should be paid on flavonoids and saponins in study of effective compounds and quality standards of Tongsaimai tablets. Targets network analysis showed that, the active compounds of Tongsaimai tablets could regulate inflammation, stabilize plaque, protect vascular endothelial cell, regulate blood lipid and inhibit blood coagulation through acting on the main 22 target proteins, such as Toll-like receptors (TLR1, TLR2), matrix metalloproteinase (MMP1, MMP2, MMP3, MMP9), angiotensin converting enzyme (ACE), leukotriene A4 hydrolase (LTA4-H), 5-lipoxidase (5-LOX), peroxisome proliferators-activated receptors (PPARα, PPARγ). These active compounds can participate in regulating different pathologic stages of atherosclerosis and thus treat atherosclerosis finally. This study revealed the main active compounds and possible mechanism of Tongsaimai tablets for treatment of atherosclerosis and meanwhile, verified the characteristics of multi-components, multi-targets and integral regulation for Tongsaimai tablets, providing theoretical references for the following systematic laboratory experiments on effective compounds and action mechanism of Tongsaimai Tablet. Copyright© by the Chinese Pharmaceutical Association.
Computer Networks as a New Data Base.
ERIC Educational Resources Information Center
Beals, Diane E.
1992-01-01
Discusses the use of communication on computer networks as a data source for psychological, social, and linguistic research. Differences between computer-mediated communication and face-to-face communication are described, the Beginning Teacher Computer Network is discussed, and examples of network conversations are appended. (28 references) (LRW)
Electronic Communication in Engineering Work.
ERIC Educational Resources Information Center
Bishop, Ann P.
1992-01-01
Discusses the role of electronic networks in engineering work; reviews selected literature on engineering work, knowledge, and communication; describes current uses of electronic networks; and presents results from a study of the use of networks by engineers in the aerospace industry, including their perceptions of networks. (67 references) (LRW)
Pinheiro, Leonardo B; O'Brien, Helen; Druce, Julian; Do, Hongdo; Kay, Pippa; Daniels, Marissa; You, Jingjing; Burke, Daniel; Griffiths, Kate; Emslie, Kerry R
2017-11-07
Use of droplet digital PCR technology (ddPCR) is expanding rapidly in the diversity of applications and number of users around the world. Access to relatively simple and affordable commercial ddPCR technology has attracted wide interest in use of this technology as a molecular diagnostic tool. For ddPCR to effectively transition to a molecular diagnostic setting requires processes for method validation and verification and demonstration of reproducible instrument performance. In this study, we describe the development and characterization of a DNA reference material (NMI NA008 High GC reference material) comprising a challenging methylated GC-rich DNA template under a novel 96-well microplate format. A scalable process using high precision acoustic dispensing technology was validated to produce the DNA reference material with a certified reference value expressed in amount of DNA molecules per well. An interlaboratory study, conducted using blinded NA008 High GC reference material to assess reproducibility among seven independent laboratories demonstrated less than 4.5% reproducibility relative standard deviation. With the exclusion of one laboratory, laboratories had appropriate technical competency, fully functional instrumentation, and suitable reagents to perform accurate ddPCR based DNA quantification measurements at the time of the study. The study results confirmed that NA008 High GC reference material is fit for the purpose of being used for quality control of ddPCR systems, consumables, instrumentation, and workflow.
ERIC Educational Resources Information Center
Cohen, Moshe; And Others
Electronic networks provide new opportunities to create functional learning environments which allow students in many different locations to carry out joint educational activities. A set of participant observation studies was conducted in the context of a cross-cultural, cross-language network called the Intercultural Learning Network in order to…
Teaching Advanced Concepts in Computer Networks: VNUML-UM Virtualization Tool
ERIC Educational Resources Information Center
Ruiz-Martinez, A.; Pereniguez-Garcia, F.; Marin-Lopez, R.; Ruiz-Martinez, P. M.; Skarmeta-Gomez, A. F.
2013-01-01
In the teaching of computer networks the main problem that arises is the high price and limited number of network devices the students can work with in the laboratories. Nowadays, with virtualization we can overcome this limitation. In this paper, we present a methodology that allows students to learn advanced computer network concepts through…
Spatial interpolation of daily reference evapotranspiration in the Texas High Plains
USDA-ARS?s Scientific Manuscript database
The Texas High Plains Evapotranspiration (ET) Network collects meteorological data from 18 grass reference weather stations at hourly intervals and estimates hourly and daily reference ET using the American Society of Civil Engineers (ASCE) Standardized Reference ET equation. Producers in the Texas ...
... Clinical Overview Diagnosis & Testing Prevention in Health Care Settings Laboratory Testing Collecting VZV Specimens CDC National VZV Laboratory Surveillance Resources & References Multimedia Related Links Medline Plus NIH SeniorHealth ...
NASA Technical Reports Server (NTRS)
Bradley, D. B.; Cain, J. B., III; Williard, M. W.
1978-01-01
The task was to evaluate the ability of a set of timing/synchronization subsystem features to provide a set of desirable characteristics for the evolving Defense Communications System digital communications network. The set of features related to the approaches by which timing/synchronization information could be disseminated throughout the network and the manner in which this information could be utilized to provide a synchronized network. These features, which could be utilized in a large number of different combinations, included mutual control, directed control, double ended reference links, independence of clock error measurement and correction, phase reference combining, and self organizing.
Yin, Yue-Ping; Wei, Wan-Hui; Wang, Hong-Chun; Zhu, Bang-Yong; Yu, Yan-Hua; Chen, Xiang-Sheng; Peeling, Rosanna W; Cohen, Myron S
2009-03-01
China is experiencing a growing syphilis epidemic. Individuals are currently screened and cases are confirmed using traditional serological testing methods. A total of 11 558 serum specimens from patients at 14 sexually transmitted diseases (STD) clinics at provincial, prefecture and county levels in Guangxi Autonomous Region were tested at local clinics using the toluidine red unheated serum test (TRUST) and the SD Bioline Syphilis 3.0 Treponema Pallidum (SD-TP) test and then transported to the National STD Reference Laboratory for TRUST and confirmatory Treponema pallidum particle assay (TPPA) testing. In local clinics, 13.2% of specimens were TRUST positive and 12.8% were TRUST and SD-TP positive. At the Reference Laboratory, 15.4% of specimens were TRUST positive and 11.8% were TRUST and TPPA positive. Local clinics showed a significantly higher prevalence of active syphilis compared with results from the Reference Laboratory (12.8 v. 11.8%, chi(2) = 4.59, P = 0.03). The local TRUST tests had consistent results with Reference Laboratory tests qualitatively among 96.2% of the specimens and quantitatively among 95.5% of the specimens. The algorithm of TRUST screening and then SD-TP confirmation among positive TRUST specimens at local STD clinics had 96.6% sensitivity and 99.3% specificity in diagnosing active syphilis compared with the 'gold standard' based on TRUST and TPPA positivity at the Reference Laboratory (positive predictive value 95.1% and negative predictive value 99.5%). The TRUST screening and SD-TP confirmation in combination can be used at local STD clinics for the efficient diagnosis of serologically active syphilis. However, continuing capacity building and quality assurance remain critical in ensuring the quality of syphilis diagnosis at local clinics.
Measurement uncertainty: Friend or foe?
Infusino, Ilenia; Panteghini, Mauro
2018-02-02
The definition and enforcement of a reference measurement system, based on the implementation of metrological traceability of patients' results to higher order reference methods and materials, together with a clinically acceptable level of measurement uncertainty, are fundamental requirements to produce accurate and equivalent laboratory results. The uncertainty associated with each step of the traceability chain should be governed to obtain a final combined uncertainty on clinical samples fulfilling the requested performance specifications. It is important that end-users (i.e., clinical laboratory) may know and verify how in vitro diagnostics (IVD) manufacturers have implemented the traceability of their calibrators and estimated the corresponding uncertainty. However, full information about traceability and combined uncertainty of calibrators is currently very difficult to obtain. Laboratory professionals should investigate the need to reduce the uncertainty of the higher order metrological references and/or to increase the precision of commercial measuring systems. Accordingly, the measurement uncertainty should not be considered a parameter to be calculated by clinical laboratories just to fulfil the accreditation standards, but it must become a key quality indicator to describe both the performance of an IVD measuring system and the laboratory itself. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Safety in the Chemical Laboratory: Learning How to Run Safer Undergraduate Laboratories.
ERIC Educational Resources Information Center
Mohrig, Jerry R.
1983-01-01
Discusses responsibilities for providing safe experiments and for teaching about safety. Provides lists of references on chemical safety and regulated/potential carcinogens. Also discusses general laboratory safety procedures including waste disposal and recycling of solvents. (JM)
Environmental Response Laboratory Network Membership and Benefits
Member laboratories must meet core requirements including quality systems, policies and procedures, sample and data management, and analytical capabilities. Benefits include training and exercise opportunities, information sharing and technical support.
Artificial Neural Network Approach in Laboratory Test Reporting: Learning Algorithms.
Demirci, Ferhat; Akan, Pinar; Kume, Tuncay; Sisman, Ali Riza; Erbayraktar, Zubeyde; Sevinc, Suleyman
2016-08-01
In the field of laboratory medicine, minimizing errors and establishing standardization is only possible by predefined processes. The aim of this study was to build an experimental decision algorithm model open to improvement that would efficiently and rapidly evaluate the results of biochemical tests with critical values by evaluating multiple factors concurrently. The experimental model was built by Weka software (Weka, Waikato, New Zealand) based on the artificial neural network method. Data were received from Dokuz Eylül University Central Laboratory. "Training sets" were developed for our experimental model to teach the evaluation criteria. After training the system, "test sets" developed for different conditions were used to statistically assess the validity of the model. After developing the decision algorithm with three iterations of training, no result was verified that was refused by the laboratory specialist. The sensitivity of the model was 91% and specificity was 100%. The estimated κ score was 0.950. This is the first study based on an artificial neural network to build an experimental assessment and decision algorithm model. By integrating our trained algorithm model into a laboratory information system, it may be possible to reduce employees' workload without compromising patient safety. © American Society for Clinical Pathology, 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.