Sample records for reference materials srms

  1. Determination of perfluorinated alkyl acid concentrations in biological standard reference materials.

    PubMed

    Reiner, Jessica L; O'Connell, Steven G; Butt, Craig M; Mabury, Scott A; Small, Jeff M; De Silva, Amila O; Muir, Derek C G; Delinsky, Amy D; Strynar, Mark J; Lindstrom, Andrew B; Reagen, William K; Malinsky, Michelle; Schäfer, Sandra; Kwadijk, Christiaan J A F; Schantz, Michele M; Keller, Jennifer M

    2012-11-01

    Standard reference materials (SRMs) are homogeneous, well-characterized materials used to validate measurements and improve the quality of analytical data. The National Institute of Standards and Technology (NIST) has a wide range of SRMs that have mass fraction values assigned for legacy pollutants. These SRMs can also serve as test materials for method development, method validation, and measurement for contaminants of emerging concern. Because inter-laboratory comparison studies have revealed substantial variability of measurements of perfluoroalkyl acids (PFAAs), future analytical measurements will benefit from determination of consensus values for PFAAs in SRMs to provide a means to demonstrate method-specific performance. To that end, NIST, in collaboration with other groups, has been measuring concentrations of PFAAs in a variety of SRMs. Here we report levels of PFAAs and perfluorooctane sulfonamide (PFOSA) determined in four biological SRMs: fish tissue (SRM 1946 Lake Superior Fish Tissue, SRM 1947 Lake Michigan Fish Tissue), bovine liver (SRM 1577c), and mussel tissue (SRM 2974a). We also report concentrations for three in-house quality-control materials: beluga whale liver, pygmy sperm whale liver, and white-sided dolphin liver. Measurements in SRMs show an array of PFAAs, with perfluorooctane sulfonate (PFOS) being the most frequently detected. Reference and information values are reported for PFAAs measured in these biological SRMs.

  2. Polyfluorinated substances in abiotic standard reference materials

    EPA Science Inventory

    The National Institute of Standards and Technology (NIST) has a wide range of Standard Reference Materials (SRMs) which have values assigned for legacy organic pollutants and toxic elements. Existing SRMs serve as homogenous materials that can be used for method development, meth...

  3. Determination of Perfluorinated Alkyl Acid Concentrations in Biological Standard Reference Materials

    EPA Science Inventory

    Standard reference materials (SRMs) are homogeneous, well-characterized materials used to validate measurements and improve the quality of analytical data. The National Institute of Standards and Technology (NIST) has a wide range of SRMs that have mass fraction values assigned ...

  4. Polyfluorinated substances in abiotic standard reference materials.

    PubMed

    Reiner, Jessica L; Blaine, Andrea C; Higgins, Christopher P; Huset, Carin; Jenkins, Thomas M; Kwadijk, Christiaan J A F; Lange, Cleston C; Muir, Derek C G; Reagen, William K; Rich, Courtney; Small, Jeff M; Strynar, Mark J; Washington, John W; Yoo, Hoon; Keller, Jennifer M

    2015-04-01

    The National Institute of Standards and Technology (NIST) has a wide range of Standard Reference Materials (SRMs) which have values assigned for legacy organic pollutants and toxic elements. Existing SRMs serve as homogenous materials that can be used for method development, method validation, and measurement for contaminants that are now of concern. NIST and multiple groups have been measuring the mass fraction of a group of emerging contaminants, polyfluorinated substances (PFASs), in a variety of SRMs. Here we report levels determined in an interlaboratory comparison of up to 23 PFASs determined in five SRMs: sediment (SRMs 1941b and 1944), house dust (SRM 2585), soil (SRM 2586), and sludge (SRM 2781). Measurements presented show an array of PFASs, with perfluorooctane sulfonate being the most frequently detected. SRMs 1941b, 1944, and 2586 had relatively low concentrations of most PFASs measured while 23 PFASs were at detectable levels in SRM 2585 and most of the PFASs measured were at detectable levels in SRM 2781. The measurements made in this study were used to add values to the Certificates of Analysis for SRMs 2585 and 2781.

  5. Characterization of Three Berry Standard Reference Materials for Nutrients

    PubMed Central

    Wood, Laura J.; Sharpless, Katherine E.; Pichon, Monique; Porter, Barbara J.; Yen, James H.; Ehling, Stefan

    2011-01-01

    The National Institute of Standards and Technology (NIST) has been working with the National Institutes of Health Office of Dietary Supplements to produce Standard Reference Materials (SRMs) of interest to analysts of dietary supplements. Some of these SRMs are traditional foods including SRM 3281 Cranberry (Fruit), SRM 3282 Low-Calorie Cranberry Juice Cocktail, and SRM 3287 Blueberry (Fruit), which have been characterized for nine nutritional elements and sugars. The blueberries have also been characterized for proximates, two water-soluble vitamins, and amino acids. These new materials are intended for use in method development and validation as well as for quality assurance and traceability when assigning values to in-house control materials. Foods can be difficult to analyze because of matrix effects. With the addition of these three new SRMs, it is now possible to more closely match controls to matrices and analyte levels for fruit and vegetable test samples. Several nutritional elements in these three SRMs are present at lower levels than those in other food-matrix SRMs. PMID:21688777

  6. Standard reference materials (SRMs) for determination of organic contaminants in environmental samples.

    PubMed

    Wise, Stephen A; Poster, Dianne L; Kucklick, John R; Keller, Jennifer M; Vanderpol, Stacy S; Sander, Lane C; Schantz, Michele M

    2006-10-01

    For the past 25 years the National Institute of Standards and Technology (NIST) has developed certified reference materials (CRMs), known as standard reference materials (SRMs), for determination of organic contaminants in environmental matrices. Assignment of certified concentrations has usually been based on combining results from two or more independent analytical methods. The first-generation environmental-matrix SRMs were issued with certified concentrations for a limited number (5 to 10) of polycyclic aromatic hydrocarbons (PAHs) and polychlorinated biphenyls (PCBs). Improvements in the analytical certification approach significantly expanded the number and classes of contaminants determined. Environmental-matrix SRMs currently available include air and diesel particulate matter, coal tar, marine and river sediment, mussel tissue, fish oil and tissue, and human serum, with concentrations typically assigned for 50 to 90 organic contaminants, for example PAHs, nitro-substituted PAHs, PCBs, chlorinated pesticides, and polybrominated diphenyl ethers (PBDEs).

  7. Polyfluorinated substances in abiotic standard reference ...

    EPA Pesticide Factsheets

    The National Institute of Standards and Technology (NIST) has a wide range of Standard Reference Materials (SRMs) which have values assigned for legacy organic pollutants and toxic elements. Existing SRMs serve as homogenous materials that can be used for method development, method validation, and measurement for contaminants that are now of concern. NIST and multiple groups have been measuring the mass fraction of a group of emerging contaminants, polyfluorinated substances (PFASs), in a variety of SRMs. Here we report levels determined in an interlaboratory comparison of up to 23 PFASs determined in five SRMs: sediment (SRMs 1941b and 1944), house dust (SRM 2585), soil (SRM 2586), and sludge (SRM 2781). Measurements presented show an array of PFASs, with perfluorooctane sulfonate being the most frequently detected. SRMs 1941b, 1944, and 2586 had relatively low concentrations of most PFASs measured while 23 PFASs were at detectable levels in SRM 2585 and most of the PFASs measured were at detectable levels in SRM 2781. The measurements made in this study were used to add values to the Certificates of Analysis for SRMs 2585 and 2781. Journal article published in Analytical and Bioanalytical Chemistry

  8. Determination of perfluorinated alkyl acid concentrations in human serum and milk standard reference materials.

    PubMed

    Keller, Jennifer M; Calafat, Antonia M; Kato, Kayoko; Ellefson, Mark E; Reagen, William K; Strynar, Mark; O'Connell, Steven; Butt, Craig M; Mabury, Scott A; Small, Jeff; Muir, Derek C G; Leigh, Stefan D; Schantz, Michele M

    2010-05-01

    Standard Reference Materials (SRMs) are certified reference materials produced by the National Institute of Standards and Technology that are homogeneous materials well characterized with values for specified properties, such as environmental contaminant concentrations. They can be used to validate measurement methods and are critical in improving data quality. Disagreements in perfluorinated alkyl acid (PFAA) concentrations measured in environmental matrices during past interlaboratory comparisons emphasized the need for SRMs with values assigned for PFAAs. We performed a new interlaboratory comparison among six laboratories and provided, for the first time, value assignment of PFAAs in SRMs. Concentrations for perfluorooctane sulfonate (PFOS), perfluorooctanoate (PFOA), and other PFAAs in two human serum and two human milk SRMs are reported. PFAA concentration measurements agreed for serum SRM 1957 using different analytical methods in six laboratories and for milk SRM 1954 in three laboratories. The interlaboratory relative standard deviation for PFOS in SRM 1957 was 7%, which is an improvement over past interlaboratory studies. Matrix interferences are discussed, as well as temporal trends and the percentage of branched vs. linear isomers. The concentrations in these SRMs are similar to the present-day average concentrations measured in human serum and milk, resulting in representative and useful control materials for PFAA human monitoring studies.

  9. STANDARD REFERENCE MATERIALS FOR THE POLYMERS INDUSTRY.

    PubMed

    McDonough, Walter G; Orski, Sara V; Guttman, Charles M; Migler, Kalman D; Beers, Kathryn L

    2016-01-01

    The National Institute of Standards and Technology (NIST) provides science, industry, and government with a central source of well-characterized materials certified for chemical composition or for some chemical or physical property. These materials are designated Standard Reference Materials ® (SRMs) and are used to calibrate measuring instruments, to evaluate methods and systems, or to produce scientific data that can be referred readily to a common base. In this paper, we discuss the history of polymer based SRMs, their current status, and challenges and opportunities to develop new standards to address industrial measurement challenges.

  10. Isotope dilution inductively coupled plasma mass spectrometry (ID ICP-MS) for the certification of lead and cadmium in environmental standard reference materials.

    PubMed

    Murphy, K E; Beary, E S; Rearick, M S; Vocke, R D

    2000-10-01

    Lead (Pb) and cadmium (Cd) have been determined in six new environmental standard reference materials (SRMs) using isotope dilution inductively coupled plasma mass spectrometry (ID ICP-MS). The SRMs are the following: SRM 1944, New York-New Jersey Waterway Sediment, SRMs 2583 and 2584, Trace Elements in Indoor Dust, Nominal 90 mg/kg and 10,000 mg/kg Lead, respectively, SRMs 2586 and 2587, Trace Elements in Soil Containing Lead from Paint, Nominal 500 mg/kg and 3,000 mg/kg Lead, respectively, and SRM 2782, Industrial Sludge. The capabilities of ID ICP-MS for the certification of Pb and Cd in these materials are assessed. Sample preparation and ratio measurement uncertainties have been evaluated. Reproducibility and accuracy of the established procedures are demonstrated by determination of gravimetrically prepared primary standard solutions and by comparison with isotope dilution thermal ionization mass spectrometry (ID TIMS). Material heterogeneity was readily demonstrated to be the dominant source of uncertainty in the certified values.

  11. The development and certification of Standard Reference Materials (SRMs) to assess and ensure accurate measurement of Pb in the environment.

    PubMed

    Fassett, J D; MacDonald, B S

    2001-08-01

    The National Institute of Standards and Technology (NIST) has had a major quality-assurance role in the federal effort to reduce lead poisoning of children in the United States through its mission of ensuring the accuracy of chemical measurements. NIST certifies reference materials (standard reference materials--SRMs) that are used to benchmark measurements by secondary and field methods of analysis--to ensure that decisions of great health and economic impact are soundly based on good measurement science. Over the past 10 years, in cooperation with the US Environmental Protection Agency (EPA), US Department of Housing and Urban Development (HUD), and the United States Geological Survey (USGS), NIST has prepared and certified SRMs for lead content in soil, indoor dust, and paint. The role of these materials in meeting regulatory and abatement needs is described and their certified values are summarized.

  12. Preparation of Reference Material 8504, Transformer Oil

    PubMed Central

    Poster, Dianne L.; Schantz, Michele M.; Wise, Stephen A.

    2005-01-01

    A new reference material (RM), RM 8504, has been prepared for use as a diluent oil with Aroclors in transformer oil Standard Reference Materials (SRMs) 3075 to 3080 and SRM 3090 when developing and validating methods for the determination of polychlorinated biphenyls (PCBs) as Aroclors in transformer oil or similar matrices. SRMs 3075-3080 and SRM 3090 consist of individual Aroclors in the same transformer oil that was used to prepare RM 8504. A unit of RM 8504 consists of one bottle containing approximately 100 mL of transformer oil. No additional constituents have been added to the oil. PMID:27308183

  13. Polychlorinated biphenyls (PCB), chlorinated pesticides, and polycyclic aromatic hydrocarbons (PAHs) in environmental standard reference materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poster, D.L.; Schantz, M.M.; Parris, R.M.

    1995-12-31

    Standard reference materials (SRMs) are certified reference materials issued by the National Institute of Standards and Technology (NIST). Natural matrix environmental sample SRMs have been developed the Analytical Chemistry Division to assist in validating measurements for organic contaminants in the environment. Many of these are well characterized for contaminants such as polychlorinated biphenyls (PCBs), chlorinated pesticides, and polycyclic aromatic hydrocarbons (PAHs). SRM 1649, Organics in Urban Dust, is currently available with certified concentrations for 5 PAHs but because of the widespread use of this material in air pollution monitoring programs and to expand the usefulness of this material, the authorsmore » are further characterizing the material for a larger number of PAHs as well as PCBs and chlorinated pesticides. They will also soon issue a diesel particulate extract (SRM 1975) that is well characterized for PAHS, including many nitrogen substituted compounds. In addition to natural matrix materials, solutions useful for calibrating chromatographic detector response factors and retention times, and spiking sample blanks for determination of analyte recoveries, are also available. Solution SRMs currently available contain PCS congeners, chlorinated pesticides, and PAHs. New solution SRMs in preparation will contain additional chlorinated pesticides, PCB congeners (e.g., non-ortho substituted chlorobiphenyls), and perdeuterated PAHs. Recent SRM work will be presented with particular attention on the methods used for determining organic contaminant concentrations in the urban dust material and in the diesel particulate extract.« less

  14. Characterization of NIST food-matrix Standard Reference Materials for their vitamin C content.

    PubMed

    Thomas, Jeanice B; Yen, James H; Sharpless, Katherine E

    2013-05-01

    The vitamin C concentrations in three food-matrix Standard Reference Materials (SRMs) from the National Institute of Standards and Technology (NIST) have been determined by liquid chromatography (LC) with absorbance detection. These materials (SRM 1549a Whole Milk Powder, SRM 1849a Infant/Adult Nutritional Formula, and SRM 3233 Fortified Breakfast Cereal) have been characterized to support analytical measurements made by food processors that are required to provide information about their products' vitamin C content on the labels of products distributed in the United States. The SRMs are primarily intended for use in validating analytical methods for the determination of selected vitamins, elements, fatty acids, and other nutrients in these materials and in similar matrixes. They can also be used for quality assurance in the characterization of test samples or in-house control materials, and for establishing measurement traceability. Within-day precision of the LC method used to measure vitamin C in the food-matrix SRMs characterized in this study ranged from 2.7% to 6.5%.

  15. Development of saw palmetto (Serenoa repens) fruit and extract standard reference materials.

    PubMed

    Schantz, Michele M; Bedner, Mary; Long, Stephen E; Molloy, John L; Murphy, Karen E; Porter, Barbara J; Putzbach, Karsten; Rimmer, Catherine A; Sander, Lane C; Sharpless, Katherine E; Thomas, Jeanice B; Wise, Stephen A; Wood, Laura J; Yen, James H; Yarita, Takashi; NguyenPho, Agnes; Sorenson, Wendy R; Betz, Joseph M

    2008-10-01

    As part of a collaboration with the National Institutes of Health's Office of Dietary Supplements and the Food and Drug Administration's Center for Drug Evaluation and Research, the National Institute of Standards and Technology has developed two standard reference materials (SRMs) representing different forms of saw palmetto (Serenoa repens), SRM 3250 Serenoa repens fruit and SRM 3251 Serenoa repens extract. Both of these SRMs have been characterized for their fatty acid and phytosterol content. The fatty acid concentration values are based on results from gas chromatography with flame ionization detection (GC-FID) and mass spectrometry (GC/MS) analysis while the sterol concentration values are based on results from GC-FID and liquid chromatography with mass spectrometry analysis. In addition, SRM 3250 has been characterized for lead content, and SRM 3251 has been characterized for the content of beta-carotene and tocopherols. SRM 3250 (fruit) has certified concentration values for three phytosterols, 14 fatty acids as triglycerides, and lead along with reference concentration values for four fatty acids as triglycerides and 16 free fatty acids. SRM 3251 (extract) has certified concentration values for three phytosterols, 17 fatty acids as triglycerides, beta-carotene, and gamma-tocopherol along with reference concentration values for three fatty acids as triglycerides, 17 fatty acids as free fatty acids, beta-carotene isomers, and delta-tocopherol and information values for two phytosterols. These SRMs will complement other reference materials currently available with concentrations for similar analytes and are part of a series of SRMs being developed for dietary supplements.

  16. Development of urine standard reference materials for metabolites of organic chemicals including polycyclic aromatic hydrocarbons, phthalates, phenols, parabens, and volatile organic compounds.

    PubMed

    Schantz, Michele M; Benner, Bruce A; Heckert, N Alan; Sander, Lane C; Sharpless, Katherine E; Vander Pol, Stacy S; Vasquez, Y; Villegas, M; Wise, Stephen A; Alwis, K Udeni; Blount, Benjamin C; Calafat, Antonia M; Li, Zheng; Silva, Manori J; Ye, Xiaoyun; Gaudreau, Éric; Patterson, Donald G; Sjödin, Andreas

    2015-04-01

    Two new Standard Reference Materials (SRMs), SRM 3672 Organic Contaminants in Smokers' Urine (Frozen) and SRM 3673 Organic Contaminants in Non-Smokers' Urine (Frozen), have been developed in support of studies for assessment of human exposure to select organic environmental contaminants. Collaborations among three organizations resulted in certified values for 11 hydroxylated polycyclic aromatic hydrocarbons (OH-PAHs) and reference values for 11 phthalate metabolites, 8 environmental phenols and parabens, and 24 volatile organic compound (VOC) metabolites. Reference values are also available for creatinine and the free forms of caffeine, theobromine, ibuprofen, nicotine, cotinine, and 3-hydroxycotinine. These are the first urine Certified Reference Materials characterized for metabolites of organic environmental contaminants. Noteworthy, the mass fractions of the environmental organic contaminants in the two SRMs are within the ranges reported in population survey studies such as the National Health and Nutrition Examination Survey (NHANES) and the Canadian Health Measures Survey (CHMS). These SRMs will be useful as quality control samples for ensuring compatibility of results among population survey studies and will fill a void to assess the accuracy of analytical methods used in studies monitoring human exposure to these organic environmental contaminants.

  17. Development of urine standard reference materials for metabolites of organic chemicals including polycyclic aromatic hydrocarbons, phthalates, phenols, parabens, and volatile organic compounds

    PubMed Central

    Schantz, Michele M.; Benner, Bruce A.; Heckert, N. Alan; Sander, Lane C.; Sharpless, Katherine E.; Vander Pol, Stacy S.; Vasquez, Y.; Villegas, M.; Wise, Stephen A.; Alwis, K. Udeni; Blount, Benjamin C.; Calafat, Antonia M.; Li, Zheng; Silva, Manori J.; Ye, Xiaoyun; Gaudreau, Éric; Patterson, Donald G.; Sjödin, Andreas

    2016-01-01

    Two new Standard Reference Materials (SRMs), SRM 3672 Organic Contaminants in Smokers’ Urine (Frozen) and SRM 3673 Organic Contaminants in Non-Smokers’ Urine (Frozen), have been developed in support of studies for assessment of human exposure to select organic environmental contaminants. Collaborations among three organizations resulted in certified values for 11 hydroxylated polycyclic aromatic hydrocarbons (OH-PAHs) and reference values for 11 phthalate metabolites, 8 environmental phenols and parabens, and 24 volatile organic compound (VOC) metabolites. Reference values are also available for creatinine and the free forms of caffeine, theobromine, ibuprofen, nicotine, cotinine, and 3-hydroxycotinine. These are the first urine Certified Reference Materials characterized for metabolites of organic environmental contaminants. Noteworthy, the mass fractions of the environmental organic contaminants in the two SRMs are within the ranges reported in population survey studies such as the National Health and Nutrition Examination Survey (NHANES) and the Canadian Health Measures Survey (CHMS). These SRMs will be useful as quality control samples for ensuring compatibility of results among population survey studies and will fill a void to assess the accuracy of analytical methods used in studies monitoring human exposure to these organic environmental contaminants. PMID:25651899

  18. Preparation and characterization of a suite of ephedra-containing standard reference materials.

    PubMed

    Sharpless, Katherine E; Anderson, David L; Betz, Joseph M; Butler, Therese A; Capar, Stephen G; Cheng, John; Fraser, Catharine A; Gardner, Graeme; Gay, Martha L; Howell, Daniel W; Ihara, Toshihide; Khan, Mansoor A; Lam, Joseph W; Long, Stephen E; McCooeye, Margaret; Mackey, Elizabeth A; Mindak, William R; Mitvalsky, Staci; Murphy, Karen E; NguyenPho, Agnes; Phinney, Karen W; Porter, Barbara J; Roman, Mark; Sander, Lane C; Satterfield, Mary B; Scriver, Christine; Sturgeon, Ralph; Thomas, Jeanice Brown; Vocke, Robert D; Wise, Stephen A; Wood, Laura J; Yang, Lu; Yen, James H; Ziobro, George C

    2006-01-01

    The National Institute of Standards and Technology, the U.S. Food and Drug Administration, Center for Drug Evaluation and Research and Center for Food Safety and Applied Nutrition, and the National Institutes of Health, Office of Dietary Supplements, are collaborating to produce a series of Standard Reference Materials (SRMs) for dietary supplements. A suite of ephedra materials is the first in the series, and this paper describes the acquisition, preparation, and value assignment of these materials: SRMs 3240 Ephedra sinica Stapf Aerial Parts, 3241 E. sinica Stapf Native Extract, 3242 E. sinica Stapf Commercial Extract, 3243 Ephedra-Containing Solid Oral Dosage Form, and 3244 Ephedra-Containing Protein Powder. Values are assigned for ephedrine alkaloids and toxic elements in all 5 materials. Values are assigned for other analytes (e.g., caffeine, nutrient elements, proximates, etc.) in some of the materials, as appropriate. Materials in this suite of SRMs are intended for use as primary control materials when values are assigned to in-house (secondary) control materials and for validation of analytical methods for the measurement of alkaloids, toxic elements, and, in the case of SRM 3244, nutrients in similar materials.

  19. Speciation of strontium-90 in NIST natural matrix standard reference materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thomas, J.W.L.; Inn, K.G.W.; Garcia, M.E.

    1995-12-31

    A sequential leaching, radiochemical separating, and low-level beta-particle counting procedure was designed to study the speciation of radionuclides in natural matrix standard reference materials, SRMs 4350B (Columbia River Sediment) and 4353 (Rocky Flats Soil-1). Strontium-90 is the first radionuclide studied because of the difficulty experienced with this nuclide in natural-matrix SRMs. The nine-step procedure extracted {sup 90}Sr from the following fractions: water solubles, exchangeables, carbonates, reducibles, organics, iron and manganese oxides, acid leachables, micas, and silicates. The majority of {sup 90}Sr in the soil samples was found in the exchangeable fraction. By contrast, the {sup 90}Sr in the sediment ismore » more evenly distributed among the various leached fractions. Information on the leach distribution of radionuclides in environmental SRMs, based on the procedure described, should lead to more cost-effective restoration strategies and more confidence in risk assessments of human health hazards.« less

  20. NBS/EPA (NATIONAL BUREAU OF STANDARDS/ENVIRONMENTAL PROTECTION AGENCY) CERTIFIED REFERENCE MATERIAL PERFORMANCE AUDIT PROGRAM: STATUS REPORT 1

    EPA Science Inventory

    A traceability procedure has been established which allows specialty gas producers to prepare gaseous pollutant Certified Reference Materials (CRMs). The accuracy, stability and homogeneity of the CRMs approach those of NBS Standard Reference Materials (SRMs). Part of this proced...

  1. Determination of polychlorinated dibenzo-p-dioxin and dibenzofuran congeners in air particulate and marine sediment standard reference materials (SRMs).

    PubMed

    Chiu, C H; Turle, R; Poole, G; Thibert, B; Brubaker, W W; Schantz, M M; Wise, S A

    2001-02-01

    Due to the limited number of environmental matrix certified reference materials (CRMs) with assigned values for natural levels of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), an interlaboratory study was undertaken by the National Institute of Standards and Technology (NIST) and Environment Canada to establish reference concentration values for selected PCDD/Fs in two well-characterized NIST Standard Reference Materials (SRMs): SRM 1649a (Urban Dust) and SRM 1944 (New York/New Jersey Waterway Sediment). Results from 14 laboratories were used to provide reference values for the seventeen 2, 3, 7, 8-substituted PCDD/F congeners, the totals for individual tetra- through hepta-substituted PCDD/F homologues, and the total amount of tetra- through hepta-substituted PCDD/Fs. The mass fractions for the individual 2, 3, 7, 8-substituted congeners range from approximately 0.01 microg/kg to 7 microg/kg dry mass.

  2. Three new mussel tissue standard reference materials (SRMs) for the determination of organic contaminants.

    PubMed

    Poster, Dianne L; Schantz, Michele M; Kucklick, John R; Lopez de Alda, Maria J; Porter, Barbara J; Pugh, Rebecca; Wise, Stephen A

    2004-03-01

    Three new mussel tissue standard reference materials (SRMs) have been developed by the National Institute of Standards and Technology (NIST) for the determination of the concentrations of organic contaminants. The most recently prepared material, SRM 1974b, is a fresh frozen tissue homogenate prepared from mussels ( Mytilus edulis) collected in Boston Harbor, Massachusetts. The other two materials, SRMs 2977 and 2978, are freeze-dried tissue homogenates prepared from mussels collected in Guanabara Bay, Brazil and Raritan Bay, New Jersey, respectively. All three new mussel tissue SRMs complement the current suite of marine natural-matrix SRMs available from NIST that are characterized for a wide range of contaminants (organic and inorganic). SRM 1974b has been developed to replace its predecessor SRM 1974a, Organics in Mussel Tissue, for which the supply is depleted. Similarly, SRMs 2977 and 2978 were developed to replace a previously available (supply depleted) freeze-dried version of SRM 1974a, SRM 2974, Organics in Freeze-Dried Mussel Tissue. SRM 1974b is the third in a series of fresh frozen mussel tissue homogenate SRMs prepared from mussels collected in Boston Harbor starting in 1988. SRM 1974b has certified concentration values for 22 polycyclic aromatic hydrocarbons (PAHs), 31 polychlorinated biphenyl congeners (PCBs), and 7 chlorinated pesticides. Reference values are provided for additional constituents: 16 PAHs, 8 PCBs plus total PCBs, 6 pesticides, total extractable organics, methylmercury, and 11 trace elements. PAH concentrations range from about 2 ng g(-1 )dry mass (cyclopenta[ cd]pyrene) to 180 ng g(-1 )dry mass (pyrene). PCB concentrations range from about 2 ng g(-1 )dry mass (PCB 157) to 120 ng g(-1 )dry mass (PCB 153). The reference value for total PCBs in SRM 1974b is (2020 +/- 420) ng g(-1 )dry mass. Pesticide concentrations range from about 4 ng g(-1 )dry mass (4,4'-DDT) to 40 ng g(-1 )dry mass (4,4'-DDE). SRM 2977 has certified values for 14 PAHs, 25 PCB congeners, 7 pesticides, 6 trace elements, and methylmercury. Reference values for 16 additional PAHs and 9 inorganic constituents are provided, and information values are given for 23 additional trace elements. SRM 2978 has certified and reference concentrations for 41 and 22 organic compounds, respectively, and contains contaminant levels similar to those of SRM 1974b. Organic contaminant levels in SRM 2977 (mussels from Guanabara Bay, Brazil) are typically a factor of 2 to 4 lower than those in SRM 1974b and SRM 2978. The organic contaminant concentrations in each new mussel tissue SRM are presented and compared in this paper. In addition, a chronological review of contaminant concentrations associated with mussels collected in Boston Harbor is discussed as well as a stability assessment of SRM 1974a.

  3. REFERENCE MATERIALS AND QUALITY ASSURANCE FOR THE CHARACTERIZATION OF ORGANIC COMPOUNDS IN PARTICULATE MATTER

    EPA Science Inventory

    One of the first environmental matrix Standard Reference Materials (SRMs) developed by the National Institute of Standards and Technology (NIST) for determination of organic species was SRM 1649 Urban Dust, ambient total suspended particulate matter (PM) collected in Washington D...

  4. Liquid chromatography with absorbance detection and with isotope-dilution mass spectrometry for determination of isoflavones in soy standard reference materials.

    PubMed

    Phillips, Melissa M; Bedner, Mary; Reitz, Manuela; Burdette, Carolyn Q; Nelson, Michael A; Yen, James H; Sander, Lane C; Rimmer, Catherine A

    2017-02-01

    Two independent analytical approaches, based on liquid chromatography with absorbance detection and liquid chromatography with mass spectrometric detection, have been developed for determination of isoflavones in soy materials. These two methods yield comparable results for a variety of soy-based foods and dietary supplements. Four Standard Reference Materials (SRMs) have been produced by the National Institute of Standards and Technology to assist the food and dietary supplement community in method validation and have been assigned values for isoflavone content using both methods. These SRMs include SRM 3234 Soy Flour, SRM 3236 Soy Protein Isolate, SRM 3237 Soy Protein Concentrate, and SRM 3238 Soy-Containing Solid Oral Dosage Form. A fifth material, SRM 3235 Soy Milk, was evaluated using the methods and found to be inhomogeneous for isoflavones and unsuitable for value assignment. Graphical Abstract Separation of six isoflavone aglycones and glycosides found in Standard Reference Material (SRM) 3236 Soy Protein Isolate.

  5. Reference Materials for Food and Nutrition Metrology: Past, Present and Future

    USDA-ARS?s Scientific Manuscript database

    Establishment of a metrology-based measurement system requires the solid foundation of traceability of measurements to available, appropriate certified reference materials (CRM). In the early 1970’s the first “biological” RM of Bowens Kale, as well as Orchard Leaves and Bovine Liver SRMs, from the ...

  6. Standard Reference Materials (SRMs) for the Calibration and Validation of Analytical Methods for PCBs (as Aroclor Mixtures)

    PubMed Central

    Poster, Dianne L.; Schantz, Michele M.; Leigh, Stefan D.; Wise, Stephen A.

    2004-01-01

    Six Standard Reference Materials (SRMs®) have been prepared by the National Institute of Standards and Technology (NIST) for the determination of PCBs as different Aroclor mixtures in methanol. Six additional SRMs of the same Aroclors in transformer oil have also been prepared. Specifically, solutions of Aroclors 1016, 1232, 1242, 1254, and 1260 have been gravimetrically prepared (individually) in methanol and transformer oil, mixed, and transferred to amber glass ampoules in approximately 1.2 mL aliquots. Gas chromatography with electron capture detection (GC-ECD) has been used to verify the gravimetric data for each solution and transformer oil SRM. Liquid chromatography was used for the isolation of the Aroclors from the transformer oil SRMs prior to GC-ECD analysis. Separate calibration solutions and oils were prepared with Aroclor levels similar to those in each methanol solution and transformer oil SRM and were processed alongside the samples. The GC-ECD response of each Aroclor was monitored relative to internal standards that were added to the complex mixtures for quantification. The gravimetric concentrations of Aroclors 1242 and 1254 in methanol were also examined by the same method of analysis (GC-ECD) using several different sources of Aroclors and two different capillary GC columns: a 5 % phenyl methylpolysiloxane phase and a relatively non-polar phase. The preparation of the materials, the gas chromatographic results, and the certified concentration values for each Aroclor SRM are described in this paper. PMID:27366608

  7. Determination of polycyclic aromatic hydrocarbons with molecular weight 300 and 302 in environmental-matrix standard reference materials by gas chromatography/mass spectrometry.

    PubMed

    Schubert, Patricia; Schantz, Michele M; Sander, Lane C; Wise, Stephen A

    2003-01-15

    An analytical approach based on gas chromatography/ mass spectrometry (GC/MS) is presented for the measurement of polycyclic aromatic hydrocarbons with molecular weight (MW) 300 and 302 in environmental samples. Three different GC stationary phases [5% and 50% phenyl methylpolysiloxane and dimethyl (50% liquid crystalline) polysiloxane] were compared, and retention indexes (RI) are given for 23 individual MW 302 isomers. Identification of MW 300 and 302 isomers in four environmental-matrix Standard Reference Materials (SRMs) (SRM 1597, coal tar extract; SRM 1648 and SRM 1649a, air particulate matter; and SRM 1941, marine sediment) was based on the comparison of RI data and mass spectra from authentic standards. Dibenzo[a,l]pyrene, which is of considerable interest because of its high carcinogenicity, was identified and quantified in the four environmental-matrix SRMs. A total of 23 isomers of MW 302 and four isomers of MW 300 were quantified in four different environmental-matrix SRMs, and the results are compared to previously reported results based on liquid chromatography with fluorescence detection.

  8. Liquid Chromatography with Absorbance Detection and with Isotope-Dilution Mass Spectrometry for Determination of Isoflavones in Soy Standard Reference Materials

    PubMed Central

    Phillips, Melissa M.; Bedner, Mary; Gradl, Manuela; Burdette, Carolyn Q.; Nelson, Michael A.; Yen, James H.; Sander, Lane C.; Rimmer, Catherine A.

    2017-01-01

    Two independent analytical approaches, based on liquid chromatography with absorbance detection and liquid chromatography with mass spectrometric detection, have been developed for determination of isoflavones in soy materials. These two methods yield comparable results for a variety of soy-based foods and dietary supplements. Four Standard Reference Materials (SRMs) have been produced by the National Institute of Standards and Technology to assist the food and dietary supplement community in method validation and have been assigned values for isoflavone content using both methods. These SRMs include SRM 3234 Soy Flour, SRM 3236 Soy Protein Isolate, SRM 3237 Soy Protein Concentrate, and SRM 3238 Soy-Containing Solid Oral Dosage Form. A fifth material, SRM 3235 Soy Milk, was evaluated using the methods and found to be inhomogeneous for isoflavones and unsuitable for value assignment. PMID:27832301

  9. Synthetic musk fragrances in environmental Standard Reference Materials.

    PubMed

    Peck, Aaron M; Kucklick, John R; Schantz, Michele M

    2007-04-01

    Synthetic musk fragrances have been measured in water, air, sediments, sewage sludge, and biota worldwide. As the study of the environmental fate and impacts of these compounds progresses, the need for Standard Reference Materials (SRMs) for these compounds to facilitate analytical method improvement and interlaboratory comparisons becomes increasingly important. The National Institute of Standards and Technology (NIST) issues environmental matrix SRMs with certified concentrations for a variety of persistent organic pollutants including polycyclic aromatic hydrocarbons (PAHs), chlorinated pesticides, and polychlorinated biphenyl congeners (PCBs). Until now synthetic musk fragrance concentrations have not been reported in NIST SRMs. The objective of this study was to provide reference values for several commonly detected synthetic musk fragrances in several NIST natural matrix SRMs. In this study five polycyclic musk fragrances [HHCB (1,3,4,6,7,8-hexahydro-4,6,6,7,8,8-hexamethylcyclopenta-gamma-2-benzopyran), AHTN (7-acetyl-1,1,3,4,4,6-hexamethyl-1,2,3,4-tetrahydronaphthalene), ADBI (4-acetyl-1,1-dimethyl-6-tert-butylindane), AHMI (6-acetyl-1,1,2,3,3,5-hexamethylindane), and ATII (5-acetyl-1,1,2,6-tetramethyl-3-isopropylindane] and two nitro musk fragrances [musk xylene (1-tert-butyl-3,5-dimethyl-2,4,6-trinitrobenzene) and musk ketone (4-tert-butyl-3,5-dinitro-2,6-dimethylacetophenone)] were measured in selected environmental SRMs. Gas chromatography-electron impact mass spectrometry (GC/EI-MS) was used for all analyses. HHCB was the most frequently detected synthetic musk fragrance and was detected in SRM 2585 Organic Contaminants in House Dust, SRM 2781 Domestic Sludge, SRM 1974b Organics in Mussel Tissue (Mytilus edulis), and SRM 1947 Lake Michigan Fish Tissue. It was not detected in SRM 1946 Lake Superior Fish Tissue or SRM 1945 Organics in Whale Blubber. Concentrations of HHCB in these SRMs ranged from 1.12 ng/g in SRM 1947 to 92,901 ng/g in SRM 2781. All of the polycyclic musk fragrances were detected in SRM 2781 and all of the target compounds were detected in SRM 2585.

  10. Role of chromatography in the development of Standard Reference Materials for organic analysis.

    PubMed

    Wise, Stephen A; Phinney, Karen W; Sander, Lane C; Schantz, Michele M

    2012-10-26

    The certification of chemical constituents in natural-matrix Standard Reference Materials (SRMs) at the National Institute of Standards and Technology (NIST) can require the use of two or more independent analytical methods. The independence among the methods is generally achieved by taking advantage of differences in extraction, separation, and detection selectivity. This review describes the development of the independent analytical methods approach at NIST, and its implementation in the measurement of organic constituents such as contaminants in environmental materials, nutrients and marker compounds in food and dietary supplement matrices, and health diagnostic and nutritional assessment markers in human serum. The focus of this review is the important and critical role that separation science techniques play in achieving the necessary independence of the analytical steps in the measurement of trace-level organic constituents in natural matrix SRMs. Published by Elsevier B.V.

  11. Role of the National Institute of Standards and Technology (NIST) in Support of the Vitamin D Initiative of the National Institutes of Health, Office of Dietary Supplements.

    PubMed

    Wise, Stephen A; Tai, Susan S-C; Burdette, Carolyn Q; Camara, Johanna E; Bedner, Mary; Lippa, Katrice A; Nelson, Michael A; Nalin, Federica; Phinney, Karen W; Sander, Lane C; Betz, Joseph M; Sempos, Christopher T; Coates, Paul M

    2017-09-01

    Since 2005, the National Institute of Standards and Technology (NIST) has collaborated with the National Institutes of Health (NIH), Office of Dietary Supplements (ODS) to improve the quality of measurements related to human nutritional markers of vitamin D status. In support of the NIH-ODS Vitamin D Initiative, including the Vitamin D Standardization Program (VDSP), NIST efforts have focused on (1) development of validated analytical methods, including reference measurement procedures (RMPs); (2) development of Standard Reference Materials (SRMs); (3) value assignment of critical study samples using NIST RMPs; and (4) development and coordination of laboratory measurement QA programs. As a result of this collaboration, NIST has developed RMPs for 25-hydroxyvitamin D2 [25(OH)D2], 25(OH)D3, and 24R,25-dihydroxyvitamin D3 [24R,25(OH)2D3]; disseminated serum-based SRMs with values assigned for 25(OH)D2, 25(OH)D3, 3-epi-25(OH)D3, and 24R,25(OH)2D3; assigned values for critical samples for VDSP studies, including an extensive interlaboratory comparison and reference material commutability study; provided an accuracy basis for the Vitamin D External Quality Assurance Scheme; coordinated the first accuracy-based measurement QA program for the determination of 25(OH)D2, 25(OH)D3, and 3-epi-25(OH)D3 in human serum/plasma; and developed methods and SRMs for the determination of vitamin D and 25(OH)D in food and supplement matrix SRMs. The details of these activities and their benefit and impact to the NIH-ODS Vitamin D Initiative are described.

  12. Characterizing Vaccinium berry Standard Reference Materials by GC-MS using NIST spectral libraries.

    PubMed

    Lowenthal, Mark S; Andriamaharavo, Nirina R; Stein, Stephen E; Phinney, Karen W

    2013-05-01

    A gas chromatography-mass spectrometry (GC-MS)-based method was developed for qualitative characterization of metabolites found in Vaccinium fruit (berry) dietary supplement Standard Reference Materials (SRMs). Definitive identifications are provided for 98 unique metabolites determined among six Vaccinium-related SRMs. Metabolites were enriched using an organic liquid/liquid extraction, and derivatized prior to GC-MS analysis. Electron ionization (EI) fragmentation spectra were searched against EI spectra of authentic standards compiled in the National Institute of Standards and Technology's mass spectral libraries, as well as spectra selected from the literature. Metabolite identifications were further validated using a retention index match along with prior probabilities and were compared with results obtained in a previous effort using collision-induced dissociation (CID) MS/MS datasets from liquid chromatography coupled to mass spectrometry experiments. This manuscript describes a nontargeted metabolite profile of Vaccinium materials, compares results among related materials and from orthogonal experimental platforms, and discusses the feasibility and development of using mass spectral library matching for nontargeted metabolite identification.

  13. New Carbonate Standard Reference Materials for Boron Isotope Geochemistry

    NASA Astrophysics Data System (ADS)

    Stewart, J.; Christopher, S. J.; Day, R. D.

    2015-12-01

    The isotopic composition of boron (δ11B) in marine carbonates is well established as a proxy for past ocean pH. Yet, before palaeoceanographic interpretation can be made, rigorous assessment of analytical uncertainty of δ11B data is required; particularly in light of recent interlaboratory comparison studies that reported significant measurement disagreement between laboratories [1]. Well characterised boron standard reference materials (SRMs) in a carbonate matrix are needed to assess the accuracy and precision of carbonate δ11B measurements throughout the entire procedural chemistry; from sample cleaning, to ionic separation of boron from the carbonate matrix, and final δ11B measurement by multi-collector inductively coupled plasma mass spectrometry. To date only two carbonate reference materials exist that have been value-assigned by the boron isotope measurement community [2]; JCp-1 (porites coral) and JCt-1 (Giant Clam) [3]. The National Institute of Standards and Technology (NIST) will supplement these existing standards with new solution based inorganic carbonate boron SRMs that replicate typical foraminiferal and coral B/Ca ratios and δ11B values. These new SRMs will not only ensure quality control of full procedural chemistry between laboratories, but have the added benefits of being both in abundant supply and free from any restrictions associated with shipment of biogenic samples derived from protected species. Here we present in-house δ11B measurements of these new boron carbonate SRM solutions. These preliminary data will feed into an interlaboratory comparison study to establish certified values for these new NIST SRMs. 1. Foster, G.L., et al., Chemical Geology, 2013. 358(0): p. 1-14. 2. Gutjahr, M., et al., Boron Isotope Intercomparison Project (BIIP): Development of a new carbonate standard for stable isotopic analyses. Geophysical Research Abstracts, EGU General Assembly 2014, 2014. 16(EGU2014-5028-1). 3. Inoue, M., et al., Geostandards and Geoanalytical Research, 2004. 28(3): p. 411-416.

  14. Determination of non-ortho polychlorinated biphenyls in environmental Standard Reference Materials.

    PubMed

    Brubaker, W W; Schantz, M M; Wise, S A

    2000-07-01

    The concentrations of three non-ortho ("coplanar") polychlorinated biphenyls, 3,3',4,4'-tetrachlorobiphenyl (IUPAC PCB 77), 3,3',4,4',5-pentachlorobiphenyl (IUPAC PCB 126), and 3,3',4,4',5,5'-hexachlorobiphenyl (IUPAC PCB 169), were determined in five NIST Standard Reference Materials (SRMs) of environmental and biological interest. The measured levels were approximately between (0.2 to 1.3) ng/g in SRM 1588a (Organics in Cod Liver Oil), (0.3 to 9) ng/g in SRM 1944 (New York/New Jersey Waterway Sediment), (0.2 to 0.4) ng/g in SRM 1945 (Organics in Whale Blubber), (1 to 18) ng/g in SRM 2974 (Organics in Freeze-dried Mussel Tissue [Mytilus edulis]), and (0.1 to 0.4) ng/g in candidate SRM 1946 (Lake Superior Fish Tissue). PCB 169 was present at < 0.1 ng/g in SRMs 1944 and 2974.

  15. Long-term stability and temporal trends of organic contaminants in four collections of mussel tissue frozen standard reference materials.

    PubMed

    Schantz, Michele M; Pugh, Rebecca S; Pol, Stacy S Vander; Wise, Stephen A

    2015-04-01

    The stability of polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), and chlorinated pesticides in frozen mussel tissue Standard Reference Materials (SRMs) stored at -80 °C was assessed by analyzing samples of SRM 1974, SRM 1974a, and SRM 1974b Organics in Mussel Tissue (Mytilus edulis) periodically over 25 y, 20 y, and 12 y, respectively. The most recent analyses were performed during the certification of the fourth release of this material, SRM 1974c. Results indicate the concentrations of these persistent organic pollutants have not changed during storage at -80 °C. In addition, brominated diphenyl ethers (BDEs) were quantified in each of the materials during this study. The stability information is important for on-going monitoring studies collecting large quantities of samples for future analyses (i.e., formally established specimen banking programs). Since all four mussel tissue SRMs were prepared from mussels collected at the same site in Dorchester Bay, MA, USA, the results provide a temporal trend study for these contaminants over a 17 year period (1987 to 2004).

  16. Accurate mass measurement by matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry. II. Measurement of negative radical ions using porphyrin and fullerene standard reference materials.

    PubMed

    Shao, Zhecheng; Wyatt, Mark F; Stein, Bridget K; Brenton, A Gareth

    2010-10-30

    A method for the accurate mass measurement of negative radical ions by matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOFMS) is described. This is an extension to our previously described method for the accurate mass measurement of positive radical ions (Griffiths NW, Wyatt MF, Kean SD, Graham AE, Stein BK, Brenton AG. Rapid Commun. Mass Spectrom. 2010; 24: 1629). The porphyrin standard reference materials (SRMs) developed for positive mode measurements cannot be observed in negative ion mode, so fullerene and fluorinated porphyrin compounds were identified as effective SRMs. The method is of immediate practical use for the accurate mass measurement of functionalised fullerenes, for which negative ion MALDI-TOFMS is the principal mass spectrometry characterisation technique. This was demonstrated by the accurate mass measurement of six functionalised C(60) compounds. Copyright © 2010 John Wiley & Sons, Ltd.

  17. Chemical Bonding and Structural Information of Black CarbonReference Materials and Individual Carbonaceous AtmosphericAerosols

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hopkins, Rebecca J.; Tivanski, Alexei V.; Marten, Bryan D.

    2007-04-25

    The carbon-to-oxygen ratios and graphitic nature of a rangeof black carbon standard reference materials (BC SRMs), high molecularmass humic-like substances (HULIS) and atmospheric particles are examinedusing scanning transmission X-ray microscopy (STXM) coupled with nearedge X-ray absorption fine structure (NEXAFS) spectroscopy. UsingSTXM/NEXAFS, individual particles with diameter>100 nm are studied,thus the diversity of atmospheric particles collected during a variety offield missions is assessed. Applying a semi-quantitative peak fittingmethod to the NEXAFS spectra enables a comparison of BC SRMs and HULIS toparticles originating from anthropogenic combustion and biomass burns,thus allowing determination of the suitability of these materials forrepresenting atmospheric particles. Anthropogenic combustion andmore » biomassburn particles can be distinguished from one another using both chemicalbonding and structural ordering information. While anthropogeniccombustion particles are characterized by a high proportion ofaromatic-C, the presence of benzoquinone and are highly structurallyordered, biomass burn particles exhibit lower structural ordering, asmaller proportion of aromatic-C and contain a much higher proportion ofoxygenated functional groups.« less

  18. Evaluation of a standardized micro-vacuum sampling method for collection of surface dust.

    PubMed

    Ashley, Kevin; Applegate, Gregory T; Wise, Tamara J; Fernback, Joseph E; Goldcamp, Michael J

    2007-03-01

    A standardized procedure for collecting dust samples from surfaces using a micro-vacuum sampling technique was evaluated. Experiments were carried out to investigate the collection efficiency of the vacuum sampling method described in ASTM Standard D7144, "Standard Practice for Collection of Surface Dust by Micro-Vacuum Sampling for Subsequent Metals Determination." Weighed masses ( approximately 5, approximately 10 and approximately 25 mg) of three NIST Standard Reference Materials (SRMs) were spiked onto surfaces of various substrates. The SRMs used were: (1) Powdered Lead-Based Paint; (2) Urban Particulate Matter; and (3) Trace Elements in Indoor Dust. Twelve different substrate materials were chosen to be representative of surfaces commonly encountered in occupational and/or indoor settings: (1) wood, (2) tile, (3) linoleum, (4) vinyl, (5) industrial carpet, (6) plush carpet, (7,8) concrete block (painted and unpainted), (9) car seat material, (10) denim, (11) steel, and (12) glass. Samples of SRMs originally spiked onto these surfaces were collected using the standardized micro-vacuum sampling procedure. Gravimetric analysis of material collected within preweighed Accucapinserts (housed within the samplers) was used to measure SRM recoveries. Recoveries ranged from 21.6% (+/- 10.4%, 95% confidence limit [CL]) for SRM 1579 from industrial carpet to 59.2% (+/- 11.0%, 95% CL) for SRM 1579 from glass. For most SRM/substrate combinations, recoveries ranged from approximately 25% to approximately 50%; variabilities differed appreciably. In general, SRM recoveries were higher from smooth and hard surfaces and lower from rough and porous surfaces. Material captured within collection nozzles attached to the sampler inlets was also weighed. A significant fraction of SRM originally spiked onto substrate surfaces was captured within collection nozzles. Percentages of SRMs captured within collection nozzles ranged from approximately 13% (+/- 4 - +/- 5%, 95% CLs) for SRMs 1579 and 2583 from industrial carpet to approximately 45% (+/- 7 - +/- 26%, 95% CLs) for SRM 1648 from glass, tile and steel. For some substrates, loose material from the substrate itself (i.e., substrate particles and fibers) was sometimes collected along with the SRM, both within Accucaps as well as collection nozzles. Co-collection of substrate material can bias results and contribute to sampling variability. The results of this work have provided performance data on the standardized micro-vacuum sampling procedure.

  19. 75 FR 4077 - Agency Information Collection Activities; Submission for Office of Management and Budget Review...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-26

    ... requirements for recordkeeping and records access for FDA-regulated human food, including dietary supplements...) Whether cattle material may contain specified risk materials (SRMs). SRMs include brain, skull, eyes...

  20. Pressurized liquid extraction of diesel and air particulate standard reference materials: effect of extraction temperature and pressure.

    PubMed

    Schantz, Michele M; McGaw, Elizabeth; Wise, Stephen A

    2012-10-02

    Four particulate matter Standard Reference Materials (SRMs) available from the National Institute of Standards and Technology (NIST) were used to evaluate the effect of solvent, number of static cycles and static times, pressure, and temperature when using pressurized liquid extraction (PLE) for the extraction of polycyclic aromatic hydrocarbons (PAHs) and nitrated-PAHs. The four materials used in the study were SRM 1648a Urban Particulate Matter, SRM 1649b Urban Dust, SRM 1650b Diesel Particulate Matter, and SRM 2975 Diesel Particulate Matter (Industrial Forklift). The results from the study indicate that the choice of solvent, dichloromethane compared to toluene and toluene/methanol mixtures, had little effect on the extraction efficiency. With three to five extraction cycles, increasing the extraction time for each cycle from 5 to 30 min had no significant effect on the extraction efficiency. The differences in extraction efficiency were not significant (with over 95% of the differences being <10%) when the pressure was increased from 13.8 to 20.7 MPa. The largest increase in extraction efficiency occurred for selected PAHs when the temperature of extraction was increased from 100 to 200 °C. At 200 °C naphthalene, biphenyl, fluorene, dibenzothiophene, and anthracene show substantially higher mass fractions (>30%) than when extracted at 100 °C in all the SRMs studied. For SRM 2975, large increases (>100%) are also observed for some other PAHs including benz[a]anthracene, benzo[k]fluoranthene, benzo[e]pyrene, benzo[a]pyrene, benzo[ghi]perylene, and benzo[b]chrysene when extracted at the higher temperatures; however, similar trends were not observed for the other diesel particulate sample, SRM 1650b. The results are discussed in relation to the use of the SRMs for evaluating analytical methods.

  1. An inductance Fourier decomposition-based current-hysteresis control strategy for switched reluctance motors

    NASA Astrophysics Data System (ADS)

    Hua, Wei; Qi, Ji; Jia, Meng

    2017-05-01

    Switched reluctance machines (SRMs) have attracted extensive attentions due to the inherent advantages, including simple and robust structure, low cost, excellent fault-tolerance and wide speed range, etc. However, one of the bottlenecks limiting the SRMs for further applications is its unfavorable torque ripple, and consequently noise and vibration due to the unique doubly-salient structure and pulse-current-based power supply method. In this paper, an inductance Fourier decomposition-based current-hysteresis-control (IFD-CHC) strategy is proposed to reduce torque ripple of SRMs. After obtaining a nonlinear inductance-current-position model based Fourier decomposition, reference currents can be calculated by reference torque and the derived inductance model. Both the simulations and experimental results confirm the effectiveness of the proposed strategy.

  2. Characterization of NIST human mitochondrial DNA SRM-2392 and SRM-2392-I standard reference materials by next generation sequencing.

    PubMed

    Riman, Sarah; Kiesler, Kevin M; Borsuk, Lisa A; Vallone, Peter M

    2017-07-01

    Standard Reference Materials SRM 2392 and 2392-I are intended to provide quality control when amplifying and sequencing human mitochondrial genome sequences. The National Institute of Standards and Technology (NIST) offers these SRMs to laboratories performing DNA-based forensic human identification, molecular diagnosis of mitochondrial diseases, mutation detection, evolutionary anthropology, and genetic genealogy. The entire mtGenome (∼16569bp) of SRM 2392 and 2392-I have previously been characterized at NIST by Sanger sequencing. Herein, we used the sensitivity, specificity, and accuracy offered by next generation sequencing (NGS) to: (1) re-sequence the certified values of the SRM 2392 and 2392-I; (2) confirm Sanger data with a high coverage new sequencing technology; (3) detect lower level heteroplasmies (<20%); and thus (4) support mitochondrial sequencing communities in the adoption of NGS methods. To obtain a consensus sequence for the SRMs as well as identify and control any bias, sequencing was performed using two NGS platforms and data was analyzed using different bioinformatics pipelines. Our results confirm five low level heteroplasmy sites that were not previously observed with Sanger sequencing: three sites in the GM09947A template in SRM 2392 and two sites in the HL-60 template in SRM 2392-I. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Standardization of proton-induced x-ray emission technique for analysis of thick samples

    NASA Astrophysics Data System (ADS)

    Ali, Shad; Zeb, Johar; Ahad, Abdul; Ahmad, Ishfaq; Haneef, M.; Akbar, Jehan

    2015-09-01

    This paper describes the standardization of the proton-induced x-ray emission (PIXE) technique for finding the elemental composition of thick samples. For the standardization, three different samples of standard reference materials (SRMs) were analyzed using this technique and the data were compared with the already known data of these certified SRMs. These samples were selected in order to cover the maximum range of elements in the periodic table. Each sample was irradiated for three different values of collected beam charges at three different times. A proton beam of 2.57 MeV obtained using 5UDH-II Pelletron accelerator was used for excitation of x-rays from the sample. The acquired experimental data were analyzed using the GUPIXWIN software. The results show that the SRM data and the data obtained using the PIXE technique are in good agreement.

  4. Development of liquid chromatographic methods for the determination of phytosterols in Standard Reference Materials containing saw palmetto.

    PubMed

    Bedner, Mary; Schantz, Michele M; Sander, Lane C; Sharpless, Katherine E

    2008-05-23

    Liquid chromatographic (LC) methods using atmospheric pressure chemical ionization/mass spectrometric (APCI-MS) detection were developed for the separation and analysis of the phytosterols campesterol, cycloartenol, lupenone, lupeol, beta-sitosterol, and stigmasterol. Brassicasterol and cholesterol were also included for investigation as internal standards. The methods were used to identify and quantify the phytosterols in each of two Serenoa repens (saw palmetto) Standard Reference Materials (SRMs) developed by the National Institute of Standards and Technology (NIST). Values obtained by LC-MS were compared to those obtained using the more traditional approach of gas chromatography with flame ionization detection. This is the first reported use of LC-MS to determine phytosterols in saw palmetto dietary supplement materials.

  5. Certification of the methylmercury content in SRM 2977 mussel tissue (organic contaminants and trace elements) and SRM 1566b oyster tissue.

    PubMed

    Tutschku, S; Schantz, M M; Horvat, M; Logar, M; Akagi, H; Emons, H; Levenson, M; Wise, S A

    2001-02-01

    The methylmercury content in two new marine bivalve mollusk tissue Standard Reference Materials (SRMs) has been certified using results of analyses from the National Institute of Standards and Technology (NIST) and two other laboratories. The certified concentrations of methylmercury were established based on the results from four and six different (independent) analytical methods, respectively, for SRM 1566b Oyster Tissue (13.2 +/- 0.7 microg/kg) and SRM 2977 Mussel Tissue (organic contaminants and trace elements) (36.2 +/- 1.7 microg/kg). The certified concentration of methylmercury in SRM 1566b is among the lowest in any certified reference material (CRM).

  6. A new, high-precision measurement of the X-ray Cu K α spectrum

    NASA Astrophysics Data System (ADS)

    Mendenhall, Marcus H.; Cline, James P.; Henins, Albert; Hudson, Lawrence T.; Szabo, Csilla I.; Windover, Donald

    2016-03-01

    One of the primary measurement issues addressed with NIST Standard Reference Materials (SRMs) for powder diffraction is that of line position. SRMs for this purpose are certified with respect to lattice parameter, traceable to the SI through precise measurement of the emission spectrum of the X-ray source. Therefore, accurate characterization of the emission spectrum is critical to a minimization of the error bounds on the certified parameters. The presently accepted sources for the SI traceable characterization of the Cu K α emission spectrum are those of Härtwig, Hölzer et al., published in the 1990s. The structure of the X-ray emission lines of the Cu K α complex has been remeasured on a newly commissioned double-crystal instrument, with six-bounce Si (440) optics, in a manner directly traceable to the SI definition of the meter. In this measurement, the entire region from 8020 eV to 8100 eV has been covered with a highly precise angular scale and well-defined system efficiency, providing accurate wavelengths and relative intensities. This measurement is in modest disagreement with reference values for the wavelength of the Kα1 line, and strong disagreement for the wavelength of the Kα2 line.

  7. Inorganic chemical analysis of environmental materials—A lecture series

    USGS Publications Warehouse

    Crock, J.G.; Lamothe, P.J.

    2011-01-01

    At the request of the faculty of the Colorado School of Mines, Golden, Colorado, the authors prepared and presented a lecture series to the students of a graduate level advanced instrumental analysis class. The slides and text presented in this report are a compilation and condensation of this series of lectures. The purpose of this report is to present the slides and notes and to emphasize the thought processes that should be used by a scientist submitting samples for analyses in order to procure analytical data to answer a research question. First and foremost, the analytical data generated can be no better than the samples submitted. The questions to be answered must first be well defined and the appropriate samples collected from the population that will answer the question. The proper methods of analysis, including proper sample preparation and digestion techniques, must then be applied. Care must be taken to achieve the required limits of detection of the critical analytes to yield detectable analyte concentration (above "action" levels) for the majority of the study's samples and to address what portion of those analytes answer the research question-total or partial concentrations. To guarantee a robust analytical result that answers the research question(s), a well-defined quality assurance and quality control (QA/QC) plan must be employed. This QA/QC plan must include the collection and analysis of field and laboratory blanks, sample duplicates, and matrix-matched standard reference materials (SRMs). The proper SRMs may include in-house materials and/or a selection of widely available commercial materials. A discussion of the preparation and applicability of in-house reference materials is also presented. Only when all these analytical issues are sufficiently addressed can the research questions be answered with known certainty.

  8. Extraction of organic contaminants from marine sediments and tissues using microwave energy.

    PubMed

    Jayaraman, S; Pruell, R J; McKinney, R

    2001-07-01

    In this study, we compared microwave solvent extraction (MSE) to conventional methods for extracting organic contaminants from marine sediments and tissues with high and varying moisture content. The organic contaminants measured were polychlorinated biphenyl (PCB) congeners, chlorinated pesticides, and polycyclic aromatic hydrocarbons (PAHs). Initial experiments were conducted on dry standard reference materials (SRMs) and field collected marine sediments. Moisture content in samples greatly influenced the recovery of the analytes of interest. When wet sediments were included in a sample batch, low recoveries were often encountered in other samples in the batch, including the dry SRM. Experiments were conducted to test the effect of standardizing the moisture content in all samples in a batch prior to extraction. SRM1941a (marine sediment). SRM1974a (mussel tissue), as well as QA96SED6 (marine sediment), and QA96TIS7 (marine tissue), both from 1996 NIST Intercalibration Exercise were extracted using microwave and conventional methods. Moisture levels were adjusted in SRMs to match those of marine sediment and tissue samples before microwave extraction. The results demonstrated that it is crucial to standardize the moisture content in all samples, including dry reference material to ensure good recovery of organic contaminants. MSE yielded equivalent or superior recoveries compared to conventional methods for the majority of the compounds evaluated. The advantages of MSE over conventional methods are reduced solvent usage, higher sample throughput and the elimination of halogenated solvent usage.

  9. Enantiomer fractions of polychlorinated biphenyls in three selected Standard Reference Materials.

    PubMed

    Morrissey, Joshua A; Bleackley, Derek S; Warner, Nicholas A; Wong, Charles S

    2007-01-01

    The enantiomer composition of six chiral polychlorinated biphenyls (PCBs) were measured in three different certified Standard Reference Materials (SRMs) from the US National Institute of Standards and Technology (NIST): SRM 1946 (Lake Superior fish tissue), SRM 1939a (PCB Congeners in Hudson River Sediment), and SRM 2978 (organic contaminants in mussel tissue--Raritan Bay, New Jersey) to aid in quality assurance/quality control methodologies in the study of chiral pollutants in sediments and biota. Enantiomer fractions (EFs) of PCBs 91, 95, 136, 149, 174, and 183 were measured using a suite of chiral columns by gas chromatography/mass spectrometry. Concentrations of target analytes were in agreement with certified values. Target analyte EFs in reference materials were measured precisely (<2% relative standard deviation), indicating the utility of SRM in quality assurance/control methodologies for analyses of chiral compounds in environmental samples. Measured EFs were also in agreement with previously published analyses of similar samples, indicating that similar enantioselective processes were taking place in these environmental matrices.

  10. 30 CFR 7.507 - Air-monitoring components.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... in mines with a history of harmful gases, other than carbon monoxide, carbon dioxide, and methane... and Technology (NIST) “Standard Reference Materials” (SRMs). (4) The analytical accuracy of the...

  11. Validation studies of Karl Fisher reference method for moisture in cotton

    USDA-ARS?s Scientific Manuscript database

    With current international standard oven drying (SOD) techniques lacking precision and accuracy statements, a new standard reference method is needed. Volumetric Karl Fischer Titration (KFT) is a widely used measure of moisture content. The method is used in many ASTM methods, 14 NIST SRMs, and te...

  12. Establishing the traceability of a uranyl nitrate solution to a standard reference material

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jackson, C.H.; Clark, J.P.

    1978-01-01

    A uranyl nitrate solution for use as a Working Calibration and Test Material (WCTM) was characterized, using a statistically designed procedure to document traceability to National Bureau of Standards Reference Material (SPM-960). A Reference Calibration and Test Material (PCTM) was prepared from SRM-960 uranium metal to approximate the acid and uranium concentration of the WCTM. This solution was used in the characterization procedure. Details of preparing, handling, and packaging these solutions are covered. Two outside laboratories, each having measurement expertise using a different analytical method, were selected to measure both solutions according to the procedure for characterizing the WCTM. Twomore » different methods were also used for the in-house characterization work. All analytical results were tested for statistical agreement before the WCTM concentration and limit of error values were calculated. A concentration value was determined with a relative limit of error (RLE) of approximately 0.03% which was better than the target RLE of 0.08%. The use of this working material eliminates the expense of using SRMs to fulfill traceability requirements for uranium measurements on this type material. Several years' supply of uranyl nitrate solution with NBS traceability was produced. The cost of this material was less than 10% of an equal quantity of SRM-960 uranium metal.« less

  13. Direct Analysis of Low-Volatile Molecular Marker Extract from Airborne Particulate Matter Using Sensitivity Correction Method

    PubMed Central

    Irei, Satoshi

    2016-01-01

    Molecular marker analysis of environmental samples often requires time consuming preseparation steps. Here, analysis of low-volatile nonpolar molecular markers (5-6 ring polycyclic aromatic hydrocarbons or PAHs, hopanoids, and n-alkanes) without the preseparation procedure is presented. Analysis of artificial sample extracts was directly conducted by gas chromatography-mass spectrometry (GC-MS). After every sample injection, a standard mixture was also analyzed to make a correction on the variation of instrumental sensitivity caused by the unfavorable matrix contained in the extract. The method was further validated for the PAHs using the NIST standard reference materials (SRMs) and then applied to airborne particulate matter samples. Tests with the SRMs showed that overall our methodology was validated with the uncertainty of ~30%. The measurement results of airborne particulate matter (PM) filter samples showed a strong correlation between the PAHs, implying the contributions from the same emission source. Analysis of size-segregated PM filter samples showed that their size distributions were found to be in the PM smaller than 0.4 μm aerodynamic diameter. The observations were consistent with our expectation of their possible sources. Thus, the method was found to be useful for molecular marker studies. PMID:27127511

  14. Multilaboratory Validation of First Action Method 2016.04 for Determination of Four Arsenic Species in Fruit Juice by High-Performance Liquid Chromatography-Inductively Coupled Plasma-Mass Spectrometry.

    PubMed

    Kubachka, Kevin; Heitkemper, Douglas T; Conklin, Sean

    2017-07-01

    Before being designated AOAC First Action Official MethodSM 2016.04, the U.S. Food and Drug Administration's method, EAM 4.10 High Performance Liquid Chromatography-Inductively Coupled Plasma-Mass Spectrometric Determination of Four Arsenic Species in Fruit Juice, underwent both a single-laboratory validation and a multilaboratory validation (MLV) study. Three federal and five state regulatory laboratories participated in the MLV study, which is the primary focus of this manuscript. The method was validated for inorganic arsenic (iAs) measured as the sum of the two iAs species arsenite [As(III)] and arsenate [As(V)], dimethylarsinic acid (DMA), and monomethylarsonic acid (MMA) by analyses of 13 juice samples, including three apple juice, three apple juice concentrate, four grape juice, and three pear juice samples. In addition, two water Standard Reference Materials (SRMs) were analyzed. The method LODs and LOQs obtained among the eight laboratories were approximately 0.3 and 2 ng/g, respectively, for each of the analytes and were adequate for the intended purpose of the method. Each laboratory analyzed method blanks, fortified method blanks, reference materials, triplicate portions of each juice sample, and duplicate fortified juice samples (one for each matrix type) at three fortification levels. In general, repeatability and reproducibility of the method was ≤15% RSD for each species present at a concentration >LOQ. The average recovery of fortified analytes for all laboratories ranged from 98 to 104% iAs, DMA, and MMA for all four juice sample matrixes. The average iAs results for SRMs 1640a and 1643e agreed within the range of 96-98% of certified values for total arsenic.

  15. Determination of elemental carbon in lake sediments using a thermal-optical transmittance (TOT) method

    NASA Astrophysics Data System (ADS)

    Khan, A. J.; Swami, Kamal; Ahmed, Tanveer; Bari, A.; Shareef, Akhtar; Husain, Liaquat

    2009-12-01

    An improved chemical oxidation pretreatment method has been developed for the determination of elemental carbon (EC) [also known as black carbon (BC) or soot] in lake sediments, using a thermal-optical transmittance (TOT) carbon analyzer. The method employs six steps: (1) removal of carbonates by treatment with HCl; (2) removal of silicates by treatment with HF + HCl; (3) removal of any remaining carbonates by treatment with HCl; (4) removal of humic acids by treatment with NaOH; and (5) oxidation of kerogens by K 2Cr 2O 7 + H 2SO 4. A critical step of zinc chloride treatment was added; this apparently changes EC's morphology and enhances retention on quartz fiber filter, resulting in several-fold increased chemical yield. EC was determined using the TOT method with modified combustion timings. Carbon black (acetylene) and four NIST standard reference materials (SRMs) were used for quality control, and to assess the precision of the analysis. The EC recoveries from 18 carbon black samples varied from 90 to 111%, with a mean value of 99 ± 6%. The high EC recoveries confirmed the validity of the method. Char reference materials (i.e. chestnut wood and grass char) were used to determine potential contribution to EC in our measurements. The char references containing about 700 mg total organic carbon (OC) contributed ˜1.5% EC. The measured EC values from four NIST standards were 17.0 ± 0.6, 24.2 ± 3.2, 5.6, and 1.9 ± 0.1 mg g dw-1 for SRM-1648, SRM-1649a, SRM-1941b and SRM-8704, respectively. These values in SRMs were in agreement (<±4%) with the previously reported values. The method was applied to determine the EC in sediment cores from an urban lake and a remote mountain lake in the Northeastern United States. The EC concentrations in two lakes mimic the model EC emissions from the industrial revolution in United States.

  16. Comparison of four USEPA digestion methods for trace metal analysis using certified and Florida soils

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, M.; Ma, L.Q.

    1998-11-01

    It is critical to compare existing sample digestion methods for evaluating soil contamination and remediation. USEPA Methods 3050, 3051, 3051a, and 3052 were used to digest standard reference materials and representative Florida surface soils. Fifteen trace metals (Ag, As, Ba, Be, Cd, Cr, Cu, Hg, Mn, Mo, Ni, Pb, Sb, Se, and Za), and six macro elements (Al, Ca, Fe, K, Mg, and P) were analyzed. Precise analysis was achieved for all elements except for Cd, Mo, Se, and Sb in NIST SRMs 2704 and 2709 by USEPA Methods 3050 and 3051, and for all elements except for As, Mo,more » Sb, and Se in NIST SRM 2711 by USEPA Method 3052. No significant differences were observed for the three NIST SRMs between the microwave-assisted USEPA Methods 3051 and 3051A and the conventional USEPA Method 3050 Methods 3051 and 3051a and the conventional USEPA Method 3050 except for Hg, Sb, and Se. USEPA Method 3051a provided comparable values for NIST SRMs certified using USEPA Method 3050. However, for method correlation coefficients and elemental recoveries in 40 Florida surface soils, USEPA Method 3051a was an overall better alternative for Method 3050 than was Method 3051. Among the four digestion methods, the microwave-assisted USEPA Method 3052 achieved satisfactory recoveries for all elements except As and Mg using NIST SRM 2711. This total-total digestion method provided greater recoveries for 12 elements Ag, Be, Cr, Fe, K, Mn, Mo, Ni, Pb, Sb, Se, and Zn, but lower recoveries for Mg in Florida soils than did the total-recoverable digestion methods.« less

  17. 30 CFR 7.507 - Air-monitoring components.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND... in mines with a history of harmful gases, other than carbon monoxide, carbon dioxide, and methane... and Technology (NIST) “Standard Reference Materials” (SRMs). (4) The analytical accuracy of the...

  18. Space Operations Center, shuttle interaction study, volume 1

    NASA Technical Reports Server (NTRS)

    1981-01-01

    The feasibility of the shuttle remote manipulator system (SRMS)-aided space operations center (SOC)/orbiter berthing was evaluated to determine: (1) whether the initial rates between the SOC and the orbiter can be removed by the arm; (2) what is the best strategy to be used; (3) whether the post-capture and maneuvering loads are within the capability of the SRMS; (4) can the SOC berthing port be brought in the immediate proximity of the orbiter berthing port; and (5) what is the best way to remove the residual relative motions. Various notational conventions are established and various important locations on the orbiter and SOC structures are defined. Reference frames are defined together with the mass properties of both the SOC and the orbiter.

  19. Multivariable control of the Space Shuttle Remote Manipulator System using linearization by state feedback

    NASA Technical Reports Server (NTRS)

    Gettman, Chang-Ching L.; Adams, Neil; Bedrossian, Nazareth; Valavani, Lena

    1993-01-01

    This paper demonstrates an approach to nonlinear control system design that uses linearization by state feedback to allow faster maneuvering of payloads by the Shuttle Remote Manipulator System (SRMS). A nonlinear feedback law is defined to cancel the nonlinear plant dynamics so that a linear controller can be designed for the SRMS. First a nonlinear design model was generated via SIMULINK. This design model included nonlinear arm dynamics derived from the Lagrangian approach, linearized servo model, and linearized gearbox model. The current SRMS position hold controller was implemented on this system. Next, a trajectory was defined using a rigid body kinematics SRMS tool, KRMS. The maneuver was simulated. Finally, higher bandwidth controllers were developed. Results of the new controllers were compared with the existing SRMS automatic control modes for the Space Station Freedom Mission Build 4 Payload extended on the SRMS.

  20. Multivariable control of the Space Shuttle remote manipulator system using H2 and H(infinity) optimization. M.S. Thesis - Massachusetts Inst. of Tech.

    NASA Technical Reports Server (NTRS)

    Prakash, OM, II

    1991-01-01

    Three linear controllers are desiged to regulate the end effector of the Space Shuttle Remote Manipulator System (SRMS) operating in Position Hold Mode. In this mode of operation, jet firings of the Orbiter can be treated as disturbances while the controller tries to keep the end effector stationary in an orbiter-fixed reference frame. The three design techniques used include: the Linear Quadratic Regulator (LQR), H2 optimization, and H-infinity optimization. The nonlinear SRMS is linearized by modelling the effects of the significant nonlinearities as uncertain parameters. Each regulator design is evaluated for robust stability in light of the parametric uncertanties using both the small gain theorem with an H-infinity norm and the less conservative micro-analysis test. All three regulator designs offer significant improvement over the current system on the nominal plant. Unfortunately, even after dropping performance requirements and designing exclusively for robust stability, robust stability cannot be achieved. The SRMS suffers from lightly damped poles with real parametric uncertainties. Such a system renders the micro-analysis test, which allows for complex peturbations, too conservative.

  1. Admittance model for the shuttle remote manipulator system in four configurations. M.S. Thesis

    NASA Technical Reports Server (NTRS)

    Papadopoulos, Loukas; Tolson, Robert H.

    1993-01-01

    A possible scenario for robot task performance in space is to mount two small, dexterous arms to the end of the Shuttle Remote Manipulator System (SRMS). As these small robots perform tasks, the flexibility of the SRMS may cause unsuccessful task executions. In order to simulate the dynamic coupling between the SRMS and the arms, admittance models of the SRMS in four brakes locked configurations were developed. The admittance model permits calculation of the SRMS end-effector response due to end-effector disturbing forces. The model will then be used in conjunction with a Stewart Platform, a vehicle emulation system. An application of the admittance model was shown by simulating the disturbing forces using two SRMS payloads, the Dextrous Orbital Servicing System (DOSS) manipulator and DOSS carrying a 1000 lb. cylinder. Mode by mode comparisons were conducted to determine the minimum number of modes required in the admittance model while retaining dynamic fidelity. It was determined that for all four SRMS configurations studied, between 4 and 6 modes of the SRMS structure (depending on the excitation loads) were sufficient to retain tolerance of 0.01 inches and 0.01 deg. These tolerances correspond to the DOSS manipulator carrying no object. When the DOSS carries the 1000 lb. cylinder, between 15 and 20 modes were sufficient, approximately three or four times as many modes as for the unloaded case.

  2. Modifications to the NIST reference measurement procedure (RMP) for the determination of serum glucose by isotope dilution gas chromatography/mass spectrometry.

    PubMed

    Prendergast, Jocelyn L; Sniegoski, Lorna T; Welch, Michael J; Phinney, Karen W

    2010-07-01

    The definitive method (DM), now known as the reference measurement procedure (RMP), for the analysis of glucose in serum was originally published in 1982 by the National Institute of Standards and Technology (NIST). Over the years the method has been subject to a number of modifications to adapt to newer technologies and simplify sample preparation. We discuss here an adaptation of the method associated with serum glucose measurements using a modified isotope dilution gas chromatography/mass spectrometry (ID-GC/MS) method. NIST has used this modified method to certify the concentrations of glucose in SRM 965b, Glucose in Frozen Human Serum, and SRM 1950, Metabolites in Human Plasma. Comparison of results from the revised method with certified values for existing Standard Reference Materials (SRMs) demonstrated that these modifications have not affected the quality of the measurements, giving both good precision and accuracy, while reducing the sample preparation time by a day and a half.

  3. Quantification of Complex Polycyclic Aromatic Hydrocarbon Mixtures in Standard Reference Materials Using GC×GC/ToF-MS

    PubMed Central

    Manzano, Carlos; Hoh, Eunha; Massey Simonich, Staci L.

    2014-01-01

    This research is the first to quantify complex PAH mixtures in NIST SRMs using comprehensive two-dimensional gas chromatography coupled to time-of-flight mass spectrometry (GC×GC/ToF-MS), with and without extract cleanup, and reports previously unidentified PAH isomers in the NIST SRMs. We tested a novel, high orthogonality GC column combination (LC-50×NSP-35), as well as with a commonly used column combination (Rtx-5ms×Rxi-17) for the quantification of a complex mixture of 85 different PAHs, including parent (PAHs), alkyl- (MPAHs), nitro- (NPAHs), oxy- (OPAHs), thio- (SPAHs), bromo- (BrPAHs), and chloro-PAHs (ClPAHs) in extracts from two standard reference materials: NIST SRM1650b (diesel particulate matter), with cleanup and NIST SRM1975 (diesel particulate extract), with and without extract cleanup. The LC-50×NSP-35 column combination resulted in an average absolute percent difference of 33.8%, 62.2% and 30.8% compared to the NIST certified PAH concentrations for NIST SRM1650b, NIST SRM1975 with cleanup and NIST SRM1975 without cleanup, while the Rtx-5ms×Rxi-17 resulted in an absolute percent difference of 38.6%, 67.2% and 79.6% for NIST SRM1650b, NIST SRM1975 with cleanup and NIST SRM1975 without cleanup, respectively. This GC×GC/ToF-MS method increases the number of PAHs detected and quantified in complex environmental extracts using a single chromatographic run. Without clean-up, 7 additional compounds were detected and quantified in NIST SRM1975 using the LC-50×NSP-35 column combination. These results suggest that the use of the LC-50×NSP-35 column combination in GC×GC/ToF-MS not only results in better chromatographic resolution and greater orthogonality for the separation of complex PAH mixtures, but can also be used for the accurate quantification of complex PAH mixtures in environmental extracts without cleanup. PMID:23932031

  4. The role of the real-time simulation facility, SIMFAC, in the design, development and performance verification of the Shuttle Remote Manipulator System (SRMS) with man-in-the-loop

    NASA Technical Reports Server (NTRS)

    Mccllough, J. R.; Sharpe, A.; Doetsch, K. H.

    1980-01-01

    The SIMFAC has played a vital role in the design, development, and performance verification of the shuttle remote manipulator system (SRMS) to be installed in the space shuttle orbiter. The facility provides for realistic man-in-the-loop operation of the SRMS by an operator in the operator complex, a flightlike crew station patterned after the orbiter aft flight deck with all necessary man machine interface elements, including SRMS displays and controls and simulated out-of-the-window and CCTV scenes. The characteristics of the manipulator system, including arm and joint servo dynamics and control algorithms, are simulated by a comprehensive mathematical model within the simulation subsystem of the facility. Major studies carried out using SIMFAC include: SRMS parameter sensitivity evaluations; the development, evaluation, and verification of operating procedures; and malfunction simulation and analysis of malfunction performance. Among the most important and comprehensive man-in-the-loop simulations carried out to date on SIMFAC are those which support SRMS performance verification and certification when the SRMS is part of the integrated orbiter-manipulator system.

  5. Milk and serum standard reference materials for monitoring organic contaminants in human samples.

    PubMed

    Schantz, Michele M; Eppe, Gauthier; Focant, Jean-François; Hamilton, Coreen; Heckert, N Alan; Heltsley, Rebecca M; Hoover, Dale; Keller, Jennifer M; Leigh, Stefan D; Patterson, Donald G; Pintar, Adam L; Sharpless, Katherine E; Sjödin, Andreas; Turner, Wayman E; Vander Pol, Stacy S; Wise, Stephen A

    2013-02-01

    Four new Standard Reference Materials (SRMs) have been developed to assist in the quality assurance of chemical contaminant measurements required for human biomonitoring studies, SRM 1953 Organic Contaminants in Non-Fortified Human Milk, SRM 1954 Organic Contaminants in Fortified Human Milk, SRM 1957 Organic Contaminants in Non-Fortified Human Serum, and SRM 1958 Organic Contaminants in Fortified Human Serum. These materials were developed as part of a collaboration between the National Institute of Standards and Technology (NIST) and the Centers for Disease Control and Prevention (CDC) with both agencies contributing data used in the certification of mass fraction values for a wide range of organic contaminants including polychlorinated biphenyl (PCB) congeners, chlorinated pesticides, polybrominated diphenyl ether (PBDE) congeners, and polychlorinated dibenzo-p-dioxin (PCDD) and dibenzofuran (PCDF) congeners. The certified mass fractions of the organic contaminants in unfortified samples, SRM 1953 and SRM 1957, ranged from 12 ng/kg to 2200 ng/kg with the exception of 4,4'-DDE in SRM 1953 at 7400 ng/kg with expanded uncertainties generally <14 %. This agreement suggests that there were no significant biases existing among the multiple methods used for analysis.

  6. Milk and serum standard reference materials for monitoring organic contaminants in human samples

    PubMed Central

    Eppe, Gauthier; Focant, Jean-François; Hamilton, Coreen; Heckert, N. Alan; Heltsley, Rebecca M.; Hoover, Dale; Keller, Jennifer M.; Leigh, Stefan D.; Patterson, Donald G.; Pintar, Adam L.; Sharpless, Katherine E.; Sjödin, Andreas; Turner, Wayman E.; Vander Pol, Stacy S.; Wise, Stephen A.

    2016-01-01

    Four new Standard Reference Materials (SRMs) have been developed to assist in the quality assurance of chemical contaminant measurements required for human biomonitoring studies, SRM 1953 Organic Contaminants in Non-Fortified Human Milk, SRM 1954 Organic Contaminants in Fortified Human Milk, SRM 1957 Organic Contaminants in Non-Fortified Human Serum, and SRM 1958 Organic Contaminants in Fortified Human Serum. These materials were developed as part of a collaboration between the National Institute of Standards and Technology (NIST) and the Centers for Disease Control and Prevention (CDC) with both agencies contributing data used in the certification of mass fraction values for a wide range of organic contaminants including polychlorinated biphenyl (PCB) congeners, chlorinated pesticides, polybrominated diphenyl ether (PBDE) congeners, and polychlorinated dibenzo-p-dioxin (PCDD) and dibenzofuran (PCDF) congeners. The certified mass fractions of the organic contaminants in unfortified samples, SRM 1953 and SRM 1957, ranged from 12 ng/kg to 2200 ng/kg with the exception of 4,4′-DDE in SRM 1953 at 7400 ng/kg with expanded uncertainties generally <14 %. This agreement suggests that there were no significant biases existing among the multiple methods used for analysis. PMID:23132544

  7. Small renal mass biopsy--how, what and when: report from an international consensus panel.

    PubMed

    Tsivian, Matvey; Rampersaud, Edward N; del Pilar Laguna Pes, Maria; Joniau, Steven; Leveillee, Raymond J; Shingleton, William B; Aron, Monish; Kim, Charles Y; DeMarzo, Angelo M; Desai, Mihir M; Meler, James D; Donovan, James F; Klingler, Hans Christoph; Sopko, David R; Madden, John F; Marberger, Michael; Ferrandino, Michael N; Polascik, Thomas J

    2014-06-01

    To discuss the use of renal mass biopsy (RMB) for small renal masses (SRMs), formulate technical aspects, outline potential pitfalls and provide recommendations for the practicing clinician. The meeting was conducted as an informal consensus process and no scoring system was used to measure the levels of agreement on the different topics. A moderated general discussion was used as the basis for consensus and arising issues were resolved at this point. A consensus was established and lack of agreement to topics or specific items was noted at this point. Recommended biopsy technique: at least two cores, sampling different tumour regions with ultrasonography being the preferred method of image guidance. Pathological interpretation: 'non-diagnostic samples' should refer to insufficient material, inconclusive and normal renal parenchyma. For non-diagnostic samples, a repeat biopsy is recommended. Fine-needle aspiration may provide additional information but cannot substitute for core biopsy. Indications for RMB: biopsy is recommended in most cases except in patients with imaging or clinical characteristics indicative of pathology (syndromes, imaging characteristics) and cases whereby conservative management is not contemplated. RMB is recommended for active surveillance but not for watchful-waiting candidates. We report the results of an international consensus meeting on the use of RMB for SRMs, defining the technique, pathological interpretation and indications. © 2013 The Authors. BJU International © 2013 BJU International.

  8. Catalytic spectrophotometric determination of iodine in coal by pyrohydrolysis decomposition.

    PubMed

    Wu, Daishe; Deng, Haiwen; Wang, Wuyi; Xiao, Huayun

    2007-10-10

    A method for the determination of iodine in coal using pyrohydrolysis for sample decomposition was proposed. A pyrohydrolysis apparatus system was constructed, and the procedure was designed to burn and hydrolyse coal steadily and completely. The parameters of pyrohydrolysis were optimized through the orthogonal experimental design. Iodine in the absorption solution was evaluated by the catalytic spectrophotometric method, and the absorbance at 420 nm was measured by a double-beam UV-visible spectrophotometer. The limit of detection and quantification of the proposed method were 0.09 microg g(-1) and 0.29 microg g(-1), respectively. After analysing some Chinese soil reference materials (SRMs), a reasonable agreement was found between the measured values and the certified values. The accuracy of this approach was confirmed by the analysis of eight coals spiked with SRMs with an indexed recovery from 94.97 to 109.56%, whose mean value was 102.58%. Six repeated tests were conducted for eight coal samples, including high sulfur coal and high fluorine coal. A good repeatability was obtained with a relative standard deviation value from 2.88 to 9.52%, averaging 5.87%. With such benefits as simplicity, precision, accuracy and economy, this approach can meet the requirements of the limits of detection and quantification for analysing iodine in coal, and hence it is highly suitable for routine analysis.

  9. Geochemical analysis of soils and sediments, Coeur d'Alene drainage basin, Idaho: sampling, analytical methods, and results

    USGS Publications Warehouse

    Box, Stephen E.; Bookstrom, Arthur A.; Ikramuddin, Mohammed; Lindsay, James

    2001-01-01

    (Fe), manganese (Mn), arsenic (As), and cadmium (Cd). In general inter-laboratory correlations are better for samples within the compositional range of the Standard Reference Materials (SRMs) from the National Institute of Standards and Technology (NIST). Analyses by EWU are the most accurate relative to the NIST standards (mean recoveries within 1% for Pb, Fe, Mn, and As, 3% for Zn and 5% for Cd) and are the most precise (within 7% of the mean at the 95% confidence interval). USGS-EDXRF is similarly accurate for Pb and Zn. XRAL and ACZ are relatively accurate for Pb (within 5-8% of certified NIST values), but were considerably less accurate for the other 5 elements of concern (10-25% of NIST values). However, analyses of sample splits by more than one laboratory reveal that, for some elements, XRAL (Pb, Mn, Cd) and ACZ (Pb, Mn, Zn, Fe) analyses were comparable to EWU analyses of the same samples (when values are within the range of NIST SRMs). These results suggest that, for some elements, XRAL and ACZ dissolutions are more effective on the matrix of the CdA samples than on the matrix of the NIST samples (obtained from soils around Butte, Montana). Splits of CdA samples analyzed by CHEMEX were the least accurate, yielding values 10-25% less than those of EWU.

  10. Real-Time X-ray Radiography Diagnostics of Components in Solid Rocket Motors

    NASA Technical Reports Server (NTRS)

    Cortopassi, A. C.; Martin, H. T.; Boyer, E.; Kuo, K. K.

    2012-01-01

    Solid rocket motors (SRMs) typically use nozzle materials which are required to maintain their shape as well as insulate the underlying support structure during the motor operation. In addition, SRMs need internal insulation materials to protect the motor case from the harsh environment resulting from the combustion of solid propellant. In the nozzle, typical materials consist of high density graphite, carbon-carbon composites and carbon phenolic composites. Internal insulation of the motor cases is typically a composite material with carbon, asbestos, Kevlar, or silica fibers in an ablative matrix such as EPDM or NBR. For both nozzle and internal insulation materials, the charring process occurs when the hot combustion products heat the material intensely. The pyrolysis of the matrix material takes away a portion of the thermal energy near the wall surface and leaves behind a char layer. The fiber reinforcement retains the porous char layer which provides continued thermal protection from the hot combustion products. It is of great interest to characterize both the total erosion rates of the material and the char layer thickness. By better understanding of the erosion process for a particular ablative material in a specific flow environment, the required insulation material thickness can be properly selected. The recession rates of internal insulation and nozzle materials of SRMs are typically determined by testing in some sort of simulated environment; either arc-jet testing, flame torch testing, or subscale SRMs of different size. Material recession rates are deduced by comparison of pre- and post-test measurements and then averaging over the duration of the test. However, these averaging techniques cannot be used to determine the instantaneous recession rates of the material. Knowledge of the variation in recession rates in response to the instantaneous flow conditions during the motor operation is of great importance. For example, in many SRM configurations the recession of the solid propellant grain can drastically alter the flow-field and effect the recession of internal insulation and nozzle materials. Simultaneous measurement of the overall erosion rate, the development of the char layer, and the recession of the char-virgin interface during the motor operation can be rather difficult. While invasive techniques have been used with limited success, they have serious drawbacks. Break wires or make wire sensors can be installed into a sufficient number of locations in the charring material from which a time history of the charring surface can be deduced. These sensors fundamentally alter the local structure of the material in which they are imbedded. Also, the location of these sensors within the material is not known precisely without the use of an X-ray. To determine instantaneous recession rates, real-time X-ray radiography (X-ray RTR) has been utilized in several SRM experiments at PSU. The X-ray RTR system discussed in this paper consists of an X-ray source, X-ray image intensifier, and CCD camera connected to a capture computer. The system has been used to examine the ablation process of internal insulation as well as nozzle material erosion in a subscale SRM. The X-ray source is rated to 320 kV at 10 mA and has both a large (5.5 mm) and small (3.0 mm) focal spot. The lead-lined cesium iodide X-ray image intensifier produces an image which is captured by a CCD camera with a 1,000 x 1,000 pixel resolution. To produce accurate imagery of the object of interest, the alignment of the X-ray source to the X-ray image intensifier is crucial. The image sequences captured during the operation of an SRM are then processed to enhance the quality of the images. This procedure allows for computer software to extract data on the total erosion rate and the char layer thickness. Figure 1 Error! Reference source not found.shows a sequence of images captured during the operation the subscale SRM with the X-ray RTR system. The X-rayTR system, alignment procedure, uncertainty determination, and image analysis process will be discussed in detail in the full manuscript.

  11. Multi-class, multi-residue analysis of pesticides, polychlorinated biphenyls, polycyclic aromatic hydrocarbons, polybrominated diphenyl ethers and novel flame retardants in fish using fast, low-pressure gas chromatography-tandem mass spectrometry.

    PubMed

    Sapozhnikova, Yelena; Lehotay, Steven J

    2013-01-03

    A multi-class, multi-residue method for the analysis of 13 novel flame retardants, 18 representative pesticides, 14 polychlorinated biphenyl (PCB) congeners, 16 polycyclic aromatic hydrocarbons (PAHs), and 7 polybrominated diphenyl ether (PBDE) congeners in catfish muscle was developed and evaluated using fast low pressure gas chromatography triple quadrupole tandem mass spectrometry (LP-GC/MS-MS). The method was based on a QuEChERS (quick, easy, cheap, effective, rugged, safe) extraction with acetonitrile and dispersive solid-phase extraction (d-SPE) clean-up with zirconium-based sorbent prior to LP-GC/MS-MS analysis. The developed method was evaluated at 4 spiking levels and further validated by analysis of NIST Standard Reference Materials (SRMs) 1974B and 1947. Sample preparation for a batch of 10 homogenized samples took about 1h/analyst, and LP-GC/MS-MS analysis provided fast separation of multiple analytes within 9min achieving high throughput. With the use of isotopically labeled internal standards, recoveries of all but one analyte were between 70 and 120% with relative standard deviations less than 20% (n=5). The measured values for both SRMs agreed with certified/reference values (72-119% accuracy) for the majority of analytes. The detection limits were 0.1-0.5ng g(-1) for PCBs, 0.5-10ng g(-1) for PBDEs, 0.5-5ng g(-1) for select pesticides and PAHs and 1-10ng g(-1) for flame retardants. The developed method was successfully applied for analysis of catfish samples from the market. Published by Elsevier B.V.

  12. How sulphate-reducing microorganisms cope with stress: Lessons from systems biology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhou, J.; He, Q.; Hemme, C.L.

    2011-04-01

    Sulphate-reducing microorganisms (SRMs) are a phylogenetically diverse group of anaerobes encompassing distinct physiologies with a broad ecological distribution. As SRMs have important roles in the biogeochemical cycling of carbon, nitrogen, sulphur and various metals, an understanding of how these organisms respond to environmental stresses is of fundamental and practical importance. In this Review, we highlight recent applications of systems biology tools in studying the stress responses of SRMs, particularly Desulfovibrio spp., at the cell, population, community and ecosystem levels. The syntrophic lifestyle of SRMs is also discussed, with a focus on system-level analyses of adaptive mechanisms. Such information is importantmore » for understanding the microbiology of the global sulphur cycle and for developing biotechnological applications of SRMs for environmental remediation, energy production, biocorrosion control, wastewater treatment and mineral recovery.« less

  13. The Optics and Alignment of the Divergent Beam Laboratory X-ray Powder Diffractometer and its Calibration Using NIST Standard Reference Materials.

    PubMed

    Cline, James P; Mendenhall, Marcus H; Black, David; Windover, Donald; Henins, Albert

    2015-01-01

    The laboratory X-ray powder diffractometer is one of the primary analytical tools in materials science. It is applicable to nearly any crystalline material, and with advanced data analysis methods, it can provide a wealth of information concerning sample character. Data from these machines, however, are beset by a complex aberration function that can be addressed through calibration with the use of NIST Standard Reference Materials (SRMs). Laboratory diffractometers can be set up in a range of optical geometries; considered herein are those of Bragg-Brentano divergent beam configuration using both incident and diffracted beam monochromators. We review the origin of the various aberrations affecting instruments of this geometry and the methods developed at NIST to align these machines in a first principles context. Data analysis methods are considered as being in two distinct categories: those that use empirical methods to parameterize the nature of the data for subsequent analysis, and those that use model functions to link the observation directly to a specific aspect of the experiment. We consider a multifaceted approach to instrument calibration using both the empirical and model based data analysis methods. The particular benefits of the fundamental parameters approach are reviewed.

  14. EELV Booster Assist Options for CEV

    NASA Technical Reports Server (NTRS)

    McNeal, Curtis, Jr.

    2005-01-01

    Medium lift EELVs may still play a role in manned space flight. To be considered for manned flight, medium lift EELVs must address the short comings in their current boost assist motors. Two options exist: redesign and requalify the solid rocket motors. Replace solid rocket motors (SRMs) with hybrid rocket motors. Hybrid rocket motors are an attractive alternative. They are safer than SRMs. The TRL's Lockheed Martin Small Launch Vehicle booster development substantially lowers the development risk, cost risk, and the schedule risk for developing hybrid boost assist for EELVs. Hybrid boosters testability offsets SRMs higher inherent reliability.Hybrid booster development and recurring costs are lower than SRMs. Performance gains are readily achieved.

  15. Autoclave decomposition method for metals in soils and sediments.

    PubMed

    Navarrete-López, M; Jonathan, M P; Rodríguez-Espinosa, P F; Salgado-Galeana, J A

    2012-04-01

    Leaching of partially leached metals (Fe, Mn, Cd, Co, Cu, Ni, Pb, and Zn) was done using autoclave technique which was modified based on EPA 3051A digestion technique. The autoclave method was developed as an alternative to the regular digestion procedure passed the safety norms for partial extraction of metals in polytetrafluoroethylene (PFA vessel) with a low constant temperature (119.5° ± 1.5°C) and the recovery of elements were also precise. The autoclave method was also validated using two Standard Reference Materials (SRMs: Loam Soil B and Loam Soil D) and the recoveries were equally superior to the traditionally established digestion methods. Application of the autoclave was samples from different natural environments (beach, mangrove, river, and city soil) to reproduce the recovery of elements during subsequent analysis.

  16. Determination of polychlorinated biphenyl congeners and chlorinated pesticides in a fish tissue standard reference material.

    PubMed

    Poster, Dianne L; Kucklick, John R; Schantz, Michele M; Porter, Barbara J; Leigh, Stefan D; Wise, Stephen A

    2003-01-01

    The concentrations of a wide range of polychlorinated biphenyl congeners (PCBs) and chlorinated pesticides in a fish tissue Standard Reference Material (SRM) have been determined using multiple methods of analysis. This material, SRM 1946, Lake Superior Fish Tissue, was recently issued by the National Institute of Standards and Technology (NIST) and complements a suite of marine environmental natural-matrix SRMs that are currently available from NIST for the determination of organic contaminants such as aliphatic hydrocarbons, polycyclic aromatic hydrocarbons (PAHs), PCBs, and chlorinated pesticides. SRM 1946 is a fresh tissue homogenate (frozen) prepared from filleted adult lake trout (Salvelinus namaycush namaycush) collected from the Apostle Islands region of Lake Superior. SRM 1946 has certified and reference concentrations for PCB congeners, including the three non- ortho PCB congeners, and chlorinated pesticides. Certified concentrations are available for 30 PCB congeners and 15 chlorinated pesticides. Reference concentrations are available for 12 PCB congeners and 2 chlorinated pesticides. In addition, SRM 1946 is characterized for additional chemical constituents and properties: fatty acids, extractable fat, methylmercury, total mercury, selected trace elements, proximates, and caloric content. The characterization of chlorinated compounds is described in this paper with an emphasis on the approach used for the certification of the concentrations of PCB congeners and chlorinated pesticides. The PCB congener and chlorinated pesticide data are also compared to concentrations in other marine natural-matrix reference materials available from NIST (fish oil, mussel tissue, whale blubber, and a second fresh frozen fish tissue homogenate prepared from filleted adult lake trout collected from Lake Michigan) and from other organizations such as the National Research Council Canada (ground whole carp), the International Atomic Energy Agency (fish homogenate), and the European Commission Joint Research Centre [fish oils (cod and mackerel) and mussel tissue].

  17. Quality Assurance of Chemical Measurements.

    ERIC Educational Resources Information Center

    Taylor, John K.

    1981-01-01

    Reviews aspects of quality control (methods to control errors) and quality assessment (verification that systems are operating within acceptable limits) including an analytical measurement system, quality control by inspection, control charts, systematic errors, and use of SRMs, materials for which properties are certified by the National Bureau…

  18. Value assignment of nutrient concentrations in five standard reference materials and six reference materials.

    PubMed

    Sharpless, K E; Gill, L M

    2000-01-01

    A number of food-matrix reference materials (RMs) are available from the National Institute of Standards and Technology (NIST) and from Agriculture Canada through NIST. Most of these materials were originally value-assigned for their elemental composition (major, minor, and trace elements), but no additional nutritional information was provided. Two of the materials were certified for selected organic constituents. Ten of these materials (Standard Reference Material [SRM] 1,563 Cholesterol and Fat-Soluble Vitamins in Coconut Oil [Natural and Fortified], SRM 1,566b Oyster Tissue, SRM 1,570a Spinach Leaves, SRM 1,974a Organics in Mussel Tissue (Mytilus edulis), RM 8,415 Whole Egg Powder, RM 8,418 Wheat Gluten, RM 8,432 Corn Starch, RM 8,433 Corn Bran, RM 8,435 Whole Milk Powder, and RM 8,436 Durum Wheat Flour) were recently distributed by NIST to 4 laboratories with expertise in food analysis for the measurement of proximates (solids, fat, protein, etc.), calories, and total dietary fiber, as appropriate. SRM 1846 Infant Formula was distributed as a quality control sample for the proximates and for analysis for individual fatty acids. Two of the materials (Whole Egg Powder and Whole Milk Powder) were distributed in an earlier interlaboratory comparison exercise in which they were analyzed for several vitamins. Value assignment of analyte concentrations in these 11 SRMs and RMs, based on analyses by the collaborating laboratories, is described in this paper. These materials are intended primarily for validation of analytical methods for the measurement of nutrients in foods of similar composition (based on AOAC INTERNATIONAL's fat-protein-carbohydrate triangle). They may also be used as "primary control materials" in the value assignment of in-house control materials of similar composition. The addition of proximate information for 10 existing reference materials means that RMs are now available from NIST with assigned values for proximates in 6 of the 9 sectors of the AOAC triangle. Five of these materials have values assigned for total dietary fiber-the first such information provided for materials available from NIST.

  19. The determination of water in crude oil and transformer oil reference materials.

    PubMed

    Margolis, Sam A; Hagwood, Charles

    2003-05-01

    The measurement of the amount of water in oils is of significant economic importance to the industrial community, particularly to the electric power and crude oil industries. The amount of water in transformer oils is critical to their normal function and the amount of water in crude oils affects the cost of the crude oil at the well head, the pipeline, and the refinery. Water in oil Certified Reference Materials (CRM) are essential for the accurate calibration of instruments that are used by these industries. Three NIST Standard Reference Materials (SRMs) have been prepared for this purpose. The water in these oils has been measured by both coulometric and volumetric Karl Fischer methods. The compounds (such as sulfur compounds) that interfere with the Karl Fischer reaction (interfering substances) and inflate the values for water by also reacting with iodine have been measured coulometrically. The measured water content of Reference Material (RM) 8506a Transformer Oil is 12.1+/-1.9 mg kg(-1) (plus an additional 6.2+/-0.9 mg kg(-1) of interfering substances). The measured water content of SRM 2722 Sweet Crude Oil, is 99+/-6 mg kg(-1) (plus an additional 5+/-2 mg kg(-1) of interfering substances). The measured water content of SRM 2721 Sour Crude Oil, is 134+/-18 mg kg(-1) plus an additional 807+/-43 mg kg(-1) of interfering substances. Interlaboratory studies conducted with these oil samples (using SRM 2890, water saturated 1-octanol, as a calibrant) are reported. Some of the possible sources of bias in these measurements were identified, These include: improperly calibrated instruments, inability to measure the calibrant accurately, Karl Fischer reagent selection, and volatilization of the interfering substances in SRM 2721.

  20. The NIST radioactivity measurement assurance program for the radiopharmaceutical industry.

    PubMed

    Cessna, Jeffrey T; Golas, Daniel B

    2012-09-01

    The National Institute of Standards and Technology (NIST) maintains a program for the establishment and dissemination of activity measurement standards in nuclear medicine. These standards are disseminated through Standard Reference Materials (SRMs), Calibration Services, radionuclide calibrator settings, and the NIST Radioactivity Measurement Assurance Program (NRMAP, formerly the NEI/NIST MAP). The MAP for the radiopharmaceutical industry is described here. Consolidated results show that, for over 3600 comparisons, 96% of the participants' results differed from that of NIST by less than 10%, with 98% being less than 20%. Individual radionuclide results are presented from 214 to 439 comparisons, per radionuclide, for (67)Ga, (90)Y, (99m)Tc, (99)Mo, (111)In, (125)I, (131)I, and (201)Tl. The percentage of participants results within 10% of NIST ranges from 88% to 98%. Published by Elsevier Ltd.

  1. Storage resource manager

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Perelmutov, T.; Bakken, J.; Petravick, D.

    Storage Resource Managers (SRMs) are middleware components whose function is to provide dynamic space allocation and file management on shared storage components on the Grid[1,2]. SRMs support protocol negotiation and reliable replication mechanism. The SRM standard supports independent SRM implementations, allowing for a uniform access to heterogeneous storage elements. SRMs allow site-specific policies at each location. Resource Reservations made through SRMs have limited lifetimes and allow for automatic collection of unused resources thus preventing clogging of storage systems with ''orphan'' files. At Fermilab, data handling systems use the SRM management interface to the dCache Distributed Disk Cache [5,6] and themore » Enstore Tape Storage System [15] as key components to satisfy current and future user requests [4]. The SAM project offers the SRM interface for its internal caches as well.« less

  2. Biological and environmental reference materials in CENAM.

    PubMed

    Arvizu-Torres, R; Perez-Castorena, A; Salas-Tellez, J A; Mitani-Nakanishi, Y

    2001-06-01

    Since 1994, when the NIST/NOAA Quality Assurance Program in Chemical Measurements was discussed in Queretaro, CENAM, the National Measurement Institute (NMI) of Mexico, has become involved in the development of reference materials. In the field of biological and environmental reference materials, in particular, the NORAMET collaboration program with NIST and NRC, and the North-American Environmental Cooperation signed among three free-trade treaty organizations, have greatly helped the development of the materials metrology program in the newly established CENAM. This paper describes some particularly significant efforts of CENAM in the development of biological and environmental reference materials, on the basis of inter-comparison studies organized with local and governmental environmental agencies of Mexico. In the field of water pollution CENAM has developed a practical proficiency testing (PT) scheme for field laboratories, as a part of registration by local government in the metropolitan area, according to the Mexican Ecological Regulation. The results from these eight PTs in the last 5 years have demonstrated that this scheme has helped ensure the reliability of analytical capability of more than 50 field laboratories in three states, Mexico, D.F., and the States of Mexico and Queretaro. Similar experience has been obtained for more than 70 service units of stack emission measurements in the three states in 1998 and 1999, as a result of the design of a PT scheme for reference gas mixtures. This PT scheme has been accomplished successfully by 30 analytical laboratories who provide monitoring services and perform research on toxic substances (Hg, methylmercury, PCB, etc.) in Mexico. To support these activities, reference samples have been produced through the NIST SRMs, and efforts have been made to increase CENAM's capability in the preparation of primary reference materials in spectrometric solutions and gas mixtures. Collaboration among NMIs has also successfully overcome the inability of CENAM to prepare biological tissue for mercury assessment and marine sediments for analysis of trace metals. The importance of international collaboration is stressed not only in the NORAMET region but also in the SIM, to provide help for each other and achieve mutual recognition among member countries of the region.

  3. Optical droplet vaporization of nanoparticle-loaded stimuli-responsive microbubbles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Si, Ting; Department of Biomedical Engineering, The Ohio State University, Columbus, Ohio 43210; Li, Guangbin

    2016-03-14

    A capillary co-flow focusing process is developed to generate stimuli-responsive microbubbles (SRMs) that comprise perfluorocarbon (PFC) suspension of silver nanoparticles (SNPs) in a lipid shell. Upon continuous laser irradiation at around their surface plasmon resonance band, the SNPs effectively absorb electromagnetic energy, induce heat accumulation in SRMs, trigger PFC vaporization, and eventually lead to thermal expansion and fragmentation of the SRMs. This optical droplet vaporization (ODV) process is further simulated by a theoretical model that combines heat generation of SNPs, phase change of PFC, and thermal expansion of SRMs. The model is validated by benchtop experiments, where the ODV processmore » is monitored by microscopic imaging. The effects of primary process parameters on behaviors of ODV are predicted by the theoretical model, indicating the technical feasibility for process control and optimization in future drug delivery applications.« less

  4. Thrust imbalance of the Space Shuttle solid rocket motors

    NASA Technical Reports Server (NTRS)

    Foster, W. A., Jr.; Sforzini, R. H.; Shackelford, B. W., Jr.

    1981-01-01

    The Monte Carlo statistical analysis of thrust imbalance is applied to both the Titan IIIC and the Space Shuttle solid rocket motors (SRMs) firing in parallel, and results are compared with those obtained from the Space Shuttle program. The test results are examined in three phases: (1) pairs of SRMs selected from static tests of the four developmental motors (DMs 1 through 4); (2) pairs of SRMs selected from static tests of the three quality assurance motors (QMs 1 through 3); (3) SRMs on the first flight test vehicle (STS-1A and STS-1B). The simplified internal ballistic model utilized for computing thrust from head-end pressure measurements on flight tests is shown to agree closely with measured thrust data. Inaccuracies in thrust imbalance evaluation are explained by possible flight test instrumentation errors.

  5. Microwave-assisted extraction and quantitative LC/ID-MS measurement of total choline and free carnitine in food standard reference materials.

    PubMed

    Phillips, Melissa M; Sander, Lane C

    2012-01-01

    The Stakeholder Panel on Infant Formula and Adult Nutritionals of AOAC INTERNATIONAL has declared both choline and carnitine to be priority nutrients in infant formulas, and ongoing efforts exist to develop or improve Official Methods of Analysis for these nutrients. As a result, matrix-based certified reference materials are needed with assigned values for these compounds. In this work, traditional acid and enzymatic hydrolysis procedures were compared to microwave-assisted acid hydrolysis, and conditions optimized to provide complete sample hydrolysis and recovery of total choline from four food standard reference materials (SRMs): whole milk powder, whole egg powder, infant formula, and soy flour. The extracts were analyzed using LC on a mixed-mode column (simultaneous RP and ion exchange) with isotope dilution-MS detection to achieve simultaneous quantification of total choline and free carnitine. Total choline has been determined in these four food matrixes with excellent precision (0.65 to 2.60%) and accuracy, as confirmed by use of SRM 1849 Infant/Adult Nutritional Formula as a control material. Free carnitine has been determined in two of these food matrixes with excellent precision (0.69 to 2.19%) and accuracy, as confirmed by use of SRM 1849 Infant/Adult Nutritional Formula as a control material. Limitations in simultaneous determination of total choline and free carnitine resulted from extreme differences in concentration of the two components in egg powder and soy flour (at least three orders of magnitude). Samples required dilution to prevent poor LC peak shape, which caused decreased precision in the determination of low concentrations of free carnitine. Despite this limitation, the described method yields results comparable to current AOAC Official Method 999.14 Choline in Infant Formula, with a decrease of more than 2 h in sample preparation time.

  6. SRMS Assisted Docking and Undocking for the Orbiter Repair Maneuver

    NASA Technical Reports Server (NTRS)

    Quiocho, Leslie J.; Briscoe, Timothy J.; Schliesing, John A.; Braman, Julia M.

    2005-01-01

    As part of the Orbiter Repair Maneuver (ORM) planned for Return to Flight (RTF) operations, the Shuttle Remote Manipulator System (SRMS) must undock the Orbiter, maneuver it through a complex trajectory at extremely low rates, present it to an EVA crewman at the end of the Space Station Remote Manipulator System to perform the Thermal Protection System (TPS) repair, and then retrace back through the trajectory to dock the Orbiter with the Orbiter Docking System (ODs). The initial and final segments of this operation involve the interaction between the SRMS, ISS, Orbiter and ODs. This paper first provides an overview of the Monte-Carlo screening analysis for the installation (both nominal and contingency), including the variation of separation distance, misalignment conditions, SRMS joint/brake parameter characteristics, and PRCS jet combinations and corresponding thrust durations. The resulting 'optimum' solution is presented based on trade studies between predicted capture success and integrated system loads. This paper then discusses the upgrades to the APAS math model associated with the new SRMS assisted undocking technique and reviews simulation results for various options investigated for either the active and passive separation of the ISS from the Orbiter.

  7. JCPDS-ICDD Research Associateship (Cooperative Program with NBS/NIST)

    PubMed Central

    Wong-Ng, W.; McMurdie, H. F.; Hubbard, C. R.; Mighell, A. D.

    2001-01-01

    The Research Associateship program of the Joint Committee on Powder Diffraction-International Centre for Diffraction Data (JCPDS-ICDD, now known as the ICDD) at NBS/NIST was a long standing (over 35 years) successful industry-government cooperation. The main mission of the Associateship was to publish high quality x-ray reference patterns to be included in the Powder Diffraction File (PDF). The PDF is a continuing compilation of patterns gathered from many sources, compiled and published by the ICDD. As a result of this collaboration, more than 1500 high quality powder diffraction patterns, which have had a significant impact on the scientific community, were reported. In addition, various research collaborations with NBS/NIST also led to the development of several standard reference materials (SRMs) for instrument calibration and quantitative analyses, and computer software for data collection, calibration, reduction, for the editorial process of powder pattern publication, analysis of powder data, and for quantitative analyses. This article summarizes information concerning the JCPDS-ICDD organization, the Powder Diffraction File (PDF), history and accomplishments of the JCPDS-ICDD Research Associateship. PMID:27500061

  8. SRMS History, Evolution and Lessons Learned

    NASA Technical Reports Server (NTRS)

    Jorgensen, Glenn; Bains, Elizabeth

    2011-01-01

    Early in the development of the Space Shuttle, it became clear that NASA needed a method of deploying and retrieving payloads from the payload bay. The Shuttle Remote Manipulator System (SRMS) was developed to fill this need. The 50 foot long robotic arm is an anthropomorphic design consisting of three electromechanical joints, six degrees of freedom, and two boom segments. Its composite boom construction provided a light weight solution needed for space operations. Additionally, a method of capturing payloads with the arm was required and a unique End Effector was developed using an electromechanical snare mechanism. The SRMS is operated using a Displays and Controls Panel and hand controllers located within the aft crew compartment of the shuttle. Although the SRMS was originally conceived to deploy and retrieve payloads, its generic capabilities allowed it to perform many other functions not originally conceived of. Over the years it has been used for deploying and retrieving constrained and free flying payloads, maneuvering and supporting EVA astronauts, satellite repair, International Space Station construction, and as a viewing aid for on-orbit International Space Station operations. After the Columbia accident, a robotically compatible Orbiter Boom Sensor System (OBSS) was developed and used in conjunction with the SRMS to scan the Thermal Protection System (TPS) of the shuttle. These scans ensure there is not a breach of the TPS prior to shuttle re-entry. Ground operations and pre mission simulation, analysis and planning played a major role in the success of the SRMS program. A Systems Engineering Simulator (SES) was developed to provide a utility complimentary to open loop engineering simulations. This system provided a closed-loop real-time pilot-driven simulation giving visual feedback, display and control panel interaction, and integration with other vehicle systems, such as GN&C. It has been useful for many more applications than traditional training. Evolution of the simulations, guided by the Math Model Working Group, showed the utility of input from multiple modeling groups with a structured forum for discussion.There were many unique development challenges in the areas of hardware, software, certification, modeling and simulation. Over the years, upgrades and enhancements were implemented to increase the capability, performance and safety of the SRMS. The history and evolution of the SRMS program provided many lessons learned that can be used for future space robotic systems.

  9. Multielemental analysis in small amounts of environmental reference materials with inductively coupled plasma mass spectrometry.

    PubMed

    Dombovári, J; Becker, J S; Dietze, H J

    2000-07-01

    The lowest possible sample weight for performing multielemental trace element analysis on environmental and biological samples by ICP-MS has been investigated. The certified reference materials Bovine Liver NIST SRM 1577b, Human Hair NCS DC 73347 and Oriental Tobacco Leaves CTA-OTL-1 were applied at sample weights (1, 5, 20 and 50 mg aliquots, n = 10) which were significantly lower than those recommended with most recoveries in the range of 95-110%. Samples were digested in a mixture of nitric acid, hydrogen peroxide and hydrogen fluoride by closed-vessel microwave digestion. Multielemental analysis was performed with an optimized ICP-QMS method. Aqueous standard solutions were applied for external calibration with rhodium as the internal standard element. The detection limits varied between 0.02-0.38 microg/g for Li, Na, Cr, Mn, Ni, Cu, Zn, Sr, Cd, Ba and Pb, and up to 1.92 microg/g for Mg, Al, Ca, Fe and Ni. Digested human plasma samples were spiked with multielemental solution (0.5-10 microg/L) to test the analytical method and the recoveries were 95-105% for most analytes. Our results show that in the case of homogeneous SRMs it is possible to use them in very low amounts (1-5 mg) for method development and quality control.

  10. Integrated Simulation Design Challenges to Support TPS Repair Operations

    NASA Technical Reports Server (NTRS)

    Quiocho, Leslie J.; Crues, Edwin Z.; Huynh, An; Nguyen, Hung T.; MacLean, John

    2006-01-01

    During the Orbiter Repair Maneuver (OM) operations planned for Return to Flight (RTF), the Shuttle Remote Manipulator System (SRMS) must grapple the International Space Station (ISS), undock the Orbiter, maneuver it through a long duration trajectory, and orient it to an EVA crewman poised at the end of the Space Station Remote Manipulator System (SSRMS) to facilitate the repair of the Thermal Protection System (TPS). Once repair has been completed and confirmed, then the SRMS proceeds back through the trajectory to dock the Orbiter to the Orbiter Docking System. In order to support analysis of the complex dynamic interactions of the integrated system formed by the Orbiter, ISS, SRMS, and SSMS during the ORM, simulation tools used for previous nominal mission support required substantial enhancements. These upgrades were necessary to provide analysts with the capabilities needed to study integrated system performance. Prevalent throughout this ORM operation is a dynamically varying topology. In other words, the ORM starts with the SRMS grappled to the mated Shuttle/ISS stack (closed loop topology), moves to an open loop chain topology consisting of the Shuttle, SRMS, and ISS, and then, at the repair configuration, extends the chain topology to one consisting of the Shuttle, SMS, ISS, and SSRMS/EVA crewman. The resulting long dynamic chain of vehicles and manipulators may exhibit significant motion between the Shuttle worksite and the EVA crewman due to the system flexibility throughout the topology (particularly within the SRMS/SSRMS joints and links). Since the attachment points of both manipulators span the flexible structure of the ISS, simulation analysis may also need to take that into consideration. Moreover, due to the lengthy time duration associated with the maneuver and repair, orbital effects become a factor and require the ISS vehicle control system to maintain active attitude control. Several facets of the ORM operation make the associated analytical efforts different from previous mission support, including: (1) the magnitude of the SRMS handled payload (Le., Orbiter class), (2) the orbital effects induced on the integrated system consisting of the large Shuttle and ISS masses connected by a light flexible SRMS, (3) long duration environmental consequences due to the lengthy operational times associated with the maneuver and repair of the TPS, (4) active attitude control (as opposed to free drift) interacting with the SRMS and SSRMS manipulators (also due to the length of the maneuver and repair), (5) relative dynamics between the EVA crewman and thc worksite influenced by the extended flexible topology. In order to meet these analysis challenges, an O Msi mulation architecture was developed leveraging upon numerous pre-existing simulation elements to analyze the various subsystems individually. For example, core manipulator subsystem simulations for both the SRMS and SSRMS were originally combined to provide the dual-arm dynamics topology simulation (in the absence of orbital dynamics and vehicle control). This capability was later merged with the simulation used to analyze SRMS loading with a heavy payload in the orbital environment with an active payload control system (in this case, the ISS Attitude Control System (ACS)), configured for the ORM. The resulting worksite dynamics simulation, based off of the modified ORM simulation, provided the extended topological chain of vehicles and manipulators, while taking into account the orbital effects of both the Shuttle and ISS (as well as its ACS). Verification and validation (V&V) of these integrated simulations became a challenge in itself. A systematic approach needed to be developed such that integration simulation results could be tested against previous constituent simulations upon which these simulations were built. General V&V categories included: (1) core orbital state propagation, (2), stand-alone SRMS, (3) stand-alone SSRMS, (4) stand-alone ISS ACS, (5)ntegrated Shuttle, SRMS, ISS (with active ACS) in the orbital environment, and (5) dual-arm SRMS/SSRMS dynamics topology. Integrated simulation V&V run suites were created and correlated to verification runs from subsystem simulations, in order to establish the validity of the results. This paper discusses the simulation design challenges encountered while developing simulation capabilities to mirror the ORM operations. The paper also describes the incremental build approach that was utilized, starting with the subsystem simulation elements and integration into increasing more complex simulations until the resulting ORM worksite dynamics simulation had been assembled. Furthermore, the paper presents an overall integrated simulation V&V methodology based upon a subsystem level testing, integrated comparisons, and phased checkout.

  11. Experimental research on the effectiveness and adaptability of speed reduction markings in downhill sections on urban roads: a driving simulation study.

    PubMed

    Ding, Han; Zhao, Xiaohua; Rong, Jian; Ma, Jianming

    2015-02-01

    The objective of this paper is to test the effectiveness and adaptability of speed reduction markings (SRMs) in downhill sections on urban roads with distinct roadway grades. Empirical data including vehicle speed and acceleration were collected in a driving simulator. Subjective questionnaires were conducted, and two indexes - the relative speed difference and standard deviation of acceleration - were developed to evaluate the effectiveness and adaptability of SRMs. Meanwhile, the effectiveness of driving simulator related to different road alignments and types of SRMs has been validated through a field test. Results of subjective questionnaires showed that the majority of subjects had no feelings of nervousness, but they were affected by SRMs while driving through downhill sections in all four scenarios (i.e., downhill sections with vertical grades of 3, 2, 1.5 and 1%). In terms of vehicle speed and acceleration, the results of the analysis of variance (ANOVA) and the contrast analysis (S-N-K method) indicated that SRMs were significantly effective when roadway grades of downgrade sections were 1.5, 2 and 3%, while transverse speed reduction markings (TSRMs) had significantly worse adaptability (P<0.05). Therefore, this research recommends that TSRMs could be placed in downhill sections with roadway grades of 1.5 or 2%; longitudinal speed reduction markings (LSRMs) could be placed in downhill sections with a roadway grade of 3%. Whether SRMs are placed in downhill sections with a roadway grade of 1% would depend on other factors such as financial issues and crash records, which are not considered in this paper. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Liquid chromatography with isotope-dilution mass spectrometry for determination of water-soluble vitamins in foods.

    PubMed

    Phillips, Melissa M

    2015-04-01

    Vitamins are essential for improving and maintaining human health, and the main source of vitamins is the diet. Measurement of the quantities of water-soluble vitamins in common food materials is important to understand the impact of vitamin intake on human health, and also to provide necessary information for regulators to determine adequate intakes. Liquid chromatography (LC) and mass spectrometry (MS) based methods for water-soluble vitamin analysis are abundant in the literature, but most focus on only fortified foods or dietary supplements or allow determination of only a single vitamin. In this work, a method based on LC/MS and LC/MS/MS has been developed to allow simultaneous quantitation of eight water-soluble vitamins, including multiple forms of vitamins B3 and B6, in a variety of fortified and unfortified food-matrix Standard Reference Materials (SRMs). Optimization of extraction of unbound vitamin forms and confirmation using data from external laboratories ensured accuracy in the assigned values, and addition of stable isotope labeled internal standards for each of the vitamins allowed for increased precision.

  13. 76 FR 51459 - Office of Commercial Space Transportation (AST); Notice of Availability of the Record of Decision...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-18

    ... impacts of up to five solid-propellant strap-on rocket motors (SRMs) on the Atlas V medium lift vehicle... Proposed Action in the 2000 SEIS, up to five solid- propellant strap-on rocket motors (SRMs) would be added...

  14. Study of solid rocket motors for a space shuttle booster. Appendix D: Recovery and reuse 156-inch diameter solid rocket motor booster

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The baseline for a space shuttle configuration utilizing two parallel-burn, 156-in.-diameter SRMs with three segments and techroll seal movable nozzles is presented. The concept and general economic benefits of SRM recovery are equally valid for the series-burn SRMs, provided that those SRMs are also designed for the same strength, stiffness, segmentation, and interchangeability as the present design, and that those SRMs are also recovered as individual units. Feasibility studies were initiated to investigate SRM recoverability. These studies were based upon recovery of the SRM boosters for the Titan 3C. Ground rules precluded SRM modification that required significant changes in motor qualification or schedule. Even with this restriction, the study determined that the recoverable booster concept was completely feasible, both technically and economically. Parachute recovery has been selected as the best method, principally because it can accomplish the task with a minimum development cost and time to achieve operational recovery status. This system affords the highest probability for achieving large cost reductions.

  15. NHPP-Based Software Reliability Models Using Equilibrium Distribution

    NASA Astrophysics Data System (ADS)

    Xiao, Xiao; Okamura, Hiroyuki; Dohi, Tadashi

    Non-homogeneous Poisson processes (NHPPs) have gained much popularity in actual software testing phases to estimate the software reliability, the number of remaining faults in software and the software release timing. In this paper, we propose a new modeling approach for the NHPP-based software reliability models (SRMs) to describe the stochastic behavior of software fault-detection processes. The fundamental idea is to apply the equilibrium distribution to the fault-detection time distribution in NHPP-based modeling. We also develop efficient parameter estimation procedures for the proposed NHPP-based SRMs. Through numerical experiments, it can be concluded that the proposed NHPP-based SRMs outperform the existing ones in many data sets from the perspective of goodness-of-fit and prediction performance.

  16. An assessment of 25-hydroxyvitamin D measurements in comparability studies conducted by the Vitamin D Metabolites Quality Assurance Program.

    PubMed

    Bedner, Mary; Lippa, Katrice A; Tai, Susan S-C

    2013-11-15

    The National Institute of Standards and Technology (NIST), in collaboration with the National Institutes of Health Office of Dietary Supplements, established the first accuracy-based program for improving the comparability of vitamin D metabolite measurements, the Vitamin D Metabolites Quality Assurance Program. The study samples were human serum or plasma Standard Reference Materials (SRMs) with 25-hydroxyvitamin D values that were determined at NIST. Participants evaluated the materials using immunoassay (IA), liquid chromatography (LC) with mass spectrometric detection, and LC with ultraviolet absorbance detection. NIST evaluated the results for concordance within the participant community as well as trueness relative to the NIST value. For the study materials that contain mostly 25-hydroxyvitamin D3 (25(OH)D3),the coefficient of variation (CV) for the participant results was consistently in the range from 7% to 19%, and the median values were biased high relative to the NIST values. However, for materials that contain significant concentrations of both 25-hydroxyvitamin D2 (25(OH)D2) and 25(OH)D3, the median IA results were biased lower than both the LC and the NIST values, and the CV was as high as 28%. The first interlaboratory comparison results for SRM 972a Vitamin D Metabolites in Human Serum are also reported. Relatively large within-lab and between-lab variability hinders conclusive assessments of bias and accuracy. © 2013.

  17. Reaction control system/remote manipulator system automation

    NASA Technical Reports Server (NTRS)

    Hiers, Harry K.

    1990-01-01

    The objectives of this project is to evaluate the capability of the Procedural Reasoning System (PRS) in a typical real-time space shuttle application and to assess its potential for use in the Space Station Freedom. PRS, developed by SRI International, is a result of research in automating the monitoring and control of spacecraft systems. The particular application selected for the present work is the automation of malfunction handling procedures for the Shuttle Remote Manipulator System (SRMS). The SRMS malfunction procedures will be encoded within the PRS framework, a crew interface appropriate to the RMS application will be developed, and the real-time data interface software developed. The resulting PRS will then be integrated with the high-fidelity On-orbit Simulation of the NASA Johnson Space Center's System Engineering Simulator, and tests under various SRMS fault scenarios will be conducted.

  18. Usefulness of the Ice-Cream Cone Pattern in Computed Tomography for Prediction of Angiomyolipoma in Patients With a Small Renal Mass

    PubMed Central

    Kim, Kwang Ho; Yun, Bu Hyeon; Hwang, In Sang; Hwang, Eu Chang; Kang, Taek Won; Kwon, Dong Deuk; Park, Kwangsung; Kim, Jin Woong

    2013-01-01

    Purpose A morphologic contour method for assessing an exophytic renal mass as benign versus malignant on the basis of the shape of the interface with the renal parenchyma was recently developed. We investigated the usefulness of this morphologic contour method for predicting angiomyolipoma (AML) in patients who underwent partial nephrectomy for small renal masses (SRMs). Materials and Methods From January 2004 to March 2013, among 197 patients who underwent partial nephrectomy for suspicious renal cell carcinoma (RCC), the medical records of 153 patients with tumors (AML or RCC) ≤3 cm in diameter were retrospectively reviewed. Patient characteristics including age, gender, type of surgery, size and location of tumor, pathologic results, and specific findings of the imaging study ("ice-cream cone" shape) were compared between the AML and RCC groups. Results AML was diagnosed in 18 patients and RCC was diagnosed in 135 patients. Gender (p=0.001), tumor size (p=0.032), and presence of the ice-cream cone shape (p=0.001) showed statistically significant differences between the AML group and the RCC group. In the multivariate logistic regression analysis, female gender (odds ratio [OR], 5.20; 95% confidence interval [CI], 1.45 to 18.57; p=0.011), tumor size (OR, 0.34; 95% CI, 0.12 to 0.92; p=0.034), and presence of the ice-cream cone shape (OR, 18.12; 95% CI, 4.97 to 66.06; p=0.001) were predictors of AML. Conclusions This study confirmed a high incidence of AML in females. Also, the ice-cream cone shape and small tumor size were significant predictors of AML in SRMs. These finding could be beneficial for counseling patients with SRMs. PMID:23956824

  19. Evaluation of radiochemical neutron activation analysis methods for determination of arsenic in biological materials.

    PubMed

    Paul, Rick L

    2011-01-01

    Radiochemical neutron activation analysis (RNAA) with retention on hydrated manganese dioxide (HMD) has played a key role in the certification of As in biological materials at NIST. Although this method provides very high and reproducible yields and detection limits at low microgram/kilogram levels, counting geometry uncertainties may arise from unequal distribution of As in the HMD, and arsenic detection limits may not be optimal due to significant retention of other elements. An alternate RNAA procedure with separation of arsenic by solvent extraction has been investigated. After digestion of samples in nitric and perchloric acids, As(III) is extracted from 2 M sulfuric acid solution into a solution of zinc diethyldithiocarbamate in chloroform. Counting of (76)As allows quantitation of arsenic. Addition of an (77)As tracer solution prior to dissolution allows correction for chemical yield and counting geometries, further improving reproducibility. The HMD and solvent extraction procedures for arsenic were compared through analysis of SRMs 1577c (bovine liver), 1547 (peach leaves), and 1575a (pine needles). Both methods gave As results in agreement with certified values with comparable reproducibility. However, the solvent extraction method yields a factor of 3 improvement in detection limits and is less time-consuming than the HMD method. The new method shows great promise for use in As certification in reference materials.

  20. Solid-propellant rocket motor ballistic performance variation analyses

    NASA Technical Reports Server (NTRS)

    Sforzini, R. H.; Foster, W. A., Jr.

    1975-01-01

    Results are presented of research aimed at improving the assessment of off-nominal internal ballistic performance including tailoff and thrust imbalance of two large solid-rocket motors (SRMs) firing in parallel. Previous analyses using the Monte Carlo technique were refined to permit evaluation of the effects of radial and circumferential propellant temperature gradients. Sample evaluations of the effect of the temperature gradients are presented. A separate theoretical investigation of the effect of strain rate on the burning rate of propellant indicates that the thermoelastic coupling may cause substantial variations in burning rate during highly transient operating conditions. The Monte Carlo approach was also modified to permit the effects on performance of variation in the characteristics between lots of propellants and other materials to be evaluated. This permits the variabilities for the total SRM population to be determined. A sample case shows, however, that the effect of these between-lot variations on thrust imbalances within pairs of SRMs is minor in compariosn to the effect of the within-lot variations. The revised Monte Carlo and design analysis computer programs along with instructions including format requirements for preparation of input data and illustrative examples are presented.

  1. An Assessment of 25-Hydroxyvitamin D Measurements in Comparability Studies Conducted by the Vitamin D Metabolites Quality Assurance Program

    PubMed Central

    Bedner, Mary; Lippa, Katrice A.; Tai, Susan S.-C.

    2013-01-01

    Background The National Institute of Standards and Technology (NIST), in collaboration with the National Institutes of Health Office of Dietary Supplements, established the first accuracy-based program for improving the comparability of vitamin D metabolite measurements, the Vitamin D Metabolites Quality Assurance Program. Methods Study samples were comprised of human serum or plasma Standard Reference Materials (SRMs) with 25-hydroxyvitamin D values that were determined at NIST. Participants evaluated the materials using immunoassay (IA), liquid chromatography (LC) with mass spectrometric detection, and LC with ultraviolet absorbance detection. NIST evaluated the results for concordance within the participant community as well as trueness relative to the NIST value. Results For the study materials that contain mostly 25-hydroxyvitamin D3 (25(OH)D3), the coefficient of variation (CV) for the participant results was consistently in the range from 7% to 19%, and the median values were biased high relative to the NIST values. However, for materials that contain significant concentrations of both 25-hydroxyvitamin D2 (25(OH)D2) and 25(OH)D3, the median IA results were biased lower than both the LC and the NIST values, and the CV was as high as 28%. The first interlaboratory comparison results for SRM 972a Vitamin D Metabolites in Human Serum are also reported. Conclusions Relatively large within-lab and between-lab variability hinders conclusive assessments of bias and accuracy. PMID:23978484

  2. Tribomaterial factors in space mechanism brake performance

    NASA Technical Reports Server (NTRS)

    Hawthorne, H. M.

    1990-01-01

    The asbestos/phenolic pads of Shuttle Remote Manipulator System (SRMS) brakes are unsuitable for use in long life space mechanisms because their friction decreases on extended sliding in high vacuum. Dehydration of the material and accumulation of wear debris in the conforming interface of this tribosystem induces the permanent friction changes. Other polymer and some ceramic based materials exhibit similar frictional torque behavior due to the development of minimal contact patches by the interfacial debris. In contrast, high friction occurs when other ceramics form many small contacts throughout fine debris beds. Generating this latter interfacial structure during run-in ensures that the in-vacuo friction remains stable thereafter. Such materials with low wear rates are potential candidates for friction elements in SSRMS and similar mechanisms.

  3. Responsiveness of the WOMAC osteoarthritis index as compared with the SF-36 in patients with osteoarthritis of the legs undergoing a comprehensive rehabilitation intervention

    PubMed Central

    Angst, F; Aeschlimann, A; Steiner, W; Stucki, G

    2001-01-01

    OBJECTIVE—To compare the responsiveness of the condition-specific Western Ontario and McMaster Universities osteoarthritis (OA) index (WOMAC) and the generic Short Form-36 (SF-36) in patients with OA of the legs undergoing a comprehensive inpatient rehabilitation intervention.
METHODS—A prospective follow up study of consecutively referred inpatients of a rehabilitation clinic was made. The patients included fulfilled the American College of Rheumatology criteria for knee or hip OA and underwent both passive and, particularly, active physical therapy for three to four weeks. Responsiveness assessment was performed using the standardised response mean (SRM), effect size, and Guyatt's responsiveness statistic between admission and discharge (end of rehabilitation) and then again between admission and three months later. For pain and function the SRMs were stratified by sex and OA joint. Effects were tested by the t test and SRMs of different scales were compared by the jack knife test.
RESULTS—At the three month follow up, complete data were obtained for 223 patients. In general, the three responsiveness statistics showed a similar order of responsiveness. For both instruments, the pain scales were more responsive than the function scales. The responsiveness of the pain scale of both instruments was comparable (SRM=0.723 for WOMAC and SRM=0.528 for SF-36 at the end of rehabilitation; SRM=0.377 for WOMAC and SRM=0.468 for SF-36 at the three month follow up). In the measurement of function, the WOMAC was significantly more responsive than the SF-36 (SRMs, end of rehabilitation: 0.628 v 0.249; three month follow up: 0.235 v −0.001). Responsiveness tended to be higher in women and in knee OA than in men and hip OA.
CONCLUSIONS—Both instruments, the WOMAC and the SF-36, capture improvement in pain in patients undergoing comprehensive inpatient rehabilitation intervention. Functional improvement can be detected better by the WOMAC than by the SF-36. All the other scales of both instruments were more weakly responsive.

 PMID:11502609

  4. Depth Distribution and Assembly of Sulfate-Reducing Microbial Communities in Marine Sediments of Aarhus Bay

    PubMed Central

    Jochum, Lara M.; Chen, Xihan; Lever, Mark A.; Loy, Alexander; Jørgensen, Bo Barker; Schramm, Andreas

    2017-01-01

    ABSTRACT Most sulfate-reducing microorganisms (SRMs) present in subsurface marine sediments belong to uncultured groups only distantly related to known SRMs, and it remains unclear how changing geochemical zones and sediment depth influence their community structure. We mapped the community composition and abundance of SRMs by amplicon sequencing and quantifying the dsrB gene, which encodes dissimilatory sulfite reductase subunit beta, in sediment samples covering different vertical geochemical zones ranging from the surface sediment to the deep sulfate-depleted subsurface at four locations in Aarhus Bay, Denmark. SRMs were present in all geochemical zones, including sulfate-depleted methanogenic sediment. The biggest shift in SRM community composition and abundance occurred across the transition from bioturbated surface sediments to nonbioturbated sediments below, where redox fluctuations and the input of fresh organic matter due to macrofaunal activity are absent. SRM abundance correlated with sulfate reduction rates determined for the same sediments. Sulfate availability showed a weaker correlation with SRM abundances and no significant correlation with the composition of the SRM community. The overall SRM species diversity decreased with depth, yet we identified a subset of highly abundant community members that persists across all vertical geochemical zones of all stations. We conclude that subsurface SRM communities assemble by the persistence of members of the surface community and that the transition from the bioturbated surface sediment to the unmixed sediment below is a main site of assembly of the subsurface SRM community. IMPORTANCE Sulfate-reducing microorganisms (SRMs) are key players in the marine carbon and sulfur cycles, especially in coastal sediments, yet little is understood about the environmental factors controlling their depth distribution. Our results suggest that macrofaunal activity is a key driver of SRM abundance and community structure in marine sediments and that a small subset of SRM species of high relative abundance in the subsurface SRM community persists from the sulfate-rich surface sediment to sulfate-depleted methanogenic subsurface sediment. More generally, we conclude that SRM communities inhabiting the subsurface seabed assemble by the selective survival of members of the surface community. PMID:28939599

  5. Laser-Excited Atomic Fluorescence and Ionization in a Graphite Furnace for the Determination of Metals and Nonmetals

    NASA Astrophysics Data System (ADS)

    Butcher, David James

    1990-01-01

    Here is reported novel instrumentation for atomic spectrometry that combined the use of a pulsed laser system as the light source and an electrothermal atomizer as the atom cell. The main goal of the research was to develop instrumentation that was more sensitive for elemental analysis than commercially available instruments and could be used to determine elements in real sample matrices. Laser excited atomic fluorescence spectrometry (LEAFS) in an electrothermal atomizer (ETA) was compared to ETA atomic absorption spectrometry (AAS) for the determination of thallium, manganese, and lead in food and agricultural standard reference materials (SRMs). Compared to ETA AAS, ETA LEAFS has a longer linear dynamic range (LDR) (5-7 orders of magnitude compared to 2-3 orders of magnitude) and higher sensitivity (10 ^{-16} to 10^{ -14} g as compared to 10^{ -13} to 10^{-11} g). Consequently, ETA LEAFS allows elemental analysis to be done over a wider range of concentrations with less dilution steps. Thallium was accurately determined in biological samples by ETA LEAFS at amounts five to one hundred times below the ETA AAS detection limit. ETA AAS and ETA LEAFS were compared for the determination of lead and manganese, and in general, the accuracies and precisions of ETA AAS were the same, with typical precisions between 3% and 6%. Fluorine was determined using laser excited molecular fluorescence spectrometry (LEMOFS) in an ETA. Molecular fluorescence from magnesium fluoride was collected, and the detection limit of 0.3 pg fluorine was two to six orders of magnitude more sensitive than other methods commonly used for the determination of fluorine. Significant interferences from ions were observed, but the sensitivity was high enough that fluorine could be determined in freeze dried urine SRMs by diluting the samples by a factor of one hundred to remove the interferences. Laser enhanced ionization (LEI) in an ETA was used for the determination of metals. For thallium, indium, and lithium, detection limits between 0.7 and 2 pg were obtained, with an LDR of 3.5 orders of magnitude. Sodium was shown to severely depress the indium LEI signal in an ETA.

  6. Development of a NIST standard reference material containing thirty volatile organic compounds at 5 nmol/mol in nitrogen.

    PubMed

    Rhoderick, George C; Yen, James H

    2006-05-01

    Primary gravimetric gas cylinder standards containing 30 volatile organic compounds (VOCs) in nitrogen were prepared using a procedure previously developed to prepare gas mixture cylinder standards of VOCs at the 5 nmol/mol level. This set of primary standards was intercompared to existing gas cylinder standards, containing as many as 19 of the 30 volatile organics present in these new primaries, using gas chromatography with a hydrogen flame ionization detector coupled with cryogenic preconcentration. The linear regression analysis showed excellent agreement among the standards for each compound. Similar mixtures containing many of these compounds in treated aluminum gas cylinders have been evaluated over time and have shown stability for as much as 10 years. The development of these 30-component primary standards led to the preparation and certification of a reissue of Standard Reference Material (SRM) 1804 at the nominal amount-of-substance fraction of 5 nmol/mol for each analyte. A lot of 20 cylinders containing the mixture was prepared at NIST following previously demonstrated protocols for preparation of the cylinders. Each cylinder was analyzed against one cylinder from the lot, designated as the "lot standard," for each of the 30 compounds. As a result of the uncertainty analysis, the data showed that rather than declaring the lot homogeneous with a much higher uncertainty, each cylinder could be individually certified. The expanded uncertainty limits ranged from 1.5 to 10% for 28 of the 30 analytes, with two of the analytes having uncertainties as high as 19% in those SRM cylinders certified. Due to stability issues and some high uncertainties for a few analytes in 2 of the samples, 18 of the 20 candidate SRM samples were certified. These volatile organic gas mixtures represent the most complex gas SRMs developed at NIST.

  7. Active surveillance for small renal masses diagnosed in elderly or comorbid patients: looking for the best treatment strategy.

    PubMed

    Brunocilla, E; Borghesi, M; Schiavina, R; Palmieri, F; Pernetti, R; Monti, C; Martorana, G

    2014-01-01

    Aim of this study is to provide our results after long-term active surveillance (AS) protocol for small renal masses (SRMs), and to report the outcomes of patients who remained in AS compared to those who underwent delayed surgical intervention. We retrospectively reviewed our database of 58 patients diagnosed with 60 contrast enhancing SRMs suspicious for renal cell carcinoma (RCC). All patients had clinical and radiological follow-up every 6 months. We evaluated the differences between patients who remained on AS and those who underwent surgical delayed intervention. The mean age was 75 years, the mean follow-up was 88.5 months. The median initial tumor size at presentation was 2.6cm, and the median estimated tumor volume was 8.7cm(3). The median linear growth rate of the cohort was 0.7cm/year, and the median volumetric growth rate was 8.8 cm(3)/year. Death for metastatic disease occurred in 2 patients (3.4%). No correlation was found between initial tumor size and size growth rate. The mean linear and volumetric growth rates of the group of patients who underwent surgery was higher than in those who remained on surveillance (1.9 vs. 0.4cm/year and 16.1 vs. 4.6 cm(3)/year, respectively; P<.001). Most of SRMs demonstrate to have an indolent course and low metastatic potential. Malignant disease could have faster linear and volumetric growth rates, thus suggesting the need for a delayed surgical intervention. In properly selected patients with low life-expectancy, AS could be a reasonable option in the management of SRMs. Copyright © 2013 AEU. Published by Elsevier Espana. All rights reserved.

  8. An Analysis of the Orbital Distribution of Solid Rocket Motor Slag

    NASA Technical Reports Server (NTRS)

    Horstman, Matthew F.; Mulrooney, Mark

    2007-01-01

    The contribution made by orbiting solid rocket motors (SRMs) to the orbital debris environment is both potentially significant and insufficiently studied. A combination of rocket motor design and the mechanisms of the combustion process can lead to the emission of sufficiently large and numerous by-products to warrant assessment of their contribution to the orbital debris environment. These particles are formed during SRM tail-off, or the termination of burn, by the rapid expansion, dissemination, and solidification of the molten Al2O3 slag pool accumulated during the main burn phase of SRMs utilizing immersion-type nozzles. Though the usage of SRMs is low compared to the usage of liquid fueled motors, the propensity of SRMs to generate particles in the 100 m and larger size regime has caused concern regarding their contributing to the debris environment. Particle sizes as large as 1 cm have been witnessed in ground tests conducted under vacuum conditions and comparable sizes have been estimated via ground-based telescopic and in-situ observations of sub-orbital SRM tail-off events. Using sub-orbital and post recovery observations, a simplistic number-size-velocity distribution of slag from on-orbit SRM firings was postulated. In this paper we have developed more elaborate distributions and emission scenarios and modeled the resultant orbital population and its time evolution by incorporating a historical database of SRM launches, propellant masses, and likely location and time of particulate deposition. From this analysis a more comprehensive understanding has been obtained of the role of SRM ejecta in the orbital debris environment, indicating that SRM slag is a significant component of the current and future population.

  9. Vibration mitigation for in-wheel switched reluctance motor driven electric vehicle with dynamic vibration absorbing structures

    NASA Astrophysics Data System (ADS)

    Qin, Yechen; He, Chenchen; Shao, Xinxin; Du, Haiping; Xiang, Changle; Dong, Mingming

    2018-04-01

    This paper presents a new approach for vibration mitigation based on a dynamic vibration absorbing structure (DVAS) for electric vehicles (EVs) that use in-wheel switched reluctance motors (SRMs). The proposed approach aims to alleviate the negative effects of vibration caused by the unbalanced electromagnetic force (UMEF) that arises from road excitations. The analytical model of SRMs is first formulated using Fourier series, and then a model of the coupled longitudinal-vertical dynamics is developed taking into consideration the external excitations consisting of the aerodynamic drag force and road unevenness. In addition, numerical simulations for a conventional SRM-suspension system and two novel DVASs are carried out for varying road levels specified by ISO standards and vehicle velocities. The results of the comparison reveal that a 35% improvement in ride comfort, 30% improvement of road handling, and 68% improvement in air gap between rotor and stator can be achieved by adopting the novel DVAS compared to the conventional SRM-suspension system. Finally, multi-body simulation (MBS) is performed using LMS Motion to validate the feasibility of the proposed DVAS. Analysis of the results shows that the proposed method can augment the effective application of SRMs in EVs.

  10. A Monte Carlo investigation of thrust imbalance of solid rocket motor pairs

    NASA Technical Reports Server (NTRS)

    Sforzini, R. H.; Foster, W. A., Jr.; Johnson, J. S., Jr.

    1974-01-01

    A technique is described for theoretical, statistical evaluation of the thrust imbalance of pairs of solid-propellant rocket motors (SRMs) firing in parallel. Sets of the significant variables, determined as a part of the research, are selected using a random sampling technique and the imbalance calculated for a large number of motor pairs. The performance model is upgraded to include the effects of statistical variations in the ovality and alignment of the motor case and mandrel. Effects of cross-correlations of variables are minimized by selecting for the most part completely independent input variables, over forty in number. The imbalance is evaluated in terms of six time - varying parameters as well as eleven single valued ones which themselves are subject to statistical analysis. A sample study of the thrust imbalance of 50 pairs of 146 in. dia. SRMs of the type to be used on the space shuttle is presented. The FORTRAN IV computer program of the analysis and complete instructions for its use are included. Performance computation time for one pair of SRMs is approximately 35 seconds on the IBM 370/155 using the FORTRAN H compiler.

  11. Retrospective Analysis of NIST Standard Reference Material 1450, Fibrous Glass Board, for Thermal Insulation Measurements.

    PubMed

    Zarr, Robert R; Heckert, N Alan; Leigh, Stefan D

    2014-01-01

    Thermal conductivity data acquired previously for the establishment of Standard Reference Material (SRM) 1450, Fibrous Glass Board, as well as subsequent renewals 1450a, 1450b, 1450c, and 1450d, are re-analyzed collectively and as individual data sets. Additional data sets for proto-1450 material lots are also included in the analysis. The data cover 36 years of activity by the National Institute of Standards and Technology (NIST) in developing and providing thermal insulation SRMs, specifically high-density molded fibrous-glass board, to the public. Collectively, the data sets cover two nominal thicknesses of 13 mm and 25 mm, bulk densities from 60 kg·m(-3) to 180 kg·m(-3), and mean temperatures from 100 K to 340 K. The analysis repetitively fits six models to the individual data sets. The most general form of the nested set of multilinear models used is given in the following equation: [Formula: see text]where λ(ρ,T) is the predicted thermal conductivity (W·m(-1)·K(-1)), ρ is the bulk density (kg·m(-3)), T is the mean temperature (K) and ai (for i = 1, 2, … 6) are the regression coefficients. The least squares fit results for each model across all data sets are analyzed using both graphical and analytic techniques. The prevailing generic model for the majority of data sets is the bilinear model in ρ and T. [Formula: see text] One data set supports the inclusion of a cubic temperature term and two data sets with low-temperature data support the inclusion of an exponential term in T to improve the model predictions. Physical interpretations of the model function terms are described. Recommendations for future renewals of SRM 1450 are provided. An Addendum provides historical background on the origin of this SRM and the influence of the SRM on external measurement programs.

  12. Seebeck Coefficient Metrology: Do Contemporary Protocols Measure Up?

    NASA Astrophysics Data System (ADS)

    Martin, Joshua; Wong-Ng, Winnie; Green, Martin L.

    2015-06-01

    Comparative measurements of the Seebeck coefficient are challenging due to the diversity of instrumentation and measurement protocols. With the implementation of standardized measurement protocols and the use of Standard Reference Materials (SRMs®), for example, the recently certified National Institute of Standards and Technology (NIST) SRM® 3451 ``Low Temperature Seebeck Coefficient Standard (10-390 K)'', researchers can reliably analyze and compare data, both intra- and inter-laboratory, thereby accelerating the development of more efficient thermoelectric materials and devices. We present a comparative overview of commonly adopted Seebeck coefficient measurement practices. First, we examine the influence of asynchronous temporal and spatial measurement of electric potential and temperature. Temporal asynchronicity introduces error in the absolute Seebeck coefficient of the order of ≈10%, whereas spatial asynchronicity introduces error of the order of a few percent. Second, we examine the influence of poor thermal contact between the measurement probes and the sample. This is especially critical at high temperature, wherein the prevalent mode of measuring surface temperature is facilitated by pressure contact. Each topic will include the comparison of data measured using different measurement techniques and using different probe arrangements. We demonstrate that the probe arrangement is the primary limit to high accuracy, wherein the Seebeck coefficients measured by the 2-probe arrangement and those measured by the 4-probe arrangement diverge with the increase in temperature, approaching ≈14% at 900 K. Using these analyses, we provide recommended measurement protocols to guide members of the thermoelectric materials community in performing more accurate measurements and in evaluating more comprehensive uncertainty limits.

  13. Integrated Simulation Design Challenges to Support TPS Repair Operations

    NASA Technical Reports Server (NTRS)

    Quiocho, Leslie J.; Crues, Edwin Z.; Huynh, An; Nguyen, Hung T.; MacLean, John

    2005-01-01

    During the Orbiter Repair Maneuver (ORM) operations planned for Return to Flight (RTF), the Shuttle Remote Manipulator System (SRMS) must grapple the International Space Station (ISS), undock the Orbiter, maneuver it through a long duration trajectory, and orient it to an EVA crewman poised at the end of the Space Station Remote Manipulator System (SSRMS) to facilitate the repair of the Thermal Protection System (TPS). Once repair has been completed and confirmed, then the SRMS proceeds back through the trajectory to dock the Orbiter to the Orbiter Docking System. In order to support analysis of the complex dynamic interactions of the integrated system formed by the Orbiter, ISS, SRMS, and SSRMS during the ORM, simulation tools used for previous 'nominal' mission support required substantial enhancements. These upgrades were necessary to provide analysts with the capabilities needed to study integrated system performance. This paper discusses the simulation design challenges encountered while developing simulation capabilities to mirror the ORM operations. The paper also describes the incremental build approach that was utilized, starting with the subsystem simulation elements and integration into increasing more complex simulations until the resulting ORM worksite dynamics simulation had been assembled. Furthermore, the paper presents an overall integrated simulation V&V methodology based upon a subsystem level testing, integrated comparisons, and phased checkout.

  14. Fault Diagnostics and Prognostics for Large Segmented SRMs

    NASA Technical Reports Server (NTRS)

    Luchinsky, Dmitry; Osipov, Viatcheslav V.; Smelyanskiy, Vadim N.; Timucin, Dogan A.; Uckun, Serdar; Hayashida, Ben; Watson, Michael; McMillin, Joshua; Shook, David; Johnson, Mont; hide

    2009-01-01

    We report progress in development of the fault diagnostic and prognostic (FD&P) system for large segmented solid rocket motors (SRMs). The model includes the following main components: (i) 1D dynamical model of internal ballistics of SRMs; (ii) surface regression model for the propellant taking into account erosive burning; (iii) model of the propellant geometry; (iv) model of the nozzle ablation; (v) model of a hole burning through in the SRM steel case. The model is verified by comparison of the spatially resolved time traces of the flow parameters obtained in simulations with the results of the simulations obtained using high-fidelity 2D FLUENT model (developed by the third party). To develop FD&P system of a case breach fault for a large segmented rocket we notice [1] that the stationary zero-dimensional approximation for the nozzle stagnation pressure is surprisingly accurate even when stagnation pressure varies significantly in time during burning tail-off. This was also found to be true for the case breach fault [2]. These results allow us to use the FD&P developed in our earlier research [3]-[6] by substituting head stagnation pressure with nozzle stagnation pressure. The axial corrections to the value of the side thrust due to the mass addition are taken into account by solving a system of ODEs in spatial dimension.

  15. Dichotomous versus semi-quantitative scoring of ultrasound joint inflammation in rheumatoid arthritis using novel individualized joint selection methods.

    PubMed

    Tan, York Kiat; Allen, John C; Lye, Weng Kit; Conaghan, Philip G; Chew, Li-Ching; Thumboo, Julian

    2017-05-01

    The aim of the study is to compare the responsiveness of two joint inflammation scoring systems (dichotomous scoring (DS) versus semi-quantitative scoring (SQS)) using novel individualized ultrasound joint selection methods and existing ultrasound joint selection methods. Responsiveness measured by the standardized response means (SRMs) using the DS and the SQS system (for both the novel and existing ultrasound joint selection methods) was derived using the baseline and the 3-month total inflammatory scores from 20 rheumatoid arthritis patients. The relative SRM gain ratios (SRM-Gains) for both scoring system (DS and SQS) comparing the novel to the existing methods were computed. Both scoring systems (DS and SQS) demonstrated substantial SRM-Gains (ranged from 3.31 to 5.67 for the DS system and ranged from 1.82 to 3.26 for the SQS system). The SRMs using the novel methods ranged from 0.94 to 1.36 for the DS system and ranged from 0.89 to 1.11 for the SQS system. The SRMs using the existing methods ranged from 0.24 to 0.32 for the DS system and ranged from 0.34 to 0.49 for the SQS system. The DS system appears to achieve high responsiveness comparable to SQS for the novel individualized ultrasound joint selection methods.

  16. On the certification of cadmium at trace and ultratrace levels in standard reference materials using ID ICP-MS.

    PubMed

    Murphy, K E; Long, S E; Vocke, R D

    2007-04-01

    Analytical methods used for the isotope dilution inductively coupled plasma mass spectrometric (ID-ICP-MS) measurement of Cd at microg kg(-1) and sub-microg kg(-1) levels are described and applied to the certification of new dietary supplement, blood, and serum Standard Reference Materials (SRMs). The materials are: SRM 3240 Ephedra sinica Stapf Aerial Parts, SRM 3241 Ephedra sinica Stapf Native Extract, SRM 3243 Ephedra-Containing Solid Oral Dosage Form, SRM 3244 Ephedra-Containing Protein Powder, SRM 966 Toxic Metals in Bovine Blood, Level 1 (L1) and Level 2 (L2), and SRM 1598a Animal Serum. The concentration of Cd in the materials ranges from 120 microg kg(-1) down to 0.03 microg kg(-1). At these levels, the factors that most influence the accuracy of the ICP-MS data are the procedure blank and spectral and nonspectral interferences. Nonspectral interference, caused by the high concentration of dissolved solids in the matrices investigated, resulted in signal suppression. Matrix separation was used to enhance signal intensity and to reduce spectral interference for the accurate determination of Cd in SRM 1598a and SRM 3244. Chromatographic separation procedures using Chelex for SRM 1598a and anion exchange for SRM 3244 were optimized to achieve the desired separation characteristics without substantially increasing the procedure blank. Sensitivity for the determination of Cd in serum was additionally enhanced through the use of desolvation nebulization. We determined that separations were not required for the accurate ICP-MS determination of Cd in SRM 3240, SRM 3241, SRM 3243, and SRM 966 L2 under optimized analysis conditions. These samples were diluted to a minimum volume and introduced to the ICP-MS via low flow (40-100 microL/min) microconcentric nebulizers. SRM 966 L1 was also analyzed directly, but results were highly variable. The ID-ICP-MS sample preparation and ratio measurement protocols described here resulted in total expanded uncertainties of less than 1% for the determination of 90.85 microg kg(-1) Cd in SRM 3240, and less than 10% total expanded uncertainty for the determination of 0.0468 microg kg(-1) Cd in SRM 1598a.

  17. Laparoscopic reversal of mini-gastric bypass to original anatomy for severe postoperative malnutrition.

    PubMed

    Genser, Laurent; Soprani, Antoine; Tabbara, Malek; Siksik, Jean-Michel; Cady, Jean; Carandina, Sergio

    2017-12-01

    Malnutrition after mini-gastric bypass (MGB) is a rare and dreaded complication with few data available regarding its surgical management. We aim to report the feasibility, safety, and results of laparoscopic reversal of MGB to normal anatomy (RMGB) in case of severe and refractory malnutrition syndrome after intensive nutritional support (SRMS). A 10-year retrospective chart review was performed on patients who underwent RMGB (video included) for SRMS following MGB. Twenty-six of 2934 patients underwent a RMGB at a mean delay of 20.9 ± 13.4 months post-MGB. At presentation, mean body mass index (BMI), excess weight loss (%EWL), and albumin serum level were 22 ± 4.4 kg/m 2 , 103.6 ± 22.5%, and 25.5 ± 3.6 gr/L, respectively. Seventeen (63.5%) patients had at least one severe malnutrition related complication including severe edema in 13 (50%), venous ulcers in 2 (7.7%), infectious complications in 7 (27%), deep venous thrombosis in 5 (19.2%), and motor deficit in 5 (19.2%) patients. At surgical exploration, 8 of 12 (66.5%) patients had a biliary limb longer than 200 cm and 9 (34.6%) had bile reflux symptoms. Overall morbidity was 30.8% but lower when resecting the entire previous gastrojejunostomy with creation of a new jejunojejunostomy (8.3 vs 50%, p = 0.03). After a mean follow-up of 8 ± 9.7 months, all patients experienced a complete clinical and biological regression of the SRMS after the RMGB despite a mean 13.9 kg weight regain in 16 (61.5%) patients. Post-MGB SRMS and its related comorbidities are rare but dreaded conditions. Although burdened by a significant postoperative morbidity and weight regain, RMGB remains an effective option to consider, when intensive nutritional support fails.

  18. Tendon-Actuated Lightweight In-Space MANipulator (TALISMAN)

    NASA Technical Reports Server (NTRS)

    Dorsey, John T.; Doggett, William R.; Komendera, Erik E.

    2015-01-01

    The robotic architecture of State-of-the-Art (SOA) space manipulators, represented by the Shuttle Remote Manipulator System (SRMS), inherently limits their capabilities to extend reach, reduce mass, apply force and package efficiently. TALISMAN uses a new and innovative robotic architecture that incorporates a combination of lightweight truss links, a novel hinge joint, tendon-articulation and passive tension stiffening to achieve revolutionary performance. A TALISMAN with performance similar to the SRMS has 1/10th of its mass and packages in 1/7th of its volume. The TALISMAN architecture allows its reach to be scaled over a large range; from 10 to over 300 meters. In addition, the dexterity (number of degrees-of-freedom) can be easily adjusted without significantly impacting manipulator mass because the joints are very lightweight.

  19. Retrospective Analysis of NIST Standard Reference Material 1450, Fibrous Glass Board, for Thermal Insulation Measurements

    PubMed Central

    Zarr, Robert R; Heckert, N Alan; Leigh, Stefan D

    2014-01-01

    Thermal conductivity data acquired previously for the establishment of Standard Reference Material (SRM) 1450, Fibrous Glass Board, as well as subsequent renewals 1450a, 1450b, 1450c, and 1450d, are re-analyzed collectively and as individual data sets. Additional data sets for proto-1450 material lots are also included in the analysis. The data cover 36 years of activity by the National Institute of Standards and Technology (NIST) in developing and providing thermal insulation SRMs, specifically high-density molded fibrous-glass board, to the public. Collectively, the data sets cover two nominal thicknesses of 13 mm and 25 mm, bulk densities from 60 kg·m−3 to 180 kg·m−3, and mean temperatures from 100 K to 340 K. The analysis repetitively fits six models to the individual data sets. The most general form of the nested set of multilinear models used is given in the following equation: λ(ρ,T)=a0+a1ρ+a2T+a3T3+a4e−(T−a5a6)2where λ(ρ,T) is the predicted thermal conductivity (W·m−1·K−1), ρ is the bulk density (kg·m−3), T is the mean temperature (K) and ai (for i = 1, 2, … 6) are the regression coefficients. The least squares fit results for each model across all data sets are analyzed using both graphical and analytic techniques. The prevailing generic model for the majority of data sets is the bilinear model in ρ and T. λ(ρ,T)=a0+a1ρ+a2T One data set supports the inclusion of a cubic temperature term and two data sets with low-temperature data support the inclusion of an exponential term in T to improve the model predictions. Physical interpretations of the model function terms are described. Recommendations for future renewals of SRM 1450 are provided. An Addendum provides historical background on the origin of this SRM and the influence of the SRM on external measurement programs. PMID:26601034

  20. Reducing the Liquid Helium Consumption of Superconducting Rock Magnetometers (SRMs) used in Paleomagnetic and Rock Magnetic studies: Gallium Lubrication of Gifford-McMahon Cryocoolers Leads to a Dramatic Increase in Cool-down Efficiency, and a Drop in Liquid Helium Consumption

    NASA Astrophysics Data System (ADS)

    Kirschvink, J. L.

    2015-12-01

    Two-stage Gifford-McMahon helium-gas cryocoolers have been used for the past 40+ years in a wide variety of cryogenic applications, including reducing the liquid helium consumption of SRMs. However, the cooling efficiency depends greatly on the friction of the displacement pistons, which need to be replaced every few years. This and the rising cost of liquid helium are major headaches in the operation of modern paleomagnetic laboratories. Although the development of efficient pulse-tube cryocoolers has eliminated the need for liquid helium in new superconducting magnetometers, there are still nearly 100 older SRMs around the globe that use liquid helium. In a failed attempt to replace the Gifford-McMahon unit on one of Caltech's SRMs with a pulse-tube, we irreversibly contaminated the cylindrical surfaces of the stainless-steel heat exchanger with a thin film of gallium, a non-toxic metal that has a melting temperature of ~ 30˚C. Liquid gallium will diffuse into other metals, altering their surface properties. We noticed that the next cryocooler-assisted cool down of the SRM went nearly twice as fast as in previous cycles, and the helium boiloff rate for the past 2 years has stabilized at less than half of its average over the past 30 years. It seems that the thin layer of gallium may be reducing the sliding friction of the Gifford-McMahon cryocoolers. We recently tested this on a second SRM, with similar results. We found that the inner cryocooler surface reached its equilibrium temperature in about 1/3 of the time that it took in previous cool-down cycles. WSGI also confirmed that this cool-down was unusually efficient compared to other instruments they have built. Subsequent records of the helium gas boiloff show that this system is also running at about half of its former loss rate. Based on these two results, we tentatively recommend this simple procedure any time cold-head swaps are performed on these cryocoolers.

  1. Recognizing and overcoming analytical error in the use of ICP-MS for the determination of cadmium in breakfast cereal and dietary supplements.

    PubMed

    Murphy, Karen E; Vetter, Thomas W

    2013-05-01

    The potential effect of spectral interference on the accurate measurement of the cadmium (Cd) mass fraction in fortified breakfast cereal and a variety of dietary supplement materials using inductively coupled plasma quadrupole mass spectrometry was studied. The materials were two new standard reference materials (SRMs)--SRM 3233 Fortified Breakfast Cereal and SRM 3532 Calcium Dietary Supplement--as well as several existing materials--SRM 3258 Bitter Orange Fruit, SRM 3259 Bitter Orange Extract, SRM 3260 Bitter Orange-containing Solid Oral Dosage Form, and SRM 3280 Multivitamin/Multielement Tablets. Samples were prepared for analysis using the method of isotope dilution and measured using various operating and sample introduction configurations including standard mode, collision cell with kinetic energy discrimination mode, and standard mode with sample introduction via a desolvating nebulizer system. Three isotope pairs, (112)Cd/(111)Cd, (113)Cd/(111)Cd, and (114)Cd/(111)Cd, were measured. Cadmium mass fraction results for the unseparated samples of each material, measured using the three instrument configurations and isotope pairs, were compared to the results obtained after the matrix was removed via chemical separation using anion exchange chromatography. In four of the six materials studied, measurements using the standard mode with sample introduction via the desolvating nebulizer gave results for the unseparated samples quantified with the (112)Cd/(111)Cd isotope pair that showed a positive bias relative to the matrix-separated samples, which indicated a persistent inference at m/z112 with this configuration. Use of the standard mode, without the desolvating nebulizer, also gave results that showed a positive bias for the unseparated samples quantified with the (112)Cd/(111)Cd isotope pair in three of the materials studied. Collision cell/kinetic energy discrimination mode, however, was very effective for reducing spectral interference for Cd in all of the materials and isotope pairs studied, except in the multivitamin/multielement matrix (SRM 3280) where the large corrections for known isobaric interferences or unidentified interferences compromised the accuracy. For SRM 3280, matrix separation provided the best method to achieve accurate measurement of Cd.

  2. 9 CFR 95.1 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... the trimmings, which may include, but are not limited to, brains, thymus, pancreas, liver, heart... undetermined risk for BSE are considered SRMs if they are derived from bovines over 12 months of age: Brain...

  3. Space Shuttle Project

    NASA Image and Video Library

    1978-01-18

    Pictured is an early testing of the Solid Rocket Motor (SRM) at the Thiokol facility in Utah. The SRMs later became known as Solid Rocket Boosters (SRBs) as they were more frequently used on the Space Shuttles.

  4. Synthesis of the SRM Fragmentation Activities Performed within VEGA Program

    NASA Astrophysics Data System (ADS)

    Jarry, A.; Meyer-Lasalle, F.; Le Falc'her, D.

    2013-09-01

    In the frame of VEGA program and especially the first flight on February 13, 2013, safety was a major concern. The default of the launcher and its impact on the close range were amongst the development phase topics because of the propellant masses at stake and the surrounding inhabited environment. A task group composed of members from ESA, CNES and industrial partners involved was formed for this matter.All SRMs are equipped with destruction chains. While P80 (first stage) is functioning, the Zefiri remain unpressurized. A scenario was set stating that the activation of Zefiri cutting chord creates an ignited gap inside the propellant. This ought to propagate till the inner bore, driving the explosion of the motor.This scenario was studied through small scale tests and numerical simulation, providing confidence on the feasibility of the destruction of the SRMs as well as inputs in terms of safety delays.

  5. A Search for Viable Venus and Jupiter Sample Return Mission Trajectories for the Next Decade

    NASA Technical Reports Server (NTRS)

    Leong, Jason N.; Papadopoulos, Periklis

    2005-01-01

    Planetary exploration using unmanned spacecraft capable of returning geologic or atmospheric samples have been discussed as a means of gathering scientific data for several years. Both NASA and ESA performed initial studies for Sample Return Missions (SRMs) in the late 1990 s, but most suggested a launch before the year 2010. The GENESIS and STARDUST spacecraft are the only current examples of the SRM concept with the Mars SRM expected around 2015. A feasibility study looking at SRM trajectories to Venus and Jupiter, for a spacecraft departing the Earth between the years 2011 through 2020 was conducted for a university project. The objective of the study was to evaluate SRMs to planets other than Mars, which has already gained significant attention in the scientific community. This paper is a synopsis of the study s mission trajectory concept and the conclusions to the viability of such a mission with today s technology.

  6. Cost-utility analysis of radical nephrectomy versus partial nephrectomy in the management of small renal masses: Adjusting for the burden of ensuing chronic kidney disease

    PubMed Central

    Klinghoffer, Zachary; Tarride, Jean-Eric; Novara, Giacomo; Ficarra, Vincenzo; Kapoor, Anil; Shayegan, Bobby; Braga, Luis H.

    2013-01-01

    Objectives: We compare the cost-utility of laparoscopic radical nephrectomy (LRN), laparoscopic partial nephrectomy (LPN) and open partial nephrectomy (OPN) in the management of small renal masses (SRMs) when the impact of ensuing chronic kidney disease (CKD) disease is considered. Methods: We designed a Markov decision analysis model with a 10-year time horizon. Estimates of costs, utilities, complication rates and probabilities of developing CKD were derived from the literature. The base case patient was assumed to be a 65-year-old patient with a <4-cm unilateral renal mass, a normal contralateral kidney and a normal preoperative serum creatinine. Univariate and probabilistic sensitivity analyses were conducted to address the uncertainty associated with the study parameters. Results: OPN was the least costly strategy at $25 941 USD and generated 7.161 quality-adjusted life years (QALYs) over 10 years. LPN yielded 0.098 additional QALYs at an additional cost of $888 for an incremental cost-effectiveness ratio of $9057 per QALY, well below a commonly cited willingness-to-pay threshold of $50 000 per QALY. LRN was more costly and yielded fewer QALYs than OPN and LPN. Sensitivity analyses demonstrated our model to be robust to changes to key parameters. Age had no effect on preferred strategy. Conclusions: Partial nephrectomy (PN) is the preferred treatment strategy for SRMs. In centres where LPN is not available, OPN remains considerably more cost-effective than LRN. Furthermore, our study demonstrates that there is no age at which PN is not preferred to LRN. Our study provides additional evidence to advocate PN for the management of all amenable SRMs. PMID:23671525

  7. An analysis of the orbital distribution of solid rocket motor slag

    NASA Astrophysics Data System (ADS)

    Horstman, Matthew F.; Mulrooney, Mark

    2009-01-01

    The contribution by solid rocket motors (SRMs) to the orbital debris environment is potentially significant and insufficiently studied. Design and combustion processes can lead to the emission of enough by-products to warrant assessment of their contribution to orbital debris. These particles are formed during SRM tail-off, or burn termination, by the rapid solidification of molten Al2O3 slag accumulated during the burn. The propensity of SRMs to generate particles larger than 100μm raises concerns regarding the debris environment. Sizes as large as 1 cm have been witnessed in ground tests, and comparable sizes have been estimated via observations of sub-orbital tail-off events. Utilizing previous research we have developed more sophisticated size distributions and modeled the time evolution of resultant orbital populations using a historical database of SRM launches, propellant, and likely location and time of tail-off. This analysis indicates that SRM ejecta is a significant component of the debris environment.

  8. Space Launch System Base Heating Test: Sub-Scale Rocket Engine/Motor Design, Development and Performance Analysis

    NASA Technical Reports Server (NTRS)

    Mehta, Manish; Seaford, Mark; Kovarik, Brian; Dufrene, Aaron; Solly, Nathan; Kirchner, Robert; Engel, Carl D.

    2014-01-01

    The Space Launch System (SLS) base heating test is broken down into two test programs: (1) Pathfinder and (2) Main Test. The Pathfinder Test Program focuses on the design, development, hot-fire test and performance analyses of the 2% sub-scale SLS core-stage and booster element propulsion systems. The core-stage propulsion system is composed of four gaseous oxygen/hydrogen RS-25D model engines and the booster element is composed of two aluminum-based model solid rocket motors (SRMs). The first section of the paper discusses the motivation and test facility specifications for the test program. The second section briefly investigates the internal flow path of the design. The third section briefly shows the performance of the model RS-25D engines and SRMs for the conducted short duration hot-fire tests. Good agreement is observed based on design prediction analysis and test data. This program is a challenging research and development effort that has not been attempted in 40+ years for a NASA vehicle.

  9. Prediction of Radial Vibration in Switched Reluctance Machines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, CJ; Fahimi, B

    2013-12-01

    Origins of vibration in switched reluctance machines (SRMs) are investigated. Accordingly, an input-output model based on the mechanical impulse response of the SRMis developed. The proposed model is derived using an experimental approach. Using the proposed approach, vibration of the stator frame is captured and experimentally verified.

  10. Urban Educators' Perceptions of Culturally Relevant Pedagogy and School Reform Mandates

    ERIC Educational Resources Information Center

    Esposito, Jennifer; Davis, Corrie L.; Swain, Ayanna N.

    2012-01-01

    In this article, we examine urban teachers' perceptions of school reform models (SRMs) and culturally relevant pedagogy (CRP). In particular, we examined how urban educators altered mandated reform models in the best interests of their culturally and linguistically diverse students. We discuss data from a phenomenological study, which included…

  11. 76 FR 63172 - Airworthiness Directives; The Boeing Company Model 767 Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-12

    ... repetitive detailed and high frequency eddy current (HFEC) inspections of the station (STA) 1809.5 bulkhead... detailed and high frequency eddy current (HFEC) inspections for cracking as specified in Parts 1, 2, 3, and... rule to provide the applicable, current SRMs; we have re-identified subsequent tables accordingly. We...

  12. Effects of solid-propellant temperature gradients on the internal ballistics of the Space Shuttle

    NASA Technical Reports Server (NTRS)

    Sforzini, R. H.; Foster, W. A., Jr.; Shackelford, B. W., Jr.

    1978-01-01

    The internal ballistic effects of combined radial and circumferential grain temperature gradients are evaluated theoretically for the Space Shuttle solid rocket motors (SRMs). A simplified approach is devised for representing with closed-form mathematical expressions the temperature distribution resulting from the anticipated thermal history prior to launch. The internal ballistic effects of the gradients are established by use of a mathematical model which permits the propellant burning rate to vary circumferentially. Comparative results are presented for uniform and axisymmetric temperature distributions and the anticipated gradients based on an earlier two-dimensional analysis of the center SRM segment. The thrust imbalance potential of the booster stage is also assessed based on the difference in the thermal loading of the individual SRMs of the motor pair which may be encountered in both summer and winter environments at the launch site. Results indicate that grain temperature gradients could cause the thrust imbalance to be approximately 10% higher in the Space Shuttle than the imbalance caused by SRM manufacturing and propellant physical property variability alone.

  13. Monte Carlo investigation of thrust imbalance of solid rocket motor pairs

    NASA Technical Reports Server (NTRS)

    Sforzini, R. H.; Foster, W. A., Jr.

    1976-01-01

    The Monte Carlo method of statistical analysis is used to investigate the theoretical thrust imbalance of pairs of solid rocket motors (SRMs) firing in parallel. Sets of the significant variables are selected using a random sampling technique and the imbalance calculated for a large number of motor pairs using a simplified, but comprehensive, model of the internal ballistics. The treatment of burning surface geometry allows for the variations in the ovality and alignment of the motor case and mandrel as well as those arising from differences in the basic size dimensions and propellant properties. The analysis is used to predict the thrust-time characteristics of 130 randomly selected pairs of Titan IIIC SRMs. A statistical comparison of the results with test data for 20 pairs shows the theory underpredicts the standard deviation in maximum thrust imbalance by 20% with variability in burning times matched within 2%. The range in thrust imbalance of Space Shuttle type SRM pairs is also estimated using applicable tolerances and variabilities and a correction factor based on the Titan IIIC analysis.

  14. Simultaneous determination of macronutrients, micronutrients and trace elements in mineral fertilizers by inductively coupled plasma optical emission spectrometry

    NASA Astrophysics Data System (ADS)

    de Oliveira Souza, Sidnei; da Costa, Silvânio Silvério Lopes; Santos, Dayane Melo; dos Santos Pinto, Jéssica; Garcia, Carlos Alexandre Borges; Alves, José do Patrocínio Hora; Araujo, Rennan Geovanny Oliveira

    2014-06-01

    An analytical method for simultaneous determination of macronutrients (Ca, Mg, Na and P), micronutrients (Cu, Fe, Mn and Zn) and trace elements (Al, As, Cd, Pb and V) in mineral fertilizers was optimized. Two-level full factorial design was applied to evaluate the optimal proportions of reagents used in the sample digestion on hot plate. A Doehlert design for two variables was used to evaluate the operating conditions of the inductively coupled plasma optical emission spectrometer in order to accomplish the simultaneous determination of the analyte concentrations. The limits of quantification (LOQs) ranged from 2.0 mg kg- 1 for Mn to 77.3 mg kg- 1 for P. The accuracy and precision of the proposed method were evaluated by analysis of standard reference materials (SRMs) of Western phosphate rock (NIST 694), Florida phosphate rock (NIST 120C) and Trace elements in multi-nutrient fertilizer (NIST 695), considered to be adequate for simultaneous determination. Twenty-one samples of mineral fertilizers collected in Sergipe State, Brazil, were analyzed. For all samples, the As, Ca, Cd and Pb concentrations were below the LOQ values of the analytical method. For As, Cd and Pb the obtained LOQ values were below the maximum limit allowed by the Brazilian Ministry of Agriculture, Livestock and Food Supply (Ministério da Agricultura, Pecuária e Abastecimento - MAPA). The optimized method presented good accuracy and was effectively applied to quantitative simultaneous determination of the analytes in mineral fertilizers by inductively coupled plasma optical emission spectrometry (ICP OES).

  15. Procedures for determination of detection limits: application to high-performance liquid chromatography analysis of fat-soluble vitamins in human serum.

    PubMed

    Browne, Richard W; Whitcomb, Brian W

    2010-07-01

    Problems in the analysis of laboratory data commonly arise in epidemiologic studies in which biomarkers subject to lower detection thresholds are used. Various thresholds exist including limit of detection (LOD), limit of quantification (LOQ), and limit of blank (LOB). Choosing appropriate strategies for dealing with data affected by such limits relies on proper understanding of the nature of the detection limit and its determination. In this paper, we demonstrate experimental and statistical procedures generally used for estimating different detection limits according to standard procedures in the context of analysis of fat-soluble vitamins and micronutrients in human serum. Fat-soluble vitamins and micronutrients were analyzed by high-performance liquid chromatography with diode array detection. A simulated serum matrix blank was repeatedly analyzed for determination of LOB parametrically by using the observed blank distribution as well as nonparametrically by using ranks. The LOD was determined by combining information regarding the LOB with data from repeated analysis of standard reference materials (SRMs), diluted to low levels; from LOB to 2-3 times LOB. The LOQ was determined experimentally by plotting the observed relative standard deviation (RSD) of SRM replicates compared with the concentration, where the LOQ is the concentration at an RSD of 20%. Experimental approaches and example statistical procedures are given for determination of LOB, LOD, and LOQ. These quantities are reported for each measured analyte. For many analyses, there is considerable information available below the LOQ. Epidemiologic studies must understand the nature of these detection limits and how they have been estimated for appropriate treatment of affected data.

  16. Inorganic trace analysis by mass spectrometry

    NASA Astrophysics Data System (ADS)

    Becker, Johanna Sabine; Dietze, Hans-Joachim

    1998-10-01

    Mass spectrometric methods for the trace analysis of inorganic materials with their ability to provide a very sensitive multielemental analysis have been established for the determination of trace and ultratrace elements in high-purity materials (metals, semiconductors and insulators), in different technical samples (e.g. alloys, pure chemicals, ceramics, thin films, ion-implanted semiconductors), in environmental samples (waters, soils, biological and medical materials) and geological samples. Whereas such techniques as spark source mass spectrometry (SSMS), laser ionization mass spectrometry (LIMS), laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), glow discharge mass spectrometry (GDMS), secondary ion mass spectrometry (SIMS) and inductively coupled plasma mass spectrometry (ICP-MS) have multielemental capability, other methods such as thermal ionization mass spectrometry (TIMS), accelerator mass spectrometry (AMS) and resonance ionization mass spectrometry (RIMS) have been used for sensitive mono- or oligoelemental ultratrace analysis (and precise determination of isotopic ratios) in solid samples. The limits of detection for chemical elements using these mass spectrometric techniques are in the low ng g -1 concentration range. The quantification of the analytical results of mass spectrometric methods is sometimes difficult due to a lack of matrix-fitted multielement standard reference materials (SRMs) for many solid samples. Therefore, owing to the simple quantification procedure of the aqueous solution, inductively coupled plasma mass spectrometry (ICP-MS) is being increasingly used for the characterization of solid samples after sample dissolution. ICP-MS is often combined with special sample introduction equipment (e.g. flow injection, hydride generation, high performance liquid chromatography (HPLC) or electrothermal vaporization) or an off-line matrix separation and enrichment of trace impurities (especially for characterization of high-purity materials and environmental samples) is used in order to improve the detection limits of trace elements. Furthermore, the determination of chemical elements in the trace and ultratrace concentration range is often difficult and can be disturbed through mass interferences of analyte ions by molecular ions at the same nominal mass. By applying double-focusing sector field mass spectrometry at the required mass resolution—by the mass spectrometric separation of molecular ions from the analyte ions—it is often possible to overcome these interference problems. Commercial instrumental equipment, the capability (detection limits, accuracy, precision) and the analytical application fields of mass spectrometric methods for the determination of trace and ultratrace elements and for surface analysis are discussed.

  17. STS-111 Expedition Five Crew Training Clip

    NASA Technical Reports Server (NTRS)

    2002-01-01

    The STS-111 Expedition Five Crew begins with training on payload operations. Flight Engineer Peggy Whitson and Mission Specialist Sandy Magnus are shown in Shuttle Remote Manipulator System (SRMS) procedures. Flight Engineer Sergei Treschev gets suited for Neutral Neutral Buoyancy Lab (NBL) training. Virtual Reality lab training is shown with Peggy Whitson. Habitation Equipment and procedures are also presented.

  18. Analysis of pressure blips in aft-finocyl solid rocket motor

    NASA Astrophysics Data System (ADS)

    Di Giacinto, M.; Favini, B.; Cavallini, E.

    2016-07-01

    Ballistic anomalies have frequently occurred during the firing of several solid rocket motors (SRMs) (Inertial Upper Stage, Space Shuttle Redesigned SRM (RSRM) and Titan IV SRM Upgrade (SRMU)), producing even relevant and unexpected variations of the SRM pressure trace from its nominal profile. This paper has the purpose to provide a numerical analysis of the following possible causes of ballistic anomalies in SRMs: an inert object discharge, a slag ejection, and an unexpected increase in the propellant burning rate or in the combustion surface. The SRM configuration under investigation is an aft-finocyl SRM with a first-stage/small booster design. The numerical simulations are performed with a quasi-one-dimensional (Q1D) unsteady model of the SRM internal ballistics, properly tailored to model each possible cause of the ballistic anomalies. The results have shown that a classification based on the head-end pressure (HEP) signature, relating each other the HEP shape and the ballistic anomaly cause, can be made. For each cause of ballistic anomalies, a deepened discussion of the parameters driving the HEP signatures is provided, as well as qualitative and quantitative assessments of the resultant pressure signals.

  19. Solid propellant rocket motor internal ballistics performance variation analysis, phase 3

    NASA Technical Reports Server (NTRS)

    Sforzini, R. H.; Foster, W. A., Jr.; Murph, J. E.; Adams, G. W., Jr.

    1977-01-01

    Results of research aimed at improving the predictability of off nominal internal ballistics performance of solid propellant rocket motors (SRMs) including thrust imbalance between two SRMs firing in parallel are reported. The potential effects of nozzle throat erosion on internal ballistic performance were studied and a propellant burning rate low postulated. The propellant burning rate model when coupled with the grain deformation model permits an excellent match between theoretical results and test data for the Titan IIIC, TU455.02, and the first Space Shuttle SRM (DM-1). Analysis of star grain deformation using an experimental model and a finite element model shows the star grain deformation effects for the Space Shuttle to be small in comparison to those of the circular perforated grain. An alternative technique was developed for predicting thrust imbalance without recourse to the Monte Carlo computer program. A scaling relationship used to relate theoretical results to test results may be applied to the alternative technique of predicting thrust imbalance or to the Monte Carlo evaluation. Extended investigation into the effect of strain rate on propellant burning rate leads to the conclusion that the thermoelastic effect is generally negligible for both steadily increasing pressure loads and oscillatory loads.

  20. Issues and challenges associated with classifying neoplasms in percutaneous needle biopsies of incidentally found small renal masses.

    PubMed

    Evans, Andrew J; Delahunt, Brett; Srigley, John R

    2015-03-01

    Percutaneous needle core biopsy has become acceptable for classifying renal tumours and guiding patient management in the setting of an incidentally-detected small renal mass (SRM), defined as an asymptomatic, non-palpable mass <4cm in maximum dimension. Long-held concerns preventing the incorporation of biopsies into routine patient care, including the perception of poor diagnostic yield and risks of complications such as bleeding or biopsy tract seeding, have largely been disproven. While needle biopsies for SRMs have traditionally been performed in academic centres, pathologists based in non-academic centres can expect to encounter these specimens as urologists and/or interventional radiologist trainees complete their training programs and begin work in non-academic centres. This review covers the rationale for performing these biopsies, the expected diagnostic yield, relevant differential diagnoses and an approach to classifying SRMs based on limited samples as well as the use of immunohistochemical (IHC) staining panels to aid in this process. There is also an undeniable learning curve for pathologists faced with reporting these biopsies and a number of issues and potential pitfalls attributable to sampling must be kept in mind by pathologists and clinicians alike. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Effects of vasoactive intestinal peptide on vascular conductance are unaffected by anesthesia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bouder, T.G.; Huffman, L.J.; Hedge, G.A.

    1988-12-01

    In rats anesthetized with ketamine and pentobarbital (KET/PB), vasoactive intestinal peptide (VIP) increases vascular conductance (VC) in the salivary gland, pancreas, and thyroid gland, whereas no changes in VC are observed in a number of other organs. Because anesthesia may alter the responsiveness of physiological systems, we compared the effects of VIP on organ VC in conscious or anesthetized rats. Chronically catheterized rats were studied in the conscious state or 30 min after induction of anesthesia with KET/PB, isoflurane, or Inactin. Blood flows were measured by the reference sample version of the radioactive microsphere (MS) technique using two MS injectionsmore » ({sup 141}Ce-MS/{sup 85}Sr-MS). Mean arterial blood pressure was monitored and used in the calculation of VC. Organ VCs were similar under basal conditions in conscious and anesthetized rats. VIP infusion caused systemic hypotension and increased VCs in the salivary gland, pancreas, and thyroid gland, and these responses were largely unaffected by anesthesia. These results indicate that the anesthetics used do not alter basal VC or the responsiveness of the vasculature to exogenous VIP.« less

  2. Preconcentration and determination of vanadium and molybdenum in milk, vegetables and foodstuffs by ultrasonic-thermostatic-assisted cloud point extraction coupled to flame atomic absorption spectrometry.

    PubMed

    Gürkan, Ramazan; Korkmaz, Sema; Altunay, Nail

    2016-08-01

    A new ultrasonic-thermostatic-assisted cloud point extraction procedure (UTA-CPE) was developed for preconcentration at the trace levels of vanadium (V) and molybdenum (Mo) in milk, vegetables and foodstuffs prior to determination via flame atomic absorption spectrometry (FAAS). The method is based on the ion-association of stable anionic oxalate complexes of V(V) and Mo(VI) with [9-(diethylamino)benzo[a]phenoxazin-5-ylidene]azanium; sulfate (Nile blue A) at pH 4.5, and then extraction of the formed ion-association complexes into micellar phase of polyoxyethylene(7.5)nonylphenyl ether (PONPE 7.5). The UTA-CPE is greatly simplified and accelerated compared to traditional cloud point extraction (CPE). The analytical parameters optimized are solution pH, the concentrations of complexing reagents (oxalate and Nile blue A), the PONPE 7.5 concentration, electrolyte concentration, sample volume, temperature and ultrasonic power. Under the optimum conditions, the calibration curves for Mo(VI) and V(V) are obtained in the concentration range of 3-340µgL(-1) and 5-250µgL(-1) with high sensitivity enhancement factors (EFs) of 145 and 115, respectively. The limits of detection (LODs) for Mo(VI) and V(V) are 0.86 and 1.55µgL(-1), respectively. The proposed method demonstrated good performances such as relative standard deviations (as RSD %) (≤3.5%) and spiked recoveries (95.7-102.3%). The accuracy of the method was assessed by analysis of two standard reference materials (SRMs) and recoveries of spiked solutions. The method was successfully applied into the determination of trace amounts of Mo(VI) and V(V) in milk, vegetables and foodstuffs with satisfactory results. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. An assessment of exposure to rare earth elements among patients receiving long-term parenteral nutrition.

    PubMed

    Galusha, Aubrey L; Kruger, Pamela C; Howard, Lyn J; Parsons, Patrick J

    2018-05-01

    Patients receiving long-term parenteral nutrition (PN) are exposed to potentially toxic elements, which may accumulate in bone. Bone samples collected from seven PN patients (average = 14 years) and eighteen hip/knee samples were analyzed for Al as part of a previous investigation. Yttrium was serendipitously detected in the PN bone samples, leading to the present investigation of rare earth elements (REEs). A method for quantitating fifteen REEs in digested bone was developed based on tandem ICP-MS (ICP-MS/MS) to resolve spectral interferences. The method was validated against nine biological reference materials (RMs) for which assigned values were available for most REEs. Values found in two NIST bone SRMs (1400 Bone Ash and 1486 Bone Meal) compared favorably to those reported elsewhere. Method detection limits ranged from 0.9 ng g -1 (Tm) to 5.8 ng g -1 (Y). Median REE values in the PN patient group were at least fifteen times higher than the "control" group, and exceeded all previously reported data for eleven REEs in human bones. REE content in PN bones normalized to the Earth's upper crust revealed anomalies for Gd in two patients, likely from exposure to Gd-containing contrast agents used in MRI studies. A retrospective review of the medical record for one patient revealed an almost certain case of nephrogenic systemic fibrosis, associated with Gd exposure. Analysis of two current PN formulations showed traces of REEs with relative abundances similar to those found in the PN bones, providing convincing evidence that PN solutions were the primary source of REEs in this population. Copyright © 2018 Elsevier GmbH. All rights reserved.

  4. SRMS maneuvers the ICC-VLD during STS-127 / Expedition 20 Joint Operations

    NASA Image and Video Library

    2009-07-19

    S127-E-006934 (19 July 2009) --- Backdropped by a blue and white Earth, the remote manipulator system (RMS) arm of the Space Shuttle Endeavour, is about to hand off the Integrated Cargo Carrier (ICC) to the International Space Station (out of frame). The ICC is an unpressurized flat bed pallet and keel yoke assembly that was carried into space in the shuttle's payload bay.

  5. Simulating the dynamic interaction of a robotic arm and the Space Shuttle remote manipulator system. M.S. Thesis - George Washington Univ., Dec. 1994

    NASA Technical Reports Server (NTRS)

    Garrahan, Steven L.; Tolson, Robert H.; Williams, Robert L., II

    1995-01-01

    Industrial robots are usually attached to a rigid base. Placing the robot on a compliant base introduces dynamic coupling between the two systems. The Vehicle Emulation System (VES) is a six DOF platform that is capable of modeling this interaction. The VES employs a force-torque sensor as the interface between robot and base. A computer simulation of the VES is presented. Each of the hardware and software components is described and Simulink is used as the programming environment. The simulation performance is compared with experimental results to validate accuracy. A second simulation which models the dynamic interaction of a robot and a flexible base acts as a comparison to the simulated motion of the VES. Results are presented that compare the simulated VES motion with the motion of the VES hardware using the same admittance model. The two computer simulations are compared to determine how well the VES is expected to emulate the desired motion. Simulation results are given for robots mounted to the end effector of the Space Shuttle Remote Manipulator System (SRMS). It is shown that for fast motions of the two robots studied, the SRMS experiences disturbances on the order of centimeters. Larger disturbances are possible if different manipulators are used.

  6. Assessing oral health-related quality of life in general dental practice in Scotland: validation of the OHIP-14.

    PubMed

    Fernandes, Marcelo José; Ruta, Danny Adolph; Ogden, Graham Richard; Pitts, Nigel Berry; Ogston, Simon Alexander

    2006-02-01

    To validate the Oral Health Impact Profile (OHIP)-14 in a sample of patients attending general dental practice. Patients with pathology-free impacted wisdom teeth were recruited from six general dental practices in Tayside, Scotland, and followed for a year to assess the development of problems related to impaction. The OHIP-14 was completed at baseline and at 1-year follow-up, and analysed using three different scoring methods: a summary score, a weighted and standardized score and the total number of problems reported. Instrument reliability was measured by assessing internal consistency and test-retest reliability. Construct validity was assessed using a number of variables. Linear regression was then used to model the relationship between OHIP-14 and all significantly correlated variables. Responsiveness was measured using the standardized response mean (SRM). Adjusted R(2)s and SRMs were calculated for each of the three scoring methods. Estimates for the differences between adjusted R(2)s and the differences between SRMs were obtained with 95% confidence intervals. A total of 278 and 169 patients completed the questionnaire at baseline and follow-up, respectively. Reliability - Cronbach's alpha coefficients ranged from 0.30 to 0.75. Alpha coefficients for all 14 items were 0.88 and 0.87 for baseline and follow-up, respectively. Test-retest coefficients ranged from 0.72 to 0.78. Validity - OHIP-14 scores were significantly correlated with number of teeth, education, main activity, the use of mouthwash, frequency of seeing a dentist, the reason for the last dental appointment, smoking, alcohol intake, pain and symptoms. Adjusted R(2)s ranged from 0.123 to 0.202 and there were no statistically significant differences between those for the three different scoring methods. Responsiveness - The SRMs ranged from 0.37 to 0.56 and there was a statistically significant difference between the summary scores method and the total number of problems method for symptomatic patients. The OHIP-14 is a valid and reliable measure of oral health-related quality of life in general dental practice and is responsive to third molar clinical change. The summary score method demonstrated performance as good as, or better than, the other methods studied.

  7. Endeavour SRMS / OBSS during Survey OPS

    NASA Image and Video Library

    2010-02-09

    S130-E-005338 (8 Feb. 2010) --- Backdropped by the South China Sea and the Gulf of Tonkin, the Tranquility node in space shuttle Endeavour’s payload bay, vertical stabilizer, orbital maneuvering system (OMS) pods and a shadow-covered docking mechanism are featured in this image photographed by the STS-130 crew from an aft flight deck window. Hainan Island can be seen between the South China Sea (bottom) and Gulf of Tonkin (top). The Leizhou Peninsula of the Chinese mainland is on the upper right.

  8. [Laboratory diagnosis of mucormycosis].

    PubMed

    Garcia-Hermoso, Dea

    2013-03-01

    Mucormycosis are deep infections caused by ubiquitous filamentous fungi of the order of Mucorales. The disease occurs mostly in immunocompromised, diabetic or solid organ transplant recipients. There are currently no specific diagnostic guidelines for mucormycosis. The histological examination and culture of the clinical sample remain the most useful approaches for diagnosis. Furthermore, alternative methods to the fungal culture are yet to be standardized. Here we review the current microbiological approaches used for the diagnosis and identification of Mucorales. © 2013 médecine/sciences – Inserm / SRMS.

  9. [Ethics of biomedical research: questions about patient information].

    PubMed

    Moutel, Grégoire

    2013-02-01

    All recommendations and laws concerning biomedical research, including the most recent in France in 2012, emphasize the quality of patient information to justify its participation. To optimize practices, it is important to take into account the central issues: what limits of information? What role for the relatives and family in the decision in case of disability or vulnerability of a patient? What need for specific information for long protocol and follow-up cohort? What information about research results? © 2013 médecine/sciences – Inserm / SRMS.

  10. Multi-scale analysis of the occurrence of Pb, Cr and Mn in the NIST standards: Urban dust (SRM 1649a) and indoor dust (SRM 2584)

    NASA Astrophysics Data System (ADS)

    Jiang, Mingyu; Nakamatsu, Yuki; Jensen, Keld A.; Utsunomiya, Satoshi

    2014-01-01

    Adverse health effects of ambient particulate matters are closely related to the speciation of the constituting organic matters and toxic metals. To determine multi-parameters of the metal speciation in urban and indoor dusts, we have performed systematic bulk- to nano-scale (“multi-scale”) analysis on the speciation of Pb, Mn, and Cr in two National Institute of Standards and Technology (NIST) standard reference materials (SRMs): urban dust (SRM 1649a) and indoor dust (SRM 2584), utilizing X-ray absorption near-edge structure, powder X-ray diffraction analysis, electron microprobe analysis, scanning electron microscopy, and transmission electron microscopy. Major crystalline phases are quartz, gypsum, kaolinite, and muscovite in SRM 1649a, while quartz, gypsum, calcite, and possibly muscovite (or chabazite) in SRM 2584. A number of Pb sulfate nanoparticles (50-200 nm) occur in SRM 1649a, whereas micron-sized Pb carbonate is present containing various concentrations of Zn and Ti in the complex texture in SRM 2584. Relatively soluble Mn(II) sulfate is the bulk-averaged Mn speciation in SRM 1649a, although discrete Mn sulfate particles are not characterized by individual particle analysis, implying the diluted Mn distribution within other sulfate. In SRM 2584, Mn speciation includes a mixture of oxides and carbonates, and trace Mn in chromite. Chromite (FeCr2O4) is the major Cr speciation in SRM1694a, while unidentified Cr(III) phases with minor chromite and Pb chromate are present in SRM 2584, among which the Pb chromate is composed of Cr(VI). A significant number of the metal-bearing particles are distributed to the submicron-size fraction in the urban dust, SRM 1649a, suggesting that these metal nanoparticles can potentially penetrate into the deep respiratory system. This study demonstrates that multi-scale analysis combining nano and bulk analytical techniques is a powerful approach to investigate the multi-parameters of metal-bearing nanoparticles in heterogeneous PM samples.

  11. Determination of sub-ng g-1 levels of total inorganic arsenic and selenium in foods by hydride-generation atomic absorption spectrometry after pre-concentration.

    PubMed

    Altunay, Nail; Gürkan, Ramazan

    2017-03-01

    A new and simple ultrasonic-assisted extraction (UAE) procedure was developed for the determination of inorganic arsenic and selenium in foods by hydride-generation atomic absorption spectrometry (HG-AAS). The various analytical variables affecting complex formation and extraction efficiency were investigated and optimised. The method is based on selective complex formation of As(III) and Se(IV) in the presence of excess As(V) and Se(VI) with toluidine red in the presence of tartaric acid at pH 4.5, and then extraction of the resulting condensation products into the micellar phase of non-ionic surfactant, polyethylene glycol dodecyl ether, Brij 35. Under optimised conditions, good linear relationships were obtained in the ranges of 4-225 and 12-400 ng l - 1 with limits of detection of 1.1 and 3.5 ng l - 1 for As(III) and Se(IV), respectively. The repeatability was better than 3.9% for both analytes (n = 10, 25 ng l - 1 ) while reproducibility ranged from 4.2% to 4.8%. The recoveries of As(III) and Se(IV) spiked at 25-100 ng l - 1 were in the range of 94.2-104.8%. After pre-concentration of a 5.0 ml sample, the sensitivity enhancement factors for As(III) and Se(IV) were 185 and 140, respectively. Accuracy was assessed by analysis of two standard reference materials (SRMs) and spiked recovery experiments. The method was successfully applied to the accurate and reliable determination of total As and total Se by HG-AAS after pre-reduction with a mixture of L-cysteine and tartaric acid. Finally, the method was shown to be rapid and sensitive, with good results for extraction, pre-concentration and determination of total As and Se contents (as As(III) and Se(IV)) from food samples.

  12. Preparation and application of a tyre-based activated carbon solid phase extraction of heavy metals in wastewater samples

    NASA Astrophysics Data System (ADS)

    Dimpe, K. Mogolodi; Ngila, J. C.; Nomngongo, Philiswa N.

    2018-06-01

    In this paper, the tyre-based activated carbon solid phase extraction (SPE) method was successfully developed for simultaneous preconcentration of metal ions in the model and real water samples before their determination using flame atomic absorption spectrometry (FAAS). The activation of carbon was achieved by chemical activation and the tyre-based activated carbon was used as a sorbent for solid phase extraction. The prepared activated carbon was characterized using the scanning electron microscope (SEM), Brunauer-Emmett-Teller (BET), and Fourier Transform Infrared spectroscopy. Moreover, optimization of the proposed method was performed by the two-level full factorial design (FFD). The FFD was chosen in order to fully investigate the effect of the experimental variables (pH, eluent concentration and sample flow rate) that significantly influence the preconcentration procedure. In this model, individual factors are considered along with their interactions. In addition, modelling of the experiments allowed simultaneous variation of all experimental factors investigated, reduced the required time and number of experimental runs which consequently led to the reduction of the overall required costs. Under optimized conditions, the limits of detection and quantification (LOD and LOQ) ranged 0.66-2.12 μg L-1and 1.78-5.34 μg L-1, respectively and the enrichment factor of 25 was obtained. The developed SPE/FAAS method was validated using CWW-TM-A and CWW-TM-B wastewater standard reference materials (SRMs). The procedure showed to be accurate with satisfactory recoveries ranging from 92 to 99%. The precision (repeatability) was lower than 4% in terms of the relative standard deviation (%RSD). The developed method proved to have the capability to be used in routine analysis of heavy metals in domestic and industrial wastewater samples. In addition, the developed method can be used as a final step (before being discharged to the rivers) in wastewater treatment process in order to keep our water bodies free from toxic metals.

  13. A simple and efficient ultrasonic-assisted extraction procedure combined with UV-Vis spectrophotometry for the pre-concentration and determination of folic acid (vitamin B9) in various sample matrices.

    PubMed

    Gürkan, Ramazan; Altunay, Nail

    2016-07-01

    A simple and efficient ultrasonic-assisted extraction (UAE) procedure has been proposed for the pre-concentration of (2S)-2-[(4-{[(2-amino-4-hydroxypteridin-yl)methyl]amino}phenyl)formamido]pentanedioic acid (folic acid) in vegetables, pharmaceuticals and foods prior to determination at 540 nm using UV-Vis spectrophotometry. The method is based on hydrophobic ternary complex formation of folic acid with silver ions in the presence of cetyltrimethylammonium bromide (CTAB) as a sensitivity enhancer counter ion at pH 7.0, and then extraction into a micellar phase of polyethylene glycol monoalkyl ether (Genapol X-080). The impacts on the extraction efficiency and complex formation of analytical parameters such as sample pH, concentration of silver, concentration of surfactants and extraction time, ultrasonic time and sample volume, were investigated and optimised in detail. The matrix effect on the pre-concentration and determination of folic acid was investigated, and it was observed that the proposed method was highly selective against possible matrix co-extractives. Under optimised conditions, a good linear relationship between the analytical signal and folic acid concentration was obtained in the range of 0.6-180 μg l(-1) with a detection limit of 0.19 μg l(-1) and quantification limit of 0.63 μg l(-1). The applicability was evaluated using samples fortified at different concentration levels, and recoveries higher than 94.1% were obtained. The precision as the percent relative standard deviation (RSD%) was in range of 2.5-3.8% (10 and 40 μg l(-1), n = 5). The proposed method was validated by analysis of two standard reference materials (SRMs) and various real samples, and satisfactory results were obtained.

  14. Ablation characteristics and reaction mechanism of insulation materials under slag deposition condition

    NASA Astrophysics Data System (ADS)

    Guan, Yiwen; Li, Jiang; Liu, Yang

    2017-07-01

    Current understanding of the physical and chemical processes involved in the ablation of insulation materials by highly aluminized solid propellants is limited. The study on the heat transfer and ablation principle of ethylene propylene diene monomer (EPDM) materials under slag deposition condition is essential for future design or modification of large solid rocket motors (SRMs) for launch application. In this paper, the alumina liquid flow pattern and the deposition principle in full-scale SRM engines are discussed. The interaction mechanism between the alumina droplets and the wall are analyzed. Then, an experimental method was developed to simulate the insulation material ablation under slag deposition condition. Experimental study was conducted based on a laboratory-scale device. Meanwhile, from the analysis of the cross-sectional morphology and chemical composition of the charring layer after ablation, the reaction mechanism of the charring layer under deposition condition was discussed, and the main reaction equation was derived. The numerical simulation and experimental results show the following. (i) The alumina droplet flow in the deposition section of the laboratory-scale device is similar to that of a full-scale SRM. (ii) The charring layer of the EPDM insulator displays a porous tight/loose structure under high-temperature slag deposition condition. (iii) A seven-step carbothermal reduction in the alumina is derived and established under high-pressure and high-temperature environment in the SRM combustion chamber. (iv) The analysis using thermodynamic software indicates that the reaction of the alumina and charring layer initially forms Al4C3 during the operation. Then, Al element and Al2OC compound are subsequently produced with the reduction in the release of gas CO as well with continuous environmental heating.

  15. Study of solid rocket motors for a space shuttle booster. Appendix C: Recovery and reuse 120-inch diameter solid rocket motor boosters

    NASA Technical Reports Server (NTRS)

    1972-01-01

    A baseline for a space shuttle configuration utilizing four parallel-burn 120-in. diameter SRMS is presented. Topics discussed include parachute system sequence, recovery system development profile, parachute container, and segment and closure recovery operations. A cost analysis for recovery of the SRM stage is presented. It is concluded that from the standpoint of minimum cost and development, parachutes are the best means of achieving SRM recovery. Major SRM components can be reused safely.

  16. [Nuclear-power-plant accidents: thyroid cancer incidence and radiation-related health effects from the Chernobyl accident].

    PubMed

    Schlumberger, Martin; Le Guen, Bernard

    2012-01-01

    Following the Chernobyl accident, enormous amounts of radioisotopes were released in the atmosphere and have contaminated surrounding populations in the absence of rapid protective countermeasures. The highest radiation doses were delivered to the thyroid gland, and the only direct consequence of radiation exposure observed among contaminated population is the increased incidence of thyroid cancers among subjects who were children in 1986 and who lived at that time in Belarus, Ukraine or Russia. © 2012 médecine/sciences – Inserm / SRMS.

  17. [Mesenchymal stem cells: weapons or dangers for cancer treatment?].

    PubMed

    Lazennec, Gwendal

    2011-03-01

    Mesenchymal stem cells (MSC) have attracted recent attention for their cell therapy potential, based in particular on their immunosuppressive properties, which have served as the basis for the treatment of autoimmune diseases. Interestingly, MSC have been used in cell therapy strategies to deliver therapeutical genes. Cell therapy approaches taking advantages of MSC have been proposed, as MSC display a potential tropsim for tumors. However, all these strategies raise a series of questions about the safety of MSC, as MSC could enhance tumor growth and metastasis. This review summarizes recent findngs about MSC in carcinogenesis. © 2011 médecine/sciences - Inserm / SRMS.

  18. Improvements to the Tendon-Actuated Lightweight In-Space MANipulator (TALISMAN)

    NASA Technical Reports Server (NTRS)

    Doggett, William R.; Dorsey, John T.; Jones, Thomas C.; Lodding, Kenneth N.; Ganoe, George G.; Mercer, David; King, Bruce D.

    2015-01-01

    Devices for manipulating and precisely placing payloads are critical for efficient space operations including berthing of spacecraft, in-space assembly, construction and repair. Key to the success of many NASA space activities has been the availability of long-reach crane-like devices such as the Shuttle Remote Manipulation System (SRMS) and the Space Station Remote Manipulation System (SSRMS). These devices have been used for many operations including berthing visiting spacecraft to the International Space Station, deployment of spacecraft, space station assembly, astronaut positioning, payload transfer, and spacecraft inspection prior to atmospheric re-entry. Retiring the Space Transportation System has led to the removal of the SRMS from consideration for in-space missions, thus creating a capability gap. Recognizing this gap, work was initiated at NASA on a new architecture for long-reach space manipulators. Most current devices are constructed by joining revolute joints with carbon composite tubes, with the joints accounting for the majority of the device mass. For example in the case of the SRMS, the entire device mass is 410 kg (904 lbm); the joint structure, motors, gear train, cabling, etc., accounts for the majority of the system mass because the carbon composite tubes mass is 46 kg (101 lbm). An alternate space manipulator concept, the Tendon-Actuated Lightweight In-Space MANipulator (TALISMAN) was created to address deficiencies in the current state-of-the-art in long-reach manipulators. The antagonistic tendon actuated joint architecture allows the motors actuating the joint to be removed from the joint axis, which simplifies the joint design while simultaneously providing mechanical advantage for the motors. The improved mechanical advantage, in turn, reduces the size and power requirements for the motor and gear train. This paper will describe recent architectural improvements to the TALISMAN design that: 1) improve the operational robustness of the system by enabling maneuvers not originally possible by varying the TALISMAN geometry; 2) enable efficient active antagonistic control of a joint while sharing cable between antagonistic tension networks; and 3) uses a unique arrangement of differential capstans to reduce motor torque requirements by an order of magnitude. The paper will also summarize recent efforts to enable autonomous deployment of a TALISMAN including the deployment concept of operations and associated hardware system design. The deployment forces are provided by the same motor systems that are used for articulation, thus reducing the mass associated with the deployment system. The deployment approach is being tested on a TALISMAN prototype which is designed to provide the same operational performance as a shuttle-class manipulator. The prototype has been fabricated and is operational in a new facility at NASA Langley Research Center that has a large area (15.2 m by 21.3 m [50 ft by 70 ft]) air-bearing floor.

  19. Coupled Solid Rocket Motor Ballistics and Trajectory Modeling for Higher Fidelity Launch Vehicle Design

    NASA Technical Reports Server (NTRS)

    Ables, Brett

    2014-01-01

    Multi-stage launch vehicles with solid rocket motors (SRMs) face design optimization challenges, especially when the mission scope changes frequently. Significant performance benefits can be realized if the solid rocket motors are optimized to the changing requirements. While SRMs represent a fixed performance at launch, rapid design iterations enable flexibility at design time, yielding significant performance gains. The streamlining and integration of SRM design and analysis can be achieved with improved analysis tools. While powerful and versatile, the Solid Performance Program (SPP) is not conducive to rapid design iteration. Performing a design iteration with SPP and a trajectory solver is a labor intensive process. To enable a better workflow, SPP, the Program to Optimize Simulated Trajectories (POST), and the interfaces between them have been improved and automated, and a graphical user interface (GUI) has been developed. The GUI enables real-time visual feedback of grain and nozzle design inputs, enforces parameter dependencies, removes redundancies, and simplifies manipulation of SPP and POST's numerous options. Automating the analysis also simplifies batch analyses and trade studies. Finally, the GUI provides post-processing, visualization, and comparison of results. Wrapping legacy high-fidelity analysis codes with modern software provides the improved interface necessary to enable rapid coupled SRM ballistics and vehicle trajectory analysis. Low cost trade studies demonstrate the sensitivities of flight performance metrics to propulsion characteristics. Incorporating high fidelity analysis from SPP into vehicle design reduces performance margins and improves reliability. By flying an SRM designed with the same assumptions as the rest of the vehicle, accurate comparisons can be made between competing architectures. In summary, this flexible workflow is a critical component to designing a versatile launch vehicle model that can accommodate a volatile mission scope.

  20. Comparison of SF-36 vitality scale and Fatigue Symptom Inventory in assessing cancer-related fatigue.

    PubMed

    Brown, Linda F; Kroenke, Kurt; Theobald, Dale E; Wu, Jingwei

    2011-08-01

    Cancer-related fatigue (CRF) is an important symptom in clinical practice and research. The best way to measure it, however, remains unsettled. The SF-36 vitality scale, a general measure of energy/fatigue, is a frequently cited measure. With only four items, however, its ability to adequately represent multiple CRF facets has been questioned. The 13-item Fatigue Symptom Inventory (FSI) was developed to assess multidimensional aspects of CRF. Our objectives were to assess the convergent validity and to compare the sensitivity to change of the two scales. We administered both scales at 1 month (n = 68) and 6 months (n = 96) to a subset of heterogeneous patients receiving treatment in 16 cancer centers who were enrolled in a clinical trial of pain and depression. Distributions of standardized response means (SRMs) were compared to assess sensitivity to change. Results of both scales were compared to scores on a single fatigue item from the Patient Health Questionnaire (PHQ). Mean scores for both the FSI and the vitality scale demonstrated clinically significant fatigue in the sample. The vitality scale was strongly correlated with all three FSI scales (r = -0.68 to -0.77). The vitality and FSI scales also correlated strongly with the PHQ fatigue item. Moreover, distributions of SRMs for both scales were approximately normal. Both the FSI and the vitality scale are supported as valid measures of CRF. Both demonstrated sensitivity to change across a range of effect sizes. The vitality scale may be an excellent choice when brevity is paramount; the FSI may be more appropriate when tapping specific dimensions is warranted.

  1. Advantages of reaction cell ICP-MS on doubly charged interferences for arsenic and selenium analysis in foods

    PubMed Central

    Jackson, Brian; Liba, Amir; Nelson, Jenny

    2014-01-01

    Recent reports of As concentrations in certain food and drinks have garnered public concern and led to a lowering of the US guideline maximum concentration for inorganic As in apple juice and proposed limits for As in rice products. In contrast Se is an essential micro-nutrient that can be limiting when Se-poor soils yield Se-poor food crops. Rare earth element (REE) doubly charged interferences on As and Se can be significant even when initial ICP-MS tuning minimizes doubly charged formation. We analyzed NIST 1547 (peach leaves) and 1515 (apple leaves), which contain high levels of REEs, by quadrupole ICP-MS with (He) collision mode, H2 reaction mode or triple quadrupole ICP-MS (ICP-QQQ) in mass-shift mode (O2 and O2/H2). Analysis by collision cell ICP-MS significantly over-estimated As and Se concentration due to REE doubly charged formation; mathematical correction increased the accuracy of analysis but is prone to error when analyte concentration and sensitivity is low and interferent is high. For Se, H2 reaction mode was effective in suppressing Gd2+ leading to accurate determination of Se in both SRMs without the need for mathematical correction. ICP-QQQ using mass-shift mode for As+ from m/z 75 to AsO+ at m/z 91 and Se+ from m/z 78 to SeO+ at m/z 94 alleviated doubly charged effects and resulted in accurate determination of As and Se in both SRMs without the need for correction equations. Zr and Mo isobars at 91 and 94 were shown to be effectively rejected by the MS/MS capability of the ICP-QQQ. PMID:25609851

  2. Orbiter Repair Maneuver Contingency Separation Methods and Analysis

    NASA Technical Reports Server (NTRS)

    Machula, Michael

    2005-01-01

    Repairing damaged thermal protection system tile requires the Space Shuttle to be oriented such that repair platform access from the International Space Station (ISS) is possible. To do this, the Space Shuttle uses the Orbiter Repair Maneuver (ORM), which utilizes the Shuttle Remote Manipulator System (SRMS) to rotate the Space Shuttle in relation to the ISS, for extended periods of time. These positions cause difficulties and challenges to performing a safe separation (no collision or thruster plume damage to sensitive ISS structures) should an inadvertent release occur or a contingency procedure require it. To help protect for an SRMS failure or other failures, a method for separating without collision and the ability to redock to ISS from the ORM configuration was needed. The contingency ORM separation solution elegantly takes advantage of orbital mechanics between ISS and the separating Space Shuttle. By pitching the ISS down approximately 45 degrees, in a majority of the ORM repair positions, the altitude difference between the ISS and Space Shuttle center of gravity is maximized. This altitude difference results in different orbital energies (orbital periods) causing objects to separate from each other without requiring translational firings. Using this method, a safe contingency ORM separation is made possible in many odd positions even though some separation positions point high powered thrusters directly at fragile ISS and Soyuz solar arrays. Documented in this paper are the development simulations and procedures of the contingency ORM separation and the challenges encountered with large constraints to work around. Lastly, a method of returning to redock with the ISS to pick up the stranded crew members (or transfer the final crew members) is explained as well as the thruster and ISS loads analysis.

  3. A new two-phase homopolar switched reluctance motor for electric vehicle applications

    NASA Astrophysics Data System (ADS)

    Tsai, Mi-Ching; Huang, Chien-Chin; Huang, Zheng-Yi

    2003-12-01

    This paper presents a novel 2-phase homopolar switched reluctance motor (SRM), whose design successfully avoids dead-zone problems that afflict low cost 1- and/or 2-phase SRMs. Unlike conventional radial-winding-radial-gap motors, the proposed SRM has an interior stator that is of the pancake type with axial winding. Such a design allows for a high slot-fill factor and is suitable for implementation as a flat pancake-shaped stator. An efficient, compact prototype was produced with TMS320F240 DSP driving control unit. Experimental results indicate that the present SRM design has the potential to be used for electric bicycles and scooters.

  4. Multivariable control of the Space Shuttle Remote Manipulator System using linearization by state feedback. M.S. Thesis

    NASA Technical Reports Server (NTRS)

    Gettman, Chang-Ching LO

    1993-01-01

    This thesis develops and demonstrates an approach to nonlinear control system design using linearization by state feedback. The design provides improved transient response behavior allowing faster maneuvering of payloads by the SRMS. Modeling uncertainty is accounted for by using a second feedback loop designed around the feedback linearized dynamics. A classical feedback loop is developed to provide the easy implementation required for the relatively small on board computers. Feedback linearization also allows the use of higher bandwidth model based compensation in the outer loop, since it helps maintain stability in the presence of the nonlinearities typically neglected in model based designs.

  5. Remote Manipulator System (RMS)-based Controls-Structures Interaction (CSI) flight experiment feasibility study

    NASA Technical Reports Server (NTRS)

    Demeo, Martha E.

    1990-01-01

    The feasibility of an experiment which will provide an on-orbit validation of Controls-Structures Interaction (CSI) technology, was investigated. The experiment will demonstrate the on-orbit characterization and flexible-body control of large flexible structure dynamics using the shuttle Remote Manipulator System (RMS) with an attached payload as a test article. By utilizing existing hardware as well as establishing integration, operation and safety algorithms, techniques and procedures, the experiment will minimize the costs and risks of implementing a flight experiment. The experiment will also offer spin-off enhancement to both the Shuttle RMS (SRMS) and the Space Station RMS (SSRMS).

  6. Effect of Transitioning from Standard Reference Material 2806a to Standard Reference Material 2806b for Light Obscuration Particle Countering

    DTIC Science & Technology

    2016-04-01

    Reference Material 2806b for Light Obscuration Particle Countering April 2016 UNCLASSIFIED UNCLASSIFIED Joel Schmitigal 27809 Standard Form 298 (Rev...Standard Reference Material 2806b for Light Obscuration Particle Countering 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6...Reference Material 2806a to Standard Reference Material 2806b for Light Obscuration Particle Countering Joel Schmitigal Force Projection

  7. Recent developments in the field of environmental reference materials at the JRC Ispra.

    PubMed

    Muntau, H

    2001-06-01

    The production of reference materials for environmental analysis started in the Joint Research Centre at Ispra/Italy in 1972 with the objective of later certification by the BCR, but for obvious budget reasons only a fraction of the total production achieved at Ispra ever reached certification level, although all materials were produced according to the severe quality requirements requested for certified reference materials. Therefore, the materials not destinated to certification are in growing demand as inter-laboratory test materials and as laboratory reference materials, for internal quality control, e.g., by control charts. The history of reference material production within the Joint Research Centre is briefly reviewed and the latest additions described. New developments such as micro-scale reference materials intended for analytical methods requiring sample intakes at milligram or sub-milligram level and therefor not finding supply on the reference material market, and "wet" environmental reference materials, which meet more precisely the "real-world" environmental analysis conditions, are presented and the state-of-the-art discussed.

  8. PMA-2 and SRMS/OBSS during Expedition 18 / STS-126 Joint Operations

    NASA Image and Video Library

    2008-11-26

    S126-E-011973 (26 Nov. 2008) --- The Canadian-built Orbiter Boom Sensor System (OBSS), in its parked position, and part of the International Space Station are featured in this image, photographed over the Blue Ridge Mountains of West Virginia and Tennessee by one of the Endeavour crew members on the eve of Thanksgiving. The OBSS, on the end of the Canadarm, awaits the final part of its STS-126 role when it will inspect the shuttle one more time, following separation of the orbiter from the space station in a couple of days. When that task is complete, it will be stowed across the payload bay from the robot arm.

  9. Dynamic Simulation of VEGA SRM Bench Firing By Using Propellant Complex Characterization

    NASA Astrophysics Data System (ADS)

    Di Trapani, C. D.; Mastrella, E.; Bartoccini, D.; Squeo, E. A.; Mastroddi, F.; Coppotelli, G.; Linari, M.

    2012-07-01

    During the VEGA launcher development, from the 2004 up to now, 8 firing tests have been performed at Salto di Quirra (Sardinia, Italy) and Kourou (Guyana, Fr) with the objective to characterize and qualify of the Zefiros and P80 Solid Rocket Motors (SRM). In fact the VEGA launcher configuration foreseen 3 solid stages based on P80, Z23 and Z9 Solid Rocket Motors respectively. One of the primary objectives of the firing test is to correctly characterize the dynamic response of the SRM in order to apply such a characterization to the predictions and simulations of the VEGA launch dynamic environment. Considering that the solid propellant is around 90% of the SRM mass, it is very important to dynamically characterize it, and to increase the confidence in the simulation of the dynamic levels transmitted to the LV upper part from the SRMs. The activity is articulated in three parts: • consolidation of an experimental method for the dynamic characterization of the complex dynamic elasticity modulus of elasticity of visco-elastic materials applicable to the SRM propellant operative conditions • introduction of the complex dynamic elasticity modulus in a numerical FEM benchmark based on MSC NASTRAN solver • analysis of the effect of the introduction of the complex dynamic elasticity modulus in the Zefiros FEM focusing on experimental firing test data reproduction with numerical approach.

  10. LLE Review Quarterly Report (January-March 2002). Volume 90

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Donaldson, William R.

    2002-03-01

    This volume of the LLE Review, covering January-March 2002, features “First Results from Cryogenic Target Implosions on OMEGA” by C. Stoeckl et al. (p. 49). This article describes initial results from direct-drive spherical cryogenic target implosions on the 60-beam OMEGA laser system. These experiments are part of the scientific base leading to direct-drive ignition implosions planned for the National Ignition Facility (NIF). Results shown include neutron yield, secondary-neutron and proton yields, the time of peak neutron emission, and both time-integrated and time-resolved x-ray images of the imploding core. The experimental values are compared with 1-D numerical simulations. The target withmore » an ice-layer nonuniformity of srms = 9 mm showed 30% of the 1-D predicted neutron yield. These initial results are encouraging for future cryogenic implosions on OMEGA and the NIF. Other articles in this issue are titled the following: Equation-of-State Measurements of Porous Materials on OMEGA: Numerical Modeling; Observations of Modulated Shock Waves in Solid Targets Driven by Spatially Modulated Laser Beams; Time-Dependent Electron Thermal Flux Inhibition in direct-Drive Laser Implosions; Precision Spectral Sculpting of Broadband FM Pulses Amplified in a Narrowband Medium; Electric-Field-Induced Motion of Polymer Cholesteric Liquid Crystal Flakes in a Moderately Conductive Fluid; and, Femtosecond Response of a Freestanding LT-GaAs Photoconductive Switch.« less

  11. Is the pain visual analogue scale linear and responsive to change? An exploration using Rasch analysis.

    PubMed

    Kersten, Paula; White, Peter J; Tennant, Alan

    2014-01-01

    Pain visual analogue scales (VAS) are commonly used in clinical trials and are often treated as an interval level scale without evidence that this is appropriate. This paper examines the internal construct validity and responsiveness of the pain VAS using Rasch analysis. Patients (n = 221, mean age 67, 58% female) with chronic stable joint pain (hip 40% or knee 60%) of mechanical origin waiting for joint replacement were included. Pain was scored on seven daily VASs. Rasch analysis was used to examine fit to the Rasch model. Responsiveness (Standardized Response Means, SRM) was examined on the raw ordinal data and the interval data generated from the Rasch analysis. Baseline pain VAS scores fitted the Rasch model, although 15 aberrant cases impacted on unidimensionality. There was some local dependency between items but this did not significantly affect the person estimates of pain. Daily pain (item difficulty) was stable, suggesting that single measures can be used. Overall, the SRMs derived from ordinal data overestimated the true responsiveness by 59%. Changes over time at the lower and higher end of the scale were represented by large jumps in interval equivalent data points; in the middle of the scale the reverse was seen. The pain VAS is a valid tool for measuring pain at one point in time. However, the pain VAS does not behave linearly and SRMs vary along the trait of pain. Consequently, Minimum Clinically Important Differences using raw data, or change scores in general, are invalid as these will either under- or overestimate true change; raw pain VAS data should not be used as a primary outcome measure or to inform parametric-based Randomised Controlled Trial power calculations in research studies; and Rasch analysis should be used to convert ordinal data to interval data prior to data interpretation.

  12. Modeling of Dust Levels Associated with Potential Utility-Scale Solar Development in the San Luis Valley-Taos Plateau Study Area

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chang, Y. -S.; Kotamarthi, R.; Hartmann, H. M.

    The San Luis Valley (SLV)–Taos Plateau study area in south-central Colorado and north-central New Mexico is a large alpine valley surrounded by mountains with an area of approximately 6,263,000 acres (25,345 km 2) (Figure ES.1-1). This area receives ample sunshine throughout the year, making it an ideal location for solar energy generation, and there are currently five photovoltaic facilities operating on private lands in the SLV, ranging in capacity from 1 to 30 megawatt (MW). In 2012 the Bureau of Land Management (BLM) launched its Solar Energy Program, which included the identification of four solar energy zones (SEZs) in themore » SLV totaling 16,308 acres (66 km 2), as well as over 50,000 (202 km 2) acres of other BLM-administered lands potentially available for application for solar development. The SEZ areas, named Antonito Southeast, De Tilla Gulch, Fourmile East, and Los Mogotes East, were defined by the BLM as areas well-suited for utility-scale (i.e., larger than 20 MW) production of solar energy where solar energy development would be prioritized (BLM 2012). Nonetheless, it was recognized that solar development in the SEZs would result in some unavoidable adverse impacts, and so the BLM initiated a solar regional mitigation strategy (SRMS) study for three of the SEZs (BLM and Argonne 2016). The SRMS is designed to identify residual impacts of solar development in the SEZs (that is, those that cannot be avoided or minimized onsite), identify those residual impacts that warrant compensatory mitigation when considering the regional status and trends of the resources, identify appropriate regional compensatory mitigation locations and actions to address those residual impacts, and recommend appropriate fees to implement those compensatory mitigation measures.« less

  13. Nuclear reference materials to meet the changing needs of the global nuclear community

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martin, H.R.; Gradle, C.G.; Narayanan, U.I.

    New Brunswick Laboratory (NBL) serves as the U.S. Government`s certifying authority for nuclear reference materials and measurement calibration standards. In this role, NBL provides nuclear reference materials certified for chemical and/or isotopic compositions traceable to a nationally accepted, internationally compatible reference base. Emphasis is now changing as to the types of traceable nuclear reference materials needed as operations change within the Department of Energy complex and at nuclear facilities around the world. New challenges include: environmental and waste minimization issues, facilities and materials transitioning from processing to storage modes with corresponding changes in the types of measurements being performed, emphasismore » on requirements for characterization of waste materials, and difficulties in transporting nuclear materials and international factors, including IAEA influences. During these changing times, it is critical that traceable reference materials be provided for calibration or validation of the performance of measurement systems. This paper will describe actions taken and planned to meet the changing reference material needs of the global nuclear community.« less

  14. 40 CFR 1068.95 - What materials does this part reference?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... material from the Society of Automotive Engineers that we have incorporated by reference. The first column... reference it. Anyone may purchase copies of these materials from the Society of Automotive Engineers, 400... Materials Document number and name Part 1068reference SAE J1930, Electrical/Electronic Systems Diagnostic...

  15. 40 CFR 1068.95 - What materials does this part reference?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... material from the Society of Automotive Engineers that we have incorporated by reference. The first column... reference it. Anyone may purchase copies of these materials from the Society of Automotive Engineers, 400... Materials Document number and name Part 1068reference SAE J1930, Electrical/Electronic Systems Diagnostic...

  16. 40 CFR 1042.910 - Reference materials.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Reference materials. 1042.910 Section... Other Reference Information § 1042.910 Reference materials. Documents listed in this section have been... information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov...

  17. 40 CFR 1042.910 - Reference materials.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 33 2014-07-01 2014-07-01 false Reference materials. 1042.910 Section... Other Reference Information § 1042.910 Reference materials. Documents listed in this section have been... information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov...

  18. 40 CFR 1043.100 - Reference materials.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 33 2014-07-01 2014-07-01 false Reference materials. 1043.100 Section... § 1043.100 Reference materials. Documents listed in this section have been incorporated by reference into... the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov...

  19. A multi-mode manipulator display system for controlling remote robotic systems

    NASA Technical Reports Server (NTRS)

    Massimino, Michael J.; Meschler, Michael F.; Rodriguez, Alberto A.

    1994-01-01

    The objective and contribution of the research presented in this paper is to provide a Multi-Mode Manipulator Display System (MMDS) to assist a human operator with the control of remote manipulator systems. Such systems include space based manipulators such as the space shuttle remote manipulator system (SRMS) and future ground controlled teleoperated and telescience space systems. The MMDS contains a number of display modes and submodes which display position control cues position data in graphical formats, based primarily on manipulator position and joint angle data. Therefore the MMDS is not dependent on visual information for input and can assist the operator especially when visual feedback is inadequate. This paper provides descriptions of the new modes and experiment results to date.

  20. [The substance experience, a history of LSD].

    PubMed

    Beck, François; Bonnet, Nicolas

    2013-04-01

    This article reviews the recent knowledge on LSD stemming from various disciplines among which pharmacology, sociology and epidemiology. The d-lysergic acid diethylamide (LSD) is a particularly powerful hallucinogenic substance. It produces distortions and hearing, visual and tactile hallucinations. Rarely used (only 1.7% of people aged 15-64 years old have tried it in their lifetime), this very powerful drug generates a strong apprehension within the general population, but the ethnographical studies show that its image seems rather good among illicit drug users. This representation relies both on the proper effects of this substance and also on the history of LSD very closely linked to the counterculture characteristic of the years 1960-1970. © 2013 médecine/sciences – Inserm / SRMS.

  1. Nuclear reference materials to meet the changing needs of the global nuclear community

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martin, H.R.; Gradle, C.G.; Narayanan, U.I.

    New Brunswick Laboratory (NBL) serves as the US Government`s Certifying Authority for nuclear reference materials and measurement calibration standards. In this role, NBL provides nuclear reference materials certified for chemical and/or isotopic compositions traceable to a nationally accepted, internationally compatible reference base. Emphasis is now changing as to the types of traceable nuclear reference materials needed as operations change within the Department of Energy (DOE) complex and at nuclear facilities around the world. Environmental and waste minimization issues, facilities and materials transitioning from processing to storage modes with corresponding changes in the types of measurements being performed, emphasis on requirementsmore » for characterization of waste materials, difficulties in transporting nuclear materials, and International factors, including International Atomic Energy Agency (IAEA) inspection of excess US nuclear materials, are all contributing influences. During these changing times, ft is critical that traceable reference materials be provided for calibration or validation of the performance of measurement systems. This paper will describe actions taken and planned to meet the changing reference material needs of the global nuclear community.« less

  2. Reference Materials and Subject Matter Knowledge Codes for Airman Knowledge Testing

    DOT National Transportation Integrated Search

    2004-06-08

    The listings of reference materials and subject matter knowledge codes have been : prepared by the Federal Aviation Administration (FAA) to establish specific : references for all knowledge standards. The listings contain reference materials : to be ...

  3. Outdoor characterization of radio frequency electromagnetic fields in a Spanish birth cohort.

    PubMed

    Calvente, I; Fernández, M F; Pérez-Lobato, R; Dávila-Arias, C; Ocón, O; Ramos, R; Ríos-Arrabal, S; Villalba-Moreno, J; Olea, N; Núñez, M I

    2015-04-01

    There is considerable public concern in many countries about the possible adverse effects of exposure to non-ionizing radiation electromagnetic fields, especially in vulnerable populations such as children. The aim of this study was to characterize environmental exposure profiles within the frequency range 100kHz-6GHz in the immediate surrounds of the dwellings of 123 families from the INMA-Granada birth cohort in Southern Spain, using spot measurements. The arithmetic mean root mean-square electric field (ERMS) and power density (SRMS) values were, respectively, 195.79mV/m (42.3% of data were above this mean) and 799.01µW/m(2) (30% of values were above this mean); median values were 148.80mV/m and 285.94µW/m(2), respectively. Exposure levels below the quantification limit were assigned a value of 0.01V/m. Incident field strength levels varied widely among different areas or towns/villages, demonstrating spatial variability in the distribution of exposure values related to the surface area population size and also among seasons. Although recorded values were well below International Commission for Non-Ionizing Radiation Protection reference levels, there is a particular need to characterize incident field strength levels in vulnerable populations (e.g., children) because of their chronic and ever-increasing exposure. The effects of incident field strength have not been fully elucidated; however, it may be appropriate to apply the precautionary principle in order to reduce exposure in susceptible groups. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. The importance of reference materials in doping-control analysis.

    PubMed

    Mackay, Lindsey G; Kazlauskas, Rymantas

    2011-08-01

    Currently a large range of pure substance reference materials are available for calibration of doping-control methods. These materials enable traceability to the International System of Units (SI) for the results generated by World Anti-Doping Agency (WADA)-accredited laboratories. Only a small number of prohibited substances have threshold limits for which quantification is highly important. For these analytes only the highest quality reference materials that are available should be used. Many prohibited substances have no threshold limits and reference materials provide essential identity confirmation. For these reference materials the correct identity is critical and the methods used to assess identity in these cases should be critically evaluated. There is still a lack of certified matrix reference materials to support many aspects of doping analysis. However, in key areas a range of urine matrix materials have been produced for substances with threshold limits, for example 19-norandrosterone and testosterone/epitestosterone (T/E) ratio. These matrix-certified reference materials (CRMs) are an excellent independent means of checking method recovery and bias and will typically be used in method validation and then regularly as quality-control checks. They can be particularly important in the analysis of samples close to threshold limits, in which measurement accuracy becomes critical. Some reference materials for isotope ratio mass spectrometry (IRMS) analysis are available and a matrix material certified for steroid delta values is currently under production. In other new areas, for example the Athlete Biological Passport, peptide hormone testing, designer steroids, and gene doping, reference material needs still need to be thoroughly assessed and prioritised.

  5. Bisphenol A polycarbonate as a reference material

    NASA Technical Reports Server (NTRS)

    Hilado, C. J.; Cumming, H. J.; Williams, J. B.

    1977-01-01

    Test methods require reference materials to standardize and maintain quality control. Various materials have been evaluated as possible reference materials, including a sample of bisphenol A polycarbonate without additives. Screening tests for relative toxicity under various experimental conditions were performed using male mice exposed to pyrolysis effluents over a 200-800 C temperature range. It was found that the bisphenol A polycarbonate served as a suitable reference material as it is available in large quantities, and does not significantly change with time.

  6. Using Analogs for Performance Testing of Humans in Spacesuits in Simulated Reduced Gravity

    NASA Technical Reports Server (NTRS)

    Norcross, Jason R.

    2013-01-01

    In general metabolic rates tend to be higher in NBL than in flight: a) Restraint method dependant; b) Significant differences between the NBL and flight for BRT and APFR (buoyancy effects). c) No significant difference between NBL and flight for free float and SRMS/SSRMS operations. The total metabolic energy expenditure for a given task and for the EVA as a whole are similar between NBL and flight: a) NBL metabolic rates are higher, but training EVAs are constrained to 5 1/2 hours. b) Flight metabolic rates are lower, but the EVAs are typically an hour or more longer in duration. NBL metabolic rates provide a useful operational tool for flight planning. Quantifying differences and similarities between training and flight improves knowledge for preparation of safe and efficient EVAs.

  7. Metabolic Expenditures During Extravehicular Activity: Spaceflight versus Ground-based Simulation

    NASA Technical Reports Server (NTRS)

    Klein, Jill; Conkin, Johnny; Gernhardt, Michael; Srinivasan, Ramachandra

    2008-01-01

    In general metabolic rates tend to be higher in NBL than in flight: a) Restraint method dependent; b) Significant differences between the NBL and flight for BRT and APFR (buoyancy effects); and c) No significant difference between NBL and flight for free float and SRMS/SSRMS operations. The total metabolic energy expenditure for a given task and for the EVA as a whole are similar between NBL and flight: a) NBL metabolic rates are higher, but training EVAs are constrained to 5 hours; and b) Flight metabolic rates are lower, but the EVAs are typically an hour or more longer in duration. NBL metabolic rates provide a useful operational tool for flight planning. Quantifying differences and similarities between training and flight improves knowledge for preparation of safe and efficient EVAs.

  8. First incremental buy for Increment 2 of the Space Transportation System (STS)

    NASA Technical Reports Server (NTRS)

    1989-01-01

    Thiokol manufactured and delivered 9 flight motors to KSC on schedule. All test flights were successful. All spent SRMs were recovered. Design, development, manufacture, and delivery of required transportation, handling, and checkout equipment to MSFC and to KSC were completed on schedule. All items of data required by DPD 400 were prepared and delivered as directed. In the system requirements and analysis area, the point of departure from Buy 1 to the operational phase was developed in significant detail with a complete set of transition documentation available. The documentation prepared during the Buy 1 program was maintained and updated where required. The following flight support activities should be continued through other production programs: as-built materials usage tracking on all flight hardware; mass properties reporting for all flight hardware until sample size is large enough to verify that the weight limit requirements were met; ballistic predictions and postflight performance assessments for all production flights; and recovered SRM hardware inspection and anomaly identification. In the safety, reliability, and quality assurance area, activities accomplished were assurance oriented in nature and specifically formulated to prevent problems and hardware failures. The flight program to date has adequately demonstrated the success of this assurance approach. The attention focused on details of design, analysis, manufacture, and inspection to assure the production of high-quality hardware has resulted in the absence of flight failures. The few anomalies which did occur were evaluated, design or manufacturing changes incorporated, and corrective actions taken to preclude recurrence.

  9. 40 CFR 1045.810 - What materials does this part reference?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Definitions and Other Reference Information § 1045.810 What materials does this part reference? Documents... material. Table 1 to this section lists material from the Society of Automotive Engineers that we have... the Society of Automotive Engineers, 400 Commonwealth Drive, Warrendale, PA 15096 or http://www.sae...

  10. Method and apparatus for assessing material properties of sheet-like materials

    DOEpatents

    Telschow, Kenneth L.; Deason, Vance A.

    2002-01-01

    Apparatus for producing an indication of a material property of a sheet-like material according to the present invention may comprise an excitation source for vibrating the sheet-like material to produce at least one traveling wave therein. A light source configured to produce an object wavefront and a reference wavefront directs the object wavefront toward the sheet-like material to produce a modulated object wavefront. A modulator operatively associated with the reference wavefront modulates the reference wavefront in synchronization with the traveling wave on the sheet-like material to produce a modulated reference wavefront. A sensing medium positioned to receive the modulated object wavefront and the modulated reference wavefront produces an image of the traveling wave in the sheet-like material, the image of the anti-symmetric traveling wave being related to a displacement amplitude of the anti-symmetric traveling wave over a two-dimensional area of the vibrating sheet-like material. A detector detects the image of the traveling wave in the sheet-like material.

  11. Reproducibility of polycarbonate reference material in toxicity evaluation

    NASA Technical Reports Server (NTRS)

    Hilado, C. J.; Huttlinger, P. A.

    1981-01-01

    A specific lot of bisphenol A polycarbonate has been used for almost four years as the reference material for the NASA-USF-PSC toxicity screening test method. The reproducibility of the test results over this period of time indicate that certain plastics may be more suitable reference materials than the more traditional cellulosic materials.

  12. Visual Resource Analysis for Solar Energy Zones in the San Luis Valley

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sullivan, Robert; Abplanalp, Jennifer M.; Zvolanek, Emily

    This report summarizes the results of a study conducted by Argonne National Laboratory’s (Argonne’s) Environmental Science Division for the U.S. Department of the Interior Bureau of Land Management (BLM). The study analyzed the regional effects of potential visual impacts of solar energy development on three BLM-designated solar energy zones (SEZs) in the San Luis Valley (SLV) in Colorado, and, based on the analysis, made recommendations for or against regional compensatory mitigation to compensate residents and other stakeholders for the potential visual impacts to the SEZs. The analysis was conducted as part of the solar regional mitigation strategy (SRMS) task conductedmore » by BLM Colorado with assistance from Argonne. Two separate analyses were performed. The first analysis, referred to as the VSA Analysis, analyzed the potential visual impacts of solar energy development in the SEZs on nearby visually sensitive areas (VSAs), and, based on the impact analyses, made recommendations for or against regional compensatory mitigation. VSAs are locations for which some type of visual sensitivity has been identified, either because the location is an area of high scenic value or because it is a location from which people view the surrounding landscape and attach some level of importance or sensitivity to what is seen from the location. The VSA analysis included both BLM-administered lands in Colorado and in the Taos FO in New Mexico. The second analysis, referred to as the SEZ Analysis, used BLM visual resource inventory (VRI) and other data on visual resources in the former Saguache and La Jara Field Offices (FOs), now contained within the San Luis Valley FO (SLFO), to determine whether the changes in scenic values that would result from the development of utility-scale solar energy facilities in the SEZs would affect the quality and quantity of valued scenic resources in the SLV region as a whole. If the regional effects were judged to be significant, regional compensatory mitigation was recommended. VRI data was not available for the Taos FO and it was not included in the SEZ analysis; the SEZ analysis includes BLM-administered lands in Colorado only.« less

  13. Nicotine, acetanilide and urea multi-level2H-,13C- and15N-abundance reference materials for continuous-flow isotope ratio mass spectrometry

    USGS Publications Warehouse

    Schimmelmann, A.; Albertino, A.; Sauer, P.E.; Qi, H.; Molinie, R.; Mesnard, F.

    2009-01-01

    Accurate determinations of stable isotope ratios require a calibration using at least two reference materials with different isotopic compositions to anchor the isotopic scale and compensate for differences in machine slope. Ideally, the S values of these reference materials should bracket the isotopic range of samples with unknown S values. While the practice of analyzing two isotopically distinct reference materials is common for water (VSMOW-SLAP) and carbonates (NBS 19 and L-SVEC), the lack of widely available organic reference materials with distinct isotopic composition has hindered the practice when analyzing organic materials by elemental analysis/isotope ratio mass spectrometry (EA-IRMS). At present only L-glutamic acids USGS40 and USGS41 satisfy these requirements for ??13C and ??13N, with the limitation that L-glutamic acid is not suitable for analysis by gas chromatography (GC). We describe the development and quality testing of (i) four nicotine laboratory reference materials for on-line (i.e. continuous flow) hydrogen reductive gas chromatography-isotope ratio mass-spectrometry (GC-IRMS), (ii) five nicotines for oxidative C, N gas chromatography-combustion-isotope ratio mass-spectrometry (GC-C-IRMS, or GC-IRMS), and (iii) also three acetanilide and three urea reference materials for on-line oxidative EA-IRMS for C and N. Isotopic off-line calibration against international stable isotope measurement standards at Indiana University adhered to the 'principle of identical treatment'. The new reference materials cover the following isotopic ranges: ??2Hnicotine -162 to -45%o, ??13Cnicotine -30.05 to +7.72%, ?? 15Nnicotine -6.03 to +33.62%; ??15N acetanilide +1-18 to +40.57%; ??13Curea -34.13 to +11.71%, ??15Nurea +0.26 to +40.61% (recommended ?? values refer to calibration with NBS 19, L-SVEC, IAEA-N-1, and IAEA-N-2). Nicotines fill a gap as the first organic nitrogen stable isotope reference materials for GC-IRMS that are available with different ??13N values. Comparative ??13C and ??15N on-line EA-IRMS data from 14 volunteering laboratories document the usefulness and reliability of acetanilides and ureas as EA-IRMS reference materials.

  14. Patient-assessed measures of health outcome in asthma: a comparison of four approaches.

    PubMed

    Garratt, A M; Hutchinson, A; Russell, I

    2000-06-01

    The study compares the psychometric properties of four different approaches to patient-assessed health outcomes in asthma, including the Asthma Quality of Life Questionnaire (AQLQ), Newcastle Asthma Symptoms Questionnaire (NASQ), SF-12 and EuroQol. The instruments were administered by means of a self-completed postal questionnaire to 394 patients recruited from general practices in the North East of England. Patients completed a follow-up questionnaire at 6 months. The levels of missing data were assessed and instrument scores compared using correlational analysis. Scores were related to self-reports of smoking behaviour, socioeconomic status and health transition. Responsiveness was assessed using standardized response means. Two hundred and thirty-five patients took part in the study giving a response rate of 59.6%. There was a relatively large amount of missing data for the individualized section of the AQLQ. Correlational analysis provided evidence of convergent validity between the specific instruments; the largest correlation was found between NASQ scores and the asthma symptoms scale of the AQLQ (r = 0.84). The NASQ was found to be the most powerful at discriminating between smokers and non-smokers. All four instruments were linearly related to self-reported asthma transition (P<0.05); the specific instruments having the strongest association. The specific instruments showed good levels of responsiveness with the NASQ producing a large SRM of 0.82. SRMs for the AQLQ were of a moderate to large size (0.32-0.77) and the SRMs for the SF-12 and EuroQol were of a small size. The two specific instruments are capable of greater levels of discrimination between groups of patients and are more responsive to changes in health than the generic SF-12 and EuroQol. The greater responsiveness of the NASQ is probably due to its focus being restricted to symptoms of asthma compared to the broader focus of the AQLQ domains. The NASQ has a strong relationship with the AQLQ and is a more practical instrument that is more acceptable to patients. However, the AQLQ does measure broader patient concerns. The SF-12 and EuroQol have greater potential to capture side-effects and have wider scope for application in economic evaluation.

  15. [Development of the certified reference material of mercury in lyophilized human urine].

    PubMed

    Zhao, Wei; Zhang, Fu-gang; DU, Hui-fang; Pan, Ya-juan; Yan, Hui-fang

    2011-02-01

    To develop the certified reference material of mercury in lyophilized human urine. Human urine samples from normal level mercury districts were filtered, homogenized, dispensed, lyophilized and radio-sterilized. Homogeneity test, stability inspection and certification were conducted using a atom fluorescence spectrophotometric method. The physical and chemical stability of the certified reference material were assessed for 18 months. The certified values are based on analysis made by three independent laboratories. The certified values are as follows: low level was (35.6 ± 2.1) µg/L, high level was (50.5 ± 3.0) µg/L. The certified reference material of mercury in lyophilized human urine in this research reached the national certified reference material requirements and could be used for the quality control.

  16. Devices for the Production of Reference Gas Mixtures.

    PubMed

    Fijało, Cyprian; Dymerski, Tomasz; Gębicki, Jacek; Namieśnik, Jacek

    2016-09-02

    For many years there has been growing demand for gaseous reference materials, which is connected with development in many fields of science and technology. As a result, new methodological and instrumental solutions appear that can be used for this purpose. Appropriate quality assurance/quality control (QA/QC) must be used to make sure that measurement data are a reliable source of information. Reference materials are a significant element of such systems. In the case of gas samples, such materials are generally called reference gas mixtures. This article presents the application and classification of reference gas mixtures, which are a specific type of reference materials, and the methods for obtaining them are described. Construction solutions of devices for the production of reference gas mixtures are detailed, and a description of a prototype device for dynamic production of reference gas mixtures containing aroma compounds is presented.

  17. Some possible reference materials for fire toxicity tests

    NASA Technical Reports Server (NTRS)

    Hilado, C. J.; Solis, A. N.

    1977-01-01

    Suitable reference materials need to be selected in order to standardize any test method. The evaluation of cotton, polyethylene, polyether sulfone, polycarbonate, polystyrene, and polyurethane flexible and rigid foams as possible reference materials for the University of San Francisco/NASA toxicity screening test method is discussed.

  18. Probabilistic failure assessment with application to solid rocket motors

    NASA Technical Reports Server (NTRS)

    Jan, Darrell L.; Davidson, Barry D.; Moore, Nicholas R.

    1990-01-01

    A quantitative methodology is being developed for assessment of risk of failure of solid rocket motors. This probabilistic methodology employs best available engineering models and available information in a stochastic framework. The framework accounts for incomplete knowledge of governing parameters, intrinsic variability, and failure model specification error. Earlier case studies have been conducted on several failure modes of the Space Shuttle Main Engine. Work in progress on application of this probabilistic approach to large solid rocket boosters such as the Advanced Solid Rocket Motor for the Space Shuttle is described. Failure due to debonding has been selected as the first case study for large solid rocket motors (SRMs) since it accounts for a significant number of historical SRM failures. Impact of incomplete knowledge of governing parameters and failure model specification errors is expected to be important.

  19. 10 CFR 431.105 - Materials incorporated by reference.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Storage Tanks Test Procedures § 431.105 Materials incorporated by reference. (a) The Department... Water Supply Boilers, and Unfired Hot Water Storage Tanks,” Docket No. EE-RM/TP-99-480, Forrestal... 10 Energy 3 2012-01-01 2012-01-01 false Materials incorporated by reference. 431.105 Section 431...

  20. NBS/EPA (NATIONAL BUREAU OF STANDARDS/ENVIRONMENTAL PROTECTION AGENCY) CERTIFIED REFERENCE MATERIAL PERFORMANCE AUDIT PROGRAM: STATUS REPORT 2

    EPA Science Inventory

    A traceability procedure has been established which allows specialty gas producers to prepare gaseous pollutant Certified Reference Materials (CRM's). The accuracy, stability and homogeneity of the CRM's approach those of NBS Standard Reference Materials (SRM's). As of October 19...

  1. Nicotine, acetanilide and urea multi-level 2H-, 13C- and 15N-abundance reference materials for continuous-flow isotope ratio mass spectrometry.

    PubMed

    Schimmelmann, Arndt; Albertino, Andrea; Sauer, Peter E; Qi, Haiping; Molinie, Roland; Mesnard, François

    2009-11-01

    Accurate determinations of stable isotope ratios require a calibration using at least two reference materials with different isotopic compositions to anchor the isotopic scale and compensate for differences in machine slope. Ideally, the delta values of these reference materials should bracket the isotopic range of samples with unknown delta values. While the practice of analyzing two isotopically distinct reference materials is common for water (VSMOW-SLAP) and carbonates (NBS 19 and L-SVEC), the lack of widely available organic reference materials with distinct isotopic composition has hindered the practice when analyzing organic materials by elemental analysis/isotope ratio mass spectrometry (EA-IRMS). At present only L-glutamic acids USGS40 and USGS41 satisfy these requirements for delta13C and delta15N, with the limitation that L-glutamic acid is not suitable for analysis by gas chromatography (GC). We describe the development and quality testing of (i) four nicotine laboratory reference materials for on-line (i.e. continuous flow) hydrogen reductive gas chromatography-isotope ratio mass-spectrometry (GC-IRMS), (ii) five nicotines for oxidative C, N gas chromatography-combustion-isotope ratio mass-spectrometry (GC-C-IRMS, or GC-IRMS), and (iii) also three acetanilide and three urea reference materials for on-line oxidative EA-IRMS for C and N. Isotopic off-line calibration against international stable isotope measurement standards at Indiana University adhered to the 'principle of identical treatment'. The new reference materials cover the following isotopic ranges: delta2H(nicotine) -162 to -45 per thousand, delta13C(nicotine) -30.05 to +7.72 per thousand, delta15N(nicotine) -6.03 to +33.62 per thousand; delta15N(acetanilide) +1.18 to +40.57 per thousand; delta13C(urea) -34.13 to +11.71 per thousand, delta15N(urea) +0.26 to +40.61 per thousand (recommended delta values refer to calibration with NBS 19, L-SVEC, IAEA-N-1, and IAEA-N-2). Nicotines fill a gap as the first organic nitrogen stable isotope reference materials for GC-IRMS that are available with different delta15N values. Comparative delta13C and delta15N on-line EA-IRMS data from 14 volunteering laboratories document the usefulness and reliability of acetanilides and ureas as EA-IRMS reference materials. Copyright 2009 John Wiley & Sons, Ltd.

  2. Baseline Assessment of 25-Hydroxyvitamin D Reference Material and Proficiency Testing/External Quality Assurance Material Commutability: A Vitamin D Standardization Program Study.

    PubMed

    Phinney, Karen W; Sempos, Christopher T; Tai, Susan S-C; Camara, Johanna E; Wise, Stephen A; Eckfeldt, John H; Hoofnagle, Andrew N; Carter, Graham D; Jones, Julia; Myers, Gary L; Durazo-Arvizu, Ramon; Miller, W Greg; Bachmann, Lorin M; Young, Ian S; Pettit, Juanita; Caldwell, Grahame; Liu, Andrew; Brooks, Stephen P J; Sarafin, Kurtis; Thamm, Michael; Mensink, Gert B M; Busch, Markus; Rabenberg, Martina; Cashman, Kevin D; Kiely, Mairead; Galvin, Karen; Zhang, Joy Y; Kinsella, Michael; Oh, Kyungwon; Lee, Sun-Wha; Jung, Chae L; Cox, Lorna; Goldberg, Gail; Guberg, Kate; Meadows, Sarah; Prentice, Ann; Tian, Lu; Brannon, Patsy M; Lucas, Robyn M; Crump, Peter M; Cavalier, Etienne; Merkel, Joyce; Betz, Joseph M

    2017-09-01

    The Vitamin D Standardization Program (VDSP) coordinated a study in 2012 to assess the commutability of reference materials and proficiency testing/external quality assurance materials for total 25-hydroxyvitamin D [25(OH)D] in human serum, the primary indicator of vitamin D status. A set of 50 single-donor serum samples as well as 17 reference and proficiency testing/external quality assessment materials were analyzed by participating laboratories that used either immunoassay or LC-MS methods for total 25(OH)D. The commutability test materials included National Institute of Standards and Technology Standard Reference Material 972a Vitamin D Metabolites in Human Serum as well as materials from the College of American Pathologists and the Vitamin D External Quality Assessment Scheme. Study protocols and data analysis procedures were in accordance with Clinical and Laboratory Standards Institute guidelines. The majority of the test materials were found to be commutable with the methods used in this commutability study. These results provide guidance for laboratories needing to choose appropriate reference materials and select proficiency or external quality assessment programs and will serve as a foundation for additional VDSP studies.

  3. Evaluation of droplet digital PCR for characterizing plasmid reference material used for quantifying ammonia oxidizers and denitrifiers.

    PubMed

    Dong, Lianhua; Meng, Ying; Wang, Jing; Liu, Yingying

    2014-02-01

    DNA reference materials of certified value have a critical function in many analytical processes of DNA measurement. Quantification of amoA genes in ammonia oxidizing bacteria (AOB) and archaea (AOA), and of nirS and nosZ genes in the denitrifiers is very important for determining their distribution and abundance in the natural environment. A plasmid reference material containing nirS, nosZ, amoA-AOB, and amoA-AOA is developed to provide a DNA standard with copy number concentration for ensuring comparability and reliability of quantification of these genes. Droplet digital PCR (ddPCR) was evaluated for characterization of the plasmid reference material. The result revealed that restriction endonuclease digestion of plasmids can improve amplification efficiency and minimize the measurement bias of ddPCR. Compared with the conformation of the plasmid, the size of the DNA fragment containing the target sequence and the location of the restriction site relative to the target sequence are not significant factors affecting plasmid quantification by ddPCR. Liquid chromatography-isotope dilution mass spectrometry (LC-IDMS) was used to provide independent data for quantifying the plasmid reference material. The copy number concentration of the digested plasmid determined by ddPCR agreed well with that determined by LC-IDMS, improving both the accuracy and reliability of the plasmid reference material. The reference value, with its expanded uncertainty (k = 2), of the plasmid reference material was determined to be (5.19 ± 0.41) × 10(9) copies μL(-1) by averaging the results of two independent measurements. Consideration of the factors revealed in this study can improve the reliability and accuracy of ddPCR; thus, this method has the potential to accurately quantify DNA reference materials.

  4. 49 CFR 572.30 - Incorporated materials.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 7 2011-10-01 2011-10-01 false Incorporated materials. 572.30 Section 572.30....30 Incorporated materials. (a) The drawings and specifications referred to in this regulation that... Federal Register has approved the materials incorporated by reference. For materials subject to change...

  5. 49 CFR 572.30 - Incorporated materials.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 7 2010-10-01 2010-10-01 false Incorporated materials. 572.30 Section 572.30....30 Incorporated materials. (a) The drawings and specifications referred to in this regulation that... Federal Register has approved the materials incorporated by reference. For materials subject to change...

  6. 49 CFR 572.30 - Incorporated materials.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 7 2012-10-01 2012-10-01 false Incorporated materials. 572.30 Section 572.30....30 Incorporated materials. (a) The drawings and specifications referred to in this regulation that... Federal Register has approved the materials incorporated by reference. For materials subject to change...

  7. 49 CFR 572.30 - Incorporated materials.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 7 2013-10-01 2013-10-01 false Incorporated materials. 572.30 Section 572.30....30 Incorporated materials. (a) The drawings and specifications referred to in this regulation that... Federal Register has approved the materials incorporated by reference. For materials subject to change...

  8. [Development and application of reference materials containing mixed degradation products of amoxicillin and ampicillin].

    PubMed

    Li, Wei; Zhang, Wei-Qing; Li, Xiang; Hu, Chang-Qin

    2014-09-01

    Reference materials containing mixed degradation products of amoxicillin and ampicillin were developed after optimization of preparation processes. The target impurities were obtained by controlled stress testing, and each major component was identified with HPLC-MS and compared with single traceable reference standard each. The developed reference materials were applied to system suitability test for verifying HPLC system performed in accordance with set forth in China Pharmacopeia and identification of major impurities in samples based on retention and spectra information, which have advantages over the methods put forth in foreign pharmacopoeias. The development and application of the reference materials offer an effective way for rapid identification of impurities in chromatograms, and provide references for analyzing source of impurities and evaluation of drug quality.

  9. Certified reference materials and reference methods for nuclear safeguards and security.

    PubMed

    Jakopič, R; Sturm, M; Kraiem, M; Richter, S; Aregbe, Y

    2013-11-01

    Confidence in comparability and reliability of measurement results in nuclear material and environmental sample analysis are established via certified reference materials (CRMs), reference measurements, and inter-laboratory comparisons (ILCs). Increased needs for quality control tools in proliferation resistance, environmental sample analysis, development of measurement capabilities over the years and progress in modern analytical techniques are the main reasons for the development of new reference materials and reference methods for nuclear safeguards and security. The Institute for Reference Materials and Measurements (IRMM) prepares and certifices large quantities of the so-called "large-sized dried" (LSD) spikes for accurate measurement of the uranium and plutonium content in dissolved nuclear fuel solutions by isotope dilution mass spectrometry (IDMS) and also develops particle reference materials applied for the detection of nuclear signatures in environmental samples. IRMM is currently replacing some of its exhausted stocks of CRMs with new ones whose specifications are up-to-date and tailored for the demands of modern analytical techniques. Some of the existing materials will be re-measured to improve the uncertainties associated with their certified values, and to enable laboratories to reduce their combined measurement uncertainty. Safeguards involve the quantitative verification by independent measurements so that no nuclear material is diverted from its intended peaceful use. Safeguards authorities pay particular attention to plutonium and the uranium isotope (235)U, indicating the so-called 'enrichment', in nuclear material and in environmental samples. In addition to the verification of the major ratios, n((235)U)/n((238)U) and n((240)Pu)/n((239)Pu), the minor ratios of the less abundant uranium and plutonium isotopes contain valuable information about the origin and the 'history' of material used for commercial or possibly clandestine purposes, and have therefore reached high level of attention for safeguards authorities. Furthermore, IRMM initiated and coordinated the development of a Modified Total Evaporation (MTE) technique for accurate abundance ratio measurements of the "minor" isotope-amount ratios of uranium and plutonium in nuclear material and, in combination with a multi-dynamic measurement technique and filament carburization, in environmental samples. Currently IRMM is engaged in a study on the development of plutonium reference materials for "age dating", i.e. determination of the time elapsed since the last separation of plutonium from its daughter nuclides. The decay of a radioactive parent isotope and the build-up of a corresponding amount of daughter nuclide serve as chronometer to calculate the age of a nuclear material. There are no such certified reference materials available yet. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. History of reference materials for food and nutrition metrology: As represented in the series of BERM Symposia

    USDA-ARS?s Scientific Manuscript database

    Establishment of a metrology-based measurement system requires the solid foundation of traceability of measurements to available, appropriate certified reference materials (CRM). In the early 1970s the first “biological” Reference Material (RM) of Bowens Kale, Orchard Leaves, and Bovine Liver from ...

  11. 40 CFR 89.6 - Reference materials.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... set forth the material that has been incorporated by reference in this part. (1) ASTM material. The... 19428-2959. Document number and name 40 CFR part 89 reference ASTM D86-97: “Standard Test Method for Distillation of Petroleum Products at Atmospheric Pressure” Appendix A to Subpart D. ASTM D93-97: “Standard...

  12. National Nutrition Education Clearing House Reference List, Secondary Teaching Materials and Teacher References.

    ERIC Educational Resources Information Center

    National Nutrition Education Clearing House, Berkeley, CA.

    A reference list of teaching materials and teacher guides in the field of nutrition is compiled in this pamphlet. Primary emphasis is on resources for secondary grades. The section on teaching materials includes books, pamphlets, leaflets, posters, charts, transparencies, ditto masters, kits, games, films, filmstrips, records, TV videotapes, and…

  13. Preparation of an in-house reference material containing fumonisins in Thai rice and matrix extension of the analytical method for Japanese rice.

    PubMed

    Awaludin, Norhafniza; Nagata, Reiko; Kawasaki, Tomomi; Kushiro, Masayo

    2009-12-01

    Mycotoxin contamination in rice is less reported, compared to that in wheat or maize, however, some Fusarium fungi occasionally infect rice in the paddy field. Fumonisins are mycotoxins mainly produced by Fusarium verticillioides, which often ruins maize. Rice adherent fungus Gibberella fujikuroi is taxonomically near to F. verticillioides, and there are sporadic reports of fumonisin contamination in rice from Asia, Europe and the United States. Therefore, there exists the potential risk of fumonisin contamination in rice as well as the need for the validated analytical method for fumonisins in rice. Although both natural and spiked reference materials are available for some Fusarium mycotoxins in matrices of wheat and maize, there are no reference materials for Fusarium mycotoxins in rice. In this study, we have developed a method for the preparation of a reference material containing fumonisins in Thai rice. A ShakeMaster grinding machine was used for the preparation of a mixed material of blank Thai rice and F. verticillioides-infected Thai rice. The homogeneity of the mixed material was confirmed by one-way analysis of variance, which led this material to serve as an in-house reference material. Using this reference material, several procedures to extract fumonisins from Thai rice were compared. Accordingly, we proved the applicability of an effective extraction procedure for the determination of fumonisins in Japanese rice.

  14. Preparation of an In-House Reference Material Containing Fumonisins in Thai Rice and Matrix Extension of the Analytical Method for Japanese Rice

    PubMed Central

    Awaludin, Norhafniza; Nagata, Reiko; Kawasaki, Tomomi; Kushiro, Masayo

    2009-01-01

    Mycotoxin contamination in rice is less reported, compared to that in wheat or maize, however, some Fusarium fungi occasionally infect rice in the paddy field. Fumonisins are mycotoxins mainly produced by Fusarium verticillioides, which often ruins maize. Rice adherent fungus Gibberella fujikuroi is taxonomically near to F. verticillioides, and there are sporadic reports of fumonisin contamination in rice from Asia, Europe and the United States. Therefore, there exists the potential risk of fumonisin contamination in rice as well as the need for the validated analytical method for fumonisins in rice. Although both natural and spiked reference materials are available for some Fusarium mycotoxins in matrices of wheat and maize, there are no reference materials for Fusarium mycotoxins in rice. In this study, we have developed a method for the preparation of a reference material containing fumonisins in Thai rice. A ShakeMaster grinding machine was used for the preparation of a mixed material of blank Thai rice and F. verticillioides-infected Thai rice. The homogeneity of the mixed material was confirmed by one-way analysis of variance, which led this material to serve as an in-house reference material. Using this reference material, several procedures to extract fumonisins from Thai rice were compared. Accordingly, we proved the applicability of an effective extraction procedure for the determination of fumonisins in Japanese rice. PMID:22069540

  15. 49 CFR 193.2013 - Incorporation by reference.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY LIQUEFIED NATURAL... incorporated materials are available for inspection in the Pipeline and Hazardous Materials Safety... referenced material 49 CFR Reference A. American Gas Association (AGA): (1) “Purging Principles and Practices...

  16. A new thorium-229 reference material

    DOE PAGES

    Essex, Richard M.; Mann, Jaqueline L.; Williams, Ross W.; ...

    2017-07-27

    A new reference material was characterized for 229Th molality and thorium isotope amount ratios. This reference material is intended for use in nuclear forensic analyses as an isotope dilution mass spectrometry spike. The reference material value and expanded uncertainty (k = 2) for the 229Th molality is (1.1498 ± 0.0016)×10 -10 mol g -1 solution. The value and expanded uncertainty (k = 2) for the n( 230Th)/n( 229Th) ratio is (5.18 ± 0.26)×10 -5 and the n( 232Th)/n( 229Th) ratio is (3.815 ± 0.092)×10 -4.

  17. A new thorium-229 reference material

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Essex, Richard M.; Mann, Jaqueline L.; Williams, Ross W.

    A new reference material was characterized for 229Th molality and thorium isotope amount ratios. This reference material is intended for use in nuclear forensic analyses as an isotope dilution mass spectrometry spike. The reference material value and expanded uncertainty (k = 2) for the 229Th molality is (1.1498 ± 0.0016)×10 -10 mol g -1 solution. The value and expanded uncertainty (k = 2) for the n( 230Th)/n( 229Th) ratio is (5.18 ± 0.26)×10 -5 and the n( 232Th)/n( 229Th) ratio is (3.815 ± 0.092)×10 -4.

  18. 15 CFR 200.104 - Standard reference materials.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... the NIST National Measurement Laboratory administers a program to provide many types of well... be readily referred to a common base. NIST SP 260 is a catalog of Standard Reference Materials available from NIST. ...

  19. 15 CFR 200.104 - Standard reference materials.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... the NIST National Measurement Laboratory administers a program to provide many types of well... be readily referred to a common base. NIST SP 260 is a catalog of Standard Reference Materials available from NIST. ...

  20. 15 CFR 200.104 - Standard reference materials.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... the NIST National Measurement Laboratory administers a program to provide many types of well... be readily referred to a common base. NIST SP 260 is a catalog of Standard Reference Materials available from NIST. ...

  1. 15 CFR 200.104 - Standard reference materials.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... the NIST National Measurement Laboratory administers a program to provide many types of well... be readily referred to a common base. NIST SP 260 is a catalog of Standard Reference Materials available from NIST. ...

  2. 15 CFR 200.104 - Standard reference materials.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... the NIST National Measurement Laboratory administers a program to provide many types of well... be readily referred to a common base. NIST SP 260 is a catalog of Standard Reference Materials available from NIST. ...

  3. Requirements for the Development of Bacillus Anthracis Spore Reference Materials Used to Test Detection Systems

    PubMed Central

    Almeida, Jamie L.; Wang, Lili; Morrow, Jayne B.; Cole, Kenneth D.

    2006-01-01

    Bacillus anthracis spores have been used as biological weapons and the possibility of their further use requires surveillance systems that can accurately and reliably detect their presence in the environment. These systems must collect samples from a variety of matrices, process the samples, and detect the spores. The processing of the sample may include removal of inhibitors, concentration of the target, and extraction of the target in a form suitable for detection. Suitable reference materials will allow the testing of each of these steps to determine the sensitivity and specificity of the detection systems. The development of uniform and well-characterized reference materials will allow the comparison of different devices and technologies as well as assure the continued performance of detection systems. This paper discusses the special requirements of reference materials for Bacillus anthracis spores that could be used for testing detection systems. The detection of Bacillus anthracis spores is based on recognition of specific characteristics (markers) on either the spore surface or in the nucleic acids (DNA). We have reviewed the specific markers and their relevance to characterization of reference materials. We have also included the approach for the characterization of candidate reference materials that we are developing at the NIST laboratories. Additional applications of spore reference materials would include testing sporicidal treatments, techniques for sampling the environment, and remediation of spore-contaminated environments. PMID:27274929

  4. Reference Materials: Significance, General Requirements, and Demand.

    PubMed

    Kiełbasa, Anna; Gadzała-Kopciuch, Renata; Buszewski, Bogusław

    2016-05-03

    Reference materials play an important part in the quality control of measurements. Rapid development of such new scientific disciplines as proteomics, metabolomics, and genomics also necessitates development of new reference materials. This is a great challenge due to the complexity of the production of new reference materials and difficulties associated with achieving their homogeneity and stability. CRMs of tissue are of particular importance. They can be counted among the matrices that are most complex and time consuming in preparation. Tissue is the place of transformation and accumulation of many substances (e.g., metabolites, which are intermediate or end products resulting from metabolic processes). Trace amounts of many substances in tissues must be determined with adequate precision and accuracy. To meet the needs stemming from research and from problems and challenges faced by chemists, analysts, and toxicologists, the number of certified reference materials should be continuously increased.

  5. High-precision isotopic characterization of USGS reference materials by TIMS and MC-ICP-MS

    NASA Astrophysics Data System (ADS)

    Weis, Dominique; Kieffer, Bruno; Maerschalk, Claude; Barling, Jane; de Jong, Jeroen; Williams, Gwen A.; Hanano, Diane; Pretorius, Wilma; Mattielli, Nadine; Scoates, James S.; Goolaerts, Arnaud; Friedman, Richard M.; Mahoney, J. Brian

    2006-08-01

    The Pacific Centre for Isotopic and Geochemical Research (PCIGR) at the University of British Columbia has undertaken a systematic analysis of the isotopic (Sr, Nd, and Pb) compositions and concentrations of a broad compositional range of U.S. Geological Survey (USGS) reference materials, including basalt (BCR-1, 2; BHVO-1, 2), andesite (AGV-1, 2), rhyolite (RGM-1, 2), syenite (STM-1, 2), granodiorite (GSP-2), and granite (G-2, 3). USGS rock reference materials are geochemically well characterized, but there is neither a systematic methodology nor a database for radiogenic isotopic compositions, even for the widely used BCR-1. This investigation represents the first comprehensive, systematic analysis of the isotopic composition and concentration of USGS reference materials and provides an important database for the isotopic community. In addition, the range of equipment at the PCIGR, including a Nu Instruments Plasma MC-ICP-MS, a Thermo Finnigan Triton TIMS, and a Thermo Finnigan Element2 HR-ICP-MS, permits an assessment and comparison of the precision and accuracy of isotopic analyses determined by both the TIMS and MC-ICP-MS methods (e.g., Nd isotopic compositions). For each of the reference materials, 5 to 10 complete replicate analyses provide coherent isotopic results, all with external precision below 30 ppm (2 SD) for Sr and Nd isotopic compositions (27 and 24 ppm for TIMS and MC-ICP-MS, respectively). Our results also show that the first- and second-generation USGS reference materials have homogeneous Sr and Nd isotopic compositions. Nd isotopic compositions by MC-ICP-MS and TIMS agree to within 15 ppm for all reference materials. Interlaboratory MC-ICP-MS comparisons show excellent agreement for Pb isotopic compositions; however, the reproducibility is not as good as for Sr and Nd. A careful, sequential leaching experiment of three first- and second-generation reference materials (BCR, BHVO, AGV) indicates that the heterogeneity in Pb isotopic compositions, and concentrations, could be directly related to contamination by the steel (mortar/pestle) used to process the materials. Contamination also accounts for the high concentrations of certain other trace elements (e.g., Li, Mo, Cd, Sn, Sb, W) in various USGS reference materials.

  6. [Report of the NEDO project "Research and development to promote the creation and utilization of an intellectual infrastructure: development of reference materials for laboratory medicine" "Development of pure substance-type certified reference materials"].

    PubMed

    Takatsu, Akiko

    2009-06-01

    There is an increasing demand to establish a metrological traceability system for in vitro diagnostics and medical devices. Pure substance-type reference materials are playing key roles in metrological traceability, because they form the basis for many traceability chains in chemistry. The National Metrology Institute of Japan (NMIJ), in the National Institute of Advanced Industrial Science and Technology (AIST), has been developing purity-certified reference materials (CRMs) in this field, such as cholesterol, creatinine, and urea. In the New Energy and Industrial Technology Development Organization (NEDO) project, entitled: "Research and Development to Promote the Creation and Utilization of an Intellectual Infrastructure: Development of Reference Materials for Laboratory Medicine", several pure substance-type CRMs were developed. For a pure protein solution CRM, amino acid analysis and nitrogen determination were chosen as the certification methods. The development and certification processes for the C-reactive protein (CRP) solution CRM were completed, with the recombinant human CRP solution as a candidate material. This CRP solution CRM is now available as NMIJ CRM. For cortisol CRM, a purified candidate material and highly pure primary reference material were prepared. Each impure compound in the materials was identified and quantified. The pure cortisol CRM will be available in 2009. These two CRMs provide a traceability link between routine clinical methods and the SI unit.

  7. DOE research and development report. Progress report, October 1980-September 1981

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bingham, Carleton D.

    The DOE New Brunswick Laboratory (NBL) is the US Government's Nuclear Materials Standards and Measurement Laboratory. NBL is assigned the mission to provide and maintain, as an essential part of federal statutory responsibilities related to national and international safeguards of nuclear materials for USA defense and energy programs, an ongoing capability for: the development, preparation, certification, and distribution of reference materials for the calibration and standardization of nuclear materials measurements; the development, improvement, and evaluation of nuclear materials measurement technology; the assessment and evaluation of the practice and application of nuclear materials measurement technology; expert and reliable specialized nuclear materialsmore » measurement services for the government; and technology exchange and training in nuclear materials measurement and standards. Progress reports for this fiscal year are presented under the following sections: (1) development or evaluation of measurement technology (elemental assay of uranium plutonium; isotope composition); (2) standards and reference materials (NBL standards and reference materials; NBS reference materials); and (3) evaluation programs (safeguards analytical laboratory evaluation; general analytical evaluation program; other evaluation programs).« less

  8. Investigating adsorption/desorption of carbon dioxide in aluminum compressed gas cylinders.

    PubMed

    Miller, Walter R; Rhoderick, George C; Guenther, Franklin R

    2015-02-03

    Between June 2010 and June 2011, the National Institute of Standards and Technology (NIST) gravimetrically prepared a suite of 20 carbon dioxide (CO2) in air primary standard mixtures (PSMs). Ambient mole fraction levels were obtained through six levels of dilution beginning with pure (99.999%) CO2. The sixth level covered the ambient range from 355 to 404 μmol/mol. This level will be used to certify cylinder mixtures of compressed dry whole air from both the northern and southern hemispheres as NIST standard reference materials (SRMs). The first five levels of PSMs were verified against existing PSMs in a balance of air or nitrogen with excellent agreement observed (the average percent difference between the calculated and analyzed values was 0.002%). After the preparation of a new suite of PSMs at ambient level, they were compared to an existing suite of PSMs. It was observed that the analyzed concentration of the new PSMs was less than the calculated gravimetric concentration by as much as 0.3% relative. The existing PSMs had been used in a Consultative Committee for Amount of Substance-Metrology in Chemistry Key Comparison (K-52) in which there was excellent agreement (the NIST-analyzed value was -0.09% different from the calculated value, while the average of the difference for all 18 participants was -0.10%) with those of other National Metrology Institutes and World Meteorological Organization designated laboratories. In order to determine the magnitude of these losses at the ambient level, a series of "daughter/mother" tests were initiated and conducted in which the gas mixture containing CO2 from a "mother" cylinder was transferred into an evacuated "daughter" cylinder. These cylinder pairs were then compared using cavity ring-down spectroscopy under high reproducibility conditions (the average percent relative standard deviation of sample response was 0.02). A ratio of the daughter instrument response to the mother response was calculated, with the resultant deviation from unity being a measure of the CO2 loss or gain. Cylinders from three specialty gas vendors were tested to find the appropriate cylinder in which to prepare the new PSMs. All cylinders tested showed a loss of CO2, presumably to the walls of the cylinder. The vendor cylinders exhibiting the least loss of CO2 were then purchased to be used to gravimetrically prepare the PSMs, adjusting the calculated mole fraction for the loss bias and an uncertainty calculated from this work.

  9. delta 15N and non-carbonate delta 13C values for two petroleum source rock reference materials and a marine sediment reference material

    USGS Publications Warehouse

    Dennen, Kristin O.; Johnson, Craig A.; Otter, Marshall L.; Silva, Steven R.; Wandless, Gregory A.

    2006-01-01

    Samples of United States Geological Survey (USGS) Certified Reference Materials USGS Devonian Ohio Shale (SDO-1), and USGS Eocene Green River Shale (SGR-1), and National Research Council Canada (NRCC) Certified Marine Sediment Reference Material (PACS-2), were sent for analysis to four separate analytical laboratories as blind controls for organic rich sedimentary rock samples being analyzed from the Red Dog mine area in Alaska. The samples were analyzed for stable isotopes of carbon (delta13Cncc) and nitrogen (delta15N), percent non-carbonate carbon (Wt % Cncc) and percent nitrogen (Wt % N). SDO-1, collected from the Huron Member of the Ohio Shale, near Morehead, Kentucky, and SGR-1, collected from the Mahogany zone of the Green River Formation are petroleum source rocks used as reference materials for chemical analyses of sedimentary rocks. PACS-2 is modern marine sediment collected from the Esquimalt, British Columbia harbor. The results presented in this study are, with the exceptions noted below, the first published for these reference materials. There are published information values for the elemental concentrations of 'organic' carbon (Wt % Corg measured range is 8.98 - 10.4) and nitrogen (Wt % Ntot 0.347 with SD 0.043) only for SDO-1. The suggested values presented here should be considered 'information values' as defined by the NRCC Institute for National Measurement Reference Materials and should be useful for the analysis of 13C, 15N, C and N in organic material in sedimentary rocks.

  10. Biscayne aquifer drinking water (USGS45): a new isotopic reference material for δ2H and δ18O measurements of water

    USGS Publications Warehouse

    Lorenz, Jennifer M.; Tarbox, Lauren V.; Buck, Bryan; Qi, Haiping; Coplen, Tyler B.

    2014-01-01

    RATIONALE As a result of the scarcity of isotopic reference waters for daily use, a new secondary isotopic reference material for international distribution has been prepared from drinking water collected from the Biscayne aquifer in Ft. Lauderdale, Florida. METHODS This isotopic reference water was filtered, homogenized, loaded into glass ampoules, sealed with a torch, autoclaved to eliminate biological activity, and measured by dual-inlet isotope-ratio mass spectrometry. This reference material is available by the case of 144 glass ampoules containing either 4 mL or 5 mL of water in each ampoule. RESULTS The δ2H and δ18O values of this reference material are –10.3 ± 0.4 ‰ and –2.238 ± 0.011 ‰, respectively, relative to VSMOW, on scales normalized such that the δ2H and δ18O values of SLAP reference water are, respectively, –428 and –55.5 ‰. Each uncertainty is an estimated expanded uncertainty (U = 2uc) about the reference value that provides an interval that has about a 95 % probability of encompassing the true value. CONCLUSIONS This isotopic reference material, designated as USGS45, is intended as one of two isotopic reference waters for daily normalization of stable hydrogen and oxygen isotopic analysis of water with an isotope-ratio mass spectrometer or a laser absorption spectrometer. 

  11. The 260: The Largest Solid Rocket Motor Ever Tested

    NASA Technical Reports Server (NTRS)

    Crimmins, P.; Cousineau, M.; Rogers, C.; Shell, V.

    1999-01-01

    Aerojet in the mid 1960s, under contract to NASA, built and static hot fire tested the largest solid rocket motor (SRM) in history for the purpose of demonstrating the feasibility of utilizing large SRMs for space exploration. This program successfully fabricated two high strength steel chambers, loaded each with approximately 1,68 million pounds of propellant, and static test fired these giants with their nozzles up from an underground silo located adjacent to the Florida everglades. Maximum thrust and total impulse in excess of 5,000,000 lbf and 3,470,000,000 lbf-sec were achieved. Flames from the second firing, conducted at night, were seen over eighty miles away. For comparative purposes: the thrust developed was nearly 100 times that of a Minuteman III second stage and the 260 in.-dia cross-section was over 3 times that of the Space Shuttle SRM.

  12. Pressure oscillations and instability of working processes in the combustion chambers of solid rocket motors

    NASA Astrophysics Data System (ADS)

    Emelyanov, V. N.; Teterina, I. V.; Volkov, K. N.; Garkushev, A. U.

    2017-06-01

    Metal particles are widely used in space engineering to increase specific impulse and to supress acoustic instability of intra-champber processes. A numerical analysis of the internal injection-driven turbulent gas-particle flows is performed to improve the current understanding and modeling capabilities of the complex flow characteristics in the combustion chambers of solid rocket motors (SRMs) in presence of forced pressure oscillations. The two-phase flow is simulated with a combined Eulerian-Lagrangian approach. The Reynolds-averaged Navier-Stokes equations and transport equations of k - ε model are solved numerically for the gas. The particulate phase is simulated through a Lagrangian deterministic and stochastic tracking models to provide particle trajectories and particle concentration. The results obtained highlight the crucial significance of the particle dispersion in turbulent flowfield and high potential of statistical methods. Strong coupling between acoustic oscillations, vortical motion, turbulent fluctuations and particle dynamics is observed.

  13. KSC-2014-2127

    NASA Image and Video Library

    2014-04-11

    VANDENBERG AIR FORCE BASE, Calif. – A solid rocket motor, or SRM, for NASA's Orbiting Carbon Observatory-2 mission, or OCO-2, arrives at the mobile service tower at Space Launch Complex 2 on Vandenberg Air Force Base in California. Operations are underway to attach the Delta II rocket's three SRMs, known as graphite epoxy motors, to the rocket's first stage. OCO-2 is scheduled to launch into a polar Earth orbit aboard a United Launch Alliance Delta II 7320-10C rocket in July. Once in orbit, OCO-2 will collect precise global measurements of carbon dioxide in the Earth's atmosphere and provide scientists with a better idea of the chemical compound's impacts on climate change. Scientists will analyze this data to improve our understanding of the natural processes and human activities that regulate the abundance and distribution of this important atmospheric gas. To learn more about OCO-2, visit http://oco.jpl.nasa.gov. Photo credit: NASA/Randy Beaudoin

  14. KSC-2014-2126

    NASA Image and Video Library

    2014-04-11

    VANDENBERG AIR FORCE BASE, Calif. – A solid rocket motor, or SRM, for NASA's Orbiting Carbon Observatory-2 mission, or OCO-2, is towed to Space Launch Complex 2 on Vandenberg Air Force Base in California. Operations are underway to attach the Delta II rocket's three SRMs, known as graphite epoxy motors, to the rocket's first stage. OCO-2 is scheduled to launch into a polar Earth orbit aboard a United Launch Alliance Delta II 7320-10C rocket in July. Once in orbit, OCO-2 will collect precise global measurements of carbon dioxide in the Earth's atmosphere and provide scientists with a better idea of the chemical compound's impacts on climate change. Scientists will analyze this data to improve our understanding of the natural processes and human activities that regulate the abundance and distribution of this important atmospheric gas. To learn more about OCO-2, visit http://oco.jpl.nasa.gov. Photo credit: NASA/Randy Beaudoin

  15. KSC-2014-2140

    NASA Image and Video Library

    2014-04-11

    VANDENBERG AIR FORCE BASE, Calif. – A second solid rocket motor, or SRM, for NASA's Orbiting Carbon Observatory-2 mission, or OCO-2, is towed to Space Launch Complex 2 on Vandenberg Air Force Base in California. Operations are underway to attach the Delta II rocket's three SRMs, known as graphite epoxy motors, to the rocket's first stage. OCO-2 is scheduled to launch into a polar Earth orbit aboard a United Launch Alliance Delta II 7320-10C rocket in July. Once in orbit, OCO-2 will collect precise global measurements of carbon dioxide in the Earth's atmosphere and provide scientists with a better idea of the chemical compound's impacts on climate change. Scientists will analyze this data to improve our understanding of the natural processes and human activities that regulate the abundance and distribution of this important atmospheric gas. To learn more about OCO-2, visit http://oco.jpl.nasa.gov. Photo credit: NASA/Randy Beaudoin

  16. Basic Operational Robotics Instructional System

    NASA Technical Reports Server (NTRS)

    Todd, Brian Keith; Fischer, James; Falgout, Jane; Schweers, John

    2013-01-01

    The Basic Operational Robotics Instructional System (BORIS) is a six-degree-of-freedom rotational robotic manipulator system simulation used for training of fundamental robotics concepts, with in-line shoulder, offset elbow, and offset wrist. BORIS is used to provide generic robotics training to aerospace professionals including flight crews, flight controllers, and robotics instructors. It uses forward kinematic and inverse kinematic algorithms to simulate joint and end-effector motion, combined with a multibody dynamics model, moving-object contact model, and X-Windows based graphical user interfaces, coordinated in the Trick Simulation modeling environment. The motivation for development of BORIS was the need for a generic system for basic robotics training. Before BORIS, introductory robotics training was done with either the SRMS (Shuttle Remote Manipulator System) or SSRMS (Space Station Remote Manipulator System) simulations. The unique construction of each of these systems required some specialized training that distracted students from the ideas and goals of the basic robotics instruction.

  17. International Space Station (ISS) Accommodation of a Single US Assured Crew Return Vehicle (ACRV)

    NASA Technical Reports Server (NTRS)

    Mazanek, Daniel D.; Garn, Michelle A.; Troutman, Patrick A.; Wang, Yuan; Kumar, Renjith; Heck, Michael L.

    1997-01-01

    The following report was generated to give the International Space Station (ISS) Program some additional insight into the operations and issues associated with accommodating a single U.S. developed Assured Crew Return Vehicle (ACRV). During the generation of this report, changes in both the ISS and ACRV programs were factored into the analysis with the realization that most of the work performed will eventually need to be repeated once the two programs become more integrated. No significant issues associated with the ISS accommodating the ACRV were uncovered. Kinematic analysis of ACRV installation showed that there are viable methods of using Shuttle and Station robotic manipulators. Separation analysis demonstrated that the ACRV departure path clears the Station structure for all likely contingency scenarios. The payload bay packaging analysis identified trades that can be made between payload bay location, Shuttle Remote Manipulator System (SRMS) reach and eventual designs of de-orbit stages and docking adapters.

  18. [Whole slide imaging technology: from digitization to online applications].

    PubMed

    Ameisen, David; Le Naour, Gilles; Daniel, Christel

    2012-11-01

    As e-health becomes essential to modern care, whole slide images (virtual slides) are now an important clinical, teaching and research tool in pathology. Virtual microscopy consists of digitizing a glass slide by acquiring hundreds of tiles of regions of interest at different zoom levels and assembling them into a structured file. This gigapixel image can then be remotely viewed over a terminal, exactly the way pathologists use a microscope. In this article, we will first describe the key elements of this technology, from the acquisition, using a scanner or a motorized microscope, to the broadcasting of virtual slides through a local or distant viewer over an intranet or Internet connection. As virtual slides are now commonly used in virtual classrooms, clinical data and research databases, we will highlight the main issues regarding its uses in modern pathology. Emphasis will be made on quality assurance policies, standardization and scaling. © 2012 médecine/sciences – Inserm / SRMS.

  19. [Food behaviour and obesity: insights from decision neuroscience].

    PubMed

    Petit, Olivia; Basso, Frédéric; Huguet, Pascal; Plassmann, Hilke; Oullier, Olivier

    2011-11-01

    Neuroimaging allows to estimate brain activity when individuals are doing something. The location and intensity of this estimated activity provides information on the dynamics and processes that guide choice behaviour and associated actions that should be considered a complement to behavioural studies. Decision neuroscience therefore sheds new light on whether the brain evaluates and compares alternatives when decisions are made, or if other processes are at stake. This work helped to demonstrate that the situations faced by individuals (risky, uncertain, delayed in time) do not all have the same (behavioural) complexity, and are not underlined by activity in the cerebral networks. Taking into account brain dynamics of people (suffering from obesity or not) when making food consumption decisions might allow for improved strategies in public health prevention, far from the rational choice theory promoted by neoclassical economics. © 2011 médecine/sciences – Inserm / SRMS.

  20. [Applications of MALDI-TOF-MS in clinical microbiology laboratory].

    PubMed

    Carbonnelle, Etienne; Nassif, Xavier

    2011-10-01

    For twenty years, mass spectrometry (MS) has emerged as a particularly powerful tool for analysis and characterization of proteins in research. It is only recently that this technology, especially MALDI-TOF-MS (Matrix Assisted Laser Desorption Ionization Time-Of-Flight) has entered the field of routine microbiology. This method has proven to be reliable and safe for the identification of bacteria, yeasts, filamentous fungi and dermatophytes. MALDI-TOF-MS is a rapid, precise and cost-effective method for identification, compared to conventional phenotypic techniques or molecular biology. Its ability to analyse whole microorganisms with few sample preparation has greatly reduced the time to identification (1-2 min). Furthermore, this technology can be used to identify bacteria directly from clinical samples as blood culture bottles or urines. Future applications will be developed in order to provide direct information concerning virulence or resistance protein markers. © 2011 médecine/sciences – Inserm / SRMS.

  1. Meteorological assessment of SRM exhaust products' environmental impact

    NASA Technical Reports Server (NTRS)

    Dingle, A. N.

    1982-01-01

    The environmental impact of solid rocket motor (SRM) exhaust products discharged into the free air stream upon the launching of space vehicles that depend upon SRM boosters to obtain large thrust was assessed. The emission of Al2O3 to the troposphere from the SRMs in each Shuttle launch is considered. The Al2O3 appears as particles suitable for heterogeneous nucleation of hydrochloric acid which under frequently occurring atmospheric conditions may form a highly acidic rain capable of damaging property and crops and of impacting upon the health of human and animal populations. The cloud processes leading to the formation of acid rain and the concentration of the acid that then reaches the ground, and the atmospheric situations that lead to the production of cloud and rain at and near a launch site, and the prediction of weather conditions that may permit or prohibit a launch operation are studied.

  2. [Synesthesia as a neuronal palimpsest].

    PubMed

    Hupé, Jean-Michel

    2012-01-01

    Synesthetes, a small fraction of the population, experience systematic, additional associations. For example, they may arbitrarily associate a specific color to each letter or number. Synesthesia has offered for the last ten years to cognitive science a unique opportunity to study the neural bases of subjective experience, drawing on individual differences just like in neuropsychology, but with healthy people. Here we review the current knowledge and propose a new theory, the "palimpsest hypothesis", a variant of the recycling hypothesis for reading. The neural development of written language expertise (a recent cultural invention acquired without any genetic modification) requires indeed the recycling of brain regions predisposed to expertise acquisition into reading regions. The palimpsest hypothesis supposes that for synesthetes recycling involves neuronal networks that were already specialized for color perception. Synesthetic colors would be the remains of this former expertise. © 2012 médecine/sciences – Inserm / SRMS.

  3. [Images in the dialogue between science and society].

    PubMed

    Claessens, Michel

    2011-01-01

    In France, over 45 millions people watch TV every day for more than 3 hours. Science and image get well together since most TV watchers trust this media and rely on it (more than on any other source) for their scientific information. This emphasizes the power of images, which do not always deliver information, but can be naively regarded as creating communication. Image is necessary and an event which does not generate images is a non-event. Images are more than just a support for scientific messages: technologies have produced an enormous amount of images which allow us to uncover the mysteries of the world and Universe, their beauty and delicacy. We can be fascinated by the discovery of the invisible world which surrounds us, and science has truly generated artistic masterpieces even though we should remember that its primary goal is to understand the world rather than to create images. © 2011 médecine/sciences - Inserm / SRMS.

  4. Verification of spatial and temporal pressure distributions in segmented solid rocket motors

    NASA Technical Reports Server (NTRS)

    Salita, Mark

    1989-01-01

    A wide variety of analytical tools are in use today to predict the history and spatial distributions of pressure in the combustion chambers of solid rocket motors (SRMs). Experimental and analytical methods are presented here that allow the verification of many of these predictions. These methods are applied to the redesigned space shuttle booster (RSRM). Girth strain-gage data is compared to the predictions of various one-dimensional quasisteady analyses in order to verify the axial drop in motor static pressure during ignition transients as well as quasisteady motor operation. The results of previous modeling of radial flows in the bore, slots, and around grain overhangs are supported by approximate analytical and empirical techniques presented here. The predictions of circumferential flows induced by inhibitor asymmetries, nozzle vectoring, and propellant slump are compared to each other and to subscale cold air and water tunnel measurements to ascertain their validity.

  5. [Phagocyte migration: an overview].

    PubMed

    Le Cabec, Véronique; Van Goethem, Emeline; Guiet, Romain; Maridonneau-Parini, Isabelle

    2011-12-01

    Phagocytes are the first line of host defense thanks to their capacity to infiltrate infected and wounded tissues, where they exert their bactericidal and tissue repair functions. However, tissue infiltration of phagocytes also stimulates the progression of pathologies such as cancer and chronic inflammatory diseases. It is therefore necessary to identify the molecular and cellular mechanisms that control this process to identify new therapeutic targets. Phagocytes leave the blood stream by crossing the vascular wall and infiltrate interstitial tissues, a three-dimensional environment. A state-of-the-art of the different steps of phagocyte tissue recruitment in vivo and of the different in vitro models is developed in this synthesis. We focus on recent data concerning the migration of phagocytes in three-dimensional environments. The use of two different migration modes, amoeboid and mesenchymal, by macrophages and the role of podosomes and proteases in the mesenchymal migration are discussed. © 2011 médecine/sciences – Inserm / SRMS.

  6. 33 CFR 140.7 - Incorporation by reference.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... materials are incorporated by reference into this subchapter with the approval of the Director of the... material made available to the public. All approved material is available for inspection at U.S. Coast... National Archives and Records Administration (NARA). For information on the availability of this material...

  7. 33 CFR 140.7 - Incorporation by reference.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... materials are incorporated by reference into this subchapter with the approval of the Director of the... material made available to the public. All approved material is available for inspection at U.S. Coast... National Archives and Records Administration (NARA). For information on the availability of this material...

  8. 33 CFR 140.7 - Incorporation by reference.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... materials are incorporated by reference into this subchapter with the approval of the Director of the... material made available to the public. All approved material is available for inspection at U.S. Coast... National Archives and Records Administration (NARA). For information on the availability of this material...

  9. 33 CFR 140.7 - Incorporation by reference.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... materials are incorporated by reference into this subchapter with the approval of the Director of the... material made available to the public. All approved material is available for inspection at U.S. Coast... National Archives and Records Administration (NARA). For information on the availability of this material...

  10. 33 CFR 140.7 - Incorporation by reference.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... materials are incorporated by reference into this subchapter with the approval of the Director of the... material made available to the public. All approved material is available for inspection at U.S. Coast... National Archives and Records Administration (NARA). For information on the availability of this material...

  11. Assessment of Dredged Material Toxicity in San Francisco Bay

    DTIC Science & Technology

    1990-11-01

    reference sediment. When compared to the fine-grain Sequim Bay refer- ence material, no statistically significant mortalities were detected. R...Oakland Harbor. Sequim Bay material was used as the refer- ence. The hierarchy of interspecific sensitivity was oyster larvae > juvenile sand dabs...in San Francisco Bay 6. AUTHOR(S) Thomas M. Dillon, David W. Moore 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) - 8. PERFORMING ORGANIZATION

  12. Methods and instruments for materials testing

    NASA Technical Reports Server (NTRS)

    Hansma, Paul (Inventor); Drake, Barney (Inventor); Rehn, Douglas (Inventor); Adams, Jonathan (Inventor); Lulejian, Jason (Inventor)

    2011-01-01

    Methods and instruments for characterizing a material, such as the properties of bone in a living human subject, using a test probe constructed for insertion into the material and a reference probe aligned with the test probe in a housing. The housing is hand held or placed so that the reference probe contacts the surface of the material under pressure applied either by hand or by the weight of the housing. The test probe is inserted into the material to indent the material while maintaining the reference probe substantially under the hand pressure or weight of the housing allowing evaluation of a property of the material related to indentation of the material by the probe. Force can be generated by a voice coil in a magnet structure to the end of which the test probe is connected and supported in the magnet structure by a flexure, opposing flexures, a linear translation stage, or a linear bearing. Optionally, a measurement unit containing the test probe and reference probe is connected to a base unit with a wireless connection, allowing in the field material testing.

  13. Ultrasonic angle beam standard reflector. [ultrasonic nondestructive inspection

    NASA Technical Reports Server (NTRS)

    Berry, R. F., Jr. (Inventor)

    1985-01-01

    A method that provides an impression profile in a reference standard material utilized in inspecting critically stressed components with pulsed ultrasound is described. A die stamp having an I letter is used to impress the surface of a reference material. The die stamp is placed against the surface and struck with an inertia imparting member to impress the I in the reference standard material. Upset may appear on the surface as a result of the impression and is removed to form a smooth surface. The stamping and upset removal is repeated until the entire surface area of a depth control platform on the die stamp uniformly contacts the material surface. The I impression profile in the reference standard material is utilized for reflecting pulsed ultrasonic beams for inspection purposes.

  14. 15 CFR 230.7 - Description of services and list of fees, incorporation by reference.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... STANDARD REFERENCE MATERIALS STANDARD REFERENCE MATERIALS Description of Services and List of Fees § 230.7 Description of services and list of fees, incorporation by reference. (a) The text of NIST Special Publication... 15 Commerce and Foreign Trade 1 2010-01-01 2010-01-01 false Description of services and list of...

  15. National Nutrition Education Clearing House Reference List, Preschool, Primary and Intermediate Teaching Materials and Teacher References.

    ERIC Educational Resources Information Center

    National Nutrition Education Clearing House, Berkeley, CA.

    This is a reference list of teaching materials and teacher references of importance to teachers in the field of nutrition and nutrition education. It emphasizes resources for preschool, primary and intermediate grades. Although not a comprehensive list, resources include books, pamphlets, curriculum guides, article reprints, films and filmstrips,…

  16. Interlaboratory Reproducibility of Droplet Digital Polymerase Chain Reaction Using a New DNA Reference Material Format.

    PubMed

    Pinheiro, Leonardo B; O'Brien, Helen; Druce, Julian; Do, Hongdo; Kay, Pippa; Daniels, Marissa; You, Jingjing; Burke, Daniel; Griffiths, Kate; Emslie, Kerry R

    2017-11-07

    Use of droplet digital PCR technology (ddPCR) is expanding rapidly in the diversity of applications and number of users around the world. Access to relatively simple and affordable commercial ddPCR technology has attracted wide interest in use of this technology as a molecular diagnostic tool. For ddPCR to effectively transition to a molecular diagnostic setting requires processes for method validation and verification and demonstration of reproducible instrument performance. In this study, we describe the development and characterization of a DNA reference material (NMI NA008 High GC reference material) comprising a challenging methylated GC-rich DNA template under a novel 96-well microplate format. A scalable process using high precision acoustic dispensing technology was validated to produce the DNA reference material with a certified reference value expressed in amount of DNA molecules per well. An interlaboratory study, conducted using blinded NA008 High GC reference material to assess reproducibility among seven independent laboratories demonstrated less than 4.5% reproducibility relative standard deviation. With the exclusion of one laboratory, laboratories had appropriate technical competency, fully functional instrumentation, and suitable reagents to perform accurate ddPCR based DNA quantification measurements at the time of the study. The study results confirmed that NA008 High GC reference material is fit for the purpose of being used for quality control of ddPCR systems, consumables, instrumentation, and workflow.

  17. The Kjeldahl method as a primary reference procedure for total protein in certified reference materials used in clinical chemistry. II. Selection of direct Kjeldahl analysis and its preliminary performance parameters.

    PubMed

    Vinklárková, Bára; Chromý, Vratislav; Šprongl, Luděk; Bittová, Miroslava; Rikanová, Milena; Ohnútková, Ivana; Žaludová, Lenka

    2015-01-01

    To select a Kjeldahl procedure suitable for the determination of total protein in reference materials used in laboratory medicine, we reviewed in our previous article Kjeldahl methods adopted by clinical chemistry and found an indirect two-step analysis by total Kjeldahl nitrogen corrected for its nonprotein nitrogen and a direct analysis made on isolated protein precipitates. In this article, we compare both procedures on various reference materials. An indirect Kjeldahl method gave falsely lower results than a direct analysis. Preliminary performance parameters qualify the direct Kjeldahl analysis as a suitable primary reference procedure for the certification of total protein in reference laboratories.

  18. 49 CFR 572.80 - Incorporated materials.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 7 2011-10-01 2011-10-01 false Incorporated materials. 572.80 Section 572.80... Incorporated materials. The drawings and specifications referred to in § 572.81(a) that are not set forth in full are hereby incorporated in this part by reference. These materials are thereby made part of this...

  19. 10 CFR 431.15 - Materials incorporated by reference.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... approval, and a notice of any change in the material will be published in the Federal Register. All... 10 Energy 3 2014-01-01 2014-01-01 false Materials incorporated by reference. 431.15 Section 431.15... INDUSTRIAL EQUIPMENT Electric Motors Test Procedures, Materials Incorporated and Methods of Determining...

  20. 49 CFR 572.80 - Incorporated materials.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 7 2012-10-01 2012-10-01 false Incorporated materials. 572.80 Section 572.80... Incorporated materials. The drawings and specifications referred to in § 572.81(a) that are not set forth in full are hereby incorporated in this part by reference. These materials are thereby made part of this...

  1. 49 CFR 572.80 - Incorporated materials.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 7 2013-10-01 2013-10-01 false Incorporated materials. 572.80 Section 572.80... Incorporated materials. The drawings and specifications referred to in § 572.81(a) that are not set forth in full are hereby incorporated in this part by reference. These materials are thereby made part of this...

  2. 49 CFR 572.40 - Incorporated materials.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Register has approved the materials incorporated by reference. For materials subject to change, only the... incorporated. A notice of any change will be published in the Federal Register. As a convenience to the reader... volume of the Code of Federal Regulations. (b) The materials incorporated in this part by reference are...

  3. Development of potential candidate reference materials for drugs in bottom sediment, cod and herring tissues.

    PubMed

    Baranowska, Irena; Buszewski, Bogusław; Namieśnik, Jacek; Konieczka, Piotr; Magiera, Sylwia; Polkowska-Motrenko, Halina; Kościelniak, Paweł; Gadzała-Kopciuch, Renata; Woźniakiewicz, Aneta; Samczyński, Zbigniew; Kochańska, Kinga; Rutkowska, Małgorzata

    2017-02-01

    Regular use of a reference material and participation in a proficiency testing program can improve the reliability of analytical data. This paper presents the preparation of candidate reference materials for the drugs metoprolol, propranolol, carbamazepine, naproxen, and acenocoumarol in freshwater bottom sediment and cod and herring tissues. These reference materials are not available commercially. Drugs (between 7 ng/g and 32 ng/g) were added to the samples, and the spiked samples were freeze-dried, pulverized, sieved, homogenized, bottled, and sterilized by γ-irradiation to prepare the candidate materials. Procedures for extraction and liquid chromatography coupled with tandem mass spectrometry were developed to determine the drugs of interest in the studied material. Each target drug was quantified using two analytical procedures, and the results obtained from these two procedures were in good agreement with each other. Stability and homogeneity assessments were performed, and the relative uncertainties due to instability (for an expiration date of 12 months) and inhomogeneity were 10-25% and 4.0-6.8%, respectively. These procedures will be useful in the future production of reference materials. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Assessment of international reference materials for isotope-ratio analysis (IUPAC Technical Report)

    USGS Publications Warehouse

    Brand, Willi A.; Coplen, Tyler B.; Vogl, Jochen; Rosner, Martin; Prohaska, Thomas

    2014-01-01

    Since the early 1950s, the number of international measurement standards for anchoring stable isotope delta scales has mushroomed from 3 to more than 30, expanding to more than 25 chemical elements. With the development of new instrumentation, along with new and improved measurement procedures for studying naturally occurring isotopic abundance variations in natural and technical samples, the number of internationally distributed, secondary isotopic reference materials with a specified delta value has blossomed in the last six decades to more than 150 materials. More than half of these isotopic reference materials were produced for isotope-delta measurements of seven elements: H, Li, B, C, N, O, and S. The number of isotopic reference materials for other, heavier elements has grown considerably over the last decade. Nevertheless, even primary international measurement standards for isotope-delta measurements are still needed for some elements, including Mg, Fe, Te, Sb, Mo, and Ge. It is recommended that authors publish the delta values of internationally distributed, secondary isotopic reference materials that were used for anchoring their measurement results to the respective primary stable isotope scale.

  5. Determination of tungsten in geochemical reference material basalt Columbia River 2 by radiochemical neutron activation analysis and inductively coupled plasma mass spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morrison, Samuel S.; Beck, Chelsie L.; Bowen, James M.

    Environmental tungsten (W) analyses are inhibited by a lack of reference materials and practical methods to remove isobaric and radiometric interferences. We present a method that evaluates the potential use of commercially available sediment, Basalt Columbia River-2 (BCR-2), as a reference material using neutron activation analysis (NAA) and mass spectrometry. Tungsten concentrations using both methods are in statistical agreement at the 95% confidence interval (92 ± 4 ng/g for NAA and 100 ±7 ng/g for mass spectrometry) with recoveries greater than 95%. These results indicate that BCR-2 may be suitable as a reference material for future studies.

  6. Diffusion-controlled reference material for VOC emissions testing: proof of concept.

    PubMed

    Cox, S S; Liu, Z; Little, J C; Howard-Reed, C; Nabinger, S J; Persily, A

    2010-10-01

    Because of concerns about indoor air quality, there is growing awareness of the need to reduce the rate at which indoor materials and products emit volatile organic compounds (VOCs). To meet consumer demand for low emitting products, manufacturers are increasingly submitting materials to independent laboratories for emissions testing. However, the same product tested by different laboratories can result in very different emissions profiles because of a general lack of test validation procedures. There is a need for a reference material that can be used as a known emissions source and that will have the same emission rate when tested by different laboratories under the same conditions. A reference material was created by loading toluene into a polymethyl pentene film. A fundamental emissions model was used to predict the toluene emissions profile. Measured VOC emissions profiles using small-chamber emissions tests compared reasonably well to the emissions profile predicted using the emissions model, demonstrating the feasibility of the proposed approach to create a diffusion-controlled reference material. To calibrate emissions test chambers and improve the reproducibility of VOC emission measurements among different laboratories, a reference material has been created using a polymer film loaded with a representative VOC. Initial results show that the film's VOC emission profile measured in a conventional test chamber compares well to predictions based on independently determined material/chemical properties and a fundamental emissions model. The use of such reference materials has the potential to build consensus and confidence in emissions testing as well as 'level the playing field' for product testing laboratories and manufacturers.

  7. Certification of biological candidates reference materials by neutron activation analysis

    NASA Astrophysics Data System (ADS)

    Kabanov, Denis V.; Nesterova, Yulia V.; Merkulov, Viktor G.

    2018-03-01

    The paper gives the results of interlaboratory certification of new biological candidate reference materials by neutron activation analysis recommended by the Institute of Nuclear Chemistry and Technology (Warsaw, Poland). The correctness and accuracy of the applied method was statistically estimated for the determination of trace elements in candidate reference materials. The procedure of irradiation in the reactor thermal fuel assembly without formation of fast neutrons was carried out. It excluded formation of interfering isotopes leading to false results. The concentration of more than 20 elements (e.g., Ba, Br, Ca, Co, Ce, Cr, Cs, Eu, Fe, Hf, La, Lu, Rb, Sb, Sc, Ta, Th, Tb, Yb, U, Zn) in candidate references of tobacco leaves and bottom sediment compared to certified reference materials were determined. It was shown that the average error of the applied method did not exceed 10%.

  8. Quality assurance and quality control in light stable isotope laboratories: A case study of Rio Grande, Texas, water samples

    USGS Publications Warehouse

    Coplen, T.B.; Qi, H.

    2009-01-01

    New isotope laboratories can achieve the goal of reporting the same isotopic composition within analytical uncertainty for the same material analysed decades apart by (1) writing their own acceptance testing procedures and putting them into their mass spectrometric or laser-based isotope-ratio equipment procurement contract, (2) requiring a manufacturer to demonstrate acceptable performance using all sample ports provided with the instrumentation, (3) for each medium to be analysed, prepare two local reference materials substantially different in isotopic composition to encompass the range in isotopic composition expected in the laboratory and calibrated them with isotopic reference materials available from the International Atomic Energy Agency (IAEA) or the US National Institute of Standards and Technology (NIST), (4) using the optimum storage containers (for water samples, sealing in glass ampoules that are sterilised after sealing is satisfactory), (5) interspersing among sample unknowns local laboratory isotopic reference materials daily (internationally distributed isotopic reference materials can be ordered at three-year intervals, and can be used for elemental analyser analyses and other analyses that consume less than 1 mg of material) - this process applies to H, C, N, O, and S isotope ratios, (6) calculating isotopic compositions of unknowns by normalising isotopic data to that of local reference materials, which have been calibrated to internationally distributed isotopic reference materials, (7) reporting results on scales normalised to internationally distributed isotopic reference materials (where they are available) and providing to sample submitters the isotopic compositions of internationally distributed isotopic reference materials of the same substance had they been analysed with unknowns, (8) providing an audit trail in the laboratory for analytical results - this trail commonly will be in electronic format and might include a laboratory information management system, (9) making at regular intervals a complete backup of laboratory analytical data (both of samples logged into the laboratory and of mass spectrometric analyses), being sure to store one copy of this backup offsite, and (10) participating in interlaboratory comparison exercises sponsored by the IAEA and other agencies at regular intervals. ?? Taylor & Francis.

  9. Development of Lentivirus-Based Reference Materials for Ebola Virus Nucleic Acid Amplification Technology-Based Assays.

    PubMed

    Mattiuzzo, Giada; Ashall, James; Doris, Kathryn S; MacLellan-Gibson, Kirsty; Nicolson, Carolyn; Wilkinson, Dianna E; Harvey, Ruth; Almond, Neil; Anderson, Robert; Efstathiou, Stacey; Minor, Philip D; Page, Mark

    2015-01-01

    The 2013-present Ebola virus outbreak in Western Africa has prompted the production of many diagnostic assays, mostly based on nucleic acid amplification technologies (NAT). The calibration and performance assessment of established assays and those under evaluation requires reference materials that can be used in parallel with the clinical sample to standardise or control for every step of the procedure, from extraction to the final qualitative/quantitative result. We have developed safe and stable Ebola virus RNA reference materials by encapsidating anti sense viral RNA into HIV-1-like particles. The lentiviral particles are replication-deficient and non-infectious due to the lack of HIV-1 genes and Envelope protein. Ebola virus genes were subcloned for encapsidation into two lentiviral preparations, one containing NP-VP35-GP and the other VP40 and L RNA. Each reference material was formulated as a high-titre standard for use as a calibrator for secondary or internal standards, and a 10,000-fold lower titre preparation to serve as an in-run control. The preparations have been freeze-dried to maximise stability. These HIV-Ebola virus RNA reference materials were suitable for use with in-house and commercial quantitative RT-PCR assays and with digital RT-PCR. The HIV-Ebola virus RNA reference materials are stable at up to 37°C for two weeks, allowing the shipment of the material worldwide at ambient temperature. These results support further evaluation of the HIV-Ebola virus RNA reference materials as part of an International collaborative study for the establishment of the 1st International Standard for Ebola virus RNA.

  10. [Effect of emotional content and self reference of learning materials on recall performance].

    PubMed

    Spies, K

    1994-01-01

    It is assumed that high affective value and high self-reference of learning material help to improve memory performance as these factors allow better memory consolidation (activation hypothesis) or better integration of the new material into existing knowledge structures (extent-of-processing hypothesis). To test this assumption, 60 subjects were shown 16 short advertising films characterized by low vs. high affective value and low vs. high self-reference. Both factors were varied within subjects. After the films had each been presented twice, subjects had to recall the product names and answer two questions to each film. Results showed for both dependent variables that films with high affective values were better remembered than films with low affective values. The same held true--though to a lower extent--with respect to self-reference. According to the expected linear trend, performance was best for material scoring high on affective value as well as on self-reference, while it was worst for material scoring low on both factors.

  11. Certification of caffeine reference material purity by ultraviolet/visible spectrophotometry and high-performance liquid chromatography with diode-array detection as two independent analytical methods.

    PubMed

    Shehata, A B; Rizk, M S; Rend, E A

    2016-10-01

    Caffeine reference material certified for purity is produced worldwide, but no research work on the details of the certification process has been published in the literature. In this paper, we report the scientific details of the preparation and certification of pure caffeine reference materials. Caffeine was prepared by extraction from roasted and ground coffee by dichloromethane after heating in deionized water mixed with magnesium oxide. The extract was purified, dried, and bottled in dark glass vials. Stratified random selection was applied to select a number of vials for homogeneity and stability studies, which revealed that the prepared reference material is homogeneous and sufficiently stable. Quantification of caffeine purity % was carried out using a calibrated UV/visible spectrophotometer and a calibrated high-performance liquid chromatography with diode-array detection method. The results obtained from both methods were combined to drive the certified value and its associated uncertainty. The certified value of the reference material purity was found to be 99.86% and its associated uncertainty was ±0.65%, which makes the candidate reference material a very useful calibrant in food and drug chemical analysis. Copyright © 2016. Published by Elsevier B.V.

  12. [Printed material distributed by pharmaceutical propaganda agents].

    PubMed

    Mejía, R; Avalos, A

    2001-01-01

    Pharmaceutical sales representatives (drug reps) frequently visit 70% to 90% of physicians during their daily clinical practice and many consider the promotional printed material to be a major source of clinical information. We evaluated samples of the promotional printed material distributed to physicians by drug reps in order to determine whether the data contained in the promotional material is correct and supported by references accessible in Argentina. A consecutive sample of all the promotional material distributed by drug reps in the general internal medicine program (Hospital de Clínicas) was collected between March 15 and April 15, 2000. Reprints and monographs were excluded. Clinical information was reviewed by two general internists and compared to information in a major pharmacology textbook and in an electronic medical information program. References cited were reviewed for correct listing and accessibility in any of the four major medical libraries in Buenos Aires. Of the sixty-four pieces of promotional material collected, thirty were randomly selected and evaluated. In twenty one (70%) the therapeutic effect promoted in advertisement appeared in Goodman & Gilman's 9th edition textbook of pharmacology, in the pharmacology section of the Up-to-Date version 8.1 or in both. Only eighteen (60%) of the thirty promotional printed material evaluated had statements supported by cited references. From a total of 131 references cited in promotional materials, sixty (46%) were incorrectly listed according to the International Committee of Medical Journal Editors. These references were inaccessible. Of the 71 references correctly cited, 49 (69%) were not available in any of the four major medical libraries in Buenos Aires and 8 were available in only two of the libraries. Twenty-two references were reviewed, and in twelve of these (54%), the objective of the research study concurred with the statement of the promotional printed material. Adverse reactions, warnings about drug interactions and contraindications were absent from all promotional printed material. It can be concluded that the promotional printed material distributed by the drug reps in Buenos Aires are biased and provide misinformation more often than not. We recommend that practicing physicians routinely disregard promotional printed material as a source of clinical information.

  13. Real-time sonoelastography using an external reference material: test-retest reliability of healthy Achilles tendons.

    PubMed

    Schneebeli, Alessandro; Del Grande, Filippo; Vincenzo, Gabriele; Cescon, Corrado; Clijsen, Ron; Biordi, Fulvio; Barbero, Marco

    2016-08-01

    To establish the test-retest reliability of sonoelastography (SE) on healthy Achilles tendons in contracted and relaxed states using an external reference system. Forty-eight Achilles tendons from 24 healthy volunteers were assessed using ultrasound and real-time SE with an external reference material. Tendons were analyzed under relaxed and contracted conditions. Strain ratios between the tendons and the reference material were calculated. The intraclass correlation coefficient (ICC2.k) and Bland-Altman plot were used to assess test-retest reliability. The reliability of SE measurements under relaxed conditions ranged from high to very high, with an ICC2.k of 0.84 (95 % CI: 0.64-0.92) for reference material, 0.91 (95 % CI: 0.83-0.95) for Achilles tendons and 0.95 (95 % CI: 0.91-0.97) for Kager fat pads (KFP). The ICC2.k value for skin was 0.30 (95 % CI: -0.26 to 0.61). Reliability for measurements in the contracted state ranged from high to very high, with an ICC2.k of 0.93 (95 % CI: 0.87-0.96) for reference material, 0.72 (95 % CI: 0.50-0.84) for skin, 0.93 (95 % CI: 0.87-0.96) for Achilles tendons, and 0.81 (95 % CI: 0.66-0.89) for KFP. Reliability of the strain ratio (tendon/reference) under relaxed conditions was high with an ICC2.k of 0.87 (95 % CI: 0.75-0.93), and in the contracted state, it was very high with an ICC2.k of 0.94 (95 % CI: 0.90-0.97). Sonoelastography using an external reference material is a reliable and simple technique for the assessment of the elasticity of healthy Achilles tendons. The use of an external material as a reference, along with strain ratios, could provide a quantitative measure of elasticity.

  14. 40 CFR 94.5 - Reference materials.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    .../code_of_federal_regulations/ibr_locations.html. (a) ASTM material. Table 1 of § 94.5 lists material... of § 94.5—ASTM Materials Document No. and name Part 94 reference ASTM D 86-01, Standard Test Method for Distillation of Petroleum Products at Atmospheric Pressure 94.108 ASTM D 93-02, Standard Test...

  15. 10 CFR 431.443 - Materials incorporated by reference.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... the date of the approval and a notice of any change in the material will be published in the Federal... 10 Energy 3 2014-01-01 2014-01-01 false Materials incorporated by reference. 431.443 Section 431... AND INDUSTRIAL EQUIPMENT Small Electric Motors Test Procedures § 431.443 Materials incorporated by...

  16. Thermal ablation of a confluent lesion in the porcine kidney with a clinically available MR-HIFU system

    NASA Astrophysics Data System (ADS)

    van Breugel, J. M. M.; de Greef, M.; Wijlemans, J. W.; Schubert, G.; van den Bosch, M. A. A. J.; Moonen, C. T. W.; Ries, M. G.

    2017-07-01

    The incidence of small renal masses (SRMs) sized  <4 cm has increased over the decades (as co-findings/or due to introduction of cross sectional imaging). Currently, partial nephrectomy (PN) or watchful waiting is advised in these patients. Ultimately, 80-90% of these SRMs require surgical treatment and PN is associated with a 15% complication rate. In this aging population, with possible comorbidities and poor health condition, both PN and watchful waiting are non-ideal treatment options. This resulted in an increased need for early, non-invasive treatment strategies such as MR-guided high intensity focused ultrasound (MR-HIFU). (i) To investigate the feasibility of creating a confluent lesion in the kidney using respiratory-gated MR-HIFU under clinical conditions in a pre-clinical study and (ii) to evaluate the reproducibility of the MR-HIFU ablation strategy. Healthy pigs (n  =  10) under general anesthesia were positioned on a clinical MR-HIFU system with integrated cooling. A honeycomb pattern of seven overlapping ablation cells (4  ×  4  ×  10 mm3, 450 W, <30 s) was ablated successively in the cortex of the porcine kidney. Both MR thermometry and acoustic energy delivery were respiratory gated using a pencil beam navigator on the contralateral kidney. The non-perfused volume (NPV) was visualized after the last sonication by contrast-enhanced (CE) T 1-weighted MR (T 1 w) imaging. Cell viability staining was performed to visualize the extent of necrosis. Results: a median NPV of 0.62 ml was observed on CE-T 1 w images (IQR 0.58-1.57 ml, range 0.33-2.75 ml). Cell viability staining showed a median damaged volume of 0.59 ml (IQR 0.24-1.35 ml, range 0-4.1 ml). Overlooking of the false rib, shivering of the pig, and too large depth combined with a large heat-sink effect resulted in insufficient heating in 4 cases. The NPV and necrosed volume were confluent in all cases in which an ablated volume could be observed. Our results demonstrated the feasibility of creating a confluent volume of ablated kidney cortical tissue in vivo with MR-HIFU on a clinically available system using respiratory gating and near-field cooling and showed its reproducibility.

  17. The Solid Rocket Motor Slag Population: Results of a Radar-Based Regressive Statistical Evaluation

    NASA Technical Reports Server (NTRS)

    Horstman, Matthew F.; Xu, Yu-Lin

    2008-01-01

    Solid rocket motor (SRM) slag has been identified as a potential source of man-made orbital debris. The possibility that SRMs (in addition to generating dust particles in the sub-millimeter range) may generate particles up to centimeters in size has caused concern regarding their contribution to the debris environment. Returned surfaces from space do not have sufficient area or exposure time to provide a clear picture of the SRM millimeter and centimeter debris population. Currently, radar observation is probably the only way to collect data showing the debris contribution from SRMs. Such observation is used to sample the debris environment, but it is difficult to obtain accurate orbital elements for the detected debris objects. NASA has developed several models to describe the different orbital debris populations, based on assumed debris production mechanisms to create clouds of debris objects that can be propagated in time. The NASA model, LEGEND (LEO-to-GEO Environment Debris), functions as a time-tested debris model for most debris sources. However, the current LEGEND model does not include contributions from the SRM population. An SRM model has recently been developed by NASA, based on purely theoretical details of SRM production and known SRM launches, but verification with hard data is needed. Because the detections of individual SRM objects cannot be deterministically separated from the total debris observed by radar, the validation of the SRM model can only be done by combining it with the LEGEND breakup model and comparing it with data. By applying observational constraints, the degree of SRM slag contribution to the environment may be estimated. This serves as an observationally sound method from which to calibrate a purely theoretical model into something more realistic. For this study, we use the populations observed by the Haystack radar from 1996 to present. For the SRM debris, we use a historical database of SRM launches, propellant masses, and estimated locations and times of tailoff to produce and propagate the SRM debris clouds. Comparisons with radar data from the ensuing years were made, and the SRM model was altered with respect to size and mass production of slag particles to reflect the populations estimated from the data. The result is a model SRM population that fits within the bounds of the observed environment and estimates of the production and contribution of SRM debris to the environment.

  18. Transportation research synthesis : ADA compliance reference and training materials.

    DOT National Transportation Integrated Search

    2010-03-01

    Our findings are presented in three categories: Reference Materials, Training Materials and State DOT Current : Practices. Appendix A to this report contains an updated list of ADA contacts for all 50 states and the District of : Columbia, and Append...

  19. Carroll County Competency Based Teacher Certification Project. Librarian's Report.

    ERIC Educational Resources Information Center

    Coker, Homer; Coker, Joan G.

    Reference materials, slides, cassettes, books, pamphlets, materials from other states, and articles used in the Carroll County, Georgia, Competency Based Teacher Certification Project, 1973-74, are listed. Brief annotations are included for both the reference materials and articles. (MJM)

  20. Achieving Excellence in Library Instruction.

    ERIC Educational Resources Information Center

    Gilbert, Betty; And Others

    The materials included in this document supporting library instruction are divided into two chapters. The first chapter contains bibliographies of instructional materials, professional periodicals, general reference tools, and religious reference tools. Throughout the bibliographies, the approximate cost of the materials is indicated by dollar…

  1. The characterization and certification of a quantitative reference material for Legionella detection and quantification by qPCR.

    PubMed

    Baume, M; Garrelly, L; Facon, J P; Bouton, S; Fraisse, P O; Yardin, C; Reyrolle, M; Jarraud, S

    2013-06-01

    The characterization and certification of a Legionella DNA quantitative reference material as a primary measurement standard for Legionella qPCR. Twelve laboratories participated in a collaborative certification campaign. A candidate reference DNA material was analysed through PCR-based limiting dilution assays (LDAs). The validated data were used to statistically assign both a reference value and an associated uncertainty to the reference material. This LDA method allowed for the direct quantification of the amount of Legionella DNA per tube in genomic units (GU) and the determination of the associated uncertainties. This method could be used for the certification of all types of microbiological standards for qPCR. The use of this primary standard will improve the accuracy of Legionella qPCR measurements and the overall consistency of these measurements among different laboratories. The extensive use of this certified reference material (CRM) has been integrated in the French standard NF T90-471 (April 2010) and in the ISO Technical Specification 12 869 (Anon 2012 International Standardisation Organisation) for validating qPCR methods and ensuring the reliability of these methods. © 2013 The Society for Applied Microbiology.

  2. USGS reference materials

    USGS Publications Warehouse

    ,

    1995-01-01

    Every year in the United States, millions of measurements are made on the chemical composition of items that affect us on a daily basis. Determining the accuracy of these measurements is based on the analysis of appropriate reference materials whose composition was previously determined through rigorous testing. Today, reference materials help us evaluate the composition of the food we eat, medicine we use, soil we grow our crops in, and hundreds of other products that affect our everyday lives.

  3. Building Trades. Block VIII. Interior Trim.

    ERIC Educational Resources Information Center

    Texas A and M Univ., College Station. Vocational Instructional Services.

    This curriculum for interior trim provides instructional materials for 18 informational and manipulative lessons. A list of 11 references precedes the course materials. The instructor's plan for each informational lesson begins by providing this information: subject, aim, required teaching aids, required materials, references, and prerequisite…

  4. 40 CFR 1048.810 - What materials does this part reference?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....org. Table 1 follows: Table 1 of § 1048.810—SAE Materials Document number and name Part 1048reference..., Switzerland or http://www.iso.org. Table 2 follows: Table 2 of § 1048.810—ISO Materials Document number and...

  5. 14 CFR 171.71 - Materials incorporated by reference.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Headquarters. An historical file of these materials is maintained at Headquarters, Federal Aviation... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Materials incorporated by reference. 171.71 Section 171.71 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION...

  6. 14 CFR 171.71 - Materials incorporated by reference.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Headquarters. An historical file of these materials is maintained at Headquarters, Federal Aviation... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Materials incorporated by reference. 171.71 Section 171.71 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION...

  7. 14 CFR 171.71 - Materials incorporated by reference.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Headquarters. An historical file of these materials is maintained at Headquarters, Federal Aviation... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Materials incorporated by reference. 171.71 Section 171.71 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION...

  8. 14 CFR 171.71 - Materials incorporated by reference.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Headquarters. An historical file of these materials is maintained at Headquarters, Federal Aviation... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Materials incorporated by reference. 171.71 Section 171.71 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION...

  9. 14 CFR 171.71 - Materials incorporated by reference.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Headquarters. An historical file of these materials is maintained at Headquarters, Federal Aviation... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Materials incorporated by reference. 171.71 Section 171.71 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION...

  10. Standard and reference materials for marine science. Third edition. Technical memo

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cantillo, A.Y.

    1992-08-01

    The third edition of the catalog of reference materials suited for use in marine science, originally compiled in 1986 for NOAA, IOC, and UNEP. The catalog lists close to 2,000 reference materials from sixteen producers and contains information about their proper use, sources, availability, and analyte concentrations. Indices are included for elements, isotopes, and organic compounds, as are cross references to CAS registry numbers, alternate names, and chemical structures of selected organic compounds. The catalog is being published independently by both NOAA and IOC/UNEP and is available from NOAA/NOS/ORCA in electronic form.

  11. Locating interfaces in vertically-layered materials and determining concentrations in mixed materials utilizing acoustic impedance measurements

    DOEpatents

    Langlois, Gary N.

    1983-09-13

    Measurement of the relative and actual value of acoustic characteristic impedances of an unknown substance, location of the interfaces of vertically-layered materials, and the determination of the concentration of a first material mixed in a second material. A highly damped ultrasonic pulse is transmitted into one side of a reference plate, such as a tank wall, where the other side of the reference plate is in physical contact with the medium to be measured. The amplitude of a return signal, which is the reflection of the transmitted pulse from the interface between the other side of the reference plate and the medium, is measured. The amplitude value indicates the acoustic characteristic impedance of the substance relative to that of the reference plate or relative to that of other tested materials. Discontinuities in amplitude with repeated measurements for various heights indicate the location of interfaces in vertically-layered materials. Standardization techniques permit the relative acoustic characteristic impedance of a substance to be converted to an actual value. Calibration techniques for mixtures permit the amplitude to be converted to the concentration of a first material mixed in a second material.

  12. Locating interfaces in vertically-layered materials and determining concentrations in mixed materials utilizing acoustic impedance measurements

    DOEpatents

    Langlois, G.N.

    1983-09-13

    Measurement of the relative and actual value of acoustic characteristic impedances of an unknown substance, location of the interfaces of vertically-layered materials, and the determination of the concentration of a first material mixed in a second material are disclosed. A highly damped ultrasonic pulse is transmitted into one side of a reference plate, such as a tank wall, where the other side of the reference plate is in physical contact with the medium to be measured. The amplitude of a return signal, which is the reflection of the transmitted pulse from the interface between the other side of the reference plate and the medium, is measured. The amplitude value indicates the acoustic characteristic impedance of the substance relative to that of the reference plate or relative to that of other tested materials. Discontinuities in amplitude with repeated measurements for various heights indicate the location of interfaces in vertically-layered materials. Standardization techniques permit the relative acoustic characteristic impedance of a substance to be converted to an actual value. Calibration techniques for mixtures permit the amplitude to be converted to the concentration of a first material mixed in a second material. 6 figs.

  13. Preparation of canine C-reactive protein serum reference material: A feasibility study.

    PubMed

    Canalias, Francesca; Piñeiro, Matilde; Pato, Raquel; Peña, Raquel; Bosch, Lluís; Soler, Lourdes; García, Natalia; Lampreave, Fermín; Saco, Yolanda; Bassols, Anna

    2018-03-01

    The availability of a species-specific reference material is essential for the harmonization of results obtained in different laboratories by different methods. We describe the preparation of a canine C-reactive protein (cCRP) serum reference material containing purified cCRP stabilized in a serum matrix. The material can be used by manufacturers to assign values to their calibrator and control materials. The serum matrix was obtained using blood collected from healthy dogs, stabilized and submitted for a delipidation process. The reference material was prepared by diluting purified cCRP in the serum matrix containing 1.0 mol/L HEPES buffer, 3.0 mmol/L calcium chloride, 80,000 kUI/L aprotinin, and 1.0 mmol/L benzamidine hydrochloride monohydrate at a pH of 7.2, and dispensing (0.5 mL) the matrix into vials that were then frozen. The pilot batch of 200 vials was shown to be homogeneous and stable after a stability study at various temperatures and over a total time of 110 days. The prepared material was submitted to an assignment value study. Eight laboratories from different European countries participated by using the same reagents for an immunoturbidimetric method adapted for different analyzers. The obtained cCRP concentration in the reference material was 78.5 mg/L with an expanded uncertainty (k = 2) of 4.2 mg/L. Canine C-reactive protein serum reference material has been produced that allows harmonization of results obtained by different methods and different laboratories, thus reducing the possibility of errors and misunderstandings. © 2018 American Society for Veterinary Clinical Pathology.

  14. Bibliography for the Hospitality Industry.

    ERIC Educational Resources Information Center

    Nelson, Elizabeth A.

    This annotated bibliography is a sample collection of reference materials in the hospitality industry suitable for a small academic library. It is assumed that the library has a general reference collection. Publication dates range from 1992-96, with two publication dates in the 1980s. No periodicals are included. The 41 reference materials are…

  15. 49 CFR 511.53 - Appeal from initial decision.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... position taken on each question, with specific page references to the record and legal or other material... matters in the brief, with page references, and a table of cases (alphabetically arranged), textbooks, statutes, and other material cited, with page references thereto; (2) A concise statement of the case; (3...

  16. 49 CFR 511.53 - Appeal from initial decision.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... position taken on each question, with specific page references to the record and legal or other material... matters in the brief, with page references, and a table of cases (alphabetically arranged), textbooks, statutes, and other material cited, with page references thereto; (2) A concise statement of the case; (3...

  17. 49 CFR 511.53 - Appeal from initial decision.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... position taken on each question, with specific page references to the record and legal or other material... matters in the brief, with page references, and a table of cases (alphabetically arranged), textbooks, statutes, and other material cited, with page references thereto; (2) A concise statement of the case; (3...

  18. 40 CFR 91.6 - Reference materials.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... EMISSIONS FROM MARINE SPARK-IGNITION ENGINES General § 91.6 Reference materials. (a) Incorporation by... the Research Method Appendix A to Subpart D. ASTM D2700-92: Standard Test Method for Knock... 40 CFR part 91 reference SAE J1228/ISO 8665 November 1991 Small Craft-Marine Propulsion Engine and...

  19. 40 CFR 91.6 - Reference materials.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... EMISSIONS FROM MARINE SPARK-IGNITION ENGINES General § 91.6 Reference materials. (a) Incorporation by... the Research Method Appendix A to Subpart D. ASTM D2700-92: Standard Test Method for Knock... 40 CFR part 91 reference SAE J1228/ISO 8665 November 1991 Small Craft-Marine Propulsion Engine and...

  20. 40 CFR 91.6 - Reference materials.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... EMISSIONS FROM MARINE SPARK-IGNITION ENGINES General § 91.6 Reference materials. (a) Incorporation by... the Research Method Appendix A to Subpart D. ASTM D2700-92: Standard Test Method for Knock... 40 CFR part 91 reference SAE J1228/ISO 8665 November 1991 Small Craft-Marine Propulsion Engine and...

  1. Certification of elements in and use of standard reference material 3280 multivitamin/multielement tablets

    USDA-ARS?s Scientific Manuscript database

    Standard Reference Material (SRM) 3280 Multivitamin/Multielement Tablets was issued by the National Institute of Standards and Technology (NIST) in 2009 and has certified and reference mass fraction values for 13 vitamins, 26 elements, and 2 carotenoids. Elements were measured using two or more ana...

  2. Teaching about Asia: Professional Materials and Reference Books.

    ERIC Educational Resources Information Center

    Hantula, James N.

    This two-part document serves as a guide to basic materials on Asia. The first part provides the teacher of Asian studies with nonserial examples of pertinent professional materials and reference books in print since 1979. Criteria used in selecting the items are given and a brief comparison between materials available in 1969 and 1985 is made.…

  3. 40 CFR 1060.810 - What materials does this part reference?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    .... (a) ASTM material. Table 1 to this section lists material from the American Society for Testing and..., West Conshohocken, PA 19428 or http://www.astm.com. Table 1 follows: Table 1 to § 1060.810—ASTM Materials Document number and name Part 1060reference ASTM D471-06, Standard Test Method for Rubber Property...

  4. Biscayne aquifer drinking water (USGS45): a new isotopic reference material for δ2H and δ18O measurements of water.

    PubMed

    Lorenz, Jennifer M; Tarbox, Lauren; Buck, Bryan; Qi, Haiping; Coplen, Tyler B

    2014-10-15

    As a result of the scarcity of isotopic reference waters for daily use, a new secondary isotopic reference material for international distribution has been prepared from drinking water collected from the Biscayne aquifer in Ft. Lauderdale, Florida. This isotopic reference water was filtered, homogenized, loaded into glass ampoules, sealed with a torch, autoclaved to eliminate biological activity, and measured by dual-inlet isotope-ratio mass spectrometry. This reference material is available by the case of 144 glass ampoules containing either 4 mL or 5 mL of water in each ampoule. The δ(2)H and δ(18)O values of this reference material are -10.3 ± 0.4‰ and -2.238 ± 0.011‰, respectively, relative to VSMOW, on scales normalized such that the δ(2)H and δ(18)O values of SLAP reference water are, respectively, -428 and -55.5‰. Each uncertainty is an estimated expanded uncertainty (U = 2uc ) about the reference value that provides an interval that has about a 95% probability of encompassing the true value. This isotopic reference material, designated as USGS45, is intended as one of two isotopic reference waters for daily normalization of stable hydrogen and oxygen isotopic analysis of water with an isotope-ratio mass spectrometer or a laser absorption spectrometer. Published in 2014. This article is a U.S. Government work and is in the public domain in the USA. Published in 2014. This article is a U.S. Government work and is in the public domain in the USA.

  5. Critical outlook and trends for environmental reference materials at the Measurements & Testing Generic Activity (European Commission).

    PubMed

    Quevauviller, P; Bennink, D; Bøwadt, S

    2001-05-01

    It is now well recognised that the quality control (QC) of all types of analyses, including environmental analyses depends on the appropriate use of reference materials. One of the ways to check the accuracy of methods is based on the use of Certified Reference Materials (CRMs), whereas other types of (not certified) Reference Materials (RMs) are used for routine quality control (establishment of control charts) and interlaboratory testing (e.g. proficiency testing). The perception of these materials, in particular with respect to their production and use, differs widely according to various perspectives (e.g. RM producers, routine laboratories, researchers). This review discusses some critical aspects of RM use and production for the QC of environmental analyses and describes the new approach followed by the Measurements & Testing Generic Activity (European Commission) to tackle new research and production needs.

  6. A new basaltic glass microanalytical reference material for multiple techniques

    USGS Publications Warehouse

    Wilson, Steve; Koenig, Alan; Lowers, Heather

    2012-01-01

    The U.S. Geological Survey (USGS) has been producing reference materials since the 1950s. Over 50 materials have been developed to cover bulk rock, sediment, and soils for the geological community. These materials are used globally in geochemistry, environmental, and analytical laboratories that perform bulk chemistry and/or microanalysis for instrument calibration and quality assurance testing. To answer the growing demand for higher spatial resolution and sensitivity, there is a need to create a new generation of microanalytical reference materials suitable for a variety of techniques, such as scanning electron microscopy/X-ray spectrometry (SEM/EDS), electron probe microanalysis (EPMA), laser ablation inductively coupled mass spectrometry (LA-ICP-MS), and secondary ion mass spectrometry (SIMS). As such, the microanalytical reference material (MRM) needs to be stable under the beam, be homogeneous at scales of better than 10–25 micrometers for the major to ultra-trace element level, and contain all of the analytes (elements or isotopes) of interest. Previous development of basaltic glasses intended for LA-ICP-MS has resulted in a synthetic basaltic matrix series of glasses (USGS GS-series) and a natural basalt series of glasses (BCR-1G, BHVO-2G, and NKT-1G). These materials have been useful for the LA-ICP-MS community but were not originally intended for use by the electron or ion beam community. A material developed from start to finish with intended use in multiple microanalytical instruments would be useful for inter-laboratory and inter-instrument platform comparisons. This article summarizes the experiments undertaken to produce a basalt glass reference material suitable for distribution as a multiple-technique round robin material. The goal of the analytical work presented here is to demonstrate that the elemental homogeneity of the new glass is acceptable for its use as a reference material. Because the round robin exercise is still underway, only nominal compositional ranges for each element are given in the article.

  7. Compatibility of Elastomeric Seal Compounds with MIL-H-6083 and MIL-H- 46170 Hydraulic Fluid

    DTIC Science & Technology

    1990-06-01

    are also made with results obtained using NBR -L, a reference material cited in AMS 3217. 20. DISTRIBUTION/AVAILABILJTY OF ABSTRACT 21. ABSTRACT...Concurrent comparative studies were conducted using NBR -L, a standard reference compound cited in Aerospace Materials Specification (AMS) 3217. Volume...of a standard reference material such as NBR -L, cited in AMS 3217. Obviously, requirements for fluids and for seals are both dictated by the needs of

  8. Field Demonstration and Validation of a New Device for Measuring Water and Solute Fluxes at CFB Borden

    DTIC Science & Technology

    2006-11-01

    All Quality Control Reference Materials are acquired only from authorized vendors or sources commonly used by U.S. EPA Regional Laboratories...Institue of Standards and Testing (NITS) Standard Reference Materials (SRM) or to the U.S. EPA Reference Standards. Working Standards The commercial...contaminants from clothing or equipment by blowing, shaking or any other means that may disperse material into the air is prohibited. 7.1.3. All disposable

  9. Homogeneity study of a corn flour laboratory reference material candidate for inorganic analysis.

    PubMed

    Dos Santos, Ana Maria Pinto; Dos Santos, Liz Oliveira; Brandao, Geovani Cardoso; Leao, Danilo Junqueira; Bernedo, Alfredo Victor Bellido; Lopes, Ricardo Tadeu; Lemos, Valfredo Azevedo

    2015-07-01

    In this work, a homogeneity study of a corn flour reference material candidate for inorganic analysis is presented. Seven kilograms of corn flour were used to prepare the material, which was distributed among 100 bottles. The elements Ca, K, Mg, P, Zn, Cu, Fe, Mn and Mo were quantified by inductively coupled plasma optical emission spectrometry (ICP OES) after acid digestion procedure. The method accuracy was confirmed by analyzing the rice flour certified reference material, NIST 1568a. All results were evaluated by analysis of variance (ANOVA) and principal component analysis (PCA). In the study, a sample mass of 400mg was established as the minimum mass required for analysis, according to the PCA. The between-bottle test was performed by analyzing 9 bottles of the material. Subsamples of a single bottle were analyzed for the within-bottle test. No significant differences were observed for the results obtained through the application of both statistical methods. This fact demonstrates that the material is homogeneous for use as a laboratory reference material. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Interlaboratory comparison of reference materials for nitrogen-isotope-ratio measurements

    USGS Publications Warehouse

    Böhlke, John Karl; Coplen, Tyler B.

    1995-01-01

    Aliquots of seven different reference materials were distributed for an interlaboratory comparison of stable nitrogen-isotope-ratio measurements. Results from 15 laboratories were compiled and evaluated selectively to yield provisional values of 515N for each material, i, with respect to atmospheric N2 (o1SN,7air). The 515N values reported by the different laboratories are correlated in such a way that some of the major discrepancies may be removed by normalization (/. e., by altering the length of the ô N scale for each laboratory by an amount defined by local measurements of reference materials with extreme values).

  11. ALT-114 and ALT-118 Alternative Approaches to NIST ...

    EPA Pesticide Factsheets

    In 2016, US EPA approved two separate alternatives (ALT 114 and ALT 118) for the preparation and certification of Hydrogen Chloride (HCl) and Mercury (Hg) cylinder reference gas standards that can serve as EPA Protocol gases where EPA Protocol are required, but unavailable. The alternatives were necessary due to the unavailability of NIST reference materials (SRM, NTRM, CRM or RGM) or VSL reference materials (VSL PRM or VSL CRM), reference materials identified in EPA’s Green Book as necessary to establish the traceability of EPA protocol gases. ALT 114 and ALT 118 provides a pathway for gas vendors to prepare and certify traceable gas cylinder standards for use in certifying Hg and HCl CEMS. In this presentation, EPA will describe the mechanics and requirements of the performance-based approach, provide an update on the availability of these gas standards and also discuss the potential for producing and certifying gas standards for other compounds using this approach. This presentation discusses the importance of NIST-traceable reference gases relative to regulatory source compliance emissions monitoring. Specifically this presentation discusses 2 new approaches for making necessary reference gases available in the absence of NIST reference materials. Moreover, these approaches provide an alternative approach to rapidly make available new reference gases for additional HAPS regulatory compliance emissions measurement and monitoring.

  12. Development of a reference material of a single DNA molecule for the quality control of PCR testing.

    PubMed

    Mano, Junichi; Hatano, Shuko; Futo, Satoshi; Yoshii, Junji; Nakae, Hiroki; Naito, Shigehiro; Takabatake, Reona; Kitta, Kazumi

    2014-09-02

    We developed a reference material of a single DNA molecule with a specific nucleotide sequence. The double-strand linear DNA which has PCR target sequences at the both ends was prepared as a reference DNA molecule, and we named the PCR targets on each side as confirmation sequence and standard sequence. The highly diluted solution of the reference molecule was dispensed into 96 wells of a plastic PCR plate to make the average number of molecules in a well below one. Subsequently, the presence or absence of the reference molecule in each well was checked by real-time PCR targeting for the confirmation sequence. After an enzymatic treatment of the reaction mixture in the positive wells for the digestion of PCR products, the resultant solution was used as the reference material of a single DNA molecule with the standard sequence. PCR analyses revealed that the prepared samples included only one reference molecule with high probability. The single-molecule reference material developed in this study will be useful for the absolute evaluation of a detection limit of PCR-based testing methods, the quality control of PCR analyses, performance evaluations of PCR reagents and instruments, and the preparation of an accurate calibration curve for real-time PCR quantitation.

  13. Fraud Education for Accounting Students.

    ERIC Educational Resources Information Center

    Peterson, Bonita K.

    2003-01-01

    Reports that limited fraud education takes place in accounting due to a crowded curriculum and misunderstanding of the extent of fraud. Suggests ways to develop content on the topic and provides a list of teaching materials (textbooks, workbooks, trade books, case materials, videos, and reference materials). (Contains 16 references.) (SK)

  14. Acoustic imaging microscope

    DOEpatents

    Deason, Vance A.; Telschow, Kenneth L.

    2006-10-17

    An imaging system includes: an object wavefront source and an optical microscope objective all positioned to direct an object wavefront onto an area of a vibrating subject surface encompassed by a field of view of the microscope objective, and to direct a modulated object wavefront reflected from the encompassed surface area through a photorefractive material; and a reference wavefront source and at least one phase modulator all positioned to direct a reference wavefront through the phase modulator and to direct a modulated reference wavefront from the phase modulator through the photorefractive material to interfere with the modulated object wavefront. The photorefractive material has a composition and a position such that interference of the modulated object wavefront and modulated reference wavefront occurs within the photorefractive material, providing a full-field, real-time image signal of the encompassed surface area.

  15. Measuring Thermal Conductivity at LH2 Temperatures

    NASA Technical Reports Server (NTRS)

    Selvidge, Shawn; Watwood, Michael C.

    2004-01-01

    For many years, the National Institute of Standards and Technology (NIST) produced reference materials for materials testing. One such reference material was intended for use with a guarded hot plate apparatus designed to meet the requirements of ASTM C177-97, "Standard Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded-Hot-Plate Apparatus." This apparatus can be used to test materials in various gaseous environments from atmospheric pressure to a vacuum. It allows the thermal transmission properties of insulating materials to be measured from just above ambient temperature down to temperatures below liquid hydrogen. However, NIST did not generate data below 77 K temperature for the reference material in question. This paper describes a test method used at NASA's Marshall Space Flight Center (MSFC) to optimize thermal conductivity measurements during the development of thermal protection systems. The test method extends the usability range of this reference material by generating data at temperatures lower than 77 K. Information provided by this test is discussed, as are the capabilities of the MSFC Hydrogen Test Facility, where advanced methods for materials testing are routinely developed and optimized in support of aerospace applications.

  16. Toward Worldwide Hepcidin Assay Harmonization: Identification of a Commutable Secondary Reference Material.

    PubMed

    van der Vorm, Lisa N; Hendriks, Jan C M; Laarakkers, Coby M; Klaver, Siem; Armitage, Andrew E; Bamberg, Alison; Geurts-Moespot, Anneke J; Girelli, Domenico; Herkert, Matthias; Itkonen, Outi; Konrad, Robert J; Tomosugi, Naohisa; Westerman, Mark; Bansal, Sukhvinder S; Campostrini, Natascia; Drakesmith, Hal; Fillet, Marianne; Olbina, Gordana; Pasricha, Sant-Rayn; Pitts, Kelly R; Sloan, John H; Tagliaro, Franco; Weykamp, Cas W; Swinkels, Dorine W

    2016-07-01

    Absolute plasma hepcidin concentrations measured by various procedures differ substantially, complicating interpretation of results and rendering reference intervals method dependent. We investigated the degree of equivalence achievable by harmonization and the identification of a commutable secondary reference material to accomplish this goal. We applied technical procedures to achieve harmonization developed by the Consortium for Harmonization of Clinical Laboratory Results. Eleven plasma hepcidin measurement procedures (5 mass spectrometry based and 6 immunochemical based) quantified native individual plasma samples (n = 32) and native plasma pools (n = 8) to assess analytical performance and current and achievable equivalence. In addition, 8 types of candidate reference materials (3 concentrations each, n = 24) were assessed for their suitability, most notably in terms of commutability, to serve as secondary reference material. Absolute hepcidin values and reproducibility (intrameasurement procedure CVs 2.9%-8.7%) differed substantially between measurement procedures, but all were linear and correlated well. The current equivalence (intermeasurement procedure CV 28.6%) between the methods was mainly attributable to differences in calibration and could thus be improved by harmonization with a common calibrator. Linear regression analysis and standardized residuals showed that a candidate reference material consisting of native lyophilized plasma with cryolyoprotectant was commutable for all measurement procedures. Mathematically simulated harmonization with this calibrator resulted in a maximum achievable equivalence of 7.7%. The secondary reference material identified in this study has the potential to substantially improve equivalence between hepcidin measurement procedures and contributes to the establishment of a traceability chain that will ultimately allow standardization of hepcidin measurement results. © 2016 American Association for Clinical Chemistry.

  17. Certification of elements in and use of standard reference material 3280 multivitamin/multielement tablets.

    PubMed

    Turk, Gregory C; Sharpless, Katherine E; Cleveland, Danielle; Jongsma, Candice; Mackey, Elizabeth A; Marlow, Anthony F; Oflaz, Rabia; Paul, Rick L; Sieber, John R; Thompson, Robert Q; Wood, Laura J; Yu, Lee L; Zeisler, Rolf; Wise, Stephen A; Yen, James H; Christopher, Steven J; Day, Russell D; Long, Stephen E; Greene, Ella; Harnly, James; Ho, I-Pin; Betz, Joseph M

    2013-01-01

    Standard Reference Material 3280 Multivitamin/ Multielement Tablets was issued by the National Institute of Standards and Technology in 2009, and has certified and reference mass fraction values for 13 vitamins, 26 elements, and two carotenoids. Elements were measured using two or more analytical methods at NIST with additional data contributed by collaborating laboratories. This reference material is expected to serve a dual purpose: to provide quality assurance in support of a database of dietary supplement products and to provide a means for analysts, dietary supplement manufacturers, and researchers to assess the appropriateness and validity of their analytical methods and the accuracy of their results.

  18. Effect of polyvinylpyrrolidone on mesoporous silica morphology and esterification of lauric acid with 1-butanol catalyzed by immobilized enzyme

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Jinyu; Zhou, Guowei, E-mail: guoweizhou@hotmail.com; Jiang, Bin

    2014-05-01

    Mesoporous silica materials with a range of morphology evolution, i.e., from curved rod-shaped mesoporous silica to straight rod-shaped mesoporous silica, were successfully prepared using polyvinylpyrrolidone (PVP) and triblock copolymer as dual template. The effects of PVP molecular weight and concentration on mesoporous silica structure parameters were studied. Results showed that surface area and pore volume continuously decreased with increased PVP molecular weight. Mesoporous silica prepared with PVP K30 also possessed larger pore diameter, interplanar spacing (d{sub 100}), and cell parameter (a{sub 0}) than that prepared with PVP K15 and PVP K90. In addition, with increased PVP concentration, d{sub 100} andmore » a{sub 0} continuously decreased. The mechanism of morphology evolution caused by the change in PVP concentration was investigated. The conversion rate of lauric acid with 1-butanol catalyzed by immobilized Porcine pancreatic lipase (PPL) was also evaluated. Results showed that PPL immobilized on amino-functionalized straight rod-shaped mesoporous silica maintained 50% of its esterification conversion rate even after five cycles of use with a maximum conversion rate was about 90.15%. - Graphical abstract: Curved rod-shaped mesoporous silica can be obtained at low and the highest PVP concentration, while straight rod-shaped mesoporous silica can be obtained at higher PVP concentration. - Highlights: • Mesoporous silica with morphology evolution from CRMS to SRMS were prepared. • Effects of PVP molecular weight and concentration on silica morphology were studied. • A possible mechanism for the formation of morphology evolution SiO{sub 2} was proposed. • Esterification of lauric acid with 1-butanol catalyzed by immobilized PPL.« less

  19. 40 CFR 92.5 - Reference materials.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...: (1) ASTM material. The following table sets forth material from the American Society for Testing and...., Philadelphia, PA 19103. The table follows: Document number and name 40 CFR part 92 reference ASTM D 86-95, Standard Test Method for Distillation of Petroleum Products § 92.113 ASTM D 93-94, Standard Test Methods...

  20. 40 CFR 1060.810 - What materials does this part reference?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) AIR POLLUTION CONTROLS CONTROL OF EVAPORATIVE EMISSIONS FROM NEW AND IN-USE NONROAD AND STATIONARY... Speciation, December 2003 1060.801 (c) California Air Resources Board material. Table 3 to this section lists material from the California Air Resources Board that we have incorporated by reference. The first column...

  1. 40 CFR 1060.810 - What materials does this part reference?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) AIR POLLUTION CONTROLS CONTROL OF EVAPORATIVE EMISSIONS FROM NEW AND IN-USE NONROAD AND STATIONARY... Speciation, December 2003 1060.801 (c) California Air Resources Board material. Table 3 to this section lists material from the California Air Resources Board that we have incorporated by reference. The first column...

  2. 40 CFR 1060.810 - What materials does this part reference?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) AIR POLLUTION CONTROLS CONTROL OF EVAPORATIVE EMISSIONS FROM NEW AND IN-USE NONROAD AND STATIONARY... Speciation, December 2003 1060.801 (c) California Air Resources Board material. Table 3 to this section lists material from the California Air Resources Board that we have incorporated by reference. The first column...

  3. Military aircraft and missile technology at the Langley Research Center: A selected bibliography

    NASA Technical Reports Server (NTRS)

    Maddalon, D. V.

    1980-01-01

    A compilation of reference material is presented on the Langley Research Center's efforts in developing advanced military aircraft and missile technology over the past twenty years. Reference material includes research made in aerodynamics, performance, stability, control, stall-spin, propulsion integration, flutter, materials, and structures.

  4. Field Demonstration and Validation of a New Device for Measuring Water and Solute Fluxes at Naval Base Ventura County (NBVC), Port Hueneme, CA

    DTIC Science & Technology

    2006-07-01

    All Quality Control Reference Materials are acquired only from authorized vendors or sources commonly used by U.S. EPA Regional Laboratories...are traceable to the National Institue of Standards and Testing (NITS) Standard Reference Materials (SRM) or to the U.S. EPA Reference Standards... clothing or equipment by blowing, shaking or any other means that may disperse material into the air is prohibited. 7.1.3. All disposable personal

  5. Ultra high frequency imaging acoustic microscope

    DOEpatents

    Deason, Vance A.; Telschow, Kenneth L.

    2006-05-23

    An imaging system includes: an object wavefront source and an optical microscope objective all positioned to direct an object wavefront onto an area of a vibrating subject surface encompassed by a field of view of the microscope objective, and to direct a modulated object wavefront reflected from the encompassed surface area through a photorefractive material; and a reference wavefront source and at least one phase modulator all positioned to direct a reference wavefront through the phase modulator and to direct a modulated reference wavefront from the phase modulator through the photorefractive material to interfere with the modulated object wavefront. The photorefractive material has a composition and a position such that interference of the modulated object wavefront and modulated reference wavefront occurs within the photorefractive material, providing a full-field, real-time image signal of the encompassed surface area.

  6. [The water content reference material of water saturated octanol].

    PubMed

    Wang, Haifeng; Ma, Kang; Zhang, Wei; Li, Zhanyuan

    2011-03-01

    The national standards of biofuels specify the technique specification and analytical methods. A water content certified reference material based on the water saturated octanol was developed in order to satisfy the needs of the instrument calibration and the methods validation, assure the accuracy and consistency of results in water content measurements of biofuels. Three analytical methods based on different theories were employed to certify the water content of the reference material, including Karl Fischer coulometric titration, Karl Fischer volumetric titration and quantitative nuclear magnetic resonance. The consistency of coulometric and volumetric titration was achieved through the improvement of methods. The accuracy of the certified result was improved by the introduction of the new method of quantitative nuclear magnetic resonance. Finally, the certified value of reference material is 4.76% with an expanded uncertainty of 0.09%.

  7. Reading Materials in Large Print: A Resource Guide. Reference Circular No. 97-02.

    ERIC Educational Resources Information Center

    Mendle, Gillian, Comp.

    This reference circular contains information about large-print materials. Section 1 is an annotated list of selected sources of large-print materials available for purchase or loan. The sources are publishers or distributors, specialized libraries, and associations for persons with visual impairments. Several of these sources also provide general…

  8. 40 CFR 1060.810 - What materials does this part reference?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., July 26, 2004 1060.105, 1060.240 (d) American Boat and Yacht Council Material. Table 4 to this section lists material from the American Boat and Yacht Council that we have incorporated by reference. The... Yacht Council, 613 Third Street, Suite 10, Annapolis, MD 21403 or http://www.abycinc.org/. Table 4...

  9. Development of candidate reference materials for the measurement of lead in bone

    PubMed Central

    Hetter, Katherine M.; Bellis, David J.; Geraghty, Ciaran; Todd, Andrew C.; Parsons, Patrick J.

    2010-01-01

    The production of modest quantities of candidate bone lead (Pb) reference materials is described, and an optimized production procedure is presented. The reference materials were developed to enable an assessment of the interlaboratory agreement of laboratories measuring Pb in bone; method validation; and for calibration of solid sampling techniques such as laser ablation ICP-MS. Long bones obtained from Pb-dosed and undosed animals were selected to produce four different pools of a candidate powdered bone reference material. The Pb concentrations of these pools reflect both environmental and occupational exposure levels in humans. The animal bones were harvested post mortem, cleaned, defatted, and broken into pieces using the brittle fracture technique at liquid nitrogen temperature. The bone pieces were then ground in a knife mill to produce fragments of 2-mm size. These were further ground in an ultra-centrifugal mill, resulting in finely powdered bone material that was homogenized and then sampled-scooped into vials. Testing for contamination and homogeneity was performed via instrumental methods of analysis. PMID:18421443

  10. Activity measurements of a suite of radionuclides (241Am, 239,240Pu, 238Pu, 238U, 234U, 235U, 232Th, 230Th, 228Th, 228Ra, 137Cs, 210Pb, 90Sr and 40K) in biota reference material (Ocean Shellfish): CCRI(II)-S3

    NASA Astrophysics Data System (ADS)

    Nour, S.; Karam, L. R.; Inn, K. G. W.

    2012-01-01

    In 2005, the CCRI decided that a comparison undertaken from 2002 to 2008 by the NIST (under the auspices of the Inter-America Metrology System [SIM]) in the development of a new biota (Ocean Shellfish) standard reference material (SRM) was sufficiently well constructed that it could be converted into a supplementary comparison under CCRI(II), with comparison identifier CCRI(II)-S3. This would enable the comparison to be used to support calibration and measurement capability (CMC) claims for radionuclide measurements in reference materials (specifically, animal-based organic materials). Previous comparisons of radionuclides have been of single or multiple nuclides in non-complex matrices and results of such could not be extended to support capabilities to measure the same nuclides in reference materials. The results of this comparison have been used to determine the certified reference value of the SRM. The key comparison working group (KCWG) of the CCRI(II) has approved this approach as a mechanism to link all the results to certified 'reference values' in lieu of the key comparison reference value (KCRV) of these specified radionuclides in this type of matrix (shellfish) so as to support CMCs of similar materials submitted by the present participants. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  11. 40 CFR 90.7 - Reference materials.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS General § 90.7 Reference materials... Fuels by the Research Method Appendix A to subpart D, Table 3. ASTM D2700-92: Standard Test Method for...

  12. 40 CFR 90.7 - Reference materials.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS General § 90.7 Reference materials... Fuels by the Research Method Appendix A to subpart D, Table 3. ASTM D2700-92: Standard Test Method for...

  13. 40 CFR 90.7 - Reference materials.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS General § 90.7 Reference materials... Fuels by the Research Method Appendix A to subpart D, Table 3. ASTM D2700-92: Standard Test Method for...

  14. Evaluation of the 34S/32S ratio of Soufre de Lacq elemental sulfur isotopic reference material by continuous flow isotope-ratio mass spectrometry

    USGS Publications Warehouse

    Qi, H.P.; Coplen, T.B.

    2003-01-01

    Soufre de Lacq elemental sulfur reference material (IAEA-S-4) isotopically is homogeneous in amounts as small as 41 ??g as determined by continuous flow isotope-ratio mass spectrometry. The ??34S value for this reference material is +16.90 ?? 0.12??? (1??) on a scale (Vienna Can??on Diablo troilite, VCDT) where IAEA-S-1 Ag2S is -0.3??? and IAEA-S-2 Ag2S is +22.67???. Published by Elsevier Science B.V.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koponen, Kati; Soimakallio, Sampo; Kline, Keith L.

    In order to understand the climate effects of a bioenergy system, a comparison between the bioenergy system and a reference system is required. The reference system describes the situation that occurs in the absence of the bioenergy system with respect to the use of land, energy, and materials. The importance of reference systems is discussed in the literature but guidance on choosing suitable reference systems for assessing climate effects of bioenergy is limited. The reference system should align with the purpose of the study. Transparency of reference system assumptions is essential for proper interpretation of bioenergy assessments. This paper presentsmore » guidance for selecting suitable reference systems. Particular attention is given to choosing the land reference. If the goal is to study the climate effects of bioenergy as a part of total anthropogenic activity the reference system should illustrate what is expected in the absence of human activities. In such a case the suitable land reference is natural regeneration, and energy or material reference systems are not relevant. If the goal is to assess the effect of a change in bioenergy use, the reference system should incorporate human activities. In this case suitable reference systems describe the most likely alternative uses of the land, energy and materials in the absence of the change in bioenergy use. The definition of the reference system is furthermore subject to the temporal scope of the study. In practice, selecting and characterizing reference systems will involve various choices and uncertainties which should be considered carefully. As a result, it can be instructive to consider how alternative reference systems influence the results and conclusions drawn from bioenergy assessments.« less

  16. Analytical Bias Exceeding Desirable Quality Goal in 4 out of 5 Common Immunoassays: Results of a Native Single Serum Sample External Quality Assessment Program for Cobalamin, Folate, Ferritin, Thyroid-Stimulating Hormone, and Free T4 Analyses.

    PubMed

    Kristensen, Gunn B B; Rustad, Pål; Berg, Jens P; Aakre, Kristin M

    2016-09-01

    We undertook this study to evaluate method differences for 5 components analyzed by immunoassays, to explore whether the use of method-dependent reference intervals may compensate for method differences, and to investigate commutability of external quality assessment (EQA) materials. Twenty fresh native single serum samples, a fresh native serum pool, Nordic Federation of Clinical Chemistry Reference Serum X (serum X) (serum pool), and 2 EQA materials were sent to 38 laboratories for measurement of cobalamin, folate, ferritin, free T4, and thyroid-stimulating hormone (TSH) by 5 different measurement procedures [Roche Cobas (n = 15), Roche Modular (n = 4), Abbott Architect (n = 8), Beckman Coulter Unicel (n = 2), and Siemens ADVIA Centaur (n = 9)]. The target value for each component was calculated based on the mean of method means or measured by a reference measurement procedure (free T4). Quality specifications were based on biological variation. Local reference intervals were reported from all laboratories. Method differences that exceeded acceptable bias were found for all components except folate. Free T4 differences from the uncommonly used reference measurement procedure were large. Reference intervals differed between measurement procedures but also within 1 measurement procedure. The serum X material was commutable for all components and measurement procedures, whereas the EQA materials were noncommutable in 13 of 50 occasions (5 components, 5 methods, 2 EQA materials). The bias between the measurement procedures was unacceptably large in 4/5 tested components. Traceability to reference materials as claimed by the manufacturers did not lead to acceptable harmonization. Adjustment of reference intervals in accordance with method differences and use of commutable EQA samples are not implemented commonly. © 2016 American Association for Clinical Chemistry.

  17. Selected Bibliography on Culture and Cultural Materials, Preliminary Edition. Series A: Reference Materials, Human Relations in Cultural Context.

    ERIC Educational Resources Information Center

    Condon, E. C.; And Others

    Included in this bibliography are references to resources and materials available to the teacher and educator on human relations and cultural education. The bibliography is divided into three sections on culture, specific culture, and adult bilingual-bicultural education. The section on culture presents background information on the relation of…

  18. River bottom sediment from the Vistula as matrix of candidate for a new reference material.

    PubMed

    Kiełbasa, Anna; Buszewski, Bogusław

    2017-08-01

    Bottom sediments are very important in aquatic ecosystems. The sediments accumulate heavy metals and compounds belonging to the group of persistent organic pollutants. The accelerated solvent extraction (ASE) was used for extraction of 16 compounds from PAH group from bottom sediment of Vistula. For the matrix of candidate of a new reference material, moisture content, particle size, loss on ignition, pH, and total organic carbon were determined. A gas chromatograph with a selective mass detector (GC/MS) was used for the final analysis. The obtained recoveries were from 86% (SD=6.9) for anthracene to 119% (SD=5.4) for dibenzo(ah)anthracene. For the candidate for a new reference material, homogeneity and analytes content were determined using a validated method. The results are a very important part of the development and certification of a new reference materials. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Certification of reference materials for the determination of alkylphenols.

    PubMed

    Hanari, Nobuyasu; Ishikawa, Keiichiro; Shimizu, Yoshitaka; Otsuka, Satoko; Iwasawa, Ryoko; Fujiki, Naomi; Numata, Masahiko; Yarita, Takashi; Kato, Kenji

    2015-04-01

    Certified reference materials (CRMs) are playing an increasingly important role in national and international standardizing activities. In Japan, primary standard solutions for analyses of endocrine disrupters are supplied under the national standards dissemination system named the Japan Calibration Service System (JCSS). For the traceability on reference materials used for preparation of the primary standard solutions based on the JCSS, the National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology (NMIJ/AIST) has developed and certified high-purity reference materials of alkylphenols as NMIJ CRMs, such as 4-n-nonylphenol, 4-tert-octylphenol, 4-n-heptylphenol, 4-tert-butylphenol, and 2,4-dichlorophenol. Thereafter, it is essential to determine the alkylphenols by using these solutions based on the JCSS for environmental monitoring and risk assessments because analytical values obtained by using the solutions can ensure the reliability and traceability of the chemical analyses.

  20. A feasibility study for producing an egg matrix candidate reference material for the polyether ionophore salinomycin.

    PubMed

    Ferreira, Rosana Gomes; Monteiro, Mychelle Alves; Pereira, Mararlene Ulberg; da Costa, Rafaela Pinto; Spisso, Bernardete Ferraz; Calado, Veronica

    2016-08-01

    The aim of this work was to study the feasibility of producing an egg matrix candidate reference material for salinomycin. Preservation techniques investigated were freeze-drying and spray drying dehydration. Homogeneity and stability studies of the produced batches were conducted according to ISO Guides 34 and 35. The results showed that all produced batches were homogeneous and both freeze-drying and spray drying techniques were suitable for matrix dehydrating, ensuring the material stability. In order to preserve the material integrity, it must be transported within the temperature range of -20 up to 25°C. The results constitute an important step towards the development of an egg matrix reference material for salinomycin is possible. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Evaluation of accuracy of complete-arch multiple-unit abutment-level dental implant impressions using different impression and splinting materials.

    PubMed

    Buzayan, Muaiyed; Baig, Mirza Rustum; Yunus, Norsiah

    2013-01-01

    This in vitro study evaluated the accuracy of multiple-unit dental implant casts obtained from splinted or nonsplinted direct impression techniques using various splinting materials by comparing the casts to the reference models. The effect of two different impression materials on the accuracy of the implant casts was also evaluated for abutment-level impressions. A reference model with six internal-connection implant replicas placed in the completely edentulous mandibular arch and connected to multi-base abutments was fabricated from heat-curing acrylic resin. Forty impressions of the reference model were made, 20 each with polyether (PE) and polyvinylsiloxane (PVS) impression materials using the open tray technique. The PE and PVS groups were further subdivided into four subgroups of five each on the bases of splinting type: no splinting, bite registration PE, bite registration addition silicone, or autopolymerizing acrylic resin. The positional accuracy of the implant replica heads was measured on the poured casts using a coordinate measuring machine to assess linear differences in interimplant distances in all three axes. The collected data (linear and three-dimensional [3D] displacement values) were compared with the measurements calculated on the reference resin model and analyzed with nonparametric tests (Kruskal-Wallis and Mann-Whitney). No significant differences were found between the various splinting groups for both PE and PVS impression materials in terms of linear and 3D distortions. However, small but significant differences were found between the two impression materials (PVS, 91 μm; PE, 103 μm) in terms of 3D discrepancies, irrespective of the splinting technique employed. Casts obtained from both impression materials exhibited differences from the reference model. The impression material influenced impression inaccuracy more than the splinting material for multiple-unit abutment-level impressions.

  2. Certified reference materials for testing of the presence/absence of Staphylococcus aureus enterotoxin A (SEA) in cheese.

    PubMed

    Zeleny, Reinhard; Nia, Yacine; Schimmel, Heinz; Mutel, Isabelle; Hennekinne, Jacques-Antoine; Emteborg, Håkan; Charoud-Got, Jean; Auvray, Frédéric

    2016-08-01

    Staphylococcal enterotoxins (SEs) account for a substantial number of food-poisoning outbreaks. European legislation (Commission Regulation 1441/2007) stipulates the reference procedure for SE analysis in milk and dairy products, which is based on extraction, dialysis concentration and immunochemical detection using one of two approved assays (VIDAS(®) SET2, Ridascreen(®) SET Total). However, certified reference materials (CRMs) are lacking to support laboratories in performing reliable detection of Staphylococcus aureus enterotoxin A (SEA) in relevant matrices at sub-nanogram per gram levels. The certification of a set of three reference materials (blank and two SEA-containing materials) for testing of the presence/absence of SEA in cheese is described. The reference procedure was applied in an intercomparison with 15 laboratories, and results were reported in a qualitative manner (presence or absence of SEA in the sample). No false-negative or false-positive results were obtained. The certified values were stated as diagnostic specificity (blank material) or diagnostic sensitivity (SEA-containing materials) and were 100 % in all cases. Stability studies demonstrated suitable material stability when stored cooled or frozen. An in-house study on the recovery of SEA in the cheese materials using a double-sandwich enzyme-linked immunosorbent assay (ELISA) revealed comparable recovery values of around 45 % at the two spiking levels and in both the SEA-containing CRMs as well as blank CRM freshly spiked prior to analysis. The values were also comparable over time and among different analysts. The materials provide valuable support to laboratories for method validation and method performance verification and will increase the reliability of measuring SEA in cheese.

  3. [The Eastern Quebec telepathology network: a real collective project].

    PubMed

    Têtu, Bernard; Boulanger, Jean; Houde, Christine; Fortin, Jean-Paul; Gagnon, Marie-Pierre; Roch, Geneviève; Paré, Guy; Trudel, Marie-Claude; Sicotte, Claude

    2012-11-01

    The aim of the Eastern Québec telepathology network is to provide uniform diagnostic telepathology services across a huge geographic region with a low population density. This project is intended to provide surgeons and pathologists with frozen section and second opinion services anywhere and at any time across the entire region, in order to avoid unnecessary patient transfer. The project has been implemented in 21 sites, each equipped with a whole slide scanner, a macroscopy station, a videoconferencing device and a viewer/case management and collaboration solution. Of the 21 sites, 6 are devoid of a pathology laboratory, two have no pathologist and 5 have only one pathologist on site. Signs of improvement of medical care in this region are already apparent since the Eastern Québec telepathology network has been implemented. However, it is important not to underestimate the challenges related to change management in the course of implementation of such a new technology. © 2012 médecine/sciences – Inserm / SRMS.

  4. KSC-2014-2139

    NASA Image and Video Library

    2014-04-11

    VANDENBERG AIR FORCE BASE, Calif. – A worker attaches a solid rocket motor, or SRM, for NASA's Orbiting Carbon Observatory-2 mission, or OCO-2, to the Delta II first stage in the mobile service tower at Space Launch Complex 2 on Vandenberg Air Force Base in California. Operations are underway to attach the rocket's three SRMs, known as graphite epoxy motors, to its first stage. OCO-2 is scheduled to launch into a polar Earth orbit aboard a United Launch Alliance Delta II 7320-10C rocket in July. Once in orbit, OCO-2 will collect precise global measurements of carbon dioxide in the Earth's atmosphere and provide scientists with a better idea of the chemical compound's impacts on climate change. Scientists will analyze this data to improve our understanding of the natural processes and human activities that regulate the abundance and distribution of this important atmospheric gas. To learn more about OCO-2, visit http://oco.jpl.nasa.gov. Photo credit: NASA/Randy Beaudoin

  5. KSC-2014-2142

    NASA Image and Video Library

    2014-04-11

    VANDENBERG AIR FORCE BASE, Calif. – The first solid rocket motor, or SRM, for NASA's Orbiting Carbon Observatory-2 mission, or OCO-2, has been attached to the Delta II first stage in the mobile service tower at Space Launch Complex 2 on Vandenberg Air Force Base in California. Operations are underway to attach the rocket's three SRMs, known as graphite epoxy motors, to its first stage. OCO-2 is scheduled to launch into a polar Earth orbit aboard a United Launch Alliance Delta II 7320-10C rocket in July. Once in orbit, OCO-2 will collect precise global measurements of carbon dioxide in the Earth's atmosphere and provide scientists with a better idea of the chemical compound's impacts on climate change. Scientists will analyze this data to improve our understanding of the natural processes and human activities that regulate the abundance and distribution of this important atmospheric gas. To learn more about OCO-2, visit http://oco.jpl.nasa.gov. Photo credit: NASA/Randy Beaudoin

  6. KSC-2014-2131

    NASA Image and Video Library

    2014-04-11

    VANDENBERG AIR FORCE BASE, Calif. – A crane lifts the solid rocket motor, or SRM, for NASA's Orbiting Carbon Observatory-2 mission, or OCO-2, following its delivery to the mobile service tower at Space Launch Complex 2 on Vandenberg Air Force Base in California. Operations are underway to attach the Delta II rocket's three SRMs, known as graphite epoxy motors, to the rocket's first stage. OCO-2 is scheduled to launch into a polar Earth orbit aboard a United Launch Alliance Delta II 7320-10C rocket in July. Once in orbit, OCO-2 will collect precise global measurements of carbon dioxide in the Earth's atmosphere and provide scientists with a better idea of the chemical compound's impacts on climate change. Scientists will analyze this data to improve our understanding of the natural processes and human activities that regulate the abundance and distribution of this important atmospheric gas. To learn more about OCO-2, visit http://oco.jpl.nasa.gov. Photo credit: NASA/Randy Beaudoin

  7. KSC-2014-2134

    NASA Image and Video Library

    2014-04-11

    VANDENBERG AIR FORCE BASE, Calif. – A worker inspects the solid rocket motor, or SRM, for NASA's Orbiting Carbon Observatory-2 mission, or OCO-2, after it is lifted into a vertical position beside the mobile service tower at Space Launch Complex 2 on Vandenberg Air Force Base in California. Operations are underway to attach the Delta II rocket's three SRMs, known as graphite epoxy motors, to the rocket's first stage. OCO-2 is scheduled to launch into a polar Earth orbit aboard a United Launch Alliance Delta II 7320-10C rocket in July. Once in orbit, OCO-2 will collect precise global measurements of carbon dioxide in the Earth's atmosphere and provide scientists with a better idea of the chemical compound's impacts on climate change. Scientists will analyze this data to improve our understanding of the natural processes and human activities that regulate the abundance and distribution of this important atmospheric gas. To learn more about OCO-2, visit http://oco.jpl.nasa.gov. Photo credit: NASA/Randy Beaudoin

  8. Virtual Levels and Role Models: N-Level Structural Equations Model of Reciprocal Ratings Data.

    PubMed

    Mehta, Paras D

    2018-01-01

    A general latent variable modeling framework called n-Level Structural Equations Modeling (NL-SEM) for dependent data-structures is introduced. NL-SEM is applicable to a wide range of complex multilevel data-structures (e.g., cross-classified, switching membership, etc.). Reciprocal dyadic ratings obtained in round-robin design involve complex set of dependencies that cannot be modeled within Multilevel Modeling (MLM) or Structural Equations Modeling (SEM) frameworks. The Social Relations Model (SRM) for round robin data is used as an example to illustrate key aspects of the NL-SEM framework. NL-SEM introduces novel constructs such as 'virtual levels' that allows a natural specification of latent variable SRMs. An empirical application of an explanatory SRM for personality using xxM, a software package implementing NL-SEM is presented. Results show that person perceptions are an integral aspect of personality. Methodological implications of NL-SEM for the analyses of an emerging class of contextual- and relational-SEMs are discussed.

  9. [Rabies].

    PubMed

    Ribadeau-Dumas, Florence; Dacheux, Laurent; Bourhy, Hervé

    2013-01-01

    Rabies virus, a neurotropic lyssavirus responsible for unavoidable fatal encephalitis, is transmitted by saliva of infected animals through bite, scratch or licking of broken skin or a mucous membrane. Infection can be prevented by timely prevention (wash for several minutes, antisepsis and vaccination completed by antirabies immunoglobulins [Ig] according to the severity of exposure). The 55,000 human deaths estimated annually worldwide result mainly from uncontrolled canine rabies in enzootic countries (particularly in Africa and in Asia), attributable to a lack of resources or interest for this disease. Bat rabies, henceforth first cause of human's rabies in many countries in America, affects a very small number of individuals but seems more difficult to control. Shortened vaccine protocols, rationalized use of Ig and development of products of substitution should enhance access of exposed patients to prevention. Finally, research on the biological cycle, the pathogeny and on escape of virus-induced mechanisms from the immune system should continue to pave the way for presently unknown treatments of clinical rabies. © 2013 médecine/sciences – Inserm / SRMS.

  10. [Mice are not Men and yet… how humanized mice inform us about human infectious diseases].

    PubMed

    Cachat, Anne; Villaudy, Julien; Rigal, Dominique; Gazzolo, Louis; Duc Dodon, Madeleine

    2012-01-01

    The study of human pathologies is often limited by the absence of animal models which are robust, cost-effective and reproduce the hallmarks of human infections. While mice have been frequently employed to study human diseases, many of important pathogens display unique human tropism. These last two decades the graft of human progenitor cells or tissues into -immunodeficient mice has allowed the elaboration of so called humanized mice. Humanized mouse technology has made rapid progress, and it is now possible to achieve high levels of human chimerism in various organs and tissues, particularly the immune system and the liver. The review briefly summarizes the different models of humanized mice available for in vivo experiments. With a focus on lymphotropic, monocytotropic and hepatotropic viruses, we here discuss the current status and future prospects of these models for studying the pathogenesis of infectious diseases. Furthermore, they provide a powerful tool for the development of innovative therapies. © 2012 médecine/sciences – Inserm / SRMS.

  11. [RXR, a key member of the oncogenic complex in acute promyelocytic leukemia].

    PubMed

    Halftermeyer, Juliane; Le Bras, Morgane; De Thé, Hugues

    2011-11-01

    Acute promyelocytic leukaemia (APL) is induced by fusion proteins always implying the retinoic acid receptor RARa. Although PML-RARa and other fusion oncoproteins are able to bind DNA as homodimers, in vivo they are always found in association with the nuclear receptor RXRa (Retinoid X Receptor). Thus, RXRa is an essential cofactor of the fusion protein for the transformation. Actually, RXRa contributes to several aspects of in vivo -transformation: RARa fusion:RXRa hetero-oligomeric complexes bind DNA with a much greater affinity than RARa fusion homodimers. Besides, PML-RARa:RXRa recognizes an enlarged repertoire of DNA binding sites. Thus the association between fusion proteins and RXRa regulates more genes than the homodimer alone. Titration of RXRa by the fusion protein may also play a role in the transformation process, as well as post-translational modifications of RXRa in the complex. Finally, RXRa is required for rexinoid-induced APL differentiation. Thus, RXRa is a key member of the oncogenic complex. © 2011 médecine/sciences – Inserm / SRMS.

  12. Quality Control of Next-generation Sequencing-based In vitro Diagnostic Test for Onco-relevant Mutations Using Multiplex Reference Materials in Plasma.

    PubMed

    Liu, Donglai; Zhou, Haiwei; Shi, Dawei; Shen, Shu; Tian, Yabin; Wang, Lin; Lou, Jiatao; Cong, Rong; Lu, Juan; Zhang, Henghui; Zhao, Meiru; Zhu, Shida; Cao, Zhisheng; Jin, Ruilin; Wang, Yin; Zhang, Xiaoni; Yang, Guohua; Wang, Youchun; Zhang, Chuntao

    2018-01-01

    Background: Widespread clinical implementation of next-generation sequencing (NGS)-based cancer in vitro diagnostic tests (IVDs) highlighted the urgency to establish reference materials which could provide full control of the process from nucleic acid extraction to test report generation. The formalin-fixed, paraffin-embedded (FFPE) tissue and blood plasma containing circulating tumor deoxyribonucleic acid (ctDNA) were mostly used for clinically detecting onco-relevant mutations. Methods: We respectively developed multiplex FFPE and plasma reference materials covering three clinically onco-relevant mutations within the epidermal growth factor receptor ( EGFR ) gene at serial allelic frequencies. All reference materials were quantified and validated via droplet digital polymerase chain reaction (ddPCR), and then were distributed to eight domestic manufacturers for the collaborative evaluation of the performance of several domestic NGS-based cancer IVDs covering four major NGS platforms (NextSeq, HiSeq, Ion Proton and BGISEQ). Results: All expected mutations except one at extremely low allelic frequencies were detected, despite some differences in coefficient of variation (CV) which increased with the decrease of allelic frequency (CVs ranging from 18% to 106%). It was worth noting that the CV value seemed to correlate with a particular mutation as well. The repeatability of determination of different mutations was L858R>T790M>19del. Conclusions: The results indicated our reference materials would be pivotal for quality control of NGS-based cancer IVDs and would guide the further development of reference materials covering more onco-relevant mutations.

  13. Development of certified reference materials for electrolytes in human serum (GBW09124-09126).

    PubMed

    Feng, Liuxing; Wang, Jun; Cui, Yanjie; Shi, Naijie; Li, Haifeng; Li, Hongmei

    2017-05-01

    Three reference materials, at relatively low, middle, and high concentrations, were developed for analysis of the mass fractions of electrolytes (K, Ca, Na, Mg, Cl, and Li) in human serum. The reference materials were prepared by adding high purity chloride salts to normal human serum. The concentration range of the three levels is within ±20% of normal human serum. It was shown that 14 units with duplicate analysis is enough to demonstrate the homogeneity of these candidate reference materials. The statistical results also showed no significant trends in both short-term stability test for 1 week at 40 °C and long-term stability test for 14 months. The certification methods of the six elements include isotope dilution inductively coupled plasma mass spectrometry (ID-ICP-MS), inductively coupled plasma optical emission spectroscopy (ICP-OES), atomic absorption spectroscopy (AAS), ion chromatography (IC), and ion-selective electrode (ISE). The certification methods were validated by international comparisons among a number of national metrology institutes (NMIs). The combined relative standard uncertainties of the property values were estimated by considering the uncertainties of the analytical methods, homogeneity, and stability. The range of the expanded uncertainties of all the elements is from 2.2% to 3.9%. The certified reference materials (CRMs) are primarily intended for use in the calibration and validation of procedures in clinical analysis for the determination of electrolytes in human serum or plasma. Graphical Abstract Certified reference materials for K, Ca, Mg, Na, Cl and Li in human serum (GBW09124-09126).

  14. [Comparative research on the NIR and MIR micro-imaging of two similar plastic materials].

    PubMed

    Wang, Dong; Ma, Zhi-Hong; Zhao, Liu; Pan, Li-Gang; Li, Xiao-Ting; Wang, Ji-Hua

    2011-09-01

    The NIR/MIR micro-imaging can supply not only the information of spectra, but also the information of spacial distribution of the sample, which is superior to the traditional NIR/MIR spectroscopy analysis. In the present paper, polyethylene and parafilm, with similar appearances, were regarded as the research objects, of which the NIR/MIR micro-imaging was collected. Chemical imaging (CI) and compare correlation imaging were carried out for the two materials respectively to discuss the imaging methods of the two materials. The result indicated that the differentiation of the CI values of the two materials in the NIR/MIR CI for material II was 0.004 8 and 0.254 8 respectively, while those in the NIR/MIR CI for material I were 0.002 6 and 0.326 5, respectively. Clear CI was acquired, and the two materials could be differentiated. The result of the compare correlation imagings indicated that the compare correlation imagings, in which the NIR/MIR spectra of the two materials were regarded as reference spectra respectively, can differentiate the two materials remarkably with clear imagings. In the compare correlation imagings of MIR micro-imaging, the difference of the correlation coefficients between the two materials' MIR spectra and the reference spectrum was more than 0.12, which showed a better imaging result; while a tiny difference of the correlation coefficients between the two materials' NIR spectra and the reference spectrum could be employed to show a clear imaging result for NIR compare correlation imaging so as to differentiate the two materials. This thesis, to some extent, can supply the reference to not only the rapid discrimination of the safety of the packaging material for agri-food, but also the imaging methods for NIR/MIR micro-imaging to differentiate the different materials.

  15. 49 CFR 572.110 - Materials incorporated by reference.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 7 2014-10-01 2014-10-01 false Materials incorporated by reference. 572.110 Section 572.110 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) ANTHROPOMORPHIC TEST DEVICES Side...

  16. 49 CFR 572.110 - Materials incorporated by reference.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 7 2013-10-01 2013-10-01 false Materials incorporated by reference. 572.110 Section 572.110 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) ANTHROPOMORPHIC TEST DEVICES Side...

  17. 49 CFR 572.110 - Materials incorporated by reference.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 7 2012-10-01 2012-10-01 false Materials incorporated by reference. 572.110 Section 572.110 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) ANTHROPOMORPHIC TEST DEVICES Side...

  18. BIOBASED MATERIALS

    EPA Science Inventory

    Biobased materials refer to products that mainly consist of a substance (or substances) derived from living matter (biomass) and either occur naturally or are synthesized, or it may refer to products made by processes that use biomass. Following a strict definition, many common m...

  19. Quantifying the climate effects of bioenergy – Choice of reference system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koponen, Kati; Soimakallio, Sampo; Kline, Keith L.

    In order to understand the climate effects of a bioenergy system, a comparison between the bioenergy system and a reference system is required. The reference system describes the situation that occurs in the absence of the bioenergy system with respect to the use of land, energy, and materials. The importance of reference systems is discussed in the literature but guidance on choosing suitable reference systems for assessing climate effects of bioenergy is limited. The reference system should align with the purpose of the study. Transparency of reference system assumptions is essential for proper interpretation of bioenergy assessments. This paper presentsmore » guidance for selecting suitable reference systems. Particular attention is given to choosing the land reference. If the goal is to study the climate effects of bioenergy as a part of total anthropogenic activity the reference system should illustrate what is expected in the absence of human activities. In such a case the suitable land reference is natural regeneration, and energy or material reference systems are not relevant. If the goal is to assess the effect of a change in bioenergy use, the reference system should incorporate human activities. In this case suitable reference systems describe the most likely alternative uses of the land, energy and materials in the absence of the change in bioenergy use. The definition of the reference system is furthermore subject to the temporal scope of the study. In practice, selecting and characterizing reference systems will involve various choices and uncertainties which should be considered carefully. As a result, it can be instructive to consider how alternative reference systems influence the results and conclusions drawn from bioenergy assessments.« less

  20. Quantifying the climate effects of bioenergy – Choice of reference system

    DOE PAGES

    Koponen, Kati; Soimakallio, Sampo; Kline, Keith L.; ...

    2017-06-27

    In order to understand the climate effects of a bioenergy system, a comparison between the bioenergy system and a reference system is required. The reference system describes the situation that occurs in the absence of the bioenergy system with respect to the use of land, energy, and materials. The importance of reference systems is discussed in the literature but guidance on choosing suitable reference systems for assessing climate effects of bioenergy is limited. The reference system should align with the purpose of the study. Transparency of reference system assumptions is essential for proper interpretation of bioenergy assessments. This paper presentsmore » guidance for selecting suitable reference systems. Particular attention is given to choosing the land reference. If the goal is to study the climate effects of bioenergy as a part of total anthropogenic activity the reference system should illustrate what is expected in the absence of human activities. In such a case the suitable land reference is natural regeneration, and energy or material reference systems are not relevant. If the goal is to assess the effect of a change in bioenergy use, the reference system should incorporate human activities. In this case suitable reference systems describe the most likely alternative uses of the land, energy and materials in the absence of the change in bioenergy use. The definition of the reference system is furthermore subject to the temporal scope of the study. In practice, selecting and characterizing reference systems will involve various choices and uncertainties which should be considered carefully. As a result, it can be instructive to consider how alternative reference systems influence the results and conclusions drawn from bioenergy assessments.« less

  1. Development of NIST standard reference material 2373: Genomic DNA standards for HER2 measurements.

    PubMed

    He, Hua-Jun; Almeida, Jamie L; Lund, Steve P; Steffen, Carolyn R; Choquette, Steve; Cole, Kenneth D

    2016-06-01

    NIST standard reference material (SRM) 2373 was developed to improve the measurements of the HER2 gene amplification in DNA samples. SRM 2373 consists of genomic DNA extracted from five breast cancer cell lines with different amounts of amplification of the HER2 gene. The five components are derived from the human cell lines SK-BR-3, MDA-MB-231, MDA-MB-361, MDA-MB-453, and BT-474. The certified values are the ratios of the HER2 gene copy numbers to the copy numbers of selected reference genes DCK, EIF5B, RPS27A, and PMM1. The ratios were measured using quantitative polymerase chain reaction and digital PCR, methods that gave similar ratios. The five components of SRM 2373 have certified HER2 amplification ratios that range from 1.3 to 17.7. The stability and homogeneity of the reference materials were shown by repeated measurements over a period of several years. SRM 2373 is a well characterized genomic DNA reference material that can be used to improve the confidence of the measurements of HER2 gene copy number.

  2. A new isotopic reference material for stable hydrogen and oxygen isotope-ratio measurements of water—USGS50 Lake Kyoga Water

    USGS Publications Warehouse

    Coplen, Tyler B.; Wassenaar, Leonard I; Mukwaya, Christine; Qi, Haiping; Lorenz, Jennifer M.

    2015-01-01

    This isotopic reference material, designated as USGS50, is intended as one of two reference waters for daily normalization of stable hydrogen and oxygen isotopic analysis of water with an isotope-ratio mass spectrometer or a laser absorption spectrometer, of use especially for isotope-hydrology laboratories analyzing freshwater samples from equatorial and tropical regions.

  3. Antarctic ice-core water (USGS49) – A new isotopic reference material for δ2H and δ18O measurements of water

    USGS Publications Warehouse

    Lorenz, Jennifer M.; Qi, Haiping; Coplen, Tyler B.

    2017-01-01

    As a result of the scarcity of isotopic reference waters for daily use, a new secondary isotopic reference material for international distribution has been prepared from ice-core water from the Amundsen–Scott South Pole Station. This isotopic reference material, designated as USGS49, was filtered, homogenised, loaded into glass ampoules, sealed with a torch, autoclaved to eliminate biological activity and measured by dual-inlet isotope-ratio mass spectrometry. The δ2H and δ18O values of USGS49 are −394.7 ± 0.4 and −50.55 ± 0.04 mUr (where mUr = 0.001 = ‰), respectively, relative to VSMOW, on scales normalised such that the δ2H and δ18O values of SLAP reference water are, respectively, −428 and −55.5 mUr. Each uncertainty is an estimated expanded uncertainty (U = 2uc) about the reference value that provides an interval that has about a 95% probability of encompassing the true value. This isotopic reference material is intended as one of two isotopic reference waters for daily normalisation of stable hydrogen and oxygen isotopic analysis of water with an isotope-ratio mass spectrometer or a laser absorption spectrometer. It is available by the case of 144 glass ampoules or as a set of sixteen glass ampoules containing 5 ml of water in each ampoule.

  4. The Kjeldahl method as a primary reference procedure for total protein in certified reference materials used in clinical chemistry. I. A review of Kjeldahl methods adopted by laboratory medicine.

    PubMed

    Chromý, Vratislav; Vinklárková, Bára; Šprongl, Luděk; Bittová, Miroslava

    2015-01-01

    We found previously that albumin-calibrated total protein in certified reference materials causes unacceptable positive bias in analysis of human sera. The simplest way to cure this defect is the use of human-based serum/plasma standards calibrated by the Kjeldahl method. Such standards, commutative with serum samples, will compensate for bias caused by lipids and bilirubin in most human sera. To find a suitable primary reference procedure for total protein in reference materials, we reviewed Kjeldahl methods adopted by laboratory medicine. We found two methods recommended for total protein in human samples: an indirect analysis based on total Kjeldahl nitrogen corrected for its nonprotein nitrogen and a direct analysis made on isolated protein precipitates. The methods found will be assessed in a subsequent article.

  5. [Preparation and certification of mussel reference material for organochlorine pesticides and polychlorinated biphenyls using isotope dilution-high resolution mass spectrometry].

    PubMed

    Lu, Xianbo; Chen, Jiping; Wang, Shuqiu; Zou, Lili; Tian, Yuzeng; Ni, Yuwen; Su, Fan

    2012-09-01

    A method for the preparation and certification of the reference material of organochlorine pesticides (OCPs) and polychlorinated biphenyls (PCBs) in mussel tissue is described. The mussel tissue from Dalian Bay was frozen-dried, comminuted, sieved, homogenized, packaged, and sterilized by 60Co radiation sterilization in turn. The certified values for 18 OCPs and 16 PCBs were determined by high resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS) using isotope dilution and internal standard quantitation techniques. The certified values were validated and given based on seven accredited laboratories, and these values are traceable to the SI (international system of units) through gravimetrically prepared standards of established purity and measurement intercomparisons. The certified values of PCBs and OCPs in mussel span 4 orders of magnitude with a relative uncertainty of about 10%. This material is a natural biological material with confirmed good homogeneity and stability, and it was approved as the grade "primary reference material" (GBW10069) in June 2012 in China. This reference material provided necessary quality control products for our country to implement the Stockholm Treaty on the monitoring of persistent organic pollutants (POPs). The material is intended to be used for the method validation and quality control in the determination of OCPs and PCBs in biota samples.

  6. Comprehensive inter-laboratory calibration of reference materials for δ18O versus VSMOW using various on-line high-temperature conversion techniques

    USGS Publications Warehouse

    Brand, Willi A.; Coplen, Tyler B.; Aerts-Bijma, Anita T.; Bohlke, John Karl; Gehre, Matthias; Geilmann, Heike; Groning, Manfred; Jansen, Henk G.; Meijer, Harro A. J.; Mroczkowski, Stanley J.; Qi, Haiping; Soergel, Karin; Stuart-Williams, Hilary; Weise, Stephan M.; Werner, Roland A.

    2009-01-01

    Internationally distributed organic and inorganic oxygen isotopic reference materials have been calibrated by six laboratories carrying out more than 5300 measurements using a variety of high-temperature conversion techniques (HTC) in an evaluation sponsored by the International Union of Pure and Applied Chemistry (IUPAC). To aid in the calibration of these reference materials, which span more than 125‰, an artificially enriched reference water (δ18O of +78.91‰) and two barium sulfates (one depleted and one enriched in 18O) were prepared and calibrated relative to VSMOW2 and SLAP reference waters. These materials were used to calibrate the other isotopic reference materials in this study, which yielded:Reference materialδ18O and estimated combined uncertainty IAEA-602 benzoic acid+71.28 ± 0.36‰USGS35 sodium nitrate+56.81 ± 0.31‰IAEA-NO-3 potassium nitrate+25.32 ± 0.29‰IAEA-601 benzoic acid+23.14 ± 0.19‰IAEA-SO-5 barium sulfate+12.13 ± 0.33‰NBS 127 barium sulfate+8.59 ± 0.26‰VSMOW2 water0‰IAEA-600 caffeine−3.48 ± 0.53‰IAEA-SO-6 barium sulfate−11.35 ± 0.31‰USGS34 potassium nitrate−27.78 ± 0.37‰SLAP water−55.5‰The seemingly large estimated combined uncertainties arise from differences in instrumentation and methodology and difficulty in accounting for all measurement bias. They are composed of the 3-fold standard errors directly calculated from the measurements and provision for systematic errors discussed in this paper. A primary conclusion of this study is that nitrate samples analyzed for δ18O should be analyzed with internationally distributed isotopic nitrates, and likewise for sulfates and organics. Authors reporting relative differences of oxygen-isotope ratios (δ18O) of nitrates, sulfates, or organic material should explicitly state in their reports the δ18O values of two or more internationally distributed nitrates (USGS34, IAEA-NO-3, and USGS35), sulfates (IAEA-SO-5, IAEA-SO-6, and NBS 127), or organic material (IAEA-601 benzoic acid, IAEA-602 benzoic acid, and IAEA-600 caffeine), as appropriate to the material being analyzed, had these reference materials been analyzed with unknowns. This procedure ensures that readers will be able to normalize the δ18O values at a later time should it become necessary.The high-temperature reduction technique for analyzing δ18O and δ2H is not as widely applicable as the well-established combustion technique for carbon and nitrogen stable isotope determination. To obtain the most reliable stable isotope data, materials should be treated in an identical fashion; within the same sequence of analyses, samples should be compared with working reference materials that are as similar in nature and in isotopic composition as feasible.

  7. 9 CFR 77.1 - Material incorporated by reference.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... AGRICULTURE INTERSTATE TRANSPORTATION OF ANIMALS (INCLUDING POULTRY) AND ANIMAL PRODUCTS TUBERCULOSIS General Provisions § 77.1 Material incorporated by reference. Uniform Methods and Rules—Bovine Tuberculosis Eradication. The Uniform Methods and Rules—Bovine Tuberculosis Eradication (January 22, 1999, edition) has...

  8. 9 CFR 77.1 - Material incorporated by reference.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... AGRICULTURE INTERSTATE TRANSPORTATION OF ANIMALS (INCLUDING POULTRY) AND ANIMAL PRODUCTS TUBERCULOSIS General Provisions § 77.1 Material incorporated by reference. Uniform Methods and Rules—Bovine Tuberculosis Eradication. The Uniform Methods and Rules—Bovine Tuberculosis Eradication (January 22, 1999, edition) has...

  9. 9 CFR 77.1 - Material incorporated by reference.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... AGRICULTURE INTERSTATE TRANSPORTATION OF ANIMALS (INCLUDING POULTRY) AND ANIMAL PRODUCTS TUBERCULOSIS General Provisions § 77.1 Material incorporated by reference. Uniform Methods and Rules—Bovine Tuberculosis Eradication. The Uniform Methods and Rules—Bovine Tuberculosis Eradication (January 22, 1999, edition) has...

  10. 9 CFR 77.1 - Material incorporated by reference.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... AGRICULTURE INTERSTATE TRANSPORTATION OF ANIMALS (INCLUDING POULTRY) AND ANIMAL PRODUCTS TUBERCULOSIS General Provisions § 77.1 Material incorporated by reference. Uniform Methods and Rules—Bovine Tuberculosis Eradication. The Uniform Methods and Rules—Bovine Tuberculosis Eradication (January 22, 1999, edition) has...

  11. 9 CFR 77.1 - Material incorporated by reference.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... AGRICULTURE INTERSTATE TRANSPORTATION OF ANIMALS (INCLUDING POULTRY) AND ANIMAL PRODUCTS TUBERCULOSIS General Provisions § 77.1 Material incorporated by reference. Uniform Methods and Rules—Bovine Tuberculosis Eradication. The Uniform Methods and Rules—Bovine Tuberculosis Eradication (January 22, 1999, edition) has...

  12. Development and Characterization of Reference Materials for Genetic Testing: Focus on Public Partnerships.

    PubMed

    Kalman, Lisa V; Datta, Vivekananda; Williams, Mickey; Zook, Justin M; Salit, Marc L; Han, Jin Yeong

    2016-11-01

    Characterized reference materials (RMs) are needed for clinical laboratory test development and validation, quality control procedures, and proficiency testing to assure their quality. In this article, we review the development and characterization of RMs for clinical molecular genetic tests. We describe various types of RMs and how to access and utilize them, especially focusing on the Genetic Testing Reference Materials Coordination Program (Get-RM) and the Genome in a Bottle (GIAB) Consortium. This review also reinforces the need for collaborative efforts in the clinical genetic testing community to develop additional RMs.

  13. Preparation of reference material for UGT1A1 (TA)n polymorphism genotyping.

    PubMed

    Mlakar, Vid; Mlakar, Simona Jurković; Marc, Janja; Ostanek, Barbara

    2014-08-05

    Gilbert's syndrome is one of the most common metabolic syndromes in the human population characterised by mild unconjugated hyperbilirubinemia resulting from reduced activity of the bilirubin conjugating enzyme UDP-glucuronosyltransferase (UGT1A1). Although Gilbert's syndrome is usually quite benign UGT1A1(TA)n genotyping is important in exclusion of more serious causes of hyperbilirubinemia and since it has significant implications for personalised medicine. The aim of our study was to develop plasmid based reference materials which could be used for UGT1A1(TA)n genotyping. Plasmids were generated using recombinant DNA technology and their number of repeats as well as the entire sequence verified by Sanger sequencing. Their suitability as reference materials was tested using sizing by capillary electrophoresis and denaturing high performance liquid chromatography. Plasmids containing all four different alleles (TA)5, (TA)6, (TA)7 and (TA)8 that are present in the human population as well as a plasmid with (TA)4 repeats were successfully generated. Prepared plasmid reference materials allow the creation of all possible UGT1A1(TA)n polymorphism genotypes and can serve as an efficient substitute for the human genomic DNA reference material in routine genotyping and in the development of new genotyping tests. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Apparatus configured for identification of a material and method of identifying a material

    DOEpatents

    Slater, John M.; Crawford, Thomas M.; Frickey, Dean A.

    2001-01-01

    The present invention relates to an apparatus configured for identification of a material and method of identifying a material. One embodiment of the present invention provides an apparatus configured for identification of a material including a first region configured to receive a first sample and output a first spectrum responsive to exposure of the first sample to radiation; a signal generator configured to provide a reference signal having a reference frequency and a modulation signal having a modulation frequency; a modulator configured to selectively modulate the first spectrum using the modulation signal according to the reference frequency; a second region configured to receive a second sample and output a second spectrum responsive to exposure of the second sample to the first spectrum; and a detector configured to detect the second spectrum.

  15. New reference materials for nitrogen-isotope-ratio measurements

    USGS Publications Warehouse

    Böhlke, John Karl; Gwinn, C. J.; Coplen, T. B.

    1993-01-01

    Three new reference materials were manufactured for calibration of relative stable nitrogen-isotope-ratio measurements: USGS25 (ammonium sulfate) d15N' = -30 per mil; USGS26 (ammonium sulfate) d15N' = +54 per mil; USGS32 (potassium nitrate) d15N' = +180 per mil, where d15N', relative to atmospheric nitrogen, is an approximate value subject to change following interlaboratory comparisons. These materials are isotopically homogeneous in aliquots at least as small as 10 µmol N2 (or about 1-2 mg of salt). The new reference materials greatly extend the range of d15N values of internationally distributed standards, and they allow normalization of d15N measurements over almost the full range of known natural isotope variation on Earth. The methods used to produce these materials may be adapted to produce homogeneous local laboratory standards for routine use.

  16. Advertising content in physical activity print materials.

    PubMed

    Cardinal, Bradley J

    2002-01-01

    Copies of 80 sets of print materials available free of charge to the general public were analyzed to determine the relationship between the developer and advertising-related material. Almost all of the materials had some form of advertising content. Materials from commercial product vendors were most likely to have product logos, references to specific brands, and had the greatest number of logos, and the greatest number of references to specific brands. They were the second most likely to have advertising slogans, and had the second greatest number of advertising slogans.

  17. High rate, long cycle life battery electrode materials with an open framework structure

    DOEpatents

    Wessells, Colin; Huggins, Robert; Cui, Yi; Pasta, Mauro

    2015-02-10

    A battery includes a cathode, an anode, and an aqueous electrolyte disposed between the cathode and the anode and including a cation A. At least one of the cathode and the anode includes an electrode material having an open framework crystal structure into which the cation A is reversibly inserted during operation of the battery. The battery has a reference specific capacity when cycled at a reference rate, and at least 75% of the reference specific capacity is retained when the battery is cycled at 10 times the reference rate.

  18. The role of ion mobility spectrometry-mass spectrometry in the analysis of protein reference standards.

    PubMed

    Pritchard, Caroline; O'Connor, Gavin; Ashcroft, Alison E

    2013-08-06

    To achieve comparability of measurement results of protein amount of substance content between clinical laboratories, suitable reference materials are required. The impact on measurement comparability of potential differences in the tertiary and quaternary structure of protein reference standards is as yet not well understood. With the use of human growth hormone as a model protein, the potential of ion mobility spectrometry-mass spectrometry as a tool to assess differences in the structure of protein reference materials and their interactions with antibodies has been investigated here.

  19. Investigation of preparation techniques for δ2H analysis of keratin materials and a proposed analytical protocol

    USGS Publications Warehouse

    Qi, H.; Coplen, T.B.

    2011-01-01

    Accurate hydrogen isotopic measurements of keratin materials have been a challenge due to exchangeable hydrogen in the sample matrix and the paucity of appropriate isotopic reference materials for calibration. We found that the most reproducible δ2HVSMOW-SLAP and mole fraction of exchangeable hydrogen, x(H)ex, of keratin materials were measured with equilibration at ambient temperature using two desiccators and two different equilibration waters with two sets of the keratin materials for 6 days. Following equilibration, drying the keratin materials in a vacuum oven for 4 days at 60 °C was most critical. The δ2H analysis protocol also includes interspersing isotopic reference waters in silver tubes among samples in the carousel of a thermal conversion elemental analyzer (TC/EA) reduction unit. Using this analytical protocol, δ2HVSMOW-SLAP values of the non-exchangeable fractions of USGS42 and USGS43 human-hair isotopic reference materials were determined to be –78.5 ± 2.3 ‰ and –50.3 ± 2.8 ‰, respectively. The measured x(H)ex values of keratin materials analyzed with steam equilibration and N2 drying were substantially higher than those previously published, and dry N2 purging was unable to remove absorbed moisture completely, even with overnight purging. The δ2H values of keratin materials measured with steam equilibration were about 10 ‰ lower than values determined with equilibration in desiccators at ambient temperatures when on-line evacuation was used to dry samples. With steam equilibrations the x(H)ex of commercial keratin powder was as high as 28 %. Using human-hair isotopic reference materials to calibrate other keratin materials, such as hoof or horn, can introduce bias in δ2H measurements because the amount of absorbed water and the x(H)ex values may differ from those of unknown samples. Correct δ2HVSMOW-SLAP values of the non-exchangeable fractions of unknown human-hair samples can be determined with atmospheric moisture equilibration by normalizing with USGS42 and USGS43 human-hair reference materials when all materials have the same powder size.

  20. Spatial analysis of charcoal kiln remains in the former royal forest district Tauer (Lower Lusatia, North German Lowlands)

    NASA Astrophysics Data System (ADS)

    Raab, Alexandra; Schneider, Anna; Bonhage, Alexander; Takla, Melanie; Hirsch, Florian; Müller, Frank; Rösler, Horst; Heußner, Karl-Uwe

    2016-04-01

    Archaeological excavations have revealed more than thousand charcoal kiln remains (CKRs) in the prefield of the active opencast lignite mine Jänschwalde, situated about 150 km SE of Berlin (SE Brandenburg, Germany). The charcoal was mainly produced for the ironwork Peitz nearby, which operated from the 16th to the mid-19th centuries. In a first approach, to estimate the dimension of the charcoal production, CKRs were mapped on shaded-relief maps (SRMs) derived from high-resolution LiDAR data (Raab et al. 2015). Subsequently, for a selected test area, identified CKRs on the SRMs were compared with archaeologically excavated CKRs in the field. This survey showed a considerably number of falsely detected sites. Therefore, the data was critically re-evaluated using additional relief visualisations. Further, we extended the CKR mapping to areas which are not archaeologically investigated. The study area, the former royal forest district Tauer, consists of two separate areas: the Tauersche Heide (c. 96 km2 area) N of Peitz and the area Jänschwalde (c. 32 km2 area) NE of Peitz. The study area is characterized by a flat topography. Different former and current anthropogenic uses (e.g., military training, solar power plant, forestry measures) have affected the study area, resulting in extensive disturbances of the terrain surface. The revised CKR abundance in the study area Jänschwalde was considerably smaller than the numbers produced by our first approach. Further, the CKR mapping revealed, that a total record of the CKRs is not possible for various reasons. Despite these limitations, a solid database can be provided for a much larger area than before. Basic statistic parameters of the CKR diameters and all comparative statistical tests were calculated using SPSS. To detect underlying spatial relationships in the CKR site distribution, we applied the Getis-Ord Gi* statistic, a method to test for local spatial autocorrelation between neighbouring sites. The test is available as part of the ArcGis 10.1 spatial statistics toolbox. The outcomes are discussed in consideration of our archaeological, archival and dendrochronological research results. Raab, A., Takla, M., Raab, T., Nicolay, A., Schneider, A., Rösler, H., et al. (2015). Pre-industrial charcoal production in Lower Lusatia (Brandenburg, Germany): Detection and evaluation of a large charcoal-burning field by combining archaeological studies, GIS-based analyses of shaded-relief maps and dendrochronological age determination. Quaternary International, doi:http://dx.doi.org/10.1016/j.quaint.2014.09.041.

  1. Energy Guide: A Directory of Information Resources.

    ERIC Educational Resources Information Center

    Bemis, Virginia; And Others

    This guide is a collection of various information sources pertaining to energy. The chapters separate references according to the type of material (instructional aids, texts, periodicals, reference materials), or the issuing organization (non-government organizations, government services, courses, programs, centers, and research projects). One…

  2. A Development Strategy for Creating a Suite of Reference Materials for the in-situ Microanalysis of Non-conventional Raw Materials

    NASA Astrophysics Data System (ADS)

    Renno, A. D.; Merchel, S.; Michalak, P. P.; Munnik, F.; Wiedenbeck, M.

    2010-12-01

    Recent economic trends regarding the supply of rare metals readily justify scientific research into non-conventional raw materials, where a particular need is a better understanding of the relationship between mineralogy, microstructure and the distribution of key metals within ore deposits (geometallurgy). Achieving these goals will require an extensive usage of in-situ microanalytical techniques capable of spatially resolving material heterogeneities which can be key for understanding better resource utilization. The availability of certified reference materials (CRMs) is an essential prerequisite for (1) validating new analytical methods, (2) demonstrating data quality to the contracting authorities, (3) supporting method development and instrument calibration, and (4) establishing traceability between new analytical approaches and existing data sets. This need has led to the granting of funding by the European Union and the German Free State of Saxony for a program to develop such reference materials . This effort will apply the following strategies during the selection of the phases: (1) will use exclusively synthetic minerals, thereby providing large volumes of homogeneous starting material. (2) will focus on matrices which are capable of incorporating many ‘important’ elements while avoid exotic compositions which would not be optimal matrix matches. (3) will emphasise those phases which remain stable during the various microanalytical procedure. This initiative will assess the homogeneity of the reference materials at sampling sizes ranging between 50 and 1 µm; it is also intended to document crystal structural homogeneity too, as this too may potentially impact specific analytical methods. As far as possible both definitive methods as well as methods involving matrix corrections will be used for determining the compositions of the of the individual materials. A critical challenge will be the validation of the determination of analytes concentrations as sub-µg sampling masses. It is planned to cooperate with those who are interested in the development of such reference materials and we invite them to take part in round-robin exercises.

  3. CRISPR/Cas9 Technology-Based Xenograft Tumors as Candidate Reference Materials for Multiple EML4-ALK Rearrangements Testing.

    PubMed

    Peng, Rongxue; Zhang, Rui; Lin, Guigao; Yang, Xin; Li, Ziyang; Zhang, Kuo; Zhang, Jiawei; Li, Jinming

    2017-09-01

    The echinoderm microtubule-associated protein-like 4 and anaplastic lymphoma kinase (ALK) receptor tyrosine kinase (EML4-ALK) rearrangement is an important biomarker that plays a pivotal role in therapeutic decision making for non-small-cell lung cancer (NSCLC) patients. Ensuring accuracy and reproducibility of EML4-ALK testing by fluorescence in situ hybridization, immunohistochemistry, RT-PCR, and next-generation sequencing requires reliable reference materials for monitoring assay sensitivity and specificity. Herein, we developed novel reference materials for various kinds of EML4-ALK testing. CRISPR/Cas9 was used to edit various NSCLC cell lines containing EML4-ALK rearrangement variants 1, 2, and 3a/b. After s.c. inoculation, the formalin-fixed, paraffin-embedded (FFPE) samples from xenografts were prepared and tested for suitability as candidate reference materials by fluorescence in situ hybridization, immunohistochemistry, RT-PCR, and next-generation sequencing. Sample validation and commutability assessments showed that all types of FFPE samples derived from xenograft tumors have typical histological structures, and EML4-ALK testing results were similar to the clinical ALK-positive NSCLC specimens. Among the four methods for EML4-ALK detection, the validation test showed 100% concordance. Furthermore, these novel FFPE reference materials showed good stability and homogeneity. Without limitations on variant types and production, our novel FFPE samples based on CRISPR/Cas9 editing and xenografts are suitable as candidate reference materials for the validation, verification, internal quality control, and proficiency testing of EML4-ALK detection. Copyright © 2017 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  4. Two new organic reference materials for δ13C and δ15N measurements and a new value for the δ13C of NBS 22 oil

    USGS Publications Warehouse

    Qi, Haiping; Coplen, Tyler B.; Geilmann, Heike; Brand, Willi A.; Böhlke, J.K.

    2003-01-01

    Analytical grade L-glutamic acid is chemically stable and has a C/N mole ratio of 5, which is close to that of many of natural biological materials, such as blood and animal tissue. Two L-glutamic acid reference materials with substantially different 13C and 15N abundances have been prepared for use as organic reference materials for C and N isotopic measurements. USGS40 is analytical grade L-glutamic acid and has a δ13C value of −26.24‰ relative to VPDB and a δ15N value of −4.52‰ relative to N2 in air. USGS41 was prepared by dissolving analytical grade L-glutamic acid with L-glutamic acid enriched in 13C and 15N. USGS41 has a δ13C value of +37.76‰ and a δ15N value of +47.57‰. The δ13C and δ15N values of both materials were measured against the international reference materials NBS 19 calcium carbonate (δ13C = +1.95‰), L-SVEC lithium carbonate (δ13C = −46.48‰), IAEA-N-1 ammonium sulfate (δ15N = 0.43‰), and USGS32 potassium nitrate (δ15N = 180‰) by on-line combustion continuous-flow and off-line dual-inlet isotope-ratio mass spectrometry. Both USGS40 and USGS41 are isotopically homogeneous; reproducibility of δ13C is better than 0.13‰, and that of δ15N is better than 0.13‰ in 100-μg amounts. These two isotopic reference materials can be used for (i) calibrating local laboratory reference materials, and (ii) quantifying drift with time, mass-dependent fractionations, and isotope-ratio-scale contraction in the isotopic analysis of various biological materials. Isotopic results presented in this paper yield a δ13C value for NBS 22 oil of −29.91‰, in contrast to the commonly accepted value of −29.78‰ for which off-line blank corrections probably have not been quantified satisfactorily.

  5. In vitro testing of Nd:YAG laser processed calcium phosphate coatings.

    PubMed

    De Carlos, A; Lusquiños, F; Pou, J; León, B; Pérez-Amor, M; Driessens, F C M; Hing, K; Best, S; Bonfield, W

    2006-11-01

    Nd:YAG laser cladding is a new method for deposition of a calcium phosphate onto metallic surfaces of interest in implantology. The aim of this study was to compare the biologic response of MG-63 human osteoblast-like cells grown on Ti-6Al-4V substrates coated with a calcium phosphate layer applied using different methods: plasma spraying as reference material and Nd:YAG laser cladding as test material. Tissue culture polystyrene was used as negative control. The Nd:YAG laser clad material showed a behaviour similar to the reference material, plasma spray, respective to cell morphology (SEM observations), cell proliferation (AlamarBlue assay) and cytotoxicity of extracts (MTT assay). Proliferation, as measured by the AlamarBlue assay, showed little difference in the metabolic activity of the cells on the materials over an 18 day culture period. There were no significant differences in the cellular growth response on the test material when compared to the ones exhibited by the reference material. In the solvent extraction test all the extracts had some detrimental effect on cellular activity at 100% concentration, although cells incubated in the test material extract showed a proliferation rate similar to that of the reference material. To better understand the scope of these results it should be taken into account that the Nd:YAG clad coating has recently been developed. The fact that its in vitro performance is comparable to that produced by plasma spray, a material commercially available for more than ten years, indicates that this new laser based method could be of commercial interest in the near future.

  6. Committee on Diabetes Mellitus Indices of the Japan Society of Clinical Chemistry-recommended reference measurement procedure and reference materials for glycated albumin determination.

    PubMed

    Takei, Izumi; Hoshino, Tadao; Tominaga, Makoto; Ishibashi, Midori; Kuwa, Katsuhiko; Umemoto, Masao; Tani, Wataru; Okahashi, Mikiko; Yasukawa, Keiko; Kohzuma, Takuji; Sato, Asako

    2016-01-01

    Glycated albumin is an intermediate glycaemic control marker for which there are several measurement procedures with entirely different reference intervals. We have developed a reference measurement procedure for the purpose of standardizing glycated albumin measurements. The isotope dilution liquid chromatography/tandem mass spectrometry method was developed as a reference measurement procedure for glycated albumin. The stable isotopes of lysine and fructosyl-lysine, which serve as an internal standard, were added to albumin isolated from serum, followed by hydrogenation. After hydrolysis of albumin with hot hydrochloric acid, the liberated lysine and fructosyl-lysine were measured by liquid chromatography/tandem mass spectrometry, and their concentrations were determined from each isotope ratio. The reference materials (JCCRM611) for determining of glycated albumin were prepared from pooled patient blood samples. The isotope dilution-tandem mass spectrometry calibration curve of fructosyl-lysine and lysine showed good linearity (r = 0.999). The inter-assay and intra-assay coefficient of variation values of glycated albumin measurement were 1.2 and 1.4%, respectively. The glycated albumin values of serum in patients with diabetes assessed through the use of this method showed a good relationship with routine measurement procedures (r = 0.997). The relationship of glycated albumin values of the reference material (JCCRM611) between these two methods was the same as the relationship with the patient serum samples. The Committee on Diabetes Mellitus Indices of the Japan Society of Clinical Chemistry recommends the isotope dilution liquid chromatography/tandem mass spectrometry method as a reference measurement procedure, and JCCRM611 as a certified reference material for glycated albumin measurement. In addition, we recommend the traceability system for glycated albumin measurement. © The Author(s) 2015.

  7. Isotope reference materials

    USGS Publications Warehouse

    Coplen, Tyler B.

    2010-01-01

    Measurement of the same isotopically homogeneous sample by any laboratory worldwide should yield the same isotopic composition within analytical uncertainty. International distribution of light element isotopic reference materials by the International Atomic Energy Agency and the U.S. National Institute of Standards and Technology enable laboratories to achieve this goal.

  8. 46 CFR 164.013-2 - Incorporation by reference.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 6 2011-10-01 2011-10-01 false Incorporation by reference. 164.013-2 Section 164.013-2 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL MATERIALS Foam, Unicellular Polyethylene (Buoyant, Slab, Slitted Trigonal Pattern...

  9. 46 CFR 164.013-2 - Incorporation by reference.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Incorporation by reference. 164.013-2 Section 164.013-2 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL MATERIALS Foam, Unicellular Polyethylene (Buoyant, Slab, Slitted Trigonal Pattern...

  10. 40 CFR 1042.910 - Reference materials.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... incorporated by reference into this part. The Director of the Federal Register approved the incorporation by... and Radiation Docket and Information Center, 1301 Constitution Ave., NW., Room B102, EPA West Building.../federal_register/code_of_federal_regulations/ibr_locations.html. (a) IMO material. This paragraph (a...

  11. 40 CFR 1043.100 - Reference materials.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... this part. The Director of the Federal Register approved the incorporation by reference as prescribed... Docket and Information Center, 1301 Constitution Ave., NW., Room B102, EPA West Building, Washington, DC.../federal_register/code_of_federal_regulations/ibr_locations.html. (a) IMO material. This paragraph (a...

  12. 40 CFR 1043.100 - Reference materials.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... this part. The Director of the Federal Register approved the incorporation by reference as prescribed... Docket and Information Center, 1301 Constitution Ave., NW., Room B102, EPA West Building, Washington, DC.../federal_register/code_of_federal_regulations/ibr_locations.html. (a) IMO material. This paragraph (a...

  13. 40 CFR 1042.910 - Reference materials.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... incorporated by reference into this part. The Director of the Federal Register approved the incorporation by... and Radiation Docket and Information Center, 1301 Constitution Ave., NW., Room B102, EPA West Building.../federal_register/code_of_federal_regulations/ibr_locations.html. (a) IMO material. This paragraph (a...

  14. 40 CFR 1065.1010 - Reference materials.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... § 1065.1010—Institute of Petroleum Materials Document No. and name Part 1065 reference IP-470... atomic absorption spectrometry 1065.705 IP-500, Determination of the phosphorus content of residual fuels by ultra-violet spectrometry 1065.705 IP-501, Determination of aluminum, silicon, vanadium, nickel...

  15. Development of a candidate reference measurement procedure for the analysis of cortisol in human serum samples by isotope dilution-gas chromatography-mass spectrometry.

    PubMed

    Kawaguchi, Migaku; Takatsu, Akiko

    2009-08-01

    A candidate reference measurement procedure involving isotope dilution coupled with gas chromatography-mass spectrometry (GC-MS) has been developed and critically evaluated. An isotopically labeled internal standard, cortisol-d(2), was added to a serum sample. After equilibration, solid-phase extractions (SPE) for sample preparation and derivatization with heptafluorobutyric anhydride (HFBA) were performed for GC-MS analysis. The limit of detection (LOD) and the limit of quantification (LOQ) were 5 and 20 ng g(-1), respectively. The recovery of the added cortisol ranged from 99.8 to 101.0%. Excellent precision was obtained with a within-day variation (RSD) of 0.7% for GC-MS analysis. The accuracy of the measurement was evaluated by comparing of results of this reference measurement procedure on lyophilized human serum reference materials for cortisol (European Reference Materials (ERM)-DA 192) as Certified Reference Materials (CRMs). The results of this method for total cortisol agreed with the certified values within some uncertainty. This method, which demonstrates simply, easy, good accuracy, high precision, and is free from interferences from structural analogues, qualifies as a reference measurement procedure.

  16. USGS48 Puerto Rico precipitation - A new isotopic reference material for δ2H and δ18O measurements of water

    USGS Publications Warehouse

    Qi, Haiping; Coplen, Tyler B.; Tarbox, Lauren V.; Lorenz, Jennifer M.; Scholl, Martha A.

    2014-01-01

    A new secondary isotopic reference material has been prepared from Puerto Rico precipitation, which was filtered, homogenised, loaded into glass ampoules, sealed with a torch, autoclaved to eliminate biological activity, and calibrated by dual-inlet isotope-ratio mass spectrometry. This isotopic reference material, designated as USGS48, is intended to be one of two isotopic reference waters for daily normalisation of stable hydrogen (δ2H) and stable oxygen (δ18O) isotopic analysis of water with a mass spectrometer or a laser absorption spectrometer. The δ2H and δ18O values of this reference water are−2.0±0.4 and−2.224±0.012 ‰, respectively, relative to Vienna Standard Mean Ocean Water on scales normalised such that the δ2H and δ18O values of Standard Light Antarctic Precipitation reference water are−428 and−55.5 ‰, respectively. Each uncertainty is an estimated expanded uncertainty (U=2uc) about the reference value that provides an interval that has about a 95 % probability of encompassing the true value. This isotopic reference water is available by the case of 144 glass ampoules containing 5 mL of water in each ampoule.

  17. Alternative mass reference standards for direct analysis in real time mass spectrometry.

    PubMed

    Cody, Robert B; Dane, A John

    2016-05-30

    Mass spectra were acquired with the Direct Analysis in Real Time (DART®) ion source for an amine-terminated polyether used as positive-ion mass reference standards and for several fluorinated materials commonly used as negative-ion reference standards for mass spectrometry. A commercial time-of-flight mass spectrometer equipped with a DART ion source was used for all measurements. Mass reference standards deposited onto the sealed end of a glass melting point tube were suspended in the DART gas stream for analysis. A polyetheramine (Jeffamine® M-600) produced intense peaks corresponding to protonated molecules. Perfluorotributylamine (PFTBA), and perfluorotripentylamine, gave useful reference spectra for different m/z ranges. DART mass spectra of Ultramark 1621® resembled those previously reported for Fast Atom Bombardment (FAB) and Electrospray Ionization (ESI). Fomblin®Y, a fluorinated ether, was the most useful negative-ion reference standard of the materials tested. The material is commercially available, inexpensive, and provides reference peaks covering the m/z range 85 to >3000. Jeffamine-M600 was found to be a convenient alternative to polyethers such as polyethylene glycol (PEG) for DART positive-ion mass calibration. Fomblin Y was suitable for use as a negative-ion reference standard. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  18. Eddy-Current Reference Standard

    NASA Technical Reports Server (NTRS)

    Ambrose, H. H., Jr.

    1985-01-01

    Magnetic properties of metallic reference standards duplicated and stabilized for eddy-current coil measurements over long times. Concept uses precisely machined notched samples of known annealed materials as reference standards.

  19. Types of architectural structures and the use of smart materials

    NASA Astrophysics Data System (ADS)

    Tavşan, Cengiz; Sipahi, Serkan

    2017-07-01

    The developments in technology following the industrial revolution had their share of impact on both construction techniques, and material technologies. The change in the materials used by the construction industry brought along numerous innovations, which, in turn, took on an autonomous trend of development given the rise of nano-tech materials. Today, nano-tech materials are used extensively in numerous construction categories. Nano-tech materials, in general, are characterized by their reactionary nature, with the intent of repeating the reactions again and again under certain conditions. That is why nano-tech materials are often called smart materials. In construction industry, smart materials are categorized under 4 major perspectives: Shape-shifting smart materials, power generating smart materials, self-maintenance smart materials, and smart materials providing a high level of insulation. In architecture, various categories of construction often tend to exhibit their own approaches to design, materials, and construction techniques. This is a direct consequence of the need for different solutions for different functions. In this context, the use of technological materials should lead to the use of a set of smart materials for a given category of structures, while another category utilizes yet another set. In the present study, the smart materials used in specific categories of structures were reviewed with reference to nano-tech practices implemented in Europe, with a view to try and reveal the changes in the use of smart materials with reference to categories of structures. The study entails a discussion to test the hypothesis that nano-tech materials vary with reference to structure categories, on the basis of 18 examples from various structure categories, built by the construction firms with the highest level of potential in terms of doing business in Europe. The study comprises 3 major sections: The first section reiterates what the literature has to say about smart materials; the second discusses the types and characteristics of smart materials over the tables detailing their utilization and functions in the structures included in the set of examples. The final section of the study, on the other hand, elaborates on the findings, discussing them with reference to the types of structures.

  20. 10 CFR 435.3 - Material incorporated by reference.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 3 2011-01-01 2011-01-01 false Material incorporated by reference. 435.3 Section 435.3 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL LOW-RISE RESIDENTIAL BUILDINGS Mandatory Energy Efficiency Standards for Federal Low-Rise Residential Buildings. § 435...

  1. Historical considerations in evaluating timber structures

    Treesearch

    R. L. Tuomi; R. C. Moody

    1979-01-01

    Evaluation, maintenance, and upgrading of timber structures is an area where little printed reference material exists. This paper covers the state-of-the-art on design, material properties, and construction procedures on older buildings. Some guidelines are presented on rehabilitating and upgrading timber structures, along with significant references.

  2. 10 CFR 431.293 - Materials incorporated by reference.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    .... Department of Energy, Office of Energy Efficiency and Renewable Energy, Building Technologies Program, 6th... 10 Energy 3 2010-01-01 2010-01-01 false Materials incorporated by reference. 431.293 Section 431.293 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL...

  3. 10 CFR 433.3 - Materials incorporated by reference.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 3 2012-01-01 2012-01-01 false Materials incorporated by reference. 433.3 Section 433.3 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL COMMERCIAL.... Department of Energy, Office of Energy Efficiency and Renewable Energy, Building Technologies Program, Sixth...

  4. 10 CFR 431.293 - Materials incorporated by reference.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    .... Department of Energy, Office of Energy Efficiency and Renewable Energy, Building Technologies Program, 6th... 10 Energy 3 2011-01-01 2011-01-01 false Materials incorporated by reference. 431.293 Section 431.293 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL...

  5. 10 CFR 431.293 - Materials incorporated by reference.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    .... Department of Energy, Office of Energy Efficiency and Renewable Energy, Building Technologies Program, 6th... 10 Energy 3 2013-01-01 2013-01-01 false Materials incorporated by reference. 431.293 Section 431.293 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL...

  6. 10 CFR 431.63 - Materials incorporated by reference.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    .... Department of Energy, Office of Energy Efficiency and Renewable Energy, Building Technologies Program, 6th... 10 Energy 3 2011-01-01 2011-01-01 false Materials incorporated by reference. 431.63 Section 431.63 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND...

  7. 10 CFR 431.95 - Materials incorporated by reference.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Energy Efficiency and Renewable Energy, Hearings and Dockets, “Test Procedures and Efficiency Standards... 10 Energy 3 2012-01-01 2012-01-01 false Materials incorporated by reference. 431.95 Section 431.95 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND...

  8. 10 CFR 431.323 - Materials incorporated by reference.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... of Energy, Office of Energy Efficiency and Renewable Energy, Building Technologies Program, 6th Floor... 10 Energy 3 2012-01-01 2012-01-01 false Materials incorporated by reference. 431.323 Section 431.323 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL...

  9. 10 CFR 431.105 - Materials incorporated by reference.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ..., Office of Energy Efficiency and Renewable Energy, Building Technologies Program, 6th Floor, 950 L'Enfant... 10 Energy 3 2014-01-01 2014-01-01 false Materials incorporated by reference. 431.105 Section 431.105 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL...

  10. 10 CFR 431.63 - Materials incorporated by reference.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    .... Department of Energy, Office of Energy Efficiency and Renewable Energy, Building Technologies Program, 6th... 10 Energy 3 2014-01-01 2014-01-01 false Materials incorporated by reference. 431.63 Section 431.63 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND...

  11. 10 CFR 431.105 - Materials incorporated by reference.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ..., Office of Energy Efficiency and Renewable Energy, Building Technologies Program, 6th Floor, 950 L'Enfant... 10 Energy 3 2013-01-01 2013-01-01 false Materials incorporated by reference. 431.105 Section 431.105 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL...

  12. 10 CFR 433.3 - Materials incorporated by reference.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 3 2014-01-01 2014-01-01 false Materials incorporated by reference. 433.3 Section 433.3 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL COMMERCIAL.... Department of Energy, Office of Energy Efficiency and Renewable Energy, Building Technologies Program, Sixth...

  13. 10 CFR 431.63 - Materials incorporated by reference.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    .... Department of Energy, Office of Energy Efficiency and Renewable Energy, Building Technologies Program, 6th... 10 Energy 3 2012-01-01 2012-01-01 false Materials incorporated by reference. 431.63 Section 431.63 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND...

  14. 10 CFR 431.293 - Materials incorporated by reference.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    .... Department of Energy, Office of Energy Efficiency and Renewable Energy, Building Technologies Program, 6th... 10 Energy 3 2014-01-01 2014-01-01 false Materials incorporated by reference. 431.293 Section 431.293 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL...

  15. 10 CFR 431.293 - Materials incorporated by reference.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    .... Department of Energy, Office of Energy Efficiency and Renewable Energy, Building Technologies Program, 6th... 10 Energy 3 2012-01-01 2012-01-01 false Materials incorporated by reference. 431.293 Section 431.293 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL...

  16. 10 CFR 431.63 - Materials incorporated by reference.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    .... Department of Energy, Office of Energy Efficiency and Renewable Energy, Building Technologies Program, 6th... 10 Energy 3 2013-01-01 2013-01-01 false Materials incorporated by reference. 431.63 Section 431.63 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND...

  17. 10 CFR 433.3 - Materials incorporated by reference.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 3 2013-01-01 2013-01-01 false Materials incorporated by reference. 433.3 Section 433.3 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL COMMERCIAL.... Department of Energy, Office of Energy Efficiency and Renewable Energy, Building Technologies Program, Sixth...

  18. 10 CFR 431.323 - Materials incorporated by reference.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... of Energy, Office of Energy Efficiency and Renewable Energy, Building Technologies Program, 6th Floor... 10 Energy 3 2014-01-01 2014-01-01 false Materials incorporated by reference. 431.323 Section 431.323 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL...

  19. 40 CFR 432.5 - Incorporation by reference.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... AND STANDARDS MEAT AND POULTRY PRODUCTS POINT SOURCE CATEGORY § 432.5 Incorporation by reference. (a... Federal Register. The material is available for purchase at the address in paragraph (b) of this section..., Washington, DC. (b) The following material is available for purchase from the National Technical Information...

  20. 10 CFR 435.3 - Material incorporated by reference.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Material incorporated by reference. 435.3 Section 435.3 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL LOW-RISE RESIDENTIAL BUILDINGS Mandatory Energy Efficiency Standards for Federal Low-Rise Residential Buildings. § 435...

  1. External quality assurance programs as a tool for verifying standardization of measurement procedures: Pilot collaboration in Europe.

    PubMed

    Perich, C; Ricós, C; Alvarez, V; Biosca, C; Boned, B; Cava, F; Doménech, M V; Fernández-Calle, P; Fernández-Fernández, P; García-Lario, J V; Minchinela, J; Simón, M; Jansen, R

    2014-05-15

    Current external quality assurance schemes have been classified into six categories, according to their ability to verify the degree of standardization of the participating measurement procedures. SKML (Netherlands) is a Category 1 EQA scheme (commutable EQA materials with values assigned by reference methods), whereas SEQC (Spain) is a Category 5 scheme (replicate analyses of non-commutable materials with no values assigned by reference methods). The results obtained by a group of Spanish laboratories participating in a pilot study organized by SKML are examined, with the aim of pointing out the improvements over our current scheme that a Category 1 program could provide. Imprecision and bias are calculated for each analyte and laboratory, and compared with quality specifications derived from biological variation. Of the 26 analytes studied, 9 had results comparable with those from reference methods, and 10 analytes did not have comparable results. The remaining 7 analytes measured did not have available reference method values, and in these cases, comparison with the peer group showed comparable results. The reasons for disagreement in the second group can be summarized as: use of non-standard methods (IFCC without exogenous pyridoxal phosphate for AST and ALT, Jaffé kinetic at low-normal creatinine concentrations and with eGFR); non-commutability of the reference material used to assign values to the routine calibrator (calcium, magnesium and sodium); use of reference materials without established commutability instead of reference methods for AST and GGT, and lack of a systematic effort by manufacturers to harmonize results. Results obtained in this work demonstrate the important role of external quality assurance programs using commutable materials with values assigned by reference methods to correctly monitor the standardization of laboratory tests with consequent minimization of risk to patients. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Apparatus and method for identification and recognition of an item with ultrasonic patterns from item subsurface micro-features

    DOEpatents

    Perkins, Richard W.; Fuller, James L.; Doctor, Steven R.; Good, Morris S.; Heasler, Patrick G.; Skorpik, James R.; Hansen, Norman H.

    1995-01-01

    The present invention is a means and method for identification and recognition of an item by ultrasonic imaging of material microfeatures and/or macrofeatures within the bulk volume of a material. The invention is based upon ultrasonic interrogation and imaging of material microfeatures within the body of material by accepting only reflected ultrasonic energy from a preselected plane or volume within the material. An initial interrogation produces an identification reference. Subsequent new scans are statistically compared to the identification reference for making a match/non-match decision.

  3. Apparatus and method for identification and recognition of an item with ultrasonic patterns from item subsurface micro-features

    DOEpatents

    Perkins, R.W.; Fuller, J.L.; Doctor, S.R.; Good, M.S.; Heasler, P.G.; Skorpik, J.R.; Hansen, N.H.

    1995-09-26

    The present invention is a means and method for identification and recognition of an item by ultrasonic imaging of material microfeatures and/or macrofeatures within the bulk volume of a material. The invention is based upon ultrasonic interrogation and imaging of material microfeatures within the body of material by accepting only reflected ultrasonic energy from a preselected plane or volume within the material. An initial interrogation produces an identification reference. Subsequent new scans are statistically compared to the identification reference for making a match/non-match decision. 15 figs.

  4. Development of a Genomic DNA Reference Material Panel for Myotonic Dystrophy Type 1 (DM1) Genetic Testing

    PubMed Central

    Kalman, Lisa; Tarleton, Jack; Hitch, Monica; Hegde, Madhuri; Hjelm, Nick; Berry-Kravis, Elizabeth; Zhou, Lili; Hilbert, James E.; Luebbe, Elizabeth A.; Moxley, Richard T.; Toji, Lorraine

    2014-01-01

    Myotonic dystrophy type 1 (DM1) is caused by expansion of a CTG triplet repeat in the 3′ untranslated region of the DMPK gene that encodes a serine-threonine kinase. Patients with larger repeats tend to have a more severe phenotype. Clinical laboratories require reference and quality control materials for DM1 diagnostic and carrier genetic testing. Well-characterized reference materials are not available. To address this need, the Centers for Disease Control and Prevention-based Genetic Testing Reference Material Coordination Program, in collaboration with members of the genetic testing community, the National Registry of Myotonic Dystrophy and Facioscapulohumeral Muscular Dystrophy Patients and Family Members, and the Coriell Cell Repositories, has established and characterized cell lines from patients with DM1 to create a reference material panel. The CTG repeats in genomic DNA samples from 10 DM1 cell lines were characterized in three clinical genetic testing laboratories using PCR and Southern blot analysis. DMPK alleles in the samples cover four of five DM1 clinical categories: normal (5 to 34 repeats), mild (50 to 100 repeats), classical (101 to 1000 repeats), and congenital (>1000 repeats). We did not identify or establish Coriell cell lines in the premutation range (35 to 49 repeats). These samples are publicly available for quality control, proficiency testing, test development, and research and should help improve the accuracy of DM1 testing. PMID:23680132

  5. Quantification of the predominant monomeric catechins in baking chocolate standard reference material by LC/APCI-MS.

    PubMed

    Nelson, Bryant C; Sharpless, Katherine E

    2003-01-29

    Catechins are polyphenolic plant compounds (flavonoids) that may offer significant health benefits to humans. These benefits stem largely from their anticarcinogenic, antioxidant, and antimutagenic properties. Recent epidemiological studies suggest that the consumption of flavonoid-containing foods is associated with reduced risk of cardiovascular disease. Chocolate is a natural cocoa bean-based product that reportedly contains high levels of monomeric, oligomeric, and polymeric catechins. We have applied solid-liquid extraction and liquid chromatography coupled with atmospheric pressure chemical ionization-mass spectrometry to the identification and determination of the predominant monomeric catechins, (+)-catechin and (-)-epicatechin, in a baking chocolate Standard Reference Material (NIST Standard Reference Material 2384). (+)-Catechin and (-)-epicatechin are detected and quantified in chocolate extracts on the basis of selected-ion monitoring of their protonated [M + H](+) molecular ions. Tryptophan methyl ester is used as an internal standard. The developed method has the capacity to accurately quantify as little as 0.1 microg/mL (0.01 mg of catechin/g of chocolate) of either catechin in chocolate extracts, and the method has additionally been used to certify (+)-catechin and (-)-epicatechin levels in the baking chocolate Standard Reference Material. This is the first reported use of liquid chromatography/mass spectrometry for the quantitative determination of monomeric catechins in chocolate and the only report certifying monomeric catechin levels in a food-based Standard Reference Material.

  6. 40 CFR 63.1502 - Incorporation by reference.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Incorporation by reference. 63.1502... reference. (a) The following material is incorporated by reference in the corresponding sections noted. The incorporation by reference (IBR) of certain publications listed in the rule will be approved by the Director of...

  7. 49 CFR 384.107 - Matter incorporated by reference.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 5 2012-10-01 2012-10-01 false Matter incorporated by reference. 384.107 Section... COMPLIANCE WITH COMMERCIAL DRIVER'S LICENSE PROGRAM General § 384.107 Matter incorporated by reference. (a) Incorporation by reference. This part includes references to certain matter or materials. The text of the...

  8. 49 CFR 385.4 - Matter incorporated by reference.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 5 2011-10-01 2011-10-01 false Matter incorporated by reference. 385.4 Section... FITNESS PROCEDURES General § 385.4 Matter incorporated by reference. (a) Incorporation by reference. Part 385 includes references to certain matter or materials, as listed in paragraph (b) of this section...

  9. 49 CFR 384.107 - Matter incorporated by reference.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 5 2014-10-01 2014-10-01 false Matter incorporated by reference. 384.107 Section... COMPLIANCE WITH COMMERCIAL DRIVER'S LICENSE PROGRAM General § 384.107 Matter incorporated by reference. (a) Incorporation by reference. This part includes references to certain matter or materials. The text of the...

  10. 49 CFR 385.4 - Matter incorporated by reference.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Matter incorporated by reference. 385.4 Section... FITNESS PROCEDURES General § 385.4 Matter incorporated by reference. (a) Incorporation by reference. Part 385 includes references to certain matter or materials, as listed in paragraph (b) of this section...

  11. Critical assessment of the performance of electronic moisture analyzers for small amounts of environmental samples and biological reference materials.

    PubMed

    Krachler, M

    2001-12-01

    Two electronic moisture analyzers were critically evaluated with regard to their suitability for determining moisture in small amounts (< or = 200 mg) of various environmental matrices such as leaves, needles, soil, peat, sediments, and sewage sludge, as well as various biological reference materials. To this end, several homogeneous bulk materials were prepared which were subsequently employed for the development and optimization of all analytical procedures. The key features of the moisture analyzers included a halogen or ceramic heater and an integrated balance with a resolution of 0.1 mg, which is an essential prerequisite for obtaining precise results. Oven drying of the bulk materials in a conventional oven at 105 degrees C until constant mass served as reference method. A heating temperature of 65degrees C was found to provide accurate and precise results for almost all matrices investigated. To further improve the accuracy and precision, other critical parameters such as handling of sample pans, standby temperature, and measurement delay were optimized. Because of its ponderous heating behavior, the performance of the ceramic radiator was inferior to that of the halogen heater, which produced moisture results comparable to those obtained by oven drying. The developed drying procedures were successfully applied to the fast moisture analysis (1.4-6.3 min) of certified biological reference materials of similar provenance to the investigated the bulk materials. Moisture results for 200 mg aliquots ranged from 1.4 to 7.8% and good agreement was obtained between the recommended drying procedure for the reference materials and the electronic moisture analyzers with absolute uncertainties amounting to 0.1% and 0.2-0.3%, respectively.

  12. Re-evaluation and extension of the scope of elements in US Geological Survey Standard Reference Water Samples

    USGS Publications Warehouse

    Peart, D.B.; Antweiler, Ronald C.; Taylor, Howard E.; Roth, D.A.; Brinton, T.I.

    1998-01-01

    More than 100 US Geological Survey (USGS) Standard Reference Water Samples (SRWSs) were analyzed for numerous trace constituents, including Al, As, B, Ba, Be, Bi, Br, Cd, Cr, Co, Cu, I, Fe, Pb, Li, Mn, Mo, Ni, Rb, Sb, Se, Sr, Te, Tl, U, V, Zn and major elements (Ca, Mg, Na, SiO2, SO4, Cl) by inductively coupled plasma mass spectrometry and inductively coupled plasma atomic emission spectrometry. In addition, 15 USGS SRWSs and National Institute of Standards and Technology (NIST) standard reference material (SRM) 1641b were analyzed for mercury using cold vapor atomic fluorescence spectrometry. Also USGS SRWS Hg-7 was analyzed using isotope dilution-inductively coupled plasma mass spectrometry. The results were compared with the reported certified values of the following standard reference materials: NIST SRM 1643a, 1643b, 1643c and 1643d and National Research Council of Canada Riverine Water Reference Materials for Trace Metals SLRS-1, SLRS-2 and SLRS-3. New concentration values for trace and major elements in the SRWSs, traceable to the certified standards, are reported. Additional concentration values are reported for elements that were neither previously published for the SRWSs nor traceable to the certified reference materials. Robust statistical procedures were used that were insensitive to outliers. These data can be used for quality assurance/quality control purposes in analytical laboratories.

  13. Development of new reference material neohesperidin for quality control of dietary supplements.

    PubMed

    Gong, Ningbo; Zhang, Baoxi; Yang, Dezhi; Gao, Zhaolin; Du, Guanhua; Lu, Yang

    2015-07-01

    Neohesperidin is an important natural flavanone glycoside distributed in several citrus species. This compound is widely used as a raw material for food additives in the food industry. The request for certified reference materials (CRMs) in dietary supplements was stipulated by the National Administrative Committee for CRMs and was underpinned by the need to improve the accuracy and comparability of measurement data and to establish metrological traceability of analytical results. This paper reports the sample preparation methodology, homogeneity and stability studies, value assignment and uncertainty estimation of a new certified reference material of neohesperidin (GBW09522). Differential scanning calorimetry, coulometric titration and mass balance methods proved to be sufficiently reliable and accurate for certification purposes. The certified value of neohesperidin CRM is 994 g kg(-1) with an expanded uncertainty of 4 g kg(-1) (k = 2). The reference material described above was homogeneous and stable for 12 months at a storage temperature of 25 °C. The new CRM of neohesperidin can be used to validate analytical methods and improve the accuracy of measurement data as well as quality control of neohesperidin-related dietary supplements, foods, traditional herbs and pharmaceutical formulations. © 2014 Society of Chemical Industry.

  14. A PROCEDURE FOR ESTABLISHING TRACEABILITY OF GAS MIXTURES TO CERTAIN NATIONAL BUREAU OF STANDARDS STANDARD REFERENCE MATERIALS

    EPA Science Inventory

    This procedure includes the specifications and requirements that must be followed by gas manufacturers during the preparation of compressed cylinder gas Certified Reference Materials (CRM). A CRM is a certified gas standard prepared at a concentration that does not exceed + or - ...

  15. TWO NEW GAS STANDARDS PROGRAMS AT THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY

    EPA Science Inventory

    The EPA/NIST certified reference materials (CRM) program is being terminated and replaced with two new ones: the NIST Traceable Reference Materials (NTRM) and the Research Gas Mixture (RGM) programs. hese new programs are being implemented to provide NIST traceability to a wider ...

  16. Motion Pictures: An Update Survey of Reference Sources, 1982-1988.

    ERIC Educational Resources Information Center

    Block, Eleanor S.

    1989-01-01

    Surveys motion picture reference materials published since 1982. Materials are presented in the following categories: encyclopedic works about films, filmmakers and the industry; film criticism; people on the screen and behind it; horror, science fiction and Westerns; literature on film; catalogs and filmographies; and special collections. (70…

  17. Sourcebook for Biological Sciences.

    ERIC Educational Resources Information Center

    Troyer, Donald L.; And Others

    This is a reference book of curriculum and multimedia materials, equipment and supplies, professional references, and auxiliary resource material. This sourcebook attempts to meet the needs of the classroom biology teacher and is a direct response to the many questions and concerns of both biology teachers and those preparing to become teachers.…

  18. Recreation and Leisure: Issues for Adolescents with Chronic Illnesses and Disabilities. CYDLINE Reviews.

    ERIC Educational Resources Information Center

    Minnesota Univ., Minneapolis. National Center for Youth with Disabilities.

    This bibliography presents 162 annotated references (including bibliographic materials, training and educational materials, and programs) about issues of recreation and leisure for adolescents and young adults with chronic illnesses and disabilities. Each reference usually contains a full bibliographic citation, a brief descriptive abstract, and…

  19. 10 CFR 435.3 - Materials incorporated by reference.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 3 2014-01-01 2014-01-01 false Materials incorporated by reference. 435.3 Section 435.3 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL LOW-RISE... Renewable Energy, Building Technologies Program, Sixth Floor, 950 L'Enfant Plaza, SW., Washington, DC 20024...

  20. 10 CFR 431.75 - Materials incorporated by reference.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... available for inspection at U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy... 10 Energy 3 2013-01-01 2013-01-01 false Materials incorporated by reference. 431.75 Section 431.75 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND...

  1. 10 CFR 431.75 - Materials incorporated by reference.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... available for inspection at U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy... 10 Energy 3 2014-01-01 2014-01-01 false Materials incorporated by reference. 431.75 Section 431.75 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND...

  2. 10 CFR 435.3 - Materials incorporated by reference.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 3 2013-01-01 2013-01-01 false Materials incorporated by reference. 435.3 Section 435.3 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL LOW-RISE... Renewable Energy, Building Technologies Program, Sixth Floor, 950 L'Enfant Plaza, SW., Washington, DC 20024...

  3. 10 CFR 435.3 - Materials incorporated by reference.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 3 2012-01-01 2012-01-01 false Materials incorporated by reference. 435.3 Section 435.3 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL LOW-RISE... Renewable Energy, Building Technologies Program, Sixth Floor, 950 L'Enfant Plaza, SW., Washington, DC 20024...

  4. Biotechnology: Applications in Agriculture. Instructor Guide [and] Student Reference.

    ERIC Educational Resources Information Center

    Nevils, Aaron

    This curriculum guide incorporates the needed components to aid agriculture teachers in the implementation of the Vocational Instructional Management System in biotechnology: applications in agriculture. The guide begins with a list of the competencies/objectives found in the six units; list of references and materials; list of materials and…

  5. Anthropology: A Student's Guide to Reference Sources.

    ERIC Educational Resources Information Center

    Slavin, Suzy M., Comp.

    The guide identifies approximately 100 anthropology source materials in the reference department of McLennan Library at McGill University. It was designd to help students doing anthropological research and to illustrate the variety of materials on social and cultural anthropology in the McLennan Library. Physical anthropolgy, linguistics, and…

  6. Selected References and Aids for Teaching Agricultural Mechanics to Students of Agricultural Education.

    ERIC Educational Resources Information Center

    Mazzucco, April

    The booklet lists references and materials intended for both the student and the teacher of agricultural mechanics. The materials are grouped under nine topics: agricultural shop; metalwork and welding; agricultural machinery; agricultural power; drawing, construction, and maintenance; electricity; water management, soil and water conservation;…

  7. 49 CFR 587.5 - Incorporated materials.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... incorporated by reference. For materials subject to change, only the specific version approved by the Director of the Federal Register and specified in the regulation are incorporated. A notice of any change will... reference are listed in the Finding Aid Table found at the end of this volume of the Code of Federal...

  8. The use of digital PCR to improve the application of quantitative molecular diagnostic methods for tuberculosis.

    PubMed

    Devonshire, Alison S; O'Sullivan, Denise M; Honeyborne, Isobella; Jones, Gerwyn; Karczmarczyk, Maria; Pavšič, Jernej; Gutteridge, Alice; Milavec, Mojca; Mendoza, Pablo; Schimmel, Heinz; Van Heuverswyn, Fran; Gorton, Rebecca; Cirillo, Daniela Maria; Borroni, Emanuele; Harris, Kathryn; Barnard, Marinus; Heydenrych, Anthenette; Ndusilo, Norah; Wallis, Carole L; Pillay, Keshree; Barry, Thomas; Reddington, Kate; Richter, Elvira; Mozioğlu, Erkan; Akyürek, Sema; Yalçınkaya, Burhanettin; Akgoz, Muslum; Žel, Jana; Foy, Carole A; McHugh, Timothy D; Huggett, Jim F

    2016-08-03

    Real-time PCR (qPCR) based methods, such as the Xpert MTB/RIF, are increasingly being used to diagnose tuberculosis (TB). While qualitative methods are adequate for diagnosis, the therapeutic monitoring of TB patients requires quantitative methods currently performed using smear microscopy. The potential use of quantitative molecular measurements for therapeutic monitoring has been investigated but findings have been variable and inconclusive. The lack of an adequate reference method and reference materials is a barrier to understanding the source of such disagreement. Digital PCR (dPCR) offers the potential for an accurate method for quantification of specific DNA sequences in reference materials which can be used to evaluate quantitative molecular methods for TB treatment monitoring. To assess a novel approach for the development of quality assurance materials we used dPCR to quantify specific DNA sequences in a range of prototype reference materials and evaluated accuracy between different laboratories and instruments. The materials were then also used to evaluate the quantitative performance of qPCR and Xpert MTB/RIF in eight clinical testing laboratories. dPCR was found to provide results in good agreement with the other methods tested and to be highly reproducible between laboratories without calibration even when using different instruments. When the reference materials were analysed with qPCR and Xpert MTB/RIF by clinical laboratories, all laboratories were able to correctly rank the reference materials according to concentration, however there was a marked difference in the measured magnitude. TB is a disease where the quantification of the pathogen could lead to better patient management and qPCR methods offer the potential to rapidly perform such analysis. However, our findings suggest that when precisely characterised materials are used to evaluate qPCR methods, the measurement result variation is too high to determine whether molecular quantification of Mycobacterium tuberculosis would provide a clinically useful readout. The methods described in this study provide a means by which the technical performance of quantitative molecular methods can be evaluated independently of clinical variability to improve accuracy of measurement results. These will assist in ultimately increasing the likelihood that such approaches could be used to improve patient management of TB.

  9. Interlaboratory comparison program for nondestructive assay of prototype uranium reference materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Trahey, N.M.; Smith, M.M.; Voeks, A.M.

    The US Department of Energy (DOE), New Brunswick Laboratory (NBS), designed and administered an interlaboratory comparison program based on the measurement of NBL-produced prototype uranium nondestructive assay (NDA) reference materials for scrap and waste. The objectives of the program were to evaluate the reliability of NDA techniques as applied to nuclear safeguards materials control and accountability needs and to investigate the feasibility of providing practical NDA scrap and waste reference materials for use throughout the nuclear safeguards community. Fourteen facilities representing seven DOE contractors, four US Nuclear Regulatory Commission (NRC) licensees, one EURATOM Laboratory, and NBL, participated in this program.more » Three stable, well-characterized uranium reference materials were developed and certified for this program. Synthetic calcined ash, cellulose fiber, and ion-exchange resin simulate selected uranium scrap and waste forms which are often encountered in fabrication and recovery operations. The synthetic calcined ash represents an intermediate density inorganic matrix while the cellulose fiber and ion-exchange resin are representative of low-density organic matrices. The materials, containing from 0 to 13% uranium enriched at 93% /sup 235/U, were sealed in specially selected containers. Nineteen prototype reference samples, plus three empty containers, one to accompany each set, was circulated to the participants between August 1979 and May 1984. Triplicate measurements for /sup 235/U on each of the 19 filled containers were required. In addition, participants could opt to perform modular configuration measurements using containers from Sets IIA and IIB to simulate non-homogeneously dispersed uranium in waste containers. All data were reported to NBL for evaluation.« less

  10. Absolute Salinity, ''Density Salinity'' and the Reference-Composition Salinity Scale: present and future use in the seawater standard TEOS-10

    NASA Astrophysics Data System (ADS)

    Wright, D. G.; Pawlowicz, R.; McDougall, T. J.; Feistel, R.; Marion, G. M.

    2011-01-01

    Salinity plays a key role in the determination of the thermodynamic properties of seawater and the new TEOS-101 standard provides a consistent and effective approach to dealing with relationships between salinity and these thermodynamic properties. However, there are a number of practical issues that arise in the application of TEOS-10, both in terms of accuracy and scope, including its use in the reduction of field data and in numerical models. First, in the TEOS-10 formulation for IAPSO Standard Seawater, the Gibbs function takes the Reference Salinity as its salinity argument, denoted SR, which provides a measure of the mass fraction of dissolved material in solution based on the Reference Composition approximation for Standard Seawater. We discuss uncertainties in both the Reference Composition and the Reference-Composition Salinity Scale on which Reference Salinity is reported. The Reference Composition provides a much-needed fixed benchmark but modified reference states will inevitably be required to improve the representation of Standard Seawater for some studies. However, the Reference-Composition Salinity Scale should remain unaltered to provide a stable representation of salinity for use with the TEOS-10 Gibbs function and in climate change detection studies. Second, when composition anomalies are present in seawater, no single salinity variable can fully represent the influence of dissolved material on the thermodynamic properties of seawater. We consider three distinct representations of salinity that have been used in previous studies and discuss the connections and distinctions between them. One of these variables provides the most accurate representation of density possible as well as improvements over Reference Salinity for the determination of other thermodynamic properties. It is referred to as "Density Salinity" and is represented by the symbol SAdens; it stands out as the most appropriate representation of salinity for use in dynamical physical oceanography. The other two salinity variables provide alternative measures of the mass fraction of dissolved material in seawater. "Solution Salinity", denoted SAsoln, is the most obvious extension of Reference Salinity to allow for composition anomalies; it provides a direct estimate of the mass fraction of dissolved material in solution. "Added-Mass Salinity", denoted SAadd, is motivated by a method used to report laboratory experiments; it represents the component of dissolved material added to Standard Seawater in terms of the mass of material before it enters solution. We also discuss a constructed conservative variable referred to as "Preformed Salinity", denoted S∗, which will be useful in process-oriented numerical modelling studies. Finally, a conceptual framework for the incorporation of composition anomalies in numerical models is presented that builds from studies in which composition anomalies are simply ignored up to studies in which the influences of composition anomalies are accounted for using the results of biogeochemical models. 1TEOS-10: international Thermodynamic Equation of Seawater 2010, http://www.teos-10.org/.

  11. Absolute Salinity, "Density Salinity" and the Reference-Composition Salinity Scale: present and future use in the seawater standard TEOS-10

    NASA Astrophysics Data System (ADS)

    Wright, D. G.; Pawlowicz, R.; McDougall, T. J.; Feistel, R.; Marion, G. M.

    2010-08-01

    Salinity plays a key role in the determination of the thermodynamic properties of seawater and the new TEOS-101 standard provides a consistent and effective approach to dealing with relationships between salinity and these thermodynamic properties. However, there are a number of practical issues that arise in the application of TEOS-10, both in terms of accuracy and scope, including its use in the reduction of field data and in numerical models. First, in the TEOS-10 formulation for IAPSO Standard Seawater, the Gibbs function takes the Reference Salinity as its salinity argument, denoted SR, which provides a measure of the mass fraction of dissolved material in solution based on the Reference Composition approximation for Standard Seawater. We discuss uncertainties in both the Reference Composition and the Reference-Composition Salinity Scale on which Reference Salinity is reported. The Reference Composition provides a much-needed fixed benchmark but modified reference states will inevitably be required to improve the representation of Standard Seawater for some studies. The Reference-Composition Salinity Scale should remain unaltered to provide a stable representation of salinity for use with the TEOS-10 Gibbs function and in climate change detection studies. Second, when composition anomalies are present in seawater, no single salinity variable can fully represent the influence of dissolved material on the thermodynamic properties of seawater. We consider three distinct representations of salinity that have been used in previous studies and discuss the connections and distinctions between them. One of these variables provides the most accurate representation of density possible as well as improvements over Reference Salinity for the determination of other thermodynamic properties. It is referred to as "Density Salinity" and is represented by the symbol SAdens; it stands out as the most appropriate representation of salinity for use in dynamical physical oceanography. The other two salinity variables provide alternative measures of the mass fraction of dissolved material in seawater. "Solution Salinity", denoted SAsoln, is the most obvious extension of Reference Salinity to allow for composition anomalies; it provides a direct estimate of the mass fraction of dissolved material in solution. "Added-Mass Salinity", denoted SAadd, is motivated by a method used to report laboratory experiments; it represents the component of dissolved material added to Standard Seawater in terms of the mass of material before it enters solution. We also discuss a constructed conservative variable referred to as "Preformed Salinity", denoted S*, which will be useful in process-oriented numerical modelling studies. Finally, a conceptual framework for the incorporation of composition anomalies in numerical models is presented that builds from studies in which composition anomalies are simply ignored up to studies in which the influences of composition anomalies are accounted for using the results of biogeochemical models. 1TEOS-10: international thermodynamic equation of seawater 2010, http://www.teos-10.org.

  12. Reference Books in Special Media. Reference Circular No. 82-4.

    ERIC Educational Resources Information Center

    Library of Congress, Washington, DC. National Library Service for the Blind and Physically Handicapped.

    Based on information contained in producers' catalogs and on responses to a survey conducted by the Reference Section of the Library of Congress National Library Service (NLS) for the Blind and Physically Handicapped, this publication lists reference materials produced in braille or in large type, and sound recordings of reference works available…

  13. Laser microphone

    DOEpatents

    Veligdan, James T.

    2000-11-14

    A microphone for detecting sound pressure waves includes a laser resonator having a laser gain material aligned coaxially between a pair of first and second mirrors for producing a laser beam. A reference cell is disposed between the laser material and one of the mirrors for transmitting a reference portion of the laser beam between the mirrors. A sensing cell is disposed between the laser material and one of the mirrors, and is laterally displaced from the reference cell for transmitting a signal portion of the laser beam, with the sensing cell being open for receiving the sound waves. A photodetector is disposed in optical communication with the first mirror for receiving the laser beam, and produces an acoustic signal therefrom for the sound waves.

  14. Standardization for oxygen isotope ratio measurement - still an unsolved problem.

    PubMed

    Kornexl; Werner; Gehre

    1999-07-01

    Numerous organic and inorganic laboratory standards were gathered from nine European and North American laboratories and were analyzed for their delta(18)O values with a new on-line high temperature pyrolysis system that was calibrated using Vienna standard mean ocean water (VSMOW) and standard light Antartic precipitation (SLAP) internationally distributed reference water samples. Especially for organic materials, discrepancies between reported and measured values were high, ranging up to 2 per thousand. The reasons for these discrepancies are discussed and the need for an exact and reliable calibration of existing reference materials, as well as for the establishment of additional organic and inorganic reference materials is stressed. Copyright 1999 John Wiley & Sons, Ltd.

  15. Vehicle Assembly Building Fire Mishap Investigation Report. Volume I of V

    NASA Technical Reports Server (NTRS)

    Kight, Ira; Luciano, Steven; Stevens, Michael B.; Farley, W. Max; Collins, Bryce D.; Potterger, William C.; Levesque, Jodi

    2005-01-01

    On January 13, 2005, at approximately 1355, smoke was noticed on the 4th floor of D Tower in the Vehicle Assembly Building (VAB). Subsequently, a 911 call was made, a fire alarm pull station was activated, and the VAB was evacuated. The source of the smoke was determined to be a fire on the Low Bay M/N section roof near the Launch Control Center (LCC) Crossover. Due to the high visibility of the mishap, the KSC Center Director appointed a Mishap Investigation Board. Damage to government property was limited to the roof and a small number of ceiling tiles that were damaged by the fire fighters during the response. At the time of the mishap, there were hazardous commodities in the VAB including Solid Rocket Motors (SRMs) with open grain due to Solid Rocket Booster (SRB) igniter inspections. The Board agrees with the SGS Fire Services' theory that large amounts of smoke concentrated in the VAB D Tower and moved downward into the cable tunnel. The Board determined the proximate cause of this incident to be torching. HRI was installing a torch applied roof membrane which resulted in the ignition of combustible materials under the membrane near a wooden roof expansion joint. The torch applied roofing method is a universally accepted safe industry practice when applied to non-combustible surfaces. The combination of an open flame torch and combustible materiaLs presents an increased level of risk even with skilled applicators. The addition of high winds to this combination results in a risk the Board thinks can not be adequately mitigated. An appropriate risk assessment and analysis must be performed on the proposed roofing method to be used on high visibility facilities which represent unique national assets even when using common industry practices for repair and modification. The Board identified three root causes which contributed to or created the proximate cause and, if eliminated or modified, would have prevented the mishap: 1. Combustible materials in existing roof system 2. Wind speed and direction 3. Inadequate fire watch technique. Two contributing factors were identified which may have contributed to the occurrence but, if eliminated or modified, would not have prevented the occurrence: 1. HRI rushed to dry in and seal the roof on January 13 because heavy rain was predicted for the next day 2. No guidance on torching in windy conditions A total of 17 significant observations were noted during this investigation, which could lead to another mishap, or increase the severity of a mishap, but were not contributing factors in this mishap.

  16. Determination of the purity of pharmaceutical reference materials by 1H NMR using the standardless PULCON methodology.

    PubMed

    Monakhova, Yulia B; Kohl-Himmelseher, Matthias; Kuballa, Thomas; Lachenmeier, Dirk W

    2014-11-01

    A fast and reliable nuclear magnetic resonance spectroscopic method for quantitative determination (qNMR) of targeted molecules in reference materials has been established using the ERETIC2 methodology (electronic reference to access in vivo concentrations) based on the PULCON principle (pulse length based concentration determination). The developed approach was validated for the analysis of pharmaceutical samples in the context of official medicines control, including ibandronic acid, amantadine, ambroxol and lercanidipine. The PULCON recoveries were above 94.3% and coefficients of variation (CVs) obtained by quantification of different targeted resonances ranged between 0.7% and 2.8%, demonstrating that the qNMR method is a precise tool for rapid quantification (approximately 15min) of reference materials and medicinal products. Generally, the values were within specification (certified values) provided by the manufactures. The results were in agreement with NMR quantification using an internal standard and validated reference HPLC analysis. The PULCON method was found to be a practical alternative with competitive precision and accuracy to the classical internal reference method and it proved to be applicable to different solvent conditions. The method can be recommended for routine use in medicines control laboratories, especially when the availability and costs of reference compounds are problematic. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. 46 CFR 109.105 - Incorporation by reference.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Incorporation by reference. 109.105 Section 109.105 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS General § 109.105 Incorporation by reference. (a) Certain material is incorporated by reference...

  18. 46 CFR 109.105 - Incorporation by reference.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Incorporation by reference. 109.105 Section 109.105 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS General § 109.105 Incorporation by reference. (a) Certain material is incorporated by reference...

  19. 46 CFR 109.105 - Incorporation by reference.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Incorporation by reference. 109.105 Section 109.105 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS General § 109.105 Incorporation by reference. (a) Certain material is incorporated by reference...

  20. 46 CFR 109.105 - Incorporation by reference.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Incorporation by reference. 109.105 Section 109.105 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS General § 109.105 Incorporation by reference. (a) Certain material is incorporated by reference...

  1. 46 CFR 109.105 - Incorporation by reference.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Incorporation by reference. 109.105 Section 109.105 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS General § 109.105 Incorporation by reference. (a) Certain material is incorporated by reference...

  2. Development of a mushroom powder Certified Reference Material for calcium, arsenic, cadmium and lead measurements.

    PubMed

    Chew, Gina; Sim, Lay Peng; Ng, Sin Yee; Ding, Yi; Shin, Richard Y C; Lee, Tong Kooi

    2016-01-01

    Isotope dilution mass spectrometry and standard addition techniques were developed for the analysis of four elements (Ca, As, Cd and Pb) in a mushroom powder material. Results from the validated methods were compared to those of other national metrology institutes in the CCQM-K89 intercomparisons and the results were in excellent agreement with the reference values. The same methods were then used for the assignment of reference values to a mushroom powder Certified Reference Material (CRM). The certified values obtained for Ca, As, Cd and Pb were 1.444 ± 0.099 mg/g, 5.61 ± 0.59 mg/kg, 1.191 ± 0.079 mg/kg and 5.23 ± 0.94 mg/kg, respectively. The expanded measurement uncertainties were obtained by combining the uncertainty contributions from characterization (uchar) and between-bottle homogeneity (ubb). Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Chemical and textural characteristics of sediments at an EPA reference site for dredged material on the continental slope SW of the Farallon Islands

    USGS Publications Warehouse

    Bothner, Michael H.; Gill, P.W.; Boothman, W.S.; Taylor, B.B.; Karl, Herman A.

    1997-01-01

    A U.S. Environmental Protection Agency (EPA) reference site for dredged material has been established on the Continental Slope off San Francisco in water depths of 800-1500 m. This site, 35 km southwest of the Farallon Islands, serves as a reference for sediment testing in support of dredging and disposal at the San Francisco Deep Ocean Disposal Site (SF-DODS). An estimated 300 million cubic yards of dredged material from San Francisco Bay are expected to be discharged at this site during the next 50 years. Information from the reference site provides an additional baseline for monitoring environmental changes at the SF-DODS. This study provides sediment data on a suite of heavy metals and organic compounds which make up the EPA list of "chemicals of concern" because of their potential toxicity to marine organisms.

  4. A reassessment of the referral of Sea Turtle skulls to Osteopygis(Late Cretaceous, New Jersey, USA)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parham, James F.

    2005-01-01

    Specimens referred to Osteopygis (Late Cretaceous-Paleocene,North America) represent a chimera, a polyphyletic mixture of taxa. Theholotype of Osteopygis (AMNH 1485) and more complete referred postcranialspecimens resemble non-marine stem cryptodires ("macrobaenids"). Becausethe skull material historically referredto Osteopygis sharessynapomorphies with cheloniid sea turtles, all current workers acceptOsteopygis as a stem-cheloniid sea turtle. Multiple lines of evidencecombine to support the hypothesis that sea turtle cranial material is notattributable to Osteopygis. These lines of evidence include: phylogenetichypotheses of character evolution, the tenuous historical attribution ofspecimens, and the taphonomy of the Hornerstown Formation. Thename-bearing Osteopygis material and referred postcrania are bestconsidered Eucryptodira incertae sedis (cf.more » "Macrobaenidae"). The cranialspecimens formerly assigned to the Osteopyginae now are restricted to theclade Euclastes and those referred to Osteopygis emarginatus are herereferred to Euclastes wielandi (comb. nov.). The 'decapitation' ofOsteopygis reconciles morphological trends within stemcheloniids.« less

  5. Use of gelatin gels as a reference material for performance evaluation of meat shear force measurements

    USDA-ARS?s Scientific Manuscript database

    Establishing standards for meat tenderness based on Warner-Bratzler shear force (WBSF) is complicated by the lack of methods for certifying WBSF testing among texture systems or laboratories. The objective of this study was to determine the suitability of using gelatin gels as a reference material ...

  6. 21 CFR 320.27 - Guidelines on the design of a multiple-dose in vivo bioavailability study.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ..., DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS FOR HUMAN USE BIOAVAILABILITY AND BIOEQUIVALENCE... therapeutic moiety in the body. (2) The test product and the reference material should be administered to...) Measurement of an acute pharmacological effect. When comparison of the test product and the reference material...

  7. 21 CFR 320.27 - Guidelines on the design of a multiple-dose in vivo bioavailability study.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ..., DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS FOR HUMAN USE BIOAVAILABILITY AND BIOEQUIVALENCE... therapeutic moiety in the body. (2) The test product and the reference material should be administered to...) Measurement of an acute pharmacological effect. When comparison of the test product and the reference material...

  8. 21 CFR 320.27 - Guidelines on the design of a multiple-dose in vivo bioavailability study.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ..., DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS FOR HUMAN USE BIOAVAILABILITY AND BIOEQUIVALENCE... therapeutic moiety in the body. (2) The test product and the reference material should be administered to...) Measurement of an acute pharmacological effect. When comparison of the test product and the reference material...

  9. How to Find Out in: Engineering.

    ERIC Educational Resources Information Center

    Campana, Jean

    This library handbook is a guide for the engineering student. It lists some of the more useful materials and reference books basic to general research and gives their location in the Fogler Library at the University of Maine. Materials are listed in three categories: (1) general reference works--dictionaries, encyclopedias, and handbooks; (2)…

  10. Doorways II: Community Counselor Reference Materials. On School-Related Gender-Based Violence Prevention and Response

    ERIC Educational Resources Information Center

    US Agency for International Development, 2009

    2009-01-01

    The Doorways training program was designed by the U.S. Agency for International Development (USAID)-funded Safe Schools Program (Safe Schools) to enable teachers, community members and students to prevent and respond to school-related gender-based violence (SRGBV). This booklet, "Doorways II: Community Counselor Reference Materials on…

  11. Doorways III: Teacher Reference Materials. On School-Related Gender-Based Violence Prevention and Response

    ERIC Educational Resources Information Center

    US Agency for International Development, 2009

    2009-01-01

    The Doorways training program was designed by the U.S. Agency for International Development (USAID)-funded Safe Schools Program (Safe Schools) to enable teachers, community members and students to prevent and respond to school-related gender-based violence (SRGBV). This booklet, "Doorways III: Teacher Reference Materials on School-Related…

  12. 41 CFR 102-117.170 - What reference materials are available to ship freight?

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... are available to ship freight? 102-117.170 Section 102-117.170 Public Contracts and Property... TRANSPORTATION 117-TRANSPORTATION MANAGEMENT Shipping Freight § 102-117.170 What reference materials are available to ship freight? (a) The following is a partial list of handbooks and guides available from GSA...

  13. 41 CFR 102-117.170 - What reference materials are available to ship freight?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... are available to ship freight? 102-117.170 Section 102-117.170 Public Contracts and Property... TRANSPORTATION 117-TRANSPORTATION MANAGEMENT Shipping Freight § 102-117.170 What reference materials are available to ship freight? (a) The following is a partial list of handbooks and guides available from GSA...

  14. 41 CFR 102-117.170 - What reference materials are available to ship freight?

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... are available to ship freight? 102-117.170 Section 102-117.170 Public Contracts and Property... TRANSPORTATION 117-TRANSPORTATION MANAGEMENT Shipping Freight § 102-117.170 What reference materials are available to ship freight? (a) The following is a partial list of handbooks and guides available from GSA...

  15. 41 CFR 102-117.170 - What reference materials are available to ship freight?

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... are available to ship freight? 102-117.170 Section 102-117.170 Public Contracts and Property... TRANSPORTATION 117-TRANSPORTATION MANAGEMENT Shipping Freight § 102-117.170 What reference materials are available to ship freight? (a) The following is a partial list of handbooks and guides available from GSA...

  16. 41 CFR 102-117.170 - What reference materials are available to ship freight?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... are available to ship freight? 102-117.170 Section 102-117.170 Public Contracts and Property... TRANSPORTATION 117-TRANSPORTATION MANAGEMENT Shipping Freight § 102-117.170 What reference materials are available to ship freight? (a) The following is a partial list of handbooks and guides available from GSA...

  17. Braille Literacy: Resources for Instruction, Writing Equipment, and Supplies. NLS Reference Circulars

    ERIC Educational Resources Information Center

    Peaco, Freddie L., Comp.

    2004-01-01

    This reference circular lists instructional materials, supplies, and equipment currently available for learning braille, and cites sources about braille literacy. The resources given are intended to assist sighted individuals who are interested in learning braille or want to transcribe print materials into braille; instructors who teach braille;…

  18. APEX (Air Pollution Exercise) Volume 20: Reference Materials.

    ERIC Educational Resources Information Center

    Environmental Protection Agency, Research Triangle Park, NC. Office of Manpower Development.

    The Reference Materials Manual is part of a set of 21 manuals (AA 001 009-001 029) used in APEX (Air Pollution Exercise), a computerized college and professional level "real world" game simulation of a community with urban and rural problems, industrial activities, and air pollution difficulties. For the purposes of the gaming exercise, APEX…

  19. New Ca-Tims and La-Icp Analyses of GJ-1, Plesovice, and FC1 Reference Materials

    NASA Astrophysics Data System (ADS)

    Feldman, J. D.; Möller, A.; Walker, J. D.

    2014-12-01

    Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) U-Pb zircon geochronology relies on external reference standards to monitor and correct for different mass fractionation effects and instrument drift. Common zircon reference materials used within the community, including the KU Isotope Geochemistry Laboratory, are GJ-1 (207Pb/206Pb age: 608.53 +/- 0.37Ma; Jackson et al., 2004), Plesovice (337.13 +/- 0.37 Ma; Slama et al., 2008), and FC-1 (1099.0 +/-0.6 Ma; Paces and Miller, 1993). The age distribution of zircon reference material varies slightly from sample fraction to sample fraction, and the published results for GJ-1 are slightly discordant. As a result, using the published data for the distributed standard splits can lead to small systematic variations when comparing datasets from different labs, and more high precision data are needed to evaluate potential inhomogeneity of sample splits used in different laboratories. Here we characterize these reference materials with cathodoluminescence, LA-ICP-MS traverses across grains, and high precision CA-TIMS to better constrain the ages and assess zoning of these standards, and present the data for comparison with other laboratories. Reducing systematic error by dating our own reference material lends confidence to our analyses and allows for inter-laboratory age reproducibility of unknowns. Additionally, the reduction in propagated uncertainties (especially in GJ-1, for which both the red and yellow variety will be analyzed) will be used to improve long-term reproducibility, comparisons between samples of similar age, detrital populations and composite pluton zircons. Jackson, S.E., et al., 2004, Chemical Geology, v. 211, p. 47-69. Paces, J.B. & Miller, J.D., 1993, Journal of Geophysical Research, v. 80, p. 13997-14013. Slama, J., et al., 2008, Chemical Geology, v. 249. p. 1-35.

  20. Development of a genomic DNA reference material panel for myotonic dystrophy type 1 (DM1) genetic testing.

    PubMed

    Kalman, Lisa; Tarleton, Jack; Hitch, Monica; Hegde, Madhuri; Hjelm, Nick; Berry-Kravis, Elizabeth; Zhou, Lili; Hilbert, James E; Luebbe, Elizabeth A; Moxley, Richard T; Toji, Lorraine

    2013-07-01

    Myotonic dystrophy type 1 (DM1) is caused by expansion of a CTG triplet repeat in the 3' untranslated region of the DMPK gene that encodes a serine-threonine kinase. Patients with larger repeats tend to have a more severe phenotype. Clinical laboratories require reference and quality control materials for DM1 diagnostic and carrier genetic testing. Well-characterized reference materials are not available. To address this need, the Centers for Disease Control and Prevention-based Genetic Testing Reference Material Coordination Program, in collaboration with members of the genetic testing community, the National Registry of Myotonic Dystrophy and Facioscapulohumeral Muscular Dystrophy Patients and Family Members, and the Coriell Cell Repositories, has established and characterized cell lines from patients with DM1 to create a reference material panel. The CTG repeats in genomic DNA samples from 10 DM1 cell lines were characterized in three clinical genetic testing laboratories using PCR and Southern blot analysis. DMPK alleles in the samples cover four of five DM1 clinical categories: normal (5 to 34 repeats), mild (50 to 100 repeats), classical (101 to 1000 repeats), and congenital (>1000 repeats). We did not identify or establish Coriell cell lines in the premutation range (35 to 49 repeats). These samples are publicly available for quality control, proficiency testing, test development, and research and should help improve the accuracy of DM1 testing. Copyright © 2013 American Society for Investigative Pathology. Published by Elsevier Inc. All rights reserved.

  1. 46 CFR 62.05-1 - Incorporation by reference.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Incorporation by reference. 62.05-1 Section 62.05-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING VITAL SYSTEM AUTOMATION Reference Specifications § 62.05-1 Incorporation by reference. (a) Certain material is...

  2. 41 CFR 302-17.13 - Source references.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 41 Public Contracts and Property Management 4 2010-07-01 2010-07-01 false Source references. 302... references. The following references or publications have been used as source material for this part. (a...) Internal Revenue Service Publication 521, “Moving Expenses.” (c) Internal Revenue Service, Circular E...

  3. Quarry waste management and recovery: first results connected to Carrara marble ravaneti (Italy)

    NASA Astrophysics Data System (ADS)

    Antonella Dino, Giovanna; Chiappino, Claudia; Rossetti, Piergiorgio

    2017-04-01

    Quarry waste (QW) represents a huge economic and environmental issue, due to loss of resources and to economic and environmental costs connected to waste management and landfilling activities. In many cases, valuable Raw Materials (RM) and Secondary Raw Materials (SRM) can be supplied by enhancing the QW recovery. In Italy large amounts of QW have been and still are dumped: such materials, if their quality (chemical, mineralogical, physical characteristics) and quantity are adequate, and if the impacts connected to their management are positive, can represent a valuable resource for SRM exploitation. Several dimension stone quarries have been and are interested by researches as for QW exploitation. Some researches show positive results, which are the basis for QW recovery (both from waste streams and from quarry dumps exploitation): a noticeable example is represented by Carrara marble waste. The Carrara quarry basin is characterized by ca. one hundred quarries for colored and white marble exploitation. The waste production can be summarized in: 80 Mm3 waste present in old quarry dumps (Ravaneti) and 3 Mm3/y of waste stream from quarrying activities. At present only 0.5 Mm3/y of QW is exploited for SRM production, causing a huge loss of resource. This has been the background for a preliminary research, on Carrara marble Ravaneti characterization, which was carried out thanks to the close cooperation between University of Torino, Società Apuana Marmi srl, and SET srl. In 2015, two QW dumping areas, Calocara and Lorano, were selected as representative for sampling activities. Three main sample categories were individuated based on granulometry (0.5-4 mm, 0-25 mm, 0-150 mm) to be characterized (size distribution, density, Atterberg limits, Los Angeles test, freezing and heat tests, flat and shape indexes, geochemistry, mineralogy). The results obtained are promising: the physical characterization shows an attitude for Carrara QW to be recovered as crushed materials for embankments and armour stone. Furthermore, the mineralogical and geochemical analyses show that these materials, being composed of nearly pure CaCO3, could find a proper application in high value products, as filler for paper, rubber, paint, plastic, etc. These data need to be confirmed by other analyses, thus a systematic characterization of QW present in the different quarry dumps is going to be programmed. R&D is strategic to solve problems connected to QW and landscape management. The cooperation between private Companies, Research Centers and Local Authorities is fundamental to reach the target, in terms of experimentation of new products (for civil works and infrastructure, building industry, agronomy, high-tech, etc.). Furthermore, if the stone industry aims at guaranteeing the systematic and convenient SRM recovery from QW, a change in exploitation and working activities has to be planned (eg. selection of the potential SRMs; dedicated stock areas for selected SRM; proper treatments depending on the kinds of reuse; treatment-activity protocols to produce each new product, etc.).

  4. Oxygen isotopes in nitrate: New reference materials for 18O:17O:16O measurements and observations on nitrate-water equilibration

    USGS Publications Warehouse

    Böhlke, J.K.; Mroczkowski, S.J.; Coplen, T.B.

    2003-01-01

    Despite a rapidly growing literature on analytical methods and field applications of O isotope-ratio measurements of NO3− in environmental studies, there is evidence that the reported data may not be comparable because reference materials with widely varying δ18O values have not been readily available. To address this problem, we prepared large quantities of two nitrate salts with contrasting O isotopic compositions for distribution as reference materials for O isotope-ratio measurements: USGS34 (KNO3) with low δ18O and USGS35 (NaNO3) with high δ18O and ‘mass-independent’ δ17O. The procedure used to produce USGS34 involved equilibration of HNO3 with 18O-depleted meteoric water. Nitric acid equilibration is proposed as a simple method for producing laboratory NO3− reference materials with a range of δ18O values and normal (mass-dependent) 18O:17O:16O variation. Preliminary data indicate that the equilibrium O isotope-fractionation factor (α) between [NO3−] and H2O decreases with increasing temperature from 1.0215 at 22°C to 1.0131 at 100°C. USGS35 was purified from the nitrate ore deposits of the Atacama Desert in Chile and has a high 17O:18O ratio owing to its atmospheric origin. These new reference materials, combined with previously distributed NO3− isotopic reference materials IAEA-N3 (=IAEA-NO-3) and USGS32, can be used to calibrate local laboratory reference materials for determining offset values, scale factors, and mass-independent effects on N and O isotope-ratio measurements in a wide variety of environmental NO3− samples. Preliminary analyses yield the following results (normalized with respect to VSMOW and SLAP, with reproducibilities of ±0.2–0.3‰, 1σ): IAEA-N3 has δ18O = +25.6‰ and δ17O = +13.2‰; USGS32 has δ18O = +25.7‰; USGS34 has δ18O = −27.9‰ and δ17O = −14.8‰; and USGS35 has δ18O = +57.5‰ and δ17O = +51.5‰.

  5. One Novel Multiple-Target Plasmid Reference Molecule Targeting Eight Genetically Modified Canola Events for Genetically Modified Canola Detection.

    PubMed

    Li, Zhuqing; Li, Xiang; Wang, Canhua; Song, Guiwen; Pi, Liqun; Zheng, Lan; Zhang, Dabing; Yang, Litao

    2017-09-27

    Multiple-target plasmid DNA reference materials have been generated and utilized as good substitutes of matrix-based reference materials in the analysis of genetically modified organisms (GMOs). Herein, we report the construction of one multiple-target plasmid reference molecule, pCAN, which harbors eight GM canola event-specific sequences (RF1, RF2, MS1, MS8, Topas 19/2, Oxy235, RT73, and T45) and a partial sequence of the canola endogenous reference gene PEP. The applicability of this plasmid reference material in qualitative and quantitative PCR assays of the eight GM canola events was evaluated, including the analysis of specificity, limit of detection (LOD), limit of quantification (LOQ), and performance of pCAN in the analysis of various canola samples, etc. The LODs are 15 copies for RF2, MS1, and RT73 assays using pCAN as the calibrator and 10 genome copies for the other events. The LOQ in each event-specific real-time PCR assay is 20 copies. In quantitative real-time PCR analysis, the PCR efficiencies of all event-specific and PEP assays are between 91% and 97%, and the squared regression coefficients (R 2 ) are all higher than 0.99. The quantification bias values varied from 0.47% to 20.68% with relative standard deviation (RSD) from 1.06% to 24.61% in the quantification of simulated samples. Furthermore, 10 practical canola samples sampled from imported shipments in the port of Shanghai, China, were analyzed employing pCAN as the calibrator, and the results were comparable with those assays using commercial certified materials as the calibrator. Concluding from these results, we believe that this newly developed pCAN plasmid is one good candidate for being a plasmid DNA reference material in the detection and quantification of the eight GM canola events in routine analysis.

  6. Characterization of NIES CRM No. 23 Tea Leaves II for the determination of multielements.

    PubMed

    Mori, Ikuko; Ukachi, Miyuki; Nagano, Kimiyo; Ito, Hiroyasu; Yoshinaga, Jun; Nishikawa, Masataka

    2010-05-01

    A candidate environmental certified reference material (CRM) for the determination of multielements in tea leaves and materials of similar matrix, NIES CRM No. 23 Tea Leaves II, has been developed and characterized by the National Institute for Environmental Studies (NIES), Japan. The origin of the material was tea leaves, which were ground, sieved through a 106-microm mesh, homogenized, and then subdivided into amber glass bottles. The results of homogeneity and stability tests indicated that the material was sufficiently homogeneous and stable for use as a reference material. The property values of the material were statistically determined based on chemical analyses by a network of laboratories using a wide range of methods. Sixteen laboratories participated in the characterization, and nine certified values and five reference values were obtained. These property values of the candidate CRM, which are expressed as mass fractions, were close to the median and/or mean values of the mass fractions of elements in various tea products. The candidate CRM is appropriate for use in analytical quality control and in the evaluation of methods used in the analysis of tea and materials of similar matrix.

  7. 77 FR 60935 - Hazardous Materials: Minor Editorial Corrections and Clarifications (RRR)

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-05

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration 49 CFR Parts... Materials: Minor Editorial Corrections and Clarifications (RRR) AGENCY: Pipeline and Hazardous Materials... material. (a) * * * (3) * * * Source and name of material 49 CFR reference * * * * * * * ISO 9809-1: Gas...

  8. Measurements of plutonium, 237Np, and 137Cs in the BCR 482 lichen reference material

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lavelle, Kevin B.; Miller, Jeffrey L.; Hanson, Susan K.

    Select anthropogenic radionuclides were measured in lichen reference material, BCR 482. This material was originally collected in Axalp, Switzerland in 1991 and is composed of the epiphytic lichen Pseudevernia furfuracea. Samples from three separate bottles of BCR 482 were analyzed for uranium, neptunium, and plutonium isotopes by inductively coupled plasma mass spectrometry (ICP-MS) and analyzed for cesium-137 by gamma-ray spectrometry. The isotopic composition of the radionuclides measured in BCR 482 suggests contributions from both global fallout resulting from historical nuclear weapons testing and more volatile materials released following the Chernobyl accident.

  9. Measurements of plutonium, 237Np, and 137Cs in the BCR 482 lichen reference material

    DOE PAGES

    Lavelle, Kevin B.; Miller, Jeffrey L.; Hanson, Susan K.; ...

    2015-10-01

    Select anthropogenic radionuclides were measured in lichen reference material, BCR 482. This material was originally collected in Axalp, Switzerland in 1991 and is composed of the epiphytic lichen Pseudevernia furfuracea. Samples from three separate bottles of BCR 482 were analyzed for uranium, neptunium, and plutonium isotopes by inductively coupled plasma mass spectrometry (ICP-MS) and analyzed for cesium-137 by gamma-ray spectrometry. The isotopic composition of the radionuclides measured in BCR 482 suggests contributions from both global fallout resulting from historical nuclear weapons testing and more volatile materials released following the Chernobyl accident.

  10. HOW OLD IS IT? - 241PU/241AM NUCLEAR FORENSIC CHRONOLOGY REFERENCE MATERIALS

    PubMed Central

    Fitzgerald, Ryan; Inn, Kenneth G.W.; Horgan, Christopher

    2018-01-01

    One material attribute for nuclear forensics is material age. 241Pu is almost always present in uranium- and plutonium-based nuclear weapons, which pose the greatest threat to our security. The in-growth of 241Am due to the decay of 241Pu provides an excellent chronometer of the material. A well-characterized 241Pu/241Am standard is needed to validate measurement capability, as a basis for between-laboratory comparability, and as material for verifying laboratory performance. This effort verifies the certification of a 38 year old 241Pu Standard Reference Material (SRM4340) through alpha-gamma anticoincidence counting, and also establishes the separation date to two weeks of the documented date. PMID:29720779

  11. Determination of the platinum - Group elements (PGE) and gold (Au) in manganese nodule reference samples by nickel sulfide fire-assay and Te coprecipitation with ICP-MS

    USGS Publications Warehouse

    Balaram, V.; Mathur, R.; Banakar, V.K.; Hein, J.R.; Rao, C.R.M.; Gnaneswara, Rao T.; Dasaram, B.

    2006-01-01

    Platinum group elements (PGE) and Au data in polymetallic oceanic ferromanganese nodule reference samples and crust samples obtained by inductively coupled plasma mass spectrometry (ICP-MS), after separation and pre-concentration by nickel sulfide fire-assay and Te coprecipitation, are presented. By optimizing several critical parameters such as flux composition, matrix matching calibration, etc., best experimental conditions were established to develop a method suitable for routine analysis of manganese nodule samples for PGE and Au. Calibrations were performed using international PGE reference materials, WMG-1 and WMS-1. This improved procedure offers extremely low detection limits in the range of 0.004 to 0.016 ng/g. The results obtained in this study for the reference materials compare well with previously published data wherever available. New PGE data arc also provided on some international manganese nodule reference materials. The analytical methodology described here can be used for the routine analysis of manganese nodule and crust samples in marine geochemical studies.

  12. An automated protocol for performance benchmarking a widefield fluorescence microscope.

    PubMed

    Halter, Michael; Bier, Elianna; DeRose, Paul C; Cooksey, Gregory A; Choquette, Steven J; Plant, Anne L; Elliott, John T

    2014-11-01

    Widefield fluorescence microscopy is a highly used tool for visually assessing biological samples and for quantifying cell responses. Despite its widespread use in high content analysis and other imaging applications, few published methods exist for evaluating and benchmarking the analytical performance of a microscope. Easy-to-use benchmarking methods would facilitate the use of fluorescence imaging as a quantitative analytical tool in research applications, and would aid the determination of instrumental method validation for commercial product development applications. We describe and evaluate an automated method to characterize a fluorescence imaging system's performance by benchmarking the detection threshold, saturation, and linear dynamic range to a reference material. The benchmarking procedure is demonstrated using two different materials as the reference material, uranyl-ion-doped glass and Schott 475 GG filter glass. Both are suitable candidate reference materials that are homogeneously fluorescent and highly photostable, and the Schott 475 GG filter glass is currently commercially available. In addition to benchmarking the analytical performance, we also demonstrate that the reference materials provide for accurate day to day intensity calibration. Published 2014 Wiley Periodicals Inc. Published 2014 Wiley Periodicals Inc. This article is a US government work and, as such, is in the public domain in the United States of America.

  13. 17 CFR 240.12b-23 - Incorporation by reference.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... registration statement or report by reference, or copies of the pertinent pages of the document containing such... clearly identified in the reference by page, paragraph, and caption or otherwise. Where only certain pages... material is taken shall be clearly identified in the reference. An express statement that the specified...

  14. 17 CFR 240.12b-23 - Incorporation by reference.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... registration statement or report by reference, or copies of the pertinent pages of the document containing such... clearly identified in the reference by page, paragraph, and caption or otherwise. Where only certain pages... material is taken shall be clearly identified in the reference. An express statement that the specified...

  15. Reference Materials and Services for a Small Hospital Library. 5th Revised Edition.

    ERIC Educational Resources Information Center

    Kesti, Julie, Comp.; Graham, Elaine, Comp.

    This manual suggests and describes recommended reference services and sources for a small hospital library. Focusing on reference services, the first section includes information on ready-reference services; bibliographic search services, including taking and processing a request for a bibliography, National Library of Medicine literature…

  16. Evaluation of Method-Specific Extraction Variability for the Measurement of Fatty Acids in a Candidate Infant/Adult Nutritional Formula Reference Material.

    PubMed

    Place, Benjamin J

    2017-05-01

    To address community needs, the National Institute of Standards and Technology has developed a candidate Standard Reference Material (SRM) for infant/adult nutritional formula based on milk and whey protein concentrates with isolated soy protein called SRM 1869 Infant/Adult Nutritional Formula. One major component of this candidate SRM is the fatty acid content. In this study, multiple extraction techniques were evaluated to quantify the fatty acids in this new material. Extraction methods that were based on lipid extraction followed by transesterification resulted in lower mass fraction values for all fatty acids than the values measured by methods utilizing in situ transesterification followed by fatty acid methyl ester extraction (ISTE). An ISTE method, based on the identified optimal parameters, was used to determine the fatty acid content of the new infant/adult nutritional formula reference material.

  17. Constraints on transportation of reagents, reference materials and samples, difficulties and possible solutions: a user's perspective.

    PubMed

    Blanchard, P C

    2006-01-01

    The air transportation of infectious materials is regulated by international air transport associations and based on United Nations Model regulations which have become more practical in addressing animal disease agents. However, individual countries' import and interstate requirements determine what materials can be imported and transported, and this approval process can be long, resulting in delays in organism confirmation, use of international OIE and other reference laboratories, and acquisition of reference materials, proficiency test panels, and reagents for performing necessary testing. Delays can be prevented for permits that are required for the routine work performed by a laboratory through the use of comprehensive and annually renewed permits. This process, however, does not address new and exotic agents where time is critical to an effective emergency response. This paper suggests actions by both the OIE and regulatory authorities which can assist in streamlining and expediting the permit process.

  18. Aluminium-gold reference material for the k0-standardisation of neutron activation analysis

    NASA Astrophysics Data System (ADS)

    Ingelbrecht, C.; Peetermans, F.; De Corte, F.; De Wispelaere, A.; Vandecasteele, C.; Courtijn, E.; D'Hondt, P.

    1991-05-01

    Gold is an excellent comparator material for the k0-standardisation of neutron activation analysis because of its convenient and well defined nuclear properties. The most suitable form for a reference material is a dilute aluminium-gold alloy, for which the self-shielding effect for neutrons is small. Castings of composition Al-0.1 wt.% Au were prepared by crucible-less levitation melting, which gives close control of ingot composition with minimal contamination of the melt. The alloy composition was checked using induction-coupled plasma source emission spectrometry. The homogeneity of the alloy was measured by neutron activation analysis and a relative standard deviation of the gold content of 0.30% was found (10 mg samples). Metallography revealed a homogeneous distribution of AuAl 2 particles. The alloy was certified as Reference Material CBNM-530, with certified gold mass fraction 0.100±0.002 wt.%.

  19. PDQ: Planning and Development of Quality Services in the Schools, Instructional Guide, Student Manual and Reference Materials.

    ERIC Educational Resources Information Center

    Wright, Sandra Raymore

    The instructional guide, student manual, and reference materials were developed by the PDQ Project, Planning and Development of Quality Services in the Schools, an effort by the American Speech-Language-Hearing Association to provide public school personnel working with communication disordered children with information and training related to…

  20. Analysis of standard reference materials by absolute INAA

    NASA Astrophysics Data System (ADS)

    Heft, R. E.; Koszykowski, R. F.

    1981-07-01

    Three standard reference materials: flyash, soil, and ASI 4340 steel, are analyzed by a method of absolute instrumental neutron activation analysis. Two different light water pool-type reactors were used to produce equivalent analytical results even though the epithermal to thermal flux ratio in one reactor was higher than that in the other by a factor of two.

Top