Sample records for reference method frm

  1. 40 CFR 53.2 - General requirements for a reference method determination.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) Manual methods—(1) Sulfur dioxide (SO 2 ) and lead. For measuring SO2 and lead, appendices A and G of part 50 of this chapter specify unique manual FRM for measuring these pollutants. Except as provided in § 53.16, other manual methods for SO2 and lead will not be considered for FRM determinations under this...

  2. Field Evaluation of Portable and Central Site PM Samplers Emphasizing Additive and Differential Mass Concentration Estimates

    EPA Science Inventory

    The US Environmental Protection Agency (EPA) published a National Ambient Air Quality Standard (NAAQS) and the accompanying Federal Reference Method (FRM) for PM10 in 1987. The EPA revised the particle standards and FRM in 1997 to include PM2.5. In 2005, EPA...

  3. IMPROVED TEMPERATURE STABILITY OF SULFUR DIOXIDE SAMPLES COLLECTED BY THE FEDERAL REFERENCE METHOD

    EPA Science Inventory

    This report describes an examination of the reagents present in the SO2 Federal Reference Method (FRM) to determine if any change in reagent concentration or condition could bring about substantial, if not complete, retardation of the effect of temperature on the stability of col...

  4. PRELIMINARY RESULTS OF EPA'S PERFORMANCE EVALUATION OF FEDERAL REFERENCE METHODS AND FEDERAL EQUIVALENT METHODS FOR COARSE PARTICULATE MATTER

    EPA Science Inventory

    The main objective of this study is to evaluate the performance of sampling methods for potential use as a Federal Reference Method (FRM) capable of providing an estimate of coarse particle (PMc: particulate matter with an aerodynamic diameter between 2.5 µm and 10 µm) ...

  5. Reference and Equivalent Methods Used to Measure National Ambient Air Quality Standards (NAAQS) Criteria Air Pollutants - Volume I

    EPA Science Inventory

    There are a number of Federal Reference Method (FRM) and Federal Equivalent Method (FEM) systems used to monitor the six criteria air pollutants (Lead [Pb], Carbon Monoxide [CO], Sulfur Dioxide [SO2], Nitrogen Dioxide [NO2], Ozone [O3], Particulate Matter [PM]) to determine if an...

  6. Evaluation of Elm and Speck Sensors

    EPA Science Inventory

    Particulate matter (PM) is a pollutant of high public interest regulated by national ambient air quality standards (NAAQS) using Federal Reference Method (FRM) and Federal Equivalent Method (FEM) instrumentation identified for environmental monitoring. The US EPA has been evaluat...

  7. Evaluation of Field-deployed Low Cost PM Sensors

    EPA Science Inventory

    Background Particulate matter (PM) is a pollutant of high public interest regulated by national ambient air quality standards (NAAQS) using federal reference method (FRM) and federal equivalent method (FEM) instrumentation identified for environmental monitoring. PM is present i...

  8. Performance of the Proposed New Federal Reference Methods for Measuring Ozone Concentrations in Ambient Air

    EPA Science Inventory

    The current Federal Reference Method (FRM) for measuring concentrations of ozone in ambient air, described in EPA regulations at 40 CFR Part 50, Appendix D, is based on the dry, gas-phase, chemiluminescence reaction between ethylene (C2H4) and any ozone (O

  9. PM: RESEARCH METHODS FOR PM TOXIC COMPOUNDS - PARTICLE METHODS EVALUATION AND DEVELOPMENT

    EPA Science Inventory

    The Federal Reference Method (FRM) for Particulate Matter (PM) developed by EPA's National Exposure Research Laboratory (NERL) forms the backbone of the EPA's national monitoring strategy. It is the measurement that defines attainment of the National Ambient Air Quality Standard...

  10. Ambient intercomparison of direct and indirect methods for ambient nitrogen dioxide

    EPA Science Inventory

    AbstractRecent advances in measurement techniques for nitrogen dioxide (NO2), along with known interferences in the current Federal Reference Method (FRM) have created the need for NO2 measurement method research within EPA’s Office of Research and Development. Current meth...

  11. Integrating Sensor Monitoring Technology into the Current Air Pollution Regulatory Support Paradigm: Practical Considerations

    EPA Science Inventory

    The US Environmental Protection Agency (EPA) along with state, local, and tribal governments operate Federal Reference Method (FRM) and Federal Equivalent Method (FEM) instruments to assess compliance with US air pollution standards designed to protect human and ecosystem health....

  12. Low-Cost Sensor POD Design Considerations

    EPA Science Inventory

    Public concern about air quality is growing in communities around the globe as citizens learn more about the potential health effects of the air they breathe. Air quality monitoring has often been restricted to organizations administering Federal Reference Method (FRM) or Federal...

  13. Low-Cost Sensor POD Design Considerations

    EPA Science Inventory

    Public concern about air quality is growing in communities around the globe as citizens learn more about the potential health effects of the air they breathe.1 Air quality monitoring has often been restricted to organizations administering Federal Reference Method (FRM) or Federa...

  14. 40 CFR 53.2 - General requirements for a reference method determination.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... part. Further, FRM samplers must be manufactured in an ISO 9001-registered facility, as defined in § 53... manufactured in an ISO 9001-registered facility, as defined in § 53.1 and as set forth in § 53.51. (b...

  15. LABORATORY AND FIELD EVALUATION OF CRYSTALLIZED DOW 704 OIL ON THE PERFORMANCE OF THE WINS PM2.5 FRACTIONATOR

    EPA Science Inventory

    Subsequent to the 1997 promulgation of the Federal Reference Method (FRM) for monitoring PM2.5 in ambient air, the United States Environmental Protection Agency (USEPA) received reports that the Dow 704 diffusion oil used in the method's WINS fractionator would occasionally cry...

  16. DETERMINING COARSE PARTICULATE MATTER CONCENTRATIONS: A PERFORMANCE EVALUATION OF CANDIDATE METHODOLOGIES UNDER WINTERTIME CONDITIONS

    EPA Science Inventory

    The main objective of this study is to evaluate the performance of sampling methods for potential use as a Federal Reference Method (FRM) capable of providing an estimate of coarse particle (PMc: particulate matter with an aerodynamic diameter between 2.5 um and 10 um) mass con...

  17. Evaluation and Comparison of Chemiluminescence and UV Photometric Methods for Measuring Ozone Concentrations in Ambient Air

    EPA Science Inventory

    The current Federal Reference Method (FRM) for measuring concentrations of ozone in ambient air is based on the dry, gas-phase, chemiluminescence reaction between ethylene (C2H4) and any ozone (O3) that may be p...

  18. A Comparison of Four Gravimetric Fine Particle Sampling Methods.

    PubMed

    Yanosky, Jeff D; Maclntosh, David L

    2001-06-01

    A study was conducted to compare four gravimetric methods of measuring fine particle (PM 2.5 ) concentrations in air: the BGI, Inc. PQ200 Federal Reference Method PM 2.5 (FRM) sampler; the Harvard-Marple Impactor (HI); the BGI, Inc. GK2.05 KTL Respirable/Thoracic Cyclone (KTL); and the AirMetrics MiniVol (MiniVol). Pairs of FRM, HI, and KTL samplers and one MiniVol sampler were collocated and 24-hr integrated PM 2.5 samples were collected on 21 days from January 6 through April 9, 2000. The mean and standard deviation of PM 2.5 levels from the FRM samplers were 13.6 and 6.8 μg/m 3 , respectively. Significant systematic bias was found between mean concentrations from the FRM and the MiniVol (1.14 μg/m 3 , p = 0.0007), the HI and the MiniVol (0.85 μg/m 3 , p = 0.0048), and the KTL and the MiniVol (1.23 μg/m 3 , p = 0.0078) according to paired t test analyses. Linear regression on all pairwise combinations of the sampler types was used to evaluate measurements made by the samplers. None of the regression intercepts was significantly different from 0, and only two of the regression slopes were significantly different from 1, that for the FRM and the MiniVol [β 1 = 0.91, 95% CI (0.83-0.99)] and that for the KTL and the MiniVol [ = 0.88, 95% CI (0.78-0.98)]. Regression R 2 terms were 0.96 or greater between all pairs of samplers, and regression root mean square error terms (RMSE) were 1.65 μg/m 3 or less. These results suggest that the MiniVol will underestimate measurements made by the FRM, the HI, and the KTL by an amount proportional to PM 2.5 concentration. Nonetheless, these results indicate that all of the sampler types are comparable if ~10% variation on the mean levels and on individual measurement levels is considered acceptable and the actual concentration is within the range of this study (5-35 μg/m 3 ).

  19. A comparison of four gravimetric fine particle sampling methods.

    PubMed

    Yanosky, J D; MacIntosh, D L

    2001-06-01

    A study was conducted to compare four gravimetric methods of measuring fine particle (PM2.5) concentrations in air: the BGI, Inc. PQ200 Federal Reference Method PM2.5 (FRM) sampler; the Harvard-Marple Impactor (HI); the BGI, Inc. GK2.05 KTL Respirable/Thoracic Cyclone (KTL); and the AirMetrics MiniVol (MiniVol). Pairs of FRM, HI, and KTL samplers and one MiniVol sampler were collocated and 24-hr integrated PM2.5 samples were collected on 21 days from January 6 through April 9, 2000. The mean and standard deviation of PM2.5 levels from the FRM samplers were 13.6 and 6.8 microg/m3, respectively. Significant systematic bias was found between mean concentrations from the FRM and the MiniVol (1.14 microg/m3, p = 0.0007), the HI and the MiniVol (0.85 microg/m3, p = 0.0048), and the KTL and the MiniVol (1.23 microg/m3, p = 0.0078) according to paired t test analyses. Linear regression on all pairwise combinations of the sampler types was used to evaluate measurements made by the samplers. None of the regression intercepts was significantly different from 0, and only two of the regression slopes were significantly different from 1, that for the FRM and the MiniVol [beta1 = 0.91, 95% CI (0.83-0.99)] and that for the KTL and the MiniVol [beta1 = 0.88, 95% CI (0.78-0.98)]. Regression R2 terms were 0.96 or greater between all pairs of samplers, and regression root mean square error terms (RMSE) were 1.65 microg/m3 or less. These results suggest that the MiniVol will underestimate measurements made by the FRM, the HI, and the KTL by an amount proportional to PM2.5 concentration. Nonetheless, these results indicate that all of the sampler types are comparable if approximately 10% variation on the mean levels and on individual measurement levels is considered acceptable and the actual concentration is within the range of this study (5-35 microg/m3).

  20. Evaluation of the TEOM method for measurement of ambient particulate mass in urban areas.

    PubMed

    Allen, G; Sioutas, C; Koutrakis, P; Reiss, R; Lurmann, F W; Roberts, P T

    1997-06-01

    Increased interest in the health effects of ambient particulate mass (PM) has focused attention on the evaluation of existing mass measurement methodologies and the definition of PM in ambient air. The Rupprecht and Patashnick Tapered Element Oscillating MicroBalance (TEOM) method for PM is compared with time-integrated gravimetric (manual) PM methods in large urban areas during different seasons. Comparisons are conducted for both PM10 and PM2.5 concentrations. In urban areas, a substantial fraction of ambient PM can be semi-volatile material. A larger fraction of this component of PM10 may be lost from the TEOM-heated filter than the Federal Reference Method (FRM). The observed relationship between TEOM and FRM methods varied widely among sites and seasons. In East Coast urban areas during the summer, the methods were highly correlated with good agreement. In the winter, correlation was somewhat lower, with TEOM PM concentrations generally lower than the FRM. Rubidoux, CA, and two Mexican sites (Tlalnepantla and Merced) had the highest levels of PM10 and the largest difference between TEOM and manual methods. PM2.5 data from collocation of 24-hour manual samples with the TEOM are also presented. As most of the semi-volatile PM is in the fine fraction, differences between these methods are larger for PM2.5 than for PM10.

  1. DETERMINING COARSE PARTICULATE MATTER CONCENTRATIONS: A PERFORMANCE EVALUATION OF CANDIDATE METHODOLOGIES - STUDY DESIGN AND RESULTS FROM THE RTP EQUIPMENT SHAKEDOWN

    EPA Science Inventory

    The main objective of this study is to evaluate the performance of candidate sampling methods for potential use as a Federal Reference Method (FRM) capable of providing an estimate of coarse particle (PMc: particulate matter with an aerodynamic diameter between 2.5 um and 10 um...

  2. Review of Federal Reference Method for Ozone: Nitric Oxide-Chemiluminescence

    EPA Science Inventory

    •The proposed new FRM measurement principle for ozone is based on quantitative measurement of the chemiluminescence emission from the gas-phase reaction of ozone in an air sample with nitric oxide (NO).•The chemiluminescence from the NO-O3 reaction (with excess NO) is p...

  3. Equating Semi-Continuous (SC) PM2.5 Mass Monitor Measurement Values with Federal Reference Method (FRM) PM2.5 Monitor Measurement Values

    EPA Science Inventory

    The effects of fine particulate matter (PM2.5) on human health are well documented (Pope et al., 2002). In order to spatially and temporally assess the impact of PM2.5 on the U.S. population, the U.S. Environmental Protection Agency (U.S. EPA) operates a ne...

  4. Passive sampler for PM10-2.5 aerosol.

    PubMed

    Leith, David; Sommerlatt, Darrell; Boundy, Maryanne G

    2007-03-01

    This study investigates the use of a small passive sampler for aerosol particles to determine particulate matter (PM)10-2.5 concentrations in outdoor air. The passive sampler collects particles by gravity, diffusion, and convective diffusion onto a glass coverslip that is then examined with an optical microscope; digital images are processed with free software and the resultant PM10-2.5 concentrations determined. Both the samplers and the analyses are relatively inexpensive. Passive samplers were collocated with Federal Reference Method (FRM) samplers in Chapel Hill, NC; Phoenix, AZ; and Birmingham, AL; for periods from 5 to 15 days. Particles consisted primarily of inorganic dusts at some sites and a mix of industrial and inorganic materials at other sites. Measured concentrations ranged from < 10 microg/m3 to approximately 40 microg/m3. Overall, PM10-2.5 concentrations measured with the passive samplers were within approximately 1 standard deviation of concentrations measured with the FRM samplers. Concentrations determined with passive samplers depend on assumptions about particle density and shape factors and may also depend somewhat on local wind speed and turbulence; accurate values for these parameters may not be known. The degree of agreement between passive and FRM concentrations measured here suggests that passive measurements may not be overly dependent on accurate knowledge of these parameters.

  5. Using structural equation modeling to construct calibration equations relating PM2.5 mass concentration samplers to the federal reference method sampler

    NASA Astrophysics Data System (ADS)

    Bilonick, Richard A.; Connell, Daniel P.; Talbott, Evelyn O.; Rager, Judith R.; Xue, Tao

    2015-02-01

    The objective of this study was to remove systematic bias among fine particulate matter (PM2.5) mass concentration measurements made by different types of samplers used in the Pittsburgh Aerosol Research and Inhalation Epidemiology Study (PARIES). PARIES is a retrospective epidemiology study that aims to provide a comprehensive analysis of the associations between air quality and human health effects in the Pittsburgh, Pennsylvania, region from 1999 to 2008. Calibration was needed in order to minimize the amount of systematic error in PM2.5 exposure estimation as a result of including data from 97 different PM2.5 samplers at 47 monitoring sites. Ordinary regression often has been used for calibrating air quality measurements from pairs of measurement devices; however, this is only appropriate when one of the two devices (the "independent" variable) is free from random error, which is rarely the case. A group of methods known as "errors-in-variables" (e.g., Deming regression, reduced major axis regression) has been developed to handle calibration between two devices when both are subject to random error, but these methods require information on the relative sizes of the random errors for each device, which typically cannot be obtained from the observed data. When data from more than two devices (or repeats of the same device) are available, the additional information is not used to inform the calibration. A more general approach that often has been overlooked is the use of a measurement error structural equation model (SEM) that allows the simultaneous comparison of three or more devices (or repeats). The theoretical underpinnings of all of these approaches to calibration are described, and the pros and cons of each are discussed. In particular, it is shown that both ordinary regression (when used for calibration) and Deming regression are particular examples of SEMs but with substantial deficiencies. To illustrate the use of SEMs, the 7865 daily average PM2.5 mass concentration measurements made by seven collocated samplers at an urban monitoring site in Pittsburgh, Pennsylvania, were used. These samplers, which included three federal reference method (FRM) samplers, three speciation samplers, and a tapered element oscillating microbalance (TEOM), operated at various times during the 10-year PARIES study period. Because TEOM measurements are known to depend on temperature, the constructed SEM provided calibration equations relating the TEOM to the FRM and speciation samplers as a function of ambient temperature. It was shown that TEOM imprecision and TEOM bias (relative to the FRM) both decreased as temperature increased. It also was shown that the temperature dependency for bias was non-linear and followed a sigmoidal (logistic) pattern. The speciation samplers exhibited only small bias relative to the FRM samplers, although the FRM samplers were shown to be substantially more precise than both the TEOM and the speciation samplers. Comparison of the SEM results to pairwise simple linear regression results showed that the regression results can differ substantially from the correctly-derived calibration equations, especially if the less-precise device is used as the independent variable in the regression.

  6. The Effectors and Sensory Sites of Formaldehyde-responsive Regulator FrmR and Metal-sensing Variant *

    PubMed Central

    Osman, Deenah; Piergentili, Cecilia; Chen, Junjun; Sayer, Lucy N.; Usón, Isabel; Huggins, Thomas G.; Robinson, Nigel J.; Pohl, Ehmke

    2016-01-01

    The DUF156 family of DNA-binding transcriptional regulators includes metal sensors that respond to cobalt and/or nickel (RcnR, InrS) or copper (CsoR) plus CstR, which responds to persulfide, and formaldehyde-responsive FrmR. Unexpectedly, the allosteric mechanism of FrmR from Salmonella enterica serovar Typhimurium is triggered by metals in vitro, and variant FrmRE64H gains responsiveness to Zn(II) and cobalt in vivo. Here we establish that the allosteric mechanism of FrmR is triggered directly by formaldehyde in vitro. Sensitivity to formaldehyde requires a cysteine (Cys35 in FrmR) conserved in all DUF156 proteins. A crystal structure of metal- and formaldehyde-sensing FrmRE64H reveals that an FrmR-specific amino-terminal Pro2 is proximal to Cys35, and these residues form the deduced formaldehyde-sensing site. Evidence is presented that implies that residues spatially close to the conserved cysteine tune the sensitivities of DUF156 proteins above or below critical thresholds for different effectors, generating the semblance of specificity within cells. Relative to FrmR, RcnR is less responsive to formaldehyde in vitro, and RcnR does not sense formaldehyde in vivo, but reciprocal mutations FrmRP2S and RcnRS2P, respectively, impair and enhance formaldehyde reactivity in vitro. Formaldehyde detoxification by FrmA requires S-(hydroxymethyl)glutathione, yet glutathione inhibits formaldehyde detection by FrmR in vivo and in vitro. Quantifying the number of FrmR molecules per cell and modeling formaldehyde modification as a function of [formaldehyde] demonstrates that FrmR reactivity is optimized such that FrmR is modified and frmRA is derepressed at lower [formaldehyde] than required to generate S-(hydroxymethyl)glutathione. Expression of FrmA is thereby coordinated with the accumulation of its substrate. PMID:27474740

  7. User's guide for FRMOD, a zero dimensional FRM burn code

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Driemeryer, D.; Miley, G.H.

    1979-10-15

    The zero-dimensional FRM plasma burn code, FRMOD is written in the FORTRAN language and is currently available on the Control Data Corporation (CDC) 7600 computer at the Magnetic Fusion Energy Computer Center (MFECC), sponsored by the US Department of Energy, in Livermore, CA. This guide assumes that the user is familiar with the system architecture and some of the utility programs available on the MFE-7600 machine, since online documentation is available for system routines through the use of the DOCUMENT utility. Users may therefore refer to it for answers to system related questions.

  8. Generating a Metal-responsive Transcriptional Regulator to Test What Confers Metal Sensing in Cells*

    PubMed Central

    Osman, Deenah; Piergentili, Cecilia; Chen, Junjun; Chakrabarti, Buddhapriya; Foster, Andrew W.; Lurie-Luke, Elena; Huggins, Thomas G.; Robinson, Nigel J.

    2015-01-01

    FrmR from Salmonella enterica serovar typhimurium (a CsoR/RcnR-like transcriptional de-repressor) is shown to repress the frmRA operator-promoter, and repression is alleviated by formaldehyde but not manganese, iron, cobalt, nickel, copper, or Zn(II) within cells. In contrast, repression by a mutant FrmRE64H (which gains an RcnR metal ligand) is alleviated by cobalt and Zn(II). Unexpectedly, FrmR was found to already bind Co(II), Zn(II), and Cu(I), and moreover metals, as well as formaldehyde, trigger an allosteric response that weakens DNA affinity. However, the sensory metal sites of the cells' endogenous metal sensors (RcnR, ZntR, Zur, and CueR) are all tighter than FrmR for their cognate metals. Furthermore, the endogenous metal sensors are shown to out-compete FrmR. The metal-sensing FrmRE64H mutant has tighter metal affinities than FrmR by approximately 1 order of magnitude. Gain of cobalt sensing by FrmRE64H remains enigmatic because the cobalt affinity of FrmRE64H is substantially weaker than that of the endogenous cobalt sensor. Cobalt sensing requires glutathione, which may assist cobalt access, conferring a kinetic advantage. For Zn(II), the metal affinity of FrmRE64H approaches the metal affinities of cognate Zn(II) sensors. Counter-intuitively, the allosteric coupling free energy for Zn(II) is smaller in metal-sensing FrmRE64H compared with nonsensing FrmR. By determining the copies of FrmR and FrmRE64H tetramers per cell, then estimating promoter occupancy as a function of intracellular Zn(II) concentration, we show how a modest tightening of Zn(II) affinity, plus weakened DNA affinity of the apoprotein, conspires to make the relative properties of FrmRE64H (compared with ZntR and Zur) sufficient to sense Zn(II) inside cells. PMID:26109070

  9. The ESA FRM4DOAS project: Towards a quality-controlled MAXDOAS Centralized Processing System

    NASA Astrophysics Data System (ADS)

    Hendrick, Francois; Fayt, Caroline; Friess, Udo; Kreher, Karin; Piters, Ankie; Richter, Andreas; Wagner, Thomas; Cede, Alexander; Spinei, Elena; von Bismarck, Jonas; Fehr, Thorsten; Van Roozendael, Michel

    2017-04-01

    The Fiducial Reference Measurements for Ground-Based DOAS Air-Quality Observations (FRM4DOAS) is a two-year project funded by the European Space Agency (ESA). Started in July 2016, FRM4DOAS aims at further harmonizing MAXDOAS measurements and data sets, through (1) the specification of best practices for instrument operation, (2) the selection of state-of-the art retrieval algorithms, procedures, and settings, (3) the demonstration of a centralised rapid-delivery (6-24h latency) processing system for MAXDOAS instruments to be operated within the international Network for the Detection of Atmospheric Composition Change (NDACC). The project also links with the Pandonia initiative. In a first phase, the system concentrates on the development of 3 key products: NO2 vertical profiles, total O3 and tropospheric HCHO profiles, which will be retrieved at 11 MAXDOAS pilot stations. The system will also be tested and validated on data from the CINDI-2 campaign, and designed to allow further extension after commissioning. These activities will help and guarantee that homogenous, fully traceable, and quality-controlled datasets are generated from reference ground-based UV-vis instruments, which will play a crucial role in the validation of future ESA/Copernicus Sentinel satellite missions S-5P, S-4, and S-5.

  10. Measurements of particulate semi-volatile material

    NASA Astrophysics Data System (ADS)

    Pang, Yanbo

    2000-10-01

    A new innovative sampling system, PC-BOSS, was developed by the combination of particle concentrator and BOSS denuder techniques in response to the new EPA PM2.5 standard and to meet top research priorities for particulate matter that were identified by the National Research Council. The PC-BOSS (P_article C_oncentrator- B_righam Young University O_rganic S_ampling S_ystem) can accurately determine not only PM2.5 stable mass and species such as sulfate, but also particulate semi- volatile material. Several field comparison studies of the PC-BOSS with the EPA PM2.5 reference method and state-of-the-art fine particle measurement methods confirm the capability of the PC-BOSS to accurately determine particulate semi-volatile material, especially organic compounds. This is the first routine sampling system for the determination of both particulate semi-volatile inorganic and organic material. Two other denuder system samplers for the determination of PM2.5 total mass including semi-volatile material were also developed for PM2.5 research and exposure monitoring. Results of studies around the United States indicate that the EPA PM2.5 FRM (Federal Reference Method) under- measured PM2.5 mass by 20-30% compared to PC-BOSS results due to the loss of particulate nitrate and semi-volatile organic compounds during sampling. Organic material is mostly responsible for this under- measurement by the FRM. Using our new sampling system in epidemiological and exposure studies will be essential to providing answers to some top research priorities for particulate matter and promote a better PM2.5 standard for the protection of human health because some fractions of particulate semi-volatile organic compounds are toxic and are possibly responsible for health effects associated with exposure to particulate matter. The atmospheric chemistry of organic aerosols in the troposphere and stratosphere is still largely unknown because of the lack of detailed organic aerosol information. The importance of organic aerosols might also be underestimated because current data on organic aerosols in the troposphere and stratosphere were mostly obtained by traditional methods, like the FRM method. Using PC-BOSS to study organic aerosols in the troposphere and stratosphere will provide not only more but also more accurate information about organic aerosols, and significantly improve the understanding of the role of aerosols in global warming, ozone depletion, and atmospheric heterogenous chemistry.

  11. PM2.5 Monitors in New England | Air Quality Planning Unit ...

    EPA Pesticide Factsheets

    2017-04-10

    The New England states are currently operating a network of 58 ambient PM2.5 air quality monitors that meet EPA's Federal Reference Method (FRM) for PM2.5, which is necessary in order for the resultant data to be used for attainment/non-attainment purposes. These monitors collect particles in the ambient air smaller than 2.5 microns in size on a filter, which is weighed prior and post sampling to produce a 24-hour sample concentration.

  12. Design and evaluation of an inlet conditioner to dry particles for real-time particle sizers.

    PubMed

    Peters, Thomas M; Riss, Adam L; Holm, Ricky L; Singh, Manisha; Vanderpool, Robert W

    2008-04-01

    Real-time particle sizers provide rapid information about atmospheric particles, particularly peak exposures, which may be important in the development of adverse health outcomes. However, these instruments are subject to erroneous readings in high-humidity environments when compared with measurements from filter-based, federal reference method (FRM) samplers. Laboratory tests were conducted to evaluate the ability of three inlet conditioners to dry aerosol prior to entering a real-time particle sizer for measuring coarse aerosols (Model 3321 Aerodynamic Particle Sizer, APS) under simulated highly humid conditions. Two 30 day field studies in Birmingham, AL, USA were conducted to compare the response of two APSs operated with and without an inlet conditioner to that measured with FRM samplers. In field studies, the correlation of PM(10-2.5) derived from the APS and that measured with the FRM was substantially stronger with an inlet conditioner applied (r2 ranged from 0.91 to 0.99) than with no conditioner (r2 = 0.61). Laboratory experiments confirmed the ability of the heater and desiccant conditioner to remove particle-borne moisture. In field tests, water was found associated with particles across the sizing range of the APS (0.5 microm to 20 microm) when relative humidity was high in Birmingham. Certain types of inlet conditioners may substantially improve the correlation between particulate mass concentration derived from real-time particle sizers and filter-based samplers in humid conditions.

  13. Characterisation and optimisation of the new Prompt Gamma-ray Activation Analysis (PGAA) facility at FRM II

    NASA Astrophysics Data System (ADS)

    Canella, Lea; Kudějová, Petra; Schulze, Ralf; Türler, Andreas; Jolie, Jan

    2011-04-01

    At the research reactor Forschungs-Neutronenquelle Heinz Maier-Leibnitz (FRM II) a new Prompt Gamma-ray Activation Analysis (PGAA) facility was installed. The instrument was originally built and operating at the spallation source at the Paul Scherrer Institute in Switzerland. After a careful re-design in 2004-2006, the new PGAA instrument was ready for operation at FRM II. In this paper the main characteristics and the current operation conditions of the facility are described. The neutron flux at the sample position can reach up 6.07×1010 [cm-2 s-1], thus the optimisation of some parameters, e.g. the beam background, was necessary in order to achieve a satisfactory analytical sensitivity for routine measurements. Once the optimal conditions were reached, detection limits and sensitivities for some elements, like for example H, B, C, Si, or Pb, were calculated and compared with other PGAA facilities. A standard reference material was also measured in order to show the reliability of the analysis under different conditions at this instrument.

  14. Regulatory impact analysis and regulatory support document: Control of air pollution; determination of significance for nonroad sources and emission standards for new nonroad compression-ignition engines at or above 37 kilowatts (50 horsepower). Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Trimble, T.; North, D.R.; Green, K.A.H.

    1994-05-27

    The regulatory impact analysis and support document provides additional information in support of the Final Rulemaking (FRM). This FRM will regulate all new nonroad compression-ignition engines greater than or equal to 37 kilowatts (50 hp), except engines which propel or are used on marine vessels, aircraft engines, engines which propel locomotives, and engines regulated by the Mining, Safety, and Health Administration. The regulated engines are hereafter referred to as nonroad large CI engines. The goal of this regulation is to substantially reduce NOx emission and smoke from nonroad large CI engines beginning in the 1996 model year.

  15. Promoting flood risk reduction: The role of insurance in Germany and England

    NASA Astrophysics Data System (ADS)

    Surminski, Swenja; Thieken, Annegret H.

    2017-10-01

    Improving society's ability to prepare for, respond to and recover from flooding requires integrated, anticipatory flood risk management (FRM). However, most countries still focus their efforts on responding to flooding events if and when they occur rather than addressing their current and future vulnerability to flooding. Flood insurance is one mechanism that could promote a more ex ante approach to risk by supporting risk reduction activities. This paper uses an adapted version of Easton's System Theory to investigate the role of insurance for FRM in Germany and England. We introduce an anticipatory FRM framework, which allows flood insurance to be considered as part of a broader policy field. We analyze if and how flood insurance can catalyze a change toward a more anticipatory approach to FRM. In particular we consider insurance's role in influencing five key components of anticipatory FRM: risk knowledge, prevention through better planning, property-level protection measures, structural protection and preparedness (for response). We find that in both countries FRM is still a reactive, event-driven process, while anticipatory FRM remains underdeveloped. Collaboration between insurers and FRM decision-makers has already been successful, for example in improving risk knowledge and awareness, while in other areas insurance acts as a disincentive for more risk reduction action. In both countries there is evidence that insurance can play a significant role in encouraging anticipatory FRM, but this remains underutilized. Effective collaboration between insurers and government should not be seen as a cost, but as an investment to secure future insurability through flood resilience.

  16. HIERARCHIAL BAYESIAN CALIBRATION: AN APPLICATION TO AIRBORNE PARTICULATE MATTER MONITORING DATA

    EPA Science Inventory

    In studies of the relationship between airborne fine particulate matter (PM2.5) and health, researchers frequently use monitoring data with the most extensive temporal coverage. Such data may come from a monitor that is not a federal reference monitor (FRM), a monitor that is d...

  17. Spectral imaging and passive sampling to investigate particle sources in urban desert regions.

    PubMed

    Wagner, Jeff; Casuccio, Gary

    2014-07-01

    Two types of electron microscopy analyses were employed along with geographic information system (GIS) mapping to investigate potential sources of PM2.5 and PM10 (airborne particulate matter smaller than 2.5 and 10 μm, respectively) in two urbanized desert areas known to exhibit PM excursions. Integrated spectral imaging maps were obtained from scanning electron microscopy/energy-dispersive X-ray spectroscopy (SEM/EDS) analyses of 13 filters collected in Imperial Valley, California. Seven were from 24 h PM10 Federal Reference Method (FRM) samplers and six were from PM2.5 FRM samplers. This technique enabled extraction of information from particles collected on complex filter matrices, and indicated that all samples exhibited substantial proportions of crustal particles. Six Imperial PM2.5 and PM10 filters selected from unusually high-PM days exhibited more large particles (2.5-15 and 10-30 μm, respectively) than did filters from low-PM days, and were more consistent with soils analyzed from the region. High winds were present on three of the six high-PM days. One of the high-PM2.5 filters also exhibited substantial fine carbonaceous soot PM, suggesting significant contributions from a combustion source. Computer-controlled SEM/EDS (CCSEM/EDS) was conducted on PM collected with UNC Passive samplers from Phoenix, Arizona. The passive samplers showed good agreement with co-located FRM PM10 and PM2.5 measurements (μg m(-3)), and also enabled detailed individual particle analysis. The CCSEM/EDS data revealed mostly crustal particles in both the Phoenix fine and coarse PM10 fractions. GIS maps of multiple dust-related parameters confirm that both Imperial Valley and Phoenix possess favorable conditions for airborne crustal PM from natural and anthropogenic sources.

  18. Spreading dynamics of forget-remember mechanism

    NASA Astrophysics Data System (ADS)

    Deng, Shengfeng; Li, Wei

    2017-04-01

    We study extensively the forget-remember mechanism (FRM) for message spreading, originally introduced in Eur. Phys. J. B 62, 247 (2008), 10.1140/epjb/e2008-00139-4. The freedom of specifying forget-remember functions governing the FRM can enrich the spreading dynamics to a very large extent. The master equation is derived for describing the FRM dynamics. By applying the mean field techniques, we have shown how the steady states can be reached under certain conditions, which agrees well with the Monte Carlo simulations. The distributions of forget and remember times can be explicitly given when the forget-remember functions take linear or exponential forms, which might shed some light on understanding the temporal nature of diseases like flu. For time-dependent FRM there is an epidemic threshold related to the FRM parameters. We have proven that the mean field critical transmissibility for the SIS model and the critical transmissibility for the SIR model are the lower and the the upper bounds of the critical transmissibility for the FRM model, respectively.

  19. Comparison and evaluation of in situ and filter carbon measurements at the Fresno Supersite

    NASA Astrophysics Data System (ADS)

    Watson, John G.; Chow, Judith C.

    2002-11-01

    The Fresno Supersite in Fresno, California, USA, acquires in situ 5- to 60-min average PM2.5 organic carbon (OC), elemental carbon (EC), and total carbon (TC) measurements by the following methods: (1) thermal evolution carbon analyzer for organic, elemental, and total carbon; (2) single-wavelength and seven-color aethalometer for black carbon (BC); and (3) photoionization for particle-bound polycyclic aromatic hydrocarbons. Twenty-four-hour average PM2.5 filter-based measurements include (1) nondenuded quartz filters with no backup filter in a PM2.5 Federal Reference Method (FRM) sampler; (2) quartz filters behind an organic carbon denuder with a quartz backup filter in a Reference Ambient Aerosol Sampler (RAAS); (3) nondenuded quartz filters with backup filter in a RAAS; and (4) nondenuded quartz filters with no backup filter in a sequential filter sampler. Filter samples are analyzed after sampling by the Interagency Monitoring of Protected Visual Environments (IMPROVE) thermal/optical reflectance carbon analysis protocol. Collocated measurements are examined for year 2000. Measurement equivalence is found for PM2.5 mass, light transmission, and TC between the FRM and RAAS speciation samplers. The average ratios of front filter carbon between the denuded and nondenuded channels in the RAAS sampler are 0.83 ± 0.19 for TC, 0.81 ± 0.20 for OC, and 1.01 ± 0.33 for EC. The average differences for TC and OC are low (1.2 to 1.4 μg m-3) and are comparable to the measurement uncertainties. Continuous thermal evolution carbon measurements are not comparable to filter measurements. Aethalometer BC and filter EC are highly correlated, but filter EC is consistently 20-25% higher than continuous aethalometer BC. Pairwise comparisons show filter EC measurements acquired in this study are predictable from aethalometer BC measurements.

  20. Nonstationary decision model for flood risk decision scaling

    NASA Astrophysics Data System (ADS)

    Spence, Caitlin M.; Brown, Casey M.

    2016-11-01

    Hydroclimatic stationarity is increasingly questioned as a default assumption in flood risk management (FRM), but successor methods are not yet established. Some potential successors depend on estimates of future flood quantiles, but methods for estimating future design storms are subject to high levels of uncertainty. Here we apply a Nonstationary Decision Model (NDM) to flood risk planning within the decision scaling framework. The NDM combines a nonstationary probability distribution of annual peak flow with optimal selection of flood management alternatives using robustness measures. The NDM incorporates structural and nonstructural FRM interventions and valuation of flows supporting ecosystem services to calculate expected cost of a given FRM strategy. A search for the minimum-cost strategy under incrementally varied representative scenarios extending across the plausible range of flood trend and value of the natural flow regime discovers candidate FRM strategies that are evaluated and compared through a decision scaling analysis (DSA). The DSA selects a management strategy that is optimal or close to optimal across the broadest range of scenarios or across the set of scenarios deemed most likely to occur according to estimates of future flood hazard. We illustrate the decision framework using a stylized example flood management decision based on the Iowa City flood management system, which has experienced recent unprecedented high flow episodes. The DSA indicates a preference for combining infrastructural and nonstructural adaptation measures to manage flood risk and makes clear that options-based approaches cannot be assumed to be "no" or "low regret."

  1. Fuzzy regression modeling for tool performance prediction and degradation detection.

    PubMed

    Li, X; Er, M J; Lim, B S; Zhou, J H; Gan, O P; Rutkowski, L

    2010-10-01

    In this paper, the viability of using Fuzzy-Rule-Based Regression Modeling (FRM) algorithm for tool performance and degradation detection is investigated. The FRM is developed based on a multi-layered fuzzy-rule-based hybrid system with Multiple Regression Models (MRM) embedded into a fuzzy logic inference engine that employs Self Organizing Maps (SOM) for clustering. The FRM converts a complex nonlinear problem to a simplified linear format in order to further increase the accuracy in prediction and rate of convergence. The efficacy of the proposed FRM is tested through a case study - namely to predict the remaining useful life of a ball nose milling cutter during a dry machining process of hardened tool steel with a hardness of 52-54 HRc. A comparative study is further made between four predictive models using the same set of experimental data. It is shown that the FRM is superior as compared with conventional MRM, Back Propagation Neural Networks (BPNN) and Radial Basis Function Networks (RBFN) in terms of prediction accuracy and learning speed.

  2. Historical Prediction Modeling Approach for Estimating Long-Term Concentrations of PM2.5 in Cohort Studies before the 1999 Implementation of Widespread Monitoring.

    PubMed

    Kim, Sun-Young; Olives, Casey; Sheppard, Lianne; Sampson, Paul D; Larson, Timothy V; Keller, Joshua P; Kaufman, Joel D

    2017-01-01

    Recent cohort studies have used exposure prediction models to estimate the association between long-term residential concentrations of fine particulate matter (PM2.5) and health. Because these prediction models rely on PM2.5 monitoring data, predictions for times before extensive spatial monitoring present a challenge to understanding long-term exposure effects. The U.S. Environmental Protection Agency (EPA) Federal Reference Method (FRM) network for PM2.5 was established in 1999. We evaluated a novel statistical approach to produce high-quality exposure predictions from 1980 through 2010 in the continental United States for epidemiological applications. We developed spatio-temporal prediction models using geographic predictors and annual average PM2.5 data from 1999 through 2010 from the FRM and the Interagency Monitoring of Protected Visual Environments (IMPROVE) networks. Temporal trends before 1999 were estimated by using a) extrapolation based on PM2.5 data in FRM/IMPROVE, b) PM2.5 sulfate data in the Clean Air Status and Trends Network, and c) visibility data across the Weather Bureau Army Navy network. We validated the models using PM2.5 data collected before 1999 from IMPROVE, California Air Resources Board dichotomous sampler monitoring (CARB dichot), the Children's Health Study (CHS), and the Inhalable Particulate Network (IPN). In our validation using pre-1999 data, the prediction model performed well across three trend estimation approaches when validated using IMPROVE and CHS data (R2 = 0.84-0.91) with lower R2 values in early years. Model performance using CARB dichot and IPN data was worse (R2 = 0.00-0.85) most likely because of fewer monitoring sites and inconsistent sampling methods. Our prediction modeling approach will allow health effects estimation associated with long-term exposures to PM2.5 over extended time periods ≤ 30 years. Citation: Kim SY, Olives C, Sheppard L, Sampson PD, Larson TV, Keller JP, Kaufman JD. 2017. Historical prediction modeling approach for estimating long-term concentrations of PM2.5 in cohort studies before the 1999 implementation of widespread monitoring. Environ Health Perspect 125:38-46; http://dx.doi.org/10.1289/EHP131.

  3. Historical Prediction Modeling Approach for Estimating Long-Term Concentrations of PM2.5 in Cohort Studies before the 1999 Implementation of Widespread Monitoring

    PubMed Central

    Kim, Sun-Young; Olives, Casey; Sheppard, Lianne; Sampson, Paul D.; Larson, Timothy V.; Keller, Joshua P.; Kaufman, Joel D.

    2016-01-01

    Introduction: Recent cohort studies have used exposure prediction models to estimate the association between long-term residential concentrations of fine particulate matter (PM2.5) and health. Because these prediction models rely on PM2.5 monitoring data, predictions for times before extensive spatial monitoring present a challenge to understanding long-term exposure effects. The U.S. Environmental Protection Agency (EPA) Federal Reference Method (FRM) network for PM2.5 was established in 1999. Objectives: We evaluated a novel statistical approach to produce high-quality exposure predictions from 1980 through 2010 in the continental United States for epidemiological applications. Methods: We developed spatio-temporal prediction models using geographic predictors and annual average PM2.5 data from 1999 through 2010 from the FRM and the Interagency Monitoring of Protected Visual Environments (IMPROVE) networks. Temporal trends before 1999 were estimated by using a) extrapolation based on PM2.5 data in FRM/IMPROVE, b) PM2.5 sulfate data in the Clean Air Status and Trends Network, and c) visibility data across the Weather Bureau Army Navy network. We validated the models using PM2.5 data collected before 1999 from IMPROVE, California Air Resources Board dichotomous sampler monitoring (CARB dichot), the Children’s Health Study (CHS), and the Inhalable Particulate Network (IPN). Results: In our validation using pre-1999 data, the prediction model performed well across three trend estimation approaches when validated using IMPROVE and CHS data (R2 = 0.84–0.91) with lower R2 values in early years. Model performance using CARB dichot and IPN data was worse (R2 = 0.00–0.85) most likely because of fewer monitoring sites and inconsistent sampling methods. Conclusions: Our prediction modeling approach will allow health effects estimation associated with long-term exposures to PM2.5 over extended time periods ≤ 30 years. Citation: Kim SY, Olives C, Sheppard L, Sampson PD, Larson TV, Keller JP, Kaufman JD. 2017. Historical prediction modeling approach for estimating long-term concentrations of PM2.5 in cohort studies before the 1999 implementation of widespread monitoring. Environ Health Perspect 125:38–46; http://dx.doi.org/10.1289/EHP131 PMID:27340825

  4. Simulation of loss mechanisms in organic solar cells: A description of the mesoscopic Monte Carlo technique and an evaluation of the first reaction method.

    PubMed

    Groves, Chris; Kimber, Robin G E; Walker, Alison B

    2010-10-14

    In this letter we evaluate the accuracy of the first reaction method (FRM) as commonly used to reduce the computational complexity of mesoscale Monte Carlo simulations of geminate recombination and the performance of organic photovoltaic devices. A wide range of carrier mobilities, degrees of energetic disorder, and applied electric field are considered. For the ranges of energetic disorder relevant for most polyfluorene, polythiophene, and alkoxy poly(phenylene vinylene) materials used in organic photovoltaics, the geminate separation efficiency predicted by the FRM agrees with the exact model to better than 2%. We additionally comment on the effects of equilibration on low-field geminate separation efficiency, and in doing so emphasize the importance of the energy at which geminate carriers are created upon their subsequent behavior.

  5. HEASD PM RESEARCH METHODS: PARTICLE METHODS EVALUATION AND DEVELOPMENT

    EPA Science Inventory

    The FRM developed by NERL forms the backbone of the EPA's national monitoring strategy. It is the measurement that defines attainment of the new standard. However, the agency has numerous other needs in assessing the physical and chemical characteristics of ambient fine particl...

  6. Assessment of treatment efficacy and sebosuppressive effect of fractional radiofrequency microneedle on acne vulgaris.

    PubMed

    Lee, Kyung Real; Lee, Eo Gin; Lee, Hee Jung; Yoon, Moon Soo

    2013-12-01

    A minimally invasive fractional radiofrequency microneedle (FRM) device has been used in skin rejuvenation and acne scars, and a recent pilot study demonstrated the positive therapeutic effect on acne. We evaluated the efficacy of FRM device for acne vulgaris in Asians and conducted objective measurement to assess its effect on sebum production. Twenty Korean patients with acne vulgaris received a single full-face FRM treatment. Outcome assessments included standardized photography, physician's global assessment, patient's satisfaction scores, acne lesion count, and objective measurements of casual sebum level (CSL) and sebum excretion rate (SER). They were evaluated at baseline and 2, 4, 8 weeks after the treatment. After a single FRM treatment, the CSL and the SER showed 30-60% and 70-80% reduction, respectively, at week 2 (P < 0.01), and remained below the baseline level until week 8. Physician's global improvement scores for acne severity and acne lesion count also revealed clinical improvement with maximum efficacy at week 2, but returned to the baseline in most patients by week 8. Patients' satisfaction scores (0-4) were above 2 on average, and adverse effects were minimal. This prospective study demonstrated the sebosuppressive effect from a single FRM treatment, but its therapeutic efficacy in acne requires further evaluation. © 2013 Wiley Periodicals, Inc.

  7. Study of fusion product effects in field-reversed mirrors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Driemeyer, D.E.

    1980-01-01

    The effect of fusion products (fps) on Field-Reversed Mirror (FRM) reactor concepts has been evaluated through the development of two new computer models. The first code (MCFRM) treats fps as test particles in a fixed background plasma, which is represented as a fluid. MCFRM includes a Monte Carlo treatment of Coulomb scattering and thus provides an accurate treatment of fp behavior even at lower energies where pitch-angle scattering becomes important. The second code (FRMOD) is a steady-state, globally averaged, two-fluid (ion and electron), point model of the FRM plasma that incorporates fp heating and ash buildup values which are consistentmore » with the MCFRM calculations. These codes have been used extensively in the development of an advanced-fuel FRM reactor design (SAFFIRE). A Catalyzed-D version of the plant is also discussed along with an investigation of the steady-state energy distribution of fps in the FRM. User guides for the two computer codes are also included.« less

  8. The C. elegans VIG-1 and FRM-1 modulate carbachol-stimulated ERK1/2 activation in chinese hamster ovary cells expressing the muscarinic acetylcholine receptor GAR-3.

    PubMed

    Shin, Youngmi; Cho, Nam Jeong

    2014-04-01

    Many neurotransmitter receptors are known to interact with a variety of intracellular proteins that modulate signaling processes. In an effort to understand the molecular mechanism by which acetylcholine (ACh) signaling is modulated, we searched for proteins that interact with GAR-3, the Caenorhabditis elegans homolog of muscarinic ACh receptors. We isolated two proteins, VIG-1 and FRM-1, in a yeast two-hybrid screen of a C. elegans cDNA library using the third intracellular (i3) loop of GAR-3 as bait. To test whether these proteins regulate ACh signaling, we utilized Chinese hamster ovary (CHO) cells stably expressing GAR-3 (GAR-3/CHO cells). Previously we have shown that the cholinergic agonist carbachol stimulates extracellular signal-regulated kinases 1 and 2 (ERK1/2) activation in an atropine-sensitive manner in this cell line. When VIG-1 was transiently expressed in GAR-3/CHO cells, carbachol-stimulated ERK1/2 activation was substantially reduced. In contrast, transient expression of FRM-1 significantly enhanced carbachol-stimulated ERK1/2 activation. Neither VIG-1 nor FRM-1 expression appeared to alter the affinity between GAR-3 and carbachol. In support of this notion, expression of these proteins did not affect GAR-3-mediated phospholipase C activation. To verify the modulation of ERK1/2 activity by VIG-1 and FRM-1, we used an i3 loop deletion mutant of GAR-3 (termed GAR-3Δi3). Carbachol treatment evoked robust ERK1/2 activation in CHO cells stably expressing the deletion mutant (GAR-3Δi3/CHO cells). However, transient expression of either VIG-1 or FRM-1 had little effect on carbachol-stimulated ERK1/2 activation in GAR-3Δi3/CHO cells. Taken together, these results indicate that VIG-1 and FRM-1 regulate GAR-3-mediated ERK1/2 activation by interacting with the i3 loop of GAR-3.

  9. Particle-Sizing System for Scanning Electron Microscope Images of Solid- Propellant Combustion Exhaust

    DTIC Science & Technology

    1991-03-01

    bl2[3]; 1* ditto */ char b13(61, b1413]; /* unused at the moment ~ char bl5(3], b16 (3], b17[31, b18[3]; /* YIN input buffers * char bl9[3], b20[3...gbool(SET,frm,13,wn.10, 1, ’ALL: Enable HELP screens (Y,N] fatrib,’ - ,&HELPLVL,bl5,NSTR,NSTR); bool2YN(DOSEQ, b16 ); wngbool(SET,frm,14,wn,ll, l,’SEMEX...CLIP, TAG and SIZE without asking[Y.N): fatrib,’ ’ ,&DOSEQ, bl6 ,NSTR.NSTR): bool2YN(DFINVERT,b17); wngbool(SET,frm,15,wn,12, 1, ACQUIRE: Complement

  10. Supporting the information domains of fall-risk management in home care via health information technology.

    PubMed

    Alhuwail, Dari; Koru, Güneş; Mills, Mary Etta

    2016-01-01

    In the United States, home care clinicians often start the episode of care devoid of relevant fall-risk information. By collecting and analyzing qualitative data from 30 clinicians in one home health agency, this case study aimed to understand how the currently adopted information technology solutions supported the clinicians' fall-risk management (FRM) information domains, and explored opportunities to adopt other solutions to better support FRM. The currently adopted electronic health record system and fall-reporting application served only some information domains with a limited capacity. Substantial improvement in addressing the FRM information domains is possible by effectively modifying the existing solutions and purposefully adopting new solutions.

  11. Study of Research and Development Processes through Fuzzy Super FRM Model and Optimization Solutions

    PubMed Central

    Sârbu, Flavius Aurelian; Moga, Monika; Calefariu, Gavrilă; Boșcoianu, Mircea

    2015-01-01

    The aim of this study is to measure resources for R&D (research and development) at the regional level in Romania and also obtain primary data that will be important in making the right decisions to increase competitiveness and development based on an economic knowledge. As our motivation, we would like to emphasize that by the use of Super Fuzzy FRM model we want to determine the state of R&D processes at regional level using a mean different from the statistical survey, while by the two optimization methods we mean to provide optimization solutions for the R&D actions of the enterprises. Therefore to fulfill the above mentioned aim in this application-oriented paper we decided to use a questionnaire and for the interpretation of the results the Super Fuzzy FRM model, representing the main novelty of our paper, as this theory provides a formalism based on matrix calculus, which allows processing of large volumes of information and also delivers results difficult or impossible to see, through statistical processing. Furthermore another novelty of the paper represents the optimization solutions submitted in this work, given for the situation when the sales price is variable, and the quantity sold is constant in time and for the reverse situation. PMID:25821846

  12. The biological function of consciousness

    PubMed Central

    Earl, Brian

    2014-01-01

    This research is an investigation of whether consciousness—one's ongoing experience—influences one's behavior and, if so, how. Analysis of the components, structure, properties, and temporal sequences of consciousness has established that, (1) contrary to one's intuitive understanding, consciousness does not have an active, executive role in determining behavior; (2) consciousness does have a biological function; and (3) consciousness is solely information in various forms. Consciousness is associated with a flexible response mechanism (FRM) for decision-making, planning, and generally responding in nonautomatic ways. The FRM generates responses by manipulating information and, to function effectively, its data input must be restricted to task-relevant information. The properties of consciousness correspond to the various input requirements of the FRM; and when important information is missing from consciousness, functions of the FRM are adversely affected; both of which indicate that consciousness is the input data to the FRM. Qualitative and quantitative information (shape, size, location, etc.) are incorporated into the input data by a qualia array of colors, sounds, and so on, which makes the input conscious. This view of the biological function of consciousness provides an explanation why we have experiences; why we have emotional and other feelings, and why their loss is associated with poor decision-making; why blindsight patients do not spontaneously initiate responses to events in their blind field; why counter-habitual actions are only possible when the intended action is in mind; and the reason for inattentional blindness. PMID:25140159

  13. Behavior of fiber reinforced mortar joints in masonry walls subjected to in-plane shear and out-of-plane bending

    NASA Astrophysics Data System (ADS)

    Armwood, Catherine K.

    In this project, 26 fiber-reinforced mortar (FRM) mixtures are evaluated for their workability and strength characteristics. The specimens tested include two control mixtures and 24 FRMs. The mixtures were made of two types of binders; Type N Portland cement lime (Type N-PCL) and Natural Hydrated Lime 5 (NHL5); and 6 fiber types (5 synthetic fibers and one organic). When tested in flexure, the results indicate that majority of the synthetic fiber mixtures enhanced the performance of the mortar and the nano-nylon and horse hair fibers were the least effective in improving the mortar's modulus of rupture, ductility, and energy absorption. Four FRMs that improved the mortar's mechanical properties most during the flexural strength test were then used to conduct additional experiments. The FRM's compressive strength, as well as flexural and shear bond strength with clay and concrete masonry units were determined. Those four mixtures included Type N-PCL as the binder and 4 synthetic fibers. They were evaluated at a standard laboratory flow rate of 110% +/- 5% and a practical field flow rate of 130% +/- 5%. Results indicate that the use of fibers decreases the compressive strength of the mortar most of the time. However, the bond strength test results were promising: 81% of the FRM mixtures increased the flexural bond strength of the prism. The mixtures at 110 +/- 5% flow rate bonded better with concrete bricks and those ate 130+/-5% flow rate bonded better with clay bricks. The results of the shear bond strength show 50% of the FRM mixtures improved the shear bond strength. The FRM mixtures at 110+/-5% flow rate bonded with clay units provided the most improvement in shear bond strength compared to control specimen results. Along with detailed discussions and derived conclusions of these experiments, this dissertation includes recommendations for the most feasible FRM for different applications.

  14. Cooking Matters for Adults Improves Food Resource Management Skills and Self-confidence Among Low-Income Participants.

    PubMed

    Pooler, Jennifer A; Morgan, Ruth E; Wong, Karen; Wilkin, Margaret K; Blitstein, Jonathan L

    Determine the impact of Cooking Matters for Adults (CM) on food resource management (FRM) skills and self-confidence 6 months after course completion. Quasi-experimental design with nonequivalent comparison group and 6-month follow-up. Cooking Matters for Adults programs in CA, CO, ME, MA, MI, and OR. Participants in CM attending classes in April to July, 2016 (n = 332); comparison group (n = 336). Cooking Matters for Adults educated low-income adults to shop for and prepare healthy meals economically using hands-on meal preparation, facilitated discussion, and an interactive grocery store tour. Classes met for 2 hours, once a week for 6 weeks. Food resource management practices; FRM self-confidence (ie, in shopping for and preparing healthy foods on a budget); worrying that food might run out. Pearson's chi-square test and t tests identified measures associated with outcomes of interest and between-group differences. Repeated-measures linear mixed models with fixed and random effects were used to examine differences in outcomes between participants in CM and nonequivalent comparison group and to estimate the treatment effect of the program at 3 and 6 months after course completion. Six months after course completion, CM participants demonstrated improvements in all outcome measures of interest: Use of FRM practices improved (P = .002) as did FRM confidence (P < .001). Participants also worried less that food would run out before they had money to buy more (P = .03). This study demonstrated a positive impact of including FRM skills and confidence building in a nutrition education program, the effects of which could be seen for 6 months after participation in the program. Equipping low-income families with FRM skills allowed them to access healthier foods even during times of hardship. Copyright © 2017 Society for Nutrition Education and Behavior. All rights reserved.

  15. MEASUREMENT OF FINE PARTICULATE MATTER (NONVOLATILE AND SEMIVOLATILE FRACTIONS) IN FRESNO, CA

    EPA Science Inventory

    Semi-volatile material, including ammonium nitrate and semi-volatile organic material, is often not measured by traditionally used sampling methods including the FRM and the R&P TEOM Monitor. An intensive sampling campaign was performed at the EPA Fresno, CA Supersite during D...

  16. Field evaluations of newly available "interference-free" monitors for nitrogen dioxide and ozone at near-road and conventional National Ambient Air Quality Standards compliance sites.

    PubMed

    Leston, Alan R; Ollison, Will M

    2017-11-01

    Long-standing measurement techniques for determining ground-level ozone (O 3 ) and nitrogen dioxide (NO 2 ) are known to be biased by interfering compounds that result in overestimates of high O 3 and NO 2 ambient concentrations under conducive conditions. An increasing near-ground O 3 gradient (NGOG) with increasing height above ground level is also known to exist. Both the interference bias and NGOG were investigated by comparing data from a conventional Federal Equivalent Method (FEM) O 3 photometer and an identical monitor upgraded with an "interference-free" nitric oxide O 3 scrubber that alternatively sampled at 2 m and 6.2 m inlet heights above ground level (AGL). Intercomparison was also made between a conventional nitrogen oxide (NO x ) chemiluminescence Federal Reference Method (FRM) monitor and a new "direct-measure" NO 2 NO x 405 nm photometer at a near-road air quality measurement site. Results indicate that the O 3 monitor with the upgraded scrubber recorded lower regulatory-oriented concentrations than the deployed conventional metal oxide-scrubbed monitor and that O 3 concentrations 6.2 m AGL were higher than concentrations 2.0 m AGL, the nominal nose height of outdoor populations. Also, a new direct-measure NO 2 photometer recorded generally lower NO 2 regulatory-oriented concentrations than the conventional FRM chemiluminescence monitor, reporting lower daily maximum hourly average concentrations than the conventional monitor about 3 of every 5 days. Employing bias-prone instruments for measurement of ambient ozone or nitrogen dioxide from inlets at inappropriate heights above ground level may result in collection of positively biased data. This paper discusses tests of new regulatory instruments, recent developments in bias-free ozone and nitrogen dioxide measurement technology, and the presence/extent of a near-ground O 3 gradient (NGOG). Collection of unbiased monitor inlet height-appropriate data is crucial for determining accurate design values and meeting National Ambient Air Quality Standards.

  17. LABORATORY AND FIELD EVALUATION OF CRYSTALLIZED DOW 704 OIL ON THE PERFORMANCE OF THE PM2.5 WINS FRACTIONATOR

    EPA Science Inventory

    Subsequent to the PM2.5 FRM's 1997 promulgation, technicians at the CT Dept. of Env. Protection observed that the DOW 704 diffusion oil used in the method's WINS fractionator would occasionally crystallize during field use - particularly under wintertime conditions. While the f...

  18. On the formation modes in vortex interaction for multiple co-axial co-rotating vortex rings

    NASA Astrophysics Data System (ADS)

    Qin, Suyang; Liu, Hong; Xiang, Yang

    2018-01-01

    Interaction among multiple vortices is of particular importance to biological locomotion. It plays an essential role in the force and energy capture. This study examines the motion and dynamics of multiple co-axial co-rotating vortex rings. The vortex rings, which have the same formation time, are successively generated in a piston-cylinder apparatus by accurately controlling the interval time. The flow fields are visualized by the finite-time Lyapunov exponent and then repelling Lagrangian coherent structures (r-LCSs) are determined. Two types of vortex interactions ("strong" and "weak") are defined by investigating the r-LCSs: a strong interaction is indicated by connected r-LCSs showing a channel for fluid transport (termed as a "flux window"); a weak interaction is indicated by disconnected r-LCSs between the vortex rings. For strong interaction, leapfrogging and merger of vortex rings can happen in the later stage of the evolution process; however, the rings are separated for weak interaction. Two distinct formation modes, the formation enhancement mode (FEM) and formation restraint mode (FRM), refer to the effect of one or multiple vortex ring(s) on the initial circulation of the subsequently formed vortex ring. In the FEM, the circulation of a vortex ring is larger than that of an isolated (without interaction) vortex ring. On the other hand, the situation is opposite in the FRM. A dimensionless number reflecting the interaction mechanism, "structure stretching number" S*, is proposed, which evaluates the induced effect of the wake vortices on the formation of a vortex ring. A limiting S* (SL*=(2 ±0.4 ) ×1 0-4) is the bifurcation point of the two formation modes. The augmentation of circulation reaches up to 10% for the FEM when S*SL*), the circulation decreases for at most 20%. The newly defined formation modes and number could shed light on the understanding of the dynamics of multiple vortex ring flows.

  19. Going beyond the flood insurance rate map: insights from flood hazard map co-production

    NASA Astrophysics Data System (ADS)

    Luke, Adam; Sanders, Brett F.; Goodrich, Kristen A.; Feldman, David L.; Boudreau, Danielle; Eguiarte, Ana; Serrano, Kimberly; Reyes, Abigail; Schubert, Jochen E.; AghaKouchak, Amir; Basolo, Victoria; Matthew, Richard A.

    2018-04-01

    Flood hazard mapping in the United States (US) is deeply tied to the National Flood Insurance Program (NFIP). Consequently, publicly available flood maps provide essential information for insurance purposes, but they do not necessarily provide relevant information for non-insurance aspects of flood risk management (FRM) such as public education and emergency planning. Recent calls for flood hazard maps that support a wider variety of FRM tasks highlight the need to deepen our understanding about the factors that make flood maps useful and understandable for local end users. In this study, social scientists and engineers explore opportunities for improving the utility and relevance of flood hazard maps through the co-production of maps responsive to end users' FRM needs. Specifically, two-dimensional flood modeling produced a set of baseline hazard maps for stakeholders of the Tijuana River valley, US, and Los Laureles Canyon in Tijuana, Mexico. Focus groups with natural resource managers, city planners, emergency managers, academia, non-profit, and community leaders refined the baseline hazard maps by triggering additional modeling scenarios and map revisions. Several important end user preferences emerged, such as (1) legends that frame flood intensity both qualitatively and quantitatively, and (2) flood scenario descriptions that report flood magnitude in terms of rainfall, streamflow, and its relation to an historic event. Regarding desired hazard map content, end users' requests revealed general consistency with mapping needs reported in European studies and guidelines published in Australia. However, requested map content that is not commonly produced included (1) standing water depths following the flood, (2) the erosive potential of flowing water, and (3) pluvial flood hazards, or flooding caused directly by rainfall. We conclude that the relevance and utility of commonly produced flood hazard maps can be most improved by illustrating pluvial flood hazards and by using concrete reference points to describe flooding scenarios rather than exceedance probabilities or frequencies.

  20. Benefits and Limitations of Real Options Analysis for the Practice of River Flood Risk Management

    NASA Astrophysics Data System (ADS)

    Kind, Jarl M.; Baayen, Jorn H.; Botzen, W. J. Wouter

    2018-04-01

    Decisions on long-lived flood risk management (FRM) investments are complex because the future is uncertain. Flexibility and robustness can be used to deal with future uncertainty. Real options analysis (ROA) provides a welfare-economics framework to design and evaluate robust and flexible FRM strategies under risk or uncertainty. Although its potential benefits are large, ROA is hardly used in todays' FRM practice. In this paper, we investigate benefits and limitations of a ROA, by applying it to a realistic FRM case study for an entire river branch. We illustrate how ROA identifies optimal short-term investments and values future options. We develop robust dike investment strategies and value the flexibility offered by additional room for the river measures. We benchmark the results of ROA against those of a standard cost-benefit analysis and show ROA's potential policy implications. The ROA for a realistic case requires a high level of geographical detail, a large ensemble of scenarios, and the inclusion of stakeholders' preferences. We found several limitations of applying the ROA. It is complex. In particular, relevant sources of uncertainty need to be recognized, quantified, integrated, and discretized in scenarios, requiring subjective choices and expert judgment. Decision trees have to be generated and stakeholders' preferences have to be translated into decision rules. On basis of this study, we give general recommendations to use high discharge scenarios for the design of measures with high fixed costs and few alternatives. Lower scenarios may be used when alternatives offer future flexibility.

  1. Rotatable multifunctional load frames for neutron diffractometers at FRM II—design, specifications and applications

    NASA Astrophysics Data System (ADS)

    Hoelzel, M.; Gan, W. M.; Hofmann, M.; Randau, C.; Seidl, G.; Jüttner, Ph.; Schmahl, W. W.

    2013-05-01

    Novel tensile rigs have been designed and manufactured at the research reactor Heinz Maier-Leibnitz (FRM II, Garching near Munich). Besides tensile and compressive stress, also torsion can be applied. The unique Eulerian cradle type design (ω, χ, and φ axis) allows orienting the stress axis with respect to the scattering vector. Applications of these tensile rigs at our neutron diffractometers enable various investigations of structural changes under mechanical load, e.g. crystallographic texture evolution, stress-induced phase transformations or lattice expansion, and the anisotropy of mechanical response.

  2. Development of an environmental chamber for evaluating the performance of low-cost air quality sensors under controlled conditions

    NASA Astrophysics Data System (ADS)

    Papapostolou, Vasileios; Zhang, Hang; Feenstra, Brandon J.; Polidori, Andrea

    2017-12-01

    A state-of-the-art integrated chamber system has been developed for evaluating the performance of low-cost air quality sensors. The system contains two professional grade chamber enclosures. A 1.3 m3 stainless-steel outer chamber and a 0.11 m3 Teflon-coated stainless-steel inner chamber are used to create controlled aerosol and gaseous atmospheres, respectively. Both chambers are temperature and relative humidity controlled with capability to generate a wide range of environmental conditions. The system is equipped with an integrated zero-air system, an ozone and two aerosol generation systems, a dynamic dilution calibrator, certified gas cylinders, an array of Federal Reference Method (FRM), Federal Equivalent Method (FEM), and Best Available Technology (BAT) reference instruments and an automated control and sequencing software. Our experiments have demonstrated that the chamber system is capable of generating stable and reproducible aerosol and gas concentrations at low, medium, and high levels. This paper discusses the development of the chamber system along with the methods used to quantitatively evaluate sensor performance. Considering that a significant number of academic and research institutions, government agencies, public and private institutions, and individuals are becoming interested in developing and using low-cost air quality sensors, it is important to standardize the procedures used to evaluate their performance. The information discussed herein provides a roadmap for entities who are interested in characterizing air quality sensors in a rigorous, systematic and reproducible manner.

  3. Early administration of tolvaptan preserves renal function in elderly patients with acute decompensated heart failure.

    PubMed

    Kimura, Kazuhiro; Momose, Tomoyasu; Hasegawa, Tomoya; Morita, Takehiro; Misawa, Takuo; Motoki, Hirohiko; Izawa, Atsushi; Ikeda, Uichi

    2016-05-01

    Loop diuretics used in the treatment of heart failure often induce renal impairment. This study was conducted in order to evaluate the renal protective effect of adding tolvaptan (TLV), compared to increasing the furosemide (FRM) dose, for the treatment of acute decompensated heart failure (ADHF) in a real-world elderly patient population. This randomized controlled trial enrolled 52 consecutive hospitalized patients (age 83.4±9.6 years) with ADHF. The patients were assigned alternately to either the TLV group (TLV plus conventional treatment, n=26) or the FRM group (increasing the dose of FRM, n=26). TLV was administered within 24h from admission. The incidence of worsening renal function (WRF) within 7 days from admission was significantly lower in the TLV group (26.9% vs. 57.7%, p=0.025). Furthermore, the rates of occurrence of persistent and late-onset (≥5 days from admission) WRF were significantly lower in the TLV group. Persistent and late-onset WRF were significantly associated with a higher incidence of cardiac death or readmission for worsening heart failure in the 90 days following discharge, compared to transient and early-onset WRF, respectively. Early administration of TLV, compared to increased FRM dosage, reduces the incidence of WRF in real-world elderly ADHF patients. In addition, it reduces the occurrence of 'worse' WRF-persistent and late-onset WRF-which are associated with increased rates of cardiac death or readmission for worsening heart failure in the 90 days after discharge. Copyright © 2015 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  4. The clinical utility of fibrin-related biomarkers in sepsis.

    PubMed

    Toh, Julien M H; Ken-Dror, Gie; Downey, Colin; Abrams, Simon T

    2013-12-01

    Sepsis is associated with systemic inflammatory responses and induction of intravascular fibrin formation. Our aim is to investigate whether three fibrin-related markers (FRM) reflect the extent of coagulation activation in vivo and evaluate their clinical usefulness in identifying as well as monitoring patients with sepsis. Fibrin-degradation products (FDP), D-dimer and soluble fibrin monomer assays were measured on plasma samples from patients in the ICU with sepsis (n = 37), systemic inflammatory response syndrome (SIRS) (n = 35) and healthy individuals (n = 15). The levels were correlated with each other and also with fibrinogen, prothrombin time, platelets and antithrombin III. Clinical correlation was also performed for the diagnosis of sepsis and longitudinal monitoring for survival or death.There was strong correlation between the three FRM (r = 0.38-0.93, P < 0.0001) with only fibrin monomer correlating significantly with prothrombin time, fibrinogen and platelet levels. Clinically, all three FRM could discriminate between patients with sepsis, SIRS and healthy individuals with FDP, and D-dimer showing statistical significance (P < 0.05). No FRM predicted outcome from a single measurement but FDP was significantly able to predict patient survival from serial samples [mean FDP (μg/ml) from 35.36 to 21.37 (first to third ICU-day), P < 0.05]. Fibrin monomer appears the most sensitive indicator of coagulation activation, whereas D-dimer and FDP levels can significantly differentiate ICU patients with sepsis from those without. In addition, FDP would be preferable for monitoring with its statistically significant time-dependent prediction of survival or death from sepsis.

  5. Healthy Choices for Every Body Adult Curriculum Improves Participants' Food Resource Management Skills and Food Safety Practices.

    PubMed

    Adedokun, Omolola A; Plonski, Paula; Jenkins-Howard, Brooke; Cotterill, Debra B; Vail, Ann

    2018-06-01

    To evaluate the impact of the University of Kentucky's Healthy Choices for Every Body (HCEB) adult nutrition education curriculum on participants' food resource management (FRM) skills and food safety practices. A quasi-experimental design was employed using propensity score matching to pair 8 intervention counties with 8 comparison counties. Independent-samples t tests and ANCOVA models compared gains in FRM skills and food safety practices between the intervention and comparison groups (n = 413 and 113, respectively). Propensity score matching analysis showed a statistical balance and similarities between the comparison and intervention groups. Food resource management and food safety gain scores were statistically significantly higher for the intervention group (P < .001), with large effect sizes (d = 0.9) for both variables. The group differences persisted even after controlling for race and age in the ANCOVA models. The HCEB curriculum was effective in improving the FRM skills and food safety practices of participants. Copyright © 2018 Society for Nutrition Education and Behavior. Published by Elsevier Inc. All rights reserved.

  6. Design of multiplier-less sharp transition width non-uniform filter banks using gravitational search algorithm

    NASA Astrophysics Data System (ADS)

    Bindiya T., S.; Elias, Elizabeth

    2015-01-01

    In this paper, multiplier-less near-perfect reconstruction tree-structured filter banks are proposed. Filters with sharp transition width are preferred in filter banks in order to reduce the aliasing between adjacent channels. When sharp transition width filters are designed as conventional finite impulse response filters, the order of the filters will become very high leading to increased complexity. The frequency response masking (FRM) method is known to result in linear-phase sharp transition width filters with low complexity. It is found that the proposed design method, which is based on FRM, gives better results compared to the earlier reported results, in terms of the number of multipliers when sharp transition width filter banks are needed. To further reduce the complexity and power consumption, the tree-structured filter bank is made totally multiplier-less by converting the continuous filter bank coefficients to finite precision coefficients in the signed power of two space. This may lead to performance degradation and calls for the use of a suitable optimisation technique. In this paper, gravitational search algorithm is proposed to be used in the design of the multiplier-less tree-structured uniform as well as non-uniform filter banks. This design method results in uniform and non-uniform filter banks which are simple, alias-free, linear phase and multiplier-less and have sharp transition width.

  7. The new materials science diffractometer STRESS-SPEC at FRM-II

    NASA Astrophysics Data System (ADS)

    Hofmann, M.; Schneider, R.; Seidl, G. A.; Rebelo-Kornmeier, J.; Wimpory, R. C.; Garbe, U.; Brokmeier, H.-G.

    2006-11-01

    In response to the development of new materials and the application of materials and components in new technologies the direct measurement, calculation and evaluation of textures and residual stresses has gained worldwide significance in recent years. In order to cater for the development of these analytical techniques the Materials Science Diffractometer STRESS-SPEC at FRM-II is designed to be equally applied to texture or residual stress analysis by virtue of its flexible configuration and the high neutron flux at the sample position. The instrument is now available for routine operation and here we present details of first experiments and instrument performance.

  8. The Effect of Long-Term Therapeutics, Prophylaxis and Screening Techniques on Aircrew Medical Standards.

    DTIC Science & Technology

    1981-03-01

    percentage of fat , maximal aerobic power, serum concentrations of triglycerides, total cholesterol and HDL cholesterol. This information is obtained fr-m each...drinkinq and physical activity related to health parameters su-h as wei ,iht , body fat content, maximal aerobic T1ewer and serum concentrations of...subjects, and the body fat is estimated from the body density (4). 3. The maximal aerobic power is assessed indirectly according to the method of Astrand

  9. National Dam Safety Program. Lake Como Dam (DE 00028), Delaware River Basin, Mill Creek, Kent County, Delaware. Phase I Inspection Report.

    DTIC Science & Technology

    1980-11-01

    STATEMENT (of the abstract antarod in Block 20, It different frm Report) III. SUPPLEMENTARY NOTES Copies are obtainable from National Technical...should employ a professional engineer experienced in operation and maintanance of darns to develop written operating procedures and a periodic...100 YEAR FLOOD WOULD CAUSE A DAM TO bE OVERTOPPED THEREFORE THE OWNER SHOULD ENGAGE A QUALIFIED PkOFEbSIONAL CONSULTANT USING MORE PERCISE METHODS

  10. Study of the surface contamination of copper with the improved positron annihilation-induced Auger electron spectrometer at NEPOMUC

    NASA Astrophysics Data System (ADS)

    Mayer, J.; Hugenschmidt, C.; Schreckenbach, K.

    2008-10-01

    The high intensity positron source NEPOMUC at the FRM-II in Munich enables measurement times for positron annihilation-induced Auger electron spectroscopy (PAES) of only 2.4 h/spectrum, in contrast to usual lab beams with measurement times up to several days. The high electron background due to surrounding experiments in the experimental hall of the FRM-II has been eliminated and hence background free experiments have become possible. Due to this, the signal to noise ratio has been enhanced to 4.5:1, compared to 1:3 with EAES. In addition, a long-term measurement has been performed in order to observe the contamination of a polycrystalline copper foil at 150 °C.

  11. Sea Temperature Fiducial Reference Measurements for the Validation and Data Gap Bridging of Satellite SST Data Products

    NASA Astrophysics Data System (ADS)

    Wimmer, Werenfrid

    2016-08-01

    The Infrared Sea surface temperature Autonomous Radiometer (ISAR) was developed to provide reference data for the validation of satellite Sea Surface Temperature at the Skin interface (SSTskin) temperature data products, particularly the Advanced Along Track Scanning Radiometer (AATSR). Since March 2004 ISAR instruments have been deployed nearly continuously on ferries crossing the English Channel and the Bay of Biscay, between Portsmouth (UK) and Bilbao/Santander (Spain). The resulting twelve years of ISAR data, including an individual uncertainty estimate for each SST record, are calibrated with traceability to national standards (National Institute of Standards and Technology, USA (NIST) and National Physical Laboratory, Teddigton, UK (NPL), Fiducial Reference Measurements for satellite derived surface temperature product validation (FRM4STS)). They provide a unique independent in situ reference dataset against which to validate satellite derived products. We present results of the AATSR validation, and show the use of ISAR fiducial reference measurements as a common traceable validation data source for both AATSR and Sea and Land Surface Temperature Radiometer (SLSTR). ISAR data were also used to review performance of the Operational Sea Surface Temperature and Sea Ice Analysis (OSTIA) Sea Surface Temperature (SST) analysis before and after the demise of ESA Environmental Satellite (Envisat) when AATSR inputs ceased This demonstrates use of the ISAR reference data set for validating the SST climatologies that will bridge the data gap between AATSR and SLSTR.

  12. Adaptation of anaerobic cultures of E scherichia coli  K‐12 in response to environmental trimethylamine‐N‐oxide

    PubMed Central

    Denby, Katie J.; Rolfe, Matthew D.; Crick, Ellen; Sanguinetti, Guido; Poole, Robert K.

    2015-01-01

    Summary Systematic analyses of transcriptional and metabolic changes occurring when E scherichia coli  K‐12 switches from fermentative growth to anaerobic respiratory growth with trimethylamine‐N‐oxide (TMAO) as the terminal electron acceptor revealed: (i) the induction of torCAD, but not genes encoding alternative TMAO reductases; (ii) transient expression of frmRAB, encoding formaldehyde dehydrogenase; and (iii) downregulation of copper resistance genes. Simultaneous inference of 167 transcription factor (TF) activities implied that transcriptional re‐programming was mediated by 20 TFs, including the transient inactivation of the two‐component system ArcBA; a prediction validated by direct measurement of phosphorylated ArcA. Induction of frmRAB, detection of dimethylamine in culture medium and formaldehyde production when cell‐free extracts were incubated with TMAO suggested the presence of TMAO demethylase activity. Accordingly, the viability of an frmRAB mutant was compromised upon exposure to TMAO. Downregulation of genes involved in copper resistance could be accounted for by TMAO inhibition of Cu(II) reduction. The simplest interpretation of the data is that during adaptation to the presence of environmental TMAO, anaerobic fermentative cultures of E . coli respond by activating the TorTSR regulatory system with consequent induction of TMAO reductase activity, resulting in net oxidation of menaquinone and inhibition of Cu(II) reduction, responses that are sensed by ArcBA and CusRS respectively. PMID:25471524

  13. Novel type of neutron polarization analysis using the multianalyzer-equipment of the three-axes spectrometer PUMA

    NASA Astrophysics Data System (ADS)

    Schwesig, Steffen; Maity, Avishek; Sobolev, Oleg; Ziegler, Fabian; Eckold, Götz

    2018-01-01

    The combination of polarization analysis and multianalyzer system available at the three axes spectrometer PUMA@FRM II allows the simultaneous determination of both spin states of the scattered neutrons and the absolute value of the polarization. The present paper describes the technical details along with the basic formalism used for the precise calibration. Moreover, the performance of this method is illustrated by several test experiments including first polarized inelastic studies of the magnetic excitations of CuO in the multiferroic and the uniaxial antiferromagnetic phases.

  14. Adaptation of anaerobic cultures of Escherichia coli K-12 in response to environmental trimethylamine-N-oxide.

    PubMed

    Denby, Katie J; Rolfe, Matthew D; Crick, Ellen; Sanguinetti, Guido; Poole, Robert K; Green, Jeffrey

    2015-07-01

    Systematic analyses of transcriptional and metabolic changes occurring when Escherichia coli K-12 switches from fermentative growth to anaerobic respiratory growth with trimethylamine-N-oxide (TMAO) as the terminal electron acceptor revealed: (i) the induction of torCAD, but not genes encoding alternative TMAO reductases; (ii) transient expression of frmRAB, encoding formaldehyde dehydrogenase; and (iii) downregulation of copper resistance genes. Simultaneous inference of 167 transcription factor (TF) activities implied that transcriptional re-programming was mediated by 20 TFs, including the transient inactivation of the two-component system ArcBA; a prediction validated by direct measurement of phosphorylated ArcA. Induction of frmRAB, detection of dimethylamine in culture medium and formaldehyde production when cell-free extracts were incubated with TMAO suggested the presence of TMAO demethylase activity. Accordingly, the viability of an frmRAB mutant was compromised upon exposure to TMAO. Downregulation of genes involved in copper resistance could be accounted for by TMAO inhibition of Cu(II) reduction. The simplest interpretation of the data is that during adaptation to the presence of environmental TMAO, anaerobic fermentative cultures of E. coli respond by activating the TorTSR regulatory system with consequent induction of TMAO reductase activity, resulting in net oxidation of menaquinone and inhibition of Cu(II) reduction, responses that are sensed by ArcBA and CusRS respectively. © 2014 Society for Applied Microbiology and John Wiley & Sons Ltd.

  15. PM2.5 Gravimetric Lab Training (2016 NAAMC)

    EPA Pesticide Factsheets

    This training focused on understanding/applying the PM2.5 FRM in 40 CFR part 50, Appendix L and the updated QA Guidance Document 2.12. it was geared primarily for monitoring and QA managers and staff.

  16. A new search for the permanent electric dipole moment of 129Xe at FRM-II

    NASA Astrophysics Data System (ADS)

    Sachdeva, N.; Chupp, T.; Degenkolb, S.; Fierlinger, P.; Kraegloh, E.; Kuchler, F.; Lins, T.; Meinel, J.; Niessen, B.; Stuiber, S.; Terrano, W. A.; Burghoff, M.; Fan, I.; Kilian, W.; Grüneberg, S.; Schnabel, A.; Seifert, F.; Stollfuss, D.; Trahms, L.; Voight, J.; Babcock, E.; Salhi, Z.; Huneau, J.; Singh, J.

    2017-01-01

    CP-violating sources in beyond-the-standard-model physics, necessary to explain baryon asymmetry, give rise to permanent electric dipole moments (EDMs). Precise EDM measurements of the neutron, electron, paramagnetic and diamagnetic atoms constrain CP-violating parameters. The previous limit for the 129Xe EDM is 6 ×10-27 e . cm (95 % CL). The HeXeEDM experiment at FRM-II (Munich Research Reactor) utilizes an ultralow magnetic field in a high-performance magnetically shielded room and 3He comagnetometer to improve the limit by up to three orders of magnitude. In the experiment, hyperpolarized 3He and 129Xe precession signals are detected with a SQUID magnetometer array in the presence of applied electric and magnetic fields. Recent progress will be presented. This work is supported US Department of Energy Grant No. DE FG02 04 ER41331.

  17. The Munich accelerator for fission fragments MAFF

    NASA Astrophysics Data System (ADS)

    Habs, D.; Groß, M.; Assmann, W.; Ames, F.; Bongers, H.; Emhofer, S.; Heinz, S.; Henry, S.; Kester, O.; Neumayr, J.; Ospald, F.; Reiter, P.; Sieber, T.; Szerypo, J.; Thirolf, P. G.; Varentsov, V.; Wilfart, T.; Faestermann, T.; Krücken, R.; Maier-Komor, P.

    2003-05-01

    The Munich Accelerator for Fission Fragments MAFF has been designed for the new Munich research reactor FRM-II. It will deliver several intense beams (˜3×10 11 s -1) of very neutron-rich fission fragments with a final energy of 30 keV (low-energy beam) or energies between 3.7 and 5.9 MeV· A (high-energy beam). Such beams are of interest for the creation of super-heavy elements by fusion reactions, nuclear spectroscopy of exotic nuclei, but they also have a potential for applications, e.g. in medicine. Presently the Munich research reactor FRM-II is ready for operation, but authorities delay the final permission to turn the reactor critical probably till the end of 2002. Only after this final permission the financing of the major parts of MAFF can start. On the other hand all major components have been designed and special components have been tested in separate setups.

  18. A new multiperiodic gamma Doradus variable in Andromedae.

    NASA Astrophysics Data System (ADS)

    Rodríguez, E.; Amado, P. J.; Costa, V.; Suárez, J. C.; Moya, A.; Poretti, E.; López-González, M. J.; Rolland, A.; López de Coca, P.

    gamma Dor-type oscillations have been discovered in the star HD 218427 through simultaneous uvby photometric observations carried out in the year 2003. A few Hbeta -Crawford measurements were also collected for calibration purposes which place this star well-located inside the gamma Dor instability region. Frecuency analysis was carried out for different filters, the combined ``vby'' filter was also used and five frequencies were found as significant with periods ranging between 0.3 and 0.8 days. The recently developed Frequency Ratio Method (FRM, Moya et al. 2005) is used in order to perform a modal identification of the peaks.

  19. Web based collaborative decision making in flood risk management

    NASA Astrophysics Data System (ADS)

    Evers, Mariele; Almoradie, Adrian; Jonoski, Andreja

    2014-05-01

    Stakeholder participation in the development of flood risk management (FRM) plans is essential since stakeholders often have a better understanding or knowledge of the potentials and limitation of their local area. Moreover, a participatory approach also creates trust amongst stakeholders, leading to a successful implementation of measures. Stakeholder participation however has its challenges and potential pitfalls that could lead to its premature termination. Such challenges and pitfalls are the limitation of financial resources, stakeholders' spatial distribution and their interest to participate. Different type of participation in FRM may encounter diverse challenges. These types of participation in FRM can be classified into (1) Information and knowledge sharing (IKS), (2) Consultative participation (CP) or (3) Collaborative decision making (CDM)- the most challenging type of participation. An innovative approach to address these challenges and potential pitfalls is a web-based mobile or computer-aided environment for stakeholder participation. This enhances the remote interaction between participating entities such as stakeholders. This paper presents a developed framework and an implementation of CDM web based environment for the Alster catchment (Hamburg, Germany) and Cranbrook catchment (London, UK). The CDM framework consists of two main stages: (1) Collaborative modelling and (2) Participatory decision making. This paper also highlights the stakeholder analyses, modelling approach and application of General Public License (GPL) technologies in developing the web-based environments. Actual test and evaluation of the environments was through series of stakeholders workshops. The overall results based from stakeholders' evaluation shows that web-based environments can address the challenges and potential pitfalls in stakeholder participation and it enhances participation in flood risk management. The web-based environment was developed within the DIANE-CM project (Decentralised Integrated Analysis and Enhancement of Awareness through Collaborative Modelling and Management of Flood Risk) of the 2nd ERANET CRUE funding initiative.

  20. The high-resolution time-of-flight spectrometer TOFTOF

    NASA Astrophysics Data System (ADS)

    Unruh, Tobias; Neuhaus, Jürgen; Petry, Winfried

    2007-10-01

    The TOFTOF spectrometer is a multi-disc chopper time-of-flight spectrometer for cold neutrons at the research neutron source Heinz Maier-Leibnitz (FRM II). After five reactor cycles of routine operation the characteristics of the instrument are reported in this article. The spectrometer features an excellent signal to background ratio due to its remote position in the neutron guide hall, an elaborated shielding concept and an s-shaped curved primary neutron guide which acts i.a. as a neutron velocity filter. The spectrometer is fed with neutrons from the undermoderated cold neutron source of the FRM II leading to a total neutron flux of ˜1010n/cm2/s in the continuous white beam at the sample position distributed over a continuous and particularly broad wavelength spectrum. A high energy resolution is achieved by the use of high speed chopper discs made of carbon-fiber-reinforced plastic. In the combination of intensity, resolution and signal to background ratio the spectrometer offers new scientific prospects in the fields of inelastic and quasielastic neutron scattering.

  1. Flood Risk and Asset Management

    DTIC Science & Technology

    2011-06-15

    Model cascade could include HEC - RAS , HR BREACH and Dynamic RFSM. Action HRW to consider model coupling and advise DM. It was felt useful to...simple loss of life approach. WL can provide input and advise on USACE LIFESIM approaches. To enable comparison with HEC FRM approaches, it was

  2. Outcomes of ultrasound guided renal mass biopsies.

    PubMed

    Sutherland, Edward L; Choromanska, Agnieszka; Al-Katib, Sayf; Coffey, Mary

    2018-06-01

    The purpose of this study was to evaluate the rate of nondiagnostic ultrasound-guided renal mass biopsies (RMBs) at our institution and to determine what patient, procedural, and focal renal mass (FRM) factors were associated with nondiagnostic ultrasound-guided RMBs. Eighty-two ultrasound-guided renal mass biopsies performed between January 2014 and October 2016 were included in our study. Biopsy outcomes (diagnostic vs. nondiagnostic) and patient, procedural, and FRM characteristics were retrospectively reviewed and recorded. Univariate statistical analyses were performed to identify biopsy characteristics that were indicative of nondiagnostic biopsy. Ultrasound-guided RMBs were diagnostic in 70 out of 82 cases (85%) and non-diagnostic in 12 cases (15%). Among the diagnostic biopsies, 54 (77%) were malignant cases, 94% of which were renal cell carcinoma (RCC). Of the 12 nondiagnostic cases, the final diagnosis was RCC in 4 cases and angiomyolipoma in one case; seven of the nondiagnostic cases were lost to follow-up. A weak association (p = 0.04) was found between the number of needle passes and the biopsy outcome. None of the remaining collected RMB characteristics showed a significant correlation with a diagnostic or nondiagnostic RMB. Six patients (7%) experienced complications. Ultrasound-guided renal mass biopsy is a safe and effective method for the diagnosis of renal masses with a low rate of nondiagnostic outcomes. A nondiagnostic biopsy should not be treated as a surrogate for a diagnosis since a significant number of patients with nondiagnostic biopsies have subsequently been shown to have renal malignancies. Repeat biopsy should be considered in such cases.

  3. The multi-purpose three-axis spectrometer (TAS) MIRA at FRM II

    NASA Astrophysics Data System (ADS)

    Georgii, R.; Weber, T.; Brandl, G.; Skoulatos, M.; Janoschek, M.; Mühlbauer, S.; Pfleiderer, C.; Böni, P.

    2018-02-01

    The cold-neutron three-axis spectrometer MIRA is an instrument optimized for low-energy excitations. Its excellent intrinsic Q-resolution makes it ideal for studying incommensurate magnetic systems (elastic and inelastic). MIRA is at the forefront of using advanced neutron focusing optics such as elliptic guides, which enable the investigation of small samples under extreme conditions. Another advantage of MIRA is the modular assembly allowing for instrumental adaption to the needs of the experiment within a few hours. The development of new methods such as the spin-echo technique MIEZE is another important application at MIRA. Scientific topics include the investigation of complex inter-metallic alloys and spectroscopy on incommensurate magnetic structures.

  4. High-resolution neutron powder diffractometer SPODI at research reactor FRM II

    NASA Astrophysics Data System (ADS)

    Hoelzel, M.; Senyshyn, A.; Juenke, N.; Boysen, H.; Schmahl, W.; Fuess, H.

    2012-03-01

    SPODI is a high-resolution thermal neutron diffractometer at the research reactor Heinz Maier-Leibnitz (FRM II) especially dedicated to structural studies of complex systems. Unique features like a very large monochromator take-off angle of 155° and a 5 m monochromator-sample distance in its standard configuration achieve both high-resolution and a good profile shape for a broad scattering angle range. Two dimensional data are collected by an array of 80 vertical position sensitive 3He detectors. SPODI is well suited for studies of complex structural and magnetic order and disorder phenomena at non-ambient conditions. In addition to standard sample environment facilities (cryostats, furnaces, magnet) specific devices (rotatable load frame, cell for electric fields, multichannel potentiostat) were developed. Thus the characterisation of functional materials at in-operando conditions can be achieved. In this contribution the details of the design and present performance of the instrument are reported along with its specifications. A new concept for data reduction using a 2 θ dependent variable height for the intensity integration along the Debye-Scherrer lines is introduced.

  5. Optimization of a multi-channel parabolic guide for the material science diffractometer STRESS-SPEC at FRM II

    NASA Astrophysics Data System (ADS)

    Rebelo Kornmeier, Joana; Ostermann, Andreas; Hofmann, Michael; Gibmeier, Jens

    2014-02-01

    Neutron strain diffractometers usually use slits to define a gauge volume within engineering samples. In this study a multi-channel parabolic neutron guide was developed to be used instead of the primary slit to minimise the loss of intensity and vertical definition of the gauge volume when using slits placed far away from the measurement position in bulky components. The major advantage of a focusing guide is that the maximum flux is not at the exit of the guide as for a slit system but at the focal point relatively far away from the exit of the guide. Monte Carlo simulations were used to optimise the multi-channel parabolic guide with respect to the instrument characteristics of the diffractometer STRESS-SPEC at the FRM II neutron source. Also the simulations are in excellent agreement with experimental measurements using the optimised multi-channel parabolic guide at the neutron diffractometer. In addition the performance of the guide was compared to the standard slit setup at STRESS-SPEC using a single bead weld sample used in earlier round robin tests for residual strain measurements.

  6. 14 CFR Appendix N to Part 25 - Fuel Tank Flammability Exposure and Reliability Analysis

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... the performance of a flammability reduction means (FRM) if installed. (c) The following definitions... average fuel temperature within the fuel tank or different sections of the tank if the tank is subdivided... the flight time, and the post-flight time is a constant 30 minutes. (c) Flammable. With respect to a...

  7. 14 CFR Appendix N to Part 25 - Fuel Tank Flammability Exposure and Reliability Analysis

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... the performance of a flammability reduction means (FRM) if installed. (c) The following definitions... average fuel temperature within the fuel tank or different sections of the tank if the tank is subdivided... the flight time, and the post-flight time is a constant 30 minutes. (c) Flammable. With respect to a...

  8. 24 CFR Appendix B to Part 1000 - IHBG Block Grant Formula Mechanisms

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... weighted average for AEL (NAEL). The FMR factor is also defined in § 1000.302 as the relative difference between a local area Fair Market Rent (FMR) and the national weighted average for FMR. OPSUB = [LR * LRSUB... FMR Factor weighted by national average of AEL Factor and FRM Factor. AEL FACTOR = AEL/NAEL. AEL...

  9. Improved sample manipulation at the STRESS-SPEC neutron diffractometer using an industrial 6-axis robot for texture and strain analyses

    NASA Astrophysics Data System (ADS)

    Randau, C.; Brokmeier, H. G.; Gan, W. M.; Hofmann, M.; Voeller, M.; Tekouo, W.; Al-hamdany, N.; Seidl, G.; Schreyer, A.

    2015-09-01

    The materials science neutron diffractometer STRESS-SPEC located at FRM II is a dedicated instrument for strain and pole figure measurements. Both methods make complementary demands on sample handling. On one hand pole figure measurements need a high degree of freedom to orient small samples and on the other hand in strain investigations it is often necessary to handle large and heavy components. Therefore a robot based sample positioning system was developed, which has the capability to provide both possibilities. Based on this new robot system further developments like a full automated sample changer system for texture measurements were accomplished. Moreover this system opens the door for combined strain and texture analysis at STRESS-SPEC.

  10. The multi-purpose three-axis spectrometer (TAS) MIRA at FRM II

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Georgii, Robert; Weber, Tobias; Brandl, Georg

    The cold-neutron three-axis spectrometer MIRA is an instrument optimized for low-energy excitations. Its excellent intrinsic $Q$-resolution makes it ideal for studying incommensurate magnetic systems (elastic and inelastic). MIRA is at the forefront of using advanced neutron focusing optics such as elliptic guides, which enable the investigation of small samples under extreme conditions. Another advantage of MIRA is the modular assembly allowing for instrumental adaption to the needs of the experiment within a few hours. The development of new methods such as the spin-echo technique MIEZE is another important application at MIRA. Finally, scientific topics include the investigation of complex inter-metallicmore » alloys and spectroscopy on incommensurate magnetic structures.« less

  11. Urban Flood Risk Insurance Models as a Strategy for Proactive Water Management Policies

    NASA Astrophysics Data System (ADS)

    Graciosa, M. C.; Mendiondo, E. M.

    2006-12-01

    To improve the water management through hydrological sciences, novel integration strategies could be underpinned to bridge up both engineering and economics. This is especially significant in developing nations where hydrologic extremes are expressive while the financial resources to mitigate that variability are scarce. One example of this problem is related to floods and their global and regional consequences. Floods mainly cause disasters in terms of human and material losses. In 2002, more than 30% of extreme climatic events occurred worldwide were floods, representing 42% of fatalities and 66% of material losses, mostly related to reactive policies. Throughout the last century, hydrological variability and rapidly growing of urban areas have developed new environmental problems in Brazilian cities, such as inundation occurrences on non-planned river basins. One of the causes of flood impacts is that public funds (national, state or municipal) have barely introduced wise proactive polices to follow up rapidly growing urban areas. Inexistent flood-risk-transfer mechanisms have caused the so-called `flood poverty cycle' due to reactive polices that have been increasing flood losses and, sometimes, became flood disasters. Flood risk management (FRM) is part of pro-active policies to mitigate inundation losses, in order to sustain environmental, social and economic aspects. Concepts and principles of FRM are part of a process that encompasses three phases: (1) preparedness stage, that consists in structural and non-structural actions to prevent and protect potential risk areas, such as early warning systems and scenarios development; (2) control stage, that refers to help actions and protection facilities during the event, and (3) restoration stage, that is related to rebuild affected areas, restore the river dynamics and transfer the socio-economic risks through flood insurances. Flood risk insurances agree to the goals of losses mitigation programs. Their use is more common in basins affected by alluvial floods. However, most of losses occur in urban areas, as a consequence of flash floods. Quantification of losses is an important basis of flood mitigation programs. It is also a complex task, which involves setting values on not easily quantifiable goods and determining risk and damage curves. This work proposes a flood insurance risk model coupled with a hydrological model as an incentive-based mechanism for achieving economically efficient flood management to be applied in Brazilian urban basins. It consists of integrating an insurance model and hydrological modeling of peak discharge warnings. It sets up curves, such as: water level versus discharge, water level versus inundation areas, and inundation area versus damage. It considers the prediction of future scenarios in order to evaluate the behavior of the insurance fund under climate variability. By using different probability distribution is compared the solvency and efficiency of the flood insurance fund for each premium-covered situation. The methodology is outlined to provide resources for the FRM restoration phase. Results are depicted from an experimental river basin sited on a rapid growing urban area, with some lessons learned valid to approach in other urban basins. This example is envisaged to foster resilience in the integration of hydrological science with policy and economic approaches. KEY WORDS: Flood risks management; flood insurance; hydrological modeling.

  12. 46 CFR Appendix A to Part 520 - Standard Terminology and Codes

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... DTB Firkin FIR Flo-Bin FLO Frame FRM Flask FSK Forward Reel FWR Garment on Hanger GOH Heads of Beef... Private Vehicle POV Pipe Rack PRK Quarters of Beef QTR Rail (semiconductor) RAL Rack RCK Reel REL Roll ROL Reverse Reel RVR Sack SAK Shook SHK Sides of Beef SID Skid SKD Skid, Elev, Lift Trk SKE Sleeve SLV Spin...

  13. 46 CFR Appendix A to Part 520 - Standard Terminology and Codes

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... DTB Firkin FIR Flo-Bin FLO Frame FRM Flask FSK Forward Reel FWR Garment on Hanger GOH Heads of Beef... Private Vehicle POV Pipe Rack PRK Quarters of Beef QTR Rail (semiconductor) RAL Rack RCK Reel REL Roll ROL Reverse Reel RVR Sack SAK Shook SHK Sides of Beef SID Skid SKD Skid, Elev, Lift Trk SKE Sleeve SLV Spin...

  14. 46 CFR Appendix A to Part 520 - Standard Terminology and Codes

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... DTB Firkin FIR Flo-Bin FLO Frame FRM Flask FSK Forward Reel FWR Garment on Hanger GOH Heads of Beef... Private Vehicle POV Pipe Rack PRK Quarters of Beef QTR Rail (semiconductor) RAL Rack RCK Reel REL Roll ROL Reverse Reel RVR Sack SAK Shook SHK Sides of Beef SID Skid SKD Skid, Elev, Lift Trk SKE Sleeve SLV Spin...

  15. 46 CFR Appendix A to Part 520 - Standard Terminology and Codes

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... DTB Firkin FIR Flo-Bin FLO Frame FRM Flask FSK Forward Reel FWR Garment on Hanger GOH Heads of Beef... Private Vehicle POV Pipe Rack PRK Quarters of Beef QTR Rail (semiconductor) RAL Rack RCK Reel REL Roll ROL Reverse Reel RVR Sack SAK Shook SHK Sides of Beef SID Skid SKD Skid, Elev, Lift Trk SKE Sleeve SLV Spin...

  16. 46 CFR Appendix A to Part 520 - Standard Terminology and Codes

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... DTB Firkin FIR Flo-Bin FLO Frame FRM Flask FSK Forward Reel FWR Garment on Hanger GOH Heads of Beef... Private Vehicle POV Pipe Rack PRK Quarters of Beef QTR Rail (semiconductor) RAL Rack RCK Reel REL Roll ROL Reverse Reel RVR Sack SAK Shook SHK Sides of Beef SID Skid SKD Skid, Elev, Lift Trk SKE Sleeve SLV Spin...

  17. Clinical Investigation Program Annual Progress Report.

    DTIC Science & Technology

    1984-09-30

    145 80/201 Camparison of Cardiac Output and Left Ventricular Stroke Work Before and After Standard Anesthesia Induction of Patients Unrergoing...Role of Minimal Surgical Debridement in the Treatment of Vesicant Extravasations. (O)(PR) ....... 159 84/200 Prevention of Macular Injury frm High...fram or Help Prevent Bone Injury .(C)(P)(PR) .................... 171 80/302 Rapid Detection of Bacterial Antigens in Patient Specimens Using

  18. 40 CFR Appendix D to Part 58 - Network Design Criteria for Ambient Air Quality Monitoring

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... residential district. In this case, one location is representative of a neighborhood of small scale sites and... least one of the required FRM/FEM/ARM monitors is itself a continuous FEM or ARM monitor in which case... studies. 4.7.5Special Network Considerations Required When Using PM2.5 Spatial Averaging Approaches. (a...

  19. 40 CFR Appendix D to Part 58 - Network Design Criteria for Ambient Air Quality Monitoring

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... residential district. In this case, one location is representative of a neighborhood of small scale sites and... least one of the required FRM/FEM/ARM monitors is itself a continuous FEM or ARM monitor in which case... studies. 4.7.5Special Network Considerations Required When Using PM2.5 Spatial Averaging Approaches. (a...

  20. 40 CFR Appendix D to Part 58 - Network Design Criteria for Ambient Air Quality Monitoring

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... residential district. In this case, one location is representative of a neighborhood of small scale sites and... least one of the required FRM/FEM/ARM monitors is itself a continuous FEM or ARM monitor in which case... studies. 4.7.5Special Network Considerations Required When Using PM2.5 Spatial Averaging Approaches. (a...

  1. Programmable Image Processing Element.

    DTIC Science & Technology

    1980-11-01

    appicaIOn IS g-ivenl Ill A parallel ss OIL irmnat . Ilece. thle block diagramm of- [iguire 3 is modifwid to chanlge the 1iput data frmM pl)JIll oiit to...is slownl In I iguie -42. -1h1 breaid- board oi~s of, nine iniput latche\\,. niruc pifdle-ini seri:il-oiit shl’t reitcs I fast 5 1-’ 1 2--ilt

  2. POWTEX Neutron Diffractometer at FRM II - New Perspectives in Rock Deformation and Recrystallisation Analysis

    NASA Astrophysics Data System (ADS)

    Walter, J. M.; Stipp, M.; Ullemeyer, K.; Klein, H.; Leiss, B.; Hansen, B.; Kuhs, W. F.

    2011-12-01

    Neutron diffraction has become a routine method in Geoscience for the quantitative analysis of crystallographic preferred orientations (CPOs) and for (experimental) powder diffraction. Quantitative texture analysis is a common tool for the investigation of fabric development in mono- and polyphase rocks, their deformation histories and kinematics. Furthermore the quantitative characterization of anisotropic physical properties by bulk texture measurements can be achieved due to the high penetration capabilities of neutrons. To cope with increasing needs for beam time at neutron diffraction facilities with the corresponding technical characteristics and equipment, POWTEX (POWder and TEXture Diffractometer) is designed as a high-intensity diffractometer at the neutron research reactor FRM II in Garching, Germany by groups from the RWTH Aachen, Forschungszentrum Jülich and the University of Göttingen. Complementary to existing neutron diffractometers (SKAT at Dubna, Russia; GEM at ISIS, UK; HIPPO at Los Alamos, USA; D20 at ILL, France; and the local STRESS-SPEC and SPODI at FRM II) the layout of POWTEX is focused on fast (texture) measurements for either time-resolved experiments or the measurement of larger sample series as necessary for the study of large scale geological structures. By utilizing a range of neutron wavelengths simultaneously (TOF-technique), a high flux (~1 x 107 n/cm2s) and a high detector coverage ( 9.8 sr) effective texture measurements without sample tilting and rotation are possible. Furthermore the instrument and the angular detector resolution is sufficient for strong recrystallisation textures as well as weak textures of polyphase rocks. Thereby large sample environments will be implemented at POWTEX allowing in-situ time-resolved texture measurements during deformation experiments on rocksalt, ice and other materials. Furthermore a furnace for 3D-recrystallisation analysis of single grains will be realized complementary to the furnace that already exists for fine grained materials at the synchrotron beamline BW5 at HASYLAB, Germany (e.g. Klein et al. 2009). The in-situ triaxial deformation apparatus is operated by a uniaxial spindle drive with a maximum axial load of 200 kN, which will be redesigned to minimize shadowing effects on the detector. The HT experiments will be carried out in uniaxial compression or extension and an upgrade to triaxial deformation conditions is envisaged. The load frame can alternatively be used for ice deformation by inserting a cryostat cell for temperatures down to 77 K with a triaxial apparatus allowing also simple shear experiments on ice. Strain rates range between 10-8 and 10-3 s-1 reaching to at least 50 % axial strain. The furnace for the recrystallization analysis will be a mirror furnace with temperatures up to 1500° C, which will be rotatable around a vertical axis to obtain the required stereologic orientation information.

  3. Calibration of a Three Wavelength Lidar for Size Discriminated Ambient Particulate Measurement

    NASA Astrophysics Data System (ADS)

    Martin, R. S.; Zavyalov, V.; Bingham, G. E.; Marchant, C.; Herron, J.; Jones, D.; Bowman, J.; Moore, K. D.

    2007-12-01

    A three wavelength Lidar has been developed at Utah State University's Space Dynamics Laboratory for the measurement of size segregated ambient particulate matter concentrations as part of the AgLite program. The AgLite program, primarily funded by the U.S. Department of Agriculture's Agricultural Research Service, was developed to quantify particulate emissions from diffuse area sources, such as those typically found around confined animal feeding operations (CAFOs) and tillage operations. The Lidar system is capable of scanning horizontally and vertically across a suspected source area and can identify both spatial and temporal concentration fields which, when combined with locally measured wind field data, can be used to derive source emission estimates. The Lidar measures the relative magnitude of optical scattering by the atmosphere, which is a function of aerosol concentration. A Lidar scan around a source area gives a map of relative aerosol concentration. During an operational experiment, a scan is calibrated by point-sensors collocated with one or more points of the Lidar scan. In order to minimize potential systematic errors, a detailed calibration experiment was designed to compare Lidar return signals with Met One Instruments 8-channel Optical Particle Counters (Model 9722) and Airmetrics MiniVol filter-based samplers configured for collection of TSP, PM10, PM2.5, and PM1. The Lidar calibration experiment was performed in July 2007 at a farm owned and operated by Utah State University near Cache Junction, Utah. Multiple datasets were collected during which the Lidar moved between three stares, each a minute in duration, that were collocated with a cluster of MiniVols sampling the four size fractionations and an OPC. Sampler duration was between three and eight hours, depending upon background particulate concentrations. Prior to comparison of these instruments with the Lidar, the MiniVols and OPCs were compared against collocated PM2.5 and PM10 Federal Reference Method (FRM) samplers operated by the State of Utah Division of Air Quality at the designated air quality sampling site in Logan, Utah to ensure the accuracy of the point sensors. Preliminary analysis demonstrates the average concentrations measured by the MiniVols were within eight percent of the concentrations measured by the FRM samplers at ambient levels greater than 10 μg m-3 for PM2.5 and 14 percent for PM10 at 35 μg m-3. The volume-based concentration determined from the OPCs demonstrated a consistent relationship with the MiniVols filter-based mass concentrations across the observed size ranges. Results of the Lidar comparison with the OPCs and MiniVols will also be presented.

  4. DOAS (differential optical absorption spectroscopy) urban pollution measurements

    NASA Astrophysics Data System (ADS)

    Stevens, Robert K.; Vossler, T. L.

    1991-05-01

    During July and August of 1990, a differential optical absorption spectrometer (DOAS) made by OPSIS Inc. was used to measure gaseous air pollutants over three separate open paths in Atlanta, GA. Over path 1 (1099 m) and path 2 (1824 m), ozone (03), sulfur dioxide (SO2) nitrogen dioxide (NO2), nitrous acid (HNO2) formaldehyde (HCHO), benzene, toluene, and o-xylene were measured. Nitric oxide (NO) and ammonia (NH3) were monitored over path 3 (143 m). The data quality and data capture depended on the compound being measured and the path over which it was measured. Data quality criteria for each compound were chosen such that the average relative standard deviation would be less than 25%. Data capture ranged from 43% for o-xylene for path 1 to 95% for ozone for path 2. Benzene, toluene, and o-xylene concentrations measured over path 2, which crossed over an interstate highway, were higher than concentrations measured over path 1, implicating emissions from vehicles on the highway as a significant source of these compounds. Federal Reference Method (FRN) instruments were located near the DOAS light receivers and measurements of 03, NO2, and NO were made concurrently with the DOAS. Correlation coefficients greater than 0.85 were obtained between the DOAS and FRM's; however, there was a difference between the mean values obtained by the two methods for 03 and NO. A gas chromatograph for measuring volatile organic compounds was operated next to the FRN's. Correlation coefficients of about 0.66 were obtained between the DOAS and GC measurements of benzene and o- xylene. However, the correlation coefficient between the DOAS and GC measurements of toluene averaged only 0.15 for the two DOAS measurement paths. The lack of correlation and other factors indicate the possibility of a localized source of toluene near the GC. In general, disagreements between the two measurement methods could be caused by atmospheric inhomogeneities or interferences in the DOAS and other methods.

  5. 40 CFR Table F-3 to Subpart F of... - Critical Parameters of Idealized Ambient Particle Size Distributions

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Ambient Particle Size Distributions F Table F-3 to Subpart F of Part 53 Protection of Environment... Ambient Particle Size Distributions Idealized Distribution Fine Particle Mode MMD (µm) Geo. Std. Dev. Conc. (µg/m3) Coarse Particle Mode MMD (µm) Geo. Std. Dev. Conc. (µg/m3) PM2.5/PM10 Ratio FRM Sampler...

  6. 40 CFR Table F-3 to Subpart F of... - Critical Parameters of Idealized Ambient Particle Size Distributions

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Ambient Particle Size Distributions F Table F-3 to Subpart F of Part 53 Protection of Environment... Ambient Particle Size Distributions Idealized Distribution Fine Particle Mode MMD (µm) Geo. Std. Dev. Conc. (µg/m 3) Coarse Particle Mode MMD (µm) Geo. Std. Dev. Conc. (µg/m 3) PM 2.5/PM 10 Ratio FRM Sampler...

  7. 40 CFR Table F-3 to Subpart F of... - Critical Parameters of Idealized Ambient Particle Size Distributions

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Ambient Particle Size Distributions F Table F-3 to Subpart F of Part 53 Protection of Environment... Ambient Particle Size Distributions Idealized Distribution Fine Particle Mode MMD (µm) Geo. Std. Dev. Conc. (µg/m3) Coarse Particle Mode MMD (µm) Geo. Std. Dev. Conc. (µg/m3) PM2.5/PM10 Ratio FRM Sampler...

  8. 40 CFR Table F-3 to Subpart F of... - Critical Parameters of Idealized Ambient Particle Size Distributions

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Ambient Particle Size Distributions F Table F-3 to Subpart F of Part 53 Protection of Environment... Ambient Particle Size Distributions Idealized Distribution Fine Particle Mode MMD (µm) Geo. Std. Dev. Conc. (µg/m3) Coarse Particle Mode MMD (µm) Geo. Std. Dev. Conc. (µg/m3) PM2.5/PM10 Ratio FRM Sampler...

  9. 40 CFR Table F-3 to Subpart F of... - Critical Parameters of Idealized Ambient Particle Size Distributions

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Ambient Particle Size Distributions F Table F-3 to Subpart F of Part 53 Protection of Environment... Ambient Particle Size Distributions Idealized Distribution Fine Particle Mode MMD (µm) Geo. Std. Dev. Conc. (µg/m3) Coarse Particle Mode MMD (µm) Geo. Std. Dev. Conc. (µg/m3) PM 2.5/PM 10 Ratio FRM Sampler...

  10. Future Technology-Driven Revolutions in Military Operations. Results of a Workshop

    DTIC Science & Technology

    1994-01-01

    sensor missions. "• Biomolecular Electronics - The use of techniques from molecular biology and biotechnology to develop new molecular electronic materials...34* Biomolecular electronics - The use of techniques from molecular biology and biotechnology to develop new molecular electronic materials, components, and...occurring in molecular biology . 42 Biotechnology Molecular Biologists Arm Develoni "Magical" Caoabilitles "• To mynthsieh genm (frm satch) with conboi

  11. Acquiring Procedural Skills from Lesson Sequences.

    DTIC Science & Technology

    1985-08-13

    Teachers of Mathematics . Washington, D)C: NCTM . Brueckner, I..J. (1930) Diagnostic aund remedial teaching in arithmetic. Philadelphia. PA: Winston. Burton...arithmetic and algebra, fr-m multi-lesson curricula. The central hypothesis is that students and teachers obey cc: :-.entions that cause the goal hierarchy...students and • . teachers obey conventions that cause the goal hierarchy of the acquired procedure to be a particular structural function of the sequential

  12. Design of a Hypermedia-Based Educating System for the Construction of Knowledge

    DTIC Science & Technology

    1989-09-01

    the variety they confront, promote short-term learning . This thesis provides the required background for developing an educating system which promotes...an effective educating system stems frm ever-increasing requirements for learning . Ine Total Quality Management (TQM) program, a Department of Defense...Japan has realized that best efforts ’nly pay off when the workforce is properly educated . Learning has become a pivotal element in the Japanese

  13. The Copernicus S5P Mission Performance Centre / Validation Data Analysis Facility for TROPOMI operational atmospheric data products

    NASA Astrophysics Data System (ADS)

    Compernolle, Steven; Lambert, Jean-Christopher; Langerock, Bavo; Granville, José; Hubert, Daan; Keppens, Arno; Rasson, Olivier; De Mazière, Martine; Fjæraa, Ann Mari; Niemeijer, Sander

    2017-04-01

    Sentinel-5 Precursor (S5P), to be launched in 2017 as the first atmospheric composition satellite of the Copernicus programme, carries as payload the TROPOspheric Monitoring Instrument (TROPOMI) developed by The Netherlands in close cooperation with ESA. Designed to measure Earth radiance and solar irradiance in the ultraviolet, visible and near infrared, TROPOMI will provide Copernicus with observational data on atmospheric composition at unprecedented geographical resolution. The S5P Mission Performance Center (MPC) provides an operational service-based solution for various QA/QC tasks, including the validation of S5P Level-2 data products and the support to algorithm evolution. Those two tasks are to be accomplished by the MPC Validation Data Analysis Facility (VDAF), one MPC component developed and operated at BIRA-IASB with support from S[&]T and NILU. The routine validation to be ensured by VDAF is complemented by a list of validation AO projects carried out by ESA's S5P Validation Team (S5PVT), with whom interaction is essential. Here we will introduce the general architecture of VDAF, its relation to the other MPC components, the generic and specific validation strategies applied for each of the official TROPOMI data products, and the expected output of the system. The S5P data products to be validated by VDAF are diverse: O3 (vertical profile, total column, tropospheric column), NO2 (total and tropospheric column), HCHO (tropospheric column), SO2 (column), CO (column), CH4 (column), aerosol layer height and clouds (fractional cover, cloud-top pressure and optical thickness). Starting from a generic validation protocol meeting community-agreed standards, a set of specific validation settings is associated with each data product, as well as the appropriate set of Fiducial Reference Measurements (FRM) to which it will be compared. VDAF collects FRMs from ESA's Validation Data Centre (EVDC) and from other sources (e.g., WMO's GAW, NDACC and TCCON). Data manipulations on satellite and FRM data (format conversion, filtering, co-location, regridding and vertical smoothing) are performed by the open source software HARP, while more specific manipulations apply in-house routines. The paper concludes with a short description of expected outputs of the system.

  14. An Analysis of the United States Air Force Nonpoint Source Water Pollution Abatement Program

    DTIC Science & Technology

    1990-09-01

    salts and other minerals. The nmoff frm barnyards and confined feedlots carries organic matter, amcmia, fecal bacteria and other microorganisms, and...nutrients in fertilizers used in lawn care, fecal bacteria from animals (mainly pets and birds), and pesticides are all contained in this runoff...application of pesticides and fertilizers. Less of these products can be applied at optinun intervals and under the proper conditions to reduce the

  15. Peak broadening and peak shift pole figures investigations by STRESS-SPEC diffractometer at FRM II

    NASA Astrophysics Data System (ADS)

    Gan, W. M.; Randau, C.; Hofmann, M.; Brokmeier, H. G.; Mueller, M.; Schreyer, A.

    2012-02-01

    This paper studied for the first time peak intensity, peak position and FHWM pole figures with one time measurement at the neutron diffractometer STRESS-SPEC via in-situ tensile deformation on austenitic steel. Fibre distribution with its evolution from central tensile direction to normal direction of these three kinds of pole figures was obtained. Variation of peak position and FWHM can be correlated to the reorientation of the texture component.

  16. Clinical and Epidemiological Studies on Rickettsial Infections.

    DTIC Science & Technology

    1980-06-01

    investigations currently or fo Tly undertaken with the collaboration or spotof the following or n’iztiona- 1) In, Ethiopia : Naval Medical Research Uit-S.. 2) In B...data from the continuing studies in Burma ocanplement and extend our earlier investigati6ns in Ethiopia , we now sumarize those results frm the Ethiopian...TESTS COMPARING RATES IN RATTUS RATTUS A14D MUS MUSCULUS WITH OTHER RODENTS (INDOORS AND OUTDOORS) IN ETHIOPIA , WITH INDICATION OP THEIR MAJOR

  17. High conductivity a-C:N thin films prepared by electron gun evaporation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rebollo-Plata, B.; Lozada-Morales, R.; Palomino-Merino, R.

    2007-08-15

    By employing electron beam evaporation, amorphous carbon nitride (a-C:N) thin films, with a low nitrogen content ({approx} 1%), were prepared on Si(110) and glass substrates at about 150 deg. C. The source was a graphite target and an ambient of N{sub 2} was introduced into the growing chamber. The source-substrate distance (SSD) was the main parameter that was intentionally varied. Electron dispersion spectroscopy measurements indicate the nitrogen concentration in the layer as {approx} 1%. The dark electrical conductivity ({sigma}) of layers was very sensitive to SSD variation, changing up to six orders of magnitude when this parameter was varied frommore » 10.5 to 23.5 cm. A maximum value of {sigma} = 1 x 10{sup 3} {omega}{sup -1} cm{sup -1} at room temperature was obtained when the SSD was equal to 15.5 cm. We have deduced that, in accordance with the Ferrari-Robertson model (FRM), our samples are localized in the second stage of the amorphization trajectory of FRM. When the SSD increases the C atoms have more probability to collide with N{sub 2} molecules, and the content of nitrogen in the a-C film increases. The amorphization trajectory followed by the films with an SSD increase is from nanocrystalline graphite to amorphous carbon. The changes in the amorphization are due to the nitrogen content in the layers.« less

  18. Optimizing the triple-axis spectrometer PANDA at the MLZ for small samples and complex sample environment conditions

    NASA Astrophysics Data System (ADS)

    Utschick, C.; Skoulatos, M.; Schneidewind, A.; Böni, P.

    2016-11-01

    The cold-neutron triple-axis spectrometer PANDA at the neutron source FRM II has been serving an international user community studying condensed matter physics problems. We report on a new setup, improving the signal-to-noise ratio for small samples and pressure cell setups. Analytical and numerical Monte Carlo methods are used for the optimization of elliptic and parabolic focusing guides. They are placed between the monochromator and sample positions, and the flux at the sample is compared to the one achieved by standard monochromator focusing techniques. A 25 times smaller spot size is achieved, associated with a factor of 2 increased intensity, within the same divergence limits, ± 2 ° . This optional neutron focusing guide shall establish a top-class spectrometer for studying novel exotic properties of matter in combination with more stringent sample environment conditions such as extreme pressures associated with small sample sizes.

  19. Performance Evaluation of "Low-cost" Sensors for Measuring Gaseous and Particle Air Pollutants: Results from Two Years of Field and Laboratory Testing

    NASA Astrophysics Data System (ADS)

    Feenstra, B. J.; Polidori, A.; Tisopulos, L.; Papapostolou, V.; Zhang, H.; Pathmanabhan, J.

    2016-12-01

    In recent years great progress has been made in development of low-cost miniature air quality sensing technologies. Such low-cost sensors offer a prospect of providing a real-time spatially dense information on pollutants, however, the quality of the data produced by these sensors is so far untested. In an effort to inform the general public about the actual performance of commercially available low-cost air quality sensors, in June 2014 the South Coast Air Quality Management District (SCAQMD) has established the Air Quality Sensor Performance Evaluation Center (AQ-SPEC). This program performs a thorough characterization of low-cost sensors under ambient (in the field) and controlled (in the laboratory) conditions. During the field testing, air quality sensors are operated side-by-side with Federal Reference Methods and Federal Equivalent Methods (FRM and FEM, respectively), which are routinely used to measure the ambient concentration of gaseous or particle pollutants for regulatory purposes. Field testing is conducted at two of SCAQMD's existing air monitoring stations, one in Rubidoux and one near the I-710 freeway. Sensors that demonstrate an acceptable performance in the field are brought back to the lab where a "characterization chamber" is used to challenge these devices with known concentrations of different particle and gaseous pollutants under different temperature and relative humidity levels. Testing results for each sensor are then summarized in a technical report and, along with other relevant information, posted online on a dedicated website (www.aqmd.gov/aq-spec) to educate the public about the capabilities of commercially available sensors and their potential applications. During this presentation, the results from two years of field and laboratory testing will be presented. The major strengths and weaknesses of some of the most commonly available particle and gaseous sensors will be discussed.

  20. Intercomparison of an Aerosol Chemical Speciation Monitor (ACSM) with ambient fine aerosol measurements in downtown Atlanta, Georgia

    NASA Astrophysics Data System (ADS)

    Budisulistiorini, S. H.; Canagaratna, M. R.; Croteau, P. L.; Baumann, K.; Edgerton, E. S.; Kollman, M. S.; Ng, N. L.; Verma, V.; Shaw, S. L.; Knipping, E. M.; Worsnop, D. R.; Jayne, J. T.; Weber, R. J.; Surratt, J. D.

    2014-07-01

    Currently, there are a limited number of field studies that evaluate the long-term performance of the Aerodyne Aerosol Chemical Speciation Monitor (ACSM) against established monitoring networks. In this study, we present seasonal intercomparisons of the ACSM with collocated fine aerosol (PM2.5) measurements at the Southeastern Aerosol Research and Characterization (SEARCH) Jefferson Street (JST) site near downtown Atlanta, GA, during 2011-2012. Intercomparison of two collocated ACSMs resulted in strong correlations (r2 > 0.8) for all chemical species, except chloride (r2 = 0.21) indicating that ACSM instruments are capable of stable and reproducible operation. In general, speciated ACSM mass concentrations correlate well (r2 > 0.7) with the filter-adjusted continuous measurements from JST, although the correlation for nitrate is weaker (r2 = 0.55) in summer. Correlations of the ACSM NR-PM1 (non-refractory particulate matter with aerodynamic diameter less than or equal to 1 μm) plus elemental carbon (EC) with tapered element oscillating microbalance (TEOM) PM2.5 and Federal Reference Method (FRM) PM1 mass are strong with r2 > 0.7 and r2 > 0.8, respectively. Discrepancies might be attributed to evaporative losses of semi-volatile species from the filter measurements used to adjust the collocated continuous measurements. This suggests that adjusting the ambient aerosol continuous measurements with results from filter analysis introduced additional bias to the measurements. We also recommend to calibrate the ambient aerosol monitoring instruments using aerosol standards rather than gas-phase standards. The fitting approach for ACSM relative ionization for sulfate was shown to improve the comparisons between ACSM and collocated measurements in the absence of calibrated values, suggesting the importance of adding sulfate calibration into the ACSM calibration routine.

  1. a Theoretical and Experimental Investigation of 1/F Noise in the Alpha Decay Rates of AMERICIUM-241.

    NASA Astrophysics Data System (ADS)

    Pepper, Gary T.

    New experimental methods and data analysis techniques were used to investigate the hypothesis of the existence of 1/f noise in a alpha particle emission rates for ^{241}Am. Experimental estimates of the flicker floor were found to be almost two orders of magnitude less than Handel's theoretical prediction and previous measurements. The existence of a flicker floor for ^{57}Co decay, a process for which no charged particles are emitted, indicate that instrumental instability is likely responsible for the values of the flicker floor obtained. The experimental results and the theoretical arguments presented indicate that a re-examination of Handel's theory of 1/f noise is appropriate. Methods of numerical simulation of noise processes with a 1/f^{rm n} power spectral density were developed. These were used to investigate various statistical aspects of 1/f ^{rm n} noise. The probability density function for the Allan variance was investigated in order to establish confidence limits for the observations made. The effect of using grouped (correlated) data, for evaluating the Allan variance, was also investigated.

  2. Construction of an integrated social vulnerability index in urban areas prone to flash flooding

    NASA Astrophysics Data System (ADS)

    Aroca-Jimenez, Estefania; Bodoque, Jose Maria; Garcia, Juan Antonio; Diez-Herrero, Andres

    2017-09-01

    Among the natural hazards, flash flooding is the leading cause of weather-related deaths. Flood risk management (FRM) in this context requires a comprehensive assessment of the social risk component. In this regard, integrated social vulnerability (ISV) can incorporate spatial distribution and contribution and the combined effect of exposure, sensitivity and resilience to total vulnerability, although these components are often disregarded. ISV is defined by the demographic and socio-economic characteristics that condition a population's capacity to cope with, resist and recover from risk and can be expressed as the integrated social vulnerability index (ISVI). This study describes a methodological approach towards constructing the ISVI in urban areas prone to flash flooding in Castilla y León (Castile and León, northern central Spain, 94 223 km2, 2 478 376 inhabitants). A hierarchical segmentation analysis (HSA) was performed prior to the principal components analysis (PCA), which helped to overcome the sample size limitation inherent in PCA. ISVI was obtained from weighting vulnerability factors based on the tolerance statistic. In addition, latent class cluster analysis (LCCA) was carried out to identify spatial patterns of vulnerability within the study area. Our results show that the ISVI has high spatial variability. Moreover, the source of vulnerability in each urban area cluster can be identified from LCCA. These findings make it possible to design tailor-made strategies for FRM, thereby increasing the efficiency of plans and policies and helping to reduce the cost of mitigation measures.

  3. The Thermal Neutron Beam Option for NECTAR at MLZ

    NASA Astrophysics Data System (ADS)

    Mühlbauer, M. J.; Bücherl, T.; Genreith, C.; Knapp, M.; Schulz, M.; Söllradl, S.; Wagner, F. M.; Ehrenberg, H.

    The beam port SR10 at the neutron source FRM II of Heinz Maier-Leibnitz Zentrum (MLZ) is equipped with a moveable assembly of two uranium plates, which can be placed in front of the entrance window of the beam tube via remote control. With these plates placed in their operating position the thermal neutron spectrum produced by the neutron source FRM II is converted to fission neutrons with 1.9 MeV of mean energy. This fission neutron spectrum is routinely used for medical applications at the irradiation facility MEDAPP, for neutron radiography and tomography experiments at the facility NECTAR and for materials testing. If, however, the uranium plates are in their stand-by position far off the tip of the beam tube and the so-called permanent filter for thermal neutrons is removed, thermal neutrons originating from the moderator tank enter the beam tube and a thermal spectrum becomes available for irradiation or activation of samples. By installing a temporary flight tube the beam may be used for thermal neutron radiography and tomography experiments at NECTAR. The thermal neutron beam option not only adds a pure thermal neutron spectrum to the energy ranges available for neutron imaging at MLZ instruments but it also is an unique possibility to combine two quite different neutron energy ranges at a single instrument including their respective advantages. The thermal neutron beam option for NECTAR is funded by BMBF in frame of research project 05K16VK3.

  4. Comparing NEO Search Telescopes

    NASA Astrophysics Data System (ADS)

    Myhrvold, Nathan

    2016-04-01

    Multiple terrestrial and space-based telescopes have been proposed for detecting and tracking near-Earth objects (NEOs). Detailed simulations of the search performance of these systems have used complex computer codes that are not widely available, which hinders accurate cross-comparison of the proposals and obscures whether they have consistent assumptions. Moreover, some proposed instruments would survey infrared (IR) bands, whereas others would operate in the visible band, and differences among asteroid thermal and visible-light models used in the simulations further complicate like-to-like comparisons. I use simple physical principles to estimate basic performance metrics for the ground-based Large Synoptic Survey Telescope and three space-based instruments—Sentinel, NEOCam, and a Cubesat constellation. The performance is measured against two different NEO distributions, the Bottke et al. distribution of general NEOs, and the Veres et al. distribution of Earth-impacting NEO. The results of the comparison show simplified relative performance metrics, including the expected number of NEOs visible in the search volumes and the initial detection rates expected for each system. Although these simplified comparisons do not capture all of the details, they give considerable insight into the physical factors limiting performance. Multiple asteroid thermal models are considered, including FRM, NEATM, and a new generalized form of FRM. I describe issues with how IR albedo and emissivity have been estimated in previous studies, which may render them inaccurate. A thermal model for tumbling asteroids is also developed and suggests that tumbling asteroids may be surprisingly difficult for IR telescopes to observe.

  5. POWTEX Neutron Diffractometer at FRM II - New Perspectives for In-Situ Rock Deformation Analysis

    NASA Astrophysics Data System (ADS)

    Walter, J. M.; Stipp, M.; Ullemeyer, K.; Klein, H.; Leiss, B.; Hansen, B. T.; Kuhs, W. F.

    2012-04-01

    In Geoscience quantitative texture analysis here defined as the quantitative analysis of the crystallographic preferred orientation (CPO), is a common tool for the investigation of fabric development in mono- and polyphase rocks, their deformation histories and kinematics. Bulk texture measurements also allow the quantitative characterisation of the anisotropic physical properties of rock materials. A routine tool to measure bulk sample volumes is neutron texture diffraction, as neutrons have large penetration capabilities of several cm in geological sample materials. The new POWTEX (POWder and TEXture) Diffractometer at the neutron research reactor FRM II in Garching, Germany is designed as a high-intensity diffractometer by groups from the RWTH Aachen, Forschungszentrum Jülich and the University of Göttingen. Complementary to existing neutron diffractometers (SKAT at Dubna, Russia; GEM at ISIS, UK; HIPPO at Los Alamos, USA; D20 at ILL, France; and the local STRESS-SPEC and SPODI at FRM II) the layout of POWTEX is focused on fast time-resolved experiments and the measurement of larger sample series as necessary for the study of large scale geological structures. POWTEX is a dedicated beam line for geoscientific research. Effective texture measurements without sample tilting and rotation are possible firstly by utilizing a range of neutron wavelengths simultaneously (Time-of-Flight technique) and secondly by the high detector coverage (9.8 sr) and a high flux (~1 - 107 n/cm2s) at the sample. Furthermore the instrument and the angular detector resolution is designed also for strong recrystallisation textures as well as for weak textures of polyphase rocks. These instrument characteristics allow in-situ time-resolved texture measurements during deformation experiments on rocksalt, ice and other materials as large sample environments will be implemented at POWTEX. The in-situ deformation apparatus is operated by a uniaxial spindle drive with a maximum axial load of 250 kN, which will be redesigned to minimize shadowing effects inside the cylindrical detector. The HT deformatione experiments will be carried out in uniaxial compression or extension and an upgrade to triaxial deformation conditions is envisaged. The load frame can alternatively be used for ice deformation by inserting a cryostat cell for temperatures down to 77 K with a triaxial apparatus allowing also simple shear experiments on ice. Strain rates range between 10-8 and 10-3 s-1 reaching to at least 50 % axial strain. The deformation apparatus is designed for continuous long-term deformation experiments and can be exchanged between in-situ and ex-situ placements during continuous operation inside and outside the neutron detector.

  6. 3-DIMENSIONAL Optoelectronic

    NASA Astrophysics Data System (ADS)

    Krishnamoorthy, Ashok Venketaraman

    This thesis covers the design, analysis, optimization, and implementation of optoelectronic (N,M,F) networks. (N,M,F) networks are generic space-division networks that are well suited to implementation using optoelectronic integrated circuits and free-space optical interconnects. An (N,M,F) networks consists of N input channels each having a fanout F_{rm o}, M output channels each having a fanin F_{rm i}, and Log_{rm K}(N/F) stages of K x K switches. The functionality of the fanout, switching, and fanin stages depends on the specific application. Three applications of optoelectronic (N,M,F) networks are considered. The first is an optoelectronic (N,1,1) content -addressable memory system that achieves associative recall on two-dimensional images retrieved from a parallel-access optical memory. The design and simulation of the associative memory are discussed, and an experimental emulation of a prototype system using images from a parallel-readout optical disk is presented. The system design provides superior performance to existing electronic content-addressable memory chips in terms of capacity and search rate, and uses readily available optical disk and VLSI technologies. Next, a scalable optoelectronic (N,M,F) neural network that uses free-space holographic optical interconnects is presented. The neural architecture minimizes the number of optical transmitters needed, and provides accurate electronic fanin with low signal skew, and dendritic-type fan-in processing capability in a compact layout. Optimal data-encoding methods and circuit techniques are discussed. The implementation of an prototype optoelectronic neural system, and its application to a simple recognition task is demonstrated. Finally, the design, analysis, and optimization of a (N,N,F) self-routing, packet-switched multistage interconnection network is described. The network is suitable for parallel computing and broadband switching applications. The tradeoff between optical and electronic interconnects is examined quantitatively by varying the electronic switch size K. The performance of the (N,N,F) network versus the fanning parameter F, is also analyzed. It is shown that the optoelectronic (N,N,F) networks provide a range of performance-cost alternatives, and offer superior performance-per-cost to fully electronic switching networks and to previous networks designs.

  7. First steps towards real-time radiography at the NECTAR facility

    NASA Astrophysics Data System (ADS)

    Bücherl, T.; Wagner, F. M.; v. Gostomski, Ch. Lierse

    2009-06-01

    The beam tube SR10 at Forschungsneutronenquelle Heinz Maier-Leibnitz (FRM II) provides an intense beam of fission neutrons for medical application (MEDAPP) and for radiography and tomography of technical and other objects (NECTAR). The high neutron flux of up to 9.8E+07 cm -2 s -1 (depending on filters and collimation) with a mean energy of about 1.9 MeV at the sample position at the NECTAR facility prompted an experimental feasibility study to investigate the potential for real-time (RT) radiography.

  8. The German Invasion of Yugoslavia: Insights for Crisis Action Planning and Operational Art in a Combined Environment

    DTIC Science & Technology

    1993-04-21

    Genral Rirt’ardtIs XLI Panzer Corps would head smthwest, frm the Rumnian city of Tweevar and join the attack on Belgrade. 77 Gwnral Alea r Larw took mmnd...XLVI Panzer Corps alog with the LI Infantry and X= Mountain Corps empted from their bridgeheads. The Fourth Army disnt -rate and the 14th Panzer took...Vrtovsk to make cotact with the Italians uhile he regrouped the XLIX mountain and LI Corps on the Saw river for an advarme an Sarajevo. The mays on

  9. ST-LO (7 July -19 July 1944)

    DTIC Science & Technology

    1946-08-21

    artillery, but the main troubles came in operating heavy vehicles through muddy fields, slippery trails, and hedgerows. The II9th Infantry felt...Army’s attack began, continued to balk aerial reconnaissance and to make the roads slippery and muddy. The axis of advance of the attacking task...JuLTI J ! VII - XIX CoIIps IOUNOIJIY AS OF 6 JULY .....lIT, If’ III IIIET!!!!. I o " ’" •’" .. flU ( \\ J Elm ’ "’/1’ v,",f «. ? --/ F:rm~91

  10. Humeral retroversion and shoulder rotational mobility in young handball practitioners

    PubMed Central

    Quadros, Gustavo Aguiar; Döhnert, Marcelo Baptista

    2015-01-01

    ABSTRACT OBJECTIVE : To evaluate the prevalence of humeral retroversion and rotational mobility (RHH) in young handball practitioners and non-practitioners. METHODS : This is a cross-sectional study performed with two groups: the handball group, with 14 female students practicing handball and the control group, with 13 young participants non-practicing pitch sports. RESULTS : The handball group presented full rotational movement (FRM) hi-gher than the control group in both the dominant shoulder (p=0.001) and the non-dominant shoulder (p=0.0001). The mobility of active and passive internal rotation was significantly higher in handball players in both shoulders. The handball group presented lower internal rotation range of motion for the dominant shoulder as compared to the non-dominant shoul-der (p=0.001). CONCLUSION : Young handball practitioners, des-pite skeletally immature, showed a higher MRT than the control group. The handball group showed loss of internal rotation (medial) on the dominant shoulder as compared to the non--dominant shoulder. Level of Evidence II, Prospective Study. PMID:27057141

  11. On the use of harmonized HCHO and NO2 MAXDOAS measurements for the validation of GOME-2 and OMI satellite sensors

    NASA Astrophysics Data System (ADS)

    Pinardi, Gaia; Hendrick, François; Gielen, Clio; Van Roozendael, Michel; De Smedt, Isabelle; Lambert, Jean-Christopher; Granville, José; Compernolle, Steven; Richter, Andreas; Peters, Enno; Piters, Ankie; Wagner, Thomas; Wang, Yang; Drosoglou, Theano; Bais, Alkis; Wang, Shanshan; Saiz-Lopez, Alfonso

    2017-04-01

    During the last decade, the MAXDOAS technique has been increasingly recognized as a source of Fiducial Reference Measurements (FRM) suitable for the validation of satellite nadir observations of species relevant for climate and air quality like NO2 and HCHO. As part of the EU FP7 QA4ECV (Quality Assurance for Essential Climate Variables; see http://www.qa4ecv.eu/) project, efforts have been recently made to harmonize a network of a dozen of MAXDOAS spectrometers in view of their use to assess the quality of satellite climate data records generated within the same project. Harmonization tasks have addressed both retrieval steps involved in MAXDOAS retrievals, i.e. the DOAS spectral fit providing the differential slant column densities (DSCDs) and the conversion of the retrieved DSCDs into vertical profiles and/or vertical column densities (VCDs). In this work, we illustrate the successive harmonization steps and present the resulting QA4ECV MAXDOAS database v2. The approach adopted for the conversion of slant to vertical columns is based on a simplified look-up-table approach. The strength and limitation of this approach are discussed using reference data retrieved using an optimal estimation scheme. The QA4ECV MAXDOAS database is then used to validate satellite data sets of NO2 and HCHO columns derived from the Aura/OMI and MetOp/GOME-2 sensors. The methodology of comparison, which is also a subject of the QA4ECV project, is reviewed with respect to co-location criteria, impact of vertical and horizontal smoothing and representativeness of validation sites. We conclude by assessing the current strengths and limitations of the existing MAXDOAS datasets for NO2 and HCHO satellite validation.

  12. A pilot split-scalp study of combined fractional radiofrequency microneedling and 5% topical minoxidil in treating male pattern hair loss.

    PubMed

    Yu, A-J; Luo, Y-J; Xu, X-G; Bao, L-L; Tian, T; Li, Z-X; Dong, Y-X; Li, Y-H

    2018-06-27

    Various trials have been conducted on the management of male pattern hair loss (MPHL), but the outcomes often seem to be limited. Adjuvant therapies are urgently needed. To evaluate the efficacy and safety of combined fractional radiofrequency microneedling (FRM) and 5% topical minoxidil in the treatment of male pattern hair loss. In total, 19 Chinese men were enrolled in this randomized, controlled, split-scalp trial. Participants received monotherapy with 5% topical minoxidil twice daily to one half of the scalp, while on the other half of the scalp the treatment with twice-daily 5% topical minoxidil was combined with five sessions of FRM at 4-week intervals. Mean hair count and hair thickness, global assessment by the investigators, subject self-assessment and adverse effects were assessed. After 5 months of treatment, mean hair count increased from 44.12 ± 21.58 to 73.14 ± 25.45 on the combined-therapy side and from 46.22 ± 18.77 to 63.21 ± 19.22 on the monotherapy side, while mean hair thickness increased from 53 ± 13 μm to 71 ± 15 μm and from 52 ± 16 μm to 66 ± 14 μm, respectively. Compared with the monotherapy side, the combined-therapy side had a higher degree of improvement in both hair count (P = 0.01) and hair thickness (P = 0.02). Combined treatment with fractional radiofrequency microneedle and 5% topical minoxidil could be an effective and safe treatment option for male pattern hair loss. © 2018 British Association of Dermatologists.

  13. High-flux PGAA for milligram-weight samples

    NASA Astrophysics Data System (ADS)

    Kudejova, P.; Révay, Z.; Kleszcz, K.; Genreith, C.; Rossbach, M.

    2015-05-01

    With the high-intensity cold neutron flux available at the Prompt Gamma Activation Analysis (PGAA) instrument of the research reactor FRM II at the Heinz Maier-Leibnitz Zentrum (MLZ), samples with a weight of 1 mg or even less can be investigated for their elemental compositions using the (n,γ) capture reaction. In such cases, the typical sample packing material for PGAA experiments made of 25 μm thick PTFE foil (ca. 80 mg) can be orders of magnitude more massive than the sample weight itself. Proper choice of the packing material and measuring conditions are then of the highest importance [1].

  14. Ambient and laboratory evaluation of a low-cost particulate matter sensor.

    PubMed

    Kelly, K E; Whitaker, J; Petty, A; Widmer, C; Dybwad, A; Sleeth, D; Martin, R; Butterfield, A

    2017-02-01

    Low-cost, light-scattering-based particulate matter (PM) sensors are becoming more widely available and are being increasingly deployed in ambient and indoor environments because of their low cost and ability to provide high spatial and temporal resolution PM information. Researchers have begun to evaluate some of these sensors under laboratory and environmental conditions. In this study, a low-cost, particulate matter sensor (Plantower PMS 1003/3003) used by a community air-quality network is evaluated in a controlled wind-tunnel environment and in the ambient environment during several winter-time, cold-pool events that are associated with high ambient levels of PM. In the wind-tunnel, the PMS sensor performance is compared to two research-grade, light-scattering instruments, and in the ambient tests, the sensor performance is compared to two federal equivalent (one tapered element oscillating microbalance and one beta attenuation monitor) and gravimetric federal reference methods (FEMs/FRMs) as well as one research-grade instrument (GRIMM). The PMS sensor response correlates well with research-grade instruments in the wind-tunnel tests, and its response is linear over the concentration range tested (200-850 μg/m 3 ). In the ambient tests, this PM sensor correlates better with gravimetric methods than previous studies with correlation coefficients of 0.88. However additional measurements under a variety of ambient conditions are needed. Although the PMS sensor correlated as well as the research-grade instrument to the FRM/FEMs in ambient conditions, its response varies with particle properties to a much greater degree than the research-grade instrument. In addition, the PMS sensors overestimate ambient PM concentrations and begin to exhibit a non-linear response when PM 2.5 concentrations exceed 40 μg/m 3 . These results have important implications for communicating results from low-cost sensor networks, and they highlight the importance of using an appropriate correction factor for the target environmental conditions if the user wants to compare the results to FEM/FRMs. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Development and field validation of a community-engaged particulate matter air quality monitoring network in Imperial, California, USA.

    PubMed

    Carvlin, Graeme N; Lugo, Humberto; Olmedo, Luis; Bejarano, Ester; Wilkie, Alexa; Meltzer, Dan; Wong, Michelle; King, Galatea; Northcross, Amanda; Jerrett, Michael; English, Paul B; Hammond, Donald; Seto, Edmund

    2017-12-01

    The Imperial County Community Air Monitoring Network was developed as part of a community-engaged research study to provide real-time particulate matter (PM) air quality information at a high spatial resolution in Imperial County, California. The network augmented the few existing regulatory monitors and increased monitoring near susceptible populations. Monitors were both calibrated and field validated, a key component of evaluating the quality of the data produced by the community monitoring network. This paper examines the performance of a customized version of the low-cost Dylos optical particle counter used in the community air monitors compared with both PM 2.5 and PM 10 (particulate matter with aerodynamic diameters <2.5 and <10 μm, respectively) federal equivalent method (FEM) beta-attenuation monitors (BAMs) and federal reference method (FRM) gravimetric filters at a collocation site in the study area. A conversion equation was developed that estimates particle mass concentrations from the native Dylos particle counts, taking into account relative humidity. The R 2 for converted hourly averaged Dylos mass measurements versus a PM 2.5 BAM was 0.79 and that versus a PM 10 BAM was 0.78. The performance of the conversion equation was evaluated at six other sites with collocated PM 2.5 environmental beta-attenuation monitors (EBAMs) located throughout Imperial County. The agreement of the Dylos with the EBAMs was moderate to high (R 2 = 0.35-0.81). The performance of low-cost air quality sensors in community networks is currently not well documented. This paper provides a methodology for quantifying the performance of a next-generation Dylos PM sensor used in the Imperial County Community Air Monitoring Network. This air quality network provides data at a much finer spatial and temporal resolution than has previously been possible with government monitoring efforts. Once calibrated and validated, these high-resolution data may provide more information on susceptible populations, assist in the identification of air pollution hotspots, and increase community awareness of air pollution.

  16. Reconstructing the Auditory Apparatus of Therapsids by Means of Neutron Tomography

    NASA Astrophysics Data System (ADS)

    Laaß, Michael; Schillinger, Burkhard

    The internal cranial structure of mammalian ancestors, i.e. the therapsids or ;mammal-like reptiles;, is crucial for understanding the early mammalian evolution. In the past therapsid skulls were investigated by mechanical sectioning or serial grinding, which was a very time-consuming and destructive process and could only be applied to non-valuable or poorly preserved specimens. As most therapsid skulls are embedded in terrestrial iron-rich sediments of Late Permian or Triassic age, i.e. so called ;Red beds;, a successful investigation with X-Rays is often not possible. We successfully investigated therapsid skulls by means of neutron tomography at the facility ANTARES at FRM II in Munich using cold neutron radiation. This kind of radiation is able to penetrate iron-rich substances in the range between 5 and 15 cm and produces a good contrast between matrix and bones, which enables segmentation of internal cranial structures such as bones, cavities and canals of nerves and blood vessels. In particular, neutron tomography combined with methods of 3D modeling was used here for the investigation and reconstruction of the auditory apparatus of therapsids.

  17. Effects of Standard Extremity on Mixed Standard Scale Performance Ratings.

    DTIC Science & Technology

    1983-03-01

    e C co lude’d th bt Ih e mixed standard scal, f:rm.0l porf(, r ,t l J, wul I...levels. MSSI (hE) was con, posed c.f s t ;4tri 4 .rts re f I t i nq m a x I Iy extreme scal e Sva Iues for each c .,f th: f ur diicn s iorr rI, r so...8217rte on the appraisal i nstrum n . I I (ME) w . c ,.,pos d of stat..ment(. with mcderately ext- r ,?’, e sc I e val I.... IS I I I F) was co0. o e J

  18. Evaluating Pillar Industry’s Transformation Capability: A Case Study of Two Chinese Steel-Based Cities

    PubMed Central

    Li, Zhidong; Marinova, Dora; Guo, Xiumei; Gao, Yuan

    2015-01-01

    Many steel-based cities in China were established between the 1950s and 1960s. After more than half a century of development and boom, these cities are starting to decline and industrial transformation is urgently needed. This paper focuses on evaluating the transformation capability of resource-based cities building an evaluation model. Using Text Mining and the Document Explorer technique as a way of extracting text features, the 200 most frequently used words are derived from 100 publications related to steel- and other resource-based cities. The Expert Evaluation Method (EEM) and Analytic Hierarchy Process (AHP) techniques are then applied to select 53 indicators, determine their weights and establish an index system for evaluating the transformation capability of the pillar industry of China’s steel-based cities. Using real data and expert reviews, the improved Fuzzy Relation Matrix (FRM) method is applied to two case studies in China, namely Panzhihua and Daye, and the evaluation model is developed using Fuzzy Comprehensive Evaluation (FCE). The cities’ abilities to carry out industrial transformation are evaluated with concerns expressed for the case of Daye. The findings have policy implications for the potential and required industrial transformation in the two selected cities and other resource-based towns. PMID:26422266

  19. Evaluating Pillar Industry's Transformation Capability: A Case Study of Two Chinese Steel-Based Cities.

    PubMed

    Li, Zhidong; Marinova, Dora; Guo, Xiumei; Gao, Yuan

    2015-01-01

    Many steel-based cities in China were established between the 1950s and 1960s. After more than half a century of development and boom, these cities are starting to decline and industrial transformation is urgently needed. This paper focuses on evaluating the transformation capability of resource-based cities building an evaluation model. Using Text Mining and the Document Explorer technique as a way of extracting text features, the 200 most frequently used words are derived from 100 publications related to steel- and other resource-based cities. The Expert Evaluation Method (EEM) and Analytic Hierarchy Process (AHP) techniques are then applied to select 53 indicators, determine their weights and establish an index system for evaluating the transformation capability of the pillar industry of China's steel-based cities. Using real data and expert reviews, the improved Fuzzy Relation Matrix (FRM) method is applied to two case studies in China, namely Panzhihua and Daye, and the evaluation model is developed using Fuzzy Comprehensive Evaluation (FCE). The cities' abilities to carry out industrial transformation are evaluated with concerns expressed for the case of Daye. The findings have policy implications for the potential and required industrial transformation in the two selected cities and other resource-based towns.

  20. Radio frequency elevator for a pulsed positron beam

    NASA Astrophysics Data System (ADS)

    Dickmann, Marcel; Mitteneder, Johannes; Kögel, Gottfried; Egger, Werner; Sperr, Peter; Ackermann, Ulrich; Piochacz, Christian; Dollinger, Günther

    2016-06-01

    An elevator increases the potential energy of a particle beam with respect to ground potential without any alteration of kinetic energy and other beam parameters. This elevator is necessary for the implementation of the Munich Scanning Positron Microscope (SPM) at the intense positron source NEPOMUC at the research reactor FRM II in Munich. The principles of the rf elevator for pure electrostatically guided positrons are described. Measurements of beam quality behind the elevator are reported, which confirm that after the implementation of elevator and SPM at NEPOMUC the SPM can be operated at a considerably improved resolution (~ 0.3 μm) and event rate (~3.7 kHz) compared to the laboratory based β+-source.

  1. Cost-effective wavelength-tunable fiber laser using self-seeding Fabry-Perot laser diode.

    PubMed

    Yeh, Chien-Hung; Shih, Fu Y; Wang, Chia H; Chow, Chi W; Chi, Sien

    2008-01-07

    We propose and experimentally demonstrate a continuous wave (CW) tunable-wavelength fiber laser using self-seeding Fabry-Perot laser diode (FP-LD) without optical amplifier inside gain cavity. By employing a tunable bandpass filter (TBF) and a fiber reflected mirror (FRM) within a gain cavity, the fiber laser can lase a single-longitudinal wavelength due to the self-seeding operation. The proposed tunable wavelength laser has a good performance of the output power (> -15 dBm) and optical side-mode suppression ratio (> 40 dB) in the wavelength tuning range of 1533.75 to 1560.95 nm. In addition, the output stabilities of the fiber laser are also investigated.

  2. Analysis on the similarity between steel ladles and hot-water models regarding natural convection phenomena

    NASA Astrophysics Data System (ADS)

    Liviu, Pascu; Adriana, Putan; Vasile, Putan; Alina, Lascutoni

    2012-09-01

    The similarity between steel ladles and hot water model regarding natural convection phenomena has been analyzed through examination of the numerical solutions of turbulent Navier-Stokes partial differential equations governing the phenomena in question. Key similarity criteria for non-isothermal physical modeling of steel ladles with hot-water models have been derived as Frm = Frp and (β∇T)m = (β∇T)p where the subscript m and p stand for the water model and the prototype steel ladle, respectively. Accordingly, appropriate conditions fulfilling the above criteria, such as model size, water temperature, time scale factor and the scale factor of boundary heat loss fluxes, have been proposed and discussed.

  3. Texture analysis at neutron diffractometer STRESS-SPEC

    NASA Astrophysics Data System (ADS)

    Brokmeier, H.-G.; Gan, W. M.; Randau, C.; Völler, M.; Rebelo-Kornmeier, J.; Hofmann, M.

    2011-06-01

    In response to the development of new materials and the application of materials and components in advanced technologies, non-destructive measurement methods of textures and residual stresses have gained worldwide significance in recent years. The materials science neutron diffractometer STRESS-SPEC at FRM II (Garching, Germany) is designed to be applied equally to texture and residual stress analyses by virtue of its very flexible configuration. Due to the high penetration capabilities of neutrons and the high neutron flux of STRESS-SPEC it allows a combined analysis of global texture, local texture, strain pole figure and FWHM pole figure in a wide variety of materials including metals, alloys, composites, ceramics and geological materials. Especially, the analysis of texture gradients in bulk materials using neutron diffraction has advantages over laboratory X-rays and EBSD for many scientific cases. Moreover, neutron diffraction is favourable for coarse-grained materials, where bulk information averaged over texture inhomogeneities is needed, and also stands out due to easy sample preparation. In future, the newly developed robot system for STRESS-SPEC will allow much more flexibility than an Eulerian cradle as on standard instruments. Five recent measurements are shown to demonstrate the wide range of possible texture applications at STRESS-SPEC diffractometer.

  4. POWTEX - A new High-Intensity Powder and Texture Diffractometer at FRM II, Garching Germany

    NASA Astrophysics Data System (ADS)

    Walter, J. M.; Brückel, T.; Dronskowski, R.; Hansen, B. T.; Houben, A.; Klein, H.; Leiss, B.; Vollbrecht, A.; Sowa, H.

    2009-05-01

    In recent years, neutron diffraction has become a routine tool in Geoscience for experimental high-field (HP/HT/HH) powder diffraction and for the quantitative analysis of the crystallographic preferred orientation (CPO). Quantitative texture analysis is e.g. involved in the research fields of fabric development in mono- and polyphase rocks, deformation histories and kinematics during mountain building processes and the characterization of flow kinematics in lava flows. Secondly the quantitative characterization of anisotropic physical properties of both rock and analogue materials is conducted by bulk texture measurements of sometimes larger sample volumes. This is easily achievable by neutron diffraction due to the high penetration capabilities of the neutrons. The resulting geoscientific need for increased measuring time at neutron diffraction facilities with the corresponding technical characteristics and equipment will in future be satisfied by this high-intensity diffractometer at the neutron research reactor FRM II in Garching, Germany. It will be built by a consortium of groups from the RWTH Aachen, Forschungszentrum Jülich and the University of Göttingen, who will also operate the instrument. The diffractometer will be optimized to high intensities (flux) with an equivalent sufficient resolution for polyphase rocks. Furthermore a broad range of d-values (0.5 to 15 Å) will be measurable. The uniqueness of this instrument is the geoscientific focus on different sample environments for in situ-static and deformation experiments (stress, strain and annealing/recrystallisation) and (U)HP/(U)HT experiments. A LP/LT or atmospheric-P deformation rig for in situ-deformation experiments on ice, halite or rock analogue materials is planned, to allow in situ-measurements of the texture development during deformation and annealing. Additionally a uniaxial HT/MP deformation apparatus for salt deformation experiments and an adapted Griggs- type deformation rig are also designated. Furthermore an uniaxial stress frame for in situ stress investigations is planned to conduct simultaneous measurements of stress, elastic or plastic deformation and texture. Other sample environments for geoscientific application will be HP/HT furnaces and pressure cells for powder diffraction investigations. Furthermore the diffractometer will be built in combination with a high-pressure multi anvil up to 25 GPa and 2500 K built by the University of Bayreuth at the same beam line. The detector concept allows single shot texture measurements and therefore the measurement of larger geological sample series as necessary for the investigations of complete geological structures. This concept is complementary to the geoscience neutron texture diffractometer in Dubna, Russia and the stress diffractometer STRESS-SPEC located also at the Garching research reactor. For powder diffraction the diffractometer will be complementary to the existing high-resolution powder diffractometer SPODI at the FRM-II. It will offer the possibility of short, high-intensity parametric powder diffraction measurements in dependency of temperature, electrical, magnetic and stress fields due to the higher flux at the sample. The optimization to high-intensities and therefore short measuring times will also allow time-resolved measurements of kinetic reactions even of small sample volumes.

  5. Development of a formaldehyde biosensor with application to synthetic methylotrophy.

    PubMed

    Woolston, Benjamin M; Roth, Timothy; Kohale, Ishwar; Liu, David R; Stephanopoulos, Gregory

    2018-01-01

    Formaldehyde is a prevalent environmental toxin and a key intermediate in single carbon metabolism. The ability to monitor formaldehyde concentration is, therefore, of interest for both environmental monitoring and for metabolic engineering of native and synthetic methylotrophs, but current methods suffer from low sensitivity, complex workflows, or require expensive analytical equipment. Here we develop a formaldehyde biosensor based on the FrmR repressor protein and cognate promoter of Escherichia coli. Optimization of the native repressor binding site and regulatory architecture enabled detection at levels as low as 1 µM. We then used the sensor to benchmark the in vivo activity of several NAD-dependent methanol dehydrogenase (Mdh) variants, the rate-limiting enzyme that catalyzes the first step of methanol assimilation. In order to use this biosensor to distinguish individuals in a mixed population of Mdh variants, we developed a strategy to prevent cross-talk by using glutathione as a formaldehyde sink to minimize intercellular formaldehyde diffusion. Finally, we applied this biosensor to balance expression of mdh and the formaldehyde assimilation enzymes hps and phi in an engineered E. coli strain to minimize formaldehyde build-up while also reducing the burden of heterologous expression. This biosensor offers a quick and simple method for sensitively detecting formaldehyde, and has the potential to be used as the basis for directed evolution of Mdh and dynamic formaldehyde control strategies for establishing synthetic methylotrophy. © 2017 Wiley Periodicals, Inc.

  6. Evaluation and Comparison of Methods for Measuring Ozone ...

    EPA Pesticide Factsheets

    Ambient evaluations of the various ozone and NO2 methods were conducted during field intensive studies as part of the NASA DISCOVER-AQ project conducted during July 2011 near Baltimore, MD; January – February 2013 in the San Juaquin valley, CA; September 2013 in Houston, TX; and July – August 2014 near Denver, CO. During field intensive studies, instruments were calibrated according to manufacturers’ operation manuals and in accordance with FRM requirements listed in 40 CFR 50. During the ambient evaluation campaigns, nightly automated zero and span checks were performed to monitor the validity of the calibration and control for drifts or variations in the span and/or zero response. Both the calibration gas concentrations and the nightly zero and span gas concentrations were delivered using a dynamic dilution calibration system (T700U/T701H, Teledyne API). The analyzers were housed within a temperature-controlled shelter during the sampling campaigns. A glass inlet with sampling height located approximately 5 m above ground level and a subsequent sampling manifold were shared by all instruments. Data generated by all analyzers were collected and logged using a field deployable data acquisition system (Envidas Ultimate). A summary of instruments used during DISCOVER-AQ deployment are listed in Table 1. Figure 1 shows a typical DISCOVER-AQ site (Houston 2013) where EPA (and others) instrumentation was deployed. Under the Clean Air Act, the U.S. EPA has estab

  7. Chemical mass balance (CMB) source apportionment and organic speciation of PM(2.5) in Missoula, Montana including the 2000 wildfire season

    NASA Astrophysics Data System (ADS)

    Ward, Tony J.

    A yearlong sampling program for PM2.5, Semi- Volatile Organic Compounds (SVOCs), and Volatile Organic Compounds (VOCs) was conducted in 2000/2001. The data were used in a Chemical Mass Balance (CMB) Source Apportionment Model (Version 8.0) to apportion the sources of PM2.5 in the Missoula Valley. Results showed that wood combustion contributed an average of 41% to the fine fraction throughout the year. The second largest source of PM 2.5 was diesel (19%), followed by ammonium nitrate (17%), the kraft recovery boilers from Smurfit-Stone Container (14%), other hog fuel boilers (6%), and street sand (5%). Results also showed that PM2.5 levels and contributions from sources were consistent on both sides of the Missoula Valley, but VOCs were twice as high in Missoula compared to Frenchtown. Another aspect of this program was to investigate the organic fraction of the Missoula Valley PM2.5 by evaluating a modified Federal Reference Method (FRM) PM2.5 sampler. A method comparison was also made between sampling for SVOCs using the modified PM2.5 sampler and in using a Hi-volume Polyurethane Foam (PUF) sampler. Results showed that the PM 2.5 PUF measured more of the lighter SVOCs compared to the Hi-vol PUF sampler. This is most likely the result of the higher flows through the Hi-vol PUF which ``strip'' the lighter organics from the surface of the filter. The wildland fires of summer 2000 comprised one of the most severe fire seasons is U.S. history, and had a direct impact on the city of Missoula. Sampling in Missoula was already in progress when the fires began and smoke started rolling into the Missoula Valley. Samples were collected before, during, and after the 2000 fire season, and a detailed characterization of particulate and gaseous emissions from extensive wildland fires was obtained. The 2000/2001 CMB Sampling Program data collected during the 2000 fire season suggest that the main health impacts to downwind populations reside in the fine particulate exposures, with an average of 81% of the Missoula Valley PM2.5 resulting from forest fires.

  8. Corrections on energy spectrum and scatterings for fast neutron radiography at NECTAR facility

    NASA Astrophysics Data System (ADS)

    Liu, Shu-Quan; Bücherl, Thomas; Li, Hang; Zou, Yu-Bin; Lu, Yuan-Rong; Guo, Zhi-Yu

    2013-11-01

    Distortions caused by the neutron spectrum and scattered neutrons are major problems in fast neutron radiography and should be considered for improving the image quality. This paper puts emphasis on the removal of these image distortions and deviations for fast neutron radiography performed at the NECTAR facility of the research reactor FRM- II in Technische Universität München (TUM), Germany. The NECTAR energy spectrum is analyzed and established to modify the influence caused by the neutron spectrum, and the Point Scattered Function (PScF) simulated by the Monte-Carlo program MCNPX is used to evaluate scattering effects from the object and improve image quality. Good analysis results prove the sound effects of the above two corrections.

  9. Search for the permanent electric dipole moment of 129Xe

    NASA Astrophysics Data System (ADS)

    Sachdeva, Natasha; Chupp, Timothy; Gong, Fei; Babcock, Earl; Salhi, Zahir; Burghoff, Martin; Fan, Isaac; Killian, Wolfgang; Knappe-Grüneberg, Silvia; Schabel, Allard; Seifert, Frank; Trahms, Lutz; Voigt, Jens; Degenkolb, Skyler; Fierlinger, Peter; Krägeloh, Eva; Lins, Tobias; Marino, Michael; Meinel, Jonas; Niessen, Benjamin; Stuiber, Stefan; Terrano, William; Kuchler, Florian; Singh, Jaideep

    2017-09-01

    CP-violation in Beyond-the-Standard-Model physics, necessary to explain the baryon asymmetry, gives rise to permanent electric dipole moments (EDMs). EDM measurements of the neutron, electron, paramagnetic and diamagnetic atoms constrain CP-violating parameters. The current limit for the 129Xe EDM is 6 ×10-27 e . cm (95 % CL). The HeXeEDM experiment at FRM-II (Munich Research Reactor) and BMSR-2 (Berlin Magnetically Shielded Room) uses a stable magnetic field in a magnetically shielded room and 3He comagnetometer with potential to improve the limit by two orders of magnitude. Polarized 3He and 129Xe free precession is detected with SQUID magnetometers in the presence of applied electric and magnetic fields. Conclusions from recent measurements will be presented.

  10. Intercomparison of an Aerosol Chemical Speciation Monitor (ACSM) with ambient fine aerosol measurements in Downtown Atlanta, Georgia

    NASA Astrophysics Data System (ADS)

    Budisulistiorini, S. H.; Canagaratna, M. R.; Croteau, P. L.; Baumann, K.; Edgerton, E. S.; Kollman, M. S.; Ng, N. L.; Verma, V.; Shaw, S. L.; Knipping, E. M.; Worsnop, D. R.; Jayne, J. T.; Weber, R. J.; Surratt, J. D.

    2013-12-01

    The Aerodyne Aerosol Chemical Speciation Monitor (ACSM) was recently developed to provide long-term real-time continuous measurements of ambient non-refractory (i.e., organic, sulfate, ammonium, nitrate, and chloride) submicron particulate matter (NR-PM1). Currently, there are a limited number of field studies that evaluate the long-term performance of the ACSM against established monitoring networks. In this study, we present seasonal intercomparisons of the ACSM with collocated fine aerosol (PM2.5) measurements at the Southeastern Aerosol Research and Characterization (SEARCH) Jefferson Street (JST) site near downtown Atlanta, GA, during 2011-2012. The collocated measurements included a second ACSM, continuous and integrated sulfate, nitrate, and ammonium measurements, as well as a semi-continuous Sunset organic carbon/elemental carbon (OC/EC) analyzer, continuous tapered element oscillating microbalance (TEOM), 24 h integrated Federal Reference Method (FRM) filters, and continuous scanning electrical mobility system-mixing condensation particle counter (SEMS-MCPC). Intercomparison of the two collocated ACSMs resulted in strong correlations (r2 > 0.8) for all chemical species, except chloride (r2 = 0.21); mass concentration for all chemical species agreed within ±27%, indicating that ACSM instruments are capable of stable and reproducible operation. Chemical constituents measured by the ACSM are also compared with those obtained from the continuous measurements from JST. Since the continuous measurement concentrations are adjusted to match the integrated filter measurements, these comparisons reflect the combined uncertainties of the ACSM, continuous, and filter measurements. In general, speciated ACSM mass concentrations correlate well (r2 > 0.7) with the continuous measurements from JST, although the correlation for nitrate is weaker (r2 = 0.55) in summer. Differences between ACSM mass concentrations and the filter-adjusted JST continuous data are 5-27%, 4-25%, and 34-51% for sulfate, ammonium, and nitrate, respectively. These comparisons are all close to the stated ±30% accuracy of the ACSM except for nitrate. These discrepancies could be due to positive biases in the ACSM nitrate concentrations from interferences at the NO+ (m/z 30) fragment ion and/or negative artifacts in the nitrate filter measurement (from volatilization of NH4NO3) are also possible. The organic matter OM/OC ratios derived from linear regression of ACSM OM vs. Sunset OC/EC analyzer are 4.18 ± 0.04 and 3.59 ± 0.02 for summer and fall, respectively. Linear correlations of the ACSM NR-PM1 plus EC with TEOM PM2.5 mass are strong (r2 > 0.7) with percentage difference of 19% and 80% during summer and fall, respectively. On the other hand, the ACSM NR-PM1 correlation with FRM PM1 is high (r2 > 0.8) with percentage difference of ±47% over three seasons. Correlation of ACSM NR-PM1 plus EC mass with SEMS-MCPC PM1 volume concentration results in an estimation of aerosol density of 1.61 g cm-3 for fall 2012 period. ACSM organic concentrations measured during this study were obtained using relative ionization efficiency (RIE) values observed in Aerodyne Aerosol Mass Spectrometer (AMS). Explicit calibration of the ACSM relative ionizations for ammonium, nitrate, and sulfate, during this study was shown to improve the comparisons between ACSM and collocated measurements for these species. The accuracy of the organic and total mass concentrations would likely also be improved if organic relative ionization efficiency values for the ACSM were available during this study. Laboratory calibrations of ACSM relative ionization efficiencies using organic particles of known composition are recommended for future studies.

  11. Instrument developments and recent scientific highlights at the J-NSE

    NASA Astrophysics Data System (ADS)

    Ivanova, Oxana; Pasini, Stefano; Monkenbusch, Michael; Holderer, Olaf

    2017-06-01

    The J-NSE neutron spin echo spectrometer faces now 10 years of successful user operation at the FRM II research reactor at the Heinz Maier-Leibnitz Zentrum (MLZ). We present scientific highlights and instrumental developments of the last decade, for example the development of grazing incidence neutron spin echo spectroscopy (GINSES) at the J-NSE and investigations of the dynamics at solid-liquid interfaces with this new option. Polymers in confinement have been a prominent topic, as well as the internal dynamics of proteins. The scientific questions also triggered instrumental developments such as a new polarizer and a new neutron guide concept. Finally, the future of the J-NSE will be addressed with a short presentation of the current upgrade program with superconducting main coils with reduced intrinsic field integral inhomogeneity.

  12. Comparison of MAX-DOAS profiling algorithms during CINDI-2 - Part 1: aerosols

    NASA Astrophysics Data System (ADS)

    Friess, Udo; Hendrick, Francois; Tirpitz, Jan-Lukas; Apituley, Arnoud; van Roozendael, Michel; Kreher, Karin; Richter, Andreas; Wagner, Thomas

    2017-04-01

    The second Cabauw Intercomparison campaign for Nitrogen Dioxide measuring Instruments (CINDI-2) took place at the Cabauw Experimental Site for Atmospheric Research (CESAR; Utrecht area, The Netherlands) from 25 August until 7 October 2016. CINDI-2 was aiming at assessing the consistency of MAX-DOAS slant column density measurements of tropospheric species (NO2, HCHO, O3, and O4) relevant for the validation of future ESA atmospheric Sentinel missions, through coordinated operation of a large number of DOAS and MAXDOAS instruments from all over the world. An important objective of the campaign was to study the relationship between remote-sensing column and profile measurements of the above species and collocated reference ancillary observations. For this purpose, the CINDI-2 Profiling Task Team (CPTT) was created, involving 22 groups performing aerosol and trace gas vertical profile inversion using dedicated MAX-DOAS profiling algorithms, as well as the teams responsible for ancillary profile and surface concentration measurements (NO2 analysers, NO2 sondes, NO2 and Raman LIDARs, CAPS, Long-Path DOAS, sun photometer, nephelometer, etc). The main purpose of the CPTT is to assess the consistency of the different profiling tools for retrieving aerosol extinction and trace gas vertical profiles through comparison exercises using commonly defined settings and to validate the retrievals with correlative observations. In this presentation, we give an overview of the MAX-DOAS vertical profile comparison results, focusing on the retrieval of aerosol extinction profiles, with the trace gas retrievals being presented in a companion abstract led by F. Hendrick. The performance of the different algorithms is investigated with respect to the variable visibility and cloud conditions encountered during the campaign. The consistency between optimal-estimation-based and parameterized profiling tools is also evaluated for these different conditions, together with the level of agreement with available ancillary aerosol observations, including sun photometer, nephelometer and LIDAR. This comparison study will be put in the perspective of the development of a centralized MAX-DOAS processing system within the framework of the ESA Fiducial Reference Measurements (FRM) project.

  13. Comparison of MAX-DOAS profiling algorithms during CINDI-2 - Part 2: trace gases

    NASA Astrophysics Data System (ADS)

    Hendrick, Francois; Friess, Udo; Tirpitz, Lukas; Apituley, Arnoud; Van Roozendael, Michel; Kreher, Karin; Richter, Andreas; Wagner, Thomas

    2017-04-01

    The second Cabauw Intercomparison campaign for Nitrogen Dioxide measuring Instruments (CINDI-2) took place at the Cabauw Experimental Site for Atmospheric Research (CESAR; Utrecht area, The Netherlands) from 25 August until 7 October 2016. CINDI-2 was aiming at assessing the consistency of MAX-DOAS slant column density measurements of tropospheric species (NO2, HCHO, O3, and O4) relevant for the validation of future ESA atmospheric Sentinel missions, through coordinated operation of a large number of DOAS and MAXDOAS instruments from all over the world. An important objective of the campaign was to study the relationship between remote-sensing column and profile measurements of the above species and collocated reference ancillary observations. For this purpose, the CINDI-2 Profiling Task Team (CPTT) was created, involving 22 groups performing aerosol and trace gas vertical profile inversion using dedicated MAX-DOAS profiling algorithms, as well as the teams responsible for ancillary profile and surface concentration measurements (NO2 analysers, NO2 sondes, NO2 and Raman LIDARs, CAPS, Long-Path DOAS, sunphotometer, nephelometer, etc). The main purpose of the CPTT is to assess the consistency of the different profiling tools for retrieving aerosol extinction and trace gas vertical profiles through comparison exercises using commonly defined settings and to validate the retrievals with correlative observations. In this presentation, we give an overview of the MAX-DOAS vertical profile comparison results, focusing on NO2 and HCHO, the aerosol retrievals being presented in a companion abstract led by U. Frieß. The performance of the different algorithms is investigated with respect to the various sky and weather conditions and aerosol loadings encountered during the campaign. The consistency between optimal-estimation-based and parameterized profiling tools is also evaluated for these different conditions, together with the level of agreement with available NO2 and HCHO ancillary observations. This comparison study will be put in the perspective of the development of a centralized MAX-DOAS processing system within the framework of the ESA Fiducial Reference Measurements (FRM) project.

  14. Measurement of the cross-section of high transverse momentum vector bosons reconstructed as single jets and studies of jet substructure in pp collisions at √s = 7 TeV with the ATLAS detector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aad, G.

    2014-11-04

    This article presents a measurement of the cross-section for high transverse momentum W and Z bosons produced in pp collisions and decaying to all-hadronic final states. The data used in the analysis were recorded by the ATLAS detector at the CERN Large Hadron Collider at a centre-of-mass energy ofmore » $$\\sqrt{s}=7\\;{\\rm Te}{\\rm V}$$ and correspond to an integrated luminosity of $$4.6\\;{\\rm f}{{{\\rm b}}^{-1}}$$. The measurement is performed by reconstructing the boosted W or Z bosons in single jets. The reconstructed jet mass is used to identify the W and Z bosons, and a jet substructure method based on energy cluster information in the jet centre-of-mass frame is used to suppress the large multi-jet background. The cross-section for events with a hadronically decaying W or Z boson, with transverse momentum $${{p}_{{\\rm T}}}\\gt 320\\;{\\rm Ge}{\\rm V}$$ and pseudorapidity $$|\\eta |\\lt 1.9$$, is measured to be $${{\\sigma }_{W+Z}}=8.5\\pm 1.7$$ pb and is compared to next-to-leading-order calculations. The selected events are further used to study jet grooming techniques.« less

  15. PubMed

    De Battista, Juan Carlos; Buonanotte, Carlos Federico; Foa Torres, Gustavo A; Keller, Jeffrey Thomas; Aranega, Cesar I

    2018-04-24

    Antecedentes: Las enfermedades que afectan la órbita representan un desafío quirúrgico, en particular las que comprometen el ápex orbitario. Una vía óptima de acceso quirúrgico proporciona la mejor exposición permitiendo identificar ciertas estructuras anatómicas claves llamadas reparos anatómicos. Objetivo: Describir la anatomía endoscópica de la unidad estructural Fisura Orbitaria Inferior / Músculo de Müller a nivel del ápex orbitario generando así un nuevo reparo anatómico endoscópico. Material y método: Análisis descriptivo óseo de la fisura orbitaria inferior (FOI) en cráneos secos, disección y estudio bajo técnica endoscópica de 6 cabezas fijadas en formol y coloreadas; finalmente se tomaron distancias y ángulos a forámenes relacionados con el ápex orbitario a 10 cráneos secos. El análisis estadístico se realizó con el programa estadístico SPSS 17,0 (SPSS, Inc., Chicago, IL). Resultado: En todas las disecciones endoscópicas se pudo identificar la unidad fisura orbitaria inferior-músculo de Müller y también verificar su íntima relación con el ápex orbitario. Morfométricamente el foramen óptico y el foramen redondo mayor están a una distancia promedio de 65.19mm y 60.16mm respectivamente. Los ángulos promedio del FO fue de 13.32 grados y del FRM de19.31 grados. Hallamos correlación significativa entre CO. y el FRM sólo en el hemicráneo izquierdo, (Tau b de Kendall 0.69, P=0.006). No se encontraron diferencias anatómicas (o morfológicas) significativas entre lados. Conclusión: bajo técnica endoscópica la unidad Fisura Orbitaria Inferior-Músculo de Müller (FOI-MM) es un reparo anatómico constante, útil y seguro que permite el reconocimiento del ápex orbitario y sus áreas contiguas.

  16. Application of high-performance anion-exchange chromatography-pulsed amperometric detection for measuring carbohydrates in routine daily filter samples collected by a national network: 2. Examination of sugar alcohols/polyols, sugars, and anhydrosugars in the upper Midwest

    NASA Astrophysics Data System (ADS)

    Sullivan, A. P.; Frank, N.; Kenski, D. M.; Collett, J. L., Jr.

    2011-04-01

    Carbohydrate measurements of ambient samples can provide insights into the biogenic fraction of the organic carbon (OC) aerosol. However, lack of measurement on a routine basis limits data analysis. In a companion paper, 1 year of archived 1-in-6 day FRM (Federal Reference Monitor) filter samples from the PM2.5 NAAQS compliance monitoring network collected at 10 sites in the upper Midwest were analyzed using high-performance anion-exchange chromatography with pulsed amperometric detection to determine the regional impact of biomass burning. Along with levoglucosan, 13 other carbohydrates were simultaneously measured, including two more anhydrosugars (mannosan and galactosan), five sugars (arabinose, galactose, glucose, mannose, xylose), and six sugar alcohols/polyols (glycerol, methyltetrols, threitol/erythritol, xylitol, sorbitol, mannitol). This paper focuses on the results from these carbohydrates in order to investigate their sources and trends both spatially and temporally. Mannosan, galactosan, arabinose, xylose, and threitol/erythritol all correlated with levoglucosan (R2 from 0.43 to 0.97), suggesting biomass burning as their main source. Glucose and mannitol exhibited higher concentrations in summer and at more southern sites, likely due to vegetation differences at the sites. Using mannitol, the contribution of spores to OC was found to be <1%. Methyltetrols were highly correlated with water-soluble OC (R2 from 0.63 to 0.95) and in higher concentrations at more eastern sites. This spatial pattern is possibly due to these sites being downwind of the high isoprene emission zones that occur in the western part of the Midwest from oak forests in the Ozarks and spruce forests in the northern lake states.

  17. A network of autism linked genes stabilizes two pools of synaptic GABAA receptors

    PubMed Central

    Tong, Xia-Jing; Hu, Zhitao; Liu, Yu; Anderson, Dorian; Kaplan, Joshua M

    2015-01-01

    Changing receptor abundance at synapses is an important mechanism for regulating synaptic strength. Synapses contain two pools of receptors, immobilized and diffusing receptors, both of which are confined to post-synaptic elements. Here we show that immobile and diffusing GABAA receptors are stabilized by distinct synaptic scaffolds at C. elegans neuromuscular junctions. Immobilized GABAA receptors are stabilized by binding to FRM-3/EPB4.1 and LIN-2A/CASK. Diffusing GABAA receptors are stabilized by the synaptic adhesion molecules Neurexin and Neuroligin. Inhibitory post-synaptic currents are eliminated in double mutants lacking both scaffolds. Neurexin, Neuroligin, and CASK mutations are all linked to Autism Spectrum Disorders (ASD). Our results suggest that these mutations may directly alter inhibitory transmission, which could contribute to the developmental and cognitive deficits observed in ASD. DOI: http://dx.doi.org/10.7554/eLife.09648.001 PMID:26575289

  18. Reusable shielding material for neutron- and gamma-radiation

    NASA Astrophysics Data System (ADS)

    Calzada, Elbio; Grünauer, Florian; Schillinger, Burkhard; Türck, Harald

    2011-09-01

    At neutron research facilities all around the world radiation shieldings are applied to reduce the background of neutron and gamma radiation as far as possible in order to perform high quality measurements and to fulfill the radiation protection requirements. The current approach with cement-based compounds has a number of shortcomings: "Heavy concrete" contains a high amount of elements, which are not desired to obtain a high attenuation of neutron and/or gamma radiation (e.g. calcium, carbon, oxygen, silicon and aluminum). A shielding material with a high density of desired nuclei such as iron, hydrogen and boron was developed for the redesign of the neutron radiography facility ANTARES at beam tube 4 (located at a cold neutron source) of FRM-II. The composition of the material was optimized by help of the Monte Carlo code MCNP5. With this shielding material a considerable higher attenuation of background radiation can be obtained compared to usual heavy concretes.

  19. A novel fiber optic geophone with high sensitivity for geo-acoustic detection

    NASA Astrophysics Data System (ADS)

    Zhang, Zhenhui; Yang, Huayong; Xiong, Shuidong; Luo, Hong; Cao, Chunyan; Ma, Shuqing

    2014-12-01

    A novel interferometric fiber optic geophone is introduced in this paper. This geophone is mainly used for geo-acoustic signal detection. The geophone use one of the three orthogonal components of mandrel type push-pull structure in mechanically and single-mode fiber optic Michelson interferometer structure with Faraday Rotation Mirror (FRM) elements in optically. The resonance frequency of the geophone is larger than 1000Hz. The acceleration sensitivity is as high as 56.6 dB (0dB re 1rad/g) with a slight sensitivity fluctuation of +/-0. 2dB within the frequency band from 20Hz to 200Hz. The geo-acoustic signals generated by underwater blasting are detected successfully. All the channels show good uniformity in the detected wave shape and the amplitudes exhibit very slight differences. The geo-acoustic signal excitated by the engine of surface vehicles was also detected successfully.

  20. Flood Resilient Systems and their Application for Flood Resilient Planning

    NASA Astrophysics Data System (ADS)

    Manojlovic, N.; Gabalda, V.; Antanaskovic, D.; Gershovich, I.; Pasche, E.

    2012-04-01

    Following the paradigm shift in flood management from traditional to more integrated approaches, and considering the uncertainties of future development due to drivers such as climate change, one of the main emerging tasks of flood managers becomes the development of (flood) resilient cities. It can be achieved by application of non-structural - flood resilience measures, summarised in the 4As: assistance, alleviation, awareness and avoidance (FIAC, 2007). As a part of this strategy, the key aspect of development of resilient cities - resilient built environment can be reached by efficient application of Flood Resilience Technology (FReT) and its meaningful combination into flood resilient systems (FRS). FRS are given as [an interconnecting network of FReT which facilitates resilience (including both restorative and adaptive capacity) to flooding, addressing physical and social systems and considering different flood typologies] (SMARTeST, http://www.floodresilience.eu/). Applying the system approach (e.g. Zevenbergen, 2008), FRS can be developed at different scales from the building to the city level. Still, a matter of research is a method to define and systematise different FRS crossing those scales. Further, the decision on which resilient system is to be applied for the given conditions and given scale is a complex task, calling for utilisation of decision support tools. This process of decision-making should follow the steps of flood risk assessment (1) and development of a flood resilience plan (2) (Manojlovic et al, 2009). The key problem in (2) is how to match the input parameters that describe physical&social system and flood typology to the appropriate flood resilient system. Additionally, an open issue is how to integrate the advances in FReT and findings on its efficiency into decision support tools. This paper presents a way to define, systematise and make decisions on FRS at different scales of an urban system developed within the 7th FP Project SMARTeST. A web based three tier advisory system FLORETO-KALYPSO (http://floreto.wb.tu-harburg.de/, Manojlovic et al, 2009) devoted to support decision-making process at the building level has been further developed to support multi-scale decision making on resilient systems, improving the existing data mining algorithms of the Business Logic tier. Further tuning of the algorithms is to be performed based on the new developments and findings in applicability and efficiency of different FRe Technology for different flood typologies. The first results obtained at the case studies in Greater Hamburg, Germany indicate the potential of this approach to contribute to the multiscale resilient planning on the road to flood resilient cities. FIAC (2007): "Final report form the Awareness and Assistance Sub-committee", FIAC, Scottish Government Zevenbergen C. et al (2008) "Challenges in urban flood management: travelling across spatial and temporal scales", Journal of FRM Volume 1 Issue 2, p 81-88 Manojlovic N., et al (2009): "Capacity Building in FRM through a DSS Utilising Data Mining Approach", Proceed. 8th HIC, Concepcion, Chile, January, 2009

  1. The Brooklyn traffic real-time ambient pollutant penetration and environmental dispersion (B-TRAPPED) field study methodology.

    PubMed

    Richmond-Bryant, Jennifer; Hahn, Intaek; Fortune, Christopher R; Rodes, Charles E; Portzer, Jeffrey W; Lee, Sangdon; Wiener, Russell W; Smith, Luther A; Wheeler, Michael; Seagraves, Jeremy; Stein, Mark; Eisner, Alfred D; Brixey, Laurie A; Drake-Richman, Zora E; Brouwer, Lydia H; Ellenson, William D; Baldauf, Richard

    2009-12-01

    The Brooklyn Traffic Real-Time Ambient Pollutant Penetration and Environmental Dispersion (B-TRAPPED) field study examined indoor and outdoor exposure to traffic-generated air pollution by studying the individual processes of generation of traffic emissions, transport and dispersion of air contaminants along a roadway, and infiltration of the contaminants into a residence. Real-time instrumentation was used to obtain highly resolved time-series concentration profiles for a number of air pollutants. The B-TRAPPED field study was conducted in the residential Sunset Park neighborhood of Brooklyn, NY, USA, in May 2005. The neighborhood contained the Gowanus Expressway (Interstate 278), a major arterial road (4(th) Avenue), and residential side streets running perpendicular to the Gowanus Expressway and 4(th) Avenue. Synchronized measurements were obtained inside a test house, just outside the test house façade, and along the urban residential street canyon on which the house was located. A trailer containing Federal Reference Method (FRM) and real-time monitors was located next to the Gowanus Expressway to assess the source. Ultrafine particulate matter (PM), PM(2.5), nitrogen oxides (NO(x)), sulfur dioxide (SO(2)), carbon monoxide (CO), carbon dioxide (CO(2)), temperature, relative humidity, and wind speed and direction were monitored. Different sampling schemes were devised to focus on dispersion along the street canyon or infiltration into the test house. Results were obtained for ultrafine PM, PM(2.5), criteria gases, and wind conditions from sampling schemes focused on street canyon dispersion and infiltration. For comparison, the ultrafine PM and PM(2.5) results were compared with an existing data set from the Los Angeles area, and the criteria gas data were compared with measurements from a Vancouver epidemiologic study. Measured ultrafine PM and PM(2.5) concentration levels along the residential urban street canyon and at the test house façade in Sunset Park were demonstrated to be comparable to traffic levels at an arterial road and slightly higher than those in a residential area of Los Angeles. Indoor ultrafine PM levels were roughly 3-10 times lower than outdoor levels, depending on the monitor location. CO, NO(2), and SO(2) levels were shown to be similar to values that produced increased risk of chronic obstructive pulmonary disease hospitalizations in the Vancouver studies.

  2. Measuring the Spin Correlation of Nuclear Muon Capture in HELIUM-3.

    NASA Astrophysics Data System (ADS)

    McCracken, Dorothy Jill

    1996-06-01

    We have completed the first measurement of the spin correlation of nuclear muon capture in ^3 He: mu^- + ^3He to nu _{mu} + ^3 H. From this spin correlation, we can extract the induced pseudoscalar form factor, F_{ rm p}, of the weak charged nuclear current. This form factor is not well known experimentally. If nuclear muon capture were a purely leptonic weak interaction, the current would have no pseudoscalar coupling, and therefore F_{rm p} arises from QCD contributions. Since ^3He is a fairly well understood system, a precise measurement of F_{rm p} could provide a direct test of the theories which describe QCD at low energies. This experiment was performed at TRIUMF in Vancouver, BC, using a muon beam. We stopped unpolarized muons in a laser polarized target filled with ^3 He and Rb vapor. The muons were captured into atomic orbitals, forming muonic ^3He which was then polarized via collisions with the optically pumped Rb vapor. When polarized muons undergo nuclear capture in ^3He, the total capture rate is proportional to (1 + {rm A_ {v}P_{v}cos} theta) where theta is the angle between the muon polarization and the triton recoil direction, P_{rm v} is the muon vector polarization and A_ {rm v} is the vector analyzing power. The partially conserved axial current hypothesis (PCAC) predicts that A_{rm v} = 0.524 +/- 0.006 Our measurement of A_{rm v} is in agreement with this prediction: A_{rm v } = 0.604 +/- 0.093 (stat.) _sp{-.142}{+.112}(syst.). This thesis will describe the design, construction, and operation of the device which simultaneously served as a polarized target and a gridded ion chamber. The ion chamber apparatus enabled us to identify recoil tritons as well as determine their direction of motion. The directional information was obtained by fitting the shapes of the pulses generated by the tritons. In addition, this thesis will describe in detail the analysis of these pulses which resulted in a measurement of the raw forward/backward asymmetry of the triton recoil direction. This asymmetry was measured to a precision of 11.5%. With the techniques employed in this experiment, a clear path exists to obtaining a precise measurement of the induced pseudoscalar coupling of the charged weak nuclear current. Plans for a future run, in which we will improve upon these techniques, are underway.

  3. Convergence at the faces of development workings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Borisenko, A.A.

    1977-07-01

    Since 1963 we have been carrying out investigations in pits of the Pechora coalfield to establish the general laws of roof-floor convergence in the face areas of development workings and their role in gas bursts. We also considered how various methods of working on the seam influence the amount of type of convergence. The observations were made in 20 workings in five pits of Vorkutaugol Group, cut by cutter-loaders and by drilling and blasting at depths between 350 and 600 m; the cross-sectional areas of the workings ranged frm 3.7 to 12.0 m/sup 2/. The aggregated data on daily convergencemore » values was analyzed by the multiple correlation method with the aid of a computer. The aim of the analysis was to elucidate the influence of six factors on the daily convergence values: the depth below the surface, the corrected seam strength, the cross-sectional area of the working, the initial distance from the face to the measurement prop, the daily advance, and the thickness of the seam. The combined correlation coefficient was rather low - 0.49 with a reliability of 9.13. The greatest influence on the convergence values is exerted by the cross-sectional area and by the distance from the face (the partial correlation coefficients being 0.281 and 0.310, respectively), and lesser influences are exerted by the depth below the surface and by the corrected strength of the seam (partial correlationcoefficients 0.164 and 0.178); the influences of seam thickness and daily face advance are very slight. The multiple correlation results indicate that a very great influence is exerted by disregarded factors, among which the most important are undoubtedly the properties of the surrounding rocks.« less

  4. NECTAR—A fission neutron radiography and tomography facility

    NASA Astrophysics Data System (ADS)

    Bücherl, T.; Lierse von Gostomski, Ch.; Breitkreutz, H.; Jungwirth, M.; Wagner, F. M.

    2011-09-01

    NECTAR (Neutron Computerized Tomography and Radiography) is a versatile facility for radiographic and tomographic investigations as well as for neutron activation experiments using fission neutrons. The radiation sources for this facility are two plates of highly enriched uranium situated in the moderator vessel in FRM II. Thermal neutrons originating from the main fuel element of the reactor generate in these plates fast neutrons. These can escape through a horizontal beam tube without moderation. The beam can be filtered and manipulated in order to reduce the accompanying gamma radiation and to match the specific experimental tasks. A summary of the main parameters required for experimental set-up and (quantitative) data evaluation is presented. The (measured) spectra of the neutron and gamma radiations are shown along with the effect of different filters on their behavior. The neutron and gamma fluxes, dose rates, L/ D-ratios, etc. and the main parameters of the actually used detection systems for neutron imaging are given, too.

  5. Scientific Verification of Faraday Rotation Modulators: Detection of Diffuse Polarized Galactic Emission

    NASA Technical Reports Server (NTRS)

    Moyerman, S.; Bierman, E.; Ade, P. A. R.; Aiken, R.; Barkats, D.; Bischoff, C.; Bock, J. J.; Chiang, H. C.; Dowell, C. D.; Duband, L.; hide

    2012-01-01

    The design and performance of a wide bandwidth linear polarization-modulator based on the Faraday effect is described. Faraday Rotation Modulators (FRMs) are solid-state polarization switches that are capable of modulation up to approx 10 kHz. Six FRMs were utilized during the 2006 observing season in the Background Imaging of Cosmic Extragalactic Polarization (BICEP) experiment; three FRMs were used at each of BICEP fs 100 and 150 GHz frequency bands. The technology was verified through high signal-to-noise detection of Galactic polarization using two of the six FRMs during four observing runs in 2006. The features exhibit strong agreement with BICEP fs measurements of the Galaxy using non-FRM pixels and with the Galactic polarization models. This marks the first detection of high signal-to-noise mm-wave celestial polarization using fast, active optical modulation. The performance of the FRMs during periods when they were not modulated was also analyzed and compared to results from BICEP fs 43 pixels without FRMs.

  6. Humeral retroversion and shoulder rotational mobility in young handball practitioners.

    PubMed

    Quadros, Gustavo Aguiar; Döhnert, Marcelo Baptista

    2015-01-01

    : To evaluate the prevalence of humeral retroversion and rotational mobility (RHH) in young handball practitioners and non-practitioners. : This is a cross-sectional study performed with two groups: the handball group, with 14 female students practicing handball and the control group, with 13 young participants non-practicing pitch sports. : The handball group presented full rotational movement (FRM) hi-gher than the control group in both the dominant shoulder (p=0.001) and the non-dominant shoulder (p=0.0001). The mobility of active and passive internal rotation was significantly higher in handball players in both shoulders. The handball group presented lower internal rotation range of motion for the dominant shoulder as compared to the non-dominant shoul-der (p=0.001). : Young handball practitioners, des-pite skeletally immature, showed a higher MRT than the control group. The handball group showed loss of internal rotation (medial) on the dominant shoulder as compared to the non--dominant shoulder. Level of Evidence II, Prospective Study.

  7. Surface investigation of Si(1 0 0), Cu, Cu on Si(1 0 0), and Au on Cu with positron annihilation induced Auger-electron spectroscopy

    NASA Astrophysics Data System (ADS)

    Hugenschmidt, C.; Mayer, J.; Schreckenbach, K.

    2007-06-01

    The surfaces of polycrystalline Cu, Au-coated Cu, Si(1 0 0) and of Si(1 0 0) coated with 1.5 monolayer Cu were investigated with positron annihilation induced Auger-electron spectroscopy (PAES). Since the electron background has been reduced considerably we observed the Cu M 2,3VV-Auger transition on a copper surface within only three hours which is the shortest acquisition time reported so far for PAES. In order to demonstrate PAES' high potential the Auger-yield, the signal-to-background ratio as well as the surface selectivity were compared with accompanying EAES-measurements quantitatively. A more efficient electron energy analyzer for the present PAES setup would lead to an additional efficiency gain of more than two orders of magnitude. The presented measurements were performed at the low-energy positron beam of high intensity NEPOMUC at the research reactor FRM II.

  8. Surface and bulk investigations at the high intensity positron beam facility NEPOMUC

    NASA Astrophysics Data System (ADS)

    Hugenschmidt, C.; Dollinger, G.; Egger, W.; Kögel, G.; Löwe, B.; Mayer, J.; Pikart, P.; Piochacz, C.; Repper, R.; Schreckenbach, K.; Sperr, P.; Stadlbauer, M.

    2008-10-01

    The NEutron-induced POsitron source MUniCh (NEPOMUC) at the research reactor FRM II delivers a low-energy positron beam ( E = 15-1000 eV) of high intensity in the range between 4 × 10 7 and 5 × 10 8 moderated positrons per second. At present four experimental facilities are in operation at NEPOMUC: a coincident Doppler-broadening spectrometer (CDBS) for defect spectroscopy and investigations of the chemical vicinity of defects, a positron annihilation-induced Auger-electron spectrometer (PAES) for surface studies and an apparatus for the production of the negatively charged positronium ion Ps -. Recently, the pulsed low-energy positron system (PLEPS) has been connected to the NEPOMUC beam line, and first positron lifetime spectra were recorded within short measurement times. A positron remoderation unit which is operated with a tungsten single crystal in back reflection geometry has been implemented in order to improve the beam brilliance. An overview of NEPOMUC's status, experimental results and recent developments at the running spectrometers are presented.

  9. In-Situ Neutron Diffraction Studies of Micromechanical Behavior in a Friction Stir Welded AA7475-T761

    NASA Astrophysics Data System (ADS)

    Liu, X. P.; Lin Peng, R.; Hofmann, M.; Johansson, S.; Wang, Y. D.

    2011-01-01

    An in-situ neutron diffraction technique was used to investigate the lattice strain distributions and micromechanical behavior in a friction stir welded (FSW) sheet of AA7475-T761. The neutron diffraction experiments were performed on the spectrometer for material research, STRESS-SPEC, at FRM II (Garching, Germany). The lattice strain profiles around the weld center were measured as a function of the applied strain during the tensile loading and unloading. The anisotropic elastic and plastic properties of the FSW aluminum alloy were simulated by elasto-plastic self-consistent (EPSC) model to predict the anisotropic deformation behaviors involving the grain-to-grain interactions. Material parameters used for describing the constitutive laws of each test position were determined from the measured lattice strain distributions for different diffraction hkl planes as well as the macroscopic stress-strain curve of the FSW aluminum alloy. A good agreement between experimental results and numerical simulations was obtained. The present investigations provided a reliable prediction of the anisotropic micromechanical behavior of the FSW aluminum alloy during tensile deformation.

  10. Paving the Road for Modern Particle Therapy - What Can We Learn from the Experience Gained with Fast Neutron Therapy in Munich?

    PubMed

    Specht, Hanno M; Neff, Teresa; Reuschel, Waltraud; Wagner, Franz M; Kampfer, Severin; Wilkens, Jan J; Petry, Winfried; Combs, Stephanie E

    2015-01-01

    While neutron therapy was a highly topical subject in the 70s and 80s, today there are only a few remaining facilities offering fast neutron therapy (FNT). Nevertheless, up to today more than 30,000 patients were treated with neutron therapy. For some indications like salivary gland tumors and malignant melanoma, there is clinical evidence that the addition of FNT leads to superior local control compared to photon treatment alone. FNT was available in Munich from 1985 until 2000 at the Reactor Neutron Therapy (RENT) facility. Patient treatment continued at the new research reactor FRM II in 2007 under improved treatment conditions, and today it can still be offered to selected patients as an individual treatment option. As there is a growing interest in high-linear energy transfer (LET) therapy with new hadron therapy centers emerging around the globe, the clinical data generated by neutron therapy might help to develop biologically driven treatment planning algorithms. Also FNT might experience its resurgence as a combinational partner of modern immunotherapies.

  11. Paving the Road for Modern Particle Therapy – What Can We Learn from the Experience Gained with Fast Neutron Therapy in Munich?

    PubMed Central

    Specht, Hanno M.; Neff, Teresa; Reuschel, Waltraud; Wagner, Franz M.; Kampfer, Severin; Wilkens, Jan J.; Petry, Winfried; Combs, Stephanie E.

    2015-01-01

    While neutron therapy was a highly topical subject in the 70s and 80s, today there are only a few remaining facilities offering fast neutron therapy (FNT). Nevertheless, up to today more than 30,000 patients were treated with neutron therapy. For some indications like salivary gland tumors and malignant melanoma, there is clinical evidence that the addition of FNT leads to superior local control compared to photon treatment alone. FNT was available in Munich from 1985 until 2000 at the Reactor Neutron Therapy (RENT) facility. Patient treatment continued at the new research reactor FRM II in 2007 under improved treatment conditions, and today it can still be offered to selected patients as an individual treatment option. As there is a growing interest in high-linear energy transfer (LET) therapy with new hadron therapy centers emerging around the globe, the clinical data generated by neutron therapy might help to develop biologically driven treatment planning algorithms. Also FNT might experience its resurgence as a combinational partner of modern immunotherapies. PMID:26640777

  12. Neutron Radiography, Tomography, and Diffraction of Commercial Lithium-ion Polymer Batteries

    NASA Astrophysics Data System (ADS)

    Butler, Leslie G.; Lehmann, Eberhard H.; Schillinger, Burkhard

    Imaging an intact, commercial battery as it cycles and wears is proved possible with neutron imaging. The wavelength range of imaging neutrons corresponds nicely with crystallographic dimensions of the electrochemically active species and the metal elec- trodes are relatively transparent. The time scale of charge/discharge cycling is well matched to dynamic tomography as performed with a golden ratio based projection angle ordering. The hydrogen content does create scatter which tends to blur internal struc- ture. In this report, three neutron experiments will be described: 3D images of charged and discharged batteries were obtained with monochromatic neutrons at the FRM II reactor. 2D images (PSI) of fresh and worn batteries as a function of charge state may show a new wear pattern. In situ neutron diffraction (SNS) of the intact battery provides more information about the concentrations of electrochemical species within the battery as a function of charge state and wear. The combination of 2D imaging, 3D imaging, and diffraction data show how neutron imaging can contribute to battery development and wear monitoring.

  13. Development of a NRSE Spectrometer with the Help of McStas - Application to the Design of Present and Future Instruments

    NASA Astrophysics Data System (ADS)

    Kredler, L.; Häußler, W.; Martin, N.; Böni, P.

    The flux is still a major limiting factor in neutron research. For instruments being supplied by cold neutrons using neutron guides, both at present steady-state and at new spallation neutron sources, it is therefore important to optimize the instrumental setup and the neutron guidance. Optimization of neutron guide geometry and of the instrument itself can be performed by numerical ray-tracing simulations using existing open-access codes. In this paper, we discuss how such Monte Carlo simulations have been employed in order to plan improvements of the Neutron Resonant Spin Echo spectrometer RESEDA (FRM II, Germany) as well as the neutron guides before and within the instrument. The essential components have been represented with the help of the McStas ray-tracing package. The expected intensity has been tested by means of several virtual detectors, implemented in the simulation code. Comparison between simulations and preliminary measurements results shows good agreement and demonstrates the reliability of the numerical approach. These results will be taken into account in the planning of new components installed in the guide system.

  14. Measurement of the ROT effect in the neutron induced fission of 235U in the 0.3 eV resonance at a hot source of polarized neutrons

    NASA Astrophysics Data System (ADS)

    Kopatch, Yuri; Novitsky, Vadim; Ahmadov, Gadir; Gagarsky, Alexei; Berikov, Daniyar; Danilyan, Gevorg; Hutanu, Vladimir; Klenke, Jens; Masalovich, Sergey

    2018-03-01

    The TRI and ROT asymmetries in fission of heavy nuclei have been extensively studied during more than a decade. The effects were first discovered in the ternary fission in a series of experiments performed at the ILL reactor (Grenoble) by a collaboration of Russian and European institutes, and were carefully measured for a number of fissioning nuclei. Later on, the ROT effect has been observed in the emission of prompt gamma rays and neutrons in fission of 235U and 233U, although its value was an order of magnitude smaller than in the α-particle emission from ternary fission. All experiments performed so far are done with cold polarized neutrons, what assumes a mixture of several spin states, the weights of these states being not well known. The present paper describes the first attempt to get "clean" data by performing the measurement of gamma and neutron asymmetries in an isolated resonance of 235U at the POLI instrument of the FRM2 reactor in Garching.

  15. The Upgrade of the Neutron Induced Positron Source NEPOMUC

    NASA Astrophysics Data System (ADS)

    Hugenschmidt, C.; Ceeh, H.; Gigl, T.; Lippert, F.; Piochacz, C.; Pikart, P.; Reiner, M.; Weber, J.; Zimnik, S.

    2013-06-01

    In summer 2012, the new NEutron induced POsitron Source MUniCh (NEPOMUC) was installed and put into operation at the research reactor FRM II. At NEPOMUC upgrade 80% 113Cd enriched Cd is used as neutron-gamma converter in order to ensure an operation time of 25 years. A structure of Pt foils inside the beam tube generates positrons by pair production. Moderated positrons leaving the Pt front foil are electrically extracted and magnetically guided to the outside of the reactor pool. The whole design, including Pt-foils, the electric lenses and the magnetic fields, has been improved in order to enhance both the intensity and the brightness of the positron beam. After adjusting the potentials and the magnetic guide and compensation fields an intensity of about 3·109 moderated positrons per second is expected. During the first start-up, the measured temperatures of about 90°C ensure a reliable operation of the positron source. Within this contribution the features and the status of NEPOMUC upgrade are elucidated. In addition, an overview of recent positron beam experiments and current developments at the spectrometers is given.

  16. Measurement of fine particulate matter water-soluble inorganic species and precursor gases in the Alberta Oil Sands Region using an improved semicontinuous monitor.

    PubMed

    Hsu, Yu-Mei; Clair, Thomas A

    2015-04-01

    The ambient ion monitor-ion chromatography (AIM-IC) system, which provides hourly measurements of the main chemical components of PM2.5 (particulate matter with an aerodynamic diameter<2.5 μm) and its precursor gases, was evaluated and deployed from May to July 2011 and April to December 2013 in the Athabasca Oil Sands Region (AOSR) of northeastern Alberta, Canada. The collection efficiencies for the gas-phase SO2 and HNO3 using the cellulose membrane were 96% and 100%, respectively, and the collection efficiency of NH3 using the nylon membrane was 100%. The AIM-IC was compared with a collocated annular denuder sampling system (ADSS) and a Federal Reference Method (FRM) Partisol PM2.5 sampler. The correlation coefficients of SO4(2-) concentrations between the AIM-IC and ADSS and between the AIM-IC and the Partisol PM2.5 sampler were 0.98 and 0.95, respectively. The comparisons also showed no statistically significant difference between the measurement sets, suggesting that the AIM-IC measurements of the PM2.5 chemical composition are comparable to the ADSS and Partisol PM2.5 methods. NH3 concentration in the summer (mean±standard deviation, 1.9±0.7 µg m(-3)) was higher than in the winter (1.3±0.9 µg m(-3)). HNO3 and NO3- concentrations were generally low in the AOSR, and especially in the winter months. NH4+ (0.94±0.96 µg m(-3)) and SO4(2-) (0.58±0.93 µg m(-3)) were the major ionic species of PM2.5. Direct SO2 emissions from oil sands processing operations influenced ambient particulate NH4+ and SO4(2-) values, with hourly concentrations of NH4+ and SO4(2-) measured downwind (~30 km away from the stack) at 10 and 28 µg m(-3). During the regional forest fire event in 2011, high concentrations of NO3-, NH4+, HNO3, NH3, and PM2.5 were observed and the corresponding maximum hourly concentrations were 31, 15, 9.6, 89, and >450 (the upper limit of PM2.5 measurement) µg m(-3), suggesting the formation of NH4NO3. The AOSR in Canada is one of the most scrutinized industrial regions in the developed world due to the extent of oil extraction activities. Because of this, it is important to accurately assess the effect of these operations on regional air quality. In this study, we compare a new analytical approach, AIM-IC, with more standard analytical approaches to understand how local anthropogenic and nonanthropogenic sources (e.g., forest fires) impact regional air quality. With this approach, we also better characterize PM2.5 composition and its precursor gases to understand secondary aerosol formation mechanisms and to better identify possible control techniques if needed.

  17. 40 CFR 53.16 - Supersession of reference methods.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 5 2010-07-01 2010-07-01 false Supersession of reference methods. 53... (CONTINUED) AMBIENT AIR MONITORING REFERENCE AND EQUIVALENT METHODS General Provisions § 53.16 Supersession of reference methods. (a) This section prescribes procedures and criteria applicable to requests that...

  18. Effect of Initial Iron Content in a Zinc Bath on the Dissolution Rate of Iron During a Hot Dip Galvanizing Process

    NASA Astrophysics Data System (ADS)

    Lee, Sang Myung; Lee, Suk Kyu; Paik, Doo-Jin; Park, Joo Hyun

    2017-04-01

    The mechanism of iron dissolution and the effect of initial Fe content in a Zn bath on the dissolution rate of iron were investigated using a finger rotating method (FRM). When the initial iron content, [Fe]°, in the zinc bath was less than the solubility limit, the iron content in the zinc bath showed a rapid increase, whereas a moderate increase was observed when [Fe]° was close to the solubility limit. Based on Eisenberg's kinetic model, the mass transfer coefficient of iron in the present experimental condition was calculated to be k M = 1.2 × 10-5 m/s, which was similar to the results derived by Giorgi et al. under industrial practice conditions. A dissolution of iron occurred even when the initial iron content in the zinc bath was greater than the solubility limit, which was explained by the interfacial thermodynamics in conjunction with the morphology of the surface coating layer. By analyzing the diffraction patterns using TEM, the outermost dendritic-structured coating layer was confirmed as FeZn13 ( ζ). In order to satisfy the local equilibrium based on the Gibbs-Thomson equation, iron in the dendrite-structured phase spontaneously dissolved into the zinc bath, resulting in the enrichment of iron in front of the dendrite tip. Through the diffusion boundary layer in front of the dendritic-structured layer, dissolved Fe atoms diffused out and reacted with Zn and small amounts of Al, resulting in the formation of dross particles such as FeZn10Al x ( δ). It was experimentally confirmed that the smaller the difference between the initial iron content in the zinc bath and the iron solubility limit at a given temperature, the lower the number of formed dross particles.

  19. Uav and GIS Based Tool for Collection and Propagation of Seeds Material - First Results

    NASA Astrophysics Data System (ADS)

    Stereńczak, K.; Mroczek, P.; Jastrzębowski, S.; Krok, G.; Lisańczuk, M.; Klisz, M.; Kantorowicz, W.

    2016-06-01

    Seed management carried out by The State Forests National Forest Holding is an integral part of rational forest management. Seed collection takes place mainly from stands belonging to first category of forest reproductive material, which is the largest seed base in Poland. In smaller amount, seeds are collected in selective objects of highest forest reproductive material category (selected seed stands, seed orchards). The previous estimation methods of seed crop were based on visual assessment of cones in the stands for their harvest. Following the rules of FRM transfer is additional difficulty of rational seed management which limits the possibility of the use of planting material in Poland. Statements concerning forecast of seed crop and monitoring of seed quality is based on annual reports from the State Forest Service. Forest Research Institute is responsible for preparing and publishing above-mentioned statements. A small extent of its automatization and optimization is a large disadvantage of this procedure. In order to make this process more effective web-based GIS application was designed. Its main performance will give a possibility to upload present-day information on seed efficiency, their spatial pattern and availability. Currently this system is under preparation. As a result, the project team will get a possibility to increase participation of seed material collected from selected seed base and to share good practices on this issue in more efficient way. In the future this will make it possible to obtain greater genetic gain of selection strategy. Additionally, first results presented in literature showed possible use of unmanned aerial system/vehicle (UAS/V) for supporting of seed crop forecast procedure.

  20. Deviation of landmarks in accordance with methods of establishing reference planes in three-dimensional facial CT evaluation.

    PubMed

    Yoon, Kaeng Won; Yoon, Suk-Ja; Kang, Byung-Cheol; Kim, Young-Hee; Kook, Min Suk; Lee, Jae-Seo; Palomo, Juan Martin

    2014-09-01

    This study aimed to investigate the deviation of landmarks from horizontal or midsagittal reference planes according to the methods of establishing reference planes. Computed tomography (CT) scans of 18 patients who received orthodontic and orthognathic surgical treatment were reviewed. Each CT scan was reconstructed by three methods for establishing three orthogonal reference planes (namely, the horizontal, midsagittal, and coronal reference planes). The horizontal (bilateral porions and bilateral orbitales) and midsagittal (crista galli, nasion, prechiasmatic point, opisthion, and anterior nasal spine) landmarks were identified on each CT scan. Vertical deviation of the horizontal landmarks and horizontal deviation of the midsagittal landmarks were measured. The porion and orbitale, which were not involved in establishing the horizontal reference plane, were found to deviate vertically from the horizontal reference plane in the three methods. The midsagittal landmarks, which were not used for the midsagittal reference plane, deviated horizontally from the midsagittal reference plane in the three methods. In a three-dimensional facial analysis, the vertical and horizontal deviations of the landmarks from the horizontal and midsagittal reference planes could vary depending on the methods of establishing reference planes.

  1. A reference estimator based on composite sensor pattern noise for source device identification

    NASA Astrophysics Data System (ADS)

    Li, Ruizhe; Li, Chang-Tsun; Guan, Yu

    2014-02-01

    It has been proved that Sensor Pattern Noise (SPN) can serve as an imaging device fingerprint for source camera identification. Reference SPN estimation is a very important procedure within the framework of this application. Most previous works built reference SPN by averaging the SPNs extracted from 50 images of blue sky. However, this method can be problematic. Firstly, in practice we may face the problem of source camera identification in the absence of the imaging cameras and reference SPNs, which means only natural images with scene details are available for reference SPN estimation rather than blue sky images. It is challenging because the reference SPN can be severely contaminated by image content. Secondly, the number of available reference images sometimes is too few for existing methods to estimate a reliable reference SPN. In fact, existing methods lack consideration of the number of available reference images as they were designed for the datasets with abundant images to estimate the reference SPN. In order to deal with the aforementioned problem, in this work, a novel reference estimator is proposed. Experimental results show that our proposed method achieves better performance than the methods based on the averaged reference SPN, especially when few reference images used.

  2. Reference Value Advisor: a new freeware set of macroinstructions to calculate reference intervals with Microsoft Excel.

    PubMed

    Geffré, Anne; Concordet, Didier; Braun, Jean-Pierre; Trumel, Catherine

    2011-03-01

    International recommendations for determination of reference intervals have been recently updated, especially for small reference sample groups, and use of the robust method and Box-Cox transformation is now recommended. Unfortunately, these methods are not included in most software programs used for data analysis by clinical laboratories. We have created a set of macroinstructions, named Reference Value Advisor, for use in Microsoft Excel to calculate reference limits applying different methods. For any series of data, Reference Value Advisor calculates reference limits (with 90% confidence intervals [CI]) using a nonparametric method when n≥40 and by parametric and robust methods from native and Box-Cox transformed values; tests normality of distributions using the Anderson-Darling test and outliers using Tukey and Dixon-Reed tests; displays the distribution of values in dot plots and histograms and constructs Q-Q plots for visual inspection of normality; and provides minimal guidelines in the form of comments based on international recommendations. The critical steps in determination of reference intervals are correct selection of as many reference individuals as possible and analysis of specimens in controlled preanalytical and analytical conditions. Computing tools cannot compensate for flaws in selection and size of the reference sample group and handling and analysis of samples. However, if those steps are performed properly, Reference Value Advisor, available as freeware at http://www.biostat.envt.fr/spip/spip.php?article63, permits rapid assessment and comparison of results calculated using different methods, including currently unavailable methods. This allows for selection of the most appropriate method, especially as the program provides the CI of limits. It should be useful in veterinary clinical pathology when only small reference sample groups are available. ©2011 American Society for Veterinary Clinical Pathology.

  3. Defining the Reference Condition for Wadeable Streams in the Sand Hills Subdivision of the Southeastern Plains Ecoregion, USA

    NASA Astrophysics Data System (ADS)

    Kosnicki, Ely; Sefick, Stephen A.; Paller, Michael H.; Jarrell, Miller S.; Prusha, Blair A.; Sterrett, Sean C.; Tuberville, Tracey D.; Feminella, Jack W.

    2014-09-01

    The Sand Hills subdivision of the Southeastern Plains ecoregion has been impacted by historical land uses over the past two centuries and, with the additive effects of contemporary land use, determining reference condition for streams in this region is a challenge. We identified reference condition based on the combined use of 3 independent selection methods. Method 1 involved use of a multivariate disturbance gradient derived from several stressors, method 2 was based on variation in channel morphology, and method 3 was based on passing 6 of 7 environmental criteria. Sites selected as reference from all 3 methods were considered primary reference, whereas those selected by 2 or 1 methods were considered secondary or tertiary reference, respectively. Sites not selected by any of the methods were considered non-reference. In addition, best professional judgment (BPJ) was used to exclude some sites from any reference class, and comparisons were made to examine the utility of BPJ. Non-metric multidimensional scaling indicated that use of BPJ may help designate non-reference sites when unidentified stressors are present. The macroinvertebrate community measures Ephemeroptera, Plecoptera, Trichoptera richness and North Carolina Biotic Index showed no differences between primary and secondary reference sites when BPJ was ignored. However, there was no significant difference among primary, secondary, and tertiary reference sites when BPJ was used. We underscore the importance of classifying reference conditions, especially in regions that have endured significant anthropogenic activity. We suggest that the use of secondary reference sites may enable construction of models that target a broader set of management interests.

  4. Resampling methods in Microsoft Excel® for estimating reference intervals

    PubMed Central

    Theodorsson, Elvar

    2015-01-01

    Computer- intensive resampling/bootstrap methods are feasible when calculating reference intervals from non-Gaussian or small reference samples. Microsoft Excel® in version 2010 or later includes natural functions, which lend themselves well to this purpose including recommended interpolation procedures for estimating 2.5 and 97.5 percentiles.
The purpose of this paper is to introduce the reader to resampling estimation techniques in general and in using Microsoft Excel® 2010 for the purpose of estimating reference intervals in particular.
Parametric methods are preferable to resampling methods when the distributions of observations in the reference samples is Gaussian or can transformed to that distribution even when the number of reference samples is less than 120. Resampling methods are appropriate when the distribution of data from the reference samples is non-Gaussian and in case the number of reference individuals and corresponding samples are in the order of 40. At least 500-1000 random samples with replacement should be taken from the results of measurement of the reference samples. PMID:26527366

  5. Resampling methods in Microsoft Excel® for estimating reference intervals.

    PubMed

    Theodorsson, Elvar

    2015-01-01

    Computer-intensive resampling/bootstrap methods are feasible when calculating reference intervals from non-Gaussian or small reference samples. Microsoft Excel® in version 2010 or later includes natural functions, which lend themselves well to this purpose including recommended interpolation procedures for estimating 2.5 and 97.5 percentiles. 
The purpose of this paper is to introduce the reader to resampling estimation techniques in general and in using Microsoft Excel® 2010 for the purpose of estimating reference intervals in particular.
 Parametric methods are preferable to resampling methods when the distributions of observations in the reference samples is Gaussian or can transformed to that distribution even when the number of reference samples is less than 120. Resampling methods are appropriate when the distribution of data from the reference samples is non-Gaussian and in case the number of reference individuals and corresponding samples are in the order of 40. At least 500-1000 random samples with replacement should be taken from the results of measurement of the reference samples.

  6. 46 CFR 160.176-4 - Incorporation by reference.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... and Elongation, Breaking of Woven Cloth; Grab Method, incorporation by reference approved for § 160.176-13. (ii) Method 5132, Strength of Cloth, Tearing; Falling-Pendulum Method, incorporation by reference approved for § 160.176-13. (iii) Method 5134, Strength of Cloth, Tearing; Tongue Method...

  7. 46 CFR 160.176-4 - Incorporation by reference.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... and Elongation, Breaking of Woven Cloth; Grab Method, incorporation by reference approved for § 160.176-13. (ii) Method 5132, Strength of Cloth, Tearing; Falling-Pendulum Method, incorporation by reference approved for § 160.176-13. (iii) Method 5134, Strength of Cloth, Tearing; Tongue Method...

  8. US Fish and Wildlife Service biomonitoring operations manual, Appendices A--K

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gianotto, D.F.; Rope, R.C.; Mondecar, M.

    1993-04-01

    Volume 2 contains Appendices and Summary Sheets for the following areas: A-Legislative Background and Key to Relevant Legislation, B- Biomonitoring Operations Workbook, C-Air Monitoring, D-Introduction to the Flora and Fauna for Biomonitoring, E-Decontamination Guidance Reference Field Methods, F-Documentation Guidance, Sample Handling, and Quality Assurance/Quality Control Standard Operating Procedures, G-Field Instrument Measurements Reference Field Methods, H-Ground Water Sampling Reference Field Methods, I-Sediment Sampling Reference Field Methods, J-Soil Sampling Reference Field Methods, K-Surface Water Reference Field Methods. Appendix B explains how to set up strategy to enter information on the ``disk workbook``. Appendix B is enhanced by DE97006389, an on-line workbook formore » users to be able to make revisions to their own biomonitoring data.« less

  9. Applying design principles to fusion reactor configurations for propulsion in space

    NASA Technical Reports Server (NTRS)

    Carpenter, Scott A.; Deveny, Marc E.; Schulze, Norman R.

    1993-01-01

    The application of fusion power to space propulsion requires rethinking the engineering-design solution to controlled-fusion energy. Whereas the unit cost of electricity (COE) drives the engineering-design solution for utility-based fusion reactor configurations; initial mass to low earth orbit (IMLEO), specific jet power (kW(thrust)/kg(engine)), and reusability drive the engineering-design solution for successful application of fusion power to space propulsion. We applied three design principles (DP's) to adapt and optimize three candidate-terrestrial-fusion-reactor configurations for propulsion in space. The three design principles are: provide maximum direct access to space for waste radiation, operate components as passive radiators to minimize cooling-system mass, and optimize the plasma fuel, fuel mix, and temperature for best specific jet power. The three candidate terrestrial fusion reactor configurations are: the thermal barrier tandem mirror (TBTM), field reversed mirror (FRM), and levitated dipole field (LDF). The resulting three candidate space fusion propulsion systems have their IMLEO minimized and their specific jet power and reusability maximized. We performed a preliminary rating of these configurations and concluded that the leading engineering-design solution to space fusion propulsion is a modified TBTM that we call the Mirror Fusion Propulsion System (MFPS).

  10. Self-triggering readout system for the neutron lifetime experiment PENeLOPE

    NASA Astrophysics Data System (ADS)

    Gaisbauer, D.; Bai, Y.; Konorov, I.; Paul, S.; Steffen, D.

    2016-02-01

    PENeLOPE is a neutron lifetime measurement developed at the Technische Universität München and located at the Forschungs-Neutronenquelle Heinz Maier-Leibnitz (FRM II) aiming to achieve a precision of 0.1 seconds. The detector for PENeLOPE consists of about 1250 Avalanche Photodiodes (APDs) with a total active area of 1225 cm2. The decay proton detector and electronics will be operated at a high electrostatic potential of -30 kV and a magnetic field of 0.6 T. This includes shaper, preamplifier, ADC and FPGA cards. In addition, the APDs will be cooled to 77 K. The 1250 APDs are divided into 14 groups of 96 channels, including spares. A 12-bit ADC digitizes the detector signals with 1 MSps. A firmware was developed for the detector including a self-triggering readout with continuous pedestal calculation and configurable signal detection. The data transmission and configuration is done via the Switched Enabling Protocol (SEP). It is a time-division multiplexing low layer protocol which provides determined latency for time critical messages, IPBus, and JTAG interfaces. The network has a n:1 topology, reducing the number of optical links.

  11. [Study on the experimental application of floating-reference method to noninvasive blood glucose sensing].

    PubMed

    Yu, Hui; Qi, Dan; Li, Heng-da; Xu, Ke-xin; Yuan, Wei-jie

    2012-03-01

    Weak signal, low instrument signal-to-noise ratio, continuous variation of human physiological environment and the interferences from other components in blood make it difficult to extract the blood glucose information from near infrared spectrum in noninvasive blood glucose measurement. The floating-reference method, which analyses the effect of glucose concentration variation on absorption coefficient and scattering coefficient, gets spectrum at the reference point and the measurement point where the light intensity variations from absorption and scattering are counteractive and biggest respectively. By using the spectrum from reference point as reference, floating-reference method can reduce the interferences from variation of physiological environment and experiment circumstance. In the present paper, the effectiveness of floating-reference method working on improving prediction precision and stability was assessed through application experiments. The comparison was made between models whose data were processed with and without floating-reference method. The results showed that the root mean square error of prediction (RMSEP) decreased by 34.7% maximally. The floating-reference method could reduce the influences of changes of samples' state, instrument noises and drift, and improve the models' prediction precision and stability effectively.

  12. 40 CFR Table E-1 to Subpart E of... - Summary of Test Requirements for Reference and Class I Equivalent Methods for PM2.5 and PM10-2.5

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Reference and Class I Equivalent Methods for PM2.5 and PM10-2.5 E Table E-1 to Subpart E of Part 53... MONITORING REFERENCE AND EQUIVALENT METHODS Procedures for Testing Physical (Design) and Performance Characteristics of Reference Methods and Class I and Class II Equivalent Methods for PM2.5 or PM10â2.5 Pt. 53...

  13. Direct-to-digital holography reduction of reference hologram noise and fourier space smearing

    DOEpatents

    Voelkl, Edgar

    2006-06-27

    Systems and methods are described for reduction of reference hologram noise and reduction of Fourier space smearing, especially in the context of direct-to-digital holography (off-axis interferometry). A method of reducing reference hologram noise includes: recording a plurality of reference holograms; processing the plurality of reference holograms into a corresponding plurality of reference image waves; and transforming the corresponding plurality of reference image waves into a reduced noise reference image wave. A method of reducing smearing in Fourier space includes: recording a plurality of reference holograms; processing the plurality of reference holograms into a corresponding plurality of reference complex image waves; transforming the corresponding plurality of reference image waves into a reduced noise reference complex image wave; recording a hologram of an object; processing the hologram of the object into an object complex image wave; and dividing the complex image wave of the object by the reduced noise reference complex image wave to obtain a reduced smearing object complex image wave.

  14. [The validation of the effect of correcting spectral background changes based on floating reference method by simulation].

    PubMed

    Wang, Zhu-lou; Zhang, Wan-jie; Li, Chen-xi; Chen, Wen-liang; Xu, Ke-xin

    2015-02-01

    There are some challenges in near-infrared non-invasive blood glucose measurement, such as the low signal to noise ratio of instrument, the unstable measurement conditions, the unpredictable and irregular changes of the measured object, and etc. Therefore, it is difficult to extract the information of blood glucose concentrations from the complicated signals accurately. Reference measurement method is usually considered to be used to eliminate the effect of background changes. But there is no reference substance which changes synchronously with the anylate. After many years of research, our research group has proposed the floating reference method, which is succeeded in eliminating the spectral effects induced by the instrument drifts and the measured object's background variations. But our studies indicate that the reference-point will changes following the changing of measurement location and wavelength. Therefore, the effects of floating reference method should be verified comprehensively. In this paper, keeping things simple, the Monte Carlo simulation employing Intralipid solution with the concentrations of 5% and 10% is performed to verify the effect of floating reference method used into eliminating the consequences of the light source drift. And the light source drift is introduced through varying the incident photon number. The effectiveness of the floating reference method with corresponding reference-points at different wavelengths in eliminating the variations of the light source drift is estimated. The comparison of the prediction abilities of the calibration models with and without using this method shows that the RMSEPs of the method are decreased by about 98.57% (5%Intralipid)and 99.36% (10% Intralipid)for different Intralipid. The results indicate that the floating reference method has obvious effect in eliminating the background changes.

  15. Intra prediction using face continuity in 360-degree video coding

    NASA Astrophysics Data System (ADS)

    Hanhart, Philippe; He, Yuwen; Ye, Yan

    2017-09-01

    This paper presents a new reference sample derivation method for intra prediction in 360-degree video coding. Unlike the conventional reference sample derivation method for 2D video coding, which uses the samples located directly above and on the left of the current block, the proposed method considers the spherical nature of 360-degree video when deriving reference samples located outside the current face to which the block belongs, and derives reference samples that are geometric neighbors on the sphere. The proposed reference sample derivation method was implemented in the Joint Exploration Model 3.0 (JEM-3.0) for the cubemap projection format. Simulation results for the all intra configuration show that, when compared with the conventional reference sample derivation method, the proposed method gives, on average, luma BD-rate reduction of 0.3% in terms of the weighted spherical PSNR (WS-PSNR) and spherical PSNR (SPSNR) metrics.

  16. Measurement of susceptibility artifacts with histogram-based reference value on magnetic resonance images according to standard ASTM F2119.

    PubMed

    Heinrich, Andreas; Teichgräber, Ulf K; Güttler, Felix V

    2015-12-01

    The standard ASTM F2119 describes a test method for measuring the size of a susceptibility artifact based on the example of a passive implant. A pixel in an image is considered to be a part of an image artifact if the intensity is changed by at least 30% in the presence of a test object, compared to a reference image in which the test object is absent (reference value). The aim of this paper is to simplify and accelerate the test method using a histogram-based reference value. Four test objects were scanned parallel and perpendicular to the main magnetic field, and the largest susceptibility artifacts were measured using two methods of reference value determination (reference image-based and histogram-based reference value). The results between both methods were compared using the Mann-Whitney U-test. The difference between both reference values was 42.35 ± 23.66. The difference of artifact size was 0.64 ± 0.69 mm. The artifact sizes of both methods did not show significant differences; the p-value of the Mann-Whitney U-test was between 0.710 and 0.521. A standard-conform method for a rapid, objective, and reproducible evaluation of susceptibility artifacts could be implemented. The result of the histogram-based method does not significantly differ from the ASTM-conform method.

  17. 40 CFR 75.22 - Reference test methods.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 17 2012-07-01 2012-07-01 false Reference test methods. 75.22 Section...) CONTINUOUS EMISSION MONITORING Operation and Maintenance Requirements § 75.22 Reference test methods. (a) The owner or operator shall use the following methods, which are found in appendices A-1 through A-4 to part...

  18. 7 CFR 801.7 - Reference methods and tolerances for near-infrared spectroscopy (NIRS) analyzers.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 7 2010-01-01 2010-01-01 false Reference methods and tolerances for near-infrared spectroscopy (NIRS) analyzers. 801.7 Section 801.7 Agriculture Regulations of the Department of Agriculture... methods and tolerances for near-infrared spectroscopy (NIRS) analyzers. (a) Reference methods. (1) The...

  19. 78 FR 40000 - Method for the Determination of Lead in Total Suspended Particulate Matter

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-03

    .... Purpose of the New Reference Method B. Rationale for Selection of the New Reference Method C. Comments on.../files/ambient/criteria/reference-equivalent-methods-list.pdf . C. Comments on the Proposed Rule On... information collection requirements beyond those imposed by the existing Pb monitoring requirements. C...

  20. A self-reference PRF-shift MR thermometry method utilizing the phase gradient

    NASA Astrophysics Data System (ADS)

    Langley, Jason; Potter, William; Phipps, Corey; Huang, Feng; Zhao, Qun

    2011-12-01

    In magnetic resonance (MR) imaging, the most widely used and accurate method for measuring temperature is based on the shift in proton resonance frequency (PRF). However, inter-scan motion and bulk magnetic field shifts can lead to inaccurate temperature measurements in the PRF-shift MR thermometry method. The self-reference PRF-shift MR thermometry method was introduced to overcome such problems by deriving a reference image from the heated or treated image, and approximates the reference phase map with low-order polynomial functions. In this note, a new approach is presented to calculate the baseline phase map in self-reference PRF-shift MR thermometry. The proposed method utilizes the phase gradient to remove the phase unwrapping step inherent to other self-reference PRF-shift MR thermometry methods. The performance of the proposed method was evaluated using numerical simulations with temperature distributions following a two-dimensional Gaussian function as well as phantom and in vivo experimental data sets. The results from both the numerical simulations and experimental data show that the proposed method is a promising technique for measuring temperature.

  1. Examination of a Method to Determine the Reference Region for Calculating the Specific Binding Ratio in Dopamine Transporter Imaging.

    PubMed

    Watanabe, Ayumi; Inoue, Yusuke; Asano, Yuji; Kikuchi, Kei; Miyatake, Hiroki; Tokushige, Takanobu

    2017-01-01

    The specific binding ratio (SBR) was first reported by Tossici-Bolt et al. for quantitative indicators for dopamine transporter (DAT) imaging. It is defined as the ratio of the specific binding concentration of the striatum to the non-specific binding concentration of the whole brain other than the striatum. The non-specific binding concentration is calculated based on the region of interest (ROI), which is set 20 mm inside the outer contour, defined by a threshold technique. Tossici-Bolt et al. used a 50% threshold, but sometimes we couldn't define the ROI of non-specific binding concentration (reference region) and calculate SBR appropriately with a 50% threshold. Therefore, we sought a new method for determining the reference region when calculating SBR. We used data from 20 patients who had undergone DAT imaging in our hospital, to calculate the non-specific binding concentration by the following methods, the threshold to define a reference region was fixed at some specific values (the fixing method) and reference region was visually optimized by an examiner at every examination (the visual optimization method). First, we assessed the reference region of each method visually, and afterward, we quantitatively compared SBR calculated based on each method. In the visual assessment, the scores of the fixing method at 30% and visual optimization method were higher than the scores of the fixing method at other values, with or without scatter correction. In the quantitative assessment, the SBR obtained by visual optimization of the reference region, based on consensus of three radiological technologists, was used as a baseline (the standard method). The values of SBR showed good agreement between the standard method and both the fixing method at 30% and the visual optimization method, with or without scatter correction. Therefore, the fixing method at 30% and the visual optimization method were equally suitable for determining the reference region.

  2. 40 CFR 53.11 - Cancellation of reference or equivalent method designation.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 5 2010-07-01 2010-07-01 false Cancellation of reference or equivalent method designation. 53.11 Section 53.11 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) AMBIENT AIR MONITORING REFERENCE AND EQUIVALENT METHODS General...

  3. Fast lossless compression via cascading Bloom filters

    PubMed Central

    2014-01-01

    Background Data from large Next Generation Sequencing (NGS) experiments present challenges both in terms of costs associated with storage and in time required for file transfer. It is sometimes possible to store only a summary relevant to particular applications, but generally it is desirable to keep all information needed to revisit experimental results in the future. Thus, the need for efficient lossless compression methods for NGS reads arises. It has been shown that NGS-specific compression schemes can improve results over generic compression methods, such as the Lempel-Ziv algorithm, Burrows-Wheeler transform, or Arithmetic Coding. When a reference genome is available, effective compression can be achieved by first aligning the reads to the reference genome, and then encoding each read using the alignment position combined with the differences in the read relative to the reference. These reference-based methods have been shown to compress better than reference-free schemes, but the alignment step they require demands several hours of CPU time on a typical dataset, whereas reference-free methods can usually compress in minutes. Results We present a new approach that achieves highly efficient compression by using a reference genome, but completely circumvents the need for alignment, affording a great reduction in the time needed to compress. In contrast to reference-based methods that first align reads to the genome, we hash all reads into Bloom filters to encode, and decode by querying the same Bloom filters using read-length subsequences of the reference genome. Further compression is achieved by using a cascade of such filters. Conclusions Our method, called BARCODE, runs an order of magnitude faster than reference-based methods, while compressing an order of magnitude better than reference-free methods, over a broad range of sequencing coverage. In high coverage (50-100 fold), compared to the best tested compressors, BARCODE saves 80-90% of the running time while only increasing space slightly. PMID:25252952

  4. Fast lossless compression via cascading Bloom filters.

    PubMed

    Rozov, Roye; Shamir, Ron; Halperin, Eran

    2014-01-01

    Data from large Next Generation Sequencing (NGS) experiments present challenges both in terms of costs associated with storage and in time required for file transfer. It is sometimes possible to store only a summary relevant to particular applications, but generally it is desirable to keep all information needed to revisit experimental results in the future. Thus, the need for efficient lossless compression methods for NGS reads arises. It has been shown that NGS-specific compression schemes can improve results over generic compression methods, such as the Lempel-Ziv algorithm, Burrows-Wheeler transform, or Arithmetic Coding. When a reference genome is available, effective compression can be achieved by first aligning the reads to the reference genome, and then encoding each read using the alignment position combined with the differences in the read relative to the reference. These reference-based methods have been shown to compress better than reference-free schemes, but the alignment step they require demands several hours of CPU time on a typical dataset, whereas reference-free methods can usually compress in minutes. We present a new approach that achieves highly efficient compression by using a reference genome, but completely circumvents the need for alignment, affording a great reduction in the time needed to compress. In contrast to reference-based methods that first align reads to the genome, we hash all reads into Bloom filters to encode, and decode by querying the same Bloom filters using read-length subsequences of the reference genome. Further compression is achieved by using a cascade of such filters. Our method, called BARCODE, runs an order of magnitude faster than reference-based methods, while compressing an order of magnitude better than reference-free methods, over a broad range of sequencing coverage. In high coverage (50-100 fold), compared to the best tested compressors, BARCODE saves 80-90% of the running time while only increasing space slightly.

  5. Reference values assessment in a Mediterranean population for small dense low-density lipoprotein concentration isolated by an optimized precipitation method.

    PubMed

    Fernández-Cidón, Bárbara; Padró-Miquel, Ariadna; Alía-Ramos, Pedro; Castro-Castro, María José; Fanlo-Maresma, Marta; Dot-Bach, Dolors; Valero-Politi, José; Pintó-Sala, Xavier; Candás-Estébanez, Beatriz

    2017-01-01

    High serum concentrations of small dense low-density lipoprotein cholesterol (sd-LDL-c) particles are associated with risk of cardiovascular disease (CVD). Their clinical application has been hindered as a consequence of the laborious current method used for their quantification. Optimize a simple and fast precipitation method to isolate sd-LDL particles and establish a reference interval in a Mediterranean population. Forty-five serum samples were collected, and sd-LDL particles were isolated using a modified heparin-Mg 2+ precipitation method. sd-LDL-c concentration was calculated by subtracting high-density lipoprotein cholesterol (HDL-c) from the total cholesterol measured in the supernatant. This method was compared with the reference method (ultracentrifugation). Reference values were estimated according to the Clinical and Laboratory Standards Institute and The International Federation of Clinical Chemistry and Laboratory Medicine recommendations. sd-LDL-c concentration was measured in serums from 79 subjects with no lipid metabolism abnormalities. The Passing-Bablok regression equation is y = 1.52 (0.72 to 1.73) + 0.07 x (-0.1 to 0.13), demonstrating no significant statistical differences between the modified precipitation method and the ultracentrifugation reference method. Similarly, no differences were detected when considering only sd-LDL-c from dyslipidemic patients, since the modifications added to the precipitation method facilitated the proper sedimentation of triglycerides and other lipoproteins. The reference interval for sd-LDL-c concentration estimated in a Mediterranean population was 0.04-0.47 mmol/L. An optimization of the heparin-Mg 2+ precipitation method for sd-LDL particle isolation was performed, and reference intervals were established in a Spanish Mediterranean population. Measured values were equivalent to those obtained with the reference method, assuring its clinical application when tested in both normolipidemic and dyslipidemic subjects.

  6. Selection of reference standard during method development using the analytical hierarchy process.

    PubMed

    Sun, Wan-yang; Tong, Ling; Li, Dong-xiang; Huang, Jing-yi; Zhou, Shui-ping; Sun, Henry; Bi, Kai-shun

    2015-03-25

    Reference standard is critical for ensuring reliable and accurate method performance. One important issue is how to select the ideal one from the alternatives. Unlike the optimization of parameters, the criteria of the reference standard are always immeasurable. The aim of this paper is to recommend a quantitative approach for the selection of reference standard during method development based on the analytical hierarchy process (AHP) as a decision-making tool. Six alternative single reference standards were assessed in quantitative analysis of six phenolic acids from Salvia Miltiorrhiza and its preparations by using ultra-performance liquid chromatography. The AHP model simultaneously considered six criteria related to reference standard characteristics and method performance, containing feasibility to obtain, abundance in samples, chemical stability, accuracy, precision and robustness. The priority of each alternative was calculated using standard AHP analysis method. The results showed that protocatechuic aldehyde is the ideal reference standard, and rosmarinic acid is about 79.8% ability as the second choice. The determination results successfully verified the evaluation ability of this model. The AHP allowed us comprehensive considering the benefits and risks of the alternatives. It was an effective and practical tool for optimization of reference standards during method development. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. 40 CFR 53.14 - Modification of a reference or equivalent method.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 5 2010-07-01 2010-07-01 false Modification of a reference or equivalent method. 53.14 Section 53.14 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) AMBIENT AIR MONITORING REFERENCE AND EQUIVALENT METHODS General Provisions...

  8. 40 CFR 53.8 - Designation of reference and equivalent methods.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 5 2010-07-01 2010-07-01 false Designation of reference and equivalent methods. 53.8 Section 53.8 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) AMBIENT AIR MONITORING REFERENCE AND EQUIVALENT METHODS General Provisions § 53.8...

  9. 10 CFR 434.505 - Reference building method.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 3 2013-01-01 2013-01-01 false Reference building method. 434.505 Section 434.505 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.505 Reference building method. 505...

  10. 10 CFR 434.505 - Reference building method.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 3 2014-01-01 2014-01-01 false Reference building method. 434.505 Section 434.505 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.505 Reference building method. 505.1...

  11. 10 CFR 434.505 - Reference building method.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 3 2012-01-01 2012-01-01 false Reference building method. 434.505 Section 434.505 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.505 Reference building method. 505...

  12. 10 CFR 434.505 - Reference building method.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 3 2011-01-01 2011-01-01 false Reference building method. 434.505 Section 434.505 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.505 Reference building method. 505...

  13. 10 CFR 434.505 - Reference building method.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Reference building method. 434.505 Section 434.505 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.505 Reference building method. 505...

  14. The Kjeldahl method as a primary reference procedure for total protein in certified reference materials used in clinical chemistry. I. A review of Kjeldahl methods adopted by laboratory medicine.

    PubMed

    Chromý, Vratislav; Vinklárková, Bára; Šprongl, Luděk; Bittová, Miroslava

    2015-01-01

    We found previously that albumin-calibrated total protein in certified reference materials causes unacceptable positive bias in analysis of human sera. The simplest way to cure this defect is the use of human-based serum/plasma standards calibrated by the Kjeldahl method. Such standards, commutative with serum samples, will compensate for bias caused by lipids and bilirubin in most human sera. To find a suitable primary reference procedure for total protein in reference materials, we reviewed Kjeldahl methods adopted by laboratory medicine. We found two methods recommended for total protein in human samples: an indirect analysis based on total Kjeldahl nitrogen corrected for its nonprotein nitrogen and a direct analysis made on isolated protein precipitates. The methods found will be assessed in a subsequent article.

  15. Valid analytical performance specifications for combined analytical bias and imprecision for the use of common reference intervals.

    PubMed

    Hyltoft Petersen, Per; Lund, Flemming; Fraser, Callum G; Sandberg, Sverre; Sölétormos, György

    2018-01-01

    Background Many clinical decisions are based on comparison of patient results with reference intervals. Therefore, an estimation of the analytical performance specifications for the quality that would be required to allow sharing common reference intervals is needed. The International Federation of Clinical Chemistry (IFCC) recommended a minimum of 120 reference individuals to establish reference intervals. This number implies a certain level of quality, which could then be used for defining analytical performance specifications as the maximum combination of analytical bias and imprecision required for sharing common reference intervals, the aim of this investigation. Methods Two methods were investigated for defining the maximum combination of analytical bias and imprecision that would give the same quality of common reference intervals as the IFCC recommendation. Method 1 is based on a formula for the combination of analytical bias and imprecision and Method 2 is based on the Microsoft Excel formula NORMINV including the fractional probability of reference individuals outside each limit and the Gaussian variables of mean and standard deviation. The combinations of normalized bias and imprecision are illustrated for both methods. The formulae are identical for Gaussian and log-Gaussian distributions. Results Method 2 gives the correct results with a constant percentage of 4.4% for all combinations of bias and imprecision. Conclusion The Microsoft Excel formula NORMINV is useful for the estimation of analytical performance specifications for both Gaussian and log-Gaussian distributions of reference intervals.

  16. Comparison of three commercially available fit-test methods.

    PubMed

    Janssen, Larry L; Luinenburg, D Michael; Mullins, Haskell E; Nelson, Thomas J

    2002-01-01

    American National Standards Institute (ANSI) standard Z88.10, Respirator Fit Testing Methods, includes criteria to evaluate new fit-tests. The standard allows generated aerosol, particle counting, or controlled negative pressure quantitative fit-tests to be used as the reference method to determine acceptability of a new test. This study examined (1) comparability of three Occupational Safety and Health Administration-accepted fit-test methods, all of which were validated using generated aerosol as the reference method; and (2) the effect of the reference method on the apparent performance of a fit-test method under evaluation. Sequential fit-tests were performed using the controlled negative pressure and particle counting quantitative fit-tests and the bitter aerosol qualitative fit-test. Of 75 fit-tests conducted with each method, the controlled negative pressure method identified 24 failures; bitter aerosol identified 22 failures; and the particle counting method identified 15 failures. The sensitivity of each method, that is, agreement with the reference method in identifying unacceptable fits, was calculated using each of the other two methods as the reference. None of the test methods met the ANSI sensitivity criterion of 0.95 or greater when compared with either of the other two methods. These results demonstrate that (1) the apparent performance of any fit-test depends on the reference method used, and (2) the fit-tests evaluated use different criteria to identify inadequately fitting respirators. Although "acceptable fit" cannot be defined in absolute terms at this time, the ability of existing fit-test methods to reject poor fits can be inferred from workplace protection factor studies.

  17. A simple method for HPLC retention time prediction: linear calibration using two reference substances.

    PubMed

    Sun, Lei; Jin, Hong-Yu; Tian, Run-Tao; Wang, Ming-Juan; Liu, Li-Na; Ye, Liu-Ping; Zuo, Tian-Tian; Ma, Shuang-Cheng

    2017-01-01

    Analysis of related substances in pharmaceutical chemicals and multi-components in traditional Chinese medicines needs bulk of reference substances to identify the chromatographic peaks accurately. But the reference substances are costly. Thus, the relative retention (RR) method has been widely adopted in pharmacopoeias and literatures for characterizing HPLC behaviors of those reference substances unavailable. The problem is it is difficult to reproduce the RR on different columns due to the error between measured retention time (t R ) and predicted t R in some cases. Therefore, it is useful to develop an alternative and simple method for prediction of t R accurately. In the present study, based on the thermodynamic theory of HPLC, a method named linear calibration using two reference substances (LCTRS) was proposed. The method includes three steps, procedure of two points prediction, procedure of validation by multiple points regression and sequential matching. The t R of compounds on a HPLC column can be calculated by standard retention time and linear relationship. The method was validated in two medicines on 30 columns. It was demonstrated that, LCTRS method is simple, but more accurate and more robust on different HPLC columns than RR method. Hence quality standards using LCTRS method are easy to reproduce in different laboratories with lower cost of reference substances.

  18. Local source impacts on primary and secondary aerosols in the Midwestern United States

    NASA Astrophysics Data System (ADS)

    Jayarathne, Thilina; Rathnayake, Chathurika M.; Stone, Elizabeth A.

    2016-04-01

    Atmospheric particulate matter (PM) exhibits heterogeneity in composition across urban areas, leading to poor representation of outdoor air pollutants in human exposure assessments. To examine heterogeneity in PM composition and sources across an urban area, fine particulate matter samples (PM2.5) were chemically profiled in Iowa City, IA from 25 August to 10 November 2011 at two monitoring stations. The urban site is the federal reference monitoring (FRM) station in the city center and the peri-urban site is located 8.0 km to the west on the city edge. Measurements of PM2.5 carbonaceous aerosol, inorganic ions, molecular markers for primary sources, and secondary organic aerosol (SOA) tracers were used to assess statistical differences in composition and sources across the two sites. PM2.5 mass ranged from 3 to 26 μg m-3 during this period, averaging 11.2 ± 4.9 μg m-3 (n = 71). Major components of PM2.5 at the urban site included organic carbon (OC; 22%), ammonium (14%), sulfate (13%), nitrate (7%), calcium (2.9%), and elemental carbon (EC; 2.2%). Periods of elevated PM were driven by increases in ammonium, sulfate, and SOA tracers that coincided with hot and dry conditions and southerly winds. Chemical mass balance (CMB) modeling was used to apportion OC to primary sources; biomass burning, vegetative detritus, diesel engines, and gasoline engines accounted for 28% of OC at the urban site and 24% of OC at the peri-urban site. Secondary organic carbon from isoprene and monoterpene SOA accounted for an additional 13% and 6% of OC at the urban and peri-urban sites, respectively. Differences in biogenic SOA across the two sites were associated with enhanced combustion activities in the urban area and higher aerosol acidity at the urban site. Major PM constituents (e.g., OC, ammonium, sulfate) were generally well-represented by a single monitoring station, indicating a regional source influence. Meanwhile, nitrate, biomass burning, food cooking, suspended dust, and biogenic SOA were not well-represented by a single site and demonstrated local influences. For isoprene SOA, product distributions indicated a larger role for the high-NOx pathway at the urban site. These local sources are largely responsible for differences in population exposures to outdoor PM in the study domain located within the Midwestern US.

  19. Standard setting: comparison of two methods.

    PubMed

    George, Sanju; Haque, M Sayeed; Oyebode, Femi

    2006-09-14

    The outcome of assessments is determined by the standard-setting method used. There is a wide range of standard-setting methods and the two used most extensively in undergraduate medical education in the UK are the norm-reference and the criterion-reference methods. The aims of the study were to compare these two standard-setting methods for a multiple-choice question examination and to estimate the test-retest and inter-rater reliability of the modified Angoff method. The norm-reference method of standard-setting (mean minus 1 SD) was applied to the 'raw' scores of 78 4th-year medical students on a multiple-choice examination (MCQ). Two panels of raters also set the standard using the modified Angoff method for the same multiple-choice question paper on two occasions (6 months apart). We compared the pass/fail rates derived from the norm reference and the Angoff methods and also assessed the test-retest and inter-rater reliability of the modified Angoff method. The pass rate with the norm-reference method was 85% (66/78) and that by the Angoff method was 100% (78 out of 78). The percentage agreement between Angoff method and norm-reference was 78% (95% CI 69% - 87%). The modified Angoff method had an inter-rater reliability of 0.81-0.82 and a test-retest reliability of 0.59-0.74. There were significant differences in the outcomes of these two standard-setting methods, as shown by the difference in the proportion of candidates that passed and failed the assessment. The modified Angoff method was found to have good inter-rater reliability and moderate test-retest reliability.

  20. Cross-reference identification within a PDF document

    NASA Astrophysics Data System (ADS)

    Li, Sida; Gao, Liangcai; Tang, Zhi; Yu, Yinyan

    2015-01-01

    Cross-references, such like footnotes, endnotes, figure/table captions, references, are a common and useful type of page elements to further explain their corresponding entities in the target document. In this paper, we focus on cross-reference identification in a PDF document, and present a robust method as a case study of identifying footnotes and figure references. The proposed method first extracts footnotes and figure captions, and then matches them with their corresponding references within a document. A number of novel features within a PDF document, i.e., page layout, font information, lexical and linguistic features of cross-references, are utilized for the task. Clustering is adopted to handle the features that are stable in one document but varied in different kinds of documents so that the process of identification is adaptive with document types. In addition, this method leverages results from the matching process to provide feedback to the identification process and further improve the algorithm accuracy. The primary experiments in real document sets show that the proposed method is promising to identify cross-reference in a PDF document.

  1. Evaluation of Gas-filled Ionization Chamber Method for Radon Measurement at Two Reference Facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ishikawa, Tetsuo; Tokonami, Shinji; Kobayashi, Yosuke

    2008-08-07

    For quality assurance, gas-filled ionization chamber method was tested at two reference facilities for radon calibration: EML (USA) and PTB (Germany). Consequently, the radon concentrations estimated by the ionization chamber method were in good agreement with the reference radon concentrations provided by EML as well as PTB.

  2. Calibration procedure of Hukseflux SR25 to Establish the Diffuse Reference for the Outdoor Broadband Radiometer Calibration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reda, Ibrahim M.; Andreas, Afshin M.

    2017-08-01

    Accurate pyranometer calibrations, traceable to internationally recognized standards, are critical for solar irradiance measurements. One calibration method is the component summation method, where the pyranometers are calibrated outdoors under clear sky conditions, and the reference global solar irradiance is calculated as the sum of two reference components, the diffuse horizontal and subtended beam solar irradiances. The beam component is measured with pyrheliometers traceable to the World Radiometric Reference, while there is no internationally recognized reference for the diffuse component. In the absence of such a reference, we present a method to consistently calibrate pyranometers for measuring the diffuse component. Themore » method is based on using a modified shade/unshade method and a pyranometer with less than 0.5 W/m2 thermal offset. The calibration result shows that the responsivity of Hukseflux SR25 pyranometer equals 10.98 uV/(W/m2) with +/-0.86 percent uncertainty.« less

  3. Estimation of reference intervals from small samples: an example using canine plasma creatinine.

    PubMed

    Geffré, A; Braun, J P; Trumel, C; Concordet, D

    2009-12-01

    According to international recommendations, reference intervals should be determined from at least 120 reference individuals, which often are impossible to achieve in veterinary clinical pathology, especially for wild animals. When only a small number of reference subjects is available, the possible bias cannot be known and the normality of the distribution cannot be evaluated. A comparison of reference intervals estimated by different methods could be helpful. The purpose of this study was to compare reference limits determined from a large set of canine plasma creatinine reference values, and large subsets of this data, with estimates obtained from small samples selected randomly. Twenty sets each of 120 and 27 samples were randomly selected from a set of 1439 plasma creatinine results obtained from healthy dogs in another study. Reference intervals for the whole sample and for the large samples were determined by a nonparametric method. The estimated reference limits for the small samples were minimum and maximum, mean +/- 2 SD of native and Box-Cox-transformed values, 2.5th and 97.5th percentiles by a robust method on native and Box-Cox-transformed values, and estimates from diagrams of cumulative distribution functions. The whole sample had a heavily skewed distribution, which approached Gaussian after Box-Cox transformation. The reference limits estimated from small samples were highly variable. The closest estimates to the 1439-result reference interval for 27-result subsamples were obtained by both parametric and robust methods after Box-Cox transformation but were grossly erroneous in some cases. For small samples, it is recommended that all values be reported graphically in a dot plot or histogram and that estimates of the reference limits be compared using different methods.

  4. Thermal radiation transfer calculations in combustion fields using the SLW model coupled with a modified reference approach

    NASA Astrophysics Data System (ADS)

    Darbandi, Masoud; Abrar, Bagher

    2018-01-01

    The spectral-line weighted-sum-of-gray-gases (SLW) model is considered as a modern global model, which can be used in predicting the thermal radiation heat transfer within the combustion fields. The past SLW model users have mostly employed the reference approach to calculate the local values of gray gases' absorption coefficient. This classical reference approach assumes that the absorption spectra of gases at different thermodynamic conditions are scalable with the absorption spectrum of gas at a reference thermodynamic state in the domain. However, this assumption cannot be reasonable in combustion fields, where the gas temperature is very different from the reference temperature. Consequently, the results of SLW model incorporated with the classical reference approach, say the classical SLW method, are highly sensitive to the reference temperature magnitude in non-isothermal combustion fields. To lessen this sensitivity, the current work combines the SLW model with a modified reference approach, which is a particular one among the eight possible reference approach forms reported recently by Solovjov, et al. [DOI: 10.1016/j.jqsrt.2017.01.034, 2017]. The combination is called "modified SLW method". This work shows that the modified reference approach can provide more accurate total emissivity calculation than the classical reference approach if it is coupled with the SLW method. This would be particularly helpful for more accurate calculation of radiation transfer in highly non-isothermal combustion fields. To approve this, we use both the classical and modified SLW methods and calculate the radiation transfer in such fields. It is shown that the modified SLW method can almost eliminate the sensitivity of achieved results to the chosen reference temperature in treating highly non-isothermal combustion fields.

  5. Immunoturbidimetric quantification of serum immunoglobulin G concentration in foals.

    PubMed

    Bauer, J E; Brooks, T P

    1990-08-01

    Immunoturbidimetric determination of serum IgG concentration in foals was compared with the reference methods of single radial immunodiffusion and serum protein electrophoresis. High positive correlations were discovered when the technique was compared with either of these reference methods. The zinc sulfate turbidity test for serum IgG estimation was also evaluated. Although a positive correlation was discovered when the latter method was compared with reference methods, it was not as strong as the correlation between reference methods and the immunoturbidimetric method. The immunoturbidimetric method used in this study is specific and precise for equine serum IgG determination. It is rapid and, thus, is advantageous when timely evaluation of critically ill foals is necessary. The technique should be adaptable to various spectrophotometers and microcomputers for widespread application in veterinary medicine.

  6. Radioactive ion beam acceleration at MAFF

    NASA Astrophysics Data System (ADS)

    Pasini, M.; Kester, O.; Habs, D.; Groß, M.; Sieber, T.; Maier, H. J.; Assmann, W.; Krüken, R.; Faestermann, T.; Schempp, A.; Ratzinger, U.; Safvan, C. P.

    2004-12-01

    In April 2003, the German safety commission has given the final approval for the oper- ation of the high flux reactor FRM-II. This is an important step towards the development and installation of the Munich accelerator for fission fragments (MAFF), which will deliver highest intensities of neutron rich fission fragments. The acceleration chain of MAFF [1] consists of a charge breeder, which will deliver the ions with a mass to charge ratio of A/q ⩽ 6.3 irrespective of the mass range, and with a repetition rate of maximum 50 Hz. The LINAC operating at 10% duty cycle is composed of a 101.28 IH-RFQ, which will boost up the energy from 2.5 up to 300 keV/u, three IH-tanks that will deliver an energy of 5.4 MeV/u and 2 seven gap IH-resonators that are used to vary the final energy up to a maximum of 5.9 MeV/u. Currently beam dynamics revisions are in progress especially in the low energy section, since the experimental program has requested specific time structures of the beam for TOF experiments. The status of the beam dynamics studies as well as the status of the single components of the accelerator will be presented in this paper.

  7. Productivity and food value of Amaranthus cruentus under non-lethal salt stress

    NASA Technical Reports Server (NTRS)

    Macler, Bruce A.; Macelroy, Robert D.

    1989-01-01

    Experiments were carried out to analyze the effects of increasing salinity stress on growth, photosynthesis, and carbon allocation in the crop plant Amaranthus. Plants were germinated and grown in Hoagland's solution with NaCl concentrations of 0 to 1.0 percent. The limits of total salinity in the plant growth medium are investigated. For Amaranthus cruentus, germination, vegetative growth, flowering, seed development and yield were normal at salinities from 0 to 0.2 percent. Inhibition of these phases increased from o.2 to 0.4 percent salinity and was total above 0.5 percent with 1 percent salinity was lethal to all developmental phases. Onset of growth phases were not affected by salinity. Plants could not be adapted by gradually increasing salinity over days or weeks. Water uptake increased, while photosynthetic CO2 uptake decreased with increasing salinity on a dry weight basis during vegetative growth. Protein levels were unchanged with increasing salinity. Leaf starch levels were lower at salinities of 0.5 percent and above, while stem starch levels were not affected by these salinities. The evidence supports salt inhibition arising frm changes in primary biochemical processes rather than from effects on water relations. While not addressing the toxic effects of specific ions, it suggests that moderate salinity per se need not be a problem in space systems.

  8. Energy research with neutrons (ErwiN) and installation of a fast neutron powder diffraction option at the MLZ, Germany1

    PubMed Central

    Mühlbauer, Martin J.

    2018-01-01

    The need for rapid data collection and studies of small sample volumes in the range of cubic millimetres are the main driving forces for the concept of a new high-throughput monochromatic diffraction instrument at the Heinz Maier-Leibnitz Zentrum (MLZ), Germany. A large region of reciprocal space will be accessed by a detector with sufficient dynamic range and microsecond time resolution, while allowing for a variety of complementary sample environments. The medium-resolution neutron powder diffraction option for ‘energy research with neutrons’ (ErwiN) at the high-flux FRM II neutron source at the MLZ is foreseen to meet future demand. ErwiN will address studies of energy-related systems and materials with respect to their structure and uniformity by means of bulk and spatially resolved neutron powder diffraction. A set of experimental options will be implemented, enabling time-resolved studies, rapid parametric measurements as a function of external parameters and studies of small samples using an adapted radial collimator. The proposed powder diffraction option ErwiN will bridge the gap in functionality between the high-resolution powder diffractometer SPODI and the time-of-flight diffractometers POWTEX and SAPHiR at the MLZ. PMID:29896055

  9. Attenuated Virulence and Genomic Reductive Evolution in the Entomopathogenic Bacterial Symbiont Species, Xenorhabdus poinarii

    PubMed Central

    Ogier, Jean-Claude; Pagès, Sylvie; Bisch, Gaëlle; Chiapello, Hélène; Médigue, Claudine; Rouy, Zoé; Teyssier, Corinne; Vincent, Stéphanie; Tailliez, Patrick; Givaudan, Alain; Gaudriault, Sophie

    2014-01-01

    Bacteria of the genus Xenorhabdus are symbionts of soil entomopathogenic nematodes of the genus Steinernema. This symbiotic association constitutes an insecticidal complex active against a wide range of insect pests. Unlike other Xenorhabdus species, Xenorhabdus poinarii is avirulent when injected into insects in the absence of its nematode host. We sequenced the genome of the X. poinarii strain G6 and the closely related but virulent X. doucetiae strain FRM16. G6 had a smaller genome (500–700 kb smaller) than virulent Xenorhabdus strains and lacked genes encoding potential virulence factors (hemolysins, type 5 secretion systems, enzymes involved in the synthesis of secondary metabolites, and toxin–antitoxin systems). The genomes of all the X. poinarii strains analyzed here had a similar small size. We did not observe the accumulation of pseudogenes, insertion sequences or decrease in coding density usually seen as a sign of genomic erosion driven by genetic drift in host-adapted bacteria. Instead, genome reduction of X. poinarii seems to have been mediated by the excision of genomic blocks from the flexible genome, as reported for the genomes of attenuated free pathogenic bacteria and some facultative mutualistic bacteria growing exclusively within hosts. This evolutionary pathway probably reflects the adaptation of X. poinarii to specific host. PMID:24904010

  10. Online SEOP polarization of Large Area Neutron Spin Filters

    NASA Astrophysics Data System (ADS)

    Babcock, Earl; Salhi, Zahir; Ioffe, Alexander

    2015-04-01

    The Juelich Center for neutron Science has a program to use SEOP polarized 3He Neutron Spin Filters (3He NSF) on many neutron scattering instruments. The main applications are for polarization analysis of the scattered beam. As such, the devices must operate in close proximity to the neutron sample and sample environment which can include complicated cryostats, humidity and pressure cells, and high field magnets. Thus we have developed novel magnetic cavities to house the 3He NSF cells which allow for simultaneous optical pumping on the instruments. Further we continually develop and redevelop the laser sources which must be relatively narrow band and have long term (i.e. months) stability and robust operation. The first fully operational polarizer has been used continuously for over 2, 60-day reactor cycles at the FRM2. This device uses a 12.5 cm I.D. 3He cell, and has a 3He storage lifetime, including the cells lifetime, in excess of 200 hours with the cell about 60 cm from the sample position inside a 1.2 T electromagnet, and has achieved over 75% 3He polarisation when fully optimized. This talk will describe the magnetic cavities, and laser sources as well as provide a description of the completed 3He polarizer devices.

  11. The Kjeldahl method as a primary reference procedure for total protein in certified reference materials used in clinical chemistry. II. Selection of direct Kjeldahl analysis and its preliminary performance parameters.

    PubMed

    Vinklárková, Bára; Chromý, Vratislav; Šprongl, Luděk; Bittová, Miroslava; Rikanová, Milena; Ohnútková, Ivana; Žaludová, Lenka

    2015-01-01

    To select a Kjeldahl procedure suitable for the determination of total protein in reference materials used in laboratory medicine, we reviewed in our previous article Kjeldahl methods adopted by clinical chemistry and found an indirect two-step analysis by total Kjeldahl nitrogen corrected for its nonprotein nitrogen and a direct analysis made on isolated protein precipitates. In this article, we compare both procedures on various reference materials. An indirect Kjeldahl method gave falsely lower results than a direct analysis. Preliminary performance parameters qualify the direct Kjeldahl analysis as a suitable primary reference procedure for the certification of total protein in reference laboratories.

  12. Reference surfaces for bridge scour depths

    USGS Publications Warehouse

    Landers, Mark N.; Mueller, David S.; ,

    1993-01-01

    Depth of scour is measured as the vertical distance between scoured channel geometry and a measurement reference surface. A scour depth measurement can have a wide range depending on the method used to establish the reference surface. A consistent method to establish reference surfaces for bridge scour measurements is needed to facilitate transferability of scour data an scour analyses. This paper describes and evaluates techniques for establishing reference surfaces from which local and contraction scour are measured.

  13. Indirect methods for reference interval determination - review and recommendations.

    PubMed

    Jones, Graham R D; Haeckel, Rainer; Loh, Tze Ping; Sikaris, Ken; Streichert, Thomas; Katayev, Alex; Barth, Julian H; Ozarda, Yesim

    2018-04-19

    Reference intervals are a vital part of the information supplied by clinical laboratories to support interpretation of numerical pathology results such as are produced in clinical chemistry and hematology laboratories. The traditional method for establishing reference intervals, known as the direct approach, is based on collecting samples from members of a preselected reference population, making the measurements and then determining the intervals. An alternative approach is to perform analysis of results generated as part of routine pathology testing and using appropriate statistical techniques to determine reference intervals. This is known as the indirect approach. This paper from a working group of the International Federation of Clinical Chemistry (IFCC) Committee on Reference Intervals and Decision Limits (C-RIDL) aims to summarize current thinking on indirect approaches to reference intervals. The indirect approach has some major potential advantages compared with direct methods. The processes are faster, cheaper and do not involve patient inconvenience, discomfort or the risks associated with generating new patient health information. Indirect methods also use the same preanalytical and analytical techniques used for patient management and can provide very large numbers for assessment. Limitations to the indirect methods include possible effects of diseased subpopulations on the derived interval. The IFCC C-RIDL aims to encourage the use of indirect methods to establish and verify reference intervals, to promote publication of such intervals with clear explanation of the process used and also to support the development of improved statistical techniques for these studies.

  14. A comparative uncertainty study of the calibration of macrolide antibiotic reference standards using quantitative nuclear magnetic resonance and mass balance methods.

    PubMed

    Liu, Shu-Yu; Hu, Chang-Qin

    2007-10-17

    This study introduces the general method of quantitative nuclear magnetic resonance (qNMR) for the calibration of reference standards of macrolide antibiotics. Several qNMR experimental conditions were optimized including delay, which is an important parameter of quantification. Three kinds of macrolide antibiotics were used to validate the accuracy of the qNMR method by comparison with the results obtained by the high performance liquid chromatography (HPLC) method. The purities of five common reference standards of macrolide antibiotics were measured by the 1H qNMR method and the mass balance method, respectively. The analysis results of the two methods were compared. The qNMR is quick and simple to use. In a new medicine research and development process, qNMR provides a new and reliable method for purity analysis of the reference standard.

  15. Comparison of analytical and predictive methods for water, protein, fat, sugar, and gross energy in marine mammal milk.

    PubMed

    Oftedal, O T; Eisert, R; Barrell, G K

    2014-01-01

    Mammalian milks may differ greatly in composition from cow milk, and these differences may affect the performance of analytical methods. High-fat, high-protein milks with a preponderance of oligosaccharides, such as those produced by many marine mammals, present a particular challenge. We compared the performance of several methods against reference procedures using Weddell seal (Leptonychotes weddellii) milk of highly varied composition (by reference methods: 27-63% water, 24-62% fat, 8-12% crude protein, 0.5-1.8% sugar). A microdrying step preparatory to carbon-hydrogen-nitrogen (CHN) gas analysis slightly underestimated water content and had a higher repeatability relative standard deviation (RSDr) than did reference oven drying at 100°C. Compared with a reference macro-Kjeldahl protein procedure, the CHN (or Dumas) combustion method had a somewhat higher RSDr (1.56 vs. 0.60%) but correlation between methods was high (0.992), means were not different (CHN: 17.2±0.46% dry matter basis; Kjeldahl 17.3±0.49% dry matter basis), there were no significant proportional or constant errors, and predictive performance was high. A carbon stoichiometric procedure based on CHN analysis failed to adequately predict fat (reference: Röse-Gottlieb method) or total sugar (reference: phenol-sulfuric acid method). Gross energy content, calculated from energetic factors and results from reference methods for fat, protein, and total sugar, accurately predicted gross energy as measured by bomb calorimetry. We conclude that the CHN (Dumas) combustion method and calculation of gross energy are acceptable analytical approaches for marine mammal milk, but fat and sugar require separate analysis by appropriate analytic methods and cannot be adequately estimated by carbon stoichiometry. Some other alternative methods-low-temperature drying for water determination; Bradford, Lowry, and biuret methods for protein; the Folch and the Bligh and Dyer methods for fat; and enzymatic and reducing sugar methods for total sugar-appear likely to produce substantial error in marine mammal milks. It is important that alternative analytical methods be properly validated against a reference method before being used, especially for mammalian milks that differ greatly from cow milk in analyte characteristics and concentrations. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  16. Different equation-of-motion coupled cluster methods with different reference functions: The formyl radical

    NASA Astrophysics Data System (ADS)

    Kuś, Tomasz; Bartlett, Rodney J.

    2008-09-01

    The doublet and quartet excited states of the formyl radical have been studied by the equation-of-motion (EOM) coupled cluster (CC) method. The Sz spin-conserving singles and doubles (EOM-EE-CCSD) and singles, doubles, and triples (EOM-EE-CCSDT) approaches, as well as the spin-flipped singles and doubles (EOM-SF-CCSD) method have been applied, subject to unrestricted Hartree-Fock (HF), restricted open-shell HF, and quasirestricted HF references. The structural parameters, vertical and adiabatic excitation energies, and harmonic vibrational frequencies have been calculated. The issue of the reference function choice for the spin-flipped (SF) method and its impact on the results has been discussed using the experimental data and theoretical results available. The results show that if the appropriate reference function is chosen so that target states differ from the reference by only single excitations, then EOM-EE-CCSD and EOM-SF-CCSD methods give a very good description of the excited states. For the states that have a non-negligible contribution of the doubly excited configurations one is able to use the SF method with such a reference function, that in most cases the performance of the EOM-SF-CCSD method is better than that of the EOM-EE-CCSD approach.

  17. Identification of tensile strength properties of abaca fiber by weakest-linkage approach-statistic property of fiber diameter

    NASA Astrophysics Data System (ADS)

    Suardi; Homma, H.; Abubakar

    2018-02-01

    Fiber reinforced plastics or metals (FRPor FRM) are usually ecological materials, because their specific strength defined as the strengthperunit mass is much larger than metal, and weight ofmachines and structuresfor transport made ofFRP can be significantly reduced so that the consumption of fossil fuel scan be saved to result in tremendous reduction of CO2emissions. However, when we consider life cycle assessment (LCA) of synthetic fibers like carbon fiber and glass fiber, we can recognize much CO2 emission in production of these fibers. Therefore, more ecological reinforcement fibers must be developed. For this end, we should utilization cellulose fibers derived from plant tissue structure as an alternative fibers for synthetic fibers, which are considered as carbon neutral materials, and natural degraded material. This study selectsabaca fiber, which is a natural fiber and is abundant in Indonesia, but its usagehas not been optimized for engineering material. The purpose of this study is to identify the mechanical strength of a single abaca fiber by statistical approach. First, weakest link theory and Weibull theory are used to discuss experimental data. 90 specimens of almost identical geometry and biological aspects are tested under tension. These data are analyzed by Weibull theory or other statistical theory. Final target is to look into optimal method to reduce scatter ratio, ratio of standard deviation to mean value, of less than 0.1, which is the level of metallic materials. If we can reduce scatter ration to such level, we can design machines and structures using abaca fiber in the same way as carbon fibers or glass fibers. Summary of Diameter Measurement the all mean value is 0.1 and standardeviasi. The t-Test showed that mean value of each part is estimated as sampling from group with the same mean value, at confidence level of 99%.

  18. Romer Labs RapidChek®Listeria monocytogenes Test System for the Detection of L. monocytogenes on Selected Foods and Environmental Surfaces.

    PubMed

    Juck, Gregory; Gonzalez, Verapaz; Allen, Ann-Christine Olsson; Sutzko, Meredith; Seward, Kody; Muldoon, Mark T

    2018-04-27

    The Romer Labs RapidChek ® Listeria monocytogenes test system (Performance Tested Method ℠ 011805) was validated against the U.S. Department of Agriculture-Food Safety and Inspection Service Microbiology Laboratory Guidebook (USDA-FSIS/MLG), U.S. Food and Drug Association Bacteriological Analytical Manual (FDA/BAM), and AOAC Official Methods of Analysis ℠ (AOAC/OMA) cultural reference methods for the detection of L. monocytogenes on selected foods including hot dogs, frozen cooked breaded chicken, frozen cooked shrimp, cured ham, and ice cream, and environmental surfaces including stainless steel and plastic in an unpaired study design. The RapidChek method uses a proprietary enrichment media system, a 44-48 h enrichment at 30 ± 1°C, and detects L. monocytogenes on an immunochromatographic lateral flow device within 10 min. Different L. monocytogenes strains were used to spike each of the matrixes. Samples were confirmed based on the reference method confirmations and an alternate confirmation method. A total of 140 low-level spiked samples were tested by the RapidChek method after enrichment for 44-48 h in parallel with the cultural reference method. There were 88 RapidChek presumptive positives. One of the presumptive positives was not confirmed culturally. Additionally, one of the culturally confirmed samples did not exhibit a presumptive positive. No difference between the alternate confirmation method and reference confirmation method was observed. The respective cultural reference methods (USDA-FSIS/MLG, FDA/BAM, and AOAC/OMA) produced a total of 63 confirmed positive results. Nonspiked samples from all foods were reported as negative for L. monocytogenes by all methods. Probability of detection analysis demonstrated no significant differences in the number of positive samples detected by the RapidChek method and the respective cultural reference method.

  19. Reference interval estimation: Methodological comparison using extensive simulations and empirical data.

    PubMed

    Daly, Caitlin H; Higgins, Victoria; Adeli, Khosrow; Grey, Vijay L; Hamid, Jemila S

    2017-12-01

    To statistically compare and evaluate commonly used methods of estimating reference intervals and to determine which method is best based on characteristics of the distribution of various data sets. Three approaches for estimating reference intervals, i.e. parametric, non-parametric, and robust, were compared with simulated Gaussian and non-Gaussian data. The hierarchy of the performances of each method was examined based on bias and measures of precision. The findings of the simulation study were illustrated through real data sets. In all Gaussian scenarios, the parametric approach provided the least biased and most precise estimates. In non-Gaussian scenarios, no single method provided the least biased and most precise estimates for both limits of a reference interval across all sample sizes, although the non-parametric approach performed the best for most scenarios. The hierarchy of the performances of the three methods was only impacted by sample size and skewness. Differences between reference interval estimates established by the three methods were inflated by variability. Whenever possible, laboratories should attempt to transform data to a Gaussian distribution and use the parametric approach to obtain the most optimal reference intervals. When this is not possible, laboratories should consider sample size and skewness as factors in their choice of reference interval estimation method. The consequences of false positives or false negatives may also serve as factors in this decision. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  20. The Stayhealthy bioelectrical impedance analyzer predicts body fat in children and adults.

    PubMed

    Erceg, David N; Dieli-Conwright, Christina M; Rossuello, Amerigo E; Jensky, Nicole E; Sun, Stephanie; Schroeder, E Todd

    2010-05-01

    Bioelectrical impedance analysis (BIA) is a time-efficient and cost-effective method for estimating body composition. We hypothesized that there would be no significant difference between the Stayhealthy BC1 BIA and the selected reference methods when determining body composition. Thus, the purpose of the present study was to determine the validity of estimating percent body fat (%BF) using the Stayhealthy BIA with its most recently updated algorithms compared to the reference methods of dual-energy x-ray absorptiometry for adults and hydrostatic weighing for children. We measured %BF in 245 adults aged 18 to 80 years and 115 children aged 10 to 17 years. Body fat by BIA was determined using a single 50 kHz frequency handheld impedance device and proprietary software. Agreement between BIA and reference methods was assessed by Bland and Altman plots. Bland and Altman analysis for men, women, and children revealed good agreement between the reference methods and BIA. There was no significant difference by t tests between mean %BF by BIA for men, women, or children when compared to the respective reference method. Significant correlation values between BIA, and reference methods for all men, women, and children were 0.85, 0.88, and 0.79, respectively. Reliability (test-retest) was assessed by intraclass correlation coefficient and coefficient of variation. Intraclass correlation coefficient values were greater than 0.99 (P < .001) for men, women, and children with coefficient of variation values 3.3%, 1.8%, and 1.7%, respectively. The Stayhealthy BIA device demonstrated good agreement between reference methods using Bland and Altman analyses. Copyright 2010 Elsevier Inc. All rights reserved.

  1. Adaptive optimization of reference intensity for optical coherence imaging using galvanometric mirror tilting method

    NASA Astrophysics Data System (ADS)

    Kim, Ji-hyun; Han, Jae-Ho; Jeong, Jichai

    2015-09-01

    Integration time and reference intensity are important factors for achieving high signal-to-noise ratio (SNR) and sensitivity in optical coherence tomography (OCT). In this context, we present an adaptive optimization method of reference intensity for OCT setup. The reference intensity is automatically controlled by tilting a beam position using a Galvanometric scanning mirror system. Before sample scanning, the OCT system acquires two dimensional intensity map with normalized intensity and variables in color spaces using false-color mapping. Then, the system increases or decreases reference intensity following the map data for optimization with a given algorithm. In our experiments, the proposed method successfully corrected the reference intensity with maintaining spectral shape, enabled to change integration time without manual calibration of the reference intensity, and prevented image degradation due to over-saturation and insufficient reference intensity. Also, SNR and sensitivity could be improved by increasing integration time with automatic adjustment of the reference intensity. We believe that our findings can significantly aid in the optimization of SNR and sensitivity for optical coherence tomography systems.

  2. 40 CFR 75.22 - Reference test methods.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... appendix A to part 60 of this chapter, except for Methods 2B and 2E, are the reference methods for... provided in appendix A to part 60 of this chapter, except for Methods 2B and 2E, for determining volumetric...

  3. 40 CFR 75.22 - Reference test methods.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... appendix A to part 60 of this chapter, except for Methods 2B and 2E, are the reference methods for... provided in appendix A to part 60 of this chapter, except for Methods 2B and 2E, for determining volumetric...

  4. Determination of the purity of pharmaceutical reference materials by 1H NMR using the standardless PULCON methodology.

    PubMed

    Monakhova, Yulia B; Kohl-Himmelseher, Matthias; Kuballa, Thomas; Lachenmeier, Dirk W

    2014-11-01

    A fast and reliable nuclear magnetic resonance spectroscopic method for quantitative determination (qNMR) of targeted molecules in reference materials has been established using the ERETIC2 methodology (electronic reference to access in vivo concentrations) based on the PULCON principle (pulse length based concentration determination). The developed approach was validated for the analysis of pharmaceutical samples in the context of official medicines control, including ibandronic acid, amantadine, ambroxol and lercanidipine. The PULCON recoveries were above 94.3% and coefficients of variation (CVs) obtained by quantification of different targeted resonances ranged between 0.7% and 2.8%, demonstrating that the qNMR method is a precise tool for rapid quantification (approximately 15min) of reference materials and medicinal products. Generally, the values were within specification (certified values) provided by the manufactures. The results were in agreement with NMR quantification using an internal standard and validated reference HPLC analysis. The PULCON method was found to be a practical alternative with competitive precision and accuracy to the classical internal reference method and it proved to be applicable to different solvent conditions. The method can be recommended for routine use in medicines control laboratories, especially when the availability and costs of reference compounds are problematic. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. 40 CFR 60.547 - Test methods and procedures.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... materials. In the event of dispute, Method 24 shall be the reference method. For Method 24, the cement or... sample will be representative of the material as applied in the affected facility. (2) Method 25 as the... by the Administrator. (3) Method 2, 2A, 2C, or 2D, as appropriate, as the reference method for...

  6. 40 CFR 60.547 - Test methods and procedures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... materials. In the event of dispute, Method 24 shall be the reference method. For Method 24, the cement or... sample will be representative of the material as applied in the affected facility. (2) Method 25 as the... by the Administrator. (3) Method 2, 2A, 2C, or 2D, as appropriate, as the reference method for...

  7. 40 CFR 60.547 - Test methods and procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... materials. In the event of dispute, Method 24 shall be the reference method. For Method 24, the cement or... sample will be representative of the material as applied in the affected facility. (2) Method 25 as the... by the Administrator. (3) Method 2, 2A, 2C, or 2D, as appropriate, as the reference method for...

  8. 40 CFR 63.805 - Performance test methods.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... alternative method for determining the VHAP content of the coating. In the event of any inconsistency between... Collection of Coating and Ink Samples for VOC Content Analysis by Reference Method 24 and Reference Method... (see § 63.801); (iii) Use any alternative protocol and test method provided they meet either the...

  9. Some possible reference materials for fire toxicity tests

    NASA Technical Reports Server (NTRS)

    Hilado, C. J.; Solis, A. N.

    1977-01-01

    Suitable reference materials need to be selected in order to standardize any test method. The evaluation of cotton, polyethylene, polyether sulfone, polycarbonate, polystyrene, and polyurethane flexible and rigid foams as possible reference materials for the University of San Francisco/NASA toxicity screening test method is discussed.

  10. [Selection of reference genes of Siraitia grosvenorii by real-time PCR].

    PubMed

    Tu, Dong-ping; Mo, Chang-ming; Ma, Xiao-jun; Zhao, Huan; Tang, Qi; Huang, Jie; Pan, Li-mei; Wei, Rong-chang

    2015-01-01

    Siraitia grosvenorii is a traditional Chinese medicine also as edible food. This study selected six candidate reference genes by real-time quantitative PCR, the expression stability of the candidate reference genes in the different samples was analyzed by using the software and methods of geNorm, NormFinder, BestKeeper, Delta CT method and RefFinder, reference genes for S. grosvenorii were selected for the first time. The results showed that 18SrRNA expressed most stable in all samples, was the best reference gene in the genetic analysis. The study has a guiding role for the analysis of gene expression using qRT-PCR methods, providing a suitable reference genes to ensure the results in the study on differential expressed gene in synthesis and biological pathways, also other genes of S. grosvenorii.

  11. A candidate reference method for serum potassium measurement by inductively coupled plasma mass spectrometry.

    PubMed

    Yan, Ying; Han, Bingqing; Zeng, Jie; Zhou, Weiyan; Zhang, Tianjiao; Zhang, Jiangtao; Chen, Wenxiang; Zhang, Chuanbao

    2017-08-28

    Potassium is an important serum ion that is frequently assayed in clinical laboratories. Quality assurance requires reference methods; thus, the establishment of a candidate reference method for serum potassium measurements is important. An inductively coupled plasma mass spectrometry (ICP-MS) method was developed. Serum samples were gravimetrically spiked with an aluminum internal standard, digested with 69% ultrapure nitric acid, and diluted to the required concentration. The 39K/27Al ratios were measured by ICP-MS in hydrogen mode. The method was calibrated using 5% nitric acid matrix calibrators, and the calibration function was established using the bracketing method. The correlation coefficients between the measured 39K/27Al ratios and the analyte concentration ratios were >0.9999. The coefficients of variation were 0.40%, 0.68%, and 0.22% for the three serum samples, and the analytical recovery was 99.8%. The accuracy of the measurement was also verified by measuring certified reference materials, SRM909b and SRM956b. Comparison with the ion selective electrode routine method and international inter-laboratory comparisons gave satisfied results. The new ICP-MS method is specific, precise, simple, and low-cost, and it may be used as a candidate reference method for standardizing serum potassium measurements.

  12. 1 CFR 21.21 - General requirements: References.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 1 General Provisions 1 2010-01-01 2010-01-01 false General requirements: References. 21.21 Section... to test methods or consensus standards produced by a Federal agency that have replaced or preempted private or voluntary test methods or consensus standards in a subject matter area. (5) The reference is to...

  13. 40 CFR 91.6 - Reference materials.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... EMISSIONS FROM MARINE SPARK-IGNITION ENGINES General § 91.6 Reference materials. (a) Incorporation by... the Research Method Appendix A to Subpart D. ASTM D2700-92: Standard Test Method for Knock... 40 CFR part 91 reference SAE J1228/ISO 8665 November 1991 Small Craft-Marine Propulsion Engine and...

  14. 40 CFR 91.6 - Reference materials.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... EMISSIONS FROM MARINE SPARK-IGNITION ENGINES General § 91.6 Reference materials. (a) Incorporation by... the Research Method Appendix A to Subpart D. ASTM D2700-92: Standard Test Method for Knock... 40 CFR part 91 reference SAE J1228/ISO 8665 November 1991 Small Craft-Marine Propulsion Engine and...

  15. 40 CFR 91.6 - Reference materials.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... EMISSIONS FROM MARINE SPARK-IGNITION ENGINES General § 91.6 Reference materials. (a) Incorporation by... the Research Method Appendix A to Subpart D. ASTM D2700-92: Standard Test Method for Knock... 40 CFR part 91 reference SAE J1228/ISO 8665 November 1991 Small Craft-Marine Propulsion Engine and...

  16. Transmit-reference methods in software defined radio platforms for communication in harsh propagation environments and systems thereof

    DOEpatents

    Dowla, Farid U; Nekoogar, Faranak

    2015-03-03

    A method for adaptive Radio Frequency (RF) jamming according to one embodiment includes dynamically monitoring a RF spectrum; detecting any undesired signals in real time from the RF spectrum; and sending a directional countermeasure signal to jam the undesired signals. A method for adaptive Radio Frequency (RF) communications according to another embodiment includes transmitting a data pulse in a RF spectrum; and transmitting a reference pulse separated by a predetermined period of time from the data pulse; wherein the data pulse is modulated with data, wherein the reference pulse is unmodulated. A method for adaptive Radio Frequency (RF) communications according to yet another embodiment includes receiving a data pulse in a RF spectrum; and receiving a reference pulse separated in time from the data pulse, wherein the data pulse is modulated with data, wherein the reference pulse is unmodulated; and demodulating the pulses.

  17. Transmit-reference methods in software defined radio platforms for communication in harsh propagation environments and systems thereof

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dowla, Farid; Nekoogar, Faranak

    A method for adaptive Radio Frequency (RF) jamming according to one embodiment includes dynamically monitoring a RF spectrum; detecting any undesired signals in real time from the RF spectrum; and sending a directional countermeasure signal to jam the undesired signals. A method for adaptive Radio Frequency (RF) communications according to another embodiment includes transmitting a data pulse in a RF spectrum; and transmitting a reference pulse separated by a predetermined period of time from the data pulse; wherein the data pulse is modulated with data, wherein the reference pulse is unmodulated. A method for adaptive Radio Frequency (RF) communications accordingmore » to yet another embodiment includes receiving a data pulse in a RF spectrum; and receiving a reference pulse separated in time from the data pulse, wherein the data pulse is modulated with data, wherein the reference pulse is unmodulated; and demodulating the pulses.« less

  18. Coordinates and intervals in graph-based reference genomes.

    PubMed

    Rand, Knut D; Grytten, Ivar; Nederbragt, Alexander J; Storvik, Geir O; Glad, Ingrid K; Sandve, Geir K

    2017-05-18

    It has been proposed that future reference genomes should be graph structures in order to better represent the sequence diversity present in a species. However, there is currently no standard method to represent genomic intervals, such as the positions of genes or transcription factor binding sites, on graph-based reference genomes. We formalize offset-based coordinate systems on graph-based reference genomes and introduce methods for representing intervals on these reference structures. We show the advantage of our methods by representing genes on a graph-based representation of the newest assembly of the human genome (GRCh38) and its alternative loci for regions that are highly variable. More complex reference genomes, containing alternative loci, require methods to represent genomic data on these structures. Our proposed notation for genomic intervals makes it possible to fully utilize the alternative loci of the GRCh38 assembly and potential future graph-based reference genomes. We have made a Python package for representing such intervals on offset-based coordinate systems, available at https://github.com/uio-cels/offsetbasedgraph . An interactive web-tool using this Python package to visualize genes on a graph created from GRCh38 is available at https://github.com/uio-cels/genomicgraphcoords .

  19. 40 CFR - Unknown Title

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 6 2014-07-01 2014-07-01 false Section Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) AMBIENT AIR MONITORING REFERENCE AND EQUIVALENT METHODS Procedures for Determining Comparability Between Candidate Methods and Reference Method...

  20. 75 FR 45627 - Office of Research and Development; Ambient Air Monitoring Reference and Equivalent Methods...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-03

    ... Monitoring Reference and Equivalent Methods: Designation of One New Equivalent Method AGENCY: Environmental Protection Agency. ACTION: Notice of the designation of one new equivalent method for monitoring ambient air... accordance with 40 CFR part 53, one new equivalent method for measuring concentrations of lead (Pb) in total...

  1. 76 FR 62402 - Office of Research and Development; Ambient Air Monitoring Reference and Equivalent Methods...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-07

    ... Monitoring Reference and Equivalent Methods; Designation of One New Equivalent Method AGENCY: Environmental Protection Agency. ACTION: Notice of the designation of one new equivalent method for monitoring ambient air... accordance with 40 CFR Part 53, one new equivalent method for measuring concentrations of ozone (O 3 ) in the...

  2. 75 FR 51039 - Office of Research and Development; Ambient Air Monitoring Reference and Equivalent Methods...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-18

    ... Monitoring Reference and Equivalent Methods: Designation of Two New Equivalent Methods AGENCY: Environmental Protection Agency. ACTION: Notice of the designation of two new equivalent methods for monitoring ambient air... accordance with 40 CFR Part 53, two new equivalent methods for measuring concentrations of PM 10 and sulfur...

  3. 75 FR 22126 - Office of Research and Development; Ambient Air Monitoring Reference and Equivalent Methods...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-27

    ... Monitoring Reference and Equivalent Methods: Designation of One New Equivalent Method AGENCY: Environmental Protection Agency. ACTION: Notice of the designation of one new equivalent method for monitoring ambient air... accordance with 40 CFR Part 53, one new equivalent method for measuring concentrations of ozone (O 3 ) in the...

  4. 75 FR 30022 - Office of Research and Development; Ambient Air Monitoring Reference and Equivalent Methods...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-28

    ... Monitoring Reference and Equivalent Methods: Designation of One New Equivalent Method AGENCY: Environmental Protection Agency. ACTION: Notice of the designation of one new equivalent method for monitoring ambient air... accordance with 40 CFR Part 53, one new equivalent method for measuring concentrations of lead (Pb) in total...

  5. 75 FR 9894 - Office of Research and Development; Ambient Air Monitoring Reference and Equivalent Methods...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-04

    ... Monitoring Reference and Equivalent Methods: Designation of One New Equivalent Method AGENCY: Environmental Protection Agency. ACTION: Notice of the designation of one new equivalent method for monitoring ambient air... accordance with 40 CFR part 53, one new equivalent method for measuring concentrations of lead (Pb) in total...

  6. Improved motion correction in PROPELLER by using grouped blades as reference.

    PubMed

    Liu, Zhe; Zhang, Zhe; Ying, Kui; Yuan, Chun; Guo, Hua

    2014-03-01

    To develop a robust reference generation method for improving PROPELLER (Periodically Rotated Overlapping ParallEL Lines with Enhanced Reconstruction) reconstruction. A new reference generation method, grouped-blade reference (GBR), is proposed for calculating rotation angle and translation shift in PROPELLER. Instead of using a single-blade reference (SBR) or combined-blade reference (CBR), our method classifies blades by their relative correlations and groups similar blades together as the reference to prevent inconsistent data from interfering the correction process. Numerical simulations and in vivo experiments were used to evaluate the performance of GBR for PROPELLER, which was further compared with SBR and CBR in terms of error level and computation cost. Both simulation and in vivo experiments demonstrate that GBR-based PROPELLER provides better correction for random motion or bipolar motion comparing with SBR or CBR. It not only produces images with lower error level but also needs less iteration steps to converge. A grouped-blade for reference selection was investigated for PROPELLER MRI. It helps to improve the accuracy and robustness of motion correction for various motion patterns. Copyright © 2013 Wiley Periodicals, Inc.

  7. Effect of genotyped cows in the reference population on the genomic evaluation of Holstein cattle.

    PubMed

    Uemoto, Y; Osawa, T; Saburi, J

    2017-03-01

    This study evaluated the dependence of reliability and prediction bias on the prediction method, the contribution of including animals (bulls or cows), and the genetic relatedness, when including genotyped cows in the progeny-tested bull reference population. We performed genomic evaluation using a Japanese Holstein population, and assessed the accuracy of genomic enhanced breeding value (GEBV) for three production traits and 13 linear conformation traits. A total of 4564 animals for production traits and 4172 animals for conformation traits were genotyped using Illumina BovineSNP50 array. Single- and multi-step methods were compared for predicting GEBV in genotyped bull-only and genotyped bull-cow reference populations. No large differences in realized reliability and regression coefficient were found between the two reference populations; however, a slight difference was found between the two methods for production traits. The accuracy of GEBV determined by single-step method increased slightly when genotyped cows were included in the bull reference population, but decreased slightly by multi-step method. A validation study was used to evaluate the accuracy of GEBV when 800 additional genotyped bulls (POPbull) or cows (POPcow) were included in the base reference population composed of 2000 genotyped bulls. The realized reliabilities of POPbull were higher than those of POPcow for all traits. For the gain of realized reliability over the base reference population, the average ratios of POPbull gain to POPcow gain for production traits and conformation traits were 2.6 and 7.2, respectively, and the ratios depended on heritabilities of the traits. For regression coefficient, no large differences were found between the results for POPbull and POPcow. Another validation study was performed to investigate the effect of genetic relatedness between cows and bulls in the reference and test populations. The effect of genetic relationship among bulls in the reference population was also assessed. The results showed that it is important to account for relatedness among bulls in the reference population. Our studies indicate that the prediction method, the contribution ratio of including animals, and genetic relatedness could affect the prediction accuracy in genomic evaluation of Holstein cattle, when including genotyped cows in the reference population.

  8. Testing the causal theory of reference.

    PubMed

    Domaneschi, Filippo; Vignolo, Massimiliano; Di Paola, Simona

    2017-04-01

    Theories of reference are a crucial research topic in analytic philosophy. Since the publication of Kripke's Naming and Necessity, most philosophers have endorsed the causal/historical theory of reference. The goal of this paper is twofold: (i) to discuss a method for testing experimentally the causal theory of reference for proper names by investigating linguistic usage and (ii) to present the results from two experiments conducted with that method. Data collected in our experiments confirm the causal theory of reference for people proper names and for geographical proper names. A secondary but interesting result is that the semantic domain affects reference assignment: while with people proper names speakers tend to assign the semantic reference, with geographical proper names they are prompted to assign the speaker's reference. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. [Study on ethnic medicine quantitative reference herb,Tibetan medicine fruits of Capsicum frutescens as a case].

    PubMed

    Zan, Ke; Cui, Gan; Guo, Li-Nong; Ma, Shuang-Cheng; Zheng, Jian

    2018-05-01

    High price and difficult to get of reference substance have become obstacles to HPLC assay of ethnic medicine. A new method based on quantitative reference herb (QRH) was proposed. Specific chromatograms in fruits of Capsicum frutescens were employed to determine peak positions, and HPLC quantitative reference herb was prepared from fruits of C. frutescens. The content of capsaicin and dihydrocapsaicin in the quantitative control herb was determined by HPLC. Eleven batches of fruits of C. frutescens were analyzed with quantitative reference herb and reference substance respectively. The results showed no difference. The present method is feasible for quality control of ethnic medicines and quantitative reference herb is suitable to replace reference substances in assay. Copyright© by the Chinese Pharmaceutical Association.

  10. Comparison between the triglycerides standardization of routine methods used in Japan and the chromotropic acid reference measurement procedure used by the CDC Lipid Standardization Programme.

    PubMed

    Nakamura, Masakazu; Iso, Hiroyasu; Kitamura, Akihiko; Imano, Hironori; Noda, Hiroyuki; Kiyama, Masahiko; Sato, Shinichi; Yamagishi, Kazumasa; Nishimura, Kunihiro; Nakai, Michikazu; Vesper, Hubert W; Teramoto, Tamio; Miyamoto, Yoshihiro

    2016-11-01

    Background The US Centers for Disease Control and Prevention ensured adequate performance of the routine triglycerides methods used in Japan by a chromotropic acid reference measurement procedure used by the Centers for Disease Control and Prevention lipid standardization programme as a reference point. We examined standardized data to clarify the performance of routine triglycerides methods. Methods The two routine triglycerides methods were the fluorometric method of Kessler and Lederer and the enzymatic method. The methods were standardized using 495 Centers for Disease Control and Prevention reference pools with 98 different concentrations ranging between 0.37 and 5.15 mmol/L in 141 survey runs. The triglycerides criteria for laboratories which perform triglycerides analyses are used: accuracy, as bias ≤5% from the Centers for Disease Control and Prevention reference value and precision, as measured by CV, ≤5%. Results The correlation of the bias of both methods to the Centers for Disease Control and Prevention reference method was: y (%bias) = 0.516 × (Centers for Disease Control and Prevention reference value) -1.292 ( n = 495, R 2  = 0.018). Triglycerides bias at medical decision points of 1.13, 1.69 and 2.26 mmol/L was -0.71%, -0.42% and -0.13%, respectively. For the combined precision, the equation y (CV) = -0.398 × (triglycerides value) + 1.797 ( n = 495, R 2  = 0.081) was used. Precision was 1.35%, 1.12% and 0.90%, respectively. It was shown that triglycerides measurements at Osaka were stable for 36 years. Conclusions The epidemiologic laboratory in Japan met acceptable accuracy goals for 88.7% of all samples, and met acceptable precision goals for 97.8% of all samples measured through the Centers for Disease Control and Prevention lipid standardization programme and demonstrated stable results for an extended period of time.

  11. Comparison between the triglycerides standardization of routine methods used in Japan and the chromotropic acid reference measurement procedure used by the CDC Lipid Standardization Programme

    PubMed Central

    Nakamura, Masakazu; Iso, Hiroyasu; Kitamura, Akihiko; Imano, Hironori; Noda, Hiroyuki; Kiyama, Masahiko; Sato, Shinichi; Yamagishi, Kazumasa; Nishimura, Kunihiro; Nakai, Michikazu; Vesper, Hubert W; Teramoto, Tamio; Miyamoto, Yoshihiro

    2017-01-01

    Background The US Centers for Disease Control and Prevention ensured adequate performance of the routine triglycerides methods used in Japan by a chromotropic acid reference measurement procedure used by the Centers for Disease Control and Prevention lipid standardization programme as a reference point. We examined standardized data to clarify the performance of routine triglycerides methods. Methods The two routine triglycerides methods were the fluorometric method of Kessler and Lederer and the enzymatic method. The methods were standardized using 495 Centers for Disease Control and Prevention reference pools with 98 different concentrations ranging between 0.37 and 5.15 mmol/L in 141 survey runs. The triglycerides criteria for laboratories which perform triglycerides analyses are used: accuracy, as bias ≤5% from the Centers for Disease Control and Prevention reference value and precision, as measured by CV, ≤5%. Results The correlation of the bias of both methods to the Centers for Disease Control and Prevention reference method was: y (%bias) = 0.516 × (Centers for Disease Control and Prevention reference value) −1.292 (n = 495, R2 = 0.018). Triglycerides bias at medical decision points of 1.13, 1.69 and 2.26 mmol/L was −0.71%, −0.42% and −0.13%, respectively. For the combined precision, the equation y (CV) = −0.398 × (triglycerides value) + 1.797 (n = 495, R2 = 0.081) was used. Precision was 1.35%, 1.12% and 0.90%, respectively. It was shown that triglycerides measurements at Osaka were stable for 36 years. Conclusions The epidemiologic laboratory in Japan met acceptable accuracy goals for 88.7% of all samples, and met acceptable precision goals for 97.8% of all samples measured through the Centers for Disease Control and Prevention lipid standardization programme and demonstrated stable results for an extended period of time. PMID:26680645

  12. Method and apparatus for displaying information

    NASA Technical Reports Server (NTRS)

    Huang, Sui (Inventor); Eichler, Gabriel (Inventor); Ingber, Donald E. (Inventor)

    2010-01-01

    A method for displaying large amounts of information. The method includes the steps of forming a spatial layout of tiles each corresponding to a representative reference element; mapping observed elements onto the spatial layout of tiles of representative reference elements; assigning a respective value to each respective tile of the spatial layout of the representative elements; and displaying an image of the spatial layout of tiles of representative elements. Each tile includes atomic attributes of representative elements. The invention also relates to an apparatus for displaying large amounts of information. The apparatus includes a tiler forming a spatial layout of tiles, each corresponding to a representative reference element; a comparator mapping observed elements onto said spatial layout of tiles of representative reference elements; an assigner assigning a respective value to each respective tile of said spatial layout of representative reference elements; and a display displaying an image of the spatial layout of tiles of representative reference elements.

  13. Method and apparatus for large motor control

    DOEpatents

    Rose, Chris R [Santa Fe, NM; Nelson, Ronald O [White Rock, NM

    2003-08-12

    Apparatus and method for providing digital signal processing method for controlling the speed and phase of a motor involves inputting a reference signal having a frequency and relative phase indicative of a time based signal; modifying the reference signal to introduce a slew-rate limited portion of each cycle of the reference signal; inputting a feedback signal having a frequency and relative phase indicative of the operation of said motor; modifying the feedback signal to introduce a slew-rate limited portion of each cycle of the feedback signal; analyzing the modified reference signal and the modified feedback signal to determine the frequency of the modified reference signal and of the modified feedback signal and said relative phase between said modified reference signal and said modified feedback signal; and outputting control signals to the motor for adjusting said speed and phase of the motor based on the frequency determination and determination of the relative phase.

  14. Reference-based source separation method for identification of brain regions involved in a reference state from intracerebral EEG

    PubMed Central

    Samadi, Samareh; Amini, Ladan; Cosandier-Rimélé, Delphine; Soltanian-Zadeh, Hamid; Jutten, Christian

    2013-01-01

    In this paper, we present a fast method to extract the sources related to interictal epileptiform state. The method is based on general eigenvalue decomposition using two correlation matrices during: 1) periods including interictal epileptiform discharges (IED) as a reference activation model and 2) periods excluding IEDs or abnormal physiological signals as background activity. After extracting the most similar sources to the reference or IED state, IED regions are estimated by using multiobjective optimization. The method is evaluated using both realistic simulated data and actual intracerebral electroencephalography recordings of patients suffering from focal epilepsy. These patients are seizure-free after the resective surgery. Quantitative comparisons of the proposed IED regions with the visually inspected ictal onset zones by the epileptologist and another method of identification of IED regions reveal good performance. PMID:23428609

  15. [The water content reference material of water saturated octanol].

    PubMed

    Wang, Haifeng; Ma, Kang; Zhang, Wei; Li, Zhanyuan

    2011-03-01

    The national standards of biofuels specify the technique specification and analytical methods. A water content certified reference material based on the water saturated octanol was developed in order to satisfy the needs of the instrument calibration and the methods validation, assure the accuracy and consistency of results in water content measurements of biofuels. Three analytical methods based on different theories were employed to certify the water content of the reference material, including Karl Fischer coulometric titration, Karl Fischer volumetric titration and quantitative nuclear magnetic resonance. The consistency of coulometric and volumetric titration was achieved through the improvement of methods. The accuracy of the certified result was improved by the introduction of the new method of quantitative nuclear magnetic resonance. Finally, the certified value of reference material is 4.76% with an expanded uncertainty of 0.09%.

  16. Improving Reference Service: The Case for Using a Continuous Quality Improvement Method.

    ERIC Educational Resources Information Center

    Aluri, Rao

    1993-01-01

    Discusses the evaluation of library reference service; examines problems with past evaluations, including the lack of long-term planning and a systems perspective; and suggests a method for continuously monitoring and improving reference service using quality improvement tools such as checklists, cause and effect diagrams, Pareto charts, and…

  17. Validation studies of Karl Fisher reference method for moisture in cotton

    USDA-ARS?s Scientific Manuscript database

    With current international standard oven drying (SOD) techniques lacking precision and accuracy statements, a new standard reference method is needed. Volumetric Karl Fischer Titration (KFT) is a widely used measure of moisture content. The method is used in many ASTM methods, 14 NIST SRMs, and te...

  18. 7 CFR 801.7 - Reference methods and tolerances for near-infrared spectroscopy (NIRS) analyzers.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ..._of_federal_regulations/ibr_locations.html. (b) Tolerances—(1) NIRS wheat protein analyzers. The... Method 992.23. (3) NIRS corn oil, protein, and starch analyzers. The maintenance tolerances for the NIRS... methods and tolerances for near-infrared spectroscopy (NIRS) analyzers. (a) Reference methods. (1) The...

  19. 7 CFR 801.7 - Reference methods and tolerances for near-infrared spectroscopy (NIRS) analyzers.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ..._of_federal_regulations/ibr_locations.html. (b) Tolerances—(1) NIRS wheat protein analyzers. The... Method 992.23. (3) NIRS corn oil, protein, and starch analyzers. The maintenance tolerances for the NIRS... methods and tolerances for near-infrared spectroscopy (NIRS) analyzers. (a) Reference methods. (1) The...

  20. 7 CFR 801.7 - Reference methods and tolerances for near-infrared spectroscopy (NIRS) analyzers.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ..._of_federal_regulations/ibr_locations.html. (b) Tolerances—(1) NIRS wheat protein analyzers. The... Method 992.23. (3) NIRS corn oil, protein, and starch analyzers. The maintenance tolerances for the NIRS... methods and tolerances for near-infrared spectroscopy (NIRS) analyzers. (a) Reference methods. (1) The...

  1. 7 CFR 801.7 - Reference methods and tolerances for near-infrared spectroscopy (NIRS) analyzers.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ..._of_federal_regulations/ibr_locations.html. (b) Tolerances—(1) NIRS wheat protein analyzers. The... Method 992.23. (3) NIRS corn oil, protein, and starch analyzers. The maintenance tolerances for the NIRS... methods and tolerances for near-infrared spectroscopy (NIRS) analyzers. (a) Reference methods. (1) The...

  2. Methods for Scaling Icing Test Conditions

    NASA Technical Reports Server (NTRS)

    Anderson, David N.

    1995-01-01

    This report presents the results of tests at NASA Lewis to evaluate several methods to establish suitable alternative test conditions when the test facility limits the model size or operating conditions. The first method was proposed by Olsen. It can be applied when full-size models are tested and all the desired test conditions except liquid-water content can be obtained in the facility. The other two methods discussed are: a modification of the French scaling law and the AEDC scaling method. Icing tests were made with cylinders at both reference and scaled conditions representing mixed and glaze ice in the NASA Lewis Icing Research Tunnel. Reference and scale ice shapes were compared to evaluate each method. The Olsen method was tested with liquid-water content varying from 1.3 to .8 g/m(exp3). Over this range, ice shapes produced using the Olsen method were unchanged. The modified French and AEDC methods produced scaled ice shapes which approximated the reference shapes when model size was reduced to half the reference size for the glaze-ice cases tested.

  3. Elastic-wave-mode separation in TTI media with inverse-distance weighted interpolation involving position shading

    NASA Astrophysics Data System (ADS)

    Wang, Jian; Meng, Xiaohong; Zheng, Wanqiu

    2017-10-01

    The elastic-wave reverse-time migration of inhomogeneous anisotropic media is becoming the hotspot of research today. In order to ensure the accuracy of the migration, it is necessary to separate the wave mode into P-wave and S-wave before migration. For inhomogeneous media, the Kelvin-Christoffel equation can be solved in the wave-number domain by using the anisotropic parameters of the mesh nodes, and the polarization vector of the P-wave and S-wave at each node can be calculated and transformed into the space domain to obtain the quasi-differential operators. However, this method is computationally expensive, especially for the process of quasi-differential operators. In order to reduce the computational complexity, the wave-mode separation of mixed domain can be realized on the basis of a reference model in the wave-number domain. But conventional interpolation methods and reference model selection methods reduce the separation accuracy. In order to further improve the separation effect, this paper introduces an inverse-distance interpolation method involving position shading and uses the reference model selection method of random points scheme. This method adds the spatial weight coefficient K, which reflects the orientation of the reference point on the conventional IDW algorithm, and the interpolation process takes into account the combined effects of the distance and azimuth of the reference points. Numerical simulation shows that the proposed method can separate the wave mode more accurately using fewer reference models and has better practical value.

  4. The PneuCarriage Project: A Multi-Centre Comparative Study to Identify the Best Serotyping Methods for Examining Pneumococcal Carriage in Vaccine Evaluation Studies

    PubMed Central

    Satzke, Catherine; Dunne, Eileen M.; Porter, Barbara D.; Klugman, Keith P.; Mulholland, E. Kim

    2015-01-01

    Background The pneumococcus is a diverse pathogen whose primary niche is the nasopharynx. Over 90 different serotypes exist, and nasopharyngeal carriage of multiple serotypes is common. Understanding pneumococcal carriage is essential for evaluating the impact of pneumococcal vaccines. Traditional serotyping methods are cumbersome and insufficient for detecting multiple serotype carriage, and there are few data comparing the new methods that have been developed over the past decade. We established the PneuCarriage project, a large, international multi-centre study dedicated to the identification of the best pneumococcal serotyping methods for carriage studies. Methods and Findings Reference sample sets were distributed to 15 research groups for blinded testing. Twenty pneumococcal serotyping methods were used to test 81 laboratory-prepared (spiked) samples. The five top-performing methods were used to test 260 nasopharyngeal (field) samples collected from children in six high-burden countries. Sensitivity and positive predictive value (PPV) were determined for the test methods and the reference method (traditional serotyping of >100 colonies from each sample). For the alternate serotyping methods, the overall sensitivity ranged from 1% to 99% (reference method 98%), and PPV from 8% to 100% (reference method 100%), when testing the spiked samples. Fifteen methods had ≥70% sensitivity to detect the dominant (major) serotype, whilst only eight methods had ≥70% sensitivity to detect minor serotypes. For the field samples, the overall sensitivity ranged from 74.2% to 95.8% (reference method 93.8%), and PPV from 82.2% to 96.4% (reference method 99.6%). The microarray had the highest sensitivity (95.8%) and high PPV (93.7%). The major limitation of this study is that not all of the available alternative serotyping methods were included. Conclusions Most methods were able to detect the dominant serotype in a sample, but many performed poorly in detecting the minor serotype populations. Microarray with a culture amplification step was the top-performing method. Results from this comprehensive evaluation will inform future vaccine evaluation and impact studies, particularly in low-income settings, where pneumococcal disease burden remains high. PMID:26575033

  5. System and method for authentication

    DOEpatents

    Duerksen, Gary L.; Miller, Seth A.

    2015-12-29

    Described are methods and systems for determining authenticity. For example, the method may include providing an object of authentication, capturing characteristic data from the object of authentication, deriving authentication data from the characteristic data of the object of authentication, and comparing the authentication data with an electronic database comprising reference authentication data to provide an authenticity score for the object of authentication. The reference authentication data may correspond to one or more reference objects of authentication other than the object of authentication.

  6. Estimating patient-specific and anatomically correct reference model for craniomaxillofacial deformity via sparse representation

    PubMed Central

    Wang, Li; Ren, Yi; Gao, Yaozong; Tang, Zhen; Chen, Ken-Chung; Li, Jianfu; Shen, Steve G. F.; Yan, Jin; Lee, Philip K. M.; Chow, Ben; Xia, James J.; Shen, Dinggang

    2015-01-01

    Purpose: A significant number of patients suffer from craniomaxillofacial (CMF) deformity and require CMF surgery in the United States. The success of CMF surgery depends on not only the surgical techniques but also an accurate surgical planning. However, surgical planning for CMF surgery is challenging due to the absence of a patient-specific reference model. Currently, the outcome of the surgery is often subjective and highly dependent on surgeon’s experience. In this paper, the authors present an automatic method to estimate an anatomically correct reference shape of jaws for orthognathic surgery, a common type of CMF surgery. Methods: To estimate a patient-specific jaw reference model, the authors use a data-driven method based on sparse shape composition. Given a dictionary of normal subjects, the authors first use the sparse representation to represent the midface of a patient by the midfaces of the normal subjects in the dictionary. Then, the derived sparse coefficients are used to reconstruct a patient-specific reference jaw shape. Results: The authors have validated the proposed method on both synthetic and real patient data. Experimental results show that the authors’ method can effectively reconstruct the normal shape of jaw for patients. Conclusions: The authors have presented a novel method to automatically estimate a patient-specific reference model for the patient suffering from CMF deformity. PMID:26429255

  7. Analytical Bias Exceeding Desirable Quality Goal in 4 out of 5 Common Immunoassays: Results of a Native Single Serum Sample External Quality Assessment Program for Cobalamin, Folate, Ferritin, Thyroid-Stimulating Hormone, and Free T4 Analyses.

    PubMed

    Kristensen, Gunn B B; Rustad, Pål; Berg, Jens P; Aakre, Kristin M

    2016-09-01

    We undertook this study to evaluate method differences for 5 components analyzed by immunoassays, to explore whether the use of method-dependent reference intervals may compensate for method differences, and to investigate commutability of external quality assessment (EQA) materials. Twenty fresh native single serum samples, a fresh native serum pool, Nordic Federation of Clinical Chemistry Reference Serum X (serum X) (serum pool), and 2 EQA materials were sent to 38 laboratories for measurement of cobalamin, folate, ferritin, free T4, and thyroid-stimulating hormone (TSH) by 5 different measurement procedures [Roche Cobas (n = 15), Roche Modular (n = 4), Abbott Architect (n = 8), Beckman Coulter Unicel (n = 2), and Siemens ADVIA Centaur (n = 9)]. The target value for each component was calculated based on the mean of method means or measured by a reference measurement procedure (free T4). Quality specifications were based on biological variation. Local reference intervals were reported from all laboratories. Method differences that exceeded acceptable bias were found for all components except folate. Free T4 differences from the uncommonly used reference measurement procedure were large. Reference intervals differed between measurement procedures but also within 1 measurement procedure. The serum X material was commutable for all components and measurement procedures, whereas the EQA materials were noncommutable in 13 of 50 occasions (5 components, 5 methods, 2 EQA materials). The bias between the measurement procedures was unacceptably large in 4/5 tested components. Traceability to reference materials as claimed by the manufacturers did not lead to acceptable harmonization. Adjustment of reference intervals in accordance with method differences and use of commutable EQA samples are not implemented commonly. © 2016 American Association for Clinical Chemistry.

  8. External quality assurance programs as a tool for verifying standardization of measurement procedures: Pilot collaboration in Europe.

    PubMed

    Perich, C; Ricós, C; Alvarez, V; Biosca, C; Boned, B; Cava, F; Doménech, M V; Fernández-Calle, P; Fernández-Fernández, P; García-Lario, J V; Minchinela, J; Simón, M; Jansen, R

    2014-05-15

    Current external quality assurance schemes have been classified into six categories, according to their ability to verify the degree of standardization of the participating measurement procedures. SKML (Netherlands) is a Category 1 EQA scheme (commutable EQA materials with values assigned by reference methods), whereas SEQC (Spain) is a Category 5 scheme (replicate analyses of non-commutable materials with no values assigned by reference methods). The results obtained by a group of Spanish laboratories participating in a pilot study organized by SKML are examined, with the aim of pointing out the improvements over our current scheme that a Category 1 program could provide. Imprecision and bias are calculated for each analyte and laboratory, and compared with quality specifications derived from biological variation. Of the 26 analytes studied, 9 had results comparable with those from reference methods, and 10 analytes did not have comparable results. The remaining 7 analytes measured did not have available reference method values, and in these cases, comparison with the peer group showed comparable results. The reasons for disagreement in the second group can be summarized as: use of non-standard methods (IFCC without exogenous pyridoxal phosphate for AST and ALT, Jaffé kinetic at low-normal creatinine concentrations and with eGFR); non-commutability of the reference material used to assign values to the routine calibrator (calcium, magnesium and sodium); use of reference materials without established commutability instead of reference methods for AST and GGT, and lack of a systematic effort by manufacturers to harmonize results. Results obtained in this work demonstrate the important role of external quality assurance programs using commutable materials with values assigned by reference methods to correctly monitor the standardization of laboratory tests with consequent minimization of risk to patients. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Comparison of methods for the prediction of human clearance from hepatocyte intrinsic clearance for a set of reference compounds and an external evaluation set.

    PubMed

    Yamagata, Tetsuo; Zanelli, Ugo; Gallemann, Dieter; Perrin, Dominique; Dolgos, Hugues; Petersson, Carl

    2017-09-01

    1. We compared direct scaling, regression model equation and the so-called "Poulin et al." methods to scale clearance (CL) from in vitro intrinsic clearance (CL int ) measured in human hepatocytes using two sets of compounds. One reference set comprised of 20 compounds with known elimination pathways and one external evaluation set based on 17 compounds development in Merck (MS). 2. A 90% prospective confidence interval was calculated using the reference set. This interval was found relevant for the regression equation method. The three outliers identified were justified on the basis of their elimination mechanism. 3. The direct scaling method showed a systematic underestimation of clearance in both the reference and evaluation sets. The "Poulin et al." and the regression equation methods showed no obvious bias in either the reference or evaluation sets. 4. The regression model equation was slightly superior to the "Poulin et al." method in the reference set and showed a better absolute average fold error (AAFE) of value 1.3 compared to 1.6. A larger difference was observed in the evaluation set were the regression method and "Poulin et al." resulted in an AAFE of 1.7 and 2.6, respectively (removing the three compounds with known issues mentioned above). A similar pattern was observed for the correlation coefficient. Based on these data we suggest the regression equation method combined with a prospective confidence interval as the first choice for the extrapolation of human in vivo hepatic metabolic clearance from in vitro systems.

  10. Innovative application of the moisture analyzer for determination of dry mass content of processed cheese

    NASA Astrophysics Data System (ADS)

    Kowalska, Małgorzata; Janas, Sławomir; Woźniak, Magdalena

    2018-04-01

    The aim of this work was the presentation of an alternative method of determination of the total dry mass content in processed cheese. The authors claim that the presented method can be used in industry's quality control laboratories for routine testing and for quick in-process control. For the test purposes both reference method of determination of dry mass in processed cheese and moisture analyzer method were used. The tests were carried out for three different kinds of processed cheese. In accordance with the reference method, the sample was placed on a layer of silica sand and dried at the temperature of 102 °C for about 4 h. The moisture analyzer test required method validation, with regard to drying temperature range and mass of the analyzed sample. Optimum drying temperature of 110 °C was determined experimentally. For Hochland cream processed cheese sample, the total dry mass content, obtained using the reference method, was 38.92%, whereas using the moisture analyzer method, it was 38.74%. An average analysis time in case of the moisture analyzer method was 9 min. For the sample of processed cheese with tomatoes, the reference method result was 40.37%, and the alternative method result was 40.67%. For the sample of cream processed cheese with garlic the reference method gave value of 36.88%, and the alternative method, of 37.02%. An average time of those determinations was 16 min. Obtained results confirmed that use of moisture analyzer is effective. Compliant values of dry mass content were obtained for both of the used methods. According to the authors, the fact that the measurement took incomparably less time for moisture analyzer method, is a key criterion of in-process control and final quality control method selection.

  11. The PneuCarriage Project: A Multi-Centre Comparative Study to Identify the Best Serotyping Methods for Examining Pneumococcal Carriage in Vaccine Evaluation Studies.

    PubMed

    Satzke, Catherine; Dunne, Eileen M; Porter, Barbara D; Klugman, Keith P; Mulholland, E Kim

    2015-11-01

    The pneumococcus is a diverse pathogen whose primary niche is the nasopharynx. Over 90 different serotypes exist, and nasopharyngeal carriage of multiple serotypes is common. Understanding pneumococcal carriage is essential for evaluating the impact of pneumococcal vaccines. Traditional serotyping methods are cumbersome and insufficient for detecting multiple serotype carriage, and there are few data comparing the new methods that have been developed over the past decade. We established the PneuCarriage project, a large, international multi-centre study dedicated to the identification of the best pneumococcal serotyping methods for carriage studies. Reference sample sets were distributed to 15 research groups for blinded testing. Twenty pneumococcal serotyping methods were used to test 81 laboratory-prepared (spiked) samples. The five top-performing methods were used to test 260 nasopharyngeal (field) samples collected from children in six high-burden countries. Sensitivity and positive predictive value (PPV) were determined for the test methods and the reference method (traditional serotyping of >100 colonies from each sample). For the alternate serotyping methods, the overall sensitivity ranged from 1% to 99% (reference method 98%), and PPV from 8% to 100% (reference method 100%), when testing the spiked samples. Fifteen methods had ≥70% sensitivity to detect the dominant (major) serotype, whilst only eight methods had ≥70% sensitivity to detect minor serotypes. For the field samples, the overall sensitivity ranged from 74.2% to 95.8% (reference method 93.8%), and PPV from 82.2% to 96.4% (reference method 99.6%). The microarray had the highest sensitivity (95.8%) and high PPV (93.7%). The major limitation of this study is that not all of the available alternative serotyping methods were included. Most methods were able to detect the dominant serotype in a sample, but many performed poorly in detecting the minor serotype populations. Microarray with a culture amplification step was the top-performing method. Results from this comprehensive evaluation will inform future vaccine evaluation and impact studies, particularly in low-income settings, where pneumococcal disease burden remains high.

  12. An implicit adaptation algorithm for a linear model reference control system

    NASA Technical Reports Server (NTRS)

    Mabius, L.; Kaufman, H.

    1975-01-01

    This paper presents a stable implicit adaptation algorithm for model reference control. The constraints for stability are found using Lyapunov's second method and do not depend on perfect model following between the system and the reference model. Methods are proposed for satisfying these constraints without estimating the parameters on which the constraints depend.

  13. A New Dual-purpose Quality Control Dosimetry Protocol for Diagnostic Reference-level Determination in Computed Tomography.

    PubMed

    Sohrabi, Mehdi; Parsi, Masoumeh; Sina, Sedigheh

    2018-05-17

    A diagnostic reference level is an advisory dose level set by a regulatory authority in a country as an efficient criterion for protection of patients from unwanted medical exposure. In computed tomography, the direct dose measurement and data collection methods are commonly applied for determination of diagnostic reference levels. Recently, a new quality-control-based dose survey method was proposed by the authors to simplify the diagnostic reference-level determination using a retrospective quality control database usually available at a regulatory authority in a country. In line with such a development, a prospective dual-purpose quality control dosimetry protocol is proposed for determination of diagnostic reference levels in a country, which can be simply applied by quality control service providers. This new proposed method was applied to five computed tomography scanners in Shiraz, Iran, and diagnostic reference levels for head, abdomen/pelvis, sinus, chest, and lumbar spine examinations were determined. The results were compared to those obtained by the data collection and quality-control-based dose survey methods, carried out in parallel in this study, and were found to agree well within approximately 6%. This is highly acceptable for quality-control-based methods according to International Atomic Energy Agency tolerance levels (±20%).

  14. 77 FR 32632 - Ambient Air Monitoring Reference and Equivalent Methods: Designation of Three New Equivalent Methods

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-01

    ... Hydrogen Peroxide Filter Extraction'' In this method, total suspended particulate matter (TSP) is collected on glass fiber filters according to 40 CFR Appendix G to part 50, EPA Reference Method for the Determination of Lead in Suspended Particulate Matter Collected From Ambient Air. The filter samples are...

  15. Evaluation of reference crop evapotranspiration methods in arid, semi-arid and humid regions

    USDA-ARS?s Scientific Manuscript database

    It is necessary to find a simpler method in different climatic regions to calculate reference crop evapotranspiration (ETo) since the application of the FAO-56 Penman-Monteith method is often restricted due to unavailability of a full weather data set. Seven ETo methods, the de facto standard FAO-56...

  16. Serum prolactin revisited: parametric reference intervals and cross platform evaluation of polyethylene glycol precipitation-based methods for discrimination between hyperprolactinemia and macroprolactinemia.

    PubMed

    Overgaard, Martin; Pedersen, Susanne Møller

    2017-10-26

    Hyperprolactinemia diagnosis and treatment is often compromised by the presence of biologically inactive and clinically irrelevant higher-molecular-weight complexes of prolactin, macroprolactin. The objective of this study was to evaluate the performance of two macroprolactin screening regimes across commonly used automated immunoassay platforms. Parametric total and monomeric gender-specific reference intervals were determined for six immunoassay methods using female (n=96) and male sera (n=127) from healthy donors. The reference intervals were validated using 27 hyperprolactinemic and macroprolactinemic sera, whose presence of monomeric and macroforms of prolactin were determined using gel filtration chromatography (GFC). Normative data for six prolactin assays included the range of values (2.5th-97.5th percentiles). Validation sera (hyperprolactinemic and macroprolactinemic; n=27) showed higher discordant classification [mean=2.8; 95% confidence interval (CI) 1.2-4.4] for the monomer reference interval method compared to the post-polyethylene glycol (PEG) recovery cutoff method (mean=1.8; 95% CI 0.8-2.8). The two monomer/macroprolactin discrimination methods did not differ significantly (p=0.089). Among macroprolactinemic sera evaluated by both discrimination methods, the Cobas and Architect/Kryptor prolactin assays showed the lowest and the highest number of misclassifications, respectively. Current automated immunoassays for prolactin testing require macroprolactin screening methods based on PEG precipitation in order to discriminate truly from falsely elevated serum prolactin. While the recovery cutoff and monomeric reference interval macroprolactin screening methods demonstrate similar discriminative ability, the latter method also provides the clinician with an easy interpretable monomeric prolactin concentration along with a monomeric reference interval.

  17. BiliChek transcutaneous bilirubin meter overestimates serum bilirubin as measured by the Doumas reference method.

    PubMed

    Karon, Brad S; Wickremasinghe, Andrea C; Lo, Stanley F; Saenger, Amy K; Cook, Walter J

    2010-08-01

    To determine the relationship between BiliChek TcB (Respironics, Marietta GA) and Doumas reference serum or plasma total bilirubin (TSB). Pooled samples with values assigned by the Doumas reference method were used to establish the relationship between a local laboratory and reference Doumas TSB. We then established the relationship between TcB and TSB in the 3 months before and after reassignment of calibrator setpoints undertaken to match the local laboratory to Doumas reference bilirubin values. Before calibrator setpoint reassignment TSB as measured in our laboratory overestimated Doumas reference bilirubin. After calibrator adjustment laboratory TSB was within 1.7-6.8 micromol/L (0.1-0.4 mg/dL) of Doumas reference values. Mean bias between BiliChek TcB and TSB was 42.8+/-22.2 micromol/L (2.5+/-1.3mg/dL) (n=94) before and 49.6+/-22.2 micromol/L (2.9+/-1.3mg/dL) (n=115) after calibration adjustment. BiliChek TcB significantly overestimates TSB as measured by the Doumas reference method. 2010 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  18. Single-Case Designs and Qualitative Methods: Applying a Mixed Methods Research Perspective

    ERIC Educational Resources Information Center

    Hitchcock, John H.; Nastasi, Bonnie K.; Summerville, Meredith

    2010-01-01

    The purpose of this conceptual paper is to describe a design that mixes single-case (sometimes referred to as single-subject) and qualitative methods, hereafter referred to as a single-case mixed methods design (SCD-MM). Minimal attention has been given to the topic of applying qualitative methods to SCD work in the literature. These two…

  19. Gene expression studies of reference genes for quantitative real-time PCR: an overview in insects.

    PubMed

    Shakeel, Muhammad; Rodriguez, Alicia; Tahir, Urfa Bin; Jin, Fengliang

    2018-02-01

    Whenever gene expression is being examined, it is essential that a normalization process is carried out to eliminate non-biological variations. The use of reference genes, such as glyceraldehyde-3-phosphate dehydrogenase, actin, and ribosomal protein genes, is the usual method of choice for normalizing gene expression. Although reference genes are used to normalize target gene expression, a major problem is that the stability of these genes differs among tissues, developmental stages, species, and responses to abiotic factors. Therefore, the use and validation of multiple reference genes are required. This review discusses the reasons that why RT-qPCR has become the preferred method for validating results of gene expression profiles, the use of specific and non-specific dyes and the importance of use of primers and probes for qPCR as well as to discuss several statistical algorithms developed to help the validation of potential reference genes. The conflicts arising in the use of classical reference genes in gene normalization and their replacement with novel references are also discussed by citing the high stability and low stability of classical and novel reference genes under various biotic and abiotic experimental conditions by employing various methods applied for the reference genes amplification.

  20. Decentralized model reference adaptive control of large flexible structures

    NASA Technical Reports Server (NTRS)

    Lee, Fu-Ming; Fong, I-Kong; Lin, Yu-Hwan

    1988-01-01

    A decentralized model reference adaptive control (DMRAC) method is developed for large flexible structures (LFS). The development follows that of a centralized model reference adaptive control for LFS that have been shown to be feasible. The proposed method is illustrated using a simply supported beam with collocated actuators and sensors. Results show that the DMRAC can achieve either output regulation or output tracking with adequate convergence, provided the reference model inputs and their time derivatives are integrable, bounded, and approach zero as t approaches infinity.

  1. 40 CFR Table 1a to Subpart Ce of... - Emissions Limits for Small, Medium, and Large HMIWI at Designated Facilities as Defined in § 60...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) (grains per dry standard cubic foot (gr/dscf)) 115 (0.05) 69 (0.03) 34 (0.015) 3-run average (1-hour minimum sample time per run) EPA Reference Method 5 of appendix A-3 of part 60, or EPA Reference Method...-run average (1-hour minimum sample time per run) EPA Reference Method 10 or 10B of appendix A-4 of...

  2. 40 CFR Table 1a to Subpart Ce of... - Emissions Limits for Small, Medium, and Large HMIWI at Designated Facilities as Defined in § 60...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) (grains per dry standard cubic foot (gr/dscf)) 115 (0.05) 69 (0.03) 34 (0.015) 3-run average (1-hour minimum sample time per run) EPA Reference Method 5 of appendix A-3 of part 60, or EPA Reference Method...-run average (1-hour minimum sample time per run) EPA Reference Method 10 or 10B of appendix A-4 of...

  3. 40 CFR Table E-1 to Subpart E of... - Summary of Test Requirements for Reference and Class I Equivalent Methods for PM 2.5 and PM 10-2.5

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    .... accuracy 3. Filter temp. control accuracy, sampling and non-sampling 1. 2 °C2. 2 °C 3. Not more than 5 °C... Reference and Class I Equivalent Methods for PM 2.5 and PM 10-2.5 E Table E-1 to Subpart E of Part 53... MONITORING REFERENCE AND EQUIVALENT METHODS Procedures for Testing Physical (Design) and Performance...

  4. 40 CFR Table E-1 to Subpart E of... - Summary of Test Requirements for Reference and Class I Equivalent Methods for PM2.5 and PM10-2.5

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    .... accuracy 3. Filter temp. control accuracy, sampling and non-sampling 1. 2 °C2. 2 °C 3. Not more than 5 °C... Reference and Class I Equivalent Methods for PM2.5 and PM10-2.5 E Table E-1 to Subpart E of Part 53... MONITORING REFERENCE AND EQUIVALENT METHODS Procedures for Testing Physical (Design) and Performance...

  5. 40 CFR Table E-1 to Subpart E of... - Summary of Test Requirements for Reference and Class I Equivalent Methods for PM2.5 and PM10-2.5

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .... accuracy 3. Filter temp. control accuracy, sampling and non-sampling 1. 2 °C2. 2 °C 3. Not more than 5 °C... Reference and Class I Equivalent Methods for PM2.5 and PM10-2.5 E Table E-1 to Subpart E of Part 53... MONITORING REFERENCE AND EQUIVALENT METHODS Procedures for Testing Physical (Design) and Performance...

  6. 40 CFR Table E-1 to Subpart E of... - Summary of Test Requirements for Reference and Class I Equivalent Methods for PM 2.5 and PM 10-2.5

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    .... accuracy 3. Filter temp. control accuracy, sampling and non-sampling 1. 2 °C2. 2 °C 3. Not more than 5 °C... Reference and Class I Equivalent Methods for PM 2.5 and PM 10-2.5 E Table E-1 to Subpart E of Part 53... MONITORING REFERENCE AND EQUIVALENT METHODS Procedures for Testing Physical (Design) and Performance...

  7. 40 CFR 53.1 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... followed by a gravimetric mass determination, but which is not a Class I equivalent method because of... MONITORING REFERENCE AND EQUIVALENT METHODS General Provisions § 53.1 Definitions. Terms used but not defined... slope of a linear plot fitted to corresponding candidate and reference method mean measurement data...

  8. Focusing adaptive-optics for neutron spectroscopy at extreme conditions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Simeoni, G. G., E-mail: ggsimeoni@outlook.com; Physics Department E13, Technical University of Munich, D-85748 Garching; Valicu, R. G.

    2015-12-14

    Neutron Spectroscopy employing extreme-conditions sample environments is nowadays a crucial tool for the understanding of fundamental scientific questions as well as for the investigation of materials and chemical-physical properties. For all these kinds of studies, an increased neutron flux over a small sample area is needed. The prototype of a focusing neutron guide component, developed and produced completely at the neutron source FRM II in Garching (Germany), has been installed at the time-of-flight (TOF) disc-chopper neutron spectrometer TOFTOF and came into routine-operation. The design is based on the compressed Archimedes' mirror concept for finite-size divergent sources. It represents a uniquemore » device combining the supermirror technology with Adaptive Optics, suitable for broad-bandwidth thermal-cold TOF neutron spectroscopy (here optimized for 1.4–10 Å). It is able to squeeze the beam cross section down to a square centimeter, with a more than doubled signal-to-background ratio, increased efficiency at high scattering angles, and improved symmetry of the elastic resolution function. We present a comparison between the simulated and measured beam cross sections, as well as the performance of the instrument within real experiments. This work intends to show the unprecedented opportunities achievable at already existing instruments, along with useful guidelines for the design and construction of next-generation neutron spectrometers.« less

  9. Intense positron beam as a source for production of electron-positron plasma

    NASA Astrophysics Data System (ADS)

    Stoneking, M. R.; Horn-Stanja, J.; Stenson, E. V.; Pedersen, T. Sunn; Saitoh, H.; Hergenhahn, U.; Niemann, H.; Paschkowski, N.; Hugenschmidt, C.; Piochacz, C.

    2016-10-01

    We aim to produce magnetically confined, short Debye length electron-positron plasma and test predicted properties for such systems. A first challenge is obtaining large numbers of positrons; a table-top experiment (system size 5 cm) with a temperature less than 5 eV requires about 1010 positrons to have more than 10 Debye lengths in the system. The NEPOMUC facility at the FRM II research reactor in Germany is one of the world's most intense positron sources. We report on characterization (using a retarding field energy analyzer with magnetic field gradient) of the NEPOMUC beam as delivered to the open beam port at various beam energies and in both the re-moderated and primary beam configurations in order to design optimal trapping (and accumulation) schemes for production of electron-positron plasma. The intensity of the re-moderated (primary) beam is in the range 2 -3 x 107 /s (1 - 5 x 108 /s). The re-moderated beam is currently the most promising for direct injection and confinement experiments; it has a parallel energy spread of 15 - 35% and the transverse energy spread is 6 - 15% of the parallel energy. We report on the implications for injection and trapping in a dipole magnetic field as well as plans for beam development, in situ re-moderation, and accumulation. We also report results demonstrating a difference in phosphor luminescent response to low energy positrons versus electrons.

  10. X-ray Moiré deflectometry using synthetic reference images

    DOE PAGES

    Stutman, Dan; Valdivia, Maria Pia; Finkenthal, Michael

    2015-06-25

    Moiré fringe deflectometry with grating interferometers is a technique that enables refraction-based x-ray imaging using a single exposure of an object. To obtain the refraction image, the method requires a reference fringe pattern (without the object). Our study shows that, in order to avoid artifacts, the reference pattern must be exactly matched in phase with the object fringe pattern. In experiments, however, it is difficult to produce a perfectly matched reference pattern due to unavoidable interferometer drifts. We present a simple method to obtain matched reference patterns using a phase-scan procedure to generate synthetic Moiré images. As a result, themore » method will enable deflectometric diagnostics of transient phenomena such as laser-produced plasmas and could improve the sensitivity and accuracy of medical phase-contrast imaging.« less

  11. An analytic-numerical method for the construction of the reference law of operation for a class of mechanical controlled systems

    NASA Astrophysics Data System (ADS)

    Mizhidon, A. D.; Mizhidon, K. A.

    2017-04-01

    An analytic-numerical method for the construction of a reference law of operation for a class of dynamic systems describing vibrations in controlled mechanical systems is proposed. By the reference law of operation of a system, we mean a law of the system motion that satisfies all the requirements for the quality and design features of the system under permanent external disturbances. As disturbances, we consider polyharmonic functions with known amplitudes and frequencies of the harmonics but unknown initial phases. For constructing the reference law of motion, an auxiliary optimal control problem is solved in which the cost function depends on a weighting coefficient. The choice of the weighting coefficient ensures the design of the reference law. Theoretical foundations of the proposed method are given.

  12. The importance of reference materials in doping-control analysis.

    PubMed

    Mackay, Lindsey G; Kazlauskas, Rymantas

    2011-08-01

    Currently a large range of pure substance reference materials are available for calibration of doping-control methods. These materials enable traceability to the International System of Units (SI) for the results generated by World Anti-Doping Agency (WADA)-accredited laboratories. Only a small number of prohibited substances have threshold limits for which quantification is highly important. For these analytes only the highest quality reference materials that are available should be used. Many prohibited substances have no threshold limits and reference materials provide essential identity confirmation. For these reference materials the correct identity is critical and the methods used to assess identity in these cases should be critically evaluated. There is still a lack of certified matrix reference materials to support many aspects of doping analysis. However, in key areas a range of urine matrix materials have been produced for substances with threshold limits, for example 19-norandrosterone and testosterone/epitestosterone (T/E) ratio. These matrix-certified reference materials (CRMs) are an excellent independent means of checking method recovery and bias and will typically be used in method validation and then regularly as quality-control checks. They can be particularly important in the analysis of samples close to threshold limits, in which measurement accuracy becomes critical. Some reference materials for isotope ratio mass spectrometry (IRMS) analysis are available and a matrix material certified for steroid delta values is currently under production. In other new areas, for example the Athlete Biological Passport, peptide hormone testing, designer steroids, and gene doping, reference material needs still need to be thoroughly assessed and prioritised.

  13. Determination of tungsten in geochemical reference material basalt Columbia River 2 by radiochemical neutron activation analysis and inductively coupled plasma mass spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morrison, Samuel S.; Beck, Chelsie L.; Bowen, James M.

    Environmental tungsten (W) analyses are inhibited by a lack of reference materials and practical methods to remove isobaric and radiometric interferences. We present a method that evaluates the potential use of commercially available sediment, Basalt Columbia River-2 (BCR-2), as a reference material using neutron activation analysis (NAA) and mass spectrometry. Tungsten concentrations using both methods are in statistical agreement at the 95% confidence interval (92 ± 4 ng/g for NAA and 100 ±7 ng/g for mass spectrometry) with recoveries greater than 95%. These results indicate that BCR-2 may be suitable as a reference material for future studies.

  14. Estimating clinical chemistry reference values based on an existing data set of unselected animals.

    PubMed

    Dimauro, Corrado; Bonelli, Piero; Nicolussi, Paola; Rassu, Salvatore P G; Cappio-Borlino, Aldo; Pulina, Giuseppe

    2008-11-01

    In an attempt to standardise the determination of biological reference values, the International Federation of Clinical Chemistry (IFCC) has published a series of recommendations on developing reference intervals. The IFCC recommends the use of an a priori sampling of at least 120 healthy individuals. However, such a high number of samples and laboratory analysis is expensive, time-consuming and not always feasible, especially in veterinary medicine. In this paper, an alternative (a posteriori) method is described and is used to determine reference intervals for biochemical parameters of farm animals using an existing laboratory data set. The method used was based on the detection and removal of outliers to obtain a large sample of animals likely to be healthy from the existing data set. This allowed the estimation of reliable reference intervals for biochemical parameters in Sarda dairy sheep. This method may also be useful for the determination of reference intervals for different species, ages and gender.

  15. Recommendations for reference method for haemoglobinometry in human blood (ICSH standard 1986) and specifications for international haemiglobincyanide reference preparation (3rd edition). International Committee for Standardization in Haematology; Expert Panel on Haemoglobinometry.

    PubMed

    1987-01-01

    Scientific symposia on haemoglobinometry were held at the 9th Congress of the European Society of Haematology, Lisbon, 1963 (ESH 1964) and the 10th Congress of the International Society of Haematology (ISH), Stockholm, 1964 (ISH 1965). The International Committee for Standardization in Haematology (ICSH) made recommendations endorsed by the General Assembly of ICSH in Sydney on 23 August 1966 (ICSH 1967), for a reference method for haemoglobinometry and for the manufacture and distribution of an international reference preparation. Further symposia were held at the 12th Congress of the ISH, New York, 1968 (Astaldi, Sirtori & Vanzetti 1979) and at the 13th Congress of ISH, Munich, 1970 (Izak & Lewis 1972). The recommendations were reissued in 1978 (ISH 1978). On the basis of continuing experimental studies, the reference method and the specifications for the international reference preparation have been modified. The revised recommendations are described in this document.

  16. The effects of user factors and symbol referents on public symbol design using the stereotype production method.

    PubMed

    Ng, Annie W Y; Siu, Kin Wai Michael; Chan, Chetwyn C H

    2012-01-01

    This study investigated the influence of user factors and symbol referents on public symbol design among older people, using the stereotype production method for collecting user ideas during the symbol design process. Thirty-one older adults were asked to draw images based on 28 public symbol referents and to indicate their familiarity with and ease with which they visualised each referent. Differences were found between the pictorial solutions generated by males and females. However, symbol design was not influenced by participants' education level, vividness of visual imagery, object imagery preference or spatial imagery preference. Both familiar and unfamiliar referents were illustrated pictorially without much difficulty by users. The more visual the referent, the less difficulty the users had in illustrating it. The findings of this study should aid the optimisation of the stereotype production method for user-involved symbol design. Copyright © 2011 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  17. Pathology Report for Intraperitoneal Sodium Dichromate Exposure in Rats

    DTIC Science & Technology

    2015-08-12

    1 2 References 1 3 Methods 1 4 Results 2 5 Discussion...Dr. Michael Madejczyk, USARMY MEDCOM USACEHR (US)). 2 References See Appendix A for a listing of references. 3 Methods Conical tubes containing...Nonproliferative Lesions of the Rat and Mouse Hepatobiliary System Toxicol Pathol. 38(7 Suppl): 5S -81S. Toxicological Study No. S.0035303-15, December

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, Stephen F; Moore, James A

    Systems and methods are described for carrier-frequency synchronization for improved AM and TV broadcast reception. A method includes synchronizing a carrier frequency of a broadcast signal with a remote reference frequency. An apparatus includes a reference signal receiver; a phase comparator coupled to the reference signal receiver; a voltage controlled oscillator coupled to the phase comparator; and a radio frequency output coupled to the voltage controlled oscillator.

  19. The characterization and certification of a quantitative reference material for Legionella detection and quantification by qPCR.

    PubMed

    Baume, M; Garrelly, L; Facon, J P; Bouton, S; Fraisse, P O; Yardin, C; Reyrolle, M; Jarraud, S

    2013-06-01

    The characterization and certification of a Legionella DNA quantitative reference material as a primary measurement standard for Legionella qPCR. Twelve laboratories participated in a collaborative certification campaign. A candidate reference DNA material was analysed through PCR-based limiting dilution assays (LDAs). The validated data were used to statistically assign both a reference value and an associated uncertainty to the reference material. This LDA method allowed for the direct quantification of the amount of Legionella DNA per tube in genomic units (GU) and the determination of the associated uncertainties. This method could be used for the certification of all types of microbiological standards for qPCR. The use of this primary standard will improve the accuracy of Legionella qPCR measurements and the overall consistency of these measurements among different laboratories. The extensive use of this certified reference material (CRM) has been integrated in the French standard NF T90-471 (April 2010) and in the ISO Technical Specification 12 869 (Anon 2012 International Standardisation Organisation) for validating qPCR methods and ensuring the reliability of these methods. © 2013 The Society for Applied Microbiology.

  20. Comparison of two reference methods for detemining cotton fiber moisture

    USDA-ARS?s Scientific Manuscript database

    Moisture is an important quality and processing property for the cotton industry. The standard reference method for determining the moisture content in cotton fiber is the ASTM oven method (gravimetric weight loss). Several concerns have expressed on its ability to measure the actual moisture cont...

  1. 40 CFR 53.52 - Leak check test.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... MONITORING REFERENCE AND EQUIVALENT METHODS Procedures for Testing Physical (Design) and Performance Characteristics of Reference Methods and Class I and Class II Equivalent Methods for PM 2.5 or PM 10-2.5 § 53.52... to include the facility, including components, instruments, operator controls, a written procedure...

  2. Idiographic duo-trio tests using a constant-reference based on preference of each consumer: Sample presentation sequence in difference test can be customized for individual consumers to reduce error.

    PubMed

    Kim, Min-A; Sim, Hye-Min; Lee, Hye-Seong

    2016-11-01

    As reformulations and processing changes are increasingly needed in the food industry to produce healthier, more sustainable, and cost effective products while maintaining superior quality, reliable measurements of consumers' sensory perception and discrimination are becoming more critical. Consumer discrimination methods using a preferred-reference duo-trio test design have been shown to be effective in improving the discrimination performance by customizing sample presentation sequences. However, this design can add complexity to the discrimination task for some consumers, resulting in more errors in sensory discrimination. The objective of the present study was to investigate the effects of different types of test instructions using the preference-reference duo-trio test design where a paired-preference test is followed by 6 repeated preferred-reference duo-trio tests, in comparison to the analytical method using the balanced-reference duo-trio. Analyses of d' estimates (product-related measure) and probabilistic sensory discriminators in momentary numbers of subjects showing statistical significance (subject-related measure) revealed that only preferred-reference duo-trio test using affective reference-framing, either by providing no information about the reference or information on a previously preferred sample, improved the sensory discrimination more than the analytical method. No decrease in discrimination performance was observed with any type of instruction, confirming that consumers could handle the test methods. These results suggest that when repeated tests are feasible, using the affective discrimination method would be operationally more efficient as well as ecologically more reliable for measuring consumers' sensory discrimination ability. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Reference Intervals of Hematology and Clinical Chemistry Analytes for 1-Year-Old Korean Children

    PubMed Central

    Lee, Hye Ryun; Roh, Eun Youn; Chang, Ju Young

    2016-01-01

    Background Reference intervals need to be established according to age. We established reference intervals of hematology and chemistry from community-based healthy 1-yr-old children and analyzed their iron status according to the feeding methods during the first six months after birth. Methods A total of 887 children who received a medical check-up between 2010 and 2014 at Boramae Hospital (Seoul, Korea) were enrolled. A total of 534 children (247 boys and 287 girls) were enrolled as reference individuals after the exclusion of data obtained from children with suspected iron deficiency. Hematology and clinical chemistry analytes were measured, and the reference value of each analyte was estimated by using parametric (mean±2 SD) or nonparametric methods (2.5-97.5th percentile). Iron, total iron-binding capacity, and ferritin were measured, and transferrin saturation was calculated. Results As there were no differences in the mean values between boys and girls, we established the reference intervals for 1-yr-old children regardless of sex. The analysis of serum iron status according to feeding methods during the first six months revealed higher iron, ferritin, and transferrin saturation levels in children exclusively or mainly fed formula than in children exclusively or mainly fed breast milk. Conclusions We established reference intervals of hematology and clinical chemistry analytes from community-based healthy children at one year of age. These reference intervals will be useful for interpreting results of medical check-ups at one year of age. PMID:27374715

  4. Roka Listeria detection method using transcription mediated amplification to detect Listeria species in select foods and surfaces. Performance Tested Method(SM) 011201.

    PubMed

    Hua, Yang; Kaplan, Shannon; Reshatoff, Michael; Hu, Ernie; Zukowski, Alexis; Schweis, Franz; Gin, Cristal; Maroni, Brett; Becker, Michael; Wisniewski, Michele

    2012-01-01

    The Roka Listeria Detection Assay was compared to the reference culture methods for nine select foods and three select surfaces. The Roka method used Half-Fraser Broth for enrichment at 35 +/- 2 degrees C for 24-28 h. Comparison of Roka's method to reference methods requires an unpaired approach. Each method had a total of 545 samples inoculated with a Listeria strain. Each food and surface was inoculated with a different strain of Listeria at two different levels per method. For the dairy products (Brie cheese, whole milk, and ice cream), our method was compared to AOAC Official Method(SM) 993.12. For the ready-to-eat meats (deli chicken, cured ham, chicken salad, and hot dogs) and environmental surfaces (sealed concrete, stainless steel, and plastic), these samples were compared to the U.S. Department of Agriculture/Food Safety and Inspection Service-Microbiology Laboratory Guidebook (USDA/FSIS-MLG) method MLG 8.07. Cold-smoked salmon and romaine lettuce were compared to the U.S. Food and Drug Administration/Bacteriological Analytical Manual, Chapter 10 (FDA/BAM) method. Roka's method had 358 positives out of 545 total inoculated samples compared to 332 positive for the reference methods. Overall the probability of detection analysis of the results showed better or equivalent performance compared to the reference methods.

  5. What is the best reference RNA? And other questions regarding the design and analysis of two-color microarray experiments.

    PubMed

    Kerr, Kathleen F; Serikawa, Kyle A; Wei, Caimiao; Peters, Mette A; Bumgarner, Roger E

    2007-01-01

    The reference design is a practical and popular choice for microarray studies using two-color platforms. In the reference design, the reference RNA uses half of all array resources, leading investigators to ask: What is the best reference RNA? We propose a novel method for evaluating reference RNAs and present the results of an experiment that was specially designed to evaluate three common choices of reference RNA. We found no compelling evidence in favor of any particular reference. In particular, a commercial reference showed no advantage in our data. Our experimental design also enabled a new way to test the effectiveness of pre-processing methods for two-color arrays. Our results favor using intensity normalization and foregoing background subtraction. Finally, we evaluate the sensitivity and specificity of data quality filters, and we propose a new filter that can be applied to any experimental design and does not rely on replicate hybridizations.

  6. Tags, wireless communication systems, tag communication methods, and wireless communications methods

    DOEpatents

    Scott,; Jeff W. , Pratt; Richard, M [Richland, WA

    2006-09-12

    Tags, wireless communication systems, tag communication methods, and wireless communications methods are described. In one aspect, a tag includes a plurality of antennas configured to receive a plurality of first wireless communication signals comprising data from a reader, a plurality of rectifying circuits coupled with. respective individual ones of the antennas and configured to provide rectified signals corresponding to the first wireless communication signals, wherein the rectified signals are combined to produce a composite signal, an adaptive reference circuit configured to vary a reference signal responsive to the composite signal, a comparator coupled with the adaptive reference circuit and the rectifying circuits and configured to compare the composite signal with respect to the reference signal and to output the data responsive to the comparison, and processing circuitry configured to receive the data from the comparator and to process the data.

  7. A numerical fragment basis approach to SCF calculations.

    NASA Astrophysics Data System (ADS)

    Hinde, Robert J.

    1997-11-01

    The counterpoise method is often used to correct for basis set superposition error in calculations of the electronic structure of bimolecular systems. One drawback of this approach is the need to specify a ``reference state'' for the system; for reactive systems, the choice of an unambiguous reference state may be difficult. An example is the reaction F^- + HCl arrow HF + Cl^-. Two obvious reference states for this reaction are F^- + HCl and HF + Cl^-; however, different counterpoise-corrected interaction energies are obtained using these two reference states. We outline a method for performing SCF calculations which employs numerical basis functions; this method attempts to eliminate basis set superposition errors in an a priori fashion. We test the proposed method on two one-dimensional, three-center systems and discuss the possibility of extending our approach to include electron correlation effects.

  8. A Flexible and Accurate Genotype Imputation Method for the Next Generation of Genome-Wide Association Studies

    PubMed Central

    Howie, Bryan N.; Donnelly, Peter; Marchini, Jonathan

    2009-01-01

    Genotype imputation methods are now being widely used in the analysis of genome-wide association studies. Most imputation analyses to date have used the HapMap as a reference dataset, but new reference panels (such as controls genotyped on multiple SNP chips and densely typed samples from the 1,000 Genomes Project) will soon allow a broader range of SNPs to be imputed with higher accuracy, thereby increasing power. We describe a genotype imputation method (IMPUTE version 2) that is designed to address the challenges presented by these new datasets. The main innovation of our approach is a flexible modelling framework that increases accuracy and combines information across multiple reference panels while remaining computationally feasible. We find that IMPUTE v2 attains higher accuracy than other methods when the HapMap provides the sole reference panel, but that the size of the panel constrains the improvements that can be made. We also find that imputation accuracy can be greatly enhanced by expanding the reference panel to contain thousands of chromosomes and that IMPUTE v2 outperforms other methods in this setting at both rare and common SNPs, with overall error rates that are 15%–20% lower than those of the closest competing method. One particularly challenging aspect of next-generation association studies is to integrate information across multiple reference panels genotyped on different sets of SNPs; we show that our approach to this problem has practical advantages over other suggested solutions. PMID:19543373

  9. Quality evaluation of no-reference MR images using multidirectional filters and image statistics.

    PubMed

    Jang, Jinseong; Bang, Kihun; Jang, Hanbyol; Hwang, Dosik

    2018-09-01

    This study aimed to develop a fully automatic, no-reference image-quality assessment (IQA) method for MR images. New quality-aware features were obtained by applying multidirectional filters to MR images and examining the feature statistics. A histogram of these features was then fitted to a generalized Gaussian distribution function for which the shape parameters yielded different values depending on the type of distortion in the MR image. Standard feature statistics were established through a training process based on high-quality MR images without distortion. Subsequently, the feature statistics of a test MR image were calculated and compared with the standards. The quality score was calculated as the difference between the shape parameters of the test image and the undistorted standard images. The proposed IQA method showed a >0.99 correlation with the conventional full-reference assessment methods; accordingly, this proposed method yielded the best performance among no-reference IQA methods for images containing six types of synthetic, MR-specific distortions. In addition, for authentically distorted images, the proposed method yielded the highest correlation with subjective assessments by human observers, thus demonstrating its superior performance over other no-reference IQAs. Our proposed IQA was designed to consider MR-specific features and outperformed other no-reference IQAs designed mainly for photographic images. Magn Reson Med 80:914-924, 2018. © 2018 International Society for Magnetic Resonance in Medicine. © 2018 International Society for Magnetic Resonance in Medicine.

  10. Metabarcoding of marine nematodes – evaluation of reference datasets used in tree-based taxonomy assignment approach

    PubMed Central

    2016-01-01

    Abstract Background Metabarcoding is becoming a common tool used to assess and compare diversity of organisms in environmental samples. Identification of OTUs is one of the critical steps in the process and several taxonomy assignment methods were proposed to accomplish this task. This publication evaluates the quality of reference datasets, alongside with several alignment and phylogeny inference methods used in one of the taxonomy assignment methods, called tree-based approach. This approach assigns anonymous OTUs to taxonomic categories based on relative placements of OTUs and reference sequences on the cladogram and support that these placements receive. New information In tree-based taxonomy assignment approach, reliable identification of anonymous OTUs is based on their placement in monophyletic and highly supported clades together with identified reference taxa. Therefore, it requires high quality reference dataset to be used. Resolution of phylogenetic trees is strongly affected by the presence of erroneous sequences as well as alignment and phylogeny inference methods used in the process. Two preparation steps are essential for the successful application of tree-based taxonomy assignment approach. Curated collections of genetic information do include erroneous sequences. These sequences have detrimental effect on the resolution of cladograms used in tree-based approach. They must be identified and excluded from the reference dataset beforehand. Various combinations of multiple sequence alignment and phylogeny inference methods provide cladograms with different topology and bootstrap support. These combinations of methods need to be tested in order to determine the one that gives highest resolution for the particular reference dataset. Completing the above mentioned preparation steps is expected to decrease the number of unassigned OTUs and thus improve the results of the tree-based taxonomy assignment approach. PMID:27932919

  11. The impact of change in albumin assay on reference intervals, prevalence of 'hypoalbuminaemia' and albumin prescriptions.

    PubMed

    Coley-Grant, Deon; Herbert, Mike; Cornes, Michael P; Barlow, Ian M; Ford, Clare; Gama, Rousseau

    2016-01-01

    We studied the impact on reference intervals, classification of patients with hypoalbuminaemia and albumin infusion prescriptions on changing from a bromocresol green (BCG) to a bromocresol purple (BCP) serum albumin assay. Passing-Bablok regression analysis and Bland-Altman plot were used to compare Abbott BCP and Roche BCG methods. Linear regression analysis was used to compare in-house and an external laboratory Abbott BCP serum albumin results. Reference intervals for Abbott BCP serum albumin were derived in two different laboratories using pathology data from adult patients in primary care. Prescriptions for 20% albumin infusions were compared one year before and one year after changing the albumin method. Abbott BCP assay had a negative bias of approximately 6 g/L compared with Roche BCG method.There was good agreement (y = 1.04 x - 1.03; R(2 )= 0.9933) between in-house and external laboratory Abbott BCP results. Reference intervals for the serum albumin Abbott BCP assay were 31-45 g/L, different to those recommended by Pathology Harmony and the manufacturers (35-50 g/L). Following the change in method there was a large increase in the number of patients classified as hypoalbuminaemic using Pathology Harmony references intervals (32%) but not when retrospectively compared to locally derived reference intervals (16%) compared with the previous year (12%). The method change was associated with a 44.6% increase in albumin prescriptions. This equated to an annual increase in expenditure of £35,234. We suggest that serum albumin reference intervals be method specific to prevent misclassification of albumin status in patients. Change in albumin methodology may have significant impact on hospital resources. © The Author(s) 2015.

  12. Metabarcoding of marine nematodes - evaluation of reference datasets used in tree-based taxonomy assignment approach.

    PubMed

    Holovachov, Oleksandr

    2016-01-01

    Metabarcoding is becoming a common tool used to assess and compare diversity of organisms in environmental samples. Identification of OTUs is one of the critical steps in the process and several taxonomy assignment methods were proposed to accomplish this task. This publication evaluates the quality of reference datasets, alongside with several alignment and phylogeny inference methods used in one of the taxonomy assignment methods, called tree-based approach. This approach assigns anonymous OTUs to taxonomic categories based on relative placements of OTUs and reference sequences on the cladogram and support that these placements receive. In tree-based taxonomy assignment approach, reliable identification of anonymous OTUs is based on their placement in monophyletic and highly supported clades together with identified reference taxa. Therefore, it requires high quality reference dataset to be used. Resolution of phylogenetic trees is strongly affected by the presence of erroneous sequences as well as alignment and phylogeny inference methods used in the process. Two preparation steps are essential for the successful application of tree-based taxonomy assignment approach. Curated collections of genetic information do include erroneous sequences. These sequences have detrimental effect on the resolution of cladograms used in tree-based approach. They must be identified and excluded from the reference dataset beforehand.Various combinations of multiple sequence alignment and phylogeny inference methods provide cladograms with different topology and bootstrap support. These combinations of methods need to be tested in order to determine the one that gives highest resolution for the particular reference dataset.Completing the above mentioned preparation steps is expected to decrease the number of unassigned OTUs and thus improve the results of the tree-based taxonomy assignment approach.

  13. Validating fatty acid intake as estimated by an FFQ: how does the 24 h recall perform as reference method compared with the duplicate portion?

    PubMed

    Trijsburg, Laura; de Vries, Jeanne Hm; Hollman, Peter Ch; Hulshof, Paul Jm; van 't Veer, Pieter; Boshuizen, Hendriek C; Geelen, Anouk

    2018-05-08

    To compare the performance of the commonly used 24 h recall (24hR) with the more distinct duplicate portion (DP) as reference method for validation of fatty acid intake estimated with an FFQ. Intakes of SFA, MUFA, n-3 fatty acids and linoleic acid (LA) were estimated by chemical analysis of two DP and by on average five 24hR and two FFQ. Plasma n-3 fatty acids and LA were used to objectively compare ranking of individuals based on DP and 24hR. Multivariate measurement error models were used to estimate validity coefficients and attenuation factors for the FFQ with the DP and 24hR as reference methods. Wageningen, the Netherlands. Ninety-two men and 106 women (aged 20-70 years). Validity coefficients for the fatty acid estimates by the FFQ tended to be lower when using the DP as reference method compared with the 24hR. Attenuation factors for the FFQ tended to be slightly higher based on the DP than those based on the 24hR as reference method. Furthermore, when using plasma fatty acids as reference, the DP showed comparable to slightly better ranking of participants according to their intake of n-3 fatty acids (0·33) and n-3:LA (0·34) than the 24hR (0·22 and 0·24, respectively). The 24hR gives only slightly different results compared with the distinctive but less feasible DP, therefore use of the 24hR seems appropriate as the reference method for FFQ validation of fatty acid intake.

  14. 76 FR 19769 - Agency Information Collection Activities; Proposed Collection; Comment Request; Application for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-08

    ... Activities; Proposed Collection; Comment Request; Application for Reference and Equivalent Method... ID No. EPA-HQ- ORD-2005-0530, by one of the following methods: http://www.regulations.gov : Follow... instruments, or any other applicant for a reference or an equivalent method determination. Title: Application...

  15. The Myth of "Scientific Method" in Contemporary Educational Research

    ERIC Educational Resources Information Center

    Rowbottom, Darrell Patrick; Aiston, Sarah Jane

    2006-01-01

    Whether educational research should employ the "scientific method" has been a recurring issue in its history. Hence, textbooks on research methods continue to perpetuate the idea that research students ought to choose between competing camps: "positivist" or "interpretivist". In reference to one of the most widely referred to educational research…

  16. A NEW APPROACH FOR CULTURING LEMNA MINOR (DUCKWEED) AND STANDARDIZED METHOD FOR USING ATRAZINE AS A REFERENCE TOXICANT

    EPA Science Inventory

    Lemna minor (Duckweed) is commonly used in aquatic toxicity investigations. Methods for culturing and testing with reference toxicants, such as atrazine, are somewhat variable among researchers. Our goal was to develop standardized methods of culturing and testing for use with L....

  17. 40 CFR 53.52 - Leak check test.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... MONITORING REFERENCE AND EQUIVALENT METHODS Procedures for Testing Physical (Design) and Performance Characteristics of Reference Methods and Class I and Class II Equivalent Methods for PM2.5 or PM10â2.5 § 53.52... to include the facility, including components, instruments, operator controls, a written procedure...

  18. 40 CFR 53.52 - Leak check test.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... MONITORING REFERENCE AND EQUIVALENT METHODS Procedures for Testing Physical (Design) and Performance Characteristics of Reference Methods and Class I and Class II Equivalent Methods for PM2.5 or PM10â2.5 § 53.52... to include the facility, including components, instruments, operator controls, a written procedure...

  19. 40 CFR 53.52 - Leak check test.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... MONITORING REFERENCE AND EQUIVALENT METHODS Procedures for Testing Physical (Design) and Performance Characteristics of Reference Methods and Class I and Class II Equivalent Methods for PM2.5 or PM10â2.5 § 53.52... to include the facility, including components, instruments, operator controls, a written procedure...

  20. Correlative multiple porosimetries for reservoir sandstones with adoption of a new reference-sample-guided computed-tomographic method.

    PubMed

    Jin, Jae Hwa; Kim, Junho; Lee, Jeong-Yil; Oh, Young Min

    2016-07-22

    One of the main interests in petroleum geology and reservoir engineering is to quantify the porosity of reservoir beds as accurately as possible. A variety of direct measurements, including methods of mercury intrusion, helium injection and petrographic image analysis, have been developed; however, their application frequently yields equivocal results because these methods are different in theoretical bases, means of measurement, and causes of measurement errors. Here, we present a set of porosities measured in Berea Sandstone samples by the multiple methods, in particular with adoption of a new method using computed tomography and reference samples. The multiple porosimetric data show a marked correlativeness among different methods, suggesting that these methods are compatible with each other. The new method of reference-sample-guided computed tomography is more effective than the previous methods when the accompanied merits such as experimental conveniences are taken into account.

  1. Correlative multiple porosimetries for reservoir sandstones with adoption of a new reference-sample-guided computed-tomographic method

    PubMed Central

    Jin, Jae Hwa; Kim, Junho; Lee, Jeong-Yil; Oh, Young Min

    2016-01-01

    One of the main interests in petroleum geology and reservoir engineering is to quantify the porosity of reservoir beds as accurately as possible. A variety of direct measurements, including methods of mercury intrusion, helium injection and petrographic image analysis, have been developed; however, their application frequently yields equivocal results because these methods are different in theoretical bases, means of measurement, and causes of measurement errors. Here, we present a set of porosities measured in Berea Sandstone samples by the multiple methods, in particular with adoption of a new method using computed tomography and reference samples. The multiple porosimetric data show a marked correlativeness among different methods, suggesting that these methods are compatible with each other. The new method of reference-sample-guided computed tomography is more effective than the previous methods when the accompanied merits such as experimental conveniences are taken into account. PMID:27445105

  2. Performance of three reflectance calibration methods for airborne hyperspectral spectrometer data.

    PubMed

    Miura, Tomoaki; Huete, Alfredo R

    2009-01-01

    In this study, the performances and accuracies of three methods for converting airborne hyperspectral spectrometer data to reflectance factors were characterized and compared. The "reflectance mode (RM)" method, which calibrates a spectrometer against a white reference panel prior to mounting on an aircraft, resulted in spectral reflectance retrievals that were biased and distorted. The magnitudes of these bias errors and distortions varied significantly, depending on time of day and length of the flight campaign. The "linear-interpolation (LI)" method, which converts airborne spectrometer data by taking a ratio of linearly-interpolated reference values from the preflight and post-flight reference panel readings, resulted in precise, but inaccurate reflectance retrievals. These reflectance spectra were not distorted, but were subject to bias errors of varying magnitudes dependent on the flight duration length. The "continuous panel (CP)" method uses a multi-band radiometer to obtain continuous measurements over a reference panel throughout the flight campaign, in order to adjust the magnitudes of the linear-interpolated reference values from the preflight and post-flight reference panel readings. Airborne hyperspectral reflectance retrievals obtained using this method were found to be the most accurate and reliable reflectance calibration method. The performances of the CP method in retrieving accurate reflectance factors were consistent throughout time of day and for various flight durations. Based on the dataset analyzed in this study, the uncertainty of the CP method has been estimated to be 0.0025 ± 0.0005 reflectance units for the wavelength regions not affected by atmospheric absorptions. The RM method can produce reasonable results only for a very short-term flight (e.g., < 15 minutes) conducted around a local solar noon. The flight duration should be kept shorter than 30 minutes for the LI method to produce results with reasonable accuracies. An important advantage of the CP method is that the method can be used for long-duration flight campaigns (e.g., 1-2 hours). Although this study focused on reflectance calibration of airborne spectrometer data, the methods evaluated in this study and the results obtained are directly applicable to ground spectrometer measurements.

  3. Establishment of the Ph. Eur. erythropoietin chemical reference substance batch 1.

    PubMed

    Burns, C; Bristow, A F; Buchheit, K H; Daas, A; Wierer, M; Costanzo, A

    2015-01-01

    The Erythropoietin (EPO) European Pharmacopoeia (Ph. Eur.) Biological Reference Preparation (BRP) batch 3 was calibrated in 2006 by in vivo bioassay and was used as a reference preparation for these assays as well as for the physicochemical methods in the Ph. Eur. monograph Erythropoietin concentrated solution (1316). In order to avoid the frequent replacement of this standard and thus reduce the use of animals, a new EPO Chemical Reference Substance (CRS) was established to be used solely for the physicochemical methods. Here we report the outcome of a collaborative study aimed at demonstrating the suitability of the candidate CRS (cCRS) as a reference for the physicochemical methods in the Ph. Eur. monograph. Results from the study demonstrated that for the physicochemical methods currently required in the monograph (capillary zone electrophoresis (CZE), polyacrylamide gel electrophoresis (PAGE)/immunoblotting and peptide mapping), the cCRS is essentially identical to the existing BRP. However, data also indicated that, for the physicochemical methods under consideration for inclusion in a revised monograph (test for oxidised forms and glycan mapping), the suitability of the cCRS as a reference needs to be confirmed with additional work. Further to completion of the study, the Ph. Eur. Commission adopted the cCRS as "Erythropoietin for physicochemical tests CRS batch 1" to be used for CZE, PAGE/immunoblotting and peptide mapping.

  4. Empirical Bayes approach to the estimation of "unsafety": the multivariate regression method.

    PubMed

    Hauer, E

    1992-10-01

    There are two kinds of clues to the unsafety of an entity: its traits (such as traffic, geometry, age, or gender) and its historical accident record. The Empirical Bayes approach to unsafety estimation makes use of both kinds of clues. It requires information about the mean and the variance of the unsafety in a "reference population" of similar entities. The method now in use for this purpose suffers from several shortcomings. First, a very large reference population is required. Second, the choice of reference population is to some extent arbitrary. Third, entities in the reference population usually cannot match the traits of the entity the unsafety of which is estimated. To alleviate these shortcomings the multivariate regression method for estimating the mean and variance of unsafety in reference populations is offered. Its logical foundations are described and its soundness is demonstrated. The use of the multivariate method makes the Empirical Bayes approach to unsafety estimation applicable to a wider range of circumstances and yields better estimates of unsafety. The application of the method to the tasks of identifying deviant entities and of estimating the effect of interventions on unsafety are discussed and illustrated by numerical examples.

  5. Decoupling feedforward and feedback structures in hybrid active noise control systems for uncorrelated narrowband disturbances

    NASA Astrophysics Data System (ADS)

    Wu, Lifu; Qiu, Xiaojun; Burnett, Ian S.; Guo, Yecai

    2015-08-01

    Hybrid feedforward and feedback structures are useful for active noise control (ANC) applications where the noise can only be partially obtained with reference sensors. The traditional method uses the secondary signals of both the feedforward and feedback structures to synthesize a reference signal for the feedback structure in the hybrid structure. However, this approach introduces coupling between the feedforward and feedback structures and parameter changes in one structure affect the other during adaptation such that the feedforward and feedback structures must be optimized simultaneously in practical ANC system design. Two methods are investigated in this paper to remove such coupling effects. One is a simplified method, which uses the error signal directly as the reference signal in the feedback structure, and the second method generates the reference signal for the feedback structure by using only the secondary signal from the feedback structure and utilizes the generated reference signal as the error signal of the feedforward structure. Because the two decoupling methods can optimize the feedforward and feedback structures separately, they provide more flexibility in the design and optimization of the adaptive filters in practical ANC applications.

  6. Solving multi-objective optimization problems in conservation with the reference point method

    PubMed Central

    Dujardin, Yann; Chadès, Iadine

    2018-01-01

    Managing the biodiversity extinction crisis requires wise decision-making processes able to account for the limited resources available. In most decision problems in conservation biology, several conflicting objectives have to be taken into account. Most methods used in conservation either provide suboptimal solutions or use strong assumptions about the decision-maker’s preferences. Our paper reviews some of the existing approaches to solve multi-objective decision problems and presents new multi-objective linear programming formulations of two multi-objective optimization problems in conservation, allowing the use of a reference point approach. Reference point approaches solve multi-objective optimization problems by interactively representing the preferences of the decision-maker with a point in the criteria (objectives) space, called the reference point. We modelled and solved the following two problems in conservation: a dynamic multi-species management problem under uncertainty and a spatial allocation resource management problem. Results show that the reference point method outperforms classic methods while illustrating the use of an interactive methodology for solving combinatorial problems with multiple objectives. The method is general and can be adapted to a wide range of ecological combinatorial problems. PMID:29293650

  7. A method of camera calibration in the measurement process with reference mark for approaching observation space target

    NASA Astrophysics Data System (ADS)

    Zhang, Hua; Zeng, Luan

    2017-11-01

    Binocular stereoscopic vision can be used for space-based space targets near observation. In order to solve the problem that the traditional binocular vision system cannot work normally after interference, an online calibration method of binocular stereo measuring camera with self-reference is proposed. The method uses an auxiliary optical imaging device to insert the image of the standard reference object into the edge of the main optical path and image with the target on the same focal plane, which is equivalent to a standard reference in the binocular imaging optical system; When the position of the system and the imaging device parameters are disturbed, the image of the standard reference will change accordingly in the imaging plane, and the position of the standard reference object does not change. The camera's external parameters can be re-calibrated by the visual relationship of the standard reference object. The experimental results show that the maximum mean square error of the same object can be reduced from the original 72.88mm to 1.65mm when the right camera is deflected by 0.4 degrees and the left camera is high and low with 0.2° rotation. This method can realize the online calibration of binocular stereoscopic vision measurement system, which can effectively improve the anti - jamming ability of the system.

  8. An automated and objective method for age partitioning of reference intervals based on continuous centile curves.

    PubMed

    Yang, Qian; Lew, Hwee Yeong; Peh, Raymond Hock Huat; Metz, Michael Patrick; Loh, Tze Ping

    2016-10-01

    Reference intervals are the most commonly used decision support tool when interpreting quantitative laboratory results. They may require partitioning to better describe subpopulations that display significantly different reference values. Partitioning by age is particularly important for the paediatric population since there are marked physiological changes associated with growth and maturation. However, most partitioning methods are either technically complex or require prior knowledge of the underlying physiology/biological variation of the population. There is growing interest in the use of continuous centile curves, which provides seamless laboratory reference values as a child grows, as an alternative to rigidly described fixed reference intervals. However, the mathematical functions that describe these curves can be complex and may not be easily implemented in laboratory information systems. Hence, the use of fixed reference intervals is expected to continue for a foreseeable time. We developed a method that objectively proposes optimised age partitions and reference intervals for quantitative laboratory data (http://research.sph.nus.edu.sg/pp/ppResult.aspx), based on the sum of gradient that best describes the underlying distribution of the continuous centile curves. It is hoped that this method may improve the selection of age intervals for partitioning, which is receiving increasing attention in paediatric laboratory medicine. Copyright © 2016 Royal College of Pathologists of Australasia. Published by Elsevier B.V. All rights reserved.

  9. A Unified Approach to Genotype Imputation and Haplotype-Phase Inference for Large Data Sets of Trios and Unrelated Individuals

    PubMed Central

    Browning, Brian L.; Browning, Sharon R.

    2009-01-01

    We present methods for imputing data for ungenotyped markers and for inferring haplotype phase in large data sets of unrelated individuals and parent-offspring trios. Our methods make use of known haplotype phase when it is available, and our methods are computationally efficient so that the full information in large reference panels with thousands of individuals is utilized. We demonstrate that substantial gains in imputation accuracy accrue with increasingly large reference panel sizes, particularly when imputing low-frequency variants, and that unphased reference panels can provide highly accurate genotype imputation. We place our methodology in a unified framework that enables the simultaneous use of unphased and phased data from trios and unrelated individuals in a single analysis. For unrelated individuals, our imputation methods produce well-calibrated posterior genotype probabilities and highly accurate allele-frequency estimates. For trios, our haplotype-inference method is four orders of magnitude faster than the gold-standard PHASE program and has excellent accuracy. Our methods enable genotype imputation to be performed with unphased trio or unrelated reference panels, thus accounting for haplotype-phase uncertainty in the reference panel. We present a useful measure of imputation accuracy, allelic R2, and show that this measure can be estimated accurately from posterior genotype probabilities. Our methods are implemented in version 3.0 of the BEAGLE software package. PMID:19200528

  10. 40 CFR 90.7 - Reference materials.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS General § 90.7 Reference materials... Fuels by the Research Method Appendix A to subpart D, Table 3. ASTM D2700-92: Standard Test Method for...

  11. 40 CFR 90.7 - Reference materials.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS General § 90.7 Reference materials... Fuels by the Research Method Appendix A to subpart D, Table 3. ASTM D2700-92: Standard Test Method for...

  12. 40 CFR 90.7 - Reference materials.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS General § 90.7 Reference materials... Fuels by the Research Method Appendix A to subpart D, Table 3. ASTM D2700-92: Standard Test Method for...

  13. Validation of miRNA genes suitable as reference genes in qPCR analyses of miRNA gene expression in Atlantic salmon (Salmo salar).

    PubMed

    Johansen, Ilona; Andreassen, Rune

    2014-12-23

    MicroRNAs (miRNAs) are an abundant class of endogenous small RNA molecules that downregulate gene expression at the post-transcriptional level. They play important roles by regulating genes that control multiple biological processes, and recent years there has been an increased interest in studying miRNA genes and miRNA gene expression. The most common method applied to study gene expression of single genes is quantitative PCR (qPCR). However, before expression of mature miRNAs can be studied robust qPCR methods (miRNA-qPCR) must be developed. This includes identification and validation of suitable reference genes. We are particularly interested in Atlantic salmon (Salmo salar). This is an economically important aquaculture species, but no reference genes dedicated for use in miRNA-qPCR methods has been validated for this species. Our aim was, therefore, to identify suitable reference genes for miRNA-qPCR methods in Salmo salar. We used a systematic approach where we utilized similar studies in other species, some biological criteria, results from deep sequencing of small RNAs and, finally, experimental validation of candidate reference genes by qPCR to identify the most suitable reference genes. Ssa-miR-25-3p was identified as most suitable single reference gene. The best combinations of two reference genes were ssa-miR-25-3p and ssa-miR-455-5p. These two genes were constitutively and stably expressed across many different tissues. Furthermore, infectious salmon anaemia did not seem to affect their expression levels. These genes were amplified with high specificity, good efficiency and the qPCR assays showed a good linearity when applying a simple cybergreen miRNA-PCR method using miRNA gene specific forward primers. We have identified suitable reference genes for miRNA-qPCR in Atlantic salmon. These results will greatly facilitate further studies on miRNA genes in this species. The reference genes identified are conserved genes that are identical in their mature sequence in many aquaculture species. Therefore, they may also be suitable as reference genes in other teleosts. Finally, the systematic approach used in our study successfully identified suitable reference genes, suggesting that this may be a useful strategy to apply in similar validation studies in other aquaculture species.

  14. Enhancing the Equating of Item Difficulty Metrics: Estimation of Reference Distribution. Research Report. ETS RR-14-07

    ERIC Educational Resources Information Center

    Ali, Usama S.; Walker, Michael E.

    2014-01-01

    Two methods are currently in use at Educational Testing Service (ETS) for equating observed item difficulty statistics. The first method involves the linear equating of item statistics in an observed sample to reference statistics on the same items. The second method, or the item response curve (IRC) method, involves the summation of conditional…

  15. Evaluation of reference evapotranspiration methods in arid, semiarid, and humid regions

    Treesearch

    Fei Gao; Gary Feng; Ying Ouyang; Huixiao Wang; Daniel Fisher; Ardeshir Adeli; Johnie Jenkins

    2017-01-01

    It is often necessary to find a simpler method in different climatic regions to calculate reference crop evapotranspiration (ETo) since the application of the FAO-56 Penman-Monteith method is often restricted due to the unavailability of a comprehensive weather dataset. Seven ETo methods, namely the standard FAO-56 Penman-Monteith, the FAO-24 Radiation, FAO-24 Blaney...

  16. Reference interval computation: which method (not) to choose?

    PubMed

    Pavlov, Igor Y; Wilson, Andrew R; Delgado, Julio C

    2012-07-11

    When different methods are applied to reference interval (RI) calculation the results can sometimes be substantially different, especially for small reference groups. If there are no reliable RI data available, there is no way to confirm which method generates results closest to the true RI. We randomly drawn samples obtained from a public database for 33 markers. For each sample, RIs were calculated by bootstrapping, parametric, and Box-Cox transformed parametric methods. Results were compared to the values of the population RI. For approximately half of the 33 markers, results of all 3 methods were within 3% of the true reference value. For other markers, parametric results were either unavailable or deviated considerably from the true values. The transformed parametric method was more accurate than bootstrapping for sample size of 60, very close to bootstrapping for sample size 120, but in some cases unavailable. We recommend against using parametric calculations to determine RIs. The transformed parametric method utilizing Box-Cox transformation would be preferable way of RI calculation, if it satisfies normality test. If not, the bootstrapping is always available, and is almost as accurate and precise as the transformed parametric method. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. Evaluation of home allergen sampling devices.

    PubMed

    Sercombe, J K; Liu-Brennan, D; Garcia, M L; Tovey, E R

    2005-04-01

    Simple, inexpensive methods of sampling from allergen reservoirs are necessary for large-scale studies or low-cost householder-operated allergen measurement. We tested two commercial devices: the Indoor Biotechnologies Mitest Dust Collector and the Drager Bio-Check Allergen Control; two devices of our own design: the Electrostatic Cloth Sampler (ECS) and the Press Tape Sampler (PTS); and a Vacuum Sampler as used in many allergen studies (our Reference Method). Devices were used to collect dust mite allergen samples from 16 domestic carpets. Results were examined for correlations between the sampling methods. With mite allergen concentration expressed as microg/g, the Mitest, the ECS and the PTS correlated with the Reference Method but not with each other. When mite allergen concentration was expressed as microg/m2 the Mitest and the ECS correlated with the Reference Method but the PTS did not. In the high allergen conditions of this study, the Drager Bio-Check did not relate to any methods. The Mitest Dust Collector, the ECS and the PTS show performance consistent with the Reference Method. Many techniques can be used to collect dust mite allergen samples. More investigation is needed to prove any method as superior for estimating allergen exposure.

  18. Electrophysiological Responses to Expectancy Violations in Semantic and Gambling Tasks: A Comparison of Different EEG Reference Approaches

    PubMed Central

    Li, Ya; Wang, Yongchun; Zhang, Baoqiang; Wang, Yonghui; Zhou, Xiaolin

    2018-01-01

    Dynamically evaluating the outcomes of our actions and thoughts is a fundamental cognitive ability. Given its excellent temporal resolution, the event-related potential (ERP) technology has been used to address this issue. The feedback-related negativity (FRN) component of ERPs has been studied intensively with the averaged linked mastoid reference method (LM). However, it is unknown whether FRN can be induced by an expectancy violation in an antonym relations context and whether LM is the most suitable reference approach. To address these issues, the current research directly compared the ERP components induced by expectancy violations in antonym expectation and gambling tasks with a within-subjects design and investigated the effect of the reference approach on the experimental effects. Specifically, we systematically compared the influence of the LM, reference electrode standardization technique (REST) and average reference (AVE) approaches on the amplitude, scalp distribution and magnitude of ERP effects as a function of expectancy violation type. The expectancy deviation in the antonym expectation task elicited an N400 effect that differed from the FRN effect induced in the gambling task; this difference was confirmed by all the three reference methods. Both the amplitudes of the ERP effects (N400 and FRN) and the magnitude as the expectancy violation increased were greater under the LM approach than those under the REST approach, followed by those under the AVE approach. Based on the statistical results, the electrode sites that showed the N400 and FRN effects critically depended on the reference method, and the results of the REST analysis were consistent with previous ERP studies. Combined with evidence from simulation studies, we suggest that REST is an optional reference method to be used in future ERP data analysis. PMID:29615858

  19. Committee on Diabetes Mellitus Indices of the Japan Society of Clinical Chemistry-recommended reference measurement procedure and reference materials for glycated albumin determination.

    PubMed

    Takei, Izumi; Hoshino, Tadao; Tominaga, Makoto; Ishibashi, Midori; Kuwa, Katsuhiko; Umemoto, Masao; Tani, Wataru; Okahashi, Mikiko; Yasukawa, Keiko; Kohzuma, Takuji; Sato, Asako

    2016-01-01

    Glycated albumin is an intermediate glycaemic control marker for which there are several measurement procedures with entirely different reference intervals. We have developed a reference measurement procedure for the purpose of standardizing glycated albumin measurements. The isotope dilution liquid chromatography/tandem mass spectrometry method was developed as a reference measurement procedure for glycated albumin. The stable isotopes of lysine and fructosyl-lysine, which serve as an internal standard, were added to albumin isolated from serum, followed by hydrogenation. After hydrolysis of albumin with hot hydrochloric acid, the liberated lysine and fructosyl-lysine were measured by liquid chromatography/tandem mass spectrometry, and their concentrations were determined from each isotope ratio. The reference materials (JCCRM611) for determining of glycated albumin were prepared from pooled patient blood samples. The isotope dilution-tandem mass spectrometry calibration curve of fructosyl-lysine and lysine showed good linearity (r = 0.999). The inter-assay and intra-assay coefficient of variation values of glycated albumin measurement were 1.2 and 1.4%, respectively. The glycated albumin values of serum in patients with diabetes assessed through the use of this method showed a good relationship with routine measurement procedures (r = 0.997). The relationship of glycated albumin values of the reference material (JCCRM611) between these two methods was the same as the relationship with the patient serum samples. The Committee on Diabetes Mellitus Indices of the Japan Society of Clinical Chemistry recommends the isotope dilution liquid chromatography/tandem mass spectrometry method as a reference measurement procedure, and JCCRM611 as a certified reference material for glycated albumin measurement. In addition, we recommend the traceability system for glycated albumin measurement. © The Author(s) 2015.

  20. Reference Values for Spirometry Derived Using Lambda, Mu, Sigma (LMS) Method in Korean Adults: in Comparison with Previous References.

    PubMed

    Jo, Bum Seak; Myong, Jun Pyo; Rhee, Chin Kook; Yoon, Hyoung Kyu; Koo, Jung Wan; Kim, Hyoung Ryoul

    2018-01-15

    The present study aimed to update the prediction equations for spirometry and their lower limits of normal (LLN) by using the lambda, mu, sigma (LMS) method and to compare the outcomes with the values of previous spirometric reference equations. Spirometric data of 10,249 healthy non-smokers (8,776 females) were extracted from the fourth and fifth versions of the Korea National Health and Nutrition Examination Survey (KNHANES IV, 2007-2009; V, 2010-2012). Reference equations were derived using the LMS method which allows modeling skewness (lambda [L]), mean (mu [M]), and coefficient of variation (sigma [S]). The outcome equations were compared with previous reference values. Prediction equations were presented in the following form: predicted value = e{a + b × ln(height) + c × ln(age) + M - spline}. The new predicted values for spirometry and their LLN derived using the LMS method were shown to more accurately reflect transitions in pulmonary function in young adults than previous prediction equations derived using conventional regression analysis in 2013. There were partial discrepancies between the new reference values and the reference values from the Global Lung Function Initiative in 2012. The results should be interpreted with caution for young adults and elderly males, particularly in terms of the LLN for forced expiratory volume in one second/forced vital capacity in elderly males. Serial spirometry follow-up, together with correlations with other clinical findings, should be emphasized in evaluating the pulmonary function of individuals. Future studies are needed to improve the accuracy of reference data and to develop continuous reference values for spirometry across all ages. © 2018 The Korean Academy of Medical Sciences.

  1. An Optimal Control Modification to Model-Reference Adaptive Control for Fast Adaptation

    NASA Technical Reports Server (NTRS)

    Nguyen, Nhan T.; Krishnakumar, Kalmanje; Boskovic, Jovan

    2008-01-01

    This paper presents a method that can achieve fast adaptation for a class of model-reference adaptive control. It is well-known that standard model-reference adaptive control exhibits high-gain control behaviors when a large adaptive gain is used to achieve fast adaptation in order to reduce tracking error rapidly. High gain control creates high-frequency oscillations that can excite unmodeled dynamics and can lead to instability. The fast adaptation approach is based on the minimization of the squares of the tracking error, which is formulated as an optimal control problem. The necessary condition of optimality is used to derive an adaptive law using the gradient method. This adaptive law is shown to result in uniform boundedness of the tracking error by means of the Lyapunov s direct method. Furthermore, this adaptive law allows a large adaptive gain to be used without causing undesired high-gain control effects. The method is shown to be more robust than standard model-reference adaptive control. Simulations demonstrate the effectiveness of the proposed method.

  2. SU-G-BRB-14: Uncertainty of Radiochromic Film Based Relative Dose Measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Devic, S; Tomic, N; DeBlois, F

    2016-06-15

    Purpose: Due to inherently non-linear dose response, measurement of relative dose distribution with radiochromic film requires measurement of absolute dose using a calibration curve following previously established reference dosimetry protocol. On the other hand, a functional form that converts the inherently non-linear dose response curve of the radiochromic film dosimetry system into linear one has been proposed recently [Devic et al, Med. Phys. 39 4850–4857 (2012)]. However, there is a question what would be the uncertainty of such measured relative dose. Methods: If the relative dose distribution is determined going through the reference dosimetry system (conversion of the response bymore » using calibration curve into absolute dose) the total uncertainty of such determined relative dose will be calculated by summing in quadrature total uncertainties of doses measured at a given and at the reference point. On the other hand, if the relative dose is determined using linearization method, the new response variable is calculated as ζ=a(netOD)n/ln(netOD). In this case, the total uncertainty in relative dose will be calculated by summing in quadrature uncertainties for a new response function (σζ) for a given and the reference point. Results: Except at very low doses, where the measurement uncertainty dominates, the total relative dose uncertainty is less than 1% for the linear response method as compared to almost 2% uncertainty level for the reference dosimetry method. The result is not surprising having in mind that the total uncertainty of the reference dose method is dominated by the fitting uncertainty, which is mitigated in the case of linearization method. Conclusion: Linearization of the radiochromic film dose response provides a convenient and a more precise method for relative dose measurements as it does not require reference dosimetry and creation of calibration curve. However, the linearity of the newly introduced function must be verified. Dave Lewis is inventor and runs a consulting company for radiochromic films.« less

  3. Standardization in laboratory medicine: Adoption of common reference intervals to the Croatian population.

    PubMed

    Flegar-Meštrić, Zlata; Perkov, Sonja; Radeljak, Andrea

    2016-03-26

    Considering the fact that the results of laboratory tests provide useful information about the state of health of patients, determination of reference value is considered an intrinsic part in the development of laboratory medicine. There are still huge differences in the analytical methods used as well as in the associated reference intervals which could consequently significantly affect the proper assessment of patient health. In a constant effort to increase the quality of patients' care, there are numerous international initiatives for standardization and/or harmonization of laboratory diagnostics in order to achieve maximum comparability of laboratory test results and improve patient safety. Through the standardization and harmonization processes of analytical methods the ability to create unique reference intervals is achieved. Such reference intervals could be applied globally in all laboratories using methods traceable to the same reference measuring system and analysing the biological samples from the populations with similar socio-demographic and ethnic characteristics. In this review we outlined the results of the harmonization processes in Croatia in the field of population based reference intervals for clinically relevant blood and serum constituents which are in accordance with ongoing activity for worldwide standardization and harmonization based on traceability in laboratory medicine.

  4. [Establishing biological reference intervals of alanine transaminase for clinical laboratory stored database].

    PubMed

    Guo, Wei; Song, Binbin; Shen, Junfei; Wu, Jiong; Zhang, Chunyan; Wang, Beili; Pan, Baishen

    2015-08-25

    To establish an indirect reference interval based on the test results of alanine aminotransferase stored in a laboratory information system. All alanine aminotransferase results were included for outpatients and physical examinations that were stored in the laboratory information system of Zhongshan Hospital during 2014. The original data were transformed using a Box-Cox transformation to obtain an approximate normal distribution. Outliers were identified and omitted using the Chauvenet and Tukey methods. The indirect reference intervals were obtained by simultaneously applying nonparametric and Hoffmann methods. The reference change value was selected to determine the statistical significance of the observed differences between the calculated and published reference intervals. The indirect reference intervals for alanine aminotransferase of all groups were 12 to 41 U/L (male, outpatient), 12 to 48 U/L (male, physical examination), 9 to 32 U/L (female, outpatient), and 8 to 35 U/L (female, physical examination), respectively. The absolute differences when compared with the direct results were all smaller than the reference change value of alanine aminotransferase. The Box-Cox transformation combined with the Hoffmann and Tukey methods is a simple and reliable technique that should be promoted and used by clinical laboratories.

  5. Standardization in laboratory medicine: Adoption of common reference intervals to the Croatian population

    PubMed Central

    Flegar-Meštrić, Zlata; Perkov, Sonja; Radeljak, Andrea

    2016-01-01

    Considering the fact that the results of laboratory tests provide useful information about the state of health of patients, determination of reference value is considered an intrinsic part in the development of laboratory medicine. There are still huge differences in the analytical methods used as well as in the associated reference intervals which could consequently significantly affect the proper assessment of patient health. In a constant effort to increase the quality of patients’ care, there are numerous international initiatives for standardization and/or harmonization of laboratory diagnostics in order to achieve maximum comparability of laboratory test results and improve patient safety. Through the standardization and harmonization processes of analytical methods the ability to create unique reference intervals is achieved. Such reference intervals could be applied globally in all laboratories using methods traceable to the same reference measuring system and analysing the biological samples from the populations with similar socio-demographic and ethnic characteristics. In this review we outlined the results of the harmonization processes in Croatia in the field of population based reference intervals for clinically relevant blood and serum constituents which are in accordance with ongoing activity for worldwide standardization and harmonization based on traceability in laboratory medicine. PMID:27019800

  6. Evaluation of methods for the assay of radium-228 in water

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Noyce, J.R.

    1981-02-01

    The technical literature from 1967 to May 1980 was searched for methods for assaying radium-228 in water. These methods were evaluated for their suitability as potential EPA reference methods for drinking water assays. The authors suggest the present EPA reference method (Krieger, 1976) be retained but improved, and a second method (McCurdy and Mellor, 1979), which employs beta-gamma coincidence counting, be added. Included in this report is a table that lists the principal features of 17 methods for radium-228 assays.

  7. Coordinate references for the indoor/outdoor seamless positioning

    NASA Astrophysics Data System (ADS)

    Ruan, Ling; Zhang, Ling; Long, Yi; Cheng, Fei

    2018-05-01

    Indoor positioning technologies are being developed rapidly, and seamless positioning which connected indoor and outdoor space is a new trend. The indoor and outdoor positioning are not applying the same coordinate system and different indoor positioning scenes uses different indoor local coordinate reference systems. A specific and unified coordinate reference frame is needed as the space basis and premise in seamless positioning application. Trajectory analysis of indoor and outdoor integration also requires a uniform coordinate reference. However, the coordinate reference frame in seamless positioning which can applied to various complex scenarios is lacking of research for a long time. In this paper, we proposed a universal coordinate reference frame in indoor/outdoor seamless positioning. The research focus on analysis and classify the indoor positioning scenes and put forward the coordinate reference system establishment and coordinate transformation methods in each scene. And, through some experiments, the calibration method feasibility was verified.

  8. Systems and methods that generate height map models for efficient three dimensional reconstruction from depth information

    DOEpatents

    Frahm, Jan-Michael; Pollefeys, Marc Andre Leon; Gallup, David Robert

    2015-12-08

    Methods of generating a three dimensional representation of an object in a reference plane from a depth map including distances from a reference point to pixels in an image of the object taken from a reference point. Weights are assigned to respective voxels in a three dimensional grid along rays extending from the reference point through the pixels in the image based on the distances in the depth map from the reference point to the respective pixels, and a height map including an array of height values in the reference plane is formed based on the assigned weights. An n-layer height map may be constructed by generating a probabilistic occupancy grid for the voxels and forming an n-dimensional height map comprising an array of layer height values in the reference plane based on the probabilistic occupancy grid.

  9. A series of strategies for solving the shortage of reference standards for multi-components determination of traditional Chinese medicine, Mahoniae Caulis as a case.

    PubMed

    Wang, Wenguang; Ma, Xiaoli; Guo, Xiaoyu; Zhao, Mingbo; Tu, Pengfei; Jiang, Yong

    2015-09-18

    In order to solve the bottleneck of reference standards shortage for comprehensive quality control of traditional Chinese medicines (TCMs), a series of strategies, including one single reference standard to determine multi-compounds (SSDMC), quantitative analysis by standardized reference extract (QASRE), and quantitative nuclear magnetic resonance spectroscopy (qNMR) were proposed, and Mahoniae Caulis was selected as an example to develop and validate these methods for simultaneous determination of four alkaloids, columbamine, jatrorrhizine, palmatine, and berberine. Comprehensive comparisons among these methods and with the conventional external standard method (ESM) were carried out. The relative expanded uncertainty of measurement was firstly used to compare their credibility. The results showed that all these three new developed methods can accurately accomplish the quantification by using only one purified reference standard, but each of them has its own advantages and disadvantages as well as the specific application scope, which were also discussed in detail in this paper. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. SUPPORT FOR REFERENCE AND EQUIVALENCY PROGRAM

    EPA Science Inventory

    Federal Reference Methods (FRMs) and Federal Equivalent Methods (FEMs) form the backbone of the EPA's national monitoring strategy. They are the measurement methodologies that define attainment of a National Ambient Air Quality Standard (NAAQS). As knowledge and technology adva...

  11. Measurement of the depth of narrow slotted sections in eddy current reference standards

    NASA Astrophysics Data System (ADS)

    Kim, Young-Joo; Kim, Young-gil; Ahn, Bongyoung; Yoon, Dong-Jin

    2007-02-01

    The dimensions of the slots in eddy current (EC) reference standards are too narrow to be measured by general depth measurement methods such as the optical (laser) or stylus methods. However, measurement of the dimensions of the machined slots is a prerequisite to using the blocks as references. The present paper suggests a measurement method for the slotted section using an ultrasonic test. The width and depth of the slots measured in our study are roughly 0.1 mm and 0.5 mm, respectively. The time of flight (TOF) of the ultrasonic wave was measured precisely. The ultrasonic velocity in the material of the EC reference standard was calculated with the measured values of the TOF and its thickness. Reflected waves from the tip of the slot and the bottom surface of the EC standard were successfully classified. Using this method we have successfully determined the depth of the slotted section.

  12. Ballistocardiogram Artifact Removal with a Reference Layer and Standard EEG Cap

    PubMed Central

    Luo, Qingfei; Huang, Xiaoshan; Glover, Gary H.

    2014-01-01

    Background In simultaneous EEG-fMRI, the EEG recordings are severely contaminated by ballistocardiogram (BCG) artifacts, which are caused by cardiac pulsations. To reconstruct and remove the BCG artifacts, one promising method is to measure the artifacts in the absence of EEG signal by placing a group of electrodes (BCG electrodes) on a conductive layer (reference layer) insulated from the scalp. However, current BCG reference layer (BRL) methods either use a customized EEG cap composed of electrode pairs, or need to construct the custom reference layer through additional model-building experiments for each EEG-fMRI experiment. These requirements have limited the versatility and efficiency of BRL. The aim of this study is to propose a more practical and efficient BRL method and compare its performance with the most popular BCG removal method, the optimal basis sets (OBS) algorithm. New Method By designing the reference layer as a permanent and reusable cap, the new BRL method is able to be used with a standard EEG cap, and no extra experiments and preparations are needed to use the BRL in an EEG-fMRI experiment. Results The BRL method effectively removed the BCG artifacts from both oscillatory and evoked potential scalp recordings and recovered the EEG signal. Comparison with Existing Method Compared to the OBS, this new BRL method improved the contrast-to-noise ratios of the alpha-wave, visual, and auditory evoked potential signals by 101%, 76%, and 75% respectively, employing 160 BCG electrodes. Using only 20 BCG electrodes, the BRL improved the EEG signal by 74%/26%/41% respectively. Conclusion The proposed method can substantially improve the EEG signal quality compared with traditional methods. PMID:24960423

  13. Note: Improved calibration of atomic force microscope cantilevers using multiple reference cantilevers.

    PubMed

    Sader, John E; Friend, James R

    2015-05-01

    Overall precision of the simplified calibration method in J. E. Sader et al., Rev. Sci. Instrum. 83, 103705 (2012), Sec. III D, is dominated by the spring constant of the reference cantilever. The question arises: How does one take measurements from multiple reference cantilevers, and combine these results, to improve uncertainty of the reference cantilever's spring constant and hence the overall precision of the method? This question is addressed in this note. Its answer enables manufacturers to specify of a single set of data for the spring constant, resonant frequency, and quality factor, from measurements on multiple reference cantilevers. With this data set, users can trivially calibrate cantilevers of the same type.

  14. Direct-to-digital holography and holovision

    DOEpatents

    Thomas, Clarence E.; Baylor, Larry R.; Hanson, Gregory R.; Rasmussen, David A.; Voelkl, Edgar; Castracane, James; Simkulet, Michelle; Clow, Lawrence

    2000-01-01

    Systems and methods for direct-to-digital holography are described. An apparatus includes a laser; a beamsplitter optically coupled to the laser; a reference beam mirror optically coupled to the beamsplitter; an object optically coupled to the beamsplitter, a focusing lens optically coupled to both the reference beam mirror and the object; and a digital recorder optically coupled to the focusing lens. A reference beam is incident upon the reference beam mirror at a non-normal angle, and the reference beam and an object beam are focused by the focusing lens at a focal plane of the digital recorder to form an image. The systems and methods provide advantages in that computer assisted holographic measurements can be made.

  15. Virtual mask digital electron beam lithography

    DOEpatents

    Baylor, L.R.; Thomas, C.E.; Voelkl, E.; Moore, J.A.; Simpson, M.L.; Paulus, M.J.

    1999-04-06

    Systems and methods for direct-to-digital holography are described. An apparatus includes a laser; a beamsplitter optically coupled to the laser; a reference beam mirror optically coupled to the beamsplitter; an object optically coupled to the beamsplitter, a focusing lens optically coupled to both the reference beam mirror and the object; and a digital recorder optically coupled to the focusing lens. A reference beam is incident upon the reference beam mirror at a non-normal angle, and the reference beam and an object beam are focused by the focusing lens at a focal plane of the digital recorder to form an image. The systems and methods provide advantages in that computer assisted holographic measurements can be made. 5 figs.

  16. Virtual mask digital electron beam lithography

    DOEpatents

    Baylor, Larry R.; Thomas, Clarence E.; Voelkl, Edgar; Moore, James A.; Simpson, Michael L.; Paulus, Michael J.

    1999-01-01

    Systems and methods for direct-to-digital holography are described. An apparatus includes a laser; a beamsplitter optically coupled to the laser; a reference beam mirror optically coupled to the beamsplitter; an object optically coupled to the beamsplitter, a focusing lens optically coupled to both the reference beam mirror and the object; and a digital recorder optically coupled to the focusing lens. A reference beam is incident upon the reference beam mirror at a non-normal angle, and the reference beam and an object beam are focused by the focusing lens at a focal plane of the digital recorder to form an image. The systems and methods provide advantages in that computer assisted holographic measurements can be made.

  17. User Education in the Academic Library: Media Methods for Reference Work. An Annotated Bibliography. Updated.

    ERIC Educational Resources Information Center

    Wharton, Sika

    This annotated bibliography focuses on academic library usage of audiovisual (AV) methods of instruction, particularly for the enhancement of the reference teaching function. The bibliography's objectives are as follows: to identify current trends with regard to AV methods in library orientation and bibliographic instruction; to isolate instances…

  18. 40 CFR 63.805 - Performance test methods.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Collection of Coating and Ink Samples for VOC Content Analysis by Reference Method 24 and Reference Method... determine the VHAP content of the liquid coating. Formulation data shall be used to identify VHAP present in... the solids content by weight and the density of coatings. If it is demonstrated to the satisfaction of...

  19. Diffuse reflectance spectrophotometry with visible light: comparison of four different methods in a tissue phantom

    NASA Astrophysics Data System (ADS)

    Gade, John; Palmqvist, Dorte; Plomgård, Peter; Greisen, Gorm

    2006-01-01

    The purpose of the study was to compare algorithms of four methods (plus two modifications) for spectrophotometric haemoglobin saturation measurements. Comparison was made in tissue phantoms basically consisting of a phosphate buffer, Intralipid and blood, allowing samples to be taken for reference measurements. Three experimental series were made. In experiment A (eight phantoms) we used the Knoefel method and measured specific extinction coefficients with a reflection spectrophotometer. In experiment B (six phantoms) the fully oxygenated phantoms were gradually deoxygenated with baker's yeast, and simultaneous measurements were made with our spectrophotometer and with a reference oxymeter (ABL-605) in 3 min intervals. For each spectrophotometric measurement haemoglobin saturation was calculated with all algorithms and modifications, and compared with reference. In experiment C (11 phantoms) we evaluated the ability of a modification of the Knoefel method to measure haemoglobin concentration in absolute quantities using extinction coefficients from experiment A. Results. Experiment A: with the Knoefel method extinction coefficients (±SD) for oxyhaemoglobin at 553.04 and 573.75 nm were 1.117 (±0.0396) ODmM-1 and 1.680 (± 0.0815) ODmM-1, respectively, and for deoxyhaemoglobin 1.205 (± 0.0514) ODmM-1 and 0.953 (±0.0487) ODmM-1, respectively. Experiment B: high correlation with the reference was found in all methods (r = 0.94-0.97). However, agreement varied from evidently wrong in method 3 and the original method 4 (e.g. saturation above 160%) to high agreement in method 2 as well as the modifications of methods 1 and 4, where oxygen dissociation curves were close to the reference method. Experiment C: with the modified Knoefel method the mean haemoglobin concentration difference from reference was 8.3% and the correlation was high (r = 0.91). We conclude that method 2 and the modifications of 1 and 4 were superior to the others, but depended on known values in the same or similar phantoms. The original method 1 was independent of results from the tissue phantoms, but agreement was slightly poorer. Method 3 and the original method 4 could not be recommended. The ability of the modified method 1 to measure haemoglobin concentration is promising, but needs further development.

  20. Applications of asymptotic confidence intervals with continuity corrections for asymmetric comparisons in noninferiority trials.

    PubMed

    Soulakova, Julia N; Bright, Brianna C

    2013-01-01

    A large-sample problem of illustrating noninferiority of an experimental treatment over a referent treatment for binary outcomes is considered. The methods of illustrating noninferiority involve constructing the lower two-sided confidence bound for the difference between binomial proportions corresponding to the experimental and referent treatments and comparing it with the negative value of the noninferiority margin. The three considered methods, Anbar, Falk-Koch, and Reduced Falk-Koch, handle the comparison in an asymmetric way, that is, only the referent proportion out of the two, experimental and referent, is directly involved in the expression for the variance of the difference between two sample proportions. Five continuity corrections (including zero) are considered with respect to each approach. The key properties of the corresponding methods are evaluated via simulations. First, the uncorrected two-sided confidence intervals can, potentially, have smaller coverage probability than the nominal level even for moderately large sample sizes, for example, 150 per group. Next, the 15 testing methods are discussed in terms of their Type I error rate and power. In the settings with a relatively small referent proportion (about 0.4 or smaller), the Anbar approach with Yates' continuity correction is recommended for balanced designs and the Falk-Koch method with Yates' correction is recommended for unbalanced designs. For relatively moderate (about 0.6) and large (about 0.8 or greater) referent proportion, the uncorrected Reduced Falk-Koch method is recommended, although in this case, all methods tend to be over-conservative. These results are expected to be used in the design stage of a noninferiority study when asymmetric comparisons are envisioned. Copyright © 2013 John Wiley & Sons, Ltd.

  1. Methods, systems and apparatus for controlling third harmonic voltage when operating a multi-space machine in an overmodulation region

    DOEpatents

    Perisic, Milun; Kinoshita, Michael H; Ranson, Ray M; Gallegos-Lopez, Gabriel

    2014-06-03

    Methods, system and apparatus are provided for controlling third harmonic voltages when operating a multi-phase machine in an overmodulation region. The multi-phase machine can be, for example, a five-phase machine in a vector controlled motor drive system that includes a five-phase PWM controlled inverter module that drives the five-phase machine. Techniques for overmodulating a reference voltage vector are provided. For example, when the reference voltage vector is determined to be within the overmodulation region, an angle of the reference voltage vector can be modified to generate a reference voltage overmodulation control angle, and a magnitude of the reference voltage vector can be modified, based on the reference voltage overmodulation control angle, to generate a modified magnitude of the reference voltage vector. By modifying the reference voltage vector, voltage command signals that control a five-phase inverter module can be optimized to increase output voltages generated by the five-phase inverter module.

  2. A Method for Evaluating Outcomes of Restoration When No Reference Sites Exist

    Treesearch

    J. Stephen Brewer; Timothy Menzel

    2009-01-01

    Ecological restoration typically seeks to shift species composition toward that of existing reference sites. Yet, comparing the assemblages in restored and reference habitats assumes that similarity to the reference habitat is the optimal outcome of restoration and does not provide a perspective on regionally rare off-site species. When no such reference assemblages of...

  3. Application of quantitative 1H NMR for the calibration of protoberberine alkaloid reference standards.

    PubMed

    Wu, Yan; He, Yi; He, Wenyi; Zhang, Yumei; Lu, Jing; Dai, Zhong; Ma, Shuangcheng; Lin, Ruichao

    2014-03-01

    Quantitative nuclear magnetic resonance spectroscopy (qNMR) has been developed into an important tool in the drug analysis, biomacromolecule detection, and metabolism study. Compared with mass balance method, qNMR method bears some advantages in the calibration of reference standard (RS): it determines the absolute amount of a sample; other chemical compound and its certified reference material (CRM) can be used as internal standard (IS) to obtain the purity of the sample. Protoberberine alkaloids have many biological activities and have been used as reference standards for the control of many herbal drugs. In present study, the qNMR methods were developed for the calibration of berberine hydrochloride, palmatine hydrochloride, tetrahydropalmatine, and phellodendrine hydrochloride with potassium hydrogen phthalate as IS. Method validation was carried out according to the guidelines for the method validation of Chinese Pharmacopoeia. The results of qNMR were compared with those of mass balance method and the differences between the results of two methods were acceptable based on the analysis of estimated measurement uncertainties. Therefore, qNMR is an effective and reliable analysis method for the calibration of RS and can be used as a good complementarity to the mass balance method. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. The use of digital PCR to improve the application of quantitative molecular diagnostic methods for tuberculosis.

    PubMed

    Devonshire, Alison S; O'Sullivan, Denise M; Honeyborne, Isobella; Jones, Gerwyn; Karczmarczyk, Maria; Pavšič, Jernej; Gutteridge, Alice; Milavec, Mojca; Mendoza, Pablo; Schimmel, Heinz; Van Heuverswyn, Fran; Gorton, Rebecca; Cirillo, Daniela Maria; Borroni, Emanuele; Harris, Kathryn; Barnard, Marinus; Heydenrych, Anthenette; Ndusilo, Norah; Wallis, Carole L; Pillay, Keshree; Barry, Thomas; Reddington, Kate; Richter, Elvira; Mozioğlu, Erkan; Akyürek, Sema; Yalçınkaya, Burhanettin; Akgoz, Muslum; Žel, Jana; Foy, Carole A; McHugh, Timothy D; Huggett, Jim F

    2016-08-03

    Real-time PCR (qPCR) based methods, such as the Xpert MTB/RIF, are increasingly being used to diagnose tuberculosis (TB). While qualitative methods are adequate for diagnosis, the therapeutic monitoring of TB patients requires quantitative methods currently performed using smear microscopy. The potential use of quantitative molecular measurements for therapeutic monitoring has been investigated but findings have been variable and inconclusive. The lack of an adequate reference method and reference materials is a barrier to understanding the source of such disagreement. Digital PCR (dPCR) offers the potential for an accurate method for quantification of specific DNA sequences in reference materials which can be used to evaluate quantitative molecular methods for TB treatment monitoring. To assess a novel approach for the development of quality assurance materials we used dPCR to quantify specific DNA sequences in a range of prototype reference materials and evaluated accuracy between different laboratories and instruments. The materials were then also used to evaluate the quantitative performance of qPCR and Xpert MTB/RIF in eight clinical testing laboratories. dPCR was found to provide results in good agreement with the other methods tested and to be highly reproducible between laboratories without calibration even when using different instruments. When the reference materials were analysed with qPCR and Xpert MTB/RIF by clinical laboratories, all laboratories were able to correctly rank the reference materials according to concentration, however there was a marked difference in the measured magnitude. TB is a disease where the quantification of the pathogen could lead to better patient management and qPCR methods offer the potential to rapidly perform such analysis. However, our findings suggest that when precisely characterised materials are used to evaluate qPCR methods, the measurement result variation is too high to determine whether molecular quantification of Mycobacterium tuberculosis would provide a clinically useful readout. The methods described in this study provide a means by which the technical performance of quantitative molecular methods can be evaluated independently of clinical variability to improve accuracy of measurement results. These will assist in ultimately increasing the likelihood that such approaches could be used to improve patient management of TB.

  5. Effect of reference genome selection on the performance of computational methods for genome-wide protein-protein interaction prediction.

    PubMed

    Muley, Vijaykumar Yogesh; Ranjan, Akash

    2012-01-01

    Recent progress in computational methods for predicting physical and functional protein-protein interactions has provided new insights into the complexity of biological processes. Most of these methods assume that functionally interacting proteins are likely to have a shared evolutionary history. This history can be traced out for the protein pairs of a query genome by correlating different evolutionary aspects of their homologs in multiple genomes known as the reference genomes. These methods include phylogenetic profiling, gene neighborhood and co-occurrence of the orthologous protein coding genes in the same cluster or operon. These are collectively known as genomic context methods. On the other hand a method called mirrortree is based on the similarity of phylogenetic trees between two interacting proteins. Comprehensive performance analyses of these methods have been frequently reported in literature. However, very few studies provide insight into the effect of reference genome selection on detection of meaningful protein interactions. We analyzed the performance of four methods and their variants to understand the effect of reference genome selection on prediction efficacy. We used six sets of reference genomes, sampled in accordance with phylogenetic diversity and relationship between organisms from 565 bacteria. We used Escherichia coli as a model organism and the gold standard datasets of interacting proteins reported in DIP, EcoCyc and KEGG databases to compare the performance of the prediction methods. Higher performance for predicting protein-protein interactions was achievable even with 100-150 bacterial genomes out of 565 genomes. Inclusion of archaeal genomes in the reference genome set improves performance. We find that in order to obtain a good performance, it is better to sample few genomes of related genera of prokaryotes from the large number of available genomes. Moreover, such a sampling allows for selecting 50-100 genomes for comparable accuracy of predictions when computational resources are limited.

  6. In-house validation study of the DuPont Qualicon BAX system Q7 instrument with the BAX system PCR Assay for Salmonella (modification of AOAC Official Method 2003.09 and AOAC Research Institute Performance-Tested Method 100201).

    PubMed

    Tice, George; Andaloro, Bridget; White, H Kirk; Bolton, Lance; Wang, Siqun; Davis, Eugene; Wallace, Morgan

    2009-01-01

    In 2006, DuPont Qualicon introduced the BAX system Q7 instrument for use with its assays. To demonstrate the equivalence of the new and old instruments, a validation study was conducted using the BAX system PCR Assay for Salmonella, AOAC Official Method 2003.09, on three food types. The foods were simultaneously analyzed with the BAX system Q7 instrument and either the U.S. Food and Drug Administration Bacteriological Analytical Manual or the U.S. Department of Agriculture-Food Safety and Inspection Service Microbiology Laboratory Guidebook reference method for detecting Salmonella. Comparable performance between the BAX system and the reference methods was observed. Of the 75 paired samples analyzed, 39 samples were positive by both the BAX system and reference methods, and 36 samples were negative by both the BAX system and reference methods, demonstrating 100% correlation. Inclusivity and exclusivity for the BAX system Q7 instrument were also established by testing 50 Salmonella strains and 20 non-Salmonella isolates. All Salmonella strains returned positive results, and all non-Salmonella isolates returned a negative response.

  7. A frequency domain global parameter estimation method for multiple reference frequency response measurements

    NASA Astrophysics Data System (ADS)

    Shih, C. Y.; Tsuei, Y. G.; Allemang, R. J.; Brown, D. L.

    1988-10-01

    A method of using the matrix Auto-Regressive Moving Average (ARMA) model in the Laplace domain for multiple-reference global parameter identification is presented. This method is particularly applicable to the area of modal analysis where high modal density exists. The method is also applicable when multiple reference frequency response functions are used to characterise linear systems. In order to facilitate the mathematical solution, the Forsythe orthogonal polynomial is used to reduce the ill-conditioning of the formulated equations and to decouple the normal matrix into two reduced matrix blocks. A Complex Mode Indicator Function (CMIF) is introduced, which can be used to determine the proper order of the rational polynomials.

  8. The development of a revised version of multi-center molecular Ornstein-Zernike equation

    NASA Astrophysics Data System (ADS)

    Kido, Kentaro; Yokogawa, Daisuke; Sato, Hirofumi

    2012-04-01

    Ornstein-Zernike (OZ)-type theory is a powerful tool to obtain 3-dimensional solvent distribution around solute molecule. Recently, we proposed multi-center molecular OZ method, which is suitable for parallel computing of 3D solvation structure. The distribution function in this method consists of two components, namely reference and residue parts. Several types of the function were examined as the reference part to investigate the numerical robustness of the method. As the benchmark, the method is applied to water, benzene in aqueous solution and single-walled carbon nanotube in chloroform solution. The results indicate that fully-parallelization is achieved by utilizing the newly proposed reference functions.

  9. Application of solid/liquid extraction for the gravimetric determination of lipids in royal jelly.

    PubMed

    Antinelli, Jean-François; Davico, Renée; Rognone, Catherine; Faucon, Jean-Paul; Lizzani-Cuvelier, Louisette

    2002-04-10

    Gravimetric lipid determination is a major parameter for the characterization and the authentication of royal jelly quality. A solid/liquid extraction was compared to the reference method, which is based on liquid/liquid extraction. The amount of royal jelly and the time of the extraction were optimized in comparison to the reference method. Boiling/rinsing ratio and spread of royal jelly onto the extraction thimble were identified as critical parameters, resulting in good accuracy and precision for the alternative method. Comparison of reproducibility and repeatability of both methods associated with gas chromatographic analysis of the composition of the extracted lipids showed no differences between the two methods. As the intra-laboratory validation tests were comparable to the reference method, while offering rapidity and a decrease in amount of solvent used, it was concluded that the proposed method should be used with no modification of quality criteria and norms established for royal jelly characterization.

  10. Method and Apparatus for Non-Invasive Measurement of Changes in Intracranial Pressure

    NASA Technical Reports Server (NTRS)

    Yost, William T. (Inventor); Cantrell, John H., Jr. (Inventor)

    2004-01-01

    A method and apparatus for measuring intracranial pressure. In one embodiment, the method comprises the steps of generating an information signal that comprises components (e.g., pulsatile changes and slow changes) that are related to intracranial pressure and blood pressure, generating a reference signal comprising pulsatile components that are solely related to blood pressure, processing the information and reference signals to determine the pulsatile components of the information signal that have generally the same phase as the pulsatile components of the reference signal, and removing from the information signal the pulsatile components determined to have generally the same phase as the pulsatile components of the reference signal so as to provide a data signal having components wherein substantially all of the components are related to intracranial pressure.

  11. Reference Intervals of Common Clinical Chemistry Analytes for Adults in Hong Kong.

    PubMed

    Lo, Y C; Armbruster, David A

    2012-04-01

    Defining reference intervals is a major challenge because of the difficulty in recruiting volunteers to participate and testing samples from a significant number of healthy reference individuals. Historical literature citation intervals are often suboptimal because they're be based on obsolete methods and/or only a small number of poorly defined reference samples. Blood donors in Hong Kong gave permission for additional blood to be collected for reference interval testing. The samples were tested for twenty-five routine analytes on the Abbott ARCHITECT clinical chemistry system. Results were analyzed using the Rhoads EP evaluator software program, which is based on the CLSI/IFCC C28-A guideline, and defines the reference interval as the 95% central range. Method specific reference intervals were established for twenty-five common clinical chemistry analytes for a Chinese ethnic population. The intervals were defined for each gender separately and for genders combined. Gender specific or combined gender intervals were adapted as appropriate for each analyte. A large number of healthy, apparently normal blood donors from a local ethnic population were tested to provide current reference intervals for a new clinical chemistry system. Intervals were determined following an accepted international guideline. Laboratories using the same or similar methodologies may adapt these intervals if deemed validated and deemed suitable for their patient population. Laboratories using different methodologies may be able to successfully adapt the intervals for their facilities using the reference interval transference technique based on a method comparison study.

  12. The NIH analytical methods and reference materials program for dietary supplements.

    PubMed

    Betz, Joseph M; Fisher, Kenneth D; Saldanha, Leila G; Coates, Paul M

    2007-09-01

    Quality of botanical products is a great uncertainty that consumers, clinicians, regulators, and researchers face. Definitions of quality abound, and include specifications for sanitation, adventitious agents (pesticides, metals, weeds), and content of natural chemicals. Because dietary supplements (DS) are often complex mixtures, they pose analytical challenges and method validation may be difficult. In response to product quality concerns and the need for validated and publicly available methods for DS analysis, the US Congress directed the Office of Dietary Supplements (ODS) at the National Institutes of Health (NIH) to accelerate an ongoing methods validation process, and the Dietary Supplements Methods and Reference Materials Program was created. The program was constructed from stakeholder input and incorporates several federal procurement and granting mechanisms in a coordinated and interlocking framework. The framework facilitates validation of analytical methods, analytical standards, and reference materials.

  13. Collaborative derivation of reference intervals for major clinical laboratory tests in Japan.

    PubMed

    Ichihara, Kiyoshi; Yomamoto, Yoshikazu; Hotta, Taeko; Hosogaya, Shigemi; Miyachi, Hayato; Itoh, Yoshihisa; Ishibashi, Midori; Kang, Dongchon

    2016-05-01

    Three multicentre studies of reference intervals were conducted recently in Japan. The Committee on Common Reference Intervals of the Japan Society of Clinical Chemistry sought to establish common reference intervals for 40 laboratory tests which were measured in common in the three studies and regarded as well harmonized in Japan. The study protocols were comparable with recruitment mostly from hospital workers with body mass index ≤28 and no medications. Age and sex distributions were made equal to obtain a final data size of 6345 individuals. Between-subgroup differences were expressed as the SD ratio (between-subgroup SD divided by SD representing the reference interval). Between-study differences were all within acceptable levels, and thus the three datasets were merged. By adopting SD ratio ≥0.50 as a guide, sex-specific reference intervals were necessary for 12 assays. Age-specific reference intervals for females partitioned at age 45 were required for five analytes. The reference intervals derived by the parametric method resulted in appreciable narrowing of the ranges by applying the latent abnormal values exclusion method in 10 items which were closely associated with prevalent disorders among healthy individuals. Sex- and age-related profiles of reference values, derived from individuals with no abnormal results in major tests, showed peculiar patterns specific to each analyte. Common reference intervals for nationwide use were developed for 40 major tests, based on three multicentre studies by advanced statistical methods. Sex- and age-related profiles of reference values are of great relevance not only for interpreting test results, but for applying clinical decision limits specified in various clinical guidelines. © The Author(s) 2015.

  14. Reference-free ground truth metric for metal artifact evaluation in CT images.

    PubMed

    Kratz, Bärbel; Ens, Svitlana; Müller, Jan; Buzug, Thorsten M

    2011-07-01

    In computed tomography (CT), metal objects in the region of interest introduce data inconsistencies during acquisition. Reconstructing these data results in an image with star shaped artifacts induced by the metal inconsistencies. To enhance image quality, the influence of the metal objects can be reduced by different metal artifact reduction (MAR) strategies. For an adequate evaluation of new MAR approaches a ground truth reference data set is needed. In technical evaluations, where phantoms can be measured with and without metal inserts, ground truth data can easily be obtained by a second reference data acquisition. Obviously, this is not possible for clinical data. Here, an alternative evaluation method is presented without the need of an additionally acquired reference data set. The proposed metric is based on an inherent ground truth for metal artifacts as well as MAR methods comparison, where no reference information in terms of a second acquisition is needed. The method is based on the forward projection of a reconstructed image, which is compared to the actually measured projection data. The new evaluation technique is performed on phantom and on clinical CT data with and without MAR. The metric results are then compared with methods using a reference data set as well as an expert-based classification. It is shown that the new approach is an adequate quantification technique for artifact strength in reconstructed metal or MAR CT images. The presented method works solely on the original projection data itself, which yields some advantages compared to distance measures in image domain using two data sets. Beside this, no parameters have to be manually chosen. The new metric is a useful evaluation alternative when no reference data are available.

  15. 9 CFR 77.1 - Material incorporated by reference.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... AGRICULTURE INTERSTATE TRANSPORTATION OF ANIMALS (INCLUDING POULTRY) AND ANIMAL PRODUCTS TUBERCULOSIS General Provisions § 77.1 Material incorporated by reference. Uniform Methods and Rules—Bovine Tuberculosis Eradication. The Uniform Methods and Rules—Bovine Tuberculosis Eradication (January 22, 1999, edition) has...

  16. 9 CFR 77.1 - Material incorporated by reference.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... AGRICULTURE INTERSTATE TRANSPORTATION OF ANIMALS (INCLUDING POULTRY) AND ANIMAL PRODUCTS TUBERCULOSIS General Provisions § 77.1 Material incorporated by reference. Uniform Methods and Rules—Bovine Tuberculosis Eradication. The Uniform Methods and Rules—Bovine Tuberculosis Eradication (January 22, 1999, edition) has...

  17. 9 CFR 77.1 - Material incorporated by reference.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... AGRICULTURE INTERSTATE TRANSPORTATION OF ANIMALS (INCLUDING POULTRY) AND ANIMAL PRODUCTS TUBERCULOSIS General Provisions § 77.1 Material incorporated by reference. Uniform Methods and Rules—Bovine Tuberculosis Eradication. The Uniform Methods and Rules—Bovine Tuberculosis Eradication (January 22, 1999, edition) has...

  18. 9 CFR 77.1 - Material incorporated by reference.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... AGRICULTURE INTERSTATE TRANSPORTATION OF ANIMALS (INCLUDING POULTRY) AND ANIMAL PRODUCTS TUBERCULOSIS General Provisions § 77.1 Material incorporated by reference. Uniform Methods and Rules—Bovine Tuberculosis Eradication. The Uniform Methods and Rules—Bovine Tuberculosis Eradication (January 22, 1999, edition) has...

  19. 9 CFR 77.1 - Material incorporated by reference.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... AGRICULTURE INTERSTATE TRANSPORTATION OF ANIMALS (INCLUDING POULTRY) AND ANIMAL PRODUCTS TUBERCULOSIS General Provisions § 77.1 Material incorporated by reference. Uniform Methods and Rules—Bovine Tuberculosis Eradication. The Uniform Methods and Rules—Bovine Tuberculosis Eradication (January 22, 1999, edition) has...

  20. Quantitative estimation of α-PVP metabolites in urine by GC-APCI-QTOFMS with nitrogen chemiluminescence detection based on parent drug calibration.

    PubMed

    Mesihää, Samuel; Rasanen, Ilpo; Ojanperä, Ilkka

    2018-05-01

    Gas chromatography (GC) hyphenated with nitrogen chemiluminescence detection (NCD) and quadrupole time-of-flight mass spectrometry (QTOFMS) was applied for the first time to the quantitative analysis of new psychoactive substances (NPS) in urine, based on the N-equimolar response of NCD. A method was developed and validated to estimate the concentrations of three metabolites of the common stimulant NPS α-pyrrolidinovalerophenone (α-PVP) in spiked urine samples, simulating an analysis having no authentic reference standards for the metabolites and using the parent drug instead for quantitative calibration. The metabolites studied were OH-α-PVP (M1), 2″-oxo-α-PVP (M3), and N,N-bis-dealkyl-PVP (2-amino-1-phenylpentan-1-one; M5). Sample preparation involved liquid-liquid extraction with a mixture of ethyl acetate and butyl chloride at a basic pH and subsequent silylation of the sec-hydroxyl and prim-amino groups of M1 and M5, respectively. Simultaneous compound identification was based on the accurate masses of the protonated molecules for each compound by QTOFMS following atmospheric pressure chemical ionization. The accuracy of quantification of the parent-calibrated NCD method was compared with that of the corresponding parent-calibrated QTOFMS method, as well as with a reference QTOFMS method calibrated with the authentic reference standards. The NCD method produced an equally good accuracy to the reference method for α-PVP, M3 and M5, while a higher negative bias (25%) was obtained for M1, best explainable by recovery and stability issues. The performance of the parent-calibrated QTOFMS method was inferior to the reference method with an especially high negative bias (60%) for M1. The NCD method enabled better quantitative precision than the QTOFMS methods To evaluate the novel approach in casework, twenty post- mortem urine samples previously found positive for α-PVP were analyzed by the parent calibrated NCD method and the reference QTOFMS method. The highest difference in the quantitative results between the two methods was only 33%, and the NCD method's precision as the coefficient of variation was better than 13%. The limit of quantification for the NCD method was approximately 0.25μg/mL in urine, which generally allowed the analysis of α-PVP and the main metabolite M1. However, the sensitivity was not sufficient for the low concentrations of M3 and M5. Consequently, while having potential for instant analysis of NPS and metabolites in moderate concentrations without reference standards, the NCD method should be further developed for improved sensitivity to be more generally applicable. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Fast first arrival picking algorithm for noisy microseismic data

    NASA Astrophysics Data System (ADS)

    Kim, Dowan; Byun, Joongmoo; Lee, Minho; Choi, Jihoon; Kim, Myungsun

    2017-01-01

    Most microseismic events occur during hydraulic fracturing. Thus microseismic monitoring, by recording seismic waves from microseismic events, is one of the best methods for locating the positions of hydraulic fractures. However, since microseismic events have very low energy, the data often have a low signal-to-noise ratio (S/N ratio) and it is not easy to pick the first arrival time. In this study, we suggest a new fast picking method optimised for noisy data using cross-correlation and stacking. In this method, a reference trace is selected and the time differences between the first arrivals of the reference trace and those of the other traces are computed by cross-correlation. Then, all traces are aligned with the reference trace by time shifting, and the aligned traces are summed together to produce a stacked reference trace that has a considerably improved S/N ratio. After the first arrival time of the stacked reference trace is picked, the first arrival time of each trace is calculated automatically using the time differences obtained in the cross-correlation process. In experiments with noisy synthetic data and field data, this method produces more reliable results than the traditional method, which picks the first arrival time of each noisy trace separately. In addition, the computation time is dramatically reduced.

  2. The Librarian as Information Consultant: Transforming Reference for the Information Age

    ERIC Educational Resources Information Center

    Murphy, Sarah Anne

    2011-01-01

    Library users' evolving information needs and their choice of search methods have changed reference work profoundly. Today's reference librarian must work in a whole new way--not only service-focused and businesslike, but even entrepreneurial. Murphy innovatively rethinks the philosophy behind current library reference services in this…

  3. Implementation and Use of the Reference Analytics Module of LibAnswers

    ERIC Educational Resources Information Center

    Flatley, Robert; Jensen, Robert Bruce

    2012-01-01

    Academic libraries have traditionally collected reference statistics using hash marks on paper. Although efficient and simple, this method is not an effective way to capture the complexity of reference transactions. Several electronic tools are now available to assist libraries with collecting often elusive reference data--among them homegrown…

  4. 40 CFR Table A-1 to Subpart A of... - Summary of Applicable Requirements for Reference and Equivalent Methods for Air Monitoring of...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Methods for Air Monitoring of Criteria Pollutants Pollutant Ref. or equivalent Manual or automated Applicable part 50 appendix Applicable subparts of part 53 A B C D E F SO2 Reference Manual A Equivalent Manual ✓ ✓ Automated ✓ ✓ ✓ CO Reference Automated C ✓ ✓ Equivalent Manual ✓ ✓ Automated ✓ ✓ ✓ O3...

  5. Carrier-frequency synchronization system for improved amplitude modulation and television broadcast reception

    DOEpatents

    Smith, Stephen F.; Moore, James A.

    2003-05-13

    Systems and methods are described for carrier-frequency synchronization for improved AM and TV broadcast reception. A method includes synchronizing a carrier frequency of a broadcast signal with a remote reference frequency. An apparatus includes a reference signal receiver; a phase comparator coupled to the reference signal receiver; a voltage controlled oscillator coupled to the phase comparator; and a radio frequency output coupled to the voltage controlled oscillator.

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, Stephen F; Moore, James A

    Systems and methods are described for carrier phase synchronization for improved AM and TV broadcast reception. A method includes synchronizing the phase of a carrier frequency of a broadcast signal with the phase of a remote reference frequency. An apparatus includes a receiver to detect the phase of a reference signal; a phase comparator coupled to the reference signal-phase receiver; a voltage controlled oscillator coupled to the phase comparator; and a phase-controlled radio frequency output coupled to the voltage controlled oscillator.

  7. Which method should be the reference method to evaluate the severity of rheumatic mitral stenosis? Gorlin's method versus 3D-echo.

    PubMed

    Pérez de Isla, Leopoldo; Casanova, Carlos; Almería, Carlos; Rodrigo, José Luis; Cordeiro, Pedro; Mataix, Luis; Aubele, Ada Lia; Lang, Roberto; Zamorano, José Luis

    2007-12-01

    Several studies have shown a wide variability among different methods to determine the valve area in patients with rheumatic mitral stenosis. Our aim was to evaluate if 3D-echo planimetry is more accurate than the Gorlin method to measure the valve area. Twenty-six patients with mitral stenosis underwent 2D and 3D-echo echocardiographic examinations and catheterization. Valve area was estimated by different methods. A median value of the mitral valve area, obtained from the measurements of three classical non-invasive methods (2D planimetry, pressure half-time and PISA method), was used as the reference method and it was compared with 3D-echo planimetry and Gorlin's method. Our results showed that the accuracy of 3D-echo planimetry is superior to the accuracy of the Gorlin method for the assessment of mitral valve area. We should keep in mind the fact that 3D-echo planimetry may be a better reference method than the Gorlin method to assess the severity of rheumatic mitral stenosis.

  8. Automatic identification of the reference system based on the fourth ventricular landmarks in T1-weighted MR images.

    PubMed

    Fu, Yili; Gao, Wenpeng; Chen, Xiaoguang; Zhu, Minwei; Shen, Weigao; Wang, Shuguo

    2010-01-01

    The reference system based on the fourth ventricular landmarks (including the fastigial point and ventricular floor plane) is used in medical image analysis of the brain stem. The objective of this study was to develop a rapid, robust, and accurate method for the automatic identification of this reference system on T1-weighted magnetic resonance images. The fully automated method developed in this study consisted of four stages: preprocessing of the data set, expectation-maximization algorithm-based extraction of the fourth ventricle in the region of interest, a coarse-to-fine strategy for identifying the fastigial point, and localization of the base point. The method was evaluated on 27 Brain Web data sets qualitatively and 18 Internet Brain Segmentation Repository data sets and 30 clinical scans quantitatively. The results of qualitative evaluation indicated that the method was robust to rotation, landmark variation, noise, and inhomogeneity. The results of quantitative evaluation indicated that the method was able to identify the reference system with an accuracy of 0.7 +/- 0.2 mm for the fastigial point and 1.1 +/- 0.3 mm for the base point. It took <6 seconds for the method to identify the related landmarks on a personal computer with an Intel Core 2 6300 processor and 2 GB of random-access memory. The proposed method for the automatic identification of the reference system based on the fourth ventricular landmarks was shown to be rapid, robust, and accurate. The method has potentially utility in image registration and computer-aided surgery.

  9. Runtime Support for Type-Safe Dynamic Java Classes

    DTIC Science & Technology

    2000-01-01

    Section 4.3. For each dynamic class C, we create a proxy class, Cproxy, and an implementation class, Cimp . In order to wrap method calls, Cproxy...wrapper method (W) and a reference to the associated method body (M). W explicitly invokes M, which points to the corresponding method body in Cimp ...When C’s implementation Cimp is switched, M is updated to point to the corresponding method object in the new C imp. Cproxy also contains a reference

  10. Note: Improved calibration of atomic force microscope cantilevers using multiple reference cantilevers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sader, John E., E-mail: jsader@unimelb.edu.au; Friend, James R.

    2015-05-15

    Overall precision of the simplified calibration method in J. E. Sader et al., Rev. Sci. Instrum. 83, 103705 (2012), Sec. III D, is dominated by the spring constant of the reference cantilever. The question arises: How does one take measurements from multiple reference cantilevers, and combine these results, to improve uncertainty of the reference cantilever’s spring constant and hence the overall precision of the method? This question is addressed in this note. Its answer enables manufacturers to specify of a single set of data for the spring constant, resonant frequency, and quality factor, from measurements on multiple reference cantilevers. Withmore » this data set, users can trivially calibrate cantilevers of the same type.« less

  11. Validation of a modification to Performance-Tested Method 070601: Reveal Listeria Test for detection of Listeria spp. in selected foods and selected environmental samples.

    PubMed

    Alles, Susan; Peng, Linda X; Mozola, Mark A

    2009-01-01

    A modification to Performance-Tested Method (PTM) 070601, Reveal Listeria Test (Reveal), is described. The modified method uses a new media formulation, LESS enrichment broth, in single-step enrichment protocols for both foods and environmental sponge and swab samples. Food samples are enriched for 27-30 h at 30 degrees C and environmental samples for 24-48 h at 30 degrees C. Implementation of these abbreviated enrichment procedures allows test results to be obtained on a next-day basis. In testing of 14 food types in internal comparative studies with inoculated samples, there was a statistically significant difference in performance between the Reveal and reference culture [U.S. Food and Drug Administration's Bacteriological Analytical Manual (FDA/BAM) or U.S. Department of Agriculture-Food Safety and Inspection Service (USDA-FSIS)] methods for only a single food in one trial (pasteurized crab meat) at the 27 h enrichment time point, with more positive results obtained with the FDA/BAM reference method. No foods showed statistically significant differences in method performance at the 30 h time point. Independent laboratory testing of 3 foods again produced a statistically significant difference in results for crab meat at the 27 h time point; otherwise results of the Reveal and reference methods were statistically equivalent. Overall, considering both internal and independent laboratory trials, sensitivity of the Reveal method relative to the reference culture procedures in testing of foods was 85.9% at 27 h and 97.1% at 30 h. Results from 5 environmental surfaces inoculated with various strains of Listeria spp. showed that the Reveal method was more productive than the reference USDA-FSIS culture procedure for 3 surfaces (stainless steel, plastic, and cast iron), whereas results were statistically equivalent to the reference method for the other 2 surfaces (ceramic tile and sealed concrete). An independent laboratory trial with ceramic tile inoculated with L. monocytogenes confirmed the effectiveness of the Reveal method at the 24 h time point. Overall, sensitivity of the Reveal method at 24 h relative to that of the USDA-FSIS method was 153%. The Reveal method exhibited extremely high specificity, with only a single false-positive result in all trials combined for overall specificity of 99.5%.

  12. Establishing physico-chemical reference conditions in Mediterranean streams according to the European Water Framework Directive.

    PubMed

    Sánchez-Montoya, María del Mar; Arce, Maria Isabel; Vidal-Abarca, María Rosario; Suárez, María Luisa; Prat, Narcís; Gómez, Rosa

    2012-05-01

    Type-specific physico-chemical reference conditions are required for the assessment of ecological status in the Water Framework Directive context, similarly to the biological and hydro-morphological elements. This directive emphasises that natural variability of quality elements in high status (reference condition) needs to be quantified. Mediterranean streams often present a marked seasonal pattern in hydrological, biological and geochemical processes which could affect physico-chemical reference conditions. This study establishes general physico-chemical reference conditions (oxygenation, nutrient, salinity and acidification conditions) for different Mediterranean stream types. 116 potential reference sites located in 23 Mediterranean catchments in Spain were sampled in spring, summer and autumn in 2003. All sites were subjected to a screening method for the selection of reference sites in Mediterranean streams (Mediterranean Reference Criteria) and classified using a pre-established stream typology that establishes five different stream types (temporary streams, evaporite-calcareous at medium altitude, siliceous headwaters, calcareous headwaters and large watercourses). Reference conditions (reference value and reference threshold equivalents to high-good class boundary) were calculated using two different methods according to the availability of reference sites: the reference site 75th percentile approach of all reference sites and the 25th percentile of the population approach. The majority of the studied potential reference sites (76 out of 116) were selected as reference sites. Regarding type-specific reference conditions, only siliceous headwaters could be considered different from the rest of stream types because lower conductivity and pH. All reference stream types presented seasonal differences as regards some parameters, except for temporary streams due to the high natural variation of this stream type. For those parameters which presented seasonal differences in a specific stream type, the least restrictive values were proposed as reference conditions. Copyright © 2012 Elsevier Ltd. All rights reserved.

  13. Harmonized Reference Ranges for Circulating Testosterone Levels in Men of Four Cohort Studies in the United States and Europe

    PubMed Central

    Travison, Thomas G.; Vesper, Hubert W.; Orwoll, Eric; Wu, Frederick; Kaufman, Jean Marc; Wang, Ying; Lapauw, Bruno; Fiers, Tom; Matsumoto, Alvin M.

    2017-01-01

    Background: Reference ranges for testosterone are essential for making a diagnosis of hypogonadism in men. Objective: To establish harmonized reference ranges for total testosterone in men that can be applied across laboratories by cross-calibrating assays to a reference method and standard. Population: The 9054 community-dwelling men in cohort studies in the United States and Europe: Framingham Heart Study; European Male Aging Study; Osteoporotic Fractures in Men Study; and Male Sibling Study of Osteoporosis. Methods: Testosterone concentrations in 100 participants in each of the four cohorts were measured using a reference method at Centers for Disease Control and Prevention (CDC). Generalized additive models and Bland-Altman analyses supported the use of normalizing equations for transformation between cohort-specific and CDC values. Normalizing equations, generated using Passing-Bablok regression, were used to generate harmonized values, which were used to derive standardized, age-specific reference ranges. Results: Harmonization procedure reduced intercohort variation between testosterone measurements in men of similar ages. In healthy nonobese men, 19 to 39 years, harmonized 2.5th, 5th, 50th, 95th, and 97.5th percentile values were 264, 303, 531, 852, and 916 ng/dL, respectively. Age-specific harmonized testosterone concentrations in nonobese men were similar across cohorts and greater than in all men. Conclusion: Harmonized normal range in a healthy nonobese population of European and American men, 19 to 39 years, is 264 to 916 ng/dL. A substantial proportion of intercohort variation in testosterone levels is due to assay differences. These data demonstrate the feasibility of generating harmonized reference ranges for testosterone that can be applied to assays, which have been calibrated to a reference method and calibrator. PMID:28324103

  14. A method to improve visual similarity of breast masses for an interactive computer-aided diagnosis environment.

    PubMed

    Zheng, Bin; Lu, Amy; Hardesty, Lara A; Sumkin, Jules H; Hakim, Christiane M; Ganott, Marie A; Gur, David

    2006-01-01

    The purpose of this study was to develop and test a method for selecting "visually similar" regions of interest depicting breast masses from a reference library to be used in an interactive computer-aided diagnosis (CAD) environment. A reference library including 1000 malignant mass regions and 2000 benign and CAD-generated false-positive regions was established. When a suspicious mass region is identified, the scheme segments the region and searches for similar regions from the reference library using a multifeature based k-nearest neighbor (KNN) algorithm. To improve selection of reference images, we added an interactive step. All actual masses in the reference library were subjectively rated on a scale from 1 to 9 as to their "visual margins speculations". When an observer identifies a suspected mass region during a case interpretation he/she first rates the margins and the computerized search is then limited only to regions rated as having similar levels of spiculation (within +/-1 scale difference). In an observer preference study including 85 test regions, two sets of the six "similar" reference regions selected by the KNN with and without the interactive step were displayed side by side with each test region. Four radiologists and five nonclinician observers selected the more appropriate ("similar") reference set in a two alternative forced choice preference experiment. All four radiologists and five nonclinician observers preferred the sets of regions selected by the interactive method with an average frequency of 76.8% and 74.6%, respectively. The overall preference for the interactive method was highly significant (p < 0.001). The study demonstrated that a simple interactive approach that includes subjectively perceived ratings of one feature alone namely, a rating of margin "spiculation," could substantially improve the selection of "visually similar" reference images.

  15. Rapid assessment of urban wetlands: Do hydrogeomorpic classification and reference criteria work?

    EPA Science Inventory

    The Hydrogeomorphic (HGM) functional assessment method is predicated on the ability of a wetland classification method based on hydrology (HGM classification) and a visual assessment of disturbance and alteration to provide reference standards against which functions in individua...

  16. Reference layer adaptive filtering (RLAF) for EEG artifact reduction in simultaneous EEG-fMRI.

    PubMed

    Steyrl, David; Krausz, Gunther; Koschutnig, Karl; Edlinger, Günter; Müller-Putz, Gernot R

    2017-04-01

    Simultaneous electroencephalography (EEG) and functional magnetic resonance imaging (fMRI) combines advantages of both methods, namely high temporal resolution of EEG and high spatial resolution of fMRI. However, EEG quality is limited due to severe artifacts caused by fMRI scanners. To improve EEG data quality substantially, we introduce methods that use a reusable reference layer EEG cap prototype in combination with adaptive filtering. The first method, reference layer adaptive filtering (RLAF), uses adaptive filtering with reference layer artifact data to optimize artifact subtraction from EEG. In the second method, multi band reference layer adaptive filtering (MBRLAF), adaptive filtering is performed on bandwidth limited sub-bands of the EEG and the reference channels. The results suggests that RLAF outperforms the baseline method, average artifact subtraction, in all settings and also its direct predecessor, reference layer artifact subtraction (RLAS), in lower (<35 Hz) frequency ranges. MBRLAF is computationally more demanding than RLAF, but highly effective in all EEG frequency ranges. Effectivity is determined by visual inspection, as well as root-mean-square voltage reduction and power reduction of EEG provided that physiological EEG components such as occipital EEG alpha power and visual evoked potentials (VEP) are preserved. We demonstrate that both, RLAF and MBRLAF, improve VEP quality. For that, we calculate the mean-squared-distance of single trial VEP to the mean VEP and estimate single trial VEP classification accuracies. We found that the average mean-squared-distance is lowest and the average classification accuracy is highest after MBLAF. RLAF was second best. In conclusion, the results suggests that RLAF and MBRLAF are potentially very effective in improving EEG quality of simultaneous EEG-fMRI. Highlights We present a new and reusable reference layer cap prototype for simultaneous EEG-fMRI We introduce new algorithms for reducing EEG artifacts due to simultaneous fMRI The algorithms combine a reference layer and adaptive filtering Several evaluation criteria suggest superior effectivity in terms of artifact reduction We demonstrate that physiological EEG components are preserved.

  17. Reference layer adaptive filtering (RLAF) for EEG artifact reduction in simultaneous EEG-fMRI

    NASA Astrophysics Data System (ADS)

    Steyrl, David; Krausz, Gunther; Koschutnig, Karl; Edlinger, Günter; Müller-Putz, Gernot R.

    2017-04-01

    Objective. Simultaneous electroencephalography (EEG) and functional magnetic resonance imaging (fMRI) combines advantages of both methods, namely high temporal resolution of EEG and high spatial resolution of fMRI. However, EEG quality is limited due to severe artifacts caused by fMRI scanners. Approach. To improve EEG data quality substantially, we introduce methods that use a reusable reference layer EEG cap prototype in combination with adaptive filtering. The first method, reference layer adaptive filtering (RLAF), uses adaptive filtering with reference layer artifact data to optimize artifact subtraction from EEG. In the second method, multi band reference layer adaptive filtering (MBRLAF), adaptive filtering is performed on bandwidth limited sub-bands of the EEG and the reference channels. Main results. The results suggests that RLAF outperforms the baseline method, average artifact subtraction, in all settings and also its direct predecessor, reference layer artifact subtraction (RLAS), in lower (<35 Hz) frequency ranges. MBRLAF is computationally more demanding than RLAF, but highly effective in all EEG frequency ranges. Effectivity is determined by visual inspection, as well as root-mean-square voltage reduction and power reduction of EEG provided that physiological EEG components such as occipital EEG alpha power and visual evoked potentials (VEP) are preserved. We demonstrate that both, RLAF and MBRLAF, improve VEP quality. For that, we calculate the mean-squared-distance of single trial VEP to the mean VEP and estimate single trial VEP classification accuracies. We found that the average mean-squared-distance is lowest and the average classification accuracy is highest after MBLAF. RLAF was second best. Significance. In conclusion, the results suggests that RLAF and MBRLAF are potentially very effective in improving EEG quality of simultaneous EEG-fMRI. Highlights We present a new and reusable reference layer cap prototype for simultaneous EEG-fMRI We introduce new algorithms for reducing EEG artifacts due to simultaneous fMRI The algorithms combine a reference layer and adaptive filtering Several evaluation criteria suggest superior effectivity in terms of artifact reduction We demonstrate that physiological EEG components are preserved

  18. A global multicenter study on reference values: 1. Assessment of methods for derivation and comparison of reference intervals.

    PubMed

    Ichihara, Kiyoshi; Ozarda, Yesim; Barth, Julian H; Klee, George; Qiu, Ling; Erasmus, Rajiv; Borai, Anwar; Evgina, Svetlana; Ashavaid, Tester; Khan, Dilshad; Schreier, Laura; Rolle, Reynan; Shimizu, Yoshihisa; Kimura, Shogo; Kawano, Reo; Armbruster, David; Mori, Kazuo; Yadav, Binod K

    2017-04-01

    The IFCC Committee on Reference Intervals and Decision Limits coordinated a global multicenter study on reference values (RVs) to explore rational and harmonizable procedures for derivation of reference intervals (RIs) and investigate the feasibility of sharing RIs through evaluation of sources of variation of RVs on a global scale. For the common protocol, rather lenient criteria for reference individuals were adopted to facilitate harmonized recruitment with planned use of the latent abnormal values exclusion (LAVE) method. As of July 2015, 12 countries had completed their study with total recruitment of 13,386 healthy adults. 25 analytes were measured chemically and 25 immunologically. A serum panel with assigned values was measured by all laboratories. RIs were derived by parametric and nonparametric methods. The effect of LAVE methods is prominent in analytes which reflect nutritional status, inflammation and muscular exertion, indicating that inappropriate results are frequent in any country. The validity of the parametric method was confirmed by the presence of analyte-specific distribution patterns and successful Gaussian transformation using the modified Box-Cox formula in all countries. After successful alignment of RVs based on the panel test results, nearly half the analytes showed variable degrees of between-country differences. This finding, however, requires confirmation after adjusting for BMI and other sources of variation. The results are reported in the second part of this paper. The collaborative study enabled us to evaluate rational methods for deriving RIs and comparing the RVs based on real-world datasets obtained in a harmonized manner. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  19. Accurate determination of reference materials and natural isolates by means of quantitative (1)h NMR spectroscopy.

    PubMed

    Frank, Oliver; Kreissl, Johanna Karoline; Daschner, Andreas; Hofmann, Thomas

    2014-03-26

    A fast and precise proton nuclear magnetic resonance (qHNMR) method for the quantitative determination of low molecular weight target molecules in reference materials and natural isolates has been validated using ERETIC 2 (Electronic REference To access In vivo Concentrations) based on the PULCON (PULse length based CONcentration determination) methodology and compared to the gravimetric results. Using an Avance III NMR spectrometer (400 MHz) equipped with a broad band observe (BBO) probe, the qHNMR method was validated by determining its linearity, range, precision, and accuracy as well as robustness and limit of quantitation. The linearity of the method was assessed by measuring samples of l-tyrosine, caffeine, or benzoic acid in a concentration range between 0.3 and 16.5 mmol/L (r(2) ≥ 0.99), whereas the interday and intraday precisions were found to be ≤2%. The recovery of a range of reference compounds was ≥98.5%, thus demonstrating the qHNMR method as a precise tool for the rapid quantitation (~15 min) of food-related target compounds in reference materials and natural isolates such as nucleotides, polyphenols, or cyclic peptides.

  20. Two new computational methods for universal DNA barcoding: a benchmark using barcode sequences of bacteria, archaea, animals, fungi, and land plants.

    PubMed

    Tanabe, Akifumi S; Toju, Hirokazu

    2013-01-01

    Taxonomic identification of biological specimens based on DNA sequence information (a.k.a. DNA barcoding) is becoming increasingly common in biodiversity science. Although several methods have been proposed, many of them are not universally applicable due to the need for prerequisite phylogenetic/machine-learning analyses, the need for huge computational resources, or the lack of a firm theoretical background. Here, we propose two new computational methods of DNA barcoding and show a benchmark for bacterial/archeal 16S, animal COX1, fungal internal transcribed spacer, and three plant chloroplast (rbcL, matK, and trnH-psbA) barcode loci that can be used to compare the performance of existing and new methods. The benchmark was performed under two alternative situations: query sequences were available in the corresponding reference sequence databases in one, but were not available in the other. In the former situation, the commonly used "1-nearest-neighbor" (1-NN) method, which assigns the taxonomic information of the most similar sequences in a reference database (i.e., BLAST-top-hit reference sequence) to a query, displays the highest rate and highest precision of successful taxonomic identification. However, in the latter situation, the 1-NN method produced extremely high rates of misidentification for all the barcode loci examined. In contrast, one of our new methods, the query-centric auto-k-nearest-neighbor (QCauto) method, consistently produced low rates of misidentification for all the loci examined in both situations. These results indicate that the 1-NN method is most suitable if the reference sequences of all potentially observable species are available in databases; otherwise, the QCauto method returns the most reliable identification results. The benchmark results also indicated that the taxon coverage of reference sequences is far from complete for genus or species level identification in all the barcode loci examined. Therefore, we need to accelerate the registration of reference barcode sequences to apply high-throughput DNA barcoding to genus or species level identification in biodiversity research.

  1. Two New Computational Methods for Universal DNA Barcoding: A Benchmark Using Barcode Sequences of Bacteria, Archaea, Animals, Fungi, and Land Plants

    PubMed Central

    Tanabe, Akifumi S.; Toju, Hirokazu

    2013-01-01

    Taxonomic identification of biological specimens based on DNA sequence information (a.k.a. DNA barcoding) is becoming increasingly common in biodiversity science. Although several methods have been proposed, many of them are not universally applicable due to the need for prerequisite phylogenetic/machine-learning analyses, the need for huge computational resources, or the lack of a firm theoretical background. Here, we propose two new computational methods of DNA barcoding and show a benchmark for bacterial/archeal 16S, animal COX1, fungal internal transcribed spacer, and three plant chloroplast (rbcL, matK, and trnH-psbA) barcode loci that can be used to compare the performance of existing and new methods. The benchmark was performed under two alternative situations: query sequences were available in the corresponding reference sequence databases in one, but were not available in the other. In the former situation, the commonly used “1-nearest-neighbor” (1-NN) method, which assigns the taxonomic information of the most similar sequences in a reference database (i.e., BLAST-top-hit reference sequence) to a query, displays the highest rate and highest precision of successful taxonomic identification. However, in the latter situation, the 1-NN method produced extremely high rates of misidentification for all the barcode loci examined. In contrast, one of our new methods, the query-centric auto-k-nearest-neighbor (QCauto) method, consistently produced low rates of misidentification for all the loci examined in both situations. These results indicate that the 1-NN method is most suitable if the reference sequences of all potentially observable species are available in databases; otherwise, the QCauto method returns the most reliable identification results. The benchmark results also indicated that the taxon coverage of reference sequences is far from complete for genus or species level identification in all the barcode loci examined. Therefore, we need to accelerate the registration of reference barcode sequences to apply high-throughput DNA barcoding to genus or species level identification in biodiversity research. PMID:24204702

  2. Transport equations of electrodiffusion processes in the laboratory reference frame.

    PubMed

    Garrido, Javier

    2006-02-23

    The transport equations of electrodiffusion processes use three reference frames for defining the fluxes: Fick's reference in diffusion, solvent-fixed reference in transference numbers, and laboratory fluxes in electric conductivity. The convenience of using only one reference frame is analyzed here from the point of view of the thermodynamics of irreversible processes. A relation between the fluxes of ions and solvent and the electric current density is deduced first from a mass and volume balance. This is then used to show that (i) the laboratory and Fick's diffusion coefficients are identical and (ii) the transference numbers of both the solvent and the ion in the laboratory reference frame are related. Finally, four experimental methods for the measurement of ion transference numbers are analyzed critically. New expressions for evaluating transference numbers for the moving boundary method and the chronopotentiometry technique are deduced. It is concluded that the ion transport equation in the laboratory reference frame plays a key role in the description of electrodiffusion processes.

  3. Phase modulated high density collinear holographic data storage system with phase-retrieval reference beam locking and orthogonal reference encoding.

    PubMed

    Liu, Jinpeng; Horimai, Hideyoshi; Lin, Xiao; Huang, Yong; Tan, Xiaodi

    2018-02-19

    A novel phase modulation method for holographic data storage with phase-retrieval reference beam locking is proposed and incorporated into an amplitude-encoding collinear holographic storage system. Unlike the conventional phase retrieval method, the proposed method locks the data page and the corresponding phase-retrieval interference beam together at the same location with a sequential recording process, which eliminates piezoelectric elements, phase shift arrays and extra interference beams, making the system more compact and phase retrieval easier. To evaluate our proposed phase modulation method, we recorded and then recovered data pages with multilevel phase modulation using two spatial light modulators experimentally. For 4-level, 8-level, and 16-level phase modulation, we achieved the bit error rate (BER) of 0.3%, 1.5% and 6.6% respectively. To further improve data storage density, an orthogonal reference encoding multiplexing method at the same position of medium is also proposed and validated experimentally. We increased the code rate of pure 3/16 amplitude encoding method from 0.5 up to 1.0 and 1.5 using 4-level and 8-level phase modulation respectively.

  4. Dual-domain point diffraction interferometer

    DOEpatents

    Naulleau, Patrick P.; Goldberg, Kenneth Alan

    2000-01-01

    A hybrid spatial/temporal-domain point diffraction interferometer (referred to as the dual-domain PS/PDI) that is capable of suppressing the scattered-reference-light noise that hinders the conventional PS/PDI is provided. The dual-domain PS/PDI combines the separate noise-suppression capabilities of the widely-used phase-shifting and Fourier-transform fringe pattern analysis methods. The dual-domain PS/PDI relies on both a more restrictive implementation of the image plane PS/PDI mask and a new analysis method to be applied to the interferograms generated and recorded by the modified PS/PDI. The more restrictive PS/PDI mask guarantees the elimination of spatial-frequency crosstalk between the signal and the scattered-light noise arising from scattered-reference-light interfering with the test beam. The new dual-domain analysis method is then used to eliminate scattered-light noise arising from both the scattered-reference-light interfering with the test beam and the scattered-reference-light interfering with the "true" pinhole-diffracted reference light. The dual-domain analysis method has also been demonstrated to provide performance enhancement when using the non-optimized standard PS/PDI design. The dual-domain PS/PDI is essentially a three-tiered filtering system composed of lowpass spatial-filtering the test-beam electric field using the more restrictive PS/PDI mask, bandpass spatial-filtering the individual interferogram irradiance frames making up the phase-shifting series, and bandpass temporal-filtering the phase-shifting series as a whole.

  5. Comparison of Haemophilus parasuis reference strains and field isolates by using random amplified polymorphic DNA and protein profiles

    PubMed Central

    2012-01-01

    Background Haemophilus parasuis is the causative agent of Glässer’s disease and is a pathogen of swine in high-health status herds. Reports on serotyping of field strains from outbreaks describe that approximately 30% of them are nontypeable and therefore cannot be traced. Molecular typing methods have been used as alternatives to serotyping. This study was done to compare random amplified polymorphic DNA (RAPD) profiles and whole cell protein (WCP) lysate profiles as methods for distinguishing H. parasuis reference strains and field isolates. Results The DNA and WCP lysate profiles of 15 reference strains and 31 field isolates of H. parasuis were analyzed using the Dice and neighbor joining algorithms. The results revealed unique and reproducible DNA and protein profiles among the reference strains and field isolates studied. Simpson’s index of diversity showed significant discrimination between isolates when three 10mer primers were combined for the RAPD method and also when both the RAPD and WCP lysate typing methods were combined. Conclusions The RAPD profiles seen among the reference strains and field isolates did not appear to change over time which may reflect a lack of DNA mutations in the genes of the samples. The recent field isolates had different WCP lysate profiles than the reference strains, possibly because the number of passages of the type strains may affect their protein expression. PMID:22703293

  6. Comparison of high-pressure liquid chromatography and microbiological assay for determination of ciprofloxacin tablets in human plasma employed in bioequivalence and pharmacokinetics study.

    PubMed

    Khan, Muhammad Khalid; Khan, Muhammad Farid; Mustafa, Ghulam; Sualah, Mohammed

    2012-01-01

    Ciprofloxacin was given orally to 28 healthy male volunteers for single oral dose of 500mg; Plasma samples were collected at different time's interval between 0 and 12h and analyzed both by high pressure liquid chromatography and by a microbiological assay. The detection limits (LOD) were 0.02μg/ml and 0.1μg/ml, for both methods respectively. For each method, coefficients of variation (R(2)) were 0.9995 and 0.9918 in plasma and limit of quantitation (LOQ).02 and 0.5μg/ml. The Comparison of means maximum concentration 2.68 μg/ml at 1.5 hr for test and 2.43 μg/ml are attain in HPLC method of Reference at 2hrs respectively. The plasma concentrations measured by microbiological assay of reference tablet are 3.95μg/ml (mean ± SE) at 1 hour and 3.80μg/ml (mean ± SE) at 1 hour. The concentrations in plasma measured by microbiological method were markedly higher than the high-pressure liquid chromatography values which indicates the presence of antimicrobially active metabolites. The mean ± SE values of pharmacokinetic parameters calculated by HPLC method, for total area under the curve (AUC 0-oo) were 13.11, and 11.91 h.mg/l for both test and reference tablets respectively. The mean ± SE values of clearance measured in l/h were 44.91 and 48.42 respectively. The elimination rate constant Kel [l/h] showed 0.17 l/h for test and 0.15 l/h reference tablets and likewise, absorption half-life expressed in hours shown 0.67 h for test and 1.04 h for reference respectively. The Mean Residence Time for test is 5.48 h and 5.49 h for reference. The mean ± SE values of pharmacokinetic parameters (Microbiological assay) for total area under the curve (AUC 0-oo) were 22.11 and 19.33 h.mg/l for both test and reference tablets respectively. The mean ± SE values of clearance measured in l/h were 29.02 and 31.63 respectively. The elimination rate constant Kel [l/h] showed 0.21 l/h for test and 0.20 l/h reference tablets and likewise, absorption half-life expressed in hours shown 0.86h for test and 0.56 h for reference respectively. The Mean Residence Time for test is 5.27 h and 4.67 h for reference. Significant difference observed between two methods.

  7. Method and apparatus for rate integration supplement for attitude referencing with quaternion differencing

    NASA Technical Reports Server (NTRS)

    Rodden, John James (Inventor); Price, Xenophon (Inventor); Carrou, Stephane (Inventor); Stevens, Homer Darling (Inventor)

    2002-01-01

    A control system for providing attitude control in spacecraft. The control system comprising a primary attitude reference system, a secondary attitude reference system, and a hyper-complex number differencing system. The hyper-complex number differencing system is connectable to the primary attitude reference system and the secondary attitude reference system.

  8. [Standard sample preparation method for quick determination of trace elements in plastic].

    PubMed

    Yao, Wen-Qing; Zong, Rui-Long; Zhu, Yong-Fa

    2011-08-01

    Reference sample was prepared by masterbatch method, containing heavy metals with known concentration of electronic information products (plastic), the repeatability and precision were determined, and reference sample preparation procedures were established. X-Ray fluorescence spectroscopy (XRF) analysis method was used to determine the repeatability and uncertainty in the analysis of the sample of heavy metals and bromine element. The working curve and the metrical methods for the reference sample were carried out. The results showed that the use of the method in the 200-2000 mg x kg(-1) concentration range for Hg, Pb, Cr and Br elements, and in the 20-200 mg x kg(-1) range for Cd elements, exhibited a very good linear relationship, and the repeatability of analysis methods for six times is good. In testing the circuit board ICB288G and ICB288 from the Mitsubishi Heavy Industry Company, results agreed with the recommended values.

  9. Model Reduction via Principe Component Analysis and Markov Chain Monte Carlo (MCMC) Methods

    NASA Astrophysics Data System (ADS)

    Gong, R.; Chen, J.; Hoversten, M. G.; Luo, J.

    2011-12-01

    Geophysical and hydrogeological inverse problems often include a large number of unknown parameters, ranging from hundreds to millions, depending on parameterization and problems undertaking. This makes inverse estimation and uncertainty quantification very challenging, especially for those problems in two- or three-dimensional spatial domains. Model reduction technique has the potential of mitigating the curse of dimensionality by reducing total numbers of unknowns while describing the complex subsurface systems adequately. In this study, we explore the use of principal component analysis (PCA) and Markov chain Monte Carlo (MCMC) sampling methods for model reduction through the use of synthetic datasets. We compare the performances of three different but closely related model reduction approaches: (1) PCA methods with geometric sampling (referred to as 'Method 1'), (2) PCA methods with MCMC sampling (referred to as 'Method 2'), and (3) PCA methods with MCMC sampling and inclusion of random effects (referred to as 'Method 3'). We consider a simple convolution model with five unknown parameters as our goal is to understand and visualize the advantages and disadvantages of each method by comparing their inversion results with the corresponding analytical solutions. We generated synthetic data with noise added and invert them under two different situations: (1) the noised data and the covariance matrix for PCA analysis are consistent (referred to as the unbiased case), and (2) the noise data and the covariance matrix are inconsistent (referred to as biased case). In the unbiased case, comparison between the analytical solutions and the inversion results show that all three methods provide good estimates of the true values and Method 1 is computationally more efficient. In terms of uncertainty quantification, Method 1 performs poorly because of relatively small number of samples obtained, Method 2 performs best, and Method 3 overestimates uncertainty due to inclusion of random effects. However, in the biased case, only Method 3 correctly estimates all the unknown parameters, and both Methods 1 and 2 provide wrong values for the biased parameters. The synthetic case study demonstrates that if the covariance matrix for PCA analysis is inconsistent with true models, the PCA methods with geometric or MCMC sampling will provide incorrect estimates.

  10. 40 CFR 60.396 - Reference methods and procedures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Reference methods and procedures. 60.396 Section 60.396 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Automobile and...

  11. 40 CFR 60.396 - Reference methods and procedures.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Reference methods and procedures. 60.396 Section 60.396 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Automobile and...

  12. 40 CFR 60.396 - Reference methods and procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Reference methods and procedures. 60.396 Section 60.396 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Automobile and...

  13. 40 CFR 53.58 - Operational field precision and blank test.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... PROGRAMS (CONTINUED) AMBIENT AIR MONITORING REFERENCE AND EQUIVALENT METHODS Procedures for Testing Physical (Design) and Performance Characteristics of Reference Methods and Class I and Class II Equivalent... samplers are also subject to a test for possible deposition of particulate matter on inactive filters...

  14. 40 CFR 53.58 - Operational field precision and blank test.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... PROGRAMS (CONTINUED) AMBIENT AIR MONITORING REFERENCE AND EQUIVALENT METHODS Procedures for Testing Physical (Design) and Performance Characteristics of Reference Methods and Class I and Class II Equivalent... samplers are also subject to a test for possible deposition of particulate matter on inactive filters...

  15. 40 CFR 53.58 - Operational field precision and blank test.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... PROGRAMS (CONTINUED) AMBIENT AIR MONITORING REFERENCE AND EQUIVALENT METHODS Procedures for Testing Physical (Design) and Performance Characteristics of Reference Methods and Class I and Class II Equivalent... samplers are also subject to a test for possible deposition of particulate matter on inactive filters...

  16. 40 CFR 53.58 - Operational field precision and blank test.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... PROGRAMS (CONTINUED) AMBIENT AIR MONITORING REFERENCE AND EQUIVALENT METHODS Procedures for Testing Physical (Design) and Performance Characteristics of Reference Methods and Class I and Class II Equivalent... samplers are also subject to a test for possible deposition of particulate matter on inactive filters...

  17. 40 CFR 60.185 - Monitoring of operations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) The continuous monitoring system performance evaluation required under § 60.13(c) shall be completed... monitoring system performance evaluation required under § 60.13(c), the reference method referred to under... be Method 6. For the performance evaluation, each concentration measurement shall be of one hour...

  18. Reconstruction method for fringe projection profilometry based on light beams.

    PubMed

    Li, Xuexing; Zhang, Zhijiang; Yang, Chen

    2016-12-01

    A novel reconstruction method for fringe projection profilometry, based on light beams, is proposed and verified by experiments. Commonly used calibration techniques require the parameters of projector calibration or the reference planes placed in many known positions. Obviously, introducing the projector calibration can reduce the accuracy of the reconstruction result, and setting the reference planes to many known positions is a time-consuming process. Therefore, in this paper, a reconstruction method without projector's parameters is proposed and only two reference planes are introduced. A series of light beams determined by the subpixel point-to-point map on the two reference planes combined with their reflected light beams determined by the camera model are used to calculate the 3D coordinates of reconstruction points. Furthermore, the bundle adjustment strategy and the complementary gray-code phase-shifting method are utilized to ensure the accuracy and stability. Qualitative and quantitative comparisons as well as experimental tests demonstrate the performance of our proposed approach, and the measurement accuracy can reach about 0.0454 mm.

  19. Food adulteration analysis without laboratory prepared or determined reference food adulterant values.

    PubMed

    Kalivas, John H; Georgiou, Constantinos A; Moira, Marianna; Tsafaras, Ilias; Petrakis, Eleftherios A; Mousdis, George A

    2014-04-01

    Quantitative analysis of food adulterants is an important health and economic issue that needs to be fast and simple. Spectroscopy has significantly reduced analysis time. However, still needed are preparations of analyte calibration samples matrix matched to prediction samples which can be laborious and costly. Reported in this paper is the application of a newly developed pure component Tikhonov regularization (PCTR) process that does not require laboratory prepared or reference analysis methods, and hence, is a greener calibration method. The PCTR method requires an analyte pure component spectrum and non-analyte spectra. As a food analysis example, synchronous fluorescence spectra of extra virgin olive oil samples adulterated with sunflower oil is used. Results are shown to be better than those obtained using ridge regression with reference calibration samples. The flexibility of PCTR allows including reference samples and is generic for use with other instrumental methods and food products. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Automated processing for proton spectroscopic imaging using water reference deconvolution.

    PubMed

    Maudsley, A A; Wu, Z; Meyerhoff, D J; Weiner, M W

    1994-06-01

    Automated formation of MR spectroscopic images (MRSI) is necessary before routine application of these methods is possible for in vivo studies; however, this task is complicated by the presence of spatially dependent instrumental distortions and the complex nature of the MR spectrum. A data processing method is presented for completely automated formation of in vivo proton spectroscopic images, and applied for analysis of human brain metabolites. This procedure uses the water reference deconvolution method (G. A. Morris, J. Magn. Reson. 80, 547(1988)) to correct for line shape distortions caused by instrumental and sample characteristics, followed by parametric spectral analysis. Results for automated image formation were found to compare favorably with operator dependent spectral integration methods. While the water reference deconvolution processing was found to provide good correction of spatially dependent resonance frequency shifts, it was found to be susceptible to errors for correction of line shape distortions. These occur due to differences between the water reference and the metabolite distributions.

  1. A method for determining the conversion efficiency of multiple-cell photovoltaic devices

    NASA Astrophysics Data System (ADS)

    Glatfelter, Troy; Burdick, Joseph

    A method for accurately determining the conversion efficiency of any multiple-cell photovoltaic device under any arbitrary reference spectrum is presented. This method makes it possible to obtain not only the short-circuit current, but also the fill factor, the open-circuit voltage, and hence the conversion efficiency of a multiple-cell device under any reference spectrum. Results are presented which allow a comparison of the I-V parameters of two-terminal, two- and three-cell tandem devices measured under a multiple-source simulator with the same parameters measured under different reference spectra. It is determined that the uncertainty in the conversion efficiency of a multiple-cell photovoltaic device obtained with this method is less than +/-3 percent.

  2. Certification of elements in and use of standard reference material 3280 multivitamin/multielement tablets.

    PubMed

    Turk, Gregory C; Sharpless, Katherine E; Cleveland, Danielle; Jongsma, Candice; Mackey, Elizabeth A; Marlow, Anthony F; Oflaz, Rabia; Paul, Rick L; Sieber, John R; Thompson, Robert Q; Wood, Laura J; Yu, Lee L; Zeisler, Rolf; Wise, Stephen A; Yen, James H; Christopher, Steven J; Day, Russell D; Long, Stephen E; Greene, Ella; Harnly, James; Ho, I-Pin; Betz, Joseph M

    2013-01-01

    Standard Reference Material 3280 Multivitamin/ Multielement Tablets was issued by the National Institute of Standards and Technology in 2009, and has certified and reference mass fraction values for 13 vitamins, 26 elements, and two carotenoids. Elements were measured using two or more analytical methods at NIST with additional data contributed by collaborating laboratories. This reference material is expected to serve a dual purpose: to provide quality assurance in support of a database of dietary supplement products and to provide a means for analysts, dietary supplement manufacturers, and researchers to assess the appropriateness and validity of their analytical methods and the accuracy of their results.

  3. 'Aussie normals': an a priori study to develop clinical chemistry reference intervals in a healthy Australian population.

    PubMed

    Koerbin, G; Cavanaugh, J A; Potter, J M; Abhayaratna, W P; West, N P; Glasgow, N; Hawkins, C; Armbruster, D; Oakman, C; Hickman, P E

    2015-02-01

    Development of reference intervals is difficult, time consuming, expensive and beyond the scope of most laboratories. The Aussie Normals study is a direct a priori study to determine reference intervals in healthy Australian adults. All volunteers completed a health and lifestyle questionnaire and exclusion was based on conditions such as pregnancy, diabetes, renal or cardiovascular disease. Up to 91 biochemical analyses were undertaken on a variety of analytical platforms using serum samples collected from 1856 volunteers. We report on our findings for 40 of these analytes and two calculated parameters performed on the Abbott ARCHITECTci8200/ci16200 analysers. Not all samples were analysed for all assays due to volume requirements or assay/instrument availability. Results with elevated interference indices and those deemed unsuitable after clinical evaluation were removed from the database. Reference intervals were partitioned based on the method of Harris and Boyd into three scenarios, combined gender, males and females and age and gender. We have performed a detailed reference interval study on a healthy Australian population considering the effects of sex, age and body mass. These reference intervals may be adapted to other manufacturer's analytical methods using method transference.

  4. Spectral and cross-spectral analysis of uneven time series with the smoothed Lomb-Scargle periodogram and Monte Carlo evaluation of statistical significance

    NASA Astrophysics Data System (ADS)

    Pardo-Igúzquiza, Eulogio; Rodríguez-Tovar, Francisco J.

    2012-12-01

    Many spectral analysis techniques have been designed assuming sequences taken with a constant sampling interval. However, there are empirical time series in the geosciences (sediment cores, fossil abundance data, isotope analysis, …) that do not follow regular sampling because of missing data, gapped data, random sampling or incomplete sequences, among other reasons. In general, interpolating an uneven series in order to obtain a succession with a constant sampling interval alters the spectral content of the series. In such cases it is preferable to follow an approach that works with the uneven data directly, avoiding the need for an explicit interpolation step. The Lomb-Scargle periodogram is a popular choice in such circumstances, as there are programs available in the public domain for its computation. One new computer program for spectral analysis improves the standard Lomb-Scargle periodogram approach in two ways: (1) It explicitly adjusts the statistical significance to any bias introduced by variance reduction smoothing, and (2) it uses a permutation test to evaluate confidence levels, which is better suited than parametric methods when neighbouring frequencies are highly correlated. Another novel program for cross-spectral analysis offers the advantage of estimating the Lomb-Scargle cross-periodogram of two uneven time series defined on the same interval, and it evaluates the confidence levels of the estimated cross-spectra by a non-parametric computer intensive permutation test. Thus, the cross-spectrum, the squared coherence spectrum, the phase spectrum, and the Monte Carlo statistical significance of the cross-spectrum and the squared-coherence spectrum can be obtained. Both of the programs are written in ANSI Fortran 77, in view of its simplicity and compatibility. The program code is of public domain, provided on the website of the journal (http://www.iamg.org/index.php/publisher/articleview/frmArticleID/112/). Different examples (with simulated and real data) are described in this paper to corroborate the methodology and the implementation of these two new programs.

  5. Modification of the BAX Salmonella test kit to include a hot start functionality (modification of AOAC Official Method 2003.09).

    PubMed

    Wallace, F Morgan; DiCosimo, Deana; Farnum, Andrew; Tice, George; Andaloro, Bridget; Davis, Eugene; Burns, Frank R

    2011-01-01

    In 2010, the BAX System PCR assay for Salmonella was modified to include a hot start functionality designed to keep the reaction enzyme inactive until PCR begins. To validate the assay's Official Methods of Analysis status to include this procedure modification, an evaluation was conducted on four food types that were simultaneously analyzed with the BAX System and either the U.S. Food and Drug Administration's Bacteriological Analytical Manual or the U.S. Department of Agriculture-Food Safety and Inspection Service Microbiology Laboratory Guidebook reference method for detecting Salmonella. Identical performance between the BAX System method and the reference methods was observed. Additionally, lysates were analyzed using both the BAX System Classic and BAX System Q7 instruments with identical results using both platforms for all samples tested. Of the 100 samples analyzed, 34 samples were positive for both the BAX System and reference methods, and 66 samples were negative by both the BAX System and reference methods, demonstrating 100% correlation. No instrument platform variation was observed. Additional inclusivity and exclusivity testing using the modified test kit demonstrated the test kit to be 100% accurate in evaluation of test panels of 352 Salmonella strains and 46 non-Salmonella strains.

  6. An aggregate method to calibrate the reference point of cumulative prospect theory-based route choice model for urban transit network

    NASA Astrophysics Data System (ADS)

    Zhang, Yufeng; Long, Man; Luo, Sida; Bao, Yu; Shen, Hanxia

    2015-12-01

    Transit route choice model is the key technology of public transit systems planning and management. Traditional route choice models are mostly based on expected utility theory which has an evident shortcoming that it cannot accurately portray travelers' subjective route choice behavior for their risk preferences are not taken into consideration. Cumulative prospect theory (CPT), a brand new theory, can be used to describe travelers' decision-making process under the condition of uncertainty of transit supply and risk preferences of multi-type travelers. The method to calibrate the reference point, a key parameter to CPT-based transit route choice model, determines the precision of the model to a great extent. In this paper, a new method is put forward to obtain the value of reference point which combines theoretical calculation and field investigation results. Comparing the proposed method with traditional method, it shows that the new method can promote the quality of CPT-based model by improving the accuracy in simulating travelers' route choice behaviors based on transit trip investigation from Nanjing City, China. The proposed method is of great significance to logical transit planning and management, and to some extent makes up the defect that obtaining the reference point is solely based on qualitative analysis.

  7. Optically transmitted and inductively coupled electric reference to access in vivo concentrations for quantitative proton-decoupled ¹³C magnetic resonance spectroscopy.

    PubMed

    Chen, Xing; Pavan, Matteo; Heinzer-Schweizer, Susanne; Boesiger, Peter; Henning, Anke

    2012-01-01

    This report describes our efforts on quantification of tissue metabolite concentrations in mM by nuclear Overhauser enhanced and proton decoupled (13) C magnetic resonance spectroscopy and the Electric Reference To access In vivo Concentrations (ERETIC) method. Previous work showed that a calibrated synthetic magnetic resonance spectroscopy-like signal transmitted through an optical fiber and inductively coupled into a transmit/receive coil represents a reliable reference standard for in vivo (1) H magnetic resonance spectroscopy quantification on a clinical platform. In this work, we introduce a related implementation that enables simultaneous proton decoupling and ERETIC-based metabolite quantification and hence extends the applicability of the ERETIC method to nuclear Overhauser enhanced and proton decoupled in vivo (13) C magnetic resonance spectroscopy. In addition, ERETIC signal stability under the influence of simultaneous proton decoupling is investigated. The proposed quantification method was cross-validated against internal and external reference standards on human skeletal muscle. The ERETIC signal intensity stability was 100.65 ± 4.18% over 3 months including measurements with and without proton decoupling. Glycogen and unsaturated fatty acid concentrations measured with the ERETIC method were in excellent agreement with internal creatine and external phantom reference methods, showing a difference of 1.85 ± 1.21% for glycogen and 1.84 ± 1.00% for unsaturated fatty acid between ERETIC and creatine-based quantification, whereas the deviations between external reference and creatine-based quantification are 6.95 ± 9.52% and 3.19 ± 2.60%, respectively. Copyright © 2011 Wiley Periodicals, Inc.

  8. Ice-Accretion Scaling Using Water-Film Thickness Parameters

    NASA Technical Reports Server (NTRS)

    Anderson, David N.; Feo, Alejandro

    2003-01-01

    Studies were performed at INTA in Spain to determine water-film thickness on a stagnation-point probe inserted in a simulated cloud. The measurements were correlated with non-dimensional parameters describing the flow and the cloud conditions. Icing scaling tests in the NASA Glenn Icing Research Tunnel were then conducted using the Ruff scaling method with the scale velocity found by matching scale and reference values of either the INTA non-dimensional water-film thickness or a Weber number based on that film thickness. For comparison, tests were also performed using the constant drop-size Weber number and the average-velocity methods. The reference and scale models were both aluminum, 61-cm-span, NACA 0012 airfoil sections at 0 deg. AOA. The reference had a 53-cm-chord and the scale, 27 cm (1/2 size). Both models were mounted vertically in the center of the IRT test section. Tests covered a freezing fraction range of 0.28 to 1.0. Rime ice (n = 1.0) tests showed the consistency of the IRT calibration over a range of velocities. At a freezing fraction of 0.76, there was no significant difference in the scale ice shapes produced by the different methods. For freezing fractions of 0.40, 0.52 and 0.61, somewhat better agreement with the reference horn angles was typically achieved with the average-velocity and constant-film thickness methods than when either of the two Weber numbers was matched to the reference value. At a freezing fraction of 0.28, the four methods were judged equal in providing simulations of the reference shape.

  9. Systematic review of serum steroid reference intervals developed using mass spectrometry.

    PubMed

    Tavita, Nevada; Greaves, Ronda F

    2017-12-01

    The aim of this study was to perform a systematic review of the published literature to determine the available serum/plasma steroid reference intervals generated by mass spectrometry (MS) methods across all age groups in healthy subjects and to suggest recommendations to achieve common MS based reference intervals for serum steroids. MEDLINE, EMBASE and PubMed databases were used to conduct a comprehensive search for English language, MS-based reference interval studies for serum/plasma steroids. Selection of steroids to include was based on those listed in the Royal College of Pathologists of Australasia Quality Assurance Programs, Chemical Pathology, Endocrine Program. This methodology has been registered onto the PROSPERO International prospective register of systematic reviews (ID number: CRD42015029637). After accounting for duplicates, a total of 60 manuscripts were identified through the search strategy. Following critical evaluation, a total of 16 studies were selected. Of the 16 studies, 12 reported reference intervals for testosterone, 11 for 17 hydroxy-progesterone, nine for androstenedione, six for cortisol, three for progesterone, two for dihydrotestosterone and only one for aldosterone and dehydroepiandrosterone sulphate. No studies established MS-based reference intervals for oestradiol. As far as we are aware, this report provides the first comparison of the peer reviewed literature for serum/plasma steroid reference intervals generated by MS-based methods. The reference intervals based on these published studies can be used to inform the process to develop common reference intervals, and agreed reporting units for mass spectrometry based steroid methods. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  10. Absolute Radiometric Calibration of Narrow-Swath Imaging Sensors with Reference to Non-Coincident Wide-Swath Sensors

    NASA Technical Reports Server (NTRS)

    McCorkel, Joel; Thome, Kurtis; Lockwood, Ronald

    2012-01-01

    An inter-calibration method is developed to provide absolute radiometric calibration of narrow-swath imaging sensors with reference to non-coincident wide-swath sensors. The method predicts at-sensor radiance using non-coincident imagery from the reference sensor and knowledge of spectral reflectance of the test site. The imagery of the reference sensor is restricted to acquisitions that provide similar view and solar illumination geometry to reduce uncertainties due to directional reflectance effects. Spectral reflectance of the test site is found with a simple iterative radiative transfer method using radiance values of a well-understood wide-swath sensor and spectral shape information based on historical ground-based measurements. At-sensor radiance is calculated for the narrow-swath sensor using this spectral reflectance and atmospheric parameters that are also based on historical in situ measurements. Results of the inter-calibration method show agreement on the 2 5 percent level in most spectral regions with the vicarious calibration technique relying on coincident ground-based measurements referred to as the reflectance-based approach. While the variability of the inter-calibration method based on non-coincident image pairs is significantly larger, results are consistent with techniques relying on in situ measurements. The method is also insensitive to spectral differences between the sensors by transferring to surface spectral reflectance prior to prediction of at-sensor radiance. The utility of this inter-calibration method is made clear by its flexibility to utilize image pairings with acquisition dates differing in excess of 30 days allowing frequent absolute calibration comparisons between wide- and narrow-swath sensors.

  11. Comparison of a novel strategy for the detection and isolation of Salmonella in shell eggs with the Food and Drug Administration Bacteriological Analytical Manual method.

    PubMed

    Zhang, Guodong; Thau, Eve; Brown, Eric W; Hammack, Thomas S

    2013-12-01

    The current FDA Bacteriological Analytical Manual (BAM) method for the detection of Salmonella in eggs requires 2 wk to complete. The objective of this project was to improve the BAM method for the detection and isolation of Salmonella in whole shell eggs. A novel protocol, using 1,000 g of liquid eggs for direct preenrichment with 2 L of tryptic soy broth (TSB) followed by enrichment using Rappaport-Vassiliadis and Tetrathionate broths, was compared with the standard BAM method, which requires 96 h room temperature incubation of whole shell egg samples followed by preenrichment in TSB supplemented with FeSO4. Four Salmonella ser. Enteritidis (4 phage types) and one Salmonella ser. Heidelberg isolates were used in the study. Bulk inoculated pooled liquid eggs, weighing 52 or 56 kg (approximately 1,100 eggs) were used in each trial. Twenty 1,000-g test portions were withdrawn from the pooled eggs for both the alternative and the reference methods. Test portions were inoculated with Salmonella at 1 to 5 cfu/1,000 g eggs. Two replicates were performed for each isolate. In the 8 trials conducted with Salmonella ser. Enteritidis, the alternative method was significantly (P < 0.05) more productive than the reference method in 3 trials, and significantly (P < 0.05) less productive than the reference method in 1 trial. There were no significant (P < 0.05) differences between the 2 methods for the other 4 trials. For Salmonella ser. Heidelberg, combined data from 2 trials showed the alternative method was significantly (P < 0.05) more efficient than the BAM method. We have concluded that the alternative method, described herein, has the potential to replace the current BAM culture method for detection and isolation of Salmonella from shell eggs based on the following factors: 1) the alternative method is 4 d shorter than the reference method; 2) it uses regular TSB instead of the more complicated TSB supplemented with FeSO4; and 3) it was equivalent or superior to the reference method in 9 out of 10 trials for the detection of Salmonella in shell eggs.

  12. Noise-free recovery of optodigital encrypted and multiplexed images.

    PubMed

    Henao, Rodrigo; Rueda, Edgar; Barrera, John F; Torroba, Roberto

    2010-02-01

    We present a method that allows storing multiple encrypted data using digital holography and a joint transform correlator architecture with a controllable angle reference wave. In this method, the information is multiplexed by using a key and a different reference wave angle for each object. In the recovering process, the use of different reference wave angles prevents noise produced by the nonrecovered objects from being superimposed on the recovered object; moreover, the position of the recovered object in the exit plane can be fully controlled. We present the theoretical analysis and the experimental results that show the potential and applicability of the method.

  13. DNA-Based Methods in the Immunohematology Reference Laboratory

    PubMed Central

    Denomme, Gregory A

    2010-01-01

    Although hemagglutination serves the immunohematology reference laboratory well, when used alone, it has limited capability to resolve complex problems. This overview discusses how molecular approaches can be used in the immunohematology reference laboratory. In order to apply molecular approaches to immunohematology, knowledge of genes, DNA-based methods, and the molecular bases of blood groups are required. When applied correctly, DNA-based methods can predict blood groups to resolve ABO/Rh discrepancies, identify variant alleles, and screen donors for antigen-negative units. DNA-based testing in immunohematology is a valuable tool used to resolve blood group incompatibilities and to support patients in their transfusion needs. PMID:21257350

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Daleu, C. L.; Plant, R. S.; Woolnough, S. J.

    Here, as part of an international intercomparison project, a set of single-column models (SCMs) and cloud-resolving models (CRMs) are run under the weak-temperature gradient (WTG) method and the damped gravity wave (DGW) method. For each model, the implementation of the WTG or DGW method involves a simulated column which is coupled to a reference state defined with profiles obtained from the same model in radiative-convective equilibrium. The simulated column has the same surface conditions as the reference state and is initialized with profiles from the reference state. We performed systematic comparison of the behavior of different models under a consistentmore » implementation of the WTG method and the DGW method and systematic comparison of the WTG and DGW methods in models with different physics and numerics. CRMs and SCMs produce a variety of behaviors under both WTG and DGW methods. Some of the models reproduce the reference state while others sustain a large-scale circulation which results in either substantially lower or higher precipitation compared to the value of the reference state. CRMs show a fairly linear relationship between precipitation and circulation strength. SCMs display a wider range of behaviors than CRMs. Some SCMs under the WTG method produce zero precipitation. Within an individual SCM, a DGW simulation and a corresponding WTG simulation can produce different signed circulation. When initialized with a dry troposphere, DGW simulations always result in a precipitating equilibrium state. The greatest sensitivities to the initial moisture conditions occur for multiple stable equilibria in some WTG simulations, corresponding to either a dry equilibrium state when initialized as dry or a precipitating equilibrium state when initialized as moist. Multiple equilibria are seen in more WTG simulations for higher SST. In some models, the existence of multiple equilibria is sensitive to some parameters in the WTG calculations.« less

  15. MOISTURE IN COTTON BY THE KARL FISCHER TITRATION REFERENCE METHOD

    USDA-ARS?s Scientific Manuscript database

    Moisture is a critical parameter that influences many aspects of cotton fiber from harvesting and ginning to various fiber properties. Because of their importance, reference moisture methods that are more accurate than the existing oven-drying techniques and relatively easy to generate results are ...

  16. 40 CFR 761.19 - References.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... incorporated by reference, and is available for inspection at the National Archives and Records Administration...://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. These incorporations... Products (General Bomb Method) § 761.71(b)(2)(vi) ASTM D 240-87 Standard Test Method for Heat of Combustion...

  17. Calibration of BCR-ABL1 mRNA quantification methods using genetic reference materials is a valid strategy to report results on the international scale.

    PubMed

    Mauté, Carole; Nibourel, Olivier; Réa, Delphine; Coiteux, Valérie; Grardel, Nathalie; Preudhomme, Claude; Cayuela, Jean-Michel

    2014-09-01

    Until recently, diagnostic laboratories that wanted to report on the international scale had limited options: they had to align their BCR-ABL1 quantification methods through a sample exchange with a reference laboratory to derive a conversion factor. However, commercial methods calibrated on the World Health Organization genetic reference panel are now available. We report results from a study designed to assess the comparability of the two alignment strategies. Sixty follow-up samples from chronic myeloid leukemia patients were included. Two commercial methods calibrated on the genetic reference panel were compared to two conversion factor methods routinely used at Saint-Louis Hospital, Paris, and at Lille University Hospital. Results were matched against concordance criteria (i.e., obtaining at least two of the three following landmarks: 50, 75 and 90% of the patient samples within a 2-fold, 3-fold and 5-fold range, respectively). Out of the 60 samples, more than 32 were available for comparison. Compared to the conversion factor method, the two commercial methods were within a 2-fold, 3-fold and 5-fold range for 53 and 59%, 89 and 88%, 100 and 97%, respectively of the samples analyzed at Saint-Louis. At Lille, results were 45 and 85%, 76 and 97%, 100 and 100%, respectively. Agreements between methods were observed in the four comparisons performed. Our data show that the two commercial methods selected are concordant with the conversion factor methods. This study brings the proof of principle that alignment on the international scale using the genetic reference panel is compatible with the patient sample exchange procedure. We believe that these results are particularly important for diagnostic laboratories wishing to adopt commercial methods. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  18. Method modification of the Legipid® Legionella fast detection test kit.

    PubMed

    Albalat, Guillermo Rodríguez; Broch, Begoña Bedrina; Bono, Marisa Jiménez

    2014-01-01

    Legipid(®) Legionella Fast Detection is a test based on combined magnetic immunocapture and enzyme-immunoassay (CEIA) for the detection of Legionella in water. The test is based on the use of anti-Legionella antibodies immobilized on magnetic microspheres. Target microorganism is preconcentrated by filtration. Immunomagnetic analysis is applied on these preconcentrated water samples in a final test portion of 9 mL. The test kit was certified by the AOAC Research Institute as Performance Tested Method(SM) (PTM) No. 111101 in a PTM validation which certifies the performance claims of the test method in comparison to the ISO reference method 11731-1998 and the revision 11731-2004 "Water Quality: Detection and Enumeration of Legionella pneumophila" in potable water, industrial water, and waste water. The modification of this test kit has been approved. The modification includes increasing the target analyte from L. pneumophila to Legionella species and adding an optical reader to the test method. In this study, 71 strains of Legionella spp. other than L. pneumophila were tested to determine its reactivity with the kit based on CEIA. All the strains of Legionella spp. tested by the CEIA test were confirmed positive by reference standard method ISO 11731. This test (PTM 111101) has been modified to include a final optical reading. A methods comparison study was conducted to demonstrate the equivalence of this modification to the reference culture method. Two water matrixes were analyzed. Results show no statistically detectable difference between the test method and the reference culture method for the enumeration of Legionella spp. The relative level of detection was 93 CFU/volume examined (LOD50). For optical reading, the LOD was 40 CFU/volume examined and the LOQ was 60 CFU/volume examined. Results showed that the test Legipid Legionella Fast Detection is equivalent to the reference culture method for the enumeration of Legionella spp.

  19. Reference Intervals of Hematology and Clinical Chemistry Analytes for 1-Year-Old Korean Children.

    PubMed

    Lee, Hye Ryun; Shin, Sue; Yoon, Jong Hyun; Roh, Eun Youn; Chang, Ju Young

    2016-09-01

    Reference intervals need to be established according to age. We established reference intervals of hematology and chemistry from community-based healthy 1-yr-old children and analyzed their iron status according to the feeding methods during the first six months after birth. A total of 887 children who received a medical check-up between 2010 and 2014 at Boramae Hospital (Seoul, Korea) were enrolled. A total of 534 children (247 boys and 287 girls) were enrolled as reference individuals after the exclusion of data obtained from children with suspected iron deficiency. Hematology and clinical chemistry analytes were measured, and the reference value of each analyte was estimated by using parametric (mean±2 SD) or nonparametric methods (2.5-97.5th percentile). Iron, total iron-binding capacity, and ferritin were measured, and transferrin saturation was calculated. As there were no differences in the mean values between boys and girls, we established the reference intervals for 1-yr-old children regardless of sex. The analysis of serum iron status according to feeding methods during the first six months revealed higher iron, ferritin, and transferrin saturation levels in children exclusively or mainly fed formula than in children exclusively or mainly fed breast milk. We established reference intervals of hematology and clinical chemistry analytes from community-based healthy children at one year of age. These reference intervals will be useful for interpreting results of medical check-ups at one year of age.

  20. Study of the viscosity of hydrocarbon mixtures under pressure and temperature: A critical model of the corresponding states to double reference in the modeling domain.

    NASA Astrophysics Data System (ADS)

    Ettahir, Aziz; Boned, Christian; Lagourette, Bernard; Kettani, Kamal; Amarrayi, Khaoula; Garoumi, Mohammed

    2017-10-01

    The studied predictive model of behavior viscosimetric is the model of K.A. Petersen [1]. The dominant idea of this method is to characterize the viscosity of a fluid from two models taken as a reference in passing through a reduced pressure. The method is corresponding state with two references. This study shows that this method is dependent on the choice of reference and for each of the possibilities of C10/C6H6 and C1/C10 references . The results were investigated for four different weight ratios. It shows that the introduction of an adjusted coefficient does not improve significantly compared to results without adjustment factor, which appears to be the best choice. Regarding the influence of the choice of references, generally the two couples appear suitable but we noted that the choice is not necessary. In the case of mixtures containing at least one aromatic, the results are correct, especially if one takes the ratio of adjustment and our ratio without adjustment compared to that of K. A. PETERSEN[1]. The experimental results of the viscosity exhibit a good agreement with the calculated values. We can predict that the relative improvement is the finding that the introduction of the second body of reference (C10) from the model states corresponding to a reference (C1) of the authors.

  1. Fire danger rating over Mediterranean Europe based on fire radiative power derived from Meteosat

    NASA Astrophysics Data System (ADS)

    Pinto, Miguel M.; DaCamara, Carlos C.; Trigo, Isabel F.; Trigo, Ricardo M.; Feridun Turkman, K.

    2018-02-01

    We present a procedure that allows the operational generation of daily forecasts of fire danger over Mediterranean Europe. The procedure combines historical information about radiative energy released by fire events with daily meteorological forecasts, as provided by the Satellite Application Facility for Land Surface Analysis (LSA SAF) and the European Centre for Medium-Range Weather Forecasts (ECMWF). Fire danger is estimated based on daily probabilities of exceedance of daily energy released by fires occurring at the pixel level. Daily probability considers meteorological factors by means of the Canadian Fire Weather Index (FWI) and is estimated using a daily model based on a generalized Pareto distribution. Five classes of fire danger are then associated with daily probability estimated by the daily model. The model is calibrated using 13 years of data (2004-2016) and validated against the period of January-September 2017. Results obtained show that about 72 % of events releasing daily energy above 10 000 GJ belong to the extreme class of fire danger, a considerably high fraction that is more than 1.5 times the values obtained when using the currently operational Fire Danger Forecast module of the European Forest Fire Information System (EFFIS) or the Fire Risk Map (FRM) product disseminated by the LSA SAF. Besides assisting in wildfire management, the procedure is expected to help in decision making on prescribed burning within the framework of agricultural and forest management practices.

  2. [Research of Odo Bujwid (1857-1942) concerning the vaccine against rabies-historical characterisation].

    PubMed

    Wasiewicz, Barbara

    2016-01-01

    The present article refers to the historical characterisation of Odo Bujwid's (1857-1942) research concerning the vaccine against rabies. The introduction refers to the treatment methods applied before Ludwik Pasteur's discovery. The following part refers to Odo Bujwid's own research including diagnostics, characterisation of the symptoms of disease, modification of the original Ludwik Pasteur's method and statistical information. The resume emphasizes that Odo Bujwid's scientific research was the introduction and generalisation the worldwide microbiology knowledge at the polish lands.

  3. Carrier phase synchronization system for improved amplitude modulation and television broadcast reception

    DOEpatents

    Smith, Stephen F [Loudon, TN; Moore, James A [Powell, TN

    2011-02-01

    Systems and methods are described for carrier phase synchronization for improved AM and TV broadcast reception. A method includes synchronizing the phase of a carrier frequency of a broadcast signal with the phase of a remote reference frequency. An apparatus includes a receiver to detect the phase of a reference signal; a phase comparator coupled to the reference signal-phase receiver; a voltage controlled oscillator coupled to the phase comparator; and a phase-controlled radio frequency output coupled to the voltage controlled oscillator.

  4. Accuracy of two geocoding methods for geographic information system-based exposure assessment in epidemiological studies.

    PubMed

    Faure, Elodie; Danjou, Aurélie M N; Clavel-Chapelon, Françoise; Boutron-Ruault, Marie-Christine; Dossus, Laure; Fervers, Béatrice

    2017-02-24

    Environmental exposure assessment based on Geographic Information Systems (GIS) and study participants' residential proximity to environmental exposure sources relies on the positional accuracy of subjects' residences to avoid misclassification bias. Our study compared the positional accuracy of two automatic geocoding methods to a manual reference method. We geocoded 4,247 address records representing the residential history (1990-2008) of 1,685 women from the French national E3N cohort living in the Rhône-Alpes region. We compared two automatic geocoding methods, a free-online geocoding service (method A) and an in-house geocoder (method B), to a reference layer created by manually relocating addresses from method A (method R). For each automatic geocoding method, positional accuracy levels were compared according to the urban/rural status of addresses and time-periods (1990-2000, 2001-2008), using Chi Square tests. Kappa statistics were performed to assess agreement of positional accuracy of both methods A and B with the reference method, overall, by time-periods and by urban/rural status of addresses. Respectively 81.4% and 84.4% of addresses were geocoded to the exact address (65.1% and 61.4%) or to the street segment (16.3% and 23.0%) with methods A and B. In the reference layer, geocoding accuracy was higher in urban areas compared to rural areas (74.4% vs. 10.5% addresses geocoded to the address or interpolated address level, p < 0.0001); no difference was observed according to the period of residence. Compared to the reference method, median positional errors were 0.0 m (IQR = 0.0-37.2 m) and 26.5 m (8.0-134.8 m), with positional errors <100 m for 82.5% and 71.3% of addresses, for method A and method B respectively. Positional agreement of method A and method B with method R was 'substantial' for both methods, with kappa coefficients of 0.60 and 0.61 for methods A and B, respectively. Our study demonstrates the feasibility of geocoding residential addresses in epidemiological studies not initially recorded for environmental exposure assessment, for both recent addresses and residence locations more than 20 years ago. Accuracy of the two automatic geocoding methods was comparable. The in-house method (B) allowed a better control of the geocoding process and was less time consuming.

  5. Reference Accuracy among Research Articles Published in "Research on Social Work Practice"

    ERIC Educational Resources Information Center

    Wilks, Scott E.; Geiger, Jennifer R.; Bates, Samantha M.; Wright, Amy L.

    2017-01-01

    Objective: The objective was to examine reference errors in research articles published in Research on Social Work Practice. High rates of reference errors in other top social work journals have been noted in previous studies. Methods: Via a sampling frame of 22,177 total references among 464 research articles published in the previous decade, a…

  6. Automating Reference Desk Files with Microcomputers in a Public Library: An Exploration of Data Resources, Methods, and Software.

    ERIC Educational Resources Information Center

    Miley, David W.

    Many reference librarians still rely on manual searches to access vertical files, ready reference files, and other information stored in card files, drawers, and notebooks scattered around the reference department. Automated access to these materials via microcomputers using database management software may speed up the process. This study focuses…

  7. Serum TSH reference interval in healthy Finnish adults using the Abbott Architect 2000i Analyzer.

    PubMed

    Schalin-Jäntti, Camilla; Tanner, Pirjo; Välimäki, Matti J; Hämäläinen, Esa

    2011-07-01

    Current serum TSH reference intervals have been criticized as they were established from unselected background populations. A special concern is that the upper limit, which defines subclinical hypothyroidism, is too high. The objective was to redefine the TSH reference interval in the adult Finnish population. The current reference interval for the widely used Abbott Architect method in Finland is 0.4-4.0 mU/L. Serum TSH and free T4 concentrations were derived from 606 healthy, non-pregnant, 18-91-year-old Finns from the Nordic Reference Interval Project (NORIP) and the possible effects of age, sex and thyroid peroxidase antibody (TPOAb) status were evaluated. After excluding TPOAb-positive subjects and outliers, a reference population of 511 subjects was obtained. In the reference population, no statistically significant gender- or age-specific differences in mean TSH (1.55 ± 3.30 mU/L) or TSH reference intervals were observed. The new reference interval was 0.5-3.6 mU/L (2.5th-97.5th percentiles). The current upper TSH reference limit is 10% too high. A TSH > 3.6 mU/L, confirmed with a repeat TSH sampling, may indicate subclinical hypothyroidism. Differences in ethnicity, regional iodine-intake and analytical methods underline the need for redefining the TSH reference interval in central laboratories in different countries.

  8. Ballistocardiogram as Proximal Timing Reference for Pulse Transit Time Measurement: Potential for Cuffless Blood Pressure Monitoring

    PubMed Central

    Kim, Chang-Sei; Carek, Andrew M.; Mukkamala, Ramakrishna; Inan, Omer T.; Hahn, Jin-Oh

    2015-01-01

    Goal We tested the hypothesis that the ballistocardiogram (BCG) waveform could yield a viable proximal timing reference for measuring pulse transit time (PTT). Methods From fifteen healthy volunteers, we measured PTT as the time interval between BCG and a non-invasively measured finger blood pressure (BP) waveform. To evaluate the efficacy of the BCG-based PTT in estimating BP, we likewise measured pulse arrival time (PAT) using the electrocardiogram (ECG) as proximal timing reference and compared their correlations to BP. Results BCG-based PTT was correlated with BP reasonably well: the mean correlation coefficient (r) was 0.62 for diastolic (DP), 0.65 for mean (MP) and 0.66 for systolic (SP) pressures when the intersecting tangent method was used as distal timing reference. Comparing four distal timing references (intersecting tangent, maximum second derivative, diastolic minimum and systolic maximum), PTT exhibited the best correlation with BP when the systolic maximum method was used (mean r value was 0.66 for DP, 0.67 for MP and 0.70 for SP). PTT was more strongly correlated with DP than PAT regardless of the distal timing reference: mean r value was 0.62 versus 0.51 (p=0.07) for intersecting tangent, 0.54 versus 0.49 (p=0.17) for maximum second derivative, 0.58 versus 0.52 (p=0.37) for diastolic minimum, and 0.66 versus 0.60 (p=0.10) for systolic maximum methods. The difference between PTT and PAT in estimating DP was significant (p=0.01) when the r values associated with all the distal timing references were compared altogether. However, PAT appeared to outperform PTT in estimating SP (p=0.31 when the r values associated with all the distal timing references were compared altogether). Conclusion We conclude that BCG is an adequate proximal timing reference in deriving PTT, and that BCG-based PTT may be superior to ECG-based PAT in estimating DP. Significance PTT with BCG as proximal timing reference has potential to enable convenient and ubiquitous cuffless BP monitoring. PMID:26054058

  9. Review of Federal Reference Method for Ozone: Nitric Oxide-Chemiluminescence:Supplemental Material for CASAC AMMS

    EPA Science Inventory

    ApproachPer suggestion made by CASAC AMMS members during the April 3, 2014 conference call on the Review of Federal Reference Method for Ozone: Nitric Oxide-Chemiluminescence, ORD has performed additional data analysis activities to explain and mitigate scatter observed in the co...

  10. 77 FR 14814 - Tobacco Product Analysis; Scientific Workshop; Request for Comments

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-13

    ... work to develop tobacco reference products that are not currently available for laboratory use. Discuss... methods used to analyze tobacco products. FDA will invite speakers to address scientific and technical matters relating to the testing of tobacco reference products and the analytical methods used to measure...

  11. 40 CFR 92.5 - Reference materials.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...: (1) ASTM material. The following table sets forth material from the American Society for Testing and...., Philadelphia, PA 19103. The table follows: Document number and name 40 CFR part 92 reference ASTM D 86-95, Standard Test Method for Distillation of Petroleum Products § 92.113 ASTM D 93-94, Standard Test Methods...

  12. 40 CFR 53.4 - Applications for reference or equivalent method determinations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... using information such as service reports and customer complaints to eliminate potential causes of... standards of good practice and by qualified personnel. Test anomalies or irregularities shall be documented... designated as a reference or equivalent method, to ensure that all analyzers or samplers offered for sale...

  13. 40 CFR 98.254 - Monitoring and QA/QC requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Bomb Calorimeter (Precision Method) (incorporated by reference, see § 98.7). (2) ASTM D240-02 (Reapproved 2007) Standard Test Method for Heat of Combustion of Liquid Hydrocarbon Fuels by Bomb Calorimeter... Carbon, Hydrogen, and Nitrogen in Petroleum Products and Lubricants (incorporated by reference, see § 98...

  14. 40 CFR 98.254 - Monitoring and QA/QC requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Bomb Calorimeter (Precision Method) (incorporated by reference, see § 98.7). (2) ASTM D240-02 (Reapproved 2007) Standard Test Method for Heat of Combustion of Liquid Hydrocarbon Fuels by Bomb Calorimeter... Carbon, Hydrogen, and Nitrogen in Petroleum Products and Lubricants (incorporated by reference, see § 98...

  15. 40 CFR 98.254 - Monitoring and QA/QC requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Bomb Calorimeter (Precision Method) (incorporated by reference, see § 98.7). (2) ASTM D240-02 (Reapproved 2007) Standard Test Method for Heat of Combustion of Liquid Hydrocarbon Fuels by Bomb Calorimeter... Carbon, Hydrogen, and Nitrogen in Petroleum Products and Lubricants (incorporated by reference, see § 98...

  16. Identification and validation of suitable reference genes for RT-qPCR analysis in mouse testis development.

    PubMed

    Gong, Zu-Kang; Wang, Shuang-Jie; Huang, Yong-Qi; Zhao, Rui-Qiang; Zhu, Qi-Fang; Lin, Wen-Zhen

    2014-12-01

    RT-qPCR is a commonly used method for evaluating gene expression; however, its accuracy and reliability are dependent upon the choice of appropriate reference gene(s), and there is limited information available on suitable reference gene(s) that can be used in mouse testis at different stages. In this study, using the RT-qPCR method, we investigated the expression variations of six reference genes representing different functional classes (Actb, Gapdh, Ppia, Tbp, Rps29, Hprt1) in mice testis during embryonic and postnatal development. The expression stabilities of putative reference genes were evaluated using five algorithms: geNorm, NormFinder, Bestkeeper, the comparative delta C(t) method and integrated tool RefFinder. Analysis of the results showed that Ppia, Gapdh and Actb were identified as the most stable genes and the geometric mean of Ppia, Gapdh and Actb constitutes an appropriate normalization factor for gene expression studies. The mRNA expression of AT1 as a test gene of interest varied depending upon which of the reference gene(s) was used as an internal control(s). This study suggested that Ppia, Gapdh and Actb are suitable reference genes among the six genes used for RT-qPCR normalization and provide crucial information for transcriptional analyses in future studies of gene expression in the developing mouse testis.

  17. Psi4NumPy: An Interactive Quantum Chemistry Programming Environment for Reference Implementations and Rapid Development.

    PubMed

    Smith, Daniel G A; Burns, Lori A; Sirianni, Dominic A; Nascimento, Daniel R; Kumar, Ashutosh; James, Andrew M; Schriber, Jeffrey B; Zhang, Tianyuan; Zhang, Boyi; Abbott, Adam S; Berquist, Eric J; Lechner, Marvin H; Cunha, Leonardo A; Heide, Alexander G; Waldrop, Jonathan M; Takeshita, Tyler Y; Alenaizan, Asem; Neuhauser, Daniel; King, Rollin A; Simmonett, Andrew C; Turney, Justin M; Schaefer, Henry F; Evangelista, Francesco A; DePrince, A Eugene; Crawford, T Daniel; Patkowski, Konrad; Sherrill, C David

    2018-06-11

    Psi4NumPy demonstrates the use of efficient computational kernels from the open-source Psi4 program through the popular NumPy library for linear algebra in Python to facilitate the rapid development of clear, understandable Python computer code for new quantum chemical methods, while maintaining a relatively low execution time. Using these tools, reference implementations have been created for a number of methods, including self-consistent field (SCF), SCF response, many-body perturbation theory, coupled-cluster theory, configuration interaction, and symmetry-adapted perturbation theory. Furthermore, several reference codes have been integrated into Jupyter notebooks, allowing background, underlying theory, and formula information to be associated with the implementation. Psi4NumPy tools and associated reference implementations can lower the barrier for future development of quantum chemistry methods. These implementations also demonstrate the power of the hybrid C++/Python programming approach employed by the Psi4 program.

  18. Woodstove smoke and CO emissions: comparison of reference methods with the VIP sampler.

    PubMed

    Jaasma, D R; Champion, M C; Shelton, J W

    1990-06-01

    A new field sampler has been developed for measuring the particulate matter (PM) and carbon monoxide emissions of woodburning stoves. Particulate matter is determined by carbon balance and the workup of a sample train which is similar to a room-temperature EPA Method 5G train. A steel tank, initially evacuated, serves as the motive force for sampling and also accumulates a gas sample for post-test analysis of time-averaged stack CO and CO2 concentrations. Workup procedures can be completed within 72 hours of sampler retrieval. The system has been compared to reference methods in two laboratory test series involving six different woodburning appliances and two independent laboratories. The correlation of field sampler emission rates and reference method rates is strong.

  19. Woodstove smoke and CO emissions: Comparison of reference methods with the VIP sampler

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jaasma, D.R.; Champion, M.C.; Shelton, J.W.

    1990-06-01

    A new field sampler has been developed for measuring the particulate matter (PM) and carbon monoxide emissions of woodburning stoves. Particulate matter is determined by carbon balance and the workup of a sample train which is similar to a room-temperature EPA Method 5G train. A steel tank, initially evacuated, serves as the motive force for sampling and also accumulates a gas sample for post-test analysis of time-averaged stack CO and CO{sub 2} concentrations. Workup procedures can be completed within 72 hours of sampler retrieval. The system has been compared to reference methods in two laboratory test series involving six differentmore » woodburning appliances and two independent laboratories. The correlation of field sampler emission rates and reference method rates is strong.« less

  20. Comparison of ambulatory blood pressure reference standards in children evaluated for hypertension

    PubMed Central

    Jones, Deborah P.; Richey, Phyllis A.; Alpert, Bruce S.

    2009-01-01

    Objective The purpose of this study was to systematically compare methods for standardization of blood pressure levels obtained by ambulatory blood pressure monitoring (ABPM) in a group of 111 children studied at our institution. Methods Blood pressure indices, blood pressure loads and standard deviation scores were calculated using he original ABPM and the modified reference standards. Bland—Altman plots and kappa statistics for the level of agreement were generated. Results Overall, the agreement between the two methods was excellent; however, approximately 5% of children were classified differently by one as compared with the other method. Conclusion Depending on which version of the German Working Group’s reference standards is used for interpretation of ABPM data, the classification of the individual as having hypertension or normal blood pressure may vary. PMID:19433980

  1. Method and apparatus for measuring low currents in capacitance devices

    DOEpatents

    Kopp, M.K.; Manning, F.W.; Guerrant, G.C.

    1986-06-04

    A method and apparatus for measuring subnanoampere currents in capacitance devices is reported. The method is based on a comparison of the voltages developed across the capacitance device with that of a reference capacitor in which the current is adjusted by means of a variable current source to produce a stable voltage difference. The current varying means of the variable current source is calibrated to provide a read out of the measured current. Current gain may be provided by using a reference capacitor which is larger than the device capacitance with a corresponding increase in current supplied through the reference capacitor. The gain is then the ratio of the reference capacitance to the device capacitance. In one illustrated embodiment, the invention makes possible a new type of ionizing radiation dose-rate monitor where dose-rate is measured by discharging a reference capacitor with a variable current source at the same rate that radiation is discharging an ionization chamber. The invention eliminates high-megohm resistors and low current ammeters used in low-current measuring instruments.

  2. Fast and accurate genotype imputation in genome-wide association studies through pre-phasing

    PubMed Central

    Howie, Bryan; Fuchsberger, Christian; Stephens, Matthew; Marchini, Jonathan; Abecasis, Gonçalo R.

    2013-01-01

    Sequencing efforts, including the 1000 Genomes Project and disease-specific efforts, are producing large collections of haplotypes that can be used for genotype imputation in genome-wide association studies (GWAS). Imputing from these reference panels can help identify new risk alleles, but the use of large panels with existing methods imposes a high computational burden. To keep imputation broadly accessible, we introduce a strategy called “pre-phasing” that maintains the accuracy of leading methods while cutting computational costs by orders of magnitude. In brief, we first statistically estimate the haplotypes for each GWAS individual (“pre-phasing”) and then impute missing genotypes into these estimated haplotypes. This reduces the computational cost because: (i) the GWAS samples must be phased only once, whereas standard methods would implicitly re-phase with each reference panel update; (ii) it is much faster to match a phased GWAS haplotype to one reference haplotype than to match unphased GWAS genotypes to a pair of reference haplotypes. This strategy will be particularly valuable for repeated imputation as reference panels evolve. PMID:22820512

  3. Automatic reference selection for quantitative EEG interpretation: identification of diffuse/localised activity and the active earlobe reference, iterative detection of the distribution of EEG rhythms.

    PubMed

    Wang, Bei; Wang, Xingyu; Ikeda, Akio; Nagamine, Takashi; Shibasaki, Hiroshi; Nakamura, Masatoshi

    2014-01-01

    EEG (Electroencephalograph) interpretation is important for the diagnosis of neurological disorders. The proper adjustment of the montage can highlight the EEG rhythm of interest and avoid false interpretation. The aim of this study was to develop an automatic reference selection method to identify a suitable reference. The results may contribute to the accurate inspection of the distribution of EEG rhythms for quantitative EEG interpretation. The method includes two pre-judgements and one iterative detection module. The diffuse case is initially identified by pre-judgement 1 when intermittent rhythmic waveforms occur over large areas along the scalp. The earlobe reference or averaged reference is adopted for the diffuse case due to the effect of the earlobe reference depending on pre-judgement 2. An iterative detection algorithm is developed for the localised case when the signal is distributed in a small area of the brain. The suitable averaged reference is finally determined based on the detected focal and distributed electrodes. The presented technique was applied to the pathological EEG recordings of nine patients. One example of the diffuse case is introduced by illustrating the results of the pre-judgements. The diffusely intermittent rhythmic slow wave is identified. The effect of active earlobe reference is analysed. Two examples of the localised case are presented, indicating the results of the iterative detection module. The focal and distributed electrodes are detected automatically during the repeating algorithm. The identification of diffuse and localised activity was satisfactory compared with the visual inspection. The EEG rhythm of interest can be highlighted using a suitable selected reference. The implementation of an automatic reference selection method is helpful to detect the distribution of an EEG rhythm, which can improve the accuracy of EEG interpretation during both visual inspection and automatic interpretation. Copyright © 2013 IPEM. Published by Elsevier Ltd. All rights reserved.

  4. Interagency comparison of iodometric methods for ozone determination

    NASA Technical Reports Server (NTRS)

    Demore, W. B.; Romanovsky, J. C.; Feldstein, M.; Mueller, P. K.; Hamming, W. J.

    1976-01-01

    The California Air Resources Board appointed an Oxidant Calibration Committee for the purpose of evaluating the accuracy of the different agency calibration procedures. The committee chose UV absorption photometry as the reference method for ozone measurement. Interagency comparisons of the various iodometric methods were conducted relative to the ultraviolet standard. The tests included versions of the iodometric methods as employed by the Air Resources Board, the Los Angeles Air Pollution Control District, and the EPA. An alternative candidate reference method for ozone measurement, gas phase titration, was also included in the test series.

  5. Research on Multi - Person Parallel Modeling Method Based on Integrated Model Persistent Storage

    NASA Astrophysics Data System (ADS)

    Qu, MingCheng; Wu, XiangHu; Tao, YongChao; Liu, Ying

    2018-03-01

    This paper mainly studies the multi-person parallel modeling method based on the integrated model persistence storage. The integrated model refers to a set of MDDT modeling graphics system, which can carry out multi-angle, multi-level and multi-stage description of aerospace general embedded software. Persistent storage refers to converting the data model in memory into a storage model and converting the storage model into a data model in memory, where the data model refers to the object model and the storage model is a binary stream. And multi-person parallel modeling refers to the need for multi-person collaboration, the role of separation, and even real-time remote synchronization modeling.

  6. Bounded Linear Stability Analysis - A Time Delay Margin Estimation Approach for Adaptive Control

    NASA Technical Reports Server (NTRS)

    Nguyen, Nhan T.; Ishihara, Abraham K.; Krishnakumar, Kalmanje Srinlvas; Bakhtiari-Nejad, Maryam

    2009-01-01

    This paper presents a method for estimating time delay margin for model-reference adaptive control of systems with almost linear structured uncertainty. The bounded linear stability analysis method seeks to represent the conventional model-reference adaptive law by a locally bounded linear approximation within a small time window using the comparison lemma. The locally bounded linear approximation of the combined adaptive system is cast in a form of an input-time-delay differential equation over a small time window. The time delay margin of this system represents a local stability measure and is computed analytically by a matrix measure method, which provides a simple analytical technique for estimating an upper bound of time delay margin. Based on simulation results for a scalar model-reference adaptive control system, both the bounded linear stability method and the matrix measure method are seen to provide a reasonably accurate and yet not too conservative time delay margin estimation.

  7. Nonparametric spirometry reference values for Hispanic Americans.

    PubMed

    Glenn, Nancy L; Brown, Vanessa M

    2011-02-01

    Recent literature sites ethnic origin as a major factor in developing pulmonary function reference values. Extensive studies established reference values for European and African Americans, but not for Hispanic Americans. The Third National Health and Nutrition Examination Survey defines Hispanic as individuals of Spanish speaking cultures. While no group was excluded from the target population, sample size requirements only allowed inclusion of individuals who identified themselves as Mexican Americans. This research constructs nonparametric reference value confidence intervals for Hispanic American pulmonary function. The method is applicable to all ethnicities. We use empirical likelihood confidence intervals to establish normal ranges for reference values. Its major advantage: it is model free, but shares asymptotic properties of model based methods. Statistical comparisons indicate that empirical likelihood interval lengths are comparable to normal theory intervals. Power and efficiency studies agree with previously published theoretical results.

  8. Certification of biological candidates reference materials by neutron activation analysis

    NASA Astrophysics Data System (ADS)

    Kabanov, Denis V.; Nesterova, Yulia V.; Merkulov, Viktor G.

    2018-03-01

    The paper gives the results of interlaboratory certification of new biological candidate reference materials by neutron activation analysis recommended by the Institute of Nuclear Chemistry and Technology (Warsaw, Poland). The correctness and accuracy of the applied method was statistically estimated for the determination of trace elements in candidate reference materials. The procedure of irradiation in the reactor thermal fuel assembly without formation of fast neutrons was carried out. It excluded formation of interfering isotopes leading to false results. The concentration of more than 20 elements (e.g., Ba, Br, Ca, Co, Ce, Cr, Cs, Eu, Fe, Hf, La, Lu, Rb, Sb, Sc, Ta, Th, Tb, Yb, U, Zn) in candidate references of tobacco leaves and bottom sediment compared to certified reference materials were determined. It was shown that the average error of the applied method did not exceed 10%.

  9. Micro methods and micro apparatus for chemical pathology with special reference to paediatrics

    PubMed Central

    Clayton, Barbara E.; Jenkins, P.

    1966-01-01

    This article describes methods and apparatus which permit the estimation of a particular substance without requiring more blood than can conveniently and safely be removed from a child by capillary puncture. No reference will be made to the use of methods on the Technicon Auto-Analyzer as that machine is not yet generally geared to paediatric work, although a few centres have made their own modifications to permit certain methods to be performed on capillary samples of blood. PMID:5937614

  10. Nationwide Multicenter Reference Interval Study for 28 Common Biochemical Analytes in China.

    PubMed

    Xia, Liangyu; Chen, Ming; Liu, Min; Tao, Zhihua; Li, Shijun; Wang, Liang; Cheng, Xinqi; Qin, Xuzhen; Han, Jianhua; Li, Pengchang; Hou, Li'an; Yu, Songlin; Ichihara, Kiyoshi; Qiu, Ling

    2016-03-01

    A nationwide multicenter study was conducted in the China to explore sources of variation of reference values and establish reference intervals for 28 common biochemical analytes, as a part of the International Federation of Clinical Chemistry and Laboratory Medicine, Committee on Reference Intervals and Decision Limits (IFCC/C-RIDL) global study on reference values. A total of 3148 apparently healthy volunteers were recruited in 6 cities covering a wide area in China. Blood samples were tested in 2 central laboratories using Beckman Coulter AU5800 chemistry analyzers. Certified reference materials and value-assigned serum panel were used for standardization of test results. Multiple regression analysis was performed to explore sources of variation. Need for partition of reference intervals was evaluated based on 3-level nested ANOVA. After secondary exclusion using the latent abnormal values exclusion method, reference intervals were derived by a parametric method using the modified Box-Cox formula. Test results of 20 analytes were made traceable to reference measurement procedures. By the ANOVA, significant sex-related and age-related differences were observed in 12 and 12 analytes, respectively. A small regional difference was observed in the results for albumin, glucose, and sodium. Multiple regression analysis revealed BMI-related changes in results of 9 analytes for man and 6 for woman. Reference intervals of 28 analytes were computed with 17 analytes partitioned by sex and/or age. In conclusion, reference intervals of 28 common chemistry analytes applicable to Chinese Han population were established by use of the latest methodology. Reference intervals of 20 analytes traceable to reference measurement procedures can be used as common reference intervals, whereas others can be used as the assay system-specific reference intervals in China.

  11. Nationwide Multicenter Reference Interval Study for 28 Common Biochemical Analytes in China

    PubMed Central

    Xia, Liangyu; Chen, Ming; Liu, Min; Tao, Zhihua; Li, Shijun; Wang, Liang; Cheng, Xinqi; Qin, Xuzhen; Han, Jianhua; Li, Pengchang; Hou, Li’an; Yu, Songlin; Ichihara, Kiyoshi; Qiu, Ling

    2016-01-01

    Abstract A nationwide multicenter study was conducted in the China to explore sources of variation of reference values and establish reference intervals for 28 common biochemical analytes, as a part of the International Federation of Clinical Chemistry and Laboratory Medicine, Committee on Reference Intervals and Decision Limits (IFCC/C-RIDL) global study on reference values. A total of 3148 apparently healthy volunteers were recruited in 6 cities covering a wide area in China. Blood samples were tested in 2 central laboratories using Beckman Coulter AU5800 chemistry analyzers. Certified reference materials and value-assigned serum panel were used for standardization of test results. Multiple regression analysis was performed to explore sources of variation. Need for partition of reference intervals was evaluated based on 3-level nested ANOVA. After secondary exclusion using the latent abnormal values exclusion method, reference intervals were derived by a parametric method using the modified Box–Cox formula. Test results of 20 analytes were made traceable to reference measurement procedures. By the ANOVA, significant sex-related and age-related differences were observed in 12 and 12 analytes, respectively. A small regional difference was observed in the results for albumin, glucose, and sodium. Multiple regression analysis revealed BMI-related changes in results of 9 analytes for man and 6 for woman. Reference intervals of 28 analytes were computed with 17 analytes partitioned by sex and/or age. In conclusion, reference intervals of 28 common chemistry analytes applicable to Chinese Han population were established by use of the latest methodology. Reference intervals of 20 analytes traceable to reference measurement procedures can be used as common reference intervals, whereas others can be used as the assay system-specific reference intervals in China. PMID:26945390

  12. Using pseudoalignment and base quality to accurately quantify microbial community composition

    PubMed Central

    Novembre, John

    2018-01-01

    Pooled DNA from multiple unknown organisms arises in a variety of contexts, for example microbial samples from ecological or human health research. Determining the composition of pooled samples can be difficult, especially at the scale of modern sequencing data and reference databases. Here we propose a novel method for taxonomic profiling in pooled DNA that combines the speed and low-memory requirements of k-mer based pseudoalignment with a likelihood framework that uses base quality information to better resolve multiply mapped reads. We apply the method to the problem of classifying 16S rRNA reads using a reference database of known organisms, a common challenge in microbiome research. Using simulations, we show the method is accurate across a variety of read lengths, with different length reference sequences, at different sample depths, and when samples contain reads originating from organisms absent from the reference. We also assess performance in real 16S data, where we reanalyze previous genetic association data to show our method discovers a larger number of quantitative trait associations than other widely used methods. We implement our method in the software Karp, for k-mer based analysis of read pools, to provide a novel combination of speed and accuracy that is uniquely suited for enhancing discoveries in microbial studies. PMID:29659582

  13. Selection of suitable reference genes for gene expression studies in Staphylococcus capitis during growth under erythromycin stress.

    PubMed

    Cui, Bintao; Smooker, Peter M; Rouch, Duncan A; Deighton, Margaret A

    2016-08-01

    Accurate and reproducible measurement of gene transcription requires appropriate reference genes, which are stably expressed under different experimental conditions to provide normalization. Staphylococcus capitis is a human pathogen that produces biofilm under stress, such as imposed by antimicrobial agents. In this study, a set of five commonly used staphylococcal reference genes (gyrB, sodA, recA, tuf and rpoB) were systematically evaluated in two clinical isolates of Staphylococcus capitis (S. capitis subspecies urealyticus and capitis, respectively) under erythromycin stress in mid-log and stationary phases. Two public software programs (geNorm and NormFinder) and two manual calculation methods, reference residue normalization (RRN) and relative quantitative (RQ), were applied. The potential reference genes selected by the four algorithms were further validated by comparing the expression of a well-studied biofilm gene (icaA) with phenotypic biofilm formation in S. capitis under four different experimental conditions. The four methods differed considerably in their ability to predict the most suitable reference gene or gene combination for comparing icaA expression under different conditions. Under the conditions used here, the RQ method provided better selection of reference genes than the other three algorithms; however, this finding needs to be confirmed with a larger number of isolates. This study reinforces the need to assess the stability of reference genes for analysis of target gene expression under different conditions and the use of more than one algorithm in such studies. Although this work was conducted using a specific human pathogen, it emphasizes the importance of selecting suitable reference genes for accurate normalization of gene expression more generally.

  14. Accuracy of Referring Provider and Endoscopist Impressions of Colonoscopy Indication.

    PubMed

    Naveed, Mariam; Clary, Meredith; Ahn, Chul; Kubiliun, Nisa; Agrawal, Deepak; Cryer, Byron; Murphy, Caitlin; Singal, Amit G

    2017-07-01

    Background: Referring provider and endoscopist impressions of colonoscopy indication are used for clinical care, reimbursement, and quality reporting decisions; however, the accuracy of these impressions is unknown. This study assessed the sensitivity, specificity, positive and negative predictive value, and overall accuracy of methods to classify colonoscopy indication, including referring provider impression, endoscopist impression, and administrative algorithm compared with gold standard chart review. Methods: We randomly sampled 400 patients undergoing a colonoscopy at a Veterans Affairs health system between January 2010 and December 2010. Referring provider and endoscopist impressions of colonoscopy indication were compared with gold-standard chart review. Indications were classified into 4 mutually exclusive categories: diagnostic, surveillance, high-risk screening, or average-risk screening. Results: Of 400 colonoscopies, 26% were performed for average-risk screening, 7% for high-risk screening, 26% for surveillance, and 41% for diagnostic indications. Accuracy of referring provider and endoscopist impressions of colonoscopy indication were 87% and 84%, respectively, which were significantly higher than that of the administrative algorithm (45%; P <.001 for both). There was substantial agreement between endoscopist and referring provider impressions (κ=0.76). All 3 methods showed high sensitivity (>90%) for determining screening (vs nonscreening) indication, but specificity of the administrative algorithm was lower (40.3%) compared with referring provider (93.7%) and endoscopist (84.0%) impressions. Accuracy of endoscopist, but not referring provider, impression was lower in patients with a family history of colon cancer than in those without (65% vs 84%; P =.001). Conclusions: Referring provider and endoscopist impressions of colonoscopy indication are both accurate and may be useful data to incorporate into algorithms classifying colonoscopy indication. Copyright © 2017 by the National Comprehensive Cancer Network.

  15. Superconductor rotor cooling system

    DOEpatents

    Gamble, Bruce B.; Sidi-Yekhlef, Ahmed; Schwall, Robert E.; Driscoll, David I.; Shoykhet, Boris A.

    2004-11-02

    A system for cooling a superconductor device includes a cryocooler located in a stationary reference frame and a closed circulation system external to the cryocooler. The closed circulation system interfaces the stationary reference frame with a rotating reference frame in which the superconductor device is located. A method of cooling a superconductor device includes locating a cryocooler in a stationary reference frame, and transferring heat from a superconductor device located in a rotating reference frame to the cryocooler through a closed circulation system external to the cryocooler. The closed circulation system interfaces the stationary reference frame with the rotating reference frame.

  16. Superconductor rotor cooling system

    DOEpatents

    Gamble, Bruce B.; Sidi-Yekhlef, Ahmed; Schwall, Robert E.; Driscoll, David I.; Shoykhet, Boris A.

    2002-01-01

    A system for cooling a superconductor device includes a cryocooler located in a stationary reference frame and a closed circulation system external to the cryocooler. The closed circulation system interfaces the stationary reference frame with a rotating reference frame in which the superconductor device is located. A method of cooling a superconductor device includes locating a cryocooler in a stationary reference frame, and transferring heat from a superconductor device located in a rotating reference frame to the cryocooler through a closed circulation system external to the cryocooler. The closed circulation system interfaces the stationary reference frame with the rotating reference frame.

  17. Effect of defuzzification method of fuzzy modeling

    NASA Astrophysics Data System (ADS)

    Lapohos, Tibor; Buchal, Ralph O.

    1994-10-01

    Imprecision can arise in fuzzy relational modeling as a result of fuzzification, inference and defuzzification. These three sources of imprecision are difficult to separate. We have determined through numerical studies that an important source of imprecision is the defuzzification stage. This imprecision adversely affects the quality of the model output. The most widely used defuzzification algorithm is known by the name of `center of area' (COA) or `center of gravity' (COG). In this paper, we show that this algorithm not only maps the near limit values of the variables improperly but also introduces errors for middle domain values of the same variables. Furthermore, the behavior of this algorithm is a function of the shape of the reference sets. We compare the COA method to the weighted average of cluster centers (WACC) procedure in which the transformation is carried out based on the values of the cluster centers belonging to each of the reference membership functions instead of using the functions themselves. We show that this procedure is more effective and computationally much faster than the COA. The method is tested for a family of reference sets satisfying certain constraints, that is, for any support value the sum of reference membership function values equals one and the peak values of the two marginal membership functions project to the boundaries of the universe of discourse. For all the member sets of this family of reference sets the defuzzification errors do not get bigger as the linguistic variables tend to their extreme values. In addition, the more reference sets that are defined for a certain linguistic variable, the less the average defuzzification error becomes. In case of triangle shaped reference sets there is no defuzzification error at all. Finally, an alternative solution is provided that improves the performance of the COA method.

  18. Perturbative universal state-selective correction for state-specific multi-reference coupled cluster methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brabec, Jiri; Banik, Subrata; Kowalski, Karol

    2016-10-28

    The implementation details of the universal state-selective (USS) multi-reference coupled cluster (MRCC) formalism with singles and doubles (USS(2)) are discussed on the example of several benchmark systems. We demonstrate that the USS(2) formalism is capable of improving accuracies of state specific multi-reference coupled-cluster (MRCC) methods based on the Brillouin-Wigner and Mukherjee’s sufficiency conditions. Additionally, it is shown that the USS(2) approach significantly alleviates problems associated with the lack of invariance of MRCC theories upon the rotation of active orbitals. We also discuss the perturbative USS(2) formulations that significantly reduce numerical overhead of the full USS(2) method.

  19. System and method for calibrating inter-star-tracker misalignments in a stellar inertial attitude determination system

    NASA Technical Reports Server (NTRS)

    Li, Rongsheng (Inventor); Wu, Yeong-Wei Andy (Inventor); Hein, Douglas H. (Inventor)

    2004-01-01

    A method and apparatus for determining star tracker misalignments is disclosed. The method comprises the steps of defining a defining a reference frame for the star tracker assembly according to a boresight of the primary star tracker and a boresight of a second star tracker wherein the boresight of the primary star tracker and a plane spanned by the boresight of the primary star tracker and the boresight of the second star tracker at least partially define a datum for the reference frame for the star tracker assembly; and determining the misalignment of the at least one star tracker as a rotation of the defined reference frame.

  20. Determination of serum calcium levels by 42Ca isotope dilution inductively coupled plasma mass spectrometry.

    PubMed

    Han, Bingqing; Ge, Menglei; Zhao, Haijian; Yan, Ying; Zeng, Jie; Zhang, Tianjiao; Zhou, Weiyan; Zhang, Jiangtao; Wang, Jing; Zhang, Chuanbao

    2017-11-27

    Serum calcium level is an important clinical index that reflects pathophysiological states. However, detection accuracy in laboratory tests is not ideal; as such, a high accuracy method is needed. We developed a reference method for measuring serum calcium levels by isotope dilution inductively coupled plasma mass spectrometry (ID ICP-MS), using 42Ca as the enriched isotope. Serum was digested with 69% ultrapure nitric acid and diluted to a suitable concentration. The 44Ca/42Ca ratio was detected in H2 mode; spike concentration was calibrated by reverse IDMS using standard reference material (SRM) 3109a, and sample concentration was measured by a bracketing procedure. We compared the performance of ID ICP-MS with those of three other reference methods in China using the same serum and aqueous samples. The relative expanded uncertainty of the sample concentration was 0.414% (k=2). The range of repeatability (within-run imprecision), intermediate imprecision (between-run imprecision), and intra-laboratory imprecision were 0.12%-0.19%, 0.07%-0.09%, and 0.16%-0.17%, respectively, for two of the serum samples. SRM909bI, SRM909bII, SRM909c, and GBW09152 were found to be within the certified value interval, with mean relative bias values of 0.29%, -0.02%, 0.10%, and -0.19%, respectively. The range of recovery was 99.87%-100.37%. Results obtained by ID ICP-MS showed a better accuracy than and were highly correlated with those of other reference methods. ID ICP-MS is a simple and accurate candidate reference method for serum calcium measurement and can be used to establish and improve serum calcium reference system in China.

Top