Sample records for reference material production

  1. Recent developments in the field of environmental reference materials at the JRC Ispra.

    PubMed

    Muntau, H

    2001-06-01

    The production of reference materials for environmental analysis started in the Joint Research Centre at Ispra/Italy in 1972 with the objective of later certification by the BCR, but for obvious budget reasons only a fraction of the total production achieved at Ispra ever reached certification level, although all materials were produced according to the severe quality requirements requested for certified reference materials. Therefore, the materials not destinated to certification are in growing demand as inter-laboratory test materials and as laboratory reference materials, for internal quality control, e.g., by control charts. The history of reference material production within the Joint Research Centre is briefly reviewed and the latest additions described. New developments such as micro-scale reference materials intended for analytical methods requiring sample intakes at milligram or sub-milligram level and therefor not finding supply on the reference material market, and "wet" environmental reference materials, which meet more precisely the "real-world" environmental analysis conditions, are presented and the state-of-the-art discussed.

  2. Devices for the Production of Reference Gas Mixtures.

    PubMed

    Fijało, Cyprian; Dymerski, Tomasz; Gębicki, Jacek; Namieśnik, Jacek

    2016-09-02

    For many years there has been growing demand for gaseous reference materials, which is connected with development in many fields of science and technology. As a result, new methodological and instrumental solutions appear that can be used for this purpose. Appropriate quality assurance/quality control (QA/QC) must be used to make sure that measurement data are a reliable source of information. Reference materials are a significant element of such systems. In the case of gas samples, such materials are generally called reference gas mixtures. This article presents the application and classification of reference gas mixtures, which are a specific type of reference materials, and the methods for obtaining them are described. Construction solutions of devices for the production of reference gas mixtures are detailed, and a description of a prototype device for dynamic production of reference gas mixtures containing aroma compounds is presented.

  3. BIOBASED MATERIALS

    EPA Science Inventory

    Biobased materials refer to products that mainly consist of a substance (or substances) derived from living matter (biomass) and either occur naturally or are synthesized, or it may refer to products made by processes that use biomass. Following a strict definition, many common m...

  4. [Development and application of reference materials containing mixed degradation products of amoxicillin and ampicillin].

    PubMed

    Li, Wei; Zhang, Wei-Qing; Li, Xiang; Hu, Chang-Qin

    2014-09-01

    Reference materials containing mixed degradation products of amoxicillin and ampicillin were developed after optimization of preparation processes. The target impurities were obtained by controlled stress testing, and each major component was identified with HPLC-MS and compared with single traceable reference standard each. The developed reference materials were applied to system suitability test for verifying HPLC system performed in accordance with set forth in China Pharmacopeia and identification of major impurities in samples based on retention and spectra information, which have advantages over the methods put forth in foreign pharmacopoeias. The development and application of the reference materials offer an effective way for rapid identification of impurities in chromatograms, and provide references for analyzing source of impurities and evaluation of drug quality.

  5. Critical outlook and trends for environmental reference materials at the Measurements & Testing Generic Activity (European Commission).

    PubMed

    Quevauviller, P; Bennink, D; Bøwadt, S

    2001-05-01

    It is now well recognised that the quality control (QC) of all types of analyses, including environmental analyses depends on the appropriate use of reference materials. One of the ways to check the accuracy of methods is based on the use of Certified Reference Materials (CRMs), whereas other types of (not certified) Reference Materials (RMs) are used for routine quality control (establishment of control charts) and interlaboratory testing (e.g. proficiency testing). The perception of these materials, in particular with respect to their production and use, differs widely according to various perspectives (e.g. RM producers, routine laboratories, researchers). This review discusses some critical aspects of RM use and production for the QC of environmental analyses and describes the new approach followed by the Measurements & Testing Generic Activity (European Commission) to tackle new research and production needs.

  6. Diffusion-controlled reference material for VOC emissions testing: proof of concept.

    PubMed

    Cox, S S; Liu, Z; Little, J C; Howard-Reed, C; Nabinger, S J; Persily, A

    2010-10-01

    Because of concerns about indoor air quality, there is growing awareness of the need to reduce the rate at which indoor materials and products emit volatile organic compounds (VOCs). To meet consumer demand for low emitting products, manufacturers are increasingly submitting materials to independent laboratories for emissions testing. However, the same product tested by different laboratories can result in very different emissions profiles because of a general lack of test validation procedures. There is a need for a reference material that can be used as a known emissions source and that will have the same emission rate when tested by different laboratories under the same conditions. A reference material was created by loading toluene into a polymethyl pentene film. A fundamental emissions model was used to predict the toluene emissions profile. Measured VOC emissions profiles using small-chamber emissions tests compared reasonably well to the emissions profile predicted using the emissions model, demonstrating the feasibility of the proposed approach to create a diffusion-controlled reference material. To calibrate emissions test chambers and improve the reproducibility of VOC emission measurements among different laboratories, a reference material has been created using a polymer film loaded with a representative VOC. Initial results show that the film's VOC emission profile measured in a conventional test chamber compares well to predictions based on independently determined material/chemical properties and a fundamental emissions model. The use of such reference materials has the potential to build consensus and confidence in emissions testing as well as 'level the playing field' for product testing laboratories and manufacturers.

  7. Reference Materials: Significance, General Requirements, and Demand.

    PubMed

    Kiełbasa, Anna; Gadzała-Kopciuch, Renata; Buszewski, Bogusław

    2016-05-03

    Reference materials play an important part in the quality control of measurements. Rapid development of such new scientific disciplines as proteomics, metabolomics, and genomics also necessitates development of new reference materials. This is a great challenge due to the complexity of the production of new reference materials and difficulties associated with achieving their homogeneity and stability. CRMs of tissue are of particular importance. They can be counted among the matrices that are most complex and time consuming in preparation. Tissue is the place of transformation and accumulation of many substances (e.g., metabolites, which are intermediate or end products resulting from metabolic processes). Trace amounts of many substances in tissues must be determined with adequate precision and accuracy. To meet the needs stemming from research and from problems and challenges faced by chemists, analysts, and toxicologists, the number of certified reference materials should be continuously increased.

  8. 40 CFR 89.6 - Reference materials.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... set forth the material that has been incorporated by reference in this part. (1) ASTM material. The... 19428-2959. Document number and name 40 CFR part 89 reference ASTM D86-97: “Standard Test Method for Distillation of Petroleum Products at Atmospheric Pressure” Appendix A to Subpart D. ASTM D93-97: “Standard...

  9. 21 CFR 320.27 - Guidelines on the design of a multiple-dose in vivo bioavailability study.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ..., DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS FOR HUMAN USE BIOAVAILABILITY AND BIOEQUIVALENCE... therapeutic moiety in the body. (2) The test product and the reference material should be administered to...) Measurement of an acute pharmacological effect. When comparison of the test product and the reference material...

  10. 21 CFR 320.27 - Guidelines on the design of a multiple-dose in vivo bioavailability study.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ..., DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS FOR HUMAN USE BIOAVAILABILITY AND BIOEQUIVALENCE... therapeutic moiety in the body. (2) The test product and the reference material should be administered to...) Measurement of an acute pharmacological effect. When comparison of the test product and the reference material...

  11. 21 CFR 320.27 - Guidelines on the design of a multiple-dose in vivo bioavailability study.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ..., DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS FOR HUMAN USE BIOAVAILABILITY AND BIOEQUIVALENCE... therapeutic moiety in the body. (2) The test product and the reference material should be administered to...) Measurement of an acute pharmacological effect. When comparison of the test product and the reference material...

  12. Advertising content in physical activity print materials.

    PubMed

    Cardinal, Bradley J

    2002-01-01

    Copies of 80 sets of print materials available free of charge to the general public were analyzed to determine the relationship between the developer and advertising-related material. Almost all of the materials had some form of advertising content. Materials from commercial product vendors were most likely to have product logos, references to specific brands, and had the greatest number of logos, and the greatest number of references to specific brands. They were the second most likely to have advertising slogans, and had the second greatest number of advertising slogans.

  13. 40 CFR 94.5 - Reference materials.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    .../code_of_federal_regulations/ibr_locations.html. (a) ASTM material. Table 1 of § 94.5 lists material... of § 94.5—ASTM Materials Document No. and name Part 94 reference ASTM D 86-01, Standard Test Method for Distillation of Petroleum Products at Atmospheric Pressure 94.108 ASTM D 93-02, Standard Test...

  14. 21 CFR 211.194 - Laboratory records.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... specific component, drug product container, closure, in-process material, or drug product, and lot tested... product container, closure, in-process material, or drug product tested. (7) The initials or signature of... of any testing and standardization of laboratory reference standards, reagents, and standard...

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Byerly, Benjamin L.; Stanley, Floyd; Spencer, Khal

    In our study, a certified plutonium metal reference material (CRM 126) with a known production history is examined using analytical methods that are commonly employed in nuclear forensics for provenancing and attribution. Moreover, the measured plutonium isotopic composition and actinide assay are consistent with values reported on the reference material certificate. Model ages from U/Pu and Am/Pu chronometers agree with the documented production timeline. Finally, these results confirm the utility of these analytical methods and highlight the importance of a holistic approach for forensic study of unknown materials.

  16. 40 CFR 92.5 - Reference materials.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...: (1) ASTM material. The following table sets forth material from the American Society for Testing and...., Philadelphia, PA 19103. The table follows: Document number and name 40 CFR part 92 reference ASTM D 86-95, Standard Test Method for Distillation of Petroleum Products § 92.113 ASTM D 93-94, Standard Test Methods...

  17. Development of candidate reference materials for the measurement of lead in bone

    PubMed Central

    Hetter, Katherine M.; Bellis, David J.; Geraghty, Ciaran; Todd, Andrew C.; Parsons, Patrick J.

    2010-01-01

    The production of modest quantities of candidate bone lead (Pb) reference materials is described, and an optimized production procedure is presented. The reference materials were developed to enable an assessment of the interlaboratory agreement of laboratories measuring Pb in bone; method validation; and for calibration of solid sampling techniques such as laser ablation ICP-MS. Long bones obtained from Pb-dosed and undosed animals were selected to produce four different pools of a candidate powdered bone reference material. The Pb concentrations of these pools reflect both environmental and occupational exposure levels in humans. The animal bones were harvested post mortem, cleaned, defatted, and broken into pieces using the brittle fracture technique at liquid nitrogen temperature. The bone pieces were then ground in a knife mill to produce fragments of 2-mm size. These were further ground in an ultra-centrifugal mill, resulting in finely powdered bone material that was homogenized and then sampled-scooped into vials. Testing for contamination and homogeneity was performed via instrumental methods of analysis. PMID:18421443

  18. USGS reference materials

    USGS Publications Warehouse

    ,

    1995-01-01

    Every year in the United States, millions of measurements are made on the chemical composition of items that affect us on a daily basis. Determining the accuracy of these measurements is based on the analysis of appropriate reference materials whose composition was previously determined through rigorous testing. Today, reference materials help us evaluate the composition of the food we eat, medicine we use, soil we grow our crops in, and hundreds of other products that affect our everyday lives.

  19. 9 CFR 77.1 - Material incorporated by reference.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... AGRICULTURE INTERSTATE TRANSPORTATION OF ANIMALS (INCLUDING POULTRY) AND ANIMAL PRODUCTS TUBERCULOSIS General Provisions § 77.1 Material incorporated by reference. Uniform Methods and Rules—Bovine Tuberculosis Eradication. The Uniform Methods and Rules—Bovine Tuberculosis Eradication (January 22, 1999, edition) has...

  20. 9 CFR 77.1 - Material incorporated by reference.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... AGRICULTURE INTERSTATE TRANSPORTATION OF ANIMALS (INCLUDING POULTRY) AND ANIMAL PRODUCTS TUBERCULOSIS General Provisions § 77.1 Material incorporated by reference. Uniform Methods and Rules—Bovine Tuberculosis Eradication. The Uniform Methods and Rules—Bovine Tuberculosis Eradication (January 22, 1999, edition) has...

  1. 9 CFR 77.1 - Material incorporated by reference.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... AGRICULTURE INTERSTATE TRANSPORTATION OF ANIMALS (INCLUDING POULTRY) AND ANIMAL PRODUCTS TUBERCULOSIS General Provisions § 77.1 Material incorporated by reference. Uniform Methods and Rules—Bovine Tuberculosis Eradication. The Uniform Methods and Rules—Bovine Tuberculosis Eradication (January 22, 1999, edition) has...

  2. 9 CFR 77.1 - Material incorporated by reference.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... AGRICULTURE INTERSTATE TRANSPORTATION OF ANIMALS (INCLUDING POULTRY) AND ANIMAL PRODUCTS TUBERCULOSIS General Provisions § 77.1 Material incorporated by reference. Uniform Methods and Rules—Bovine Tuberculosis Eradication. The Uniform Methods and Rules—Bovine Tuberculosis Eradication (January 22, 1999, edition) has...

  3. 9 CFR 77.1 - Material incorporated by reference.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... AGRICULTURE INTERSTATE TRANSPORTATION OF ANIMALS (INCLUDING POULTRY) AND ANIMAL PRODUCTS TUBERCULOSIS General Provisions § 77.1 Material incorporated by reference. Uniform Methods and Rules—Bovine Tuberculosis Eradication. The Uniform Methods and Rules—Bovine Tuberculosis Eradication (January 22, 1999, edition) has...

  4. Forensic investigation of plutonium metal: a case study of CRM 126

    DOE PAGES

    Byerly, Benjamin L.; Stanley, Floyd; Spencer, Khal; ...

    2016-11-01

    In our study, a certified plutonium metal reference material (CRM 126) with a known production history is examined using analytical methods that are commonly employed in nuclear forensics for provenancing and attribution. Moreover, the measured plutonium isotopic composition and actinide assay are consistent with values reported on the reference material certificate. Model ages from U/Pu and Am/Pu chronometers agree with the documented production timeline. Finally, these results confirm the utility of these analytical methods and highlight the importance of a holistic approach for forensic study of unknown materials.

  5. 40 CFR 432.5 - Incorporation by reference.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... AND STANDARDS MEAT AND POULTRY PRODUCTS POINT SOURCE CATEGORY § 432.5 Incorporation by reference. (a... Federal Register. The material is available for purchase at the address in paragraph (b) of this section..., Washington, DC. (b) The following material is available for purchase from the National Technical Information...

  6. Development of benzene, toluene, ethylbenzene and xylenes certified gaseous reference materials

    NASA Astrophysics Data System (ADS)

    Brum, M. C.; Sobrinho, D. C. G.; Fagundes, F. A.; Oudwater, R. J.; Augusto, C. R.

    2016-07-01

    The work describes the production of certified gaseous reference materials of benzene, toluene, ethylbenzene and xylenes (BTEX) in nitrogen from the gravimetric production up to the long term stability tests followed by the certifying step. The uncertainty in the amount fractions of the compounds in these mixtures was approximately 4% (relative) for the range studied from 2 to 16 µmol/mol. Also the adsorption of the BTEX on the cylinder surface and the tubing were investigated as potential uncertainty source.

  7. Certification of elements in and use of standard reference material 3280 multivitamin/multielement tablets.

    PubMed

    Turk, Gregory C; Sharpless, Katherine E; Cleveland, Danielle; Jongsma, Candice; Mackey, Elizabeth A; Marlow, Anthony F; Oflaz, Rabia; Paul, Rick L; Sieber, John R; Thompson, Robert Q; Wood, Laura J; Yu, Lee L; Zeisler, Rolf; Wise, Stephen A; Yen, James H; Christopher, Steven J; Day, Russell D; Long, Stephen E; Greene, Ella; Harnly, James; Ho, I-Pin; Betz, Joseph M

    2013-01-01

    Standard Reference Material 3280 Multivitamin/ Multielement Tablets was issued by the National Institute of Standards and Technology in 2009, and has certified and reference mass fraction values for 13 vitamins, 26 elements, and two carotenoids. Elements were measured using two or more analytical methods at NIST with additional data contributed by collaborating laboratories. This reference material is expected to serve a dual purpose: to provide quality assurance in support of a database of dietary supplement products and to provide a means for analysts, dietary supplement manufacturers, and researchers to assess the appropriateness and validity of their analytical methods and the accuracy of their results.

  8. The importance of reference materials in doping-control analysis.

    PubMed

    Mackay, Lindsey G; Kazlauskas, Rymantas

    2011-08-01

    Currently a large range of pure substance reference materials are available for calibration of doping-control methods. These materials enable traceability to the International System of Units (SI) for the results generated by World Anti-Doping Agency (WADA)-accredited laboratories. Only a small number of prohibited substances have threshold limits for which quantification is highly important. For these analytes only the highest quality reference materials that are available should be used. Many prohibited substances have no threshold limits and reference materials provide essential identity confirmation. For these reference materials the correct identity is critical and the methods used to assess identity in these cases should be critically evaluated. There is still a lack of certified matrix reference materials to support many aspects of doping analysis. However, in key areas a range of urine matrix materials have been produced for substances with threshold limits, for example 19-norandrosterone and testosterone/epitestosterone (T/E) ratio. These matrix-certified reference materials (CRMs) are an excellent independent means of checking method recovery and bias and will typically be used in method validation and then regularly as quality-control checks. They can be particularly important in the analysis of samples close to threshold limits, in which measurement accuracy becomes critical. Some reference materials for isotope ratio mass spectrometry (IRMS) analysis are available and a matrix material certified for steroid delta values is currently under production. In other new areas, for example the Athlete Biological Passport, peptide hormone testing, designer steroids, and gene doping, reference material needs still need to be thoroughly assessed and prioritised.

  9. The NIH analytical methods and reference materials program for dietary supplements.

    PubMed

    Betz, Joseph M; Fisher, Kenneth D; Saldanha, Leila G; Coates, Paul M

    2007-09-01

    Quality of botanical products is a great uncertainty that consumers, clinicians, regulators, and researchers face. Definitions of quality abound, and include specifications for sanitation, adventitious agents (pesticides, metals, weeds), and content of natural chemicals. Because dietary supplements (DS) are often complex mixtures, they pose analytical challenges and method validation may be difficult. In response to product quality concerns and the need for validated and publicly available methods for DS analysis, the US Congress directed the Office of Dietary Supplements (ODS) at the National Institutes of Health (NIH) to accelerate an ongoing methods validation process, and the Dietary Supplements Methods and Reference Materials Program was created. The program was constructed from stakeholder input and incorporates several federal procurement and granting mechanisms in a coordinated and interlocking framework. The framework facilitates validation of analytical methods, analytical standards, and reference materials.

  10. Household Hazardous Materials and Their Labels: A Reference for Teachers.

    ERIC Educational Resources Information Center

    Dean, Lillian F.

    Household hazardous materials are products or wastes which are toxic, corrosive, reactive, and/or ignitable. Although common products such as pesticides, oils, gasoline, solvents, cleaners, and polishes are hazardous, students and adults are not always aware of potential dangers. This sourcebook contains definitions and examples of household…

  11. Food Production, Management, and Services. Baking. Teacher Edition. Second Edition.

    ERIC Educational Resources Information Center

    Gibson, LeRoy

    These instructional materials are intended for a course on food production, management, and services involved in baking. The following introductory information is included: use of this publication; competency profile; instructional/task analysis; related academic and workplace skills list; tools, materials, and equipment list; 13 references; and a…

  12. Validation of reference materials for uranium radiochronometry in the frame of nuclear forensic investigations

    DOE PAGES

    Varga, Z.; Mayer, K.; Bonamici, C. E.; ...

    2015-05-11

    The results of a joint effort by expert nuclear forensic laboratories in the area of age dating of uranium, i.e. the elapsed time since the last chemical purification of the material are presented and discussed. Completely separated uranium materials of known production date were distributed among the laboratories, and the samples were dated according to routine laboratory procedures by the measurement of the ²²⁰Th/²³⁴U ratio. The measurement results were in good agreement with the known production date showing that the concept for preparing uranium age dating reference material based on complete separation is valid. Detailed knowledge of the laboratory proceduresmore » used for uranium age dating allows the identification of possible improvements in the current protocols and the development of improved practice in the future. The availability of age dating reference materials as well as the evolvement of the age dating best-practice protocol will increase the relevance and applicability of age dating as part of the tool-kit available for nuclear forensic investigations.« less

  13. Validation of reference materials for uranium radiochronometry in the frame of nuclear forensic investigations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Varga, Z.; Mayer, K.; Bonamici, C. E.

    The results of a joint effort by expert nuclear forensic laboratories in the area of age dating of uranium, i.e. the elapsed time since the last chemical purification of the material are presented and discussed. Completely separated uranium materials of known production date were distributed among the laboratories, and the samples were dated according to routine laboratory procedures by the measurement of the ²²⁰Th/²³⁴U ratio. The measurement results were in good agreement with the known production date showing that the concept for preparing uranium age dating reference material based on complete separation is valid. Detailed knowledge of the laboratory proceduresmore » used for uranium age dating allows the identification of possible improvements in the current protocols and the development of improved practice in the future. The availability of age dating reference materials as well as the evolvement of the age dating best-practice protocol will increase the relevance and applicability of age dating as part of the tool-kit available for nuclear forensic investigations.« less

  14. The production and certification of a plutonium equal-atom reference material: NBL CRM 128

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Crawford, D.W.; Gradle, C.G.; Soriano, M.D.

    This report describes the design, production, and certification of the New Brunswick Laboratory plutonium equal-atom certified reference material (CRM), NBL CRM 128. The primary use of this CRM is for the determination of bias corrections encountered in the operation of a mass spectrometer. This reference material is available to the US Department of Energy contractor-operated and government-operated laboratories, as well as to the international nuclear safeguards community. The absolute, or unbiased, certified value for the CRM's Pu-242/Pu-239 ratio is 1.00063 {plus minus} 0.00026 (95% confidence interval) as of October 1, 1984. This value was obtained through the quantitative blending ofmore » high-purity, chemically and isotopically characterized separated isotopes, as well as through intercomparisons of CRM samples with calibration mixtures using thermal ionization mass spectrometry. 32 tabs.« less

  15. [Effect of emotional content and self reference of learning materials on recall performance].

    PubMed

    Spies, K

    1994-01-01

    It is assumed that high affective value and high self-reference of learning material help to improve memory performance as these factors allow better memory consolidation (activation hypothesis) or better integration of the new material into existing knowledge structures (extent-of-processing hypothesis). To test this assumption, 60 subjects were shown 16 short advertising films characterized by low vs. high affective value and low vs. high self-reference. Both factors were varied within subjects. After the films had each been presented twice, subjects had to recall the product names and answer two questions to each film. Results showed for both dependent variables that films with high affective values were better remembered than films with low affective values. The same held true--though to a lower extent--with respect to self-reference. According to the expected linear trend, performance was best for material scoring high on affective value as well as on self-reference, while it was worst for material scoring low on both factors.

  16. 230Th-234U Model-Ages of Some Uranium Standard Reference Materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Williams, R W; Gaffney, A M; Kristo, M J

    The 'age' of a sample of uranium is an important aspect of a nuclear forensic investigation and of the attribution of the material to its source. To the extent that the sample obeys the standard rules of radiochronometry, then the production ages of even very recent material can be determined using the {sup 230}Th-{sup 234}U chronometer. These standard rules may be summarized as (a) the daughter/parent ratio at time=zero must be known, and (b) there has been no daughter/parent fractionation since production. For most samples of uranium, the 'ages' determined using this chronometer are semantically 'model-ages' because (a) some assumptionmore » of the initial {sup 230}Th content in the sample is required and (b) closed-system behavior is assumed. The uranium standard reference materials originally prepared and distributed by the former US National Bureau of Standards and now distributed by New Brunswick Laboratory as certified reference materials (NBS SRM = NBL CRM) are good candidates for samples where both rules are met. The U isotopic standards have known purification and production dates, and closed-system behavior in the solid form (U{sub 3}O{sub 8}) may be assumed with confidence. We present here {sup 230}Th-{sup 234}U model-ages for several of these standards, determined by isotope dilution mass spectrometry using a multicollector ICP-MS, and compare these ages with their known production history.« less

  17. Historical Zinc Smelting in New Jersey, Pennsylvania, Virginia, West Virginia, and Washington, D.C., with Estimates of Atmospheric Zinc Emissions and Other Materials

    USGS Publications Warehouse

    Bleiwas, Donald I.; DiFrancesco, Carl

    2010-01-01

    The metallurgical industry can be broadly divided into metal production from feedstock consisting of primary and secondary sources. Primary production refers to the extraction of metal derived from ores and concentrates. Secondary production refers to the recovery of metal from materials such as alloys, electric arc furnace dust, ingots, and scrap. The foci of this study are the histories of selected pyrometallurgical plants that treated mostly primary zinc feedstock and the atmospheric emissions, primarily zinc, generated by those plants during the course of producing zinc and zinc oxide in New Jersey, Pennsylvania, Virginia, West Virginia, and Washington, D.C.

  18. POTENTIAL RADIOACTIVE POLLUTANTS RESULTING FROM EXPANDED ENERGY PROGRAMS

    EPA Science Inventory

    An effective environmental monitoring program must have a quality assurance component to assure the production of valid data. Quality assurance has many components: calibration standards, standard reference materials, standard reference methods, interlaboratory comparison studies...

  19. Products to Aid in Daily Living

    MedlinePlus

    ... not assume any responsibility or liability for any communication or materials available at such linked sites. Any reference to a commercial or noncommercial product, process, service or company is ...

  20. Inreach: The Inside Step to Outreach

    ERIC Educational Resources Information Center

    Germain, Carol Anne

    2006-01-01

    After undertaking the time and energy consuming task of reference assessment, the library might discover that it needs to tweak delivery of service, weed and update the collection, upgrade workstations, or advance marketing strategies to get patrons to use reference materials and services. Like any other product or service, reference departments…

  1. DEVELOPMENT OF CONTINUOUS SOLVENT EXTRACTION PROCESSES FOR COAL DERIVED CARBON PRODUCTS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Elliot B. Kennel; Stephen P. Carpenter; Dady Dadyburjor

    2006-03-27

    The purpose of this DOE-funded effort is to develop continuous processes for solvent extraction of coal for the production of carbon products. These carbon products include materials used in metals smelting, especially in the aluminum and steel industries, as well as porous carbon structural material referred to as ''carbon foam'' and carbon fibers. During this reporting period, efforts have focused on the development of continuous processes for hydrogenation as well as continuous production of carbon foam and coke.

  2. Development of potential candidate reference materials for drugs in bottom sediment, cod and herring tissues.

    PubMed

    Baranowska, Irena; Buszewski, Bogusław; Namieśnik, Jacek; Konieczka, Piotr; Magiera, Sylwia; Polkowska-Motrenko, Halina; Kościelniak, Paweł; Gadzała-Kopciuch, Renata; Woźniakiewicz, Aneta; Samczyński, Zbigniew; Kochańska, Kinga; Rutkowska, Małgorzata

    2017-02-01

    Regular use of a reference material and participation in a proficiency testing program can improve the reliability of analytical data. This paper presents the preparation of candidate reference materials for the drugs metoprolol, propranolol, carbamazepine, naproxen, and acenocoumarol in freshwater bottom sediment and cod and herring tissues. These reference materials are not available commercially. Drugs (between 7 ng/g and 32 ng/g) were added to the samples, and the spiked samples were freeze-dried, pulverized, sieved, homogenized, bottled, and sterilized by γ-irradiation to prepare the candidate materials. Procedures for extraction and liquid chromatography coupled with tandem mass spectrometry were developed to determine the drugs of interest in the studied material. Each target drug was quantified using two analytical procedures, and the results obtained from these two procedures were in good agreement with each other. Stability and homogeneity assessments were performed, and the relative uncertainties due to instability (for an expiration date of 12 months) and inhomogeneity were 10-25% and 4.0-6.8%, respectively. These procedures will be useful in the future production of reference materials. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Future Directions for Selected Topics in Physics and Materials Science

    DTIC Science & Technology

    2012-07-12

    referred to as lightides (e.g. borides , nitrides, phosphides) • Materials for energy conversion, energy storage, energy transport and energy production...Distributed nanosystems and sensors • Strategy for multilayered combinatorics • lightides ( borides , nitrides, phosphides, • New applications for...Strategy for multilayered combinatorics Lightides ( borides , nitrides, phosphides) • Energy conversion, .storage and production • Precision control

  4. Quantitative Technique for Comparing Simulant Materials through Figures of Merit

    NASA Technical Reports Server (NTRS)

    Rickman, Doug; Hoelzer, Hans; Fourroux, Kathy; Owens, Charles; McLemore, Carole; Fikes, John

    2007-01-01

    The 1989 workshop report entitled Workshop on Production and Uses of Simulated Lunar Materials and the Lunar Regolith Simulant Materials: Recommendations for Standardization, Production, and Usage, NASA Technical Publication both identified and reinforced a need for a set of standards and requirements for the production and usage of the Lunar simulant materials. As NASA prepares to return to the Moon, and set out to Mars, a set of early requirements have been developed for simulant materials and the initial methods to produce and measure those simulants have been defined. Addressed in the requirements document are: 1) a method for evaluating the quality of any simulant of a regolith, 2) the minimum characteristics for simulants of Lunar regolith, and 3) a method to produce simulants needed for NASA's Exploration mission. As an extension of the requirements document a method to evaluate new and current simulants has been rigorously defined through the mathematics of Figures of Merit (FoM). Requirements and techniques have been developed that allow the simulant provider to compare their product to a standard reference material through Figures of Merit. Standard reference material may be physical material such as the Apollo core samples or material properties predicted for any landing site. The simulant provider is not restricted to providing a single "high fidelity" simulant, which may be costly to produce. The provider can now develop "lower fidelity" simulants for engineering applications such as drilling and mobility applications.

  5. Workshop on Using In Situ Resources for Construction of Planetary Outposts

    NASA Technical Reports Server (NTRS)

    Duke, Michael B. (Editor)

    1998-01-01

    The workshop examined the potential uses of indigenous materials on the Moon and Mars, other than those associated with the production of propellants for space transportation. The papers presented concerned the needs for construction, based on analysis of the current NASA Mars reference Mission and past studies studies of lunar outposts; the availability of materials on the Moon and Mars; construction techniques that make use of the natural environment; materials production and fabrication techniques based on indigenous materials; and new technologies that could promote the use of indigenous materials in construction.

  6. 76 FR 15901 - Acquisition Regulation Miscellaneous Changes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-22

    ... obsolete material is being removed. DATES: Submit comments by May 23, 2011. ADDRESSES: You may submit... order to update references to other federal and Departmental directives, remove obsolete material and... efficient and transparent. This rule will not adversely affect in a material way the economy, productivity...

  7. Practical fundamentals of glass, rubber, and plastic sterile packaging systems.

    PubMed

    Sacha, Gregory A; Saffell-Clemmer, Wendy; Abram, Karen; Akers, Michael J

    2010-01-01

    Sterile product packaging systems consist of glass, rubber, and plastic materials that are in intimate contact with the formulation. These materials can significantly affect the stability of the formulation. The interaction between the packaging materials and the formulation can also affect the appropriate delivery of the product. Therefore, a parenteral formulation actually consists of the packaging system as well as the product that it contains. However, the majority of formulation development time only considers the product that is contained in the packaging system. Little time is spent studying the interaction of the packaging materials with the contents. Interaction between the packaging and the contents only becomes a concern when problems are encountered. For this reason, there are few scientific publications that describe the available packaging materials, their advantages and disadvantages, and their important product attributes. This article was created as a reference for product development and describes some of the packaging materials and systems that are available for parenteral products.

  8. DEVELOPMENT OF CONTINUOUS SOLVENT EXTRACTION PROCESSES FOR COAL DERIVED CARBON PRODUCTS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Elliot B. Kennel; Chong Chen; Dady Dadyburjor

    2005-04-13

    The purpose of this DOE-funded effort is to develop continuous processes for solvent extraction of coal for the production of carbon products. These carbon products include materials used in metals smelting, especially in the aluminum and steel industries, as well as porous carbon structural material referred to as ''carbon foam'' and carbon fibers. Table 1 provides an overview of the major markets for carbon products. Current sources of materials for these processes generally rely on petroleum distillation products or coal tar distillates obtained as a byproduct of metcoke production facilities. In the former case, the American materials industry, just asmore » the energy industry, is dependent upon foreign sources of petroleum. In the latter case, metcoke production is decreasing every year due to the combined difficulties associated with poor economics and a significant environmental burden. Thus, a significant need exists for an environmentally clean process which can used domestically obtained raw materials and which can still be very competitive economically.« less

  9. Characterization of NIST food-matrix Standard Reference Materials for their vitamin C content.

    PubMed

    Thomas, Jeanice B; Yen, James H; Sharpless, Katherine E

    2013-05-01

    The vitamin C concentrations in three food-matrix Standard Reference Materials (SRMs) from the National Institute of Standards and Technology (NIST) have been determined by liquid chromatography (LC) with absorbance detection. These materials (SRM 1549a Whole Milk Powder, SRM 1849a Infant/Adult Nutritional Formula, and SRM 3233 Fortified Breakfast Cereal) have been characterized to support analytical measurements made by food processors that are required to provide information about their products' vitamin C content on the labels of products distributed in the United States. The SRMs are primarily intended for use in validating analytical methods for the determination of selected vitamins, elements, fatty acids, and other nutrients in these materials and in similar matrixes. They can also be used for quality assurance in the characterization of test samples or in-house control materials, and for establishing measurement traceability. Within-day precision of the LC method used to measure vitamin C in the food-matrix SRMs characterized in this study ranged from 2.7% to 6.5%.

  10. Development of a reference material of a single DNA molecule for the quality control of PCR testing.

    PubMed

    Mano, Junichi; Hatano, Shuko; Futo, Satoshi; Yoshii, Junji; Nakae, Hiroki; Naito, Shigehiro; Takabatake, Reona; Kitta, Kazumi

    2014-09-02

    We developed a reference material of a single DNA molecule with a specific nucleotide sequence. The double-strand linear DNA which has PCR target sequences at the both ends was prepared as a reference DNA molecule, and we named the PCR targets on each side as confirmation sequence and standard sequence. The highly diluted solution of the reference molecule was dispensed into 96 wells of a plastic PCR plate to make the average number of molecules in a well below one. Subsequently, the presence or absence of the reference molecule in each well was checked by real-time PCR targeting for the confirmation sequence. After an enzymatic treatment of the reaction mixture in the positive wells for the digestion of PCR products, the resultant solution was used as the reference material of a single DNA molecule with the standard sequence. PCR analyses revealed that the prepared samples included only one reference molecule with high probability. The single-molecule reference material developed in this study will be useful for the absolute evaluation of a detection limit of PCR-based testing methods, the quality control of PCR analyses, performance evaluations of PCR reagents and instruments, and the preparation of an accurate calibration curve for real-time PCR quantitation.

  11. 30 CFR 250.198 - Documents incorporated by reference.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (Identical), Petroleum and natural gas industries—Pipeline transportation systems—Pipeline valves; Product No... GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF General References § 250.198 Documents... Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to...

  12. 10 CFR 431.303 - Materials incorporated by reference.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ...-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus, approved May 1, 2004..., (“DIN EN 13164”), Thermal insulation products for buildings—Factory made products of extruded... 431. (2) DIN EN 13165:2009-02, (“DIN EN 13165”), Thermal insulation products for buildings—Factory...

  13. 10 CFR 431.303 - Materials incorporated by reference.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ...-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus, approved May 1, 2004..., (“DIN EN 13164”), Thermal insulation products for buildings—Factory made products of extruded... 431. (2) DIN EN 13165:2009-02, (“DIN EN 13165”), Thermal insulation products for buildings—Factory...

  14. 10 CFR 431.303 - Materials incorporated by reference.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Transmission Properties by Means of the Heat Flow Meter Apparatus, approved May 1, 2004, IBR approved for § 431... insulation products for buildings—Factory made products of extruded polystyrene foam (XPS)—Specification..., (“DIN EN 13165”), Thermal insulation products for buildings—Factory made rigid polyurethane foam (PUR...

  15. From electronic consumer products to e-wastes: Global outlook, waste quantities, recycling challenges.

    PubMed

    Tansel, Berrin

    2017-01-01

    Advancements in technology, materials development, and manufacturing processes have changed the consumer products and composition of municipal solid waste (MSW) since 1960s. Increasing quantities of discarded consumer products remain a major challenge for recycling efforts, especially for discarded electronic products (also referred as e-waste). The growing demand for high tech products has increased the e-waste quantities and its cross boundary transport globally. This paper reviews the challenges associated with increasing e-waste quantities. The increasing need for raw materials (especially for rare earth and minor elements) and unregulated e-waste recycling operations in developing and underdeveloped counties contribute to the growing concerns for e-waste management. Although the markets for recycled materials are increasing; there are major challenges for development of the necessary infrastructure for e-waste management and accountability as well as development of effective materials recovery technologies and product design. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Concrete Durability: A Multibillion-Dollar Opportunity

    DTIC Science & Technology

    1987-01-01

    Fum -Containing Products 79 MDF Materials 85 Fiber-Reinforced Materials 85 Modified - Sulfur Concretes 87 References 88 APPENDIX: BIOGRAPHICAL SKETCHES...construction. MODIFIED - SULFUR CONCRETES Molten sulfur-sand grouts have been used for many years in the constructLin of acid vats because of their

  17. Liquid and gaseous oxygen safety review

    NASA Technical Reports Server (NTRS)

    Lapin, A.

    1973-01-01

    Materials used in oxygen systems and allowable oxygen environments are specified for each material. Design criteria, cleaning procedures and quality control methods are covered. Guidelines for protection against hazards involved with production, transportation, storage and use of oxygen are presented. Study also lists extensive references.

  18. Development of Lentivirus-Based Reference Materials for Ebola Virus Nucleic Acid Amplification Technology-Based Assays.

    PubMed

    Mattiuzzo, Giada; Ashall, James; Doris, Kathryn S; MacLellan-Gibson, Kirsty; Nicolson, Carolyn; Wilkinson, Dianna E; Harvey, Ruth; Almond, Neil; Anderson, Robert; Efstathiou, Stacey; Minor, Philip D; Page, Mark

    2015-01-01

    The 2013-present Ebola virus outbreak in Western Africa has prompted the production of many diagnostic assays, mostly based on nucleic acid amplification technologies (NAT). The calibration and performance assessment of established assays and those under evaluation requires reference materials that can be used in parallel with the clinical sample to standardise or control for every step of the procedure, from extraction to the final qualitative/quantitative result. We have developed safe and stable Ebola virus RNA reference materials by encapsidating anti sense viral RNA into HIV-1-like particles. The lentiviral particles are replication-deficient and non-infectious due to the lack of HIV-1 genes and Envelope protein. Ebola virus genes were subcloned for encapsidation into two lentiviral preparations, one containing NP-VP35-GP and the other VP40 and L RNA. Each reference material was formulated as a high-titre standard for use as a calibrator for secondary or internal standards, and a 10,000-fold lower titre preparation to serve as an in-run control. The preparations have been freeze-dried to maximise stability. These HIV-Ebola virus RNA reference materials were suitable for use with in-house and commercial quantitative RT-PCR assays and with digital RT-PCR. The HIV-Ebola virus RNA reference materials are stable at up to 37°C for two weeks, allowing the shipment of the material worldwide at ambient temperature. These results support further evaluation of the HIV-Ebola virus RNA reference materials as part of an International collaborative study for the establishment of the 1st International Standard for Ebola virus RNA.

  19. Soliciting Strategies for Developing Cell-Based Reference Materials to Advance Mesenchymal Stromal Cell Research and Clinical Translation

    PubMed Central

    Viswanathan, Sowmya; Keating, Armand; Deans, Robert; Hematti, Peiman; Prockop, Darwin; Stroncek, David F.; Stacey, Glyn; Weiss, Dan J.; Mason, Christopher

    2014-01-01

    The mesenchymal stromal cell (MSC) field continues to rapidly progress with a number of clinical trials initiated and completed, with some reported successes in multiple clinical indications, and a growing number of companies established. The field, nevertheless, faces several challenges. Persistent issues include the definition of a MSC and comparability between MSC preparations. This is because of inherent cell heterogeneity, the absence of markers that are unique to MSCs, and the difficulty in precisely defining them by developmental origin. Differences in the properties of MSCs also depend on the site of tissue harvest, phenotypic and genotypic characteristics of the donor and the isolation, and storage and expansion methods used. These differences may be sufficient to ensure that attributes of the final MSC product could differ in potentially significant ways. Since there are currently no gold standards, we propose using a reference material to establish methods of comparability among MSC preparations. We suggest four possible “ruler scenarios” and a method for global distribution. We further suggest that critical to establishing a reference material is the need to define protocols for comparing cells. The main purpose of this article is to solicit input in establishing a consensus-based comparison. A comparative approach will be critical to all stages of translation to better clarify mechanisms of MSC actions, define an optimal cell manufacturing process, ensure best practice clinical investigations, extend the use of an MSC product for new indications, protect an MSC product from imitators, and develop uniform reimbursement policies. Importantly, a reference material may enable a consensus on a practical definition of MSCs. PMID:24422625

  20. Establishment of a standard reference material (SRM) herbal DNA barcode library of Vitex negundo L. (lagundi) for quality control measures.

    PubMed

    Olivar, Jay Edneil C; Alaba, Joanner Paulus Erik P; Atienza, Jose Francisco M; Tan, Jerick Jeffrey S; Umali, Maximo T; Alejandro, Grecebio Jonathan D

    2016-05-01

    The majority of the population in the Philippines relies on herbal products as their primary source for their healthcare needs. After the recognition of Vitex negundo L. (lagundi) as an important and effective alternative medicine for cough, sore throat, asthma and fever by the Philippine Department of Health (DOH), there was an increase in the production of lagundi-based herbal products in the form of teas, capsules and syrups. The efficiency of these products is greatly reliant on the use of authentic plant material, and to this day no standard protocol has been established to authenticate plant materials. DNA barcoding offers a quick and reliable species authentication tool, but its application to plant material has been less successful due to (1) lack of a standard DNA barcoding loci in plants and (2) poor DNA yield from powderised plant products. This study reports the successful application of DNA barcoding in the authentication of five V. negundo herbal products sold in the Philippines. Also, the first standard reference material (SRM) herbal library for the recognition of authentic V. negundo samples was established using 42 gene accessions of ITS, psbA-trnH and matK barcoding loci. Authentication of the herbal products utilised the SRM following the BLASTn and maximum-likelihood (ML) tree construction criterion. Barcode sequences were retrieved for ITS and psbA-trnH of all products tested and the results of the study revealed that only one out of five herbal products satisfied both BLASTn and ML criterion and was considered to contain authentic V. negundo. The results prompt the urgent need to utilise DNA barcoding in authenticating herbal products available in the Philippine market. Authentication of these products will secure consumer health by preventing the negative effects of adulteration, substitution and contamination.

  1. 40 CFR 63.14 - Incorporations by reference.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Testing and Materials (ASTM), 100 Barr Harbor Drive, Post Office Box C700, West Conshohocken, PA 19428... (Reapproved 2010), Standard Test Method for Water in Petroleum Products and Bituminous Materials by...-09 Standard Test Method for Heat of Combustion of Liquid Hydrocarbon Fuels by Bomb Calorimeter...

  2. Literacy demands of product information intended to supplement television direct-to-consumer prescription drug advertisements.

    PubMed

    Kaphingst, Kimberly A; Rudd, Rima E; DeJong, William; Daltroy, Lawren H

    2004-11-01

    The US Food and Drug Administration (FDA) allows television direct-to-consumer (DTC) prescription drug advertisements that do not fully disclose drug risks if the ads include "adequate provision" for dissemination of the drug's approved labeling. This requirement can be met in part by referring consumers to multiple text sources of product labeling. This study was designed to assess the materials to which consumers were referred in 23 DTC television advertisements. SMOG assessments showed that the average reading grade levels were in the high school range for the main body sections of the materials and college-level range for the brief summary sections. The Suitability Assessment of Materials (SAM) instrument identified specific difficulties with the materials, including content, graphics, layout, and typography features. Stronger plain language requirements are recommended. Health care providers should be aware that patients who ask about an advertised drug might not have the full information required to make an informed decision.

  3. From Ephemeral to Legitimate: An Inquiry into Television's Material Traces in Archival Spaces, 1950s-1970s

    ERIC Educational Resources Information Center

    Bratslavsky, Lauren Michelle

    2013-01-01

    The dissertation offers a historical inquiry about how television's material traces entered archival spaces. Material traces refer to both the moving image products and the assortment of documentation about the processes of television as industrial and creative endeavors. By identifying the development of television-specific archives and…

  4. Metrological aspects of enzyme production

    NASA Astrophysics Data System (ADS)

    Kerber, T. M.; Dellamora-Ortiz, G. M.; Pereira-Meirelles, F. V.

    2010-05-01

    Enzymes are frequently used in biotechnology to carry out specific biological reactions, either in industrial processes or for the production of bioproducts and drugs. Microbial lipases are an important group of biotechnologically valuable enzymes that present widely diversified applications. Lipase production by microorganisms is described in several published papers; however, none of them refer to metrological evaluation and the estimation of the uncertainty in measurement. Moreover, few of them refer to process optimization through experimental design. The objectives of this work were to enhance lipase production in shaken-flasks with Yarrowia lipolytica cells employing experimental design and to evaluate the uncertainty in measurement of lipase activity. The highest lipolytic activity obtained was about three- and fivefold higher than the reported activities of CRMs BCR-693 and BCR-694, respectively. Lipase production by Y. lipolytica cells aiming the classification as certified reference material is recommended after further purification and stability studies.

  5. [Which one is more important, raw materials or productive technology?--a case study for quality consistency control of Gegen Qinlian decoction].

    PubMed

    Zhong, Wen; Chen, Sha; Zhang, Jun; Wang, Yu-Sheng; Liu, An

    2016-03-01

    To investigate the effect of Chinese medicine raw materials and production technology on quality consistency of Chinese patent medicines with Gegen Qinlian decoction as an example, and establish a suitable method for the quality consistency control of Chinese patent medicines. The results showed that the effect of production technology on the quality consistency was generally not more than 5%, while the effect of raw materials was even more than 30%, indicating that the effect of raw materials was much greater than that of the production technology. In this study, blend technology was used to improve the quality consistency of raw materials. As a result, the difference between the product produced by raw materials and reference groups was less than 5%, thus increasing the quality consistence of finished products. The results showed that under the current circumstances, the main factor affecting the quality consistency of Chinese patent medicines was raw materials, so we shall pay more attention to the quality of Chinese medicine's raw materials. Finally, a blend technology can improve the quality consistency of Chinese patent medicines. Copyright© by the Chinese Pharmaceutical Association.

  6. [Preparation and certification of mussel reference material for organochlorine pesticides and polychlorinated biphenyls using isotope dilution-high resolution mass spectrometry].

    PubMed

    Lu, Xianbo; Chen, Jiping; Wang, Shuqiu; Zou, Lili; Tian, Yuzeng; Ni, Yuwen; Su, Fan

    2012-09-01

    A method for the preparation and certification of the reference material of organochlorine pesticides (OCPs) and polychlorinated biphenyls (PCBs) in mussel tissue is described. The mussel tissue from Dalian Bay was frozen-dried, comminuted, sieved, homogenized, packaged, and sterilized by 60Co radiation sterilization in turn. The certified values for 18 OCPs and 16 PCBs were determined by high resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS) using isotope dilution and internal standard quantitation techniques. The certified values were validated and given based on seven accredited laboratories, and these values are traceable to the SI (international system of units) through gravimetrically prepared standards of established purity and measurement intercomparisons. The certified values of PCBs and OCPs in mussel span 4 orders of magnitude with a relative uncertainty of about 10%. This material is a natural biological material with confirmed good homogeneity and stability, and it was approved as the grade "primary reference material" (GBW10069) in June 2012 in China. This reference material provided necessary quality control products for our country to implement the Stockholm Treaty on the monitoring of persistent organic pollutants (POPs). The material is intended to be used for the method validation and quality control in the determination of OCPs and PCBs in biota samples.

  7. Instructional Media Production for Early Childhood Education: A. B. C. Jig-Saw Puzzle, a Model

    ERIC Educational Resources Information Center

    Yusuf, Mudashiru Olalere; Olanrewaju, Olatayo Solomon; Soetan, Aderonke K.

    2015-01-01

    In this paper, a. b. c. jig-saw puzzle was produced for early childhood education using local materials. This study was a production based type of research, to serve as a supplemental or total learning resource. Its production followed four phases of development referred to as information, design, production and evaluation. The storyboard cards,…

  8. Metrological traceability of holmium oxide solution

    NASA Astrophysics Data System (ADS)

    Gonçalves, D. E. F.; Gomes, J. F. S.; Alvarenga, A. P. D.; Borges, P. P.; Araujo, T. O.

    2018-03-01

    Holmium oxide solution was prepared as a candidate of certified reference material for spectrophotometer wavelength scale calibration. Here is presented the necessary steps for evaluation of the uncertainty and the establishment of metrological traceability for the production of this material. Preliminary results from the first produced batch are shown.

  9. Faculty Productivity: Practice and Policy.

    ERIC Educational Resources Information Center

    Quigley, E. James

    Information was obtained on current or recently proposed legislation, administrative regulations, policies, practices, reports or studies on any aspect of faculty productivity, faculty workload or teaching load, or faculty activity analysis. Responses were obtained from 34 states. Responses for the 14 states that provided reference material are…

  10. WHO Expert Committee on Biological Standardization.

    PubMed

    2002-01-01

    This report presents the recommendations of a WHO Expert Committee commissioned to coordinate activities leading to the adoption of international recommendations for the production and quality control of vaccines and other biologicals and the establishment of international biological reference materials. The report starts with a discussion of general issues brought to the attention of the Committee and provides information on issues relevant to international guidelines, recommendations and other matters related to the manufacture and quality control of biologicals. This is followed by information on the status and development of reference materials for bovine spongiform encephalopathy, various antigens, blood products, cytokines, growth factors and endocrinological substances. The second part of the report, of particular interest to manufacturers and national control authorities, contains sets of recommendations for the production and control of poliomyelitis vaccine (oral) and poliomyelitis vaccine (inactivated) and guidelines for the production and control of live attenuated Japanese encephalitis vaccine. Also included are lists of recommendations and guidelines for biological substances used in medicine, and other relevant documents.

  11. Introduction to Poultry Production. Instructor Guide [and] Student Reference. Volume 31, Number 3 [and] Number 4.

    ERIC Educational Resources Information Center

    Raphael, Katherine

    This packet contains both teacher and student materials for a unit on poultry production in vocational agriculture courses and covers the following lessons: (1) overview of the poultry industry; (2) selection and evaluation; (3) production; (4) reproduction; (5) health issues; and (6) processing and marketing. The lessons include the following…

  12. 26 CFR 52.4682-3 - Imported taxable products.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ....4682-3 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) MISCELLANEOUS...; references to Tables; special rule for 1990—(1) Overview. This section provides rules relating to the tax... products, determining the weight of the ozone-depleting chemicals (ODCs) used as materials in the...

  13. Soil Conservation Unit for the Advanced Crop Production and Marketing Course. Student Reference. AGDEX 570.

    ERIC Educational Resources Information Center

    Stewart, Bob R.; And Others

    This student reference booklet is designed to accompany lessons outlined in the companion instructor's guide on soil conservation. The soil conservation unit builds on competencies gained in Agricultural Science I and II. Informative material is provided for these eight lessons: benefits of conservation, land utilization, how soils are eroded,…

  14. 21 CFR 20.100 - Applicability; cross-reference to other regulations.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... of this chapter. (25) Cosmetic establishment registrations, in § 710.7 of this chapter. (26) Cosmetic product ingredient and cosmetic raw material composition statements, § 720.8 of this chapter. (27) Cosmetic product experience reports, in § 730.7 of this chapter. (28) Device premarket notification...

  15. 21 CFR 20.100 - Applicability; cross-reference to other regulations.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... of this chapter. (25) Cosmetic establishment registrations, in § 710.7 of this chapter. (26) Cosmetic product ingredient and cosmetic raw material composition statements, § 720.8 of this chapter. (27) Cosmetic product experience reports, in § 730.7 of this chapter. (28) Device premarket notification...

  16. Characterization of NIES CRM No. 23 Tea Leaves II for the determination of multielements.

    PubMed

    Mori, Ikuko; Ukachi, Miyuki; Nagano, Kimiyo; Ito, Hiroyasu; Yoshinaga, Jun; Nishikawa, Masataka

    2010-05-01

    A candidate environmental certified reference material (CRM) for the determination of multielements in tea leaves and materials of similar matrix, NIES CRM No. 23 Tea Leaves II, has been developed and characterized by the National Institute for Environmental Studies (NIES), Japan. The origin of the material was tea leaves, which were ground, sieved through a 106-microm mesh, homogenized, and then subdivided into amber glass bottles. The results of homogeneity and stability tests indicated that the material was sufficiently homogeneous and stable for use as a reference material. The property values of the material were statistically determined based on chemical analyses by a network of laboratories using a wide range of methods. Sixteen laboratories participated in the characterization, and nine certified values and five reference values were obtained. These property values of the candidate CRM, which are expressed as mass fractions, were close to the median and/or mean values of the mass fractions of elements in various tea products. The candidate CRM is appropriate for use in analytical quality control and in the evaluation of methods used in the analysis of tea and materials of similar matrix.

  17. Certified reference materials for testing of the presence/absence of Staphylococcus aureus enterotoxin A (SEA) in cheese.

    PubMed

    Zeleny, Reinhard; Nia, Yacine; Schimmel, Heinz; Mutel, Isabelle; Hennekinne, Jacques-Antoine; Emteborg, Håkan; Charoud-Got, Jean; Auvray, Frédéric

    2016-08-01

    Staphylococcal enterotoxins (SEs) account for a substantial number of food-poisoning outbreaks. European legislation (Commission Regulation 1441/2007) stipulates the reference procedure for SE analysis in milk and dairy products, which is based on extraction, dialysis concentration and immunochemical detection using one of two approved assays (VIDAS(®) SET2, Ridascreen(®) SET Total). However, certified reference materials (CRMs) are lacking to support laboratories in performing reliable detection of Staphylococcus aureus enterotoxin A (SEA) in relevant matrices at sub-nanogram per gram levels. The certification of a set of three reference materials (blank and two SEA-containing materials) for testing of the presence/absence of SEA in cheese is described. The reference procedure was applied in an intercomparison with 15 laboratories, and results were reported in a qualitative manner (presence or absence of SEA in the sample). No false-negative or false-positive results were obtained. The certified values were stated as diagnostic specificity (blank material) or diagnostic sensitivity (SEA-containing materials) and were 100 % in all cases. Stability studies demonstrated suitable material stability when stored cooled or frozen. An in-house study on the recovery of SEA in the cheese materials using a double-sandwich enzyme-linked immunosorbent assay (ELISA) revealed comparable recovery values of around 45 % at the two spiking levels and in both the SEA-containing CRMs as well as blank CRM freshly spiked prior to analysis. The values were also comparable over time and among different analysts. The materials provide valuable support to laboratories for method validation and method performance verification and will increase the reliability of measuring SEA in cheese.

  18. Collective Bargaining for Public Managers (State and Local): Reference Materials.

    ERIC Educational Resources Information Center

    Civil Service Commission, Washington, DC. Labor Relations Training Center.

    The book contain pertinent articles on various subjects related to collective bargaining. It was developed and the materials specially written for use by instructors in a collective bargaining course designed to assist public sector managers in attaining a stable and productive labor relations environment. Each article has been keyed to the…

  19. Advanced Beef Unit for Advanced Livestock Production Curriculum. Instructor's Guide. AGDEX 420/00.

    ERIC Educational Resources Information Center

    Sparks, Jim; Stewart, Bob R.

    This instructor's guide for an advanced beef unit contains 15 lessons that build on Agricultural Science I and II competencies. Introductory materials include lists of performance objectives and competencies for the complete unit, suggestions for motivational technique/interest approach and evaluation, lists of references and materials for the…

  20. Quantification of the predominant monomeric catechins in baking chocolate standard reference material by LC/APCI-MS.

    PubMed

    Nelson, Bryant C; Sharpless, Katherine E

    2003-01-29

    Catechins are polyphenolic plant compounds (flavonoids) that may offer significant health benefits to humans. These benefits stem largely from their anticarcinogenic, antioxidant, and antimutagenic properties. Recent epidemiological studies suggest that the consumption of flavonoid-containing foods is associated with reduced risk of cardiovascular disease. Chocolate is a natural cocoa bean-based product that reportedly contains high levels of monomeric, oligomeric, and polymeric catechins. We have applied solid-liquid extraction and liquid chromatography coupled with atmospheric pressure chemical ionization-mass spectrometry to the identification and determination of the predominant monomeric catechins, (+)-catechin and (-)-epicatechin, in a baking chocolate Standard Reference Material (NIST Standard Reference Material 2384). (+)-Catechin and (-)-epicatechin are detected and quantified in chocolate extracts on the basis of selected-ion monitoring of their protonated [M + H](+) molecular ions. Tryptophan methyl ester is used as an internal standard. The developed method has the capacity to accurately quantify as little as 0.1 microg/mL (0.01 mg of catechin/g of chocolate) of either catechin in chocolate extracts, and the method has additionally been used to certify (+)-catechin and (-)-epicatechin levels in the baking chocolate Standard Reference Material. This is the first reported use of liquid chromatography/mass spectrometry for the quantitative determination of monomeric catechins in chocolate and the only report certifying monomeric catechin levels in a food-based Standard Reference Material.

  1. Synthetic Reference Materials Based on Polymer Films for the Control of Welding Fumes Composition

    NASA Astrophysics Data System (ADS)

    Kuznetsova, O. V.; Kuznetsova, A. N.; Begunova, L. A.

    2017-04-01

    Analysis of the current hygienic situation in the welding production showed that the intensification of welding processes involves the deterioration of air quality, which negatively affects the welders health. Welders are exposed to a variety of metal fumes, including manganese that may elevate the risk for neurological diseases. The control of metals concentration in the air of the working area is difficult due to the lack of reference materials. The creation of reference materials of welding fumes composition is a challenge due to chemical characteristics of their physical properties. Synthetic samples in a form of the polymer film containing powder particles of welding fumes were create. Studies on the selection of the polymer were done. Experiments proved that the qualitative materials of synthetic welding fumes are obtained by using polyvinyl alcohol. The metals concentration in the samples was determined by X-ray fluorescence analysis. The obtained data demonstrates indirectly the uniform distribution of welding fumes powder particles on the polymer film.

  2. Development of a candidate reference material for adventitious virus detection in vaccine and biologicals manufacturing by deep sequencing

    PubMed Central

    Mee, Edward T.; Preston, Mark D.; Minor, Philip D.; Schepelmann, Silke; Huang, Xuening; Nguyen, Jenny; Wall, David; Hargrove, Stacey; Fu, Thomas; Xu, George; Li, Li; Cote, Colette; Delwart, Eric; Li, Linlin; Hewlett, Indira; Simonyan, Vahan; Ragupathy, Viswanath; Alin, Voskanian-Kordi; Mermod, Nicolas; Hill, Christiane; Ottenwälder, Birgit; Richter, Daniel C.; Tehrani, Arman; Jacqueline, Weber-Lehmann; Cassart, Jean-Pol; Letellier, Carine; Vandeputte, Olivier; Ruelle, Jean-Louis; Deyati, Avisek; La Neve, Fabio; Modena, Chiara; Mee, Edward; Schepelmann, Silke; Preston, Mark; Minor, Philip; Eloit, Marc; Muth, Erika; Lamamy, Arnaud; Jagorel, Florence; Cheval, Justine; Anscombe, Catherine; Misra, Raju; Wooldridge, David; Gharbia, Saheer; Rose, Graham; Ng, Siemon H.S.; Charlebois, Robert L.; Gisonni-Lex, Lucy; Mallet, Laurent; Dorange, Fabien; Chiu, Charles; Naccache, Samia; Kellam, Paul; van der Hoek, Lia; Cotten, Matt; Mitchell, Christine; Baier, Brian S.; Sun, Wenping; Malicki, Heather D.

    2016-01-01

    Background Unbiased deep sequencing offers the potential for improved adventitious virus screening in vaccines and biotherapeutics. Successful implementation of such assays will require appropriate control materials to confirm assay performance and sensitivity. Methods A common reference material containing 25 target viruses was produced and 16 laboratories were invited to process it using their preferred adventitious virus detection assay. Results Fifteen laboratories returned results, obtained using a wide range of wet-lab and informatics methods. Six of 25 target viruses were detected by all laboratories, with the remaining viruses detected by 4–14 laboratories. Six non-target viruses were detected by three or more laboratories. Conclusion The study demonstrated that a wide range of methods are currently used for adventitious virus detection screening in biological products by deep sequencing and that they can yield significantly different results. This underscores the need for common reference materials to ensure satisfactory assay performance and enable comparisons between laboratories. PMID:26709640

  3. Determination of the purity of pharmaceutical reference materials by 1H NMR using the standardless PULCON methodology.

    PubMed

    Monakhova, Yulia B; Kohl-Himmelseher, Matthias; Kuballa, Thomas; Lachenmeier, Dirk W

    2014-11-01

    A fast and reliable nuclear magnetic resonance spectroscopic method for quantitative determination (qNMR) of targeted molecules in reference materials has been established using the ERETIC2 methodology (electronic reference to access in vivo concentrations) based on the PULCON principle (pulse length based concentration determination). The developed approach was validated for the analysis of pharmaceutical samples in the context of official medicines control, including ibandronic acid, amantadine, ambroxol and lercanidipine. The PULCON recoveries were above 94.3% and coefficients of variation (CVs) obtained by quantification of different targeted resonances ranged between 0.7% and 2.8%, demonstrating that the qNMR method is a precise tool for rapid quantification (approximately 15min) of reference materials and medicinal products. Generally, the values were within specification (certified values) provided by the manufactures. The results were in agreement with NMR quantification using an internal standard and validated reference HPLC analysis. The PULCON method was found to be a practical alternative with competitive precision and accuracy to the classical internal reference method and it proved to be applicable to different solvent conditions. The method can be recommended for routine use in medicines control laboratories, especially when the availability and costs of reference compounds are problematic. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Bioequivalence of generic alendronate sodium tablets (70 mg) to Fosamax® tablets (70 mg) in fasting, healthy volunteers: a randomized, open-label, three-way, reference-replicated crossover study

    PubMed Central

    Zhang, Yifan; Chen, Xiaoyan; Tang, Yunbiao; Lu, Youming; Guo, Lixia; Zhong, Dafang

    2017-01-01

    Purpose The aim of this study was to evaluate the bioequivalence of a generic product 70 mg alendronate sodium tablets with the reference product Fosamax® 70 mg tablet. Materials and methods A single-center, open-label, randomized, three-period, three-sequence, reference-replicated crossover study was performed in 36 healthy Chinese male volunteers under fasting conditions. In each study period, the volunteers received a single oral dose of the generic or reference product (70 mg). Blood samples were collected at pre-dose and up to 8 h after administration. The bioequivalence of the generic product to the reference product was assessed using the US Food and Drug Administration (FDA) and European Medicines Agency (EMA) reference-scaled average bioequivalence (RSABE) methods. Results The average maximum concentrations (Cmax) of alendronic acid were 64.78±43.76, 56.62±31.95, and 60.15±37.12 ng/mL after the single dose of the generic product and the first and second doses of the reference product, respectively. The areas under the plasma concentration–time curves from time 0 to the last timepoint (AUC0–t) were 150.36±82.90, 148.15±85.97, and 167.11±110.87 h⋅ng/mL, respectively. Reference scaling was used because the within-subject standard deviations of the reference product (sWR) for Cmax and AUC0–t were all higher than the cutoff value of 0.294. The 95% upper confidence bounds were −0.16 and −0.17 for Cmax and AUC0–t, respectively, and the point estimates for the generic/reference product ratio were 1.08 and 1.00, which satisfied the RSABE acceptance criteria of the FDA. The 90% CIs for Cmax and AUC0–t were 90.35%–129.04% and 85.31%–117.15%, respectively, which were within the limits of the EMA for the bioequivalence of 69.84%–143.19% and 80.00%–125.00%. Conclusion The generic product was bioequivalent to the reference product in terms of the rate and extent of alendronate absorption after a single 70 mg oral dose under fasting conditions. PMID:28744102

  5. ETV/ESTE RADIO FREQUENCY IDENTIFICATION PROJECT

    EPA Science Inventory

    The final product for book chapter is not available for this material. If further information is needed, please refer to the bibliographic citation and contact the person listed under the Contract Field.

  6. Routine inspection effort required for verification of a nuclear material production cutoff convention

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dougherty, D.; Fainberg, A.; Sanborn, J.

    On 27 September 1993, President Clinton proposed {open_quotes}... a multilateral convention prohibiting the production of highly enriched uranium or plutonium for nuclear explosives purposes or outside of international safeguards.{close_quotes} The UN General Assembly subsequently adopted a resolution recommending negotiation of a non-discriminatory, multilateral, and internationally and effectively verifiable treaty (hereinafter referred to as {open_quotes}the Cutoff Convention{close_quotes}) banning the production of fissile material for nuclear weapons. The matter is now on the agenda of the Conference on Disarmament, although not yet under negotiation. This accord would, in effect, place all fissile material (defined as highly enriched uranium and plutonium) produced aftermore » entry into force (EIF) of the accord under international safeguards. {open_quotes}Production{close_quotes} would mean separation of the material in question from radioactive fission products, as in spent fuel reprocessing, or enrichment of uranium above the 20% level, which defines highly enriched uranium (HEU). Facilities where such production could occur would be safeguarded to verify that either such production is not occurring or that all material produced at these facilities is maintained under safeguards.« less

  7. Uranium Mining and Norm in North America-Some Perspectives on Occupational Radiation Exposure.

    PubMed

    Brown, Steven H; Chambers, Douglas B

    2017-07-01

    All soils and rocks contain naturally occurring radioactive materials (NORM). Many ores and raw materials contain relatively elevated levels of natural radionuclides, and processing such materials can further increase the concentrations of naturally occurring radionuclides. In the U.S., these materials are sometimes referred to as technologically-enhanced naturally occurring radioactive materials (TENORM). Examples of NORM minerals include uranium ores, monazite (a source of rare earth minerals), and phosphate rock used to produce phosphate fertilizer. The processing of these materials has the potential to result in above-background radiation exposure to workers. Following a brief review of the sources and potential for worker exposure from NORM in these varied industries, this paper will then present an overview of uranium mining and recovery in North America, including discussion on the mining methods currently being used for both conventional (underground, open pit) and in situ leach (ISL), also referred to as In Situ Recovery (ISR), and the production of NORM materials and wastes associated with these uranium recovery methods. The radiological composition of the NORM products and wastes produced and recent data on radiological exposures received by workers in the North American uranium recovery industry are then described. The paper also identifies the responsible government agencies in the U.S. and Canada assigned the authority to regulate and control occupational exposure from these NORM materials.

  8. Reduced detrital resources limit Pycnopsyche gentilis (Trichoptera: Limnephilidae) production and growth

    Treesearch

    Susan L. Eggert; J. Bruce Wallace

    2003-01-01

    Leaf inputs in temperate forest streams may limit caddisfly production because leaf detritus serves both as a food and case-material resource. We estimated Pycnopsyche gentilis produdion in a stream experimentally decoupled fmm its riparian habitat and a reference stream for 8 y in the southern Appalachians. We also examined laboratory survivorship,...

  9. An automated protocol for performance benchmarking a widefield fluorescence microscope.

    PubMed

    Halter, Michael; Bier, Elianna; DeRose, Paul C; Cooksey, Gregory A; Choquette, Steven J; Plant, Anne L; Elliott, John T

    2014-11-01

    Widefield fluorescence microscopy is a highly used tool for visually assessing biological samples and for quantifying cell responses. Despite its widespread use in high content analysis and other imaging applications, few published methods exist for evaluating and benchmarking the analytical performance of a microscope. Easy-to-use benchmarking methods would facilitate the use of fluorescence imaging as a quantitative analytical tool in research applications, and would aid the determination of instrumental method validation for commercial product development applications. We describe and evaluate an automated method to characterize a fluorescence imaging system's performance by benchmarking the detection threshold, saturation, and linear dynamic range to a reference material. The benchmarking procedure is demonstrated using two different materials as the reference material, uranyl-ion-doped glass and Schott 475 GG filter glass. Both are suitable candidate reference materials that are homogeneously fluorescent and highly photostable, and the Schott 475 GG filter glass is currently commercially available. In addition to benchmarking the analytical performance, we also demonstrate that the reference materials provide for accurate day to day intensity calibration. Published 2014 Wiley Periodicals Inc. Published 2014 Wiley Periodicals Inc. This article is a US government work and, as such, is in the public domain in the United States of America.

  10. Reference materials for the monitoring of the aquatic environment--a review with special emphasis on organic priority pollutants.

    PubMed

    Bercaru, Ofelia; Gawlik, Bernd Manfred; Ulberth, Franz; Vandecasteele, Carlo

    2003-08-01

    During recent years, the awareness of quality assurance and quality control in environmental analyses has constantly increased, especially due to the implementation of new guidelines and regulations at both the national and international level. Achieving comparable results by using certified reference materials is one of the primary concerns of the scientific community. As a result, there is a growing demand for certified reference materials to cover different matrices and pollutants. Moreover, these CRMs should be in close relationship to the determinants and target concentrations required by environmental bodies and European Directives as well. Supplementary information to this paper presents an inventory of reference materials available on the market from different suppliers against the priority pollutants listed in the Water Framework Directive. These CRMs cover matrices such as water, sediment and biota. The use of CRMs in relationship to appropriate analytical methods and relevant determinants is discussed and the need for matrix-CRMs, particularly for organic pollutants is emphasised. The use of proficiency testing schemes as an alternative for the lack of appropriate CRMs and future trends in the production of CRMs within the BCR framework are also discussed.

  11. 40 CFR 92.5 - Reference materials.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., or at http://www.ansi.org. (1) ANSI B109.1-1992, Diaphragm Type Gas Displacment Meters, IBR approved..., Standard Test Method for API Gravity of Crude Petroleum and Petroleum Products (Hydrometer Method), IBR...

  12. 40 CFR 92.5 - Reference materials.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., or at http://www.ansi.org. (1) ANSI B109.1-1992, Diaphragm Type Gas Displacment Meters, IBR approved..., Standard Test Method for API Gravity of Crude Petroleum and Petroleum Products (Hydrometer Method), IBR...

  13. 40 CFR 92.5 - Reference materials.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., or at http://www.ansi.org. (1) ANSI B109.1-1992, Diaphragm Type Gas Displacment Meters, IBR approved..., Standard Test Method for API Gravity of Crude Petroleum and Petroleum Products (Hydrometer Method), IBR...

  14. 16 CFR 1608.6 - Reference to guaranty by Government prohibited.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... guaranty by Government prohibited. No representation nor suggestion shall be made in advertising or otherwise marketing or handling products, fabrics or related materials subject to the act that the act, the...

  15. CRISPR/Cas9 Technology-Based Xenograft Tumors as Candidate Reference Materials for Multiple EML4-ALK Rearrangements Testing.

    PubMed

    Peng, Rongxue; Zhang, Rui; Lin, Guigao; Yang, Xin; Li, Ziyang; Zhang, Kuo; Zhang, Jiawei; Li, Jinming

    2017-09-01

    The echinoderm microtubule-associated protein-like 4 and anaplastic lymphoma kinase (ALK) receptor tyrosine kinase (EML4-ALK) rearrangement is an important biomarker that plays a pivotal role in therapeutic decision making for non-small-cell lung cancer (NSCLC) patients. Ensuring accuracy and reproducibility of EML4-ALK testing by fluorescence in situ hybridization, immunohistochemistry, RT-PCR, and next-generation sequencing requires reliable reference materials for monitoring assay sensitivity and specificity. Herein, we developed novel reference materials for various kinds of EML4-ALK testing. CRISPR/Cas9 was used to edit various NSCLC cell lines containing EML4-ALK rearrangement variants 1, 2, and 3a/b. After s.c. inoculation, the formalin-fixed, paraffin-embedded (FFPE) samples from xenografts were prepared and tested for suitability as candidate reference materials by fluorescence in situ hybridization, immunohistochemistry, RT-PCR, and next-generation sequencing. Sample validation and commutability assessments showed that all types of FFPE samples derived from xenograft tumors have typical histological structures, and EML4-ALK testing results were similar to the clinical ALK-positive NSCLC specimens. Among the four methods for EML4-ALK detection, the validation test showed 100% concordance. Furthermore, these novel FFPE reference materials showed good stability and homogeneity. Without limitations on variant types and production, our novel FFPE samples based on CRISPR/Cas9 editing and xenografts are suitable as candidate reference materials for the validation, verification, internal quality control, and proficiency testing of EML4-ALK detection. Copyright © 2017 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  16. Collective Bargaining for Public Management (State and Local): Instructors Manual.

    ERIC Educational Resources Information Center

    Civil Service Commission, Washington, DC. Labor Relations Training Center.

    The instructor's manual for a four to five day course designed to assist public sector managers in attaining a stable and productive labor relations environment is intended for use with two other books, the Reference Materials and the Case Materials. The course, created principally for use in a formal classroom setting, can be adapted to suit the…

  17. The production of homozygous tree material

    Treesearch

    Reinhard F. Stettler; George E. Howe

    1966-01-01

    Homozygous trees will never be the desired ultimate step in a forest tree improvement program. However, they will serve many purposes in forest genetics research: (1) in the detection of genetic markers; (2) in the isolation of traits under simple genetic control for the study of growth and differentiation phenomena; (3) as a tool as well as reference material in the...

  18. Isotope dilution ICP-MS with laser-assisted sample introduction for direct determination of sulfur in petroleum products.

    PubMed

    Boulyga, Sergei F; Heilmann, Jens; Heumann, Klaus G

    2005-08-01

    Inductively coupled plasma isotope dilution mass spectrometry (ICP-IDMS) with direct laser-assisted introduction of isotope-diluted samples into the plasma, using a laser ablation system with high ablation rates, was developed for accurate sulfur determinations in different petroleum products such as 'sulfur-free' premium gasoline, diesel fuel, and heating oil. Two certified gas oil reference materials were analyzed for method validation. Two different 34S-enriched spike compounds, namely, elementary sulfur dissolved in xylene and dibenzothiophene in hexane, were synthesized and tested for their usefulness in this isotope dilution technique. The isotope-diluted sample was adsorbed on a filter-paper-like material, which was fixed in a special holder for irradiation by the laser beam. Under these conditions no time-dependent spike/analyte fractionation was only observed for the dibenzothiophene spike during the laser ablation process, which means that the measured 34S/32S isotope ratio of the isotope-diluted sample remained constant-a necessary precondition for accurate results with the isotope dilution technique. A comparison of LA-ICP-IDMS results with the certified values of the gas oil reference materials and with results obtained from ICP-IDMS analyses with wet sample digestion demonstrated the accuracy of the new LA-ICP-IDMS method in the concentration range of 9.2 microg g(-1) ('sulfur-free' premium gasoline) to 10.4 mg g(-1) (gas oil reference material BCR 107). The detection limit for sulfur by LA-ICP-IDMS is 0.04 microg g(-1) and the analysis time is only about 10 min, which therefore also qualifies this method for accurate determinations of low sulfur contents in petroleum products on a routine level.

  19. Determination of Vitamin E in Cereal Products and Biscuits by GC-FID.

    PubMed

    Pasias, Ioannis N; Kiriakou, Ioannis K; Papakonstantinou, Lila; Proestos, Charalampos

    2018-01-01

    A rapid, precise and accurate method for the determination of vitamin E (α-tocopherol) in cereal products and biscuits has been developed. The uncertainty was calculated for the first time, and the methods were performed for different cereal products and biscuits, characterized as "superfoods". The limits of detection and quantification were calculated. The accuracy and precision were estimated using the certified reference material FAPAS T10112QC, and the determined values were in good accordance with the certified values. The health claims according to the daily reference values for vitamin E were calculated, and the results proved that the majority of the samples examined showed a percentage daily value higher than 15%.

  20. Determination of Vitamin E in Cereal Products and Biscuits by GC-FID

    PubMed Central

    Kiriakou, Ioannis K.; Papakonstantinou, Lila

    2018-01-01

    A rapid, precise and accurate method for the determination of vitamin E (α-tocopherol) in cereal products and biscuits has been developed. The uncertainty was calculated for the first time, and the methods were performed for different cereal products and biscuits, characterized as “superfoods”. The limits of detection and quantification were calculated. The accuracy and precision were estimated using the certified reference material FAPAS T10112QC, and the determined values were in good accordance with the certified values. The health claims according to the daily reference values for vitamin E were calculated, and the results proved that the majority of the samples examined showed a percentage daily value higher than 15%. PMID:29301245

  1. 46 CFR 30.01-3 - Incorporation by reference.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... and Materials (ASTM), 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959, telephone 610-832-9585, http://www.astm.org. (1) ASTM D 323-94, Standard Test Method for Vapor Pressure of Petroleum Products...

  2. Creating Documentaries.

    ERIC Educational Resources Information Center

    Beasley, Augie

    1994-01-01

    Explains production techniques involved in making student documentaries on video. Highlights include student research; script writing; narration; the use of interviews; incorporating visual materials such as maps and photographs; camera techniques; demonstrations; editing; and time limits. (Contains six references.) (LRW)

  3. Agencies Need Better Guidance for Choosing among Contracts, Grants, and Cooperative Agreements.

    DTIC Science & Technology

    1981-09-04

    given case may require reference to a range of materials . By en- acting specific authorizing language and providing various sources to help an agency...to: --Inventory recipients’ training materials , get them well-edited, and ready for the agency’s approval, production and distribution. [service... materials to those that do. REA indicated in its Federal Register announcement that under Section 11 of the Rural Electrification Act and under the

  4. Enabling consistency in pluripotent stem cell-derived products for research and development and clinical applications through material standards.

    PubMed

    French, Anna; Bravery, Christopher; Smith, James; Chandra, Amit; Archibald, Peter; Gold, Joseph D; Artzi, Natalie; Kim, Hae-Won; Barker, Richard W; Meissner, Alexander; Wu, Joseph C; Knowles, Jonathan C; Williams, David; García-Cardeña, Guillermo; Sipp, Doug; Oh, Steve; Loring, Jeanne F; Rao, Mahendra S; Reeve, Brock; Wall, Ivan; Carr, Andrew J; Bure, Kim; Stacey, Glyn; Karp, Jeffrey M; Snyder, Evan Y; Brindley, David A

    2015-03-01

    There is a need for physical standards (reference materials) to ensure both reproducibility and consistency in the production of somatic cell types from human pluripotent stem cell (hPSC) sources. We have outlined the need for reference materials (RMs) in relation to the unique properties and concerns surrounding hPSC-derived products and suggest in-house approaches to RM generation relevant to basic research, drug screening, and therapeutic applications. hPSCs have an unparalleled potential as a source of somatic cells for drug screening, disease modeling, and therapeutic application. Undefined variation and product variability after differentiation to the lineage or cell type of interest impede efficient translation and can obscure the evaluation of clinical safety and efficacy. Moreover, in the absence of a consistent population, data generated from in vitro studies could be unreliable and irreproducible. Efforts to devise approaches and tools that facilitate improved consistency of hPSC-derived products, both as development tools and therapeutic products, will aid translation. Standards exist in both written and physical form; however, because many unknown factors persist in the field, premature written standards could inhibit rather than promote innovation and translation. We focused on the derivation of physical standard RMs. We outline the need for RMs and assess the approaches to in-house RM generation for hPSC-derived products, a critical tool for the analysis and control of product variation that can be applied by researchers and developers. We then explore potential routes for the generation of RMs, including both cellular and noncellular materials and novel methods that might provide valuable tools to measure and account for variation. Multiparametric techniques to identify "signatures" for therapeutically relevant cell types, such as neurons and cardiomyocytes that can be derived from hPSCs, would be of significant utility, although physical RMs will be required for clinical purposes. ©AlphaMed Press.

  5. Enabling Consistency in Pluripotent Stem Cell-Derived Products for Research and Development and Clinical Applications Through Material Standards

    PubMed Central

    Bravery, Christopher; Smith, James; Chandra, Amit; Archibald, Peter; Gold, Joseph D.; Artzi, Natalie; Kim, Hae-Won; Barker, Richard W.; Meissner, Alexander; Wu, Joseph C.; Knowles, Jonathan C.; Williams, David; García-Cardeña, Guillermo; Sipp, Doug; Oh, Steve; Loring, Jeanne F.; Rao, Mahendra S.; Reeve, Brock; Wall, Ivan; Carr, Andrew J.; Bure, Kim; Stacey, Glyn; Karp, Jeffrey M.

    2015-01-01

    Summary There is a need for physical standards (reference materials) to ensure both reproducibility and consistency in the production of somatic cell types from human pluripotent stem cell (hPSC) sources. We have outlined the need for reference materials (RMs) in relation to the unique properties and concerns surrounding hPSC-derived products and suggest in-house approaches to RM generation relevant to basic research, drug screening, and therapeutic applications. hPSCs have an unparalleled potential as a source of somatic cells for drug screening, disease modeling, and therapeutic application. Undefined variation and product variability after differentiation to the lineage or cell type of interest impede efficient translation and can obscure the evaluation of clinical safety and efficacy. Moreover, in the absence of a consistent population, data generated from in vitro studies could be unreliable and irreproducible. Efforts to devise approaches and tools that facilitate improved consistency of hPSC-derived products, both as development tools and therapeutic products, will aid translation. Standards exist in both written and physical form; however, because many unknown factors persist in the field, premature written standards could inhibit rather than promote innovation and translation. We focused on the derivation of physical standard RMs. We outline the need for RMs and assess the approaches to in-house RM generation for hPSC-derived products, a critical tool for the analysis and control of product variation that can be applied by researchers and developers. We then explore potential routes for the generation of RMs, including both cellular and noncellular materials and novel methods that might provide valuable tools to measure and account for variation. Multiparametric techniques to identify “signatures” for therapeutically relevant cell types, such as neurons and cardiomyocytes that can be derived from hPSCs, would be of significant utility, although physical RMs will be required for clinical purposes. PMID:25650438

  6. [Evidence-based management of medical disposable materials].

    PubMed

    Yang, Hai

    2009-03-01

    Evidence-based management of medical disposable materials pays attention to collect evidence comprehensively and systematically, accumulate and create evidence through its own work and also evaluate evidence strictly. This can be used as a function to guide out job. Medical disposable materials evidence system contains product register qualification, product quality certification, supplier's behavior, internal and external communication evidence. Managers can find different ways in creating and using evidence referring to specific inside and outside condition. Evidence-based management can help accelerating the development of management of medical disposable materials from traditional experience pattern to a systematic and scientific pattern. It also has the very important meaning to improve medical quality, control the unreasonable growth of medical expense and make purchase and supply chain be more efficient.

  7. High-purity silicon for solar cell applications

    NASA Technical Reports Server (NTRS)

    Dosaj, V. D.; Hunt, L. P.; Schei, A.

    1978-01-01

    The article discusses the production of solar cells from high-purity silicon. The process consists of reducing the level of impurities in the raw materials, preventing material contamination before and after entering the furnace, and performing orders-of-magnitude reduction of metal impurity concentrations. The high-purity raw materials are considered with reference to carbon reductants, silica, and graphite electrodes. Attention is also given to smelting experiments used to demonstrate, in an experimental-scale furnace, the production of high-purity SoG-Si. It is found that high-purity silicon may be produced from high-purity quartz and chemically purified charcoal in a 50-kVA arc furnace. The major contamination source is shown to be impurities from the carbon reducing materials.

  8. The evidence base for 'own label' resin-based dental restoratives.

    PubMed

    Burke, F J Trevor

    2013-01-01

    There is anecdotal evidence that sales of 'own-label' (OL) or 'private label' dental products is increasing, as dentists become more cost conscious in times of economic downturn. However, the purchase of such (less expensive) products could be a false economy if their performance falls below accepted standards. So, while the examination of a resin-based product under research conditions alone may not guarantee success, it could be considered that a material which has been subjected to testing under research conditions will demonstrate its effectiveness under laboratory conditions or reveal its shortcomings; either of these being better than the material not being examined in any way. It was therefore considered appropriate to determine the materials on which research was carried out, with particular reference to OL brands. To determine whether there is a research base behind OL resin-based restorative dental materials.

  9. Analytical characterization of recombinant hCG and comparative studies with reference product

    PubMed Central

    Thennati, Rajamannar; Singh, Sanjay Kumar; Nage, Nitin; Patel, Yena; Bose, Sandip Kumar; Burade, Vinod

    2018-01-01

    Introduction Regulatory agencies recommend a stepwise approach for demonstrating biosimilarity between a proposed biosimilar and reference biological product emphasizing for functional and structural characterization to trace if there is any difference which may impact safety and efficacy. We studied the comparative structural and biological attributes of recombinant human chorionic gonadotropin (rhCG), SB005, with reference product, Ovidrel® and Ovitrelle®. Recombiant hCG was approved in 2000 by the US Food and Drug Administration for the induction of final follicular maturation, early luteinization in infertile women as part of assisted reproductive technology program. It is also indicated for the induction of ovulation and pregnancy in ovulatory infertile patients whose cause of infertility is not due to ovarian failure. Materials and methods Primary structure was studied by intact mass analysis, peptide fingerprinting, peptide mass fingerprinting and sequence coverage analysis. Higher order structure was studied by circular dichroism, ultraviolet-visible spectroscopy, fluorescence spectroscopy, and disulfide bridge analysis. Different isoforms of reference product and SB005 were identified using capillary isoelectric focusing and capillary zone electrophoresis. Glycosylation was studied by N-glycan mapping using LC-ESI-MS, point of glycosylation, released glycan analysis using ultra performance liquid chromatography and sialic acid analysis. Product related impurities such as oligomer content analysis and oxidized impurities were studied using size exclusion chromatography and reverse phase high performance liquid chromatography, respectively. Biological activity in term of potency of reference product and SB005 was studied by in vivo analysis. Results and Conclusion In this study we have compared analytical similarity of recombinant rhCG (SB005) produced at Sun Pharmaceuticals with the reference product with respect to its primary, higher order structure, isoforms, charge variants, glycosylation, sialyation pattern, pharmacodynamic and in vivo efficacy. Our studies show that the in house produced rhCG has a high degree of structural and functional similarity with the reference product available in the market. PMID:29430170

  10. Evolution of activities in international biological standardization since the early days of the Health Organisation of the League of Nations.

    PubMed

    Sizaret, P

    1988-01-01

    The main activities in international biological standardization during the 18 years that followed the first international biological standardization meeting in London in 1921 were concerned with expressing the potencies of test preparations in comparison with reference materials. After the Second World War, however, it became clear that the testing of biological substances against international reference materials was only one among several measures for obtaining safe and potent products. The activities in international biological standardization were therefore widened so that, by the strict observance of specific manufacturing and control requirements, it was possible to gain further in safety and efficacy. At the end of 1987, 42 international requirements for biological substances were available and were being used as national requirements, sometimes after minor modification, by the majority of WHO's Member States. This is of utmost importance for the worldwide use of safe and potent biological products, including vaccines.

  11. Figures of Merit Software: Description, User's Guide, Installation Notes, Versions Description, and License Agreement

    NASA Technical Reports Server (NTRS)

    hoelzer, H. D.; Fourroux, K. A.; Rickman, D. L.; Schrader, C. M.

    2011-01-01

    Figures of Merit (FoMs) and the FoM software provide a method for quantitatively evaluating the quality of a regolith simulant by comparing the simulant to a reference material. FoMs may be used for comparing a simulant to actual regolith material, specification by stating the value a simulant s FoMs must attain to be suitable for a given application and comparing simulants from different vendors or production runs. FoMs may even be used to compare different simulants to each other. A single FoM is conceptually an algorithm that computes a single number for quantifying the similarity or difference of a single characteristic of a simulant material and a reference material and provides a clear measure of how well a simulant and reference material match or compare. FoMs have been constructed to lie between zero and 1, with zero indicating a poor or no match and 1 indicating a perfect match. FoMs are defined for modal composition, particle size distribution, particle shape distribution, (aspect ratio and angularity), and density. This TM covers the mathematics, use, installation, and licensing for the existing FoM code in detail.

  12. A bill to amend the Energy Employees Occupational Illness Compensation Program Act of 2000 to provide compensation for certain persons injured in the course of employment at the Feed Materials Production Center (commonly referred to as "Fernald") or the Piqua Organic Moderated Reactor in Ohio.

    THOMAS, 111th Congress

    Sen. Brown, Sherrod [D-OH

    2009-10-20

    Senate - 10/20/2009 Read twice and referred to the Committee on Health, Education, Labor, and Pensions. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:

  13. To amend the Energy Employees Occupational Illness Compensation Program Act of 2000 to provide compensation for certain persons injured in the course of employment at the Feed Materials Production Center (commonly referred to as "Fernald") or the Piqua Organic Moderated Reactor in Ohio.

    THOMAS, 111th Congress

    Rep. Driehaus, Steve [D-OH-1

    2009-11-03

    House - 01/04/2010 Referred to the Subcommittee on Immigration, Citizenship, Refugees, Border Security, and International Law. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:

  14. Production and Evaluation of 236gNp and Reference Materials for Naturally Occurring Radioactive Materials

    NASA Astrophysics Data System (ADS)

    Larijani, Cyrus Kouroush

    This thesis is based on the development of a radiochemical separation scheme capable of separating both 236gNp and 236Pu from a uranium target of natural isotopic composition ( 1 g uranium) and 200 MBq of fission decay products. The isobaric distribution of fission residues produced following the bombardment of a natural uranium target with a beam of 25 MeV protons has been evaluated. Decay analysis of thirteen isobarically distinct fission residues were carried out using high-resolution gamma-ray spectrometry at the UK National Physical Laboratory. Stoichiometric abundances were calculated via the determination of absolute activity concentrations associated with the longest-lived members of each isobaric chain. This technique was validated by computational modelling of likely sequential decay processes through an isobaric decay chain. The results were largely in agreement with previously published values for neutron bombardments on natural uranium at energies of 14 MeV. Higher relative yields of products with mass numbers A 110-130 were found, consistent with the increasing yield of these radionuclides as the bombarding energy is increased. Using literature values for the production cross-section for fusion of protons with uranium targets, it is estimated that an upper limit of approximately 250 Bq of activity from the 236Np ground state was produced in this experiment. Using a radiochemical separation scheme, Np and Pu fractions were separated from the produced fission decay products, with analyses of the target-based final reaction products made using Inductively Couple Plasma Mass Spectrometry (ICP-MS) and high-resolution alpha and gamma-ray spectrometry. In a separate research theme, reliable measurement of Naturally Occurring Radioactive Materials is of significance in order to comply with environmental regulations and for radiological protection purposes. The thesis describes the standardisation of three reference materials, namely Sand, Tuff and TiO2 which can serve as quality control materials to achieve traceability, method validation and instrument calibration. The sample preparation, material characterization via gamma, alpha and Inductively Coupled Plasma Mass Spectrometry (ICP-MS) and the assignment of values for both the 4n Thorium and 4n + 2 Uranium decay series are presented.

  15. Climate Change Effects of Forest Management and Substitution of Carbon-Intensive Materials and Fossil Fuels

    NASA Astrophysics Data System (ADS)

    Sathre, R.; Gustavsson, L.; Haus, S.; Lundblad, M.; Lundström, A.; Ortiz, C.; Truong, N.; Wikberg, P. E.

    2016-12-01

    Forests can play several roles in climate change mitigation strategies, for example as a reservoir for storing carbon and as a source of renewable materials and energy. To better understand the linkages and possible trade-offs between different forest management strategies, we conduct an integrated analysis where both sequestration of carbon in growing forests and the effects of substituting carbon intensive products within society are considered. We estimate the climate effects of directing forest management in Sweden towards increased carbon storage in forests, with more land set-aside for protection, or towards increased forest production for the substitution of carbon-intensive materials and fossil fuels, relative to a reference case of current forest management. We develop various scenarios of forest management and biomass use to estimate the carbon balances of the forest systems, including ecological and technological components, and their impacts on the climate in terms of cumulative radiative forcing over a 100-year period. For the reference case of current forest management, increasing the harvest of forest residues is found to give increased climate benefits. A scenario with increased set-aside area and the current level of forest residue harvest begins with climate benefits compared to the reference scenario, but the benefits cannot be sustained for 100 years because the rate of carbon storage in set-aside forests diminishes over time as the forests mature, but the demand for products and fuels remains. The most climatically beneficial scenario, expressed as reduced cumulative radiative forcing, in both the short and long terms is a strategy aimed at high forest production, high residue recovery rate, and high efficiency utilization of harvested biomass. Active forest management with high harvest level and efficient forest product utilization will provide more climate benefit, compared to reducing harvest and storing more carbon in the forest. Figure. Schematic diagram of complete modelled forest system including ecological and technological components, showing major flows of carbon.

  16. Feasibility study on production of a matrix reference material for cyanobacterial toxins.

    PubMed

    Hollingdale, Christie; Thomas, Krista; Lewis, Nancy; Békri, Khalida; McCarron, Pearse; Quilliam, Michael A

    2015-07-01

    The worldwide increase in cyanobacterial contamination of freshwater lakes and rivers is of great concern as many cyanobacteria produce potent hepatotoxins and neurotoxins (cyanotoxins). Such toxins pose a threat to aquatic ecosystems, livestock, and drinking water supplies. In addition, dietary supplements prepared from cyanobacteria can pose a risk to consumers if they contain toxins. Analytical monitoring for toxins in the environment and in consumer products is essential for the protection of public health. Reference materials (RMs) are an essential tool for the development and validation of analytical methods and are necessary for ongoing quality control of monitoring operations. Since the availability of appropriate RMs for cyanotoxins has been very limited, the present study was undertaken to examine the feasibility of producing a cyanobacterial matrix RM containing various cyanotoxins. The first step was large-scale culturing of various cyanobacterial cultures that produce anatoxins, microcystins, and cylindrospermopsins. After harvesting, the biomass was lyophilized, blended, homogenized, milled, and bottled. The moisture content and physical characteristics were assessed in order to evaluate the effectiveness of the production process. Toxin levels were measured by liquid chromatography with tandem mass spectrometry and ultraviolet detection. The reference material was found to be homogeneous for toxin content. Stability studies showed no significant degradation of target toxins over a period of 310 days at temperatures up to +40 °C except for the anatoxin-a, which showed some degradation at +40 °C. These results show that a fit-for-purpose matrix RM for cyanotoxins can be prepared using the processes and techniques applied in this work.

  17. The Marriage of Fax and Online.

    ERIC Educational Resources Information Center

    Basch, Reva

    1995-01-01

    Discusses the use of fax transmissions. Highlights include searching by fax, including online service, print and electronic publishing, and database producers; customer service, including documentation updates, new product announcements, and marketing materials; document delivery; problems; and fax messaging. (four references) (LRW)

  18. Improving Employee Performance.

    ERIC Educational Resources Information Center

    Civil Service Commission, Washington, DC. Library.

    This publication in the Personnel Bibliography Series supplements two previous bibliographies on productivity, motivation, and incentive awards and on managing human behavior. It covers materials received in the Civil Service Commission's Library during 1970 and 1971. Categories for which annotated references are provided include…

  19. Intellectual Property Materials Online/CD-ROM: What and Where.

    ERIC Educational Resources Information Center

    Thompson, N. J.

    1992-01-01

    This comprehensive review of databanks and CD-ROMs worldwide dealing with patents, trademarks, trade names, copyrights, and related legal opinions includes comments on database coverage and search features. Comparison tables of vendors' products are provided. (22 references) (EA)

  20. Reference materials and representative test materials to develop nanoparticle characterization methods: the NanoChOp project case

    NASA Astrophysics Data System (ADS)

    Roebben, Gert; Kestens, Vikram; Varga, Zoltan; Charoud-Got, Jean; Ramaye, Yannic; Gollwitzer, Christian; Bartczak, Dorota; Geißler, Daniel; Noble, James; Mazoua, Stéphane; Meeus, Nele; Corbisier, Philippe; Palmai, Marcell; Mihály, Judith; Krumrey, Michael; Davies, Julie; Resch-Genger, Ute; Kumarswami, Neelam; Minelli, Caterina; Sikora, Aneta; Goenaga-Infante, Heidi

    2015-10-01

    This paper describes the production and characteristics of the nanoparticle test materials prepared for common use in the collaborative research project NanoChOp (Chemical and optical characterisation of nanomaterials in biological systems), in casu suspensions of silica nanoparticles and CdSe/CdS/ZnS quantum dots. This paper is the first to illustrate how to assess whether nanoparticle test materials meet the requirements of a 'reference material' (ISO Guide 30:2015) or rather those of the recently defined category of 'representative test material' (ISO TS 16195:2013). The NanoChOp test materials were investigated with small-angle X-ray scattering (SAXS), dynamic light scattering (DLS) and centrifugal liquid sedimentation (CLS) to establish whether they complied with the required monomodal particle size distribution. The presence of impurities, aggregates, agglomerates and viable microorganisms in the suspensions was investigated with DLS, CLS, optical and electron microscopy and via plating on nutrient agar. Suitability of surface functionalization was investigated with attenuated total reflection Fourier transform infrared spectrometry (ATR-FTIR) and via the capacity of the nanoparticles to be fluorescently labeled or to bind antibodies. Between-unit homogeneity and stability were investigated in terms of particle size and zeta potential. This paper shows that only based on the outcome of a detailed characterization process one can raise the status of a test material to representative test material or reference material, and how this status depends on its intended use.

  1. Health effects of drinking water disinfectants and disinfection by-products

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Condie, L.W.; Bercz, J.P.

    This paper summarizes toxicological studies conducted with drinking water disinfectants. Toxicological effects, which are associated with the disinfectants themselves as well as with the by-products formed when disinfectants react with organic material present in water, are considered. The health impact of chemical reactions occurring between residual disinfectants and nutrients in the gastrointestinal tract is also discussed. 40 references, 5 tables.

  2. Policy and Technical Issues Facing a Fissile Material (Cutoff) Treaty

    DOE PAGES

    von Hippel, Frank; Mian, Zia

    2015-05-18

    We report the largest obstacle to creating nuclear weapons, starting with the ones that destroyed Hiroshima and Nagasaki, has been to make sufficient quantities of fissile materials – highly enriched uranium (HEU) and plutonium – to sustain an explosive fission chain reaction.1 Recognition of this fact has, for more than fifty years, underpinned both the support for and the opposition to adoption of an international treaty banning at a minimum the production of more fissile materials for nuclear weapons, commonly referred to as a fissile material cutoff treaty (FMCT).

  3. Supply Management Analysis of the Chilean Navy Acquisition System

    DTIC Science & Technology

    2014-12-01

    52 LIST OF REFERENCES Armada de Chile, N. (1986). Manual de Logistica de la Armada de Chile [Manual of logistics of the Chilean Navy]. Chile... transportation • Quality control • Demand and supply planning • Receiving, materials handling, and storage 11 • Material or inventory control...Order purchasing • Production planning, scheduling, and control • Warehousing and distribution • Shipping • Outbound transportation • Customer

  4. Weapon-Specific Strategic Material Estimation Process (WSSMEP)

    DTIC Science & Technology

    2014-12-01

    Whitley for his insightful review and comments. We also want to thank the editor, Mr. John Everett , and Ms. Barbara Varvaglione for production...Institute for Defense Analyses, 2013. Thomason, Jim, Jim Bell , Eleanor Schwartz, Bob Atwell, Dick Van Atta, Nicholas Karvonides, Zack Rabold, Tiki...sources for more detailed documentation material. 41 Appendix A References Thomason, James S., Robert J. Atwell, D. Sean Burnett, James P. Bell

  5. Creating a Holistic Extractables and Leachables (E&L) Program for Biotechnology Products.

    PubMed

    Li, Kim; Rogers, Gary; Nashed-Samuel, Yasser; Lee, Hans; Mire-Sluis, Anthony; Cherney, Barry; Forster, Ronald; Yeh, Ping; Markovic, Ingrid

    2015-01-01

    The risk mitigation of extractables and leachables presents significant challenges to regulators and drug manufacturers with respect to the development, as well as the lifecycle management, of drug products. A holistic program is proposed, using a science- and risk-based strategy for testing extractables and leachables from primary containers, drug delivery devices, and single-use systems for the manufacture of biotechnology products. The strategy adopts the principles and concepts from ICH Q9 and ICH Q8(R2). The strategy is phase-appropriate, progressing from extractables testing for material screening/selection/qualification through leachables testing of final products. The strategy is designed primarily to ensure patient safety and product quality of biotechnology products. The holistic program requires robust extraction studies using model solvents, with careful consideration of solvation effect, pH, ionic strength, temperature, and product-contact surface and duration. From a wide variety of process- and product-contact materials, such extraction studies have identified and quantified over 200 organic extractable compounds. The most commonly observed compounds were siloxanes, fatty acid amides, and methacrylates. Toxicology assessments were conducted on these compounds using risk-based decision analysis. Parenteral permitted daily exposure limits were derived, as appropriate, for the majority of these compounds. Analysis of the derived parenteral permitted daily exposure limits helped to establish action thresholds to target high-risk leachables in drug products on stability until expiry. Action thresholds serve to trigger quality investigations to determine potential product impact. The holistic program also evaluates the potential risk for immunogenicity. This approach for primary drug containers and delivery devices is also applicable to single-use systems when justified with a historical knowledge base and understanding of the manufacturing processes of biotechnology products. In the development of a drug product, careful consideration is given to impurities that may originate from manufacturing equipment, process components, and packaging materials. The majority of such impurities are common chemical additives used to improve the physicochemical properties of a wide range of plastic materials. Suppliers and drug manufacturers conduct studies to extract chemical additives from the plastic materials in order to screen and predict those that may leach into a drug product. In this context, the term extractables refers to a profile of extracted compounds observed in studies under harsh conditions. In contrast, the term leachables refers to those impurities that leach from the materials under real-use conditions and may be present in final drug products. The purpose of this article is to present a holistic approach that effectively minimizes the risk of leachables to patient safety and product quality. © PDA, Inc. 2015.

  6. Biophysical characterization and structure of the Fab fragment from the NIST reference antibody, RM 8671.

    PubMed

    Karageorgos, Ioannis; Gallagher, Elyssia S; Galvin, Connor; Gallagher, D Travis; Hudgens, Jeffrey W

    2017-11-01

    Monoclonal antibody pharmaceuticals are the fastest-growing class of therapeutics, with a wide range of clinical applications. To assure their safety, these protein drugs must demonstrate highly consistent purity and stability. Key to these objectives is higher order structure measurements validated by calibration to reference materials. We describe preparation, characterization, and crystal structure of the Fab fragment prepared from the NIST Reference Antibody RM 8671 (NISTmAb). NISTmAb is a humanized IgG1κ antibody, produced in murine cell culture and purified by standard biopharmaceutical production methods, developed at the National Institute of Standards and Technology (NIST) to serve as a reference material. The Fab fragment was derived from NISTmAb through papain cleavage followed by protein A based purification. The purified Fab fragment was characterized by SDS-PAGE, capillary gel electrophoresis, multi-angle light scattering, size exclusion chromatography, mass spectrometry, and x-ray crystallography. The crystal structure at 0.2 nm resolution includes four independent Fab molecules with complete light chains and heavy chains through Cys 223, enabling assessment of conformational variability and providing a well-characterized reference structure for research and engineering applications. This nonproprietary, publically available reference material of known higher-order structure can support metrology in biopharmaceutical applications, and it is a suitable platform for validation of molecular modeling studies. Published by Elsevier Ltd.

  7. Detection of nanomaterials in food and consumer products: bridging the gap from legislation to enforcement.

    PubMed

    Stamm, H; Gibson, N; Anklam, E

    2012-08-01

    This paper describes the requirements and resulting challenges for the implementation of current and upcoming European Union legislation referring to the use of nanomaterials in food, cosmetics and other consumer products. The European Commission has recently adopted a recommendation for the definition of nanomaterials. There is now an urgent need for appropriate and fit-for-purpose analytical methods in order to identify nanomaterials properly according to this definition and to assess whether or not a product contains nanomaterials. Considering the lack of such methods to date, this paper elaborates on the challenges of the legislative framework and the type of methods needed, not only to facilitate implementation of labelling requirements, but also to ensure the safety of products coming to the market. Considering the many challenges in the analytical process itself, such as interaction of nanoparticles with matrix constituents, potential agglomeration and aggregation due to matrix environment, broad variety of matrices, etc., there is a need for integrated analytical approaches, not only for sample preparation (e.g. separation from matrix), but also for the actual characterisation. Furthermore, there is an urgent need for quality assurance tools such as validated methods and (certified) reference materials, including materials containing nanoparticles in a realistic matrix (food products, cosmetics, etc.).

  8. Development of an Assessment Method for Building Materials Under Euratom Scope.

    PubMed

    de With, Govert

    2017-11-01

    In 2013, the European Commission published its basic safety standards for protection against the dangers arising from exposure to ionizing radiation (Council Directive 2013/59/Euratom)-also known as EU-BSS. As a result, the use of raw materials with potentially elevated activity concentrations such as fly ash, phosphogypsum, and slags will now fall under EU-BSS scope when applied in building materials. In light of this new policy, a variety of tools are available to assess compliance with the 1-mSv y reference level for building materials. At the heart of these tools is a gamma-spectrometric determination of the naturally occurring radionuclides Ra, Th, and K in the material of concern. As a large number of construction products contain a certain amount of the raw material that falls under the scope of the EU regulation, this policy will lead to substantial measurement of building materials that pose little radiation risk. For this reason, a method is developed to enable assessment against the 1-mSv value not on the basis of gamma-spectrometric analysis but rather based on the product's material composition. The proposed method prescribes a maximum permitted content of raw materials with potentially elevated activity concentrations in terms of a weight percentage of the end product, where the raw materials of concern are defined as those listed in Annex XIII of the EU-BSS. The permitted content is a function of the product's surface density. Therefore, a product with a low surface density of up to 25 kg m can consist of nearly 100% raw materials with potentially elevated activity concentrations, and this percentage drops to around 15% for products with a surface density of around 500 kg m. Building materials that comply with these requirements on product composition are exempt from testing, while products that do not comply must perform regular gamma-spectrometric analysis. A full validation and testing of the method is provided. In addition, the paper discusses issues relevant for regulatory implementation.

  9. 21 CFR 320.26 - Guidelines on the design of a single-dose in vivo bioavailability or bioequivalence study.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ..., DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS FOR HUMAN USE BIOAVAILABILITY AND BIOEQUIVALENCE... test product and the reference material should be administered to subjects in the fasting state, unless...

  10. Graphene-based filament material for thermal ionization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hewitt, J.; Shick, C.; Siegfried, M.

    The use of graphene oxide materials for thermal ionization mass spectrometry analysis of plutonium and uranium has been investigated. Filament made from graphene oxide slurries have been 3-D printed. A method for attaching these filaments to commercial thermal ionization post assemblies has been devised. Resistive heating of the graphene based filaments under high vacuum showed stable operation in excess of 4 hours. Plutonium ion production has been observed in an initial set of filaments spiked with the Pu 128 Certified Reference Material.

  11. Conservation and Renewable Energy Program: Bibliography, 1988 edition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vaughan, K.H.

    The 831 references covering the period 1980 through Feb. 1988, are arranged under the following: analysis and evaluation, building equipment, building thermal envelope systems and materials, community systems and cogeneration, residential conservation service, retrofit, advanced heat engine ceramics, alternative fuels, microemulsion fuels, industrial chemical heat pumps, materials for waste heat utilization, energy conversion and utilization materials, tribology, emergency energy conservation,inventions, electric energy systems, thermal storage, biofuels production, biotechnology, solar technology, geothermal, and continuous chromatography in multicomponent separations. An author index is included.

  12. Evaluation of Natural Products for Algicidal Properties

    PubMed Central

    Safferman, Robert S.; Morris, Mary-Ellen

    1962-01-01

    A procedure for the screening of antialgal substances has been described and evaluated with specific reference to microbial products. Data on the extracellular materials of 545 actinomycete and fungal isolates showed a wide distribution of agents having algicidal activities. Of these culture filtrates, 20.4% apparently had selective antagonistic effects against particular algal groups. A more comprehensive examination revealed that metabolic products from two actinomycete cultures exhibited properties that warrant further studies on their chemical and physiological characteristics. PMID:14495975

  13. Factors Affecting the Supply of Strategic Raw Materials with Particular Reference to the Aerospace Manufacturing Industry

    DTIC Science & Technology

    1984-04-01

    element, recovered from the working of many porphyry copper deposits. As copper capacity i» now far beyond requirements, molybdenum should not be in...Source» Cobalt is mostly recovered aa a by-product of copper and nickel mining but world production is highly localised. Total annual production is...aluminium alloy containing lithium, copper and magnesium is under test. Por corrosion resistance there can be an Interchange with niobium. However

  14. Second-order polynomial model to solve the least-cost lumber grade mix problem

    Treesearch

    Urs Buehlmann; Xiaoqiu Zuo; R. Edward Thomas

    2010-01-01

    Material costs when cutting solid wood parts from hardwood lumber for secondary wood products manufacturing account for 20 to 50 percent of final product cost. These costs can be minimized by proper selection of the lumber quality used. The lumber quality selection problem is referred to as the least-cost lumber grade mix problem in the industry. The objective of this...

  15. Comparison of ASTM D613 and ASTM D6890

    DTIC Science & Technology

    2016-04-01

    product , process, or service by trade name, trademark, manufacturer, or otherwise, does not necessarily constitute or imply its endorsement...state or reflect those of the United States Government or the DoA, and shall not be used for advertising or product endorsement purposes...methylnaphthalene proved to be an impractical material for reference values. The ASTM Diesel National Exchange Group ran a study and determined that

  16. Enantioseparation of omeprazole--effect of different packing particle size on productivity.

    PubMed

    Enmark, Martin; Samuelsson, Jörgen; Forssén, Patrik; Fornstedt, Torgny

    2012-06-01

    Enantiomeric separation of omeprazole has been extensively studied regarding both product analysis and preparation using several different chiral stationary phases. In this study, the preparative chiral separation of omeprazole is optimized for productivity using three different columns packed with amylose tris (3,5-dimethyl phenyl carbamate) coated macroporous silica (5, 10 and 25 μm) with a maximum allowed pressure drop ranging from 50 to 400 bar. This pressure range both covers low pressure process systems (50-100 bar) and investigates the potential for allowing higher pressure limits in preparative applications in a future. The process optimization clearly show that the larger 25 μm packing material show higher productivity at low pressure drops whereas with increasing pressure drops the smaller packing materials have substantially higher productivity. Interestingly, at all pressure drops, the smaller packing material result in lower solvent consumption (L solvent/kg product); the higher the accepted pressure drop, the larger the gain in reduced solvent consumption. The experimental adsorption isotherms were not identical for the different packing material sizes; therefore all calculations were recalculated and reevaluated assuming identical adsorption isotherms (with the 10 μm isotherm as reference) which confirmed the trends regarding productivity and solvent consumption. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. Surface design methodology - challenge the steel

    NASA Astrophysics Data System (ADS)

    Bergman, M.; Rosen, B.-G.; Eriksson, L.; Anderberg, C.

    2014-03-01

    The way a product or material is experienced by its user could be different depending on the scenario. It is also well known that different materials and surfaces are used for different purposes. When optimizing materials and surface roughness for a certain something with the intention to improve a product, it is important to obtain not only the physical requirements, but also the user experience and expectations. Laws and requirements of the materials and the surface function, but also the conservative way of thinking about materials and colours characterize the design of medical equipment. The purpose of this paper is to link the technical- and customer requirements of current materials and surface textures in medical environments. By focusing on parts of the theory of Kansei Engineering, improvements of the companys' products are possible. The idea is to find correlations between desired experience or "feeling" for a product, -customer requirements, functional requirements, and product geometrical properties -design parameters, to be implemented on new improved products. To be able to find new materials with the same (or better) technical requirements but a higher level of user stimulation, the current material (stainless steel) and its surface (brushed textures) was used as a reference. The usage of focus groups of experts at the manufacturer lead to a selection of twelve possible new materials for investigation in the project. In collaboration with the topical company for this project, three new materials that fulfil the requirements -easy to clean and anti-bacterial came to be in focus for further investigation in regard to a new design of a washer-disinfector for medical equipment using the Kansei based Clean ability approach CAA.

  18. Effect of microaerobic fermentation in preprocessing fibrous lignocellulosic materials.

    PubMed

    Alattar, Manar Arica; Green, Terrence R; Henry, Jordan; Gulca, Vitalie; Tizazu, Mikias; Bergstrom, Robby; Popa, Radu

    2012-06-01

    Amending soil with organic matter is common in agricultural and logging practices. Such amendments have benefits to soil fertility and crop yields. These benefits may be increased if material is preprocessed before introduction into soil. We analyzed the efficiency of microaerobic fermentation (MF), also referred to as Bokashi, in preprocessing fibrous lignocellulosic (FLC) organic materials using varying produce amendments and leachate treatments. Adding produce amendments increased leachate production and fermentation rates and decreased the biological oxygen demand of the leachate. Continuously draining leachate without returning it to the fermentors led to acidification and decreased concentrations of polysaccharides (PS) in leachates. PS fragmentation and the production of soluble metabolites and gases stabilized in fermentors in about 2-4 weeks. About 2 % of the carbon content was lost as CO(2). PS degradation rates, upon introduction of processed materials into soil, were similar to unfermented FLC. Our results indicate that MF is insufficient for adequate preprocessing of FLC material.

  19. Learning Resources Evaluations Manual.

    ERIC Educational Resources Information Center

    Nunes, Evelyn H., Ed.

    This manual contains evaluations of 196 instructional products listed in Virginia's Adult Basic Education Curricula Resource Catalog. It is intended as a convenient reference manual for making informed decisions concerning materials for adult learners in adult basic education, English-as-a-Second-Language instruction, and general educational…

  20. Winter Roadway Maintenance Material Enhancers (Field) Evaluation

    DOT National Transportation Integrated Search

    2018-04-06

    In this study, the performance and cost analysis of four deicers products, i.e., Aqua Salina (AS), Beet Heet (BH), Green Blast (GB), Magic Minus Zero (MMZ), and two references, Rock Salt (RS) and/or Salt Brine (SB) were evaluated through parking lot ...

  1. Concerted Creativity: Emergence in the Socio-(Im)Material and Intangible Practice of Making Music.

    PubMed

    Hvidtfeldt, Dan Lund

    2018-06-01

    The purpose of this article is to explore how the basic conception of 'emergence' informs the study of creativity as a socio-material practice. Initially, the article explicates how creative processes, products and performances involve not only tangible, but also intangible and social elements. Secondly, the theoretical conception of creativity as socio-material and the general philosophical notion of emergence are introduced. Inspired by the idea that a 'whole' is other than the sum of its 'parts' and by examples primarily from the world of music, the article argues that the relationship between subject and object - the main analytical focus of studies on creativity as a socio-material practice - is fundamentally embedded in an emergent process. The article concludes by highlighting how emergence theory acknowledges the performance or product as an intangible material for creative processes of musicians, and that studies of the socio-materiality of creative practices clearly involving tangible, intangible and social elements must refer to the emergent process through which the creative product or performance evolves meaning. The theoretical framework suggested is relevant for researchers interested in exploring how materials, social settings and physical environments are involved in creative processes.

  2. The NISTmAb Reference Material 8671 lifecycle management and quality plan.

    PubMed

    Schiel, John E; Turner, Abigail

    2018-03-01

    Comprehensive analysis of monoclonal antibody therapeutics involves an ever expanding cadre of technologies. Lifecycle-appropriate application of current and emerging techniques requires rigorous testing followed by discussion between industry and regulators in a pre-competitive space, an effort that may be facilitated by a widely available test metric. Biopharmaceutical quality materials, however, are often difficult to access and/or are protected by intellectual property rights. The NISTmAb, humanized IgG1κ Reference Material 8671 (RM 8671), has been established with the intent of filling that void. The NISTmAb embodies the quality and characteristics of a typical biopharmaceutical product, is widely available to the biopharmaceutical community, and is an open innovation tool for development and dissemination of results. The NISTmAb lifecyle management plan described herein provides a hierarchical strategy for maintenance of quality over time through rigorous method qualification detailed in additional submissions in the current publication series. The NISTmAb RM 8671 is a representative monoclonal antibody material and provides a means to continually evaluate current best practices, promote innovative approaches, and inform regulatory paradigms as technology advances. Graphical abstract The NISTmAb Reference Material (RM) 8671 is intended to be an industry standard monoclonal antibody for pre-competitive harmonization of best practices and designing next generation characterization technologies for identity, quality, and stability testing.

  3. Production of highly-enriched 134Ba for a reference material for isotope dilution mass spectrometry measurements

    DOE PAGES

    Horkley, J. J.; Carney, K. P.; Gantz, E. M.; ...

    2015-03-17

    Isotope dilution mass spectrometry (IDMS) is an analytical technique capable of providing accurate and precise quantitation of trace isotope abundance and assay providing measurement uncertainties below 1 %. To achieve these low uncertainties, the IDMS method ideally utilizes chemically pure “spike” solutions that consist of a single highly enriched isotope that is well-characterized relating to the abundance of companion isotopes and concentration in solution. To address a current demand for accurate 137Cs/137Ba ratio measurements for “age” determination of radioactive 137Cs sources, Idaho National Laboratory (INL) is producing enriched 134Ba isotopes that are tobe used for IDMS spikes to accurately determinemore » 137Ba accumulation from the decay of 137Cs. The final objective of this work it to provide a homogenous set of reference materials that the National Institute of Standards and Technology can certify as standard reference materials used for IDMS. The process that was developed at INL for the separation and isolation of Ba isotopes, chemical purification of the isotopes in solution, and the encapsulation of the materials will be described.« less

  4. Process optimization at small and medium-sized enterprises: production of small and medium-sized batches

    NASA Astrophysics Data System (ADS)

    Stettmer, J.

    2017-06-01

    The organization of a company needs to refer to the production process and especially to the number of employees. Many enterprises which are growing, are primarily focused on the development of the technology and not on the development of the organization. This ends up in an increase of the turnover but in a reduced margin. For the development of the organization in growing companies there are two things necessary. The development of the staff to work systematically and coordinated in teams as well as the flow of the information and material between the teams. ERP - systems are required to install the material and information flow especially in the work floor. Unfortunately many enterprises don't use the ERP-systems to plan and control the material and information flow very detailed. In companies where the control of the material and information flow was installed, it could be demonstrated that the margin increased analog to it. The requirements to the development of the organization based on the increasing number of the employees are basically the same for most of the production processes like the production of metal sheet housings or the production of mirrors and lenses.

  5. Sulfur recirculation for increased electricity production in Waste-to-Energy plants.

    PubMed

    Andersson, Sven; Blomqvist, Evalena W; Bäfver, Linda; Jones, Frida; Davidsson, Kent; Froitzheim, Jan; Karlsson, Martin; Larsson, Erik; Liske, Jesper

    2014-01-01

    Sulfur recirculation is a new technology for reducing boiler corrosion and dioxin formation. It was demonstrated in full-scale tests at a Waste to Energy plant in Göteborg (Sweden) during nearly two months of operation. Sulfur was recirculated as sulfuric acid from the flue gas cleaning back to the boiler, thus creating a sulfur loop. The new technology was evaluated by extensive measurement campaigns during operation under normal conditions (reference case) and operation with sulfur recirculation. The chlorine content of both fly ash and boiler ash decreased and the sulfur content increased during the sulfur recirculation tests. The deposit growth and the particle concentration decreased with sulfur recirculation and the dioxin concentration (I-TEQ) of the flue gas was reduced by approximately 25%. Sulfuric acid dew point measurements showed that the sulfuric acid dosage did not lead to elevated SO3 concentrations, which may otherwise induce low temperature corrosion. In the sulfur recirculation corrosion probe exposures, the corrosion rate decreased for all tested materials (16Mo3, Sanicro 28 and Inconel 625) and material temperatures (450 °C and 525 °C) compared to the reference exposure. The corrosion rates were reduced by 60-90%. Sulfur recirculation prevented the formation of transition metal chlorides at the metal/oxide interface, formation of chromate and reduced the presence of zinc in the corrosion products. Furthermore, measured corrosion rates at 525 °C with sulfur recirculation in operation were similar or lower compared to those measured at 450 °C material temperature in reference conditions, which corresponds to normal operation at normal steam temperatures. This implies that sulfur recirculation allows for higher steam data and electricity production without increasing corrosion. Copyright © 2013 The Authors. Published by Elsevier Ltd.. All rights reserved.

  6. Global stocks of selected mineral-based commodities

    USGS Publications Warehouse

    Wilburn, David R.; Bleiwas, Donald I.; Karl, Nick A.

    2016-12-05

    IntroductionThe U.S. Geological Survey, National Minerals Information Center, analyzes mineral and metal supply chains by identifying and describing major components of mineral and material flows from ore extraction, through intermediate forms, to a final product. This report focuses on an important component of the world’s supply chain: the amounts and global distribution of major consumer, producer, and exchange stocks of selected mineral commodities. In this report, the term “stock” is used instead of “inventory” and refers to accumulations of mined ore, intermediate products, and refined mineral-based commodities that are in a form that meets the agreed-upon specifications of a buyer or processor of intermediate products. These may include certain ores such as bauxite, concentrates, smelter products, and refined metals. Materials sometimes referred to as inventory for accounting purposes, such as ore contained in a deposit or in a leach pile, or materials that need to be further processed before they can be shipped to a consumer, are not considered. Stocks may be held (owned) by consumers, governments, investors, producers, and traders. They may serve as (1) a means to achieve economic, social, and strategic goals through government policies; (2) a secure source of supply to meet demand and to mitigate potential shortages in the supply chain; (3) a hedge to mitigate price volatility; and (4) vehicles for speculative investment.The paucity and uneven reliability of data for stocks of ores and concentrates and for material held by producers, consumers, and merchants hinder the accurate estimating of the size and distribution of this portion of the supply chain for certain commodities. This paper reviews the more visible stocks held in commodity exchange warehouses distributed throughout the world.

  7. Workshop on standards in biomass for energy and chemicals: proceedings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Milne, T.A.

    1984-11-01

    In the course of reviewing standards literature, visiting prominent laboratories and research groups, attending biomass meetings and corresponding widely, a whole set of standards needs was identified, the most prominent of which were: biomass standard reference materials, research materials and sample banks; special collections of microorganisms, clonal material, algae, etc.; standard methods of characterization of substrates and biomass fuels; standard tests and methods for the conversion and end-use of biomass; standard protocols for the description, harvesting, preparation, storage, and measurement of productivity of biomass materials in the energy context; glossaries of terms; development of special tests for assay of enzymaticmore » activity and related processes. There was also a recognition of the need for government, professional and industry support of concensus standards development and the dissemination of information on standards. Some 45 biomass researchers and managers met with key NBS staff to identify and prioritize standards needs. This was done through three working panels: the Panel on Standard Reference Materials (SRM's), Research Materials (RM's), and Sample Banks; the Panel on Production and Characterization; and the Panel on Tests and Methods for Conversion and End Use. This report gives a summary of the action items in standards development recommended unanimously by the workshop attendees. The proceedings of the workshop, and an appendix, contain an extensive written record of the findings of the workshop panelists and others regarding presently existing standards and standards issues and needs. Separate abstracts have been prepared for selected papers for inclusion in the Energy Database.« less

  8. Production of a Novel OX40 Ligand for Clinical Use

    DTIC Science & Technology

    2012-10-01

    inhibitory to the detection of mycoplasma. 19.0 TECHNICAL REFERENCES 19.1 Barile , Michael F. and McGarrity, Gerard J. (1983). "Isolation of Mycoplasmas from...Edition, Section 2.6.7, Mycoplasmas. 19.4 McGarrity, Gerard J. and Barile , Michael F. (1983). "Use of Indicator Cell Lines for Recovery and...test material will be discarded following study completion unless otherwise requested by Sponsor. 20.0 REFERENCES 20.1 Barile , Michael F. and

  9. Polymerase chain reaction technology as analytical tool in agricultural biotechnology.

    PubMed

    Lipp, Markus; Shillito, Raymond; Giroux, Randal; Spiegelhalter, Frank; Charlton, Stacy; Pinero, David; Song, Ping

    2005-01-01

    The agricultural biotechnology industry applies polymerase chain reaction (PCR) technology at numerous points in product development. Commodity and food companies as well as third-party diagnostic testing companies also rely on PCR technology for a number of purposes. The primary use of the technology is to verify the presence or absence of genetically modified (GM) material in a product or to quantify the amount of GM material present in a product. This article describes the fundamental elements of PCR analysis and its application to the testing of grains. The document highlights the many areas to which attention must be paid in order to produce reliable test results. These include sample preparation, method validation, choice of appropriate reference materials, and biological and instrumental sources of error. The article also discusses issues related to the analysis of different matrixes and the effect they may have on the accuracy of the PCR analytical results.

  10. Alternative aircraft anti-icing formulations with reduced aquatic toxicity and biochemical oxygen demand

    USGS Publications Warehouse

    Gold, Harris; Joback, Kevin; Geis, Steven; Bowman, George; Mericas, Dean; Corsi, Steven R.; Ferguson, Lee

    2010-01-01

    The current research was conducted to identify alternative aircraft and pavement deicer and anti-icer formulations with improved environmental characteristics compared to currently used commercial products (2007). The environmental characteristics of primary concern are the biochemical oxygen demand (BOD) and aquatic toxicity of the fully formulated products. Except when the distinction among products is necessary for clarity, “deicer” will refer to aircraft-deicing fluids (ADFs), aircraft anti-icing fluids (AAFs), and pavementdeicing materials (PDMs).

  11. RIM as the data base management system for a material properties data base

    NASA Technical Reports Server (NTRS)

    Karr, P. H.; Wilson, D. J.

    1984-01-01

    Relational Information Management (RIM) was selected as the data base management system for a prototype engineering materials data base. The data base provides a central repository for engineering material properties data, which facilitates their control. Numerous RIM capabilities are exploited to satisfy prototype data base requirements. Numerical, text, tabular, and graphical data and references are being stored for five material types. Data retrieval will be accomplished both interactively and through a FORTRAN interface. The experience gained in creating and exercising the prototype will be used in specifying requirements for a production system.

  12. 29 CFR 520.300 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... representative. Shoe manufacturing industry means the manufacture or partial manufacture of footwear from any... manufacturing also includes the manufacture of heels from any material except molded rubber, but not including... industry means the manufacturing of the following products as referred to in subpart D of this part: (1...

  13. Laser/Optical Data Base Products: Evaluation and Selection.

    ERIC Educational Resources Information Center

    Nicholls, Paul Travis

    1988-01-01

    The practical advice for the evaluation of laser/optical data disk materials (e.g., CD-ROM) is based on a review of the relevant literature. An evaluation framework is outlined and collection development tools and sources of published reviews are identified. (34 references) (Author/CLB)

  14. A Reference Method for Measuring Emissions of SVOCs in Small Chambers

    EPA Science Inventory

    Semivolatile organic compounds (SVOCs) are indoor air pollutants that may may have significant adverse effects on human health, and emission of SVOCs from building materials and consumer products is of growing concern. Few chamber studies have been conducted due to the challenge...

  15. Expanding Rational Molecular Design beyond Pharma: Metrics to Guide Safer Chemical Design

    EPA Science Inventory

    The demand for safer, healthier and sustainable products, materials and processes has been increasing over the past several years. Differentiating which chemicals are relatively less hazardous than others, often referred to as “greener” or “sustainable, demands a comprehensive, h...

  16. Energy Materials: A Classified Listing

    ERIC Educational Resources Information Center

    Library Journal, 1978

    1978-01-01

    This bibliography includes 615 books and audiovisual products on energy and related topics. Books are listed in the following categories: reference, general, alternative sources, citizen action, coal, conservation and ecology, economics and politics, electricity, gas, geothermal, nuclear power, oil, solar, water, wind, and juveniles. A/V materials…

  17. Expanding Rational Molecular Design beyond Pharma: Metrics toGuide Safer Chemical Design

    EPA Science Inventory

    The demand for safer, healthier and sustainable products, materials and processes has been increasing over the past several years. Differentiating which chemicals are relatively less hazardous than others, often referred to as “greener” or “sustainable, demands a comprehensive, h...

  18. Decentralized solar photovoltaic energy systems

    NASA Astrophysics Data System (ADS)

    Krupka, M. C.

    1980-09-01

    Emphasis was placed upon the selection and use of a model residential photovoltaic system to develop and quantify the necessary data. The model consists of a reference home located in Phoenix, AZ utilizing a unique solar cell array roof shingle combination. Silicon solar cells, rated at 13.5 percent efficiency at 28 C and 100 mW/sq cm insolation are used to generate 10 kW (peak). An all electric home is considered with lead acid battery storage, DC AC inversion and utility backup. The reference home is compared to others in regions of different insolation. It is suggested that solar cell materials production and fabrication may have the major environmental impact when comparing all facets of photovoltaic system usage. Fabrication of the various types of solar cell systems involves the need, handling, and transportation of many toxic and hazardous chemicals with attendant health and safety impacts. Increases in production of such materials as lead, antimony, sulfuric acid, copper, plastics, cadmium and gallium will be required should large scale usage of photovoltaic systems be implemented.

  19. Raman Barcode for Counterfeit Drug Product Detection.

    PubMed

    Lawson, Latevi S; Rodriguez, Jason D

    2016-05-03

    Potential infiltration of counterfeit drug products-containing the wrong or no active pharmaceutical ingredient (API)-into the bona fide drug supply poses a significant threat to consumers worldwide. Raman spectroscopy offers a rapid, nondestructive avenue to screen a high throughput of samples. Traditional qualitative Raman identification is typically done with spectral correlation methods that compare the spectrum of a reference sample to an unknown. This is often effective for pure materials but is quite challenging when dealing with drug products that contain different formulations of active and inactive ingredients. Typically, reliable identification of drug products using common spectral correlation algorithms can only be made if the specific product under study is present in the library of reference spectra, thereby limiting the scope of products that can be screened. In this paper, we introduce the concept of the Raman barcode for identification of drug products by comparing the known peaks in the API reference spectrum to the peaks present in the finished drug product under study. This method requires the transformation of the Raman spectra of both API and finished drug products into a barcode representation by assigning zero intensity to every spectral frequency except the frequencies that correspond to Raman peaks. By comparing the percentage of nonzero overlap between the expected API barcode and finished drug product barcode, the identity of API present can be confirmed. In this study, 18 approved finished drug products and nine simulated counterfeits were successfully identified with 100% accuracy utilizing this method.

  20. Effective dose evaluation of NORM-added consumer products using Monte Carlo simulations and the ICRP computational human phantoms.

    PubMed

    Lee, Hyun Cheol; Yoo, Do Hyeon; Testa, Mauro; Shin, Wook-Geun; Choi, Hyun Joon; Ha, Wi-Ho; Yoo, Jaeryong; Yoon, Seokwon; Min, Chul Hee

    2016-04-01

    The aim of this study is to evaluate the potential hazard of naturally occurring radioactive material (NORM) added consumer products. Using the Monte Carlo method, the radioactive products were simulated with ICRP reference phantom and the organ doses were calculated with the usage scenario. Finally, the annual effective doses were evaluated as lower than the public dose limit of 1mSv y(-1) for 44 products. It was demonstrated that NORM-added consumer products could be quantitatively assessed for the safety regulation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Initial Calibration of the AEDC Impulse Tunnel

    DTIC Science & Technology

    1996-08-01

    material characteristics required are a high yield strength, a low coefficient of expansion, and a high hardness. The calculations in this section were...Qualified users may obtain copies of this report from the Defense Technical Information Center. References to named commercial products in this...report are not to be considered in any sense as an endorsement of the product by the United States Air Force or the Government. This report has been

  2. Lunar Regolith Simulant Materials: Recommendations for Standardization, Production, and Usage

    NASA Technical Reports Server (NTRS)

    Sibille, L.; Carpenter, P.; Schlagheck, R.; French, R. A.

    2006-01-01

    Experience gained during the Apollo program demonstrated the need for extensive testing of surface systems in relevant environments, including regolith materials similar to those encountered on the lunar surface. As NASA embarks on a return to the Moon, it is clear that the current lunar sample inventory is not only insufficient to support lunar surface technology and system development, but its scientific value is too great to be consumed by destructive studies. Every effort must be made to utilize standard simulant materials, which will allow developers to reduce the cost, development, and operational risks to surface systems. The Lunar Regolith Simulant Materials Workshop held in Huntsville, AL, on January 24 26, 2005, identified the need for widely accepted standard reference lunar simulant materials to perform research and development of technologies required for lunar operations. The workshop also established a need for a common, traceable, and repeatable process regarding the standardization, characterization, and distribution of lunar simulants. This document presents recommendations for the standardization, production and usage of lunar regolith simulant materials.

  3. AmO 2 Analysis for Analytical Method Testing and Assessment: Analysis Support for AmO 2 Production

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuhn, Kevin John; Bland, Galey Jean; Fulwyler, James Brent

    Americium oxide samples will be measured for various analytes to support AmO 2 production. The key analytes that are currently requested by the Am production customer at LANL include total Am content, Am isotopics, Pu assay, Pu isotopics, and trace element content including 237Np content. Multiple analytical methods will be utilized depending on the sensitivity, accuracy and precision needs of the Am matrix. Traceability to the National Institute of Standards and Technology (NIST) will be achieved, where applicable, by running NIST traceable quality control materials. This given that there are no suitable AmO 2 reference materials currently available for requestedmore » analytes. The primary objective is to demonstrate the suitability of actinide analytical chemistry methods to support AmO 2 production operations.« less

  4. Application of GRA for Sustainable Material Selection and Evaluation Using LCA

    NASA Astrophysics Data System (ADS)

    Jayakrishna, Kandasamy; Vinodh, Sekar; Sakthi Sanghvi, Vijayaselvan; Deepika, Chinadurai

    2016-07-01

    Material selection is identified as a successful key parameter in establishing any product to be sustainable, considering its end of life (EoL) characteristics. An accurate understanding of expected service conditions and environmental considerations are crucial in the selection of material plays a vital role with overwhelming customer expectations and stringent laws. Therefore, this article presents an integrated approach for sustainable material selection using grey relational analysis (GRA) considering the EoL disposal strategies with respect to an automotive product. GRA, an impact evaluation model measures the degree of similarity between the comparability (choice of material) sequence and reference (EoL strategies) sequence based on the relational grade. The ranking result shows that the outranking relationships in the order, ABS-REC > PP-INC > AL-REM > PP-LND > ABS-LND > ABS-INC > PU-LND > AL-REC > AL-LND > PU-INC > AL-INC. The best sustainable material selected was ABS and recycling was selected as the best EoL strategy with the grey relational value of 2.43856. The best material selected by this approach, ABS was evaluated for its viability using life cycle assessment and the estimated impacts also proved the practicability of the selected material highlighting the focus on dehumidification step in the manufacturing of the case product using this developed multi-criteria approach.

  5. Practical application of thermoreversibly Cross-linked rubber products

    NASA Astrophysics Data System (ADS)

    Polgar, L. M.; Picchioni, F.; de Ruiter, E.; van Duin, M.

    2017-07-01

    Currently, rubber products cannot simply be reprocessed after their product life, due to the irreversible cross-linking methods traditionally applied. The purpose of this work is to investigate how thermoreversible cross-linking of rubbers via Diels Alder chemistry can be used for the development of recyclable rubber products. Unfortunately, the applicability of the thermoreversible EPM-g-furan/BM system appears to be limited to room temperature applications, because of the rapid deterioration of the compression set at elevated temperatures compared to irreversibly cross-linked EPM. However, the use of EPM rubber modified with thiophene or cyclopentadiene moieties may extend the temperature application range and results in rubber products with acceptable properties. Finally, rubber products generally comprise fillers such as silica, carbon black or fibers. In this context, the reinforcing effect of short cut aramid fibers on the material properties of the newly developed thermoreversibly cross-linked EPM rubbers was also studied. The material properties of the resulting products were found to be comparable to those of a fiber reinforced, peroxide cured reference sample.

  6. 48 CFR 52.211-6 - Brand name or equal.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...) Brand name, if any; and (ii) Make or model number; (3) Include descriptive literature such as illustrations, drawings, or a clear reference to previously furnished descriptive data or information available... product to make it conform to the solicitation requirements. Mark any descriptive material to clearly show...

  7. 48 CFR 52.211-6 - Brand name or equal.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...) Brand name, if any; and (ii) Make or model number; (3) Include descriptive literature such as illustrations, drawings, or a clear reference to previously furnished descriptive data or information available... product to make it conform to the solicitation requirements. Mark any descriptive material to clearly show...

  8. 48 CFR 52.211-6 - Brand name or equal.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...) Brand name, if any; and (ii) Make or model number; (3) Include descriptive literature such as illustrations, drawings, or a clear reference to previously furnished descriptive data or information available... product to make it conform to the solicitation requirements. Mark any descriptive material to clearly show...

  9. 48 CFR 52.211-6 - Brand name or equal.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...) Brand name, if any; and (ii) Make or model number; (3) Include descriptive literature such as illustrations, drawings, or a clear reference to previously furnished descriptive data or information available... product to make it conform to the solicitation requirements. Mark any descriptive material to clearly show...

  10. 48 CFR 52.211-6 - Brand name or equal.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...) Brand name, if any; and (ii) Make or model number; (3) Include descriptive literature such as illustrations, drawings, or a clear reference to previously furnished descriptive data or information available... product to make it conform to the solicitation requirements. Mark any descriptive material to clearly show...

  11. Recycling History: A CD-ROM Project on the Cheap.

    ERIC Educational Resources Information Center

    McLachlan, Robin; Messing, John

    1994-01-01

    Reports on CD-ROM product that combines reference and archival material in a low-cost integrated multimedia format. Maintains that, while this project focuses on the Battle of Gallipoli in World War I, the purpose, techniques, and processes can be transferred to other historical topics. (CFR)

  12. Non-Formal Education and Agriculture: A Selected Annotated Bibliography. Annotated Bibliography #10.

    ERIC Educational Resources Information Center

    Sullivan, Karen Collamore; And Others

    Intended for those actively engaged in nonformal education for development, this annotated bibliography contains approximately 300 references to documents that highlight issues concerning food production, distribution, and consumption. It also demonstrates education's role in enhancing developmental efforts to alleviate world hunger. Materials are…

  13. The use of reference materials in quality assurance programmes in food microbiology laboratories.

    PubMed

    In't Veld, P H

    1998-11-24

    Nine different reference materials (RMs) for use in food and water microbiology have been developed with the support of the European Commission (EC). The production process of RMs is based on spray drying bacteria suspended in milk. The highly contaminated milk powder (HCMP) obtained is mixed with sterile milk powder to achieve the desired level of contamination and is subsequently filled into gelatine capsules. The HCMP may need to be stabilised by storage for more than a year before a stable RM can be prepared. The HCMP are mixed with sterile milk powder using a pestle and mortar in order to produce homogeneous RMs. For routine use of RMs Shewhart control charts can be produced. Based on log10 transformed counts, control limits are calculated. Rules for the interpretation of results facilitate the detection of out of control situations. Besides RMs there are also CRMs (Certified Reference Materials) that are certified by the EC Community Bureau of Reference (BCR) and are intended for occasional use. Based on the BCR certificate, user tables are produced presenting the 95% confidence limits for the number of capsules likely to be examined in practice. Also power analysis is made to indicate the minimum difference between the certified value and the observed geometric mean value in relation to the number of capsules examined.

  14. Homogeneity of the geochemical reference material BRP-1 (paraná basin basalt) and assessment of minimum mass

    USGS Publications Warehouse

    Cotta, Aloisio J. B.; Enzweiler, Jacinta; Wilson, Stephen A.; Perez, Carlos A.; Nardy, Antonio J. R.; Larizzatti, Joao H.

    2007-01-01

    Reference materials (RM) are required for quantitative analyses and their successful use is associated with the degree of homogeneity, and the traceability and confidence limits of the values established by characterisation. During the production of a RM, the chemical characterisation can only commence after it has been demonstrated that the material has the required level of homogeneity. Here we describe the preparation of BRP-1, a proposed geochemical reference material, and the results of the tests to evaluate its degree of homogeneity between and within bottles. BRP-1 is the first of two geochemical RM being produced by Brazilian institutions in collaboration with the United States Geological Survey (USGS) and the International Association of Geoanalysts (IAG). Two test portions of twenty bottles of BRP-1 were analysed by wavelength dispersive-XRF spectrometry and major, minor and eighteen trace elements were determined. The results show that for most of the investigated elements, the units of BRP-1 were homogeneous at conditions approximately three times more rigorous than those strived for by the test of “sufficient homogeneity”. Furthermore, the within bottle homogeneity of BRP-1 was evaluated using small beam (1 mm2) synchrotron radiation XRF spectrometry and, for comparison, the USGS reference materials BCR-2 and GSP-2 were also evaluated. From our data, it has been possible to assign representative minimum masses for some major constituents (1 mg) and for some trace elements (1-13 mg), except Zr in GSP-2, for which test portions of 74 mg are recommended.

  15. Effect of Transitioning from Standard Reference Material 2806a to Standard Reference Material 2806b for Light Obscuration Particle Countering

    DTIC Science & Technology

    2016-04-01

    Reference Material 2806b for Light Obscuration Particle Countering April 2016 UNCLASSIFIED UNCLASSIFIED Joel Schmitigal 27809 Standard Form 298 (Rev...Standard Reference Material 2806b for Light Obscuration Particle Countering 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6...Reference Material 2806a to Standard Reference Material 2806b for Light Obscuration Particle Countering Joel Schmitigal Force Projection

  16. Database of natural matrix reference materials (NMRM) for organic constituents.

    PubMed

    Iyengar, G V; Bleise, A R

    2001-06-01

    The International Atomic Energy Agency maintains a database of internationally available certified reference materials (CRM) of natural matrices. This database is periodically updated, and presently documents nearly 25,000 measurands in 1,700 materials. The organic constituents are classified in five major groups of analytes aliphatic and aromatic hydrocarbons (A), chlorinated hydrocarbons (B), pesticides (C), organometallic compounds (D) and other organic constituents (nutrients, etc.) (E). The matrices include natural materials such as body fluids, food products, soils, and sediments, terrestrial (e.g. plants), and anthropogenic products (e.g. dust, fly ash). These five organic groups of analytes encompass more than 2000 measurands for 420 different analytes in 230 materials. Of these measurands, 1,682 (68%) are certified, and 768 (32%) are provided as informational values. Within each major group of analytes, measurands reported as informational values accounted for: A (35%); B (35%); C (26%); D (10%), and E (22%). The high proportion of informational values (i.e. non-certified values) for A, B, and C, compares well with a similar but undesirable situation faced in the nineteen-seventies in the inorganic area when simultaneous multielement techniques became available. In the case of D and E, it appears that mostly targeted analytes are measured, leading to a cohesive certification profile. Although the IAEA database is not equally comprehensive for all groups of analytes cited above, it can still serve as an useful indicator of the status of organic constituents in RMs.

  17. Are claims made in orthodontic journal advertisements evidence-supported?

    PubMed

    Livas, Christos; Kouskoura, Thaleia; Ren, Yijin; Katsaros, Christos; Pandis, Nikolaos

    2015-03-01

    To examine the supporting evidence of advertisements published in six leading orthodontic journals. The 2012-2013 printed issues of American Journal of Orthodontics and Dentofacial Orthopedics, Australian Orthodontic Journal, Journal of Orthodontics, European Journal of Orthodontics, Journal of Clinical Orthodontics, and Journal of Orofacial Orthopedics were screened for advertisements implying superior performance compared with competitor products. Advertisements were classified according to type of product, availability, and currency of supporting references. A total of 99 unique advertisements claiming clinical benefit or superiority were identified. The overwhelming majority of the identified advertisements promoted appliance products (62.6%), orthodontic materials (14.1%), and dental operatory equipment, including imaging systems (12.1%). Advertisements were found to provide references or not regardless of the product type. Half of the advertisements referred to at least one peer-reviewed publication, whereas unpublished studies were cited by 25% of the advertisements. Most of the referenced articles were published within the past 5 years. The scientific background of advertisements in the orthodontic literature appears limited. While surveillance of journal advertising needs to be regulated, clinicians are urged to critically appraise the claims being made in orthodontic print advertisements by consulting the associated existing evidence.

  18. Women in American Agriculture, a Selected Bibliography. Library List 103.

    ERIC Educational Resources Information Center

    National Agricultural Library (USDA), Washington, DC.

    More than 250 citations of materials about women in agriculture in the U.S. are contained in this partially annotated bibliography. It covers women engaged as landowners, farm managers, agricultural laborers and working in such agricultural industries as beekeeping, silk culture, and butter production. Other references concern women in…

  19. Basic Principles of Animal Science. Reprinted.

    ERIC Educational Resources Information Center

    Florida State Dept. of Education, Tallahassee.

    The reference book is designed to fulfill the need for organized subject matter dealing with basic principles of animal science to be incorporated into the high school agriculture curriculum. The material presented is scientific knowledge basic to livestock production. Five units contain specific information on the following topics: anatomy and…

  20. 40 CFR 59.110 - Incorporations by Reference.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Register. (1) ASTM D 1613-96, Standard Test Method for Acidity in Volatile Solvents and Chemical Intermediates Used in Paint, Varnish, Lacquer, and Related Products, IBR approved for § 59.104(d). (2) ASTM D... Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, West Conshohocken, PA, 19428, telephone...

  1. 75 FR 47504 - Voluntary Education Programs

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-06

    ... in a material way the economy; a section of the economy; productivity; competition; jobs; the... Reform Act'' It has been certified that 32 CFR part 68 does not contain a Federal mandate that may result... successful job performance and new learning. Also referred to as functional or basic skills. Active Guard and...

  2. 40 CFR 60.17 - Incorporations by reference.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (C267-01), U.S. EPA, Research Triangle Park, NC or at the National Archives and Records Administration... Testing and Materials (ASTM), 100 Barr Harbor Drive, Post Office Box C700, West Conshohocken, PA 19428...) ASTM D86-96, Standard Test Method for Distillation of Petroleum Products (Approved April 10, 1996), IBR...

  3. Learning about Global Interdependence: An Area-Value Mapping Exercise.

    ERIC Educational Resources Information Center

    Crooker, Richard A.

    1990-01-01

    Presents a lesson for secondary school students that uses an area value map to increase student understanding about the geography of international drug production and consumption. Provides a list of necessary classroom materials, suggested background readings for students, procedures to be followed, and a bibliography of references. (DB)

  4. 40 CFR 152.50 - Contents of application.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... applicant must submit materials to demonstrate that he has complied with the FIFRA sec. 3(c)(1)(F) and... child-resistant packaging. If the product meets the criteria for child-resistant packaging, the... packaging. Refer to part 157 of this chapter for the criteria and certification requirements. (h) Request...

  5. 40 CFR 152.50 - Contents of application.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... applicant must submit materials to demonstrate that he has complied with the FIFRA sec. 3(c)(1)(F) and... child-resistant packaging. If the product meets the criteria for child-resistant packaging, the... packaging. Refer to part 157 of this chapter for the criteria and certification requirements. (h) Request...

  6. Recycling research progress at the Forest Products Laboratory.

    Treesearch

    1995-01-01

    This document summarizes accomplishments of USDA Forest Service researchers in the area of recycling. Specifically, it describes work in economic assessment, paper recycling, recycled housing and industrial applications of recycled materials, other recycling applications, and technology transfer. The literature list includes the references cited in the text and...

  7. Detecting Nanophase Weathering Products with CheMin: Reference Intensity Ratios of Allophane, Aluminosilicate Gel, and Ferrihydrite

    NASA Technical Reports Server (NTRS)

    Rampe, E. B.; Bish, D. L.; Chipera, S. J.; Morris, R. V.; Achilles, C. N.; Ming, D W.; Blake, D. F.; Anderson, R. C.; Bristow, T. F.; Crisp, A.; hide

    2013-01-01

    X-ray diffraction (XRD) data collected of the Rocknest samples by the CheMin instrument on Mars Science Laboratory suggest the presence of poorly crystalline or amorphous materials [1], such as nanophase weathering products or volcanic and impact glasses. The identification of the type(s) of X-ray amorphous material at Rocknest is important because it can elucidate past aqueous weathering processes. The presence of volcanic and impact glasses would indicate that little chemical weathering has occurred because glass is highly susceptible to aqueous alteration. The presence of nanophase weathering products, such as allophane, nanophase iron-oxides, and/or palagonite, would indicate incipient chemical weathering. Furthermore, the types of weathering products present could help constrain pH conditions and identify which primary phases altered to form the weathering products. Quantitative analysis of phases from CheMin data is achieved through Reference Intensity Ratios (RIRs) and Rietveld refinement. The RIR of a mineral (or mineraloid) that relates the scattering power of that mineral (typically the most intense diffraction line) to the scattering power of a separate mineral standard such as corundum [2]. RIRs can be calculated from XRD patterns measured in the laboratory by mixing a mineral with a standard in known abundances and comparing diffraction line intensities of the mineral to the standard. X-ray amorphous phases (e.g., nanophase weathering products) have broad scattering signatures rather than sharp diffraction lines. Thus, RIRs of X-ray amorphous materials are calculated by comparing the area under one of these broad scattering signals with the area under a diffraction line in the standard. Here, we measured XRD patterns of nanophase weathering products (allophane, aluminosilicate gel, and ferrihydrite) mixed with a mineral standard (beryl) in the CheMinIV laboratory instrument and calculated their RIRs to help constrain the abundances of these phases in the Rocknest samples.

  8. JPRS Report, Science & Technology, USSR: Materials Science

    DTIC Science & Technology

    1988-03-11

    crystallization of the amorphous phase, and subsequent growth of ß-boron grains. References 5: all Russian. 2415/9835 UDC 621.033.67 Erosion of Materials in...Weightlessness and Effect of Magnetic Field on Liquation Processes in InSb Crystals (V. S. Zemskov, M. R. Raukhman; FIZIKA I KHIMIYA OBRABOTKI MATERIALOV, No...No 7, Jul 87) 13 Production of CdP2^CdAs2 Solid-Solution Single Crystals and Measurement of Their Cathodoluminescence Spectra (V, B, Lazarev, S

  9. Development of references of anomalies detection on P91 material using Self-Magnetic Leakage Field (SMLF) technique

    NASA Astrophysics Data System (ADS)

    Husin, Shuib; Afiq Pauzi, Ahmad; Yunus, Salmi Mohd; Ghafar, Mohd Hafiz Abdul; Adilin Sekari, Saiful

    2017-10-01

    This technical paper demonstrates the successful of the application of self-magnetic leakage field (SMLF) technique in detecting anomalies in weldment of a thick P91 materials joint (1 inch thickness). Boiler components such as boiler tubes, stub boiler at penthouse and energy piping such as hot reheat pipe (HRP) and H-balance energy piping to turbine are made of P91 material. P91 is ferromagnetic material, therefore the technique of self-magnetic leakage field (SMLF) is applicable for P91 in detecting anomalies within material (internal defects). The technique is categorized under non-destructive technique (NDT). It is the second passive method after acoustic emission (AE), at which the information on structures radiation (magnetic field and energy waves) is used. The measured magnetic leakage field of a product or component is a magnetic leakage field occurring on the component’s surface in the zone of dislocation stable slipbands under the influence of operational (in-service) or residual stresses or in zones of maximum inhomogeneity of metal structure in new products or components. Inter-granular and trans-granular cracks, inclusion, void, cavity and corrosion are considered types of inhomogeneity and discontinuity in material where obviously the output of magnetic leakage field will be shown when using this technique. The technique does not required surface preparation for the component to be inspected. This technique is contact-type inspection, which means the sensor has to touch or in-contact to the component’s surface during inspection. The results of application of SMLF technique on the developed P91 reference blocks have demonstrated that the technique is practical to be used for anomaly inspection and detection as well as identification of anomalies’ location. The evaluation of this passive self-magnetic leakage field (SMLF) technique has been verified by other conventional non-destructive tests (NDTs) on the reference blocks where simulated defects/anomalies have been developed inside at the weldment. The results from the inspection test showed that the signatures of magnetic leakage field gradient distribution prove that the peak is found on the location of defect/anomaly in the reference block. It is in agreement with the evidence of anomaly that seen in the radiography test film (RT).

  10. Development and co-validation of porcine insulin certified reference material by high-performance liquid chromatography-isotope dilution mass spectrometry.

    PubMed

    Wu, Liqing; Takatsu, Akiko; Park, Sang-Ryoul; Yang, Bin; Yang, Huaxin; Kinumi, Tomoya; Wang, Jing; Bi, Jiaming; Wang, Yang

    2015-04-01

    This article concerns the development and co-validation of a porcine insulin (pINS) certified reference material (CRM) produced by the National Institute of Metrology, People's Republic of China. Each CRM unit contained about 15 mg of purified solid pINS. The moisture content, amount of ignition residue, molecular mass, and purity of the pINS were measured. Both high-performance liquid chromatography-isotope dilution mass spectrometry and a purity deduction method were used to determine the mass fraction of the pINS. Fifteen units were selected to study the between-bottle homogeneity, and no inhomogeneity was observed. A stability study concluded that the CRM was stable for at least 12 months at -20 °C. The certified value of the CRM was (0.892 ± 0.036) g/g. A co-validation of the CRM was performed among Chinese, Japanese, and Korean laboratories under the framework of the Asian Collaboration on Reference Materials. The co-validation results agreed well with the certified value of the CRM. Consequently, the pINS CRM may be used as a calibration material or as a validation standard for pharmaceutical purposes to improve the quality of pharmaceutical products.

  11. Research of Acoustic Properties of Materials with the Purpose of Their Use at Design of Special Noise Protective Clothes for Oil and Gas Industry

    NASA Astrophysics Data System (ADS)

    Drofa, E. A.; Lipilina, E. Yu

    2018-01-01

    The article is devoted to the substantiation of the choice of a rational package of materials, which has the greatest noise-protective properties when designing special clothes with reference to the oil and gas industry. Studies were conducted to assess the factors that have the most significant effect on the noise-protective properties of clothing. Conclusions are made about the possibility of using the developed technique for studying the noise-protective properties of materials in selecting rational packages of materials for the production of special clothes with high noise-protective properties.

  12. Quantitative 1H NMR: Development and Potential of an Analytical Method – an Update

    PubMed Central

    Pauli, Guido F.; Gödecke, Tanja; Jaki, Birgit U.; Lankin, David C.

    2012-01-01

    Covering the literature from mid-2004 until the end of 2011, this review continues a previous literature overview on quantitative 1H NMR (qHNMR) methodology and its applications in the analysis of natural products (NPs). Among the foremost advantages of qHNMR is its accurate function with external calibration, the lack of any requirement for identical reference materials, a high precision and accuracy when properly validated, and an ability to quantitate multiple analytes simultaneously. As a result of the inclusion of over 170 new references, this updated review summarizes a wealth of detailed experiential evidence and newly developed methodology that supports qHNMR as a valuable and unbiased analytical tool for natural product and other areas of research. PMID:22482996

  13. Analytical sensitivity of current best-in-class malaria rapid diagnostic tests.

    PubMed

    Jimenez, Alfons; Rees-Channer, Roxanne R; Perera, Rushini; Gamboa, Dionicia; Chiodini, Peter L; González, Iveth J; Mayor, Alfredo; Ding, Xavier C

    2017-03-24

    Rapid diagnostic tests (RDTs) are today the most widely used method for malaria diagnosis and are recommended, alongside microscopy, for the confirmation of suspected cases before the administration of anti-malarial treatment. The diagnostic performance of RDTs, as compared to microscopy or PCR is well described but the actual analytical sensitivity of current best-in-class tests is poorly documented. This value is however a key performance indicator and a benchmark value needed to developed new RDTs of improved sensitivity. Thirteen RDTs detecting either the Plasmodium falciparum histidine rich protein 2 (HRP2) or the plasmodial lactate dehydrogenase (pLDH) antigens were selected from the best performing RDTs according to the WHO-FIND product testing programme. The analytical sensitivity of these products was evaluated using a range of reference materials including P. falciparum and Plasmodium vivax whole parasite samples as well as recombinant proteins. The best performing HRP2-based RDTs could detect all P. falciparum cultured samples at concentrations as low as 0.8 ng/mL of HRP2. The limit of detection of the best performing pLDH-based RDT specifically detecting P. vivax was 25 ng/mL of pLDH. The analytical sensitivity of P. vivax and Pan pLDH-based RDTs appears to vary considerably from product to product, and improvement of the limit-of-detection for P. vivax detecting RDTs is needed to match the performance of HRP2 and Pf pLDH-based RDTs for P. falciparum. Different assays using different reference materials produce different values for antigen concentration in a given specimen, highlighting the need to establish universal reference assays.

  14. Silver Nanoparticles: Technological Advances, Societal Impacts, and Metrological Challenges

    PubMed Central

    Calderón-Jiménez, Bryan; Johnson, Monique E.; Montoro Bustos, Antonio R.; Murphy, Karen E.; Winchester, Michael R.; Vega Baudrit, José R.

    2017-01-01

    Silver nanoparticles (AgNPs) show different physical and chemical properties compared to their macroscale analogs. This is primarily due to their small size and, consequently, the exceptional surface area of these materials. Presently, advances in the synthesis, stabilization, and production of AgNPs have fostered a new generation of commercial products and intensified scientific investigation within the nanotechnology field. The use of AgNPs in commercial products is increasing and impacts on the environment and human health are largely unknown. This article discusses advances in AgNP production and presents an overview of the commercial, societal, and environmental impacts of this emerging nanoparticle (NP), and nanomaterials in general. Finally, we examine the challenges associated with AgNP characterization, discuss the importance of the development of NP reference materials (RMs) and explore their role as a metrological mechanism to improve the quality and comparability of NP measurements. PMID:28271059

  15. Silver nanoparticles: technological advances, societal impacts, and metrological challenges

    NASA Astrophysics Data System (ADS)

    Calderón-Jiménez, Bryan; Johnson, Monique E.; Montoro Bustos, Antonio R.; Murphy, Karen E.; Winchester, Michael R.; Vega Baudrit, José R.

    2017-02-01

    Silver nanoparticles (AgNPs) show different physical and chemical properties compared to their macroscale analogs. This is primarily due to their small size and, consequently, the exceptional surface area of these materials. Presently, advances in the synthesis, stabilization, and production of AgNPs have fostered a new generation of commercial products and intensified scientific investigation within the nanotechnology field. The use of AgNPs in commercial products is increasing and impacts on the environment and human health are largely unknown. This article discusses advances in AgNP production and presents an overview of the commercial, societal, and environmental impacts of this emerging nanoparticle (NP), and nanomaterials in general. Finally, we examine the challenges associated with AgNP characterization, discuss the importance of the development of NP reference materials (RMs) and explore their role as a metrological mechanism to improve the quality and comparability of NP measurements.

  16. Silver Nanoparticles: Technological Advances, Societal Impacts, and Metrological Challenges.

    PubMed

    Calderón-Jiménez, Bryan; Johnson, Monique E; Montoro Bustos, Antonio R; Murphy, Karen E; Winchester, Michael R; Vega Baudrit, José R

    2017-01-01

    Silver nanoparticles (AgNPs) show different physical and chemical properties compared to their macroscale analogs. This is primarily due to their small size and, consequently, the exceptional surface area of these materials. Presently, advances in the synthesis, stabilization, and production of AgNPs have fostered a new generation of commercial products and intensified scientific investigation within the nanotechnology field. The use of AgNPs in commercial products is increasing and impacts on the environment and human health are largely unknown. This article discusses advances in AgNP production and presents an overview of the commercial, societal, and environmental impacts of this emerging nanoparticle (NP), and nanomaterials in general. Finally, we examine the challenges associated with AgNP characterization, discuss the importance of the development of NP reference materials (RMs) and explore their role as a metrological mechanism to improve the quality and comparability of NP measurements.

  17. Microbial conversion of low-rank coal: characterization of biodegraded product

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilson, B.W.; Bean, R.M.; Franz, J.A.

    The authors have characterized products obtained from the action of the fungus Polyporus versicolor on oxidized North Dakota (ND) lignite. These analyses showed that, compared to feed coal, the bioconverted materials had higher hydrogen:carbon and oxygen:carbon ratios, but were proportionately lower in aliphatic hydrogen, as determined by infrared (IR) spectroscopy. The acid-precipitated extract was dissolved in dilute base and analyzed by /sup 13/C nuclear magnetic resonance (NMR) spectroscopy. Of the 60% of the carbon accounted for, approximately 51% of the carbon atoms were aromatic, 20% were assigned to carboxylic acid groups, and the remainder were aliphatic carbon. Proton NMR spectramore » of the acid-precipitated material revealed approximately equal proportions of aromatic and aliphatic hydrogen. The bioconverted materials were highly polar and exhibited a wide range in apparent molecular weight; most material was over 10,000 Da at acidic pH, as determined by ultrafiltration experiments. Freeze-dried product material was soluble in water but was essentially insoluble in other organic solvents. Calorimetric measurements on samples of the freeze-dried extract showed that, on a per-weight basis, it retained 94-97% of the heating value of the feed coal. 12 references, 5 figures, 2 tables.« less

  18. Progress in Ion Transport Membranes for Gas Separation Applications

    NASA Astrophysics Data System (ADS)

    Bose, Arun C.; Stiegel, Gary J.; Armstrong, Phillip A.; Halper, Barry J.; (Ted) Foster, E. P.

    This chapter describes the evolution and advances of ion transport membranes for gas separation applications, especially separation of oxygen from air. In partnership with the US Department of Energy (DOE), Air Products and Chemicals, Inc. (Air Products) successfully developed a novel class of mixed ion-electron conducting materials and membrane architecture. These novel materials are referred to as ion transport membranes (ITM). Generically, ITMs consist of modified perovskite and brownmillerite oxide solid electrolytes and provide high oxygen anion and electron conduction typically at high temperatures driven by an oxygen potential gradient without the need for external power. The partial pressure ratio across the ITM layer creates the driving force for oxygen separation.

  19. Reference-material system for estimating health and environmental risks of selected material cycles and energy systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Crowther, M.A.; Moskowitz, P.D.

    1981-07-01

    Sample analyses and detailed documentation are presented for a Reference Material System (RMS) to estimate health and environmental risks of different material cycles and energy systems. Data inputs described include: end-use material demands, efficiency coefficients, environmental emission coefficients, fuel demand coefficients, labor productivity estimates, and occupational health and safety coefficients. Application of this model permits analysts to estimate fuel use (e.g., Btu), occupational risk (e.g., fatalities), and environmental emissions (e.g., sulfur oxide) for specific material trajectories or complete energy systems. Model uncertainty is quantitatively defined by presenting a range of estimates for each data input. Systematic uncertainty not quantified relatesmore » to the boundaries chosen for analysis and reference system specification. Although the RMS can be used to analyze material system impacts for many different energy technologies, it was specifically used to examine the health and environmental risks of producing the following four types of photovoltaic devices: silicon n/p single-crystal cells produced by a Czochralski process; silicon metal/insulator/semiconductor (MIS) cells produced by a ribbon-growing process; cadmium sulfide/copper sulfide backwall cells produced by a spray deposition process; and gallium arsenide cells with 500X concentrator produced by a modified Czochralski process. Emission coefficients for particulates, sulfur dioxide and nitrogen dioxide; solid waste; total suspended solids in water; and, where applicable, air and solid waste residuals for arsenic, cadmium, gallium, and silicon are examined and presented. Where data are available the coefficients for particulates, sulfur oxides, and nitrogen oxides include both process and on-site fuel-burning emissions.« less

  20. An Investigation of Alternate Synthesis for 2,2’ -BIS(Phenylethynyl)-5, 5’ -Diaminobenzidine

    DTIC Science & Technology

    1985-05-01

    essentially complete reaction of starting material to give cleanly the biphenyl tetraacetamide compound VIla. After work-up, the product melting point ...of compound llh in ethanolic potassium hydroxide with and without diethanolamine catalysis iReference 34) gave a product with a high melting point ...After cooling, aqueous work-up gave a precipitate, which after drying, displayed a low melting point (110-130 0 C). The crude compound was purified by

  1. Extraterrestrial processing and manufacturing of large space systems, volume 1, chapters 1-6

    NASA Technical Reports Server (NTRS)

    Miller, R. H.; Smith, D. B. S.

    1979-01-01

    Space program scenarios for production of large space structures from lunar materials are defined. The concept of the space manufacturing facility (SMF) is presented. The manufacturing processes and equipment for the SMF are defined and the conceptual layouts are described for the production of solar cells and arrays, structures and joints, conduits, waveguides, RF equipment radiators, wire cables, and converters. A 'reference' SMF was designed and its operation requirements are described.

  2. Quality Control: (Material) Safety Data Sheets.

    PubMed

    Allen, Loyd V

    2017-01-01

    Safety Data Sheets (formerly Material Safety Data Sheets) are a system for cataloging information on chemicals, chemical compounds, and chemical mixtures and include instructions for the safe use and potential hazards associated with a particular material or product. At present, there are 16 sections of Safety Data Sheets, and these sections are discussed in this article. Two United States Pharmacopeia compounding-related chapters (<795> and <800>) refer to Safety Data Sheets, and this article provides a brief discussion on the terminology contained within those chapters. Copyright© by International Journal of Pharmaceutical Compounding, Inc.

  3. The availability of references and the sponsorship of original research cited in pharmaceutical advertisements

    PubMed Central

    Cooper, Richelle J.; Schriger, David L.

    2005-01-01

    Background The primary goal of pharmaceutical advertisements is to convince physicians to prescribe the manufacturer's product. We sought to determine what materials are cited in support of claims in pharmaceutical ads and medical research articles, and whether health care professionals seeking to verify the claims could obtain these references. Methods We reviewed 438 unique ads from the 1999 issues of 10 American medical journals, and a random sample of 400 references in medical research articles selected from the same journals. We classified references as journal article, data on file, meeting abstract or presentation, book or monograph, marketing report, prescribing information, government document or Internet site. We attempted to confirm or obtain each reference through library and Internet searches or by direct request from the manufacturer. The main outcome we sought to determine was the availability of the reference to a clinician. We also ascertained the source of funding for original research cited in the ads and the research articles. Results In the 438 ads with medical claims, 126 contained no references and 312 contained 721 unique references. Of these ad references, 55% (396/721) cited journal articles and 19% (135/721) cited data on file. In contrast, in the sample of research article references, 88% (351/400) cited journal articles and 8% (33/400) cited books. Overall, 84% of the citations from the ads were available: 98% of journal articles, 86% of books, 71% of meeting abstracts or presentations and 20% of data-on-file references. In all, 99% of the sample of research article references were available. We determined that 58% of the original research cited in the pharmaceutical ads was sponsored by or had an author affiliated with the product's manufacturer, as compared with 8% of the articles cited in the research articles. Interpretation Many pharmaceutical ads contain no references for medical claims. Although references to journal articles were usually obtainable, other published sources were not as easily acquired. The majority of unpublished data-on-file references were not available, and the majority of original research cited to substantiate claims in the pharmaceutical ads was funded by or had authors affiliated with the product's manufacturer. PMID:15710940

  4. The availability of references and the sponsorship of original research cited in pharmaceutical advertisements.

    PubMed

    Cooper, Richelle J; Schriger, David L

    2005-02-15

    The primary goal of pharmaceutical advertisements is to convince physicians to prescribe the manufacturer's product. We sought to determine what materials are cited in support of claims in pharmaceutical ads and medical research articles, and whether health care professionals seeking to verify the claims could obtain these references. We reviewed 438 unique ads from the 1999 issues of 10 American medical journals, and a random sample of 400 references in medical research articles selected from the same journals. We classified references as journal article, data on file, meeting abstract or presentation, book or monograph, marketing report, prescribing information, government document or Internet site. We attempted to confirm or obtain each reference through library and Internet searches or by direct request from the manufacturer. The main outcome we sought to determine was the availability of the reference to a clinician. We also ascertained the source of funding for original research cited in the ads and the research articles. In the 438 ads with medical claims, 126 contained no references and 312 contained 721 unique references. Of these ad references, 55% (396/721) cited journal articles and 19% (135/721) cited data on file. In contrast, in the sample of research article references, 88% (351/400) cited journal articles and 8% (33/400) cited books. Overall, 84% of the citations from the ads were available: 98% of journal articles, 86% of books, 71% of meeting abstracts or presentations and 20% of data-on-file references. In all, 99% of the sample of research article references were available. We determined that 58% of the original research cited in the pharmaceutical ads was sponsored by or had an author affiliated with the product's manufacturer, as compared with 8% of the articles cited in the research articles. Many pharmaceutical ads contain no references for medical claims. Although references to journal articles were usually obtainable, other published sources were not as easily acquired. The majority of unpublished data-on-file references were not available, and the majority of original research cited to substantiate claims in the pharmaceutical ads was funded by or had authors affiliated with the product's manufacturer.

  5. Health hazards associated with the use of di-(2-ethylhexyl) phthalate (commonly referred to as DOP) in HEPA filter test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1995-01-01

    Di-(2-ethylhexyl) phthalate (DEHP), commonly referred to as di-octyl phthalate, is an important production chemical in the US. In addition to its major use as an additive in plastics, DEHP is widely used to evaluate the effectiveness of high efficiency particulate air (HEPA) filters. Historically, DEHP was also used in quantitative fit testing for respirators. Evaluations of this compound a decade ago showed that it can induce hepatocellular carcinomas in laboratory animals. Although most Department of Energy (DOE) facilities have since discontinued using DEHP in respirator fit testing, DEHP continues to be used for evaluating HEPA filters. This report summarizes availablemore » information on the toxicity, mutagenicity, carcinogenicity, and other hazards and problems posed by DEHP, specifically with reference to HEPA filter testing. Information on work practice improvements as well as the availability and suitability of DEHP substitutes are also presented. This material should assist the DOE in the safe use of this material.« less

  6. Multivariate approaches for stability control of the olive oil reference materials for sensory analysis - part I: framework and fundamentals.

    PubMed

    Valverde-Som, Lucia; Ruiz-Samblás, Cristina; Rodríguez-García, Francisco P; Cuadros-Rodríguez, Luis

    2018-02-09

    Virgin olive oil is the only food product for which sensory analysis is regulated to classify it in different quality categories. To harmonize the results of the sensorial method, the use of standards or reference materials is crucial. The stability of sensory reference materials is required to enable their suitable control, aiming to confirm that their specific target values are maintained on an ongoing basis. Currently, such stability is monitored by means of sensory analysis and the sensory panels are in the paradoxical situation of controlling the standards that are devoted to controlling the panels. In the present study, several approaches based on similarity analysis are exploited. For each approach, the specific methodology to build a proper multivariate control chart to monitor the stability of the sensory properties is explained and discussed. The normalized Euclidean and Mahalanobis distances, the so-called nearness and hardiness indices respectively, have been defined as new similarity indices to range the values from 0 to 1. Also, the squared mean from Hotelling's T 2 -statistic and Q 2 -statistic has been proposed as another similarity index. © 2018 Society of Chemical Industry. © 2018 Society of Chemical Industry.

  7. 40 CFR 63.4551 - How do I demonstrate initial compliance with the emission limitations?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Surface Coating of Plastic Parts and Products Compliance Requirements for the Emission Rate Without Add-on..., Inks, and Related Products” (incorporated by reference, see § 63.14), information from the supplier or... enforcement agency that the formulation data are correct. If you purchase materials or monitor consumption by...

  8. 40 CFR 63.4551 - How do I demonstrate initial compliance with the emission limitations?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Surface Coating of Plastic Parts and Products Compliance Requirements for the Emission Rate Without Add-on..., Inks, and Related Products” (incorporated by reference, see § 63.14), information from the supplier or... enforcement agency that the formulation data are correct. If you purchase materials or monitor consumption by...

  9. 20 CFR 220.144 - Evaluation guides for a self-employed claimant.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... farm. (B) The claimant will have presented strong evidence that he or she is materially participating... land. (iii) Production. The term “production” refers to the physical work performed and the expenses... on matters, such as rotation of crops, the type of crops to be grown, the type of livestock to be...

  10. 26 CFR 1.1402(a)-4 - Rentals from real estate.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ..., refers to the physical work performed and the expenses incurred in producing a commodity. It includes such activities as the actual work of planting, cultivating, and harvesting crops, and the furnishing... or tenant is to engage to a material degree in the physical work related to the production of such...

  11. 40 CFR 52.742 - Incorporation by reference.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... from the American Society for Testing and Materials (ASTM), 1916 Race Street, Philadelphia, PA 19103. (1) ASTM D1475-85, Standard Test Method for Density of Paint, Varnish, Lacquer, and Related Products, for § 52.741(a)(4)(i)(B)(3)(i). (2) ASTM D2369-87, Standard Test Method for Volatile Content of...

  12. An Automatic Reference Aid for Improving EFL Learners' Formulaic Expressions in Productive Language Use

    ERIC Educational Resources Information Center

    Chen, Mei-Hua; Huang, Chung-Chi; Huang, Shih-Ting; Chang, Jason S.; Liou, Hsien-Chin

    2014-01-01

    Formulaic language is important to language acquisition; however, English language learners are often reported to have problems with formulaic expressions. Several lists of formulaic sequences have been proposed, mainly for developing teaching and testing materials. However, their limited numbers and insufficient usage information seem unable to…

  13. Digital Tools: Enhancing Painting Skills among Malaysian Secondary School Students

    ERIC Educational Resources Information Center

    Samah, Azimah A.; Putih, Abu Talib; Hussin, Zaharah

    2016-01-01

    Digital tools refer to software applications in the production of artworks particularly in painting. Digital art work is materialized by using computers, software and a combination of computer peripherals such as tablet support. With the aid of electronic equipment, digital artists manipulate pixels or coloring with light to compose the work and…

  14. Technology and Organisation of Inka Pottery Production in the Leche Valley. Part I: Study of Clays

    NASA Astrophysics Data System (ADS)

    Hayashida, F.; Häusler, W.; Wagner, U.

    2003-09-01

    We report on an interdisciplinary approach to the study of finds of unfired clay lumps and unfired broken vessels from two workshops in the Leche Valley, north coast of Peru. The material is used as a reference in the study of pottery making at both workshops.

  15. Moving Toward SCORM Compliant Content Production at Educational Software Company: Technical and Administrative Challenges

    ERIC Educational Resources Information Center

    Kultur, Can; Oytun, Erden; Cagiltay, Kursat; Ozden, M. Yasar; Kucuk, Mehmet Emin

    2004-01-01

    The Shareable Content Object Reference Model (SCORM) aims to standardize electronic course content, its packaging and delivery. Instructional designers and e-learning material producer organizations accept SCORM?s significant impact on instructional design/delivery process, however not much known about how such standards will be implemented to…

  16. Impact of Intellectual Property Laws on Part-Time Faculty. The Effective Voice for You.

    ERIC Educational Resources Information Center

    Duby, James R., Jr.

    This guide explains some of the intellectual property rights of part-time college faculty members and the circumstances under which faculty can defend intellectual property rights. The term "intellectual property" refers to proprietary information, materials, or products, the owner of which may possess intellectual property rights under trademark,…

  17. HEAVY METALS IN RECOVERED FINES FOR CONSTRUCTION AND DEMOLITION DEBRIS RECYCLING FACILITIES IN FLORIDA

    EPA Science Inventory

    A major product recovered from the processing and recycling of construction and demolition (C&D) debris is screened soil, also referred to as fines. A proposed reuse option for C&D debris fines is fill material, typically in construction projects as a substitute for natural soil....

  18. Teacher Effectiveness Research. Part II: Special Topics. Bibliographies in Education No. 78.

    ERIC Educational Resources Information Center

    Gilliss, Geraldine; Moll, Marita

    This 723-item bibliography lists materials on teacher effectiveness research published from 1978 to early 1984. Reference to some earlier works of significance is also included. Teacher effectiveness research is here defined to include principally studies conducted in the presage-context-process-product tradition in an attempt to determine…

  19. Reference materials for molecular diagnostics: Current achievements and future strategies.

    PubMed

    Jing, Rongrong; Wang, Huimin; Ju, Shaoqing; Cui, Ming

    2018-06-01

    Molecular diagnoses have become more widespread in many areas of laboratory medicine where qualitative or quantitative approaches are used to detect nucleic acids. The increasing number of assay methods and the targets for molecular diagnostics contribute to variability in the test results among clinical laboratories. Thus, reference materials (RMs) are required to enhance the comparability of results. This review focuses on the definition of RMs as well as the production and characteristics of higher order RMs from different organizations and their future strategies. We describe the recent progress in RMs, including the definition of RMs by the Joint Committee for Guides in Metrology, as well as the production and characteristics of higher order RMs by international official bodies. There is an urgent need for RMs in nucleic acid testing, especially higher order RMs. To advance the harmonization and standardization of clinical nucleic acid detection, cooperation between the above organizations is proposed and different approaches to higher order RMs development are also needed. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  20. High Power Laser Processing Of Materials

    NASA Astrophysics Data System (ADS)

    Martyr, D. R.; Holt, T.

    1987-09-01

    The first practical demonstration of a laser device was in 1960 and in the following years, the high power carbon dioxide laser has matured as an industrial machine tool. Modern carbon dioxide gas lasers can be used for cutting, welding, heat treatment, drilling, scribing and marking. Since their invention over 25 years ago they are now becoming recognised as highly reliable devices capable of achieving huge savings in production costs in many situations. This paper introduces the basic laser processing techniques of cutting, welding and heat treatment as they apply to the most common engineering materials. Typical processing speeds achieved with a wide range of laser powers are reported. Accuracies achievable and fit-up tolerances required are presented. Methods of integrating lasers with machine tools are described and their suitability in a wide range of manufacturing industries is described by reference to recent installations. Examples from small batch manufacturing, high volume production using dedicated laser welding equipment, and high volume manufacturing using 'flexible' automated laser welding equipment are described Future applications of laser processing are suggested by reference to current process developments.

  1. Naturally occurring radioactive materials (NORM): a matter of wide societal implication.

    PubMed

    Pescatore, C; Menon, S

    2000-12-01

    Naturally occurring radioactive materials are ubiquitous on Earth and their radioactivity may become concentrated as a result of human activities. Numerous industries produce concentrated radioactivity in their by-products: the coal industry, petroleum extraction and processing, water treatment, etc. The present reference system of radiation protection does not provide a complete framework for the coherent management of all types of radioactively contaminated materials. Inconsistencies in waste management policy and practice can be noted across the board, and especially vis-à-vis the management of radioactive waste from the nuclear industry. This article reviews the present societal approach to manage materials that are radioactive but are often not recognised as being such, and place the management of radioactive materials from the nuclear industry in perspective.

  2. Production cost analysis of Euphorbia lathyris. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendel, D.A.

    1979-08-01

    The purpose of this study is to estimate costs of production for Euphorbia lathyris (hereafter referred to as Euphorbia) in commercial-scale quantities. Selection of five US locations for analysis was based on assumed climatic and cultivation requirements. The five areas are: nonirrigated areas (Southeast Kansas and Central Oklahoma, Northeast Louisiana and Central Mississippi, Southern Illinois), and irrigated areas: (San Joaquin Valley and the Imperial Valley, California and Yuma, Arizona). Cost estimates are tailored to reflect each region's requirements and capabilities. Variable costs for inputs such as cultivation, planting, fertilization, pesticide application, and harvesting include material costs, equipment ownership, operating costs,more » and labor. Fixed costs include land, management, and transportation of the plant material to a conversion facility. Euphorbia crop production costs, on the average, range between $215 per acre in nonirrigated areas to $500 per acre in irrigated areas. Extraction costs for conversion of Euphorbia plant material to oil are estimated at $33.76 per barrel of oil, assuming a plant capacity of 3000 dry ST/D. Estimated Euphorbia crop production costs are competitive with those of corn. Alfalfa production costs per acre are less than those of Euphorbia in the Kansas/Oklahoma and Southern Illinois site, but greater in the irrigated regions. This disparity is accounted for largely by differences in productivity and irrigation requirements.« less

  3. Cryogenics and its application with reference to spice grinding: a review.

    PubMed

    Balasubramanian, S; Gupta, Manoj Kumar; Singh, K K

    2012-01-01

    Cryogenics is the study of very low temperature and its application on different materials including biological products. Cryogenics has numerous applications in space science, electronics, automobiles, the manufacturing industry, sports and musical instruments, biological science and agriculture, etc. Cryogenic freezing finds pivotal application in food, that is, spices and condiments. Although there is a wide range of cryogens to produce the desired low temperature, generally liquid nitrogen (LN₂) is used in food grinding. The application of low temperature shows a promising pathway to produce higher quality end product with higher flavor and volatile oil retention. Cryogenic grinders generally consist of precoolers and grinder with the cryogen distribution system. In such grinding systems, cryogens subject the raw material up to or lower than glass transition temperature before it is ground, thus eliminating much of the material and quality hassles of traditional grinding. At present, the capital investment including cryogen and handling costs escalate the final cost of the product. Thus, for large-scale production, a proper design to optimize and make it feasible is the need of the hour and understanding the behavior of different food materials at these low temperature conditions. This article reviews the scenario and application of cryogenics in different sectors, especially to spice grinding.

  4. Multimycotoxin UPLC-MS/MS for tea, herbal infusions and the derived drinkable products.

    PubMed

    Monbaliu, Sofie; Wu, Aibo; Zhang, Dabing; Van Peteghem, Carlos; De Saeger, Sarah

    2010-12-22

    In recent years the consumption of tea and herbal infusions has increased. These hot drinks are consumed as daily drinks as well as for medicinal purposes. All tea varieties (white, yellow, green, oolong, black and puerh) originate from the leaves of the tea plant, Camellia sinensis. All extracts made of plant or herbal materials which do not contain Camellia sinensis are referred as herbal infusions or tisanes. During processing and manufacturing fungal contamination of the plant materials is possible, enabling contamination of these products with mycotoxins. In this study a multimycotoxin UPLC-MS/MS method was developed and validated for the analysis of the raw tea and herbal infusion materials as well as for their drinkable products. The samples were analyzed by ultra-high-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS), with a mobile phase consisting of variable mixtures of water and methanol with 0.3% formic acid. The limits of detection for the different mycotoxins varied between 2.1 μg/kg and 121 μg/kg for raw materials and between 0.4 μg/L and 46 μg/L for drinkable products. Afterward 91 different tea and herbal infusion samples were analyzed. Only in one sample, Ceylon melange, 76 μg/kg fumonisin B(1) was detected. No mycotoxins were detected in the drinkable products.

  5. Reference Levels for Patient Radiation Doses in Interventional Radiology: Proposed Initial Values for U.S. Practice1

    PubMed Central

    Miller, Donald L.; Kwon, Deukwoo; Bonavia, Grant H.

    2009-01-01

    Purpose: To propose initial values for patient reference levels for fluoroscopically guided procedures in the United States. Materials and Methods: This secondary analysis of data from the Radiation Doses in Interventional Radiology Procedures (RAD-IR) study was conducted under a protocol approved by the institutional review board and was HIPAA compliant. Dose distributions (percentiles) were calculated for each type of procedure in the RAD-IR study where there were data from at least 30 cases. Confidence intervals for the dose distributions were determined by using bootstrap resampling. Weight banding and size correction methods for normalizing dose to patient body habitus were tested. Results: The different methods for normalizing patient radiation dose according to patient weight gave results that were not significantly different (P > .05). The 75th percentile patient radiation doses normalized with weight banding were not significantly different from those that were uncorrected for body habitus. Proposed initial reference levels for various interventional procedures are provided for reference air kerma, kerma-area product, fluoroscopy time, and number of images. Conclusion: Sufficient data exist to permit an initial proposal of values for reference levels for interventional radiologic procedures in the United States. For ease of use, reference levels without correction for body habitus are recommended. A national registry of radiation-dose data for interventional radiologic procedures is a necessary next step to refine these reference levels. © RSNA, 2009 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.2533090354/-/DC1 PMID:19789226

  6. Cytotoxicity and reactive oxygen species generation from aggregated carbon and carbonaceous nanoparticulate materials

    PubMed Central

    Garza, Kristine M; Soto, Karla F; Murr, Lawrence E

    2008-01-01

    We have investigated the cytotoxicity and reactive oxygen species (ROS) generation for indoor and outdoor soots: candle, wood, diesel, tire, and natural gas burner soots – along with surrogate black carbon, various multiwall carbon nanotube aggregate materials, TiO2 (anatase) and chrysotile asbestos as reference materials. All soots were observed utilizing TEM and FESEM to be composed of aggregated, primary spherules (20–80 nm diameter) forming complex, branched fractal structures. These spherules were composed of intercalated, turbostratic arrangements of curved graphene fragments with varying concentrations of polycyclic aromatic hydrocarbon (PAH) isomers. In vitro cultures with an immortalized human lung epithelial carcinoma cell line (A549) treated with these materials showed decreased cell viability and variations in ROS production, with no correlations to PAH content. The data demonstrate that soots are cytotoxic and that cytotoxicity is not related to PAH content but is related to ROS generation, suggesting that soot induces cellular oxidative stress and that cell viability assays can be indicators of ROS production. PMID:18488419

  7. Anaerobic Digestion.

    PubMed

    Liebetrau, Jan; Sträuber, Heike; Kretzschmar, Jörg; Denysenko, Velina; Nelles, Michael

    2017-04-09

    The term anaerobic digestion usually refers to the microbial conversion of organic material to biogas, which mainly consists of methane and carbon dioxide. The technical application of the naturally-occurring process is used to provide a renewable energy carrier and - as the substrate is often waste material - to reduce the organic matter content of the substrate prior to disposal.Applications can be found in sewage sludge treatment, the treatment of industrial and municipal solid wastes and wastewaters (including landfill gas utilization), and the conversion of agricultural residues and energy crops.For biorefinery concepts, the anaerobic digestion (AD) process is, on the one hand, an option to treat organic residues from other production processes. Concomitant effects are the reduction of organic carbon within the treated substance, the conversion of nitrogen and sulfur components, and the production of an energy-rich gas - the biogas. On the other hand, the multistep conversion of complex organic material offers the possibility of interrupting the conversion chain and locking out intermediates for utilization as basic material within the chemical industry.

  8. Nuclear reference materials to meet the changing needs of the global nuclear community

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martin, H.R.; Gradle, C.G.; Narayanan, U.I.

    New Brunswick Laboratory (NBL) serves as the U.S. Government`s certifying authority for nuclear reference materials and measurement calibration standards. In this role, NBL provides nuclear reference materials certified for chemical and/or isotopic compositions traceable to a nationally accepted, internationally compatible reference base. Emphasis is now changing as to the types of traceable nuclear reference materials needed as operations change within the Department of Energy complex and at nuclear facilities around the world. New challenges include: environmental and waste minimization issues, facilities and materials transitioning from processing to storage modes with corresponding changes in the types of measurements being performed, emphasismore » on requirements for characterization of waste materials, and difficulties in transporting nuclear materials and international factors, including IAEA influences. During these changing times, it is critical that traceable reference materials be provided for calibration or validation of the performance of measurement systems. This paper will describe actions taken and planned to meet the changing reference material needs of the global nuclear community.« less

  9. From "farm to fork" strawberry system: current realities and potential innovative scenarios from life cycle assessment of non-renewable energy use and green house gas emissions.

    PubMed

    Girgenti, Vincenzo; Peano, Cristiana; Baudino, Claudio; Tecco, Nadia

    2014-03-01

    In this study, we analysed the environmental profile of the strawberry industry in Northern Italy. The analysis was conducted using two scenarios as reference systems: strawberry crops grown in unheated plastic tunnels using currently existing cultivation techniques, post-harvest management practices and consumption patterns (scenario 1) and the same strawberry cultivation chain in which some of the materials used were replaced with bio-based materials (scenario 2). In numerous studies, biodegradable polymers have been shown to be environmentally friendly, thus potentially reducing environmental impacts. These materials can be recycled into carbon dioxide and water through composting. Many materials, such as Mater-BI® and PLA®, are also derived from renewable resources. The methodology chosen for the environmental analysis was a life cycle assessment (LCA) based on a consequential approach developed to assess a product's overall environmental impact from the production system to its usage and disposal. In the field stage, a traditional mulching film (non-biodegradable) could be replaced with a biodegradable product. This change would result in waste production of 0 kg/ha for the bio-based product compared to 260 kg/ha of waste for polyethylene (PE). In the post-harvest stage, the issue addressed was the use and disposal of packaging materials. The innovative scenario evaluated herein pertains to the use of new packaging materials that increase the shelf life of strawberries, thereby decreasing product losses while increasing waste management efficiency at the level of a distribution platform and/or sales outlet. In the event of product deterioration or non-sale of the product, the packaging and its contents could be collected together as organic waste without any additional processes because the packaging is compostable according to EN13432. Scenario 2 would achieve reductions of 20% in the global warming potential and non-renewable energy impact categories. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Advanced Dairy Unit for Advanced Livestock Production Curriculum. Instructor's Guide. AGDEX 410/00.

    ERIC Educational Resources Information Center

    Coday, Stan; Stewart, Bob R.

    This instructor's guide contains 18 lessons for teaching advanced dairying in accordance with the Missouri State Board of Education's Vocational Instructional Management System. To make the unit easier for teachers to use, the following materials are provided in the front of the unit: objectives and competencies for each lesson, a references and…

  11. Streamlining the Acquisition Process: A DCAA Field-Grade Perspective

    DTIC Science & Technology

    2014-03-01

    Initial Capabilities Document IFRS International Financial Reporting Standards IPT Integrated Product Team IRR Independent Reference Review...the responsibilities, programmed focus, strategic plan and recent events impacting the organization. B. DEFENSE CONTRACT AUDIT AGENCY 1. DCAA...material misstatements, whether caused by error or fraud. The type of audit requested by the contracting officer will directly impact both the

  12. Software conversion history of the Flight Dynamics System (FDS)

    NASA Technical Reports Server (NTRS)

    Liu, K.

    1984-01-01

    This report summarizes the overall history of the Flight Dynamics System (FDS) applications software conversion project. It describes the background and nature of the project; traces the actual course of conversion; assesses the process, product, and personnel involved; and offers suggestions for future projects. It also contains lists of pertinent reference material and examples of supporting data.

  13. Greenhouse Operation and Management. Instructor Guide and Student Reference. Missouri Agricultural Education. Volume 21, Number 3.

    ERIC Educational Resources Information Center

    Wells, Judith A.; And Others

    These student and instructor materials for a one-semester course intended for high school juniors and seniors teach the following 24 lessons: (1) the scope and development of greenhouse production; (2) the economic importance of greenhouse crops; (3) careers in greenhouse operation and management; (4) greenhouse parts, structures, and coverings;…

  14. 40 CFR 1068.95 - What materials does this part reference?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... material from the Society of Automotive Engineers that we have incorporated by reference. The first column... reference it. Anyone may purchase copies of these materials from the Society of Automotive Engineers, 400... Materials Document number and name Part 1068reference SAE J1930, Electrical/Electronic Systems Diagnostic...

  15. 40 CFR 1068.95 - What materials does this part reference?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... material from the Society of Automotive Engineers that we have incorporated by reference. The first column... reference it. Anyone may purchase copies of these materials from the Society of Automotive Engineers, 400... Materials Document number and name Part 1068reference SAE J1930, Electrical/Electronic Systems Diagnostic...

  16. 40 CFR 1042.910 - Reference materials.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Reference materials. 1042.910 Section... Other Reference Information § 1042.910 Reference materials. Documents listed in this section have been... information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov...

  17. 40 CFR 1042.910 - Reference materials.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 33 2014-07-01 2014-07-01 false Reference materials. 1042.910 Section... Other Reference Information § 1042.910 Reference materials. Documents listed in this section have been... information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov...

  18. 40 CFR 1043.100 - Reference materials.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 33 2014-07-01 2014-07-01 false Reference materials. 1043.100 Section... § 1043.100 Reference materials. Documents listed in this section have been incorporated by reference into... the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov...

  19. Color prediction in textile application

    NASA Astrophysics Data System (ADS)

    De Lucia, Maurizio; Buonopane, Massimo

    2004-09-01

    Nowadays production systems of fancy yarns for knits allow the creation of extremely complex products in which many effects are obtained by means of color alteration. Current production technique consists in defining type and quantity of fibers by making preliminary samples. This samples are then compared with a reference one. This comparison is based on operator experience. Many samples are required in order to achieve a sample similar to the reference one. This work requires time and then additional costs for a textile manufacturer. In addition, the methodology is subjective. Nowadays, spectrophotometers are the only devices that seem to be able to provide objective indications. They are based on a spectral analysis of the light reflected by the knit material. In this paper the study of a new method for color evaluation of a mix of wool fibers with different colors is presented. First of all fiber characterization were carried out through scattering and absorption coefficients using the Kubelka-Munk theory. Then the estimated color was compared with a reference item, in order to define conformity by means of objective parameters. Finally, theoretical characterization was compared with the measured quantity. This allowed estimation of prediction quality.

  20. Research of footwear lining materials thermoconductive properties

    NASA Astrophysics Data System (ADS)

    Maksudova, U.; Ilkhamova, M.; Mirzayev, N.; Pazilova, D.

    2017-11-01

    Protective properties of footwear are influenced by a number of factors and the most important of them are: design features of the top and the bottom of the footwear, it’s shape, physical and mechanical properties of the components of which they are made. In course of work there were researched thermoconductive properties of different lining membrane materials used for production of high temperature protective footwear. Research results allow to select the appropriate materials by reference to thermoconductive properties during design of protective footwear for extreme conditions to prolong the wearer’s time of comfortable stay in conditions of exposure of elevated temperatures to a stack.

  1. Nuclear reference materials to meet the changing needs of the global nuclear community

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martin, H.R.; Gradle, C.G.; Narayanan, U.I.

    New Brunswick Laboratory (NBL) serves as the US Government`s Certifying Authority for nuclear reference materials and measurement calibration standards. In this role, NBL provides nuclear reference materials certified for chemical and/or isotopic compositions traceable to a nationally accepted, internationally compatible reference base. Emphasis is now changing as to the types of traceable nuclear reference materials needed as operations change within the Department of Energy (DOE) complex and at nuclear facilities around the world. Environmental and waste minimization issues, facilities and materials transitioning from processing to storage modes with corresponding changes in the types of measurements being performed, emphasis on requirementsmore » for characterization of waste materials, difficulties in transporting nuclear materials, and International factors, including International Atomic Energy Agency (IAEA) inspection of excess US nuclear materials, are all contributing influences. During these changing times, ft is critical that traceable reference materials be provided for calibration or validation of the performance of measurement systems. This paper will describe actions taken and planned to meet the changing reference material needs of the global nuclear community.« less

  2. Internet resources for dentistry: computer, Internet, reference, and sites for enhancing personal productivity of the dental professional.

    PubMed

    Guest, G F

    2000-08-15

    At the onset of the new millennium the Internet has become the new standard means of distributing information. In the last two to three years there has been an explosion of e-commerce with hundreds of new web sites being created every minute. For most corporate entities, a web site is as essential as the phone book listing used to be. Twenty years ago technologist directed how computer-based systems were utilized. Now it is the end users of personal computers that have gained expertise and drive the functionality of software applications. The computer, initially invented for mathematical functions, has transitioned from this role to an integrated communications device that provides the portal to the digital world. The Web needs to be used by healthcare professionals, not only for professional activities, but also for instant access to information and services "just when they need it." This will facilitate the longitudinal use of information as society continues to gain better information access skills. With the demand for current "just in time" information and the standards established by Internet protocols, reference sources of information may be maintained in dynamic fashion. News services have been available through the Internet for several years, but now reference materials such as online journals and digital textbooks have become available and have the potential to change the traditional publishing industry. The pace of change should make us consider Will Rogers' advice, "It isn't good enough to be moving in the right direction. If you are not moving fast enough, you can still get run over!" The intent of this article is to complement previous articles on Internet Resources published in this journal, by presenting information about web sites that present information on computer and Internet technologies, reference materials, news information, and information that lets us improve personal productivity. Neither the author, nor the Journal endorses any of the sites or products listed, but include these references and links as a matter of convenience for its readers.

  3. Reference Materials and Subject Matter Knowledge Codes for Airman Knowledge Testing

    DOT National Transportation Integrated Search

    2004-06-08

    The listings of reference materials and subject matter knowledge codes have been : prepared by the Federal Aviation Administration (FAA) to establish specific : references for all knowledge standards. The listings contain reference materials : to be ...

  4. Requirements and Techniques for Developing and Measuring Simulant Materials

    NASA Technical Reports Server (NTRS)

    Rickman, Doug; Owens, Charles; Howard, Rick

    2006-01-01

    The 1989 workshop report entitled Workshop on Production and Uses of Simulated Lunar Materials and the Lunar Regolith Simulant Materials: Recommendations for Standardization, Production, and Usage, NASA Technical Publication identify and reinforced a need for a set of standards and requirements for the production and usage of the lunar simulant materials. As NASA need prepares to return to the moon, a set of requirements have been developed for simulant materials and methods to produce and measure those simulants have been defined. Addressed in the requirements document are: 1) a method for evaluating the quality of any simulant of a regolith, 2) the minimum Characteristics for simulants of lunar regolith, and 3) a method to produce lunar regolith simulants needed for NASA's exploration mission. A method to evaluate new and current simulants has also been rigorously defined through the mathematics of Figures of Merit (FoM), a concept new to simulant development. A single FoM is conceptually an algorithm defining a single characteristic of a simulant and provides a clear comparison of that characteristic for both the simulant and a reference material. Included as an intrinsic part of the algorithm is a minimum acceptable performance for the characteristic of interest. The algorithms for the FoM for Standard Lunar Regolith Simulants are also explicitly keyed to a recommended method to make lunar simulants.

  5. The effect of various pozzolanic additives on the concrete strength index

    NASA Astrophysics Data System (ADS)

    Vitola, L.; Sahmenko, G.; Erdmane, D.; Bumanis, G.; Bajare, D.

    2017-10-01

    The concrete industry is searching continuously for new effective mineral additives to improve the concrete properties. Replacing cement with the pozzolanic additives in most cases has resulted not only in positive impact on the environment but also has improved strength and durability of the concrete. Effective pozzolanic additives can be obtained from natural resources such as volcanic ashes, kaolin and other sediments as well as from different production industries that create various by-products with high pozzolanic reactivity. Current research deals with effectiveness evaluation of various mineral additives/wastes, such as coal combustion bottom ash, barley bottom ash, waste glass and metakaolin containing waste as well as calcined illite clays as supplementary cementitious materials, to be used in concrete production as partial cement replacement. Most of the examined materials are used as waste stream materials with potential reactive effect on the concrete. Milling time and fineness of the tested supplementary material has been evaluated and effectiveness was detected. Results indicate that fineness of the tested materials has crucial effect on the concrete compressive strength index. Not in all cases the prolonged milling time can increase fineness and reactivity of the supplementary materials; however the optimal milling time and fineness of the pozolanic additives increased the strength index of concrete up to 1.16 comparing to reference, even in cases when cement was substituted by 20 w%.

  6. Analysis of waste coal from the enterprises of Kemerovo region as raw materials for production of ceramic materials

    NASA Astrophysics Data System (ADS)

    Stolboushkin, A. Yu; Akst, D. V.; Fomina, O. A.; Ivanov, A. I.; Syromyasov, V. A.

    2017-09-01

    The analysis of waste coal from mining enterprises of Kemerovo region as raw materials for production of building ceramics is given. The results of studies of material, chemical and mineralogical compositions of waste coal from Abashevskaya processing plant (Novokuznetsk) are presented. It was established that the chemical composition of waste coal refers to aluminosilicate raw materials with a high content of alumina and coloring oxides, the residual carbon content in the wastes is 12-25 %. According to the granulometric composition the waste coal is basically a sandy-dusty fraction with a small amount of clay particles (1-3 %). Additional grinding of coal waste and the introduction of a clay additive in an amount of up to 30 % are recommended. The results of the study of the mineral composition of waste coal are presented. Clay minerals are represented in the descending order by hydromuscovite, montmorillonite and kaolinite, minerals-impurities consist of quartz, feldspar fine-dispersed carbonates. The results of the investigation of ceramic-technological properties of waste coal, which belong to the group of moderately plastic low-melting raw materials, are given. As a result of a comprehensive study it was been established that with chemical, granulometric and mineralogical compositions waste coal with the reduced residual carbon can be used in the production of ceramic bricks.

  7. Reference-based optical characterization of glass-ceramic converter for high-power white LEDs

    NASA Astrophysics Data System (ADS)

    Engel, A.; Letz, M.; Zachau, T.; Pawlowski, E.; Seneschal-Merz, K.; Korb, T.; Enseling, D.; Hoppe, B.; Peuchert, U.; Hayden, J. S.

    2007-02-01

    Fluorescence techniques are known for their high sensitivity and are widely used as analytical tools and detection methods for product and process control, material sciences, environmental and bio-technical analysis, molecular genetics, cell biology, medical diagnostics and drug screening. According to DIN/ISO 17025 certified standards are used for fluorescence diagnostics having the drawback of giving relative values for fluorescence intensities only. Therefore reference materials for a quantitative characterization have to be related directly to the materials under investigation. In order to evaluate these figures it is necessary to calculate absolute numbers like absorption/excitation cross section and quantum yield. This can be done for different types of dopants in different materials like glass, glass ceramics, crystals or nano crystalline material embedded in polymer matrices. Here we consider a special type of glass ceramic with Ce doped YAG as the main crystalline phase. This material has been developed for the generation of white light realized by a blue 460 nm semiconductor transition using a yellow phosphor or converter material respectively. Our glass ceramic is a pure solid state solution for a yellow phosphor. For the production of such a kind of material a well controlled thermal treatment is employed to transfer the original glass into a glass ceramic with a specific crystalline phase. In our material Ce doped YAG crystallites of a size of several µm are embedded in a matrix of a residual glass. We present chemical, structural and spectroscopic properties of our material. Based on this we will discuss design options for white LED's with respect to heat management, scattering regime, reflection losses, chemical durability and stability against blue and UV radiation, which evolve from our recently developed material. In this paper we present first results on our approaches to evaluate quantum yield and light output. Used diagnostics are fluorescence (steady state, decay time) and absorption (remission, absorption) spectroscopy working in different temperature regimes (10 - 350 K) of the measured samples in order to get a microscopic view of the relevant physical processes and to prove the correctness of the obtained data.

  8. Positive control for cytotoxicity evaluation of dental vinyl polysiloxane impression materials using sodium lauryl sulfate.

    PubMed

    Kwon, Jae-Sung; Lee, Sang-Bae; Kim, Kwang-Mahn; Kim, Kyoung-Nam

    2014-11-01

    Vinyl polysiloxane (VPS) is elastomeric dental impression material which, despite having very few reports of adverse reactions, has shown high levels of cytotoxicity that is difficult to be interpreted without referencing to the positive control material. Therefore, in this study, positive control VPS was developed using sodium lauryl sulfate (SLS) for the reference of cytotoxicity test. The positive control VPS with SLS was formed with a different proportion of SLS (0, 1, 2, 4, 8 and 16 wt%) added to the base. The cytotoxicity test was then carried out using the extractions or dilutions of the extractions from each of the test samples using murine fibroblast cells (L929). The final product of positive control VPS behaved similar to commercially available VPS; being initially liquid-like and then becoming rubber-like. Ion chromatography showed that the level of SLS released from the product increased as the proportion of added SLS increased, consequently resulting in an increased level of cytotoxicity. Also, the commercially available VPS was less cytotoxic than the positive control VPS with more or equal to 2 wt% of SLS. However, even the VPS with the highest SLS (16 wt%) did not cause oral mucosa irritation during the animal study. The positive control VPS was successfully produced using SLS, which will be useful in terms of providing references during in vitro cytotoxicity testing.

  9. Efficacy and effectiveness of alcohol in the disinfection of semi-critical materials: a systematic review

    PubMed Central

    Ribeiro, Maíra Marques; Neumann, Verena Ashley; Padoveze, Maria Clara; Graziano, Kazuko Uchikawa

    2015-01-01

    Abstract Objective: to assess the efficacy and the effectiveness of 60-80% alcohol (v/v) in the disinfection of semi-critical materials which were either previously cleaned or not. Method: studies obtained from BIREME, IBECS, MEDLINE, ScIELO, PubMed, Ask Medline web portals, and references from other studies. Criteria were created to assess the methodological quality of articles. Out of the 906 studies found, 14 have been included. Results: after materials were disinfected with alcohol, microorganisms were detected in 104/282 (36.9%) effectiveness tests and in 23/92 (25.0%) efficacy tests that were conducted. In the field studies, disinfection was not achieved for 74/218 (33.9%) of the products that were submitted to previous cleaning and for 30/64 (46.9%) of the ones which were not submitted to previous cleaning. In the experimental studies, alcohol disinfection was not efficacy in 11/30 (36.7%) and 12/62 (19.4%) of products, respectively. The studies were not found to have followed standardized methods. Conclusion: disinfection of semi-critical products with alcohol 70% - or in an approximate concentration - cannot be recommended to all health care products in an unrestricted way. However, according to the type of semi-critical product, disinfection can be attained with or without previous cleaning. PMID:26444178

  10. Efficacy and effectiveness of alcohol in the disinfection of semi-critical materials: a systematic review.

    PubMed

    Ribeiro, Maíra Marques; Neumann, Verena Ashley; Padoveze, Maria Clara; Graziano, Kazuko Uchikawa

    2015-01-01

    to assess the efficacy and the effectiveness of 60-80% alcohol (v/v) in the disinfection of semi-critical materials which were either previously cleaned or not. studies obtained from BIREME, IBECS, MEDLINE, ScIELO, PubMed, Ask Medline web portals, and references from other studies. Criteria were created to assess the methodological quality of articles. Out of the 906 studies found, 14 have been included. after materials were disinfected with alcohol, microorganisms were detected in 104/282 (36.9%) effectiveness tests and in 23/92 (25.0%) efficacy tests that were conducted. In the field studies, disinfection was not achieved for 74/218 (33.9%) of the products that were submitted to previous cleaning and for 30/64 (46.9%) of the ones which were not submitted to previous cleaning. In the experimental studies, alcohol disinfection was not efficacy in 11/30 (36.7%) and 12/62 (19.4%) of products, respectively. The studies were not found to have followed standardized methods. disinfection of semi-critical products with alcohol 70% - or in an approximate concentration - cannot be recommended to all health care products in an unrestricted way. However, according to the type of semi-critical product, disinfection can be attained with or without previous cleaning.

  11. Development and validation of a method for mercury determination in seawater for the process control of a candidate certified reference material.

    PubMed

    Sánchez, Raquel; Snell, James; Held, Andrea; Emons, Hendrik

    2015-08-01

    A simple, robust and reliable method for mercury determination in seawater matrices based on the combination of cold vapour generation and inductively coupled plasma mass spectrometry (CV-ICP-MS) and its complete in-house validation are described. The method validation covers parameters such as linearity, limit of detection (LOD), limit of quantification (LOQ), trueness, repeatability, intermediate precision and robustness. A calibration curve covering the whole working range was achieved with coefficients of determination typically higher than 0.9992. The repeatability of the method (RSDrep) was 0.5 %, and the intermediate precision was 2.3 % at the target mass fraction of 20 ng/kg. Moreover, the method was robust with respect to the salinity of the seawater. The limit of quantification was 2.7 ng/kg, which corresponds to 13.5 % of the target mass fraction in the future certified reference material (20 ng/kg). An uncertainty budget for the measurement of mercury in seawater has been established. The relative expanded (k = 2) combined uncertainty is 6 %. The performance of the validated method was demonstrated by generating results for process control and a homogeneity study for the production of a candidate certified reference material.

  12. The role of appeals to tradition in origin food marketing. A survey among Polish consumers.

    PubMed

    Bryła, Paweł

    2015-08-01

    The frequency of the use of tradition in marketing is growing. Appealing to tradition reflects the need to have reference points, trust and stability. The perceived authenticity of a product is strongly connected with its origin, which is expressed by the factors of time (history), place (area), socialisation (local community) and naturalness (raw materials). The paper aims to examine consumer attitudes, preferences and behaviours regarding origin food in Poland. We carried out a survey in a representative sample of 1000 Polish consumers. According to our respondents, the characteristics differentiating origin food from conventional food include links with tradition as well as sensory and health properties. Referring to the typology proposed by van der Meulen, traditionality and territoriality are the most important characteristics of origin food. The perceived authenticity of origin products depends to the largest extent on such factors as: natural taste, product quality, sale in the region of origin and labelling. The most important determinants of origin food selection include: traditional recipe, taste, and product uniqueness. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Lean production of taste improved lipidic sodium benzoate formulations.

    PubMed

    Eckert, C; Pein, M; Breitkreutz, J

    2014-10-01

    Sodium benzoate is a highly soluble orphan drug with unpleasant taste and high daily dose. The aim of this study was to develop a child appropriate, individually dosable, and taste masked dosage form utilizing lipids in melt granulation process and tableting. A saliva resistant coated lipid granule produced by extrusion served as reference product. Low melting hard fat was found to be appropriate as lipid binder in high-shear granulation. The resulting granules were compressed to minitablets without addition of other excipients. Compression to 2mm minitablets decreased the dissolved API amount within the first 2 min of dissolution from 33% to 23%. The Euclidean distances, calculated from electronic tongue measurements, were reduced, indicating an improved taste. The reference product showed a lag time in dissolution, which is desirable for taste masking. Although a lag time was not achieved for the lipidic minitablets, drug release in various food materials was reduced to 2%, assuming a suitable taste masking for oral sodium benzoate administration. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Leaching behaviour and mechanical properties of copper flotation waste in stabilized/solidified products.

    PubMed

    Mesci, Başak; Coruh, Semra; Ergun, Osman Nuri

    2009-02-01

    This research describes the investigation of a cement-based solidification/stabilization process for the safe disposal of copper flotation waste and the effect on cement properties of the addition of copper flotation waste (CW) and clinoptilolite (C). In addition to the reference mixture, 17 different mixtures were prepared using different proportions of CW and C. Physical properties such as setting time, specific surface area and compressive strength were determined and compared to a reference mixture and Turkish standards (TS). Different mixtures with the copper flotation waste portion ranging from 2.5 to 12.5% by weight of the mixture were tested for copper leachability. The results show that as cement replacement materials especially clinoptilolite had clear effects on the mechanical properties. Substitution of 5% copper flotation waste for Portland cement gave a similar strength performance to the reference mixture. Higher copper flotation waste addition such as 12.5% replacement yielded lower strength values. As a result, copper flotation waste and clinoptilolite can be used as cementitious materials, and copper flotation waste also can be safely stabilized/solidified in a cement-based solidification/stabilization system.

  15. 76 FR 23288 - Certain Lined Paper Products From the People's Republic of China: Notice of Final Results of the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-26

    ... implements, reference materials such as mathematical tables, or printed items such as sticker sheets or.... Application of Adverse Facts Available Section 776(a) of the Act provides that, the Department shall apply... verified, we find that application of facts available is appropriate under sections 776(a)(2)(A), (B), and...

  16. Side Streams of Plant Food Processing As a Source of Valuable Compounds: Selected Examples.

    PubMed

    Schieber, Andreas

    2017-02-28

    Industrial processing of plant-derived raw materials generates enormous amounts of by-products. On one hand, these by-products constitute a serious disposal issue because they often emerge seasonally and are prone to microbial decay. On the other hand, they are an abundant source of valuable compounds, in particular secondary plant metabolites and cell wall materials, which may be recovered and used to functionalize foods and replace synthetic additives with ingredients of natural origin. This review covers 150 references and presents select studies performed between 2001 and 2016 on the recovery, characterization, and application of valuable constituents from grape pomace, apple pomace, potato peels, tomato pomace, carrot pomace, onion peels, by-products of citrus, mango, banana, and pineapple processing, side streams of olive oil production, and cereal by-products. The criteria used were economic importance, amounts generated, relevance of side streams as a source of valuable compounds, and reviews already published. Despite a plethora of studies carried out on the utilization of side streams, relatively few processes have yet found industrial application.

  17. Detection of the arylpropionamide-derived selective androgen receptor modulator (SARM) S-4 (Andarine) in a black-market product.

    PubMed

    Thevis, Mario; Geyer, Hans; Kamber, Matthias; Schänzer, Wilhelm

    2009-08-01

    Non-steroidal and tissue-selective anabolic agents such as selective androgen receptor modulators (SARMs) represent a promising class of therapeutics for the treatment of various diseases such as sarcopenia or cancer cachexia. Advanced compounds of SARMs are based on an arylpropionamide-derived structure and leading drug candidates have successfully completed phase-II-clinical trials. Although none of these therapeutics have been approved, their performance-enhancing qualities and the black-market availability of these products makes them a viable target for misuse in the athletic community. In 2008, SARMs were added to the Prohibited List established by the World Anti-Doping Agency (WADA). That SARMs are the subject of misuse even without clinical approval was proved for the first time by the detection of the drug candidate Andarine (also referred to as S-4, S-3-(4-acetylamino-phenoxy)-2-hydroxy-2-methyl-N-(4-nitro-3-trifluoromethyl-phenyl)-propionamide), advertised, sold and supplied via the Internet. The oily liquids, declared as green tea extracts and face moisturizer, were assayed using state-of-the-art analytical procedures and S-4 was found at concentrations of approximately 150 mg/mL. The authenticity of the product was demonstrated in comparison to reference material by liquid chromatography, high resolution/high accuracy (tandem) mass spectrometry using positive and negative electrospray ionization, and comparison to reference material. Moreover, an impurity resulting from poor product purification was detected, accounting for approximately 10% of S-4. This consisted of 2-hydroxy-2-methyl-N-(4-nitro-3-trifluoromethyl-phenyl)-3-(4-nitro-3-trifluoromethyl-phenylamino)-propionamide. The ease of purchasing non-approved drug candidates that could potentially increase athletic performance demonstrates the need to operate proactively in the continued fight against doping. The early inclusion of emerging drugs into routine sports drug testing procedures is a key element of preventive doping research, limiting the options for cheating athletes who aim to undermine the doping control system. Copyright 2009 John Wiley & Sons, Ltd.

  18. Discussion on the application of high additional value of high purity and high quality direct reduced iron

    NASA Astrophysics Data System (ADS)

    Yue, Chongfeng; Bai, Lu; Hong, Yicheng; Xu, Lijun

    2018-03-01

    The high purity and high quality direct reduced iron(DRI) products which were produced by high grade and high quality iron powder, with a high grade and low impurity characteristics. This article introduced the application of high purity and high quality DRI in the fields of amorphous base material, atomized iron powder, powder superalloy, high purity and ultra-low carbon special metallurgy products, precision casting, super alloy and various iron-based alloys. It provides a reference for the high added value utilization of DRI.

  19. Technology and Development of Self-Reinforced Polymer Composites

    NASA Astrophysics Data System (ADS)

    Alcock, Ben; Peijs, Ton

    In recent years there has been an increasing amount of interest, both commercially and scientifically, in the emerging field of "self-reinforced polymer composites". These materials, which are sometimes also referred to as "single polymer composites", or "all-polymer composites", were first conceived in the 1970s, and are now beginning to appear in a range of commercial products. While high mechanical performance polymer fibres or tapes are an obvious precursor for composite development, various different technologies have been developed to consolidate these into two- or three-dimensional structures. This paper presents a review of the various processing techniques that have been reported in the literature for the manufacture of self-reinforced polymer composites from fibres or tapes of different polymers, and so exploit the fibre or tape performance in a commercial material or product.

  20. Preparation of pyrolysis reference samples: evaluation of a standard method using a tube furnace.

    PubMed

    Sandercock, P Mark L

    2012-05-01

    A new, simple method for the reproducible creation of pyrolysis products from different materials that may be found at a fire scene is described. A temperature programmable steady-state tube furnace was used to generate pyrolysis products from different substrates, including softwoods, paper, vinyl sheet flooring, and carpet. The temperature profile of the tube furnace was characterized, and the suitability of the method to reproducibly create pyrolysates similar to those found in real fire debris was assessed. The use of this method to create proficiency tests to realistically test an examiner's ability to interpret complex gas chromatograph-mass spectrometric fire debris data, and to create a library of pyrolsates generated from materials commonly found at a fire scene, is demonstrated. © 2011 American Academy of Forensic Sciences.

  1. Transparent Conducting Oxides—An Up-To-Date Overview

    PubMed Central

    Stadler, Andreas

    2012-01-01

    Transparent conducting oxides (TCOs) are electrical conductive materials with comparably low absorption of electromagnetic waves within the visible region of the spectrum. They are usually prepared with thin film technologies and used in opto-electrical apparatus such as solar cells, displays, opto-electrical interfaces and circuitries. Here, based on a modern database-system, aspects of up-to-date material selections and applications for transparent conducting oxides are sketched, and references for detailed information are given. As n-type TCOs are of special importance for thin film solar cell production, indium-tin oxide (ITO) and the reasonably priced aluminum-doped zinc oxide (ZnO:Al), are discussed with view on preparation, characterization and special occurrences. For completion, the recently frequently mentioned typical p-type delafossite TCOs are described as well, providing a variety of references, as a detailed discussion is not reasonable within an overview publication. PMID:28817002

  2. Quantitative Analysis of Plutonium Content in Particles Collected from a Certified Reference Material by Total Nuclear Reaction Energy (Q Value) Spectroscopy

    NASA Astrophysics Data System (ADS)

    Croce, M. P.; Hoover, A. S.; Rabin, M. W.; Bond, E. M.; Wolfsberg, L. E.; Schmidt, D. R.; Ullom, J. N.

    2016-08-01

    Microcalorimeters with embedded radioisotopes are an emerging category of sensor with advantages over existing methods for isotopic analysis of trace-level nuclear materials. For each nuclear decay, the energy of all decay products captured by the absorber (alpha particles, gamma rays, X-rays, electrons, daughter nuclei, etc.) is measured in one pulse. For alpha-decaying isotopes, this gives a measurement of the total nuclear reaction energy (Q value) and the spectra consist of well-separated, narrow peaks. We have demonstrated a simple mechanical alloying process to create an absorber structure consisting of a gold matrix with small inclusions of a radioactive sample. This absorber structure provides an optimized energy thermalization environment, resulting in high-resolution spectra with minimal tailing. We have applied this process to the analysis of particles collected from the surface of a plutonium metal certified reference material (CRM-126A from New Brunswick Laboratory) and demonstrated isotopic analysis by microcalorimeter Q value spectroscopy. Energy resolution from the Gaussian component of a Bortels function fit was 1.3 keV FWHM at 5244 keV. The collected particles were integrated directly into the detector absorber without any chemical processing. The ^{238}Pu/^{239}Pu and ^{240}Pu/^{239}Pu mass ratios were measured and the results confirmed against the certificate of analysis for the reference material. We also demonstrated inter-element analysis capability by measuring the ^{241}Am/^{239}Pu mass ratio.

  3. Stability evaluation of quality parameters for palm oil products at low temperature storage.

    PubMed

    Ramli, Nur Aainaa Syahirah; Mohd Noor, Mohd Azmil; Musa, Hajar; Ghazali, Razmah

    2018-07-01

    Palm oil is one of the major oils and fats produced and traded worldwide. The value of palm oil products is mainly influenced by their quality. According to ISO 17025:2005, accredited laboratories require a quality control procedure with respect to monitoring the validity of tests for determination of quality parameters. This includes the regular use of internal quality control using secondary reference materials. Unfortunately, palm oil reference materials are not currently available. To establish internal quality control samples, the stability of quality parameters needs to be evaluated. In the present study, the stability of quality parameters for palm oil products was examined over 10 months at low temperature storage (6 ± 2 °C). The palm oil products tested included crude palm oil (CPO); refined, bleached and deodorized (RBD) palm oil (RBDPO); RBD palm olein (RBDPOo); and RBD palm stearin (RBDPS). The quality parameters of the oils [i.e. moisture content, free fatty acid content (FFA), iodine value (IV), fatty acids composition (FAC) and slip melting point (SMP)] were determined prior to and throughout the storage period. The moisture, FFA, IV, FAC and SMP for palm oil products changed significantly (P < 0.05), whereas the moisture content for CPO, IV for RBDPO and RBDPOo, stearic acid composition for CPO and linolenic acid composition for CPO, RBDPO, RBDPOo and RBDPS did not (P > 0.05). The stability study indicated that the quality of the palm oil products was stable within the specified limits throughout the storage period at low temperature. The storage conditions preserved the quality of palm oil products throughout the storage period. These findings qualify the use of the palm oil products CPO, RBDPO, RBDPOo and RBDPS as control samples in the validation of test results. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  4. Bisphenol A polycarbonate as a reference material

    NASA Technical Reports Server (NTRS)

    Hilado, C. J.; Cumming, H. J.; Williams, J. B.

    1977-01-01

    Test methods require reference materials to standardize and maintain quality control. Various materials have been evaluated as possible reference materials, including a sample of bisphenol A polycarbonate without additives. Screening tests for relative toxicity under various experimental conditions were performed using male mice exposed to pyrolysis effluents over a 200-800 C temperature range. It was found that the bisphenol A polycarbonate served as a suitable reference material as it is available in large quantities, and does not significantly change with time.

  5. Investigation of a novel approach for the cross-linking characterization of SU-8 photoresist materials by means of optical dispersion measurements

    NASA Astrophysics Data System (ADS)

    Taudt, Ch.; Baselt, T.; Koch, E.; Hartmann, P.

    2014-03-01

    The increase in efficiency and precision in the production of semiconductor structures under the use of polymeric materials like SU-8 is crucial in securing the technological innovation within this industry. The manufacturing of structures on wafers demands a high quality of materials, tools and production processes. In particular, deviations in the materials' parameters (e.g. cross-linking state, density or mechanical properties) could lead to subsequent problems such as a reduced lifetime of structures and systems. In particular problems during the soft and post-exposure bake process can lead to an inhomogeneous distribution of material properties. This paper describes a novel approach for the characterization of SU-8 material properties in relation to a second epoxy-based material of different cross-linking by the measurement of optical dispersion within the material. A white-light interferometer was used. In particular the setup consisted of a white-light source, a Michelson-type interferometer and a spectrometer. The investigation of the dispersion characteristics was carried out by the detection of the equalization wavelength for different positions of the reference arm in a range from 400 to 900 nm. The measured time delay due to dispersion ranges from 850 to 1050 ps/m. For evaluation purposes a 200μm SU-8 sample was characterized in the described setup regarding its dispersion characteristics in relation to bulk epoxy material. The novel measurement approach allowed a fast and high-resolution material characterization for SU-8 micro structures which was suitable for integration in production lines. The outlook takes modifications of the experimental setup regarding on-wafer measurements into account.

  6. Characterization of a Recombinant Adeno-Associated Virus Type 2 Reference Standard Material

    PubMed Central

    Lock, Martin; McGorray, Susan; Auricchio, Alberto; Ayuso, Eduard; Beecham, E. Jeffrey; Blouin-Tavel, Véronique; Bosch, Fatima; Bose, Mahuya; Byrne, Barry J.; Caton, Tina; Chiorini, John A.; Chtarto, Abdelwahed; Clark, K. Reed; Conlon, Thomas; Darmon, Christophe; Doria, Monica; Douar, Anne; Flotte, Terence R.; Francis, Joyce D.; Francois, Achille; Giacca, Mauro; Korn, Michael T.; Korytov, Irina; Leon, Xavier; Leuchs, Barbara; Lux, Gabriele; Melas, Catherine; Mizukami, Hiroaki; Moullier, Philippe; Müller, Marcus; Ozawa, Keiya; Philipsberg, Tina; Poulard, Karine; Raupp, Christina; Rivière, Christel; Roosendaal, Sigrid D.; Samulski, R. Jude; Soltys, Steven M.; Surosky, Richard; Tenenbaum, Liliane; Thomas, Darby L.; van Montfort, Bart; Veres, Gabor; Wright, J. Fraser; Xu, Yili; Zelenaia, Olga; Zentilin, Lorena

    2010-01-01

    Abstract A recombinant adeno-associated virus serotype 2 Reference Standard Material (rAAV2 RSM) has been produced and characterized with the purpose of providing a reference standard for particle titer, vector genome titer, and infectious titer for AAV2 gene transfer vectors. Production and purification of the reference material were carried out by helper virus–free transient transfection and chromatographic purification. The purified bulk material was vialed, confirmed negative for microbial contamination, and then distributed for characterization along with standard assay protocols and assay reagents to 16 laboratories worldwide. Using statistical transformation and modeling of the raw data, mean titers and confidence intervals were determined for capsid particles ({X}, 9.18 × 1011 particles/ml; 95% confidence interval [CI], 7.89 × 1011 to 1.05 × 1012 particles/ml), vector genomes ({X}, 3.28 × 1010 vector genomes/ml; 95% CI, 2.70 × 1010 to 4.75 × 1010 vector genomes/ml), transducing units ({X}, 5.09 × 108 transducing units/ml; 95% CI, 2.00 × 108 to 9.60 × 108 transducing units/ml), and infectious units ({X}, 4.37 × 109 TCID50 IU/ml; 95% CI, 2.06 × 109 to 9.26 × 109 TCID50 IU/ml). Further analysis confirmed the identity of the reference material as AAV2 and the purity relative to nonvector proteins as greater than 94%. One obvious trend in the quantitative data was the degree of variation between institutions for each assay despite the relatively tight correlation of assay results within an institution. This relatively poor degree of interlaboratory precision and accuracy was apparent even though attempts were made to standardize the assays by providing detailed protocols and common reagents. This is the first time that such variation between laboratories has been thoroughly documented and the findings emphasize the need in the field for universal reference standards. The rAAV2 RSM has been deposited with the American Type Culture Collection and is available to the scientific community to calibrate laboratory-specific internal titer standards. Anticipated uses of the rAAV2 RSM are discussed. PMID:20486768

  7. Hybrid bandgap engineering for super-hetero-epitaxial semiconductor materials, and products thereof

    NASA Technical Reports Server (NTRS)

    Park, Yeonjoon (Inventor); Choi, Sang H. (Inventor); King, Glen C. (Inventor); Elliott, James R. (Inventor)

    2012-01-01

    "Super-hetero-epitaxial" combinations comprise epitaxial growth of one material on a different material with different crystal structure. Compatible crystal structures may be identified using a "Tri-Unity" system. New bandgap engineering diagrams are provided for each class of combination, based on determination of hybrid lattice constants for the constituent materials in accordance with lattice-matching equations. Using known bandgap figures for previously tested materials, new materials with lattice constants that match desired substrates and have the desired bandgap properties may be formulated by reference to the diagrams and lattice matching equations. In one embodiment, this analysis makes it possible to formulate new super-hetero-epitaxial semiconductor systems, such as systems based on group IV alloys on c-plane LaF.sub.3; group IV alloys on c-plane langasite; Group III-V alloys on c-plane langasite; and group II-VI alloys on c-plane sapphire.

  8. Copper as an antibacterial material in different facilities.

    PubMed

    Inkinen, J; Mäkinen, R; Keinänen-Toivola, M M; Nordström, K; Ahonen, M

    2017-01-01

    The present study was performed in real life settings in different facilities (hospital, kindergarten, retirement home, office building) with copper and copper alloy touch surface products (floor drain lids, toilet flush buttons, door handles, light switches, closet touch surfaces, corridor hand rails, front door handles and toilet support rails) in parallel to reference products. Pure copper surfaces supported lower total bacterial counts (16 ± 45 vs 105 ± 430 CFU cm -2 , n = 214, P < 0·001) and a lower occurrence of Staphylococcus aureus (2·6 vs 14%, n = 157, P < 0·01) and Gram-negatives (21 vs 34%, n = 214, P < 0·05) respectively than did reference surfaces, whereas the occurrence of enterococci (15%, n = 214, P > 0·05) was similar. The studied products could be assigned to three categories according to their bacterial loads as follows (P < 0·001): floor drain lids (300 ± 730 CFU cm -2 , n = 32), small area touch surfaces (8·0 ± 7·1 to 62 ± 160 CFU cm -2 , n = 90) and large area touch surfaces (1·1 ± 1·1 to 1·7 ± 2·4 CFU cm -2 , n = 92). In conclusion, copper touch surface products can function as antibacterial materials to reduce the bacterial load, especially on frequently touched small surfaces. The efficiency of copper as an antimicrobial material has been noted in laboratory studies and in the hospital environment. The present study further shows that copper exerted an antibacterial effect in different facilities, i.e. in a hospital, a kindergarten, an office building and in a retirement home for the elderly. The study suggests that copper has potential use as an antibacterial material and therefore might serve as a means to lower the incidence of transmission of infectious agents from inanimate surfaces in different facilities, with everyday functions. © 2016 The Society for Applied Microbiology.

  9. 40 CFR 1045.810 - What materials does this part reference?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Definitions and Other Reference Information § 1045.810 What materials does this part reference? Documents... material. Table 1 to this section lists material from the Society of Automotive Engineers that we have... the Society of Automotive Engineers, 400 Commonwealth Drive, Warrendale, PA 15096 or http://www.sae...

  10. Method and apparatus for assessing material properties of sheet-like materials

    DOEpatents

    Telschow, Kenneth L.; Deason, Vance A.

    2002-01-01

    Apparatus for producing an indication of a material property of a sheet-like material according to the present invention may comprise an excitation source for vibrating the sheet-like material to produce at least one traveling wave therein. A light source configured to produce an object wavefront and a reference wavefront directs the object wavefront toward the sheet-like material to produce a modulated object wavefront. A modulator operatively associated with the reference wavefront modulates the reference wavefront in synchronization with the traveling wave on the sheet-like material to produce a modulated reference wavefront. A sensing medium positioned to receive the modulated object wavefront and the modulated reference wavefront produces an image of the traveling wave in the sheet-like material, the image of the anti-symmetric traveling wave being related to a displacement amplitude of the anti-symmetric traveling wave over a two-dimensional area of the vibrating sheet-like material. A detector detects the image of the traveling wave in the sheet-like material.

  11. 21 CFR 320.26 - Guidelines on the design of a single-dose in vivo bioavailability or bioequivalence study.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 5 2011-04-01 2011-04-01 false Guidelines on the design of a single-dose in vivo bioavailability or bioequivalence study. 320.26 Section 320.26 Food and Drugs FOOD AND DRUG ADMINISTRATION... test product and the reference material should be administered to subjects in the fasting state, unless...

  12. JPRS Report, Science & Technology, USSR: Science & Technology Policy

    DTIC Science & Technology

    1988-09-23

    number of library personnel for preparing survey -analyt- ical references, but by equipping them with modern computer hardware for acquiring information...of manpower, material, technical, and financial resources and limits of capital investments and planning, surveying , and contractual work, which...USSR State Prize for the development and introduction of a technology of the production of shampoo from fish protein. During the period under review

  13. Automotive Stirling reference engine design report

    NASA Technical Reports Server (NTRS)

    1981-01-01

    The reference Stirling engine system is described which provides the best possible fuel economy while meeting or exceeding all other program objectives. The system was designed to meet the requirements of a 1984 Pontiac Phoenix (X-body). This design utilizes all new technology that can reasonably be expected to be developed by 1984 and that is judged to provide significant improvement, relative to development risk and cost. Topics covered include: (1) external heat system; (2) hot engine system; (3) cold engine system; (4) engine drive system; (5) power control system and auxiliaries; (6) engine instalation; (7) optimization and vehicle simulation; (8) engine materials; and (9) production cost analysis.

  14. Developing a new production host from a blueprint: Bacillus pumilus as an industrial enzyme producer.

    PubMed

    Küppers, Tobias; Steffen, Victoria; Hellmuth, Hendrik; O'Connell, Timothy; Bongaerts, Johannes; Maurer, Karl-Heinz; Wiechert, Wolfgang

    2014-03-24

    Since volatile and rising cost factors such as energy, raw materials and market competitiveness have a significant impact on the economic efficiency of biotechnological bulk productions, industrial processes need to be steadily improved and optimized. Thereby the current production hosts can undergo various limitations. To overcome those limitations and in addition increase the diversity of available production hosts for future applications, we suggest a Production Strain Blueprinting (PSB) strategy to develop new production systems in a reduced time lapse in contrast to a development from scratch.To demonstrate this approach, Bacillus pumilus has been developed as an alternative expression platform for the production of alkaline enzymes in reference to the established industrial production host Bacillus licheniformis. To develop the selected B. pumilus as an alternative production host the suggested PSB strategy was applied proceeding in the following steps (dedicated product titers are scaled to the protease titer of Henkel's industrial production strain B. licheniformis at lab scale): Introduction of a protease production plasmid, adaptation of a protease production process (44%), process optimization (92%) and expression optimization (114%). To further evaluate the production capability of the developed B. pumilus platform, the target protease was substituted by an α-amylase. The expression performance was tested under the previously optimized protease process conditions and under subsequently adapted process conditions resulting in a maximum product titer of 65% in reference to B. licheniformis protease titer. In this contribution the applied PSB strategy performed very well for the development of B. pumilus as an alternative production strain. Thereby the engineered B. pumilus expression platform even exceeded the protease titer of the industrial production host B. licheniformis by 14%. This result exhibits a remarkable potential of B. pumilus to be the basis for a next generation production host, since the strain has still a large potential for further genetic engineering. The final amylase titer of 65% in reference to B. licheniformis protease titer suggests that the developed B. pumilus expression platform is also suitable for an efficient production of non-proteolytic enzymes reaching a final titer of several grams per liter without complex process modifications.

  15. Environmental and sustainability ethics in supply chain management.

    PubMed

    Beamon, Benita M

    2005-04-01

    Environmentally Conscious Supply Chain Management (ECSCM refers to the control exerted over all immediate and eventual environmental effects of products and processes associated with converting raw materials into final products. While much work has been done in this area, the focus has traditionally been on either: product recovery (recycling, remanufacturing, or re-use) or the product design function only (e.g., design for environment). Environmental considerations in manufacturing are often viewed as separate from traditional, value-added considerations. However, the case can be made that professional engineers have an ethical responsibility to consider the immediate and eventual environmental impacts of products and processes that they design and/or manage. This paper describes ECSCM as a component of engineering ethics, and highlights the major issues associated with ethical decision-making in supply chain management.

  16. Studies on Application of Aroma Finish on Silk Fabric

    NASA Astrophysics Data System (ADS)

    Hipparagi, Sanganna Aminappa; Srinivasa, Thirumalappa; Das, Brojeswari; Naik, Subhas Venkatappa; Purushotham, Serampur Parappa

    2016-10-01

    Aromatic treatments on textiles have gained importance in the recent years. In the present article work has been done on fragrance finish application on silk material. Silk is an expensive natural fibre used for apparel purpose and known for its feel and appeal. Incorporation of fragrance material in silk product, will add more value to it. Present work focuses to impart durable aroma finish for silk products to be home washed or subjected to dry cleaning. Microencapsulated aroma chemical has been used for the treatment. Impregnation method, Exhaust method, Dip-Pad-Dry method and Spray method have been used to see the influence of application method on the uptake and performance. Evaluation of the aroma treated material has been done through subjective evaluation as per Odor Intensity Reference Scaling (OIRS). Effect of the aroma finishing on the physical properties of the fabric has also been studied. No adverse effect has been observed on the stiffness of the fabric after the aroma treatment.

  17. Synthesis Methods of Carbon Nanotubes and Related Materials

    PubMed Central

    Szabó, Andrea; Perri, Caterina; Csató, Anita; Giordano, Girolamo; Vuono, Danilo; Nagy, János B.

    2010-01-01

    The challenge on carbon nanotubes is still the subject of many research groups. While in the first years the focus was on the new synthesis methods, new carbon sources and support materials, recently, the application possibilities are the principal arguments of the studies. The three main synthesis methods discussed in this review are the arc discharge, the laser ablation and the chemical vapour deposition (CVD) with a special regard to the latter one. In the early stage of the nanotube production the first two methods were utilized mainly for the production of SWNTs while the third one produced mainly MWNTs. The principle of CVD is the decomposition of various hydrocarbons over transition metal supported catalyst. Single-walled (SWNT), multi-walled (MWNT) and coiled carbon nanotubes are produced. In some case, interesting carbonaceous materials are formed during the synthesis process, such as bamboo-like tubes, onions, horn-like structures. In this paper, we refer to the progresses made in the field of the synthesis techniques of carbon nanotubes in the last decade.

  18. WHO Expert Committee on Specifications for Pharmaceutical Preparations.

    PubMed

    2005-01-01

    This report presents the recommendations of an international group of experts convened by the World Health Organization to consider matters concerning the quality assurance of pharmaceuticals and specifications for drug substances and dosage forms. Of particular relevance to drug regulatory authorities and pharmaceutical manufacturers, this report discusses the monographs on antiretrovirals proposed for inclusion in The International Pharmacopoeia and specifications for radiopharmaceuticals, quality specifications for antituberculosis drugs and the revision of the monograph on artemisinin derivatives, as well as quality control of reference materials, good manufacturing practices (GMP), inspection, distribution and trade and other aspects of quality assurance of pharmaceuticals, and regulatory issues. The report is complemented by a number of annexes, including an amendment to good manufacturing practices: main principles regarding the requirement for the sampling of starting materials, guidelines on good manufacturing practices regarding water for pharmaceutical use, guidelines on the sampling of pharmaceutical products and related materials and draft guidelines for registration of fixed-dose combination medicinal products.

  19. Potential of the polymer poly-[2-(tert-butylamino) methylstyrene] as antimicrobial packaging material for meat products.

    PubMed

    Dohlen, S; Braun, C; Brodkorb, F; Fischer, B; Ilg, Y; Kalbfleisch, K; Lorenz, R; Robers, O; Kreyenschmidt, M; Kreyenschmidt, J

    2016-10-01

    The objective of the study was to investigate the antimicrobial potential of a new SAM(®) polymer poly(TBAMS) as packaging material for meat products. The influence of temperature, time and product factors on the antimicrobial activity of poly(TBAMS) against different bacteria was determined using a modified test method based on the Japanese Industrial Standard 2801:2000. Results showed a significant reduction in bacterial counts on poly(TBAMS) compared with the reference material of several meat-specific micro-organisms after 24 h at 7°C. Bacterial counts of Staphylococcus aureus, Listeria monocytogenes, Lactobacillus spp., Brochothrix thermosphacta and Escherichia coli were reduced by >4·0 log10  units. Pseudomonas fluorescens was less sensitive to poly(TBAMS) within 24 h between 2 and 7°C. Prolonging the storage time to 48 h, however, resulted in an increased reduction rate. Furthermore, antimicrobial activity was also observed if meat components in the form of meat extract, meat juice or bovine serum albumin protein were present. Antimicrobial activity was also achieved if inoculated with mixed cultures. Poly(TBAMS) showed antimicrobial properties under conditions typical for meat supply chains. Poly(TBAMS) bears a high potential to increase safety and shelf life of meat products. © 2016 The Society for Applied Microbiology.

  20. Immunoassay as an analytical tool in agricultural biotechnology.

    PubMed

    Grothaus, G David; Bandla, Murali; Currier, Thomas; Giroux, Randal; Jenkins, G Ronald; Lipp, Markus; Shan, Guomin; Stave, James W; Pantella, Virginia

    2006-01-01

    Immunoassays for biotechnology engineered proteins are used by AgBiotech companies at numerous points in product development and by feed and food suppliers for compliance and contractual purposes. Although AgBiotech companies use the technology during product development and seed production, other stakeholders from the food and feed supply chains, such as commodity, food, and feed companies, as well as third-party diagnostic testing companies, also rely on immunoassays for a number of purposes. The primary use of immunoassays is to verify the presence or absence of genetically modified (GM) material in a product or to quantify the amount of GM material present in a product. This article describes the fundamental elements of GM analysis using immunoassays and especially its application to the testing of grains. The 2 most commonly used formats are lateral flow devices (LFD) and plate-based enzyme-linked immunosorbent assays (ELISA). The main applications of both formats are discussed in general, and the benefits and drawbacks are discussed in detail. The document highlights the many areas to which attention must be paid in order to produce reliable test results. These include sample preparation, method validation, choice of appropriate reference materials, and biological and instrumental sources of error. The article also discusses issues related to the analysis of different matrixes and the effects they may have on the accuracy of the immunoassays.

  1. Reproducibility of polycarbonate reference material in toxicity evaluation

    NASA Technical Reports Server (NTRS)

    Hilado, C. J.; Huttlinger, P. A.

    1981-01-01

    A specific lot of bisphenol A polycarbonate has been used for almost four years as the reference material for the NASA-USF-PSC toxicity screening test method. The reproducibility of the test results over this period of time indicate that certain plastics may be more suitable reference materials than the more traditional cellulosic materials.

  2. Evaluating the quality of a cell counting measurement process via a dilution series experimental design.

    PubMed

    Sarkar, Sumona; Lund, Steven P; Vyzasatya, Ravi; Vanguri, Padmavathy; Elliott, John T; Plant, Anne L; Lin-Gibson, Sheng

    2017-12-01

    Cell counting measurements are critical in the research, development and manufacturing of cell-based products, yet determining cell quantity with accuracy and precision remains a challenge. Validating and evaluating a cell counting measurement process can be difficult because of the lack of appropriate reference material. Here we describe an experimental design and statistical analysis approach to evaluate the quality of a cell counting measurement process in the absence of appropriate reference materials or reference methods. The experimental design is based on a dilution series study with replicate samples and observations as well as measurement process controls. The statistical analysis evaluates the precision and proportionality of the cell counting measurement process and can be used to compare the quality of two or more counting methods. As an illustration of this approach, cell counting measurement processes (automated and manual methods) were compared for a human mesenchymal stromal cell (hMSC) preparation. For the hMSC preparation investigated, results indicated that the automated method performed better than the manual counting methods in terms of precision and proportionality. By conducting well controlled dilution series experimental designs coupled with appropriate statistical analysis, quantitative indicators of repeatability and proportionality can be calculated to provide an assessment of cell counting measurement quality. This approach does not rely on the use of a reference material or comparison to "gold standard" methods known to have limited assurance of accuracy and precision. The approach presented here may help the selection, optimization, and/or validation of a cell counting measurement process. Published by Elsevier Inc.

  3. Copy number ratios determined by two digital polymerase chain reaction systems in genetically modified grains

    NASA Astrophysics Data System (ADS)

    Pérez Urquiza, M.; Acatzi Silva, A. I.

    2014-02-01

    Three certified reference materials produced from powdered seeds to measure the copy number ratio sequences of p35S/hmgA in maize containing MON 810 event, p35S/Le1 in soybeans containing GTS 40-3-2 event and DREB1A/acc1 in wheat were produced according to the ISO Guides 34 and 35. In this paper, we report digital polymerase chain reaction (dPCR) protocols, performance parameters and results of copy number ratio content of genetically modified organisms (GMOs) in these materials using two new dPCR systems to detect and quantify molecular deoxyribonucleic acid: the BioMark® (Fluidigm) and the OpenArray® (Life Technologies) systems. These technologies were implemented at the National Institute of Metrology in Mexico (CENAM) and in the Reference Center for GMO Detection from the Ministry of Agriculture (CNRDOGM), respectively. The main advantage of this technique against the more-used quantitative polymerase chain reaction (qPCR) is that it generates an absolute number of target molecules in the sample, without reference to standards or an endogenous control, which is very useful when not much information is available for new developments or there are no standard reference materials in the market as in the wheat case presented, or when it was not possible to test the purity of seeds as in the maize case presented here. Both systems reported enhanced productivity, increased reliability and reduced instrument footprint. In this paper, the performance parameters and uncertainty of measurement obtained with both systems are presented and compared.

  4. Palm-Based Standard Reference Materials for Iodine Value and Slip Melting Point

    PubMed Central

    Tarmizi, Azmil Haizam Ahmad; Lin, Siew Wai; Kuntom, Ainie

    2008-01-01

    This work described study protocols on the production of Palm-Based Standard Reference Materials for iodine value and slip melting point. Thirty-three laboratories collaborated in the inter-laboratory proficiency tests for characterization of iodine value, while thirty-two laboratories for characterization of slip melting point. The iodine value and slip melting point of palm oil, palm olein and palm stearin were determined in accordance to MPOB Test Methods p3.2:2004 and p4.2:2004, respectively. The consensus values and their uncertainties were based on the acceptability of statistical agreement of results obtained from collaborating laboratories. The consensus values and uncertainties for iodine values were 52.63 ± 0.14 Wijs in palm oil, 56.77 ± 0.12 Wijs in palm olein and 33.76 ± 0.18 Wijs in palm stearin. For the slip melting points, the consensus values and uncertainties were 35.6 ± 0.3 °C in palm oil, 22.7 ± 0.4 °C in palm olein and 53.4 ± 0.2 °C in palm stearin. Repeatability and reproducibility relative standard deviations were found to be good and acceptable, with values much lower than that of 10%. Stability of Palm-Based Standard Reference Materials remained stable at temperatures of −20 °C, 0 °C, 6 °C and 24 °C upon storage for one year. PMID:19609396

  5. 3D printing with polymers: Challenges among expanding options and opportunities.

    PubMed

    Stansbury, Jeffrey W; Idacavage, Mike J

    2016-01-01

    Additive manufacturing, which is more colloquially referred to as 3D printing, is quickly approaching mainstream adoption as a highly flexible processing technique that can be applied to plastic, metal, ceramic, concrete and other building materials. However, taking advantage of the tremendous versatility associated with in situ photopolymerization as well as the ability to select from a variety of preformed processible polymers, 3D printing predominantly targets the production of polymeric parts and models. The goal of this review is to connect the various additive manufacturing techniques with the monomeric and polymeric materials they use while highlighting emerging material-based developments. Modern additive manufacturing technology was introduced approximately three decades ago but this review compiles recent peer-reviewed literature reports to demonstrate the evolution underway with respect to the various building techniques that differ significantly in approach as well as the new variations in polymer-based materials being employed. Recent growth of 3D printing has been dramatic and the ability of the various platform technologies to expand from rapid production prototypic models to the greater volume of readily customizable production of working parts is critical for continued high growth rates. This transition to working part production is highly dependent on adapting materials that deliver not only the requisite design accuracy but also the physical and mechanical properties necessary for the application. With the weighty distinction of being called the next industrial revolution, 3D printing technologies is already altering many industrial and academic operations including changing models for future healthcare delivery in medicine and dentistry. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  6. Production and certification of NIST Standard Reference Material 2372 Human DNA Quantitation Standard.

    PubMed

    Kline, Margaret C; Duewer, David L; Travis, John C; Smith, Melody V; Redman, Janette W; Vallone, Peter M; Decker, Amy E; Butler, John M

    2009-06-01

    Modern highly multiplexed short tandem repeat (STR) assays used by the forensic human-identity community require tight control of the initial amount of sample DNA amplified in the polymerase chain reaction (PCR) process. This, in turn, requires the ability to reproducibly measure the concentration of human DNA, [DNA], in a sample extract. Quantitative PCR (qPCR) techniques can determine the number of intact stretches of DNA of specified nucleotide sequence in an extremely small sample; however, these assays must be calibrated with DNA extracts of well-characterized and stable composition. By 2004, studies coordinated by or reported to the National Institute of Standards and Technology (NIST) indicated that a well-characterized, stable human DNA quantitation certified reference material (CRM) could help the forensic community reduce within- and among-laboratory quantitation variability. To ensure that the stability of such a quantitation standard can be monitored and that, if and when required, equivalent replacement materials can be prepared, a measurement of some stable quantity directly related to [DNA] is required. Using a long-established conventional relationship linking optical density (properly designated as decadic attenuance) at 260 nm with [DNA] in aqueous solution, NIST Standard Reference Material (SRM) 2372 Human DNA Quantitation Standard was issued in October 2007. This SRM consists of three quite different DNA extracts: a single-source male, a multiple-source female, and a mixture of male and female sources. All three SRM components have very similar optical densities, and thus very similar conventional [DNA]. The materials perform very similarly in several widely used gender-neutral assays, demonstrating that the combination of appropriate preparation methods and metrologically sound spectrophotometric measurements enables the preparation and certification of quantitation [DNA] standards that are both maintainable and of practical utility.

  7. Nicotine, acetanilide and urea multi-level2H-,13C- and15N-abundance reference materials for continuous-flow isotope ratio mass spectrometry

    USGS Publications Warehouse

    Schimmelmann, A.; Albertino, A.; Sauer, P.E.; Qi, H.; Molinie, R.; Mesnard, F.

    2009-01-01

    Accurate determinations of stable isotope ratios require a calibration using at least two reference materials with different isotopic compositions to anchor the isotopic scale and compensate for differences in machine slope. Ideally, the S values of these reference materials should bracket the isotopic range of samples with unknown S values. While the practice of analyzing two isotopically distinct reference materials is common for water (VSMOW-SLAP) and carbonates (NBS 19 and L-SVEC), the lack of widely available organic reference materials with distinct isotopic composition has hindered the practice when analyzing organic materials by elemental analysis/isotope ratio mass spectrometry (EA-IRMS). At present only L-glutamic acids USGS40 and USGS41 satisfy these requirements for ??13C and ??13N, with the limitation that L-glutamic acid is not suitable for analysis by gas chromatography (GC). We describe the development and quality testing of (i) four nicotine laboratory reference materials for on-line (i.e. continuous flow) hydrogen reductive gas chromatography-isotope ratio mass-spectrometry (GC-IRMS), (ii) five nicotines for oxidative C, N gas chromatography-combustion-isotope ratio mass-spectrometry (GC-C-IRMS, or GC-IRMS), and (iii) also three acetanilide and three urea reference materials for on-line oxidative EA-IRMS for C and N. Isotopic off-line calibration against international stable isotope measurement standards at Indiana University adhered to the 'principle of identical treatment'. The new reference materials cover the following isotopic ranges: ??2Hnicotine -162 to -45%o, ??13Cnicotine -30.05 to +7.72%, ?? 15Nnicotine -6.03 to +33.62%; ??15N acetanilide +1-18 to +40.57%; ??13Curea -34.13 to +11.71%, ??15Nurea +0.26 to +40.61% (recommended ?? values refer to calibration with NBS 19, L-SVEC, IAEA-N-1, and IAEA-N-2). Nicotines fill a gap as the first organic nitrogen stable isotope reference materials for GC-IRMS that are available with different ??13N values. Comparative ??13C and ??15N on-line EA-IRMS data from 14 volunteering laboratories document the usefulness and reliability of acetanilides and ureas as EA-IRMS reference materials.

  8. A novel non-sequencing approach for rapid authentication of Testudinis Carapax et Plastrum and Trionycis Carapax by species-specific primers

    PubMed Central

    Yu, Pingtian; Lu, Yi; Jiao, Zhaoqun; Chen, Liqun; Zhou, Ying; Shen, Yuping; Jia, Xiaobin

    2018-01-01

    A novel non-sequencing approach was developed to detect short DNA fragments (ca 100 bp) for rapid authentication of two natural products, namely Testudinis Carapax et Plastrum and Trionycis Carapax, based on the difference in mitochondrial genome. Five specifically designed primer reactions were established to target species for reliable identification of their commercial products. They were confirmed to have a high level of inter-species-specificity and good intra-species stability. The limit of detection was estimated to be 1 ng of genomes for all of five assays. Also, the validation results demonstrated that the raw materials and processed products in addition to some of the highly processed products can be conveniently authenticated with good sensitivity and precision by this newly proposed approach. Especially, when reference sample mixtures were assayed, these primer sets have still performed well but not the prevailing COI barcoding technology. These could assist in the discrimination and identification of other animal-derived medicines for their form of raw material, the pulverized and the complex. PMID:29765667

  9. Leaching from solid waste incineration ashes used in cement-treated base layers for pavements.

    PubMed

    Cai, Z; Bager, Dirch H; Christensen, T H

    2004-01-01

    Waste incineration bottom ash and treated flue gas cleaning products mixed with 2.5% of cement (50 kg/m3) were tested in the laboratory in terms of compressive strength and tank leaching tests over a 64-day period. Although the material displayed lower mechanical strength than a reference concrete, the strength still was sufficient for use as a base layer for roads. The metal content in the incineration-residue-based specimens was up to 100 times higher than in the reference concrete, suggesting that the mixed waste incineration residue should be used only for dedicated purposes. The leaching of Cl and Na was increased by a factor of 20-100 from the incineration-residue-based specimens as compared to the reference, while the leaching of K, Ca and SO4 was increased by a factor of 2-10. The leaching of heavy metals was also higher from the incineration-residue-based specimens than from the reference with respect to Cu (50 times), Cd, Pb and Zn (5 times), but not with respect to Cr and Ni. The leaching curves did only allow for a closer evaluation of the leaching process in a few cases. The physical retention of the constituents seemed to be the same in the reference as in the incineration-residue-based specimens. Heavy metal leaching was limited by enhanced chemical retention in the incineration-residue-specimens as compared to the reference. Since no quality criteria in terms of leaching from a monolithic material are currently available, the leaching issue must be evaluated case by case.

  10. [Monitoring method of extraction process for Schisandrae Chinensis Fructus based on near infrared spectroscopy and multivariate statistical process control].

    PubMed

    Xu, Min; Zhang, Lei; Yue, Hong-Shui; Pang, Hong-Wei; Ye, Zheng-Liang; Ding, Li

    2017-10-01

    To establish an on-line monitoring method for extraction process of Schisandrae Chinensis Fructus, the formula medicinal material of Yiqi Fumai lyophilized injection by combining near infrared spectroscopy with multi-variable data analysis technology. The multivariate statistical process control (MSPC) model was established based on 5 normal batches in production and 2 test batches were monitored by PC scores, DModX and Hotelling T2 control charts. The results showed that MSPC model had a good monitoring ability for the extraction process. The application of the MSPC model to actual production process could effectively achieve on-line monitoring for extraction process of Schisandrae Chinensis Fructus, and can reflect the change of material properties in the production process in real time. This established process monitoring method could provide reference for the application of process analysis technology in the process quality control of traditional Chinese medicine injections. Copyright© by the Chinese Pharmaceutical Association.

  11. [Hygienic study and evaluation of textile materials with reduced combustibility with reference to the use of the new anti-inflammable preparations Pyrofix 2 and Torflam].

    PubMed

    Uzunova, S; Baĭnova, A; Iordanova, I; Dolova, D

    1986-01-01

    The new anti-flammable preparations, proposed by the Higher Chemical Technology Institute (Sofia), were studied, namely: Pyrofix 2--for treatment of textile materials and Torflam--for production of anti-inflammable polyester fibres. The following parameters were studied: skin-irritating and skin-sensitizing effect of both preparations, skin toxic effect of Pyrofix 2 and migration of chemicals from the anti-inflammable textile materials (from the composition of the preparations used). The results obtained revealed the absence of skin-irritating and skin-sensitizing effect of both preparations and cumulative dermal toxicity of Pyrofix 2. The textile materials with reduced combustibility are chemically stable and do not release compounds in the contact aqueous medium, imitating the underclothes space. Formaldehyde from recipe for the treatment of Pyrofix 2 migrates in the air environment. In conclusion, Pyrofix 2 could be applied for the final anti-inflammable treatment of the textile materials for industrial needs, working garments and everyday textile (with the elimination of formaldehyde compound from the recipe). Torflam could be used in the production of anti-inflammable polyester fibres for textile materials intended for industry and everyday life without immediate contact with the skin of the consumers.

  12. The algorithm of verification of welding process for plastic pipes

    NASA Astrophysics Data System (ADS)

    Rzasinski, R.

    2017-08-01

    The study analyzes the process of butt welding of PE pipes in terms of proper selection of connector parameters. The process was oriented to the elements performed as a series of types of pipes. Polymeric materials commonly referred to as polymers or plastics, synthetic materials are produced from oil products in the polyreaction compounds of low molecular weight, called monomers. During the polyreactions monomers combine to build a macromolecule material monomer named with the prefix poly polypropylene, polyethylene or polyurethane, creating particles in solid state on the order of 0,2 to 0,4 mm. Finished products from polymers of virtually any shape and size are obtained by compression molding, injection molding, extrusion, laminating, centrifugal casting, etc. Weld can only be a thermoplastic that softens at an elevated temperature, and thus can be connected via a clamp. Depending on the source and method of supplying heat include the following welding processes: welding contact, radiant welding, friction welding, dielectric welding, ultrasonic welding. The analysis will be welding contact. In connection with the development of new generation of polyethylene, and the production of pipes with increasing dimensions (diameter, wall thickness) is important to select the correct process.

  13. Green Toxicology: a strategy for sustainable chemical and material development.

    PubMed

    Crawford, Sarah E; Hartung, Thomas; Hollert, Henner; Mathes, Björn; van Ravenzwaay, Bennard; Steger-Hartmann, Thomas; Studer, Christoph; Krug, Harald F

    2017-01-01

    Green Toxicology refers to the application of predictive toxicology in the sustainable development and production of new less harmful materials and chemicals, subsequently reducing waste and exposure. Built upon the foundation of "Green Chemistry" and "Green Engineering", "Green Toxicology" aims to shape future manufacturing processes and safe synthesis of chemicals in terms of environmental and human health impacts. Being an integral part of Green Chemistry, the principles of Green Toxicology amplify the role of health-related aspects for the benefit of consumers and the environment, in addition to being economical for manufacturing companies. Due to the costly development and preparation of new materials and chemicals for market entry, it is no longer practical to ignore the safety and environmental status of new products during product development stages. However, this is only possible if toxicologists and chemists work together early on in the development of materials and chemicals to utilize safe design strategies and innovative in vitro and in silico tools. This paper discusses some of the most relevant aspects, advances and limitations of the emergence of Green Toxicology from the perspective of different industry and research groups. The integration of new testing methods and strategies in product development, testing and regulation stages are presented with examples of the application of in silico, omics and in vitro methods. Other tools for Green Toxicology, including the reduction of animal testing, alternative test methods, and read-across approaches are also discussed.

  14. Biogenic SeNPs from Bacillus mycoides SelTE01 and Stenotrophomonas maltophilia SelTE02: Characterization with reference to their associated organic coating

    NASA Astrophysics Data System (ADS)

    Piacenza, Elena; Bulgarini, Alessandra; Lampis, Silvia; Vallini, Giovanni; Turner, Raymond J.

    2017-08-01

    The exploitation of biological systems (i.e. plants, fungi and bacteria) for the production of nanomaterials relies on their ability to bioconvert toxic metal(loid) ions into their less toxic and bioavailable elemental states forming mainly nanoparticles (NPs) or nanorods (NRs). Further, these methods of nanomaterial production are nowadays recognized as eco-friendly alternatives to the chemical synthesis processes. A common feature among the so-called biogenic nanomaterials is the presence of an organic layer surrounding them. However, we are just learning the existing relation between biogenic nanostructures and their organic material. Our work is focused on the study of bacterial strains for the production of selenium nanoparticles (SeNPs) as end product of selenite (SeO32 -) bioconversion. In this context, our previous reports described the ability of two bacteria, namely Bacillus mycoides SelTE01 and Stenotrophomonas maltophilia SelTE02, to generate SeNPs, which were surrounded by organic material. Here, the potential role of this organic material as stabilizing agent of SeNPs was investigated altering both the bacteria cells culturing and the SeNPs extraction procedure, in order to understand the interaction between these two elements in suspension. As a result, SeNPs produced by both bacterial strains showed the tendency to aggregate when subjected to the treatments tested, suggesting an involvement of the surrounding organic material in their stabilization in suspension.

  15. [Development of the certified reference material of mercury in lyophilized human urine].

    PubMed

    Zhao, Wei; Zhang, Fu-gang; DU, Hui-fang; Pan, Ya-juan; Yan, Hui-fang

    2011-02-01

    To develop the certified reference material of mercury in lyophilized human urine. Human urine samples from normal level mercury districts were filtered, homogenized, dispensed, lyophilized and radio-sterilized. Homogeneity test, stability inspection and certification were conducted using a atom fluorescence spectrophotometric method. The physical and chemical stability of the certified reference material were assessed for 18 months. The certified values are based on analysis made by three independent laboratories. The certified values are as follows: low level was (35.6 ± 2.1) µg/L, high level was (50.5 ± 3.0) µg/L. The certified reference material of mercury in lyophilized human urine in this research reached the national certified reference material requirements and could be used for the quality control.

  16. Design Engineering of Biomaterials for Medical Devices

    NASA Astrophysics Data System (ADS)

    Hill, David

    1998-10-01

    Written by an exceptionally experienced author in the area of medical equipment product design, this text presents a comprehensive overview of such sound principles and state-of-the-art techniques covering a whole host of material types, biocompatability, the design process and future trends within this exciting field. An all-in-one reference text, concise and easy-to-read. Wide audience appeal, from industry professionals to students of design.

  17. Reference Materials: Critical Importance to the Infant Formula Industry.

    PubMed

    Wargo, Wayne F

    2017-09-01

    Infant formula is one of the most regulated foods in the world. It has advanced in complexity over the years as a result of numerous research innovations. To ensure product safety and quality, analytical technologies have also had to advance to keep pace. Given the rigorous performance demands expected of these methods and the ever-growing array of complex matrixes, there is the potential for gaps to exist in current Official MethodsSM and other recognized international methods for infant formula and adult nutritionals. Food safety concerns, particularly for infants, drive the need for extensive testing by manufacturers and regulators. The net effect is the potential for an increase in time- and resource-consuming regulatory disputes. In an effort to mitigate such costly activities, AOAC INTERNATIONAL, under the direction of the Infant Formula Council of America-a trade association of manufacturers and marketers of formulated nutritional products-agreed to establish voluntary consensus Standard Method Performance Requirements, and, ultimately, to identify and publish globally recognized, fit-for-purpose standard methods. To accomplish this task, nutritional reference materials (RMs), representing all major commercially available nutritional formulations, were (and continue to be) a critical necessity. In this paper, various types of RMs will be defined, followed by review and discussion of their importance to the infant formula industry.

  18. Detection and traceability of genetically modified organisms in the food production chain.

    PubMed

    Miraglia, M; Berdal, K G; Brera, C; Corbisier, P; Holst-Jensen, A; Kok, E J; Marvin, H J P; Schimmel, H; Rentsch, J; van Rie, J P P F; Zagon, J

    2004-07-01

    Both labelling and traceability of genetically modified organisms are current issues that are considered in trade and regulation. Currently, labelling of genetically modified foods containing detectable transgenic material is required by EU legislation. A proposed package of legislation would extend this labelling to foods without any traces of transgenics. These new legislations would also impose labelling and a traceability system based on documentation throughout the food and feed manufacture system. The regulatory issues of risk analysis and labelling are currently harmonised by Codex Alimentarius. The implementation and maintenance of the regulations necessitates sampling protocols and analytical methodologies that allow for accurate determination of the content of genetically modified organisms within a food and feed sample. Current methodologies for the analysis of genetically modified organisms are focused on either one of two targets, the transgenic DNA inserted- or the novel protein(s) expressed- in a genetically modified product. For most DNA-based detection methods, the polymerase chain reaction is employed. Items that need consideration in the use of DNA-based detection methods include the specificity, sensitivity, matrix effects, internal reference DNA, availability of external reference materials, hemizygosity versus homozygosity, extrachromosomal DNA, and international harmonisation. For most protein-based methods, enzyme-linked immunosorbent assays with antibodies binding the novel protein are employed. Consideration should be given to the selection of the antigen bound by the antibody, accuracy, validation, and matrix effects. Currently, validation of detection methods for analysis of genetically modified organisms is taking place. In addition, new methodologies are developed, including the use of microarrays, mass spectrometry, and surface plasmon resonance. Challenges for GMO detection include the detection of transgenic material in materials with varying chromosome numbers. The existing and proposed regulatory EU requirements for traceability of genetically modified products fit within a broader tendency towards traceability of foods in general and, commercially, towards products that can be distinguished from each other. Traceability systems document the history of a product and may serve the purpose of both marketing and health protection. In this framework, segregation and identity preservation systems allow for the separation of genetically modified and non-modified products from "farm to fork". Implementation of these systems comes with specific technical requirements for each particular step of the food processing chain. In addition, the feasibility of traceability systems depends on a number of factors, including unique identifiers for each genetically modified product, detection methods, permissible levels of contamination, and financial costs. In conclusion, progress has been achieved in the field of sampling, detection, and traceability of genetically modified products, while some issues remain to be solved. For success, much will depend on the threshold level for adventitious contamination set by legislation. Copryright 2004 Elsevier Ltd.

  19. Outgassing Data for Selecting Spacecraft Materials

    NASA Technical Reports Server (NTRS)

    Campbell, William A., Jr.; Scialdone, John J.

    1993-01-01

    This tenth compilation of outgassing data of materials intended for spacecraft use supersedes Reference Publication 1124, Revision 2, November 1990. The data were obtained at the Goddard Space Flight Center (GSFC), utilizing equipment developed at Stanford Research Institute (SRI) under contract to the Jet Propulsion Laboratory (JPL). SRI personnel developed an apparatus for determining the mass loss in vacuum and for collecting the outgassed products. The outgassing data have been presented in three different ways in order to facilitate material selection. In Section A, the materials are divided by category into the 18 probable uses, such as adhesives, greases, paints, potting compounds, and so forth. In Section B, all the materials contained in Section A are listed in alphabetical order by the manufacturer's identification. In Section C, the only materials listed are those having 'Total Mass Loss' (TML) and Collected Volatile Condensable Materials (CVCM) equal to or lower than a maximum 1.0 percent TML and a maximum 0.10 percent CVCM. These are grouped by use, as in Section A.

  20. [Questionnaire studies on the vital situation and nutritional habits of students].

    PubMed

    Przybulewska, Krystyna; Janda, Katarzyna

    2004-01-01

    Results of questionnaire studies carried out in 2001/2002 among 230 students of University of Agriculture in Szczecin were presented. It served for assessing their material and living situation during studying at the University. Women and people originating from cities dominated in studied group of respondents. Probably, there is a decreasing tendency referring to attending the University by country people. Residence during studying depended on the year of education and origin of respondents. Last-year students and country people were more often placed in hostel. Material help in a form of social scholarship was more often assigned to country youth, and scientific grants were more frequently given to fifth-year students. No finance help of student's families made they undertook a part-time job that was made more often by final-year students. Significant differences referring to consumption customs often depended on sex. Students themselves most often prepared meals, including dinners. Only small per cent (12%) of students went to canteens, milk bars or other restaurants. Almost one-third of respondents fed irregularly. One-dish dinners consisting most often of purchased or earlier prepared semi-products dominated. Majority of students declared feeding meat, poultry, and sweets at least once a week, as well as fish--at least once a month. Every second person declared everyday consumption of fruit and vegetables, milk and its products as well as several cups of coffee daily; it referred more often to women. Most of respondents occasionally consumed sprinkle, low-alcoholic beverages and snacks in a form of chips and nuts, but they were more often men.

  1. Some possible reference materials for fire toxicity tests

    NASA Technical Reports Server (NTRS)

    Hilado, C. J.; Solis, A. N.

    1977-01-01

    Suitable reference materials need to be selected in order to standardize any test method. The evaluation of cotton, polyethylene, polyether sulfone, polycarbonate, polystyrene, and polyurethane flexible and rigid foams as possible reference materials for the University of San Francisco/NASA toxicity screening test method is discussed.

  2. Batch statistical process control of a fluid bed granulation process using in-line spatial filter velocimetry and product temperature measurements.

    PubMed

    Burggraeve, A; Van den Kerkhof, T; Hellings, M; Remon, J P; Vervaet, C; De Beer, T

    2011-04-18

    Fluid bed granulation is a batch process, which is characterized by the processing of raw materials for a predefined period of time, consisting of a fixed spraying phase and a subsequent drying period. The present study shows the multivariate statistical modeling and control of a fluid bed granulation process based on in-line particle size distribution (PSD) measurements (using spatial filter velocimetry) combined with continuous product temperature registration using a partial least squares (PLS) approach. Via the continuous in-line monitoring of the PSD and product temperature during granulation of various reference batches, a statistical batch model was developed allowing the real-time evaluation and acceptance or rejection of future batches. Continuously monitored PSD and product temperature process data of 10 reference batches (X-data) were used to develop a reference batch PLS model, regressing the X-data versus the batch process time (Y-data). Two PLS components captured 98.8% of the variation in the X-data block. Score control charts in which the average batch trajectory and upper and lower control limits are displayed were developed. Next, these control charts were used to monitor 4 new test batches in real-time and to immediately detect any deviations from the expected batch trajectory. By real-time evaluation of new batches using the developed control charts and by computation of contribution plots of deviating process behavior at a certain time point, batch losses or reprocessing can be prevented. Immediately after batch completion, all PSD and product temperature information (i.e., a batch progress fingerprint) was used to estimate some granule properties (density and flowability) at an early stage, which can improve batch release time. Individual PLS models relating the computed scores (X) of the reference PLS model (based on the 10 reference batches) and the density, respectively, flowabililty as Y-matrix, were developed. The scores of the 4 test batches were used to examine the predictive ability of the model. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. Graphic design and scientific research: the experience of the INGV Laboratorio Grafica e Immagini

    NASA Astrophysics Data System (ADS)

    Riposati, Daniela; D'Addezio, Giuliana; Chesi, Angela; Di Laura, Francesca; Palone, Sabrina

    2016-04-01

    The Laboratorio Grafica e Immagini is the INGV reference structure for the graphic and visual communication supporting institutional and research activities. Part of the activity is focused on the production of different materials concerning the INGV Educational and Outreach projects on the main themes of Geophysics and natural hazards. The forefront results of research activity, in fact, are periodically transferred to the public through an intense and comprehensive plan of scientific dissemination. In 10 years of activity, the Laboratorio has become an essential point of reference for this production, widely known within the scientific community. Positive experiences are the result of a strict relationship between graphic design and scientific research, in particular the process concerning the collaborative work between designers and researchers. In projects such as the realization of museum exhibition or the production of illustrative brochures, generally designed for broad-spectrum public, the goal is to make easier the understanding and to support the scientific message, making concepts enjoyable and fruitful through the emotional involvement that visual image can arouse. Our graphics and editorial products through composition of signs and images by using differt tools on different media (the use of colors, lettering, graphic design, visual design, web design etc.) link to create a strong identity "INGV style", in order to make them easily recognizable in Educational and Outreach projects: in one words "branding". For example, a project product package might include a logo or other artwork, organized text and pure design elements such as shapes and colour, which unify the piece. Colour is used not only to help the "brand" stand out from the international overview, but in our case to have a unifying outcome across all the INGV sections. We also analysed the restyling project of different materials, one of the most important features of graphic design, especially when using pre-existing product or diverse elements, including web elements.

  4. Improvement of radiology services based on the process management approach.

    PubMed

    Amaral, Creusa Sayuri Tahara; Rozenfeld, Henrique; Costa, Janaina Mascarenhas Hornos; Magon, Maria de Fátima de Andrade; Mascarenhas, Yvone Maria

    2011-06-01

    The health sector requires continuous investments to ensure the improvement of products and services from a technological standpoint, the use of new materials, equipment and tools, and the application of process management methods. Methods associated with the process management approach, such as the development of reference models of business processes, can provide significant innovations in the health sector and respond to the current market trend for modern management in this sector (Gunderman et al. (2008) [4]). This article proposes a process model for diagnostic medical X-ray imaging, from which it derives a primary reference model and describes how this information leads to gains in quality and improvements. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  5. 10 CFR 431.105 - Materials incorporated by reference.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Storage Tanks Test Procedures § 431.105 Materials incorporated by reference. (a) The Department... Water Supply Boilers, and Unfired Hot Water Storage Tanks,” Docket No. EE-RM/TP-99-480, Forrestal... 10 Energy 3 2012-01-01 2012-01-01 false Materials incorporated by reference. 431.105 Section 431...

  6. NBS/EPA (NATIONAL BUREAU OF STANDARDS/ENVIRONMENTAL PROTECTION AGENCY) CERTIFIED REFERENCE MATERIAL PERFORMANCE AUDIT PROGRAM: STATUS REPORT 1

    EPA Science Inventory

    A traceability procedure has been established which allows specialty gas producers to prepare gaseous pollutant Certified Reference Materials (CRMs). The accuracy, stability and homogeneity of the CRMs approach those of NBS Standard Reference Materials (SRMs). Part of this proced...

  7. NBS/EPA (NATIONAL BUREAU OF STANDARDS/ENVIRONMENTAL PROTECTION AGENCY) CERTIFIED REFERENCE MATERIAL PERFORMANCE AUDIT PROGRAM: STATUS REPORT 2

    EPA Science Inventory

    A traceability procedure has been established which allows specialty gas producers to prepare gaseous pollutant Certified Reference Materials (CRM's). The accuracy, stability and homogeneity of the CRM's approach those of NBS Standard Reference Materials (SRM's). As of October 19...

  8. Nicotine, acetanilide and urea multi-level 2H-, 13C- and 15N-abundance reference materials for continuous-flow isotope ratio mass spectrometry.

    PubMed

    Schimmelmann, Arndt; Albertino, Andrea; Sauer, Peter E; Qi, Haiping; Molinie, Roland; Mesnard, François

    2009-11-01

    Accurate determinations of stable isotope ratios require a calibration using at least two reference materials with different isotopic compositions to anchor the isotopic scale and compensate for differences in machine slope. Ideally, the delta values of these reference materials should bracket the isotopic range of samples with unknown delta values. While the practice of analyzing two isotopically distinct reference materials is common for water (VSMOW-SLAP) and carbonates (NBS 19 and L-SVEC), the lack of widely available organic reference materials with distinct isotopic composition has hindered the practice when analyzing organic materials by elemental analysis/isotope ratio mass spectrometry (EA-IRMS). At present only L-glutamic acids USGS40 and USGS41 satisfy these requirements for delta13C and delta15N, with the limitation that L-glutamic acid is not suitable for analysis by gas chromatography (GC). We describe the development and quality testing of (i) four nicotine laboratory reference materials for on-line (i.e. continuous flow) hydrogen reductive gas chromatography-isotope ratio mass-spectrometry (GC-IRMS), (ii) five nicotines for oxidative C, N gas chromatography-combustion-isotope ratio mass-spectrometry (GC-C-IRMS, or GC-IRMS), and (iii) also three acetanilide and three urea reference materials for on-line oxidative EA-IRMS for C and N. Isotopic off-line calibration against international stable isotope measurement standards at Indiana University adhered to the 'principle of identical treatment'. The new reference materials cover the following isotopic ranges: delta2H(nicotine) -162 to -45 per thousand, delta13C(nicotine) -30.05 to +7.72 per thousand, delta15N(nicotine) -6.03 to +33.62 per thousand; delta15N(acetanilide) +1.18 to +40.57 per thousand; delta13C(urea) -34.13 to +11.71 per thousand, delta15N(urea) +0.26 to +40.61 per thousand (recommended delta values refer to calibration with NBS 19, L-SVEC, IAEA-N-1, and IAEA-N-2). Nicotines fill a gap as the first organic nitrogen stable isotope reference materials for GC-IRMS that are available with different delta15N values. Comparative delta13C and delta15N on-line EA-IRMS data from 14 volunteering laboratories document the usefulness and reliability of acetanilides and ureas as EA-IRMS reference materials. Copyright 2009 John Wiley & Sons, Ltd.

  9. Baseline Assessment of 25-Hydroxyvitamin D Reference Material and Proficiency Testing/External Quality Assurance Material Commutability: A Vitamin D Standardization Program Study.

    PubMed

    Phinney, Karen W; Sempos, Christopher T; Tai, Susan S-C; Camara, Johanna E; Wise, Stephen A; Eckfeldt, John H; Hoofnagle, Andrew N; Carter, Graham D; Jones, Julia; Myers, Gary L; Durazo-Arvizu, Ramon; Miller, W Greg; Bachmann, Lorin M; Young, Ian S; Pettit, Juanita; Caldwell, Grahame; Liu, Andrew; Brooks, Stephen P J; Sarafin, Kurtis; Thamm, Michael; Mensink, Gert B M; Busch, Markus; Rabenberg, Martina; Cashman, Kevin D; Kiely, Mairead; Galvin, Karen; Zhang, Joy Y; Kinsella, Michael; Oh, Kyungwon; Lee, Sun-Wha; Jung, Chae L; Cox, Lorna; Goldberg, Gail; Guberg, Kate; Meadows, Sarah; Prentice, Ann; Tian, Lu; Brannon, Patsy M; Lucas, Robyn M; Crump, Peter M; Cavalier, Etienne; Merkel, Joyce; Betz, Joseph M

    2017-09-01

    The Vitamin D Standardization Program (VDSP) coordinated a study in 2012 to assess the commutability of reference materials and proficiency testing/external quality assurance materials for total 25-hydroxyvitamin D [25(OH)D] in human serum, the primary indicator of vitamin D status. A set of 50 single-donor serum samples as well as 17 reference and proficiency testing/external quality assessment materials were analyzed by participating laboratories that used either immunoassay or LC-MS methods for total 25(OH)D. The commutability test materials included National Institute of Standards and Technology Standard Reference Material 972a Vitamin D Metabolites in Human Serum as well as materials from the College of American Pathologists and the Vitamin D External Quality Assessment Scheme. Study protocols and data analysis procedures were in accordance with Clinical and Laboratory Standards Institute guidelines. The majority of the test materials were found to be commutable with the methods used in this commutability study. These results provide guidance for laboratories needing to choose appropriate reference materials and select proficiency or external quality assessment programs and will serve as a foundation for additional VDSP studies.

  10. Method for determining thermo-physical properties of specimens. [photographic recording of changes in thin film phase-change temperature indicating material in wind tunnel

    NASA Technical Reports Server (NTRS)

    Jones, R. A. (Inventor)

    1974-01-01

    The square root of the product of thermophysical properties q, c and k, where p is density, c is specific heat and k is thermal conductivity, is determined directly on a test specimen such as a wind tunnel model. The test specimen and a reference specimen of known specific heat are positioned at a given distance from a heat source. The specimens are provided with a coating, such as a phase change coating, to visually indicate that a given temperature was reached. A shutter interposed between the heat source and the specimens is opened and a motion picture camera is actuated to provide a time record of the heating step. The temperature of the reference specimen is recorded as a function of time. The heat rate to which both the test and reference specimens were subjected is determined from the temperature time response of the reference specimen by the conventional thin-skin calorimeter equation.

  11. Evaluation of droplet digital PCR for characterizing plasmid reference material used for quantifying ammonia oxidizers and denitrifiers.

    PubMed

    Dong, Lianhua; Meng, Ying; Wang, Jing; Liu, Yingying

    2014-02-01

    DNA reference materials of certified value have a critical function in many analytical processes of DNA measurement. Quantification of amoA genes in ammonia oxidizing bacteria (AOB) and archaea (AOA), and of nirS and nosZ genes in the denitrifiers is very important for determining their distribution and abundance in the natural environment. A plasmid reference material containing nirS, nosZ, amoA-AOB, and amoA-AOA is developed to provide a DNA standard with copy number concentration for ensuring comparability and reliability of quantification of these genes. Droplet digital PCR (ddPCR) was evaluated for characterization of the plasmid reference material. The result revealed that restriction endonuclease digestion of plasmids can improve amplification efficiency and minimize the measurement bias of ddPCR. Compared with the conformation of the plasmid, the size of the DNA fragment containing the target sequence and the location of the restriction site relative to the target sequence are not significant factors affecting plasmid quantification by ddPCR. Liquid chromatography-isotope dilution mass spectrometry (LC-IDMS) was used to provide independent data for quantifying the plasmid reference material. The copy number concentration of the digested plasmid determined by ddPCR agreed well with that determined by LC-IDMS, improving both the accuracy and reliability of the plasmid reference material. The reference value, with its expanded uncertainty (k = 2), of the plasmid reference material was determined to be (5.19 ± 0.41) × 10(9) copies μL(-1) by averaging the results of two independent measurements. Consideration of the factors revealed in this study can improve the reliability and accuracy of ddPCR; thus, this method has the potential to accurately quantify DNA reference materials.

  12. Matt waste from glass separated collection: an eco-sustainable addition for new building materials.

    PubMed

    Bignozzi, M C; Saccani, A; Sandrolini, F

    2009-01-01

    Matt waste (MW), a by-product of purification processes of cullet derived from separated glass waste collection, has been studied as filler for self-compacting concrete and as an addition for newly blended cement. Properties of self-compacting concrete compared to reference samples are reported. They include characteristics at the fresh and hardened states, and the compressive strength and porosity of mortar samples that were formulated with increasing amounts of MW to be used as cement replacement (up to 50wt.%). The effects of matt waste are discussed with respect to the mechanical and microstructural characteristics of the resulting new materials.

  13. Crystallization processes in pharmaceutical technology and drug delivery design

    NASA Astrophysics Data System (ADS)

    Shekunov, B. Yu; York, P.

    2000-04-01

    Crystallization is a major technological process for particle formation in pharmaceutical industry and, in addition, plays an important role in defining the stability and drug release properties of the final dosage forms. Industrial and regulatory aspects of crystallization are briefly reviewed with reference to solid-state properties of pharmaceuticals. Crystallization, incorporating wider definition to include precipitation and solid-state transitions, is considered in terms of preparation of materials for direct compression, formation of amorphous, solvated and polymorphic forms, chiral separation of drugs, production of materials for inhalation drug delivery and injections. Finally, recent developments in supercritical fluid particle technology is considered in relationship to the areas discussed.

  14. Progress toward the determination of correct classification rates in fire debris analysis.

    PubMed

    Waddell, Erin E; Song, Emma T; Rinke, Caitlin N; Williams, Mary R; Sigman, Michael E

    2013-07-01

    Principal components analysis (PCA), linear discriminant analysis (LDA), and quadratic discriminant analysis (QDA) were used to develop a multistep classification procedure for determining the presence of ignitable liquid residue in fire debris and assigning any ignitable liquid residue present into the classes defined under the American Society for Testing and Materials (ASTM) E 1618-10 standard method. A multistep classification procedure was tested by cross-validation based on model data sets comprised of the time-averaged mass spectra (also referred to as total ion spectra) of commercial ignitable liquids and pyrolysis products from common building materials and household furnishings (referred to simply as substrates). Fire debris samples from laboratory-scale and field test burns were also used to test the model. The optimal model's true-positive rate was 81.3% for cross-validation samples and 70.9% for fire debris samples. The false-positive rate was 9.9% for cross-validation samples and 8.9% for fire debris samples. © 2013 American Academy of Forensic Sciences.

  15. 49 CFR 572.30 - Incorporated materials.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 7 2011-10-01 2011-10-01 false Incorporated materials. 572.30 Section 572.30....30 Incorporated materials. (a) The drawings and specifications referred to in this regulation that... Federal Register has approved the materials incorporated by reference. For materials subject to change...

  16. 49 CFR 572.30 - Incorporated materials.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 7 2010-10-01 2010-10-01 false Incorporated materials. 572.30 Section 572.30....30 Incorporated materials. (a) The drawings and specifications referred to in this regulation that... Federal Register has approved the materials incorporated by reference. For materials subject to change...

  17. 49 CFR 572.30 - Incorporated materials.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 7 2012-10-01 2012-10-01 false Incorporated materials. 572.30 Section 572.30....30 Incorporated materials. (a) The drawings and specifications referred to in this regulation that... Federal Register has approved the materials incorporated by reference. For materials subject to change...

  18. 49 CFR 572.30 - Incorporated materials.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 7 2013-10-01 2013-10-01 false Incorporated materials. 572.30 Section 572.30....30 Incorporated materials. (a) The drawings and specifications referred to in this regulation that... Federal Register has approved the materials incorporated by reference. For materials subject to change...

  19. In-situ Production of High Density Polyethylene and Other Useful Materials on Mars

    NASA Technical Reports Server (NTRS)

    Flynn, Michael

    2005-01-01

    This paper describes a revolutionary materials structure and power storage concept based on the in-situ production of abiotic carbon 4 compounds. One of the largest single mass penalties required to support the human exploration of Mars is the surface habitat. This proposal will use physical chemical technologies to produce high density polyethylene (HDPE) inflatable structures and construction materials from Mars atmospheric CO2. The formation of polyethylene from Mars CO2 is based on the use of the Sabatier and modified Fischer Tropsch reactions. The proposed system will fully integrate with existing in-situ propellant production concepts. The technology will also be capable of supplementing human caloric requirements, providing solid and liquid fuels for energy storage, and providing significant reduction in mission risk. The NASA Mars Reference Mission Definition Team estimated that a conventional Mars surface habitat structure would weigh 10 tonnes. It is estimated that this technology could reduce this mass by 80%. This reduction in mass will significantly contribute to the reduction in total mission cost need to make a Mars mission a reality. In addition the potential reduction of risk provided by the ability to produce C4 and potentially higher carbon based materials in-situ on Mars is significant. Food, fuel, and shelter are only three of many requirements that would be impacted by this research.

  20. A microbial polyhydroxyalkanoates (PHA) based bio- and materials industry.

    PubMed

    Chen, Guo-Qiang

    2009-08-01

    Biopolyesters polyhydroxyalkanoates (PHA) produced by many bacteria have been investigated by microbiologists, molecular biologists, biochemists, chemical engineers, chemists, polymer experts and medical researchers. PHA applications as bioplastics, fine chemicals, implant biomaterials, medicines and biofuels have been developed and are covered in this critical review. Companies have been established or involved in PHA related R&D as well as large scale production. Recently, bacterial PHA synthesis has been found to be useful for improving robustness of industrial microorganisms and regulating bacterial metabolism, leading to yield improvement on some fermentation products. In addition, amphiphilic proteins related to PHA synthesis including PhaP, PhaZ or PhaC have been found to be useful for achieving protein purification and even specific drug targeting. It has become clear that PHA and its related technologies are forming an industrial value chain ranging from fermentation, materials, energy to medical fields (142 references).

  1. Feasibility of high-resolution continuum source molecular absorption spectrometry in flame and furnace for sulphur determination in petroleum products

    NASA Astrophysics Data System (ADS)

    Kowalewska, Zofia

    2011-07-01

    For the first time, high-resolution molecular absorption spectrometry with a high-intensity xenon lamp as radiation source has been applied for the determination of sulphur in crude oil and petroleum products. The samples were analysed as xylene solutions using vaporisation in acetylene-air flame or in an electrothermally heated graphite furnace. The sensitive rotational lines of the CS molecule, belonging to the ∆ν = 0 vibrational sequence within the electronic transition X 1∑ + → A 1П, were applied. For graphite furnace molecular absorption spectrometry, the Pd + Mg organic modifier was selected. Strong interactions with Pd atoms enable easier decomposition of sulphur-containing compounds, likely through the temporal formation of Pd xS y molecules. At the 258.056 nm line, with the wavelength range covering central pixel ± 5 pixels and with application of interactive background correction, the detection limit was 14 ng in graphite furnace molecular absorption spectrometry and 18 mg kg -1 in flame molecular absorption spectrometry. Meanwhile, application of 2-points background correction found a characteristic mass of 12 ng in graphite furnace molecular absorption spectrometry and a characteristic concentration of 104 mg kg -1 in flame molecular absorption spectrometry. The range of application of the proposed methods turned out to be significantly limited by the properties of the sulphur compounds of interest. In the case of volatile sulphur compounds, which can be present in light petroleum products, severe difficulties were encountered. On the contrary, heavy oils and residues from distillation as well as crude oil could be analysed using both flame and graphite furnace vaporisation. The good accuracy of the proposed methods for these samples was confirmed by their mutual consistency and the results from analysis of reference samples (certified reference materials and home reference materials with sulphur content determined by X-ray fluorescence spectrometry).

  2. Nuclear Forensic Inferences Using Iterative Multidimensional Statistics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robel, M; Kristo, M J; Heller, M A

    2009-06-09

    Nuclear forensics involves the analysis of interdicted nuclear material for specific material characteristics (referred to as 'signatures') that imply specific geographical locations, production processes, culprit intentions, etc. Predictive signatures rely on expert knowledge of physics, chemistry, and engineering to develop inferences from these material characteristics. Comparative signatures, on the other hand, rely on comparison of the material characteristics of the interdicted sample (the 'questioned sample' in FBI parlance) with those of a set of known samples. In the ideal case, the set of known samples would be a comprehensive nuclear forensics database, a database which does not currently exist. Inmore » fact, our ability to analyze interdicted samples and produce an extensive list of precise materials characteristics far exceeds our ability to interpret the results. Therefore, as we seek to develop the extensive databases necessary for nuclear forensics, we must also develop the methods necessary to produce the necessary inferences from comparison of our analytical results with these large, multidimensional sets of data. In the work reported here, we used a large, multidimensional dataset of results from quality control analyses of uranium ore concentrate (UOC, sometimes called 'yellowcake'). We have found that traditional multidimensional techniques, such as principal components analysis (PCA), are especially useful for understanding such datasets and drawing relevant conclusions. In particular, we have developed an iterative partial least squares-discriminant analysis (PLS-DA) procedure that has proven especially adept at identifying the production location of unknown UOC samples. By removing classes which fell far outside the initial decision boundary, and then rebuilding the PLS-DA model, we have consistently produced better and more definitive attributions than with a single pass classification approach. Performance of the iterative PLS-DA method compared favorably to that of classification and regression tree (CART) and k nearest neighbor (KNN) algorithms, with the best combination of accuracy and robustness, as tested by classifying samples measured independently in our laboratories against the vendor QC based reference set.« less

  3. An approach to shortening the timeframe between the emergence of new compounds on the drugs market and the availability of reference standards: The microscale syntheses of nitrazolam and clonazolam for use as reference materials, utilizing polymer-supported reagents.

    PubMed

    Dowling, Geraldine; Kavanagh, Pierce V; Eckhardt, Hans-Georg; Twamley, Brendan; Hessman, Gary; McLaughlin, Gavin; O'Brien, John; Brandt, Simon D

    2018-03-15

    Nitrazolam and clonazolam are 2 designer benzodiazepines available from Internet retailers. There is growing evidence suggesting that such compounds have the potential to cause severe adverse events. Information about tolerability in humans is scarce but typically, low doses can be difficult to administer for users when handling bulk material. Variability of the active ingredient in tablet formulations can also be of a concern. Customs, toxicology and forensic laboratories are increasingly encountering designer benzodiazepines, both in tablet and powdered form. The unavailability of reference standards can impact on the ability to identify these compounds. Therefore, the need arises for exploring in-house approaches to the preparation of new psychoactive substances (NPS) that can be carried out in a timely manner. The present study was triggered when samples of clonazolam were received in powdered and tablet form at a time when reference material for this drug was commercially unavailable. Therefore, microscale syntheses of clonazolam and its deschloro analog nitrazolam were developed utilizing polymer-supported reagents starting from 2-amino-2'-chloro-5-nitrobenzophenone (clonazolam) and 2-amino-5-nitrobenzophenone (nitrazolam). The final reaction step forming the 1,2,4-triazole ring moiety was performed within a gas chromatography-mass spectrometry (GC-MS) injector. A comparison with a preparative scale synthesis of both benzodiazepine derivatives showed that microscale synthesis might be an attractive option for a forensic laboratory in terms of time and cost savings when compared with traditional methods of synthesis and when qualitative identifications are needed to direct forensic casework. The reaction by-product profiles for both the micro and the preparative scale syntheses are also presented. Copyright © 2018 John Wiley & Sons, Ltd.

  4. Certified reference materials and reference methods for nuclear safeguards and security.

    PubMed

    Jakopič, R; Sturm, M; Kraiem, M; Richter, S; Aregbe, Y

    2013-11-01

    Confidence in comparability and reliability of measurement results in nuclear material and environmental sample analysis are established via certified reference materials (CRMs), reference measurements, and inter-laboratory comparisons (ILCs). Increased needs for quality control tools in proliferation resistance, environmental sample analysis, development of measurement capabilities over the years and progress in modern analytical techniques are the main reasons for the development of new reference materials and reference methods for nuclear safeguards and security. The Institute for Reference Materials and Measurements (IRMM) prepares and certifices large quantities of the so-called "large-sized dried" (LSD) spikes for accurate measurement of the uranium and plutonium content in dissolved nuclear fuel solutions by isotope dilution mass spectrometry (IDMS) and also develops particle reference materials applied for the detection of nuclear signatures in environmental samples. IRMM is currently replacing some of its exhausted stocks of CRMs with new ones whose specifications are up-to-date and tailored for the demands of modern analytical techniques. Some of the existing materials will be re-measured to improve the uncertainties associated with their certified values, and to enable laboratories to reduce their combined measurement uncertainty. Safeguards involve the quantitative verification by independent measurements so that no nuclear material is diverted from its intended peaceful use. Safeguards authorities pay particular attention to plutonium and the uranium isotope (235)U, indicating the so-called 'enrichment', in nuclear material and in environmental samples. In addition to the verification of the major ratios, n((235)U)/n((238)U) and n((240)Pu)/n((239)Pu), the minor ratios of the less abundant uranium and plutonium isotopes contain valuable information about the origin and the 'history' of material used for commercial or possibly clandestine purposes, and have therefore reached high level of attention for safeguards authorities. Furthermore, IRMM initiated and coordinated the development of a Modified Total Evaporation (MTE) technique for accurate abundance ratio measurements of the "minor" isotope-amount ratios of uranium and plutonium in nuclear material and, in combination with a multi-dynamic measurement technique and filament carburization, in environmental samples. Currently IRMM is engaged in a study on the development of plutonium reference materials for "age dating", i.e. determination of the time elapsed since the last separation of plutonium from its daughter nuclides. The decay of a radioactive parent isotope and the build-up of a corresponding amount of daughter nuclide serve as chronometer to calculate the age of a nuclear material. There are no such certified reference materials available yet. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Cellulose nanocrystals the next big nano-thing?

    NASA Astrophysics Data System (ADS)

    Postek, Michael T.; Vladar, Andras; Dagata, John; Farkas, Natalia; Ming, Bin; Sabo, Ronald; Wegner, Theodore H.; Beecher, James

    2008-08-01

    Biomass surrounds us from the smallest alga to the largest redwood tree. Even the largest trees owe their strength to a newly-appreciated class of nanomaterials known as cellulose nanocrystals (CNC). Cellulose, the world's most abundant natural, renewable, biodegradable polymer, occurs as whisker like microfibrils that are biosynthesized and deposited in plant material in a continuous fashion. Therefore, the basic raw materials for a future of new nanomaterials breakthroughs already abound in the environment and are available to be utilized in an array of future materials once the manufacturing processes and nanometrology are fully developed. This presentation will discuss some of the instrumentation, metrology and standards issues associated with nanomanufacturing of cellulose nanocrystals. The use of lignocellulosic fibers derived from sustainable, annually renewable resources as a reinforcing phase in polymeric matrix composites provides positive environmental benefits with respect to ultimate disposability and raw material use. Today we lack the essential metrology infrastructure that would enable the manufacture of nanotechnology-based products based on CNCs (or other new nanomaterial) to significantly impact the U.S. economy. The basic processes common to manufacturing - qualification of raw materials, continuous synthesis methods, process monitoring and control, in-line and off-line characterization of product for quality control purposes, validation by standard reference materials - are not generally in place for nanotechnology based products, and thus are barriers to innovation. One advantage presented by the study of CNCs is that, unlike other nanomaterials, at least, cellulose nanocrystal manufacturing is already a sustainable and viable bulk process. Literally tons of cellulose nanocrystals can be generated each day, producing other viable byproducts such as glucose (for alternative fuel) and gypsum (for buildings).There is an immediate need for the development of the basic manufacturing metrology infrastructure to implement fundamental best practices for manufacturing and in the determination of properties for these for nanoscale materials and the resultant products.

  6. Arctic audiology: trials, tribulations, and occasional successes.

    PubMed

    Ilecki, H J; Baxter, J D

    1981-08-01

    Efforts to provide audiologic services to the Inuit population of the Baffin Zone have frequently resulted in unexpected problems and frustrations. Often these are the product of two very different cultures coming together. This paper reviews the author's personal experiences in this regard with special reference to hearing aid attitudes, noise exposure, and the making of instructional audio-visual materials. A brief description of a recently revised hearing conservation program at Frobisher Bay is provided.

  7. Workforce Motivation in 1983: A Review for DoD Policy Implication.

    DTIC Science & Technology

    1983-12-01

    used: labor, management, money , machines, raw materials, etc. When productivity is expressed as output per man per hour, it is done only for...worker’s motivation than the combined strength of money , discipline, and even job security itself. Mayo’s prescription was to cultivate improved...realized an annual savings of $650,000 by application of the Skinnerian principles [Ref. 25]. 4. Need Hierarchy The most widely referred to motivation

  8. History of reference materials for food and nutrition metrology: As represented in the series of BERM Symposia

    USDA-ARS?s Scientific Manuscript database

    Establishment of a metrology-based measurement system requires the solid foundation of traceability of measurements to available, appropriate certified reference materials (CRM). In the early 1970s the first “biological” Reference Material (RM) of Bowens Kale, Orchard Leaves, and Bovine Liver from ...

  9. National Nutrition Education Clearing House Reference List, Secondary Teaching Materials and Teacher References.

    ERIC Educational Resources Information Center

    National Nutrition Education Clearing House, Berkeley, CA.

    A reference list of teaching materials and teacher guides in the field of nutrition is compiled in this pamphlet. Primary emphasis is on resources for secondary grades. The section on teaching materials includes books, pamphlets, leaflets, posters, charts, transparencies, ditto masters, kits, games, films, filmstrips, records, TV videotapes, and…

  10. Microbiological contamination in peanut confectionery processing plants.

    PubMed

    Carminati, J de A; Amorim Neto, D P; Morishita, K N; Takano, L V; Olivier Bernardi, A; Copetti, M V; do Nascimento, M da S

    2016-10-01

    In order to investigate Enterobacteriaceae, coliforms, Escherichia coli and Salmonella contamination, a survey was conducted at three peanut confectionery processing companies (A, B and C) in Brazil. Samples of different peanut confectionery products (n = 59), peanut raw material (n = 30), manufacturing environment (n = 116) and workers' hand surfaces (n = 12) were analysed. Salmonella and E. coli were not detected in any final product or raw material analysed. Enterobacteriaceae was isolated from 15% of final products. Coliforms were detected in only one sample. Referring to the raw material, six samples showed contamination by Enterobacteriaceae and three samples by coliforms. For the process environment, 19% and 11% of samples presented Enterobacteriaceae and coliforms. Escherichia coli was detected in 5% of samples, and one of these samples tested positive for Salmonella; this strain was serotyping as S. Heidelberg. All food handlers surveyed in Company C showed Enterobacteriaceae and coliforms on their hands. Escherichia coli was isolated from one food worker's hand. The results showed that the manufacturing environment, including food handlers were considered the main sources for possible contamination of peanut confectionery products. This has been the first study to investigate the occurrence of Salmonella and other Enterobacteriaceae throughout peanut confectionery processing lines. The results might be used to assist risk assessment studies and to establish more effective control measures. © 2016 The Society for Applied Microbiology.

  11. Olive Oil Based Emulsions in Frozen Puff Pastry Production

    NASA Astrophysics Data System (ADS)

    Gabriele, D.; Migliori, M.; Lupi, F. R.; de Cindio, B.

    2008-07-01

    Puff pastry is an interesting food product having different industrial applications. It is obtained by laminating layers of dough and fats, mainly shortenings or margarine, having specific properties which provides required spreading characteristic and able to retain moisture into dough. To obtain these characteristics, pastry shortenings are usually saturated fats, however the current trend in food industry is mainly oriented towards unsatured fats such as olive oil, which are thought to be safer for human health. In the present work, a new product, based on olive oil, was studied as shortening replacer in puff pastry production. To ensure the desired consistency, for the rheological matching between fat and dough, a water-in-oil emulsion was produced based on olive oil, emulsifier and a hydrophilic thickener agent able to increase material structure. Obtained materials were characterized by rheological dynamic tests in linear viscoelastic conditions, aiming to setup process and material consistency, and rheological data were analyzed by using the weak gel model. Results obtained for tested emulsions were compared to theological properties of a commercial margarine, adopted as reference value for texture and stability. Obtained emulsions are characterized by interesting rheological properties strongly dependent on emulsifier characteristics and water phase composition. However a change in process temperature during fat extrusion and dough lamination seems to be necessary to match properly typical dough rheological properties.

  12. Proactive interference effects on sentence production

    PubMed Central

    FERREIRA, VICTOR S.; FIRATO, CARLA E.

    2007-01-01

    Proactive interference refers to recall difficulties caused by prior similar memory-related processing. Information-processing approaches to sentence production predict that retrievability affects sentence form: Speakers may word sentences so that material that is difficult to retrieve is spoken later. In this experiment, speakers produced sentence structures that could include an optional that, thereby delaying the mention of a subsequent noun phrase. This subsequent noun phrase was either (1) conceptually similar to three previous noun phrases in the same sentence, leading to greater proactive interference, or (2) conceptually dissimilar, leading to less proactive interference. Speakers produced more thats (and were more disfluencies) before conceptually similar noun phrases, suggesting that retrieval difficulties during sentence production affect the syntactic structures of sentences that speakers produce. PMID:12613685

  13. Preparation of an in-house reference material containing fumonisins in Thai rice and matrix extension of the analytical method for Japanese rice.

    PubMed

    Awaludin, Norhafniza; Nagata, Reiko; Kawasaki, Tomomi; Kushiro, Masayo

    2009-12-01

    Mycotoxin contamination in rice is less reported, compared to that in wheat or maize, however, some Fusarium fungi occasionally infect rice in the paddy field. Fumonisins are mycotoxins mainly produced by Fusarium verticillioides, which often ruins maize. Rice adherent fungus Gibberella fujikuroi is taxonomically near to F. verticillioides, and there are sporadic reports of fumonisin contamination in rice from Asia, Europe and the United States. Therefore, there exists the potential risk of fumonisin contamination in rice as well as the need for the validated analytical method for fumonisins in rice. Although both natural and spiked reference materials are available for some Fusarium mycotoxins in matrices of wheat and maize, there are no reference materials for Fusarium mycotoxins in rice. In this study, we have developed a method for the preparation of a reference material containing fumonisins in Thai rice. A ShakeMaster grinding machine was used for the preparation of a mixed material of blank Thai rice and F. verticillioides-infected Thai rice. The homogeneity of the mixed material was confirmed by one-way analysis of variance, which led this material to serve as an in-house reference material. Using this reference material, several procedures to extract fumonisins from Thai rice were compared. Accordingly, we proved the applicability of an effective extraction procedure for the determination of fumonisins in Japanese rice.

  14. Preparation of an In-House Reference Material Containing Fumonisins in Thai Rice and Matrix Extension of the Analytical Method for Japanese Rice

    PubMed Central

    Awaludin, Norhafniza; Nagata, Reiko; Kawasaki, Tomomi; Kushiro, Masayo

    2009-01-01

    Mycotoxin contamination in rice is less reported, compared to that in wheat or maize, however, some Fusarium fungi occasionally infect rice in the paddy field. Fumonisins are mycotoxins mainly produced by Fusarium verticillioides, which often ruins maize. Rice adherent fungus Gibberella fujikuroi is taxonomically near to F. verticillioides, and there are sporadic reports of fumonisin contamination in rice from Asia, Europe and the United States. Therefore, there exists the potential risk of fumonisin contamination in rice as well as the need for the validated analytical method for fumonisins in rice. Although both natural and spiked reference materials are available for some Fusarium mycotoxins in matrices of wheat and maize, there are no reference materials for Fusarium mycotoxins in rice. In this study, we have developed a method for the preparation of a reference material containing fumonisins in Thai rice. A ShakeMaster grinding machine was used for the preparation of a mixed material of blank Thai rice and F. verticillioides-infected Thai rice. The homogeneity of the mixed material was confirmed by one-way analysis of variance, which led this material to serve as an in-house reference material. Using this reference material, several procedures to extract fumonisins from Thai rice were compared. Accordingly, we proved the applicability of an effective extraction procedure for the determination of fumonisins in Japanese rice. PMID:22069540

  15. 49 CFR 193.2013 - Incorporation by reference.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY LIQUEFIED NATURAL... incorporated materials are available for inspection in the Pipeline and Hazardous Materials Safety... referenced material 49 CFR Reference A. American Gas Association (AGA): (1) “Purging Principles and Practices...

  16. A new thorium-229 reference material

    DOE PAGES

    Essex, Richard M.; Mann, Jaqueline L.; Williams, Ross W.; ...

    2017-07-27

    A new reference material was characterized for 229Th molality and thorium isotope amount ratios. This reference material is intended for use in nuclear forensic analyses as an isotope dilution mass spectrometry spike. The reference material value and expanded uncertainty (k = 2) for the 229Th molality is (1.1498 ± 0.0016)×10 -10 mol g -1 solution. The value and expanded uncertainty (k = 2) for the n( 230Th)/n( 229Th) ratio is (5.18 ± 0.26)×10 -5 and the n( 232Th)/n( 229Th) ratio is (3.815 ± 0.092)×10 -4.

  17. A new thorium-229 reference material

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Essex, Richard M.; Mann, Jaqueline L.; Williams, Ross W.

    A new reference material was characterized for 229Th molality and thorium isotope amount ratios. This reference material is intended for use in nuclear forensic analyses as an isotope dilution mass spectrometry spike. The reference material value and expanded uncertainty (k = 2) for the 229Th molality is (1.1498 ± 0.0016)×10 -10 mol g -1 solution. The value and expanded uncertainty (k = 2) for the n( 230Th)/n( 229Th) ratio is (5.18 ± 0.26)×10 -5 and the n( 232Th)/n( 229Th) ratio is (3.815 ± 0.092)×10 -4.

  18. Electronic cigarettes: product characterisation and design considerations.

    PubMed

    Brown, Christopher J; Cheng, James M

    2014-05-01

    To review the available evidence regarding electronic cigarette (e-cigarette) product characterisation and design features in order to understand their potential impact on individual users and on public health. Systematic literature searches in 10 reference databases were conducted through October 2013. A total of 14 articles and documents and 16 patents were included in this analysis. Numerous disposable and reusable e-cigarette product options exist, representing wide variation in product configuration and component functionality. Common e-cigarette components include an aerosol generator, a flow sensor, a battery and a nicotine-containing solution storage area. e-cigarettes currently include many interchangeable parts, enabling users to modify the character of the delivered aerosol and, therefore, the product's 'effectiveness' as a nicotine delivery product. Materials in e-cigarettes may include metals, rubber and ceramics. Some materials may be aerosolised and have adverse health effects. Several studies have described significant performance variability across and within e-cigarette brands. Patent applications include novel product features designed to influence aerosol properties and e-cigarette efficiency at delivering nicotine. Although e-cigarettes share a basic design, engineering variations and user modifications result in differences in nicotine delivery and potential product risks. e-cigarette aerosols may include harmful and potentially harmful constituents. Battery explosions and the risks of exposure to the e-liquid (especially for children) are also concerns. Additional research will enhance the current understanding of basic e-cigarette design and operation, aerosol production and processing, and functionality. A standardised e-cigarette testing regime should be developed to allow product comparisons.

  19. 15 CFR 200.104 - Standard reference materials.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... the NIST National Measurement Laboratory administers a program to provide many types of well... be readily referred to a common base. NIST SP 260 is a catalog of Standard Reference Materials available from NIST. ...

  20. 15 CFR 200.104 - Standard reference materials.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... the NIST National Measurement Laboratory administers a program to provide many types of well... be readily referred to a common base. NIST SP 260 is a catalog of Standard Reference Materials available from NIST. ...

  1. 15 CFR 200.104 - Standard reference materials.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... the NIST National Measurement Laboratory administers a program to provide many types of well... be readily referred to a common base. NIST SP 260 is a catalog of Standard Reference Materials available from NIST. ...

  2. 15 CFR 200.104 - Standard reference materials.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... the NIST National Measurement Laboratory administers a program to provide many types of well... be readily referred to a common base. NIST SP 260 is a catalog of Standard Reference Materials available from NIST. ...

  3. 15 CFR 200.104 - Standard reference materials.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... the NIST National Measurement Laboratory administers a program to provide many types of well... be readily referred to a common base. NIST SP 260 is a catalog of Standard Reference Materials available from NIST. ...

  4. Requirements for the Development of Bacillus Anthracis Spore Reference Materials Used to Test Detection Systems

    PubMed Central

    Almeida, Jamie L.; Wang, Lili; Morrow, Jayne B.; Cole, Kenneth D.

    2006-01-01

    Bacillus anthracis spores have been used as biological weapons and the possibility of their further use requires surveillance systems that can accurately and reliably detect their presence in the environment. These systems must collect samples from a variety of matrices, process the samples, and detect the spores. The processing of the sample may include removal of inhibitors, concentration of the target, and extraction of the target in a form suitable for detection. Suitable reference materials will allow the testing of each of these steps to determine the sensitivity and specificity of the detection systems. The development of uniform and well-characterized reference materials will allow the comparison of different devices and technologies as well as assure the continued performance of detection systems. This paper discusses the special requirements of reference materials for Bacillus anthracis spores that could be used for testing detection systems. The detection of Bacillus anthracis spores is based on recognition of specific characteristics (markers) on either the spore surface or in the nucleic acids (DNA). We have reviewed the specific markers and their relevance to characterization of reference materials. We have also included the approach for the characterization of candidate reference materials that we are developing at the NIST laboratories. Additional applications of spore reference materials would include testing sporicidal treatments, techniques for sampling the environment, and remediation of spore-contaminated environments. PMID:27274929

  5. Isolation and Characterization of Lytic Properties of Bacteriophages Specific for M. haemolytica Strains.

    PubMed

    Urban-Chmiel, Renata; Wernicki, Andrzej; Stęgierska, Diana; Dec, Marta; Dudzic, Anna; Puchalski, Andrzej

    2015-01-01

    The objective of this study was isolation and morphological characterization of temperate bacteriophages obtained from M. haemolytica strains and evaluation of their lytic properties in vitro against M. haemolytica isolated from the respiratory tract of calves. The material for the study consisted of the reference strain M. haemolytica serotype 1 (ATCC®) BAA-410™, reference serotypes A1, A2, A5, A6, A7, A9 and A11, and wild-type isolates of M. haemolytica. Bacteriophages were induced from an overnight bacterial starter culture of all examined M. haemolytica strains treated with mitomycin C. The lytic properties and host ranges were determined by plaque assays. The morphology of the bacteriophages was examined in negative-stained smears with 5% uranyl acetate solution using a transmission electron microscope. The genetic analysis of the bacteriophages was followed by restriction analysis of bacteriophage DNA. This was followed by analysis of genetic material by polymerase chain reaction (PCR). Eight bacteriophages were obtained, like typical of the families Myoviridae, Siphoviridae and Podoviridae. Most of the bacteriophages exhibited lytic properties against the M. haemolytica strains. Restriction analysis revealed similarities to the P2-like phage obtained from the strain M. haemolytica BAA-410. The most similar profiles were observed in the case of bacteriophages φA1 and φA5. All of the bacteriophages obtained were characterized by the presence of additional fragments in the restriction profiles with respect to the P2-like reference phage. In the analysis of PCR products for the P2-like reference phage phi-MhaA1-PHL101 (DQ426904) and the phages of the M. haemolytica serotypes, a 734-bp phage PCR product was obtained. The primers were programmed in Primer-Blast software using the structure of the sequence DQ426904 of reference phage PHL101. The results obtained indicate the need for further research aimed at isolating and characterizing bacteriophages, including sequence analysis of selected fragments. Moreover, standardization of methods for obtaining them in order to eliminate M. haemolytica bacteria involved in the etiopathogenesis of BRDC is essential.

  6. Quality Management and Calibration

    NASA Astrophysics Data System (ADS)

    Merkus, Henk G.

    Good specification of a product’s performance requires adequate characterization of relevant properties. Particulate products are usually characterized by some PSD, shape or porosity parameter(s). For proper characterization, adequate sampling, dispersion, and measurement procedures should be available or developed and skilful personnel should use appropriate, well-calibrated/qualified equipment. The characterization should be executed, in agreement with customers, in a wellorganized laboratory. All related aspects should be laid down in a quality handbook. The laboratory should provide proof for its capability to perform the characterization of stated products and/or reference materials within stated confidence limits. This can be done either by internal validation and audits or by external GLP accreditation.

  7. Sludge stabilization through aerobic digestion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hartman, R.B.; Smith, D.G.; Bennett, E.R.

    1979-10-01

    The aerobic digestion process with certain modifications is evaluated as an alternative for sludge processing capable of developing a product with characteristics required for land application. Environmental conditions, including temperature, solids concentration, and digestion time, that affect the aerobic digestion of a mixed primary sludge-trickling filter humus are investigated. Variations in these parameters that influence the characteristics of digested sludge are determined, and the parameters are optimized to: provide the maximum rate of volatile solids reduction; develop a stable, nonodorous product sludge; and provide the maximum rate of oxidation of the nitrogenous material present in the feed sludge. (3 diagrams,more » 9 graphs, 15 references, 3 tables)« less

  8. [Construction of NIRS-based total quality control system for compound Ejiao oral liquid and relative thinking].

    PubMed

    Zhang, Yan; Zhang, Lu; Tian, Shou-Sheng; Zhou, Xiang-Shan; Li, Wen-Long; Qu, Hai-Bin

    2016-10-01

    In this paper, near infrared spectroscopy (NIRS)-based total quality control system of compound Ejiao oral liquid is introduced briefly, including the quality control of raw traditional Chinese medicine (TCM) materials, monitoring and control of the extract and the alkaline precipitation technics, and also the inspection of finished products in both open bottle and non-opening modes. By analyzing and summing up the significance and difficulties, several important problems in the practical applications of NIRS technology are proposed, which will provide references for the similar studies of other TCM products. Copyright© by the Chinese Pharmaceutical Association.

  9. Evaluation of measurement uncertainty for purity of a monoterpenic acid by small-scale coulometry

    NASA Astrophysics Data System (ADS)

    Norte, L. C.; de Carvalho, E. M.; Tappin, M. R. R.; Borges, P. P.

    2018-03-01

    Purity of the perylic acid (HPe) which is a monoterpenic acid from natural product (NP) with anti-inflammatory and anticancer properties was analyzed by small-scale coulometry (SSC), due to the low availability of HPe on the pharmaceutic market and its high cost. This work aims to present the evaluation of the measurements uncertainty from the purity of HPe by using SSC. Coulometric mean of purity obtained from 5 replicates resulted in 94.23% ± 0.88% (k = 2.06, for an approximately 95% confidence level). These studies aim in the future to develop the production of certified reference materials from NPs.

  10. Accelerated design of bioconversion processes using automated microscale processing techniques.

    PubMed

    Lye, Gary J; Ayazi-Shamlou, Parviz; Baganz, Frank; Dalby, Paul A; Woodley, John M

    2003-01-01

    Microscale processing techniques are rapidly emerging as a means to increase the speed of bioprocess design and reduce material requirements. Automation of these techniques can reduce labour intensity and enable a wider range of process variables to be examined. This article examines recent research on various individual microscale unit operations including microbial fermentation, bioconversion and product recovery techniques. It also explores the potential of automated whole process sequences operated in microwell formats. The power of the whole process approach is illustrated by reference to a particular bioconversion, namely the Baeyer-Villiger oxidation of bicyclo[3.2.0]hept-2-en-6-one for the production of optically pure lactones.

  11. River sediment (S-37)--a new analytical quality control material ensuring comparability of chlorinated hydrocarbon analysis during an international environmental study in China.

    PubMed

    Gawlik, B M; Martens, D; Henkelmann, B; Schramm, K W; Kettrup, A; Muntau, H

    2000-06-01

    A sediment reference material (S-37) was prepared as analytical quality control material to be used within an international project on polychlorinated hydrocarbon analysis in two Chinese rivers. The raw material was sampled during a cruise on Yangtse River and transported afterwards to the JRC Ispra for further processing. The material was treated according to the general principles applicable for candidate reference material production. After a thorough homogeneity study of the bulk the material was bottled. A total of 1,080 bottles each containing 50 g of dry sediment powder was obtained. Final homogeneity and stability testing proved the material to be fit for the purpose. Isotope dilution GC/MS was used to establish target values for pentachlorobenzene (1.17 +/- 0.08 ng/g), hexachlorobenzene (3.60 +/- 0.17 ng/g), octachlorostyrene (0.19 +/- 0.01 ng/g), pentachloroanisole (0.52 +/- 0.02 ng/g), alpha-HCH (0.70 +/- 0.05 ng/g), beta-HCH (1.38 +/- 0.18 ng/g), gamma-HCH (0.83 +/- 038 ng/g), 2,4'-DDT (0.36 +/- 0.04 ng/g), 2,4'-DDE (0.29 +/- 0.02 ng/g), 2,4'-DDD (0.49 +/- 0.02), 4,4'-DDT (3.42 +/- 0.47 ng/g), 4,4'-DDD (1.29 +/- 0.17 ng/g), PCB 28 (0.11 +/- 0.01 ng/g), PCB 52 (0.09 +/- 0.003 ng/g), PCB 101 (0.07 +/- 0.003 ng/g), PCB 138 (0.06 +/- 0.003 ng/g) and PCB 153 (0.06 +/- 0.003 ng/g). Furthermore, indicative values for major and minor constituents as well as for polychlorinated dibenzodioxines and -furanes were measured.

  12. Investigation of the performance behavior of a forward osmosis membrane system using various feed spacer materials fabricated by 3D printing technique.

    PubMed

    Yanar, Numan; Son, Moon; Yang, Eunmok; Kim, Yeji; Park, Hosik; Nam, Seung-Eun; Choi, Heechul

    2018-07-01

    Recently, feed spacer research for improving the performance of a membrane module has adopted three-dimensional (3D) printing technology. This study aims to improve the performance of membrane feed spacers by using various materials and incorporating 3D printing. The samples were fabricated after modeling with 3D computer-aided design (CAD) software to investigate the mechanical strength, water flux, reverse solute flux, and fouling performances. This research was performed using acrylonitrile butadiene styrene (ABS), polypropylene (PP), and natural polylactic acid (PLA) as printing material, and the spacer model was produced using a diamond-shaped feed spacer, with a commercially available product as a reference. The 3D printed samples were initially compared in terms of size and precision with the 3D CAD model, and deviations were observed between the products and the CAD model. Then, the spacers were tested in terms of mechanical strength, water flux, reverse solute flux, and fouling (alginate-based waste water was used as a model foulant). Although there was not much difference among the samples regarding the water flux, better performances than the commercial product were obtained for reverse solute flux and fouling resistance. When comparing the prominent performance of natural PLA with the commercial product, PLA was found to have approximately 10% less fouling (based on foulant volume per unit area and root mean square roughness values), although it showed similar water flux. Thus, another approach has been introduced for using bio-degradable materials for membrane spacers. Copyright © 2018 Elsevier Ltd. All rights reserved.

  13. Rheological and molecular weight comparisons of approved hyaluronic acid products - preliminary standards for establishing class III medical device equivalence.

    PubMed

    Braithwaite, Gavin J C; Daley, Michael J; Toledo-Velasquez, David

    2016-01-01

    Hyaluronic acid of various molecular weights has been in use for the treatment of osteoarthritis knee pain for decades. Worldwide, these products are regulated as either as drugs or devices and in some countries as both. In the US, this class of products is regulated as Class III medical devices, which places specific regulatory requirements on developers of these materials under a Pre-Market Approval process, typically requiring data from prospective randomized controlled clinical studies. In 1984 pharmaceutical manufacturers became able to file an Abbreviated New Drug Application for approval of a generic drug, thus establishing standards for demonstrating equivalence to an existing chemical entity. Recently, the first biosimilar, or 'generic biologic', was approved. Biosimilars are biological products that are approved by the FDA because they are 'highly similar' to a reference product, and have been shown to have no clinically meaningful differences from the reference product. For devices, Class II medical devices have a pathway for declaring equivalence to an existing product by filing a 510 k application for FDA clearance. However, until recently no equivalent regulatory pathway was available to Class III devices. In this paper, we consider the critical mechanical performance parameters for intra-articular hyaluronic products to demonstrate indistinguishable characteristics. Analogous to the aforementioned pathways that allow for a demonstration of equivalence, we examine these parameters for an existing, marketed device and compare molecular weight and rheological properties of multiple batches of a similar product. We propose that this establishes a scientific rationale for establishing Class III medical device equivalence.

  14. Recent progress in the growth and applications of graphene as a smart material: A review

    NASA Astrophysics Data System (ADS)

    Aissa, Brahim; Memon, Nasir; Ali, Adnan; Khraisheh, Marwan

    2015-09-01

    Innovative breakthroughs in fundamental research and industrial applications of graphene material have made its mass and low-cost production a necessary step toward its real world applications. This one-atom thick crystal of carbon, gathers a set of unique physico-chemical properties, ranging from its extreme mechanical behavior to its exceptional electrical and thermal conductivities, which are making graphene as a serious alternative to replace many conventional materials for various applications. In this review paper, we highlight the most important experimental results on the synthesis of graphene material, its emerging properties with reference to its smart applications. We discuss the possibility to successfully integrating graphene directly into device, enabling thereby the realization of a wide range of applications, including actuation, photovoltaic, thermoelectricity, shape memory, self-healing, electrorheology and space missions. The future outlook of graphene is also considered and discussed.

  15. Thermal shock tests to qualify different tungsten grades as plasma facing material

    NASA Astrophysics Data System (ADS)

    Wirtz, M.; Linke, J.; Loewenhoff, Th; Pintsuk, G.; Uytdenhouwen, I.

    2016-02-01

    The electron beam device JUDITH 1 was used to establish a testing procedure for the qualification of tungsten as plasma facing material. Absorbed power densities of 0.19 and 0.38 GW m-2 for an edge localized mode-like pulse duration of 1 ms were chosen. Furthermore, base temperatures of room temperature, 400 °C and 1000 °C allow investigating the thermal shock performance in the brittle, ductile and high temperature regime. Finally, applying 100 pulses under all mentioned conditions helps qualifying the general damage behaviour while with 1000 pulses for the higher power density the influence of thermal fatigue is addressed. The investigated reference material is a tungsten product produced according to the ITER material specifications. The obtained results provide a general overview of the damage behaviour with quantified damage characteristics and thresholds. In particular, it is shown that the damage strongly depends on the microstructure and related thermo-mechanical properties.

  16. Polyhydroxybutyrate accumulation by a Serratia sp.

    PubMed

    Lugg, Harriet; Sammons, Rachel L; Marquis, Peter M; Hewitt, Christopher J; Yong, Ping; Paterson-Beedle, Marion; Redwood, Mark D; Stamboulis, Artemis; Kashani, Mitra; Jenkins, Mike; Macaskie, Lynne E

    2008-03-01

    A strain of Serratia sp. showed intracellular electron-transparent inclusion bodies when incubated in the presence of citrate and glycerol 2-phosphate without nitrogen source following pre-growth under carbon-limitation in continuous culture. About 1.3 mmol citrate were consumed per 450 mg biomass, giving a calculated yield of maximally 55% of stored material per g of biomass dry wt. The inclusion bodies were stained with Sudan Black and Nile Red (NR), suggesting a lipid material, which was confirmed as polyhydroxybutyrate (PHB) by analysis of molecular fragments by GC and by FTIR spectroscopy of isolated bio-PHB in comparison with reference material. Multi-parameter flow cytometry in conjunction with NR fluorescence, and electron microscopy, showed that not all cells contained heavy PHB bodies, suggesting the potential for increasing the overall yield. The economic attractiveness is enhanced by the co-production of nanoscale hydroxyapatite (HA), a possible high-value precursor for bone replacement materials.

  17. Natural supramolecular building blocks: from virus coat proteins to viral nanoparticles.

    PubMed

    Liu, Zhi; Qiao, Jing; Niu, Zhongwei; Wang, Qian

    2012-09-21

    Viruses belong to a fascinating class of natural supramolecular structures, composed of multiple copies of coat proteins (CPs) that assemble into different shapes with a variety of sizes from tens to hundreds of nanometres. Because of their advantages including simple/economic production, well-defined structural features, unique shapes and sizes, genetic programmability and robust chemistries, recently viruses and virus-like nanoparticles (VLPs) have been used widely in biomedical applications and materials synthesis. In this critical review, we highlight recent advances in the use of virus coat proteins (VCPs) and viral nanoparticles (VNPs) as building blocks in self-assembly studies and materials development. We first discuss the self-assembly of VCPs into VLPs, which can efficiently incorporate a variety of different materials as cores inside the viral protein shells. Then, the self-assembly of VNPs at surfaces or interfaces is summarized. Finally, we discuss the co-assembly of VNPs with different functional materials (178 references).

  18. Analysis of the physicochemical properties of post-manufacturing waste derived from production of methyl esters from rapeseed oil

    NASA Astrophysics Data System (ADS)

    Kachel-Jakubowska, Magdalena; Matwijczuk, Arkadiusz; Gagoś, Mariusz

    2017-04-01

    The technology of transesterification of biodiesel obtained from many agricultural products, which are often referred to as renewable resources, yields substantial amounts of by-products. They exhibit various properties that prompt scientific research into potential application thereof. Various spectroscopic methods, e.g. Fourier transform infrared spectroscopy, are being increasingly used in the research. In this paper, we present the results of Fourier transform infrared spectroscopy spectroscopy analyses of technical glycerine, distilled glycerine, and matter organic non glycerol, i.e. by-products of biodiesel production. To facilitate the spectroscopic analysis, a number of parameters were determined for all the materials, e.g. the calorific value, water content, sulphated ash content, methanol content, acidity, as well as the contents of esters, heavy metals, aldehydes, nitrogen, and phosphorus. The results indicate that the analysed products are characterised by a comparable calorific value in the range from 11.35 to 16.05 MJ kg-1 in the case of matter organic non glycerol and technical glycerine. Observation of changes in the position of selected peaks in the range of 3700-650 cm-1 in the Fourier transform infrared spectroscopy method facilitates determination of the level of degradation of the analysed material. Changes in the wavelength ranges can be used for monitoring the formation of secondary oxidation products containing carbonyl groups.

  19. [Analysis of productivity, quality and cost of first grade laboratories: blood biometry].

    PubMed

    Avila, L; Hernández, P; Cruz, A; Zurita, B; Terres, A M; Cruz, C

    1999-04-01

    Assessment of productivity, quality and production costs and determination of the efficiency of top grade clinical laboratories in Mexico. Ten laboratories were selected from among the total number (52) existing in Mexico City, and the Donabedian model of structure, process and results were applied. Blood count was selected as a tracer. The principal problems found were: inadequate distribution of trained human resources, poor glass material, inadequate analytic process and low productivity. These factors are reflected in the unit costs, which exceed reference laboratory costs by 200%. Only 50% of the laboratories analyzed generate reliable results. Only 20% of the laboratories studied operate efficiently. To solve the problems identified requires integral strategies at different levels. A specific recomendation for the improvement of quality and productivity is an assessment of the cost/benefit of creating a central laboratory and using the remaining sites exclusively for the collection of samples.

  20. Reference materials for cellular therapeutics.

    PubMed

    Bravery, Christopher A; French, Anna

    2014-09-01

    The development of cellular therapeutics (CTP) takes place over many years, and, where successful, the developer will anticipate the product to be in clinical use for decades. Successful demonstration of manufacturing and quality consistency is dependent on the use of complex analytical methods; thus, the risk of process and method drift over time is high. The use of reference materials (RM) is an established scientific principle and as such also a regulatory requirement. The various uses of RM in the context of CTP manufacturing and quality are discussed, along with why they are needed for living cell products and the analytical methods applied to them. Relatively few consensus RM exist that are suitable for even common methods used by CTP developers, such as flow cytometry. Others have also identified this need and made proposals; however, great care will be needed to ensure any consensus RM that result are fit for purpose. Such consensus RM probably will need to be applied to specific standardized methods, and the idea that a single RM can have wide applicability is challenged. Written standards, including standardized methods, together with appropriate measurement RM are probably the most appropriate way to define specific starting cell types. The characteristics of a specific CTP will to some degree deviate from those of the starting cells; consequently, a product RM remains the best solution where feasible. Each CTP developer must consider how and what types of RM should be used to ensure the reliability of their own analytical measurements. Copyright © 2014 International Society for Cellular Therapy. Published by Elsevier Inc. All rights reserved.

  1. DNA barcoding detects contamination and substitution in North American herbal products

    PubMed Central

    2013-01-01

    Background Herbal products available to consumers in the marketplace may be contaminated or substituted with alternative plant species and fillers that are not listed on the labels. According to the World Health Organization, the adulteration of herbal products is a threat to consumer safety. Our research aimed to investigate herbal product integrity and authenticity with the goal of protecting consumers from health risks associated with product substitution and contamination. Methods We used DNA barcoding to conduct a blind test of the authenticity for (i) 44 herbal products representing 12 companies and 30 different species of herbs, and (ii) 50 leaf samples collected from 42 herbal species. Our laboratory also assembled the first standard reference material (SRM) herbal barcode library from 100 herbal species of known provenance that were used to identify the unknown herbal products and leaf samples. Results We recovered DNA barcodes from most herbal products (91%) and all leaf samples (100%), with 95% species resolution using a tiered approach (rbcL + ITS2). Most (59%) of the products tested contained DNA barcodes from plant species not listed on the labels. Although we were able to authenticate almost half (48%) of the products, one-third of these also contained contaminants and or fillers not listed on the label. Product substitution occurred in 30/44 of the products tested and only 2/12 companies had products without any substitution, contamination or fillers. Some of the contaminants we found pose serious health risks to consumers. Conclusions Most of the herbal products tested were of poor quality, including considerable product substitution, contamination and use of fillers. These activities dilute the effectiveness of otherwise useful remedies, lowering the perceived value of all related products because of a lack of consumer confidence in them. We suggest that the herbal industry should embrace DNA barcoding for authenticating herbal products through testing of raw materials used in manufacturing products. The use of an SRM DNA herbal barcode library for testing bulk materials could provide a method for 'best practices? in the manufacturing of herbal products. This would provide consumers with safe, high quality herbal products. PMID:24120035

  2. An approach to quality and security of supply for single-use bioreactors.

    PubMed

    Barbaroux, Magali; Gerighausen, Susanne; Hackel, Heiko

    2014-01-01

    Single-use systems (also referred to as disposables) have become a huge part of the bioprocessing industry, which raised concern in the industry regarding quality and security of supply. Processes must be in place to assure the supply and control of outsourced activities and quality of purchased materials along the product life cycle. Quality and security of supply for single-use bioreactors (SUBs) are based on a multidisciplinary approach. Developing a state-of-the-art SUB-system based on quality by design (QbD) principles requires broad expertise and know-how including the cell culture application, polymer chemistry, regulatory requirements, and a deep understanding of the biopharmaceutical industry. Using standardized products reduces the complexity and strengthens the robustness of the supply chain. Well-established supplier relations including risk mitigation strategies are the basis for achieving long-term security of supply. Well-developed quality systems including change control approaches aligned with the requirements of the biopharmaceutical industry are a key factor in supporting long-term product availability. This chapter outlines the approach to security of supply for key materials used in single-use production processes for biopharmaceuticals from a supplier perspective.

  3. Identification of Eight Synthetic Cannabinoids, Including 5F-AKB48 in Seized Herbal Products Using DART-TOF-MS and LC-QTOF-MS as Nontargeted Screening Methods.

    PubMed

    Moore, Katherine N; Garvin, Demetra; Thomas, Brian F; Grabenauer, Megan

    2017-09-01

    Synthetic cannabinoids are sprayed onto plant material and smoked for their marijuana-like effects. Clandestine manufacturers modify synthetic cannabinoid structures by creating closely related analogs. Forensic laboratories are tasked with detection of these analog compounds, but targeted analytical methods are often thwarted by the structural modifications. Here, direct analysis in real time coupled to accurate mass time-of-flight mass spectrometry (DART-TOF-MS) in combination with liquid chromatography quadruple time-of-flight mass spectrometry (LC-QTOF-MS) are presented as a screening and nontargeted confirmation method, respectively. Methanol extracts of herbal material were run using both methods. Spectral data from four different herbal products were evaluated by comparing fragmentation pattern, accurate mass and retention time to available reference standards. JWH-018, JWH-019, AM2201, JWH-122, 5F-AKB48, AKB48-N-(4-pentenyl) analog, UR144, and XLR11 were identified in the products. Results demonstrate that DART-TOF-MS affords a useful approach for rapid screening of herbal products for the presence and identification of synthetic cannabinoids. © 2017 American Academy of Forensic Sciences.

  4. Applying high-resolution melting (HRM) technology to identify five commonly used Artemisia species.

    PubMed

    Song, Ming; Li, Jingjian; Xiong, Chao; Liu, Hexia; Liang, Junsong

    2016-10-04

    Many members of the genus Artemisia are important for medicinal purposes with multiple pharmacological properties. Often, these herbal plants sold on the markets are in processed forms so it is difficult to authenticate. Routine testing and identification of these herbal materials should be performed to ensure that the raw materials used in pharmaceutical products are suitable for their intended use. In this study, five commonly used Artemisia species included Artemisia argyi, Artemisia annua, Artemisia lavandulaefolia, Artemisia indica, and Artemisia atrovirens were analyzed using high resolution melting (HRM) analysis based on the internal transcribed spacer 2 (ITS2) sequences. The melting profiles of the ITS2 amplicons of the five closely related herbal species are clearly separated so that they can be differentiated by HRM method. The method was further applied to authenticate commercial products in powdered. HRM curves of all the commercial samples tested are similar to the botanical species as labeled. These congeneric medicinal products were also clearly separated using the neighbor-joining (NJ) tree. Therefore, HRM method could provide an efficient and reliable authentication system to distinguish these commonly used Artemisia herbal products on the markets and offer a technical reference for medicines quality control in the drug supply chain.

  5. Regulatory and information support for evaluation of biological productivity of Ukrainian forests and climate change

    NASA Astrophysics Data System (ADS)

    Lakyda, Petro; Vasylyshyn, Roman; Lakyda, Ivan

    2013-04-01

    Stabilization and preservation of the planet's climate system today is regarded as one of the most important global political-economic, environmental and social problems of mankind. Rising concentration of carbon dioxide in the planet's atmosphere due to anthropogenic impact is the main reason leading to global climate change. Due to the above mentioned, social demands on forests are changing their biosphere role and function of natural sink of greenhouse gases becomes top priority. It is known that one of the most essential components of biological productivity of forests is their live biomass. Absorption, long-term sequestration of carbon and generation of oxygen are secured by its components. System research of its parametric structure and development of regulatory and reference information for assessment of aboveground live biomass components of trees and stands of the main forest-forming tree species in Ukraine began over twenty-five years ago at the department of forest mensuration and forest inventory of National University of Life and Environmental Sciences of Ukraine, involving staff from other research institutions. Today, regulatory and reference materials for evaluation of parametric structure of live biomass are developed for trees of the following major forest-forming tree species of Ukraine: Scots pine of natural and artificial origin, Crimean pine, Norway spruce, silver fir, pedunculate oak, European beech, hornbeam, ash, common birch, aspen and black alder (P.I. Lakyda et al., 2011). An ongoing process on development of similar regulatory and reference materials for forest stands of the abovementioned forest-forming tree species of Ukraine is secured by scientists of departments of forest management, and forest mensuration and forest inventory. The total experimental research base is 609 temporary sample plots, where 4880 model trees were processed, including 3195 model trees with estimates of live biomass components. Laboratory studies conducted on 1743 research sections of tree stems, 809 samples of crown branches, 2560 model tree greenery branches, 346 batches of needles and 534 batches of leaves. These materials have high scientific and practical value, forming a basis for quantitative evaluation of biological productivity of forests in Ukraine, which are of great importance for mitigation of climate change. They also can be used as a data source for development of systems of models of various purposes, which find their application in Ukrainian and world forest science and practice.

  6. THCVA-A - a new additional marker for illegal cannabis consumption.

    PubMed

    Radünz, Lars; Westphal, Folker; Maser, Edmund; Rochholz, Gertrud

    2012-02-10

    The aim of the present investigations was to find markers for differentiating between the consumption of illegal cannabis products and legal medication containing fully synthetic Δ9-tetrahydrocannabinol (Δ9-THC), e.g., Marinol capsules. Δ9-Tetrahydrocannabinolic acid A (Δ9-THCA-A) and Δ9-tetrahydrocannabivarinic acid A (Δ9-THCVA-A) were taken into consideration for analysis, because these substances are the precursors of Δ9-THC and Δ9-tetrahydrocannabivarin (Δ9-THCV) in plant material of Cannabis sativa and are not contained in medical THC formulations. Whereas Δ9-THCA-A is an already well investigated substance, there is little analytical data on Δ9-THCVA-A. The reason for the presented investigations was a case in which a man was tested positive for Δ9-THC during a routine traffic control claiming that the positive serum sample resulted from the intake of a THC medication (Marinol) and not from consuming illegal cannabis products. Sample preparation consisted of a protein precipitation with acetonitrile. Analysis was carried out on a Thermo Fisher LCQ Deca ion trap LC-MS-MS-system using electron spray ionization (ESI) in negative mode. MS(2)- and MS(3)-full scan spectra were recorded for Δ9-THCA-A and Δ9-THCVA-A starting from [M-H](-). Reference spectra were obtained by measuring a Δ9-THCA-A reference solution and an ethanolic cannabis extract for Δ9-THCVA-A as there is no reference material for this cannabinoid available on the market yet. Main transitions for Δ9-THCA-A were m/z 357→313 and 339 in the MS(2)-spectrum and m/z 313→245 and 191 in the MS(3)-spectrum. Fragmentation pattern of Δ9-THCVA-A was identical with a difference of 28 amu less for the precursor ion as well as the fragments due to a shorter alkyl side chain in the molecule (MS(2): m/z 329→285 and 311; MS(3): m/z 285→217 and 163). The two plant cannabinoids Δ9-THCA-A and Δ9-THCVA-A could be detected in the serum sample by LC-MS-MS which proved the intake of illegal cannabis products derived from plant material of C. sativa in the described case. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  7. High-precision isotopic characterization of USGS reference materials by TIMS and MC-ICP-MS

    NASA Astrophysics Data System (ADS)

    Weis, Dominique; Kieffer, Bruno; Maerschalk, Claude; Barling, Jane; de Jong, Jeroen; Williams, Gwen A.; Hanano, Diane; Pretorius, Wilma; Mattielli, Nadine; Scoates, James S.; Goolaerts, Arnaud; Friedman, Richard M.; Mahoney, J. Brian

    2006-08-01

    The Pacific Centre for Isotopic and Geochemical Research (PCIGR) at the University of British Columbia has undertaken a systematic analysis of the isotopic (Sr, Nd, and Pb) compositions and concentrations of a broad compositional range of U.S. Geological Survey (USGS) reference materials, including basalt (BCR-1, 2; BHVO-1, 2), andesite (AGV-1, 2), rhyolite (RGM-1, 2), syenite (STM-1, 2), granodiorite (GSP-2), and granite (G-2, 3). USGS rock reference materials are geochemically well characterized, but there is neither a systematic methodology nor a database for radiogenic isotopic compositions, even for the widely used BCR-1. This investigation represents the first comprehensive, systematic analysis of the isotopic composition and concentration of USGS reference materials and provides an important database for the isotopic community. In addition, the range of equipment at the PCIGR, including a Nu Instruments Plasma MC-ICP-MS, a Thermo Finnigan Triton TIMS, and a Thermo Finnigan Element2 HR-ICP-MS, permits an assessment and comparison of the precision and accuracy of isotopic analyses determined by both the TIMS and MC-ICP-MS methods (e.g., Nd isotopic compositions). For each of the reference materials, 5 to 10 complete replicate analyses provide coherent isotopic results, all with external precision below 30 ppm (2 SD) for Sr and Nd isotopic compositions (27 and 24 ppm for TIMS and MC-ICP-MS, respectively). Our results also show that the first- and second-generation USGS reference materials have homogeneous Sr and Nd isotopic compositions. Nd isotopic compositions by MC-ICP-MS and TIMS agree to within 15 ppm for all reference materials. Interlaboratory MC-ICP-MS comparisons show excellent agreement for Pb isotopic compositions; however, the reproducibility is not as good as for Sr and Nd. A careful, sequential leaching experiment of three first- and second-generation reference materials (BCR, BHVO, AGV) indicates that the heterogeneity in Pb isotopic compositions, and concentrations, could be directly related to contamination by the steel (mortar/pestle) used to process the materials. Contamination also accounts for the high concentrations of certain other trace elements (e.g., Li, Mo, Cd, Sn, Sb, W) in various USGS reference materials.

  8. Optimizing product life cycle processes in design phase

    NASA Astrophysics Data System (ADS)

    Faneye, Ola. B.; Anderl, Reiner

    2002-02-01

    Life cycle concepts do not only serve as basis in assisting product developers understand the dependencies between products and their life cycles, they also help in identifying potential opportunities for improvement in products. Common traditional concepts focus mainly on energy and material flow across life phases, necessitating the availability of metrics derived from a reference product. Knowledge of life cycle processes won from an existing product is directly reused in its redesign. Depending on sales volume nevertheless, the environmental impact before product optimization can be substantial. With modern information technologies today, computer-aided life cycle methodologies can be applied well before product use. On the basis of a virtual prototype, life cycle processes are analyzed and optimized, using simulation techniques. This preventive approach does not only help in minimizing (or even eliminating) environmental burdens caused by product, costs incurred due to changes in real product can also be avoided. The paper highlights the relationship between product and life cycle and presents a computer-based methodology for optimizing the product life cycle during design, as presented by SFB 392: Design for Environment - Methods and Tools at Technical University, Darmstadt.

  9. Do forests best mitigate CO2 emissions to the atmosphere by setting them aside for maximization of carbon storage or by management for fossil fuel substitution?

    PubMed

    Taeroe, Anders; Mustapha, Walid Fayez; Stupak, Inge; Raulund-Rasmussen, Karsten

    2017-07-15

    Forests' potential to mitigate carbon emissions to the atmosphere is heavily debated and a key question is if forests left unmanaged to store carbon in biomass and soil provide larger carbon emission reductions than forests kept under forest management for production of wood that can substitute fossil fuels and fossil fuel intensive materials. We defined a modelling framework for calculation of the carbon pools and fluxes along the forest energy and wood product supply chains over 200 years for three forest management alternatives (FMA): 1) a traditionally managed European beech forest, as a business-as-usual case, 2) an energy poplar plantation, and 3) a set-aside forest left unmanaged for long-term storage of carbon. We calculated the cumulative net carbon emissions (CCE) and carbon parity times (CPT) of the managed forests relative to the unmanaged forest. Energy poplar generally had the lowest CCE when using coal as the reference fossil fuel. With natural gas as the reference fossil fuel, the CCE of the business-as-usual and the energy poplar was nearly equal, with the unmanaged forest having the highest CCE after 40 years. CPTs ranged from 0 to 156 years, depending on the applied model assumptions. CCE and CPT were especially sensitive to the reference fossil fuel, material alternatives to wood, forest growth rates for the three FMAs, and energy conversion efficiencies. Assumptions about the long-term steady-state levels of carbon stored in the unmanaged forest had a limited effect on CCE after 200 years. Analyses also showed that CPT was not a robust measure for ranking of carbon mitigation benefits. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. An economical approach for d-lactic acid production utilizing unpolished rice from aging paddy as major nutrient source.

    PubMed

    Lu, Zhengdong; Lu, Mingbo; He, Feng; Yu, Longjiang

    2009-03-01

    In order to reduce the raw material cost of d-lactic acid fermentation, the unpolished rice from aging paddy was used as major nutrient source in this study. The unpolished rice saccharificate, wheat bran powder and yeast extract were employed as carbon source, nitrogen source and growth factors, respectively. Response surface methodology (RSM) was applied to optimize the dosages of medium compositions. As a result, when the fermentation was carried out under the optimal conditions for wheat bran powder (29.10g/l) and yeast extract (2.50g/l), the d-lactic acid yield reached 731.50g/kg unpolished rice with a volumetric production rate of 1.50g/(lh). In comparison with fresh corn and polished rice, the d-lactic acid yield increased by 5.79% and 8.71%, and the raw material cost decreased by 65% and 52%, respectively, when the unpolished rice was used as a major nutrient source. These results might provide a reference for the industrial production of d-lactic acid.

  11. [Report of the NEDO project "Research and development to promote the creation and utilization of an intellectual infrastructure: development of reference materials for laboratory medicine" "Development of pure substance-type certified reference materials"].

    PubMed

    Takatsu, Akiko

    2009-06-01

    There is an increasing demand to establish a metrological traceability system for in vitro diagnostics and medical devices. Pure substance-type reference materials are playing key roles in metrological traceability, because they form the basis for many traceability chains in chemistry. The National Metrology Institute of Japan (NMIJ), in the National Institute of Advanced Industrial Science and Technology (AIST), has been developing purity-certified reference materials (CRMs) in this field, such as cholesterol, creatinine, and urea. In the New Energy and Industrial Technology Development Organization (NEDO) project, entitled: "Research and Development to Promote the Creation and Utilization of an Intellectual Infrastructure: Development of Reference Materials for Laboratory Medicine", several pure substance-type CRMs were developed. For a pure protein solution CRM, amino acid analysis and nitrogen determination were chosen as the certification methods. The development and certification processes for the C-reactive protein (CRP) solution CRM were completed, with the recombinant human CRP solution as a candidate material. This CRP solution CRM is now available as NMIJ CRM. For cortisol CRM, a purified candidate material and highly pure primary reference material were prepared. Each impure compound in the materials was identified and quantified. The pure cortisol CRM will be available in 2009. These two CRMs provide a traceability link between routine clinical methods and the SI unit.

  12. DOE research and development report. Progress report, October 1980-September 1981

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bingham, Carleton D.

    The DOE New Brunswick Laboratory (NBL) is the US Government's Nuclear Materials Standards and Measurement Laboratory. NBL is assigned the mission to provide and maintain, as an essential part of federal statutory responsibilities related to national and international safeguards of nuclear materials for USA defense and energy programs, an ongoing capability for: the development, preparation, certification, and distribution of reference materials for the calibration and standardization of nuclear materials measurements; the development, improvement, and evaluation of nuclear materials measurement technology; the assessment and evaluation of the practice and application of nuclear materials measurement technology; expert and reliable specialized nuclear materialsmore » measurement services for the government; and technology exchange and training in nuclear materials measurement and standards. Progress reports for this fiscal year are presented under the following sections: (1) development or evaluation of measurement technology (elemental assay of uranium plutonium; isotope composition); (2) standards and reference materials (NBL standards and reference materials; NBS reference materials); and (3) evaluation programs (safeguards analytical laboratory evaluation; general analytical evaluation program; other evaluation programs).« less

  13. Modeling and Depletion Simulations for a High Flux Isotope Reactor Cycle with a Representative Experiment Loading

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chandler, David; Betzler, Ben; Hirtz, Gregory John

    2016-09-01

    The purpose of this report is to document a high-fidelity VESTA/MCNP High Flux Isotope Reactor (HFIR) core model that features a new, representative experiment loading. This model, which represents the current, high-enriched uranium fuel core, will serve as a reference for low-enriched uranium conversion studies, safety-basis calculations, and other research activities. A new experiment loading model was developed to better represent current, typical experiment loadings, in comparison to the experiment loading included in the model for Cycle 400 (operated in 2004). The new experiment loading model for the flux trap target region includes full length 252Cf production targets, 75Se productionmore » capsules, 63Ni production capsules, a 188W production capsule, and various materials irradiation targets. Fully loaded 238Pu production targets are modeled in eleven vertical experiment facilities located in the beryllium reflector. Other changes compared to the Cycle 400 model are the high-fidelity modeling of the fuel element side plates and the material composition of the control elements. Results obtained from the depletion simulations with the new model are presented, with a focus on time-dependent isotopic composition of irradiated fuel and single cycle isotope production metrics.« less

  14. Novel Miscanthus Germplasm-Based Value Chains: A Life Cycle Assessment

    PubMed Central

    Wagner, Moritz; Kiesel, Andreas; Hastings, Astley; Iqbal, Yasir; Lewandowski, Iris

    2017-01-01

    In recent years, considerable progress has been made in miscanthus research: improvement of management practices, breeding of new genotypes, especially for marginal conditions, and development of novel utilization options. The purpose of the current study was a holistic analysis of the environmental performance of such novel miscanthus-based value chains. In addition, the relevance of the analyzed environmental impact categories was assessed. A Life Cycle Assessment was conducted to analyse the environmental performance of the miscanthus-based value chains in 18 impact categories. In order to include the substitution of a reference product, a system expansion approach was used. In addition, a normalization step was applied. This allowed the relevance of these impact categories to be evaluated for each utilization pathway. The miscanthus was cultivated on six sites in Europe (Aberystwyth, Adana, Moscow, Potash, Stuttgart and Wageningen) and the biomass was utilized in the following six pathways: (1) small-scale combustion (heat)—chips; (2) small-scale combustion (heat)—pellets; (3) large-scale combustion (CHP)—biomass baled for transport and storage; (4) large-scale combustion (CHP)—pellets; (5) medium-scale biogas plant—ensiled miscanthus biomass; and (6) large-scale production of insulation material. Thus, in total, the environmental performance of 36 site × pathway combinations was assessed. The comparatively high normalized results of human toxicity, marine, and freshwater ecotoxicity, and freshwater eutrophication indicate the relevance of these impact categories in the assessment of miscanthus-based value chains. Differences between the six sites can almost entirely be attributed to variations in biomass yield. However, the environmental performance of the utilization pathways analyzed varied widely. The largest differences were shown for freshwater and marine ecotoxicity, and freshwater eutrophication. The production of insulation material had the lowest impact on the environment, with net benefits in all impact categories expect three (marine eutrophication, human toxicity, agricultural land occupation). This performance can be explained by the multiple use of the biomass, first as material and subsequently as an energy carrier, and by the substitution of an emission-intensive reference product. The results of this study emphasize the importance of assessing all environmental impacts when selecting appropriate utilization pathways. PMID:28642784

  15. Inter-laboratory comparison of elemental analysis and gas chromatography combustion isotope ratio mass spectrometry (GC-C-IRMS). Part I: delta13C measurements of selected compounds for the development of an isotopic Grob-test.

    PubMed

    Serra, F; Janeiro, A; Calderone, G; Rojas, J M Moreno; Rhodes, C; Gonthier, L A; Martin, F; Lees, M; Mosandl, A; Sewenig, S; Hener, U; Henriques, B; Ramalho, L; Reniero, F; Teixeira, A J; Guillou, C

    2007-03-01

    This study was directed towards investigating suitable compounds to be used as stable isotope reference materials for gas chromatography combustion isotope ratio mass spectrometry (GC-C-IRMS) calibration. Several compounds were selected from those used in the 'Grob-test' mixture. Oxygen- and nitrogen-containing substances were added to these compounds to allow the mixture to be used as a possible multi-isotopic calibration tool for 2H/1H, 13C/12C, 15N/14N and 18O/16O ratio determinations. In this paper we present the results of delta13C measurements performed by the consortium of the five laboratories taking part in this inter-calibration exercise. All the compounds were individually assessed for homogeneity, short-term stability and long-term stability by means of EA-IRMS, as required by the bureau communitaire de reference (BCR) Guide for Production of Certified Reference Materials. The results were compared then with the GC-C-IRMS measurements using both polar and non-polar columns, and the final mixture of selected compounds underwent a further certification exercise assessing limits of accuracy and reproducibility under specified GC-C-IRMS conditions. Copyright 2007 John Wiley & Sons, Ltd.

  16. A Reference Method for Measuring Emissions of SVOCs in ...

    EPA Pesticide Factsheets

    Semivolatile organic compounds (SVOCs) are indoor air pollutants that may may have significant adverse effects on human health, and emission of SVOCs from building materials and consumer products is of growing concern. Few chamber studies have been conducted due to the challenges associated with SVOC analysis and the lack of validation procedures. Thus there is an urgent need for a reliable and accurate chamber test method to verify the performance of these measurements. A reference method employing a specially-designed chamber and experimental protocol has been developed and is undergoing extensive evaluation. A pilot interlaboratory study (ILS) has been conducted with five laboratories performing chamber tests under identical conditions. Results showed inter-laboratory variations at 25% for SVOC emission rates, with greater agreement observed between intra-laboratory measurements for most of the participating laboratories. The measured concentration profiles also compared reasonably well to the mechanistic model, demonstrating the feasibility of the proposed reference method to independently assess laboratory performance and validate SVOC emission tests. There is an urgent need for improved understanding of the measurement uncertainties associated with SVOC emissions testing. The creation of specially-designed chambers and well-characterized materials serves as a critical prerequisite for improving the procedure used to measure SVOCs emitted from indoor

  17. Fibrinolysis standards: a review of the current status.

    PubMed

    Thelwell, C

    2010-07-01

    Biological standards are used to calibrate measurements of components of the fibrinolytic system, either for assigning potency values to therapeutic products, or to determine levels in human plasma as an indicator of thrombotic risk. Traditionally WHO International Standards are calibrated in International Units based on consensus values from collaborative studies. The International Unit is defined by the response activity of a given amount of the standard in a bioassay, independent of the method used. Assay validity is based on the assumption that both standard and test preparation contain the same analyte, and the response in an assay is a true function of this analyte. This principle is reflected in the diversity of source materials used to prepare fibrinolysis standards, which has depended on the contemporary preparations they were employed to measure. With advancing recombinant technology, and improved analytical techniques, a reference system based on reference materials and associated reference methods has been recommended for future fibrinolysis standards. Careful consideration and scientific judgement must however be applied when deciding on an approach to develop a new standard, with decisions based on the suitability of a standard to serve its purpose, and not just to satisfy a metrological ideal. 2010 The International Association for Biologicals. Published by Elsevier Ltd. All rights reserved.

  18. Fire Safety Aspects of Polymeric Materials. Volume 3. Smoke and Toxicity (Combustion Toxicology of Polymers)

    DTIC Science & Technology

    1978-01-01

    Analytical Test Methodology Sampling and analysis of thermal decomposition products are formidable tasks (Rasbash, 1967; Gaskill, 1973; Bankston ...by a flowing solution. A Sample Gas Inlet B Alkali Solution Inlet C Gas and Solution Outlet D Specific Ion Electrode E Reference Electrode E D 1 0 1 2...of radiant heat (Zinn, Powell, Cassanova and Bankston , 1977) ° Seader and Ou have recently proposed a theory relating optical density to particulate

  19. Establishment of a Plasma Melting Manufacturing Process for Production of Nickel-Base Alloys.

    DTIC Science & Technology

    1975-05-01

    7.1 Conclusions 40 7.2 Recommendations 41 8.0 REFERENCES ^2 1 . . . -— - •- - — ■•- lin ■■ - - -- - 1 ^H , r...high nitrogen steel is similar in chemical com- position to the Nitronic series marketed by Armco Steel in the U.S.A. The plasmarc remelted material in...the cast condition displays good ductility and yield strength comparable to Armco’s nitrogen strengthened austenitic steel Nitronic ^0. The Soviet

  20. ANSI-ASQ National Accreditation Board /ACLASS

    DTIC Science & Technology

    2011-03-28

    unclassified c. THIS PAGE unclassified Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18  Laboratories – ISO / IEC 17025  Inspection...Bodies – ISO / IEC 17020  RMPs – ISO Guide 34 (Reference Materials)  PT Providers – ISO 17043  Product Certifiers – ISO Guide 65  Government...Programs: DoD ELAP, EPA Energy Star, CPSC Toy Safety, NRC, NIST IPV6, NLLAP, NEFAP  TRAINING Programs  Certification Bodies – ISO / IEC 17021

  1. delta 15N and non-carbonate delta 13C values for two petroleum source rock reference materials and a marine sediment reference material

    USGS Publications Warehouse

    Dennen, Kristin O.; Johnson, Craig A.; Otter, Marshall L.; Silva, Steven R.; Wandless, Gregory A.

    2006-01-01

    Samples of United States Geological Survey (USGS) Certified Reference Materials USGS Devonian Ohio Shale (SDO-1), and USGS Eocene Green River Shale (SGR-1), and National Research Council Canada (NRCC) Certified Marine Sediment Reference Material (PACS-2), were sent for analysis to four separate analytical laboratories as blind controls for organic rich sedimentary rock samples being analyzed from the Red Dog mine area in Alaska. The samples were analyzed for stable isotopes of carbon (delta13Cncc) and nitrogen (delta15N), percent non-carbonate carbon (Wt % Cncc) and percent nitrogen (Wt % N). SDO-1, collected from the Huron Member of the Ohio Shale, near Morehead, Kentucky, and SGR-1, collected from the Mahogany zone of the Green River Formation are petroleum source rocks used as reference materials for chemical analyses of sedimentary rocks. PACS-2 is modern marine sediment collected from the Esquimalt, British Columbia harbor. The results presented in this study are, with the exceptions noted below, the first published for these reference materials. There are published information values for the elemental concentrations of 'organic' carbon (Wt % Corg measured range is 8.98 - 10.4) and nitrogen (Wt % Ntot 0.347 with SD 0.043) only for SDO-1. The suggested values presented here should be considered 'information values' as defined by the NRCC Institute for National Measurement Reference Materials and should be useful for the analysis of 13C, 15N, C and N in organic material in sedimentary rocks.

  2. Biscayne aquifer drinking water (USGS45): a new isotopic reference material for δ2H and δ18O measurements of water

    USGS Publications Warehouse

    Lorenz, Jennifer M.; Tarbox, Lauren V.; Buck, Bryan; Qi, Haiping; Coplen, Tyler B.

    2014-01-01

    RATIONALE As a result of the scarcity of isotopic reference waters for daily use, a new secondary isotopic reference material for international distribution has been prepared from drinking water collected from the Biscayne aquifer in Ft. Lauderdale, Florida. METHODS This isotopic reference water was filtered, homogenized, loaded into glass ampoules, sealed with a torch, autoclaved to eliminate biological activity, and measured by dual-inlet isotope-ratio mass spectrometry. This reference material is available by the case of 144 glass ampoules containing either 4 mL or 5 mL of water in each ampoule. RESULTS The δ2H and δ18O values of this reference material are –10.3 ± 0.4 ‰ and –2.238 ± 0.011 ‰, respectively, relative to VSMOW, on scales normalized such that the δ2H and δ18O values of SLAP reference water are, respectively, –428 and –55.5 ‰. Each uncertainty is an estimated expanded uncertainty (U = 2uc) about the reference value that provides an interval that has about a 95 % probability of encompassing the true value. CONCLUSIONS This isotopic reference material, designated as USGS45, is intended as one of two isotopic reference waters for daily normalization of stable hydrogen and oxygen isotopic analysis of water with an isotope-ratio mass spectrometer or a laser absorption spectrometer. 

  3. DNA barcode based wildlife forensics for resolving the origin of claw samples using a novel primer cocktail.

    PubMed

    Khedkar, Gulab D; Abhayankar, Shil Bapurao; Nalage, Dinesh; Ahmed, Shaikh Nadeem; Khedkar, Chandraprakash D

    2016-11-01

    Excessive wildlife hunting for commercial purposes can have negative impacts on biodiversity and may result in species extinction. To ensure compliance with legal statutes, forensic identification approaches relying on molecular markers may be used to identify the species of origin of animal material from hairs, claw, blood, bone, or meat. Using this approach, DNA sequences from the COI "barcoding" gene have been used to identify material from a number of domesticated animal species. However, many wild species of carnivores still present great challenges in generating COI barcodes using standard "universal" primer pairs. In the work presented here, the mitochondrial COI gene was successfully amplified using a novel primer cocktail, and the products were sequenced to determine the species of twenty one unknown samples of claw material collected as part of forensic wildlife case investigations. Sixteen of the unknown samples were recognized to have originated from either Panthera leo or P. pardus individuals. The remaining five samples could be identified only to the family level due to the absence of reference animal sequences. This is the first report on the use of COI sequences for the identification of P. pardus and P. leo from claw samples as part of forensic investigations in India. The study also highlights the need for adequate reference material to aid in the resolution of suspected cases of illegal wildlife harvesting.

  4. Drivers of U.S. mineral demand

    USGS Publications Warehouse

    Sznopek, John L.

    2006-01-01

    Introduction: The word 'demand' has different meanings for different people. To some, it means their 'wants and needs,' to others it is what they consume. Yet, when considering economics, demand refers to the specific amounts of goods or services that individuals will purchase at various prices. Demand is measured over a given time period. It is determined by a number of factors including income, tastes, and the price of complementary and substitute goods. In this paper, the term consumption is used fairly synonymously with the term demand. Most mineral commodities, like iron ore, copper, zinc, and gravel, are intermediate goods, which means that they are used in the production of other goods, called final goods. Demand for intermediate goods is called derived demand because such demand is derived from the demand for final goods. When demand increases for a commodity, generally the price rises. With everything else held constant, this increases the profits for those who provide this commodity. Normally, this would increase profits of existing producers and attract new producers to the market. When demand for a commodity decreases, generally the price falls. Normally, this would cause profits to fall and, as a consequence, the least efficient firms may be forced from the industry. Demand changes for specific materials as final goods or production techniques are reengineered while maintaining or improving product performance, for example, the use of aluminum in the place of copper in long distance electrical transmission lines or plastic replacing steel in automobile bumpers. Substitution contributes to efficient material usage by utilizing cheaper or technically superior materials. In this way, it may also alleviate materials scarcity. If a material becomes relatively scarce (and thus more expensive), a more abundant (and less expensive) material generally replaces it (Wagner and others, 2003, p. 91).

  5. Impact of a product-specific reference standard for the measurement of a PEGylated rFVIII activity: the Swiss Multicentre Field Study.

    PubMed

    Bulla, O; Poncet, A; Alberio, L; Asmis, L M; Gähler, A; Graf, L; Nagler, M; Studt, J-D; Tsakiris, D A; Fontana, P

    2017-07-01

    Measuring factor VIII (FVIII) activity can be challenging when it has been modified, such as when FVIII is pegylated to increase its circulating half-life. Use of a product-specific reference standard may help avoid this issue. Evaluate the impact of using a product-specific reference standard for measuring the FVIII activity of BAX 855 - a pegylated FVIII - in eight of Switzerland's main laboratories. Factor VIII-deficient plasma, spiked with five different concentrations of BAX 855, plus a control FVIII sample, was sent to the participating laboratories. They measured FVIII activity by using either with a one-stage (OSA) or the chromogenic assay (CA) against their local or a product-specific reference standard. When using a local reference standard, there was an overestimation of BAX 855 activity compared to the target concentrations, both with the OSA and CA. The use of a product-specific reference standard reduced this effect: mean recovery ranged from 127.7% to 213.5% using the OSA with local reference standards, compared to 110% to 183.8% with a product-specific reference standard, and from 146.3% to 182.4% using the CA with local reference standards compared to 72.7% to 103.7% with a product-specific reference standard. In this in vitro study, the type of reference standard had a major impact on the measurement of BAX 855 activity. Evaluation was more accurate and precise when using a product-specific reference standard. © 2017 John Wiley & Sons Ltd.

  6. The effectiveness of physics learning material based on South Kalimantan local wisdom

    NASA Astrophysics Data System (ADS)

    Hartini, Sri; Misbah, Helda, Dewantara, Dewi

    2017-08-01

    The local wisdom is essential element incorporated into learning process. However, there are no learning materials in Physics learning process which contain South Kalimantan local wisdom. Therefore, it is necessary to develop a Physics learning material based on South Kalimantan local wisdom. The objective of this research is to produce products in the form of learning material based on South Kalimantan local wisdom that is feasible and effective based on the validity, practicality, effectiveness of learning material and achievement of waja sampai kaputing (wasaka) character. This research is a research and development which refers to the ADDIE model. Data were obtained through the validation sheet of learning material, questionnaire, the test of learning outcomes and the sheet of character assesment. The research results showed that (1) the validity category of the learning material was very valid, (2) the practicality category of the learning material was very practical, (3) the effectiveness category of thelearning material was very effective, and (4) the achivement of wasaka characters was very good. In conclusion, the Physics learning materials based on South Kalimantan local wisdom are feasible and effective to be used in learning activities.

  7. 33 CFR 140.7 - Incorporation by reference.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... materials are incorporated by reference into this subchapter with the approval of the Director of the... material made available to the public. All approved material is available for inspection at U.S. Coast... National Archives and Records Administration (NARA). For information on the availability of this material...

  8. 33 CFR 140.7 - Incorporation by reference.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... materials are incorporated by reference into this subchapter with the approval of the Director of the... material made available to the public. All approved material is available for inspection at U.S. Coast... National Archives and Records Administration (NARA). For information on the availability of this material...

  9. 33 CFR 140.7 - Incorporation by reference.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... materials are incorporated by reference into this subchapter with the approval of the Director of the... material made available to the public. All approved material is available for inspection at U.S. Coast... National Archives and Records Administration (NARA). For information on the availability of this material...

  10. 33 CFR 140.7 - Incorporation by reference.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... materials are incorporated by reference into this subchapter with the approval of the Director of the... material made available to the public. All approved material is available for inspection at U.S. Coast... National Archives and Records Administration (NARA). For information on the availability of this material...

  11. 33 CFR 140.7 - Incorporation by reference.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... materials are incorporated by reference into this subchapter with the approval of the Director of the... material made available to the public. All approved material is available for inspection at U.S. Coast... National Archives and Records Administration (NARA). For information on the availability of this material...

  12. Solar cell array design handbook, volume 1

    NASA Technical Reports Server (NTRS)

    Rauschenbach, H. S.

    1976-01-01

    Twelve chapters discuss the following: historical developments, the environment and its effects, solar cells, solar cell filters and covers, solar cell and other electrical interconnections, blocking and shunt diodes, substrates and deployment mechanisms, material properties, design synthesis and optimization, design analysis, procurement, production and cost aspects, evaluation and test, orbital performance, and illustrative design examples. A comprehensive index permits rapid locating of desired topics. The handbook consists of two volumes: Volume 1 is of an expository nature while Volume 2 contains detailed design data in an appendix-like fashion. Volume 2 includes solar cell performance data, applicable unit conversion factors and physical constants, and mechanical, electrical, thermal optical, magnetic, and outgassing material properties. Extensive references are provided.

  13. Embodied labour in music work.

    PubMed

    Pettinger, Lynne

    2015-06-01

    This paper frames the work of performance as embodied labour in order to understand the contingent production of particular music performances. It is an interdisciplinary account that sits at the intersection of the sociology of work, culture and the body. The concept of embodied labour is developed with reference to the complex account of materiality - of bodies and things - present in Tim Ingold's account of skill. This material account of skill is used to inform use to develop already of well established conceptualizations of body labour: craft, emotional and aesthetic labour through a reading of how these dimensions of embodied labour make possible the work of performance. © London School of Economics and Political Science 2015.

  14. PCM-enhanced lime plasters for vernacular and contemporary architecture

    NASA Astrophysics Data System (ADS)

    Theodoridou, Magdalini; Kyriakou, Loucas; Ioannou, Ioannis

    2016-04-01

    In 1997, the European Union (EU) pledged to reduce the amount of greenhouse gas emissions by 20% below the levels of 1990 by the end of 2020. In recent years it has become evident that, in order to reach that goal, EU Member States must take measures to encourage sustainability in the building industry, which is a major energy consumer. Such measures should involve the use of innovative, environmentally friendly materials and methods in new constructions, as well as the renovation of existing properties by upgrading their current state of energy efficiency. Phase Change Materials (PCMs) have the ability to absorb and release thermal energy, in the form of latent heat, during the melting or solidifying processes respectively. Thus, they may be used as additives in the production of thermally efficient composite building materials. A PCM-enhanced plaster is a heat storage medium combining an appropriate PCM with a cementitious or non-cementitious matrix to produce a low-cost thermal storage material with structural and thermostatic properties. Although innovative technologies, such as PCMs, have certainly contributed to the boost in the evolution of the building materials industry in recent years, a significant proportion of these technologies and practices have not yet been fully exploited in materials based on traditional principles. This paper focuses on the design and production of novel cementless PCM-enhanced lime plasters, in line with the traditional production technology of lime composites. The new plasters are produced using either hydrated or natural hydraulic lime binder, crushed calcarenite sand (0-2 mm) and commercial microencapsulated PCM in powder form (5% w/w of solids). Results from comparative tests between reference mixtures and mixtures with the addition of PCM, carried out 28, 56 and 90 days after laboratory production, prove the potential of PCMs in enhancing the thermal performance of traditional lime-based composites. The modified composites have significantly lower (by 55%) thermal conductivity and increased (by almost 20%) specific heat capacity at 90 days after laboratory production. At the same time, even though porosity values are higher for the PCM-enhanced renders, compared to the reference mixtures, their capillary absorption coefficient is significantly reduced (up to 60%). This is of great importance in the case of renders and may well be an indication for better expected durability in the long-term. Regarding the mechanical properties of the laboratory composites, PCM addition seems to have a negative effect on the hydraulic plasters. In contrast, when PCM is added to the hydrated lime-based plaster, no change is observed for the flexural strength, while the compressive strength is notably improved (up to 36%). The apparently improved properties of the PCM-enhanced plasters render them particularly appropriate for application in southern European climatic conditions. Due to their compatibility with traditional substrate materials (e.g. natural stone), the aforementioned composites may be used not only in new contemporary structures, but also for the renovation and retrofitting of existing buildings. The lime-based nature of their matrix and their physico-mechanical properties further extend their applicability to listed and monumental buildings.

  15. Assessment of Dredged Material Toxicity in San Francisco Bay

    DTIC Science & Technology

    1990-11-01

    reference sediment. When compared to the fine-grain Sequim Bay refer- ence material, no statistically significant mortalities were detected. R...Oakland Harbor. Sequim Bay material was used as the refer- ence. The hierarchy of interspecific sensitivity was oyster larvae > juvenile sand dabs...in San Francisco Bay 6. AUTHOR(S) Thomas M. Dillon, David W. Moore 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) - 8. PERFORMING ORGANIZATION

  16. Methods and instruments for materials testing

    NASA Technical Reports Server (NTRS)

    Hansma, Paul (Inventor); Drake, Barney (Inventor); Rehn, Douglas (Inventor); Adams, Jonathan (Inventor); Lulejian, Jason (Inventor)

    2011-01-01

    Methods and instruments for characterizing a material, such as the properties of bone in a living human subject, using a test probe constructed for insertion into the material and a reference probe aligned with the test probe in a housing. The housing is hand held or placed so that the reference probe contacts the surface of the material under pressure applied either by hand or by the weight of the housing. The test probe is inserted into the material to indent the material while maintaining the reference probe substantially under the hand pressure or weight of the housing allowing evaluation of a property of the material related to indentation of the material by the probe. Force can be generated by a voice coil in a magnet structure to the end of which the test probe is connected and supported in the magnet structure by a flexure, opposing flexures, a linear translation stage, or a linear bearing. Optionally, a measurement unit containing the test probe and reference probe is connected to a base unit with a wireless connection, allowing in the field material testing.

  17. Ultrasonic angle beam standard reflector. [ultrasonic nondestructive inspection

    NASA Technical Reports Server (NTRS)

    Berry, R. F., Jr. (Inventor)

    1985-01-01

    A method that provides an impression profile in a reference standard material utilized in inspecting critically stressed components with pulsed ultrasound is described. A die stamp having an I letter is used to impress the surface of a reference material. The die stamp is placed against the surface and struck with an inertia imparting member to impress the I in the reference standard material. Upset may appear on the surface as a result of the impression and is removed to form a smooth surface. The stamping and upset removal is repeated until the entire surface area of a depth control platform on the die stamp uniformly contacts the material surface. The I impression profile in the reference standard material is utilized for reflecting pulsed ultrasonic beams for inspection purposes.

  18. 15 CFR 230.7 - Description of services and list of fees, incorporation by reference.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... STANDARD REFERENCE MATERIALS STANDARD REFERENCE MATERIALS Description of Services and List of Fees § 230.7 Description of services and list of fees, incorporation by reference. (a) The text of NIST Special Publication... 15 Commerce and Foreign Trade 1 2010-01-01 2010-01-01 false Description of services and list of...

  19. National Nutrition Education Clearing House Reference List, Preschool, Primary and Intermediate Teaching Materials and Teacher References.

    ERIC Educational Resources Information Center

    National Nutrition Education Clearing House, Berkeley, CA.

    This is a reference list of teaching materials and teacher references of importance to teachers in the field of nutrition and nutrition education. It emphasizes resources for preschool, primary and intermediate grades. Although not a comprehensive list, resources include books, pamphlets, curriculum guides, article reprints, films and filmstrips,…

  20. Interlaboratory Reproducibility of Droplet Digital Polymerase Chain Reaction Using a New DNA Reference Material Format.

    PubMed

    Pinheiro, Leonardo B; O'Brien, Helen; Druce, Julian; Do, Hongdo; Kay, Pippa; Daniels, Marissa; You, Jingjing; Burke, Daniel; Griffiths, Kate; Emslie, Kerry R

    2017-11-07

    Use of droplet digital PCR technology (ddPCR) is expanding rapidly in the diversity of applications and number of users around the world. Access to relatively simple and affordable commercial ddPCR technology has attracted wide interest in use of this technology as a molecular diagnostic tool. For ddPCR to effectively transition to a molecular diagnostic setting requires processes for method validation and verification and demonstration of reproducible instrument performance. In this study, we describe the development and characterization of a DNA reference material (NMI NA008 High GC reference material) comprising a challenging methylated GC-rich DNA template under a novel 96-well microplate format. A scalable process using high precision acoustic dispensing technology was validated to produce the DNA reference material with a certified reference value expressed in amount of DNA molecules per well. An interlaboratory study, conducted using blinded NA008 High GC reference material to assess reproducibility among seven independent laboratories demonstrated less than 4.5% reproducibility relative standard deviation. With the exclusion of one laboratory, laboratories had appropriate technical competency, fully functional instrumentation, and suitable reagents to perform accurate ddPCR based DNA quantification measurements at the time of the study. The study results confirmed that NA008 High GC reference material is fit for the purpose of being used for quality control of ddPCR systems, consumables, instrumentation, and workflow.

  1. The Kjeldahl method as a primary reference procedure for total protein in certified reference materials used in clinical chemistry. II. Selection of direct Kjeldahl analysis and its preliminary performance parameters.

    PubMed

    Vinklárková, Bára; Chromý, Vratislav; Šprongl, Luděk; Bittová, Miroslava; Rikanová, Milena; Ohnútková, Ivana; Žaludová, Lenka

    2015-01-01

    To select a Kjeldahl procedure suitable for the determination of total protein in reference materials used in laboratory medicine, we reviewed in our previous article Kjeldahl methods adopted by clinical chemistry and found an indirect two-step analysis by total Kjeldahl nitrogen corrected for its nonprotein nitrogen and a direct analysis made on isolated protein precipitates. In this article, we compare both procedures on various reference materials. An indirect Kjeldahl method gave falsely lower results than a direct analysis. Preliminary performance parameters qualify the direct Kjeldahl analysis as a suitable primary reference procedure for the certification of total protein in reference laboratories.

  2. 49 CFR 572.80 - Incorporated materials.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 7 2011-10-01 2011-10-01 false Incorporated materials. 572.80 Section 572.80... Incorporated materials. The drawings and specifications referred to in § 572.81(a) that are not set forth in full are hereby incorporated in this part by reference. These materials are thereby made part of this...

  3. 10 CFR 431.15 - Materials incorporated by reference.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... approval, and a notice of any change in the material will be published in the Federal Register. All... 10 Energy 3 2014-01-01 2014-01-01 false Materials incorporated by reference. 431.15 Section 431.15... INDUSTRIAL EQUIPMENT Electric Motors Test Procedures, Materials Incorporated and Methods of Determining...

  4. 49 CFR 572.80 - Incorporated materials.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 7 2012-10-01 2012-10-01 false Incorporated materials. 572.80 Section 572.80... Incorporated materials. The drawings and specifications referred to in § 572.81(a) that are not set forth in full are hereby incorporated in this part by reference. These materials are thereby made part of this...

  5. 49 CFR 572.80 - Incorporated materials.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 7 2013-10-01 2013-10-01 false Incorporated materials. 572.80 Section 572.80... Incorporated materials. The drawings and specifications referred to in § 572.81(a) that are not set forth in full are hereby incorporated in this part by reference. These materials are thereby made part of this...

  6. 49 CFR 572.40 - Incorporated materials.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Register has approved the materials incorporated by reference. For materials subject to change, only the... incorporated. A notice of any change will be published in the Federal Register. As a convenience to the reader... volume of the Code of Federal Regulations. (b) The materials incorporated in this part by reference are...

  7. Assessment of international reference materials for isotope-ratio analysis (IUPAC Technical Report)

    USGS Publications Warehouse

    Brand, Willi A.; Coplen, Tyler B.; Vogl, Jochen; Rosner, Martin; Prohaska, Thomas

    2014-01-01

    Since the early 1950s, the number of international measurement standards for anchoring stable isotope delta scales has mushroomed from 3 to more than 30, expanding to more than 25 chemical elements. With the development of new instrumentation, along with new and improved measurement procedures for studying naturally occurring isotopic abundance variations in natural and technical samples, the number of internationally distributed, secondary isotopic reference materials with a specified delta value has blossomed in the last six decades to more than 150 materials. More than half of these isotopic reference materials were produced for isotope-delta measurements of seven elements: H, Li, B, C, N, O, and S. The number of isotopic reference materials for other, heavier elements has grown considerably over the last decade. Nevertheless, even primary international measurement standards for isotope-delta measurements are still needed for some elements, including Mg, Fe, Te, Sb, Mo, and Ge. It is recommended that authors publish the delta values of internationally distributed, secondary isotopic reference materials that were used for anchoring their measurement results to the respective primary stable isotope scale.

  8. Determination of tungsten in geochemical reference material basalt Columbia River 2 by radiochemical neutron activation analysis and inductively coupled plasma mass spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morrison, Samuel S.; Beck, Chelsie L.; Bowen, James M.

    Environmental tungsten (W) analyses are inhibited by a lack of reference materials and practical methods to remove isobaric and radiometric interferences. We present a method that evaluates the potential use of commercially available sediment, Basalt Columbia River-2 (BCR-2), as a reference material using neutron activation analysis (NAA) and mass spectrometry. Tungsten concentrations using both methods are in statistical agreement at the 95% confidence interval (92 ± 4 ng/g for NAA and 100 ±7 ng/g for mass spectrometry) with recoveries greater than 95%. These results indicate that BCR-2 may be suitable as a reference material for future studies.

  9. Claim validity of print advertisements found in otolaryngology journals.

    PubMed

    Del Signore, Anthony; Murr, Andrew H; Lustig, Lawrence R; Platt, Michael P; Jalisi, Scharukh; Pratt, Loring W; Spiegel, Jeffrey H

    2011-08-01

    To evaluate the accuracy and scientific evidence supporting product claims made in print advertisements within otolaryngology journals. Cross-sectional survey with literature review and multiple-reviewer evaluation. Fifty claims made within 23 unique advertisements found in prominent otolaryngology journals were selected. References to support the claims were provided within the advertisements or obtained through direct request to the manufacturer. Five academic otolaryngologists with distinct training and geographic practice locations reviewed the claims and supporting evidence. Each physician had substantial experience as an editorial reviewer, and several had specific training in research methodology and scientific methods. Of the 50 claims, only 14 were determined to be based on strong evidence (28%). With regard to the supporting references, 32 references were published sources (76%), while 3 references were package inserts and/or prescribing information (7%). Interobserver agreement among the reviewers overall was poor; however, when 3 or more of the reviewers were in agreement, only 10% of the claims were deemed correct (n = 5). Reviewers also noted that only 6% of the claims were considered well supported (n = 3). Advertisers make claims that appear in respectable journals, but greater than half of the claims reviewed were not supported by the provided reference materials.

  10. Certification of biological candidates reference materials by neutron activation analysis

    NASA Astrophysics Data System (ADS)

    Kabanov, Denis V.; Nesterova, Yulia V.; Merkulov, Viktor G.

    2018-03-01

    The paper gives the results of interlaboratory certification of new biological candidate reference materials by neutron activation analysis recommended by the Institute of Nuclear Chemistry and Technology (Warsaw, Poland). The correctness and accuracy of the applied method was statistically estimated for the determination of trace elements in candidate reference materials. The procedure of irradiation in the reactor thermal fuel assembly without formation of fast neutrons was carried out. It excluded formation of interfering isotopes leading to false results. The concentration of more than 20 elements (e.g., Ba, Br, Ca, Co, Ce, Cr, Cs, Eu, Fe, Hf, La, Lu, Rb, Sb, Sc, Ta, Th, Tb, Yb, U, Zn) in candidate references of tobacco leaves and bottom sediment compared to certified reference materials were determined. It was shown that the average error of the applied method did not exceed 10%.

  11. Quality assurance and quality control in light stable isotope laboratories: A case study of Rio Grande, Texas, water samples

    USGS Publications Warehouse

    Coplen, T.B.; Qi, H.

    2009-01-01

    New isotope laboratories can achieve the goal of reporting the same isotopic composition within analytical uncertainty for the same material analysed decades apart by (1) writing their own acceptance testing procedures and putting them into their mass spectrometric or laser-based isotope-ratio equipment procurement contract, (2) requiring a manufacturer to demonstrate acceptable performance using all sample ports provided with the instrumentation, (3) for each medium to be analysed, prepare two local reference materials substantially different in isotopic composition to encompass the range in isotopic composition expected in the laboratory and calibrated them with isotopic reference materials available from the International Atomic Energy Agency (IAEA) or the US National Institute of Standards and Technology (NIST), (4) using the optimum storage containers (for water samples, sealing in glass ampoules that are sterilised after sealing is satisfactory), (5) interspersing among sample unknowns local laboratory isotopic reference materials daily (internationally distributed isotopic reference materials can be ordered at three-year intervals, and can be used for elemental analyser analyses and other analyses that consume less than 1 mg of material) - this process applies to H, C, N, O, and S isotope ratios, (6) calculating isotopic compositions of unknowns by normalising isotopic data to that of local reference materials, which have been calibrated to internationally distributed isotopic reference materials, (7) reporting results on scales normalised to internationally distributed isotopic reference materials (where they are available) and providing to sample submitters the isotopic compositions of internationally distributed isotopic reference materials of the same substance had they been analysed with unknowns, (8) providing an audit trail in the laboratory for analytical results - this trail commonly will be in electronic format and might include a laboratory information management system, (9) making at regular intervals a complete backup of laboratory analytical data (both of samples logged into the laboratory and of mass spectrometric analyses), being sure to store one copy of this backup offsite, and (10) participating in interlaboratory comparison exercises sponsored by the IAEA and other agencies at regular intervals. ?? Taylor & Francis.

  12. Culturability of Bacillus spores on aerosol collection filters exposed to airborne combustion products of Al, Mg, and B·Ti.

    PubMed

    Adhikari, Atin; Yermakov, Michael; Indugula, Reshmi; Reponen, Tiina; Driks, Adam; Grinshpun, Sergey A

    2016-05-01

    Destruction of bioweapon facilities due to explosion or fire could aerosolize highly pathogenic microorganisms. The post-event air quality assessment is conducted through air sampling. A bioaerosol sample (often collected on a filter for further culture-based analysis) also contains combustion products, which may influence the microbial culturability and, thus, impact the outcome. We have examined the interaction between spores deposited on collection filters using two simulants of Bacillus anthracis [B. thuringiensis (Bt) and B. atrophaeus (referred to as BG)] and incoming combustion products of Al as well as Mg and B·Ti (common ingredient of metalized explosives). Spores extracted from Teflon, polycarbonate, mixed cellulose ester (MCE), and gelatin filters (most common filter media for bioaerosol sampling), which were exposed to combustion products during a short-term sampling, were analyzed by cultivation. Surprisingly, we observed that aluminum combustion products enhanced the culturability of Bt (but not BG) spores on Teflon filters increasing the culturable count by more than an order of magnitude. Testing polycarbonate and MCE filter materials also revealed a moderate increase of culturability although gelatin did not. No effect was observed with either of the two species interacting on either filter media with products originated by combustion of Mg and B·Ti. Sample contamination, spore agglomeration, effect of a filter material on the spore survival, changes in the spore wall ultrastructure and germination, as well as other factors were explored to interpret the findings. The study raises a question about the reliability of certain filter materials for collecting airborne bio-threat agents in combustion environments. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Proteome reference maps of Medicago truncatula embryogenic cell cultures generated from single protoplasts.

    PubMed

    Imin, Nijat; De Jong, Femke; Mathesius, Ulrike; van Noorden, Giel; Saeed, Nasir A; Wang, Xin-Ding; Rose, Ray J; Rolfe, Barry G

    2004-07-01

    Using a combination of two-dimensional gel electrophoresis (2-DE) protein mapping and mass spectrometry (MS) analysis, we have established proteome reference maps of Medicago truncatula embryogenic tissue culture cells. The cultures were generated from single protoplasts, which provided a relatively homogeneous cell population. We used these to analyze protein expression at the globular stages of somatic embryogenesis, which is the earliest morphogenetic embryonic stage. Over 3000 proteins could reproducibly be resolved over a pI range of 4-11. Three hundred and twelve protein spots were extracted from colloidal Coomassie Blue-stained 2-DE gels and analyzed by matrix-assisted laser desorption/ionization-time of flight MS analysis and tandem MS sequencing. This enabled the identification of 169 protein spots representing 128 unique gene products using a publicly available expressed sequence tag database and the MASCOT search engine. These reference maps will be valuable for the investigation of the molecular events which occur during somatic embryogenesis in M. truncatula. The proteome reference maps and supplementary materials will be available and updated for public access at http://semele.anu.edu.au/.

  14. Certification of caffeine reference material purity by ultraviolet/visible spectrophotometry and high-performance liquid chromatography with diode-array detection as two independent analytical methods.

    PubMed

    Shehata, A B; Rizk, M S; Rend, E A

    2016-10-01

    Caffeine reference material certified for purity is produced worldwide, but no research work on the details of the certification process has been published in the literature. In this paper, we report the scientific details of the preparation and certification of pure caffeine reference materials. Caffeine was prepared by extraction from roasted and ground coffee by dichloromethane after heating in deionized water mixed with magnesium oxide. The extract was purified, dried, and bottled in dark glass vials. Stratified random selection was applied to select a number of vials for homogeneity and stability studies, which revealed that the prepared reference material is homogeneous and sufficiently stable. Quantification of caffeine purity % was carried out using a calibrated UV/visible spectrophotometer and a calibrated high-performance liquid chromatography with diode-array detection method. The results obtained from both methods were combined to drive the certified value and its associated uncertainty. The certified value of the reference material purity was found to be 99.86% and its associated uncertainty was ±0.65%, which makes the candidate reference material a very useful calibrant in food and drug chemical analysis. Copyright © 2016. Published by Elsevier B.V.

  15. [Printed material distributed by pharmaceutical propaganda agents].

    PubMed

    Mejía, R; Avalos, A

    2001-01-01

    Pharmaceutical sales representatives (drug reps) frequently visit 70% to 90% of physicians during their daily clinical practice and many consider the promotional printed material to be a major source of clinical information. We evaluated samples of the promotional printed material distributed to physicians by drug reps in order to determine whether the data contained in the promotional material is correct and supported by references accessible in Argentina. A consecutive sample of all the promotional material distributed by drug reps in the general internal medicine program (Hospital de Clínicas) was collected between March 15 and April 15, 2000. Reprints and monographs were excluded. Clinical information was reviewed by two general internists and compared to information in a major pharmacology textbook and in an electronic medical information program. References cited were reviewed for correct listing and accessibility in any of the four major medical libraries in Buenos Aires. Of the sixty-four pieces of promotional material collected, thirty were randomly selected and evaluated. In twenty one (70%) the therapeutic effect promoted in advertisement appeared in Goodman & Gilman's 9th edition textbook of pharmacology, in the pharmacology section of the Up-to-Date version 8.1 or in both. Only eighteen (60%) of the thirty promotional printed material evaluated had statements supported by cited references. From a total of 131 references cited in promotional materials, sixty (46%) were incorrectly listed according to the International Committee of Medical Journal Editors. These references were inaccessible. Of the 71 references correctly cited, 49 (69%) were not available in any of the four major medical libraries in Buenos Aires and 8 were available in only two of the libraries. Twenty-two references were reviewed, and in twelve of these (54%), the objective of the research study concurred with the statement of the promotional printed material. Adverse reactions, warnings about drug interactions and contraindications were absent from all promotional printed material. It can be concluded that the promotional printed material distributed by the drug reps in Buenos Aires are biased and provide misinformation more often than not. We recommend that practicing physicians routinely disregard promotional printed material as a source of clinical information.

  16. The influence of Saccharomyces cerevisiae enzyme ratio on preparation virgin coconut oil for candidate in-house reference materials

    NASA Astrophysics Data System (ADS)

    Rohyami, Yuli; Anjani, Rafika Debby; Purwanti, Napthalina Putri

    2017-03-01

    Virgin coconut oil is an excellent product which has result of oil processing business opportunities in the international market. Standardization of virgin coconut oil necessary to satisfy the requirements industry needs. This research is expected as procedure preparation of reference materials. Preparation of virgin coconut oil by Sacharomycescerevisiaeenzyme. Based on the results of this study concluded that the ratio of Saccharomyces cerevisiae can affect the yield of virgin coconut oil produced. The preparation of virgin coconut oil enzymatically using a variety of mass ratio of 0.001 to 0.006% is obtained yield average of 12.40%. The optimum separation of virgin coconut oil on the use of enzymes with a mass ratio of 0.002%. The average water content at a ratio of 0.002% is 0.04 % with a value of uncertainty is 0.005%. The average iodine number in virgin coconut oil produced is 2.4403 ± 0,1974 grams of iodine per 100 grams of oil and optimum iodine number is obtained from the manufacturing process virgin coconut oil with a ratio of 0.006% Saccharomyces cerevisiae. Sacharomycescerevisiae with a ratio of 0.002% results virgin coconut oil with acid number 0.3068 ± 0.1098%. The peroxide value of virgin coconut oil between 0.0108 ± 0.009 to 0.0114 ± 0015milli-equivalent per kilograms. Organoleptic test results and test chemical parameters can be used as the test data that can be developed in prototype preparation of candidate in-house reference material in the testing standards of quality virgin coconut oil.

  17. Round-robin 230Th– 234U age dating of bulk uranium for nuclear forensics

    DOE PAGES

    Gaffney, Amy M.; Hubert, Amélie; Kinman, William S.; ...

    2015-07-30

    We report that in an inter-laboratory measurement comparison study, four laboratories determined 230Th– 234U model ages of uranium certified reference material NBL U050 using isotope dilution mass spectrometry. The model dates determined by the participating laboratories range from 9 March 1956 to 19 October 1957, and are indistinguishable given the associated measurement uncertainties. These model ages are concordant with to slightly older than the known production age of NBL U050.

  18. Round-robin 230Th– 234U age dating of bulk uranium for nuclear forensics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gaffney, Amy M.; Hubert, Amélie; Kinman, William S.

    We report that in an inter-laboratory measurement comparison study, four laboratories determined 230Th– 234U model ages of uranium certified reference material NBL U050 using isotope dilution mass spectrometry. The model dates determined by the participating laboratories range from 9 March 1956 to 19 October 1957, and are indistinguishable given the associated measurement uncertainties. These model ages are concordant with to slightly older than the known production age of NBL U050.

  19. Biocidal packaging for pharmaceuticals, foods, and other perishables.

    PubMed

    Larson, Alyssa M; Klibanov, Alexander M

    2013-01-01

    Many consumer goods must be protected from bacterial and fungal colonization to ensure their integrity and safety. By making these items' packaging biocidal, the interior environment can be preserved from microbial spoilage without altering the products themselves. Herein we briefly review this concept, referred to as active packaging, and discuss existing methods for constructing active packaging systems. They are based on either packaging materials that release biocides or those that are themselves intrinsically biocidal (or biostatic), with numerous variations within each category.

  20. Real-time sonoelastography using an external reference material: test-retest reliability of healthy Achilles tendons.

    PubMed

    Schneebeli, Alessandro; Del Grande, Filippo; Vincenzo, Gabriele; Cescon, Corrado; Clijsen, Ron; Biordi, Fulvio; Barbero, Marco

    2016-08-01

    To establish the test-retest reliability of sonoelastography (SE) on healthy Achilles tendons in contracted and relaxed states using an external reference system. Forty-eight Achilles tendons from 24 healthy volunteers were assessed using ultrasound and real-time SE with an external reference material. Tendons were analyzed under relaxed and contracted conditions. Strain ratios between the tendons and the reference material were calculated. The intraclass correlation coefficient (ICC2.k) and Bland-Altman plot were used to assess test-retest reliability. The reliability of SE measurements under relaxed conditions ranged from high to very high, with an ICC2.k of 0.84 (95 % CI: 0.64-0.92) for reference material, 0.91 (95 % CI: 0.83-0.95) for Achilles tendons and 0.95 (95 % CI: 0.91-0.97) for Kager fat pads (KFP). The ICC2.k value for skin was 0.30 (95 % CI: -0.26 to 0.61). Reliability for measurements in the contracted state ranged from high to very high, with an ICC2.k of 0.93 (95 % CI: 0.87-0.96) for reference material, 0.72 (95 % CI: 0.50-0.84) for skin, 0.93 (95 % CI: 0.87-0.96) for Achilles tendons, and 0.81 (95 % CI: 0.66-0.89) for KFP. Reliability of the strain ratio (tendon/reference) under relaxed conditions was high with an ICC2.k of 0.87 (95 % CI: 0.75-0.93), and in the contracted state, it was very high with an ICC2.k of 0.94 (95 % CI: 0.90-0.97). Sonoelastography using an external reference material is a reliable and simple technique for the assessment of the elasticity of healthy Achilles tendons. The use of an external material as a reference, along with strain ratios, could provide a quantitative measure of elasticity.

  1. ALF: a strategy for identification of unauthorized GMOs in complex mixtures by a GW-NGS method and dedicated bioinformatics analysis.

    PubMed

    Košir, Alexandra Bogožalec; Arulandhu, Alfred J; Voorhuijzen, Marleen M; Xiao, Hongmei; Hagelaar, Rico; Staats, Martijn; Costessi, Adalberto; Žel, Jana; Kok, Esther J; Dijk, Jeroen P van

    2017-10-26

    The majority of feed products in industrialised countries contains materials derived from genetically modified organisms (GMOs). In parallel, the number of reports of unauthorised GMOs (UGMOs) is gradually increasing. There is a lack of specific detection methods for UGMOs, due to the absence of detailed sequence information and reference materials. In this research, an adapted genome walking approach was developed, called ALF: Amplification of Linearly-enriched Fragments. Coupling of ALF to NGS aims for simultaneous detection and identification of all GMOs, including UGMOs, in one sample, in a single analysis. The ALF approach was assessed on a mixture made of DNA extracts from four reference materials, in an uneven distribution, mimicking a real life situation. The complete insert and genomic flanking regions were known for three of the included GMO events, while for MON15985 only partial sequence information was available. Combined with a known organisation of elements, this GMO served as a model for a UGMO. We successfully identified sequences matching with this organisation of elements serving as proof of principle for ALF as new UGMO detection strategy. Additionally, this study provides a first outline of an automated, web-based analysis pipeline for identification of UGMOs containing known GM elements.

  2. 10 CFR 431.443 - Materials incorporated by reference.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... the date of the approval and a notice of any change in the material will be published in the Federal... 10 Energy 3 2014-01-01 2014-01-01 false Materials incorporated by reference. 431.443 Section 431... AND INDUSTRIAL EQUIPMENT Small Electric Motors Test Procedures § 431.443 Materials incorporated by...

  3. STANDARD REFERENCE MATERIALS FOR THE POLYMERS INDUSTRY.

    PubMed

    McDonough, Walter G; Orski, Sara V; Guttman, Charles M; Migler, Kalman D; Beers, Kathryn L

    2016-01-01

    The National Institute of Standards and Technology (NIST) provides science, industry, and government with a central source of well-characterized materials certified for chemical composition or for some chemical or physical property. These materials are designated Standard Reference Materials ® (SRMs) and are used to calibrate measuring instruments, to evaluate methods and systems, or to produce scientific data that can be referred readily to a common base. In this paper, we discuss the history of polymer based SRMs, their current status, and challenges and opportunities to develop new standards to address industrial measurement challenges.

  4. Microbial isoprenoid production: an example of green chemistry through metabolic engineering.

    PubMed

    Maury, Jérôme; Asadollahi, Mohammad A; Møller, Kasper; Clark, Anthony; Nielsen, Jens

    2005-01-01

    Saving energy, cost efficiency, producing less waste, improving the biodegradability of products, potential for producing novel and complex molecules with improved properties, and reducing the dependency on fossil fuels as raw materials are the main advantages of using biotechnological processes to produce chemicals. Such processes are often referred to as green chemistry or white biotechnology. Metabolic engineering, which permits the rational design of cell factories using directed genetic modifications, is an indispensable strategy for expanding green chemistry. In this chapter, the benefits of using metabolic engineering approaches for the development of green chemistry are illustrated by the recent advances in microbial production of isoprenoids, a diverse and important group of natural compounds with numerous existing and potential commercial applications. Accumulated knowledge on the metabolic pathways leading to the synthesis of the principal precursors of isoprenoids is reviewed, and recent investigations into isoprenoid production using engineered cell factories are described.

  5. Ocean services user needs assessment. Volume 1: Survey results, conclusions and recommendations

    NASA Technical Reports Server (NTRS)

    Montgomery, D. R.; Patton, R. J.; Mccandless, S. W.

    1984-01-01

    An interpretation of environmental information needs of marine users, derived from a direct contact survey of eight important sectors of the marine user community is presented. Findings of the survey and results and recommendations are reported. The findings consist of specific and quantized measurement and derived product needs for each sector and comparisons of these needs with current and planned NOAA data and services. The following supportive and reference material are examined: direct contact interviews with industry members, analyses of current NOAA data gathering and derived product capabilities, evaluations of new and emerging domestic and foreign satellite data gathering capabilities, and a special commercial fishing survey conducted by the Jet Propulsion Laboratory (JPL).

  6. Production of polyhydroxybutyrate in switchgrass

    DOEpatents

    Somleva, Mariya N.; Snell, Kristi D.; Beaulieu, Julie; Peoples, Oliver P.; Garrison, Bradley; Patterson, Nii

    2013-07-16

    Transgenic plants, plant material, and plant cells for synthesis of polyhydroxyalkanoates, preferably poly(3-hydroxybutyrate) (also referred to a as PHB) are provided. Preferred plants that can be genetically engineered to produce PHB include plants that do not normally produce storage products such as oils and carbohydrates, and plants that have a C.sub.4 NAD-malic enzyme photosynthetic pathway. Such plants also advantageously produce lignocellulosic biomass that can be converted into biofuels. An exemplary plant that can be genetically engineered to produce PHB and produce lignocellulosic biomass is switchgrass, Panicum virgatum L. A preferred cultivar of switchgrass is Alamo. Other suitable cultivars of switchgrass include but are not limited to Blackwell, Kanlow, Nebraska 28, Pathfinder, Cave-in-Rock, Shelter and Trailblazer.

  7. Safety Discrete Event Models for Holonic Cyclic Manufacturing Systems

    NASA Astrophysics Data System (ADS)

    Ciufudean, Calin; Filote, Constantin

    In this paper the expression “holonic cyclic manufacturing systems” refers to complex assembly/disassembly systems or fork/join systems, kanban systems, and in general, to any discrete event system that transforms raw material and/or components into products. Such a system is said to be cyclic if it provides the same sequence of products indefinitely. This paper considers the scheduling of holonic cyclic manufacturing systems and describes a new approach using Petri nets formalism. We propose an approach to frame the optimum schedule of holonic cyclic manufacturing systems in order to maximize the throughput while minimize the work in process. We also propose an algorithm to verify the optimum schedule.

  8. [Prohibited substances in cosmetics: prospect of the toxicity of acrylamide].

    PubMed

    Shen, Minxue; Sun, Zhenqiu; Shi, Jingcheng; Hu, Ming; Hu, Jingxuan; Liu, Yanhong

    2012-04-01

    Prohibited substances in cosmetics refer to substances which must not be among the raw material ingredients of cosmetic products. These substances are absorbed mostly through skin, as well as via lung and gastrointestinal tract. Polyacrylamide is ubiquitously used in industry and its decomposition residue acrylamide (ACR) easily finds its way into cosmetic products. ACR can either be oxidized to epoxide glycidamide or conjugated with glutathione, hemoglobin or DNA; ultimately it is excreted in urine. ACR causes neurotoxicity, reproductive toxicity and tumors in rodents. Occupational exposure to ACR causes neurotoxicity in humans; however, epidemiological evidence have not unambiguously answered the question of whether ACR exposure can increase cancer risk for humans.

  9. Transportation research synthesis : ADA compliance reference and training materials.

    DOT National Transportation Integrated Search

    2010-03-01

    Our findings are presented in three categories: Reference Materials, Training Materials and State DOT Current : Practices. Appendix A to this report contains an updated list of ADA contacts for all 50 states and the District of : Columbia, and Append...

  10. Carroll County Competency Based Teacher Certification Project. Librarian's Report.

    ERIC Educational Resources Information Center

    Coker, Homer; Coker, Joan G.

    Reference materials, slides, cassettes, books, pamphlets, materials from other states, and articles used in the Carroll County, Georgia, Competency Based Teacher Certification Project, 1973-74, are listed. Brief annotations are included for both the reference materials and articles. (MJM)

  11. Polyfluorinated substances in abiotic standard reference materials

    EPA Science Inventory

    The National Institute of Standards and Technology (NIST) has a wide range of Standard Reference Materials (SRMs) which have values assigned for legacy organic pollutants and toxic elements. Existing SRMs serve as homogenous materials that can be used for method development, meth...

  12. Achieving Excellence in Library Instruction.

    ERIC Educational Resources Information Center

    Gilbert, Betty; And Others

    The materials included in this document supporting library instruction are divided into two chapters. The first chapter contains bibliographies of instructional materials, professional periodicals, general reference tools, and religious reference tools. Throughout the bibliographies, the approximate cost of the materials is indicated by dollar…

  13. Cu determination in crude oil distillation products by atomic absorption and inductively coupled plasma mass spectrometry after analyte transfer to aqueous solution

    NASA Astrophysics Data System (ADS)

    Kowalewska, Zofia; Ruszczyńska, Anna; Bulska, Ewa

    2005-03-01

    Cu was determined in a wide range of petroleum products from crude oil distillation using flame atomic absorption spectrometry (FAAS), electrothermal atomic absorption spectrometry (ETAAS) and inductively coupled plasma mass spectrometry (ICP-MS). Different procedures of sample preparation were evaluated: (i) mineralization with sulfuric acid in an open system, (ii) mineralization in a closed microwave system, (iii) combustion in hydrogen-oxygen flame in the Wickbold's apparatus, (iv) matrix evaporation followed by acid dissolution, and (v) acidic extraction. All the above procedures led to the transfer of the analyte into an aqueous solution for the analytical measurement step. It was found that application of FAAS was limited to the analysis of the heaviest petroleum products of high Cu content. In ICP-MS, the use of internal reference method (with Rh or In as internal reference element) was required to eliminate the matrix effects in the analysis of extracts and the concentrated solutions of mineralized heavy petroleum products. The detection limits (in original samples) were equal to, respectively, 10, 86, 3.3, 0.9 and 0.4 ng g - 1 in procedures i-v with ETAAS detection and 10, 78, 1.1 and 0.5 ng g - 1 in procedures i-iii and v with ICP-MS detection. The procedures recommended here were validated by recovery experiments, certified reference materials analysis and comparison of results, obtained for a given sample, in different ways. The Cu content in the analyzed samples was: 50-110 ng g - 1 in crude oil, < 0.4-6 ng g - 1 in gasoline, < 0.5-2 ng g - 1 in atmospheric oil, < 6-100 ng g - 1 in heavy vacuum oil and 140-300 ng g - 1 in distillation residue.

  14. The characterization and certification of a quantitative reference material for Legionella detection and quantification by qPCR.

    PubMed

    Baume, M; Garrelly, L; Facon, J P; Bouton, S; Fraisse, P O; Yardin, C; Reyrolle, M; Jarraud, S

    2013-06-01

    The characterization and certification of a Legionella DNA quantitative reference material as a primary measurement standard for Legionella qPCR. Twelve laboratories participated in a collaborative certification campaign. A candidate reference DNA material was analysed through PCR-based limiting dilution assays (LDAs). The validated data were used to statistically assign both a reference value and an associated uncertainty to the reference material. This LDA method allowed for the direct quantification of the amount of Legionella DNA per tube in genomic units (GU) and the determination of the associated uncertainties. This method could be used for the certification of all types of microbiological standards for qPCR. The use of this primary standard will improve the accuracy of Legionella qPCR measurements and the overall consistency of these measurements among different laboratories. The extensive use of this certified reference material (CRM) has been integrated in the French standard NF T90-471 (April 2010) and in the ISO Technical Specification 12 869 (Anon 2012 International Standardisation Organisation) for validating qPCR methods and ensuring the reliability of these methods. © 2013 The Society for Applied Microbiology.

  15. Determination of Perfluorinated Alkyl Acid Concentrations in Biological Standard Reference Materials

    EPA Science Inventory

    Standard reference materials (SRMs) are homogeneous, well-characterized materials used to validate measurements and improve the quality of analytical data. The National Institute of Standards and Technology (NIST) has a wide range of SRMs that have mass fraction values assigned ...

  16. Building Trades. Block VIII. Interior Trim.

    ERIC Educational Resources Information Center

    Texas A and M Univ., College Station. Vocational Instructional Services.

    This curriculum for interior trim provides instructional materials for 18 informational and manipulative lessons. A list of 11 references precedes the course materials. The instructor's plan for each informational lesson begins by providing this information: subject, aim, required teaching aids, required materials, references, and prerequisite…

  17. 40 CFR 1048.810 - What materials does this part reference?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....org. Table 1 follows: Table 1 of § 1048.810—SAE Materials Document number and name Part 1048reference..., Switzerland or http://www.iso.org. Table 2 follows: Table 2 of § 1048.810—ISO Materials Document number and...

  18. 14 CFR 171.71 - Materials incorporated by reference.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Headquarters. An historical file of these materials is maintained at Headquarters, Federal Aviation... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Materials incorporated by reference. 171.71 Section 171.71 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION...

  19. 14 CFR 171.71 - Materials incorporated by reference.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Headquarters. An historical file of these materials is maintained at Headquarters, Federal Aviation... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Materials incorporated by reference. 171.71 Section 171.71 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION...

  20. 14 CFR 171.71 - Materials incorporated by reference.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Headquarters. An historical file of these materials is maintained at Headquarters, Federal Aviation... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Materials incorporated by reference. 171.71 Section 171.71 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION...

  1. 14 CFR 171.71 - Materials incorporated by reference.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Headquarters. An historical file of these materials is maintained at Headquarters, Federal Aviation... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Materials incorporated by reference. 171.71 Section 171.71 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION...

  2. 14 CFR 171.71 - Materials incorporated by reference.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Headquarters. An historical file of these materials is maintained at Headquarters, Federal Aviation... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Materials incorporated by reference. 171.71 Section 171.71 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION...

  3. Standard and reference materials for marine science. Third edition. Technical memo

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cantillo, A.Y.

    1992-08-01

    The third edition of the catalog of reference materials suited for use in marine science, originally compiled in 1986 for NOAA, IOC, and UNEP. The catalog lists close to 2,000 reference materials from sixteen producers and contains information about their proper use, sources, availability, and analyte concentrations. Indices are included for elements, isotopes, and organic compounds, as are cross references to CAS registry numbers, alternate names, and chemical structures of selected organic compounds. The catalog is being published independently by both NOAA and IOC/UNEP and is available from NOAA/NOS/ORCA in electronic form.

  4. Locating interfaces in vertically-layered materials and determining concentrations in mixed materials utilizing acoustic impedance measurements

    DOEpatents

    Langlois, Gary N.

    1983-09-13

    Measurement of the relative and actual value of acoustic characteristic impedances of an unknown substance, location of the interfaces of vertically-layered materials, and the determination of the concentration of a first material mixed in a second material. A highly damped ultrasonic pulse is transmitted into one side of a reference plate, such as a tank wall, where the other side of the reference plate is in physical contact with the medium to be measured. The amplitude of a return signal, which is the reflection of the transmitted pulse from the interface between the other side of the reference plate and the medium, is measured. The amplitude value indicates the acoustic characteristic impedance of the substance relative to that of the reference plate or relative to that of other tested materials. Discontinuities in amplitude with repeated measurements for various heights indicate the location of interfaces in vertically-layered materials. Standardization techniques permit the relative acoustic characteristic impedance of a substance to be converted to an actual value. Calibration techniques for mixtures permit the amplitude to be converted to the concentration of a first material mixed in a second material.

  5. Locating interfaces in vertically-layered materials and determining concentrations in mixed materials utilizing acoustic impedance measurements

    DOEpatents

    Langlois, G.N.

    1983-09-13

    Measurement of the relative and actual value of acoustic characteristic impedances of an unknown substance, location of the interfaces of vertically-layered materials, and the determination of the concentration of a first material mixed in a second material are disclosed. A highly damped ultrasonic pulse is transmitted into one side of a reference plate, such as a tank wall, where the other side of the reference plate is in physical contact with the medium to be measured. The amplitude of a return signal, which is the reflection of the transmitted pulse from the interface between the other side of the reference plate and the medium, is measured. The amplitude value indicates the acoustic characteristic impedance of the substance relative to that of the reference plate or relative to that of other tested materials. Discontinuities in amplitude with repeated measurements for various heights indicate the location of interfaces in vertically-layered materials. Standardization techniques permit the relative acoustic characteristic impedance of a substance to be converted to an actual value. Calibration techniques for mixtures permit the amplitude to be converted to the concentration of a first material mixed in a second material. 6 figs.

  6. Collaborative study for the establishment of the WHO 3(rd) International Standard for Endotoxin, the Ph. Eur. endotoxin biological reference preparation batch 5 and the USP Reference Standard for Endotoxin Lot H0K354.

    PubMed

    Findlay, L; Desai, T; Heath, A; Poole, S; Crivellone, M; Hauck, W; Ambrose, M; Morris, T; Daas, A; Rautmann, G; Buchheit, K H; Spieser, J M; Terao, E

    2015-01-01

    An international collaborative study was organised jointly by the World Health Organization (WHO)/National Institute for Biological Standards and Control (NIBSC), the United States Pharmacopeia (USP) and the European Directorate for the Quality of Medicines & HealthCare (EDQM/Council of Europe) for the establishment of harmonised replacement endotoxin standards for these 3 organisations. Thirty-five laboratories worldwide, including Official Medicines Control Laboratories (OMCLs) and manufacturers enrolled in the study. Three candidate preparations (10/178, 10/190 and 10/196) were produced with the same material and same formulation as the current reference standards with the objective of generating a new (3(rd)) International Standard (IS) with the same potency (10 000 IU/vial) as the current (2(nd)) IS, as well as new European Pharmacopoeia (Ph. Eur.). and USP standards. The suitability of the candidate preparations to act as the reference standard in assays for endotoxin performed according to compendial methods was evaluated. Their potency was calibrated against the WHO 2(nd) IS for Endotoxin (94/580). Gelation and photometric methods produced similar results for each of the candidate preparations. The overall potency estimates for the 3 batches were comparable. Given the intrinsic assay precision, the observed differences between the batches may be considered unimportant for the intended use of these materials. Overall, these results were in line with those generated for the establishment of the current preparations of reference standards. Accelerated degradation testing of vials stored at elevated temperatures supported the long-term stability of the 3 candidate preparations. It was agreed between the 3 organisations that batch 10/178 be shared between WHO and EDQM and that batches 10/190 and 10/196 be allocated to USP, with a common assigned value of 10 000 IU/vial. This value maintains the continuity of the global harmonisation of reference materials and unitage for the testing of endotoxins in parenteral pharmaceutical products. Based on the results of the collaborative study, batch 10/178 was established by the European Pharmacopoeia Commission as the Ph. Eur. Endotoxin Biological Reference Preparation (BRP) batch 5. The same batch was also established by the Expert Committee on Biological Standardisation (ECBS) of WHO as the WHO 3(rd) IS for Endotoxin. Batch 10/190 was adopted as the USP Endotoxin Reference Standard, lot H0K354 and vials from this same batch (10/190) will serve as the United States Food and Drug Administration (USFDA) Endotoxin Standard, EC-7.

  7. Preparation of canine C-reactive protein serum reference material: A feasibility study.

    PubMed

    Canalias, Francesca; Piñeiro, Matilde; Pato, Raquel; Peña, Raquel; Bosch, Lluís; Soler, Lourdes; García, Natalia; Lampreave, Fermín; Saco, Yolanda; Bassols, Anna

    2018-03-01

    The availability of a species-specific reference material is essential for the harmonization of results obtained in different laboratories by different methods. We describe the preparation of a canine C-reactive protein (cCRP) serum reference material containing purified cCRP stabilized in a serum matrix. The material can be used by manufacturers to assign values to their calibrator and control materials. The serum matrix was obtained using blood collected from healthy dogs, stabilized and submitted for a delipidation process. The reference material was prepared by diluting purified cCRP in the serum matrix containing 1.0 mol/L HEPES buffer, 3.0 mmol/L calcium chloride, 80,000 kUI/L aprotinin, and 1.0 mmol/L benzamidine hydrochloride monohydrate at a pH of 7.2, and dispensing (0.5 mL) the matrix into vials that were then frozen. The pilot batch of 200 vials was shown to be homogeneous and stable after a stability study at various temperatures and over a total time of 110 days. The prepared material was submitted to an assignment value study. Eight laboratories from different European countries participated by using the same reagents for an immunoturbidimetric method adapted for different analyzers. The obtained cCRP concentration in the reference material was 78.5 mg/L with an expanded uncertainty (k = 2) of 4.2 mg/L. Canine C-reactive protein serum reference material has been produced that allows harmonization of results obtained by different methods and different laboratories, thus reducing the possibility of errors and misunderstandings. © 2018 American Society for Veterinary Clinical Pathology.

  8. The influence of different referencing methods on the accuracy of δ(13) C value measurement of ethanol fuel by gas chromatography/combustion/isotope ratio mass spectrometry.

    PubMed

    Neves, Laura A; Rodrigues, Janaína M; Daroda, Romeu J; Silva, Paulo R M; Ferreira, Alexandre A; Aranda, Donato A G; Eberlin, Marcos N; Fasciotti, Maíra

    2015-11-15

    Brazil is the largest producer of sugar cane bioethanol in the world. Isotope ratio mass spectrometry (IRMS) is the technique of choice to certify the origin/raw materials for ethanol production, but the lack of certified reference materials (CRMs) for accurate measurements of δ(13) C values traceable to Vienna Pee Dee Belemnite (VPDB), the international zero point for (13) C/(12) C measurements, certified and compatible with gas chromatography (GC)/IRMS instruments may compromise the accuracy of δ(13) C determinations. We evaluated the influence of methods for the calibration and normalization of raw δ(13) C values of ethanol samples. Samples were analyzed by GC/C/IRMS using two different GC columns. Different substances were used as isotopic standards for the working gas calibration. The δ(13) C values obtained with the three methods of normalization were statistically compared with those obtained with elemental analyzer (EA)/IRMS, since the δ(13) C results obtained using EA are traceable to VPDB via the NBS 22 reference material. It was observed that both the isotopic reference material for CO2 calibration and the GC column have a major effect on the δ(13) C measurements, leading to a bias of almost 2-3 ‰ in the δ(13) C values. All three methods of normalization were equivalent in performance, enabling an improvement in the GC/C/IRMS accuracy, compared with the EA/IRMS reference values for the samples. All the methods of CO2 calibration, chromatography and normalization presented in this work demonstrated several sources of traceability and accuracy loss for the determination of δ(13) C values in ethanol fuel samples by GC/C/IRMS. This work has also shown the importance of using proper CRMs traceable to VPBD that should be compatible and certified using GC/C/IRMS, ideally in a wide range of δ(13) C values. This is important not only for bioethanol fuel samples, but also for many analytes commonly analyzed by IRMS. Copyright © 2015 John Wiley & Sons, Ltd.

  9. Bibliography for the Hospitality Industry.

    ERIC Educational Resources Information Center

    Nelson, Elizabeth A.

    This annotated bibliography is a sample collection of reference materials in the hospitality industry suitable for a small academic library. It is assumed that the library has a general reference collection. Publication dates range from 1992-96, with two publication dates in the 1980s. No periodicals are included. The 41 reference materials are…

  10. 49 CFR 511.53 - Appeal from initial decision.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... position taken on each question, with specific page references to the record and legal or other material... matters in the brief, with page references, and a table of cases (alphabetically arranged), textbooks, statutes, and other material cited, with page references thereto; (2) A concise statement of the case; (3...

  11. 49 CFR 511.53 - Appeal from initial decision.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... position taken on each question, with specific page references to the record and legal or other material... matters in the brief, with page references, and a table of cases (alphabetically arranged), textbooks, statutes, and other material cited, with page references thereto; (2) A concise statement of the case; (3...

  12. 49 CFR 511.53 - Appeal from initial decision.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... position taken on each question, with specific page references to the record and legal or other material... matters in the brief, with page references, and a table of cases (alphabetically arranged), textbooks, statutes, and other material cited, with page references thereto; (2) A concise statement of the case; (3...

  13. 40 CFR 91.6 - Reference materials.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... EMISSIONS FROM MARINE SPARK-IGNITION ENGINES General § 91.6 Reference materials. (a) Incorporation by... the Research Method Appendix A to Subpart D. ASTM D2700-92: Standard Test Method for Knock... 40 CFR part 91 reference SAE J1228/ISO 8665 November 1991 Small Craft-Marine Propulsion Engine and...

  14. 40 CFR 91.6 - Reference materials.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... EMISSIONS FROM MARINE SPARK-IGNITION ENGINES General § 91.6 Reference materials. (a) Incorporation by... the Research Method Appendix A to Subpart D. ASTM D2700-92: Standard Test Method for Knock... 40 CFR part 91 reference SAE J1228/ISO 8665 November 1991 Small Craft-Marine Propulsion Engine and...

  15. 40 CFR 91.6 - Reference materials.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... EMISSIONS FROM MARINE SPARK-IGNITION ENGINES General § 91.6 Reference materials. (a) Incorporation by... the Research Method Appendix A to Subpart D. ASTM D2700-92: Standard Test Method for Knock... 40 CFR part 91 reference SAE J1228/ISO 8665 November 1991 Small Craft-Marine Propulsion Engine and...

  16. Certification of elements in and use of standard reference material 3280 multivitamin/multielement tablets

    USDA-ARS?s Scientific Manuscript database

    Standard Reference Material (SRM) 3280 Multivitamin/Multielement Tablets was issued by the National Institute of Standards and Technology (NIST) in 2009 and has certified and reference mass fraction values for 13 vitamins, 26 elements, and 2 carotenoids. Elements were measured using two or more ana...

  17. Teaching about Asia: Professional Materials and Reference Books.

    ERIC Educational Resources Information Center

    Hantula, James N.

    This two-part document serves as a guide to basic materials on Asia. The first part provides the teacher of Asian studies with nonserial examples of pertinent professional materials and reference books in print since 1979. Criteria used in selecting the items are given and a brief comparison between materials available in 1969 and 1985 is made.…

  18. 40 CFR 1060.810 - What materials does this part reference?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    .... (a) ASTM material. Table 1 to this section lists material from the American Society for Testing and..., West Conshohocken, PA 19428 or http://www.astm.com. Table 1 follows: Table 1 to § 1060.810—ASTM Materials Document number and name Part 1060reference ASTM D471-06, Standard Test Method for Rubber Property...

  19. Biscayne aquifer drinking water (USGS45): a new isotopic reference material for δ2H and δ18O measurements of water.

    PubMed

    Lorenz, Jennifer M; Tarbox, Lauren; Buck, Bryan; Qi, Haiping; Coplen, Tyler B

    2014-10-15

    As a result of the scarcity of isotopic reference waters for daily use, a new secondary isotopic reference material for international distribution has been prepared from drinking water collected from the Biscayne aquifer in Ft. Lauderdale, Florida. This isotopic reference water was filtered, homogenized, loaded into glass ampoules, sealed with a torch, autoclaved to eliminate biological activity, and measured by dual-inlet isotope-ratio mass spectrometry. This reference material is available by the case of 144 glass ampoules containing either 4 mL or 5 mL of water in each ampoule. The δ(2)H and δ(18)O values of this reference material are -10.3 ± 0.4‰ and -2.238 ± 0.011‰, respectively, relative to VSMOW, on scales normalized such that the δ(2)H and δ(18)O values of SLAP reference water are, respectively, -428 and -55.5‰. Each uncertainty is an estimated expanded uncertainty (U = 2uc ) about the reference value that provides an interval that has about a 95% probability of encompassing the true value. This isotopic reference material, designated as USGS45, is intended as one of two isotopic reference waters for daily normalization of stable hydrogen and oxygen isotopic analysis of water with an isotope-ratio mass spectrometer or a laser absorption spectrometer. Published in 2014. This article is a U.S. Government work and is in the public domain in the USA. Published in 2014. This article is a U.S. Government work and is in the public domain in the USA.

  20. Combined Use of Shrinkage Reducing Admixture and CaO in Cement Based Materials

    NASA Astrophysics Data System (ADS)

    Tittarelli, Francesca; Giosuè, Chiara; Monosi, Saveria

    2017-10-01

    The combined addition of a Shrinkage-Reducing Admixture (SRA) with a CaO-based expansive agent (CaO) has been found to have a synergistic effect to improve the dimensional stability of cement based materials. In this work, aimed to further investigate the effect, mortar and self-compacting concrete specimens were prepared either without admixtures, as reference, or with SRA alone and/or CaO. Their performance was compared in terms of compressive strength and free shrinkage measurements. Results showed that the synergistic effect in reducing shrinkage is confirmed in the specimens manufactured with SRA and CaO. In order to clarify this phenomenon, the effect of SRA on the hydration of CaO as well as cement was evaluated through different techniques. The obtained results show that SRA induces a finer microstructure of the CaO hydration products and a retarding effect on the microstructure development of cement based materials. A more deformable mortar or concrete, due to the delay in microstructure development by SRA, coupled with a finer microstructure of CaO hydration products could allow higher early expansion, which might contribute in contrasting better the successive drying shrinkage.

  1. Effect of different packaging materials containing poly-[2-(tert-butylamino) methylstyrene] on the growth of spoilage and pathogenic bacteria on fresh meat.

    PubMed

    Dohlen, S; Braun, C; Brodkorb, F; Fischer, B; Ilg, Y; Kalbfleisch, K; Lorenz, R; Kreyenschmidt, M; Kreyenschmidt, J

    2017-09-18

    The objective of this study was to investigate the effect of novel antimicrobial packaging materials containing poly-[2-(tertbutylamino) methylstyrene] (poly(TBAMS)) on the growth of typical spoilage and pathogenic bacteria present on meat. The antimicrobial activity of materials containing different poly(TBAMS) concentrations was determined by comparing the bacterial counts on reference and sample materials at different temperatures and times and in the presence of meat components. Storage tests with poultry fillets and veal cutlets were conducted with samples vacuum packaged in the reference foil and foil containing 10% poly(TBAMS). After specific time intervals, typical spoilage microorganisms, total viable count (TVC), sensory changes and pH value were analysed. The results of the different poly(TBAMS) containing packaging materials showed an increase of the antimicrobial activity with an increasing amount of poly(TBAMS) in the base polymer. A high antimicrobial activity against inoculum of spoilage and pathogenic organisms typical for meat products was detected of a multilayer foil containing 10% poly(TBAMS) in the inner layer after 24h at 7°C. Gram positive-bacteria were more sensitive to poly(TBAMS) foil than gram-negative bacteria. In storage tests however, over the entire storage, a significant effect of this poly(TBAMS) foil on microbial growth on chicken breast fillets and veal cutlets could not be identified. Poly(TBAMS) packaging materials showed very good antimicrobial properties against a wide range of bacteria. However, for a significant inhibition of microbial growth on fresh meat, a higher amount of poly(TBAMS) was necessary to prolong the shelf life of meat. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Developing Maritime Thematic Expressions on English Reading Materials Used In Indonesia: Junior High School Context

    NASA Astrophysics Data System (ADS)

    Syahdan; Lusandi, Budi

    2018-05-01

    Indonesia is a maritime country with the largest islands in the world covering more than seventeen thousands islands. This wealth should be wisely explored for all their advantages. Also, all parties should take responsibility to inherit values embedded in the wealth. This study is a Research and Development focusing at developing English worksheet materials in the theme of Maritime Thematic Expressions. Specifically, it aimed at identifying initial contents of the English worksheet, describing the development of worksheet materials and justifying contents of worksheet materials in facilitating the students’ needs in reading English materials. The flow of this R&D refers to Sugiono’s model that includes analyzing data, collecting data, designing materials, validating material, revising the material, piloting products, revising the material, piloting materials, revising the material and material development. The development of this material adjusted to the needs of syllabus and national strategic issues in maritime that were coined with students of Junior High School Terbuka Pekanbaru. The worsksheet development has been revised and validated by some experts of curriculum and linguistics. This material has also been piloted by the English teacher to determine of the students’ ability in comprehending the materials. Based on the results of this development, it can be concluded that the materials development were relevant with the standard competence and basic competence in syllabus of the students’ reading skill in Junior High School Terbuka Pekanbaru.

  3. Towards better process understanding: chemometrics and multivariate measurements in manufacturing of solid dosage forms.

    PubMed

    Matero, Sanni; van Den Berg, Frans; Poutiainen, Sami; Rantanen, Jukka; Pajander, Jari

    2013-05-01

    The manufacturing of tablets involves many unit operations that possess multivariate and complex characteristics. The interactions between the material characteristics and process related variation are presently not comprehensively analyzed due to univariate detection methods. As a consequence, current best practice to control a typical process is to not allow process-related factors to vary i.e. lock the production parameters. The problem related to the lack of sufficient process understanding is still there: the variation within process and material properties is an intrinsic feature and cannot be compensated for with constant process parameters. Instead, a more comprehensive approach based on the use of multivariate tools for investigating processes should be applied. In the pharmaceutical field these methods are referred to as Process Analytical Technology (PAT) tools that aim to achieve a thorough understanding and control over the production process. PAT includes the frames for measurement as well as data analyzes and controlling for in-depth understanding, leading to more consistent and safer drug products with less batch rejections. In the optimal situation, by applying these techniques, destructive end-product testing could be avoided. In this paper the most prominent multivariate data analysis measuring tools within tablet manufacturing and basic research on operations are reviewed. Copyright © 2013 Wiley Periodicals, Inc.

  4. Production and Comprehension of Time Reference in Korean Nonfluent Aphasia

    PubMed Central

    Lee, Jiyeon; Kwon, Miseon; Na, Hae Ri; Bastiaanse, Roelien; Thompson, Cynthia K.

    2015-01-01

    Objectives Individuals with nonfluent agrammatic aphasia show impaired production and comprehension of time reference via verbal morphology. However, cross-linguistic findings to date suggest inconsistent evidence as to whether tense processing in general is impaired or time reference to the past is selectively difficult in this population. This study examined production and comprehension of time reference via verb morphology in Korean-speaking individuals with nonfluent aphasia. Methods A group of 9 healthy controls and 8 individuals with nonfluent aphasia (5 for the production task) participated in the study. Sentence priming production and auditory sentence to picture matching tasks were used, parallel with the previous cross-linguistic experiments in English, Chinese, Turkish, and others. Results The participants with nonfluent aphasia showed different patterns of impairment in production and comprehension. In production, they were impaired in all time references with errors being dominated by substitution of incorrect time references and other morpho-phonologically well-formed errors, indicating a largely intact morphological affixation process. In comprehension, they showed selective impairment of the past, consistent with the cross-linguistic evidence from English, Chinese, Turkish, and others. Conclusion The findings suggest that interpretation of past time reference poses particular difficulty in nonfluent aphasia irrespective of typological characteristics of languages; however, in production, language-specific morpho-semantic functions of verbal morphology may play a significant role in selective breakdowns of time reference. PMID:26290861

  5. Production of bacterial cellulose and enzyme from waste fiber sludge

    PubMed Central

    2013-01-01

    Background Bacterial cellulose (BC) is a highly crystalline and mechanically stable nanopolymer, which has excellent potential as a material in many novel applications, especially if it can be produced in large amounts from an inexpensive feedstock. Waste fiber sludge, a residue with little or no value, originates from pulp mills and lignocellulosic biorefineries. A high cellulose and low lignin content contributes to making the fiber sludge suitable for bioconversion, even without a thermochemical pretreatment step. In this study, the possibility to combine production of BC and hydrolytic enzymes from fiber sludge was investigated. The BC was characterized using field-emission scanning electron microscopy and X-ray diffraction analysis, and its mechanical properties were investigated. Results Bacterial cellulose and enzymes were produced through sequential fermentations with the bacterium Gluconacetobacter xylinus and the filamentous fungus Trichoderma reesei. Fiber sludges from sulfate (SAFS) and sulfite (SIFS) processes were hydrolyzed enzymatically without prior thermochemical pretreatment and the resulting hydrolysates were used for BC production. The highest volumetric yields of BC from SAFS and SIFS were 11 and 10 g/L (DW), respectively. The BC yield on initial sugar in hydrolysate-based medium reached 0.3 g/g after seven days of cultivation. The tensile strength of wet BC from hydrolysate medium was about 0.04 MPa compared to about 0.03 MPa for BC from a glucose-based reference medium, while the crystallinity was slightly lower for BC from hydrolysate cultures. The spent hydrolysates were used for production of cellulase with T. reesei. The cellulase activity (CMCase activity) in spent SAFS and SIFS hydrolysates reached 5.2 U/mL (87 nkat/mL), which was similar to the activity level obtained in a reference medium containing equal amounts of reducing sugar. Conclusions It was shown that waste fiber sludge is a suitable raw material for production of bacterial cellulose and enzymes through sequential fermentation. The concept studied offers efficient utilization of the various components in fiber sludge hydrolysates and affords a possibility to combine production of two high value-added products using residual streams from pulp mills and biorefineries. Cellulase produced in this manner could tentatively be used to hydrolyze fresh fiber sludge to obtain medium suitable for production of BC in the same biorefinery. PMID:23414733

  6. A new basaltic glass microanalytical reference material for multiple techniques

    USGS Publications Warehouse

    Wilson, Steve; Koenig, Alan; Lowers, Heather

    2012-01-01

    The U.S. Geological Survey (USGS) has been producing reference materials since the 1950s. Over 50 materials have been developed to cover bulk rock, sediment, and soils for the geological community. These materials are used globally in geochemistry, environmental, and analytical laboratories that perform bulk chemistry and/or microanalysis for instrument calibration and quality assurance testing. To answer the growing demand for higher spatial resolution and sensitivity, there is a need to create a new generation of microanalytical reference materials suitable for a variety of techniques, such as scanning electron microscopy/X-ray spectrometry (SEM/EDS), electron probe microanalysis (EPMA), laser ablation inductively coupled mass spectrometry (LA-ICP-MS), and secondary ion mass spectrometry (SIMS). As such, the microanalytical reference material (MRM) needs to be stable under the beam, be homogeneous at scales of better than 10–25 micrometers for the major to ultra-trace element level, and contain all of the analytes (elements or isotopes) of interest. Previous development of basaltic glasses intended for LA-ICP-MS has resulted in a synthetic basaltic matrix series of glasses (USGS GS-series) and a natural basalt series of glasses (BCR-1G, BHVO-2G, and NKT-1G). These materials have been useful for the LA-ICP-MS community but were not originally intended for use by the electron or ion beam community. A material developed from start to finish with intended use in multiple microanalytical instruments would be useful for inter-laboratory and inter-instrument platform comparisons. This article summarizes the experiments undertaken to produce a basalt glass reference material suitable for distribution as a multiple-technique round robin material. The goal of the analytical work presented here is to demonstrate that the elemental homogeneity of the new glass is acceptable for its use as a reference material. Because the round robin exercise is still underway, only nominal compositional ranges for each element are given in the article.

  7. Bioavailability of paracetamol, phenylephrine hydrochloride and guaifenesin in a fixed-combination syrup versus an oral reference product.

    PubMed

    Janin, Annick; Monnet, Joelle

    2014-04-01

    The primary objective of this study was to compare the bioavailability of paracetamol, phenylephrine hydrochloride and guaifenesin in a new oral syrup with an established oral reference product. The secondary objective was to compare the safety of the new syrup and the reference product. This was a single-centre, open-label, randomized, reference-replicated, crossover study. Healthy adult volunteers received one dose of syrup and two separate doses of a reference oral liquid formulation in a randomized sequence over three study periods, with a washout interval of ≥ 7 days between study periods. Blood samples were taken regularly postdose and analysed for paracetamol, phenylephrine hydrochloride and guaifenesin concentrations; adverse events were recorded. This study enrolled 45 subjects. For paracetamol and guaifenesin, the syrup and reference product were considered to be bioequivalent. Bioequivalence was not shown for phenylephrine hydrochloride. All adverse events were mild or moderate, most of which were considered formulation related. The syrup did not reach bioequivalence with the reference product, as bioequivalence could not be shown for phenylephrine hydrochloride. This may be due to differences in the excipients between the two products. Both the syrup and the reference product had a good safety profile and were well tolerated.

  8. Compatibility of Elastomeric Seal Compounds with MIL-H-6083 and MIL-H- 46170 Hydraulic Fluid

    DTIC Science & Technology

    1990-06-01

    are also made with results obtained using NBR -L, a reference material cited in AMS 3217. 20. DISTRIBUTION/AVAILABILJTY OF ABSTRACT 21. ABSTRACT...Concurrent comparative studies were conducted using NBR -L, a standard reference compound cited in Aerospace Materials Specification (AMS) 3217. Volume...of a standard reference material such as NBR -L, cited in AMS 3217. Obviously, requirements for fluids and for seals are both dictated by the needs of

  9. Field Demonstration and Validation of a New Device for Measuring Water and Solute Fluxes at CFB Borden

    DTIC Science & Technology

    2006-11-01

    All Quality Control Reference Materials are acquired only from authorized vendors or sources commonly used by U.S. EPA Regional Laboratories...Institue of Standards and Testing (NITS) Standard Reference Materials (SRM) or to the U.S. EPA Reference Standards. Working Standards The commercial...contaminants from clothing or equipment by blowing, shaking or any other means that may disperse material into the air is prohibited. 7.1.3. All disposable

  10. Homogeneity study of a corn flour laboratory reference material candidate for inorganic analysis.

    PubMed

    Dos Santos, Ana Maria Pinto; Dos Santos, Liz Oliveira; Brandao, Geovani Cardoso; Leao, Danilo Junqueira; Bernedo, Alfredo Victor Bellido; Lopes, Ricardo Tadeu; Lemos, Valfredo Azevedo

    2015-07-01

    In this work, a homogeneity study of a corn flour reference material candidate for inorganic analysis is presented. Seven kilograms of corn flour were used to prepare the material, which was distributed among 100 bottles. The elements Ca, K, Mg, P, Zn, Cu, Fe, Mn and Mo were quantified by inductively coupled plasma optical emission spectrometry (ICP OES) after acid digestion procedure. The method accuracy was confirmed by analyzing the rice flour certified reference material, NIST 1568a. All results were evaluated by analysis of variance (ANOVA) and principal component analysis (PCA). In the study, a sample mass of 400mg was established as the minimum mass required for analysis, according to the PCA. The between-bottle test was performed by analyzing 9 bottles of the material. Subsamples of a single bottle were analyzed for the within-bottle test. No significant differences were observed for the results obtained through the application of both statistical methods. This fact demonstrates that the material is homogeneous for use as a laboratory reference material. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morita, M.

    Chlorinated benzenes are composed of twelve chemical species: one mono-, three di-, three tri-, three tetra-, one penta-, and one hexachlorobenzene. Most of these are not only important intermediates for various kinds of chemicals but are also extensively employed for various applications singly or in combination. For example, 1,4-dichlorobenzene is used chiefly against termites in soil; trichlorobenzenes are used as solvents for pesticides and also as heat transfer agents with PCBs; the mixture of trichlorobenzene and tetrachlorobenzene is applied in controlling shellfish predators; and hexachlorobenzene is applied to wheat as a fungicide in some countries and as an additive tomore » rubber products. The annual production (1973) of monochlorobenzene, 1,2-dichlorobenzene, and 1,4-dichlorobenzene in Japan was about 23,000, 9000, and 20,000, tons, respectively. Production volumes of other chlorinated benzenes are not well known but are assumed to be smaller than those of the above three compounds. The total annual production of chlorinated benzenes far surpasses the peak production of PCBs (7000 tons/year) which are known as a ubiquitous pollutant in this country. Since chlorinated benzenes have a chemical structure and properties similar to those of PCBs and PCTs, it seemed necessary to direct our attention to environmental contamination by these materials. The present paper describes only the occurrence and the fate of these materials. Toxicity and biological impact are not referred to here.« less

  12. Environmental aspects and renewable energy sources in the production of construction aggregate

    NASA Astrophysics Data System (ADS)

    Skrzypczak, Izabela; Kokoszka, Wanda; Buda-Ożóg, Lidia; Kogut, Janusz; Słowik, Marta

    2017-11-01

    The main activity of open pit mining of aggregates are aggregates' exploitation of natural mineral deposits and its modification in order to obtain high-quality aggregates. The development of aggregate production is conditioned by a number of factors. The most important are: documented material resources, mining and manufacturing capabilities, the need of environmental protection (environmental aspects), the subordination of the plan of spatial development, formal and legal issues, as well as economic and financial aspects. While identifying and assessing the environmental impacts of manufacturing aggregates one may distinguish those environmental aspects that have or may have the greatest magnitude of the impact on the environment as a result of industrial activities. Manufacturers producing aggregates located in the areas covered by the special environmental protection require extra diligence in the conduct of mining activities for preservation of natural resources. The article discusses some main environmental aspects of the production of construction aggregates on the example of one of the largest producers of this material in Subcarpathian province of Poland. Environmental protection in production of aggregates may refer to four aspects: the use of natural resources, having excluded land from agriculture and forestry, land reclamation after exploitation, and use of energy from renewable energy sources. The economic and environmental impact of production volume of aggregates is evaluated by the index information capacity method and the method of graphs.

  13. Interlaboratory comparison of reference materials for nitrogen-isotope-ratio measurements

    USGS Publications Warehouse

    Böhlke, John Karl; Coplen, Tyler B.

    1995-01-01

    Aliquots of seven different reference materials were distributed for an interlaboratory comparison of stable nitrogen-isotope-ratio measurements. Results from 15 laboratories were compiled and evaluated selectively to yield provisional values of 515N for each material, i, with respect to atmospheric N2 (o1SN,7air). The 515N values reported by the different laboratories are correlated in such a way that some of the major discrepancies may be removed by normalization (/. e., by altering the length of the ô N scale for each laboratory by an amount defined by local measurements of reference materials with extreme values).

  14. ALT-114 and ALT-118 Alternative Approaches to NIST ...

    EPA Pesticide Factsheets

    In 2016, US EPA approved two separate alternatives (ALT 114 and ALT 118) for the preparation and certification of Hydrogen Chloride (HCl) and Mercury (Hg) cylinder reference gas standards that can serve as EPA Protocol gases where EPA Protocol are required, but unavailable. The alternatives were necessary due to the unavailability of NIST reference materials (SRM, NTRM, CRM or RGM) or VSL reference materials (VSL PRM or VSL CRM), reference materials identified in EPA’s Green Book as necessary to establish the traceability of EPA protocol gases. ALT 114 and ALT 118 provides a pathway for gas vendors to prepare and certify traceable gas cylinder standards for use in certifying Hg and HCl CEMS. In this presentation, EPA will describe the mechanics and requirements of the performance-based approach, provide an update on the availability of these gas standards and also discuss the potential for producing and certifying gas standards for other compounds using this approach. This presentation discusses the importance of NIST-traceable reference gases relative to regulatory source compliance emissions monitoring. Specifically this presentation discusses 2 new approaches for making necessary reference gases available in the absence of NIST reference materials. Moreover, these approaches provide an alternative approach to rapidly make available new reference gases for additional HAPS regulatory compliance emissions measurement and monitoring.

  15. Microwave-assisted wet digestion with H2O2 at high temperature and pressure using single reaction chamber for elemental determination in milk powder by ICP-OES and ICP-MS.

    PubMed

    Muller, Edson I; Souza, Juliana P; Muller, Cristiano C; Muller, Aline L H; Mello, Paola A; Bizzi, Cezar A

    2016-08-15

    In this work a green digestion method which only used H2O2 as an oxidant and high temperature and pressure in the single reaction chamber system (SRC-UltraWave™) was applied for subsequent elemental determination by inductively coupled plasma-based techniques. Milk powder was chosen to demonstrate the feasibility and advantages of the proposed method. Samples masses up to 500mg were efficiently digested, and the determination of Ca, Fe, K, Mg and Na was performed by inductively coupled plasma optical emission spectrometry (ICP-OES), while trace elements (B, Ba, Cd, Cu, Mn, Mo, Pb, Sr and Zn) were determined by inductively coupled plasma mass spectrometry (ICP-MS). Residual carbon (RC) lower than 918mgL(-1) of C was obtained for digests which contributed to minimizing interferences in determination by ICP-OES and ICP-MS. Accuracy was evaluated using certified reference materials NIST 1549 (non-fat milk powder certified reference material) and NIST 8435 (whole milk powder reference material). The results obtained by the proposed method were in agreement with the certified reference values (t-test, 95% confidence level). In addition, no significant difference was observed between results obtained by the proposed method and conventional wet digestion using concentrated HNO3. As digestion was performed without using any kind of acid, the characteristics of final digests were in agreement with green chemistry principles when compared to digests obtained using conventional wet digestion method with concentrated HNO3. Additionally, H2O2 digests were more suitable for subsequent analysis by ICP-based techniques due to of water being the main product of organic matrix oxidation. The proposed method was suitable for quality control of major components and trace elements present in milk powder in consonance with green sample preparation. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Fraud Education for Accounting Students.

    ERIC Educational Resources Information Center

    Peterson, Bonita K.

    2003-01-01

    Reports that limited fraud education takes place in accounting due to a crowded curriculum and misunderstanding of the extent of fraud. Suggests ways to develop content on the topic and provides a list of teaching materials (textbooks, workbooks, trade books, case materials, videos, and reference materials). (Contains 16 references.) (SK)

  17. Effects of materials containing antimicrobial compounds on food hygiene.

    PubMed

    Møretrø, Trond; Langsrud, Solveig

    2011-07-01

    Surfaces with microorganisms may transfer unwanted microorganisms to food through cross-contamination during processing and preparation. A high hygienic status of surfaces that come in contact with food is important in order to reduce the risk of cross-contamination. During the last decade, products containing antimicrobial compounds, such as cutting boards, knives, countertops, kitchen utensils, refrigerators, and conveyor belts, have been introduced to the market, claiming hygienic effects. Such products are often referred to as "treated articles." Here we review various aspects related to treated articles intended for use during preparation and processing of food. Regulatory issues and methods to assess antibacterial effects are covered. Different concepts for treated articles as well as their antibacterial activity are reviewed. The effects of products with antimicrobials on food hygiene and safety are discussed. Copyright ©, International Association for Food Protection

  18. Dielectric Spectroscopy in Biomaterials: Agrophysics

    PubMed Central

    El Khaled, Dalia; Castellano, Nuria N.; Gázquez, Jose A.; Perea-Moreno, Alberto-Jesus; Manzano-Agugliaro, Francisco

    2016-01-01

    Being dependent on temperature and frequency, dielectric properties are related to various types of food. Predicting multiple physical characteristics of agri-food products has been the main objective of non-destructive assessment possibilities executed in many studies on horticultural products and food materials. This review manipulates the basic fundamentals of dielectric properties with their concepts and principles. The different factors affecting the behavior of dielectric properties have been dissected, and applications executed on different products seeking the characterization of a diversity of chemical and physical properties are all pointed out and referenced with their conclusions. Throughout the review, a detailed description of the various adopted measurement techniques and the mostly popular equipment are presented. This compiled review serves in coming out with an updated reference for the dielectric properties of spectroscopy that are applied in the agrophysics field. PMID:28773438

  19. Android-assisted physics mobile learning to improve senior high school students' divergent thinking skills and physics HOTS

    NASA Astrophysics Data System (ADS)

    Mardiana, Nana; Kuswanto, Heru

    2017-08-01

    The aims of the research concerned here were to reveal (1) the characteristics of Android-assisted PML (physics mobile learning) to improve SMA (sekolah menengah atas, Indonesian senior high school) students' divergent thinking skills and physics HOTS (higher order thinking skills); (2) the feasibility of the Android-assisted PML; and (3) the influence of using the Android-assisted PML on improvement in SMA students' divergent thinking skills and physics HOTS. The7 research was of the R&D (research and development) type, adapted from theBorg-&-Gall development model. The research data were analyzed by means of MANOVA with the significance level of 5%. The results are as follows. (1) The product of the development, a learning media in software form with the android package(apk) format, is named PML (to refer to Physics Mobile Learning), which has such characterictics as being operable with use of Android devicesand being very good in quality in the aspect oflearning, material, software technology, and audiovisual appearance. 2) The developed learning media referred to as PML is appropriate for learning activity according to evaluation by a material expert, a media expert, peer reviewers, and physics teachers as well as according to results of students' tryouts. (3) The use of the Android-assisted PML media product could improve SMA students' divergent thinking skillsand physics HOTS with the respective high-category gain scores of 0.701 and 0.759.

  20. DNA extraction techniques compared for accurate detection of genetically modified organisms (GMOs) in maize food and feed products.

    PubMed

    Turkec, Aydin; Kazan, Hande; Karacanli, Burçin; Lucas, Stuart J

    2015-08-01

    In this paper, DNA extraction methods have been evaluated to detect the presence of genetically modified organisms (GMOs) in maize food and feed products commercialised in Turkey. All the extraction methods tested performed well for the majority of maize foods and feed products analysed. However, the highest DNA content was achieved by the Wizard, Genespin or the CTAB method, all of which produced optimal DNA yield and purity for different maize food and feed products. The samples were then screened for the presence of GM elements, along with certified reference materials. Of the food and feed samples, 8 % tested positive for the presence of one GM element (NOS terminator), of which half (4 % of the total) also contained a second element (the Cauliflower Mosaic Virus 35S promoter). The results obtained herein clearly demonstrate the presence of GM maize in the Turkish market, and that the Foodproof GMO Screening Kit provides reliable screening of maize food and feed products.

  1. Use of similarity scoring in the development of oral solid dosage forms.

    PubMed

    Ferreira, Ana P; Olusanmi, Dolapo; Sprockel, Omar; Abebe, Admassu; Nikfar, Faranak; Tobyn, Mike

    2016-12-05

    In the oral solid dosage form space, material physical properties have a strong impact on the behaviour of the formulation during processing. The ability to identify materials with similar characteristics (and thus expected to exhibit similar behaviour) within the company's portfolio can help accelerate drug development by enabling early assessment and prediction of potential challenges associated with the powder properties of a new active pharmaceutical ingredient. Such developments will aid the production of robust dosage forms, in an efficient manner. Similarity scoring metrics are widely used in a number of scientific fields. This study proposes a practical implementation of this methodology within pharmaceutical development. The developed similarity metrics is based on the Mahalanobis distance. Scanning electron microscopy was used to confirm morphological similarity between the reference material and the closest matches identified by the metrics proposed. The results show that the metrics proposed are able to successfully identify material with similar physical properties. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Acoustic imaging microscope

    DOEpatents

    Deason, Vance A.; Telschow, Kenneth L.

    2006-10-17

    An imaging system includes: an object wavefront source and an optical microscope objective all positioned to direct an object wavefront onto an area of a vibrating subject surface encompassed by a field of view of the microscope objective, and to direct a modulated object wavefront reflected from the encompassed surface area through a photorefractive material; and a reference wavefront source and at least one phase modulator all positioned to direct a reference wavefront through the phase modulator and to direct a modulated reference wavefront from the phase modulator through the photorefractive material to interfere with the modulated object wavefront. The photorefractive material has a composition and a position such that interference of the modulated object wavefront and modulated reference wavefront occurs within the photorefractive material, providing a full-field, real-time image signal of the encompassed surface area.

  3. Aspects of the mechanisms of smoke generation by burning materials

    NASA Technical Reports Server (NTRS)

    Bankston, C. P.; Zinn, B. T.; Browner, R. F.; Powell, E. A.

    1981-01-01

    An investigation of smoke generation during the burning of natural and synthetic solid materials (relevant to fire safety problems), under simulated fire conditions, is presented. Smoke formation mechanisms, including flaming and nonflaming combustion, are reviewed, and the complex physical, chemical, and electrical processes, important in smoke particulate production, are identified. With reference to the smoke formation mechanisms, measured experimental data are discussed, and include effects of ventilation gas temperature, dependence on material composition, and chemical analysis of smoke particulates. Significant differences in smoke characteristics are observed between flaming and nonflaming conditions, which is attributed to specific differences in controlling mechanisms and resultant ways leading to particulate formation. The effects of polymer substrate properties and effects of additives for a given substrate on smoke properties are also discussed in terms of basic processes. It is shown that many of the measured trends can be interpreted by considering postulated mechanisms of particulate formation.

  4. Measuring Thermal Conductivity at LH2 Temperatures

    NASA Technical Reports Server (NTRS)

    Selvidge, Shawn; Watwood, Michael C.

    2004-01-01

    For many years, the National Institute of Standards and Technology (NIST) produced reference materials for materials testing. One such reference material was intended for use with a guarded hot plate apparatus designed to meet the requirements of ASTM C177-97, "Standard Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded-Hot-Plate Apparatus." This apparatus can be used to test materials in various gaseous environments from atmospheric pressure to a vacuum. It allows the thermal transmission properties of insulating materials to be measured from just above ambient temperature down to temperatures below liquid hydrogen. However, NIST did not generate data below 77 K temperature for the reference material in question. This paper describes a test method used at NASA's Marshall Space Flight Center (MSFC) to optimize thermal conductivity measurements during the development of thermal protection systems. The test method extends the usability range of this reference material by generating data at temperatures lower than 77 K. Information provided by this test is discussed, as are the capabilities of the MSFC Hydrogen Test Facility, where advanced methods for materials testing are routinely developed and optimized in support of aerospace applications.

  5. Reinforced silver-embedded silica matrix from the cheap silica source for the controlled release of silver ions

    NASA Astrophysics Data System (ADS)

    Hilonga, A.; Kim, J. K.; Sarawade, P. B.; Kim, H. T.

    2009-07-01

    In this study, a reinforced silver-embedded silica matrix was designed by utilizing the interaction between the [AlO 4] - tetrahedral and the Ag + in sol-gel process using sodium silicate as a silica precursor. The Ag + mole ratio in each sample was significantly varied to examine the influence of silver concentration on the properties of the final product. Aluminium ions were added to reinforce and improve the chemical durability of silver-embedded silica. A templated sample at Al/Ag = 1 atomic ratio was also synthesized to attempt a possibility of controlling porosity of the final product. Also, a sample neither embedded with silver nor templated was synthesized and characterized to serve as reference. The material at Al/Ag = 1 was found to have a desirable properties, compared to its counterparts, before and even after calcination up to 1000 °C. The results demonstrate that materials with desirable properties can be obtained by this unprecedented method while utilizing sodium silicate, which is relatively cheap, as a silica precursor. This may significantly boost the industrial production of the silver-embedded silicas for various applications.

  6. Review of Manganese Processing for Production of TRIP/TWIP Steels, Part 1: Current Practice and Processing Fundamentals

    NASA Astrophysics Data System (ADS)

    Elliott, R.; Coley, K.; Mostaghel, S.; Barati, M.

    2018-02-01

    The increasing demand for high-performance steel alloys has led to development of transformation-induced plasticity (TRIP) and twinning-induced plasticity (TWIP) alloys over the past three decades. These alloys offer exceptional combinations of high tensile strength and ductility. Thus, the mechanical behavior of these alloys has been a subject of significant work in recent years. However, the challenge of economically providing Mn in the quantity and purity required by these alloys has received considerably less attention. To enable commercial implementation of ultrahigh-Mn alloys, it is desirable to lower the high material costs associated with their production. Therefore, the present work reviews Mn processing routes in the context of the chemical requirements of these alloys. The aim of this review is to assess the current state of the art regarding reduction of manganese ores and provide a comprehensive reference for researchers working to mitigate material processing costs associated with Mn production. The review is presented in two parts: Part 1 introduces TRIP and TWIP alloys, current industrial practice, and pertinent thermodynamic fundamentals; Part 2 addresses available literature regarding reduction of Mn ores and oxides, and seeks to identify opportunities for future process development.

  7. Toward Worldwide Hepcidin Assay Harmonization: Identification of a Commutable Secondary Reference Material.

    PubMed

    van der Vorm, Lisa N; Hendriks, Jan C M; Laarakkers, Coby M; Klaver, Siem; Armitage, Andrew E; Bamberg, Alison; Geurts-Moespot, Anneke J; Girelli, Domenico; Herkert, Matthias; Itkonen, Outi; Konrad, Robert J; Tomosugi, Naohisa; Westerman, Mark; Bansal, Sukhvinder S; Campostrini, Natascia; Drakesmith, Hal; Fillet, Marianne; Olbina, Gordana; Pasricha, Sant-Rayn; Pitts, Kelly R; Sloan, John H; Tagliaro, Franco; Weykamp, Cas W; Swinkels, Dorine W

    2016-07-01

    Absolute plasma hepcidin concentrations measured by various procedures differ substantially, complicating interpretation of results and rendering reference intervals method dependent. We investigated the degree of equivalence achievable by harmonization and the identification of a commutable secondary reference material to accomplish this goal. We applied technical procedures to achieve harmonization developed by the Consortium for Harmonization of Clinical Laboratory Results. Eleven plasma hepcidin measurement procedures (5 mass spectrometry based and 6 immunochemical based) quantified native individual plasma samples (n = 32) and native plasma pools (n = 8) to assess analytical performance and current and achievable equivalence. In addition, 8 types of candidate reference materials (3 concentrations each, n = 24) were assessed for their suitability, most notably in terms of commutability, to serve as secondary reference material. Absolute hepcidin values and reproducibility (intrameasurement procedure CVs 2.9%-8.7%) differed substantially between measurement procedures, but all were linear and correlated well. The current equivalence (intermeasurement procedure CV 28.6%) between the methods was mainly attributable to differences in calibration and could thus be improved by harmonization with a common calibrator. Linear regression analysis and standardized residuals showed that a candidate reference material consisting of native lyophilized plasma with cryolyoprotectant was commutable for all measurement procedures. Mathematically simulated harmonization with this calibrator resulted in a maximum achievable equivalence of 7.7%. The secondary reference material identified in this study has the potential to substantially improve equivalence between hepcidin measurement procedures and contributes to the establishment of a traceability chain that will ultimately allow standardization of hepcidin measurement results. © 2016 American Association for Clinical Chemistry.

  8. Quality requirements for allergen extracts and allergoids for allergen immunotherapy.

    PubMed

    Zimmer, J; Bonertz, A; Vieths, S

    2017-12-01

    All allergen products for allergen immunotherapy currently marketed in the European Union are pharmaceutical preparations derived from allergen-containing source materials like pollens, mites and moulds. Especially this natural origin results in particular demands for the regulatory requirements governing allergen products. Furthermore, the development of regulatory requirements is complicated by the so far missing universal link between certain quality parameters, in particular biological potency, on the one hand and clinical efficacy on the other hand. As a consequence, each allergen product for specific immunotherapy has to be assessed individually for its quality, safety and efficacy. At the same time, biological potency of allergen products is most commonly determined using IgE inhibition assays based on human sera relative to product-specific in house references, ruling out full comparability of products from different manufacturers. This review article aims to summarize the current quality requirements for allergen products including the special requirements implemented for control of chemically modified allergen extracts (allergoids). Copyright © 2017 SEICAP. Published by Elsevier España, S.L.U. All rights reserved.

  9. Hydrothermal synthesis of 4ZnO·B2O3·H2O/RGO hybrid material and its flame retardant behavior in flexible PVC and magnesium hydroxide composites

    NASA Astrophysics Data System (ADS)

    Zhang, Zhifan; Wu, Weihong; Zhang, Mengjiao; Qu, Jiamin; Shi, Lin; Qu, Hongqiang; Xu, Jianzhong

    2017-12-01

    As a novel and efficient halogen-free composite flame retardant, zinc borate (4ZnO·B2O3·H2O)/reduction graphene oxide (RGO) hybrid material (ZB/RGO) was designed and synthesized using a facile route involving nano-engineering. The unique structure and composition of ZB/RGO were efficaciously confirmed by XRD, FTIR, SEM, TEM, and TG. The incorporation of 7.71 wt% ZB/RGO could significantly enhance the synergistic effect with Mg(OH)2 (MH) when mixed with poly(vinyl chloride) (PVC) as a flame retardant and smoke suppressant, as evaluated by limited oxygen index (LOI), microscale combustion calorimetry (MCC), and a cone calorimetry test (CCT) and compared with PVC, PVC/ZB, PVC/MH, and PVC/ZB/MH blends. The PVC/ZB/RGO/MH formulation could achieve an LOI value of 29.5% (24% higher than neat PVC). More importantly, the heat release rate (HRR), peak heat release rate (PHRR), smoke production rate (SPR), perk smoke production rate (PSPR), total smoke production (TSP), and mass amount loss (MAL) were considerably reduced in CCT, especially the PHRR, TSP, and MAL values for PVC/ZB/RGO/MH blends were reduced to 35%, 34%, and 15%, respectively. This study showed that the design of the novel material might provide a reference for the future development of halogen-free flame retardants consisting of inorganic salt and carbon material, which exhibit excellent flame retardant and smoke suppressant behavior.

  10. 40 CFR 1060.810 - What materials does this part reference?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) AIR POLLUTION CONTROLS CONTROL OF EVAPORATIVE EMISSIONS FROM NEW AND IN-USE NONROAD AND STATIONARY... Speciation, December 2003 1060.801 (c) California Air Resources Board material. Table 3 to this section lists material from the California Air Resources Board that we have incorporated by reference. The first column...

  11. 40 CFR 1060.810 - What materials does this part reference?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) AIR POLLUTION CONTROLS CONTROL OF EVAPORATIVE EMISSIONS FROM NEW AND IN-USE NONROAD AND STATIONARY... Speciation, December 2003 1060.801 (c) California Air Resources Board material. Table 3 to this section lists material from the California Air Resources Board that we have incorporated by reference. The first column...

  12. 40 CFR 1060.810 - What materials does this part reference?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) AIR POLLUTION CONTROLS CONTROL OF EVAPORATIVE EMISSIONS FROM NEW AND IN-USE NONROAD AND STATIONARY... Speciation, December 2003 1060.801 (c) California Air Resources Board material. Table 3 to this section lists material from the California Air Resources Board that we have incorporated by reference. The first column...

  13. Military aircraft and missile technology at the Langley Research Center: A selected bibliography

    NASA Technical Reports Server (NTRS)

    Maddalon, D. V.

    1980-01-01

    A compilation of reference material is presented on the Langley Research Center's efforts in developing advanced military aircraft and missile technology over the past twenty years. Reference material includes research made in aerodynamics, performance, stability, control, stall-spin, propulsion integration, flutter, materials, and structures.

  14. Field Demonstration and Validation of a New Device for Measuring Water and Solute Fluxes at Naval Base Ventura County (NBVC), Port Hueneme, CA

    DTIC Science & Technology

    2006-07-01

    All Quality Control Reference Materials are acquired only from authorized vendors or sources commonly used by U.S. EPA Regional Laboratories...are traceable to the National Institue of Standards and Testing (NITS) Standard Reference Materials (SRM) or to the U.S. EPA Reference Standards... clothing or equipment by blowing, shaking or any other means that may disperse material into the air is prohibited. 7.1.3. All disposable personal

  15. Type of Evidence Behind Point-of-Care Clinical Information Products: A Bibliometric Analysis

    PubMed Central

    2011-01-01

    Background Point-of-care (POC) products are widely used as information reference tools in the clinical setting. Although usability, scope of coverage, ability to answer clinical questions, and impact on health outcomes have been studied, no comparative analysis of the characteristics of the references, the evidence for the content, in POC products is available. Objective The objective of this study was to compare the type of evidence behind five POC clinical information products. Methods This study is a comparative bibliometric analysis of references cited in monographs in POC products. Five commonly used products served as subjects for the study: ACP PIER, Clinical Evidence, DynaMed, FirstCONSULT, and UpToDate. The four clinical topics examined to identify content in the products were asthma, hypertension, hyperlipidemia, and carbon monoxide poisoning. Four indicators were measured: distribution of citations, type of evidence, product currency, and citation overlap. The type of evidence was determined based primarily on the publication type found in the MEDLINE bibliographic record, as well as the Medical Subject Headings (MeSH), both assigned by the US National Library of Medicine. MeSH is the controlled vocabulary used for indexing articles in MEDLINE/PubMed. Results FirstCONSULT had the greatest proportion of references with higher levels of evidence publication types such as systematic review and randomized controlled trial (137/153, 89.5%), although it contained the lowest total number of references (153/2330, 6.6%). DynaMed had the largest total number of references (1131/2330, 48.5%) and the largest proportion of current (2007-2009) references (170/1131, 15%). The distribution of references cited for each topic varied between products. For example, asthma had the most references listed in DynaMed, Clinical Evidence, and FirstCONSULT, while hypertension had the most references in UpToDate and ACP PIER. An unexpected finding was that the rate of citation overlap was less than 1% for each topic across all five products. Conclusions Differences between POC products are revealed by examining the references cited in the monographs themselves. Citation analysis extended to include key content indicators can be used to compare the evidence levels of the literature supporting the content found in POC products. PMID:21335319

  16. The Relationship between Journal Productivity and Obsolescence.

    ERIC Educational Resources Information Center

    Wallace, Danny P.

    1986-01-01

    Examines relationship between journal productivity (number of references to particular journal) and journal obsolescence (median age of references to particular journal) for database of references dealing with desalination. Citation age by Bradford zones, continuous measurement of productivity and citation age, and underlying structure of observed…

  17. Solid state recycling of aluminium alloys via a porthole die hot extrusion process: Scaling up to production

    NASA Astrophysics Data System (ADS)

    Paraskevas, Dimos; Kellens, Karel; Deng, Yelin; Dewulf, Wim; Kampen, Carlos; Duflou, Joost R.

    2017-10-01

    Whereas industrial symbiosis has led to increased energy and resource efficiency in process industries, this concept has not yet been applied in discrete product manufacturing. Metal scrap is first conventionally recycled, for which substantial energy and resource efficiency losses have been reported. Recent research has however proven the feasibility of `meltless' recycling of light metal scrap, yielding a first glimpse of potential industrial symbiosis. Various solid state recycling techniques (such as recycling via hot extrusion or Spark Plasma Sintering) have been proposed for scrap consolidation directly into bulk products or semis by physical disruption and dispersion of the oxide surface film by imposing significant plastic and shear strain. Solid State Recycling (SSR) methods can omit substantial material losses as they bypass the metallurgical recycling step. In this context the case of direct production of bulk aluminium profiles via hot extrusion at industrial scale is demonstrated within this paper. The extrusion tests were performed directly into the production line, highlighting the scaling up potentials and the industrial relevance of this research. A significant amount of machining chips were collected, chemically cleaned and cold compacted into chip based billets with ˜80% relative density. Afterwards the scrap consolidation was achieved by imposing significant plastic and shear deformation into the material during hot extrusion through a modified 2-porthole extrusion die-set. The production process sequence along with microstructural investigations and mechanical properties comparison of the cast based profile used as reference versus the chip based profile are presented.

  18. Soil simulant sourcing for the ExoMars rover testbed

    NASA Astrophysics Data System (ADS)

    Gouache, Thibault P.; Patel, Nildeep; Brunskill, Christopher; Scott, Gregory P.; Saaj, Chakravarthini M.; Matthews, Marcus; Cui, Liang

    2011-06-01

    ExoMars is the European Space Agency (ESA) mission to Mars planned for launch in 2018, focusing on exobiology with the primary objective of searching for any traces of extant or extinct carbon-based micro-organisms. The on-surface mission is performed by a near-autonomous mobile robotic vehicle (also referred to as the rover) with a mission design life of 180 sols (Patel et al., 2010). In order to obtain useful data on the tractive performance of the ExoMars rover before flight, it is necessary to perform mobility tests on representative soil simulant materials producing a Martian terrain analogue under terrestrial laboratory conditions. Three individual types of regolith shown to be found extensively on the Martian surface were identified for replication using commercially available terrestrial materials, sourced from UK sites in order to ensure easy supply and reduce lead times for delivery. These materials (also referred to as the Engineering Soil (ES-x) simulants) are: a fine dust analogue (ES-1); a fine aeolian sand analogue (ES-2); and a coarse sand analogue (ES-3). Following a detailed analysis, three fine sand regolith types were identified from commercially available products. Each material was used in its off-the-shelf state, except for ES-2, where further processing methods were used to reduce the particle size range. These materials were tested to determine their physical characteristics, including the particle size distribution, particle density, particle shape (including angularity/sphericity) and moisture content. The results are analysed to allow comparative analysis with existing soil simulants and the published results regarding in situ analysis of Martian soil on previous NASA (National Aeronautics and Space Administration) missions. The findings have shown that in some cases material properties vary significantly from the specifications provided by material suppliers. This has confirmed the need for laboratory testing to determine the actual parameters to prove that standard geotechnical processes are indeed suitable. The outcomes have allowed the confirmation of each simulant material as suitable for replicating their respective regolith types.

  19. 33 Shafts Category of Transuranic Waste Stored Below Ground within Area G

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hargis, Kenneth Marshall; Monk, Thomas H

    This report compiles information to support the evaluation of alternatives and analysis of regulatory paths forward for the 33 shafts. The historical information includes a form completed by waste generators for each waste package (Reference 6) that included a waste description, estimates of Pu-239 and uranium-235 (U-235) based on an accounting technique, and calculations of mixed fission products (MFP) based on radiation measurements. A 1979 letter and questionnaire (Reference 7) provides information on waste packaging of hot cell waste and the configuration of disposal shafts as storage in the 33 Shafts was initiated. Tables of data by waste package weremore » developed during a review of historical documents that was performed in 2005 (Reference 8). Radiological data was coupled with material-type data to estimate the initial isotopic content of each waste package and an Oak Ridge National Laboratory computer code was used to calculate 2009 decay levels. Other sources of information include a waste disposal logbook for the 33 shafts (Reference 9), reports that summarize remote-handled waste generated at the CMR facility (Reference 10) and placement of waste in the 33 shafts (Reference 11), a report on decommissioning of the LAMPRE reactor (Reference 12), interviews with an employee and manager involved in placing waste in the 33 shafts (References 13 and 14), an interview with a long-time LANL employee involved in waste operations (Reference 15), a 2002 plan for disposition of remote-handled TRU waste (Reference 16), and photographs obtained during field surveys of several shafts in 2007. The WIPP Central Characterization Project (CCP) completed an Acceptable Knowledge (AK) summary report for 16 canisters of remote-handled waste from the CMR Facility that contains information relevant to the 33 Shafts on hot-cell operations and timeline (Reference 17).« less

  20. The application status of Good Food Production Method (GFPM) production of corn crackers in SME Mawar Merah Luwu Utara

    NASA Astrophysics Data System (ADS)

    Latief, R.; Dirpan, A.; Tahir, M. M.; Albanjar, F. V.

    2018-05-01

    Good Food Production Method (GFPM) requires several requirements that must be fulfilled by all industries involved in the whole production chain from raw materials to the fonal product. This study aims to identify the application of GFPM in the production of corn chips, and assess the status of GFPM implementation which was conducted through observations, interwiews, and documentation of all activities related to the production process. The assessment used a reference adapted from the Decree of Indonesian Minister of Industry Affairs (Permenperin) number 75/M-Ind/Per/7/2010 and the regulation of Head of National Drug and Food Control Agency (KBPOM) number HK.03.1.23.04.12.22007 in 2012. The result showed several inappropriate conditios including: (1) absence of continuing maintanace of the wall and ceiling of the production room: (2) unstandardized ventilation in the production room; (3) absence of net weight and production labels on the packages; and (4) the absence of health label informing health claims and nutrition claims. The status of GFPM implementation in UKM Mawar Merah is at D (poor) level with a rate of IV.

Top