Qi, H.P.; Coplen, T.B.
2003-01-01
Soufre de Lacq elemental sulfur reference material (IAEA-S-4) isotopically is homogeneous in amounts as small as 41 ??g as determined by continuous flow isotope-ratio mass spectrometry. The ??34S value for this reference material is +16.90 ?? 0.12??? (1??) on a scale (Vienna Can??on Diablo troilite, VCDT) where IAEA-S-1 Ag2S is -0.3??? and IAEA-S-2 Ag2S is +22.67???. Published by Elsevier Science B.V.
Brand, Willi A.; Coplen, Tyler B.; Aerts-Bijma, Anita T.; Bohlke, John Karl; Gehre, Matthias; Geilmann, Heike; Groning, Manfred; Jansen, Henk G.; Meijer, Harro A. J.; Mroczkowski, Stanley J.; Qi, Haiping; Soergel, Karin; Stuart-Williams, Hilary; Weise, Stephan M.; Werner, Roland A.
2009-01-01
Internationally distributed organic and inorganic oxygen isotopic reference materials have been calibrated by six laboratories carrying out more than 5300 measurements using a variety of high-temperature conversion techniques (HTC) in an evaluation sponsored by the International Union of Pure and Applied Chemistry (IUPAC). To aid in the calibration of these reference materials, which span more than 125‰, an artificially enriched reference water (δ18O of +78.91‰) and two barium sulfates (one depleted and one enriched in 18O) were prepared and calibrated relative to VSMOW2 and SLAP reference waters. These materials were used to calibrate the other isotopic reference materials in this study, which yielded:Reference materialδ18O and estimated combined uncertainty IAEA-602 benzoic acid+71.28 ± 0.36‰USGS35 sodium nitrate+56.81 ± 0.31‰IAEA-NO-3 potassium nitrate+25.32 ± 0.29‰IAEA-601 benzoic acid+23.14 ± 0.19‰IAEA-SO-5 barium sulfate+12.13 ± 0.33‰NBS 127 barium sulfate+8.59 ± 0.26‰VSMOW2 water0‰IAEA-600 caffeine−3.48 ± 0.53‰IAEA-SO-6 barium sulfate−11.35 ± 0.31‰USGS34 potassium nitrate−27.78 ± 0.37‰SLAP water−55.5‰The seemingly large estimated combined uncertainties arise from differences in instrumentation and methodology and difficulty in accounting for all measurement bias. They are composed of the 3-fold standard errors directly calculated from the measurements and provision for systematic errors discussed in this paper. A primary conclusion of this study is that nitrate samples analyzed for δ18O should be analyzed with internationally distributed isotopic nitrates, and likewise for sulfates and organics. Authors reporting relative differences of oxygen-isotope ratios (δ18O) of nitrates, sulfates, or organic material should explicitly state in their reports the δ18O values of two or more internationally distributed nitrates (USGS34, IAEA-NO-3, and USGS35), sulfates (IAEA-SO-5, IAEA-SO-6, and NBS 127), or organic material (IAEA-601 benzoic acid, IAEA-602 benzoic acid, and IAEA-600 caffeine), as appropriate to the material being analyzed, had these reference materials been analyzed with unknowns. This procedure ensures that readers will be able to normalize the δ18O values at a later time should it become necessary.The high-temperature reduction technique for analyzing δ18O and δ2H is not as widely applicable as the well-established combustion technique for carbon and nitrogen stable isotope determination. To obtain the most reliable stable isotope data, materials should be treated in an identical fashion; within the same sequence of analyses, samples should be compared with working reference materials that are as similar in nature and in isotopic composition as feasible.
NASA Astrophysics Data System (ADS)
Ding, T.; Valkiers, S.; Kipphardt, H.; De Bièvre, P.; Taylor, P. D. P.; Gonfiantini, R.; Krouse, R.
2001-08-01
Calibrated values have been obtained for sulfur isotope abundance ratios of sulfur isotope reference materials distributed by the IAEA (Vienna). For the calibration of the measurements, a set of synthetic isotope mixtures were prepared gravimetrically from high purity Ag2S materials enriched in32S, 33S, and 34S. All materials were converted into SF6 gas and subsequently, their sulfur isotope ratios were measured on the SF5+ species using a special gas source mass spectrometer equipped with a molecular flow inlet system (IRMM's Avogadro II amount comparator). Values for the 32S/34S abundance ratios are 22.650 4(20), 22.142 4(20), and 23.393 3(17) for IAEA-S-1, IAEA-S-2, and IAEA-S-3, respectively. The calculated 32S/34S abundance ratio for V-CDT is 22.643 6(20), which is very close to the calibrated ratio obtained by Ding et al. (1999). In this way, the zero point of the VCDT scale is anchored firmly to the international system of units SI. The 32S/33S abundance ratios are 126.942(47), 125.473(55), 129.072(32), and 126.948(47) for IAEA-S-1, IAEA-S-2, IAEA-S-3, and V-CDT, respectively. In this way, the linearity of the V-CDT scale is improved over this range. The values of the sulfur molar mass for IAEA-S-1 and V-CDT were calculated to be 32.063 877(56) and 32.063 911(56), respectively, the values with the smallest combined uncertainty ever reported for the sulfur molar masses (atomic weights).
Pham, M K; van Beek, P; Carvalho, F P; Chamizo, E; Degering, D; Engeler, C; Gascó, C; Gurriaran, R; Hanley, O; Harms, A V; Herrmann, J; Hult, M; Ikeuchi, Y; Ilchmann, C; Kanisch, G; Kis-Benedek, G; Kloster, M; Laubenstein, M; Llaurado, M; Mas, J L; Nakano, M; Nielsen, S P; Osvath, I; Povinec, P P; Rieth, U; Schikowski, J; Smedley, P A; Suplinska, M; Sýkora, I; Tarjan, S; Varga, B; Vasileva, E; Zalewska, T; Zhou, W
2016-03-01
The preparation and characterization of certified reference materials (CRMs) for radionuclide content in sediments collected offshore of Bikini Atoll (IAEA-410) and in the open northwest Pacific Ocean (IAEA-412) are described and the results of the certification process are presented. The certified radionuclides include: (40)K, (210)Pb ((210)Po), (226)Ra, (228)Ra, (228)Th, (232)Th, (234)U, (238)U, (239)Pu, (239+240)Pu and (241)Am for IAEA-410 and (40)K, (137)Cs, (210)Pb ((210)Po), (226)Ra, (228)Ra, (228)Th, (232)Th, (235)U, (238)U, (239)Pu, (240)Pu and (239+240)Pu for IAEA-412. The CRMs can be used for quality assurance and quality control purposes in the analysis of radionuclides in sediments, for development and validation of analytical methods and for staff training. Copyright © 2015 Elsevier Ltd. All rights reserved.
UO 2 Particle Standards: Synthesis, Purification & Planchet Preparation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barrett, Christopher A.; Anheier, Norman C.
2016-03-31
The IAEA has previously indicated its desire for reliable provision of suitable reference materials in support of environmental sample analysis and sustained advancement at the Department of Safeguards, as laid out in the Long Term R&D plan (LTRD 10.1 & 10.2). In a recent meeting between NPAC, the IAEA and PNNL, this pressing need was directly outlined by the IAEA as having two main objectives. The first pertains to current operations, such as instrument calibrations and evaluation of bias across the Network of Analytical Laboratories and requires particles on the order of 300-500 nm in diameter. The second need formore » particle reference material would directly support the IAEA’s ongoing R&D efforts and calls for smaller particles ranging from 50 -100 nm in size. As such, the IAEA has expressed a great deal of interest in the newly established synthesis capabilities at PNNL, initially cultivated through a PNNL LDRD project to address the particle-standards shortcomings for uranium oxide material. The joint meeting concluded with a request by the IAEA for 1-2 planchet samples containing PNNL’s UO 2 particulate material, to be delivered in the near-term. This report outlines the steps taken to meet that request and includes some basic characteristics of the samples sent to the IAEA.« less
Michel, H; Levent, D; Barci, V; Barci-Funel, G; Hurel, C
2008-02-15
A new sequential method for the determination of both natural (U, Th) and anthropogenic (Sr, Cs, Pu, Am) radionuclides has been developed for application to soil and sediment samples. The procedure was optimised using a reference sediment (IAEA-368) and reference soils (IAEA-375 and IAEA-326). Reference materials were first digested using acids (leaching), 'total' acids on hot plate, and acids in microwave in order to compare the different digestion technique. Then, the separation and purification were made by anion exchange resin and selective extraction chromatography: transuranic (TRU) and strontium (SR) resins. Natural and anthropogenic alpha radionuclides were separated by uranium and tetravalent actinide (UTEVA) resin, considering different acid elution medium. Finally, alpha and gamma semiconductor spectrometer and liquid scintillation spectrometer were used to measure radionuclide activities. The results obtained for strontium-90, cesium-137, thorium-232, uranium-238, plutonium-239+240 and americium-241 isotopes by the proposed method for the reference materials provided excellent agreement with the recommended values and good chemical recoveries. Plutonium isotopes in alpha spectrometry planchet deposits could be also analysed by ICPMS.
Huy, Ngo Quang; Binh, Do Quang
2014-12-01
This work suggests a method for determining the activities of cylindrical radioactive samples. The self-attenuation factor was applied for providing the self-absorption correction of gamma rays in the sample material. The experimental measurement of a (238)U reference sample and the calculation using the MCNP5 code allow obtaining the semi-empirical formulae of detecting efficiencies for the gamma energies ranged from 185 to 1764keV. These formulae were used to determine the activities of the (238)U, (226)Ra, (232)Th, (137)Cs and (40)K nuclides in the IAEA RGU-1, IAEA-434, IAEA RGTh-1, IAEA-152 and IAEA RGK-1 radioactive standards. The coincidence summing corrections for gamma rays in the (238)U and (232)Th series were applied. The activities obtained in this work were in good agreement with the reference values. Copyright © 2014 Elsevier Ltd. All rights reserved.
Ceccatelli, A; Katona, R; Kis-Benedek, G; Pitois, A
2014-05-01
The analytical performance of gamma-ray spectrometry for the measurement of (226)Ra in TENORM (Technically Enhanced Naturally Occurring Radioactive Material) soil was investigated by the IAEA. Fast results were obtained for characterization and certification of a new TENORM Certified Reference Material (CRM), identified as IAEA-448 (soil from oil field). The combined standard uncertainty of the gamma-ray spectrometry results is of the order of 2-3% for massic activity measurement values ranging from 16500 Bq kg(-1) to 21500 Bq kg(-1). Methodologies used for the production and certification of the IAEA-448 CRM are presented. Analytical results were confirmed by alpha spectrometry. The "t" test showed agreement between alpha and gamma results at 95% confidence level. © 2013 Published by Elsevier Ltd.
Tolosa, Imma; Cassi, Roberto; Huertas, David
2018-04-11
A new marine sediment certified reference material (IAEA 459) with very low concentrations (μg kg -1 ) for a variety of persistent organic contaminants (POPs) listed by the Stockholm Convention, as well as other POPs and priority substances (PSs) listed in many environmental monitoring programs was developed by the IAEA. The sediment material was collected from the Ham River estuary in South Korea, and the assigned final values were derived from robust statistics on the results provided by selected laboratories which demonstrated technical and quality competence, following the guidance given in ISO Guide 35. The robust mean of the laboratory means was assigned as certified values, for those compounds where the assigned value was derived from at least five datasets and its relative expanded uncertainty was less than 40% of the assigned value (most of the values ranging from 8 to 20%). All the datasets were derived from at least two different analytical techniques which have allowed the assignment of certified concentrations for 22 polychlorinated biphenyl (PCB) congeners, 6 organochlorinated (OC) pesticides, 5 polybrominated diphenyl ethers (PBDEs), and 18 polycyclic aromatic hydrocarbon (PAHs). Mass fractions of compounds that did not fulfill the criteria of certification are considered information values, which include 29 PAHs, 11 PCBs, 16 OC pesticides, and 5 PBDEs. The extensive characterization and associated uncertainties at concentration levels close to the marine sediment quality guidelines will make CRM 459 a valuable matrix reference material for use in marine environmental monitoring programs.
Böhlke, J.K.; Mroczkowski, S.J.; Coplen, T.B.
2003-01-01
Despite a rapidly growing literature on analytical methods and field applications of O isotope-ratio measurements of NO3− in environmental studies, there is evidence that the reported data may not be comparable because reference materials with widely varying δ18O values have not been readily available. To address this problem, we prepared large quantities of two nitrate salts with contrasting O isotopic compositions for distribution as reference materials for O isotope-ratio measurements: USGS34 (KNO3) with low δ18O and USGS35 (NaNO3) with high δ18O and ‘mass-independent’ δ17O. The procedure used to produce USGS34 involved equilibration of HNO3 with 18O-depleted meteoric water. Nitric acid equilibration is proposed as a simple method for producing laboratory NO3− reference materials with a range of δ18O values and normal (mass-dependent) 18O:17O:16O variation. Preliminary data indicate that the equilibrium O isotope-fractionation factor (α) between [NO3−] and H2O decreases with increasing temperature from 1.0215 at 22°C to 1.0131 at 100°C. USGS35 was purified from the nitrate ore deposits of the Atacama Desert in Chile and has a high 17O:18O ratio owing to its atmospheric origin. These new reference materials, combined with previously distributed NO3− isotopic reference materials IAEA-N3 (=IAEA-NO-3) and USGS32, can be used to calibrate local laboratory reference materials for determining offset values, scale factors, and mass-independent effects on N and O isotope-ratio measurements in a wide variety of environmental NO3− samples. Preliminary analyses yield the following results (normalized with respect to VSMOW and SLAP, with reproducibilities of ±0.2–0.3‰, 1σ): IAEA-N3 has δ18O = +25.6‰ and δ17O = +13.2‰; USGS32 has δ18O = +25.7‰; USGS34 has δ18O = −27.9‰ and δ17O = −14.8‰; and USGS35 has δ18O = +57.5‰ and δ17O = +51.5‰.
Preparation and Use of Polish Mushroom Proficiency Testing Materials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Polkowska-Motrenko, Halina
2008-08-14
Mushroom reference materials have been prepared and characterized for the use in proficiency tests according to a procedure established within the frame of an IAEA Interregional Technical Cooperation Project. The materials were used for conducting the proficiency tests in Poland in 2005-2007. The results obtained by participating laboratories are presented and discussed.
Schimmelmann, A.; Albertino, A.; Sauer, P.E.; Qi, H.; Molinie, R.; Mesnard, F.
2009-01-01
Accurate determinations of stable isotope ratios require a calibration using at least two reference materials with different isotopic compositions to anchor the isotopic scale and compensate for differences in machine slope. Ideally, the S values of these reference materials should bracket the isotopic range of samples with unknown S values. While the practice of analyzing two isotopically distinct reference materials is common for water (VSMOW-SLAP) and carbonates (NBS 19 and L-SVEC), the lack of widely available organic reference materials with distinct isotopic composition has hindered the practice when analyzing organic materials by elemental analysis/isotope ratio mass spectrometry (EA-IRMS). At present only L-glutamic acids USGS40 and USGS41 satisfy these requirements for ??13C and ??13N, with the limitation that L-glutamic acid is not suitable for analysis by gas chromatography (GC). We describe the development and quality testing of (i) four nicotine laboratory reference materials for on-line (i.e. continuous flow) hydrogen reductive gas chromatography-isotope ratio mass-spectrometry (GC-IRMS), (ii) five nicotines for oxidative C, N gas chromatography-combustion-isotope ratio mass-spectrometry (GC-C-IRMS, or GC-IRMS), and (iii) also three acetanilide and three urea reference materials for on-line oxidative EA-IRMS for C and N. Isotopic off-line calibration against international stable isotope measurement standards at Indiana University adhered to the 'principle of identical treatment'. The new reference materials cover the following isotopic ranges: ??2Hnicotine -162 to -45%o, ??13Cnicotine -30.05 to +7.72%, ?? 15Nnicotine -6.03 to +33.62%; ??15N acetanilide +1-18 to +40.57%; ??13Curea -34.13 to +11.71%, ??15Nurea +0.26 to +40.61% (recommended ?? values refer to calibration with NBS 19, L-SVEC, IAEA-N-1, and IAEA-N-2). Nicotines fill a gap as the first organic nitrogen stable isotope reference materials for GC-IRMS that are available with different ??13N values. Comparative ??13C and ??15N on-line EA-IRMS data from 14 volunteering laboratories document the usefulness and reliability of acetanilides and ureas as EA-IRMS reference materials.
On the status of IAEA delta-13C stable isotope reference materials.
NASA Astrophysics Data System (ADS)
Assonov, Sergey; Groening, Manfred; Fajgelj, Ales
2016-04-01
For practical reasons all isotope measurements are performed on relative scales realized through the use of international, scale-defining primary standards. In fact these standards were materials (artefacts, similar to prototypes of meter and kg) selected based on their properties. The VPDB delta-13C scale is realised via two highest-level reference materials NBS19 and LSVEC, the first defining the scale and the second aimed to normalise lab-to-lab calibrations. These two reference materials (RMs) have been maintained and distributed by IAEA and NIST. The priority task is to maintain these primary RMs at the required uncertainty level, thus ensuring the long-term scale consistency. The second task is to introduce replacements when needed (currently for exhausted NBS19, work in progress). The next is to produce a family of lower level RMs (secondary, tertiary) addressing needs of various applications (with different delta values, in different physical-chemical forms) and their needs for the uncertainty; these RMs should be traceable to the highest level RMs. Presently three is a need for a range of RMs addressing existing and newly emerging analytical techniques (e.g. optical isotopic analysers) in form of calibrated CO2 gases with different delta-13C values. All that implies creating a family of delta-13C stable isotope reference materials. Presently IAEA works on replacement for NBS19 and planning new RMs. Besides, we found that LSVEC (introduced as second anchor for the VPDB scale in 2006) demonstrate a considerable scatter of its delta-13C value which implies a potential bias of the property value and increased value uncertainty which may conflict with uncertainty requirements for atmospheric monitoring. That is not compatible with the status of LSVEC, and therefore it should be replaced as soon as possible. The presentation will give an overview of the current status, the strategic plan of developments and the near future steps.
δ15N measurement of organic and inorganic substances by EA-IRMS: a speciation-dependent procedure.
Gentile, Natacha; Rossi, Michel J; Delémont, Olivier; Siegwolf, Rolf T W
2013-01-01
Little attention has been paid so far to the influence of the chemical nature of the substance when measuring δ(15)N by elemental analysis (EA)-isotope ratio mass spectrometry (IRMS). Although the bulk nitrogen isotope analysis of organic material is not to be questioned, literature from different disciplines using IRMS provides hints that the quantitative conversion of nitrate into nitrogen presents difficulties. We observed abnormal series of δ(15)N values of laboratory standards and nitrates. These unexpected results were shown to be related to the tailing of the nitrogen peak of nitrate-containing compounds. A series of experiments were set up to investigate the cause of this phenomenon, using ammonium nitrate (NH(4)NO(3)) and potassium nitrate (KNO(3)) samples, two organic laboratory standards as well as the international secondary reference materials IAEA-N1, IAEA-N2-two ammonium sulphates [(NH(4))(2)SO(4)]-and IAEA-NO-3, a potassium nitrate. In experiment 1, we used graphite and vanadium pentoxide (V(2)O(5)) as additives to observe if they could enhance the decomposition (combustion) of nitrates. In experiment 2, we tested another elemental analyser configuration including an additional section of reduced copper in order to see whether or not the tailing could originate from an incomplete reduction process. Finally, we modified several parameters of the method and observed their influence on the peak shape, δ(15)N value and nitrogen content in weight percent of nitrogen of the target substances. We found the best results using mere thermal decomposition in helium, under exclusion of any oxygen. We show that the analytical procedure used for organic samples should not be used for nitrates because of their different chemical nature. We present the best performance given one set of sample introduction parameters for the analysis of nitrates, as well as for the ammonium sulphate IAEA-N1 and IAEA-N2 reference materials. We discuss these results considering the thermochemistry of the substances and the analytical technique itself. The results emphasise the difference in chemical nature of inorganic and organic samples, which necessarily involves distinct thermochemistry when analysed by EA-IRMS. Therefore, they should not be processed using the same analytical procedure. This clearly impacts on the way international secondary reference materials should be used for the calibration of organic laboratory standards.
Nuclear reference materials to meet the changing needs of the global nuclear community
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martin, H.R.; Gradle, C.G.; Narayanan, U.I.
New Brunswick Laboratory (NBL) serves as the U.S. Government`s certifying authority for nuclear reference materials and measurement calibration standards. In this role, NBL provides nuclear reference materials certified for chemical and/or isotopic compositions traceable to a nationally accepted, internationally compatible reference base. Emphasis is now changing as to the types of traceable nuclear reference materials needed as operations change within the Department of Energy complex and at nuclear facilities around the world. New challenges include: environmental and waste minimization issues, facilities and materials transitioning from processing to storage modes with corresponding changes in the types of measurements being performed, emphasismore » on requirements for characterization of waste materials, and difficulties in transporting nuclear materials and international factors, including IAEA influences. During these changing times, it is critical that traceable reference materials be provided for calibration or validation of the performance of measurement systems. This paper will describe actions taken and planned to meet the changing reference material needs of the global nuclear community.« less
10 CFR 75.24 - Retention of records.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 2 2011-01-01 2011-01-01 false Retention of records. 75.24 Section 75.24 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA AGREEMENT Material Accounting and Control for Facilities § 75.24 Retention of records. The records referred to in §§ 75.22 and...
10 CFR 75.24 - Retention of records.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 2 2010-01-01 2010-01-01 false Retention of records. 75.24 Section 75.24 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA AGREEMENT Material Accounting and Control for Facilities § 75.24 Retention of records. The records referred to in §§ 75.22 and...
Varga, Zsolt
2007-03-28
An improved and novel sample preparation method for (241)Am analysis by inductively coupled plasma sector field mass spectrometry has been developed. The procedure involves a selective CaF(2) pre-concentration followed by an extraction chromatographic separation using TRU resin. The achieved absolute detection limit of 0.86 fg (0.11 mBq) is comparable to that of alpha spectrometry (0.1 mBq) and suitable for low-level environmental measurements. Analysis of different kinds of environmental standard reference materials (IAEA-384--Fangataufa lagoon sediment, IAEA-385--Irish Sea sediment and IAEA-308--Mixed seaweed from the Mediterranean Sea) and alpha spectrometry were used to validate the procedure. The chemical recovery of sample preparation ranged between 72 and 94%. The results obtained are in good agreement with reference values and those measured by alpha spectrometry. The proposed method offers a rapid and less labor-intensive possibility for environmental (241)Am analysis than the conventionally applied radioanalytical techniques.
Coplen, T.B.; Qi, H.
2009-01-01
New isotope laboratories can achieve the goal of reporting the same isotopic composition within analytical uncertainty for the same material analysed decades apart by (1) writing their own acceptance testing procedures and putting them into their mass spectrometric or laser-based isotope-ratio equipment procurement contract, (2) requiring a manufacturer to demonstrate acceptable performance using all sample ports provided with the instrumentation, (3) for each medium to be analysed, prepare two local reference materials substantially different in isotopic composition to encompass the range in isotopic composition expected in the laboratory and calibrated them with isotopic reference materials available from the International Atomic Energy Agency (IAEA) or the US National Institute of Standards and Technology (NIST), (4) using the optimum storage containers (for water samples, sealing in glass ampoules that are sterilised after sealing is satisfactory), (5) interspersing among sample unknowns local laboratory isotopic reference materials daily (internationally distributed isotopic reference materials can be ordered at three-year intervals, and can be used for elemental analyser analyses and other analyses that consume less than 1 mg of material) - this process applies to H, C, N, O, and S isotope ratios, (6) calculating isotopic compositions of unknowns by normalising isotopic data to that of local reference materials, which have been calibrated to internationally distributed isotopic reference materials, (7) reporting results on scales normalised to internationally distributed isotopic reference materials (where they are available) and providing to sample submitters the isotopic compositions of internationally distributed isotopic reference materials of the same substance had they been analysed with unknowns, (8) providing an audit trail in the laboratory for analytical results - this trail commonly will be in electronic format and might include a laboratory information management system, (9) making at regular intervals a complete backup of laboratory analytical data (both of samples logged into the laboratory and of mass spectrometric analyses), being sure to store one copy of this backup offsite, and (10) participating in interlaboratory comparison exercises sponsored by the IAEA and other agencies at regular intervals. ?? Taylor & Francis.
Schimmelmann, Arndt; Albertino, Andrea; Sauer, Peter E; Qi, Haiping; Molinie, Roland; Mesnard, François
2009-11-01
Accurate determinations of stable isotope ratios require a calibration using at least two reference materials with different isotopic compositions to anchor the isotopic scale and compensate for differences in machine slope. Ideally, the delta values of these reference materials should bracket the isotopic range of samples with unknown delta values. While the practice of analyzing two isotopically distinct reference materials is common for water (VSMOW-SLAP) and carbonates (NBS 19 and L-SVEC), the lack of widely available organic reference materials with distinct isotopic composition has hindered the practice when analyzing organic materials by elemental analysis/isotope ratio mass spectrometry (EA-IRMS). At present only L-glutamic acids USGS40 and USGS41 satisfy these requirements for delta13C and delta15N, with the limitation that L-glutamic acid is not suitable for analysis by gas chromatography (GC). We describe the development and quality testing of (i) four nicotine laboratory reference materials for on-line (i.e. continuous flow) hydrogen reductive gas chromatography-isotope ratio mass-spectrometry (GC-IRMS), (ii) five nicotines for oxidative C, N gas chromatography-combustion-isotope ratio mass-spectrometry (GC-C-IRMS, or GC-IRMS), and (iii) also three acetanilide and three urea reference materials for on-line oxidative EA-IRMS for C and N. Isotopic off-line calibration against international stable isotope measurement standards at Indiana University adhered to the 'principle of identical treatment'. The new reference materials cover the following isotopic ranges: delta2H(nicotine) -162 to -45 per thousand, delta13C(nicotine) -30.05 to +7.72 per thousand, delta15N(nicotine) -6.03 to +33.62 per thousand; delta15N(acetanilide) +1.18 to +40.57 per thousand; delta13C(urea) -34.13 to +11.71 per thousand, delta15N(urea) +0.26 to +40.61 per thousand (recommended delta values refer to calibration with NBS 19, L-SVEC, IAEA-N-1, and IAEA-N-2). Nicotines fill a gap as the first organic nitrogen stable isotope reference materials for GC-IRMS that are available with different delta15N values. Comparative delta13C and delta15N on-line EA-IRMS data from 14 volunteering laboratories document the usefulness and reliability of acetanilides and ureas as EA-IRMS reference materials. Copyright 2009 John Wiley & Sons, Ltd.
Nuclear reference materials to meet the changing needs of the global nuclear community
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martin, H.R.; Gradle, C.G.; Narayanan, U.I.
New Brunswick Laboratory (NBL) serves as the US Government`s Certifying Authority for nuclear reference materials and measurement calibration standards. In this role, NBL provides nuclear reference materials certified for chemical and/or isotopic compositions traceable to a nationally accepted, internationally compatible reference base. Emphasis is now changing as to the types of traceable nuclear reference materials needed as operations change within the Department of Energy (DOE) complex and at nuclear facilities around the world. Environmental and waste minimization issues, facilities and materials transitioning from processing to storage modes with corresponding changes in the types of measurements being performed, emphasis on requirementsmore » for characterization of waste materials, difficulties in transporting nuclear materials, and International factors, including International Atomic Energy Agency (IAEA) inspection of excess US nuclear materials, are all contributing influences. During these changing times, ft is critical that traceable reference materials be provided for calibration or validation of the performance of measurement systems. This paper will describe actions taken and planned to meet the changing reference material needs of the global nuclear community.« less
Biomedical graphite and CaF2 preparation and measurement at PRIME Lab
NASA Astrophysics Data System (ADS)
Jackson, George S.; Einstein, Jane A.; Kubley, Tom; Martin, Berdine; Weaver, Connie M.; Caffee, Marc
2015-10-01
The biomedical program at PRIME Lab has prepared radiocarbon and 41Ca as tracers for a variety of applications. Over the last decade several hundred 14C samples and several thousand 41Ca samples have been measured per year. Biomedical samples pose challenges that are relatively rare in the AMS community. We will discuss how to prepare and compensate for samples that have isotope ratios above the dynamic range of AMS, high interference rates, and small samples sizes. In the case of 41Ca, the trade off in the chromatography between yield and sample cleanliness will be analyzed. Secondary standards that have isotope ratios commonly encountered in our applications are routinely prepared. We use material from the Joint Research Centre's Institute for Reference Materials and Measurement: IRMM-3701/4, 3701/5, and 3701/6 and a standard produced by PRIME Lab for 41Ca. We use International Atomic Energy Agency's IAEA C-3, IAEA C-7, IAEA C-8, and a ∼12.5× modern oxalic acid secondary standard supplied by Lawrence Livermore National Laboratory for 14C. We will discuss our precision, reproducibility, and the relative agreement between our measured and the reported values for these materials.
Ebongué, Véronique Woule; Geypens, Benny; Berglund, Michael; Taylor, Philip
2009-03-01
This work aims at comparing the delta(13)C(VPDB) of mono-aromatic hydrocarbons benzene, toluene, ethylbenzene and xylene isomers (BTEX) measured by elemental analyser (EA)-isotope ratio mass spectrometer (IRMS) with the delta(13)C(VPDB) measured on the same compounds by headspace solid phase microextraction - GC/C-IRMS (hSPME - GC/C-IRMS) with the final goal of using these compounds as internal standards on the latter system. The EA-IRMS measurements were done using calcium and lithium carbonate isotopic reference materials: NBS19 and L-SVEC for establishing the delta(13)C(VPDB) scale. The EA-IRMS measurements with helium dilution of a set of five reference materials (USGS40, USGS41, IAEA-CH-6, IAEA-CH-3 and IAEA-601) show systematic bias of 1 per thousand relative to their assigned values. This bias due to the dilution mechanism in the used ConfloII interface device could not be avoided. As the selected hydrocarbons: BTEX could not be analysed by EA-IRMS without helium dilution, their delta(13)C(VPDB) must be corrected from this observed bias using an external calibration. The CO(2) gas calibrated using EA-IRMS without helium dilution, was used as an in-house reference for the delta(13)C(VPDB) measurements of the BTEX by the hSPME - GC/C-IRMS system. The comparison made between the delta(13)C(VPDB) measured on the same BTEX compounds by EA-IRMS (with external calibration) and by hSPME - GC/C-IRMS techniques showed good agreement.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-01
... (IAEA) ``Regulations for the Safe Transport of Radioactive Material'' (TS-R-1), which is scheduled for... comments on the draft document to the IAEA. We are requesting input from the public to assist in developing....gov . SUPPLEMENTARY INFORMATION: I. Background The IAEA works with its Member States and multiple...
Treatment planning systems dosimetry auditing project in Portugal.
Lopes, M C; Cavaco, A; Jacob, K; Madureira, L; Germano, S; Faustino, S; Lencart, J; Trindade, M; Vale, J; Batel, V; Sousa, M; Bernardo, A; Brás, S; Macedo, S; Pimparel, D; Ponte, F; Diaz, E; Martins, A; Pinheiro, A; Marques, F; Batista, C; Silva, L; Rodrigues, M; Carita, L; Gershkevitsh, E; Izewska, J
2014-02-01
The Medical Physics Division of the Portuguese Physics Society (DFM_SPF) in collaboration with the IAEA, carried out a national auditing project in radiotherapy, between September 2011 and April 2012. The objective of this audit was to ensure the optimal usage of treatment planning systems. The national results are presented in this paper. The audit methodology simulated all steps of external beam radiotherapy workflow, from image acquisition to treatment planning and dose delivery. A thorax CIRS phantom lend by IAEA was used in 8 planning test-cases for photon beams corresponding to 15 measuring points (33 point dose results, including individual fields in multi-field test cases and 5 sum results) in different phantom materials covering a set of typical clinical delivery techniques in 3D Conformal Radiotherapy. All 24 radiotherapy centers in Portugal have participated. 50 photon beams with energies 4-18 MV have been audited using 25 linear accelerators and 32 calculation algorithms. In general a very good consistency was observed for the same type of algorithm in all centres and for each beam quality. The overall results confirmed that the national status of TPS calculations and dose delivery for 3D conformal radiotherapy is generally acceptable with no major causes for concern. This project contributed to the strengthening of the cooperation between the centres and professionals, paving the way to further national collaborations. Copyright © 2013 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Olson, John; Adamic, Mary; Snyder, Darin
Iodine environmental measurements have consistently been backed up in the literature by standard materials like IAEA-375, Chernobyl Soil. There are not many other sources of a certified reference material for 129I content for mass spectrometry measurements. Some that have been found in the literature include NIST-4354 and NIST-4357. They are still available at the time of this writing. They don’t have certified content or isotopic values. There has been some work in the literature to show that iodine is present, but there hasn’t been enough to establish a consensus value. These materials have been analyzed at INL through two separatemore » mass spectrometry techniques. They involve a combustion method of the starting material in oxygen, followed by TIMS analysis and a leaching preparation analyzed by accelerator mass spectrometry. Combustion/TIMS preparation of NIST SRM-4354 resulted in a 129I/127I ratio of 1.92 x 10-6 which agrees with AMS measurements which measured the 129I/127I ratio to be 1.93 x 10-6.« less
10 CFR 75.12 - Communication of information to IAEA.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 2 2010-01-01 2010-01-01 false Communication of information to IAEA. 75.12 Section 75.12 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA AGREEMENT Facility and Location Information § 75.12 Communication of information to IAEA. (a) Except as...
10 CFR 75.12 - Communication of information to IAEA.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 2 2011-01-01 2011-01-01 false Communication of information to IAEA. 75.12 Section 75.12 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA AGREEMENT Facility and Location Information § 75.12 Communication of information to IAEA. (a) Except as...
10 CFR 75.7 - Notification of IAEA safeguards.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 2 2011-01-01 2011-01-01 false Notification of IAEA safeguards. 75.7 Section 75.7 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA AGREEMENT General Provisions § 75.7 Notification of IAEA safeguards. (a) The licensee must inform the NRC...
10 CFR 75.7 - Notification of IAEA safeguards.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 2 2010-01-01 2010-01-01 false Notification of IAEA safeguards. 75.7 Section 75.7 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA AGREEMENT General Provisions § 75.7 Notification of IAEA safeguards. (a) The licensee must inform the NRC...
Method to determine 226Ra in small sediment samples by ultralow background liquid scintillation.
Sanchez-Cabeza, Joan-Albert; Kwong, Laval Liong Wee; Betti, Maria
2010-08-15
(210)Pb dating of sediment cores is a widely used tool to reconstruct ecosystem evolution and historical pollution during the last century. Although (226)Ra can be determined by gamma spectrometry, this method shows severe limitations which are, among others, sample size requirements and counting times. In this work, we propose a new strategy based on the analysis of (210)Pb through (210)Po in equilibrium by alpha spectrometry, followed by the determination of (226)Ra (base or supported (210)Pb) without any further chemical purification by liquid scintillation and with a higher sample throughput. Although gamma spectrometry might still be required to determine (137)Cs as an independent tracer, the effort can then be focused only on those sections dated around 1963, when maximum activities are expected. In this work, we optimized the counting conditions, calibrated the system for changing quenching, and described the new method to determine (226)Ra in small sediment samples, after (210)Po determination, allowing a more precise determination of excess (210)Pb ((210)Pb(ex)). The method was validated with reference materials IAEA-384, IAEA-385, and IAEA-313.
Experimental validation of beam quality correction factors for proton beams
NASA Astrophysics Data System (ADS)
Gomà, Carles; Hofstetter-Boillat, Bénédicte; Safai, Sairos; Vörös, Sándor
2015-04-01
This paper presents a method to experimentally validate the beam quality correction factors (kQ) tabulated in IAEA TRS-398 for proton beams and to determine the kQ of non-tabulated ionization chambers (based on the already tabulated values). The method is based exclusively on ionometry and it consists in comparing the reading of two ionization chambers under the same reference conditions in a proton beam quality Q and a reference beam quality 60Co. This allows one to experimentally determine the ratio between the kQ of the two ionization chambers. In this work, 7 different ionization chamber models were irradiated under the IAEA TRS-398 reference conditions for 60Co beams and proton beams. For the latter, the reference conditions for both modulated beams (spread-out Bragg peak field) and monoenergetic beams (pseudo-monoenergetic field) were studied. For monoenergetic beams, it was found that the experimental kQ values obtained for plane-parallel chambers are consistent with the values tabulated in IAEA TRS-398; whereas the kQ values obtained for cylindrical chambers are not consistent—being higher than the tabulated values. These results support the suggestion (of previous publications) that the IAEA TRS-398 reference conditions for monoenergetic proton beams should be revised so that the effective point of measurement of cylindrical ionization chambers is taken into account when positioning the reference point of the chamber at the reference depth. For modulated proton beams, the tabulated kQ values of all the ionization chambers studied in this work were found to be consistent with each other—except for the IBA FC65-G, whose experimental kQ value was found to be 0.6% lower than the tabulated one. The kQ of the PTW Advanced Markus chamber, which is not tabulated in IAEA TRS-398, was found to be 0.997 ± 0.042 (k = 2), based on the tabulated value of the PTW Markus chamber.
Merk, Rainer
2012-02-01
This study depicts a theoretical experiment in which the radionuclide transport through the porous material of a landfill consisting of concrete rubble (e.g., from the decommissioning of nuclear power plants) and the subsequent migration through the vadose zone and aquifer to a model well is calculated by means of the software HYDRUS-1D (Simunek et al., 2008). The radionuclides originally contained within the rubble become dissolved due to leaching caused by infiltrated rainwater. The resulting well-water contamination (in Bq/L) is calculated numerically as a function of time and location and compared with the outcome of a simplified analytic model for the groundwater pathway published by the IAEA (2005). Identical model parameters are considered. The main objective of the present work is to evaluate the predictive capacity of the more simple IAEA model using HYDRUS-1D as a reference. For most of the radionuclides considered (e.g., ¹²⁹I, and ²³⁹Pu), results from applying the IAEA model were found to be comparable to results from the more elaborate HYDRUS modeling, provided the underlying parameter values are comparable. However, the IAEA model appears to underestimate the effects resulting from, for example, high nuclide mobility, short half-life, or short-term variations in the water infiltration. The present results indicate that the IAEA model is suited for screening calculations and general recommendation purposes. However, the analysis of a specific site should be accompanied by detailed HYDRUS computer simulations. In all models considered, the calculation outcome largely depends on the choice of the sorption parameter K(d). Copyright © 2011 Elsevier Ltd. All rights reserved.
Krata, Agnieszka; Vassileva, Emilia; Bulska, Ewa
2016-11-01
The analytical procedures for reference measurements of the total Hg and methyl mercury (MeHg) mass fractions at various concentration levels in marine biota samples, candidates for certified reference materials (oyster and clam Gafrarium tumidum), were evaluated. Two modes of application of isotope dilution inductively coupled plasma mass spectrometry method (ID ICP-MS), namely direct isotope dilution and species-specific isotope dilution analysis with the use of two different quantification mass spectrometry techniques were compared. The entire ID ICP-MS measurement procedure was described by mathematical modelling and the combined uncertainty of measurement results was estimated. All factors influencing the final results as well as isotopic equilibrium were systematically investigated. This included the procedural blank, the moisture content in the biota samples and all factors affecting the blend ratio measurements (instrumental background, spectral interferences, dead time and mass discrimination effects as well as the repeatability of measured isotopic ratios). Modelling of the entire measurement procedures and the use of appropriate certified reference materials enable to assure the traceability of obtained values to the International System of Units (SI): the mole or the kilogram. The total mass fraction of mercury in oyster and clam biota samples, after correction for moisture contents, was found to be: 21.1 (1.1) 10(-9) kg kg(-1) (U =5.1% relative, k=2) and 390.0 (9.4) 10(-9) kg kg(-1) (U=2.4% relative, k=2), respectively. For the determination of mercury being present as methyl mercury, the non-chromatographic separation on anion-exchange resin AG1-X8 of the blended samples was applied. The content of MeHg (as Hg) in oyster sample was found: 4.81 (24) 10(-9)kgkg(-1) (U=5.0%, k=2) and 4.84 (21) 10(-9)kgkg(-1) (U=4.3%, k=2) with the use of quadrupole (ICP QMS) or sector field (ICP SFMS) inductively coupled plasma mass spectrometers, respectively. In the case of clam sample, the concentration of MeHg (as Hg) was found to be: 61.0 (2.3) 10(-)(9)kgkg(-1) (U=3.8%, k=2) and 61.3 (2.2) 10(-)(9)kgkg(-1) (U=3.6%, k=2), respectively. The mass fractions for total Hg and MeHg determined in this study were used as a contribution of the International Atomic Energy Agency (IAEA) Environment Laboratories in the characterisation of the IAEA 461 and IAEA 470 certified reference materials. The obtained good agreement with the reference values further validated the methods developed in this study. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Mann, J. L.; Kelly, W. R.
2006-05-01
A new analytical technique for the determination of δ34S will be described. The technique is based on the production of singularly charged arsenic sulfide molecular ions (AsS+) by thermal ionization using silica gel as an emitter and combines multiple-collector thermal ionization mass spectrometry (MC-TIMS) with a 33S/36S double spike to correct instrumental fractionation. Because the double spike is added to the sample before chemical processing, both the isotopic composition and sulfur concentration are measured simultaneously. The accuracy and precision of the double spike technique is comparable to or better than modern gas source mass spectrometry, but requires about a factor of 10 less sample. Δ33S effects can be determined directly in an unspiked sample without any assumptions about the value of k (mass dependent fractionation factor) which is currently required by gas source mass spectrometry. Three international sulfur standards (IAEA-S-1, IAEA-S-2, and IAEA-S-3) were measured to evaluate the precision and accuracy of the new technique and to evaluate the consensus values for these standards. Two different double spike preparations were used. The δ34S values (reported relative to Vienna Canyon Diablo Troilite (VCDT), (δ34S (‰) = 34S/32S)sample/(34S/32S)VCDT - 1) x 1000]), 34S/32SVCDT = 0.0441626) determined were -0.32‰ ± 0.04‰ (1σ, n=4) and -0.31‰ ± 0.13‰ (1σ, n=8) for IAEA-S-1, 22.65‰ ± 0.04‰ (1σ, n=7) and 22.60‰ ± 0.06‰ (1σ, n=5) for IAEA- S-2, and -32.47‰ ± 0.07‰ (1σ, n=8) for IAEA-S-3. The amount of natural sample used for these analyses ranged from 0.40 μmoles to 2.35 μmoles. Each standard showed less than 0.5‰ variability (IAEA-S-1 < 0.4‰, IAEA-S-2 < 0.2‰, and IAEA-S-3 < 0.2‰). Our values for S-1 and S-2 are in excellent agreement with the consensus values and the values reported by other laboratories using both SF6 and SO2. Our value for S-3 differs statistically from the Institute for Reference Materials and Measurement (IRMM) value and is slightly lower than the currently accepted consensus value (-32.3). Because the technique is based on thermal ionization of AsS+, and As is mononuclidic, corrections for interferences or for scale contraction/expansion are not required. The availability of MC-TIMS instruments in laboratories around the world makes this technique immediately available to a much larger scientific community who require highly accurate and precise measurements of sulfur.
Izewska, Joanna; Georg, Dietmar; Bera, Pranabes; Thwaites, David; Arib, Mehenna; Saravi, Margarita; Sergieva, Katia; Li, Kaibao; Yip, Fernando Garcia; Mahant, Ashok Kumar; Bulski, Wojciech
2007-07-01
A strategy for national TLD audit programmes has been developed by the International Atomic Energy Agency (IAEA). It involves progression through three sequential dosimetry audit steps. The first step audits are for the beam output in reference conditions for high-energy photon beams. The second step audits are for the dose in reference and non-reference conditions on the beam axis for photon and electron beams. The third step audits involve measurements of the dose in reference, and non-reference conditions off-axis for open and wedged symmetric and asymmetric fields for photon beams. Through a co-ordinated research project the IAEA developed the methodology to extend the scope of national TLD auditing activities to more complex audit measurements for regular fields. Based on the IAEA standard TLD holder for high-energy photon beams, a TLD holder was developed with horizontal arm to enable measurements 5cm off the central axis. Basic correction factors were determined for the holder in the energy range between Co-60 and 25MV photon beams. New procedures were developed for the TLD irradiation in hospitals. The off-axis measurement methodology for photon beams was tested in a multi-national pilot study. The statistical distribution of dosimetric parameters (off-axis ratios for open and wedge beam profiles, output factors, wedge transmission factors) checked in 146 measurements was 0.999+/-0.012. The methodology of TLD audits in non-reference conditions with a modified IAEA TLD holder has been shown to be feasible.
Schimmelmann, Arndt; Qi, Haiping; Coplen, Tyler B; Brand, Willi A; Fong, Jon; Meier-Augenstein, Wolfram; Kemp, Helen F; Toman, Blaza; Ackermann, Annika; Assonov, Sergey; Aerts-Bijma, Anita T; Brejcha, Ramona; Chikaraishi, Yoshito; Darwish, Tamim; Elsner, Martin; Gehre, Matthias; Geilmann, Heike; Gröning, Manfred; Hélie, Jean-François; Herrero-Martín, Sara; Meijer, Harro A J; Sauer, Peter E; Sessions, Alex L; Werner, Roland A
2016-04-19
An international project developed, quality-tested, and determined isotope-δ values of 19 new organic reference materials (RMs) for hydrogen, carbon, and nitrogen stable isotope-ratio measurements, in addition to analyzing pre-existing RMs NBS 22 (oil), IAEA-CH-7 (polyethylene foil), and IAEA-600 (caffeine). These new RMs enable users to normalize measurements of samples to isotope-δ scales. The RMs span a range of δ(2)H(VSMOW-SLAP) values from -210.8 to +397.0 mUr or ‰, for δ(13)C(VPDB-LSVEC) from -40.81 to +0.49 mUr and for δ(15)N(Air) from -5.21 to +61.53 mUr. Many of the new RMs are amenable to gas and liquid chromatography. The RMs include triads of isotopically contrasting caffeines, C16 n-alkanes, n-C20-fatty acid methyl esters (FAMEs), glycines, and l-valines, together with polyethylene powder and string, one n-C17-FAME, a vacuum oil (NBS 22a) to replace NBS 22 oil, and a (2)H-enriched vacuum oil. A total of 11 laboratories from 7 countries used multiple analytical approaches and instrumentation for 2-point isotopic normalization against international primary measurement standards. The use of reference waters in silver tubes allowed direct normalization of δ(2)H values of organic materials against isotopic reference waters following the principle of identical treatment. Bayesian statistical analysis yielded the mean values reported here. New RMs are numbered from USGS61 through USGS78, in addition to NBS 22a. Because of exchangeable hydrogen, amino acid RMs currently are recommended only for carbon- and nitrogen-isotope measurements. Some amino acids contain (13)C and carbon-bound organic (2)H-enrichments at different molecular sites to provide RMs for potential site-specific isotopic analysis in future studies.
Schimmelmann, Arndt; Qi, Haiping; Coplen, Tyler B.; Brand, Willi A.; Fong, Jon; Meier-Augenstein, Wolfram; Kemp, Helen F.; Toman, Blaza; Ackermann, Annika; Assonov, Sergey; Aerts-Bijma, Anita; Brejcha, Ramona; Chikaraishi, Yoshito; Darwish, Tamim; Elsner, Martin; Gehre, Matthias; Geilmann, Heike; Gröning, Manfred; Hélie, Jean-François; Herrero-Martín, Sara; Meijer, Harro A.J.; Sauer, Peter E.; Sessions, Alex L.; Werner, Roland A.
2016-01-01
An international project developed, quality-tested, and determined isotope−δ values of 19 new organic reference materials (RMs) for hydrogen, carbon, and nitrogen stable isotope-ratio measurements, in addition to analyzing pre-existing RMs NBS 22 (oil), IAEA-CH-7 (polyethylene foil), and IAEA-600 (caffeine). These new RMs enable users to normalize measurements of samples to isotope−δ scales. The RMs span a range of δ2HVSMOW-SLAP values from −210.8 to +397.0 mUr or ‰, for δ13CVPDB-LSVEC from −40.81 to +0.49 mUr and for δ15NAir from −5.21 to +61.53 mUr. Many of the new RMs are amenable to gas and liquid chromatography. The RMs include triads of isotopically contrasting caffeines, C16 n-alkanes, n-C20-fatty acid methyl esters (FAMEs), glycines, and l-valines, together with polyethylene powder and string, one n-C17-FAME, a vacuum oil (NBS 22a) to replace NBS 22 oil, and a 2H-enriched vacuum oil. A total of 11 laboratories from 7 countries used multiple analytical approaches and instrumentation for 2-point isotopic normalization against international primary measurement standards. The use of reference waters in silver tubes allowed direct normalization of δ2H values of organic materials against isotopic reference waters following the principle of identical treatment. Bayesian statistical analysis yielded the mean values reported here. New RMs are numbered from USGS61 through USGS78, in addition to NBS 22a. Because of exchangeable hydrogen, amino acid RMs currently are recommended only for carbon- and nitrogen-isotope measurements. Some amino acids contain 13C and carbon-bound organic 2H-enrichments at different molecular sites to provide RMs for potential site-specific isotopic analysis in future studies.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 2 2010-01-01 2010-01-01 false Purpose. 75.1 Section 75.1 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA AGREEMENT General Provisions... under these US/IAEA Safeguards treaties. These obligations include providing information to the IAEA on...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 2 2011-01-01 2011-01-01 false Purpose. 75.1 Section 75.1 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA AGREEMENT General Provisions... under these US/IAEA Safeguards treaties. These obligations include providing information to the IAEA on...
40 CFR 418.41 - Specialized definitions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Ammonium Nitrate Subcategory § 418.41 Specialized... product shall mean the 100 percent ammonium nitrate content of the material manufactured. (Sec. 306(b...
40 CFR 418.41 - Specialized definitions.
Code of Federal Regulations, 2012 CFR
2012-07-01
... AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Ammonium Nitrate Subcategory § 418.41.... (b) The term product shall mean the 100 percent ammonium nitrate content of the material manufactured...
40 CFR 418.41 - Specialized definitions.
Code of Federal Regulations, 2014 CFR
2014-07-01
... STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Ammonium Nitrate Subcategory § 418.41 Specialized... product shall mean the 100 percent ammonium nitrate content of the material manufactured. (Sec. 306(b...
40 CFR 418.41 - Specialized definitions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Ammonium Nitrate Subcategory § 418.41 Specialized... product shall mean the 100 percent ammonium nitrate content of the material manufactured. (Sec. 306(b...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rosenthal, M.D.; Saum-Manning, L.; Houck, F.
Events in Iraq at the beginning of the 1990s demonstrated that the safeguards system of the International Atomic Energy Agency (IAEA) needed to be improved. It had failed, after all, to detect Iraq's clandestine nuclear weapon program even though some of Iraq's's activities had been pursued at inspected facilities in buildings adjacent to ones being inspected by the IAEA. Although there were aspects of the implementation of safeguards where the IAEA needed to improve, the primary limitations were considered to be part of the safeguards system itself. That system was based on the Nuclear Nonproliferation Treaty of 1970, to whichmore » Iraq was a party, and implemented on the basis of a model NPT safeguards agreement, published by the IAEA 1972 as INFCIRC/153 (corrected). The agreement calls for states to accept and for the IAEA to apply safeguards to all nuclear material in the state. Iraq was a party to such an agreement, but it violated the agreement by concealing nuclear material and other nuclear activities from the IAEA. Although the IAEA was inspecting in Iraq, it was hindered by aspects of the agreement that essentially limited its access to points in declared facilities and provided the IAEA with little information about nuclear activities anywhere else in Iraq. As a result, a major review of the NPT safeguards system was initiated by its Director General and Member States with the objective of finding the best means to enable the IAEA to detect both diversions from declared stocks and any undeclared nuclear material or activities in the state. Significant improvements that could be made within existing legal authority were taken quickly, most importantly a change in 1992 in how and when and what design information would be reported to the IAEA. During 1991-1996, the IAEA pursued intensive study, legal and technical analysis, and field trials and held numerous consultations with Member States. The Board of Governors discussed the issue of strengthening safeguards at almost all of its meeting.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Geist, William H.
2017-09-15
The objectives for this presentation are to describe the method that the IAEA uses to determine a sampling plan for nuclear material measurements; describe the terms detection probability and significant quantity; list the three nuclear materials measurement types; describe the sampling method applied to an item facility; and describe multiple method sampling.
10 CFR 75.33 - Accounting reports.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 2 2011-01-01 2011-01-01 false Accounting reports. 75.33 Section 75.33 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA AGREEMENT Reports § 75.33 Accounting reports. (a)(1) The accounting reports for each IAEA material balance area must...
10 CFR 75.33 - Accounting reports.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 2 2010-01-01 2010-01-01 false Accounting reports. 75.33 Section 75.33 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA AGREEMENT Reports § 75.33 Accounting reports. (a)(1) The accounting reports for each IAEA material balance area must...
Olson, John; Adamic, Mary; Snyder, Darin; Brookhart, Jacob; Hahn, Paula; Watrous, Matthew
2017-08-01
Iodine environmental measurements have consistently been validated in the literature using the standard material IAEA-375, soil collected approximately 160 miles northeast of Chernobyl, which is currently the only soil/sediment material with a certified 129 I activity. IAEA-375 has not been available for purchase since approximately 2010. Two other standard materials that are available (NIST SRM 4354, freshwater lake sediment and NIST SRM 4357, ocean sediment) have certified activities for a variety of radionuclides but not for 129 I. This paper reports a comparison of TIMS and AMS data for all three standards. Copyright © 2017. Published by Elsevier Ltd.
25 Years of Teamwork for Adult Education in Iowa.
ERIC Educational Resources Information Center
Stacy, W. H.
This silver anniversary report reviews the history of the Iowa Adult Education Association (IAEA) since its founding on April 7, 1945. IAEA conferences, meetings, workshops, and publications are covered year by year, with particular reference to such activities and concerns as leadership training, professional continuing education, educational…
76 FR 24854 - Proposed Information Collection; Comment Request; Additional Protocol Report Forms
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-03
... States to submit declaration forms to the International Atomic Energy Agency (IAEA) on a number of... purposes, but also would be necessary elements for a nuclear weapons program. These forms provides the IAEA... and milling of nuclear materials; buildings on sites of facilities selected by the IAEA from the U.S...
Exploratory study on potential safeguards applications for shared ledger technology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Frazar, Sarah L.; Jarman, Kenneth D.; Joslyn, Cliff A.
The International Atomic Energy Agency (IAEA) is responsible for providing credible assurance that countries are meeting their obligations not to divert or misuse nuclear materials and facilities for non-peaceful purposes. To this end, the IAEA integrates information about States’ nuclear material inventories and transactions with other types of data to draw its safeguards conclusions. As the amount and variety of data and information has increased, the IAEA’s data acquisition, management, and analysis processes have greatly benefited from advancements in computer science, data management, and cybersecurity during the last 20 years. Despite these advancements, inconsistent use of advanced computer technologies asmore » well as political concerns among certain IAEA Member States centered on trust, transparency, and IAEA authorities limit the overall effectiveness and efficiency of IAEA safeguards. As a result, there is an ongoing need to strengthen the effectiveness and efficiency of IAEA safeguards while improving Member State cooperation and trust in the safeguards system. These chronic safeguards needs could be met with some emerging technologies, specifically those associated with the digital currency bitcoin.« less
The Elemental Analysis of Biological and Environmental Materials Using a 2MEV Proton Beam
NASA Astrophysics Data System (ADS)
Arshed, Waheed
Available from UMI in association with The British Library. A programme has been developed to simulate the proton induced x-ray emission (PIXE) spectra and its uses have been described. The PIXE technique has been applied to the analysis of new biological reference materials which consist of IAEA human diet samples and NIST leaf samples. Homogeneity of these and two existing reference materials, IAEA soil -7 and Bowen's kale, has also been determined at the mug scale. A subsample representative of a material is ascertained by determination of sampling factors for the elements detected in the material. Proton induced gamma-ray emission (PIGE) analysis in conjunction with PIXE has been employed to investigate F and other elemental concentrations found in human teeth samples. The mean F concentration in enamel and dentine parts of teeth followed an age dependent model. Concentrations of Ca and P were found to be higher in the enamel than in the dentine. Analysis of blood and its components in the study of elemental models in sickle cell disease in Nigerians has been carried out. Comparisons revealed that Cl, Ca and Cu were at higher levels whereas K, Fe, Zn and Rb were at lower levels in the whole blood of the sicklers compared to controls. Similar results were obtained for the erythrocytes except that Br was found at higher concentration in erythrocytes of the sicklers. Higher concentrations of Cl, K, Fe and Cu were also observed in plasma of the sicklers compared to controls. PIXE and scanning electron microscopy (SEM) were used in the characterization of the Harmattan dust particulates collected at Kano and Ife. Most of the elements were found to be at higher concentrations as compared to those found in Recife (Brazil) and Toronto (Canada). The value of total suspended particulate was above the relevant national air quality standards. PIXE in conjunction with Rutherford backscattering spectrometry and instrumental neutron activation analysis was employed in the analysis of soil samples detecting 31 elements. The results have been discussed with reference to elemental concentrations and Ca/Si ratio. The latter was a valid indicator of soil pollution by the cement dust. (Abstract shortened by UMI.).
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-16
... Guidance for Aggregation of Sources NRC supports the use of the International Atomic Energy Agency's (IAEA) source categorization methodology as defined in IAEA Safety Standards Series No. RS-G-1.9, ``Categorization of Radioactive Sources,'' (2005) (see http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web...
Hunsinger, Glendon B; Stern, Libby A
2012-03-15
The use of high-temperature conversion (HTC) reduction systems interfaced with isotope ratio mass spectrometers for δ(18)O measurements of nitrogen-containing organic materials is complicated by isobaric interference from (14)N(16)O(+). This ion is produced in the ion source when N(2) reacts with trace oxygen shifting the m/z 30 baseline prior to elution of CO. We compared adaptations to a typical HTC system (TC/EA) to determine the best method to measure the δ(18)O values of nitrogen-rich organic substrates including: (1) 0.6 and 1.5 m 5 Å molecular sieve GC columns; (2) reduction of N(2) peak via He dilution; and (3) diversion of N(2) to waste via an automated four-port valve. These methods were applied to caffeine (IAEA-600), glycine, 4-nitroacetanilide, pentaerythritol tetranitrate (PETN) and cyclotrimethylene trinitramine (RDX), as well as pure and sodium azide-doped benzoic acid (IAEA-601) and sucrose (IAEA-CH6). The efficiency of N(2) production in the HTC interface was highly variable among these compounds. Both the longer column and the dilutor improved, but did not eliminate, the adverse effects of nitrogen. The diversion of N(2) adequately addressed the nitrogen-induced problems as indicated by: (1) consistent m/z 30 background offset between reference and sample CO for both N-free and N-rich materials; (2) production of the highest δ(18)O values; and (3) high correlation between the increase in the δ(18)O values relative to the GC-only measurements and the N(2) peak area. Additional validation would require N-rich oxygen isotope standards for inter-laboratory comparisons. Further, more stringent methodology may improve the poor inter-laboratory δ(18)O reproducibility of IAEA-600. Published in 2012 by John Wiley & Sons, Ltd.
Diffusivities of Ag, Cs, Sr, and Kr in TRISO fuel particles and graphite
DOE Office of Scientific and Technical Information (OSTI.GOV)
Collin, Blaise Paul
Tri-structural isotropic (TRISO) coated particles have been developed and studied since the late 1950s when the concept of coated particles was invented by Roy Huddle of the United Kingdom Atomic Energy Authority. Several decades of work by half a dozen countries on fission product transport in TRISO fuel through numerous irradiation and heating experiments have led to several recommendations of transport data and to the adoption of various sets of diffusion coefficients. In 1997, the International Atomic Energy Agency (IAEA) gathered all these historical results and issued a technical document (TECDOC-978 [IAEA]) that summarizes these sets of recommended diffusion coefficients.more » Table 1 shows the reference literature articles for the diffusivities that have historically been recommended by the American and German TRISO fuel development programs and that are summarized in the IAEA report (see section 7 for full references of these articles).« less
Elemental investigation of Syrian medicinal plants using PIXE analysis
NASA Astrophysics Data System (ADS)
Rihawy, M. S.; Bakraji, E. H.; Aref, S.; Shaban, R.
2010-09-01
Particle induced X-ray emission (PIXE) technique has been employed to perform elemental analysis of K, Ca, Mn, Fe, Cu, Zn, Br and Sr for Syrian medicinal plants used traditionally to enhance the body immunity. Plant samples were prepared in a simple dried base. The results were verified by comparing with those obtained from both IAEA-359 and IAEA-V10 reference materials. Relative standard deviations are mostly within ±5-10% suggest good precision. A correlation between the elemental content in each medicinal plant with its traditional remedial usage has been proposed. Both K and Ca are found to be the major elements in the samples. Fe, Mn and Zn have been detected in good levels in most of these plants clarifying their possible contribution to keep the body immune system in good condition. The contribution of the elements in these plants to the dietary recommended intakes (DRI) has been evaluated. Advantages and limitations of PIXE analytical technique in this investigation have been reviewed.
Comparison of δ18O measurements in nitrate by different combustion techniques
Revesz, Kinga; Böhlke, John Karl
2002-01-01
Three different KNO3 salts with δ18O values ranging from about −31 to +54‰ relative to VSMOW were used to compare three off-line, sealed glass tube combustion methods (widely used for isotope studies) with a more recently developed on-line carbon combustion technique. All methods yielded roughly similar isotope ratios for KNO3 samples with δ18O values in the midpoint of the δ18O scale near that of the nitrate reference material IAEA-NO-3 (around +21 to +25‰). This reference material has been used previously for one-point interlaboratory and intertechnique calibrations. However, the isotope ratio scale factors by all of the off-line combustion techniques are compressed such that they are between 0.3 and 0.7 times that of the on-line combustion technique. The contraction of the δ18O scale in the off-line preparations apparently is caused by O isotope exchange between the sample and the glass combustion tubes. These results reinforce the need for nitrate reference materials with δ18O values far from that of atmospheric O2, to improve interlaboratory comparability.
Proposal for Monitoring Within the Centrifuge Cascades of Uranium Enrichment Facilities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Farrar, David R.
2017-04-01
Safeguards are technical measures implemented by the International Atomic Energy Agency (IAEA) to independently verify that nuclear material is not diverted from peaceful purposes to weapons (IAEA, 2017a). Safeguards implemented at uranium enrichment facilities (facilities hereafter) include enrichment monitors (IAEA, 2011). Figure 1 shows a diagram of how a facility could be monitored. The use of a system for monitoring within centrifuge cascades is proposed.
Coordinated Research Projects of the IAEA Atomic and Molecular Data Unit
NASA Astrophysics Data System (ADS)
Braams, B. J.; Chung, H.-K.
2011-05-01
The IAEA Atomic and Molecular Data Unit is dedicated to the provision of databases for atomic, molecular and plasma-material interaction (AM/PMI) data that are relevant for nuclear fusion research. IAEA Coordinated Research Projects (CRPs) are the principal mechanism by which the Unit encourages data evaluation and the production of new data. Ongoing and planned CRPs on AM/PMI data are briefly described here.
Safeguards-by-Design:Guidance for High Temperature Gas Reactors (HTGRs) With Prismatic Fuel
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mark Schanfein; Casey Durst
2012-11-01
Introduction and Purpose The following is a guidance document from a series prepared for the U.S. Department of Energy (DOE) National Nuclear Security Administration (NNSA), under the Next Generation Safeguards Initiative (NGSI), to assist facility designers and operators in implementing international Safeguards-by-Design (SBD). SBD has two main objectives: (1) to avoid costly and time consuming redesign work or retrofits of new nuclear fuel cycle facilities and (2) to make the implementation of international safeguards more effective and efficient at such facilities. In the long term, the attainment of these goals would save industry and the International Atomic Energy Agency (IAEA)more » time, money, and resources and be mutually beneficial. This particular safeguards guidance document focuses on prismatic fuel high temperature gas reactors (HTGR). The purpose of the IAEA safeguards system is to provide credible assurance to the international community that nuclear material and other specified items are not diverted from peaceful nuclear uses. The safeguards system consists of the IAEA’s statutory authority to establish safeguards; safeguards rights and obligations in safeguards agreements and additional protocols; and technical measures implemented pursuant to those agreements. Of foremost importance is the international safeguards agreement between the country and the IAEA, concluded pursuant to the Treaty on the Non-Proliferation of Nuclear Weapons (NPT). According to a 1992 IAEA Board of Governors decision, countries must: notify the IAEA of a decision to construct a new nuclear facility as soon as such decision is taken; provide design information on such facilities as the designs develop; and provide detailed design information based on construction plans at least 180 days prior to the start of construction, and on "as-built" designs at least 180 days before the first receipt of nuclear material. Ultimately, the design information will be captured in an IAEA Design Information Questionnaire (DIQ), prepared by the facility operator, typically with the support of the facility designer. The IAEA will verify design information over the life of the project. This design information is an important IAEA safeguards tool. Since the main interlocutor with the IAEA in each country is the State Regulatory Authority/SSAC (or Regional Regulatory Authority, e.g. EURATOM), the responsibility for conveying this design information to the IAEA falls to the State Regulatory Authority/SSAC. For the nuclear industry to reap the benefits of SBD (i.e. avoid cost overruns and construction schedule slippages), nuclear facility designers and operators should work closely with the State Regulatory Authority and IAEA as soon as a decision is taken to build a new nuclear facility. Ideally, this interaction should begin during the conceptual design phase and continue throughout construction and start-up of a nuclear facility. Such early coordination and planning could influence decisions on the design of the nuclear material processing flow-sheet, material storage and handling arrangements, and facility layout (including safeguards equipment), etc.« less
NASA Astrophysics Data System (ADS)
Acharya, R.; Swain, K. K.; Reddy, A. V. R.
2010-10-01
Three synthetic multielement standards (SMELS I, II and III) and two reference materials (RMs), SL-3 and Soil-7 of IAEA were analyzed for validation of the k0-based internal monostandard neutron activation analysis (IM-NAA) method utilizing in-situ relative detection efficiency. The internal monostandards used in SMELS and RMs were Au and Sc, respectively. The samples were irradiated in Apsara and Dhruva reactors, BARC and radioactive assay was carried out using a 40% relative efficiency HPGe detector coupled to an 8 k MCA. Concentrations of 23 elements were determined in both SMELS and RMs. In the case of RMs, concentrations of a few elements, whose certified values are not available, could also be determined. The % deviations for the elements determined in SMELS with respect to the assigned values and RMs with respect to certified values were within ±8%. The Z-score values at 95% confidence level for most of the elements in both the materials were within ±1.
THE GLOBAL ZERO MOVEMENT: A ROAD TO NOWHERE
2016-02-08
Agency ( IAEA ) to ensure continued compliance. Sixth recommendation: The United States must not adopt the concept of de- alerting its nuclear...nuclear weapons or moving fissile material in violation of NPT. These discussions should include intelligence community, law enforcement, and IAEA as
CREATION OF THE MODEL ADDITIONAL PROTOCOL
DOE Office of Scientific and Technical Information (OSTI.GOV)
Houck, F.; Rosenthal, M.; Wulf, N.
In 1991, the international nuclear nonproliferation community was dismayed to discover that the implementation of safeguards by the International Atomic Energy Agency (IAEA) under its NPT INFCIRC/153 safeguards agreement with Iraq had failed to detect Iraq's nuclear weapon program. It was now clear that ensuring that states were fulfilling their obligations under the NPT would require not just detecting diversion but also the ability to detect undeclared materials and activities. To achieve this, the IAEA initiated what would turn out to be a five-year effort to reappraise the NPT safeguards system. The effort engaged the IAEA and its Member Statesmore » and led to agreement in 1997 on a new safeguards agreement, the Model Protocol Additional to the Agreement(s) between States and the International Atomic Energy Agency for the Application of Safeguards. The Model Protocol makes explicit that one IAEA goal is to provide assurance of the absence of undeclared nuclear material and activities. The Model Protocol requires an expanded declaration that identifies a State's nuclear potential, empowers the IAEA to raise questions about the correctness and completeness of the State's declaration, and, if needed, allows IAEA access to locations. The information required and the locations available for access are much broader than those provided for under INFCIRC/153. The negotiation was completed in quite a short time because it started with a relatively complete draft of an agreement prepared by the IAEA Secretariat. This paper describes how the Model Protocol was constructed and reviews key decisions that were made both during the five-year period and in the actual negotiation.« less
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 2 2011-01-01 2011-01-01 false Expenses. 75.46 Section 75.46 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA AGREEMENT Advanced Notification and Expenses § 75.46 Expenses. (a) Under the Safeguards Agreement, the IAEA undertakes to...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 2 2010-01-01 2010-01-01 false Expenses. 75.46 Section 75.46 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA AGREEMENT Advanced Notification and Expenses § 75.46 Expenses. (a) Under the Safeguards Agreement, the IAEA undertakes to...
USSP-IAEA WORKSHOP ON ADVANCED SENSORS FOR SAFEGUARDS.
DOE Office of Scientific and Technical Information (OSTI.GOV)
PEPPER,S.; QUEIROLO, A.; ZENDEL, M.
2007-11-13
The IAEA Medium Term Strategy (2006-2011) defines a number of specific goals in respect to the IAEA's ability to provide assurances to the international community regarding the peaceful use of nuclear energy through States adherences to their respective non-proliferation treaty commitments. The IAEA has long used and still needs the best possible sensors to detect and measure nuclear material. The Department of Safeguards, recognizing the importance of safeguards-oriented R&D, especially targeting improved detection capabilities for undeclared facilities, materials and activities, initiated a number of activities in early 2005. The initiatives included letters to Member State Support Programs (MSSPs), personal contactsmore » with known technology holders, topical meetings, consultant reviews of safeguards technology, and special workshops to identify new and novel technologies and methodologies. In support of this objective, the United States Support Program to IAEA Safeguards hosted a workshop on ''Advanced Sensors for Safeguards'' in Santa Fe, New Mexico, from April 23-27, 2007. The Organizational Analysis Corporation, a U.S.-based management consulting firm, organized and facilitated the workshop. The workshop's goal was to help the IAEA identify and plan for new sensors for safeguards implementation. The workshop, which was attended by representatives of seven member states and international organizations, included presentations by technology holders and developers on new technologies thought to have relevance to international safeguards, but not yet in use by the IAEA. The presentations were followed by facilitated breakout sessions where the participants considered two scenarios typical of what IAEA inspectors might face in the field. One scenario focused on an enrichment plant; the other scenario focused on a research reactor. The participants brainstormed using the technologies presented by the participants and other technologies known to them to propose techniques and methods that could be used by the IAEA to strengthen safeguards. Creative thinking was encouraged during discussion of the proposals. On the final day of the workshop, the OAC facilitators summarized the participant's ideas in a combined briefing. This paper will report on the results of the April 2007 USSP-IAEA Workshop on Advanced Sensors for Safeguards and give an overview of the proposed technologies of greatest promise.« less
Sharpless, K E; Gill, L M
2000-01-01
A number of food-matrix reference materials (RMs) are available from the National Institute of Standards and Technology (NIST) and from Agriculture Canada through NIST. Most of these materials were originally value-assigned for their elemental composition (major, minor, and trace elements), but no additional nutritional information was provided. Two of the materials were certified for selected organic constituents. Ten of these materials (Standard Reference Material [SRM] 1,563 Cholesterol and Fat-Soluble Vitamins in Coconut Oil [Natural and Fortified], SRM 1,566b Oyster Tissue, SRM 1,570a Spinach Leaves, SRM 1,974a Organics in Mussel Tissue (Mytilus edulis), RM 8,415 Whole Egg Powder, RM 8,418 Wheat Gluten, RM 8,432 Corn Starch, RM 8,433 Corn Bran, RM 8,435 Whole Milk Powder, and RM 8,436 Durum Wheat Flour) were recently distributed by NIST to 4 laboratories with expertise in food analysis for the measurement of proximates (solids, fat, protein, etc.), calories, and total dietary fiber, as appropriate. SRM 1846 Infant Formula was distributed as a quality control sample for the proximates and for analysis for individual fatty acids. Two of the materials (Whole Egg Powder and Whole Milk Powder) were distributed in an earlier interlaboratory comparison exercise in which they were analyzed for several vitamins. Value assignment of analyte concentrations in these 11 SRMs and RMs, based on analyses by the collaborating laboratories, is described in this paper. These materials are intended primarily for validation of analytical methods for the measurement of nutrients in foods of similar composition (based on AOAC INTERNATIONAL's fat-protein-carbohydrate triangle). They may also be used as "primary control materials" in the value assignment of in-house control materials of similar composition. The addition of proximate information for 10 existing reference materials means that RMs are now available from NIST with assigned values for proximates in 6 of the 9 sectors of the AOAC triangle. Five of these materials have values assigned for total dietary fiber-the first such information provided for materials available from NIST.
Analysis of historical delta values for IAEA/LANL NDA training courses
DOE Office of Scientific and Technical Information (OSTI.GOV)
Geist, William; Santi, Peter; Swinhoe, Martyn
2009-01-01
The Los Alamos National Laboratory (LANL) supports the International Atomic Energy Agency (IAEA) by providing training for IAEA inspectors in neutron and gamma-ray Nondestructive Assay (NDA) of nuclear material. Since 1980, all new IAEA inspectors attend this two week course at LANL gaining hands-on experience in the application of NDA techniques, procedures and analysis to measure plutonium and uranium nuclear material standards with well known pedigrees. As part of the course the inspectors conduct an inventory verification exercise. This exercise provides inspectors the opportunity to test their abilities in performing verification measurements using the various NDA techniques. For an inspector,more » the verification of an item is nominally based on whether the measured assay value agrees with the declared value to within three times the historical delta value. The historical delta value represents the average difference between measured and declared values from previous measurements taken on similar material with the same measurement technology. If the measurement falls outside a limit of three times the historical delta value, the declaration is not verified. This paper uses measurement data from five years of IAEA courses to calculate a historical delta for five non-destructive assay methods: Gamma-ray Enrichment, Gamma-ray Plutonium Isotopics, Passive Neutron Coincidence Counting, Active Neutron Coincidence Counting and the Neutron Coincidence Collar. These historical deltas provide information as to the precision and accuracy of these measurement techniques under realistic conditions.« less
Wang, Bo-Shian; You, Chen-Feng; Huang, Kuo-Fang; Wu, Shein-Fu; Aggarwal, Suresh Kumar; Chung, Chuan-Hsiung; Lin, Pei-Ying
2010-09-15
An improved technique for precise and accurate determination of boron isotopic composition in Na-rich natural waters (groundwater, seawater) and marine biogenic carbonates was developed. This study used a 'micro-sublimation' technique to separate B from natural sample matrices in place of the conventional ion-exchange extraction. By adjusting analyte to appropriate pH, quantitative recovery of boron can be achieved (>98%) and the B procedural blank is limited to <8 pg. An additional mass bias effect in MC-ICP-MS was observed which could not be improved via the standard-sample-standard bracketing or the 'pseudo internal' normalization by Li. Therefore a standard other than NBS SRM 951 was used to monitor plasma condition in order to maintain analytical accuracy. An isotope cross-calibration with results from TIMS shows that the space-charge mass bias on MC-ICP-MS can be successfully corrected using off-line mathematical manipulation. Several reference materials, including the seawater IAPSO and two groundwater standards IAEA-B-2 and IAEA-B-3, were used to validate this approach. We found that the delta(11)B of the reference coral JCp-1 was 24.22+/-0.28 per thousand, corresponding to seawater pH based on the coral delta(11)B-pH function. Copyright (c) 2010 Elsevier B.V. All rights reserved.
Code of Federal Regulations, 2010 CFR
2010-01-01
... use. The IAEA is an international organization that establishes and administers safeguards designed to.... Euratom establishes and administers safeguards designed to ensure that special nuclear materials and other... or Euratom international safeguards use provided that IAEA or Euratom maintains control of or...
Bas Mor, H; Altinsoy, N; Söyler, I
2018-05-08
The aim of this study was to evaluate the radiation doses to patient during chest (posterior anterior/and lateral) examinations. The study was performed in three public hospitals of İstanbul province with a total of 300 adult patients. Entrance surface dose (ESD) measurements were conducted on computed radiography, digital radiography and screen film system. ESD was estimated by using International Atomic Energy Agency (IAEA) model and Davies model which are the common indirect models. Results were compared with diagnostic reference levels from the European Commission, IAEA and National Radiological Protection Board. Although the results are compatible with the international diagnostic reference levels, they present variations between the hospitals. Dose variations for the same type of X-ray examination support the idea that further optimization is possible.
Qi, Haiping; Coplen, Tyler B.; Geilmann, Heike; Brand, Willi A.; Böhlke, J.K.
2003-01-01
Analytical grade L-glutamic acid is chemically stable and has a C/N mole ratio of 5, which is close to that of many of natural biological materials, such as blood and animal tissue. Two L-glutamic acid reference materials with substantially different 13C and 15N abundances have been prepared for use as organic reference materials for C and N isotopic measurements. USGS40 is analytical grade L-glutamic acid and has a δ13C value of −26.24‰ relative to VPDB and a δ15N value of −4.52‰ relative to N2 in air. USGS41 was prepared by dissolving analytical grade L-glutamic acid with L-glutamic acid enriched in 13C and 15N. USGS41 has a δ13C value of +37.76‰ and a δ15N value of +47.57‰. The δ13C and δ15N values of both materials were measured against the international reference materials NBS 19 calcium carbonate (δ13C = +1.95‰), L-SVEC lithium carbonate (δ13C = −46.48‰), IAEA-N-1 ammonium sulfate (δ15N = 0.43‰), and USGS32 potassium nitrate (δ15N = 180‰) by on-line combustion continuous-flow and off-line dual-inlet isotope-ratio mass spectrometry. Both USGS40 and USGS41 are isotopically homogeneous; reproducibility of δ13C is better than 0.13‰, and that of δ15N is better than 0.13‰ in 100-μg amounts. These two isotopic reference materials can be used for (i) calibrating local laboratory reference materials, and (ii) quantifying drift with time, mass-dependent fractionations, and isotope-ratio-scale contraction in the isotopic analysis of various biological materials. Isotopic results presented in this paper yield a δ13C value for NBS 22 oil of −29.91‰, in contrast to the commonly accepted value of −29.78‰ for which off-line blank corrections probably have not been quantified satisfactorily.
New Organic Stable Isotope Reference Materials for Distribution through the USGS and the IAEA
NASA Astrophysics Data System (ADS)
Schimmelmann, Arndt; Qi, Haiping
2014-05-01
The widespread adoption of relative stable isotope-ratio measurements in organic matter by diverse scientific disciplines is at odds with the dearth of international organic stable isotopic reference materials (RMs). Only two of the few carbon (C) and nitrogen (N) organic RMs, namely L-glutamic acids USGS40 and USGS41 [1], both available from the U.S. Geological Survey (USGS) and the International Atomic Energy Agency (IAEA), provide an isotopically contrasting pair of organic RMs to enable essential 2-point calibrations for δ-scale normalization [2, 3]. The supply of hydrogen (H) organic RMs is even more limited. Numerous stable isotope laboratories have resorted to questionable practices, for example by using 'CO2, N2, and H2 reference gas pulses' for isotopic calibrations, which violates the principle of identical treatment of sample and standard (i.e., organic unknowns should be calibrated directly against chemically similar organic RMs) [4], or by using only 1 anchor instead of 2 for scale calibration. The absence of international organic RMs frequently serves as an excuse for indefensible calibrations. In 2011, the U.S. National Science Foundation (NSF) funded an initiative of 10 laboratories from 7 countries to jointly develop much needed new organic RMs for future distribution by the USGS and the IAEA. The selection of targeted RMs attempts to cover various common compound classes of broad technical and scientific interest. We had to accept compromises to approach the ideal of high chemical stability, lack of toxicity, and low price of raw materials. Hazardous gases and flammable liquids were avoided in order to facilitate international shipping of future RMs. With the exception of polyethylene and vacuum pump oil, all organic RMs are individual, chemically-pure substances, which can be used for compound-specific isotopic measurements in conjunction with liquid and gas chromatographic interfaces. The compounds listed below are under isotopic calibration by the 10 laboratories. Successfully calibrated organic RMs could become available as early as 2015. - n-Hexadecane (C16 n-alkane), three H, C-isotopic varieties; - Glycine (amino acid), three H, C, N-isotopic varieties; - L-valine (amino acid), three H, C, N-isotopic varieties; - Methyl n-heptadecanoate (methyl ester of C17 n-alkanoic fatty acid); - Methyl icosanoate (methyl ester of C20 n-alkanoic fatty acid), three H, C-isotopic varieties; - Caffeine, three H, C, N-isotopic varieties; - Hydrocarbon vacuum pump oils, two H-isotopic varieties; - Polyethylene powder, and possibly a 2H and 13C-enriched polyethylene string. [1] Qi H., Coplen T.B., Geilmann H., Brand W.A., Böhlke J.K. (2003) Two new organic reference materials for δ13C and δ15N measurements and a new value for the δ13C of NBS 22 oil. Rapid Communications in Mass Spectrometry 17, 2483-2487. [2] Coplen T.B. (1996) New guidelines for reporting stable hydrogen, carbon, and oxygen isotope-ratio data. Geochimica et Cosmochimica Acta 60, 3359-3360. [3] Coplen T.B., Brand W.A., Gehre M., Gröning M., Meijer H.A.J., Toman B., Verkouteren R.M. (2006) New guidelines for δ13C measurements. Analytical Chemistry 78 (7), 2439-2441. [4] Werner R.A., Brand W.A. (2001) Referencing strategies and techniques in stable isotope ratio analysis. Rapid Communications in Mass Spectrometry 15, 501-519.
NASA Astrophysics Data System (ADS)
Vittone, Ettore; Breese, Mark; Simon, Aliz
2016-04-01
Within the International Atomic Energy Agency (IAEA) Department of Nuclear Sciences and Applications, activities are carried out to assist and advise IAEA Member States in assessing their needs for capacity building, research and development in nuclear sciences. Support is also provided to Member States' activities geared towards deriving benefits in fields such as (i) advanced materials for nuclear applications, (ii) application of accelerators and associated instrumentation, and (iii) nuclear, atomic and molecular data. One of the means that the IAEA uses to deliver its programme is Coordinated Research Projects (CRPs) which are very effective in stimulating international research and scientific interaction among the Member States.
PREFACE: Light element atom, molecule and radical behaviour in the divertor and edge plasma regions
NASA Astrophysics Data System (ADS)
Braams, Bastiaan J.; Chung, Hyun-Kung
2015-01-01
This volume of Journal of Physics: Conference Series contains contributions by participants in an International Atomic Energy Agency (IAEA) Coordinated Research Project (CRP) on "Light element atom, molecule and radical behaviour in the divertor and edge plasma regions" (in magnetic fusion devices). Light elements are the dominant impurity species in fusion experiments and in the near-wall plasma they occur as atoms or ions and also as hydrides and other molecules and molecular ions. Hydrogen (H or D, and T in a reactor) is the dominant species in fusion experiments, but all light elements He - O and Ne are of interest for various reasons. Helium is a product of the D+T fusion reaction and is introduced in experiments for transport studies. Lithium is used for wall coating and also as a beam diagnostic material. Beryllium is foreseen as a wall material for the ITER experiment and is used on the Joint European Torus (JET) experiment. Boron may be used as a coating material for the vessel walls. Carbon (graphite or carbon-fiber composite) is often used as the target material for wall regions subject to high heat load. Nitrogen may be used as a buffer gas for edge plasma cooling. Oxygen is a common impurity in experiments due to residual water vapor. Finally, neon is another choice as a buffer gas. Data for collisional and radiative processes involving these species are important for plasma modelling and for diagnostics. The participants in the CRP met 3 times over the years 2009-2013 for a research coordination meeting. Reports and presentation materials for these meetings are available through the web page on coordinated research projects of the (IAEA) Atomic and Molecular Data Unit [1]. Some of the numerical data generated in the course of the CRP is available through the ALADDIN database [2]. The IAEA takes the opportunity to thank the participants in the CRP for their dedicated efforts in the course of the CRP and for their contributions to this volume. The IAEA scientific officers for this project were Mr Bastiaan J. Braams and Ms Hyun-Kyung Chung. [1] See: https://www-amdis.iaea.org/CRP/ [2] See: https://www-amdis.iaea.org/ALADDIN/
New Brunswick Laboratory. Progress report, October 1995--September 1996
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
Fiscal year (FY) 1996 was a very good year for New Brunswick Laboratory (NBL), whose major sponsor is the Office of Safeguards and Security (NN-51) in the US Department of Energy (DOE), Office of Nonproliferation and National Security, Office of Security Affairs. Several projects pertinent to the NBL mission were completed, and NBL`s interactions with partners and customers were encouraging. Among the partners with which NBL interacted in this report period were the International Atomic Energy Agency (IAEA), NN-51. Environmental Program Group of the DOE Chicago Operations Office, International Safeguards Project Office, Waste Isolation Pilot Plant (WIPP), Ukraine Working Group,more » Fissile Materials Assurance Working Group, National Institute of Standards and Technology (NIST), Nuclear Regulatory Commission (NRC), Institute for Reference Materials and Measurements (IRMM) in Belgium, Brazilian/Argentine Agency for Accounting and Control of Nuclear Materials (ABACC), Lockheed Idaho Technologies Company, and other DOE facilities and laboratories. NBL staff publications, participation in safeguards assistance and other nuclear programs, development of new reference materials, involvement in the updating and refinement of DOE documents, service in enhancing the science education of others, and other related activities enhanced NBL`s status among DOE laboratories and facilities. Noteworthy are the facts that NBL`s small inventory of nuclear materials is accurately accounted for, and, as in past years, its materials and human resources were used in peaceful nuclear activities worldwide.« less
NASA Astrophysics Data System (ADS)
Moro, M. V.; Bruckner, B.; Grande, P. L.; Tabacniks, M. H.; Bauer, P.; Primetzhofer, D.
2018-06-01
We have experimentally determined electronic stopping cross sections of vanadium for 50-2750 keV protons and for 250-6000 keV He ions by relative measurements in backscattering geometry. To check the consistency of the employed procedure we investigate how to define adequate reference stopping cross section data and chose different reference materials. To proof consistency of different reference data sets, an intercomparison is performed to test the reliability of the evaluation procedure for a wide range of energies. This process yielded consistent results. The resulting stopping cross section data for V are compared to values from the IAEA database, to the most commonly employed semi-empirical program SRIM, and to calculations according to CasP. For helium, our results show a significant deviation of up to 10% with respect to literature and to SRIM, but are in very good agreement with the CasP predictions, in particular when charge-exchange processes are included in the model.
Jangda, Abdul Qadir; Hussein, Sherali
2012-05-01
In external beam radiation therapy (EBRT), the quality assurance (QA) of the radiation beam is crucial to the accurate delivery of the prescribed dose to the patient. One of the dosimetric parameters that require monitoring is the beam output, specified as the dose rate on the central axis under reference conditions. The aim of this project was to validate dose rate calibration of megavoltage photon beams using the International Atomic Energy Agency (IAEA)/World Health Organisation (WHO) postal audit dosimetry service. Three photon beams were audited: a 6 MV beam from the low-energy linac and 6 and 18 MV beams from a dual high-energy linac. The agreement between our stated doses and the IAEA results was within 1% for the two 6 MV beams and within 2% for the 18 MV beam. The IAEA/WHO postal audit dosimetry service provides an independent verification of dose rate calibration protocol by an international facility.
Materials Data on Na7AlSn11(PO4)18 (SG:1) by Materials Project
Kristin Persson
2014-07-09
Computed materials data using density functional theory calculations. These calculations determine the electronic structure of bulk materials by solving approximations to the Schrodinger equation. For more information, see https://materialsproject.org/docs/calculations
Ceballos, Melisa Rodas; García-Tenorio, Rafael; Estela, José Manuel; Cerdà, Víctor; Ferrer, Laura
2017-12-01
Leached fractions of U and Th from different environmental solid matrices were evaluated by an automatic system enabling the on-line lixiviation and extraction/pre-concentration of these two elements previous ICP-MS detection. UTEVA resin was used as selective extraction material. Ten leached fraction, using artificial rainwater (pH 5.4) as leaching agent, and a residual fraction were analyzed for each sample, allowing the study of behavior of U and Th in dynamic lixiviation conditions. Multivariate techniques have been employed for the efficient optimization of the independent variables that affect the lixiviation process. The system reached LODs of 0.1 and 0.7ngkg -1 of U and Th, respectively. The method was satisfactorily validated for three solid matrices, by the analysis of a soil reference material (IAEA-375), a certified sediment reference material (BCR- 320R) and a phosphogypsum reference material (MatControl CSN-CIEMAT 2008). Besides, environmental samples were analyzed, showing a similar behavior, i.e. the content of radionuclides decreases with the successive extractions. In all cases, the accumulative leached fraction of U and Th for different solid matrices studied (soil, sediment and phosphogypsum) were extremely low, up to 0.05% and 0.005% of U and Th, respectively. However, a great variability was observed in terms of mass concentration released, e.g. between 44 and 13,967ngUkg -1 . Copyright © 2017 Elsevier B.V. All rights reserved.
Stable isotope quality assurance using the 'calibrated IRMS' strategy.
Meijer, Harro A J
2009-06-01
Procedures in our laboratory have always been directed towards complete understanding of all processes involved and corrections needed etc., instead of relying fully on laboratory reference materials. This rather principal strategy (or attitude) is probably not optimal in the economic sense, and is not necessarily more accurate either. Still, it has proven to be very rewarding in its capability to detect caveats that go undiscovered in the standard way of measurement, but that do influence the accuracy or reliability of the measurement procedure. An additional benefit of our laboratory procedures is that it makes us capable of assisting the International Atomic Energy Agency (IAEA) with primary questions like mutual scale assignments and comparison of isotope ratios of the same isotope in different matrices (like delta(18)O in water, carbonates and atmospheric CO(2)), establishment of the (17)O-(18)O relation, and the replenishment of the calibration standards. Finally, for manual preparation systems with a low sample throughput (and thus only few reference materials analysed) it may well be the only way to produce reliable results.
Taylor, Vivien F; Toms, Andrew; Longerich, Henry P
2002-01-01
The application of open vessel focused microwave acid digestion is described for the preparation of geological and environmental samples for analysis using inductively coupled plasma-mass spectrometry (ICP-MS). The method is compared to conventional closed-vessel high pressure methods which are limited in the use of HF to break down silicates. Open-vessel acid digestion more conveniently enables the use of HF to remove Si from geological and plant samples as volatile SiF4, as well as evaporation-to-dryness and sequential acid addition during the procedure. Rock reference materials (G-2 granite, MRG-1 gabbros, SY-2 syenite, JA-1 andesite, and JB-2 and SRM-688 basalts) and plant reference materials (BCR and IAEA lichens, peach leaves, apple leaves, Durham wheat flour, and pine needles) were digested with results comparable to conventional hotplate digestion. The microwave digestion method gave poor results for granitic samples containing refractory minerals, however fusion was the preferred method of preparation for these samples. Sample preparation time was reduced from several days, using conventional hotplate digestion method, to one hour per sample using our microwave method.
Fault displacement hazard assessment for nuclear installations based on IAEA safety standards
NASA Astrophysics Data System (ADS)
Fukushima, Y.
2016-12-01
In the IAEA Safety NS-R-3, surface fault displacement hazard assessment (FDHA) is required for the siting of nuclear installations. If any capable faults exist in the candidate site, IAEA recommends the consideration of alternative sites. However, due to the progress in palaeoseismological investigations, capable faults may be found in existing site. In such a case, IAEA recommends to evaluate the safety using probabilistic FDHA (PFDHA), which is an empirical approach based on still quite limited database. Therefore a basic and crucial improvement is to increase the database. In 2015, IAEA produced a TecDoc-1767 on Palaeoseismology as a reference for the identification of capable faults. Another IAEA Safety Report 85 on ground motion simulation based on fault rupture modelling provides an annex introducing recent PFDHAs and fault displacement simulation methodologies. The IAEA expanded the project of FDHA for the probabilistic approach and the physics based fault rupture modelling. The first approach needs a refinement of the empirical methods by building a world wide database, and the second approach needs to shift from kinematic to the dynamic scheme. Both approaches can complement each other, since simulated displacement can fill the gap of a sparse database and geological observations can be useful to calibrate the simulations. The IAEA already supported a workshop in October 2015 to discuss the existing databases with the aim of creating a common worldwide database. A consensus of a unified database was reached. The next milestone is to fill the database with as many fault rupture data sets as possible. Another IAEA work group had a WS in November 2015 to discuss the state-of-the-art PFDHA as well as simulation methodologies. Two groups jointed a consultancy meeting in February 2016, shared information, identified issues, discussed goals and outputs, and scheduled future meetings. Now we may aim at coordinating activities for the whole FDHA tasks jointly.
International Scavenging for First Responder Guidance and Tools: IAEA Products
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stern, W.; Berthelot, L.; Bachner, K.
In fiscal years (FY) 2016 and 2017, with support from the U.S. Department of Homeland Security (DHS), Brookhaven National Laboratory (BNL) examined the International Atomic Energy Agency (IAEA) radiological emergency response and preparedness products (guidance and tools) to determine which of these products could be useful to U.S. first responders. The IAEA Incident and Emergency Centre (IEC), which is responsible for emergency preparedness and response, offers a range of tools and guidance documents for responders in recognizing, responding to, and recovering from radiation emergencies and incidents. In order to implement this project, BNL obtained all potentially relevant tools and productsmore » produced by the IAEA IEC and analyzed these materials to determine their relevance to first responders in the U.S. Subsequently, BNL organized and hosted a workshop at DHS National Urban Security Technology Laboratory (NUSTL) for U.S. first responders to examine and evaluate IAEA products to consider their applicability to the United States. This report documents and describes the First Responder Product Evaluation Workshop, and provides recommendations on potential steps the U.S. federal government could take to make IAEA guidance and tools useful to U.S. responders.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, Leon E.; Conrad, Ryan C.; Keller, Daniel T.
The International Atomic Energy Agency (IAEA) deploys unattended monitoring systems to provide continuous monitoring of nuclear material within safeguarded facilities around the world. As the number of unattended monitoring instruments increases, the IAEA is challenged to become more efficient in the implementation of those systems. In 2010, the IAEA initiated the Front-End Electronics for Unattended Measurement (FEUM) project with the goals of greater flexibility in the interfaces to various sensors and data acquisition systems, and improved capabilities for remotely located sensors (e.g., where sensor and front-end electronics might be separated by tens of meters). In consultation with the IAEA, amore » technical evaluation of a candidate FEUM device produced by a commercial vendor is being performed. This evaluation is assessing the device against the IAEA’s original technical specifications and a broad range of important parameters that included sensor types, cable types, and industrial electromagnetic noise that can degrade signals from remotely located detectors. Testing has been performed in a laboratory and also in environments representative of IAEA deployments. The results are expected to inform the IAEA about where and how FEUM devices might be implemented in the field. Data and preliminary findings from the testing performed to date are presented.« less
Beam quality corrections for parallel-plate ion chambers in electron reference dosimetry
NASA Astrophysics Data System (ADS)
Zink, K.; Wulff, J.
2012-04-01
Current dosimetry protocols (AAPM, IAEA, IPEM, DIN) recommend parallel-plate ionization chambers for dose measurements in clinical electron beams. This study presents detailed Monte Carlo simulations of beam quality correction factors for four different types of parallel-plate chambers: NACP-02, Markus, Advanced Markus and Roos. These chambers differ in constructive details which should have notable impact on the resulting perturbation corrections, hence on the beam quality corrections. The results reveal deviations to the recommended beam quality corrections given in the IAEA TRS-398 protocol in the range of 0%-2% depending on energy and chamber type. For well-guarded chambers, these deviations could be traced back to a non-unity and energy-dependent wall perturbation correction. In the case of the guardless Markus chamber, a nearly energy-independent beam quality correction is resulting as the effects of wall and cavity perturbation compensate each other. For this chamber, the deviations to the recommended values are the largest and may exceed 2%. From calculations of type-B uncertainties including effects due to uncertainties of the underlying cross-sectional data as well as uncertainties due to the chamber material composition and chamber geometry, the overall uncertainty of calculated beam quality correction factors was estimated to be <0.7%. Due to different chamber positioning recommendations given in the national and international dosimetry protocols, an additional uncertainty in the range of 0.2%-0.6% is present. According to the IAEA TRS-398 protocol, the uncertainty in clinical electron dosimetry using parallel-plate ion chambers is 1.7%. This study may help to reduce this uncertainty significantly.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carla Miller; Mary Adamic; Stacey Barker
Traditionally, IAEA inspectors have focused on the detection of nuclear indicators as part of infield inspection activities. The ability to rapidly detect and identify chemical as well as nuclear signatures can increase the ability of IAEA inspectors to detect undeclared activities at a site. Identification of chemical indicators have been limited to use in the analysis of environmental samples. Although IAEA analytical laboratories are highly effective, environmental sample processing does not allow for immediate or real-time results to an IAEA inspector at a facility. During a complementary access inspection, under the Additional Protocol, the use of fieldable technologies that canmore » quickly provide accurate information on chemicals that may be indicative of undeclared activities can increase the ability of IAEA to effectively and efficiently complete their mission. The Complementary Access Working Group (CAWG) is a multi-laboratory team with members from Brookhaven National Laboratory, Idaho National Laboratory, Los Alamos National Laboratory, and Sandia National Laboratory. The team identified chemicals at each stage of the nuclear fuel cycle that may provide IAEA inspectors with indications that proliferation activities may be occurring. The group eliminated all indicators related to equipment, technology and training, developing a list of by-products/effluents, non-nuclear materials, nuclear materials, and other observables. These proliferation indicators were prioritized based on detectability from a conduct of operations (CONOPS) perspective of a CA inspection (for example, whether an inspector actually can access the S&O or whether it is in process with no physical access), and the IAEA’s interest in the detection technology in conjunction with radiation detectors. The list was consolidated to general categories (nuclear materials from a chemical detection technique, inorganic chemicals, organic chemicals, halogens, and miscellaneous materials). The team then identified commercial off the shelf (COTS) chemical detectors that may detect the chemicals of interest. Three chemical detectors were selected and tested both in laboratory settings and in field operations settings at Idaho National Laboratory. The instruments selected are: Thermo Scientific TruDefender FT (FTIR), Thermo Scientific FirstDefender RM (Raman), and Bruker Tracer III SD (XRF). Functional specifications, operability, and chemical detectability, selectivity, and limits of detection were determined. Results from the laboratory and field tests will be presented. This work is supported by the Next Generation Safeguards Initiative, Office of Nonproliferation and International Security, National Nuclear Security Administration.« less
NASA Astrophysics Data System (ADS)
Visetpotjanakit, S.; Kaewpaluek, S.
2017-06-01
A proficiency test (PT) exercise has proposed by the International Atomic Energy Agency (IAEA) in the frame of the IAEA Technical Cooperation project RAS/7/021 “Marine benchmark study on the possible impact of the Fukushima radioactive releases in the Asia-Pacific Region for Caesium Determination in Sea Water” since 2012. In 2015 the exercise was referred to Proficiency Test for Tritium, Strontium and Caesium Isotopes in Seawater 2015 (IAEA-RML-2015-02) to analyse3H, 134Cs, 137Cs and90Sr in a seawater sample. OAP was one of the 17 laboratories from 15 countries from Asia-Pacific Region who joined the PT exercise. The aim of our participation was to validate our analytical performance for the accurate determination of radionuclides in seawater by developed methods of radiochemical analysis. OAP submitted results determining the concentration for the three elements i.e. 134Cs, 137Cs and90Sr in seawater to the IAEA. A critical review was made to check suitability of our methodology and the criteria for the accuracy, precision and trueness of our data. The results of both 134Cs and 137Cs passed all criteria which were assigned “Accepted” statuses. Whereas 90Sr analysis did not pass the accuracy test therefore it was considered as “Not accepted” Our results and all other participant results with critical comments were published in the IAEA proficiency test report.
NASA Astrophysics Data System (ADS)
Mandic, M.; Stöbener, N.; Smajgl, D.
2017-12-01
For many decades different instrumental methods involving generations of the isotope ratio mass spectrometers with different periphery units for sample preparation, have provided scientifically required high precision, and high throughput of samples for varies application - from geological and hydrological to food and forensic. With this work we introduce automated measurement of δ13C and δ18O from solid carbonate samples, DIC and δ18O of water. We have demonstrated usage of a Thermo Scientific™ Delta Ray™ IRIS with URI Connect on certified reference materials and confirmed the high achievable accuracy and a precision better then <0.1‰ for both δ13C and δ18O, in the laboratory or the field with same precision and throughput of samples. With equilibration method for determination of δ18O in water samples, which we present in this work, achieved repeatability and accuracy are 0.12‰ and 0.68‰ respectively, which fulfill requirements of regulatory methods. The preparation of the samples for carbonate and DIC analysis on the Delta Ray IRIS with URI Connect is similar to the previously mentioned Gas Bench II methods. Samples are put into vials and phosphoric acid is added. The resulting sample-acid chemical reaction releases CO2 gas, which is then introduced into the Delta Ray IRIS via the Variable Volume. Three international standards of carbonate materials (NBS-18, NBS-19 and IAEA-CO-1) were analyzed. NBS-18 and NBS-19 were used as standards for calibration, and IAEA-CO-1 was treated as unknown. For water sample analysis equilibration method with 1% of CO2 in dry air was used. Test measurements and conformation of precision and accuracy of method determination δ18O in water samples were done with three lab standards, namely ANST, OCEAN 2 and HBW. All laboratory standards were previously calibrated with international reference material VSMOW2 and SLAP2 to assure accuracy of the isotopic values. The Principle of Identical Treatment was applied in sample and standard preparation, in measurement procedure, as well as in the evaluation of the results.
Best Practices for NPT Transit Matching
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gilligan, Kimberly V.; Whitaker, J. Michael; Oakberg, John A.
2016-09-01
Transit matching is the process for relating or matching reports of shipments and receipts submitted to the International Atomic Energy Agency (IAEA). Transit matching is a component used by the IAEA in drawing safeguards conclusions and performing investigative analysis. Transit matching is part of IAEA safeguards activities and the State evaluation process, and it is included in the annual Safeguards Implementation Report (SIR). Annually, the IAEA currently receives reports of ~900,000 nuclear material transactions, of which ~500,000 are for domestic and foreign transfers. Of these the IAEA software can automatically match (i.e., machine match) about 95% of the domestic transfersmore » and 25% of the foreign transfers. Given the increasing demands upon IAEA resources, it is highly desirable for the machine-matching process to match as many transfers as possible. Researchers at Oak Ridge National Laboratory (ORNL) have conducted an investigation funded by the National Nuclear Security Administration through the Next Generation Safeguards Initiative to identify opportunities to strengthen IAEA transit matching. Successful matching, and more specifically machine matching, is contingent on quality data from the reporting States. In February 2016, ORNL hosted representatives from three States, the IAEA, and Euratom to share results from past studies and to discuss the processes, policies, and procedures associated with State reporting for transit matching. Drawing on each entity's experience and knowledge, ORNL developed a best practices document to be shared with the international safeguards community to strengthen transit matching. This paper shares the recommendations that resulted from this strategic meeting and the next steps being taken to strengthen transit matching.« less
Romanian Experience for Enhancing Safety and Security in Transport of Radioactive Material - 12223
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vieru, Gheorghe
2012-07-01
The transport of Dangerous Goods-Class no.7 Radioactive Material (RAM), is an important part of the Romanian Radioactive Material Management. The overall aim of this activity is for enhancing operational safety and security measures during the transport of the radioactive materials, in order to ensure the protection of the people and the environment. The paper will present an overall of the safety and security measures recommended and implemented during transportation of RAM in Romania. Some aspects on the potential threat environment will be also approached with special referring to the low level radioactive material (waste) and NORM transportation either by roadmore » or by rail. A special attention is given to the assessment and evaluation of the possible radiological consequences due to RAM transportation. The paper is a part of the IAEA's Vienna Scientific Research Contract on the State Management of Nuclear Security Regime (Framework) concluded with the Institute for Nuclear Research, Romania, where the author is the CSI (Chief Scientific Investigator). The transport of RAM in Romania is a very sensible and complex problem taking into consideration the importance and the need of the security and safety for such activities. The Romanian Nuclear Regulatory Body set up strictly regulation and procedures according to the Recommendation of the IAEA Vienna and other international organizations. There were implemented the adequate regulation and procedures in order to keep the environmental impacts and the radiological consequences at the lower possible level and to assure the effectiveness of state nuclear security regime due to possible malicious acts in carrying out these activities including transport and the disposal site at the acceptable international levels. The levels of the estimated doses and risk expectation values for transport and disposal are within the acceptable limits provided by national and international regulations and recommendations but can increase, significantly during potential malicious acts. (authors)« less
web-based interactive data processing: application to stable isotope metrology.
Verkouteren, R M; Lee, J N
2001-08-01
To address a fundamental need in stable isotope metrology, the National Institute of Standards and Technology (NIST) has established a web-based interactive data-processing system accessible through a common gateway interface (CGI) program on the internet site http://www. nist.gov/widps-co2. This is the first application of a web-based tool that improves the measurement traceability afforded by a series of NIST standard materials. Specifically, this tool promotes the proper usage of isotope reference materials (RMs) and improves the quality of reported data from extensive measurement networks. Through the International Atomic Energy Agency (IAEA), we have defined standard procedures for stable isotope measurement and data-processing, and have determined and applied consistent reference values for selected NIST and IAEA isotope RMs. Measurement data of samples and RMs are entered into specified fields on the web-based form. These data are submitted through the CGI program on a NIST Web server, where appropriate calculations are performed and results returned to the client. Several international laboratories have independently verified the accuracy of the procedures and algorithm for measurements of naturally occurring carbon-13 and oxygen-18 abundances and slightly enriched compositions up to approximately 150% relative to natural abundances. To conserve the use of the NIST RMs, users may determine value assignments for a secondary standard to be used in routine analysis. Users may also wish to validate proprietary algorithms embedded in their laboratory instrumentation, or specify the values of fundamental variables that are usually fixed in reduction algorithms to see the effect on the calculations. The results returned from the web-based tool are limited in quality only by the measurements themselves, and further value may be realized through the normalization function. When combined with stringent measurement protocols, two- to threefold improvements have been realized in the reproducibility of carbon-13 and oxygen-18 determinations across laboratories.
King, Trude V.V.; Hoefen, Todd M.; Kokaly, Raymond F.; Livo, Keith E.; Johnson, Michaela R.; Giles, Stuart A.
2013-01-01
This map shows the spatial distribution of selected iron-bearing minerals and other materials derived from analysis of airborne HyMap™ imaging spectrometer (hyperspectral) data of Afghanistan collected in late 2007. This map is one in a series of U.S. Geological Survey/Afghanistan Geological Survey quadrangle maps covering Afghanistan. Flown at an altitude of 50,000 feet (15,240 meters (m)), the HyMap™ imaging spectrometer measured reflected sunlight in 128 channels, covering wavelengths between 0.4 and 2.5 μm. The data were georeferenced, atmospherically corrected and converted to apparent surface reflectance, empirically adjusted using ground-based reflectance measurements, and combined into a mosaic with 23-m pixel spacing. Variations in water vapor and dust content of the atmosphere, in solar angle, and in surface elevation complicated correction; therefore, some classification differences may be present between adjacent flight lines. The reflectance spectrum of each pixel of HyMap™ imaging spectrometer data was compared to the reference materials in a spectral library of minerals, vegetation, water, and other materials. Minerals occurring abundantly at the surface and those having unique spectral features were easily detected and discriminated, while minerals having slightly different compositions but similar spectral features were less easily discriminated; thus, some map classes consist of several minerals having similar spectra, such as “Goethite and jarosite.” A designation of “Not classified” was assigned to the pixel when there was no match with reference spectra.
10 CFR 75.35 - Material status reports.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 2 2011-01-01 2011-01-01 false Material status reports. 75.35 Section 75.35 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA AGREEMENT Reports § 75.35 Material status reports. (a) A material status report must be submitted for each...
Karydas, Andreas Germanos; Czyzycki, Mateusz; Leani, Juan José; Migliori, Alessandro; Osan, Janos; Bogovac, Mladen; Wrobel, Pawel; Vakula, Nikita; Padilla-Alvarez, Roman; Menk, Ralf Hendrik; Gol, Maryam Ghahremani; Antonelli, Matias; Tiwari, Manoj K; Caliri, Claudia; Vogel-Mikuš, Katarina; Darby, Iain; Kaiser, Ralf Bernd
2018-01-01
The International Atomic Energy Agency (IAEA) jointly with the Elettra Sincrotrone Trieste (EST) operates a multipurpose X-ray spectrometry endstation at the X-ray Fluorescence beamline (10.1L). The facility has been available to external users since the beginning of 2015 through the peer-review process of EST. Using this collaboration framework, the IAEA supports and promotes synchrotron-radiation-based research and training activities for various research groups from the IAEA Member States, especially those who have limited previous experience and resources to access a synchrotron radiation facility. This paper aims to provide a broad overview about various analytical capabilities, intrinsic features and performance figures of the IAEA X-ray spectrometry endstation through the measured results. The IAEA-EST endstation works with monochromatic X-rays in the energy range 3.7-14 keV for the Elettra storage ring operating at 2.0 or 2.4 GeV electron energy. It offers a combination of different advanced analytical probes, e.g. X-ray reflectivity, X-ray absorption fine-structure measurements, grazing-incidence X-ray fluorescence measurements, using different excitation and detection geometries, and thereby supports a comprehensive characterization for different kinds of nanostructured and bulk materials.
IAEA activities on atomic, molecular and plasma-material interaction data for fusion
NASA Astrophysics Data System (ADS)
Braams, Bastiaan J.; Chung, Hyun-Kyung
2013-09-01
The IAEA Atomic and Molecular Data Unit (http://www-amdis.iaea.org/) aims to provide internationally evaluated and recommended data for atomic, molecular and plasma-material interaction (A+M+PMI) processes in fusion research. The Unit organizes technical meetings and coordinates an A+M Data Centre Network (DCN) and a Code Centre Network (CCN). In addition the Unit organizes Coordinated Research Projects (CRPs), for which the objectives are mixed between development of new data and evaluation and recommendation of existing data. In the area of A+M data we are placing new emphasis in our meeting schedule on data evaluation and especially on uncertainties in calculated cross section data and the propagation of uncertainties through structure data and fundamental cross sections to effective rate coefficients. Following a recent meeting of the CCN it is intended to use electron scattering on Be, Ne and N2 as exemplars for study of uncertainties and uncertainty propagation in calculated data; this will be discussed further at the presentation. Please see http://www-amdis.iaea.org/CRP/ for more on our active and planned CRPs, which are concerned with atomic processes in core and edge plasma and with plasma interaction with beryllium-based surfaces and with irradiated tungsten.
10 CFR 75.8 - IAEA inspections.
Code of Federal Regulations, 2011 CFR
2011-01-01
... exports) or § 75.43(c) (pertaining to imports) at any place where nuclear material may be located; (3... nuclear material at key measurement points for material balance accounting are representative; (3) Verify... samples at key measurement points for material balance accounting are taken in accordance with procedures...
Lessons Learned From Developing Reactor Pressure Vessel Steel Embrittlement Database
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Jy-An John
Materials behaviors caused by neutron irradiation under fission and/or fusion environments can be little understood without practical examination. Easily accessible material information system with large material database using effective computers is necessary for design of nuclear materials and analyses or simulations of the phenomena. The developed Embrittlement Data Base (EDB) at ORNL is this comprehensive collection of data. EDB database contains power reactor pressure vessel surveillance data, the material test reactor data, foreign reactor data (through bilateral agreements authorized by NRC), and the fracture toughness data. The lessons learned from building EDB program and the associated database management activity regardingmore » Material Database Design Methodology, Architecture and the Embedded QA Protocol are described in this report. The development of IAEA International Database on Reactor Pressure Vessel Materials (IDRPVM) and the comparison of EDB database and IAEA IDRPVM database are provided in the report. The recommended database QA protocol and database infrastructure are also stated in the report.« less
Database of natural matrix reference materials (NMRM) for organic constituents.
Iyengar, G V; Bleise, A R
2001-06-01
The International Atomic Energy Agency maintains a database of internationally available certified reference materials (CRM) of natural matrices. This database is periodically updated, and presently documents nearly 25,000 measurands in 1,700 materials. The organic constituents are classified in five major groups of analytes aliphatic and aromatic hydrocarbons (A), chlorinated hydrocarbons (B), pesticides (C), organometallic compounds (D) and other organic constituents (nutrients, etc.) (E). The matrices include natural materials such as body fluids, food products, soils, and sediments, terrestrial (e.g. plants), and anthropogenic products (e.g. dust, fly ash). These five organic groups of analytes encompass more than 2000 measurands for 420 different analytes in 230 materials. Of these measurands, 1,682 (68%) are certified, and 768 (32%) are provided as informational values. Within each major group of analytes, measurands reported as informational values accounted for: A (35%); B (35%); C (26%); D (10%), and E (22%). The high proportion of informational values (i.e. non-certified values) for A, B, and C, compares well with a similar but undesirable situation faced in the nineteen-seventies in the inorganic area when simultaneous multielement techniques became available. In the case of D and E, it appears that mostly targeted analytes are measured, leading to a cohesive certification profile. Although the IAEA database is not equally comprehensive for all groups of analytes cited above, it can still serve as an useful indicator of the status of organic constituents in RMs.
Special nuclear materials cutoff exercise: Issues and lessons learned. Volume 3
DOE Office of Scientific and Technical Information (OSTI.GOV)
Libby, R.A.; Segal, J.E.; Stanbro, W.D.
1995-08-01
This document is appendices D-J for the Special Nuclear Materials Cutoff Exercise: Issues and Lessons Learned. Included are discussions of the US IAEA Treaty, safeguard regulations for nuclear materials, issue sheets for the PUREX process, and the LANL follow up activity for reprocessing nuclear materials.
Tulasi, Delali; Adotey, Dennis; Affum, Andrews; Carboo, Derick; Serfor-Armah, Yaw
2013-10-01
Total As content and the As species distribution in water and sediments from the Kwabrafo stream, a major water body draining the Obuasi gold mining community in southwestern Ghana, have been investigated. Total As content was determined by instrumental neutron activation analysis (INAA). Ion-pair reverse phase high-performance liquid chromatography-neutron activation analysis (HPLC-NAA) was used for speciation of As species. Solid phase extraction with phosphate buffer was used to extract soluble As species from lyophilized sediment. The mass balance after phosphate extraction of soluble As species in sediment varied from 89 to 96 %. Compositionally appropriate reference material International Atomic Energy Agency (IAEA)-Lake Sediment (SL)-1 was used to check the validity of INAA method for total As determination. The measured values are in good agreement with the IAEA recommended value and also within the 95 % confidence interval. The accuracy of the measurement in terms of relative deviation from the IAEA recommended value was ±0.83 %. "In-house" prepared As(III) and As(V) standards were used to validate the HPLC-INAA method used for the As species determination. Total As concentration in the water samples ranged from 1.15 to 9.20 mg/L. As(III) species in water varied from 0.13 to 0.7 mg/L, while As(V) species varied from 0.79 to 3.85 mg/L. Total As content in sediment ranged from 2,134 to 3,596 mg/kg dry mass. The levels of As(III) and As(V) species in the sediment ranges from 138 to 506 mg/kg dry mass and 156 to 385 mg/kg dry mass, respectively.
Reference dosimeter system of the iaea
NASA Astrophysics Data System (ADS)
Mehta, Kishor; Girzikowsky, Reinhard
1995-09-01
Quality assurance programmes must be in operation at radiation processing facilities to satisfy national and international Standards. Since dosimetry has a vital function in these QA programmes, it is imperative that the dosimetry systems in use at these facilities are well calibrated with a traceability to a Primary Standard Dosimetry Laboratory. As a service to the Member States, the International Atomic Energy Agency operates the International Dose Assurance Service (IDAS) to assist in this process. The transfer standard dosimetry system that is used for this service is based on ESR spectrometry. The paper describes the activities undertaken at the IAEA Dosimetry Laboratory to establish the QA programme for its reference dosimetry system. There are four key elements of such a programme: quality assurance manual; calibration that is traceable to a Primary Standard Dosimetry Laboratory; a clear and detailed statement of uncertainty in the dose measurement; and, periodic quality audit.
Non-Proliferation, the IAEA Safeguards System, and the importance of nuclear material measurements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stevens, Rebecca S.
2017-09-18
The objective of this project is to explain the contribution of nuclear material measurements to the system of international verification of State declarations and the non-proliferation of nuclear weapons.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Komann, Steffen; Groeke, Carsten; Droste, Bernhard
The majority of transports of radioactive materials are carried out in packages which don't need a package design approval by a competent authority. Low-active radioactive materials are transported in such packages e.g. in the medical and pharmaceutical industry and in the nuclear industry as well. Decommissioning of NPP's leads to a strong demand for packages to transport low and middle active radioactive waste. According to IAEA regulations the 'non-competent authority approved package types' are the Excepted Packages and the Industrial Packages of Type IP-1, IP-2 and IP-3 and packages of Type A. For these types of packages an assessment bymore » the competent authority is required for the quality assurance measures for the design, manufacture, testing, documentation, use, maintenance and inspection (IAEA SSR 6, Chap. 306). In general a compliance audit of the manufacturer of the packaging is required during this assessment procedure. Their regulatory level in the IAEA regulations is not comparable with the 'regulatory density' for packages requiring competent authority package design approval. Practices in different countries lead to different approaches within the assessment of the quality assurance measures in the management system as well as in the quality assurance program of a special package design. To use the package or packaging in a safe manner and in compliance with the regulations a management system for each phase of the life of the package or packaging is necessary. The relevant IAEA-SSR6 chap. 801 requires documentary verification by the consignor concerning package compliance with the requirements. (authors)« less
Michalski, Greg; Savarino, Joel; Böhlke, J.K.; Thiemens , Mark
2002-01-01
A thermal decomposition method was developed and tested for the simultaneous determination of δ18O and δ17Ο in nitrate. The thermal decomposition of AgNO3 allows for the rapid and accurate determination of 18O/16O and 17O/16O isotopic ratios with a precision of ±1.5‰ for δ18O and ±0.11‰ for Δ17Ο (Δ17Ο = δ17Ο − 0.52 × δ18O). The international nitrate isotope reference material IAEA-NO3 yielded a δ18O value of +23.6‰ and Δ17Ο of −0.2‰, consistent with normal terrestrial mass-dependent isotopic ratios. In contrast, a large sample of NaNO3 from the Atacama Desert, Chile, was found to have Δ17Ο = 21.56 ± 0.11‰ and δ18O = 54.9 ± 1.5‰, demonstrating a substantial mass-independent isotopic composition consistent with the proposed atmospheric origin of the desert nitrate. It is suggested that this sample (designated USGS-35) can be used to generate other gases (CO2, CO, N2O, O2) with the same Δ17Ο to serve as measurement references for a variety of applications involving mass-independent isotopic compositions in environmental studies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sequis, Julietta E.; Cain, Ronald A.; Burbank, Roberta L.
The Philippines entered into force the International Atomic Energy Agency (IAEA) Additional Protocol (AP) in February 2010. The Philippine Nuclear Research Institute (PNRI) is the government agency responsible for implementing the AP. In June 2010 the IAEA invited the U.S. Department of Energy (DOE) to help conduct a joint national training seminar on the AP. DOE presented to PNRI its AP international technical assistance program, administered by the International Nuclear Safeguards and Engagement Program (INSEP), which helps partner countries implement the AP. In coordination with the IAEA, DOE established this program in 2008 to complement IAEA AP seminars with long-termmore » country-specific cooperation from the perspective of a Member State. The US version of the AP is the same version as that of non-nuclear weapon states except for the addition of a national security exclusion. Due to this, DOE cooperation with other countries enables the sharing of valuable lessons learned in implementing the AP. DOE/INSEP described to PNRI the various areas of cooperation it offers to interested countries, whether they are preparing for entry into force or already implementing the AP. Even countries that have entered the AP into force are sometimes not fully prepared to implement it well, and welcome cooperation to improve their implementation process. PNRI and DOE/INSEP subsequently agreed to cooperate in several areas to enhance the efficiency and effectiveness of the Philippines AP implementation. These areas include providing working-level training to PNRI staff and preparing an information document that details that training for future reference, assisting with the development of an outreach program and procedures for AP reporting and complementary access, and identifying Annex II equipment and non-nuclear materials whose export must be reported under the AP. DOE laboratory representatives, funded by INSEP, met again with PNRI in February 2011 to provide training for PNRI AP staff and investigate specific ways to improve implementation. Another meeting in July 2011 focused on preparations for outreach to industry and universities. In this paper PNRI describes current implementation of the AP in the Philippines, and both DOE/INSEP and PNRI provide their perspectives on their cooperation to enhance that implementation.« less
40 CFR 418.71 - Specialized definitions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... this subpart. (b) The term mixed fertilizer shall mean a mixture of wet and/or dry straight fertilizer materials, mixed fertilizer materials, fillers and additives prepared through chemical reaction to a given... STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Mixed and Blend Fertilizer Production Subcategory...
40 CFR 418.71 - Specialized definitions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... this subpart. (b) The term mixed fertilizer shall mean a mixture of wet and/or dry straight fertilizer materials, mixed fertilizer materials, fillers and additives prepared through chemical reaction to a given... STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Mixed and Blend Fertilizer Production Subcategory...
40 CFR 418.71 - Specialized definitions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... this subpart. (b) The term mixed fertilizer shall mean a mixture of wet and/or dry straight fertilizer materials, mixed fertilizer materials, fillers and additives prepared through chemical reaction to a given... STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Mixed and Blend Fertilizer Production Subcategory...
40 CFR 418.71 - Specialized definitions.
Code of Federal Regulations, 2012 CFR
2012-07-01
... apply to this subpart. (b) The term mixed fertilizer shall mean a mixture of wet and/or dry straight fertilizer materials, mixed fertilizer materials, fillers and additives prepared through chemical reaction to... AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Mixed and Blend Fertilizer Production...
40 CFR 418.71 - Specialized definitions.
Code of Federal Regulations, 2014 CFR
2014-07-01
... this subpart. (b) The term mixed fertilizer shall mean a mixture of wet and/or dry straight fertilizer materials, mixed fertilizer materials, fillers and additives prepared through chemical reaction to a given... STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Mixed and Blend Fertilizer Production Subcategory...
10 CFR 75.8 - IAEA inspections.
Code of Federal Regulations, 2010 CFR
2010-01-01
... inspection at a facility, to: (1) Examine records kept under § 75.21; (2) Observe that the measurements of nuclear material at key measurement points for material balance accounting are representative; (3) Verify... samples at key measurement points for material balance accounting are taken in accordance with procedures...
Kokaly, Raymond F.; King, Trude V.V.; Hoefen, Todd M.; Livo, Keith E.; Johnson, Michaela R.; Giles, Stuart A.
2013-01-01
This map shows the spatial distribution of selected carbonates, phyllosilicates, sulfates, altered minerals, and other materials derived from analysis of airborne HyMap™ imaging spectrometer (hyperspectral) data of Afghanistan collected in late 2007. The map is one in a series of U.S. Geological Survey/Afghanistan Geological Survey quadrangle maps covering Afghanistan. Flown at an altitude of 50,000 feet (15,240 meters (m)), the HyMap™ imaging spectrometer measured reflected sunlight in 128 channels, covering wavelengths between 0.4 and 2.5 μm. The data were georeferenced, atmospherically corrected and converted to apparent surface reflectance, empirically adjusted using ground-based reflectance measurements, and combined into a mosaic with 23-m pixel spacing. Variations in water vapor and dust content of the atmosphere, in solar angle, and in surface elevation complicated correction; therefore, some classification differences may be present between adjacent flight lines. The reflectance spectrum of each pixel of HyMap™ imaging spectrometer data was compared to the reference materials in a spectral library of minerals, vegetation, water, and other materials. Minerals occurring abundantly at the surface and those having unique spectral features were easily detected and discriminated, while minerals having slightly different compositions but similar spectral features were less easily discriminated; thus, some map classes consist of several minerals having similar spectra, such as “Epidote or chlorite.” A designation of “Not classified” was assigned to the pixel when there was no match with reference spectra.
Qi, Haiping; Coplen, Tyler B.; Mroczkowski, Stanley J.; Brand, Willi A.; Brandes, Lauren; Geilmann, Heike; Schimmelmann, Arndt
2016-01-01
RationaleThe widely used l-glutamic acid isotopic reference material USGS41, enriched in both 13C and 15N, is nearly exhausted. A new material, USGS41a, has been prepared as a replacement for USGS41.MethodsUSGS41a was prepared by dissolving analytical grade l-glutamic acid enriched in 13C and 15N together with l-glutamic acid of normal isotopic composition. The δ13C and δ15N values of USGS41a were directly or indirectly normalized with the international reference materials NBS 19 calcium carbonate (δ13CVPDB = +1.95 mUr, where milliurey = 0.001 = 1 ‰), LSVEC lithium carbonate (δ13CVPDB = −46.6 mUr), and IAEA-N-1 ammonium sulfate (δ15NAir = +0.43 mUr) and USGS32 potassium nitrate (δ15N = +180 mUr exactly) by on-line combustion, continuous-flow isotope-ratio mass spectrometry, and off-line dual-inlet isotope-ratio mass spectrometry.ResultsUSGS41a is isotopically homogeneous; the reproducibility of δ13C and δ15N is better than 0.07 mUr and 0.09 mUr, respectively, in 200-μg amounts. It has a δ13C value of +36.55 mUr relative to VPDB and a δ15N value of +47.55 mUr relative to N2 in air. USGS41 was found to be hydroscopic, probably due to the presence of pyroglutamic acid. Experimental results indicate that the chemical purity of USGS41a is substantially better than that of USGS41.ConclusionsThe new isotopic reference material USGS41a can be used with USGS40 (having a δ13CVPDB value of −26.39 mUr and a δ15NAir value of −4.52 mUr) for (i) analyzing local laboratory isotopic reference materials, and (ii) quantifying drift with time, mass-dependent isotopic fractionation, and isotope-ratio-scale contraction for isotopic analysis of biological and organic materials. Published in 2016. This article is a U.S. Government work and is in the public domain in the USA.
Qi, Haiping; Coplen, Tyler B; Mroczkowski, Stanley J; Brand, Willi A; Brandes, Lauren; Geilmann, Heike; Schimmelmann, Arndt
2016-04-15
The widely used l-glutamic acid isotopic reference material USGS41, enriched in both (13) C and (15) N, is nearly exhausted. A new material, USGS41a, has been prepared as a replacement for USGS41. USGS41a was prepared by dissolving analytical grade l-glutamic acid enriched in (13) C and (15) N together with l-glutamic acid of normal isotopic composition. The δ(13) C and δ(15) N values of USGS41a were directly or indirectly normalized with the international reference materials NBS 19 calcium carbonate (δ(13) CVPDB = +1.95 mUr, where milliurey = 0.001 = 1 ‰), LSVEC lithium carbonate (δ(13) CVPDB = -46.6 mUr), and IAEA-N-1 ammonium sulfate (δ(15) NAir = +0.43 mUr) and USGS32 potassium nitrate (δ(15) N = +180 mUr exactly) by on-line combustion, continuous-flow isotope-ratio mass spectrometry, and off-line dual-inlet isotope-ratio mass spectrometry. USGS41a is isotopically homogeneous; the reproducibility of δ(13) C and δ(15) N is better than 0.07 mUr and 0.09 mUr, respectively, in 200-μg amounts. It has a δ(13) C value of +36.55 mUr relative to VPDB and a δ(15) N value of +47.55 mUr relative to N2 in air. USGS41 was found to be hydroscopic, probably due to the presence of pyroglutamic acid. Experimental results indicate that the chemical purity of USGS41a is substantially better than that of USGS41. The new isotopic reference material USGS41a can be used with USGS40 (having a δ(13) CVPDB value of -26.39 mUr and a δ(15) NAir value of -4.52 mUr) for (i) analyzing local laboratory isotopic reference materials, and (ii) quantifying drift with time, mass-dependent isotopic fractionation, and isotope-ratio-scale contraction for isotopic analysis of biological and organic materials. Published in 2016. This article is a U.S. Government work and is in the public domain in the USA. Published in 2016. This article is a U.S. Government work and is in the public domain in the USA.
10 CFR Appendix M to Part 110 - Categorization of Nuclear Material d
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 2 2012-01-01 2012-01-01 false Categorization of Nuclear Material d M Appendix M to Part 110 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) EXPORT AND IMPORT OF NUCLEAR EQUIPMENT AND MATERIAL Pt. 110, App. M Appendix M to Part 110—Categorization of Nuclear Material d [From IAEA INFCIRC/225...
10 CFR Appendix M to Part 110 - Categorization of Nuclear Material d
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 2 2010-01-01 2010-01-01 false Categorization of Nuclear Material d M Appendix M to Part 110 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) EXPORT AND IMPORT OF NUCLEAR EQUIPMENT AND MATERIAL Pt. 110, App. M Appendix M to Part 110—Categorization of Nuclear Material d [From IAEA INFCIRC/225...
10 CFR Appendix M to Part 110 - Categorization of Nuclear Material d
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 2 2013-01-01 2013-01-01 false Categorization of Nuclear Material d M Appendix M to Part 110 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) EXPORT AND IMPORT OF NUCLEAR EQUIPMENT AND MATERIAL Pt. 110, App. M Appendix M to Part 110—Categorization of Nuclear Material d [From IAEA INFCIRC/225...
10 CFR Appendix M to Part 110 - Categorization of Nuclear Material d
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 2 2014-01-01 2014-01-01 false Categorization of Nuclear Material d M Appendix M to Part 110 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) EXPORT AND IMPORT OF NUCLEAR EQUIPMENT AND MATERIAL Pt. 110, App. M Appendix M to Part 110—Categorization of Nuclear Material d [From IAEA INFCIRC/225...
10 CFR Appendix M to Part 110 - Categorization of Nuclear Material d
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 2 2011-01-01 2011-01-01 false Categorization of Nuclear Material d M Appendix M to Part 110 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) EXPORT AND IMPORT OF NUCLEAR EQUIPMENT AND MATERIAL Pt. 110, App. M Appendix M to Part 110—Categorization of Nuclear Material d [From IAEA INFCIRC/225...
NOTE: Monte Carlo simulation of correction factors for IAEA TLD holders
NASA Astrophysics Data System (ADS)
Hultqvist, Martha; Fernández-Varea, José M.; Izewska, Joanna
2010-03-01
The IAEA standard thermoluminescent dosimeter (TLD) holder has been developed for the IAEA/WHO TLD postal dose program for audits of high-energy photon beams, and it is also employed by the ESTRO-QUALity assurance network (EQUAL) and several national TLD audit networks. Factors correcting for the influence of the holder on the TL signal under reference conditions have been calculated in the present work from Monte Carlo simulations with the PENELOPE code for 60Co γ-rays and 4, 6, 10, 15, 18 and 25 MV photon beams. The simulation results are around 0.2% smaller than measured factors reported in the literature, but well within the combined standard uncertainties. The present study supports the use of the experimentally obtained holder correction factors in the determination of the absorbed dose to water from the TL readings; the factors calculated by means of Monte Carlo simulations may be adopted for the cases where there are no measured data.
Reference Cross Sections for Charged-particle Monitor Reactions
NASA Astrophysics Data System (ADS)
Hermanne, A.; Ignatyuk, A. V.; Capote, R.; Carlson, B. V.; Engle, J. W.; Kellett, M. A.; Kibédi, T.; Kim, G.; Kondev, F. G.; Hussain, M.; Lebeda, O.; Luca, A.; Nagai, Y.; Naik, H.; Nichols, A. L.; Nortier, F. M.; Suryanarayana, S. V.; Takács, S.; Tárkányi, F. T.; Verpelli, M.
2018-02-01
Evaluated cross sections of beam-monitor reactions are expected to become the de-facto standard for cross-section measurements that are performed over a very broad energy range in accelerators in order to produce particular radionuclides for industrial and medical applications. The requirements for such data need to be addressed in a timely manner, and therefore an IAEA coordinated research project was launched in December 2012 to establish or improve the nuclear data required to characterise charged-particle monitor reactions. An international team was assembled to recommend more accurate cross-section data over a wide range of targets and projectiles, undertaken in conjunction with a limited number of measurements and more extensive evaluations of the decay data of specific radionuclides. Least-square evaluations of monitor-reaction cross sections including uncertainty quantification have been undertaken for charged-particle beams of protons, deuterons, 3He- and 4He-particles. Recommended beam monitor reaction data with their uncertainties are available at the IAEA-NDS medical portal http://www-nds.iaea.org/medical/monitor_reactions.html.
A soil sampling intercomparison exercise for the ALMERA network.
Belli, Maria; de Zorzi, Paolo; Sansone, Umberto; Shakhashiro, Abduhlghani; Gondin da Fonseca, Adelaide; Trinkl, Alexander; Benesch, Thomas
2009-11-01
Soil sampling and analysis for radionuclides after an accidental or routine release is a key factor for the dose calculation to members of the public, and for the establishment of possible countermeasures. The IAEA organized for selected laboratories of the ALMERA (Analytical Laboratories for the Measurement of Environmental Radioactivity) network a Soil Sampling Intercomparison Exercise (IAEA/SIE/01) with the objective of comparing soil sampling procedures used by different laboratories. The ALMERA network is a world-wide network of analytical laboratories located in IAEA member states capable of providing reliable and timely analysis of environmental samples in the event of an accidental or intentional release of radioactivity. Ten ALMERA laboratories were selected to participate in the sampling exercise. The soil sampling intercomparison exercise took place in November 2005 in an agricultural area qualified as a "reference site", aimed at assessing the uncertainties associated with soil sampling in agricultural, semi-natural, urban and contaminated environments and suitable for performing sampling intercomparison. In this paper, the laboratories sampling performance were evaluated.
Towards absolute laser spectroscopic CO2 isotope ratio measurements
NASA Astrophysics Data System (ADS)
Anyangwe Nwaboh, Javis; Werhahn, Olav; Ebert, Volker
2017-04-01
Knowledge of isotope composition of carbon dioxide (CO2) in the atmosphere is necessary to identify sources and sinks of this key greenhouse gas. In the last years, laser spectroscopic techniques such as cavity ring-down spectroscopy (CRDS) and tunable diode laser absorption spectroscopy (TDLAS) have been shown to perform accurate isotope ratio measurements for CO2 and other gases like water vapour (H2O) [1,2]. Typically, isotope ratios are reported in literature referring to reference materials provided by e.g. the International Atomic Energy Agency (IAEA). However, there could be some benefit if field deployable absolute isotope ratio measurement methods were developed to address issues such as exhausted reference material like the Pee Dee Belemnite (PDB) standard. Absolute isotope ratio measurements would be particularly important for situations where reference materials do not even exist. Here, we present CRDS and TDLAS-based absolute isotope ratios (13C/12C ) in atmospheric CO2. We demonstrate the capabilities of the used methods by measuring CO2 isotope ratios in gas standards. We compare our results to values reported for the isotope certified gas standards. Guide to the expression of uncertainty in measurement (GUM) compliant uncertainty budgets on the CRDS and TDLAS absolute isotope ratio measurements are presented, and traceability is addressed. We outline the current impediments in realizing high accuracy absolute isotope ratio measurements using laser spectroscopic methods, propose solutions and the way forward. Acknowledgement Parts of this work have been carried out within the European Metrology Research Programme (EMRP) ENV52 project-HIGHGAS. The EMRP is jointly funded by the EMRP participating countries within EURAMET and the European Union. References [1] B. Kühnreich, S. Wagner, J. C. Habig,·O. Möhler, H. Saathoff, V. Ebert, Appl. Phys. B 119:177-187 (2015). [2] E. Kerstel, L. Gianfrani, Appl. Phys. B 92, 439-449 (2008).
20 CFR 410.418 - Irrebuttable presumption of total disability due to pneumoconiosis.
Code of Federal Regulations, 2011 CFR
2011-04-01
... Classification of Radiographs of Pneumoconioses, 1971, or (2) The International Classification of the Radiographs of the Pneumoconioses of the International Labour Office, Extended Classification (1968) (which may be referred to as the “ILO Classification (1968)”), or (3) The Classification of the Pneumoconiosis...
Shabana, E I; Al-Shammari, H L
2001-01-01
A radiochemical technique for determination of plutonium isotopes and 241Am in soil samples is tested against IAEA-standard reference materials to determine its accuracy and precision for reliable results. The technique is then used in the investigation of topsoil samples, collected from the natural environment of the central region of Saudi Arabia, to assess the effect of fallout accumulation of these radionuclides in the region. Plutonium and americium were sequentially separated from all other components of the sample by anion-exchange chromatography and co-precipitated with Nd3+ as fluorides. The precipitates were mounted on membrane filters and measured using a high-resolution alpha-spectrometer. The results of the analysis of the reference materials showed satisfactory sensitivity and precision of the technique. The results of the analyzed soil samples show activity levels ranging from < LLD to 0.089 and from
Reducing the risks from radon indoors: an IAEA perspective.
Boal, T; Colgan, P A
2014-07-01
The IAEA has a mandate to develop, in collaboration with other relevant international organisations, 'standards of safety for protection of health and minimisation of danger to life and property', and to provide for the application of these standards. The most recent edition of the International Basic Safety Standards includes, for the first time, requirements to protect the public from exposure due to radon indoors. As a result, the IAEA has already developed guidance material in line with accepted best international practice and an international programme to assist its Member States in identifying and addressing high radon concentrations in buildings is being prepared. This paper overviews the current situation around the world and summarises the management approach advocated by the IAEA. A number of important scientific and policy issues are identified and discussed from the point-of-view of how they may impact on national action plans and strategies. Finally, the assistance and support available through the Agency is described. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Front-end Electronics for Unattended Measurement (FEUM). Results of Prototype Evaluation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Conrad, Ryan C.; Keller, Daniel T.; Morris, Scott J.
2015-07-01
The International Atomic Energy Agency (IAEA) deploys unattended monitoring systems to provide continuous monitoring of nuclear material within safeguarded facilities around the world. As the number of unattended monitoring instruments increases, the IAEA is challenged to become more efficient in the implementation of those systems. In 2010, the IAEA initiated the Front-End Electronics for Unattended Measurement (FEUM) project with the goals of greater flexibility in the interfaces to various sensors and data acquisition systems, and improved capabilities for remotely located sensors (e.g., where sensor and front-end electronics might be separated by tens of meters). In consultation with the IAEA, amore » technical evaluation of a candidate FEUM device produced by a commercial vendor has been performed. This evaluation assessed the device against the IAEA’s original technical specifications and a broad range of important parameters that include sensor types, cable lengths and types, industrial electromagnetic noise that can degrade signals from remotely located detectors, and high radiation fields. Testing data, interpretation, findings and recommendations are provided.« less
Training of interventional cardiologists in radiation protection--the IAEA's initiatives.
Rehani, Madan M
2007-01-08
The International Atomic Energy Agency (IAEA) has initiated a major international initiative to train interventional cardiologists in radiation protection as a part of its International Action Plan on the radiological protection of patients. A simple programme of two days' training has been developed, covering possible and observed radiation effects among patients and staff, international standards, dose management techniques, examples of good and bad practice and examples indicating prevention of possible injuries as a result of good practice of radiation protection. The training material is freely available on CD from the IAEA. The IAEA has conducted two events in 2004 and 2005 and number of events are planned in 2006. The survey conducted among the cardiologists participating in these programmes indicates that over 80% of them were attending such a structured programme on radiation protection for the first time. As the magnitude of X-ray usage in cardiology grows to match that in interventional radiology, the standards of training on radiation effects, radiation physics and radiation protection in interventional cardiology should also match those in interventional radiology.
Safe transport of radioactive materials in Egypt
NASA Astrophysics Data System (ADS)
El-Shinawy, Rifaat M. K.
1994-07-01
In Egypt the national regulations for safe transport of radioactive materials (RAM) are based on the International Atomic Energy Agency (IAEA) regulations. In addition, regulations for the safe transport of these materials through the Suez Canal (SC) were laid down by the Egyptian Atomic Energy Authority (EAEA) and the Suez Canal Authority (SCA). They are continuously updated to meet the increased knowledge and the gained experience. The technical and protective measures taken during transport of RAM through SC are mentioned. Assessment of the impact of transporting radioactive materials through the Suez Canal using the INTERTRAN computer code was carried out in cooperation with IAEA. The transported activities and empty containers, the number of vessels carrying RAM through the canal from 1963 to 1991 and their nationalities are also discussed. The protective measures are mentioned.A review of the present situation of the radioactive wastes storage facilities at the Atomic Energy site at Inshas is given along with the regulation for safe transportation and disposal of radioactive wastes
10 CFR 75.21 - General requirements.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 2 2011-01-01 2011-01-01 false General requirements. 75.21 Section 75.21 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA AGREEMENT Material Accounting and Control for Facilities § 75.21 General requirements. (a) Each licensee or certificate holder...
Hybrid Gama Emission Tomography (HGET): FY16 Annual Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, Erin A.; Smith, Leon E.; Wittman, Richard S.
2017-02-01
Current International Atomic Energy Agency (IAEA) methodologies for the verification of fresh low-enriched uranium (LEU) and mixed oxide (MOX) fuel assemblies are volume-averaging methods that lack sensitivity to individual pins. Further, as fresh fuel assemblies become more and more complex (e.g., heavy gadolinium loading, high degrees of axial and radial variation in fissile concentration), the accuracy of current IAEA instruments degrades and measurement time increases. Particularly in light of the fact that no special tooling is required to remove individual pins from modern fuel assemblies, the IAEA needs new capabilities for the verification of unirradiated (i.e., fresh LEU and MOX)more » assemblies to ensure that fissile material has not been diverted. Passive gamma emission tomography has demonstrated potential to provide pin-level verification of spent fuel, but gamma-ray emission rates from unirradiated fuel emissions are significantly lower, precluding purely passive tomography methods. The work presented here introduces the concept of Hybrid Gamma Emission Tomography (HGET) for verification of unirradiated fuels, in which a neutron source is used to actively interrogate the fuel assembly and the resulting gamma-ray emissions are imaged using tomographic methods to provide pin-level verification of fissile material concentration.« less
Determination of δ18O and δ15N in Nitrate
Revesz, K.; Böhlke, J.K.; Yoshinari, T.
1997-01-01
The analyses of both O and N isotopic compositions of nitrate have many potential applications in studies of nitrate sources and reactions in hydrology, oceanography, and atmospheric chemistry, but simple and precise methods for these analyses have yet to be developed. Testing of a new method involving reaction of potassium nitrate with catalyzed graphite (C + Pd + Au) at 520 °C resulted in quantitative recovery of N and O from nitrate as free CO2, K2CO3, and N2. The δ18O values of nitrate reference materials were obtained by analyzing both the CO2 and K2CO3 from catalyzed graphite combustion. Provisional values of δ18OVSMOW for the internationally distributed KNO3 reference materials IAEA-N3 and USGS-32 were both equal to +22.7 ± 0.5‰. Because the fraction of free CO2 and the isotopic fractionation factor between CO2 and K2CO3 were constant in the combustion products, the δ18O value of KNO3 could be calculated from measurements of the δ18O of free CO2. Thus, δ18OKNO3 = aδ18Ofree CO2 − b, where a and b were equal to 0.9967 and 3.3, respectively, for the specific conditions of the experiments. The catalyzed graphite combustion method can be used to determine δ18O of KNO3 from measurements of δ18O of free CO2 with reproducibility on the order of ±0.2‰ or better if local reference materials are prepared and analyzed with the samples. Reproducibility of δ15N was ±0.1‰ after trace amounts of CO were removed.
Spent fuel measurements. passive neutron albedo reactivity (PNAR) and photon signatures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eigenbrodt, Julia; Menlove, Howard Olsen
2016-03-29
The International Atomic Energy Agency’s (IAEA) safeguards technical objective is the timely detection of a diversion of a significant quantity of nuclear material from peaceful activities to the manufacture of nuclear weapons or of other nuclear explosive devices or for purposes unknown, and deterrence of such diversion by the risk of early detection. An important IAEA task towards meeting this objective is the ability to accurately and reliably measure spent nuclear fuel (SNF) to verify reactor operating parameters and verify that the fuel has not been removed from reactors or SNF storage facilities. This dissertation analyzes a method to improvemore » the state-of-the-art of nuclear material safeguards measurements using two combined measurement techniques: passive neutron albedo reactivity (PNAR) and passive spectral photon measurements.« less
Mullahs, Guards, and Bonyads: An Exploration of Iranian Leadership Dynamics
2009-01-01
Rafsanjani, the foundation became a huge con- glomerate of multiple businesses and industries, including tourism , real estate, agriculture, petrochemicals...facility at Natanz in particular, were made public, there was a clear risk that the IAEA Board of Gover - nors would refer the matter to the UN Security
10 CFR 75.15 - Facility attachments.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 2 2011-01-01 2011-01-01 false Facility attachments. 75.15 Section 75.15 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA AGREEMENT Material... under Article 39(b) of the main text of the Safeguards Agreement, do not have Facility Attachments or...
10 CFR 75.15 - Facility attachments.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 2 2010-01-01 2010-01-01 false Facility attachments. 75.15 Section 75.15 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA AGREEMENT Material... under Article 39(b) of the main text of the Safeguards Agreement, do not have Facility Attachments or...
10 CFR 75.22 - Accounting records.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 2 2011-01-01 2011-01-01 false Accounting records. 75.22 Section 75.22 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA AGREEMENT Material Accounting and Control for Facilities § 75.22 Accounting records. (a) The accounting records required by § 75...
10 CFR 75.23 - Operating records.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 2 2011-01-01 2011-01-01 false Operating records. 75.23 Section 75.23 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA AGREEMENT Material Accounting and Control for Facilities § 75.23 Operating records. The operating records required by § 75.21...
Results for Phase I of the IAEA Coordinated Research Program on HTGR Uncertainties
DOE Office of Scientific and Technical Information (OSTI.GOV)
Strydom, Gerhard; Bostelmann, Friederike; Yoon, Su Jong
2015-01-01
The quantification of uncertainties in design and safety analysis of reactors is today not only broadly accepted, but in many cases became the preferred way to replace traditional conservative analysis for safety and licensing analysis. The use of a more fundamental methodology is also consistent with the reliable high fidelity physics models and robust, efficient, and accurate codes available today. To facilitate uncertainty analysis applications a comprehensive approach and methodology must be developed and applied. High Temperature Gas-cooled Reactors (HTGR) has its own peculiarities, coated particle design, large graphite quantities, different materials and high temperatures that also require other simulationmore » requirements. The IAEA has therefore launched a Coordinated Research Project (CRP) on the HTGR Uncertainty Analysis in Modeling (UAM) in 2013 to study uncertainty propagation specifically in the HTGR analysis chain. Two benchmark problems are defined, with the prismatic design represented by the General Atomics (GA) MHTGR-350 and a 250 MW modular pebble bed design similar to the HTR-PM (INET, China). This report summarizes the contributions of the HTGR Methods Simulation group at Idaho National Laboratory (INL) up to this point of the CRP. The activities at INL have been focused so far on creating the problem specifications for the prismatic design, as well as providing reference solutions for the exercises defined for Phase I. An overview is provided of the HTGR UAM objectives and scope, and the detailed specifications for Exercises I-1, I-2, I-3 and I-4 are also included here for completeness. The main focus of the report is the compilation and discussion of reference results for Phase I (i.e. for input parameters at their nominal or best-estimate values), which is defined as the first step of the uncertainty quantification process. These reference results can be used by other CRP participants for comparison with other codes or their own reference results. The status on the Monte Carlo modeling of the experimental VHTRC facility is also discussed. Reference results were obtained for the neutronics stand-alone cases (Ex. I-1 and Ex. I-2) using the (relatively new) Monte Carlo code Serpent, and comparisons were performed with the more established Monte Carlo codes MCNP and KENO-VI. For the thermal-fluids stand-alone cases (Ex. I-3 and I-4) the commercial CFD code CFX was utilized to obtain reference results that can be compared with lower fidelity tools.« less
Shekhar, R
2012-05-15
A method has been developed to improve the sensitivity of the electrolyte cathode discharge atomic emission spectrometry (ELCAD-AES) for mercury determination. Effects of various low molecular weight organic solvents at different volume percentages as well as at different acid molarities on the mercury signal were investigated using ELCAD-AES. The addition of few percent of organic solvent, acetic acid produced significant enhancement in mercury signal. Acetic acid of 5% (v/v) with the 0.2M acidity has been found to give 500% enhancement for mercury signal in flow injection mode. Under the optimized parameters the repeatability, expressed as the percentage relative standard deviation of spectral peak area for mercury with 5% acetic acid was found to be 10% for acid blank solution and 5% for 20 ng/mL mercury standard based on multiple measurements with a multiple sample loading in flow injection mode. Limit of detection of this method was determined to be 2 ng/mL for inorganic mercury. The proposed method has been validated by determining mercury in certified reference materials, Tuna fish (IAEA-350) and Aquatic plant (BCR-060). Accuracy of the method for the mercury determination in the reference materials has been found to be between 3.5% and 5.9%. This study enhances the utility of ELCAD-AES for various types of biological and environmental materials to quantify total mercury at very low levels. Copyright © 2012 Elsevier B.V. All rights reserved.
Rahman, Md Sajjadur; Hossain, Syed Mohammod; Rahman, Mir Tamzid; Halim, Mohammad A; Ishtiak, Mohammad Niaz; Kabir, Mahbub
2017-11-08
Leaching of toxic metals from fertilizers is a growing concern in an agricultural country like Bangladesh due to the serious consequences in health and food chain. Fertilizers used in farming fields and nurseries (plant sales outlet) in the mid-southern part of Bangladesh were collected for the determination of toxic metals. This study employed the neutron activation method and a relative standardization approach. Three standard/certified reference materials, namely NIST coal fly ash 1633b, IAEA-Soil-7, and IAEA-SL-1 (lake sediment), were considered for elemental quantification. Concentration of As (2.63-16.73 mg/kg), Cr (40.93-261.77 mg/kg), Sb (0.47-63.58 mg/kg), Th (1.44-19.16 mg/kg), and U (1.90-209.41 mg/kg) were determined in fertilizers. High concentrations of Cr, Sb, and U were detected in some compost and phosphate fertilizers (TSP and diammonium phosphate (DAP)) in comparison with the IAEA/European market standard and other studies. Quantum mechanical calculations were performed to understand the molecular level interaction of CrO 3 , Sb 2 O 3 , and AsO 3 , with DAP by employing density functional theory with the B3LYP/SDD level of theory. Our results indicated that CrO 3 and Sb 2 O 3 have strong binding affinity with DAP compared to AsO 3 , which supports the experimental results. These compounds attached to the phosphate group through covalent-like bonding with oxygen. The frontier molecular orbital calculation indicated that HOMO-LUMO gap of the AsO 3 -DAP (5.46 eV) and Sb 2 O 3 -DAP (6.48 eV) complexes are relatively lower than the CrO 3 -DAP, which indicates that As and Sb oxides are chemically more prone to attach with the phosphate group of DAP fertilizer.
40 CFR 418.41 - Specialized definitions.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart. (b) The term product shall mean the 100 percent ammonium nitrate content of the material manufactured. (Sec. 306(b...
40 CFR 418.31 - Specialized definitions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart. (b) The term product shall mean the 100 percent urea content of the material manufactured. (Sec. 306(b), Federal Water...
Regional Seminars to Address Current Nuclear Export Control Issues
DOE Office of Scientific and Technical Information (OSTI.GOV)
Killinger, Mark H.
2002-07-01
The control of nuclear-related exports, a critical component of the nonproliferation regime, is facing several opportunities and challenges. As countries sign and ratify the International Atomic Energy Agency's (IAEA) safeguards Additional Protocol (AP), they will begin to report far more export information, including exports of a list of items similar to the Nuclear Supplier Group's Trigger List that existed when the AP was developed in the mid-1990s. This positive development contrasts with challenges such as globalization, transshipments, and tracking of end-uses. Pacific Northwest National Laboratory is proposing that the US Department of Energy (DOE) develop regional seminars that address thesemore » types of issues related to export/import controls. The DOE seminars would be designed to supplement regional seminars sponsored by the IAEA and member states on topics related to the Additional Protocol (referred to as "IAEA seminars"). The topic of nuclear export/import controls is not thoroughly addressed in the IAEA seminars. The proposed DOE seminars would therefore have two objectives: familiarizing countries with the export/import provisions of the Additional Protocol, and addressing challenges such as those noted above. The seminars would be directed particularly at countries that have not ratified the AP, and at regions where export-related problems are particularly prevalent. The intent is to encourage governments to implement more effective nuclear export control systems that meet the challenges of the 21st century.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, M. E.; Jones, T. M.; Miller, D. H.
Several Slurry-Fed Melt Rate Furnace (SMRF) tests with earlier projections of the Sludge Batch 4 (SB4) composition have been performed.1,2 The first SB4 SMRF test used Frits 418 and 320, however it was found after the test that the REDuction/OXidation (REDOX) correlation at that time did not have the proper oxidation state for manganese. Because the manganese level in the SB4 sludge was higher than previous sludge batches tested, the impact of the higher manganese oxidation state was greater. The glasses were highly oxidized and very foamy, and therefore the results were inconclusive. After resolving this REDOX issue, Frits 418,more » 425, and 503 were tested in the SMRF with the updated baseline SB4 projection. Based on dry-fed Melt Rate Furnace (MRF) tests and the above mentioned SMRF tests, two previous frit recommendations were made by the Savannah River National Laboratory (SRNL) for processing of SB4 in the Defense Waste Processing Facility (DWPF). The first was Frit 503 based on the June 2006 composition projections.3 The recommendation was changed to Frit 418 as a result of the October 2006 composition projections (after the Tank 40 decant was implemented as part of the preparation plan). However, the start of SB4 processing was delayed due to the control room consolidation outage and the repair of the valve box in the Tank 51 to Tank 40 transfer line. These delays resulted in changes to the projected SB4 composition. Due to the slight change in composition and based on preliminary dry-fed MRF testing, SRNL believed that Frit 510 would increase throughput in processing SB4 in DWPF. Frit 418, which was used in processing Sludge Batch 3 (SB3), was a viable candidate and available in DWPF. Therefore, it was used during the initial SB4 processing. Due to the potential for higher melt rates with Frit 510, SMRF tests with the latest SB4 composition (1298 canisters) and Frits 510 and 418 were performed at a targeted waste loading (WL) of 35%. The '1298 canisters' describes the number of equivalent canisters that would be produced from the beginning of the current contract period before SB3 is blended with SB4. The melt rate for the SMRF SB4/Frit 510 test was 14.6 grams/minute. Due to cold cap mounding problems with the SMRF SB4/Frit 418 feed at 50 weight % solids that prevented a melt rate determination, this feed was diluted to 45 weight % solids. The melt rate for this diluted feed was 8.9 grams/minute. A correction factor of 1.2 for estimating the melt rate at 50 weight % solids from 45 weight % solids test results (based on previous SMRF testing5) was then used to estimate a melt rate of 10.7 grams/minute for SB4/Frit 418 at 50 weight % solids. Therefore, the use of Frit 510 versus Frit 418 with SB4 resulted in a higher melt rate (14.6 versus an estimated 10.7 grams/minute). For reference, a previous SMRF test with SB3/Frit 418 feed at 35% waste loading and 50 weight % solids resulted in a melt rate of 14.1 grams/minute. Therefore, depending on the actual feed rheology, the use of Frit 510 with SB4 could result in similar melt rates as experienced with SB3/Frit 418 feed in the DWPF.« less
49 CFR 173.418 - Authorized packages-pyrophoric Class 7 (radioactive) materials.
Code of Federal Regulations, 2010 CFR
2010-10-01
... must not be fissile unless excepted by § 173.453; (b) Contained in sealed and corrosion resistant receptacles with positive closures (friction or slip-fit covers or stoppers are not authorized); (c) Free of...
Near millimeter wave characterization of dual mode materials
NASA Astrophysics Data System (ADS)
Stead, Michael; Simonis, George
1989-05-01
Nine materials which have application to both the millimeter and IR wavelength regions have been analyzed, and their indices of refraction and absorption coefficients have been determined in the 4-18/cm range. The lowest loss materials are found to be ALON and sapphire, and the highest loss samples to be ZnS and ZnSe. The mm-wave indices are all shown to be higher than their corresponding IR indices.
20 CFR 410.418 - Irrebuttable presumption of total disability due to pneumoconiosis.
Code of Federal Regulations, 2010 CFR
2010-04-01
... FEDERAL COAL MINE HEALTH AND SAFETY ACT OF 1969, TITLE IV-BLACK LUNG BENEFITS (1969- ) Total Disability or... suffered from a chronic dust disease of the lung which: (a) When diagnosed by chest roentgenogram (X-ray... of the Union Internationale Contra Cancer/Cincinnati (1968) (which may be referred to as the “UICC...
Rep. Rokita, Todd [R-IN-4
2013-07-23
Senate - 07/15/2014 Received in the Senate and Read twice and referred to the Committee on Homeland Security and Governmental Affairs. (All Actions) Tracker: This bill has the status Passed HouseHere are the steps for Status of Legislation:
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-01
... time before the opening of trading in the underlying security when the Hybrid System will accept orders... related language in CBOE Rule 4.18 because the concept of leasing memberships no longer exists after the... Holder''). The Exchange is proposing to delete references to the concept of registering a membership for...
78 FR 16921 - Physical Protection of Byproduct Material
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-19
... 1 and category 2 thresholds are based on the quantities established by the International Atomic... orders that were issued to licensees using a graded approach based on the relative risk and quantity of... 5,400 Ytterbium-169 300 8,100 3 81.0 These materials and thresholds are based on the IAEA Code of...
49 CFR 173.476 - Approval of special form Class 7 (radioactive) materials.
Code of Federal Regulations, 2014 CFR
2014-10-01
... any tests, demonstrating that the special form material meets the requirements of § 173.469. An IAEA... both physical and chemical states; (2) A detailed statement of the capsule design and dimensions..., and methods of construction; (3) A statement of the tests that have been made and their results; or...
49 CFR 173.476 - Approval of special form Class 7 (radioactive) materials.
Code of Federal Regulations, 2012 CFR
2012-10-01
... tests, demonstrating that the special form material meets the requirements of § 173.469. An IAEA... both physical and chemical states; (2) A detailed statement of the capsule design and dimensions..., and methods of construction; (3) A statement of the tests that have been made and their results; or...
49 CFR 173.476 - Approval of special form Class 7 (radioactive) materials.
Code of Federal Regulations, 2013 CFR
2013-10-01
... tests, demonstrating that the special form material meets the requirements of § 173.469. An IAEA... both physical and chemical states; (2) A detailed statement of the capsule design and dimensions..., and methods of construction; (3) A statement of the tests that have been made and their results; or...
49 CFR 173.476 - Approval of special form Class 7 (radioactive) materials.
Code of Federal Regulations, 2010 CFR
2010-10-01
... tests, demonstrating that the special form material meets the requirements of § 173.469. An IAEA... both physical and chemical states; (2) A detailed statement of the capsule design and dimensions..., and methods of construction; (3) A statement of the tests that have been made and their results; or...
49 CFR 173.476 - Approval of special form Class 7 (radioactive) materials.
Code of Federal Regulations, 2011 CFR
2011-10-01
... tests, demonstrating that the special form material meets the requirements of § 173.469. An IAEA... both physical and chemical states; (2) A detailed statement of the capsule design and dimensions..., and methods of construction; (3) A statement of the tests that have been made and their results; or...
10 CFR 75.10 - Facility information.
Code of Federal Regulations, 2011 CFR
2011-01-01
..., to the extent feasible, to the form, location and flow of nuclear material, and to the general layout... paragraph (b)(5) of this section, must be prepared on IAEA approved Design Information Questionnaire forms...
10 CFR 75.10 - Facility information.
Code of Federal Regulations, 2014 CFR
2014-01-01
..., to the extent feasible, to the form, location and flow of nuclear material, and to the general layout... paragraph (b)(5) of this section, must be prepared on IAEA approved Design Information Questionnaire forms...
10 CFR 75.10 - Facility information.
Code of Federal Regulations, 2012 CFR
2012-01-01
..., to the extent feasible, to the form, location and flow of nuclear material, and to the general layout... paragraph (b)(5) of this section, must be prepared on IAEA approved Design Information Questionnaire forms...
10 CFR 75.10 - Facility information.
Code of Federal Regulations, 2013 CFR
2013-01-01
..., to the extent feasible, to the form, location and flow of nuclear material, and to the general layout... paragraph (b)(5) of this section, must be prepared on IAEA approved Design Information Questionnaire forms...
76 FR 61667 - Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-05
..., including: Mining and milling of nuclear materials; buildings on sites of facilities selected by the IAEA... verify the forms' data. The revision involves text clarifications. Affected Public: Business or other for...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beyer, Brian David; Beddingfield, David H; Durst, Philip
2010-01-01
The design of the Pebble Bed Modular Reactor (PBMR) does not fit or seem appropriate to the IAEA safeguards approach under the categories of light water reactor (LWR), on-load refueled reactor (OLR, i.e. CANDU), or Other (prismatic HTGR) because the fuel is in a bulk form, rather than discrete items. Because the nuclear fuel is a collection of nuclear material inserted in tennis-ball sized spheres containing structural and moderating material and a PBMR core will contain a bulk load on the order of 500,000 spheres, it could be classified as a 'Bulk-Fuel Reactor.' Hence, the IAEA should develop unique safeguardsmore » criteria. In a multi-lab DOE study, it was found that an optimized blend of: (i) developing techniques to verify the plutonium content in spent fuel pebbles, (ii) improving burn-up computer codes for PBMR spent fuel to provide better understanding of the core and spent fuel makeup, and (iii) utilizing bulk verification techniques for PBMR spent fuel storage bins should be combined with the historic IAEA and South African approaches of containment and surveillance to verify and maintain continuity of knowledge of PBMR fuel. For all of these techniques to work the design of the reactor will need to accommodate safeguards and material accountancy measures to a far greater extent than has thus far been the case. The implementation of Safeguards-by-Design as the PBMR design progresses provides an approach to meets these safeguards and accountancy needs.« less
Sonawane, A U; Shirva, V K; Pradhan, A S
2010-02-01
Skin entrance doses (SEDs) were estimated by carrying out measurements of air kerma from 101 X-ray machines installed in 45 major and selected hospitals in the country by using a silicon detector-based dose Test-O-Meter. 1209 number of air kerma measurements of diagnostic projections for adults have been analysed for seven types of common diagnostic examinations, viz. chest (AP, PA, LAT), lumbar spine (AP, LAT), thoracic spine (AP, LAT), abdomen (AP), pelvis (AP), hip joints (AP) and skull (PA, LAT) for different film-screen combinations. The values of estimated diagnostic reference levels (DRLs) (third quartile values of SEDs) were compared with guidance levels/DRLs of doses published by the IAEA-BSS-Safety Series No. 115, 1996; HPA (NRPB) (2000 and 2005), UK; CRCPD/CDRH (USA), European Commission and other national values. The values of DRLs obtained in this study are comparable with the values published by the IAEA-BSS-115 (1996); HPA (NRPB) (2000 and 2005) UK; EC and CRCPD/CDRH, USA including values obtained in previous studies in India.
Safeguards by Design Challenge
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alwin, Jennifer Louise
The International Atomic Energy Agency (IAEA) defines Safeguards as a system of inspection and verification of the peaceful uses of nuclear materials as part of the Nuclear Nonproliferation Treaty. IAEA oversees safeguards worldwide. Safeguards by Design (SBD) involves incorporation of safeguards technologies, techniques, and instrumentation during the design phase of a facility, rather that after the fact. Design challenge goals are the following: Design a system of safeguards technologies, techniques, and instrumentation for inspection and verification of the peaceful uses of nuclear materials. Cost should be minimized to work with the IAEA’s limited budget. Dose to workers should always bemore » as low are reasonably achievable (ALARA). Time is of the essence in operating facilities and flow of material should not be interrupted significantly. Proprietary process information in facilities may need to be protected, thus the amount of information obtained by inspectors should be the minimum required to achieve the measurement goal. Then three different design challenges are detailed: Plutonium Waste Item Measurement System, Marine-based Modular Reactor, and Floating Nuclear Power Plant (FNPP).« less
Use of the ICRP system for the protection of marine ecosystems.
Telleria, D; Cabianca, T; Proehl, G; Kliaus, V; Brown, J; Bossio, C; Van der Wolf, J; Bonchuk, I; Nilsen, M
2015-06-01
The International Commission on Radiological Protection (ICRP) recently reinforced the international system of radiological protection, initially focused on humans, by identifying principles of environmental protection and proposing a framework for assessing impacts of ionising radiation on non-human species, based on a reference flora and fauna approach. For this purpose, ICRP developed dosimetric models for a set of Reference Animals and Plants, which are representative of flora and fauna in different environments (terrestrial, freshwater, marine), and produced criteria based on information on radiation effects, with the aim of evaluating the level of potential or actual radiological impacts, and as an input for decision making. The approach developed by ICRP for flora and fauna is consistent with the approach used to protect humans. The International Atomic Energy Agency (IAEA) includes considerations on the protection of the environment in its safety standards, and is currently developing guidelines to assess radiological impacts based on the aforementioned ICRP approach. This paper presents the method developed by IAEA, in a series of meetings with international experts, to enable assessment of the radiological impact to the marine environment in connection with the Convention on the Prevention of Marine Pollution by Dumping of Wastes and Other Matter 1972 (London Convention 1972). This method is based on IAEA's safety standards and ICRP's recommendations, and was presented in 2013 for consideration by representatives of the contracting parties of the London Convention 1972; it was approved for inclusion in its procedures, and is in the process of being incorporated into guidelines. © The International Society for Prosthetics and Orthotics Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Comparative assessment of essential and heavy metals in fruits from different geographical origins.
Grembecka, Małgorzata; Szefer, Piotr
2013-11-01
The aim of this investigation was to estimate and compare essential and heavy metals contents in 98 commercially available fresh fruits from different geographic regions using multivariate techniques. The concentrations of 12 elements (calcium, magnesium, potassium, sodium, phophorus, cobalt (Co), manganese, iron, chromium (Cr), nickel (Ni), zinc and copper) were determined using flame atomic absorption spectrometry with deuterium-background correction. Phosphorus was determined in the form of phosphomolybdate by a spectrophotometric method. Reliability of the procedure was checked by analysis of the certified reference materials tea (NCS DC 73351), cabbage (IAEA-359) and spinach leaves (NIST-1570). Recoveries of the elements analysed varied between 85.5 and 103%, and precisions for the reference materials were 0.13-6.08%. Based on recommended dietary allowance and adequate intake estimated for essential elements, it was concluded that accessory fruits such as pineapples, raspberries and strawberries supply organism with the highest amounts of bioelements. Although accessory fruits were also found to be the greatest source of Ni among all the analysed fruits, in all the fruits Ni was more abundant than Cr and Co. Significant correlation coefficients (p < 0.001, p < 0.01 and p < 0.05) were found between concentrations of some metals in fresh fruits. Application of ANOVA Kruskal-Wallis test and multivariate techniques such as factor analysis and cluster analysis enabled us to differentiate particular botanical families and types of fruits.
NASA Astrophysics Data System (ADS)
Rasuli, Behrouz; Tabari Juybari, Raheleh; Forouzi, Meysam; Ghorbani, Mohammad
2017-09-01
Introduction: The main purpose of this study was to investigate patient dose in pelvic and abdomen x-ray examinations. This work also provided the LDRLs (local diagnostic reference levels) in Khuzestan region, southwest of Iran to help establish the NDRLs (national diagnostic reference levels). Methods: Patient doses were assessed from patient's anatomical data and exposure parameters based on the IAEA indirect dosimetry method. With regard to this method, exposure parameters such as tube output, kVp, mAs, FFD and patient anatomical data were used for calculating ESD (entrance skin dose) of patients. This study was conducted on 250 standard patients (50% men and 50% women) at eight high-patient-load imaging centers. Results: The results indicate that mean ESDs for the both pelvic and abdomen examinations were lower than the IAEA and EC reference levels, 2.3 and 3.7 mGy, respectively. Mean applied kVps were 67 and 70 and mean FFDs were 103 and 109, respectively. Tube loadings obtained in this study for pelvic examination were lower than all the corresponding values in the reviewed literature. Likewise, the average annual patient load across all hospitals were more than 37000 patients, i.e. more than 100 patients a day. Conclusions: The authors recommend that DRLs (diagnostic reference levels) obtained in this region, which are the first available data, can be used as local DRLs for pelvic and abdomen procedures. This work also provides that on-the-job training programs for staffs and close cross collaboration between physicists and physicians should be strongly considered.
Testing the applicability of the k0-NAA method at the MINT's TRIGA MARK II reactor
NASA Astrophysics Data System (ADS)
Siong, Wee Boon; Dung, Ho Manh; Wood, Ab. Khalik; Salim, Nazaratul Ashifa Abd.; Elias, Md. Suhaimi
2006-08-01
The Analytical Chemistry Laboratory at MINT is using the NAA technique since 1980s and is the only laboratory in Malaysia equipped with a research reactor, namely the TRIGA MARK II. Throughout the years the development of NAA technique has been very encouraging and was made applicable to a wide range of samples. At present, the k0 method has become the preferred standardization method of NAA ( k0-NAA) due to its multi-elemental analysis capability without using standards. Additionally, the k0 method describes NAA in physically and mathematically understandable definitions and is very suitable for computer evaluation. Eventually, the k0-NAA method has been adopted by MINT in 2003, in collaboration with the Nuclear Research Institute (NRI), Vietnam. The reactor neutron parameters ( α and f) for the pneumatic transfer system and for the rotary rack at various locations, as well as the detector efficiencies were determined. After calibration of the reactor and the detectors, the implemented k0 method was validated by analyzing some certified reference materials (including IAEA Soil 7, NIST 1633a, NIST 1632c, NIST 1646a and IAEA 140/TM). The analysis results of the CRMs showed an average u score well below the threshold value of 2 with a precision of better than ±10% for most of the elemental concentrations obtained, validating herewith the introduction of the k0-NAA method at the MINT.
40 CFR 418.55 - Standards of performance for new sources.
Code of Federal Regulations, 2013 CFR
2013-07-01
... material ammonia is in the gaseous form: [Metric units, kg/kkg of product; English units, lb/1,000 lb of... consecutive days shall not exceed— Ammonia (as N) 0.0045 0.00045 Nitrate (as N) 0.17 0.023 (b) The following... from nitric acid production in which all the raw material ammonia is in the shipped liquid form...
Code of Federal Regulations, 2012 CFR
2012-07-01
... from nitric acid production in which all the raw material ammonia is in the gaseous form: [Metric units... limitations Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed— Ammonia... all the raw material ammonia is in the shipped liquid form: [Metric units, kg/kkg of product; English...
Code of Federal Regulations, 2011 CFR
2011-07-01
... from nitric acid production in which all the raw material ammonia is in the gaseous form: [Metric units... limitations Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed— Ammonia... all the raw material ammonia is in the shipped liquid form: [Metric units, kg/kkg of product; English...
40 CFR 418.55 - Standards of performance for new sources.
Code of Federal Regulations, 2010 CFR
2010-07-01
... material ammonia is in the gaseous form: [Metric units, kg/kkg of product; English units, lb/1,000 lb of... consecutive days shall not exceed— Ammonia (as N) 0.0045 0.00045 Nitrate (as N) 0.17 0.023 (b) The following... from nitric acid production in which all the raw material ammonia is in the shipped liquid form...
Code of Federal Regulations, 2014 CFR
2014-07-01
... from nitric acid production in which all the raw material ammonia is in the gaseous form: [Metric units... limitations Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed— Ammonia... all the raw material ammonia is in the shipped liquid form: [Metric units, kg/kkg of product; English...
Code of Federal Regulations, 2013 CFR
2013-07-01
... from nitric acid production in which all the raw material ammonia is in the gaseous form: [Metric units... limitations Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed— Ammonia... all the raw material ammonia is in the shipped liquid form: [Metric units, kg/kkg of product; English...
40 CFR 418.55 - Standards of performance for new sources.
Code of Federal Regulations, 2012 CFR
2012-07-01
... material ammonia is in the gaseous form: [Metric units, kg/kkg of product; English units, lb/1,000 lb of... consecutive days shall not exceed— Ammonia (as N) 0.0045 0.00045 Nitrate (as N) 0.17 0.023 (b) The following... from nitric acid production in which all the raw material ammonia is in the shipped liquid form...
Code of Federal Regulations, 2010 CFR
2010-07-01
... from nitric acid production in which all the raw material ammonia is in the gaseous form: [Metric units... limitations Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed— Ammonia... all the raw material ammonia is in the shipped liquid form: [Metric units, kg/kkg of product; English...
40 CFR 418.55 - Standards of performance for new sources.
Code of Federal Regulations, 2014 CFR
2014-07-01
... material ammonia is in the gaseous form: [Metric units, kg/kkg of product; English units, lb/1,000 lb of... consecutive days shall not exceed— Ammonia (as N) 0.0045 0.00045 Nitrate (as N) 0.17 0.023 (b) The following... from nitric acid production in which all the raw material ammonia is in the shipped liquid form...
40 CFR 418.55 - Standards of performance for new sources.
Code of Federal Regulations, 2011 CFR
2011-07-01
... material ammonia is in the gaseous form: [Metric units, kg/kkg of product; English units, lb/1,000 lb of... consecutive days shall not exceed— Ammonia (as N) 0.0045 0.00045 Nitrate (as N) 0.17 0.023 (b) The following... from nitric acid production in which all the raw material ammonia is in the shipped liquid form...
Lee, M H; Ahn, H J; Park, J H; Park, Y J; Song, K
2011-02-01
This paper presents a quantitative and rapid method of sequential separation of Pu, (90)Sr and (241)Am nuclides in environmental soil samples with an anion exchange resin and Sr Spec resin. After the sample solution was passed through an anion exchange column connected to a Sr Spec column, Pu isotopes were purified from the anion exchange column. Strontium-90 was separated from other interfering elements by the Sr Spec column. Americium-241 was purified from lanthanides by the anion exchange resin after oxalate co-precipitation. Measurement of Pu and Am isotopes was carried out using an α-spectrometer. Strontium-90 was measured by a low-level liquid scintillation counter. The radiochemical procedure of Pu, (90)Sr and (241)Am nuclides investigated in this study validated by application to IAEA reference materials and environmental soil samples. Copyright © 2010 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Badwan, Faris M.; Demuth, Scott Francis; Miller, Michael Conrad
Small Modular Reactors (SMR) with power levels significantly less than the currently standard 1000 to 1600-MWe reactors have been proposed as a potential game changer for future nuclear power. SMRs may offer a simpler, more standardized, and safer modular design by using factory built and easily transportable components. Additionally, SMRs may be more easily built and operated in isolated locations, and may require smaller initial capital investment and shorter construction times. Because many SMRs designs are still conceptual and consequently not yet fixed, designers have a unique opportunity to incorporate updated design basis threats, emergency preparedness requirements, and then fullymore » integrate safety, physical security, and safeguards/material control and accounting (MC&A) designs. Integrating safety, physical security, and safeguards is often referred to as integrating the 3Ss, and early consideration of safeguards and security in the design is often referred to as safeguards and security by design (SSBD). This paper describes U.S./Russian collaborative efforts toward developing an internationally accepted common approach for implementing SSBD/3Ss for SMRs based upon domestic requirements, and international guidance and requirements. These collaborative efforts originated with the Nuclear Energy and Nuclear Security working group established under the U.S.-Russia Bilateral Presidential Commission during the 2009 Presidential Summit. Initial efforts have focused on review of U.S. and Russian domestic requirements for Security and MC&A, IAEA guidance for security and MC&A, and IAEA requirements for international safeguards. Additionally, example SMR design features that can enhance proliferation resistance and physical security have been collected from past work and reported here. The development of a U.S./Russian common approach for SSBD/3Ss should aid the designer of SMRs located anywhere in the world. More specifically, the application of this approach may lead to more proliferation resistant and physically secure design features for SMRs.« less
Calculation of the nuclear material inventory in a sealed vault by 3D radiation mapping
DOE Office of Scientific and Technical Information (OSTI.GOV)
Adsley, Ian; Klepikov, Alexander; Tur, Yevgeniy
2013-07-01
The paper relates to the determination of the amount of nuclear material contained in a closed, concrete lined vault at the Aktau fast breeder reactor in Kazakhstan. This material had been disposed into the vault after examination in an experimental hot cell directly above the vault. In order to comply with IAEA Safeguards requirements it was necessary to determine the total quantities of nuclear materials - enriched uranium and plutonium - that were held with Kazakhstan. Although it was possible to determine the inventory of all of the accessible nuclear material - the quantity remaining in the vault was unknown.more » As part of the Global Threat Reduction Programme the UK Government funded a project to determine the inventory of these nuclear materials in this vault. This involved drilling three penetrations through the concrete lined roof of the vault; this enabled the placement of lights and a camera into the vault through two penetrations; while the third penetration enabled a lightweight manipulator arm to be introduced into the vault. This was used to provide a detailed 3D mapping of the dose rate within the vault and it also enabled the collection of samples for radionuclide analysis. The deconvolution of the 3D dose rate profile within the vault enabled the determination of the gamma emitting source distribution on the floor and walls of the vault. The samples were analysed to determine the fingerprint of those radionuclides producing the gamma dose - namely {sup 137}Cs and {sup 60}Co - to the nuclear materials. The combination of the dose rate source terms on the surfaces of the vault and the fingerprint then enabled the quantities of nuclear materials to be determined. The project was a major success and enabled the Kazakhstan Government to comply with IAEA Safeguards requirements. It also enabled the UK DECC Ministry to develop a technology of national (and international) use. Finally the technology was well received by IAEA Safeguards as an acceptable methodology for future studies. (authors)« less
Ultrasonic Fingerprinting of Structural Materials: Spent Nuclear Fuel Containers Case-Study
NASA Astrophysics Data System (ADS)
Sednev, D.; Lider, A.; Demyanuk, D.; Kroening, M.; Salchak, Y.
Nowadays, NDT is mainly focused on safety purposes, but it seems possible to apply those methods to provide national and IAEA safeguards. The containment of spent fuel in storage casks could be dramatically improved in case of development of so-called "smart" spent fuel storage and transfer casks. Such casks would have tamper indicating and monitoring/tracking features integrated directly into the cask design. The microstructure of the containers material as well as of the dedicated weld seam is applied to the lid and the cask body and provides a unique fingerprint of the full container, which can be reproducibly scanned by using an appropriate technique. The echo-sounder technique, which is the most commonly used method for material inspection, was chosen for this project. The main measuring parameter is acoustic noise, reflected from material's artefacts. The purpose is to obtain structural fingerprinting. Reference measurement and additional measurement results were compared. Obtained results have verified the appliance of structural fingerprint and the chosen control method. The successful authentication demonstrates the levels of the feature points' compliance exceeding the given threshold which differs considerably from the percentage of the concurrent points during authentication from other points. Since reproduction or doubling of the proposed unique identification characteristics is impossible at the current state science and technology, application of this technique is considered to identify the interference into the nuclear materials displacement with high accuracy.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Amount Determinations and the Administrative Review Process § 418.1305 What is not an initial... process as provided by §§ 418.1320 through 418.1325 and §§ 418.1340 through 418.1355, and they are not subject to judicial review. These actions include, but are not limited to, our dismissal of a request for...
Radiation processing of natural polymers: The IAEA contribution
NASA Astrophysics Data System (ADS)
Haji-Saeid, Mohammad; Safrany, Agnes; Sampa, Maria Helena de O.; Ramamoorthy, Natesan
2010-03-01
Radiation processing offers a clean and additive-free method for preparation of value-added novel materials based on renewable, non-toxic, and biodegradable natural polymers. Crosslinked natural polymers can be used as hydrogel wound dressings, face cleaning cosmetic masks, adsorbents of toxins, and non-bedsore mats; while low molecular weight products show antibiotic, antioxidant, and plant-growth promoting properties. Recognizing the potential benefits that radiation technology can offer for processing of natural polymers into useful products, the IAEA implemented a coordinated research project (CRP) on "Development of Radiation-processed products of Natural Polymers for application in Agriculture, Healthcare, Industry and Environment". This CRP was launched at the end of 2007 with participation of 16 MS to help connecting radiation technology and end-users to derive enhanced benefits from these new value-added products of radiation-processed natural materials. In this paper the results of activities in participating MS related to this work will be presented.
The Use of Performance Metrics for the Assessment of Safeguards Effectiveness at the State Level
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bachner K. M.; George Anzelon, Lawrence Livermore National Laboratory, Livermore, CA Yana Feldman, Lawrence Livermore National Laboratory, Livermore, CA Mark Goodman,Department of State, Washington, DC Dunbar Lockwood, National Nuclear Security Administration, Washington, DC Jonathan B. Sanborn, JBS Consulting, LLC, Arlington, VA.
In the ongoing evolution of International Atomic Energy Agency (IAEA) safeguards at the state level, many safeguards implementation principles have been emphasized: effectiveness, efficiency, non-discrimination, transparency, focus on sensitive materials, centrality of material accountancy for detecting diversion, independence, objectivity, and grounding in technical considerations, among others. These principles are subject to differing interpretations and prioritizations and sometimes conflict. This paper is an attempt to develop metrics and address some of the potential tradeoffs inherent in choices about how various safeguards policy principles are implemented. The paper carefully defines effective safeguards, including in the context of safeguards approaches that take accountmore » of the range of state-specific factors described by the IAEA Secretariat and taken note of by the Board in September 2014, and (2) makes use of performance metrics to help document, and to make transparent, how safeguards implementation would meet such effectiveness requirements.« less
NASA Astrophysics Data System (ADS)
Solodov, Alexander
The proliferation of nuclear weapons is a great threat to world peace and stability. The question of strengthening the nonproliferation regime has been open for a long period of time. In 1997 the International Atomic Energy Agency (IAEA) Board of Governors (BOG) adopted the Additional Safeguards Protocol. The purpose of the protocol is to enhance the IAEA's ability to detect undeclared production of fissile materials in member states. However, the IAEA does not always have sufficient human and financial resources to accomplish this task. Developed here is a concept for making use of human and technical resources available in academia that could be used to enhance the IAEA's mission. The objective of this research was to study the feasibility of an academic community using commercially or publicly available sources of information and products for the purpose of detecting covert facilities and activities intended for the unlawful acquisition of fissile materials or production of nuclear weapons. In this study, the availability and use of commercial satellite imagery systems, commercial computer codes for satellite imagery analysis, Comprehensive Test Ban Treaty (CTBT) verification International Monitoring System (IMS), publicly available information sources such as watchdog groups and press reports, and Customs Services information were explored. A system for integrating these data sources to form conclusions was also developed. The results proved that publicly and commercially available sources of information and data analysis can be a powerful tool in tracking violations in the international nuclear nonproliferation regime and a framework for implementing these tools in academic community was developed. As a result of this study a formation of an International Nonproliferation Monitoring Academic Community (INMAC) is proposed. This would be an independent organization consisting of academics (faculty, staff and students) from both nuclear weapon states (NWS) and non-nuclear weapon states (NNWS). This community analyzes all types of unclassified publicly and commercially available information to aid in detection of violations of the non-proliferation regime. INMAC shares all of this information with the IAEA and the public. Since INMAC is composed solely by members of the academic community, this organization would not demonstrate any biases in its investigations or reporting.
NASA Astrophysics Data System (ADS)
Kane, Steven Ze
A complete system has been simulated using experimentally obtained input parameters for the detection of special nuclear materials (SNM). A variation of the associated particle imaging (API) technique, referred to as reverse associated particle imaging detection (RAPID), has been developed in the context of detecting 5-kg spherical samples of U-235 in cargo containers uniformly filled with wood (low-Z) or iron (high-Z) at densities ranging from 0.1 g/cm3 to 0.4 g/cm3, the maximal density for a uniformly fully loaded 40-ft standard cargo container. In addition, samples were located at the center of a given container to study worst-case scenarios. The RAPID technique allows for the interrogation of containers at neutron production rates between 1x108 neutrons/s and 4x108 neutrons/s, depending on cargo material and density. These rates are low enough to prevent transmutation of materials in cargo and radiation safety hazards are limited. The merit of performance for the system is the time to detect the threat material with 95% probability of detection and 10-4 false positive rate per interrogated voxel of cargo. The detection of 5-kg of U-235 was chosen because this quantity of material is near the lower limit of the amount of special nuclear material that might be used in a nuclear weapon. This is in contrast to the 25-kg suggested sensitivity proposed by the International Atomic Energy Agency (IAEA).
Nichols, Alan L
2004-01-01
A Co-ordinated Research Project (CRP) was established in 1998 by the IAEA Nuclear Data Section (Update of X-ray and gamma-ray Decay Data Standards for Detector Calibration and Other Applications), in order to improve further the recommended decay data used to undertake efficiency calibrations of gamma-ray detectors. Participants in this CRP reviewed and modified the list of radionuclides most suited for detector efficiency calibration, and also considered the decay-data needs for safeguards, waste management, dosimetry, nuclear medicine, material analysis and environmental monitoring. Overall, 62 radionuclides were selected for decay-data evaluation, along with four parent-daughter combinations and two natural decay chains. gamma-ray emissions from specific nuclear reactions were also included to extend the calibrant energy well beyond 10 MeV. A significant number of these decay-data evaluations have been completed, and an IAEA-TECDOC report and database are in the process of being assembled for planned completion by the end of 2003.
Code of Federal Regulations, 2014 CFR
2014-07-01
... material ammonia is in the gaseous form: [Metric units, kg/kkg of product; English units, lb/1,000 lb of... consecutive days shall not exceed— Ammonia (as N) 0.0045 0.00045 Nitrate (as N) 0.17 0.023 (b) The following... from nitric acid production in which all the raw material ammonia is in the shipped liquid form...
Code of Federal Regulations, 2011 CFR
2011-07-01
... material ammonia is in the gaseous form: [Metric units, kg/kkg of product; English units, lb/1,000 lb of... consecutive days shall not exceed— Ammonia (as N) 0.0045 0.00045 Nitrate (as N) 0.17 0.023 (b) The following... from nitric acid production in which all the raw material ammonia is in the shipped liquid form...
Code of Federal Regulations, 2012 CFR
2012-07-01
... material ammonia is in the gaseous form: [Metric units, kg/kkg of product; English units, lb/1,000 lb of... consecutive days shall not exceed— Ammonia (as N) 0.0045 0.00045 Nitrate (as N) 0.17 0.023 (b) The following... from nitric acid production in which all the raw material ammonia is in the shipped liquid form...
Code of Federal Regulations, 2010 CFR
2010-07-01
... material ammonia is in the gaseous form: [Metric units, kg/kkg of product; English units, lb/1,000 lb of... consecutive days shall not exceed— Ammonia (as N) 0.0045 0.00045 Nitrate (as N) 0.17 0.023 (b) The following... from nitric acid production in which all the raw material ammonia is in the shipped liquid form...
Code of Federal Regulations, 2013 CFR
2013-07-01
... material ammonia is in the gaseous form: [Metric units, kg/kkg of product; English units, lb/1,000 lb of... consecutive days shall not exceed— Ammonia (as N) 0.0045 0.00045 Nitrate (as N) 0.17 0.023 (b) The following... from nitric acid production in which all the raw material ammonia is in the shipped liquid form...
43 CFR 418.29 - Project management.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 43 Public Lands: Interior 1 2010-10-01 2010-10-01 false Project management. 418.29 Section 418.29... INTERIOR OPERATING CRITERIA AND PROCEDURES FOR THE NEWLANDS RECLAMATION PROJECT, NEVADA Enforcement § 418.29 Project management. In addition to the provisions of § 418.28, if the District is found to be...
43 CFR 418.29 - Project management.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 43 Public Lands: Interior 1 2012-10-01 2011-10-01 true Project management. 418.29 Section 418.29... INTERIOR OPERATING CRITERIA AND PROCEDURES FOR THE NEWLANDS RECLAMATION PROJECT, NEVADA Enforcement § 418.29 Project management. In addition to the provisions of § 418.28, if the District is found to be...
43 CFR 418.29 - Project management.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 43 Public Lands: Interior 1 2014-10-01 2014-10-01 false Project management. 418.29 Section 418.29... INTERIOR OPERATING CRITERIA AND PROCEDURES FOR THE NEWLANDS RECLAMATION PROJECT, NEVADA Enforcement § 418.29 Project management. In addition to the provisions of § 418.28, if the District is found to be...
43 CFR 418.29 - Project management.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 43 Public Lands: Interior 1 2013-10-01 2013-10-01 false Project management. 418.29 Section 418.29... INTERIOR OPERATING CRITERIA AND PROCEDURES FOR THE NEWLANDS RECLAMATION PROJECT, NEVADA Enforcement § 418.29 Project management. In addition to the provisions of § 418.28, if the District is found to be...
Zinc-finger protein 418 overexpression protects against cardiac hypertrophy and fibrosis
Huang, Zirui; Zhu, Zhilin; Xu, Chunli; Teng, Lin; He, Ling; Gu, Chen; Yi, Cai
2017-01-01
Background This study aimed to investigated the effect and mechanism of zinc-finger protein 418 (ZNF418) on cardiac hypertrophy caused by aortic banding (AB), phenylephrine (PE) or angiotensin II (Ang II) in vivo and in vitro. Methods The expression of ZNF418 in hearts of patients with dilated cardiomyopathy (DCM) or hypertrophic cardiomyopathy (HCM) and AB-induced cardiac hypertrophy mice, as well as in Ang II- or PE-induced hypertrophic primary cardiomyocytes was detected by western blotting. Then, the expression of ZNF418 was up-regulated or down-regulated in AB-induced cardiac hypertrophy mice and Ang II -induced hypertrophic primary cardiomyocytes. The hypertrophic responses and fibrosis were evaluated by echocardiography and histological analysis. The mRNA levels of hypertrophy markers and fibrotic markers were detected by RT-qPCR. Furthermore, the phosphorylation and total levels of c-Jun were measured by western blotting. Results ZNF418 was markedly down-regulated in hearts of cardiac hypertrophy and hypertrophic primary cardiomyocytes. Down-regulated ZNF418 exacerbated the myocyte size and fibrosis, moreover increased the mRNA levels of ANP, BNP, β-MHC, MCIP1.4, collagen 1a, collagen III, MMP-2 and fibronection in hearts of AB-treated ZNF418 knockout mice or Ang II-treated cardiomyocytes with AdshZNF418. Conversely, these hypertrophic responses were reduced in the ZNF418 transgenic (TG) mice treated by AB and the AdZNF418-transfected primary cardiomyocytes treated by Ang II. Additionally, the deficiency of ZNF418 enhanced the phosphorylation level of c-jun, and overexpression of ZNF418 suppressed the phosphorylation level of c-jun in vivo and in vitro. Conclusion ZNF418 maybe attenuate hypertrophic responses by inhibiting the activity of c-jun/AP-1. PMID:29065170
42 CFR 418.205 - Special requirements for hospice pre-election evaluation and counseling services.
Code of Federal Regulations, 2013 CFR
2013-10-01
... evaluation and counseling services. 418.205 Section 418.205 Public Health CENTERS FOR MEDICARE & MEDICAID... Covered Services § 418.205 Special requirements for hospice pre-election evaluation and counseling... pre-election evaluation and counseling services as specified in § 418.304(d) may be made to a hospice...
42 CFR 418.205 - Special requirements for hospice pre-election evaluation and counseling services.
Code of Federal Regulations, 2012 CFR
2012-10-01
... evaluation and counseling services. 418.205 Section 418.205 Public Health CENTERS FOR MEDICARE & MEDICAID... Covered Services § 418.205 Special requirements for hospice pre-election evaluation and counseling... pre-election evaluation and counseling services as specified in § 418.304(d) may be made to a hospice...
42 CFR 418.205 - Special requirements for hospice pre-election evaluation and counseling services.
Code of Federal Regulations, 2014 CFR
2014-10-01
... evaluation and counseling services. 418.205 Section 418.205 Public Health CENTERS FOR MEDICARE & MEDICAID... Covered Services § 418.205 Special requirements for hospice pre-election evaluation and counseling... pre-election evaluation and counseling services as specified in § 418.304(d) may be made to a hospice...
Application of Nanoparticles/Nanowires and Carbon Nanotubes for Breast Cancer Research
2005-09-01
References ALI : Please (see Fig. 8A, the current decreased from 5.94 pA to 1.43 jA). I. Ruoff, R. S. and Lorents, D. C. (1995), Cat-bon 33, 925-930...51,418-427. names. received only the PBS solution. When near infrared light 7. Dubertret, S. B., Norris, D. J., Noireaux, V., Brivanlou , A. H., about 800
Taking Steps to Protect Against the Insider Threat
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pope, Noah Gale; Williams, Martha; Lewis, Joel
2015-10-16
Research reactors are required (in accordance with the Safeguards Agreement between the State and the IAEA) to maintain a system of nuclear material accounting and control for reporting quantities of nuclear material received, shipped, and held on inventory. Enhancements to the existing accounting and control system can be made at little additional cost to the facility, and these enhancements can make nuclear material accounting and control useful for nuclear security. In particular, nuclear material accounting and control measures can be useful in protecting against an insider who is intent on unauthorized removal or misuse of nuclear material or misuse ofmore » equipment. An enhanced nuclear material accounting and control system that responds to nuclear security is described in NSS-25G, Use of Nuclear Material Accounting and Control for Nuclear Security Purposes at Facilities, which is scheduled for distribution by the IAEA Department of Nuclear Security later this year. Accounting and control measures that respond to the insider threat are also described in NSS-33, Establishing a System for Control of Nuclear Material for Nuclear Security Purposes at a Facility During Storage, Use and Movement, and in NSS-41, Preventive and Protective Measures against Insider Threats (originally issued as NSS-08), which are available in draft form. This paper describes enhancements to existing material control and accounting systems that are specific to research reactors, and shows how they are important to nuclear security and protecting against an insider.« less
Project of electro-cyclotron resonance ion source test-bench for material investigation.
Kulevoy, T V; Chalykh, B B; Kuibeda, R P; Kropachev, G N; Ziiatdinova, A V
2014-02-01
Development of new materials for future energy facilities with higher operating efficiency is a challenging and crucial task. However, full-scale testing of radiation hardness for reactor materials is quite sophisticated and difficult as it requires long session of reactor irradiation; moreover, induced radioactivity considerably complicates further investigation. Ion beam irradiation does not have such a drawback; on the contrary, it has certain advantages. One of them is high speed of defect formation. Therefore, it provides a useful tool for modeling of different radiation damages. Improved understanding of material behavior under high dose irradiation will probably allow to simulate reactor irradiation close to real conditions and to make an adequate estimation of material radiation hardness. Since 2008 in Institute for Theoretical and Experimental Physics, the ion beam irradiation experiments are under development at the heavy ion radio frequency quadrupole linac and very important results are obtained already [T. V. Kulevoy et al., in Proceedings of the International Topical Meeting on Nuclear Research Applications and Utilization of Accelerators, IAEA Vienna, Austria, 2009, http://www.pub.iaea.org/MTCD/publications/PDF/P1433_CD/darasets/papers/ap_p5_07.pdf]. Nevertheless, the new test bench based on electro-cyclotron resonance ion source and high voltage platform is developed. The project of the test bench is presented and discussed.
Project of electro-cyclotron resonance ion source test-bench for material investigation
NASA Astrophysics Data System (ADS)
Kulevoy, T. V.; Chalykh, B. B.; Kuibeda, R. P.; Kropachev, G. N.; Ziiatdinova, A. V.
2014-02-01
Development of new materials for future energy facilities with higher operating efficiency is a challenging and crucial task. However, full-scale testing of radiation hardness for reactor materials is quite sophisticated and difficult as it requires long session of reactor irradiation; moreover, induced radioactivity considerably complicates further investigation. Ion beam irradiation does not have such a drawback; on the contrary, it has certain advantages. One of them is high speed of defect formation. Therefore, it provides a useful tool for modeling of different radiation damages. Improved understanding of material behavior under high dose irradiation will probably allow to simulate reactor irradiation close to real conditions and to make an adequate estimation of material radiation hardness. Since 2008 in Institute for Theoretical and Experimental Physics, the ion beam irradiation experiments are under development at the heavy ion radio frequency quadrupole linac and very important results are obtained already [T. V. Kulevoy et al., in Proceedings of the International Topical Meeting on Nuclear Research Applications and Utilization of Accelerators, IAEA Vienna, Austria, 2009, http://www.pub.iaea.org/MTCD/publications/PDF/P1433_CD/darasets/papers/ap_p5_07.pdf]. Nevertheless, the new test bench based on electro-cyclotron resonance ion source and high voltage platform is developed. The project of the test bench is presented and discussed.
Medical physics in Europe following recommendations of the International Atomic Energy Agency.
Casar, Bozidar; Lopes, Maria do Carmo; Drljević, Advan; Gershkevitsh, Eduard; Pesznyak, Csilla
2016-03-01
Medical physics is a health profession where principles of applied physics are mostly directed towards the application of ionizing radiation in medicine. The key role of the medical physics expert in safe and effective use of ionizing radiation in medicine was widely recognized in recent European reference documents like the European Union Council Directive 2013/59/EURATOM (2014), and European Commission Radiation Protection No. 174, European Guidelines on Medical Physics Expert (2014). Also the International Atomic Energy Agency (IAEA) has been outspoken in supporting and fostering the status of medical physics in radiation medicine through multiple initiatives as technical and cooperation projects and important documents like IAEA Human Health Series No. 25, Roles and Responsibilities, and Education and Training Requirements for Clinically Qualified Medical Physicists (2013) and the International Basic Safety Standards, General Safety Requirements Part 3 (2014). The significance of these documents and the recognition of the present insufficient fulfilment of the requirements and recommendations in many European countries have led the IAEA to organize in 2015 the Regional Meeting on Medical Physics in Europe, where major issues in medical physics in Europe were discussed. Most important outcomes of the meeting were the recommendations addressed to European member states and the survey on medical physics status in Europe conducted by the IAEA and European Federation of Organizations for Medical Physics. Published recommendations of IAEA Regional Meeting on Medical Physics in Europe shall be followed and enforced in all European states. Appropriate qualification framework including education, clinical specialization, certification and registration of medical physicists shall be established and international recommendation regarding staffing levels in the field of medical physics shall be fulfilled in particular. European states have clear legal and moral responsibility to effectively transpose Basic Safety Standards into national legislation in order to ensure high quality and safety in patient healthcare.
Medical physics in Europe following recommendations of the International Atomic Energy Agency
Lopes, Maria do Carmo; Drljević, Advan; Gershkevitsh, Eduard; Pesznyak, Csilla
2016-01-01
Background Medical physics is a health profession where principles of applied physics are mostly directed towards the application of ionizing radiation in medicine. The key role of the medical physics expert in safe and effective use of ionizing radiation in medicine was widely recognized in recent European reference documents like the European Union Council Directive 2013/59/EURATOM (2014), and European Commission Radiation Protection No. 174, European Guidelines on Medical Physics Expert (2014). Also the International Atomic Energy Agency (IAEA) has been outspoken in supporting and fostering the status of medical physics in radiation medicine through multiple initiatives as technical and cooperation projects and important documents like IAEA Human Health Series No. 25, Roles and Responsibilities, and Education and Training Requirements for Clinically Qualified Medical Physicists (2013) and the International Basic Safety Standards, General Safety Requirements Part 3 (2014). The significance of these documents and the recognition of the present insufficient fulfilment of the requirements and recommendations in many European countries have led the IAEA to organize in 2015 the Regional Meeting on Medical Physics in Europe, where major issues in medical physics in Europe were discussed. Most important outcomes of the meeting were the recommendations addressed to European member states and the survey on medical physics status in Europe conducted by the IAEA and European Federation of Organizations for Medical Physics. Conclusions Published recommendations of IAEA Regional Meeting on Medical Physics in Europe shall be followed and enforced in all European states. Appropriate qualification framework including education, clinical specialization, certification and registration of medical physicists shall be established and international recommendation regarding staffing levels in the field of medical physics shall be fulfilled in particular. European states have clear legal and moral responsibility to effectively transpose Basic Safety Standards into national legislation in order to ensure high quality and safety in patient healthcare. PMID:27069451
42 CFR 418.205 - Special requirements for hospice pre-election evaluation and counseling services.
Code of Federal Regulations, 2011 CFR
2011-10-01
... evaluation and counseling services. 418.205 Section 418.205 Public Health CENTERS FOR MEDICARE & MEDICAID... Services § 418.205 Special requirements for hospice pre-election evaluation and counseling services. (a... evaluation and counseling services as specified in § 418.304(d) may be made to a hospice on behalf of a...
42 CFR 418.205 - Special requirements for hospice pre-election evaluation and counseling services.
Code of Federal Regulations, 2010 CFR
2010-10-01
... evaluation and counseling services. 418.205 Section 418.205 Public Health CENTERS FOR MEDICARE & MEDICAID... Services § 418.205 Special requirements for hospice pre-election evaluation and counseling services. (a... evaluation and counseling services as specified in § 418.304(d) may be made to a hospice on behalf of a...
NASA Astrophysics Data System (ADS)
Infantino, Angelo; Marengo, Mario; Baschetti, Serafina; Cicoria, Gianfranco; Longo Vaschetto, Vittorio; Lucconi, Giulia; Massucci, Piera; Vichi, Sara; Zagni, Federico; Mostacci, Domiziano
2015-11-01
Biomedical cyclotrons for production of Positron Emission Tomography (PET) radionuclides and radiotherapy with hadrons or ions are widely diffused and established in hospitals as well as in industrial facilities and research sites. Guidelines for site planning and installation, as well as for radiation protection assessment, are given in a number of international documents; however, these well-established guides typically offer analytic methods of calculation of both shielding and materials activation, in approximate or idealized geometry set up. The availability of Monte Carlo codes with accurate and up-to-date libraries for transport and interactions of neutrons and charged particles at energies below 250 MeV, together with the continuously increasing power of nowadays computers, makes systematic use of simulations with realistic geometries possible, yielding equipment and site specific evaluation of the source terms, shielding requirements and all quantities relevant to radiation protection. In this work, the well-known Monte Carlo code FLUKA was used to simulate two representative models of cyclotron for PET radionuclides production, including their targetry; and one type of proton therapy cyclotron including the energy selection system. Simulations yield estimates of various quantities of radiological interest, including the effective dose distribution around the equipment, the effective number of neutron produced per incident proton and the activation of target materials, the structure of the cyclotron, the energy degrader, the vault walls and the soil. The model was validated against experimental measurements and comparison with well-established reference data. Neutron ambient dose equivalent H*(10) was measured around a GE PETtrace cyclotron: an average ratio between experimental measurement and simulations of 0.99±0.07 was found. Saturation yield of 18F, produced by the well-known 18O(p,n)18F reaction, was calculated and compared with the IAEA recommended value: a ratio simulation to IAEA of 1.01±0.10 was found.
Code of Federal Regulations, 2011 CFR
2011-04-01
... more recent tax year? 418.2201 Section 418.2201 Employees' Benefits SOCIAL SECURITY ADMINISTRATION... Determinations Using A More Recent Tax Year's Modified Adjusted Gross Income § 418.2201 When will we determine... that you provide for a more recent tax year? We will follow the rules in § 418.1201, except that any...
Code of Federal Regulations, 2012 CFR
2012-04-01
... more recent tax year? 418.1201 Section 418.1201 Employees' Benefits SOCIAL SECURITY ADMINISTRATION... Recent Tax Year's Modified Adjusted Gross Income § 418.1201 When will we determine your income-related... more recent tax year? We will use a more recent tax year than the years described in § 418.1135(a) or...
Code of Federal Regulations, 2012 CFR
2012-04-01
... more recent tax year? 418.2201 Section 418.2201 Employees' Benefits SOCIAL SECURITY ADMINISTRATION... Determinations Using A More Recent Tax Year's Modified Adjusted Gross Income § 418.2201 When will we determine... that you provide for a more recent tax year? We will follow the rules in § 418.1201, except that any...
Code of Federal Regulations, 2011 CFR
2011-04-01
... more recent tax year? 418.1201 Section 418.1201 Employees' Benefits SOCIAL SECURITY ADMINISTRATION... Recent Tax Year's Modified Adjusted Gross Income § 418.1201 When will we determine your income-related... more recent tax year? We will use a more recent tax year than the years described in § 418.1135(a) or...
Code of Federal Regulations, 2014 CFR
2014-04-01
... more recent tax year? 418.1201 Section 418.1201 Employees' Benefits SOCIAL SECURITY ADMINISTRATION... Recent Tax Year's Modified Adjusted Gross Income § 418.1201 When will we determine your income-related... more recent tax year? We will use a more recent tax year than the years described in § 418.1135(a) or...
Code of Federal Regulations, 2013 CFR
2013-04-01
... more recent tax year? 418.1201 Section 418.1201 Employees' Benefits SOCIAL SECURITY ADMINISTRATION... Recent Tax Year's Modified Adjusted Gross Income § 418.1201 When will we determine your income-related... more recent tax year? We will use a more recent tax year than the years described in § 418.1135(a) or...
Code of Federal Regulations, 2013 CFR
2013-04-01
... more recent tax year? 418.2201 Section 418.2201 Employees' Benefits SOCIAL SECURITY ADMINISTRATION... Determinations Using A More Recent Tax Year's Modified Adjusted Gross Income § 418.2201 When will we determine... that you provide for a more recent tax year? We will follow the rules in § 418.1201, except that any...
Code of Federal Regulations, 2010 CFR
2010-04-01
... more recent tax year? 418.1201 Section 418.1201 Employees' Benefits SOCIAL SECURITY ADMINISTRATION... Recent Tax Year's Modified Adjusted Gross Income § 418.1201 When will we determine your income-related... more recent tax year? We will use a more recent tax year than the years described in § 418.1135(a) or...
Code of Federal Regulations, 2014 CFR
2014-04-01
... more recent tax year? 418.2201 Section 418.2201 Employees' Benefits SOCIAL SECURITY ADMINISTRATION... Determinations Using A More Recent Tax Year's Modified Adjusted Gross Income § 418.2201 When will we determine... that you provide for a more recent tax year? We will follow the rules in § 418.1201, except that any...
Safeguards: The past present, and future
DOE Office of Scientific and Technical Information (OSTI.GOV)
Seaton, M.B.
1987-07-01
The non-destructive assay techniques developed at Los Alamos have become a primary means for verification by the IAEA and most important for domestic safeguards. We must challenge our assumptions, e.g., that inventory differences are a valid measure of safeguards performance, that more money is the solution, and the threats are much exaggerated. A human reliability program will be initiated. Material control, accounting, and physical protection need further integration. A serious effort involving scholarships, internships, etc. is needed to attract and motivate young people. Increased emphasis will be placed on designing safeguards into new systems such as laser isotope separation. Finally,more » continuing generous support for the IAEA is most important.« less
Palmans, Hugo; Nafaa, Laila; De, Jans Jo; Gillis, Sofie; Hoornaert, Marie-Thérèse; Martens, Chantal; Piessens, Marleen; Thierens, Hubert; Van der Plaetsen, Ann; Vynckier, Stefaan
2002-02-07
In recent years, a change has been proposed from air kerma based reference dosimetry to absorbed dose based reference dosimetry for all radiotherapy beams of ionizing radiation. In this paper, a dosimetry study is presented in which absorbed dose based dosimetry using recently developed formalisms was compared with air kerma based dosimetry using older formalisms. Three ionization chambers of each of three different types were calibrated in terms of absorbed dose to water and air kerma and sent to five hospitals. There, reference dosimetry with all the chambers was performed in a total of eight high-energy clinical photon beams. The selected chamber types were the NE2571, the PTW-30004 and the Wellhöfer-FC65G (previously Wellhöfer-IC70). Having a graphite wall, they exhibit a stable volume and the presence of an aluminium electrode ensures the robustness of these chambers. The data were analysed with the most important recommendations for clinical dosimetry: IAEA TRS-398, AAPM TG-51, IAEA TRS-277, NCS report-2 (presently recommended in Belgium) and AAPM TG-21. The necessary conversion factors were taken from those protocols, or calculated using the data in the different protocols if data for a chamber type are lacking. Polarity corrections were within 0.1% for all chambers in all beams. Recombination corrections were consistent with theoretical predictions, did not vary within a chamber type and only slightly between different chamber types. The maximum chamber-to-chamber variations of the dose obtained with the different formalisms within the same chamber type were between 0.2% and 0.6% for the NE2571, between 0.2% and 0.6% for the PTW-30004 and 0.1% and 0.3% for the Wellhöfer-FC65G for the different beams. The absorbed dose results for the NE2571 and Wellhöfer-FC65G chambers were in good agreement for all beams and all formalisms. The PTW-30004 chambers gave a small but systematically higher result compared to the result for the NE2571 chambers (on the average 0.1% for IAEA TRS-277, 0.3% for NCS report-2 and AAPM TG-21 and 0.4% for IAEA TRS-398 and AAPM TG-51). Within the air kerma based protocols, the results obtained with the TG-21 protocol were 0.4-0.8% higher mainly due to the differences in the data used. Both absorbed dose to water based formalisms resulted in consistent values within 0.3%. The change from old to new formalisms is discussed together with the traceability of calibration factors obtained at the primary absorbed dose and air kerma standards in the reference beams (60Co). For the particular situation in Belgium (calibrations at the Laboratory for Standard Dosimetry of Ghent) the change amounts to 0.1-0.6%. This is similar to the magnitude of the change determined in other countries.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 29 2014-07-01 2012-07-01 true [Reserved] 418.24 Section 418.24 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Ammonia Subcategory § 418.24 [Reserved] ...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 30 2012-07-01 2012-07-01 false [Reserved] 418.24 Section 418.24 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Ammonia Subcategory § 418.24 [Reserved] ...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 30 2013-07-01 2012-07-01 true [Reserved] 418.24 Section 418.24 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Ammonia Subcategory § 418.24 [Reserved] ...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 28 2010-07-01 2010-07-01 true [Reserved] 418.24 Section 418.24 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Ammonia Subcategory § 418.24 [Reserved] ...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 29 2011-07-01 2009-07-01 true [Reserved] 418.24 Section 418.24 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Ammonia Subcategory § 418.24 [Reserved] ...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 30 2012-07-01 2012-07-01 false [Reserved] 418.14 Section 418.14 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Phosphate Subcategory § 418.14 [Reserved] ...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 30 2013-07-01 2012-07-01 true [Reserved] 418.14 Section 418.14 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Phosphate Subcategory § 418.14 [Reserved] ...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 29 2014-07-01 2012-07-01 true [Reserved] 418.14 Section 418.14 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Phosphate Subcategory § 418.14 [Reserved] ...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 29 2014-07-01 2012-07-01 true [Reserved] 418.34 Section 418.34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Urea Subcategory § 418.34 [Reserved] ...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 30 2012-07-01 2012-07-01 false [Reserved] 418.34 Section 418.34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Urea Subcategory § 418.34 [Reserved] ...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 30 2013-07-01 2012-07-01 true [Reserved] 418.34 Section 418.34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Urea Subcategory § 418.34 [Reserved] ...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 29 2011-07-01 2009-07-01 true [Reserved] 418.34 Section 418.34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Urea Subcategory § 418.34 [Reserved] ...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 28 2010-07-01 2010-07-01 true [Reserved] 418.14 Section 418.14 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Phosphate Subcategory § 418.14 [Reserved] ...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 29 2011-07-01 2009-07-01 true [Reserved] 418.14 Section 418.14 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Phosphate Subcategory § 418.14 [Reserved] ...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 28 2010-07-01 2010-07-01 true [Reserved] 418.34 Section 418.34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Urea Subcategory § 418.34 [Reserved] ...
10 CFR 75.5 - Interpretations.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 2 2010-01-01 2010-01-01 false Interpretations. 75.5 Section 75.5 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA AGREEMENT General Provisions § 75.5 Interpretations. Except as authorized specifically by the Commission in writing, no...
10 CFR 75.5 - Interpretations.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 2 2011-01-01 2011-01-01 false Interpretations. 75.5 Section 75.5 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA AGREEMENT General Provisions § 75.5 Interpretations. Except as authorized specifically by the Commission in writing, no...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Raffo-Caiado, Ana Claudia; Begovich, John M; Ferrada, Juan J
This is the final report that closed a joint collaboration effort between DOE and the National Nuclear Energy Commission of Brazil (CNEN). In 2005, DOE and CNEN started a collaborative effort to evaluate measures that can strengthen the effectiveness of international safeguards at a natural uranium conversion plant (NUCP). The work was performed by DOE s Oak Ridge National Laboratory and CNEN. A generic model of a NUCP was developed and typical processing steps were defined. Advanced instrumentation and techniques for verification purposes were identified and investigated. The scope of the work was triggered by the International Atomic Energy Agencymore » s 2003 revised policy concerning the starting point of safeguards at uranium conversion facilities. Prior to this policy only the final products of the uranium conversion plant were considered to be of composition and purity suitable for use in the nuclear fuel cycle and therefore, subject to the IAEA safeguards control. DOE and CNEN have explored options for implementing the IAEA policy, although Brazil understands that the new policy established by the IAEA is beyond the framework of the Quadripartite Agreement of which it is one of the parties, together with Argentina, the Brazilian-Argentine Agency for Accounting and Control of Nuclear Materials (ABACC) and the IAEA. Two technical papers on this subject were published at the 2005 and 2008 INMM Annual Meetings.« less
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 29 2014-07-01 2012-07-01 true [Reserved] 418.64 Section 418.64 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Ammonium Sulfate Production Subcategory § 418.64 [Reserved] ...
Code of Federal Regulations, 2010 CFR
2010-01-01
... REGULATIONS (CONTINUED) HOUSING Self-Help Technical Assistance Grants § 1944.418 [Reserved] ... 7 Agriculture 13 2010-01-01 2009-01-01 true [Reserved] 1944.418 Section 1944.418 Agriculture Regulations of the Department of Agriculture (Continued) RURAL HOUSING SERVICE, RURAL BUSINESS-COOPERATIVE...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 30 2012-07-01 2012-07-01 false [Reserved] 418.64 Section 418.64 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Ammonium Sulfate Production Subcategory § 418.64 [Reserved] ...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 30 2013-07-01 2012-07-01 true [Reserved] 418.64 Section 418.64 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Ammonium Sulfate Production Subcategory § 418.64 [Reserved] ...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 29 2011-07-01 2009-07-01 true [Reserved] 418.64 Section 418.64 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Ammonium Sulfate Production Subcategory § 418.64 [Reserved] ...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 28 2010-07-01 2010-07-01 true [Reserved] 418.64 Section 418.64 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Ammonium Sulfate Production Subcategory § 418.64 [Reserved] ...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 29 2014-07-01 2012-07-01 true [Reserved] 418.54 Section 418.54 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Nitric Acid Subcategory § 418.54 [Reserved] ...
40 CFR 418.31 - Specialized definitions.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 30 2012-07-01 2012-07-01 false Specialized definitions. 418.31 Section 418.31 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Urea Subcategory § 418.31 Specialized...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 30 2012-07-01 2012-07-01 false [Reserved] 418.54 Section 418.54 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Nitric Acid Subcategory § 418.54 [Reserved] ...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 30 2013-07-01 2012-07-01 true [Reserved] 418.54 Section 418.54 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Nitric Acid Subcategory § 418.54 [Reserved] ...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 29 2011-07-01 2009-07-01 true [Reserved] 418.54 Section 418.54 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Nitric Acid Subcategory § 418.54 [Reserved] ...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 28 2010-07-01 2010-07-01 true [Reserved] 418.54 Section 418.54 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Nitric Acid Subcategory § 418.54 [Reserved] ...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 29 2011-07-01 2009-07-01 true [Reserved] 418.44 Section 418.44 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Ammonium Nitrate Subcategory § 418.44 [Reserved] ...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 29 2014-07-01 2012-07-01 true [Reserved] 418.44 Section 418.44 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Ammonium Nitrate Subcategory § 418.44 [Reserved] ...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 30 2013-07-01 2012-07-01 true [Reserved] 418.44 Section 418.44 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Ammonium Nitrate Subcategory § 418.44 [Reserved] ...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 30 2012-07-01 2012-07-01 false [Reserved] 418.44 Section 418.44 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Ammonium Nitrate Subcategory § 418.44 [Reserved] ...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 28 2010-07-01 2010-07-01 true [Reserved] 418.44 Section 418.44 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Ammonium Nitrate Subcategory § 418.44 [Reserved] ...
48 CFR 9904.418-50 - Techniques for application.
Code of Federal Regulations, 2010 CFR
2010-10-01
... objective's allocation base data shall be excluded from the base used to allocate the pool. (g) Use of... which the pool relates. (c) Change in allocation base. No change in an existing indirect cost pool allocation base is required if the allocation resulting from the existing base does not differ materially...
40 CFR 418.61 - Specialized definitions.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 29 2014-07-01 2012-07-01 true Specialized definitions. 418.61 Section 418.61 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Ammonium Sulfate Production Subcategory § 418.61...
40 CFR 418.61 - Specialized definitions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 30 2013-07-01 2012-07-01 true Specialized definitions. 418.61 Section 418.61 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Ammonium Sulfate Production Subcategory § 418.61...
40 CFR 418.61 - Specialized definitions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 28 2010-07-01 2010-07-01 true Specialized definitions. 418.61 Section 418.61 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Ammonium Sulfate Production Subcategory § 418.61...
40 CFR 418.61 - Specialized definitions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 29 2011-07-01 2009-07-01 true Specialized definitions. 418.61 Section 418.61 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Ammonium Sulfate Production Subcategory § 418.61...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 28 2010-07-01 2010-07-01 true [Reserved] 418.74 Section 418.74 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Mixed and Blend Fertilizer Production Subcategory § 418.74...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 30 2012-07-01 2012-07-01 false [Reserved] 418.74 Section 418.74 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Mixed and Blend Fertilizer Production Subcategory § 418.74...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 29 2011-07-01 2009-07-01 true [Reserved] 418.74 Section 418.74 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Mixed and Blend Fertilizer Production Subcategory § 418.74...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 29 2014-07-01 2012-07-01 true [Reserved] 418.74 Section 418.74 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Mixed and Blend Fertilizer Production Subcategory § 418.74...
40 CFR 418.31 - Specialized definitions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 30 2013-07-01 2012-07-01 true Specialized definitions. 418.31 Section 418.31 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Urea Subcategory § 418.31 Specialized definitions...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 30 2013-07-01 2012-07-01 true [Reserved] 418.74 Section 418.74 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Mixed and Blend Fertilizer Production Subcategory § 418.74...
40 CFR 418.31 - Specialized definitions.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 29 2014-07-01 2012-07-01 true Specialized definitions. 418.31 Section 418.31 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Urea Subcategory § 418.31 Specialized definitions...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 21 2011-07-01 2011-07-01 false Definitions. 98.418 Section 98.418 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Industrial Greenhouse Gases § 98.418 Definitions. Except as provided...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 22 2013-07-01 2013-07-01 false Definitions. 98.418 Section 98.418 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Industrial Greenhouse Gases § 98.418 Definitions. Except as provided...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 21 2014-07-01 2014-07-01 false Definitions. 98.418 Section 98.418 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Industrial Greenhouse Gases § 98.418 Definitions. Except as provided...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 22 2012-07-01 2012-07-01 false Definitions. 98.418 Section 98.418 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Industrial Greenhouse Gases § 98.418 Definitions. Except as provided...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sexton, L.
2012-06-06
Environmental sampling has become a key component of International Atomic Energy Agency (IAEA) safeguards approaches since its approval for use in 1996. Environmental sampling supports the IAEA's mission of drawing conclusions concerning the absence of undeclared nuclear material or nuclear activities in a Nation State. Swipe sampling is the most commonly used method for the collection of environmental samples from bulk handling facilities. However, augmenting swipe samples with an air monitoring system, which could continuously draw samples from the environment of bulk handling facilities, could improve the possibility of the detection of undeclared activities. Continuous sampling offers the opportunity tomore » collect airborne materials before they settle onto surfaces which can be decontaminated, taken into existing duct work, filtered by plant ventilation, or escape via alternate pathways (i.e. drains, doors). Researchers at the Savannah River National Laboratory and Oak Ridge National Laboratory have been working to further develop an aerosol collection technology that could be installed at IAEA safeguarded bulk handling facilities. The addition of this technology may reduce the number of IAEA inspector visits required to effectively collect samples. The principal sample collection device is a patented Aerosol Contaminant Extractor (ACE) which utilizes electrostatic precipitation principles to deposit particulates onto selected substrates. Recent work has focused on comparing traditional swipe sampling to samples collected via an ACE system, and incorporating tamper resistant and tamper indicating (TRI) technologies into the ACE system. Development of a TRI-ACE system would allow collection of samples at uranium/plutonium bulk handling facilities in a manner that ensures sample integrity and could be an important addition to the international nuclear safeguards inspector's toolkit. This work was supported by the Next Generation Safeguards Initiative (NGSI), Office of Nonproliferation and International Security (NIS), National Nuclear Security Administration (NNSA).« less
40 CFR 418.20 - Applicability; description of the ammonia subcategory.
Code of Federal Regulations, 2012 CFR
2012-07-01
... ammonia subcategory. 418.20 Section 418.20 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Ammonia Subcategory § 418.20 Applicability; description of the ammonia subcategory. The provisions of this subpart are...
40 CFR 418.20 - Applicability; description of the ammonia subcategory.
Code of Federal Regulations, 2013 CFR
2013-07-01
... ammonia subcategory. 418.20 Section 418.20 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Ammonia Subcategory § 418.20 Applicability; description of the ammonia subcategory. The provisions of this subpart are...
40 CFR 418.20 - Applicability; description of the ammonia subcategory.
Code of Federal Regulations, 2011 CFR
2011-07-01
... ammonia subcategory. 418.20 Section 418.20 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Ammonia Subcategory § 418.20 Applicability; description of the ammonia subcategory. The provisions of this subpart are...
40 CFR 418.20 - Applicability; description of the ammonia subcategory.
Code of Federal Regulations, 2014 CFR
2014-07-01
... ammonia subcategory. 418.20 Section 418.20 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Ammonia Subcategory § 418.20 Applicability; description of the ammonia subcategory. The provisions of this subpart are...
40 CFR 418.20 - Applicability; description of the ammonia subcategory.
Code of Federal Regulations, 2010 CFR
2010-07-01
... ammonia subcategory. 418.20 Section 418.20 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Ammonia Subcategory § 418.20 Applicability; description of the ammonia subcategory. The provisions of this subpart are...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Definitions. 98.418 Section 98.418 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Industrial Greenhouse Gases § 98.418 Definitions. All terms used in...
47 CFR 54.418 - Digital Television Transition Notices by Eligible Telecommunications Carriers.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 3 2010-10-01 2010-10-01 false Digital Television Transition Notices by Eligible Telecommunications Carriers. 54.418 Section 54.418 Telecommunication FEDERAL COMMUNICATIONS... Low-Income Consumers § 54.418 Digital Television Transition Notices by Eligible Telecommunications...
47 CFR 54.418 - Digital Television Transition Notices by Eligible Telecommunications Carriers.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 3 2011-10-01 2011-10-01 false Digital Television Transition Notices by Eligible Telecommunications Carriers. 54.418 Section 54.418 Telecommunication FEDERAL COMMUNICATIONS... Low-Income Consumers § 54.418 Digital Television Transition Notices by Eligible Telecommunications...
15 CFR 971.418 - Diligence requirements.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 15 Commerce and Foreign Trade 3 2010-01-01 2010-01-01 false Diligence requirements. 971.418 Section 971.418 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued...: Terms, Conditions and Restrictions Terms, Conditions and Restrictions § 971.418 Diligence requirements...
47 CFR 54.418 - Digital Television Transition Notices by Eligible Telecommunications Carriers.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 3 2014-10-01 2014-10-01 false Digital Television Transition Notices by Eligible Telecommunications Carriers. 54.418 Section 54.418 Telecommunication FEDERAL COMMUNICATIONS... Low-Income Consumers § 54.418 Digital Television Transition Notices by Eligible Telecommunications...
47 CFR 54.418 - Digital Television Transition Notices by Eligible Telecommunications Carriers.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 3 2013-10-01 2013-10-01 false Digital Television Transition Notices by Eligible Telecommunications Carriers. 54.418 Section 54.418 Telecommunication FEDERAL COMMUNICATIONS... Low-Income Consumers § 54.418 Digital Television Transition Notices by Eligible Telecommunications...
47 CFR 54.418 - Digital Television Transition Notices by Eligible Telecommunications Carriers.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 3 2012-10-01 2012-10-01 false Digital Television Transition Notices by Eligible Telecommunications Carriers. 54.418 Section 54.418 Telecommunication FEDERAL COMMUNICATIONS... Low-Income Consumers § 54.418 Digital Television Transition Notices by Eligible Telecommunications...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nekoogar, F; Dowla, F
An IAEA Technical Meeting on Techniques for IAEA Verification of Enrichment Activities identified 'smart tags' as a technology that should be assessed for tracking and locating UF6 cylinders. Although there is vast commercial industry working on RFID systems, the vulnerabilities of commercial products are only beginning to emerge. Most of the commercially off-the-shelf (COTS) RFID systems operate in very narrow frequency bands, making them vulnerable to detection, jamming and tampering and also presenting difficulties when used around metals (i.e. UF6 cylinders). Commercial passive RFID tags have short range, while active RFID tags that provide long ranges have limited lifetimes. Theremore » are also some concerns with the introduction of strong (narrowband) radio frequency signals around radioactive and nuclear materials. Considering the shortcomings of commercial RFID systems, in their current form, they do not offer a promising solution for continuous monitoring and tracking of UF6 cylinders. In this paper, we identify the key challenges faced by commercial RFID systems for monitoring UF6 cylinders, and introduce an ultra-wideband approach for tag/reader communications that addresses most of the identified challenges for IAEA safeguards applications.« less
10 CFR 75.9 - Information collection requirements: OMB approval.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 2 2010-01-01 2010-01-01 false Information collection requirements: OMB approval. 75.9 Section 75.9 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA AGREEMENT General Provisions § 75.9 Information collection requirements: OMB approval...
10 CFR 75.11 - Location information.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 2 2011-01-01 2011-01-01 false Location information. 75.11 Section 75.11 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA AGREEMENT Facility and Location Information § 75.11 Location information. (a) As required by the Additional Protocol...
10 CFR 75.9 - Information collection requirements: OMB approval.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 2 2011-01-01 2011-01-01 false Information collection requirements: OMB approval. 75.9 Section 75.9 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA AGREEMENT General Provisions § 75.9 Information collection requirements: OMB approval...
Global threat reduction initiative Russian nuclear material removal progress
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cummins, Kelly; Bolshinsky, Igor
2008-07-15
In December 1999 representatives from the United States, the Russian Federation, and the International Atomic Energy Agency (IAEA) started discussing a program to return to Russia Soviet- or Russian-supplied highly enriched uranium (HEU) fuel stored at the Russian-designed research reactors outside Russia. Trilateral discussions among the United States, Russian Federation, and the International Atomic Energy Agency (IAEA) have identified more than 20 research reactors in 17 countries that have Soviet- or Russian-supplied HEU fuel. The Global Threat Reduction Initiative's Russian Research Reactor Fuel Return Program is an important aspect of the U.S. Government's commitment to cooperate with the other nationsmore » to prevent the proliferation of nuclear weapons and weapons-usable proliferation-attractive nuclear materials. To date, 496 kilograms of Russian-origin HEU have been shipped to Russia from Serbia, Latvia, Libya, Uzbekistan, Romania, Bulgaria, Poland, Germany, and the Czech Republic. The pilot spent fuel shipment from Uzbekistan to Russia was completed in April 2006. (author)« less
40 CFR 418.60 - Applicability; description of the ammonium sulfate production subcategory.
Code of Federal Regulations, 2012 CFR
2012-07-01
... ammonium sulfate production subcategory. 418.60 Section 418.60 Protection of Environment ENVIRONMENTAL... CATEGORY Ammonium Sulfate Production Subcategory § 418.60 Applicability; description of the ammonium sulfate production subcategory. The provisions of this subpart apply to discharges resulting from the...
40 CFR 418.60 - Applicability; description of the ammonium sulfate production subcategory.
Code of Federal Regulations, 2013 CFR
2013-07-01
... ammonium sulfate production subcategory. 418.60 Section 418.60 Protection of Environment ENVIRONMENTAL... CATEGORY Ammonium Sulfate Production Subcategory § 418.60 Applicability; description of the ammonium sulfate production subcategory. The provisions of this subpart apply to discharges resulting from the...
40 CFR 418.60 - Applicability; description of the ammonium sulfate production subcategory.
Code of Federal Regulations, 2014 CFR
2014-07-01
... ammonium sulfate production subcategory. 418.60 Section 418.60 Protection of Environment ENVIRONMENTAL... CATEGORY Ammonium Sulfate Production Subcategory § 418.60 Applicability; description of the ammonium sulfate production subcategory. The provisions of this subpart apply to discharges resulting from the...
40 CFR 418.60 - Applicability; description of the ammonium sulfate production subcategory.
Code of Federal Regulations, 2011 CFR
2011-07-01
... ammonium sulfate production subcategory. 418.60 Section 418.60 Protection of Environment ENVIRONMENTAL... CATEGORY Ammonium Sulfate Production Subcategory § 418.60 Applicability; description of the ammonium sulfate production subcategory. The provisions of this subpart apply to discharges resulting from the...
40 CFR 418.36 - Pretreatment standards for new sources.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 30 2013-07-01 2012-07-01 true Pretreatment standards for new sources. 418.36 Section 418.36 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Urea Subcategory § 418.36...
40 CFR 418.36 - Pretreatment standards for new sources.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 30 2012-07-01 2012-07-01 false Pretreatment standards for new sources. 418.36 Section 418.36 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Urea Subcategory § 418.36...
40 CFR 418.36 - Pretreatment standards for new sources.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 29 2014-07-01 2012-07-01 true Pretreatment standards for new sources. 418.36 Section 418.36 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Urea Subcategory § 418.36...
40 CFR 418.16 - Pretreatment standards for new sources.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 30 2012-07-01 2012-07-01 false Pretreatment standards for new sources. 418.16 Section 418.16 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Phosphate Subcategory § 418.16...
40 CFR 418.16 - Pretreatment standards for new sources.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 30 2013-07-01 2012-07-01 true Pretreatment standards for new sources. 418.16 Section 418.16 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Phosphate Subcategory § 418.16...
40 CFR 418.16 - Pretreatment standards for new sources.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 29 2014-07-01 2012-07-01 true Pretreatment standards for new sources. 418.16 Section 418.16 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Phosphate Subcategory § 418.16...
29 CFR 1926.418-1926.430 - [Reserved
Code of Federal Regulations, 2010 CFR
2010-07-01
... 29 Labor 8 2010-07-01 2010-07-01 false [Reserved] 1926.418-1926.430 Section 1926.418-1926.430 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION... Practices §§ 1926.418-1926.430 [Reserved] Safety-Related Maintenance and Environmental Considerations ...
40 CFR 418.36 - Pretreatment standards for new sources.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 29 2011-07-01 2009-07-01 true Pretreatment standards for new sources. 418.36 Section 418.36 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Urea Subcategory § 418.36...
40 CFR 418.16 - Pretreatment standards for new sources.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 28 2010-07-01 2010-07-01 true Pretreatment standards for new sources. 418.16 Section 418.16 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Phosphate Subcategory § 418.16...
40 CFR 418.16 - Pretreatment standards for new sources.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 29 2011-07-01 2009-07-01 true Pretreatment standards for new sources. 418.16 Section 418.16 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Phosphate Subcategory § 418.16...
48 CFR 9904.418-30 - Definitions.
Code of Federal Regulations, 2010 CFR
2010-10-01
... STANDARDS COST ACCOUNTING STANDARDS 9904.418-30 Definitions. (a) The following are definitions of terms... 48 Federal Acquisition Regulations System 7 2010-10-01 2010-10-01 false Definitions. 9904.418-30 Section 9904.418-30 Federal Acquisition Regulations System COST ACCOUNTING STANDARDS BOARD, OFFICE OF...
40 CFR 418.40 - Applicability; description of the ammonium nitrate subcategory.
Code of Federal Regulations, 2012 CFR
2012-07-01
... ammonium nitrate subcategory. 418.40 Section 418.40 Protection of Environment ENVIRONMENTAL PROTECTION... Ammonium Nitrate Subcategory § 418.40 Applicability; description of the ammonium nitrate subcategory. The provisions of this subpart are applicable to discharges resulting from the manufacture of ammonium nitrate...
40 CFR 418.40 - Applicability; description of the ammonium nitrate subcategory.
Code of Federal Regulations, 2011 CFR
2011-07-01
... ammonium nitrate subcategory. 418.40 Section 418.40 Protection of Environment ENVIRONMENTAL PROTECTION... Ammonium Nitrate Subcategory § 418.40 Applicability; description of the ammonium nitrate subcategory. The provisions of this subpart are applicable to discharges resulting from the manufacture of ammonium nitrate...
40 CFR 418.40 - Applicability; description of the ammonium nitrate subcategory.
Code of Federal Regulations, 2013 CFR
2013-07-01
... ammonium nitrate subcategory. 418.40 Section 418.40 Protection of Environment ENVIRONMENTAL PROTECTION... Ammonium Nitrate Subcategory § 418.40 Applicability; description of the ammonium nitrate subcategory. The provisions of this subpart are applicable to discharges resulting from the manufacture of ammonium nitrate...
40 CFR 418.40 - Applicability; description of the ammonium nitrate subcategory.
Code of Federal Regulations, 2014 CFR
2014-07-01
... ammonium nitrate subcategory. 418.40 Section 418.40 Protection of Environment ENVIRONMENTAL PROTECTION... Ammonium Nitrate Subcategory § 418.40 Applicability; description of the ammonium nitrate subcategory. The provisions of this subpart are applicable to discharges resulting from the manufacture of ammonium nitrate...
7 CFR 58.418 - Automatic cheese making equipment.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 3 2011-01-01 2011-01-01 false Automatic cheese making equipment. 58.418 Section 58.418 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING... Service 1 Equipment and Utensils § 58.418 Automatic cheese making equipment. (a) Automatic Curd Maker. The...
7 CFR 58.418 - Automatic cheese making equipment.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 3 2010-01-01 2010-01-01 false Automatic cheese making equipment. 58.418 Section 58.418 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING... Service 1 Equipment and Utensils § 58.418 Automatic cheese making equipment. (a) Automatic Curd Maker. The...
48 CFR 9904.418-63 - Effective date.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 7 2010-10-01 2010-10-01 false Effective date. 9904.418-63 Section 9904.418-63 Federal Acquisition Regulations System COST ACCOUNTING STANDARDS BOARD, OFFICE... ACCOUNTING STANDARDS COST ACCOUNTING STANDARDS 9904.418-63 Effective date. This Standard is effective as of...
42 CFR 418.104 - Condition of participation: Clinical records.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 42 Public Health 3 2013-10-01 2013-10-01 false Condition of participation: Clinical records. 418.104 Section 418.104 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND...: Organizational Environment § 418.104 Condition of participation: Clinical records. A clinical record containing...
42 CFR 418.104 - Condition of participation: Clinical records.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 42 Public Health 3 2012-10-01 2012-10-01 false Condition of participation: Clinical records. 418.104 Section 418.104 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND...: Organizational Environment § 418.104 Condition of participation: Clinical records. A clinical record containing...
42 CFR 418.104 - Condition of participation: Clinical records.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 42 Public Health 3 2014-10-01 2014-10-01 false Condition of participation: Clinical records. 418.104 Section 418.104 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND...: Organizational Environment § 418.104 Condition of participation: Clinical records. A clinical record containing...
37 CFR 41.8 - Mandatory notices.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 37 Patents, Trademarks, and Copyrights 1 2013-07-01 2013-07-01 false Mandatory notices. 41.8 Section 41.8 Patents, Trademarks, and Copyrights UNITED STATES PATENT AND TRADEMARK OFFICE, DEPARTMENT OF COMMERCE PRACTICE BEFORE THE PATENT TRIAL AND APPEAL BOARD General Provisions § 41.8 Mandatory notices. (a...
Strengthening IAEA Safeguards for Research Reactors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reid, Bruce D.; Anzelon, George A.; Budlong-Sylvester, Kory
During their December 10-11, 2013, workshop in Grenoble France, which focused on the history and future of safeguarding research reactors, the United States, France and the United Kingdom (UK) agreed to conduct a joint study exploring ways to strengthen the IAEA’s safeguards approach for declared research reactors. This decision was prompted by concerns about: 1) historical cases of non-compliance involving misuse (including the use of non-nuclear materials for production of neutron generators for weapons) and diversion that were discovered, in many cases, long after the violations took place and as part of broader pattern of undeclared activities in half amore » dozen countries; 2) the fact that, under the Safeguards Criteria, the IAEA inspects some reactors (e.g., those with power levels under 25 MWt) less than once per year; 3) the long-standing precedent of States using heavy water research reactors (HWRR) to produce plutonium for weapons programs; 4) the use of HEU fuel in some research reactors; and 5) various technical characteristics common to some types of research reactors that could provide an opportunity for potential proliferators to misuse the facility or divert material with low probability of detection by the IAEA. In some research reactors it is difficult to detect diversion or undeclared irradiation. In addition, infrastructure associated with research reactors could pose a safeguards challenge. To strengthen the effectiveness of safeguards at the State level, this paper advocates that the IAEA consider ways to focus additional attention and broaden its safeguards toolbox for research reactors. This increase in focus on the research reactors could begin with the recognition that the research reactor (of any size) could be a common path element on a large number of technically plausible pathways that must be considered when performing acquisition pathway analysis (APA) for developing a State Level Approach (SLA) and Annual Implementation Plan (AIP). To broaden the IAEA safeguards toolbox, the study recommends that the Agency consider closing potential gaps in safeguards coverage by, among other things: 1) adapting its safeguards measures based on a case-by-case assessment; 2) using more frequent and expanded/enhanced mailbox declarations (ideally with remote transmission of the data to IAEA Headquarters in Vienna) coupled with short-notice or unannounced inspections; 3) putting more emphasis on the collection and analysis of environmental samples at hot cells and waste storage tanks; 4) taking Safeguards by Design into account for the construction of new research reactors and best practices for existing research reactors; 5) utilizing fully all legal authorities to enhance inspection access (including a strengthened and continuing DIV process); and 6) utilizing new approaches to improve auditing activities, verify reactor operating data history, and track/monitor the movement and storage of spent fuel.« less
20 CFR 418.3220 - When is your application considered filed?
Code of Federal Regulations, 2010 CFR
2010-04-01
...? 418.3220 Section 418.3220 Employees' Benefits SOCIAL SECURITY ADMINISTRATION MEDICARE SUBSIDIES... the day it is submitted electronically through our Internet Web site. If a State Medicaid agency... subsidy application from our Internet Web site where the requirements set forth in § 418.3230 are met. ...
20 CFR 418.3220 - When is your application considered filed?
Code of Federal Regulations, 2011 CFR
2011-04-01
...? 418.3220 Section 418.3220 Employees' Benefits SOCIAL SECURITY ADMINISTRATION MEDICARE SUBSIDIES... the day it is submitted electronically through our Internet Web site. If a State Medicaid agency... subsidy application from our Internet Web site where the requirements set forth in § 418.3230 are met. ...
43 CFR 418.26 - Charges for water use.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 43 Public Lands: Interior 1 2011-10-01 2011-10-01 false Charges for water use. 418.26 Section 418... and Management § 418.26 Charges for water use. The District must maintain a financing and accounting... provides reasonable financial incentives for the economical and efficient use of water. ...
43 CFR 418.26 - Charges for water use.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 43 Public Lands: Interior 1 2010-10-01 2010-10-01 false Charges for water use. 418.26 Section 418... and Management § 418.26 Charges for water use. The District must maintain a financing and accounting... provides reasonable financial incentives for the economical and efficient use of water. ...
40 CFR 418.70 - Applicability; description of the mixed and blend fertilizer production subcategory.
Code of Federal Regulations, 2012 CFR
2012-07-01
... mixed and blend fertilizer production subcategory. 418.70 Section 418.70 Protection of Environment... SOURCE CATEGORY Mixed and Blend Fertilizer Production Subcategory § 418.70 Applicability; description of the mixed and blend fertilizer production subcategory. The provisions of this subpart are applicable...
43 CFR 418.6 - Fallon Paiute-Shoshone Indian Reservation.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 43 Public Lands: Interior 1 2013-10-01 2013-10-01 false Fallon Paiute-Shoshone Indian Reservation. 418.6 Section 418.6 Public Lands: Interior Regulations Relating to Public Lands BUREAU OF RECLAMATION... General Provisions § 418.6 Fallon Paiute-Shoshone Indian Reservation. Nothing in this part affects: (a...
43 CFR 418.6 - Fallon Paiute-Shoshone Indian Reservation.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 43 Public Lands: Interior 1 2011-10-01 2011-10-01 false Fallon Paiute-Shoshone Indian Reservation. 418.6 Section 418.6 Public Lands: Interior Regulations Relating to Public Lands BUREAU OF RECLAMATION... General Provisions § 418.6 Fallon Paiute-Shoshone Indian Reservation. Nothing in this part affects: (a...
43 CFR 418.6 - Fallon Paiute-Shoshone Indian Reservation.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 43 Public Lands: Interior 1 2010-10-01 2010-10-01 false Fallon Paiute-Shoshone Indian Reservation. 418.6 Section 418.6 Public Lands: Interior Regulations Relating to Public Lands BUREAU OF RECLAMATION... General Provisions § 418.6 Fallon Paiute-Shoshone Indian Reservation. Nothing in this part affects: (a...
43 CFR 418.26 - Charges for water use.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 43 Public Lands: Interior 1 2012-10-01 2011-10-01 true Charges for water use. 418.26 Section 418... and Management § 418.26 Charges for water use. The District must maintain a financing and accounting... provides reasonable financial incentives for the economical and efficient use of water. ...
43 CFR 418.26 - Charges for water use.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 43 Public Lands: Interior 1 2013-10-01 2013-10-01 false Charges for water use. 418.26 Section 418... and Management § 418.26 Charges for water use. The District must maintain a financing and accounting... provides reasonable financial incentives for the economical and efficient use of water. ...
42 CFR 418.102 - Condition of participation: Medical director.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 42 Public Health 3 2012-10-01 2012-10-01 false Condition of participation: Medical director. 418.102 Section 418.102 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND...: Organizational Environment § 418.102 Condition of participation: Medical director. The hospice must designate a...
42 CFR 418.102 - Condition of participation: Medical director.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 42 Public Health 3 2013-10-01 2013-10-01 false Condition of participation: Medical director. 418.102 Section 418.102 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND...: Organizational Environment § 418.102 Condition of participation: Medical director. The hospice must designate a...
42 CFR 418.102 - Condition of participation: Medical director.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 42 Public Health 3 2014-10-01 2014-10-01 false Condition of participation: Medical director. 418.102 Section 418.102 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND...: Organizational Environment § 418.102 Condition of participation: Medical director. The hospice must designate a...
43 CFR 418.20 - Diversions from the Truckee River to Lahontan Reservoir, January through June.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Lahontan Reservoir, January through June. 418.20 Section 418.20 Public Lands: Interior Regulations Relating... FOR THE NEWLANDS RECLAMATION PROJECT, NEVADA Operations and Management § 418.20 Diversions from the Truckee River to Lahontan Reservoir, January through June. (a) Truckee River diversions through the...
43 CFR 418.21 - Diversion of Truckee River water to Lahontan Reservoir, July through December.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Lahontan Reservoir, July through December. 418.21 Section 418.21 Public Lands: Interior Regulations... PROCEDURES FOR THE NEWLANDS RECLAMATION PROJECT, NEVADA Operations and Management § 418.21 Diversion of Truckee River water to Lahontan Reservoir, July through December. Truckee River diversions through the...
43 CFR 418.24 - Precautionary drawdown and spills from Lahontan Reservoir.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Lahontan Reservoir. 418.24 Section 418.24 Public Lands: Interior Regulations Relating to Public Lands... RECLAMATION PROJECT, NEVADA Operations and Management § 418.24 Precautionary drawdown and spills from Lahontan Reservoir. (a) Even though flood control is not a specifically authorized purpose of the Project, at the...
43 CFR 418.21 - Diversion of Truckee River water to Lahontan Reservoir, July through December.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Lahontan Reservoir, July through December. 418.21 Section 418.21 Public Lands: Interior Regulations... PROCEDURES FOR THE NEWLANDS RECLAMATION PROJECT, NEVADA Operations and Management § 418.21 Diversion of Truckee River water to Lahontan Reservoir, July through December. Truckee River diversions through the...
43 CFR 418.20 - Diversions from the Truckee River to Lahontan Reservoir, January through June.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Lahontan Reservoir, January through June. 418.20 Section 418.20 Public Lands: Interior Regulations Relating... FOR THE NEWLANDS RECLAMATION PROJECT, NEVADA Operations and Management § 418.20 Diversions from the Truckee River to Lahontan Reservoir, January through June. (a) Truckee River diversions through the...
43 CFR 418.24 - Precautionary drawdown and spills from Lahontan Reservoir.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Lahontan Reservoir. 418.24 Section 418.24 Public Lands: Interior Regulations Relating to Public Lands... RECLAMATION PROJECT, NEVADA Operations and Management § 418.24 Precautionary drawdown and spills from Lahontan Reservoir. (a) Even though flood control is not a specifically authorized purpose of the Project, at the...
20 CFR 418.2105 - What is the threshold?
Code of Federal Regulations, 2014 CFR
2014-04-01
... 20 Employees' Benefits 2 2014-04-01 2014-04-01 false What is the threshold? 418.2105 Section 418.2105 Employees' Benefits SOCIAL SECURITY ADMINISTRATION MEDICARE SUBSIDIES Income-Related Monthly Adjustments to Medicare Prescription Drug Coverage Premiums Determination of the Income-Related Monthly Adjustment Amount § 418.2105 What is the...
20 CFR 418.2105 - What is the threshold?
Code of Federal Regulations, 2011 CFR
2011-04-01
... 20 Employees' Benefits 2 2011-04-01 2011-04-01 false What is the threshold? 418.2105 Section 418.2105 Employees' Benefits SOCIAL SECURITY ADMINISTRATION MEDICARE SUBSIDIES Income-Related Monthly Adjustments to Medicare Prescription Drug Coverage Premiums Determination of the Income-Related Monthly Adjustment Amount § 418.2105 What is the...
20 CFR 418.2105 - What is the threshold?
Code of Federal Regulations, 2013 CFR
2013-04-01
... 20 Employees' Benefits 2 2013-04-01 2013-04-01 false What is the threshold? 418.2105 Section 418.2105 Employees' Benefits SOCIAL SECURITY ADMINISTRATION MEDICARE SUBSIDIES Income-Related Monthly Adjustments to Medicare Prescription Drug Coverage Premiums Determination of the Income-Related Monthly Adjustment Amount § 418.2105 What is the...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 2 2010-01-01 2010-01-01 false Exemptions. 75.3 Section 75.3 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA AGREEMENT General Provisions § 75.3 Exemptions. (a) The Commission may, upon application of any interested person or upon its own...
10 CFR 75.32 - Initial inventory report.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 2 2011-01-01 2011-01-01 false Initial inventory report. 75.32 Section 75.32 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA AGREEMENT Reports § 75.32 Initial inventory report. (a) The initial inventory reporting date shall be the...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 2 2011-01-01 2011-01-01 false Exemptions. 75.3 Section 75.3 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA AGREEMENT General Provisions § 75.3 Exemptions. (a) The Commission may, upon application of any interested person or upon its own...
Quality control assurance of strontium-90 in foodstuffs by LSC.
Lopes, I; Mourato, A; Abrantes, J; Carvalhal, G; Madruga, M J; Reis, M
2014-11-01
A method based on the separation of Sr-90 by extraction chromatography and beta determination by Liquid Scintillation Counting (LSC) technique was used for strontium analysis in food samples. The methodology consisted in prior sample treatment (drying and incineration) followed by radiochemical separation of Sr-90 by extraction chromatography, using the Sr-resin. The chemical yield was determined by gravimetric method, adding stable strontium to the matrix. Beta activity (Sr-90/Y-90) was determined using a low background liquid scintillation spectrometer (Tri-Carb 3170 TR/SL, Packard). The accuracy and the precision of the method, was performed previously through recovery trials with Sr-90 spiked samples, using the same type of matrices (milk, complete meals, meat and vegetables). A reference material (IAEA_321) was now used to measure the accuracy of the procedure. Participation in interlaboratory comparison exercises was also performed in order to establish an external control on the measurements and to ensure the adequacy of the method. Copyright © 2014 Elsevier Ltd. All rights reserved.
Wadhwa, Sham Kumar; Tuzen, Mustafa; Kazi, Tasneem Gul; Soylak, Mustafa; Hazer, Baki
2014-01-01
A new adsorbent, polyhydroxybutyrate-b-polyethyleneglycol, was used for the separation and preconcentration of copper(II) and lead(II) ions prior to their flame atomic absorption spectrometric detections. The influences of parameters such as pH, amount of adsorbent, flow rates and sample volumes were investigated. The polymer does not interact with alkaline, alkaline-earth metals and transition metals. The enrichment factor was 50. The detection limits were 0.32 μg L(-1) and 1.82 μg L(-1) for copper and lead, respectively. The recovery values were found >95%. The relative standard deviations were found to be less than 6%. The validation of the procedure was performed by analysing certified reference materials; NIST SRM 1515 Apple leaves, IAEA-336 Lichen and GBW-07605 Tea. The method was successfully applied for the analysis of analytes in water and food samples. Copyright © 2013 Elsevier Ltd. All rights reserved.
78 FR 40829 - Proposed Collection; Comment Request for Form 720-CS
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-08
...: Representatives of the motor fuel industry, state governments, and the Federal government are working to ensure...,900. Estimated Time per Respondent: 5 hours, 15 minutes. Estimated Total Annual Burden Hours: 209,418... relating to a collection of information must be retained as long as their contents may become material in...
NASA Technical Reports Server (NTRS)
Garland, J. L.; Cook, K. L.; Johnson, M.; Sumner, R.; Fields, N.; Sager, J. C. (Principal Investigator)
1997-01-01
A study evaluating alternative methods for long term operation of biomass production systems was recently completed at the Kennedy Space Center (KSC). The 418-day study evaluated repeated batch versus mixed-aged production of potato grown on either standard 1/2-strength Hoagland's nutrient solution or solutions including nutrients recycled from inedible plant material. The long term effects of closure and recycling on microbial dynamics were evaluated by monitoring the microbial communities associated with various habitats within the plant growth system (i.e., plant roots, nutrient solution, biofilms within the hydroponic systems, atmosphere, and atmospheric condensate). Plate count methods were used to enumerate and characterize microorganisms. Microscopic staining methods were used to estunate total cell densities. The primary finding was that the density and composition of microbial communities associated with controlled environmental plant growth systems are stable during long term operation. Continuous production resulted in slightly greater stability. Nutrient recycling, despite the addition of soluble organic material from the waste processing system, did not significantly increase microbial density in any of the habitats.
NASA Astrophysics Data System (ADS)
Garland, J. L.; Cook, K. L.; Johnson, M.; Sumner, R.; Fields, N.
1997-01-01
A study evaluating alternative methods for long term operation of biomass production systems was recently completed at the Kennedy Space Center (KSC). The 418-day study evaluated repeated batch versus mixed-aged production of potato grown on either standard 1/2-strength Hoagland's nutrient solution or solutions including nutrients recycled from inedible plant material. The long term effects of closure and recycling on microbial dynamics were evaluated by monitoring the microbial communities associated with various habitats within the plant growth system (i.e., plant roots, nutrient solution, biofilms within the hydroponic systems, atmosphere, and atmospheric condensate). Plate count methods were used to enumerate and characterize microorganisms. Microscopic staining methods were used to estimate total cell densities. The primary finding was that the density and composition of microbial communities associated with controlled environmental plant growth systems are stable during long term operation. Continuous production resulted in slightly greater stability. Nutrient recycling, despite the addition of soluble organic material from the waste processing system, did not significantly increase microbial density in any of the habitats.
NASA Astrophysics Data System (ADS)
1997-01-01
A study evaluating alternative methods for long term operation of biomass production systems was recently completed at the Kennedy Space Center (KSC). The 418-day study evaluated repeated batch versus mixed-aged production of potato grown on either standard
42 CFR 418.25 - Admission to hospice care.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 3 2010-10-01 2010-10-01 false Admission to hospice care. 418.25 Section 418.25... (CONTINUED) MEDICARE PROGRAM HOSPICE CARE Eligibility, Election and Duration of Benefits § 418.25 Admission to hospice care. (a) The hospice admits a patient only on the recommendation of the medical director...
42 CFR 418.70 - Condition of participation: Furnishing of non-core services.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 3 2011-10-01 2011-10-01 false Condition of participation: Furnishing of non-core services. 418.70 Section 418.70 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF... Care Non-Core Services § 418.70 Condition of participation: Furnishing of non-core services. A hospice...
20 CFR 418.2205 - What is a major life-changing event?
Code of Federal Regulations, 2011 CFR
2011-04-01
... 20 Employees' Benefits 2 2011-04-01 2011-04-01 false What is a major life-changing event? 418.2205 Section 418.2205 Employees' Benefits SOCIAL SECURITY ADMINISTRATION MEDICARE SUBSIDIES Income-Related... Year's Modified Adjusted Gross Income § 418.2205 What is a major life-changing event? We will follow...
20 CFR 418.2210 - What is not a major life-changing event?
Code of Federal Regulations, 2011 CFR
2011-04-01
... 20 Employees' Benefits 2 2011-04-01 2011-04-01 false What is not a major life-changing event? 418.2210 Section 418.2210 Employees' Benefits SOCIAL SECURITY ADMINISTRATION MEDICARE SUBSIDIES Income... Recent Tax Year's Modified Adjusted Gross Income § 418.2210 What is not a major life-changing event? We...
42 CFR 418.70 - Condition of participation: Furnishing of non-core services.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 3 2010-10-01 2010-10-01 false Condition of participation: Furnishing of non-core services. 418.70 Section 418.70 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF... Care Non-Core Services § 418.70 Condition of participation: Furnishing of non-core services. A hospice...
20 CFR 418.1260 - What major life-changing event evidence will we not accept?
Code of Federal Regulations, 2012 CFR
2012-04-01
... 20 Employees' Benefits 2 2012-04-01 2012-04-01 false What major life-changing event evidence will we not accept? 418.1260 Section 418.1260 Employees' Benefits SOCIAL SECURITY ADMINISTRATION MEDICARE... Year's Modified Adjusted Gross Income § 418.1260 What major life-changing event evidence will we not...
20 CFR 418.2205 - What is a major life-changing event?
Code of Federal Regulations, 2012 CFR
2012-04-01
... 20 Employees' Benefits 2 2012-04-01 2012-04-01 false What is a major life-changing event? 418.2205 Section 418.2205 Employees' Benefits SOCIAL SECURITY ADMINISTRATION MEDICARE SUBSIDIES Income-Related... Year's Modified Adjusted Gross Income § 418.2205 What is a major life-changing event? We will follow...
20 CFR 418.3115 - What events will make you ineligible for a subsidy?
Code of Federal Regulations, 2012 CFR
2012-04-01
... 20 Employees' Benefits 2 2012-04-01 2012-04-01 false What events will make you ineligible for a subsidy? 418.3115 Section 418.3115 Employees' Benefits SOCIAL SECURITY ADMINISTRATION MEDICARE SUBSIDIES Medicare Part D Subsidies Eligibility for A Medicare Prescription Drug Subsidy § 418.3115 What events will...
20 CFR 418.2210 - What is not a major life-changing event?
Code of Federal Regulations, 2012 CFR
2012-04-01
... 20 Employees' Benefits 2 2012-04-01 2012-04-01 false What is not a major life-changing event? 418.2210 Section 418.2210 Employees' Benefits SOCIAL SECURITY ADMINISTRATION MEDICARE SUBSIDIES Income... Recent Tax Year's Modified Adjusted Gross Income § 418.2210 What is not a major life-changing event? We...
20 CFR 418.2210 - What is not a major life-changing event?
Code of Federal Regulations, 2014 CFR
2014-04-01
... 20 Employees' Benefits 2 2014-04-01 2014-04-01 false What is not a major life-changing event? 418.2210 Section 418.2210 Employees' Benefits SOCIAL SECURITY ADMINISTRATION MEDICARE SUBSIDIES Income... Recent Tax Year's Modified Adjusted Gross Income § 418.2210 What is not a major life-changing event? We...
20 CFR 418.2205 - What is a major life-changing event?
Code of Federal Regulations, 2013 CFR
2013-04-01
... 20 Employees' Benefits 2 2013-04-01 2013-04-01 false What is a major life-changing event? 418.2205 Section 418.2205 Employees' Benefits SOCIAL SECURITY ADMINISTRATION MEDICARE SUBSIDIES Income-Related... Year's Modified Adjusted Gross Income § 418.2205 What is a major life-changing event? We will follow...
20 CFR 418.3115 - What events will make you ineligible for a subsidy?
Code of Federal Regulations, 2010 CFR
2010-04-01
... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false What events will make you ineligible for a subsidy? 418.3115 Section 418.3115 Employees' Benefits SOCIAL SECURITY ADMINISTRATION MEDICARE SUBSIDIES Medicare Part D Subsidies Eligibility for A Medicare Prescription Drug Subsidy § 418.3115 What events will...
20 CFR 418.2205 - What is a major life-changing event?
Code of Federal Regulations, 2014 CFR
2014-04-01
... 20 Employees' Benefits 2 2014-04-01 2014-04-01 false What is a major life-changing event? 418.2205 Section 418.2205 Employees' Benefits SOCIAL SECURITY ADMINISTRATION MEDICARE SUBSIDIES Income-Related... Year's Modified Adjusted Gross Income § 418.2205 What is a major life-changing event? We will follow...
20 CFR 418.3115 - What events will make you ineligible for a subsidy?
Code of Federal Regulations, 2014 CFR
2014-04-01
... 20 Employees' Benefits 2 2014-04-01 2014-04-01 false What events will make you ineligible for a subsidy? 418.3115 Section 418.3115 Employees' Benefits SOCIAL SECURITY ADMINISTRATION MEDICARE SUBSIDIES Medicare Part D Subsidies Eligibility for A Medicare Prescription Drug Subsidy § 418.3115 What events will...
20 CFR 418.1260 - What major life-changing event evidence will we not accept?
Code of Federal Regulations, 2014 CFR
2014-04-01
... 20 Employees' Benefits 2 2014-04-01 2014-04-01 false What major life-changing event evidence will we not accept? 418.1260 Section 418.1260 Employees' Benefits SOCIAL SECURITY ADMINISTRATION MEDICARE... Year's Modified Adjusted Gross Income § 418.1260 What major life-changing event evidence will we not...
20 CFR 418.3123 - When is a change in your subsidy effective?
Code of Federal Regulations, 2010 CFR
2010-04-01
... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false When is a change in your subsidy effective? 418.3123 Section 418.3123 Employees' Benefits SOCIAL SECURITY ADMINISTRATION MEDICARE SUBSIDIES Medicare Part D Subsidies Eligibility for A Medicare Prescription Drug Subsidy § 418.3123 When is a change...
20 CFR 418.2225 - Which more recent tax year will we use?
Code of Federal Regulations, 2012 CFR
2012-04-01
... 20 Employees' Benefits 2 2012-04-01 2012-04-01 false Which more recent tax year will we use? 418.2225 Section 418.2225 Employees' Benefits SOCIAL SECURITY ADMINISTRATION MEDICARE SUBSIDIES Income... Recent Tax Year's Modified Adjusted Gross Income § 418.2225 Which more recent tax year will we use? We...
20 CFR 418.2225 - Which more recent tax year will we use?
Code of Federal Regulations, 2013 CFR
2013-04-01
... 20 Employees' Benefits 2 2013-04-01 2013-04-01 false Which more recent tax year will we use? 418.2225 Section 418.2225 Employees' Benefits SOCIAL SECURITY ADMINISTRATION MEDICARE SUBSIDIES Income... Recent Tax Year's Modified Adjusted Gross Income § 418.2225 Which more recent tax year will we use? We...
20 CFR 418.2225 - Which more recent tax year will we use?
Code of Federal Regulations, 2011 CFR
2011-04-01
... 20 Employees' Benefits 2 2011-04-01 2011-04-01 false Which more recent tax year will we use? 418.2225 Section 418.2225 Employees' Benefits SOCIAL SECURITY ADMINISTRATION MEDICARE SUBSIDIES Income... Recent Tax Year's Modified Adjusted Gross Income § 418.2225 Which more recent tax year will we use? We...
20 CFR 418.2225 - Which more recent tax year will we use?
Code of Federal Regulations, 2014 CFR
2014-04-01
... 20 Employees' Benefits 2 2014-04-01 2014-04-01 false Which more recent tax year will we use? 418.2225 Section 418.2225 Employees' Benefits SOCIAL SECURITY ADMINISTRATION MEDICARE SUBSIDIES Income... Recent Tax Year's Modified Adjusted Gross Income § 418.2225 Which more recent tax year will we use? We...
20 CFR 418.1105 - What is the threshold?
Code of Federal Regulations, 2011 CFR
2011-04-01
... 20 Employees' Benefits 2 2011-04-01 2011-04-01 false What is the threshold? 418.1105 Section 418.1105 Employees' Benefits SOCIAL SECURITY ADMINISTRATION MEDICARE SUBSIDIES Medicare Part B Income-Related Monthly Adjustment Amount Determination of the Income-Related Monthly Adjustment Amount § 418.1105 What is the threshold? (a) The threshold is a...
20 CFR 418.2105 - What is the threshold?
Code of Federal Regulations, 2012 CFR
2012-04-01
... 20 Employees' Benefits 2 2012-04-01 2012-04-01 false What is the threshold? 418.2105 Section 418... Adjustment Amount § 418.2105 What is the threshold? (a) The threshold is a level of modified adjusted gross... years 2011 through and including 2019, the modified adjusted gross income threshold is $85,000 for...
20 CFR 418.1105 - What is the threshold?
Code of Federal Regulations, 2013 CFR
2013-04-01
... 20 Employees' Benefits 2 2013-04-01 2013-04-01 false What is the threshold? 418.1105 Section 418.1105 Employees' Benefits SOCIAL SECURITY ADMINISTRATION MEDICARE SUBSIDIES Medicare Part B Income-Related Monthly Adjustment Amount Determination of the Income-Related Monthly Adjustment Amount § 418.1105 What is the threshold? (a) The threshold is a...
20 CFR 418.1105 - What is the threshold?
Code of Federal Regulations, 2010 CFR
2010-04-01
... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false What is the threshold? 418.1105 Section 418.1105 Employees' Benefits SOCIAL SECURITY ADMINISTRATION MEDICARE SUBSIDIES Medicare Part B Income-Related Monthly Adjustment Amount Determination of the Income-Related Monthly Adjustment Amount § 418.1105 What is the threshold? (a) The threshold is a...
20 CFR 418.1105 - What is the threshold?
Code of Federal Regulations, 2014 CFR
2014-04-01
... 20 Employees' Benefits 2 2014-04-01 2014-04-01 false What is the threshold? 418.1105 Section 418.1105 Employees' Benefits SOCIAL SECURITY ADMINISTRATION MEDICARE SUBSIDIES Medicare Part B Income-Related Monthly Adjustment Amount Determination of the Income-Related Monthly Adjustment Amount § 418.1105 What is the threshold? (a) The threshold is a...
RECRUITMENT OF U.S. CITIZENS FOR VACANCIES IN IAEA SAFEGUARDS
DOE Office of Scientific and Technical Information (OSTI.GOV)
PEPPER,S.E.; DECARO,D.; WILLIAMS,G.
The International Atomic Energy Agency (IAEA) relies on its member states to assist with recruiting qualified individuals for positions within the IAEA's secretariat. It is important that persons within and outside the US nuclear and safeguards industries become aware of career opportunities available at the IAEA, and informed about important vacancies. The IAEA has established an impressive web page to advertise opportunities for employment. However, additional effort is necessary to ensure that there is sufficient awareness in the US of these opportunities, and assistance for persons interested in taking positions at the IAEA. In 1998, the Subgroup on Safeguards Technicalmore » Support (SSTS) approved a special task under the US Support Program to IAEA Safeguards (USSP) for improving US efforts to identify qualified candidates for vacancies in IAEA's Department of Safeguards. The International Safeguards Project Office (ISPO) developed a plan that includes increased advertising, development of a web page to support US recruitment efforts, feedback from the US Mission in Vienna, and interaction with other recruitment services provided by US professional organizations. The main purpose of this effort is to educate US citizens about opportunities at the IAEA so that qualified candidates can be identified for the IAEA's consideration.« less
10 CFR 75.6 - Facility and location reporting.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 2 2010-01-01 2010-01-01 false Facility and location reporting. 75.6 Section 75.6 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA..., all communications concerning the regulations in this Part shall be addressed to the U.S. Nuclear...
10 CFR 75.6 - Facility and location reporting.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 2 2013-01-01 2013-01-01 false Facility and location reporting. 75.6 Section 75.6 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA..., all communications concerning the regulations in this Part shall be addressed to the U.S. Nuclear...
10 CFR 75.6 - Facility and location reporting.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 2 2012-01-01 2012-01-01 false Facility and location reporting. 75.6 Section 75.6 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA..., all communications concerning the regulations in this Part shall be addressed to the U.S. Nuclear...
10 CFR 75.6 - Facility and location reporting.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 2 2014-01-01 2014-01-01 false Facility and location reporting. 75.6 Section 75.6 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA..., all communications concerning the regulations in this Part shall be addressed to the U.S. Nuclear...
10 CFR 75.6 - Facility and location reporting.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 2 2011-01-01 2011-01-01 false Facility and location reporting. 75.6 Section 75.6 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA..., all communications concerning the regulations in this Part shall be addressed to the U.S. Nuclear...
10 CFR 75.36 - Special reports.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 2 2011-01-01 2011-01-01 false Special reports. 75.36 Section 75.36 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA AGREEMENT Reports § 75.36 Special reports. (a) This section applies only to licenses or certificate holders who have been...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 2 2010-01-01 2010-01-01 false Violations. 75.51 Section 75.51 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA AGREEMENT Enforcement § 75.51 Violations. (a) The Commission may obtain an injunction or other court order to prevent a violation of the...
10 CFR 75.44 - Timing of advance notification.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 2 2011-01-01 2011-01-01 false Timing of advance notification. 75.44 Section 75.44 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA AGREEMENT Advanced Notification and Expenses § 75.44 Timing of advance notification. (a) Except as provided...
10 CFR 75.44 - Timing of advance notification.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 2 2010-01-01 2010-01-01 false Timing of advance notification. 75.44 Section 75.44 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA AGREEMENT Advanced Notification and Expenses § 75.44 Timing of advance notification. (a) Except as provided...
10 CFR 75.53 - Criminal penalties.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 2 2011-01-01 2011-01-01 false Criminal penalties. 75.53 Section 75.53 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA AGREEMENT Enforcement § 75.53 Criminal penalties. (a) Section 223 of the Atomic Energy Act of 1954, as amended, provides...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 2 2011-01-01 2011-01-01 false Violations. 75.51 Section 75.51 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA AGREEMENT Enforcement § 75.51 Violations. (a) The Commission may obtain an injunction or other court order to prevent a violation of the...
10 CFR 75.53 - Criminal penalties.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 2 2010-01-01 2010-01-01 false Criminal penalties. 75.53 Section 75.53 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA AGREEMENT Enforcement § 75.53 Criminal penalties. (a) Section 223 of the Atomic Energy Act of 1954, as amended, provides...
10 CFR 75.36 - Special reports.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 2 2010-01-01 2010-01-01 false Special reports. 75.36 Section 75.36 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA AGREEMENT Reports § 75.36 Special reports. (a) This section applies only to licenses or certificate holders who have been...
43 CFR Appendix A to Part 418 - Calculation of Efficiency Equation
Code of Federal Regulations, 2011 CFR
2011-10-01
... 43 Public Lands: Interior 1 2011-10-01 2011-10-01 false Calculation of Efficiency Equation A Appendix A to Part 418 Public Lands: Interior Regulations Relating to Public Lands BUREAU OF RECLAMATION.... 418, App. A Appendix A to Part 418—Calculation of Efficiency Equation ER18DE97.008 ER18DE97.009 ...
43 CFR Appendix A to Part 418 - Calculation of Efficiency Equation
Code of Federal Regulations, 2010 CFR
2010-10-01
... 43 Public Lands: Interior 1 2010-10-01 2010-10-01 false Calculation of Efficiency Equation A Appendix A to Part 418 Public Lands: Interior Regulations Relating to Public Lands BUREAU OF RECLAMATION.... 418, App. A Appendix A to Part 418—Calculation of Efficiency Equation ER18DE97.008 ER18DE97.009 ...
20 CFR 418.1210 - What is not a major life-changing event?
Code of Federal Regulations, 2011 CFR
2011-04-01
... 20 Employees' Benefits 2 2011-04-01 2011-04-01 false What is not a major life-changing event? 418.1210 Section 418.1210 Employees' Benefits SOCIAL SECURITY ADMINISTRATION MEDICARE SUBSIDIES Medicare... Adjusted Gross Income § 418.1210 What is not a major life-changing event? We will not consider events other...
20 CFR 418.2260 - What major life-changing event evidence will we not accept?
Code of Federal Regulations, 2011 CFR
2011-04-01
... 20 Employees' Benefits 2 2011-04-01 2011-04-01 false What major life-changing event evidence will we not accept? 418.2260 Section 418.2260 Employees' Benefits SOCIAL SECURITY ADMINISTRATION MEDICARE... Using A More Recent Tax Year's Modified Adjusted Gross Income § 418.2260 What major life-changing event...
20 CFR 418.2260 - What major life-changing event evidence will we not accept?
Code of Federal Regulations, 2012 CFR
2012-04-01
... 20 Employees' Benefits 2 2012-04-01 2012-04-01 false What major life-changing event evidence will we not accept? 418.2260 Section 418.2260 Employees' Benefits SOCIAL SECURITY ADMINISTRATION MEDICARE... Using A More Recent Tax Year's Modified Adjusted Gross Income § 418.2260 What major life-changing event...
20 CFR 418.2260 - What major life-changing event evidence will we not accept?
Code of Federal Regulations, 2014 CFR
2014-04-01
... 20 Employees' Benefits 2 2014-04-01 2014-04-01 false What major life-changing event evidence will we not accept? 418.2260 Section 418.2260 Employees' Benefits SOCIAL SECURITY ADMINISTRATION MEDICARE... Using A More Recent Tax Year's Modified Adjusted Gross Income § 418.2260 What major life-changing event...
Code of Federal Regulations, 2010 CFR
2010-04-01
... determination made by us ever appropriate? 418.1345 Section 418.1345 Employees' Benefits SOCIAL SECURITY... Administrative Review Process § 418.1345 Is reopening of an initial or reconsidered determination made by us ever appropriate? We may reopen an initial or reconsidered determination made by us when the conditions for...
Code of Federal Regulations, 2011 CFR
2011-04-01
... determination made by us ever appropriate? 418.1345 Section 418.1345 Employees' Benefits SOCIAL SECURITY... Administrative Review Process § 418.1345 Is reopening of an initial or reconsidered determination made by us ever appropriate? We may reopen an initial or reconsidered determination made by us when the conditions for...
20 CFR 418.1210 - What is not a major life-changing event?
Code of Federal Regulations, 2010 CFR
2010-04-01
... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false What is not a major life-changing event? 418.1210 Section 418.1210 Employees' Benefits SOCIAL SECURITY ADMINISTRATION MEDICARE SUBSIDIES Medicare... Adjusted Gross Income § 418.1210 What is not a major life-changing event? We will not consider events other...
20 CFR 418.1205 - What is a major life-changing event?
Code of Federal Regulations, 2010 CFR
2010-04-01
... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false What is a major life-changing event? 418.1205 Section 418.1205 Employees' Benefits SOCIAL SECURITY ADMINISTRATION MEDICARE SUBSIDIES Medicare Part B... Gross Income § 418.1205 What is a major life-changing event? For the purposes of this subpart, we will...
Kerepesi, Csaba; Szalkai, Balázs; Varga, Bálint; Grolmusz, Vince
2016-01-01
The human braingraph or the connectome is the object of an intensive research today. The advantage of the graph-approach to brain science is that the rich structures, algorithms and definitions of graph theory can be applied to the anatomical networks of the connections of the human brain. In these graphs, the vertices correspond to the small (1-1.5 cm2) areas of the gray matter, and two vertices are connected by an edge, if a diffusion-MRI based workflow finds fibers of axons, running between those small gray matter areas in the white matter of the brain. One main question of the field today is discovering the directions of the connections between the small gray matter areas. In a previous work we have reported the construction of the Budapest Reference Connectome Server http://connectome.pitgroup.org from the data recorded in the Human Connectome Project of the NIH. The server generates the consensus braingraph of 96 subjects in Version 2, and of 418 subjects in Version 3, according to selectable parameters. After the Budapest Reference Connectome Server had been published, we recognized a surprising and unforeseen property of the server. The server can generate the braingraph of connections that are present in at least k graphs out of the 418, for any value of k = 1, 2, …, 418. When the value of k is changed from k = 418 through 1 by moving a slider at the webserver from right to left, certainly more and more edges appear in the consensus graph. The astonishing observation is that the appearance of the new edges is not random: it is similar to a growing shrub. We refer to this phenomenon as the Consensus Connectome Dynamics. We hypothesize that this movement of the slider in the webserver may copy the development of the connections in the human brain in the following sense: the connections that are present in all subjects are the oldest ones, and those that are present only in a decreasing fraction of the subjects are gradually the newer connections in the individual brain development. An animation on the phenomenon is available at https://youtu.be/yxlyudPaVUE. Based on this observation and the related hypothesis, we can assign directions to some of the edges of the connectome as follows: Let Gk + 1 denote the consensus connectome where each edge is present in at least k+1 graphs, and let Gk denote the consensus connectome where each edge is present in at least k graphs. Suppose that vertex v is not connected to any other vertices in Gk+1, and becomes connected to a vertex u in Gk, where u was connected to other vertices already in Gk+1. Then we direct this (v, u) edge from v to u.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Drzymala, R. E., E-mail: drzymala@wustl.edu; Alvarez, P. E.; Bednarz, G.
2015-11-15
Purpose: Absorbed dose calibration for gamma stereotactic radiosurgery is challenging due to the unique geometric conditions, dosimetry characteristics, and nonstandard field size of these devices. Members of the American Association of Physicists in Medicine (AAPM) Task Group 178 on Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance have participated in a round-robin exchange of calibrated measurement instrumentation and phantoms exploring two approved and two proposed calibration protocols or formalisms on ten gamma radiosurgery units. The objectives of this study were to benchmark and compare new formalisms to existing calibration methods, while maintaining traceability to U.S. primary dosimetry calibration laboratory standards. Methods:more » Nine institutions made measurements using ten gamma stereotactic radiosurgery units in three different 160 mm diameter spherical phantoms [acrylonitrile butadiene styrene (ABS) plastic, Solid Water, and liquid water] and in air using a positioning jig. Two calibrated miniature ionization chambers and one calibrated electrometer were circulated for all measurements. Reference dose-rates at the phantom center were determined using the well-established AAPM TG-21 or TG-51 dose calibration protocols and using two proposed dose calibration protocols/formalisms: an in-air protocol and a formalism proposed by the International Atomic Energy Agency (IAEA) working group for small and nonstandard radiation fields. Each institution’s results were normalized to the dose-rate determined at that institution using the TG-21 protocol in the ABS phantom. Results: Percentages of dose-rates within 1.5% of the reference dose-rate (TG-21 + ABS phantom) for the eight chamber-protocol-phantom combinations were the following: 88% for TG-21, 70% for TG-51, 93% for the new IAEA nonstandard-field formalism, and 65% for the new in-air protocol. Averages and standard deviations for dose-rates over all measurements relative to the TG-21 + ABS dose-rate were 0.999 ± 0.009 (TG-21), 0.991 ± 0.013 (TG-51), 1.000 ± 0.009 (IAEA), and 1.009 ± 0.012 (in-air). There were no statistically significant differences (i.e., p > 0.05) between the two ionization chambers for the TG-21 protocol applied to all dosimetry phantoms. The mean results using the TG-51 protocol were notably lower than those for the other dosimetry protocols, with a standard deviation 2–3 times larger. The in-air protocol was not statistically different from TG-21 for the A16 chamber in the liquid water or ABS phantoms (p = 0.300 and p = 0.135) but was statistically different from TG-21 for the PTW chamber in all phantoms (p = 0.006 for Solid Water, 0.014 for liquid water, and 0.020 for ABS). Results of IAEA formalism were statistically different from TG-21 results only for the combination of the A16 chamber with the liquid water phantom (p = 0.017). In the latter case, dose-rates measured with the two protocols differed by only 0.4%. For other phantom-ionization-chamber combinations, the new IAEA formalism was not statistically different from TG-21. Conclusions: Although further investigation is needed to validate the new protocols for other ionization chambers, these results can serve as a reference to quantitatively compare different calibration protocols and ionization chambers if a particular method is chosen by a professional society to serve as a standardized calibration protocol.« less
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 2 2010-07-01 2010-07-01 false When will funds be disbursed to Gulf producing States and eligible coastal political subdivisions? 219.418 Section 219.418 Mineral Resources MINERALS... ROYALTIES, RENTALS, AND BONUSES Oil and Gas, Offshore § 219.418 When will funds be disbursed to Gulf...
Code of Federal Regulations, 2011 CFR
2011-04-01
... modified adjusted gross income reduction will you need to support your request? 418.2265 Section 418.2265 Employees' Benefits SOCIAL SECURITY ADMINISTRATION MEDICARE SUBSIDIES Income-Related Monthly Adjustments to... reduction will you need to support your request? We will follow the rules in § 418.1265, except that any...
20 CFR 418.1210 - What is not a major life-changing event?
Code of Federal Regulations, 2012 CFR
2012-04-01
... 20 Employees' Benefits 2 2012-04-01 2012-04-01 false What is not a major life-changing event? 418... Adjusted Gross Income § 418.1210 What is not a major life-changing event? We will not consider events other than those described in § 418.1205 to be major life-changing events. Certain types of events are not...
20 CFR 418.1210 - What is not a major life-changing event?
Code of Federal Regulations, 2014 CFR
2014-04-01
... 20 Employees' Benefits 2 2014-04-01 2014-04-01 false What is not a major life-changing event? 418... Adjusted Gross Income § 418.1210 What is not a major life-changing event? We will not consider events other than those described in § 418.1205 to be major life-changing events. Certain types of events are not...
Code of Federal Regulations, 2011 CFR
2011-04-01
... 20 Employees' Benefits 2 2011-04-01 2011-04-01 false Is reopening of an initial or reconsidered determination made by us ever appropriate? 418.2345 Section 418.2345 Employees' Benefits SOCIAL SECURITY... reconsidered determination made by us ever appropriate? We will follow the rules in § 418.1345, except that any...
High resolution isotopic analysis of U-bearing particles via fusion of SIMS and EDS images
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tarolli, Jay G.; Naes, Benjamin E.; Garcia, Benjamin J.
Image fusion of secondary ion mass spectrometry (SIMS) images and X-ray elemental maps from energy-dispersive spectroscopy (EDS) was performed to facilitate the isolation and re-analysis of isotopically unique U-bearing particles where the highest precision SIMS measurements are required. Image registration, image fusion and particle micromanipulation were performed on a subset of SIMS images obtained from a large area pre-screen of a particle distribution from a sample containing several certified reference materials (CRM) U129A, U015, U150, U500 and U850, as well as a standard reference material (SRM) 8704 (Buffalo River Sediment) to simulate particles collected on swipes during routine inspections ofmore » declared uranium enrichment facilities by the International Atomic Energy Agency (IAEA). In total, fourteen particles, ranging in size from 5 – 15 µm, were isolated and re-analyzed by SIMS in multi-collector mode identifying nine particles of CRM U129A, one of U150, one of U500 and three of U850. These identifications were made within a few percent errors from the National Institute of Standards and Technology (NIST) certified atom percent values for 234U, 235U and 238U for the corresponding CRMs. This work represents the first use of image fusion to enhance the accuracy and precision of isotope ratio measurements for isotopically unique U-bearing particles for nuclear safeguards applications. Implementation of image fusion is essential for the identification of particles of interests that fall below the spatial resolution of the SIMS images.« less
Pollution Monitoring: An Engineering Challenge
NASA Technical Reports Server (NTRS)
Snodgrass, J. M.
1971-01-01
One purpose in presenting this material is to bring to the attention of engineers background material which they would not normally encounter in the course of routine development work. An excellent and timely reference is as follows: Seminar on Methods of Detection, Measurement and Monitoring of Pollutants in the Marine Environment. The international seminar was organized by FAO with the support of UNESCO, IAEA, SCOR and WMO, and was held in Rome, Italy, 4-10 December 1970. The final report, the title of which was given, is a very thoroughgoing document and certainly a must reference for anyone seriously considering the development of sensors for pollution measurement. Perhaps it would be appropriate to present some exact quotations selected from the referenced document. The quotations follow: 1) "The pressures to develop sensitive and reliable methods come about when those responsible for the management of our environment need an objective evaluation of existing or potential perils." 2) "Nearly all of the Panels concerned with the contaminants identified specific examples of man's waste products which may be leaking to the environment in substantial quantities and for which as yet there are no analytical techniques available ". 3) "Very few analyses for organochlorine pesticides appear to have been carried out on sea water and the panel considered that the present methodology was not capable of detecting, on a routine basis, the quantities of these compounds in open sea waters." and 4) "This corresponds essentially to the ratio of useful data produced to the labour expended, since instrumentation costs in the long run become negligible."
A far-infrared emission feature in carbon-rich stars and planetary nebulae
NASA Technical Reports Server (NTRS)
Forrest, W. J.; Houck, J. R.; Mccarthy, J. F.
1981-01-01
The 16-30 micron spectra of several carbon stars and the planetary nebulae IC 418 and NGC 6572 have been obtained using the NASA C-141 Kuiper Airborne Observatory. A newly observed emission feature appears in the spectrum of IRC +10216 and several other carbon stars at wavelengths greater than 24 microns. The feature is interpreted as resulting from a solid-state resonance in the dust grains which have condensed around these stars. A similar feature appears in the spectra of IC 418 and NGC 6572, implying that the same type of dust is present. Since the dust probably condensed from a carbon-rich gas, this indicates an evolutionary link between carbon stars and these planetary nebulae. No identification for the grain material has been found, but some clues are apparent which could aid in the identification.
Comparison of IPSM 1990 photon dosimetry code of practice with IAEA TRS‐398 and AAPM TG‐51.
Henríquez, Francisco Cutanda
2009-01-01
Several codes of practice for photon dosimetry are currently used around the world, supported by different organizations. A comparison of IPSM 1990 with both IAEA TRS‐398 and AAPM TG‐51 has been performed. All three protocols are based on the calibration of ionization chambers in terms of standards of absorbed dose to water, as it is the case with other modern codes of practice. This comparison has been carried out for photon beams of nominal energies: 4 MV, 6 MV, 8 MV, 10 MV and 18 MV. An NE 2571 graphite ionization chamber was used in this study, cross‐calibrated against an NE 2611A Secondary Standard, calibrated in the National Physical Laboratory (NPL). Absolute dose in reference conditions was obtained using each of these three protocols including: beam quality indices, beam quality conversion factors both theoretical and NPL experimental ones, correction factors for influence quantities and absolute dose measurements. Each protocol recommendations have been strictly followed. Uncertainties have been obtained according to the ISO Guide to the Expression of Uncertainty in Measurement. Absorbed dose obtained according to all three protocols agree within experimental uncertainty. The largest difference between absolute dose results for two protocols is obtained for the highest energy: 0.7% between IPSM 1990 and IAEA TRS‐398 using theoretical beam quality conversion factors. PACS number: 87.55.tm
DOE Office of Scientific and Technical Information (OSTI.GOV)
Demuth, Scott F.; Trahan, Alexis Chanel
2017-06-26
DIV of facility layout, material flows, and other information provided in the DIQ. Material accountancy through an annual PIV and a number of interim inventory verifications, including UF6 cylinder identification and counting, NDA of cylinders, and DA on a sample collection of UF6. Application of C/S technologies utilizing seals and tamper-indicating devices (TIDs) on cylinders, containers, storage rooms, and IAEA instrumentation to provide continuity of knowledge between inspection. Verification of the absence of undeclared material and operations, especially HEU production, through SNRIs, LFUA of cascade halls, and environmental swipe sampling
NASA Astrophysics Data System (ADS)
Capote, R.; Herman, M.; Obložinský, P.; Young, P. G.; Goriely, S.; Belgya, T.; Ignatyuk, A. V.; Koning, A. J.; Hilaire, S.; Plujko, V. A.; Avrigeanu, M.; Bersillon, O.; Chadwick, M. B.; Fukahori, T.; Ge, Zhigang; Han, Yinlu; Kailas, S.; Kopecky, J.; Maslov, V. M.; Reffo, G.; Sin, M.; Soukhovitskii, E. Sh.; Talou, P.
2009-12-01
We describe the physics and data included in the Reference Input Parameter Library, which is devoted to input parameters needed in calculations of nuclear reactions and nuclear data evaluations. Advanced modelling codes require substantial numerical input, therefore the International Atomic Energy Agency (IAEA) has worked extensively since 1993 on a library of validated nuclear-model input parameters, referred to as the Reference Input Parameter Library (RIPL). A final RIPL coordinated research project (RIPL-3) was brought to a successful conclusion in December 2008, after 15 years of challenging work carried out through three consecutive IAEA projects. The RIPL-3 library was released in January 2009, and is available on the Web through http://www-nds.iaea.org/RIPL-3/. This work and the resulting database are extremely important to theoreticians involved in the development and use of nuclear reaction modelling (ALICE, EMPIRE, GNASH, UNF, TALYS) both for theoretical research and nuclear data evaluations. The numerical data and computer codes included in RIPL-3 are arranged in seven segments: MASSES contains ground-state properties of nuclei for about 9000 nuclei, including three theoretical predictions of masses and the evaluated experimental masses of Audi et al. (2003). DISCRETE LEVELS contains 117 datasets (one for each element) with all known level schemes, electromagnetic and γ-ray decay probabilities available from ENSDF in October 2007. NEUTRON RESONANCES contains average resonance parameters prepared on the basis of the evaluations performed by Ignatyuk and Mughabghab. OPTICAL MODEL contains 495 sets of phenomenological optical model parameters defined in a wide energy range. When there are insufficient experimental data, the evaluator has to resort to either global parameterizations or microscopic approaches. Radial density distributions to be used as input for microscopic calculations are stored in the MASSES segment. LEVEL DENSITIES contains phenomenological parameterizations based on the modified Fermi gas and superfluid models and microscopic calculations which are based on a realistic microscopic single-particle level scheme. Partial level densities formulae are also recommended. All tabulated total level densities are consistent with both the recommended average neutron resonance parameters and discrete levels. GAMMA contains parameters that quantify giant resonances, experimental gamma-ray strength functions and methods for calculating gamma emission in statistical model codes. The experimental GDR parameters are represented by Lorentzian fits to the photo-absorption cross sections for 102 nuclides ranging from 51V to 239Pu. FISSION includes global prescriptions for fission barriers and nuclear level densities at fission saddle points based on microscopic HFB calculations constrained by experimental fission cross sections.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Capote, R.; Herman, M.; Oblozinsky, P.
We describe the physics and data included in the Reference Input Parameter Library, which is devoted to input parameters needed in calculations of nuclear reactions and nuclear data evaluations. Advanced modelling codes require substantial numerical input, therefore the International Atomic Energy Agency (IAEA) has worked extensively since 1993 on a library of validated nuclear-model input parameters, referred to as the Reference Input Parameter Library (RIPL). A final RIPL coordinated research project (RIPL-3) was brought to a successful conclusion in December 2008, after 15 years of challenging work carried out through three consecutive IAEA projects. The RIPL-3 library was released inmore » January 2009, and is available on the Web through (http://www-nds.iaea.org/RIPL-3/). This work and the resulting database are extremely important to theoreticians involved in the development and use of nuclear reaction modelling (ALICE, EMPIRE, GNASH, UNF, TALYS) both for theoretical research and nuclear data evaluations. The numerical data and computer codes included in RIPL-3 are arranged in seven segments: MASSES contains ground-state properties of nuclei for about 9000 nuclei, including three theoretical predictions of masses and the evaluated experimental masses of Audi et al. (2003). DISCRETE LEVELS contains 117 datasets (one for each element) with all known level schemes, electromagnetic and {gamma}-ray decay probabilities available from ENSDF in October 2007. NEUTRON RESONANCES contains average resonance parameters prepared on the basis of the evaluations performed by Ignatyuk and Mughabghab. OPTICAL MODEL contains 495 sets of phenomenological optical model parameters defined in a wide energy range. When there are insufficient experimental data, the evaluator has to resort to either global parameterizations or microscopic approaches. Radial density distributions to be used as input for microscopic calculations are stored in the MASSES segment. LEVEL DENSITIES contains phenomenological parameterizations based on the modified Fermi gas and superfluid models and microscopic calculations which are based on a realistic microscopic single-particle level scheme. Partial level densities formulae are also recommended. All tabulated total level densities are consistent with both the recommended average neutron resonance parameters and discrete levels. GAMMA contains parameters that quantify giant resonances, experimental gamma-ray strength functions and methods for calculating gamma emission in statistical model codes. The experimental GDR parameters are represented by Lorentzian fits to the photo-absorption cross sections for 102 nuclides ranging from {sup 51}V to {sup 239}Pu. FISSION includes global prescriptions for fission barriers and nuclear level densities at fission saddle points based on microscopic HFB calculations constrained by experimental fission cross sections.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Capote, R.; Herman, M.; Capote,R.
We describe the physics and data included in the Reference Input Parameter Library, which is devoted to input parameters needed in calculations of nuclear reactions and nuclear data evaluations. Advanced modelling codes require substantial numerical input, therefore the International Atomic Energy Agency (IAEA) has worked extensively since 1993 on a library of validated nuclear-model input parameters, referred to as the Reference Input Parameter Library (RIPL). A final RIPL coordinated research project (RIPL-3) was brought to a successful conclusion in December 2008, after 15 years of challenging work carried out through three consecutive IAEA projects. The RIPL-3 library was released inmore » January 2009, and is available on the Web through http://www-nds.iaea.org/RIPL-3/. This work and the resulting database are extremely important to theoreticians involved in the development and use of nuclear reaction modelling (ALICE, EMPIRE, GNASH, UNF, TALYS) both for theoretical research and nuclear data evaluations. The numerical data and computer codes included in RIPL-3 are arranged in seven segments: MASSES contains ground-state properties of nuclei for about 9000 nuclei, including three theoretical predictions of masses and the evaluated experimental masses of Audi et al. (2003). DISCRETE LEVELS contains 117 datasets (one for each element) with all known level schemes, electromagnetic and {gamma}-ray decay probabilities available from ENSDF in October 2007. NEUTRON RESONANCES contains average resonance parameters prepared on the basis of the evaluations performed by Ignatyuk and Mughabghab. OPTICAL MODEL contains 495 sets of phenomenological optical model parameters defined in a wide energy range. When there are insufficient experimental data, the evaluator has to resort to either global parameterizations or microscopic approaches. Radial density distributions to be used as input for microscopic calculations are stored in the MASSES segment. LEVEL DENSITIES contains phenomenological parameterizations based on the modified Fermi gas and superfluid models and microscopic calculations which are based on a realistic microscopic single-particle level scheme. Partial level densities formulae are also recommended. All tabulated total level densities are consistent with both the recommended average neutron resonance parameters and discrete levels. GAMMA contains parameters that quantify giant resonances, experimental gamma-ray strength functions and methods for calculating gamma emission in statistical model codes. The experimental GDR parameters are represented by Lorentzian fits to the photo-absorption cross sections for 102 nuclides ranging from {sup 51}V to {sup 239}Pu. FISSION includes global prescriptions for fission barriers and nuclear level densities at fission saddle points based on microscopic HFB calculations constrained by experimental fission cross sections.« less
Physics and Its Multiple Roles in the International Atomic Energy Agency
NASA Astrophysics Data System (ADS)
Massey, Charles D.
2017-01-01
The IAEA is the world's centre for cooperation in the nuclear field. It was set up as the world's ``Atoms for Peace'' organization in 1957 within the United Nations family. The Agency works with its Member States and multiple partners worldwide to promote the safe, secure and peaceful use of nuclear technologies. Three main areas of work underpin the IAEA's mission: Safety and Security, Science and Technology, and Safeguards and Verification. To carry out its mission, the Agency is authorized to encourage and assist research on, and development and practical application of, atomic energy for peaceful uses throughout the world; foster the exchange of scientific and technical information on peaceful uses of atomic energy; and encourage the exchange of training of scientists and experts in the field of peaceful uses of atomic energy. Nowadays, nuclear physics and nuclear technology are applied in a great variety of social areas, such as power production, medical diagnosis and therapies, environmental protection, security control, material tests, food processing, waste treatments, agriculture and artifacts analysis. This presentation will cover the role and practical application of physics at the IAEA, and, in particular, focus on the role physics has, and will play, in nuclear security.
Databases and coordinated research projects at the IAEA on atomic processes in plasmas
NASA Astrophysics Data System (ADS)
Braams, Bastiaan J.; Chung, Hyun-Kyung
2012-05-01
The Atomic and Molecular Data Unit at the IAEA works with a network of national data centres to encourage and coordinate production and dissemination of fundamental data for atomic, molecular and plasma-material interaction (A+M/PMI) processes that are relevant to the realization of fusion energy. The Unit maintains numerical and bibliographical databases and has started a Wiki-style knowledge base. The Unit also contributes to A+M database interface standards and provides a search engine that offers a common interface to multiple numerical A+M/PMI databases. Coordinated Research Projects (CRPs) bring together fusion energy researchers and atomic, molecular and surface physicists for joint work towards the development of new data and new methods. The databases and current CRPs on A+M/PMI processes are briefly described here.
The IAEA stopping power database, following the trends in stopping power of ions in matter
NASA Astrophysics Data System (ADS)
Montanari, C. C.; Dimitriou, P.
2017-10-01
The aim of this work is to present an overview of the state of art of the energy loss of ions in matter, based on the new developments in the stopping power database of the International Atomic Energy Agency (IAEA). This exhaustive collection of experimental data, graphs, programs and comparisons, is the legacy of Helmut Paul, who made it accessible to the global scientific community, and has been extensively employed in theoretical and experimental research during the last 25 years. The field of stopping power in matter is evolving, with new trends in materials of interest, including oxides, nitrides, polymers, and biological targets. Our goal is to identify areas of interest and emerging data needs to meet the requirements of a continuously developing user community.
National Security to Nationalist Myth: Why Iran Wants Nuclear Weapons
2004-09-01
Atomic Energy Organization of Iran ( AEOI ),81 as well as Iran’s nuclear technology suppliers. By publicly embracing the “nuclear insecurity” myth and...81 The literature variously refers to the Atomic Energy Organization of Iran as “ AEOI ,” or “IAEO...I have adopted “ AEOI ,” the form used by the IAEA, except where quoting other sources. See “Implementation of the NPT Safeguards Agreement in the
Nominations for the 2017 NNSA Pollution Prevention Awards
DOE Office of Scientific and Technical Information (OSTI.GOV)
Salzman, Sonja L.; Ballesteros Rodriguez, Sonia; Lopez, Lorraine Bonds
In the field of nuclear forensics, one of the biggest challenges is to dissolve postdetonation debris for analysis. Debris generated after a nuclear detonation is a glassy material that is difficult to dissolve with chemicals. Traditionally, concentrated nitric acid, hydrofluoric acid, or sulfuric acid are employed during the dissolution. These acids, due to their corrosive nature, are not suitable for in-field/on-site sample preparations. Uranium oxides are commonly present in nuclear fuel processing plants and nuclear research facilities. In uranium oxides, the level of uranium isotope enrichment is a sensitive indicator for nuclear nonproliferation and is monitored closely by the Internationalmore » Atomic Energy Agency (IAEA) to ensure there is no misuse of nuclear material or technology for nuclear weapons. During an IAEA on-site inspection at a facility, environmental surface swipe samples are collected and transported to the IAEA headquarters or network of analytical laboratories for further processing. Uranium oxide particles collected on the swipe medium are typically dissolved with inorganic acids and are then analyzed for uranium isotopic compositions. To improve the responsiveness of on-site inspections, in-field detection techniques have been recently explored. However, in-field analysis is bottlenecked by time-consuming and hazardous dissolution procedures, as corrosive inorganic acids must be used. Corrosive chemicals are difficult to use in the field due to personnel safety considerations, and the transportation of such chemicals is highly regulated. It was therefore necessary to develop fast uranium oxide dissolution methods using less hazardous chemicals in support of the rapid infield detection of anomalies in declared nuclear processes.« less
Code of Federal Regulations, 2013 CFR
2013-04-01
... missing the deadline to request administrative review? 418.3640 Section 418.3640 Employees' Benefits... Administrative Review Process § 418.3640 How do we determine if you had good cause for missing the deadline to... missing a deadline to request review we consider: (1) What circumstances kept you from making the request...
Code of Federal Regulations, 2012 CFR
2012-04-01
... missing the deadline to request administrative review? 418.3640 Section 418.3640 Employees' Benefits... Administrative Review Process § 418.3640 How do we determine if you had good cause for missing the deadline to... missing a deadline to request review we consider: (1) What circumstances kept you from making the request...
Code of Federal Regulations, 2014 CFR
2014-04-01
... missing the deadline to request administrative review? 418.3640 Section 418.3640 Employees' Benefits... Administrative Review Process § 418.3640 How do we determine if you had good cause for missing the deadline to... missing a deadline to request review we consider: (1) What circumstances kept you from making the request...
Code of Federal Regulations, 2011 CFR
2011-04-01
... missing the deadline to request administrative review? 418.3640 Section 418.3640 Employees' Benefits... Administrative Review Process § 418.3640 How do we determine if you had good cause for missing the deadline to... missing a deadline to request review we consider: (1) What circumstances kept you from making the request...
Code of Federal Regulations, 2011 CFR
2011-04-01
...-changing event will you need to support your request for us to use a more recent tax year? 418.2255 Section 418.2255 Employees' Benefits SOCIAL SECURITY ADMINISTRATION MEDICARE SUBSIDIES Income-Related Monthly... Modified Adjusted Gross Income § 418.2255 What kind of evidence of a major life-changing event will you...
Code of Federal Regulations, 2014 CFR
2014-04-01
... modified adjusted gross income for the more recent tax year changes? 418.1245 Section 418.1245 Employees... Adjustment Amount Determinations Using A More Recent Tax Year's Modified Adjusted Gross Income § 418.1245 What will happen if you notify us that your modified adjusted gross income for the more recent tax year...
Code of Federal Regulations, 2012 CFR
2012-04-01
... modified adjusted gross income for the more recent tax year changes? 418.1245 Section 418.1245 Employees... Adjustment Amount Determinations Using A More Recent Tax Year's Modified Adjusted Gross Income § 418.1245 What will happen if you notify us that your modified adjusted gross income for the more recent tax year...
Code of Federal Regulations, 2013 CFR
2013-04-01
... modified adjusted gross income for the more recent tax year changes? 418.1245 Section 418.1245 Employees... Adjustment Amount Determinations Using A More Recent Tax Year's Modified Adjusted Gross Income § 418.1245 What will happen if you notify us that your modified adjusted gross income for the more recent tax year...
Code of Federal Regulations, 2011 CFR
2011-04-01
... modified adjusted gross income for the more recent tax year changes? 418.1245 Section 418.1245 Employees... Adjustment Amount Determinations Using A More Recent Tax Year's Modified Adjusted Gross Income § 418.1245 What will happen if you notify us that your modified adjusted gross income for the more recent tax year...
76 FR 29804 - Agency Information Collection Activities: Proposed Collection; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-23
... of 1995 (44 U.S.C. chapter 35). Information pertaining to the requirement to be submitted: 1. The title of the information collection: 10 CFR Part 75-- Safeguards on Nuclear Material, Implementation of US/IAEA Agreement. 2. Current OMB approval number: OMB 3150-0055. 3. How often the collection is...
77 FR 6094 - Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-07
....-International Atomic Energy Agency Additional Protocol. Under the U.S.-International Atomic Energy Agency (IAEA...-related activities to the IAEA and potentially provide access to IAEA inspectors for verification purposes. The U.S.-IAEA Additional Protocol permits the United States unilaterally to declare exclusions from...
Improving Quality and Access to Radiation Therapy-An IAEA Perspective.
Abdel-Wahab, May; Zubizarreta, Eduardo; Polo, Alfredo; Meghzifene, Ahmed
2017-04-01
The International Atomic Energy Agency (IAEA) has been involved in radiation therapy since soon after its creation in 1957. In response to the demands of Member States, the IAEA׳s activities relating to radiation therapy have focused on supporting low- and middle-income countries to set up radiation therapy facilities, expand the scope of treatments, or gradually transition to new technologies. In addition, the IAEA has been very active in providing internationally harmonized guidelines on clinical, dosimetry, medical physics, and safety aspects of radiation therapy. IAEA clinical research has provided evidence for treatment improvement as well as highly effective resource-sparing interventions. In the process, training of researchers occurs through this program. To provide this support, the IAEA works with its Member States and multiple partners worldwide through several mechanisms. In this article, we review the main activities conducted by the IAEA in support to radiation therapy. IAEA support has been crucial for achieving tangible results in many low- and middle-income countries. However, long-term sustainability of projects can present a challenge, especially when considering health budget constraints and the brain drain of skilled professionals. The need for support remains, with more than 90% of patients in low-income countries lacking access to radiotherapy. Thus, the IAEA is expected to continue its support and strengthen quality radiation therapy treatment of patients with cancer. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barefield Ii, James E; Clegg, Samuel M; Lopez, Leon N
2010-01-01
Advanced methodologies and improvements to current measurements techniques are needed to strengthen the effectiveness and efficiency of international safeguards. This need was recognized and discussed at a Technical Meeting on 'The Application of Laser Spectrometry Techniques in IAEA Safeguards' held at IAEA headquarters (September 2006). One of the principal recommendations from that meeting was the need to pursue the development of novel complementary access instrumentation based on Laser Induced Breakdown Spectroscopy (UBS) for the detection of gaseous and solid signatures and indicators of nuclear fuel cycle processes and associated materials'. Pursuant to this recommendation the Department of Safeguards (SG) undermore » the Division of Technical Support (SGTS) convened the 'Experts and Users Advisory Meeting on Laser Induced Breakdown Spectroscopy (LIBS) for Safeguards Applications' also held at IAEA headquarters (July 2008). This meeting was attended by 12 LlBS experts from the Czech Republic, the European Commission, France, the Republic of South Korea, the United States of America, Germany, the United Kingdom of Great Britain, Canada, and Northern Ireland. Following a presentation of the needs of the IAEA inspectors, the LIBS experts agreed that needs as presented could be partially or fully fulfilled using LIBS instrumentation. Inspectors needs were grouped into the following broad categories: (1) Improvements to in-field measurements/environmental sampling; (2) Monitoring status of activities in Hot Cells; (3) Verify status of activity at a declared facility via process monitoring; and (4) Need for pre-screening of environmental samples before analysis. The primary tool employed by the IAEA to detect undeclared processes and activities at special nuclear material facilities and sites is environmental sampling. One of the objectives of the Next Generation Safeguards Initiative (NGSI) Program Plan calls for the development of advanced tools and methodologies to detect and analyze undeclared processing or production of special nuclear material. Los Alamos National Laboratory is currently investigating potential uses of LIBS for safeguards applications, including (1) a user-friendly man-portable LIBS system to characterize samples in real to near-real time (typical analysis time are on the order of minutes) across a wide range of elements in the periodic table from hydrogen up to heavy elements like plutonium and uranium, (2) a LIBS system that can be deployed in harsh environments such as hot cells and glove boxes providing relative compositional analysis of process streams for example ratios like Cm/Up and Cm/U, (3) an inspector field deployable system that can be used to analyze the elemental composition of microscopic quantities of samples containing plutonium and uranium, and (4) a high resolution LIBS system that can be used to determine the isotopic composition of samples containing for example uranium, plutonium... etc. In this paper, we will describe our current development and performance testing results for LIBS instrumentation both in a fixed lab and measurements in field deployable configurations.« less
25 CFR 115.418 - What types of trust funds may a minor have?
Code of Federal Regulations, 2010 CFR
2010-04-01
... 25 Indians 1 2010-04-01 2010-04-01 false What types of trust funds may a minor have? 115.418 Section 115.418 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR FINANCIAL ACTIVITIES TRUST FUNDS FOR TRIBES AND INDIVIDUAL INDIANS IIM Accounts: Minors § 115.418 What types of trust funds may a minor have? A minor may have one or more of the...
Code of Federal Regulations, 2014 CFR
2014-04-01
... request that we use a more recent tax year? 418.1250 Section 418.1250 Employees' Benefits SOCIAL SECURITY... More Recent Tax Year's Modified Adjusted Gross Income § 418.1250 What evidence will you need to support your request that we use a more recent tax year? When you request that we use a more recent tax year to...
Code of Federal Regulations, 2013 CFR
2013-04-01
... request that we use a more recent tax year? 418.1250 Section 418.1250 Employees' Benefits SOCIAL SECURITY... More Recent Tax Year's Modified Adjusted Gross Income § 418.1250 What evidence will you need to support your request that we use a more recent tax year? When you request that we use a more recent tax year to...
Code of Federal Regulations, 2012 CFR
2012-04-01
... request that we use a more recent tax year? 418.2250 Section 418.2250 Employees' Benefits SOCIAL SECURITY... Premiums Determinations Using A More Recent Tax Year's Modified Adjusted Gross Income § 418.2250 What evidence will you need to support your request that we use a more recent tax year? We will follow the rules...
Code of Federal Regulations, 2014 CFR
2014-04-01
... request that we use a more recent tax year? 418.2250 Section 418.2250 Employees' Benefits SOCIAL SECURITY... Premiums Determinations Using A More Recent Tax Year's Modified Adjusted Gross Income § 418.2250 What evidence will you need to support your request that we use a more recent tax year? We will follow the rules...
Code of Federal Regulations, 2012 CFR
2012-04-01
... request that we use a more recent tax year? 418.1250 Section 418.1250 Employees' Benefits SOCIAL SECURITY... More Recent Tax Year's Modified Adjusted Gross Income § 418.1250 What evidence will you need to support your request that we use a more recent tax year? When you request that we use a more recent tax year to...
Code of Federal Regulations, 2013 CFR
2013-04-01
... request that we use a more recent tax year? 418.2250 Section 418.2250 Employees' Benefits SOCIAL SECURITY... Premiums Determinations Using A More Recent Tax Year's Modified Adjusted Gross Income § 418.2250 What evidence will you need to support your request that we use a more recent tax year? We will follow the rules...
A probabilistic safety analysis of incidents in nuclear research reactors.
Lopes, Valdir Maciel; Agostinho Angelo Sordi, Gian Maria; Moralles, Mauricio; Filho, Tufic Madi
2012-06-01
This work aims to evaluate the potential risks of incidents in nuclear research reactors. For its development, two databases of the International Atomic Energy Agency (IAEA) were used: the Research Reactor Data Base (RRDB) and the Incident Report System for Research Reactor (IRSRR). For this study, the probabilistic safety analysis (PSA) was used. To obtain the result of the probability calculations for PSA, the theory and equations in the paper IAEA TECDOC-636 were used. A specific program to analyse the probabilities was developed within the main program, Scilab 5.1.1. for two distributions, Fischer and chi-square, both with the confidence level of 90 %. Using Sordi equations, the maximum admissible doses to compare with the risk limits established by the International Commission on Radiological Protection (ICRP) were obtained. All results achieved with this probability analysis led to the conclusion that the incidents which occurred had radiation doses within the stochastic effects reference interval established by the ICRP-64.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Raffo-Caiado, Ana Claudia; Begovich, John M; Ferrada, Juan J
2008-01-01
In 2005, the National Nuclear Energy Commission of Brazil (CNEN) and the U.S. Department of Energy (DOE) agreed on a collaborative effort to evaluate measures that can strengthen the effectiveness of international safeguards at a natural uranium conversion plant (NUCP). The work was performed by DOE's Oak Ridge National Laboratory and CNEN. A generic model of an NUCP was developed and typical processing steps were defined. The study, completed in early 2007, identified potential safeguards measures and evaluated their effectiveness and impacts on operations. In addition, advanced instrumentation and techniques for verification purposes were identified and investigated. The scope ofmore » the work was framed by the International Atomic Energy Agency's (IAEA's) 2003 revised policy concerning the starting point of safeguards at uranium conversion facilities. Before this policy, only the final products of the uranium conversion plant were considered to be of composition and purity suitable for use in the nuclear fuel cycle and, therefore, subject to AEA safeguards control. DOE and CNEN have explored options for implementing the IAEA policy, although Brazil understands that the new policy established by the IAEA is beyond the framework of the Quadripartite Agreement of which it is one of the parties, together with Argentina, the Brazilian-Argentine Agency for Accounting and Control of Nuclear Materials, and the IAEA. This paper highlights the findings of this joint collaborative effort and identifies technical measures to strengthen international safeguards in NUCPs.« less
World Reference Center for Arboviruses.
1986-01-31
mosquitoes in Israel. Am. .1. Trop. Med. Hyg. 35:418-428, 1986. Shope, R.E. and Tesh, R.B. Rhabdovirus epidemiology. In: The Rhabdoviruses . H. Fraenkel...in the insects . Female Lu. gomezi inoculated with CoAr 170152 virus also transmitted the agent to a high percentage (80%) of their F1 offspring...12/27/75 Cowbone Ridge 8/22/68 Vesiculovirus VSV-Indiana 5/14/75 Bunyavirus Anopheles A 12/12/73 other Rhabdoviruses Anopheles B 5/30/67 Hart Park 1/16
New Nuclear Emergency Prognosis system in Korea
NASA Astrophysics Data System (ADS)
Lee, Hyun-Ha; Jeong, Seung-Young; Park, Sang-Hyun; Lee, Kwan-Hee
2016-04-01
This paper reviews the status of assessment and prognosis system for nuclear emergency response in Korea, especially atmospheric dispersion model. The Korea Institute of Nuclear Safety (KINS) performs the regulation and radiological emergency preparedness of the nuclear facilities and radiation utilizations. Also, KINS has set up the "Radiological Emergency Technical Advisory Plan" and the associated procedures such as an emergency response manual in consideration of the IAEA Safety Standards GS-R-2, GS-G-2.0, and GS-G-2.1. The Radiological Emergency Technical Advisory Center (RETAC) organized in an emergency situation provides the technical advice on radiological emergency response. The "Atomic Computerized Technical Advisory System for nuclear emergency" (AtomCARE) has been developed to implement assessment and prognosis by RETAC. KINS developed Accident Dose Assessment and Monitoring (ADAMO) system in 2015 to reflect the lessons learned from Fukushima accident. It incorporates (1) the dose assessment on the entire Korean peninsula, Asia region, and global region, (2) multi-units accident assessment (3) applying new methodology of dose rate assessment and the source term estimation with inverse modeling, (4) dose assessment and monitoring with the environmental measurements result. The ADAMO is the renovated version of current FADAS of AtomCARE. The ADAMO increases the accuracy of the radioactive material dispersion with applying the LDAPS(Local Data Assimilation Prediction System, Spatial resolution: 1.5 km) and RDAPS(Regional Data Assimilation Prediction System, Spatial resolution: 12km) of weather prediction data, and performing the data assimilation of automatic weather system (AWS) data from Korea Meteorological Administration (KMA) and data from the weather observation tower at NPP site. The prediction model of the radiological material dispersion is based on the set of the Lagrangian Particle model and Lagrangian Puff model. The dose estimation methodology incorporate the dose assessment methods of IAEA, WHO, and USNRC. The dose assessment result will express on the GIS (GIS (Geographic Information System) to provide to the local- governments and the central government. Acknowledgements This research has been supported by the Nuclear Safety and Security Commission [Reference No.1305020-0315-SB110
40 CFR 418.61 - Specialized definitions.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 30 2012-07-01 2012-07-01 false Specialized definitions. 418.61 Section 418.61 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Ammonium Sulfate Production Subcategory...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Batyukhnova, O.G.; Karlina, O.K.; Neveykin, P.P.
The International Education Training Centre (IETC) at Moscow Federal State Unitary Enterprise (FSUE) 'Radon', in co-operation with the International Atomic Energy Agency (IAEA), has developed expertise and provided training to waste management personnel for the last 15 years. Since 1997, the educational system of the enterprise with the support of the IAEA has acquired an international character: more than 470 experts from 35 countries - IAEA Member States completed the professional development. Training is conducted at various thematic courses or fellowships for individual programs and seminars on IAEA technical projects. In June 2008 a direct agreement (Practical Arrangements) has beenmore » signed between FSUE 'Radon' and the IAEA on cooperation in the field of development of new technologies, expert's advice to IAEA Member States, and, in particular, the training of personnel in the field of radioactive waste management (RWM), which opens up new perspectives for fruitful cooperation of industry professionals. A similar agreement - Practical Arrangements - has been signed between Lomonosov's MSU and the IAEA in 2012. In October 2012 a new IAEA two-weeks training course started at Lomonosov's MSU and FSUE 'Radon' in the framework of the Practical Agreements signed. Pre-disposal management of waste was the main topic of the courses. The paper summarizes the current experience of the FSUE 'Radon' in the organization and implementation of the IAEA sponsored training and others events and outlines some of strategic educational elements, which IETC will continue to pursue in the coming years. (authors)« less
48 CFR 9904.418-60 - Illustrations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Section 9904.418-60 Federal Acquisition Regulations System COST ACCOUNTING STANDARDS BOARD, OFFICE OF FEDERAL PROCUREMENT POLICY, OFFICE OF MANAGEMENT AND BUDGET PROCUREMENT PRACTICES AND COST ACCOUNTING STANDARDS COST ACCOUNTING STANDARDS 9904.418-60 Illustrations. (a) Business Unit A has various...
45 CFR 160.418 - Penalty not exclusive.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 45 Public Welfare 1 2010-10-01 2010-10-01 false Penalty not exclusive. 160.418 Section 160.418 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES ADMINISTRATIVE DATA STANDARDS AND RELATED... addition to any other penalty prescribed by law. ...
NASA Astrophysics Data System (ADS)
Wagner, Roland Josef; Schmedemann, Nico; Stephan, Katrin; Werner, Stephanie; Ivanov, Boris A.; Roatsch, Thomas; Jaumann, Ralf; Palumbo, Pasquale
2017-10-01
Crater size distributions are a valuable tool in planetary stratigraphy to derive the sequence of geologic events. In this study, we extend our previous work [1] in Ganymede’s sub-jovian hemisphere to the anti-jovian hemisphere. For geologic mapping, the map by [2] is used as a reference. Our study provides groundwork for the upcoming imaging by the JANUS camera aboard ESA’s JUICE mission [3]. Voyager-2 images are reprocessed using a map scale of 700 m/pxl achieved for parts of the anti-jovian hemisphere. To obtain relative ages from crater frequencies, we apply an updated crater scaling law for cratering into icy targets in order to derive a crater production function for Ganymede [1]. Also, we adopt the Poisson timing analysis method discussed and implemented recently [4] to obtain relative (and absolute model) ages. Results are compared to those from the sub-jovian hemisphere [1] as well as to support and/or refine the global stratigraphic system by [2]. Further emphasis is placed on local target areas in the anti-jovian hemisphere imaged by Galileo SSI at regional map scales of 100 to 300 m/pxl in order to study local geologic effects and processes. These areas incorporate (1) dark and (2) light tectonized materials, and (3) impact crater materials including an area with numerous secondaries from ray crater Osiris. References: [1] Wagner R. et al. (2014), DPS meeting #46, abstract 418.09. [2] Collins G. et al. (2013), U.S.G.S. Sci. Inv. Map 3237. [3] Della Corte V. et al. (2014), Proc. SPIE 9143, doi:10.1117/12.2056353. [4] Michael G. et al. (2016), Icarus 277, 279-285.
Nuclear Science References Database
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pritychenko, B., E-mail: pritychenko@bnl.gov; Běták, E.; Singh, B.
2014-06-15
The Nuclear Science References (NSR) database together with its associated Web interface, is the world's only comprehensive source of easily accessible low- and intermediate-energy nuclear physics bibliographic information for more than 210,000 articles since the beginning of nuclear science. The weekly-updated NSR database provides essential support for nuclear data evaluation, compilation and research activities. The principles of the database and Web application development and maintenance are described. Examples of nuclear structure, reaction and decay applications are specifically included. The complete NSR database is freely available at the websites of the National Nuclear Data Center (http://www.nndc.bnl.gov/nsr) and the International Atomic Energymore » Agency (http://www-nds.iaea.org/nsr)« less
Mora, Patricia; Blanco, Susana; Khoury, Helen; Leyton, Fernando; Cárdenas, Juan; Defaz, María Yolanda; Garay, Fernando; Telón, Flaviano; Aguilar, Juan Garcia; Roas, Norma; Gamarra, Mirtha; Blanco, Daniel; Quintero, Ana Rosa; Nader, Alejandro
2015-03-01
Latin American countries (Argentina, Brazil, Chile, Costa Rica, Cuba, Ecuador, El Salvador, Guatemala, Mexico, Nicaragua, Paraguay, Uruguay and Venezuela) working under the International Atomic Energy Agency (IAEA) Technical Cooperation Programme: TSA3 Radiological Protection of Patients in Medical Exposures have joined efforts in the optimisation of radiation protection in mammography practice. Through surveys of patient doses, the region has a unique database of diagnostic reference levels for analogue and digital equipment that will direct future optimisation activities towards the early detection of breast cancer among asymptomatic women. During RLA9/057 (2007-09) 24 institutions participated with analogue equipment in a dose survey. Regional training on methodology and measurement equipment was addressed in May 2007. The mean glandular dose (DG) was estimated using the incident kerma in air and relevant conversion coefficients for both projections craneo caudal and mediolateral oblique (CC and MLO). For Phase 2, RLA9/067 (2010-11), it was decided to include also digital systems in order to see their impact in future dose optimisation activities. Any new country that joined the project received training in the activities through IAEA expert missions. Twenty-nine new institutions participated (9 analogue and 20 digital equipment). A total of 2262 patient doses were collected during this study and from them D(G) (mGy) for both projections were estimated for each institution and country. Regional results (75 percentile in mGy) show for CC and MLO views, respectively: RLA9/057 (analogue) 2.63 and 3.17; RLA/067: 2.57 and 3.15 (analogue) and 2.69 and 2.90 (digital). Regarding only digital equipment for CC and MLO, respectively, computed radiography systems showed 2.59 and 2.78 and direct digital radiography (DDR) systems 2.78 and 3.04. Based on the IAEA Basic Safety Standard (BSS) reference dose (3 mGy), it can be observed that there is enough room to start optimisation processes in Latin America (LA); several countries or even particular institutions have values much higher than the 3 mGy. The main issues to address are lack of well-established quality assurance programmes for mammography, not enough medical physicists with training in mammography, an increase in patient doses with the introduction of digital equipment and to create awareness on radiation risk and optimisation strategies. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
10 CFR 150.17a - Compliance with requirements of US/IAEA Safeguards Agreement.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 2 2011-01-01 2011-01-01 false Compliance with requirements of US/IAEA Safeguards... Authority in Agreement States § 150.17a Compliance with requirements of US/IAEA Safeguards Agreement. (a... shall take other action as may be necessary to implement the US/IAEA Safeguards Agreement, as described...
10 CFR 150.17a - Compliance with requirements of US/IAEA Safeguards Agreement.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 2 2010-01-01 2010-01-01 false Compliance with requirements of US/IAEA Safeguards... Authority in Agreement States § 150.17a Compliance with requirements of US/IAEA Safeguards Agreement. (a... shall take other action as may be necessary to implement the US/IAEA Safeguards Agreement, as described...
Databases and coordinated research projects at the IAEA on atomic processes in plasmas
DOE Office of Scientific and Technical Information (OSTI.GOV)
Braams, Bastiaan J.; Chung, Hyun-Kyung
2012-05-25
The Atomic and Molecular Data Unit at the IAEA works with a network of national data centres to encourage and coordinate production and dissemination of fundamental data for atomic, molecular and plasma-material interaction (A+M/PMI) processes that are relevant to the realization of fusion energy. The Unit maintains numerical and bibliographical databases and has started a Wiki-style knowledge base. The Unit also contributes to A+M database interface standards and provides a search engine that offers a common interface to multiple numerical A+M/PMI databases. Coordinated Research Projects (CRPs) bring together fusion energy researchers and atomic, molecular and surface physicists for joint workmore » towards the development of new data and new methods. The databases and current CRPs on A+M/PMI processes are briefly described here.« less
Nuclear Security Objectives of an NMAC System
DOE Office of Scientific and Technical Information (OSTI.GOV)
West, Rebecca Lynn
After completing this module, you should be able to: Describe the role of Nuclear Material Accounting and Control (NMAC) in comprehensive nuclear security at a facility; Describe purpose of NMAC; Identify differences between the use of NMAC for IAEA safeguards and for facility nuclear security; List NMAC elements and measures; and Describe process for resolution of irregularities
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-21
... comment period on this information collection on May 23, 2011 (76 FR 29804). 1. Type of submission, new, revision, or extension: Extension. 2. The title of the information collection: 10 CFR Part 75, Safeguards on Nuclear Material Implementation of US/IAEA Agreement. 3. Current OMB approval number: 3150-0055. 4...
75 FR 22352 - Aviation Service Rules
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-28
... CONTACT: Tim Maguire, Mobility Division, Wireless Telecommunications Bureau, at (202) 418-2155...) 418-0530 (voice), (202) 418-0432 (TTY). 1. In this document, the Wireless Telecommunications Bureau of... wireless service providers. The SBA has developed a small business size standard for wireless firms within...
40 CFR 418.65 - Standards of performance for new sources.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 29 2014-07-01 2012-07-01 true Standards of performance for new sources. 418.65 Section 418.65 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Ammonium Sulfate...
40 CFR 418.65 - Standards of performance for new sources.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 28 2010-07-01 2010-07-01 true Standards of performance for new sources. 418.65 Section 418.65 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Ammonium Sulfate...
40 CFR 418.65 - Standards of performance for new sources.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 30 2013-07-01 2012-07-01 true Standards of performance for new sources. 418.65 Section 418.65 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Ammonium Sulfate...
40 CFR 418.65 - Standards of performance for new sources.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 29 2011-07-01 2009-07-01 true Standards of performance for new sources. 418.65 Section 418.65 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Ammonium Sulfate...
40 CFR 418.65 - Standards of performance for new sources.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 30 2012-07-01 2012-07-01 false Standards of performance for new sources. 418.65 Section 418.65 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Ammonium Sulfate...
42 CFR 418.114 - Condition of participation: Personnel qualifications.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 3 2011-10-01 2011-10-01 false Condition of participation: Personnel qualifications. 418.114 Section 418.114 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICARE PROGRAM HOSPICE CARE Conditions of participation...
40 CFR 418.10 - Applicability; description of the phosphate subcategory.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 29 2014-07-01 2012-07-01 true Applicability; description of the phosphate subcategory. 418.10 Section 418.10 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Phosphate...
40 CFR 418.10 - Applicability; description of the phosphate subcategory.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 30 2012-07-01 2012-07-01 false Applicability; description of the phosphate subcategory. 418.10 Section 418.10 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Phosphate...
40 CFR 418.10 - Applicability; description of the phosphate subcategory.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 30 2013-07-01 2012-07-01 true Applicability; description of the phosphate subcategory. 418.10 Section 418.10 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Phosphate...
42 CFR 418.114 - Condition of participation: Personnel qualifications.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 42 Public Health 3 2014-10-01 2014-10-01 false Condition of participation: Personnel qualifications. 418.114 Section 418.114 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICARE PROGRAM (CONTINUED) HOSPICE CARE Conditions of...
42 CFR 418.114 - Condition of participation: Personnel qualifications.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 42 Public Health 3 2012-10-01 2012-10-01 false Condition of participation: Personnel qualifications. 418.114 Section 418.114 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICARE PROGRAM (CONTINUED) HOSPICE CARE Conditions of...
42 CFR 418.114 - Condition of participation: Personnel qualifications.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 42 Public Health 3 2013-10-01 2013-10-01 false Condition of participation: Personnel qualifications. 418.114 Section 418.114 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICARE PROGRAM (CONTINUED) HOSPICE CARE Conditions of...
40 CFR 418.31 - Specialized definitions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 29 2011-07-01 2009-07-01 true Specialized definitions. 418.31 Section... STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Urea Subcategory § 418.31 Specialized definitions. For the purposes of this subpart: (a) Except as provided below, the general definitions, abbreviations...
47 CFR 22.537 - Technical channel assignment criteria.
Code of Federal Regulations, 2010 CFR
2010-10-01
...) 56.3 (35) 56.3 (35) (1002-1401) 428-610 32.2 (20) 37.0 (23) 41.8 (26) 56.3 (35) 56.3 (35) 56.3 (35) (1402-2001) 611-861 37.0 (23) 41.8 (26) 41.8 (26) 56.3 (35) 83.7 (52) 83.7 (52) (2002-2825) 862-1219 41.8 (26) 56.3 (35) 56.3 (35) 83.7 (52) 83.7 (52) 83.7 (52) (2826-3999) 1220+ 56.3 (35) 56.3 (35) 83.7...
NASA Astrophysics Data System (ADS)
Palmans, Hugo; Nafaa, Laila; de Patoul, Nathalie; Denis, Jean-Marc; Tomsej, Milan; Vynckier, Stefaan
2003-05-01
New codes of practice for reference dosimetry in clinical high-energy photon and electron beams have been published recently, to replace the air kerma based codes of practice that have determined the dosimetry of these beams for the past twenty years. In the present work, we compared dosimetry based on the two most widespread absorbed dose based recommendations (AAPM TG-51 and IAEA TRS-398) with two air kerma based recommendations (NCS report-5 and IAEA TRS-381). Measurements were performed in three clinical electron beam energies using two NE2571-type cylindrical chambers, two Markus-type plane-parallel chambers and two NACP-02-type plane-parallel chambers. Dosimetry based on direct calibrations of all chambers in 60Co was investigated, as well as dosimetry based on cross-calibrations of plane-parallel chambers against a cylindrical chamber in a high-energy electron beam. Furthermore, 60Co perturbation factors for plane-parallel chambers were derived. It is shown that the use of 60Co calibration factors could result in deviations of more than 2% for plane-parallel chambers between the old and new codes of practice, whereas the use of cross-calibration factors, which is the first recommendation in the new codes, reduces the differences to less than 0.8% for all situations investigated here. The results thus show that neither the chamber-to-chamber variations, nor the obtained absolute dose values are significantly altered by changing from air kerma based dosimetry to absorbed dose based dosimetry when using calibration factors obtained from the Laboratory for Standard Dosimetry, Ghent, Belgium. The values of the 60Co perturbation factor for plane-parallel chambers (katt . km for the air kerma based and pwall for the absorbed dose based codes of practice) that are obtained from comparing the results based on 60Co calibrations and cross-calibrations are within the experimental uncertainties in agreement with the results from other investigators.
Gross Alpha Beta Radioactivity in Air Filters Measured by Ultra Low Level α/β Counter
NASA Astrophysics Data System (ADS)
Cfarku, Florinda; Bylyku, Elida; Deda, Antoneta; Dhoqina, Polikron; Bakiu, Erjona; Perpunja, Flamur
2010-01-01
Study of radioactivity in air as very important for life is done regularly using different methods in every country. As a result of nuclear reactors, atomic centrals, institutions and laboratories, which use the radioactivity substances in open or closed sources, there are a lot radioactive wastes. Mixing of these wastes after treatment with rivers and lakes waters makes very important control of radioactivity. At the other side nuclear and radiological accidents are another source of the contamination of air and water. Due to their radio toxicity, especially those of Sr90, Pu239, etc. a contamination hazard for human begins exist even at low concentration levels. Measurements of radioactivity in air have been performed in many parts of the world mostly for assessment of the doses and risk resulting from consuming air. In this study we present the results of international comparison organized by IAEA Vienna, Austria for the air filters spiked with unknown Alpha and Beta Activity. For the calibration of system we used the same filters spiked: a) with Pu-239 as alpha source; b) Sr-90 as beta source and also the blank filter. The measurements of air filter samples after calibration of the system are done with Ultra Low Level α/β Counter (MPC 9604) Protean Instrument Corporation. The high sensitivity of the system for the determination of the Gross Alpha and Beta activity makes sure detection of low values activity of air filters. Our laboratory results are: Aα = (0.19±0.01) Bq/filter and Aα (IAEA) = (0.17±0.009) Bq/filter; Aβ = (0.33±0.009) Bq/filter and Aβ (IAEA) = (0.29±0.01) Bq/filter. As it seems our results are in good agreement with reference values given by IAEA (International Atomic Energy Agency).
The International Atomic Energy Agency’s Decision to Find Iran in Non-Compliance, 2002-2006
2012-12-01
Programme,” Mehr News Agency, November 14, 2004, avail- able at <www.iaea.org/newscenter/focus/iaeairan/eu_iran14112004.shtml>. 59 Shannon N. Kile , ed...www.iaea.org/newscenter/focus/iaeairan/eu_ iran14112004.shtml>. 61 Kile , 67. 62 IAEA Board Resolution, November 29, 2004, available at <www.iaea.org
Asthma in Rhinosinusitis: A Survey from Iran.
Bakhshaee, Mehdi; Majidi, Mohamad-Reza; Gharavi, Vahideh; Alavizadeh, Fatemeh-Sadat; Movahed, Rahman; Asnaashari, Parasto; Asnaashari, Amir-Mohammad-Hashem
2016-07-01
The coexistence of asthma and chronic rhinosinusitis (CRS) is more common than expected given their individual prevalence in the general population and may affect patient's quality of life. The aim of this study was to evaluate the prevalence of asthma in chronic rhinosinusitis in Mashhad, Northeast Iran. This study was performed in two university hospital from November 2012 for 12 months. In total, 153 patients with chronic rhinosinusitis were enrolled and referred to a particular pulmonologist for asthma evaluation. The mean age of participants was 40.54±13.11 years, and 41.8% were male. In total, 63.4% of patients had the polypoid form of CRS. The proportion of patients in this study with asthma was 41.8%, compared with a general asthma prevalence in this region of 13.5%. There is a high prevalence of asthma among patients with CRS, but it often remains undiagnosed. Asthma in CRS patients should be diagnosed and treated in order to improve patient's quality of life. We recommend an evaluation of the lower airways in all of these patients as well as further studies in this field.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Batyukhnova, O.G.; Karlina, O.K.; Neveikin, P.P.
The International Education Training Centre (IETC) at Moscow State Unitary Enterprise Scientific and Industrial Association 'Radon' (SIA 'Radon'), in co-operation with the International Atomic Energy Agency (IAEA), has developed expertise and provided training to waste management personnel for the last 15 years. Since 1997, the educational system of the enterprise with the support of the IAEA has acquired an international character: more than 470 experts from 35 countries- IAEA Member States completed the professional development. Training is conducted at various thematic courses or fellowships for individual programs and seminars on IAEA technical projects. In June 2008 a direct agreement (Practicalmore » Arrangements) was signed between SIA 'Radon' and the IAEA on cooperation in the field of development of new technologies, expert's advice to IAEA Member States, and, in particular, the training of personnel in the field of radioactive waste management (RWM), which opens up new perspectives for fruitful cooperation of industry professionals. The paper summarizes the current experience of the SIA 'Radon' in the organization and implementation of the IAEA sponsored training and others events and outlines some of strategic educational elements, which IETC will continue to pursue in the coming years. (authors)« less
42 CFR 418.52 - Condition of participation: Patient's rights.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 3 2011-10-01 2011-10-01 false Condition of participation: Patient's rights. 418.52 Section 418.52 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND... alleged violations involving mistreatment, neglect, or verbal, mental, sexual, and physical abuse...
42 CFR 418.52 - Condition of participation: Patient's rights.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 42 Public Health 3 2014-10-01 2014-10-01 false Condition of participation: Patient's rights. 418.52 Section 418.52 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND... alleged violations involving mistreatment, neglect, or verbal, mental, sexual, and physical abuse...
42 CFR 418.52 - Condition of participation: Patient's rights.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 42 Public Health 3 2012-10-01 2012-10-01 false Condition of participation: Patient's rights. 418.52 Section 418.52 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND... alleged violations involving mistreatment, neglect, or verbal, mental, sexual, and physical abuse...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 7 2010-10-01 2010-10-01 false Purpose. 9904.418-20... FEDERAL PROCUREMENT POLICY, OFFICE OF MANAGEMENT AND BUDGET PROCUREMENT PRACTICES AND COST ACCOUNTING STANDARDS COST ACCOUNTING STANDARDS 9904.418-20 Purpose. The purpose of this Cost Accounting Standard is to...
40 CFR 418.75 - Standards of performance for new sources.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 28 2010-07-01 2010-07-01 true Standards of performance for new sources. 418.75 Section 418.75 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Mixed and Blend Fertilizer...
40 CFR 418.75 - Standards of performance for new sources.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 30 2012-07-01 2012-07-01 false Standards of performance for new sources. 418.75 Section 418.75 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Mixed and Blend Fertilizer...
40 CFR 418.75 - Standards of performance for new sources.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 29 2011-07-01 2009-07-01 true Standards of performance for new sources. 418.75 Section 418.75 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Mixed and Blend Fertilizer...
42 CFR 418.104 - Condition of participation: Clinical records.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 3 2010-10-01 2010-10-01 false Condition of participation: Clinical records. 418.104 Section 418.104 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICARE PROGRAM HOSPICE CARE Conditions of participation: Organizational...
42 CFR 418.104 - Condition of participation: Clinical records.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 3 2011-10-01 2011-10-01 false Condition of participation: Clinical records. 418.104 Section 418.104 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICARE PROGRAM HOSPICE CARE Conditions of participation: Organizational...
42 CFR 418.102 - Condition of participation: Medical director.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 3 2011-10-01 2011-10-01 false Condition of participation: Medical director. 418.102 Section 418.102 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICARE PROGRAM HOSPICE CARE Conditions of participation: Organizational...
42 CFR 418.102 - Condition of participation: Medical director.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 3 2010-10-01 2010-10-01 false Condition of participation: Medical director. 418.102 Section 418.102 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICARE PROGRAM HOSPICE CARE Conditions of participation: Organizational...
40 CFR 418.50 - Applicability; description of the nitric acid subcategory.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 30 2012-07-01 2012-07-01 false Applicability; description of the nitric acid subcategory. 418.50 Section 418.50 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Nitric Acid...
40 CFR 418.50 - Applicability; description of the nitric acid subcategory.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 29 2014-07-01 2012-07-01 true Applicability; description of the nitric acid subcategory. 418.50 Section 418.50 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Nitric Acid...
40 CFR 418.75 - Standards of performance for new sources.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 30 2013-07-01 2012-07-01 true Standards of performance for new sources. 418.75 Section 418.75 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Mixed and Blend Fertilizer...
40 CFR 418.50 - Applicability; description of the nitric acid subcategory.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 30 2013-07-01 2012-07-01 true Applicability; description of the nitric acid subcategory. 418.50 Section 418.50 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Nitric Acid...
40 CFR 418.75 - Standards of performance for new sources.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 29 2014-07-01 2012-07-01 true Standards of performance for new sources. 418.75 Section 418.75 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Mixed and Blend Fertilizer...
40 CFR 418.50 - Applicability; description of the nitric acid subcategory.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 28 2010-07-01 2010-07-01 true Applicability; description of the nitric acid subcategory. 418.50 Section 418.50 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Nitric Acid...
40 CFR 418.50 - Applicability; description of the nitric acid subcategory.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 29 2011-07-01 2009-07-01 true Applicability; description of the nitric acid subcategory. 418.50 Section 418.50 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Nitric Acid...
47 CFR 68.418 - Procedure; designation of agents for service.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 3 2010-10-01 2010-10-01 false Procedure; designation of agents for service. 68.418 Section 68.418 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES (CONTINUED) CONNECTION OF TERMINAL EQUIPMENT TO THE TELEPHONE NETWORK Complaint Procedures § 68...
77 FR 2561 - Agency Information Collection Activities: Passenger List/Crew List (CBP Form I-418)
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-18
... use by masters, owners, or agents of vessels in complying with Sections 231 and 251 of the Immigration... I-418 can be found at http://forms.cbp.gov/pdf/CBP_Form_I418.pdf . Current Actions: This submission...
42 CFR 414.418 - Opportunity for networks.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 42 Public Health 3 2012-10-01 2012-10-01 false Opportunity for networks. 414.418 Section 414.418 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES... not supersede any Federal law or regulation that regulates anticompetitive behavior. (5) A bid...
42 CFR 414.418 - Opportunity for networks.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 42 Public Health 3 2013-10-01 2013-10-01 false Opportunity for networks. 414.418 Section 414.418 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES... not supersede any Federal law or regulation that regulates anticompetitive behavior. (5) A bid...
42 CFR 418.78 - Conditions of participation-Volunteers.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 3 2010-10-01 2010-10-01 false Conditions of participation-Volunteers. 418.78 Section 418.78 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICARE PROGRAM HOSPICE CARE Conditions of Participation: Patient Care Non-Core...
20 CFR 418.3005 - Purpose and administration of the program.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false Purpose and administration of the program. 418.3005 Section 418.3005 Employees' Benefits SOCIAL SECURITY ADMINISTRATION MEDICARE SUBSIDIES... and Human Services has responsibility for administration of the Medicare program, including the new...
TH-EF-204-02: Small Field Radiation Therapy: Physics and Recent Recommendations From IAEA and ICRU
DOE Office of Scientific and Technical Information (OSTI.GOV)
Seuntjens, J.
Joanna E. Cygler, Jan Seuntjens, J. Daniel Bourland, M. Saiful Huq, Josep Puxeu Vaque, Daniel Zucca Aparicio, Tatiana Krylova, Yuri Kirpichev, Eric Ford, Caridad Borras Stereotactic Radiation Therapy (SRT) utilizes small static and dynamic (IMRT) fields, to successfully treat malignant and benign diseases using techniques such as Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT). SRT is characterized by sharp dose gradients for individual fields and their resultant dose distributions. For appropriate targets, small field radiotherapy offers improved treatment quality by allowing better sparing of organs at risk while delivering the prescribed target dose. Specialized small field treatment deliverymore » systems, such as robotic-controlled linear accelerators, gamma radiosurgery units, and dynamic arc linear accelerators may utilize rigid fixation, image guidance, and tumor tracking, to insure precise dose delivery to static or moving targets. However, in addition to great advantages, small field delivery techniques present special technical challenges for dose calibration due to unique geometries and small field sizes not covered by existing reference dosimetry protocols such as AAPM TG-51 or IAEA TRS 398. In recent years extensive research has been performed to understand small field dosimetry and measurement instrumentation. AAPM, IAEA and ICRU task groups are expected to provide soon recommendations on the dosimetry of small radiation fields. In this symposium we will: 1] discuss the physics, instrumentation, methodologies and challenges for small field radiation dose measurements; 2] review IAEA and ICRU recommendations on prescribing, recording and reporting of small field radiation therapy; 3] discuss selected clinical applications and technical aspects for specialized image-guided, small field, linear accelerator based treatment techniques such as IMRT and SBRT. Learning Objectives: To learn the physics of small fields in contrast to dosimetry of conventional fields To learn about detectors suitable for small fields To learn about the role of Monte Carlo simulations in determination of small field output factors To provide an overview of the IAEA small field dosimetry recommendations To provide an overview of the content of the ICRU report on Prescribing, Reporting and Recording of Small Field Radiation Therapy. To learn about special technical considerations in delivering IMRT and SBRT treatments To appreciate specific challenges of IMRT implementation J. Seuntjens, Natural Sciences and Engineering Research Council; Canadian Institutes of Health Research.« less